WorldWideScience

Sample records for exterior doors roofs

  1. Project Overcoat - An Exploration of Exterior Insulation Strategies for 1-1/2-Story Roof Applications in Cold Climates

    Energy Technology Data Exchange (ETDEWEB)

    Ojczyk, Cindy [NorthernSTAR Building America Partnership, St. Paul, MN (United States); Mosiman, Garrett [NorthernSTAR Building America Partnership, St. Paul, MN (United States); Huelman, Pat [NorthernSTAR Building America Partnership, St. Paul, MN (United States); Schirber, Tom [NorthernSTAR Building America Partnership, St. Paul, MN (United States); Yost, Peter [NorthernSTAR Building America Partnership, St. Paul, MN (United States); Murry, Tessa [NorthernSTAR Building America Partnership, St. Paul, MN (United States)

    2013-04-01

    The development of an alternative method to interior-applied insulation strategies or exterior applied 'band-aids' such as heat tapes and ice belts may help reduce energy needs of millions of 1-1/2 story homes while reducing the risk of ice dam formation. A potential strategy for energy improvement of the roof is borrowed from new construction best practices: Here an 'overcoat' of a continuous air, moisture, and thermal barrier is applied on the outside of the roof structure for improved overall performance. The continuous insulation of this approach facilitates a reduction in thermal bridging which could further reduce energy consumption and bring existing homes closer to meeting the Building America goals for energy reduction. Research favors an exterior approach to deep energy retrofits and ice dam prevention in existing homes. The greatest amount of research focuses on whole house deep energy retrofits leaving a void in roof-only applications. The research is also void of data supporting the hygrothermal performance, durability, constructability, and cost of roof-only exterior overcoat strategies. Yet, contractors interviewed for this report indicate an understanding that exterior approaches are most promising for mitigating ice dams and energy loss and are able to sell these strategies to homeowners.

  2. 24 CFR 3285.801 - Exterior close-up.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Exterior close-up. 3285.801 Section... DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Exterior and Interior Close-Up § 3285.801 Exterior close-up. (a) Exterior siding and roofing necessary to join all sections of the home must be...

  3. Norwegian Pitched Roof Defects

    Directory of Open Access Journals (Sweden)

    Lars Gullbrekken

    2016-06-01

    Full Text Available The building constructions investigated in this work are pitched wooden roofs with exterior vertical drainpipes and wooden load-bearing system. The aim of this research is to further investigate the building defects of pitched wooden roofs and obtain an overview of typical roof defects. The work involves an analysis of the building defect archive from the research institute SINTEF Building and Infrastructure. The findings from the SINTEF archive show that moisture is a dominant exposure factor, especially in roof constructions. In pitched wooden roofs, more than half of the defects are caused by deficiencies in design, materials, or workmanship, where these deficiencies allow moisture from precipitation or indoor moisture into the structure. Hence, it is important to increase the focus on robust and durable solutions to avoid defects both from exterior and interior moisture sources in pitched wooden roofs. Proper design of interior ventilation and vapour retarders seem to be the main ways to control entry from interior moisture sources into attic and roof spaces.

  4. Measure Guideline: Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs

    Energy Technology Data Exchange (ETDEWEB)

    Loomis, H. [Building Science Corporation, Westford, MA (United States); Pettit, B. [Building Science Corporation, Westford, MA (United States)

    2015-05-01

    This Measure Guideline provides design and construction information for a deep energy enclosure retrofit (DEER) solution of a flat roof assembly. It describes the strategies and procedures for an exterior retrofit of a flat, wood-framed roof with brick masonry exterior walls, using exterior and interior (framing cavity) insulation. The approach supported in this guide could also be adapted for use with flat, wood-framed roofs with wood-framed exterior walls.

  5. Measure Guideline. Deep Energy Enclosure Retrofit for Zero Energy Ready House Flat Roofs

    Energy Technology Data Exchange (ETDEWEB)

    Loomis, H. [Building Science Corporation, Westford, MA (United States); Pettit, B. [Building Science Corporation, Westford, MA (United States)

    2015-05-29

    This Measure Guideline provides design and construction information for a deep energy enclosure retrofit solution of a flat roof assembly. It describes the strategies and procedures for an exterior retrofit of a flat wood-framed roof with brick masonry exterior walls using exterior and interior (framing cavity) insulation. The approach supported in this guide could also be adapted for use with flat wood-framed roofs with wood-framed exterior walls.

  6. Green roofs

    CSIR Research Space (South Africa)

    Van Wyk, Llewellyn V

    2010-04-01

    Full Text Available Green roofs are roofs that have been covered with a growing medium, creating a habitat on what would otherwise be a bland, lifeless surface. It is for this reason that green roofs are sometimes call 'vegetated' or 'living' roofs (Cantor 2008). A...

  7. Airtightness Results of Roof-Only Air Sealing Strategies on 1-1/2 Story Homes in Cold Climates

    Energy Technology Data Exchange (ETDEWEB)

    Ojczyk, C.; Murry, T.; Mosiman, G.

    2014-07-01

    In this second study on solutions to ice dams in 1-1/2 story homes, five test homes located in both cold and very cold climates were analyzed for air leakage reduction rates following modifications by independent contractors on owner-occupied homes. The reason for choosing this house type was they are very common in our area and very difficult to air seal and insulate effectively. Two projects followed a roof-only Exterior Thermal Moisture Management System (ETMMS) process. One project used an interior-only approach to roof air sealing and insulation. The remaining two projects used a deep energy retrofit approach for whole house (foundation wall, above grade wall, roof) air leakage and heat loss reduction. All were asked to provide information regarding project goals, process, and pre and post-blower door test results. Additional air leakage reduction data was provided by several NorthernSTAR Building America industry partners for interior-applied, roof-only modifications on 1-1/2 story homes. The data represents homes in the general market as well as homes that were part of the state of Minnesota weatherization program. A goal was to compare exterior air sealing methods with interior approaches. This pool of data enabled us to compare air tightness data from over 220 homes using similar air seal methods.

  8. Airtightness Results of Roof-Only Air Sealing Strategies on 1 ½-Story Homes in Cold Climates

    Energy Technology Data Exchange (ETDEWEB)

    Ojczyk, C.; Murry, T.; Mosiman, G.

    2014-07-01

    In this second study on solutions to ice dams in 1-1/2 story homes, the NorthernSTAR Building America Partnership team analyzed five test homes located in both cold and very cold climates for air leakage reduction rates following modifications by independent contractors on owner-occupied homes. These homes were chosen for testing as they are common in Minnesota and very difficult to air seal and insulate effectively. Two projects followed a roof-only Exterior Thermal Moisture Management System (ETMMS) process. One project used an interior-only approach to roof air sealing and insulation. The remaining two projects used a deep energy retrofit approach for whole house (foundation wall, above grade wall, roof) air leakage and heat loss reduction. All were asked to provide information regarding project goals, process, and pre and post-blower door test results. Additional air leakage reduction data was provided by several NorthernSTAR industry partners for interior-applied, roof-only modifications on 1-1/2 story homes. The data represents homes in the general market as well as homes that were part of the state of Minnesota weatherization program. A goal was to compare exterior air sealing methods with interior approaches. This pool of data enabled the team to compare air tightness data from over 220 homes using similar air seal methods.

  9. Spiders on a Hot Volcanic Roof: Colonisation Pathways and Phylogeography of the Canary Islands Endemic Trap-Door Spider Titanidiops canariensis (Araneae, Idiopidae.

    Directory of Open Access Journals (Sweden)

    Vera Opatova

    Full Text Available Studies conducted on volcanic islands have greatly contributed to our current understanding of how organisms diversify. The Canary Islands archipelago, located northwest of the coast of northern Africa, harbours a large number of endemic taxa. Because of their low vagility, mygalomorph spiders are usually absent from oceanic islands. The spider Titanidiops canariensis, which inhabits the easternmost islands of the archipelago, constitutes an exception to this rule. Here, we use a multi-locus approach that combines three mitochondrial and four nuclear genes to investigate the origins and phylogeography of this remarkable trap-door spider. We provide a timeframe for the colonisation of the Canary Islands using two alternative approaches: concatenation and species tree inference in a Bayesian relaxed clock framework. Additionally, we investigate the existence of cryptic species on the islands by means of a Bayesian multi-locus species delimitation method. Our results indicate that T. canariensis colonised the Canary Islands once, most likely during the Miocene, although discrepancies between the timeframes from different approaches make the exact timing uncertain. A complex evolutionary history for the species in the archipelago is revealed, which involves two independent colonisations of Fuerteventura from the ancestral range of T. canariensis in northern Lanzarote and a possible back colonisation of southern Lanzarote. The data further corroborate a previously proposed volcanic refugium, highlighting the impact of the dynamic volcanic history of the island on the phylogeographic patterns of the endemic taxa. T. canariensis includes at least two different species, one inhabiting the Jandia peninsula and central Fuerteventura and one spanning from central Fuerteventura to Lanzarote. Our data suggest that the extant northern African Titanidiops lineages may have expanded to the region after the islands were colonised and, hence, are not the source

  10. Generalized exterior algebras

    OpenAIRE

    Marchuk, Nikolay

    2011-01-01

    Exterior algebras and differential forms are widely used in many fields of modern mathematics and theoretical physics. In this paper we define a notion of $N$-metric exterior algebra, which depends on $N$ matrices of structure constants. The usual exterior algebra (Grassmann algebra) can be considered as 0-metric exterior algebra. Clifford algebra can be considered as 1-metric exterior algebra. $N$-metric exterior algebras for $N\\geq2$ can be considered as generalizations of the Grassmann alg...

  11. Roof assembly

    CSIR Research Space (South Africa)

    De Villiers, A

    2010-01-01

    Full Text Available The objective of this chapter is to provide sustainability criteria for roof system design that can be used by planners, designers and developers as a planning, design and development guide for sustainable building projects....

  12. Green Roofs

    Energy Technology Data Exchange (ETDEWEB)

    None

    2004-08-01

    A New Technology Demonstration Publication Green roofs can improve the energy performance of federal buildings, help manage stormwater, reduce airborne emissions, and mitigate the effects of urban heat islands.

  13. Generalized exterior algebras

    CERN Document Server

    Marchuk, Nikolay

    2011-01-01

    Exterior algebras and differential forms are widely used in many fields of modern mathematics and theoretical physics. In this paper we define a notion of $N$-metric exterior algebra, which depends on $N$ matrices of structure constants. The usual exterior algebra (Grassmann algebra) can be considered as 0-metric exterior algebra. Clifford algebra can be considered as 1-metric exterior algebra. $N$-metric exterior algebras for $N\\geq2$ can be considered as generalizations of the Grassmann algebra and Clifford algebra. Specialists consider models of gravity that based on a mathematical formalism with two metric tensors. We hope that the considered in this paper 2-metric exterior algebra can be useful for development of this model in gravitation theory. Especially in description of fermions in presence of a gravity field.

  14. Understanding Roofing Systems.

    Science.gov (United States)

    Michelsen, Ted

    2001-01-01

    Reviews the various types of multi- and single-ply roofing commonly used today in educational facilities. Roofing types described involve built-up systems, modified bitumen systems; ethylene propylene diene terpolymer roofs; and roofs of thermoplastic, metal, and foam. A description of the Roofing Industry Educational Institute is included. (GR)

  15. Simplified multizone blower door techniques for multifamily buildings. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-09-01

    This research focused on the applicability of (a) two-blower-door and (b) single-blower-door multi-zone pressurization techniques for estimating the air leakage characteristics of New York State multi-family apartment buildings. The research also investigated the magnitude of external leakage area in multi-family buildings and used computer simulations to estimate the effect of decreasing external and internal leakage areas on air infiltration rates. This research investigates whether two blower doors can be used to determine the ELA of the exterior envelope and the ELA of partitions. Two multi-zone versions of the single-blower-door pressurization method are also examined.

  16. Performance profiles of exterior fire protective building envelopes

    OpenAIRE

    2016-01-01

    The fire protective envelope of any building consists of multiple elements with widely differing properties relating to a fire, such as glass, roof tiles and sheathings, wood cladding, gaps and openings. Where resistance to an exterior fire is required, all elements should be verified to provide a comparable risk of burn-through. Elements are rated by either the material response to fire or fire resistance. In Europe, cladding sheets and wall membranes can be rated by K classes, which effecti...

  17. New roof element system

    DEFF Research Database (Denmark)

    Ditlev, Jesper; Rudbeck, Claus Christian

    1997-01-01

    The aim of the project has been to develop an element system for warm deck roofs which, from a thermal and economical point of view, can deal with the future demands for heat loss coefficients for low slope roofs.......The aim of the project has been to develop an element system for warm deck roofs which, from a thermal and economical point of view, can deal with the future demands for heat loss coefficients for low slope roofs....

  18. Renovation of Roof Structure

    DEFF Research Database (Denmark)

    Kjærbye, Per Oluf H

    1997-01-01

    A 30 year old not-watertight roof based on wooden boards with roofing felt have been changed to a pitched structure with cementos plates. At the same time more thermal insulation has been placed.......A 30 year old not-watertight roof based on wooden boards with roofing felt have been changed to a pitched structure with cementos plates. At the same time more thermal insulation has been placed....

  19. New roof element system

    DEFF Research Database (Denmark)

    Ditlev, Jesper; Rudbeck, Claus Christian

    1997-01-01

    The aim of the project has been to develop an element system for warm deck roofs which, from a thermal and economical point of view, can deal with the future demands for heat loss coefficients for low slope roofs.......The aim of the project has been to develop an element system for warm deck roofs which, from a thermal and economical point of view, can deal with the future demands for heat loss coefficients for low slope roofs....

  20. Green roof Malta

    OpenAIRE

    2015-01-01

    In Malta, buildings cover one third of the Island, leaving greenery in the dirt track. Green roofs are one way to bring plants back to urban areas with loads of benefits. Antoine Gatt, who manages the LifeMedGreenRoof project at the University of Malta, tells us more. http://www.um.edu.mt/think/green-roof-malta/

  1. EPA's Green Roof Research

    Science.gov (United States)

    This is a presentation on the basics of green roof technology. The presentation highlights some of the recent ORD research projects on green roofs and provices insight for the end user as to the benefits for green roof technology. It provides links to currently available EPA re...

  2. IMPROVED ROOF STABILIZATION TECHNOLOGIES

    Energy Technology Data Exchange (ETDEWEB)

    M.A. Ebadian, Ph.D.

    1999-01-01

    Many U.S. Department of Energy (DOE) remediation sites have performed roof repair and roof replacement to stabilize facilities prior to performing deactivation and decommissioning (D&D) activities. This project will review the decision criteria used by these DOE sites, along with the type of repair system used for each different roof type. Based on this information, along with that compiled from roofing experts, a decision-making tool will be generated to aid in selecting the proper roof repair systems. Where appropriate, innovative technologies will be reviewed and applied to the decision-making tool to determine their applicability. Based on the results, applied research and development will be conducted to develop a method to repair these existing roofing systems, while providing protection for the D and D worker in a cost-efficient manner.

  3. Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-Humid Climates

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, Kohta [National Renewable Energy Lab. (NREL), Golden, CO (United States); Lstiburek, Joseph W. [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-09-01

    Insulating roofs with dense-pack cellulose (instead of spray foam) has moisture risks, but is a lower cost approach. If moisture risks could be addressed, buildings could benefit from retrofit options, and the ability to bring HVAC systems within the conditioned space. Test houses with unvented roof assemblies were built to measure long-term moisture performance, in the Chicago area (5A) and the Houston area (2A). The Chicago-area test bed had seven experimental rafter bays, including a control vented compact roof, and six unvented roof variants with cellulose or fiberglass insulation. The interior was run at 50% RH. All roofs except the vented cathedral assembly experienced wood moisture contents and RH levels high enough to constitute failure. Disassembly at the end of the experiment showed that the unvented fiberglass roofs had wet sheathing and mold growth. In contrast, the cellulose roofs only had slight issues, such as rusted fasteners and sheathing grain raise. The Houston-area roof was an unvented attic insulated with spray-applied fiberglass. Most ridges and hips were built with a diffusion vent detail, capped with vapor permeable roof membrane. Some ridge sections were built as a conventional unvented roof, as a control. In the control unvented roofs, roof peak RHs reached high levels in the first winter; as exterior conditions warmed, RHs quickly fell. In contrast, the diffusion vent roofs had drier conditions at the roof peak in wintertime, but during the summer, RHs and MCs were higher than the unvented roof (albeit in the safe range).

  4. Collaborative active roof design

    NARCIS (Netherlands)

    Quanjel, E.M.C.J.

    2008-01-01

    Roofs play an essential role in buildings. Their value and impact often significantly surpass the cost ratio they represent in the total investment cost of the building. Traditionally, roofs have a protecting function and their basic design has changed little over hundreds of years. Nowadays

  5. Mine roof supports

    Energy Technology Data Exchange (ETDEWEB)

    Dettmers, M.; Peters, B.; Weirich, W.

    1983-12-27

    A mine roof support has hydraulic props mounted between a floor sill and a roof bar which can be raised and lowered by extension and retraction of the props. A goaf shield is pivotably connected to the rear of the roof bar and is linked via levers to the floor sill. A hydraulic piston and cylinder unit is connected between the roof bar and the goaf shield. Apparatus serves to prevent damage to the support components, and especially to the unit which could be extended beyond its full stroke when the props are retracted to bring the goaf shield and the roof bar more or less into alignment. The protective apparatus is composed of a compact valve device operated by a member, such as a cam, to block the props from hydraulic pressure when the goaf shield and the roof bar assume a pre-determined angular disposition. Both the valve device and its operating member are disposed in a protected position within chambers formed inside the roof bar and the goaf shield adjacent the pivot connection therebetween.

  6. Vee ziek door eikenprocessierups

    NARCIS (Netherlands)

    Spijker, J.H.

    2007-01-01

    In 2006 zijn er incidenteel ernstige problemen geweest met vee dat ingeschaard was langs eiken die zwaar waren aangetast door eikenprocessierups. Tot vele tientallen meters langs deze lanen bleek het gras niet geschikt voor dierlijke consumptie door de aanwezigheid van verwaaide nesten van deze rups

  7. Adaptable typologies for active roofs

    NARCIS (Netherlands)

    Quanjel, E.M.C.J.; Zeiler, W.

    2006-01-01

    The main objective of this part of the 6th framework Pan-European EUR-ACTIVE ROOF-er project is to improve the interaction between design participants of dynamic adaptable Active Roofs in product development and Active Roofs from an architects/ customers perspective. Improvements in Active Roof desi

  8. Green Roofs for Stormwater Management

    Science.gov (United States)

    This project evaluated green roofs as a stormwater management tool. Results indicate that the green roofs are capable of removing 40% of the annual rainfall volume from a roof through retention and evapotranspiration. Rainfall not retained by green roofs is detained, effectively...

  9. Effects of Solar Photovoltaic Panels on Roof Heat Transfer

    Science.gov (United States)

    Dominguez, A.; Klessl, J.; Samady, M.; Luvall, J. C.

    2010-01-01

    Building Heating, Ventilation and Air Conditioning (HVAC) is a major contributor to urban energy use. In single story buildings with large surface area such as warehouses most of the heat enters through the roof. A rooftop modification that has not been examined experimentally is solar photovoltaic (PV) arrays. In California alone, several GW in residential and commercial rooftop PV are approved or in the planning stages. With the PV solar conversion efficiency ranging from 5-20% and a typical installed PV solar reflectance of 16-27%, 53-79% of the solar energy heats the panel. Most of this heat is then either transferred to the atmosphere or the building underneath. Consequently solar PV has indirect effects on roof heat transfer. The effect of rooftop PV systems on the building roof and indoor energy balance as well as their economic impacts on building HVAC costs have not been investigated. Roof calculator models currently do not account for rooftop modifications such as PV arrays. In this study, we report extensive measurements of a building containing a flush mount and a tilted solar PV array as well as exposed reference roof. Exterior air and surface temperature, wind speed, and solar radiation were measured and thermal infrared (TIR) images of the interior ceiling were taken. We found that in daytime the ceiling surface temperature under the PV arrays was significantly cooler than under the exposed roof. The maximum difference of 2.5 C was observed at around 1800h, close to typical time of peak energy demand. Conversely at night, the ceiling temperature under the PV arrays was warmer, especially for the array mounted flat onto the roof. A one dimensional conductive heat flux model was used to calculate the temperature profile through the roof. The heat flux into the bottom layer was used as an estimate of the heat flux into the building. The mean daytime heat flux (1200-2000 PST) under the exposed roof in the model was 14.0 Watts per square meter larger than

  10. Green roofs; Les toitures vegetalisees

    Energy Technology Data Exchange (ETDEWEB)

    Seghier, C.

    2006-03-15

    Impervious surface coverage keeps spreading in cities. Streets, sidewalks, parking lots and roofs are waterproof, meaning greater amounts of water to channel and treat and higher flood risks during heavy rainfalls. Green roofing can play a key part in addressing this alarming issue. There are three types of green roofs: extensive, semi-intensive and intensive. The extensive green roof technique uses a thin soil covering with a variety of species providing year-round plant coverage. The plants are not necessarily horticultural in which case routine maintenance is minimal. No watering is needed. Usually extensive green roofs create an ecosystem. The semi-intensive green roof technique uses a soil covering of average thickness and serves to create decorative roofing. Although maintenance is moderate, watering is essential. The intensive green roof technique produces a terrace roof garden. Another advantage of green roofs is they increase the life cycle of the sealing. Roof sealing protection may see the span of its life cycle, now at about fifteen years, doubled if the building has a green roof. planning professionals still know very little about green roofing solutions. Yet, green roofing provides unquestionable ecological qualities and thermal and acoustic performance that have proven to be environmentally friendly. Yet France lags behind northern European countries in green roofing. The Germans, Swiss, Austrians, Scandinavians and Dutch have been using the technique for more than twenty years. (A.L.B.)

  11. Exterior dimension of fat fractals

    Science.gov (United States)

    Grebogi, C.; Mcdonald, S. W.; Ott, E.; Yorke, J. A.

    1985-01-01

    Geometric scaling properties of fat fractal sets (fractals with finite volume) are discussed and characterized via the introduction of a new dimension-like quantity which is called the exterior dimension. In addition, it is shown that the exterior dimension is related to the 'uncertainty exponent' previously used in studies of fractal basin boundaries, and it is shown how this connection can be exploited to determine the exterior dimension. Three illustrative applications are described, two in nonlinear dynamics and one dealing with blood flow in the body. Possible relevance to porous materials and ballistic driven aggregation is also noted.

  12. Stop Sagging Doors.

    Science.gov (United States)

    Cronk, Bob

    2000-01-01

    Explains how continuous geared hinges can help prevent doors from pulling away from their frames and can last as long as 20 years with little maintenance. Descriptions of three main applications for continuous geared hinges are described. (GR)

  13. Thermal Performance of Building Roof with Infrared Reflective Coatings

    Institute of Scientific and Technical Information of China (English)

    SHEN Hui; TAN Hong-wei; KATSUO MIKI; LIU Xiao-yu

    2009-01-01

    This paper investigated the applicability and effects of infrared reflective coating on energy con-sumption of factory building in hot summer and warm winter zone. It first resorted to theoretical calculation, which demonstrated the beneficial effects of infrared reflective coating on reducing building energy consumption. Then it analyzed a field measurement done on two identical rooms respectively with ordinary coated roof and in-frared reflective coated roof from November 2006 to October 2007, on a 24h basis. The measured data include exterior and interior roof surface temperature, indoor air temperature, and indoor globe temperature. The relat-ed weather data is from a weather station near the measured area. The continuous measurement has been accom-plished in southern China, and the measured data indicate that roof surface temperature and heat gain are signifi-cantly decreased in summer while slight negative effects in winter are induced by adopting infrared reflective coating. Thus it is simple and applicable to reduce building energy consumption in this area by applying infrared reflective coating. Regress equation between reduced roof thermal property, such as surface temperature and heat gain, and reduction in absorbed solar radiation shows their highly linear relationship. Based on the mea-sured data, it is estimated that the reduced power consumption is 3.45 kWh/m2·month in June.

  14. Building America Case Study: Field Testing an Unvented Roof with Asphalt Shingles in a Cold Climate, Boilingbrook, Illinois

    Energy Technology Data Exchange (ETDEWEB)

    2015-09-01

    Insulating roofs with dense-pack cellulose (instead of spray foam) has moisture risks, but is a lower cost approach. If moisture risks could be addressed, buildings could benefit from retrofit options, and the ability to bring HVAC systems within the conditioned space. Test houses with unvented roof assemblies were built to measure long-term moisture performance, in the Chicago area (5A) and the Houston area (2A). The Chicago-area test bed had seven experimental rafter bays, including a 'control' vented compact roof, and six unvented roof variants with cellulose or fiberglass insulation. The interior was run at 50% RH. All roofs except the vented cathedral assembly experienced wood moisture contents and RH levels high enough to constitute failure. Disassembly at the end of the experiment showed that the unvented fiberglass roofs had wet sheathing and mold growth. In contrast, the cellulose roofs only had slight issues, such as rusted fasteners and sheathing grain raise. The Houston-area roof was an unvented attic insulated with spray-applied fiberglass. Most ridges and hips were built with a 'diffusion vent' detail, capped with vapor permeable roof membrane. Some ridge sections were built as a conventional unvented roof, as a control. In the control unvented roofs, roof peak RHs reached high levels in the first winter; as exterior conditions warmed, RHs quickly fell. In contrast, the diffusion vent roofs had drier conditions at the roof peak in wintertime, but during the summer, RHs and MCs were higher than the unvented roof (albeit in the safe range).

  15. Green Roofs for Stormwater Runoff Control - Abstract

    Science.gov (United States)

    This project evaluated green roofs as a stormwater management tool. Specifically, runoff quantity and quality from green and flat asphalt roofs were compared. Evapotranspiration from planted green roofs and evaporation from unplanted media roofs were also compared. The influence...

  16. Evolution of Flat Roofs

    Directory of Open Access Journals (Sweden)

    Şt. Vasiliu

    2009-01-01

    Full Text Available Roofs are constructive subassembles that are located at the top of buildings, which toghether with perimetral walls and some elements of the infrastructure belongs to the subsystem elements that close the building. Roofs must meet resistance requirements to mechanical action, thermal insulating, waterproofing and acoustic, fire resistance, durability, economy and aesthetics. The man saw the need to build roofs from the oldest ancient times. Even if the design of buildings has an empirical character, are known and are preserved until today constructions that are made in antiquity, by the Egyptians, Greeks and Romans with architectural achievements, worthy of admiration and in present time. General composition of civil construction has been influenced throughout the evolution of construction history by the level of production forces and properties of building materials available in every historical epoch. For over five millennia, building materials were stone, wood and ceramic products (concrete was used by theRomans only as filling material.

  17. Design methodology for innovative roofs

    NARCIS (Netherlands)

    Quanjel, E.M.C.J.; Zeiler, W.; Trum, H.M.G.J.

    2006-01-01

    Traditional roofs have primary, passive, functions such as protection against rain, wind, snow etc.. Nowadays, roofs are increasingly used as preferred location for additional functions such as photovoltaic systems, roof lights and safety devices. New approaches, on designing as well as assembling t

  18. Comparative analysis of urethane-alkyd and water based coatings for exterior wood

    OpenAIRE

    Jaić, Milan

    2012-01-01

    The protection of wood elements in the exterior use, such as window frames and doors, can be performed with various type of coatings. The most diffused in use are conventional coatings – solvent-based (alkyd, modified alkyds etc.). Last years, because of the restrictive normative regarding the solvent emission, the trend of coatings development leads to the reduction of volatile organic components. Organic solvents are reduced or substituted by environmentally safer solvents such as water or ...

  19. Performance profiles of exterior fire protective building envelopes

    Directory of Open Access Journals (Sweden)

    Jarnskjold Tobias

    2016-01-01

    Full Text Available The fire protective envelope of any building consists of multiple elements with widely differing properties relating to a fire, such as glass, roof tiles and sheathings, wood cladding, gaps and openings. Where resistance to an exterior fire is required, all elements should be verified to provide a comparable risk of burn-through. Elements are rated by either the material response to fire or fire resistance. In Europe, cladding sheets and wall membranes can be rated by K classes, which effectively include a measure of the time to burn through. A determination of burn-through time of each element of a specific building envelope should be obtained. A design tool to verify the performance of a building's fire protective envelope has been developed. In this paper, a general description of passive elements of the envelope, which should be included in a risk assessment tool such as an index method, is presented. An illustrative approach to visualise the profiles for areas densely spaced structures where an exterior fire may trigger building-to-building fire spread is also included. The research is based on the hypothesis that a relatively subtle and pointed upgrading of an exterior building envelope will severely reduce the speed of building-to-building fire spread, thus allowing firefighting efforts to get on top of the situation. For a burning structure to expose other buildings to fire, the fire has to settle, which leads to a burn-through to the inside. Once inside, an enclosure fire needs to develop and burn through the roof or break one or more large window panes. It is estimated that a 5–10 min delay for a structure to expose other structures to fire can be sufficient to avoid loss of multiple structures. A 10–50 min burn-through time allows for an extended intervention by the fire brigade, which is significant in rural areas. A fire protective envelope may prevent an exterior fire from penetrating the protective envelope at all and the

  20. Producing superhydrophobic roof tiles

    Science.gov (United States)

    Carrascosa, Luis A. M.; Facio, Dario S.; Mosquera, Maria J.

    2016-03-01

    Superhydrophobic materials can find promising applications in the field of building. However, their application has been very limited because the synthesis routes involve tedious processes, preventing large-scale application. A second drawback is related to their short-term life under outdoor conditions. A simple and low-cost synthesis route for producing superhydrophobic surfaces on building materials is developed and their effectiveness and their durability on clay roof tiles are evaluated. Specifically, an organic-inorganic hybrid gel containing silica nanoparticles is produced. The nanoparticles create a densely packed coating on the roof tile surface in which air is trapped. This roughness produces a Cassie-Baxter regime, promoting superhydrophobicity. A surfactant, n-octylamine, was also added to the starting sol to catalyze the sol-gel process and to coarsen the pore structure of the gel network, preventing cracking. The application of ultrasound obviates the need to use volatile organic compounds in the synthesis, thereby making a ‘green’ product. It was also demonstrated that a co-condensation process effective between the organic and inorganic species is crucial to obtain durable and effective coatings. After an aging test, high hydrophobicity was maintained and water absorption was completely prevented for the roof tile samples under study. However, a transition from a Cassie-Baxter to a Wenzel state regime was observed as a consequence of the increase in the distance between the roughness pitches produced by the aging of the coating.

  1. Stormwater Attenuation by Green Roofs

    Science.gov (United States)

    Sims, A.; O'Carroll, D. M.; Robinson, C. E.; Smart, C. C.

    2014-12-01

    Innovative municipal stormwater management technologies are urgently required in urban centers. Inadequate stormwater management can lead to excessive flooding, channel erosion, decreased stream baseflows, and degraded water quality. A major source of urban stormwater is unused roof space. Green roofs can be used as a stormwater management tool to reduce roof generated stormwater and generally improve the quality of runoff. With recent legislation in some North American cities, including Toronto, requiring the installation of green roofs on large buildings, research on the effectiveness of green roofs for stormwater management is important. This study aims to assess the hydrologic response of an extensive sedum green roof in London, Ontario, with emphasis on the response to large precipitation events that stress municipal stormwater infrastructure. A green roof rapidly reaches field capacity during large storm events and can show significantly different behavior before and after field capacity. At field capacity a green roof has no capillary storage left for retention of stormwater, but may still be an effective tool to attenuate peak runoff rates by transport through the green roof substrate. The attenuation of green roofs after field capacity is linked to gravity storage, where gravity storage is the water that is temporarily stored and can drain freely over time after field capacity has been established. Stormwater attenuation of a modular experimental green roof is determined from water balance calculations at 1-minute intervals. Data is used to evaluate green roof attenuation and the impact of field capacity on peak flow rates and gravity storage. In addition, a numerical model is used to simulate event based stormwater attenuation. This model is based off of the Richards equation and supporting theory of multiphase flow through porous media.

  2. Humble Opinion of Roof Gardens

    Institute of Scientific and Technical Information of China (English)

    WANGXiaoxiao; MAQiangqiang; CAOXiaojun

    2005-01-01

    With the swift development of urban construction in China and the boost in people's demands for green environments in cities, roof gardens are widely used as a new way of greening. This paper deals chiefly with the functions, building principle, classification and composing elements of roof gardens, an analysis of main ecological factors, loads, and waterproof. It suggests that roof gardens will bring about a comparatively big leap in city greening both quantitatively and qualitatively.

  3. Green roofs: potential at LANL

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco, Elena M [Los Alamos National Laboratory

    2009-01-01

    Green roofs, roof systems that support vegetation, are rapidly becoming one of the most popular sustainable methods to combat urban environmental problems in North America. An extensive list of literature has been published in the past three decades recording the ecological benefits of green roofs; and now those benefits have been measured in enumerated data as a means to analyze the costs and returns of green roof technology. Most recently several studies have made substantial progress quantifying the monetary savings associated with storm water mitigation, the lessoning of the Urban Heat Island, and reduction of building cooling demands due to the implementation of green roof systems. Like any natural vegetation, a green roof is capable of absorbing the precipitation that falls on it. This capability has shown to significantly decrease the amount of storm water runoff produced by buildings as well as slow the rate at which runoff is dispensed. As a result of this reduction in volume and velocity, storm drains and sewage systems are relieved of any excess stress they might experience in a storm. For many municipalities and private building owners, any increase in storm water mitigation can result in major tax incentives and revenue that does not have to be spent on extra water treatments. Along with absorption of water, vegetation on green roofs is also capable of transpiration, the process by which moisture is evaporated into the air to cool ambient temperatures. This natural process aims to minimize the Urban Heat Island Effect, a phenomenon brought on by the dark and paved surfaces that increases air temperatures in urban cores. As the sun distributes solar radiation over a city's area, dark surfaces such as bitumen rooftops absorb solar rays and their heat. That heat is later released during the evening hours and the ambient temperatures do not cool as they normally would, creating an island of constant heat. Such excessively high temperatures induce heat

  4. A Door-to-Door Combined Transport Planner

    DEFF Research Database (Denmark)

    Aastrup, Jesper; Jespersen, Per Homann; Pedersen, Michael B.

    2004-01-01

    Establishing a web-based portal functioning as a one-stop-shop for transport buyers is a radical idea of a consumer oriented intermodal freight system. This utopian vision will be materialized in a system description and a prototype of a Door-to-Door Combined Trans-port Planner (COTRAP), developed...

  5. A School on Roof

    Institute of Scientific and Technical Information of China (English)

    ZhouChao

    2005-01-01

    March 23, Wednesday, Wuhan. It was a raining and cloudy day. One month passed but still more than 20 students had yet registered in Lingzhi Elementary School in Jianghan District, Wuhan, capital city of central Hubei Province. Zhu Zhongfan habitually looked out to the stairway of the building. “Whenever a new semester begins, a dozen of students will not come. They either go back to their hometowns or transfer to other school or even drop out.” Zhu, 49 years old, is the headmaster of the school. He began teaching at 19 and founded this school in 1999. Currently, there are 406 registered students, most of which are children of migrant workers from the countryside. As it is extremely hard to find a cheap place for school, Zhu had to locate his school on the roof of a vegetable fair building. Everyday, student's reciting of textbooks mixes with shouting of vendors, orchestrating unique symphonic melodies.

  6. Sustainable roofs with real energy savings

    Energy Technology Data Exchange (ETDEWEB)

    Christian, J.E.; Petrie, T.W.

    1996-12-31

    This paper addresses the general concept of sustainability and relates it to the building owner`s selection of a low-slope roof. It offers a list of performance features of sustainable roofs. Experiences and data relevant to these features for four unique roofs are then presented which include: self-drying systems, low total equivalent warming foam insulation, roof coatings and green roofs. The paper concludes with a list of sustainable roofing features worth considering for a low-slope roof investment. Building owners and community developers are showing more interest in investing in sustainability. The potential exists to design, construct, and maintain roofs that last twice as long and reduce the building space heating and cooling energy loads resulting from the roof by 50% (based on the current predominant design of a 10-year life and a single layer of 1 to 2 in. (2.5 to 5.1 cm) of insulation). The opportunity to provide better low-slope roofs and sell more roof maintenance service is escalating. The general trend of outsourcing services could lead to roofing companies` owning the roofs they install while the traditional building owner owns the rest of the building. Such a situation would have a very desirable potential to internalize the costs of poor roof maintenance practices and high roof waste disposal costs, and to offer a profit for installing roofs that are more sustainable. 14 refs., 12 figs.

  7. Green Roofs for Stormwater Runoff Control

    Science.gov (United States)

    This project evaluated green roofs as a stormwater management tool. Specifically, runoff quantity and quality from green and flat asphalt roofs were compared. Evapotranspiration from planted green roofs and evaporation from unplanted media roofs were also compared. The influence...

  8. Sustainable roofs with real energy savings

    Energy Technology Data Exchange (ETDEWEB)

    Christian, J.E.; Petrie, T.W.

    1996-12-31

    This paper addresses the general concept of sustainability and relates it to the building owner`s selection of a low-slope roof. It offers a list of performance features of sustainable roofs. Experiences and data relevant to these features for four unique roofs are then presented which include: self-drying systems, low total equivalent warming foam insulation, roof coatings and green roofs. The paper concludes with a list of sustainable roofing features worth considering for a low-slope roof investment. Building owners and community developers are showing more interest in investing in sustainability. The potential exists to design, construct, and maintain roofs that last twice as long and reduce the building space heating and cooling energy loads resulting from the roof by 50% (based on the current predominant design of a 10-year life and a single layer of 1 to 2 in. (2.5 to 5.1 cm) of insulation). The opportunity to provide better low-slope roofs and sell more roof maintenance service is escalating. The general trend of outsourcing services could lead to roofing companies` owning the roofs they install while the traditional building owner owns the rest of the building. Such a situation would have a very desirable potential to internalize the costs of poor roof maintenance practices and high roof waste disposal costs, and to offer a profit for installing roofs that are more sustainable. 14 refs., 12 figs.

  9. 30 CFR 75.205 - Installation of roof support using mining machines with integral roof bolters.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Installation of roof support using mining machines with integral roof bolters. 75.205 Section 75.205 Mineral Resources MINE SAFETY AND HEALTH... Roof Support § 75.205 Installation of roof support using mining machines with integral roof bolters...

  10. Evaluation of energy roof direct utilization

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, R.; Rossetto, L.; Viero, L.

    1984-04-01

    Energy roofs are roofing systems equipped with channels which allow both solar and atmospheric energy collection. They were conceived as cold source for heat pump systems. The behavious of an energy roof in DHW direct heating was studied; this might extend energy roof utilization all year long. The estimates were performed through more reliable recently proposed correlations for wind convection heat transfer coefficients. The advantage of annual energy roof utilization in DHW direct heating is predictable.

  11. Advanced Energy Efficient Roof System

    Energy Technology Data Exchange (ETDEWEB)

    Jane Davidson

    2008-09-30

    Energy consumption in buildings represents 40 percent of primary U.S. energy consumption, split almost equally between residential (22%) and commercial (18%) buildings.1 Space heating (31%) and cooling (12%) account for approximately 9 quadrillion Btu. Improvements in the building envelope can have a significant impact on reducing energy consumption. Thermal losses (or gains) from the roof make up 14 percent of the building component energy load. Infiltration through the building envelope, including the roof, accounts for an additional 28 percent of the heating loads and 16 percent of the cooling loads. These figures provide a strong incentive to develop and implement more energy efficient roof systems. The roof is perhaps the most challenging component of the building envelope to change for many reasons. The engineered roof truss, which has been around since 1956, is relatively low cost and is the industry standard. The roof has multiple functions. A typical wood frame home lasts a long time. Building codes vary across the country. Customer and trade acceptance of new building products and materials may impede market penetration. The energy savings of a new roof system must be balanced with other requirements such as first and life-cycle costs, durability, appearance, and ease of construction. Conventional residential roof construction utilizes closely spaced roof trusses supporting a layer of sheathing and roofing materials. Gypsum board is typically attached to the lower chord of the trusses forming the finished ceiling for the occupied space. Often in warmer climates, the HVAC system and ducts are placed in the unconditioned and otherwise unusable attic. High temperature differentials and leaky ducts result in thermal losses. Penetrations through the ceilings are notoriously difficult to seal and lead to moisture and air infiltration. These issues all contribute to greater energy use and have led builders to consider construction of a conditioned attic. The

  12. Exterior Powers of Symmetric Bilinear Forms

    Institute of Scientific and Technical Information of China (English)

    Seán McGarraghy

    2002-01-01

    We study exterior powers of classes of symmetric bilinear forms in the Witt-Grothendieck ring of a field of characteristic not equal to 2, and derive their basic properties. The exterior powers are used to obtain annihilating polynomials for quadratic forms in the Witt ring.

  13. Japón: sector exterior

    OpenAIRE

    Pelegrín Solé, Ángeles

    2008-01-01

    Introducción al comercio exterior, al análisis de los principales sectores importadores y exportadores. Evolución de la inversión directa de Japón en el exterior. Análisis de la distribución geográfica y sectorial.

  14. [A review of green roof performance towards management of roof runoff].

    Science.gov (United States)

    Chen, Xiao-ping; Huang, Pei; Zhou, Zhi-xiang; Gao, Chi

    2015-08-01

    Green roof has a significant influence on reducing runoff volume, delaying runoff-yielding time, reducing the peak flow and improving runoff quality. This paper addressed the related research around the world and concluded from several aspects, i.e., the definition of green roof of different types, the mechanism how green roof manages runoff quantity and quality, the ability how green roof controls roof runoff, and the influence factors of green roof toward runoff quantity and quality. Afterwards, there was a need for more future work on research of green roof toward roof runoff, i.e., vegetation selection of green roof, efficient construction model selection of green roof, the regulating characteristics of green roof on roof runoff, the value assessment of green roof on roof runoff, analysis of source-sink function of green roof on the water pollutants of roof runoff and the research on the mitigation measures of roof runoff pollution. This paper provided a guideline to develop green roofs aiming to regulating roof runoff.

  15. Hydrological Performance of Green Roofs

    OpenAIRE

    Poorova, Zuzana; Vranayova, Zuzana

    2015-01-01

    There should be a balance between artificial environment and natural environment. As forests, fields, gardens and urban lands are being replaced with bituminous, concrete and unnatural surfaces, necessity of recovering green and blue spaces and natural areas is becoming more and more critical. Green roof is a tool in strategy of making more pervious areas and beating more impervious areas. Green roof is lately becoming part of urban storm water management. Considering this fact, new construct...

  16. China opens the door

    Energy Technology Data Exchange (ETDEWEB)

    Starke, K.

    1997-01-01

    The door to China`s vast market for power generation was opened a bit further for foreign firms in November. That is when power ministry head Shi Dazhen said the country would rely on overseas investors for 20 percent of the funding needed to boost output--double the amount foreigners were previously allowed to contribute. Through 1995, foreigners invested $12.2 billion in China`s electricity industry, accounting for 10 percent of total investment. According to Shi, foreign investors will be asked to provide about $17 billion of the $84 billion China plans to invest in the sector over the next five years. Under China`s Ninth Five-Year Plan (1996-2000), the government aims to boost the country`s power generation capacity at the rate of 15,000 MW to 20,000 MW annually by the year 2000. Since China`s public external debt balance already exceeds $80 billion, however, the government would seem to have little choice but to allow foreigners a greater role. Shi also said that foreigners would be allowed 100 percent ownership of PRC power projects. This is discouraged under China`s current industry guidelines. It is, however, expected to be permitted under China`s first build-operate-transfer (BOT) law, which was anticipated by the end of 1996, says Susan Urkevich, director of project finance at HSBC Investment Bank Asia in Hong Kong. Indeed, China`s first BOT is already happening.

  17. Genetics Home Reference: DOORS syndrome

    Science.gov (United States)

    ... do not have all of these features. Most people with DOORS syndrome have profound hearing loss caused by changes in the inner ears (sensorineural deafness). Developmental delay and intellectual disability are also often severe in this disorder. The ...

  18. 14 CFR 23.783 - Doors.

    Science.gov (United States)

    2010-01-01

    ... may be crowded against the door on the inside of the airplane. (2) If inward opening doors are used, there must be a means to prevent occupants from crowding against the door to the extent that would... the external door, for which the initial opening movement is not inward, is fully closed and...

  19. Performance Analysis of Cool Roof, Green Roof and Thermal Insulation on a Concrete Flat Roof in Tropical Climate

    OpenAIRE

    Zingre, Kishor T.; Yang, Xingguo; Wan, Man Pun

    2015-01-01

    In the tropics, the earth surface receives abundant solar radiation throughout the year contributing significantly to building heat gain and, thus, cooling demand. An effective method that can curb the heat gains through opaque roof surfaces could provide significant energy savings. This study investigates and compares the effectiveness of various passive cooling techniques including cool roof, green roof and thermal insulation for reducing the heat gain through a flat concrete roof in tropic...

  20. Advanced Energy Efficient Roof System

    Energy Technology Data Exchange (ETDEWEB)

    Jane Davidson

    2008-09-30

    Energy consumption in buildings represents 40 percent of primary U.S. energy consumption, split almost equally between residential (22%) and commercial (18%) buildings.1 Space heating (31%) and cooling (12%) account for approximately 9 quadrillion Btu. Improvements in the building envelope can have a significant impact on reducing energy consumption. Thermal losses (or gains) from the roof make up 14 percent of the building component energy load. Infiltration through the building envelope, including the roof, accounts for an additional 28 percent of the heating loads and 16 percent of the cooling loads. These figures provide a strong incentive to develop and implement more energy efficient roof systems. The roof is perhaps the most challenging component of the building envelope to change for many reasons. The engineered roof truss, which has been around since 1956, is relatively low cost and is the industry standard. The roof has multiple functions. A typical wood frame home lasts a long time. Building codes vary across the country. Customer and trade acceptance of new building products and materials may impede market penetration. The energy savings of a new roof system must be balanced with other requirements such as first and life-cycle costs, durability, appearance, and ease of construction. Conventional residential roof construction utilizes closely spaced roof trusses supporting a layer of sheathing and roofing materials. Gypsum board is typically attached to the lower chord of the trusses forming the finished ceiling for the occupied space. Often in warmer climates, the HVAC system and ducts are placed in the unconditioned and otherwise unusable attic. High temperature differentials and leaky ducts result in thermal losses. Penetrations through the ceilings are notoriously difficult to seal and lead to moisture and air infiltration. These issues all contribute to greater energy use and have led builders to consider construction of a conditioned attic. The

  1. A primer on exterior differential calculus

    Directory of Open Access Journals (Sweden)

    Burton D.A.

    2003-01-01

    Full Text Available A pedagogical application-oriented introduction to the cal­culus of exterior differential forms on differential manifolds is presented. Stokes' theorem, the Lie derivative, linear con­nections and their curvature, torsion and non-metricity are discussed. Numerous examples using differential calculus are given and some detailed comparisons are made with their tradi­tional vector counterparts. In particular, vector calculus on R3 is cast in terms of exterior calculus and the traditional Stokes' and divergence theorems replaced by the more powerful exterior expression of Stokes' theorem. Examples from classical continuum mechanics and spacetime physics are discussed and worked through using the language of exterior forms. The numerous advantages of this calculus, over more traditional ma­chinery, are stressed throughout the article. .

  2. Sloped Roof Conversions for Small, Flat-Roof Buildings.

    Science.gov (United States)

    1984-12-01

    co solve other, unrelated Table 5 List of Contacts Involved in Roof Conversion Projects California AEP-Span, San Diego Florida Duval County...Survlvablllty Section, CCB-CPS Infrastructure Branch, LANDA HQ UsaUCOH 09128 ATTN: ECJ 4/7-LOE Fort Belvoir, VA 22060 (7) ATTN

  3. Green Roof Potential in Arab Cities

    OpenAIRE

    Attia, Shady

    2014-01-01

    Urban green roofs have long been promoted as an easy and effective strategy for beautifying the built environment and increasing investment opportunity. The building roof is very important because it has a direct impact on thermal comfort and energy conservation in and around buildings. Urban green roofs can help to address the lack of green space in many urban areas. Urban green roofs provides the city with open spaces that helps reduce urban heat island effect and provides the human populat...

  4. GREEN ROOFS — A GROWING TREND

    Science.gov (United States)

    One of the most interesting stormwater control systems under evaluation by EPA are “green roofs”. Green roofs are vegetative covers applied to building roofs to slow, or totally absorb, rainfall runoff during storms. While the concept of over-planted roofs is very ancient, the go...

  5. A Door-to-Door Combined Transport Planner

    DEFF Research Database (Denmark)

    Aastrup, Jesper; Jespersen, Per Homann; Pedersen, Michael B.

    2004-01-01

    Establishing a web-based portal functioning as a one-stop-shop for transport buyers is a radical idea of a consumer oriented intermodal freight system. This utopian vision will be materialized in a system description and a prototype of a Door-to-Door Combined Trans-port Planner (COTRAP), develope......- and inter-organizational barriers to the establishment of a competitive and effective combined transport system with rail freight operators as the intermodal integrator. In this paper we describes the ideas and methodology behind the project, as well as some preliminary results....

  6. Evaluation of Roof Bolting Requirements Based on In-Mine Roof Bolter Drilling

    Energy Technology Data Exchange (ETDEWEB)

    Syd S. Peng

    2005-10-01

    Roof bolting is the most popular method for underground openings in the mining industry, especially in the bedded deposits such as coal. In fact, all U.S. underground coal mine entries are roof-bolted as required by law. However, roof falls still occur frequently in the roof bolted entries. The two possible reasons are: the lack of knowledge of and technology to detect the roof geological conditions in advance of mining, and lack of roof bolting design criteria for modern roof bolting systems. This research is to develop a method for predicting the roof geology and stability condition in real time during roof bolting operation. Based on this information, roof bolting design criteria for modern roof bolting systems will be developed for implementation in real time. For the prediction of roof geology and stability condition in real time, a micro processor was used and a program developed to monitor and record the drilling parameters of roof bolter. These parameters include feed pressure, feed flow (penetration rate), rotation pressure, rotation rate, vacuum pressure, oil temperature of hydraulic circuit, and signals for controlling machine. From the results of a series of laboratory and underground tests so far, feed pressure is found to be a good indicator for identifying the voids/fractures and estimating the roof rock strength. The method for determining quantitatively the location and the size of void/fracture and estimating the roof rock strength from the drilling parameters of roof bolter was developed. Also, a set of computational rules has been developed for in-mine roof using measured roof drilling parameters and implemented in MRGIS (Mine Roof Geology Information System), a software package developed to allow mine engineers to make use of the large amount of roof drilling parameters for predicting roof geology properties automatically. For the development of roof bolting criteria, finite element models were developed for tensioned and fully grouted bolting

  7. Simulation of the noise transmission through automotive door seals

    CERN Document Server

    Hazir, Andreas

    2016-01-01

    Andreas Hazir is investigating the door seal contribution to the interior noise level of production vehicles. These investigations contain experimental contribution analyses of real production vehicles and of academic test cases as well as the development of a simulation methodology for noise transmission through sealing systems and side windows. The simulations are realized by coupling transient computational aeroacoustics of the exterior flow to nonlinear finite element simulations of the structural transmission. By introducing a linear transmission model, the setup and computational costs of the seal noise transmission are significantly reduced, resulting in the feasibility of numerical contribution analyses of real production vehicles. Contents Contribution Analyses of Production Vehicles Acoustic Excitation versus Aeroacoustic Excitation Development of a Simulation Methodology Sensitivity Analysis of Noise Transmission Simulations Target Groups Researchers and students in the field of automotive engineer...

  8. The Girl on the Roof

    Institute of Scientific and Technical Information of China (English)

    刘晓宁; 邓彬

    2003-01-01

    One day when the sun was shin-ning and Jillian's office at the BBCwas getting warm,she had one of her ideas."I'll go up ontothe roof after lunch,"she thought,"andsunbathe(日光浴).I've been working hard

  9. PREDICTING THERMAL PERFORMANCE OF ROOFING SYSTEMS IN SURABAYA

    Directory of Open Access Journals (Sweden)

    MINTOROGO Danny Santoso

    2015-07-01

    Full Text Available Traditional roofing systems in the developing country likes Indonesia are still be dominated by the 30o, 45o, and more pitched angle roofs; the roofing cover materials are widely used to traditional clay roof tiles, then modern concrete roof tiles, and ceramic roof tiles. In the 90’s decay, shop houses are prosperous built with flat concrete roofs dominant. Green roofs and roof ponds are almost rarely built to meet the sustainable environmental issues. Some tested various roof systems in Surabaya were carried out to observe the roof thermal performances. Mathematical equation model from three references are also performed in order to compare with the real project tested. Calculated with equation (Kabre et al., the 30o pitched concrete-roof-tile, 30o clay-roof-tile, 45o pitched concrete-roof-tile are the worst thermal heat flux coming to room respectively. In contrast, the bare soil concrete roof and roof pond system are the least heat flux streamed onto room. Based on predicted calculation without insulation and cross-ventilation attic space, the roof pond and bare soil concrete roof (greenery roof are the appropriate roof systems for the Surabaya’s climate; meanwhile the most un-recommended roof is pitched 30o or 45o angle with concrete-roof tiles roofing systems.

  10. Hydrological Response of Sedum-Moss Roof

    Science.gov (United States)

    Bengtsson, L.

    2004-12-01

    Eco-roofs are becoming popular for aesthetic reasons and also as units of stormwater systems. It is thought that such roofs with soil cover and vegetation reduces the total runoff, the peak flows and improves the quality of the roof water. Here are reported investigations of runoff from thin, 3-4 cm soil, extensive green roofs with sedum-moss in southern Sweden. The two-year study was performed on new roofs in the eco-city Augustenborg and also on nearby old vegetative roofs. The rain intensity and the roof runoff were measured with 5 min, or in some experiments with 1 min, resolution. The annual runoff from the eco-roofs was about half that from hard roofs and was close to that of small natural rivers. However, although most rainy days there was no or little runoff from the roofs, the highest observed daily runoff values were close to the daily rainfall. Runoff is initiated, when the soil is at field capacity. Thereafter the hourly runoff corresponds closely to the hourly rainfall. For short-term high intensity storms, the runoff peak is attenuated relative the rain intensity. The time of concentration for runoff was experimentally determined applying artificial rains on existing roofs and on experimental roof plots with varying slopes and using different drainage layers. The peak runoff from the roofs was found to correspond to the rain intensity over 20-30 minutes. The probability of high rain intensity is much higher than the probability of high runoff. When intensity-duration-frequency curves were constructed, runoff with 0.4 year return period corresponded to rain with 1.5 year return period. The influence of the slope of the roofs on the runoff peak was minor as was the effect of drainage layer. The vertical flow in the soil dominates the runoff process. The influence of extensive sedum-moss vegetated roofs on runoff quality was also studied to ascertain whether vegetated roofs behave as sink or source of pollutants and whether the runoff quality changes

  11. 75 FR 34170 - Plastic Omnium Automotive Exteriors, LLC, Anderson, SC; Plastic Omnium Automotive Exteriors, LLC...

    Science.gov (United States)

    2010-06-16

    ... Employment and Training Administration Plastic Omnium Automotive Exteriors, LLC, Anderson, SC; Plastic Omnium... Assistance on March 18, 2010, applicable to workers of Plastic Omnium Automotive Exteriors, LLC, Anderson... have occurred involving workers in support of the Anderson, South Carolina location of Plastic...

  12. PREDICTING THERMAL PERFORMANCE OF ROOFING SYSTEMS IN SURABAYA

    OpenAIRE

    2015-01-01

    Traditional roofing systems in the developing country likes Indonesia are still be dominated by the 30o, 45o, and more pitched angle roofs; the roofing cover materials are widely used to traditional clay roof tiles, then modern concrete roof tiles, and ceramic roof tiles. In the 90’s decay, shop houses are prosperous built with flat concrete roofs dominant. Green roofs and roof ponds are almost rarely built to meet the sustainable environmental issues. Some tested various roof systems in Sura...

  13. Generating realistic roofs over a rectilinear polygon

    KAUST Repository

    Ahn, Heekap

    2011-01-01

    Given a simple rectilinear polygon P in the xy-plane, a roof over P is a terrain over P whose faces are supported by planes through edges of P that make a dihedral angle π/4 with the xy-plane. In this paper, we introduce realistic roofs by imposing a few additional constraints. We investigate the geometric and combinatorial properties of realistic roofs, and show a connection with the straight skeleton of P. We show that the maximum possible number of distinct realistic roofs over P is ( ⌊(n-4)/4⌋ (n-4)/2) when P has n vertices. We present an algorithm that enumerates a combinatorial representation of each such roof in O(1) time per roof without repetition, after O(n 4) preprocessing time. We also present an O(n 5)-time algorithm for computing a realistic roof with minimum height or volume. © 2011 Springer-Verlag.

  14. Ontkenning vaderschap door bijzondere curator namens minderjarige

    NARCIS (Netherlands)

    A.J.M. Nuytinck (André)

    2004-01-01

    textabstractOntkenning vaderschap door minderjarig kind, vertegenwoordigd door een daartoe benoemde bijzondere curator; niet vereist dat kind in staat is tot redelijke waardering belangen; belang van zeer jeugdig kind kan anders meebrengen

  15. Ontkenning vaderschap door bijzondere curator namens minderjarige

    NARCIS (Netherlands)

    A.J.M. Nuytinck (André)

    2004-01-01

    textabstractOntkenning vaderschap door minderjarig kind, vertegenwoordigd door een daartoe benoemde bijzondere curator; niet vereist dat kind in staat is tot redelijke waardering belangen; belang van zeer jeugdig kind kan anders meebrengen

  16. Smediger kaas door juiste voer

    NARCIS (Netherlands)

    Hettinga, K.A.; Dijkstra, J.

    2014-01-01

    Veel kaasmakers willen smedige (zachte, smeuïge) kaas maken, want de gemiddelde consument vindt die kaas het lekkerst. Kasper Hettinga en Jan Dijkstra van Wageningen Universiteit vertellen hoe de smedigheid van kaas kan worden beïnvloed door de samenstelling van het veevoer.

  17. Project Open Door. Final Report.

    Science.gov (United States)

    Verheyden-Hilliard, Mary Ellen

    The major purpose of Project Open Door was to design, develop, test, and disseminate a portable module for vocational educators and others to use with junior high school students in pre-vocational exploration free of sex stereotyping. The module produced contained a slide presentation with accompanying cassette tape and a leader's guide. An…

  18. Koperemissies door drinkwaterleidingen (herziene editie)

    NARCIS (Netherlands)

    Verweij W; Mons MN; Aalbers JEM; Cruchten RGH van; LWD

    1996-01-01

    Ge-inventariseerd werd wat er bekend is over de fluxen van koper door (corrosie van) waterleidingen naar rioolwaterzuiveringsinstallaties (rwzi's), rwzi-slib en het oppervlaktewater. Gebleken is dat in 1993 (landelijk gemiddeld) 57% van de koperbelasting van rwzi's afkomstig is van cor

  19. Construction Guidelines for High R-Value Walls without Exterior Rigid Insulation

    Energy Technology Data Exchange (ETDEWEB)

    Arena, Lois B. [Steven Winter Associates, Inc., Norwalk, CT (United States). Consortium for Advanced Residential Buildings

    2016-07-13

    High-R wall assemblies (R-40 and above) are gaining popularity in the market due to programs like the DOE's Zero Energy Ready Home program, Passive House (PH), Net Zero Energy Home (NZEH) challenges in several states, and highly incentivized retrofit programs. In response to this demand, several builders have successfully used 'double wall' systems to more practically achieve higher R-values in thicker, framed walls. To builders of conventional stick-framed homes, often one of the most appealing features of double wall systems is that there are very few new exterior details. Exterior sheathing, structural bracing, house wrap or building paper, window and door flashing, and siding attachment are usually identical to good details in conventional framed wall systems. The information presented in this guide is intended to reduce the risk of failure in these types of assemblies, increase durability, and result in a reduction of material brought to landfills due to failures and resulting decay. While this document focuses on double wall framing techniques, the majority of the information on how to properly construct and finish high R-value assemblies is applicable to all wall assemblies that do not have foam insulation installed on the exterior of the structural sheathing. The techniques presented have been shown through field studies to reduce the likelihood of mold growth and moisture related damage and are intended for builders, framing contractors, architects, and consultants involved in designing and building super insulated homes.

  20. Development of a Long-Life-Cycle, Highly Water-Resistant Solar Reflective Retrofit Roof Coating

    Energy Technology Data Exchange (ETDEWEB)

    Polyzos, Georgios [ORNL; Hunter, Scott Robert [ORNL; Sharma, Jaswinder K [ORNL; Cheng, Mengdawn [ORNL; Chen, Sharon S [Lawrence Berkeley National Laboratory (LBNL); Demarest, Victoria [Dow Chemical Company; Fabiny, William [Dow Chemical Company; Destaillats, Hugo [Lawrence Berkeley National Laboratory (LBNL); Levinson, Ronnen [Lawrence Berkeley National Laboratory (LBNL)

    2016-03-04

    Highly water-resistant and solar-reflective coatings for low-slope roofs are potentially among the most economical retrofit approaches to thermal management of the building envelope. Therefore, they represent a key building technology research program within the Department of Energy. Research efforts in industry and the Department of Energy are currently under way to increase long-term solar reflectance on a number of fronts. These include new polymer coatings technologies to provide longer-lasting solar reflectivity and improved test methodologies to predict long-term soiling and microbial performance. The focus on long-term improvements in soiling and microbial resistance for maximum reflectance does not address the single most important factor impacting the long-term sustainability of low-slope roof coatings: excellent water resistance. The hydrophobic character of asphaltic roof products makes them uniquely suitable for water resistance, but their low albedo and poor exterior durability are disadvantages. A reflective coating that maintains very high water resistance with increased long-term resistance to soiling and microbial activity would provide additional energy savings and extend roof service life.

  1. Evaluating convex roof entanglement measures.

    Science.gov (United States)

    Tóth, Géza; Moroder, Tobias; Gühne, Otfried

    2015-04-24

    We show a powerful method to compute entanglement measures based on convex roof constructions. In particular, our method is applicable to measures that, for pure states, can be written as low order polynomials of operator expectation values. We show how to compute the linear entropy of entanglement, the linear entanglement of assistance, and a bound on the dimension of the entanglement for bipartite systems. We discuss how to obtain the convex roof of the three-tangle for three-qubit states. We also show how to calculate the linear entropy of entanglement and the quantum Fisher information based on partial information or device independent information. We demonstrate the usefulness of our method by concrete examples.

  2. Factors Influencing Arthropod Diversity on Green Roofs

    Directory of Open Access Journals (Sweden)

    Bracha Y. Schindler

    2011-01-01

    Full Text Available Green roofs have potential for providing substantial habitat to plants, birds, and arthropod species that are not well supported by other urban habitats. Whereas the plants on a typical green roof are chosen and planted by people, the arthropods that colonize it can serve as an indicator of the ability of this novel habitat to support a diverse community of organisms. The goal of this observational study was to determine which physical characteristics of a roof or characteristics of its vegetation correlate with arthropod diversity on the roof. We intensively sampled the number of insect families on one roof with pitfall traps and also measured the soil arthropod species richness on six green roofs in the Boston, MA area. We found that the number of arthropod species in soil, and arthropod families in pitfall traps, was positively correlated with living vegetation cover. The number of arthropod species was not significantly correlated with plant diversity, green roof size, distance from the ground, or distance to the nearest vegetated habitat from the roof. Our results suggest that vegetation cover may be more important than vegetation diversity for roof arthropod diversity, at least for the first few years after establishment. Additionally, we found that even green roofs that are small and isolated can support a community of arthropods that include important functional groups of the soil food web.

  3. Demonstration of energy savings of cool roofs

    Energy Technology Data Exchange (ETDEWEB)

    Konopacki, S.; Gartland, L.; Akbari, H. [Lawrence Berkeley National Lab., CA (United States). Environmental Energy Technologies Div.; Rainer, L. [Davis Energy Group, Davis, CA (United States)

    1998-06-01

    Dark roofs raise the summertime air-conditioning demand of buildings. For highly-absorptive roofs, the difference between the surface and ambient air temperatures can be as high as 90 F, while for highly-reflective roofs with similar insulative properties, the difference is only about 20 F. For this reason, cool roofs are effective in reducing cooling energy use. Several experiments on individual residential buildings in California and Florida show that coating roofs white reduces summertime average daily air-conditioning electricity use from 2--63%. This demonstration project was carried out to address some of the practical issues regarding the implementation of reflective roofs in a few commercial buildings. The authors monitored air-conditioning electricity use, roof surface temperature, plenum, indoor, and outdoor air temperatures, and other environmental variables in three buildings in California: two medical office buildings in Gilroy and Davis and a retail store in San Jose. Coating the roofs of these buildings with a reflective coating increased the roof albedo from an average of 0.20--0.60. The roof surface temperature on hot sunny summer afternoons fell from 175 F--120 F after the coating was applied. Summertime average daily air-conditioning electricity use was reduced by 18% (6.3 kWh/1000ft{sup 2}) in the Davis building, 13% (3.6 kWh/1000ft{sup 2}) in the Gilroy building, and 2% (0.4 kWh/1000ft{sup 2}) in the San Jose store. In each building, a kiosk was installed to display information from the project in order to educate and inform the general public about the environmental and energy-saving benefits of cool roofs. They were designed to explain cool-roof coating theory and to display real-time measurements of weather conditions, roof surface temperature, and air-conditioning electricity use. 55 figs., 15 tabs.

  4. Future oriented and more sustainable green roofs

    Energy Technology Data Exchange (ETDEWEB)

    Appl, R.; Ansel, W. [Deutscher Dachgartnerverband, Nuertingen (Germany)

    2004-07-01

    The contribution that green roofs make to sustainable urban Development were discussed with reference to the support that the industry has received in Germany. The German Roof Gardener Association (DDV) was established in the 1990s with an objective to replace the billions of square feet of bare or gravel flat roof surface area in Germany with ecological green roofs. The DDV created guidelines for the systems and components being used in green roof constructions, starting from the raw material to the production and transport of the material, and to the recycling of the material after demolition. Green roofs in Germany are now made mandatory by local authorities. Green roofs offer innovative technological features as well as additional use. Combined with extensive or intensive greening, these roofs reduce the use of building land. They must be built to last the lifetime of the building and given proper care and maintenance. In the twenty-first century, green roof systems will be made of recycled and environmentally sound material. The purpose of the green roof is to provide not only a permanent location for vegetation, but also offer further possibilities of utilization, such as additional thermal insulation, fall protection systems or even constructions for solar power facilities. This paper addressed issues regarding the extended life expectancy of a roof, savings on stormwater tax and thermal values for insulation calculations. Green roofs in Germany currently represent an important element in stormwater management by slowing down, filtering and diminishing rain water runoff. The excess water is guided into cisterns and used for the irrigation of the roof gardens and for flushing toilets. 5 figs.

  5. Demonstration of energy savings of cool roofs

    Energy Technology Data Exchange (ETDEWEB)

    Konopacki, S.; Gartland, L.; Akbari, H. [Lawrence Berkeley National Lab., CA (United States). Environmental Energy Technologies Div.; Rainer, L. [Davis Energy Group, Davis, CA (United States)

    1998-06-01

    Dark roofs raise the summertime air-conditioning demand of buildings. For highly-absorptive roofs, the difference between the surface and ambient air temperatures can be as high as 90 F, while for highly-reflective roofs with similar insulative properties, the difference is only about 20 F. For this reason, cool roofs are effective in reducing cooling energy use. Several experiments on individual residential buildings in California and Florida show that coating roofs white reduces summertime average daily air-conditioning electricity use from 2--63%. This demonstration project was carried out to address some of the practical issues regarding the implementation of reflective roofs in a few commercial buildings. The authors monitored air-conditioning electricity use, roof surface temperature, plenum, indoor, and outdoor air temperatures, and other environmental variables in three buildings in California: two medical office buildings in Gilroy and Davis and a retail store in San Jose. Coating the roofs of these buildings with a reflective coating increased the roof albedo from an average of 0.20--0.60. The roof surface temperature on hot sunny summer afternoons fell from 175 F--120 F after the coating was applied. Summertime average daily air-conditioning electricity use was reduced by 18% (6.3 kWh/1000ft{sup 2}) in the Davis building, 13% (3.6 kWh/1000ft{sup 2}) in the Gilroy building, and 2% (0.4 kWh/1000ft{sup 2}) in the San Jose store. In each building, a kiosk was installed to display information from the project in order to educate and inform the general public about the environmental and energy-saving benefits of cool roofs. They were designed to explain cool-roof coating theory and to display real-time measurements of weather conditions, roof surface temperature, and air-conditioning electricity use. 55 figs., 15 tabs.

  6. Roof Polishing of Optical Fibers

    Science.gov (United States)

    Dholakia, A. R.

    1985-01-01

    Bevealed tip gives optimum coupling efficiency. Abrasive tape used to grind tip of optical fiber. Grinding force depends on stiffness of optical fiber. "Roof" shape on end of optical glass fiber increases efficiency which couples laser light. End surface angle of 65 degrees with perpendicular required for optimum coupling. Since fiber and tape are light in weight and compliant, ridge defect-free, and chipping on fiber edge totally eliminated.

  7. Solar thermal roofs; Zonthermische daken

    Energy Technology Data Exchange (ETDEWEB)

    Van de Waerdt, J. [DWA installatie- en energieadvies, Bodegraven (Netherlands)

    2012-11-15

    The purpose of the brochure is to increase the effective application of solar thermal roofs. The target group includes consultants, installers, architects and contractors. Attention is paid to the design, parameters for comparison, yield simulations and experiences gained in projects [Dutch] Het doel van de brochure is het vergroten van de effectieve toepassing van zonthermische daken. Tot de doelgroep behoren installatieadviseurs, installateurs, architecten en opdrachtgevers in de bouw. Aandacht wordt besteed aan het ontwerp, parameters voor vergelijking, opbrengstsimulaties en ervaringen opgedaan in projecten.

  8. Polyurethane adhesives in flat roofs

    Directory of Open Access Journals (Sweden)

    Bogárová Markéta

    2017-01-01

    Full Text Available It is necessary to stabilize individual layers of flat roofs, mainly because of wind suction. Apart from anchoring and surcharge, these layers can be secured by bonding. At present gluing is an indispensable and widely used stabilization method. On our market we can found many types of adhesives, most widely used are based on polyurethane. This paper focuses on problematic about stabilization thermal insulation from expanded polystyrene to vapor barrier from bitumen. One of the main issues is to calculate the exact amount of adhesive, which is required to guarantee the resistance against wind suction. In this problematic we can not find help neither in technical data sheets provided by the manufactures. Some of these data sheets contain at least information about amount of adhesive depending on location in roof plane and building height, but they do not specify the strength of such connection. It was therefore resorted to select several representatives polyurethane adhesives and their subsequent testing on specimens simulating the flat roof segment. The paper described the test methodology and results for two types of polyurethane adhesives.

  9. A Door-to-Door Combined Transport Planner

    DEFF Research Database (Denmark)

    Aastrup, Jesper; Jespersen, Per Homann; Pedersen, Michael B.

    2004-01-01

    - and inter-organizational barriers to the establishment of a competitive and effective combined transport system with rail freight operators as the intermodal integrator. In this paper we describes the ideas and methodology behind the project, as well as some preliminary results.......Establishing a web-based portal functioning as a one-stop-shop for transport buyers is a radical idea of a consumer oriented intermodal freight system. This utopian vision will be materialized in a system description and a prototype of a Door-to-Door Combined Trans-port Planner (COTRAP), developed...... to fulfill the requirements of potential customers and in interaction with customers, shippers, rail and road freight operators, rail infrastructure owners and other actors in the intermodal freight system. Conversely, successive versions of the COTRAP will be used as an instrument to identify intra...

  10. Relevance of exterior appraisal in pig breeding.

    NARCIS (Netherlands)

    Steenbergen, van E.J.

    1990-01-01

    In farm animals characterization of exterior is not a goal in itself but rather serves as an indicator of economically important traits, i.e. for pigs: growth performance, reproductivity and constitution. This indication might be of interest when these traits can not be measured on living animal

  11. Relevance of exterior appraisal in pig breeding

    NARCIS (Netherlands)

    Steenbergen, van E.J.

    1990-01-01

    In farm animals characterization of exterior is not a goal in itself but rather serves as an indicator of economically important traits, i.e. for pigs: growth performance, reproductivity and constitution. This indication might be of interest when these traits can not be measured o

  12. Nonstatic vacuum strings: Exterior and interior solutions

    Energy Technology Data Exchange (ETDEWEB)

    Stein-Schabes, J.A.

    1986-06-15

    New nonstatic cylindrically symmetric solutions of Einstein's equations are presented. Some of these solutions represent stringlike objects. An exterior vacuum solution is matched to a nonvacuum interior solution for different forms of the energy-momentum tensor. They generalize the standard static string.

  13. TASK 2.5.7 FIELD EXPERIMENTS TO EVALUATE COOL-COLORED ROOFING

    Energy Technology Data Exchange (ETDEWEB)

    Miller, William A [ORNL; Cherry, Nigel J [ORNL; Allen, Richard Lowell [ORNL; Childs, Phillip W [ORNL; Atchley, Jerald Allen [ORNL; Ronnen, Levinson [Lawrence Berkeley National Laboratory (LBNL); Akbari, Hashem [Lawrence Berkeley National Laboratory (LBNL); Berhahl, Paul [Lawrence Berkeley National Laboratory (LBNL)

    2010-03-01

    Aesthetically pleasing dark roofs can be formulated to reflect like a highly reflective white roof in the near infrared portion of the solar spectrum. New paint pigments increase the near infrared reflectance of exterior finishes by minimizing the absorption of near-infrared radiation (NIR). The boost in the NIR reflectance drops the surface temperatures of roofs and walls, which in turn reduces cooling-energy use and provides savings for the homeowner and relief for the utilities. In moderate and hot climates, a roof surface with high solar reflectance and high thermal emittance was shown by Akbari et al. (2004) and by Parker and Sherwin (1998) to reduce the exterior temperature and produce savings in comfort cooling. The new cool color pigments can potentially reduce emissions of carbon dioxide, which in turn reduces metropolitan heat buildup and urban smog. The pigments can also help conserve water resources otherwise used to clean and process fuel consumed by fossil-fuel driven power plants. Cool roofs also result in a lower ambient temperature that further decreases the need for air conditioning, retards smog formation, and improves thermal comfort. Parker, Sonne and Sherwin (2002) demonstrated that white barrel and white flat tiles reduced cooling energy consumption by 22% of the base load used by an adjacent and identical home having direct nailed dark shingles. Part of the savings was due to the reflectance of the white tiles; however, another part was due to the mass of the tile and to the venting occurring within the double batten installation. With, Cherry and Haig (2009) have studied the influence of the thermal mass and batten space ventilation and have found that, referenced to an asphalt shingle system, it can be equivalent to an additional 28 points of solar reflectivity. The double batten arrangement has wooden counter battens laid vertically (soffit-to-ridge) against the roof deck, and then the conventional battens are laid horizontally across the

  14. Extensive Green Roof Ecological Benefits in Latvia

    OpenAIRE

    Rušenieks, Rihards; Kamenders, Agris

    2013-01-01

    Extensive green roof ecological benefits are studiedin this paper. The research contains a brief explanation aboutgreen roof technology and green roof ecological benefits. Greenroof capability to retain rainwater runoff by accumulating it instorage layers and conducting it back into the atmospherethrough evapotranspiration is studied and modeled. Modeling isdone in Stormwater Management Model 5.0 software. The modelis based on an existing warehouse-type building located in Rigaand hourly Riga...

  15. Realistic roofs over a rectilinear polygon

    KAUST Repository

    Ahn, Heekap

    2013-11-01

    Given a simple rectilinear polygon P in the xy-plane, a roof over P is a terrain over P whose faces are supported by planes through edges of P that make a dihedral angle π/4 with the xy-plane. According to this definition, some roofs may have faces isolated from the boundary of P or even local minima, which are undesirable for several practical reasons. In this paper, we introduce realistic roofs by imposing a few additional constraints. We investigate the geometric and combinatorial properties of realistic roofs and show that the straight skeleton induces a realistic roof with maximum height and volume. We also show that the maximum possible number of distinct realistic roofs over P is ((n-4)(n-4)/4 /2⌋) when P has n vertices. We present an algorithm that enumerates a combinatorial representation of each such roof in O(1) time per roof without repetition, after O(n4) preprocessing time. We also present an O(n5)-time algorithm for computing a realistic roof with minimum height or volume. © 2013 Elsevier B.V.

  16. Green roofs provide habitat for urban bats

    Directory of Open Access Journals (Sweden)

    K.L. Parkins

    2015-07-01

    Full Text Available Understanding bat use of human-altered habitat is critical for developing effective conservation plans for this ecologically important taxon. Green roofs, building rooftops covered in growing medium and vegetation, are increasingly important conservation tools that make use of underutilized space to provide breeding and foraging grounds for urban wildlife. Green roofs are especially important in highly urbanized areas such as New York City (NYC, which has more rooftops (34% than green space (13%. To date, no studies have examined the extent to which North American bats utilize urban green roofs. To investigate the role of green roofs in supporting urban bats, we monitored bat activity using ultrasonic recorders on four green and four conventional roofs located in highly developed areas of NYC, which were paired to control for location, height, and local variability in surrounding habitat and species diversity. We then identified bat vocalizations on these recordings to the species level. We documented the presence of five of nine possible bat species over both roof types: Lasiurus borealis, L. cinereus, L. noctivagans, P. subflavus,andE. fuscus. Of the bat calls that could be identified to the species level, 66% were from L. borealis. Overall levels of bat activity were higher over green roofs than over conventional roofs. This study provides evidence that, in addition to well documented ecosystem benefits, urban green roofs contribute to urban habitat availability for several North American bat species.

  17. Orbital dystopia due to orbital roof defect.

    Science.gov (United States)

    Rha, Eun Young; Joo, Hong Sil; Byeon, Jun Hee

    2013-01-01

    We performed a retrospective review of patients who presented with delayed dystopia as a consequence of an orbital roof defect due to fractures and nontraumatic causes to search for a correlation between orbital roof defect size and surgical indications for the treatment thereof. Retrospective analyses were performed in 7 patients, all of whom presented with delayed dystopia due to orbital roof defects, between January 2001 and June 2011. The causes of orbital roof defects were displaced orbital roof fractures (5 cases), tumor (1 case), and congenital sphenoid dysplasia (1 case). All 7 patients had initially been treated conservatively and later presented with significant dystopia. The sizes of the defects were calculated on computed tomographic scans. Among the 7 patients, aspiration of cerebrospinal fluid, which caused ocular symptoms, in 1 patient with minimal displaced orbital roof and reconstruction with calvarial bone, titanium micromesh, or Medpor in 6 other patients were performed. The minimal size of the orbital roof in patients who underwent orbital roof reconstruction was 1.2 cm (defect height) x 1.0 cm (defect length), 0.94 cm(2). For all patients with orbital dystopia, displacement of the globe was corrected without any complications, regardless of whether the patient was evaluated grossly or by radiology. In this retrospective study, continuous monitoring of clinical signs and active surgical management should be considered for cases in which an orbital roof defect is detected, even if no definite symptoms are noted, to prevent delayed sequelae.

  18. On realizations of exterior calculus with dN = 0

    Science.gov (United States)

    Abramov, V.

    1998-11-01

    We study realizations of the q-exterior calculus with exterior differential d satisfying d N = 0, N > 2 on the free associative algebra with one generator and on the generalized Clifford algebras. Analogs of the notions of connection and curvature are discussed in the case of the q-exterior calculus on the generalized Clifford algebra. We show that the q-exterior calculus on the free associative algebra with one generator is related to q-calculus on the braided line.

  19. Experimental analysis of single sided ventilation through a centre pivot roof window

    DEFF Research Database (Denmark)

    Iqbal, Ahsan; Afshari, Alireza; Heiselberg, Per

    2015-01-01

    In the present study bidirectional airflow characteristics of a centre-pivot roof window were analysed in-situ. Both wind and temperature differences were present at the time of measurements. Tracer gas technique using N2O gas was used to estimate the air change rates in the experimental space....... Leakages through the experimental space were estimated using the blower door tests. Air-change rates increased with increase in the window sash opening angle. When the window was open all the way, with an average wind speed of 4 m/s, the average air-change rate was 2. Flow factor was used to characterise...

  20. A NONOVERLAPPING DOMAIN DECOMPOSITION METHOD FOR EXTERIOR 3-D PROBLEM

    Institute of Scientific and Technical Information of China (English)

    De-hao Yu; Ji-ming Wu; Ji-ming Wu

    2001-01-01

    In this paper, a nonoverlapping domain decomposition method, which is based on the natural boundary reduction(cf. [4, 13, 15]), is developed to solve the boundary value problem in exterior three-dimensional domain of general shape. Convergence analyses both for the exterior spherical domain and the general exterior domain are made. Some numerical examples are also provided to illustrate the method.

  1. Final Environmental Assessment: Construction of Maintenance and Storage Facility, Perimeter Fence Upgrade and Demolition of Three Buildings and Two Structures Gila River Air Force Space Surveillance Station Arizona

    Science.gov (United States)

    2012-11-01

    a 15 foot long driveway, exterior doors, windows, six-inch insulation for the wall and roof, three overhead roll-up doors (12’ high x 12‘ wide...a wood screen on two sides. Five steel pipe columns support a steel-framed, shallow-pitched shed roof with corrugated steel-panel roofing...ACM—packings, gaskets, resilient floor covering, pliable sealants and mastics and asphalt roofing products containing more than one percent asbestos

  2. Wind loads on solar energy roofs

    NARCIS (Netherlands)

    Geurts, C.P.W.; Bentum, C.A. van

    2007-01-01

    This paper presents an overview of the wind loads on roofs, equipped with solar energy products, so called Active Roofs. Values given in this paper have been based on wind tunnel and full scale measurements, carried out at TNO, and on an interpretation of existing rules and guidelines. The results a

  3. Integrated roof wind energy system

    Directory of Open Access Journals (Sweden)

    Moonen S.P.G.

    2012-10-01

    Full Text Available Wind is an attractive renewable source of energy. Recent innovations in research and design have reduced to a few alternatives with limited impact on residential construction. Cost effective solutions have been found at larger scale, but storage and delivery of energy to the actual location it is used, remain a critical issue. The Integrated Roof Wind Energy System is designed to overcome the current issues of urban and larger scale renewable energy system. The system is built up by an axial array of skewed shaped funnels that make use of the Venturi Effect to accelerate the wind flow. This inventive use of shape and geometry leads to a converging air capturing inlet to create high wind mass flow and velocity toward a vertical-axis wind turbine in the top of the roof for generation of a relatively high amount of energy. The methods used in this overview of studies include an array of tools from analytical modelling, PIV wind tunnel testing, and CFD simulation studies. The results define the main design parameters for an efficient system, and show the potential for the generation of high amounts of renewable energy with a novel and effective system suited for the built environment.

  4. Integrated roof wind energy system

    Science.gov (United States)

    Suma, A. B.; Ferraro, R. M.; Dano, B.; Moonen, S. P. G.

    2012-10-01

    Wind is an attractive renewable source of energy. Recent innovations in research and design have reduced to a few alternatives with limited impact on residential construction. Cost effective solutions have been found at larger scale, but storage and delivery of energy to the actual location it is used, remain a critical issue. The Integrated Roof Wind Energy System is designed to overcome the current issues of urban and larger scale renewable energy system. The system is built up by an axial array of skewed shaped funnels that make use of the Venturi Effect to accelerate the wind flow. This inventive use of shape and geometry leads to a converging air capturing inlet to create high wind mass flow and velocity toward a vertical-axis wind turbine in the top of the roof for generation of a relatively high amount of energy. The methods used in this overview of studies include an array of tools from analytical modelling, PIV wind tunnel testing, and CFD simulation studies. The results define the main design parameters for an efficient system, and show the potential for the generation of high amounts of renewable energy with a novel and effective system suited for the built environment.

  5. Excavationless Exterior Foundation Insulation Exploratory Study

    Energy Technology Data Exchange (ETDEWEB)

    Mosiman, G.; Wagner, R.; Schirber, T.

    2013-02-01

    The key objective of this exploratory study was to investigate the feasibility of the development or adoption of technologies that would enable a large percentage of existing homes in cold climates to apply a combination 'excavationless' soil removal process with appropriate insulation and water management on the exterior of existing foundations at a low cost. Our approach was to explore existing excavation and material technologies and systems to discover whether potential successful combinations existed.

  6. Excavationless Exterior Foundation Insulation Exploratory Study

    Energy Technology Data Exchange (ETDEWEB)

    Mosimann, Garrett [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR Building America Partnership; Wagner, Rachel [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR Building America Partnership; Schirber, Tom [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR Building America Partnership

    2013-02-01

    The key objective of this exploratory study was to investigate the feasibility of the development or adoption of technologies that would enable a large percentage of existing homes in cold climates to apply a combination 'excavationless' soil removal process with appropriate insulation and water management on the exterior of existing foundations at a low cost. Our approach was to explore existing excavation and material technologies and systems to discover whether potential successful combinations existed.

  7. Exterior LED Lighting Projects at Princeton University

    Energy Technology Data Exchange (ETDEWEB)

    Davis, Robert G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Evans, William [Princeton Univ., NJ (United States); Murphy, Arthur T. [Princeton Univ., NJ (United States); Perrin, Tess E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-10-01

    For this report, PNNL / the U.S. Department of Energy (DOE) studied a series of past exterior lighting projects at Princeton, in order to document Princeton’s experiences with solid-state lighting (SSL) and the lessons learned along the way, and to show how their approach to SSL projects evolved as their own learning expanded and as the products available improved in performance and sophistication.

  8. Exterior exposed ductwork: Delivery effectiveness and efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Delp, W.W.; Matson, N.; Modera, M.P.

    1996-07-01

    Most of California`s light commercial buildings use air transport through ductwork for thermal distribution. The same air distribution systems are often used to provide both thermal comfort and ventilation. Some air distribution ductwork is installed on rooftops, exposed directly to the outside environment. As such, there exist potential energy penalties related to externally installed ductwork. In order to evaluate the magnitude of these penalties, a case study was conducted of a one-story community college building, located in California`s Sacramento Valley. The majority of the building`s air distribution ductwork was located on the roof. Energy-related issues studied in this case included duct-related thermal losses (duct leakage and conduction), delivery effectiveness and efficiency, thermal comfort issues and the effect of a roof retrofit (additional insulation and a reflective coating). The building in this study underwent a retrofit project involving additional insulation and a highly reflective coating applied to the roof and ducts. As part of this project, methods were developed to analyze the air distribution system effectiveness independent of the introduction of outside air through an outside air damper. A simplified model was developed to predict the effectiveness and efficiency of the distribution system. The time frame of the retrofit allowed two separate three week monitoring periods. Despite the fact that the ducts started off with a conduction efficiency of 97%, the delivery efficiency was on average only 73% (with a supply side effectiveness of 78% and return effectiveness of 92%). This is due to the losses from the ducts being located on the roof. The retrofit increased the delivery efficiency to an average of 89% (with a supply side effectiveness of 90% and return effectiveness of 99%), reducing the average energy use for conditioning by 22%. The model predicted, on average, the results within 10%, or better, of measured results.

  9. Thermal insulation performance of green roof systems

    Energy Technology Data Exchange (ETDEWEB)

    Celik, Serdar; Morgan, Susan; Retzlaff, William; Once, Orcun [southern Illinois University (United States)], e-mail: scelik@siue.edu, e-mail: smorgan@siue.edu, e-mail: wretzla@siue.edu, e-mail: oonce@siue.edu

    2011-07-01

    With the increasing costs of energy, good building insulation has become increasingly important. Among existing insulation techniques is the green roof system, which consists of covering the roof of a building envelop with plants. The aim of this paper is to assess the impact of vegetation type and growth media on the thermal performance of green roof systems. Twelve different green roof samples were made with 4 different growth media and 3 sedum types. Temperature at the sample base was recorded every 15 minutes for 3 years; the insulation behavior was then analysed. Results showed that the insulation characteristics were achieved with a combination of haydite and sedum sexangulare. This study demonstrated that the choice of growth media and vegetation is important to the green roof system's performance; further research is required to better understand the interactions between growth media and plant roots.

  10. Experimental polyurethane foam roof systems, part 2

    Science.gov (United States)

    Alumbaugh, R. L.; Keeton, J. R.; Humm, E. F.

    1983-01-01

    An experimental roofing installation is described in which polyurethane foam (PUF) was spray-applied directly to metal Butlerib-type metal decks, the roof divided into five approximately equal areas, and the PUF protected with five different elastomeric coating systems. Three of the coating systems were damaged by hailstones about a year after installation; these systems were recoated within 3 years of the initial installation. The current coatings include two of the original coating systems - a plural component silicone and a single component silicone - and those applied over the three systems damaged by hail - a single component silicone, an aluminum filled, hydrocarbon-extended catalyzed urethane, and a catalyzed urethane. The performance of these five PUF systems over a 7-year period is reported. The temperature distributions throughout the roof systems are described. The decay in the thermal conductivity of the PUF roof over a 5-year period is presented, and the energy savings realized by foaming the roof are presented.

  11. Excavationless Exterior Foundation Insulation Field Study

    Energy Technology Data Exchange (ETDEWEB)

    Schirber, T. [NorthernSTAR, Minneaplolis, MN (United States); Mosiman, G. [NorthernSTAR, Minneaplolis, MN (United States); Ojczyk, C. [NorthernSTAR, Minneaplolis, MN (United States)

    2014-09-01

    Building science research supports installing exterior (soil side) foundation insulation as the optimal method to enhance the hygrothermal performance of new homes. With exterior foundation insulation, water management strategies are maximized while insulating the basement space and ensuring a more even temperature at the foundation wall. However, such an approach can be very costly and disruptive when applied to an existing home, requiring deep excavation around the entire house. The NorthernSTAR Building America Partnership team implemented an innovative, minimally invasive foundation insulation upgrade technique on an existing home. The approach consisted of using hydrovac excavation technology combined with liquid insulating foam. The team was able to excavate a continuous 4 inches wide by 4 feet to 5 feet deep trench around the entire house, 128 linear feet, except for one small part under the stoop that was obstructed with concrete debris. The combination pressure washer and vacuum extraction technology also enabled the elimination of large trenches and soil stockpiles normally produced by backhoe excavation. The resulting trench was filled with liquid insulating foam, which also served as a water-control layer of the assembly. The insulation was brought above grade using a liquid foam/rigid foam hybrid system and terminated at the top of the rim joist. Cost savings over the traditional excavation process ranged from 23% to 50%. The excavationless process could result in even greater savings since replacement of building structures, exterior features, utility meters, and landscaping would be minimal or non-existent in an excavationless process.

  12. Excavationless Exterior Foundation Insulation Field Study

    Energy Technology Data Exchange (ETDEWEB)

    Schirber, T.; Mosiman, G.; Ojczyk, C.

    2014-10-01

    Building science research supports installing exterior (soil side) foundation insulation as the optimal method to enhance the hygrothermal performance of new homes. With exterior foundation insulation, water management strategies are maximized while insulating the basement space and ensuring a more even temperature at the foundation wall. However, such an approach can be very costly and disruptive when applied to an existing home, requiring deep excavation around the entire house. The NorthernSTAR Building America Partnership team implemented an innovative, minimally invasive foundation insulation upgrade technique on an existing home. The approach consisted of using hydrovac excavation technology combined with a liquid insulating foam. The team was able to excavate a continuous 4" wide by 4' to 5' deep trench around the entire house, 128 linear feet, except for one small part under the stoop that was obstructed with concrete debris. The combination pressure washer and vacuum extraction technology also enabled the elimination of large trenches and soil stockpiles normally produced by backhoe excavation. The resulting trench was filled with liquid insulating foam, which also served as a water-control layer of the assembly. The insulation was brought above grade using a liquid foam/rigid foam hybrid system and terminated at the top of the rim joist. Cost savings over the traditional excavation process ranged from 23% to 50%. The excavationless process could result in even greater savings since replacement of building structures, exterior features, utility meters, and landscaping would be minimal or non-existent in an excavationless process.

  13. Holiday Door Decorating Contest Brings Cheer | Poster

    Science.gov (United States)

    By Carolynne Keenan, Contributing Writer Other than the time of year, what do the following have in common: the leg lamp from the movie “A Christmas Story,” a compilation of silly holiday jokes, a gingerbread house, and Santa on a motorcycle? All four were among the individual door winners for the Holiday Door Decorating Contest, held at NCI at Frederick in December. Employees dressed up their office doors, hallways, and even stairwells to participate. Entries for the contest included individual office doors as well as groups. Some employees even “decked the halls” of whole office buildings to participate.

  14. Literature Survey on Door Lock Security Systems

    National Research Council Canada - National Science Library

    Pradnya R Nehete; J P Chaudhari; S R Pachpande; K P Rane

    2016-01-01

    .... Due to the advancement in recent techniques, some door lock security systems are based on microcontroller, GSM, GPS, many sensors, software like MATLAB, PROTEUS, biometrics like face recognition...

  15. Roof Rockmass Characterization in an Illinois Underground Coal Mine

    Science.gov (United States)

    Osouli, Abdolreza; Shafii, Iman

    2016-08-01

    Among all United States underground coal fields, those in Illinois have the highest rate of roof fall events due to their weak and severely moisture sensitive roof rock units. Rockmass characterization is the key initial step in designing safe and economical roof control measures in underground coal mines. In this study, a performance-based roof rockmass characterization is investigated. The geologic conditions as well as underground mine geographic specifications, roof fall analysis, mining method, utilized supplemental roof control measures, and geotechnical properties of roof rock units were considered to link the roof performance to rockmass characterization. The coal mine roof rating (CMRR) rockmass characterization method was used to evaluate the roof conditions and roof support design for an underground coal mine located in the Illinois Coal Basin. The results of several mine visit mappings, laboratory test results, and geotechnical issues and concerns are presented and discussed. The roof support designs are analyzed based on the rockmass characterization and are compared with the observed performance. This study shows that (1) CMRR index is a reasonable method for characterizing roof rockmass; (2) moisture sensitivity and bedding strengths in the horizontal direction are essential parameters for roof support design in mines with weak roof conditions; and (3) the applicability of the analysis of roof bolt system for roof support design of the studied mine is questionable.

  16. 33 CFR 100.905 - Door County Triathlon; Door County, WI.

    Science.gov (United States)

    2010-07-01

    ... 33 Navigation and Navigable Waters 1 2010-07-01 2010-07-01 false Door County Triathlon; Door County, WI. 100.905 Section 100.905 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY REGATTAS AND MARINE PARADES SAFETY OF LIFE ON NAVIGABLE WATERS § 100.905 Door County...

  17. Green roof stormwater retention: effects of roof surface, slope, and media depth.

    Science.gov (United States)

    VanWoert, Nicholaus D; Rowe, D Bradley; Andresen, Jeffrey A; Rugh, Clayton L; Fernandez, R Thomas; Xiao, Lan

    2005-01-01

    Urban areas generate considerably more stormwater runoff than natural areas of the same size due to a greater percentage of impervious surfaces that impede water infiltration. Roof surfaces account for a large portion of this impervious cover. Establishing vegetation on rooftops, known as green roofs, is one method of recovering lost green space that can aid in mitigating stormwater runoff. Two studies were performed using several roof platforms to quantify the effects of various treatments on stormwater retention. The first study used three different roof surface treatments to quantify differences in stormwater retention of a standard commercial roof with gravel ballast, an extensive green roof system without vegetation, and a typical extensive green roof with vegetation. Overall, mean percent rainfall retention ranged from 48.7% (gravel) to 82.8% (vegetated). The second study tested the influence of roof slope (2 and 6.5%) and green roof media depth (2.5, 4.0, and 6.0 cm) on stormwater retention. For all combined rain events, platforms at 2% slope with a 4-cm media depth had the greatest mean retention, 87%, although the difference from the other treatments was minimal. The combination of reduced slope and deeper media clearly reduced the total quantity of runoff. For both studies, vegetated green roof systems not only reduced the amount of stormwater runoff, they also extended its duration over a period of time beyond the actual rain event.

  18. Solar roof Spansko-Croatia

    Energy Technology Data Exchange (ETDEWEB)

    Majdandzic, L. [Croatian Professional Society for Solar Energy, Zagreb (Croatia); Peric, M. [Brodarski Institute, Zagreb (Croatia); Matic, Z. [Hrvoje Pozar Energy Institute, Zagreb (Croatia)

    2004-07-01

    This paper presents a project named ''Solar roof Spansko-Zagreb'' with data for half a year of operation. This is the first grid-connected project in the Republic of Croatia. The project comprises of solar collectors providing thermal energy, and of PV modules providing electricity. This building does not emit carbon dioxide into the environment, a major contributor of global warming. The concept shows that passive and active use of solar energy can meet power needs of a building, without disrupting the comfort of habitation. The building reduces consumption of fossil fuels thus reducing the emission of harmful substances into the environment. This project represents an initiative for increased use of solar energy, especially on islands in coastal region and hinterland of Croatia. (orig.)

  19. Decision Guide for Roof Slope Selection

    Energy Technology Data Exchange (ETDEWEB)

    Sharp, T.R.

    1988-01-01

    This decision guide has been written for personnel who are responsible for the design, construction, and replacement of Air Force roofs. It provides the necessary information and analytical tools for making prudent and cost-effective decisions regarding the amount of slope to provide in various roofing situations. Because the expertise and experience of the decision makers will vary, the guide contains both basic slope-related concepts as well as more sophisticated technical data. This breadth of information enables the less experienced user to develop an understanding of roof slope issues before applying the more sophisticated analytical tools, while the experienced user can proceed directly to the technical sections. Although much of this guide is devoted to the analysis of costs, it is not a cost-estimating document. It does, however, provide the reader with the relative costs of a variety of roof slope options; and it shows how to determine the relative cost-effectiveness of different options. The selection of the proper roof slope coupled with good roof design, a quality installation, periodic inspection, and appropriate maintenance and repair will achieve the Air Force's objective of obtaining the best possible roofing value for its buildings.

  20. Construction Guidelines for High R-Value Walls without Exterior Rigid Insulation

    Energy Technology Data Exchange (ETDEWEB)

    Arena, Lois B. [Steven Winter Associates, Inc., Norwalk, CT (United States). Consortium for Advanced Residential Buildings (CARB)

    2016-07-13

    High R-value wall assemblies (R-40 and above) are gaining popularity in the market due to programs such as the U.S. Department of Energy Zero Energy Ready Home program, Passive House, Net Zero Energy Home challenges in several states, and highly incentivized retrofit programs. In response to this demand, several builders have successfully used double-wall systems to achieve higher R-values in thicker, framed walls. To builders of conventional stick-framed homes, often one of the most appealing features of double-wall systems is that there are very few new exterior details. Exterior sheathings, structural bracings, house wraps or building paper, window and door flashings, and siding attachments are usually identical to good details in conventional framed-wall systems. However, although the details in double-wall systems are very similar to those in conventional stick framing, there is sometimes less room for error. Several studies have confirmed colder temperatures of exterior sheathing in high R-value wall assemblies that do not have exterior rigid foam insulation. These colder temperatures can lead to increased chances for condensation from air exfiltration, and they have the potential to result in moisture-related problems (Straube and Smegal 2009, Arena 2014, Ueno 2015). The information presented in this guide is intended to reduce the risk of failure in these types of assemblies, increase durability, and reduce material brought to landfills due to failures and resulting decay. Although this document focuses on double-wall framing techniques, the majority of the information about how to properly construct and finish high R-value assemblies is applicable to all wall assemblies that do not have foam insulation installed on the exterior of the structural sheathing. The techniques presented have been shown through field studies to reduce the likelihood of mold growth and moisture-related damage and are intended for builders, framing contractors, architects, and

  1. Horizontal roof gap of backfill hydraulic support

    Institute of Scientific and Technical Information of China (English)

    张强; 张吉雄; 邰阳; 方坤; 殷伟

    2015-01-01

    For the backfill hydraulic support as the key equipment for achieving integration of backfilling and coal mining simultaneously in the practical process, its characteristics will directly influence the backfill body’s compression ratio. Horizontal roof gap, as a key parameter of backfilling characteristics, may impact the backfilling effect from the aspects of control of roof subsidence in advance, support stress, backfilling process and the support design. Firstly, the reason why horizontal roof gap exists was analyzed and its definition, causes and connotation were introduced, then adopting the Pro/E 3D simulation software, three typical 3D entity models of backfill hydraulic supports were built, based on the influence of horizontal roof gap on backfilling effect, and influence rules of four factors, i.e. support height, suspension height, suspension angle and tamping angle, were emphatically analyzed on horizontal roof gap. The results indicate that, the four factors all have significant impacts on horizontal roof gap, but show differences in influence trend and degree, showing negative linear correlation, positive linear correlation, positive semi-parabolic correlation and negative semi-parabolic correlation, respectively. Four legs type is the most adaptive to the four factors, while six legs (II) type has the poorest adaptability, and the horizontal roof gap is small under large support height, small suspension height, small suspension angle and large tamping angle situation. By means of optimizing structure components and their positional relation and suspension height of backfill scrape conveyor in the process of support design and through controlling working face deployment, roof subsidence in advance, mining height and backfilling during engineering application, the horizontal roof gap is optimized. The research results can be served as theoretical basis for support design and guidance for backfill support to have better performance in backfilling.

  2. 29 CFR 1917.114 - Cargo doors.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Cargo doors. 1917.114 Section 1917.114 Labor Regulations Relating to Labor (Continued) OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR (CONTINUED) MARINE TERMINALS Terminal Facilities § 1917.114 Cargo doors. (a) Mechanically operated. (1) Cargo...

  3. Goedkopere weefselkweekplantjes door kweek in het donker

    NARCIS (Netherlands)

    Klerk, de G.J.M.

    2007-01-01

    Weefselkweek is duur. Daardoor zijn voordelen van weefselvermeerdering maar bij een klein aantal gewassen te benutten. Tot nu toe zijn de kosten teruggbracht door stoomlijnen van de productie en door overbrengen van de bulkproductie naar lagelonenlanden. Er zijn pogingen geweest het weefselkweekproc

  4. Outsourcing van het ICT door overheidsinstellingen

    NARCIS (Netherlands)

    Kok, L.; Theeuwes, J.J.M.; Janssens, L.

    2003-01-01

    Het IWI heeft onlangs gewezen op de risico’s van outsourcing van ICT door het UWV. Ook het uitbesteden van ICT door gemeenten is niet zonder risico. Om outsourcingsbeslissingen van gemeenten en UWV te kunnen beoordelen wil het ministerie meer inzicht in de effecten van outsourcing. De directie

  5. STUDY ON HARD ROOF ROCKBURST IN COAL MINE

    Institute of Scientific and Technical Information of China (English)

    潘一山; 陈德军; 章梦涛

    1997-01-01

    Based on practical observation in Mentougou Mine, a general law of roof rockburst is put forward. The destabilization theory of roof rockburst has been established. The general laws of microquake premonition and earth sound in roof rockburst is advanced. The relationship between roof rockburst and rockburst of coal body is studied.

  6. Analysis on thermal measuring of green roof

    Institute of Scientific and Technical Information of China (English)

    唐鸣放; 蒋琳

    2009-01-01

    Comparison of thermal performance between a green roof room and a bare roof room was presented during the cooling period in Shanghai. The results show that the electricity can be saved about 0.08 kW·h/(d·m2),and the heat flux can be reduced by about 70%; the inner surface temperature variation is about 1.0 ℃ comparing with the indoor temperature when using the green roof,and the extra equivalent heat resistance is 1.0 m2·K/W.

  7. Metal and nutrient dynamics on an aged intensive green roof.

    Science.gov (United States)

    Speak, A F; Rothwell, J J; Lindley, S J; Smith, C L

    2014-01-01

    Runoff and rainfall quality was compared between an aged intensive green roof and an adjacent conventional roof surface. Nutrient concentrations in the runoff were generally below Environmental Quality Standard (EQS) values and the green roof exhibited NO3(-) retention. Cu, Pb and Zn concentrations were in excess of EQS values for the protection of surface water. Green roof runoff was also significantly higher in Fe and Pb than on the bare roof and in rainfall. Input-output fluxes revealed the green roof to be a potential source of Pb. High concentrations of Pb within the green roof soil and bare roof dusts provide a potential source of Pb in runoff. The origin of the Pb is likely from historic urban atmospheric deposition. Aged green roofs may therefore act as a source of legacy metal pollution. This needs to be considered when constructing green roofs with the aim of improving pollution remediation.

  8. APPLICATIONS OF FRACTIONAL EXTERIOR DIFFERENTIAL IN THREE-DIMENSIONAL SPACE

    Institute of Scientific and Technical Information of China (English)

    陈勇; 闫振亚; 张鸿庆

    2003-01-01

    A brief survey of fractional calculus and fractional differential forms was firstly given. The fractional exterior transition to curvilinear coordinate at the origin were discussed and the two coordinate transformations for the fractional differentials for three-dimensional Cartesian coordinates to spherical and cylindrical coordinates are obtained, respectively. In particular, for v = m = 1 , the usual exterior transformations, between the spherical coordinate and Cartesian coordinate, as well as the cylindrical coordinate and Cartesian coordinate, are found respectively, from fractional exterior transformation.

  9. Hydrologic Restoration in the Urban Environment Using Green Roofs

    OpenAIRE

    Anna Palla; Ilaria Gnecco; Luca G. Lanza

    2010-01-01

    Loss of natural soil and vegetation within the urban environment can significantly affect the hydrologic cycle by increasing storm water runoff rates and volumes. In order to mitigate these modifications in urban areas engineered systems are developed, such as green roofs, to mimic and replace functions (evapo-transpiration, infiltration, percolation) which have been altered due to the impact of human development. Green roofs, also known as vegetated roof covers, eco-roofs or nature roofs, ar...

  10. Building Integrated Photovoltaic (BIPV) Roofs for Sustainability and Energy Efficiency

    Science.gov (United States)

    2014-04-01

    conventional dark roofs, but the degradation in the first few years was significant. This was primarily due to soiling and not actual roof membrane... degradation . Since roof cleaning is not a typical DoD operations or maintenance activity, roof reflectivity was measured with the soiling during the...Roof albedo was originally planned to be measured for only Site III (MCAS Yuma), but since there were different soiling /aging/ degradation conditions

  11. Improving the durability of flat roof constructions

    DEFF Research Database (Denmark)

    Rudbeck, Claus Christian; Svendsen, Sv Aa Højgaard

    1999-01-01

    Flat roof constructions are mainly used on commercial, institutional and industrial buildings, where insulation is placed on top of the load-bearing deck and then covered with a roof membrane. Through time, there is a risk that the membrane will allow water passage as holes might form due...... as there is no easy method of drying it. To be able to dry the insulation, and thereby regain the functional requirements of the roofing system, two new solutions for insulating flat roofs with existing materials are proposed for high density mineral wool and expanded polystyrene. Monitoring equipment are part...... to weathering effects or physical loads. Water will then enter the insulation, and as a vapor retarder is normally found below the insulation thus trapping the water in the insulation, the leak can remain undetected for a long period. When the leak is finally discovered, the insulation has to be discharged...

  12. Carbon sequestration potential of extensive green roofs.

    Science.gov (United States)

    Getter, Kristin L; Rowe, D Bradley; Robertson, G Philip; Cregg, Bert M; Andresen, Jeffrey A

    2009-10-01

    Two studies were conducted with the objective of quantifying the carbon storage potential of extensive green roofs. The first was performed on eight roofs in Michigan and four roofs in Maryland, ranging from 1 to 6 years in age. All 12 green roofs were composed primarily of Sedum species, and substrate depths ranged from 2.5 to 12.7 cm. Aboveground plant material was harvested in the fall of 2006. On average, these roofs stored 162 g C x m(-2) in aboveground biomass. The second study was conducted on a roof in East Lansing, MI. Twenty plots were established on 21 April 2007 with a substrate depth of 6.0 cm. In addition to a substrate only control, the other plots were sown with a single species of Sedum (S. acre, S. album, S. kamtshaticum, or S. spurium). Species and substrate depth represent typical extensive green roofs in the United States. Plant material and substrate were harvested seven times across two growing seasons. Results at the end of the second year showed that aboveground plant material storage varied by species, ranging from 64 g C x m(-2) (S. acre) to 239 g C x m(-2) (S. album), with an average of 168 g C x m(-2). Belowground biomass ranged from 37 g C x m(-2) (S. acre) to 185 g C x m(-2) (S. kamtschaticum) and averaged 107 g C x m(-2). Substrate carbon content averaged 913 g C x m(-2), with no species effect, which represents a sequestration rate of 100 g C x m(-2) over the 2 years of this study. The entire extensive green roof system sequestered 375 g C x m(-2) in above- and belowground biomass and substrate organic matter.

  13. Green Roofs and Green Building Rating Systems

    OpenAIRE

    Liaw; Chao-Hsien

    2015-01-01

    The environmental benefits for green building from the Leadership in Energy and Environment Design (LEED) and Ecology, Energy, Waste, and Health (EEWH) rating systems have been extensively investigated; however, the effect of green roofs on the credit-earning mechanisms is relatively unexplored. This study is concerned with the environmental benefits of green roofs with respect to sustainability, stormwater control, energy savings, and water resources. We focused on the relationsh...

  14. Cladding Attachment Over Thick Exterior Insulating Sheathing

    Energy Technology Data Exchange (ETDEWEB)

    Baker, P.; Eng, P.; Lepage, R.

    2014-01-01

    The addition of insulation to the exterior of buildings is an effective means of increasing the thermal resistance of both wood framed walls as well as mass masonry wall assemblies. For thick layers of exterior insulation (levels greater than 1.5 inches), the use of wood furring strips attached through the insulation back to the structure has been used by many contractors and designers as a means to provide a convenient cladding attachment location (Straube and Smegal 2009, Pettit 2009, Joyce 2009, Ueno 2010). The research presented in this report is intended to help develop a better understanding of the system mechanics involved and the potential for environmental exposure induced movement between the furring strip and the framing. BSC sought to address the following research questions: 1. What are the relative roles of the mechanisms and the magnitudes of the force that influence the vertical displacement resistance of the system? 2. Can the capacity at a specified deflection be reliably calculated using mechanics based equations? 3. What are the impacts of environmental exposure on the vertical displacement of furring strips attached directly through insulation back to a wood structure?

  15. Cladding Attachment Over Thick Exterior Insulating Sheathing

    Energy Technology Data Exchange (ETDEWEB)

    Baker, P. [Building Science Corporation, Somerville, MA (United States); Eng, P. [Building Science Corporation, Somerville, MA (United States); Lepage, R. [Building Science Corporation, Somerville, MA (United States)

    2014-01-01

    The addition of insulation to the exterior of buildings is an effective means of increasing the thermal resistance of both wood framed walls as well as mass masonry wall assemblies. For thick layers of exterior insulation (levels greater than 1.5 inches), the use of wood furring strips attached through the insulation back to the structure has been used by many contractors and designers as a means to provide a convenient cladding attachment location (Straube and Smegal 2009, Pettit 2009, Joyce 2009, Ueno 2010). The research presented in this report is intended to help develop a better understanding of the system mechanics involved and the potential for environmental exposure induced movement between the furring strip and the framing. BSC sought to address the following research questions: 1.What are the relative roles of the mechanisms and the magnitudes of the force that influence the vertical displacement resistance of the system? 2.Can the capacity at a specified deflection be reliably calculated using mechanics based equations? 3.What are the impacts of environmental exposure on the vertical displacement of furring strips attached directly through insulation back to a wood structure?

  16. Six aspects to inspirational green roof design

    Energy Technology Data Exchange (ETDEWEB)

    Kiers, H. [SWA Group, Sausalito, CA (United States)

    2004-07-01

    Green roofs have been categorized as a technology that is not initially faster, better or cheaper, and may even under perform established products. However, green roofs have features and values that early adopters are ready to experiment with in small markets, thereby creating awareness of the technology. Termed as disruptive technologies, green roofs can become competitive within the mainstream market against established products. The challenge in green roof construction is to find the correct balance between idealistic principles and leading edge design. This paper presented case studies to examine the following 6 aspects of design fundamentals to the creation of inspirational green roofs: the use of colour; experimentation with materials and technology; incorporation of texture, form, and pattern; definition of space; engagement of vistas; and, principles of bio-regionalism. It was concluded that good design is not enough to lead to widespread green roof implementation. It was emphasized that change will occur primarily because of the benefits acquired through implementation. 11 refs., 7 figs.

  17. An unexpected knock on Corrigan's secret door.

    Science.gov (United States)

    Woywodt, Alexander

    2010-10-01

    Corrigan's secret door describes a metaphorical escape route for busy physicians. The term was derived from the successful and exceptionally busy professional life of Irish physician Dominic John Corrigan (1802-80). It is claimed that Corrigan's outpatient clinic was so busy that he required a secret door in his consulting rooms to escape from the ever-growing queue of eager patients. The origins of this charming story are unknown, and the door may have never existed. However, at present, Corrigan's secret door is often quoted when busy physicians have their own little ways in surviving a stressful professional life. Generations of British-trained doctors have grown up with Corrigan's secret door, as it was featured in the introduction of the Oxford Handbook of Clinical Medicine. Accordingly, trainees as well as more senior doctors are often reminded that having a 'secret door' is vital in surviving in the medical profession. My own escape is through classical music and the violoncello, in particular. As the name implies, my own secret door is normally invisible to colleagues and patients. This little article is about a patient who found me out, and a reflection on the role of classical music and the cello in my professional life.

  18. Building America Case Study: Construction Guidelines for High R-Value Walls without Exterior Rigid Insulation, Cold Climate Region

    Energy Technology Data Exchange (ETDEWEB)

    2017-01-01

    High-R wall assemblies (R-40 and above) are gaining popularity in the market due to programs like the DOE's Zero Energy Ready Home program, Passive House (PH), Net Zero Energy Home (NZEH) challenges in several states, and highly incentivized retrofit programs. In response to this demand, several builders have successfully used 'double wall' systems to more practically achieve higher R-values in thicker, framed walls. To builders of conventional stick-framed homes, often one of the most appealing features of double wall systems is that there are very few new exterior details. Exterior sheathing, structural bracing, house wrap or building paper, window and door flashing, and siding attachment are usually identical to good details in conventional framed wall systems. The information presented in this guide is intended to reduce the risk of failure in these types of assemblies, increase durability, and result in a reduction of material brought to landfills due to failures and resulting decay. While this document focuses on double wall framing techniques, the majority of the information on how to properly construct and finish high R-value assemblies is applicable to all wall assemblies that do not have foam insulation installed on the exterior of the structural sheathing. The techniques presented have been shown through field studies to reduce the likelihood of mold growth and moisture related damage and are intended for builders, framing contractors, architects, and consultants involved in designing and building super insulated homes.

  19. Building America Case Study: Construction Guidelines for High R-Value Walls without Exterior Rigid Insulation, Cold Climate Region

    Energy Technology Data Exchange (ETDEWEB)

    L. Arena

    2017-01-01

    High-R wall assemblies (R-40 and above) are gaining popularity in the market due to programs like the DOE's Zero Energy Ready Home program, Passive House (PH), Net Zero Energy Home (NZEH) challenges in several states, and highly incentivized retrofit programs. In response to this demand, several builders have successfully used 'double wall' systems to more practically achieve higher R-values in thicker, framed walls. To builders of conventional stick-framed homes, often one of the most appealing features of double wall systems is that there are very few new exterior details. Exterior sheathing, structural bracing, house wrap or building paper, window and door flashing, and siding attachment are usually identical to good details in conventional framed wall systems. The information presented in this guide is intended to reduce the risk of failure in these types of assemblies, increase durability, and result in a reduction of material brought to landfills due to failures and resulting decay. While this document focuses on double wall framing techniques, the majority of the information on how to properly construct and finish high R-value assemblies is applicable to all wall assemblies that do not have foam insulation installed on the exterior of the structural sheathing. The techniques presented have been shown through field studies to reduce the likelihood of mold growth and moisture related damage and are intended for builders, framing contractors, architects, and consultants involved in designing and building super insulated homes.

  20. Cost Comparative Study On Steel Frame Folded Plate Roofing System Vs Conventional Truss Roofing System

    Directory of Open Access Journals (Sweden)

    T. Subramani

    2014-12-01

    Full Text Available Due to ever-increasing of construction materials, it becomes the foremost duty of a civil engineer to design economical and durable structures. In this project an attempt has been made to compare the cost of two types of roofing systems viz. conventional truss roofing system and steel frame folded plate roofing system. The steel frame folded plate roofing system, though found to be economical, is not widely practiced in India due to lack of knowledge regarding its analysis and design. On contrary to it, the conventional truss roofing system still remains as the widely adopted method of roofing for different types of buildings due to the available literature on its analysis, design and construction. The analysis and design of conventional truss roofing system and folded plate roofing system have been carried out for various spans. The analysis is carried out in STAAD.Pro 2004, which is based on stiffness method. Load calculations and design done manually, based on IS:875-1987, IS:800- 1984 & SP:38(1987

  1. A case of possessive state with onset influenced by 'door-to-door' sales.

    Science.gov (United States)

    Satoh, S; Obata, S; Seno, E; Okada, T; Morita, N; Saito, T; Yoshikawa, M; Yamagami, A

    1996-12-01

    Recently in Japan, 'door-to-door sales' has become of concern because it has created numerous legal and social problems. In this paper, a 47 year old dissociative trance disorder case who presented with possession by God is discussed. Specific types of door-to-door sales is known to use superstition and folk beliefs as tools to lure customers. In this particular case, these religious factors seemed to have played an important role in the precipitation of the disorder and its presentation. In addition, the brain-washing environment observed in video lectures used in door-to-door sales seemed to play an important role in the development of the possessive state. We also performed social psychiatric analysis of the occurrence of the possessive state in a city area, which has been considered to develop within traditional culture. Phenomenological classification by one of the authors was useful for diagnosing underlying disorders in the possessive state.

  2. Energy Roof. A waterproof and efficient solution for sustainable energy; Energiedak. Een waterdichte en voordelige oplossing voor duurzame energie

    Energy Technology Data Exchange (ETDEWEB)

    Schiebroek, A. [SolarTech International, Eindhoven (Netherlands)

    2013-06-15

    An Energy Roof is an effective and economically efficient system to compensate heat loss in the underground. It concerns a tube system on the roof which contains cold water that is heated by the sun, balancing the underground storage. A good system to control the flow is key to a sustainable climate installation for heating and cooling [Dutch] Een Energiedak is een effectief en economisch rendabel systeem om de onttrekking van warmte aan de bodem op een efficiente wijze te compenseren. Het betreft een buizensysteem op het dak waar koud water doorheen vloeit, dat door de zon wordt opgewarmd en de ondergrondse bron in balans houdt. Een goede regeling om de stroomsnelheid te beinvloeden vormt het sluitstuk van een duurzaam klimaatsysteem voor verwarming en koeling.

  3. September 2013: the doors open

    CERN Multimedia

    Antonella Del Rosso

    2013-01-01

    Three special days and one public open day: at the end of September our Laboratory will open its doors to visitors from CERN, the local region and all over the world. With over 150,000 visitors expected in total, the organisation of the OpenDays is a challenge that a core team of eleven people have taken up with enthusiasm.   They come from several departments but share one goal: making the last four days of September an unforgettable experience for all the visitors who will come to discover the Laboratory and its scientists. The core team in charge of the organisation of the events is co-ordinated by Hermann Schmickler. “The events are an opportunity for us to celebrate  the discoveries, the excellent performance of the technical installations and the vital contribution of all the CERN personnel, the thousands of users and those working under support contracts,” says Hermann Schmickler. The four-day programme will start on Friday 27 September with an “...

  4. The Globe reopens its doors

    CERN Multimedia

    CERN Bulletin

    2016-01-01

    After a year of work, the newly renovated Globe of Science and Innovation will open its doors again at 10 a.m. on Tuesday, 19 April. The “Universe of Particles” exhibition has been updated and will be open to the public, free of charge, from 10 a.m. to 5 p.m., Monday to Saturday (except during official CERN closures). The Globe’s programme of lectures and events for the general public will restart at the end of April. What’s on at the Globe in April and May: - 28 April at 6.30 p.m.: Theatre – “Curie_Meitner_Lamarr_indivisible”, a play that pays tribute to the lives of three exceptional women in the field of science and technology (in English). Reservations: http://indico.cern.ch/e/cmli - 10 May at 8.30 p.m.: Lecture – “Le modèle du CERN et les grands défis mondiaux” (“The CERN model and the key global challenges”) by Michel Spiro (in French with simultaneous ...

  5. Green roof valuation: a probabilistic economic analysis of environmental benefits.

    Science.gov (United States)

    Clark, Corrie; Adriaens, Peter; Talbot, F Brian

    2008-03-15

    Green (vegetated) roofs have gained global acceptance as a technologythat has the potential to help mitigate the multifaceted, complex environmental problems of urban centers. While policies that encourage green roofs exist atthe local and regional level, installation costs remain at a premium and deter investment in this technology. The objective of this paper is to quantitatively integrate the range of stormwater, energy, and air pollution benefits of green roofs into an economic model that captures the building-specific scale. Currently, green roofs are primarily valued on increased roof longevity, reduced stormwater runoff, and decreased building energy consumption. Proper valuation of these benefits can reduce the present value of a green roof if investors look beyond the upfront capital costs. Net present value (NPV) analysis comparing a conventional roof system to an extensive green roof system demonstrates that at the end of the green roof lifetime the NPV for the green roof is between 20.3 and 25.2% less than the NPV for the conventional roof over 40 years. The additional upfront investment is recovered at the time when a conventional roof would be replaced. Increasing evidence suggests that green roofs may play a significant role in urban air quality improvement For example, uptake of N0x is estimated to range from $1683 to $6383 per metric ton of NOx reduction. These benefits were included in this study, and results translate to an annual benefit of $895-3392 for a 2000 square meter vegetated roof. Improved air quality leads to a mean NPV for the green roof that is 24.5-40.2% less than the mean conventional roof NPV. Through innovative policies, the inclusion of air pollution mitigation and the reduction of municipal stormwater infrastructure costs in economic valuation of environmental benefits of green roofs can reduce the cost gap that currently hinders U.S. investment in green roof technology.

  6. 10 CFR 434.516 - Building exterior envelope.

    Science.gov (United States)

    2010-01-01

    ... Buildings for calculating the Energy Cost Budget. In calculating the Design Energy Consumption of the... 10 Energy 3 2010-01-01 2010-01-01 false Building exterior envelope. 434.516 Section 434.516 Energy... RESIDENTIAL BUILDINGS Building Energy Cost Compliance Alternative § 434.516 Building exterior envelope....

  7. Exterior and interior metrics with quadrupole moment

    CERN Document Server

    Quevedo, Hernando

    2010-01-01

    We present the Ernst potential and the line element of an exact solution of Einstein's vacuum field equations that contains as arbitrary parameters the total mass, the angular momentum, and the quadrupole moment of a rotating mass distribution. We show that in the limiting case of slowly rotating and slightly deformed configuration, there exists a coordinate transformation that relates the exact solution with the approximate Hartle solution. It is shown that this approximate solution can be smoothly matched with an interior perfect fluid solution with physically reasonable properties. This opens the possibility of considering the quadrupole moment as an additional physical degree of freedom that could be used to search for a realistic exact solution, representing both the interior and exterior gravitational field generated by a self-gravitating axisymmetric distribution of mass of perfect fluid in stationary rotation.

  8. Retention capacity of extensive green roofs

    Directory of Open Access Journals (Sweden)

    Sobczyk Małgorzata

    2016-09-01

    Full Text Available Climate change causes a more frequent occurrence of extreme events. The result of these phenomena is the occurrence of floods and flooding, and periods of drought. Particularly unfavorable is intensive rainfall over the urban catchments. To prevent the negative consequences of these phenomena, unconventional solutions should be used. The use of green roofs in urban areas will serve the sustainable development of cities and the impact on local ecological changes. The study was performed at two green roof platforms 1.2×1.2×0.1 m each. An analysis was performed at different intensities given for precipitation. 20 min for the rain to stop was observed from 68 to 100% precipitation. The study was divided into two parts. The first part of the study has been performed in the dry period. In contrast, another round of tests was repeated in other conditions after rainfall. The amount of water at two experimental green roofs platforms before the test was 11.0 dm3. The research relates to the impact of green roofs on local hydrological changes. Development of technologies for green roofs had a positive impact on mitigating the effects of climate change associated with the occurrence of flooding the city.

  9. Integrated real-time roof monitoring

    Institute of Scientific and Technical Information of China (English)

    SHEN Bao-tang; GUO Hua; KING Andrew

    2009-01-01

    CSIRO has recently developed a real-time roof monitoring system for under-ground coal mines and successfully tried the system in gate roads at Ulan Mine. The sys-tem integrated displacement monitoring, stress monitoring and seismic monitoring in one package. It included GEL multianchor extensometers, vibrating wire uniaxial stress meters, ESG seismic monitoring system with microseismic sensors and high-frequency AE sen-sors. The monitoring system automated and the data can be automatically collected by a central computer located in an underground nonhazardous area. The data are then trans-ferred to the surface via an optical fiber cable. The real-time data were accessed at any location with an Internet connection. The trials of the system in two tailgates at Ulan Mine demonstrate that the system is effective for monitoring the behavior and stability of read-ways during Iongwall mining. The continuous roof displacement/stress data show clear precursors of roof falls. The seismic data (event count and locations) provide insights into the roof failure process during roof fall.

  10. Fuel Consumption Impacts of Auto Roof Racks

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Yuche; Meier, Alan

    2016-05-01

    The after-market roof rack is one of the most common components attached to a vehicle for carrying over-sized items, such as bicycles and skis. It is important to understand these racks' fuel consumption impacts on both individual vehicles and the national fleet because they are widely used. We estimate the national fuel consumption impacts of roof racks using a bottom-up approach. Our model incorporates real-world data and vehicle stock information to enable assessing fuel consumption impacts for several categories of vehicles, rack configurations, and usage conditions. In addition, the model draws on two new data-gathering techniques, on-line forums and crowd-sourcing. The results show that nationwide, roof racks are responsible for 0.8% of light duty vehicle fuel consumption in 2015, corresponding to 100 million gallons of gasoline per year. Sensitivity analyses show that results are most sensitive to the fraction of vehicles with installed roof racks but carrying no equipment. The aerodynamic efficiency of typical roof racks can be greatly improved and reduce individual vehicle fuel consumption; however, government policies to minimize extensive driving with empty racks--if successful--could save more fuel nationally.

  11. Vraaggericht werken door narratief onderzoek

    Directory of Open Access Journals (Sweden)

    Joos Meesters

    2010-09-01

    Full Text Available Narrative research as a means for demand-driven policy and interventions This article reports on the advantages of performing narrative research discovering need patterns of families, children, local residents regarding quality of the pedagogical climate in their neighbourhood. A need pattern is a constructed set of related questions and needs that people express in response to life events, concrete experiences or within their current habitat. A method for narrative analysis was developed for two applications: use as a research tool and use as a change management tool. In this method professionals assume the role of narrative researchers and simultaneously learn to listen to the demands and needs of their potential clients from a more objective perspective. The method has been developed while performing transdisciplinary narrative research in the town-area of Hatert in Nijmegen, which will be presented as an example case throughout the text. Vraaggericht werken door narratief onderzoek Dit artikel gaat in op de mogelijkheden van narratief onderzoek in het opsporen van vraagpatronen van gezinnen, kinderen, wijkbewoners met betrekking tot de kwaliteit van het opgroeiklimaat in hun wijk. Een vraagpatroon is een set van samenhangende vragen en behoeften die burgers uiten naar aanleiding van een levensgebeurtenis, een concrete ervaring of binnen de actuele context waar zij in leven. Voor deze vorm van onderzoek is een vraaganalyse-instrument ontwikkeld om deze vraagpatronen te identificeren. Dit instrument heeft een dubbel perspectief. Het is een onderzoeksinstrument en een veranderkundig instrument. De professional kruipt in de rol van onderzoeker en leert hiermee te luisteren naar de vragen en behoeften van burgers. Het instrument is ontwikkeld in en voor een transdisciplinair, narratief onderzoek in de wijk Hatert in Nijmegen, dat we als casus zullen presenteren.

  12. Roofing as a source of nonpoint water pollution.

    Science.gov (United States)

    Chang, Mingteh; McBroom, Matthew W; Scott Beasley, R

    2004-12-01

    Sixteen wooden structures with two roofs each were installed to study runoff quality for four commonly used roofing materials (wood shingle, composition shingle, painted aluminum, and galvanized iron) at Nacogdoches, Texas. Each roof, either facing NW or SE, was 1.22 m wide x 3.66 m long with a 25.8% roof slope. Thus, there were 32 alternatively arranged roofs, consisting of four roof types x two aspects x four replicates, in the study. Runoff from the roofs was collected through galvanized gutters, downspouts, and splitters. The roof runoff was compared to rainwater collected by a wet/dry acid rain collector for the concentrations of eight water quality variables, i.e. Cu(2+), Mn(2+), Pb(2+), Zn(2+), Mg(2+), Al(3+), EC and pH. Based on 31 storms collected between October 1997 and December 1998, the results showed: (1) concentrations of pH, Cu, and Zn in rainwater already exceed the EPA freshwater quality standards even without pollutant inputs from roofs, (2) Zn and Cu, the two most serious pollutants in roof runoff, exceeded the EPA national freshwater water quality standards in virtually 100% and more than 60% of the samples, respectively, (3) pH, EC, and Zn were the only three variables significantly affected by roofing materials, (4) differences in Zn concentrations were significant among all roof types and between all roof runoff and rainwater samples, (5) although there were no differences in Cu concentrations among all roof types and between roof runoff and rainwater, all means and medians of runoff and rainwater exceeded the national water quality standards, (6) water quality from wood shingles was the worst among the roof types studied, and (7) although SE is the most frequent and NW the least frequent direction for incoming storms, only EC, Mg, Mn, and Zn in wood shingle runoff from the SE were significantly higher than those from the NW; the two aspects affected no other elements in runoff from the other three roof types. Also, Zn concentrations from

  13. Green Roofs and Green Building Rating Systems

    Directory of Open Access Journals (Sweden)

    Liaw

    2015-01-01

    Full Text Available The environmental benefits for green building from the Leadership in Energy and Environment Design (LEED and Ecology, Energy, Waste, and Health (EEWH rating systems have been extensively investigated; however, the effect of green roofs on the credit-earning mechanisms is relatively unexplored. This study is concerned with the environmental benefits of green roofs with respect to sustainability, stormwater control, energy savings, and water resources. We focused on the relationship between green coverage and the credits of the rating systems, evaluated the credits efficiency, and performed cost analysis. As an example, we used a university building in Keelung, Northern Taiwan. The findings suggest that with EEWH, the proposed green coverage is 50–75%, whereas with LEED, the proposed green coverage is 100%. These findings have implications for the application of green roofs in green building.

  14. Flat roof integration. CPT solar (AET IV)

    Energy Technology Data Exchange (ETDEWEB)

    Chianese, D.; Pola, I.; Bernasconi, A.; Bura, E.; Cereghetti, N.; Realini, A.; Pasinelli, P.; Rioggi, S.

    2007-11-15

    This illustrated final report for the Swiss Federal Office of Energy (SFOE) takes a look at a 15.4 kWp solar power installation in Trevano, Switzerland, that features flexible amorphous silicon triple-junction modules, mounted nearly horizontally and directly laminated to flexible polyolefin membranes that form the covering of a flat roof. The main objective of this study was to verify in which order of magnitude the better thermal behaviour of amorphous silicon cells can compensate for losses due to the quasi-horizontal roof integration (lower irradiation and higher reflection), and thus be competitive in the flat roof construction and refurbishment markets. The modules used and their characteristics are described. Performance, temperature levels and energy-production are reviewed for the panels of the installation. The performance of the inverter used is also reviewed. Data on temperatures and production are presented in graphical form and optical losses are examined.

  15. Weathering of Roofing Materials-An Overview

    Energy Technology Data Exchange (ETDEWEB)

    Berdahl, Paul; Akbari, Hashem; Levinson, Ronnen; Miller, William A.

    2006-03-30

    An overview of several aspects of the weathering of roofing materials is presented. Degradation of materials initiated by ultraviolet radiation is discussed for plastics used in roofing, as well as wood and asphalt. Elevated temperatures accelerate many deleterious chemical reactions and hasten diffusion of material components. Effects of moisture include decay of wood, acceleration of corrosion of metals, staining of clay, and freeze-thaw damage. Soiling of roofing materials causes objectionable stains and reduces the solar reflectance of reflective materials. (Soiling of non-reflective materials can also increase solar reflectance.) Soiling can be attributed to biological growth (e.g., cyanobacteria, fungi, algae), deposits of organic and mineral particles, and to the accumulation of flyash, hydrocarbons and soot from combustion.

  16. Effects of roof and rainwater characteristics on copper concentrations in roof runoff.

    Science.gov (United States)

    Bielmyer, Gretchen K; Arnold, W Ray; Tomasso, Joseph R; Isely, Jeff J; Klaine, Stephen J

    2012-05-01

    Copper sheeting is a common roofing material used in many parts of the world. However, copper dissolved from roof sheeting represents a source of copper ions to watersheds. Researchers have studied and recently developed a simple and efficient model to predict copper runoff rates. Important input parameters include precipitation amount, rain pH, and roof angle. We hypothesized that the length of a roof also positively correlates with copper concentration (thus, runoff rates) on the basis that runoff concentrations should positively correlate with contact time between acidic rain and the copper sheet. In this study, a novel system was designed to test and model the effects of roof length (length of roof from crown to the drip edge) on runoff copper concentrations relative to rain pH and roof angle. The system consisted of a flat-bottom copper trough mounted on an apparatus that allowed run length and slope to be varied. Water of known chemistry was trickled down the trough at a constant rate and sampled at the bottom. Consistent with other studies, as pH of the synthetic rainwater decreased, runoff copper concentrations increased. At all pH values tested, these results indicated that run length was more important in explaining variability in copper concentrations than was the roof slope. The regression equation with log-transformed data (R(2) = 0.873) accounted for slightly more variability than the equation with untransformed data (R(2) = 0.834). In log-transformed data, roof angle was not significant in predicting copper concentrations.

  17. Quality of Rainwater from Different Roof Material

    Directory of Open Access Journals (Sweden)

    Olaoye, R.A

    2012-08-01

    Full Text Available Roof material is an important consideration when designing a rainwater catchment system .This is because it affects the quality of the harvested rainwater which invariably affects the usage as potable or non potable.This study was carried out to determine the quality of rainwater from four different roofing materials (asbestos, aluminium, concrete and corrugated plastic within Ogbomosho North Local Government Area of Oyo State, Nigeria, between the months of July to October, 2011. The rainwater samples were taken to the laboratory and analyzed as recommended by Nigerian standard for Drinking Water Quality (NSDQW and World Health Organization (WHO.All the Physical and most of the chemical parameters analyzed conformed to the recommended standard value apart from chloride and total hardness value. Of interest is the rainwater sample from asbestos roofing sheet which had the highest mean value for pH (6.75, total hardness (84 – 86mg/l, aluminium concentration (3 – 9 mg/l, copper (0.03 – 0.04 mg/l, nitrate (31.9 – 39mg/l, and sulphate value between 11- 14mg/l, although, all these parameters fell within the standard values. However, Coliform as bacterial indicator was present in samples from asbestos, concrete and corrugated plastic roof, only the aluminium roof was free from pathogenic contamination. To ensure that the rainwater harvested satisfies health requirement for consumption as specified, all the harvested rainwater should be given some level of treatment in terms of pH, total hardness, chloride concentration and bacterial contamination. It was recommended that the rainwater from all the roofs in this case study area, be carefully examined. Consequently, if the harvested rainwater is being considered for domestic use, the gutters and the catchment areas should be regularly cleaned to remove animal droppings and leaves from over hanging trees as well as boiled to adequate temperature.

  18. Weak roof fall simulation for a longwall face

    Energy Technology Data Exchange (ETDEWEB)

    Nazimko, V.V.; Khalimendick, U.M.; Zborshtchick, M.P.; Danilov, V.K.; Sugakov, V.A. [Donetsk State Technical University, Donetsk (Ukraine)

    1999-07-01

    A particle flow algorithm has been employed to investigate immediate roof stability. It is demonstrated that weak rock layers and a lack of powered supports are the most important factors which impact stability to the roof. 1 ref., 4 figs.

  19. Thermoplastic Single-Ply Roof Relieves Water Damage and Inconvenience.

    Science.gov (United States)

    Williams, Jennifer Lynn

    2002-01-01

    Assesses use of thermoplastic single-ply roofs by North Carolina's Mars Hill College to prevent leaks, reduce maintenance costs, and enhance the value of their older historic buildings. Administrators comment on the roof's installation efficiency and cleanliness. (GR)

  20. Stability analysis of subgrade cave roofs in karst region

    Institute of Scientific and Technical Information of China (English)

    蒋冲; 赵明华; 曹文贵

    2008-01-01

    According to the engineering features of subgrade cave roof in karst region, the clamped beam model of subgrade cave roof in karst region was set up. Based on the catastrophe theory, the cusp catastrophe model for bearing capacity of subgrade cave roof and safe thickness of subgrade cave roof in karst region was established. The necessary instability conditions of subgrade cave roof were deduced, and then the methods to determine safe thickness of cave roofs under piles and bearing capacity of subgrade cave roof were proposed. At the same time, a practical engineering project was applied to verifying this method, which has been proved successfu1ly. At last, the major factors that affect the stability on cave roof under pile in karst region were deeply discussed and some results in quality were acquired.

  1. 49 CFR 571.206 - Standard No. 206; Door locks and door retention components.

    Science.gov (United States)

    2010-10-01

    ... can be loaded or unloaded. It does not include: (a) A trunk lid; or (b) A door or window composed... the door in the fully latched or secondary latched position. Trunk Lid is a movable body panel that... minimum displacement of 300 mm. (c) Two load cells of sufficient capacity to measure the applied loads...

  2. Electric two wheelers, zero emission solution for urban door to door transportation

    DEFF Research Database (Denmark)

    Fasil, Muhammed; Jensen, Bogi Bech

    The noise and exhaust pollution coupled with increasing congestion faced by urban centres demands new personal mobility solution for faster door to door connectivity. The advancement in electric power train and lowering cost of Li-ion battery is made it possible to develop light weight fully...

  3. Roof separation characteristics of laminated weak roof strata of longwall roadway

    Institute of Scientific and Technical Information of China (English)

    LU Ting-kan; LIU Yu-zhou

    2004-01-01

    The roof separation was investigated in a coal mine as part of the site characterization of roof strata deterioration in a longwall roadway. The separation of laminated,weak roof strata was initially characterized as the maximum separation, effect of geological setting on separation and the effect of mining activities (heading development,time-dependent and longwall extraction) on separation. Then the separation process was studied, so as to answer the questions of: when the separation occurs; where the separation is located and what geological setting it relates to; how large of the separation is; and how the separation propagates.

  4. The Benefits of Green Roofing for Latvian Building Environment

    OpenAIRE

    Kara, P.; Pastars, P

    2013-01-01

    Green roofs serve several purposes for a building, such as absorbing rainwater, providing insulation, creating a habitat for wildlife and helping to lower urban air temperatures and mitigate the heat island effect. The modern trend started when green roofs were developed in Germany in the 1960s, and has since spread to many countries. Today, it is estimated that about 10% of all German roofs have been “greened”. Green roofs are also becoming increasingly popular in the United States, although...

  5. The Self-Drying Concept for Flat Roofs

    DEFF Research Database (Denmark)

    Korsgaard, Vagn; Bunch-Nielsen, Tommy; Rode, Carsten

    1996-01-01

    Moisture in flat roof systems with an insulation layer has been a long-standing issue for the roof industry. It is now realised, that it is unrealistic and too costly to try to completely keep moisture from entering a roof assembly during its service life. The approach, therefore, should be to ke...... cold- and warm deck roof systems in climate zones where a vapor retarder is needed, if the traditional water proof vapor retarder is substituted by a water permeable vapor retarder....

  6. Local newforms and formal exterior square L-functions

    CERN Document Server

    Miyauchi, Michitaka

    2012-01-01

    Let F be a non-archimedean local field of characteristic zero. Jacquet and Shalika attached a family of zeta integrals to unitary irreducible generic representations $\\pi$ of GL_n(F). In this paper, we show that Jacquet-Shalika integral attains a certain L-function, so called the formal exterior square L-function, when the Whittaker function is associated to a newform for $\\pi$. By consideration on the Galois side, formal exterior square L-functions are equal to exterior square L-functions for some principal series representations.

  7. Spontaneously induced general relativity with holographic interior and general exterior

    CERN Document Server

    Shen, Xiao-Qing; Yang, Guo-Hong

    2012-01-01

    The general relativity (GR) might be viewed as a spontaneously induced theory from the scalar-tensor gravity, in which the would-have-been horizon connects the exterior solution of GR with a novel core of vanishing spatial volume. Using a simple but robust analytic method, we give the nontrivial core metric for the general exterior. Then we show that all the nontrivial features of the core, including the locally holographic entropy packing, are not influenced by the general exterior. We also investigate whether other modified theories of gravity can permit the nontrivial core.

  8. Study of Falling Roof Vibrations in a Production Face at Roof Support Resistance in the Form of Concentrated Force

    Science.gov (United States)

    Buyalich, G. D.; Buyalich, K. G.; Umrikhina, V. Yu

    2016-08-01

    One of the main reasons of roof support failures in production faces is mismatch of their parameters and parameters of dynamic impact on the metal structure from the falling roof during its secondary convergences. To assess the parameters of vibrational interaction of roof support with the roof, it was suggested to use computational models of forces application and a partial differential equation of fourth order describing this process, its numerical solution allowed to assess frequency, amplitude and speed of roof strata movement depending on physical and mechanical properties of the roof strata as well as on load bearing and geometry parameters of the roof support. To simplify solving of the differential equation, roof support response was taken as the concentrated force.

  9. 40 CFR 63.1042 - Standards-Separator fixed roof.

    Science.gov (United States)

    2010-07-01

    ...) National Emission Standards for Oil-Water Separators and Organic-Water Separators § 63.1042 Standards... controlling air emissions from an oil-water separator or organic-water separator using a fixed roof. (b) The... interface of the roof edge and the separator wall. (3) Each opening in the fixed roof shall be equipped...

  10. Recovery and reuse of asphalt roofing waste. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Desai, S.; Graziano, G.; Shepherd, P.

    1984-02-02

    Burning of asphalt roofing waste as a fuel and incorporating asphalt roofing waste in bituminous paving were identified as the two outstanding resource recovery concepts out of ten studied. Four additional concepts might be worth considering under different market or technical circumstances. Another four concepts were rated as worth no further consideration at this time. This study of the recovery of the resource represented in asphalt roofing waste has identified the sources and quantities of roofing waste. About six million cubic yards of scrap roofing are generated annually in the United States, about 94% from removal of old roofing at the job site and the remainder from roofing material production at factories. Waste disposal is a growing problem for manufacturers and contractors. Nearly all roofing waste is hauled to landfills at a considerable expense to roofing contractors and manufacturers. Recovery of the roofing waste resource should require only a modest economic incentive. The asphalt contained in roofing waste represents an energy resource of more than 7 x 10/sup 13/ Btu/year. Another 1 x 10/sup 13/ Btu/year may be contained in field-applied asphalt on commercial building roofs. The two concepts recommended by this study appear to offer the broadest applicability, the most favorable economics, and the highest potential for near-term implementation to reuse this resource.

  11. Green Roof Technology- Mitigate Urban Heat Island (UHI Effect

    Directory of Open Access Journals (Sweden)

    Odli Z.S. M.

    2016-01-01

    Full Text Available Alterations on the land surfaces, which are attributed by human activities, especially in cities, cause many implications to the ecosystem. The increase of buildings in cities is reflecting the growth of human activities resulted in a significant temperature increase and warmer pattern in the urban area than the surrounding countryside. The phenomenon defined as urban heat island. This study investigates the application and efficiency of the green roof as an approach to mitigate urban heat island and reducing indoor temperature in a building. Two types of roof models, which consist of vegetative roof and non-vegetative roof, were built to investigate the efficiency of vegetated roof in reducing indoor temperature compared to the non-vegetated roof. The outdoor and indoor temperature and humidity of each roof model were monitored by using RH520 Thermo Hygrometer. The data was collected for three times in a week for 9 weeks at 9:00am to 5:00pm. It was found that the indoor average temperature data for vegetative roof could be reduced 2.4°C from the outdoor average temperature and 0.8°C for non-vegetative roof. The difference of temperature reduction for vegetative roof was greater than the nonvegetative roof, thus indicate that green roof was highly efficient in reducing indoor temperature and mitigate urban heat island impact.

  12. Green roof establishment in extreme conditions : two case studies

    Energy Technology Data Exchange (ETDEWEB)

    Grothe, R. [Aloha Landscaping, Inc., Mendota Heights, MN (United States); Trichie, J. [Shakopee Mdewakanton Sioux Community, MN (United States)

    2007-07-01

    Green roof construction in the United States is growing at a rate of 60 to 80 per cent per year. This paper presented two case studies of green roof construction in Minnesota. In both cases, construction and budgeting delays moved the installation of the green roofs from early-May to mid-July. The first case study was a 20,000 square foot extensive green roof on the new Minneapolis Central Library which was completed in 2005. The second case study was a 30,000 square foot extensive green roof on the Mdewakanton Sioux Waste Water Treatment Plant in Shakopee, which was completed in 2006. This paper demonstrated that in order for green roofs to serve the functions for which they were intended, clear guidelines and specifications are needed to ensure that they are healthy. The size and locations of the two roofs were quite different, but they were identical in terms of waterproofing. State-of-the-art inverted hot-applied roof membrane technology was used in both roofs along with sub-surface irrigation systems. A mycorrhizae fungi was used in both cases to amend the growing medium. Both roofs used a diverse pallet of native and traditional sedum plant material. This paper highlighted preventative measures taken to ensure the successful installation and establishment of the two roofs built during extreme heat and drought-like conditions. The positive results confirm that it is possible to install green roofs during extremely harsh summer conditions. 9 refs., 4 tabs., 3 figs.

  13. 30 CFR 75.211 - Roof testing and scaling.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Roof testing and scaling. 75.211 Section 75.211 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Roof Support § 75.211 Roof testing and scaling. (a)...

  14. Causes of falls of roof in South African collieries

    CSIR Research Space (South Africa)

    Van der Merwe, JN

    2001-08-01

    Full Text Available on ta l s tre ss W ea th er ing Ba d m ini ng Dy ke s Bu rn t c oa l Contribution (% ) All Skin Large Major Figure 25. Causes of roof falls seen against the background of thickness of roof falls. 24 10 Influence of roof rock...

  15. Comercio exterior del sector porcino mexicano

    Directory of Open Access Journals (Sweden)

    Encarnación Ernesto Bobadilla-Soto

    2012-01-01

    Full Text Available El objetivo del presente trabajo fue analizar la dinámica del comercio exterior porcino mexicano, y el efecto de las importaciones de productos porcinos en el desplazamiento y sustitución de la producción en México. Para la dinámica se analizaron las tasas de crecimiento (decremento y las variaciones tanto en volumen y valor del subsector, de las fracciones arancelarias agrupadas en dos grandes rubros: a animales vivos y b carnes y despojos comestibles, que tienen un impacto directo en el desplazamiento y sustitución de la producción nacional. El desplazamiento y sustitución se calcularon con la suma de los valores de las importaciones, su relación con los pesos en canal de los animales durante los años analizados, y su equivalente en porcentaje a número de animales. El estudio comprende de 1990 a 2008. La balanza comercial al inicio del estudio fue de -180 mil toneladas equivalente a 1.4 millones de cerdos desplazados y al 13 % de la producción nacional. Para el 2008, la balanza comercial fue -581 mil toneladas, los cerdos desplazados se incrementaron a 5.9 millones equivalente al 39 % de la producción nacional.

  16. 40 CFR 65.45 - External floating roof converted into an internal floating roof.

    Science.gov (United States)

    2010-07-01

    ... AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Storage Vessels § 65.45... control storage vessel regulated material emissions by using an external floating roof converted into an...

  17. 30 CFR 75.204 - Roof bolting.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Roof bolting. 75.204 Section 75.204 Mineral... or the equivalent may be used. (3) Bearing plates used with wood or metal materials shall be at least... against wood; or (ii) Have exceeded the maximum specified torque or tension by 50 percent. (6) The...

  18. Accidents due to falls from roof slabs

    Directory of Open Access Journals (Sweden)

    Bruno Alves Rudelli

    Full Text Available CONTEXT AND OBJECTIVE Falls from the roof slabs of houses are accidents of high potential severity that occur in large Brazilian cities and often affect children and adolescents. The aims of this study were to characterize the factors that predispose towards this type of fall involving children and adolescents, quantify the severity of associated lesions and suggest preventive measures. DESIGN AND SETTING Descriptive observational prospective longitudinal study in two hospitals in the metropolitan region of São Paulo. METHODS Data were collected from 29 cases of falls from roof slabs involving children and adolescents between October 2008 and October 2009. RESULTS Cases involving males were more prevalent, accounting for 84%. The predominant age group was schoolchildren (7 to 12 years old; 44%. Leisure activities were most frequently being practiced on the roof slab at the time of the fall (86%, and flying a kite was the most prevalent game (37.9%. In 72% of the cases, the children were unaccompanied by an adult responsible for them. Severe conditions such as multiple trauma and traumatic brain injuries resulted from 79% of the accidents. CONCLUSION Falls from roof slabs are accidents of high potential severity, and preventive measures aimed towards informing parents and guardians about the dangers and risk factors associated with this type of accident are needed, along with physical protective measures, such as low walls around the slab and gates with locks to restrict free access to these places.

  19. One Roof Judicial System in Indonesia

    Directory of Open Access Journals (Sweden)

    - Sufiarina

    2012-09-01

    Full Text Available Judicial power as an independent and autonomous power must be free from any intervention and power, thus ensuring that judges possess independence and impartiality in handling cases. One of the measures for enhancing the independence and autonomy of the judiciary is by placing it under the one roof judicial arrangement developed by the Supreme Court, both from the judicial as well as the non-judicial technical aspects. Up to the present time, endeavors for bringing the four court jurisdictions under the one roof judicial arrangement developed by the Supreme Court have not been completely materialized, due to the existing dualism in judicial power at various courts. The objective of this research is to understand the developments in the endeavors towards bringing the Indonesian judicial system under the one roof judicial arrangement developed by the Supreme Court. The type of research applied is descriptive normative juridical research, namely legal research based on examining secondary data. As the research results indicate, the one roof system developed by the Supreme Court is already being implemented, with the exception of the Military Court and the Tax Court within the State Administration Court jurisdiction.

  20. Load-Bearing Capacity of Roof Trusses

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Damkilde, Lars; Munch-Andersen, J.

    2004-01-01

    systems such as roof trusses are established and statistical characteristics of the load bearing capacity are determined. The results show that there is a significant increase in the characteristic (nominal) value and a reduction in the coefficient of variation (COV) for typical loads such as permanent...

  1. Accidents due to falls from roof slabs.

    Science.gov (United States)

    Rudelli, Bruno Alves; Silva, Marcelo Valerio Alabarce da; Akkari, Miguel; Santili, Claudio

    2013-01-01

    CONTEXT AND OBJECTIVE Falls from the roof slabs of houses are accidents of high potential severity that occur in large Brazilian cities and often affect children and adolescents. The aims of this study were to characterize the factors that predispose towards this type of fall involving children and adolescents, quantify the severity of associated lesions and suggest preventive measures. DESIGN AND SETTING Descriptive observational prospective longitudinal study in two hospitals in the metropolitan region of São Paulo. METHODS Data were collected from 29 cases of falls from roof slabs involving children and adolescents between October 2008 and October 2009. RESULTS Cases involving males were more prevalent, accounting for 84%. The predominant age group was schoolchildren (7 to 12 years old; 44%). Leisure activities were most frequently being practiced on the roof slab at the time of the fall (86%), and flying a kite was the most prevalent game (37.9%). In 72% of the cases, the children were unaccompanied by an adult responsible for them. Severe conditions such as multiple trauma and traumatic brain injuries resulted from 79% of the accidents. CONCLUSION Falls from roof slabs are accidents of high potential severity, and preventive measures aimed towards informing parents and guardians about the dangers and risk factors associated with this type of accident are needed, along with physical protective measures, such as low walls around the slab and gates with locks to restrict free access to these places.

  2. Ballistic Missile Silo Door Monitoring Analysis

    Energy Technology Data Exchange (ETDEWEB)

    EDENBURN,MICHAEL W.; TROST,LAWRENCE C.

    2000-01-01

    This paper compares the cost and effectiveness of several potential options that may be used to monitor silo-based ballistic missiles. Silo door monitoring can be used to verify that warheads removed to deactivate or download silo-based ballistic missiles have not been replaced. A precedent for monitoring warhead replacement using reentry vehicle on site inspections (RV-OSIs) and using satellites has been established by START-I and START-II. However, other monitoring options have the potential to be less expensive and more effective. Three options are the most promising if high verification confidence is desired: random monitoring using door sensors; random monitoring using manned or unmanned aircraft; and continuous remote monitoring using unattended door sensors.

  3. WOODEN DOOR WINGS OF ADIYAMAN GREAT MOSQUE

    Directory of Open Access Journals (Sweden)

    Muhammet ARSLAN

    2010-06-01

    Full Text Available Woodworking which is in the most important Turk art branches have been used especially in Anatolia land readily. Wooden material that is seen on architectural units such as mimbar, ambo, wings of door and window, lectern has an important particularly with its ornamental figures. Wooden composition on the north and east doors of Adıyaman Great Mosque was built by Dulkadir Principality but regulated again in the last period of Ottoman Empire, is a theme which is exemined detailedly in Turk art. In this article, it is tried to determined ornamentel and tecnical characteristics of wooden door wings of Adıyaman Great Mosque belongs to early XX. century and the place of them in Turk art.

  4. Evolution of cool-roof standards in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Akbari, Hashem; Akbari, Hashem; Levinson, Ronnen

    2008-07-11

    Roofs that have high solar reflectance and high thermal emittance stay cool in the sun. A roof with lower thermal emittance but exceptionally high solar reflectance can also stay cool in the sun. Substituting a cool roof for a noncool roof decreases cooling-electricity use, cooling-power demand, and cooling-equipment capacity requirements, while slightly increasing heating-energy consumption. Cool roofs can also lower citywide ambient air temperature in summer, slowing ozone formation and increasing human comfort. Provisions for cool roofs in energy-efficiency standards can promote the building- and climate-appropriate use of cool roofing technologies. Cool-roof requirements are designed to reduce building energy use, while energy-neutral cool-roof credits permit the use of less energy-efficient components (e.g., larger windows) in a building that has energy-saving cool roofs. Both types of measures can reduce the life-cycle cost of a building (initial cost plus lifetime energy cost). Since 1999, several widely used building energy-efficiency standards, including ASHRAE 90.1, ASHRAE 90.2, the International Energy Conservation Code, and California's Title 24 have adopted cool-roof credits or requirements. This paper reviews the technical development of cool-roof provisions in the ASHRAE 90.1, ASHRAE 90.2, and California Title 24 standards, and discusses the treatment of cool roofs in other standards and energy-efficiency programs. The techniques used to develop the ASHRAE and Title 24 cool-roof provisions can be used as models to address cool roofs in building energy-efficiency standards worldwide.

  5. Notes on symmetric and exterior depth and annihilator numbers

    Directory of Open Access Journals (Sweden)

    Gesa Kampf

    2008-11-01

    Full Text Available We survey and compare invariants of modules over the polynomial ring and the exterior algebra. In our considerations, we focus on the depth. The exterior analogue of depth was first introduced by Aramova, Avramov and Herzog. We state similarities between the two notion of depth and exhibit their relation in the case of squarefree modules. Work of Conca, Herzog and Hibi and Trung, respectively, shows that annihilator numbers are a meaningful generalization of depth over the polynomial ring. We introduce and study annihilator numbers over the exterior algebra. Despite some minor differences in the definition, those invariants show common behavior. In both situations a positive linear combination of the annihilator numbers can be used to bound the symmetric and exterior graded Betti numbers, respectively, from above.

  6. Indices de valor unitario y quantum del comercio exterior colombiano

    National Research Council Canada - National Science Library

    Garavito, Aaron; Lopez, David; Montes, Enrique

    2014-01-01

    Los indices de valor unitario y quantum de las importaciones y exportaciones son una herramienta importante para el analisis del comportamiento del comercio exterior de un pais y su repercusion sobre...

  7. Fire hazards of exterior wall assemblies containing combustible components

    Directory of Open Access Journals (Sweden)

    White Nathan

    2013-11-01

    Full Text Available The Fire Protection Research Foundation has funded a research project on “fire hazards of exterior wall assemblies containing combustible composites”. This paper presents preliminary findings from the project. In particular, statistics relating to exterior wall fires have been reviewed. Exterior wall fires appear to account for somewhere between 1.3% and 3% of structure fires in the selected property types investigated. Fires involving combustible exterior wall assemblies are low frequency events however the resulting consequences in terms of extent of fire spread and injuries and fatalities can be large as demonstrated by selected fire incident case studies. An overview of this project and it's further work is provided.

  8. Ecological Impacts of Replacing Traditional Roofs with Green Roofs in Two Urban Areas

    Directory of Open Access Journals (Sweden)

    Timothy Carter

    2008-01-01

    Full Text Available Urban land cover is dominated by impervious surface that degrades both terrestrial and aquatic ecosystems relative to predevelopment conditions. There are significant opportunities for designers of urban landscapes to use alternative land covers that have multiple functions, benefiting both human and nonhuman components of the urban ecosystem. Vegetated (green roofs are one form of alternative land cover that has shown the potential to provide a variety of ecological benefits in urban areas. We evaluated how stormwater retention, building energy and temperature, and rooftop habitat are influenced by the use of green roofs using test plots in Georgia and Massachusetts. Green roofs were shown to recreate part of the predevelopment hydrology through increasing interception, stormwater storage, evaporation, and transpiration on the rooftop and worked extremely well for small storm events. Temperature reductions were found on the green rooftop as compared to an asphalt surface, although other roof technologies that minimize temperatures, such as lighter colored membranes, provide similar benefits. Novel habitat was created on the rooftop, although the extent of this habitat was limited in part by plant survivability and the need for additional water inputs for diverse plant communities to survive. Despite the challenges, the green roof benefits reported here suggest that green roofs can be used effectively as a multifunctional land cover in urban areas.

  9. Semantic 3D Modeling Based on CityGML for Ancient Chinese-Style Architectural Roofs of Digital Heritage

    Directory of Open Access Journals (Sweden)

    Lin Li

    2017-04-01

    Full Text Available Ancient Chinese-style architecture has received increased attention during the last century as a segment of cultural heritage and is of great significance, specifically in regard to the process of digitizing and modeling these buildings to preserve and protect this heritage. Because the roof form reflects the age of the structure, the structural character and the historical culture of the ancient building, constructing a refined model for the roof is a primary aspect of the 3D modeling procedure. To avoid cumbersome traditional modeling approaches that use geometry units, such as points, lines and triangles, a flexible semantic method is proposed in this study to improve modeling efficiency and reduce the professional requirements. In this method, a two-level semantic decomposition of the roof is presented according to the characteristics of ancient Chinese-style architecture. The structural level reveals the basic components that determine its structural shape, and the decorative level refers to the attached components that influence the exterior appearance. The assembly validity of the decomposed elements and the combined diversity of the integrated entities are ensured by topological constraints and derived transformations of the semantic components. This proposed method was implemented by utilizing CityGML (City Geography Markup Language via the ADE (Application Domain Extension mechanism and was tested by modeling the principal buildings included in the Palace Museum.

  10. Status of cool roof standards in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Akbari, Hashem; Levinson, Ronnen

    2007-06-01

    Since 1999, several widely used building energy efficiency standards, including ASHRAE 90.1, ASHRAE 90.2, the International Energy Conservation Code, and California's Title 24 have adopted cool roof credits or requirements. We review the technical development of cool roof provisions in the ASHRAE 90.1, ASHRAE 90.2, and California Title 24 standards, and discuss the treatment of cool roofs in other standards and energy-efficiency programs. The techniques used to develop the ASHRAE and Title 24 cool roof provisions can be used as models to address cool roofs in building energy standards worldwide.

  11. Green roofs as a means of pollution abatement.

    Science.gov (United States)

    Rowe, D Bradley

    2011-01-01

    Green roofs involve growing vegetation on rooftops and are one tool that can help mitigate the negative effects of pollution. This review encompasses published research to date on how green roofs can help mitigate pollution, how green roof materials influence the magnitude of these benefits, and suggests future research directions. The discussion concentrates on how green roofs influence air pollution, carbon dioxide emissions, carbon sequestration, longevity of roofing membranes that result in fewer roofing materials in landfills, water quality of stormwater runoff, and noise pollution. Suggestions for future directions for research include plant selection, development of improved growing substrates, urban rooftop agriculture, water quality of runoff, supplemental irrigation, the use of grey water, air pollution, carbon sequestration, effects on human health, combining green roofs with complementary related technologies, and economics and policy issues.

  12. STUDIES ON THE LAW OF ROOF-COAL MOVEMENT BY USING THE ROOF-COAL CAVING METHOD

    Institute of Scientific and Technical Information of China (English)

    张海戈; 徐秉业; 沈新普; 王志勤

    1996-01-01

    In this paper, the law of roof-coal movement has been investigated through the fieldmeasurement, theoretical analysis and numerical calculation. Several results, which are of im-portant values for caving process, design of the supports, controlling end-face stability, raisingrecovery rate, realizing working face high output and other related aspects in practice, havebeen obtained. These results mainly include the following: roof-coal breaking curve of soft-coalseam, roof-coal movement curve of soft-coal and medium-hard coal seam, and roof-coal move-ment equation. The roof-coal caveability has been analyzed.

  13. Establishing green roof infrastructure through environmental policy instruments.

    Science.gov (United States)

    Carter, Timothy; Fowler, Laurie

    2008-07-01

    Traditional construction practices provide little opportunity for environmental remediation to occur in urban areas. As concerns for environmental improvement in urban areas become more prevalent, innovative practices which create ecosystem services and ecologically functional land cover in cities will be in higher demand. Green roofs are a prime example of one of these practices. The past decade has seen the North American green roof industry rapidly expand through international green roof conferences, demonstration sites, case studies, and scientific research. This study evaluates existing international and North American green roof policies at the federal, municipal, and community levels. Green roof policies fall into a number of general categories, including direct and indirect regulation, direct and indirect financial incentives, and funding of demonstration or research projects. Advantages and disadvantages of each category are discussed. Salient features and a list of prompting standards common to successfully implemented green roof strategies are then distilled from these existing policies. By combining these features with data collected from an experimental green roof site in Athens, Georgia, the planning and regulatory framework for widespread green roof infrastructure can be developed. The authors propose policy instruments be multi-faceted and spatially focused, and also propose the following recommendations: (1) Identification of green roof overlay zones with specifications for green roofs built in these zones. This spatial analysis is important for prioritizing areas of the jurisdiction where green roofs will most efficiently function; (2) Offer financial incentives in the form of density credits and stormwater utility fee credits to help overcome the barriers to entry of the new technology; (3) Construct demonstration projects and institutionalize a commitment greening roofs on publicly-owned buildings as an effective way of establishing an educated

  14. Establishing Green Roof Infrastructure Through Environmental Policy Instruments

    Science.gov (United States)

    Carter, Timothy; Fowler, Laurie

    2008-07-01

    Traditional construction practices provide little opportunity for environmental remediation to occur in urban areas. As concerns for environmental improvement in urban areas become more prevalent, innovative practices which create ecosystem services and ecologically functional land cover in cities will be in higher demand. Green roofs are a prime example of one of these practices. The past decade has seen the North American green roof industry rapidly expand through international green roof conferences, demonstration sites, case studies, and scientific research. This study evaluates existing international and North American green roof policies at the federal, municipal, and community levels. Green roof policies fall into a number of general categories, including direct and indirect regulation, direct and indirect financial incentives, and funding of demonstration or research projects. Advantages and disadvantages of each category are discussed. Salient features and a list of prompting standards common to successfully implemented green roof strategies are then distilled from these existing policies. By combining these features with data collected from an experimental green roof site in Athens, Georgia, the planning and regulatory framework for widespread green roof infrastructure can be developed. The authors propose policy instruments be multi-faceted and spatially focused, and also propose the following recommendations: (1) Identification of green roof overlay zones with specifications for green roofs built in these zones. This spatial analysis is important for prioritizing areas of the jurisdiction where green roofs will most efficiently function; (2) Offer financial incentives in the form of density credits and stormwater utility fee credits to help overcome the barriers to entry of the new technology; (3) Construct demonstration projects and institutionalize a commitment greening roofs on publicly-owned buildings as an effective way of establishing an educated

  15. Maillard-reactie door model beheersbaar

    NARCIS (Netherlands)

    Roost, van M.

    2006-01-01

    Gewenste en ongewenste bruinkleuring van levensmiddelen door een Maillard-reactie is vaak lastig te beheersen. Wageningse onderzoekers ontwikkelden een simulatiemodel, waarmee producentenmeer inzicht krijgen in de Maillard-reactie, en zo ook de kleur van het eindproduct beter kunnen beheersen tijden

  16. Opnieuw sterfte van jonge bomen door woelmuizen

    NARCIS (Netherlands)

    Moraal, L.G.

    2002-01-01

    In het begin van de jaren negentig trad er behoorlijk veel schade op bij bosaanleg in het kader van de Randstadgroenstructuur en de set-aside regelingen in Groningen en Drenthe. De boompjes waren geplant op voormalige landbouwgrond. Door snelle verruiging van de vegetatie, ontstaat er voor woelmuize

  17. Schade door overstroming: Ervaringen uit New Orleans

    NARCIS (Netherlands)

    Kok, M.; Theunissen, R.; Jonkman, S.N.; Vrijling, J.K.

    2006-01-01

    Korte samenvatting van de overstromingen door hurricane Katrina in augustus 2005 in New Orleans en omgeving. Beschrijving van de effecten op het gebied en de bewoners, kwantitatieve inschatting van de gevolgend, en wat we hieruit voor Nederland kunnen leren. Uitgave met ondersteuning van het

  18. Zuivel en soep gezonder door logo

    NARCIS (Netherlands)

    Temme, E.H.M.

    2008-01-01

    Gezondheidslogo’s verspreiden zich door de schappen van de supermarkt. Het blauwe vinkje van de stichting Ik kies bewust en het klavertje vier van supermarkt Albert Heijn moeten zorgen voor een gezonder aanbod van voedingsmiddelen. Liesbeth Temme van RIKILT – Instituut voor voedselveiligheid onderzo

  19. Verspreiding van komkommerbontvirus (CGMMV) door vogels

    NARCIS (Netherlands)

    Stijger, I.; Hamelink, R.; Ludeking, D.J.W.

    2012-01-01

    Het komkommerbontvirus is een zeer persistent virus. De afgelopen jaren heeft het zich uitgebreid naar meerdere bedrijven. Door komkommertelers worden veel verschillende maatregelen op het gebied van hygiëne doorgevoerd om het virus uit de kas te houden of om verspreiding te voorkomen. Ondanks deze

  20. Pixel masks for screen-door transparency

    NARCIS (Netherlands)

    Mulder, J.D.; Groen, F.C.A.; Wijk, J.J. van

    1998-01-01

    Rendering objects transparently gives additional insight in complex and overlapping structures. However, traditional techniques for the rendering of transparent objects such as alpha blending are not very well suited for the rendering of multiple transparent objects in dynamic scenes. Screen-door tr

  1. Door grond horizontaal belaste palen: Bestaande ontwerpmodellen

    NARCIS (Netherlands)

    Hoefsloot, F.J.M.

    2008-01-01

    In het algemeen is een door grond horizontaal belaste paal een 3-D situatie, die in 1 fase direct met een 3-D EEM-model (zoals PLAXIS 3D Foundation) kan worden gemodelleerd. Deze modellen zijn echter gecompliceerd en pas de laatste jaren eenvoudiger toepasbaar in de adviespraktijk. Een directe berek

  2. Salazarismo y política exterior

    Directory of Open Access Journals (Sweden)

    Juan Carlos JIMÉNEZ REDONDO

    2010-02-01

    Full Text Available RESUMEN: El sistema internacional jugó para la Portugal de Salazar un papel esencial al actuar como fuente privilegiada de la que extraer los recursos materiales (económicos, tecnológicos o financieros e inmateriales (factores de legitimación que garantizaron el programa de reforma política de la dictadura y que permitieron al país desempeñar un papel internacional desproporcionadamente relevante si consideramos su condición de pequeña potencia periférica europea. La novedad del salazarismo respecto a períodos anteriores consistió en la adecuación de esas necesidades de apertura al exterior con una fuerte percepción de los intereses nacionales, dentro de una estrategia pragmática que le permitió acomodarse a la acelerada evolución del sistema internacional y, sobre todo, al cambio que se produjo en el sistema internacional de acuerdo a la dinámica de la Guerra Fría y sus distintas fases. Palabras clave: Salazarismo, OTAN, EFTA, Botelho Moniz, Guerra colonial, descolonización. ABSTRACT: The international system played for the Portugal of Salazar an essential role when acting like privileged source of which to extract the material resources (economic, technological or financial and immaterial (legitimation factors that guaranteed the program of political reform of the dictatorship and that allowed the country to play very out of proportion excellent a role international if we considered its condition of small European peripheral power. The newness of the salazarism with respect to previous periods consisted of the adjustment of those necessities of opening to the outside with a strong perception of the national interests, within a pragmatic strategy that allowed to comply him to the accelerated evolution of the international system and, mainly, to the change that took place in the international system according to the dynamics of the cold war and its different phases. Keywords: Salazarism, NATO, EFTA, Botelho Moniz, Colonial

  3. From "Closing Doors" to "Opening Doors": Exploring gender and subject choice in UK schools

    Science.gov (United States)

    Marks, Ann

    2015-12-01

    Two reports drawing on the National (English) Pupil Database are discussed: the It's Different for Girls and the Closing Doors reports (2012 and 2013, respectively), both of which examine the experience of girls studying physics in England. The UK government has responded to these studies by launching the "Opening Doors" project (June 2014), which will focus on a whole-school approach to addressing gender imbalance in progression to post-16 studies.

  4. Accuracy of the blower door measurement; Genauigkeit der Blower Door-Messung. Der Einfluss von Aussenklimaparametern

    Energy Technology Data Exchange (ETDEWEB)

    Weier, H. [Hochschule fuer Technik, Wirtschaft und Sozialwesen Zittau/Goerlitz (FH), Zittau (Germany)

    2000-04-01

    The blower door is a simple to use measuring device for determing the seal of the external surfaces of buildings. The accuracy of the measurement is dependent to a considerable extent on the external climatic conditions that prevail at the time of taking the measurement. (orig.) [German] Die Blower Door ist ein einfach anzuwendendes Messgeraet zum Bestimmen der Dichtheit von Gebaeudeaussenflaechen. Die Genauigkeit der Messung ist in starkem Masse von den zum Messzeitpunkt herrschenden Aussenklimabedingungen abhaengig. (orig.)

  5. 46 CFR 32.56-35 - Doors-T/ALL.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Doors-T/ALL. 32.56-35 Section 32.56-35 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS SPECIAL EQUIPMENT, MACHINERY, AND HULL REQUIREMENTS... Doors—T/ALL. (a) Casing doors in category A machinery spaces and all elevator doors must be self-closing...

  6. Automated exterior inspection of an aircraft with a pan-tilt-zoom camera mounted on a mobile robot

    Science.gov (United States)

    Jovančević, Igor; Larnier, Stanislas; Orteu, Jean-José; Sentenac, Thierry

    2015-11-01

    This paper deals with an automated preflight aircraft inspection using a pan-tilt-zoom camera mounted on a mobile robot moving autonomously around the aircraft. The general topic is image processing framework for detection and exterior inspection of different types of items, such as closed or unlatched door, mechanical defect on the engine, the integrity of the empennage, or damage caused by impacts or cracks. The detection step allows to focus on the regions of interest and point the camera toward the item to be checked. It is based on the detection of regular shapes, such as rounded corner rectangles, circles, and ellipses. The inspection task relies on clues, such as uniformity of isolated image regions, convexity of segmented shapes, and periodicity of the image intensity signal. The approach is applied to the inspection of four items of Airbus A320: oxygen bay handle, air-inlet vent, static ports, and fan blades. The results are promising and demonstrate the feasibility of an automated exterior inspection.

  7. Blower door measurements - extended measuring methods; Blower Door-Messungen - erweiterte Messmethoden

    Energy Technology Data Exchange (ETDEWEB)

    Geissler, A.; Bolender, T.; Hauser, G. [Kassel Univ. (Germany). Fachgebiet Bauphysik

    1997-05-01

    To determine the air tightness of the external envelope, blower door measurements are normally carried out. The thus determined integral figure for the complete structure is an insufficient basis for carrying out specific insulation procedures in existing buildings. Within the scope of the air tightness measurements with the blower door, additional measuring methods permit the determination of additional information on the leakage distribution and the leakage routes. The expanded measuring methods that are known from the bibliography `opening a door` and `adding a hole` as well as the new method of `adding a hole plus` are explained, compared by means of exemplary measurements, and are considered for their suitability during field trials. (orig.) [Deutsch] Zur Bestimmung der Luftdichtheit der Gebaeudehuelle werden im allgemeinen Blower Door-Messungen durchgefuehrt. Der hierbei bestimmte integrale Wert fuer das gesamte Gebaeude stellt fuer das Ergreifen von gezielten Abdichtungsmassnahmen im Gebaeudebestand eine zu geringe Basis dar. Weiterfuehrende Messmethoden erlauben, im Rahmen von Luftdichtheitsmessungen mit der Blower Door zusaetzliche Informationen ueber die Leckageverteilung und ueber Leckagewege zu bestimmen. Die aus der Literatur bekannten erweiterten Messmethoden `Opening A Door` und `Adding A Hole` sowie die neue Methode `Adding A Hole Plus` werden erlaeutert, anhand von exemplarischen Messungen verglichen und im Feldeinsatz auf ihre Anwendbarkeit hin betrachtet. (orig.)

  8. Improving the durability of flat roof constructions

    DEFF Research Database (Denmark)

    Rudbeck, Claus Christian; Svendsen, Sv Aa Højgaard

    1999-01-01

    Flat roof constructions are mainly used on commercial, institutional and industrial buildings, where insulation is placed on top of the load-bearing deck and then covered with a roof membrane. Through time, there is a risk that the membrane will allow water passage as holes might form due...... to weathering effects or physical loads. Water will then enter the insulation, and as a vapor retarder is normally found below the insulation thus trapping the water in the insulation, the leak can remain undetected for a long period. When the leak is finally discovered, the insulation has to be discharged...... of the system, thereby making it easier to detect leaks faster. When a leak is detected, the membrane is repaired locally. In order to remove water which has already entered the insulation, an air gap or a system of air channels between the deck and the insulation is subjected to forced ventilation with outdoor...

  9. PERFORMANCE OF AN EARTHQUAKE EXCITED ROOF DIAPHRAGM.

    Science.gov (United States)

    Celebi, M.; Brady, G.; Safak, E.; Converse, A.; ,

    1986-01-01

    The objective of this paper is to study the earthquake performance of the roof diaphragm of the West Valley College gymnasium in Saratoga, California through a complete set of acceleration records obtained during the 24 April 1984 Morgan Hill Earthquake (M equals 6. 1). The roof diaphragm of the 112 ft. multiplied by 144 ft. rectangular, symmetric gymnasium consists of 3/8 in. plywood over tongue-and-groove sheathing attached to steel trusses supported by reinforced concrete columns and walls. Three sensors placed in the direction of each of the axes of the diaphragm facilitate the evaluation of in-plane deformation of the diaphragm. Other sensors placed at ground level measure vertical and horizontal motion of the building floor, and consequently allow the calculation of the relative motion of the diaphragm with respect to the ground level.

  10. Lightning Protection of Floating Roof Tanks

    Directory of Open Access Journals (Sweden)

    Adekitan,

    2013-10-01

    Full Text Available Prior to export, processed crude oil is stored in Floating Roof Tanks (FRT to further allow any trapped gas within the crude oil to escape, as this stabilises the crude oil. In the oil and gas industry, FRT’s are vital in the processing of crude oil to the acceptable export specification.In the tropics and other lightning prone regions, lightning induced floating roof tank fire constitutes a major threat to crude oil production. Among others, a single lightning incident could result in the loss of life, product and production time, avoidable incident review time, damaged equipment, wasted repair cost, bad publicity and loss of income.This paper therefore, is aimed at providing an effective solution to the menace of lightning induced tank fire by focussing on the starting process of the lightning induced fire and proposing alternative concepts for breaking the fire triangle before fire ensues

  11. Creating a marketplace for green roofs in Chicago

    Energy Technology Data Exchange (ETDEWEB)

    Vitt Sale, L. [Wright and Co. Chicago, IL (United States); Berkshire, M. [City of Chicago, IL (United States)

    2004-07-01

    Since 2003, the Chicago Department of Planning and Development has been encouraging city developers to consider installing green roofs on buildings in Chicago, with the belief that this practice results in mitigation of the urban heat island effect, cleaner runoff leaving green roofs, sound attenuation, aesthetic value, oxygen production, and mitigation of carbon dioxide emissions. However, the benefits to developers, which include reduced stormwater runoff, extended roof life and energy savings, in total do not offset the first cost premium of a green roof. Despite this, and with no mandate requiring green roofs, the marketplace is growing. After seeing green roofs on a tour in Europe, the mayor of Chicago encouraged the first design and installation of a 20,300 square foot demonstration green roof in Chicago, and other city-sponsored pilot projects followed shortly after. Since then, the number of green roofs in Chicago has grown to over one million square feet. A map of Chicago showing locations of most of the projects was presented. It was suggested that lower prices for green roofs, higher energy costs and an inclination to invest in long-term strategies would accelerate the market. In an effort to engage the public in dialogue, the Department of Planning and Development held seminars to promote the benefits of green roofs . Participants had many questions about the applicability of green roofs to Chicago, expressing skepticism that Chicago's climate would provide the same benefits as in Europe. Other concerns were expressed regarding the devaluation of property values resulting from placing green roofs on buildings; doubts about roof leaks; maintenance practices; and, bugs and mold. Since the first cost premium of the system remains a question, most participants expressed interest in some kind of incentive program, but remained open-minded if benefits could be proved. 6 figs.

  12. Installation of a Roof Mounted Photovoltaic System

    Science.gov (United States)

    Lam, M.

    2015-12-01

    In order to create a safe and comfortable environment for students to learn, a lot of electricity, which is generated from coal fired power plants, is used. Therefore, ISF Academy, a school in Hong Kong with approximately 1,500 students, will be installing a rooftop photovoltaic (PV) system with 302 solar panels. Not only will these panels be used to power a classroom, they will also serve as an educational opportunity for students to learn about the importance of renewable energy technology and its uses. There were four different options for the installation of the solar panels, and the final choice was made based on the loading capacity of the roof, considering the fact that overstressing the roof could prove to be a safety hazard. Moreover, due to consideration of the risk of typhoons in Hong Kong, the solar panel PV system will include concrete plinths as counterweights - but not so much that the roof would be severely overstressed. During and after the installation of the PV system, students involved would be able to do multiple calculations, such as determining the reduction of the school's carbon footprint. This can allow students to learn about the impact renewable energy can have on the environment. Another project students can participate in includes measuring the efficiency of the solar panels and how much power can be produced per year, which in turn can help with calculate the amount of money saved per year and when we will achieve economic parity. In short, the installation of the roof mounted PV system will not only be able to help save money for the school but also provide learning opportunities for students studying at the ISF Academy.

  13. Experimental Polyurethane Foam Roof Systems - II.

    Science.gov (United States)

    1983-01-01

    reflect the effects of cloud cover, windspeed, and radiation from the roof during early morning and late evening hours. Measurement of the area under the...INN \\k I, N’. tlir’I’iii V A I \\’A SIurelS42r. K110i tlIe. I ct Ili Solair i imip .\\r nill. Kiw\\\\, tMe. I N I C(I’ 0)1,4 (IC, Ni’rtolk. \\.A ( ( I

  14. Roof timber for fortifying mining works

    Energy Technology Data Exchange (ETDEWEB)

    Shirokov, A.P.; Kuntsevich, V.IK.; Pishchulin, V.V.; Seryi, A.M.; Volkov, P.A.

    1981-05-15

    The roof timber for fortifying mining works includes spring-mounted hinged elements made from a special rolled metal. In order to increase the carrying capacity of the support by increasing the deformation threshold, the springs are mounted by their expanded section to the lower side of the hinge; their ends are connected in turn to the elements made from the special rolled metal on both sides of the hinge.

  15. EXTRUDED POLYSTYRENE FOAM IN FLAT ROOFS

    Directory of Open Access Journals (Sweden)

    Zhukov Aleksey Dmitrievich

    2014-09-01

    Full Text Available In our article we prove the necessity of applying thermal insulation with low water absorption and resistance and preserving mechanical and thermophysical properties in corrosive environment in flat roofs, where there is always a danger of penetrating condensed moisture into the structure. As such material we offered extruded polystyrene foam - heat-insulating polymer material with uniformly distributed closed cells. The products are used in the form of slab insulation and special items - for forming slopes and venting.

  16. Control of roofs difficult to break down

    Energy Technology Data Exchange (ETDEWEB)

    Lukashov, V.G.; Suslyakov, V.P.; Korobov, A.N.

    1981-03-01

    This paper describes a method of advanced torpedoing a roof difficult to break down at the Polysaevskaya coal mine. It consists in placing explosive charges in the roof ahead of the coal face. Three schemes were tested: boreholes were drilled parallel to the face, perpendicular or inclined at an angle to the face. Boreholes were 112 mm in diameter and their length ranged from 30 to 100 m, distance between the boreholes amounted to 20 m. 6ZhV ammonite explosive, 90 mm in diameter and 500 mm long, were used. Torpedos were 2 m long, and separated by 3 to 4 m long air pockets. When a roof characterized by a high compressive strength coefficient (about 10 on the Protod'yakonov scale) was torpedoed, 250 kg of ammonite were used for a borehole 80 m long, and 160 kg for a borehole 50 m long. When borehole length was reduced to 40 m explosive consumption decreased to 117 kg. In the case of rocks with compressive strength coefficient of 6, explosive amount was two times lower. In a coal mine in which an OKP-70 face system was used applying advanced torpedoing increased labor productivity of the face by 30% and reduced cost of mining by 42%. Number of work accidents was reduced 13 times. (In Russian)

  17. Seismic strengthening of RC structures with exterior shear walls

    Indian Academy of Sciences (India)

    Hasan Kaplan; Salih Yilmaz; Nihat Cetinkaya; Ergin Atimtay

    2011-02-01

    Vulnerable buildings and their rehabilitation are important problems for earthquake regions. In recent decades the goal of building rehabilitation and strengthening has gained research attention and numerous techniques have been developed to achieve this. However, most of these strengthening techniques disturb the occupants, who must vacate the building during renovation. In this study, a new strengthening alternative for RC structures, namely exterior shear walls, has been experimentally investigated under reversed cyclic loading. Using the proposed technique, it is possible to strengthen structures without disturbing their users or vacating the building during renovation. In this technique, shear walls are installed in parallel to the building’s exterior sides. It has been observed that the usage of exterior shear walls considerably improve the capacity and sway stiffness of RC structures. The experimental results have also been compared and found to be in agreement with the numerical solutions. Post attached exterior shear walls behaved as a monolithic member of the structure. Design considerations for the exterior shear wall-strengthened buildings have also been discussed in the paper.

  18. The Radially Symmetric Euler Equations as an Exterior Differential System

    Science.gov (United States)

    Baty, Roy; Ramsey, Scott; Schmidt, Joseph

    2016-11-01

    This work develops the Euler equations as an exterior differential system in radially symmetric coordinates. The Euler equations are studied for unsteady, compressible, inviscid fluids in one-dimensional, converging flow fields with a general equation of state. The basic geometrical constructions (for example, the differential forms, tangent planes, jet space, and differential ideal) used to define and analyze differential equations as systems of exterior forms are reviewed and discussed for converging flows. Application of the Frobenius theorem to the question of the existence of solutions to radially symmetric converging flows is also reviewed and discussed. The exterior differential system is further applied to derive and analyze the general family of characteristic vector fields associated with the one-dimensional inviscid flow equations.

  19. NC green roof stormwater quantity and quality field evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Moran, A.; Hunt, B.; Jennings, G. [North Carolina State Univ., Raleigh, NC (United States). Dept. of Biological and Agricultural Engineering

    2004-07-01

    A study was conducted in an effort to establish design standards for green roofs in North Carolina (NC). It was conducted in light of recent regulations that require stormwater runoff to be treated by structural controls in urban development. Two extensive green roofs were constructed within the Neuse River Basin in order to estimate the per cent of precipitation retained by the green roof; estimate the per cent peak flow reduction; determine whether green roofs can be used as nutrient reduction best management practices (BMPs) and if so, what removal efficiency should be assigned to green roofs; identify green roof vegetation types that thrive in central and eastern NC and find an optimal depth of soil for desirable plant growth. The determining factors for greater water retention were found to be soil depth and plant selection. BMPs such as bioretention areas, wet and dry detention ponds, constructed wetlands, and sand filters are commonly seen throughout NC. A new option for BMPs is the green roof to use thousands of square feet available on rooftops that would not otherwise be available on the ground. Each green roof in this study retained about 60 per cent of the total recorded rainfall during a nine-month observation period. The average peak flow reduction for both green roofs was about 85 per cent. Water quality data indicated that higher concentrations of total nitrogen and total phosphorous were present in the green roof runoff than in the control roof runoff and in the rainfall at each green roof site. This may be a result of N and P leaching from the soil media, which was composed of 15 per cent compost. It was suggested that leaching could be reduced with less organic matter present in the soil media. 12 refs., 1 tab., 8 figs.

  20. Research on hydraulic-powered roof supports test problems

    Institute of Scientific and Technical Information of China (English)

    SUN Hong-bo; JIANG Jin-qiu; MA Qiang

    2011-01-01

    The load-bearing characters of hydraulic-powered roof support with dual telescopic legs were analyzed. With a specific type hydraulic-powered roof support with dual telescopic legs for research object, the inside load test problems in factories was analyzed, and the correct test methods were given, which can enhance the test efficiency and make the factories away from the error design of hydraulic-powered roof supports and legs.

  1. Reviewing Green roof design approaches: Case study of residential buildings

    OpenAIRE

    Özarısoy, Bertuğ

    2013-01-01

    ABSTRACT: High density of the residential areas and steep land value in the cities have driven people to maximize liveable and productive spaces in urban settings. This includes the reinvention of roof functions extending merely as a protection from the elements to a platform of housing green building technologies such as green roofs. Increased interest in green roofs have led to advances in technology. An entire industry has sprung up which specializes in lightweight growing materials, ro...

  2. [Spatial orientation of pilot using a cockpit exterior surveillance system].

    Science.gov (United States)

    Chuntul, A V; Lapa, V V; Davydov, V V

    2013-01-01

    Spatial orientation of pilots using a cockpit exterior surveillance system was tested in real nighttime helicopter flights. Major factors complicating adequate spatial orientation and provoking visual illusions in pilots are lack of information for spatial depth (relation) perception in two-dimensional TV images altering their position along the horizontal and vertical lines of trajectory and simultaneous piloting and target search-identification operations. Reliability of pilot's spatial orientation could be improved by displaying on the exterior imaging screen also relevant flight navigation parameters.

  3. Deformed exterior algebra, quons and their coherent states

    CERN Document Server

    El-Baz, M

    2002-01-01

    We review the notion of the deformation of the exterior wedge product. This allows us to construct the deformation of the algebra of exterior forms over a vector space and also over an arbitrary manifold. We relate this approach to the generalized statistics and we study quons, as a particular case of these generalized statistics. We also give their statistical properties. A large part of the work is devoted to the problem of constructing coherent states for the deformed oscillators. We give a review of all the approaches existing in the literature concerning this point and enforce it with many examples.

  4. Numerical conformal mapping methods for exterior and doubly connected regions

    Energy Technology Data Exchange (ETDEWEB)

    DeLillo, T.K. [Wichita State Univ., KS (United States); Pfaltzgraff, J.A. [Univ. of North Carolina, Chapel Hill, NC (United States)

    1996-12-31

    Methods are presented and analyzed for approximating the conformal map from the exterior of the disk to the exterior a smooth, simple closed curve and from an annulus to a bounded, doubly connected region with smooth boundaries. The methods are Newton-like methods for computing the boundary correspondences and conformal moduli similar to Fornberg`s method for the interior of the disk. We show that the linear systems are discretizations of the identity plus a compact operator and, hence, that the conjugate gradient method converges superlinearly.

  5. Storm Water Retention on Three Green Roofs with Distinct Climates

    Science.gov (United States)

    Breach, P. A.; Sims, A.; O'Carroll, D. M.; Robinson, C. E.; Smart, C. C.; Powers, B. S. C.

    2014-12-01

    As urbanization continues to increase the impact of cities on their surrounding environments, the feasibility of implementing low-impact development such as green roofs is of increasing interest. Green roofs retain and attenuate storm water thereby reducing the load on urban sewer systems. In addition, green roofs can provide insulation and lower roof surface temperature leading to a decrease in building energy load. Green roof technology in North American urban environments remains underused, in part due to a lack of climate appropriate green roof design guidelines. The capacity of a green roof to moderate runoff depends on the storage capacity of the growing medium at the start of a rainfall event. Storage capacity is finite, which makes rapid drainage and evapotranspiration loss critical for maximizing storage capacity between subsequent storms. Here the retention and attenuation of storm events are quantified for experimental green roof sites located in three representative Canadian climates corresponding to; semiarid conditions in Calgary, Alberta, moderate conditions in London, Ontario, and cool and humid conditions in Halifax, Nova Scotia. The storage recovery and storm water retention at each site is modelled using a modified water balance approach. Components of the water balance including evapotranspiration are predicted using climate data collected from 2012 to 2014 at each of the experimental sites. During the measurement period there were over 300 precipitation events ranging from small, frequent events (green roofs in their respective climates.

  6. Can green roofs provide habitat for urban bees (Hymenoptera: Apidae?

    Directory of Open Access Journals (Sweden)

    Laurence Packer

    2009-01-01

    Full Text Available Increasing urbanization of many regions of the world has resulted in the decline of suitable habitat for wild flora and fauna. Green roofs have been suggested as a potential avenue to provide patches of good-quality habitat in highly developed regions. In this study, we surveyed green roofs for bee diversity and abundance to determine their potential as quality habitats in an urban area for these important pollinators. By comparing various biodiversity measures between green roofs and ground-level sites, we show that green roofs provide habitat to many bee species. Implications for pollinator conservation and urban agricultural production are discussed.

  7. Green roofs in Germany : yesterday, today and tomorrow

    Energy Technology Data Exchange (ETDEWEB)

    Herman, R. [Anhalt Univ., Bernburg (Germany)

    2003-07-01

    This presentation provided a historical overview of the development of green roofs in Germany. Real interest in green roof technology in Germany began in the 1970s at which time specific guidelines for correct installation were established. In the past 20 years there has been a dramatic increase in the number of green roofs. The main market drivers were ecological concerns, energy and cost saving potential, as well as the need to manage storm water. Green roofs have an insulating effect, leading to energy savings. Some cities in Germany have implemented an incentive program whereby reductions on city water fees are allocated to owners of green roofs. Many business opportunities have been created by an increased interest in green roofs. The demand for lava, pumice, expanded clay, recycled roof tiles, crushed brick and other materials is being met by a new industry. There has been a noted increase in green roof systems and components, as well as installation and maintenance companies. It is expected that the ever increasing price for land in German cities along with an increasing population density will spur an even greater demand for green roofs. Germany is considered one of the greenest countries in the world, due to public concern for all forms of pollution, the maintenance of ecological balance, the preservation of flora and fauna, and a respect for nature. 6 refs.

  8. TECHNICAL CONSIDERATIONS FOR THE PLANNING OF ROOF GARDENS

    Directory of Open Access Journals (Sweden)

    Nizamettin KOÇ

    1998-01-01

    Full Text Available Increases in population, buildings, traffic density and air pollution is the most specific characteristics of metropol cities. These conditions effect the living quality negatively. That is why architectures and planners should find both aesthetic and functional planning approach in urban areas. Roof gardens, which affect positively urban ecology in many ways, have an important place in this approach. Planning aproach of roof gardens are rather different compare to ground level design. Structural elements under the roof gardens againist the infiltration of water. That is why it is important that roof garden plannings should have some layers shuclh as drainage, insulation, waterproofing, filter layers and irrigation andf drainage systems.

  9. STRUCTURE AND STABILITY OF MAIN ROOF AFTER ITS FRACTURE

    Institute of Scientific and Technical Information of China (English)

    朱德仁; 钱鸣高

    1990-01-01

    A serics of physical modelings in which a main roof is considered as a Kirchhoff plate supported or clammed by Winkler elastic foundation were performed to simulate the fracturing process of the main roof in longwall mining. Based on these modelings spatial structures of the main roof after its fracture are described, blocks of the fractured main roof are classified and their behaviors are analyzed in this paper. Additionally, two stability indexes of the structures are defined, and the factors affecting stability of the structures with different boundaries and geometric conditions are discussed.

  10. COMPARATIVE STUDY OF DIFFERENT TYPES OF ROOF AND INDOOR TEMPERATURES IN TROPICAL CLIMATE

    Directory of Open Access Journals (Sweden)

    Mrs. M. Ponni

    2015-04-01

    Full Text Available A roof provides protection to be safe from direct sunlight. From the shelter, shadow alone is not expected. Durability, sustainability, less life cycle cost, and low maintenance cost are expected from a selected roof. The world has a thirst to have a best roof. No roof will fulfil the requirement of humanity since the climatic conditions are different. Hence the roof should be selected according to the prevailing climate. And the roof selection depends on the need, taste and the spending capability of the house owner. Thatched shed, tiles covered roof, light roofs either using galvanized sheets or asbestos sheets, painted or unpainted metal sheets, RCC, Green roof, Roof pond, insulated roof, reflective roof, and cool roof are the roofs so far brought into use. Whatever be the roof, it should provide thermal comfort. Thermal comfort is felt through the thermal experience of the occupants. Thermal experience depends on the indoor temperature. Energy efficiency of a building is highly based on the indoor ambient temperature. Energy efficiency in buildings is compelling, cost effective, saves money and useful to compromise resource energy shortage. A light roof named as Single Decker (SID and an insulated double roof using hybrid technique named as (DOD are taken for this study. Among the selected roofs the DOD provides a better thermal performance and thermal comfort. The study has been carried out for the summer peak period in April 2014. Thermal performance and indoor temperature of the DOD is compared with other roof studies.

  11. Entire cities could benefit from green roofs : Heleen Mees is investigating how five metropolises are greenifying their roofs

    OpenAIRE

    Mees, Heleen

    2014-01-01

    Rotterdam is making good progress with its creation of green roofs. Heleen Mees, researcher at Utrecht University, drew this conclusion from her research, in which she compared the green roof policy of four different cities with that of Rotterdam. Rotterdam awards grants to those wishing to create a green roof, thereby helping to promote the general acceptance of green roofs in the city. However, the researcher thinks this policy should be followed up: “You can’t award grants forever.”

  12. Green roof systems: a study of public attitudes and preferences in southern Spain.

    Science.gov (United States)

    Fernandez-Cañero, Rafael; Emilsson, Tobias; Fernandez-Barba, Carolina; Herrera Machuca, Miguel Ángel

    2013-10-15

    This study investigates people's preconceptions of green roofs and their visual preference for different green roof design alternatives in relation to behavioral, social and demographical variables. The investigation was performed as a visual preference study using digital images created to represent eight different alternatives: gravel roof, extensive green roof with Sedums not in flower, extensive green roof with sedums in bloom, semi-intensive green roof with sedums and ornamental grasses, semi-intensive green roof with shrubs, intensive green roof planted with a lawn, intensive green roof with succulent and trees and intensive green roof with shrubs and trees. Using a Likert-type scale, 450 respondents were asked to indicate their preference for each digital image. Results indicated that respondents' sociodemographic characteristics and childhood environmental background influenced their preferences toward different green roof types. Results also showed that green roofs with a more careful design, greater variety of vegetation structure, and more variety of colors were preferred over alternatives.

  13. Estimating Heat and Mass Transfer Processes in Green Roof Systems: Current Modeling Capabilities and Limitations (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Tabares Velasco, P. C.

    2011-04-01

    This presentation discusses estimating heat and mass transfer processes in green roof systems: current modeling capabilities and limitations. Green roofs are 'specialized roofing systems that support vegetation growth on rooftops.'

  14. Utilisation of X-Ray computed microtomography for evaluation of iron sulphide distribution in roofing slate

    Science.gov (United States)

    Souček, Kamil; Daněk, Tomáš; Vavro, Martin; Botula, Jiří

    2016-04-01

    Roofing slate represents a traditional natural stone used for centuries for roofing and other construction applications in various types of buildings. Quality roofing slate must be primarily splittable into large, thin and waterproof tiles. In addition, it must be stable in colour and resistant against weathering. The abundance of mineral phases that weather easily or minerals that are long-term unstable has the effect of reducing the durability of slates in exterior conditions. One of the most problematic rock components, which are in a larger or smaller extent present in almost all slates, are iron sulphides, such as pyrite, marcasite or pyrrhotite. Under common atmospheric conditions, these minerals tend to oxidise, which leads to the formation of limonite and sulphuric acid. As a consequence of the origin of red-brown Fe oxyhydroxides, the undesirable colour changes of the slate may occur. But the most serious problem which occurs during this process is the changes in volume. This can cause disintegration of slate depending on the form of the iron sulphide occurrence. The content and size distribution of iron sulphides in roofing slate is normally determined using the microscopic analysis in transmitted light, combined with the observation in reflected light. For quantitative determination of iron sulphides in slate, the X-Ray powder diffraction is also often used. The results of the microscopic and X-Ray analyses need to be mutually compared and should not differ fundamentally. This paper is focused on the assessing the possibility of application of the X-Ray computed microtomography (CT) as a new complementary technique enabling the analysis of content and size (volume) distribution of iron sulphides in roofing slate. The X-Ray CT study was conducted using an XT H 225 ST industrial micro-tomographic system made by Nikon Metrology NV. Studied samples were reconstructed using the CT Pro 3D software (Nikon Metrology NV). The visualisation and analysis software

  15. Traumatic asphyxia--fatal accident in an automatic revolving door.

    Science.gov (United States)

    Cortis, J; Falk, J; Rothschild, M A

    2015-09-01

    Due to continuing modernisation, the number of automatic doors in routine use, including powered revolving doors, has increased in recent years. Automatic revolving doors are found mostly in department stores, airports, railway stations and hospitals. Although safety arrangements and guidelines concerning the installation of automatic doors are in existence, their disregard in conjunction with obsolete or incorrect installation can lead to fatal accidents. In this report, a 19-month-old boy is described whose right arm was caught between the elements of an automatic revolving door. As a direct result of rescue attempts, the child's body was drawn further into the narrow gap between elements of the door. To get the boy's body out of the 4-cm-wide gap between the fixed outer wall of the revolving door and the revolving inner, back-up batteries had to be disconnected so as to stop the electrical motor powering the door. Cardiopulmonary resuscitation was begun immediately after the rescue but was unsuccessful; the child was declared dead at the hospital he was taken to. The cause of death was a combination of compression-related skull and brain injury together with thoracic compression. This case shows an outstanding example of the preventive aspect as a special task of forensic medicine. Additionally, it serves as a warning for the correct installation and use of automatic revolving doors. Even so, small children should not use these doors on their own, but only with an alert companion, so as to prevent further fatal accidents of this sort.

  16. Comparing wildlife habitat and biodiversity across green roof type

    Energy Technology Data Exchange (ETDEWEB)

    Coffman, R.R. [Oklahoma Univ., Tulsa, OK (United States). Dept. of Landscape Architecture

    2007-07-01

    Green roofs represent restorative practices within human dominated ecosystems. They create habitat, increase local biodiversity, and restore ecosystem function. Cities are now promoting this technology as a part of mitigation for the loss of local habitat, making the green roof necessary in sustainable development. While most green roofs create some form of habitat for local and migratory fauna, some systems are designed to provide specific habitat for species of concern. Despite this, little is actually known about the wildlife communities inhabiting green roofs. Only a few studies have provided broad taxa descriptions across a range of green roof habitats, and none have attempted to measure the biodiversity across green roof class. Therefore, this study examined two different vegetated roof systems representative of North America. They were constructed under alternative priorities such as energy, stormwater and aesthetics. The wildlife community appears to be a result of the green roof's physical composition. Wildlife community composition and biodiversity is expected be different yet comparable between the two general types of green roofs, known as extensive and intensive. This study recorded the community composition found in the two classes of ecoroofs and assessed biodiversity and similarity at the community and group taxa levels of insects, spiders and birds. Renyi family of diversity indices were used to compare the communities. They were further described through indices and ratios such as Shannon's, Simpson's, Sorenson and Morsita's. In general, community biodiversity was found to be slightly higher in the intensive green roof than the extensive green roof. 26 refs., 4 tabs., 4 figs.

  17. Roof renovation of buildings 128 and 129

    CERN Multimedia

    2015-01-01

    The roof renovation of buildings 128 and 129 is scheduled to take place from 17 August to 15 October 2015.   During this period, access to the "raw material" workshop will be limited and controlled due to asbestos removal. Collecting your orders directly from the building will be difficult, or even impossible, and urgent requests will be difficult to carry out. We therefore ask you to create your requests via EDH, so that delivery may be carried out as soon as possible. Thank you for your understanding. GS Department

  18. Load-Bearing Capacity of Roof Trusses

    DEFF Research Database (Denmark)

    Sørensen, John Dalsgaard; Damkilde, Lars; Munch-Andersen, J.

    2004-01-01

    systems such as roof trusses are established and statistical characteristics of the load bearing capacity are determined. The results show that there is a significant increase in the characteristic (nominal) value and a reduction in the coefficient of variation (COV) for typical loads such as permanent......-sections with low strength and stiffness will generally not have large load effects. Further, there can be system effects due to non-linear material behavior. In this paper a stochastic model is established for the bending strength and stiffness of timber beams. Next, stochastic models for typical timber structural...

  19. The Geometric Theory of Roof Reflector Resonators

    Science.gov (United States)

    1976-12-01

    with solid state lasers, beginning in 1967. Soncini and Svelto (Refs 39 and 40) and Cubeddu, Polloni, Sacchi, and Svelto (Ref 11) have used pairs of 900...used by these authors is shown in Fig. 5. 13 In all experiments the output was found to be highly repeatable from pulse to pulse. Soncini and Svelto ...DeLang and Boumhuis (Fig. 4(b) ) and Soncini and Svelto (Fig. 5 ) have observed in their lasers are the samn except that iii the former the roof

  20. High Efficiency Solar Integrated Roof Membrane Product

    Energy Technology Data Exchange (ETDEWEB)

    Partyka, Eric; Shenoy, Anil

    2013-05-15

    This project was designed to address the Solar Energy Technology Program objective, to develop new methods to integrate photovoltaic (PV) cells or modules within a building-integrated photovoltaic (BIPV) application that will result in lower installed cost as well as higher efficiencies of the encapsulated/embedded PV module. The technology assessment and development focused on the evaluation and identification of manufacturing technologies and equipment capable of producing such low-cost, high-efficiency, flexible BIPV solar cells on single-ply roofing membranes.

  1. 40 CFR 205.55-5 - Labeling-exterior. [Reserved

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 24 2010-07-01 2010-07-01 false Labeling-exterior. 205.55-5 Section 205.55-5 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) NOISE ABATEMENT PROGRAMS TRANSPORTATION EQUIPMENT NOISE EMISSION CONTROLS Medium and Heavy Trucks § 205.55-5...

  2. On sets without tangents and exterior sets of a conic

    CERN Document Server

    Van de Voorde, Geertrui

    2012-01-01

    A set without tangents in $\\PG(2,q)$ is a set of points S such that no line meets S in exactly one point. An exterior set of a conic $\\mathcal{C}$ is a set of points $\\E$ such that all secant lines of $\\E$ are external lines of $\\mathcal{C}$. In this paper, we first recall some known examples of sets without tangents and describe them in terms of determined directions of an affine pointset. We show that the smallest sets without tangents in $\\PG(2,5)$ are (up to projective equivalence) of two different types. We generalise the non-trivial type by giving an explicit construction of a set without tangents in $\\PG(2,q)$, $q=p^h$, $p>2$ prime, of size $q(q-1)/2-r(q+1)/2$, for all $0\\leq r\\leq (q-5)/2$. After that, a different description of the same set in $\\PG(2,5)$, using exterior sets of a conic, is given and we investigate in which ways a set of exterior points on an external line $L$ of a conic in $\\PG(2,q)$ can be extended with an extra point $Q$ to a larger exterior set of $\\mathcal{C}$. It turns out that ...

  3. 36 CFR 910.38 - Building exterior illumination.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 3 2010-07-01 2010-07-01 false Building exterior illumination. 910.38 Section 910.38 Parks, Forests, and Public Property PENNSYLVANIA AVENUE DEVELOPMENT... specified in the Pennsylvania Avenue Lighting Plan of the Corporation. ...

  4. Spinoza y el naturalismo: el problema del mundo exterior

    OpenAIRE

    Barrero, Tomás

    2010-01-01

    El conocimiento del mundo exterior se presenta como un problema difícil para el racionalismo clásico, encarnado en Descartes. En este ensayo, se examinará el argumento que permite a Spinoza solucionar esta dificultad mediante un naturalismo muy singular que determina un profundo sesgo anticartesiano en su obra.

  5. Modeling of Exterior Rotor Permanent Magnet Machines with Concentrated Windings

    NARCIS (Netherlands)

    Vu Xuan, H.

    2012-01-01

    In this thesis modeling, analysis, design and measurement of exterior rotor permanent magnet (PM) machines with concentrated windings are dealt with. Special attention is paid to slotting effect. The PM machine is integrated in flywheel and used for small-scale ship application. Analytical model and

  6. Non-static vacuum strings: exterior and interior solutions

    Energy Technology Data Exchange (ETDEWEB)

    Stein-Schabes, J.A.

    1986-01-01

    New non-static cylindrically symmetric solutions of Einsteins's equations are presented. Some of these solutions represent string-like objects. An exterior vacuum solution is matched to a non-vacuum interior solution for different forms of the energy-momentum tensor. They generalize the standard static string. 12 refs.

  7. Second order perturbations of rotating bodies in equilibrium; the exterior vacuum problem

    CERN Document Server

    MacCallum, M A H; Vera, R; Callum, Malcolm A. H. Mac; Mars, Marc; Vera, Raul

    2005-01-01

    We study the exterior vacuum problem for first and second order stationary and axially symmetric perturbations of static bodies. The boundary conditions and their compatibility for the existence of an asymptotically flat exterior solution are discussed.

  8. DIFFERENT ROOF BEHAVIOUR UNDER DIFFERENT UPPER MINING BOUNDARY CONDITION IN DATONG

    Institute of Scientific and Technical Information of China (English)

    康立勋

    1997-01-01

    Understanding roof behaviour and immediate roof failure patterns of Iongwall face is a prerequisite for establishing correct roof control theory and appplying effective roof control measures. Roof behaviour and immediate roof failure pattern have a close relationship with upper mining boundary conditions of Iongwall face. According to actual situation of Datong Mining Area, upper mining boundary conditions of Iongwall face have been classified into 5 types in this paper. Roof behaviour and immediate roof failure pattern under each upper mining boundary condition are discussed in details.

  9. Numerical Method for Darcy Flow Derived Using Discrete Exterior Calculus

    Science.gov (United States)

    Hirani, A. N.; Nakshatrala, K. B.; Chaudhry, J. H.

    2015-05-01

    We derive a numerical method for Darcy flow, and also for Poisson's equation in mixed (first order) form, based on discrete exterior calculus (DEC). Exterior calculus is a generalization of vector calculus to smooth manifolds and DEC is one of its discretizations on simplicial complexes such as triangle and tetrahedral meshes. DEC is a coordinate invariant discretization, in that it does not depend on the embedding of the simplices or the whole mesh. We start by rewriting the governing equations of Darcy flow using the language of exterior calculus. This yields a formulation in terms of flux differential form and pressure. The numerical method is then derived by using the framework provided by DEC for discretizing differential forms and operators that act on forms. We also develop a discretization for a spatially dependent Hodge star that varies with the permeability of the medium. This also allows us to address discontinuous permeability. The matrix representation for our discrete non-homogeneous Hodge star is diagonal, with positive diagonal entries. The resulting linear system of equations for flux and pressure are saddle type, with a diagonal matrix as the top left block. The performance of the proposed numerical method is illustrated on many standard test problems. These include patch tests in two and three dimensions, comparison with analytically known solutions in two dimensions, layered medium with alternating permeability values, and a test with a change in permeability along the flow direction. We also show numerical evidence of convergence of the flux and the pressure. A convergence experiment is included for Darcy flow on a surface. A short introduction to the relevant parts of smooth and discrete exterior calculus is included in this article. We also include a discussion of the boundary condition in terms of exterior calculus.

  10. 40 CFR 63.1043 - Standards-Separator floating roof.

    Science.gov (United States)

    2010-07-01

    ...) National Emission Standards for Oil-Water Separators and Organic-Water Separators § 63.1043 Standards... controlling air emissions from an oil-water separator or organic-water separator using a floating roof. (b... floating roof shall be equipped with two continuous seals, one above the other, between the wall of...

  11. Integral design methodology for collaborative design of sustainable roofs

    NARCIS (Netherlands)

    Quanjel, E.M.C.J.

    2006-01-01

    Normally the roof is the part of building which gets minimal attention to use for integration with the comfort system of the building. This is striking, as the roof is an important possible building component for containing sustainable energy systems. The sustainable energy possible options are ofte

  12. Fourier analysis of conductive heat transfer for glazed roofing materials

    Energy Technology Data Exchange (ETDEWEB)

    Roslan, Nurhana Lyana; Bahaman, Nurfaradila; Almanan, Raja Noorliyana Raja; Ismail, Razidah [Faculty of Computer and Mathematical Sciences, Universiti Teknologi MARA, 40450 Shah Alam, Selangor (Malaysia); Zakaria, Nor Zaini [Faculty of Applied Sciences, Universiti Teknologi MARA, 40450 Shah Alam, Selangor (Malaysia)

    2014-07-10

    For low-rise buildings, roof is the most exposed surface to solar radiation. The main mode of heat transfer from outdoor via the roof is conduction. The rate of heat transfer and the thermal impact is dependent on the thermophysical properties of roofing materials. Thus, it is important to analyze the heat distribution for the various types of roofing materials. The objectives of this paper are to obtain the Fourier series for the conductive heat transfer for two types of glazed roofing materials, namely polycarbonate and polyfilled, and also to determine the relationship between the ambient temperature and the conductive heat transfer for these materials. Ambient and surface temperature data were collected from an empirical field investigation in the campus of Universiti Teknologi MARA Shah Alam. The roofing materials were installed on free-standing structures in natural ventilation. Since the temperature data are generally periodic, Fourier series and numerical harmonic analysis are applied. Based on the 24-point harmonic analysis, the eleventh order harmonics is found to generate an adequate Fourier series expansion for both glazed roofing materials. In addition, there exists a linear relationship between the ambient temperature and the conductive heat transfer for both glazed roofing materials. Based on the gradient of the graphs, lower heat transfer is indicated through polyfilled. Thus polyfilled would have a lower thermal impact compared to polycarbonate.

  13. Green roof hydrologic performance and modeling: a review.

    Science.gov (United States)

    Li, Yanling; Babcock, Roger W

    2014-01-01

    Green roofs reduce runoff from impervious surfaces in urban development. This paper reviews the technical literature on green roof hydrology. Laboratory experiments and field measurements have shown that green roofs can reduce stormwater runoff volume by 30 to 86%, reduce peak flow rate by 22 to 93% and delay the peak flow by 0 to 30 min and thereby decrease pollution, flooding and erosion during precipitation events. However, the effectiveness can vary substantially due to design characteristics making performance predictions difficult. Evaluation of the most recently published study findings indicates that the major factors affecting green roof hydrology are precipitation volume, precipitation dynamics, antecedent conditions, growth medium, plant species, and roof slope. This paper also evaluates the computer models commonly used to simulate hydrologic processes for green roofs, including stormwater management model, soil water atmosphere and plant, SWMS-2D, HYDRUS, and other models that are shown to be effective for predicting precipitation response and economic benefits. The review findings indicate that green roofs are effective for reduction of runoff volume and peak flow, and delay of peak flow, however, no tool or model is available to predict expected performance for any given anticipated system based on design parameters that directly affect green roof hydrology.

  14. Hydrologic Restoration in the Urban Environment Using Green Roofs

    Directory of Open Access Journals (Sweden)

    Anna Palla

    2010-04-01

    Full Text Available Loss of natural soil and vegetation within the urban environment can significantly affect the hydrologic cycle by increasing storm water runoff rates and volumes. In order to mitigate these modifications in urban areas engineered systems are developed, such as green roofs, to mimic and replace functions (evapo-transpiration, infiltration, percolation which have been altered due to the impact of human development. Green roofs, also known as vegetated roof covers, eco-roofs or nature roofs, are composite complex layered structures with specific environmental benefits. They are increasingly being used as a source control measure for urban storm water management. Indeed, they are able to re-establish the natural water cycle processes and to operate hydrologic control over storm water runoff with a derived peak flow attenuation, runoff volume reduction and increase of the time of concentration. Furthermore green roofs exhibit the capacity to reduce storm water pollution; they generally act as a storage device, consequently pollutants are accumulated in the substrate layer and released when intensive rainwater washes them out. In order to investigate the hydrologic response of a green roof, the University of Genova recently developed a joint laboratory and full-scale monitoring programme by installing a “controlled” laboratory test-bed with known rainfall input and a companion green roof experimental site (40 cm depth in the town of Genoa. In the paper, data collected during the monitoring programme are presented and compared with literature data.

  15. Requirements of inverted roofs with a drainage layer

    DEFF Research Database (Denmark)

    Leimer, Hans-Peter; Rode, Carsten; Künzel, Hartwig

    2005-01-01

    This contribution illustrates the application of the standard EN ISO 6946 regarding the heat loss of an inverted roof for different regions of Europe. An addendum to the standard (EN ISO 6946:1996/A1, 2003) introduces a correction to the thermal transmittance of inverted roofs due to rain water f...

  16. Hygrothermal Performance of West Coast Wood Deck Roofing System

    Energy Technology Data Exchange (ETDEWEB)

    Pallin, Simon B [ORNL; Kehrer, Manfred [ORNL; Desjarlais, Andre Omer [ORNL

    2014-02-01

    Simulations of roofing assemblies are necessary in order to understand and adequately predict actual the hygrothermal performance. At the request of GAF, simulations have been setup to verify the difference in performance between white and black roofing membrane colors in relation to critical moisture accumulation for traditional low slope wood deck roofing systems typically deployed in various western U.S. Climate Zones. The performance of these roof assemblies has been simulated in the hygrothermal calculation tool of WUFI, from which the result was evaluated based on a defined criterion for moisture safety. The criterion was defined as the maximum accepted water content for wood materials and the highest acceptable moisture accumulation rate in relation to the risk of rot. Based on the criterion, the roof assemblies were certified as being either safe, risky or assumed to fail. The roof assemblies were simulated in different western climates, with varying insulation thicknesses, two different types of wooden decking, applied with varying interior moisture load and with either a high or low solar absorptivity at the roof surface (black or white surface color). The results show that the performance of the studied roof assemblies differs with regard to all of the varying parameters, especially the climate and the indoor moisture load.

  17. Hygrothermal Performance of West Coast Wood Deck Roofing System

    Energy Technology Data Exchange (ETDEWEB)

    Pallin, Simon B [ORNL; Kehrer, Manfred [ORNL; Desjarlais, Andre Omer [ORNL

    2014-02-01

    Simulations of roofing assemblies are necessary in order to understand and adequately predict actual the hygrothermal performance. At the request of GAF, simulations have been setup to verify the difference in performance between white and black roofing membrane colors in relation to critical moisture accumulation for traditional low slope wood deck roofing systems typically deployed in various western U.S. Climate Zones. The performance of these roof assemblies has been simulated in the hygrothermal calculation tool of WUFI, from which the result was evaluated based on a defined criterion for moisture safety. The criterion was defined as the maximum accepted water content for wood materials and the highest acceptable moisture accumulation rate in relation to the risk of rot. Based on the criterion, the roof assemblies were certified as being either safe, risky or assumed to fail. The roof assemblies were simulated in different western climates, with varying insulation thicknesses, two different types of wooden decking, applied with varying interior moisture load and with either a high or low solar absorptivity at the roof surface (black or white surface color). The results show that the performance of the studied roof assemblies differs with regard to all of the varying parameters, especially the climate and the indoor moisture load.

  18. Extensive Green Roof Research Program at Colorado State University

    Science.gov (United States)

    In the high elevation, semi-arid climate of Colorado, green roofs have not been scientifically tested. This research examined alternative plant species, media blends, and plant interactions on an existing modular extensive green roof in Denver, Colorado. Six plant species were ev...

  19. Corrosion-Resistant Roof with Integrated Photovoltaic Power System

    Science.gov (United States)

    2014-02-01

    metal roof panel are being monitored using a non-operational mockup of a PV module and roofing panel installed on the exposure rack. Four experi...conditions Examination of 1 year’s data downloaded from the corrosion sensors placed between the metal panel and PV module on the system mockup in

  20. The Discharge Coefficient of a Centre-Pivot Roof Window

    DEFF Research Database (Denmark)

    Iqbal, Ahsan; Afshari, Alireza; Nielsen, Peter V.

    2012-01-01

    value of discharge coefficient is used. The constant value of discharge coefficient leads to deceptive airflow estimation in the cases of centre-pivot roof windows. The object of this paper is to study and evaluate the discharge coefficient of the centre pivot roof window. Focus is given...

  1. U-value measurements on a roof window

    DEFF Research Database (Denmark)

    Duer, Karsten

    1998-01-01

    This report describes the results of the U-value measurements performed on a roof window. The work is as a part of the development of an ISO/CEN standard measuring procedure for roof windows.The measurements have been performed using the procedures given in ISO 12567 draft version 1998...

  2. Opportunities Green Roofs Can Offer Ghanaians and their Cities

    African Journals Online (AJOL)

    Lone Star College System

    2015-08-17

    Aug 17, 2015 ... Review. Green roofs: A possible best management practice for enhancing the ... development in Ghana in this era of climate change and variability. Key words: Green roof, .... mitigation of urban heat island effect and indoor energy consumption. ..... through buildings, air pollution, emission of greenhouse.

  3. COMPARISON OF RESULTS OF THERMAL TESTS OF BALCONY DOORS

    Directory of Open Access Journals (Sweden)

    Golubev Stanislav Sergeevich

    2012-10-01

    Full Text Available Results of thermal tests of balcony doors are presented in the article. In the course of the research project, two types of doors were tested. The first type represents a PVC frame door (width 82 mm; it has a triple glazing (4K-16Ar-4-16Ar-K4; its blank part represents a polystyrene sandwich panel (width 40 mm. The second type represents a PVC frame door (width 82 mm, that has a triple glazing (4K-16Ar-4-16Ar-K4 and composite PVC panels. The testing procedure and processing results are described in the article. The test has demonstrated that the thermal resistance value of the balcony door of the first type exceeds the thermal resistance value of the balcony door of the second type.

  4. Design Report for ACP Hot Cell Rear Door

    Energy Technology Data Exchange (ETDEWEB)

    Ku, J. H.; Kwon, K. C.; Choung, W. M.; Cho, I. J.; Kook, D. H.; Lee, W. K.; You, G. S.; Lee, E. P.; Park, S. W

    2005-12-15

    A hot-cell facility was constructed at the IMEF building for the demonstrate ACP process. ACP hot-cell consists of process cell and maintenance cell, and each cell has rear door. Since this facility was constructed at basement floor, all process materials, equipment and radioactive materials are take in and out through the rear door. Also, this door can be an access route of workers for the maintenance works. Therefore ACP hot-cell rear doors must maintain the radiation shielding, sealing, mechanical and structural safety. This report presents design criteria, design contents of each part and driving part. It was confirmed that the rear doors sufficiently maintain the safety through the structural analysis and shielding analysis. Also, it was confirmed that the rear doors were constructed as designed by the gamma scanning test after the installation.

  5. A Roof for the Lion's House

    Science.gov (United States)

    1978-01-01

    Fans of the National Football League's Detroit Lions don't worry about gameday weather. Their magnificent new Pontiac Stadium has a domed, air-supported, fabric roof that admits light but protects the playing field and patrons from the elements. The 80,000-seat "Silverdome" is the world's largest fabric-covered structure-and aerospace technology played an important part in its construction. The key to economical construction of the Silverdome-and many other types of buildings-is a spinoff of fiber glass Beta yarn coated with Teflon TFE fluorocarbon resin. The big advance it offers is permanency. Fabric structures-tents, for example have been around since the earliest years of human civilization. But their coverings-hides, canvas and more recently plastics-were considered temporary; though tough, these fabrics were subject to weather deterioration. Teflon TFE-coated Beta Fiberglas is virtually impervious to the effects of weather and sunlight and it won't stretch, shrink, mildew or rot, thus has exceptional longevity; it is also very strong, lightweight, flame resistant and requires no periodic cleaning, because dirt will not stick to the surface of Teflon TFE. And to top all that, it costs only 30 to 40 percent as much as conventional roofing.

  6. Greenbacks from green roofs: forging a new industry in Canada

    Energy Technology Data Exchange (ETDEWEB)

    Peck, S. W.; Callaghan, C. [Peck and Associates, Toronto, ON (Canada); Bass, B. [Environment Canada, Toronto, ON (Canada); Kuhn, M. [Toronto, ON (Canada)

    1999-03-01

    This report provides a comprehensive review of the qualitative and quantitative benefits of green roof and vertical garden technologies, explains the nature of roof greening and green roof systems, examines the barriers to their more rapid diffusion into Canadian markets, and makes recommendations as to how how these barriers may be overcome. Two basic types of green roof systems, extensive and intensive, are identified. Extensive green roofs are characterized by their low weight, low capital cost and low maintenance. Intensive green roofs, by contrast, are heavier, more costly to establish, require intensive planting and higher maintenance. Both types of green roofs may be further subdivided into accessible or inaccessible. Accessible green roofs are flat, outdoor open spaces intended for use as gardens or terraces, while inaccessible roofs are only accessible for periodic maintenance. 'Vertical gardens' are a type of extensive green roof, characterized by the growing of plants on or up against the facade of buildings. The many benefits of green roof or vertical garden technologies include energy cost savings due to increased insulation and improved protection of the roof membrane, air quality improvements, new employment opportunities for a wide range of people including suppliers of roof membranes and related products, and social benefits such as improved aesthetics, health and horticultural therapy. Barriers to diffusion in Canada have been identified as lack of awareness, lack of incentives to implement, cost implications, lack of technical standards, few existing examples and risks associated with uncertainty. The recommendations to overcome market barriers are intended to address these barriers, i.e. they call for increased efforts to generate awareness through addressing the knowledge availability issue, and through high profile demonstration projects, government-sponsored technology diffusion, financial incentives to overcome cost-based barriers

  7. Thermal Behavior of Green Roofs Applied to Tropical Climate

    Directory of Open Access Journals (Sweden)

    Grace Tibério Cardoso

    2013-01-01

    Full Text Available The main goal of this paper is to present results on an experimental field about the green roofs thermal behavior, compared to other traditional roof covering systems. On the one hand, it intends to describe shortly the constructive system of a green roof with a lightweight building system, which has a sustainable building materials character and, on the other, it worries with the water reuse and with the run-off delay. The main methodological procedure adopted to study the thermal behavior of green roof was installing thermocouples to collect surface temperatures and indoor air, later comparing them with existing prototypes in an experimental plot. The thermal behavior analysis of cover systems was assessed by a representative episode of the climate fact, based on the dynamic climate approach. The experimental results from internal air temperature measurements show that the green roofs applied to warm and dry climates also provide an interesting time lag with surface and internal air temperature reduction.

  8. A pilot study to evaluate runoff quantity from green roofs.

    Science.gov (United States)

    Lee, Ju Young; Lee, Min Jung; Han, Mooyoung

    2015-04-01

    The use of green roofs is gaining increased recognition in many countries as a solution that can be used to improve environmental quality and reduce runoff quantity. To achieve these goals, pilot-scale green roof assemblies have been constructed and operated in an urban setting. From a stormwater management perspective, green roofs are 42.8-60.8% effective in reducing runoff for 200 mm soil depth and 13.8-34.4% effective in reducing runoff for 150 mm soil depth. By using Spearman rank correlation analysis, high rainfall intensity was shown to have a negative relationship with delayed occurrence time, demonstrating that the soil media in green roofs do not efficiently retain rainwater. Increasing the number of antecedent dry days can help to improve water retention capacity and delay occurrence time. From the viewpoint of runoff water quality, green roofs are regarded as the best management practice by filtration and adsorption through growth media (soil).

  9. Experimental analysis of green roof substrate detention characteristics.

    Science.gov (United States)

    Yio, Marcus H N; Stovin, Virginia; Werdin, Jörg; Vesuviano, Gianni

    2013-01-01

    Green roofs may make an important contribution to urban stormwater management. Rainfall-runoff models are required to evaluate green roof responses to specific rainfall inputs. The roof's hydrological response is a function of its configuration, with the substrate - or growing media - providing both retention and detention of rainfall. The objective of the research described here is to quantify the detention effects due to green roof substrates, and to propose a suitable hydrological modelling approach. Laboratory results from experimental detention tests on green roof substrates are presented. It is shown that detention increases with substrate depth and as a result of increasing substrate organic content. Model structures based on reservoir routing are evaluated, and it is found that a one-parameter reservoir routing model coupled with a parameter that describes the delay to start of runoff best fits the observed data. Preliminary findings support the hypothesis that the reservoir routing parameter values can be defined from the substrate's physical characteristics.

  10. APPLICATION OF THE ROOF DISTURBANCETO MONITORING AND PREDICTINGTHE GROUND PRESSURE

    Institute of Scientific and Technical Information of China (English)

    付国彬; 钱鸣高

    1992-01-01

    Based on study of the influence of main roof fracture on ground pressure,this paper considered the immediate roof as a semi-infinite long beam on a Winkler elastic foundation. In the model the coal seam is the foundation and the pressure caused by rnian roof deflection is the load.Having solved the model and analyzed relevant factors,the authors indicate that the disturbance caused by the breakage of the mian roof can be observed in both gates of iongwaii face and explain why it can be. The paper points out that the applicability of the method to obtain the disturbance information by measuring the loads on supports is wider than that by measuring the roof convergence rate. The results are useful for monitoring and predicting ground pressure.

  11. Modelling of green roof hydrological performance for urban drainage applications

    DEFF Research Database (Denmark)

    Locatelli, Luca; Mark, Ole; Mikkelsen, Peter Steen

    2014-01-01

    Green roofs are being widely implemented for stormwater management and their impact on the urban hydrological cycle can be evaluated by incorporating them into urban drainage models. This paper presents a model of green roof long term and single event hydrological performance. The model includes...... from 3 different extensive sedum roofs in Denmark. These data consist of high-resolution measurements of runoff, precipitation and atmospheric variables in the period 2010–2012. The hydrological response of green roofs was quantified based on statistical analysis of the results of a 22-year (1989...... and that the mean annual runoff is not linearly related to the storage. Green roofs have therefore the potential to be important parts of future urban stormwater management plans....

  12. PNEUMATIC - LOGIC SYNTHESIS OF BUS DOOR FROM ASPECT OF AUTOMATION

    Directory of Open Access Journals (Sweden)

    Slobodan Stefanovic

    2015-01-01

    Full Text Available The paper presents a logic synthesis procedure pneumatic control of the door of the bus for suburban traffic. Minimization of pneumatic control is determined graphically by Weitz – Carnot method. It also shows all pneumatic components belonging to installations used for opening and closing the door of the bus. Finally it is shown the basic maintenance of pneumatic system of the bus door.

  13. Opening the doors: building brand awareness.

    Science.gov (United States)

    John, Judith; McCartney, Rob

    2006-01-01

    In search of a credible and cost-effective way to promote Mount Sinai Hospital (Mount Sinai) and educate a broad public, Mount Sinai opened its doors wide to The Globe and Mail (The Globe). The result was a three-part national feature series that told Mount Sinai's compelling story, provided third-party credibility and confirmed the value of proactive media relations. The series engaged our staff, energized our volunteers and reached both stakeholders and the general public on an emotional level. It also generated the more than dollars 6 million worth of equivalent advertising space it would have required for Mount Sinai to reach this national audience.

  14. Bodemverontreiniging en de opname van lood door moestuingewassen : risico’s van lood door bodemverontreiniging

    NARCIS (Netherlands)

    Otte, P.F.; Römkens, P.F.A.M.; Rietra, R.P.J.J.; Lijzen, J.P.A.

    2012-01-01

    Lood uit bodemverontreinigingen wordt opgenomen door moestuingewassen die daarop worden geteeld. Deze gewassen kunnen een gezondheidsrisico vormen als zij worden geconsumeerd. Uit deze studie van het RIVM en Alterra blijkt dat bij hoge concentraties lood in de bodem de opname minder wordt. Hierdoor

  15. Patterns of post-cabinet careers: When one door closes another door opens?

    NARCIS (Netherlands)

    Dörrenbächer, N.

    2016-01-01

    This article tackles the question to what extent former cabinet members go through the so-called revolving door by starting a second career in the private sector, and what factors make them likely to do so. After a cabinet position, career advancement in the political and public sector is difficult.

  16. Mobilization and distribution of lead originating from roof dust and wet deposition in a roof runoff system.

    Science.gov (United States)

    Yu, Jianghua; Yu, Haixia; Huang, Xiaogu

    2015-12-01

    In this research, the mobilization and distribution of lead originating in roof dust and wet deposition were investigated within a roof dust-rooftop-runoff system. The results indicated that lead from roof dust and wet deposition showed different transport dynamics in runoff system and that this process was significantly influenced by the rainfall intensity. Lead present in the roof dust could be easily washed off into the runoff, and nearly 60 % of the total lead content was present in particulate form. Most of the lead from the roof dust was transported during the late period of rainfall; however, the lead concentration was higher for several minutes at the rainfall beginning. Even though some of the lead from wet deposition, simulated with a standard isotope substance, was adsorbed onto adhered roof dust and/or retained on rooftop in runoff system, most of it (50-82 %) remained as dissolved lead in the runoff for rainfall events of varying intensity. Regarding the distribution of lead in the runoff system, the results indicated that it could be carried in the runoff in dissolved and particulate form, be adsorbed to adhered roof dust, or remain on the rooftop because of adsorption to the roof material. Lead from the different sources showed different distribution patterns that were also related to the rainfall intensity. Higher rainfall intensity resulted in a higher proportion of lead in the runoff and a lower proportion of lead remaining on the rooftop.

  17. Entire cities could benefit from green roofs : Heleen Mees is investigating how five metropolises are greenifying their roofs

    NARCIS (Netherlands)

    Mees, Heleen

    2014-01-01

    Rotterdam is making good progress with its creation of green roofs. Heleen Mees, researcher at Utrecht University, drew this conclusion from her research, in which she compared the green roof policy of four different cities with that of Rotterdam. Rotterdam awards grants to those wishing to create a

  18. Ombuds’ corner: Open door and confidentiality

    CERN Multimedia

    Vincent Vuillemin

    2013-01-01

    For the Open Days, CERN will be transparent for all visitors. It's also the occasion to remember that the Ombuds' door is fully open every day of the year for all persons working for or on behalf of CERN.   The door is open, but as soon as it's closed for a discussion, the office becomes a place where total confidentiality is preserved. This may appear as a contradiction, no? The Ombuds is available to help everyone in all circumstances, but his clause of confidentiality prevents him from acting without the consent of his “visitors”. How can he possibly resolve the in-house conflicts in groups, or units, if all the parties do not voluntarily participate in its resolution? The answer is clear: the job of the Ombuds is to help the parties resolve their conflict by themselves. He will provide a few rules of communication, a process of mutual respect, suggest some possibilities that the parties may want to follow, and mediate the dispute so that people...

  19. Golden Jubilee Photos: Doors wide open

    CERN Multimedia

    2004-01-01

    http://www.cern.ch/cern50/ The reception area and visits desk (formerly PIO - Public Information Office) in 1972. Régine Chareyron (on the right), who has worked for the Visits Service for 35 years, is pictured here with Chantal Montuel and Cora Roth. CERN inaugurated its permanent visitor centre "Microcosm" in 1989. This brand new outreach facility added a crowning touch to CERN's tradition of openness in conducting its research activities. In keeping with Article II of the Convention, which stipulates that "the results of its (...) work shall be published or otherwise made available," CERN was already organising visits for the general public in the late 1950s, with members of the personnel doubling up as voluntary tour guides. By 1959, the Laboratory was opening its doors to almost 2 500 visitors a year. Ten years down the line, that number had risen to 12 700, and today CERN welcomes some 30 000 visitors through its doors every year. In addition, the Visits Service has developed teaching packs for sc...

  20. Stormwater quality from extensive green roofs in a subtropical region

    Science.gov (United States)

    Onis Pessoa, Jonas; Allasia, Daniel; Tassi, Rutineia; Vaz Viega, Juliana; Fensterseifer, Paula

    2016-04-01

    Green roofs have increasingly become an integral part of urban environments, mainly due to their aesthetic benefits, thermal comfort and efficiency in controlling excess runoff. However, the effects of this emerging technology in the qualitative characteristics of rainwater is still poorly understood. In this study was evaluated the effect of two different extensive green roofs (EGRs) and a traditional roof built with corrugated fiber cement sheets (control roof) in the quality of rainwater, in a subtropical climate area in the city of Santa Maria, in southern Brazil. The principal variant between the two EGRs were the type of plant species, time since construction, soil depth and the substrate characteristics. During the monitoring period of the experiment, between the months of April and December of 2015 fourteen rainfall events were selected for qualitative analysis of water from the three roofs and directly from rainfall. It was analyzed physical (turbidity, apparent color, true color, electrical conductivity, total solids, dissolved solids, suspended solids and temperature), chemical (pH, phosphate, total nitrogen, nitrate, nitrite, chloride, sulfate, BOD, iron and total hardness), heavy metals (copper, zinc, lead and chromium) and microbiological parameters (total coliforms and E. coli). It was also characterized the substrates used in both extensive green roofs. The results showed that the quality of the water drained from EGR s was directly influenced by their substrates (in turn containing significant levels of nutrients, organic matter and some metals). The passage of rainwater through green roofs and control roof resulted in the elevation of pH, allowing the conversion of the slightly acidic rainfall into basic water. Similarly, on both types of roofs occurred an increase of the values of most of the physical, chemical and microbiological parameters compared to rainwater. This same trend was observed for heavy metals, although with a much smaller degree

  1. Adventures on the roof of the world

    Science.gov (United States)

    Leslie,, David M.

    2013-01-01

    To conduct field biology requires tenacity, grit, and flexibility; to endeavor to achieve conservation success requires patience, persistence, and passion. The essence of field biology and the hope for conservation success are both reflected admirably in George B. Schaller's most recent book, Tibet Wild: A Naturalist's Journeys on the Roof of the World. I can think of no living biologist who embodies these characteristics more than Schaller does. Nearly 80 years old, he still regularly treks in faraway lands, observing and recording the natural history of species that the vast majority of us will never see in the wild. Schaller is a vanguard, and Tibet Wild, like his other books, is a sentinel of urgent conservation need.

  2. THE MODERN STYLE IN INTERIOR AND EXTERIOR DESIGN

    Directory of Open Access Journals (Sweden)

    Vaska Sandeva

    2016-07-01

    Full Text Available The style is a way of expression, which is characterized by all the features that distinguish it from the rest. In the art indicates overall characteristics of an artist or art school, direction or time. Modern design is difficult to define. The term "modern" refers to the impact of modern art to the design of interiors and exteriors. Modern design is defined more by its own trends, which is largely unchanged for several decades. One of the most important elements in modern design of interiors and exteriors is the form. Modern design uses geometric forms including rigid squares and rectangles, with a smooth, even and curved ends. Perfect circles and oval shapes are also common in modern design. Modern design is also plain and simple.

  3. Combining interior and exterior characteristics for remote sensing image denoising

    Science.gov (United States)

    Peng, Ni; Sun, Shujin; Wang, Runsheng; Zhong, Ping

    2016-04-01

    Remote sensing image denoising faces many challenges since a remote sensing image usually covers a wide area and thus contains complex contents. Using the patch-based statistical characteristics is a flexible method to improve the denoising performance. There are usually two kinds of statistical characteristics available: interior and exterior characteristics. Different statistical characteristics have their own strengths to restore specific image contents. Combining different statistical characteristics to use their strengths together may have the potential to improve denoising results. This work proposes a method combining statistical characteristics to adaptively select statistical characteristics for different image contents. The proposed approach is implemented through a new characteristics selection criterion learned over training data. Moreover, with the proposed combination method, this work develops a denoising algorithm for remote sensing images. Experimental results show that our method can make full use of the advantages of interior and exterior characteristics for different image contents and thus improve the denoising performance.

  4. A field study to evaluate runoff quality from green roofs.

    Science.gov (United States)

    Vijayaraghavan, K; Joshi, U M; Balasubramanian, R

    2012-03-15

    Green (vegetated) roofs are emerging as practical strategies to improve the environmental quality of cities. However, the impact of green roofs on the storm water quality remains a topic of concern to city planners and environmental policy makers. This study investigated whether green roofs act as a source or a sink of various metals (Na, K, Ca, Mg, Al, Fe, Cu, Cd, Pb, Zn, Mn, Cr, Ni, Li and Co), inorganic anions (NO3-, NO2-, PO4(3-), SO4(2-), Cl-, F- and Br-) and cation (NH4+). A series of green roof assemblies were constructed. Four different real rain events and several artificial rain events were considered for the study. Results showed that concentrations of most of the chemical components in runoff were highest during the beginning of rain events and subsided in the subsequent rain events. Some of the important components present in the runoff include Na, K, Ca, Mg, Li, Fe, Al, Cu, NO3-, PO4(3-) and SO4(2-). However, the concentration of these chemical components in the roof runoff strongly depends on the nature of substrates used in the green roof and the volume of rain. Based on the USEPA standards for freshwater quality, we conclude that the green roof used in this study is reasonably effective except that the runoff contains significant amounts of NO3- and PO4(3-).

  5. Comparative life cycle assessment of standard and green roofs.

    Science.gov (United States)

    Saiz, Susana; Kennedy, Christopher; Bass, Brad; Pressnail, Kim

    2006-07-01

    Life cycle assessment (LCA) is used to evaluate the benefits, primarily from reduced energy consumption, resulting from the addition of a green roof to an eight story residential building in Madrid. Building energy use is simulated and a bottom-up LCA is conducted assuming a 50 year building life. The key property of a green roof is its low solar absorptance, which causes lower surface temperature, thereby reducing the heat flux through the roof. Savings in annual energy use are just over 1%, but summer cooling load is reduced by over 6% and reductions in peak hour cooling load in the upper floors reach 25%. By replacing the common flat roof with a green roof, environmental impacts are reduced by between 1.0 and 5.3%. Similar reductions might be achieved by using a white roof with additional insulation for winter, but more substantial reductions are achieved if common use of green roofs leads to reductions in the urban heat island.

  6. Numerical analysis of application for induction caving roof

    Institute of Scientific and Technical Information of China (English)

    HU Jian-hua; ZHOU Ke-ping; LI Xi-bing; YANG Nian-ge; SU Jia-hong

    2005-01-01

    New method for handling roof of the base successive mining is proposed, which is induction caving in the roof. The key is that it is made certain to the station of the space-time in the induction caving roof, as the stress is released with the mining process. And applying the catastrophe theory, the influencing factors of induction caving roof are studied in the emptied areas, such as the mechanical property of the surrounding rock, the area of the gob,the scope and dimension of tensile stress. The results show that the key factor is the area of the gob to the method of the induction caving roof. Then according to the geology and the ore characteristic, the three dimension FEM mechanical model is built in Tongkeng Mine, the laws of the tensile stress are analyzed to the space and the time in the roof with the mining, then it is rational design to the mine step and time of the handing the roof.

  7. Chemical composition of water from roofs in Gdansk, Poland

    Energy Technology Data Exchange (ETDEWEB)

    Tsakovski, Stefan, E-mail: stsakovski@chem.uni-sofia.b [Chair of Physical Chemistry, Faculty of Chemistry, University of Sofia, J Bourchier Blvd. 1, 1164 Sofia (Bulgaria); Tobiszewski, Marek [Department of Analytical Chemistry, Chemical Faculty, Gdansk University of Technology (GUT), 11/12 G. Narutowicza St., 80-952 Gdansk (Poland); Simeonov, Vasil, E-mail: vsimeonov@chem.uni-sofia.b [Chair of Analytical Chemistry, Faculty of Chemistry, University of Sofia, 1164 Sofia (Bulgaria); Polkowska, Zaneta [Department of Analytical Chemistry, Chemical Faculty, Gdansk University of Technology (GUT), 11/12 G. Narutowicza St., 80-952 Gdansk (Poland); Namiesnik, Jacek, E-mail: chemanal@pg.gda.p [Department of Analytical Chemistry, Chemical Faculty, Gdansk University of Technology (GUT), 11/12 G. Narutowicza St., 80-952 Gdansk (Poland)

    2010-01-15

    This study deals with the assessment of roof runoff waters from the region of Gdansk collected during the winter season (2007/2008). The chemical analysis includes 16 chemical variables: major ions, PAHs and PCBs measured at 3 sampling sites for 6-14 rain events. Although the data set is of limited volume the statistical data treatment using self-organizing maps (SOM) reveals the main factors controlling roof runoff water quality even for a data set with small dimension. This effort for explanation of the identified factors by the possible emission sources of the urban environment and air-particulate formation seems to be very reliable. Additionally to the roof runoff water quality factors the rain events patterns are found: 'background' group of events and groups formally named 'PAHs', 'PCBs' and 'air-borne particles' - dominated events. The SOM classification results give an opportunity to uncover the role of roof 'impact' on the runoff waters. Rain runoff water quality is described by four latent factors and the 'roof' impact is uncovered. - Identification of the urban roof runoff water quality factors and 'roof' impact by self-organizing map classification.

  8. Multi functional roof structures of the energy efficient buildings

    Directory of Open Access Journals (Sweden)

    Krstić Aleksandra

    2006-01-01

    Full Text Available Modern architectural concepts, which are based on rational energy consumption of buildings and the use of solar energy as a renewable energy source, give the new and significant role to the roofs that become multifunctional structures. Various energy efficient roof structures and elements, beside the role of protection, provide thermal and electric energy supply, natural ventilation and cooling of a building, natural lighting of the indoor space sunbeam protection, water supply for technical use, thus according to the above mentioned functions, classification and analysis of such roof structures and elements are made in this paper. The search for new architectural values and optimization in total energy balance of a building or the likewise for the urban complex, gave to roofs the role of "climatic membranes". Contemporary roof forms and materials clearly exemplify their multifunctional features. There are numerous possibilities to achieve the new and attractive roof design which broadens to the whole construction. With such inducement, this paper principally analyze the configuration characteristics of the energy efficient roof structures and elements, as well as the visual effects that may be achieved by their application.

  9. Advanced exterior sensor project : final report, September 2004.

    Energy Technology Data Exchange (ETDEWEB)

    Ashby, M. Rodema

    2004-12-01

    This report (1) summarizes the overall design of the Advanced Exterior Sensor (AES) system to include detailed descriptions of system components, (2) describes the work accomplished throughout FY04 to evaluate the current health of the original prototype and to return it to operation, (3) describes the status of the AES and the AES project as of September 2004, and (4) details activities planned to complete modernization of the system to include development and testing of the second-generation AES prototype.

  10. GATEWAY Demonstrations: Exterior LED Lighting Projects at Princeton University

    Energy Technology Data Exchange (ETDEWEB)

    Davis, Robert G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Evans, WIlliam E. [Princeton Univ., NJ (United States); Murphy, Arthur [Princeton Univ., NJ (United States); Perrin, Tess [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-10-30

    This report focuses on four exterior solid-state lighting projects that have been completed at Princeton since 2008, when the University adopted a comprehensive sustainability plan. Through these initial projects – which include a parking garage, a pedestrian path, and two parking lot installations – the school’s facilities engineering staff learned important lessons about SSL technology and gained experience in dealing with the rapidly changing landscape of lighting manufacturers and their suppliers.

  11. Spray Foam Exterior Insulation with Stand-Off Furring

    Energy Technology Data Exchange (ETDEWEB)

    Herk, Anatasia [IBACOS, Inc., Pittsburgh, PA (United States); Baker, Richard [IBACOS, Inc., Pittsburgh, PA (United States); Prahl, Duncan [IBACOS, Inc., Pittsburgh, PA (United States)

    2014-03-01

    IBACOS, in collaboration with GreenHomes America, was contracted by the New York State Energy Research and Development Authority to research exterior wall insulation solutions. This research investigated cost-effective deep energy retrofit (DER) solutions for improving the building shell exterior while achieving a cost-reduction goal, including reduced labor costs to reach a 50/50 split between material and labor. The strategies included exterior wall insulation plus energy upgrades as needed in the attic, mechanical and ventilation systems, and basement band joist, walls, and floors. The work can be integrated with other home improvements such as siding or window replacement. This strategy minimizes physical connections to existing wall studs, encapsulates existing siding materials (including lead paint) with spray foam, and creates a vented rain screen assembly to promote drying. GreenHomes America applied construction details created by IBACOS to a test home. 2x4 framing members were attached to the wall at band joists and top plates using "L" clips, with spray foam insulating the wall after framing was installed. Windows were installed simultaneously with the framing, including extension jambs. The use of clips in specific areas provided the best strength potential, and "picture framing" the spray foam held the 2x4s in place. Short-term testing was performed at this house, with monitoring equipment installed for long-term testing. Testing measurements will be provided in a later report, as well as utility impact (before and after), costs (labor and materials), construction time, standard specifications, and analysis for the exterior wall insulation strategy.

  12. Spray Foam Exterior Insulation with Stand-Off Furring

    Energy Technology Data Exchange (ETDEWEB)

    Herk, A.; Baker, R.; Prahl, D.

    2014-03-01

    IBACOS, in collaboration with GreenHomes America, was contracted by the New York State Energy Research and Development Authority to research exterior wall insulation solutions. This research investigated cost-effective deep energy retrofit (DER) solutions for improving the building shell exterior while achieving a cost-reduction goal, including reduced labor costs to reach a 50/50 split between material and labor. The strategies included exterior wall insulation plus energy upgrades as needed in the attic, mechanical and ventilation systems, and basement band joist, walls, and floors. The work can be integrated with other home improvements such as siding or window replacement. This strategy minimizes physical connections to existing wall studs, encapsulates existing siding materials (including lead paint) with spray foam, and creates a vented rain screen assembly to promote drying. GreenHomes America applied construction details created by IBACOS to a test home. 2x4 framing members were attached to the wall at band joists and top plates using 'L' clips, with spray foam insulating the wall after framing was installed. Windows were installed simultaneously with the framing, including extension jambs. The use of clips in specific areas provided the best strength potential, and 'picture framing' the spray foam held the 2x4s in place. Short-term testing was performed at this house, with monitoring equipment installed for long-term testing. Testing measurements will be provided in a later report, as well as utility impact (before and after), costs (labor and materials), construction time, standard specifications, and analysis for the exterior wall insulation strategy.

  13. Rainwater runoff retention on an aged intensive green roof.

    Science.gov (United States)

    Speak, A F; Rothwell, J J; Lindley, S J; Smith, C L

    2013-09-01

    Urban areas are characterised by large proportions of impervious surfaces which increases rainwater runoff and the potential for surface water flooding. Increased precipitation is predicted under current climate change projections, which will put further pressure on urban populations and infrastructure. Roof greening can be used within flood mitigation schemes to restore the urban hydrological balance of cities. Intensive green roofs, with their deeper substrates and higher plant biomass, are able to retain greater quantities of runoff, and there is a need for more studies on this less common type of green roof which also investigate the effect of factors such as age and vegetation composition. Runoff quantities from an aged intensive green roof in Manchester, UK, were analysed for 69 rainfall events, and compared to those on an adjacent paved roof. Average retention was 65.7% on the green roof and 33.6% on the bare roof. A comprehensive soil classification revealed the substrate, a mineral soil, to be in good general condition and also high in organic matter content which can increase the water holding capacity of soils. Large variation in the retention data made the use of predictive regression models unfeasible. This variation arose from complex interactions between Antecedant Dry Weather Period (ADWP), season, monthly weather trends, and rainfall duration, quantity and peak intensity. However, significantly lower retention was seen for high rainfall events, and in autumn, which had above average rainfall. The study period only covers one unusually wet year, so a longer study may uncover relationships to factors which can be applied to intensive roofs elsewhere. Annual rainfall retention for Manchester city centre could be increased by 2.3% by a 10% increase in intensive green roof construction. The results of this study will be of particular interest to practitioners implementing greenspace adaptation in temperate and cool maritime climates.

  14. Cool roofs as an energy conservation measure for federal buildings

    Energy Technology Data Exchange (ETDEWEB)

    Taha, Haider; Akbari, Hashem

    2003-04-07

    We have developed initial estimates of the potential benefits of cool roofs on federal buildings and facilities (building scale) as well as extrapolated the results to all national facilities under the administration of the Federal Energy Management Program (FEMP). In addition, a spreadsheet ''calculator'' is devised to help FEMP estimate potential energy and cost savings of cool roof projects. Based on calculations for an average insulation level of R-11 for roofs, it is estimated that nationwide annual savings in energy costs will amount to $16M and $32M for two scenarios of increased roof albedo (moderate and high increases), respectively. These savings, corresponding to about 3.8 percent and 7.5 percent of the base energy costs for FEMP facilities, include the increased heating energy use (penalties) in winter. To keep the cost of conserved energy (CCE) under $0.08 kWh-1 as a nationwide average, the calculations suggest that the incremental cost for cool roofs should not exceed $0.06 ft-2, assuming that cool roofs have the same life span as their non-cool counterparts. However, cool roofs usually have extended life spans, e.g., 15-30 years versus 10 years for conventional roofs, and if the costs of re-roofing are also factored in, the cutoff incremental cost to keep CCE under $0.08 kWh-1 can be much higher. In between these two ends, there is of course a range of various combinations and options.

  15. Expert Meeting Report: Cladding Attachment Over Exterior Insulation (BSC Report)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-10-01

    The addition of insulation to the exterior of buildings is an effective means of increasing the thermal resistance of both wood framed walls as well as mass masonry wall assemblies. The location of the insulation to the exterior of the structure has many direct benefits including better effective R-value from reduced thermal bridging, better condensation resistance, reduced thermal stress on the structure, as well as other commonly associated improvements such as increased air tightness and improved water management (Hutcheon 1964, Lstiburek 2007). The intent of the meeting was to review the current state of industry knowledge regarding cladding attachment over exterior insulation with a specific focus on: 1. Gravity load resistance, 2. Wind load resistance. The presentations explore these topics from an engineering design, laboratory testing, field monitoring, as well as practical construction perspective. By bringing various groups together (who have been conduction research or have experience in this area), a more holistic review of the design limits and current code language proposals can be completed and additional gaps identified. The results of which will help inform design standards and criteria.

  16. Expert Meeting Report: Cladding Attachment Over Exterior Insulation

    Energy Technology Data Exchange (ETDEWEB)

    Baker, P. [Building Science Corporation, Somerville, MA (United States)

    2013-10-01

    The addition of insulation to the exterior of buildings is an effective means of increasing the thermal resistance of both wood framed walls as well as mass masonry wall assemblies. The location of the insulation to the exterior of the structure has many direct benefits including better effective R-value from reduced thermal bridging, better condensation resistance, reduced thermal stress on thestructure, as well as other commonly associated improvements such as increased air tightness and improved water management (Hutcheon 1964, Lstiburek 2007). The intent of the meeting was to review the current state of industry knowledge regarding cladding attachment over exterior insulation with a specific focus on: 1. Gravity load resistance, 2. Wind load resistance. The presentations explorethese topics from an engineering design, laboratory testing, field monitoring, as well as practical construction perspective. By bringing various groups together (who have been conduction research or have experience in this area), a more holistic review of the design limits and current code language proposals can be completed and additional gaps identified. The results of which will help informdesign standards and criteria.

  17. Limit and end functors of dynamical systems via exterior spaces

    CERN Document Server

    Calcines, J M Garcia; Rodriguez, M Teresa Rivas

    2012-01-01

    In this paper we analyze some applications of the category of exterior spaces to the study of dynamical systems (flows). We study the notion of an absorbing open subset of a dynamical system; i.e., an open subset that contains the "future part" of all the trajectories. The family of all absorbing open subsets is a quasi-filter which gives the structure of an exterior space to the flow. The limit space and end space of an exterior space is used to construct the limit spaces and end spaces of a dynamical system. On the one hand, for a dynamical system two limits spaces $L^{\\r}(X)$ and $\\bar L^{\\r}(X)$ are constructed and their relations with the subflows of periodic, Poisson stable points and $\\Omega^{\\r}$-limits of $X$ are analyzed. On the other hand, different end spaces are also associated to a dynamical system having the property that any positive semi-trajectory has an end point in these end spaces. This type of construction permits us to consider the subflow containing all trajectories finishing at an end...

  18. An environmental cost-benefit analysis of alternative green roofing strategies

    Science.gov (United States)

    Richardson, M.; William, R. K.; Goodwell, A. E.; Le, P. V.; Kumar, P.; Stillwell, A. S.

    2016-12-01

    Green roofs and cool roofs are alternative roofing strategies that mitigate urban heat island effects and improve building energy performance. Green roofs consist of soil and vegetation layers that provide runoff reduction, thermal insulation, and potential natural habitat, but can require regular maintenance. Cool roofs involve a reflective layer that reflects more sunlight than traditional roofing materials, but require additional insulation during winter months. This study evaluates several roofing strategies in terms of energy performance, urban heat island mitigation, water consumption, and economic cost. We use MLCan, a multi-layer canopy model, to simulate irrigated and non-irrigated green roof cases with shallow and deep soil depths during the spring and early summer of 2012, a drought period in central Illinois. Due to the dry conditions studied, periodic irrigation is implemented in the model to evaluate its effect on evapotranspiration. We simulate traditional and cool roof scenarios by altering surface albedo and omitting vegetation and soil layers. We find that both green roofs and cool roofs significantly reduce surface temperature compared to the traditional roof simulation. Cool roof temperatures always remain below air temperature and, similar to traditional roofs, require low maintenance. Green roofs remain close to air temperature and also provide thermal insulation, runoff reduction, and carbon uptake, but might require irrigation during dry periods. Due to the longer lifetime of a green roof compared to cool and traditional roofs, we find that green roofs realize the highest long term cost savings under simulated conditions. However, using longer-life traditional roof materials (which have a higher upfront cost) can help decrease this price differential, making cool roofs the most affordable option due to the higher maintenance costs associated with green roofs

  19. The effects of green roofs in a sub-tropical system

    Energy Technology Data Exchange (ETDEWEB)

    Simmons, M. [Austin Univ., Austin, TX (United States). Lady Bird Johnson Wildflower Center; Gardiner, B. [Austech Roof Consultants Inc., Austin, TX (United States)

    2007-07-01

    The building and environmental benefits of green roofs in non-temperate, or subtropical systems were discussed. Since there are greater climatic extremes in such systems, green roofs may offer more benefits. Most green roof research has focused on the use of succulent plants due to their low water demand and slow growth rates. The Lady Bird Johnson Wildflower Center and the Roof Consultants Institute Foundation are conducting joint research project to assess the suitability of native vegetation for use on extensive green roofs in central Texas. The project examined the effects of green roofing in a subtropical climate and the thermal properties of buildings, stormwater runoff rates, water quality, and irrigation requirements. Stormwater retention capacity of green roofs and water quality of stormwater runoff was compared to conventional roofs. The growing media that are most successful for this particular ecoregion was also identified. The focus on native plants in this study identified the characteristics of climatic adaptation, which may help to reduce total water and nutrient demand, and avoid problems associated with the introduction of potentially invasive species. The study compared performance of 6 types of green roofs and two types of traditional roof materials using simulated roof platforms. During the hottest days in August, roof membrane temperatures on the green roofs were 10 degrees C cooler than white roofs and 40 degrees C cooler than conventional black roofs. It was concluded that the temperature and water quantity characteristics of green roofs are advantageous in subtropical climates. 4 refs., 1 tab., 4 figs.

  20. Specifying, Installing and Maintaining Built-Up and Modified Bitumen Roofing Systems.

    Science.gov (United States)

    Hobson, Joseph W.

    2000-01-01

    Examines built-up, modified bitumen, and hybrid combinations of the two roofing systems and offers advise on how to assure high- quality performance and durability when using them. Included is a glossary of commercial roofing terms and asphalt roofing resources to aid in making decisions on roofing and systems product selection. (GR)

  1. Cool Roofs to Save Money and Delay Global Warming

    Science.gov (United States)

    Rosenfeld, Arthur

    2006-04-01

    White roofs, and now cool-colored roofs, with a high reflectivity or `albedo' have a long history (best known around the Mediterranean) of keeping buildings and cities cool. In modern times, cool roofs have been shown to reduce air conditioning (a-c) demand and slow the formation of ozone (smog). Studies establishing a typical 10% reduction in a-c demand and electricity savings due to white roofs in California (CA) resulted in the 2005 CA new building energy efficiency standard prescribing that low-slope roofs be white, but exempting sloping roofs for aesthetic reasons. The advent (thanks to physicists' efforts) of inexpensive colored pigments with high albedo has led to 2008 CA standards requiring that even sloping roofs be cool. Here, I show that cooling the planet by reducing urban albedo through white and other cool roofs is a direct effect, much larger and immediate than the 2nd-order cooling from reduced CO2 from reduced a-c use. I then investigate widespread deployment of cool roof in major tropical and temperate cities, which cover 2% of global land area and have a proportionately higher albedo impact due to lower latitude. Here, cool roofs and cooler pavements can raise urban albedo by 10%. This directly drops the global average temperature by ˜0.05 /deg C. Though small compared to a likely 3 /deg C rise by 2060, an immediate drop of 0.05 /deg C represents a reprieve in global warming of 1 year, and represents avoiding a year's current annual world emissions of CO2, i.e. 25 GT(CO2). At a trading price of 25/tCO2, this is worth ˜625B. Cooling the planet also could save annually hundreds of billions on a-c electric bills. Finally I suggest policies to increase cool roof deployment, for example, developed world Kyoto signatories could use its CDM (Clean Development Mechanism) for cool roof programs in developing countries.

  2. Automatic Generation of 3D Building Models with Multiple Roofs

    Institute of Scientific and Technical Information of China (English)

    Kenichi Sugihara; Yoshitugu Hayashi

    2008-01-01

    Based on building footprints (building polygons) on digital maps, we are proposing the GIS and CG integrated system that automatically generates 3D building models with multiple roofs. Most building polygons' edges meet at right angles (orthogonal polygon). The integrated system partitions orthogonal building polygons into a set of rectangles and places rectangular roofs and box-shaped building bodies on these rectangles. In order to partition an orthogonal polygon, we proposed a useful polygon expression in deciding from which vertex a dividing line is drawn. In this paper, we propose a new scheme for partitioning building polygons and show the process of creating 3D roof models.

  3. The impact of roofing material on building energy performance

    Science.gov (United States)

    Badiee, Ali

    The last decade has seen an increase in the efficient use of energy sources such as water, electricity, and natural gas as well as a variety of roofing materials, in the heating and cooling of both residential and commercial infrastructure. Oil costs, coal and natural gas prices remain high and unstable. All of these instabilities and increased costs have resulted in higher heating and cooling costs, and engineers are making an effort to keep them under control by using energy efficient building materials. The building envelope (that which separates the indoor and outdoor environments of a building) plays a significant role in the rate of building energy consumption. An appropriate architectural design of a building envelope can considerably lower the energy consumption during hot summers and cold winters, resulting in reduced HVAC loads. Several building components (walls, roofs, fenestration, foundations, thermal insulation, external shading devices, thermal mass, etc.) make up this essential part of a building. However, thermal insulation of a building's rooftop is the most essential part of a building envelope in that it reduces the incoming "heat flux" (defined as the amount of heat transferred per unit area per unit time from or to a surface) (Sadineni et al., 2011). Moreover, more than 60% of heat transfer occurs through the roof regardless of weather, since a roof is often the building surface that receives the largest amount of solar radiation per square annually (Suman, and Srivastava, 2009). Hence, an argument can be made that the emphasis on building energy efficiency has influenced roofing manufacturing more than any other building envelope component. This research project will address roofing energy performance as the source of nearly 60% of the building heat transfer (Suman, and Srivastava, 2009). We will also rank different roofing materials in terms of their energy performance. Other parts of the building envelope such as walls, foundation

  4. Can green roof act as a sink for contaminants? A methodological study to evaluate runoff quality from green roofs.

    Science.gov (United States)

    Vijayaraghavan, K; Joshi, Umid Man

    2014-11-01

    The present study examines whether green roofs act as a sink or source of contaminants based on various physico-chemical parameters (pH, conductivity and total dissolved solids) and metals (Na, K, Ca, Mg, Al, Fe, Cr, Cu, Ni, Zn, Cd and Pb). The performance of green roof substrate prepared using perlite, vermiculite, sand, crushed brick, and coco-peat, was compared with local garden soil based on improvement of runoff quality. Portulaca grandiflora was used as green roof vegetation. Four different green roof configurations, with vegetated and non-vegetated systems, were examined for several artificial rain events (un-spiked and metal-spiked). In general, the vegetated green roof assemblies generated better-quality runoff with less conductivity and total metal ion concentration compared to un-vegetated assemblies. Of the different green roof configurations examined, P. grandiflora planted on green roof substrate acted as sink for various metals and showed the potential to generate better runoff.

  5. Detecting Signage and Doors for Blind Navigation and Wayfinding.

    Science.gov (United States)

    Wang, Shuihua; Yang, Xiaodong; Tian, Yingli

    2013-07-01

    Signage plays a very important role to find destinations in applications of navigation and wayfinding. In this paper, we propose a novel framework to detect doors and signage to help blind people accessing unfamiliar indoor environments. In order to eliminate the interference information and improve the accuracy of signage detection, we first extract the attended areas by using a saliency map. Then the signage is detected in the attended areas by using a bipartite graph matching. The proposed method can handle multiple signage detection. Furthermore, in order to provide more information for blind users to access the area associated with the detected signage, we develop a robust method to detect doors based on a geometric door frame model which is independent to door appearances. Experimental results on our collected datasets of indoor signage and doors demonstrate the effectiveness and efficiency of our proposed method.

  6. Roof structure theory and support resistance determination of longwall face in shallow seam

    Institute of Scientific and Technical Information of China (English)

    HUANG Qing-xiang(黄庆享)

    2003-01-01

    This paper presents the structure models founded in shallow seam, the roof asymmetry arch with three articulations in roof first weighting and the step voussoir beam in roof periodic weighting. These structure models are differ from classic theory, it establishes the new roof control theory of instability structure roof, especially in shallow seam. Based on the new roof structure theory, the support working state of "given sliding load" is put forward, and the factor of load transmitting is introduced to determine the load on roof structure. Therefore, the proper and accurate calculating methods of support resistance are established. Based on this, the dynamic structure theory in shallow seam could be predicted.

  7. ['Door de beugel': resorption at dental elements].

    Science.gov (United States)

    Leunisse, M; Barendrecht, D S

    2015-09-01

    A twenty-year-old man was referred to an orthodontist for orthodontic re-treatment of dental element 32 by his dentist and a periodontist. At the buccal surface of the dental element a significant gingival resorption had occurred and the root of the element was located outside of the processus alveolaris buccally. This case will be presented at the thematic tour 'Door de beugel: team up' on 27 October 2015, which is organised by the Nederlandse Vereniging van Tandartsen (Dutch Dentists' Society) and will be held at 4 different locations in the Netherlands. Readers of the Nederlands Tijdschrift voor Tandheelkunde get an exclusive preview of the case. The treatment of choice will be published in the December 2015 issue.

  8. Hazard Management with DOORS: Rail Infrastructure Projects

    Science.gov (United States)

    Hughes, Dave; Saeed, Amer

    LOI is a major rail infrastructure project that will contribute to a modernised transport system in time for the 2012 Olympic Games. A review of the procedures and tool infrastructure was conducted in early 2006, coinciding with a planned move to main works. A hazard log support tool was needed to provide: an automatic audit trial, version control and support collaborative working. A DOORS based Hazard Log (DHL) was selected as the Tool Strategy. A systematic approach was followed for the development of DHL, after a series of tests and acceptance gateways, DHL was handed over to the project in autumn 2006. The first few months were used for operational trials and he Hazard Management rocedure was modified to be a hybrid approach that used the strengths of DHL and Excel. The user experience in the deployment of DHL is summarised and directions for future improvement identified.

  9. Bidding to give in the field: door-to-door fundraisers had it right from the start

    NARCIS (Netherlands)

    Onderstal, S.; Schram, A.J.H.C.; Soetevent, A.R.

    2011-01-01

    In a door-to-door fundraising field experiment, we study the impact of fundraising mechanisms on charitable giving. We approached about 4500 households, each participating in either an all-pay auction, a lottery, a non-anonymous voluntary contribution mechanism (VCM), or an anonymous VCM. In contras

  10. Is Door-to-Door Canvassing Effective in Europe? Evidence from a Meta-study across Six European Countries

    DEFF Research Database (Denmark)

    Bhatti, Yosef; Dahlgaard, Jens Olav; Hansen, Jonas Hedegaard

    2016-01-01

    A vast amount of experimental evidence suggests that get-out-the-vote encouragements delivered through door-to-door canvassing have large effects on turnout. Most of the existing studies have been conducted in the United States, and are inspiring European mobilization campaigns. This article expl...

  11. Technical considerations in green roof retrofit for stormwater attenuation in the central business district

    OpenAIRE

    Wilkinson, S.; Lamond, J.; Proverbs, D.; Sharman, L.; Heller, A; Manion, J.

    2015-01-01

    Purpose: The key aspects that built environment professionals need to consider when evaluating roofs for the purpose of green roof retrofit and also when assessing green roofs for technical due diligence purposes are outlined. Although green or sod roofs have been built over many centuries, contemporary roofs adopt new approaches and technologies. The paper aims to discuss these issues. \\ud \\ud Design/methodology/approach: A mixed methods design based on a systematic review of relevant litera...

  12. The Feasibility of Installing and Monitoring an Extensive Green Roof at Purdue University

    OpenAIRE

    2007-01-01

    The Boiler Green Initiative (BGI) is a student-run organization working to improve environmental sustainability at the Purdue University West Lafayette campus. A main goal of BGI's is to install a green roof on an existing building on campus that is being replaced. We discuss the benefits of green roofs, the feasibility of having one installed on the Armory's roof and the various monitoring options we have researched. Flat roofs are especially amenable to the green roof system, so a building ...

  13. 框架式结构汽车门锁系统布置匹配方法分析研究%Analysis and Research on Layout and Matching for the Auto Door Lock System of Frame Structure

    Institute of Scientific and Technical Information of China (English)

    宋策; 丁祎; 臧宏

    2014-01-01

    以某款轿车的汽车门锁系统布置匹配为例,论述了汽车门锁在车身中的位置、汽车门锁与铰链轴线的位置关系,以及汽车门锁与外把手的位置关系。并总结出一种新的汽车门锁系统布置匹配方法。通过CAE分析及DMU运动分析验证了该布置方法的有效性。对样车进行耐久性试验结果可知,采用该方法布置匹配的汽车门锁系统全部零件功能正常,仅锁扣啮合处的电镀层出现轻微磨损,但符合设计要求。%Taking the auto door lock system layout matching of a car as example, this paper discusses the location of door lock in car vody, relationship vetween door lock and hinge axes, as well as the relationship vetween door lock and exterior door handle. This paper also sums up a new layout and matching method for the door lock system, and proves this layout method with CAE analysis and DMU motion analysis. The prototype duravility test results show that all the components of the door lock system arranged with this method function properly, only the galvanized coating at the lock latch engagement wears slightly, however it still comply with design requirement.

  14. Modeling a Hydrologically Optimal Green Roof Media Mixture

    Science.gov (United States)

    Background/Questions/MethodsA key environmental concern in managing urban ecosystems is controlling stormwater runoff to ameliorate pollution problems and sewage overflows. Vegetated green roofs have become an important green infrastructure tool to collect, store, and gradually r...

  15. Roof Isolation System - A Vibration Absorber for Buildings

    Institute of Scientific and Technical Information of China (English)

    田志昌; 钱稼茹

    2001-01-01

    A roof isolation system is proposed to reduce the dynamic response of buildings to earthquake excitations. In the system, frictional materials are inserted between the roof slab and the beams that support the slab. The roof slab and the beams are connected by springs. The optimum stiffness of the system is determined to minimize the seismic response of the buildings. A comparative study of the responses of an eight-story frame structure with and without the proposed system to ground motions was carried out to assess the system effectiveness. The study showed that the system energy dissipation capacity is nonlinear. The effectiveness of the system is related to the frequency and the acceleration of the ground motion. The system reduces the maximum lateral displacement response and the maximum inter-story drift response of the building by as much as 45% except for the roof.

  16. Experimental measurements and numerical modelling of a green roof

    Energy Technology Data Exchange (ETDEWEB)

    Lazzarin, Renato M.; Castellotti, Francesco; Busato, Filippo [Padova Univ., Dept. of Management and Engineering, Vicenza (Italy)

    2005-12-15

    Green roof utilisation has been known since ancient times both in hot and cold climates. Nowadays, it has been reconsidered at issue of energy saving and pollution reduction. In this paper, some measurement sessions on a green roof installed by the Vicenza Hospital are described. A data logging system with temperature, humidity, rainfall, radiation, etc. sensors surveyed both the parameters related to the green roof and to the rooms underneath. The aim is to evaluate the passive cooling, stressing the evapotranspiration role in summer time. Furthermore, the enhanced insulating properties have been tested during winter time. A predictive numerical model has been developed in a building simulation software (TRNSYS) to calculate thermal and energy performances of a building with a green roof, varying the meteorological dataset for a specific geographic zone. (Author)

  17. Variability of Rain Water Quality due to Roof Characteristics | Utsev ...

    African Journals Online (AJOL)

    Variability of Rain Water Quality due to Roof Characteristics. ... is receiving increased attention worldwide as an alternative source of drinking water. ... as grey water for domestic purposes but requires treatment to be used as drinking water.

  18. MODELING OF STORM WATER RUNOFF FROM GREEN ROOFS

    Directory of Open Access Journals (Sweden)

    Ewa Burszta-Adamiak

    2014-10-01

    Full Text Available Apart from direct measurements, modelling of runoff from green roofs is valuable source of information about effectiveness of this type of structure from hydrological point of view. Among different type of models, the most frequently used are numerical models. They allow to assess the impact of green roofs on decrease and attenuation of runoff, reduction of peak runoff and value of water retention. This paper presents preliminary results of research on computing the rate of runoff from green roofs using GARDENIA model. The analysis has been carried out for selected rainfall events registered during measuring campaign on pilot-scale green roofs. Obtained results are promising and show good fit between observed and simulated runoff.

  19. High Alumina Refractory Bricks for Electric Arc Furnace Roofs

    Institute of Scientific and Technical Information of China (English)

    2007-01-01

    @@ 1 Scope This standard specifies the sort, technical requirement, test method, inspection rules, marking, packing, transportation, storage and quality certification of high alumina refractory bricks for electric arc furnace roofs.

  20. Green roofs: A possible best management practice for enhancing ...

    African Journals Online (AJOL)

    ... roofs: A possible best management practice for enhancing the environmental quality ... erodes the natural ability of the locale to perform its ecosystem services. ... structural components, formulation of guidelines for the industry, government ...

  1. Home advantage in retractable-roof baseball stadia.

    Science.gov (United States)

    Romanowich, Paul

    2012-10-01

    This study examined whether the home advantage varies for open-air, domed, or retractable-roof baseball stadia, and whether having the roof open or closed affects the home advantage in retractable-roof baseball stadia. Data from Major League Baseball (MLB) games played between 2001 and 2009 were analyzed for whether or not the presence of a home-advantage was dependent on the type of home stadium used. Home advantage was robust for all three types of stadia. A significant effect of stadium type on home advantage was found, with a greater home advantage for teams playing home games in domed stadia relative to open-air stadia, replicating a previous study. There was a greater home advantage for teams playing home games in domed stadia relative to retractable-roof stadia. No other differences in the home advantage were found; results are discussed in terms of familiarity with the facility.

  2. Diaphragm Effect of Steel Space Roof Systems in Hall Structures

    Directory of Open Access Journals (Sweden)

    Mehmet FENKLİ

    2015-09-01

    Full Text Available Hall structures have been used widely for different purposes. They have are reinforced concrete frames and shear wall with steel space roof systems. Earthquake response of hall structures is different from building type structures. One of the most critical nodes is diaphragm effect of steel space roof on earthquake response of hall structures. Diaphragm effect is depending on lateral stiffness capacity of steel space roof system. Lateral stiffness of steel space roof system is related to modulation geometry, support conditions, selected sections and system geometry. In current paper, three representative models which are commonly used in Turkey were taken in to account for investigation. Results of numerical tests were present comparatively

  3. How EPA's Asbestos Regulations Apply to Roofing Materials

    Science.gov (United States)

    Guidance Manual and letters that clarify the applicability of the asbestos National Emissions Standard for Hazardous Air Pollutants (NESHAP) to the removal of asbestos-containing roofing material including tiles, and piping during demolition

  4. Summer Thermal Performance of Ventilated Roofs with Tiled Coverings

    Science.gov (United States)

    Bortoloni, M.; Bottarelli, M.; Piva, S.

    2017-01-01

    The thermal performance of a ventilated pitched roof with tiled coverings is analysed and compared with unventilated roofs. The analysis is carried out by means of a finite element numerical code, by solving both the fluid and thermal problems in steady-state. A whole one-floor building with a pitched roof is schematized as a 2D computational domain including the air-permeability of tiled covering. Realistic data sets for wind, temperature and solar radiation are used to simulate summer conditions at different times of the day. The results demonstrate that the batten space in pitched roofs is an effective solution for reducing the solar heat gain in summer and thus for achieving better indoor comfort conditions. The efficiency of the ventilation is strictly linked to the external wind conditions and to buoyancy forces occurring due to the heating of the tiles.

  5. Analysis of mechanism of shock bump due to roof fall

    Institute of Scientific and Technical Information of China (English)

    GU Xin-jian; LI Jian-xiong

    2004-01-01

    According to the characteristics of the shock bump due to roof fall, a simple mechanics model has been established by applying the catastrophic theory and the law of energy conservation. The author suggests that the shock bump may be induced by the sudden energy release in the roof falling after underground mineral extractions, and through the systematic analysis of actual examples on site, the empirical formulae for the roof falling and energy release are derived, which would provide a new way for the study of the origin and mechanism of mine tremor due to fallen-in roof structure. It is of a great importance to enrich the shock bump theory and production safety in mine.

  6. Application of solar roof shallow pool at individual residental buildings

    Directory of Open Access Journals (Sweden)

    Gavrilović Dragan J.

    2011-01-01

    Full Text Available The paper discusses the possibility of applying shallow roof pools of water on the basis of passive solar water capture functioning as thermal batteries and thermal "regulators" in a "hot - cold" mode with individual residential buildings. With this application, the utilization of the existing functionality of the building roof area would improve and open up the possibility of achieving better overall bio-climate individual object. By using this system, a flat roof impassable "terrace" takes on a new, additional energy function, which proves the ability to reduce overall energy consumption of total conventional seasonal heating and cooling consumption of a building. Supporting of this intention, the paper gives a variant solution of an easily prefabricated reinforced concrete roof system of shallow water pool that works on the principle of passive solar energy capture.

  7. Soil-water fluxes modelling in a green roof

    Science.gov (United States)

    Lamera, Carlotta; Rulli, Maria Cristina; Becciu, Gianfranco; Rosso, Renzo

    2014-05-01

    Green roofs differ from a natural environment as they are on top of a building and are not connected to the natural ground; therefore it is critical that soils can drain and retain water simultaneously and that they work even in very shallow systems. The soil or growing medium used for green roofs is specifically engineered to provide the vegetation with nutrients, discharging any excess water into the drainage layer, and releasing stored water back into the substrate. In this way, medium depth and porosity plays an important role in stormwater retention and plant growth in a green roof. Due to the lack of a good understanding about the hydraulic efficiency of each green roof's layer in rainwater management, a detailed analysis of the hydrological dynamics, connected with the green roof technical design is essential in order to obtain a full characterization of the hydrologic behavior of a green roof system and its effects on the urban water cycle components. The purpose of this research is analyzing the soil-water dynamics through the different components of a green roof and modeling these processes though a detailed but clear subsurface hydrology module, based on green roof vertical soil water movement reproduction, in relation to climate forcing, basic technology components and geometric characteristics of green roof systems (thickness of the stratigraphy, soil layers and materials, vegetation typology and density). A multi-layer bucket model has been applied to examine the hydrological response of the green roof system under a temperate maritime climate, by varying the physical and geometric parameters that characterize the different components of the vegetated cover. Following a stage of validation and calibration, results confirm the suitability of the model to describe the hydrologic response of the green roof during the observed rainfall events: the discharge hydrograph profile, volume and timing, predicted by the model, matched experimental measurements

  8. Plant species richness enhances nitrogen retention in green roof plots.

    Science.gov (United States)

    Johnson, Catherine; Schweinhart, Shelbye; Buffam, Ishi

    2016-10-01

    Vegetated (green) roofs have become common in many cities and are projected to continue to increase in coverage, but little is known about the ecological properties of these engineered ecosystems. In this study, we tested the biodiversity-ecosystem function hypothesis using commercially available green roof trays as replicated plots with varying levels of plant species richness (0, 1, 3, or 6 common green roof species per plot, using plants with different functional characteristics). We estimated accumulated plant biomass near the peak of the first full growing season (July 2013) and measured runoff volume after nearly every rain event from September 2012 to September 2013 (33 events) and runoff fluxes of inorganic nutrients ammonium, nitrate, and phosphate from a subset of 10 events. We found that (1) total plant biomass increased with increasing species richness, (2) green roof plots were effective at reducing storm runoff, with vegetation increasing water retention more than soil-like substrate alone, but there was no significant effect of plant species identity or richness on runoff volume, (3) green roof substrate was a significant source of phosphate, regardless of presence/absence of plants, and (4) dissolved inorganic nitrogen (DIN = nitrate + ammonium) runoff fluxes were different among plant species and decreased significantly with increasing plant species richness. The variation in N retention was positively related to variation in plant biomass. Notably, the increased biomass and N retention with species richness in this engineered ecosystem are similar to patterns observed in published studies from grasslands and other well-studied ecosystems. We suggest that more diverse plantings on vegetated roofs may enhance the retention capacity for reactive nitrogen. This is of importance for the sustained health of vegetated roof ecosystems, which over time often experience nitrogen limitation, and is also relevant for water quality in receiving waters

  9. MODELING OF STORM WATER RUNOFF FROM GREEN ROOFS

    OpenAIRE

    Ewa Burszta-Adamiak; Wiesław Fiałkiewicz

    2014-01-01

    Apart from direct measurements, modelling of runoff from green roofs is valuable source of information about effectiveness of this type of structure from hydrological point of view. Among different type of models, the most frequently used are numerical models. They allow to assess the impact of green roofs on decrease and attenuation of runoff, reduction of peak runoff and value of water retention. This paper presents preliminary results of research on computing the rate of runoff from green ...

  10. On the Design of Suspended Roofs with Paraboloidal Surfaces

    Directory of Open Access Journals (Sweden)

    N. Ungureanu

    2006-01-01

    Full Text Available Some considerations concerning the design of the paraboloidal suspended roofs are made. The main geometric aspects are first time presented. For the roofs we propose, as pattern, the equivalent continuum membranes, and the efforts in the cable are determined by using the membrane efforts and their equations. Two examples are analyzed: elliptic paraboloide and hyperbolic paraboloide, with horizontal projection under the form of an ellipse.

  11. Composition and Diversity of Avian Communities Using a New Urban Habitat: Green Roofs

    Science.gov (United States)

    Washburn, Brian E.; Swearingin, Ryan M.; Pullins, Craig K.; Rice, Matthew E.

    2016-06-01

    Green roofs on buildings are becoming popular and represent a new component of the urban landscape. Public benefits of green roof projects include reduced stormwater runoff, improved air quality, reduced urban heat island effects, and aesthetic values. As part of a city-wide plan, several green roofs have been constructed at Chicago's O'Hare International Airport (ORD). Like some other landscaping features, green roofs on or near an airport might attract wildlife and thus increase the risk of bird-aircraft collisions. During 2007-2011, we conducted a series of studies to evaluate wildlife use of newly constructed green roofs and traditional (gravel) roofs on buildings at ORD. These green roofs were 0.04-1.62 ha in area and consisted of primarily stonecrop species for vegetation. A total of 188 birds were observed using roofs during this research. Of the birds using green roofs, 66, 23, and 4 % were Killdeer, European Starlings, and Mourning Doves, respectively. Killdeer nested on green roofs, whereas the other species perched, foraged, or loafed. Birds used green roofs almost exclusively between May and October. Overall, avian use of the green roofs was minimal and similar to that of buildings with traditional roofs. Although green roofs with other vegetation types might offer forage or cover to birds and thus attract potentially hazardous wildlife, the stonecrop-vegetated green roofs in this study did not increase the risk of bird-aircraft collisions.

  12. The gastrocoel roof plate in embryos of different frogs.

    Science.gov (United States)

    Sáenz-Ponce, Natalia; Santillana-Ortiz, Juan-Diego; del Pino, Eugenia M

    2012-02-01

    The morphology of the gastrocoel roof plate and the presence of cilia in this structure were examined in embryos of four species of frogs. Embryos of Ceratophrys stolzmanni (Ceratophryidae) and Engystomops randi (Leiuperidae) develop rapidly, provide comparison for the analysis of gastrocoel roof plate development in the slow-developing embryos of Epipedobates machalilla (Dendrobatidae) and Gastrotheca riobambae (Hemiphractidae). Embryos of the analyzed frogs develop from eggs of different sizes, and display different reproductive and developmental strategies. In particular, dorsal convergence and extension and archenteron elongation begin during gastrulation in embryos of rapidly developing frogs, as in Xenopus laevis. In contrast, cells that involute during gastrulation are stored in the large circumblastoporal collar that develops around the closed blastopore in embryos of slow-developing frogs. Dorsal convergence and extension only start after blastopore closure in slow-developing frog embryos. However, in the neurulae, a gastrocoel roof plate develops, despite the accumulation of superficial mesodermal cells in the circumblastoporal collar. Embryos of all four species develop a ciliated gastrocoel roof plate at the beginning of neurulation. Accordingly, fluid-flow across the gastrocoel roof plate is likely the mechanism of left-right asymmetry patterning in these frogs, as in X. laevis and other vertebrates. A ciliated gastrocoel roof plate, with a likely origin as superficial mesoderm, is conserved in frogs belonging to four different families and with different modes of gastrulation.

  13. A method for the design of longwall gateroad roof support

    Energy Technology Data Exchange (ETDEWEB)

    Lawrence, W. [Geowork Engineering, Emerald, Qld. (Australia)

    2009-06-15

    A longwall gateroad roof support design method for roadway development and panel extraction is demonstrated. It is a hybrid numerical and empirical method called gateroad roof support model (GRSM), where specification of roof support comes from charts or equations. GRSM defines suggested roof support densities by linking a rock-mass classification with an index of mining-induced stress, using a large empirical database of Bowen Basin mining experience. Inherent in the development of GRSM is a rock-mass classification scheme applicable to coal measure strata. Coal mine roof rating (CMRR) is an established and robust coal industry standard, while the geological strength index (GSI) may also be used to determine rock-mass geomechanical properties. An elastic three-dimensional numerical model was established to calculate an index of mining induced stress, for both roadway development and longwall retreat. Equations to calculate stress index derived from the numerical modelling have been developed. An industry standard method of quantifying roof support is adopted as a base template (GRSUP). The statistical analyses indicated that an improved quantification of installed support can be gained by simple modifications to the standard formulation of GRSUP. The position of the mathematically determined stable/failed boundary in the design charts can be changed depending on design criteria and specified risk.

  14. Modelling of green roofs' hydrologic performance using EPA's SWMM.

    Science.gov (United States)

    Burszta-Adamiak, E; Mrowiec, M

    2013-01-01

    Green roofs significantly affect the increase in water retention and thus the management of rain water in urban areas. In Poland, as in many other European countries, excess rainwater resulting from snowmelt and heavy rainfall contributes to the development of local flooding in urban areas. Opportunities to reduce surface runoff and reduce flood risks are among the reasons why green roofs are more likely to be used also in this country. However, there are relatively few data on their in situ performance. In this study the storm water performance was simulated for the green roofs experimental plots using the Storm Water Management Model (SWMM) with Low Impact Development (LID) Controls module (version 5.0.022). The model consists of many parameters for a particular layer of green roofs but simulation results were unsatisfactory considering the hydrologic response of the green roofs. For the majority of the tested rain events, the Nash coefficient had negative values. It indicates a weak fit between observed and measured flow-rates. Therefore complexity of the LID module does not affect the increase of its accuracy. Further research at a technical scale is needed to determine the role of the green roof slope, vegetation cover and drying process during the inter-event periods.

  15. Reliability Analysis of a Green Roof Under Different Storm Scenarios

    Science.gov (United States)

    William, R. K.; Stillwell, A. S.

    2015-12-01

    Urban environments continue to face the challenges of localized flooding and decreased water quality brought on by the increasing amount of impervious area in the built environment. Green infrastructure provides an alternative to conventional storm sewer design by using natural processes to filter and store stormwater at its source. However, there are currently few consistent standards available in North America to ensure that installed green infrastructure is performing as expected. This analysis offers a method for characterizing green roof failure using a visual aid commonly used in earthquake engineering: fragility curves. We adapted the concept of the fragility curve based on the efficiency in runoff reduction provided by a green roof compared to a conventional roof under different storm scenarios. We then used the 2D distributed surface water-groundwater coupled model MIKE SHE to model the impact that a real green roof might have on runoff in different storm events. We then employed a multiple regression analysis to generate an algebraic demand model that was input into the Matlab-based reliability analysis model FERUM, which was then used to calculate the probability of failure. The use of reliability analysis as a part of green infrastructure design code can provide insights into green roof weaknesses and areas for improvement. It also supports the design of code that is more resilient than current standards and is easily testable for failure. Finally, the understanding of reliability of a single green roof module under different scenarios can support holistic testing of system reliability.

  16. Green roofs and the LEED green building rating system

    Energy Technology Data Exchange (ETDEWEB)

    Kula, R. [Sustainable Solutions Inc., Wagoner, OK (United States)

    2005-07-01

    The sustainable building industry is becoming increasingly aware of the host of public and private benefits that green roofs can provide in built environments. In dense urban environments, green roofs function to reduce stormwater runoff, urban heat island effects, and particulate matter (PM) pollution. The emerging green roof industry is now poised to support the efforts of green building networks in North America. This paper discussed the general benefits of green roofs, and their recognition within the Leadership in Energy and Environmental Design (LEED) Green Building Rating System. A case study of Mountain Equipment Co-op's Winnipeg site was presented. The building's green roof was directly responsible for earning 5 credits and contributing to the achievement of an additional 2 credits under the LEEDS certification process. Credits were earned for reduced site disturbance; landscape design to reduce heat islands; and water efficiency. The green roof at the site provided the vast majority of the building's cooling needs through an evaporative cooling trough. A photovoltaic pump was used to feed the building's irrigation system, as well as to pump ground water through cooling valances. It was concluded that the rise of sustainable building practices and the LEED Green Building Rating System will revolutionize the way new buildings are constructed.

  17. Proposed Measures to Protect Temporary Roofs from Unwanted Heat Gains

    Directory of Open Access Journals (Sweden)

    Omar S. Asfour

    2017-06-01

    Full Text Available This study focuses on the uncompleted multi-storey residential buildings located in hot climates. This construction pattern is common in the case of incremental housing, where additional floors are added to the building as housing needs grow. Top roofs in these buildings are usually left without thermal insulation until the rest of upper floors are erected. This causes higher thermal discomfort in the top flats compared to the lower ones. Thus, the aim of this study is to investigate thermal effect of some proposed temporary measures that are intended to protect these roofs from unwanted heat gains until the rest of storeys are constructed. This has been carried out using thermal modelling to find out the effect of these measures on the amount of heat transfer through the roof in both summer and winter times. The analysis showed that it is possible to achieve competent thermal protection of the top roof compared to the layered thermal insulation using simple, cost-effective, and reversible measures. Among the examined measures, covering the roof with white foldable sheets and the use of pergolas have been found to be the most effective measures. In both cases, a reduction of 38% in conductive heat transfer through the top roof in summer was observed compared to the unprotected modelling case.

  18. Design and Analysis of Single Plate Blast Resistant Door

    Directory of Open Access Journals (Sweden)

    Nilesh S. Aitavade

    2013-06-01

    Full Text Available Blast Resistant Doors are used to withstand high intensity impulsive blast loads. They are designed to prevent the impact of the blast from travelling from one side to the other side of the door. Taking into account the limitations and the growing need of efficient blast resistant doors, a design was developed using ASTM A36 as the material of construction instead of concrete. Analytical calculations for the actual pressure-impulse loading condition were done as per the UFC 3-340-02, and the results of analytical calculations were compared with results of the simulation of the numerical model for the given boundary conditions.

  19. Exterior difference systems and invariance properties of discrete mechanics

    Energy Technology Data Exchange (ETDEWEB)

    Xie Zheng; Xie Duanqiang; Li Hongbo [Center of Mathematical Sciences, Zhejiang University, Zhejiang 310027 (China); Key Laboratory of Mathematics Mechanization, Chinese Academy of Sciences, Beijing 100080 (China)], E-mail: lenozhengxie@yahoo.com.cn

    2008-06-27

    Invariance properties describe the fundamental physical laws in discrete mechanics. Can those properties be described in a geometric way? We investigate an exterior difference system called the discrete Euler-Lagrange system, whose solution has one-to-one correspondence with solutions of discrete Euler-Lagrange equations, and use it to define the first integrals. The preservation of the discrete symplectic form along the discrete Hamilton phase flows and the discrete Noether's theorem is also described in the language of difference forms.

  20. Discrete Exterior Calculus Discretization of Incompressible Navier-Stokes Equations

    KAUST Repository

    Mohamed, Mamdouh S.

    2017-05-23

    A conservative discretization of incompressible Navier-Stokes equations over surface simplicial meshes is developed using discrete exterior calculus (DEC). Numerical experiments for flows over surfaces reveal a second order accuracy for the developed scheme when using structured-triangular meshes, and first order accuracy otherwise. The mimetic character of many of the DEC operators provides exact conservation of both mass and vorticity, in addition to superior kinetic energy conservation. The employment of barycentric Hodge star allows the discretization to admit arbitrary simplicial meshes. The discretization scheme is presented along with various numerical test cases demonstrating its main characteristics.

  1. Implantación de ascensores exteriores en edificios existentes

    OpenAIRE

    Abad Herrero, Mónica

    2015-01-01

    En la ciudad de Barcelona desde 2001 se han construido ascensores por el exterior de edificios ya existentes, edificios los cuales no disponían. El objetivo es estudiar cómo se inicia el fenómeno, las problemáticas surgidas y soluciones adoptadas y enmarcar a nivel socio-cultural y urbanístico el origen de los barrios donde se ubican los edificios de viviendas afectados. El método empleado, limites de estudio (ciudad de Barcelona), la organización de la investigación (almacenamien...

  2. Regression on manifolds: Estimation of the exterior derivative

    CERN Document Server

    Aswani, Anil; Tomlin, Claire; 10.1214/10-AOS823

    2011-01-01

    Collinearity and near-collinearity of predictors cause difficulties when doing regression. In these cases, variable selection becomes untenable because of mathematical issues concerning the existence and numerical stability of the regression coefficients, and interpretation of the coefficients is ambiguous because gradients are not defined. Using a differential geometric interpretation, in which the regression coefficients are interpreted as estimates of the exterior derivative of a function, we develop a new method to do regression in the presence of collinearities. Our regularization scheme can improve estimation error, and it can be easily modified to include lasso-type regularization. These estimators also have simple extensions to the "large $p$, small $n$" context.

  3. Perturbation of essential spectra of exterior elliptic problems

    DEFF Research Database (Denmark)

    Grubb, Gerd

    2011-01-01

    For a second-order symmetric strongly elliptic differential operator on an exterior domain in ℝ n , it is known from the works of Birman and Solomiak that a change in the boundary condition from the Dirichlet condition to an elliptic Neumann or Robin condition leaves the essential spectrum...... an extension of the spectral asymptotics formula for the difference between inverses of elliptic problems. The proofs rely on Kreĭn-type formulae for differences between inverses, and cutoff techniques, combined with results on singular Green operators and their spectral asymptotics....

  4. Fracturing characteristics of main roof strata when mining uphill and downhill and its effect on stability of immediate roof

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Q.; Liu, J.; Zhang, Y. (Shanxi Mining Institute (China))

    1994-04-01

    The main roof strata in uphill and downhill mining of an inclined longwall may be regarded as an elastic plate. When the ratio of longwall and short span is greater than 2, the load is mainly carried by the short span. Based on this, the authors take a unit width of an inclined rock beam in the direction of face advance and a mechanical model for studying initial and periodic weighting of the main roof was established. It shows that the interval of periodic weighting and abutment pressure in uphill mining are less than that of downhill mining and the distribution of abutment pressure in both cases is quite different. Manifestation of ground pressure in uphill mining is more evident than downhill mining. It is proved that when uphill mining is introduced, the immediate roof is less stable and roof failures are frequent due to stress component in the direction of rock strata and to spalling of coal rib. When the direction of stress component is the same as face advance, the immediate roof is more stable and vice versa if the contrary. From the roof control point of view, where conditions are favourable, priority should be given to downhill mining. 4 refs., 11 figs., 1 tab.

  5. Comment on the Exterior Solutions and Their Geometry in Scalar-Tensor Theories of Gravity

    Science.gov (United States)

    Tsuchida, T.; Watanabe, K.

    1999-01-01

    We study series of stationary solutions with asymptotic flatness properties in the Einstein-Maxwell-free scalar system because they are locally equivalent to the exterior solutions in some class of scalar-tensor theories of gravity. First, we classify spherical exterior solutions into two types of solutions, an apparently black hole type solution and an apparently worm hole type solution. The solutions contain three parameters, and we clarify their physical significance. Second, we reduce the field equations for the axisymmetric exterior solutions. We find that the reduced equations are partially the same as the Ernst equations. As simple examples, we derive new series of static, axisymmetric exterior solutions, which correspond to Voorhees's solutions. We then establish a non-trivial relation between the spherical exterior solutions and our new solutions. Finally, since null geodesics have conformally invariant properties, we study the local geometry of the exterior solutions by using the optical scalar equations and find some anomalous behavior of the null geodesics.

  6. Comment on the exterior solutions and their geometry in scalar-tensor theories of gravity

    CERN Document Server

    Tsuchida, T; Tsuchida, Tooru; Watanabe, Kazuya

    1999-01-01

    We study series of the stationary solutions with asymptotic flatness properties in the Einstein-Maxwell-free scalar system because they are locally equivalent with the exterior solutions in some class of the scalar-tensor theories of gravity. First, we classify spherical exterior solutions into two types of the solutions, an apparently black hole type solution and an apparently worm hole type solution. The solutions contain three parameters, and we clarify their physical significance. Second, we reduce the field equations for the axisymmetric exterior solutions. We find that the reduced equations are partially the same as the Ernst equations. As simple examples, we derive new series of the static, axisymmetric exterior solutions, which correspond to Voorhees's solutions. We then show a non-trivial relation between the spherical exterior solutions and our new solutions. Finally, since null geodesics have conformally invariant properties, we study the local geometry of the exterior solutions by using the optica...

  7. Seismic Experimental Study on New-Type Composite Exterior Wallboard with Integrated Structural Function and Insulation

    Directory of Open Access Journals (Sweden)

    Shaochun Ma

    2015-06-01

    Full Text Available In order to evaluate the seismic performance of new-type composite exterior wallboard, a total of six exterior and interior wallboards were incorporated in the experiment of seismic performance. Seismic performance such as the stress process, damage mode, hysteresis and skeleton curve, load-carrying and ductility coefficient, damping and energy dissipation, stiffness degradation as well as material strain of the exterior wallboards were analyzed with emphasis and compared with interior wallboards. Results of the experiment and analysis showed that both interior and exterior wallboards exhibited outstanding seismic performance. Due to the existence of insulation layer and externally bonded single gypsum board, the capacity of elastoplastic deformation and seismic energy dissipation of the exterior wallboards was improved and each seismic performance indicator of the exterior wallboards outperformed the interior wallboards.

  8. Temperature reduction in attic and ceiling via insulation of several passive roof designs

    Energy Technology Data Exchange (ETDEWEB)

    Ong, K.S., E-mail: Ong.Kok.Seng@eng.monash.edu.m [Monash University Sunway Campus, Jalan Lagoon Selatan, 46150 Bandar Sunway (Malaysia)

    2011-06-15

    Research highlights: {yields} Six passive roof designs were tested simultaneously outdoors. {yields} Roof, attic and ceiling temperatures were determined. {yields} Solar collector roof design provided the coolest attic and ceiling. {yields} Placing insulation under roof is preferred to above ceiling. -- Abstract: High ambient temperatures coupled with high humidity lead to uncomfortable conditions that are non-conducive for human comfort and productivity. Heat transmission through the roof could be reduced by providing insulation in the attic under the roof or above the ceiling. A roof solar collector could provide both ventilation and cooling in the attic. Several laboratory sized units of passive roof designs were constructed and tested side-by-side under outdoor conditions to obtain temperature data of the roof, attic and ceiling in order to compare their performances.

  9. Inclusion of cool roofs in nonresidential Title 24 prescriptive requirements

    Energy Technology Data Exchange (ETDEWEB)

    Levinson, Ronnen; Akbari, Hashem; Konopacki, Steve; Bretz, Sarah

    2002-12-15

    Roofs that have high solar reflectance (high ability to reflect sunlight) and high thermal emittance (high ability to radiate heat) tend to stay cool in the sun. The same is true of low-emittance roofs with exceptionally high solar reflectance. Substituting a cool roof for a noncool roof tends to decrease cooling electricity use, cooling power demand, and cooling-equipment capacity requirements, while slightly increasing heating energy consumption. Cool roofs can also lower the ambient air temperature in summer, slowing ozone formation and increasing human comfort. DOE-2.1E building energy simulations indicate that use of a cool roofing material on a prototypical California nonresidential building with a low-sloped roof yields average annual cooling energy savings of approximately 300 kWh/1000 ft2 [3.2 kWh/m2], average annual natural gas deficits of 4.9 therm/1000 ft2 [5.6 MJ/m2], average source energy savings of 2.6 MBTU/1000 ft2 [30 MJ/m2], and average peak power demand savings of 0. 19 kW/1000 ft2 [2.1 W/m2]. The 15-year net present value (NPV) of energy savings averages $450/1000 ft2 [$4.90/m2] with time dependent valuation (TDV), and $370/1000 ft2 [$4.00/m2] without TDV. When cost savings from downsizing cooling equipment are included, the average total savings (15-year NPV + equipment savings) rises to $550/1000 ft2 [$5.90/m2] with TDV, and to $470/1000 ft2 [$5.00/m2] without TDV. Total savings range from 0.18 to 0.77 $/ft2 [1.90 to 8.30 $/m2] with TDV, and from 0.16 to 0.66 $/ft2 [1.70 to 7.10 $/m2] without TDV, across California's 16 climate zones. The typical cost premium for a cool roof is 0.00 to 0.20 $/ft2 [0.00 to 2.20 $/m2]. Cool roofs with premiums up to $0.20/ft2 [$2.20/m2] are expected to be cost effective in climate zones 2 through 16; those with premiums not exceeding $0.18/ft2 [$1.90/m2] are expected to be also cost effective in climate zone 1. Hence, this study recommends that the year-2005 California building energy efficiency code (Title

  10. La Constitución de 1991 y la política exterior colombiana

    Directory of Open Access Journals (Sweden)

    Bernardo Vela Orbegozo

    2008-01-01

    Full Text Available Introducción. i. Una política exterior para un mundo en transformación. ii. El viejo orden y la transformación de las relaciones internacionales. iii. La precariedad de la política exterior colombiana. iv. A manera de conclusión: la política exterior de un Estado legítimo

  11. La Constitución de 1991 y la política exterior colombiana

    Directory of Open Access Journals (Sweden)

    Bernardo Vela Orbegozo

    2008-12-01

    Full Text Available introducción. i. Una política exterior para un mundo en transformación. ii. El viejo orden y la transformación de las relaciones internacionales. iii. La precariedad de la política exterior colombiana. iv. A manera de conclusión: la política exterior de un Estado legítimo

  12. Opto-mechanical door locking system

    Science.gov (United States)

    Patil, Saurabh S.; Rodrigues, Vanessa M.; Patil, Ajeetkumar; Chidangil, Santhosh

    2015-09-01

    We present an Opto-mechanical Door Locking System which is an optical system that combines a simple combination of a coherent light source (Laser) and a photodiode based sensor with focus toward security applications. The basic construct of the KEY comprises a Laser source in a cylindrical enclosure that slides perfectly into the LOCK. The Laser is pulsed at a fixed encrypted frequency unique to that locking system. Transistor-transistor logic (TTL) circuitry is used to achieve encryption. The casing of the key is designed in such a way that it will power the pulsing laser only when the key is inserted in the slot provided for it. The Lock includes a photo-sensor that will convert the detected light intensity to a corresponding electrical signal by decrypting the frequency. The lock also consists of a circuit with a feedback system that will carry the digital information regarding the encryption frequency code. The information received from the sensor is matched with the stored code; if found a perfect match, a signal will be sent to the servo to unlock the mechanical lock or to carry out any other operation. This technique can be incorporated in security systems for residences and safe houses, and can easily replace all conventional locks which formerly used fixed patterns to unlock. The major advantage of this proposed optomechanical system over conventional ones is that it no longer relies on a solid/imprinted pattern to perform its task and hence makes it almost impossible to tamper with.

  13. Manipulating soil microbial communities in extensive green roof substrates.

    Science.gov (United States)

    Molineux, Chloe J; Connop, Stuart P; Gange, Alan C

    2014-09-15

    There has been very little investigation into the soil microbial community on green roofs, yet this below ground habitat is vital for ecosystem functioning. Green roofs are often harsh environments that would greatly benefit from having a healthy microbial system, allowing efficient nutrient cycling and a degree of drought tolerance in dry summer months. To test if green roof microbial communities could be manipulated, we added mycorrhizal fungi and a microbial mixture ('compost tea') to green roof rootzones, composed mainly of crushed brick or crushed concrete. The study revealed that growing media type and depth play a vital role in the microbial ecology of green roofs. There are complex relationships between depth and type of substrate and the biomass of different microbial groups, with no clear pattern being observed. Following the addition of inoculants, bacterial groups tended to increase in biomass in shallower substrates, whereas fungal biomass change was dependent on depth and type of substrate. Increased fungal biomass was found in shallow plots containing more crushed concrete and deeper plots containing more crushed brick where compost tea (a live mixture of beneficial bacteria) was added, perhaps due to the presence of helper bacteria for arbuscular mycorrhizal fungi (AMF). Often there was not an additive affect of the microbial inoculations but instead an antagonistic interaction between the added AM fungi and the compost tea. This suggests that some species of microbes may not be compatible with others, as competition for limited resources occurs within the various substrates. The overall results suggest that microbial inoculations of green roof habitats are sustainable. They need only be done once for increased biomass to be found in subsequent years, indicating that this is a novel and viable method of enhancing roof community composition.

  14. Developing resilient green roofs in a dry climate.

    Science.gov (United States)

    Razzaghmanesh, M; Beecham, S; Brien, C J

    2014-08-15

    Living roofs are an emerging green infrastructure technology that can potentially be used to ameliorate both climate change and urban heat island effects. There is not much information regarding the design of green roofs for dry climates and so the aim of this study was to develop low maintenance and unfertilized green roofs for a dry climate. This paper describes the effects of four important elements of green roofs namely slope, depth, growing media and plant species and their possible interactions in terms of plant growth responses in a dry climate. Sixteen medium-scale green roofs were set up and monitored during a one year period. This experiment consisted of twelve vegetated platforms and four non-vegetated platforms as controls. The design for the experiment was a split-split-plot design in which the factors Slope (1° and 25°) and Depth (100mm, 300 mm) were randomized to the platforms (main plots). Root depth and volume, average height of plants, final dry biomass and ground cover, relative growth rate, final dry shoot-root ratio, water use efficiency and leaf succulence were studied during a twelve month period. The results showed little growth of the plants in media type A, whilst the growth was significant in both media types B and C. On average, a 90% survival rate of plants was observed. Also the growth indices indicated that some plants can grow efficiently in the harsh environment created by green roofs in a dry climate. The root growth pattern showed that retained water in the drainage layer is an alternative source of water for plants. It was also shown that stormwater can be used as a source of irrigation water for green roofs during six months of the year at the study site. In summary, mild sloping intensive systems containing media type C and planted with either Chrysocephalum apiculatum or Disphyma crassifolium showed the best performance.

  15. Comparison of Software Models for Energy Savings from Cool Roofs

    Energy Technology Data Exchange (ETDEWEB)

    New, Joshua Ryan [ORNL; Miller, William A [ORNL; Huang, Yu (Joe) [White Box Technologies; Levinson, Ronnen [Lawrence Berkeley National Laboratory (LBNL)

    2014-01-01

    A web-based Roof Savings Calculator (RSC) has been deployed for the United States Department of Energy as an industry-consensus tool to help building owners, manufacturers, distributors, contractors and researchers easily run complex roof and attic simulations. This tool employs modern web technologies, usability design, and national average defaults as an interface to annual simulations of hour-by-hour, whole-building performance using the world-class simulation tools DOE-2.1E and AtticSim in order to provide estimated annual energy and cost savings. In addition to cool reflective roofs, RSC simulates multiple roof and attic configurations including different roof slopes, above sheathing ventilation, radiant barriers, low-emittance roof surfaces, duct location, duct leakage rates, multiple substrate types, and insulation levels. A base case and energy-efficient alternative can be compared side-by-side to estimate monthly energy. RSC was benchmarked against field data from demonstration homes in Ft. Irwin, California; while cooling savings were similar, heating penalty varied significantly across different simulation engines. RSC results reduce cool roofing cost-effectiveness thus mitigating expected economic incentives for this countermeasure to the urban heat island effect. This paper consolidates comparison of RSC s projected energy savings to other simulation engines including DOE-2.1E, AtticSim, Micropas, and EnergyPlus, and presents preliminary analyses. RSC s algorithms for capturing radiant heat transfer and duct interaction in the attic assembly are considered major contributing factors to increased cooling savings and heating penalties. Comparison to previous simulation-based studies, analysis on the force multiplier of RSC cooling savings and heating penalties, the role of radiative heat exchange in an attic assembly, and changes made for increased accuracy of the duct model are included.

  16. Evaluation of solar energy on the roofs of livestock houses

    Directory of Open Access Journals (Sweden)

    Paolo Liberati

    2013-03-01

    Full Text Available There is a great potential for production of thermal and electrical energy by means of solar collectors on farms. To assess in advance the performance of the alternative plant solutions, a computational model for the determination of solar energy absorbed by surfaces with different exposures as a function of latitude, day, orientation and inclination has been created. Its application to roofs of buildings typically used for animal housing is presented; these were mono-pitch, gabled, and shed type roofs. For each building, the annual energy absorption per unit of floor area is calculated by varying orientation and slope of the pitches. For roof surfaces exposed only in one direction (mono-pitch or shed, the orientation is shown to be a dominant factor with respect to the slope in determining the annual energy uptake. The maximum uptake is obtained with exposure to the south and is greater the higher the slope (up to 67.5%. For gabled roofs, the total uptake is negatively affected by the worse exposed pitch and does not vary significantly, for a given slope, with orientation (up to 2.8%. The maximum gain is obtained with the optimal building azimuth (0° and the highest slope. The shed type, since it is affected by the shade induced by the upper pitch over the lower, cannot reach the level of a mono-pitch roof: -1.5% with a slope of 10% and -21% with a slope of 67.5% with the optimal building azimuth of 90°. However, its performance is slightly higher than the corresponding gabled roof (+2.5%, therefore, it could be a convenient alternative if optimally oriented and, above all, if the collectors are installed on the predominantly sunny part of the roof.

  17. SOFIA Closed- and Open-Door Aerodynamic Analyses

    Science.gov (United States)

    Cumming, Stephen; Frederick, Mike; Smith, Mark

    2012-01-01

    Work to evaluate the aerodynamic characteristics and the cavity acoustic environment of the SOFIA (Stratospheric Observatory for Infrared Astronomy) airplane has been completed. The airplane has been evaluated in its closed-door configuration, as well as several open-door configurations. Work performed included: acoustic analysis tool development, cavity acoustic evaluation, stability and control parameter estimation, air data calibration, and external flow evaluation. Qualitative airflow data were obtained during the closed- and open-door flights using tufts on the aft portion of the fuselage. Video was taken from a chase plane. This video was analyzed for various flight conditions, and general flow descriptions of the aft fuselage of the 747SP were developed for the different closed and open door configurations.

  18. Ontwateren van zeugenmest door middel van omgekeerde osmose

    NARCIS (Netherlands)

    Thelosen, J.; Gastel, van J.; Cuyck, van J.

    1992-01-01

    In periodiek nummer 1 (februari 1991) is het proces van omgekeerde osmose reeds beschreven. In het kort komt omgekeerde osmose op het volgende neer: de te ontwateren vloeistof wordt onder hoge druk (55 bar) door filterbuizen gepompt.

  19. Rotational and frictional dynamics of the slamming of a door

    Science.gov (United States)

    Klein, Pascal; Müller, Andreas; Gröber, Sebastian; Molz, Alexander; Kuhn, Jochen

    2017-01-01

    A theoretical and experimental investigation of the rotational dynamics, including friction, of a slamming door is presented. Based on existing work regarding different damping models for rotational and oscillatory motions, we examine different forms for the (angular) velocity dependence (ωn, n = 0, 1, 2) of the frictional force. An analytic solution is given when all three friction terms are present and several solutions for specific cases known from the literature are reproduced. The motion of a door is investigated experimentally using a smartphone, and the data are compared with the theoretical results. A laboratory experiment under more controlled conditions is conducted to gain a deeper understanding of the movement of a slammed door. Our findings provide quantitative evidence that damping models involving quadratic air drag are most appropriate for the slamming of a door. Examining this everyday example of a physical phenomenon increases student motivation, because they can relate it to their own personal experience.

  20. Energiebesparing bij de bewaring van plantgoed van tulp door temperatuurintegratie

    NARCIS (Netherlands)

    Gude, H.; Dijkema, M.H.G.E.

    2006-01-01

    Onderzoek naar de mogelijkheden van TI (temperatuurintegratie) bij de bewaring van tulpenplantgoed door het vaststellen van de tolerantie van enkele cultivars voor verhogingen van de dagtemperatuur en verlagingen van de nachttemperatuur

  1. Epidemiologie en basisgezondheidszorg : analyse van volksgezondheid door basisgezondheidsdiensten

    NARCIS (Netherlands)

    Davidse, W.; Ginneken, J.K.S. van; Water, H.P.A. van de

    1989-01-01

    Dit boekje bevat de bijdragen aan het symposium, dat op 30 september 1988 werd georganiseerd door de sector Gezondheidszorg en Epidemiologie van het Nederlands Instituut voor Praeventieve Gezondheidszorg/TNO te Leiden.

  2. An Integrative Analysis of an Extensive Green Roof System: A Case Study of the Schleman Green Roof

    Science.gov (United States)

    Hoover, F.; Bowling, L. C.

    2013-12-01

    In urban environments where populations continue to rise, the need for affective stormwater management and runoff control methods is ever prevalent. Increased population growth and city expansion means greater impervious surfaces and higher rates of stormwater runoff. In well-established cities, this proves particularly difficult due to a constraining built environment and limited pervious spaces, even in cities as small as 40,000 residents. Work to reduce runoff in combined sewer systems (CSS) and municipal separated storm sewer systems (MS4) by use of best-management practices is one route currently under investigation. The Purdue University campus is making efforts to reduce their impact on the West Lafayette CSS and MS4. Green roofs are one management practice being used for runoff mitigation. Specifically, Schleman Hall, an administrative student affairs building, has a small green roof located on the second floor installed in 2008. In cooperation with Purdue Physical Facilities, monitoring and analysis for the Schleman extensive green roof at Purdue University was performed from June 2012 to December 2012. The objective was to determine the stormwater retention, output water quality and net present value for the 165 m2 roof. The results from the water balance analysis revealed retention rates on average of 58% of precipitation per rain event, where retention included soil moisture, evaporation and detention/depression storage. The water quality metrics tested were Nitrate-Nitrite (NO2-NO3), Orthophosphate (PO4), Ammonia-Ammonium ion (NH3-NH4), Sulfate (SO4), total suspended solids (TSS) and pH. The pollutant concentration and load results varied, but the pH levels from precipitation increased in all samples after passing through the substrate. SO4 and PO4 results yielded higher concentrations and loads in the green roof output than the control output and precipitation, while NO2-NO3 and NH3-NH4 yielded concentrations and loads that were reduced by the green

  3. Measurement of spatial object's exterior attitude based on linear CCD

    Institute of Scientific and Technical Information of China (English)

    2008-01-01

    It is difficult to realize real-time measurement of exterior attitude by the traditional systems based on the area image sensor which have conflict between speed and accuracy.The subsystem for three-dimensional (3D) coordinate rcconstruction of point target (S3DCRPT) which is composed of three one-dimensional (1D) cameras based on linear charge-coupled device (CCD) can determine the distant light spots' spatial position. The attitude angle of the measured object is determined by the spatial solution while the coordinate reconstruction is separately carried on by the S3DCRPT with some point cooperation targets (PCTs) on the measured object. A new optical system is designed to solve the interference problem with one-to-one relationship between the PCTs and the S3DCRPT optical subsystems,which improves the measurement accuracy and saves space. The mathematical model of the attitude measurement is established,and partial and global calibrations are realized for the multi-camera attitude measurement system.The test results show the feasibility of the exterior attitude measurement based on linear CCD.

  4. CARACTERÍSTICAS DO JOVEM BRASILEIRO QUE VIAJA AO EXTERIOR

    Directory of Open Access Journals (Sweden)

    Sabrina Nascimento Moraes

    2016-11-01

    Full Text Available O Estudo para compreender as características dos jovens que viaja ao exterior, foi realizada por meio de um questionário ao qual a amostra de jovens pode responder. O questionário sintético buscou entender quem era nossa amostra, como faixa etária, renda familiar e avaliar alguns dados como o envolvimento do mesmo com projetos sociais e visão de mundo, os questionamentos abrangentes e específicos nos possibilitou atingir nossa finalidade que é assimilar diversos aspectos que possam ter motivado o jovem brasileiro a viajar para o exterior. O enfoque do proposto estudo é captar e interpretar as mudanças que este jovem pós-viagem, possa ter passado após o contato com outra (s cultura, costumes e experiências que podem ter e reflexos e influenciar de maneira significante, por esse novo ambiente de contato. O trabalho busca também compreender o como a crise econômica brasileira (e mundial tem na decisão de viajar, possibilitando um novo rumo longe de famílias e amigos, em busca de novas experiências.

  5. The Search for Durable Exterior Clear Coatings for Wood

    Directory of Open Access Journals (Sweden)

    Philip D. Evans

    2015-11-01

    Full Text Available The goal of a durable exterior clear coating has eluded generations of coatings technologists, despite long-standing desire amongst the public for such a coating. The journey towards this goal initially focused on modifications to coating formulation, but took a completely different direction when it was found that a UV-transparent silicone clear coating on wood modified with chromic acid met consumer expectations of coating durability. This finding sparked world-wide interest in wood pre-treatments as a way of enhancing the durability of clear coatings. This interest initially focused on transition metal compounds, but has now shifted in the direction of organic and inorganic photostabilizers or even more drastic pre-treatments. Pre-treatments that dimensionally stabilize wood, protect it from microbial degradation and photostabilize lignin, when combined with flexible, photostable, coatings provide the next way-stop on the journey towards achieving the goal of durable exterior clear coatings for wood. This paper reviews this journey, drawing upon our research and that of other groups who have focused on this elusive goal.

  6. Occurrence, Distribution, and Accumulation of Pesticides in Exterior Residential Areas.

    Science.gov (United States)

    Jiang, Weiying; Conkle, Jeremy L; Luo, Yuzhou; Li, Juying; Xu, Karen; Gan, Jay

    2016-12-06

    Pesticides are commonly applied around residential homes, but their occurrence on exterior surfaces (e.g., pavement) has not been thoroughly evaluated. We collected 360 dust samples from curbside gutters, sidewalks, and street surfaces at 40 houses in southern California to evaluate pesticide occurrence on urban paved surfaces as well as their spatial and temporal distributions. Pesticides and select degradates were ubiquitously detected in dust, with the median concentration of total target analytes at 85 μg kg(-1). A total of 75% of samples contained at least five pesticides. As a result of recurring pesticide applications, concentrations increased throughout the summer. The pyrethroids bifenthrin and permethrin accounted for 55% of total pesticides detected in the dust. The highest concentrations in dust were found on the sidewalk and in the gutter. Relative to indoor environments, human exposure risk to pesticides on paved surfaces was estimated to be lower, with the highest potential oral and dermal exposure predicted to be 38 ng day(-1) for permethrin. The ubiquitous detection of pesticides on residential outdoor surfaces and the fact that the exterior concentrations did not correlate to the indoor areas highlight the necessity to measure pesticides in both indoor and outdoor areas for complete residential pesticide risk assessment.

  7. Landing Gear Door Liners for Airframe Noise Reduction

    Science.gov (United States)

    Jones, Michael G. (Inventor); Howerton, Brian M. (Inventor); Van De Ven, Thomas (Inventor)

    2014-01-01

    A landing gear door for retractable landing gear of aircraft includes an acoustic liner. The acoustic liner includes one or more internal cavities or chambers having one or more openings that inhibit the generation of sound at the surface and/or absorb sound generated during operation of the aircraft. The landing gear door may include a plurality of internal chambers having different geometries to thereby absorb broadband noise.

  8. Cool roofs and the influence on the energy consumption under Danish conditions

    DEFF Research Database (Denmark)

    Brandt, Erik; Bunch-Nielsen, Tommy; Juhl, Lasse

    that there are no significant advantages of using white roofing felt instead of dark under Danish conditions in common buildings with active heating and passive cooling. Quite to the contrary it appears that dark roofing felts have significant advantages over white roofing felts. The results are discussed in the paper....... It should be mentioned that white roofing materials might be beneficial for poorly insulated buildings with high internal heat loads. In this case the white roofing might contribute to a reduced cooling. Also buildings with constant cooling demands or cold-storage plants etc. may benefit from white roofing...

  9. A comparative analysis of selected parameters of roofing used in the Polish construction industry

    Directory of Open Access Journals (Sweden)

    Radziszewska-Zielina Elżbieta

    2014-06-01

    Full Text Available Roofing is an important element in the construction of the roof. It is also one of the essential elements of the whole building. The choice of roofing should depend on technical parameters that affect the quality of the materials used and the price. The present paper is a comparative analysis of the properties of five roofing materials selected as examples with respect to twelve parameters. As can be seen from the comparative analysis of the roofing parameters, roofing tile is by far the best material, receiving the highest score in the ranking

  10. Door Opening Affects Operating Room Pressure During Joint Arthroplasty.

    Science.gov (United States)

    Mears, Simon C; Blanding, Renee; Belkoff, Stephen M

    2015-11-01

    Many resources are expended to ensure a sterile operating room environment. Efforts are made to prevent exposure of patients to personnel and to achieve positive room pressure to keep out airborne contaminants. Foot traffic into and out of the operating room during surgery can undermine these efforts. The authors investigated the number and duration of operating room door openings during hip and knee arthroplasty procedures and the effect of the door openings on room pressure. They tested the hypothesis that door openings defeat positive pressure, permitting air flow into the room. Room pressure and door status were monitored electronically during 191 hip and knee arthroplasty procedures. Operating room staff were unaware that data were being collected. The authors evaluated the data with regression analysis to determine whether the number and duration of door openings had an effect on room pressure. Significance was set at Poperating room. Total time with the door open significantly affected the minimum pressure recorded in the room (Poperating room sterility. The causes of excessive operating room traffic must be evaluated to identify ways to reduce this traffic and the associated risks.

  11. Air curtain development: an energy harvesting solution for hinged doors

    Science.gov (United States)

    Dayal, Vineed; Lee, Soobum

    2017-04-01

    The paper proposes a fully mechanical air curtain system that will be powered solely by harvested energy from common hinged doors. The average person uses this type of door several times a day with an almost unconscious amount of applied force and effort. This leads to a high potential of energy to be harvested in doorways that see high traffic and frequent operation7 . Frequently opened door entry ways have always been regarded as a major element that causes significant energy loss and contaminated air conditions in buildings6 . Private companies, particularly those with warehouses, have introduced commercial electrical air curtains to block the open entrances from invading cold air11. This project intends to introduce an original design of air curtain which operates fans only when the door opens and closes, by directly converting door motion to fan rotation without any electronic motor or power cable. The air stream created by this device will prevent the transfer of outside air and contaminants. Research will be conducted to determine the most efficient method of harvesting energy from door use, and the prototyping process will be conducted to meet the required performance of current air curtain models.

  12. Blower-door techniques for measuring interzonal leakage

    Energy Technology Data Exchange (ETDEWEB)

    Hult, Erin L.; Sherman, Max H.; Walker, Iain

    2013-01-01

    Abstract The standard blower door test methods, such as ASTM E779, describe how to use a single blower door to determine the total leakage of a single-zone structure such as a detached single-family home. There are no standard test methods for measuring interzonal leakage in a two-zone or multi-zone building envelope such as might be encountered in with an attached garage or in a multifamily building. Some practitioners have been using techniques that involve making multiple measurements with a single blower door as well as combined measurements using multiple blower doors. Even for just two zones there are dozens of combinations of one-door and two-door test protocols that could conceivably be used to determine the interzonal air tightness. We examined many of these two-zone configurations using both simulation and measured data to estimate the accuracy and precision of each technique for realistic measurement scenarios. We also considered the impact of taking measurements at a single pressure versus over multiple pressures. We compared the various techniques and evaluated them for specific uses. Some techniques work better in one leakage regime; some are more sensitive to wind and other noise; some are more suited to determining only a subset of the leakage values. This paper makes recommendations on which techniques to use or not use for various cases and provides data that could be used to develop future test methods.

  13. Roof heat loss detection using airborne thermal infrared imagery

    Science.gov (United States)

    Kern, K.; Bauer, C.; Sulzer, W.

    2012-12-01

    As part of the Austrian and European attempt to reduce energy consumption and greenhouse gas emissions, thermal rehabilitation and the improvement of the energy efficiency of buildings became an important topic in research as well as in building construction and refurbishment. Today, in-situ thermal infrared measurements are routinely used to determine energy loss through the building envelope. However, in-situ thermal surveys are expensive and time consuming, and in many cases the detection of the amount and location of waste heat leaving building through roofs is not possible with ground-based observations. For some years now, a new generation of high-resolution thermal infrared sensors makes it possible to survey heat-loss through roofs at a high level of detail and accuracy. However, to date, comparable studies have mainly been conducted on buildings with uniform roof covering and provided two-dimensional, qualitative information. This pilot study aims to survey the heat-loss through roofs of the buildings of the University of Graz (Austria) campus by using high-resolution airborne thermal infrared imagery (TABI 1800 - Thermal Airborne Broadband imager). TABI-1800 acquires data in a spectral range from 3.7 - 4.8 micron, a thermal resolution of 0.05 °C and a spatial resolution of 0.6 m. The remote sensing data is calibrated to different roof coverings (e.g. clay shingle, asphalt shingle, tin roof, glass) and combined with a roof surface model to determine the amount of waste heat leaving the building and to identify hot spots. The additional integration of information about the conditions underneath the roofs into the study allows a more detailed analysis of the upward heat flux and is a significant improvement of existing methods. The resulting data set provides useful information to the university facility service for infrastructure maintenance, especially in terms of attic and roof insulation improvements. Beyond that, the project is supposed to raise public

  14. Empirically Derived Strength of Residential Roof Structures for Solar Installations.

    Energy Technology Data Exchange (ETDEWEB)

    Dwyer, Stephen F.; Sanchez, Alfred; Campos, Ivan A.; Gerstle, Walter H.

    2014-12-01

    Engineering certification for the installation of solar photovoltaic (PV) modules on wood roofs is often denied because existing wood roofs do not meet structural design codes. This work is intended to show that many roofs are actually sufficiently strong given the conservatism in codes, documented allowable strengths, roof structure system effects, and beam composite action produced by joist-sheathing interaction. This report provides results from a testing program to provide actual load carrying capacity of residential rooftops. The results reveal that the actual load carrying capacity of structural members and systems tested are significantly stronger than allowable loads provided by the International Residential Code (IRC 2009) and the national structural code found in Minimum Design Loads for Buildings and Other Structures (ASCE 7-10). Engineering analysis of residential rooftops typically ignores the system affects and beam composite action in determining rooftop stresses given a potential PV installation. This extreme conservatism combined with conservatism in codes and published allowable stress values for roof building materials (NDS 2012) lead to the perception that well built homes may not have adequate load bearing capacity to enable a rooftop PV installation. However, based on the test results presented in this report of residential rooftop structural systems, the actual load bearing capacity is several times higher than published values (NDS 2012).

  15. Effect of Composite Action on the Strength of Wood Roofs

    Directory of Open Access Journals (Sweden)

    Ivan A. Campos Varela

    2015-01-01

    Full Text Available Engineering certification for the installation of solar photovoltaic modules on wood roofs is often denied because existing wood roofs do not meet current building codes. Rather than requiring expensive structural retrofits, we desire to show that many roofs are actually sufficiently strong if the effect of composite action produced by joist-sheathing interaction is considered. In a series of laboratory experiments using a limited number of two-by-four wood joists with and without sheathing panels, conventionally sheathed stud-grade joists, surprisingly, exhibited between 18% and 63% higher nominal strength than similar bare joists. To explain this strength increase, a simple model was developed to predict the strengths of the nailed partially composite sections, but the model only justifies a 1.4% to 3.8% increase in bending strength of joists with an allowable bending strength of 1000 psi. More testing is indicated to resolve this discrepancy between laboratory results and analytical modeling results. In addition to elucidating nonlinear partial composite behavior of existing roof systems, this paper shows that, with minor changes in roof framing practices, strength increases of 70% or more are achievable, compared to the strengths of conventionally sheathed joists.

  16. A fuzzy approach to selecting roof supports in longwall mining

    Directory of Open Access Journals (Sweden)

    Yetkin, M. E.

    2016-05-01

    Full Text Available As a decision-making problem, selecting proper machines and equipment plays a key role for mining sites and companies. Many factors affect this decision, and values belonging to these factors can be expressed numerically and/or non-numerically. In order to make the most appropriate decision, engineers must carry out an evaluation process that comprises all criteria that might affect decision-making. To achieve this, multi-criteria decision-making tools are used. As a result of technological developments, coal outputs in longwall mining have risen tremendously over the last decades, and longwall mechanisation has become unavoidable. The significance of powered roof supports in particular increases day- by-day, since the rate of roof support has to be in accordance with the rate of face advance in longwalls. In this study, an integrated fuzzy analytic hierarchy process and fuzzy goal programming model is used to select the most suitable powered roof supports. The procedure is applied to a real-life underground coal mine that is operated using the longwall method. Seven alternative powered roof supports are compared with each other, taking a total of 24 decision criteria under four main topics into account. In conclusion, the most suitable roof supports for the mine under study are determined and recommended to the decision-makers of the system.

  17. The green roof dilemma - discussion of Francis and Lorimer (2011).

    Science.gov (United States)

    Henry, Alexandre; Frascaria-Lacoste, Nathalie

    2012-08-15

    Urban ecosystems are the most complex mosaics of vegetative land cover that can be found. In a recent paper, Francis and Lorimer (2011) evaluated the reconciliation potential of living roofs and walls. For these authors, these two techniques for habitat improvement have strong potential for urban reconciliation ecology. However they have some ecological and societal limitations such as the physical extreme environmental characteristics, the monetary investment and the cultural perceptions of urban nature. We are interested in their results and support their conclusions. However, for a considerable time, green roofs have been designed to provide urban greenery for buildings and the green roof market has only focused on extensive roof at a restricted scale within cities. Thus, we have strong doubts about the relevance of their use as possible integrated elements of the network. Furthermore, without dynamic progress in research and the implementation of well-thought-out policies, what will be the real capital gain from green roofs with respect to land-use complementation in cities? If we agree with Francis and Lorimer (2011) considering that urban reconciliation ecology between nature and citizens is a current major challenge, then "adaptive collaborative management" is a fundamental requirement.

  18. A New Kind of Roof Greening System in China

    Institute of Scientific and Technical Information of China (English)

    2015-01-01

    With the wider use of green roofs, new technology and new materials are being applied to the field of building roof greening forbuildings. This paper introduces BRGS (built- up roof greening system), a new type of roof greening system that differs from roofgreening systems currently used in China in that it integrates a main and an auxiliary water storage capacity into the roof greeningsystem. Compared to other systems currently in use, BRGS offers a simpler, quicker, less labor intensive construction process;lighter floor load; and lower long term maintenance requirements and costs. It also makes full use of rainwater and snowmelt,which provides a significant amount of water to plants. This paper also introduces a planting experiment, the results of whichindicate that plants during their early stages of growth tolerate an alkaline environment, and that after a period of time, the pHvalue level of water stored in BRGS approaches 8.3, so we can conclude that BRGS is suitable for construction engineering.

  19. Numerical simulation of flows around long-span flat roof

    Institute of Scientific and Technical Information of China (English)

    SUN Xiao-ying; WU Yue; SHEN Shi-zhao

    2005-01-01

    Long-span roof with span larger than height always has a complicated three-dimensional curve. Wind pressure on the roof is often influenced not only by the atmospheric turbulence, but also by the "signature" turbulence provoked in the wind by the structure itself. So it is necessary to study characteristics of flows around the roof. In this paper, three-dimensional numerical simulation of wind-induced pressure has been performed on a long-span flat roof by means of Computational Fluid Dynamics (CFD) software--FLUENT. The flow characteristics are studied by considering some parameters, such as wind direction, span-height ratio, roof pitch, flow characteristics, roughness of terrain. The simulation is based upon the Reynolds-averaged equations, in which Reynolds stress equation model (RSM) and SIMPLE technology (Semi-Implicit Method for Pressure-Linked Equations) have been used. Compared with wind tunnel tests, the computational results have good agreement with the experimental data. It is proved that the results are creditable and the method is feasible.

  20. Retention performance of green roofs in three different climate regions

    Science.gov (United States)

    Sims, Andrew W.; Robinson, Clare E.; Smart, Charles C.; Voogt, James A.; Hay, Geoffrey J.; Lundholm, Jeremey T.; Powers, Brandon; O'Carroll, Denis M.

    2016-11-01

    Green roofs are becoming increasingly popular for moderating stormwater runoff in urban areas. This study investigated the impact different climates have on the retention performance of identical green roofs installed in London Ontario (humid continental), Calgary Alberta (semi-arid, continental), and Halifax Nova Scotia (humid, maritime). Drier climates were found to have greater percent cumulative stormwater retention with Calgary (67%) having significantly better percent retention than both London (48%) and Halifax (34%). However, over the same study period the green roof in London retained the greatest depth of stormwater (598 mm), followed by the green roof in Halifax (471 mm) and then Calgary (411 mm). The impact of climate was largest for medium sized storms where the antecedent moisture condition (AMC) at the beginning of a rainfall event governs retention performance. Importantly AMC was a very good predictor of stormwater retention, with similar retention at all three sites for a given AMC, emphasizing that AMC is a relevant indicator of retention performance in any climate. For large rainfall events (i.e., >45 mm) green roof average retention ranged between 16% and 29% in all cities. Overall, drier climates have superior retention due to lower AMC in the media. However, moderate and wet climates still provide substantial total volume reduction benefits.

  1. Computational analysis of aircraft pressure relief doors

    Science.gov (United States)

    Schott, Tyler

    Modern trends in commercial aircraft design have sought to improve fuel efficiency while reducing emissions by operating at higher pressures and temperatures than ever before. Consequently, greater demands are placed on the auxiliary bleed air systems used for a multitude of aircraft operations. The increased role of bleed air systems poses significant challenges for the pressure relief system to ensure the safe and reliable operation of the aircraft. The core compartment pressure relief door (PRD) is an essential component of the pressure relief system which functions to relieve internal pressure in the core casing of a high-bypass turbofan engine during a burst duct over-pressurization event. The successful modeling and analysis of a burst duct event are imperative to the design and development of PRD's to ensure that they will meet the increased demands placed on the pressure relief system. Leveraging high-performance computing coupled with advances in computational analysis, this thesis focuses on a comprehensive computational fluid dynamics (CFD) study to characterize turbulent flow dynamics and quantify the performance of a core compartment PRD across a range of operating conditions and geometric configurations. The CFD analysis was based on a compressible, steady-state, three-dimensional, Reynolds-averaged Navier-Stokes approach. Simulations were analyzed, and results show that variations in freestream conditions, plenum environment, and geometric configurations have a non-linear impact on the discharge, moment, thrust, and surface temperature characteristics. The CFD study revealed that the underlying physics for this behavior is explained by the interaction of vortices, jets, and shockwaves. This thesis research is innovative and provides a comprehensive and detailed analysis of existing and novel PRD geometries over a range of realistic operating conditions representative of a burst duct over-pressurization event. Further, the study provides aircraft

  2. Failure case of a garage door opener

    Directory of Open Access Journals (Sweden)

    Habib, K.

    2005-12-01

    Full Text Available A failure analysis of a garage door opener was conducted for determination of the cause of the failure. The analysis included visual inspections of broken parts as well as electron microscopy examinations of the fracture surface. The visual inspections showed that a bolt connected to the inner trolley of the garage opener assembly was initially fractured. Also, the results of electron microscopy examinations revealed that the broken bolt failed by fatigue damage phenomenon, due to alternating torsional stresses throughout 25 years of an operational life of the garage opener. In addition, a mathematical model corresponding to the failure mechanism was derived along the failure analysis. The model comprises of both design philosophy and fracture mechanics approaches.

    Se analizó el fallo del mecanismo de apertura de una puerta de garaje con el fin de determinar sus causas. El análisis incluyó una inspección visual de las piezas rotas así como un examen mediante microscopía de la superficie de fractura. La inspección visual reveló que primero se fracturó un perno conectado al carro interior del mecanismo de apertura. Los resultados del análisis por microscopía electrónica también mostraron que el perno roto falló debido a fenómenos de daño por fatiga, debido a los esfuerzos torsionales alternos a la largo de 25 años de vida en servicio del mecanismo de apertura. Por otra parte, se construyó un modelo matemático correspondiente al mecanismo de rotura durante el análisis del mismo. Este modelo comprende enfoques, tanto de la filosofía de diseño como de la mecánica de fractura.

  3. Displacement, stress and seismicity in roadway roofs during mining-induced failure

    Energy Technology Data Exchange (ETDEWEB)

    Shen, B.; King, A.; Guo, H. [CSIRO Exploration & Mining, Kenmore, Qld. (Australia)

    2008-07-15

    Roof stability in gateroads is a long-standing issue in many of the underground mines in Australia that use longwall extraction methods, due primarily to a significant increase of vertical stresses ahead of the longwall face. Although numerous studies have been done in the past, the process of roof rock deformation and breakage prior to and during a roof failure in an actual mining environment is still being debated. This paper describes a new integrated roof monitoring system and the results from applying this system in an Australian underground coal mine. The system integrates displacement, stress and seismic monitoring. It has been applied to two roadways in an Australian underground coal mine during two field experiments. The key roof behaviour identified by the integrated monitoring package during the two field monitoring experiments is reported and discussed in this paper. The experiments were conducted in the 'tailgate' roadways that are adjacent to the caved zone, or 'goaf', of the previously mined panels. It was found in the experiments that, prior to roof falls, roof displacement accelerates whereas the horizontal stresses reduce. Seismic activity intensifies before major roof displacement or stress changes are evident, and subsides in the later stage of roof failure when large roof displacement is visible. The seismic resonance frequencies decrease during roof failure development. The field monitoring studies have also identified a number of quantitative and site-specific roof fall precursors potentially useful for roof fall prediction and prevention.

  4. Pneumatic vs. door-to-door waste collection systems in existing urban areas: a comparison of economic performance.

    Science.gov (United States)

    Teerioja, Nea; Moliis, Katja; Kuvaja, Eveliina; Ollikainen, Markku; Punkkinen, Henna; Merta, Elina

    2012-10-01

    Pneumatic waste collection systems are becoming increasingly popular in new urban residential areas, and an attractive alternative to conventional vehicle-operated municipal solid waste (MSW) collection also in ready-built urban areas. How well pneumatic systems perform in ready-built areas is, however, an unexplored topic. In this paper, we analyze how a hypothetical stationary pneumatic waste collection system compares economically to a traditional vehicle-operated door-to-door collection system in an existing, densely populated urban area. Both pneumatic and door-to-door collection systems face disadvantages in such areas. While buildings and fixed city infrastructure increase the installation costs of a pneumatic system in existing residential areas, the limited space for waste transportation vehicles and containers cause problems for vehicle-operated waste collection systems. The method used for analyzing the cost effects of the compared waste collection systems in our case study takes into account also monetized environmental effects of both waste collection systems. As a result, we find that the door-to-door collection system is economically almost six times more superior. The dominant cost factor in the analysis is the large investment cost of the pneumatic system. The economic value of land is an important variable, as it is able to reverse the results, if the value of land saved with a pneumatic system is sufficiently high. Copyright © 2012 Elsevier Ltd. All rights reserved.

  5. Requirements of inverted roofs with a drainage layer

    DEFF Research Database (Denmark)

    Leimer, Hans-Peter; Rode, Carsten; Künzel, Hartwig

    2005-01-01

    flowing between the insulation and the waterproofing membrane. It is possible to calculate the extra heat loss of inverted roofs caused by rain water below the heat insulation. The extra heat loss depends on the average rainfall and on which fraction of the rain water that will drain between...... the waterproofing membrane and the thermal insulation. This paper explains the application of the standard for areas of Europe. Furthermore, some constructions are proposed, which have such small extra heat losses caused by rain water that they may be disregarded in the calculation.......This contribution illustrates the application of the standard EN ISO 6946 regarding the heat loss of an inverted roof for different regions of Europe. An addendum to the standard (EN ISO 6946:1996/A1, 2003) introduces a correction to the thermal transmittance of inverted roofs due to rain water...

  6. Plant functional traits predict green roof ecosystem services.

    Science.gov (United States)

    Lundholm, Jeremy; Tran, Stephanie; Gebert, Luke

    2015-02-17

    Plants make important contributions to the services provided by engineered ecosystems such as green roofs. Ecologists use plant species traits as generic predictors of geographical distribution, interactions with other species, and ecosystem functioning, but this approach has been little used to optimize engineered ecosystems. Four plant species traits (height, individual leaf area, specific leaf area, and leaf dry matter content) were evaluated as predictors of ecosystem properties and services in a modular green roof system planted with 21 species. Six indicators of ecosystem services, incorporating thermal, hydrological, water quality, and carbon sequestration functions, were predicted by the four plant traits directly or indirectly via their effects on aggregate ecosystem properties, including canopy density and albedo. Species average height and specific leaf area were the most useful traits, predicting several services via effects on canopy density or growth rate. This study demonstrates that easily measured plant traits can be used to select species to optimize green roof performance across multiple key services.

  7. Choosing the right green roof media for water quality

    Energy Technology Data Exchange (ETDEWEB)

    Hunt, W.F.; Hathaway, A.M.; Smith, J.T.; Calabria, J. [North Carolina State Univ., Raleigh, NC (United States). Dept. of Biological and Agricultural Engineering

    2006-07-01

    Due to the large concentrations of a variety of contaminants entering streams and rivers, stormwater is a significant contributor to the impairment of North Carolina (NC) waters. Pollutants range from pesticides and nutrients to oils and petroleum products to construction chemicals and sediment which are evident in fish kills, contamination of drinking water supplies, and deterioration of wildlife habitats. One of the major tools to improve storm water quality are stormwater best management practices (BMPs). BMPs include bioretention areas, wet and dry detention ponds, constructed wetlands, and sand filters. One option for urban BMPs is the green roof which uses rooftop square footage that would not otherwise be available on the ground. A research project was conducted that tests two field green roofs in Raleigh and Asheville, NC. In addition, a laboratory test was conducted in 2004 and a plot study of three designer media was conducted in 2005 on the NC State University Campus in Raleigh, NC. The objectives of the research were to examine how different green roof media reduce concentrations of nitrogen and phosphorus, if the leaching rate of nitrogen and phosphorus from soil media of field green roofs decrease with time, and to determine whether green roofs can be used as nutrient reduction BMPs. This paper provided background information on previous green roof stormwater research, discussed each of the sites chosen for the study in detail and presented the field monitoring process and laboratory study methodology. This was followed by a detailed examination of the results. It was concluded that an optimal soil media can be established that balances plant growth with water quality and quantity control. 16 refs., 2 tabs., 8 figs.

  8. INFINITE ELEMENT METHOD FOR THE EXTERIOR PROBLEMS OF THE HELMHOLTZ EQUATIONS

    Institute of Scientific and Technical Information of China (English)

    Lung-an Ying

    2000-01-01

    There are two cases of the exterior problems of the Helmholtz equation. If λ > 0 the bilinear form is coercive, and if λ < 0 it is the scattering problem.We give a new approach of the infinite element method, which enables us to solve these exterior problems as well as corner problems. A numerical example of the scattering problem is given.

  9. Field Testing Unvented Roofs with Asphalt Shingles in Cold and Hot-Humid Climates

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, Kohta [Building Science Corporation, Westford, MA (United States); Lstiburek, Joseph W. [Building Science Corporation, Westford, MA (United States)

    2015-09-01

    Test houses with unvented roof assemblies were built to measure long-term moisture performance, in the Chicago area (5A) and the Houston area (2A). The Chicago-area test bed had seven experimental rafter bays, including a control vented compact roof, and six unvented roof variants with cellulose or fiberglass insulation. The interior was run at 50% RH. The Houston-area roof was an unvented attic insulated with spray-applied fiberglass. Most ridges and hips were built with a diffusion vent detail, capped with vapor permeable roof membrane. In contrast, the diffusion vent roofs had drier conditions at the roof peak in wintertime, but during the summer, RHs and MCs were higher than the unvented roof (albeit in the safe range).

  10. Damage to thermal insulation foams in low-slope roof systems caused by simulated foot traffic

    National Research Council Canada - National Science Library

    Liu, Karen K; Booth, R. J

    1999-01-01

    The results indicated that common.ly used foam plastic roof insulations will be damaged if exposed to foot traffic, and that their protection with fibrous overlay boards as recommended by roofing contractor associations continues...

  11. Extraction of Roof Lines from High-Resolution Images by a Grouping Method

    Science.gov (United States)

    Dal Poz, A. P.; Fernandes, V. J. M.

    2016-06-01

    This paper proposes a method for extracting groups of straight lines that represent roof boundaries and roof ridgelines from highresolution aerial images using corresponding Airborne Laser Scanner (ALS) roof polyhedrons as initial approximations. The proposed method is based on two main steps. First, straight lines that are candidates to represent roof ridgelines and roof boundaries of a building are extracted from the aerial image. Second, a group of straight lines that represent roof boundaries and roof ridgelines of a selected building is obtained through the optimization of a Markov Random Field (MRF)-based energy function using the genetic algorithm optimization method. The formulation of this energy function considers several attributes, such as the proximity of the extracted straight lines to the corresponding projected ALS-derived roof polyhedron and the rectangularity (extracted straight lines that intersect at nearly 90°). Experimental results are presented and discussed in this paper.

  12. Asia Central en la política exterior rusa

    Directory of Open Access Journals (Sweden)

    Javier Morales

    2012-01-01

    Full Text Available Las políticas rusas hacia Asia Central han estado condicionadas por la herencia histórica anterior a la disolución de la URSS, pero también por los cambios en el sistema internacional y en la propia Rusia acaecidos desde entonces. ¿En qué medida la actuación de Rusia ha sido coherente y estable, basada en una estrategia para Asia Central fundamentada en los intereses nacionales? En este artículo examinamos los fundamentos de la política exterior rusa en relación con Asia Central, dividiéndola en tres apartados: político, económico y de seguridad.

  13. Dimensión social de la publicidad exterior

    Directory of Open Access Journals (Sweden)

    Lic. Marta Pacheco Rueda

    1998-01-01

    Full Text Available La publicidad exterior moderna nace en España a principios de los años 60, en un período en que desde el gobierno se acomete una serie de iniciativas tendentes a reactivar la economía del país. La incipiente apertura económica no es desaprovechada por grandes firmas internacionales que aumentan sus inversiones e introducen en el mercado español productos con una larga tradición de consumo en los países occidentales industrializados. Se produce el asentamiento definitivo de las agencias multinacionales de publicidad, de procedencia norteamericana sobre todo, que traen consigo técnicas que responden a una filosofía de marketing, término que si en aquel momento resulta un tanto extraño, con el paso de los años se convierte en un vocablo de uso extendido.

  14. Relaciones exteriores de la Unión Europea

    OpenAIRE

    González Fernández, Sara; Ruiz, Pablo

    1998-01-01

    Distintos estudios sobre las relaciones económicas externas de la Unión Europea a través de tres apartados: una Introducción sobre el propio proceso de integración; Análisis sectorial de las políticas coumunes de agricultura, medio ambiente, cooperación para el desarrollo, política exterior y seguridad común y un tercer bloque sobre el Análisis geográfico de las relaciones comerciales con América Latina, Europa Central y Oriental, la política mediterránea y asiática y las relaciones con los p...

  15. Single-Sided Natural Ventilation through a Velux Roof Window

    DEFF Research Database (Denmark)

    Li, Zhigang; Nielsen, Peter Vilhelm; Fransson, J.

    2004-01-01

    This paper investigates the single-sided natural ventilation through a VELUX centre pivot roof window under natural weather conditions. The aim of the investigation is to develop an empirical formulation for air flow rate through a roof window based on CFD and tracer gas decay measurement methods....... CFD can separate buoyancy and wind effects in the calculation of the air flow rate through a window opening, but it is difficult to isolate wind effect from buoyancy forces during measurements. The ?Warren-plot? method can be used to separate and analyse the measured data which are dominated by stack...

  16. Modelling of green roof hydrological performance for urban drainage applications

    Science.gov (United States)

    Locatelli, Luca; Mark, Ole; Mikkelsen, Peter Steen; Arnbjerg-Nielsen, Karsten; Bergen Jensen, Marina; Binning, Philip John

    2014-11-01

    Green roofs are being widely implemented for stormwater management and their impact on the urban hydrological cycle can be evaluated by incorporating them into urban drainage models. This paper presents a model of green roof long term and single event hydrological performance. The model includes surface and subsurface storage components representing the overall retention capacity of the green roof which is continuously re-established by evapotranspiration. The runoff from the model is described through a non-linear reservoir approach. The model was calibrated and validated using measurement data from 3 different extensive sedum roofs in Denmark. These data consist of high-resolution measurements of runoff, precipitation and atmospheric variables in the period 2010-2012. The hydrological response of green roofs was quantified based on statistical analysis of the results of a 22-year (1989-2010) continuous simulation with Danish climate data. The results show that during single events, the 10 min runoff intensities were reduced by 10-36% for 5-10 years return period and 40-78% for 0.1-1 year return period; the runoff volumes were reduced by 2-5% for 5-10 years return period and 18-28% for 0.1-1 year return period. Annual runoff volumes were estimated to be 43-68% of the total precipitation. The peak time delay was found to greatly vary from 0 to more than 40 min depending on the type of event, and a general decrease in the time delay was observed for increasing rainfall intensities. Furthermore, the model was used to evaluate the variation of the average annual runoff from green roofs as a function of the total available storage and vegetation type. The results show that even a few millimeters of storage can reduce the mean annual runoff by up to 20% when compared to a traditional roof and that the mean annual runoff is not linearly related to the storage. Green roofs have therefore the potential to be important parts of future urban stormwater management plans.

  17. Retention performance of green roofs in representative climates worldwide

    Science.gov (United States)

    Viola, F.; Hellies, M.; Deidda, R.

    2017-10-01

    The ongoing process of global urbanization contributes to an increase in stormwater runoff from impervious surfaces, threatening also water quality. Green roofs have been proved to be innovative stormwater management measures to partially restore natural states, enhancing interception, infiltration and evapotranspiration fluxes. The amount of water that is retained within green roofs depends not only on their depth, but also on the climate, which drives the stochastic soil moisture dynamic. In this context, a simple tool for assessing performance of green roofs worldwide in terms of retained water is still missing and highly desirable for practical assessments. The aim of this work is to explore retention performance of green roofs as a function of their depth and in different climate regimes. Two soil depths are investigated, one representing the intensive configuration and another representing the extensive one. The role of the climate in driving water retention has been represented by rainfall and potential evapotranspiration dynamics. A simple conceptual weather generator has been implemented and used for stochastic simulation of daily rainfall and potential evapotranspiration. Stochastic forcing is used as an input of a simple conceptual hydrological model for estimating long-term water partitioning between rainfall, runoff and actual evapotranspiration. Coupling the stochastic weather generator with the conceptual hydrological model, we assessed the amount of rainfall diverted into evapotranspiration for different combinations of annual rainfall and potential evapotranspiration in five representative climatic regimes. Results quantified the capabilities of green roofs in retaining rainfall and consequently in reducing discharges into sewer systems at an annual time scale. The role of substrate depth has been recognized to be crucial in determining green roofs retention performance, which in general increase from extensive to intensive settings. Looking at the

  18. Roof collapse of shallow tunnels with limit analysis method

    Institute of Scientific and Technical Information of China (English)

    YANG Xiao-li; LONG Ze-xiang

    2015-01-01

    A new failure mechanism is proposed to analyze the roof collapse based on nonlinear failure criterion. Limit analysis approach and variational principle are used to obtain analytical findings concerning the stability of potential roof. Then, parametric study is carried out to derive the change rule of corresponding parameters on the influence of collapsing shape, which is of paramount engineering significance to instruct the tunnel excavations. In comparison with existing results, the findings show agreement and validity of the proposed method. The actual collapse in certain shallow tunnels is well in accordance with the proposed failure mechanism.

  19. Crystalline roof glazing - Westside shopping centre, Berne; Kristalline Dachverglasungen

    Energy Technology Data Exchange (ETDEWEB)

    Enkerli, W.

    2009-07-01

    This illustrated article takes a look at the new shopping and leisure centre on the western outskirts of Berne, Switzerland. In particular, the roof of this unusual building over the motorway with its sloping walls and zig-zag design is looked at. The centre's shopping mall, adventure baths and spa, a multiplex cinema, an old peoples' home and a hotel are briefly discussed, as is the embedding of the centre in its suburban environment. The roof construction with its crystalline skylights is examined and discussed in detail. The centre's building technical services are also briefly commented on.

  20. Digging the New York City Skyline: soil fungal communities in green roofs and city parks.

    Science.gov (United States)

    McGuire, Krista L; Payne, Sara G; Palmer, Matthew I; Gillikin, Caitlyn M; Keefe, Dominique; Kim, Su Jin; Gedallovich, Seren M; Discenza, Julia; Rangamannar, Ramya; Koshner, Jennifer A; Massmann, Audrey L; Orazi, Giulia; Essene, Adam; Leff, Jonathan W; Fierer, Noah

    2013-01-01

    In urban environments, green roofs provide a number of benefits, including decreased urban heat island effects and reduced energy costs for buildings. However, little research has been done on the non-plant biota associated with green roofs, which likely affect their functionality. For the current study, we evaluated whether or not green roofs planted with two native plant communities in New York City functioned as habitats for soil fungal communities, and compared fungal communities in green roof growing media to soil microbial composition in five city parks, including Central Park and the High Line. Ten replicate roofs were sampled one year after planting; three of these roofs were more intensively sampled and compared to nearby city parks. Using Illumina sequencing of the fungal ITS region we found that green roofs supported a diverse fungal community, with numerous taxa belonging to fungal groups capable of surviving in disturbed and polluted habitats. Across roofs, there was significant biogeographical clustering of fungal communities, indicating that community assembly of roof microbes across the greater New York City area is locally variable. Green roof fungal communities were compositionally distinct from city parks and only 54% of the green roof taxa were also found in the park soils. Phospholipid fatty acid analysis revealed that park soils had greater microbial biomass and higher bacterial to fungal ratios than green roof substrates. City park soils were also more enriched with heavy metals, had lower pH, and lower quantities of total bases (Ca, K, and Mg) compared to green roof substrates. While fungal communities were compositionally distinct across green roofs, they did not differentiate by plant community. Together, these results suggest that fungi living in the growing medium of green roofs may be an underestimated component of these biotic systems functioning to support some of the valued ecological services of green roofs.

  1. Digging the New York City Skyline: soil fungal communities in green roofs and city parks.

    Directory of Open Access Journals (Sweden)

    Krista L McGuire

    Full Text Available In urban environments, green roofs provide a number of benefits, including decreased urban heat island effects and reduced energy costs for buildings. However, little research has been done on the non-plant biota associated with green roofs, which likely affect their functionality. For the current study, we evaluated whether or not green roofs planted with two native plant communities in New York City functioned as habitats for soil fungal communities, and compared fungal communities in green roof growing media to soil microbial composition in five city parks, including Central Park and the High Line. Ten replicate roofs were sampled one year after planting; three of these roofs were more intensively sampled and compared to nearby city parks. Using Illumina sequencing of the fungal ITS region we found that green roofs supported a diverse fungal community, with numerous taxa belonging to fungal groups capable of surviving in disturbed and polluted habitats. Across roofs, there was significant biogeographical clustering of fungal communities, indicating that community assembly of roof microbes across the greater New York City area is locally variable. Green roof fungal communities were compositionally distinct from city parks and only 54% of the green roof taxa were also found in the park soils. Phospholipid fatty acid analysis revealed that park soils had greater microbial biomass and higher bacterial to fungal ratios than green roof substrates. City park soils were also more enriched with heavy metals, had lower pH, and lower quantities of total bases (Ca, K, and Mg compared to green roof substrates. While fungal communities were compositionally distinct across green roofs, they did not differentiate by plant community. Together, these results suggest that fungi living in the growing medium of green roofs may be an underestimated component of these biotic systems functioning to support some of the valued ecological services of green roofs.

  2. Using ground penetrating radar for roof hazard detection in underground mines. Report of investigations/1996

    Energy Technology Data Exchange (ETDEWEB)

    Molinda, G.M.; Monaghan, W.D.; Mowrey, G.L.; Persetic, G.F.

    1996-08-01

    Ground penetrating radar (GPR) is being investigated for the potential to determine roof hazards in underground mines. GPR surveys were conducted at four field sites with accompanying ground truth in order to determine the value of GPR for roof hazard detection. The resolution of the current system allows detection of gross roof fractures (>1/4 in zone) or rider beds in coal measure roof. Differences in data quality are discussed, as well as suggestions for collecting improved data.

  3. System for monitoring of green roof performance: use of weighing roof segment and non-invasive visualization

    Science.gov (United States)

    Jelinkova, Vladmira; Dohnal, Michal; Picek, Tomas; Sacha, Jan

    2015-04-01

    Understanding the performance of technogenic substrates for green roofs is a significant task in the framework of sustainable urban planning and water/energy management. The potential retention and detention of the anthropogenic, light weight soil systems and their temporal soil structure changes are of major importance. A green roof test segment was built to investigate the benefits of such anthropogenic systems. Adaptable low-cost system allows long-term monitoring of preferred characteristics. Temperature and water balance measurements complemented with meteorological observations and knowledge of physical properties of the substrates provide basis for detailed analysis of thermal and hydrological regime in green roof systems. The first results confirmed the benefits of green roof systems. The reduction of temperature fluctuations as well as rainfall runoff was significant. Depending on numerous factors such substrate material or vegetation cover the test green roof suppressed the roof temperature amplitude for the period analyzed. The ability to completely prevent (light rainfall events) or reduce and delay (medium and heavy rainfall events) the peak runoff was also analyzed. Special attention is being paid to the assessment of soil structural properties related to possible aggregation/disaggregation, root growth, weather conditions and associated structural changes using non-invasive imaging method. X-ray computed microtomography of undisturbed soil samples (taken from experimental segments) is used for description of pore space geometry, evaluation of surface to volume ratio, additionally for description of cracks and macropores as a product of soil flora and fauna activity. The information from computed tomography imaging will be used for numerical modeling of water flow in variable saturated porous media. The research was realized as a part of the University Centre for Energy Efficient Buildings supported by the EU and with financial support from the Czech

  4. 40 CFR 443.30 - Applicability; description of the asphalt roofing subcategory.

    Science.gov (United States)

    2010-07-01

    ... asphalt roofing subcategory. 443.30 Section 443.30 Protection of Environment ENVIRONMENTAL PROTECTION... MATERIALS (TARS AND ASPHALT) POINT SOURCE CATEGORY Asphalt Roofing Subcategory § 443.30 Applicability; description of the asphalt roofing subcategory. The provisions of this subpart are applicable to...

  5. Who governs climate adaptation? Getting green roofs for stormwater retention off the ground

    NARCIS (Netherlands)

    Mees, H.L.P.; Driessen, P.P.J.; Runhaar, H.A.C.; Stamatelos, J.

    2013-01-01

    Green roofs are an innovative solution for urban stormwater management. This paper examines governance arrangements for green roofs as a ‘no-regrets’ climate adaptation measure in five cities. We analysed who governs green roofs, why and with what outcome. Our results show that hierarchical and mark

  6. Effect of green roofs on air temperature; measurement study of well-watered and dry conditions

    Science.gov (United States)

    Solcerova, Anna; van de Ven, Frans; Wang, Mengyu; van de Giesen, Nick

    2016-04-01

    Rapid urbanization and increasing number and duration of heat waves poses a need for understanding urban climate and ways to mitigate extremely high temperatures. One of repeatedly suggested and often investigated methods to moderate the so called urban heat island are green roofs. This study investigates several extensive green roofs in Utrecht (NL) and their effect on air temperature right above the roof surface. Air temperature was measured 15 and 30 cm above the roof surface and also in the substrate. We show that under normal condition is air above green roof, compared to white gravel roof, colder at night and warmer during day. This suggest that green roofs might help decrease air temperatures at night, when the urban heat island is strongest, but possibly contribute to high temperatures during daytime. We also measured situation when the green roofs wilted and dried out. Under such conditions green roof exhibits more similar behavior to conventional white gravel roof. Interestingly, pattern of soil temperature remains almost the same for both dry and well-prospering green roof, colder during day and warmer at night. As such, green roof works as a buffer of diurnal temperature changes.

  7. Potential benefits of plant diversity on vegetated roofs: a literature review.

    Science.gov (United States)

    Cook-Patton, Susan C; Bauerle, Taryn L

    2012-09-15

    Although vegetated green roofs can be difficult to establish and maintain, they are an increasingly popular method for mitigating the negative environmental impacts of urbanization. Most green roof development has focused on maximizing green roof performance by planting one or a few drought-tolerant species. We present an alternative approach, which recognizes green roofs as dynamic ecosystems and employs a diversity of species. We draw links between the ecological and green roof literature to generate testable predictions about how increasing plant diversity could improve short- and long-term green roof functioning. Although we found few papers that experimentally manipulated diversity on green roofs, those that did revealed ecological dynamics similar to those in more natural systems. However, there are many unresolved issues. To improve overall green roof performance, we should (1) elucidate the links among plant diversity, structural complexity, and green roof performance, (2) describe feedback mechanisms between plant and animal diversity on green roofs, (3) identify species with complementary traits, and (4) determine whether diverse green roof communities are more resilient to disturbance and environmental change than less diverse green roofs.

  8. Wind loads on stand-off photovoltaic systems on pitched roofs

    NARCIS (Netherlands)

    Geurts, C.P.W.; Blackmore, P.

    2013-01-01

    Stand-off photovoltaic systems are a popular measure for retrofitting of existing pitched roofs.Panels are generally mounted parallel to the existing roof coverings,usually roofing tiles.Full scale and wind tunnel experiments have been performed to determine the net uplift loads on these systems, wh

  9. Evaluation of Green Roof Water Quantity and Quality Performance in an Urban Climate

    Science.gov (United States)

    In this report we present an analysis of water benefits from an array of observed green roof and control (non-vegetated) roof project sites throughout NYC. The projects are located on a variety of building sites and represent a diverse set of available extensive green roof instal...

  10. Evaluation of Green Roof Plants and Materials for Semi-Arid Climates

    Science.gov (United States)

    Abstract While green roof systems have proven to be highly effective in the evaporative cooling of buildings, reduction of roof top temperatures, protection of roof membranes from solar radiation degradation, reducing stormwater runoff, as well as beautification of the urban roo...

  11. Green Roofs: A Part of Green Infrastructure Strategy for Urban Areas

    Science.gov (United States)

    This is a presentation on the basics of green roof technology. The presentation highlights some of the recent ORD research projects on green roofs and provides insight for the end user as to the benefits for green roof technology. It provides links to currently available EPA rep...

  12. Analysis of mechanical behaviors of big pipe roof for shallow buried large-span tunnel

    Institute of Scientific and Technical Information of China (English)

    Li Jian; Tan Zhongsheng; Yu Yu; Guo Xiaohong

    2013-01-01

    A series of researches on mechanical behaviors of big pipe roof for shallow large-span loess tunnel were carried out based on the Wenxiang tunnel in Zhengzhou-Xi’an Special Passenger Railway. The longitudinal de-formations of the pipe roofs were monitored and the mechanical behaviors of the pipe roofs were analyzed at the test section. A new double-parameter elastic foundation beam model for pipe roof in shallow tunnels was put for-ward in Wenxiang tunnel. The measured values and the calculation results agreed well with each other,revealing the force-deformation law of big pipe roof in loess tunnel:At about 15 m in front of the excavating face,the pipe roof starts to bear the load;at about 15 m behind the excavating face,the force of the pipe roof tends to be stabi-lized;the longitudinal deformation of the whole pipe roofs is groove-shaped distribution,and the largest force of pipe roofs is at the excavating face. Simultaneously,the results also indicate that mechanical behaviors of pipe roof closely relate to the location of the excavation face,the footage of the tunnelling cycle and the mechanics pa-rameters of pipe roof and rock. The conclusions can be reference for the design parameter optimization and the con-struction scheme selection of pipe roofs,and have been verified by the result of numerical analysis software FLAC3D and deformation monitoring.

  13. SAFETY BULLETIN TIS 2002-03 GLASS DOORS

    CERN Multimedia

    2002-01-01

    Be careful! What happened?   Unsignaled reinforced glass.   Signaled safety glass.   A visitor recently hurt his leg when he walked into a glass door which shattered from the impact. This door was made of reinforced glass, a material which is inappropriate for this kind of use as it is too fragile. Indeed, it shatters into sharp splinters which can cause serious injury. Furthermore, the door was not easily visible (badly lit, no warning signs, ...). Corrective measures Just after the accident: glass doors were signed to make them more visible; replacement of dangerous glass panes planned for 2003. What preventive measures can be taken against this kind of accident? If you are in charge of projects and works: In the call for tender, specify the acceptable shock resistance level of the glass pane; Before the door is mounted, insist on receiving technical documentation and/or certificate of conformity from the supplier; If in doubt, ask advice from the TIS/GS sa...

  14. Design and Development of Sound Control Door Lock System

    Directory of Open Access Journals (Sweden)

    Elechi Promise

    2015-09-01

    Full Text Available Security is very important, especially the security of lives and properties. This work involves the use of sound in controlling the opening and closing of doors using electromechanical application. In this work, sound is used to activate the mechanisms which opens and closes the door without any external effort. The system is made up of two main features, the Security Access system and Control Mechanism. The security access system was designed using circuit wizard software and then constructed on a veroboard and other materials while the control mechanism was constructed using a simple DC motor for the opening and closing of the door. In its operation, a specific sound pattern in form of a positive voltage is sent to pin 14 of IC1, pin 14 of IC1 is connected to a transistor(Q2 which causes the 555timer to oscillate sending pulses to pin 14 of IC2, during this, the output of IC2 then operates in a sequential mode. The code switch then sets the number of beat that will set IC3 into the desire sequential output set by the operator. The output signal energizes the relay which controls the DC motor to open the door and closes after a preset time.The testing showed quick and fast response in operation of the door lock system.

  15. Thermally insulating green roof with model function. Roof gardens gain acceptance; Waermedaemmendes Gruendach mit Vorbildfunktion. Dachbegruenung macht Schule

    Energy Technology Data Exchange (ETDEWEB)

    Appl, Roland [ZinCo GmbH, Unterensingen (Germany)

    2010-07-01

    The new built consolidated school for physically disabled and speech handicapped persons in the Swabian Dettingen/Teck (Federal Republic of Germany) has a model function in every sense. This school provides a space for the promotion and personal development for more than 120 pupils from the region around Kirchheim (Federal Republic of Germany). In addition, a kindergarten for speech handicapped infants is integrated. The school is future-oriented and exemplary not only in its function, but also in its outside form. Wood as a naturally grown building material covers the fronts, and plants decorate the roofs. The heat insulating roof planting makes a substantial contribution to the structural thermal protection.

  16. Improving Door-to-balloon Time by Decreasing Door-to-ECG time for Walk-in STEMI Patients

    Directory of Open Access Journals (Sweden)

    Coyne, Christopher J.

    2014-12-01

    Full Text Available Introduction: The American Heart Association/American College of Cardiology guidelines recommend rapid door-to-electrocardiography (ECG times for patients with ST-segment elevation myocardial infarction (STEMI. Previous quality improvement research at our institution revealed that we were not meeting this benchmark for walk-in STEMI patients. The objective is to investigate whether simple, directed changes in the emergency department (ED triage process for potential cardiac patients could decrease door-to-ECG times and secondarily door-to-balloon times. Methods: We conducted an interventional study at a large, urban, public teaching hospital from April 2010 to June 2012. All patients who walked into the ED with a confirmed STEMI were enrolled in the study. The primary intervention involved creating a chief complaint-based “cardiac triage” designation that streamlined the evaluation of potential cardiac patients. A secondary intervention involved moving our ECG technician and ECG station to our initial triage area. The primary outcome measure was door-to-ECG time and the secondary outcome measure was door-to-balloon time. Results: We enrolled 91 walk-in STEMI patients prior to the intervention period and 141 patients after the invention. We observed statistically significant reductions in door-to-ECG time (43±93 to 30±72 minutes, median 23 to 14 minutes p<0.01, ECG-to-activation time (87±134 to 52±82 minutes, median 43 to 31 minutes p<0.01, and door-to-balloon time (134±146 to 84±40 minutes, median 85 -75 minutes p=0.03. Conclusion: By creating a chief complaint-based cardiac triage protocol and by streamlining ECG completion, walk-in STEMI patients are systematically processed through the ED. This is not only associated with a decrease in door-to-balloon time, but also a decrease in the variability of the time sensitive intervals of door-to-ECG and ECG-to-balloon time. [West J Emerg Med. 2015;16(1:184–189.

  17. Asphalt and Wood Shingling. Roofing Workbook and Tests.

    Science.gov (United States)

    Brown, Arthur

    This combination workbook and set of tests contains materials on asphalt and wood shingling that have been designed to be used by those studying to enter the roofing and waterproofing trade. It consists of seven instructional units and seven accompanying objective tests. Covered in the individual units are the following topics: shingling…

  18. 40 CFR 65.44 - External floating roof (EFR).

    Science.gov (United States)

    2010-07-01

    ... Section 65.44 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) CONSOLIDATED FEDERAL AIR RULE Storage Vessels § 65.44 External floating roof (EFR). (a) EFR design requirements. The owner or operator who elects to control storage vessel regulated material...

  19. Wind loads on solar energy systems, mounted on flat roofs

    NARCIS (Netherlands)

    Geurts, C.P.W.; Bentum, C.A. van; Blackmore, P.

    2005-01-01

    Wind loads on solar energy systems are not covered by current wind loading standards. This paper describes results of a parametric study into the wind loads on solar energy systems, which are placed on flat roofs. Wind tunnel measurements have been carried out on a number of configurations. The resu

  20. Collapse of the roof of a football stadium

    NARCIS (Netherlands)

    Borsje, H.; Renier, B.; Burggraaf, H.G.

    2014-01-01

    In the summer of 2011 the Dutch football club FC Twente was building an extension of their stadium De Grolsch Veste, to increase the capacity of the stadium. On july 7th 2011, during construction, the roof of the partially finished extension collapsed. As a result of this accident two workers were

  1. THERMAL INFRARED INSPECTION OF ROOF INSULATION USING UNMANNED AERIAL VEHICLES

    Directory of Open Access Journals (Sweden)

    J. Zhang

    2015-08-01

    Full Text Available UAVs equipped with high-resolution thermal cameras provide an excellent investigative tool used for a multitude of building-specific applications, including roof insulation inspection. We have presented in this study a relative thermographic calibration algorithm and a superpixel Markov Random Field model to address problems in thermal infrared inspection of roof insulation using UAVs. The relative thermographic radiometric calibration algorithm is designed to address the autogain problem of the thermal camera. Results show the algorithm can enhance the contrast between warm and cool areas on the roof surface in thermal images, and produces more constant thermal signatures of different roof insulations or surfaces, which could facilitate both visual interpretation and computer-based thermal anomaly detection. An automatic thermal anomaly detection algorithm based on superpixel Markov Random Field is proposed, which is more computationally efficient than pixel based MRF, and can potentially improve the production throughput capacity and increase the detection accuracy for thermal anomaly detection. Experimental results show the effectiveness of the proposed method.

  2. Evaluation of green roof characteristics in green building assessment

    Directory of Open Access Journals (Sweden)

    Sekulić Mirjana

    2013-01-01

    Full Text Available Methodology of building evaluation based on green building characteristics is rapidly gaining momentum, mainly in foreign, but also in domestic building practice. This methodology is being carried out through different Green Building Certification Systems, which are complex evaluation mechanisms based on numerous criteria of sustainability, addressing both ecological issues, but also economic and social ones. Green roof represents one of the 'must have' features of contemporary buildings aiming to gain green label. This paradigm is based on their numerous characteristics which contribute to different aspects of building sustainability, among which are savings in energy and water consumption, but also ecological balance and quality of built environment. Criteria used for evaluation of green roof solutions and their overall contribution to the building, are integral part of all of the mentioned certification systems, but the way they are structured and formulated inside each system varies significantly, hence causing differences in evaluation results. This paper presents the analysis of green roof related criteria of three characteristic green building certification systems: LEED, BREEAM and CASBEE. These systems are chosen primarily because of the different evaluation methodology, but also because of their market prevalence and perspectives of usage in the domestic practice. Conclusions driven from these analyses and comparisons provide insight into main aspect of green roof planning and construction which are relevant for the overall building sustainability assessment.

  3. Demonstration of Three Corrosion-Resistant Sustainable Roofing Systems

    Science.gov (United States)

    2013-06-01

    panel using grommet-type metal fasteners with neoprene sleeves. Next, the crew installed the gutter piece over the eave flashing. The roof panels were...in Figure 33). The attachment was made using the fas- teners having the neoprene sleeves placed at every-other high rib. Figure 32. View showing

  4. 30 CFR 75.206 - Conventional roof support.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Conventional roof support. 75.206 Section 75.206 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND... square inches. (d) Materials other than wood used for support shall have support strength at...

  5. Green Roof Research through EPA's Regional Applied Research Effort - slides

    Science.gov (United States)

    The U.S. Environmental Protection Agency’s (EPA) Regional Applied Research Effort (RARE) allows the Regions of the EPA to choose research projects to be performed in partnership with EPA’s Office of Research and Development (ORD). Over the last decade, several green roof projects...

  6. Wind loads on solar energy systems, mounted on flat roofs

    NARCIS (Netherlands)

    Geurts, C.P.W.; Bentum, C.A. van; Blackmore, P.

    2005-01-01

    Wind loads on solar energy systems are not covered by current wind loading standards. This paper describes results of a parametric study into the wind loads on solar energy systems, which are placed on flat roofs. Wind tunnel measurements have been carried out on a number of configurations. The resu

  7. Urban reconciliation ecology: the potential of living roofs and walls.

    Science.gov (United States)

    Francis, Robert A; Lorimer, Jamie

    2011-06-01

    Reconciling human and non-human use of urban regions to support biological conservation represents a major challenge for the 21st century. The concept of reconciliation ecology, by which the anthropogenic environment may be modified to encourage non-human use and biodiversity preservation without compromising societal utilization, potentially represents an appropriate paradigm for urban conservation given the generally poor opportunities that exist for reserve establishment and ecological restoration in urban areas. Two habitat improvement techniques with great potential for reconciliation ecology in urban areas are the installation of living roofs and walls, which have been shown to support a range of taxa at local scales. This paper evaluates the reconciliation potential of living roofs and walls, in particular highlighting both ecological and societal limitations that need to be overcome for application at the landscape scale. We further consider that successful utilization of living roofs and walls for urban reconciliation ecology will rely heavily on the participation of urban citizens, and that a 'citizen science' model is needed to facilitate public participation and support and to create an evidence base to determine their effectiveness. Living roofs and walls are just one aspect of urban reconciliation ecology, but are particularly important 'bottom-up' techniques for improving urban biodiversity that can be performed directly by the citizenry.

  8. Collapse of the roof of a football stadium

    NARCIS (Netherlands)

    Borsje, H.; Renier, B.; Burggraaf, H.G.

    2014-01-01

    In the summer of 2011 the Dutch football club FC Twente was building an extension of their stadium De Grolsch Veste, to increase the capacity of the stadium. On july 7th 2011, during construction, the roof of the partially finished extension collapsed. As a result of this accident two workers were k

  9. Predictive Service Life Tests for Roofing Membranes: Phase 1

    Science.gov (United States)

    1993-12-01

    April 1991), pp 37-38, 40, 42, 44, 46. Puterman . M., K.H. Reinhorn, and M. Marton, "Specifications for Quality Assurance of Single-Ply Membrane...Material." Third International Symposium on Roofing Technology (NRCA, 1991), pp 271-275. Puterman , M., I. Soroka, and A. Bentur, "Deterioration of

  10. Survey of the Pagoda Timber Roof in Derneburg Castle

    Science.gov (United States)

    Perria, E.; Sieder, M.; Hoyer, S.; Krafczyk, C.

    2017-05-01

    The work analyses the historical roof of Derneburg Castle, in the municipality of Holle, Hildesheim's district, Lower Saxony, Germany. The roof is assembled according to Laves Balken's system (Laves beam's system), developed by the architect Georg Ludwig Friedrich Laves (1788-1864). The system has the peculiarity to consist of beams that are split along the half of the cross section, and maintained diverged by wooden wedges, distributed along the length of the beam. The system increases the height of the beam, and elevates the bending capacity of it (Weber, 1964). The work has been developed in the frame of an interdisciplinary project in the fields of architecture, engineering and photogrammetry. Main aim of the project is the developing of a structural model to understand the load-carrying capacity of Laves Balken's system from the laser-scanning model. For this reason, extensive surveys and photo documentation were collected on three areas of the roof construction, characterized by three peculiar usage of Laves Balken's system. The work presents the survey of the pagoda-roof that covers the tower of the castle, and problems that can be encountered during the survey of very complex timber constructions.

  11. Confounding adjustment through front-door blocking in longitudinal studies

    Directory of Open Access Journals (Sweden)

    Arvid Sjölander

    2013-03-01

    Full Text Available A common aim of epidemiological research is to estimate the causal effect of a particular exposure on a particular outcome. Towards this end, observed associations are often ‘adjusted’ for potential confounding variables. When the potential confounders are unmeasured, explicit adjustment becomes unfeasible. It has been demonstrated that causal effects can be estimated even in the presence of umeasured confounding, utilizing a method called ‘front-door blocking’. In this paper we generalize this method to longitudinal studies. We demonstrate that the method of front-door blocking poses a number of challenging statistical problems, analogous to the famous problems associ- ated with the method of ‘back-door blocking’.

  12. Simulation Optimization of the Crossdock Door Assignment Problem

    CERN Document Server

    Aickelin, Uwe

    2008-01-01

    The purpose of this report is to present the Crossdock Door Assignment Problem, which involves assigning destinations to outbound dock doors of Crossdock centres such that travel distance by material handling equipment is minimized. We propose a two fold solution; simulation and optimization of the simulation model simulation optimization. The novel aspect of our solution approach is that we intend to use simulation to derive a more realistic objective function and use Memetic algorithms to find an optimal solution. The main advantage of using Memetic algorithms is that it combines a local search with Genetic Algorithms. The Crossdock Door Assignment Problem is a new domain application to Memetic Algorithms and it is yet unknown how it will perform.

  13. The doors have been removed… for YOUR safety

    DEFF Research Database (Denmark)

    Abildgaard, Mette Simonsen

    A sociomaterial case study of how bombs (and their users), doors and politics instigated the destabilization and dismantling of the public telephone booth in Denmark, and the subsequent re-assembling process, through design contests and political struggle, to establish a new appropriate design...... Paper Long Abstract: This sociomaterial case study deals with the destabilization and dismantling of the public telephone booth in Denmark, which began in 1977-1978 when an unforeseen use - a series of bomb attacks - struck the booths in Copenhagen. As a safety measure, police removed the doors...... on the classic box-shaped telephone booths, which had been a part of Danish communication infrastructure since 1932. But the doors were never reinstalled after the capture of the user, who became known as The Telephone Bomber, and a competition for a new open design was commissioned in 1980. The winning design...

  14. Urban heat mitigation by roof surface materials during the East Asian summer monsoon

    Science.gov (United States)

    Lee, Seungjoon; Ryu, Youngryel; Jiang, Chongya

    2015-12-01

    Roof surface materials, such as green and white roofs, have attracted attention in their role in urban heat mitigation, and various studies have assessed the cooling performance of roof surface materials during hot and sunny summer seasons. However, summers in the East Asian monsoon climate region are characterized by significant fluctuations in weather events, such as dry periods, heatwaves, and rainy and cloudy days. This study investigated the efficacy of different roof surface materials for heat mitigation, considering the temperatures both at and beneath the surface of the roof covering materials during a summer monsoon in Seoul, Korea. We performed continuous observations of temperature at and beneath the surface of the roof covering materials, and manual observation of albedo and the normalized difference vegetation index for a white roof, two green roofs (grass (Poa pratensis) and sedum (Sedum sarmentosum)), and a reference surface. Overall, the surface temperature of the white roof was significantly lower than that of the grass and sedum roofs (1.1 °C and 1.3 °C), whereas the temperature beneath the surface of the white roof did not differ significantly from that of the grass and sedum roofs during the summer. The degree of cloudiness significantly modified the surface temperature of the white roof compared with that of the grass and sedum roofs, which depended on plant metabolisms. It was difficult for the grass to maintain its cooling ability without adequate watering management. After considering the cooling performance and maintenance efforts for different environmental conditions, we concluded that white roof performed better in urban heat mitigation than grass and sedum during the East Asian summer monsoon. Our findings will be useful in urban heat mitigation in the region.

  15. A Case Study of Effective Support Working Resistance and Roof Support Technology in Thick Seam Fully-Mechanized Face Mining with Hard Roof Conditions

    Directory of Open Access Journals (Sweden)

    Wei-bin Guo

    2017-06-01

    Full Text Available This paper presents the engineering geological properties and roof control tecnology for a thick coal seam fully-mechanized face mining with hard roof conditions (THC at the Jinhuagong Coal Mine (JCM, northwest China. The effective support working resistance and appropriate roof control technology are two critical factors for safe and productive mining in the THC. The load-estimate-method (LOEM is the effective method to determine the support working resistance for normal working conditions (the mining height less than 3.5 m. In order to prevent support crushing accidents from happening and to ensure the safety and high-efficiency in the THC, the LOEM was modified based on the structure of the overlying strata in the THC. The strata which can form the voussoir beam structure in normal working conditions and will break in the form of cantilever beam in the THC is defined as the key strata in the immediate roof. Therefore, the hanging length of the key strata in the immediate roof was considered in the LOEM. Furthermore, a method for calculating the hanging length of the key strata in the immediate roof and its influencing factors were proposed using cantilever beam theory analysis of the structure of the overlying strata. Moreover, in order to fully fill the goaf area with caving roof to reduce the energy accumulation of main roof movement, it was decided to apply destress blasting technique (DEBT at the JCM to control the large hanging length of the hard roof, so as to reduce the impact of the hard main roof movement on the working face. The key technique parameters of the roof caving borehole were also proposed. The obtained results demonstrated that the theoretical analysis is reasonable, and the chosen support type and the DEBT could meet the roof control requirements. The THC has achieved safety and high-efficiency mining.

  16. Roof Weakening of Hydraulic Fracturing for Control of Hanging Roof in the Face End of High Gassy Coal Longwall Mining: A Case Study

    Science.gov (United States)

    Huang, Bingxiang; Wang, Youzhuang

    2016-09-01

    The occurence of hanging roof commonly arises in the face end of longwall coal mining under hard roof conditions. The sudden break and subsequent caving of a hanging roof could result in the extrusion of gas in the gob to the face, causing gas concentrations to rise sharply and to increase to over a safety-limited value. A series of linear fracturing-holes of 32 mm diameter were drilled into the roof of the entries with an anchor rig. According to the theory that the gob should be fully filled with the fragmentized falling roof rock, the drilling depth is determined as being 3 5 times the mining height if the broken expansion coefficient takes an empirical value. Considering the general extension range of cracks and the supporting form of the entryway, the spacing distance between two drilling holes is determined as being 1 2 times the crack's range of extension. Using a mounting pipe, a high pressure resistant sealing device of a small diameter-size was sent to the designated location for the high-pressure hydraulic fracturing of the roof rock. The hydraulic fracturing created the main hydro-fracturing crack and airfoil branch cracks in the interior of the roof-rock, transforming the roof structure and weakening the strength of the roof to form a weak plane which accelerated roof caving, and eventually induced the full caving in of the roof in time with the help of ground pressure. For holes deeper than 4 m, retreating hydraulic fracturing could ensure the uniformity of crack extension. Tested and applied at several mines in Shengdong Mining District, the highest ruptured water pressure was found to be 55 MPa, and the hanging roof at the face end was reduced in length from 12 m to less than 1 2 m. This technology has eliminated the risk of the extrusion of gas which has accumulated in the gob.

  17. The doors have been removed… for YOUR safety

    DEFF Research Database (Denmark)

    Abildgaard, Mette Simonsen

    A sociomaterial case study of how bombs (and their users), doors and politics instigated the destabilization and dismantling of the public telephone booth in Denmark, and the subsequent re-assembling process, through design contests and political struggle, to establish a new appropriate design...... Paper Long Abstract: This sociomaterial case study deals with the destabilization and dismantling of the public telephone booth in Denmark, which began in 1977-1978 when an unforeseen use - a series of bomb attacks - struck the booths in Copenhagen. As a safety measure, police removed the doors...

  18. Using ground penetrating radar for roof hazard detection in underground mines

    Energy Technology Data Exchange (ETDEWEB)

    Molinda, G.M.; Monaghan, W.P.; Mowrey, G.L. [Dept. of Energy, Pittsburgh, PA (United States)

    1996-12-31

    Ground Penetrating Radar (GPR) is being investigated for the potential to determine roof hazards in underground mines. GPR surveys were conducted at four field sites with accompanying ground truth in order to determine the value of GPR for roof hazard detection. The resolution of the current system allows detection of gross roof fractures (>{1/4} in zone) or rider beds in coal measure roof. Data quality is not yet sufficient to detect small bed separations or subtle lithologic changes in the roof. Differences in data quality are discussed, as well as suggestions for collecting improved data.

  19. Using ground penetrating radar for roof hazard detection in underground mines

    Energy Technology Data Exchange (ETDEWEB)

    Molinda, G.M.; Monaghan, W.P.; Mowrey, G.L.; Persetic, G.F. [Department of Energy, Pittsburgh, PA (United States)

    1996-12-01

    Ground Penetrating Radar (GPR) is being investigated for the potential to determine roof hazards in underground mines. GPR surveys were conducted at four field sites with accompanying ground truth in order to determine the value of GPR for roof hazard detection. The resolution of the current system allows detection of gross roof fractures (>63 cm (>1/4 in) zone) or rider beds in coal measure roof. Data quality is not yet sufficient to detect small bed separations or subtle lithologic changes in the roof. Differences in data quality are discussed, as well as suggestions for collecting improved data.

  20. Conceptual Design and Feasibility Analyses of a Robotic System for Automated Exterior Wall Painting

    Directory of Open Access Journals (Sweden)

    Young S. Kim

    2008-11-01

    Full Text Available There are approximately 6,677,000 apartment housing units in South Korea. Exterior wall painting for such multi-dwelling apartment housings in South Korea represents a typical area to which construction automation technology can be applied for improvement in safety, productivity, quality, and cost over the conventional method. The conventional exterior wall painting is costly and labor-intensive, and it especially exposes workers to significant health and safety risks. The primary objective of this study is to design a conceptual model of an exterior wall painting robot which is applicable to apartment housing construction and maintenance, and to conduct its technical?economical feasibility analyses. In this study, a design concept using a high ladder truck is proposed as the best alternative for automation of the exterior wall painting. Conclusions made in this study show that the proposed exterior wall painting robot is technically and economically feasible, and can greatly enhance safety, productivity, and quality compared to the conventional method. Finally, it is expected that the conceptual model of the exterior wall painting robot would be efficiently used in various applications in exterior wall finishing and maintenance of other architectural and civil structures such as commercial buildings, towers, and high-rise storage tanks.

  1. Assessment of green roof systems in terms of water and energy balance

    Directory of Open Access Journals (Sweden)

    Mert Ekşi

    2016-01-01

    Full Text Available Green roofs concept term is used for extensive green roofs which are planted with herbaceous plants that can be adapted into changeable environmental conditions on a shallow substrate layer, require minimal maintenance, installed for their benefits to building and urban scale. Main objective of this study is to determine the characteristics of a green roof such as thermal insulation, water holding capacity, runoff characteristics, plant growth and its interaction with environmental factors in Istanbul climate conditions by performing comparative measurements. In this study, a research site (IU Green Roof Research Station was founded to assess water and energy balance of green roofs. Thus, a typical green roof was evaluated in terms of water and energy balance and its interaction with the building and city was determined. energy efficiency of green roof system was 77% higher than reference roof. Temperature fluctuations on green roof section of the roof were 79% lower. In addition, green roof retained 12,8% - 100% of precipitation and delayed runoff up to 23 hours depending on water content of substrate.

  2. Theoretical relationships between first flush of roof runoff and influencing factors

    Institute of Scientific and Technical Information of China (English)

    Biao WANG; Tian LI

    2009-01-01

    Considering the short length of building roofs,a theoretical analysis of the first flush of roof runoff was conducted based on the kinematic wave and pollutant erosion equations.This mathematical derivation with analytical solutions predicts pollutant mass first flush(MFF),mean concentration of initial runoff(MCIF),mean concentration of roof runoff(MCRRl with diversion of initial portion and residual mass available on the bed surface (RS) after the entire rnnoff under the condition of constant excess rainfall.And the effects of the associated influencing factors(roof length,roof gradient,roof surface roughness.rainfall intensity,rainfall duration,and erosion coefficients)on them were discussed while the values of parameters referred to the previous studies.The results showed that for roofs whose length is shorter than 20 m.both the increase in roof length and roof gradient and the decrease in roof surface roughness result in larger MFF and MCIF and smaller MCRR and RS.which is beneficial to water reuse and pollution reduction.The theoretical relationship between the first flush and the influencing factors may aid the planning and design of roof in terms of rainwater utilization or diffuse pollution control.

  3. Experimental Heat Transfer Study on Green Roofs in a Semiarid Climate during Summer

    Directory of Open Access Journals (Sweden)

    Roy J. Issa

    2015-01-01

    Full Text Available An experimental study was conducted on green roofs under the semiarid summer climatic conditions of West Texas to investigate the effect of soil type, moisture content, and the presence of a top soil grass layer on the conductive heat transfer through the roof. Two soil types were investigated: uniform sand and local silt clay. Tests were also conducted on a control roof. A dual-needle heat-pulse sensor was used to conduct thermal property tests on the soils. The tests reveal that unlike sand, the thermal conductivity of silt clay did not increase continuously with soil moisture. Better heat transfer conditions were achieved when the sand and silt clay roofs were watered to a water depth of 10 mm per day rather than double the amount of 20 mm per day. The roof with silt clay soil had the lowest fluctuation in inner temperature between daytime and nighttime. Green roofs with silt clay soil required more than twice the amount of soil moisture than green roofs with sand to achieve similar roof heat transfer rates. The best net heat flux gains for vegetated green roofs were 4.7 W/m2 for the sand roof and 7.8 W/m2 for the silt clay roof.

  4. Characteristics of Residual Atrial Posterior Wall and Roof-Dependent Atrial Tachycardias after Pulmonary Vein Isolation.

    Science.gov (United States)

    Matsumoto, Akinori; Fukuzawa, Koji; Kiuchi, Kunihiko; Konishi, Hiroki; Ichibori, Hirotoshi; Imada, Hiroshi; Hyogo, Kiyohiro; Kurose, Jun; Takaya, Tomofumi; Mori, Shumpei; Yoshida, Akihiro; Hirata, Ken-Ichi; Nishii, Tatsuya; Kono, Atsushi

    2016-10-01

    Roof-dependent atrial tachycardia (roof AT) sometimes occurs after pulmonary vein isolation (PVI) of atrial fibrillation (AF). This study aimed to investigate the relationship between the anatomy of the residual left atrial posterior wall and occurrence of roof AT. A total of 265 patients with AF who underwent PVI were enrolled. After the PVI, induced or recurrent roof AT was confirmed by an entrainment maneuver or activation mapping using a three-dimensional (3D) mapping system. To identify the predictors of roof AT, the minimum distance between both PVI lines (d-PVI) was measured by a 3D mapping system and the anatomical parameters, including the left atrial (LA) diameter, left atrial volume index (LAVi), and shape of the left atrial roof, were analyzed by 3D computed tomography. Roof AT was documented in 11 (4.2%) of 265 patients. A multivariable analysis demonstrated that the d-PVI, Deep V shape of the LA roof, and LAVi were associated with roof AT occurrences (d-PVI: odds ratio: 0.72, confidence interval [CI]: 0.61-0.86, P PVI and LAVi, respectively. The shorter d-PVI at the LA roof, greater LAVi, and Deep V shape were associated with the occurrence of a roof AT. © 2016 Wiley Periodicals, Inc.

  5. Field Testing of an Unvented Roof with Fibrous Insulation, Tiles, and Vapor Diffusion Venting

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K. [Building Science Corporation, Westford, MA (United States); Lstiburek, J. W. [Building Science Corporation, Westford, MA (United States)

    2016-02-01

    This research is a test implementation of an unvented tile roof assembly in a hot-humid climate (Orlando, FL; Zone 2A), insulated with air permeable insulation (netted and blown fiberglass). Given the localized moisture accumulation and failures seen in previous unvented roof field work, it was theorized that a 'diffusion vent' (water vapor open, but air barrier 'closed') at the highest points in the roof assembly might allow for the wintertime release of moisture, to safe levels. The 'diffusion vent' is an open slot at the ridge and hips, covered with a water-resistant but vapor open (500+ perm) air barrier membrane. As a control comparison, one portion of the roof was constructed as a typical unvented roof (self-adhered membrane at ridge). The data collected to date indicate that the diffusion vent roof shows greater moisture safety than the conventional, unvented roof design.

  6. A Review of Methods for the Manufacture of Residential Roofing Materials

    Energy Technology Data Exchange (ETDEWEB)

    Akbari, Hashem; Levinson, Ronnen; Berdahl, Paul

    2003-06-01

    Shingles, tiles, and metal products comprise over 80% (by roof area) of the California roofing market (54-58% fiberglass shingle, 8-10% concrete tile, 8-10% clay tile, 7% metal, 3% wood shake, and 3% slate). In climates with significant demand for cooling energy, increasing roof solar reflectance reduces energy consumption in mechanically cooled buildings, and improves occupant comfort in non-conditioned buildings. This report examines methods for manufacturing fiberglass shingles, concrete tiles, clay tiles, and metal roofing. The report also discusses innovative methods for increasing the solar reflectance of these roofing materials. We have focused on these four roofing products because they are typically colored with pigmented coatings or additives. A better understanding of the current practices for manufacturing colored roofing materials would allow us to develop cool colored materials creatively and more effectively.

  7. Measure Guideline: Incorporating Thick Layers of Exterior Rigid Insulation on Walls

    Energy Technology Data Exchange (ETDEWEB)

    Lstiburek, Joseph [Building Science Corporation, Westford, MA (United States); Baker, Peter [Building Science Corporation, Westford, MA (United States)

    2015-04-01

    This measure guideline provides information about the design and construction of wall assemblies that use layers of rigid exterior insulation thicker than 1-½ inches and that require a secondary cladding attachment location exterior to the insulation. The guideline is separated into several distinct sections that cover: fundamental building science principles relating to the use of exterior insulation on wall assemblies; design principles for tailoring this use to the specific project goals and requirements; and construction detailing to increase understanding about implementing the various design elements.

  8. Measure Guideline. Incorporating Thick Layers of Exterior Rigid Insulation on Walls

    Energy Technology Data Exchange (ETDEWEB)

    Lstiburek, Joseph [Building Science Corporation, Westford, MA (United States); Baker, Peter [Building Science Corporation, Westford, MA (United States)

    2015-04-09

    This measure guideline, written by the U.S. Department of Energy’s Building America team Building Science Corporation, provides information about the design and construction of wall assemblies that use layers of rigid exterior insulation thicker than 1-½ in. and that require a secondary cladding attachment location exterior to the insulation. The guideline is separated into several distinct sections that cover: (1) fundamental building science principles relating to the use of exterior insulation on wall assemblies; (2) design principles for tailoring this use to the specific project goals and requirements; and (3) construction detailing to increase understanding about implementing the various design elements.

  9. The role of exterior Weyl fluids on compact stellar structures in Randall-Sundrum gravity

    CERN Document Server

    Ovalle, J; Pasqua, A; Sotomayor, A

    2013-01-01

    In the context of the Randall-Sundrum braneworld, the minimal geometric deformation approach (MGD) is used to generate a new physically acceptable interior solution to Einstein's field equations for a spherically symmetric compact distribution. This new solution is used to elucidate the role of exterior Weyl stresses from bulk gravitons on compact stellar distributions. We found strong evidences showing that the exterior dark radiation ${\\cal U}^+$ always increases both the pressure and the compactness of stellar structures, and that the exterior "dark pressure" ${\\cal P}^+$ always reduces them.

  10. The role of exterior Weyl fluids on compact stellar structures in Randall-Sundrum gravity

    Science.gov (United States)

    Ovalle, J.; Linares, F.; Pasqua, A.; Sotomayor, A.

    2013-09-01

    In the context of the Randall-Sundrum braneworld, the minimal geometric deformation approach is used to generate a new physically acceptable interior solution to Einstein’s field equations for a spherically symmetric compact distribution. This new solution is used to elucidate the role of exterior Weyl stresses from bulk gravitons on compact stellar distributions. We found strong evidences showing that the exterior dark radiation U^+ always increases both the pressure and the compactness of stellar structures, and that the exterior ‘dark pressure’ P^+ always reduces them.

  11. Experimental study on fire propagation over combustible exterior facades in Japan

    Directory of Open Access Journals (Sweden)

    Nishio Yuhei

    2013-11-01

    Full Text Available With regard to the fire protection for exterior walls of building, only the fire resistance has been considered, according to the current building law of Japan. In the previous studies of the authors, a new test method for evaluation of fire propagation along combustible cladding was proposed using primarily test specimens of façade walls with exterior thermal insulation without vent layers. In this paper, newly obtained test results are discussed on other specimens of combustible façades such as wood, sandwich panel, photovoltaic sheet mounted on composite panel, combustible coating material, and exterior thermal insulation with vent layer.

  12. Segmentation of Sloped Roofs from Airborne LiDAR Point Clouds Using Ridge-Based Hierarchical Decomposition

    Directory of Open Access Journals (Sweden)

    Hongchao Fan

    2014-04-01

    Full Text Available This paper presents a new approach for roof facet segmentation based on ridge detection and hierarchical decomposition along ridges. The proposed approach exploits the fact that every roof can be composed of a set of gabled roofs and single facets which are separated by the gabled roofs. In this work, firstly, building footprints stored in OpenStreetMap are used to extract 3D points on roofs. Then, roofs are segmented into roof facets. The algorithm starts with detecting roof ridges using RANSAC since they are parallel to the horizon and situated on the top of the roof. The roof ridges are utilized to indicate the location and direction of the gabled roof. Thus, points on the two roof facets along a roof ridge can be identified based on their connectivity and coplanarity. The results of the segmentation benefit the further process of roof reconstruction because many parameters, including the position, angle and size of the gabled roof can be calculated and used as priori knowledge for the model-driven approach, and topologies among the point segments are made known for the data-driven approach. The algorithm has been validated in the test sites of two towns next to Bavaria Forest national park. The experimental results show that building roofs can be segmented with both high correctness and completeness simultaneously.

  13. 49 CFR 571.118 - Standard No. 118; Power-operated window, partition, and roof panel systems.

    Science.gov (United States)

    2010-10-01

    ...-operated window, partition, and roof panel systems. S1. Purpose and scope. This standard specifies requirements for power operated window, partition, and roof panel systems to minimize the likelihood of death... Figure 2. Power operated roof panel systems mean moveable panels in the vehicle roof which close...

  14. Monitoring Interior and Exterior Wall Inspections within a Virtual Environment

    Directory of Open Access Journals (Sweden)

    A. Z. Sampaio

    2012-01-01

    Full Text Available This paper describes two prototype applications based on the Virtual Reality (VR technology for use in maintenance planning of buildings. In a building, the paint coating applied to interior walls and the different types of materials applied to façades convey their aesthetic character and also perform an important function of protection. This a construction component which is exposed to agents of deterioration related to its use, needing the regular evaluation of its state of repair. The applications support the performance of such periodic inspections and the monitoring of interior and exterior wall maintenance, using the VR technology. Used during an inspection visit, the applications allow users to consult a database of irregularities, normally associated with the coating, classified by the most probable causes and by the recommended repair methodologies. In addition, a chromatic scale related to the degree of deterioration of the coating, defined as a function of the time between the dates of the application of the paint and the scheduled repainting, can be attributed to each element of coating monitored. This use of the VR technology allows inspections and the evaluation of the degree of wear and tear of materials to be carried out in a highly direct and intuitive manner.

  15. Exterior Orientation Estimation of Oblique Aerial Imagery Using Vanishing Points

    Science.gov (United States)

    Verykokou, Styliani; Ioannidis, Charalabos

    2016-06-01

    In this paper, a methodology for the calculation of rough exterior orientation (EO) parameters of multiple large-scale overlapping oblique aerial images, in the case that GPS/INS information is not available (e.g., for old datasets), is presented. It consists of five main steps; (a) the determination of the overlapping image pairs and the single image in which four ground control points have to be measured; (b) the computation of the transformation parameters from every image to the coordinate reference system; (c) the rough estimation of the camera interior orientation parameters; (d) the estimation of the true horizon line and the nadir point of each image; (e) the calculation of the rough EO parameters of each image. A developed software suite implementing the proposed methodology is tested using a set of UAV multi-perspective oblique aerial images. Several tests are performed for the assessment of the errors and show that the estimated EO parameters can be used either as initial approximations for a bundle adjustment procedure or as rough georeferencing information for several applications, like 3D modelling, even by non-photogrammetrists, because of the minimal user intervention needed. Finally, comparisons with a commercial software are made, in terms of automation and correctness of the computed EO parameters.

  16. Soft Roof Failure Mechanism and Supporting Method for Gob-Side Entry Retaining

    Directory of Open Access Journals (Sweden)

    Hongyun Yang

    2015-10-01

    Full Text Available To study the soft roof failure mechanism and the supporting method for a gateway in a gently inclined coal seam with a dip angle of 16° kept for gob-side entry retaining, and through the methodology of field investigation and numerical and analytical modeling, this paper analyzed the stress evolution law of roof strata at the working face end and determined that the sharp horizontal stress unloading phenomenon along the coal wall side did not appear after the working face advanced. Conversely, the horizontal stress along the gob side instantly decreased and the tensile stress produced, and the vertical stress in the central part of the roof had a higher reduction magnitude as well. An in-depth study indicates that the soft roof of the working face end subsided and seriously separated due to the effect of the front abutment pressure and the roof hanging length above the gob line, as well as certain other factors, including the rapid unloading of the lateral stress, tension and shear on the lower roof rock layer and dynamic disturbance. Those influencing factors also led to rapid crack propagation on a large scale and serious fracturing in the soft roof of the working face end. However, in the gob stress stabilized zone, the soft roof in the gob-side entry retaining has a shearing failure along the filling wall inside affected by the overburden pressure, rock bulking pressure, and roof gravity. To maintain the roof integrity, decrease the roof deformation, and enable the control of the working face end soft roof and the stabilization of the gob-side entry retaining roof, this study suggests that the preferred bolt installation angle for the soft roof situation is 70° based on the rock bolt extrusion strengthening theory.

  17. The effect of roofing material on the quality of harvested rainwater.

    Science.gov (United States)

    Mendez, Carolina B; Klenzendorf, J Brandon; Afshar, Brigit R; Simmons, Mark T; Barrett, Michael E; Kinney, Kerry A; Kirisits, Mary Jo

    2011-02-01

    Due to decreases in the availability and quality of traditional water resources, harvested rainwater is increasingly used for potable and non-potable purposes. In this study, we examined the effect of conventional roofing materials (i.e., asphalt fiberglass shingle, Galvalume(®) metal, and concrete tile) and alternative roofing materials (i.e., cool and green) on the quality of harvested rainwater. Results from pilot-scale and full-scale roofs demonstrated that rainwater harvested from any of these roofing materials would require treatment if the consumer wanted to meet United States Environmental Protection Agency primary and secondary drinking water standards or non-potable water reuse guidelines; at a minimum, first-flush diversion, filtration, and disinfection are recommended. Metal roofs are commonly recommended for rainwater harvesting applications, and this study showed that rainwater harvested from metal roofs tends to have lower concentrations of fecal indicator bacteria as compared to other roofing materials. However, concrete tile and cool roofs produced harvested rainwater quality similar to that from the metal roofs, indicating that these roofing materials also are suitable for rainwater harvesting applications. Although the shingle and green roofs produced water quality comparable in many respects to that from the other roofing materials, their dissolved organic carbon concentrations were very high (approximately one order of magnitude higher than what is typical for a finished drinking water in the United States), which might lead to high concentrations of disinfection byproducts after chlorination. Furthermore the concentrations of some metals (e.g., arsenic) in rainwater harvested from the green roof suggest that the quality of commercial growing media should be carefully examined if the harvested rainwater is being considered for domestic use. Hence, roofing material is an important consideration when designing a rainwater catchment.

  18. Optimizing the building envelopes with green roofs : a discussion of architectural and energy performance requirements

    Energy Technology Data Exchange (ETDEWEB)

    Hagerman, J. [Columbia Univ., New York, NY (United States). Dept. of Civil Engineering]|[Rafael Vinoly Architects, New York, NY (United States); Hodge, D. [Rafael Vinoly Architects, New York, NY (United States)

    2006-07-01

    This paper provided recommendations for optimized green roof technologies inspired by an architect firm's involvement in designing a 255,000 square foot green roof on top of the Howard Hughes Medical Institute's Janelia Farm Research Campus in Virginia. During the course of the green roof construction and installation, the architects found that green roofs needed design flexibility to meet their conceptual design requirements. It was suggested that the use of a modular system might allow for easier inspection access as well as the ability for the planting material to be reconfigured. It was noted that green roof systems can sometimes conflict with water management strategies of the building envelope. Green roof component lists do not make reference to the layers of construction within the building envelope, as it is often assumed that they are irrelevant to green roof design. Modular products offer Architects flexibility in design and maintenance, and products can be incorporated into more sophisticated water management details, offering simplicity of design, ease of installation, and ease of roof membrane inspection. A thermal analysis of modular and monolithic roof assemblies was conducted which showed that the assemblies contributed very little to the overall thermal insulation envelope when the positive thermal benefits of the green roof failed. It was recommended that green roof installations should be designed to sit directly on top of the roof membranes to replace the building's insulation envelope. Foamglas was proposed as a material for building insulation and to prevent root penetration. An evaluation of the R-values of various green roof systems at failure was also provided to give guidance to Architects incorporating green roofs in building envelopes. 3 refs., 3 tabs., 8 figs.

  19. Energy Performance Impacts from Competing Low-slope Roofing Choices and Photovoltaic Technologies

    Science.gov (United States)

    Nagengast, Amy L.

    With such a vast quantity of space, commercial low-slope roofs offer significant potential for sustainable roofing technology deployment. Specifically, building energy performance can be improved by installing rooftop energy technologies such as photovoltaic (PV) panels, and/or including designs such as white or green roofs instead of traditional black. This research aims to inform and support roof decisions through quantified energy performance impacts across roof choices and photovoltaic technologies. The primary dataset for this research was measured over a 16 month period (May 24, 2011 to October 13, 2012) from a large field experiment in Pittsburgh, Pennsylvania on top of a commercial warehouse with white, black and green roof sections, each with portions covered by polycrystalline photovoltaic panels. Results from the Pittsburgh experiment were extended to three different cities (San Diego, CA; Huntsville, AL; and Phoenix, AZ) chosen to represent a wide range of irradiance and temperature values. First, this research evaluated the difference in electricity production from a green-moss roof and black roof underneath photovoltaic panels to determine if the green roof's cooler air increases the panel efficiency. Second, separate studies examine 1) average hourly heat flux by month for unobstructed and shaded roof membranes 2) heat flux peak time delay, and 3) air temperature across roof types. Results of this research show green roofs slightly increased (0.8-1.5%) PV panel efficiency in temperatures approximately at or above 25° C (77°F) compared to black roofs. However in cool climates, like Pittsburgh, the roof type under the PV panels had little overall impact on PV performance when considering year round temperatures. Instead, roof decisions should place a stronger emphasis on heat flux impacts. The green roof outperformed both black and white roofs at minimizing total conductive heat flux. These heat flow values were used to develop a new, straight

  20. Optimization of Circular Side Door Beam for Crashworthiness Analysis

    Directory of Open Access Journals (Sweden)

    Raja Sharmi Raja Husin

    2012-01-01

    Full Text Available Structural optimization related to crashworthiness and energy absorption capability is particularly importance to the automotive industry. The optimization involves highly nonlinear computational analysis and design with many material and structure parameters. This paper presents a crashworthiness design of the circular side door beam which attach to the side door structures. The response surface method (RSM is utilized to formulate the complex crashworthiness design problem in the case of optimization. In this study, side door beam will be optimized. The beams in circular shape were studied and compared. The focus is on finding an optimum cross-section shape of the beam in order to improve the energy absorption character.  An optimization problem is formulated to find the maximum energy absorbed with the maximum peak load as a constraint, the shape of the beam cross section and the thickness as variable. The structure optimum design and simulation analysis of automobile side-door beam was carried out by using Finite Element (FE method.

  1. Locked doors in acute inpatient psychiatry: a literature review.

    Science.gov (United States)

    van der Merwe, M; Bowers, L; Jones, J; Simpson, A; Haglund, K

    2009-04-01

    Many acute inpatient psychiatric wards in the UK are permanently locked, although this is contrary to the current Mental Health Act Code of Practice. To conduct a literature review of empirical articles concerning locked doors in acute psychiatric inpatient wards, an extensive literature search was performed in SAGE Journals Online, EBM Reviews, British Nursing Index, CINAHL, EMBASE Psychiatry, International Bibliography of the Social Sciences, Ovid MEDLINE, PsycINFO and Google, using the search terms 'open$', 'close$', '$lock$', 'door', 'ward', 'hospital', 'psychiatr', 'mental health', 'inpatient' and 'asylum'. A total of 11 empirical papers were included in the review. Both staff and patients reported advantages (e.g. preventing illegal substances from entering the ward and preventing patients from absconding and harming themselves or others) and disadvantages (e.g. making patients feel depressed, confined and creating extra work for staff) regarding locked doors. Locked wards were associated with increased patient aggression, poorer satisfaction with treatment and more severe symptoms. The limited literature available showed the urgent need for research to determine the real effects of locked doors in inpatient psychiatry.

  2. 77 FR 62446 - Every Door Direct Mail-Retail

    Science.gov (United States)

    2012-10-15

    ... increase their marketing efforts. On July 10, 2012, the Postal Service filed a request with the Postal... alternative marketing name of Every Door Direct Mail for commercial mailings of Standard Mail flats with... positioning on the host piece. d. The attachment does not interfere with processing or delivery. Folded...

  3. De Rijnvervuiling door het ongeval bij Sandoz Ag

    NARCIS (Netherlands)

    Canton JH; van Gestel CAM; Greve PA; de Jong AP; Knoop J; de Kruijf HAM; van de Meent D; van Noort PCM; de Nijs T; Struijs J; Zwart; D. de

    1986-01-01

    Op basis van de door DBW/RIZA en het RIVM uitgevoerde metingen van de concentraties in Rijnwater van de bij Bazel geloosde bestrijdingsmiddelen zijn schattingen gemaakt van de maximale concentraties van deze stoffen in de Nederlandse oppervlaktewateren. Het betrof met name de stoffen disulfoton en

  4. Ontwikkeling van licht reflecterende deklagen door KWS: KonweBright

    NARCIS (Netherlands)

    ter Huerne, Henderikus L.; Hetebrij, Dirk; Elfring, Jan

    2014-01-01

    In het kader van het milieu staan op dit moment asfalt verhardingsmaterialen met sterker lichtreflecterende eigenschappen in de belangstelling. Dergelijke materialen hebben als voordeel dat door de verbeterde reflectie-eigenschappen op de wegen minder openbare verlichting nodig is en toch een goede

  5. DOORS English--The Cognitive Basis of Rhetorical Models.

    Science.gov (United States)

    Taylor, Karl K.

    1979-01-01

    The Development of Operational Reasoning Skills (DOORS) program at Illinois Central College is an interdisciplinary experiment that guides students from concrete to formal operational levels of thought to ensure that they understand the concepts and cognitive skills undergirding the rhetorical modes. (RL)

  6. Melkweg haarscherp in kaart door stabiele meetsystemen TNO

    NARCIS (Netherlands)

    Gielesen, W.L.M.

    2014-01-01

    Sinds enkele maanden draait de Ga¡a-satel]¡et van Esa op anderhalf miljoen kilometer van de aarde. Doel is om een zeer nauwkeurige driedimensionale kaart te maken van ongeveer een miljard sterren in ons Melkwegstetsel. Aan boord zijn twee meetsystemen, door TNO ontwikketd en gebouwd,

  7. Eerste kwartaal 2010 sierteelt: omzetgroei door herstel in maart

    NARCIS (Netherlands)

    Jukema, G.D.; Knijff, van der A.

    2010-01-01

    Het eerste kwartaal van 2010 begon door het winterse weer in januari slecht, maar eindigde hoopvol. Zowel in eigen land als op belangrijke exportmarkten remde winterse omstandigheden de aanvoer, verkoop en handel in bloemen en planten sterk. In februari en met name maart herstelde de aanvoer en mark

  8. A Scholar Who Knocks at the Door to Friendship

    Institute of Scientific and Technical Information of China (English)

    2004-01-01

    <正>Senegalese scholar Adama Gaye came from far away Africa to visit China in March when there was still a chill in the early spring air. He is not an ordinary scholar, but an African friend who has come to knock at the door to friendship.The government of Senegal established diplomatic relations

  9. Melkweg haarscherp in kaart door stabiele meetsystemen TNO

    NARCIS (Netherlands)

    Gielesen, W.L.M.

    2014-01-01

    Sinds enkele maanden draait de Ga¡a-satel]¡et van Esa op anderhalf miljoen kilometer van de aarde. Doel is om een zeer nauwkeurige driedimensionale kaart te maken van ongeveer een miljard sterren in ons Melkwegstetsel. Aan boord zijn twee meetsystemen, door TNO ontwikketd en gebouwd, verantwoordelij

  10. Schade aan gewassen door ozon in het groeiseizoen van 1994

    NARCIS (Netherlands)

    Tonneijck, A.E.G.; Dijk, van C.J.

    1995-01-01

    Op vier locaties is het effect van ozon op klaver (Trifolium subterraneum) en boon (Phaseolus vulgaris L.) onderzocht. Bij beide planten is substantiele bladbeschadiging door ozon op alle locaties waargenomen. Bij de teelt van gewassen moet rekening worden gehouden met de negatieve effecten van ozon

  11. Portal: Your Door to World Languages and Cultures

    Science.gov (United States)

    Elliott, Don; Lawton, Rachele

    2009-01-01

    Portal: Your Door to World Languages and Cultures was a series of public cultural events, in a variety of formats, created through a new partnership between the credit and continuing education (noncredit) foreign language programs at the Community College of Baltimore County (CCBC). Portal was designed to cultivate interest in foreign languages…

  12. ORIGINAL ARTICLES Door-to-needle time for administration of ...

    African Journals Online (AJOL)

    4 SAMJ. 241. Ischaemic heart disease (IHD) is a major cause of mortality and ... seen when the fibrinolytic is given within the first hour of symptom ... (AHA/ACC) guidelines recommend a door-to-needle time of .... The final number included in.

  13. Quantification of leakages and leakage pathways in wooden buildings. Part 2.: Manual for blower door measurements - advanced methods. Final report; Quantifizierung einzelner Leckagen und Leckagewege bei Gebaeuden in Holzbauart. T. 2: Handbuch zur Durchfuehrung von Blower Door-Messungen - Erweiterte Messmethoden. Abschlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Hall, M.; Geissler, A.; Hauser, G.

    2001-07-01

    The first part of the project investigated the limits of application of the Opening A Door, Adding A Hole, Guard Zone and Deduction methods in order to find out which of them is the most reliable in given circumstances. This involved comparative measurements in the roof section of a model building. The roof section was specially designed and constructed for this purpose. The second part of the investigations comprised in situ measurements using a prototype measuring system developed in an earlier project, which was further developed into a flexible system for quantification of random leakages also in corners and along edges. It can be used either as a double chamber or as a single chamber combined, e.g., with a blower door as compensating volume flow meter. The laboratory experiments were supplemented by field tests. [German] Fuer die Quantifizierung der Luftdichtheit einzelner Gebaeudebereiche werden im ersten Teil des Projektes zur Schaffung von soliden Grundlagen die bekannten Methoden Opening A Door, Adding A Hole, Guard Zone und Deduktion auf ihre Anwendungsgrenzen untersucht. Es wird erarbeitet, unter welchen Bedingungen mit welcher Methode die sichersten Ergebnisse erhalten werden. Hierfuer werden Vergleichsmessungen im Dachbereich eines Versuchsgebaeudes unter bekannten Randbedingungen durchgefuehrt. Um die Moeglichkeit zu haben, konkrete Randbedingungen einzustellen wurde das vorhandene Versuchshaus umgebaut bzw. erweitert. Ein neuer Dachaufbau wurde entsprechend den Anforderungen des Projektes konzipiert und errichtet. Die Leckagen von einzelnen Bauteilen sollen im zweiten Teil des Projektes mit Hilfe eines in situ-Messgeraetes quantifiziert werden. Ein Messsystem zur Bestimmung der Luftdichtheit von Bauteilen in situ wurde im Rahmen eines frueheren Forschungsvorhabens als Prototyp bereits entwickelt. Ausgehend von dem aelteren Prototypen wird in diesem Projekt ein flexibles Messsystem entwickelt, mit dem die Quantifizierung beliebiger einzelner Leckagen

  14. Green roof impact on the hydrological cycle components

    Science.gov (United States)

    Lamera, Carlotta; Rulli, Maria Cristina; Becciu, Gianfranco; Rosso, Renzo

    2013-04-01

    In the last decades the importance of storm water management in urban areas has increased considerably, due to both urbanization extension and to a greater concern for environment pollution. Traditional storm water control practices, based on the "all to the sewer" attitude, rely on conveyance to route storm water runoff from urban impervious surfaces towards the nearby natural water bodies. In recent years, infiltration facilities are receiving an increasing attention, due to their particular efficiency in restoring a balance in hydrological cycle quite equal to quite pre-urbanization condition. In particular, such techniques are designed to capture, temporarily retain and infiltrate storm water, promote evapotranspiration and harvest water at the source, encouraging in general evaporation, evapotranspiration, groundwater recharge and the re-use of storm water. Green roofs are emerging as an increasingly popular Sustainable Urban Drainage Systems (SUDS) technique for urban storm water management. Indeed, they are able to operate hydrologic control over storm water runoff: they allow a significant reduction of peak flows and runoff volumes collected by drainage system, with a consequent reduction of flooding events and pollution masses discharges by CSO. Furthermore green roofs have a positive influence on the microclimate in urban areas by helping in lower urban air temperatures and mitigate the heat island effect. Last but not least, they have the advantage of improving the thermal insulation of buildings, with significant energy savings. A detailed analysis of the hydrological dynamics, connected both with the characteristics of the climatic context and with the green roof technical design, is essential in order to obtain a full characterization of the hydrologic behavior of a green roof system and its effects on the urban water cycle components. The purpose of this paper is to analysis the hydrological effects and urban benefits of the vegetation cover of a

  15. La política exterior de Sudáfrica post Apartheid

    OpenAIRE

    2004-01-01

    El embajador de Sudáfrica en Argentina realiza aquí un seguimiento de cuestiones centrales en el diseño de la política exterior de su país en los últimos 10 años. Para ello aborda 4 ejes centrales: el significado del año 2004 para Sudáfrica; los fundamentos de su política exterior, la política de relaciones exteriores de Sudáfrica dentro del sistema mundial y la dirección de la política de relaciones exteriores durante la primera década de democracia en el país. Los posicionamientos, sus razo...

  16. CONTINUOUS DEPENDENCE ON VELOCITY FOR THE BACKWARD DYNAMO EQUATION ON AN EXTERIOR DOMAIN

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    In this paper we study solutions to a forward Dynamo equation depending continuously on the velocity on an exterior domain,using Logarithmic Convexity Methods.We obtain some more weaker conditions by introducing the unbounded domain.

  17. Brane-world stars with a solid crust and vacuum exterior

    Science.gov (United States)

    Ovalle, Jorge; Gergely, László Á.; Casadio, Roberto

    2015-02-01

    The minimal geometric deformation approach is employed to show the existence of brane-world stellar distributions with a vacuum Schwarzschild exterior, thus without energy leaking from the exterior of the brane-world star into the extra dimension. The interior satisfies all the elementary criteria of physical acceptability for a stellar solution, namely, it is regular at the origin, the pressure and density are positive and decrease monotonically with increasing radius, and all energy conditions are fulfilled. A very thin solid crust with negative radial pressure separates the interior from the exterior, having a thickness Δ inversely proportional to both the brane tension σ and the radius R of the star, i.e. {{Δ }-1}˜ Rσ . This brane-world star with Schwarzschild exterior would appear only thermally radiating to a distant observer and be fully compatible with the stringent constraints imposed on stellar parameters by observations of gravitational lensing, orbital evolutions or properties of accretion disks.

  18. Building America Top Innovations 2013 Profile – Exterior Rigid Insulation Best Practices

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2013-09-01

    In this Top Innovation profile, field and lab studies by BSC, PHI, and NorthernSTAR characterize the thermal, air, and vapor resistance properties of rigid foam insulation and describe best practices for their use on walls, roofs, and foundations.

  19. Door locking and exit security measures on acute psychiatric admission wards

    NARCIS (Netherlands)

    Nijman, H.L.I.; Bowers, L.; Haglund, K.; Muir-Cochrane, E.; Simpson, A.; Merwe, M. van der

    2011-01-01

    Locking the exit doors of psychiatric wards is believed to reduce the risk of patients absconding. The aims of the study were to investigate both the prevalence of door locking and other exit security measures on UK admission wards, as well as whether door locking appears to be effective in keeping

  20. 16 CFR 1211.13 - Inherent force activated secondary door sensors.

    Science.gov (United States)

    2010-01-01

    ... sensors. 1211.13 Section 1211.13 Commercial Practices CONSUMER PRODUCT SAFETY COMMISSION CONSUMER PRODUCT... § 1211.13 Inherent force activated secondary door sensors. (a) Normal operation test. (1) A force activated door sensor of a door system installed according to the installation instructions shall actuate...

  1. Elementos para una perspectiva crítica de la política exterior mexicana

    OpenAIRE

    Luis Miguel Valdivia Santa María

    2001-01-01

    Este trabajo nace de la inquietud por esclarecer la pregunta: ¿existe una teoría de la política exterior de México? ¿Cuáles son sus elementos constitutivos? ¿Qué capacidad explicativa y prospectiva, del fenómeno, tiene para servir de guía de acción y perfeccionamiento de la política exterior de México?

  2. Elementos para una perspectiva crítica de la política exterior mexicana

    Directory of Open Access Journals (Sweden)

    Luis Miguel Valdivia Santa María

    2001-01-01

    Full Text Available Este trabajo nace de la inquietud por esclarecer la pregunta: ¿existe una teoría de la política exterior de México? ¿Cuáles son sus elementos constitutivos? ¿Qué capacidad explicativa y prospectiva, del fenómeno, tiene para servir de guía de acción y perfeccionamiento de la política exterior de México?

  3. Environmental sustainability comparison of a hypothetical pneumatic waste collection system and a door-to-door system.

    Science.gov (United States)

    Punkkinen, Henna; Merta, Elina; Teerioja, Nea; Moliis, Katja; Kuvaja, Eveliina

    2012-10-01

    Waste collection is one of the life cycle phases that influence the environmental sustainability of waste management. Pneumatic waste collection systems represent a new way of arranging waste collection in densely populated urban areas. However, limited information is available on the environmental impacts of this system. In this study, we compare the environmental sustainability of conventional door-to-door waste collection with its hypothetical pneumatic alternative. Furthermore, we analyse whether the size of the hypothetical pneumatic system, or the number of waste fractions included, have an impact on the results. Environmental loads are calculated for a hypothetical pneumatic waste collection system modelled on an existing dense urban area in Helsinki, Finland, and the results are compared to those of the prevailing, container-based, door-to-door waste collection system. The evaluation method used is the life-cycle inventory (LCI). In this study, we report the atmospheric emissions of greenhouse gases (GHG), SO(2) and NO(x). The results indicate that replacing the prevailing system with stationary pneumatic waste collection in an existing urban infrastructure would increase total air emissions. Locally, in the waste collection area, emissions would nonetheless diminish, as collection traffic decreases. While the electricity consumption of the hypothetical pneumatic system and the origin of electricity have a significant bearing on the results, emissions due to manufacturing the system's components prove decisive. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. 基于外围护结构性能的住宅建筑能耗模拟分析%Simulation and Analysis on Residential Building Energy Consumption Based on Exterior Envelope Features

    Institute of Scientific and Technical Information of China (English)

    段良飞; 邵宗义; 张航

    2015-01-01

    Different exterior envelopes of residential building were considered by simulating building cooling and heating load with eQUEST. Various factors, including the heat transfer coefficient of external wall, heat transfer coefficient of external window, comprehensive window shading coefficient and roofing, were analyzed by comparing the simulation model with the original building, which can be referenced for similar architectural design and selection of exterior envelope.%采用 eQUEST 模拟软件对某住宅建筑不同外围护结构条件下的冷、热负荷情况进行模拟。通过与原建筑模拟结果对比,得出外墙传热系数、外窗传热系数、综合遮阳系数、屋面等因素对其能耗的影响,分析了每个因素对住宅建筑负荷影响的权重,供同类建筑设计、外围护结构选型时参考。

  5. Positive effects of vegetation: urban heat island and green roofs.

    Science.gov (United States)

    Susca, T; Gaffin, S R; Dell'osso, G R

    2011-01-01

    This paper attempts to evaluate the positive effects of vegetation with a multi-scale approach: an urban and a building scale. Monitoring the urban heat island in four areas of New York City, we have found an average of 2 °C difference of temperatures between the most and the least vegetated areas, ascribable to the substitution of vegetation with man-made building materials. At micro-scale, we have assessed the effect of surface albedo on climate through the use of a climatological model. Then, using the CO(2) equivalents as indicators of the impact on climate, we have compared the surface albedo, and the construction, replacement and use phase of a black, a white and a green roof. By our analyses, we found that both the white and the green roofs are less impactive than the black one; with the thermal resistance, the biological activity of plants and the surface albedo playing a crucial role.

  6. Towards a generic rainfall-runoff model for green roofs.

    Science.gov (United States)

    Kasmin, H; Stovin, V R; Hathway, E A

    2010-01-01

    A simple conceptual model for green roof hydrological processes is shown to reproduce monitored data, both during a storm event, and over a longer continuous simulation period. The model comprises a substrate moisture storage component and a transient storage component. Storage within the substrate represents the roof's overall stormwater retention capacity (or initial losses). Following a storm event the retention capacity is restored by evapotranspiration (ET). However, standard methods for quantifying ET do not exist. Monthly ET values are identified using four different approaches: analysis of storm event antecedent dry weather period and initial losses data; calibration of the ET parameter in a continuous simulation model; use of the Thornthwaite ET formula; and direct laboratory measurement of evaporation. There appears to be potential to adapt the Thornthwaite ET formula to provide monthly ET estimates from local temperature data. The development of a standardized laboratory test for ET will enable differences resulting from substrate characteristics to be quantified.

  7. Mechanical model of roof on stope and its analysis

    Institute of Scientific and Technical Information of China (English)

    WAGN Hong-wei; CHEN Zhong-hui; DU Ze-chao; ZHANG Jian

    2005-01-01

    Based on the engineering background of No.8402 stope face in Silaogou Coal Mine of Datong Mineral Bureau and the theory of plate presented by researchers before,considering surrounding rock structure in the stope and according to mechanical property of rock bodies with various kinds of joint planes, presented an assumption that the key roof was divided into a series of elastic plate group by joint planes, then set up mechanical model of elastic plate group with pin joint. After compared the deflection and the stress in the mechanical model by numerical modeling with data from field engineering, the rule of rock plates' break in turn and the difference in rock plates' stress during the roof's first and periodic weighting along the stope face were found.

  8. Stress fracture in acetabular roof due to motocross: case report

    Directory of Open Access Journals (Sweden)

    Alexandre de Paiva Luciano

    2016-06-01

    Full Text Available ABSTRACT One of the first steps to be taken in order to reduce sports injuries such as stress fractures is to have in-depth knowledge of the nature and extent of these pathological conditions. We present a case report of a stress fracture of the acetabular roof caused through motocross. This type of case is considered rare in the literature. The description of the clinical case is as follows. The patient was a 27-year-old male who started to have medical follow-up because of uncharacteristic pain in his left hip, which was concentrated mainly in the inguinal region of the left hip during motocross practice. After clinical investigation and complementary tests, he was diagnosed with a stress fracture of the acetabular roof.

  9. Stress fracture in acetabular roof due to motocross: case report.

    Science.gov (United States)

    de Paiva Luciano, Alexandre; Filho, Nelson Franco

    2016-01-01

    One of the first steps to be taken in order to reduce sports injuries such as stress fractures is to have in-depth knowledge of the nature and extent of these pathological conditions. We present a case report of a stress fracture of the acetabular roof caused through motocross. This type of case is considered rare in the literature. The description of the clinical case is as follows. The patient was a 27-year-old male who started to have medical follow-up because of uncharacteristic pain in his left hip, which was concentrated mainly in the inguinal region of the left hip during motocross practice. After clinical investigation and complementary tests, he was diagnosed with a stress fracture of the acetabular roof.

  10. Modeling Košice Green Roofs Maps

    Science.gov (United States)

    Poorova, Zuzana; Vranayova, Zuzana

    2017-06-01

    The need to house population in urban areas is expected to rise to 66% in 2050, according to United Nations. The replacement of natural permeable green areas with concrete constructions and hard surfaces will be noticed. The densification of existing built-up areas is responsible for the decreasing vegetation, which results in the lack of evapotranspiration cooling the air. Such decreasing vegetation causes urban heat islands. Since roofs and pavements have a very low albedo, they absorb a lot of sunlight. Several studies have shown that natural and permeable surfaces, as in the case of green roofs, can play crucial role in mitigating this negative climate phenomenon and providing higher efficiency for the building, leading to savings. Such as water saving, what is the main idea of this research.

  11. Identifying fall-protection training needs for residential roofing subcontractors.

    Science.gov (United States)

    Hung, Yu-Hsiu; Winchester, Woodrow W; Smith-Jackson, Tonya L; Kleiner, Brian M; Babski-Reeves, Kari L; Mills, Thomas H

    2013-05-01

    Falls remain the leading cause of injuries and fatalities in the small residential roofing industry and analogous investigations are underrepresented in the literature. To address this issue, fall-protection training needs were explored through 29 semi-structured interviews among residential roofing subcontractors with respect to recommendations for the design of fall-protection training. Content analysis using grounded theory was conducted to analyze participants' responses. Results of the analysis revealed six themes related to the design of current fall-protection training: (1) barriers to safety training; (2) problems of formal safety-training programs; (3) recommendations for training implementation; (4) important areas for fall-protection training; (5) training delivery means; and (6) design features of training materials. Results of the study suggest the need for informal jobsite safety training to complement what had been covered in formalized safety training. This work also provides recommendations for the design of a more likely adopted fall-protection training program.

  12. Free Vibration of Laminated Composite Hypar Shell Roofs with Cutouts

    Directory of Open Access Journals (Sweden)

    Sarmila Sahoo

    2011-01-01

    Full Text Available Use of laminated composites in civil engineering structural components including shell roofs is increasing day by day due to their light weight, high specific strength, and stiffness properties. In the present paper, laminated composite hypar shell (hyperbolic paraboloidal shells bounded by straight edges roofs with cutouts are analyzed for their free vibration characteristics using finite element method. An eight-noded curved shell element is used for modeling the shell. Specific numerical problems of earlier investigators are solved to compare their results with the present formulation. A number of problems are further solved where the size of the cutouts and their positions with respect to the shell centre are varied for different edge constraints. The results are furnished in the form of figures and tables. The results are examined thoroughly to arrive at some meaningful conclusions useful to designers.

  13. Modelling reduction of urban heat load in Vienna by modifying surface properties of roofs

    Science.gov (United States)

    Žuvela-Aloise, Maja; Andre, Konrad; Schwaiger, Hannes; Bird, David Neil; Gallaun, Heinz

    2017-01-01

    The study examines the potential of urban roofs to reduce the urban heat island (UHI) effect by changing their reflectivity and implementing vegetation (green roofs) using the example of the City of Vienna. The urban modelling simulations are performed based on high-resolution orography and land use data, climatological observations, surface albedo values from satellite imagery and registry of the green roof potential in Vienna. The modelling results show that a moderate increase in reflectivity of roofs (up to 0.45) reduces the mean summer temperatures in the densely built-up environment by approximately 0.25 °C. Applying high reflectivity materials (roof albedo up to 0.7) leads to average cooling in densely built-up area of approximately 0.5 °C. The green roofs yield a heat load reduction in similar order of magnitude as the high reflectivity materials. However, only 45 % of roof area in Vienna is suitable for greening and the green roof potential mostly applies to industrial areas in city outskirts and is therefore not sufficient for substantial reduction of the UHI effect, particularly in the city centre which has the highest heat load. The strongest cooling effect can be achieved by combining the green roofs with high reflectivity materials. In this case, using 50 or 100 % of the green roof potential and applying high reflectivity materials on the remaining surfaces have a similar cooling effect.

  14. Impact of green roofs on stormwater quality in a South Australian urban environment.

    Science.gov (United States)

    Razzaghmanesh, M; Beecham, S; Kazemi, F

    2014-02-01

    Green roofs are an increasingly important component of water sensitive urban design systems and can potentially improve the quality of urban runoff. However, there is evidence that they can occasionally act as a source rather than a sink for pollutants. In this study, the water quality of the outflow from both intensive and extensive green roof systems were studied in the city of Adelaide, South Australia over a period of nine months. The aim was to examine the effects of different green roof configurations on stormwater quality and to compare this with runoff from aluminium and asphalt roofs as control surfaces. The contaminant concentrations in runoff from both intensive and extensive green roofs generally decreased during the study period. A comparison between the two types of green roof showed that except for some events for EC, TDS and chloride, the values of the parameters such as pH, turbidity, nitrate, phosphate and potassium in intensive green roof outflows were higher than in the outflows from the extensive green roofs. These concentrations were compared to local, state, national and international water quality guidelines in order to investigate the potential for outflow runoff from green roofs to be reused for potable and non-potable purposes. The study found that green roof outflow can provide an alternative water source for non-potable purposes such as urban landscape irrigation and toilet flushing.

  15. Potted Plants on Flat Roof as a Strategy to Reduce Indoor Temperature in Malaysian Climate

    Directory of Open Access Journals (Sweden)

    Asmat Ismail

    2010-01-01

    Full Text Available Problem statement: The phenomenon of global warming or climate change has led to many environmental issues including higher atmospheric temperatures, intensive precipitation, increase greenhouse gaseous emission and of course increase indoor discomfort condition. Researchers worldwide collectively agreed that one way of reducing the impact of global warming is by implementing green roof technology which integrates vegetation, growing medium and water proofing membrane on top of the roof surface. However, none of them have ever studied on how much the potted plants on the roof top could contribute to lessen the environmental problems. Therefore, this study investigates the effect of potted plants on flat roof on the indoor temperature inside building in Malaysian climate. Approach: This study emphasized on experimental approach of the room with flat roof. Measurements were conducted in two phases i.e., room with potted plant on the roof and room with bare roof. The measurements were conducted on the same room. Results: The experiment showed a promising result whereby the average indoor temperature dropped between 0.21 and 1.73°C had been observed during the measurements, while average indoor surface temperatures difference between roof with potted plants and bare roof of 7.86°C had been recorded during daytime hour. Conclusion: Potted plants on flat roof had a great potential in reducing the indoor temperature of the room underneath and could contributed to the reduction of energy consumption in building.

  16. Cycle graph analysis for 3D roof structure modelling: Concepts and performance

    Science.gov (United States)

    Perera, Gamage Sanka Nirodha; Maas, Hans-Gerd

    2014-07-01

    The paper presents a cycle graph analysis approach to the automatic reconstruction of 3D roof models from airborne laser scanner data. The nature of convergences of topological relations of plane adjacencies, allowing for the reconstruction of roof corner geometries with preserved topology, can be derived from cycles in roof topology graphs. The topology between roof adjacencies is defined in terms of ridge-lines and step-edges. In the proposed method, the input point cloud is first segmented and roof topology is derived while extracting roof planes from identified non-terrain segments. Orientation and placement regularities are applied on weakly defined edges using a piecewise regularization approach prior to the reconstruction, which assists in preserving symmetries in building geometry. Roof corners are geometrically modelled using the shortest closed cycles and the outermost cycle derived from roof topology graph in which external target graphs are no longer required. Based on test results, we show that the proposed approach can handle complexities with nearly 90% of the detected roof faces reconstructed correctly. The approach allows complex height jumps and various types of building roofs to be firmly reconstructed without prior knowledge of primitive building types.

  17. Field Testing of an Unvented Roof with Fibrous Insulation, Tiles and Vapor Diffusion Venting

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K. [Building Science Corporation, Westford, MA (United States); Lstiburek, J. W. [Building Science Corporation, Westford, MA (United States)

    2016-02-05

    This research is a test implementation of an unvented tile roof assembly in a hot-humid climate (Orlando, FL; Zone 2A), insulated with air permeable insulation (netted and blown fiberglass). Given the localized moisture accumulation and failures seen in previous unvented roof field work, it was theorized that a 'diffusion vent' (water vapor open, but air barrier 'closed') at the highest points in the roof assembly might allow for the wintertime release of moisture, to safe levels. The 'diffusion vent' is an open slot at the ridge and hips, covered with a water-resistant but vapor open (500+ perm) air barrier membrane. As a control comparison, one portion of the roof was constructed as a typical unvented roof (self-adhered membrane at ridge). The data collected to date indicate that the diffusion vent roof shows greater moisture safety than the conventional, unvented roof design. The unvented roof had extended winter periods of 95-100% RH, and wafer (wood surrogate RH sensor) measurements indicating possible condensation; high moisture levels were concentrated at the roof ridge. In contrast, the diffusion vent roofs had drier conditions, with most peak MCs (sheathing) below 20%. In the spring, as outdoor temperatures warmed, all roofs dried well into the safe range (10% MC or less). Some roof-wall interfaces showed moderately high MCs; this might be due to moisture accumulation at the highest point in the lower attic, and/or shading of the roof by the adjacent second story. Monitoring will be continued at least through spring 2016 (another winter and spring).

  18. EXISTING PROBLEMS ANALYZIS OF ORGANIZATIONAL AND TECHNOLOGICAL RELIABILITY OF ROOFING SYSTEMS

    Directory of Open Access Journals (Sweden)

    A. V. Radkevich

    2015-03-01

    Full Text Available Purpose. The article aims at analysis of existing approaches towards engineering, construction, reconstruction and major repair of buildings roofing systems and constructions for solving the matters regarding organizational and technological reliability. Methodology. The survey is based on methods of analogy, scientific analysis and synthesis. Findings. The analysis of innovative technologies as well as new construction materials for roofing has been carried out. Problems regarding their organizational and technological reliability have been specified. Relevance of the given problems has been grounded. Correlation between reliability of constructed facility or roofing repair from thoroughly chosen technology and also construction process organization in general was determined. All the specifications influencing roofing organizational and technological reliability have been divided into primary and secondary. New methodic conception including all the constituents of roofing in the whole has been worked out. Ukrainian and European specification documents have been taking into account. Roofing organizational and technological reliability scheme considering the factors that form reliability has been suggested. An urgent need for creation of roofing model taking into consideration the innovative technologies and latest roofing materials for choosing its rational variant has been emerged. It has to meet both customers and specification documents requirements and also desired level of organizational and technological reliability. Originality. For the first time the notion of «organizational and technological reliability» has been applied to roofing. Fundamental investigation of this notion has been suggested. Roofing reliability dependence on all its components as a whole has been analyzed. New approach towards roofing problems solving conception has been developed. Practical value. The survey results may be applied at roofing engineering and

  19. Building America Case Study: Field Testing an Unvented Roof with Fibrous Insulation and Tiles, Orlando, Florida

    Energy Technology Data Exchange (ETDEWEB)

    2015-11-01

    This research is a test implementation of an unvented tile roof assembly in a hot-humid climate (Orlando, FL; Zone 2A), insulated with air permeable insulation (netted and blown fiberglass). Given the localized moisture accumulation and failures seen in previous unvented roof field work, it was theorized that a 'diffusion vent' (water vapor open, but air barrier 'closed') at the highest points in the roof assembly might allow for the wintertime release of moisture, to safe levels. The 'diffusion vent' is an open slot at the ridge and hips, covered with a water-resistant but vapor open (500+ perm) air barrier membrane. As a control comparison, one portion of the roof was constructed as a typical unvented roof (self-adhered membrane at ridge). The data collected to date indicate that the diffusion vent roof shows greater moisture safety than the conventional, unvented roof design. The unvented roof had extended winter periods of 95-100% RH, and wafer (wood surrogate RH sensor) measurements indicating possible condensation; high moisture levels were concentrated at the roof ridge. In contrast, the diffusion vent roofs had drier conditions, with most peak MCs (sheathing) below 20%. In the spring, as outdoor temperatures warmed, all roofs dried well into the safe range (10% MC or less). Some roof-wall interfaces showed moderately high MCs; this might be due to moisture accumulation at the highest point in the lower attic, and/or shading of the roof by the adjacent second story. Monitoring will be continued at least through spring 2016 (another winter and spring).

  20. Characteristic roofing slates from Spain: Mormeau and Los Molinos

    Science.gov (United States)

    Cardenes Van den Eynde, Victor; Cnudde, Veerle; Cnudde, Jean Pierre

    2014-05-01

    Characteristic roofing slates from Spain: Mormeau and Los Molinos Cardenes1, V., Cnudde1, V., Cnudde1, J.P. 1 Department of Geology and Soil Science, Ghent University, Krijgslaan 281, S8, 9000 Ghent, Belgium. The world's major roofing slate outcrops are found in the NW of Spain, in the Ordovician terrains of the domain of the Truchas Syncline. In this remote area, slate was quarried since ancient times for the use of the inhabitants of the region. Half of a century ago, an industrialization process took place in this area, which began to produce high quality roofing slate for many buildings from Japan to the USA, and especially in Europe. Since then, Spanish slate roofing has been widely used for new buildings and also for restoration of historical buildings. This work revises the occurrence and characteristics of the two most representative grey slate varieties from the Truchas Syncline, Mormeau, a fine-grained slate, and Los Molinos, also a grey slate with a slightly coarser grain. Both slates have a very similar aspect, but Mormeau slate have some iron sulphides on its composition that sometimes forms oxidation spots. Mormeau beds are found at the Middle-Upper Ordovician age Casaio Formation, while Los Molinos beds are located at the Rozadais Formation, of age Upper Ordovician, defined as formation just for the Truchas Syncline domain. Both slates have a high degree of homogeneity on their constructive characteristics, with a typical composition of quartz, mica and chlorites, and a metamorphic degree corresponding to the green schists facies. This work revises the history and characteristics of both slates, that can be considered as lithotypes that can be used as a reference during the prospection of new slate outcrops worldwide. The presented varieties of slate are proposed for their inclusion as Global Heritage Stones.