WorldWideScience

Sample records for extended power up-rate

  1. Extended Power Up-rates

    International Nuclear Information System (INIS)

    Jon Ball

    2006-01-01

    Full text of publication follows: Nuclear energy is a reliable and cost-competitive global source of power. With rising oil and gas prices, nuclear continues to provide economic and environmental benefits. Extended Power Up-rate (EPU) provides a means for existing nuclear assets to generate increased power and substantially reduce electrical generation costs. GE Energy's Nuclear Business is the global leader in boiling water reactor (BWR) technology. The experience-base of plants that have successfully achieved EPU includes Spain, Switzerland, Sweden, Germany and the United States. The GE experience-base includes fourteen BWRs with over fifty-eight reactor-years of operating experience at EPU conditions. Other than the expected plant modifications needed to accommodate higher steam flows, flow-induced vibration (FIV) has been identified as the major area of concern when up-rating. Two plants have experienced damage to their steam dryers that has lead to an extensive program to improve the understanding of the effects of up-rates. This program includes extensive in-plant data collection, the development of a scale model test facility to study components susceptible to FIV and improvements in analytical techniques for evaluating loading on reactor internals. As global energy demands increase, oil and gas prices escalate, and environmental concerns over greenhouse effects challenge us to find environmentally friendly sources of energy, Nuclear is the most viable and economical source of power in the world. With a focused effort on plant reliability, existing plants can undergo Extended Power Up-rate, and continue to meet the ever-increasing energy demands in the world. (author)

  2. Experiences of power-up rating in Taiwan

    International Nuclear Information System (INIS)

    Liao, C. C.; Lai, S. Y.; Chen, Y. B.

    2010-10-01

    Taiwan has six nuclear power reactors in operation, and two advanced reactors under construction. Measurement Uncertainty Recapture (MU R) type power up rates have been implemented for all the operating units. MU Rs are less than 2 percent and are achieved by using more advanced feedwater flow measurement devices to more precisely measure feedwater flow, which is used to calculate reactor thermal power. The other two types of power up rates are stretch power up rates (SPU) and extended power up rates (EPU). SPU are typically up to 7 percent and EPU are greater that 7 percent but less than 20%. The Atomic Energy Council (Aec) regulates the maximum thermal power level at which a nuclear power plant may operate. In order to increase the rated thermal power of a plant, utility needs to submit an application to the Aec for approval. Detailed safety analysis is required and will be thoroughly reviewed by Aec special task force to ensure the plant safety after implementing the power up rate. Important findings will be documented in the safety evaluation reports. In 2006, Tai power submitted Kuosheng nuclear power plants MU R application, which was the first power up rate application in Taiwan. Till middle of 2009, Tai power has completed the MU R project for all the existing units. The actual thermal power up rates of the six units are whit in the range of 0.3% to 1.5%, resulting in net 56.3 M We increase. Following the success of MU R, Tai power has lunched another project for SPU. In order to enhance the regulatory review process, Aec has drafted a guideline for SPU and EPU by mainly referencing U.S. experience. This guideline shall be beneficial to both licensee and regulatory body in either document preparation or safety review work for the future power up rate applications. (Author)

  3. Laguna Verde: a 120% extended power up-rate project developed by Iberdrola

    International Nuclear Information System (INIS)

    Merino Teillet, A.; Garcia-Serrano Tapia, J. L.; Ruiz Gutierrez, L.

    2010-01-01

    The experience which this document wants to present, describes the work being developed by IBERDROLA Ingenieria y Construccion, for the Laguna Verde plant in Mexico, owned by the Federal Electricity Commission (CFE). This generation plant consists of two light boiling water type units (BWR) design by General Electric in the 80's. The objective of this project is to perform the modifications on the thermal cycle of the plant required by an Extended Power Up-rate, to achieve a safe and reliable operation of the plant at 120% of its original thermal power, whilst upgrading and renovating plant equipment and installations to achieve a license renewal from 40 to 60 years of operation The consortium formed in 97% by IBERDROLA Ingenieria y Construccion SAU and in 3% by ALSTOM Mexicana, S.A. de CV, was awarded the contract in an international bid, competing against General Electric and Siemens. The project began in March 2007 and is scheduled to finalize in December 2010. At this point the work carried out include modifications of the main condenser replacement, moisture separator reheaters (MSR's) and feedwater heaters no. 5 and 6 in the two units, therefore having executed two out of four scheduled outages. The scope, development and organization of this project, whose basic elements include the design, engineering, training, supply of equipment, dismantling, installation, testing, commissioning, treatment and delivery of radioactive waste generated during the project implementation to CFE, is aimed to ensure a safe and reliable operation of the plant under the new conditions of increased thermal power of the reactor, with a thermal cycle optimized so that the gross power of the generator increase from the current 686.7 MWe to a value of 817.1 MWe in both units. An Extended Power Up-rate means an opportunity to modernize equipments, to improve maintenance, to get a better plant knowledge and to motivate the employees facing a challenging project. This project, being the

  4. Fuel and Core Design Verification for Extended Power Up-rate in Ringhals Unit 3

    International Nuclear Information System (INIS)

    Gabrielsson, Petter; Stepniewski, Marek; Almberger, Jan

    2006-01-01

    Vattenfall's Westinghouse 3-loop PWR Ringhals 3 at the western coast of Sweden is scheduled for an extended power up-rate from 2783 to 3160 MWt in 2007, in the frame of the so called GREAT-project. The project will realize an up-rating initially planned and analysed back in 1995, but with a number of significant improvements outlined in this paper. For the licensing of the up-rated power level, a complete revision of the safety analyses, radiological analyses and systems verifications in FSAR is being performed by Westinghouse Electrics Belgium. The work is performed in close cooperation with Vattenfall in the areas of core calculations and input data. For more than a decade, Vattenfall has performed all core design and reload safety evaluations (RSE) for Ringhals, independent of fuel vendors and safety analysts. In GREAT all core parameters in the safety analysis checklist (SAC) used for the safety analyses are determined based upon a set of nine reference loading patterns designed by Vattenfall covering a wide range of fuel and core designs and extreme cycle-to-cycle variations. To facilitate the calculation of SAC parameters Westinghouse has provided a Reload Safety Evaluation Procedure report (RSEP) with detailed specifications for the calculation of all core parameters used in the analyses. The procedure has been automatized by Vattenfall in a set of scripts executing 3D core simulator calculations and extracting the key results. The same tools will be used in Vattenfall's future RSE for Ringhals 3. This approach is taken to obtain consistency between core designs and core calculations for the safety analyses and the cycle specific calculations, to minimize the risk for future violations of the safety analyses. (authors)

  5. C.N. Cofrentes power up-rate up to 110 %. A challenge for cycle 14 core design

    International Nuclear Information System (INIS)

    Gomez Bernal, M.I.; Lopez Carbonell, M.T.; Garcia Delgado, L.

    2001-01-01

    C.N.Cofrentes is a GE design BWR reactor with 624 bundles in the core, a rated power of 2894 MWt and it is currently operating Cycle 13 at 104.2 % power. Commercial operation started in 1984 with 12-month cycles at rated power. Both cycle length and thermal power have been increased since then. Power has been up-rated in two steps, first at 102 % in Cycle 4 and later in Cycle 11 at 104.2%. Cycle length has been extended from the original 12-month to the currently 18-month cycles. Next cycle, Cycle 14, will be an 18-month cycle operating at 110 % power. This goal is a challenge for the in-house nuclear design team. Start up for Cycle 14 is planned for the first quarter of 2002. (author)

  6. Simulation of overpressure events with a Laguna Verde model for the RELAP code to conditions of extended power up rate

    International Nuclear Information System (INIS)

    Rodriguez H, A.; Araiza M, E.; Fuentes M, L.; Ortiz V, J.

    2012-10-01

    In this work the main results of the simulation of overpressure events are presented using a model of the nuclear power plant of Laguna Verde developed for the RELAP/SCDAPSIM code. As starting point we have the conformation of a Laguna Verde model that represents a stationary state to similar conditions to the operation of the power station with Extended Power Up rate (EPU). The transitory of simulated pressure are compared with those documented in the Final Safety Analysis Report of Laguna Verde (FSAR). The results of the turbine shot transitory with and without by-pass of the main turbine are showed, and the event of closes of all the valves of main vapor isolation. A preliminary simulation was made and with base in the results some adjustments were made for the operation with EPU, taking into account the Operation Technical Specifications of the power station. The results of the final simulations were compared and analyzed with the content in the FSAR. The response of the power station to the transitory, reflected in the model for RELAP, was satisfactory. Finally, comments about the improvement of the model are included, for example, the response time of the protection and mitigation systems of the power station. (Author)

  7. Nuclear plant power up-rate study: feedwater heater evaluations

    International Nuclear Information System (INIS)

    Svensson, Eric; Catapano, Michael; Coakley, Michael; Thomas, Dan

    2014-01-01

    Given today's nuclear industry business climate, it has become common for Utility companies to consider increasing unit capacities through turbine replacement and power up-rates. An integral part of the studies conducted by many towards this end, involve the generation of a set of turbine cycle heat balances with predicted performance parameters for the up-rated condition. Once these tentative operating values are established, it becomes necessary to evaluate the suitability of the existing components within each system to ensure they are capable of continued safe and reliable operation. The ultimate cost for the up-rate, including the cost for any major required modifications or significant replacements is weighed against increased revenue generated from the up-rate over time. Exelon's Peach Bottom Atomic Power Station (PBAPS) is currently planning for an Extended Power up-rate (EPU) for both units. To ensure the existing Feedwater Heaters (FWH) could maintain the operating and transient response margins at the EPU condition, an engineering study was conducted. Powerfect Inc. in conjunction with SPX Heat Transfer LLC were contracted to provide engineering services to analyze the design, thermal performance, reliability and operating conditions at projected EPU conditions. Specifically, to address the following with regard to the station's Feedwater Heaters (FWHs): 1. Evaluate Drain Cooler (DC) Velocities - including zone inlet velocity, cross and window velocities and outlet velocities. 2. Evaluate Drain Cooler Zone Pressure Drop for effect on drain cooler margins to flashing. 3. Evaluate differential pressure allowable across the pass partition plate. 4. Evaluate Drain Cooler Tube Vibration Potential. 5. Perform detailed steam dome velocity calculations. The goal of the study was to identify the most susceptible areas within the heaters for problems and potential failures when operating at the higher duty of the EPU condition for the remaining life

  8. Audit Calculations of LBLOCA for Ulchin Unit 1 and 2 Power Up rate

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Donggu; Huh, Byunggil; Yoo, Seunghunl; Yang, Chaeyong; Seul, Kwangwon [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2013-05-15

    The KINS-Realistic Evaluation Model (KINS-REM) was developed for the independent audit calculation in 1991, and the code accuracy and statistical method have been improved. To support the licensing review and to confirm the validity of licensee's calculation, regulatory auditing calculations have been also conducted. Currently, the modification of Ulchin 1 and 2 operating license for 4.5% power up rate is under review. In this study, the regulatory audit calculation for LBLOCA of Ulchin Unit 1 and 2 with 4.5% power up rate was performed by applying KINS-REM. In this study, the regulatory audit calculation for LBLOCA of Ulchin Unit 1 and 2 with 4.5% power up rate was performed by applying KINS-REM. It is confirmed that the analysis results of LBLOCA for Ulchin 1 and 2 power up rate meets the PCT acceptance criteria.

  9. Up-Rating - An Alternative Approach to Meeting Future Power Demands - Exploitation of Design Margins

    Energy Technology Data Exchange (ETDEWEB)

    Bruce, Barnaby; Schwarz, Thomas [AREVA NP GmbH, Freyeslebenstr. 1, 91058 Erlangen (Germany)

    2008-07-01

    Up-rating is a world-wide implemented approach that takes advantage of increased calculation and analytic abilities developed since commissioning and applies them to old plants. In doing so, what would possibly be considered today as over-engineered design margins are exploited and plant performance is improved, without necessarily involving extensive modifications or replacement of hardware. It is therefore a short-term alternative, compared to new plants, with little change in environmental ramifications for power production capacity gained. Up-rating is also more accepted by the wider community and licensing authorities, thus complimenting the building of new plants. The 10% thermal up-rating of the nuclear power plant at Almaraz, Spain, requires a comprehensive reanalysis of all power components. This paper focuses on those measures required to ensure the performance of the steam generators at increased load as an example of design margin exploitation in such crucial components. (authors)

  10. Laguna Verde after the extended power increase

    International Nuclear Information System (INIS)

    Herrera C, M. N.; Castaneda G, M. A.; Cardenas J, J. B.; Garcia de la C, F. M.

    2012-10-01

    The project of extended power increase that was implemented in both units of the nuclear power plant of Laguna Verde beginning with the stage feasibility evaluation in nuclear side of the facilities, that is to say the affectation of the power increase in the equipment s, systems and components of the nuclear power plant; besides the feasibility evaluation a study cost-benefit for the rehabilitated and modernization of the equipment s, systems and components of Plant Balance was realized. Once considered technical and economically feasible the project began the engineering evaluations required to carry out the licensing of the new operation conditions, as well as beginning to the elaboration of the technical specifications purchase of the equipment s, systems and components of the Plant Balance. While on one hand was carried out the administration of the licensing of the extended power increase for other was carried out the necessary engineering to make the physical changes in the conventional side of the nuclear power plant. Once concluded the constructive stage beginning the final stage of the project, the starting-up tests, operation and performance of the Units under the new operation conditions. This work describes this last stage that contains the technical base, the realized tests and the obtained results. (Author)

  11. Water chemistry experience following an extensive power up-rate in Oskarshamn 3 BWR

    International Nuclear Information System (INIS)

    Wegemar, Boerje; Nilsson, Jimmy; Lejon Johan; Bergfors, Asa; Arnberg, Bo

    2012-09-01

    The Swedish Oskarshamn 3 BWR plant, operated by OKG, was first connected to the grid in 1985. The plant has been power up-rated in two steps; from the original design, 3020 MWth, to 3300 MWth (109%, 1989) and recently to 3900 MWth (129%, 2009). Westinghouse Electric Sweden AB (former ASEA-Atom, OEM of the plant) was rewarded a major contract in the recently implemented up-rating project, the PULS project. The PULS project is quite unique since no operating experience has to date been reported from a similar major power up-rate in a BWR plant. Water chemistry experience from the first period of operation following the implementation of the PULS project is reported and discussed in the paper. Reported chemistry and radiochemistry measurements in feedwater (FW) and reactor water (RW) include corrosion products, activated corrosion products, dissolved oxygen and impurities like chloride, sulfate etc. Furthermore, a comparison of water quality prior to implementation of the PULS project is included. Several process systems have been modified, one of them being the condensate cleanup system (CCU), a Pre-coat filter system. The design criteria for the CCU system include the filter run-lengths, pressure drop before back-washing and requirements on water chemistry quality. The paper describes in some detail the CCU system modifications being implemented in order to fulfil the design criterion. CCU cleanup efficiency, operating temperature and influence of hydrogen peroxide on the CCU resin are all important issues being covered in the paper. As for the latter, it is well known that oxygen and hydrogen peroxide (from radiolysis in the core region) might cause partial deterioration of CCU standard cation resin resulting in increased RW sulfate concentrations. This aspect is covered in the paper as well. The reactor water cleanup system (RWCU) in Oskarshamn 3 consists of deep bed ion exchange filters (mixed bed filter). The purpose of RWCU is to maintain a low level of

  12. Numerical studies on helium cooled divertor finger mock up with sectorial extended surfaces

    International Nuclear Information System (INIS)

    Rimza, Sandeep; Satpathy, Kamalakanta; Khirwadkar, Samir; Velusamy, Karupanna

    2014-01-01

    Highlights: • Studies on heat transfer enhancement for divertor finger mock-up. • Heat transfer characteristics of jet impingement with extended surfaces have been investigated. • Effect of critical parameters that influence the thermal performance of the finger mock-up by CFD approach. • Effect of extended surface in enhancing heat removal potential with pumping power assessed. • Practicability of the chosen design is verified by structural analysis. - Abstract: Jet impinging technique is an advance divertor concept for the design of future fusion power plants. This technique is extensively used due to its high heat removal capability with reasonable pumping power and for safe operation. In this design, plasma-facing components are fabricated with numerous fingers cooled by helium jets to reduce the thermal stresses. The present study is focused towards finding an optimum performance of one such finger mock-up through systematic computational fluid dynamics (CFD) studies. Heat transfer characteristics of jet impingement have been numerically investigated with sectorial extended surfaces (SES). The result shows that addition of SES enhances heat removal potential with minimum pumping power. Detailed parametric studies on critical parameters that influence thermal performance of the finger mock-up have been analyzed. Thermo-mechanical analysis has been carried out through finite element based approach to know the state of stress in the assembly as a result of large temperature gradients. It is seen that the stresses are within the permissible limits for the present design. The whole numerical simulation has been carried out using general-purpose CFD software (ANSYS FLUENT, Release 14.0, User Guide, Ansys, Inc., 2011). Benchmark validation studies have been performed against high-heat flux experiments (B. Končar, P. Norajitra, K. Oblak, Appl. Therm. Eng., 30, 697–705, 2010) and a good agreement is noticed between the present simulation and the reported

  13. Cost of nuclear power generation judged by power rate

    International Nuclear Information System (INIS)

    Hirai, Takaharu

    1981-01-01

    According to estimation guidance, power rates in general are the proper cost plus the specific compensation and adjustment addition. However, the current system of power rates is of power-source development promotion type involving its tax. The structure of power rate determination must be restudied now especially in connection of nuclear power generation. The cost of nuclear power generation as viewed from power rate is discussed as follows: the fear of military application of power plants, rising plant construction costs, the loophole in fuel cost calculation, unreasonable unit power cost, depreciation and repair cost, business compensation, undue business compensation in nuclear power, the costs of nuclear waste management, doubt concerning nuclear power cost, personnel, pumping-up and power transmission costs in nuclear power, energy balance analysis, nuclear power viewed in entropy, the suppression of power consumption. (J.P.N.)

  14. The Modernization Program and Power Up-rate at NPP V2 Jaslovske Bohunice, Slovak Republic

    International Nuclear Information System (INIS)

    Reznik, Vladivoj; Krajmer, Imrich

    2010-01-01

    Slovenske Elektrarne, a.s. is a second largest utility company in the Central and Eastern Europe that owns an optimal production portfolio comprised of nuclear, thermal and hydroelectric power plants. There are two nuclear power plants Bohunice and Mochovce both operate with two units and another two units Mochovce 3 and 4 are currently under construction. Electricity at Nuclear power plant Bohunice V2 is generated by two 440 MW units that had gradually been connected to the power network over the period between 1984 and 1985. In the construction of the nuclear power plant V2 the concept of pressurized water reactors was adopted and the Soviet-era design WWER 440 used. The upgrading of Nuclear Power Plant Bohunice V2 is based on three main points: Modernization, Power up-rate, and Ageing monitoring program. The main targets of the modernization project were: Increasing of the Nuclear Safety and of the Nuclear operational reliability, and Seismic improvement. This modernization program is in full compliance with IAEA requirements and with the decisions from the Nuclear Regulatory Agency of the Slovak Republic (UJD) and achievement of the probabilistic safety criteria in accordance with IAEA recommendations. Except that is ensured a safe, reliable, economical and effective electricity and heat generation. Achieved results are based for further prolongation of the operation life time up to 60 years. (authors)

  15. Simulation of overpressure events with a Laguna Verde model for the RELAP code to conditions of extended power up rate; Simulacion de eventos de sobrepresion con un modelo de Laguna Verde para el codigo RELAP a condiciones de aumento de potencia extendido

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez H, A.; Araiza M, E.; Fuentes M, L.; Ortiz V, J., E-mail: andres.rodriguez@inin.gob.mx [ININ, Departamento de Sistemas Nucleares, Carretera Mexico-Toluca s/n, 52750 Ocoyoacac, Estado de Mexico (Mexico)

    2012-10-15

    In this work the main results of the simulation of overpressure events are presented using a model of the nuclear power plant of Laguna Verde developed for the RELAP/SCDAPSIM code. As starting point we have the conformation of a Laguna Verde model that represents a stationary state to similar conditions to the operation of the power station with Extended Power Up rate (EPU). The transitory of simulated pressure are compared with those documented in the Final Safety Analysis Report of Laguna Verde (FSAR). The results of the turbine shot transitory with and without by-pass of the main turbine are showed, and the event of closes of all the valves of main vapor isolation. A preliminary simulation was made and with base in the results some adjustments were made for the operation with EPU, taking into account the Operation Technical Specifications of the power station. The results of the final simulations were compared and analyzed with the content in the FSAR. The response of the power station to the transitory, reflected in the model for RELAP, was satisfactory. Finally, comments about the improvement of the model are included, for example, the response time of the protection and mitigation systems of the power station. (Author)

  16. Radiation monitoring data on the power-up test of HTTR. Results up to 20 MW operation

    International Nuclear Information System (INIS)

    Ashikagaya, Yoshinobu; Nakazawa, Takashi; Yoshino, Toshiaki; Yasu, Katsuji

    2002-01-01

    The High Temperature Engineering Test Reactor (HTTR) have completed the Power-up test of 9 MW (the single and parallel loaded operation) in the rated operation mode. After that the Power-up test in the rated operation mode and the high-temperature test operation mode with a thermal output of 20 MW (the single and parallel loaded operation) were performed between January 16, 2001 and June 10, 2001. This report describes the radiation monitoring data carried out during the HTTR Power-up test in the rated operation mode and the high-temperature test operation mode with a thermal output of 20 MW. The followings were concluded from these radiation monitoring data. The monitoring of radioactive gaseous effluents and the radiation protection for the works will be easy to do and the exposure dose of the workers will be kept the low level. (author)

  17. 2007 Wholesale Power Rate Schedules : 2007 General Rate Schedule Provisions.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    2006-11-01

    This schedule is available for the contract purchase of Firm Power to be used within the Pacific Northwest (PNW). Priority Firm (PF) Power may be purchased by public bodies, cooperatives, and Federal agencies for resale to ultimate consumers, for direct consumption, and for Construction, Test and Start-Up, and Station Service. Rates in this schedule are in effect beginning October 1, 2006, and apply to purchases under requirements Firm Power sales contracts for a three-year period. The Slice Product is only available for public bodies and cooperatives who have signed Slice contracts for the FY 2002-2011 period. Utilities participating in the Residential Exchange Program (REP) under Section 5(c) of the Northwest Power Act may purchase Priority Firm Power pursuant to the Residential Exchange Program. Rates under contracts that contain charges that escalate based on BPA's Priority Firm Power rates shall be based on the three-year rates listed in this rate schedule in addition to applicable transmission charges. This rate schedule supersedes the PF-02 rate schedule, which went into effect October 1, 2001. Sales under the PF-07 rate schedule are subject to BPA's 2007 General Rate Schedule Provisions (2007 GRSPs). Products available under this rate schedule are defined in the 2007 GRSPs. For sales under this rate schedule, bills shall be rendered and payments due pursuant to BPA's 2007 GRSPs and billing process.

  18. Nuclear power/water pumping-up composite power plant

    International Nuclear Information System (INIS)

    Okamura, Kiyoshi.

    1995-01-01

    In a nuclear power/water pumping-up composite power plant, a reversible pump for pumping-up power generation connected to a steam turbine is connected to an upper water reservoir and a lower water reservoir. A pumping-up steam turbine for driving the turbine power generator, a hydraulic pump for driving water power generator by water flowing from the upper water reservoir and a steam turbine for driving the pumping-up pump by steams from a nuclear reactor are disposed. When power demand is small during night, the steam turbine is rotated by steams of the reactor, to pump up the water in the lower water reservoir to the upper water reservoir by the reversible pump. Upon peak of power demand during day time, power is generated by the steams of the reactor, as well as the reversible pump is rotated by the flowing water from the upper water reservoir to conduct hydraulic power generation. Alternatively, hydraulic power generation is conducted by flowing water from the upper reservoir. Since the number of energy conversion steps in the combination of nuclear power generation and pumping-up power generation is reduced, energy loss is reduced and utilization efficiency can be improved. (N.H.)

  19. Nanosecond pulsed power generator for a voltage amplitude up to 300 kV and a repetition rate up to 16 Hz for fine disintegration of quartz

    Energy Technology Data Exchange (ETDEWEB)

    Krastelev, E. G., E-mail: ekrastelev@yandex.ru; Sedin, A. A.; Tugushev, V. I. [Russian Academy of Sciences, Joint Institute for High Temperatures (Russian Federation)

    2015-12-15

    A generator of high-power high-voltage nanosecond pulses is intended for electrical discharge disintegration of mineral quartz and other nonconducting minerals. It includes a 320 kV Marx pulsed voltage generator, a high-voltage glycerin-insulated coaxial peaking capacitor, and an output gas spark switch followed by a load, an electric discharge disintegration chamber. The main parameters of the generator are as follows: a voltage pulse amplitude of up to 300 kV, an output impedance of ≈10 Ω, a discharge current amplitude of up to 25 kA for a half-period of 80–90 ns, and a pulse repetition rate of up to 16 Hz.

  20. Nanosecond pulsed power generator for a voltage amplitude up to 300 kV and a repetition rate up to 16 Hz for fine disintegration of quartz

    International Nuclear Information System (INIS)

    Krastelev, E. G.; Sedin, A. A.; Tugushev, V. I.

    2015-01-01

    A generator of high-power high-voltage nanosecond pulses is intended for electrical discharge disintegration of mineral quartz and other nonconducting minerals. It includes a 320 kV Marx pulsed voltage generator, a high-voltage glycerin-insulated coaxial peaking capacitor, and an output gas spark switch followed by a load, an electric discharge disintegration chamber. The main parameters of the generator are as follows: a voltage pulse amplitude of up to 300 kV, an output impedance of ≈10 Ω, a discharge current amplitude of up to 25 kA for a half-period of 80–90 ns, and a pulse repetition rate of up to 16 Hz

  1. Method of operating BWR type power plants

    International Nuclear Information System (INIS)

    Koyama, Kazuaki.

    1981-01-01

    Purpose: To improve the operation efficiency of BWR type reactors by reducing the time from the start-up of the reactor to the start-up of the turbine and electrical generator, as well as decrease the pressure difference in each of the sections of the pressure vessel to thereby extend its life span. Method: The operation comprises switching the nuclear reactor from the shutdown mode to the start-up mode, increasing the reactor power to a predetermined level lower than a rated power while maintaining the reactor pressure to a predetermined level lower than a rated pressure, starting up a turbine and an electrical generator in the state of the predetermined reactor pressure and the reactor power to connect the electrical generator to the power transmission system and, thereafter, increasing the reactor pressure and the reactor power to the predetermined rated pressure and rated power respectively. This can shorten the time from the start-up of the reactor to the start of the power transmission system, whereby the operation efficiency of the power plant can be improved. (Moriyama, K.)

  2. Extended heart failure clinic follow-up in low-risk patients

    DEFF Research Database (Denmark)

    Schou, Morten; Gustafsson, Finn; Videbaek, Lars

    2013-01-01

    BackgroundOutpatient follow-up in specialized heart failure clinics (HFCs) is recommended by current guidelines and implemented in most European countries, but the optimal duration of HFC programmes has not been established. Nor is it known whether all or only high-risk patients, e.g. identified...... by NT-proBNP, might benefit from an extended HFC follow-up.Methods and resultsIn a multi-centre setting, we randomly assigned 921 clinically stable systolic heart failure (HF) outpatients on optimal medical therapy to undergo either an extended follow-up in the HFC (n = 461) or referral back...

  3. Novel start-up circuit with enhanced power-up characteristic for bandgap references

    DEFF Research Database (Denmark)

    Tuan Vu, Cao; Wisland, Dag T.; Lande, Tor Sverre

    This paper presents a new start-up circuit for low-power bandgap reference (BGR) voltage generators. The BGR is designed for providing a stable 0.3 V power supply for application in low power wireless sensor nodes. The BGR has an enhanced power-up characteristic and demonstrates a reduction...... of the total stand-by current. Simulated results confirm that the proposed start-up circuit does not affect the performance of the BGR even though the supply voltage (VDD) is higher and has more stable power-up characteristic than the conventional start-up circuits. The new start-up circuit is designed with 65...

  4. Sensitivity change of rhodium self -powered detectors with burn-up

    International Nuclear Information System (INIS)

    Girgis, R.; Akimov, I.S.; Hamouda, I.

    1976-01-01

    The scope of the present paper is to obtain the calculation formulae to evaluate the rate of sensitivity change of the neutron self-powered detectors with burn-up. A code written in FORTRAN 4 was developed to be operational on the IBM-1130 computer. It has been established in the case of rhodium detectors that neglecting the β-particle absorption in the calculations leads to the underestimation of the detector sensitivity decrease up to 40%. The derived formulae can be used for other self-powered detectors. (author)

  5. An Extended System Frequency Response Model Considering Wind Power Participation in Frequency Regulation

    Directory of Open Access Journals (Sweden)

    Yi Tang

    2017-11-01

    Full Text Available With increasing penetration of wind power into the power system, wind power participation in frequency regulation is regarded as a beneficial strategy to improve the dynamic frequency response characteristics of power systems. The traditional power system frequency response (SFR model, which only includes synchronous generators, is no longer suitable for power systems with high penetrated wind power. An extended SFR model, based on the reduced-order model of wind turbine generator (WTG and the traditional SFR model, is presented in this paper. In the extended SFR model, the reduced-order model of WTG with combined frequency control is deduced by employing small signal analysis theory. Afterwards, the stability analysis of a closed-loop control system for the extended SFR model is carried out. Time-domain simulations using a test system are performed to validate the effectiveness of the extended SFR model; this model can provide a simpler, clearer and faster way to analyze the dynamic frequency response characteristic for a high-wind integrated power systems. The impact of additional frequency control parameters and wind speed disturbances on the system dynamic frequency response characteristics are investigated.

  6. Sector 7-8 powered up

    CERN Document Server

    2007-01-01

    1. Frédéric Gicquel from the Cryogenics for Accelerators Group (AT/ACR) and Anupama Kulkarni from the Magnets and Electrical Systems Group (AT/MEL) at the CERN Control Centre during the powering-up of Sector 7-8. 2. Frédérick Bordry, leader of the Power Converter Group (AB/PO), and Roberto Saban, responsible for coordinating the LHC commissioning (TS/HDO), celebrate the end of the first powering-up of an entire LHC sector: Sector 7-8.

  7. Mortality risk in the french cohort of uranium miners: extended follow-up 1946-1999

    International Nuclear Information System (INIS)

    Blandine Vacquier; Dominique Laurier; Sylvaine Caer; Benoit Quesne

    2006-01-01

    Since the 1970's, exposure to radon and to its radioactive decay products has been studied in relation to lung cancer risk among cohorts of miners [1-3]. These studies concluded that cumulative exposure to radon was associated with an increased risk of death from lung cancer. In 1988, the International Agency for Research on Cancer (IARC) classified radon as a known pulmonary human carcinogen [4]. The French cohort of uranium miners has been established in order to assess the mortality risk of miners exposed to low levels of radon and its decay products as well as to other occupational hazards. The primary aim of the cohort study is the quantification of the relationship between cumulated radon exposure and risk of lung cancer death. The study has been conducted by the Institut de Radioprotection et de Surete Nucleaire (IRSN) since 1982, in collaboration with the Occupational Medical Service of COGEMA. The French Data Protection Authority (CNIL) gave approval for this study. Previous analyses have demonstrated an excess of lung cancer death associated with radon exposure. These results regarding lung cancer have been presented in several publications and congress [5-11]. In 2004, the follow-up of this cohort was extended from 31 December 1994 through 31 December 1999. The extension of the follow-up increases the statistical power of the cohort. The present article describes the extended cohort and the analysis of mortality based on the follow-up of the cohort to end of 1999. (authors)

  8. Extended Kalman Filtering to estimate temperature and irradiation for maximum power point tracking of a photovoltaic module

    International Nuclear Information System (INIS)

    Docimo, D.J.; Ghanaatpishe, M.; Mamun, A.

    2017-01-01

    This paper develops an algorithm for estimating photovoltaic (PV) module temperature and effective irradiation level. The power output of a PV system depends directly on both of these states. Estimating the temperature and irradiation allows for improved state-based control methods while eliminating the need of additional sensors. Thermal models and irradiation estimators have been developed in the literature, but none incorporate feedback for estimation. This paper outlines an Extended Kalman Filter for temperature and irradiation estimation. These estimates are, in turn, used within a novel state-based controller that tracks the maximum power point of the PV system. Simulation results indicate this state-based controller provides up to an 8.5% increase in energy produced per day as compared to an impedance matching controller. A sensitivity analysis is provided to examine the impact state estimate errors have on the ability to find the optimal operating point of the PV system. - Highlights: • Developed a temperature and irradiation estimator for photovoltaic systems. • Designed an Extended Kalman Filter to handle model and measurement uncertainty. • Developed a state-based controller for maximum power point tracking (MPPT). • Validated combined estimator/controller algorithm for different weather conditions. • Algorithm increases energy captured up to 8.5% over traditional MPPT algorithms.

  9. Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) : Part 2: cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)

    CERN Document Server

    International Electrotechnical Commission. Geneva

    2005-01-01

    Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) : Part 2: cables for rated voltages from 6 kV (Um = 7,2 kV) up to 30 kV (Um = 36 kV)

  10. A simple approximation of moments of the quasi-equilibrium distribution of an extended stochastic theta-logistic model with non-integer powers.

    Science.gov (United States)

    Bhowmick, Amiya Ranjan; Bandyopadhyay, Subhadip; Rana, Sourav; Bhattacharya, Sabyasachi

    2016-01-01

    The stochastic versions of the logistic and extended logistic growth models are applied successfully to explain many real-life population dynamics and share a central body of literature in stochastic modeling of ecological systems. To understand the randomness in the population dynamics of the underlying processes completely, it is important to have a clear idea about the quasi-equilibrium distribution and its moments. Bartlett et al. (1960) took a pioneering attempt for estimating the moments of the quasi-equilibrium distribution of the stochastic logistic model. Matis and Kiffe (1996) obtain a set of more accurate and elegant approximations for the mean, variance and skewness of the quasi-equilibrium distribution of the same model using cumulant truncation method. The method is extended for stochastic power law logistic family by the same and several other authors (Nasell, 2003; Singh and Hespanha, 2007). Cumulant truncation and some alternative methods e.g. saddle point approximation, derivative matching approach can be applied if the powers involved in the extended logistic set up are integers, although plenty of evidence is available for non-integer powers in many practical situations (Sibly et al., 2005). In this paper, we develop a set of new approximations for mean, variance and skewness of the quasi-equilibrium distribution under more general family of growth curves, which is applicable for both integer and non-integer powers. The deterministic counterpart of this family of models captures both monotonic and non-monotonic behavior of the per capita growth rate, of which theta-logistic is a special case. The approximations accurately estimate the first three order moments of the quasi-equilibrium distribution. The proposed method is illustrated with simulated data and real data from global population dynamics database. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Active and reactive power sharing and frequency restoration in a distributed power system consisting of two UPS units

    Energy Technology Data Exchange (ETDEWEB)

    Parlak, Koray Sener; Oezdemir, Mehmet [Dept. of Electrical and Electronic Engineering, Firat University, Elazig, 23119 (Turkey); Aydemir, M. Timur [Dept. of Electrical and Electronic Engineering, Gazi University, Maltepe-Ankara 06570 (Turkey)

    2009-06-15

    A distributed power system consisting of two uninterrupted power supplies (UPS) is investigated in this paper. Parallel operation of the two sources increases the established power rating of the system. One of the sources can supply the system even when the other system is disconnected due to some faults, and this is an important feature. The control algorithm makes sure that the total load is shared between the supplies in accordance with their rated power levels, and the frequency of the supplies are restored to the rated values after the transitions. As the UPSs operate at an optimum power level, losses and faults due to overloading are prevented. The units safely operate without any means of communication between each other. The focus of the work is on the inverter stages of the UPSs. Simulations performed in Matlab Simulink environment have been verified with experimental work via DS1103 controller card. (author)

  12. Enhanced Rate Capability of Oxide Coated Lithium Titanate within Extended Voltage Ranges

    Energy Technology Data Exchange (ETDEWEB)

    Ahn, Dongjoon [College of Engineering, University of Kentucky, Lexington, KY (United States); Xiao, Xingcheng, E-mail: xingcheng.xiao@gm.com [Chemical and Materials Systems Laboratory, General Motors R& D Center, Warren, MI (United States)

    2015-06-30

    Lithium titanate (Li{sub 4}Ti{sub 5}O{sub 12} or LTO) is a promising negative electrode material of high-power lithium-ion batteries, due to its superior rate capability and excellent capacity retention. However, the specific capacity of LTO is less than one half of that of graphite electrode. In this work, we applied ultrathin oxide coating on LTO by the atomic layer deposition technique, aiming for increasing the energy density by extending the cell voltage window and specific capacity of LTO. We demonstrated that a few nanometer thick Al{sub 2}O{sub 3} coating can suppress the mechanical distortion of LTO cycled at low potential, which enable the higher specific capacity and excellent capacity retention. Furthermore, the surface coating can facilitate the charge transfer, leading to significantly improved rate capabilities, comparing with the uncoated LTO.

  13. A Comprehensive Prediction Model of Hydraulic Extended-Reach Limit Considering the Allowable Range of Drilling Fluid Flow Rate in Horizontal Drilling.

    Science.gov (United States)

    Li, Xin; Gao, Deli; Chen, Xuyue

    2017-06-08

    Hydraulic extended-reach limit (HERL) model of horizontal extended-reach well (ERW) can predict the maximum measured depth (MMD) of the horizontal ERW. The HERL refers to the well's MMD when drilling fluid cannot be normally circulated by drilling pump. Previous model analyzed the following two constraint conditions, drilling pump rated pressure and rated power. However, effects of the allowable range of drilling fluid flow rate (Q min  ≤ Q ≤ Q max ) were not considered. In this study, three cases of HERL model are proposed according to the relationship between allowable range of drilling fluid flow rate and rated flow rate of drilling pump (Q r ). A horizontal ERW is analyzed to predict its HERL, especially its horizontal-section limit (L h ). Results show that when Q min  ≤ Q r  ≤ Q max (Case I), L h depends both on horizontal-section limit based on rated pump pressure (L h1 ) and horizontal-section limit based on rated pump power (L h2 ); when Q min  drilling fluid flow rate, while L h2 keeps decreasing as the drilling fluid flow rate increases. The comprehensive model provides a more accurate prediction on HERL.

  14. Rating leniency and halo in multisource feedback ratings: testing cultural assumptions of power distance and individualism-collectivism.

    Science.gov (United States)

    Ng, Kok-Yee; Koh, Christine; Ang, Soon; Kennedy, Jeffrey C; Chan, Kim-Yin

    2011-09-01

    This study extends multisource feedback research by assessing the effects of rater source and raters' cultural value orientations on rating bias (leniency and halo). Using a motivational perspective of performance appraisal, the authors posit that subordinate raters followed by peers will exhibit more rating bias than superiors. More important, given that multisource feedback systems were premised on low power distance and individualistic cultural assumptions, the authors expect raters' power distance and individualism-collectivism orientations to moderate the effects of rater source on rating bias. Hierarchical linear modeling on data collected from 1,447 superiors, peers, and subordinates who provided developmental feedback to 172 military officers show that (a) subordinates exhibit the most rating leniency, followed by peers and superiors; (b) subordinates demonstrate more halo than superiors and peers, whereas superiors and peers do not differ; (c) the effects of power distance on leniency and halo are strongest for subordinates than for peers and superiors; (d) the effects of collectivism on leniency were stronger for subordinates and peers than for superiors; effects on halo were stronger for subordinates than superiors, but these effects did not differ for subordinates and peers. The present findings highlight the role of raters' cultural values in multisource feedback ratings. PsycINFO Database Record (c) 2011 APA, all rights reserved

  15. A novel high voltage start up circuit for an integrated switched mode power supply

    Energy Technology Data Exchange (ETDEWEB)

    Hu Hao; Chen Xingbi, E-mail: huhao21@uestc.edu.c [State Key Laboratory of Electronic Thin Films and Integrated Devices, University of Electronic Science and Technology of China, Chengdu 610054 (China)

    2010-09-15

    A novel high voltage start up circuit for providing an initial bias voltage to an integrated switched mode power supply (SMPS) is presented. An enhanced mode VDMOS transistor, the gate of which is biased by a floating p-island, is used to provide start up current and sustain high voltage. An NMOS transistor having a high source to ground breakdown voltage is included to extend the bias voltage range to the SMPS. Simulation results indicate that the high voltage start up circuit can start and restart as designed. The proposed structure is believed to be more energy saving and cost-effective compared with other solutions. (semiconductor devices)

  16. Power Minimization of a Wireless Sensor Node under Different Rate Constraints

    KAUST Repository

    Solares, Jose

    2016-03-31

    Future wireless networks are expected to handle a huge number of devices, including sensors, within a low energy consumption. In this scope, we present, in this paper, performance of wireless sensor networks (WSN). Specifically, we aim at finding the optimal transmit power of a node communicating with multiple receivers in a cognitive radio (CR) spectrum sharing framework, i.e., existence of an active primary user. We first present the optimal power with single secondary receiver, under instantaneous or average transmission rate constraints. Then, we propose a suboptimal solution for an easier, yet efficient, implementation and perform insightful asymptotical analysis for both schemes with Rayleigh fading. Afterwards, we extend our results to a multiple secondary receives CR scenario and present the corresponding optimal and suboptimal transmit power while satisfying independent peak/average and sum of peak/average transmission rate constraints. The corresponding numerical results are provided for Rayleigh and Nakagami-m fading channels. We characterize some transmission outage events depending on system parameters.

  17. Power Minimization of a Wireless Sensor Node under Different Rate Constraints

    KAUST Repository

    Solares, Jose; Sboui, Lokman; Rezki, Zouheir; Alouini, Mohamed-Slim

    2016-01-01

    Future wireless networks are expected to handle a huge number of devices, including sensors, within a low energy consumption. In this scope, we present, in this paper, performance of wireless sensor networks (WSN). Specifically, we aim at finding the optimal transmit power of a node communicating with multiple receivers in a cognitive radio (CR) spectrum sharing framework, i.e., existence of an active primary user. We first present the optimal power with single secondary receiver, under instantaneous or average transmission rate constraints. Then, we propose a suboptimal solution for an easier, yet efficient, implementation and perform insightful asymptotical analysis for both schemes with Rayleigh fading. Afterwards, we extend our results to a multiple secondary receives CR scenario and present the corresponding optimal and suboptimal transmit power while satisfying independent peak/average and sum of peak/average transmission rate constraints. The corresponding numerical results are provided for Rayleigh and Nakagami-m fading channels. We characterize some transmission outage events depending on system parameters.

  18. Piping hydrodynamic loads for a PWR power up-rate with steam generator replacement

    International Nuclear Information System (INIS)

    Julie M Jarvis; Allen T Vieira; James M Gilmer

    2005-01-01

    Full text of publication follows: Pipe break hydrodynamic loads are calculated for various systems in a PWR for a Power Up-rate (PUR) with a Steam Generator Replacement (SGR). PUR with SGR can change the system pressures, mass flowrates and pipe routing/configuration. These changes can alter the steam generator piping steam/water hammer loads. This paper discusses the need to benchmark against the original design basis, the use of different modeling techniques, and lessons learned. Benchmarking for licensing in the United States is vital in consideration of 10CFR50.59 and other licensing and safety issues. RELAP5 and its force post-processor R5FORCE are used to model the transient loads for various piping systems such as main feedwater and blowdown systems. Other modeling applications, including the Bechtel GAFT program, are used to evaluate loadings in the main steam piping. Forces are calculated for main steam turbine stop valve closure, feedwater pipe breaks and subsequent check valve slam, and blowdown isolation valve closure. These PUR/SGR forces are compared with the original design basis forces. Modeling techniques discussed include proper valve closure modeling, sonic velocity changes due to pipe material changes, and two phase flow effects. Lessons learned based on analyses done for several PWR PUR with SGR are presented. Lessons learned from these analyses include choosing the optimal replacement piping size and routing to improve system performance without resulting in excessive piping loads. (authors)

  19. Performance Model for High-Power Lithium Titanate Oxide Batteries based on Extended Characterization Tests

    DEFF Research Database (Denmark)

    Stroe, Ana-Irina; Swierczynski, Maciej Jozef; Stroe, Daniel Ioan

    2015-01-01

    Lithium-ion (Li-ion) batteries are found nowadays not only in portable/consumer electronics but also in more power demanding applications, such as stationary renewable energy storage, automotive and back-up power supply, because of their superior characteristics in comparison to other energy...... storage technologies. Nevertheless, prior to be used in any of the aforementioned application, a Li-ion battery cell must be intensively characterized and its behavior needs to be understood. This can be realized by performing extended laboratory characterization tests and developing Li-ion battery...... performance models. Furthermore, accurate performance models are necessary in order to analyze the behavior of the battery cell under different mission profiles, by simulation; thus, avoiding time and cost demanding real life tests. This paper presents the development and the parametrization of a performance...

  20. Optimal Power Allocation of a Wireless Sensor Node under Different Rate Constraints

    KAUST Repository

    Solares, Jose

    2011-07-01

    Wireless sensor networks consist of the placement of sensors over a broad area in order to acquire data. Depending on the application, different design criteria should be considered in the construction of the sensors but among all of them, the battery life-cycle is of crucial interest. Power minimization is a problem that has been addressed from different approaches which include an analysis from an architectural perspective and with bit error rate and/or discrete instantaneous transmission rate constraints, among others. In this work, the optimal transmit power of a sensor node while satisfying different rate constraints is derived. First, an optimization problem with an instantaneous transmission rate constraint is addressed. Next, the optimal power is analyzed, but now with an average transmission rate constraint. The optimal solution for a class of fading channels, in terms of system parameters, is presented and a suboptimal solution is also proposed for an easier, yet efficient, implementation. Insightful asymptotical analysis for both schemes, considering a Rayleigh fading channel, are shown. Furthermore, the optimal power allocation for a sensor node in a cognitive radio environment is analyzed where an optimum solution for a class of fading channels is again derived. In all cases, numerical results are provided for either Rayleigh or Nakagami-m fading channels. The results obtained are extended to scenarios where we have either one transmitter-multiple receivers or multiple transmitters-one receiver.

  1. Canadian breast implant cohort: extended follow-up of cancer incidence.

    Science.gov (United States)

    Pan, Sai Yi; Lavigne, Eric; Holowaty, Eric J; Villeneuve, Paul J; Xie, Lin; Morrison, Howard; Brisson, Jacques

    2012-10-01

    Cosmetic breast implants are not associated with increased breast cancer incidence, but variations of risk according to implant characteristics are still poorly understood. As well, the assessment of cancer risk for sites other than breast needs to be clarified. The purpose of this study was to fill these research gaps. This study presents an extended analysis of 10 more years of follow-up of a large Canadian cohort of women who received either cosmetic breast implants (n = 24,558) or other cosmetic surgery (15,893). Over 70% of the implant cohort was followed for over 20 years. Cancer incidence among implant women was compared to those of controls using multivariate Poisson models and the general female population using the standardized incidence ratios (SIRs). Women with breast implants had reduced rates of breast and endometrial cancers compared to other surgery women. Subglandular implants were associated to a reduced rate of breast cancer compared to submuscular implants [incidence rate ratio (IRR) = 0.78, 95% confidence interval (CI) = 0.63-0.96] and this reduction persisted over time. We observed a sevenfold increased rate (IRR = 7.36, 95% CI = 1.86-29.12) of breast cancer in the first 5 years after the date of surgery for polyurethane-coated subglandular implant women but this IRR decreased progressively over time (p value for trend = 0.02). We also observed no increased risk of rarer forms of cancer among augmented women. A reduction in breast cancer incidence was observed for women with subglandular implants relative to women with submuscular implants. Possible increase of breast cancer incidence shortly after breast augmentation with polyurethane implants needs to be verified. Copyright © 2012 UICC.

  2. Warm-up Practices in Elite Boxing Athletes: Impact on Power Output.

    Science.gov (United States)

    Cunniffe, Brian; Ellison, Mark; Loosemore, Mike; Cardinale, Marco

    2017-01-01

    Cunniffe, B, Ellison, M, Loosemore, M, and Cardinale, M. Warm-up practices in elite boxing athletes: Iimpact on power output. J Strength Cond Res 31(1): 95-105, 2017-This study evaluated the performance impact of routine warm-up strategies in elite Olympic amateur boxing athletes and physiological implications of the time gap (GAP) between warm-up and boxing activity. Six male boxers were assessed while performing standardized prefight warm-up routines. Core and skin temperature measurements (Tcore and Tskin), heart rate, and upper- and lower-body power output (PO) were assessed before and after warm-up, during a 25-minutes GAP and after 3 × 2 minutes rounds of sparring. Reflected temperature (Tc) was also determined using high-resolution thermal images at fixed time-points to explore avenues for heat loss. Despite individual differences in warm-up duration (range 7.4-18.5 minutes), increases in Tcore and Tskin occurred (p ≤ 0.05). Corresponding increases (4.8%; p ≤ 0.05) in countermovement jump (CMJ) height and upward-rightward shifts in upper-body force-velocity and power-velocity curves were observed. Athletes remained inactive during the 25-minutes GAP with a gradual and significant increase in Tc occurring by the end of GAP suggesting the likelihood of heat loss. Decreases in CMJ height and upper-body PO were observed after 15 minutes and 25 minutes GAP (p ≤ 0.05). By the end of GAP period, all performance variables had returned to pre-warm-up values. Results suggest routine warm-ups undertaken by elite boxers have acute effects on power-generating capacity. Gradual decreases in performance variables are evident with inactivity and seem related to alterations in body temperature. Considering the constraints of major competitions and time spent in air conditioned holding areas before fights, practitioners should be aware of the potential of nullifying the warm-up effects.

  3. Lithium-ion backup batteries for coping extended loss of AC power (ELAP)

    International Nuclear Information System (INIS)

    Chang, Choong-koo

    2017-01-01

    Per NRC Regulations Title 10, Code of Federal Regulations (CFR) 50.63 'Loss of all alternating current power' all Korean nuclear power plants have a coping capability for SBO conditions for a limited time ranging from approximately eight (8) to sixteen (16) hours. The 125V DC systems are designed for eight (8) hours range except Class 1E channel A and B 125V DC system of which duty cycle is 2 hours in APR1400. The strategies proposed by this paper for coping extended loss of AC power (ELAP) involve a three-phase approach. In the first extend class 1E batteries' backup time until 24 hours. Then augment class 1E batteries with Lithium-ion batteries by 72 hours from the event initiation. In addition, obtain additional capability and redundancy from off-site equipment until power systems are restored or commissioned. (author)

  4. 40 CFR 1033.140 - Rated power.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Rated power. 1033.140 Section 1033.140... EMISSIONS FROM LOCOMOTIVES Emission Standards and Related Requirements § 1033.140 Rated power. This section describes how to determine the rated power of a locomotive for the purposes of this part. (a) A locomotive...

  5. Extending OFDM Symbols to Reduce Power Consumption

    NARCIS (Netherlands)

    Kokkeler, Andre B.J.; Smit, Gerardus Johannes Maria

    2012-01-01

    Existing communication standards have limited capabilities to adapt to low SNR environments or to exploit low data rate requirements in a power efficient way. Existing techniques like e.g. control coding do not reduce the computational load when reducing data rates. In this paper, we introduce

  6. Oral L-menthol reduces thermal sensation, increases work-rate and extends time to exhaustion, in the heat at a fixed rating of perceived exertion.

    Science.gov (United States)

    Flood, T R; Waldron, M; Jeffries, O

    2017-07-01

    The study investigated the effect of a non-thermal cooling agent, L-menthol, on exercise at a fixed subjective rating of perceived exertion (RPE) in a hot environment. Eight male participants completed two trials at an exercise intensity between 'hard' and 'very hard', equating to 16 on the RPE scale at ~35 °C. Participants were instructed to continually adjust their power output to maintain an RPE of 16 throughout the exercise trial, stopping once power output had fallen by 30%. In a randomized crossover design, either L-menthol or placebo mouthwash was administered prior to exercise and at 10 min intervals. Power output, [Formula: see text]O 2 , heart rate, core and skin temperature was monitored, alongside thermal sensation and thermal comfort. Isokinetic peak power sprints were conducted prior to and immediately after the fixed RPE trial. Exercise time was greater (23:23 ± 3:36 vs. 21:44 ± 2:32 min; P = 0.049) and average power output increased (173 ± 24 vs. 167 ± 24 W; P = 0.044) in the L-menthol condition. Peak isokinetic sprint power declined from pre-post trial in the L-menthol l (9.0%; P = 0.015) but not in the placebo condition (3.4%; P = 0.275). Thermal sensation was lower in the L-menthol condition (P = 0.036), despite no changes in skin or core temperature (P > 0.05). These results indicate that a non-thermal cooling mouth rinse lowered thermal sensation, resulting in an elevated work rate, which extended exercise time in the heat at a fixed RPE.

  7. Total dose and dose-rate effects on start-up current in anti-fuse FPGA

    International Nuclear Information System (INIS)

    Wang, J.; Wong, W.; McCollum, J.; Cronquist, B.; Katz, R.; Kleyner, I.; Kleyner, F.

    1999-01-01

    Radiation enhanced start-up current (RESC) in an anti-fuse FPGA, A1280A, is thoroughly investigated and a comprehensive transistor-level mechanism is proposed. Low dose-rate testing, appropriate for civilian space applications, and annealing at room temperature shows RESC to be negligible for the lot of parts tested with a fixed power supply slew rate. (authors)

  8. Validation of the thermal balance of Laguna Verde turbine under conditions of extended power increase

    International Nuclear Information System (INIS)

    Castaneda G, M. A.; Cruz B, H. J.; Mercado V, J. J.; Cardenas J, J. B.; Garcia de la C, F. M.

    2012-10-01

    The present work is a continuation of the task: Modeling of the vapor cycle of Laguna Verde with the PEPSE code to conditions of thermal power licensed at present (2027 MWt) in which the modeling of the vapor cycle of the nuclear power plant of Laguna Verde was realized with PEPSE code (Performance Evaluation of Power System Efficiencies). Once reached the conditions of nominal operation of extended power increase, operating both units to 2371 MWt; after the tests phase of starting-up and operation is necessary to carry out a verification of the proposed design of the vapor cycle for the new operation conditions. All this, having in consideration that the vapor cycle designer only knows the detail of the prospective performance of the main turbine, for all the other components (for example pumps, heat inter changers, valves, reactor, humidity separators and re-heaters, condensers, etc.) makes generic suppositions based on engineering judgment. This way carries out the calculations of thermal balance to determine the guaranteed gross power. The purpose of the present work is to comment the detail of the validation carried out of the specific thermal balance (thermal kit) of the nuclear power plant, making use of the design characteristics of the different components that conform the vapor cycle. (Author)

  9. Firm Growth Function and Extended-Gibrat’s Property

    Directory of Open Access Journals (Sweden)

    Atushi Ishikawa

    2016-01-01

    Full Text Available We analytically show that the logarithmic average sales of firms first follow power-law growth and subsequently follow exponential growth, if the growth-rate distributions of the sales obey the extended-Gibrat’s property and Gibrat’s law. Here, the extended-Gibrat’s property and Gibrat’s law are statistically observed in short-term data, which denote the dependence of the growth-rate distributions on the initial values. In the derivation, we analytically show that the parameter of the extended-Gibrat’s property is identical to the power-law growth exponent and that it also decides the parameter of the exponential growth. By employing around one million bits of exhaustive sales data of Japanese firms in the ORBIS database, we confirmed our analytic results.

  10. Lidar method to estimate emission rates from extended sources

    Science.gov (United States)

    Currently, point measurements, often combined with models, are the primary means by which atmospheric emission rates are estimated from extended sources. However, these methods often fall short in their spatial and temporal resolution and accuracy. In recent years, lidar has emerged as a suitable to...

  11. Excessive leakage measurement using pressure decay method in containment building local leakage rate test at nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Won Kyu; Kim, Chang Soo; Kim, Wang Bae [KHNP, Central Research Institute, Daejeon (Korea, Republic of)

    2016-06-15

    There are two methods for conducting the containment local leakage rate test (LLRT) in nuclear power plants: the make-up flow rate method and the pressure decay method. The make-up flow rate method is applied first in most power plants. In this method, the leakage rate is measured by checking the flow rate of the make-up flow. However, when it is difficult to maintain the test pressure because of excessive leakage, the pressure decay method can be used as a complementary method, as the leakage rates at pressures lower than normal can be measured using this method. We studied the method of measuring over leakage using the pressure decay method for conducting the LLRT for the containment building at a nuclear power plant. We performed experiments under conditions similar to those during an LLRT conducted on-site. We measured the characteristics of the leakage rate under varies pressure decay conditions, and calculated the compensation ratio based on these data.

  12. Step-Up DC-DC Power Converter

    DEFF Research Database (Denmark)

    2015-01-01

    The present invention relates to a step-up DC-DC power converter which comprises a primary side circuit and a secondary side circuit coupled through a galvanic isolation barrier. The primary side circuit comprises a positive and a negative input terminal for receipt of an input voltage and an input...... being charged from the input voltage and discharged to the output capacitor through the galvanic isolation barrier in accordance with a switch control signal to produce the converter output voltage. The step-up DC-DC power converter comprises an electrical short-circuit connection across the galvanic...

  13. Thermal hydro-dynamic behavior of the nuclear-powered ship Mutsu in the power-up test

    International Nuclear Information System (INIS)

    Ishida, Toshihisa; Kusunoki, Tsuyoshi; Tanaka, Yoshimi; Yao, Toshiaki; Inoue, Kimio; Ochiai, Masa-aki

    1991-01-01

    The first Japanese nuclear ship N.S. Mutsu was tested with heavy load changes as ones of the full scale start-up tests. This paper describes the results of power increasing test, test of crash astern propulsion from ahead cruising, and turbine trip test; In the power increasing test, the main steam flow rate increased from 20 % flow to 70 % flow in 13 seconds; In the test of crash astern propulsion from ahead cruising, an astern turbine maneuvering handle was drawn to the position equivalent to about 60 % reactor power in 30 seconds after an ahead turbine stopping; In the turbine trip test, the ahead turbine was tripped manually at about 100 % power operation. From these tests it was verified that the Mutsu reactor is capable to respond smoothly and safely to the heavy load change without reactor scram, without workings of the pressurizer relief valve and main steam dump valve, and without need of any manual adjustment of the reactor control system. (author)

  14. Near field wireless power transfer using curved relay resonators for extended transfer distance

    International Nuclear Information System (INIS)

    Zhu, D; Beeby, S P; Clare, L; Stark, B H

    2015-01-01

    This paper investigates the performance of a near field wireless power transfer system that uses curved relay resonator to extend transfer distance. Near field wireless power transfer operates based on the near-field electromagnetic coupling of coils. Such a system can transfer energy over a relatively short distance which is of the same order of dimensions of the coupled coils. The energy transfer distance can be increased using flat relay resonators. Recent developments in printing electronics and e-textiles have seen increasing demand of embedding electronics into fabrics. Near field wireless power transfer is one of the most promising methods to power electronics on fabrics. The concept can be applied to body-worn textiles by, for example, integrating a transmitter coil into upholstery, and a flexible receiver coil into garments. Flexible textile coils take on the shape of the supporting materials such as garments, and therefore curved resonator and receiver coils are investigated in this work. Experimental results showed that using curved relay resonator can effectively extend the wireless power transfer distance. However, as the curvature of the coil increases, the performance of the wireless power transfer, especially the maximum received power, deteriorates. (paper)

  15. Direct Power Control for Three-Phase Two-Level Voltage-Source Rectifiers Based on Extended-State Observation

    DEFF Research Database (Denmark)

    Song, Zhanfeng; Tian, Yanjun; Yan, Zhuo

    2016-01-01

    This paper proposed a direct power control strategy for three-phase two-level voltage-source rectifiers based on extended-state observation. Active and reactive powers are directly regulated in the stationary reference frame. Similar to the family of predictive controllers whose inherent characte......This paper proposed a direct power control strategy for three-phase two-level voltage-source rectifiers based on extended-state observation. Active and reactive powers are directly regulated in the stationary reference frame. Similar to the family of predictive controllers whose inherent...

  16. Green-diode-pumped femtosecond Ti:Sapphire laser with up to 450 mW average power.

    Science.gov (United States)

    Gürel, K; Wittwer, V J; Hoffmann, M; Saraceno, C J; Hakobyan, S; Resan, B; Rohrbacher, A; Weingarten, K; Schilt, S; Südmeyer, T

    2015-11-16

    We investigate power-scaling of green-diode-pumped Ti:Sapphire lasers in continuous-wave (CW) and mode-locked operation. In a first configuration with a total pump power of up to 2 W incident onto the crystal, we achieved a CW power of up to 440 mW and self-starting mode-locking with up to 200 mW average power in 68-fs pulses using semiconductor saturable absorber mirror (SESAM) as saturable absorber. In a second configuration with up to 3 W of pump power incident onto the crystal, we achieved up to 650 mW in CW operation and up to 450 mW in 58-fs pulses using Kerr-lens mode-locking (KLM). The shortest pulse duration was 39 fs, which was achieved at 350 mW average power using KLM. The mode-locked laser generates a pulse train at repetition rates around 400 MHz. No complex cooling system is required: neither the SESAM nor the Ti:Sapphire crystal is actively cooled, only air cooling is applied to the pump diodes using a small fan. Because of mass production for laser displays, we expect that prices for green laser diodes will become very favorable in the near future, opening the door for low-cost Ti:Sapphire lasers. This will be highly attractive for potential mass applications such as biomedical imaging and sensing.

  17. Calculation of heat rating and burn-up for test fuel pins irradiated in DR 3

    International Nuclear Information System (INIS)

    Bagger, C.; Carlsen, H.; Hansen, K.

    1980-01-01

    A summary of the DR 3 reactor and HP1 rig design is given followed by a detailed description of the calculation procedure for obtaining linear heat rating and burn-up values of fuel pins irradiated in HP1 rigs. The calculations are carried out rather detailed, especially regarding features like end pellet contribution to power as a function of burn-up, gamma heat contributions, and evaluation of local values of heat rating and burn-up. Included in the report is also a description of the fast flux- and cladding temperature calculation techniques currently used. A good agreement between measured and calculated local burn-up values is found. This gives confidence to the detailed treatment of the data. (author)

  18. An investigation of an uninterruptible power supply (UPS) based on supercapacitor and liquid nitrogen hybridization system

    International Nuclear Information System (INIS)

    Zhang, Xinjing; Xue, Haobai; Xu, Yujie; Chen, Haisheng; Tan, Chunqing

    2014-01-01

    Highlights: • A hybrid UPS based on supercapacitor and liquid nitrogen engine is proposed. • The dynamic modelling of the hybrid UPS system is conducted. • The dynamic working performance is obtained and analysed based on the simulation. • The hybrid UPS enjoys environmental benignity, long life and easy maintenance. • It is a highly possible solution to replace conventional UPS systems. - Abstract: An uninterruptible power supply (UPS) system based on supercapacitor and liquid nitrogen (LN 2 ) hybridization is first introduced in this paper. Of the newly designed UPS, the supercapacitor reacts instantaneously once the main supply fails, and it also starts the LN 2 power system to produce continuing electricity for the customer. This hybrid UPS system is of environment cleanness, long life time, easy maintenaince, etc. A 10 kW model is analyzed in this study. A two-stage nitrogen expander is designed with the rated speed of 900 rpm as the long time power generation device of the LN 2 cycle. The UPS starting process calculation is carried out. The results reveal that commercial supercapacitors could fulfill this request. This UPS could be a competent choice for the UPS application. Further discussion indicates the LN 2 power system could be used widely from UPS to low carbon vehicles

  19. Sea water pumping-up power plant system combined with nuclear power plant

    International Nuclear Information System (INIS)

    Ichiki, Tadaharu; Tanaka, Masayuki.

    1991-01-01

    It is difficult to find a site suitable to construction for a sea water pumping-up power plant at a place relatively near the electric power consumption area. Then, a nuclear power plant is set at the sea bottom or the land portion of a sea shore near the power consumption area. A cavity is excavated underground or at the bottom of the sea in the vicinity of the power plant to form a lower pond, and the bottom of the sea, as an upper pond and the lower pond are connected by a water pressure pipe and a water discharge pipe. A pump water turbine is disposed therebetween, to which electric power generator is connected. In addition, an ordinary or emergency cooling facility in the nuclear power plant is constituted such that sea water in the cavity is supplied by a sea water pump. Accordingly, the sea water pumping-up plant system in combination with the nuclear power plant is constituted with no injuring from salts to animals and plants on land in the suburbs of a large city. The cost for facilities for supplying power from a remote power plant to large city areas and power loss are decreased and stable electric power can be supplied. (N.H.)

  20. PowerPal: power up your creek

    International Nuclear Information System (INIS)

    2006-01-01

    PowerPal micro-hydro equipment was developed in Vietnam by Asian Phoenix Resources Ltd. of Victoria, BC; a company who aims to help disadvantaged people in less developed countries by making renewable energy devices available to them. The idea for the micro-hydro system was conceived after mineral exploration parties in Vietnam noted that large numbers of poor quality propeller turbines were being used to supply AC power to individual homes. A plan was developed to improve the quality and reliability of low head turbines with better castings, magnets, superior bearings and electronic load controllers. Funding for the program was initially difficult to obtain. However, PowerPal micro-hydro equipment eventually came to the attention of the World Bank as well as other government and non-governmental organizations. Financing for the purchase and installation of larger numbers of units has now been achieved, and missionary groups in various parts of the world have ordered units. European markets have also opened up, and distributors of the micro-hydro equipment have been appointed in various countries. Sales are now strong in Central America, South America, the Caribbean, Australasia, Oceania, Africa and Europe. It was concluded that the surge of interest has coincided with a steep upturn in oil prices. 8 figs

  1. University Knowledge Spillovers & Regional Start-up Rates

    DEFF Research Database (Denmark)

    Hellerstedt, Karin; Wennberg, Karl; Frederiksen, Lars

    2014-01-01

    how characteristics of the economic and political milieu within each region influence the ratio of firm births. We find that knowledge spillovers from universities and firm-based R&D strongly affect the start-up rates for both high-tech firms and knowledge-intensive services firms. Further, the start......This chapter investigates how regional start-up rates in the knowledge-intensive services and high-tech industries are influenced by knowledge spillovers from both universities and firm-based R&D activities. Integrating insights from economic geography and organizational ecology into the literature......-up rate of knowledge-intensive service firms is tied more strongly to the supply of university educated individuals and the political regulatory regime within the municipality than start-ups in high-tech industries. This suggests that knowledge-intensive service-start-ups are more susceptible to both...

  2. 76 FR 48159 - Integrated System Power Rates

    Science.gov (United States)

    2011-08-08

    ... DEPARTMENT OF ENERGY Southwestern Power Administration Integrated System Power Rates AGENCY... American Electric Reliability Corporation and to cover increased investments and replacements in..., prepared a Current Power Repayment Study using existing system rates. The Study indicates that Southwestern...

  3. Rise-to-power test in High Temperature Engineering Test Reactor. Test progress and summary of test results up to 30 MW of reactor thermal power

    International Nuclear Information System (INIS)

    Nakagawa, Shigeaki; Fujimoto, Nozomu; Shimakawa, Satoshi

    2002-08-01

    The High Temperature Engineering Test Reactor (HTTR) is a graphite moderated and gas cooled reactor with the thermal power of 30 MW and the reactor outlet coolant temperature of 850degC/950degC. Rise-to-power test in the HTTR was performed from April 23rd to June 6th in 2000 as phase 1 test up to 10 MW in the rated operation mode, from January 29th to March 1st in 2001 as phase 2 test up to 20 MW in the rated operation mode and from April 14th to June 8th in 2001 as phase 3 test up to 20 MW in the high temperature test the mechanism of the reactor outlet coolant temperature becomes 850degC at 30 MW in the rated operation mode and 950degC in the high temperature test operation mode. Phase 4 rise-to-power test to achieve the thermal reactor power of 30 MW started on October 23rd in 2001. On December 7th in 2001 it was confirmed that the thermal reactor power and the reactor outlet coolant temperature reached to 30 MW and 850degC respectively in the single loaded operation mode in which only the primary pressurized water cooler is operating. Phase 4 test was performed until March 6th in 2002. JAERI (Japan Atomic Energy Research Institute) obtained the certificate of the pre-operation test from MEXT (Ministry of Education Culture Sports Science and Technology) after all the pre-operation tests by MEXT were passed successfully with the reactor transient test at an abnormal event as a final pre-operation test. From the test results of the rise-up-power test up to 30 MW in the rated operation mode, performance of the reactor and cooling system were confirmed, and it was also confirmed that an operation of reactor facility can be performed safely. Some problems to be solved were found through the tests. By solving them, the reactor operation with the reactor outlet coolant temperature of 950degC will be achievable. (author)

  4. Suitability of representative electrochemical energy storage technologies for ramp-rate control of photovoltaic power

    Science.gov (United States)

    Jiang, Yu; Fletcher, John; Burr, Patrick; Hall, Charles; Zheng, Bowen; Wang, Da-Wei; Ouyang, Zi; Lennon, Alison

    2018-04-01

    Photovoltaic (PV) systems can exhibit rapid variances in their power output due to irradiance changes which can destabilise an electricity grid. This paper presents a quantitative comparison of the suitability of different electrochemical energy storage system (ESS) technologies to provide ramp-rate control of power in PV systems. Our investigations show that, for PV systems ranging from residential rooftop systems to megawatt power systems, lithium-ion batteries with high energy densities (up to 600 Wh L-1) require the smallest power-normalised volumes to achieve the ramp rate limit of 10% min-1 with 100% compliance. As the system size increases, the ESS power-normalised volume requirements are significantly reduced due to aggregated power smoothing, with high power lithium-ion batteries becoming increasingly more favourable with increased PV system size. The possibility of module-level ramp-rate control is also introduced, and results show that achievement of a ramp rate of 10% min-1 with 100% compliance with typical junction box sizes will require ESS energy and power densities of 400 Wh L-1 and 2300 W L-1, respectively. While module-level ramp-rate control can reduce the impact of solar intermittence, the requirement is challenging, especially given the need for low cost and long cycle life.

  5. Unit availability not affected by extending outage cycles

    Energy Technology Data Exchange (ETDEWEB)

    Smith, D.J.

    2003-03-01

    To improve their economic dispatch position, more and more plant owners are extending the intervals between major outages for boilers from one year to 18-24 months and for steam turbine up to 12 years. In many instances, extended outage cycles have resulted in no loss in availability or increases in forced outages. The article discusses outage scheduling at Tucson Electric Power's Springville coal-fired plant, the Panther Creek Energy Facility in Pennsylvania, and at Tennessee Valley Authority's coal-fired power plants. 1 fig.

  6. Developing a virtual reality application for training Nuclear Power Plant operators: Setting up a database containing dose rates in the refuelling plant

    International Nuclear Information System (INIS)

    Rodenas, J.; Zarza, I.; Burgos, M. C.; Felipe, A.; Sanchez-Mayoral, M. L.

    2004-01-01

    Operators in Nuclear Power Plants can receive high doses during refuelling operations. A training programme for simulating refuelling operations will be useful in reducing the doses received by workers as well as minimising operation time. With this goal in mind, a virtual reality application is developed within the framework of the CIPRES project. The application requires doses, both instantaneous and accumulated, to be displayed at all times during operator training. Therefore, it is necessary to set up a database containing dose rates at every point in the refuelling plant. This database is based on radiological protection surveillance data measured in the plant during refuelling operations. Some interpolation routines have been used to estimate doses through the refuelling plant. Different assumptions have been adopted in order to perform the interpolation and obtain consistent data. In this paper, the procedures developed to set up the dose database for the virtual reality application are presented and analysed. (authors)

  7. Impact of steam generator start-up limitations on the performance of a parabolic trough solar power plant

    DEFF Research Database (Denmark)

    Ferruzza, Davide; Topel, Monika; Laumert, Björn

    2018-01-01

    typically start-up and shut down every day, so in order to maximize their profitability, it is necessary to increase their flexibility in transient operation and to initiate power generation as rapidly as possible. Two of the key components are the steam generator and steam turbine and the rates at which...... they can reach operational speed are limited by thermo-mechanical constraints. This paper presents an analysis of the effects of the thermal stress limitations of the steam generator and steam turbine on the power plant start-up, and quantifies their impact on the economy of the system. A dynamic model......-driven and peak-load. The results indicate that for steam generator hot start-ups, a 1.5% increase in peak-load electricity production would be achieved by doubling the maximum allowable heating rate of the evaporator. No useful increase would be achieved by increasing the rates beyond a limit of 7–8 K...

  8. Modeling of WWER-440 Fuel Pin Behavior at Extended Burn-up

    International Nuclear Information System (INIS)

    El-Koliel, M.S.; Abou-Zaid, A.A.; El-Kafas, A.A.

    2004-01-01

    Currently, there is an ongoing effort to increase fuel discharge burn-up of all LWRs fuel including WWER's as much as possible in order to decrease power production cost. Therefore, burn-up is expected to be increased to 60 to 70 Mwd/kg U. The change in the fuel radial power distribution as a function of fuel burn up can affect the radial fuel temperature distribution as well as the fuel microstructure in the fuel pellet rim. In this paper, the radial burn-up and fissile products distributions of WWER-440 UO 2 fuel pin were evaluated using MCNP 4B and ORIGEN2 codes. The impact of the thermal conductivity on predicted fission gas release calculations is needed. For the analysis, a typical WWER-440 fuel pin and surrounding water moderator are considered in a hexagonal pin cell well. The thermal release and the athermal release from the pellet rim were modeled separately. The fraction of the rim structure and the excessive porosity in the rim structure in isothermal irradiation as a function of the fuel burn-up was predicted. a computer program; RIMSC-01, is developed to perform the required FGR calculations. Finally, the relevant phenomena and the corresponding models together with their validation are presented

  9. 77 FR 67813 - Sam Rayburn Dam Project Power Rate

    Science.gov (United States)

    2012-11-14

    ... DEPARTMENT OF ENERGY Southwestern Power Administration Sam Rayburn Dam Project Power Rate AGENCY: Southwestern Power Administration, DOE. ACTION: Notice of Rate Order Approving an Extension of Power Rate on an.... James K. McDonald, Assistant Administrator, Southwestern Power Administration, Department of Energy...

  10. Power start up of the Dalat nuclear research reactor

    International Nuclear Information System (INIS)

    Pham Duy Hien; Ngo Quang Huy; Vu Hai Long; Tran Khanh Mai

    1994-01-01

    After accomplishing the physical start-up of the reactor, the power start-up was carried out in February 1984. The power of the reactor has reached: 10 KW on 6/2/1984, 100 KW on 7/2/1984, 200 KW and 300 KW on 8/2/1984; 400 KW and nominal power 500 KW on 9/2/1984. The reactivity temperature coefficient and the xenon poisoning were determined. 3 figs., 12 tabs

  11. Hysteroscopic Essure Inserts for Permanent Contraception: Extended Follow-Up Results of a Phase III Multicenter International Study.

    Science.gov (United States)

    Chudnoff, Scott G; Nichols, John E; Levie, Mark

    2015-01-01

    To describe safety, tolerability, and effectiveness results through 5 years of follow-up of a Phase III trial with Essure inserts. Multicenter, nonrandomized, single-arm international study (Canadian Task Force classification II-3). Thirteen clinical study centers in the United States, Europe, and Australia. A total of 518 previously fertile women seeking permanent contraception. The objective of the hysteroscopic sterilization procedure was bilateral Essure insert placement (ESS205 model) and tubal occlusion. Women with satisfactory device location and tube occlusion (based on modified hysterosalpingography [HSG]) were instructed to discontinue alternative contraception and to rely on Essure inserts for permanent contraception. The primary endpoint for the Phase III study was the rate of pregnancies occurring during the first year of relying (i.e., HSG-confirmed occlusion) on the Essure inserts for permanent contraception (i.e., 12 months after HSG). For the full 5 years of follow-up (5 years total of relying on the Essure inserts for contraception), the endpoints of interest were safety, prevention of pregnancy, and satisfaction. No pregnancies were reported among women relying on the Essure inserts who completed the full 5 years of follow-up. As of December 5, 2007, 449 women with successful bilateral placement relying on the Essure inserts contributed a total 24 942 woman-months of follow-up for assessing effectiveness. Overall, the Essure inserts were generally well tolerated, with participant comfort rated as "good" to "excellent" by 99% of women (382 of 385) after 5 years of use. Similarly, overall satisfaction was rated as "somewhat" to "very satisfied" by 98% of women (376 of 384) after 5 years of use. The majority of adverse events reported during the 5 years of follow-up were rated as either "mild" or "moderate" in severity. Three severe events (abdominal pain with very heavy periods and irregular menstrual bleeding) were reported in 2 subjects during

  12. [Voluntary alpha-power increasing training impact on the heart rate variability].

    Science.gov (United States)

    Bazanova, O M; Balioz, N V; Muravleva, K B; Skoraia, M V

    2013-01-01

    In order to study the effect of the alpha EEG power increasing training at heart rate variability (HRV) as the index of the autonomic regulation of cognitive functions there were follow tasks: (1) to figure out the impact of biofeedback in the voluntary increasing the power in the individual high-frequency alpha-band effect on heart rate variability and related characteristics of cognitive and emotional spheres, (2) to determine the nature of the relationship between alpha activity indices and heart rate variability, depending on the alpha-frequency EEG pattern at rest (3) to examine how the individual alpha frequency EEG pattern is reflected in changes HRV as a result of biofeedback training. Psychometric indicators of cognitive performance, the characteristics of the alpha-EEG activity and heart rate variability (HRV) as LF/HF and pNN50 were recorded in 27 healthy men aged 18-34 years, before, during, and after 10 sessions of training of voluntary increase in alpha power in the individual high-frequency alpha band with eyes closed. To determine the biofeedback effect on the alpha power increasing training, data subjects are compared in 2 groups: experimental (14) with the real and the control group (13 people)--with mock biofeedback. The follow up effect of trainings was studied through month over the 10 training sessions. Results showed that alpha biofeedback training enhanced the fluency and accuracy in cognitive performance, decreased anxiety and frontal EMG, increased resting frequency, width and power in individual upper alpha range only in participants with low baseline alpha frequency. While mock biofeedback increased resting alpha power only in participants with high baseline resting alpha frequency and did change neither cognitive performance, nor HRV indices. Biofeedback training eliminated the alpha power decrease in response to arithmetic task in both with high and low alpha frequency participants and this effect was followed up over the month. Mock

  13. Preparation and scale up of extended-release tablets of bromopride

    Directory of Open Access Journals (Sweden)

    Guilherme Neves Ferreira

    2014-04-01

    Full Text Available Reproducibility of the tablet manufacturing process and control of its pharmaceutics properties depends on the optimization of formulation aspects and process parameters. Computer simulation such as Design of Experiments (DOE can be used to scale up the production of this formulation, in particular for obtaining sustained-release tablets. Bromopride formulations are marketed in the form of extended-release pellets, which makes the product more expensive and difficult to manufacture. The aim of this study was to formulate new bromopride sustained release formulations as tablets, and to develop mathematical models to standardize the scale up of this formulation, controlling weight and hardness of the tablets during manufacture according to the USP 34th edition. DOE studies were conducted using Minitab(tm software. Different excipient combinations were evaluated in order to produce bromopride sustained-release matrix tablets. In the scale-up study, data were collected and variations in tableting machine parameters were measured. Data were processed by Minitab(tm software, generating mathematical equations used for prediction of powder compaction behavior, according to the settings of the tableting machine suitable for scale-up purposes. Bromopride matrix tablets with appropriate characteristics for sustained release were developed. The scale-up of the formulation with the most suitable sustained release profile was established by using mathematical models, indicating that the formulation can be a substitute for the pellets currently marketed.

  14. An Efficiency-Optimized Isolated Bidirectional DC-DC Converter with Extended Power Range for Energy Storage Systems in Microgrids

    Directory of Open Access Journals (Sweden)

    Xiaolong Shi

    2012-12-01

    Full Text Available This paper proposes a novel extended-single-phase shift (ESPS control strategy of isolated bidirectional full-bridge DC-DC converters (IBDCs which are a promising alternative as a power electronic interface in microgrids with an additional function of galvanic isolation. Based on the mathematical models of ESPS control under steady-state conditions, detailed theoretical and experimental analyses of IBDC under ESPS control are presented. Compared with conventional single-phase-shift (CSPS control, ESPS control can greatly improve the efficiency of IBDCs in microgrids through decreasing current stress and backflow power considerably over a wide input and output voltage range under light and medium loads. In addition, ESPS control only needs to adjust one single phase-shift angel to control transmission power, thus it retains implementation simplicity in comparison with dual-phase-shift (DPS control for microgrid applications. Furthermore, an efficiency-optimized modulation scheme based on ESPS and CSPS control is developed in the whole power range of IBDC for power distribution in microgrids. A 10 kW IBDC prototype is constructed and the experimental results validate the effectiveness of the proposed control strategy, showing that the proposed strategy can enhance the overall efficiency up to 30%.

  15. Procedure of determination of the nuclear reactor start-up power

    International Nuclear Information System (INIS)

    Brandt, K.D.; Griese, K.; Guehne, F.

    1985-01-01

    The invention has been aimed at a determination of the thermal reactor power during the start-up period and the commissioning resp. preferably under an extremely low thermal power in a range from 0.001 to 1%. In addition to it also the power range up to 100% shall be covered. The external gamma-ray flux density as a function of the thermal reactor power is measured in several overlapping partial measuring ranges. A suitable measuring device transforms the input signals into an electrically measured quantity proportional to the reactor power

  16. HEPS4Power - Extended-range Hydrometeorological Ensemble Predictions for Improved Hydropower Operations and Revenues

    Science.gov (United States)

    Bogner, Konrad; Monhart, Samuel; Liniger, Mark; Spririg, Christoph; Jordan, Fred; Zappa, Massimiliano

    2015-04-01

    In recent years large progresses have been achieved in the operational prediction of floods and hydrological drought with up to ten days lead time. Both the public and the private sectors are currently using probabilistic runoff forecast in order to monitoring water resources and take actions when critical conditions are to be expected. The use of extended-range predictions with lead times exceeding 10 days is not yet established. The hydropower sector in particular might have large benefits from using hydro meteorological forecasts for the next 15 to 60 days in order to optimize the operations and the revenues from their watersheds, dams, captions, turbines and pumps. The new Swiss Competence Centers in Energy Research (SCCER) targets at boosting research related to energy issues in Switzerland. The objective of HEPS4POWER is to demonstrate that operational extended-range hydro meteorological forecasts have the potential to become very valuable tools for fine tuning the production of energy from hydropower systems. The project team covers a specific system-oriented value chain starting from the collection and forecast of meteorological data (MeteoSwiss), leading to the operational application of state-of-the-art hydrological models (WSL) and terminating with the experience in data presentation and power production forecasts for end-users (e-dric.ch). The first task of the HEPS4POWER will be the downscaling and post-processing of ensemble extended-range meteorological forecasts (EPS). The goal is to provide well-tailored forecasts of probabilistic nature that should be reliable in statistical and localized at catchment or even station level. The hydrology related task will consist in feeding the post-processed meteorological forecasts into a HEPS using a multi-model approach by implementing models with different complexity. Also in the case of the hydrological ensemble predictions, post-processing techniques need to be tested in order to improve the quality of the

  17. Understanding deposition rate loss in high power impulse magnetron sputtering: I. Ionization-driven electric fields

    International Nuclear Information System (INIS)

    Brenning, N; Huo, C; Raadu, M A; Lundin, D; Helmersson, U; Vitelaru, C; Stancu, G D; Minea, T

    2012-01-01

    The lower deposition rate for high power impulse magnetron sputtering (HiPIMS) compared with direct current magnetron sputtering for the same average power is often reported as a drawback. The often invoked reason is back-attraction of ionized sputtered material to the target due to a substantial negative potential profile, sometimes called an extended presheath, from the location of ionization toward the cathode. Recent studies in HiPIMS devices, using floating-emitting and swept-Langmuir probes, show that such extended potential profiles do exist, and that the electric fields E z directed toward the target can be strong enough to seriously reduce ion transport to the substrate. However, they also show that the potential drops involved can vary by up to an order of magnitude from case to case. There is a clear need to understand the underlying mechanisms and identify the key discharge variables that can be used for minimizing the back-attraction. We here present a combined theoretical and experimental analysis of the problem of electric fields E z in the ionization region part of HiPIMS discharges, and their effect on the transport of ionized sputtered material. In particular, we have investigated the possibility of a ‘sweet spot’ in parameter space in which the back-attraction of ionized sputtered material is low. It is concluded that a sweet spot might possibly exist for some carefully optimized discharges, but probably in a rather narrow window of parameters. As a measure of how far a discharge is from such a window, a Townsend product Π Townsend is proposed. A parametric analysis of Π Townsend shows that the search for a sweet spot is complicated by the fact that contradictory demands appear for several of the externally controllable parameters such as high/low working gas pressure, short/long pulse length, high/low pulse power and high/low magnetic field strength. (paper)

  18. Improved estimates of external gamma dose rates in the environs of Hinkley Point Power Station

    International Nuclear Information System (INIS)

    Macdonald, H.F.; Thompson, I.M.G.

    1988-07-01

    The dominant source of external gamma dose rates at centres of population within a few kilometres of Hinkley Point Power Station is the routine discharge of 41-Ar from the 'A' station magnox reactors. Earlier estimates of the 41-Ar radiation dose rates were based upon measured discharge rates, combined with calculations using standard plume dispersion and cloud-gamma integration models. This report presents improved dose estimates derived from environmental gamma dose rate measurements made at distances up to about 1 km from the site, thus minimising the degree of extrapolation introduced in estimating dose rates at locations up to a few kilometres from the site. In addition, results from associated chemical tracer measurements and wind tunnel simulations covering distances up to about 4 km from the station are outlined. These provide information on the spatial distribution of the 41-Ar plume during the initial stages of its dispersion, including effects due to plume buoyancy and momentum and behaviour under light wind conditions. In addition to supporting the methodology used for the 41-Ar dose calculations, this information is also of generic interest in the treatment of a range of operational and accidental releases from nuclear power station sites and will assist in the development and validation of existing environmental models. (author)

  19. Sensitivity Analysis of Core Damage from Reactor Coolant Pump Seal Leakage during Extended Loss of All AC Power

    Energy Technology Data Exchange (ETDEWEB)

    Park, Da Hee; Kim, Min Gi; Lee, Kyung Jin; Hwang, Su hyun; Lee, Byung Chul [FNC Technology Co. Ltd., Yongin (Korea, Republic of); Yoon, Duk Joo; Lee, Seung Chan [Korea Hydro and Nuclear Power Co. Ltd., Daejeon (Korea, Republic of)

    2015-10-15

    In this study, in order to comprehend the Fukushima accident, the sensitivity analysis was performed to analyze the behavior of Reactor Coolant System (RCS) during ELAP using the RELAP5/MOD3.3 code. The Fukushima accident was caused by tsunami resulted in Station Black Out (SBO) followed by the reactor core melt-down and release of radioactive materials. After the accident, the equipment and strategies for the Extended Loss of All AC Power (ELAP) were recommended strongly. In this analysis, sensitivity studies for the RCP seal failure of the OPR1000 type NPP were performed by using RELAP5/MOD3.3 code. Six cases with different leakage rate of RCP seal were studied for ELAP with operator action or not. The main findings are summarized as follows: (1) Without the operator action, the core uncovery time is determined by the leakage rate of RCP seal. When the leakage rate per RCP seal are 5 gpm, 50 gpm, and 300 gpm respectively, the core uncovery time are 1.62 hr, 1.58 hr, and 1.29 hr respectively. Namely, If the leakage rate of RCP seal was much bigger, the uncover time of core would be shorter. (2) In case that the cooling by SG secondary side was performed using the TDAFP and SG ADV, the core uncovery time was significantly extended.

  20. Wheeling rates evaluation using optimal power flows

    International Nuclear Information System (INIS)

    Muchayi, M.; El-Hawary, M. E.

    1998-01-01

    Wheeling is the transmission of electrical power and reactive power from a seller to a buyer through a transmission network owned by a third party. The wheeling rates are then the prices charged by the third party for the use of its network. This paper proposes and evaluates a strategy for pricing wheeling power using a pricing algorithm that in addition to the fuel cost for generation incorporates the optimal allocation of the transmission system operating cost, based on time-of-use pricing. The algorithm is implemented for the IEEE standard 14 and 30 bus system which involves solving a modified optimal power flow problem iteratively. The base of the proposed algorithm is the hourly spot price. The analysis spans a total time period of 24 hours. Unlike other algorithms that use DC models, the proposed model captures wheeling rates of both real and reactive power. Based on the evaluation, it was concluded that the model has the potential for wide application in calculating wheeling rates in a deregulated competitive power transmission environment. 9 refs., 3 tabs

  1. Design criteria for an uninterruptable power source (UPS)

    Energy Technology Data Exchange (ETDEWEB)

    Okeke, S.S.N. [Nnamdi Azikiwe Univ. Awka (Nigeria). Dept. of Science Technology; Okeke, C.A. [Nnamdi Azikiwe Univ. Awka (Nigeria). Dept. of Science Technology; Mortune, B.U. [Nnamdi Azikiwe Univ. Awka (Nigeria). Dept. of Science Technology; Okeke, C.C. [Univ. of Nigeria, Nsukka (Nigeria). Dept. of Computer Science

    1997-05-01

    This paper on uninterruptible power source (UPS) is a result of an R and D project; it describes the components of a UPS system and reviews the design requirements necessary for its construction with low cost and ease of maintenance. (orig.)

  2. Water Chemistry Control Technology to Improve the Performance of Nuclear Power Plants for Extended Fuel Cycles

    International Nuclear Information System (INIS)

    Maeng, W. Y.; Na, J. W.; Lee, E. H.

    2010-07-01

    Ο To Develop the technology to manage the problems of AOA and radiation, corrosion as long term PWR operation. Ο To Establish the advanced water chemical operating systems. - Development of the proper water chemistry guidelines for long term PWR operation. AOA(Axial Offest Anomaly) has been reported in many PWR plants in the world, including Korea, especially in the plants of higher burn-up and longer cycle operation or power up-rate. A test loop has been designed and made by KAERI, in order to investigate and mitigate AOA problems in Korea. This project included the study of hydrodynamic simulation and the modeling about AOA. The analysis of radioactive crud was performed to investigate of NPPs primary water chemical effect on AOA and to reduce the radioactive dose rate. The high temperature measurement system was developed to on-line monitor of water chemistry in nuclear power plants. The effects of various environmental factors such as temperature, pressure, and flow rate on YSZ-based pH electrode were evaluated for ensuring the accuracy of high-temperature pH measurement. The inhibition technology for fouling and SCC of SG tube was evaluated to establish the water chemistry technology of corrosion control of nuclear system. The high temperature and high pressure crevice chemistry analysis test loop was manufactured to develop the water chemistry technology of crevice chemistry control

  3. Higher Magnitude Cash Payments Improve Research Follow-up Rates Without Increasing Drug Use or Perceived Coercion

    Science.gov (United States)

    Festinger, David S.; Marlowe, Douglas B.; Dugosh, Karen L.; Croft, Jason R.; Arabia, Patricia L.

    2008-01-01

    In a prior study (Festinger et al., 2005) we found that neither the mode (cash vs. gift card) nor magnitude ($10, $40, or $70) of research follow-up payments increased rates of new drug use or perceptions of coercion. However, higher payments and payments in cash were associated with better follow-up attendance, reduced tracking efforts, and improved participant satisfaction with the study. The present study extended those findings to higher payment magnitudes. Participants from an urban outpatient substance abuse treatment program were randomly assigned to receive $70, $100, $130, or $160 in either cash or a gift card for completing a follow-up assessment at 6 months post-admission (n ≅ 50 per cell). Apart from the payment incentives, all participants received a standardized, minimal platform of follow-up efforts. Findings revealed that neither the magnitude nor mode of payment had a significant effect on new drug use or perceived coercion. Consistent with our previous findings, higher payments and cash payments resulted in significantly higher follow-up rates and fewer tracking calls. In addition participants receiving cash vs. gift cards were more likely to use their payments for essential, non-luxury purchases. Follow-up rates for participants receiving cash payments of $100, $130, and $160 approached or exceeded the FDA required minimum of 70% for studies to be considered in evaluations of new medications. This suggests that the use of higher magnitude payments and cash payments may be effective strategies for obtaining more representative follow-up samples without increasing new drug use or perceptions of coercion. PMID:18395365

  4. A highly sensitive RF-to-DC power converter with an extended dynamic range

    KAUST Repository

    Almansouri, Abdullah Saud Mohammed; Ouda, Mahmoud H.; Salama, Khaled N.

    2017-01-01

    This paper proposes a highly sensitive RF-to-DC power converter with an extended dynamic range that is designed to operate at the medical band 433 MHz and simulated using 0.18 μm CMOS technology. Compared to the conventional fully cross

  5. New methods for estimating follow-up rates in cohort studies

    Directory of Open Access Journals (Sweden)

    Xiaonan Xue

    2017-12-01

    Full Text Available Abstract Background The follow-up rate, a standard index of the completeness of follow-up, is important for assessing the validity of a cohort study. A common method for estimating the follow-up rate, the “Percentage Method”, defined as the fraction of all enrollees who developed the event of interest or had complete follow-up, can severely underestimate the degree of follow-up. Alternatively, the median follow-up time does not indicate the completeness of follow-up, and the reverse Kaplan-Meier based method and Clark’s Completeness Index (CCI also have limitations. Methods We propose a new definition for the follow-up rate, the Person-Time Follow-up Rate (PTFR, which is the observed person-time divided by total person-time assuming no dropouts. The PTFR cannot be calculated directly since the event times for dropouts are not observed. Therefore, two estimation methods are proposed: a formal person-time method (FPT in which the expected total follow-up time is calculated using the event rate estimated from the observed data, and a simplified person-time method (SPT that avoids estimation of the event rate by assigning full follow-up time to all events. Simulations were conducted to measure the accuracy of each method, and each method was applied to a prostate cancer recurrence study dataset. Results Simulation results showed that the FPT has the highest accuracy overall. In most situations, the computationally simpler SPT and CCI methods are only slightly biased. When applied to a retrospective cohort study of cancer recurrence, the FPT, CCI and SPT showed substantially greater 5-year follow-up than the Percentage Method (92%, 92% and 93% vs 68%. Conclusions The Person-time methods correct a systematic error in the standard Percentage Method for calculating follow-up rates. The easy to use SPT and CCI methods can be used in tandem to obtain an accurate and tight interval for PTFR. However, the FPT is recommended when event rates and

  6. Effect of External Loading on Force and Power Production During Plyometric Push-ups.

    Science.gov (United States)

    Hinshaw, Taylour J; Stephenson, Mitchell L; Sha, Zhanxin; Dai, Boyi

    2018-04-01

    Hinshaw, TJ, Stephenson, ML, Sha, Z, and Dai, B. Effect of external loading on force and power production during plyometric push-ups. J Strength Cond Res 32(4): 1099-1108, 2018-One common exercise to train upper-body strength and power is the push-up. Training at the loads that would produce the greatest power is an effective way to increase peak power. The purpose of the current study was to quantify the changes in peak force, peak power, and peak velocity among a modified plyometric push-up and plyometric push-ups with or without external loading in physically active young adults. Eighteen male and 17 female participants completed 4 push-ups: (a) modified plyometric push-up on the knees, (b) plyometric push-up without external loading, (c) plyometric push-up with an external load of 5% of body weight, and (d) plyometric push-up with an external load of 10% of body weight. Two force platforms were set up to collect vertical ground reaction forces at the hands and feet. The modified plyometric push-up demonstrated the lowest force, power, and velocity (5.4≥ Cohen's dz ≥1.2). Peak force and force at peak velocity increased (3.8≥ Cohen's dz ≥0.3) and peak velocity and velocity at peak power decreased (1.4≥ Cohen's dz ≥0.8) for the push-up without external loading compared with the 2 push-ups with external loading. No significant differences were observed for peak power among the push-ups with or without external loading (0.4≥ Cohen's dz ≥0.1). Although peak power is similar with or without external loading, push-ups without external loading may be more beneficial for a quick movement, and push-ups with external loading may be more beneficial for a greater force production.

  7. Evaluation of high step-up power electronics stages in thermoelectric generator systems

    DEFF Research Database (Denmark)

    Sun, Kai; Ni, Longxian; Chen, Min

    2013-01-01

    To develop practical thermoelectric generator (TEG) systems, especially radioisotope thermoelectric power supplies for deep-space exploration, a power conditioning stage with high step-up gain is indispensable. This stage is used to step up the low output voltage of thermoelectric generators...... to the required high level. Furthermore, maximum power point tracking control for TEG modules needs to be implemented into the power electronics stages. In this paper, the temperature-dependent electrical characteristics of a thermoelectric generator are analyzed in depth. Three typical high step-up power...... converters suitable for TEG applications are discussed: an interleaved boost converter, a boost converter with a coupled inductor and an interleaved boost converter with an auxiliary transformer. A general comparison of the three high step-up converters is conducted to study the step-up gain, conversion...

  8. Nuclear power's effects on electric rate making

    International Nuclear Information System (INIS)

    Smith, D.S.; Lancaster, A.A.

    1978-01-01

    Government and the electric utility industry are re-evaluating nuclear power's contribution to the total U.S. energy supplies. This article addresses how the recently increased nuclear plant construction and operation costs are translated into the prices that consumers pay for electricity. The electric rates that consumers pay must reflect the costs of producing electricity, as well as the costs of transmission, distribution, metering, and billing. The use of nuclear power for electric production is anticipated to grow rapidly so as to meet a larger portion of our country's electricity needs through the end of the century; so nuclear power costs are expected to be an even larger portion of the total electricity price. There are certain rate-making issues that are actively being discussed in public forums and before state and Federal regulatory bodies. These issues are not unique to nuclear power, but take on added significance when nuclear power is used by utilities to produce electricity because of the technology required and because of the type, timing, and magnitude of the costs involved. These are: (1) inclusion of construction work in progress in the rate base; (2) fuel adjustment clauses and treatment of nuclear fuel cycle costs; (3) treatment of certain taxes under the rate-making method called normalization or deferral accounting (sometimes referred to as ''phantom taxes''); and (4) rate treatment for particular nuclear expense items reflecting costs of delays, plant cancellations, and operational slowdowns

  9. 53 W average power few-cycle fiber laser system generating soft x rays up to the water window.

    Science.gov (United States)

    Rothhardt, Jan; Hädrich, Steffen; Klenke, Arno; Demmler, Stefan; Hoffmann, Armin; Gotschall, Thomas; Eidam, Tino; Krebs, Manuel; Limpert, Jens; Tünnermann, Andreas

    2014-09-01

    We report on a few-cycle laser system delivering sub-8-fs pulses with 353 μJ pulse energy and 25 GW of peak power at up to 150 kHz repetition rate. The corresponding average output power is as high as 53 W, which represents the highest average power obtained from any few-cycle laser architecture so far. The combination of both high average and high peak power provides unique opportunities for applications. We demonstrate high harmonic generation up to the water window and record-high photon flux in the soft x-ray spectral region. This tabletop source of high-photon flux soft x rays will, for example, enable coherent diffractive imaging with sub-10-nm resolution in the near future.

  10. Online condition monitoring to enable extended operation of nuclear power plants

    International Nuclear Information System (INIS)

    Meyer, Ryan Michael; Bond, Leonard John; Ramuhalli, Pradeep

    2012-01-01

    Safe, secure, and economic operation of nuclear power plants will remain of strategic significance. New and improved monitoring will likely have increased significance in the post-Fukushima world. Prior to Fukushima, many activities were already underway globally to facilitate operation of nuclear power plants beyond their initial licensing periods. Decisions to shut down a nuclear power plant are mostly driven by economic considerations. Online condition monitoring is a means to improve both the safety and economics of extending the operating lifetimes of nuclear power plants, enabling adoption of proactive aging management. With regard to active components (e.g., pumps, valves, motors, etc.), significant experience in other industries has been leveraged to build the science base to support adoption of online condition-based maintenance and proactive aging management in the nuclear industry. Many of the research needs are associated with enabling proactive management of aging in passive components (e.g., pipes, vessels, cables, containment structures, etc.). This paper provides an overview of online condition monitoring for the nuclear power industry with an emphasis on passive components. Following the overview, several technology/knowledge gaps are identified, which require addressing to facilitate widespread online condition monitoring of passive components. (author)

  11. Cost-related model for transit rates in electric power distribution networks

    International Nuclear Information System (INIS)

    Collstrand, F.

    1994-02-01

    The planned deregulation of the swedish electrical power market will require a new structure of the electrical energy rates. In this report different models of transit rates are studied. The report includes studies of literature and a proposal to a rate structure and is made specifically for Malmoe Energi AB. The differences between various methods of calculating the transfer cost are illustrated. Further, the build-up of the tariff structure and its base elements are discussed. The costs are divided on different categories of costumers and shows the cost for each customer. The new regulations should apply simultaneously to all networks, independent of the voltage level. The transit cost should be based on a number of basic elements: capital cost, operation and maintenance, losses, measuring and administration. Capital cost and operation and maintenance should be charged as power fees, the loss cost as an energy fee and the measuring and administration cost as a fixed fee. The customer bill should be split into two parts, one for the transit cost and one for the energy usage. 15 refs., 37 tabs., 6 figs

  12. A highly sensitive RF-to-DC power converter with an extended dynamic range

    KAUST Repository

    Almansouri, Abdullah Saud Mohammed

    2017-10-24

    This paper proposes a highly sensitive RF-to-DC power converter with an extended dynamic range that is designed to operate at the medical band 433 MHz and simulated using 0.18 μm CMOS technology. Compared to the conventional fully cross-coupled rectifier, the proposed design offers 3.2× the dynamic range. It is also highly sensitive and requires −18 dBm of input power to produce a 1 V-output voltage when operating with a 100 kΩ load. Furthermore, the proposed design offers an open circuit sensitivity of −23.4 dBm and a peak power conversion efficiency of 67%.

  13. The impact of alcohol hand sanitizer use on infection rates in an extended care facility.

    Science.gov (United States)

    Fendler, E J; Ali, Y; Hammond, B S; Lyons, M K; Kelley, M B; Vowell, N A

    2002-06-01

    Nosocomial infections are a major problem in health care facilities, resulting in extended durations of care and substantial morbidity. Since alcohol gel hand sanitizers combine high immediate antimicrobial efficacy with ease of use, this study was carried out to determine the effect of the use of alcohol gel hand sanitizer by caregivers on infection types and rates in an extended care facility. Infection rate and type data were collected in a 275-bed extended care facility for 34 months (July 1997 to May 2000), during which an alcohol gel hand sanitizer was used by the caregivers in 2 units of the facility. The primary infection types found were urinary tract with Foley catheter, respiratory tract, and wound infections. Comparison of the infection types and rates for the units where hand sanitizer was used with those for the control units where the hand sanitizer was not used showed a 30.4% decrease in infection rates for the 34-month period in the units where hand sanitizer was used. This study indicates that use of an alcohol gel hand sanitizer can decrease infection rates and provide an additional tool for an effective infection control program.

  14. Trade reforms, mark-ups and bargaining power of workers: the case ...

    African Journals Online (AJOL)

    Ethiopian Journal of Economics ... workers between 1996 and 2007, a model of mark-up with labor bargaining power was estimated using random effects and LDPDM. ... Keywords: Trade reform, mark-up, bargaining power, rent, trade unions ...

  15. Effect of various practical warm-up protocols on acute lower-body power.

    Science.gov (United States)

    Buttifant, David; Hrysomallis, Con

    2015-03-01

    The purpose of this study was to compare the acute effect of box squats with barbell (BBSquat), box squats with elastic resistance bands (BandSquat), and static stretches (SStretch) on external power during a 20-kg weighted jump squat. Twelve male athletes performed each of the 3 warm-up protocols on separate occasions in a randomized order. Weighted jump squat power was assessed using a linear position transducer attached to the bar of a Smith machine. Jump power was measured pre-warm-up and 5 and 10 minutes post-warm-up protocol. The BBSquat protocol involved 3 sets of 3RM, BandSquat involved 3 sets of 3 repetitions using highest resistance elastic bands, and the SStretch protocol comprises two 30-second stretches for muscles of the lower limbs. Jump power significantly increased from pre-warm-up to 5 and 10 minutes post-warm-up for both the BandSquat and BBSquat protocols. There was no statistical difference in power values between BandSquat and BBSquat. Power output significantly decreased from pre-warm-up to 5 and 10 minutes post-warm-up for the SStretch protocol. The BandSquat was just as effective as BBSquat in augmenting acute jump power. The SStretch was detrimental to jump performance. A practical warm-up using relatively inexpensive and portable equipment such as elastic resistance bands was just as effective as a warm-up protocol that requires more substantial and less transportable equipment such as a squat rack and associated free weights. The BandSquat warm-up may be considered more accessible for athletes at various competition levels.

  16. 78 FR 47695 - Sam Rayburn Dam Power Rate

    Science.gov (United States)

    2013-08-06

    ... DEPARTMENT OF ENERGY Southwestern Power Administration Sam Rayburn Dam Power Rate AGENCY: Southwestern Power Administration, DOE. ACTION: Notice of public review and comment. SUMMARY: The current Sam..., Southwestern Power Administration (Southwestern), has prepared Current and Revised 2013 Power Repayment Studies...

  17. Space and power: young mothers' management of smoking in extended families in China.

    Science.gov (United States)

    Mao, Aimei

    2013-05-01

    Multigenerational co-residence is a widespread phenomenon in China but there is little knowledge about the impact of power dynamics on smoking behaviors among extended family residents. Using a gender lens, this ethnographic study explored how young mothers in extended families in mainland China managed the smoking of their husbands and other family members. Analysis of data resulted in a model of 'two units-three domains' to reflect gendered relationships between young mothers and other family members, and young mothers' participation in family management. Exploration of the mothers' efforts to deal with household smoking using the model provided an explanation for why the young mothers had limited control over household space and could only impose partial restrictions on home smoking in the extended family. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Extended blackout mitigation strategy for PWR

    International Nuclear Information System (INIS)

    Prošek, Andrej; Volkanovski, Andrija

    2015-01-01

    Highlights: • Equipment for mitigation of the extended blackout is investigated. • Analysis is done with deterministic safety analysis methods. • Strategy to prevent core heatup and not overfill steam generator is proposed. • Six types of reactor coolant system loss scenarios are investigated. • Pump flowrates and available start time to feed steam generators is determined. - Abstract: The accident at the Fukushima Daiichi nuclear power plant demonstrated the vulnerability of the plants on the loss of electrical power and loss of the ultimate heat sink events. A set of measures are proposed and currently implemented in response of the accident at the Fukushima Daiichi nuclear power plant. Those measures include diverse and flexible mitigation strategies that increase the defence-in-depth for beyond-design-basis scenarios. Mitigation strategies are based on the utilization of the portable equipment to provide power and water to the nuclear power plants in order to maintain or restore key safety functions. The verification of the proposed measures with the plant specific safety analyses is endorsed in the mitigation strategies. This paper investigates utilization of the turbine driven auxiliary feedwater pump (TD-AFW) or portable water injection pump for the mitigation of the event of loss of all alternate current sources and batteries (extended station blackout). Methodology for assessment of the required pump injection flow rate with the application of the standard deterministic safety analysis code is developed and presented. The required injection rate to the steam generators is calculated from the cumulative water mass injected by the turbine driven auxiliary feedwater pump in the analysed scenarios, when desired normal level is maintained automatically. The developed methodology allows assessment of the required injections rates of pump, TD-AFW or portable, for different plant configurations and number of flow rate changes. The methodology is applied

  19. Extended blackout mitigation strategy for PWR

    Energy Technology Data Exchange (ETDEWEB)

    Prošek, Andrej, E-mail: andrej.prosek@ijs.si; Volkanovski, Andrija, E-mail: andrija.volkanovski@ijs.si

    2015-12-15

    Highlights: • Equipment for mitigation of the extended blackout is investigated. • Analysis is done with deterministic safety analysis methods. • Strategy to prevent core heatup and not overfill steam generator is proposed. • Six types of reactor coolant system loss scenarios are investigated. • Pump flowrates and available start time to feed steam generators is determined. - Abstract: The accident at the Fukushima Daiichi nuclear power plant demonstrated the vulnerability of the plants on the loss of electrical power and loss of the ultimate heat sink events. A set of measures are proposed and currently implemented in response of the accident at the Fukushima Daiichi nuclear power plant. Those measures include diverse and flexible mitigation strategies that increase the defence-in-depth for beyond-design-basis scenarios. Mitigation strategies are based on the utilization of the portable equipment to provide power and water to the nuclear power plants in order to maintain or restore key safety functions. The verification of the proposed measures with the plant specific safety analyses is endorsed in the mitigation strategies. This paper investigates utilization of the turbine driven auxiliary feedwater pump (TD-AFW) or portable water injection pump for the mitigation of the event of loss of all alternate current sources and batteries (extended station blackout). Methodology for assessment of the required pump injection flow rate with the application of the standard deterministic safety analysis code is developed and presented. The required injection rate to the steam generators is calculated from the cumulative water mass injected by the turbine driven auxiliary feedwater pump in the analysed scenarios, when desired normal level is maintained automatically. The developed methodology allows assessment of the required injections rates of pump, TD-AFW or portable, for different plant configurations and number of flow rate changes. The methodology is applied

  20. Independent power project finance rating criteria

    International Nuclear Information System (INIS)

    Goldsmith, D.; Chew W.; Moulton, C.

    1992-01-01

    Continuing growth of project financing for non-utility generators in the US and abroad has led to growing focus on their credit strength. In general, the financings remain relatively risky and would likely be rated below investment grade, because of various factors: loose power purchase arrangements, poor match between power pricing and fuel costs, aggressive leverage, troubled operating performance. But S and P believes some projects have the credit strength to support investment grade ratings. As traditional financing markets for these projects --- bank lending and private placements with highly specialized institutional investors --- have contracted, project sponsors and developers are considering broader markets. These include institutional investors without specialized focus on power project finance. In these markets, distinctions among projects may lead to greater liquidity and efficiency in developing the pricing and terms under which projects can be financed. This paper reports that ratings are most appropriate for projects seeking permanent financing as they enter commercial operations. They also may be useful for projects which have been operating for some time and for some very strong projects which are raising construction financing. To guide both project developers and investors in project financing, S and P has developed the following approach for rating these types of financings

  1. Introduction of fuel GE14 in the nuclear power plant of Laguna Verde for the extended increase of power

    International Nuclear Information System (INIS)

    Hernandez M, N.; Vargas A, A. F.; Cardenas J, J. B.; Contreras C, P.

    2008-01-01

    The project of extended increase of power responds to a necessity of electrical energy in the country, increasing the thermal exit of the reactors of the nuclear power plant of Laguna Verde of 2027 MWt to 2317 MWt. In order to support this transition, changes will make in the configuration of the reactor core and in the operation strategies of the cycle, also they will take initiatives to optimize the economy in fuel cycle. At present in both reactors of the nuclear plant of Laguna Verde fuel GE12 is used. The fuel GE14 presents displays with respect to the GE12, some improvements in the mechanical design and consequently in its performance generally. Between these improvements we can mention: 1. Spacers of high performance. 2. Shielding with barrier. 3. Filter for sweepings d ebris a nd 4. Fuel rods of minor partial length. The management of nuclear power plants has decided to introduce the use of fuel GE14 in Laguna Verde in the reload 14 for Unit 1 and of the reload 10 for Unit 2. The process of new introduction fuel GE14 consists of two stages, first consists on subjecting the one new design of fuel to the regulator organism in the USA: Nuclear Regulatory Commission, in Mexico the design must be analyzed and authorized by the National Commission of Nuclear Safety and Safeguards, for its approval of generic form, by means of the demonstration of the fulfillment with the amendment 22 of GESTAR II, the second stage includes the specific analyses of plant to justify the use of the new fuel design in a reload core. The nuclear plant of Laguna Verde would use some of the results of the security analyses that have been realized for the project of extended increase of power with fuel GE14, to document the specific analyses of plant with the new fuel design. The result of the analyses indicates that the reload lots are increased of 116-120 assemblies in present conditions (2027 MWt) to 140-148 assemblies in conditions of extended increase of power (2317 MWt). (Author)

  2. Reserve lithium-thionyl chloride battery for high rate extended mission applications

    Science.gov (United States)

    Peabody, Mark; Brown, Robert A.

    An effort has been made to develop technology for lithium-thionyl chloride batteries whose emission times will extend beyond 20 min and whose power levels will be in excess of 1800 W, using the requirements for an existing silver-zinc battery's electrical requirements as a baseline. The target design encompasses separate 31- and 76-V sections; the design goal was the reduction of battery weight to 50 percent that of the present silver/zinc cell. A cell has been achieved whose mission can be conducted without container heat losses.

  3. Experimental evaluation of open-loop UpLink Power Control using ACTS

    Science.gov (United States)

    Dissanayake, Asoka

    1995-01-01

    The present investigation deals with the implementation of open-loop up-link power control using a beacon signal in the down-link frequency band as the control parameter. A power control system was developed and tested using the ACTS satellite. ACTS carries beacon signals in both up- and down-link bands with which the relationship between the up- and down-link fading can be established. A power controlled carrier was transmitted to the ACTS satellite from a NASA operated ground station and the transponded signal was received at COMSAT Laboratories using a terminal that was routinely used to monitor the two ACTS beacon signals. The experiment ran for a period of approximately six months and the collected data were used to evaluate the performance of the power control system. A brief review of propagation factors involved in estimating the up-link fade using a beacon signal in the down-link band are presented. The power controller design and the experiment configuration are discussed. Results of the experiment are discussed.

  4. Sensitivity Analysis of Core Damage by Loss of Auxiliary Feed Water during the Extended Loss of All AC Power

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Woo Jae; Chung, Soon Il; Hwang, Su Hyun; Lee, Kyung Jin; Lee, Byung Chul [FNC Tech., Yongin (Korea, Republic of); Yun, Duk Joo; Lee, Seung Chan [Korea Hydro and Nuclear Power Co. Ltd., Daejeon (Korea, Republic of)

    2015-10-15

    In this study, the reactor core damage time for OPR1000 type Nuclear Power Plant (NPP) was analyzed to develop a strategy to handle ELAP and to apply to the EOP. The reactor core damage time in the ELAP condition was calculated according to the time of Auxiliary Feedwater (AFW) loss. Fukushima accident was caused by long hours of Station Black Out (SBO) caused by natural disaster beyond Design Based Accident (DBA) criteria. It led to the reactor core damage. After the accident, the regulatory authorities of each country (Japan, US, EU, IAEA, and etc.) recommended developing the necessary systems and strategies in order to cover up the Extended Loss of All AC Power (ELAP) such as one occurred in the Fukushima accident. And the need of procedure or guideline to cope with ELAP has been raised through the stress test for Wolsong Nuclear Power Plant unit 1. Current Emergency Operating Procedures (EOP) used in domestic nuclear power plant are seemed to be insufficient to cope with ELAP. Therefore, it has been required to be improved. As the result, the time of AFW loss in the ELAP condition influences greatly on core damage time.

  5. Power ramp rate capabilities of a 5 kW proton exchange membrane fuel cell system with discrete ejector control

    Science.gov (United States)

    Nikiforow, K.; Pennanen, J.; Ihonen, J.; Uski, S.; Koski, P.

    2018-03-01

    The power ramp rate capabilities of a 5 kW proton exchange membrane fuel cell (PEMFC) system are studied theoretically and experimentally for grid support service applications. The fuel supply is implemented with a fixed-geometry ejector and a discrete control solution without any anode-side pressure fluctuation suppression methods. We show that the stack power can be ramped up from 2.0 kW to 4.0 kW with adequate fuel supply and low anode pressure fluctuations within only 0.1 s. The air supply is implemented with a centrifugal blower. Air supply ramp rates are studied with a power increase executed within 1 and 0.2 s after the request, the time dictated by grid support service requirements in Finland and the UK. We show that a power ramp-up from 2.0 kW to 3.7 kW is achieved within 1 s with an initial air stoichiometry of 2.5 and within 0.2 s with an initial air stoichiometry of 7.0. We also show that the timing of the power ramp-up affects the achieved ancillary power capacity. This work demonstrates that hydrogen fueled and ejector-based PEMFC systems can provide a significant amount of power in less than 1 s and provide valuable ancillary power capacity for grid support services.

  6. PUREX SAMCONS uninterruptible power supply (UPS) acceptance test report

    International Nuclear Information System (INIS)

    Blackaby, W.B.

    1997-01-01

    This Acceptance Test Report for the PUREX Surveillance and Monitoring and Control System (SAMCONS) Uninterruptible Power Supply (UPS) Acceptance Test Procedure validates the operation of the UPS, all alarming and display functions and the ability of the UPS to supply power to the SAMCONS as designed. The proper installation of the PUREX SAMCONS Trailer UPS components and wiring will be systematically evaluated by performance of this procedure. Proper operation of the SAMCONS computer UPS will be verified by performance of a timed functional load test, and verification of associated alarms and trouble indications. This test procedure will be performed in the SAMCONS Trailer and will include verification of receipt of alarms at the SAMCONS computer stations. This test may be performed at any time after the completion of HNF-SD-CP-ATP-083, PUREX Surveillance and Monitoring and Control System (SAMCONS) Acceptance Test Procedure, when computer display and alarm functions have been proven to operate correctly

  7. Wake-up receiver based ultra-low-power WBAN

    CERN Document Server

    Lont, Maarten; Roermund, Arthur van

    2014-01-01

    This book presents the cross-layer design and optimization of wake-up receivers for wireless body area networks (WBAN), with an emphasis on low-power circuit design. This includes the analysis of medium access control (MAC) protocols, mixer-first receiver design, and implications of receiver impairments on wideband frequency-shift-keying (FSK) receivers. Readers will learn how the overall power consumption is reduced by exploiting the characteristics of body area networks. Theoretical models presented are validated with two different receiver implementations, in 90nm and 40nm CMOS technology.   • Provides an overview of wireless body area network design from the network layer to the circuit implementation, and an overview of the cross-layer design trade-offs; • Discusses design at both the network or MAC-layer and circuit-level, with an emphasis on circuit design; • Covers the design of low-power frequency shift keying (FSK) wake-up-receivers; • Validates theory presented with two different recei...

  8. Start-up fuel and power flattening of sodium-cooled candle core

    International Nuclear Information System (INIS)

    Takaki, Naoyuki; Sagawa, Yu; Umino, Akitake; Sekimoto, Hiroshi

    2013-01-01

    The hard neutron spectrum and unique power shape of CANDLE enable its distinctive performances such as achieving high burnup more than 30% and exempting necessity of both enrichment and reprocessing. On the other hand, they also cause several challenging problems. One is how the initial fuel can be prepared to start up the first CANDLE reactor because the equilibrium fuel composition that enables stable CANDLE burning is complex both in axial and radial directions. Another prominent problem is high radial power peaking factor that worsens averaged burnup, namely resource utilization factor in once-through mode and shorten the life time of structure materials. The purposes of this study are to solve these two problems. Several ideas for core configurations and startup fuel using single enrichment uranium and iron as a substitute of fission products are studied. As a result, it is found that low enriched uranium is applicable to ignite the core but all concepts examined here exceeded heat limits. Adjustment in enrichment and height of active and burnt zone is opened for future work. Sodium duct assemblies and thorium fuel assemblies loaded in the center region are studied as measures to reduce radial power peaking factor. Replacing 37 fuels by thorium fuel assemblies in the zeroth to third row provides well-balanced performance with flattened radial power distribution. The CANDLE core loaded with natural uranium in the outer and thorium in the center region achieved 35.6% of averaged burnup and 7.0 years of cladding life time owing to mitigated local fast neutron irradiation at the center. Using thorium with natural or depleted uranium in CANDLE reactor is also beneficial to diversifying fission resource and extending available term of fission energy without expansion of needs for enrichment and reprocessing

  9. Effects of confinement on the dielectric response of water extends up to mesoscale dimensions

    DEFF Research Database (Denmark)

    De Luca, Sergio; Kannam, Sridhar Kumar; Todd, B.D.

    2016-01-01

    of confined water under the influence of external electric fields along with the dipolar fluctuations at equilibrium. The confinement induces a strong anisotropic effect which is evident up to 100 nm channel width, and may extend to macroscopic dimensions. The root-mean-square fluctuations of the total...... dimensions. Consistent with dipole moment fluctuations, the effect of confinement on the dielectric response also persists up to channel widths considerably beyond 100 nm. When an electric field is applied in the perpendicular direction, the orientational relaxation is 3 orders of magnitude faster than...

  10. Heart-Rate Recovery After Warm-up in Swimming: A Useful Predictor of Training Heart-Rate Response?

    Science.gov (United States)

    Ganzevles, Sander P M; de Haan, Arnold; Beek, Peter J; Daanen, Hein A M; Truijens, Martin J

    2017-07-01

    For training to be optimal, daily training load has to be adapted to the momentary status of the individual athlete, which is often difficult to establish. Therefore, the current study investigated the predictive value of heart-rate recovery (HRR) during a standardized warm-up for training load. Training load was quantified by the variation in heart rate during standardized training in competitive swimmers. Eight female and 5 male Dutch national-level swimmers participated in the study. They all performed 3 sessions consisting of a 300-m warm-up test and a 10 × 100-m training protocol. Both protocols were swum in front crawl at individually standardized velocities derived from an incremental step test. Velocity was related to 75% and 85% heart-rate reserve (% HR res ) for the warm-up and training, respectively. Relative HRR during the first 60 s after the warm-up (HR Rw-up ) and differences between the actual and intended heart rate for the warm-up and the training (ΔHR w-up and ΔHR tr ) were determined. No significant relationship between HRR w-up and ΔHR tr was found (F 1,37 = 2.96, P = .09, R 2 = .07, SEE = 4.65). There was considerable daily variation in ΔHR tr at a given swimming velocity (73-93% HR res ). ΔHR w-up and ΔHR tr were clearly related (F 1,37 = 74.31, P warm-up does not predict heart rate during a directly subsequent and standardized training session. Instead, heart rate during the warm-up protocol seems a promising alternative for coaches to make daily individual-specific adjustments to training programs.

  11. Effect of extended follow-up in a specialized heart failure clinic on adherence to guideline recommended therapy

    DEFF Research Database (Denmark)

    Schou, Morten; Gislason, Gunnar; Videbaek, Lars

    2014-01-01

    AIMS: The optimal duration of a public heart failure (HF) clinic programme is unknown. This substudy of the NT-proBNP stratified follow-up in outpatient heart failure clinics (NorthStar) trial was designed to evaluate the effect of extended follow-up in an outpatient HF clinic on long...

  12. Closed cycle high-repetition-rate pulsed HF laser

    Science.gov (United States)

    Harris, Michael R.; Morris, A. V.; Gorton, Eric K.

    1997-04-01

    The design and performance of a closed cycle high repetition rate HF laser is described. A short pulse, glow discharge is formed in a 10 SF6:1 H2 gas mixture at a total pressure of approximately 110 torr within a 15 by 0.5 by 0.5 cm3 volume. Transverse, recirculated gas flow adequate to enable repetitive operation up to 3 kHz is imposed by a centrifugal fan. The fan also forces the gas through a scrubber cell to eliminate ground state HF from the gas stream. An automated gas make-up system replenishes spent gas removed by the scrubber. Typical mean laser output powers up to 3 W can be maintained for extended periods of operation.

  13. Extended rate equations

    International Nuclear Information System (INIS)

    Shore, B.W.

    1981-01-01

    The equations of motion are discussed which describe time dependent population flows in an N-level system, reviewing the relationship between incoherent (rate) equations, coherent (Schrodinger) equations, and more general partially coherent (Bloch) equations. Approximations are discussed which replace the elaborate Bloch equations by simpler rate equations whose coefficients incorporate long-time consequences of coherence

  14. A Performance Comparison Between Extended Kalman Filter and Unscented Kalman Filter in Power System Dynamic State Estimation

    DEFF Research Database (Denmark)

    Khazraj, Hesam; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2016-01-01

    Dynamic State Estimation (DSE) is a critical tool for analysis, monitoring and planning of a power system. The concept of DSE involves designing state estimation with Extended Kalman Filter (EKF) or Unscented Kalman Filter (UKF) methods, which can be used by wide area monitoring to improve......-linear state estimator is developed in MatLab to solve states by applying the unscented Kalman filter (UKF) and Extended Kalman Filter (EKF) algorithm. Finally, a DSE model is built for a 14 bus power system network to evaluate the proposed algorithm for the networks.This article will focus on comparing...

  15. Rates of opioid dispensing and overdose after introduction of abuse-deterrent extended-release oxycodone and withdrawal of propoxyphene.

    Science.gov (United States)

    Larochelle, Marc R; Zhang, Fang; Ross-Degnan, Dennis; Wharam, J Frank

    2015-06-01

    In the second half of 2010, abuse-deterrent extended-release oxycodone hydrochloride (OxyContin; Purdue Pharma) was introduced and propoxyphene was withdrawn from the US market. The effect of these pharmaceutical market changes on opioid dispensing and overdose rates is unknown. To evaluate the association between 2 temporally proximate changes in the opioid market and opioid dispensing and overdose rates. Claims from a large national US health insurer were analyzed, using an interrupted time series study design. Participants included an open cohort of 31.3 million commercially insured members aged 18 to 64 years between January 1, 2003, and December 31, 2012, with median follow-up of 20 months (last follow-up, December 31, 2012). Introduction of abuse-deterrent OxyContin (resistant to crushing or dissolving) on August 9, 2010, and market withdrawal of propoxyphene on November 19, 2010. Standardized opioid dispensing rates and prescription opioid and heroin overdose rates were the primary outcomes. We used segmented regression to analyze changes in outcomes from 30 quarters before to 8 quarters after the 2 interventions. Two years after the opioid market changes, total opioid dispensing decreased by 19% from the expected rate (absolute change, -32.2 mg morphine-equivalent dose per member per quarter [95% CI, -38.1 to -26.3]). By opioid subtype, the absolute change in dispensing by milligrams of morphine-equivalent dose per member per quarter at 2 years was -11.3 (95% CI, -12.4 to -10.1) for extended-release oxycodone, 3.26 (95% CI, 1.40 to 5.12) for other long-acting opioids, -8.19 (95% CI, -9.30 to -7.08) for propoxyphene, and -16.2 (95% CI, -18.8 to -13.5) for other immediate-release opioids. Two years after the market changes, the estimated overdose rate attributed to prescription opioids decreased by 20% (absolute change, -1.10 per 100,000 members per quarter [95% CI, -1.47 to -0.74]), but heroin overdose increased by 23% (absolute change, 0.26 per 100

  16. A Method of Dynamic Extended Reactive Power Optimization in Distribution Network Containing Photovoltaic-Storage System

    Science.gov (United States)

    Wang, Wu; Huang, Wei; Zhang, Yongjun

    2018-03-01

    The grid-integration of Photovoltaic-Storage System brings some undefined factors to the network. In order to make full use of the adjusting ability of Photovoltaic-Storage System (PSS), this paper puts forward a reactive power optimization model, which are used to construct the objective function based on power loss and the device adjusting cost, including energy storage adjusting cost. By using Cataclysmic Genetic Algorithm to solve this optimization problem, and comparing with other optimization method, the result proved that: the method of dynamic extended reactive power optimization this article puts forward, can enhance the effect of reactive power optimization, including reducing power loss and device adjusting cost, meanwhile, it gives consideration to the safety of voltage.

  17. Energy, Electricity and Nuclear Power Estimates for the Period up to 2050. 2010 Ed

    International Nuclear Information System (INIS)

    2010-01-01

    Reference Data Series No. 1 (RDS-1) is an annual publication - currently in its thirtieth edition - containing estimates of energy, electricity and nuclear power trends up to the year 2050. RDS-1 starts with a summary of the situation of nuclear power in IAEA Member States as of the end of 2009. The data on nuclear power are based on actual statistical data collected by the IAEA's Power Reactor Information System (PRIS). Energy and electricity data for 2009, however, are estimated, since the latest available information from the United Nations Department of Economic and Social Affairs is for 2007. Population data originate from the World Population Prospects (2008 revision), published by the Population Division of the United Nations Department of Economic and Social Affairs, and the 2009 values again are estimates. As in the past, projections of future needs of energy, electricity and nuclear power are presented as low and high estimates encompassing the inherent uncertainties involved in projecting trends. The RDS-1 estimates should be viewed as very general growth trends whose validity must be constantly subjected to critical review. Beginning with the 30th edition of this publication, however, the end-point of the estimates is extended up to the year 2050 (instead of 2030). Looking beyond 2030 is prompted by the interest expressed by numerous Member States currently without nuclear power in adding nuclear energy to their future national energy supply mixes. Given the lead times in planning and implementing nuclear power programmes, a fair share of these are likely to result in actual plant commissioning and grid connection after 2030. Many international, national and private organizations routinely engage in energy demand and supply projections, including nuclear power. These projections are based on a multitude of different assumptions and aggregating procedures, which make a straightforward comparison and synthesis very difficult. The basic differences refer

  18. Wind power in Finland up to the year 2025--'soft' scenarios based on expert views

    International Nuclear Information System (INIS)

    Varho, Vilja; Tapio, Petri

    2005-01-01

    In this article we present a method of constructing 'soft' scenarios applied to the wind power development in Finland up to the year 2025. We asked 14 experts to describe probable and preferable futures using a quantitative questionnaire and qualitative interviews. Wind power production grows in all scenarios but there were differences in the order of magnitude of 10. The growth rate of electricity consumption slows down in all scenarios. Qualitative arguments varied even within clusters, with wind power policy emerging as the main dividing factor. The differences revealed diverse values and political objectives, as well as great uncertainties in assumptions about future developments. These influence wind power policy and were also believed to have contributed to the slow development of wind power in Finland. Re-thinking of the Finnish wind power policy is recommended. The 'soft' scenario method is considered valuable in finding diverse views, constructing transparent scenarios and assisting energy policy making

  19. Analysis on the Impact of Pop-Up Flight Occurrence when Extending the Arrival Management Horizon

    NARCIS (Netherlands)

    Ellerbroek, J.; Hoekstra, J.M.; Westerveld, E

    2017-01-01

    The occurrence of pop-up flights negatively affects the (extended) arrival manager. This issue is known already for a long time by operational experts, but the extent thereof has now been assessed during experiments. An arrival manager research model was developed and integrated in BlueSky, an

  20. On-line validation of feedwater flow rate in nuclear power plants using neural networks

    International Nuclear Information System (INIS)

    Khadem, M.; Ipakchi, A.; Alexandro, F.J.; Colley, R.W.

    1994-01-01

    On-line calibration of feedwater flow rate measurement in nuclear power plants provides a continuous realistic value of feedwater flow rate. It also reduces the manpower required for periodic calibration needed due to the fouling and defouling of the venturi meter surface condition. This paper presents a method for on-line validation of feedwater flow rate in nuclear power plants. The method is an improvement of the previously developed method which is based on the use of a set of process variables dynamically related to the feedwater flow rate. The online measurements of this set of variables are used as inputs to a neural network to obtain an estimate of the feedwater flow rate reading. The difference between the on-line feedwater flow rate reading, and the neural network estimate establishes whether there is a need to apply a correction factor to the feedwater flow rate measurement for calculation of the actual reactor power. The method was applied to the feedwater flow meters in the two feedwater flow loops of the TMI-1 nuclear power plant. The venturi meters used for flow measurements are susceptible to frequent fouling that degrades their measurement accuracy. The fouling effects can cause an inaccuracy of up to 3% relative error in feedwater flow rate reading. A neural network, whose inputs were the readings of a set of reference instruments, was designed to predict both feedwater flow rates simultaneously. A multi-layer feedforward neural network employing the backpropagation algorithm was used. A number of neural network training tests were performed to obtain an optimum filtering technique of the input/output data of the neural networks. The result of the selection of the filtering technique was confirmed by numerous Fast Fourier Transform (FFT) tests. Training and testing were done on data from TMI-1 nuclear power plant. The results show that the neural network can predict the correct flow rates with an absolute relative error of less than 2%

  1. Power control system in BWR type reactors

    International Nuclear Information System (INIS)

    Nishizawa, Yasuo.

    1980-01-01

    Purpose: To control the reactor power so that the power distribution can satisfy the limiting conditions, by regulating the reactor core flow rate while monitoring the power distribution in the reactor core of a BWR type reactor. Constitution: A power distribution monitor determines the power distribution for the entire reactor core based on the data for neutron flux, reactor core thermal power, reactor core flow rate and control rod pattern from the reactor and calculates the linear power density distribution. A power up ratio computing device computes the current linear power density increase ratio. An aimed power up ratio is determined by converting the electrical power up ratio transferred from a load demand input device into the reactor core thermal power up ratio. The present reactor core thermal power up ratio is subtracted from the limiting power up ratio and the difference is sent to an operation amount indicator and the reactor core flow rate is changed in a reactor core flow rate regulator, by which the reactor power is controlled. (Moriyama, K.)

  2. Power spectral analysis of heart rate in hyperthyroidism.

    Science.gov (United States)

    Cacciatori, V; Bellavere, F; Pezzarossa, A; Dellera, A; Gemma, M L; Thomaseth, K; Castello, R; Moghetti, P; Muggeo, M

    1996-08-01

    The aim of the present study was to evaluate the impact of hyperthyroidism on the cardiovascular system by separately analyzing the sympathetic and parasympathetic influences on heart rate. Heart rate variability was evaluated by autoregressive power spectral analysis. This method allows a reliable quantification of the low frequency (LF) and high frequency (HF) components of the heart rate power spectral density; these are considered to be under mainly sympathetic and pure parasympathetic control, respectively. In 10 newly diagnosed untreated hyperthyroid patients with Graves' disease, we analyzed power spectral density of heart rate cyclic variations at rest, while lying, and while standing. In addition, heart rate variations during deep breathing, lying and standing, and Valsalva's maneuver were analyzed. The results were compared to those obtained from 10 age-, sex-, and body mass index-matched control subjects. In 8 hyperthyroid patients, the same evaluation was repeated after the induction of stable euthyroidism by methimazole. Heart rate power spectral analysis showed a sharp reduction of HF components in hyperthyroid subjects compared to controls [lying, 13.3 +/- 4.1 vs. 32.0 +/- 5.6 normalized units (NU; P hyperthyroid subjects while both lying (11.3 +/- 4.5 vs. 3.5 +/- 1.1; P hyperthyroid patients than in controls (1.12 +/- 0.03 vs. 1.31 +/- 0.04; P activity and, thus, a relative hypersympathetic tone.

  3. Life Insurance Take-Up Rate Influencing Factors Comparison between Malaysia and Japan

    Directory of Open Access Journals (Sweden)

    Silvana Kardinar Wijayanti

    2016-08-01

    Full Text Available This study will investigate the factors that influence take-up rates within the Malaysian Life Insurance industry to discover potential opportunities and limitations. For comparative purposes, the study is modelled on Power (2013 who examined four factors affecting customer satisfaction in life insurance in Japan (product, price, customer services and procedures and documentation. This study is exploratory in nature using both secondary research and primary data from questionnaires. The main finding was “Product offerings” being the most significant variation, both an opportunity and limitation, due to the relative maturity, experience and changing trends within the insurance market of Japan, conversely growth, infancy and different dynamics in Malaysia.

  4. 76 FR 50726 - Integrated System Power Rates: Correction

    Science.gov (United States)

    2011-08-16

    ... DEPARTMENT OF ENERGY Southwestern Power Administration Integrated System Power Rates: Correction AGENCY: Southwestern Power Administration, DOE. ACTION: Notice of public review and comment; Correction... date listed for the combined Public Information and Comment Forum (Forum) was erroneously listed in the...

  5. Performance of PWR Nuclear power plants, up to 1985

    International Nuclear Information System (INIS)

    Muniz, A.A.

    1987-01-01

    The performance of PWR nuclear power plants is studied, based on operational data up to 1985. The availability analysis was made with 793 unit-year and the reliability analysis was made with 5851 unit x month. The results were discussed and the availability of those nuclear power plants were estimated. (E.G.) [pt

  6. An improved power flow method based on extended chain-table storage structure for distribution network with PV nodes

    DEFF Research Database (Denmark)

    Chen, Shuheng; Wang, Xiongfei; Su, Chi

    2014-01-01

    with a reduced memory size. The voltage error of each PV node is adjusted by a reactive power adjusting strategy. The adjusting strategy is based on a multi-variable linear function with an accelerating factor. Finally, this new improved power flow method is realized by the software system developed in VC......Based on an extended chain-table storage structure, an improved power flow method is presented, which can be applied to a distribution network with multi PV nodes. The extended chain-table storage structure is designed on the basis of address-pointer technology describing the radial topology...... and the corresponding case study has been done. The experimental data and the further analysis have proved that this method can calculate the power flow of a distribution network with multi PV nodes precisely and fast. © 2014 IEEE....

  7. Assessment on Startup Ramp Rate and Threshold Power of OPR1000

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kiyoung; Kim, Yongbae; Cha, Gyunho; Kim, Yongdeog [Korea Hydro and Nuclear Power Co., Ltd., Daejeon (Korea, Republic of)

    2014-05-15

    This paper summarizes PCI assessment according to several startup ramp rates and threshold power assessment of OPR1000. The definition of threshold power is maximum value in power range that can increase startup ramp rate rapidly. FALCON code is used for PCI assessment and it is analyzed for once-burned fuel because it is the most sensitive to PCI failure. The objective of the PCI analysis is to assess the cladding stress state under various power ramp conditions at the peak power node location. The PCI analyses were conducted for the once-burned fuel from the start of the second cycle to plant power 100%. This paper presents both the PCI analysis according to startup ramp rates and threshold power assessment result like below. · The more startup ramp rate is increased, the more PCI failure probability is decreased in low power range (≤ 40%). · PCI failure is not occurred even though startup ramp rate is 10%/hr until the plant power reaches 55%.

  8. Assessment on Startup Ramp Rate and Threshold Power of OPR1000

    International Nuclear Information System (INIS)

    Kim, Kiyoung; Kim, Yongbae; Cha, Gyunho; Kim, Yongdeog

    2014-01-01

    This paper summarizes PCI assessment according to several startup ramp rates and threshold power assessment of OPR1000. The definition of threshold power is maximum value in power range that can increase startup ramp rate rapidly. FALCON code is used for PCI assessment and it is analyzed for once-burned fuel because it is the most sensitive to PCI failure. The objective of the PCI analysis is to assess the cladding stress state under various power ramp conditions at the peak power node location. The PCI analyses were conducted for the once-burned fuel from the start of the second cycle to plant power 100%. This paper presents both the PCI analysis according to startup ramp rates and threshold power assessment result like below. · The more startup ramp rate is increased, the more PCI failure probability is decreased in low power range (≤ 40%). · PCI failure is not occurred even though startup ramp rate is 10%/hr until the plant power reaches 55%

  9. A Comparative Risk Assessment of Extended Integrated Leak Rate Testing Intervals

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Ji Yong; Hwang, Seok Won; Lee, Byung Sik [Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of)

    2009-10-15

    This paper presents the risk impacts of extending the Integrated Leak Rate Testing (ILRT) intervals (from five years to ten years) of Yonggwang (YGN) Unit 1 and 2. These risk impacts depended on the annual variances of meteorological data and resident population. Main comparisons were performed between the initial risk assessment (2005) for the purpose of extending ILRT interval and risk reassessment (2009) where the changed plant internal configurations (core inventory and radioisotope release fraction) and plant external alterations (wind directions, rainfall and population distributions) were monitored. The reassessment showed that there was imperceptible risk increase when the ILRT interval was extended compared to the initial risk assessment. In addition, the increased value of the Large Early Release Frequency (LERF) also satisfied the acceptance guideline proposed on Reg. Guide 1.174. The MACCS II code was used for evaluating the offsite consequence analysis. The primary risk index were used as the Probabilistic Population Dose (PPD) by considering the early effects within 80 km. The Probabilistic Safety Assessment (PSA) of YGN 1 and 2 was applied to evaluate the accident frequency of each source term category and the used PSA scope was limited to internal event.

  10. Genealogical databases as a tool for extending follow-up in clinical reviews.

    Science.gov (United States)

    Ho, Thuy-Van; Chowdhury, Naweed; Kandl, Christopher; Hoover, Cindy; Robinson, Ann; Hoover, Larry

    2016-08-01

    Long-term follow-up in clinical reviews often presents significant difficulty with conventional medical records alone. Publicly accessible genealogical databases such as Ancestry.com provide another avenue for obtaining extended follow-up and added outcome information. No previous studies have described the use of genealogical databases in the follow-up of individual patients. Ancestry.com, the largest genealogical database in the United States, houses extensive demographic data on an increasing number of Americans. In a recent retrospective review of esthesioneuroblastoma patients treated at our institution, we used this resource to ascertain the outcomes of patients otherwise lost to follow-up. Additional information such as quality of life and supplemental treatments the patient may have received at home was obtained through direct contact with living relatives. The use of Ancestry.com resulted in a 25% increase (20 months) in follow-up duration as well as incorporation of an additional 7 patients in our study (18%) who would otherwise not have had adequate hospital chart data for inclusion. Many patients within this subset had more advanced disease or were remotely located from our institution. As such, exclusion of these outliers can impact the quality of subsequent outcome analysis. Online genealogical databases provide a unique resource of public information that is acceptable to institutional review boards for patient follow-up in clinical reviews. Utilization of Ancestry.com data led to significant improvement in follow-up duration and increased the number of patients with sufficient data that could be included in our retrospective study. © 2016 ARS-AAOA, LLC.

  11. International conference on management of spent fuel from nuclear power reactors. Book of extended synopses

    International Nuclear Information System (INIS)

    2006-01-01

    This document contains 48 extended synopses of the International Conference on Management of Spent Fuel from Nuclear Power Reactors. The major topics covered related to national programmes in spent fuel management as well as regional trends, technology and safety/security aspects of wet and dry storage, licensing and regulation, quality assurance, design control, operating experience, R and D, and special aspects of spent fuel storage including in-service inspection, robotics, heat removal, and other engineering considerations. Each of the extended synopses was indexed separately

  12. Prospects for nuclear power development in the medium term (up to 2000)

    International Nuclear Information System (INIS)

    Konstantinov, L.V.; Char, N.L.; Bennett, L.L.

    1986-10-01

    There were at the end of 1985 374 nuclear power plants, with a total capacity of 250 GW(e), in operation in the world. In energy, nuclear power plants accounted for some 14% of the world's electricity generation during 1985. Relatively high reserve capacities, uncertainties about future rates of growth in demand and financial constraints in most market economy countries seem to be the major reasons for the continuing low rate of ordering of new nuclear power plants. This may cause severe problems for the nuclear industry in the second half of this decade and may constrain the electricity supply during the 1990s, particularly in view of the possible decrease of new orders for fossil-fuelled plants also, which is at least partly due to increasing concern about the environmental impact of such plants. To meet even a low estimate of worldwide nuclear capacity of 505 GW(e), corresponding to a 13% nuclear share of the total electricity generating capacity (but providing about 20% of the total electrical energy production), by the year 2000, some 125-150 GW(e) will have to be ordered between now and the early 1990s. The addition of this capacity appears reasonable in light of the fact that about the same increase will occur during 1985-1990. The developing countries will need to add some 600-800 GW(e) of generating capacity during the next 15 years, increasing their total installed capacity by a factor of 2.3 to 2.8. The IAEA estimates that, realistically, only some 35-75 GW(e) of these capacity additions up to 2000 would likely be with nuclear power plants. Thus, it is clear that, although nuclear power will be important in a few developing countries, most of the electricity needs in the developing world will continue to be met by other energy sources

  13. Valuing Euro rating-triggered step-up telecom bonds

    NARCIS (Netherlands)

    P. Houweling (Patrick); A.A. Mentink; A.C.F. Vorst (Ton)

    2003-01-01

    textabstractWe value rating-triggered step-up bonds with three methods: (i) the Jarrow, Lando and Turnbull (1997, JLT) framework, (ii) a similar framework using historical probabilities and (iii) as plain vanilla bonds. We find that the market seems to value single step-up bonds according to the JLT

  14. Valuing Euro Rating-Triggered Step-Up Telecom Bonds

    NARCIS (Netherlands)

    P. Houweling (Patrick); A.A. Mentink; A.C.F. Vorst (Ton)

    2003-01-01

    textabstractWe value rating-triggered step-up bonds with three methods: (i) the Jarrow, Lando and Turnbull (1997, JLT) framework, (ii) a similar framework using historical probabilities and (iii) as plain vanilla bonds. We find that the market seems to value single step-up bonds according to the JLT

  15. Extending dry storage of spent LWR fuel for up to 100 years

    International Nuclear Information System (INIS)

    Einziger, R.E.; McKinnon, M.A.; Machiels, A.J.

    1999-01-01

    Because of delays in closing the back end of the fuel cycle in the U.S., there is a need to extend dry inert storage of spent fuel beyond its originally anticipated 20-year duration. Many of the methodologies developed to support initial licensing for 20-year storage should be able to support the longer storage periods envisioned. This paper evaluates the applicability of existing information and methodologies to support dry storage up to 100 years. The thrust of the analysis is the potential behavior of the spent fuel. In the USA, the criteria for dry storage of LWR spent fuel are delineated in 10 CFR 72. The criteria fall into four general categories: maintain subcriticality, prevent the release of radioactive material above acceptable limits, ensure that radiation rates and doses do not exceed acceptable levels, and maintain retrievability of the stored radioactive material. These criteria need to be considered for normal, off-normal, and postulated accident conditions. The initial safety analysis report submitted for licensing evaluated the fuel's ability to meet the requirements for 20 years. It is not the intent to repeat these calculations, but to look at expected behavior over the additional 80 years, during which the temperatures and radiation fields are lower. During the first 20 years, the properties of the components may change because of elevated temperatures, presence of moisture, effects of radiation, etc. During normal storage in an inert atmosphere, there is potential for the cladding mechanical properties to change due to annealing or interaction with cask materials. The emissivity of the cladding could also change due to storage conditions. If there is air leakage into the cask, additional degradation could occur through oxidation in breached rods, which could lead to additional fission gas release and enlargement of cladding breaches. Air in-leakage could also affect cover gas conductivity, cladding oxidation, emissivity changes, and excessive

  16. Extending dry storage of spent LWR fuel for up to 100 years

    International Nuclear Information System (INIS)

    Einziger, R. E.

    1998-01-01

    Because of delays in closing the back end of the fuel cycle in the U.S., there is a need to extend dry inert storage of spent fuel beyond its originally anticipated 20-year duration. Many of the methodologies developed to support initial licensing for 20-year storage should be able to support the longer storage periods envisioned. This paper evaluates the applicability of existing information and methodologies to support dry storage up to 100 years. The thrust of the analysis is the potential behavior of the spent fuel. In the USA, the criteria for dry storage of LWR spent fuel are delineated in 10 CFR 72 [1]. The criteria fall into four general categories: maintain subcriticality, prevent the release of radioactive material above acceptable limits, ensure that radiation rates and doses do not exceed acceptable levels, and maintain retrievability of the stored radioactive material. These criteria need to be considered for normal, off-normal, and postulated accident conditions. The initial safety analysis report submitted for licensing evaluated the fuel's ability to meet the requirements for 20 years. It is not the intent to repeat these calculations, but to look at expected behavior over the additional 80 years, during which the temperatures and radiation fields are lower. During the first 20 years, the properties of the components may change because of elevated temperatures, presence of moisture, effects of radiation, etc. During normal storage in an inert atmosphere, there is potential for the cladding mechanical properties to change due to annealing or interaction with cask materials. The emissivity of the cladding could also change due to storage conditions. If there is air leakage into the cask, additional degradation could occur through oxidation in breached rods, which could lead to additional fission gas release and enlargement of cladding breaches. Air in-leakage could also affect cover gas conductivity, cladding oxidation, emissivity changes, and

  17. The economic impact of giving up nuclear power in France

    International Nuclear Information System (INIS)

    Carnot, N.; Gallon, St.

    2001-01-01

    French nuclear plants will have to be shut down in the 2020's. Electricite de France (EDF) could replace them by either nuclear or gas-fired plants. Choosing the latter would lead to an increase in Green House Gases (GHG) emissions and to a rise of EDF's generation costs. In 2020, the price of electricity in Europe will be determined by a competitive market. Therefore, a rise of EDF's generation costs will mainly depress its operating profit (and slightly increase the market's price). Giving up nuclear power in 2020 would consequently lead to a fall of EDF's value and would penalize its shareholders, the State. On a macro-economic scale, the shock on the production cost of electricity would lead to a 0,5 to 1,0 percentage point drop of GDP (depending on the hypotheses). Structural unemployment would rise by 0,3 to 0,6 percentage point. The model used to find these results does not take into account the risk of nuclear accidents nor the uncertainty on the costs of nuclear waste disposal. On the other hand, gas-price is assumed to be low, and the costs of gas-fired generation do not integrate the risk premium due to gas-price volatility. In conclusion, the best choice on both micro and macro scales, consists in extending the life of current nuclear plants (if such an extension is authorised by safety regulators). These plants would be financially-amortized, produce electricity at a very competitive cost and emit no GHG. Furthermore, extending the life of current nuclear plants will defer any irreversible commitment on their replacement. The necessary decision could therefore be taken later on, with more information on the cost of alternative generation technologies and their efficiency. (author)

  18. Summary revaluation of energetic start-up of the unit 1 of nuclear power plant Mochovce

    International Nuclear Information System (INIS)

    Sarvaic, I.; Miskolci, M.

    1998-01-01

    The document contents stage revaluation of energetic start-up of the unit 1 of nuclear power plant Mochovce. Test results of the stage of energetic start-up are summarized in the document, valuation of important systems and block devices as well as fulfilling the operation limits and conditions has been performed. On that base conclusions and recommendations for start-up the unit 2 and for commercial operation of the unit 1 are elaborated. The valuation has been elaborated by a scientific management for start-up nuclear power plant Mochovce of nuclear safety of nuclear power facilities. Scientific management for start-up of nuclear power plant Mochovce performed continuous valuation of individual power levels after ending of each individual level and it gave its valuation to energy power level with recommendations and conditions for further start-up process and operation. Scientific management finished its activity at the unit 1 of nuclear power plant Mochovce according to a statute of scientific management for start-up after successful completion of conclusive block run. Scientific management group was founded in February 1998 at nuclear power plant Mochovce. Its members are experts from Slovak, Czech, Russian and French organizations which are participating in power plant completion. Members are listed in a supplement No. 2

  19. Preliminary power supply design for the TF coil system of CIT

    International Nuclear Information System (INIS)

    Neumeyer, C.; Bronner, G.; Huttar, D.

    1989-01-01

    Initial operation of the Compact Ignition Tokamak (CIT) is planned with a Toroidal Field (TF) of 8 Tesla and a flat top duration of 5 seconds. Ultimately, operation will be extended beyond 8 Tesla. The power supply to be used for the initial phase of operation has been modeled using the parameters of the thyristor rectifier power supplies which are now in service for the Tokamak Fusion Test Reactor (TFTR). A subset of these existing units, or perhaps new units with similar ratings, are envisioned to be connected to the existing 138kV transmission line serving PPPL so as to take advantage of this power source for CIT. For the extended operation phase the equipment used for the initial phase of TF operation will be augmented with new equipment to permit operation up to 11 Tesla. This paper describes the preliminary design for the 8 Tesla power supply and presents results from simulation studies. In addition, issues concerning transient behavior and fault modes are discussed. 4 refs., 12 figs

  20. Effect of Remote Back-Up Protection System Failure on the Optimum Routine Test Time Interval of Power System Protection

    Directory of Open Access Journals (Sweden)

    Y Damchi

    2013-12-01

    Full Text Available Appropriate operation of protection system is one of the effective factors to have a desirable reliability in power systems, which vitally needs routine test of protection system. Precise determination of optimum routine test time interval (ORTTI plays a vital role in predicting the maintenance costs of protection system. In the most previous studies, ORTTI has been determined while remote back-up protection system was considered fully reliable. This assumption is not exactly correct since remote back-up protection system may operate incorrectly or fail to operate, the same as the primary protection system. Therefore, in order to determine the ORTTI, an extended Markov model is proposed in this paper considering failure probability for remote back-up protection system. In the proposed Markov model of the protection systems, monitoring facility is taken into account. Moreover, it is assumed that the primary and back-up protection systems are maintained simultaneously. Results show that the effect of remote back-up protection system failures on the reliability indices and optimum routine test intervals of protection system is considerable.

  1. Evaluating Upper-Body Strength and Power From a Single Test: The Ballistic Push-up.

    Science.gov (United States)

    Wang, Ran; Hoffman, Jay R; Sadres, Eliahu; Bartolomei, Sandro; Muddle, Tyler W D; Fukuda, David H; Stout, Jeffrey R

    2017-05-01

    Wang, R, Hoffman, JR, Sadres, E, Bartolomei, S, Muddle, TWD, Fukuda, DH, and Stout, JR. Evaluating upper-body strength and power from a single test: the ballistic push-up. J Strength Cond Res 31(5): 1338-1345, 2017-The purpose of this study was to examine the reliability of the ballistic push-up (BPU) exercise and to develop a prediction model for both maximal strength (1 repetition maximum [1RM]) in the bench press exercise and upper-body power. Sixty recreationally active men completed a 1RM bench press and 2 BPU assessments in 3 separate testing sessions. Peak and mean force, peak and mean rate of force development, net impulse, peak velocity, flight time, and peak and mean power were determined. Intraclass correlation coefficients were used to examine the reliability of the BPU. Stepwise linear regression was used to develop 1RM bench press and power prediction equations. Intraclass correlation coefficient's ranged from 0.849 to 0.971 for the BPU measurements. Multiple regression analysis provided the following 1RM bench press prediction equation: 1RM = 0.31 × Mean Force - 1.64 × Body Mass + 0.70 (R = 0.837, standard error of the estimate [SEE] = 11 kg); time-based power prediction equation: Peak Power = 11.0 × Body Mass + 2012.3 × Flight Time - 338.0 (R = 0.658, SEE = 150 W), Mean Power = 6.7 × Body Mass + 1004.4 × Flight Time - 224.6 (R = 0.664, SEE = 82 W); and velocity-based power prediction equation: Peak Power = 8.1 × Body Mass + 818.6 × Peak Velocity - 762.0 (R = 0.797, SEE = 115 W); Mean Power = 5.2 × Body Mass + 435.9 × Peak Velocity - 467.7 (R = 0.838, SEE = 57 W). The BPU is a reliable test for both upper-body strength and power. Results indicate that the mean force generated from the BPU can be used to predict 1RM bench press, whereas peak velocity and flight time measured during the BPU can be used to predict upper-body power. These findings support the potential use of the BPU as a valid method to evaluate upper-body strength and power.

  2. Extended power-law scaling of air permeabilities measured on a block of tuff

    Directory of Open Access Journals (Sweden)

    M. Siena

    2012-01-01

    Full Text Available We use three methods to identify power-law scaling of multi-scale log air permeability data collected by Tidwell and Wilson on the faces of a laboratory-scale block of Topopah Spring tuff: method of moments (M, Extended Self-Similarity (ESS and a generalized version thereof (G-ESS. All three methods focus on q-th-order sample structure functions of absolute increments. Most such functions exhibit power-law scaling at best over a limited midrange of experimental separation scales, or lags, which are sometimes difficult to identify unambiguously by means of M. ESS and G-ESS extend this range in a way that renders power-law scaling easier to characterize. Our analysis confirms the superiority of ESS and G-ESS over M in identifying the scaling exponents, ξ(q, of corresponding structure functions of orders q, suggesting further that ESS is more reliable than G-ESS. The exponents vary in a nonlinear fashion with q as is typical of real or apparent multifractals. Our estimates of the Hurst scaling coefficient increase with support scale, implying a reduction in roughness (anti-persistence of the log permeability field with measurement volume. The finding by Tidwell and Wilson that log permeabilities associated with all tip sizes can be characterized by stationary variogram models, coupled with our findings that log permeability increments associated with the smallest tip size are approximately Gaussian and those associated with all tip sizes scale show nonlinear variations in ξ(q with q, are consistent with a view of these data as a sample from a truncated version (tfBm of self-affine fractional Brownian motion (fBm. Since in theory the scaling exponents, ξ(q, of tfBm vary linearly with q we conclude that nonlinear scaling in our case is not an indication of multifractality but an artifact of sampling from tfBm. This allows us to explain theoretically how power-law scaling of our data, as well

  3. The Effect of Different Warm-up Protocols on young Soccer Players' Explosive Power

    Directory of Open Access Journals (Sweden)

    Mohamad Ali Mohamadi

    2012-12-01

    Full Text Available Objective: To investigating the effect of different Warm-up Protocols on young Soccer Players' Explosive Power. Methods: Twenty male soccer players (17.4 0.685 years volunteered to participate in this study. The participants were randomly selected, and in order to remove the effects of transmission and to observe the sequence of warm-up methods, they were cross-matched randomly e.g. 20 players in four categories; that is, 5 players in each category. The participants in each category experienced the 4 warm-up ways in four consecutive so that at the end 20 players performed each method of warm-up. Warm-up methods: 1. Static warm-up; 2. Dynamic warm-up plus 2 min active rest; 3. Dynamic warm-up plus 5 min passive rest and finally Dynamic warm-up plus 15 min passive rest. Participants in each category performed different warm-up methods which had been designed based on scientific and research-based sources in 48 hours intervals After performing each warm-up method, they were given a Long Jump. Results: Based on the results of analysis of variance between the effect of different warm-up methods on Explosive Power participants, significant difference was observed (p?0/05 so that Dynamic warm-up plus 5 min passive rest was more effective in Explosive Power performance than other methods(p?0/05. Discussion: The results of this study are in line with those of Roger (2008 and Faigenbaum et al (2006 who indicated in their studies that Dynamic or mixed method of warm-up are more effective than static ones. Conclusion: Therefore, with regard to the results of the study presented here and also the nature of football enjoying explosive power than the air blows, it is recommended that these types of protocols during warm-up program be employed.   Keywords: Warm up, Explosive Power , Soccer Players', Young  

  4. High RF power test of a lower hybrid module mock-up in Carbon Fiber Composite

    International Nuclear Information System (INIS)

    Maebara, Sunao; Kiyono, Kimihiro; Seki, Masami

    1997-11-01

    A mock-up module of a Lower Hybrid Current Drive antenna module of a Carbon Fiber Composite (CFC) was fabricated for the development of heat resistive front facing the plasma. This module is made from CFC plates and rods which are copper coated to reduce the RF losses. The withstand-voltage, the RF properties and outgassing rates for long pulses and high RF power were tested at the Lower Hybrid test bed facility of Cadarache. After the short pulse conditioning, long pulses with a power density ranging between 50 and 150 MW/m 2 were performed with no breakdowns. During these tests, the module temperature was increasing from 100-200degC to 400-500degC. It was also checked that high power density, up to 150 MW/m 2 , could be transmitted when the waveguides are filled with H 2 at a pressure of 5 x 10 -2 Pa. No significant change in the reflection coefficient is measured after the long pulse operation. During a long pulse, the power reflection increases during the pulse typically from 0.8 % to 1.3 %. It is concluded that the outgassing rate of Cu-plated CFC is about 6-7 times larger than of Dispersion Strengthened Copper (DSC) module at the module temperature of 300degC. No significant increase of the global outgassing of the CFC module was measured after hydrogen prefilling. After the test, visual inspection revealed that peeling of the copper coating occurred at one end of the module only on a very small area (0.2 cm 2 ). It is assessed that a CFC module is an attractive candidate for the hardening of the tip of the LHCD antenna. (author)

  5. High RF power test of a lower hybrid module mock-up in carbon fiber composite

    International Nuclear Information System (INIS)

    Goniche, M.; Bibet, P.; Brossaud, J.; Cano, V.; Froissard, P.; Kazarian, F.; Rey, G.; Maebara, S.; Kiyono, K.; Seki, M.; Suganuma, K.; Ikeda, Y.; Imai, T.

    1999-02-01

    A mock-up module of a Lower Hybrid Current Drive antenna module of a Carbon Fiber Composite (CFC) was fabricated for the development of heat resistive front facing the plasma. This module is made from CFC plates and rods which are copper coated to reduce the RF losses. The withstand-voltage, the RF properties and outgassing rates for long pulses and high RF power were tested at the Lower Hybrid test bed facility of Cadarache. After the short pulse conditioning, long pulses with a power density ranging between 50 and 150 MW/m 2 were performed with no breakdowns. During these tests, the module temperature was increasing from 100-200 deg. C to 400-500 deg. C. It was also checked that high power density, up to 150 MW/m 2 , could be transmitted when the waveguides are filled with H 2 at a pressure of 5 x 10 -2 Pa. No significant change in the reflection coefficient is measured after the long pulse operation. During a long pulse, the power reflection increases during the pulse typically from 0.8% to 1.3%. It is concluded that the outgassing rate of Cu-plated CFC is about 6 times larger than of Dispersion Strengthened Copper (DSC) module at the module temperature of 300 deg. C. No significant increase of the global outgassing of the CFC module was measured after hydrogen pre-filling. After the test, visual inspection revealed that peeling of the copper coating occurred at one end of the module only on a very small area (0.2 cm 2 ). It is assessed that a CFC module is an attractive candidate for the hardening of the tip of the LHCD antenna. (authors)

  6. Comparison of isokinetic muscle strength and muscle power by types of warm-up.

    Science.gov (United States)

    Sim, Young-Je; Byun, Yong-Hyun; Yoo, Jaehyun

    2015-05-01

    [Purpose] The purpose of this study was to clarify the influence of static stretching at warm-up on the isokinetic muscle torque (at 60°/sec) and muscle power (at 180°/sec) of the flexor muscle and extensor muscle of the knee joint. [Subjects and Methods] The subjects of this study were 10 healthy students with no medically specific findings. The warm-up group and warm-up with stretching group performed their respective warm-up prior to the isokinetic muscle torque evaluation of the knee joint. One-way ANOVA was performed by randomized block design for each variable. [Results] The results were as follows: First, the flexor peak torque and extensor peak torque of the knee joint tended to decrease at 60°/sec in the warm-up with stretching group compared with the control group and warm-up group, but without statistical significance. Second, extensor power at 180°/sec was also not statistically significant. However, it was found that flexor power increased significantly in the warm-up with stretching group at 180°/sec compared with the control group and warm-up group in which stretching was not performed. [Conclusion] Therefore, it is considered that in healthy adults, warm-up including two sets of stretching for 20 seconds per muscle group does not decrease muscle strength and muscle power.

  7. Reduksi Harmonisa Pada Uninterruptible Power Supply (UPS) Dengan Single Tuned Passive Filter

    OpenAIRE

    Nasution, Agus Almi

    2017-01-01

    Using non-linier load in Uninterruptible Power Supply (UPS) can cause harmonic distortion which will eventually have the effect on power quality. The research was designed as a single-turned passive filter to cope will harmonic distortion in UPS. In this phase, THDv, THDi, and IHDi were measured in UPS. MATLAB/Simulink was used for simulation of filter testing. After single-turned passive filter was installed, the third order of harmonic current decreased from 47,69% to 7,08% or reduced 40.61...

  8. Use of Reactor Pressure Vessel Surveillance Materials for Extended Life Evaluations Using Power and Test Reactor Irradiations

    International Nuclear Information System (INIS)

    Server, W.L.; Nanstad, R.K.; Odette, G.R.

    2012-01-01

    The most important component in assuring safety of the nuclear power plant is the reactor pressure (RPV). Surveillance programs have been designed to cover the licensed life of operating nuclear RPVs. The original surveillance programs were designed when the licensed life was 40 years. More than one-half of the operating nuclear plants in the USA have an extended license out to 60 years, and there are plans to continue to operate many plants out to 80 years. Therefore, the surveillance programs have had to be adjusted or enhanced to generate key data for 60 years, and now consideration must be given for 80 or more years. To generate the necessary data to assure safe operation out to these extended license lives, test reactor irradiations have been initiated with key RPV and model alloy steels, which include several steels irradiated in the current power reactor surveillance programs out to relatively high fluence levels. These data are crucial in understanding the radiation embrittlement mechanisms and to enable extrapolation of the irradiation effects on mechanical properties for these extended time periods. This paper describes the potential radiation embrittlement mechanisms and effects when assessing much longer operating times and higher neutron fluence levels. Potential methods for adjusting higher neutron flux test reactor data for use in predicting power reactor vessel conditions are discussed. (author)

  9. Prediction of motivational impairment: 12-month follow-up of the randomized-controlled trial on extended early intervention for first-episode psychosis.

    Science.gov (United States)

    Chang, W C; Kwong, V W Y; Chan, G H K; Jim, O T T; Lau, E S K; Hui, C L M; Chan, S K W; Lee, E H M; Chen, E Y H

    2017-03-01

    Amotivation is prevalent in first-episode psychosis (FEP) patients and is a major determinant of functional outcome. Prediction of amotivation in the early stage of psychosis, however, is under-studied. We aimed to prospectively examine predictors of amotivation in FEP patients in a randomized-controlled trial comparing a 1-year extension of early intervention (Extended EI, 3-year EI) with step-down psychiatric care (SC, 2-year EI). One hundred sixty Chinese patents were recruited from a specialized EI program for FEP in Hong Kong after they have completed this 2-year EI service, randomly allocated to Extended EI or SC, and followed up for 12 months. Assessments on premorbid adjustment, onset profiles, baseline symptom severity and treatment characteristics were conducted. Data analysis was based on 156 subjects who completed follow-up assessments. Amotivation at 12-month follow-up was associated with premorbid adjustment, allocated treatment condition, and levels of positive symptoms, disorganization, amotivation, diminished expression (DE) and depression at study intake. Hierarchical multiple regression analysis revealed that Extended EI and lower levels of DE independently predicted better outcome on 12-month amotivation. Our findings indicate a potentially critical therapeutic role of an extended specialized EI on alleviating motivational impairment in FEP patients. The longer-term effect of Extended EI on amotivation merits further investigation. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  10. Set up for simultaneous water desalination and power generation

    International Nuclear Information System (INIS)

    Hasan, S.W.; Mookhi, M.B.; Sadiq, M.A.; Hasan, Z.; Zaidi, S.I.; Shah, W.A.

    2010-01-01

    Instead of following the conventional fuel oriented power generation methods and dissipating its heat into environment, we evaporate saline water into steam and use its energy to generate power. Using this scheme would make sea water usable in power generation which at the moment is only being used for cooling purposes in the power plants. The steam used for generating electricity is eventually collected, condensed and used for potable purposes. The proposed scheme may be seen as Steam Power Generation with additional feature of desalination. We set up an experimental test bed in order to calculate the electric power available using this scheme. To ensure safety for human consumption, we also perform chemical tests on the desalinated water to see whether it is fit to be used for drinking and agricultural purposes. Our conclusions are based on actual experiments and laboratory tests; procedures outlined here may be used at larger scale for more in-depth analyses. We also highlight future extensions and modifications in this work. (author)

  11. Method for heating of the primary circuit of WWER electric power units at cold start-up

    International Nuclear Information System (INIS)

    Ivanov, I.N.; Dimitrov, B.D.; Korkinova, M.I.

    1982-01-01

    The method increases the heating rate and shorten the start-up time of the electric power units. It comprises a primary stopping of the reactor core heating and provides a forced circulation of the heat-carrier through the circulation cycles of the primary circuit. The thermal energy is supplied in one or several steam generators in the secondary circuit of an NPP operating unit. 1 cl., 3 figs

  12. Power decoding Reed-Solomon codes up to the Johnson radius

    DEFF Research Database (Denmark)

    Rosenkilde, Johan Sebastian Heesemann

    2018-01-01

    Power decoding, or "decoding using virtual interleaving" is a technique for decoding Reed-Solomon codes up to the Sudan radius. Since the method's inception, it has been an open question if it is possible to use this approach to decode up to the Johnson radius - the decoding radius of the Guruswami...

  13. Research on instability design method without occurring boiling transition for hyper ABWR plants of extended core power density

    International Nuclear Information System (INIS)

    Okamoto, T.; Hotta, A.; Ama, T.

    2008-01-01

    The hyper ABWR (Advanced Boiling Water Reactor) project aims to develop an advanced BWR concept that is competitive in the global market with both highly economic and safety features. Expecting plant construction within the coming ten years, a research program for substantiating the basic design of a high core power density ABWR was conducted. By inheriting the conventional ABWR design, it is possible to reduce construction costs. In order to achieve the rated core power of over 1650MWe which is almost equivalent to that of the EPR (European Pressurized Water Reactor), the core power density of ABWR will be up-rated by at least 25%. Three key subjects linked to this target were recognized. They are, (1) fuel design applicable to the high power density core, (2) improvement of the evaluation method for the coupled neutronic and thermal-hydraulic instability under a wider power-flow operating range, and (3) improvement of the steam separator performance under high quality conditions. In this paper, the second subject has been focused on. In the second subject, the uncertainty approach was introduced in the instability analysis where the best-estimate plant simulator was combined with a direct prediction of boiling transition by the sub-channel code. By employing the CSAU like method, a safety evaluation system that enables to include influences of uncertainties has been developed. Based on the correlation between the time margin for reaching the boiling transition under power oscillations and the decay ratio in the power-flow operation map, an automatic power oscillation suppressing system was designed. The set-point for activating suppression mechanisms (i.e. scram or SRI) could be determined based on this correlation. It was proposed that the present conservative acceptance criterion of the deterministic decay ratio can be replaced with a more rational one of the time margin with including uncertainties. (author)

  14. Long-term program up to fiscal 1993 of electric power source development

    International Nuclear Information System (INIS)

    Kawakami, Shin-ichi

    1984-01-01

    The long-term, ten years, program up to fiscal 1993 of electric power source development, determined by the Government aims at stable power supply and the expansion of utilization of petroleum-substitute energy. The annual growth in the gross national product (GNP) during the ten years was taken as about 4 %. So, the total electric power demand in fiscal 1993 is scheduled to be 731,000 million kwh, about 34 % up from 547,000 million kwh in fiscal 1983. The structure of electric power sources at the end of fiscal 1993 will be hydraulic 19.7 %, thermal 58.3 %, and nuclear 21.9 %. The development of electric power sources to be initiated in fiscal 1984 is hydraulic 500 MW, thermal 2,000 MW, and nuclear 6,000 MW. (Mori, K.)

  15. Evaluation of power commissioning of the Mochovce Unit 1 power level up to 100 % Nnom

    International Nuclear Information System (INIS)

    Sarvaic, I.; Mickolci, M.

    1998-01-01

    The document contains an evaluation of the power phase of power commissioning of the Mochovce Unit 1 in the phase up to the power level of 100 % N nom .In the document, the courses and results of tests in this phase of power commissioning are summarized, evaluation of the performance of important systems and equipment of the unit is carried out, and the compliance with Limits and Conditions in the course of the phase is assessed. On this basis, conclusions are drawn and recommendations for the unit to be ready for subsequent phases of the power commissioning. The evaluation was developed by the scientific management of the Mochovce commissioning providing an independent support for the operators for supervising the commissioning tasks from the point of nuclear safety

  16. Crude palm oil as fuel extender for diesel engines

    International Nuclear Information System (INIS)

    Mohamed M El-Awad; Fuad Abas; Mak Kian Sin

    2000-01-01

    In this work an investigation has been conducted into the use of Crude Palm Oil (CPO) as an extender fuel for diesel engines. Mixtures of CPO with normal diesel fuel (with a percentage of 25%, 50% and 75% CPO by volume) were used to fuel a stationary diesel engine and the engine performance variables, i.e., power output, fuel consumption, and exhaust-gas emission, were compared to those of normal diesel fuel. The results obtained, for a fixed throttle opening and variable speed, indicate that at high engine speeds, the engine performance with CP0/diesel mixtures with up to 50% CPO is comparable to that of diesel fuel. However, the results of the 75% CPO mixture showed a higher temperature and emission of CO and NO compared to the diesel fuel. At low engine speeds, the engine performance with CPO mixtures gave higher power output and lower emission of NO compared to that with diesel fuel, but showed higher specific fuel consumption and higher emission of CO. Based on these results, the study recommends that CPO can be used to extend diesel fuel in a mixture of up to 50% CPO by volume for an unmodified engine. (Author)

  17. Scale up, then power down

    International Nuclear Information System (INIS)

    Pichon, Max

    2011-01-01

    Full text: The University of Queensland has switched on what it says is Australia's largest solar photovoltaic installation, a 1.2MW system that spans 11 rooftops at the St Lucia campus. The UQ Solar Array, which effectively coats four buildings with more than 5,000 polycrystalline silicon solar panels, will generate about 1,850MWh a year. “During the day, the system will provide up to six per cent of the university's power requirements, reducing greenhouse gas emissions by approximately 1,650 tonnes of CO 2 -e per annum,”said Rodger Whitby, the GM of generation for renewables company Ingenero. It also underpins a number of cutting-edge research projects in diverse fields, according to Professor Paul Meredith, who oversaw the design and installation of the solar array. “A major objective of our array research program is to provide a clearer understanding of how to integrate megawatt- scale renewable energy sources into an urban grid,” said Professor Meredith, of the School of Mathematics and Physics and Global Change Institute. “Mid-size, commercial-scale renewable power generating systems like UQ's will become increasingly common in urban and remote areas. Addressing the engineering issues around how these systems can feed into and integrate with the grid is essential so that people can really understand and calculate their value as we transition to lower-emission forms of energy.” Electricity retailer Energex contributed $90,000 to the research project through state-of-the- art equipment to allow high-quality monitoring and analysis of the power feed. Another key research project addresses one of the most common criticisms of solar power: that it cannot replace baseload grid power. Through a partnership with Brisbane electricity storage technology company RedFlow, a 200kW battery bank will be connected to a 339kW section of the solar array. “The RedFlow system uses next-generation zinc bromine batteries,” Professor Meredith said.

  18. Fission-gas release in fuel performing to extended burnups in Ontario Hydro nuclear generating stations

    International Nuclear Information System (INIS)

    Floyd, M.R.; Novak, J.; Truant, P.T.

    1992-06-01

    The average discharge burnup of CANDU fuel is about 200 MWh/kgU. A significant number of 37-element bundles have achieved burnups in excess of 400 MWh/kgU. Some of these bundles have experienced failures related to their extended operation. To date, hot-cell examinations have been performed on fuel elements from nine 37-element bundles irradiated in Bruce NGS-A that have burnups in the range of 300-800 MWh/kgU. 1 Most of these have declining power histories from peak powers of up to 59 kW/m. Fission-gas releases of up to 26% have been observed and exhibit a strong dependence on fuel power. This obscures any dependence on burnup. The extent of fission-gas release at extended burnups was not predicted by low-burnup code extrapolations. This is attributed primarily to a reduction in fuel thermal conductivity which results in elevated operating temperatures. Reduced conductivity is due, at least in part, to the buildup of fission products in the fuel matrix. Some evidence of hyperstoichiometry exists, although this needs to be further investigated along with any possible relation to CANLUB graphite coating behaviour and sheath oxidation. Residual tensile sheath strains of up to 2% have been observed and can be correlated with fuel power/fission-gas release. SCC 2 -related defects have been observed in the sheath and endcaps of elements from bundles experiencing declining power histories to burnups in excess of 500 MWh/kgU. This indicates that the current recommended burnup limit of 450 MWh/kgU is justified. SCC-related defects have also been observed in ramped bundles having burnups < 450 MWh/kgU. Hence, additional guidelines are in place for power ramping extended-burnup fuel

  19. Range extender module. Enabler for electric mobility; Range-Extender-Modul. Wegbereiter fuer elektrische Mobilitaet

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, Robert; Fraidl, Guenter Karl; Hubmann, Christian; Kapus, Paul Ernst; Kunzemann, Ralf; Sifferlinger, Bernhard; Beste, Frank [AVL List GmbH, Graz (Austria)

    2009-10-15

    The Range Extender as an auxiliary power supply for extended driving ranges is of significant importance in achieving a high level of customer acceptance for electric vehicles. The AVL concept is optimized for electric power generation in single-point operation and allows a compactly integrated, cost-efficient and weight-efficient module design. The internal combustion engine requirements of the Pure Range Extender from AVL permit not only the use of simplified four-stroke concepts but also the application of emission-optimized and fuel consumption-optimized two-stroke and rotary piston engines. (orig.)

  20. Extended performance electric propulsion power processor design study. Volume 2: Technical summary

    Science.gov (United States)

    Biess, J. J.; Inouye, L. Y.; Schoenfeld, A. D.

    1977-01-01

    Electric propulsion power processor technology has processed during the past decade to the point that it is considered ready for application. Several power processor design concepts were evaluated and compared. Emphasis was placed on a 30 cm ion thruster power processor with a beam power rating supply of 2.2KW to 10KW for the main propulsion power stage. Extension in power processor performance were defined and were designed in sufficient detail to determine efficiency, component weight, part count, reliability and thermal control. A detail design was performed on a microprocessor as the thyristor power processor controller. A reliability analysis was performed to evaluate the effect of the control electronics redesign. Preliminary electrical design, mechanical design and thermal analysis were performed on a 6KW power transformer for the beam supply. Bi-Mod mechanical, structural and thermal control configurations were evaluated for the power processor and preliminary estimates of mechanical weight were determined.

  1. Extended teamwork: team performance in highly automated nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Skjerve, Ann Britt; Strand, Stine; Skraaning, Gyrd Jr.

    2004-07-01

    Nuclear power plant (NPP) operation is in essence a teamwork task. The central control-room (CCR) operators are required to co-operate to achieve the operational goals, and they further depend on the assistance of the field operators and, at least in modern plants, on the assistance of the high-level automatic system. Future NPPs (e.g., advanced reactors) are foreseen to contain substantially higher automation levels, reduced staffing, and redefined roles of the remaining staff, as compared to the present situation. This paper suggests that in future plants, in which the autonomy and authority of the automatic system and of the field operators are increased, the transactions between the CCR operators and automatic system/field operators might most efficiently be conceptualized within the framework of co-operation, and thus teamwork. This framework has typically been restricted to conceptualizations of the transactions between the CCR operators, but in future settings, co-ordination, communication and mutual support between the CCR operators and the field operators/automatic system may be of increased importance for sustaining plant safety, as compared to the present situation. The paper further argues that human-system interfaces in future NPPs should be designed to support the activities of the extended team consisting of the CCR operators, the field operators, and the automatic system. The paper outlines an exploratory study aimed at generating ideas on how extended teamwork quality may be promoted. The study is currently foreseen to comprise two exemplary design solutions: a state-of-the art screen-based control-room (baseline condition) and a possible future control-room in which the activities of the field operators and the automatic system are explicitly represented on the human-system interface, where the authority and autonomy of these are increased, and the staffing level reduced, as compared to the baseline condition. The study will explore extended

  2. Extended teamwork: team performance in highly automated nuclear power plants

    International Nuclear Information System (INIS)

    Skjerve, Ann Britt; Strand, Stine; Skraaning, Gyrd Jr.

    2004-01-01

    Nuclear power plant (NPP) operation is in essence a teamwork task. The central control-room (CCR) operators are required to co-operate to achieve the operational goals, and they further depend on the assistance of the field operators and, at least in modern plants, on the assistance of the high-level automatic system. Future NPPs (e.g., advanced reactors) are foreseen to contain substantially higher automation levels, reduced staffing, and redefined roles of the remaining staff, as compared to the present situation. This paper suggests that in future plants, in which the autonomy and authority of the automatic system and of the field operators are increased, the transactions between the CCR operators and automatic system/field operators might most efficiently be conceptualized within the framework of co-operation, and thus teamwork. This framework has typically been restricted to conceptualizations of the transactions between the CCR operators, but in future settings, co-ordination, communication and mutual support between the CCR operators and the field operators/automatic system may be of increased importance for sustaining plant safety, as compared to the present situation. The paper further argues that human-system interfaces in future NPPs should be designed to support the activities of the extended team consisting of the CCR operators, the field operators, and the automatic system. The paper outlines an exploratory study aimed at generating ideas on how extended teamwork quality may be promoted. The study is currently foreseen to comprise two exemplary design solutions: a state-of-the art screen-based control-room (baseline condition) and a possible future control-room in which the activities of the field operators and the automatic system are explicitly represented on the human-system interface, where the authority and autonomy of these are increased, and the staffing level reduced, as compared to the baseline condition. The study will explore extended

  3. The extended Betz-Lanchester limit

    Energy Technology Data Exchange (ETDEWEB)

    Cuerva, A.; Sanz-Andres, A. [Universidad Politecnica de Madrid (Spain). IDR/UPM, E.T.S.I.

    2005-04-01

    A proposal for an extended formulation of the power coefficient of a wind turbine is presented. This new formulation is a generalization of the Betz-Lanchester expression for the power coefficient as function of the axial deceleration of the wind speed provoked by the wind turbine in operation. The extended power coefficient takes into account the benefits of the power produced and the cost associated to the production of this energy. By the simple model proposed is evidenced that the purely energetic optimum operation condition giving rise to the Betz-Lanchester limit (maximum energy produced) does not coincide with the global optimum operational condition (maximum benefit generated) if cost of energy and degradation of the wind turbine during operation is considered. The new extended power coefficient is a general parameter useful to define global optimum operation conditions for wind turbines, considering not only the energy production but also the maintenance cost and the economic cost associated to the life reduction of the machine. (author)

  4. Extending Femtosecond Filamentation of High Power Laser Propagating in the Atmosphere

    Science.gov (United States)

    Eisenmann, Shmuel; Sivan, Yonatan; Fibich, Gadi; Zigler, Arie

    2008-06-01

    We show experimentally for ultrashort laser pulses propagating in air, that the filamentation distance of intense laser pulses in the atmosphere can be extended and controlled with a simple double-lens setup. Using this method we were able to achieve a 20-fold delay of the filamentation distance of non-chirped 120 fs pulses propagating in air, from 16 m to 330 m. At 330 m, the collapsing pulse is sufficiently powerful to create plasma filaments. We also show that the scatter of the filaments at 330 m can be significantly reduced by tilting the second lens. We derive a simple formula for the filamentation distance, and confirm its agreement with the experimental results. We also observe that delaying the onset of filamentation increases the filament length. To the best of our knowledge, this is the longest distance reported in the literature at which plasma filaments were created and controlled. Finally, we show that the peak power at the onset of collapse is significantly higher with the double-lens setup, compared with the standard negative chirping approach.

  5. An estimation of reactor thermal power uncertainty using UFM-based feedwater flow rate in nuclear power plants

    International Nuclear Information System (INIS)

    Byung Ryul Jung; Ho Cheol Jang; Byung Jin Lee; Se Jin Baik; Woo Hyun Jang

    2005-01-01

    Most of Pressurized Water Reactors (PWRs) utilize the venturi meters (VMs) to measure the feedwater (FW) flow rate to the steam generator in the calorimetric measurement, which is used in the reactor thermal power (RTP) estimation. However, measurement drifts have been experienced due to some anomalies on the venturi meter (generally called the venturi meter fouling). The VM's fouling tends to increase the measured pressure drop across the meter, which results in indication of increased feedwater flow rate. Finally, the reactor thermal power is overestimated and the actual reactor power is to be reduced to remain within the regulatory limits. To overcome this VM's fouling problem, the Ultrasonic Flow Meter (UFM) has recently been gaining attention in the measurement of the feedwater flow rate. This paper presents the applicability of a UFM based feedwater flow rate in the estimation of reactor thermal power uncertainty. The FW and RTP uncertainties are compared in terms of sensitivities between the VM- and UFM-based feedwater flow rates. Data from typical Optimized Power Reactor 1000 (OPR1000) plants are used to estimate the uncertainty. (authors)

  6. Comparison of numerical and experimental results on flow rate and friction losses in water outflow from extended pipelines

    International Nuclear Information System (INIS)

    Makukhin, A.A.; Fisenko, V.V.; Kolykhanov, V.N.

    1985-01-01

    Results are presented of numerical calculation and experimental determinaion of the flow rate and friction losses during boiling-up water flow motion in extended pipelines at critical outflow regime with account of compressibility of heat-transferring medium. The difference of the calculation model proposed is in the fact that the presence of a finite length pipeline portion is implied where the Mach number (M) remains equal to 1 at a continuously varying flow rate and the sound velocity varying from its thermodynamical equilibrium value inside the channel to the non-equilibrium one at the exit. At that the deceleration pressure along this portion remains constant, and the M=1 condition is maintained automatically due to a constant flow rate. Analysis of numerical experiment has shown that the new scheme of heat transfer by critical two-phase flow is more efficient than that by one-phase flow within the 0.5 to 8 MPa range of initial pressures at a 0-50 K subcooling as a result of a decrease in the head of transfering pumps and a reduction in the pipeline pressure. Experiments carried out show good agreement with the calclation data

  7. Mortality in an extended follow-up of British coal workers

    International Nuclear Information System (INIS)

    MacCalman, L; Miller, B G

    2009-01-01

    The Pneumoconiosis Field Research (PFR) programme was established in the 1950s, to evaluate effects of coal mining exposures on the health and mortality of British coal workers. Surveys of working miners were carried out at 5-yearly intervals, initially in 24 collieries but later concentrating on 10, collecting detailed work histories and health information for each recruit. Here we report on cause-specific mortality in a cohort of almost 18,000 men from 10 British collieries, followed up for periods up to 47 years, yielding over 516,000 life-years of follow-up. External analyses compared cause-specific death rates in the cohort to those of the population of the regions in which the collieries were situated, using Standardised Mortality Ratios (SMRs). The causes investigated included lung cancer, stomach cancer, non-malignant respiratory disorders and cardiovascular disorders. SMRs showed evidence of an initial healthy worker effect diminishing over time. Several causes, including non-malignant respiratory disease and lung cancer, showed a significant deficit of mortality at the start of the study period with an excess in the latter part of the follow-up period. In these results, effects of working conditions are likely to be confounded with smoking habits. Overall, we believe our results may be generalised to the British coal industry since nationalisation.

  8. Deepening structural reform, and speeding up self-reliant nuclear power development

    International Nuclear Information System (INIS)

    Wang Binghua

    2010-01-01

    Combining the implementation practices of the strategy on self-reliant development of the third generation nuclear power plant, the paper set forth that speeding up self-reliant nuclear power development has strategic significance to the national economy and the people's livelihood, which need further deepening structural reform and nuclear power structural reform with an aim to enhance the international competitiveness of China's nuclear industry. (author)

  9. Surveillance strategy for an extended operating cycle in commercial nuclear reactors

    International Nuclear Information System (INIS)

    McHenry, R.S.; Moore, T.J.; Maurer, J.H.; Todreas, N.E.

    1997-01-01

    The impetus for improved economic performance of commercial nuclear power plants can be partially satisfied by increasing plant capacity factors through operating cycle extension. One aspect of an operating cycle extension effort is the modification of plant surveillance programs to complete required regulatory and investment protection surveillance activities within the extended planned outage schedule. The goal of this paper is to introduce a general strategy for existing power plants to transition their surveillance programs to an extended operating cycle up to 48 months in length, and to test the feasibility of this strategy through the complete analysis of the surveillance programs at operating BWR and PWR case study plants. The reconciliation of surveillances at these plants demonstrates that surveillance performance will not preclude 48 month operating cycles. Those surveillance activities that could not be resolved to an extended cycle are identified for further study. Finally, a number of general issues are presented that should be considered before implementing a cycle extension effort

  10. Surveillance strategy for an extended operating cycle in commercial nuclear reactors

    International Nuclear Information System (INIS)

    McHenry, R.S.; Moore, T.J.; Maurer, J.H.; Todreas, N.E.

    1997-01-01

    The impetus for improved economic performance of commercial nuclear power plants can be partially satisfied by increasing plant capacity factors through operating cycle extension. One aspect of an operating cycle extension effort is the modification of plant surveillance programs to complete required regulatory and investment protection surveillance activities within the extended planned outage schedule. The goal is to introduce a general strategy for existing power plants to transition their surveillance programs to an extended operating cycle up to 48 months in length, and to test the feasibility of this strategy through the complete analysis of the surveillance programs at operating BWR and PWR case study plants. The reconciliation of surveillances at these plants demonstrates that surveillance performance will not preclude 48 month operating cycles. Those surveillance activities that could not be resolved to an extended cycle are identified for further study. Finally, a number of general issues are presented that should be considered before implementing a cycle extension effort

  11. Power flow controller with a fractionally rated back-to-back converter

    Science.gov (United States)

    Divan, Deepakraj M.; Kandula, Rajendra Prasad; Prasai, Anish

    2016-03-08

    A power flow controller with a fractionally rated back-to-back (BTB) converter is provided. The power flow controller provide dynamic control of both active and reactive power of a power system. The power flow controller inserts a voltage with controllable magnitude and phase between two AC sources at the same frequency; thereby effecting control of active and reactive power flows between the two AC sources. A transformer may be augmented with a fractionally rated bi-directional Back to Back (BTB) converter. The fractionally rated BTB converter comprises a transformer side converter (TSC), a direct-current (DC) link, and a line side converter (LSC). By controlling the switches of the BTB converter, the effective phase angle between the two AC source voltages may be regulated, and the amplitude of the voltage inserted by the power flow controller may be adjusted with respect to the AC source voltages.

  12. Flare-up rate of single-visit endodontics.

    Science.gov (United States)

    Trope, M

    1991-01-01

    The purpose of the study was to compare the flare-up rate for single-visit endodontics among teeth without radiographic or clinical signs of apical periodontitis, those with radiographic or clinical signs of apical periodontitis not previously root-treated, and those with apical periodontitis where retreatment was performed. All teeth were instrumented to a predetermined minimum size with a 0.5 per cent solution of sodium hypochlorite being used as the irrigant. The root canal was obturated without regard to the presence or absence of symptoms or diagnosis of the apical condition. The patients were given written post-operative instructions and a prescription for 600 mg ibuprofen to be taken if mild to moderate pain developed. If severe pain and/or swelling developed, the patient was instructed to telephone immediately and was considered to have had a flare-up. Teeth without signs of apical periodontitis did not have any flare-ups. One flare-up occurred in 69 teeth with signs of apical periodontitis not previously root-treated. The majority of the flare-ups (3 of 22 teeth) occurred in teeth with signs of apical periodontitis requiring retreatment.

  13. Powering the Future Data Centre

    DEFF Research Database (Denmark)

    Zhang, Zhe

    2010-01-01

    of the characteristics of these two power sources: long warm-up stage and low dynamics for fuel cell, and variable terminal voltage for supercapacitors. The motivation for this project was to find ways which can overcome those limitations to integrate fuel cells and supercapcitors to the system with high efficiency......The extended run Uninterruptible Power Supply system (UPSs) which powered by fuel cells and supercapcitors, is a promising solution for future data centre to obtain environmentfriendly energy efficient and cost effective. There are many challenges in power electronic interface circuits, because......: • Optimized design method for dual active bridge (DAB) converter and its derived circuits; • A novel hybrid dc-dc converter and its corresponding optimal design method are proposed; • An improved dual input current-fed DC-DC converter with bidirectional power conversion ability is investigated; • Extend...

  14. Nuclear Power Learning and Deployment Rates; Disruption and Global Benefits Forgone

    OpenAIRE

    Peter A. Lang

    2017-01-01

    This paper presents evidence of the disruption of a transition from fossil fuels to nuclear power, and finds the benefits forgone as a consequence are substantial. Learning rates are presented for nuclear power in seven countries, comprising 58% of all power reactors ever built globally. Learning rates and deployment rates changed in the late-1960s and 1970s from rapidly falling costs and accelerating deployment to rapidly rising costs and stalled deployment. Historical nuclear global capacit...

  15. Does string theory lead to extended inflation?

    Science.gov (United States)

    Campbell, Bruce A.; Linde, Andrei; Olive, Keith A.

    1991-05-01

    We consider the relationship between string theory and currently proposed models of extended inflation. In doing so, we discuss the conformal actions in string theory and in Jordan-Brans-Dicke gravity. We show explicitly the equivalence of pictures in which either gauge or gravitational couplings are changing with time. We demonstrate that the existence of the dilation in string theory does not naturally lead to extended inflation as currently discussed. We also discuss the resolution of the graceful exit problem of old inflation in Einstein gravity using either power-law inflation, or exponential inflation with a changing bubble formation rate. On leave of absence from School of Physics and Astronomy, University of Minnesota, Minneapolis, MN 55455, USA.

  16. Estimation of build up of dose rate on U3O8 product drum

    International Nuclear Information System (INIS)

    Pandey, J.P.N.; Shinde, A.M.; Deshpande, M.D.

    2008-01-01

    In fuel reprocessing plant, plutonium oxide and uranium oxide (U 3 O 8 ) are products. Approximately 180 kg U 3 O 8 is filled in SS drum and sealed firmly before storage. In PHWR natural uranium (UO 2 ) is used as fuel. In natural uranium, thorium-232 is present as an impurity at few tens of ppm level. During irradiation in power reactors, due to nuclear reaction formation of 232 U from 232 Th takes place. Natural decay of 232 U leads to the formation of 208 Tl. As time passes, there is buildup of 208 Tl and hence increase in dose rate on the drum containing U 3 O 8 . It is essential to estimate the buildup of dose rate considering the external radiological hazards involved during U 3 O 8 drum handling, transportation and fuel fabrication. This paper describes the calculation of dose rate on drum in future years using MCNP code. For dose rate calculation decay of fission product activity which remains as contamination in product and build up of '2 08 Tl from 232 U is considered. Some measured values of dose rate on U 3 O 8 drum are given for the comparisons with estimated dose rate based on MCNP code. (author)

  17. Energy, Electricity and Nuclear Power Estimates for the Period up to 2050. 2011 Edition

    International Nuclear Information System (INIS)

    2011-01-01

    Reference Data Series No. 1 (RDS-1) is an annual publication - currently in its thirty first edition - containing estimates of energy, electricity and nuclear power trends up to the year 2050. RDS-1 starts with a summary of the situation of nuclear power in IAEA Member States as of the end of 2010. The data on nuclear power presented in Tables 1 and 2 are based on actual statistical data collected by the IAEA's power Reactor Information System (pRIS). However, energy and electricity data for 2010 are estimated, as the latest information available from the united Nations Department of Economic and Social Affairs is for 2008 only. population data originate from the world population prospects (2010 revision), published by the population Division of the united Nations Department of Economic and Social Affairs. The 2010 values again are estimates. As in previous editions, projections of future energy and electricity demand and the role of nuclear power are presented as low and high estimates encompassing the inherent uncertainties involved in projecting trends. The RDS-1 estimates should be viewed as very general growth trends whose validity must be constantly subjected to critical review. Beginning with the 30th edition of this publication, however, the end-point of the estimates was extended up to the year 2050 (instead of 2030). Looking beyond 2030 has been prompted by the interest expressed by numerous Member States currently without nuclear power in adding nuclear energy to their future national energy supply mixes. Given the extensive lead times in planning and implementing nuclear power programmes, a fair share of these are likely to result in actual plant commissioning and grid connection after 2030. Many international, national and private organizations routinely engage in energy demand and supply projections, including nuclear power. These projections are based on a multitude of different assumptions and aggregating procedures, which make a straightforward

  18. Health status and follow-up of the Chernobyl Nuclear Power Plant accident liquidators in Latvia

    International Nuclear Information System (INIS)

    Curbakova, E.; Dzerve, B.; Eglite, M.; Frickausa, I.; Zvagule, T.

    1996-01-01

    The accident at the Nuclear Power Plant in Chernobyl create a new problem for health professionals in Latvia due to the fact that 6475 inhabitants (mainly healthy and men of reproductive age) of Latvia took part in clear-up works in Chernobyl within the period 1986-1991. Chernobyl clear-up workers were exposed γ-radiation and they also incorporated radionuclides. The doses documented for the clear-up workers are variable; they are estimated to be between 0.01-0.5 Gy although the specialists working on the precision of received doses think that they could be even 2 or 3 times higher. The aim of this work is to evaluate the health status of liquidators investigating them on a long-term basis: to create the correct system of health status evaluation of Chernobyl clear-up workers, to improve the register of Chernobyl clear-up workers and of their children, to analyze the data about the incidence of different diseases and mortality gained from follow-ups, to evaluate health status and clinical picture within the period of time, to work out and use adequate methods of treatment. Chernobyl clear-up workers more often than the control group suffer from diseases of the nervous, the endocrine and the metabolic and immune system. They also have higher rate of incidence for diseases of digestive and respiratory system and for diseases of bones, muscles and connective tissue higher rates of accidents and suicides. Now, ten years after the accident there are Chernobyl clear-up workers who are chronically ill and their health status is expected to be worse in the next few years. Regular follow-up and medical examination of Chernobyl clear-up workers and their children should be carried out every year. Regular rehabilitation of Chernobyl clear-up workers should be provided by the government

  19. Health status and follow-up of the Chernobyl Nuclear Power Plant accident liquidators in Latvia

    Energy Technology Data Exchange (ETDEWEB)

    Curbakova, E; Dzerve, B; Eglite, M; Frickausa, I; Zvagule, T [Centre of Occupational and Radiological Medicine of P. Stradins State clinical Hospital, Riga (Latvia)

    1996-07-01

    The accident at the Nuclear Power Plant in Chernobyl create a new problem for health professionals in Latvia due to the fact that 6475 inhabitants (mainly healthy and men of reproductive age) of Latvia took part in clear-up works in Chernobyl within the period 1986-1991. Chernobyl clear-up workers were exposed {gamma}-radiation and they also incorporated radionuclides. The doses documented for the clear-up workers are variable; they are estimated to be between 0.01-0.5 Gy although the specialists working on the precision of received doses think that they could be even 2 or 3 times higher. The aim of this work is to evaluate the health status of liquidators investigating them on a long-term basis: to create the correct system of health status evaluation of Chernobyl clear-up workers, to improve the register of Chernobyl clear-up workers and of their children, to analyze the data about the incidence of different diseases and mortality gained from follow-ups, to evaluate health status and clinical picture within the period of time, to work out and use adequate methods of treatment. Chernobyl clear-up workers more often than the control group suffer from diseases of the nervous, the endocrine and the metabolic and immune system. They also have higher rate of incidence for diseases of digestive and respiratory system and for diseases of bones, muscles and connective tissue higher rates of accidents and suicides. Now, ten years after the accident there are Chernobyl clear-up workers who are chronically ill and their health status is expected to be worse in the next few years. Regular follow-up and medical examination of Chernobyl clear-up workers and their children should be carried out every year. Regular rehabilitation of Chernobyl clear-up workers should be provided by the government.

  20. Coal-Fired Power Plant Heat Rate Reductions

    Science.gov (United States)

    View a report that identifies systems and equipment in coal-fired power plants where efficiency improvements can be realized, and provides estimates of the resulting net plant heat rate reductions and costs for implementation.

  1. Smart pile-up consideration for evaluation of high count rate EDS spectra

    International Nuclear Information System (INIS)

    Eggert, F; Anderhalt, R; Nicolosi, J; Elam, T

    2012-01-01

    This work describes a new pile-up consideration for the very high count rate spectra which are possible to acquire with silicon drift detector (SDD) technology. Pile-up effects are the major and still remaining challenge with the use of SDD for EDS in scanning electron microscopes (SEM) with ultra thin windows for soft X-ray detection. The ability to increase the count rates up to a factor of 100 compared with conventional Si(Li) detectors, comes with the problem that the pile-up recognition (pile-up rejection) in pulse processors is not able to improve by the same order of magnitude, just only with a factor of about 3. Therefore, it is common that spectra will show significant pile-up effects if count rates of more than 10000 counts per second (10 kcps) are used. These false counts affect both automatic qualitative analysis and quantitative evaluation of the spectra. The new idea is to use additional inputs for pile-up calculation to shift the applicability towards very high count rates of up to 200 kcps and more, which can be easily acquired with the SDD. The additional input is the 'known' (estimated) background distribution, calculated iteratively during all automated qualitative or quantitative evaluations. This additional knowledge gives the opportunity for self adjustment of the pile-up calculation parameters and avoids over-corrections which challenge the evaluation as well as the pile-up artefacts themselves. With the proposed method the pile-up correction is no longer a 'correction' but an integral part of all spectra evaluation steps. Examples for the application are given with evaluation of very high count rate spectra.

  2. A neutron survey meter with sensitivity extended up to 400 MeV

    International Nuclear Information System (INIS)

    Birattari, C.; Silari, M.

    1992-01-01

    The well-known Andersson-Braun rem counter is widely employed for radiation protection purposes, but its efficiency shows a marked decrease for neutron energies above about 10 MeV. Since the availability of a survey meter with a good sensitivity to higher energies can be very useful, for instance, at many particle accelerator facilities, a neutron monitor with a response function extended up to 400 MeV has been achieved by modifying the structure of the moderator-attenuator of a commercial instrument. The first experimental tests carried out to verify the response of the new monitor both to low and high energy neutrons are reported. A comparison with the response function of three conventional commercial rem counters is presented. (author)

  3. Optimal power allocation of a sensor node under different rate constraints

    KAUST Repository

    Ayala Solares, Jose Roberto; Rezki, Zouheir; Alouini, Mohamed-Slim

    2012-01-01

    The optimal transmit power of a sensor node while satisfying different rate constraints is derived. First, an optimization problem with an instantaneous transmission rate constraint is addressed. Next, the optimal power is analyzed, but now

  4. Some power uprate issues in nuclear power plants

    International Nuclear Information System (INIS)

    Tipping, Philip

    2008-01-01

    Issues and themes concerned with nuclear power plant uprating are examined. Attention is brought to the fact that many candidate nuclear power plants for uprating have anyway been operated below their rated power for a significant part of their operating life. The key issues remain safety and reliability in operation at all times, irrespective of the nuclear power plant's chronological or design age or power rating. The effects of power uprates are discussed in terms of material aspects and expected demands on the systems, structures and components. The impact on operation and maintenance methods is indicated in terms of changes to the ageing surveillance programmes. Attention is brought to the necessity checking or revising operator actions after power up-rating has been implemented

  5. ECRH experiments in an extended power regime on the large helical device

    International Nuclear Information System (INIS)

    Shimozuma, T.; Kubo, S.; Idei, H.; LHD Experimental Group

    2003-01-01

    The Large Helical Device (LHD) is the largest Heliotron-type device (L 2, m = 10) The magnetic field for plasma confinement is produced by a pair of helical coils and three pairs of poloidal coils. The magnetic configuration can be adjusted by these external coils. These coils are all superconducting coils and enable steady state operation. The major and the minor radii of the produced plasmas are typically 3.6 m and 0.6 m, respectively. Plasma experiments in LHD have been proceeded since 1998. A lot of diagnostic devices have been installed to make precise plasma measurement spatially and temporally. Heating power reaches 9 MW for Neutral Beam Injection (NBI), 2.7 MW for Ion Cyclotron Range of Frequency heating (ICRF) and 1.8 MW for Electron Cyclotron Resonance Heating (ECRH). Achieved plasma parameters have been improved in each experimental campaign. In the latest experimental campaign, some improvements of the ECRH system led to interesting results related to the electron physics, such as the attainment of over 10 keV electron temperature and the improvement of core confinement in low collisionality regime. This paper reports the improvement of the ECRH system in the latest campaign and some experimental results related to the local electron heating in an extended power regime. In the Section 2 we will describe the improvements of the ECRH system for experiments in higher power region. Using this system, localized ECRH with high power density was performed. Experimental results obtained will be given in Section 3. The final section will be devoted to the following conclusions. In the latest experimental campaign, seven gyrotron systems were operable. One transmission line which was evacuated in whole system was installed in addition to the six existed 88.9 mm lines in atmospheric pressure. This line allows to transmit over 500 kW power. Flexible experiments could be performed by the inward shift of a scanning range of the existed antennas and by an installation

  6. Start-up test of Fukushima Daini Nuclear Power Station Unit No.3

    International Nuclear Information System (INIS)

    Inomata, Toshio; Umezu, Akira; Kajikawa, Makoto; Koibuchi, Hiroshi; Netsu, Nobuhiko.

    1986-01-01

    In Unit 3 of the Fukushima Nuclear Power Station II (daini), a BWR power plant of output 1,100 MW, commercial operation was started in June 1985. Its start-up test was finished successfully in about nine months. That is, new equipments introduced were demonstration tested. Though the items of testing are increased, the start-up test took short time, resulting in construction period only 54.7 months of the Unit 3, the shortest in the world. During the test, there was no scramming other than the planned. Described are the following: an outline of the Unit 3, the items of its improvement and standardization, including the new equipments, preparations for the start-up test, the start-up test and its evaluation. (Mori, K.)

  7. Cryopreservation of Boer goat spermatozoa: Comparison of two freezing extenders based on post-thaw sperm quality and fertility rates

    Directory of Open Access Journals (Sweden)

    Fitra Aji Pamungkas

    2014-06-01

    Full Text Available Boer goat have recently been popularly used for cross breeding with local goats. However, it is currently considered a breed at very limited number with relatively high prices . In this context, the cryopreservation of spermatozoa is important because it could be conserved for a very long period of time. Egg yolk extenders are most commonly used for cryopreservation of goat sperm. The aim of this study was to compare the ability of two extenders to maintain sperm viability after cryopreservation. Semen from three male Boer goat aged about 2-3 years old was collected using artificial vagina and frozen with Tris and Triladyl extender. The results showed that percentage of motility, viability and membrane integrity of spermatozoa with Tris and Triladyl extenders at every stage of cryopreservation showed not significantly difference (P>0.05, except the percentage of sperm motility post thawing of Triladyl was higher than Tris extender (52.00±4.47% vs 47.50±2.74%, P<0.05. Cryopreserved semen in Tris extender provided the same fertility rates after cervical insemination compared to Triladyl (62.50% vs 60.00%. In conclusion, the Tris extender has the same capabilities to Triladyl in cryopreservation of Boer goat spermatozoa as to maintain sperm quality and fertility rates.

  8. Start-up neutral-beam power supply system for MFTF

    International Nuclear Information System (INIS)

    Mooney, L.J.

    1979-01-01

    This paper describes some of the design features and considerations of the MFTF start-up neutral-beam power supplies. In particular, we emphasize features of the system that will ensure MFTF compatibility and achieve the required reliability/availability for the MFTF to be successful

  9. Mortality in an extended follow-up of British coal workers

    Energy Technology Data Exchange (ETDEWEB)

    MacCalman, L.; Miller, B.G. [Institute of Occupational Medicine, Edinburgh (United Kingdom)

    2009-07-01

    The Pneumoconiosis Field Research (PFR) programme was established in the 1950s, to evaluate effects of coal mining exposures on the health and mortality of British coal workers. Surveys of working miners were carried out at 5-yearly intervals, initially in 24 collieries but later concentrating on 10, collecting detailed work histories and health information for each recruit. Here we report on cause-specific mortality in a cohort of almost 18,000 men from 10 British collieries, followed up for periods up to 47 years, yielding over 516,000 life-years of follow-up. External analyses compared cause-specific death rates in the cohort to those of the population of the regions in which the collieries were situated, using Standardised Mortality Ratios (SMRs). The causes investigated included lung cancer, stomach cancer, non-malignant respiratory disorders and cardiovascular disorders. SMRs showed evidence of an initial healthy worker effect diminishing over time. Several causes, including non-malignant respiratory disease and lung cancer, showed a significant deficit of mortality at the start of the study period with an excess in the latter part of the follow-up period. In these results, effects of working conditions are likely to be confounded with smoking habits. Overall, we believe our results may be generalised to the British coal industry since nationalisation. 11 refs., 4 figs., 1 tab.

  10. Modular high-voltage bias generator powered by dual-looped self-adaptive wireless power transmission.

    Science.gov (United States)

    Xie, Kai; Huang, An-Feng; Li, Xiao-Ping; Guo, Shi-Zhong; Zhang, Han-Lu

    2015-04-01

    We proposed a modular high-voltage (HV) bias generator powered by a novel transmitter-sharing inductive coupled wireless power transmission technology, aimed to extend the generator's flexibility and configurability. To solve the problems caused through an uncertain number of modules, a dual-looped self-adaptive control method is proposed that is capable of tracking resonance frequency while maintaining a relatively stable induction voltage for each HV module. The method combines a phase-locked loop and a current feedback loop, which ensures an accurate resonance state and a relatively constant boost ratio for each module, simplifying the architecture of the boost stage and improving the total efficiency. The prototype was built and tested. The input voltage drop of each module is less than 14% if the module number varies from 3 to 10; resonance tracking is completed within 60 ms. The efficiency of the coupling structure reaches up to 95%, whereas the total efficiency approaches 73% for a rated output. Furthermore, this technology can be used in various multi-load wireless power supply applications.

  11. Applications: REP-rate pulse power technology

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Research on the following topics is discussed: (1) REP-rate pulse power technology, (2) RTF-I, 300-J, 100-pps test facility experiments, (3) transformer development, (4) reactor system studies, (5) general conceptual design, (6) economic considerations, (7) specific reactor designs, (8) low-current density diode physics studies, and (9) plasma injected, microsecond, E-beam diodes

  12. Power penalties for multi-level PAM modulation formats at arbitrary bit error rates

    Science.gov (United States)

    Kaliteevskiy, Nikolay A.; Wood, William A.; Downie, John D.; Hurley, Jason; Sterlingov, Petr

    2016-03-01

    There is considerable interest in combining multi-level pulsed amplitude modulation formats (PAM-L) and forward error correction (FEC) in next-generation, short-range optical communications links for increased capacity. In this paper we derive new formulas for the optical power penalties due to modulation format complexity relative to PAM-2 and due to inter-symbol interference (ISI). We show that these penalties depend on the required system bit-error rate (BER) and that the conventional formulas overestimate link penalties. Our corrections to the standard formulas are very small at conventional BER levels (typically 1×10-12) but become significant at the higher BER levels enabled by FEC technology, especially for signal distortions due to ISI. The standard formula for format complexity, P = 10log(L-1), is shown to overestimate the actual penalty for PAM-4 and PAM-8 by approximately 0.1 and 0.25 dB respectively at 1×10-3 BER. Then we extend the well-known PAM-2 ISI penalty estimation formula from the IEEE 802.3 standard 10G link modeling spreadsheet to the large BER case and generalize it for arbitrary PAM-L formats. To demonstrate and verify the BER dependence of the ISI penalty, a set of PAM-2 experiments and Monte-Carlo modeling simulations are reported. The experimental results and simulations confirm that the conventional formulas can significantly overestimate ISI penalties at relatively high BER levels. In the experiments, overestimates up to 2 dB are observed at 1×10-3 BER.

  13. Effects of Different Relative Loads on Power Performance During the Ballistic Push-up.

    Science.gov (United States)

    Wang, Ran; Hoffman, Jay R; Sadres, Eliahu; Bartolomei, Sandro; Muddle, Tyler W D; Fukuda, David H; Stout, Jeffrey R

    2017-12-01

    Wang, R, Hoffman, JR, Sadres, E, Bartolomei, S, Muddle, TWD, Fukuda, DH, and Stout, JR. Effects of different relative loads on power performance during the ballistic push-up. J Strength Cond Res 31(12): 3411-3416, 2017-The purpose of this investigation was to examine the effect of load on force and power performance during a ballistic push-up. Sixty (24.5 ± 4.3 years, 1.75 ± 0.07 m, and 80.8 ± 13.5 kg) recreationally active men who participated in this investigation completed all testing and were included in the data analysis. All participants were required to perform a 1 repetition maximum bench press, and ballistic push-ups without external load (T1), with 10% (T2) and 20% (T3) of their body mass. Ballistic push-ups during T2 and T3 were performed using a weight loaded vest. Peak and mean force, power, as well as net impulse and flight time were determined for each ballistic push-up. Peak and mean force were both significantly greater (p ballistic push-up, regardless of the participants' level of strength.

  14. Demand, Energy, and Power Factor

    Science.gov (United States)

    1994-08-01

    POWER FACTOR DEFINITION I Basically , power factor (pf) is a measure of how effectively the plant uses the electricity it purchases from the utility. It...not be made available by the plant. U 24 This video is relatively short, less than fifteen-minutes, and covers the basics on demand, block extenders... ratemaking methodology and test period as used in determining the NC-RS rates. Pending final decision by the FERC, the Federal Government would pay a rate as

  15. Performance and driveline analyses of engine capacity in range extender engine hybrid vehicle

    Science.gov (United States)

    Praptijanto, Achmad; Santoso, Widodo Budi; Nur, Arifin; Wahono, Bambang; Putrasari, Yanuandri

    2017-01-01

    In this study, range extender engine designed should be able to meet the power needs of a power generator of hybrid electrical vehicle that has a minimum of 18 kW. Using this baseline model, the following range extenders will be compared between conventional SI piston engine (Baseline, BsL), engine capacity 1998 cm3, and efficiency-oriented SI piston with engine capacity 999 cm3 and 499 cm3 with 86 mm bore and stroke square gasoline engine in the performance, emission prediction of range extender engine, standard of charge by using engine and vehicle simulation software tools. In AVL Boost simulation software, range extender engine simulated from 1000 to 6000 rpm engine loads. The highest peak engine power brake reached up to 38 kW at 4500 rpm. On the other hand the highest torque achieved in 100 Nm at 3500 rpm. After that using AVL cruise simulation software, the model of range extended electric vehicle in series configuration with main components such as internal combustion engine, generator, electric motor, battery and the arthemis model rural road cycle was used to simulate the vehicle model. The simulation results show that engine with engine capacity 999 cm3 reported the economical performances of the engine and the emission and the control of engine cycle parameters.

  16. 2D edge plasma modeling extended up to the main chamber

    Energy Technology Data Exchange (ETDEWEB)

    Dekeyser, W., E-mail: wouter.dekeyser@mech.kuleuven.be [Department of Mechanical Engineering, Katholieke Universiteit Leuven, Celestijnenlaan 300A, 3001 Leuven (Belgium); Baelmans, M. [Department of Mechanical Engineering, Katholieke Universiteit Leuven, Celestijnenlaan 300A, 3001 Leuven (Belgium); Reiter, D.; Boerner, P.; Kotov, V. [Institut fuer Plasmaphysik, Forschungszentrum Juelich GmbH, EURATOM-Association, Trilateral Euregio Cluster, D-52425 Juelich (Germany)

    2011-08-01

    Far SOL plasma flow, and hence main chamber recycling and plasma surface interaction, are today still only very poorly described by current 2D fluid edge codes, such as B2, UEDGE or EDGE2D, due to a common technical limitation. We have extended the B2 plasma fluid solver in the current ITER version of B2-EIRENE (SOLPS4.3) to allow plasma solutions to be obtained up to the 'real vessel wall', at least on the basis of ad hoc far SOL transport models. We apply here the kinetic Monte Carlo Code EIRENE on such plasma solutions to study effects of this model refinement on main chamber fluxes and sputtering, for an ITER configuration. We show that main chamber sputtering may be significantly modified both due to thermalization of CX neutrals in the far SOL and poloidally highly asymmetric plasma wall contact, as compared to hitherto applied teleportation of particle fluxes across this domain.

  17. Device for the nuclear reactor automatic start-up and power control

    International Nuclear Information System (INIS)

    Nikiforov, B.N.; Volkov, A.V.; Ogon'kov, A.I.

    1978-01-01

    A description and flowsheet of a reactor start-up and power-control automatic device containing no nonlinear elements with a relay characteristic are presented. The device consists of two independent channels for measuring the physical power and time (period) constant of the reactor. Requirements for the device are considered, based on the condition of a minimum permissible number of a servomechanism operations due to fluctuations of an input signal which appear because of the statistical nature of processes taking place in the reactor. It is noted that the threshold amplifier used in the device allows a considerable decrease of the reactor start-up time

  18. Reactor power control device in BWR power plant

    International Nuclear Information System (INIS)

    Kurosawa, Tsuneo.

    1997-01-01

    The present invention provides a device for controlling reactor power based on a start-up/shut down program in a BWR type reactor, as well as for detecting deviation, if occurs, of the power from the start-up/shut down program, to control a recycling flow rate control system or control rod drive mechanisms. Namely, a power instruction section successively executes the start-up/shut down program and controls the coolant recycling system and the control rod driving mechanisms to control the power. A current state monitoring and calculation section receives a process amount, calculates parameters showing the plant state, compares/monitors them with predetermined values, detecting the deviation, if occurs, of the plant state from the start-up/shut down program, and prevents output of a power increase control signal which leads to power increase. A forecasting and monitoring/calculation section forecasts and calculates the plant state when not yet executed steps of the start-up/shut down program are performed, stops the execution of the start-up/shut down program in the next step in a case of forecasting that the results of the calculation will deviate from the start-up/shut down program. (I.S.)

  19. TEST OF THE CATCH-UP HYPOTHESIS IN AFRICAN AGRICULTURAL GROWTH RATES

    Directory of Open Access Journals (Sweden)

    Kalu Ukpai IFEGWU

    2015-11-01

    Full Text Available The paper tested the catch-up hypothesis in agricultural growth rates of twenty-six African countries. Panel data used was drawn from the Food and Agricultural Organization Statistics (FAOSTAT of the United Nations. The Data Envelopment Analysis Method for measuring productivity was used to estimate productivity growth rates. The cross-section framework consisting of sigma-convergence and beta-convergence was employed to test the catching up process. Catching up is said to exist if the value of beta is negative and significant. Since catching up does not necessarily imply narrowing of national productivity inequalities, sigma-convergence which measures inequality, was estimated for the same variables. The results showed evidence of the catch-up process, but failed to find a narrowing of productivity inequalities among countries.

  20. Extending the Limits of Wireless Power Transfer to Miniaturized Implantable Electronic Devices

    Directory of Open Access Journals (Sweden)

    Hugo Dinis

    2017-12-01

    Full Text Available Implantable electronic devices have been evolving at an astonishing pace, due to the development of fabrication techniques and consequent miniaturization, and a higher efficiency of sensors, actuators, processors and packaging. Implantable devices, with sensing, communication, actuation, and wireless power are of high demand, as they pave the way for new applications and therapies. Long-term and reliable powering of such devices has been a challenge since they were first introduced. This paper presents a review of representative state of the art implantable electronic devices, with wireless power capabilities, ranging from inductive coupling to ultrasounds. The different power transmission mechanisms are compared, to show that, without new methodologies, the power that can be safely transmitted to an implant is reaching its limit. Consequently, a new approach, capable of multiplying the available power inside a brain phantom for the same specific absorption rate (SAR value, is proposed. In this paper, a setup was implemented to quadruple the power available in the implant, without breaking the SAR limits. A brain phantom was used for concept verification, with both simulation and measurement data.

  1. Extending solid state laser performance

    Science.gov (United States)

    Miesak, Ed

    2017-02-01

    Coherent Diode-Pumped Solid-State Orlando (CDO), formerly known as Lee Laser, headquartered in Orlando Florida produces CW and pulsed solid state lasers. Primary wavelengths include 1064 nm, 532 nm, and 355 nm. Other wavelengths produced include 1320 nm, 15xx nm, and 16xx nm. Pulse widths are in the range of singles to hundreds of nanoseconds. Average powers are in the range of a few watts to 1000 watts. Pulse repetition rates are typically in the range of 100 Hz to 100 KHz. Laser performance parameters are often modified according to customer requests. Laser parameters that can be adjusted include average power, pulse repetition rate, pulse length, beam quality, and wavelength. Laser parameters are typically cross-coupled such that adjusting one may change some or all of the others. Customers often request one or more parameters be changed without changing any of the remaining parameters. CDO has learned how to accomplish this successfully with rapid turn-around times and minimal cost impact. The experience gained by accommodating customer requests has produced a textbook of cause and effect combinations of laser components to accomplish almost any parameter change request. Understanding the relationships between component combinations provides valuable insight into lasing effects allowing designers to extend laser performance beyond what is currently available. This has led to several break through products, i.e. >150W average power 355 nm, >60W average power 6 ps 1064 nm, pulse lengths longer than 400 ns at 532 nm with average power >100W, >400W 532 nm with pulse lengths in the 100 ns range.

  2. Extended Thermodynamics for Dense Gases up to Whatever Order and with Only Some Symmetries

    Directory of Open Access Journals (Sweden)

    Maria Cristina Carrisi

    2015-10-01

    Full Text Available Extended Thermodynamics of dense gases is characterized by two hierarchies of field equations, which allow one to overcome some restrictions on the generality of the previous models. This idea has been introduced by Arima, Taniguchi, Ruggeri and Sugiyama. In the case of a 14-moment model, they have found the closure of the balance equations up to second order with respect to equilibrium. Here, the closure is obtained up to whatever order and imposing only the necessary symmetry conditions. It comes out that the first non-symmetric parts of the higher order fluxes appear only at third order with respect to equilibrium, even if Arima, Taniguchi, Ruggeri and Sugiyama found a non-symmetric part proportional to an arbitrary constant also at first order with respect to equilibrium. Consequently, this constant must be zero, as Arima, Taniguchi, Ruggeri and Sugiyama assumed in the applications and on an intuitive ground.

  3. An extended NSGA-III for solution multi-objective hydro-thermal-wind scheduling considering wind power cost

    International Nuclear Information System (INIS)

    Yuan, Xiaohui; Tian, Hao; Yuan, Yanbin; Huang, Yuehua; Ikram, Rana M.

    2015-01-01

    Highlights: • Multi-objective hydro-thermal-wind scheduling model (MO-HTWS) is establish. • The extra cost in MO-HTWS problem caused by wind uncertainty is considered. • An extended NSGA-III is proposed to solve MO-HTWS problem. • Constraint handling strategies are presented to modify infeasible solutions. • The feasibility and effectiveness of the proposed method is verified by example. - Abstract: Due to the characteristics of clean and renewable, wind power is significant to economic and environmental operation of electric power system so that it attracts more and more attention from researchers. This paper integrates wind power with hydrothermal scheduling to establish multi-objective economic emission hydro-thermal-wind scheduling problem (MO-HTWS) model with considering wind uncertain cost. To solve MO-HTWS problem with various complicated constraints, this paper extends NSGA-III by introducing the dominance relationship criterion based on constraint violation to select new generation. Moreover, the constraint handling strategy which repairs the infeasible solutions by modifying the decision variables in feasible zone according to the violation amount is proposed. Finally, a daily scheduling example of hydro-thermal-wind system is used to test the ability of NSGA-III for solving MO-HTWS problem. It is concluded from the superior quality and good distribution of the Pareto optimal solutions that, NSGA-III can offer an efficient alternative for optimizing MO-HTWS problem

  4. The impact of hybrid energy storage on power quality, when high power pulsed DC loads are operated on a microgrid testbed

    Science.gov (United States)

    Kelley, Jay Paul

    As the Navy's demands for high power transient loads evolves, so too does the need for alternative energy sources to back-up the more traditional power generation. Such applications in need of support include electrical grid backup and directed energy weapon systems such as electromagnetic launchers, laser systems, and high power microwave generators, among others. Among the alternative generation sources receiving considerable attention are energy storage devices such as rechargeable electrochemical batteries and capacitors. In such applications as those mentioned above, these energy storage devices offer the ability to serve a dual role as both a power source to the various loads as well high power loads themselves to the continual generation when the high power transient loads are in periods of downtime. With the recent developments in electrochemical energy storage, lithium-ion batteries (LIBs) seem like the obvious choice, but previous research has shown that the elevated rates of charging can be detrimental to both the cycle life and the operational life span of the device. In order to preserve the batteries, their charge rate must be limited. One proposed method to accomplish the dual role task mentioned above, while preserving the life of the batteries, is by combining high energy density LIBs with high power density electric double layer capacitors (EDLCs) or lithium-ion capacitors (LICs) using controllable power electronics to adjust the flow of power to and from each device. Such a configuration is typically referred to as hybrid energy storage module (HESM). While shipboard generators start up, the combined high energy density and high power density of the HESM provides the capability to source critical loads for an extended period of time at the high rates they demand. Once the generator is operationally efficient, the HESM can act as a high energy reservoir to harvest the energy from the generator while the loads are in short periods of inactivity

  5. Increasing power generation for scaling up single-chamber air cathode microbial fuel cells

    KAUST Repository

    Cheng, Shaoan; Logan, Bruce E.

    2011-01-01

    Scaling up microbial fuel cells (MFCs) requires a better understanding the importance of the different factors such as electrode surface area and reactor geometry relative to solution conditions such as conductivity and substrate concentration. It is shown here that the substrate concentration has significant effect on anode but not cathode performance, while the solution conductivity has a significant effect on the cathode but not the anode. The cathode surface area is always important for increasing power. Doubling the cathode size can increase power by 62% with domestic wastewater, but doubling the anode size increases power by 12%. Volumetric power density was shown to be a linear function of cathode specific surface area (ratio of cathode surface area to reactor volume), but the impact of cathode size on power generation depended on the substrate strength (COD) and conductivity. These results demonstrate the cathode specific surface area is the most critical factor for scaling-up MFCs to obtain high power densities. © 2010 Elsevier Ltd.

  6. Increasing power generation for scaling up single-chamber air cathode microbial fuel cells

    KAUST Repository

    Cheng, Shaoan

    2011-03-01

    Scaling up microbial fuel cells (MFCs) requires a better understanding the importance of the different factors such as electrode surface area and reactor geometry relative to solution conditions such as conductivity and substrate concentration. It is shown here that the substrate concentration has significant effect on anode but not cathode performance, while the solution conductivity has a significant effect on the cathode but not the anode. The cathode surface area is always important for increasing power. Doubling the cathode size can increase power by 62% with domestic wastewater, but doubling the anode size increases power by 12%. Volumetric power density was shown to be a linear function of cathode specific surface area (ratio of cathode surface area to reactor volume), but the impact of cathode size on power generation depended on the substrate strength (COD) and conductivity. These results demonstrate the cathode specific surface area is the most critical factor for scaling-up MFCs to obtain high power densities. © 2010 Elsevier Ltd.

  7. Shortening start-up and an extension of the power unit load range

    Directory of Open Access Journals (Sweden)

    Taler Jan

    2017-01-01

    Full Text Available A power plant with additional water pressure tanks was proposed. The maximum rise in the block electric power resulting from the shut-off of low-pressure regenerative heaters was determined. At that time, the boiler is fed with hot water from water pressure tanks acting as heat accumulators. Accumulation of hot water in water tanks is also proposed in the periods of the power unit small load. In order to lower the plant electric power in the off-peak night hours, water heated to the nominal temperature in low-pressure regenerative heaters is directed from the feed water tank to pressure tanks. The water accumulated during the night is used to feed the boiler during the period of peak demand for electricity. Pressure accumulators are proposed to be used for the rapid start-up of the boiler from a cold state. The evaporator of the boiler is filled at the beginning of start-up with hot water from the accumulators. Drops in the power block electric power were determined for different capacities of the tanks and periods when they are charged. The tanks may also be used to ensure a sudden increase in the electric power of the unit that is operating in the automatic system of frequency and power control (in Polish: ARCM.

  8. 78 FR 62616 - Integrated System Power Rates

    Science.gov (United States)

    2013-10-22

    .... James K. McDonald, Vice President for Corporate Operations/Chief Operating Office, Southwestern Power...) 595-6690, jim.mcdonald@swpa.gov . SUPPLEMENTARY INFORMATION: Rate Order No. SWPA-66, which has been... final approval by the Federal Energy Regulatory Commission. Available: In the marketing area of...

  9. 75 FR 1363 - Integrated System Power Rates

    Science.gov (United States)

    2010-01-11

    ... increased. Those customers taking transformation service will be affected by an increase in that rate... Regulation Purchased. With factors defined as follows: RPA = The Customer's specific monthly dollar amount of... formulas provided in Customers' contracts indicate an overrun on Hydro Peaking Power, and investigation...

  10. Proposal for implementation of alternative source term in the nuclear power plant of Laguna Verde

    International Nuclear Information System (INIS)

    Bazan L, A.; Lopez L, M.; Vargas A, A.; Cardenas J, J. B.

    2009-10-01

    In 2010 the nuclear power plant of Laguna Verde will implement the extended power upbeat in both units of the plant. Agree with methodology of NEDC-33004P-A, (constant pressure power up rate), and the source term of core, for accidents evaluations, were increased in proportion to the ratio of power level. This means that for the case of a design basis accident of loss of coolant an increase of power of 15% originated an increase of 15% in dose to main control room. Using the method of NEDC-33004P-A to extended power upbeat conditions was determined that the dose value to main control room is very near to regulatory limit established by SRP 6.4. By the above and in order to recover the margin, the nuclear power plant of Laguna Verde will calculate an alternative source term following the criteria established in RG 1.183 (alternative radiological source term for evaluating DBA at nuclear power reactor). This approach also have a more realistic dose value using the criterion of 10-CFR-50.67, in addition is predicted to get the benefit of additional operational flexibilities. This paper present the proposal of implementing the alternative source term in Laguna Verde. (Author)

  11. Heat rate curve approximation for power plants without data measuring devices

    Energy Technology Data Exchange (ETDEWEB)

    Poullikkas, Andreas [Electricity Authority of Cyprus, P.O. Box 24506, 1399 Nicosia (CY

    2012-07-01

    In this work, a numerical method, based on the one-dimensional finite difference technique, is proposed for the approximation of the heat rate curve, which can be applied for power plants in which no data acquisition is available. Unlike other methods in which three or more data points are required for the approximation of the heat rate curve, the proposed method can be applied when the heat rate curve data is available only at the maximum and minimum operating capacities of the power plant. The method is applied on a given power system, in which we calculate the electricity cost using the CAPSE (computer aided power economics) algorithm. Comparisons are made when the least squares method is used. The results indicate that the proposed method give accurate results.

  12. Method of starting up PWR type reactor

    International Nuclear Information System (INIS)

    Kadokami, Akira; Ueno, Ryuji; Tsuge, Ayao; Onimura, Kichiro; Ochi, Tatsuya.

    1988-01-01

    Purpose: To start-up a PWR type reactor so as to effectively impregnate and concentrate corrosion inhibitors in intergranular corrosive faces. Method: Upon reactor start-up, after transferring from the warm zero output state to thermal power loaded state and injecting corrosion inhibitors, thermal power is returned to zero and, subsequently, increased up to a rated power. By selecting the thermal power upon injecting the corrosion inhibitors to a steam generator body, that is, by selecting a thermal power load that starts to boil in heat conduction tubes, feedwater in the clavis portion can be formed into an appropriate boiling convection and, accordingly, the corrosion inhibitors can be penetrated to the clevis portion at a higher rate and in a greater amount as compared with those under zero power condition. Subsequently, when the thermal power is reduced, a sub-cooled state is attained in the clevis portion, in which steams present in the intergranular corrosion faces in the heat conduction tubes are condensated. As a result, the corrosion inhibitors at high concentration are impregnated into the intergranular corrosive faces to provide excellent effects. (Kamimura, M.)

  13. Improved detection rate of structural abnormalities in the first trimester using an extended examination protocol.

    Science.gov (United States)

    Iliescu, D; Tudorache, S; Comanescu, A; Antsaklis, P; Cotarcea, S; Novac, L; Cernea, N; Antsaklis, A

    2013-09-01

    To assess the potential of first-trimester sonography in the detection of fetal abnormalities using an extended protocol that is achievable with reasonable resources of time, personnel and ultrasound equipment. This was a prospective two-center 2-year study of 5472 consecutive unselected pregnant women examined at 12 to 13 + 6 gestational weeks. Women were examined using an extended morphogenetic ultrasound protocol that, in addition to the basic evaluation, involved a color Doppler cardiac sweep and identification of early contingent markers for major abnormalities. The prevalence of lethal and severe malformations was 1.39%. The first-trimester scan identified 40.6% of the cases detected overall and 76.3% of major structural defects. The first-trimester detection rate (DR) for major congenital heart disease (either isolated or associated with extracardiac abnormalities) was 90% and that for major central nervous system anomalies was 69.5%. In fetuses with increased nuchal translucency (NT), the first-trimester DR for major anomalies was 96%, and in fetuses with normal NT it was 66.7%. Most (67.1%) cases with major abnormalities presented with normal NT. A detailed first-trimester anomaly scan using an extended protocol is an efficient screening method to detect major fetal structural abnormalities in low-risk pregnancies. It is feasible at 12 to 13 + 6 weeks with ultrasound equipment and personnel already used for routine first-trimester screening. Rate of detection of severe malformations is greater in early- than in mid-pregnancy and on postnatal evaluation. Early heart investigation could be improved by an extended protocol involving use of color Doppler. Copyright © 2013 ISUOG. Published by John Wiley & Sons Ltd.

  14. High-dose Extended-Field Irradiation and High-Dose-Rate Brachytherapy With Concurrent Chemotherapy for Cervical Cancer With Positive Para-Aortic Lymph Nodes

    International Nuclear Information System (INIS)

    Kim, Young Seok; Kim, Jong Hoon; Ahn, Seung Do; Lee, Sang-wook; Shin, Seong Soo; Nam, Joo-Hyun; Kim, Young-Tak; Kim, Yong-Man; Kim, Jong-Hyeok; Choi, Eun Kyung

    2009-01-01

    Purpose: To determine the efficacy and toxicity of extended-field radiotherapy (RT) with concurrent platinum-based chemotherapy in patients with uterine cervical carcinoma and positive para-aortic nodes. Methods and Materials: We retrospectively reviewed the results for 33 women with Stage IB-IVB cervical cancer. Each patient had received 59.4 Gy, including a three-dimensional conformal boost to the para-aortic lymph nodes and 41.4-50.4 Gy of external beam radiotherapy to the pelvis. Each patient also underwent six or seven applications of high-dose-rate brachytherapy (median, 5 Gy to point A at each session). Results: The median follow-up period of surviving patients was 39 months. The most common acute toxicity was hematologic, observed in 23 women. Severe acute and late gastrointestinal toxicity was observed in 3 and 4 patients, respectively. More than three-quarters of patients showed a complete response, encompassing the primary mass, metastatic pelvic, and para-aortic lymph nodes. Of the 33 women, 15 had no evidence of disease, 6 had persistent disease, 4 developed in-field failures, and 6 developed distant failures. The 5-year overall and disease-free survival rate was 47% and 42%, respectively. Conclusion: Concurrent chemoradiotherapy with extended-field radiotherapy is feasible in women with uterine cervical carcinoma and positive para-aortic lymph nodes, with acceptable late morbidity and a high survival rate, although it was accompanied by substantial acute toxicity.

  15. Extending producer responsibility up and down the supply chain, challenges and limitation.

    Science.gov (United States)

    Scheijgrond, Jan-Willem

    2011-09-01

    Producers are given increasing responsibility by governmental organizations to address environmental and human rights issues along the supply chain. While producers indeed have a responsibility to address these issues, governments' expectations of producers are often too high and in some cases unrealistic. Ruggie's framework to protect, respect and remedy provides a useful tool to determine the responsibilities of government and business in relation to human rights. If it is applied to product-related environmental aspects, which affect human rights, it offers a good tool to evaluate whether producer responsibility has been implemented in a way to institutionally align business and governments. An analysis of extended producer responsibility up and down the supply chain on the basis of waste electrical and electronic equipment (WEEE) legislation, REACH legislation and conflict minerals shows that such alignment has not been achieved.

  16. Solid state pump lasers with high power and high repetition rate

    International Nuclear Information System (INIS)

    Oba, Masaki; Kato, Masaaki; Arisawa, Takashi

    1995-01-01

    We built a laser diode pumped solid state green laser (LDPSSGL) rated at high repetition rate. Two laser heads are placed in one cavity with a rotator in between to design to avoid thermal lensing and thermal birefringence effect. Although average green laser power higher than 10 W was obtained at 1 kHz repetition rate with pulse width of 20-30 nsec, the beam quality was so much deteriorated that energy efficiency was as low as 2 %. Learning from this experience that high power oscillator causes a lot of thermal distortion not only in the laser rod but also in the Q-switch device, we proceeded to built a oscillator/amplifier system. A low power oscillator has a slab type crystal in the cavity. As a result spatial distribution of laser power was extremely improved. As we expect that the high repetition rate solid state laser should be CW operated Q-switch type laser from the view point of lifetime of diode lasers, a conventional arc lamp pumped CW Q-switch green YAG laser of which the repetition rate is changeable from 1 kHz to 5 kHz and the pulse width is 250-570 nsec was also tested to obtain pumping characteristics of a dye laser as a function of power, pulse width etc., and dye laser pulse width of 100-130 nsec were obtained. (author)

  17. Experience in start-up of the South-Ukrainian-2 power unit with the WWER-1000 reactor

    International Nuclear Information System (INIS)

    Belov, Yu.V.; Kazakov, V.A.; Kirilov, V.V.; Kryakvin, L.V.

    1987-01-01

    The volume, sequence and dates of works fulfilled during hot testing, physical and power start-ups and while bringing output of the South-Ukranian-2 power unit with the WWER-1000 reactor to the design figure are described. The works were fulfilled according to the standard schedules from October in 1984 till April in 1985. Combination of the stages and intensification of works before the physical start-up have allowed to shorten the dates by 90 days as compared to the schedule. The physical and power start-ups, including bringing reactor output to the design figure, were performed during 140 days, that permits to shorten the dates by 20 days more. The results of physical experiments carried out at the South-Ukranian-2 power unit, are in good agreement with the data obtained at the first power units of the given and Kalinin NPPs. Besides, during physical and power start-ups additional measures ensuring nuclear safety are developed

  18. Documentation for WIMSD-formatted libraries based on ENDF/B-VII.1 evaluated nuclear data files with extended actinide burn-up chains and cross section data up to 2000 K for fuel materials

    International Nuclear Information System (INIS)

    López Aldama, Daniel

    2014-11-01

    In the frame of WIMS Library Update Project the WIMSD-IAEA-69 and WIMSD-IAEA-172 libraries were prepared and made available at the Nuclear Data Section (NDS) of the International Atomic Energy Agency (IAEA). The main libraries were prepared from different sources of evaluated nuclear data that were available before December 2003. Also others WIMSD libraries were prepared from the major evaluated nuclear data libraries and made available at http://www-nds.iaea.org/wimsd. During the last ten years new libraries have been prepared every time that a major version of an evaluated nuclear data library has been released, namely JEFF-3.1 and ENDF/B-VII.0. Recently, end-users have requested to extend the temperature ranges of fuel materials included in the libraries and also to extend the burn-up chains to higher actinides up to Cf-254. The inclusion of new structural materials, like bismuth, has been also considered. Therefore, new WIMSD-formatted libraries in the 69- and 172-energy structure have been prepared with more materials, extended actinides burn-up chains and higher temperatures in thermal and resonance range

  19. Low cost power lead extended pre-compliance conducted EMI measurement setup and diagnostics with compact LISN

    CSIR Research Space (South Africa)

    Grobler, Inus

    2013-06-01

    Full Text Available An extended pre-compliance measurement setup has been created in the development laboratory to measure and diagnose conducted EMI up to tOO MHz without the use of a spectrum analyser. A dual compact Line Impedance Stabilisation Network (LISN) had...

  20. Demonstration of Multi-Gbps Data Rates at Ka-Band Using Software-Defined Modem and Broadband High Power Amplifier for Space Communications

    Science.gov (United States)

    Simons, Rainee N.; Wintucky, Edwin G.; Landon, David G.; Sun, Jun Y.; Winn, James S.; Laraway, Stephen; McIntire, William K.; Metz, John L.; Smith, Francis J.

    2011-01-01

    The paper presents the first ever research and experimental results regarding the combination of a software-defined multi-Gbps modem and a broadband high power space amplifier when tested with an extended form of the industry standard DVB-S2 and LDPC rate 9/10 FEC codec. The modem supports waveforms including QPSK, 8-PSK, 16-APSK, 32-APSK, 64-APSK, and 128-QAM. The broadband high power amplifier is a space qualified traveling-wave tube (TWT), which has a passband greater than 3 GHz at 33 GHz, output power of 200 W and efficiency greater than 60 percent. The modem and the TWTA together enabled an unprecedented data rate at 20 Gbps with low BER of 10(exp -9). The presented results include a plot of the received waveform constellation, BER vs. E(sub b)/N(sub 0) and implementation loss for each of the modulation types tested. The above results when included in an RF link budget analysis show that NASA s payload data rate can be increased by at least an order of magnitude (greater than 10X) over current state-of-practice, limited only by the spacecraft EIRP, ground receiver G/T, range, and available spectrum or bandwidth.

  1. Achievable data rate in spectrum-sharing channels with variable-rate variable-power primary users

    KAUST Repository

    Yang, Yuli

    2012-08-01

    In this work, we propose a transmission strategy for secondary users (SUs) within a cognitive radio network where primary users (PUs) exploit variable-rate variable-power modulation. By monitoring the PU\\'s transmissions, the SU adjusts its transmit power based on the gap between the PU\\'s received effective signal-to-noise power ratio (SNR) and the lower SNR boundary for the modulation mode that is being used in the primary link. Thus, at the SU\\'s presence, the PU\\'s quality of service (QoS) is guaranteed without increasing its processing complexity thanks to no interference cancellation required in the PU\\'s operation. To demonstrate the advantage of our proposed transmission strategy, we analyze the secondary user\\'s achievable data rate by taking into account different transmission capabilities for the secondary transmitter. The corresponding numerical results not only prove the validity of our derivations but also provide a convenient tool for the network design with the proposed transmission strategy. © 2012 IEEE.

  2. Triboelectric Nanogenerator Enabled Body Sensor Network for Self-Powered Human Heart-Rate Monitoring.

    Science.gov (United States)

    Lin, Zhiming; Chen, Jun; Li, Xiaoshi; Zhou, Zhihao; Meng, Keyu; Wei, Wei; Yang, Jin; Wang, Zhong Lin

    2017-09-26

    Heart-rate monitoring plays a critical role in personal healthcare management. A low-cost, noninvasive, and user-friendly heart-rate monitoring system is highly desirable. Here, a self-powered wireless body sensor network (BSN) system is developed for heart-rate monitoring via integration of a downy-structure-based triboelectric nanogenerator (D-TENG), a power management circuit, a heart-rate sensor, a signal processing unit, and Bluetooth module for wireless data transmission. By converting the inertia energy of human walking into electric power, a maximum power of 2.28 mW with total conversion efficiency of 57.9% was delivered at low operation frequency, which is capable of immediately and sustainably driving the highly integrated BSN system. The acquired heart-rate signal by the sensor would be processed in the signal process circuit, sent to an external device via the Bluetooth module, and displayed on a personal cell phone in a real-time manner. Moreover, by combining a TENG-based generator and a TENG-based sensor, an all-TENG-based wireless BSN system was developed, realizing continuous and self-powered heart-rate monitoring. This work presents a potential method for personal heart-rate monitoring, featured as being self-powered, cost-effective, noninvasive, and user-friendly.

  3. Power ramping/cycling experience and operational recommendations in KWU power plants

    International Nuclear Information System (INIS)

    Jan, R. von; Wunderlich, F.; Holzer, R.

    1980-01-01

    The power cycling and ramping experience of KWU is based on experiments in test and commercial reactors, and on evaluation of plant operation (PHWR, PWR and BWR). Power cycling of fuel rods have never lead to PCI failures. In ramping experiments, for fast ramps PCI failure thresholds of 480/420 W/cm are obtained at 12/23 GWd/t(U) burn-up for pressurized PWR fuel. No failures occurred during limited exceedance of the threshold with reduced ramp rate. Operational recommendations used by KWU are derived from experiments and plant experience. The effects of ramping considerations on plant operation is discussed. No rate restrictions are required for start-ups during an operating cycle or load follow operation within set limits for the distortion of the local power distribution. In a few situations, e.g. start-up after refueling, ramp rates of 1 to 5 %/h are recommended depending on plant and fuel design

  4. International symposium on storage of spent fuel from power reactors. Book of extended synopses

    International Nuclear Information System (INIS)

    1998-11-01

    This book of extended synopses includes papers presented at the International Symposium on Storage of Spent Fuel from Power Reactors organized by IAEA and held in Vienna from 9 to 13 November 1998. It deals with the problems of spent fuel management being an outstanding stage in the nuclear fuel cycle, strategy of interim spent fuel storage, transportation and encapsulation of spent fuel elements from power reactors. Spent fuel storage facilities at reactor sites are always wet while spent fuel storage facilities away from reactor are either wet or dry including casks and vaults. Different design solutions and constructions of storage or transportation casks as well as storing facilities are presented, as well as status of spent fuel storage together with experiences achieved in a number of member states, in the frame of safety, licensing and regulating procedures

  5. International symposium on storage of spent fuel from power reactors. Book of extended synopses

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-11-01

    This book of extended synopses includes papers presented at the International Symposium on Storage of Spent Fuel from Power Reactors organized by IAEA and held in Vienna from 9 to 13 November 1998. It deals with the problems of spent fuel management being an outstanding stage in the nuclear fuel cycle, strategy of interim spent fuel storage, transportation and encapsulation of spent fuel elements from power reactors. Spent fuel storage facilities at reactor sites are always wet while spent fuel storage facilities away from reactor are either wet or dry including casks and vaults. Different design solutions and constructions of storage or transportation casks as well as storing facilities are presented, as well as status of spent fuel storage together with experiences achieved in a number of member states, in the frame of safety, licensing and regulating procedures Refs, figs, tabs

  6. Rated power factor and excitation system of large turbine generator

    International Nuclear Information System (INIS)

    Tokumitsu, Iwao; Watanabe, Takashi; Banjou, Minoru.

    1979-01-01

    As for the rated power factor of turbine generators for thermal power stations, 90% has been adopted since around 1960. On the other hand, power transmission system has entered 500 kV age, and 1,000 kV transmission is expected in the near future. As for the supply of reactive power from thermal and nuclear turbine generators, the necessity of supplying leading reactive power has rather increased. Now, the operating power factor of thermal and nuclear generators becomes 96 to 100% actually. As for the excess stability of turbine generators owing to the strengthening of transmission system and the adoption of super-high voltage, the demand of strict conditions can be dealt with by the adoption of super-fast response excitation system of thyristor shunt winding self exciting type. The adoption of the turbine generators with 90 to 95% power factor and the adoption of the thyristor shunt winding self exciting system were examined and evaluated. The rated power factor of generators, excitation system and economy of adopting these systems are explained. When the power factor of generators is increased from 0.9 to 0.95, about 6% of saving can be obtained in the installation cost. When the thyristor shunt winding self excitation is adopted, it is about 10% more economical than AC excitation. (Kako, I.)

  7. Start-up performance of parabolic trough concentrating solar power plants

    DEFF Research Database (Denmark)

    Ferruzza, Davide; Topel, Monika; Basaran, Ibrahim

    2017-01-01

    Concentrating solar power plants, even though they can be integrated with thermal energy storage, are still subjected to cyclic start-up and shut-downs. As a consequence, in order to maximize their profitability and performance, the flexibility with respect to transient operations is essential...

  8. Multichannel low power time-to-digital converter card with 21 ps precision and full scale range up to 10 μs

    International Nuclear Information System (INIS)

    Tamborini, D.; Portaluppi, D.; Villa, F.; Tosi, A.; Tisa, S.

    2014-01-01

    We present a Time-to-Digital Converter (TDC) card with a compact form factor, suitable for multichannel timing instruments or for integration into more complex systems. The TDC Card provides 10 ps timing resolution over the whole measurement range, which is selectable from 160 ns up to 10 μs, reaching 21 ps rms precision, 1.25% LSB rms differential nonlinearity, up to 3 Mconversion/s with 400 mW power consumption. The I/O edge card connector provides timing data readout through either a parallel bus or a 100 MHz serial interface and further measurement information like input signal rate and valid conversion rate (typically useful for time-correlated single-photon counting application) through an independent serial link

  9. Multichannel low power time-to-digital converter card with 21 ps precision and full scale range up to 10 μs

    Energy Technology Data Exchange (ETDEWEB)

    Tamborini, D., E-mail: davide.tamborini@polimi.it; Portaluppi, D.; Villa, F.; Tosi, A. [Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, Piazza Leonardo Da Vinci 32, 20133 Milano (Italy); Tisa, S. [Micro Photon Devices, via Stradivari 4, 39100 Bolzano (Italy)

    2014-11-15

    We present a Time-to-Digital Converter (TDC) card with a compact form factor, suitable for multichannel timing instruments or for integration into more complex systems. The TDC Card provides 10 ps timing resolution over the whole measurement range, which is selectable from 160 ns up to 10 μs, reaching 21 ps rms precision, 1.25% LSB rms differential nonlinearity, up to 3 Mconversion/s with 400 mW power consumption. The I/O edge card connector provides timing data readout through either a parallel bus or a 100 MHz serial interface and further measurement information like input signal rate and valid conversion rate (typically useful for time-correlated single-photon counting application) through an independent serial link.

  10. Multichannel low power time-to-digital converter card with 21 ps precision and full scale range up to 10 μs.

    Science.gov (United States)

    Tamborini, D; Portaluppi, D; Villa, F; Tisa, S; Tosi, A

    2014-11-01

    We present a Time-to-Digital Converter (TDC) card with a compact form factor, suitable for multichannel timing instruments or for integration into more complex systems. The TDC Card provides 10 ps timing resolution over the whole measurement range, which is selectable from 160 ns up to 10 μs, reaching 21 ps rms precision, 1.25% LSB rms differential nonlinearity, up to 3 Mconversion/s with 400 mW power consumption. The I/O edge card connector provides timing data readout through either a parallel bus or a 100 MHz serial interface and further measurement information like input signal rate and valid conversion rate (typically useful for time-correlated single-photon counting application) through an independent serial link.

  11. Extended Gersgorin Theorem-Based Parameter Feasible Domain to Prevent Harmonic Resonance in Power Grid

    Directory of Open Access Journals (Sweden)

    Tao Lin

    2017-10-01

    Full Text Available Harmonic resonance may cause abnormal operation and even damage of power facilities, further threatening normal and safe operation of power systems. For renewable energy generations, controlled loads and parallel reactive power compensating equipment, their operating statuses can vary frequently. Therefore, the parameters of equivalent fundamental and harmonic admittance/impedance of these components exist in uncertainty, which will change the elements and eigenvalues of harmonic network admittance matrix. Consequently, harmonic resonance in power grid is becoming increasingly more complex. Hence, intense research about prevention and suppression of harmonic resonance, particularly the parameter feasible domain (PFD which can keep away from harmonic resonance, are needed. For rapid online evaluation of PFD, a novel method without time-consuming pointwise precise eigenvalue computations is proposed. By analyzing the singularity of harmonic network admittance matrix, the explicit sufficient condition that the matrix elements should meet to prevent harmonic resonance is derived by the extended Gersgorin theorem. Further, via the non-uniqueness of similar transformation matrix (STM, a strategy to determine the appropriate STM is proposed to minimize the conservation of the obtained PFD. Eventually, the availability and advantages in computation efficiency and conservation of the method, are demonstrated through four different scale benchmarks.

  12. Phenomenological scattering-rate model for the simulation of the current density and emission power in mid-infrared quantum cascade lasers

    Energy Technology Data Exchange (ETDEWEB)

    Kurlov, S. S. [Department of Physics, Humboldt-Universität zu Berlin, Newtonstraße 15, 12489 Berlin (Germany); Institute of Semiconductor Physics, National Academy of Sciences, pr. Nauki 45, Kiev-03028 (Ukraine); Flores, Y. V.; Elagin, M.; Semtsiv, M. P.; Masselink, W. T. [Department of Physics, Humboldt-Universität zu Berlin, Newtonstraße 15, 12489 Berlin (Germany); Schrottke, L.; Grahn, H. T. [Paul-Drude-Institut für Festkörperelektronik, Hausvogteiplatz 5–7, 10117 Berlin (Germany); Tarasov, G. G. [Institute of Semiconductor Physics, National Academy of Sciences, pr. Nauki 45, Kiev-03028 (Ukraine)

    2016-04-07

    A phenomenological scattering-rate model introduced for terahertz quantum cascade lasers (QCLs) [Schrottke et al., Semicond. Sci. Technol. 25, 045025 (2010)] is extended to mid-infrared (MIR) QCLs by including the energy dependence of the intersubband scattering rates for energies higher than the longitudinal optical phonon energy. This energy dependence is obtained from a phenomenological fit of the intersubband scattering rates based on published lifetimes of a number of MIR QCLs. In our approach, the total intersubband scattering rate is written as the product of the exchange integral for the squared moduli of the envelope functions and a phenomenological factor that depends only on the transition energy. Using the model to calculate scattering rates and imposing periodical boundary conditions on the current density, we find a good agreement with low-temperature data for current-voltage, power-current, and energy-photon flux characteristics for a QCL emitting at 5.2 μm.

  13. An extended diffusive model for calculating thermal diffusivity from single monopole tokamak heat pulse propagation

    International Nuclear Information System (INIS)

    Marinak, M.

    1990-02-01

    The problem of deducing χ e from measurements of the propagation of a monopole heatpulse is considered. An extended diffusive model, which takes into account perturbed sources and sinks is extended to the case of a monopole heat input. χ e is expressed as a function of two observables, the heat pulse velocity and the radial damping rate. Two simple expressions valid for two different ranges of the radius of the poloidal waist of the beam power profile are given. The expressions are valid in the heat pulse measurement region, extending radially 0.05a beyond the beam power waist to near 0.6a. The inferred χ e is a local value, not an average value of the radial χ e profile. 7 refs., 6 figs., 1 tab

  14. Program of RA reactor start-up to nominal power

    International Nuclear Information System (INIS)

    1959-01-01

    The zero start-up program is followed by the program of RA reactor start-up to nominal power. This program is described in detail and includes the following measurements: radiation characteristics at the exit of the channels; gamma and fast neutron dose distribution in the reactor; influence of absorbers on the reactivity; temperature effect; absolute flux and calibration of ionization chambers; xenon effect; thermal and hydraulics; dosimetry around the reactor; neutron flux in the reactor core and in the reactor hall; heavy water level; thermal characteristics after shutdown. A list of measuring devices and instrumentation is included with the detailed action plan and list of responsible staff members

  15. Asymmetric power device rating selection for even temperature distribution in NPC inverter

    DEFF Research Database (Denmark)

    Choi, Uimin; Blaabjerg, Frede

    2017-01-01

    the power rating and lifetime of the NPC inverter are limited by the most stressed devices. In this paper, an asymmetric power device rating selection method for the NPC inverter is proposed in order to balance the lifetimes of the power devices. The thermal distribution of the power devices is analyzed......A major drawback of the NPC inverter is an unequal power loss distribution among the power devices which leads to unequal temperature stress among them. Therefore, certain power devices experience higher temperature stress, which is the main cause of power device module failure and thus both...... based on 30 kW NPC inverter as a case study. Analytical power loss and thermal impedance models depending on the chip size are derived. Finally, using these models, the junction temperatures of the power devices depending on the chip size is discussed and a proper chip size for an even temperature...

  16. Minimization of the external heating power by long fusion power rise-up time for self-ignition access in the helical reactor FFHR2m

    International Nuclear Information System (INIS)

    Mitarai, O.; Sagara, A.; Chikaraishi, H.; Imagawa, S.; Shishkin, A.A.; Motojima, O.

    2006-10-01

    Minimization of the external heating power to access self-ignition is advantageous to increase the reactor design flexibility and to reduce the capital and operating costs of the plasma heating device in a helical reactor. In this work we have discovered that a larger density limit leads to a smaller value of the required confinement enhancement factor, lower density limit margin reduces the external heating power, and over 300 s of the fusion power rise-up time makes it possible to reach a minimized heating power. While the fusion power rise-up time in a tokamak is limited by the OH transformer flux or the current drive capability, any fusion power rise-up time can be employed in a helical reactor for reducing the thermal stresses of the blanket and shields, because the confinement field is generated by the external helical coils. (author)

  17. Design and optimization of G-band extended interaction klystron with high output power

    Science.gov (United States)

    Li, Renjie; Ruan, Cunjun; Zhang, Huafeng

    2018-03-01

    A ladder-type Extended Interaction Klystron (EIK) with unequal-length slots in the G-band is proposed and designed. The key parameters of resonance cavities working in the π mode are obtained based on the theoretical analysis and 3D simulation. The influence of the device fabrication tolerance on the high-frequency performance is analyzed in detail, and it is found that at least 5 μm of machining precision is required. Thus, the dynamic tuning is required to compensate for the frequency shift and increase the bandwidth. The input and output coupling hole dimensions are carefully designed to achieve high output power along with a broad bandwidth. The effect of surface roughness of the metallic material on the output power has been investigated, and it is proposed that lower surface roughness leads to higher output power. The focusing magnetic field is also optimized to 0.75 T in order to maintain the beam transportation and achieve high output power. With 16.5 kV operating voltage and 0.30 A beam current, the output power of 360 W, the efficiency of 7.27%, the gain of 38.6 dB, and the 3 dB bandwidth of 500 MHz are predicted. The output properties of the EIK show great stability with the effective suppression of oscillation and mode competition. Moreover, small-signal theory analysis and 1D code AJDISK calculations are carried out to verify the results of 3D PIC simulations. A close agreement among the three methods proves the relative validity and the reliability of the designed EIK. Thus, it is indicated that the EIK with unequal-length slots has potential for power improvement and bandwidth extension.

  18. Medium Power 352 MHZ solid state pulsed RF amplifiers for the CERN LINAC4 Project

    CERN Document Server

    Broere, J; Gómez Martínez, Y; Rossi, M

    2011-01-01

    Economic, modular and highly linear pulsed RF amplifiers have recently been developed to be used for the three buncher cavities in the CERN Linac4. The amplifiers are water-cooled and can provide up to 33 kW pulsed RF Power, 1.5 ms pulse length and 50 Hz repetition rate. Furthermore a 60 kW unit is under construction to provide the required RF Power for the debuncher cavity. The concept is based on 1.2 kW RF power modules using the latest 6th generation LDMOS technology. For integration into the CERN control environment the amplifiers have an internal industrial controller, which will provide easy control and extended diagnostic functions. This paper describes the construction, performance, including linearity, phase stability and EMC compliance tests

  19. Economic analysis of extended cycles in the Laguna Verde nuclear power plant

    International Nuclear Information System (INIS)

    Hernandez N, H.; Hernandez M, J.L.; Francois L, J.L.

    2004-01-01

    The present work presents a preliminary analysis of economic type of extended cycles of operation of the Unit One in the Laguna Verde nuclear power plant. It is analysed an equilibrium cycle of 18 months firstly, with base to the Plan of Use of Energy of the Federal Commission of Electricity, being evaluated the cost of the energy until the end of the useful life of the plant. Later on an alternative recharge scenario is presented with base to an equilibrium cycle of 24 months, implemented to the beginning of the cycle 11, without considering transition cycles. It is added in both cycles the cost of the substitution energy, considering the unitary cost of the fuel of a dual thermoelectric power station of 350 M We and evaluating in each operation cycle, in both scenarios, the value of the substitution energy. The results show that a reduction of the days of recharge in the cycle of 24 months could make this option but favorable economically. The duration of the period of recharge rebounds in considerable grade in the cost of energy generation for concept of fuel. (Author)

  20. Pen harvester for powering a pulse rate sensor

    International Nuclear Information System (INIS)

    Bedekar, Vishwas; Oliver, Josiah; Priya, Shashank

    2009-01-01

    Rapid developments in the area of micro-sensors for various applications such as structural health monitoring, bio-chemical sensors and pressure sensors have increased the demand for portable, low cost, high efficiency energy harvesting devices. In this paper, we describe the scheme for powering a pulse rate sensor with a vibration energy harvester integrated inside a pen commonly carried by humans in the pocket close to the heart. Electromagnetic energy harvesting was selected in order to achieve high power at lower frequencies. The prototype pen harvester was found to generate 3 mW at 5 Hz and 1 mW at 3.5 Hz operating under displacement amplitude of 16 mm (corresponding to an acceleration of approximately 1.14 g rms at 5 Hz and 0.56 g rms at 3.5 Hz, respectively). A comprehensive mathematical modelling and simulations were performed in order to optimize the performance of the vibration energy harvester. The integrated pen harvester prototype was found to generate continuous power of 0.46-0.66 mW under normal human actions such as jogging and jumping which is enough for a small scale pulse rate sensor.

  1. Analysis and Design of Bi-Directional DC-DC Converter in the Extended Run Time DC UPS System Based on Fuel Cell and Supercapacitor

    DEFF Research Database (Denmark)

    Zhang, Zhe; Thomsen, Ole Cornelius; Andersen, Michael A. E.

    2009-01-01

    Abstract-In this paper, an extended run time DC UPS system structure with fuel cell and supercapacitor is investigated. A wide input range bi-directional dc-dc converter is described along with the phase-shift modulation scheme and phase-shift with duty cycle control, in different modes. The deli......Abstract-In this paper, an extended run time DC UPS system structure with fuel cell and supercapacitor is investigated. A wide input range bi-directional dc-dc converter is described along with the phase-shift modulation scheme and phase-shift with duty cycle control, in different modes...

  2. 18 CFR 300.20 - Interim acceptance and review of Bonneville Power Administration rates.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Interim acceptance and review of Bonneville Power Administration rates. 300.20 Section 300.20 Conservation of Power and Water... Director of the Office of Energy Market Regulation; or (ii) Deny the Administrator's interim rate request...

  3. A Low-Power WLAN Communication Scheme for IoT WLAN Devices Using Wake-Up Receivers

    Directory of Open Access Journals (Sweden)

    Hanseul Hong

    2018-01-01

    Full Text Available In this paper, we propose a delay- and power-efficient, multi-user, low-power wireless local area network (WLAN communication scheme for Internet of Things (IoT WLAN devices. Extremely low-power operation is one of the key requirements of emerging IoT devices. However, the current duty-cycle-based power saving approach may incur large access delay times owing to the trade-offs between the power consumption and the access delay. In order to reduce this delay and enhance the power-saving performance, wake-up receiver-based schemes have been proposed. However, because wake-up receiver-based schemes do not consider multiuser operation in dense communication environments, large delays are inevitable in the case of multiuser operation. In order to provide extremely low-power operation and under 1-mW standby power with reduced delay, we employed the optimized multiuser transmission scheduling of IEEE 802.11ax in the proposed scheme and proper enhanced distributed channel access (EDCA parameter settings. This is with the aim to reduce the delay caused by long wake-up times, and to avoid collisions caused by simultaneous transmission in uplink multiuser scenario. By using the proposed scheme, simultaneous IoT communication with multiple mobile IoT devices is possible while providing low-power operation. Simulation results verified the outstanding delay performance of the proposed scheme.

  4. High-speed extended-term time-domain simulation for online cascading analysis of power system

    Science.gov (United States)

    Fu, Chuan

    A high-speed extended-term (HSET) time domain simulator (TDS), intended to become a part of an energy management system (EMS), has been newly developed for use in online extended-term dynamic cascading analysis of power systems. HSET-TDS includes the following attributes for providing situational awareness of high-consequence events: (i) online analysis, including n-1 and n-k events, (ii) ability to simulate both fast and slow dynamics for 1-3 hours in advance, (iii) inclusion of rigorous protection-system modeling, (iv) intelligence for corrective action ID, storage, and fast retrieval, and (v) high-speed execution. Very fast on-line computational capability is the most desired attribute of this simulator. Based on the process of solving algebraic differential equations describing the dynamics of power system, HSET-TDS seeks to develop computational efficiency at each of the following hierarchical levels, (i) hardware, (ii) strategies, (iii) integration methods, (iv) nonlinear solvers, and (v) linear solver libraries. This thesis first describes the Hammer-Hollingsworth 4 (HH4) implicit integration method. Like the trapezoidal rule, HH4 is symmetrically A-Stable but it possesses greater high-order precision (h4 ) than the trapezoidal rule. Such precision enables larger integration steps and therefore improves simulation efficiency for variable step size implementations. This thesis provides the underlying theory on which we advocate use of HH4 over other numerical integration methods for power system time-domain simulation. Second, motivated by the need to perform high speed extended-term time domain simulation (HSET-TDS) for on-line purposes, this thesis presents principles for designing numerical solvers of differential algebraic systems associated with power system time-domain simulation, including DAE construction strategies (Direct Solution Method), integration methods(HH4), nonlinear solvers(Very Dishonest Newton), and linear solvers(SuperLU). We have

  5. Power/knowledge and natural resource management

    NARCIS (Netherlands)

    Assche, Van Kristof; Beunen, Raoul; Duineveld, Martijn; Gruezmacher, Monica

    2017-01-01

    In this paper, we present a conceptual framework extending Foucaultian insights on the relations between power and knowledge to link up with current insights into studies of natural resource management (NRM) and more broadly environmental studies. We classify discourses in NRM according to

  6. Spacecraft Angular Rates Estimation with Gyrowheel Based on Extended High Gain Observer

    Directory of Open Access Journals (Sweden)

    Xiaokun Liu

    2016-04-01

    Full Text Available A gyrowheel (GW is a kind of electronic electric-mechanical servo system, which can be applied to a spacecraft attitude control system (ACS as both an actuator and a sensor simultaneously. In order to solve the problem of two-dimensional spacecraft angular rate sensing as a GW outputting three-dimensional control torque, this paper proposed a method of an extended high gain observer (EHGO with the derived GW mathematical model to implement the spacecraft angular rate estimation when the GW rotor is working at large angles. For this purpose, the GW dynamic equation is firstly derived with the second kind Lagrange method, and the relationship between the measurable and unmeasurable variables is built. Then, the EHGO is designed to estimate and calculate spacecraft angular rates with the GW, and the stability of the designed EHGO is proven by the Lyapunov function. Moreover, considering the engineering application, the effect of measurement noise in the tilt angle sensors on the estimation accuracy of the EHGO is analyzed. Finally, the numerical simulation is performed to illustrate the validity of the method proposed in this paper.

  7. On-line extraction of the variance caused by burn-up in in-core three-dimensional power distribution

    International Nuclear Information System (INIS)

    Wang Yaqi; Luo Zhengpei; Li Fu; Liu Wenfeng

    2001-01-01

    In most of PWRs, the ex-core ion-chambers are the sole real-time sensors to respond to in-core power and its axial offset. However, the calibration coefficient of the ion-chambers depends on the (3D) power distribution and varies with the burn-up. People expect to know the variance in distribution caused by burn-up directly from the signals of ion-chambers. This expectation is not realized as yet, because an ion-chamber almost only responds to its nearest fuel assemblies. The authors then developed a two-step method for burn-up characteristic extraction: the harmonics synthesis method and harmonics' burn-up grouping. Using the extracted burn-up characteristics, the relationship between the readings of the ex-core ion-chambers and the in-core 3D power distribution is set up. Through the simulation on the heating reactor, the method of burn-up characteristic extraction is verified under engineering conditions. It is possible to on-line extract the variance caused by burn-up in 3D power distribution

  8. Energy efficiency of uninterruptible power supply systems (UPS); Projekt Energieeffizienz von USV-Anlagen

    Energy Technology Data Exchange (ETDEWEB)

    Schnyder, G.; Mauchle, P.

    2005-03-15

    This comprehensive final report for the Swiss Federal Office of Energy (SFOE) summarises and presents nine individual reports and documents concerning the topic of uninterruptible power supplies. The documents compiled for the Swiss Federal Office of Energy in earlier projects concerning the quality and energy efficiency of uninterruptible power supply (UPS) systems dating from 1998 to 2000 have been revised and expanded in collaboration with a UPS Systems 'Trendwatch' group. The central documents such as 'Optimised use of UPS systems', 'Measurement procedures for UPS systems', 'Label for UPS systems' and 'Quality/Energy matrix' have been translated into English. These documents form the basis for the international distribution of the studies and findings relating to the quality and energy efficiency of UPS systems. These results are to be distributed by both European as well as American commissions. A label and codes of conduct are being developed. The nine individual reports are summarised in separate abstracts also recorded in the ETDEWEB database.

  9. Start-up and commercial operation of the Laguna Verde power plants, unit 1

    International Nuclear Information System (INIS)

    Torres R, J.F.

    1991-01-01

    The main features of the unit 1 of the Laguna Verde Power Plant is presented as well as the phases of the start-up process. The process includes various steps and tests up to start the commercial operation. (author)

  10. The influence of data collection rate, containment size and data smoothing on containment Integrated Leak Rate Tests

    International Nuclear Information System (INIS)

    Wagner, W.T.; Langan, J.P.; Norris, W.E.; Lurie, D.

    1988-01-01

    Phase I of a U.S. Nuclear Regulatory Commission contract investigated nuclear power plant Integrated Leak Rate Tests (ILRTs) using data gathered at many domestic and foreign ILRTs. The study evaluated ILRTs with the ANS criteria (in ANSI/ANS-56.8-1987) and the proposed extended ANS criteria (in draft Regulatory Guide, Task MS 021-5, October 1986). The study considered (1) the effects of data collection rates on ILRT conclusions, (2) a possible relationship between containment size, data collection rate and ILRT duration, (3) the impact of the proposed extended ANS methodology on ILRTs, and (4) the influence of data smoothing on ILRT data. The study was performed using 20 sets of Type A and 17 sets of verification data

  11. Optimal power allocation of a sensor node under different rate constraints

    KAUST Repository

    Ayala Solares, Jose Roberto

    2012-06-01

    The optimal transmit power of a sensor node while satisfying different rate constraints is derived. First, an optimization problem with an instantaneous transmission rate constraint is addressed. Next, the optimal power is analyzed, but now with an average transmission rate constraint. The optimal solution for a class of fading channels, in terms of system parameters, is presented and a suboptimal solution is also proposed for an easier, yet efficient, implementation. Insightful asymptotical analysis for both schemes, considering a Rayleigh fading channel, are shown. Finally, the optimal power allocation for a sensor node in a cognitive radio environment is analyzed where an optimum solution for a class of fading channels is again derived. In all cases, numerical results are provided for either Rayleigh or Nakagami-m fading channels. © 2012 IEEE.

  12. Wind model for low frequency power fluctuations in offshore wind farms

    DEFF Research Database (Denmark)

    Vigueras-Rodríguez, A.; Sørensen, Poul Ejnar; Cutululis, Nicolaos Antonio

    2010-01-01

    of hours, taking into account the spectral correlation between different wind turbines. The modelling is supported by measurements from two large wind farms, namely Nysted and Horns Rev. Measurements from individual wind turbines and meteorological masts are used. Finally, the models are integrated......This paper investigates the correlation between the frequency components of the wind speed Power Spectral Density. The results extend an already existing power fluctuation model that can simulate power fluctuations of wind power on areas up to several kilometers and for time scales up to a couple...

  13. Time-variant power spectral analysis of heart-rate time series by ...

    Indian Academy of Sciences (India)

    Frequency domain representation of a short-term heart-rate time series (HRTS) signal is a popular method for evaluating the cardiovascular control system. The spectral parameters, viz. percentage power in low frequency band (%PLF), percentage power in high frequency band (%PHF), power ratio of low frequency to high ...

  14. High repetition rate tunable femtosecond pulses and broadband amplification from fiber laser pumped parametric amplifier.

    Science.gov (United States)

    Andersen, T V; Schmidt, O; Bruchmann, C; Limpert, J; Aguergaray, C; Cormier, E; Tünnermann, A

    2006-05-29

    We report on the generation of high energy femtosecond pulses at 1 MHz repetition rate from a fiber laser pumped optical parametric amplifier (OPA). Nonlinear bandwidth enhancement in fibers provides the intrinsically synchronized signal for the parametric amplifier. We demonstrate large tunability extending from 700 nm to 1500 nm of femtosecond pulses with pulse energies as high as 1.2 muJ when the OPA is seeded by a supercontinuum generated in a photonic crystal fiber. Broadband amplification over more than 85 nm is achieved at a fixed wavelength. Subsequent compression in a prism sequence resulted in 46 fs pulses. With an average power of 0.5 W these pulses have a peak-power above 10 MW. In particular, the average power and pulse energy scalability of both involved concepts, the fiber laser and the parametric amplifier, will enable easy up-scaling to higher powers.

  15. PUREX (SAMCONS) uninterruptible power supply (UPS) acceptance test procedure

    International Nuclear Information System (INIS)

    Blackaby, W.B.

    1997-01-01

    This Acceptance Test Procedure for the PUREX Surveillance and Monitoring and Control System (SAMCONS) Uninterruptible Power Supply (UPS) provides for testing and verifying the proper operation of the control panel alarms and trouble functions, the 6roper functioning of the AC inverter, ability of the battery supply to maintain the SAMCONS load for a minimum of two hours , and proper interaction with the SAMCONS Video graphic displays for alarm displays

  16. Operational experiences of the spallation neutron source superconducting linac and power ramp-up

    International Nuclear Information System (INIS)

    Kim, Sang-Ho

    2009-01-01

    The spallation neutron source (SNS) is a second generation pulsed neutron source and designed to provide a 1-GeV, 1.44-MW proton beam to a mercury target for neutron production. Since the commissioning of the accelerator complex in 2006, the SNS has started its operation for neutron production and beam power ramp-up has been in progress toward the design goal. All subsystems of the SNS were designed and developed for substantial improvements compared to existing accelerators because the design beam power is almost an order of magnitude higher compared to existing neutron facilities and the achievable neutron scattering performance will exceed present sources by more than a factor of 20 to 100. In this paper, the operational experiences with the SNS Superconducting Linac (SCL), Power Ramp-up Plan to reach the design goal and the Power Upgrade Plan (PUP) will be presented including machine, subsystem and beam related issues.

  17. Power plays: Elusive electricity goals still light up Ontario and Alberta leaders

    Energy Technology Data Exchange (ETDEWEB)

    Lunan, D.

    2002-10-07

    Experiences with electric industry deregulation in Alberta and Ontario are discussed. It appears that opening up the market to competition has not lived up to the expectations of its proponents of a paradise of plentiful cheap power, although neither is it a swamp of shortages and sky-rocketing prices (disregarding start-up glitches) as characterized by those opposed to privatization of the electric utilities. The paper describes the many ups and downs of the debut of the deregulated electric power market in both provinces, the surprising reluctance of investors to enter the market, the unexpected surge of prices during periods of high demand, the frustration and rising dissatisfaction of residential consumers, and the efforts of regulatory agencies to make adjustments and bring a degree of stability to the system. The consumer billing complaints have benefited at least one segment of industry: it created a profitable business for software developers, such as Calgary-based UtilityNet, who offer power management products to large industrial and commercial consumers that allow them to track energy purchases, monitor risk management initiatives and confirm actual electricity use against budgets and utility billings. UtilityNet is also preparing applications software designed to calculate and track greenhouse gas emissions and identify emission reduction opportunities. In general, large-scale users of electricity appear to have achieved some of the promised benefits; residential consumers have yet to experience any meaningful benefit from the announced advantages of competition.

  18. Determining the Exchange Rate: Purchasing Power Parity – PPP

    Directory of Open Access Journals (Sweden)

    Bangun WIDOYOKO

    2018-05-01

    Full Text Available This study aimed to examine the effect of inflation on the issue of exchange rate determination of the forward exchange rate on the exchange rate of RMB (Renminbi to Rupiah. Inflation has been chosen as an independent variable because of its close relation to PPP (purchasing power parity theory. Analyses in this research have used logistic analysis with time series data. The data that has been used include exchange rate data with the period 2007-2017 with a sample size of 132 data. The results of this study have shown that inflation is effective in determining the exchange rate.

  19. Mortality risk in a historical cohort of nuclear power plant workers in Germany: results from a second follow-up

    Energy Technology Data Exchange (ETDEWEB)

    Merzenich, Hiltrud; Troeltzsch, Katrin; Ruecker, Kai; Buncke, Johanna; Blettner, Maria [University Medical Center Mainz, Institute of Medical Biostatistics, Epidemiology and Informatics, Mainz (Germany); Hammer, Gael P. [University Medical Center Mainz, Institute of Medical Biostatistics, Epidemiology and Informatics, Mainz (Germany); Laboratoire National de Sante E.P., Registre Morphologique des Tumeurs, Dudelange (Luxembourg); Fehringer, Franz [Berufsgenossenschaft Energie Textil Elektro Medienerzeugnisse (BGETEM), Cologne (Germany)

    2014-05-15

    Possible health effects of low and protracted doses of ionizing radiation are relevant for persons who are exposed to an occupational context like nuclear industry workers. A historical cohort study was therefore conducted to examine mortality risks following occupational radiation exposure among 4,844 German nuclear power plant workers. This cohort included workers from ten nuclear power plants with an observational period from 1991 until 1997. The results of an enlarged cohort with 8,972 workers from all 17 nuclear power plants in West Germany are now available. During the extended follow-up period from 1991 to 2008, a total of 310 deaths among men were observed. The standardized mortality ratio (SMR) from all causes of deaths was estimated at 0.50 [95 % confidence interval (CI) 0.45-0.56]. A total of 126 deaths due to cancer occurred (SMR = 0.65; 95 % CI 0.51-0.82) and seven deaths due to leukemia (SMR = 1.23; 95 % CI 0.42-2.84). Overall, a reduced mortality compared to the general population of West Germany was observed indicating a healthy worker effect. In the dose-response analysis, no statistically significant risk due to ionizing radiation was seen. The hazard ratio (HR/mSv) for leukemia excluding chronic lymphocytic leukemia was estimated at 1.004 (95 % CI 0.997-1.011). In conclusion, the cohort is small and made up of young workers, most of whom were still employed at the end of the observational period in 2008. Results of the external analysis are difficult to interpret as influenced by a healthy worker effect. In the internal analysis, no excess of risk due to radiation was detected. (orig.)

  20. Mortality risk in a historical cohort of nuclear power plant workers in Germany: results from a second follow-up

    International Nuclear Information System (INIS)

    Merzenich, Hiltrud; Troeltzsch, Katrin; Ruecker, Kai; Buncke, Johanna; Blettner, Maria; Hammer, Gael P.; Fehringer, Franz

    2014-01-01

    Possible health effects of low and protracted doses of ionizing radiation are relevant for persons who are exposed to an occupational context like nuclear industry workers. A historical cohort study was therefore conducted to examine mortality risks following occupational radiation exposure among 4,844 German nuclear power plant workers. This cohort included workers from ten nuclear power plants with an observational period from 1991 until 1997. The results of an enlarged cohort with 8,972 workers from all 17 nuclear power plants in West Germany are now available. During the extended follow-up period from 1991 to 2008, a total of 310 deaths among men were observed. The standardized mortality ratio (SMR) from all causes of deaths was estimated at 0.50 [95 % confidence interval (CI) 0.45-0.56]. A total of 126 deaths due to cancer occurred (SMR = 0.65; 95 % CI 0.51-0.82) and seven deaths due to leukemia (SMR = 1.23; 95 % CI 0.42-2.84). Overall, a reduced mortality compared to the general population of West Germany was observed indicating a healthy worker effect. In the dose-response analysis, no statistically significant risk due to ionizing radiation was seen. The hazard ratio (HR/mSv) for leukemia excluding chronic lymphocytic leukemia was estimated at 1.004 (95 % CI 0.997-1.011). In conclusion, the cohort is small and made up of young workers, most of whom were still employed at the end of the observational period in 2008. Results of the external analysis are difficult to interpret as influenced by a healthy worker effect. In the internal analysis, no excess of risk due to radiation was detected. (orig.)

  1. Standard model extended by a heavy singlet: Linear vs. nonlinear EFT

    Energy Technology Data Exchange (ETDEWEB)

    Buchalla, G., E-mail: gerhard.buchalla@lmu.de; Catà, O.; Celis, A.; Krause, C.

    2017-04-15

    We consider the Standard Model extended by a heavy scalar singlet in different regions of parameter space and construct the appropriate low-energy effective field theories up to first nontrivial order. This top-down exercise in effective field theory is meant primarily to illustrate with a simple example the systematics of the linear and nonlinear electroweak effective Lagrangians and to clarify the relation between them. We discuss power-counting aspects and the transition between both effective theories on the basis of the model, confirming in all cases the rules and procedures derived in previous works from a bottom-up approach.

  2. Pengaruh Latihan Traditional Push Up, Plyometric Push Up, dan Incline Push Up Terhadap Kekuatan Otot Lengan, Power Otot Lengan, dan Daya Tahan Otot Lengan

    Directory of Open Access Journals (Sweden)

    Febriyan Dwi Cahyono

    2018-05-01

    Full Text Available Tujuan penelitian ini adalah untuk peningkatan performa fisik otot lengan siswa ekstrakulikuler putra SMAN 2 Lamongan yang memiliki kelemahan saat dilakukan evaluasi fisik. Empat puluh siswa sehat dengan melihat status gizi melalui indeks masa tubuh (IMT dipilih sesuai dengan kriteria dan dilakukan pretest dan pemeringkatan sehingga masuk dalam pengelompokan traditional push up, plyometric push up, incline push up dan kelompok kontrol. Push up 30 detik, push up 60 detik dan medicine ball test digunakan untuk mengukur peningkatan kinerja. Ketiga kelompok berpartisipasi dalam penelitian tiga hari dalam seminggu selama enam minggu dan menyelesaikan 18 sesi pelatihan, pada frekuensi 3 sesi per minggu. Hasil uji paired sample t-test dalam kelompok traditional push up menunjukkan pengaruh yang signifikan pada variabel kekuatan dan daya tahan, kelompok plyometric push up menunjukkan pengaruh yang signifikan pada variabel kekuatan dan power, dan kelompok incline push up menunjukkan pengaruh yang signifikan pada variabel kekuatan dan daya tahan.  Disimpulkan dari penelitian ini bahwa pelatihan traditional push up, plyometric push up dan incline push up ketiganya efektif untuk peningkatan kinerja tubuh bagian atas.

  3. To Solution of Classical Problem Pertaining to Magnetic Interference of Overhead Power Transmission Line on Extended Conducting Communications

    Directory of Open Access Journals (Sweden)

    V. I. Glushko

    2013-01-01

    Full Text Available The paper considers a problem pertaining to magnetic interference of overhead power transmission lines and high-voltage bus bars of electrical installations on extended conducting communications and secondary circuits of relay protection and automation. A simplified task solution has been obtained on the basis of the Carson integral approximation.

  4. The process of the start-up of a PWR nuclear power plant in the USA

    International Nuclear Information System (INIS)

    Rana, B.S.

    1977-01-01

    The procedure is described of putting into full operation the William B. Mc Guire nuclear power plant with two PWR reactors with an output of 2x3,411 MWt (2x1,220 MWe) supplied to the Duke Power Co. lock, stock and barrel. The basic specifications are shown of units I and II and the organization of start-up activities is described. The time schedule of preoperational and start-up tests is shown and testing is reviewed preceding the first fuel charge. Also described are tests related to the first start-up of a unit comprising the period of the first fuel charge, the initial critical state, low-power tests and tests with power gradually increased. In tests of the individual systems and components of the unit, operating regulations are verified and, if required, renewed, or new regulations are introduced. (B.S.)

  5. The Use of the UPS Systems in the CERN Power Distribution

    CERN Document Server

    Pedersen, J

    2000-01-01

    The un-interruptible power supply (UPS) provides an increased supply reliability. It provides a no-break commutation to a battery in case of mains fault, and it provides a defined time for shut-down of critical installations. UPS systems are in service all over CERN, mainly supplying computer systems, control systems and other systems linked to safety. For the LHC the systems protecting the machine in case of quenching of supraconducting elements will require practically fail-safe installations. The desired degree of reliability and availability will be achieved by the use of UPS systems, grouped to assure a sufficient level of redundancy.

  6. Achievable data rate in spectrum-sharing channels with variable-rate variable-power primary users

    KAUST Repository

    Yang, Yuli; Aï ssa, Sonia

    2012-01-01

    In this work, we propose a transmission strategy for secondary users (SUs) within a cognitive radio network where primary users (PUs) exploit variable-rate variable-power modulation. By monitoring the PU's transmissions, the SU adjusts its transmit

  7. New generation of compact high power disk lasers

    Science.gov (United States)

    Feuchtenbeiner, Stefanie; Zaske, Sebastian; Schad, Sven-Silvius; Gottwald, Tina; Kuhn, Vincent; Kumkar, Sören; Metzger, Bernd; Killi, Alexander; Haug, Patrick; Speker, Nicolai

    2018-02-01

    New technological developments in high power disk lasers emitting at 1030 nm are presented. These include the latest generation of TRUMPF's TruDisk product line offering high power disk lasers with up to 6 kW output power and beam qualities of up to 4 mm*mrad. With these compact devices a footprint reduction of 50% compared to the previous model could be achieved while at the same time improving robustness and increasing system efficiency. In the context of Industry 4.0, the new generation of TruDisk lasers features a synchronized data recording of all sensors, offering high-quality data for virtual analyses. The lasers therefore provide optimal hardware requirements for services like Condition Monitoring and Predictive Maintenance. We will also discuss its innovative and space-saving cooling architecture. It allows operation of the laser under very critical ambient conditions. Furthermore, an outlook on extending the new disk laser platform to higher power levels will be given. We will present a disk laser with 8 kW laser power out of a single disk with a beam quality of 5 mm*mrad using a 125 μm fiber, which makes it ideally suited for cutting and welding applications. The flexibility of the disk laser platform also enables the realization of a wide variety of beam guiding setups. As an example a new scheme called BrightLine Weld will be discussed. This technology allows for an almost spatter free laser welding process, even at high feed rates.

  8. Extending Spent Fuel Storage until Transport for Reprocessing or Disposal

    Energy Technology Data Exchange (ETDEWEB)

    Carlsen, Brett; Chiguer, Mustapha; Grahn, Per; Sampson, Michele; Wolff, Dietmar; Bevilaqua, Arturo; Wasinger, Karl; Saegusa, Toshiari; Seelev, Igor

    2016-09-01

    Spent fuel (SF) must be stored until an end point such as reprocessing or geologic disposal is imple-mented. Selection and implementation of an end point for SF depends upon future funding, legisla-tion, licensing and other factors that cannot be predicted with certainty. Past presumptions related to the availability of an end point have often been wrong and resulted in missed opportunities for properly informing spent fuel management policies and strategies. For example, dry cask storage systems were originally conceived to free up needed space in reactor spent fuel pools and also to provide SFS of up to 20 years until reprocessing and/or deep geological disposal became available. Hundreds of dry cask storage systems are now employed throughout the world and will be relied upon well beyond the originally envisioned design life. Given present and projected rates for the use of nuclear power coupled with projections for SF repro-cessing and disposal capacities, one concludes that SF storage will be prolonged, potentially for several decades. The US Nuclear Regulatory Commission has recently considered 300 years of storage to be appropriate for the characterization and prediction of ageing effects and ageing management issues associated with extending SF storage and subsequent transport. This paper encourages addressing the uncertainty associated with the duration of SF storage by de-sign – rather than by default. It suggests ways that this uncertainty may be considered in design, li-censing, policy, and strategy decisions and proposes a framework for safely extending spent fuel storage until SF can be transported for reprocessing or disposal – regardless of how long that may be. The paper however is not intended to either encourage or facilitate needlessly extending spent fuel storage durations. Its intent is to ensure a design and safety basis with sufficient margin to accommodate the full range of potential future scenarios. Although the focus is primarily on

  9. Atomic power plant and its operation method

    International Nuclear Information System (INIS)

    Yamamoto, Fumiaki; Higashio, Satoru.

    1986-01-01

    Purpose: To improve operation performance by partially restraining local over power in the axial power distribution of the reactor core by properly controlling the reactor pressure and furthermore by smoothly and properly performing reactor start-up operation in a short time while maintaining fuel integrity. Method: With the reactor pressure input to the pressure controller from the pressure detector, the valve opening of the main steam adjusting valve is adjusted so that the pressure will decrease when the reactor is started up. Also the adjusting valve is controlled so that the pressure will be lower than the set value of rated pressure, thus changing the axial distribution of void. In the meantime, with the stored state of xenon stored along with the increase of reactor power taken into consideration, the reactor pressure is increased as high as the rated value until the reactor power reaches to the rated power, thereby alleviating the local increase of reactor power without changing the whole reactor power and also enabling substantial reduction of reactor start-up time while maintaining reactor integrity. (Horiuchi, T.)

  10. The AP1000R nuclear power plant innovative features for extended station blackout mitigation

    International Nuclear Information System (INIS)

    Vereb, F.; Winters, J.; Schulz, T.; Cummins, E.; Oriani, L.

    2012-01-01

    Station Blackout (SBO) is defined as 'a condition wherein a nuclear power plant sustains a loss of all offsite electric power system concurrent with turbine trip and unavailability of all onsite emergency alternating current (AC) power system. Station blackout does not include the loss of available AC power to buses fed by station batteries through inverters or by alternate AC sources as defined in this section, nor does it assume a concurrent single failure or design basis accident...' in accordance with Reference 1. In this paper, the innovative features of the AP1000 plant design are described with their operation in the scenario of an extended station blackout event. General operation of the passive safety systems are described as well as the unique features which allow the AP1000 plant to cope for at least 7 days during station blackout. Points of emphasis will include: - Passive safety system operation during SBO - 'Fail-safe' nature of key passive safety system valves; automatically places the valve in a conservatively safe alignment even in case of multiple failures in all power supply systems, including normal AC and battery backup - Passive Spent Fuel Pool cooling and makeup water supply during SBO - Robustness of AP1000 plant due to the location of key systems, structures and components required for Safe Shutdown - Diverse means of supplying makeup water to the Passive Containment Cooling System (PCS) and the Spent Fuel Pool (SFP) through use of an engineered, safety-related piping interface and portable equipment, as well as with permanently installed onsite ancillary equipment. (authors)

  11. High rate gamma spectroscopy system for activation analysis of short-lived isomeric transitions

    Energy Technology Data Exchange (ETDEWEB)

    Westphall, G P [Atominstitut der Oesterreichischen Hochschulen, Vienna

    1976-07-15

    A high rate spectroscopy system specially suited for measurement of short-lived isomeric transitions is described, which, as part of a fast activation analysis facility at the TRIGA Mark II reactor, provides for automatic recording and immediate evaluation of gamma spectra taken from nuclides activated at stationary or pulsed reactor power. The system consists of a commercial de-coupled Ge(Li)-detector of 70 cm/sup 3/ modified for recycling operation for input rates in excess of 500000 c/s /sup 60/Co, a time variant trapezoidal shaping section and a fast constant dead-time ADC coupled to a programmed multichannel analyzer. Novel circuits for efficient pile-up rejection and time variant base line restoration extend the concept of gated integration up to count rates of more than 200000 c/s /sup 60/Co. Time-sequenced recording of spectra is performed by a minicomputer operated as a front-end processor of a larger laboratory computer, where final data processing takes place. New concepts for very simple and cost-effective implementation of multichannel analyzers by means of general purpose small computers are described.

  12. Linking Up : Public-Private Partnerships in Power Transmission in Africa

    OpenAIRE

    World Bank

    2017-01-01

    The 'Linking up: Public-Private Partnerships in Power Transmission in Africa' report examines private sector-led investments in transmission globally and how this approach is applicable in sub-Saharan Africa. The private sector has invested over US$25 billion in the generation sector in Africa, and across other regions, has also participated successfully in transmission networks in many co...

  13. Megawatt Power Level 120 GHz Gyrotrons for ITER Start-Up

    Energy Technology Data Exchange (ETDEWEB)

    Choi, E M; Marchewka, C; Mastovsky, I; Shapiro, M A; Sirigiri, J R; Temkin, R J [MIT - Plasma Science and Fusion Center, NW16-186, 167 Albany Street, Cambridge, MA 02139 (United States)

    2005-01-01

    We report operation of a 110 GHz gyrotron with 1.67 MW of output power measured in short pulses (3{mu}s) at an efficiency of 42% in the TE{sub 22,6} mode. We also present a preliminary design of a 1 MW, 120 GHz gyrotron for ITER start-up with an efficiency greater than 50%.

  14. Megawatt Power Level 120 GHz Gyrotrons for ITER Start-Up

    International Nuclear Information System (INIS)

    Choi, E M; Marchewka, C; Mastovsky, I; Shapiro, M A; Sirigiri, J R; Temkin, R J

    2005-01-01

    We report operation of a 110 GHz gyrotron with 1.67 MW of output power measured in short pulses (3μs) at an efficiency of 42% in the TE 22,6 mode. We also present a preliminary design of a 1 MW, 120 GHz gyrotron for ITER start-up with an efficiency greater than 50%

  15. Collaborative machining solution extends the operating life of a nuclear power plant

    International Nuclear Information System (INIS)

    Gilmore, Geoff; Becker, Andrew; Vandenberg, James

    2007-01-01

    Examination of a CANDU 6 nuclear power plant's steam generators during a scheduled maintenance outage revealed that the manway ports, part of the ASME Section III, Class 1 pressure boundary, needed repair. The port's inner cover gasket was not seating properly. Integrity was at risk. It was determined that this operation would required a specialized machine to successfully repair the manway port. The solution included the modification of a standard portable boring machine with a custom mounting option to enlarge the counterbore in the primary head shell from a round shape to an obround shape (76 mm of shell thickness, 16 mm radially). The shape change was needed to accommodate the new obround cover and gasket seal design. Once the new major shape was machined, the repair was finished with a Computer Numerically Controlled (CNC) machine developed by the service team to achieve the necessary gasket face location and sizing. The final result met all of the plant's expectations and was completed well within the time allotted during the maintenance shut down. This success was due to the positive partnership and collaboration of the service team and the machine tool manufacture working together to successfully extend the operating life of the nuclear power plant. (author)

  16. The photovoltaic-powered water desalination plant 'SORO' design, start up, operating experience

    Science.gov (United States)

    Neuhaeusser, G.; Mohn, J.; Petersen, G.

    Design features, operational parameters, and test results of a year of operation of the SORO prototype photovoltaic (PV) reverse osmosis salt water desalinization plant are described. Chemicals are added to the salt water to control the pH, prevent formation of compounds which could plug the flow system, and kill bacteria and slime which might grow in the solution. The water is pressurized and forced into contact with membranes which separate the fresh water from the brackish or sea water. The flow rate in the project was 180 l/h, with the main electrical energy load being the high pressure pump and the well pump. Batteries are charged before current is switched to power the desalinization system. The plant yielded 1.50 cu of fresh water/day and is concluded to be a viable design for scale-up to larger production figures, besides being economically competitive with solar desalinization installations where the salt content is 2000 ppm.

  17. Extended burnup demonstration: reactor fuel program. Pre-irradiation characterization and summary of pre-program poolside examinations. Big Rock Point extended burnup fuel

    International Nuclear Information System (INIS)

    Exarhos, C.A.; Van Swam, L.F.; Wahlquist, F.P.

    1981-12-01

    This report is a resource document characterizing the 64 fuel rods being irradiated at the Big Rock Point reactor as part of the Extended Burnup Demonstration being sponsored jointly by the US Department of Energy, Consumers Power Company, Exxon Nuclear Company, and General Public Utilities. The program entails extending the exposure of standard BWR fuel to a discharge average of 38,000 MWD/MTU to demonstrate the feasibility of operating fuel of standard design to levels significantly above current limits. The fabrication characteristics of the Big Rock Point EBD fuel are presented along with measurement of rod length, rod diameter, pellet stack height, and fuel rod withdrawal force taken at poolside at burnups up to 26,200 MWD/MTU. A review of the fuel examination data indicates no performance characteristics which might restrict the continued irradiation of the fuel

  18. Caught up in power: Exploring discursive frictions in community research

    Directory of Open Access Journals (Sweden)

    Cindy Hanson

    2016-09-01

    Full Text Available This article outlines the debate around the emancipatory claims of community-based research (CBR and identifies discursive frictions as a pivotal point upon which much of CBR practice revolves. Using a Foucauldian theoretical lens, we suggest that CBR is neither inherently emancipatory nor repressive, but that research outcomes are more often a product of power asymmetries in CBR relationships. To illustrate how power asymmetries in research relationships produce discursive frictions, several studies from our work and the literature are presented. The article provides examples of CBR relationships between the researcher and community members and relationships within the community to illustrate how power asymmetries and discursive frictions in these relationships dynamically influence research outcomes and thus alert researchers to the need to address power asymmetries not just before initiating CBR projects, but during CBR projects as well. We interrogate how power asymmetries and discursive frictions operate and are constructed in CBR in an attempt to highlight how research might be conducted more effectively and ethically. Finally, we indicate that some of the tensions and challenges associated with CBR might be ameliorated by the use of participatory facilitation methodologies, such as photo-voice and story circle discussion groups, that draw attention to power asymmetries and purposefully use more creative participatory tools to restructure power relationships and ultimately address the inequities that exist in the research process. Because CBR is continually caught up in power dynamics, we hope that highlighting some examples might offer an opportunity for increased dialogue and critical reflection on its claims of empowerment and emancipation. Keywords: discursive friction, Foucault, participatory methodologies, power asymmetries, research relationships, emancipatory research

  19. Gamma-ray spectrometric measurements of fission rate ratios between fresh and burnt fuel following irradiation in a zero-power reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kröhnert, H., E-mail: hanna.kroehnert@ensi.ch [Paul Scherrer Institut (PSI), CH-5232 Villigen (Switzerland); École Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne (Switzerland); Perret, G.; Murphy, M.F. [Paul Scherrer Institut (PSI), CH-5232 Villigen (Switzerland); Chawla, R. [Paul Scherrer Institut (PSI), CH-5232 Villigen (Switzerland); École Polytechnique Fédérale de Lausanne (EPFL), CH-1015 Lausanne (Switzerland)

    2013-01-11

    The gamma-ray activity from short-lived fission products has been measured in fresh and burnt UO{sub 2} fuel samples after irradiation in a zero-power reactor. For the first time, short-lived gamma-ray activity from fresh and burnt fuel has been compared and fresh-to-burnt fuel fission rate ratios have been derived. For the measurements, well characterized fresh and burnt fuel samples, with burn-ups up to 46 GWd/t, were irradiated in the zero-power research reactor PROTEUS. Fission rate ratios were derived based on the counting of high-energy gamma-rays above 2200 keV, in order to discriminate against the high intrinsic activity of the burnt fuel. This paper presents the measured fresh-to-burnt fuel fission rate ratios based on the {sup 142}La (2542 keV), {sup 89}Rb (2570 keV), {sup 138}Cs (2640 keV) and {sup 95}Y (3576 keV) high-energy gamma-ray lines. Comparisons are made with the results of Monte Carlo modeling of the experimental configuration, carried out using the MCNPX code. The measured fission rate ratios have 1σ uncertainties of 1.7–3.4%. The comparisons with calculated predictions show an agreement within 1–3σ, although there appears to be a slight bias (∼3%).

  20. Economic simplified boiling water reactor (ESBWR) response to an extended station blackout/ loss of all AC power

    International Nuclear Information System (INIS)

    Barrett, A.J.; Marquino, W.

    2013-01-01

    U.S. federal regulations require light water cooled nuclear power plants to cope with Station Blackout for a predetermined amount of time based on design factors for the plant. U.S. regulations define Station Blackout (SBO) as a loss of the offsite electric power system concurrent with turbine trip and unavailability of the onsite emergency AC power system. According to U.S. regulations, typically the coping period for an SBO is 4 hours and can be as long as 16 hours for currently operating BWR plants. Being able to cope with an SBO and loss of all AC power is required by international regulators as well. The U.S. licensing basis for the ESBWR is a coping period of 72 hours for an SBO based on U.S. NRC requirements for passive safety plants. In the event of an extended SBO (viz., greater than 72 hours), the ESBWR response shows that the design is able to cope with the event for at least 7 days without AC electrical power or operator action. ESBWR is a Generation III+ reactor design with an array of passive safety systems. The ESBWR primary success path for mitigation of an SBO event is the Isolation Condenser System (ICS). The ICS is a passive, closed loop, safety system that initiates automatically on a loss of power. Upon Station Blackout or loss of all AC power, the ICS begins removing decay heat from the Reactor Pressure Vessel (RPV) by (i) condensing the steam into water in heat exchangers located in pools of water above the containment, and (ii) transferring the decay heat to the atmosphere. The condensed water is then returned by gravity to cool the reactor again. The ICS alone is capable of maintaining the ESBWR in a safe shutdown condition after an SBO for an extended period. The fuel remains covered throughout the SBO event. The ICS is able to remove decay heat from the RPV for at least 7 days and maintains the reactor in a safe shutdown condition. The water level in the RPV remains well above the top of active fuel for the duration of the SBO event

  1. Minimal average consumption downlink base station power control strategy

    OpenAIRE

    Holtkamp H.; Auer G.; Haas H.

    2011-01-01

    We consider single cell multi-user OFDMA downlink resource allocation on a flat-fading channel such that average supply power is minimized while fulfilling a set of target rates. Available degrees of freedom are transmission power and duration. This paper extends our previous work on power optimal resource allocation in the mobile downlink by detailing the optimal power control strategy investigation and extracting fundamental characteristics of power optimal operation in cellular downlink. W...

  2. Does more government deficit raise the interest rate? Application of extended loanable funds model to Slovenia

    Directory of Open Access Journals (Sweden)

    Yu Hsing

    2009-12-01

    Full Text Available Extending the open-economy loanable funds model, this paper finds that more government deficit as a percentage of GDP does not lead to a higher government bond yield. In addition, a higher real Treasury bill rate, a higher expected inflation rate, a higher EU government bond yield, or an expected depreciation of the euro against the U.S. dollar would increase Slovenia’s long-term interest rate. The negative coefficient of the percentage change in real GDP is insignificant at the10% level. Applying the standard closed-economy or open-economy loanable funds model without including the world interest rate and the expected exchange rate, we find similar conclusions except that the positive coefficient of the ratio of the net capital inflow to GDP has a wrong sign and is insignificant at the 10% level.

  3. Scale-up of precipitation processes

    OpenAIRE

    Zauner, R.

    1999-01-01

    This thesis concerns the scale-up of precipitation processes aimed at predicting product particle characteristics. Although precipitation is widely used in the chemical and pharmaceutical industry, successful scale-up is difficult due to the absence of a validated methodology. It is found that none of the conventional scale-up criteria reported in the literature (equal power input per unit mass, equal tip speed, equal stirring rate) is capable of predicting the experimentally o...

  4. Extended follow-up of the CYCLOFA-LUNE trial comparing two sequential induction and maintenance treatment regimens for proliferative lupus nephritis based either on cyclophosphamide or on cyclosporine A.

    Science.gov (United States)

    Závada, J; Sinikka Pesicková, S; Rysavá, R; Horák, P; Hrncír, Z; Lukác, J; Rovensky, J; Vítová, J; Havrda, M; Rychlík, I; Böhmova, J; Vlasáková, V; Slatinská, J; Zadrazil, J; Olejárová, M; Tegzova, D; Tesar, V

    2014-01-01

    Objective To evaluate the extended follow-up of the CYCLOFA-LUNE trial, a randomized prospective trial comparing two sequential induction and maintenance treatment regimens for proliferative lupus nephritis based either on cyclophosphamide (CPH) or cyclosporine A (CyA). Patients and methods Data for kidney function and adverse events were collected by a cross-sectional survey for 38 of 40 patients initially randomized in the CYCLOFA-LUNE trial. Results The median follow-up time was 7.7 years (range 5.0-10.3). Rates of renal impairment and end-stage renal disease, adverse events (death, cardiovascular event, tumor, premature menopause) did not differ between the CPH and CyA group, nor did mean serum creatinine, 24 h proteinuria and SLICC damage score at last follow-up. Most patients in both groups were still treated with glucocorticoids, other immunosuppressant agents and blood pressure lowering drugs. Conclusion An immunosuppressive regimen based on CyA achieved similar clinical results to that based on CPH in the very long term.

  5. Deposition Rates of High Power Impulse Magnetron Sputtering: Physics and Economics

    Energy Technology Data Exchange (ETDEWEB)

    Anders, Andre

    2009-11-22

    Deposition by high power impulse magnetron sputtering (HIPIMS) is considered by some as the new paradigm of advanced sputtering technology, yet this is met with skepticism by others for the reported lower deposition rates, if compared to rates of more conventional sputtering of equal average power. In this contribution, the underlying physical reasons for the rate changes are discussed, including (i) ion return to the target and self-sputtering, (ii) the less-than-linear increase of the sputtering yield with increasing ion energy, (iii) yield changes due to the shift of species responsible for sputtering, (iv) changes to due to greater film density, limited sticking, and self-sputtering on the substrate, (v) noticeable power losses in the switch module, (vi) changes of the magnetic balance and particle confinement of the magnetron due to self-fields at high current, and (vii) superposition of sputtering and sublimation/evaporation for selected materials. The situation is even more complicated for reactive systems where the target surface chemistry is a function of the reactive gas partial pressure and discharge conditions. While most of these factors imply a reduction of the normalized deposition rate, increased rates have been reported for certain conditions using hot targets and less poisoned targets. Finally, some points of economics and HIPIMS benefits considered.

  6. Deposition rates of high power impulse magnetron sputtering: Physics and economics

    International Nuclear Information System (INIS)

    Anders, Andre

    2010-01-01

    Deposition by high power impulse magnetron sputtering (HIPIMS) is considered by some as the new paradigm of advanced sputtering technology, yet this is met with skepticism by others for the reported lower deposition rates, if compared to rates of more conventional sputtering of equal average power. In this contribution, the underlying physical reasons for the rate changes are discussed, including (i) ion return to the target and self-sputtering, (ii) the less-than-linear increase in the sputtering yield with increasing ion energy, (iii) yield changes due to the shift of species responsible for sputtering, (iv) changes due to greater film density, limited sticking, and self-sputtering on the substrate, (v) noticeable power losses in the switch module, (vi) changes in the magnetic balance and particle confinement of the magnetron due to self-fields at high current, and (vii) superposition of sputtering and sublimation/evaporation for selected materials. The situation is even more complicated for reactive systems where the target surface chemistry is a function of the reactive gas partial pressure and discharge conditions. While most of these factors imply a reduction in the normalized deposition rate, increased rates have been reported for certain conditions using hot targets and less poisoned targets. Finally, some points of economics and HIPIMS benefits are considered.

  7. Achievable rate of spectrum sharing cognitive radio systems over fading channels at low-power regime

    KAUST Repository

    Sboui, Lokman

    2014-11-01

    We study the achievable rate of cognitive radio (CR) spectrum sharing systems at the low-power regime for general fading channels and then for Nakagami fading. We formally define the low-power regime and present the corresponding closed-form expressions of the achievable rate lower bound under various types of interference and/or power constraints, depending on the available channel state information of the cross link (CL) between the secondary-user transmitter and the primary-user receiver. We explicitly characterize two regimes where either the interference constraint or the power constraint dictates the optimal power profile. Our framework also highlights the effects of different fading parameters on the secondary link (SL) ergodic achievable rate. We also study more realistic scenarios when there is either 1-bit quantized channel feedback from the CL alone or 2-bit feedback from both the CL and the SL and propose simple power control schemes and show that these schemes achieve the previously achieved rate at the low-power regime. Interestingly, we show that the low-power regime analysis provides a specific insight into the maximum achievable rate behavior of CR that has not been reported by previous studies.

  8. Power-Efficient Beacon Recognition Method Based on Periodic Wake-Up for Industrial Wireless Devices.

    Science.gov (United States)

    Song, Soonyong; Lee, Donghun; Jang, Ingook; Choi, Jinchul; Son, Youngsung

    2018-04-17

    Energy harvester-integrated wireless devices are attractive for generating semi-permanent power from wasted energy in industrial environments. The energy-harvesting wireless devices may have difficulty in their communication with access points due to insufficient power supply for beacon recognition during network initialization. In this manuscript, we propose a novel method of beacon recognition based on wake-up control to reduce instantaneous power consumption in the initialization procedure. The proposed method applies a moving window for the periodic wake-up of the wireless devices. For unsynchronized wireless devices, beacons are always located in the same positions within each beacon interval even though the starting offsets are unknown. Using these characteristics, the moving window checks the existence of the beacon associated withspecified resources in a beacon interval, checks again for neighboring resources at the next beacon interval, and so on. This method can reduce instantaneous power and generates a surplus of charging time. Thus, the proposed method alleviates the problems of power insufficiency in the network initialization. The feasibility of the proposed method is evaluated using computer simulations of power shortage in various energy-harvesting conditions.

  9. Energy, Electricity and Nuclear Power Estimates for the Period up to 2050. 2017 Ed

    International Nuclear Information System (INIS)

    2017-01-01

    Reference Data Series No. 1 (RDS-1) is an annual publication — currently in its thirty-seventh edition — containing estimates of energy, electricity and nuclear power trends up to the year 2050. RDS-1 starts with a summary of the status of nuclear power in IAEA Member States as of the end of 2016 based on statistical data collected by the IAEA’s Power Reactor Information System (PRIS). It then presents estimates of energy and electricity up to 2050 derived from various international studies, including the International Energy Agency’s World Energy Outlook 2016 and the United States Energy Information Administration’s International Energy Outlook 2016. The energy and electricity data for 2016 are estimated, as the latest information available from the United Nations Department of Economic and Social Affairs is for 2014. Population data originate from World Population Prospects (2015 revision), published by the Population Division of the United Nations Department of Economic and Social Affairs. The 2016 values again are estimates. As in previous editions of RDS-1, projections of nuclear power are presented as low and high estimates encompassing the uncertainties inherent in projecting trends. The projections are based on a critical review of (i) the global and regional energy, electricity and nuclear power projections made by other international organizations, (ii) national projections supplied by individual countries for a recent OECD Nuclear Energy Agency study and (iii) the estimates of the expert group participating in the IAEA’s yearly consultancy on nuclear capacity projections. The low and high estimates reflect contrasting, but not extreme, underlying assumptions on the different driving factors that have an impact on nuclear power deployment. These factors, and the ways they might evolve, vary from country to country. The estimates presented provide a plausible range of nuclear capacity growth by region and worldwide. They are not intended to be

  10. Government Debt and the Long-Term Interest Rate: Application of an Extended Open-Economy Loanable Funds Model to Poland

    OpenAIRE

    Yu Hsing

    2010-01-01

    This paper examines the behavior of the long-term interest rate in Poland based on a sample during 2001.Q1–2009.Q1. Both the demand for and supply of loanable funds are considered. Extending the openeconomy loanable funds model, this paper finds thatmore government debt as a percent of gdp leads to a higher long-term interest rate in Poland and that a higher real Treasury bill rate, more percent change in real GDP, a higher expected inflation rate, a higher world long-term interest rate, and ...

  11. Low infection rate after tumor hip arthroplasty for metastatic bone disease in a cohort treated with extended antibiotic prophylaxis

    DEFF Research Database (Denmark)

    Hettwer, Werner H; Horstmann, Peter Frederik; Hovgaard, Thea Bechmann

    2015-01-01

    tumor resection for metastatic bone disease during a 4-year period from 2010 to 2013 (n = 105 patients). Results. Intravenous antibiotic prophylaxis was administrated for an extended duration of a mean of 7.4 days. The overall infection rate was 3.6% (4/111 implants), infection free survival was 96...... suggest that extended postoperative antibiotic prophylaxis may reduce the risk of PJI in patients undergoing tumor resection and endoprosthetic replacement for metastatic bone disease associated impending or de facto pathologic fractures of the proximal femur.......Background. Compared to conventional hip arthroplasty, endoprosthetic reconstruction after tumor resection is associated with a substantially increased risk of periprosthetic joint infection (PJI), with reported rates of around 10% in a recent systematic review. The optimal duration of antibiotic...

  12. CERI says lower power rates still in the future

    International Nuclear Information System (INIS)

    Anon.

    2000-01-01

    The impact that consumers will encounter with the convergence of Alberta's natural gas and electric utility industry were discussed. It will take a few years of infrastructure improvements before lower rates and improved efficiencies will be realized. Electricity prices in Alberta are expected to increase until the next generating capacity is connected to the provincial power grid. In addition, consumer prices are increasing because of the province's reliance on imports from British Columbia to meet peak demand. In August 2000 the province held a controversial auction of its generating capacity. The auction raised little more than $1 billion to the balancing pool, well short of the $4 billion target. Two major power facilities, the Genesee and Sheerness, failed to attract any bids at all. Despite this, the government accepted the results of the auction and will move forward with its retail restructuring program which calls for the competitive power market to be in place on January 1, 2001. The five major bidders who acquired the right to market about 4,249 megawatts of generating capacity from eight generating units in Alberta are EPCOR Utilities Inc., ENMAX Energy Corp., Enron Canada Power Corp., TransCanada PipeLines Ltd., and Engage Energy. The Alberta government is in the process of finalizing details of how the raised funds will be used to offset the impact of electricity rates

  13. The rate coefficients of unimolecular reactions in the systems with power-law distributions

    Science.gov (United States)

    Yin, Cangtao; Guo, Ran; Du, Jiulin

    2014-08-01

    The rate coefficient formulae of unimolecular reactions are generalized to the systems with the power-law distributions based on nonextensive statistics, and the power-law rate coefficients are derived in the high and low pressure limits, respectively. The numerical analyses are made of the rate coefficients as functions of the ν-parameter, the threshold energy, the temperature and the number of degrees of freedom. We show that the new rate coefficients depend strongly on the ν-parameter different from one (thus from a Boltzmann-Gibbs distribution). Two unimolecular reactions, CH3CO→CH3+CO and CH3NC→CH3CN, are taken as application examples to calculate their power-law rate coefficients, which obtained with the ν-parameters slightly different from one can be exactly in agreement with all the experimental studies on these two reactions in the given temperature ranges.

  14. Mortality of aircraft maintenance workers exposed to trichloroethylene and other hydrocarbons and chemicals: extended follow up

    Science.gov (United States)

    Radican, Larry; Blair, Aaron; Stewart, Patricia; Wartenberg, Daniel

    2009-01-01

    Objective To extend follow-up of 14,455 workers from 1990 to 2000, and evaluate mortality risk from exposure to trichloroethylene (TCE) and other chemicals. Methods Multivariable Cox models were used to estimate relative risk for exposed vs. unexposed workers based on previously developed exposure surrogates. Results Among TCE exposed workers, there was no statistically significant increased risk of all-cause mortality (RR=1.04) or death from all cancers (RR=1.03). Exposure-response gradients for TCE were relatively flat and did not materially change since 1990. Statistically significant excesses were found for several chemical exposure subgroups and causes, and were generally consistent with the previous follow up. Conclusions Patterns of mortality have not changed substantially since 1990. While positive associations with several cancers were observed, and are consistent with the published literature, interpretation is limited due to the small numbers of events for specific exposures. PMID:19001957

  15. Reliability and Sensitivity of the Power Push-up Test for Upper-Body Strength and Power in 6-15-Year-Old Male Athletes.

    Science.gov (United States)

    Gillen, Zachary M; Miramonti, Amelia A; McKay, Brianna D; Jenkins, Nathaniel D M; Leutzinger, Todd J; Cramer, Joel T

    2018-01-01

    Gillen, ZM, Miramonti, AA, McKay, BD, Jenkins, NDM, Leutzinger, TJ, and Cramer, JT. Reliability and sensitivity of the power push-up test for upper-body strength and power in 6-15-year-old male athletes. J Strength Cond Res 32(1): 83-96, 2018-The power push-up (PPU) test is an explosive upper-body test performed on a force plate and is currently being used in high school football combines throughout the United States. The purpose of this study was to quantify the reliability of the PPU test based on age and starting position (knees vs. toes) in young athletes. Sixty-eight boys (mean ± SD; age = 10.8 ± 2.0 years) were tested twice over 5 days. Boys were separated by age as 6-9 years (n = 16), 10-11 years (n = 26), and 12-15 years (n = 26). The PPU test was performed on a force plate while rotating from the knees vs. the toes. Measurements were peak force (PF, N), peak rate of force development (pRFD, N·s), average power (AP, W), and peak power (PP, W). Intraclass correlation coefficients (ICC2,1), SEMs, coefficients of variation (CVs), and minimum detectable changes (MDCs) were calculated to quantify reliability and sensitivity. Peak force from the knees in 10-15-year-olds, PF from the toes in 12-15-year-olds, and pRFD from the knees and toes in 12-15-year-olds were comparably reliable (ICC ≥ 0.84). Neither power measurements (AP or PP) for any age group, nor any measurements (PF, pRFD, AP, or PP) for the 6-9-year-olds were comparably reliable (ICC ≤ 0.74). When considering the reliable variables, PF was greater in the 12-15-year-olds than in 10-11-year-olds (p ≤ 0.05). In addition, in 12-15-year-olds, PF and pRFD were greater from the knees than from the toes (p ≤ 0.05). For reasons largely attributable to growth and development, the PPU test may be a reliable (ICC ≥ 0.80) and sensitive (CV ≤ 19%) measure of upper-body strength (PF), whereas pRFD was also reliable (ICC ≥ 0.80), but less sensitive (CV = 30-38%) in 10-15-year-old male athletes.

  16. Pilot power based rate control in CDMA 2000 1x EV-DO Rev-A

    Institute of Scientific and Technical Information of China (English)

    LIU Xiao-feng; GU Jian; YANG Hong-wen

    2008-01-01

    This article proposes a new algorithm to improvethe rate control efficiency of enhanced reverse link mediumaccess control (RLMAC) in the code division multiple access(CDMA) lx EV-DO release A(Rev. A) system. The newalgorithm brings reverse access terminal (AT) pilot power tothe RLMAC rate control procedure and makes it easier for alow pilot power user to increase its data rate when the systemis slightly loaded and harder to decrease its date rate when thesystem is heavily loaded. Numerical results of system levelsimulations show that the new algorithm can bring highersystem throughput, lower AT transmission power, and lowersystem load.

  17. Behavioral modeling of microwave power amplifiers using a look up table method

    NARCIS (Netherlands)

    Shen, Y.; Gajadharsing, J.; Tauritz, J.L.

    2007-01-01

    The possibility of building a microwave power amplifier (PA) behavioral model based on the look-up table principle is investigated. The model so constructed avoids the difficulties in model structure selection and/or its parameter estimation.

  18. Determination of the in-core power and the average core temperature of low power research reactors using gamma dose rate measurements

    International Nuclear Information System (INIS)

    Osei Poku, L.

    2012-01-01

    Most reactors incorporate out-of-core neutron detectors to monitor the reactor power. An accurate relationship between the powers indicated by these detectors and actual core thermal power is required. This relationship is established by calibrating the thermal power. The most common method used in calibrating the thermal power of low power reactors is neutron activation technique. To enhance the principle of multiplicity and diversity of measuring the thermal neutron flux and/or power and temperature difference and/or average core temperature of low power research reactors, an alternative and complimentary method has been developed, in addition to the current method. Thermal neutron flux/Power and temperature difference/average core temperature were correlated with measured gamma dose rate. The thermal neutron flux and power predicted using gamma dose rate measurement were in good agreement with the calibrated/indicated thermal neutron fluxes and powers. The predicted data was also good agreement with thermal neutron fluxes and powers obtained using the activation technique. At an indicated power of 30 kW, the gamma dose rate measured predicted thermal neutron flux of (1* 10 12 ± 0.00255 * 10 12 ) n/cm 2 s and (0.987* 10 12 ± 0.00243 * 10 12 ) which corresponded to powers of (30.06 ± 0.075) kW and (29.6 ± 0.073) for both normal level of the pool water and 40 cm below normal levels respectively. At an indicated power of 15 kW, the gamma dose rate measured predicted thermal neutron flux of (5.07* 10 11 ± 0.025* 10 11 ) n/cm 2 s and (5.12 * 10 11 ±0.024* 10 11 ) n/cm 2 s which corresponded to power of (15.21 ± 0.075) kW and (15.36 ± 0.073) kW for both normal levels of the pool water and 40 cm below normal levels respectively. The power predicted by this work also compared well with power obtained from a three-dimensional neutronic analysis for GHARR-1 core. The predicted power also compares well with calculated power using a correlation equation obtained from

  19. Laboratory- and Field-Based Assessment of Maximal Aerobic Power of Elite Stand-Up Paddle-Board Athletes.

    Science.gov (United States)

    Schram, Ben; Hing, Wayne; Climstein, Mike

    2016-01-01

    Stand-up paddle boarding (SUP) is a rapidly growing sport and recreational activity for which only anecdotal evidence exists on its proposed health, fitness, and injury-rehabilitation benefits. 10 internationally and nationally ranked elite SUP athletes. Participants were assessed for their maximal aerobic power on an ergometer in a laboratory and compared with other water-based athletes. Field-based assessments were subsequently performed using a portable gas-analysis system, and a correlation between the 2 measures was performed. Maximal aerobic power (relative) was significantly higher (P = .037) when measured in the field with a portable gas-analysis system (45.48 ± 6.96 mL · kg(-1) · min(-1)) than with laboratory-based metabolic-cart measurements (43.20 ± 6.67 mL · kg(-1) · min(-1)). There was a strong, positive correlation (r = .907) between laboratory and field maximal aerobic power results. Significantly higher (P = .000) measures of SUP paddling speed were found in the field than with the laboratory ergometer (+42.39%). There were no significant differences in maximal heart rate between the laboratory and field settings (P = .576). The results demonstrate the maximal aerobic power representative of internationally and nationally ranked SUP athletes and show that SUP athletes can be assessed for maximal aerobic power in the laboratory with high correlation to field-based measures. The field-based portable gas-analysis unit has a tendency to consistently measure higher oxygen consumption. Elite SUP athletes display aerobic power outputs similar to those of other upper-limb-dominant elite water-based athletes (surfing, dragon-boat racing, and canoeing).

  20. High-power pre-chirp managed amplification of femtosecond pulses at high repetition rates

    International Nuclear Information System (INIS)

    Liu, Yang; Li, Wenxue; Zhao, Jian; Bai, Dongbi; Luo, Daping; Zeng, Heping

    2015-01-01

    Femtosecond pulses at 250 MHz repetition rate from a mode-locked fiber laser are amplified to high power in a pre-chirp managed amplifier. The experimental strategy offers a potential towards high-power ultrashort laser pulses at high repetition rates. By investigating the laser pulse evolution in the amplification processes, we show that self-similar evolution, finite gain bandwidth and mode instabilities determine pulse characteristics in different regimes. Further average power scaling is limited by the mode instabilities. Nevertheless, this laser system enables us to achieve sub-50 fs pulses with an average power of 93 W. (letter)

  1. Motivational impairment predicts functional remission in first-episode psychosis: 3-Year follow-up of the randomized controlled trial on extended early intervention.

    Science.gov (United States)

    Chang, Wing Chung; Kwong, Vivian Wing Yan; Or Chi Fai, Philip; Lau, Emily Sin Kei; Chan, Gloria Hoi Kei; Jim, Olivia Tsz Ting; Hui, Christy Lai Ming; Chan, Sherry Kit Wa; Lee, Edwin Ho Ming; Chen, Eric Yu Hai

    2018-02-01

    Functional remission represents an intermediate functional milestone toward recovery. Differential relationships of negative symptom sub-domains with functional remission in first-episode psychosis are understudied. We aimed to examine rate and predictors of functional remission in people with first-episode psychosis in the context of a 3-year follow-up of a randomized controlled trial comparing 1-year extension of early intervention (i.e. 3-year early intervention) with step-down psychiatric care (i.e. 2-year early intervention). A total of 160 participants were recruited upon completion of a 2-year specialized early intervention program for first-episode psychosis in Hong Kong and underwent a 1-year randomized controlled trial comparing 1-year extended early intervention with step-down care. Participants were followed up and reassessed 3 years after inclusion to the trial (i.e. 3-year follow-up). Functional remission was operationalized as simultaneous fulfillment of attaining adequate functioning (measured by Social and Occupational Functioning Scale and Role Functioning Scale) at 3-year follow-up and sustained employment in the last 6 months of 3-year study period. Negative symptom measure was delineated into amotivation (i.e. motivational impairment) and diminished expression (i.e. reduced affect and speech output). Data analysis was based on 143 participants who completed follow-up functional assessments. A total of 31 (21.7%) participants achieved functional remission status at 3-year follow-up. Multivariate regression analysis showed that lower levels of amotivation ( p = 0.010) and better functioning at study intake ( p = 0.004) independently predicted functional remission (Final model: Nagelkerke R 2  = 0.40, χ 2  = 42.9, p amotivation may represent a critical therapeutic target for functional remission attainment in early psychosis.

  2. Application of neural networks to validation of feedwater flow rate in a nuclear power plant

    International Nuclear Information System (INIS)

    Khadem, M.; Ipakchi, A.; Alexandro, F.J.; Colley, R.W.

    1993-01-01

    Feedwater flow rate measurement in nuclear power plants requires periodic calibration. This is due to the fact that the venturi surface condition of the feedwater flow rate sensor changes because of a chemical reaction between the surface coating material and the feedwater. Fouling of the venturi surface, due to this chemical reaction and the deposits of foreign materials, has been observed shortly after a clean venturi is put in operation. A fouled venturi causes an incorrect measurement of feedwater flow rate, which in turn results in an inaccurate calculation of the generated power. This paper presents two methods for verifying incipient and continuing fouling of the venturi of the feedwater flow rate sensors. Both methods are based on the use of a set of dissimilar process variables dynamically related to the feedwater flow rate variable. The first method uses a neural network to generate estimates of the feedwater flow rate readings. Agreement, within a given tolerance, of the feedwater flow rate instrument reading, and the corresponding neural network output establishes that the feedwater flow rate instrument is operating properly. The second method is similar to the first method except that the neural network predicts the core power which is calculated from measurements on the primary loop, rather than the feedwater flow rates. This core power is referred to the primary core power in this paper. A comparison of the power calculated from the feedwater flow measurements in the secondary loop, with the calculated and neural network predicted primary core power provides information from which it can be determined whether fouling is beginning to occur. The two methods were tested using data from the feedwater flow meters in the two feedwater flow loops of the TMI-1 nuclear power plant

  3. High power pulsed magnetron sputtering: A method to increase deposition rate

    International Nuclear Information System (INIS)

    Raman, Priya; McLain, Jake; Ruzic, David N; Shchelkanov, Ivan A.

    2015-01-01

    High power pulsed magnetron sputtering (HPPMS) is a state-of-the-art physical vapor deposition technique with several industrial applications. One of the main disadvantages of this process is its low deposition rate. In this work, the authors report a new magnetic field configuration, which produces deposition rates twice that of conventional magnetron's dipole magnetic field configuration. Three different magnet pack configurations are discussed in this paper, and an optimized magnet pack configuration for HPPMS that leads to a higher deposition rate and nearly full-face target erosion is presented. The discussed magnetic field produced by a specially designed magnet assembly is of the same size as the conventional magnet assembly and requires no external fields. Comparison of deposition rates with different power supplies and the electron trapping efficiency in complex magnetic field arrangements are discussed

  4. Initiating Event Rates at U.S. Nuclear Power Plants. 1988 - 2013

    International Nuclear Information System (INIS)

    Schroeder, John A.; Bower, Gordon R.

    2014-01-01

    Analyzing initiating event rates is important because it indicates performance among plants and also provides inputs to several U.S. Nuclear Regulatory Commission (NRC) risk-informed regulatory activities. This report presents an analysis of initiating event frequencies at U.S. commercial nuclear power plants since each plant's low-power license date. The evaluation is based on the operating experience from fiscal year 1988 through 2013 as reported in licensee event reports. Engineers with nuclear power plant experience staff reviewed each event report since the last update to this report for the presence of valid scrams or reactor trips at power. To be included in the study, an event had to meet all of the following criteria: includes an unplanned reactor trip (not a scheduled reactor trip on the daily operations schedule), sequence of events starts when reactor is critical and at or above the point of adding heat, occurs at a U.S. commercial nuclear power plant (excluding Fort St. Vrain and LaCrosse), and is reported by a licensee event report. This report displays occurrence rates (baseline frequencies) for the categories of initiating events that contribute to the NRC's Industry Trends Program. Sixteen initiating event groupings are trended and displayed. Initiators are plotted separately for initiating events with different occurrence rates for boiling water reactors and pressurized water reactors. p-values are given for the possible presence of a trend over the most recent 10 years.

  5. The active control strategy on the output power for photovoltaic-storage systems based on extended PQ-QV-PV Node

    Science.gov (United States)

    Xu, Chen; Zhou, Bao-Rong; Zhai, Jian-Wei; Zhang, Yong-Jun; Yi, Ying-Qi

    2017-05-01

    In order to solve the problem of voltage exceeding specified limits and improve the penetration of photovoltaic in distribution network, we can make full use of the active power regulation ability of energy storage(ES) and the reactive power regulation ability of grid-connected photovoltaic inverter to provide support of active power and reactive power for distribution network. A strategy of actively controlling the output power for photovoltaic-storage system based on extended PQ-QV-PV node by analyzing the voltage regulating mechanism of point of commom coupling(PCC) of photovoltaic with energy storage(PVES) by controlling photovoltaic inverter and energy storage. The strategy set a small wave range of voltage to every photovoltaic by making the type of PCC convert among PQ, PV and QV. The simulation results indicate that the active control method can provide a better solution to the problem of voltage exceeding specified limits when photovoltaic is connectted to electric distribution network.

  6. Reactor core flow rate control system

    International Nuclear Information System (INIS)

    Sakuma, Hitoshi; Tanikawa, Naoshi; Takahashi, Toshiyuki; Miyakawa, Tetsuya.

    1996-01-01

    When an internal pump is started by a variable frequency power source device, if magnetic fields of an AC generator are introduced after the rated speed is reached, neutron flux high scram occurs by abrupt increase of a reactor core flow rate. Then, in the present invention, magnetic fields for the AC generator are introduced at a speed previously set at which the fluctuation range of the reactor core flow rate (neutron flux) by the start up of the internal pump is within an allowable value. Since increase of the speed of the internal pump upon its start up is suppressed to determine the change of the reactor core flow rate within an allowable range, increase of neutron fluxes is suppressed to enable stable start up. Then, since transition boiling of fuels caused by abrupt decrease of the reactor core flow rate upon occurrence of abnormality in an external electric power system is prevented, and the magnetic fields for the AC generator are introduced in such a manner to put the speed increase fluctuation range of the internal pump upon start up within an allowable value, neutron flux high scram is not caused to enable stable start-up. (N.H.)

  7. Quantacell: powerful charging of quantum batteries

    International Nuclear Information System (INIS)

    Binder, Felix C; Vinjanampathy, Sai; Modi, Kavan; Goold, John

    2015-01-01

    We study the problem of charging a quantum battery in finite time. We demonstrate an analytical optimal protocol for the case of a single qubit. Extending this analysis to an array of N qubits, we demonstrate that an N-fold advantage in power per qubit can be achieved when global operations are permitted. The exemplary analytic argument for this quantum advantage in the charging power is backed up by numerical analysis using optimal control techniques. It is demonstrated that the quantum advantage for power holds when, with cyclic operation in mind, initial and final states are required to be separable. (paper)

  8. The impact of phone calls on follow-up rates in an online depression prevention study

    Directory of Open Access Journals (Sweden)

    R.F. Muñoz

    2017-06-01

    Conclusions: Adding phone call contacts to email reminders and monetary incentives did increase follow-up rates. However, the rate of response to follow-up was low and the number of phone calls required to achieve one completed follow-up raises concerns about the utility of adding phone calls. We also discuss difficulties with using financial incentives and their implications.

  9. High-Power Electron Accelerators for Space (and other) Applications

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Dinh Cong [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Lewellen, John W. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2016-05-23

    This is a presentation on high-power electron accelerators for space and other applications. The main points covered are: electron beams for space applications, new designs of RF accelerators, high-power high-electron mobility transistors (HEMT) testing, and Li-ion battery design. In summary, the authors have considered a concept of 1-MeV electron accelerator that can operate up to several seconds. This concept can be extended to higher energy to produce higher beam power. Going to higher beam energy requires adding more cavities and solid-state HEMT RF power devices. The commercial HEMT have been tested for frequency response and RF output power (up to 420 W). Finally, the authors are testing these HEMT into a resonant load and planning for an electron beam test in FY17.

  10. Nonlinear detection for a high rate extended binary phase shift keying system.

    Science.gov (United States)

    Chen, Xian-Qing; Wu, Le-Nan

    2013-03-28

    The algorithm and the results of a nonlinear detector using a machine learning technique called support vector machine (SVM) on an efficient modulation system with high data rate and low energy consumption is presented in this paper. Simulation results showed that the performance achieved by the SVM detector is comparable to that of a conventional threshold decision (TD) detector. The two detectors detect the received signals together with the special impacting filter (SIF) that can improve the energy utilization efficiency. However, unlike the TD detector, the SVM detector concentrates not only on reducing the BER of the detector, but also on providing accurate posterior probability estimates (PPEs), which can be used as soft-inputs of the LDPC decoder. The complexity of this detector is considered in this paper by using four features and simplifying the decision function. In addition, a bandwidth efficient transmission is analyzed with both SVM and TD detector. The SVM detector is more robust to sampling rate than TD detector. We find that the SVM is suitable for extended binary phase shift keying (EBPSK) signal detection and can provide accurate posterior probability for LDPC decoding.

  11. Nonlinear Detection for a High Rate Extended Binary Phase Shift Keying System

    Directory of Open Access Journals (Sweden)

    Le-Nan Wu

    2013-03-01

    Full Text Available The algorithm and the results of a nonlinear detector using a machine learning technique called support vector machine (SVM on an efficient modulation system with high data rate and low energy consumption is presented in this paper. Simulation results showed that the performance achieved by the SVM detector is comparable to that of a conventional threshold decision (TD detector. The two detectors detect the received signals together with the special impacting filter (SIF that can improve the energy utilization efficiency. However, unlike the TD detector, the SVM detector concentrates not only on reducing the BER of the detector, but also on providing accurate posterior probability estimates (PPEs, which can be used as soft-inputs of the LDPC decoder. The complexity of this detector is considered in this paper by using four features and simplifying the decision function. In addition, a bandwidth efficient transmission is analyzed with both SVM and TD detector. The SVM detector is more robust to sampling rate than TD detector. We find that the SVM is suitable for extended binary phase shift keying (EBPSK signal detection and can provide accurate posterior probability for LDPC decoding.

  12. The AP1000{sup R} nuclear power plant innovative features for extended station blackout mitigation

    Energy Technology Data Exchange (ETDEWEB)

    Vereb, F.; Winters, J.; Schulz, T.; Cummins, E.; Oriani, L. [Westinghouse Electric Company LLC, 1000 Westinghouse Drive, Cranberry Township, PA 16066 (United States)

    2012-07-01

    Station Blackout (SBO) is defined as 'a condition wherein a nuclear power plant sustains a loss of all offsite electric power system concurrent with turbine trip and unavailability of all onsite emergency alternating current (AC) power system. Station blackout does not include the loss of available AC power to buses fed by station batteries through inverters or by alternate AC sources as defined in this section, nor does it assume a concurrent single failure or design basis accident...' in accordance with Reference 1. In this paper, the innovative features of the AP1000 plant design are described with their operation in the scenario of an extended station blackout event. General operation of the passive safety systems are described as well as the unique features which allow the AP1000 plant to cope for at least 7 days during station blackout. Points of emphasis will include: - Passive safety system operation during SBO - 'Fail-safe' nature of key passive safety system valves; automatically places the valve in a conservatively safe alignment even in case of multiple failures in all power supply systems, including normal AC and battery backup - Passive Spent Fuel Pool cooling and makeup water supply during SBO - Robustness of AP1000 plant due to the location of key systems, structures and components required for Safe Shutdown - Diverse means of supplying makeup water to the Passive Containment Cooling System (PCS) and the Spent Fuel Pool (SFP) through use of an engineered, safety-related piping interface and portable equipment, as well as with permanently installed onsite ancillary equipment. (authors)

  13. Effect of active warm-up duration on morning short-term maximal performance during Ramadan.

    Science.gov (United States)

    Baklouti, Hana; Chtourou, Hamdi; Aloui, Asma; Chaouachi, Anis; Souissi, Nizar

    2015-01-01

    To examine the effect of active warm-up duration on short-term maximal performance assessed during Ramadan in the morning. Twelve healthy active men performed four Wingate tests for measurement of peak power and mean power before and during Ramadan at 09:00 a.m. The tests were performed on separate days, after either a 5-min or a 15-min warm-up. The warm-up consisted in pedaling at 50% of the power output obtained at the last stage of a submaximal multistage cycling test. Oral temperature was measured at rest and after warming-up. Furthermore, ratings of perceived exertion were obtained immediately after the Wingate test. Oral temperature was higher after the 15-min warm-up than the 5-min warm-up throughout the study. Moreover, peak power and mean power were higher after the 15-min warm-up than the 5-min warm-up before Ramadan. However, during Ramadan, there was no significant difference between the two warm-up durations. In addition, ratings of perceived exertion were higher after the 15-min warm-up than the 5-min warm-up only during Ramadan. There is no need to prolong the warm-up period before short-term maximal exercise performed during Ramadan in the morning.

  14. Regional economic impacts of changes in electricity rates resulting from Western Area Power Administration`s power marketing alternatives

    Energy Technology Data Exchange (ETDEWEB)

    Allison, T.; Griffes, P.; Edwards, B.K.

    1995-03-01

    This technical memorandum describes an analysis of regional economic impacts resulting from changes in retail electricity rates due to six power marketing programs proposed by Western Area Power Administration (Western). Regional economic impacts of changes in rates are estimated in terms of five key regional economic variables: population, gross regional product, disposable income, employment, and household income. The REMI (Regional Impact Models, Inc.) and IMPLAN (Impact Analysis for Planning) models simulate economic impacts in nine subregions in the area in which Western power is sold for the years 1993, 2000, and 2008. Estimates show that impacts on aggregate economic activity in any of the subregions or years would be minimal for three reasons. First, the utilities that buy power from Western sell only a relatively small proportion of the total electricity sold in any of the subregions. Second, reliance of Western customers on Western power is fairly low in each subregion. Finally, electricity is not a significant input cost for any industry or for households in any subregion.

  15. Safety margin evaluation concepts for plant Up rates and life extension. Results of the OECD/NEA/CSNI working group on Safety Margin Action Plan (SMAP)

    International Nuclear Information System (INIS)

    Belac, J

    2006-01-01

    This presentation summarizes results of the OECD/NEA/CSNI working group on Safety Margin Action Plan (SMAP) aimed to develop generalized safety margin concept and means of its quantification for the process of evaluating plant safety in the frame of plant life extension and power up rating activities to be used by OECD member countries. (author)

  16. Rate-Optimized Power Allocation for DF-Relayed OFDM Transmission under Sum and Individual Power Constraints

    Directory of Open Access Journals (Sweden)

    Vandendorpe Luc

    2009-01-01

    Full Text Available We consider an OFDM (orthogonal frequency division multiplexing point-to-point transmission scheme which is enhanced by means of a relay. Symbols sent by the source during a first time slot may be (but are not necessarily retransmitted by the relay during a second time slot. The relay is assumed to be of the DF (decode-and-forward type. For each relayed carrier, the destination implements maximum ratio combining. Two protocols are considered. Assuming perfect CSI (channel state information, the paper investigates the power allocation problem so as to maximize the rate offered by the scheme for two types of power constraints. Both cases of sum power constraint and individual power constraints at the source and at the relay are addressed. The theoretical analysis is illustrated through numerical results for the two protocols and both types of constraints.

  17. Loss and thermal model for power semiconductors including device rating information

    DEFF Research Database (Denmark)

    Ma, Ke; Bahman, Amir Sajjad; Beczkowski, Szymon

    2014-01-01

    The electrical loading and device rating are both important factors that determine the loss and thermal behaviors of power semiconductor devices. In the existing loss and thermal models, only the electrical loadings are focused and treated as design variables, while the device rating is normally...

  18. A Long-Distance RF-Powered Sensor Node with Adaptive Power Management for IoT Applications.

    Science.gov (United States)

    Pizzotti, Matteo; Perilli, Luca; Del Prete, Massimo; Fabbri, Davide; Canegallo, Roberto; Dini, Michele; Masotti, Diego; Costanzo, Alessandra; Franchi Scarselli, Eleonora; Romani, Aldo

    2017-07-28

    We present a self-sustained battery-less multi-sensor platform with RF harvesting capability down to -17 dBm and implementing a standard DASH7 wireless communication interface. The node operates at distances up to 17 m from a 2 W UHF carrier. RF power transfer allows operation when common energy scavenging sources (e.g., sun, heat, etc.) are not available, while the DASH7 communication protocol makes it fully compatible with a standard IoT infrastructure. An optimized energy-harvesting module has been designed, including a rectifying antenna (rectenna) and an integrated nano-power DC/DC converter performing maximum-power-point-tracking (MPPT). A nonlinear/electromagnetic co-design procedure is adopted to design the rectenna, which is optimized to operate at ultra-low power levels. An ultra-low power microcontroller controls on-board sensors and wireless protocol, to adapt the power consumption to the available detected power by changing wake-up policies. As a result, adaptive behavior can be observed in the designed platform, to the extent that the transmission data rate is dynamically determined by RF power. Among the novel features of the system, we highlight the use of nano-power energy harvesting, the implementation of specific hardware/software wake-up policies, optimized algorithms for best sampling rate implementation, and adaptive behavior by the node based on the power received.

  19. A Long-Distance RF-Powered Sensor Node with Adaptive Power Management for IoT Applications

    Directory of Open Access Journals (Sweden)

    Matteo Pizzotti

    2017-07-01

    Full Text Available We present a self-sustained battery-less multi-sensor platform with RF harvesting capability down to −17 dBm and implementing a standard DASH7 wireless communication interface. The node operates at distances up to 17 m from a 2 W UHF carrier. RF power transfer allows operation when common energy scavenging sources (e.g., sun, heat, etc. are not available, while the DASH7 communication protocol makes it fully compatible with a standard IoT infrastructure. An optimized energy-harvesting module has been designed, including a rectifying antenna (rectenna and an integrated nano-power DC/DC converter performing maximum-power-point-tracking (MPPT. A nonlinear/electromagnetic co-design procedure is adopted to design the rectenna, which is optimized to operate at ultra-low power levels. An ultra-low power microcontroller controls on-board sensors and wireless protocol, to adapt the power consumption to the available detected power by changing wake-up policies. As a result, adaptive behavior can be observed in the designed platform, to the extent that the transmission data rate is dynamically determined by RF power. Among the novel features of the system, we highlight the use of nano-power energy harvesting, the implementation of specific hardware/software wake-up policies, optimized algorithms for best sampling rate implementation, and adaptive behavior by the node based on the power received.

  20. In search of extendable conditions for cable environmental qualification in nuclear power plants

    International Nuclear Information System (INIS)

    Alshaketheep, Tariq; Sekimura, Naoto; Itoi, Tatsuya; Murakami, Kenta

    2016-01-01

    The environmental qualification (EQ) for cable insulators in nuclear power plants (NPPs) has been developed on the basis of the design basis accident (DBA) to prevent reactor core damage. However, the latest safety principles require extending the design concept to prepare the utilized equipment for scenarios after core damage. Thus, we propose a modification to the EQ for cables connecting utilized equipment at design extension conditions. This paper surveys all electrical components for accident management in boiling water reactor-4 (BWR-4), and identifies their connecting cables' functional category as low-voltage power, instrumentation, and control cables. The EQ temperature profile of these cables during the incident phase was addressed for extension. This required postulating maximum temperature environments according to accident scenarios, knowledge of cable integrity degradation, and their current evaluation by the EQ. To evaluate whether these environments are suitable stressors, heat testing was conducted on flame-retardant ethylene propylene rubber (FR-EPR)-insulated cables. On the basis of those results, we suggest a maximum primary peak temperature of the EQ temperature profile of 250degC. We also suggest increasing the primary peak period of the EQ temperature profile to 48 h without experiment, on the basis of inherent excessive margin for mechanical integrity during the ageing phase. (author)

  1. Localization of Manufacturing Capabilities in Setting Up Nuclear Power Plants

    International Nuclear Information System (INIS)

    Chadda, Sushil Kumar

    2011-01-01

    Nuclear renaissance is now imminent and is inevitable in view of rapidly increasing global warming concerns. A steep shift towards environmentally benign sources of energy remains an unavoidable choice as continents are warming up pushing seas into human habitation and disturbing global ecology. Accordingly, Indian government in its integrated energy policy document has planned for raising nuclear power capacity to generate 63 GWe by 2030. This envisages estimated investments of US$22 billion in the next 15 to 20 years. Setting up of nuclear energy generation capacity, however, remains a painstakingly slow process primarily due to complex, multidisciplinary efforts required to crank up a reactor. A robust supply chain remains key to expediting this process. In the light of this, it is critically important to ensure supply-chain for materials and components and putting in place cost effective project management to complete the projects on time and within the budgets. In this context, the participation of industries and their preparedness to meet the challenges are necessary. This would also require investments towards up gradation of manufacturing technology, training of manpower and mobilization of resources at the construction site. The industry would also need to enhance detailing and design engineering capabilities for the plants. It is only when such capabilities have been brought up that the possibilities of time-bound setting up of nuclear plants can be realized. In this paper, various issues with regard to project cost, regulatory and licensing, technology and gestation period etc for new build plants relevant to manufacturing industry are discussed. The plans for enhancing manufacturing capabilities for the critical path items of the project schedule with viable business, ensuring returns to stakeholders and financing and investment cycle are brought out. The various steps and initiatives being taken by Bharat Forge Ltd, the flagship company of Kalyani

  2. Construction, start-up and operation of Dukovany nuclear power plant

    International Nuclear Information System (INIS)

    Hornicek, Z.

    1989-01-01

    The Labor Safety Inspectorate have been supervising the construction of the Dukovany nuclear power plant since the construction start in 1977. It was found that in concreting the reactor building walls with concrete mixes, the regulations were not observed on the highest level for the concrete mix drop, and on the gap processing and concrete treatment when concreting was interrupted. Thus, concreting was halted until the conditions for concreting were met. Attention was focused on the protection of the hermetic casing from damage, which had very often happened. A number of shortcomings were detected in storing technology parts. The cleanliness was inspected of the facilities being assembled. The inspections also revealed shortcomings in sealed space tightness. The inspections of assembly and testing of facilities showed failures of the facilities themselves (control valves, electric motors, filter and pump sealing) and of the assembly process. Faults were also detected in electrical equipment. Only a very small part of the installation showed lifetime as specified by Decree 105/1982 Coll. laws on safety assurance in the nuclear power industry. Missing data in documentation led to delays in the start-up stages. The State Surveillance Body also inspected the results of equipment testing. Prior to physical start-up, all production facilities and buildings were inspected, labor safety was inspected for all personnel in communicating corridors, staircases, manholes and onservice and handling posts. Shortcomings were removed. The organization of assembly work was a considerable problem if staff from more organizations had to work together in the same workplace. A list of tasks is presented of State Surveillance Body in operation, maintenance, outages, repairs, and troubleshooting in a nuclear power plant. (J.B.)

  3. CERN Proton Synchrotronworking point Matrix for extended pole face winding powering scheme

    CERN Document Server

    Freyermuth, P; Delrieux, M; Genoud, H; Gilardoni, S; Hanke, K; Hans, O; Mataguez, S; Metral, G; Peters, F; Steerenberg, R; Vandorpe, B

    2010-01-01

    The CERN Proton Synchrotron has been continuously improving its beam performances since 1959. The working point parameters of the accelerator are mainly controlled by dedicated windings installed on the poles of the main combined function magnets. In 2007, the power supplies of these windings were renovated and extended from three to five independent groups, allowing exploration of new working point settings. This configuration offers the flexibility of several adjustment strategies such as leaving one current free or to control an additional physical parameter, like Q′′ h. A non-linear chromaticity measurement campaign, at different beam momenta, resulted in matrices defining the relationship between the five pole face winding currents and the four beam parameters Qh, Qv, h, and v. Each cell of these matrices was fitted against momentum. The final result is a single matrix as a function of beam momentum, which is now used by the operational software to trim the working point. This paper summarises this m...

  4. Independent review of the SaskPower rate proposal of August 2004 : final report

    International Nuclear Information System (INIS)

    Ewing, J.D.; Buhr, L.A.

    2004-01-01

    This paper presents an independent review of SaskPower's request for an increase in rates effective September 1, 2004 and September 1, 2005. With the exception of manufacturing customers, whose rate increase will be phased in over four years, these rate changes will result in a 9 per cent system average increase in 2004 and a 1.8 per cent system average increase in 2005. The report presents an introduction and description of the terms of reference for this review; a financial outlook and comparisons; system operational analysis; an analysis of expenditures; revenue requirement; cost of service issues; and rate design. The report also presents a summary and recommendations on cost of service and rate design issues. The report concluded that the scope of this review does not lend itself to a definitive conclusion on the appropriateness of the cost of service model and its application by SaskPower. Several areas needing further attention include: net fuel and purchased power allocations to different classes; allocation of rate base and in particular distribution rate base to various classes; target ratios for revenue to revenue requirements and the subsequent return on rate base percentages for each class; and demand/energy/customer components of revenue requirements compared to billing revenues. refs., 31 tabs., 1 fig., 6 appendices

  5. 18 CFR 284.505 - Market-based rates for storage providers without a market-power determination.

    Science.gov (United States)

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Market-based rates for storage providers without a market-power determination. 284.505 Section 284.505 Conservation of Power and... UNDER THE NATURAL GAS POLICY ACT OF 1978 AND RELATED AUTHORITIES Applications for Market-Based Rates for...

  6. Power loss benchmark of nine-switch converters in three-phase online-UPS application

    DEFF Research Database (Denmark)

    Qin, Zian; Loh, Poh Chiang; Blaabjerg, Frede

    2014-01-01

    Three-phase online-UPS is an appropriate application for the nine-switch converter, where its high voltage stress of the power device caused by the reduced switch feature can be relieved significantly. Its power loss and loss distribution still have the flexibility from the control point of view...... as parameters like modulation index and phase angle of the load are taken into account. The benchmark of power loss will become a guidance for the users to make best use of the advantages and bypass the disadvantages of nine-switch converters. The results are finally verified on a 1.5 kW prototype....

  7. Modeling and Model Predictive Power and Rate Control of Wireless Communication Networks

    Directory of Open Access Journals (Sweden)

    Cunwu Han

    2014-01-01

    Full Text Available A novel power and rate control system model for wireless communication networks is presented, which includes uncertainties, input constraints, and time-varying delays in both state and control input. A robust delay-dependent model predictive power and rate control method is proposed, and the state feedback control law is obtained by solving an optimization problem that is derived by using linear matrix inequality (LMI techniques. Simulation results are given to illustrate the effectiveness of the proposed method.

  8. Radiology-led Follow-up System for IVC Filters: Effects on Retrieval Rates and Times

    International Nuclear Information System (INIS)

    Lee, L.; Taylor, J.; Munneke, G.; Morgan, R.; Belli, A.-M.

    2012-01-01

    Purpose: Successful IVC filter retrieval rates fall with time. Serious complications have been reported following attempts to remove filters after 3–18 months. Failed retrieval may be associated with adverse clinical sequelae. This study explored whether retrieval rates are improved if interventional radiologists organize patient follow-up, rather than relying on the referring clinicians. Methods: Proactive follow-up of patients who undergo filter placement was implemented in May 2008. At the time of filter placement, a report was issued to the referring consultant notifying them of the advised timeframe for filter retrieval. Clinicians were contacted to arrange retrieval within 30 days. We compared this with our practice for the preceding year. Results: The numbers of filters inserted during the two time periods was similar, as were the numbers of retrieval attempts and the time scale at which they occurred. The rate of successful retrievals increased but not significantly. The major changes were better documentation of filter types and better clinical follow-up. After the change in practice, only one patient was lost to follow-up compared with six the preceding year. Conclusions: Although there was no significant improvement in retrieval rates, the proactive, radiology-led approach improved follow-up and documentation, ensuring that a clinical decision was made about how long the filter was required and whether retrieval should be attempted and ensuring that patients were not lost to follow-up.

  9. Multi-timescale power and energy assessment of lithium-ion battery and supercapacitor hybrid system using extended Kalman filter

    Science.gov (United States)

    Wang, Yujie; Zhang, Xu; Liu, Chang; Pan, Rui; Chen, Zonghai

    2018-06-01

    The power capability and maximum charge and discharge energy are key indicators for energy management systems, which can help the energy storage devices work in a suitable area and prevent them from over-charging and over-discharging. In this work, a model based power and energy assessment approach is proposed for the lithium-ion battery and supercapacitor hybrid system. The model framework of the lithium-ion battery and supercapacitor hybrid system is developed based on the equivalent circuit model, and the model parameters are identified by regression method. Explicit analyses of the power capability and maximum charge and discharge energy prediction with multiple constraints are elaborated. Subsequently, the extended Kalman filter is employed for on-board power capability and maximum charge and discharge energy prediction to overcome estimation error caused by system disturbance and sensor noise. The charge and discharge power capability, and the maximum charge and discharge energy are quantitatively assessed under both the dynamic stress test and the urban dynamometer driving schedule. The maximum charge and discharge energy prediction of the lithium-ion battery and supercapacitor hybrid system with different time scales are explored and discussed.

  10. Application of extended statistical combination of uncertainties methodology for digital nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    In, Wang Ki; Uh, Keun Sun; Chul, Kim Heui [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-02-01

    A technically more direct statistical combinations of uncertainties methodology, extended SCU (XSCU), was applied to statistically combine the uncertainties associated with the DNBR alarm setpoint and the DNBR trip setpoint of digital nuclear power plants. The modified SCU (MSCU) methodology is currently used as the USNRC approved design methodology to perform the same function. In this report, the MSCU and XSCU methodologies were compared in terms of the total uncertainties and the net margins to the DNBR alarm and trip setpoints. The MSCU methodology resulted in the small total penalties due to a significantly negative bias which are quite large. However the XSCU methodology gave the virtually unbiased total uncertainties. The net margins to the DNBR alarm and trip setpoints by the MSCU methodology agree with those by the XSCU methodology within statistical variations. (Author) 12 refs., 17 figs., 5 tabs.

  11. Extending applicability of bimetric theory: chameleon bigravity

    Science.gov (United States)

    De Felice, Antonio; Mukohyama, Shinji; Uzan, Jean-Philippe

    2018-02-01

    This article extends bimetric formulations of massive gravity to make the mass of the graviton to depend on its environment. This minimal extension offers a novel way to reconcile massive gravity with local tests of general relativity without invoking the Vainshtein mechanism. On cosmological scales, it is argued that the model is stable and that it circumvents the Higuchi bound, hence relaxing the constraints on the parameter space. Moreover, with this extension the strong coupling scale is also environmentally dependent in such a way that it is kept sufficiently higher than the expansion rate all the way up to the very early universe, while the present graviton mass is low enough to be phenomenologically interesting. In this sense the extended bigravity theory serves as a partial UV completion of the standard bigravity theory. This extension is very generic and robust and a simple specific example is described.

  12. Estimation of radon exhalation rate, natural radioactivity and radiation doses in fly ash samples from NTPC Dadri, (UP) India

    International Nuclear Information System (INIS)

    Gupta, Mamta; Verma, K.D.; Mahur, A.K.; Rajendra Prasad; Sonkawade, R.G.

    2010-01-01

    Fly ash produced by coal-burning in thermal power station has become a subject of world wide interest in recent years, because of its diverse uses in building materials such as bricks, sheets, cement and land filling etc. The knowledge of radio nuclides in fly ash plays an important role in health physics. Natural radioactivity and radon exhalation rate in fly ash samples collected from NTPC (National Thermal Power Corporation) Dadri, (UP.) India, have been studied. A high resolution gamma ray spectroscopic system has been used for the measurement of natural radioactivity. The activity concentration of natural radionuclides radium ( 226 Ra), thorium ( 232 Th) and potassium ( 40 K) were measured and radiological parameters were calculated. Radium concentration was found to vary from (81.01 ± 3.25) to (177.33 ±10.00) Bq kg -1 . Activity concentration of thorium was found to vary from (111.57 ± 3.21) to (178.50 ± 3.96) Bq kg -1 . Potassium activity was not significant in some samples, whereas, some other samples have shown potassium activity vary from (365.98 ± 4.85) to (495.95 ± 6.23) Bq kg -1 . Radon exhalation rates in these samples were also calculated by 'Sealed Can technique' using LR-115 type II detectors and found to vary from (80 ± 9) to (243 ± 16) mBqm -2 h -1 with an average value (155 ± 13) mBqm -2 h -1 . This study also presents the results of estimation of effective dose equivalent from exhalation rate, radium equivalent, absorbed gamma dose rates, external annual effective dose rate and values of external hazard index for the fly ash samples. (author)

  13. Energy, electricity and nuclear power estimates for the period up to 2020. Jul 1998 ed.

    International Nuclear Information System (INIS)

    1998-01-01

    Reference Data Series No. 1 is an annual publication - currently in its eighteenth edition - containing estimates of energy, electricity and nuclear power trends up to the year 2020. The time horizon covered in the previous editions was up to 2015. (author)

  14. Extending supplementary feeding for children younger than 5 years with moderate acute malnutrition leads to lower relapse rates

    Science.gov (United States)

    Children with moderate acute malnutrition (MAM) have a high rate of relapse and death in the year following recovery. In this pilot study, we evaluate the long-term benefits of an extended course of nutritional therapy for children with MAM. Rural Malawian children 6 to 59 months old with MAM, defin...

  15. Discrete rate and variable power adaptation for underlay cognitive networks

    KAUST Repository

    Abdallah, Mohamed M.; Salem, Ahmed H.; Alouini, Mohamed-Slim; Qaraqe, Khalid A.

    2010-01-01

    We consider the problem of maximizing the average spectral efficiency of a secondary link in underlay cognitive networks. In particular, we consider the network setting whereby the secondary transmitter employs discrete rate and variable power

  16. Rotating UPS installations and dynamic energy storage. Comparison of static and rotating UPS and comparison of dynamic energy storage using batteries - Final Report; Rotierende USV-Anlagen und dynamische Energiespeicherung. Vergleich der statischen mit rotierenden USV-Anlagen und Vergleich der dynamischen Energiespeicherung mit Batterieanlagen - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Mauchle, P.; Schnyder, G.

    2010-01-15

    As an alternative to the static UPS-Systems (uninterruptible power supply systems), rotating UPS-Systems can be applied. The application and the realisation of rotating UPS-Systems are different to the one of static UPS-Systems. Furthermore at the rotating UPS-Systems is to distinguish, if the UPS-System is realised as a diesel dynamic UPS-System, with an activity up from 400 kVA, or if the dynamic part is limited to the energy storage, with an activity up from 60 kVA. The diesel dynamic UPS-Systems are composed of a synchronous machine, an asynchronous machine with a flywheel, respectively a kinetic module and the diesel engine. The connection to the critical user at the low voltage network occurs using an inductor and the accordant switchgears. The application of a diesel dynamic UPS-System is optimal when it can be connected with an emergency power supply. With the realisation of dynamic energy storages, battery systems can be avoided respectively can be reduced or the lifetime of batteries can be extended. It is only possible to avoid the batteries if the requested autonomous time of the UPS-System is shorter than two minutes. Is an autonomous time longer than 2 minutes necessary, battery systems have to be realised for the energy storage. Thereby dynamic energy storage in parallel to the battery system is useful, because the dynamic energy storage will compensate temporary voltage drops or short power failures. In this way the number of charge and discharge cycles of the battery system will be reduced and therefore the lifetime of the battery will be extended. The use of a dynamic or static UPS system is dependent on the requirements of the powered load. Taking into account various criteria it can be found for each specific application the optimal type of UPS system. (authors)

  17. Concept, Design, and Prototyping of XSAS: A High Power Extendable Solar Array for CubeSat Applications

    Science.gov (United States)

    Senatore, Patrick; Klesh, Andrew; Zurbuchen, Thomas H.; McKague, Darren; Cutler, James

    2010-01-01

    CubeSats have proven themselves as a reliable and cost-effective method to perform experiments in space, but they are highly constrained by their specifications and size. One such constraint is the average continuous power, about 5 W, which is available to the typical CubeSat. To improve this constraint, we have developed the eXtendable Solar Array System (XSAS), a deployable solar array prototype in a CubeSat package, which can provide an average 23 W of continuous power. The prototype served as a technology demonstrator for the high risk mechanisms needed to release, deploy, and control the solar array. Aside from this drastic power increase, it is in the integration of each mechanism, their application within the small CubeSat form-factor, and the inherent passive control benefit of the deployed geometry that make XSAS a novel design. In this paper, we discuss the requirements and design process for the XSAS system and mechanical prototype, and provide qualitative and quantitative results from numerical simulations and prototype tests. We also discuss future work, including an upcoming NASA zero-gravity flight campaign, to further improve on XSAS and prepare it for future launch opportunities.

  18. Validation of the thermal balance of Laguna Verde turbine under conditions of extended power increase; Validacion del balance termico de turbina de Laguna Verde en condiciones de aumento de potencia extendido

    Energy Technology Data Exchange (ETDEWEB)

    Castaneda G, M. A.; Cruz B, H. J.; Mercado V, J. J.; Cardenas J, J. B.; Garcia de la C, F. M., E-mail: miguel.castaneda01@cfe.gob.mx [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Carretera Cardel-Nautla Km 42.5, Alto Lucero, Veracruz (Mexico)

    2012-10-15

    The present work is a continuation of the task: Modeling of the vapor cycle of Laguna Verde with the PEPSE code to conditions of thermal power licensed at present (2027 MWt) in which the modeling of the vapor cycle of the nuclear power plant of Laguna Verde was realized with PEPSE code (Performance Evaluation of Power System Efficiencies). Once reached the conditions of nominal operation of extended power increase, operating both units to 2371 MWt; after the tests phase of starting-up and operation is necessary to carry out a verification of the proposed design of the vapor cycle for the new operation conditions. All this, having in consideration that the vapor cycle designer only knows the detail of the prospective performance of the main turbine, for all the other components (for example pumps, heat inter changers, valves, reactor, humidity separators and re-heaters, condensers, etc.) makes generic suppositions based on engineering judgment. This way carries out the calculations of thermal balance to determine the guaranteed gross power. The purpose of the present work is to comment the detail of the validation carried out of the specific thermal balance (thermal kit) of the nuclear power plant, making use of the design characteristics of the different components that conform the vapor cycle. (Author)

  19. Complete Loss and Thermal Model of Power Semiconductors Including Device Rating Information

    DEFF Research Database (Denmark)

    Ma, Ke; Bahman, Amir Sajjad; Beczkowski, Szymon

    2015-01-01

    Thermal loading of power devices are closely related to the reliability performance of the whole converter system. The electrical loading and device rating are both important factors that determine the loss and thermal behaviors of power semiconductor devices. In the existing loss and thermal...

  20. Power and transmission rate orders and related documents. Office of Power Marketing Coordination, data compiled January 1, 1980-December 31, 1981

    Energy Technology Data Exchange (ETDEWEB)

    None

    1982-08-01

    This publication contains the power and transmission rate orders and related documents issued by the Department of Energy. It covers calendar years 1980 and 1981. The first publication, DOE/CE-007 covering the period from March through December 1979, was published July 1981. This publication is a compilation of all rate orders issued by the Assistant Secretary for Resource Applications and the Assistant Secretary for Conservation and Renewable Energy during calendar years 1980 and 1981 under Delegation Order No. 0204-33. It also includes all final approvals, remands, and disapprovals by the FERC, and a petition to the FERC for reconsideration by a Power Marketing Administration during 1980 and 1981. Also included are two delegation orders along with an amendment and a supplement to one delegation order, a departmental order on financial reporting, and Power and Transmission Rate Adjustment Procedures relating to federal power marketing.

  1. Joint Power Allocation and Beamforming in Amplify-and-Forward Relay Networks under Per-Node Power Constraint

    Directory of Open Access Journals (Sweden)

    Farzin Azami

    2017-01-01

    Full Text Available Two-way relay networks (TWRN have been intensively investigated over the past decade due to their ability to enhance the performance assessment of networks in terms of cellular coverage and spectral efficiency. Yet, power control in such systems is a nontrivial issue, particularly in multirelay networks where relays are deployed to ensure a required Quality of Service (QoS. In this paper, we envision to address this critical issue by minimizing the sum-power with respect to per-node power consumption and acceptable users’ rates. To tackle this, we employ a variable transformation to turn the fractional quadratically constrained quadratic problem (QCQP into semidefinite programming (SDP. This algorithm is also extended to a distributed format. Simulation results of deploying 10 relay stations reveal that the total power consumption will decrease to approximately 8 dBW for 6 bps/Hz sum-rate.

  2. Extending Wireless Rechargeable Sensor Network Life without Full Knowledge.

    Science.gov (United States)

    Najeeb, Najeeb W; Detweiler, Carrick

    2017-07-17

    When extending the life of Wireless Rechargeable Sensor Networks (WRSN), one challenge is charging networks as they grow larger. Overcoming this limitation will render a WRSN more practical and highly adaptable to growth in the real world. Most charging algorithms require a priori full knowledge of sensor nodes' power levels in order to determine the nodes that require charging. In this work, we present a probabilistic algorithm that extends the life of scalable WRSN without a priori power knowledge and without full network exploration. We develop a probability bound on the power level of the sensor nodes and utilize this bound to make decisions while exploring a WRSN. We verify the algorithm by simulating a wireless power transfer unmanned aerial vehicle, and charging a WRSN to extend its life. Our results show that, without knowledge, our proposed algorithm extends the life of a WRSN on average 90% of what an optimal full knowledge algorithm can achieve. This means that the charging robot does not need to explore the whole network, which enables the scaling of WRSN. We analyze the impact of network parameters on our algorithm and show that it is insensitive to a large range of parameter values.

  3. The Multidisk Diode-Pumped High Power Yb:YAG Laser Amplifier of High-Intensity Laser System with 1 kHz Repetition Rate

    Science.gov (United States)

    Kuptsov, G. V.; Petrov, V. V.; Petrov, V. A.; Laptev, A. V.; Kirpichnikov, A. V.; Pestryakov, E. V.

    2018-04-01

    The source of instabilities in the multidisk diode-pumped high power Yb:YAG laser amplifier with cryogenic closed-loop cooling in the laser amplification channel of the high-intensity laser system with 1 kHz repetition rate was determined. Dissected copper mounts were designed and used to suppress instabilities and to achieve repeatability of the system. The equilibrium temperature dependency of the active elements on average power was measured. The seed laser for the multidisk amplifier was numerically simulated and designed to allow one to increase pulses output energy after the amplifier up to 500 mJ.

  4. 78 FR 26771 - Mesa Wind Power Corporation; Supplemental Notice That Initial Market-Based Rate Filing Includes...

    Science.gov (United States)

    2013-05-08

    ... Wind Power Corporation's application for market-based rate authority, with an accompanying rate... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. ER13-1346-000] Mesa Wind Power Corporation; Supplemental Notice That Initial Market-Based Rate Filing Includes Request for...

  5. Achievable rate of spectrum sharing cognitive radio systems over fading channels at low-power regime

    KAUST Repository

    Sboui, Lokman; Rezki, Zouheir; Alouini, Mohamed-Slim

    2014-01-01

    the previously achieved rate at the low-power regime. Interestingly, we show that the low-power regime analysis provides a specific insight into the maximum achievable rate behavior of CR that has not been reported by previous studies.

  6. Survey of the power ramp performance testing of KWU'S PWR UO 2, fuel

    Science.gov (United States)

    Ga¨rtner, M.; Fischer, G.

    1987-06-01

    To determine the power ramp performance of KWU's PWR UO 2 fuel, 134 fuel rodlets with burnups of up to 46 GWd/ t (U) and several fuel assemblies with 19 to 30 GWd/t (U) burnup were ramped in power in the research reactors HFR Petten/The Netherlands and R2 Studsvik/Sweden and in the power plants KWO and KWB-A/Germany, respectively. The power ramp tests demonstrate decreasing resistance of the PWR fuel rods to PCI (pellet-to-clad interaction) up to fuel burnups of 35 GWd/t (U) and a reversal effect at higher burnups. The fuel rods can be operated free of defects at fast power transients to linear heat generation rates of up to 400 W/cm, at least.Power levels of up to 490 W/cm can be reached without defects by reducing the ramp rate. After reshuffling according to an out-in scheme, 1-cycle fuel assemblies may return to rod powers of up to 480 W/cm with a power increase rate of up to 10 W/(cm min) without fuel rod damage. Set points basing on these test results and incorporated into the power distribution control and power density limitation system of KWU's advanced power plants guarantee safe plant operation under normal and load follow operating conditions.

  7. A high rate gamma spectroscopy system for activation analysis of short lived isomeric transitions

    Energy Technology Data Exchange (ETDEWEB)

    Westphal, G P [Atominstitut, Vienna (Austria)

    1976-07-01

    A high rate spectroscopy system specially suited for measurement of short-lived isomeric transitions is described, which, as part of a fast activation analysis facility at the TRIGA Mark II reactor, provides for automatic recording and immediate evaluation of gamma spectra taken from nuclides activated at stationary or pulsed reactor power. The system consists of a commercial DC-coupled Ge(Li)-detector of 70 cm{sup 3} modified for recycling operation for input rates in excess of 500,000 c/s Co-60, a time variant trapezoidal shaping section and a fast constant dead-time ADC coupled to a programmed multi-channel analyzer. Novel circuits for efficient pile-up rejection and time variant base line restoration extend the concept of gated integration up to count rates of more than 300,000 c/s Co-60. Time-sequenced recording of spectra is performed by a mini computer operated as a front-end processor of a larger laboratory computer, where final data processing takes place. New concepts for very simple and cost-effective implementation of multi-channel analyzers by means of general purpose small computers are described. (author)

  8. Nuclear power: status and outlook

    International Nuclear Information System (INIS)

    Rogner, H.H.; Langlois, L.M.; McDonald, A.

    2001-01-01

    Nuclear power plants worldwide make important contributions to energy production. A total of 439 plants are in operation; with nearly 10 000 years of operating history, they reliably provide some 16 percent of the world's electricity production. The growth rates of nuclear power expansion in the seventies and eighties are no longer achievable now. Growing operating experience and further optimization of plant operation have caused the electricity generation in existing plants to grow overproportionally, corresponding to a calculated equivalent of 28 000 MW of capacity increment in the nineties. The short-term perspectives of nuclear power generation until 2020 as outlined by the International Energy Agency (IEA) indicate a slight decrease of electricity production with a variety of different regional developments. Over the same period of time, there will mainly be further improvements in reliable operation, resulting in higher availability and added safety, as well as measures extending plant life. Studies going beyond the time frame of the IEA Study forecast a major increase in nuclear generating capacity for the period after 2020 up to 2050. The foreseeable long-term developments on the world energy markets, with their limited fossil energy resources, are seen as a reason why nuclear power and renewable energies jointly will be important components in meeting energy requirements and, simultaneously, fulfilling the needs of climate protection. Specific problems of nuclear power, which can be solved, are seen to be the development of innovative plants, a stable cost situation, and the reduction of economic risks because of the long periods of payback of the capital invested. (orig.) [de

  9. Under Voltage Lock-Out Design Rules for Proper Start-Up of Energy Autonomous Systems Powered by Supercapacitors

    Science.gov (United States)

    Boitier, V.; Durand Estèbe, P.; Monthéard, R.; Bafleur, M.; Dilhac, J. M.

    2013-12-01

    This paper deals with the issue of the initial start-up of an autonomous and battery-free system powered by an energy harvester associated with a storage subsystem based on supercapacitors initially discharged. A review of different low power Under Voltage Lock-Out (UVLO) solutions used to delay the load start-up and to avoid a useless discharge of supercapacitors is presented and discussed.

  10. Model for the techno-economic analysis of common work of wind power and CCGT power plant to offer constant level of power in the electricity market

    Directory of Open Access Journals (Sweden)

    Tomsic Z.

    2017-01-01

    For calculation purposes, the following parameters are necessary to know in order to be able to economically evaluate changes in the start-up process: ramp up and down rate, time of start time reduction, fuel mass flow during start, electricity production during start, variable cost of start-up process, cost and charges for life time consumption for each start and start type, remuneration during start up time regarding expected or unexpected starts, the cost and revenues for balancing energy (important when participating in electricity market, and the cost or revenues for CO2-certificates. Main motivation for this analysis is to investigate possibilities to participate on power exchanges by offering continues guarantied power from wind plants by backing-up them with CCGT power plant.

  11. 77 FR 62510 - Niagara Wind Power, LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes...

    Science.gov (United States)

    2012-10-15

    ... Wind Power, LLC's application for market-based rate authority, with an accompanying rate schedule... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. ER13-17-000] Niagara Wind Power, LLC; Supplemental Notice That Initial Market- Based Rate Filing Includes Request for Blanket...

  12. The effects of static friction and backlash on extended physiological proprioception control of a powered prosthesis.

    Science.gov (United States)

    Farrell, Todd R; Weir, Richard F; Heckathorne, Craig W; Childress, Dudley S

    2005-01-01

    In general, externally powered prostheses do not provide proprioceptive feedback and thus require the user to rely on cognitively expensive visual feedback to effectively control the prosthesis. Applying the concept of extended physiological proprioception (EPP) to externally powered prostheses provides direct feedback to the user's proprioceptive system regarding the position, velocity, and forces applied to the prosthesis. However, electric elbows with EPP controllers developed at the Northwestern University Prosthetics Research Laboratory have exhibited unexplained "jerky" behavior in both clinical fittings and bench-top operation. In addition, the development of limit cycles, a specific type of constant-amplitude oscillation, had been observed in bench-top use of these elbows. Backlash and static friction within the EPP system were found to be primarily responsible for the development of limit cycles. Reducing static friction and backlash improved the system's performance. These results suggest that to most effectively implement EPP, prosthesis manufacturers should design prosthetic components that minimize static friction and backlash.

  13. Development of an Upper Limb Power Assist System Using Pneumatic Actuators for Farming Lift-up Motion

    Science.gov (United States)

    Yagi, Eiichi; Harada, Daisuke; Kobayashi, Masaaki

    A power assist system has lately attracted considerable attention to lifting-up an object without low back pain. We have been developing power assist systems with pneumatic actuators for the elbow and shoulder to farming support of lifting-up a bag of rice weighing 30kg. This paper describes the mechanism and control method of this power assist system. The pneumatic rotary actuator supports shoulder motion, and the air cylinder supports elbow motion. In this control method, the surface electromyogram(EMG) signals are used as input information of the controller. The joint support torques of human are calculated based on the antigravity term of necessary joint torques, which are estimated on the dynamics of a human approximated link model. The experimental results show the effectiveness of the proposed mechanism and control method of the power assist system.

  14. Overview Of Planning Direction Of Nuclear Power Development In Vietnam In The Period Up To 2030

    International Nuclear Information System (INIS)

    Ta Van Huong; Tran Hong Nguyen

    2011-01-01

    Research for peaceful application of nuclear energy, in general, and in particular, for construction of nuclear power plants (NPP) in Vietnam is urgent for social-economic development and for meeting the increasing national electrical demand in future. The expected plan for developing NPPs in Vietnam is defined in the Planning Direction of Nuclear Power Development in Vietnam in the period up to 2030. In according to which, NPPs have been planned in selected sites by the period depends on the detailed conditions of each site, as well as on specification of the national electrical grid. The present report reviews the highlights of this Planning Direction of Nuclear Power Development in Vietnam in the period up to 2030. (author)

  15. Transmission Characteristics of an OFDM signal for Power Line Communication System with High Bit Rate

    Science.gov (United States)

    Mori, Akira; Watanabe, Yosuke; Tokuda, Masamitsu; Kawamoto, Koji

    In this paper, we measured what influence the sinusoidal transmission characteristics of the electric power line with various forms gave to the transmission characteristic of OFDM (Orthogonal Frequency Division Multiplexing) signal through PLC (power line communication system) modem. We classified the electric power line transmission line with various forms in a real environment into two basic elements, which are an outlet type branch and a switch type branch. Next, PHY rate (Physical rate) is measured for each basic element connected with the PLC modem. At this time, the transmission characteristics of the electric power line are simulated from measured data. OFDM sending and receiving systems are composed on the computer, and the PHY rate is simulated. By comparing with measured and calculated values, it is revealed that PHY rate of PLC modem is most affected in the case of the power line transmission characteristics having broad band and high level attenuation and group delay variation, and is not affected in the case of that having narrow band attenuation and group delay variation.

  16. Lower foraging efficiency of offspring constrains use of optimal habitat in birds with extended parental care

    NARCIS (Netherlands)

    Nolet, B.A.; Gyimesi, A.; van Lith, B.

    2014-01-01

    Keywords: food intake rate; giving-up density; habitat switch; parental costs; social dominance After reproducing successfully, birds with extended parental care form family groups. Despite being the dominant social unit, such family groups have been reported to switch to alternative habitat earlier

  17. Extended reactivity trace curves for nuclear power control with no power shooting

    Energy Technology Data Exchange (ETDEWEB)

    Ratemi, W M; Elbuni, M S [Faculty of engineering, Al Fateh universty Tripoli (Libyan Arab Jamahiriya)

    1995-10-01

    This paper introduces a new concept of reactivity trace curve (RTC) for nuclear power control with no power shooting. The concept is based on recent work of bernard et al. on the dynamic period of nuclear reactors. RTC-method is simulated for both a static effective decay constant corresponding to a one-group delayed neutrons model, and a dynamic effective decay constant corresponding to a six-group delayed neutrons model. A fitting to the RTC of a six-group reactor model resulted in a closed from formula for the RTC that couples the effect of both static and dynamic decay constants. Hence, introducing two `fingerprints` for the reactor in concern to identify a closed from RTC formula capable of controlling the reactor power. Integration of the RTC with control rod integral curves results in the {rho}-z-t diagram. This diagram relates the amount of recommended reactivity (RTC), the position of control rod, and the time required for power control. 8 figs.

  18. Extended reactivity trace curves for nuclear power control with no power shooting

    International Nuclear Information System (INIS)

    Ratemi, W. M.; Elbuni, M. S.

    1995-01-01

    This paper introduces a new concept of reactivity trace curve (RTC) for nuclear power control with no power shooting. The concept is based on recent work of bernard et al. on the dynamic period of nuclear reactors. RTC-method is simulated for both a static effective decay constant corresponding to a one-group delayed neutrons model, and a dynamic effective decay constant corresponding to a six-group delayed neutrons model. A fitting to the RTC of a six-group reactor model resulted in a closed from formula for the RTC that couples the effect of both static and dynamic decay constants. Hence, introducing two 'fingerprints' for the reactor in concern to identify a closed from RTC formula capable of controlling the reactor power. Integration of the RTC with control rod integral curves results in the ρ-z-t diagram. This diagram relates the amount of recommended reactivity (RTC), the position of control rod, and the time required for power control. 8 figs

  19. Scale-up of mixer-settler for uranium extraction

    International Nuclear Information System (INIS)

    Santana, A.O. de.

    1990-05-01

    The aim of this work was to obtain scale-up relations for a box type mixer-settler used in uranium extraction process for chloridric leaches. Three box type units with different sizes and with the same geometry were used for scale-up of the mixer. The correlation between extraction rate and specific power input, D/T ratio (stirrer diameter/mixer length) and residence time were experimentally obtained. The results showed that the extraction increases with power input for a constant value of D/T equal to 1/3, remaining however independent from mixer sizes for a specific value of power input. This behavior was observed for power input values ranging from 100 to 750 w/m 9 . (author). 23 refs, 22 figs, 23 tabs

  20. Energy, electricity and nuclear power estimates for the period up to 2030. July 2003 ed

    International Nuclear Information System (INIS)

    2003-01-01

    Reference Data Series No. 1 is an annual publication - currently in its twenty-second edition - containing estimates of energy, electricity and nuclear power trends up to the year 2020. Nuclear data presented in Table 1 are based on actual statistical data collected by the IAEA's Power Reactor Information System (PRIS). Energy and electricity data for 2001, however, are estimated, since the latest available information from the Department of Economic and Social Affairs of the United Nations is for 1999. Population data originate from the 'World Population Prospects' (2001 Revision), published by the Population Division of the UN Department of Economic and Social Affairs, and the 2001 values are estimates. The future growth of energy, electricity and nuclear power up to the year 2020 is presented as low and high estimates in order to encompass the uncertainties associated with the future. These estimates should be viewed as very general growth trends whose validity must constantly be subjected to critical review. The nuclear generating capacity estimates presented in Table are derived from a country by country bottom-up approach. They are established by a group of experts participating each year in the IAEA's consultancy on Nuclear Capacity Projections and based upon a review of nuclear power projects and programmes in Member States. The total energy consumption has been calculated by summing the primary energy consumption and the net secondary energy import

  1. H-mode access during plasma current ramp-up in TCV

    International Nuclear Information System (INIS)

    Martin, Y.; Behn, R.; Furno, I.; Labit, B.; Reimerdes, H.

    2014-01-01

    A recent TCV experiment has investigated the dependence of the L–H transition threshold power on the plasma current ramp-rate and the X-point height above the divertor target, which both have previously been seen to affect the transition behaviour. Systematic scans in ohmically heated plasmas do not show any dependence on the plasma current ramp-up rate. In contrast, the threshold power is found to increase by a factor of two while the X-point is moved from about 10 cm up to 35 cm above the vessel floor. However, further increase, up to 60 cm, does not lead to any further increase of the required power. The Fundamenski et al model is tested against the measurements. Estimates of the Wagner number (Wa) at L–H transitions are generally close to unity, in accordance with the model. In contrast, estimates of Wa before the L–H transition, i.e. in L-mode, do not show the expected evolution towards unity. (paper)

  2. Lithium Ion Battery Chemistries from Renewable Energy Storage to Automotive and Back-up Power Applications

    DEFF Research Database (Denmark)

    Stan, Ana-Irina; Swierczynski, Maciej Jozef; Stroe, Daniel Ioan

    2014-01-01

    Lithium ion (Li-ion) batteries have been extensively used in consumer electronics because of their characteristics, such as high efficiency, long life, and high gravimetric and volumetric energy. In addition, Li-ion batteries are becoming the most attractive candidate as electrochemical storage...... systems for stationary applications, as well as power source for sustainable automotive and back-up power supply applications. This paper gives an overview of the Li-ion battery chemistries that are available at present in the market, and describes the three out of four main applications (except...... the consumers’ applications), grid support, automotive, and back-up power, for which the Li-ion batteries are suitable. Each of these applications has its own specifications and thus, the chemistry of the Li-ion battery should be chosen to fulfil the requirements of the corresponding application. Consequently...

  3. 78 FR 56691 - Sapphire Power Marketing LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes...

    Science.gov (United States)

    2013-09-13

    ... Power Marketing LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes Request for... Sapphire Power Marketing LLC's application for market-based rate authority, with an accompanying rate... submission of protests and interventions in lieu of paper, using the FERC Online links at http://www.ferc.gov...

  4. FABGEN, a transient power-generation and isotope birth rate calculator

    International Nuclear Information System (INIS)

    Roland, H.C.

    1975-04-01

    A description is given of the FABGEN program, a fast-running program for calculating fuel element power-generation rates and selected fission product birth rates in a known neutron flux as functions of time. A first forward difference calculation is used, and the time step is one day. Provisions are made for including various fuel element lengths, variation of thermal flux with time, and use of different fertile isotopes. Five different fission products may be specified for birth-rate calculations. A daily summary may be output, or totals by days may be accumulated for final output. (U.S.)

  5. Numerical simulation of the heating and start-up of PWR nuclear power station

    International Nuclear Information System (INIS)

    Faraco-Medeiros, M.A.; Leite, C.A.T.; Ramalho, F.P.

    1992-01-01

    The start-up of a PWR nuclear power plant must be done within safety criteria and requires a simulation. The design of some equipment, cost and time can be optimized. A computer simulator, which allows control of all the equipment and variables into the operation, has been developed and is presented in this paper. The KWU procedure and an alternative for Angra II were simulated. The results are showed up. 09 refs, 03 figs. (B.C.A.)

  6. Mortality over an extended follow-up period in coal workers exposed to respirable dust and quartz

    Energy Technology Data Exchange (ETDEWEB)

    Miller, B.G.; MacCalman, L.; Hutchison, P.A.

    2009-10-15

    In the 1950s the Pneumoconiosis Field Research (PFR) programme was set up to study the health of British coalworkers. Studies included regular health surveys, an intensive characterisation of workers' individual exposures, and entry to a cohort followed up to the present for cause-specific mortality. This study reports on analyses of cause-specific mortality in a cohort of almost 18,000 men from 10 collieries. External analyses used standardised mortality ratios, comparing observed mortality with reference rates from the regions in which the pits were situated. Causes investigated include lung and stomach cancers, nonmalignant respiratory diseases, and cardiovascular endpoints. Internal analyses used Cox regression models with time-dependent exposures adjusting for the confounding effects of age, smoking, cohort entry date and regional differences in population mortality rates. Several causes showed evidence of a healthy worker effect early in the follow-up, with a deficit in the SMR diminishing over time. For most of the causes there was a significant excess in the latter part of follow-up. Internal analyses found evidence of an association between increased risks of lung cancer and increased quartz exposure, particularly at a lag of 15 years. Risks of mortality from non-malignant respiratory disease, and specifically chronic obstructive pulmonary disease and pneumoconiosis, showed increases with increased exposure to respirable dust. 60 refs.

  7. The influence of modified water chemistries on metal oxide films, activity build-up and stress corrosion cracking of structural materials in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Maekelae, K.; Laitinen, T.; Bojinov, M. [VTT Manufacturing Technology, Espoo (Finland)

    1999-03-01

    The primary coolant oxidises the surfaces of construction materials in nuclear power plants. The properties of the oxide films influence significantly the extent of incorporation of actuated corrosion products into the primary circuit surfaces, which may cause additional occupational doses for the maintenance personnel. The physical and chemical properties of the oxide films play also an important role in different forms of corrosion observed in power plants. This report gives a short overview of the factors influencing activity build-up and corrosion phenomena in nuclear power plants. Furthermore, the most recent modifications in the water chemistry to decrease these risks are discussed. A special focus is put on zinc water chemistry, and a preliminary discussion on the mechanism via which zinc influences activity build-up is presented. Even though the exact mechanisms by which zinc acts are not yet known, it is assumed that Zn may block the diffusion paths within the oxide film. This reduces ion transport through the oxide films leading to a reduced rate of oxide growth. Simultaneously the number of available adsorption sites for {sup 60}Co is also reduced. The current models for stress corrosion cracking assume that the anodic and the respective cathodic reactions contributing to crack growth occur partly on or in the oxide films. The rates of these reactions may control the crack propagation rate and therefore, the properties of the oxide films play a crucial role in determining the susceptibility of the material to stress corrosion cracking. Finally, attention is paid also on the novel techniques which can be used to mitigate the susceptibility of construction materials to stress corrosion cracking. (orig.) 127 refs.

  8. The influence of modified water chemistries on metal oxide films, activity build-up and stress corrosion cracking of structural materials in nuclear power plants

    International Nuclear Information System (INIS)

    Maekelae, K.; Laitinen, T.; Bojinov, M.

    1999-03-01

    The primary coolant oxidises the surfaces of construction materials in nuclear power plants. The properties of the oxide films influence significantly the extent of incorporation of actuated corrosion products into the primary circuit surfaces, which may cause additional occupational doses for the maintenance personnel. The physical and chemical properties of the oxide films play also an important role in different forms of corrosion observed in power plants. This report gives a short overview of the factors influencing activity build-up and corrosion phenomena in nuclear power plants. Furthermore, the most recent modifications in the water chemistry to decrease these risks are discussed. A special focus is put on zinc water chemistry, and a preliminary discussion on the mechanism via which zinc influences activity build-up is presented. Even though the exact mechanisms by which zinc acts are not yet known, it is assumed that Zn may block the diffusion paths within the oxide film. This reduces ion transport through the oxide films leading to a reduced rate of oxide growth. Simultaneously the number of available adsorption sites for 60 Co is also reduced. The current models for stress corrosion cracking assume that the anodic and the respective cathodic reactions contributing to crack growth occur partly on or in the oxide films. The rates of these reactions may control the crack propagation rate and therefore, the properties of the oxide films play a crucial role in determining the susceptibility of the material to stress corrosion cracking. Finally, attention is paid also on the novel techniques which can be used to mitigate the susceptibility of construction materials to stress corrosion cracking. (orig.)

  9. The Influence Of Modified Water Chemistries On Metal Oxide Films, Activity Build-Up And Stress Corrosion Cracking Of Structural Materials In Nuclear Power Plants

    International Nuclear Information System (INIS)

    Maekelae, K.; Laitinen, T.; Bojinov, M.

    1998-07-01

    The primary coolant oxidises the surfaces of construction materials in nuclear power plants. The properties of the oxide films influence significantly the extent of incorporation of activated corrosion products into the primary circuit surfaces, which may cause additional occupational doses for the maintenance personnel. The physical and chemical properties of the oxide films play also an important role in different forms of corrosion observed in power plants. This report gives a short overview of the factors influencing activity build-up and corrosion phenomena in nuclear power plants. Furthermore, the most recent modifications in the water chemistry to decrease these risks are discussed. A special focus is put on zinc water chemistry, and a preliminary discussion on the mechanism via which zinc influences activity build-up is presented. Even though the exact mechanisms by which zinc acts are not yet known, it is assumed that Zn may block the diffusion paths within the oxide film. This reduces ion transport through the oxide films leading to a reduced rate of oxide growth. Simultaneously the number of available adsorption sites for 60 Co is also reduced. The current models for stress corrosion cracking assume that the anodic and the respective cathodic reactions contributing to crack growth occur partly on or in the oxide films. The rates of these reactions may control the crack propagation rate and therefore, the properties of the oxide films play a crucial role in determining the susceptibility of the material to stress corrosion cracking. Finally, attention is paid also on the novel techniques which can be used to mitigate the susceptibility of construction materials to stress corrosion cracking. (author)

  10. Updated mortality follow-up among French AREVA NC workers: 1977-2004

    International Nuclear Information System (INIS)

    Metz-Flamant, C.; Rogel, A.; Samson, E.; Laurier, D.; Tirmarche, M.; Caer, S.; Quesne, B.; Acker, A.

    2008-01-01

    Full text: Introduction: This study has been established in order to evaluate the mortality of nuclear workers employed at the French company specialized in nuclear fuel cycle (AREVA NC ex COGEMA) and exposed to low level of ionizing radiation. The follow-up of the cohort has been extended recently. We present here a new analysis of the mortality based on an extended follow-up of the cohort by 10 years. Methods: Administrative data, vital status and causes of death were reconstructed for each worker. Standardized Mortality ratios (SMR) were computed using national mortality rates as external reference adjusted for sex, age and calendar year. Trend tests were computed to assess the association between different causes of death and radiation exposure considering adjustment on socioeconomic status (SES). Results: 93% of the 9,285 workers were male workers. They were followed for an average of 22 years, with a total number of person-years of 206,603. The % of subjects lost to follow-up was less than 1%. 1,052 deaths occurred during the total follow-up period. 98% of the causes of death were identified. Mean age at end of follow-up was 56 years. As excepted, a strong deficit was observed for all causes of death (SMR=0.64; 90% confidence interval CI : 0.60-0.67) and all cancer mortality (SMR=0.77; 90% confidence interval CI : 0.71-0.83). No significant excess was found for any of the considered causes of death. The all-causes and all cancers SMRs increased significantly with cumulative dose, but after adjusting on SES, these positive trends were no longer statistically significant. Among the 30 causes of deaths studied, significant trends were observed for colon, liver cancer and for non-cancer respiratory diseases. Conclusion: AREVA NC workers exposed to ionizing radiation have a lower mortality than the French national population, partly due to the Healthy Worker Effect. It is important to adjust on SES in the dose-effect relationship analysis. Although follow-up has

  11. Life extension for German nuclear power plants

    International Nuclear Information System (INIS)

    Heller, W.

    2005-01-01

    The Federation of German Industries (BDI) commissioned a study of the ''Economic Effects of Alternative Lifetimes of Nuclear Power Plants in Germany.'' The expert organizations invited as authors were the Power Economy Institute of the University of Cologne (EWI) and Energy Environment Forecast Analysis GmbH (EEFA), Berlin. The reasons for commissioning the Study include the changed framework conditions (deregulation, CO 2 emission certificate trading, worldwide competition for resources), which have altered the energy supply situation in Europe. The findings of the Study were presented to the public by the BDI on October 26, 2005. The study deals with two scenarios of extended lifetimes for German nuclear power plants of 40 and 60 years as against the existing regulations with plant lifetimes limited to approx. 32 years. The longer service lives of plants are reflected in reduced electricity generation costs and thus may have a positive influence on electricity prices. Moreover, there would be additional growth of production together with additional jobs, all of which would add up to nearly 42,000 persons for all sectors of the economy as compared to the basic scenario. Also, CO 2 emissions could be curbed by up to 50 million tons of carbon dioxide. The Study offers ample and valid reasons in favor of extending the lifetimes of nuclear power plants. In the interest of general welfare, politics would be well advised to relax the restrictions on plant life in the course of this legislative term. (orig.)

  12. Long-term efficacy of ultrasound-guided low power microwave ablation for the treatment of primary papillary thyroid microcarcinoma: a 3-year follow-up study.

    Science.gov (United States)

    Teng, Dengke; Sui, Guoqing; Liu, Caimei; Wang, Yu; Xia, Yongxu; Wang, Hui

    2018-04-01

    To evaluate the safety and efficacy of ultrasound-guided low-power microwave ablation (MWA) for the treatment of papillary thyroid microcarcinoma (PTMC) with a 3-year follow-up. A total of 21 nodules diagnosed as PTMC from the 15 patients were performed with MWA at a power of 20 W. The images of the nodules were recorded by ultrasound before MWA and 1, 3, 6, 12 months after MWA, and every 6 months thereafter, respectively. The volumes of the nodules were compared before MWA and at each follow-up point after MWA. The volume reduction rate (VRR) of nodules was also calculated. The mean volume of the nodules was 134.3 ± 129.8 mm 3 initially (the range was 7.4-423.8 mm 3 ), which decreased significantly to 2.3 ± 10.5 mm 3 (the range was 0-48.1 mm 3 ) of the ablation area (P = 0.000) at the follow-up point of 36 months with a mean VRR as 98.78 ± 5.61% (the range was 74.28-100%). During the follow-up period (the range was 36-48 months), 20 of the 21 nodules were completely absorbed and no recurrent nodule was found. After a long-term follow-up of 3 years, the low power MWA showed a good safety and efficacy for the treatment of PTMC. In addition to surgery and active surveillance, MWA might be another alternative for patients with PTMC.

  13. Twenty years from the start-up of A-1, the first Czechoslovak nuclear power plant

    International Nuclear Information System (INIS)

    Komarek, A.

    1992-01-01

    On the occasion of the 20th anniversary of the start-up of A-1, the first Czechoslovak nuclear power plant, some less widely known data concerning the background of its development and construction, its importance for Czechoslovak engineering, and some conclusions for the future development of the Czechoslovak power industry are presented. (author) 3 figs

  14. PowerChoice Residential Customer Response to TOU Rates

    Energy Technology Data Exchange (ETDEWEB)

    Peters, Jane S.; Moezzi, Mithra; Lutzenhiser, Susan; Woods, James; Dethman, Linda; Kunkle, Rick

    2009-10-01

    Research Into Action, Inc. and the Sacramento Municipal Utility District (SMUD) worked together to conduct research on the behaviors and energy use patterns of SMUD residential customers who voluntarily signed on to a Time-of-Use rate pilot launched under the PowerChoice label. The project was designed to consider the how and why of residential customers ability and willingness to engage in demand reduction behaviors, and to link social and behavioral factors to observed changes in demand. The research drew on a combination of load interval data and three successive surveys of participating households. Two experimental treatments were applied to test the effects of increased information on households ability to respond to the Time-of-Use rates. Survey results indicated that participants understood the purpose of the Time-of-Use rate and undertook substantial appropriate actions to shift load and conserve. Statistical tests revealed minor initial price effects and more marked, but still modest, adjustments to seasonal rate changes. Tests of the two information interventions indicated that neither made much difference to consumption patterns. Despite the lackluster statistical evidence for load shifting, the analysis points to key issues for critical analysis and development of residential Time-of-Use rates, especially pertinent as California sets the stage for demand response in more California residences.

  15. Outlook for Global Nuclear Power: Energy, Electricity and Nuclear Power Estimates for the Period up to 2050

    International Nuclear Information System (INIS)

    Gritsevskyi, A.

    2016-01-01

    Nuclear power's global expansion is projected to continue in the coming decades - albeit at a slowing pace - amid challenges including low fossil fuel prices, a sluggish world economy and the legacy of Japan's Fukushima Daiichi accident. Each year, the IAEA publishes projections of the world's nuclear power generating capacity in Energy, Electricity and Nuclear Power Estimates for the Period up to 2050, now in its 35th edition.The latest projections point to slower growth in nuclear power, in keeping with the trend since the 2011 Fukushima Daiichi accident. The world's nuclear power generating capacity is projected to expand by 2.4 percent by 2030, according to the low projections, compared with 7.7 percent estimated in 2014. In the high case, generating capacity is estimated to grow by 68 percent by 2030, versus 88 percent forecast last year. Uncertainty related to energy policy, license renewals, shutdowns and future constructions accounts for the wide range.The estimates also factor in the likely future retirement of many of the world's 438 nuclear reactors currently in operation, more than half of which are over 30 years old. Despite the need to replace scores of retiring reactors, nuclear power is still set to maintain - and possibly increase - its role in the world's low-carbon energy mix. It's important to understand that these projections, while carefully derived, are not predictions.The estimates should be viewed as very general growth trends, whose validity must be constantly subjected to critical review.(author).

  16. Approximation for the Finite-Time Ruin Probability of a General Risk Model with Constant Interest Rate and Extended Negatively Dependent Heavy-Tailed Claims

    Directory of Open Access Journals (Sweden)

    Yang Yang

    2011-01-01

    Full Text Available We propose a general continuous-time risk model with a constant interest rate. In this model, claims arrive according to an arbitrary counting process, while their sizes have dominantly varying tails and fulfill an extended negative dependence structure. We obtain an asymptotic formula for the finite-time ruin probability, which extends a corresponding result of Wang (2008.

  17. Discrete rate and variable power adaptation for underlay cognitive networks

    KAUST Repository

    Abdallah, Mohamed M.

    2010-01-01

    We consider the problem of maximizing the average spectral efficiency of a secondary link in underlay cognitive networks. In particular, we consider the network setting whereby the secondary transmitter employs discrete rate and variable power adaptation under the constraints of maximum average transmit power and maximum average interference power allowed at the primary receiver due to the existence of an interference link between the secondary transmitter and the primary receiver. We first find the optimal discrete rates assuming a predetermined partitioning of the signal-to-noise ratio (SNR) of both the secondary and interference links. We then present an iterative algorithm for finding a suboptimal partitioning of the SNR of the interference link assuming a fixed partitioning of the SNR of secondary link selected for the case where no interference link exists. Our numerical results show that the average spectral efficiency attained by using the iterative algorithm is close to that achieved by the computationally extensive exhaustive search method for the case of Rayleigh fading channels. In addition, our simulations show that selecting the optimal partitioning of the SNR of the secondary link assuming no interference link exists still achieves the maximum average spectral efficiency for the case where the average interference constraint is considered. © 2010 IEEE.

  18. The Influence of International Parity on the Exchange Rate: Purchasing Power Parity and International Fisher Effect

    OpenAIRE

    Oana Mionel

    2012-01-01

    This article assesses the impact of the inflation and interest rates on the exchange rates. The analysis tests the relation between the inflation rate and the exchange rate by applying the Purchasing Power Parity Theory, while the relation between the interest rate and the inflation rate is tested by applying the International Fisher Effect Theory. In order to test the Purchasing Power Parity the study takes into account the period of time between 1990 – 2009, and the following countries – th...

  19. Estimation of component failure rates for PSA on nuclear power plants 1982-1997

    International Nuclear Information System (INIS)

    Kirimoto, Yukihiro; Matsuzaki, Akihiro; Sasaki, Atsushi

    2001-01-01

    Probabilistic safety assessment (PSA) on nuclear power plants has been studied for many years by the Japanese industry. The PSA methodology has been improved so that PSAs for all commercial LWRs were performed and used to examine for accident management.On the other hand, most data of component failure rates in these PSAs were acquired from U.S. databases. Nuclear Information Center (NIC) of Central Research Institute of Electric Power Industry (CRIEPI) serves utilities by providing safety- , and reliability-related information on operation and maintenance of the nuclear power plants, and by evaluating the plant performance and incident trends. So, NIC started a research study on estimating the major component failure rates at the request of the utilities in 1988. As a result, we estimated the hourly-failure rates of 47 component types and the demand-failure rates of 15 component types. The set of domestic component reliability data from 1982 to 1991 for 34 LWRs has been evaluated by a group of PSA experts in Japan at the Nuclear Safety Research Association (NSRA) in 1995 and 1996, and the evaluation report was issued in March 1997. This document describes the revised component failure rate calculated by our re-estimation on 49 Japanese LWRs from 1982 to 1997. (author)

  20. Extended likelihood inference in reliability

    International Nuclear Information System (INIS)

    Martz, H.F. Jr.; Beckman, R.J.; Waller, R.A.

    1978-10-01

    Extended likelihood methods of inference are developed in which subjective information in the form of a prior distribution is combined with sampling results by means of an extended likelihood function. The extended likelihood function is standardized for use in obtaining extended likelihood intervals. Extended likelihood intervals are derived for the mean of a normal distribution with known variance, the failure-rate of an exponential distribution, and the parameter of a binomial distribution. Extended second-order likelihood methods are developed and used to solve several prediction problems associated with the exponential and binomial distributions. In particular, such quantities as the next failure-time, the number of failures in a given time period, and the time required to observe a given number of failures are predicted for the exponential model with a gamma prior distribution on the failure-rate. In addition, six types of life testing experiments are considered. For the binomial model with a beta prior distribution on the probability of nonsurvival, methods are obtained for predicting the number of nonsurvivors in a given sample size and for predicting the required sample size for observing a specified number of nonsurvivors. Examples illustrate each of the methods developed. Finally, comparisons are made with Bayesian intervals in those cases where these are known to exist

  1. Sustained safety and efficacy of extended-shelf-life {sup 90}Y glass microspheres: long-term follow-up in a 134-patient cohort

    Energy Technology Data Exchange (ETDEWEB)

    Lewandowski, Robert J.; Minocha, Jeet; Memon, Khairuddin; Riaz, Ahsun; Gates, Vanessa L.; Ryu, Robert K.; Sato, Kent T.; Omary, Reed; Salem, Riad [Northwestern University, Department of Radiology, Chicago, IL (United States)

    2014-03-15

    To validate our initial pilot study and confirm sustained safety and tumor response of extended-shelf-life {sup 90}Y glass microspheres. We hypothesized that for the same planned tissue dose, the increase in number of glass microspheres (decayed to the second week of their allowable shelf-life) administered for the same absorbed dose would result in better tumor distribution of the microspheres without causing additional adverse events. Between June 2007 and January 2010, 134 patients underwent radioembolization with extended-shelf-life {sup 90}Y glass microspheres; data from 84 new patients were combined with data from our 50-patient pilot study cohort. Baseline and follow-up imaging and laboratory data were obtained 1 and 3 months after therapy and every 3 months thereafter. Clinical and biochemical toxicities were prospectively captured and categorized according to the Common Terminology Criteria. Response in the index lesion was assessed using WHO and EASL guidelines. The mean delivered radiation dose was 123 Gy to the target liver tissue. The mean increase in number of microspheres with this approach compared to standard {sup 90}Y glass microsphere dosimetry was 103 %, corresponding to an increase from 3.84 to 7.78 million microspheres. Clinical toxicities included fatigue (89 patients, 66 %), abdominal pain (49 patients, 36.6 %), and nausea/vomiting (25 patients, 18.7 %). Grade 3/4 bilirubin toxicity was seen in three patients (2 %). Two (1 %) of the initial 50-patient cohort showed gastroduodenal ulcers; gastroduodenal ulcers were not seen in any of the subsequent 84 patients. According to WHO and EASL guidelines, response rates were 48 % and 57 %, respectively, and 21 % demonstrated a complete EASL response. This study showed sustained safety and efficacy of extended-shelf-life {sup 90}Y glass microspheres in a larger, 134-patient cohort. The increase in number of microspheres administered theoretically resulted in better tumor distribution of the

  2. Proposal for implementation of alternative source term in the nuclear power plant of Laguna Verde; Propuesta de implementacion del termino fuente alternativo en la central nuclear Laguna Verde

    Energy Technology Data Exchange (ETDEWEB)

    Bazan L, A.; Lopez L, M.; Vargas A, A.; Cardenas J, J. B. [Comision Federal de Electricidad, Central Nucleoelectrica Laguna Verde, Km. 7.5 Carretera Veracruz-Medellin, Dos Bocas, Veracruz (Mexico)], e-mail: ariadna.bazan@cfe.gob.mx

    2009-10-15

    In 2010 the nuclear power plant of Laguna Verde will implement the extended power upbeat in both units of the plant. Agree with methodology of NEDC-33004P-A, (constant pressure power up rate), and the source term of core, for accidents evaluations, were increased in proportion to the ratio of power level. This means that for the case of a design basis accident of loss of coolant an increase of power of 15% originated an increase of 15% in dose to main control room. Using the method of NEDC-33004P-A to extended power upbeat conditions was determined that the dose value to main control room is very near to regulatory limit established by SRP 6.4. By the above and in order to recover the margin, the nuclear power plant of Laguna Verde will calculate an alternative source term following the criteria established in RG 1.183 (alternative radiological source term for evaluating DBA at nuclear power reactor). This approach also have a more realistic dose value using the criterion of 10-CFR-50.67, in addition is predicted to get the benefit of additional operational flexibilities. This paper present the proposal of implementing the alternative source term in Laguna Verde. (Author)

  3. Assessment of Coping Capability of KORI Unit 1 under Extended Loss AC Power and Loss of Ultimate Heat Sink Initiated by Beyond Design Natural Disaster

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Hyun; Ha, Sang Jun [KHNP CRI, Daejeon (Korea, Republic of); Han, Kee Soo [Nuclear Engineering Service and Solution (NESS) Co. Ltd., Deajeon (Korea, Republic of); Park, Chan Eok [KEPCO Engineering and Constructd., Deajeon (Korea, Republic of)

    2016-10-15

    In Korea, the government and industry performed comprehensive safety inspection on all domestic nuclear power plants against beyond design basis external events and fifty action items have been issued. In addition to post- Fukushima action items, the stress tests for all domestic nuclear power plants are on the way to enhance the safety of domestic nuclear power plants through finding the vulnerabilities in intentional stress conditions initiated by beyond design natural disaster. This paper presents assessment results of coping capability of KORI Unit 1 under the simultaneous Extended Loss of AC Power (ELAP) and Loss of Ultimate Heat Sink (LUHS) which is a representative plant condition initiated by beyond design natural disaster. The assessment of the coping capability of KORI Unit 1 has been performed under simultaneous the extended loss of AC power and loss of ultimate heat sink initiated by beyond design natural disaster. It is concluded that KORI Unit 1 has the capability, in the event of loss of safety functions by beyond design natural disaster, to sufficiently cool down the reactor core without fuel damage, to keep pressure boundaries of the reactor coolant system in transient condition and to control containment and temperature to maintain the integrity of the containment buildings.

  4. Assessment of Coping Capability of KORI Unit 1 under Extended Loss AC Power and Loss of Ultimate Heat Sink Initiated by Beyond Design Natural Disaster

    International Nuclear Information System (INIS)

    Kim, Chang Hyun; Ha, Sang Jun; Han, Kee Soo; Park, Chan Eok

    2016-01-01

    In Korea, the government and industry performed comprehensive safety inspection on all domestic nuclear power plants against beyond design basis external events and fifty action items have been issued. In addition to post- Fukushima action items, the stress tests for all domestic nuclear power plants are on the way to enhance the safety of domestic nuclear power plants through finding the vulnerabilities in intentional stress conditions initiated by beyond design natural disaster. This paper presents assessment results of coping capability of KORI Unit 1 under the simultaneous Extended Loss of AC Power (ELAP) and Loss of Ultimate Heat Sink (LUHS) which is a representative plant condition initiated by beyond design natural disaster. The assessment of the coping capability of KORI Unit 1 has been performed under simultaneous the extended loss of AC power and loss of ultimate heat sink initiated by beyond design natural disaster. It is concluded that KORI Unit 1 has the capability, in the event of loss of safety functions by beyond design natural disaster, to sufficiently cool down the reactor core without fuel damage, to keep pressure boundaries of the reactor coolant system in transient condition and to control containment and temperature to maintain the integrity of the containment buildings

  5. Load following operation of nuclear power plants for meeting power system requirements

    International Nuclear Information System (INIS)

    Isoda, Hachiro

    1987-01-01

    This paper describes a calculating program on the availability factors of nuclear, thermal and pumed storage hydro power stations and some calculated results for typical three load factors, 55 %, 60 % and 71 %, are provided when the share of the nuclea power station in the generation facilities is increased. The load following requirement of the nuclear power station is also provided. Load following requirement: If there is a 10 % pumped storage hydro power station, the nuclear power station enables to be operated with its rated output up to 30 % - 35 % of its share. Its daily load following operation for 40 % and 50 % nuclear power station needs every weekend and every day respectively. Availability factor: The availability factor of the nuclear power station manages to get 80 % (maximum availability factor of the nuclear power station in this study) up to 30 % share of it with 10 % pumpued storage hydro power station. When the nuclear power station shares 40 % and 50 %, its availability factor decreases down 1 % and 5 % respectively. (author)

  6. Start up and commercial operation of Laguna Verde nuclear power plant. Unit 1

    International Nuclear Information System (INIS)

    Torres Ramirez, J.F.

    1991-01-01

    Prior to start up of Laguna Verde nuclear power plant preoperational tests and start tests were performed and they are described in its more eminent aspects. In relation to commercial operation of nuclear station a series of indicator were set to which allow the measurement of performance in unit 1, in areas of plant efficiency and personal safety. Antecedents. Laguna Verde station is located in Alto Lucero municipality in Veracruz state, 70 kilometers north-northeast from port of Veracruz and a 290 kilometers east-northeast from Mexico city. The station consist of two units manufactured by General Electric, with a nuclear system of vapor supply also called boiling water (BWR/5), and with a system turbine-generator manufactured by Mitsubishi. Each unit has a nominal power of 1931 MWt and a level design power of 675 Mwe and a net power of 654 Electric Megawatts

  7. On the rate determining step in fission gas release from high burn-up water reactor fuel during power transients

    International Nuclear Information System (INIS)

    Walker, C.T.; Mogensen, M.

    1987-01-01

    The radial distribution of grain boundary gas in a PWR and a BWR fuel is reported. The measurements were made using a new approach involving X-ray fluorescence analysis and electron probe microanalysis. In both fuels the concentration of grain boundary gas was much higher than hitherto suspected. The gas was mainly contained in the bubble/pore structure. The factors that determined the fraction of gas released from the grains and the level of gas retention on the grain boundaries are identified and discussed. The variables involved are the local fuel stoichiometry, the amount of open porosity, the magnitude of the local compressive hydrostatic stress and the interaction of metallic precipitates with gas bubbles on the grain faces. It is concluded that under transient conditions the interlinkage of gas bubbles on the grain faces and the subsequent formation of grain edge tunnels is the rate determining step for gas release; at least when high burn-up fuel is involved. (orig.)

  8. Analysis of power ramp rate and minimum power controllability of the MMS model for a plant dynamics analysis of a Prototype SFR

    International Nuclear Information System (INIS)

    Kim, Eui Kwang; Kim, Dehee; Joo, Hyungkook; Lee, Taeho

    2014-01-01

    A full plant dynamic model was developed for a prototype SFR using the Modular Modeling System (MMS). It includes the modeling of various subsystems such as the neutronics, primary and intermediate sodium systems of the NSSS, steam and water systems of the BOP, BOP controls, and the supervisory plant controls. The NSSS model is subdivided into component models, such as a Core, IHXs, Pumps, SGs, and the rest of the NSSS loop model. The BOP model is subdivided into a steam subsystem, feedwater subsystem, and preheater subsystem. Plant transient tests were performed to study the operational considerations. It includes varying the power ramp rate and studying the controllability at minimum power. Plant transient tests were performed to study operational considerations by using the MMS model for a prototype SFR. It includes varying the power ramp rate, studying the controllability at the minimum power set point. At a power ramp rate of higher than 2%, the steam temperature has a large deviation from the target. As the power set point decreases, the PHTS hot leg temperature and steam temperature tend to have higher deviations. After further refinement of the MMS model, it can be useful for developing the plant operation logics of the prototype SFR

  9. Current status of power uprates and safety issues

    International Nuclear Information System (INIS)

    Park, J. S.; Song, J. H.; Lee, S. H.

    2002-01-01

    The power uprates is the process for increasing the available rated power of commercial nuclear power reactor, utilizing thermal and design margin already secured at the stage of design, or by reducing measurement uncertainty of thermal power. Power uprates can be classified in three categories: (1) measurement uncertainty recapture power uprates, (2) stretch power uprates, and (3) extended power uprates. In the United states, Calvert Cliffs Unit 1 increased 5.5 percent of the rated power of reactor power by means of stretch power uprates for the first time in 1997, and 81 more nuclear power plants are in operation with the licensed rated power increase as of June 2002. The applications of power uprate amendment of 16 nuclear power plants are scheduled to be submitted by the year 2006. With the commercial operation of nuclear power plant started in 1978, Korea now has a total thermal power marking at 40,000 MWt. If the power uprates is approved, a considerable cost benefit is expected. Therefore, regulatory demand for power uprates from the utility is anticipated in near future. The power uprates is not simply to change the design but to get it through assessments and analyses of overall systems of nuclear power plant. For this reason, the aims of this research is to present the need of preliminary provisions of relevant regulations considering the reassessment of the components integrity, the performance of components/systems, the accident analysis, and the technical specifications against the coming regulatory demand

  10. STAR Power, an Interactive Educational Fusion CD with a Dynamic, Shaped Tokamak Power Plant Simulator

    Science.gov (United States)

    Leuer, J. A.; Lee, R. L.; Kellman, A. G.; Chapman Nutt, G. C., Jr.; Holley, G.; Larsen, T. A.

    2000-10-01

    We describe an interactive, educational fusion adventure game developed within our fusion education program. The theme of the adventure is start-up of a state-of-the-art fusion power plant. To gain access to the power plant control room, the student must complete several education modules, including topics on building an atom, fusion reactions, charged particle motion in electric and magnetic fields, and building a power plant. Review questions, a fusion video, library material and glossary provide additional resources. In the control room the student must start-up a complex, dynamic fusion power plant. The simulation model contains primary elements of a tokamak based device, including a magnetic shaper capable of producing limited and diverted elongated plasmas. A zero dimensional plasma model based on ITER scaling and containing rate based conservation equations provides dynamic feedback through major control parameters such as toroidal field, fueling rate and heating. The game is available for use on PC and Mac. computers. Copies will be available at the conference.

  11. Extension of life of nuclear power stations

    International Nuclear Information System (INIS)

    Takahashi, Hideaki

    1991-01-01

    At the time of designing nuclear power stations, as their service life, generally 40 years are taken, and the basic design specifications of machinery and equipment are determined. In USA where atomic energy has been developed, the new construction of nuclear power stations is cased for a while, however, if this situation continues as it is, since old power stations reach the service life of 40 years and are retired in near future, it is feared that the circumstance of the total amount of power generation becoming short will occur. As one of the countermeasures to this, the research on the extension of life of nuclear power stations has been carried out in many fields in USA, and it is expected that the application for extending the life for the power stations constructed in the initial period of development is submitted in 1991. The researches that have been carried out for solving the technical problems in this extension of life and the situation in Japan are reported. The NEC of USA decided that the operation period of nuclear power stations in USA, which is considered to be 40 years so far, can be extended up to the limit of 20 years. The background and circumstances of this problem in USA, Nuclear Plant Aging Research Program, Plant Life Extension Program and so on are reported. (K.I.)

  12. Long Pulse EBW Start-up Experiments in MAST

    Directory of Open Access Journals (Sweden)

    Shevchenko V.F.

    2015-01-01

    Full Text Available Start-up technique reported here relies on a double mode conversion (MC for electron Bernstein wave (EBW excitation. It consists of MC of the ordinary (O mode, entering the plasma from the low field side of the tokamak, into the extraordinary (X mode at a mirror-polarizer located at the high field side. The X mode propagates back to the plasma, passes through electron cyclotron resonance (ECR and experiences a subsequent X to EBW MC near the upper hybrid resonance (UHR. Finally the excited EBW mode is totally absorbed at the Doppler shifted ECR. The absorption of EBW remains high even in cold rarefied plasmas. Furthermore, EBW can generate significant plasma current giving the prospect of a fully solenoid-free plasma start-up. First experiments using this scheme were carried out on MAST [1]. Plasma currents up to 33 kA have been achieved using 28 GHz 100kW 90ms RF pulses. Recently experimental results were extended to longer RF pulses showing further increase of plasma currents generated by RF power alone. A record current of 73kA has been achieved with 450ms RF pulse of similar power. The current drive enhancement was mainly achieved due to RF pulse extension and further optimisation of the start-up scenario.

  13. Effect of PWR Re-start ramp rate on pellet-cladding interactions

    International Nuclear Information System (INIS)

    Yagnik, S.K.; Chang, B.C.; Sunderland, D.J.

    2005-01-01

    To mitigate pellet-cladding interaction (PCI) leading to fuel rod failures, fuel suppliers specify reactor power ramp rate limitations during reactor start-up after an outage. Typical re-start ramp rates are restricted and range between 3-4% per hour of full reactor power above a threshold power level. Relaxation of threshold power and ramp rate restrictions has the potential to improve plant economics. The paper will compare known re-start power ascension procedures employed in the US, German, French and Korean PWRs after a refuelling outage. A technical basis for optimising power ascension procedures during reactor start-up can be developed using analytical modelling. The main objective of the modelling is to determine the potential for PCI failure for various combinations of threshold power levels and ramp rate levels. A key element of our analysis is to estimate the decrease in margin to cladding failure by ISCC based on a time-temperature-stress failure criterion fashioned Act a cumulative cladding damage index. The analysis approach and the cladding damage model will be described and the results from three case studies based on the FALCON fuel rod behaviour code will be reported. We conclude that the PCI behaviour is more affected by ramp rate and threshold power than by the fuel design and that the fuel power history is the most important parameter. (authors)

  14. Device for forecasting reactor power-up routes

    International Nuclear Information System (INIS)

    Fukuzaki, Takaharu.

    1980-01-01

    Purpose: To improve the reliability and forecasting accuracy for a device forecasting the change of the state on line in BWR type reactors. Constitution: The present state in a nuclear reactor is estimated in a present state judging section based on measuring signals for thermal power, core flow rate, control rod density and the like from the nuclear reactor, and the estimated results are accumulated in an operation result collecting section. While on the other hand, a forecasting section forecasts the future state in the reactor based on the signals from the forecasting condition setting section. The actual result values from the collecting section and the forecasting results are compared to each other. If they are not equal, new setting signals are outputted from the setting section to perform the forecasting again. These procedures are repeated till the difference between the forecast results and the actual result values is minimized, by which accurate forecasting for the state of the reactor is made possible. (Furukawa, Y.)

  15. Follow-Up After Cardiac Surgery Should be Extended to at Least 120 Days When Benchmarking Cardiac Surgery Centers.

    Science.gov (United States)

    Hansen, Laura S; Sloth, Erik; Hjortdal, Vibeke E; Jakobsen, Carl-Johan

    2015-08-01

    Short-term (30 days) mortality frequently is used as an outcome measure after cardiac surgery, although it has been proposed that the follow-up period should be extended to 120 days to allow for more accurate benchmarking. The authors aimed to evaluate whether mortality rates 120 days after surgery were comparable to general mortality and to compare causes of death between the cohort and the general population. A multicenter descriptive cohort study using prospectively entered registry data. University hospital. The cohort was obtained from the Western Denmark Heart Registry and matched to the Danish National Hospital Register as well as the Danish Register of Causes of Death. A weighted, age-matched general population consisting of all Danish patients who died within the study period was identified through the central authority on Danish statistics. A total of 11,988 patients (>15 years) who underwent cardiac-surgery at Aarhus, Aalborg and Odense University Hospitals from April 1, 2006 to December 31, 2012 were included. Coronary artery bypass grafting, valve surgery and combinations. Mortality after cardiac surgery matches with mortality in the general population after 140 days. Mortality curves run almost parallel from this point onwards, regardless of The European system for cardiac operative risk evaluation (EuroSCORE) and intervention. The causes of death in the cohort differed statistically significantly from the background population (pbenchmarking cardiac surgery centers. Regardless of preoperative heart function, heart failure was the consistent leading cause of death. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. Stability analysis of a power system made up of an intermittent renewable energy source directly tied to a conventional rotating power generator

    International Nuclear Information System (INIS)

    Coiante, D.

    1997-02-01

    A simple power system made up of a conventional rotating power generator in direct connection to an intermittent renewable energy source (with energy or photovoltaic) is modelled on the base of respective functional schemes. The relative variations of the voltage frequency are calculated as an output to an abrupt variation of intermittent tied power and in function of electro-mechanical parameters of the rotating generator (dumping coefficient and inertial rotor coefficient). The stability conditions and the tolerance allowed on the frequency variations are considered in relation to toad service requires. As a consequence, the maximum intermittent power amount, which can be accepted in direct connection, is obtained. For usual conventional rotating machines, the resulting limit is placed in the range of (12-19)% of nominal capacity of power generator

  17. Comparison Study on Empirical Correlation for Mass Transfer Coefficient with Gas Hold-up and Input Power of Aeration Process

    International Nuclear Information System (INIS)

    Park, Sang Kyoo; Yang, Hei Cheon

    2017-01-01

    As stricter environmental regulation have led to an increase in the water treatment cost, it is necessary to quantitatively study the input power of the aeration process to improve the energy efficiency of the water treatment processes. The objective of this study is to propose the empirical correlations for the mass transfer coefficient with the gas hold-up and input power in order to investigate the mass transfer characteristics of the aeration process. It was found that as the input power increases, the mass transfer coefficient increases because of the decrease of gas hold-up and increase of Reynolds number, the penetration length, and dispersion of mixed flow. The correlations for the volumetric mass transfer coefficients with gas hold-up and input power were consistent with the experimental data, with the maximum deviation less than approximately ±10.0%.

  18. Comparison Study on Empirical Correlation for Mass Transfer Coefficient with Gas Hold-up and Input Power of Aeration Process

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sang Kyoo; Yang, Hei Cheon [Chonnam Nat’l Univ., Gwangju (Korea, Republic of)

    2017-06-15

    As stricter environmental regulation have led to an increase in the water treatment cost, it is necessary to quantitatively study the input power of the aeration process to improve the energy efficiency of the water treatment processes. The objective of this study is to propose the empirical correlations for the mass transfer coefficient with the gas hold-up and input power in order to investigate the mass transfer characteristics of the aeration process. It was found that as the input power increases, the mass transfer coefficient increases because of the decrease of gas hold-up and increase of Reynolds number, the penetration length, and dispersion of mixed flow. The correlations for the volumetric mass transfer coefficients with gas hold-up and input power were consistent with the experimental data, with the maximum deviation less than approximately ±10.0%.

  19. Men are catching up with women in the life expectancy game.

    Science.gov (United States)

    2016-08-01

    One reason men are catching up is because of falling smoking rates. To give an idea of the powerful effect of smoking rates on mortality, 800,000 American deaths from lung cancer have been avoided because of the decline in smoking rates between 1975 and 2000.

  20. 76 FR 41238 - Post Rock Wind Power Project, LLC; Supplemental Notice That Initial Market-Based Rate Filing...

    Science.gov (United States)

    2011-07-13

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. ER11-3959-000] Post Rock Wind Power Project, LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes Request for... Rock Wind Power Project, LLC's application for market-based rate authority, with an accompanying rate...

  1. 76 FR 79169 - Power Network New Mexico, LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes...

    Science.gov (United States)

    2011-12-21

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. ER12-605-000] Power Network New Mexico, LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes Request for... Power Network New Mexico, LLC's application for market-based rate authority, with an accompanying rate...

  2. Estimation of leak rate through circumferential cracks in pipes in nuclear power plants

    Directory of Open Access Journals (Sweden)

    Jai Hak Park

    2015-04-01

    Full Text Available The leak before break (LBB concept is widely used in designing pipe lines in nuclear power plants. According to the concept, the amount of leaking liquid from a pipe should be more than the minimum detectable leak rate of a leak detection system before catastrophic failure occurs. Therefore, accurate estimation of the leak rate is important to evaluate the validity of the LBB concept in pipe line design. In this paper, a program was developed to estimate the leak rate through circumferential cracks in pipes in nuclear power plants using the Henry–Fauske flow model and modified Henry–Fauske flow model. By using the developed program, the leak rate was calculated for a circumferential crack in a sample pipe, and the effect of the flow model on the leak rate was examined. Treating the crack morphology parameters as random variables, the statistical behavior of the leak rate was also examined. As a result, it was found that the crack morphology parameters have a strong effect on the leak rate and the statistical behavior of the leak rate can be simulated using normally distributed crack morphology parameters.

  3. Framatome-ANP extended burnup experience and views on LWR fuels

    International Nuclear Information System (INIS)

    Esteve, B.; Gueldner, R.; Hoffman, R.; Watteau, M.

    2002-01-01

    In every sense of the term, nuclear fuel forms the core of nuclear power plants (NPPs). Although there are many equipment items important for their safety function or for their participation in NPP availability, the fuel, in essence renewable, is one of the key elements which have to be acted upon if utilities are to be helped to fulfil their mission of generating power in total safety and supplying the kWh to their customers at the best price. Nuclear fuel is also the core business of the Framatome-ANP Fuel Business Group: pooling and rationalising the available skills - technical, cultural and human - supplied by each of the partners forms a challenge which it is up to each and every one to meet in a cooperative spirit. This paper gives an outline of the company's extended burnup experience, current R and D, and its plans for the future. (author)

  4. Energy, electricity and nuclear power estimates for the period up to 2030. 2007 ed

    International Nuclear Information System (INIS)

    2007-01-01

    regional projections made by other international organizations. The nuclear generating capacity estimates presented are derived from a country by country 'bottom-up' approach. They are established by a group of experts participating each year in the IAEA's consultancy on Nuclear Capacity Projections and based upon a review of nuclear power projects and programmes in Member States. The low and high estimates reflect contrasting but not extreme underlying assumptions on the different driving factors that have an impact on nuclear power deployment. These factors, and the ways they might evolve, vary from country to country. The estimates presented provide a plausible range of nuclear capacity growth by region and worldwide. They are not intended to be predictive nor to reflect the whole range of possible futures from the lowest to the highest feasible. In the low estimates, the present barriers to nuclear power development are assumed to prevail in most countries during the coming three decades: - Low economic and electricity demand growth rates in OECD countries; - Public opposition to nuclear power, leading to policy decisions not to consider the nuclear option in spite of its competitive costs and potential contribution to reducing environmental impacts from electricity generation; - Institutional and financing issues preventing the implementation of previously planned nuclear programmes, in particular in countries in transition and in developing countries; - Inadequate mechanisms for nuclear technology transfer and nuclear project funding in developing countries. The high estimates reflect a moderate revival of nuclear power development that could result in particular from a more comprehensive comparative assessment of the different options for electricity generation, integrating economic, social, health and environmental aspects. They are based upon a review of national nuclear power programmes, assessing their technical and economic feasibility. They assume that some

  5. Establishment of an inferior vena cava filter database and interventional radiology led follow-up - retrieval rates and patients lost to follow-up.

    Science.gov (United States)

    Klinken, Sven; Humphries, Charlotte; Ferguson, John

    2017-10-01

    To evaluate the rates of inferior vena cava (IVC) filter retrieval and the number of patient's lost to follow-up, before and after the establishment of an IVC filter database and interventional radiology (inserting physician) led follow-up. On the 1st of June 2012, an electronic interventional radiology database was established at our Institution. In addition, the interventional radiology team took responsibility for follow-up of IVC filters. Data were prospectively collected from the database for all patients who had an IVC filter inserted between the 1st June 2012 and the 31st May 2014. Data on patients who had an IVC filter inserted between the 1st of June 2009 to the 31st of May 2012 were retrospectively reviewed. Patient demographics, insertion indications, filter types, retrieval status, documented retrieval decisions, time in situ, trackable events and complications were obtained in the pre-database (n = 136) and post-database (n = 118) cohorts. Attempted IVC filter retrieval rates were improved from 52.9% to 72.9% (P = 0.001) following the establishment of the database. The number of patients with no documented decision (lost to follow-up) regarding their IVC filter reduced from 31 of 136 (23%) to 0 of 118 patients (P = database group (113 as compared to 137 days, P = 0.129). Following the establishment of an IVC filter database and interventional radiology led follow-up, we demonstrate a significant improvement in the attempted retrieval rates of IVC filters and the number of patient's lost to follow-up. © 2017 The Royal Australian and New Zealand College of Radiologists.

  6. Extended fuel cycle operation for pressurized water reactor plants

    International Nuclear Information System (INIS)

    Silvestri, G.J. Jr.

    1978-01-01

    A nuclear steam turbine power plant system having an arrangement therein for extended fuel cycle operation is described. The power plant includes a turbine connected at its inlet to a source of motive fluid having a predetermined pressure associated therewith. The turbine has also connected thereto an extraction conduit which extracts steam from a predetermined location therein for use in an associated apparatus. A bypass conduit is provided between a point upstream of the inlet and the extraction conduit. A flow control device is provided within the bypass conduit and opens when the pressure of the motive steam supply drops beneath the predetermined pressure as a result of reactivity loss within the nuclear reactor. Opening of the bypass conduit provides flow to the associated apparatus and at the same time provides an increased flow orifice to maintain fluid flow rate at a predetermined level

  7. Rating PV Power and Energy: Cell, Module, and System Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Emery, Keith

    2016-06-02

    A summary of key points related to research-level measurements of current vs. voltage measurement theory including basic PV operation, equivalent circuit, and concept of spectral error; PV power performance including PV irradiance sensors, simulators and commercial and generic I-V systems; PV measurement artifacts, intercomparisons, and alternative rating methods.

  8. High-Frame-Rate Power Doppler Ultrasound Is More Sensitive than Conventional Power Doppler in Detecting Rheumatic Vascularisation

    NARCIS (Netherlands)

    M. van der Ven (Myrthe); J.J. Luime (Jolanda); van der Velden, L.L. (Levinia L.); J.G. Bosch (Hans); J.M.W. Hazes (Mieke); H.J. Vos (Rik)

    2016-01-01

    textabstractEarly recognition of joint inflammation will increase treatment efficacy in rheumatoid arthritis (RA). Yet, conventional power Doppler (PD) ultrasound might not be sufficiently sensitive to detect minor inflammation. We investigated the sensitivity of high-frame rate Doppler, combined

  9. 75 FR 42745 - Hardscrabble Wind Power LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes...

    Science.gov (United States)

    2010-07-22

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. ER10-1725-000] Hardscrabble Wind Power LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes Request for Blanket... of Hardscrabble Wind Power LLC's application for market-based rate authority, with an accompanying...

  10. 77 FR 55817 - Panther Creek Power Operating, LLC; Supplemental Notice that Initial Market-Based Rate Filing...

    Science.gov (United States)

    2012-09-11

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. ER12-2570-000] Panther Creek Power Operating, LLC; Supplemental Notice that Initial Market-Based Rate Filing Includes Request for... Panther Creek Power Operating, LLC's application for market-based rate authority, with an accompanying...

  11. 78 FR 28835 - Salton Sea Power Generation Company; Supplemental Notice That Initial Market-Based Rate Filing...

    Science.gov (United States)

    2013-05-16

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. ER13-1271-000] Salton Sea Power Generation Company; Supplemental Notice That Initial Market-Based Rate Filing Includes Request for... Salton Sea Power Generation Company's application for market-based rate authority, with an accompanying...

  12. Xenon Acquisition Strategies for High-Power Electric Propulsion NASA Missions

    Science.gov (United States)

    Herman, Daniel A.; Unfried, Kenneth G.

    2015-01-01

    The benefits of high-power solar electric propulsion (SEP) for both NASA's human and science exploration missions combined with the technology investment from the Space Technology Mission Directorate have enabled the development of a 50kW-class SEP mission. NASA mission concepts developed, including the Asteroid Redirect Robotic Mission, and those proposed by contracted efforts for the 30kW-class demonstration have a range of xenon propellant loads from 100's of kg up to 10,000 kg. A xenon propellant load of 10 metric tons represents greater than 10% of the global annual production rate of xenon. A single procurement of this size with short-term delivery can disrupt the xenon market, driving up pricing, making the propellant costs for the mission prohibitive. This paper examines the status of the xenon industry worldwide, including historical xenon supply and pricing. The paper discusses approaches for acquiring on the order of 10 MT of xenon propellant considering realistic programmatic constraints to support potential near-term NASA missions. Finally, the paper will discuss acquisitions strategies for mission campaigns utilizing multiple high-power solar electric propulsion vehicles requiring 100's of metric tons of xenon over an extended period of time where a longer term acquisition approach could be implemented.

  13. EC assisted start-up experiments reproduction in FTU and AUG for simulations of the ITER case

    Energy Technology Data Exchange (ETDEWEB)

    Granucci, G.; Ricci, D.; Farina, D.; Figini, L. [Associazione EURATOM-ENEA sulla Fusione, IFP-CNR, Via R. Cozzi 53, 20125 Milano (Italy); Cavinato, M. [F4E C/Josep Pla2, Torres Diagonal Litoral - Building 83 08019 Barcelona (Spain); Mattei, M. [CREATE via Claudio 21, 80125 Napoli (Italy); Stober, J. [Max-Planck-Institut für Plasmaphysik, EURATOM Association, Boltzmannstr. 2, 85748 Garching bei München (Germany); Tudisco, O. [Associazione EURATOM-ENEA sulla Fusione, C.R. Frascati, Via E. Fermi 45, 00044 Frascati (Roma) (Italy)

    2014-02-12

    The breakdown and plasma start-up in ITER are well known issues studied in the last few years in many tokamaks with the aid of calculation based on simplified modeling. The thickness of ITER metallic wall and the voltage limits of the Central Solenoid Power Supply strongly limit the maximum toroidal electric field achievable (0.3 V/m), well below the level used in the present generation of tokamaks. In order to have a safe and robust breakdown, the use of Electron Cyclotron Power to assist plasma formation and current rump up has been foreseen. This has raised attention on plasma formation phase in presence of EC wave, especially in order to predict the required power for a robust breakdown in ITER. Few detailed theory studies have been performed up to nowadays, due to the complexity of the problems. A simplified approach, extended from that proposed in ref[1] has been developed including a impurity multispecies distribution and an EC wave propagation and absorption based on GRAY code. This integrated model (BK0D) has been benchmarked on ohmic and EC assisted experiments on FTU and AUG, finding the key aspects for a good reproduction of data. On the basis of this, the simulation has been devoted to understand the best configuration for ITER case. The dependency of impurity distribution content and neutral gas pressure limits has been considered. As results of the analysis a reasonable amount of power (1 - 2 MW) seems to be enough to extend in a significant way the breakdown and current start up capability of ITER. The work reports the FTU data reproduction and the ITER case simulations.

  14. Prediction on corrosion rate of pipe in nuclear power system based on optimized grey theory

    International Nuclear Information System (INIS)

    Chen Yonghong; Zhang Dafa; Chen Dengke; Jiang Wei

    2007-01-01

    For the prediction of corrosion rate of pipe in nuclear power system, the pre- diction error from the grey theory is greater, so a new method, optimized grey theory was presented in the paper. A comparison among predicted results from present and other methods was carried out, and it is seem that optimized grey theory is correct and effective for the prediction of corrosion rate of pipe in nuclear power system, and it provides a fundamental basis for the maintenance of pipe in nuclear power system. (authors)

  15. Extended mind and after: socially extended mind and actor-network.

    Science.gov (United States)

    Kono, Tetsuya

    2014-03-01

    The concept of extended mind has been impressively developed over the last 10 years by many philosophers and cognitive scientists. The extended mind thesis (EM) affirms that the mind is not simply ensconced inside the head, but extends to the whole system of brain-body-environment. Recently, some philosophers and psychologists try to adapt the idea of EM to the domain of social cognition research. Mind is socially extended (SEM). However, EM/SEM theory has problems to analyze the interactions among a subject and its surroundings with opposition, antagonism, or conflict; it also tends to think that the environment surrounding the subject is passive or static, and to neglect the power of non-human actants to direct and regulate the human subject. In these points, actor-network theory (ANT) proposed by Latour and Callon is more persuasive, while sharing some important ideas with EM/SEM theory. Actor-network is a hybrid community which is composed of a series of heterogeneous elements, animate and inanimate for a certain period of time. I shall conclude that EM/SEM could be best analyzed as a special case of actor-network. EM/SEM is a system which can be controlled by a human agent alone. In order to understand collective behavior, philosophy and psychology have to study the actor-network in which human individuals are situated.

  16. Design and evaluation of nicorandil extended-release tablet

    Directory of Open Access Journals (Sweden)

    Ju-Young Kim

    2015-04-01

    Full Text Available The aim of this study was to design and evaluate extended-release formulations of a model drug, nicorandil, in order to achieve the desired steady-state plasma concentration of drug in vivo. Simulation was employed to estimate optimum dissolution and absorption rate of nicorandil. The dissolution test was employed using pH 1.2, 4.0, 6.8 buffer solution, or water, to measure the in vitro release behaviors of nicorandil formulations. A single dose (15 mg of each formulation was orally administered to four beagle dogs under fasted conditions, and the pharmacokinetic parameters were calculated. The in vitro/in vivo relationship of the extended-release formulation was confirmed using in vitro dissolution profiles and plasma concentrations of drug in beagle dogs. Nicorandil was released completely within 30 min from the immediate-release tablets and released for 24 h from the extended-release tablets. The nicorandil plasma concentration could be modified by adjusting the drug release rate from the extended-release formulation. The release rate of nicorandil was the rate-limiting step in the overall absorption of drug from the extended-release formulations. These results highlight the potential of a nicorandil extended-release formulation in the treatment of angina pectoris.

  17. ICU Acquisition Rate, Risk Factors, and Clinical Significance of Digestive Tract Colonization With Extended-Spectrum Beta-Lactamase-Producing Enterobacteriaceae: A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Detsis, Marios; Karanika, Styliani; Mylonakis, Eleftherios

    2017-04-01

    To evaluate the acquisition rate, identify risk factors, and estimate the risk for subsequent infection, associated with the colonization of the digestive tract with extended-spectrum beta-lactamase-producing Enterobacteriaceae during ICU-hospitalization. PubMed, EMBASE, and reference lists of all eligible articles. Included studies provided data on ICU-acquired colonization with extended-spectrum beta-lactamase-producing Enterobacteriaceae in previously noncolonized and noninfected patients and used the double disk synergy test for extended-spectrum beta-lactamase-producing Enterobacteriaceae phenotypic confirmation. Studies reporting extended-spectrum beta-lactamase-producing Enterobacteriaceae outbreaks or data on pediatric population were excluded. Two authors independently assessed study eligibility and performed data extraction. Thirteen studies (with 15,045 ICUs-patients) were evaluated using a random-effect model and a meta-regression analysis. The acquisition rate of digestive tract colonization during ICU stay was 7% (95% CI, 5-10) and it varies from 3% (95% CI, 2-4) and 4% (95% CI, 2-6) in the Americas and Europe to 21% (95% CI, 9-35) in the Western Pacific region. Previous hospitalization (risk ratio, 1.57 [95% CI, 1.07-2.31]) or antibiotic use (risk ratio, 1.65 [95% CI, 1.15-2.37]) and exposure to beta-lactams/beta-lactamase inhibitors (risk ratio, 1.78 [95% CI, 1.24-2.56]) and carbapenems (risk ratio, 2.13 [95% CI, 1.49-3.06]) during the ICU stay were independent risk factors for ICU-acquired colonization. Importantly, colonized patients were more likely to develop an extended-spectrum beta-lactamase-producing Enterobacteriaceae infection (risk ratio, 49.62 [95% CI, 20.42-120.58]). The sensitivity and specificity of prior colonization to predict subsequent extended-spectrum beta-lactamase-producing Enterobacteriaceae infection were 95.1% (95% CI, 54.7-99.7) and 89.2% (95% CI, 77.2-95.3), respectively. The ICU acquisition rate of extended-spectrum beta

  18. Power-up of Fugen reactor and development of demonstration plant

    International Nuclear Information System (INIS)

    Sawai, Sadamu; Akebi, Michio; Yazaki, Akira.

    1979-06-01

    The Fugen Nuclear Power Station is the 165 MWe prototype plant characterized by heavy water-moderated, boiling light water-cooled, pressure tube type, and was developed by the Power Reactor and Nuclear Fuel Development Corporation, Japan. The plant went into commercial operation on March 20, 1979, in Tsuruga, Fukui Prefecture. Some delay in the overall schedule occurred due to the shortage of cement caused by the oil crisis, more stringent regulations as the result of stress corrosion cracking experienced in BWRs, and design modifications. All functional tests, the final check-up of the whole plant, and remaining modifying works had been completed by March 10, 1978. The minimum criticality was achieved with 22 mixed oxide fuel assemblies on March 20, 1978. Thereafter, the tests on reactor physics, plant dynamics, the performances of components and systems, and radiation and water chemistry have been carried out. 5 MWe was sent to grid system for the first time on July 29, 1978. The commercial operation of the plant was licenced by the Government on March 30, 1979. The conceptual design of the 600 MWe demonstration plant was finished in early 1979, and the detailed design is to be carried out in 1979 and 1980. The main design principle was incorporated in the conceptual design, but some modifications are to be made to reduce the power cost and to facilitate the easy maintenance. (Kako, I.)

  19. Fluorescence decay data analysis correcting for detector pulse pile-up at very high count rates

    Science.gov (United States)

    Patting, Matthias; Reisch, Paja; Sackrow, Marcus; Dowler, Rhys; Koenig, Marcelle; Wahl, Michael

    2018-03-01

    Using time-correlated single photon counting for the purpose of fluorescence lifetime measurements is usually limited in speed due to pile-up. With modern instrumentation, this limitation can be lifted significantly, but some artifacts due to frequent merging of closely spaced detector pulses (detector pulse pile-up) remain an issue to be addressed. We propose a data analysis method correcting for this type of artifact and the resulting systematic errors. It physically models the photon losses due to detector pulse pile-up and incorporates the loss in the decay fit model employed to obtain fluorescence lifetimes and relative amplitudes of the decay components. Comparison of results with and without this correction shows a significant reduction of systematic errors at count rates approaching the excitation rate. This allows quantitatively accurate fluorescence lifetime imaging at very high frame rates.

  20. Watts Up? Pro AC Power Meter for Automated Energy Recording: A Product Review

    OpenAIRE

    Hirst, Jason M.; Miller, Jonathan R.; Kaplan, Brent A.; Reed, Derek D.

    2013-01-01

    The purpose of the present paper is to review the Watts up? Pro AC power meter. Evaluations of the meter's reliability for measuring energy consumption by consumer electronics yielded acceptable levels of reliability. Implications and limitations for the use of this product in behavior analytic research and practice are discussed.

  1. Follow-up, treatment, and reinfection rates among asymptomatic Chlamydia trachomatis cases in general practice

    NARCIS (Netherlands)

    Van Valkengoed, Irene G.M.; Morré, Servaas A.; Van Den Brule, Adriaan J.C.; Meijer, Chris J.L.M.; Bouter, Lex M.; Van Eijk, Jacques Th M.; Boeke, A. Joan P.

    2002-01-01

    Background: Adequate treatment and follow-up of patients is essential to the success of a screening programme for Chlamydia trachomatis. There has been a lack of data on follow-up, confirmation of infections, and reinfection rates among asymptomatic patients in general practice. Aim: To study the

  2. Follow-up, treatment, and reinfection rates among asymptomatic Chlamydia trachomatis cases in general practice

    NARCIS (Netherlands)

    Van Valkengoed, Irene G.M.; Morré, Servaas A.; Van Den Brule, Adriaan J.C.; Meijer, Chris J.L.M.; Bouter, Lex M.; Van Eijk, Jacques Th M.; Boeke, A. Joan P.

    2002-01-01

    BACKGROUND: Adequate treatment and follow-up of patients is essential to the success of a screening programme for Chlamydia trachomatis. There has been a lack of data on follow-up, confirmation of infections, and reinfection rates among asymptomatic patients in general practice. AIM: 7b study the

  3. Follow-up, treatment, and reinfection rates among asymptomatic chlamydia trachomatis cases in general practice

    NARCIS (Netherlands)

    van Valkengoed, Irene G. M.; Morré, Servaas A.; van den Brule, Adriaan J. C.; Meijer, Chris J. L. M.; Bouter, Lex M.; van Eijk, Jacques Th M.; Boeke, A. Joan P.

    2002-01-01

    BACKGROUND: Adequate treatment and follow-up of patients is essential to the success of a screening programme for Chlamydia trachomatis. There has been a lack of data on follow-up, confirmation of infections, and reinfection rates among asymptomatic patients in general practice. AIM: 7b study the

  4. Power-up: A Reanalysis of 'Power Failure' in Neuroscience Using Mixture Modeling.

    Science.gov (United States)

    Nord, Camilla L; Valton, Vincent; Wood, John; Roiser, Jonathan P

    2017-08-23

    Recently, evidence for endemically low statistical power has cast neuroscience findings into doubt. If low statistical power plagues neuroscience, then this reduces confidence in the reported effects. However, if statistical power is not uniformly low, then such blanket mistrust might not be warranted. Here, we provide a different perspective on this issue, analyzing data from an influential study reporting a median power of 21% across 49 meta-analyses (Button et al., 2013). We demonstrate, using Gaussian mixture modeling, that the sample of 730 studies included in that analysis comprises several subcomponents so the use of a single summary statistic is insufficient to characterize the nature of the distribution. We find that statistical power is extremely low for studies included in meta-analyses that reported a null result and that it varies substantially across subfields of neuroscience, with particularly low power in candidate gene association studies. Therefore, whereas power in neuroscience remains a critical issue, the notion that studies are systematically underpowered is not the full story: low power is far from a universal problem. SIGNIFICANCE STATEMENT Recently, researchers across the biomedical and psychological sciences have become concerned with the reliability of results. One marker for reliability is statistical power: the probability of finding a statistically significant result given that the effect exists. Previous evidence suggests that statistical power is low across the field of neuroscience. Our results present a more comprehensive picture of statistical power in neuroscience: on average, studies are indeed underpowered-some very seriously so-but many studies show acceptable or even exemplary statistical power. We show that this heterogeneity in statistical power is common across most subfields in neuroscience. This new, more nuanced picture of statistical power in neuroscience could affect not only scientific understanding, but potentially

  5. Study on the sensitivity of Self-Powered Neutron Detectors (SPND) and its change due to burn-up

    International Nuclear Information System (INIS)

    Cho, Gyuseong; Lee, Wanno; Yoon, Jeong-Hyoun.

    1996-01-01

    Self-Powered Neutron Detectors (SPND) are currently used to estimate the power generation distribution and fuel burn-up in several nuclear power reactors in Korea. While they have several advantages such as small size, low cost, and relatively simple electronics required in conjunction with its usage, it has some intrinsic problems of the low level of output current, a slow response time, the rapid change of sensitivity which makes it difficult to use for a long term. In this paper, Monte Carlo simulation was accomplished to calculate the escape probability as a function of the birth position for the typical geometry of rhodium-based SPNDs. Using the simulation result, the burn-up profile of rhodium number density and the neutron sensitivity is calculated as a function of burn-up time in the reactor. The sensitivity of the SPND decreases non-linearly due to the high absorption cross-section and the non-uniform burn-up of rhodium in the emitter rod. The method used here can be applied to the analysis of other types of SPNDs and will be useful in the optimum design of new SPNDs for long-term usage. (author)

  6. Energy, electricity and nuclear power estimates for the period up to 2030. July 2005 ed

    International Nuclear Information System (INIS)

    2005-01-01

    global and regional projections made by other international organizations. The nuclear generating capacity estimates presented are derived from a country by country bottom-up approach. They are established by a group of experts participating each year in the IAEA's consultancy on Nuclear Capacity Projections and based upon a review of nuclear power projects and programmes in Member States. The low and high estimates reflect contrasting but not extreme underlying assumptions on the different driving factors that have an impact on nuclear power deployment. These factors, and the ways they might evolve, vary from country to country. The estimates presented provide a plausible range of nuclear capacity growth by region and worldwide. They are not intended to be predictive nor to reflect the whole range of possible futures from the lowest to the highest feasible. In the low estimates, the present barriers to nuclear power development are assumed to prevail in most countries during the coming three decades: - Low economic and electricity demand growth rates in OECD countries; - Public opposition to nuclear power, leading to policy decisions not to consider the nuclear option in spite of its competitive costs and potential contribution to reducing environmental impacts from electricity generation; - Institutional and financing issues preventing the implementation of previously planned nuclear programmes, in particular in countries in transition and in developing countries; - Inadequate mechanisms for nuclear technology transfer and nuclear project funding in developing countries. The high estimates reflect a moderate revival of nuclear power development that could result in particular from a more comprehensive comparative assessment of the different options for electricity generation, integrating economic, social, health and environmental aspects. They are based upon a review of national nuclear power programmes, assessing their technical and economic feasibility. They assume

  7. Power scaling of supercontinuum seeded megahertz-repetition rate optical parametric chirped pulse amplifiers.

    Science.gov (United States)

    Riedel, R; Stephanides, A; Prandolini, M J; Gronloh, B; Jungbluth, B; Mans, T; Tavella, F

    2014-03-15

    Optical parametric chirped-pulse amplifiers with high average power are possible with novel high-power Yb:YAG amplifiers with kW-level output powers. We demonstrate a compact wavelength-tunable sub-30-fs amplifier with 11.4 W average power with 20.7% pump-to-signal conversion efficiency. For parametric amplification, a beta-barium borate crystal is pumped by a 140 W, 1 ps Yb:YAG InnoSlab amplifier at 3.25 MHz repetition rate. The broadband seed is generated via supercontinuum generation in a YAG crystal.

  8. 75 FR 18201 - Juniper Canyon Wind Power, LLC; Supplemental Notice That Initial Market-Based Rate Filing...

    Science.gov (United States)

    2010-04-09

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. ER10-975-000] Juniper Canyon Wind Power, LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes Request for Blanket... of Juniper Canyon Wind Power, LLC's application for market-based rate authority, with an accompanying...

  9. 76 FR 2368 - Balance Power Systems, LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes...

    Science.gov (United States)

    2011-01-13

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. ER11-2331-000] Balance Power Systems, LLC; Supplemental Notice That Initial Market-Based Rate Filing Includes Request for Blanket... proceeding of Balance Power Systems, LLC's application for market-based rate authority, with an accompanying...

  10. CHF during flow rate, pressure and power transients in heated channels

    International Nuclear Information System (INIS)

    Celata, G.P.; Cumo, M.

    1987-01-01

    The behaviour of forced two-phase flows following inlet flow rate, pressure and power transients is presented here with reference to experiments performed with a R-12 loop. A circular duct, vertical test section (L = 2300 mm; D = 7.5 mm) instrumented with fluid (six) and wall (twelve) thermocouples has been employed. Transients have been carried out performing several values of flow decays (exponential decrease), depressurization rates (exponential decrease) and power inputs (step-wise increase). Experimental data have shown the complete inadequacy of steady-state critical heat flux correlations in predicting the onset of boiling crisis during fast transients. Data analysis for a better theoretical prediction of CHF occurrence during transient conditions has been accomplished, and design correlations for critical heat flux and time-to-crisis predictions have been proposed for the different types of transients

  11. Extended long term functional outcome of inflatable penile prosthesis in a single institution.

    LENUS (Irish Health Repository)

    Thomas, A Z

    2011-02-01

    We sought to evaluate the extended long term functional outcome of the AMS700 three piece inflatable prosthesis in men with erectile dysfunction in a single urological department and assess our revision rates. Patients that underwent first-time insertion or revision of an AMS700 3 piece inflatable penile prosthesis between 1984-2007 were included. Data was obtained from medical records and long term follow up of patients was conducted by telephone interview. The medical records of 38 patients were available for review. Of these 38 men, 56 prostheses were inserted. The mean follow up was 8.4 years (101 months). The revision rate at 50 months postoperatively was 7\\/38 (18%). The overall revision rate was 18\\/38 (47%). The mean time to revision in these 18 patients was 72 months (12-156 months) after initial insertion of AMS700 penile prosthesis. This study highlights that with longer follow u revision rates markedly increase after 72 months.

  12. The specification of cross exchange rate equations used to test Purchasing Power Parity

    OpenAIRE

    Hunter, J; Simpson, M

    2004-01-01

    The Article considers the speciÞcation of models used to test Pur- chasing Power Parity when applied to cross exchange rates. SpeciÞcally, conventional dynamic models used to test stationarity of the real exchange rate are likely to be misspeciÞed, except when the parameters of each ex- change rate equation are the same

  13. Government borrowing and the long-term interest rate: Application of an extended loanable funds model to the Slovak Republic

    Directory of Open Access Journals (Sweden)

    Hsing Yu

    2010-01-01

    Full Text Available Extending the open-economy loanable funds model, this paper finds that more government borrowing as a percent of GDP leads to a higher government bond yield, that a higher real money market rate, a higher expected inflation rate, a higher EU government bond yield, or a decrease in the Slovak nominal effective exchange rate would increase the Slovak government bond yield, and that the positive coefficient of the percent change in real GDP is insignificant at the 10% level. When the standard closedeconomy or open-economy loanable funds model is considered, except that the positive coefficient of the ratio of the net capital inflow to GDP is insignificant at the 10% level, other results are similar.

  14. Combined Rate and Power Allocation with Link Scheduling in Wireless Data Packet Relay Networks with Fading Channels

    Directory of Open Access Journals (Sweden)

    Subhrakanti Dey

    2007-08-01

    Full Text Available We consider a joint rate and power control problem in a wireless data traffic relay network with fading channels. The optimization problem is formulated in terms of power and rate selection, and link transmission scheduling. The objective is to seek high aggregate utility of the relay node when taking into account buffer load management and power constraints. The optimal solution for a single transmitting source is computed by a two-layer dynamic programming algorithm which leads to optimal power, rate, and transmission time allocation at the wireless links. We further consider an optimal power allocation problem for multiple transmitting sources in the same framework. Performances of the resource allocation algorithms including the effect of buffer load control are illustrated via extensive simulation studies.

  15. An approach of raising the low power reactor trip block (P-7) in Maanshan Power Plant

    International Nuclear Information System (INIS)

    Wang, L.C.

    1984-01-01

    The technical specification for the Maanshan Nuclear Power Station (FSAR Table 16.2.2-3) requires that with an increasing reactor power level above the setpoint of low power reactor trip block (P-7), a turbine trip shall initiate a reactor trip. This anticipatory reactor trip on turbine trip prevents the pressurizer PORV from openning during turbine trip event. In order to reduce unnecessary reactor trip due to turbine trip on low reactor power level during Maanshan start-up stage, Taiwan Power Company performed a transient analysis for turbine trip event by using RETRAN code. The highest reactor power level at which a turbine trip will not open the pressurizer PORV is searched. The results demonstrated that this power level can be increased from the original value-10% of the rated thermal power-to about 48% of the rated thermal power

  16. Extended Pulse-Powered Humidity-Freeze Cycling for Testing Module-Level Power Electronics

    Energy Technology Data Exchange (ETDEWEB)

    Hacke, Peter L [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Rodriguez, Miguel [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Kempe, Michael D [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Repins, Ingrid L [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-11-28

    An EMI suppression capacitor (polypropylene film type) failed by 'popcorning' due to vapor outgassing in pulse powered humidity-freeze cycles. No shorts or shunts could be detected despite mildly corroded metallization visible in the failed capacitor. Humidity-freeze cycling is optimized to break into moisture barriers. However, further studies will be required on additional module level power electronic (MLPE) devices to optimize the stress testing for condensation to precipitate any weakness to short circuiting and other humidity/bias failure modes.

  17. Joint sensor location/power rating optimization for temporally-correlated source estimation

    KAUST Repository

    Bushnaq, Osama M.; Chaaban, Anas; Al-Naffouri, Tareq Y.

    2017-01-01

    via wireless AWGN channel. In addition to selecting the optimal sensing location, the sensor type to be placed in these locations is selected from a pool of T sensor types such that different sensor types have different power ratings and costs

  18. Power start up of the Dalat nuclear research reactor; Khoi dong nang luong lo phan ung hat nhan Da Lat

    Energy Technology Data Exchange (ETDEWEB)

    Hien, Pham Duy; Huy, Ngo Quang; Long, Vu Hai; Mai, Tran Khanh [Nuclear Research Inst., Da Lat (Viet Nam)

    1994-10-01

    After accomplishing the physical start-up of the reactor, the power start-up was carried out in February 1984. The power of the reactor has reached: 10 KW on 6/2/1984, 100 KW on 7/2/1984, 200 KW and 300 KW on 8/2/1984; 400 KW and nominal power 500 KW on 9/2/1984. The reactivity temperature coefficient and the xenon poisoning were determined. 3 figs., 12 tabs.

  19. On the Reconciliation of the Extended Nelson-Siegel and the Extended Vasicek Models (with a View Towards Swap and Swaption Valuation)

    DEFF Research Database (Denmark)

    Jørgensen, Peter Løchte

    Extended Nelson-Siegel models are widely used by e.g. practitioners and central banks to estimate current term structures of riskless zero-coupon interest rates, whereas other models such as the extended Vasicek model (a.k.a. the Hull-White model) are popular for pricing interest rate derivatives....... This paper establishes theoretical consistency between these two types of models by showing how to specify the extended Vasicek model such that its implied initial term structure curve precisely matches a given extended Nelson-Siegel specification. That is, we show how to reconcile the two classes of models...

  20. Scale-up of mixer-settler for uranium extraction; Determinacao das relacoes de `scale-up` em misturador-decantador tipo caixa utilizado na extracao de uranio

    Energy Technology Data Exchange (ETDEWEB)

    Santana, A.O. de

    1990-05-01

    The aim of this work was to obtain scale-up relations for a box type mixer-settler used in uranium extraction process for chloridric leaches. Three box type units with different sizes and with the same geometry were used for scale-up of the mixer. The correlation between extraction rate and specific power input, D/T ratio (stirrer diameter/mixer length) and residence time were experimentally obtained. The results showed that the extraction increases with power input for a constant value of D/T equal to 1/3, remaining however independent from mixer sizes for a specific value of power input. This behavior was observed for power input values ranging from 100 to 750 w/m{sup 9}. (author). 23 refs, 22 figs, 23 tabs.

  1. Does increasing active warm-up duration affect afternoon short-term maximal performance during Ramadan?

    Science.gov (United States)

    Baklouti, Hana; Aloui, Asma; Chtourou, Hamdi; Briki, Walid; Chaouachi, Anis; Souissi, Nizar

    2015-01-01

    The purpose of this study was to examine the effect of active warm-up duration on short-term maximal performance assessed during Ramadan in the afternoon. Twelve healthy active men took part in the study. The experimental design consisted of four test sessions conducted at 5 p.m., before and during Ramadan, either with a 5-minute or a 15-minute warm-up. The warm-up consisted in pedaling at 50% of the power output obtained at the last stage of a submaximal multistage cycling test. During each session, the subjects performed two vertical jump tests (squat jump and counter movement jump) for measurement of vertical jump height followed by a 30-second Wingate test for measurement of peak and mean power. Oral temperature was recorded at rest and after warming-up. Moreover, ratings of perceived exertion were obtained immediately after the Wingate test. Oral temperature was higher before Ramadan than during Ramadan at rest, and was higher after the 15-minute warm-up than the 5-minute warm-up both before and during Ramadan. In addition, vertical jump heights were not significantly different between the two warm-up conditions before and during Ramadan, and were lower during Ramadan than before Ramadan after both warm-up conditions. Peak and mean power were not significantly different between the two warm-up durations before Ramadan, but were significantly higher after the 5-minute warm-up than the 15-minute warm-up during Ramadan. Moreover, peak and mean power were lower during Ramadan than before Ramadan after both warm-up conditions. Furthermore, ratings of perceived exertion were higher after the 15-minute warm-up than the 5-minute warm-up only during Ramadan. The prolonged active warm-up has no effect on vertical jump height but impairs anaerobic power assessed during Ramadan in the afternoon.

  2. Cash Flow and Discount Rate Risk in Up and Down Markets: What is actually priced?

    NARCIS (Netherlands)

    Botshekan, M.; Kraeussl, R.G.W.; Lucas, A.

    2012-01-01

    We test whether asymmetric preferences for losses versus gains affect the prices of cash flow versus discount rate risk. We construct a return decomposition distinguishing cash flow and discount rate betas in up and down markets. Using U.S. data, we find that downside cash flow and discount rate

  3. The fecundity of porcine semen stored for 2 to 6 days in Androhep and X-CELL extenders.

    Science.gov (United States)

    Kuster, C E; Althouse, G C

    1999-08-01

    Extending the raw ejaculate prior to artificial insemination (AI) is beneficial, in part, due to the increased number of females that are bred from an ejaculate, along with prolonged shelf life of the semen. The objective of this study was to examine the affects of storage time on the fecundity of porcine semen diluted in 2 semen extenders, Androhep and X-CELL. A completely randomized design with a factorial arrangement of treatments was utilized in which 429 high quality, gel-free ejaculates from 48 boars were used in a timed, double insemination of 1,431 first-service gilts. The gilts were divided into groups and inseminated with semen stored in Androhep or X-CELL for 2 to 3 d, 3 to 4 d, 4 to 5 d, or 5 to 6 d prior to use (day of collection = Day 0). Sperm age was identical, and both extenders were used concurrently each day of the trial. Farrowing rate and litter size data were recorded. Farrowing rates did not differ between extenders through Days 4 to 5 of storage. Gilts inseminated with Androhep diluted stored semen showed a decrease (P semen extended in X-CELL stored for 5 to 6 d. Mean litter sizes did not differ between extenders through Days 2 to 3 of storage. Compared with the X-CELL extended semen, gilts inseminated with Androhep extended semen produced smaller litters when semen was stored for 4 to 5 d (P semen was stored for 3 to 4 and 4 to 5 d. No differences were detected in litter size or farrowing rate for gilts bred with semen stored for 2 to 6 d in the X-CELL extender (P > 0.1). The results of this study indicate that extender type influences the fertility potential of fresh porcine semen stored for 2 to 6 d. For optimal fecundity in gilts, semen extended with Androhep extender should be used for AI within 3 d. The X-CELL extended semen can be used for up to 6 d without significant decrease in litter size or farrowing rate. These recommendations are dependent upon using high quality semen that is properly handled from collection through

  4. Volatile amines treatment: Corrosion rates and Atucha I nuclear power plant experience

    International Nuclear Information System (INIS)

    Iglesias, Alberto M.; Jimenez Rebagliati, Raul; Raffo Calderon, Maria C.; Manzi, Ricardo

    2000-01-01

    Steam generators water treatment with volatile amines in place of ammonia is usual today. This option seems an acceptable alternative to the generalize use of ammonia-sodium phosphate and has advantages when copper alloys are present. There are several amines that can work as corrosion inhibitor but the most useful for plant applications are: morpholine, ethanolamine and cyclohexylamine. In this work, are present the obtained results of corrosion rates measurements by electrochemical methods. The hydrothermal conditions of our experiences were similar to that of the Atucha I nuclear power plant (CNA I). pH, conductivity and dissolved oxygen measures were correlated with corrosion rates of the CNA I materials as carbon steel and admiralty brass. The faradaic impedance spectroscopy techniques allows a more detailed interpretation of corrosion rates process. Morpholine and ammonia behavior can be evaluated under power plant operations conditions with the accumulated experience of CNA I. Results are present throughout material release and his effects over heat transfer parameters. (author)

  5. S-process nucleosynthesis in low mass AGB Stars: do we really need an improved determination of the 13C(α, n)16O reaction rate?

    International Nuclear Information System (INIS)

    Cristallo, S.; Straniero, O.; Gallino, R.

    2005-01-01

    Thermally pulsing Asymptotic Giant Branch stars are responsible for the nucleosynthesis of the main component of the cosmic s-elements. The most important neutron source is the 13 C(α, n) 16 O reaction. Owing to the presence of a subthreshold resonance, the low energy extrapolation is a rather complex task. The rate quoted in the literature differ up to a factor of 4 at typical stellar energies. The latest improvements in computer power allows us to calculate the evolution of TP-AGB stars coupled with a full nuclear network, extending from hydrogen to lead. Here we discuss the effects of the variation of the 13 C(α, n) 16 O rate on the predicted neutron capture nucleosynthesis

  6. High-voltage power supply of ND6 portable dose rate meter

    International Nuclear Information System (INIS)

    Wang Shaling

    2001-01-01

    Portable dose rate meter needs to be equipped with a set of high-voltage power supply which is supplied by batteries and has characteristic of high quality, low energy expense and small size. The author introduces application conditions and performance guide line

  7. Efficient high-peak-power and high-repetition-rate eye-safe laser using an intracavity KTP OPO

    International Nuclear Information System (INIS)

    Guo, J; Jiao, Z X; Wang, B; He, G Y

    2015-01-01

    An efficient high-peak-power and high-repetition-rate intracavity KTP optical parametric oscillator pumped by a Q-switched Nd:YVO 4 laser is demonstrated. We achieved 1.5 W output power of 1.5 μm at 10 kHz repetition rate with the pulse duration of 6 ns. The maximum peak power of 25 kW and the maximum pulse energy of 150 μJ have been obtained. The maximum conversion efficiency of 9.5% is achieved with respect to a laser diode power of 10.5 W. (paper)

  8. Common cause failure rate estimates for diesel generators in nuclear power plants

    International Nuclear Information System (INIS)

    Steverson, J.A.; Atwood, C.L.

    1982-01-01

    Common cause fault rates for diesel generators in nuclear power plants are estimated, using Licensee Event Reports for the years 1976 through 1978. The binomial failure rate method, used for obtaining the estimates, is briefly explained. Issues discussed include correct classification of common cause events, grouping of the events into homogeneous data subsets, and dealing with plant-to-plant variation

  9. Rate Optimization of Two-Way Relaying with Wireless Information and Power Transfer

    Directory of Open Access Journals (Sweden)

    Thinh Phu Do

    2017-11-01

    Full Text Available We consider the simultaneous wireless information and power transfer in two-phase decode-and-forward two-way relaying networks, where a relay harvests the energy from the signal to be relayed through either power splitting or time splitting. Here, we formulate the resource allocation problems optimizing the time-phase and signal splitting ratios to maximize the sum rate of the two communicating devices. The joint optimization problems are shown to be convex for both the power splitting and time splitting approaches after some transformation if required to be solvable with an existing solver. To lower the computational complexity, we also present the suboptimal methods optimizing the splitting ratio for the fixed time-phase and derive a closed-form solution for the suboptimal method based on the power splitting. The results demonstrate that the power splitting approaches outperform their time splitting counterparts and the suboptimal power splitting approach provides a performance close to the optimal one while reducing the complexity significantly.

  10. Electrification of France national economy on the base of accelerated growth of nuclear power

    International Nuclear Information System (INIS)

    Grinkevich, R.N.; Mazarovich, E.O.

    1988-01-01

    The role of nuclear power in the development of France economy is analysed. Dynamics of economy and power engineering development in 1970-2000, gross domestic product growth rates, dynamics of structure of power resource consumption for electric power production, growth rates of basic labour and industrial product indices are considered. Advance of electric power consumption as compared to primary fuel and power resource consumption is stressed. The French NPP installed capacity in 1985 made up 37.5 GW or 43% of the capacity of all the electric power stations. 390 TWxh of electric power will be produced in France in 2000 which will make up 81.3% of the total production

  11. Extended spider cognition.

    Science.gov (United States)

    Japyassú, Hilton F; Laland, Kevin N

    2017-05-01

    There is a tension between the conception of cognition as a central nervous system (CNS) process and a view of cognition as extending towards the body or the contiguous environment. The centralised conception requires large or complex nervous systems to cope with complex environments. Conversely, the extended conception involves the outsourcing of information processing to the body or environment, thus making fewer demands on the processing power of the CNS. The evolution of extended cognition should be particularly favoured among small, generalist predators such as spiders, and here, we review the literature to evaluate the fit of empirical data with these contrasting models of cognition. Spiders do not seem to be cognitively limited, displaying a large diversity of learning processes, from habituation to contextual learning, including a sense of numerosity. To tease apart the central from the extended cognition, we apply the mutual manipulability criterion, testing the existence of reciprocal causal links between the putative elements of the system. We conclude that the web threads and configurations are integral parts of the cognitive systems. The extension of cognition to the web helps to explain some puzzling features of spider behaviour and seems to promote evolvability within the group, enhancing innovation through cognitive connectivity to variable habitat features. Graded changes in relative brain size could also be explained by outsourcing information processing to environmental features. More generally, niche-constructed structures emerge as prime candidates for extending animal cognition, generating the selective pressures that help to shape the evolving cognitive system.

  12. A Method for Harmonic Sources Detection based on Harmonic Distortion Power Rate

    Science.gov (United States)

    Lin, Ruixing; Xu, Lin; Zheng, Xian

    2018-03-01

    Harmonic sources detection at the point of common coupling is an essential step for harmonic contribution determination and harmonic mitigation. The harmonic distortion power rate index is proposed for harmonic source location based on IEEE Std 1459-2010 in the paper. The method only based on harmonic distortion power is not suitable when the background harmonic is large. To solve this problem, a threshold is determined by the prior information, when the harmonic distortion power is larger than the threshold, the customer side is considered as the main harmonic source, otherwise, the utility side is. A simple model of public power system was built in MATLAB/Simulink and field test results of typical harmonic loads verified the effectiveness of proposed method.

  13. Two-way DF relaying assisted D2D communication: ergodic rate and power allocation

    Science.gov (United States)

    Ni, Yiyang; Wang, Yuxi; Jin, Shi; Wong, Kai-Kit; Zhu, Hongbo

    2017-12-01

    In this paper, we investigate the ergodic rate for a device-to-device (D2D) communication system aided by a two-way decode-and-forward (DF) relay node. We first derive closed-form expressions for the ergodic rate of the D2D link under asymmetric and symmetric cases, respectively. We subsequently discuss two special scenarios including weak interference case and high signal-to-noise ratio case. Then we derive the tight approximations for each of the considered scenarios. Assuming that each transmitter only has access to its own statistical channel state information (CSI), we further derive closed-form power allocation strategy to improve the system performance according to the analytical results of the ergodic rate. Furthermore, some insights are provided for the power allocation strategy based on the analytical results. The strategies are easy to compute and require to know only the channel statistics. Numerical results show the accuracy of the analysis results under various conditions and test the availability of the power allocation strategy.

  14. Power up your plant - An introduction to integrated process and power automation

    Energy Technology Data Exchange (ETDEWEB)

    Vasel, Jeffrey

    2010-09-15

    This paper discusses how a single integrated system can increase energy efficiency, improve plant uptime, and lower life cycle costs. Integrated Process and Power Automation is a new system integration architecture and power strategy that addresses the needs of the process and power generation industries. The architecture is based on Industrial Ethernet standards such as IEC 61850 and Profinet as well as Fieldbus technologies. The energy efficiency gains from integration are discussed in a power generation use case. A power management system success story from a major oil and gas company, Petrobras, is also discussed.

  15. Power consumption analysis of constant bit rate video transmission over 3G networks

    DEFF Research Database (Denmark)

    Ukhanova, Ann; Belyaev, Evgeny; Wang, Le

    2012-01-01

    This paper presents an analysis of the power consumption of video data transmission with constant bit rate over 3G mobile wireless networks. The work includes the description of the radio resource control transition state machine in 3G networks, followed by a detailed power consumption analysis...... and measurements of the radio link power consumption. Based on this description and analysis, we propose our power consumption model. The power model was evaluated on a smartphone Nokia N900, which follows 3GPP Release 5 and 6 supporting HSDPA/HSUPA data bearers. We also propose a method for parameter selection...... for the 3GPP transition state machine that allows to decrease power consumption on a mobile device taking signaling traffic, buffer size and latency restrictions into account. Furthermore, we discuss the gain in power consumption vs. PSNR for transmitted video and show the possibility of performing power...

  16. Energy, electricity and nuclear power estimates for the period up to 2020. July 2002 ed

    International Nuclear Information System (INIS)

    2002-01-01

    Reference Data Series No. 1 is an annual publication - currently in its twenty-second edition - containing estimates of energy, electricity and nuclear power trends up to the year 2020. Nuclear data presented in Table 1 are based on actual statistical data collected by the IAEA's Power Reactor Information System (PRIS). Energy and electricity data for 2001, however, are estimated, since the latest available information from the Department of Economic and Social Affairs of the United Nations is for 1999. Population data originate from the 'World Population Prospects' (2001 Revision), published by the Population Division of the UN Department of Economic and Social Affairs, and the 2001 values are estimates. The future growth of energy, electricity and nuclear power up to the year 2020 is presented as low and high estimates in order to encompass the uncertainties associated with the future. These estimates should be viewed as very general growth trends whose validity must constantly be subjected to critical review. The nuclear generating capacity estimates presented in Table 3 are derived from a country by country bottom-up approach. They are established by a group of experts participating each year in the IAEA's consultancy on Nuclear Capacity Projections and based upon a review of nuclear power projects and programmes in Member States. The total energy consumption has been calculated by summing the primary energy consumption and the net secondary energy import. The values shown in Table 9 refer to primary energy consumed for the generation of electricity. Owing to differences in conversion efficiencies, the percentage values are different from the shares of electricity generation presented in Tables 1 and 5

  17. An up-link power control for demand assignment International Business Satellite Communications Network

    Science.gov (United States)

    Nohara, Mitsuo; Takeuchi, Yoshio; Takahata, Fumio

    Up-link power control (UPC) is one of the essential technologies to provide efficient satellite communication systems operated at frequency bands above 10 GHz. A simple and cost-effective UPC scheme applicable to a demand assignment international business satellite communications system has been developed. This paper presents the UPC scheme, including the hardware implementation and its performance.

  18. Performance of fast reactor mixed-oxide fuels pins during extended overpower transients

    International Nuclear Information System (INIS)

    Tsai, H.; Neimark, L.A.; Asaga, T.; Shikakura, S.

    1991-02-01

    The Operational Reliability Testing (ORT) program, a collaborative effort between the US Department of Energy and the Power Reactor and Nuclear Fuel Development Corp. (PNC) of Japan, was initiated in 1982 to investigate the behavior of mixed-oxide fuel pin under various slow-ramp transient and duty-cycle conditions. In the first phase of the program, a series of four extended overpower transient tests, with severity sufficient to challenge the pin cladding integrity, was conducted. The objectives of the designated TOPI-1A through -1D tests were to establish the cladding breaching threshold and mechanisms, and investigate the thermal and mechanical effects of the transient on pin behavior. The tests were conducted in EBR-2, a normally steady-state reactor. The modes of transient operation in EBR-2 were described in a previous paper. Two ramp rates, 0.1%/s and 10%/s, were selected to provide a comparison of ramp-rate effects on fuel behavior. The test pins chosen for the series covered a range of design and pre-test irradiation parameters. In the first test (1A), all pins maintained their cladding integrity during the 0.1%/s ramp to 60% peak overpower. Fuel pins with aggressive designs, i.e., high fuel- smear density and/or thin cladding, were, therefore, included in the follow-up 1B and 1C tests to enhance the likelihood of achieving cladding breaching. In the meantime, a higher pin overpower capability, to greater than 100%, was established by increasing the reactor power limit from 62.5 to 75 MWt. In this paper, the significant results of the 1B and 1C tests are presented. 4 refs., 5 figs., 1 tab

  19. Tokamak start-up with electron-cyclotron heating

    International Nuclear Information System (INIS)

    Holly, D.J.; Prager, S.C.; Shepard, D.A.; Sprott, J.C.

    1981-01-01

    Experiments are described in which the start-up voltage in a tokamak is reduced by about a factor of two by the use of a modest amount of electron cyclotron resonance heating power for pre-ionization. The solution of the zero-dimensional start-up equations indicates that the effect is due to the high initial density which increases the rate at which the conductivity increases in the neutral-dominated initial plasma. The effect extrapolates favourably to larger tokamaks. A 50% reduction in the start-up volt-second requirement and impurity reflux is also observed. (author)

  20. Tokamak start-up with electron-cyclotron heating

    Energy Technology Data Exchange (ETDEWEB)

    Holly, D J; Prager, S C; Shepard, D A; Sprott, J C [Wisconsin Univ., Madison (USA)

    1981-11-01

    Experiments are described in which the start-up voltage in a tokamak is reduced by about a factor of two by the use of a modest amount of electron cyclotron resonance heating power for pre-ionization. The solution of the zero-dimensional start-up equations indicates that the effect is due to the high initial density which increases the rate at which the conductivity increases in the neutral-dominated initial plasma. The effect extrapolates favourably to larger tokamaks. A 50% reduction in the start-up volt-second requirement and impurity reflux is also observed.

  1. Low-frequency wideband vibration energy harvesting by using frequency up-conversion and quin-stable nonlinearity

    Science.gov (United States)

    Wang, Chen; Zhang, Qichang; Wang, Wei

    2017-07-01

    This work presents models and experiments of an impact-driven and frequency up-converted wideband piezoelectric-based vibration energy harvester with a quintuple-well potential induced by the combination effect of magnetic nonlinearity and mechanical piecewise-linearity. Analysis shows that the interwell motions during coupled vibration period enable to increase electrical power output in comparison to conventional frequency up-conversion technology. Besides, the quintuple-well potential with shallower potential wells could extend the harvester's operating bandwidth to lower frequencies. Experiments demonstrate our proposed approach can dramatically boost the measured power of the energy harvester as much as 35 times while its lower cut-off frequency is two times lower than that of a conventional counterpart. These results reveal our proposed approach shows promise for powering portable wireless smart devices from low-intensity, low-frequency vibration sources.

  2. High repetition rate intense ion beam source

    International Nuclear Information System (INIS)

    Hammer, D.A.; Glidden, S.C.; Noonan, B.

    1992-01-01

    This final report describes a ≤ 150kV, 40kA, 100ns high repetition rate pulsed power system and intense ion beam source which is now in operation at Cornell University. Operation of the Magnetically-controlled Anode Plasma (MAP) ion diode at > 100Hz (burst mode for up to 10 pulse bursts) provides an initial look at repetition rate limitations of both the ion diode and beam diagnostics. The pulsed power systems are capable of ≥ 1kHz operation (up to 10 pulse bursts), but ion diode operation was limited to ∼100Hz because of diagnostic limitations. By varying MAP diode operating parameters, ion beams can be extracted at a few 10s of keV or at up to 150keV, the corresponding accelerating gap impedance ranging from about 1Ω to about 10Ω. The ability to make hundreds of test pulses per day at an average repetition rate of about 2 pulses per minute permits statistical analysis of diode operation as a function of various parameters. Most diode components have now survived more than 10 4 pulses, and the design and construction of the various pulsed power components of the MAP diode which have enabled us to reach this point are discussed. A high speed data acquisition system and companion analysis software capable of acquiring pulse data at 1ms intervals (in bursts of up to 10 pulses) and processing it in ≤ min is described

  3. Scale-up from shake flasks to bioreactor, based on power input and Streptomyces lividans morphology, for the production of recombinant APA (45/47 kDa protein) from Mycobacterium tuberculosis.

    Science.gov (United States)

    Gamboa-Suasnavart, Ramsés A; Marín-Palacio, Luz D; Martínez-Sotelo, José A; Espitia, Clara; Servín-González, Luis; Valdez-Cruz, Norma A; Trujillo-Roldán, Mauricio A

    2013-08-01

    Culture conditions in shake flasks affect filamentous Streptomyces lividans morphology, as well the productivity and O-mannosylation of recombinant Ala-Pro-rich O-glycoprotein (known as the 45/47 kDa or APA antigen) from Mycobacterium tuberculosis. In order to scale up from previous reported shake flasks to bioreactor, data from the literature on the effect of agitation on morphology of Streptomyces strains were used to obtain gassed volumetric power input values that can be used to obtain a morphology of S. lividans in bioreactor similar to the morphology previously reported in coiled/baffled shake flasks by our group. Morphology of S. lividans was successfully scaled-up, obtaining similar mycelial sizes in both scales with diameters of 0.21 ± 0.09 mm in baffled and coiled shake flasks, and 0.15 ± 0.01 mm in the bioreactor. Moreover, the specific growth rate was successfully scaled up (0.09 ± 0.02 and 0.12 ± 0.01 h(-1), for bioreactors and flasks, respectively), and the recombinant protein productivity measured by densitometry, as well. More interestingly, the quality of the recombinant glycoprotein measured as the amount of mannoses attached to the C-terminal of APA was also scaled- up; with up to five mannose residues in cultures carried out in shake flasks; and six in the bioreactor. However, final biomass concentration was not similar, indicating that although the process can be scaled-up using the power input, others factors like oxygen transfer rate, tip speed or energy dissipation/circulation function can be an influence on bacterial metabolism.

  4. Power conditioning unit for photovoltaic power systems

    Science.gov (United States)

    Beghin, G.; Nguyen Phuoc, V. T.

    Operational features and components of a power conditioning unit for interconnecting solar cell module powers with a utility grid are outlined. The two-stage unit first modifies the voltage to desired levels on an internal dc link, then inverts the current in 2 power transformers connected to a vector summation control to neutralize harmonic distortion up to the 11th harmonic. The system operates in parallel with the grid with extra inductors to absorb line-to-line voltage and phase differences, and permits peak power use from the PV array. Reactive power is gained internally, and a power system controller monitors voltages, frequencies, and currents. A booster preregulator adjusts the input voltage from the array to provide voltage regulation for the inverter, and can commutate 450 amps. A total harmonic distortion of less than 5 percent is claimed, with a rating of 5 kVA, 50/60 Hz, 3-phase, and 4-wire.

  5. Nuclear power faces up to competition. A textbook on current controversial issues

    International Nuclear Information System (INIS)

    Goering, R.W.; Oesterwind, D.

    1995-01-01

    Nuclear power plants should face up to competition in the energy sector, and nuclear power reactor technology should at last be discussed without bias. The criteria to be applied are: environmental effects, availability, economics, safety and general acceptance. For decades now nuclear power plant operation has been proving to meet the first three of the above criteria. But although the engineered safety concepts and the available operating data proved successful and reliable, the safety philosophy underlying nuclear reactor technology still could not win general acceptance among the population. There have been considerable advances in engineered nuclear safety over the last few years. Reactors have been designed on the basis of a novel safety philosophy. Such novel concepts deserve a new approach for assessment, taking into account the worldwide population explosion, increasing energy consumption, and rising environmental hazards. The book in hand reviews and explains the advanced safety concepts, so that readers can get insight into the safety qualities of novel reactor types and thus criteria for novel assessment. (orig.) [de

  6. Estimation of Leak Rate Through Cracks in Bimaterial Pipes in Nuclear Power Plants

    Directory of Open Access Journals (Sweden)

    Jai Hak Park

    2016-10-01

    Full Text Available The accurate estimation of leak rate through cracks is crucial in applying the leak before break (LBB concept to pipeline design in nuclear power plants. Because of its importance, several programs were developed based on the several proposed flow models, and used in nuclear power industries. As the flow models were developed for a homogeneous pipe material, however, some difficulties were encountered in estimating leak rates for bimaterial pipes. In this paper, a flow model is proposed to estimate leak rate in bimaterial pipes based on the modified Henry–Fauske flow model. In the new flow model, different crack morphology parameters can be considered in two parts of a flow path. In addition, based on the proposed flow model, a program was developed to estimate leak rate for a crack with linearly varying cross-sectional area. Using the program, leak rates were calculated for through-thickness cracks with constant or linearly varying cross-sectional areas in a bimaterial pipe. The leak rate results were then compared and discussed in comparison with the results for a homogeneous pipe. The effects of the crack morphology parameters and the variation in cross-sectional area on the leak rate were examined and discussed.

  7. Wind power in China – Dream or reality?

    International Nuclear Information System (INIS)

    Li, X.; Hubacek, K.; Siu, Y.L.

    2012-01-01

    After tremendous growth of wind power generation capacity in recent years, China now has 44.7 GW of wind-derived power. Despite the recent growth rates and promises of a bright future, two important issues - the capability of the grid infrastructure and the availability of backup systems - must be critically discussed and tackled in the medium term. The study shows that only a relatively small share of investment goes towards improving and extending the electricity infrastructure which is a precondition for transmitting clean wind energy to the end users. In addition, the backup systems are either geographically too remote from the potential wind power sites or currently financially infeasible. Finally, the introduction of wind power to the coal-dominated energy production system is not problem-free. Frequent ramp ups and downs of coal-fired plants lead to lower energy efficiency and higher emissions, which are likely to negate some of the emission savings from wind power. The current power system is heavily reliant on independently acting but state-owned energy companies optimizing their part of the system, and this is partly incompatible with building a robust system supporting renewable energy technologies. Hence, strategic, top-down co-ordination and incentives to improve the overall electricity infrastructure is recommended. -- Highlights: ► We analyse the power grid availability for large-scale wind integration in China. ► We examine the choices of backup systems for the compensation of wind power. ► The Chinese power grid infrastructure is not sufficient to integrate the wind power. ► The backup systems are either geographically unavailable or financially infeasible. ► Using coal-fired plants as the backup system is unavoidable but not problem-free.

  8. Power, stability of power, and creativity

    NARCIS (Netherlands)

    Sligte, Daniel J.; de Dreu, Carsten K. W.; Nijstad, Bernard A.

    Power hierarchies are an essential aspect of social organization, create stability and social order, and provide individuals with incentives to climb the hierarchical ladder. Extending previous work on power and creativity, we put forward that this relationship critically depends on both the

  9. Power, stability of power, and creativity

    NARCIS (Netherlands)

    Sligte, D.J.; de Dreu, C.K.W.; Nijstad, B.A.

    2011-01-01

    Power hierarchies are an essential aspect of social organization, create stability and social order, and provide individuals with incentives to climb the hierarchical ladder. Extending previous work on power and creativity, we put forward that this relationship critically depends on both the

  10. Thermoelectric properties and performance of flexible reduced graphene oxide films up to 3,000 K

    Science.gov (United States)

    Li, Tian; Pickel, Andrea D.; Yao, Yonggang; Chen, Yanan; Zeng, Yuqiang; Lacey, Steven D.; Li, Yiju; Wang, Yilin; Dai, Jiaqi; Wang, Yanbin; Yang, Bao; Fuhrer, Michael S.; Marconnet, Amy; Dames, Chris; Drew, Dennis H.; Hu, Liangbing

    2018-02-01

    The development of ultrahigh-temperature thermoelectric materials could enable thermoelectric topping of combustion power cycles as well as extending the range of direct thermoelectric power generation in concentrated solar power. However, thermoelectric operation temperatures have been restricted to under 1,500 K due to the lack of suitable materials. Here, we demonstrate a thermoelectric conversion material based on high-temperature reduced graphene oxide nanosheets that can perform reliably up to 3,000 K. After a reduction treatment at 3,300 K, the nanosheet film exhibits an increased conductivity to 4,000 S cm-1 at 3,000 K and a high power factor S2σ = 54.5 µW cm-1 K-2. We report measurements characterizing the film's thermoelectric properties up to 3,000 K. The reduced graphene oxide film also exhibits a high broadband radiation absorbance and can act as both a radiative receiver and a thermoelectric generator. The printable, lightweight and flexible film is attractive for system integration and scalable manufacturing.

  11. Improvement for enhancing effectiveness of universal power system (UPS) continuous testing process

    Science.gov (United States)

    Sriratana, Lerdlekha

    2018-01-01

    This experiment aims to enhance the effectiveness of the Universal Power System (UPS) continuous testing process of the Electrical and Electronic Institute by applying work scheduling and time study methods. Initially, the standard time of testing process has not been considered that results of unaccurate testing target and also time wasting has been observed. As monitoring and reducing waste time for improving the efficiency of testing process, Yamazumi chart and job scheduling theory (North West Corner Rule) were applied to develop new work process. After the improvements, the overall efficiency of the process possibly increased from 52.8% to 65.6% or 12.7%. Moreover, the waste time could reduce from 828.3 minutes to 653.6 minutes or 21%, while testing units per batch could increase from 3 to 4 units. Therefore, the number of testing units would increase from 12 units up to 20 units per month that also contribute to increase of net income of UPS testing process by 72%.

  12. Keeping up with a warming world; assessing the rate of adaptation to climate change

    NARCIS (Netherlands)

    Visser, M.E.

    2008-01-01

    The pivotal question in the debate on the ecological effects of climate change is whether species will be able to adapt fast enough to keep up with their changing environment. If we establish the maximal rate of adaptation, this will set an upper limit to the rate at which temperatures can increase

  13. Tuberculosis incidence rates during 8 years of follow-up of an antiretroviral treatment cohort in South Africa: comparison with rates in the community.

    Directory of Open Access Journals (Sweden)

    Ankur Gupta

    Full Text Available Although antiretroviral therapy (ART is known to be associated with time-dependent reductions in tuberculosis (TB incidence, the long-term impact of ART on incidence remains imprecisely defined due to limited duration of follow-up and incomplete CD4 cell count recovery in existing studies. We determined TB incidence in a South African ART cohort with up to 8 years of follow-up and stratified rates according to CD4 cell count recovery. We compared these rates with those of HIV-uninfected individuals living in the same community.Prospectively collected clinical data on patients receiving ART in a community-based cohort in Cape Town were analysed. 1544 patients with a median follow-up of 5.0 years (IQR 2.4-5.8 were included in the analysis. 484 episodes of incident TB (73.6% culture-confirmed were diagnosed in 424 patients during 6506 person-years (PYs of follow-up. The TB incidence rate during the first year of ART was 12.4 (95% CI 10.8-14.4 cases/100PYs and decreased to 4.92 (95% CI 3.64-8.62 cases/100PYs between 5 and 8 years of ART. During person-time accrued within CD4 cell strata 0-100, 101-200, 201-300, 301-400, 401-500, 501-700 and ≥700 cells/µL, TB incidence rates (95% CI were 25.5 (21.6-30.3, 11.2 (9.4-13.5, 7.9 (6.4-9.7, 5.0 (3.9-6.6, 5.1 (3.8-6.8, 4.1 (3.1-5.4 and 2.7 (1.7-4.5 cases/100PYs, respectively. Overall, 75% (95% CI 70.9-78.8 of TB episodes were recurrent cases. Updated CD4 cell count and viral load measurements were independently associated with long-term TB risk. TB rates during person-time accrued in the highest CD4 cell count stratum (>700 cells/µL were 4.4-fold higher that the rate in HIV uninfected individuals living in the same community (2.7 versus 0.62 cases/100PYs; 95%CI 0.58-0.65.TB rates during long-term ART remained substantially greater than rates in the local HIV uninfected populations regardless of duration of ART or attainment of CD4 cell counts exceeding 700 cells/µL.

  14. Scale-up of a mixer-settler extractor using a unit operations approach

    International Nuclear Information System (INIS)

    Lindholm, D.C.; Bautista, R.G.

    1976-01-01

    The results of scale-up studies on a continuous, multistage horizontal mixer-settler extractor are presented. The chemical and mechanical system involves the separation of lanthanum from a mixture of rare earth chlorides using di(2-ethylhexyl) phosphoric acid as the solvent and dilute HCl as a scrub solution in a bench scale extractor. Each stage has a hold-up of 2.6 l. A single stage unit is utilized for scale-up studies. Results are obtained on four sizes of geometrically similar units, the largest being six times the volume of the original bench size. A unit operations technique is chosen so that mixing and settling can be examined independently. Variables examined include type of continuous phase, flow rate of inlet streams, and power input to the mixer. Inlet flow-rate ratios are kept constant for all tests. Two potential methods of unbaffled pump-mixer scale-up are explored; the maintenance of constant impeller tip speed and constant power input. For the settler, the previously successful method of basing design on constant flow-rate per unit cross-sectional area is used

  15. False-vacuum decay in generalized extended inflation

    International Nuclear Information System (INIS)

    Holman, R.; Wang Yun; Kolb, E.W.; Chicago Univ., IL; Chicago Univ., IL; Vadas, S.L.

    1990-01-01

    We study false-vacuum decay in the context of generalized extended inflationary theories, and compute the bubble nucleation rates for these theories in the limit of G N →0. We find that the time dependence of the nucleation rate can be exponentially strong through the time dependence of the Jordan-Brans-Dicke field. This can have a pronounced effect on whether extended inflation can be succesfully implemented. (orig.)

  16. Extended radio emission and the nature of blazars

    International Nuclear Information System (INIS)

    Antonucci, R.R.J.; Ulvestad, J.S.

    1985-01-01

    The VLA has been used at 20 cm to map all 23 of the 54 confirmed blazars listed in the Angel and Stockman review paper that had not been mapped before at high resolution. (Blazars include BL Lac objects and optically violently variable quasars.) In addition, data on most of the previously mapped blazars have been reprocessed in order to achieve higher dynamic range. Extended emission has been detected associated with 49 of the 54 objects. The extended radio emission has been used to test the hypothesis that blazars are normal radio galaxies and radio quasars viewed along the jet axes. We find that blazars have substantial extended power, consistent with this hypothesis. Many have extended powers as high as the luminous Fanaroff-Riley class 2 radio doubles. The projected linear sizes are small, as expected from foreshortening of the extended sources, and many blazars have the expected core-halo morphology. There are also several small doubles, a head-tail source, and some one-sided sources, and these could be in cases where the line of sight is slightly off the jet axis, or projections of asymmetrical radio galaxies and quasars. The ratio of core to extended radio emission has been studied as a possible indicator of viewing aspect or beaming intensity. It is found to correlate with optical polarization, optical and radio core variability, and one-sided radio morphology. We can go beyond these consistency checks and work toward a proof of the hypothesis under discussion. The flux from the extended emission alone is sufficient in some blazars to qualify them for inclusion in the 3C and 4C catalogs. Suppose that the radio core emission is anisotropic, but the extended emission is predominantly isotropic. The isotropy of the extended emission implies that these blazars would be in the catalogs even if viewed from the side

  17. Power Outages

    Science.gov (United States)

    ... Publications Emergency Alerts Preparedness Portal Preparedness Messaging Calendar Social Media Preparedness Toolkits Preparedness News Languages About Us Build a Kit Close Search Enter Search Term(s): Main Content Home Be Informed Power Outages Power Outages Extended power outages may impact ...

  18. Dual Cage High Power Induction Motor with Direct Start-up. Design and FEM Analysis

    Directory of Open Access Journals (Sweden)

    LIVADARU, L.

    2013-05-01

    Full Text Available This paper presents an investigation on the design of high-power induction motor with special constraints. Direct online start-up and pull-up torque of rather high value represent two of the imposed requirements. Three different structures are analyzed, which involve deep bars, magnetic wedges and double cage respectively. The proposed solution advances a new rotor structure with two different rotor cages. The first cage acts mainly during start-up and is made of iron with both electric and magnetic properties. The second one is made of copper and represents the main rotor winding. It has a particular cross-section of the bars in order to carry into effect the required constraints both during start-up and steady-state. The proposed models are finally evaluated by means of finite element method analysis.

  19. PV Power-Generation System with a Phase-Shift PWM Technique for High Step-Up Voltage Applications

    Directory of Open Access Journals (Sweden)

    Cheng-Tao Tsai

    2012-01-01

    Full Text Available A PV power-generation system with a phase-shift pulse-width modulation (PWM technique for high step-up voltage applications is proposed. The proposed power-generation system consists of two stages. In the input stage, all power switches of the full-bridge converter with phase-shift technique can be operated with zero-current switching (ZCS at turn-on or turn-off transition. Hence, the switching losses of the power switches can be reduced. Then, in the DC output stage, a voltage-doubler circuit is used to boost a high dc-link bus voltage. To supply a utility power, a dc/ac inverter is connected to induce a sinusoidal source. In order to draw a maximum power from PV arrays source, a microcontroller is incorporated with the perturbation and observation method to implement maximum power point tracking (MPPT algorithm and power regulating scheme. In this study, a full load power of 300 W prototype has been built. Experimental results are presented to verify the performance and feasibility of the proposed PV power-generation system.

  20. An extra power saving scheme for prolonging lifetime of mobile handset in the 4G mobile networks.

    Science.gov (United States)

    Chen, Jenhui; Tarn, Woei-Hwa; Lee, Jiann-Der

    2014-01-01

    In the fourth generation or next generation networks, services of non-real-time variable bit rate (NRT-VBR) and best effort (BE) will dominate over 85% of the total traffic in the networks. In this paper, we study the power saving mechanism of NRT-VBR and BE services for mobile handsets (MHs) to prolong their battery lifetime (i.e., the sustained operation duration) in the fourth generation networks. Because the priority of NRT-VBR and BE is lower than that of real-time VBR (RT-VBR) or guaranteed bit rate (GBR) services, we investigate an extended sleep mode for lower priority services (e.g., NRT-VBR and BE) in an MH to conserve the energy. The extended sleep mode is used when the MH wakes up from the sleep mode but it cannot obtain the bandwidth from base station (BS). The proposed mechanism, named extra power saving scheme (EPSS), uses the M/M/k/k Markovian queuing model to estimate the extended sleep duration to let MHs conserve their battery energy when the networks traffic is congested. To study the performance of EPSS, an accurate analysis model of energy is presented and validated by taking a series of simulations. Numerical experiments show that EPSS can achieve 43% extra energy conservation at most when downlink resource is saturated. We conclude that the energy of MHs can be conserved further by applying EPSS when the traffic load is saturated. The effect of energy saving becomes more obvious when the portion of NRT-VBR and BE services is greater than that of RT-VBR and GBR services.

  1. Design and operation of 140 GHz gyrotron oscillators for power levels up to 1 MW CW

    Energy Technology Data Exchange (ETDEWEB)

    Jory, H.; Bier, R.; Craig, L.J.; Felch, K.; Ives, L.; Lopez, N.; Spang, S.

    1986-12-01

    Varian has designed and tested 140 GHz gyrotron oscillators that have generated output powers of 100 kW CW and 200 kW for 1 ms pulses. Upcoming tubes will be designed to operate at power levels of 200 kW CW and ultimately up to 1 MW CW. The important design considerations which are addressed in the higher power tubes include the design of the electron gun, interaction circuit, and output window. These issues will be discussed and the results of the earlier 140 GHz gyrotron work at Varian will be summarized.

  2. Design and operation of 140 GHz gyrotron oscillators for power levels up to 1 MW CW

    International Nuclear Information System (INIS)

    Jory, H.; Bier, R.; Craig, L.J.; Felch, K.; Ives, L.; Lopez, N.; Spang, S.

    1986-12-01

    Varian has designed and tested 140 GHz gyrotron oscillators that have generated output powers of 100 kW CW and 200 kW for 1 ms pulses. Upcoming tubes will be designed to operate at power levels of 200 kW CW and ultimately up to 1 MW CW. The important design considerations which are addressed in the higher power tubes include the design of the electron gun, interaction circuit, and output window. These issues will be discussed and the results of the earlier 140 GHz gyrotron work at Varian will be summarized

  3. Robust Image Regression Based on the Extended Matrix Variate Power Exponential Distribution of Dependent Noise.

    Science.gov (United States)

    Luo, Lei; Yang, Jian; Qian, Jianjun; Tai, Ying; Lu, Gui-Fu

    2017-09-01

    Dealing with partial occlusion or illumination is one of the most challenging problems in image representation and classification. In this problem, the characterization of the representation error plays a crucial role. In most current approaches, the error matrix needs to be stretched into a vector and each element is assumed to be independently corrupted. This ignores the dependence between the elements of error. In this paper, it is assumed that the error image caused by partial occlusion or illumination changes is a random matrix variate and follows the extended matrix variate power exponential distribution. This has the heavy tailed regions and can be used to describe a matrix pattern of l×m dimensional observations that are not independent. This paper reveals the essence of the proposed distribution: it actually alleviates the correlations between pixels in an error matrix E and makes E approximately Gaussian. On the basis of this distribution, we derive a Schatten p -norm-based matrix regression model with L q regularization. Alternating direction method of multipliers is applied to solve this model. To get a closed-form solution in each step of the algorithm, two singular value function thresholding operators are introduced. In addition, the extended Schatten p -norm is utilized to characterize the distance between the test samples and classes in the design of the classifier. Extensive experimental results for image reconstruction and classification with structural noise demonstrate that the proposed algorithm works much more robustly than some existing regression-based methods.

  4. Evidence of circadian and extended shift effects on reactor transient frequency

    International Nuclear Information System (INIS)

    Maloney, S.

    1992-01-01

    An extensive body of knowledge exists documenting the significant swings in error rates, perception, judgment, and overall alertness levels in the course of a day. The literature also demonstrates pronounced differences in performance levels whereby night workers routinely underperform day workers in any set of tasks. The performance split widens with task complexity. Rotating shift workers, such as nuclear power plant operators, have been shown to experience performance problems comparable to straight night workers. Finally, sleep research also documents that extended hours, such as the so-called 4-day work week, can undermine alertness levels, particularly in the last 2 to 3 h of a daily shift. These issues suggest that cyclical performance by shift workers may be evident in nuclear plant operators. This paper seeks evidence of such cyclical performance by examining operating transients at nuclear power plants involving human error

  5. Power/knowledge and natural resource management: Foucaultian foundations in the analysis of adaptive governance

    NARCIS (Netherlands)

    Van Assche, Kristof; Beunen, R.; Duineveld, Martijn; Gruezmacher, Monica

    2017-01-01

    In this paper, we present a conceptual framework extending Foucaultian insights on the relations between power and knowledge to link up with current insights into studies of natural resource management (NRM) and more broadly environmental studies. We classify discourses in NRM according to

  6. 75 FR 76727 - Evergreen Wind Power III, LLC; Supplemental Notice that Initial Market-Based Rate Filing Includes...

    Science.gov (United States)

    2010-12-09

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. ER11-2201-000] Evergreen Wind Power III, LLC; Supplemental Notice that Initial Market-Based Rate Filing Includes Request for... proceeding of Evergreen Wind Power III, LLC's application for market-based rate authority, with an...

  7. Resonant laser power build-up in ALPS. A 'light-shining-through-walls' experiment

    International Nuclear Information System (INIS)

    Ehret, Klaus; Ghazaryan, Samvel; Frede, Maik

    2009-05-01

    The ALPS collaboration runs a light-shining-through-walls (LSW) experiment to search for photon oscillations into weakly interacting sub-eV particles (WISPs) inside of a superconducting HERA dipole magnet at the site of DESY. In this paper we report on the first successful integration of a large-scale optical cavity to boost the available power for WISP production in this type of experiments. The key elements are a frequency tunable narrow line-width continuous wave laser acting as the primary light source and an electronic feed-back control loop to stabilize the power build-up. We describe and characterize our apparatus and demonstrate the data analysis procedures on the basis of a brief exemplary run. (orig.)

  8. An extended range neutron rem counter

    International Nuclear Information System (INIS)

    Birattari, C.; Nuccetelli, C.; Pelliccioni, M.; Silari, M.

    1990-01-01

    Extensive Monte Carlo calculations have been carried out to assess the possibility of extending the sensitivity of a neutron rem counter of the Andersson-Braun type up to several hundred MeV. The validity of the model adopted has first been checked by comparing with experimental data the calculated response curve and the angular dependence of the sensitivity for a well known commercial rem counter. Next, a number of modifications to the configuration of the moderator-attenuator have been investigated. The response functions and angular distributions produced by two simple solutions yielding an instrument with a sensitivity extended up to 400 MeV are presented. The response of the original rem counter and of its two modified versions to nine test spectra has also been calculated. The resulting instrument is transportable rather than portable, but the availability of an extended range neutron survey meter would be of great advantage at medium and high energy particle accelerator facilities. (orig.)

  9. A portable backup power supply to assure extended decay heat removal during natural phenomena-induced station blackout

    International Nuclear Information System (INIS)

    Proctor, L.D.; Merryman, L.D.; Sallee, W.E.

    1989-01-01

    The High Flux Isotope Reactor (HFIR) is a light water cooled and moderated flux-trap type research reactor located at Oak Ridge National Laboratory (ORNL). Coolant circulation following reactor shutdown is provided by the primary coolant pumps. DC-powered pony motors drive these pumps at a reduced flow rate following shutdown of the normal ac-powered motors. Forced circulation decay heat removal is required for several hours to preclude core damage following shutdown. Recent analyses identified a potential vulnerability due to a natural phenomena-induced station blackout. Neither the offsire power supply nor the onsite emergency diesel generators are designed to withstand the effects of seismic events or tornadoes. It could not be assured that the capacity of the dedicated batteries provided as a backup power supply for the primary coolant pump pony motors is adequate to provide forced circulation cooling for the required time following such events. A portable backup power supply added to the plant to address this potential vulnerability is described

  10. LWR high burn-up operation and MOX introduction. Fuel cycle performance from the viewpoint of waste management

    International Nuclear Information System (INIS)

    Inagaki, Yaohiro; Iwasaki, Tomohiko; Niibori, Yuichi; Sato, Seichi; Ohe, Toshiaki; Kato, Kazuyuki; Torikai, Seishi; Nagasaki, Shinya; Kitayama, Kazumi

    2009-01-01

    From the viewpoint of waste management, a quantitative evaluation of LWR nuclear fuel cycle system performance was carried out, considering both higher burn-up operation of UO 2 fuel coupled with the introduction of MOX fuel. A major parameter to quantify this performance is the number of high-level waste (HLW) glass units generated per GWd (gigawatt-day based on reactor thermal power generation before electrical conversion). This parameter was evaluated for each system up to a maximum burn-up of 70GWd/THM (gigawatt-day per ton of heavy metal) assuming current conventional reprocessing and vitrification conditions where the waste loading of glass is restricted by the heat generation rate, the MoO 3 content, or the noble metal content. The results showed that higher burn-up operation has no significant influence on the number of glass units generated per GWd for UO 2 fuel, though the number of glass units per THM increases linearly with burn-up and is restricted by the heat generation rate. On the other hand, the introduction of MOX fuel causes the number of glass units per GWd to double owing to the increase in the heat generation rate. An extended cooling period of the spent fuel prior to reprocessing effectively reduces the heat generation rate for UO 2 fuel, while a separation of minor actinides (Np, Am, and Cm) from the high-level waste provides additional reduction for MOX fuel. However, neither of these leads to a substantial reduction in the number of glass units, since the MoO 3 content or the noble metal content restricts the number of glass units rather than the heat generation rate. These results suggest that both the MoO 3 content and the noble metal content provide the key to reducing the amount of waste glass that is generated, leading to an overall improvement in fuel cycle system performance. (author)

  11. Ultracapacitor-Based Uninterrupted Power Supply System

    Science.gov (United States)

    Eichenberg, Dennis J.

    2011-01-01

    The ultracapacitor-based uninterrupted power supply (UPS) system enhances system reliability; reduces life-of-system, maintenance, and downtime costs; and greatly reduces environmental impact when compared to conventional UPS energy storage systems. This design provides power when required and absorbs power when required to smooth the system load and also has excellent low-temperature performance. The UPS used during hardware tests at Glenn is an efficient, compact, maintenance-free, rack-mount, pure sine-wave inverter unit. The UPS provides a continuous output power up to 1,700 W with a surge rating of 1,870 W for up to one minute at a nominal output voltage of 115 VAC. The ultracapacitor energy storage system tested in conjunction with the UPS is rated at 5.8 F. This is a bank of ten symmetric ultracapacitor modules. Each module is actively balanced using a linear voltage balancing technique in which the cell-to-cell leakage is dependent upon the imbalance of the individual cells. The ultracapacitors are charged by a DC power supply, which can provide up to 300 VDC at 4 A. A constant-voltage, constant-current power supply was selected for this application. The long life of ultracapacitors greatly enhances system reliability, which is significant in critical applications such as medical power systems and space power systems. The energy storage system can usually last longer than the application, given its 20-year life span. This means that the ultracapacitors will probably never need to be replaced and disposed of, whereas batteries require frequent replacement and disposal. The charge-discharge efficiency of rechargeable batteries is approximately 50 percent, and after some hundreds of charges and discharges, they must be replaced. The charge-discharge efficiency of ultracapacitors exceeds 90 percent, and can accept more than a million charges and discharges. Thus, there is a significant energy savings through the efficiency improvement, and there is far less

  12. Inner conflict between nuclear power generation and electricity rates: A Japanese case study

    International Nuclear Information System (INIS)

    Ida, Takanori; Takemura, Kosuke; Sato, Masayuki

    2015-01-01

    Since the March 11 earthquake, Japanese households have been facing a trade-off problem between decreasing dependency on nuclear power generation and avoiding an increase in electricity rates. We analyze this inner conflict quantitatively, adopting two economic–psychological approaches: First, we note that the trade-off causes cognitive dissonance after making a choice that results in a wider desirability gap between the chosen and rejected alternatives. Second, the consumer surplus improves by 11.2% with a no-choice option for suspending judgment in the presence of cognitive dissonance. Third, individual characteristics such as gender and annual household income are significantly correlated with both cognitive dissonance and a preference for the no-choice option. - Highlights: • The Fukushima crisis shocked Japanese citizens' attitudes on nuclear power plants. • Citizens' attitudes toward nuclear power generation and electricity rates surveyed • The trade-off caused cognitive dissonance resulting in a hardline stance. • The consumer surplus improves with a no-choice option for suspending judgment

  13. Energy Storage Requirements for PV Power Ramp Rate Control in Northern Europe

    Directory of Open Access Journals (Sweden)

    Julius Schnabel

    2016-01-01

    Full Text Available Photovoltaic (PV generators suffer from fluctuating output power due to the highly fluctuating primary energy source. With significant PV penetration, these fluctuations can lead to power system instability and power quality problems. The use of energy storage systems as fluctuation compensators has been proposed as means to mitigate these problems. In this paper, the behavior of PV power fluctuations in Northern European climatic conditions and requirements for sizing the energy storage systems to compensate them have been investigated and compared to similar studies done in Southern European climate. These investigations have been performed through simulations that utilize measurements from the Tampere University of Technology solar PV power station research plant in Finland. An enhanced energy storage charging control strategy has been developed and tested. Energy storage capacity, power, and cycling requirements have been derived for different PV generator sizes and power ramp rate requirements. The developed control strategy leads to lesser performance requirements for the energy storage systems compared to the methods presented earlier. Further, some differences on the operation of PV generators in Northern and Southern European climates have been detected.

  14. Integrated modeling for the cyclic behavior of high power Li-ion batteries under extended operating conditions

    International Nuclear Information System (INIS)

    Miranda, Á.G.; Hong, C.W.

    2013-01-01

    Highlights: • Redefine the traditional concepts of state of charge modeling. • Accurate non-intrusive extraction method of an integrated battery model. • Indexes of performance can be employed to compare different types of batteries. • High power electrical battery model dependent on current and temperature effects. - Abstract: The dynamic thermal and electrical behavior of high power LiFePO 4 cathode-type Li-ion batteries is studied with extended considerations such as demanded current ranging from 12 to 30 A, battery temperatures ranging from 283 to 313 K and a redefinition of the concept of state of charge during cycling conditions. The equivalent electrical model, consisting of a series resistance, a parallel resistance–capacitor, a voltage source and state of charge calculators, can be improved with the addition of current and temperature gains for each element. In addition, a non-intrusively-obtained alternative thermal model extraction is proposed to uncouple from the experimental battery temperature based on electrochemical research found in the literature. This improved model extraction for high power cylindrical batteries can achieve a temperature and voltage relative runtime error in the range of 1% and 5% in average, respectively. The effects of lithium concentration in the anode and cathode are accurately predicted with state of charge accelerators, which vary linearly with temperature. Aiming for a power systems environment, the integrated battery model is built and validated experimentally to demonstrate its accurate prediction. This improved integrated battery model can be employed for battery stack simulations, improved state of charge algorithm testing and optimization of hybrid systems - with a light computational demand. Finally, a performance index radar plot is proposed to conveniently compare electrical and thermal properties of different types of batteries

  15. Energy, electricity and nuclear power estimates for the period up to 2020. July 2001 ed

    International Nuclear Information System (INIS)

    2001-01-01

    projections made by other international organizations. The nuclear generating capacity estimates presented 3 are derived from a country by country bottom-up approach. They are established by a group of experts participating each year in the IAEA's consultancy on Nuclear Capacity Projections and based upon a review of nuclear power projects and programmes in Member States. The low and high estimates reflect contrasting but not extreme underlying assumptions on the different driving factors that have an impact on nuclear power deployment. These factors, and the ways they might evolve, vary from country to country. The estimates presented provide a plausible range of nuclear capacity growth by region and worldwide. They are not intended to be predictive nor to reflect the whole range of possible futures from the lowest to the highest feasible. In the low estimates, the present barriers to nuclear power development are assumed to prevail in most countries during the coming two decades: Low economic and electricity demand growth rates in OECD countries; Public opposition to nuclear power, leading to policy decisions not to consider the nuclear option in spite of its competitive costs and potential contribution to reducing environmental impacts from electricity generation; Institutional and financing issues preventing the implementation of previously planned nuclear programmes, in particular in countries in transition and in developing countries; Inadequate mechanisms for nuclear technology transfer and nuclear project funding in developing countries. The high estimates reflect a moderate revival of nuclear power development that could result in particular from a more comprehensive comparative assessment of the different options for electricity generation, integrating economic, social, health and environmental aspects. They are based upon a review of national nuclear power programmes, assessing their technical and economic feasibility. They assume that some policy measures would be

  16. PURCHASING POWER PARITY INFLUENCE ON REAL EXCHANGE RATE BEHAVIOR IN ROMANIA

    Directory of Open Access Journals (Sweden)

    Nicolae Ghiba

    2011-12-01

    Full Text Available Purchasing Power Parity (PPP represents a fundamental concept in exchange rate modeling. The main idea is given by equality between prices in two different countries when expressing in the same currency.This paper aims to analyze the behavior of real exchange rate between EURO and Romanian new leu (RON under PPP paradigm. We use the Augmented Dickey-Fuller and Phillips-Perron stationarity tests in order to check real exchange deviations from PPP. Also, we investigate the existence of a connection between long-term between nominal exchange rate and industrial producer price indices from Romania and euro area. The main conclusions of this research highlight that PPP doesn’t holds; real exchange rate stationarity tests doest not confirm the stationarity, thus between the aforementioned three variables it doesn’t exists any equilibrium relation.

  17. Correlation of the Rates of Solvolyses of 4-Methylthiophene-2-carbonyl Chloride Using the Extended Grunwald-Winstein Equation

    International Nuclear Information System (INIS)

    Choi, Ho June; Koo, In Sun

    2012-01-01

    The specific rates of sovolysis of 4-methylthiophene-2-carbonyl chloride (1) have been determined in 26 pure and binary solvents at 25.0 .deg. C. Product selectivities are reported for solvolyses of 1 in aqueous ethanol and methanol binary mixtures. Comparison of the specific rates of solvolyses of 1 with those for p-methoxybenzoyl chloride (2) in terms of linear free energy relationships (LFER) are helpful in mechanistic considerations, as is also treatment in terms of the extended Grunwald-Winstein equation. It is proposed that the solvolyses of 1 in binary aqueous solvent mixtures proceed through an S N 1 and/or ionization (I) pathway rather than through an associative S N 2 and/or addition-elimination (A-E) pathway

  18. An Alternative Approach to the Extended Drude Model

    Science.gov (United States)

    Gantzler, N. J.; Dordevic, S. V.

    2018-05-01

    The original Drude model, proposed over a hundred years ago, is still used today for the analysis of optical properties of solids. Within this model, both the plasma frequency and quasiparticle scattering rate are constant, which makes the model rather inflexible. In order to circumvent this problem, the so-called extended Drude model was proposed, which allowed for the frequency dependence of both the quasiparticle scattering rate and the effective mass. In this work we will explore an alternative approach to the extended Drude model. Here, one also assumes that the quasiparticle scattering rate is frequency dependent; however, instead of the effective mass, the plasma frequency becomes frequency-dependent. This alternative model is applied to the high Tc superconductor Bi2Sr2CaCu2O8+δ (Bi2212) with Tc = 92 K, and the results are compared and contrasted with the ones obtained from the conventional extended Drude model. The results point to several advantages of this alternative approach to the extended Drude model.

  19. A study of thermal-hydraulic requirements for increasing the power rates for natural-circulation boiling water reactors

    International Nuclear Information System (INIS)

    Yasuo, A.; Inada, F.; Hidaka, M.

    1992-01-01

    In this paper, the feasibility of higher power rates for natural-circulation boiling water reactors (BWRs) is studied with the objective of examining the flexibility of the plant power rate in constructing such plants to cope with the increasing demand for electricity. By applying existing one-dimensional design codes, the riser heights necessary to meet two major thermal-hydraulic requirements, i.e., critical power and core stability, are systematically calculated. Several restrictions on the maximum diameter and height of the pressure vessel are also considered because these restrictions could make construction impossible or drastically increase the construction costs. A very simple map of the dominant parameters for higher power rates is obtained. It is concluded that natural-circulation BWRs of >1000 MW (electric) will be feasible within the restrictions considered here

  20. Retrospective Dosimetry and Clinical Follow-up Programme of Chernobyl Accident Clean-up Workers in Latvia

    International Nuclear Information System (INIS)

    Mironova-Ulmane, N.; Pavlenko, A.; Zvagule, T.; Karner, T.; Bruvere, R.; Volrate, A.

    2001-01-01

    Full text: About 6500 Latvian inhabitants were recruited for clean-up works at Chernobyl Nuclear Power Plant during 1986-1991. Absorbed doses for them are usually unknown, because only less then half of the clean-up workers cohort had officially documented external exposure. Clinical investigations show high morbidity rate of clean-up workers compared with general population. The results of Electronic Spin Resonance (ESR) dose reconstruction (doses absorbed in the tooth enamel) for the clean-up workers were always higher as documented of exposure doses of physical measurements. In many cases more than half of total absorbed dose is due to 90 Sr accumulated in teeth. Most of the clean-up workers have poli-symptomatic sicknesses that exhibit tendency to progress, and their morbidity exceeds that observed in general population. ESR dosimetry programs and clinical follow-up improved existing knowledge in the field of radiation medicine. These data will help to develop and apply the proper treatment and rehabilitation procedures for clean-up workers. (author)