WorldWideScience

Sample records for expandable prosthetic titanium

  1. Custom-made laser-welded titanium implant prosthetic abutment.

    Science.gov (United States)

    Iglesia-Puig, Miguel A

    2005-10-01

    A technique to create an individually modified implant prosthetic abutment is described. An overcasting is waxed onto a machined titanium abutment, cast in titanium, and joined to it with laser welding. With the proposed technique, a custom-made titanium implant prosthetic abutment is created with adequate volume and contour of metal to support a screw-retained, metal-ceramic implant-supported crown.

  2. Fusionless instrumentation systems for congenital scoliosis: expandable spinal rods and vertical expandable prosthetic titanium rib in the management of congenital spine deformities in the growing child.

    Science.gov (United States)

    Yazici, Muharrem; Emans, John

    2009-08-01

    Review of relevant literature including personal opinions. To review the current researches investigating the efficacy of growing rod and thoracic expansion techniques in the treatment of congenital spine deformity of young children, and to highlight the contrasting advantages and limitations in the fusionless treatment of progressive congenital scoliosis. Congenital scoliosis has the potential for severe spinal deformity and thoracic insufficiency syndrome (TIS). Conventional fusion treatments in children tend to shorten the spine further exacerbating trunk shortening and TIS. In the surgical treatment of congenital spinal deformities in young children, while reconstructing the spinal deformity, one should simultaneously pursue preserving the growth potential of the vertebrae, improving the volume, symmetry, and functions of the thorax, and protecting this improvement during the growth. Today, employed in the treatment of spinal deformities of young children, there are 2 deformity reconstruction methods serving these targets: Growing rod technique and vertical expandable prosthetic titanium rib (VEPTR) with or without expansion thoracostomy. Peer-reviewed research articles and major international meeting presentations were reviewed. Methods were compared in terms of advantages and limitations. The growing rod technique is a safe and reliable method in the treatment of congenital spine deformity of young children who present some flexibility in the anomalous segment, or when the congenital anomaly involves a vertebral segment too long for resection, or with compensating curve with structural pattern concomitant to the congenital deformity. Expansion thoracostomy and VEPTR are the appropriate choice for severe congenital spine deformity when a large amount of growth remains. Although ventilator dependence is significantly decreasing, thoracic volume and space available for the lung are increased after expansion thoracostomy and VEPTR. Growing rod technique should be

  3. Prosthetics / Limb Loss

    Science.gov (United States)

    ... implant to encourage the sealing process. Implanting titanium prosthetic components avoids the need for a socket. But preventing bacterial invasion and infection is a key challenge, one that this research ...

  4. Microstructural and micromechanical tests of titanium biomaterials intended for prosthetic reconstructions.

    Science.gov (United States)

    Ryniewicz, Anna M; Bojko, Łukasz; Ryniewicz, Wojciech I

    2016-01-01

    The aim of the present paper was a question of structural identification and evaluation of strength parameters of Titanium (Ticp - grade 2) and its alloy (Ti6Al4V) which are used to serve as a base for those permanent prosthetic supplements which are later manufactured employing CAD/CAM systems. Microstructural tests of Ticp and Ti6Al4V were conducted using an optical microscope as well as a scanning microscope. Hardness was measured with the Vickers method. Micromechanical properties of samples: microhardness and Young's modulus value, were measured with the Oliver and Pharr method. Based on studies using optical microscopy it was observed that the Ticp from the milling technology had a single phase, granular microstructure. The Ti64 alloy had a two-phase, fine-grained microstructure with an acicular-lamellar character. The results of scanning tests show that titanium Ticp had a single phase structure. On its grain there was visible acicular martensite. The structure of the two phase Ti64 alloy consists of a β matrix as well as released α phase deposits in the shape of extended needles. Micromechanical tests demonstrated that the alloy of Ti64 in both methods showed twice as high the microhardness as Ticp. In studies of Young's modulus of Ti64 alloy DMLS technology have lower value than titanium milling technology. According to the results obtained, the following conclusion has been drawn: when strength aspect is discussed, the DMLS method is a preferred one in manufacturing load structures in dentistry and may be an alternate way for the CAD/CAM system used in decrement processing.

  5. Reverse engineering of mandible and prosthetic framework: Effect of titanium implants in conjunction with titanium milled full arch bridge prostheses on the biomechanics of the mandible.

    Science.gov (United States)

    De Santis, Roberto; Gloria, Antonio; Russo, Teresa; D'Amora, Ugo; Varriale, Angelo; Veltri, Mario; Balleri, Piero; Mollica, Francesco; Riccitiello, Francesco; Ambrosio, Luigi

    2014-12-18

    This study aimed at investigating the effects of titanium implants and different configurations of full-arch prostheses on the biomechanics of edentulous mandibles. Reverse engineered, composite, anisotropic, edentulous mandibles made of a poly(methylmethacrylate) core and a glass fibre reinforced outer shell were rapid prototyped and instrumented with strain gauges. Brånemark implants RP platforms in conjunction with titanium Procera one-piece or two-piece bridges were used to simulate oral rehabilitations. A lateral load through the gonion regions was used to test the biomechanical effects of the rehabilitations. In addition, strains due to misfit of the one-piece titanium bridge were compared to those produced by one-piece cast gold bridges. Milled titanium bridges had a better fit than cast gold bridges. The stress distribution in mandibular bone rehabilitated with a one-piece bridge was more perturbed than that observed with a two-piece bridge. In particular the former induced a stress concentration and stress shielding in the molar and symphysis regions, while for the latter design these stresses were strongly reduced. In conclusion, prosthetic frameworks changed the biomechanics of the mandible as a result of both their design and manufacturing technology. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Influence of surgical and prosthetic techniques on marginal bone loss around titanium implants. Part I: immediate loading in fresh extraction sockets.

    Science.gov (United States)

    Berberi, Antoine N; Tehini, Georges E; Noujeim, Ziad F; Khairallah, Alexandre A; Abousehlib, Moustafa N; Salameh, Ziad A

    2014-10-01

    Delayed placement of implant abutments has been associated with peri-implant marginal bone loss; however, long-term results obtained by modifying surgical and prosthetic techniques after implant placement are still lacking. This study aimed to evaluate the marginal bone loss around titanium implants placed in fresh extraction sockets using two loading protocols after a 5-year follow-up period. A total of 36 patients received 40 titanium implants (Astra Tech) intended for single-tooth replacement. Implants were immediately placed into fresh extraction sockets using either a one-stage (immediate loading by placing an interim prosthesis into functional occlusion) or a two-stage prosthetic loading protocol (insertion of abutments after 8 weeks of healing time). Marginal bone levels relative to the implant reference point were evaluated at four time intervals using intraoral radiographs: at time of implant placement, and 1, 3, and 5 years after implant placement. Measurements were obtained from mesial and distal surfaces of each implant (α = 0.05). One-stage immediate implant placement into fresh extraction sockets resulted in a significant reduction in marginal bone loss (p sockets reduced marginal bone loss and did not compromise the success rate of the restorations. © 2014 by the American College of Prosthodontists.

  7. Direct metal laser sintering (DMLS) of a customized titanium mesh for prosthetically guided bone regeneration of atrophic maxillary arches.

    Science.gov (United States)

    Ciocca, L; Fantini, M; De Crescenzio, F; Corinaldesi, G; Scotti, R

    2011-11-01

    This study describes a protocol for the direct manufacturing of a customized titanium mesh using CAD-CAM procedures and rapid prototyping to augment maxillary bone and minimize surgery when severe atrophy or post-oncological deformities are present. Titanium mesh and particulate autogenous plus bovine demineralised bone were planned for patient rehabilitation. Bone augmentation planning was performed using the pre-op CT data set in relation to the prosthetic demands, minimizing the bone volume to augment at the minimum necessary for implants. The containment mesh design was used to prototype the 0.6 mm thickness customized titanium mesh, by direct metal laser sintering. The levels of regenerated bone were calculated using the post-op CT data set, through comparison with the pre-op CT data set. The mean vertical height difference of the crestal bone was 2.57 mm, while the mean buccal-palatal dimension of thickness difference was 3.41 mm. All planned implants were positioned after an 8 month healing period using two-step implant surgery, and finally restored with a partial fixed prosthesis. We present a viable and reproducible method to determine the correct bone augmentation prior to implant placement and CAD-CAM to produce a customized direct laser-sintered titanium mesh that can be used for bone regeneration.

  8. Fused Filament Fabrication of Prosthetic Components for Trans-Humeral Upper Limb Prosthetics

    Science.gov (United States)

    Lathers, Steven M.

    Presented below is the design and fabrication of prosthetic components consisting of an attachment, tactile sensing, and actuator systems with Fused Filament Fabrication (FFF) technique. The attachment system is a thermoplastic osseointegrated upper limb prosthesis for average adult trans-humeral amputation with mechanical properties greater than upper limb skeletal bone. The prosthetic designed has: a one-step surgical process, large cavities for bone tissue ingrowth, uses a material that has an elastic modulus less than skeletal bone, and can be fabricated on one system. FFF osseointegration screw is an improvement upon the current two-part osseointegrated prosthetics that are composed of a fixture and abutment. The current prosthetic design requires two invasive surgeries for implantation and are made of titanium, which has an elastic modulus greater than bone. An elastic modulus greater than bone causes stress shielding and overtime can cause loosening of the prosthetic. The tactile sensor is a thermoplastic piezo-resistive sensor for daily activities for a prosthetic's feedback system. The tactile sensor is manufactured from a low elastic modulus composite comprising of a compressible thermoplastic elastomer and conductive carbon. Carbon is in graphite form and added in high filler ratios. The printed sensors were compared to sensors that were fabricated in a gravity mold to highlight the difference in FFF sensors to molded sensors. The 3D printed tactile sensor has a thickness and feel similar to human skin, has a simple fabrication technique, can detect forces needed for daily activities, and can be manufactured in to user specific geometries. Lastly, a biomimicking skeletal muscle actuator for prosthetics was developed. The actuator developed is manufactured with Fuse Filament Fabrication using a shape memory polymer composite that has non-linear contractile and passive forces, contractile forces and strains comparable to mammalian skeletal muscle, reaction

  9. Titanium and titanium alloys: fundamentals and applications

    National Research Council Canada - National Science Library

    Leyens, C; Peters, M

    2003-01-01

    ... number of titanium alloys have paved the way for light metals to vastly expand into many industrial applications. Titanium and its alloys stand out primarily due to their high specific strength and excellent corrosion resistance, at just half the weight of steels and Ni-based superalloys. This explains their early success in the aerospace and the...

  10. Coronary artery assessment by multidetector computed tomography in patients with prosthetic heart valves

    International Nuclear Information System (INIS)

    Habets, Jesse; Mali, Willem P.T.M.; Budde, Ricardo P.J.; Brink, Renee B.A. van den; Uijlings, Ruben; Spijkerboer, Anje M.; Chamuleau, Steven A.J.

    2012-01-01

    Patients with prosthetic heart valves may require assessment for coronary artery disease. We assessed whether valve artefacts hamper coronary artery assessment by multidetector CT. ECG-gated or -triggered CT angiograms were selected from our PACS archive based on the presence of prosthetic heart valves. The best systolic and diastolic axial reconstructions were selected for coronary assessment. Each present coronary segment was scored for the presence of valve-related artefacts prohibiting coronary artery assessment. Scoring was performed in consensus by two observers. Eighty-two CT angiograms were performed on a 64-slice (n = 27) or 256-slice (n = 55) multidetector CT. Eighty-nine valves and five annuloplasty rings were present. Forty-three out of 1160 (3.7%) present coronary artery segments were non-diagnostic due to valve artefacts (14/82 patients). Valve artefacts were located in right coronary artery (15/43; 35%), left anterior descending artery (2/43; 5%), circumflex artery (14/43; 32%) and marginal obtuse (12/43; 28%) segments. All cobalt-chrome containing valves caused artefacts prohibiting coronary assessment. Biological and titanium-containing valves did not cause artefacts except for three specific valve types. Most commonly implanted prosthetic heart valves do not hamper coronary assessment on multidetector CT. Cobalt-chrome containing prosthetic heart valves preclude complete coronary artery assessment because of severe valve artefacts. circle Most commonly implanted prosthetic heart valves do not hamper coronary artery assessment circle Prosthetic heart valve composition determines the occurrence of prosthetic heart valve-related artefacts circle Bjoerk-Shiley and Sorin tilting disc valves preclude diagnostic coronary artery segment assessment. (orig.)

  11. Technological aspects regarding machining the titanium alloys by means of incremental forming

    Directory of Open Access Journals (Sweden)

    Bologa Octavian

    2017-01-01

    Full Text Available Titanium alloys are materials with reduced formability, due to their low plasticity. However, today there are high demands regarding their use in the automotive industry and in bio-medical industry, for prosthetic devices. This paper presents some technological aspects regarding the machinability of titanium alloys by means of incremental forming. The research presented in this paper aimed to demonstrate that the parts made from these materials could be machined at room temperature, in certain technological conditions.

  12. Prosthetic Aortic Valve Fixation Study: 48 Replacement Valves Analyzed Using Digital Pressure Mapping.

    Science.gov (United States)

    Lee, Candice Y; Wong, Joshua K; Ross, Ronald E; Liu, David C; Khabbaz, Kamal R; Martellaro, Angelo J; Gorea, Heather R; Sauer, Jude S; Knight, Peter A

    Prostheses attachment is critical in aortic valve replacement surgery, yet reliable prosthetic security remains a challenge. Accurate techniques to analyze prosthetic fixation pressures may enable the use of fewer sutures while reducing the risk of paravalvular leaks (PVL). Customized digital thin film pressure transducers were sutured between aortic annulus models and 21-mm bioprosthetic valves with 15 × 4-mm, 12 × 4-mm, or 9 × 6-mm-wide pledgeted mattress sutures. Simulating open and minimally invasive access, 4 surgeons, blinded to data acquisition, each secured 12 valves using manual knot-tying (hand-tied [HT] or knot-pusher [KP]) or automated titanium fasteners (TFs). Real-time pressure measurements and times were recorded. Two-dimensional (2D) and 3D pressure maps were generated for all valves. Pressures less than 80 mm Hg were considered at risk for PVL. Pressures under each knot (intrasuture) fell less than 80 mm Hg for 12 of 144 manual knots (5/144 HT, 7/144 KP) versus 0 of 288 TF (P prosthetic valve security.

  13. Titanium and polyether ether ketone (PEEK) patient-specific sub-periosteal implants: two novel approaches for rehabilitation of the severely atrophic anterior maxillary ridge.

    Science.gov (United States)

    Mounir, M; Atef, M; Abou-Elfetouh, A; Hakam, M M

    2018-05-01

    The aim of this study was to assess two new protocols for single-stage rehabilitation of the severely atrophic maxillary ridge using customized porous titanium or polyether ether ketone (PEEK) sub-periosteal implants. Ten patients with a severely atrophic anterior maxillary alveolar ridge were divided randomly into two groups (five patients in each) to receive customized sub-periosteal implants fabricated via CAD/CAM technology: group 1, porous titanium implants; group 2, PEEK implants. Prosthetic loading with fixed acrylic bridges was performed 1 month postoperative. The implants were followed-up for 12 months and evaluated for the presence of any sign of radiographic bone resorption, mobility, infection, prosthetic fracture, or implant exposure. The immediate postoperative period was uneventful except for one case complicated by wound dehiscence in group 1. At 12 months, all implants were functionally stable and the patients were comfortable with the prostheses. No signs of radiographic bone resorption, mobility, infection, or prosthetic fracture were observed. Within the limitations of this study, the application of customized porous titanium and PEEK sub-periosteal implants produced through CAD/CAM technology appears to be an acceptable method for single-stage prosthetic rehabilitation of the severely atrophic edentulous anterior maxilla. This study was awarded the best case study at the academy of osseintegration annual meeting 2017, Orlando, Florida. Copyright © 2017 International Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  14. Advanced upper limb prosthetic devices: implications for upper limb prosthetic rehabilitation.

    Science.gov (United States)

    Resnik, Linda; Meucci, Marissa R; Lieberman-Klinger, Shana; Fantini, Christopher; Kelty, Debra L; Disla, Roxanne; Sasson, Nicole

    2012-04-01

    The number of catastrophic injuries caused by improvised explosive devices in the Afghanistan and Iraq Wars has increased public, legislative, and research attention to upper limb amputation. The Department of Veterans Affairs (VA) has partnered with the Defense Advanced Research Projects Agency and DEKA Integrated Solutions to optimize the function of an advanced prosthetic arm system that will enable greater independence and function. In this special communication, we examine current practices in prosthetic rehabilitation including trends in adoption and use of prosthetic devices, financial considerations, and the role of rehabilitation team members in light of our experiences with a prototype advanced upper limb prosthesis during a VA study to optimize the device. We discuss key challenges in the adoption of advanced prosthetic technology and make recommendations for service provision and use of advanced upper limb prosthetics. Rates of prosthetic rejection are high among upper limb amputees. However, these rates may be reduced with sufficient training by a highly specialized, multidisciplinary team of clinicians, and a focus on patient education and empowerment throughout the rehabilitation process. There are significant challenges emerging that are unique to implementing the use of advanced upper limb prosthetic technology, and a lack of evidence to establish clinical guidelines regarding prosthetic prescription and treatment. Finally, we make recommendations for future research to aid in the identification of best practices and development of policy decisions regarding insurance coverage of prosthetic rehabilitation. Copyright © 2012 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  15. Sol-gel synthesis of 45S5 bioglass – Prosthetic coating by electrophoretic deposition

    Directory of Open Access Journals (Sweden)

    Faure Joel

    2013-11-01

    Full Text Available In this work, the 45S5 bioactive glass has been prepared by the sol-gel process using an organic acid catalyst instead of nitric acid usually used. The physico-chemical and structural characterizations confirmed and validated the elemental composition of the resulting glass. In addition, the 45S5 bioactive glass powder thus obtained was successfully used to elaborate by electrophoretic deposition a prosthetic coating on titanium alloy Ti6Al4V.

  16. Microbial Biofilms and Breast Tissue Expanders

    Directory of Open Access Journals (Sweden)

    Melissa J. Karau

    2013-01-01

    Full Text Available We previously developed and validated a vortexing-sonication technique for detection of biofilm bacteria on the surface of explanted prosthetic joints. Herein, we evaluated this technique for diagnosis of infected breast tissue expanders and used it to assess colonization of breast tissue expanders. From April 2008 to December 2011, we studied 328 breast tissue expanders at Mayo Clinic, Rochester, MN, USA. Of seven clinically infected breast tissue expanders, six (85.7% had positive cultures, one of which grew Propionibacterium species. Fifty-two of 321 breast tissue expanders (16.2%, 95% CI, 12.3–20.7% without clinical evidence of infection also had positive cultures, 45 growing Propionibacterium species and ten coagulase-negative staphylococci. While vortexing-sonication can detect clinically infected breast tissue expanders, 16 percent of breast tissue expanders appear to be asymptomatically colonized with normal skin flora, most commonly, Propionibacterium species.

  17. Comparative analysis of adherence, viability, proliferation and morphology of umbilical cord tissue-derived mesenchymal stem cells seeded on different titanium-coated expanded polytetrafluoroethylene scaffolds

    International Nuclear Information System (INIS)

    Hollweck, Trixi; Marschmann, Michaela; Hartmann, Isabel; Akra, Bassil; Meiser, Bruno; Reichart, Bruno; Eissner, Guenther; Eblenkamp, Markus; Wintermantel, Erich

    2010-01-01

    Umbilical cord tissue comprises an attractive new source for mesenchymal stem cells. Umbilical cord tissue-derived mesenchymal stem cells (UCMSC) exhibit self-renewal, multipotency and immunological naivity, and they can be obtained without medical intervention. The transfer of UCMSC to the ischemic region of the heart may have a favorable impact on tissue regeneration. Benefit from typical cell delivery by injection to the infarcted area is often limited due to poor cell retention and survival. Another route of administration is to use populated scaffolds implanted into the infarcted zone. In this paper, the seeding efficiency of UCMSC on uncoated and titanium-coated expanded polytetrafluoroethylene (ePTFE) scaffolds with different surface structures was determined. Dualmesh (registered) (DM) offers a corduroy-like surface in contrast to the comparatively planar surface of cardiovascular patch (CVP). The investigation of adherence, viability and proliferation of UCMSC demonstrates that titanium-coated scaffolds are superior to uncoated scaffolds, independent of the surface structure. Microscopic images reveal spherical UCMSC seeded on uncoated scaffolds. In contrast, UCMSC on titanium-coated scaffolds display their characteristic spindle-shaped morphology and a homogeneous coverage of CVP. In summary, titanium coating of clinically approved CVP enhances the retention of UCMSC and thus offers a potential cell delivery system for the repair of the damaged myocardium.

  18. Comparative analysis of adherence, viability, proliferation and morphology of umbilical cord tissue-derived mesenchymal stem cells seeded on different titanium-coated expanded polytetrafluoroethylene scaffolds

    Energy Technology Data Exchange (ETDEWEB)

    Hollweck, Trixi; Marschmann, Michaela; Hartmann, Isabel; Akra, Bassil; Meiser, Bruno; Reichart, Bruno; Eissner, Guenther [Department of Cardiac Surgery, University of Munich, Marchioninistrasse 15, 81377 Munich (Germany); Eblenkamp, Markus; Wintermantel, Erich, E-mail: Guenther.Eissner@med.uni-muenchen.d [Chair of Medical Engineering, Technische Universitaet Muenchen, Boltzmannstrasse 15, 85748 Garching (Germany)

    2010-12-15

    Umbilical cord tissue comprises an attractive new source for mesenchymal stem cells. Umbilical cord tissue-derived mesenchymal stem cells (UCMSC) exhibit self-renewal, multipotency and immunological naivity, and they can be obtained without medical intervention. The transfer of UCMSC to the ischemic region of the heart may have a favorable impact on tissue regeneration. Benefit from typical cell delivery by injection to the infarcted area is often limited due to poor cell retention and survival. Another route of administration is to use populated scaffolds implanted into the infarcted zone. In this paper, the seeding efficiency of UCMSC on uncoated and titanium-coated expanded polytetrafluoroethylene (ePTFE) scaffolds with different surface structures was determined. Dualmesh (registered) (DM) offers a corduroy-like surface in contrast to the comparatively planar surface of cardiovascular patch (CVP). The investigation of adherence, viability and proliferation of UCMSC demonstrates that titanium-coated scaffolds are superior to uncoated scaffolds, independent of the surface structure. Microscopic images reveal spherical UCMSC seeded on uncoated scaffolds. In contrast, UCMSC on titanium-coated scaffolds display their characteristic spindle-shaped morphology and a homogeneous coverage of CVP. In summary, titanium coating of clinically approved CVP enhances the retention of UCMSC and thus offers a potential cell delivery system for the repair of the damaged myocardium.

  19. Reactive Spark Plasma Sintering (SPS) of Nitride Reinforced Titanium Alloy Composites (Postprint)

    Science.gov (United States)

    2014-08-15

    other industrial applications [21–25]. Titanium is widely used in the medical field to replace heart valves , joints, and bones for dental prosthetics due...their wear and fatigue resistance, hard coatings for dental implants and dental surgery tools, tribological orthopedic devices, gears, valves , pumps...their inherent brittleness and inferior fracture toughness [6,10–13]. In contrast, metal matrix composites (MMCs) reinforced with hard precipitates

  20. Mechanical Properties of Abutments: Resin-Bonded Glass Fiber-Reinforced Versus Titanium.

    Science.gov (United States)

    Bassi, Mirko Andreasi; Bedini, Rosells; Pecci, Raffaela; Ioppolo, Pietro; Laritano, Dorina; Carinci, Francesco

    2016-01-01

    The clinical success and longevity of endosseous implants, after their prosthetic finalization, mainly depends on mechanical factors. Excessive mechanical stress has been shown to cause initial bone loss around implants in the presence of a rigid implant-prosthetic connection. The implant abutments are manufactured with high elastic modulus materials such as titanium, steel, precious alloys, or esthetic ceramics. These materials do not absorb any type of shock from the chewing loads or ensure protection of the bone-implant interface, especially when the esthetic restorative material is ceramic rather than composite resin. The mechanical resistance to cyclical load was evaluated in a tooth-colored fiber-reinforced abutment prototype (TCFRA) and compared to that of a similarly shaped titanium abutment (TA). Eight TCFRAs and eight TAs were adhesively cemented on as many titanium implants. The swinging the two types of abutments showed during the application of sinusoidal load was also analyzed. In the TA group, fracture and deformation occurred in 12.5% of samples, while debonding occurred in 62.5%. In the TCFRA group, only debonding was present, in 37.5% of samples. In comparison to the TAs, the TCFRAs exhibited greater swinging during the application of sinusoidal load. In the TA group extrusion prevailed, whereas in the TCFRA group intrusion was more frequent. TCFRA demonstrated a greater elasticity than did TAs to the flexural load, absorbing part of the transversal load applied on the fixture during the chewing function and thus reducing the stress on the bone-implant interface.

  1. An Evaluation of Dental Prosthetic Status and Prosthetic Needs ...

    African Journals Online (AJOL)

    present cross‑sectional study aimed to evaluate the dental prosthetic status and prosthetic needs among eunuchs .... who consented to become part of the study guided us to the .... to the reason that our study population comprised of adults with low SES. ... Arora M, Schwarz E, Sivaneswaran S, Banks E. Cigarette smoking.

  2. Using computed tomography and 3D printing to construct custom prosthetics attachments and devices.

    Science.gov (United States)

    Liacouras, Peter C; Sahajwalla, Divya; Beachler, Mark D; Sleeman, Todd; Ho, Vincent B; Lichtenberger, John P

    2017-01-01

    The prosthetic devices the military uses to restore function and mobility to our wounded warriors are highly advanced, and in many instances not publically available. There is considerable research aimed at this population of young patients who are extremely active and desire to take part in numerous complex activities. While prosthetists design and manufacture numerous devices with standard materials and limb assemblies, patients often require individualized prosthetic design and/or modifications to enable them to participate fully in complex activities. Prosthetists and engineers perform research and implement digitally designs in collaboration to generate equipment for their patient's rehabilitation needs. 3D printing allows for these devices to be manufactured from an array of materials ranging from plastic to titanium alloy. Many designs require form fitting to a prosthetic socket or a complex surface geometry. Specialty items can be scanned using computed tomography and digitally reconstructed to produce a virtual 3D model the engineer can use to design the necessary features of the desired prosthetic, device, or attachment. Completed devices are tested for fit and function. Numerous custom prostheses and attachments have been successfully translated from the research domain to clinical reality, in particular, those that feature the use of computed tomography (CT) reconstructions. The purpose of this project is to describe the research pathways to implementation for the following clinical designs: sets of bilateral hockey skates; custom weightlifting prosthetic hands; and a wine glass holder. This article will demonstrate how to incorporate CT imaging and 3D printing in the design and manufacturing process of custom attachments and assistive technology devices. Even though some of these prosthesis attachments may be relatively simple in design to an engineer, they have an enormous impact on the lives of our wounded warriors.

  3. Prevention of Prosthetic Dentistry

    Directory of Open Access Journals (Sweden)

    Eremin O.V.

    2011-03-01

    Full Text Available Prevention in prosthetic dentistry is not just a regular oral hygiene and the prevention of caries in the early stages of its development. The initial goal of orthopedic and dental should be the ability to convey to the patient's sense of pros-thetics that proteziruya one saved more. An example is included prosthetic dental arch defects with bridges or single artificial crowns on implants that will prevent movement of teeth and the continuity of the dentition

  4. New titanium and titanium/hydroxyapatite coatings on ultra-high-molecular-weight polyethylene-in vitro osteoblastic performance

    International Nuclear Information System (INIS)

    Silva, M A; Lopes, M A; Santos, J D; Fernandes, M H; Gomes, P S; Vila, M; Silva, R F

    2010-01-01

    The development of optimized hip joint materials is one of the most challenging opportunities in prosthetic technologies. In current approaches, ultra-high-molecular-weight polyethylene (UHMWPE) has been a favorite material for the acetabular component and, regarding the cementless technique, several coating options may be considered to contain and stabilize bearing surfaces and establish an improved interface with bone. In this work, newly developed constructs of UHMWPE coated with either commercially pure titanium (cpTi-UHMWPE), by DC magnetron sputtering, or with commercially pure titanium and hydroxyapatite (cpTi/HA-UHMWPE), by DC/RF magnetron co-sputtering, have been prepared and biologically characterized with human bone marrow-derived osteoblastic cultures. The cpTi-UHMWPE samples allowed a high cell growth and the expression of the complete osteoblastic phenotype, with high alkaline phosphatase activity, expression of osteogenic-associated genes and evident cell-mediated mineralization of the extracellular matrix. In comparison, the cpTi/HA-UHMWPE samples reported lower cell proliferation but earlier cell-mediated matrix mineralization. Accordingly, these newly developed systems may be suitable candidates to improve the osteointegration process in arthroplastic devices; nevertheless, further biological evaluation should be conducted.

  5. 3D Printing/Additive Manufacturing Single Titanium Dental Implants: A Prospective Multicenter Study with 3 Years of Follow-Up.

    Science.gov (United States)

    Tunchel, Samy; Blay, Alberto; Kolerman, Roni; Mijiritsky, Eitan; Shibli, Jamil Awad

    2016-01-01

    This prospective 3-year follow-up clinical study evaluated the survival and success rates of 3DP/AM titanium dental implants to support single implant-supported restorations. After 3 years of loading, clinical, radiographic, and prosthetic parameters were assessed; the implant survival and the implant-crown success were evaluated. Eighty-two patients (44 males, 38 females; age range 26-67 years) were enrolled in the present study. A total of 110 3DP/AM titanium dental implants (65 maxilla, 45 mandible) were installed: 75 in healed alveolar ridges and 35 in postextraction sockets. The prosthetic restorations included 110 single crowns (SCs). After 3 years of loading, six implants failed, for an overall implant survival rate of 94.5%; among the 104 surviving implant-supported restorations, 6 showed complications and were therefore considered unsuccessful, for an implant-crown success of 94.3%. The mean distance between the implant shoulder and the first visible bone-implant contact was 0.75 mm (±0.32) and 0.89 (±0.45) after 1 and 3 years of loading, respectively. 3DP/AM titanium dental implants seem to represent a successful clinical option for the rehabilitation of single-tooth gaps in both jaws, at least until 3-year period. Further, long-term clinical studies are needed to confirm the present results.

  6. 3D Printing/Additive Manufacturing Single Titanium Dental Implants: A Prospective Multicenter Study with 3 Years of Follow-Up

    Directory of Open Access Journals (Sweden)

    Samy Tunchel

    2016-01-01

    Full Text Available This prospective 3-year follow-up clinical study evaluated the survival and success rates of 3DP/AM titanium dental implants to support single implant-supported restorations. After 3 years of loading, clinical, radiographic, and prosthetic parameters were assessed; the implant survival and the implant-crown success were evaluated. Eighty-two patients (44 males, 38 females; age range 26–67 years were enrolled in the present study. A total of 110 3DP/AM titanium dental implants (65 maxilla, 45 mandible were installed: 75 in healed alveolar ridges and 35 in postextraction sockets. The prosthetic restorations included 110 single crowns (SCs. After 3 years of loading, six implants failed, for an overall implant survival rate of 94.5%; among the 104 surviving implant-supported restorations, 6 showed complications and were therefore considered unsuccessful, for an implant-crown success of 94.3%. The mean distance between the implant shoulder and the first visible bone-implant contact was 0.75 mm (±0.32 and 0.89 (±0.45 after 1 and 3 years of loading, respectively. 3DP/AM titanium dental implants seem to represent a successful clinical option for the rehabilitation of single-tooth gaps in both jaws, at least until 3-year period. Further, long-term clinical studies are needed to confirm the present results.

  7. GIANT PROSTHETIC VALVE THROMBUS

    Directory of Open Access Journals (Sweden)

    Prashanth Kumar

    2015-04-01

    Full Text Available Mechanical prosthetic valves are predisposed to bleeding, thrombosis & thromboembolic complications. Overall incidence of thromboembolic complications is 1% per year who are on oral anticoagulants, whereas bleeding complications incidence is 0.5% to 6.6% per year. 1, 2 Minimization of Scylla of thromboembolic & Charybdis of bleeding complication needs a balancing act of optimal antithrombotic therapy. We are reporting a case of middle aged male patient with prosthetic mitral valve presenting in heart failure. Patient had discontinued anticoagulants, as he had subdural hematoma in the past. He presented to our institute with a giant prosthetic valve thrombus.

  8. Prosthetic Joint Infections

    Science.gov (United States)

    Aslam, Saima; Darouiche, Rabih O.

    2012-01-01

    Prosthetic joint infections represent a major therapeutic challenge for both healthcare providers and patients. This paper reviews the predisposing factors, pathogenesis, microbiology, diagnosis, treatment and prophylaxis of prosthetic joint infection. The most optimal management strategy should be identified based on a number of considerations including type and duration of infection, antimicrobial susceptibility of the infecting pathogen, condition of infected tissues and bone stock, patient wishes and functional status. PMID:22847032

  9. Pregnancy after Prosthetic Aortic Valve Replacement: How Do We Monitor Prosthetic Valvular Function during Pregnancy?

    Directory of Open Access Journals (Sweden)

    Nicole Sahasrabudhe

    2018-01-01

    Full Text Available Background. With modern medicine, many women after structural heart repair are deciding to experience pregnancy. There is a need for further study to identify normal echocardiographic parameters to better assess prosthetic valvular function in pregnancy. In addition, a multidisciplinary approach is essential in managing pregnant patients with complex cardiac conditions. Case. A 22-year-old nulliparous woman with an aortic valve replacement 18 months prior to her pregnancy presented to prenatal care at 20-week gestation. During her prenatal care, serial echocardiography showed a significant increase in the mean gradient across the prosthetic aortic valve. Multidisciplinary management and a serial echocardiography played an integral role in her care that resulted in a successful spontaneous vaginal delivery without complications. Conclusion. Further characterization of the normal echocardiographic parameters in pregnant patients with prosthetic valves is critical to optimize prenatal care for this patient population. This case report is novel in that serial echocardiograms were obtained throughout prenatal care, which showed significant changes across the prosthetic aortic valve. Teaching Points. (1 Further study is needed to identify normal echocardiographic parameters to best assess prosthetic valvular function in pregnancy. (2 Multidisciplinary management is encouraged to optimize prenatal care for women with prosthetic aortic valve replacements.

  10. Prosthetic vascular graft infection and prosthetic joint infection caused by Pseudomonas stutzeri.

    Science.gov (United States)

    Bonares, Michael J; Vaisman, Alon; Sharkawy, Abdu

    2016-01-01

    Pseudomonas stutzeri is infrequently isolated from clinical specimens, and if isolated, more likely represents colonization or contamination rather than infection. Despite this, there are dozens of case reports which describe clinically significant P. stutzeri infections at variable sites. A 69-year-old man had a P. stutzeri infection of a prosthetic vascular graft infection, which he received in Panama City. He was successfully treated with a single antipseudomonal agent for 6 weeks and the removal of the infected vascular graft. A 70-year-old man had a P. stutzeri infection of a prosthetic joint, which was successfully treated with a single anti-pseudomonal agent for 6 weeks. There is only one other documented case of a prosthetic vascular graft infection secondary to P. stutzeri . There are 5 documented cases of P. stutzeri prosthetic joint infections. The previous cases were treated with antibiotics and variably, source control with the removal of prosthetic material. Most cases of P. stutzeri infection are due to exposure in health care settings. Immunocompromised states such as HIV or hematological and solid tumor malignancies are risk factors for P. stutzeri infection. Infections caused by P. stutzeri are far less frequent and less fatal than those caused by P. aeruginosa. The etiology of a P. stutzeri infection could be exposure to soil and water, but also contaminated material in the health care setting or an immunocompromised state. Iatrogenic infections that are secondary to health care tourism are a potential cause of fever in the returned traveler.

  11. Isolated Lactobacillus chronic prosthetic knee infection.

    Science.gov (United States)

    Bennett, David M; Shekhel, Tatyana; Radelet, Matt; Miller, Michael D

    2014-01-01

    Lactobacillus is a gram-positive rod bacteria found primarily in the gastrointestinal and female genital tracts. Prosthetic infections in implants are being increasingly reported. The authors present a case of a 58-year-old patient with Lactobacillus septic prosthetic knee joint infection. To the authors’ knowledge, this is the first reported case of chronic prosthetic knee infection with isolated Lactobacillus species. Lactobacillus has been most commonly implicated with bacteremia and endocarditis and rarely with pneumonia, meningitis, and endovascular infection, and a vast majority of the cases are reported in immunocompromised patients. In the current case, diabetes mellitus, hepatitis, malnutrition, anemia, and liver failure were comorbid conditions, placing the patient at increased risk of infection. The findings suggest that further case series are necessary to establish the significance of Lactobacillus as an etiologic agent in chronic low-virulence, and potentially vancomycin-resistant, prosthetic joint infection. The need also exists for further research aimed at the risk of prosthetic joint infection with oral intake of certain probiotic foods and supplements. The goal of this case report is to bring to light the potential of this organism to be a cause of subtle chronic prosthetic joint infection.

  12. Computer Aided Facial Prosthetics Manufacturing System

    Directory of Open Access Journals (Sweden)

    Peng H.K.

    2016-01-01

    Full Text Available Facial deformities can impose burden to the patient. There are many solutions for facial deformities such as plastic surgery and facial prosthetics. However, current fabrication method of facial prosthetics is high-cost and time consuming. This study aimed to identify a new method to construct a customized facial prosthetic. A 3D scanner, computer software and 3D printer were used in this study. Results showed that the new developed method can be used to produce a customized facial prosthetics. The advantages of the developed method over the conventional process are low cost, reduce waste of material and pollution in order to meet the green concept.

  13. Implant-prosthetic rehabilitation after radiation treatment in head and neck cancer patients: a case-series report of outcome

    Directory of Open Access Journals (Sweden)

    Cotic Jasna

    2016-02-01

    Full Text Available Slovenia has a high burden of head and neck cancer. Patients are mostly treated with surgery followed by radiation therapy. Advanced surgical and prosthodontic techniques have expanded the rehabilitation options. The aim of the study was to review the outcome of implant-prosthetic treatment after radiation therapy.

  14. The role of osteoblasts in peri-prosthetic osteolysis.

    LENUS (Irish Health Repository)

    O'Neill, S C

    2013-08-01

    Peri-prosthetic osteolysis and subsequent aseptic loosening is the most common reason for revising total hip replacements. Wear particles originating from the prosthetic components interact with multiple cell types in the peri-prosthetic region resulting in an inflammatory process that ultimately leads to peri-prosthetic bone loss. These cells include macrophages, osteoclasts, osteoblasts and fibroblasts. The majority of research in peri-prosthetic osteolysis has concentrated on the role played by osteoclasts and macrophages. The purpose of this review is to assess the role of the osteoblast in peri-prosthetic osteolysis. In peri-prosthetic osteolysis, wear particles may affect osteoblasts and contribute to the osteolytic process by two mechanisms. First, particles and metallic ions have been shown to inhibit the osteoblast in terms of its ability to secrete mineralised bone matrix, by reducing calcium deposition, alkaline phosphatase activity and its ability to proliferate. Secondly, particles and metallic ions have been shown to stimulate osteoblasts to produce pro inflammatory mediators in vitro. In vivo, these mediators have the potential to attract pro-inflammatory cells to the peri-prosthetic area and stimulate osteoclasts to absorb bone. Further research is needed to fully define the role of the osteoblast in peri-prosthetic osteolysis and to explore its potential role as a therapeutic target in this condition.

  15. Effect of zirconium nitride physical vapor deposition coating on preosteoblast cell adhesion and proliferation onto titanium screws.

    Science.gov (United States)

    Rizzi, Manuela; Gatti, Giorgio; Migliario, Mario; Marchese, Leonardo; Rocchetti, Vincenzo; Renò, Filippo

    2014-11-01

    Titanium has long been used to produce dental implants. Problems related to its manufacturing, casting, welding, and ceramic application for dental prostheses still limit its use, which highlights the need for technologic improvements. The aim of this in vitro study was to evaluate the biologic performance of titanium dental implants coated with zirconium nitride in a murine preosteoblast cellular model. The purpose of this study was to evaluate the chemical and morphologic characteristics of titanium implants coated with zirconium nitride by means of physical vapor deposition. Chemical and morphologic characterizations were performed by scanning electron microscopy and energy dispersive x-ray spectroscopy, and the bioactivity of the implants was evaluated by cell-counting experiments. Scanning electron microscopy and energy dispersive x-ray spectroscopy analysis found that physical vapor deposition was effective in covering titanium surfaces with zirconium nitride. Murine MC-3T3 preosteoblasts were seeded onto titanium-coated and zirconium nitride-coated screws to evaluate their adhesion and proliferation. These experiments found a significantly higher number of cells adhering and spreading onto zirconium nitride-coated surfaces (Pzirconium nitride surfaces were completely covered with MC-3T3 cells. Analysis of these data indicates that the proposed zirconium nitride coating of titanium implants could make the surface of the titanium more bioactive than uncoated titanium surfaces. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  16. Alveolar Ridge Reconstruction with Titanium Meshes and Simultaneous Implant Placement: A Retrospective, Multicenter Clinical Study

    Directory of Open Access Journals (Sweden)

    Raquel Zita Gomes

    2016-01-01

    Full Text Available Objective. To evaluate horizontal bone gain and implant survival and complication rates in patients treated with titanium meshes placed simultaneously with dental implants and fixed over them. Methods. Twenty-five patients treated with 40 implants and simultaneous guided bone regeneration with titanium meshes (i–Gen®, MegaGen, Gyeongbuk, Republic of Korea were selected for inclusion in the present retrospective multicenter study. Primary outcomes were horizontal bone gain and implant survival; secondary outcomes were biological and prosthetic complications. Results. After the removal of titanium meshes, the CBCT evaluation revealed a mean horizontal bone gain of 3.67 mm (±0.89. The most frequent complications were mild postoperative edema (12/25 patients: 48% and discomfort after surgery (10/25 patients: 40%; these complications were resolved within one week. Titanium mesh exposure occurred in 6 patients (6/25 : 24%: one of these suffered partial loss of the graft and another experienced complete graft loss and implant failure. An implant survival rate of 97.5% (implant-based and a peri-implant marginal bone loss of 0.43 mm (±0.15 were recorded after 1 year. Conclusions. The horizontal ridge reconstruction with titanium meshes placed simultaneously with dental implants achieved predictable satisfactory results. Prospective randomized controlled trials on a larger sample of patients are required to validate these positive outcomes.

  17. Pre-prosthetic surgery: Mandible

    Directory of Open Access Journals (Sweden)

    Veeramalai Naidu Devaki

    2012-01-01

    Full Text Available Pre-prosthetic surgery is that part of oral and maxillofacial surgery which restores oral function and facial form. This is concerned with surgical modification of the alveolar process and its surrounding structures to enable the fabrication of a well-fitting, comfortable, and esthetic dental prosthesis. The ultimate goal of pre-prosthetic surgery is to prepare a mouth to receive a dental prosthesis by redesigning and smoothening bony edges.

  18. Guide to prosthetic cardiac valves

    International Nuclear Information System (INIS)

    Morse, D.; Steiner, R.M.; Fernandez, J.

    1985-01-01

    This book contains 10 chapters. Some of the chapter titles are: The development of artificial heart valves: Introduction and historical perspective; The radiology of prosthetic heart valves; The evaluation of patients for prosthetic valve implantation; Pathology of cardiac valve replacement; and Bioengineering of mechanical and biological heart valve substitutes

  19. Implant-supported titanium prostheses following augmentation procedures: a clinical report.

    Science.gov (United States)

    Knabe, C; Hoffmeister, B

    2003-03-01

    This report describes a novel technique for fabricating retrievable implant-supported titanium (Ti) prostheses in patients requiring a comprehensive treatment plan involving the combined efforts of maxillofacial surgery and implant prosthodontics. Following bone graft reconstructive surgery and implant placement prosthetic treatment was initiated by inserting ITI-Octa abutments. An impression was made, and a framework was fabricated by fusing Ti-cast frameworks to prefabricated titanium copings by laser-welding. This was followed by veneering or fabrication of a removable denture with Ti metal re-enforcement. Favourable clinical results have been achieved using these screw-retained Ti implant-supported restorations for patients treated with reconstructive bone graft-surgery, with clinical observation periods ranging from three to four years. The present observations suggest that these screw-retained implant-supported Ti prostheses may be a meaningful contribution to implant prosthodontics, facilitating retrievable restorations of optimum biocompatibility, good marginal precision and with a good esthetic result. However, controlled clinical studies are needed to establish the long-term serviceability of these Ti restorations.

  20. Prosthetic status and prosthetic need among the patients attending various dental institutes of ahmedabad and gandhinagar district, gujarat.

    Science.gov (United States)

    Shah, Vrinda R; Shah, Darshana N; Parmar, Chaitanya H

    2012-09-01

    The oral health being an integral part for the healthy living, necessity of disability limitation and rehabilitation in oral health has taken a paramount role. To assess the prosthetic status and to evaluate the prosthetic needs of the patients attending various institutes of Ahmedabad and Gandhinagar district. A total of 510 (264 males and 246 females) subjects at various dental institutes were examined in the study. A survey proforma was prepared with the help of WHO oral health assessment form (1997). Prosthetic status and prosthetic treatment need was recorded. Out of 510, any type of Edentulousness was 322 (63 %). Among them, 254 (49.8 %) were partially edentulous while 68 (13.3 %) were completely edentulous. Only 69 (13 %) were having any prosthesis in upper arch while only 80 (16 %) were having any prosthesis in lower arch. Need for any type of prosthesis in upper and lower arch was 55 and 60 % in males and females, respectively. In lower social class group need of prosthesis in upper and lower arch was 62 and 63 %, respectively. It was found that prosthetic status and prosthetic treatment need increased with increase in age. Steps should be taken to overcome this disparity and more emphasis should be given to meet the felt need of the people through government and non government organizations to improve the oral health. The unmet prosthetic treatment need should be met to rehabilitate needy people so that their disability may be limited.

  1. Circuit For Control Of Electromechanical Prosthetic Hand

    Science.gov (United States)

    Bozeman, Richard J., Jr.

    1995-01-01

    Proposed circuit for control of electromechanical prosthetic hand derives electrical control signals from shoulder movements. Updated, electronic version of prosthesis, that includes two hooklike fingers actuated via cables from shoulder harness. Circuit built around favored shoulder harness, provides more dexterous movement, without incurring complexity of computer-controlled "bionic" or hydraulically actuated devices. Additional harness and potentiometer connected to similar control circuit mounted on other shoulder. Used to control stepping motor rotating hand about prosthetic wrist to one of number of angles consistent with number of digital outputs. Finger-control signals developed by circuit connected to first shoulder harness transmitted to prosthetic hand via sliprings at prosthetic wrist joint.

  2. Factors Associated with Prosthetic Looseness in Lower Limb Amputees.

    Science.gov (United States)

    Phonghanyudh, Thong; Sutpasanon, Taweesak; Hathaiareerug, Chanasak; Devakula, M L Buddhibongsa; Kumnerddee, Wipoo

    2015-12-01

    To determine the factors associated with prosthetic looseness in lower limb amputees in Sisaket province. The present was a cross-sectional descriptive study. Subjects were lower limb amputees who previously obtained prostheses and required prosthetic replacements at the mobile prosthetic laboratory unit under the Prostheses Foundation of H.R.H. the Princess Mother at Khun Han Hospital, Sisaket province, in February 2013. Data including participant characteristics, prosthetic looseness data, and various variables were collected by direct semi-structured interview. Energy expenditures in physical activities were measured using the Thai version of the short format international physical activity questionnaire. Data between participants with and without prosthetic looseness were compared to determine prosthetic loosening associated factors. Among 101 participants enrolled, 33 (32.7%) had prosthetic looseness with average onset of 1.76 ± 1.67 years. Diabetes mellitus was the only significant factor associated with prosthetic looseness from both univariate and multivariate analyses (HR = 7.05, p = 0.002 and HR = 5.93, p = 0.007 respectively). Among the lower limb amputees in Sisaket province, diabetes mellitus was the only factor associated with prosthetic looseness. Therefore, diabetic screening should be supplemented in lower limb amputee assessment protocol. In addition, we recommend that amputees with diabetes mellitus should receive prosthesis check out at approximately

  3. [Use and versatility of titanium for the reconstruction of the thoracic wall].

    Science.gov (United States)

    Córcoles Padilla, Juan Manuel; Bolufer Nadal, Sergio; Kurowski, Krzysztof; Gálvez Muñoz, Carlos; Rodriguez Paniagua, José Manuel

    2014-02-01

    Chest wall deformities/defects and chest wall resections, as well as complex rib fractures require reconstruction with various prosthetic materials to ensure the basic functions of the chest wall. Titanium provides many features that make it an ideal material for this surgery. The aim is to present our initial results with this material in several diseases. From 2008 to 2012, 14 patients were operated on and titanium was used for reconstruction of the chest wall. A total of 7 patients had chest wall tumors, 2 with sternal resection, 4 patients with chest wall deformities/defects and 3 patients with severe rib injury due to traffic accident. The reconstruction was successful in all cases, with early extubation without detecting problems in the functionality of the chest wall at a respiratory level. Patients with chest wall tumors including sternal resections were extubated in the operating room as well as the chest wall deformities. Chest trauma cases were extubated within 24h from internal rib fixation. There were no complications related to the material used and the method of implementation. Titanium is an ideal material for reconstruction of the chest wall in several clinical situations allowing for great versatility and adaptability in different chest wall reconstructions. Copyright © 2013 AEC. Published by Elsevier Espana. All rights reserved.

  4. Optimising the prescription of prosthetic technologies (opptec): Outcome measures for evidence based prosthetic practice and use

    LENUS (Irish Health Repository)

    Ryall, Dr Nicola

    2010-01-01

    This study provided a forum for patients and service providers to voice their opinions in what they believe to be the important predictors and outcomes involved in successful rehabilitation following limb loss. To develop a consensus on the most important outcomes and factors to address for both the lower limb and upper limb prosthetic prescription process, the above data relating to lower limb and upper prosthetics were subsequently used in the next phase of the research involving two Delphi surveys of 23 and 53 experts within the lower limb and upper limb amputation and prosthetic field respectively, including users, service providers and researchers.\\r\

  5. Titanium

    Science.gov (United States)

    Woodruff, Laurel G.; Bedinger, George M.; Piatak, Nadine M.; Schulz, Klaus J.; DeYoung,, John H.; Seal, Robert R.; Bradley, Dwight C.

    2017-12-19

    Titanium is a mineral commodity that is essential to the smooth functioning of modern industrial economies. Most of the titanium produced is refined into titanium dioxide, which has a high refractive index and is thus able to impart a durable white color to paint, paper, plastic, rubber, and wallboard. Because of their high strength-to-weight ratio and corrosion resistance, titanium metal and titanium metal alloys are used in the aerospace industry as well as for welding rod coatings, biological implants, and consumer goods.Ilmenite and rutile are currently the principal titanium-bearing ore minerals, although other minerals, including anatase, perovskite, and titanomagnetite, could have economic importance in the future. Ilmenite is currently being mined from two large magmatic deposits hosted in rocks of Proterozoic-age anorthosite plutonic suites. Most rutile and nearly one-half of the ilmenite produced are from heavy-mineral alluvial, fluvial, and eolian deposits. Titanium-bearing minerals occur in diverse geologic settings, but many of the known deposits are currently subeconomic for titanium because of complications related to the mineralogy or because of the presence of trace contaminants that can compromise the pigment production process.Global production of titanium minerals is currently dominated by Australia, Canada, Norway, and South Africa; additional amounts are produced in Brazil, India, Madagascar, Mozambique, Sierra Leone, and Sri Lanka. The United States accounts for about 4 percent of the total world production of titanium minerals and is heavily dependent on imports of titanium mineral concentrates to meet its domestic needs.Titanium occurs only in silicate or oxide minerals and never in sulfide minerals. Environmental considerations for titanium mining are related to waste rock disposal and the impact of trace constituents on water quality. Because titanium is generally inert in the environment, human health risks from titanium and titanium

  6. Vascular complications of prosthetic inter-vertebral discs

    OpenAIRE

    Daly, Kevin J.; Ross, E. Raymond S.; Norris, Heather; McCollum, Charles N.

    2006-01-01

    Five consecutive cases of prosthetic inter-vertebral disc displacement with severe vascular complications on revisional surgery are described. The objective of this case report is to warn spinal surgeons that major vascular complications are likely with anterior displacement of inter-vertebral discs. We have not been able to find a previous report on vascular complications associated with anterior displacement of prosthetic inter-vertebral discs. In all five patients the prosthetic disc had e...

  7. Advanced Prosthetic Gait Training Tool

    Science.gov (United States)

    2015-12-01

    modules to train individuals to distinguish gait deviations (trunk motion and lower-limb motion). Each of these modules help trainers improve their...AWARD NUMBER: W81XWH-10-1-0870 TITLE: Advanced Prosthetic Gait Training Tool PRINCIPAL INVESTIGATOR: Dr. Karim Abdel-Malek CONTRACTING...study is to produce a computer-based Advanced Prosthetic Gait Training Tool to aid in the training of clinicians at military treatment facilities

  8. In vitro comparison of the biological activity of alumina ceramic and titanium particles associated with aseptic loosening

    International Nuclear Information System (INIS)

    Ding Yue; Qin Chuqiang; Xu Jie; Huang Dongsheng; Fu Yuru

    2012-01-01

    Prosthetic wear particles are thought to play a central role in the initiation and development of periprosthetic osteolysis, leading to aseptic loosening of prostheses. This study aimed to compare the biological activity of ceramic and titanium particles that are associated with particle-induced, aseptic joint loosening. Different sizes of alumina-ceramic particles and titanium particles were prepared to stimulate murine macrophage cells RAW 264.7, of which the expressions of tumor necrosis factor alpha (TNF-alpha) and receptor activator of nuclear factor-κB ligand (RANKL) were measured by qPCR and ELISA at various time points. In the presence of all particles, the expression of TNF-alpha increased in a time-dependent manner, whereas the expression of RANKL showed no regular expression patterns. Notably, particles of smaller sizes provoked significantly higher levels of TNF-alpha and RANKL than those of larger sizes. Compared to the titanium particles, the ceramic particles provoked a significantly lower production of TNF-alpha. Thus, the bioactivities of titanium and alumina ceramic particles were inversely proportional to the sizes of the particles, and the expression of RANKL was not parallel to that of TNF-alpha. The successful outcome of ceramic-on-ceramic artificial joint prostheses may be attributed to the low biological activity of ceramic particles, as evidenced here. (paper)

  9. Prosthetic Engineering

    Science.gov (United States)

    ... the household and community environments may lead to falls and injuries. This research aims to develop an ankle that can invert and evert and thereby control the center of pressure under the prosthetic foot; enhancing balance and stability of lower limb amputees. Foot-Ankle ...

  10. Second-site prosthetic joint infection in patients with multiple prosthetic joints.

    Science.gov (United States)

    Clesham, Kevin; Hughes, Andrew J; O' hEireamhoin, Sven; Fleming, Catherine; Murphy, Colin G

    2018-04-10

    Prosthetic joint infections (PJIs) are among the most serious complications in arthroplasty. A second-site PJI in patients with multiple prosthetic joints increases morbidity, with many requiring further revision procedures. We aimed to establish why some patients with multiple joints develop second-site infections. Our institution's arthroplasty database was reviewed from 2004 to 2017. All PJIs were identified, and all patients with more than one prosthetic joint in situ were included. We recorded risk factors, causative organisms, number of procedures and length of stay. Forty-four patients meeting the criteria were identified. Four patients (9.1%) developed second-site infection. Eight patients (18.2%) developed re-infection of the primary PJI. Positive MRSA carrier status and PJI of a total knee replacement were associated with an increased risk of a second episode of infection. Patients who developed further infection had more frequent admission and longer lengths of stay than isolated PJIs. Higher morbidity and use of hospital resources are associated with this cohort of patients. PJIs in total knee replacements and positive MRSA status are associated with higher rates of second infection. Identifying this vulnerable cohort of patients at an early stage is critical to ensure measures are taken to reduce the risks of further infection.

  11. Virtual surgical planning and 3D printing in prosthetic orbital reconstruction with percutaneous implants: a technical case report.

    Science.gov (United States)

    Huang, Yu-Hui; Seelaus, Rosemary; Zhao, Linping; Patel, Pravin K; Cohen, Mimis

    2016-01-01

    Osseointegrated titanium implants to the cranial skeleton for retention of facial prostheses have proven to be a reliable replacement for adhesive systems. However, improper placement of the implants can jeopardize prosthetic outcomes, and long-term success of an implant-retained prosthesis. Three-dimensional (3D) computer imaging, virtual planning, and 3D printing have become accepted components of the preoperative planning and design phase of treatment. Computer-aided design and computer-assisted manufacture that employ cone-beam computed tomography data offer benefits to patient treatment by contributing to greater predictability and improved treatment efficiencies with more reliable outcomes in surgical and prosthetic reconstruction. 3D printing enables transfer of the virtual surgical plan to the operating room by fabrication of surgical guides. Previous studies have shown that accuracy improves considerably with guided implantation when compared to conventional template or freehand implant placement. This clinical case report demonstrates the use of a 3D technological pathway for preoperative virtual planning through prosthesis fabrication, utilizing 3D printing, for a patient with an acquired orbital defect that was restored with an implant-retained silicone orbital prosthesis.

  12. Development of nylon-based artificial muscles for the usage in robotic prosthetic limb

    Science.gov (United States)

    Atikah, Nurul Anis; Weng, Leong Yeng; Anuar, Adzly; Fat, Chau Chien; Abidin, Izham Zainal; Sahari, Khairul Salleh Mohamed

    2017-09-01

    This paper describes the development of nylon-based artificial muscles that is intended to be used in prosthetic limb for young amputees. Prosthetic limbs are very expensive and this situation is further compounded for young amputees who are very quickly out-grow their prosthesis. The proposed artificial muscles are made of nylon fishing strings from various size such as 0.45mm, 0.55mm, 0.65mm and 1.00mm. These fishing strings were twisted into coils to create Super Coiled Polymers (SCP) and tested using hot air blower. These artificial muscles react counterintuitively, where when it is exposed to heat, contracts, and when cooled, expands. Peltier devices, when switched-on acts as heat pump, where one side is hot and the other is cold. This phenomenon, when affixed in between 2 SCP's, creates tandem motion similar to triceps and biceps. As initial study, the hot side of the Peltier module was tested using these artificial muscles. The string was measured for both its force production, length contraction, the initial results were promising.

  13. Review of Prosthetic Joint Infection from Listeria monocytogenes.

    Science.gov (United States)

    Bader, Gilbert; Al-Tarawneh, Mohammed; Myers, James

    2016-12-01

    Prosthetic joint infection from Listeria monocytogenes is rare. We decided to shed light on this illness and review the reported cases to better understand its characteristics. We conducted a comprehensive review of the English literature using PubMed. We also included one case that we had managed. We found 25 cases of prosthetic joint infection from L. monocytogenes reported individually and a retrospective study of 43 cases of joint and bone listerial infection, including 34 with prosthetic joint infection, conducted in France. We have described their clinical and para-clinical features and tried to elaborate on the pathophysiology, treatment, and prevention. Prosthetic joint infection from L. monocytogenes is mainly late. Systemic inflammation may be absent. Although rare, it must be suspected in patients at high risk for both prosthetic joint and listerial infections. In addition, those patients must be instructed on appropriate preventive measures.

  14. Pannus-related prosthetic valve dysfunction. Case report.

    Science.gov (United States)

    Moldovan, Maria-Sînziana; Bedeleanu, Daniela; Kovacs, Emese; Ciumărnean, Lorena; Molnar, Adrian

    2016-01-01

    Pannus-related prosthetic valve dysfunction, a complication of mechanical prosthetic valve replacement, is rare, with a slowly progressive evolution, but it can be acute, severe, requiring surgical reintervention. We present the case of a patient with a mechanical single disc aortic prosthesis, with moderate prosthesis-patient mismatch, minor pannus found on previous ultrasound examinations, who presented to our service with angina pain with a duration of 1 hour, subsequently interpreted as non-ST segment elevation myocardial infarction (NSTEMI) syndrome. Coronarography showed normal epicardial coronary arteries, an ample movement of the prosthetic disc, without evidence of coronary thromboembolism, and Gated Single-Photon Emission Computerized Tomography (SPECT) with Technetium (Tc)-99m detected no perfusion defects. Transthoracic echocardiography (TTE) evidenced a dysfunctional prosthesis due to a subvalvular mass; transesophageal echocardiography (TOE) showed the interference of this mass, with a pannus appearance, with the closure of the prosthetic disc. Under conditions of repeated angina episodes, under anticoagulant treatment, surgery was performed, with the intraoperative confirmation of pannus and its removal. Postoperative evolution was favorable. This case reflects the diagnostic and therapeutic management problems of pannus-related prosthetic valve dysfunction.

  15. Opportunities in the electrowinning of molten titanium from titanium dioxide

    CSIR Research Space (South Africa)

    Van Vuuren, DS

    2005-10-01

    Full Text Available used, the following forms of titanium are produced: titanium sponge, sintered electrode sponge, powder, molten titanium, electroplated titanium, hydride powder, and vapor-phase depos- ited titanium. Comparing the economics of alter- native...-up for producing titanium via the Kroll process is approximately as follows: ilmenite ($0.27/kg titanium sponge); titanium slag ($0.75/kg titanium sponge); TiCl4 ($3.09/kg titanium sponge); titanium sponge raw materials costs ($5.50/kg titanium sponge); total...

  16. Passive prosthetic hands and tools: A literature review.

    Science.gov (United States)

    Maat, Bartjan; Smit, Gerwin; Plettenburg, Dick; Breedveld, Paul

    2018-02-01

    The group of passive prostheses consists of prosthetic hands and prosthetic tools. These can either be static or adjustable. Limited research and development on passive prostheses has been performed although many people use these prosthesis types. Although some publications describe passive prostheses, no recent review of the peer-reviewed literature on passive prostheses is available. Review the peer-reviewed literature on passive prostheses for replacement of the hand. Literature review. Four electronic databases were searched using a Boolean combination of relevant keywords. English-language articles relevant to the objective were selected. In all, 38 papers were included in the review. Publications on passive prosthetic hands describe their users, usage, functionality, and problems in activities of daily living. Publications on prosthetic tools mostly focus on sport, recreation, and vehicle driving. Passive hand prostheses receive little attention in prosthetic research and literature. Yet one out of three people with a limb deficiency uses this type of prosthesis. Literature indicates that passive prostheses can be improved on pulling and grasping functions. In the literature, ambiguous names are used for different types of passive prostheses. This causes confusion. We present a new and clear classification of passive prostheses. Clinical relevance This review provides information on the users of passive prosthetic hands and tools, their usage and the functionality. Passive prostheses receive very little attention and low appreciation in literature. Passive prosthetic hands and tools show to be useful to many unilateral amputees and should receive more attention and higher acceptance.

  17. Validation of the prosthetic esthetic index

    DEFF Research Database (Denmark)

    Özhayat, Esben B; Dannemand, Katrine

    2014-01-01

    OBJECTIVES: In order to diagnose impaired esthetics and evaluate treatments for these, it is crucial to evaluate all aspects of oral and prosthetic esthetics. No professionally administered index currently exists that sufficiently encompasses comprehensive prosthetic esthetics. This study aimed...... to validate a new comprehensive index, the Prosthetic Esthetic Index (PEI), for professional evaluation of esthetics in prosthodontic patients. MATERIAL AND METHODS: The content, criterion, and construct validity; the test-retest, inter-rater, and internal consistency reliability; and the sensitivity...... furthermore distinguish between participants and controls, indicating sufficient sensitivity. CONCLUSION: The PEI is considered a valid and reliable instrument involving sufficient aspects for assessment of the professionally evaluated esthetics in prosthodontic patients. CLINICAL RELEVANCE...

  18. Candida infection of a prosthetic shoulder joint

    Energy Technology Data Exchange (ETDEWEB)

    Lichtman, E.A.

    1983-09-01

    A heroin addict developed a Candida parapsilosis infection in a prosthetic shoulder joint. Radiographs showed loose fragments of cement with prosthetic loosening. The patient was treated with removal of the prosthesis and intravenous amphotericin B followed by oral ketoconazole.

  19. Candida infection of a prosthetic shoulder joint

    International Nuclear Information System (INIS)

    Lichtman, E.A.; Veterans Administration Medical Center, New York

    1983-01-01

    A heroin addict developed a Candida parapsilosis infection in a prosthetic shoulder joint. Radiographs showed loose fragments of cement with prosthetic loosening. The patient was treated with removal of the prosthesis and intravenous amphotericin B followed by oral ketoconazole. (orig.)

  20. Dose uncertainties associated with a set density override of unknown hip prosthetic composition.

    Science.gov (United States)

    Rijken, James D; Colyer, Christopher J

    2017-09-01

    The dosimetric uncertainties associated with radiotherapy through hip prostheses while overriding the implant to a set density within the TPS has not yet been reported. In this study, the uncertainty in dose within a PTV resulting from this planning choice was investigated. A set of metallic hip prosthetics (stainless steel, titanium, and two different Co-Cr-Mo alloys) were CT scanned in a water bath. Within the TPS, the prosthetic pieces were overridden to densities between 3 and 10 g/cm 3 and irradiated on a linear accelerator. Measured dose maps were compared to the TPS to determine which density was most appropriate to override each metal. This was shown to be in disagreement with the reported literature values of density which was attributed to the TPS dose calculation algorithm and total mass attenuation coefficient differences in water and metal. The dose difference was then calculated for a set density override of 6 g/cm 3 in the TPS and used to estimate the dose uncertainty beyond the prosthesis. For beams passing through an implant, the dosimetric uncertainty in regions of the PTV may be as high as 10% if the implant composition remains unknown and a set density override is used. These results highlight limitations of such assumptions and the need for careful consideration by radiation oncologist, therapist, and physics staff. © 2017 Adelaide Radiotherapy Centre. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine.

  1. Management of Prosthetic Joint Infection.

    Science.gov (United States)

    Tande, Aaron J; Gomez-Urena, Eric O; Berbari, Elie F; Osmon, Douglas R

    2017-06-01

    Although uncommon, prosthetic joint infection is a devastating complication. This challenging condition requires a coordinated management approach to achieve good patient outcomes. This review details the general principles to consider when managing patients with prosthetic joint infection. The different medical/surgical treatment strategies and how to appropriately select a strategy are discussed. The data to support each strategy are presented, along with discussion of antimicrobial strategies in specific situations. Copyright © 2017 Elsevier Inc. All rights reserved.

  2. Which prosthetic foot to prescribe?

    OpenAIRE

    De Asha, AR; Barnett, CT; Struchkov, V; Buckley, JG

    2017-01-01

    Introduction: \\ud Clinicians typically use findings from cohort studies to objectively inform judgements regarding the potential (dis)advantages of prescribing a new prosthetic device. However, before finalising prescription a clinician will typically ask a patient to 'try out' a change of prosthetic device while the patient is at the clinic. Observed differences in gait when using the new device should be the result of the device’s mechanical function, but could also conceivably be due to pa...

  3. Virtual surgical planning and 3D printing in prosthetic orbital reconstruction with percutaneous implants: a technical case report

    Directory of Open Access Journals (Sweden)

    Huang Y

    2016-10-01

    Full Text Available Yu-Hui Huang,1,2 Rosemary Seelaus,1,2 Linping Zhao,1,2 Pravin K Patel,1,2 Mimis Cohen1,2 1The Craniofacial Center, Department of Surgery, Division of Plastic & Reconstructive Surgery, University of Illinois Hospital & Health Sciences System, 2University of Illinois College of Medicine at Chicago, Chicago, IL, USA Abstract: Osseointegrated titanium implants to the cranial skeleton for retention of facial prostheses have proven to be a reliable replacement for adhesive systems. However, improper placement of the implants can jeopardize prosthetic outcomes, and long-term success of an implant-retained prosthesis. Three-dimensional (3D computer imaging, virtual planning, and 3D printing have become accepted components of the preoperative planning and design phase of treatment. Computer-aided design and computer-assisted manufacture that employ cone-beam computed tomography data offer benefits to patient treatment by contributing to greater predictability and improved treatment efficiencies with more reliable outcomes in surgical and prosthetic reconstruction. 3D printing enables transfer of the virtual surgical plan to the operating room by fabrication of surgical guides. Previous studies have shown that accuracy improves considerably with guided implantation when compared to conventional template or freehand implant placement. This clinical case report demonstrates the use of a 3D technological pathway for preoperative virtual planning through prosthesis fabrication, utilizing 3D printing, for a patient with an acquired orbital defect that was restored with an implant-retained silicone orbital prosthesis. Keywords: computer-assisted surgery, virtual surgical planning (VSP, 3D printing, orbital prosthetic reconstruction, craniofacial implants

  4. Fabrication of titanium alloy frameworks for complete dentures by selective laser melting.

    Science.gov (United States)

    Kanazawa, Manabu; Iwaki, Maiko; Minakuchi, Shunsuke; Nomura, Naoyuki

    2014-12-01

    Casting difficulties have led to the limited use of titanium in dental prostheses. The selective laser melting system was recently developed to fabricate biomedical components from titanium alloys. However, the fabrication of a titanium alloy framework for a maxillary complete denture by selective laser melting has not yet been investigated. The purpose of the study was to fabricate thin titanium alloy frameworks for a maxillary complete denture with a selective laser melting system and to evaluate their hardness and microstructure. A cast of an edentulous maxilla was scanned with a dental 3-dimensional cone-beam computed tomography system, and standard triangulation language data were produced with the DICOM Viewer (Digital Imaging and Communications in Medicine). Two types of metal frameworks for complete dentures were designed with 3-dimensional computer-aided design software. Two titanium alloy frameworks, SLM-1 and SLM-2, were fabricated from these designs with the selective laser melting system. Plate-shaped specimens were cut from the central flat region of SLM-1, SLM-2, and as-cast Ti-6Al-4V (As-cast). Vickers hardness testing, optical microscopy, and x-ray diffraction measurements were performed. Thin titanium alloy frameworks for maxillary complete dentures could be fabricated by selective laser melting. The hardness values for SLM-1 and SLM-2 were higher than that for the as-cast specimen. Optical microscopy images of the SLM-1 and SLM-2 microstructure showed that the specimens did not exhibit pores, indicating that dense frameworks were successfully obtained with the selective laser melting process. In the x-ray diffraction patterns, only peaks associated with the α phase were observed for SLM-1 and SLM-2. In addition, the lattice parameters for SLM-1 and SLM-2 were slightly larger than those for the as-cast specimen. The mechanical properties and microstructure of the denture frameworks prepared by selective laser melting indicate that these dentures

  5. Bruxism and prosthetic treatment: a critical review.

    Science.gov (United States)

    Johansson, Anders; Omar, Ridwaan; Carlsson, Gunnar E

    2011-07-01

    Based on the findings from available research on bruxism and prosthetic treatment published in the dental literature, an attempt was made to draw conclusions about the existence of a possible relationship between the two, and its clinical relevance. MEDLINE/PubMed searches were conducted using the terms 'bruxism' and 'prosthetic treatment', as well as combinations of these and related terms. The few studies judged to be relevant were critically reviewed, in addition to papers found during an additional manual search of reference lists within selected articles. Bruxism is a common parafunctional habit, occurring both during sleep and wakefulness. Usually it causes few serious effects, but can do so in some patients. The etiology is multifactorial. There is no known treatment to stop bruxism, including prosthetic treatment. The role of bruxism in the process of tooth wear is unclear, but it is not considered a major cause. As informed by the present critical review, the relationship between bruxism and prosthetic treatment is one that relates mainly to the effect of the former on the latter. Bruxism may be included among the risk factors, and is associated with increased mechanical and/or technical complications in prosthodontic rehabilitation, although it seems not to affect implant survival. When prosthetic intervention is indicated in a patient with bruxism, efforts should be made to reduce the effects of likely heavy occlusal loading on all the components that contribute to prosthetic structural integrity. Failure to do so may indicate earlier failure than is the norm. Copyright © 2011 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  6. Graft-Sparing Strategy for Thoracic Prosthetic Graft Infection.

    Science.gov (United States)

    Uchino, Gaku; Yoshida, Takeshi; Kakii, Bunpachi; Furui, Masato

    2018-04-01

     Thoracic prosthetic graft infection is a rare but serious complication with no standard management. We reported our surgical experience on graft-sparing strategy for thoracic prosthetic graft infection.  This study included patients who underwent graft-sparing surgery for thoracic prosthetic graft infection at Matsubara Tokushukai Hospital in Japan from January 2000 to October 2017.  There were 17 patients included in the analyses, with a mean age at surgery of 71.0 ± 10.5 years; 11 were men. In-hospital mortality was observed in five patients (29.4%).  Graft-sparing surgery for thoracic prosthetic graft infection is an alternative option particularly for early graft infection after hemiarch replacement. Georg Thieme Verlag KG Stuttgart · New York.

  7. On the characteristics and application of thin wall welded titanium tubes for heat transfer

    International Nuclear Information System (INIS)

    Nishimura, Takashi; Miyamoto, Yoshiyuki

    1985-01-01

    Because of the excellent corrosion resistance, thin wall welded titanium tubes have become to be used in large number as the heat transfer tubes of condensers and seawater desalting plants using seawater in place of conventional copper alloy tubes. Especially in nuclear power plants, the all titanium condensers using thin wall welded titanium tubes and titanium tube plates were adopted in the almost all plants under construction or expected to be constructed. In this report, the various characteristics of thin wall welded titanium tubes required for using them as heat transfer tubes, such as corrosion resistance, heat transfer characteristics, fatigue strength and expanding characteristics, are outlined, and the state of use is described. At first, relatively thick seamless titanium tubes were used for chemical industry, but thereafter, due to the advance of the mass production techniques, the welded titanium tubes of less than 0.7 mm thickness and high quality have become to be supplied at low cost. In 1969, titanium tubes were used for the first time in Japan for the air cooler in the condenser of Akita Power Station, Tohoku Electric Power Co., Inc. The features of titanium are small specific gravity, small linear expansion coefficient and small Young's modulus. (Kako, I.)

  8. Echocardiographic evaluation of heart valve prosthetic dysfunction

    Directory of Open Access Journals (Sweden)

    Yuriy Ivaniv

    2018-02-01

    Full Text Available Patients with replaced heart valve submitted to echocardiographic examination may have symptoms related either to valvular malfunction or ventricular dysfunction from different causes. Clinical examination is not reliable in a prosthetic valve evaluation and the main information regarding its function could be obtained using different cardiac ultrasound modalities. This review provides a description of echocardiographic and Doppler techniques useful in evaluation of prosthetic heart valves. For the interpretation of echocardiography there is a need in special knowledge of prosthesis types and possible reasons of prosthetic function deterioration. Echocardiography allows to reveal valve thrombosis, pannus formation, vegetation and such complications of infective endocarditis as valve ring abscess or dehiscence. Transthoracic echocardiography requires different section plane angles and unconventional views. Transesophageal echocardiography is more often used than in native valve examination due to better visualization of prosthetic valve structure and function. Three-dimensional echocardiography could provide more detailed visual information especially in the assessment of paravalvular regurgitation or valve obstruction.

  9. Imaging and dosimetric considerations for titanium prosthesis implanted within the irradiated region by high photon beams

    International Nuclear Information System (INIS)

    Indogo, V.

    2014-07-01

    The aim of this research was to observe dose distributions in the vicinity of titanium prosthetic implants during radiotherapy procedures. Data were obtained using a locally fabricated tissue equivalent phantom CT images, and in blue water phantom with titanium prosthesis which was irradiated with 60 Co gamma radiation and Elekta Platform photon beams. Images obtained were loaded into Prowess Panther and Oncentra treatment planning systems (TPSs) for dose simulations. Prowess TPS (1.25 MeV) estimated lesser errors whilst Oncentra (6 and 15 MV) dose simulations yielded large variations. Proximal ends of the metal recorded slight increase in doses as a rcsult of backscatter with dose increment below acceptable tolerance of ±3%. Doses measured decreases on the distal side of the prosthesis at a distance less than d max from the plate on each beam energy. Beyond certain depth along the axis, depth doses increased slightly mainly due to increase in electron fluence by portions receiving unperturbed dose. An increase in the plate thickness showed a corresponding decrease on percentage depth dose. A reduction in the above trend was also noticed with an increase in beam energy primarily because scattered photons are more forwardly directed. Prowess TPS (convolution superposition algorithm) was found to be better at reducing dose variation than OMP (collapse cone algorithm) when correction for artifact. Manual calculations on blue phantom data agree with results from Prowess. Oncentra is not capable of simulating dose around titanium prosthesis as its range of densities, 0.00121 to 2.83, excludes titanium density (rED for titanium is 3.74). (au)

  10. Prosthetic management of deciduous teeth

    OpenAIRE

    Bassil, Jean

    2015-01-01

    Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Medicina Dentária Introduction: Situations of single or multiple edentulous are not an exception during childhood. Prosthetic management is necessary in case of absence of replacing tooth or when its eruption is planned too far in time. Indications of prosthetic rehabilitation for children are multiple and rise from the etiologic factors caus...

  11. Cell Attachment Following Instrumentation with Titanium and Plastic Instruments, Diode Laser, and Titanium Brush on Titanium, Titanium-Zirconium, and Zirconia Surfaces.

    Science.gov (United States)

    Lang, Melissa S; Cerutis, D Roselyn; Miyamoto, Takanari; Nunn, Martha E

    2016-01-01

    The aim of this study was to evaluate the surface characteristics and gingival fibroblast adhesion of disks composed of implant and abutment materials following brief and repeated instrumentation with instruments commonly used in procedures for implant maintenance, stage-two implant surgery, and periimplantitis treatment. One hundred twenty disks (40 titanium, 40 titaniumzirconium, 40 zirconia) were grouped into treatment categories of instrumentation by plastic curette, titanium curette, diode microlaser, rotary titanium brush, and no treatment. Twenty strokes were applied to half of the disks in the plastic and titanium curette treatment categories, while half of the disks received 100 strokes each to simulate implant maintenance occurring on a repetitive basis. Following analysis of the disks by optical laser profilometry, disks were cultured with human gingival fibroblasts. Cell counts were conducted from scanning electron microscopy (SEM) images. Differences in surface roughness across all instruments tested for zirconia disks were negligible, while both titanium disks and titaniumzirconium disks showed large differences in surface roughness across the spectrum of instruments tested. The rotary titanium brush and the titanium curette yielded the greatest overall mean surface roughness, while the plastic curette yielded the lowest mean surface roughness. The greatest mean cell counts for each disk type were as follows: titanium disks with plastic curettes, titanium-zirconium disks with titanium curettes, and zirconia disks with the diode microlaser. Repeated instrumentation did not result in cumulative changes in surface roughness of implant materials made of titanium, titanium-zirconium, or zirconia. Instrumentation with plastic implant curettes on titanium and zirconia surfaces appeared to be more favorable than titanium implant curettes in terms of gingival fibroblast attachment on these surfaces.

  12. 100 top-cited scientific papers in limb prosthetics.

    Science.gov (United States)

    Eshraghi, Arezoo; Osman, Noor Azuan Abu; Gholizadeh, Hossein; Ali, Sadeeq; Shadgan, Babak

    2013-11-17

    Research has tremendously contributed to the developments in both practical and fundamental aspects of limb prosthetics. These advancements are reflected in scientific articles, particularly in the most cited papers. This article aimed to identify the 100 top-cited articles in the field of limb prosthetics and to investigate their main characteristics. Articles related to the field of limb prosthetics and published in the Web of Knowledge database of the Institute for Scientific Information (ISI) from the period of 1980 to 2012. The 100 most cited articles in limb prosthetics were selected based on the citation index report. All types of articles except for proceedings and letters were included in the study. The study design and level of evidence were determined using Sackett's initial rules of evidence. The level of evidence was categorized either as a systematic review or meta-analysis, randomized controlled trial, cohort study, case-control study, case series, expert opinion, or design and development. The top cited articles in prosthetics were published from 1980 to 2012 with a citation range of 11 to 90 times since publication. The mean citation rate was 24.43 (SD 16.7) times. Eighty-four percent of the articles were original publications and were most commonly prospective (76%) and case series studies (67%) that used human subjects (96%) providing level 4 evidence. Among the various fields, rehabilitation (47%), orthopedics (29%), and sport sciences (28%) were the most common fields of study. The study established that studies conducted in North America and were written in English had the highest citations. Top cited articles primarily dealt with lower limb prosthetics, specifically, on transtibial and transradial prosthetic limbs. Majority of the articles were experimental studies.

  13. Responsiveness of the Prosthetic Esthetic Scale

    DEFF Research Database (Denmark)

    Øzhayat, Esben Boeskov

    2017-01-01

    Objectives The aim of the study was to evaluate the responsiveness of the Prosthetic Esthetic Index (PEI) in a population who received prosthetic replacements. Materials and methods Fifty-seven patients who received prosthetic replacement of at least one tooth by means of fixed or removable...... prosthesis were professionally esthetically evaluated using the PEI and the Dental Aesthetic Index (DAI) before and after treatment. The participants further evaluated their oral esthetics using the Oral Health Impact Profile Aesthetic (OHIP-Aes) and Orofacial Esthetic Index (OES). Responsiveness......-Aes and OES scores. The PEI was more consistent in responsiveness than the DAI. Conclusions The PEI shows sufficient responsiveness for use in longitudinal studies and for use as a follow-up measure in clinical practice. Clinical relevance The PEI can in a standardized manner monitor and document esthetic...

  14. Stiffness and hysteresis properties of some prosthetic feet

    OpenAIRE

    van Jaarsveld, H.W.L.; Grootenboer, H.J.; de Vries, J.; Koopman, Hubertus F.J.M.

    1990-01-01

    A prosthetic foot is an important element of a prosthesis, although it is not always fully recognized that the properties of the foot, along with the prosthetic knee joint and the socket, are in part responsible for the stability and metabolic energy cost during walking. The stiffness and the hysteresis, which are the topics of this paper, are not properly prescribed, but could be adapted to improve the prosthetic walking performance. The shape is strongly related to the cosmetic appearance a...

  15. Control method for prosthetic devices

    Science.gov (United States)

    Bozeman, Richard J., Jr. (Inventor)

    1995-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the moveable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the moveable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective moveable prosthesis device and its sub-prosthesis.

  16. Tomographic and echocardiographic diagnosis of mitral prosthetic valve thrombosis

    International Nuclear Information System (INIS)

    Sainz Gonzalez de la Penna, Benito; Ramos Gutierrez, Luis Benito; Gonzalez Artiles, Iovank

    2010-01-01

    Despite the progress achieved in the design of mechanical prosthetic valves, prosthetic valve thrombosis remains a frequent cause of morbidity, usually due to incorrect anticoagulation. A patient was presented with mitral prosthetic thrombosis one year after implantation, who had been diagnosed by transthoracic transesophageal echocardiography imaging and 64-slice computed tomography. Thrombolytic therapy was successful and led to the satisfactory evolution of the patient

  17. Thoracic lateral extracavitary corpectomy for anterior column reconstruction with expandable and static titanium cages: clinical outcomes and surgical considerations in a consecutive case series.

    Science.gov (United States)

    Holland, Christopher M; Bass, David I; Gary, Matthew F; Howard, Brian M; Refai, Daniel

    2015-02-01

    Many surgical interventions have emerged as effective means of restoring mechanical stability of the anterior column of the spine. The lateral extracavitary approach (LECA) allows for broad visualization and circumferential reconstruction of the spinal column. However, early reports demonstrated significant complication rates, protracted operative times, and prolonged hospitalizations. More recent reports have highlighted concerns for subsidence, particularly with expandable cages. Our work seeks to describe a single-surgeon consecutive series of patients undergoing LECA for thoracic corpectomy. Specifically, the objective was to explore the surgical considerations, clinical and radiographic outcomes, and complication profile of this approach. A retrospective study examined data from 17 consecutive patients in whom single or multi-level corpectomy was performed via a LECA by a single surgeon. Vertebral body replacement was achieved with either a static or expandable titanium cage. The Karnofsky Performance Scale (KPS) was utilized to assess patient functional status before and after surgery. Radiographic outcomes, particularly footplate-to-body ratio and subsidence, were assessed on CT imaging at 6 weeks after surgery and at follow-up of at least 6 months. The majority of patients had post-operative KPS scores consistent with functional independence (≥70, 12/17 patients, 71%). Fourteen patients had improved or maintained function by last follow-up. In both groups, all patients had a favorable footplate-to-body ratio, and rates of subsidence were similar at both time points. Notably, the overall complication rate (24%) was significantly lower than that published in the literature, and no patient suffered a pneumothorax that required placement of a thoracostomy tube. The LECA approach for anterior column reconstruction with static or expandable cages is an important surgical consideration with favorable surgical parameters and complication rates. Further, use of

  18. Prosthetic Consideration in Implant-supported Prosthesis: A Review of Literature.

    Science.gov (United States)

    Gowd, Manga Snigdha; Shankar, Thatapudi; Ranjan, Rajeev; Singh, Arpita

    2017-06-01

    Modern dentistry has changed tremendously with implant therapy. For the successful implant therapy, making a proper treatment plan considering both surgical and prosthetic part in mind is the key of success. Often practitioners tend to create a treatment plan overlooking the basic principles of prosthetic part. This present review has discussed various prosthetic consideration of implant-supported prosthesis. A step-by-step detailed prosthetic option with their indications has been discussed to help all dental implant practitioners in making of an optimal treatment plan for each case.

  19. Clinical evaluation of immediate loading of electroeroded screw-retained titanium fixed prostheses supported by tilted implant: a multicenter retrospective study.

    Science.gov (United States)

    Acocella, Alessandro; Ercoli, Carlo; Geminiani, Alessandro; Feng, Changyong; Billi, Mauro; Acocella, Gabriele; Giannini, Domenico; Sacco, Roberto

    2012-05-01

    Immediate occlusal loading of dental implants in the edentulous mandible has proven to be an effective, reliable, and predictable treatment protocol. However, there is limited long-term data available in the literature, when an electroeroded definitive cast-titanium fixed prosthesis is used for this treatment protocol. The aim of this study was to evaluate the clinical effectiveness of dental implants (Astra Tech Dental, Mölndal, Sweden) in the edentulous mandible immediately loaded with an electroeroded cast-titanium screw-retained fixed prosthesis. Forty-five patients received five implants each in the interforaminal area. All the implants were inserted with torque up to 40 Ncm and the distal implants were distally tilted approximately 20 to 30 degrees to minimize the length of posterior cantilevers. Implants were loaded within 48 hours of placement with an acrylic resin-titanium screw-retained prosthesis fabricated by electroerosion. Two of the 225 inserted implants failed after 3 and 16 months of healing, respectively, with a cumulative survival rate of 99.1% and a prosthetic survival rate of 97.8%. Immediate loading of tilted dental implants inserted in the edentulous mandible with a screw-retained titanium definitive prosthesis fabricated with electrical discharge machining provide reliable and predictable results. © 2011 Wiley Periodicals, Inc.

  20. The role of vision processing in prosthetic vision.

    Science.gov (United States)

    Barnes, Nick; He, Xuming; McCarthy, Chris; Horne, Lachlan; Kim, Junae; Scott, Adele; Lieby, Paulette

    2012-01-01

    Prosthetic vision provides vision which is reduced in resolution and dynamic range compared to normal human vision. This comes about both due to residual damage to the visual system from the condition that caused vision loss, and due to limitations of current technology. However, even with limitations, prosthetic vision may still be able to support functional performance which is sufficient for tasks which are key to restoring independent living and quality of life. Here vision processing can play a key role, ensuring that information which is critical to the performance of key tasks is available within the capability of the available prosthetic vision. In this paper, we frame vision processing for prosthetic vision, highlight some key areas which present problems in terms of quality of life, and present examples where vision processing can help achieve better outcomes.

  1. Antithrombotic Therapy in Patients with Prosthetic Heart Valves

    Directory of Open Access Journals (Sweden)

    Mohamed HA

    2009-01-01

    Full Text Available Patients with mechanical valve prostheses require a lifelong anticoagulant treatment. The combined use of Warfarin and low-dose aspirin appears to reduce the risk of valve thrombosis and systemic embolism at a low risk of bleeding. The management of women with prosthetic heart valves during pregnancy poses a particular challenge, as there are no available controlled clinical trials to provide guidelines for effective antithrombotic therapy. Oral anticoagulants, such as Warfarin, cause foetal embryopathy; unfractionated heparin and low-molecular-weight heparin have been reported to be ineffective in preventing thromboembolic complications.This article discusses the available data and the most recent guidelines in the antithrombotic management of patients with prosthetic valves, and antithrombotic therapy in various clinical situations such as pregnant women with prosthetic heart valves, and patients with prosthetic heart valves undergoing noncardiac surgery.

  2. Amputation and Prosthetics

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Amputation and Prosthetics Email to a friend * required ...

  3. 38 CFR 17.150 - Prosthetic and similar appliances.

    Science.gov (United States)

    2010-07-01

    ... appliances. 17.150 Section 17.150 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS MEDICAL Prosthetic, Sensory, and Rehabilitative Aids § 17.150 Prosthetic and similar appliances... appliances including invalid lifts and therapeutic and rehabilitative devices, and special clothing made...

  4. Viability of Controlling Prosthetic Hand Utilizing Electroencephalograph (EEG) Dataset Signal

    Science.gov (United States)

    Miskon, Azizi; A/L Thanakodi, Suresh; Raihan Mazlan, Mohd; Mohd Haziq Azhar, Satria; Nooraya Mohd Tawil, Siti

    2016-11-01

    This project presents the development of an artificial hand controlled by Electroencephalograph (EEG) signal datasets for the prosthetic application. The EEG signal datasets were used as to improvise the way to control the prosthetic hand compared to the Electromyograph (EMG). The EMG has disadvantages to a person, who has not used the muscle for a long time and also to person with degenerative issues due to age factor. Thus, the EEG datasets found to be an alternative for EMG. The datasets used in this work were taken from Brain Computer Interface (BCI) Project. The datasets were already classified for open, close and combined movement operations. It served the purpose as an input to control the prosthetic hand by using an Interface system between Microsoft Visual Studio and Arduino. The obtained results reveal the prosthetic hand to be more efficient and faster in response to the EEG datasets with an additional LiPo (Lithium Polymer) battery attached to the prosthetic. Some limitations were also identified in terms of the hand movements, weight of the prosthetic, and the suggestions to improve were concluded in this paper. Overall, the objective of this paper were achieved when the prosthetic hand found to be feasible in operation utilizing the EEG datasets.

  5. Pre-prosthetic surgical alterations in maxillectomy to enhance the prosthetic prognoses as part of rehabilitation of oral cancer patient.

    Science.gov (United States)

    El Fattah, H; Zaghloul, A; Pedemonte, E; Escuin, T

    2012-03-01

    After maxillectomy, prosthetic restoration of the resulting defect is an essential step because it signals the beginning of patient's rehabilitation. The obturator used to restore the defect should be comfortable, restore adequate speech, deglutition, mastication, and be cosmetically acceptable, success will depend on the size and location of the defect and the quantity and integrity of the remaining structures, in addition to pre-prosthetic surgical preparation of defect site. Preoperative cooperation between the oncologist surgeon and the maxillofacial surgeon may allow obturation of a resultant defect by preservation of the premaxilla or the tuberosity on the defect side and maintaining the alveolar bone or teeth adjacent to the defect. This study evaluates the importance of pre-prosthetic surgical alterations at the time maxillectomy on the enhancement of the prosthetic prognoses as part of the rehabilitation of oral cancer patient. The study was carried out between 2003- 2008, on 66 cancer patients(41 male-25 female) age ranged from 33 to 72 years, at National Cancer Institute, Cairo University, whom underwent maxillectomy surgery to remove malignant tumor as a part of cancer treatment. Patients were divided in two groups. Group A: Resection of maxilla followed by preprosthetic surgical preparation. Twenty-four cancer patients (13 male - 11 female). Group B: Resection of maxilla without any preprosthetic surgical preparation. Forty-two cancer patients (28 male-14 female). Outcome variables measured included facial contour and aesthetic results, speech understandability, ability to eat solid foods, oronasal separation, socializing outside the home, and return-to-work status. Flap success and donor site morbidity were also studied. To improve the prosthetic restoration of maxillary defect resulting maxillary resection as part treatment of maxillofacial tumor depends on the close cooperation between prosthodontist and surgeon, by combination of pre-prosthetic

  6. TESTS METALLIC BIOMATERIALS FOR COMPUTER-AIDED DESIGN AND MANUFACTURING OF FIXED PROSTHETIC RESTORATIONS

    Directory of Open Access Journals (Sweden)

    Anna M. RYNIEWICZ

    2014-03-01

    Full Text Available A direct metal laser sintering method (DMLS is a new technology used for getting structures by the CAD/CAM procedures. The aim of the elaboration was a question of structural identification and setting strength parameters of titanium (Ticp and its alloy (Ti6Al4V which are used to serve as base for those permanent prosthetic supplements which are later manufactured with the employment of CAD/CAM systems. The research work was performed on Ticp samples – those which were intended for manufacture of structures by decrement milling working, and Ti6Al4V samples that comes from laser increment sintering of powder. According to the results obtained, the following conclusion has been derived: when strength aspect is discussed, the DMLS method is a preferred one for manufacturing of load structures in dentistry and may be an alternate way for the CAD/CAM system used in decrement processing.

  7. Rotationplasty with vascular reconstruction for prosthetic knee joint infection.

    Science.gov (United States)

    Fujiki, Masahide; Miyamoto, Shimpei; Nakatani, Fumihiko; Kawai, Akira; Sakuraba, Minoru

    2015-01-01

    Rotationplasty is used most often as a function-preserving salvage procedure after resection of sarcomas of the lower extremity; however, it is also used after infection of prosthetic knee joints. Conventional vascular management during rotationplasty is to preserve and coil major vessels, but recently, transection and reanastomosis of the major vessels has been widely performed. However, there has been little discussion regarding the optimal vascular management of rotationplasty after infection of prosthetic knee joints because rotationplasty is rarely performed for this indication. We reviewed four patients who had undergone resection of osteosarcomas of the femur, placement of a prosthetic knee joint, and rotationplasty with vascular reconstruction from 2010 to 2013. The mean interval between prosthetic joint replacement and rotationplasty was 10.4 years and the mean interval between the diagnosis of prosthesis infection and rotationplasty was 7.9 years. Rotationplasty was successful in all patients; however, in one patient, arterial thrombosis developed and necessitated urgent surgical removal and arterial reconstruction. All patients were able to walk independently with a prosthetic limb after rehabilitation. Although there is no consensus regarding the most appropriate method of vascular management during rotationplasty for revision of infected prosthetic joints, vascular transection and reanastomosis is a useful option.

  8. Control System for Prosthetic Devices

    Science.gov (United States)

    Bozeman, Richard J. (Inventor)

    1996-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that of movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the moveable body part through the full-shrg position of the moveable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the moveable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective moveable prosthesis device and its sub-prosthesis.

  9. Successful thrombolysis of aortic prosthetic valve thrombosis during ...

    African Journals Online (AJOL)

    Successful thrombolysis of aortic prosthetic valve thrombosis during first trimester of pregnancy. A Shukla, AP Raval, R Shah. Abstract. Prosthetic heart valve thrombosis during pregnancy is life-threatening. Standard surgical treatment using cardiopulmonary bypass carries high maternal and fetal complications. Here we ...

  10. Welding of Prosthetic Alloys

    Directory of Open Access Journals (Sweden)

    Wojciechowska M.

    2015-04-01

    Full Text Available This paper presents the techniques of joining metal denture elements, used in prosthetic dentistry: the traditional soldering technique with a gas burner and a new technique of welding with a laser beam; the aim of the study was to make a comparative assessment of the quality of the joints in view of the possibility of applying them in prosthetic structures. Fractographic examinations were conducted along with tensile strength and impact strength tests, and the quality of the joints was assessed compared to the solid metal. The experiments have shown that the metal elements used to make dentures, joined by the technique which employs a laser beam, have better strength properties than those achieved with a gas burner.

  11. Results of the new nitinol self-expandable stents for distal biliary structures

    NARCIS (Netherlands)

    Smits, M.; Huibregtse, K.; Tytgat, G.

    1995-01-01

    The nitinol stent is a self-expandable spiral stent made of nickel-titanium alloy. We performed a pilot study to evaluate the method of stent insertion and stent efficacy. Twenty-eight patients with irresectable malignancy had nitinol stents inserted for obstructive jaundice due to distal biliary

  12. Ten questions on prosthetic shoulder infection.

    Science.gov (United States)

    Pinder, Elizabeth M; Ong, Joshua Cy; Bale, R Stephen; Trail, Ian A

    2016-07-01

    Prosthetic shoulder infection can cause significant morbidity secondary to pain and stiffness. Symptoms may be present for years before diagnosis because clinical signs are often absent and inflammatory markers may be normal. An emerging common culprit, Propionibacterium acnes, is hard to culture and so prolonged incubation is necessary. A negative culture result does not always exclude infection and new synovial fluid biochemical markers such as α defensin are less sensitive than for lower limb arthroplasty. A structured approach is necessary when assessing patients for prosthetic shoulder joint infection. This includes history, examination, serum inflammatory markers, plain radiology and aspiration and/or biopsy. A classification for the likelihood of prosthetic shoulder infection has been described based on culture, pre-operative and intra-operative findings. Treatment options include antibiotic suppression, debridement with component retention, one-stage revision, two-stage revision and excision arthroplasty. Revision arthroplasty is associated with the best outcomes.

  13. 21 CFR 890.3025 - Prosthetic and orthotic accessory.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES PHYSICAL MEDICINE DEVICES Physical Medicine Prosthetic Devices § 890.3025... intended for medical purposes to support, protect, or aid in the use of a cast, orthosis (brace), or prosthesis. Examples of prosthetic and orthotic accessories include the following: A pelvic support band and...

  14. Undergraduate prosthetics and orthotics teaching methods: A baseline for international comparison.

    Science.gov (United States)

    Aminian, Gholamreza; O'Toole, John M; Mehraban, Afsoon Hassani

    2015-08-01

    Education of Prosthetics and Orthotics is a relatively recent professional program. While there has been some work on various teaching methods and strategies in international medical education, limited publication exists within prosthetics and orthotics. To identify the teaching and learning methods that are used in Bachelor-level prosthetics and orthotics programs that are given highest priority by expert prosthetics and orthotics instructors from regions enjoying a range of economic development. Mixed method. The study partly documented by this article utilized a mixed method approach (qualitative and quantitative methods) within which each phase provided data for other phases. It began with analysis of prosthetics and orthotics curricula documents, which was followed by a broad survey of instructors in this field and then a modified Delphi process. The expert instructors who participated in this study gave high priority to student-centered, small group methods that encourage critical thinking and may lead to lifelong learning. Instructors from more developed nations placed higher priority on student's independent acquisition of prosthetics and orthotics knowledge, particularly in clinical training. Application of student-centered approaches to prosthetics and orthotics programs may be preferred by many experts, but there appeared to be regional differences in the priority given to different teaching methods. The results of this study identify the methods of teaching that are preferred by expert prosthetics and orthotics instructors from a variety of regions. This treatment of current instructional techniques may inform instructor choice of teaching methods that impact the quality of education and improve the professional skills of students. © The International Society for Prosthetics and Orthotics 2014.

  15. Analysis of Vector Models in Quantification of Artifacts Produced by Standard Prosthetic Inlays in Cone-Beam Computed Tomography (CBCT – a Preliminary Study

    Directory of Open Access Journals (Sweden)

    Ingrid Różyło-Kalinowska

    2014-11-01

    Full Text Available Cone-beam computed tomography (CBCT is a relatively new, but highly efficient imaging method applied first in dentistry in 1998. However, the quality of the obtained slices depends among other things on artifacts generated by dental restorations as well as orthodontic and prosthetic appliances. The aim of the study was to quantify the artifacts produced by standard prosthetic inlays in CBCT images. The material consisted of 17 standard prosthetic inlays mounted in dental roots embedded in resin. The samples were examined by means of a large field of view CBCT unit, Galileos (Sirona, Germany, at 85 kV and 14 mAs. The analysis was performed using Able 3DDoctor software for data in the CT raster space as well as by means of Materialise Magics software for generated vector models (STL. The masks generated in the raster space included the area of the inlays together with image artifacts. The region of interest (ROI of the raster space is a set of voxels from a selected range of Hounsfield units (109-3071. Ceramic inlay with zirconium dioxide (Cera Post as well as epoxy resin inlay including silica fibers enriched with zirconium (Easy Post produced the most intense artifacts. The smallest image distortions were created by titanium inlays, both passive (Harald Nordin and active (Flexi Flange. Inlays containing zirconium generated the strongest artifacts, thus leading to the greatest distortions in the CBCT images. Carbon fiber inlay did not considerably affect the image quality.

  16. Rehabilitation and Prosthetic Services

    Science.gov (United States)

    ... Review Resources AT Education Blind Rehab Chiropractic Service Polytrauma/TBI Prosthetics & Sensory Aids Recreation Therapy More Health ... Military Sexual Trauma PTSD Research (MIRECC) Military Exposures Polytrauma Rehabilitation Spinal Cord Injury Telehealth Womens Health Issues ...

  17. Stiffness and hysteresis properties of some prosthetic feet

    NARCIS (Netherlands)

    van Jaarsveld, H.W.L.; Grootenboer, H.J.; de Vries, J.; Koopman, Hubertus F.J.M.

    1990-01-01

    A prosthetic foot is an important element of a prosthesis, although it is not always fully recognized that the properties of the foot, along with the prosthetic knee joint and the socket, are in part responsible for the stability and metabolic energy cost during walking. The stiffness and the

  18. Titanium ; dream new material

    International Nuclear Information System (INIS)

    Lee, Yong Tae; Kim Seung Eon; Heoon, Yong Taek; Jung, Hui Won

    2001-11-01

    The contents of this book are history of Titanium, present situation of Titanium industry, property of Titanium alloy, types of it, development of new alloy of Titanium smelting of Titanium, cast of Titanium and heat treatment of Titanium, Titanium alloy for plane, car parts, biological health care, and sport leisure and daily life, prospect, and Titanium industrial development of Titanium in China.

  19. Corrosion resistance of titanium ion implanted AZ91 magnesium alloy

    International Nuclear Information System (INIS)

    Liu Chenglong; Xin Yunchang; Tian Xiubo; Zhao, J.; Chu, Paul K.

    2007-01-01

    Degradable metal alloys constitute a new class of materials for load-bearing biomedical implants. Owing to their good mechanical properties and biocompatibility, magnesium alloys are promising in degradable prosthetic implants. The objective of this study is to improve the corrosion behavior of surgical AZ91 magnesium alloy by titanium ion implantation. The surface characteristics of the ion implanted layer in the magnesium alloys are examined. The authors' results disclose that an intermixed layer is produced and the surface oxidized films are mainly composed of titanium oxide with a lesser amount of magnesium oxide. X-ray photoelectron spectroscopy reveals that the oxide has three layers. The outer layer which is 10 nm thick is mainly composed of MgO and TiO 2 with some Mg(OH) 2 . The middle layer that is 50 nm thick comprises predominantly TiO 2 and MgO with minor contributions from MgAl 2 O 4 and TiO. The third layer from the surface is rich in metallic Mg, Ti, Al, and Ti 3 Al. The effects of Ti ion implantation on the corrosion resistance and electrochemical behavior of the magnesium alloys are investigated in simulated body fluids at 37±1 deg. C using electrochemical impedance spectroscopy and open circuit potential techniques. Compared to the unimplanted AZ91 alloy, titanium ion implantation significantly shifts the open circuit potential (OCP) to a more positive potential and improves the corrosion resistance at OCP. This phenomenon can be ascribed to the more compact surface oxide film, enhanced reoxidation on the implanted surface, as well as the increased β-Mg 12 Al 17 phase

  20. Successful Management of Prosthetic Valve Brucella Endocarditis with Antibiotherapy Alone

    Directory of Open Access Journals (Sweden)

    José Pedro Fonseca

    2018-01-01

    Full Text Available Objectives: To report a case of mechanical aortic prosthesis Brucella endocarditis successfully treated with antibiotics alone. Materials and methods: We describe a clinical case and present a review of the literature. Results: A 60-year-old female farmer with a mechanical aortic prosthetic valve presented with low back pain and fever. She was diagnosed with prosthetic valve Brucella mellitensis endocarditis and was cured with antibiotic therapy alone. Few cases of successfully treated prosthetic valve Brucella endocarditis without surgery have been reported. Conclusion: Prosthetic valve Brucella endocarditis usually requires surgical valve replacement. However, selected patients may be successfully treated with antibiotic therapy alone.

  1. Cost analysis of debridement and retention for management of prosthetic joint infection.

    Science.gov (United States)

    Peel, T N; Dowsey, M M; Buising, K L; Liew, D; Choong, P F M

    2013-02-01

    Prosthetic joint infection remains one of the most devastating complications of arthroplasty. Debridement and retention of the prosthesis is an attractive management option in carefully selected patients. Despite this, there are no data investigating the cost of this management modality for prosthetic joint infections. The aim of this case-control study was to calculate the cost associated with debridement and retention for management of prosthetic joint infection compared with primary joint replacement surgery without prosthetic joint infection. From 1 January 2008 to 30 June 2010, there were 21 prosthetic joint infections matched to 42 control patients. Controls were matched to cases according to the arthroplasty site, age and sex. Cases had a greater number of unplanned readmissions (100% vs. 7.1%; p prosthetic joint infection the total cost, including index operation and costs of management of the prosthetic joint infection, was 3.1 times the cost of primary arthoplasty; the mean cost for cases was Australian dollars (AUD) $69,414 (±29,869) compared with $22,085 (±8147) (p prosthetic joint infections will also increase, placing significant burden on the health system. Our study adds significantly to the growing body of evidence highlighting the substantial costs associated with prosthetic joint infection. © 2011 The Authors. Clinical Microbiology and Infection © 2011 European Society of Clinical Microbiology and Infectious Diseases.

  2. [Localized purpura revealing vascular prosthetic graft infection].

    Science.gov (United States)

    Boureau, A S; Lescalie, F; Cassagnau, E; Clairand, R; Connault, J

    2013-07-01

    Prosthetic graft infection after vascular reconstruction is a rare but serious complication. We report a case of infection occurring late after implantation of an iliofemoral prosthetic vascular graft. The Staphylococcus aureus infection was revealed by vascular purpura localized on the right leg 7 years after implantation of a vascular prosthesis. This case illustrates an uncommonly late clinical manifestation presenting as an acute infection 7 years after the primary operation. In this situation, the presentation differs from early infection, which generally occurs within the first four postoperative months. Diagnosis and treatment remain a difficult challenge because prosthetic graft infection is a potentially life-threatening complication. Morbidity and mortality rates are high. Here we detail specific aspects of the clinical and radiological presentation. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  3. Salmonella Typhimurium gastroenteritis leading to chronic prosthetic vascular graft infection.

    Science.gov (United States)

    Cullinan, Milo; Clarke, Michael; Dallman, Tim; Peart, Steven; Wilson, Deborah; Weiand, Daniel

    2017-08-01

    Introduction. It is estimated up to 6 % of prosthetic vascular grafts become infected. Staphylococcus aureus is predominant in early infection and coagulase-negative staphylococci are predominant in late infections. Enterobacteriaceae cause 14-40 % of prosthetic vascular graft infections. This is, to our knowledge the first reported case of Salmonella gastroenteritis causing chronic prosthetic vascular graft infection (PVGI). Case presentation. A 57 years old lady presented with signs and symptoms of prosthetic vascular graft infection. Three years earlier, she had undergone a prosthetic axillo-femoral bypass graft for critical limb ischaemia. The infected prosthetic vascular graft was removed and Salmonella Typhimurium was isolated on culture. In the intervening period, Salmonella Typhimurium was isolated from a faecal specimen, collected during an episode of acute gastroenteritis. Whole-genome sequencing (WGS) showed that the respective Salmonella Typhimurium isolates differed by only a single nucleotide polymorphism (SNP). Salmonella Typhimurium was not isolated on culture of a faecal specimen collected five days following cessation of antimicrobial therapy. Six months after removal of the prosthetic graft, the patient remains under follow-up for her peripheral vascular disease, which currently requires no further surgical intervention. Conclusion. This case has clear implications for the management of chronic PVGI. It is vital to collect high-quality surgical specimens for microbiological analysis and empirical choices of antibiotics are unlikely to cover all potential pathogens. It may also be prudent to enquire about a history of acute gastroenteritis when assessing patients presenting with chronic PVGI.

  4. Provision of Prosthetic Services Following Lower Limb Amputation in Malaysia

    Science.gov (United States)

    Arifin, Nooranida; Hasbollah, Hasif Rafidee; Hanafi, Muhammad Hafiz; Ibrahim, Al Hafiz; Rahman, Wan Afezah Wan Abdul; Aziz, Roslizawati Che

    2017-01-01

    The incidence of lower limb amputation is high across the globe and continues to be a major threat to morbidity and mortality. Consequently, the provision of high quality and effective prosthetics services have been known as an essential component for a successful rehabilitation outcome. In Malaysia, amputation prevalence has been increasing in which several main components of service delivering aspects (such as service intervention, prosthetic personnel) should be anticipated to accommodate for the increasing demand. This article highlights the hurdles experienced in providing prosthetic services in Malaysia from multiple aspects such as financial burden to acquire the prosthesis and lack of expertise to produce quality prosthesis. This paramount issues consequently justify for the urgency to carry out national level survey on the current statistics of lower limb amputation and to ascertain the available workforce to provide a quality prosthetics services. Only with accurate and current information from the national survey, strategies and policies aimed at enhancing the outcome from prosthetics services can be achieved. PMID:29386978

  5. Prosthetic Status and Prosthetic Need Among the Patients Attending Various Dental Institutes of Ahmedabad and Gandhinagar District, Gujarat

    OpenAIRE

    Shah, Vrinda R.; Shah, Darshana N.; Parmar, Chaitanya H.

    2012-01-01

    The oral health being an integral part for the healthy living, necessity of disability limitation and rehabilitation in oral health has taken a paramount role. To assess the prosthetic status and to evaluate the prosthetic needs of the patients attending various institutes of Ahmedabad and Gandhinagar district. A total of 510 (264 males and 246 females) subjects at various dental institutes were examined in the study. A survey proforma was prepared with the help of WHO oral health assessment ...

  6. Mechanical design and performance specifications of anthropomorphic prosthetic hands: a review.

    Science.gov (United States)

    Belter, Joseph T; Segil, Jacob L; Dollar, Aaron M; Weir, Richard F

    2013-01-01

    In this article, we set forth a detailed analysis of the mechanical characteristics of anthropomorphic prosthetic hands. We report on an empirical study concerning the performance of several commercially available myoelectric prosthetic hands, including the Vincent, iLimb, iLimb Pulse, Bebionic, Bebionic v2, and Michelangelo hands. We investigated the finger design and kinematics, mechanical joint coupling, and actuation methods of these commercial prosthetic hands. The empirical findings are supplemented with a compilation of published data on both commercial and prototype research prosthetic hands. We discuss numerous mechanical design parameters by referencing examples in the literature. Crucial design trade-offs are highlighted, including number of actuators and hand complexity, hand weight, and grasp force. Finally, we offer a set of rules of thumb regarding the mechanical design of anthropomorphic prosthetic hands.

  7. A dynamic model-based approach to motion and deformation tracking of prosthetic valves from biplane x-ray images.

    Science.gov (United States)

    Wagner, Martin G; Hatt, Charles R; Dunkerley, David A P; Bodart, Lindsay E; Raval, Amish N; Speidel, Michael A

    2018-04-16

    Transcatheter aortic valve replacement (TAVR) is a minimally invasive procedure in which a prosthetic heart valve is placed and expanded within a defective aortic valve. The device placement is commonly performed using two-dimensional (2D) fluoroscopic imaging. Within this work, we propose a novel technique to track the motion and deformation of the prosthetic valve in three dimensions based on biplane fluoroscopic image sequences. The tracking approach uses a parameterized point cloud model of the valve stent which can undergo rigid three-dimensional (3D) transformation and different modes of expansion. Rigid elements of the model are individually rotated and translated in three dimensions to approximate the motions of the stent. Tracking is performed using an iterative 2D-3D registration procedure which estimates the model parameters by minimizing the mean-squared image values at the positions of the forward-projected model points. Additionally, an initialization technique is proposed, which locates clusters of salient features to determine the initial position and orientation of the model. The proposed algorithms were evaluated based on simulations using a digital 4D CT phantom as well as experimentally acquired images of a prosthetic valve inside a chest phantom with anatomical background features. The target registration error was 0.12 ± 0.04 mm in the simulations and 0.64 ± 0.09 mm in the experimental data. The proposed algorithm could be used to generate 3D visualization of the prosthetic valve from two projections. In combination with soft-tissue sensitive-imaging techniques like transesophageal echocardiography, this technique could enable 3D image guidance during TAVR procedures. © 2018 American Association of Physicists in Medicine.

  8. Adaptive sports technology and biomechanics: prosthetics.

    Science.gov (United States)

    De Luigi, Arthur Jason; Cooper, Rory A

    2014-08-01

    With the technologic advances in medicine and an emphasis on maintaining physical fitness, the population of athletes with impairments is growing. It is incumbent upon health care practitioners to make every effort to inform these individuals of growing and diverse opportunities and to encourage safe exercise and athletic participation through counseling and education. Given the opportunities for participation in sports for persons with a limb deficiency, the demand for new, innovative prosthetic designs is challenging the clinical and technical expertise of the physician and prosthetist. When generating a prosthetic prescription, physicians and prosthetists should consider the needs and preferences of the athlete with limb deficiency, as well as the functional demands of the chosen sporting activity. The intent of this article is to provide information regarding the current advancements in the adaptive sports technology and biomechanics in the field of prosthetics, and to assist clinicians and their patients in facilitating participation in sporting activities. Copyright © 2014 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  9. Periprosthetic joint infection: are patients with multiple prosthetic joints at risk?

    Science.gov (United States)

    Jafari, S Mehdi; Casper, David S; Restrepo, Camilo; Zmistowski, Benjamin; Parvizi, Javad; Sharkey, Peter F

    2012-06-01

    Patients who present with a periprosthetic joint infection in a single joint may have multiple prosthetic joints. The risk of these patients developing a subsequent infection in another prosthetic joint is unknown. Our purposes were (1) to identify the risk of developing a subsequent infection in another prosthetic joint and (2) to describe the time span and organism profile to the second prosthetic infection. We retrospectively identified 55 patients with periprosthetic joint infection who had another prosthetic joint in place at the time of presentation. Of the 55 patients, 11 (20%) developed a periprosthetic joint infection in a second joint. The type of organism was the same as the first infection in 4 (36%) of 11 patients. The time to developing a second infection averaged 2.0 years (range, 0-6.9 years). Copyright © 2012 Elsevier Inc. All rights reserved.

  10. Uncemented allograft-prosthetic composite reconstruction of the proximal femur

    Directory of Open Access Journals (Sweden)

    Li Min

    2014-01-01

    Full Text Available Background: Allograft-prosthetic composite can be divided into three groups names cemented, uncemented, and partially cemented. Previous studies have mainly reported outcomes in cemented and partially cemented allograft-prosthetic composites, but have rarely focused on the uncemented allograft-prosthetic composites. The objectives of our study were to describe a surgical technique for using proximal femoral uncemented allograft-prosthetic composite and to present the radiographic and clinical results. Materials and Methods: Twelve patients who underwent uncemented allograft-prosthetic composite reconstruction of the proximal femur after bone tumor resection were retrospectively evaluated at an average followup of 24.0 months. Clinical records and radiographs were evaluated. Results: In our series, union occurred in all the patients (100%; range 5-9 months. Until the most recent followup, there were no cases with infection, nonunion of the greater trochanter, junctional bone resorption, dislocation, allergic reaction, wear of acetabulum socket, recurrence, and metastasis. But there were three periprosthetic fractures which were fixed using cerclage wire during surgery. Five cases had bone resorption in and around the greater trochanter. The average Musculoskeletal Tumor Society (MSTS score and Harris hip score (HHS were 26.2 points (range 24-29 points and 80.6 points (range 66.2-92.7 points, respectively. Conclusions: These results showed that uncemented allograft-prosthetic composite could promote bone union through compression at the host-allograft junction and is a good choice for proximal femoral resection. Although this technology has its own merits, long term outcomes are yet not validated.

  11. Prosthetic implant treatment of the edentulous maxilla with overdenture.

    Science.gov (United States)

    Inversini, M

    2006-10-01

    The literature concerning the success of prosthetic implant treatment with maxillary overdenture is reviewed, and variables affecting treatment from the implant and prosthetic standpoint are analysed. Guidelines for the fabrication of maxillary overimplants comparable to those for mandibular overimplants are still lacking, as are evidence-based prosthetic design concepts. Individual methods and techniques have been described, but evaluation standards for the outcome of maxillary prosthetic-implant treatment are lacking or individually interpreted. The biomechanics involved in the proposed system are described, together with the advantages of telescopic crowns for the retention of removable partial prosthesis supported by maxillary implants. The positive influence, in terms of long-term prognosis, of the perio-protective design of removable partial prostheses supported by maxillary overimplants is also discussed. The proposed system not only provides stability, support and retention for removable partial prostheses supported by maxillary implants, but also enables implant survival rates to be improved, both for biomechanical reasons and due to improved oral hygiene. The simplification of fabrication procedures, repair, rebasing and re-operating also reduce the cost of follow-up and improve the cost/benefit ratio. However, additional studies are needed to clarify the number and most appropriate distribution of implants, as well as the most favourable prosthetic designs for maxillary overimplants.

  12. Surgical-prosthetic treatment of large mandibular cysts

    Directory of Open Access Journals (Sweden)

    Džambas Ljubiša D.

    2003-01-01

    Full Text Available This paper presents a combined surgical-prosthetic procedure of reconstructing mandibular bone defect in a 53 year old patient, following enucleation of a mandibular cyst (Cystectomy Partsch II. After a thorough diagnostic evaluation, a surgical procedure was planned with the particular attention to the nature of the disease, patient’s condition, size and extension of the cyst, tissue loss, and the possibilities of prosthetic management of a mandibular bone defect with partial postresection dental prosthesis. It is of great importance to point to the significance of teamwork of a maxillofacial surgeon and a specialist in prosthodontics. This kind of cooperation provided very effective and less risky soft tissue, as well as bone tissue regeneration (osteogenesis. The patient’s recovery was fast, and he could return to his daily activities and work without significant changes regarding quality of life after surgery and prosthetic treatment.

  13. Prosthetics in Paediatric Dentistry

    Directory of Open Access Journals (Sweden)

    Vulićević Zoran

    2017-07-01

    Full Text Available Premature loss of teeth in children may lead to both functional and esthetic problems. Missing teeth in both anterior and posterior regions may cause malfunctions in mastication and proper pronunciation. If the missing teeth are not replaced, further complications may occur, including adjacent tooth migration, loss of alveolar bone, and irregular occlusion. Considering the sensitive nature of children, loss of teeth may cause the development of insecurities and low self esteem problems. Due to dynamic nature of growth in children and adolescents, prosthetic appliances must not hinder development of orofacial system, and must meet adequate esthetic and functional standards. Dental prosthetic appliances in paediatrics must be planned with respect to the special conditions that led to tooth loss or damage. Multi-disciplinary approach is needed, under constant supervision of paediatric dentist and orthodontist, as well as regular checkups with clinical and radiographical examinations.

  14. Prosthetic Rehabilitation in Children: An Alternative Clinical Technique

    Directory of Open Access Journals (Sweden)

    Nádia Carolina Teixeira Marques

    2013-01-01

    Full Text Available Complete and partial removable dentures have been used successfully in numerous patients with oligodontia and/or anodontia. However, there is little information in the literature regarding the principles and guidelines to prosthetic rehabilitation for growing children. This case report describes the management of a young child with oligodontia as well as the treatment planning and the prosthetic rehabilitation technique.

  15. Mesofluidic controlled robotic or prosthetic finger

    Science.gov (United States)

    Lind, Randall F; Jansen, John F; Love, Lonnie J

    2013-11-19

    A mesofluidic powered robotic and/or prosthetic finger joint includes a first finger section having at least one mesofluidic actuator in fluid communication with a first actuator, a second mesofluidic actuator in fluid communication with a second actuator and a second prosthetic finger section pivotally connected to the first finger section by a joint pivot, wherein the first actuator pivotally cooperates with the second finger to provide a first mechanical advantage relative to the joint point and wherein the second actuator pivotally cooperates with the second finger section to provide a second mechanical advantage relative to the joint point.

  16. Embodied prosthetic arm stabilizes body posture, while unembodied one perturbs it.

    Science.gov (United States)

    Imaizumi, Shu; Asai, Tomohisa; Koyama, Shinichi

    2016-10-01

    Senses of ownership (this arm belongs to me) and agency (I am controlling this arm) originate from sensorimotor system. External objects can be integrated into the sensorimotor system following long-term use, and recognized as one's own body. We examined how an (un)embodied prosthetic arm modulates whole-body control, and assessed the components of prosthetic embodiment. Nine unilateral upper-limb amputees participated. Four frequently used their prosthetic arm, while the others rarely did. Their postural sway was measured during quiet standing with or without their prosthesis. The frequent users showed greater sway when they removed the prosthesis, while the rare users showed greater sway when they fitted the prosthesis. Frequent users reported greater everyday feelings of postural stabilization by prosthesis and a larger sense of agency over the prosthesis. We suggest that a prosthetic arm maintains or perturbs postural control, depending on the prosthetic embodiment, which involves sense of agency rather than ownership. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Sealing glasses for titanium and titanium alloys

    Science.gov (United States)

    Brow, Richard K.; McCollister, Howard L.; Phifer, Carol C.; Day, Delbert E.

    1997-01-01

    Barium lanthanoborate sealing-glass compositions are provided comprising various combinations (in terms of mole-%) of boron oxide (B.sub.2 O.sub.3), barium oxide (BaO), lanthanum oxide (La.sub.2 O.sub.3), and at least one other oxide selected from the group consisting of aluminum oxide (Al.sub.2 O.sub.3), calcium oxide (CaO), lithium oxide (Li.sub.2 O), sodium oxide (Na.sub.2 O), silicon dioxide (SiO.sub.2), or titanium dioxide (TiO.sub.2). These sealing-glass compositions are useful for forming hermetic glass-to-metal seals with titanium and titanium alloys having an improved aqueous durability and favorable sealing characteristics. Examples of the sealing-glass compositions are provided having coefficients of thermal expansion about that of titanium or titanium alloys, and with sealing temperatures less than about 900.degree. C., and generally about 700.degree.-800.degree. C. The barium lanthanoborate sealing-glass compositions are useful for components and devices requiring prolonged exposure to moisture or water, and for implanted biomedical devices (e.g. batteries, pacemakers, defibrillators, pumps).

  18. Fixed prosthetic treatment in patients with cleft lip and palate

    Directory of Open Access Journals (Sweden)

    Bajevska Jagoda

    2017-01-01

    Full Text Available Introduction. The prosthetic treatment of patients with cleft palate includes various treatment options such as fixed partial dentures, removable partial prosthesis, etc. The type of prosthetic appliance is determined by the oral health of each individual and the circumstances. We presented three adult patients with the cleft lip and palate subjected to prosthetic treatment. Case report. From the possible prosthetic solutions according to the conditions in the oral cavity and the circumstances, fixed partial dentures veneered with composite or ceramic were chosen. A proper relationship between the teeth was reached with the fixed partial dentures, and function established, the phonetics improved and satisfying aesthetics effect accomplished improving the profile appearance of the patient’s face. Plastic surgery of the nose was performed after that. Conclusion. Multidisclipinary treatment is necessary for favourable long-term outcome in cleft lip and palate patients.

  19. Repair of large abdominal wall defects with expanded polytetrafluoroethylene (PTFE).

    Science.gov (United States)

    Bauer, J J; Salky, B A; Gelernt, I M; Kreel, I

    1987-01-01

    Most abdominal wall incisional hernias can be repaired by primary closure. However, where the defect is large or there is tension on the closure, the use of a prosthetic material is indicated. Expanded polytetrafluoroethylene (PTFE) patches were used to repair incisional hernias in 28 patients between November 1983 and December 1986. Twelve of these patients (43%) had a prior failure of a primary repair. Reherniation occurred in three patients (10.7%). Wound infections developed in two patients (7.1%), both of whom had existing intestinal stomas, one with an intercurrent pelvic abscess. The prosthetic patch was removed in the patient with the abscess, but the infection was resolved in the other without sequelae. Septic complications did not occur after any operations performed in uncontaminated fields. None of the patients exhibited any undue discomfort, wound pain, erythema, or induration. Complications related to adhesions, erosion of the patch material into the viscera, bowel obstruction, or fistula formation did not occur. Based on this clinical experience, the authors believe that the PTFE patch appears to represent an advance in synthetic abdominal wall substitutes. Images Fig. 1. Fig. 2(left)., Fig. 3(right). PMID:3689012

  20. Prosthetic Mitral Valve Leaflet Escape

    Science.gov (United States)

    Kim, Darae; Hun, Sin Sang; Cho, In-Jeong; Shim, Chi-Young; Ha, Jong-Won; Chung, Namsik; Ju, Hyun Chul; Sohn, Jang Won

    2013-01-01

    Leaflet escape of prosthetic valve is rare but potentially life threatening. It is essential to make timely diagnosis in order to avoid mortality. Transesophageal echocardiography and cinefluoroscopy is usually diagnostic and the location of the missing leaflet can be identified by computed tomography (CT). Emergent surgical correction is mandatory. We report a case of fractured escape of Edward-Duromedics mitral valve 27 years after the surgery. The patient presented with symptoms of acute decompensated heart failure and cardiogenic shock. She was instantly intubated and mechanically ventilated. After prompt evaluation including transthoracic echocardiography and CT, the escape of the leaflet was confirmed. The patient underwent emergent surgery for replacement of the damaged prosthetic valves immediately. Eleven days after the surgery, the dislodged leaflet in iliac artery was removed safely and the patient recovered well. PMID:23837121

  1. Surface modification of titanium and titanium alloys by ion implantation.

    Science.gov (United States)

    Rautray, Tapash R; Narayanan, R; Kwon, Tae-Yub; Kim, Kyo-Han

    2010-05-01

    Titanium and titanium alloys are widely used in biomedical devices and components, especially as hard tissue replacements as well as in cardiac and cardiovascular applications, because of their desirable properties, such as relatively low modulus, good fatigue strength, formability, machinability, corrosion resistance, and biocompatibility. However, titanium and its alloys cannot meet all of the clinical requirements. Therefore, to improve the biological, chemical, and mechanical properties, surface modification is often performed. In view of this, the current review casts new light on surface modification of titanium and titanium alloys by ion beam implantation. (c) 2010 Wiley Periodicals, Inc.

  2. Adapting to change: influence of a microprocessor-controlled prosthetic knee on gait adaptations

    NARCIS (Netherlands)

    Prinsen, Erik Christiaan

    2016-01-01

    Advancement in prosthetic knee design have led to the introduction of microprocessor-controlled prosthetic knees (MPKs). MPKs incorporate sensors that are able to measure prosthetic loading, the knee angle, and knee angular velocity. Based on the sensor information, MPKs determine the optimal level

  3. Gentamicin-Eluting Titanium Dioxide Nanotubes Grown on the Ultrafine-Grained Titanium.

    Science.gov (United States)

    Nemati, Sima Hashemi; Hadjizadeh, Afra

    2017-08-01

    Titanium (Ti)-based materials is the most appropriate choices for the applications as orthopedic and dental implants. In this regard, ultrafine-grained (UFG) titanium with an enhanced mechanical properties and surface energy has attracted more attention. Titanium dioxide (TiO 2 ) nanotubes grown on the titanium could enhance bone bonding, cellular response and are good reservoirs for loading drugs and antibacterial agents. This article investigates gentamicin loading into and release from the TiO 2 nanotubes, grown on the UFG compared to coarse-grained (CG) titanium substrate surfaces. Equal Channel Angular Pressing (ECAP) was employed to produce the UFG structure titanium. TiO 2 nanotubes were grown by the anodizing technique on both UFG and CG titanium substrate surfaces. Scanning electron microscopy (SEM) imaging confirmed TiO 2 nanotube growth on the surface. The UV-vis spectroscopy analysis results show that the amount of gentamicin load-release in the anodized UFG titanium sample is higher than that of CG one which can be explained in terms of thicker TiO 2 nanotube arrays layer formed on UFG sample. Moreover, the anodized UFG titanium samples released the drug in a longer time than CG (1 day for the UFG titanium vs. 3 h for the CG one). Regarding wettability analysis, anodized UFG titanium sample showed more enhanced hydrophilicity than CG counterpart. Therefore, the significantly smaller grain size of pure titanium provided by the ECAP technique coupled with appropriate subsequent anodization treatment not only offers a good combination of biocompatibility and adequate mechanical properties but also it provides a delayed release condition for gentamicin.

  4. Fatigue limits of titanium-bar joints made with the laser and the electric resistance welding techniques: microstructural characterization and hardness properties.

    Science.gov (United States)

    Degidi, Marco; Nardi, Diego; Morri, Alessandro; Sighinolfi, Gianluca; Tebbel, Florian; Marchetti, Claudio

    2017-09-01

    Fatigue behavior of the titanium bars is of utmost importance for the safe and reliable operation of dental implants and prosthetic constructions based on these implants. To date, however, only few data are available on the fatigue strength of dental prostheses made with electric resistance welding and laser welding techniques. This in-vitro study highlighted that although the joints made with the laser welding approach are credited of a superior tensile strength, joints made with electric resistance welding exhibited double the minimum fatigue strength with respect to the joints made with laser welding (120 vs 60 N).

  5. Development of a 3D-Printed Robotic Prosthetic Arm

    Energy Technology Data Exchange (ETDEWEB)

    Gomez Martinez, M.; Garcia-Miquel, A.; Vidal Martinez, N.

    2016-07-01

    Current prostheses are not affordable to the general public. 3D printing technology may allow low-cost production of such devices, making them more readily accessible to people in need. This contribution presents the set-up and the considerations that have to be taken into account to develop a functional artificial upper limb prototype. The robotic prosthetic arm reported herein was produced entirely using 3D printing technology to demonstrate its feasibility on a limited budget. The project was developed to integrate two different functional modes: a prosthetic application and a remote application. The prosthetic application is intended to emulate existing prosthetic devices using myoelectric sensors. The remote application is conceived as a tool for prevention, by providing the general public with a device that could carry out activities that entail a risk of severe physical injury. This is achieved using a hand-tracking system that allows the robotic arm to copy the user’s movements remotely and in real time. The outcome of the validation tests has been considerably successful for both applications and the total costs are on target. (Author)

  6. Investigation of morphology and bioactive properties of composite coating of HA/vinyl acetate on pure titanium

    International Nuclear Information System (INIS)

    Afshar, Abdollahe; Yousefpour, Mardali; Xiudong, Yang; Li Xudong; Yang Bangcheng; Wu Yao; Chen Jiyong; Zhang Xingdong

    2006-01-01

    Electrochemical co-deposition approach was expanded to prepare composite bio-ceramic coating of hydroxyapatite (HA)/polyvinyl acetate on the surface of titanium. The role is to improve the bioactive and crystallization properties. The results of XRD, XPS, SEM and TEM characterization showed that by increasing amount of vinyl acetate in the composite bio-ceramic coating before and after immersing in the simulated body fluid (SBF), an oriented growth of HA planes on the (0 0 2) direction had been observed on titanium substrate. Also significant surface morphology changes were obtained

  7. Image segmentation for enhancing symbol recognition in prosthetic vision.

    Science.gov (United States)

    Horne, Lachlan; Barnes, Nick; McCarthy, Chris; He, Xuming

    2012-01-01

    Current and near-term implantable prosthetic vision systems offer the potential to restore some visual function, but suffer from poor resolution and dynamic range of induced phosphenes. This can make it difficult for users of prosthetic vision systems to identify symbolic information (such as signs) except in controlled conditions. Using image segmentation techniques from computer vision, we show it is possible to improve the clarity of such symbolic information for users of prosthetic vision implants in uncontrolled conditions. We use image segmentation to automatically divide a natural image into regions, and using a fixation point controlled by the user, select a region to phosphenize. This technique improves the apparent contrast and clarity of symbolic information over traditional phosphenization approaches.

  8. Implant salvage in breast reconstruction with severe peri-prosthetic infection.

    Science.gov (United States)

    Meybodi, Farid; Sedaghat, Negin; French, James; Keighley, Caitlin; Mitchell, David; Elder, Elisabeth

    2017-12-01

    Although treatment of mild peri-prosthetic infection in implant-based breast reconstruction results in high rates of resolution, successful management of severe peri-prosthetic infection remains a significant challenge. In this case series, a protocol utilizing a novel dressing - negative pressure wound therapy with instillation (NPWTi) - for the management of severe peri-prosthetic infection in breast reconstruction patients is described. This is an operative technique involving: (i) explantation of the breast prosthesis and application of the NPWTi dressing to the implant pocket; (ii) change of the NPWTi dressing; (iii) intraoperative fluid/tissue cultures; and (iv) reimplantation of the breast prosthesis when cultures yield no growth. This protocol was utilized in six cases of severe peri-prosthetic infection in five patients with immediate breast reconstruction for breast cancer or risk-reducing surgery. Cultures of fluid/tissue grew typical and/or unusual organisms. Only one case did not yield an organism. The hospital length of stay upon completion of the protocol ranged from 7-16 days (mean, 12 days). Successful implant salvage was achieved in five of six cases. The protocol was aborted in one case to allow for completion of adjuvant chemotherapy. Early findings from this case series suggest that in cases of severe peri-prosthetic infection this novel operative protocol may result in successful implant salvage for breast reconstruction patients. Further studies are needed to more fully elaborate the role of NPWTi to achieve implant salvage in challenging cases of peri-prosthetic infection. © 2015 Royal Australasian College of Surgeons.

  9. Development of novel 3D-printed robotic prosthetic for transradial amputees.

    Science.gov (United States)

    Gretsch, Kendall F; Lather, Henry D; Peddada, Kranti V; Deeken, Corey R; Wall, Lindley B; Goldfarb, Charles A

    2016-06-01

    Upper extremity myoelectric prostheses are expensive. The Robohand demonstrated that three-dimensional printing reduces the cost of a prosthetic extremity. The goal of this project was to develop a novel, inexpensive three-dimensional printed prosthesis to address limitations of the Robohand. The prosthesis was designed for patients with transradial limb amputation. It is shoulder-controlled and externally powered with an anthropomorphic terminal device. The user can open and close all five fingers, and move the thumb independently. The estimated cost is US$300. After testing on a patient with a traumatic transradial amputation, several advantages were noted. The independent thumb movement facilitated object grasp, the device weighed less than most externally powered prostheses, and the size was easily scalable. Limitations of the new prosthetic include low grip strength and decreased durability compared to passive prosthetics. Most children with a transradial congenital or traumatic amputation do not use a prosthetic. A three-dimensional printed shoulder-controlled robotic prosthesis provides a cost effective, easily sized and highly functional option which has been previously unavailable. © The International Society for Prosthetics and Orthotics 2015.

  10. Prosthetic prescription in the Netherlands: An interview with clinical experts

    NARCIS (Netherlands)

    Van Der Linde, H.; Geertzen, J.H.B.; Hofstad, C.J.; Van Limbeek, Jacques; Postema, K.

    2004-01-01

    In the process of guideline development for prosthetic prescription in the Netherlands the authors made a study of the daily clinical practice of lower limb prosthetics. Besides the evidence-based knowledge from literature the more implicit knowledge from clinical experts is of importance for

  11. PLANNING OF IMPLANTO‐PROSTHETIC STRUCTURES IN TOTAL EDENTATION ACCORDING TO BIOMECHANICAL CRITERIA

    Directory of Open Access Journals (Sweden)

    N. VASILE

    2013-07-01

    Full Text Available Scope of the study: Analysis of the biomechanical aspects of the implanto‐prosthetic structures for planning the treatment in cases of total edentation.Materials and method: The study was performed in the Clinics of Prosthetics and Oral Implantology, Military Emergency Hospital of Sibiu, on a group of mandibularly totally edentated patients. Planning of the implanto‐pros‐ thetic treatment had in view the peculiarities of total man‐ dibular edentation and observance of the biomechanical principles. Selection of the type of occlusion restoration considered the presence of parafunctions and the nature of the antagonistic arch. Special attention was paid to the direction and intensity of the forces acting in the region of the future prosthetic work. When bruxism was manifested, its preimplantary removal was compulsory.Results and discussion: In fixed prosthetic restaurati‐ ons applied on implants, distribuition of forces obviously depend on the quality of osteo‐acceptance, as well, and also on the elasticity degree of the prosthetic work. In the case of mobilized prosthetic restorations supported on implants, rigidization of implants from the anterior region of the mandible may be obtained by means of a bar. In decreasing order of their elasticity, the materials employed are: acrylate, composites, noble and seminoble alloys, other metals, ceramics. Ceramics confers maximum stability to implants, yet without redeeming the forces. For amortizing the forces and for a progressive charging of the implants, it is recommended that the first (temporary prosthetic restorations should be made of either acrylate or compo‐ sites.Conclusions. Observance of the occlusological princi‐ ples in cases of occlusal reconstruction represents the determining element which assures the osteo‐acceptance of implants and the integrity of prosthetic restaurations.

  12. Myoelectric control of prosthetic hands: state-of-the-art review

    Directory of Open Access Journals (Sweden)

    Geethanjali P

    2016-07-01

    Full Text Available Purushothaman Geethanjali School of Electrical Engineering Department of Control and Automation VIT University, Vellore, Tamil Nadu, India Abstract: Myoelectric signals (MES have been used in various applications, in particular, for identification of user intention to potentially control assistive devices for amputees, orthotic devices, and exoskeleton in order to augment capability of the user. MES are also used to estimate force and, hence, torque to actuate the assistive device. The application of MES is not limited to assistive devices, and they also find potential applications in teleoperation of robots, haptic devices, virtual reality, and so on. The myoelectric control-based prosthetic hand aids to restore activities of daily living of amputees in order to improve the self-esteem of the user. All myoelectric control-based prosthetic hands may not have similar operations and exhibit variation in sensing input, deciphering the signals, and actuating prosthetic hand. Researchers are focusing on improving the functionality of prosthetic hand in order to suit the user requirement with the different operating features. The myoelectric control differs in operation to accommodate various external factors. This article reviews the state of the art of myoelectric prosthetic hand, giving description of each control strategy. Keywords: EMG, assistive device, amputee, myoelectric control, electric powered, body ­powered, bioelectric signal control

  13. Effects of a flat prosthetic foot rocker section on balance and mobility.

    Science.gov (United States)

    Hansen, Andrew; Nickel, Eric; Medvec, Joseph; Brielmaier, Steven; Pike, Alvin; Weber, Marilyn

    2014-01-01

    Previous studies have shown that the effective rocker shape of the physiologic ankle-foot system during standing and fore-aft swaying is much flatter than that used during walking, which indicates a more stable base of support for the standing/swaying activity. Previous work suggests that flat regions within the effective rocker shapes of prosthetic ankle-foot systems could provide enhanced stability for standing balance tasks. An experimental prosthetic foot was altered to provide three different flat region lengths within its effective rocker shape. It was hypothesized that longer flat regions of the effective rocker shape would lead to improved standing balance outcomes and reduced walking performance for unilateral transtibial prosthesis users. However, no significant changes were seen in the balance and mobility outcomes of 12 unilateral transtibial prosthesis users when using the three prosthetic foot conditions. Subjects in the study significantly preferred prosthetic feet with relatively low to moderate flat regions over those with long flat regions. All the subjects without loss of light touch or vibratory sensation selected the prosthetic foot with the shortest flat region. More work is needed to investigate the effects of prosthetic foot properties on balance and mobility of prosthesis users.

  14. Vascular complications of prosthetic inter-vertebral discs.

    Science.gov (United States)

    Daly, Kevin J; Ross, E Raymond S; Norris, Heather; McCollum, Charles N

    2006-10-01

    Five consecutive cases of prosthetic inter-vertebral disc displacement with severe vascular complications on revisional surgery are described. The objective of this case report is to warn spinal surgeons that major vascular complications are likely with anterior displacement of inter-vertebral discs. We have not been able to find a previous report on vascular complications associated with anterior displacement of prosthetic inter-vertebral discs. In all five patients the prosthetic disc had eroded into the bifurcation of the inferior vena cava and the left common iliac vein. In three cases the aortic bifurcation was also involved. The fibrosis was so severe that dissecting out the arteries and veins to provide access to the relevant disc proved impossible. Formal division of the left common iliac vein and artery with subsequent repair was our solution. Anterior inter-vertebral disc displacement was associated with severe vascular injury. Preventing anterior disc displacement is essential in disc design. In the event of anterior displacement, disc removal should be planned with a Vascular Surgeon.

  15. Initial Clinical Evaluation of the Modular Prosthetic Limb

    Directory of Open Access Journals (Sweden)

    Briana N. Perry

    2018-03-01

    Full Text Available The Modular Prosthetic Limb (MPL was examined for its feasibility and usability as an advanced, dexterous upper extremity prosthesis with surface electromyography (sEMG control in with two individuals with below-elbow amputations. Compared to currently marketed prostheses, the MPL has a greater number of sequential and simultaneous degrees of motion, as well as wrist modularity, haptic feedback, and individual digit control. The MPL was successfully fit to a 33-year-old with a trans-radial amputation (TR01 and a 30-year-old with a wrist disarticulation amputation (TR02. To preserve anatomical limb length, we adjusted the powered degrees of freedom of wrist motion between users. Motor training began with practicing sEMG and pattern recognition control within the virtual integration environment (VIE. Prosthetic training sessions then allowed participants to complete a variety of activities of daily living with the MPL. Training and Motion Control Accuracy scores quantified their ability to consistently train and execute unique muscle-to-motion contraction patterns. Each user also completed one prosthetic functional metric—the Southampton Hand Assessment Procedure (SHAP for TR01 and the Jebsen-Taylor Hand Function Test (JHFT for TR02. Haptic feedback capabilities were integrated for TR01. TR01 achieved 95% accuracy at 84% of his VIE sessions. He demonstrated improved scores over a year of prosthetic training sessions, ultimately achieving simultaneous control of 13 of the 17 (76% attempted motions. His performance on the SHAP improved from baseline to final assessment with an increase in number of tasks achieved. TR01 also used vibrotactile sensors to successfully discriminate between hard and soft objects being grasped by the MPL hand. TR02 demonstrated 95% accuracy at 79% of his VIE sessions. He demonstrated improved scores over months of prosthetic training sessions, however there was a significant drop in scores initially following a mid

  16. Structural Integration and Control of Peerless Human-like Prosthetic Hand

    Science.gov (United States)

    Dave, Ankit; Muthu, P.; Karthikraj, V.; Latha, S.

    2018-04-01

    Limb damage can create severe disturbance in movement and operative abilities wherein the prosthetic rehabilitation has the potential to replace function and enhance the quality of life. This paper presents a humanlike prosthetic hand using such unique design concept of hand model using artificial bones, ligaments, and tendons controlled using Arduino. Amongst various platforms available, Arduino is known for its adaptability, adoration and low cost. The design of prosthetic hand has a unique structure with all carpal, metacarpal, and phalanges which are bones of the hand. These bones are attached to each other following the pattern of human hand using the polymeric rubber as a functioning ligament. Furthermore, this structure of finger is driven by tendons attached to all fingers and passes through the ligaments working as pulley resulting in more degrees of freedom. The motor can twitch the tendons to achieve the action of fingers. Thus the servos, controlled by an Arduino, are used to regulate the movement mechanism of the prosthetic hand.

  17. Control system and method for prosthetic devices

    Science.gov (United States)

    Bozeman, Richard J., Jr. (Inventor)

    1992-01-01

    A control system and method for prosthetic devices is provided. The control system comprises a transducer for receiving movement from a body part for generating a sensing signal associated with that movement. The sensing signal is processed by a linearizer for linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part. The linearized sensing signal is normalized to be a function of the entire range of body part movement from the no-shrug position of the movable body part through the full-shrug position of the movable body part. The normalized signal is divided into a plurality of discrete command signals. The discrete command signals are used by typical converter devices which are in operational association with the prosthetic device. The converter device uses the discrete command signals for driving the movable portions of the prosthetic device and its sub-prosthesis. The method for controlling a prosthetic device associated with the present invention comprises the steps of receiving the movement from the body part, generating a sensing signal in association with the movement of the body part, linearizing the sensing signal to be a linear function of the magnitude of the distance moved by the body part, normalizing the linear signal to be a function of the entire range of the body part movement, dividing the normalized signal into a plurality of discrete command signals, and implementing the plurality of discrete command signals for driving the respective movable prosthesis device and its sub-prosthesis.

  18. Custom CAD-CAM healing abutment and impression coping milled from a poly(methyl methacrylate) block and bonded to a titanium insert.

    Science.gov (United States)

    Proussaefs, Periklis

    2016-11-01

    This article describes a technique in which a custom-made computer-aided design and computer-aided manufacturing (CAD-CAM) healing abutment milled from a poly(methyl methacrylate) (PMMA) block is fabricated and bonded to a titanium metal insert. An impression is made during dental implant surgery, and the CAD-CAM custom-made healing abutment is fabricated before second-stage surgery while appropriate healing time is allowed for the dental implant to osseointegrate. The contours of the healing abutment are based on the contours of a tentatively designed definitive prosthesis. The healing tissue obtains contours that will be compatible with the contours of the definitive prosthesis. After the milling process is complete, a titanium metal insert is bonded to the healing abutment. Placement of the custom-made CAD-CAM healing abutment at second-stage surgery allows the tissue to obtain contours similar to those of the definitive prosthesis. A custom-made CAD-CAM impression coping milled from a PMMA block and with a titanium insert is used for the definitive impression after the soft tissue has healed. This technique allows guided soft tissue healing by using a custom-made CAD-CAM healing abutment and impression coping. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  19. Ionic implantation by plasma in titanium and stainless steels used in prosthesis and medical instruments

    International Nuclear Information System (INIS)

    Munoz C, A. E.

    2008-01-01

    A study of a process known as plasma immersion ion implantation (PIII) of nitrogen at low voltages (< 4 kV) into three kind of samples: 1) austenitic stainless AISI 316-L steel plates, 2) ferritic stainless AISI 434 steel-based dentistry drills and 3) commercially pure titanium (CPTi) disks. On the case of CPTi the study was conducted in nitrogen- oxygen calibrated mixtures: 90% N-10% O, 80% N-20% O, 70% N-30% O and in 99.5% pure oxygen and 99.9% pure nitrogen. The PIII process was carried out by using a direct current plasma source controlled both in voltage and current, a negative voltage pulse modulator, a stainless AISI 304 steel vacuum chamber and a rod of the same material, horizontally located in the upper region of the chamber, which plays the role of anode in the plasma discharge. The purpose of the nitriding is forming a relatively thick layer on the surface of the steel specimens in order to enhance their both microhardness and general corrosion performances, desirable in medical applications. This layer contains interstitial nitrogen atoms (∼24% at.) which gives place to a deformed lattice (expanded phase) of the steel. Vickers microhardness and potentiodynamic tests (the latter in agreement to the norm ASTM G-61-89) confirm an increase of microhardness up to three times and a decrease of general corrosion rate in one order of magnitude. The nitriding of de dentistry drills is aimed at inhibiting the pitting corrosion produced by the asepsis process which results in pit nucleations, their propagation and consequent fractures when being under cyclic stress (fatigue). Scanning electron microscope micrographs reveal the risks involved in surpassing the critical treatment simple temperature of 450 C as the PIII process itself induces pitting. On its part, cyclic (ASTM G-61) potentiodynamic tests indicate an excellent pitting corrosion resistance of the samples treated under 450 C. In turn, the treatment of CPTi was meant to develop oxidized and

  20. Marginal adaptation of four inlay casting waxes on stone, titanium, and zirconia dies.

    Science.gov (United States)

    Michalakis, Konstantinos X; Kapsampeli, Vassiliki; Kitsou, Aikaterini; Kirmanidou, Yvone; Fotiou, Anna; Pissiotis, Argirios L; Calvani, Pasquale Lino; Hirayama, Hiroshi; Kudara, Yukio

    2014-07-01

    between the marginal accuracy and the contact angle values. As the contact angle value became smaller, the marginal accuracy improved. All combinations of waxes and stone and titanium dies presented a high wettability. Copyright © 2014 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  1. A computational method for comparing the behavior and possible failure of prosthetic implants

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, C.; Hollerbach, K.; Perfect, S.; Underhill, K.

    1995-05-01

    Prosthetic joint implants currently in use exhibit high Realistic computer modeling of prosthetic implants provides an opportunity for orthopedic biomechanics researchers and physicians to understand possible in vivo failure modes, without having to resort to lengthy and costly clinical trials. The research presented here is part of a larger effort to develop realistic models of implanted joint prostheses. The example used here is the thumb carpo-metacarpal (cmc) joint. The work, however, can be applied to any other human joints for which prosthetic implants have been designed. Preliminary results of prosthetic joint loading, without surrounding human tissue (i.e., simulating conditions under which the prosthetic joint has not yet been implanted into the human joint), are presented, based on a three-dimensional, nonlinear finite element analysis of three different joint implant designs.

  2. Gonococcal Prosthetic Joint Infection.

    Science.gov (United States)

    Gassiep, Ian; Gilpin, Bradley; Douglas, Joel; Siebert, David

    2017-01-01

    Neisseria gonorrhoea is a common sexually transmitted infection worldwide. Disseminated gonococcal infection is an infrequent presentation and rarely can be associated with septic arthritis. Incidence of this infection is rising, both internationally and in older age groups. We present the first documented case of N. gonorrhoea prosthetic joint infection which was successfully treated with laparoscopic debridement and antimicrobial therapy.

  3. Rehand: Realistic electric prosthetic hand created with a 3D printer.

    Science.gov (United States)

    Yoshikawa, Masahiro; Sato, Ryo; Higashihara, Takanori; Ogasawara, Tsukasa; Kawashima, Noritaka

    2015-01-01

    Myoelectric prosthetic hands provide an appearance with five fingers and a grasping function to forearm amputees. However, they have problems in weight, appearance, and cost. This paper reports on the Rehand, a realistic electric prosthetic hand created with a 3D printer. It provides a realistic appearance that is same as the cosmetic prosthetic hand and a grasping function. A simple link mechanism with one linear actuator for grasping and 3D printed parts achieve low cost, light weight, and ease of maintenance. An operating system based on a distance sensor provides a natural operability equivalent to the myoelectric control system. A supporter socket allows them to wear the prosthetic hand easily. An evaluation using the Southampton Hand Assessment Procedure (SHAP) demonstrated that an amputee was able to operate various objects and do everyday activities with the Rehand.

  4. Vent-induced prosthetic leaflet thrombosis treated by open-heart valve-in-valve implantation.

    Science.gov (United States)

    Stamm, Christof; Pasic, Miralem; Buz, Semih; Hetzer, Roland

    2015-09-01

    A patient required emergency mitral valve replacement and extracorporeal membrane oxygenation (ECMO) support for acute biventricular failure. The left ventricular (LV) vent inserted via the left upper pulmonary vein induced thrombotic immobilization of a prosthetic valve leaflet, with significant intra-prosthesis regurgitation after ECMO explantation. Therefore, the left atrium was opened on the beating heart during conventional extracorporeal circulation, all prosthesis leaflets were excised and a 29-mm expandable Edwards Sapien prosthesis was inserted within the scaffold of the original prosthesis under direct vision. This case illustrates the benefits and potential problems of LV venting on ECMO support, and a rapid and safe way of replacing the prosthesis leaflets in a critical situation. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  5. Titanium metal: extraction to application

    Energy Technology Data Exchange (ETDEWEB)

    Gambogi, Joseph (USGS, Reston, VA); Gerdemann, Stephen J.

    2002-09-01

    In 1998, approximately 57,000 tons of titanium metal was consumed in the form of mill products (1). Only about 5% of the 4 million tons of titanium minerals consumed each year is used to produce titanium metal, with the remainder primarily used to produce titanium dioxide pigment. Titanium metal production is primarily based on the direct chlorination of rutile to produce titanium tetrachloride, which is then reduced to metal using the Kroll magnesium reduction process. The use of titanium is tied to its high strength-to-weight ratio and corrosion resistance. Aerospace is the largest application for titanium. In this paper, we discuss all aspects of the titanium industry from ore deposits through extraction to present and future applications. The methods of both primary (mining of ore, extraction, and purification) and secondary (forming and machining) operations will be analyzed. The chemical and physical properties of titanium metal will be briefly examined. Present and future applications for titanium will be discussed. Finally, the economics of titanium metal production also are analyzed as well as the advantages and disadvantages of various alternative extraction methods.

  6. ORAL HYGIENE OF PROSTHETIC DENTURE USER IN KODINGARENG ISLAND

    OpenAIRE

    NUR, NURUL KUSUMADEWI S.KG

    2008-01-01

    Objectives:to determine the level of oral hygiene for prosthetic denture user, especially for full-denture in Kodingareng Island. This researchincluded the distribution level of prosthetic denture user based on age and education.Methods: the method that used in this research is observational descriptive withcross sectional-studyas the research design. Variable result of the research determined in to 3, those are bad, middle, and good. Result:the highest percentage o...

  7. Design and Evaluation of a Prosthetic Knee Joint Using the Geared Five-Bar Mechanism.

    Science.gov (United States)

    Sun, Yuanxi; Ge, Wenjie; Zheng, Jia; Dong, Dianbiao

    2015-11-01

    This paper presents the mechanical design, dynamics analysis and ankle trajectory analysis of a prosthetic knee joint using the geared five-bar mechanism. Compared with traditional four-bar or six-bar mechanisms, the geared five-bar mechanism is better at performing diverse movements and is easy to control. This prosthetic knee joint with the geared five-bar mechanism is capable of fine-tuning its relative instantaneous center of rotation and ankle trajectory. The centrode of this prosthetic knee joint, which is mechanically optimized according to the centrode of human knee joint, is better in the bionic performance than that of a prosthetic knee joint using the four-bar mechanism. Additionally, the stability control of this prosthetic knee joint during the swing and stance phase is achieved by a motor. By adjusting the gear ratio of this prosthetic knee joint, the ankle trajectories of both unilateral and bilateral amputees show less deviations from expected than that of the four-bar knee joint.

  8. Reduced prosthetic stiffness lowers the metabolic cost of running for athletes with bilateral transtibial amputations.

    Science.gov (United States)

    Beck, Owen N; Taboga, Paolo; Grabowski, Alena M

    2017-04-01

    Inspired by the springlike action of biological legs, running-specific prostheses are designed to enable athletes with lower-limb amputations to run. However, manufacturer's recommendations for prosthetic stiffness and height may not optimize running performance. Therefore, we investigated the effects of using different prosthetic configurations on the metabolic cost and biomechanics of running. Five athletes with bilateral transtibial amputations each performed 15 trials on a force-measuring treadmill at 2.5 or 3.0 m/s. Athletes ran using each of 3 different prosthetic models (Freedom Innovations Catapult FX6, Össur Flex-Run, and Ottobock 1E90 Sprinter) with 5 combinations of stiffness categories (manufacturer's recommended and ± 1) and heights (International Paralympic Committee's maximum competition height and ± 2 cm) while we measured metabolic rates and ground reaction forces. Overall, prosthetic stiffness [fixed effect (β) = 0.036; P = 0.008] but not height ( P ≥ 0.089) affected the net metabolic cost of transport; less stiff prostheses reduced metabolic cost. While controlling for prosthetic stiffness (in kilonewtons per meter), using the Flex-Run (β = -0.139; P = 0.044) and 1E90 Sprinter prostheses (β = -0.176; P = 0.009) reduced net metabolic costs by 4.3-4.9% compared with using the Catapult prostheses. The metabolic cost of running improved when athletes used prosthetic configurations that decreased peak horizontal braking ground reaction forces (β = 2.786; P = 0.001), stride frequencies (β = 0.911; P < 0.001), and leg stiffness values (β = 0.053; P = 0.009). Remarkably, athletes did not maintain overall leg stiffness across prosthetic stiffness conditions. Rather, the in-series prosthetic stiffness governed overall leg stiffness. The metabolic cost of running in athletes with bilateral transtibial amputations is influenced by prosthetic model and stiffness but not height. NEW & NOTEWORTHY We measured the

  9. Titanium disilicide formation by sputtering of titanium on heated silicon substrate

    Science.gov (United States)

    Tanielian, M.; Blackstone, S.

    1984-09-01

    We have sputter deposited titanium on bare silicon substrates at elevated temperatures. We find that at a substrate temperature of about 515 °C titanium silicide is formed due to the reaction of the titanium with the Si. The resistivity of the silicide is about 15 μΩ cm and it is not etchable in a selective titanium etch. This process can have applications in low-temperature, metal-oxide-semiconductor self-aligned silicide formation for very large scale integrated

  10. Clinical Effectiveness of Using Aesthetic Fixed Prosthetic Appliances with Combined Occlusal Surface

    OpenAIRE

    Andrii Biben; Zinovii Ozhohan

    2017-01-01

    The objective of the research was to evaluate the clinical effectiveness of using aesthetic fixed prosthetic appliances with combined occlusal surface. Materials and methods. The study included 30 patients who were divided into 2 groups: Group I included 20 patients with combined occlusal surface of the crowns; Group II included 22 patients with ceramic occlusal surface of the crowns. The patients were observed 3, 6 and 12 months after prosthetic repair. Results. 6 months after prosthet...

  11. Clinical Presentation, Risk Factors, and Outcomes of Hematogenous Prosthetic Joint Infection in Patients with Staphylococcus aureus Bacteremia.

    Science.gov (United States)

    Tande, Aaron J; Palraj, Bharath Raj; Osmon, Douglas R; Berbari, Elie F; Baddour, Larry M; Lohse, Christine M; Steckelberg, James M; Wilson, Walter R; Sohail, M Rizwan

    2016-02-01

    Staphylococcus aureus bacteremia is a life-threatening condition that may lead to metastatic infection, including prosthetic joint infection. To assess clinical factors associated with hematogenous prosthetic joint infection, we retrospectively reviewed all patients with a joint arthroplasty in place at the time of a first episode of S. aureus bacteremia over a 5-year period at our institution. Patients with postsurgical prosthetic joint infection without hematogenous prosthetic joint infection were excluded. There were 85 patients (143 arthroplasties) with either no prosthetic joint infection (n = 50; 58.8%) or hematogenous prosthetic joint infection in at least one arthroplasty (n = 35; 41.2%). The odds of hematogenous prosthetic joint infection was significantly increased among patients with community-acquired S. aureus bacteremia (odds ratio [OR] 18.07; 95% confidence interval [CI] 2.64-infinity; P = .001), as compared with nosocomial S. aureus bacteremia, in which there were no patients with hematogenous prosthetic joint infection. After adjusting for S. aureus bacteremia classification, the presence of ≥3 joint arthroplasties in place was associated with a nearly ninefold increased odds of hematogenous prosthetic joint infection as compared with those with 1-2 joint arthroplasties in place (OR 8.55; 95% CI 1.44-95.71; P = .012). All but one joint with prosthetic joint infection demonstrated at least one clinical feature suggestive of infection. There were 4 additional S. aureus prosthetic joint infections diagnosed during a median of 3.4 years of follow-up post hospitalization for S. aureus bacteremia. Prosthetic joint infection is frequent in patients with existing arthroplasties and concomitant S. aureus bacteremia, particularly with community-acquired S. aureus bacteremia and multiple prostheses. In contrast, occult S. aureus prosthetic joint infection without clinical features suggestive of prosthetic joint infection at the time of S. aureus bacteremia

  12. Clinical characteristics, microbiology, and outcomes of prosthetic joint infection in Taiwan.

    Science.gov (United States)

    Tsai, Jen-Chih; Sheng, Wang-Huei; Lo, Wan-Yu; Jiang, Ching-Chuan; Chang, Shan-Chwen

    2015-04-01

    Prosthetic joint infection (PJI) after total knee or hip replacement is a devastating complication associated with substantial morbidity and economic cost. The incidence of prosthetic joint infection is increasing as the use of mechanical joint replacement increases. The treatment approach to prosthetic joint infection is based on different clinical situations such as a patient's comorbidities, epidemic microbiology data, and surgical procedures. The aim of our study was to understand clinical characteristics of prosthetic joint infection, the microbiology of the prosthetic joint infection, and the outcomes of different treatment strategies during 2006-2011. We retrospectively collected cases of prosthetic joint infection in the National Taiwan University Hospital between January 1, 2006 and December 31, 2011. The patients' characteristics, microbiology, outcomes, and factors associated with treatment success were recorded. One hundred and forty-four patients were identified as having PJI. Of these, 92 patients were entered into per-protocol analysis. Staphylococcus aureus was the most common causative organism (29.9%), followed by coagulase-negative Staphylococci (16.7%), and Enterococci (9.7%). The overall treatment success rate was 50%. Patients who received a two-stage revision had a better outcome, compared to patients who underwent other types of surgeries (70% vs. 32.7%, respectively; p < 0.001). In multivariate analysis, the two-stage revision was significantly associated with treatment success (odds ratio = 3.923, 95% confidence interval = 1.53-10.04). Our study demonstrates that Staphylococcus aureus was the most common causative organisms in PJI. Performing two-stage revisions was significantly associated with a better outcome. Copyright © 2013. Published by Elsevier B.V.

  13. New developments in prosthetic arm systems

    Directory of Open Access Journals (Sweden)

    Vujaklija I

    2016-07-01

    Full Text Available Ivan Vujaklija,1 Dario Farina,1 Oskar C Aszmann2 1Institute of Neurorehabilitation Systems, Bernstein Focus Neurotechnology Göttingen, University Medical Center Göttingen, Georg-August University, Göttingen, Germany; 2Christian Doppler Laboratory for Restoration of Extremity Function, Division of Plastic and Reconstructive Surgery, Department of Surgery, Medical University of Vienna, Vienna, Austria Abstract: Absence of an upper limb leads to severe impairments in everyday life, which can further influence the social and mental state. For these reasons, early developments in cosmetic and body-driven prostheses date some centuries ago, and they have been evolving ever since. Following the end of the Second World War, rapid developments in technology resulted in powered myoelectric hand prosthetics. In the years to come, these devices were common on the market, though they still suffered high user abandonment rates. The reasons for rejection were trifold – insufficient functionality of the hardware, fragile design, and cumbersome control. In the last decade, both academia and industry have reached major improvements concerning technical features of upper limb prosthetics and methods for their interfacing and control. Advanced robotic hands are offered by several vendors and research groups, with a variety of active and passive wrist options that can be articulated across several degrees of freedom. Nowadays, elbow joint designs include active solutions with different weight and power options. Control features are getting progressively more sophisticated, offering options for multiple sensor integration and multi-joint articulation. Latest developments in socket designs are capable of facilitating implantable and multiple surface electromyography sensors in both traditional and osseointegration-based systems. Novel surgical techniques in combination with modern, sophisticated hardware are enabling restoration of dexterous upper limb

  14. A mechanism to compensate undesired stiffness in joints of prosthetic hands

    NARCIS (Netherlands)

    Smit, G.; Plettenbrug, D.H.; Van der Helm, F.C.T.

    2014-01-01

    Background: Cosmetic gloves that cover a prosthetic hand have a parasitic positive stiffness that counteracts the flexion of a finger joint. Objectives: Reducing the required input torque to move a finger of a prosthetic hand by compensating the parasitic stiffness of the cosmetic glove. Study

  15. Granulicatella adiacens prosthetic hip joint infection after dental treatment.

    Science.gov (United States)

    Aweid, Osama; Sundararajan, Sabapathy; Teferi, Abraham

    2016-06-01

    Granulicatella adiacens is a Gram-positive bacteria and a normal component of oral flora. It is also found in dental plaques, endodontic abscesses and can rarely cause more serious infections. We describe a prosthetic hip joint infection in an 81-year-old fit and healthy man due to Granulicatella adiacens who underwent a prolonged dental intervention two days earlier without antibiotic prophylaxis. The infection was successfully treated with surgical intervention and a combination of antibiotics. The patient eventually succumbed to severe community-acquired pneumonia two months later. Current guidelines recommend avoidance of antibiotic prophylaxis prior to dental treatment in patients who have no co-morbidities and no prior operation on the index prosthetic joint. This case report indicates that infections of prosthetic joints may be associated with dental procedures even in fit and healthy patients without the recognized risk factors.

  16. [Tuberculous prosthetic knee joint infection: a case report and literature review].

    Science.gov (United States)

    Lara-Oya, A; Liébana-Martos, M C; Rodríguez-Granger, J; Sampedro-Martínez, A; Aliaga-Martínez, L; Gutierrez-Fernández, J; Navarro-Marí, J M

    2016-08-01

    Prosthetic late infection occurs in the second month after surgery in the context of haematogenous spread from another source. Prosthetic mycobacterial infection is a rare complication whose clinical management is not standardized. Patient of 77 years with no personal history except for diabetes and a prosthetic replacement of right knee with osteoarthritis three years ago. Patient goes to hospital emergency box for 6 months pain in the right knee with mechanical inflammatory signs but no fever associated. After their return within 5 days and clinical worsening is reporting growth of Mycobacterium tuberculosis in knee aspirate and antitubercular treatment is established for 9 months. Nuclear magnetic resonance imaging studies also confirmed the diagnosis of tuberculosis spondylitis in the clinical context of the patients. After surgery, M. tuberculosis was again isolated from intraoperative samples and therefore the patient received another batch of treatment for 9 months. After a year of monitoring, the development was acceptable but few months later, the patient died for cardiovascular causes. In the literature review, 15 publications with a total of 17 clinical cases of prosthetic infection by M. tuberculosis were found from 1980 to 2014. Prosthetic tuberculous arthritis, although it is a rare presentation, it should be noted, especially in patients with predisposing conditions with a history of tuberculosis infection.

  17. Tissue expander-stimulated lengthening of arteries for the treatment of midaortic syndrome in children.

    Science.gov (United States)

    Kim, Heung Bae; Vakili, Khashayar; Ramos-Gonzalez, Gabriel J; Stein, Deborah R; Ferguson, Michael A; Porras, Diego; Lock, James E; Chaudry, Gulraiz; Alomari, Ahmad; Fishman, Steven J

    2018-01-17

    Midaortic syndrome (MAS) is a rare condition characterized by stenosis of the abdominal aorta. Patients with disease refractory to medical management will usually require either endovascular therapy or surgery with use of prosthetic graft material for bypass or patch angioplasty. We report our early experience with a novel approach using a tissue expander (TE) to lengthen the normal native arteries in children with MAS, allowing primary aortic repair without the need for prosthetic graft material. We conducted a retrospective review of patients with MAS undergoing the TE-stimulated lengthening of arteries (TESLA) procedure at our institution from 2010 to 2014. Data are presented as mean (range). Five patients aged 4.8 years (3-8 years) underwent the TESLA procedure. Stages of this procedure include the following: stage I, insertion of retroaortic TE; stage II, serial TE injections; and stage III, final repair with excision of aortic stenosis and primary end-to-end aortic anastomosis. Stage II was completed in 4 months (1-9 months) with 12 (7-20) TE injections. Goal lengthening was achieved in all patients. Stage III could not be completed in one patient because of extreme aortic inflammation, which precluded safe excision of the aortic stenosis and required use of a prosthetic bypass graft. The other four patients completed stage III with two (one to three) additional vessels also requiring reconstruction (renal or mesenteric arteries). At 3.2 years (1-6 years) of follow-up, all patients are doing well. The TESLA procedure allows surgical correction of MAS without the need for prosthetic grafts in young children who are still growing. Copyright © 2017 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  18. Leaching of Titanium and Silicon from Low-Grade Titanium Slag Using Hydrochloric Acid Leaching

    Science.gov (United States)

    Zhao, Longsheng; Wang, Lina; Qi, Tao; Chen, Desheng; Zhao, Hongxin; Liu, Yahui; Wang, Weijing

    2018-05-01

    Acid-leaching behaviors of the titanium slag obtained by selective reduction of vanadium-bearing titanomagnetite concentrates were investigated. It was found that the optimal leaching of titanium and silicon were 0.7% and 1.5%, respectively. The titanium and silicon in the titanium slag were firstly dissolved in the acidic solution to form TiO2+ and silica sol, and then rapidly reprecipitated, forming hydrochloric acid (HCl) leach residue. Most of the silicon presented in the HCl leach residue as floccules-like silica gel, while most of the titanium was distributed in the nano-sized rod-like clusters with crystallite refinement and intracrystalline defects, and, as such, 94.3% of the silicon was leached from the HCl leach residue by alkaline desilication, and 96.5% of the titanium in the titanium-rich material with some rutile structure was then digested by the concentrated sulfuric acid. This provides an alternative route for the comprehensive utilization of titanium and silicon in titanium slag.

  19. Effect of microstructure on the elasto-viscoplastic deformation of dual phase titanium structures

    Science.gov (United States)

    Ozturk, Tugce; Rollett, Anthony D.

    2018-02-01

    The present study is devoted to the creation of a process-structure-property database for dual phase titanium alloys, through a synthetic microstructure generation method and a mesh-free fast Fourier transform based micromechanical model that operates on a discretized image of the microstructure. A sensitivity analysis is performed as a precursor to determine the statistically representative volume element size for creating 3D synthetic microstructures based on additively manufactured Ti-6Al-4V characteristics, which are further modified to expand the database for features of interest, e.g., lath thickness. Sets of titanium hardening parameters are extracted from literature, and The relative effect of the chosen microstructural features is quantified through comparisons of average and local field distributions.

  20. Diamondlike carbon coating as a galvanic corrosion barrier between dental implant abutments and nickel-chromium superstructures.

    Science.gov (United States)

    Ozkomur, Ahmet; Erbil, Mehmet; Akova, Tolga

    2013-01-01

    The objectives of this study were to evaluate the galvanic corrosion behavior between titanium and nickel-chromium (Ni-Cr) alloy, to investigate the effect of diamondlike carbon (DLC) coating over titanium on galvanic corrosion behavior between titanium and Ni-Cr alloy, and to evaluate the effect of DLC coating over titanium abutments on the fit and integrity of prosthetic assemblies by scanning electron microcopy (SEM). Five Ni-Cr and 10 titanium disks with a diameter of 5 mm and thickness of 3 mm were prepared. DLC coating was applied to five titanium disks. Electrode samples were prepared, and open circuit potential measurements, galvanic current measurements over platinum electrodes, and potentiodynamic polarization tests were carried out. For the SEM evaluation, 20 Ni-Cr alloy and 10 gold alloy superstructures were cast and prepared over 30 abutments. DLC coating was applied to 10 of the abutments. Following the fixation of prosthetic assemblies, the samples were embedded in acrylic resin and cross sectioned longitudinally. Internal fit evaluations were carried out through examination of the SEM images. Titanium showed more noble and electrochemically stable properties than Ni-Cr alloy. DLC coating over the cathode electrode served as an insulating film layer over the surface and prevented galvanic coupling. Results of the SEM evaluations indicated that the DLC-coated and titanium abutments showed no statistically significant difference in fit. Hence, no adverse effects on the adaptation of prosthetic components were found with the application of DLC coating over abutment surfaces. DLC coating might serve as a galvanic corrosion barrier between titanium abutments and Ni-Cr superstructures.

  1. Control of a powered prosthetic device via a pinch gesture interface

    Science.gov (United States)

    Yetkin, Oguz; Wallace, Kristi; Sanford, Joseph D.; Popa, Dan O.

    2015-06-01

    A novel system is presented to control a powered prosthetic device using a gesture tracking system worn on a user's sound hand in order to detect different grasp patterns. Experiments are presented with two different gesture tracking systems: one comprised of Conductive Thimbles worn on each finger (Conductive Thimble system), and another comprised of a glove which leaves the fingers free (Conductive Glove system). Timing tests were performed on the selection and execution of two grasp patterns using the Conductive Thimble system and the iPhone app provided by the manufacturer. A modified Box and Blocks test was performed using Conductive Glove system and the iPhone app provided by Touch Bionics. The best prosthetic device performance is reported with the developed Conductive Glove system in this test. Results show that these low encumbrance gesture-based wearable systems for selecting grasp patterns may provide a viable alternative to EMG and other prosthetic control modalities, especially for new prosthetic users who are not trained in using EMG signals.

  2. Prosthetic valve endocarditis caused by Staphylococcus capitis: report of 4 cases

    Directory of Open Access Journals (Sweden)

    Wada Yuko

    2011-10-01

    Full Text Available Abstract Although Staphylococcus capitis is considered to be a rare causative organism for prosthetic valve endocarditis, we report 4 such cases that were encountered at our hospital over the past 2 years. Case 1 was a 79-year-old woman who underwent aortic valve replacement with a bioprosthetic valve and presented with fever 24 days later. Transesophageal echocardiography revealed an annular abscess in the aorto-mitral continuity and mild perivalvular regurgitation. We performed emergency surgery 5 days after the diagnosis of prosthetic valve endocarditis was made. Case 2 was a 79-year-old woman presenting with fever 40 days after aortic valve replacement with a bioprosthesis. Transesophageal echocardiography showed vegetation on the valve, and she underwent urgent surgery 2 days after prosthetic valve endocarditis was diagnosed. In case 3, a 76-year-old man presented with fever 53 days after aortic valve replacement with a bioprosthesis. Vegetation on the prosthetic leaflet could be seen by transesophageal echocardiography. He underwent emergency surgery 2 days after the diagnosis of prosthetic valve endocarditis was made. Case 4 was a 68-year-old woman who collapsed at her home 106 days after aortic and mitral valve replacement with bioprosthetic valves. Percutaneous cardiopulmonary support was started immediately after massive mitral regurgitation due to prosthetic valve detachment was revealed by transesophageal echocardiography. She was transferred to our hospital by helicopter and received surgery immediately on arrival. In all cases, we re-implanted another bioprosthesis after removal of the infected valve and annular debridement. All patients recovered without severe complications after 2 months of antibiotic treatment, and none experienced re-infection during 163 to 630 days of observation. Since the time interval between diagnosis of prosthetic valve endocarditis and valve re-replacement ranged from 0 to 5 days, early surgical removal

  3. LOW-MOLECULAR-WEIGHT HEPARIN TREATMENT FAILURE IN PREVENTION OF PROSTHETIC MITRAL VALVE THROMBOSIS

    OpenAIRE

    David Šuran; Vojko Kanič; Tatjana Golob Gulič; Husam Franjo Naji; Robert Lipovec

    2009-01-01

    Background Prosthetic heart valve thrombosis (PHVT) represents a dangerous postoperative complication following prosthetic heart valve replacement. Incidence varies according to different data from 0.5–4 % per year following mitral or aortic valve replacement in spite of adequate oral anticoagulation with coumarins. Case report We are presenting a case of prosthetic mitral valve thrombosis as a result of 6-month lowmolecular-weight heparin (LMWH) (nadroparine) treatment failure. Our pat...

  4. Obtention of a prosthetic group for labelling of radioiodinated proteins

    International Nuclear Information System (INIS)

    Santos, Josefina da S.; Colturato, Maria Tereza; Araujo, Elaine B. de

    2000-01-01

    Antibodies and peptides labeled with radionuclides has been extensively used in radioimmunotherapy and radioimmunodetection. The principal problem with the use of radioiodinated proteins is the in vivo dehalogenation. The use of prosthetic groups for indirect labeling of proteins with radioiodine has showed to be useful on labeling proteins with greater in vivo stability. A procedure is described for the preparation of an radioiodinated prosthetic group (N-succinimidyl 4-radioiodine-benzoate-SIB), using procedure described by Stocklin et al, with the iodination of p-bromo-benzoic acid and subsequent reaction with TSTU. Preliminary labeling results showed that the prosthetic group can be obtained in a good yield. The coupling of the SIB to the protein will be studied using human IgG as protein model. (author)

  5. Synthesis of Titanium Oxycarbide from Titanium Slag by Methane-Containing Gas

    Science.gov (United States)

    Dang, Jie; Fatollahi-Fard, Farzin; Pistorius, Petrus Christiaan; Chou, Kuo-Chih

    2018-02-01

    In this study, reaction steps of a process for synthesis of titanium oxycarbide from titanium slag were demonstrated. This process involves the reduction of titanium slag by a methane-hydrogen-argon mixture at 1473 K (1200 °C) and the leaching of the reduced products by hydrofluoric acid near room temperature to remove the main impurity (Fe3Si). Some iron was formed by disproportionation of the main M3O5 phase before gaseous reduction started. Upon reduction, more iron formed first, followed by reduction of titanium dioxide to suboxides and eventually oxycarbide.

  6. A qualitative study of the challenges of providing pre-prosthetic rehabilitation in rural South Africa.

    Science.gov (United States)

    Ennion, Liezel; Johannesson, Anton

    2018-04-01

    There is a known shortage of rehabilitation staff in rural settings and a sharp increase in the number of lower limb amputations being performed. A lack of adequate pre-prosthetic rehabilitation will result in worse physical and psychological outcomes for a person with a lower limb amputation, and they will not be eligible to be fitted with a prosthesis. To explore therapists' experiences with providing pre-prosthetic rehabilitation in a rural setting. A qualitative descriptive approach was used to collect and analyse data. Data were collected from 17 purposively sampled therapists in five district hospitals in a rural community in South Africa. Data were collected in two rounds of focus groups to explore the challenges of providing pre-prosthetic rehabilitation in rural South Africa. The main themes identified in the study were (1) a lack of government health system support, (2) poor socioeconomic circumstances of patients and (3) cultural factors that influence rehabilitation. These themes all negatively influence the therapists' ability to follow up patients for pre-prosthetic rehabilitation after discharge from hospital. A lack of adequate pre-prosthetic rehabilitation is a substantial barrier to prosthetic fitting in rural South Africa. Patients who do not receive pre-prosthetic rehabilitation have a poorly shaped residuum or other complications such as knee or hip joint contractures which disqualifies them from being referred to prosthetic services. Therapists involved in this study identified the most important barriers to patients having access to prosthetic services. Clinical relevance Pre-prosthetic rehabilitation provides care of the residuum; maintenance or improvement of physical strength, joint range of motion and referral to a prosthetist. By exploring the challenges known to exist in this service, we can identify potential ways to reduce these barriers and improve the lives of those who use it.

  7. Prosthetic design directives: Low-cost hands within reach.

    Science.gov (United States)

    Jones, G K; Rosendo, A; Stopforth, R

    2017-07-01

    Although three million people around the world suffer from the lack of one or both upper limbs 80% of this number is located within developing countries. While prosthetic prices soar with technology 3D printing and low cost electronics present a sensible solution for those that cannot afford expensive prosthetics. The electronic and control design of a low-cost prosthetic hand, the Touch Hand II, is discussed. This paper shows that sensorless techniques can be used to reduce design complexities, costs, and provide easier access to the electronics. A closing and opening finite state machine (COFSM) was developed to handle the actuated digit joint control state and a supervisory switching control scheme, used for speed and grip strength control. Three torque and speed settings were created to be preset for specific grasps. The hand was able to replicate ten frequently used grasps and grip some common objects. Future work is necessary to enable a user to control it with myoelectric signals (MESs) and to solve operational problems related to electromagnetic interference (EMI).

  8. Anaerobic prosthetic joint infection.

    Science.gov (United States)

    Shah, Neel B; Tande, Aaron J; Patel, Robin; Berbari, Elie F

    2015-12-01

    In an effort to improve mobility and alleviate pain from degenerative and connective tissue joint disease, an increasing number of individuals are undergoing prosthetic joint replacement in the United States. Joint replacement is a highly effective intervention, resulting in improved quality of life and increased independence [1]. By 2030, it is predicted that approximately 4 million total hip and knee arthroplasties will be performed yearly in the United States [2]. One of the major complications associated with this procedure is prosthetic joint infection (PJI), occurring at a rate of 1-2% [3-7]. In 2011, the Musculoskeletal Infectious Society created a unifying definition for prosthetic joint infection [8]. The following year, the Infectious Disease Society of America published practice guidelines that focused on the diagnosis and management of PJI. These guidelines focused on the management of commonly encountered organisms associated with PJI, including staphylococci, streptococci and select aerobic Gram-negative bacteria. However, with the exception of Propionibacterium acnes, management of other anaerobic organisms was not addressed in these guidelines [1]. Although making up approximately 3-6% of PJI [9,10], anaerobic microorganisms cause devastating complications, and similar to the more common organisms associated with PJI, these bacteria also result in significant morbidity, poor outcomes and increased health-care costs. Data on diagnosis and management of anaerobic PJI is mostly derived from case reports, along with a few cohort studies [3]. There is a paucity of published data outlining factors associated with risks, diagnosis and management of anaerobic PJI. We therefore reviewed available literature on anaerobic PJI by systematically searching the PubMed database, and collected data from secondary searches to determine information on pathogenesis, demographic data, clinical features, diagnosis and management. We focused our search on five commonly

  9. A clinical survey about commercial games in lower limb prosthetic rehabilitation.

    Science.gov (United States)

    Imam, Bita; Miller, William C; Finlayson, Heather C; Eng, Janice J; Jarus, Tal

    2018-06-01

    Despite the popularity of commercial games in lower limb prosthetic rehabilitation, data about their prevalence of use as well as therapists' perspectives about these games are still lacking. To learn about the prevalence of use of commercial games in lower limb prosthetic rehabilitation and therapists' perspectives about these games. Cross-sectional. An online survey was sent to physical and occupational therapists across prosthetic rehabilitation facilities in Canada. The survey had questions about the use of commercial games and therapists' perspectives. Data were collected from 82 therapists. Overall, 46.3% (38/82) reported that they use commercial games; of those, 94.7% (36/38) used the Nintendo Wii Fit. The most reported perceived benefits were the Wii Fit helping to improve weight shifting ( n = 76/82, 92.7%) and balance ( n = 75/82, 91.5%), and being motivating and complementing traditional therapy ( n = 75/82, 91.5%). The most reported perceived barriers/challenges were lack of time and familiarity with the games ( n = 58/82, 70.7%). Commercial games, particularly the Wii Fit, are commonly used in lower prosthetic rehabilitation in Canada. Most of the queried therapists view the Wii Fit positively. Knowledge translation activities and developing standard treatment protocols would be helpful in minimizing the barriers identified in this study. Clinical relevance The Wii Fit is prevalent in lower limb prosthetic rehabilitation in Canada and it is viewed positively by therapists as having the potential to improve balance and weight bearing, making rehabilitation more motivating, and complementing traditional therapy. Future studies should investigate the efficacy of the Wii Fit in prosthetic rehabilitation.

  10. Quality Assessment of Prosthetic Rehabilitation Using Aesthetic Fixed Restorations

    Directory of Open Access Journals (Sweden)

    Zinovii Ozhohan

    2018-04-01

    Full Text Available The objective of the research was to study and assess the quality of prosthetic treatment using aesthetic fixed restorations. Materials and methods. The study included 79 patients without a comorbidity who underwent prosthetic rehabilitation. All the patients were divided into 3 groups: Group I included 25 patients with metal-plastic restorations; Group II comprised 34 patients with porcelain-fused-to-metal restorations; Group III consisted of 20 patients with a combined occlusal surface of prosthetic restorations. The patients were observed 6 months after prosthetic repair. Only patients with single molar and premolar crowns were examined. Bridge prostheses were not taken into account in order to eliminate the effect of masticatory force redistribution on the abutment crowns. Results. In Group I, 11 (44% patients were satisfied with the results of prosthetic treatment. In Group II, 25 (78.12% patients reported that they were satisfied with their treatment. In Group III, there were 17 (85% patients satisfied with their outcome. However, the patients’ complaints are often subjective and do not fully reflect the objective state of the dentoalveolar system. An objective examination revealed that in indirect restorations, marginal periodontium pathology is typical. Conclusions. Aesthetic fixed restorations with a combined occlusal surface have demonstrated good clinical results, even at long-term follow-up. Combining positive properties of two different construction materials, namely zirconium dioxide and ceramics, they reduce the risk of complications such as marginal periodontium pathology and chipping along the occlusal surface as well as contribute to minimal abrasion of the occlusal surfaces of the antagonistic teeth. We cannot recommend metal-plastic restorations due to their low clinical effectiveness, poor aesthetic qualities as well as a high level of marginal periodontium pathology.

  11. Effect of Modifying Prosthetic Socket Base Materials by Adding Nanodiamonds

    Directory of Open Access Journals (Sweden)

    Lifang Ma

    2015-01-01

    Full Text Available The curing process of prosthetic socket base materials requires attention owing to a series of associated problems that are yet to be addressed and solved. However, to date, few relevant studies have been reported. In this paper, nanodiamonds modified with a silane coupling agent were dispersed into a prosthetic socket base material, and the performance of the modified base materials was investigated. Adding a predetermined amount of nanodiamonds to the prosthetic socket base material increased the glass transition temperature, improved the mechanical properties of the cured base material, and reduced the influence of the volatile gas formed during the curing process on the environment. With increasing nanodiamond contents, the glass transition temperature increased and the mechanical properties improved slightly. Owing to the high thermal conductivity of the nanodiamonds, the localized heat, as a result of the curing process, could be dissipated and released. Thus, adding nanodiamonds led to a more uniform temperature field forming in the curing system. This improved the curing process and reduced the formation of volatile monomers, thereby decreasing the adverse impact of the generated volatile gases on the environment. All of these provide a potential strategy for modifying prosthetic socket base materials.

  12. Titanium by design: TRIP titanium alloy

    Science.gov (United States)

    Tran, Jamie

    Motivated by the prospect of lower cost Ti production processes, new directions in Ti alloy design were explored for naval and automotive applications. Building on the experience of the Steel Research Group at Northwestern University, an analogous design process was taken with titanium. As a new project, essential kinetic databases and models were developed for the design process and used to create a prototype design. Diffusion kinetic models were developed to predict the change in phase compositions and microstructure during heat treatment. Combining a mobility database created in this research with a licensed thermodynamic database, ThermoCalc and DICTRA software was used to model kinetic compositional changes in titanium alloys. Experimental diffusion couples were created and compared to DICTRA simulations to refine mobility parameters in the titanium mobility database. The software and database were able to predict homogenization times and the beta→alpha plate thickening kinetics during cooling in the near-alpha Ti5111 alloy. The results of these models were compared to LEAP microanalysis and found to be in reasonable agreement. Powder metallurgy was explored using SPS at GM R&D to reduce the cost of titanium alloys. Fully dense Ti5111 alloys were produced and achieved similar microstructures to wrought Ti5111. High levels of oxygen in these alloys increased the strength while reducing the ductility. Preliminary Ti5111+Y alloys were created, where yttrium additions successfully gettered excess oxygen to create oxides. However, undesirable large oxides formed, indicating more research is needed into the homogeneous distribution of the yttrium powder to create finer oxides. Principles established in steels were used to optimize the beta phase transformation stability for martensite transformation toughening in titanium alloys. The Olson-Cohen kinetic model is calibrated to shear strains in titanium. A frictional work database is established for common alloying

  13. Strength evaluation of prosthetic check sockets, copolymer sockets, and definitive laminated sockets.

    Science.gov (United States)

    Gerschutz, Maria J; Haynes, Michael L; Nixon, Derek; Colvin, James M

    2012-01-01

    A prosthesis encounters loading through forces and torques exerted by the person with amputation. International Organization for Standardization (ISO) standard 10328 was designed to test most lower-limb prosthetic components. However, this standard does not include prosthetic sockets. We measured static failure loads of prosthetic sockets using a modified ISO 10328 and then compared them with the criteria set by this standard for other components. Check socket (CS) strengths were influenced by thickness, material choice, and fabrication method. Copolymer socket (CP) strengths depended on thickness and fabrication methods. A majority of the CSs and all of the CPs failed to pass the ISO 10328 ductile loading criterion. In contrast, the strengths of definitive laminated sockets (DLs) were influenced more by construction material and technique. A majority of the DLs failed to pass the ISO 10328 brittle loading criterion. Analyzing prosthetic sockets from a variety of facilities demonstrated that socket performance varies considerably between and within facilities. The results from this article provide a foundation for understanding the quality of prosthetic sockets, some insight into possible routes for improving the current care delivered to patients, and a comparative basis for future technology.

  14. Computed Tomography of Prosthetic Heart Valves

    NARCIS (Netherlands)

    Habets, J.

    2012-01-01

    Prosthetic heart valve (PHV) dysfunction is an infrequent but potentially life-threatening disease with a heterogeneous clinical presentation. Patients with PHV dysfunction clinically can present with symptoms of congestive heart failure (dyspnea, fatigue, edema), fever, angina pectoris, dizziness

  15. Evaluation of 3D printed anatomically scalable transfemoral prosthetic knee.

    Science.gov (United States)

    Ramakrishnan, Tyagi; Schlafly, Millicent; Reed, Kyle B

    2017-07-01

    This case study compares a transfemoral amputee's gait while using the existing Ossur Total Knee 2000 and our novel 3D printed anatomically scalable transfemoral prosthetic knee. The anatomically scalable transfemoral prosthetic knee is 3D printed out of a carbon-fiber and nylon composite that has a gear-mesh coupling with a hard-stop weight-actuated locking mechanism aided by a cross-linked four-bar spring mechanism. This design can be scaled using anatomical dimensions of a human femur and tibia to have a unique fit for each user. The transfemoral amputee who was tested is high functioning and walked on the Computer Assisted Rehabilitation Environment (CAREN) at a self-selected pace. The motion capture and force data that was collected showed that there were distinct differences in the gait dynamics. The data was used to perform the Combined Gait Asymmetry Metric (CGAM), where the scores revealed that the overall asymmetry of the gait on the Ossur Total Knee was more asymmetric than the anatomically scalable transfemoral prosthetic knee. The anatomically scalable transfemoral prosthetic knee had higher peak knee flexion that caused a large step time asymmetry. This made walking on the anatomically scalable transfemoral prosthetic knee more strenuous due to the compensatory movements in adapting to the different dynamics. This can be overcome by tuning the cross-linked spring mechanism to emulate the dynamics of the subject better. The subject stated that the knee would be good for daily use and has the potential to be adapted as a running knee.

  16. The radiology of prosthetic heart valves

    International Nuclear Information System (INIS)

    Steiner, R.M.; Flicker, S.

    1985-01-01

    The development of prosthetic heart valves in the late 1950s ushered in a new era in the treatment of heart disease. The radiologist has an important role to play preoperatively in the diagnosis of valvular heart disease. Radiology is valuable in identification of the implanted prosthetic valve and recognition of complications associated with valve implantation. Radiologists must be familiar with the imaging techniques best suited to evaluate the function of the valve prosthesis in question. In this chapter the authors discuss the radiographic approach to the evaluation of the status of patients for valve replacement and the imaging problems peculiar to the types of valves in current use. The relative value of plain-film radiography, fluoroscopy, videorecording and cinerecording, and aortography is addressed, as well as the potential value of magnetic resonance imaging and subsecond dynamic computed tomography

  17. Re-operation for aortic and mitral prosthetic dysfunctions.

    Science.gov (United States)

    Kaul, T K; Sastry, M R; Mercer, J L; Meade, J B

    1985-01-01

    The overall incidence of re-operation and prosthetic valve endocarditis was low in the present series as mechanical prostheses were used predominantly. The prosthetic dysfunctions were less frequent following the primary implantation with Bjork Shiley prostheses, but high operative risk was associated with the clotted Bjork Shiley prostheses. We also had unusual experience of strut fracture and sticking of Bjork Shiley discs in the closed position in both aortic and mitral positions. The early deaths were nil since the use of cardioplegic protection. Intra-operative bleeding due to adhesions can be minimised by using synthetic or heterologous pericardium during the primary operation.

  18. Corrosion of titanium and titanium alloys in spent fuel repository conditions - literature review

    International Nuclear Information System (INIS)

    Aho-Mantila, I.; Haenninen, H.; Aaltonen, P.; Taehtinen, S.

    1985-03-01

    The spent nuclear fuel is planned to be disposed in Finnish bedrock. The canister of spent fuel in waste repository is one barrier to the release of radionuclides. It is possible to choose a canister material with a known, measurable corrosion rate and to make it with thickness allowing corrosion to occur. The other possibility is to use a material which is nearly immune to general corrosion. In this second category there are titanium and titanium alloys which exhibit a very high degree of resistance to general corrosion. In this literature study the corrosion properties of unalloyed titanium, titanium alloyed with palladium and titanium alloyed with molybdenum and nickel are reviewed. The two titanium alloys own in addition to the excellent general corrosion properties outstanding properties against localized corrosion like pitting or crevice corrosion. Stress corrosion cracking and corrosion fatique of titanium seem not to be a problem in the repository conditions, but the possibilities of delayed cracking caused by hydrogen should be carefully appreciated. (author)

  19. Future Research Opportunities in Peri-Prosthetic Joint Infection Prevention.

    Science.gov (United States)

    Berbari, Elie; Segreti, John; Parvizi, Javad; Berríos-Torres, Sandra I

    Peri-prosthetic joint infection (PJI) is a serious complication of prosthetic joint arthroplasty. A better understanding and reversal of modifiable risk factors may lead to a reduction in the incidence of incisional (superficial and deep) and organ/space (e.g., PJI) surgical site infections (SSI). Recently, the Centers for Disease Control and Prevention (CDC) and the Healthcare Infection Control Practices Advisory Committee (HICPAC) published the Guideline for Prevention of Surgical Site Infection. This targeted update applies evidence-based methodology in drafting recommendations for potential strategies to reduce the risk of SSI both across surgical procedures and specifically in prosthetic joint arthroplasty. A panel of PJI content experts identified nine PJI prevention research opportunities based on both evidence gaps identified through the guideline development process (transfusion, immunosuppressive therapy, anticoagulation, orthopedic space suit, and biofilm) and expert opinion (anesthesia, operative room environment, glycemic control, and Staphylococcus aureus nasal screening and decolonization. This article offers a road map for PJI prevention research.

  20. Experiences of providing prosthetic and orthotic services in Sierra Leone--the local staff's perspective.

    Science.gov (United States)

    Magnusson, Lina; Ahlström, Gerd

    2012-01-01

    In Sierra Leone, West Africa, there are many people with disabilities in need of rehabilitation services after a long civil war. The aim of this qualitative study was to explore the experiences of prosthetic and orthotic service delivery in Sierra Leone from the local staff's perspective. Fifteen prosthetic and orthotic technicians working at all the rehabilitation centres providing prosthetic and orthotic services in Sierra Leone were interviewed. The interviews were transcribed and subjected to latent content analysis. One main theme emerged: sense of inability to deliver high-quality prosthetic and orthotic services. This main theme was generated from eight sub-themes: Desire for professional development; appraisals of work satisfaction and norms; patients neglected by family; limited access to the prosthetic and orthotic services available; problems with materials and machines; low public awareness concerning disabilities; marginalisation in society and low priority on the part of government. The findings illustrated traditional beliefs about the causes of disability and that the public's attitude needs to change to include and value people with disabilities. Support from international organisations was considered necessary as well as educating more prosthetic and orthotic staff to a higher level.

  1. Complete oral rehabilitation of a deep bite patient with Ewing’s sarcoma; surgical and prosthetic phases: A clinical report

    Directory of Open Access Journals (Sweden)

    Mehran Bahrami

    2017-01-01

    Full Text Available Introduction: Ewings sarcoma (ES is an unusual, aggressive malignant neoplasm occurring primarily in the long bones of the lower and upper extremities followed by pelvis, ribs, vertebrae, skull, and jaws-bones. Patients with ES tumor need long-term complete oral reconstruction. The location of the primary tumor in the face is predominantly in the mandible, and usually in the posterior mandible. Case Report: Here, both surgical procedures and prosthetic reconstruction in three stages of a 10-year-old childs life presented. Definitive prosthetic reconstruction is extremely challenging in such patients after previous excessive surgical resection, especially when the patient has complex dental abnormality. Fixed dental prostheses and implant-supported fixed restorations have been selected as the preferred treatment option in this case after increasing occlusal vertical dimension (OVD to create sufficient interocclusal space (IOS. Discussion: In this case, ES patient treated in three phases. In the first-stage, only surgical resection of tumor and bone graft reconstruction with titanium plate fixation was performed. In the second-stage, Lefort I surgery for maxilla with dental implants insertion in mandible was done simultaneously. For definitive restorations fabrication, it was mandatory to increase occlusal vertical dimension (OVD to create sufficient inter-occlusal space (IOS for the restorations. OVD has been altered to achieve more stable relationship of mandibular teeth with maxillary teeth, and to obtain an optimum esthetic and functional result. Several factors should be considered as determinants for increasing the OVD such as remaining tooth structure, the space available for the restorations such as the current situation, occlusal variables, and esthetics.

  2. Capnocytophaga canimorsus: a rare case of conservatively treated prosthetic valve endocarditis.

    Science.gov (United States)

    Jalava-Karvinen, Päivi; Grönroos, Juha O; Tuunanen, Helena; Kemppainen, Jukka; Oksi, Jarmo; Hohenthal, Ulla

    2018-05-01

    We describe a rare case of prosthetic valve endocarditis caused by the canine bacterium Capnocytophaga canimorsus in a male aged 73 years. The diagnosis of infective endocarditis was unequivocal, as it blood cultures were positive for C. canimorsus and vegetations were detected on transesophageal echocardiography; the modified Duke criteria were fulfilled. PET-CT showed intense 18 F-FDG uptake of the prosthetic valve area. The patient was treated with antibiotics alone (no surgery), and is now on life-long suppressive antibiotic therapy. To our knowledge, this is the third reported case of prosthetic valve endocarditis caused by C. canimorsus and the first one to have been treated conservatively. © 2018 APMIS. Published by John Wiley & Sons Ltd.

  3. In vitro comparison between α-tocopheryl acetate and α-tocopheryl phosphate against bacteria responsible of prosthetic and joint infections.

    Directory of Open Access Journals (Sweden)

    Alessandro Bidossi

    Full Text Available Biofilm-related infections represent a recurrent problem in the orthopaedic setting. In recent years, great interest was directed towards the identification of novel molecules capable to interfere with pathogens adhesion and biofilm formation on implant surfaces. In this study, two stable forms of α-tocopherol, the hydrophobic acetate ester and the water-soluble phosphate ester, were tested in vitro as coating for titanium prosthesis. Antimicrobial activity against microorganisms responsible of prosthetic and joints infections was assessed by broth microdilution method. In addition, α-tocopherol esters were evaluated for both their ability to hamper bacterial adhesion to and biofilm formation on sandblasted titanium surfaces. Results showed that only α-tocopheryl phosphate displayed antimicrobial activity against the tested strains. Both esters were able to significantly interfere with bacterial adhesion and to prevent biofilm formation, especially by Staphylococcus aureus and Staphylococcus epidermidis. The activity of α-tocopheryl phosphate was greater than that of α-tocopheryl acetate. Alterations at membrane levels have been reported in literature and may be likely responsible for the interference on bacterial adhesion and biofilm formation shown by α-tocopherol esters. Although further studies are needed to better investigate the mechanisms of action and the spectrum of activity of α-tocopherol esters, these characteristics together with the positive effect on wound healing and immune response, make these molecules promising candidate for coating in order to prevent implant-associated infections.

  4. Mitral Prosthetic Valve Obstruction and Its Complications

    Directory of Open Access Journals (Sweden)

    Rajesh Rajan

    2015-12-01

    Full Text Available Prosthetic Valve Obstruction (PVO is a serious complication which is associated with increased morbidity and mortality. This could result from thrombus formation, development of pannus, or a combination of both. Patients with this complication often present with symptoms and signs of heart failure, systemic embolism, acute cardiovascular collapse, and sudden death. Transesophageal echocardiography and cine fluoroscopy play a vital role in diagnosis of this potentially lethal condition. Herein, we reported a 56-year-old male patient who presented with severe heart failure and was found to have obstructed ATS27 bileaflet mitral prosthetic valve. Thrombolysis and redo surgery are two important options for treating this condition although guidelines for choosing between the two are not very definite.

  5. Chitosan patterning on titanium alloys

    OpenAIRE

    Gilabert Chirivella, Eduardo; Pérez Feito, Ricardo; Ribeiro, Clarisse; Ribeiro, Sylvie; Correia, Daniela; González Martin, María Luisa; Manero Planella, José María; Lanceros Méndez, Senentxu; Gallego Ferrer, Gloria; Gómez Ribelles, José Luis

    2017-01-01

    Titanium and its alloys are widely used in medical implants because of their excellent properties. However, bacterial infection is a frequent cause of titanium-based implant failure and also compromises its osseointegration. In this study, we report a new simple method of providing titanium surfaces with antibacterial properties by alternating antibacterial chitosan domains with titanium domains in the micrometric scale. Surface microgrooves were etched on pure titanium disks at i...

  6. Effect of metal selection and porcelain firing on the marginal accuracy of titanium-based metal ceramic restorations.

    Science.gov (United States)

    Shokry, Tamer E; Attia, Mazen; Mosleh, Ihab; Elhosary, Mohamed; Hamza, Tamer; Shen, Chiayi

    2010-01-01

    Titanium is the most biocompatible metal used for dental casting; however, there is concern about its marginal accuracy after porcelain application since this aspect has direct influence on marginal fit. The purpose of this study was to determine the effect that metal selection and the porcelain firing procedure have on the marginal accuracy of metal ceramic prostheses. Cast CP Ti, milled CP Ti, cast Ti-6Al-7Nb, and cast Ni-Cr copings (n=5) were fired with compatible porcelains (Triceram for titanium-based metals and VITA VMK 95 for Ni-Cr alloy). The Ni-Cr alloy fired with its porcelain served as the control. Photographs of metal copings placed on a master die were made. Marginal discrepancy was determined on the photographs using an image processing program at 8 predetermined locations before airborne-particle abrasion for porcelain application, after firing of the opaque layer, and after firing of the dentin layer. Repeated-measures 2-way ANOVA was used to investigate the effect of metal selection and firing stage, and paired t tests were used to determine the effect of each firing stage within each material group (alpha=.05). ANOVA showed that both metal selection and firing stage significantly influenced the measured marginal discrepancy (Pcast Ti-6Al-7Nb alloy (P=.003). Titanium copings fabricated by CAD/CAM demonstrated the least marginal discrepancy among all groups, while the base metal (Ni-Cr) groups exhibited the most discrepancy of all groups tested. Copyright 2010 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  7. Utilization of penile prosthesis and male incontinence prosthetics in Saudi Arabia

    Directory of Open Access Journals (Sweden)

    Amjad Alwaal

    2017-01-01

    Conclusions: There is an increased utilization of penile prosthetics in Saudi Arabia. The private sector performs the majority of penile prosthesis procedures, and most of them are of the semirigid type. The governmental sector is more likely to perform inflatable penile prosthesis and male incontinence device procedures. Male incontinence prosthetics' use is very limited in Saudi Arabia.

  8. Remote transient Lactobacillus animalis bacteremia causing prosthetic hip joint infection: a case report.

    Science.gov (United States)

    Somayaji, R; Lynch, T; Powell, J N; Gregson, D

    2016-11-04

    Lactobacillus spp. are uncommon pathogens in immunocompetent hosts, and even rarer causes of prosthetic device infections. A case of chronic hip prosthetic joint infection (PJI) caused by L. animalis is described. This occurred 5 years after a transient bacteremia with the same organism. Whole genome sequencing of both isolates proved this PJI infection resulted from this remote bacteremia. We document that prosthetic joint infections may be a consequence of bacteremia as much as 3 years before the onset of symptoms.

  9. Aspects of the practical application of titanium alloys after low temperature nitriding glow discharge in hydrogen- free -gas media

    International Nuclear Information System (INIS)

    Mashovets, N.S.; Pastukh, I.M.; Voloshko, S.M.

    2017-01-01

    Highlights: • Surface modification of titanium alloys were carried out by low-temperature nitriding in a glow discharge in hydrogen-free environment. • Research into the phase composition was performed by X-ray diffraction, X-ray photoelectron spectroscopy (XPS) and Auger electron spectroscopy (AES). • The above material shows the promise of the technology of low-temperature hydrogen-nitriding by glow discharge. This greatly expands the range of practical applications of titanium alloys. - Abstract: X-ray diffraction analysis, X-ray photoelectron spectroscopy, and Electron Auger-spectroscopy investigation of phase transformation on the surface of the VT8 titanium alloy after a low temperature hydrogen-free nitriding in a glow discharge. Operational characteristics of titanium alloys defined physical-mechanical characteristics of the surface and their phase composition, which depend on the process parameters of nitriding. Surface modification of titanium alloys were carried out by low-temperature nitriding in a glow discharge in hydrogen-free environment. The main advantage of this method lies in the absence of hydrogen embrittlement and complete environmental safety process. Application of the glow discharge can not only speed up the process by the order of the diffusion surface saturation with nitrogen, but also significantly alters the kinetics of the process and quality of the nitrided layer, in particular its physio-mechanical properties and phase composition. For research purposes, the standards from an α + β alloy Ti-Al6-Cr2-Mo2,5 (VT8) were used. Research into the phase composition was performed by X-ray diffraction, X-ray photoelectron spectroscopy (XPS) and Auger electron spectroscopy (AES). Stratified analysis by AES was conducted by etching the surface of the samples’ argon ion beam with diameters of 1.5 mm with an energy of 3000 eV and a current density of 400 mA/cm 2 . The above material shows the promise of the technology of low

  10. Aspects of the practical application of titanium alloys after low temperature nitriding glow discharge in hydrogen- free -gas media

    Energy Technology Data Exchange (ETDEWEB)

    Mashovets, N.S., E-mail: mashovets@rambler.ru [Khmelnickiy National University (Ukraine); Pastukh, I.M., E-mail: pastim@mail.ru [Khmelnickiy National University (Ukraine); Voloshko, S.M. [Khmelnickiy National University (Ukraine); National Technical University of Ukraine “Kyiv Polytechnic Institute” (Ukraine)

    2017-01-15

    Highlights: • Surface modification of titanium alloys were carried out by low-temperature nitriding in a glow discharge in hydrogen-free environment. • Research into the phase composition was performed by X-ray diffraction, X-ray photoelectron spectroscopy (XPS) and Auger electron spectroscopy (AES). • The above material shows the promise of the technology of low-temperature hydrogen-nitriding by glow discharge. This greatly expands the range of practical applications of titanium alloys. - Abstract: X-ray diffraction analysis, X-ray photoelectron spectroscopy, and Electron Auger-spectroscopy investigation of phase transformation on the surface of the VT8 titanium alloy after a low temperature hydrogen-free nitriding in a glow discharge. Operational characteristics of titanium alloys defined physical-mechanical characteristics of the surface and their phase composition, which depend on the process parameters of nitriding. Surface modification of titanium alloys were carried out by low-temperature nitriding in a glow discharge in hydrogen-free environment. The main advantage of this method lies in the absence of hydrogen embrittlement and complete environmental safety process. Application of the glow discharge can not only speed up the process by the order of the diffusion surface saturation with nitrogen, but also significantly alters the kinetics of the process and quality of the nitrided layer, in particular its physio-mechanical properties and phase composition. For research purposes, the standards from an α + β alloy Ti-Al6-Cr2-Mo2,5 (VT8) were used. Research into the phase composition was performed by X-ray diffraction, X-ray photoelectron spectroscopy (XPS) and Auger electron spectroscopy (AES). Stratified analysis by AES was conducted by etching the surface of the samples’ argon ion beam with diameters of 1.5 mm with an energy of 3000 eV and a current density of 400 mA/cm{sup 2}. The above material shows the promise of the technology of low

  11. On the use of titanium hydride for powder injection moulding of titanium-based alloys

    International Nuclear Information System (INIS)

    Carrenoo-Morelli, E.; Bidaux, J.-E.

    2009-01-01

    Full text: Titanium and titanium-based alloys are excellent materials for a number of engineering applications because of their high strength, lightweight, good corrosion resistance, non magnetic characteristic and biocompatibility. The current processing steps are usually costly, and there is a growing demand for net-shape solutions for manufacturing parts of increasing complexity. Powder injection moulding is becoming a competitive alternative, thanks to the advances in production of good quality base-powders, binders and sintering facilities. Titanium hydride powders, have the attractiveness of being less reactive than fine titanium powders, easier to handle, and cheaper. This paper summarizes recent advances on PIM of titanium and titanium alloys from TiH2 powders, including shape-memory NiTi alloys. (author)

  12. DME Prosthetics Orthotics, and Supplies Fee Schedule

    Data.gov (United States)

    U.S. Department of Health & Human Services — Durable Medical Equipment, Prosthetics-Orthotics, and Supplies Fee Schedule. The list contains the fee schedule amounts, floors, and ceilings for all procedure codes...

  13. Occlusion properties of prosthetic contact lenses for the treatment of amblyopia.

    Science.gov (United States)

    Collins, Randall S; McChesney, Megan E; McCluer, Craig A; Schatz, Martha P

    2008-12-01

    The efficacy of opaque contact lenses as occlusion therapy for amblyopia has been established in the literature. Prosthetic contact lenses use similar tints to improve cosmesis in scarred or deformed eyes and may be an alternative in occlusion therapy. To test this idea, we determined the degree of vision penalization elicited by prosthetic contact lenses and their effect on peripheral fusion. We tested 19 CIBA Vision DuraSoft 3 Prosthetic soft contact lenses with varying iris prints, underprints, and opaque pupil sizes in 10 volunteers with best-corrected Snellen distance visual acuity of 20/20 or better in each eye. Snellen visual acuity and peripheral fusion using the Worth 4-Dot test at near were measured on each subject wearing each of the 19 lenses. Results were analyzed with 3-factor analysis of variance. Mean visual acuity through the various lenses ranged from 20/79 to 20/620. Eight lenses allowed preservation of peripheral fusion in 50% or more of the subjects tested. Iris print pattern and opaque pupil size were significant factors in determining visual acuity (p occlusion with prosthetic contact lenses a viable therapy for amblyopia. The degree of penalization can be varied and different iris print patterns and pupil sizes, using peripheral fusion, can be preserved with some lenses. Prosthetic contact lenses can be more cosmetically appealing and more tolerable than other amblyopia treatment modalities. These factors may improve compliance in occlusion therapy.

  14. [Virtual Planning of Prosthetic Treatment of the Orbit].

    Science.gov (United States)

    Veit, Johannes A; Thierauf, Julia; Egner, Kornelius; Wiggenhauser, Paul Severin; Friedrich, Daniel; Greve, Jens; Schuler, Patrick J; Hoffmann, Thomas K; Schramm, Alexander

    2017-06-01

    Optimal positioning of bone-anchored implants in the treatment of patients with orbital prosthesis is challenging. The definition of implant axis as well as the positioning of the implants is important to prevent failures in prosthetic rehabilitation in these patients. We performed virtual planning of enossal implants at a base of a standard fan beam CT scan using the software CoDiagnostiX™ (DentalWings, Montréal, Canada). By 3D-printing a surgical guide for drilling and implant insertion was manufactured (Med-610™, Stratasys, Rehovot, Israel). An orbital exenteration was performed in a patient after shrinkage of the eyelids 20 years after enucleation and radiation of the orbit due to rhabdomyosarcoma. 4 Vistafix-3 implants (Cochlear™, Cochlea, Centennial, USA) were primarily inserted after resection with the help of the 3D-surgical guide. Prosthetic rehabilitation could be achieved as preplanned to a predictable result. The individual prosthesis of the orbit showed good functional and esthetic outcome. The virtual 3D-planning of endosseous implants for prosthetic orbital and periorbital reconstruction is easy to use and facilitates optimal placement of implants especially in posttherapeutically altered anatomic situations. © Georg Thieme Verlag KG Stuttgart · New York.

  15. Development of inexpensive prosthetic feet for high-heeled shoes using simple shoe insole model.

    Science.gov (United States)

    Meier, Margrit R; Tucker, Kerice A; Hansen, Andrew H

    2014-01-01

    The large majority of prosthetic feet are aimed at low-heeled shoes, with a few models allowing a heel height of up to 5 cm. However, a survey by the American Podiatric Medical Association indicates that most women wear heels over 5 cm; thus, current prosthetic feet limit most female prosthesis users in their choice. Some prosthetic foot components are heel-height adjustable; however, their plantar surface shapes do not change to match the insole shapes of the shoes with different heel heights. The aims of the study were therefore (1) to develop a model that allows prediction of insole shape for various heel height shoes in combination with different shoe sizes and (2) to develop and field-test low-cost prototypes of prosthetic feet whose insole shapes were based on the new model. An equation was developed to calculate insole shapes independent of shoe size. Field testing of prototype prosthetic feet fabricated based on the equation was successful and demonstrated the utility of the equation.

  16. Development of a prototype over-actuated biomimetic prosthetic hand.

    Directory of Open Access Journals (Sweden)

    Matthew R Williams

    Full Text Available The loss of a hand can greatly affect quality of life. A prosthetic device that can mimic normal hand function is very important to physical and mental recuperation after hand amputation, but the currently available prosthetics do not fully meet the needs of the amputee community. Most prosthetic hands are not dexterous enough to grasp a variety of shaped objects, and those that are tend to be heavy, leading to discomfort while wearing the device. In order to attempt to better simulate human hand function, a dexterous hand was developed that uses an over-actuated mechanism to form grasp shape using intrinsic joint mounted motors in addition to a finger tendon to produce large flexion force for a tight grip. This novel actuation method allows the hand to use small actuators for grip shape formation, and the tendon to produce high grip strength. The hand was capable of producing fingertip flexion force suitable for most activities of daily living. In addition, it was able to produce a range of grasp shapes with natural, independent finger motion, and appearance similar to that of a human hand. The hand also had a mass distribution more similar to a natural forearm and hand compared to contemporary prosthetics due to the more proximal location of the heavier components of the system. This paper describes the design of the hand and controller, as well as the test results.

  17. Prosthetic Hip Loosening Due to Brucellar Infection: Case Report and Literature Review

    Directory of Open Access Journals (Sweden)

    Anis Tebourbi

    2016-12-01

    Full Text Available Context: Brucellosis is actually considered to be the commonest zoonotic infection worldwide; conversely prosthetic infection due to brucella is extremely rare. Although diagnostic is easily achieved, management of such situations is extremely challenging. Aims: To report the case of prosthetic hip loosening due to brucellar infection, discuss management manners and to summarize data about 19 cases reported in the literature. Methods: We report the case of a 73-year-old woman with brucellar prosthetic hip loosening treated with 2-stage exchange of the prosthesis and prolonged double antibiotherapy Results: At two years follow up the patient is pain free with total functional recovery and no clinical and radiographic signs of prosthetic loosening Conclusions: Brucella should be evocated as a cause of total joint arthroplasty infection especially in patients from endemic regions and with occupational exposure. Antibiotic treatment alone can be followed if there are no signs of implant loosening. Tow stage revision should be considered in other cases.

  18. Classification of titanium dioxide

    International Nuclear Information System (INIS)

    Macias B, L.R.; Garcia C, R.M.; Maya M, M.E.; Ita T, A. De; Palacios G, J.

    2002-01-01

    In this work the X-ray diffraction (XRD), Scanning Electron Microscopy (Sem) and the X-ray Dispersive Energy Spectroscopy techniques are used with the purpose to achieve a complete identification of phases and mixture of phases of a crystalline material as titanium dioxide. The problem for solving consists of being able to distinguish a sample of titanium dioxide being different than a titanium dioxide pigment. A standard sample of titanium dioxide with NIST certificate is used, which indicates a purity of 99.74% for the TiO 2 . The following way is recommended to proceed: a)To make an analysis by means of X-ray diffraction technique to the sample of titanium dioxide pigment and on the standard of titanium dioxide waiting not find differences. b) To make a chemical analysis by the X-ray Dispersive Energy Spectroscopy via in a microscope, taking advantage of the high vacuum since it is oxygen which is analysed and if it is concluded that the aluminium oxide appears in a greater proportion to 1% it is established that is a titanium dioxide pigment, but if it is lesser then it will be only titanium dioxide. This type of analysis is an application of the nuclear techniques useful for the tariff classification of merchandise which is considered as of difficult recognition. (Author)

  19. Virtual Control of Prosthetic Hand Based on Grasping Patterns and Estimated Force from Semg

    Directory of Open Access Journals (Sweden)

    Zhu Gao-Ke

    2016-01-01

    Full Text Available Myoelectric prosthetic hands aim to serve upper limb amputees. The myoelectric control of the hand grasp action is a kind of real-time or online method. Thus it is of great necessity to carry on a study of online prosthetic hand electrical control. In this paper, the strategy of simultaneous EMG decoding of grasping patterns and grasping force was realized by controlling a virtual multi-degree-freedom prosthetic hand and a real one-degree-freedom prosthetic hand simultaneously. The former realized the grasping patterns from the recognition of the sEMG pattern. The other implemented the grasping force from sEMG force decoding. The results show that the control method is effective and feasible.

  20. Corrosion behaviour and galvanic coupling of titanium and welded titanium in LiBr solutions

    International Nuclear Information System (INIS)

    Blasco-Tamarit, E.; Igual-Munoz, A.; Garcia Anton, J.; Garcia-Garcia, D.

    2007-01-01

    Corrosion resistance and galvanic coupling of Grade 2 commercially pure titanium in its welded and non-welded condition were systematically analyzed in LiBr solutions. Galvanic corrosion was evaluated through two different methods: anodic polarization (according to the Mixed Potential Theory) and electrochemical noise (using a zero-resistance ammeter). Samples have been etched to study the microstructure. The action of lithium chromate as corrosion inhibitor has been evaluated. Titanium and welded titanium showed extremely low corrosion current densities and elevated pitting potential values (higher than 1 V). The results of both methods, anodic polarization and electrochemical noise, showed that the welded titanium was always the anodic element of the pair titanium-welded titanium, so that its corrosion resistance decreases due to the galvanic effect

  1. Electrowinning molten titanium from titanium dioxide

    CSIR Research Space (South Africa)

    Van Vuuren, DS

    2005-10-01

    Full Text Available the Manufacturing and Materials Industry in it quest for global competitiveness CSIR Manufacturing and Materials Technology 3 Rationale – Titanium Cost Build-up Material Cost Ilmenite $0.27/kg Ti sponge Titanium slag $0.75/kg Ti Sponge TiCl4 and TiO2 $3....10/kg Ti Sponge Ti Sponge raw materials costs $5.50/kg Ti Sponge Total Ti Sponge cost $9-$11/kg Ti Sponge Ti ingot $15-17/kg Ti Aluminium $1.7/kg Al Supporting the Manufacturing and Materials Industry in its quest for global competitivenessorting...

  2. Remote transient Lactobacillus animalis bacteremia causing prosthetic hip joint infection: a case report

    Directory of Open Access Journals (Sweden)

    R. Somayaji

    2016-11-01

    Full Text Available Abstract Background Lactobacillus spp. are uncommon pathogens in immunocompetent hosts, and even rarer causes of prosthetic device infections. Case presentation A case of chronic hip prosthetic joint infection (PJI caused by L. animalis is described. This occurred 5 years after a transient bacteremia with the same organism. Whole genome sequencing of both isolates proved this PJI infection resulted from this remote bacteremia. Conclusions We document that prosthetic joint infections may be a consequence of bacteremia as much as 3 years before the onset of symptoms.

  3. In vitro adherence of bacteria to prosthetic grafting materials

    International Nuclear Information System (INIS)

    Brewer, A.R.; Stromberg, B.V.

    1990-01-01

    Adherence of bacteria to prosthetic grafting material is thought to play an important role in the ultimate development of prosthetic infections. To evaluate the role of bacterial adherence in the initiation and colonization of prosthetic materials, Proplast II, Gore-Tex, and silicone were evaluated for adherence of Escherichia coli and Staphylococcus aureus. Bacteria were radiolabeled and incubated with the study material. Adherence was determined by scintillation. Adherence to Proplast II and Gore-Tex reached a maximum at approximately 45 minutes of incubation and demonstrated a detachment phenomenon with E. coli. Similar results were noted with S. aureus, but with a maximal attachment at approximately 30 minutes. Interestingly, bacterial attachment to silicone continued to increase throughout the time of the incubation. In addition, adherence of S. aureus was at a faster rate than E. coli. Attachment of bacteria is a multifactorial process. However, the PTFE graft demonstrates a slower rate of attachment, lower total number of attached bacteria, and faster detachment. The importance of this phenomenon may help explain the foreign body effect of increased susceptibility to infection of foreign materials

  4. Exophiala (Wangiella dermatitidis Prosthetic Aortic Valve Endocarditis and Prosthetic Graft Infection in an Immune Competent Patient

    Directory of Open Access Journals (Sweden)

    Jay S. Berger

    2017-01-01

    Full Text Available Exophiala (Wangiella dermatitidis is an emerging dematiaceous fungus associated with high mortality rates and is a rare cause of endocarditis. We describe the first case of E. dermatitidis endocarditis of a prosthetic aortic valve and aortic graft in an immune competent patient with no clear risk factors of hematological acquisition.

  5. Combined computed tomography and fluorodeoxyglucose positron emission tomography in the diagnosis of prosthetic valve endocarditis: a case series.

    Science.gov (United States)

    Bartoletti, Michele; Tumietto, Fabio; Fasulo, Giovanni; Giannella, Maddalena; Cristini, Francesco; Bonfiglioli, Rachele; Raumer, Luigi; Nanni, Cristina; Sanfilippo, Silvia; Di Eusanio, Marco; Scotton, Pier Giorgio; Graziosi, Maddalena; Rapezzi, Claudio; Fanti, Stefano; Viale, Pierluigi

    2014-01-13

    The diagnosis of prosthetic valve endocarditis is challenging. The gold standard for prosthetic valve endocarditis diagnosis is trans-esophageal echocardiography. However, trans-esophageal echocardiography may result in negative findings or yield images difficult to differentiate from thrombus in patients with prosthetic valve endocarditis. Combined computed tomography and fluorodeoxyglucose positron emission tomography is a potentially promising diagnostic tool for several infectious conditions and it has also been employed in patients with prosthetic valve endocarditis but data are still scant. We reviewed the charts of 6 patients with prosthetic aortic valves evaluated for suspicion of prosthetic valve endocarditis, at two different hospital, over a 3-year period. We found 3 patients with early-onset PVE cases and blood cultures yielding Pseudomonas aeruginosa, Staphylococcus epidermidis and Staphylococcus lugdunensis, respectively; and 3 late-onset cases in the remaining 3 patients with isolation in the blood of Streptococcus bovis, Candida albicans and P. aeruginosa, respectively. Initial trans-esophageal echocardiography was negative in all the patients, while fluorodeoxyglucose positron emission tomography showed images suspicious for prosthetic valve endocarditis. In 4 out of 6 patients valve replacement was done with histology confirming the prosthetic valve endocarditis diagnosis. After an adequate course of antibiotic therapy fluorodeoxyglucose positron emission tomography showed resolution of prosthetic valve endocarditis in all the patients. Our experience confirms the potential role of fluoroseoxyglucose positron emission tomography in the diagnosis and follow-up of prosthetic valve endocarditis.

  6. Diagnostic performance of FDG PET or PET/CT in prosthetic infection after arthroplasty: a meta-analysis

    International Nuclear Information System (INIS)

    Jin, H.; Yuan, L.; Li, C.; Kan, Y.; Yang, J.; Hao, R.

    2014-01-01

    The purpose of this study was to systematically review and perform a meta-analysis of published data regarding the diagnostic performance of positron emission tomography (PET) or PET/computed tomography (PET/CT) in prosthetic infection after arthroplasty. A comprehensive computer literature search of studies published through May 31, 2012 regarding PET or PET/CT in patients suspicious of prosthetic infection was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of PET or PET/CT in patients suspicious of prosthetic infection on a per prosthesis-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of PET or PET/CT in patients with suspicious of prosthetic infection. Fourteen studies comprising 838 prosthesis with suspicious of prosthetic infection after arthroplasty were included in this meta-analysis. The pooled sensitivity of PET or PET/CT in detecting prosthetic infection was 86% (95% confidence interval [CI] 82-90%) on a per prosthesis-based analysis. The pooled specificity of PET or PET/CT in detecting prosthetic infection was 86% (95% CI 83-89%) on a per prosthesis-based analysis. The area under the ROC curve was 0.93 on a per prosthesis-based analysis. In patients suspicious of prosthetic infection, FDG PET or PET/CT demonstrated high sensitivity and specificity. FDG PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false positive results and influcing factors should kept in mind.

  7. Diagnostic performance of FDG PET or PET/CT in prosthetic infection after arthroplasty: a meta-analysis.

    Science.gov (United States)

    Jin, H; Yuan, L; Li, C; Kan, Y; Hao, R; Yang, J

    2014-03-01

    The purpose of this study was to systematically review and perform a meta-analysis of published data regarding the diagnostic performance of positron emission tomography (PET) or PET/computed tomography (PET/CT) in prosthetic infection after arthroplasty. A comprehensive computer literature search of studies published through May 31, 2012 regarding PET or PET/CT in patients suspicious of prosthetic infection was performed in PubMed/MEDLINE, Embase and Scopus databases. Pooled sensitivity and specificity of PET or PET/CT in patients suspicious of prosthetic infection on a per prosthesis-based analysis were calculated. The area under the receiver-operating characteristic (ROC) curve was calculated to measure the accuracy of PET or PET/CT in patients with suspicious of prosthetic infection. Fourteen studies comprising 838 prosthesis with suspicious of prosthetic infection after arthroplasty were included in this meta-analysis. The pooled sensitivity of PET or PET/CT in detecting prosthetic infection was 86% (95% confidence interval [CI] 82-90%) on a per prosthesis-based analysis. The pooled specificity of PET or PET/CT in detecting prosthetic infection was 86% (95% CI 83-89%) on a per prosthesis-based analysis. The area under the ROC curve was 0.93 on a per prosthesis-based analysis. In patients suspicious of prosthetic infection, FDG PET or PET/CT demonstrated high sensitivity and specificity. FDG PET or PET/CT are accurate methods in this setting. Nevertheless, possible sources of false positive results and influcing factors should kept in mind.

  8. Rapidly growing non-tuberculous mycobacteria infection of prosthetic knee joints: A report of two cases.

    Science.gov (United States)

    Kim, Manyoung; Ha, Chul-Won; Jang, Jae Won; Park, Yong-Beom

    2017-08-01

    Non-tuberculous mycobacteria (NTM) cause prosthetic knee joint infections in rare cases. Infections with rapidly growing non-tuberculous mycobacteria (RGNTM) are difficult to treat due to their aggressive clinical behavior and resistance to antibiotics. Infections of a prosthetic knee joint by RGNTM have rarely been reported. A standard of treatment has not yet been established because of the rarity of the condition. In previous reports, diagnoses of RGNTM infections in prosthetic knee joints took a long time to reach because the condition was not suspected, due to its rarity. In addition, it is difficult to identify RGNTM in the lab because special identification tests are needed. In previous reports, after treatment for RGNTM prosthetic infections, knee prostheses could not be re-implanted in all cases but one, resulting in arthrodesis or resection arthroplasty; this was most likely due to the aggressiveness of these organisms. In the present report, two cases of prosthetic knee joint infection caused by RGNTM (Mycobacterium abscessus) are described that were successfully treated, and in which prosthetic joints were finally reimplanted in two-stage revision surgery. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Dutch evidence-based guidelines for amputation and prosthetics of the lower extremity : Rehabilitation process and prosthetics. Part 2

    NARCIS (Netherlands)

    Geertzen, Jan; van der Linde, Harmen; Rosenbrand, Kitty; Conradi, Marcel; Deckers, Jos; Koning, Jan; Rietman, Hans S.; van der Schaaf, Dick; van der Ploeg, Rein; Schapendonk, Johannes; Schrier, Ernst; Duijzentkunst, Rob Smit; Spruit-van Eijk, Monica; Versteegen, Gerbrig; Voesten, Harrie

    2015-01-01

    Background: A structured, multidisciplinary approach in the rehabilitation process after amputation is needed that includes a greater focus on the involvement of both (para)medics and prosthetists. There is considerable variation in prosthetic prescription concerning the moment of initial prosthesis

  10. Plasmonic Titanium Nitride Nanostructures via Nitridation of Nanopatterned Titanium Dioxide

    DEFF Research Database (Denmark)

    Guler, Urcan; Zemlyanov, Dmitry; Kim, Jongbum

    2017-01-01

    Plasmonic titanium nitride nanostructures are obtained via nitridation of titanium dioxide. Nanoparticles acquired a cubic shape with sharper edges following the rock-salt crystalline structure of TiN. Lattice constant of the resulting TiN nanoparticles matched well with the tabulated data. Energy...

  11. Quality of life after maxillectomy and prosthetic obturator rehabilitation.

    Science.gov (United States)

    Chigurupati, Radhika; Aloor, Neelam; Salas, Richard; Schmidt, Brian L

    2013-08-01

    Surgical resection of midface neoplasms and subsequent reconstruction have been shown to have significant negative effects on quality of life (QOL). The purpose of this pilot study was to assess individuals' health-related QOL after maxillectomy and reconstruction with a prosthetic obturator. The QOL of 25 of 43 patients who underwent maxillectomy and prosthetic obturator reconstruction at the University of California-San Francisco was assessed using 3 questionnaires: University of Washington Quality of Life version 4 (UWQOL), Obturator Functioning Scale (OFS), and Mental Health Inventory (MHI). The response rate to the QOL questionnaires was 92% (23 of 25 patients). Time elapsed from maxillectomy and prosthetic obturator reconstruction to the QOL survey response ranged from 0.3 to 6.6 years (mean, 2.7 years; standard deviation [SD], 1.9 years). The post-treatment mean QOL scores were 77.3 (SD, 13.6) for UWQOL, 72.0 (SD, 12.6) for OFS, and 4.5 (SD, 0.9) for Mental Health Inventory. Individuals who received adjuvant radiation scored lower for speech and appearance (OFS, P = .05, P = .03, respectively) as well as for saliva and overall QOL (UWQOL, P = .02, P = .08, respectively). There was a strong correlation between QOL scores in OFS and UWQOL questionnaires (r = 0.78, P maxillectomy and prosthetic obturator reconstruction. There is further need for a multicenter trial with a larger sample to identify how factors affecting QOL of patients after maxillectomy might influence the choice of reconstruction. Copyright © 2013 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  12. A Statistical Perspective on Running with Prosthetic Lower-Limbs: An Advantage or Disadvantage?

    Directory of Open Access Journals (Sweden)

    Hossein Hassani

    2014-11-01

    Full Text Available Technological developments have led to the increased use of carbon fiber and prosthetic lower-limbs in running events at the Paralympic Games. This study aims to exploit a series of statistical techniques in order to prepare a response to the vital question of whether utilizing prosthetic feet can affect an athletes ability when running competitively at the Paralympics Games by comparing both within and between different classifications. The study also considers the differences between running on biological limbs and prosthetic lower-limbs from a mechanical point of view. The results from the male 100 m, 200 m and 400 m at the 2012 London Paralympic Games have been the source of this investigation. The investigation provides statistical evidence to propose that the number of prosthetic limbs used and the structure of such limbs have a significant impact on the outcome of track events at the Paralympic Games.

  13. The use of expanded microporous polytetrafluoroethylene for limb salvage: a preliminary report.

    Science.gov (United States)

    Campbell, C D; Brooks, D H; Webster, M W; Bahnson, H T

    1976-05-01

    Initial laboratory and clinical evaluations of a new prosthetic material, expanded microporous polytetrafluoroethylene (PTFE), for small vessel replacement is promising and encourages further clinical trial. Frequently the autogenous saphenous vein is not available for bypass procedures, and alternative arterial substitutes have not proved reliable for replacement of small vessels. In this study, 15 patients with impending loss of limb and no available saphenous vein underwent revascularization of the lower extremity with expanded microporous PTFE grafts. Thirteen of 15 patients now demonstrate viable extremities with a resulting over-all early patency and limb salvage rate of 87 percent for this series. Follow-up ranges from one to 8 months. Seven patients had diabetes mellitus and eight had atherosclerotic heart disease. Nine grafts crossed the knee joint. In all patients arterial runoff was poor. Six patients had previous femoropopliteal bypasses, five with autogenous veins and one with Dacron velour. Two patients had multiple previous operations that failed, first with autogenous vein and later with fabric grafts. The current limb salvage and patency rate of 87 percent in high-risk patients suggests that expanded PTFE may be the prosthesis of choice when an autogenous vein is not available and possibly an equally good substitute when the venous autograft is available.

  14. Diagnostic flowcharts in osteomyelitis, spondylodiscitis and prosthetic joint infection

    International Nuclear Information System (INIS)

    Jutte, P.; Lazzeri, E.; Sconfienza, L. M.; Cassar-Pullicino, V.; Trampuz, A.; Petrosillo, N.; Signore, A.

    2014-01-01

    Infections of the bone, spine and prosthetic joints are serious and complex conditions to diagnose and to treat. Structured diagnostic workup may very well improve the accuracy and speed of diagnosis, thereby improving the outcome since treatment may very well be more successful and less harmful if timely management is started. Literature shows no uniform advise on diagnosis. The EANM organized a consensus meeting with representatives from the involved disciplines in order to develop common flowcharts for the diagnosis of osteomyelitis, spondylodiscitis and prosthetic joint infections. In this report the proceedings of this consensus meeting, including the proposed flowcharts for diagnosis, are published.

  15. Mobility function of a prosthetic knee joint with an automatic stance phase lock.

    Science.gov (United States)

    Andrysek, Jan; Klejman, Susan; Torres-Moreno, Ricardo; Heim, Winfried; Steinnagel, Bryan; Glasford, Shane

    2011-06-01

    There is a need for a prosthetic knee joint design that is technologically and functionally appropriate for use in developing countries. To develop and clinically evaluate a new type of stance phase controlled prosthetic knee joint that provides stance phase stability without inhibiting swing phase flexion. A crossover repeated measures study design comparing the new knee joint to the participant's conventional low- or high-end prosthetic knee joint. The new knee joint was fitted to fourteen individuals aged 15 to 67 years with unilateral lower limb amputations. Walk tests were performed to measure walking speed. Energy expenditure was estimated using the physiological cost index (PCI). Walking speeds with the new knee joint were on average 0.14 m/s faster than conventional low-end knees (p < 0.0001), but 0.07 m/s slower than conventional high-end prosthetic knees (p = 0.008). The PCI was similar across all three knee joint technologies (p = 0.276). Mobility function with the new knee joint, in terms of walking speed, was more closely matched to high-end than low-end prosthetic knee joints. Therefore, given its relatively simple design, the new stance phase control mechanism may offer a functional and cost effective solution for active transfemoral amputees. This paper describes a new type of prosthetic knee joint mechanism that is intended to be cost-effective while providing high-level stance phase function to active individuals with a transfemoral amputation. Initial clinical testing suggests that the new knee joint may have some functional advantages over existing technologies in this category.

  16. Prosthetics socket that incorporates an air splint system focusing on dynamic interface pressure.

    Science.gov (United States)

    Razak, Nasrul Anuar Abd; Osman, Noor Azuan Abu; Gholizadeh, Hossein; Ali, Sadeeq

    2014-08-01

    The interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. This paper presents the design and performance of a new prosthetic socket that uses an air splint system. The air splint prosthetic socket system was implemented by combining the air splint with a pressure sensor that the transhumeral user controls through the use of a microcontroller. The modular construction of the system developed allows the FSR pressure sensors that are placed inside the air splint socket to determine the required size and fitting for the socket used. Fifteen transhumeral amputees participated in the study. The subject's dynamic pressure on the socket that's applied while wearing the air splint systems was recorded using F-socket transducers and microcontroller analysis. The values collected by the F-socket sensor for the air splint prosthetic socket system were determined accordingly by comparing the dynamic pressure applied using statically socket. The pressure volume of the air splint fluctuated and was recorded at an average of 38 kPa (2.5) to 41 kPa (1.3) over three hours. The air splint socket might reduce the pressure within the interface of residual limb. This is particularly important during the daily life activities and may reduce the pain and discomfort at the residual limb in comparison to the static socket. The potential development of an auto-adjusted socket that uses an air splint system as the prosthetic socket will be of interest to researchers involved in rehabilitation engineering, prosthetics and orthotics.

  17. Artefacts in multimodal imaging of titanium, zirconium and binary titanium-zirconium alloy dental implants: an in vitro study.

    Science.gov (United States)

    Smeets, Ralf; Schöllchen, Maximilian; Gauer, Tobias; Aarabi, Ghazal; Assaf, Alexandre T; Rendenbach, Carsten; Beck-Broichsitter, Benedicta; Semmusch, Jan; Sedlacik, Jan; Heiland, Max; Fiehler, Jens; Siemonsen, Susanne

    2017-02-01

    To analyze and evaluate imaging artefacts induced by zirconium, titanium and titanium-zirconium alloy dental implants. Zirconium, titanium and titanium-zirconium alloy implants were embedded in gelatin and MRI, CT and CBCT were performed. Standard protocols were used for each modality. For MRI, line-distance profiles were plotted to quantify the accuracy of size determination. For CT and CBCT, six shells surrounding the implant were defined every 0.5 cm from the implant surface and histogram parameters were determined for each shell. While titanium and titanium-zirconium alloy induced extensive signal voids in MRI owing to strong susceptibility, zirconium implants were clearly definable with only minor distortion artefacts. For titanium and titanium-zirconium alloy, the MR signal was attenuated up to 14.1 mm from the implant. In CT, titanium and titanium-zirconium alloy resulted in less streak artefacts in comparison with zirconium. In CBCT, titanium-zirconium alloy induced more severe artefacts than zirconium and titanium. MRI allows for an excellent image contrast and limited artefacts in patients with zirconium implants. CT and CBCT examinations are less affected by artefacts from titanium and titanium-zirconium alloy implants compared with MRI. The knowledge about differences of artefacts through different implant materials and image modalities might help support clinical decisions for the choice of implant material or imaging device in the clinical setting.

  18. Development of inexpensive prosthetic feet for high-heeled shoes using simple shoe insole model

    OpenAIRE

    Margrit R. Meier, PhD; Kerice A. Tucker, BSc; Andrew H. Hansen, PhD

    2014-01-01

    The large majority of prosthetic feet are aimed at low-heeled shoes, with a few models allowing a heel height of up to 5 cm. However, a survey by the American Podiatric Medical Association indicates that most women wear heels over 5 cm; thus, current prosthetic feet limit most female prosthesis users in their choice. Some prosthetic foot components are heel-height adjustable; however, their plantar surface shapes do not change to match the insole shapes of the shoes with different heel height...

  19. A global perspective on mechanical prosthetic heart valve thrombosis: Diagnostic and therapeutic challenges

    Science.gov (United States)

    Gürsoy, Mustafa Ozan; Kalçık, Macit; Yesin, Mahmut; Karakoyun, Süleyman; Bayam, Emrah; Gündüz, Sabahattin; Özkan, Mehmet

    2016-01-01

    Prosthetic valve thrombosis is one of the major causes of primary valve failure, which can be life-threatening. Multimodality imaging is necessary for determination of leaflet immobilization, cause of underlying pathology (thrombus versus pannus or both), and whether thrombolytic therapy attempt in the patient would be successful or surgery is needed. Current guidelines for the management of prosthetic valve thrombosis lack definitive class I recommendations due to lack of randomized controlled trials, and usually leave the choice of treatment to the clinician’s experience. In this review, we aimed to summarize the pathogenesis, diagnosis, and management of mechanical prosthetic valve thrombosis. PMID:28005024

  20. Echocardiographic Evaluation of Tricuspid Prosthetic Valves: An Update

    Directory of Open Access Journals (Sweden)

    Dimitrios Maragiannis, MD, FASE, FACC

    2016-05-01

    Full Text Available This review focuses on the diagnostic value of novel echocardiographic techniques and the clinical application of recently described algorithms to assess tricuspid prosthetic valve function.

  1. Prosthetic hip joint infection due to Campylobacter fetus.

    OpenAIRE

    Bates, C J; Clarke, T C; Spencer, R C

    1994-01-01

    A case of postoperative prosthetic hip joint infection due to Campylobacter fetus subsp. fetus is described. Difficulties in isolation and antimicrobial susceptibility testing of this organism are discussed.

  2. Finite element analysis of the contact interface between trans-femoral stump and prosthetic socket.

    Science.gov (United States)

    Zhang, Linlin; Zhu, Ming; Shen, Ling; Zheng, Feng

    2013-01-01

    Transfemoral amputees need prosthetic devices after amputation surgery, and the interface pressure between the residual limb and prosthetic socket has a significant effect on an amputee's satisfaction and comfort. The purpose of this study was to build a nonlinear finite element model to investigate the interface pressure between the above-knee residual limb and its prosthetic socket. The model was three-dimensional (3D) with consideration of nonlinear boundary conditions. Contact analysis was used to simulate the friction conditions between skin and the socket. The normal stresses up to 80.57 kPa at the distal end of the soft tissue. The longitudinal and circumferential shear stress distributions at the limb-socket interface were also simulated. This study explores the influences of load transfer between trans-femoral residual limb and its prosthetic socket.

  3. Experimental measurement of flexion-extension movement in normal and corpse prosthetic elbow joint.

    Science.gov (United States)

    TarniŢă, Daniela; TarniŢă, DănuŢ Nicolae

    2016-01-01

    This paper presents a comparative experimental study of flexion-extension movement in healthy elbow and in the prosthetic elbow joint fixed on an original experimental bench. Measurements were carried out in order to validate the functional morphology and a new elbow prosthesis type ball head. The three-dimensional (3D) model and the physical prototype of our experimental bench used to test elbow endoprosthesis at flexion-extension and pronation-supination movements is presented. The measurements were carried out on a group of nine healthy subjects and on the prosthetic corpse elbow, the experimental data being obtained for flexion-extension movement cycles. Experimental data for the two different flexion-extension tests for the nine subjects and for the corpse prosthetic elbow were acquired using SimiMotion video system. Experimental data were processed statistically. The corresponding graphs were obtained for all subjects in the experimental group, and for corpse prosthetic elbow for both flexion-extension tests. The statistical analysis has proved that the flexion angles of healthy elbows were significantly close to the values measured at the prosthetic elbow fixed on the experimental bench. The studied elbow prosthesis manages to re-establish the mobility for the elbow joint as close to the normal one.

  4. The effect of prosthetic foot push-off on mechanical loading associated with knee osteoarthritis in lower extremity amputees.

    Science.gov (United States)

    Morgenroth, David C; Segal, Ava D; Zelik, Karl E; Czerniecki, Joseph M; Klute, Glenn K; Adamczyk, Peter G; Orendurff, Michael S; Hahn, Michael E; Collins, Steven H; Kuo, Art D

    2011-10-01

    Lower extremity amputation not only limits mobility, but also increases the risk of knee osteoarthritis of the intact limb. Dynamic walking models of non-amputees suggest that pushing-off from the trailing limb can reduce collision forces on the leading limb. These collision forces may determine the peak knee external adduction moment (EAM), which has been linked to the development of knee OA in the general population. We therefore hypothesized that greater prosthetic push-off would lead to reduced loading and knee EAM of the intact limb in unilateral transtibial amputees. Seven unilateral transtibial amputees were studied during gait under three prosthetic foot conditions that were intended to vary push-off. Prosthetic foot-ankle push-off work, intact limb knee EAM and ground reaction impulses for both limbs during step-to-step transition were measured. Overall, trailing limb prosthetic push-off work was negatively correlated with leading intact limb 1st peak knee EAM (slope=-.72±.22; p=.011). Prosthetic push-off work and 1st peak intact knee EAM varied significantly with foot type. The prosthetic foot condition with the least push-off demonstrated the largest knee EAM, which was reduced by 26% with the prosthetic foot producing the most push-off. Trailing prosthetic limb push-off impulse was negatively correlated with leading intact limb loading impulse (slope=-.34±.14; p=.001), which may help explain how prosthetic limb push-off can affect intact limb loading. Prosthetic feet that perform more prosthetic push-off appear to be associated with a reduction in 1st peak intact knee EAM, and their use could potentially reduce the risk and burden of knee osteoarthritis in this population. Published by Elsevier B.V.

  5. Innovación en la reconstrucción del pabellón auricular disgenésico con tejido expandido e implante Innovation in congenital auricular anomaly reconstruction using expanded tissue and prosthetic material

    Directory of Open Access Journals (Sweden)

    P. Iwanyk

    2007-06-01

    Full Text Available En la reconstrucción de un pabellón auricular disgenésico se plantean, básicamente, dos desafíos, reproducir un esqueleto cartilaginoso auricular de forma, tamaño y proyección similar al pabellón auricular normal, y obtener piel suficiente que combine color, textura y grosor semejante a la circundante. Debido a la escasa cantidad de piel útil en esta localización y a la dificultad en el tallado del esqueleto cartilaginoso auricular, iniciamos en 2005 en nuestro Hospital la reconstrucción auricular mediante combinación de tejidos expandidos locales y materiales protésicos, logrando un excelente resultado de apariencia natural.Reconstruction of congenital auricular anomalies includes two essential challenges. The first one is to sculpt an auricular cartilaginous structure that matches the shape, size and projection of a standard ear. The second challenge arises from the scarcity of the usable skin in the area. Because of the difficulty of sculpting a proper cartilage framework and the scarce quantity of skin in the area, in 2005 we began in our hospital auricular reconstruction procedure combining tissue expanders and prosthetic materials achieving a natural appearance and an excellent result.

  6. Prosthetic valves in adult patients with congenital heart disease : Rationale and design of the Dutch PROSTAVA study

    NARCIS (Netherlands)

    Freling, H. G.; van Slooten, Y. J.; van Melle, J. P.; Mulder, B. J. M.; van Dijk, A. P. J.; Hillege, H. L.; Post, M. C.; Sieswerda, G. Tj; Jongbloed, M. R. M.; Willems, T. P.; Pieper, P. G.

    2012-01-01

    Data on long-term complications in adult patients with congenital heart disease (ACHD) and a prosthetic valve are scarce. Moreover, the influence of prosthetic valves on quality of life (QoL) and functional outcome in ACHD patients with prosthetic valves has not been studied. The primary objective

  7. Advances for prosthetic technology from historical perspective to current status to future application

    CERN Document Server

    LeMoyne, Robert

    2016-01-01

    This book focuses on the advances in transtibial prosthetic technology and targets research in the evolution of the powered prosthesis such as the BiOM, which was derived from considerable research and development at the Massachusetts Institute of Technology. The concept of the book spans the historical evolution of prosthetic applications from passive to new and futuristic robotic prosthetic technologies.  The author describes the reasons for amputation, surgical procedures, and an historical perspective of the prosthesis for the lower limb. He also addresses the phases and sub-phases of gait and compensatory mechanisms arising for a transtibial prosthesis and links the compensatory mechanisms to long-term morbidities.  The general technologies for gait analysis central to prosthetic design and the inherent biomechanics foundations for analysis are also explored.  The book reports on recent-past to current-term applications with passive elastic prostheses.  The core of the book deals with futuristic robo...

  8. Multimodality Imaging Assessment of Prosthetic Heart Valves

    NARCIS (Netherlands)

    Suchá, D.; Symersky, Petr; Tanis, W; Mali, Willem P Th M; Leiner, Tim; van Herwerden, LA; Budde, Ricardo P J

    Echocardiography and fluoroscopy are the main techniques for prosthetic heart valve (PHV) evaluation, but because of specific limitations they may not identify the morphological substrate or the extent of PHV pathology. Cardiac computed tomography (CT) and magnetic resonance imaging (MRI) have

  9. Rough surfaces of titanium and titanium alloys for implants and prostheses

    International Nuclear Information System (INIS)

    Conforto, E.; Aronsson, B.-O.; Salito, A.; Crestou, C.; Caillard, D.

    2004-01-01

    Titanium and titanium alloys for dental implants and hip prostheses were surface-treated and/or covered by metallic or ceramic rough layers after being submitted to sand blasting. The goal of these treatments is to improve the surface roughness and consequently the osteointegration, the fixation, and the stability of the implant. The microstructure of titanium and titanium alloys submitted to these treatments has been studied and correlated to their mechanical behavior. As-treated/covered and mechanically tested surfaces were characterized by scanning electron microscopy (SEM). Structural analyses performed by transmission electron microscopy (TEM), mainly in cross-section, reveal the degree of adherence and cohesion between the surface layer and the substrate (implant). We observed that, although the same convenient surface roughness was obtained with the two types of process, many characteristics as structural properties and mechanical behavior are very different

  10. Distortion of CAD-CAM-fabricated implant-fixed titanium and zirconia complete dental prosthesis frameworks.

    Science.gov (United States)

    Al-Meraikhi, Hadi; Yilmaz, Burak; McGlumphy, Edwin; Brantley, William A; Johnston, William M

    2018-01-01

    Computer-aided design and computer-aided manufacturing (CAD-CAM)-fabricated titanium and zirconia implant-supported fixed dental prostheses have become increasingly popular for restoring patients with complete edentulism. However, the distortion level of these frameworks is not well known. The purpose of this in vitro study was to compare the 3-dimensional (3D) distortion of CAD-CAM zirconia and titanium implant-fixed screw-retained complete dental prostheses. A master edentulous model with 4 implants at the positions of the maxillary first molars and canines was used. Multiunit abutments (Nobel Biocare) secured to the model were digitally scanned using scan bodies and a laboratory scanner (S600 ARTI; Zirkonzahn). Titanium (n=5) and zirconia (n=5) frameworks were milled using a CAD-CAM system (Zirkonzahn M1; Zirkonzahn). All frameworks were scanned using an industrial computed tomography (CT) scanner (Nikon/X-Tek XT H 225kV MCT Micro-Focus). The direct CT scans were reconstructed to generate standard tessellation language (STL) files. To calculate the 3D distortion of the frameworks, STL files of the CT scans were aligned to the CAD model using a sum of the least squares best-fit algorithm. Surface comparison points were placed on the CAD model on the midfacial aspect of all teeth. The 3D distortion of each direct scan to the CAD model was calculated. In addition, color maps of the scan-to-CAD comparison were constructed using a ±0.500 mm color scale range. Both materials exhibited distortion; however, no significant difference was found in the amount of distortion from the CAD model between the materials (P=.747). Absolute values of deviations from the CAD model were evident in the x and y plane and less so in the z direction. Zirconia and titanium frameworks showed similar 3D distortion compared with the CAD model for the tested CAD-CAM and implant systems. The distortion was more pronounced in the horizontal and sagittal plane than in the vertical plane

  11. Prosthetic Joint Infection

    Science.gov (United States)

    Tande, Aaron J.

    2014-01-01

    SUMMARY Prosthetic joint infection (PJI) is a tremendous burden for individual patients as well as the global health care industry. While a small minority of joint arthroplasties will become infected, appropriate recognition and management are critical to preserve or restore adequate function and prevent excess morbidity. In this review, we describe the reported risk factors for and clinical manifestations of PJI. We discuss the pathogenesis of PJI and the numerous microorganisms that can cause this devastating infection. The recently proposed consensus definitions of PJI and approaches to accurate diagnosis are reviewed in detail. An overview of the treatment and prevention of this challenging condition is provided. PMID:24696437

  12. Can We Achieve Intuitive Prosthetic Elbow Control Based on Healthy Upper Limb Motor Strategies?

    Directory of Open Access Journals (Sweden)

    Manelle Merad

    2018-02-01

    Full Text Available Most transhumeral amputees report that their prosthetic device lacks functionality, citing the control strategy as a major limitation. Indeed, they are required to control several degrees of freedom with muscle groups primarily used for elbow actuation. As a result, most of them choose to have a one-degree-of-freedom myoelectric hand for grasping objects, a myoelectric wrist for pronation/supination, and a body-powered elbow. Unlike healthy upper limb movements, the prosthetic elbow joint angle, adjusted prior to the motion, is not involved in the overall upper limb movements, causing the rest of the body to compensate for the lack of mobility of the prosthesis. A promising solution to improve upper limb prosthesis control exploits the residual limb mobility: like in healthy movements, shoulder and prosthetic elbow motions are coupled using inter-joint coordination models. The present study aims to test this approach. A transhumeral amputated individual used a prosthesis with a residual limb motion-driven elbow to point at targets. The prosthetic elbow motion was derived from IMU-based shoulder measurements and a generic model of inter-joint coordinations built from healthy individuals data. For comparison, the participant also performed the task while the prosthetic elbow was implemented with his own myoelectric control strategy. The results show that although the transhumeral amputated participant achieved the pointing task with a better precision when the elbow was myoelectrically-controlled, he had to develop large compensatory trunk movements. Automatic elbow control reduced trunk displacements, and enabled a more natural body behavior with synchronous shoulder and elbow motions. However, due to socket impairments, the residual limb amplitudes were not as large as those of healthy shoulder movements. Therefore, this work also investigates if a control strategy whereby prosthetic joints are automatized according to healthy individuals

  13. Radiological visualization of prosthetic heart valves in situ

    International Nuclear Information System (INIS)

    Hoffmeister, H.M.; Pirschel, J.

    1986-01-01

    To determine the radiographic appearance of prosthetic heart valves 15 different models were investigated in situ. Fluoroscopy with detail radiographs and standard chest-radiographs were used for identification of the specific type of the prosthesis, for determination of details of the valve apparatus and for evaluation of the motion of the valve disc/ball. - Fluoroscopy and routine radiographs provided sufficient information to identify all prosthetic heart valves with exception of the Xenomedica bioprosthesis. If radiopaque material was used for the valve disc/ball, fluoroscopic assessment of the function of the valve was possible. Thus, in most types of disc or ball valves the opening/closing of the valve can be visualized, whereas in bioprosthesis a radiological determination of the mechanical function is not possible. (orig.) [de

  14. Case study: survey of patient satisfaction with prosthesis quality and design among below-knee prosthetic leg socket users.

    Science.gov (United States)

    Mohd Hawari, Nurhanisah; Jawaid, Mohammad; Md Tahir, Paridah; Azmeer, Raja Ahmad

    2017-11-01

    The aim of this case study was to explore patient satisfaction with the quality of prosthetic leg sockets intended for persons with lower limb amputations. A qualitative study based on in-depth interviews, preceded by a questionnaire session, was carried out with patients from the Rehabilitation Center and Hospital in Malaysia. Twelve out-patient and in-patient amputees with lower limb amputations, specifically below-knee amputations, were chosen randomly. The analysis of patients' narratives aimed to identify the functional and esthetic characteristics of currently used prosthetic leg sockets and any problems related to them. The obtained results indicated that out of the 12 participants, 41.7% and 25% were satisfied and somewhat satisfied with their current prosthetic sockets. Durability and comfort were rated by the participants as the most important characteristics of prosthetic sockets, with 83.3%. As regards the esthetic appearance of the socket, 66.7% of the respondents considered that the most important feature was the material from which the socket was fabricated. Thus, we conclude that current satisfaction levels with the quality of prosthetic sockets among amputees in Malaysia are suitable, prosthesis being preferred by many amputees. The results can be used to direct future research on cosmesis and functionality of prosthetic socket design. Implications for Rehabilitation Case study will help participants to get cost effective prosthetic leg socket. Develop prosthetic leg socket comfortable as comparative to existing one. Help Malaysian government to make policy to develop local prosthetic leg socket at affordable price.

  15. Factors influencing the cost of prosthetic joint infection treatment.

    Science.gov (United States)

    Peel, T N; Cheng, A C; Lorenzo, Y P; Kong, D C M; Buising, K L; Choong, P F M

    2013-11-01

    Prosthetic joint infection (PJI) is associated with significant costs to the healthcare system. Current literature examines the cost of specific treatment modalities without assessing other cost drivers for PJI. To examine the overall cost of the treatment of PJI and to identify factors associated with management costs. The costs of treatment of prosthetic joint infections were examined in 139 patients across 10 hospitals over a 3-year period (January 2006 to December 2008). Cost calculations included hospitalization costs, surgical costs, hospital-in-the-home costs and antibiotic therapy costs. Negative binomial regression analysis was performed to model factors associated with total cost. The median cost of treating prosthetic joint infection per patient was Australian $34,800 (interquartile range: 20,305, 56,929). The following factors were associated with increased treatment costs: septic revision arthroplasty (67% increase in treatment cost; P = 0.02), hypotension at presentation (70% increase; P = 0.03), polymicrobial infections (41% increase; P = 0.009), surgical treatment with one-stage exchange (100% increase; P = 0.002) or resection arthroplasty (48% increase; P = 0.001) were independently associated with increased treatment costs. Culture-negative prosthetic joint infections were associated with decreased costs (29% decrease in treatment cost; P = 0.047). Treatment failure was associated with 156% increase in treatment costs. This study identifies clinically important factors influencing treatment costs that may be of relevance to policy-makers, particularly in the setting of hospital reimbursement and guiding future research into cost-effective preventive strategies. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  16. Increased risk of prosthetic joint infection associated with esophago-gastro-duodenoscopy with biopsy.

    Science.gov (United States)

    Coelho-Prabhu, Nayantara; Oxentenko, Amy S; Osmon, Douglas R; Baron, Todd H; Hanssen, Arlen D; Wilson, Walter R; Steckelberg, James M; Baddour, Larry M; Harmsen, William S; Mandrekar, Jay; Berbari, Elie F

    2013-02-01

    There are no prospective data regarding the risk of prosthetic joint infection following routine gastrointestinal endoscopic procedures. We wanted to determine the risk of prosthetic hip or knee infection following gastrointestinal endoscopic procedures in patients with joint arthroplasty. We conducted a prospective, single-center, case-control study at a single, tertiary-care referral center. Cases were defined as adult patients hospitalized for prosthetic joint infection of the hip or knee between December 1, 2001 and May 31, 2006. Controls were adult patients with hip or knee arthroplasties but without a diagnosis of joint infection, hospitalized during the same time period at the same orthopedic hospital. The main outcome measure was the odds ratio (OR) of prosthetic joint infection after gastrointestinal endoscopic procedures performed within 2 years before admission. 339 cases and 339 controls were included in the study. Of these, 70 cases (21%) cases and 82 controls (24%) had undergone a gastrointestinal endoscopic procedure in the preceding 2 years. Among gastrointestinal procedures that were assessed, esophago-gastro-duodenoscopy (EGD) with biopsy was associated with an increased risk of prosthetic joint infection (OR = 3, 95% CI: 1.1-7). In a multivariable analysis adjusting for sex, age, joint age, immunosuppression, BMI, presence of wound drain, prior arthroplasty, malignancy, ASA score, and prothrombin time, the OR for infection after EGD with biopsy was 4 (95% CI: 1.5-10). EGD with biopsy was associated with an increased risk of prosthetic joint infection in patients with hip or knee arthroplasties. This association will need to be confirmed in other epidemiological studies and adequately powered prospective clinical trials prior to recommending antibiotic prophylaxis in these patients.

  17. A smartphone photogrammetry method for digitizing prosthetic socket interiors.

    Science.gov (United States)

    Hernandez, Amaia; Lemaire, Edward

    2017-04-01

    Prosthetic CAD/CAM systems require accurate 3D limb models; however, difficulties arise when working from the person's socket since current 3D scanners have difficulties scanning socket interiors. While dedicated scanners exist, they are expensive and the cost may be prohibitive for a limited number of scans per year. A low-cost and accessible photogrammetry method for socket interior digitization is proposed, using a smartphone camera and cloud-based photogrammetry services. 15 two-dimensional images of the socket's interior are captured using a smartphone camera. A 3D model is generated using cloud-based software. Linear measurements were comparing between sockets and the related 3D models. 3D reconstruction accuracy averaged 2.6 ± 2.0 mm and 0.086 ± 0.078 L, which was less accurate than models obtained by high quality 3D scanners. However, this method would provide a viable 3D digital socket reproduction that is accessible and low-cost, after processing in prosthetic CAD software. Clinical relevance The described method provides a low-cost and accessible means to digitize a socket interior for use in prosthetic CAD/CAM systems, employing a smartphone camera and cloud-based photogrammetry software.

  18. Prosthetic Leg Control in the Nullspace of Human Interaction.

    Science.gov (United States)

    Gregg, Robert D; Martin, Anne E

    2016-07-01

    Recent work has extended the control method of virtual constraints, originally developed for autonomous walking robots, to powered prosthetic legs for lower-limb amputees. Virtual constraints define desired joint patterns as functions of a mechanical phasing variable, which are typically enforced by torque control laws that linearize the output dynamics associated with the virtual constraints. However, the output dynamics of a powered prosthetic leg generally depend on the human interaction forces, which must be measured and canceled by the feedback linearizing control law. This feedback requires expensive multi-axis load cells, and actively canceling the interaction forces may minimize the human's influence over the prosthesis. To address these limitations, this paper proposes a method for projecting virtual constraints into the nullspace of the human interaction terms in the output dynamics. The projected virtual constraints naturally render the output dynamics invariant with respect to the human interaction forces, which instead enter into the internal dynamics of the partially linearized prosthetic system. This method is illustrated with simulations of a transfemoral amputee model walking with a powered knee-ankle prosthesis that is controlled via virtual constraints with and without the proposed projection.

  19. Ergonomic workplace assessment in orthotic and prosthetic workshops.

    Science.gov (United States)

    Salmani Nodooshan, H; Koohi Booshehri, S; Daneshmandi, H; Choobineh, A R

    2016-10-17

    In Iranian orthotic and prosthetic workshops, the majority of activities are carried out by manpower and the tasks are labor-intensive. In these workshops, ergonomic aspects of working conditions are seldom considered. This study was conducted in orthotic and prosthetic workshops with the objectives of determination of prevalence rate of MSDs among employees and assessment of ergonomics working conditions. In this cross-sectional study, all employees (n = 42; 29 males and 13 females) in 11 active orthotic and prosthetic production centers of Shiraz city participated. Data were collected using Nordic Musculoskeletal disorders Questionnaire (NMQ) and observational technique by an ergonomics checklist for assessment of working conditions. The means (SD) of age and job tenure (years) in the study individuals were 37.26 (10.21) and 12.8 (9.39), respectively. The most prevalent MSD symptoms in the past 12 months were reported in the lower back (42.9%), shoulders (40.5%) and knees (40.5%). Working conditions assessment showed that the main ergonomic problems in the workshops studied originated from awkward working posture, improper workstation design, poorly designed hand tools and incorrect manual material handling. Any interventional program for working conditions improvement should, therefore, focus on these areas.

  20. Rapid PMR determination of hydrogen in titanium hydride and dehydrogenated titanium powders

    International Nuclear Information System (INIS)

    Il'enko, V.S.; Demidenko, L.M.

    1987-01-01

    Proton magnetic resonance (PMR) enables determining hydrogen quantitatively in titanium hydride and dehydrogenated titanium powders without destroying the specimen and is also more informative than high-temperature extraction methods. PMR provides data on the electron-nuclear interactions and the activation energies for hydrogen diffusion while also providing conclusions on the forms and positives of the hydrogen in the lattice and the binding to the metal atoms. The authors have developed a rapid method for determining hydrogen in titanium hydride and dehydrogenated titanium powders which reduces the analysis time and improves the metrological characteristics. The authors use a YaMR-5535 spectrometer working at 40 MHz upgraded for use with hydrogen in solids. The authors used specimens of mass about 2 g ground to 0.1 mm powder

  1. The relevance of aortic endograft prosthetic infection

    NARCIS (Netherlands)

    Cernohorsky, Paul; Reijnen, Michel M. P. J.; Tielliu, Ignace F. J.; van Sterkenburg, Steven M. M.; van den Dungen, Jan J. A. M.; Zeebregts, Clark J.

    Background: Vascular prosthetic graft infection is a severe complication after open aortic aneurysm repair. Reports of infected endografts are scarce. General treatment consensus with infected graft material is that it should be removed completely. The objective of this study was to describe the

  2. Good quality of life outcomes after treatment of prosthetic joint infection with debridement and prosthesis retention.

    Science.gov (United States)

    Aboltins, Craig; Dowsey, Michelle; Peel, Trish; Lim, Wen K; Choong, Peter

    2016-05-01

    Patients treated for early prosthetic joint infection (PJI) with surgical debridement and prosthesis retention have a rate of successful infection eradication that is similar to patients treated with the traditional approach of prosthesis exchange. It is therefore important to consider other outcomes after prosthetic joint infection treatment that may influence management decisions, such as quality of life (QOL). Our aim was to describe infection cure rates and quality of life for patients with prosthetic joint infection treated with debridement and prosthesis retention and to determine if treatment with this approach was a risk factor for poor quality of life outcomes. Prospectively collected pre and post-arthroplasty data were available for 2,134 patients, of which PJI occurred in 41. For patients treated for prosthetic joint infection, the 2-year survival free of treatment failure was 87% (95%CI 84-89). Prosthetic joint infection cases treated with debridement and retention had a similar improvement from pre-arthroplasty to 12-months post-arthroplasty as patients without PJI in QOL according to the SF-12 survey. Prosthetic joint infection treated with debridement and retention was not a risk factor for poor quality of life on univariate or multivariate analysis. Prosthetic joint infection treated with debridement and prosthesis retention results in good cure rates and quality of life. Further studies are required that directly compare quality of life for different surgical approaches for prosthetic joint infection to better inform management decisions. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:898-902, 2016. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  3. Overview: Mechanism and Control of a Prosthetic Arm.

    Science.gov (United States)

    Kulkarni, Tushar; Uddanwadiker, Rashmi

    2015-09-01

    Continuous growth in industrialization and lack of awareness in safety parameters the cases of amputations are growing. The search of safer, simpler and automated prosthetic arms for managing upper limbs is expected. Continuous efforts have been made to design and develop prosthetic arms ranging from simple harness actuated to automated mechanisms with various control options. However due the cost constraints, the automated prosthetic arms are still out of the reach of needy people. Recent data have shown that there is a wide scope to develop a low cost and light weight upper limb prosthesis. This review summarizes the various designs methodologies, mechanisms and control system developed by the researchers and the advances therein. Educating the patient to develop acceptability to prosthesis and using the same for the most basic desired functions of human hand, post amputation care and to improve patient's independent life is equally important. In conclusion it can be interpreted that there is a wide scope in design in an adaptive mechanism for opening and closing of the fingers using other methods of path and position synthesis. Simple mechanisms and less parts may optimize the cost factor. Reduction in the weight of the prosthesis may be achieved using polymers used for engineering applications. Control system will remain never ending challenge for the researchers, but it is essential to maintain the simplicity from the patients perspective.

  4. Smartphones as image processing systems for prosthetic vision.

    Science.gov (United States)

    Zapf, Marc P; Matteucci, Paul B; Lovell, Nigel H; Suaning, Gregg J

    2013-01-01

    The feasibility of implants for prosthetic vision has been demonstrated by research and commercial organizations. In most devices, an essential forerunner to the internal stimulation circuit is an external electronics solution for capturing, processing and relaying image information as well as extracting useful features from the scene surrounding the patient. The capabilities and multitude of image processing algorithms that can be performed by the device in real-time plays a major part in the final quality of the prosthetic vision. It is therefore optimal to use powerful hardware yet to avoid bulky, straining solutions. Recent publications have reported of portable single-board computers fast enough for computationally intensive image processing. Following the rapid evolution of commercial, ultra-portable ARM (Advanced RISC machine) mobile devices, the authors investigated the feasibility of modern smartphones running complex face detection as external processing devices for vision implants. The role of dedicated graphics processors in speeding up computation was evaluated while performing a demanding noise reduction algorithm (image denoising). The time required for face detection was found to decrease by 95% from 2.5 year old to recent devices. In denoising, graphics acceleration played a major role, speeding up denoising by a factor of 18. These results demonstrate that the technology has matured sufficiently to be considered as a valid external electronics platform for visual prosthetic research.

  5. ARM-based visual processing system for prosthetic vision.

    Science.gov (United States)

    Matteucci, Paul B; Byrnes-Preston, Philip; Chen, Spencer C; Lovell, Nigel H; Suaning, Gregg J

    2011-01-01

    A growing number of prosthetic devices have been shown to provide visual perception to the profoundly blind through electrical neural stimulation. These first-generation devices offer promising outcomes to those affected by degenerative disorders such as retinitis pigmentosa. Although prosthetic approaches vary in their placement of the stimulating array (visual cortex, optic-nerve, epi-retinal surface, sub-retinal surface, supra-choroidal space, etc.), most of the solutions incorporate an externally-worn device to acquire and process video to provide the implant with instructions on how to deliver electrical stimulation to the patient, in order to elicit phosphenized vision. With the significant increase in availability and performance of low power-consumption smart phone and personal device processors, the authors investigated the use of a commercially available ARM (Advanced RISC Machine) device as an externally-worn processing unit for a prosthetic neural stimulator for the retina. A 400 MHz Samsung S3C2440A ARM920T single-board computer was programmed to extract 98 values from a 1.3 Megapixel OV9650 CMOS camera using impulse, regional averaging and Gaussian sampling algorithms. Power consumption and speed of video processing were compared to results obtained to similar reported devices. The results show that by using code optimization, the system is capable of driving a 98 channel implantable device for the restoration of visual percepts to the blind.

  6. Dynamic elasticity measurement for prosthetic socket design.

    Science.gov (United States)

    Kim, Yujin; Kim, Junghoon; Son, Hyeryon; Choi, Youngjin

    2017-07-01

    The paper proposes a novel apparatus to measure the dynamic elasticity of human limb in order to help the design and fabrication of the personalized prosthetic socket. To take measurements of the dynamic elasticity, the desired force generated as an exponential chirp signal in which the frequency increases and amplitude is maintained according to time progress is applied to human limb and then the skin deformation is recorded, ultimately, to obtain the frequency response of its elasticity. It is referred to as a Dynamic Elasticity Measurement Apparatus (DEMA) in the paper. It has three core components such as linear motor to provide the desired force, loadcell to implement the force feedback control, and potentiometer to record the skin deformation. After measuring the force/deformation and calculating the dynamic elasticity of the limb, it is visualized as 3D color map model of the limb so that the entire dynamic elasticity can be shown at a glance according to the locations and frequencies. For the visualization, the dynamic elasticities measured at specific locations and frequencies are embodied using the color map into 3D limb model acquired by using 3D scanner. To demonstrate the effectiveness, the visualized dynamic elasticities are suggested as outcome of the proposed system, although we do not have any opportunity to apply the proposed system to the amputees. Ultimately, it is expected that the proposed system can be utilized to design and fabricate the personalized prosthetic socket in order for releasing the wearing pain caused by the conventional prosthetic socket.

  7. 38 CFR 17.122 - Payment or reimbursement of the expenses of repairs to prosthetic appliances and similar devices...

    Science.gov (United States)

    2010-07-01

    ... of the expenses of repairs to prosthetic appliances and similar devices furnished without prior... Payment or reimbursement of the expenses of repairs to prosthetic appliances and similar devices furnished without prior authorization. The expenses of repairs to prosthetic appliances, or similar appliances...

  8. The use of titanium for condenser tube bundles

    International Nuclear Information System (INIS)

    Dobrovitch, N.

    2002-01-01

    In a power plant, the condenser is a strategic heat exchanger with regards to the efficiency of the steam turbine and its reliability guarantees the performance and continuous operation of the plant. Until the early 1980's, copper alloys were routinely used in condenser tubes, thanks to their high heat transfer rates. Yet numerous problems arose from the use of this material, such as stress cracking corrosion, ammoniacal corrosion, fouling, erosion, dezincification, abrasion, erosion-corrosion,... and lately the problem of inadequateness of copper with nuclear steam generators (in nuclear power plant the abrasion problem of the copper alloy tubes created a deposit problem in the steam generator conducting to the replacement of all the condensers). The trend was then to consider new tube materials, such stainless steel and titanium, firstly for particular operating conditions and now for most of the projects, with several objectives, such as: 1) improve the reliability (titanium in particular can bring major improvements such as higher water velocities promoting better heat coefficients, excellent resistance to abrasion, erosion and corrosion thereby improving resistance to fouling; 2) find more cost-effective solutions. The first investment is higher but money is saved on maintenance costs and on time reliability of the material. Titanium tube manufacturing has greatly evolved for the last 20 years. Tubes are mostly welded tubes from ASTM SB 338 grade 1 made on a continuous manufacturing line. All manufacturing operations (welding, annealing, non-destructive testing) are fully automated to produce high quality tubes in large quantities. The most common way to attach tubes to a tubesheet is to roller expand them. (A.C.)

  9. Utilization of penile prosthesis and male incontinence prosthetics in Saudi Arabia.

    Science.gov (United States)

    Alwaal, Amjad; Al-Sayyad, Ahmad J

    2017-01-01

    Erectile dysfunction is a prevalent disease affecting over 50% of men between the ages of 40 and 70 years. Penile prosthesis represents the end of the line treatment when other less invasive therapies fail or are contraindicated. Male stress urinary incontinence can significantly diminish quality of life and lead to embarrassment and social withdrawal. Surgical therapies, such as male urethral slings and artificial urinary sphincters (AUS), are considered effective and safe treatments for male stress incontinence. No data exist on the utilization of penile prosthesis or male incontinence surgical treatment in Saudi Arabia. Generally, urological prosthetic surgery is performed either in private hospitals or in government hospitals. Our aim was to assess the trend of penile prosthesis and male incontinence device utilization in Saudi Arabia. We utilized sales' data of penile prosthetics, male slings, and AUS from the only two companies selling these devices in Saudi Arabia (AMS ® and Coloplast ® ), from January 2013 to December 2016. There were 2599 penile prosthesis implantation procedures done in the study period, with 67% of them performed in private institutions. There was a progressively increased use of penile prosthetics which nearly doubled from 2013 to 2016. The main type of prosthesis utilized was the semirigid type 70% versus 11% of the 2-piece inflatable and 17% of the 3-piece inflatable device. Only 10 slings and 31 AUS were inserted during the same study period. There is an increased utilization of penile prosthetics in Saudi Arabia. The private sector performs the majority of penile prosthesis procedures, and most of them are of the semirigid type. The governmental sector is more likely to perform inflatable penile prosthesis and male incontinence device procedures. Male incontinence prosthetics' use is very limited in Saudi Arabia.

  10. Acinetobacter Prosthetic Joint Infection Treated with Debridement and High-Dose Tigecycline.

    Science.gov (United States)

    Vila, Andrea; Pagella, Hugo; Amadio, Claudio; Leiva, Alejandro

    2016-12-01

    Prosthesis retention is not recommended for multidrug-resistant Acinetobacter prosthetic joint infection due to its high failure rate. Nevertheless, replacing the prosthesis implies high morbidity and prolonged hospitalization. Although tigecycline is not approved for the treatment of prosthetic joint infection due to multidrug resistant Acinetobacter baumannii, its appropriate use may preclude prosthesis exchange. Since the area under the curve divided by the minimum inhibitory concentration is the best pharmacodynamic predictor of its efficacy, we used tigecycline at high dose, in order to optimize its efficacy and achieve implant retention in 3 patients who refused prosthesis exchange. All patients with prosthetic joint infections treated at our Institution are prospectively registered in a database. Three patients with early prosthetic joint infection of total hip arthroplasty due to multidrug resistant A. baumannii were treated with debridement, antibiotics and implant retention, using a high maintenance dose of tigecycline (100 mg every 12 hours). The cases were retrospectively reviewed. All patients signed informed consent for receiving off-label use of tigecycline. Tigecycline was well tolerated, allowing its administration at high maintenance dose for a median of 40 days (range 30-60). Two patients were then switched to minocycline at standard doses for a median of 3.3 months in order to complete treatment. Currently, none of the patients showed relapse. Increasing the dose of tigecycline could be considered as a means to better attain pharmacodynamic targets in patients with severe or difficult-to-treat infections. Tigecycline at high maintenance dose might be useful when retention of the implant is attempted for treatment for prosthetic joint infections due to multidrug resistant Acinetobacter. Although this approach might be promising, off-label use of tigecycline should be interpreted cautiously until prospective data are available. Tigecycline is

  11. Evaluation of prosthetic heart valves by transesophageal echocardiography: problems, pitfalls, and timing of echocardiography

    NARCIS (Netherlands)

    van den Brink, Renee B. A.

    2006-01-01

    Transesophageal echocardiography (TEE) is especially suitable for examination of prosthetic valves because of the proximity of the esophagus to the heart and absence of interference with lungs and ribs. This article reviews normal and abnormal morphologic characteristics of prosthetic valves such as

  12. Chemical changes of titanium and titanium dioxide under electron bombardment

    Directory of Open Access Journals (Sweden)

    Romins Brasca

    2007-09-01

    Full Text Available The electron induced effect on the first stages of the titanium (Ti0 oxidation and titanium dioxide (Ti4+ chemical reduction processes has been studied by means of Auger electron spectroscopy. Using factor analysis we found that both processes are characterized by the appearance of an intermediate Ti oxidation state, Ti2O3 (Ti3+.

  13. CRITERIA FOR THE EVALUATION AND ESTIMATION OF IATROGENIC PROSTHETIC FACTORS – SEMIOLOGY AND SYMPTOMATOLOGY

    Directory of Open Access Journals (Sweden)

    G. LUCA

    2013-12-01

    Full Text Available Introduction: The principles lying at the basis of a balanced dental occlusion cannot be analyzed separately, but only if considering the teeth (and, implicitly, dental occlusion as integrated into the masticatory system, which includes the masticatory muscles, the temporo-mandibu‑ lary joint and the maxillary bones. Scope: The scope of the present study was to correlate and establish the interde‑ pendence between the morpholgically-incorrect prosthetic works and the tissular and functional damages suffered by the neighbouring structures, as a result of some incor‑ rectly-made prosthetic works. Also, the study aims at iden‑ tifying the factors and limits responsible for a prolongued maintenance of such irreversible pathological modificati‑ ons within an asymptomatic zone for the patient. Materials and method: The working hypothesis of the present inves‑ tigation started from the analysis of the various objective signs, versus the morphology of the incorrectly performed prosthetic works. The study, initiated as early as 2009, in a private stomatological clinics (DentEstet, Bucuresti, includes a number of 500 patients (250 women and 250 men, selected among the patients having addressed the stomatological office from various reasons (not always related to the prosthetic pathology of the cases here under investigation. Included in the study have been only the patients with fixed prosthetic works associated with one or several of the previously described objective signs, potentially induced by the iatrogeneicity of the prosthetic works. Results: The pathological effects of the iatrogenic works here under analysis, upon both the antagonistic and prosthetic support teeth, may be clinically identified during a minute examination performed prior to produ‑ cing irreversible final effects (abrasions, fractures, dental mobility, etc.. Such noxious effects of the iatrogenic pros‑ thetic works appear as a false masticatory comfort and as a

  14. Osseointegration is improved by coating titanium implants with a nanostructured thin film with titanium carbide and titanium oxides clustered around graphitic carbon

    International Nuclear Information System (INIS)

    Veronesi, Francesca; Giavaresi, Gianluca; Fini, Milena; Longo, Giovanni; Ioannidu, Caterina Alexandra; Scotto d'Abusco, Anna; Superti, Fabiana; Panzini, Gianluca; Misiano, Carlo; Palattella, Alberto; Selleri, Paolo; Di Girolamo, Nicola; Garbarino, Viola; Politi, Laura; Scandurra, Roberto

    2017-01-01

    Titanium implants coated with a 500 nm nanostructured layer, deposited by the Ion Plating Plasma Assisted (IPPA) technology, composed of 60% graphitic carbon, 25% titanium oxides and 15% titanium carbide were implanted into rabbit femurs whilst into the controlateral femurs uncoated titanium implants were inserted as control. At four time points the animals were injected with calcein green, xylenol orange, oxytetracycline and alizarin. After 2, 4 and 8 weeks femurs were removed and processed for histology and static and dynamic histomorphometry for undecalcified bone processing into methylmethacrylate, sectioned, thinned, polished and stained with Toluidine blue and Fast green. The overall bone-implant contacts rate (percentage of bone-implant contacts/weeks) of the TiC coated implant was 1.6 fold than that of the uncoated titanium implant. The histomorphometric analyses confirmed the histological evaluations. More precisely, higher Mineral Apposition Rate (MAR, μm/day) (p < 0.005) and Bone Formation Rate (BFR, μm 2 /μm/day) (p < 0.0005) as well as Bone Implant Contact (Bic) and Bone Ingrowth values (p < 0.0005) were observed for the TiC coated implants compared to uncoated implants. In conclusion the hard nanostructured TiC layer protects the bulk titanium implant against the harsh conditions of biological tissues and in the same time, stimulating adhesion, proliferation and activity of osteoblasts, induces a better bone-implant contacts of the implant compared to the uncoated titanium implant. - Highlights: • Ti implants were coated with a nanostructured film composed of C gr , TiC and TiO x . • The TiC layer stimulates adhesion, proliferation and activity of osteoblasts. • Uncoated and TiC coated titanium implants were implanted in rabbit femurs. • Bone-implant contacts of TiC coated implants were higher than that of uncoated. • Mineral Apposition Rate of TiC coated implants were higher than that of uncoated.

  15. Pre-operative Asymptomatic Bacteriuria: A Risk Factor For Prosthetic Joint Infection?

    Science.gov (United States)

    Weale, R; El-Bakri, F; Saeed, Kordo

    2018-04-13

    Infection is a rare complication following implantation of prosthetic material into a joint. The impact of asymptomatic bacteriuria (ASB) before elective operations and the subsequent risk of prosthetic joint infection (PJI) are not well understood. • Assess the prevalence of ASB amongst patients undergoing total arthroplasty of the hip and knee. • Determine the rates of PJI diagnosed within two years of the arthroplasty and if ASB is an independent risk factor for developing PJI. Patients who had total/unicondylar knee or total hip arthroplasty were retrospectively reviewed over a five-year period. Pre-operative urine samples within one year of surgery were analysed and those with ASB identified. Primary outcome was prosthetic joint infection (PJI) within the first postoperative year. 5542 patients were included. 4368 had a pre-operative urine culture recorded. The prevalence of ASB was 140 of 4368 (3.2%). The overall PJI rate was 56 of 5542 (1.01%). Of those with a PJI, 33 had a pre-operative urine sample recorded. The infection rate in the ASB group was 5% (7 of 140), in the no-ASB group it was 0.61% (26 of 4228) and in the group without a urine sample it was 1.96% (23 of 1174) (p value prosthetic joint, suggestive the relationship is unlikely causal. Copyright © 2018. Published by Elsevier Ltd.

  16. Prosthetics & Orthotics Manufacturing Initiative (POMI)

    Science.gov (United States)

    2012-12-21

    suspension system, socket- ankle /knee interface, etc.) associated with a complete prosthetic system. More specific, the purpose of these deliverables was...strap. The waist belt consists of an adjustable belt utilizing polypropylene buckles and a 2‖ elastic suspension strap which descends to the anchor ...Superior View. Step 8: The suspension component consists of a 1’ anchor strap with a buckle and a 5’ – 6’ long shoulder strap with hook and

  17. Titanium fasteners. [for aircraft industry

    Science.gov (United States)

    Phillips, J. L.

    1972-01-01

    Titanium fasteners are used in large quantities throughout the aircraft industry. Most of this usage is in aluminum structure; where titanium structure exists, titanium fasteners are logically used as well. Titanium fasteners offer potential weight savings to the designer at a cost of approximately $30 per pound of weight saved. Proper and least cost usage must take into consideration type of fastener per application, galvanic couples and installation characteristics of protective coatings, cosmetic appearance, paint adhesion, installation forces and methods available and fatigue performance required.

  18. Titanium for salt water service

    International Nuclear Information System (INIS)

    Gadiyar, H.S.; Shibad, P.R.

    1980-01-01

    Titanium has potential as major material of construction in desalination plants, in condensers and heat exchangers, in view of its excellent corrosion resistance to salt water upto at least 120deg C. The advantages of titanium in such applications are brought out. The various specific problems such as pitting, crevice and galvanic corrosion and the preventive methods, for adopting titanium have been discussed. The hydriding problem can be overcome by suitably controlling the operating parameters such as temperature and surface preparation. A case has been made to prove the economic viability of titanium in comparison to Al-brass and Cu-Ni alloy. The future of titanium seems to be very promising in view of the negligible tube failures and outages. (auth.)

  19. [The surface roughness analysis of the titanium casting founding by a new titanium casting investment material].

    Science.gov (United States)

    Liang, Qin-ye; Wu, Xia-yi; Lin, Xue-feng

    2012-04-01

    To investigate the surface roughness property of the titanium castings cast in a new investment for titanium casting. Six wax patterns (20 mm × 20 mm × 0.5 mm) were invested using two investments: three in a new titanium investment material and three in the control material (Rematitan Plus). Six titanium specimens were obtained by conventional casting. After casting, surface roughness of the specimens were evaluated with a surface profilometer. The surface roughness of the specimens cast in new titanium investment material was (1.72 ± 0.08) µm, which was much smaller than that from Rematitan Plus [(1.91 ± 0.15) µm, P cast using these two investment materials are both smooth enough to fulfill the demand of the titanium precision-casting for prosthodontic clinical use.

  20. Single-stage revision for fungal peri-prosthetic joint infection: a single-centre experience.

    Science.gov (United States)

    Klatte, T O; Kendoff, D; Kamath, A F; Jonen, V; Rueger, J M; Frommelt, L; Gebauer, M; Gehrke, T

    2014-04-01

    Fungal peri-prosthetic infections of the knee and hip are rare but likely to result in devastating complications. In this study we evaluated the results of their management using a single-stage exchange technique. Between 2001 and 2011, 14 patients (ten hips, four knees) were treated for a peri-prosthetic fungal infection. One patient was excluded because revision surgery was not possible owing to a large acetabular defect. One patient developed a further infection two months post-operatively and was excluded from the analysis. Two patients died of unrelated causes. After a mean of seven years (3 to 11) a total of ten patients were available for follow-up. One patient, undergoing revision replacement of the hip, had a post-operative dislocation. Another patient, undergoing revision replacement of the knee, developed a wound infection and required revision 29 months post-operatively following a peri-prosthetic femoral fracture. The mean Harris hip score increased to 74 points (63 to 84; p prosthetic infection is feasible, with an acceptable rate of a satisfactory outcome.

  1. Aerogel Use as a Skin Protective Liner In Space Suits and Prosthetic Limbs Project

    Science.gov (United States)

    Roberson, Luke Bennett

    2014-01-01

    Existing materials for prosthetic liners tend to be thick and airtight, causing perspiration to accumulate inside the liner and potentially causing infection and injury. The purpose of this project was to examine the suitability of aerogel for prosthetic liner applications for use in space suits and orthopedics. Three tests were performed on several types of aerogel to assess the properties of each material, and our initial findings demonstrated that these materrials would be excellent candidates for liner applications for prosthetics and space suits. The project is currently on hold until additional funding is obtained for application testing at the VH Hospitals in Tampa

  2. EEG Mind Controlled Smart Prosthetic Arm – A Comprehensive Study

    Directory of Open Access Journals (Sweden)

    Taha Beyrouthy

    2017-06-01

    Full Text Available Recently, the field of prosthetics has seen many accomplishments especially with the integration of technological advancements. In this paper, different arm types (robotic, surgical, bionic, prosthetic and static are analyzed in terms of resistance, usage, flexibility, cost and potential. Most of these techniques have some problems; they are extremely expensive, hard to install and maintain and may require surgery. Therefore, our work introduces the initial design of an EEG mind controlled smart prosthetic arm. The arm is controlled by the brain commands, obtained from an electroencephalography (EEG headset, and equipped with a network of smart sensors and actuators that give the patient intelligent feedback about the surrounding environment and the object in contact. This network provides the arm with normal hand functionality, smart reflexes and smooth movements. Various types of sensors are used including temperature, pressure, ultrasonic proximity sensors, accelerometers, potentiometers, strain gauges and gyroscopes. The arm is completely 3D printed built from various lightweight and high strength materials that can handle high impacts and fragile elements as well. Our project requires the use of nine servomotors installed at different places in the arm. Therefore, the static and dynamic modes of servomotors are analyzed. The total cost of the project is estimated to be relatively cheap compared to other previously built arms. Many scenarios are analyzed corresponding to the actions that the prosthetic arm can perform, and an algorithm is created to match these scenarios. Experimental results show that the proposed EEG Mind-controlled Arm is a promising alternative for current solutions that require invasive and expensive surgical procedures.

  3. Successful Thrombolysis of Aortic Prosthetic Valve Thrombosis ...

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    patients with valvular heart disease). Endorsed by the Society of Cardiovascular. Anesthesiologists, Society for Cardiovascular. Angiography and Interventions, and Society of. Thoracic Surgeons. J Am Coll Cardiol. 2008;52(13):e1-142. 5. Elkayam U, Bitar F. Valvular heart disease and pregnancy. Part II: prosthetic valves.

  4. Consumer satisfaction in prosthetics and orthotics facilities

    NARCIS (Netherlands)

    Geertzen, J.H.B.; Gankema, H.G.J.; Groothoff, J.W.; Dijkstra, P.U.

    The aim of this study was to assess consumer/patient satisfaction with the services of the prosthetics and orthotics (P&O) facilities in the north of the Netherlands, using a modified SERVQUAL questionnaire. In this questionnaire, consumer interests and experiences are assessed on a 5-point Likert

  5. Prosthetic valve obstruction: Redo surgery or fibrinolysis?

    Directory of Open Access Journals (Sweden)

    Avinash Inamdar

    2017-01-01

    Full Text Available Objective: The aim of this study was to compare the efficacy and safety of surgery versus fibrinolytic therapy in patients with prosthetic valve obstruction. Materials and Methods: We compared 15 patients of prosthetic valve thrombosis treated by surgical line of management and another 15 patients treated by thrombolysis. All patients were initially assessed by clinical evaluation and diagnosis confirmed by transthoracic and transesophageal two-dimensional echocardiography. Depending on hemodynamic stability, pannus, or thrombus on transesophageal echocardiography, the patients were assigned surgical or medical line of management. Results: Patients mortality rate was 40% in fibrinolytic group and 13.33% in surgical group. Recurrence was 40% in fibrinolytic group while there was no recurrence till date in surgery group. Complications were more in fibrinolytic group as opposed to surgery group patient. Conclusion: From our experience, we conclude that redo surgery is effective and definitive treatment, especially in patients with stable hemodynamic conditions.

  6. Self-cleaning skin-like prosthetic polymer surfaces

    Science.gov (United States)

    Simpson, John T [Clinton, TN; Ivanov, Ilia N [Knoxville, TN; Shibata, Jason [Manhattan Beach, CA

    2012-03-27

    An external covering and method of making an external covering for hiding the internal endoskeleton of a mechanical (e.g., prosthetic) device that exhibits skin-like qualities is provided. The external covering generally comprises an internal bulk layer in contact with the endoskeleton of the prosthetic device and an external skin layer disposed about the internal bulk layer. The external skin layer is comprised of a polymer composite with carbon nanotubes embedded therein. The outer surface of the skin layer has multiple cone-shaped projections that provide the external skin layer with superhydrophobicity. The carbon nanotubes are preferably vertically aligned between the inner surface and outer surface of the external skin layer in order to provide the skin layer with the ability to transmit heat. Superhydrophobic powders may optionally be used as part of the polymer composite or applied as a coating to the surface of the skin layer to enhance superhydrophobicity.

  7. Is the Prosthetic Homologue Necessary for Embodiment?

    Science.gov (United States)

    Dornfeld, Chelsea; Swanston, Michelle; Cassella, Joseph; Beasley, Casey; Green, Jacob; Moshayev, Yonatan; Wininger, Michael

    2016-01-01

    Embodiment is the process by which patients with limb loss come to accept their peripheral device as a natural extension of self. However, there is little guidance as to how exacting the prosthesis must be in order for embodiment to take place: is it necessary for the prosthetic hand to look just like the absent hand? Here, we describe a protocol for testing whether an individual would select a hand that looks like their own from among a selection of five hands, and whether the hand selection (regardless of homology) is consistent across multiple exposures to the same (but reordered) set of candidate hands. Pilot results using healthy volunteers reveals that hand selection is only modestly consistent, and that selection of the prosthetic homologue is atypical (61 of 192 total exposures). Our protocol can be executed in minutes, and makes use of readily available equipment and softwares. We present both a face-to-face and a virtual protocol, for maximum flexibility of implementation.

  8. An evaluation of prosthetic status and treatment needs among institutionalized elderly individuals of Delhi, India

    OpenAIRE

    Nisha Yadav; Roma Yadav; Meetika Pahuja; Sanchit Pardhan; Sahiba Miglani; Tamanna Malik

    2017-01-01

    Context: Oral health is essential for elderly person's general health and well-being. The most common oral problem in elderly is tooth loss which results due to periodontal diseases and caries. Prosthetic status is very important as it is related to dietary intake and maintaining nutritional status. Hence, to promote the oral health of the elderly, we need to know their prosthetic status and need. Aims: The aim of this study is to find the prosthetic status and need of 65–74 years old elderly...

  9. Influence of Diamondlike Carbon Coating of Screws on Axial Tightening Force and Stress Distribution on Overdenture Bar Frameworks with Different Fit Levels and Materials.

    Science.gov (United States)

    dos Santos, Mateus Bertolini Fernandes; Bacchi, Atais; Consani, Rafael Leonardo Xediek; Correr-Sobrinho, Lourenço

    2015-01-01

    The aim of this study was to evaluate the axial tightening force applied by conventional and diamondlike carbon (DLC)-coated screws and to verify, through three-dimensional finite element analysis (FEA), the stress distribution caused by different framework materials and prosthetic screws in overdenture frameworks with different misfit levels. The axial tightening force applied by the screw was evaluated by means of a titanium matrix connected to a load cell. Conventional titanium or DLC-coated screws were tightened with a digital torque wrench, and the load values were recorded. The values were applied in an FEA to a bar-clip attachment system connected to two 4.0 × 11-mm external-hexagon titanium implants placed in an anterior edentulous arch. DLC-coated and conventional screws were modeled with their respective axial forces obtained on the experimental evaluation for three bar framework materials (titanium, nickel-chromium, and cobalt-chromium) and three levels of misfit (100, 150, and 200 μm). Von Mises stresses for prosthetic components and maximum principal stress and microstrains (maximum principal strains) for bone tissue were measured. The mean force applied by the conventional screw was 25.55 N (± 1.78); the prosthetic screw coated with a DLC layer applied a mean force of 31.44 N (± 2.11), a statistically significant difference. In the FEA, the DLC screw led to higher stresses on the framework; however, the prosthetic screw suffered lower stress. No influence of screw type was seen in the bone tissue. Titanium frameworks reduced the stress transmitted to the bone tissue and the bar framework but had no influence on the screws. Higher misfit values resulted in an increased stress/strain in bone tissue and bar framework, which was not the case for retention screws.

  10. Numerical assessment of bone remodeling around conventionally and early loaded titanium and titanium-zirconium alloy dental implants.

    Science.gov (United States)

    Akça, Kıvanç; Eser, Atılım; Çavuşoğlu, Yeliz; Sağırkaya, Elçin; Çehreli, Murat Cavit

    2015-05-01

    The aim of this study was to investigate conventionally and early loaded titanium and titanium-zirconium alloy implants by three-dimensional finite element stress analysis. Three-dimensional model of a dental implant was created and a thread area was established as a region of interest in trabecular bone to study a localized part of the global model with a refined mesh. The peri-implant tissues around conventionally loaded (model 1) and early loaded (model 2) implants were implemented and were used to explore principal stresses, displacement values, and equivalent strains in the peri-implant region of titanium and titanium-zirconium implants under static load of 300 N with or without 30° inclination applied on top of the abutment surface. Under axial loading, principal stresses in both models were comparable for both implants and models. Under oblique loading, principal stresses around titanium-zirconium implants were slightly higher in both models. Comparable stress magnitudes were observed in both models. The displacement values and equivalent strain amplitudes around both implants and models were similar. Peri-implant bone around titanium and titanium-zirconium implants experiences similar stress magnitudes coupled with intraosseous implant displacement values under conventional loading and early loading simulations. Titanium-zirconium implants have biomechanical outcome comparable to conventional titanium implants under conventional loading and early loading.

  11. Smart Prosthetic Hand Technology - Phase 2

    Science.gov (United States)

    2011-05-01

    functional magnetic resonance imaging (f- MRI ) was used to analyze the reciprocal adaptation between the human brain and the prosthetic hand by the...Schmidt PC. Influence of compacted hydrophobic and hydrophilic colloidal silicon dioxide on tableting properties of pharmaceutical excipients. Drug Dev...nanoparticles, and manganese nanoparticles) in magnetic resonance imaging ( MRI ) in the detection and staging of cancer [2]. 2.1 Iron Oxide

  12. Immediate effects of a new microprocessor-controlled prosthetic knee joint: a comparative biomechanical evaluation.

    Science.gov (United States)

    Bellmann, Malte; Schmalz, Thomas; Ludwigs, Eva; Blumentritt, Siegmar

    2012-03-01

    To investigate the immediate biomechanical effects after transition to a new microprocessor-controlled prosthetic knee joint. Intervention cross-over study with repeated measures. Only prosthetic knee joints were changed. Motion analysis laboratory. Men (N=11; mean age ± SD, 36.7±10.2y; Medicare functional classification level, 3-4) with unilateral transfemoral amputation. Two microprocessor-controlled prosthetic knee joints: C-Leg and a new prosthetic knee joint, Genium. Static prosthetic alignment, time-distance parameters, kinematic and kinetic parameters, and center of pressure. After a half-day training and an additional half-day accommodation, improved biomechanical outcomes were demonstrated by the Genium: lower ground reaction forces at weight acceptance during level walking at various velocities, increased swing phase flexion angles during walking on a ramp, and level walking with small steps. Maximum knee flexion angle during swing phase at various velocities was nearly equal for Genium. Step-over-step stair ascent with the Genium knee was more physiologic as demonstrated by a more equal load distribution between the prosthetic and contralateral sides and a more natural gait pattern. When descending stairs and ramps, knee flexion moments with the Genium tended to increase. During quiet stance on a decline, subjects using Genium accepted higher loading of the prosthetic side knee joint, thus reducing same side hip joint loading as well as postural sway. In comparision to the C-Leg, the Genium demonstrated immediate biomechanical advantages during various daily ambulatory activities, which may lead to an increase in range and diversity of activity of people with above-knee amputations. Results showed that use of the Genium facilitated more natural gait biomechanics and load distribution throughout the affected and sound musculoskeletal structure. This was observed during quiet stance on a decline, walking on level ground, and walking up and down ramps and

  13. Prosthetic joint infection caused by Pasteurella multocida: a case series and review of literature.

    Science.gov (United States)

    Honnorat, Estelle; Seng, Piseth; Savini, Hélène; Pinelli, Pierre-Olivier; Simon, Fabrice; Stein, Andreas

    2016-08-20

    Pasteurella multocida is a well-recognized zoonotic agent following dog or cat bites or scratches. Nevertheless, prosthetic joint infection caused by P. multocida are rarely reported. We report here a series of six cases of prosthetic joint infection caused by P. multocida managed at a referral centre for the treatment of bone and joint infection in southern France. We also reviewed the 26 cases reported in literature. The mean age of our cases was 74 years [±8.2, range 63-85]. In majority of our cases (5 cases) were associated with knee prostheses and one case with a hip prosthesis. Most of cases occurred after cat or dog scratches or licks or contact. Diagnoses of prosthetic joint infection caused by P. multocida were made by positive cultures of surgical biopsies or needle aspiration. Mean time delay between prosthetic joint implantation and infection onset was 7.6 years (±5.12 years, range 2-17). Local inflammation, which occurred in all six cases, was the most frequent clinical symptom, followed by pain in five cases, fever and swollen joints in four cases, and a fistula with purulent discharge inside the wound in two cases. The mean time of antibiotic therapy was 8 months. Surgical treatment with prosthesis removal was performed in three cases. Six of our cases were in remission without apparent relapse at 3 years after end of treatment. Prosthetic joint infections caused by P. multocida usually occur after animal scratches or bites, but can occasionally occur after a short animal lick. These infections are usually resulting from a contiguous infection and localized in the knee. An early antibiotic therapy after surgical debridement could avoid prosthetic withdrawal, notably in elderly patients. Patients with prosthetic joints should be warned that animals are potential sources of serious infection and urgent medical advice should be sought if they are bitten or scratched.

  14. Systematic variation of prosthetic foot spring affects center-of-mass mechanics and metabolic cost during walking.

    Science.gov (United States)

    Zelik, Karl E; Collins, Steven H; Adamczyk, Peter G; Segal, Ava D; Klute, Glenn K; Morgenroth, David C; Hahn, Michael E; Orendurff, Michael S; Czerniecki, Joseph M; Kuo, Arthur D

    2011-08-01

    Lower-limb amputees expend more energy to walk than non-amputees and have an elevated risk of secondary disabilities. Insufficient push-off by the prosthetic foot may be a contributing factor. We aimed to systematically study the effect of prosthetic foot mechanics on gait, to gain insight into fundamental prosthetic design principles. We varied a single parameter in isolation, the energy-storing spring in a prototype prosthetic foot, the controlled energy storage and return (CESR) foot, and observed the effect on gait. Subjects walked on the CESR foot with three different springs. We performed parallel studies on amputees and on non-amputees wearing prosthetic simulators. In both groups, spring characteristics similarly affected ankle and body center-of-mass (COM) mechanics and metabolic cost. Softer springs led to greater energy storage, energy return, and prosthetic limb COM push-off work. But metabolic energy expenditure was lowest with a spring of intermediate stiffness, suggesting biomechanical disadvantages to the softest spring despite its greater push-off. Disadvantages of the softest spring may include excessive heel displacements and COM collision losses. We also observed some differences in joint kinetics between amputees and non-amputees walking on the prototype foot. During prosthetic push-off, amputees exhibited reduced energy transfer from the prosthesis to the COM along with increased hip work, perhaps due to greater energy dissipation at the knee. Nevertheless, the results indicate that spring compliance can contribute to push-off, but with biomechanical trade-offs that limit the degree to which greater push-off might improve walking economy. © 2011 IEEE

  15. The Prosthetic Experience Between Body and Technology

    DEFF Research Database (Denmark)

    Søndergaard, Morten

    2018-01-01

    In this paper, I argue that a prosthetic aesthetic instigated by experimental art practices operate with and within a ‘second nature’ – in-between science and art. Drawing on theories from Dewey and Edelman and examples from Da Vinci, Brancusi, Man Ray, Dali and Stelarc, I am calling...

  16. Aortic allografts in treatment of aortic valve and ascending aorta prosthetic endocarditis

    Directory of Open Access Journals (Sweden)

    S.V. Spiridonov

    2017-03-01

    Full Text Available The aim – to assess short- and long-term results of aortic root replacement using aortic allografts in patients with prosthetic endocarditis. Materials and methods. Since February 2009 until June 2016 aortic valve and ascending aorta replacement using aortic allografts was performed in 26 patients with prosthetic endocarditis. In 50 % of cases at initial operation aortic valve replacement was performed, in another 50 % of cases – aortic valve and ascending aorta replacement. Echocardiography was performed 10 days, 3, 6 and 12 months, 2, 3 and 5 years after surgery. Analysis of long-term results included all cases of deaths, prosthesis-related complications and recurrence of endocarditis. Results. 30-day mortality was 23.1 %. Extracorporeal membranous oxygenation (ECMO was used only in 5 patients (19.2 %. Four patients were weaned from ECMO. We did not observe any allograft-related complications. During follow-up period there were no cases of reoperation due to structural allograft failure. Relapse of infection occurred in 1 patient (3.8 % four years after the operation and led to lethal outcome. Conclusion. Reoperations using allografts are an effective surgical treatment of prosthetic endocarditis. In majority of cases prosthetic endocarditis was caused by gram-positive cocci (Staphylococcus. In 84.6 % of cases it was associated with destruction of paravalvular structures and abscesses formation. Heart failure was a causative factor of different complications in these patients, which required ECMO in 19.2 % of patients. In 80 % of cases patients were weaned from ECMO. Allografts using for the treatment of prosthetic endocarditis is associated with high resistance to infection and with a significant rate of freedom from recurrence of endocarditis within 3 years after surgery.

  17. Selected applications for current polymers in prosthetic dentistry - state of the art.

    Science.gov (United States)

    Kawala, Maciej; Smardz, Joanna; Adamczyk, Lukasz; Grychowska, Natalia; Wieckiewicz, Mieszko

    2018-05-10

    Polymers are widely applied in medicine, including dentistry, i.e. in prosthodontics. The following paper is aimed at demonstrating the applications of selected modern polymers in prosthetic dentistry based on the reported literature. The study was conducted using the PubMed, SCOPUS and CINAHL databases in relation to documents published during 1999-2017. The following keywords were used: polymers with: prosthetic dentistry, impression materials, denture base materials, bite registration materials, denture soft liners, occlusal splint materials and 3D printing. Original papers and reviews which were significant from the modern clinical viewpoint and practical validity in relation to the possibility of using polymeric materials in prosthetic dentistry, were presented. Denture base materials were most commonly modified polymers. Modifications mainly concerned antimicrobial properties and reinforcement of the material structure by introducing additional fibers. Antimicrobial modifications were also common in case of relining materials. Polymeric materials have widely been used in prosthetic dentistry. Modifications of their composition allow achieving new, beneficial properties that affect quality of patients' life. Progress in science allows for a more methodologically-advanced research on the synthesis of new polymeric materials and incorporation of new substances into already known polymeric materials, that will require systematization and appropriate classification. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  18. Anodic growth of titanium dioxide nanostructures

    DEFF Research Database (Denmark)

    2010-01-01

    Disclosed is a method of producing nanostructures of titanium dioxide (TiO 2 ) by anodisation of titanium (Ti) in an electrochemical cell, comprising the steps of: immersing a non-conducting substrate coated with a layer of titanium, defined as the anode, in an electrolyte solution...... an electrical contact to the layer of titanium on the anode, where the electrical contact is made in the electrolyte solution...

  19. Characterization of microbes in prosthetic joint specimens by culture-independent molecular methods

    DEFF Research Database (Denmark)

    Xu, Yijuan; Rudkjøbing, Vibeke Børsholt; Simonsen, Ole

    Prosthetic joint infection (PJI) is one of the most challenging complications of joint alloplasty. Formation of biofilm is a prominent feature of PJIs and constitutes a challenge to current sampling procedures and culture practices to obtain a reliable diagnosis. The aim of the study was to inves......Prosthetic joint infection (PJI) is one of the most challenging complications of joint alloplasty. Formation of biofilm is a prominent feature of PJIs and constitutes a challenge to current sampling procedures and culture practices to obtain a reliable diagnosis. The aim of the study...... was to investigate the microbial diversity in surgical samples (eg. synovial fluid, periprosthetic tissue, removed prosthesis) from 22 prosthetic patients using a range of culture-independent molecular methods including broad range 16S rRNA gene PCR, cloning, phylogeny, quantitative PCR (qPCR), and fluorescence...

  20. Novel implant for peri-prosthetic proximal tibia fractures.

    Science.gov (United States)

    Tran, Ton; Chen, Bernard K; Wu, Xinhua; Pun, Chung Lun

    2018-03-01

    Repair of peri-prosthetic proximal tibia fractures is very challenging in patients with a total knee replacement or arthroplasty. The tibial component of the knee implant severely restricts the fixation points of the tibial implant to repair peri-prosthetic fractures. A novel implant has been designed with an extended flange over the anterior of tibial condyle to provide additional points of fixation, overcoming limitations of existing generic locking plates used for proximal tibia fractures. Furthermore, the screws fixed through the extended flange provide additional support to prevent the problem of subsidence of tibial component of knee implant. The design methodology involved extraction of bone data from CT scans into a flexible CAD format, implant design and structural evaluation and optimisation using FEM as well as prototype development and manufacture by selective laser melting 3D printing technology with Ti6Al4 V powder. A prototype tibia implant was developed based on a patient-specific bone structure, which was regenerated from the CT images of patient's tibia. The design is described in detail and being applied to fit up to 80% of patients, for both left and right sides based on the average dimensions and shape of the bone structure from a wide range of CT images. A novel tibial implant has been developed to repair peri-prosthetic proximal tibia fractures which overcomes significant constraints from the tibial component of existing knee implant. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Characterization of a tubular flow chamber for studying platelet interaction with biologic and prosthetic materials: deposition of indium 111-labeled platelets on collagen, subendothelium, and expanded polytetrafluoroethylene

    International Nuclear Information System (INIS)

    Badimon, L.; Turitto, V.; Rosemark, J.A.; Badimon, J.J.; Fuster, V.

    1987-01-01

    A plastic (Plexiglas) chamber for evaluating platelet deposition under controlled hemodynamic conditions has been developed. The perfusion chamber has been designed to retain the cylindrical shape typical of the vasculature, to be flexible enough to accept a variety of biologic and prosthetic materials, and to simulate a broad range of physiologic flow conditions in either an ex vivo or in vitro perfusion system. Three type of surfaces were exposed to blood flowing directly from the carotid artery of a heparinized pig through the perfusion chamber: de-endothelialized pig aorta, collagen strips from rabbit Achilles tendon, and an expanded polytetrafluoroethylene material (Gore-Tex). Platelets, previously radiolabeled with indium 111 and injected into the animal, were quantified on the material surface, and the total number of deposited platelets determined for a range of blood flow rates (5 to 40 ml/min) and exposure times (0.5 to 20 minutes). The deposition rates were correlated with theory for describing the mass transport of platelets to the test surface. At the wall shear rates investigated (105 to 850 sec-1), the deposition of platelets on subendothelium was strongly dependent on the local flow conditions. Values of deposition on Gore-Tex obtained at similar flow conditions (105 to 425 sec-1) were reduced compared with that observed on subendothelium and showed a markedly weaker dependence on the shear rate. In contrast, deposition of platelets on collagen was more than an order of magnitude greater than on subendothelium and showed a dependence on flow only at the lowest flow rate studied (10 ml/min). The results indicate that collagen is much more reactive than subendothelium and Gore-Tex with respect to the growth and stability of platelet aggregates and moreover suggest that flow mechanisms for depositing platelets on various surface may be substantially different

  2. Characterization of a tubular flow chamber for studying platelet interaction with biologic and prosthetic materials: deposition of indium 111-labeled platelets on collagen, subendothelium, and expanded polytetrafluoroethylene

    Energy Technology Data Exchange (ETDEWEB)

    Badimon, L.; Turitto, V.; Rosemark, J.A.; Badimon, J.J.; Fuster, V.

    1987-12-01

    A plastic (Plexiglas) chamber for evaluating platelet deposition under controlled hemodynamic conditions has been developed. The perfusion chamber has been designed to retain the cylindrical shape typical of the vasculature, to be flexible enough to accept a variety of biologic and prosthetic materials, and to simulate a broad range of physiologic flow conditions in either an ex vivo or in vitro perfusion system. Three type of surfaces were exposed to blood flowing directly from the carotid artery of a heparinized pig through the perfusion chamber: de-endothelialized pig aorta, collagen strips from rabbit Achilles tendon, and an expanded polytetrafluoroethylene material (Gore-Tex). Platelets, previously radiolabeled with indium 111 and injected into the animal, were quantified on the material surface, and the total number of deposited platelets determined for a range of blood flow rates (5 to 40 ml/min) and exposure times (0.5 to 20 minutes). The deposition rates were correlated with theory for describing the mass transport of platelets to the test surface. At the wall shear rates investigated (105 to 850 sec-1), the deposition of platelets on subendothelium was strongly dependent on the local flow conditions. Values of deposition on Gore-Tex obtained at similar flow conditions (105 to 425 sec-1) were reduced compared with that observed on subendothelium and showed a markedly weaker dependence on the shear rate. In contrast, deposition of platelets on collagen was more than an order of magnitude greater than on subendothelium and showed a dependence on flow only at the lowest flow rate studied (10 ml/min). The results indicate that collagen is much more reactive than subendothelium and Gore-Tex with respect to the growth and stability of platelet aggregates and moreover suggest that flow mechanisms for depositing platelets on various surface may be substantially different.

  3. The influence of environmental and personal factors on participation of lower-limb prosthetic users in low-income countries: prosthetists' perspectives.

    Science.gov (United States)

    Kam, Season; Kent, Mallory; Khodaverdian, Alin; Daiter, Liane; Njelesani, Janet; Cameron, Debra; Andrysek, Jan

    2015-05-01

    To examine the environmental and personal factors in low-income countries (LICs) that influence prosthetic rehabilitation of adults with lower-limb (LL) amputations and their ability to participate in daily activities. In this qualitative descriptive study, 11 prosthetists participated in semi-structured interviews by telephone or Skype. Qualitative thematic analysis was guided by the International Classification of Function. Facilitating continuity of care, consideration of physical environments and usage, prosthetic quality including durability and socket fit, and minimizing the visibility of disability, were found to be important factors affecting the provision of prosthetic services in LICs. Environmental and personal factors must be considered when providing prosthetic rehabilitation for adults with LL amputations in LICs in order to optimize participation in activities. Results from this study provide new insights about some of the factors that influence the ability of individuals with LL amputations to rehabilitate to a level where they are able to participate in meaningful activities within their communities. There are unique environmental and personal components that can influence activity and participation of lower-limb (LL) prosthetic users in low-income countries (LICs). These components are often overlooked in the design of prosthetic devices and provision of prosthetic services. Continuity of care, condition of the post-surgical residuum, outdoor environments of common occupations, aesthetics and durability of prostheses, and user comfort should all be considered when providing prosthetic rehabilitation to adults with LL amputations in LICs to promote activity and participation. Results of our study can inform the practice of prosthetists in LICs by highlighting their contributions in enabling participation for LL prosthetic users. Our results can also inform the design of durable and comfortable prostheses and the provision of more appropriate

  4. Nitinol for Prosthetic and Orthotic Applications

    Science.gov (United States)

    Henderson, Emma; Buis, Arjan

    2011-07-01

    As global populations age, conditions such as stroke and diabetes require individuals to use rehabilitation technology for many years to come due to chronic musculoskeletal, sensory, and other physical impairments. One in four males currently aged 45 will experience a stroke within 40 years and will often require access to prolonged rehabilitation. In addition, worldwide, one individual loses a limb every 30 s due to the complications of diabetes. As a result, innovative ideas are required to devise more effective prosthetic and orthotic devices to enhance quality of life. While Nitinol has already found much favor within the biomedical industry, one area, which has not yet exploited its unique properties, is in the field of physical rehabilitation, ranging from prosthetic and orthotic devices to assistive technology such as wheelchairs. Improved intervention capabilities based on materials such as Nitinol have the potential to vastly improve patients' quality of life and in the case of orthoses, may even reduce the severity of the condition over time. It is hoped that this study will spark discussion and interest for the materials community in a field which has yet to be fully exploited.

  5. An optimized content-aware image retargeting method: toward expanding the perceived visual field of the high-density retinal prosthesis recipients

    Science.gov (United States)

    Li, Heng; Zeng, Yajie; Lu, Zhuofan; Cao, Xiaofei; Su, Xiaofan; Sui, Xiaohong; Wang, Jing; Chai, Xinyu

    2018-04-01

    Objective. Retinal prosthesis devices have shown great value in restoring some sight for individuals with profoundly impaired vision, but the visual acuity and visual field provided by prostheses greatly limit recipients’ visual experience. In this paper, we employ computer vision approaches to seek to expand the perceptible visual field in patients implanted potentially with a high-density retinal prosthesis while maintaining visual acuity as much as possible. Approach. We propose an optimized content-aware image retargeting method, by introducing salient object detection based on color and intensity-difference contrast, aiming to remap important information of a scene into a small visual field and preserve their original scale as much as possible. It may improve prosthetic recipients’ perceived visual field and aid in performing some visual tasks (e.g. object detection and object recognition). To verify our method, psychophysical experiments, detecting object number and recognizing objects, are conducted under simulated prosthetic vision. As control, we use three other image retargeting techniques, including Cropping, Scaling, and seam-assisted shrinkability. Main results. Results show that our method outperforms in preserving more key features and has significantly higher recognition accuracy in comparison with other three image retargeting methods under the condition of small visual field and low-resolution. Significance. The proposed method is beneficial to expand the perceived visual field of prosthesis recipients and improve their object detection and recognition performance. It suggests that our method may provide an effective option for image processing module in future high-density retinal implants.

  6. Osseointegration is improved by coating titanium implants with a nanostructured thin film with titanium carbide and titanium oxides clustered around graphitic carbon

    Energy Technology Data Exchange (ETDEWEB)

    Veronesi, Francesca [Laboratory of Preclinical and Surgical Studies, Rizzoli Orthopedic Institute, Via Di Barbiano 1/10, Bologna 40136 (Italy); Giavaresi, Gianluca; Fini, Milena [Laboratory of Preclinical and Surgical Studies, Rizzoli Orthopedic Institute, Via Di Barbiano 1/10, Bologna 40136 (Italy); Laboratory of Biocompatibility, Innovative Technologies and Advanced Therapies, Department Rizzoli RIT, Via Di Barbiano 1/10, Bologna 40136 (Italy); Longo, Giovanni [CNR Istituto di Struttura della Materia, CNR, Via del Fosso del Cavaliere 100, 00133 Roma (Italy); Ioannidu, Caterina Alexandra; Scotto d' Abusco, Anna [Dept. of Biochemical Sciences, Sapienza University of Roma, Ple A. Moro 5, 00185 Roma (Italy); Superti, Fabiana; Panzini, Gianluca [Dept. of Technologies and Health, Istituto Superiore di Sanità, Viale Regina Elena, 299 Roma (Italy); Misiano, Carlo [Romana Film Sottili, Anzio, Roma (Italy); Palattella, Alberto [Dept. of Clinical Sciences and Translational Medicine, Tor Vergata University, Via Montpellier 1, 00133 Roma (Italy); Selleri, Paolo; Di Girolamo, Nicola [Exotic Animals Clinic, Via S. Giovannini 53, 00137 Roma (Italy); Garbarino, Viola [Dept. of Radiology, S.M. Goretti Hospital, Via G. Reni 2, 04100 Latina (Italy); Politi, Laura [Dept. of Biochemical Sciences, Sapienza University of Roma, Ple A. Moro 5, 00185 Roma (Italy); Scandurra, Roberto, E-mail: roberto.scandurra@uniroma1.it [Dept. of Biochemical Sciences, Sapienza University of Roma, Ple A. Moro 5, 00185 Roma (Italy)

    2017-01-01

    Titanium implants coated with a 500 nm nanostructured layer, deposited by the Ion Plating Plasma Assisted (IPPA) technology, composed of 60% graphitic carbon, 25% titanium oxides and 15% titanium carbide were implanted into rabbit femurs whilst into the controlateral femurs uncoated titanium implants were inserted as control. At four time points the animals were injected with calcein green, xylenol orange, oxytetracycline and alizarin. After 2, 4 and 8 weeks femurs were removed and processed for histology and static and dynamic histomorphometry for undecalcified bone processing into methylmethacrylate, sectioned, thinned, polished and stained with Toluidine blue and Fast green. The overall bone-implant contacts rate (percentage of bone-implant contacts/weeks) of the TiC coated implant was 1.6 fold than that of the uncoated titanium implant. The histomorphometric analyses confirmed the histological evaluations. More precisely, higher Mineral Apposition Rate (MAR, μm/day) (p < 0.005) and Bone Formation Rate (BFR, μm{sup 2}/μm/day) (p < 0.0005) as well as Bone Implant Contact (Bic) and Bone Ingrowth values (p < 0.0005) were observed for the TiC coated implants compared to uncoated implants. In conclusion the hard nanostructured TiC layer protects the bulk titanium implant against the harsh conditions of biological tissues and in the same time, stimulating adhesion, proliferation and activity of osteoblasts, induces a better bone-implant contacts of the implant compared to the uncoated titanium implant. - Highlights: • Ti implants were coated with a nanostructured film composed of C{sub gr}, TiC and TiO{sub x}. • The TiC layer stimulates adhesion, proliferation and activity of osteoblasts. • Uncoated and TiC coated titanium implants were implanted in rabbit femurs. • Bone-implant contacts of TiC coated implants were higher than that of uncoated. • Mineral Apposition Rate of TiC coated implants were higher than that of uncoated.

  7. The vapour phase deposition of boron on titanium by the reaction between gaseous boron trichloride and titanium metal. Final report

    International Nuclear Information System (INIS)

    Cameron, D.J.; Shelton, R.A.J.

    1965-03-01

    The reaction, between boron trichloride vapour and titanium has been investigated in the temperature range 200 - 1350 deg. C. It has been found that an initial reaction leads to the formation of titanium tetrachloride and the deposition of boron on titanium, but that except for reactions between 900 and 1000 deg. C, the system is complicated by the formation of lower titanium chlorides due to secondary reactions between the titanium and titanium tetrachloride

  8. A survey of prosthetic eye wearers to investigate mucoid discharge

    Directory of Open Access Journals (Sweden)

    Pine K

    2012-05-01

    Full Text Available Keith Pine1, Brian Sloan2, Joanna Stewart3, Robert J Jacobs11Department of Optometry and Vision Science, 2Department of Ophthalmology, New Zealand National Eye Centre, 3Section of Epidemiology and Biostatistics, School of Population Health, University of Auckland, Auckland, New ZealandBackground: This study aimed to better understand the causes and treatments of mucoid discharge associated with prosthetic eye wear by reviewing the literature and surveying anophthalmic patients.Methods: An anonymous questionnaire was completed by 429 prosthetic eye wearers who used visual analog scales to self-measure their discharge experience for four discharge characteristics: frequency, color, volume, and viscosity. These characteristics were analyzed with age, ethnicity, years wearing a prosthesis, eye loss cause, removal and cleaning regimes, hand-washing behavior, age of current prosthesis, and professional repolishing regimes as explanatory variables. Eighteen ocularists’ Web sites containing comments on the cause and treatment of discharge were surveyed.Results: Associations were found between discharge frequency and cleaning regimes with more frequent cleaning accompanying more frequent discharge. Color was associated with years of wearing and age, with more years of wearing and older people having less colored discharge. Volume was associated with cleaning regimes with more frequent cleaners having more volume. Viscosity was associated with cleaning regimes and years of wearing with more frequent cleaning and shorter wearing time accompanying more viscous discharge. No associations were found between discharge characteristics and ethnicity, eye loss cause, hand washing, age of current prosthesis, or repolishing regimes. Forty-seven percent of ocularists’ Web sites advised that discharge was caused by surface deposits on the prosthesis, 29% by excessive handling of the prosthesis, and 24% by other causes.Conclusions: A standardized treatment

  9. Fabrication of titanium removable dental prosthesis frameworks with a 2-step investment coating method.

    Science.gov (United States)

    Koike, Mari; Hummel, Susan K; Ball, John D; Okabe, Toru

    2012-06-01

    Although pure titanium is known to have good biocompatibility, a titanium alloy with better strength is needed for fabricating clinically acceptable, partial removable dental prosthesis (RDP) frameworks. The mechanical properties of an experimental Ti-5Al-5Cu alloy cast with a 2-step investment technique were examined for RDP framework applications. Patterns for tests for various properties and denture frameworks for a preliminary trial casting were invested with a 2-step coating method using 2 types of mold materials: a less reactive spinel compound (Al(2)O(3)·MgO) and a less expensive SiO(2)-based material. The yield and tensile strength (n=5), modulus of elasticity (n=5), elongation (n=5), and hardness (n=8) of the cast Ti-5Al-5Cu alloy were determined. The external appearance and internal porosities of the preliminary trial castings of denture frameworks (n=2) were examined with a conventional dental radiographic unit. Cast Ti-6Al-4V alloy and commercially pure titanium (CP Ti) were used as controls. The data for the mechanical properties were statistically analyzed with 1-way ANOVA (α=.05). The yield strength of the cast Ti-5Al-5Cu alloy was 851 MPa and the hardness was 356 HV. These properties were comparable to those of the cast Ti-6Al-4V and were higher than those of CP Ti (PAl-5Cu frameworks was found to have been incompletely cast. The cast biocompatible experimental Ti-5Al-5Cu alloy exhibited high strength when cast with a 2-step coating method. With a dedicated study to determine the effect of sprue design on the quality of castings, biocompatible Ti-5Al-5Cu RDP frameworks for a clinical trial can be produced. Copyright © 2012 The Editorial Council of the Journal of Prosthetic Dentistry. Published by Mosby, Inc. All rights reserved.

  10. Prosthetic management of an ocular defect

    Directory of Open Access Journals (Sweden)

    Siddesh Kumar Chintal

    2010-01-01

    Full Text Available The disfigurement associated with the loss of an eye can cause significant physical and emotional problems. Various treatment modalities are available, one of which is implants. Although implant has a superior outcome, it may not be advisable in all patients due to economic factors. The present article describes the prosthetic management of an ocular defect with a custom-made ocular prosthesis.

  11. LEUKOCYTE AND BACTERIA IMAGING IN PROSTHETIC JOINT INFECTION

    NARCIS (Netherlands)

    Glaudemans, Andor W. J. M.; Galli, Filippo; Pacilio, Marta; Signore, Alberto

    2013-01-01

    There has been a significant increase in the number of joint prosthesis replacements worldwide. Although relatively uncommon, complications can occur with the most serious being an infection. Various radiological and nuclear imaging techniques are available to diagnose prosthetic joint infections

  12. Esthetic, functional, and prosthetic outcomes with implant-retained finger prostheses.

    Science.gov (United States)

    Aydin, Cemal; Nemli, Secil Karakoca; Yilmaz, Handan

    2013-04-01

    Traumatic amputation of fingers results in a serious impairment of hand function and affects the psychological status of the patients. The implant-retained finger prostheses are an alternative treatment. The aim of this case report is to represent the use of osseointegrated implants for retention of finger prostheses in a patient with amputated thumb and index finger. Dental implants were placed in the residual bone of the fingers using two-stage surgery. Custom-made attachments were used to provide retention between implants and silicone prostheses. Prosthetic fingernails were made of composite resin material. After 6 months, implants were clinically successful, and the patient was satisfied with the appearance and the function of the prostheses. The complications of broken prosthetic nail and mild discoloration were observed. Reconstruction of amputated fingers with implant-retained prosthesis is a worthwhile treatment providing esthetic, functional, and psychological benefits, although some complications might be experienced. Clinical relevance Implant-retained finger prostheses are an acceptable treatment modality for patients with amputated fingers. Evaluating implant prognosis, functional results and prosthetic results of the patients are necessary to address the benefits and complications of the treatment.

  13. Nuclear Medicine in Diagnosis of Prosthetic Valve Endocarditis: An Update

    Science.gov (United States)

    Musso, Maria; Petrosillo, Nicola

    2015-01-01

    Over the past decades cardiovascular disease management has been substantially improved by the increasing introduction of medical devices as prosthetic valves. The yearly rate of infective endocarditis (IE) in patient with a prosthetic valve is approximately 3 cases per 1,000 patients. The fatality rate of prosthetic valve endocarditis (PVE) remains stable over the years, in part due to the aging of the population. The diagnostic value of echocardiography in diagnosis is operator-dependent and its sensitivity can decrease in presence of intracardiac devices and valvular prosthesis. The modified Duke criteria are considered the gold standard for diagnosing IE; their sensibility is 80%, but in clinical practice their diagnostic accuracy in PVE is lower, resulting inconclusively in nearly 30% of cases. In the last years, these new imaging modalities have gained an increasing attention because they make it possible to diagnose an IE earlier than the structural alterations occurring. Several studies have been conducted in order to assess the diagnostic accuracy of various nuclear medicine techniques in diagnosis of PVE. We performed a review of the literature to assess the available evidence on the role of nuclear medicine techniques in the diagnosis of PVE. PMID:25695043

  14. The effects of a controlled energy storage and return prototype prosthetic foot on transtibial amputee ambulation.

    Science.gov (United States)

    Segal, Ava D; Zelik, Karl E; Klute, Glenn K; Morgenroth, David C; Hahn, Michael E; Orendurff, Michael S; Adamczyk, Peter G; Collins, Steven H; Kuo, Arthur D; Czerniecki, Joseph M

    2012-08-01

    The lack of functional ankle musculature in lower limb amputees contributes to the reduced prosthetic ankle push-off, compensations at other joints and more energetically costly gait commonly observed in comparison to non-amputees. A variety of energy storing and return prosthetic feet have been developed to address these issues but have not been shown to sufficiently improve amputee biomechanics and energetic cost, perhaps because the timing and magnitude of energy return is not controlled. The goal of this study was to examine how a prototype microprocessor-controlled prosthetic foot designed to store some of the energy during loading and return it during push-off affects amputee gait. Unilateral transtibial amputees wore the Controlled Energy Storage and Return prosthetic foot (CESR), a conventional foot (CONV), and their previously prescribed foot (PRES) in random order. Three-dimensional gait analysis and net oxygen consumption were collected as participants walked at constant speed. The CESR foot demonstrated increased energy storage during early stance, increased prosthetic foot peak push-off power and work, increased prosthetic limb center of mass (COM) push-off work and decreased intact limb COM collision work compared to CONV and PRES. The biological contribution of the positive COM work for CESR was reduced compared to CONV and PRES. However, the net metabolic cost for CESR did not change compared to CONV and increased compared to PRES, which may partially reflect the greater weight, lack of individualized size and stiffness and relatively less familiarity for CESR and CONV. Controlled energy storage and return enhanced prosthetic push-off, but requires further design modifications to improve amputee walking economy. Published by Elsevier B.V.

  15. The influence of staff training and education on prosthetic and orthotic service quality: A scoping review.

    Science.gov (United States)

    Forghany, Saeed; Sadeghi-Demneh, Ebrahim; Trinler, Ursula; Onmanee, Pornsuree; Dillon, Michael P; Baker, Richard

    2018-06-01

    Education and training in prosthetics and orthotics typically comply with International Society for Prosthetics and Orthotics standards based on three categories of prosthetic and orthotic professionals. This scoping study sought to describe the evidence base available to answer the question, How are prosthetic and orthotic services influenced by the training of staff providing them? Scoping review. A structured search of the peer-reviewed literature catalogued in major electronic databases yielded 3039 papers. Following review of title and abstract, 93 articles were considered relevant. Full-text review reduced this number to 25. Only two articles were identified as providing direct evidence of the effects of training and education on service provision. While both suggested that there was an impact, it is difficult to see how the more specific conclusions of either could be generalised. The other 23 articles provide a useful background to a range of issues including the specification of competencies that training programmes should deliver (3 articles), descriptions of a range of training programmes and the effects of training and education on student knowledge and skills. Although it is considered axiomatic, the service quality is dependent on practitioner education and training. There is insufficient evidence to establish whether levels of training and education in prosthetics and orthotics have an effect on the quality of prosthetic and orthotic services. Clinical relevance There is very little evidence about the effects of training and education of prosthetists and orthotists on service quality. While this is a somewhat negative finding, we feel that it is important to bring this to the attention of the prosthetics and orthotics community.

  16. First-in-man demonstration of a fully implanted myoelectric sensors system to control an advanced electromechanical prosthetic hand.

    Science.gov (United States)

    Pasquina, Paul F; Evangelista, Melissa; Carvalho, A J; Lockhart, Joseph; Griffin, Sarah; Nanos, George; McKay, Patricia; Hansen, Morten; Ipsen, Derek; Vandersea, James; Butkus, Josef; Miller, Matthew; Murphy, Ian; Hankin, David

    2015-04-15

    Advanced motorized prosthetic devices are currently controlled by EMG signals generated by residual muscles and recorded by surface electrodes on the skin. These surface recordings are often inconsistent and unreliable, leading to high prosthetic abandonment rates for individuals with upper limb amputation. Surface electrodes are limited because of poor skin contact, socket rotation, residual limb sweating, and their ability to only record signals from superficial muscles, whose function frequently does not relate to the intended prosthetic function. More sophisticated prosthetic devices require a stable and reliable interface between the user and robotic hand to improve upper limb prosthetic function. Implantable Myoelectric Sensors (IMES(®)) are small electrodes intended to detect and wirelessly transmit EMG signals to an electromechanical prosthetic hand via an electro-magnetic coil built into the prosthetic socket. This system is designed to simultaneously capture EMG signals from multiple residual limb muscles, allowing the natural control of multiple degrees of freedom simultaneously. We report the status of the first FDA-approved clinical trial of the IMES(®) System. This study is currently in progress, limiting reporting to only preliminary results. Our first subject has reported the ability to accomplish a greater variety and complexity of tasks in his everyday life compared to what could be achieved with his previous myoelectric prosthesis. The interim results of this study indicate the feasibility of utilizing IMES(®) technology to reliably sense and wirelessly transmit EMG signals from residual muscles to intuitively control a three degree-of-freedom prosthetic arm. Copyright © 2014 Elsevier B.V. All rights reserved.

  17. Mechanical instability and titanium particles induce similar transcriptomic changes in a rat model for periprosthetic osteolysis and aseptic loosening

    Directory of Open Access Journals (Sweden)

    Mehdi Amirhosseini

    2017-12-01

    Full Text Available Wear debris particles released from prosthetic bearing surfaces and mechanical instability of implants are two main causes of periprosthetic osteolysis. While particle-induced loosening has been studied extensively, mechanisms through which mechanical factors lead to implant loosening have been less investigated. This study compares the transcriptional profiles associated with osteolysis in a rat model for aseptic loosening, induced by either mechanical instability or titanium particles. Rats were exposed to mechanical instability or titanium particles. After 15 min, 3, 48 or 120 h from start of the stimulation, gene expression changes in periprosthetic bone tissue was determined by microarray analysis. Microarray data were analyzed by PANTHER Gene List Analysis tool and Ingenuity Pathway Analysis (IPA. Both types of osteolytic stimulation led to gene regulation in comparison to unstimulated controls after 3, 48 or 120 h. However, when mechanical instability was compared to titanium particles, no gene showed a statistically significant difference (fold change ≥ ±1.5 and adjusted p-value ≤ 0.05 at any time point. There was a remarkable similarity in numbers and functional classification of regulated genes. Pathway analysis showed several inflammatory pathways activated by both stimuli, including Acute Phase Response signaling, IL-6 signaling and Oncostatin M signaling. Quantitative PCR confirmed the changes in expression of key genes involved in osteolysis observed by global transcriptomics. Inflammatory mediators including interleukin (IL-6, IL-1β, chemokine (C-C motif ligand (CCL2, prostaglandin-endoperoxide synthase (Ptgs2 and leukemia inhibitory factor (LIF showed strong upregulation, as assessed by both microarray and qPCR. By investigating genome-wide expression changes we show that, despite the different nature of mechanical implant instability and titanium particles, osteolysis seems to be induced through similar biological

  18. Impact of pannus formation on hemodynamic dysfunction of prosthetic aortic valve: pannus extent and its relationship to prosthetic valve motion and degree of stenosis.

    Science.gov (United States)

    Koo, Hyun Jung; Ha, Hojin; Kang, Joon-Won; Kim, Jeong A; Song, Jae-Kwan; Kim, Hwa Jung; Lim, Tae-Hwan; Yang, Dong Hyun

    2018-02-19

    Although pannus is an important cause of prosthetic valve dysfunction, the minimum pannus size that can induce hemodynamic dysfunction has not yet been determined. This study investigated the correlation between the limitation of motion (LOM) of the prosthetic valve and pannus extent and determined the pannus extent that could induce severe aortic stenosis. This study included 49 patients who underwent mechanical aortic valve replacement (AVR) and showed pannus on cardiac computed tomography (CT). Pannus width, ratio of pannus width to valve diameter, pannus area, effective orifice area, encroachment ratio by pannus, pannus involvement angle and percent LOM of mechanical valves were evaluated on CT. Transvalvular peak velocity (TPV) and transvalvular pressure gradient (TPG) were measured by transesophageal echocardiography to determine the degree of aortic stenosis. The relationship between percent LOM of the prosthetic valve and pannus extent and the cut-off of pannus extent required to induce severe aortic stenosis were evaluated. The mean interval between AVR and pannus formation was 11 years and was longer in patients with than without severe aortic stenosis (14.0 vs. 7.3 years). On CT, the percent LOM of the prosthetic valve was significantly associated with the extent of pannus only in patients with pannus involvement angle > 180° (r = 0.55-0.68, P Pannus width, effective orifice area, and encroachment ratio were significantly associated with increased TPV and TPG (r = 0.51-0.62, P Pannus width > 3.5 mm, pannus width/valve inner diameter > 0.15, and encroachment ratio > 0.14 were significantly associated with severe aortic stenosis (TPV > 4 m/s; mean TPG ≥ 35 mmHg), with c-indices of 0.74-079 (P pannus extent parameters are good indicators of significant hemodynamic changes with increased TPV and mean TPG.

  19. The clinical significance of perivalvular pannus in prosthetic mitral valves: Can cardiac CT be helpful?

    Science.gov (United States)

    Chang, Suyon; Suh, Young Joo; Han, Kyunghwa; Kim, Jin Young; Kim, Young Jin; Chang, Byung-Chul; Choi, Byoung Wook

    2017-12-15

    The clinical significance of pannus in the prosthetic mitral valve (MV) is not well documented. To investigate the clinical significance of pannus on cardiac computed tomography (CT) in patients with a prosthetic MV. A total of 130 patients with previous MV replacement who underwent cardiac CT were retrospectively included in this study. The presence of pannus, paravalvular leak (PVL) around the prosthetic MV and limitation of motion (LOM) of the MV were analyzed using CT. Between patients with MV pannus and those without pannus, CT, echocardiographic, and redo-surgery findings were compared. The diagnostic performance of CT and transesophageal echocardiography (TEE) for the detection of MV pannus was also compared, using surgical findings as a standard reference. MV pannus was observed on cardiac CT in 32.3% of the study population. Patients with MV pannus detected on CT more commonly had LOM (28.2% vs. 15.2%) and less frequently had PVL of the prosthetic MV (16.7% vs. 25%) than patients without MV pannus (P>0.05). Prosthetic valve obstruction (PVO) due prosthetic MV pannus requiring redo-surgery was present in only five patients (11.9%). Cardiac CT detected MV pannus with sensitivity of 65.2% and specificity of 80.9% and showed better diagnostic performance than TEE (Ppannus can frequently be seen on cardiac CT. However, its clinical significance should be assessed with careful consideration, because PVO due to MV pannus is relatively uncommon, and pannus can be seen in patients without any clinical problems. Copyright © 2017 Elsevier B.V. All rights reserved.

  20. An evaluation of prosthetic status and treatment needs among institutionalized elderly individuals of Delhi, India

    Directory of Open Access Journals (Sweden)

    Nisha Yadav

    2017-01-01

    Full Text Available Context: Oral health is essential for elderly person's general health and well-being. The most common oral problem in elderly is tooth loss which results due to periodontal diseases and caries. Prosthetic status is very important as it is related to dietary intake and maintaining nutritional status. Hence, to promote the oral health of the elderly, we need to know their prosthetic status and need. Aims: The aim of this study is to find the prosthetic status and need of 65–74 years old elderly residing in old age homes of Delhi, India. Settings and Design: A cross-sectional study was conducted among a total of 464 residents of 20 old age homes of Delhi, India. Material and Methods: Residents with age group of 64–75 were included in the study. The prosthetic status with treatment need was recorded using the World Health Organization Oral Health Assessment Form (1997. Statistical Analysis Used: Chi-square test and t-test were used to find significance of variables. P < 0.05 was considered significant. Results: Full removable dentures were worn by 7.30% of participants with predominance in upper arch, and one bridge was seen in 9.10% of participants with predominance in lower arch. Full removable denture was required in 25.20% of participants. Most of participants required multiunit prosthesis in both upper as well as lower arch (42.20% and 36.20%, respectively. Conclusion: The present study underlines a considerable need for dental treatment in elderly as the prosthetic status of participants was poor, and prosthetic needs were high.

  1. Prosthetic Smart Socket Technology to Improve Patient Interaction, Usability, Comfort, Fit and Function

    Science.gov (United States)

    2017-10-01

    impact on society beyond science and technology ? Nothing to report at this time. 5. CHANGES/PROBLEMS: Changes in approach and reasons for...AWARD NUMBER: W81XWH-16-1-0785 TITLE: Prosthetic Smart Socket Technology to Improve Patient Interaction, Usability, Comfort, Fit and Function...2016 - 29 Sep 2017 4. TITLE AND SUBTITLE Prosthetic Smart Socket Technology to Improve Patient Interaction, Usability, Comfort, Fit and Function 5a

  2. From satisfaction to expectation: the patient's perspective in lower limb prosthetic care.

    Science.gov (United States)

    Van der Linde, Harmen; Hofstad, Cheriel J; Geertzen, Jan H B; Postema, Klaas; Van Limbeek, Jacques

    2007-07-15

    To obtain information about the wishes and experiences of patients with a lower limb amputation with regard to prosthetic prescription and their exchange of information with the healthcare providers. Cross-sectional questionnaire. Outpatient clinic of a Rehabilitation Centre. A random sample of patients with a lower limb amputation (n = 81). In analogy with the QUOTE questionnaire a focus group technique was used. Prosthetic users formulated 24 specific items, which were of importance according to them. The items were divided into 4 categories: (i) service demand, (ii) prosthetic prescription, (iii) information, (iv) insurance aspects. The questionnaire consisted of two sets (A and B) of 24 items rating importance of items and experience in everyday practice. To identify different dimensions within the 24 items, a factor analysis in SPSS was performed for lists A and B followed by a varimax rotation. Impact factors were calculated by multiplying the mean score of importance on an item with the percentage of patients that experienced this item as negative. A total of 113 questionnaires were sent by e-mail with a response of 73%. The outcomes of the questionnaires resulted in 2 sets of information: One concerning the importance of several items in the process of prosthetic prescription, the other the experience of the prosthetic user about those items. By multiplying the scores on importance by the percentage of negative experience per item (impact score) points of improvement for clinical practice were formulated. A discrepancy between the needs of patients and what they experience in their contacts with clinical professionals as the most important dimension was noticed. A questionnaire with specific items for a homogeneous target group is a good method to formulate points of improvement for clinical practice in healthcare.

  3. Process for making a titanium diboride-chromium diboride-yttrium titanium oxide ceramic composition

    Science.gov (United States)

    Holcombe, C.E.; Dykes, N.L.

    1992-04-28

    A ceramic composition is described. The ceramic composition consists essentially of from about 84 to 96 w/o titanium diboride, from about 1 to 9 w/o chromium diboride, and from about 3 to about 15 w/o yttrium-titanium-oxide. A method of making the ceramic composition is also described. The method of making the ceramic composition comprises the following steps: Step 1--A consolidated body containing stoichiometric quantities of titanium diboride and chromium diboride is provided. Step 2--The consolidated body is enclosed in and in contact with a thermally insulated package of yttria granules having a thickness of at least 0.5 inches. Step 3--The consolidated body enclosed in the thermally insulated package of yttria granules is heated in a microwave oven with microwave energy to a temperature equal to or greater than 1,900 degrees centigrade to sinter and uniformly disperse yttria particles having a size range from about 1 to about 12 microns throughout the consolidated body forming a densified body consisting essentially of titanium diboride, chromium diboride, and yttrium-titanium-oxide. The resulting densified body has enhanced fracture toughness and hardness. No Drawings

  4. Multi-Disciplinary Antimicrobial Strategies for Improving Orthopaedic Implants to Prevent Prosthetic Joint Infections in Hip and Knee

    Science.gov (United States)

    Getzlaf, Matthew A.; Lewallen, Eric A.; Kremers, Hilal M.; Jones, Dakota L.; Bonin, Carolina A.; Dudakovic, Amel; Thaler, Roman; Cohen, Robert C.; Lewallen, David G.; van Wijnen, Andre J.

    2016-01-01

    Like any foreign object, orthopaedic implants are susceptible to infection when introduced into the human body. Without additional preventative measures, the absolute number of annual prosthetic joint infections will continue to rise, and may exceed the capacity of health care systems in the near future. Bacteria are difficult to eradicate from synovial joints due to their exceptionally diverse taxonomy, complex mechanistic attachment capabilities, and tendency to evolve antibiotic resistance. When a primary orthopaedic implant fails from prosthetic joint infection, surgeons are generally challenged by limited options for intervention. In this review, we highlight the etiology and taxonomic groupings of bacteria known to cause prosthetic joint infections, and examine their key mechanisms of attachment. We propose that antimicrobial strategies should focus on the most harmful bacteria taxa within the context of occurrence, taxonomic diversity, adhesion mechanisms, and implant design. Patient-specific identification of organisms that cause prosthetic joint infections will permit assessment of their biological vulnerabilities. The latter can be targeted using a range of antimicrobial techniques that exploit different colonization mechanisms including implant surface attachment, biofilm formation, and/or hematogenous recruitment. We anticipate that customized strategies for each patient, joint, and prosthetic component will be most effective at reducing prosthetic joint infections, including those caused by antibiotic-resistant and polymicrobial bacteria. PMID:26449208

  5. Obstructed bi-leaflet prosthetic mitral valve imaging with real-time three-dimensional transesophageal echocardiography.

    Science.gov (United States)

    Shimbo, Mai; Watanabe, Hiroyuki; Kimura, Shunsuke; Terada, Mai; Iino, Takako; Iino, Kenji; Ito, Hiroshi

    2015-01-01

    Real-time three-dimensional transesophageal echocardiography (RT3D-TEE) can provide unique visualization and better understanding of the relationship among cardiac structures. Here, we report the case of an 85-year-old woman with an obstructed mitral prosthetic valve diagnosed promptly by RT3D-TEE, which clearly showed a leaflet stuck in the closed position. The opening and closing angles of the valve leaflets measured by RT3D-TEE were compatible with those measured by fluoroscopy. Moreover, RT3D-TEE revealed, in the ring of the prosthetic valve, thrombi that were not visible on fluoroscopy. RT3D-TEE might be a valuable diagnostic technique for prosthetic mitral valve thrombosis. © 2014 Wiley Periodicals, Inc.

  6. Can we close large prosthetic space with orthodontics?

    Science.gov (United States)

    Mesko, Mauro Elias; Skupien, Jovito Adiel; Valentini, Fernanda; Pereira-Cenci, Tatiana

    2013-01-01

    For years, the treatment for the replacement of a missing tooth was a fixed dental prosthesis. Currently, implants are indicated to replace missing teeth due to high clinical success and with the advantage of not performing preparations in the adjacent tooth. Another option for space closure is the use of orthodontics associated to miniscrews for anchorage allowing better control of the orthodontic biomechanics and especially making possible closure of larger prosthetic spaces. Thus, this article describes two cases with indications and discussion of the advantages and disadvantages of using orthodontics for prosthetic spaces closure. The cases herein presented show that it is possible to close an space when there are available teeth in the adjacent area. It can be concluded that when a malocclusion is present there will be a strong trend to indicate space closure by orthodontic movement as it preserves natural teeth and seems a more physiological approach.

  7. The History of Nontraditional or Ectopic Placement of Reservoirs in Prosthetic Urology.

    Science.gov (United States)

    Perito, Paul; Wilson, Steven

    2016-04-01

    Reservoir placement during implantation of prosthetic urology devices has been problematic throughout the history of the surgical treatment of erectile dysfunction and urinary incontinence. We thought it would be interesting to review the history of reservoir placement leading up to current surgical techniques. To provide an overview of the past and present techniques for reservoir placement and discuss the evolutionary process leading to safe and effective placement of prosthetic reservoirs. We reviewed data pertaining to inflatable penile prosthesis (IPP) reservoirs and pressure-regulating balloons (PRB) in a chronological fashion, spanning 25 years. Main outcomes included a historical review of techniques for IPP reservoir and PRB placement leading to the subsequent incremental improvements in safety and efficacy when performing penile implants and artificial urinary sphincters. Prosthetic urologic reservoirs have traditionally been placed in the retropubic space. Over the years, urologists have attempted use of alternative spaces including peritoneal, epigastric, "ectopic," posterior to transversalis, and high submuscular. Current advances in prosthetic urologic reservoir placement allow safe and effective abdominal wall placement of reservoirs. These novel approaches appear to be so effective that urologists may now be able to cease using the traditional retropubic space for reservoir placement, even in the case of virgin pelves. Copyright © 2016 International Society for Sexual Medicine. Published by Elsevier Inc. All rights reserved.

  8. Magnetic Oculomotor Prosthetics for Acquired Nystagmus.

    Science.gov (United States)

    Nachev, Parashkev; Rose, Geoff E; Verity, David H; Manohar, Sanjay G; MacKenzie, Kelly; Adams, Gill; Theodorou, Maria; Pankhurst, Quentin A; Kennard, Christopher

    2017-10-01

    Acquired nystagmus, a highly symptomatic consequence of damage to the substrates of oculomotor control, often is resistant to pharmacotherapy. Although heterogeneous in its neural cause, its expression is unified at the effector-the eye muscles themselves-where physical damping of the oscillation offers an alternative approach. Because direct surgical fixation would immobilize the globe, action at a distance is required to damp the oscillation at the point of fixation, allowing unhindered gaze shifts at other times. Implementing this idea magnetically, herein we describe the successful implantation of a novel magnetic oculomotor prosthesis in a patient. Case report of a pilot, experimental intervention. A 49-year-old man with longstanding, medication-resistant, upbeat nystagmus resulting from a paraneoplastic syndrome caused by stage 2A, grade I, nodular sclerosing Hodgkin's lymphoma. We designed a 2-part, titanium-encased, rare-earth magnet oculomotor prosthesis, powered to damp nystagmus without interfering with the larger forces involved in saccades. Its damping effects were confirmed when applied externally. We proceeded to implant the device in the patient, comparing visual functions and high-resolution oculography before and after implantation and monitoring the patient for more than 4 years after surgery. We recorded Snellen visual acuity before and after intervention, as well as the amplitude, drift velocity, frequency, and intensity of the nystagmus in each eye. The patient reported a clinically significant improvement of 1 line of Snellen acuity (from 6/9 bilaterally to 6/6 on the left and 6/5-2 on the right), reflecting an objectively measured reduction in the amplitude, drift velocity, frequency, and intensity of the nystagmus. These improvements were maintained throughout a follow-up of 4 years and enabled him to return to paid employment. This work opens a new field of implantable therapeutic devices-oculomotor prosthetics-designed to modify eye

  9. A Control Strategy with Tactile Perception Feedback for EMG Prosthetic Hand

    Directory of Open Access Journals (Sweden)

    Changcheng Wu

    2015-01-01

    Full Text Available To improve the control effectiveness and make the prosthetic hand not only controllable but also perceivable, an EMG prosthetic hand control strategy was proposed in this paper. The control strategy consists of EMG self-learning motion recognition, backstepping controller with stiffness fuzzy observation, and force tactile representation. EMG self-learning motion recognition is used to reduce the influence on EMG signals caused by the uncertainty of the contacting position of the EMG sensors. Backstepping controller with stiffness fuzzy observation is used to realize the position control and grasp force control. Velocity proportional control in free space and grasp force tracking control in restricted space can be realized by the same controller. The force tactile representation helps the user perceive the states of the prosthetic hand. Several experiments were implemented to verify the effect of the proposed control strategy. The results indicate that the proposed strategy has effectiveness. During the experiments, the comments of the participants show that the proposed strategy is a better choice for amputees because of the improved controllability and perceptibility.

  10. 40 CFR 180.1195 - Titanium dioxide.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 23 2010-07-01 2010-07-01 false Titanium dioxide. 180.1195 Section 180.1195 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) PESTICIDE PROGRAMS... Titanium dioxide. Titanium dioxide is exempted from the requirement of a tolerance for residues in or on...

  11. Advances in cost effective processing of titanium

    International Nuclear Information System (INIS)

    Nelson, O.E.

    1993-01-01

    Recently an industry expert pointed out that one of the greatest hindrances to the growth of titanium usage has been the low percentage of material usable in the final product. Due to the extensive processing, forming, and machining operations typically performed on titanium, yield losses are high. This is especially true in aerospace applications where most titanium is used. In engine components, the start to finish ratio, known as the buy to fly ratio, is often as high as 7 to 1. This can be illustrated by looking at the use of titanium in Pratt and Whitney engines. In the JT-8D-217 used on Boeing's 737-200, the titanium buyweight is 5,385 pounds, whereas the finished titanium, flyweight is just 758 pounds. This start to finish ratio is 7.1:1, giving titanium 17.0% of total engine weight. (orig.)

  12. Electron beam melting of sponge titanium

    International Nuclear Information System (INIS)

    Kanayama, Hiroshi; Kusamichi, Tatsuhiko; Muraoka, Tetsuhiro; Onouye, Toshio; Nishimura, Takashi

    1991-01-01

    Fundamental investigations were done on electron beam (EB) melting of sponge titanium by using 80 kW EB melting furnace. Results obtained are as follows: (1) To increase the melting yield of titanium in EB melting of sponge titanium, it is important to recover splashed metal by installation of water-cooled copper wall around the hearth and to decrease evaporation loss of titanium by keeping the surface temperature of molten metal just above the melting temperature of titanium without local heating. (2) Specific power consumption of drip melting of pressed sponge titanium bar and hearth melting of sponge titanium are approximately 0.9 kWh/kg-Ti and 0.5-0.7 kWh/kg-Ti, respectively. (3) Ratios of the heat conducted to water-cooled mould in the drip melting and to water-cooled hearth in the hearth melting to the electron beam input power are 50-65% and 60-65%, respectively. (4) Surface defects of EB-melted ingots include rap which occurs when the EB output is excessively great, and transverse cracks when the EB output is excessively small. To prevent surface defects, the up-down withdrawal method is effective. (author)

  13. [Microbiological characteristics and patterns of resistance in prosthetic joint infections in a referral hospital].

    Science.gov (United States)

    Ortega-Peña, Silvestre; Colín-Castro, Claudia; Hernández-Duran, Melissa; López-Jácome, Esaú; Franco-Cendejas, Rafael

    2015-01-01

    The prosthetic joint infection is the most feared and catastrophic complication for cause severe physical damage to patients and, generates high economic costs. To describe the microbiological characteristics and to determine the resistance pattern in prosthetic joint infections in a reference hospital in Mexico. Patients whose prosthetic devices were withdrawn due to suspicion of septic and aseptic loosening were included. Cultures were performed to identify microorganisms and susceptibility analysis. Of the 111 patients included, 55% were diagnosed with prosthetic joint infection, with the most frequent prosthesis being of the hip (43%). Positive cultures were obtained in 97% of the infected cases, of which 75% were monomicrobial infections. The most frequent bacterial species isolated were: Staphylococcus epidermidis (31%), Enterococcus faecalis (16%), Staphylococcus aureus (13%), and Escherichia coli (8%). The resistance patterns for the Staphylococcus genus were: oxacillin (79%), erythromycin (45%) and ciprofloxacin (37%). Enterococcus faecalis showed a high percentage of resistance to erythromycin and clindamycin (86%), and fluoroquinolones (43%). The large majority (86%) of Escherichia coli were extended spectrum beta-lactamases positive, in addition to having high resistance to fluoroquinolones (86%), trimethoprim/sulfamethoxazole (86%) and gentamicin (72%). The microbiological characteristics found in prosthetic joint infections vary according to the hospitals. In this series, a high proportion of coagulase-negative Staphylococci and Enterococcus spp. were found, as well as a high bacterial resistance. Copyright © 2015 Academia Mexicana de Cirugía A.C. Published by Masson Doyma México S.A. All rights reserved.

  14. Prosthetic joint infection caused by Granulicatella adiacens: a case series and review of literature.

    Science.gov (United States)

    Quénard, Fanny; Seng, Piseth; Lagier, Jean-Christophe; Fenollar, Florence; Stein, Andreas

    2017-06-23

    Bone and joint infection involving Granulicatella adiacens is rare, and mainly involved in cases of bacteremia and infectious endocarditis. Here we report three cases of prosthetic joint infection involving G. adiacens that were successfully treated with surgery and prolonged antimicrobial treatment. We also review the two cases of prosthetic joint infection involving G. adiacens that are reported in the literature. Not all five cases of prosthetic joint infection caused by G. adiacens were associated with bacteremia or infectious endocarditis. Dental care before the onset of infection was observed in two cases. The median time delay between arthroplasty implantation and the onset of infection was of 4 years (ranging between 2 and 10 years). One of our cases was identified with 16srRNA gene sequencing, one case with MALDI-TOF mass spectrometry, and one case with both techniques. Two literature cases were diagnosed by 16srRNA gene sequencing. All five cases were cured after surgery including a two-stage prosthesis exchange in three cases, a one-stage prosthesis exchange in one case, and debridement, antibiotics, irrigation, and retention of the prosthesis in one case, and prolonged antimicrobial treatment. Prosthetic joint infection involving G. adiacens is probably often dismissed due to difficult culture or misdiagnosis, in particular in the cases of polymicrobial infection. Debridement, antibiotics, irrigation, and retention of the prosthesis associated with prolonged antimicrobial treatment (≥ 8 weeks) should be considered as a treatment strategy for prosthetic joint infection involving G. adiacens.

  15. Production of titanium tetrachloride

    International Nuclear Information System (INIS)

    Perillo, P.M.; Botbol, O.

    1990-01-01

    This report presents a summary of results from theoperation of a laboratory scale for the production in batches of approximately 100 gs of titanium tetrachloride by chlorination with chloroform and carbon tetrachloride between 340 deg C and 540 deg C. Chlorination agent vapors were passed through a quartz column reacting with titanium oxide powder agglomerated in little spheres. Obtained titanium tetrachloride was condensed in a condenser, taken in a ballon and then purified by fractional distillation. Optimun temperature for chloroform was 400 deg C with 74 % yield and for carbon tetrachloride was 500 deg C with 69 % yield. (Author) [es

  16. Transcatheter pulmonary valve replacement by hybrid approach using a novel polymeric prosthetic heart valve: proof of concept in sheep.

    Directory of Open Access Journals (Sweden)

    Ben Zhang

    Full Text Available Since 2000, transcatheter pulmonary valve replacement has steadily advanced. However, the available prosthetic valves are restricted to bioprosthesis which have defects like poor durability. Polymeric heart valve is thought as a promising alternative to bioprosthesis. In this study, we introduced a novel polymeric transcatheter pulmonary valve and evaluated its feasibility and safety in sheep by a hybrid approach.We designed a novel polymeric trileaflet transcatheter pulmonary valve with a balloon-expandable stent, and the valve leaflets were made of 0.1-mm expanded polytetrafluoroethylene (ePTFE coated with phosphorylcholine. We chose glutaraldehyde-treated bovine pericardium valves as control. Pulmonary valve stents were implanted in situ by a hybrid transapical approach in 10 healthy sheep (8 for polymeric valve and 2 for bovine pericardium valve, weighing an average of 22.5±2.0 kg. Angiography and cardiac catheter examination were performed after implantation to assess immediate valvular functionality. After 4-week follow-up, angiography, echocardiography, computed tomography, and cardiac catheter examination were used to assess early valvular function. One randomly selected sheep with polymeric valve was euthanized and the explanted valved stent was analyzed macroscopically and microscopically.Implantation was successful in 9 sheep. Angiography at implantation showed all 9 prosthetic valves demonstrated orthotopic position and normal functionality. All 9 sheep survived at 4-week follow-up. Four-week follow-up revealed no evidence of valve stent dislocation or deformation and normal valvular and cardiac functionality. The cardiac catheter examination showed the peak-peak transvalvular pressure gradient of the polymeric valves was 11.9±5.0 mmHg, while that of two bovine pericardium valves were 11 and 17 mmHg. Gross morphology demonstrated good opening and closure characteristics. No thrombus or calcification was seen macroscopically

  17. [Intra-prosthetic dislocation of the Bousquet dual mobility socket].

    Science.gov (United States)

    Lecuire, F; Benareau, I; Rubini, J; Basso, M

    2004-05-01

    The Bousquet system is a dual mobility head-polyethylene polyethylene-metal cup socket. The polyethylene insert retaining the femoral head moves in the noncemented metal cup, increasing both mobility and stability. Between 1989 and 1997, seven cases of intra-prosthetic dislocation (six patients) were observed. The femoral head escaped from the polyethylene insert due to wear. On the average, this complication occurred ten Years after implantation. Risk of dislocation was high in six of the seven hips. All patients had a large sized stem screwed into the femoral neck. There was a characteristic radiological aspect with loss of the concentric head metal cup configuration. The head was applied against the upper wall of the metal cup. Surgical replacement was undertaken early in six patients by simply changing the insert without modifying the other stable components. Outcome remained good at three to eight Years. One patient underwent late surgery. The insert and the cup were replaced with a classical implant. Functional outcome was good but recurrent dislocation occurred. At mid-term, intra-prosthetic dislocation of dual mobility sockets appears to be exceptional. Dislocation results from polyethylene wear leading to failure of the insert to retain the prosthetic head. Wear is favored by direct phenomena (direct contact between neck and insert which can occur early if there is a small difference in the head and neck diameters) or indirect phenomena (factors limiting polyethylene metal-cup mobility). Surgical treatment is necessary. If undertaken early, replacement with a modular head and insert can be sufficient if the prosthesis has not loosened but the metal cup may have to be replaced in the event of metal-metal contact between the head and the cup. Prosthesis loosening, wear of the metal cup, or an identified cause of dislocation imply replacing the failing implants. Implantation of the dual mobility system is particularly interesting for patients with a high risk

  18. Extrinsic mechanism obstructing the opening of a prosthetic mitral valve: an unusual case of suture entrapment.

    Science.gov (United States)

    Ozkan, Mehmet; Astarcioglu, Mehmet Ali; Karakoyun, Suleyman; Balkanay, Mehmet

    2012-02-01

    Obstruction to a prosthetic cardiac valve is a well-recognized complication of cardiac valve replacement. Malfunction of the mobile component of a prosthetic valve to open or close correctly may occur in consequence of intrinsic or extrinsic causes (thrombus, vegetation, entrapment of left ventricular myocardium, suture entanglement, and pannus formation) that may result prosthetic valve stenosis and/or insufficiency. In the case we report a 48-year-old female with valve dysfunction occurred early after surgery, as one valve leaflet was only able to partially open due to suture entrapment. © 2011, Wiley Periodicals, Inc.

  19. Prosthetic Management of Patients Presenting with Juvenile ...

    African Journals Online (AJOL)

    Eighteen were referred for prosthetic replacement. Their age ranged between 18 and 36 years. A total of 24 removable partial dentures were fabricated, 17[70.8%] were kennedy class III type, of which 11[64.7%] had the bounded saddle located in the anterior segment. Majority 8[44.4%] of the patients had 2-4 teeth replaced ...

  20. Uranium fluorides analysis. Titanium spectrophotometric determination

    International Nuclear Information System (INIS)

    Anon.

    Titanium determination in uranium hexafluoride in the range 0.7 to 100 microgrammes after transformation of uranium fluoride in sulfate. Titanium is separated by extraction with N-benzoylphenylhydroxylamine, reextracted by hydrochloric-hydrofluoric acid. The complex titanium-N-benzoylphenylhydroxylamine is extracted by chloroform. Spectrophotometric determination at 400 nm [fr

  1. 21 CFR 73.2575 - Titanium dioxide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Titanium dioxide. 73.2575 Section 73.2575 Food and... ADDITIVES EXEMPT FROM CERTIFICATION Cosmetics § 73.2575 Titanium dioxide. (a) Identity and specifications. The color additive titanium dioxide shall conform in identity and specifications to the requirements...

  2. Pseudotumor of the Hip due to Fungal Prosthetic Joint Infection

    Directory of Open Access Journals (Sweden)

    Stefano Artiaco

    2013-01-01

    Full Text Available Pseudotumors associated with total hip arthroplasty have been associated with metal-on-metal and metal-on-polyethylene total hip arthroplasties due to a granulomatous foreign-body reaction to methyl methacrylate, polyethylene, or metal ion release, but they have not been related to prosthetic joint infections. In this paper, we report an unusual case of Candida albicans total hip arthroplasty infection, causing a large inflammatory pseudotumor of the hip joint. Fungal periprosthetic joint infections are a rare clinical entity and difficult to diagnose, and a pseudotumor may be part of their clinical presentation. They should be suspected in immunodeficient host patients when clinical symptoms of prosthetic joint infections are observed.

  3. Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

    Science.gov (United States)

    Cianciulli, Tomás F; Lax, Jorge A; Saccheri, María C; Guidoin, Robert; Salvado, César M; Fernández, Adrián J; Prezioso, Horacio A

    2008-01-01

    The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

  4. A geometrical optimization of a magneto-rheological rotary brake in a prosthetic knee

    International Nuclear Information System (INIS)

    Gudmundsson, K H; Jonsdottir, F; Thorsteinsson, F

    2010-01-01

    Magneto-rheological (MR) fluids have been successfully introduced to prosthetic devices. One such device is a biomechanical prosthetic knee that uses MR fluids to actively control its rotary stiffness. The brake is rotational, utilizing the MR fluid in shear mode. In this study, the geometrical design of the MR brake is addressed. This includes the design of the magnetic circuit and the geometry of the fluid chamber. Mathematical models are presented that describe the rotary torque of the brake. A novel perfluorinated polyether (PFPE)-based MR fluid is introduced, whose properties are tailored for the prosthetic knee. On-state and off-state rheological measurements of the MR fluid are presented. The finite element method is used to evaluate the magnetic flux density in the MR fluid. The design is formulated as an optimization problem, aiming to maximize the braking torque. A parametric study is carried out for several design parameters. Subsequently, a multi-objective optimization problem is defined that considers three design objectives: the field-induced braking torque, the off-state rotary stiffness and the weight of the brake. Trade-offs between the three design objectives are investigated which provides a basis for informed design decisions on furthering the success of the MR prosthetic knee

  5. Titanium oxide nanocoating on a titanium thin film deposited on a glass substrate

    Energy Technology Data Exchange (ETDEWEB)

    Kotsedi, L., E-mail: kotsedi@tlabs.ac.za [UNESCO-UNISA Africa Chair in Nanosciences-Nanotechnology, College of Graduate Studies, University of South Africa, Muckleneuk Ridge, PO Box 392, Pretoria (South Africa); Nanosciences African Network (NANOAFNET), iThemba LABS, National Research Foundation, 1 Old Faure Road, Somerset West 7129, PO Box 722, Somerset West, Western Cape (South Africa); Nuru, Z.Y. [UNESCO-UNISA Africa Chair in Nanosciences-Nanotechnology, College of Graduate Studies, University of South Africa, Muckleneuk Ridge, PO Box 392, Pretoria (South Africa); Nanosciences African Network (NANOAFNET), iThemba LABS, National Research Foundation, 1 Old Faure Road, Somerset West 7129, PO Box 722, Somerset West, Western Cape (South Africa); Eaton, S.M. [Physics Department, Politecnico di Milano, Piazza Leonardo Da Vinci, 32, 20133 Milano (Italy); Cummings, F.R. [University of the Western Cape, Electron Microscopy Unit, Physics Department, Bellville 7535, Cape Town (South Africa); Turco, S. Lo; Ntwaeaborwa, O.M. [Center for Nano Science and Technology, Istituto Italiano di Tecnologia, Milano, Italy Via Giovanni Pascoli, 70/3, 20133 Milano (Italy); Ramponi, R. [Institute for Photonics and Nanotechnologies (IFN)-CNR, Piazza Leonardo Da Vinci, 32, 20133 Milano (Italy); Maaza, M. [UNESCO-UNISA Africa Chair in Nanosciences-Nanotechnology, College of Graduate Studies, University of South Africa, Muckleneuk Ridge, PO Box 392, Pretoria (South Africa); Nanosciences African Network (NANOAFNET), iThemba LABS, National Research Foundation, 1 Old Faure Road, Somerset West 7129, PO Box 722, Somerset West, Western Cape (South Africa)

    2016-03-31

    Thin films of titanium were deposited on a glass substrate using electron beam evaporator. Femtosecond laser pulses were focused on the surface of the films, and the samples were scanned while mounted on the motorized computer-controlled motion stage to produce an areal modification of the films. X-ray diffraction of the laser-patterned samples showed evidence of the formation of a γ-Ti{sub 3}O{sub 5} with a monoclinic phase. Rutherford backscattering spectrometry simulation showed that there is an increase in the oxygen concentration as the average laser fluence is increased. Time of flight secondary ions mass spectrometry analysis showed an even distribution of the titanium and oxygen ions on the sample and also ionized molecules of the oxides of titanium were observed. The formation of the oxide of titanium was further supported using the UV–Vis-NIR spectroscopy, which showed that for 0.1 J/cm{sup 2} fluence, the laser-exposed film showed the electron transfer band and the d–d transition peak of titanium was observed at lower wavelengths. - Highlights: • γ-Ti{sub 3}O{sub 5} formed using femtosecond laser. • Fluence and oxygen relation were studied. • Nanoflakes of γ-Ti{sub 3}O{sub 5} were observed under HRSEM.

  6. 21 CFR 73.1575 - Titanium dioxide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Titanium dioxide. 73.1575 Section 73.1575 Food and... ADDITIVES EXEMPT FROM CERTIFICATION Drugs § 73.1575 Titanium dioxide. (a) Identity and specifications. (1) The color additive titanium dioxide shall conform in identity and specifications to the requirements...

  7. Prosthetic joint infection due to Lysobacter thermophilus diagnosed by 16S rRNA gene sequencing

    OpenAIRE

    B Dhawan; S Sebastian; R Malhotra; A Kapil; D Gautam

    2016-01-01

    We report the first case of prosthetic joint infection caused by Lysobacter thermophilus which was identified by 16S rRNA gene sequencing. Removal of prosthesis followed by antibiotic treatment resulted in good clinical outcome. This case illustrates the use of molecular diagnostics to detect uncommon organisms in suspected prosthetic infections.

  8. Adhesive-Bonded Tab Attaches Thermocouples to Titanium

    Science.gov (United States)

    Cook, C. F.

    1982-01-01

    Mechanical strength of titanium-alloy structures that support thermocouples is preserved by first spotwelding thermocouples to titanium tabs and then attaching tabs to titanium with a thermosetting adhesive. In contrast to spot welding, a technique previously used for thermocouples, fatigue strength of the titanium is unaffected by adhesive bonding. Technique is also gentler than soldering or attaching thermocouples with a tap screw.

  9. Scintigraphic detection of prosthetic joint and soft tissue sepsis secondary to tuberculosis

    International Nuclear Information System (INIS)

    Zeiger, L.S.; Watters, W.; Sherk, H.

    1984-01-01

    In a 40-year-old Hispanic woman with pain and swelling in the left knee with a prosthesis, the combination of Ga-67 citrate and Tc-99m methylene diphosphonate (MDP) scans was used to indicate that there was a septic prosthetic joint. At surgery, the joint was infected and a foreign body was found. Cultures positive for tuberculosis were found also. The presence of an incongruent Ga-67 and Tc-99m (MDP) scan pattern suggests infection of the prosthetic joint, as in the following case

  10. Prosthetic prescription in the Netherlands : an observational study

    NARCIS (Netherlands)

    van der Linde, H; Geertzen, JHB; Hofstad, CJ; Postema, K; Van Limbeek, Jacques

    2003-01-01

    Prosthetic prescription for lower limb amputees and the methodology used are primarily based on empirical knowledge. Clinical expertise plays an important role that can lead to an adequate prescription; however, a clear evidence based motivation for the choices made cannot be given. This can lead to

  11. 21 CFR 872.3640 - Endosseous dental implant.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Endosseous dental implant. 872.3640 Section 872...) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3640 Endosseous dental implant. (a) Identification. An endosseous dental implant is a device made of a material such as titanium or titanium alloy, that...

  12. Resource-efficient proces chains to manufacture patient-specific prosthetic fingers

    Directory of Open Access Journals (Sweden)

    Hagedorn-Hansen, D.

    2016-05-01

    Full Text Available The high cost of quality prostheses, together with the lack of trained prosthetists, makes it challenging to obtain prosthetic devices in developing communities. Modern 3D digitising techniques and additive manufacturing (AM technologies are gaining popularity in the bio-medical industry and, in the case of prosthesis production, reduce the need for a trained prosthetist. The objective of this research was to develop a new resource-efficient process chain for the manufacturing of prosthetic fingers using additive manufacturing technologies, and to compare it with the traditional (Sculptor process chain. Fused deposition modelling (FDM, open-source FDM, 3-dimensional printing (3DP, and stereolithography (SLA were evaluated in terms of their costs, time, material usage, and aesthetic quality. The surface qualities produced with the different additive manufacturing technologies were also compared. The results showed that 3DP was the preferred technology and was the best candidate for the production of prosthesis in terms of cost, quality, and time for developing communities. SLA produced the highest aesthetic quality prosthesis, but was the most expensive. It was concluded that using the additive manufacturing technology process chain to produce prosthetic fingers is faster and more cost effective than the traditional method.

  13. Simulation Techniques and Prosthetic Approach Towards Biologically Efficient Artificial Sense Organs- An Overview

    OpenAIRE

    Neogi, Biswarup; Ghosal, Soumya; Mukherjee, Soumyajit; Das, Achintya; Tibarewala, D. N.

    2011-01-01

    An overview of the applications of control theory to prosthetic sense organs including the senses of vision, taste and odor is being presented in this paper. Simulation aspect nowadays has been the centre of research in the field of prosthesis. There have been various successful applications of prosthetic organs, in case of natural biological organs dis-functioning patients. Simulation aspects and control modeling are indispensible for knowing system performance, and to generate an original a...

  14. The use of ceramic in prosthetic hip surgery. The state of the art.

    Science.gov (United States)

    Toni, A; Terzi, S; Sudanese, A; Tabarroni, M; Zappoli, F A; Stea, S; Giunti, A

    1995-01-01

    The authors review current knowledge regarding the use of ceramic materials in prosthetic hip surgery, both as constituents of prosthetic components, and as materials used to coat metallic surfaces. A review of the literature defines the advantages and disadvantages to using ceramic-polyethylene or ceramic-ceramic combinations, based on the possibility that alumina coating may favor localized bone demineralization, and on the first promising clinical results of the use of hydroxyapatite coating.

  15. Criterion of titanium aviation alloy application

    International Nuclear Information System (INIS)

    Stasyunas, O.P.

    1976-01-01

    The most significant statistic mechanical characteristics are presented of titanium as compared with those of aluminium and steel. Based on these data one can draw conclusions as to the advantages and disadvantages of titanium. High chemical activity and diffusivity of titanium place limitations on the use of its alloys. Despite the promising features of a needle-like structure, specifications still keep relying on a globular structure, which is explained by the easeiness of the production. Titanium is expensive, sometimes its cost may by a factor of 20 exceed that of other aviation materials

  16. Cyborg beast: a low-cost 3d-printed prosthetic hand for children with upper-limb differences.

    Science.gov (United States)

    Zuniga, Jorge; Katsavelis, Dimitrios; Peck, Jean; Stollberg, John; Petrykowski, Marc; Carson, Adam; Fernandez, Cristina

    2015-01-20

    There is an increasing number of children with traumatic and congenital hand amputations or reductions. Children's prosthetic needs are complex due to their small size, constant growth, and psychosocial development. Families' financial resources play a crucial role in the prescription of prostheses for their children, especially when private insurance and public funding are insufficient. Electric-powered (i.e., myoelectric) and body-powered (i.e., mechanical) devices have been developed to accommodate children's needs, but the cost of maintenance and replacement represents an obstacle for many families. Due to the complexity and high cost of these prosthetic hands, they are not accessible to children from low-income, uninsured families or to children from developing countries. Advancements in computer-aided design (CAD) programs, additive manufacturing, and image editing software offer the possibility of designing, printing, and fitting prosthetic hands devices at a distance and at very low cost. The purpose of this preliminary investigation was to describe a low-cost three-dimensional (3D)-printed prosthetic hand for children with upper-limb reductions and to propose a prosthesis fitting methodology that can be performed at a distance. No significant mean differences were found between the anthropometric and range of motion measurements taken directly from the upper limbs of subjects versus those extracted from photographs. The Bland and Altman plots show no major bias and narrow limits of agreements for lengths and widths and small bias and wider limits of agreements for the range of motion measurements. The main finding of the survey was that our prosthetic device may have a significant potential to positively impact quality of life and daily usage, and can be incorporated in several activities at home and in school. This investigation describes a low-cost 3D-printed prosthetic hand for children and proposes a distance fitting procedure. The Cyborg Beast

  17. Indium-granulocyte scanning in the painful prosthetic joint

    International Nuclear Information System (INIS)

    Pring, D.J.; Henderson, R.G.; Keshavarzian, A.; Rivett, A.G.; Krausz, T.; Coombs, R.R.; Lavender, J.P.

    1986-01-01

    The value of indium-111-labeled granulocyte scanning to determine the presence of infection was assessed in 50 prosthetic joints (41 of which were painful) in 40 patients. Granulocytes were obtained from the patients' blood and labeled in plasma with indium 111 tropolonate. Abnormal accumulation of indium 111 in the region of the prosthesis was noted. Proven infection occurred in 11 prostheses, and all of the infections were detected by indium-111-labeled granulocyte scanning. Nineteen were not infected (including nine asymptomatic controls) and only two produced false-positive scans. This represents a specificity of 89.5%, sensitivity of 100%, and overall accuracy of 93.2%. These results compare favorably with plain radiography. There was no radiologic evidence of infection in three of the infected prostheses, and 10 of the noninfected prostheses had some radiologic features that suggested sepsis. We conclude that indium-granulocyte scanning can reliably detect or exclude infection in painful prosthetic joints and should prove useful in clinical management

  18. 21 CFR 73.575 - Titanium dioxide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Titanium dioxide. 73.575 Section 73.575 Food and... ADDITIVES EXEMPT FROM CERTIFICATION Foods § 73.575 Titanium dioxide. (a) Identity. (1) The color additive titanium dioxide is synthetically prepared TiO2, free from admixture with other substances. (2) Color...

  19. 21 CFR 73.3126 - Titanium dioxide.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Titanium dioxide. 73.3126 Section 73.3126 Food and... ADDITIVES EXEMPT FROM CERTIFICATION Medical Devices § 73.3126 Titanium dioxide. (a) Identity and specifications. The color additive titanium dioxide (CAS Reg. No. 13463-67-7), Color Index No. 77891, shall...

  20. Reduction electric smelting of ferriferrous-titanium concentrates from Gremyakha-Vyrmes deposit

    International Nuclear Information System (INIS)

    Morozov, A.A.

    2002-01-01

    Substantial composition of ilmenite and titanium-magnetite concentrates from Gremyaha-Vyrmes deposit is studied and their reducibility is examined as compared with other similar kids of raw materials. Thermal-physical properties of slag melts (such as toughness and melting ability), formed in reduction smelting of the above-mentioned concentrates for different reduction degree, are determined. These properties characterize the electric thermal transformation process of concentrates as hi-tech one. Features of chemical composition of metal, which is naturally alloyed with vanadium and is produced at the same time are noted. This metal expands the possibilities of complex used of the concentrates of this deposit [ru

  1. CT Assessment of the axial deviation of the femoral and tibial prosthetic components in total knee arthroplasty

    International Nuclear Information System (INIS)

    Rimondi, E.; Molinari, M.; Moio, A.; Busacca, M.; Trentani, F.; Trentani, P.; Tigani, D.; Nigrosoli, M.

    2000-01-01

    CT assessment of the axial deviation of the femoral and tibial prosthetic components in total knee arthroplasty. From January to July 1999, 17 patients, 10 males and 7 females, mean age 66 years (standard deviation plus or minus 4) were examined after total knee arthroplasty. Exclusion criteriawere prosthesis loosening and severe (equal or superior to 7'' varus o valgus deviation. All patients were examined with knee radiography in the standing position completed by axial projection of patella and by CT scanning. It was used a modification of Berger technique and carried out comparative CT scans extended lower limbs and acquisitions perpendicular to the mechanical axis of the knee, from the femoral supracondylar region down to the plane crossing the distal end of the tibial prosthetic component. Reference lines were then drawn electronically on given scanning planes to reckon the axial deviation of the femoral and tibial prosthetic components. Six patients, one female and 5 males with normal rotational values of femoral and tibial prosthetic components presented no clinical symptoms. Eight patients, 4 females and 4 males, with abnormal values presented the following clinical symptoms: medial impingement, (incomplete) dislocation patella, and lateral instability. One female patient with a normal rotational value of femoral prosthetic component and an altered value of tibial prosthetic component presented medial impingement. Finally two patients, one female and one male, were absolutely asymptomatic although the rotational values of the two prosthetic components were beyond the normal range. Total knee arthroplasty is presently a standard treatment for many conditions involving this joint. There are several possible postoperative complications, namely fractures, dislocations (a)septic losening and femoropatellar instability. The latter condition is the most frequent complication among implant failures and is caused by bad orientation of the femoral and tibial

  2. Using virtual ridge augmentation and 3D printing to fabricate a titanium mesh positioning device: A novel technique letter.

    Science.gov (United States)

    Al-Ardah, Aladdin; Alqahtani, Nasser; AlHelal, Abdulaziz; Goodacre, Brian; Swamidass, Rajesh; Garbacea, Antoanela; Lozada, Jaime

    2018-05-02

    This technique describes a novel approach for planning and augmenting a large bony defect using a titanium mesh (TiMe). A 3-dimensional (3D) surgical model was virtually created from a cone beam computed tomography (CBCT) and wax-pattern of the final prosthetic outcome. The required bone volume (horizontally and vertically) was digitally augmented and then 3D printed to create a bone model. The 3D model was then used to contour the TiMe in accordance with the digital augmentation. With the contoured / preformed TiMe on the 3D printed model a positioning jig was made to aid the placement of the TiMe as planned during surgery. Although this technique does not impact the final outcome of the augmentation procedure, it allows the clinician to virtually design the augmentation, preform and contour the TiMe, and create a positioning jig reducing surgical time and error.

  3. Welding and Joining of Titanium Aluminides

    Science.gov (United States)

    Cao, Jian; Qi, Junlei; Song, Xiaoguo; Feng, Jicai

    2014-01-01

    Welding and joining of titanium aluminides is the key to making them more attractive in industrial fields. The purpose of this review is to provide a comprehensive overview of recent progress in welding and joining of titanium aluminides, as well as to introduce current research and application. The possible methods available for titanium aluminides involve brazing, diffusion bonding, fusion welding, friction welding and reactive joining. Of the numerous methods, solid-state diffusion bonding and vacuum brazing have been most heavily investigated for producing reliable joints. The current state of understanding and development of every welding and joining method for titanium aluminides is addressed respectively. The focus is on the fundamental understanding of microstructure characteristics and processing–microstructure–property relationships in the welding and joining of titanium aluminides to themselves and to other materials. PMID:28788113

  4. Orthodontic space closure versus prosthetic replacement of missing upper lateral incisors in patients with bilateral cleft lip and palate.

    Science.gov (United States)

    Oosterkamp, Barbara C M; Dijkstra, Pieter U; Remmelink, Hendrik J; van Oort, Robert P; Sandham, Andrew

    2010-11-01

    To compare dental aesthetics and function of orthodontic space closure versus prosthetic replacement of upper lateral incisors in patients with bilateral cleft lip and palate. The predominant mode of prosthetic replacement was resin-bonded bridges. The retrospective study group consisted of 17 patients treated with orthodontic space closure (13 men, four women; median age, 27.1 years; interquartile range, 20.6 to 33.3 years) and 10 patients treated with prosthetic replacement (five men, five women; median age, 27.7 years; interquartile range, 20.9 to 39.7 years). Dental aesthetics were evaluated by the patients and by a professional panel. Mandibular function was evaluated by means of the mandibular function impairment questionnaire. The level of mandibular impairment was calculated using the Function Impairment Rating Scale. With respect to dental aesthetics, no significant differences between patients treated with orthodontic space closure and prosthetic replacement were found. With respect to function, the level of mandibular impairment was significantly higher in patients treated with prosthetic replacement compared with patients treated with orthodontic space closure, as indicated by high scores on specific masticatory functions. Orthodontic space closure and prosthetic replacement in bilateral cleft lip and palate patients produce similar results in terms of aesthetics. In terms of function, prosthetic replacement results in significantly more impairment of specific masticatory functions.

  5. Comparative study of radiography and scintigraphy for loosening and infection of prosthetic hip replacement

    International Nuclear Information System (INIS)

    Park, Mi Sook; Lee, Sun Wha; Choi, Woo Suk; Lim, Joo Won; Song, Han Joon; Ahn, Chi Yul

    1987-01-01

    Prosthetic hip replacement is associated with certain complications which result in a painful hip. Many of these, e. g. prosthetic dislocation, fracture, trochanteric avulsion, and heterotopic calcification are easily diagnosed by conventional radiography. However, radiographic evaluation for infection and/pr loosening of prosthesis as major complications requiring reoperation often contributes little to the resolution of the diagnostic problem. The authors made a comparative study of plain radiography and scintigraphy of 39 cases performed revision at Kyung Hee University Hospital from Sep. '81-to Aug. '86. The results were as follows: 1. In 39 revised prosthetic hip replacement, 26 cases (67%) of loosening without infection and 11 cases (28%) of infection were proven. 2. In loosening of prosthesis, plain radiography showed true positive rate of 76% and true negative rate of 60%, and scintigraphy showed true positive rate of 75% and true negative rate of 95%. 3. In infection of prosthesis, plain radiography revealed true positive rate of 55% and true negative rate of 96%, and scintigraphy revealed true positive rate of 100% and true negative rate of 83%. 4. Scintigraphy and plain radiography were useful as complementary procedure in evaluating and differentiating loosening and/or infection of prosthetic component

  6. The effects of common footwear on stance-phase mechanical properties of the prosthetic foot-shoe system.

    Science.gov (United States)

    Major, Matthew J; Scham, Joel; Orendurff, Michael

    2018-04-01

    Prosthetic feet are prescribed based on their mechanical function and user functional level. Subtle changes to the stiffness and hysteresis of heel, midfoot, and forefoot regions can influence the dynamics and economy of gait in prosthesis users. However, the user's choice of shoes may alter the prosthetic foot-shoe system mechanical characteristics, compromising carefully prescribed and rigorously engineered performance of feet. Observe the effects of footwear on the mechanical properties of the prosthetic foot-shoe system including commonly prescribed prosthetic feet. Repeated-measures, Mechanical characterization. The stiffness and energy return was measured using a hydraulic-driven materials test machine across combinations of five prosthetic feet and four common shoes as well as a barefoot condition. Heel energy return decreased by an average 4%-9% across feet in all shoes compared to barefoot, with a cushioned trainer displaying the greatest effect. Foot designs that may improve perceived stability by providing low heel stiffness and rapid foot-flat were compromised by the addition of shoes. Shoes altered prosthesis mechanical characteristics in the sagittal and frontal planes, suggesting that shoe type should be controlled or reported in research comparing prostheses. Understanding of how different shoes could alter certain gait-related characteristics of prostheses may aid decisions on footwear made by clinicians and prosthesis users. Clinical relevance Shoes can alter function of the prosthetic foot-shoe system in unexpected and sometimes undesirable ways, often causing similar behavior across setups despite differences in foot design, and prescribing clinicians should carefully consider these effects on prosthesis performance.

  7. Tactile Sensing Reflexes for Advanced Prosthetic Hands

    Science.gov (United States)

    2016-10-01

    Jeremy A. Fishel, Member, IEEE Figure 1. A) Custom NumaTac prosthetic fingertip sensor core and foam; B) Ottobock VariPlus Speed hand installed with two...oal – H ardw are P rototype D evelopm ent R   Identify alternatives for outcom e m easures R   E xplore sensor design param eters C Y16 G oals – C

  8. Prosthetic finger phalanges with lifelike skin compliance for low-force social touching interactions

    Directory of Open Access Journals (Sweden)

    Ge Shuzhi

    2011-03-01

    Full Text Available Abstract Background Prosthetic arms and hands that can be controlled by the user's electromyography (EMG signals are emerging. Eventually, these advanced prosthetic devices will be expected to touch and be touched by other people. As realistic as they may look, the currently available prosthetic hands have physical properties that are still far from the characteristics of human skins because they are much stiffer. In this paper, different configurations of synthetic finger phalanges have been investigated for their skin compliance behaviour and have been compared with the phalanges of the human fingers and a phalanx from a commercially available prosthetic hand. Methods Handshake tests were performed to identify which areas on the human hand experience high contact forces. After these areas were determined, experiments were done on selected areas using an indenting probe to obtain the force-displacement curves. Finite element simulations were used to compare the force-displacement results of the synthetic finger phalanx designs with that of the experimental results from the human and prosthetic finger phalanges. The simulation models were used to investigate the effects of (a varying the internal topology of the finger phalanx and (b varying different materials for the internal and external layers. Results and Conclusions During handshake, the high magnitudes of contact forces were observed at the areas where the full grasping enclosure of the other person's hand can be achieved. From these areas, the middle phalanges of the (a little, (b ring, and (c middle fingers were selected. The indentation experiments on these areas showed that a 2 N force corresponds to skin tissue displacements of more than 2 mm. The results from the simulation model show that introducing an open pocket with 2 mm height on the internal structure of synthetic finger phalanges increased the skin compliance of the silicone material to 235% and the polyurethane material to

  9. METHODOLOGY OF PROSTHETIC TREATMENT IN PATIENTS WITH MAXILLECTOMY

    Directory of Open Access Journals (Sweden)

    Ivan Gerdzhikov

    2018-06-01

    Full Text Available Aim: The aim of the described method is to present the main stages in the prosthetic treatment with hollow bulb obturator, which provides optimum defect hermetization and restoration of the damaged functions. Materials and methods: The clinical case, described is on a 70-years-old patient with edentulous jaws and maxillary defect in the right half of the upper jaw. The preliminary impressions were taken with irreversible hydrocolloid impression material, and the final impressions were taken with additive silicone material. The occlusion height and the centric relations were registered as the classical technique. After the successful trial denture appointment, the surface of the plaster master model was covered by isolation polish. After this procedure, the master model was covered by even wax layer with 5mm thickness. It was designed to be thinner in the area of the resection line. The designed cavity was filled in with silicone impression material and covered with the folio. The base plate with the arranged teeth was fixed to the model, packed in the cuvette and finished from heat-cured acrylic resin with low quantity of residual monomer. After the polymerization process, the silicone material was removed, and the obturators cap was fixed to the denture’s base plate with cold cured acrylic resin. The obturator and the complete denture of the mandible were adjusted and articulated in patient’s mouth in the final clinical stage. Results: The applied prosthetic method allowed successful defect hermetization and helped for the restoration of the speech, feeding and patient’s self-esteem. Conclusion: Prosthetic rehabilitation of patients with maxillary resection is possible only with the application of specific treatment methods.

  10. Prosthetic joint infection due to Lysobacter thermophilus diagnosed by 16S rRNA gene sequencing

    Directory of Open Access Journals (Sweden)

    B Dhawan

    2016-01-01

    Full Text Available We report the first case of prosthetic joint infection caused by Lysobacter thermophilus which was identified by 16S rRNA gene sequencing. Removal of prosthesis followed by antibiotic treatment resulted in good clinical outcome. This case illustrates the use of molecular diagnostics to detect uncommon organisms in suspected prosthetic infections.

  11. Prosthesis use in adult acquired major upper-limb amputees: patterns of wear, prosthetic skills and the actual use of prostheses in activities of daily life.

    Science.gov (United States)

    Østlie, Kristin; Lesjø, Ingrid Marie; Franklin, Rosemary Joy; Garfelt, Beate; Skjeldal, Ola Hunsbeth; Magnus, Per

    2012-11-01

    To describe patterns of prosthesis wear and perceived prosthetic usefulness in adult acquired upper-limb amputees (ULAs). To describe prosthetic skills in activities of daily life (ADL) and the actual use of prostheses in the performance of ADL tasks. To estimate the influence of prosthetic skills on actual prosthesis use and the influence of background factors on prosthetic skills and actual prosthesis use. Cross-sectional study analysing population-based questionnaire data (n = 224) and data from interviews and clinical testing in a referred/convenience sample of prosthesis-wearing ULAs (n = 50). Effects were analysed using linear regression. 80.8% wore prostheses. 90.3% reported their most worn prosthesis as useful. Prosthetic usefulness profiles varied with prosthetic type. Despite demonstrating good prosthetic skills, the amputees reported actual prosthesis use in only about half of the ADL tasks performed in everyday life. In unilateral amputees, increased actual use was associated with sufficient prosthetic training and with the use of myoelectric vs cosmetic prostheses, regardless of amputation level. Prosthetic skills did not affect actual prosthesis use. No background factors showed significant effect on prosthetic skills. Most major ULAs wear prostheses. Individualised prosthetic training and fitting of myoelectric rather than passive prostheses may increase actual prosthesis use in ADL.

  12. Welding and Joining of Titanium Aluminides

    Directory of Open Access Journals (Sweden)

    Jian Cao

    2014-06-01

    Full Text Available Welding and joining of titanium aluminides is the key to making them more attractive in industrial fields. The purpose of this review is to provide a comprehensive overview of recent progress in welding and joining of titanium aluminides, as well as to introduce current research and application. The possible methods available for titanium aluminides involve brazing, diffusion bonding, fusion welding, friction welding and reactive joining. Of the numerous methods, solid-state diffusion bonding and vacuum brazing have been most heavily investigated for producing reliable joints. The current state of understanding and development of every welding and joining method for titanium aluminides is addressed respectively. The focus is on the fundamental understanding of microstructure characteristics and processing–microstructure–property relationships in the welding and joining of titanium aluminides to themselves and to other materials.

  13. Dynamic tracking of prosthetic valve motion and deformation from bi-plane x-ray views: feasibility study

    Science.gov (United States)

    Hatt, Charles R.; Wagner, Martin; Raval, Amish N.; Speidel, Michael A.

    2016-03-01

    Transcatheter aortic valve replacement (TAVR) requires navigation and deployment of a prosthetic valve within the aortic annulus under fluoroscopic guidance. To support improved device visualization in this procedure, this study investigates the feasibility of frame-by-frame 3D reconstruction of a moving and expanding prosthetic valve structure from simultaneous bi-plane x-ray views. In the proposed method, a dynamic 3D model of the valve is used in a 2D/3D registration framework to obtain a reconstruction of the valve. For each frame, valve model parameters describing position, orientation, expansion state, and deformation are iteratively adjusted until forward projections of the model match both bi-plane views. Simulated bi-plane imaging of a valve at different signal-difference-to-noise ratio (SDNR) levels was performed to test the approach. 20 image sequences with 50 frames of valve deployment were simulated at each SDNR. The simulation achieved a target registration error (TRE) of the estimated valve model of 0.93 +/- 2.6 mm (mean +/- S.D.) for the lowest SDNR of 2. For higher SDNRs (5 to 50) a TRE of 0.04 mm +/- 0.23 mm was achieved. A tabletop phantom study was then conducted using a TAVR valve. The dynamic 3D model was constructed from high resolution CT scans and a simple expansion model. TRE was 1.22 +/- 0.35 mm for expansion states varying from undeployed to fully deployed, and for moderate amounts of inter-frame motion. Results indicate that it is feasible to use bi-plane imaging to recover the 3D structure of deformable catheter devices.

  14. Analysis of titanium content in titanium tetrachloride solution

    Science.gov (United States)

    Bi, Xiaoguo; Dong, Yingnan; Li, Shanshan; Guan, Duojiao; Wang, Jianyu; Tang, Meiling

    2018-03-01

    Strontium titanate, barium titan and lead titanate are new type of functional ceramic materials with good prospect, and titanium tetrachloride is a commonly in the production such products. Which excellent electrochemical performance of ferroelectric tempreature coefficient effect.In this article, three methods are used to calibrate the samples of titanium tetrachloride solution by back titration method, replacement titration method and gravimetric analysis method. The results show that the back titration method has many good points, for example, relatively simple operation, easy to judgment the titration end point, better accuracy and precision of analytical results, the relative standard deviation not less than 0.2%. So, it is the ideal of conventional analysis methods in the mass production.

  15. Ultrasonic effects on titanium tanning of leather.

    Science.gov (United States)

    Peng, Biyu; Shi, Bi; Sun, Danhong; Chen, Yaowen; Shelly, Dennis C

    2007-03-01

    The effects of ultrasound on titanium tanning of leather were investigated. Either 20 or 40 kHz ultrasound was applied to the titanium tanning of pigskins. Five different treatment conditions were carried out and the effects were examined, such as leather shrinkage temperature (T(s)), titanium content and titanium distribution in the leather. Overall heat loading was carefully controlled. Results showed that 20 kHz ultrasound effectively improves titanium agent penetration into the hide and increases the leather's shrinkage temperature. Doubling the frequency to 40 kHz produced negligible enhancements. An impressive 105.6 degrees C T(s) was achieved using 20 kHz ultrasound pretreatment of the tanning liquor followed by 20 kHz ultrasound in the tanning mixture (liquor plus pigskins) in a special salt-free medium. Finally, using a unique ultrasonic tanning drum with 26.5 kHz ultrasound, the T(s) reached a record level of 106.5 degrees C, a value not achieved in conventional (no ultrasound) titanium tanning. The ultrasonic effects on titanium tanning of leather are judged to make a superior mineral tanned leather.

  16. Significance of angular mismatch between vertebral endplate and prosthetic endplate in lumbar total disc replacement.

    Science.gov (United States)

    Lee, Chong Suh; Chung, Sung Soo; Oh, Sung Kyun; You, Je Wook

    2011-05-01

    A retrospective study. To determine whether angular mismatch between the vertebral endplate and prosthetic endplate during lumbar total disc replacement (L-TDR) affects the radiological and clinical outcomes. A prosthesis anchored to the vertebral body by using a large central keel carries an inherent risk of angular mismatch between the vertebral endplate and prosthetic endplate at a segment with a greater degree of lordosis, such as L5-S1. Theoretically, this angular mismatch can cause several problems, such as segmental hyperlordosis, anterior positioning of the upper prosthesis, posterior prosthetic edge subsidence, decreased range of motion (ROM), and a poor clinical outcome. This study evaluated 64 prosthetic levels of 56 patients who were implanted with L-TDR between June 2002 and February 2006. There were 38 and 26 prosthetic levels at the L4-5 and L5-S1, respectively. The mean follow-up period was 25.6 (12 to 49) months. The angle of mismatch between the lower endplate of the upper vertebral body and the upper prosthetic plate, segmental flexion/extension ROM, segmental lordosis angle at extension, distance from the posterior wall of the vertebral body to the posterior prosthetic edge were measured by obtaining radiographs. Clinically, the Visual Analogue Scale and Oswestry Disability Index were also evaluated. The angular mismatches between the upper vertebra and prosthesis at L4-5 and L5-S1 were 1.6 degree and 5.6 degree, respectively (P body to the posterior edge of the prosthesis in L5-S1 were 6.8 degree (4 to 13), 12.8 degree (8 to 17), and 3.8 mm (1 to 6 mm) in patients with an angular mismatch of 0.05). Angular mismatch was more common in L5-S1 than in L4-5. L-TDR at the most lordotic level, L5-S1, and implantation of an upper prosthesis with a mismatched angle seem to be the causes of a reduced segmental ROM, increased segmental lordosis, and anterior malpositioning of the prosthesis. However, these changes do not affect the clinical outcomes of

  17. Differential contributions of specimen types, culturing, and 16S rRNA sequencing in diagnosis of prosthetic joint infections

    DEFF Research Database (Denmark)

    Larsen, Lone Heimann; Khalid, Vesal; Xu, Yijuan

    2018-01-01

    Prosthetic joint failure is mainly caused by infection, aseptic failure (AF), and mechanical problems. Infection detection has been improved with modified culture methods and molecular diagnostics. However, comparisons between modified and conventional microbiology methods are difficult due...... to variations in specimen sampling. In this prospective, multidisciplinary study of hip or knee prosthetic failures, we assessed the contributions of different specimen types, extended culture incubations, and 16S rRNA sequencing for diagnosing prosthetic joint infections (PJI). Project specimens included joint...... fluid (JF), bone biopsy specimens (BB), soft-tissue biopsy specimens (STB), and swabs (SW) from the prosthesis, collected in situ, and sonication fluid collected from prosthetic components (PC). Specimens were cultured for 6 (conventional) or 14 days, and 16S rRNA sequencing was performed at study...

  18. Diagnostic evaluation of left-sided prosthetic heart valve dysfunction

    NARCIS (Netherlands)

    Habets, Jesse; Budde, Ricardo P.; Symersky, Petr; van den Brink, Renee B.; de Mol, Bas A.; Mali, Willem P.; van Herwerden, Lex A.; Chamuleau, Steven A.

    Prosthetic heart valve (PHV) dysfunction is a rare, but potentially life-threatening, complication. In clinical practice, PHV dysfunction poses a diagnostic dilemma. Echocardiography and fluoroscopy are the imaging techniques of choice and are routinely used in daily practice. However, these

  19. Diagnostic evaluation of left-sided prosthetic heart valve dysfunction

    NARCIS (Netherlands)

    Habets, Jesse; Budde, Ricardo P.; Symersky, Petr; van den Brink, Renee B.; de Mol, Bas A.; Mali, Willem P.; van Herwerden, Lex A.; Chamuleau, Steven A.

    2011-01-01

    Prosthetic heart valve (PHV) dysfunction is a rare, but potentially life-threatening, complication. In clinical practice, PHV dysfunction poses a diagnostic dilemma. Echocardiography and fluoroscopy are the imaging techniques of choice and are routinely used in daily practice. However, these

  20. Prosthetic model, but not stiffness or height, affects the metabolic cost of running for athletes with unilateral transtibial amputations.

    Science.gov (United States)

    Beck, Owen N; Taboga, Paolo; Grabowski, Alena M

    2017-07-01

    Running-specific prostheses enable athletes with lower limb amputations to run by emulating the spring-like function of biological legs. Current prosthetic stiffness and height recommendations aim to mitigate kinematic asymmetries for athletes with unilateral transtibial amputations. However, it is unclear how different prosthetic configurations influence the biomechanics and metabolic cost of running. Consequently, we investigated how prosthetic model, stiffness, and height affect the biomechanics and metabolic cost of running. Ten athletes with unilateral transtibial amputations each performed 15 running trials at 2.5 or 3.0 m/s while we measured ground reaction forces and metabolic rates. Athletes ran using three different prosthetic models with five different stiffness category and height combinations per model. Use of an Ottobock 1E90 Sprinter prosthesis reduced metabolic cost by 4.3 and 3.4% compared with use of Freedom Innovations Catapult [fixed effect (β) = -0.177; P Run (β = -0.139; P = 0.002) prostheses, respectively. Neither prosthetic stiffness ( P ≥ 0.180) nor height ( P = 0.062) affected the metabolic cost of running. The metabolic cost of running was related to lower peak (β = 0.649; P = 0.001) and stance average (β = 0.772; P = 0.018) vertical ground reaction forces, prolonged ground contact times (β = -4.349; P = 0.012), and decreased leg stiffness (β = 0.071; P running. Instead, an optimal prosthetic model, which improves overall biomechanics, minimizes the metabolic cost of running for athletes with unilateral transtibial amputations. NEW & NOTEWORTHY The metabolic cost of running for athletes with unilateral transtibial amputations depends on prosthetic model and is associated with lower peak and stance average vertical ground reaction forces, longer contact times, and reduced leg stiffness. Metabolic cost is unrelated to prosthetic stiffness, height, and stride kinematic symmetry. Unlike nonamputees who decrease leg stiffness with

  1. Distal anastomotic vein adjunct usage in infrainguinal prosthetic bypasses.

    Science.gov (United States)

    McPhee, James T; Goodney, Philip P; Schanzer, Andres; Shaykevich, Shimon; Belkin, Michael; Menard, Matthew T

    2013-04-01

    Single-segment saphenous vein remains the optimal conduit for infrainguinal revascularization. In its absence, prosthetic conduit may be used. Existing data regarding the significance of anastomotic distal vein adjunct (DVA) usage with prosthetic grafts are based on small series. This is a retrospective cohort analysis derived from the regional Vascular Study Group of New England as well as the Brigham and Women's hospital database. A total of 1018 infrainguinal prosthetic bypass grafts were captured in the dataset from 73 surgeons at 15 participating institutions. Propensity scoring and 3:1 matching was performed to create similar exposure groups for analysis. Outcome measures of interest included: primary patency, freedom from major adverse limb events (MALEs), and amputation free survival at 1 year as a function of vein patch utilization. Time to event data were compared with the log-rank test; multivariable Cox proportional hazard models were used to evaluate the adjusted association between vein cuff usage and the primary end points. DVA was defined as a vein patch, cuff, or boot in any configuration. Of the 1018 bypass operations, 94 (9.2%) had a DVA whereas 924 (90.8%) did not (no DVA). After propensity score matching, 88 DVAs (25%) and 264 no DVAs (75%) were analyzed. On univariate analysis of the matched cohort, the DVA and no DVA groups were similar in terms of mean age (70.0 vs 69.0; P = .55), male sex (58.0% vs 58.3%; P > .99), and preoperative characteristics such as living at home (93.2% vs 94.3%; P = .79) and independent ambulatory status (72.7% vs 75.7%; P = .64). The DVA and no DVA groups had similar rates of major comorbidities such as hypertension chronic obstructive pulmonary disease, diabetes mellitus, coronary artery disease, and dialysis dependence (P > .05 for all). Likewise, they had similar rates of distal origin grafts (13.6% vs 12.5%; P = .85), critical limb ischemia indications (P = .53), and prior arterial bypass (58% vs 47%; P = .08

  2. Production of radioiodinated prosthetic group for indirect protein labeling

    International Nuclear Information System (INIS)

    Santos, Josefina da Silva

    2001-01-01

    Monoclonal antibodies and their fragments and, more recently, radiolabeled peptides have been extensively studied in order to develop radiopharmaceuticals for diagnostic and therapy in Nuclear Medicine. The radioiodination of proteins can be done by a direct method, with radioiodine being incorporated in to a tyrosine residue of the protein by electrophilic substitution. The main problem in the use of radioiodinated proteins, is that they are often dehalogenated in vivo by the action of specific enzymes, probably because of the structural similarity between iodophenyl groups and thyroid hormones. Several protein radioiodination methods have been developed in order to minimize this in vivo dehalogenation using prosthetic groups for indirect labeling. In this case, the radioiodine is first incorporated in to the prosthetic group that is subsequently attached to a terminal amino group or to a ε-amino group of lysine residue. The aim of this work is to obtain a radioiodinated prosthetic group for indirect labeling of proteins. The prosthetic group selected was the N-succinimidyl-4-radioiodine benzoate (SIB), obtained by the iodination of the p-bromobenzoic acid followed by the reaction with TSTU (0-(N-succinimidyl)-N,N,N',N'-tetramethyl uronium tetrafluoroborate) The results of these studies showed that the p-radio iodobenzoic acid was obtained with a radiochemical purity greater than 92% and a labeling yield of about 65%. Some reaction parameters were studied like temperature, time and Cu Cl mass (cataliser). The SIB was quantitatively obtained from p-radio iodobenzoic acid, using basic medium and after removing the water from the reaction using an nitrogen stream. The kinetic of this reaction is very fast with complete consumption of the p-radioiodebenzoic acid after 5 minutes. The coupling of the SIB prosthetic group to the protein was studied using Human Immunoglobulin (IgG) as a protein model. In a comparative way, the same protein was used on direct labeling

  3. Development and testing of new upper-limb prosthetic devices: research designs for usability testing.

    Science.gov (United States)

    Resnik, Linda

    2011-01-01

    The purposes of this article are to describe usability testing and introduce designs and methods of usability testing research as it relates to upper-limb prosthetics. This article defines usability, describes usability research, discusses research approaches to and designs for usability testing, and highlights a variety of methodological considerations, including sampling, sample size requirements, and usability metrics. Usability testing is compared with other types of study designs used in prosthetic research.

  4. Titanium nanostructures for biomedical applications

    Science.gov (United States)

    Kulkarni, M.; Mazare, A.; Gongadze, E.; Perutkova, Š.; Kralj-Iglič, V.; Milošev, I.; Schmuki, P.; Iglič, A.; Mozetič, M.

    2015-02-01

    Titanium and titanium alloys exhibit a unique combination of strength and biocompatibility, which enables their use in medical applications and accounts for their extensive use as implant materials in the last 50 years. Currently, a large amount of research is being carried out in order to determine the optimal surface topography for use in bioapplications, and thus the emphasis is on nanotechnology for biomedical applications. It was recently shown that titanium implants with rough surface topography and free energy increase osteoblast adhesion, maturation and subsequent bone formation. Furthermore, the adhesion of different cell lines to the surface of titanium implants is influenced by the surface characteristics of titanium; namely topography, charge distribution and chemistry. The present review article focuses on the specific nanotopography of titanium, i.e. titanium dioxide (TiO2) nanotubes, using a simple electrochemical anodisation method of the metallic substrate and other processes such as the hydrothermal or sol-gel template. One key advantage of using TiO2 nanotubes in cell interactions is based on the fact that TiO2 nanotube morphology is correlated with cell adhesion, spreading, growth and differentiation of mesenchymal stem cells, which were shown to be maximally induced on smaller diameter nanotubes (15 nm), but hindered on larger diameter (100 nm) tubes, leading to cell death and apoptosis. Research has supported the significance of nanotopography (TiO2 nanotube diameter) in cell adhesion and cell growth, and suggests that the mechanics of focal adhesion formation are similar among different cell types. As such, the present review will focus on perhaps the most spectacular and surprising one-dimensional structures and their unique biomedical applications for increased osseointegration, protein interaction and antibacterial properties.

  5. Titanium nanostructures for biomedical applications

    International Nuclear Information System (INIS)

    Kulkarni, M; Gongadze, E; Perutkova, Š; A Iglič; Mazare, A; Schmuki, P; Kralj-Iglič, V; Milošev, I; Mozetič, M

    2015-01-01

    Titanium and titanium alloys exhibit a unique combination of strength and biocompatibility, which enables their use in medical applications and accounts for their extensive use as implant materials in the last 50 years. Currently, a large amount of research is being carried out in order to determine the optimal surface topography for use in bioapplications, and thus the emphasis is on nanotechnology for biomedical applications. It was recently shown that titanium implants with rough surface topography and free energy increase osteoblast adhesion, maturation and subsequent bone formation. Furthermore, the adhesion of different cell lines to the surface of titanium implants is influenced by the surface characteristics of titanium; namely topography, charge distribution and chemistry. The present review article focuses on the specific nanotopography of titanium, i.e. titanium dioxide (TiO 2 ) nanotubes, using a simple electrochemical anodisation method of the metallic substrate and other processes such as the hydrothermal or sol-gel template. One key advantage of using TiO 2 nanotubes in cell interactions is based on the fact that TiO 2 nanotube morphology is correlated with cell adhesion, spreading, growth and differentiation of mesenchymal stem cells, which were shown to be maximally induced on smaller diameter nanotubes (15 nm), but hindered on larger diameter (100 nm) tubes, leading to cell death and apoptosis. Research has supported the significance of nanotopography (TiO 2 nanotube diameter) in cell adhesion and cell growth, and suggests that the mechanics of focal adhesion formation are similar among different cell types. As such, the present review will focus on perhaps the most spectacular and surprising one-dimensional structures and their unique biomedical applications for increased osseointegration, protein interaction and antibacterial properties. (topical review)

  6. Design, Sensing and Control of a Robotic Prosthetic Eye for Natural Eye Movement

    OpenAIRE

    J. J. Gu; M. Meng; A. Cook; P. X. Liu

    2006-01-01

    Loss of an eye is a tragedy for a person, who may suffer psychologically and physically. This paper is concerned with the design, sensing and control of a robotic prosthetic eye that moves horizontally in synchronization with the movement of the natural eye. Two generations of robotic prosthetic eye models have been developed. The first generation model uses an external infrared sensor array mounted on the frame of a pair of eyeglasses to detect the natural eye movement and to feed the contro...

  7. A new method for production of titanium vapor and synthesis of titanium nitride coatings

    Science.gov (United States)

    Grigoriev, Sergey N.; Melnik, Yury A.; Metel, Alexander S.; Volosova, Marina A.

    2018-03-01

    It is proposed to synthesize on machine parts and cutting tools wear-resistant titanium nitride coatings with the help of the hollow-cathode glow discharge, a molybdenum crucible for titanium evaporation being used as the anode of the discharge and a process vacuum chamber being used as the hollow cathode. The research revealed that at the anode surface area less than a critical value S* = (2m/M)1/2S, where S is the area of the chamber walls, m is the mass of electrons and M is the mass of ions, the anode fall of potential is positive and grows from ˜50 V at argon pressure p = 0.2 Pa to ˜2 kV at p = 0.02 Pa. At the discharge current I = 0.6 A electrons accelerated by the anode fall of 0.9 kV transport into the crucible with the inner diameter of 12 mm the power of ˜0.54 kW, which allows the titanium evaporation and the coating deposition rate of 5 µm·h-1 on a substrate distanced from the crucible at 100 mm. After the argon is replaced with the nitrogen, titanium nitride coating without titanium droplets is synthesized the deposition rate amounting to about the same value.

  8. Appcelerator Titanium patterns and best practices

    CERN Document Server

    Pollentine, Boydlee

    2013-01-01

    The book takes a step-by-step approach to help you understand CommonJS and Titanium architecture patterns, with easy to follow samples and plenty of in-depth explanations If you're an existing Titanium developer or perhaps a new developer looking to start off your Titanium applications "the right way", then this book is for you. With easy to follow examples and a full step-by-step account of architecting a sample application using CommonJS and MVC, along with chapters on new features such as ACS, you'll be implementing enterprise grade Titanium solutions in no time. You should have some JavaSc

  9. Structure and properties of Titanium for dental implants

    Directory of Open Access Journals (Sweden)

    M. Greger

    2009-10-01

    Full Text Available This paper describes manufacture of nano-structural titanium, its structure and properties. Nano-titanium has higher specific strength properties than ordinary (coarse-grained titanium. Nano-titanium was produced by the equal-channel angular pressing (ETAP process. The research it self was focused on physical base of strengthening and softening processes and developments occurring at the grain boundaries during the ECAP process at half-hot temperature. Strength of nano-titanium varies around 960 MPa, grain size around 300 nm.

  10. Tensile strength and impact resistance properties of materials used in prosthetic check sockets, copolymer sockets, and definitive laminated sockets

    OpenAIRE

    Maria J. Gerschutz, PhD; Michael L. Haynes, MS; Derek M. Nixon, BS; James M. Colvin, MS

    2011-01-01

    Prosthetic sockets serve as the interface between people with amputations and their prostheses. Although most materials used to make prosthetic sockets have been used for many years, knowledge of these materials' properties is limited, especially after they are subjected to fabrication processes. This study evaluated tensile and impact properties of the current state-of-the-art materials used to fabricate prosthetic check sockets, copolymer sockets, and definitive laminated sockets. Thermolyn...

  11. Research and Development on Titanium Alloys

    Science.gov (United States)

    1949-10-31

    information concerning the runs made * * In order to check the general operation of the train and furnace, a number of qualitative runs were made. These runs... General Technique. * . . * * . 109 The Analysis of Titanium . . . . ... ... 112 Notes and Comments, . . . .. . .. . . . 113 The Results from Vacuum...described in this report are as follows: 1. Arc ielting Titanium-Base Alloys. 2. Evaluation of Experimental Titanium-Base Alloys. 3. Investigation of

  12. Biomechanical characteristics, patient preference and activity level with different prosthetic feet: a randomized double blind trial with laboratory and community testing.

    Science.gov (United States)

    Raschke, Silvia U; Orendurff, Michael S; Mattie, Johanne L; Kenyon, David E A; Jones, O Yvette; Moe, David; Winder, Lorne; Wong, Angie S; Moreno-Hernández, Ana; Highsmith, M Jason; J Sanderson, David; Kobayashi, Toshiki

    2015-01-02

    Providing appropriate prosthetic feet to those with limb loss is a complex and subjective process influenced by professional judgment and payer guidelines. This study used a small load cell (Europa™) at the base of the socket to measure the sagittal moments during walking with three objective categories of prosthetic feet in eleven individuals with transtibial limb loss with MFCL K2, K3 and K4 functional levels. Forefoot stiffness and hysteresis characteristics defined the three foot categories: Stiff, Intermediate, and Compliant. Prosthetic feet were randomly assigned and blinded from participants and investigators. After laboratory testing, participants completed one week community wear tests followed by a modified prosthetics evaluation questionnaire to determine if a specific category of prosthetic feet was preferred. The Compliant category of prosthetic feet was preferred by the participants (P=0.025) over the Stiff and Intermediate prosthetic feet, and the Compliant and Intermediate feet had 15% lower maximum sagittal moments during walking in the laboratory (P=0.0011) compared to the Stiff feet. The activity level of the participants did not change significantly with any of the wear tests in the community, suggesting that each foot was evaluated over a similar number of steps, but did not inherently increase activity. This is the first randomized double blind study in which prosthetic users have expressed a preference for a specific biomechanical characteristic of prosthetic feet: those with lower peak sagittal moments were preferred, and specifically preferred on slopes, stairs, uneven terrain, and during turns and maneuvering during real world use. Copyright © 2014 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. Titanium oxide fever

    International Nuclear Information System (INIS)

    De Jonge, D.; Visser, J.

    2012-01-01

    One measure to improve air quality is to apply photo-catalytic substances that capture NOx onto the road surface or onto baffle boards alongside the roads. The effect of titanium oxide containing clinkers with coating was discussed in the report 'Demonstration project of air-purifying pavement in Hengelo, The Netherlands' that was published in May 2011. This article examines the way in which the effectiveness of this study was determined. Can titanium oxide containing clinkers and coatings indeed capture NOx?. [nl

  14. Telemedicine consulting in the patient preparation and planning of prosthetic tooth replacement.

    Science.gov (United States)

    Mladenović, Dragan; Tosić, Goran; Zivković, Dusan; Djindjić, Natasa; Mladenović, Lidija; Mladenović, Sanja; Marković, Ivana

    2013-09-01

    In the management of edentulous spaces, there is a permanent need of a dentist-prosthetician in charge to consult other specialists. Modern telemedicine, based on powerful computer and telecomunication systems, offers an adequate answer to these challenges, being able to transfer and obtain clinical data and consultation information over large distances. Using smartphone or a computer, the teleconsultant acces the system, downloads and review the data and photographs and gave suggestions. The system then enables direct, real time contact with the consultant, chat, or directs them to contact each other by phone. We presented telemedicine consulting in the patient preparation and planning of prosthetic tooth replacement in 3 cases with different teleconsultation requirements: the first case for prosthetic rehabilitation of his upper teeth, the second one for prosthetic management of his partial edentulousness and "a growth on his gums" in the vestibular region of the frontal teeth and the third one for prosthetic management of total edentulousness of her upper jaw. We used the system of telemedicine in dentistry, established at the Faculty of Medicine in Kosovska Mitrovica. The operation was based on the computer application system XPA3 Online, computer networking and mobile smartphone network. All consultations were succefull with no need for further procedures in regional center. The use of a mobile smartphone has brought about the mobility and availability of teleconsultant specialists in an extent never seen before. Prostheticians are thus able to offer better service to their patients and improve the quality of management of partially or totally edentulous patients, especially in rural areas.

  15. Surface EMG and intra-socket force measurement to control a prosthetic device

    Science.gov (United States)

    Sanford, Joe; Patterson, Rita; Popa, Dan

    2015-06-01

    Surface electromyography (SEMG) has been shown to be a robust and reliable interaction method allowing for basic control of powered prosthetic devices. Research has shown a marked decrease in EMG-classification efficiency throughout activities of daily life due to socket shift and movement and fatigue as well as changes in degree of fit of the socket throughout the subject's lifetime. Users with the most severe levels of amputation require the most complex devices with the greatest number of degrees of freedom. Controlling complex dexterous devices with limited available inputs requires the addition of sensing and interaction modalities. However, the larger the amputation severity, the fewer viable SEMG sites are available as control inputs. Previous work reported the use of intra-socket pressure, as measured during wrist flexion and extension, and has shown that it is possible to control a powered prosthetic device with pressure sensors. In this paper, we present data correlations of SEMG data with intra-socket pressure data. Surface EMG sensors and force sensors were housed within a simulated prosthetic cuff fit to a healthy-limbed subject. EMG and intra-socket force data was collected from inside the cuff as a subject performed pre-defined grip motions with their dominant hand. Data fusion algorithms were explored and allowed a subject to use both intra-socket pressure and SEMG data as control inputs for a powered prosthetic device. This additional input modality allows for an improvement in input classification as well as information regarding socket fit through out activities of daily life.

  16. Peri-prosthetic fractures around tumor endoprostheses: a retrospective analysis of eighteen cases.

    Science.gov (United States)

    Barut, Nicolas; Anract, Philippe; Babinet, Antoine; Biau, David

    2015-09-01

    Tumour hip and knee endoprostheses have become the mainstay for reconstruction of patients with bone tumours. Fixation into host bone has improved over time. However, some patients present with a peri-prosthetic fracture over follow-up. The objective of this study was to analyse the mode of presentation and survival of implant after a peri-prosthetic fracture around a tumour endoprosthesis. Eighteen peri-prosthetic fractures (17 patients) were included. All patients were treated at a tertiary care center. There were 11 (65%) women; the median age at the time of fracture was 38 years old. All implants were cemented and all knee endoprostheses were fixed-hinge. Twelve (67%) fractures occurred after femoral resection and six (33%) fractures after proximal tibial resection. There were three femoral neck fractures (UCS C), three femoral shaft type C fractures, two femoral shaft type B1, one tibial shaft type B2, three tibial shaft type C, three ankle fractures (UCS C) and three patella fractures (UCS F). Two fractures were treated conservatively and 16 were operated on. Only one patient had the implant revised. There were eight (44%) failures over follow-up; none of the conservative treatment failed. The cumulative probability of failure for any reason was 27% (8-52) and 55% (22-79) at five and ten years, respectively. Peri-prosthetic fractures around massive endoprostheses are different from that of standard implants. There are more type C fractures; internal fixation is an attractive option at the time of presentation but the risk of revision over follow-up is high and patients should be informed accordingly.

  17. Rapid prototyping prosthetic hand acting by a low-cost shape-memory-alloy actuator.

    Science.gov (United States)

    Soriano-Heras, Enrique; Blaya-Haro, Fernando; Molino, Carlos; de Agustín Del Burgo, José María

    2018-06-01

    The purpose of this article is to develop a new concept of modular and operative prosthetic hand based on rapid prototyping and a novel shape-memory-alloy (SMA) actuator, thus minimizing the manufacturing costs. An underactuated mechanism was needed for the design of the prosthesis to use only one input source. Taking into account the state of the art, an underactuated mechanism prosthetic hand was chosen so as to implement the modifications required for including the external SMA actuator. A modular design of a new prosthesis was developed which incorporated a novel SMA actuator for the index finger movement. The primary objective of the prosthesis is achieved, obtaining a modular and functional low-cost prosthesis based on additive manufacturing executed by a novel SMA actuator. The external SMA actuator provides a modular system which allows implementing it in different systems. This paper combines rapid prototyping and a novel SMA actuator to develop a new concept of modular and operative low-cost prosthetic hand.

  18. Comparative study of radiography and scintigraphy for loosening and infection of prosthetic hip replacement

    Energy Technology Data Exchange (ETDEWEB)

    Park, Mi Sook; Lee, Sun Wha; Choi, Woo Suk; Lim, Joo Won; Song, Han Joon; Ahn, Chi Yul [College of Medicine, Kyung Hee University, Seoul (Korea, Republic of)

    1987-10-15

    Prosthetic hip replacement is associated with certain complications which result in a painful hip. Many of these, e. g. prosthetic dislocation, fracture, trochanteric avulsion, and heterotopic calcification are easily diagnosed by conventional radiography. However, radiographic evaluation for infection and/pr loosening of prosthesis as major complications requiring reoperation often contributes little to the resolution of the diagnostic problem. The authors made a comparative study of plain radiography and scintigraphy of 39 cases performed revision at Kyung Hee University Hospital from Sep. '81-to Aug. '86. The results were as follows: 1. In 39 revised prosthetic hip replacement, 26 cases (67%) of loosening without infection and 11 cases (28%) of infection were proven. 2. In loosening of prosthesis, plain radiography showed true positive rate of 76% and true negative rate of 60%, and scintigraphy showed true positive rate of 75% and true negative rate of 95%. 3. In infection of prosthesis, plain radiography revealed true positive rate of 55% and true negative rate of 96%, and scintigraphy revealed true positive rate of 100% and true negative rate of 83%. 4. Scintigraphy and plain radiography were useful as complementary procedure in evaluating and differentiating loosening and/or infection of prosthetic component.

  19. Illusory movement perception improves motor control for prosthetic hands

    Science.gov (United States)

    Marasco, Paul D.; Hebert, Jacqueline S.; Sensinger, Jon W.; Shell, Courtney E.; Schofield, Jonathon S.; Thumser, Zachary C.; Nataraj, Raviraj; Beckler, Dylan T.; Dawson, Michael R.; Blustein, Dan H.; Gill, Satinder; Mensh, Brett D.; Granja-Vazquez, Rafael; Newcomb, Madeline D.; Carey, Jason P.; Orzell, Beth M.

    2018-01-01

    To effortlessly complete an intentional movement, the brain needs feedback from the body regarding the movement’s progress. This largely non-conscious kinesthetic sense helps the brain to learn relationships between motor commands and outcomes to correct movement errors. Prosthetic systems for restoring function have predominantly focused on controlling motorized joint movement. Without the kinesthetic sense, however, these devices do not become intuitively controllable. Here we report a method for endowing human amputees with a kinesthetic perception of dexterous robotic hands. Vibrating the muscles used for prosthetic control via a neural-machine interface produced the illusory perception of complex grip movements. Within minutes, three amputees integrated this kinesthetic feedback and improved movement control. Combining intent, kinesthesia, and vision instilled participants with a sense of agency over the robotic movements. This feedback approach for closed-loop control opens a pathway to seamless integration of minds and machines. PMID:29540617

  20. Customized mold radiotherapy with prosthetic apparatus for oral cancers

    International Nuclear Information System (INIS)

    Noguchi, Tadahide; Tsuchiya, Yoshiyuki; Hayasaka, Junichi; Itoh, Hiroto; Jinbu, Yoshinori; Kusama, Mikio; Takahashi, Satoru; Nakazawa, Masanori

    2014-01-01

    Eight patients (6 males, 2 females; median age, 78 years; age range, 31-94 years) were treated by mold radiotherapy with a prosthetic apparatus for oral cancers between October 2006 and March 2013. The primary sites were the tongue in 3 cases, hard palate and buccal mucosa in 2 cases each, and oral floor in 1 case. The type of treatment consisted of radical radiotherapy and palliative radiotherapy in 2 cases each, and preoperative radiotherapy, postoperative radiotherapy, additional radiotherapy after external beam radiotherapy and systemic chemotherapy in 1 case each. Patients received 40-50 Gy in 8-10 fractions with mold radiotherapy. Two patients who received radical radiotherapy showed no signs of recurrence or metastasis. The present therapy contributed to patients' palliative, postoperative, and preoperative therapy. Mold radiotherapy with a prosthetic appliance was performed safely and was a useful treatment for several types of oral cancer. (author)

  1. Red flag in the emergency department: fracture and primary failure of a prosthetic valve.

    Science.gov (United States)

    Ozsarac, Murat; Karcioglu, Ozgur; Ayrik, Cuneyt; Bozkurt, Seyran; Turkcuer, Ibrahim; Gumrukcu, Serhat

    2005-07-01

    This case report concerns a patient with fracture and primary dysfunction of a prosthetic valve. A 40-year-old man presented to the Emergency Department with a chief complaint of breakthrough pleuritic back pain and shortness of breath. Past surgical history was significant only for an aortic valve replacement and mitral valve replacement performed 16 years prior. The transthoracic echocardiography raised suspicion of prosthesis malposition. The patient was taken to the operating room by cardiothoracic surgeons for valve replacement. Operative findings revealed that a prosthetic valve leaflet in the mitral position had broken off. Primary prosthetic valve failure should not be overlooked in the differential diagnosis of patients with valve replacement and a rapidly deteriorating clinical course. Emergency echocardiography is a guide to convenient diagnosis and management. Early surgical consultation and early reparative surgery might prevent unnecessary morbidity and mortality.

  2. Developing and modeling of voice control system for prosthetic robot arm in medical systems

    Directory of Open Access Journals (Sweden)

    Koksal Gundogdu

    2018-04-01

    Full Text Available In parallel with the development of technology, various control methods are also developed. Voice control system is one of these control methods. In this study, an effective modelling upon mathematical models used in the literature is performed, and a voice control system is developed in order to control prosthetic robot arms. The developed control system has been applied on four-jointed RRRR robot arm. Implementation tests were performed on the designed system. As a result of the tests; it has been observed that the technique utilized in our system achieves about 11% more efficient voice recognition than currently used techniques in the literature. With the improved mathematical modelling, it has been shown that voice commands could be effectively used for controlling the prosthetic robot arm. Keywords: Voice recognition model, Voice control, Prosthetic robot arm, Robotic control, Forward kinematic

  3. Formation of titanium diboride coatings during the anodic polarization of titanium in a chloride melt with a low boron oxide content

    Science.gov (United States)

    Elshina, L. A.; Malkov, V. B.; Molchanova, N. G.

    2015-02-01

    The corrosion-electrochemical behavior of titanium in a molten eutectic mixture of cesium and sodium chlorides containing up to 1 wt % boron oxide is studied in the temperature range 810-870 K in an argon atmosphere. The potential, the current, and the rate of titanium corrosion are determined. The optimum conditions of forming a dense continuous titanium diboride coating on titanium with high adhesion to the metallic base are found for the anodic activation of titanium in the molten electrolyte under study.

  4. Dynamic Facial Prosthetics for Sufferers of Facial Paralysis

    Directory of Open Access Journals (Sweden)

    Fergal Coulter

    2011-10-01

    Full Text Available BackgroundThis paper discusses the various methods and the materialsfor the fabrication of active artificial facial muscles. Theprimary use for these will be the reanimation of paralysedor atrophied muscles in sufferers of non-recoverableunilateral facial paralysis.MethodThe prosthetic solution described in this paper is based onsensing muscle motion of the contralateral healthy musclesand replicating that motion across a patient’s paralysed sideof the face, via solid state and thin film actuators. Thedevelopment of this facial prosthetic device focused onrecreating a varying intensity smile, with emphasis ontiming, displacement and the appearance of the wrinklesand folds that commonly appear around the nose and eyesduring the expression.An animatronic face was constructed with actuations beingmade to a silicone representation musculature, usingmultiple shape-memory alloy cascades. Alongside theartificial muscle physical prototype, a facial expressionrecognition software system was constructed. This formsthe basis of an automated calibration and reconfigurationsystem for the artificial muscles following implantation, soas to suit the implantee’s unique physiognomy.ResultsAn animatronic model face with silicone musculature wasdesigned and built to evaluate the performance of ShapeMemory Alloy artificial muscles, their power controlcircuitry and software control systems. A dual facial motionsensing system was designed to allow real time control overmodel – a piezoresistive flex sensor to measure physicalmotion, and a computer vision system to evaluate real toartificial muscle performance.Analysis of various facial expressions in real subjects wasmade, which give useful data upon which to base thesystems parameter limits.ConclusionThe system performed well, and the various strengths andshortcomings of the materials and methods are reviewedand considered for the next research phase, when newpolymer based artificial muscles are constructed

  5. Ureaplasma parvum prosthetic joint infection detected by PCR.

    Science.gov (United States)

    Farrell, John J; Larson, Joshua A; Akeson, Jeffrey W; Lowery, Kristin S; Rounds, Megan A; Sampath, Rangarajan; Bonomo, Robert A; Patel, Robin

    2014-06-01

    We describe the first reported case of Ureaplasma parvum prosthetic joint infection (PJI) detected by PCR. Ureaplasma species do not possess a cell wall and are usually associated with colonization and infection of mucosal surfaces (not prosthetic material). U. parvum is a relatively new species name for certain serovars of Ureaplasma urealyticum, and PCR is useful for species determination. Our patient presented with late infection of his right total knee arthroplasty. Intraoperative fluid and tissue cultures and pre- and postoperative synovial fluid cultures were all negative. To discern the pathogen, we employed PCR coupled with electrospray ionization mass spectrometry (PCR/ESI-MS). Our patient's failure to respond to empirical antimicrobial treatment and our previous experience with PCR/ESI-MS in culture-negative cases of infection prompted us to use this approach over other diagnostic modalities. PCR/ESI-MS detected U. parvum in all samples. U. parvum-specific PCR testing was performed on all synovial fluid samples to confirm the U. parvum detection. Copyright © 2014, American Society for Microbiology. All Rights Reserved.

  6. Creating nanoshell on the surface of titanium hydride bead

    Directory of Open Access Journals (Sweden)

    PAVLENKO Vyacheslav Ivanovich

    2016-12-01

    Full Text Available The article presents data on the modification of titanium hydride bead by creating titanium nanoshell on its surface by ion-plasma vacuum magnetron sputtering. To apply titanium nanoshell on the titanium hydride bead vacuum coating plant of multifunctional nanocomposite coatings QVADRA 500 located in the center of high technology was used. Analysis of the micrographs of the original surface of titanium hydride bead showed that the microstructure of the surface is flat, smooth, in addition the analysis of the microstructure of material surface showed the presence of small porosity, roughness, mainly cavities, as well as shallow longitudinal cracks. The presence of oxide film in titanium hydride prevents the free release of hydrogen and fills some micro-cracks on the surface. Differential thermal analysis of both samples was conducted to determine the thermal stability of the initial titanium hydride bead and bead with applied titanium nanoshell. Hydrogen thermal desorption spectra of the samples of the initial titanium hydride bead and bead with applied titanium nanoshell show different thermal stability of compared materials in the temperature range from 550 to 860о C. Titanium nanoshells applied in this way allows increasing the heat resistance of titanium hydride bead – the temperature of starting decomposition is 695о C and temperature when decomposition finishes is more than 1000о C. Modified in this way titanium hydride bead can be used as a filler in the radiation protective materials used in the construction or upgrading biological protection of nuclear power plants.

  7. A Prosthetic Foot Emulator to Optimize Prescription of Prosthetic Feet in Veterans and Service Members with Leg Amputations

    Science.gov (United States)

    2017-09-01

    mobility, prosthetic foot preference and walking ability after two weeks of use in the home and community setting. No exclusions based on sex , race...2012 Page 17 of 33 Data collection Photos and video recording With the participant’s explicit consent, we may take video and photos during portions of...this study, for documentation and use in research publications. All videos and photos will exclue the participant’s face and identifying marks will

  8. Three-dimensional flow structures past a bio-prosthetic valve in an in-vitro model of the aortic root

    OpenAIRE

    Hasler, David; Obrist, Dominik

    2018-01-01

    The flow field past a prosthetic aortic valve comprises many details that indicate whether the prosthesis is functioning well or not. It is, however, not yet fully understood how an optimal flow scenario would look, i.e. which subtleties of the fluid dynamics in place are essential regarding the durability and compatibility of a prosthetic valve. In this study, we measured and analyzed the 3D flow field in the vicinity of a bio-prosthetic heart valve in function of the aortic root size. The m...

  9. Current standard rules of combined anteversion prevent prosthetic impingement but ignore osseous contact in total hip arthroplasty.

    Science.gov (United States)

    Weber, Markus; Woerner, Michael; Craiovan, Benjamin; Voellner, Florian; Worlicek, Michael; Springorum, Hans-Robert; Grifka, Joachim; Renkawitz, Tobias

    2016-12-01

    In this prospective study of 135 patients undergoing cementless total hip arthroplasty (THA) we asked whether six current definitions of combined anteversion prevent impingement and increase postoperative patient individual impingement-free range-of-motion (ROM). Implant position was measured by an independent, external institute on 3D-CT performed six weeks post-operatively. Post-operative ROM was calculated using a CT-based algorithm detecting osseous and/or prosthetic impingement by virtual hip movement. Additionally, clinical ROM was evaluated pre-operatively and one-year post-operatively by a blinded observer. Combined component position of cup and stem according to the definitions of Ranawat, Widmer, Dorr, Hisatome and Yoshimine inhibited prosthetic impingement in over 90 %, while combined osseous and prosthetic impingement still occurred in over 40 % of the cases. The recommendations by Jolles, Widmer, Dorr, Yoshimine and Hisatome enabled higher flexion (p ≤ 0.001) and internal rotation (p ≤ 0.006). Clinically, anteversion rules of Widmer and Yoshimine provided one-year post-operatively statistically but not clinically relevant higher internal rotation (p ≤0.034). Standard rules of combined anteversion detect prosthetic but fail to prevent combined osseous and prosthetic impingement in THA. Future models will have to account for the patient-individual anatomic situation to ensure impingement-free ROM.

  10. Oral health-related quality of life and prosthetic status of nursing home residents with or without dementia.

    Science.gov (United States)

    Klotz, Anna-Luisa; Hassel, Alexander Jochen; Schröder, Johannes; Rammelsberg, Peter; Zenthöfer, Andreas

    2017-01-01

    The objective of this cross-sectional study was to evaluate the effect of prosthetic status on the oral health-related quality of life (OHRQoL) of nursing home residents with or without dementia. The study was performed in 14 nursing homes across the federal state of Baden-Württemberg, Germany. All eligible participants were included, and general and medical information and information about their dental and prosthetic statuses were collected. The Geriatric Oral Health Assessment Index (GOHAI) was administered to evaluate OHRQoL. The Mini-Mental State Examination (MMSE) served to classify participants into living or not living with dementia according to the established cutoff value for dementia (MMSE health was also similar in both groups ( P >0.05). The number of teeth (odds ratio [OR]: 2.0), the type of prosthetic status (OR: 6.5), and denture-related treatment needs (OR: 2.4) were the major factors significantly affecting OHRQoL ( P nursing home residents is substantially compromised. Several prosthetic treatment needs for residents living with or without dementia were identified. Edentulism without tooth replacement and having <5 teeth resulted in an increased risk of substantially compromised OHRQoL. Further studies should be conducted to determine whether improvements in prosthetic status can increase OHRQoL.

  11. Titanium electroplating of copper in molten salt media

    International Nuclear Information System (INIS)

    Renaud, Denis

    1985-01-01

    After a bibliographical survey on electroplating in molten salt media and on the electrolytic production of titanium, the author explains the reasons for the choice of the LiF-NaF-KF eutectic mix as solvent. He recalls the main properties which are used, and describes the conventional and convolutional processing of data obtained by linear volt-amperometry. He presents the electrolyte preparation mode which takes into account the existence of titanium ions with intermediate oxidation degree, and the reactivity of titanium with oxygenated species. Experimental results are discussed. Then, after the study of the mechanism of reduction of trivalent titanium into titanium on molybdenum (intermetallic diffusion is here negligible), he reports the study of this mechanism on copper (it is a more complicated situation, due to combinations between titanium and copper). The effect of different parameters (electrolyte purity, current density, electrode potential and temperature) is interpreted in order to identify optimal conditions for titanium electroplating of copper [fr

  12. Laser shock peening of titanium 6-4 alloy

    International Nuclear Information System (INIS)

    Brar, N.S.; Hopkins, A.; Laber, M.W.

    2000-01-01

    Laser shock peening of titanium 6-4 has been shown to improve its high cycle fatigue life. Residual compressive stresses generated on the surface of titanium 6-4, as a result of laser shocking, have shown dramatic improvement in the performance of aircraft turbine blades. Laser shocking of titanium was carried out with a 20 ns pulse width, 50 joule pulsed laser, operated by LSP Technologies, Columbus, OH. Titanium disks, 20-mm in diameter, and ranging in thicknesses from zero (bare LiF) to 3-mm were subjected to laser shock to monitor amplitude and temporal stress profiles of the pulsed laser. Laser shock stress amplitudes on the back of titanium disks were monitored with VISAR using LiF as the window material. The peak shock stress produced in LiF (titanium thickness zero) was measured to be 16±1 GPa. The laser shock amplitude decays to about 2.7 GPa while propagating through 3-mm thick disk of titanium 6-4

  13. Strength and structure of nanocrystalline titanium

    International Nuclear Information System (INIS)

    Noskova, N.I.; Pereturina, I.A.; Elkina, O.A.; Stolyarov, V.V.

    2004-01-01

    Investigation results on strength and plasticity of nanocrystalline titanium VT-1 are presented. Specific features of plastic deformation on tension of this material specimens in an electron microscope column are studied in situ. It is shown that nanocrystalline titanium strength and plasticity at room temperature are dependent on the structure and nanograin size. It is revealed that deformation processes in nanocrystalline titanium are characterized by activation of deformation rotational modes and microtwinning [ru

  14. Rapid prototyped porous nickel–titanium scaffolds as bone substitutes

    Directory of Open Access Journals (Sweden)

    Waldemar Hoffmann

    2014-06-01

    Full Text Available While calcium phosphate–based ceramics are currently the most widely used materials in bone repair, they generally lack tensile strength for initial load bearing. Bulk titanium is the gold standard of metallic implant materials, but does not match the mechanical properties of the surrounding bone, potentially leading to problems of fixation and bone resorption. As an alternative, nickel–titanium alloys possess a unique combination of mechanical properties including a relatively low elastic modulus, pseudoelasticity, and high damping capacity, matching the properties of bone better than any other metallic material. With the ultimate goal of fabricating porous implants for spinal, orthopedic and dental applications, nickel–titanium substrates were fabricated by means of selective laser melting. The response of human mesenchymal stromal cells to the nickel–titanium substrates was compared to mesenchymal stromal cells cultured on clinically used titanium. Selective laser melted titanium as well as surface-treated nickel–titanium and titanium served as controls. Mesenchymal stromal cells had similar proliferation rates when cultured on selective laser melted nickel–titanium, clinically used titanium, or controls. Osteogenic differentiation was similar for mesenchymal stromal cells cultured on the selected materials, as indicated by similar gene expression levels of bone sialoprotein and osteocalcin. Mesenchymal stromal cells seeded and cultured on porous three-dimensional selective laser melted nickel–titanium scaffolds homogeneously colonized the scaffold, and following osteogenic induction, filled the scaffold’s pore volume with extracellular matrix. The combination of bone-related mechanical properties of selective laser melted nickel–titanium with its cytocompatibility and support of osteogenic differentiation of mesenchymal stromal cells highlights its potential as a superior bone substitute as compared to clinically used

  15. Swing Phase Control of Semi-Active Prosthetic Knee Using Neural Network Predictive Control With Particle Swarm Optimization.

    Science.gov (United States)

    Ekkachai, Kittipong; Nilkhamhang, Itthisek

    2016-11-01

    In recent years, intelligent prosthetic knees have been developed that enable amputees to walk as normally as possible when compared to healthy subjects. Although semi-active prosthetic knees utilizing magnetorheological (MR) dampers offer several advantages, they lack the ability to generate active force that is required during some states of a normal gait cycle. This prevents semi-active knees from achieving the same level of performance as active devices. In this work, a new control algorithm for a semi-active prosthetic knee during the swing phase is proposed to reduce this gap. The controller uses neural network predictive control and particle swarm optimization to calculate suitable command signals. Simulation results using a double pendulum model show that the generated knee trajectory of the proposed controller is more similar to the normal gait than previous open-loop controllers at various ambulation speeds. Moreover, the investigation shows that the algorithm can be calculated in real time by an embedded system, allowing for easy implementation on real prosthetic knees.

  16. Corynebacterium minutissimum vascular graft infection: case report and review of 281 cases of prosthetic device-related Corynebacterium infection.

    Science.gov (United States)

    Reece, Rebecca M; Cunha, Cheston B; Rich, Josiah D

    2014-09-01

    Corynebacterium spp. have proven their pathogenic potential in causing infections, particularly in the setting of immunosuppression and prosthetic devices. We conducted a PubMed literature review of all cases of Corynebacterium prosthetic device infections published in the English language through December 2013. The majority of cases involved peritoneal dialysis and central venous catheters, but prosthetic joints and central nervous system shunts/drains were also involved. The management of these cases in terms of retention or removal of the device was not uniform; however, the overall mortality remained the same among both groups. All of these prosthetic device infections pose potential problems in management when the device cannot be removed safely for the patient, especially with the lack of data on the pathogenicity of Corynebacterium species. However with better identification of species and sensitivities, successful treatment is possible even with retention of the device.

  17. Role of CT in patients with prosthetic heart valves

    NARCIS (Netherlands)

    Suchá, D.

    2016-01-01

    Valvular heart disease accounts for a substantial part of the cardiovascular disease worldwide with an estimated prevalence of 2.5% in the Western population aged <65 years and over 13% in the population aged >75 years. Surgical prosthetic heart valve (PHV) replacement is the indicated therapy for

  18. Diagnostic flowcharts in osteomyelitis, spondylodiscitis and prosthetic joint infection

    NARCIS (Netherlands)

    Jutte, P.; Lazzeri, E.; Sconfienza, L. M.; Cassar-Pullicino, V.; Trampuz, A.; Petrosillo, N.; Signore, A.

    Infections of the bone, spine and prosthetic joints are serious and complex conditions to diagnose and to treat. Structured diagnostic workup may very well improve the accuracy and speed of diagnosis, thereby improving the outcome since treatment may very well be more successful and less harmful if

  19. A rare case of prosthetic endocarditis and dehiscence in a mechanical valved conduit.

    Science.gov (United States)

    Kannan, Arun; Smith, Cristy; Subramanian, Sreekumar; Janardhanan, Rajesh

    2014-02-07

    A middle-aged adult patient with a history of aortic root replacement with a mechanical valved conduit and remote chest trauma was referred to our institution with prosthetic endocarditis. Transoesophageal echocardiogram at our institution confirmed a near-complete dehiscence of the prosthetic aortic valve from the conduit, with significant perivalvular flow forming a pseudoaneurysm. The patient underwent a high-risk re-operation, involving redo aortic root replacement with a homograft after extensive debridement of the infected tissue. The patient was discharged to an outside facility after an uncomplicated hospital course, and remains stable.

  20. Mechanical properties and fracture of titanium hydrides

    International Nuclear Information System (INIS)

    Koketsu, Hideyuki; Taniyama, Yoshihiro; Yonezu, Akio; Cho, Hideo; Ogawa, Takeshi; Takemoto, Mikio; Nakayama, Gen

    2006-01-01

    Titanium hydrides tend to suffer fracture when their thicknesses reach a critical thickness. Morphology and mechanical property of the hydrides are, however, not well known. The study aims to reveal the hydride morphology and fracture types of the hydrides. Chevron shaped plate hydrides were found to be produced on the surface of pure titanium (Grade 1) and Grade 7 titanium absorbing hydrogen. There were tree types of fracture of the hydrides, i.e., crack in hydride layer, exfoliation of the layer and shear-type fracture of the hydride plates, during the growth of the hydrides and deformation. We next estimated the true stress-strain curves of the hydrides on Grade 1 and 7 titanium using the dual Vickers indentation method, and the critical strain causing the Mode-I fine crack by indentation. Fracture strength and strain of the hydrides in Grade 1 titanium were estimated as 566 MPa and 4.5%, respectively. Those of the hydride in Grade 7 titanium were 498 MPa and 16%. Though the fracture strains estimated from the plastic instability of true stress-strain curves were approximately the half of those estimated by finite element method, the titanium hydrides were estimated to possess some extent of toughness or plastic deformation capability. (author)

  1. Locomotor Performance During Rehabilitation of People With Lower Limb Amputation and Prosthetic Nonuse 12 Months After Discharge.

    Science.gov (United States)

    Roffman, Caroline E; Buchanan, John; Allison, Garry T

    2016-07-01

    It is recognized that multifactorial assessments are needed to evaluate balance and locomotor function in people with lower limb amputation. There is no consensus on whether a single screening tool could be used to identify future issues with locomotion or prosthetic use. The purpose of this study was to determine whether different tests of locomotor performance during rehabilitation were associated with significantly greater risk of prosthetic abandonment at 12 months postdischarge. This was a retrospective cohort study. Data for descriptive variables and locomotor tests (ie, 10-Meter Walk Test [10MWT], Timed "Up & Go" Test [TUGT], Six-Minute Walk Test [6MWT], and Four Square Step Test [FSST]) were abstracted from the medical records of 201 consecutive participants with lower limb amputation. Participants were interviewed and classified as prosthetic users or nonusers at 12 months postdischarge. The Mann-Whitney U test was used to analyze whether there were differences in locomotor performance. Receiver operating characteristic curves were generated to determine performance thresholds, and relative risk (RR) was calculated for nonuse. At 12 months postdischarge, 18% (n=36) of the participants had become prosthetic nonusers. Performance thresholds, area under the curve (AUC), and RR of nonuse (95% confidence intervals [CI]) were: for the 10MWT, if walking speed was ≤0.44 ms(-1) (AUC=0.743), RR of nonuse=2.76 (95% CI=1.83, 3.79; PLocomotor performance during rehabilitation may predict future risk of prosthetic nonuse. It may be implied that the 10MWT has the greatest clinical utility as a single screening tool for prosthetic nonuse, given the highest proportion of participants were able to perform this test early in rehabilitation. However, as locomotor skills improve, other tests (in particular, the 6MWT) have specific clinical utility. To fully enable implementation of these locomotor criteria for prosthetic nonuse into clinical practice, validation is warranted

  2. The Effects of Uniquely-Processed Titanium on Biological Systems: Implications for Human Health and Performance

    Directory of Open Access Journals (Sweden)

    David S. Rowlands

    2014-01-01

    Full Text Available Titanium is biocompatible and widely utilized in a variety of applications. Recently, titanium in pico-nanometer scale and soluble form (Aqua Titan has expanded its use to applied human health and performance. The purpose of this article is to review the current evidence associated with specific physiological responses to Aqua Titan-treated materials. In vitro studies have shown that application of Aqua Titan can modify membrane potential and long-term potentiation in isolated hippocampal neurons, suggesting reduced pain memory as a possible mechanism for reported analgesia. Proximal contact with Aqua Titan-treated titanium increased gene expression, protein synthesis, cell growth and adhesion in normal cultured muscle and bone cells, suggesting application for Aqua Titan in clinical implant procedures and wound healing. Evidence for beneficial effects on neuromuscular control of muscle-tendon function and improvements in running economy in human athletes was seen when Aqua Titan-treated tape was applied to the human triceps surae following fatigue induced by prior strenuous exercise. Finally, behavioral responses and effects on the autonomic nervous system to environmental exposure suggest Aqua Titan may promote a mild relaxant, or stress-suppressive response. Together, data suggest exposure to Aqua Titan-treated materials modulates aspects of growth and function in neuronal and other musculoskeletal cells with possible benefits to musculotendinous recovery from exercise and to the systemic response to stress.

  3. Telemedicine consulting in the patient preparation and planning of prosthetic tooth replacement

    Directory of Open Access Journals (Sweden)

    Mladenović Dragan

    2013-01-01

    Full Text Available Introduction. In the management of edentulous spaces, there is a permanent need of a dentist-prosthetician in charge to consult other specialists. Modern telemedicine, based on powerful computer and telecomunication systems, offers an adequate answer to these challenges, being able to transfer and obtain clinical data and consultation information over large distances. Using smartphone or a computer, the teleconsultant acces the system, downloads and review the data and photographs and gave suggestions. The system then enables direct, real time contact with the consultant, chat, or directs them to contact each other by phone. Case report. We presented telemedicine consulting in the patient preparation and planning of prosthetic tooth replacement in 3 cases with different teleconsultation requirements: the first case for prosthetic rehabilitation of his upper teeth, the second one for prosthetic management of his partial edentulousness and “a growth on his gums” in the vestibular region of the frontal teeth and the third one for prosthetic management of total edentulousness of her upper jaw. We used the system of telemedicine in dentistry, established at the Faculty of Medicine in Kosovska Mitrovica. The operation was based on the computer application system XPA3 Online, computer networking and mobile smartphone network. All consultations were succefull with no need for further procedures in regional center. Conclusion. The use of a mobile smartphone has brought about the mobility and availability of teleconsultant specialists in an extent never seen before. Prostheticians are thus able to offer better service to their patients and improve the quality of management of partially or totally edentulous patients, especially in rural areas.

  4. Automated hexahedral mesh generation from biomedical image data: applications in limb prosthetics.

    Science.gov (United States)

    Zachariah, S G; Sanders, J E; Turkiyyah, G M

    1996-06-01

    A general method to generate hexahedral meshes for finite element analysis of residual limbs and similar biomedical geometries is presented. The method utilizes skeleton-based subdivision of cross-sectional domains to produce simple subdomains in which structured meshes are easily generated. Application to a below-knee residual limb and external prosthetic socket is described. The residual limb was modeled as consisting of bones, soft tissue, and skin. The prosthetic socket model comprised a socket wall with an inner liner. The geometries of these structures were defined using axial cross-sectional contour data from X-ray computed tomography, optical scanning, and mechanical surface digitization. A tubular surface representation, using B-splines to define the directrix and generator, is shown to be convenient for definition of the structure geometries. Conversion of cross-sectional data to the compact tubular surface representation is direct, and the analytical representation simplifies geometric querying and numerical optimization within the mesh generation algorithms. The element meshes remain geometrically accurate since boundary nodes are constrained to lie on the tubular surfaces. Several element meshes of increasing mesh density were generated for two residual limbs and prosthetic sockets. Convergence testing demonstrated that approximately 19 elements are required along a circumference of the residual limb surface for a simple linear elastic model. A model with the fibula absent compared with the same geometry with the fibula present showed differences suggesting higher distal stresses in the absence of the fibula. Automated hexahedral mesh generation algorithms for sliced data represent an advancement in prosthetic stress analysis since they allow rapid modeling of any given residual limb and optimization of mesh parameters.

  5. Histopathological and Immunohistochemical Evaluation of Pannus Tissue in Patients with Prosthetic Valve Dysfunction.

    Science.gov (United States)

    Karakoyun, Süleyman; Ozan Gürsoy, Mustafa; Yesin, Mahmut; Kalçık, Macit; Astarcıoğlu, Mehmet Ali; Gündüz, Sabahattin; Emrah Oğuz, Ali; Çoban Kökten, Şermin; Nimet Karadayı, Ayşe; Tuncer, Altuğ; Köksal, Cengiz; Gökdeniz, Tayyar; Özkan, Mehmet

    2016-01-01

    Prosthetic valve dysfunction due to pannus formation is a rare but serious complication. Currently, limited data are available concerning the pathogenesis and immunohistochemical properties of pannus. The study aim was to investigate the morphological, histopathological and immunohistochemical characteristics of pannus formation in patients with prosthetic valve dysfunction. A total of 35 patients (10 males, 25 females; mean age 44 ± 16 years) who had undergone re-do valve surgery due to prosthetic valve obstruction was enrolled in the study. Immunohistochemical studies were aimed at evaluating the expression of alphasmooth muscle actin (α-SMA) and desmin in myofibroblasts and smooth muscle cells; epithelial membrane antigen (EMA) in epithelial cells; and CD34, Factor VIII and vascular endothelial growth factor (VEGF) in endothelial cells. Matrix metalloproteinases (MMPs) -2 and -9, and transforming growth factor-beta (TGF-β) were used to demonstrate cytokine release from macrophages, leukocytes, fibroblasts and myofibroblasts. Pannus appeared as a tough and thick tissue hyperplasia which began from outside the suture ring in the periannular region and extended to the inflow and outflow surfaces of the prosthetic valves. Histopathological analysis showed the pannus tissue to consist of chronic inflammatory cells (lymphocytes, plasma cells, macrophages and foreign body giant cells), spindle cells such as myofibroblasts, capillary blood vessels and endothelial cells laying down the lumens. Calcification was present in the pannus tissue of 19 explanted prostheses. Immunohistochemical studies revealed positive α-SMA expression in all patients, whereas 60.5% of patients were positive for desmin, 50% for EMA, 42.1% for VEGF, 39.5% for TBF-β, 42.1% for MMP-2, 86.8% for CD34, and 97.4% for Factor VIII. MMP-9 was negative in all patients. Pannus tissue appears to be formed as the result of a neointimal response in periannular regions of prosthetic valves that consist

  6. EFFICIENCY OF PROSTHETIC TREATMENT WITH POST RESECTION PROSTHESES WITH SOLID SUBSTITUTE PART

    Directory of Open Access Journals (Sweden)

    Ivan Gerdzhikov

    2016-08-01

    Full Text Available Aim: The aim of this study is to track the effectiveness of prosthetic treatment with post resection dentures with solid substitute part and their role in the restoration of damaged functions. Materials and methods: The study included 14 patients (9 men and 5 women with different size and location of defects in the upper jaw treated in the period 2010-2016 with post resection prostheses with a solid substitute part. The impressions were taken with irreversible hydrocolloid impression material. The prostheses were completed by heat-curing acrylic with low quantity residual monomer. The effectiveness of prosthetics was evaluated by the method of Mihaylov for both oral-nasal examination of the pressure with the device "Oronasopneumotest." For objectifying and assess the occlusal-articulation ratios was held computerized occlusal analysis with the system T-SCAN 8. Results: The results showed successful obturation and sealing of defects in all patients. It was found satisfactory recovery of the speaking function and normalization of occlusal-articulation ratios. Conclusion: The prosthetic treatment with post resection prostheses with a solid substitute part allows successful recovery of the lost speech and chewing functions, helping to restore self esteem and social rehabilitation of patients.

  7. Computed Tomography of the complications of prosthetic surgery of the abdominal aorta

    International Nuclear Information System (INIS)

    Giovagnorio, Francesco; Andreoli, Chiara; De Cicco, Maria Luisa

    1997-01-01

    Computerized Tomography has gained an important role in the diagnosis of the complications of prosthetic surgery of the abdominal aorta: the importance of such complications come from their frequency, which is proportional to the increasing number of interventions, and their severity. The authors investigated the CT patterns of the most frequent complications. 24 patients referred for strongly suspected postoperative complications were examined in 2 years: fever and leukocytosis (20 cases) and progressive anemia (4 cases) were the most frequent findings. The operation had been performed 7± 12 weeks before (2 patients were excluded because surgery dated less than 3 weeks. 14 patients had infective complications: thickening (57%) and inhomogeneity (43%) of the periprosthetic wrap and ectopic gas bubble (78%) were the most frequent Computerized Tomography findings. The authors also observed 2 periprosthetic hematomas, 1 aneurysm relapse and 1 prosthetic graft rupture. In conclusion, CT confirmed its important role in the study of the complications of prosthetic aortic surgery, despite its know poor specificity in the demonstration of the aorta in the first 2-3 months postoperatively, in the initial stages of infection and in the diagnosis of aorta-enteric fistulas

  8. Kinetic study of synthesis of Titanium carbide by methano thermal reduction of Titanium dioxide

    International Nuclear Information System (INIS)

    Alizadeh, R.; Ostrovski, O.

    2011-01-01

    Reduction of the Titanium dioxide, TiO 2 , by methane was investigated in this work. The thermodynamic of reaction was examined and found favorable. The reaction of titanium dioxide with methane was carried out in the temperature range 1150 d egree C to 1450 d egree C at atmospheric pressure with industrial high porosity pellets prepared from titanium dioxide powder. The evolved gas analyzing method was used for determination of the extent of reduction rate. The gas products of the reaction are mostly CO and trace amount of CO 2 and H 2 O. The synthesized product powder was characterized by X-ray diffraction for elucidating solid phase compositions. The effect of varying temperature was studied during the reduction. The conversion-time data have been interpreted by using the grain model. For first order reaction with respect to methane concentration, the activation energy of titanium dioxide reduction by methane is found to be 51.4 kcal/g mole. No detailed investigation of kinetic and mechanism of the reaction was reported in literatures.

  9. Prosthetic graft infection: limitations of indium white blood cell scanning

    International Nuclear Information System (INIS)

    Brunner, M.C.; Mitchell, R.S.; Baldwin, J.C.; James, D.R.; Olcott, C. IV; Mehigan, J.T.; McDougall, I.R.; Miller, D.C.

    1986-01-01

    The lack of a rapid, noninvasive, and accurate method to confirm or rule out prosthetic graft infection continues to constitute a compelling and vexing clinical problem. A host of adjunctive diagnostic techniques has been used in the past, but early promising results subsequently have usually not yielded acceptable sensitivity (reflecting false negatives) and specificity (reflecting false positive) data. White blood cell (WBC) indium 111 scanning has recently been added to this list. The utility and accuracy of 111 In WBC scans were assessed by retrospective review of WBC scan results in 70 patients undergoing evaluation for possible prosthetic graft infection over a 7-year period. Operative and autopsy data (mean follow-up, 18 months for survivors with negative scans) were used to confirm the 22 positive, 45 negative, and three equivocal WBC scans. The false positive rate (+/- 70% confidence limits) was 36% +/- 6% (n = 8) among the 22 patients with positive scans (44% +/- 6% [11 of 25] if the three equivocal scans are included as false positive), yielding a specificity of 85% +/- 5% and an overall accuracy rate of 88% +/- 4% (80% +/- 5% and 84% +/- 5%, respectively, if the three equivocal cases are considered as false positive). All three patients with equivocal scans ultimately were judged not to have prosthetic graft infection. As implied by the high accuracy rate, the sensitivity of the test was absolute (100% [14 of 14]); there were no false negative results

  10. Comparison of using different bridge prosthetic designs for partial defect restoration through mathematical modeling.

    Science.gov (United States)

    Styranivska, Oksana; Kliuchkovska, Nataliia; Mykyyevych, Nataliya

    2017-01-01

    To analyze the stress-strain states of bone and abutment teeth during the use of different prosthetic designs of fixed partial dentures with the use of relevant mathematical modeling principles. The use of Comsol Multiphysics 3.5 (Comsol AB, Sweden) software during the mathematical modeling of stress-strain states provided numerical data for analytical interpretation in three different clinical scenarios with fixed dentures and different abutment teeth and demountable prosthetic denture with the saddle-shaped intermediate part. Microsoft Excel Software (Microsoft Office 2017) helped to evaluate absolute mistakes of stress and strain parameters of each abutment tooth during three modeled scenarios and normal condition and to summarize data into the forms of tables. In comparison with the fixed prosthetic denture supported by the canine, first premolar, and third molar, stresses at the same abutment teeth with the use of demountable denture with the saddle-shaped intermediate part decreased: at the mesial abutment tooth by 2.8 times, at distal crown by 6.1 times, and at the intermediate part by 11.1 times, respectively, the deformation level decreased by 3.1, 1.9, and 1.4 times at each area. The methods of mathematical modeling proved that complications during the use of fixed partial dentures based on the overload effect of the abutment teeth and caused by the deformation process inside the intermediate section of prosthetic construction.

  11. In situ formation of titanium carbide using titanium and carbon-nanotube powders by laser cladding

    International Nuclear Information System (INIS)

    Savalani, M.M.; Ng, C.C.; Li, Q.H.; Man, H.C.

    2012-01-01

    Titanium metal matrix composite coatings are considered to be important candidates for high wear resistance applications. In this study, TiC reinforced Ti matrix composite layers were fabricated by laser cladding with 5, 10, 15 and 20 wt% carbon-nanotube. The effects of the carbon-nanotube content on phase composition, microstructure, micro-hardness and dry sliding wear resistance of the coating were studied. Microstructural observation using scanning electron microscopy showed that the coatings consisted of a matrix of alpha-titanium phases and the reinforcement phase of titanium carbide in the form of fine dendrites, indicating that titanium carbide was synthesized by the in situ reaction during laser irradiation. Additionally, measurements on the micro-hardness and dry sliding wear resistance of the coatings indicated that the mechanical properties were affected by the amount of carbon-nanotube in the starting precursor materials and were enhanced by increasing the carbon-nanotube content. Results indicated that the composite layers exhibit high hardness and excellent wear resistance.

  12. In situ formation of titanium carbide using titanium and carbon-nanotube powders by laser cladding

    Energy Technology Data Exchange (ETDEWEB)

    Savalani, M.M., E-mail: mmfsmm@inet.polyu.edu.hk [Department of Industrial and Systems Engineering, Hong Kong Polytechnic University (Hong Kong); Ng, C.C.; Li, Q.H.; Man, H.C. [Department of Industrial and Systems Engineering, Hong Kong Polytechnic University (Hong Kong)

    2012-01-15

    Titanium metal matrix composite coatings are considered to be important candidates for high wear resistance applications. In this study, TiC reinforced Ti matrix composite layers were fabricated by laser cladding with 5, 10, 15 and 20 wt% carbon-nanotube. The effects of the carbon-nanotube content on phase composition, microstructure, micro-hardness and dry sliding wear resistance of the coating were studied. Microstructural observation using scanning electron microscopy showed that the coatings consisted of a matrix of alpha-titanium phases and the reinforcement phase of titanium carbide in the form of fine dendrites, indicating that titanium carbide was synthesized by the in situ reaction during laser irradiation. Additionally, measurements on the micro-hardness and dry sliding wear resistance of the coatings indicated that the mechanical properties were affected by the amount of carbon-nanotube in the starting precursor materials and were enhanced by increasing the carbon-nanotube content. Results indicated that the composite layers exhibit high hardness and excellent wear resistance.

  13. Determining asymmetry of roll-over shapes in prosthetic walking

    NARCIS (Netherlands)

    Curtze, C.; Otten, Bert; Hof, A.L.; Postema, K.

    2011-01-01

    How does the inherent asymmetry of the locomotor system in people with lower-limb amputation affect the ankle-foot roll-over shape of prosthetic walking? In a single-case design, we evaluated the walking patterns of six people with lower-limb amputation (3 transtibial and 3 transfemoral) and three

  14. Fiber-array based optogenetic prosthetic system for stimulation therapy

    Science.gov (United States)

    Gu, Ling; Cote, Chris; Tejeda, Hector; Mohanty, Samarendra

    2012-02-01

    Recent advent of optogenetics has enabled activation of genetically-targeted neuronal cells using low intensity blue light with high temporal precision. Since blue light is attenuated rapidly due to scattering and absorption in neural tissue, optogenetic treatment of neurological disorders may require stimulation of specific cell types in multiple regions of the brain. Further, restoration of certain neural functions (vision, and auditory etc) requires accurate spatio-temporal stimulation patterns rather than just precise temporal stimulation. In order to activate multiple regions of the central nervous system in 3D, here, we report development of an optogenetic prosthetic comprising of array of fibers coupled to independently-controllable LEDs. This design avoids direct contact of LEDs with the brain tissue and thus does not require electrical and heat isolation, which can non-specifically stimulate and damage the local brain regions. The intensity, frequency, and duty cycle of light pulses from each fiber in the array was controlled independently using an inhouse developed LabView based program interfaced with a microcontroller driving the individual LEDs. While the temporal profile of the light pulses was controlled by varying the current driving the LED, the beam profile emanating from each fiber tip could be sculpted by microfabrication of the fiber tip. The fiber array was used to stimulate neurons, expressing channelrhodopsin-2, in different locations within the brain or retina. Control of neural activity in the mice cortex, using the fiber-array based prosthetic, is evaluated from recordings made with multi-electrode array (MEA). We also report construction of a μLED array based prosthetic for spatio-temporal stimulation of cortex.

  15. Prosthetic component segmentation with blur compensation: a fast method for 3D fluoroscopy.

    Science.gov (United States)

    Tarroni, Giacomo; Tersi, Luca; Corsi, Cristiana; Stagni, Rita

    2012-06-01

    A new method for prosthetic component segmentation from fluoroscopic images is presented. The hybrid approach we propose combines diffusion filtering, region growing and level-set techniques without exploiting any a priori knowledge of the analyzed geometry. The method was evaluated on a synthetic dataset including 270 images of knee and hip prosthesis merged to real fluoroscopic data simulating different conditions of blurring and illumination gradient. The performance of the method was assessed by comparing estimated contours to references using different metrics. Results showed that the segmentation procedure is fast, accurate, independent on the operator as well as on the specific geometrical characteristics of the prosthetic component, and able to compensate for amount of blurring and illumination gradient. Importantly, the method allows a strong reduction of required user interaction time when compared to traditional segmentation techniques. Its effectiveness and robustness in different image conditions, together with simplicity and fast implementation, make this prosthetic component segmentation procedure promising and suitable for multiple clinical applications including assessment of in vivo joint kinematics in a variety of cases.

  16. May one-stage exchange for Candida albicans peri-prosthetic infection be successful?

    Science.gov (United States)

    Jenny, J-Y; Goukodadja, O; Boeri, C; Gaudias, J

    2016-02-01

    Fungal infection of a total joint arthroplasty has a low incidence but is generally considered as more difficult to cure than bacterial infection. As for bacterial infection, two-stage exchange is considered as the gold standard of treatment. We report two cases of one-stage total joint exchange for fungal peri-prosthetic infection with Candida albicans, where the responsible pathogens was only identified on intraoperative samples. This situation can be considered as a one-stage exchange for fungal peri-prosthetic infection without preoperative identification of the responsible organism, which is considered as having a poor prognosis. Both cases were free of infection after two years. One-stage revision has several potential advantages over two-stage revision, including shorter hospital stay and rehabilitation, no interim period with significant functional impairment, shorter antibiotic treatment, better functional outcome and probably lower costs. We suggest that one-stage revision for C. albicans peri-prosthetic infection may be successful even without preoperative fungal identification. Level IV-Historical cases. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  17. Experimental Technique of Titanium Fire in Aero-engine

    Directory of Open Access Journals (Sweden)

    MI Guangbao

    2016-06-01

    Full Text Available Titanium fire is the typical catastrophic fault in the aero-engine. Aiming at the urgent demand for experimental technique of titanium fire from advanced high thrust-weight ratio aero-engine, the combustion technology and theory of titanium alloy based on friction oxygen concentration method (FOC were systematically studied. The evaluation method of fireproof property and the friction ignition model were built, and the fireproof mechanism was illustrated. By generalizing recent progress in experimental technique of titanium fire from three levels, including evolutionary rule, mechanism and prevention and control technology, the ideas and directions of experimental technique associated with the application research of titanium fire in the future were proposed, namely overall evaluation of fireproof property close to air flow environment of the aero-engine, prediction model of fireproof property and experimental verification of fireproof technique under the air flow environment of aero-engine. It is necessary to establish the prevention system of titanium fire in aero-engine, which contributes to the realization of "full titanium" in compressor and to the increase of high thrust-weight ratio.

  18. Early prosthetic valve endocarditis caused by Corynebacterium kroppenstedtii.

    Science.gov (United States)

    Hagemann, Jürgen Benjamin; Essig, Andreas; Herrmann, Manuel; Liebold, Andreas; Quader, Mohamed Abo

    2015-12-01

    Corynebacterium (C.) kroppenstedtii is a rarely detected agent of bacterial infections in humans. Here, we describe the first case of prosthetic valve endocarditis caused by C. kroppenstedtii. Application of molecular methods using surgically excised valve tissue was a cornerstone for the establishment of the microbiological diagnosis, which is crucial for targeted antimicrobial treatment. Copyright © 2015 Elsevier GmbH. All rights reserved.

  19. Relationship between surface properties (roughness, wettability) of titanium and titanium alloys and cell behaviour

    International Nuclear Information System (INIS)

    Ponsonnet, L.; Reybier, K.; Jaffrezic, N.; Comte, V.; Lagneau, C.; Lissac, M.; Martelet, C.

    2003-01-01

    Cell attachment and spreading to titanium-based alloy surfaces is a major parameter in implant technology. In this paper, substratum surface hydrophobicity, surface free energy, interfacial free energy and surface roughness were investigated to ascertain which of these parameters is predominant in human fibroblast spreading. Two methods for contact angle measurement were compared: the sessile drop method and the captive bubble two-probe method. The relationship between surface roughness and the sessile drop contact angles of various engineered titanium surfaces such as commercial pure titanium (cp-Ti), titanium-aluminium-vanadium alloy (Ti-6Al-4V), and titanium-nickel (NiTi), was shown. Surface free energy (SFE) calculations were performed from contact angles obtained on smooth samples based on the same alloys in order to eliminate the roughness effect. SFE of the surfaces have been calculated using the Owens-Wendt (OW) and Van Oss (VO) approaches with the sessile drop method. The OW calculations are used to obtain the dispersive (γ d ) and polar (γ p ) component of SFE, and the VO approach allows to reach the apolar (γ LW ) and the polar acid-base component (γ ab ) of the surface. From captive bubble contact angle experiments (air or octane bubble under water), the interfacial free energy of the different surfaces in water was obtained. A relationship between cell spreading and the polar component of SFE was found. Interfacial free energy values were low for all the investigated surfaces indicating good biocompatibility for such alloys

  20. Autologous alternative veins may not provide better outcomes than prosthetic conduits for below-knee bypass when great saphenous vein is unavailable.

    Science.gov (United States)

    Avgerinos, Efthymios D; Sachdev, Ulka; Naddaf, Abdallah; Doucet, Dannielle R; Mohapatra, Abhisekh; Leers, Steven A; Chaer, Rabih A; Makaroun, Michel S

    2015-08-01

    There is a need to better define the role of alternative autologous vein (AAV) segments over contemporary prosthetic conduits in patients with critical limb ischemia when great saphenous vein (GSV) is not available for use as the bypass conduit. Consecutive patients who underwent bypass to infrageniculate targets between 2007 and 2011 were categorized in three groups: GSV, AAV, and prosthetic. The primary outcome was graft patency. The secondary outcome was limb salvage. Cox proportional hazards regression was used to adjust for baseline confounding variables. A total of 407 infrainguinal bypasses to below-knee targets were analyzed; 255 patients (63%) received a single-segment GSV, 106 patients (26%) received an AAV, and 46 patients (11%) received a prosthetic conduit. Baseline characteristics were similar among groups, with the exception of popliteal targets and anticoagulation use being more frequent in the prosthetic group. Primary patency at 2 and 5 years was estimated at 47% and 32%, respectively, for the GSV group; 24% and 23% for the AAV group; and 43% and 38% for the prosthetic group. Primary assisted patency at 2 and 5 years was estimated at 71% and 55%, respectively, for the GSV group; 53% and 51% for the AAV group; and 45% and 40% for the prosthetic group. Secondary patency at 2 and 5 years was estimated at 75% and 60%, respectively, for the GSV group; 57% and 55% for the AAV group; and 46% and 41% for the prosthetic group. In Cox analysis, primary patency (hazard ratio [HR], 0.55; P < .001; 95% confidence interval [CI], 0.404-0.758), primary assisted patency (HR, 0.57; P = .004; 95% CI, 0.388-0.831), and secondary patency (HR, 0.56; P = .005; 95% CI, 0.372-0.840) were predicted by GSV compared with AAV, but there was no difference between AAV and prosthetic grafts except for the primary patency, for which prosthetic was protective (HR, 0.38; P < .001; 95% CI, 0.224-0.629). Limb salvage was similar among groups. AAV conduits may not offer a significant

  1. Analogy and differences between aluminium and titanium electrowinning

    CSIR Research Space (South Africa)

    Van Vuuren, DS

    2006-09-01

    Full Text Available larger market. The authors have tested this route experimentally, but could not produce pure titanium. The failure of electrowinning pure, molten titanium has been interpreted in terms of the analogy and differences between aluminium and titanium...

  2. Acute Mitral Valve Dysfunction Due to Escape of Prosthetic Mechanical Leaflet and Peripheral Leaftlet Embolization.

    Science.gov (United States)

    Calik, Eyup Serhat; Limandal, Husnu Kamil; Arslan, Umit; Tort, Mehmet; Yildiz, Ziya; Bayram, Ednan; Dag, Ozgur; Kaygin, Mehmet Ali; Erkut, Bilgehan

    2015-12-14

    Leaflet escape of prosthetic valve is rare but potentially life threatening. Early diagnosis is essential on account of avoiding mortality, and emergency surgical correction is compulsory. This complication has previously been reported for both monoleaflet and bileaflet valve models. A 30-year-old man who had undergone mitral valve replacement with a bileaflet valve 8 years prior at another center was admitted with acute-onset with cardiogenic shock as an emergency case. Transthoracic echocardiograms showed acute-starting severe mitral regurgitation associated with prosthetic mitral valve. There was a suspicious finding of a single prosthetic mitral leaflet. But the problem related with the valve wasn't specifically determined. The patient underwent emergent surgery for replacement of the damaged prosthetic valves immediately. There was no tissue impingement and thrombosis, one of the two leaflets was absent, and there were no signs of endocarditis or pannus formation in the prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet during surgery. The damaged valve was removed and a replacement 29 mm bileaflet mechanical valve was inserted by right lateral thoracotomy. After post-operative week one, the abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the left femoral artery. Fifteen days after the surgery the escaped leaflet was removed safely from the left femoral artery and the patient made a complete recovery. The escaped leaflet showed a fracture of one of the pivot systems caused by structural failure. Early cardiac surgery should be applied because of life-threatening problems.

  3. Agreement between pre-operative and intra-operative bacteriological samples in 85 chronic peri-prosthetic infections.

    Science.gov (United States)

    Matter-Parrat, V; Ronde-Oustau, C; Boéri, C; Gaudias, J; Jenny, J-Y

    2017-04-01

    Whether pre-operative microbiological sampling contributes to the management of chronic peri-prosthetic infection remains controversial. We assessed agreement between the results of pre-operative and intra-operative samples in patients undergoing single-stage prosthesis exchange to treat chronic peri-prosthetic infection. Agreement between pre-operative and intra-operative samples exceeds 75% in patients undergoing single-stage exchange of a hip or knee prosthesis to treat chronic peri-prosthetic infection. This single-centre retrospective study included 85 single-stage prosthesis exchange procedures in 82 patients with chronic peri-prosthetic infection at the hip or knee. Agreement between pre-operative and intra-operative sample results was evaluated. Changes to the initial antibiotic regimen made based on the intra-operative sample results were recorded. Of 149 pre-operative samples, 109 yielded positive cultures, in 75/85 cases. Of 452 intra-operative samples, 354 yielded positive cultures, in 85/85 cases. Agreement was complete in 54 (63%) cases and partial in 9 (11%) cases; there was no agreement in the remaining 22 (26%) cases. The complete agreement rate was significantly lower than 75% (P=0.01). The initial antibiotic regimen was inadequate in a single case. Pre-operative sampling may contribute to the diagnosis of peri-prosthetic infection but is neither necessary nor sufficient to confirm the diagnosis and identify the causative agent. The spectrum of the initial antibiotic regimen cannot be safely narrowed based on the pre-operative sample results. We suggest the routine prescription of a probabilistic broad-spectrum antibiotic regimen immediately after the prosthesis exchange, even when a pathogen was identified before surgery. IV, retrospective study. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  4. Pre prosthetic reconstruction of alveolar ridge

    Directory of Open Access Journals (Sweden)

    Prabhuji Munivenkatappa Lakshmaiahenkatesh

    2011-01-01

    Full Text Available Dento-alveolar bony defects are common and occur due to a variety of causes, such as, pulpal pathology, traumatic tooth extraction, advanced periodontal disease, implant failure, tumor or congenital anomalies. These defects often cause a significant problem in dental treatment and rehabilitation. Many techniques exist for effective soft and hard tissue augmentation. The approach is largely based on the extent of the defect and specific procedures to be performed for the implant or prosthetic rehabilitation. This article presents case reports of soft and hard tissue ridge augmentation.

  5. Direct dynamic synthesis of nanodispersed phases of titanium oxides upon sputtering of electrodischarge titanium plasma into an air atmosphere

    Science.gov (United States)

    Sivkov, A. A.; Gerasimov, D. Yu.; Nikitin, D. S.

    2017-01-01

    Experimental investigations of the possibility of directly synthesizing nanodispersed crystalline phases of titanium dioxides with rutile and anatase structures in a hypervelocity jet of electroerosion plasma generated by a coaxial magnetoplasma accelerator with titanium electrodes are presented. A powder product containing nanosized polymorphic phases of titanium dioxide with a spherical shape of particles has been manufactured.

  6. Correctness of multi-detector-row computed tomography for diagnosing mechanical prosthetic heart valve disorders using operative findings as a gold standard

    Energy Technology Data Exchange (ETDEWEB)

    Tsai, I.Chen [Taichung Veterans General Hospital, Department of Radiology, Taichung (China); Institute of Clinical Medicine and Faculty of Medicine, National Yang-Ming University, Taipei (China); Lin, Yung-Kai; Chang, Yen; Wang, Chung-Chi; Hsieh, Shih-Rong; Wei, Hao-Ji; Tsai, Hung-Wen [Taichung Veterans General Hospital, Section of Cardiovascular Surgery, Cardiovascular Center, Taichung (China); Fu, Yun-Ching; Jan, Sheng-Ling [Institute of Clinical Medicine and Faculty of Medicine, National Yang-Ming University, Taipei (China); Taichung Veterans General Hospital, Section of Pediatric Cardiology, Department of Pediatrics, Taichung (China); Wang, Kuo-Yang [Taichung Veterans General Hospital, Section of General Cardiology, Cardiovascular Center, Taichung (China); Chung-Shan Medical University, Department of Medicine, Taichung (China); Chen, Min-Chi; Chen, Clayton Chi-Chang [Taichung Veterans General Hospital, Department of Radiology, Taichung (China); Central Taiwan University of Science and Technology, Department of Radiological Technology, Taichung (China)

    2009-04-15

    The purpose was to compare the findings of multi-detector computed tomography (MDCT) in prosthetic valve disorders using the operative findings as a gold standard. In a 3-year period, we prospectively enrolled 25 patients with 31 prosthetic heart valves. MDCT and transthoracic echocardiography (TTE) were done to evaluate pannus formation, prosthetic valve dysfunction, suture loosening (paravalvular leak) and pseudoaneurysm formation. Patients indicated for surgery received an operation within 1 week. The MDCT findings were compared with the operative findings. One patient with a Bjoerk-Shiley valve could not be evaluated by MDCT due to a severe beam-hardening artifact; thus, the exclusion rate for MDCT was 3.2% (1/31). Prosthetic valve disorders were suspected in 12 patients by either MDCT or TTE. Six patients received an operation that included three redo aortic valve replacements, two redo mitral replacements and one Amplatzer ductal occluder occlusion of a mitral paravalvular leak. The concordance of MDCT for diagnosing and localizing prosthetic valve disorders and the surgical findings was 100%. Except for images impaired by severe beam-hardening artifacts, MDCT provides excellent delineation of prosthetic valve disorders. (orig.)

  7. Titanium application to power plant condensers

    International Nuclear Information System (INIS)

    Itoh, H.

    1987-01-01

    Recently, the growth of operating performance and construction plan of titanium-tubed condensers in thermal and unclear power plants has been very impressive. High-quality, thinner welded titanium tubes used for cooling tubes, matching design specifications of condensers, have been stably supplied through mass production. It now can be said that various technical problems for titanium-tubed condensers have been solved, but data on operating performance in large-scale commercial plants are still scarce, and site-by-site information needs be exchanged more frequently and on a larger scale. Projects to replace existing condenser cooling tubes with those of corrosion-resistant titanium have been actively furthered, with the only remaining barrier to full employment being cost effectiveness. It is hoped that condenser and tube manufacturers will conduct more joint value analyses

  8. Stress corrosion cracking of titanium alloys

    Science.gov (United States)

    May, R. C.; Beck, F. H.; Fontana, M. G.

    1971-01-01

    Experiments were conducted to study (1) the basic electrochemical behavior of titanium in acid chloride solutions and (2) the response of the metal to dynamic straining in the same evironment. The aim of this group of experiments was to simulate, as nearly as possible, the actual conditions which exist at the tip of a crack. One of the foremost theories proposed to explain the propagation of stress corrosion cracks is a hydrogen embrittlement theory involving the precipitation of embrittling titanium hydrides inside the metal near the crack tip. An initial survey of the basic electrochemical literature indicated that surface hydrides play a critical role in the electrochemistry of titanium in acid solutions. A comprehensive analysis of the effect of surface films, particularly hydrides, on the electrochemical behavior of titanium in these solution is presented.

  9. Complications with computer-aided designed/computer-assisted manufactured titanium and soldered gold bars for mandibular implant-overdentures: short-term observations.

    Science.gov (United States)

    Katsoulis, Joannis; Wälchli, Julia; Kobel, Simone; Gholami, Hadi; Mericske-Stern, Regina

    2015-01-01

    Implant-overdentures supported by rigid bars provide stability in the edentulous atrophic mandible. However, fractures of solder joints and matrices, and loosening of screws and matrices were observed with soldered gold bars (G-bars). Computer-aided designed/computer-assisted manufactured (CAD/CAM) titanium bars (Ti-bars) may reduce technical complications due to enhanced material quality. To compare prosthetic-technical maintenance service of mandibular implant-overdentures supported by CAD/CAM Ti-bar and soldered G-bar. Edentulous patients were consecutively admitted for implant-prosthodontic treatment with a maxillary complete denture and a mandibular implant-overdenture connected to a rigid G-bar or Ti-bar. Maintenance service and problems with the implant-retention device complex and the prosthesis were recorded during minimally 3-4 years. Annual peri-implant crestal bone level changes (ΔBIC) were radiographically assessed. Data of 213 edentulous patients (mean age 68 ± 10 years), who had received a total of 477 tapered implants, were available. Ti-bar and G-bar comprised 101 and 112 patients with 231 and 246 implants, respectively. Ti-bar mostly exhibited distal bar extensions (96%) compared to 34% of G-bar (p overdentures supported by soldered gold bars or milled CAD/CAM Ti-bars are a successful treatment modality but require regular maintenance service. These short-term observations support the hypothesis that CAD/CAM Ti-bars reduce technical complications. Fracture location indicated that the titanium thickness around the screw-access hole should be increased. © 2013 Wiley Periodicals, Inc.

  10. Recurrent pannus formation causing prosthetic aortic valve dysfunction: is excision without valve re-replacement applicable?

    Science.gov (United States)

    Darwazah, Ahmad K

    2012-06-29

    Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function.The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement.A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve.Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function.

  11. A pulsatile flow model for in vitro quantitative evaluation of prosthetic valve regurgitation

    Directory of Open Access Journals (Sweden)

    S. Giuliatti

    2000-03-01

    Full Text Available A pulsatile pressure-flow model was developed for in vitro quantitative color Doppler flow mapping studies of valvular regurgitation. The flow through the system was generated by a piston which was driven by stepper motors controlled by a computer. The piston was connected to acrylic chambers designed to simulate "ventricular" and "atrial" heart chambers. Inside the "ventricular" chamber, a prosthetic heart valve was placed at the inflow connection with the "atrial" chamber while another prosthetic valve was positioned at the outflow connection with flexible tubes, elastic balloons and a reservoir arranged to mimic the peripheral circulation. The flow model was filled with a 0.25% corn starch/water suspension to improve Doppler imaging. A continuous flow pump transferred the liquid from the peripheral reservoir to another one connected to the "atrial" chamber. The dimensions of the flow model were designed to permit adequate imaging by Doppler echocardiography. Acoustic windows allowed placement of transducers distal and perpendicular to the valves, so that the ultrasound beam could be positioned parallel to the valvular flow. Strain-gauge and electromagnetic transducers were used for measurements of pressure and flow in different segments of the system. The flow model was also designed to fit different sizes and types of prosthetic valves. This pulsatile flow model was able to generate pressure and flow in the physiological human range, with independent adjustment of pulse duration and rate as well as of stroke volume. This model mimics flow profiles observed in patients with regurgitant prosthetic valves.

  12. Titanium Metal Powder Production by the Plasma Quench Process

    Energy Technology Data Exchange (ETDEWEB)

    R. A. Cordes; A. Donaldson

    2000-09-01

    The goals of this project included the scale-up of the titanium hydride production process to a production rate of 50 kg/hr at a purity level of 99+%. This goal was to be achieved by incrementally increasing the production capability of a series of reactor systems. This methodic approach was designed to allow Idaho Titanium Technologies to systematically address the engineering issues associated with plasma system performance, and powder collection system design and performance. With quality powder available, actual fabrication with the titanium hydride was to be pursued. Finally, with a successful titanium production system in place, the production of titanium aluminide was to be pursued by the simultaneously injection of titanium and aluminum precursors into the reactor system. Some significant accomplishments of the project are: A unique and revolutionary torch/reactor capable of withstanding temperatures up to 5000 C with high thermal efficiency has been operated. The dissociation of titanium tetrachloride into titanium powder and HC1 has been demonstrated, and a one-megawatt reactor potentially capable of producing 100 pounds per hour has been built, but not yet operated at the powder level. The removal of residual subchlorides and adsorbed HC1 and the sintering of powder to form solid bodies have been demonstrated. The production system has been operated at production rates up to 40 pounds per hour. Subsequent to the end of the project, Idaho Titanium Technologies demonstrated that titanium hydride powder can indeed be sintered into solid titanium metal at 1500 C without sintering aids.

  13. The effect of titanium surface treatment on the interfacial strength of titanium – Thermoplastic composite joints

    NARCIS (Netherlands)

    Su, Yibo; de Rooij, Matthijn; Grouve, Wouter; Akkerman, Remko

    2017-01-01

    Co-consolidated titanium – carbon fibre reinforced thermoplastic composite hybrid joints show potential for application in aerospace structures. The strength of the interface between the titanium and the thermoplastic composite is crucial for the strength of the entire hybrid joint. Application of a

  14. Development and preliminary evaluation of a new anatomically based prosthetic alignment method for below-knee prosthesis.

    Science.gov (United States)

    Tafti, Nahid; Karimlou, Masoud; Mardani, Mohammad Ali; Jafarpisheh, Amir Salar; Aminian, Gholam Reza; Safari, Reza

    2018-04-20

    The objectives of current study were to a) assess similarities and relationships between anatomical landmark-based angles and distances of lower limbs in unilateral transtibial amputees and b) develop and evaluate a new anatomically based static prosthetic alignment method. First sub-study assessed the anthropometrical differences and relationships between the lower limbs in the photographs taken from amputees. Data were analysed via paired t-test and regression analysis. Results show no significant differences in frontal and transverse planes. In the sagittal plane, the anthropometric parameters of the amputated limb were significantly correlated to the corresponding variables of the sound limb. The results served as bases for the development of a new prosthetic alignment method. The method was evaluated on a single subject study. Prosthetic alignment carried out by an experienced prosthetist was compared with such alignment adjusted by an inexperienced prosthetist but with the use of the developed method. In sagittal and frontal planes, the socket angle was tuned with respect to the shin angle, and the position of the prosthetic foot was tuned in relation to the pelvic landmarks. Further study is needed to assess the proposed method on a larger sample of amputees and prosthetists.

  15. Lactam inhibiting Streptococcus mutans growth on titanium

    International Nuclear Information System (INIS)

    Xavier, J.G.; Geremias, T.C.; Montero, J.F.D.; Vahey, B.R.; Benfatti, C.A.M.; Souza, J.C.M.; Magini, R.S.; Pimenta, A.L.

    2016-01-01

    The aim of this work was to analyze the activity of novel synthetic lactams on preventing biofilm formation on titanium surfaces. Titanium (Ti6Al4V) samples were exposed to Streptococcus mutans cultures in the presence or absence of a synthetic lactam. After 48 h incubation, planktonic growth was determined by spectrophotometry. Biofilm was evaluated by crystal violet staining and colony forming units (CFU·ml −1 ), followed by scanning electron microscopy (SEM). Results showed that the average of adhered viable cells was approximately 1.5 × 10 2 CFU/ml in the presence of lactam and 4 × 10 2 CFU/ml in its absence. This novel compound was considerable active in reducing biofilm formation over titanium surfaces, indicating its potential for the development of antimicrobial drugs targeting the inhibition of the initial stages of bacterial biofilms on dental implants abutments. - Highlights: • A novel synthetic compound is tested on preventing biofilm formation on titanium surfaces • Biofilm inhibition has been achieved on titanium surfaces containing the novel compound. • Planktonic growth of S. mutans was not affected by the presence of lactams on titanium.

  16. Lactam inhibiting Streptococcus mutans growth on titanium

    Energy Technology Data Exchange (ETDEWEB)

    Xavier, J.G.; Geremias, T.C.; Montero, J.F.D. [Center for Research on Dental Implants (CEPID), School of Dentistry (ODT), Federal University of Santa Catarina - UFSC, Florianópolis/SC, 88040-900 (Brazil); Vahey, B.R. [Herman Ostrow School of Dentistry of USC, 925 W 34 St, Los Angeles, CA 90089 (United States); Benfatti, C.A.M.; Souza, J.C.M.; Magini, R.S. [Center for Research on Dental Implants (CEPID), School of Dentistry (ODT), Federal University of Santa Catarina - UFSC, Florianópolis/SC, 88040-900 (Brazil); Pimenta, A.L., E-mail: andrea@intelab.ufsc.br [Department of Biologia, ERRMECe, Université de Cergy Pontoise, 2, Av. Adolphe Chauvin 95302 Cergy, Pontoise (France); Integrated Laboratories Technologies (InteLab), Dept. Chemical and Food Engineering (EQA), Federal University of Santa Catarina - UFSC, Florianópolis/SC, 88040-970 (Brazil)

    2016-11-01

    The aim of this work was to analyze the activity of novel synthetic lactams on preventing biofilm formation on titanium surfaces. Titanium (Ti6Al4V) samples were exposed to Streptococcus mutans cultures in the presence or absence of a synthetic lactam. After 48 h incubation, planktonic growth was determined by spectrophotometry. Biofilm was evaluated by crystal violet staining and colony forming units (CFU·ml{sup −1}), followed by scanning electron microscopy (SEM). Results showed that the average of adhered viable cells was approximately 1.5 × 10{sup 2} CFU/ml in the presence of lactam and 4 × 10{sup 2} CFU/ml in its absence. This novel compound was considerable active in reducing biofilm formation over titanium surfaces, indicating its potential for the development of antimicrobial drugs targeting the inhibition of the initial stages of bacterial biofilms on dental implants abutments. - Highlights: • A novel synthetic compound is tested on preventing biofilm formation on titanium surfaces • Biofilm inhibition has been achieved on titanium surfaces containing the novel compound. • Planktonic growth of S. mutans was not affected by the presence of lactams on titanium.

  17. Prosthetic vision: devices, patient outcomes and retinal research.

    Science.gov (United States)

    Hadjinicolaou, Alex E; Meffin, Hamish; Maturana, Matias I; Cloherty, Shaun L; Ibbotson, Michael R

    2015-09-01

    Retinal disease and its associated retinal degeneration can lead to the loss of photoreceptors and therefore, profound blindness. While retinal degeneration destroys the photoreceptors, the neural circuits that convey information from the eye to the brain are sufficiently preserved to make it possible to restore sight using prosthetic devices. Typically, these devices consist of a digital camera and an implantable neurostimulator. The image sensor in a digital camera has the same spatiotopic arrangement as the photoreceptors of the retina. Therefore, it is possible to extract meaningful spatial information from an image and deliver it via an array of stimulating electrodes directly to the surviving retinal circuits. Here, we review the structure and function of normal and degenerate retina. The different approaches to prosthetic implant design are described in the context of human and preclinical trials. In the last section, we review studies of electrical properties of the retina and its response to electrical stimulation. These types of investigation are currently assessing a number of key challenges identified in human trials, including stimulation efficacy, spatial localisation, desensitisation to repetitive stimulation and selective activation of retinal cell populations. © 2015 The Authors. Clinical and Experimental Optometry © 2015 Optometry Australia.

  18. Uptake of radiolabeled leukocytes in prosthetic graft infection

    International Nuclear Information System (INIS)

    Serota, A.I.; Williams, R.A.; Rose, J.G.; Wilson, S.E.

    1981-01-01

    The utility of radionuclide labeled leukocytes in the demonstration of infection within vascular prostheses was examined. The infrarenal aorta was replaced with a 3 cm Dacron graft in 12 dogs. On the third postoperative day, six of the animals received an intravenous injection of 10(8) Staphylococcus aureus. Labeled leukocyte scans were performed at postoperative days one and three, and then weekly for 8 weeks with indium-111 and technetium-99 labeled autologous leukocytes. When scans showed focal uptake of isotope in the area of prosthetic material, the grafts were aseptically excised and cultured on mannitol-salt agar. Both control and infected animals had retroperitoneal isotope activity in the immediate postoperative period that disappeared by the end of the first week. By the eighth postoperative week, all of the animals that received the bacteremic challenge had both radionuclide concentration in the region of the vascular prosthesis and S. aureus cultured subsequently from the perigraft tissues. None of the control animals had either radionuclide or bacteriologic evidence of infection at the eighth postoperative week. The radiolabeled leukocyte scan is a highly sensitive and specific technique, clinically applicable for the diagnosis of vascular prosthetic infections

  19. Rapid Molecular Microbiologic Diagnosis of Prosthetic Joint Infection

    Science.gov (United States)

    Cazanave, Charles; Greenwood-Quaintance, Kerryl E.; Hanssen, Arlen D.; Karau, Melissa J.; Schmidt, Suzannah M.; Gomez Urena, Eric O.; Mandrekar, Jayawant N.; Osmon, Douglas R.; Lough, Lindsay E.; Pritt, Bobbi S.; Steckelberg, James M.

    2013-01-01

    We previously showed that culture of samples obtained by prosthesis vortexing and sonication was more sensitive than tissue culture for prosthetic joint infection (PJI) diagnosis. Despite improved sensitivity, culture-negative cases remained; furthermore, culture has a long turnaround time. We designed a genus-/group-specific rapid PCR assay panel targeting PJI bacteria and applied it to samples obtained by vortexing and sonicating explanted hip and knee prostheses, and we compared the results to those with sonicate fluid and periprosthetic tissue culture obtained at revision or resection arthroplasty. We studied 434 subjects with knee (n = 272) or hip (n = 162) prostheses; using a standardized definition, 144 had PJI. Sensitivities of tissue culture, of sonicate fluid culture, and of PCR were 70.1, 72.9, and 77.1%, respectively. Specificities were 97.9, 98.3, and 97.9%, respectively. Sonicate fluid PCR was more sensitive than tissue culture (P = 0.04). PCR of prosthesis sonication samples is more sensitive than tissue culture for the microbiologic diagnosis of prosthetic hip and knee infection and provides same-day PJI diagnosis with definition of microbiology. The high assay specificity suggests that typical PJI bacteria may not cause aseptic implant failure. PMID:23658273

  20. Titanium. Properties, raw datum surface, physicochemical basis and fabrication technique

    International Nuclear Information System (INIS)

    Garmata, V.A.; Petrun'ko, A.N.; Galitskij, N.V.; Olesov, Yu.G.; Sandler, R.A.

    1983-01-01

    On the nowadays science and technology achievements the complex of titanium metallurgy problems comprising raw material base, physico-chemical basis and fabrication technique, properties and titanium usage fields is considered for the first time. A particular attention is given to raw material base, manufacturing titanium concentrates and titanium tetrachloride, metallothermal reduction, improvement of metal quality. Data on titanium properties are given, processes of titanium powder metallurgy, scrap and waste processing, problems of economics and complex raw material use are considered

  1. Introduction to powder metallurgy processes for titanium manufacturing

    International Nuclear Information System (INIS)

    Esteban, P. G.; Bolzoni, L.; Ruiz-Navas, E. M.; Gordo, E.

    2011-01-01

    The development of new extraction processes to produce titanium in powder form leads Powder Metallurgy to an advantage position among the manufacturing processes for titanium. The cost reduction of base material, coupled with the economy of the powder metallurgy processes, give titanium industry the chance to diversify its products, which could lead to production volumes able to stabilise the price of the metal. This work reviews some of the Powder Metallurgy techniques for the manufacturing of titanium parts, and describes the two typical approaches for titanium manufacturing: Blending Elemental and Prealloyed Powders. Among others, conventional pressing and sintering are described, which are compared with cold and hot isostatic pressing techniques. Real and potential applications are described. (Author) 71 refs.

  2. Evaluation of p53 Polymorphism in Patients with Pannus-Derived Prosthetic Dysfunction.

    Science.gov (United States)

    Gursoy, Mustafa Ozan; Karakoyun, Suleyman; Kalcik, Macit; Yesin, Mahmut; Gunduz, Sabahattin; Astarcioğlu, Mehmet Ali; Oğuz, Ali Emrah; Ozkan, Mehmet

    2015-09-01

    Prosthetic valve dysfunction (PVD) due to pannus formation is considered to occur due to a bioreaction to prosthetic material. The p53 gene plays a critical role in apoptosis and cell proliferation. p53 Arg72Pro polymorphism has been found to be associated with coronary stent restenosis, but has not yet been studied in prosthetic heart valve dysfunction. The study aim was to evaluate the association between pannus-derived PVD and p53 G72C(Arg72Pro) polymorphism. This single-center, prospective study included 25 patients (20 females, five males; mean age 45.6 +/- 12.5 years; group 1) who underwent redo valve surgery due to PVD, and 49 age- and gender-matched control patients (44 females, five males; mean age 47.3 +/- 12.2 years; group 2) with normofunctional prostheses. The prostheses were examined using transthoracic and transesophageal echocardiography. Analyses of p53 G72C(Arg72Pro) polymorphism were performed using Roche LightCyler 2.0 Real-time polymerase chain reaction. The most common location of replaced valves was the mitral position in both groups (88% and 89.8%, respectively). In group 1, normal alleles (GG) were observed in 12 patients (48%), while one patient (4%) showed a homozygous mutation (GC) and 12 patients (48%) showed a heterozygous mutation (CC). In group 2, 21 patients (42.9%) had normal alleles (GG), while four (8.2%) had a homozygous mutation (CC) and 24 (48.9%) had a heterozygous mutation (GC). No significant difference was observed between the groups with regards to p53 Arg72Pro polymorphism (p = 0.769). In patients with prosthetic valves, the underlying mechanism behind pannus formation is unrelated to p53 Arg72Pro polymorphism.

  3. Microwave assisted scalable synthesis of titanium ferrite nanomaterials

    Science.gov (United States)

    Shukla, Abhishek; Bhardwaj, Abhishek K.; Singh, S. C.; Uttam, K. N.; Gautam, Nisha; Himanshu, A. K.; Shah, Jyoti; Kotnala, R. K.; Gopal, R.

    2018-04-01

    Titanium ferrite magnetic nanomaterials are synthesized by one-step, one pot, and scalable method assisted by microwave radiation. Effects of titanium content and microwave exposure time on size, shape, morphology, yield, bonding nature, crystalline structure, and magnetic properties of titanium ferrite nanomaterials are studied. As-synthesized nanomaterials are characterized by X-ray diffraction (XRD), ultraviolet-visible absorption spectroscopy (UV-Vis), attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR), Raman spectroscopy, transmission electron microscopy (TEM), and vibrating sample magnetometer measurements. XRD measurements depict the presence of two phases of titanium ferrite into the same sample, where crystallite size increases from ˜33 nm to 37 nm with the increase in titanium concentration. UV-Vis measurement showed broad spectrum in the spectral range of 250-600 nm which reveals that its characteristic peaks lie between ultraviolet and visible region; ATR-FTIR and Raman measurements predict iron-titanium oxide structures that are consistent with XRD results. The micrographs of TEM and selected area electron diffraction patterns show formation of hexagonal shaped particles with a high degree of crystallinity and presence of multi-phase. Energy dispersive spectroscopy measurements confirm that Ti:Fe compositional mass ratio can be controlled by tuning synthesis conditions. Increase of Ti defects into titanium ferrite lattice, either by increasing titanium precursor or by increasing exposure time, enhances its magnetic properties.

  4. Adaptive mesh refinement in titanium

    Energy Technology Data Exchange (ETDEWEB)

    Colella, Phillip; Wen, Tong

    2005-01-21

    In this paper, we evaluate Titanium's usability as a high-level parallel programming language through a case study, where we implement a subset of Chombo's functionality in Titanium. Chombo is a software package applying the Adaptive Mesh Refinement methodology to numerical Partial Differential Equations at the production level. In Chombo, the library approach is used to parallel programming (C++ and Fortran, with MPI), whereas Titanium is a Java dialect designed for high-performance scientific computing. The performance of our implementation is studied and compared with that of Chombo in solving Poisson's equation based on two grid configurations from a real application. Also provided are the counts of lines of code from both sides.

  5. [The bonding characteristic of titanium and RG experiment porcelain].

    Science.gov (United States)

    Ren, Wei-hong; Guo, Tian-wen; Tian, Jie-mo; Zhang, Yun-long

    2003-07-01

    To study the bonding characteristic of Titanium and RG experiment porcelain. 5 specimens with a size of 10 mm x 5 mm x 1.4 mm were cast from pure titanium. Then 1 mm of RG experiment opaque and body porcelain were fused on the surface of the titanium specimens. The interface of titanium and porcelain was analyzed with a scanning electron microscope with energy-despersive spectrometry; 6 metal specimens with the size of 25 mm x 3 mm x 0.5 mm were cast from Ni-Cr alloy and a uniform thickness of 1 mm of VMK 99 porcelain was veneered on the central area of 8 mm x 3 mm 18 metal specimens as the same size were cast from pure titanium. The uniform thickness of 1 mm of VITA TITANKERAMIK porcelain, of Noritake super porcelain Ti-22 and of RG experiment porcelain were veneered on every 6 specimens respectively in the central area of 8 mm x 3 mm. The specimens were subjected to a three-point bending test on a load-test machine with a span of 20 mm, then the failure loads were recorded and statistically analysised. The RG porcelain/titanium crown was fabricated by fusing RG opaque porcelain and body porcelain to cast titanium substrate crown. The SEM results show no porosity and crackle were found in the interface. The energy-dispersive spectrometry show that there are Si, Ti and O in the 1 micro m layer between porcelain and titanium, which suggesting titanium and experiment porcelain bonding well. The three point test showed the fracture force for the combinations of titanium/VITA TITANKERAMIK porcelain, titanium/Noritake super porcelain Ti-22 and titanium/RG experiment porcelain were (7.233 +/- 2.539) N, (5.533 +/- 1.199) N and (6.316 +/- 1.433) N respectively. There were not statistically significant differences among them (t test, P porcelain combination (12.733 +/- 3.297) N was significantly greater than those of the cast titanium/porcelain (t test, P > 0.05). The crown was translucent with no crack. RG porcelain is well compatible with titanium.

  6. Formation of titanium nitride layers on titanium metal: Results of XPS and AES investigations

    International Nuclear Information System (INIS)

    Moers, H.; Pfennig, G.; Klewe-Nebenius, H.; Penzhorn, R.D.; Sirch, M.; Willin, E.

    1988-09-01

    The reaction of titanium metal with gaseous nitrogen and ammonia at temperatures of 890 0 C leads to the formation of nitridic overlayers on the metallic substrate. The thicknesses of the overlayers increase with increasing reaction time. Under comparable conditions ammonia reacts much slower than nitrogen. XPS and AES depth profile analyses show continuous changes of the in-depth compositions of the overlayers. This can be interpreted in terms of a very irregular thickness of the overlayers, an assumption which is substantiated by local AES analyses and by the observation of a pronounced crystalline structure of the substrate after annealing pretreatment, which can give rise to locally different reaction rates. The depth profile is also influenced by the broad ranges of stability of the titanium nitride phases formed during the reaction. The quantitative analysis of the titanium/nitrogen overlayers by AES is difficult because of the overlap of titanium and nitrogen Auger peaks. In quantitative XPS analysis problems arise due to difficulties in defining Ti 2p peak areas. This work presents practical procedures for the quantitative evaluation by XPS and AES of nitridic overlayers with sufficient accuracy. (orig.) [de

  7. A personalized 3D-printed prosthetic joint replacement for the human temporomandibular joint: From implant design to implantation.

    Science.gov (United States)

    Ackland, David C; Robinson, Dale; Redhead, Michael; Lee, Peter Vee Sin; Moskaljuk, Adrian; Dimitroulis, George

    2017-05-01

    Personalized prosthetic joint replacements have important applications in cases of complex bone and joint conditions where the shape and size of off-the-shelf components may not be adequate. The objective of this study was to design, test and fabricate a personalized 3D-printed prosthesis for a patient requiring total joint replacement surgery of the temporomandibular joint (TMJ). The new 'Melbourne' prosthetic TMJ design featured a condylar component sized specifically to the patient and fixation screw positions that avoid potential intra-operative damage to the mandibular nerve. The Melbourne prosthetic TMJ was developed for a 58-year-old female recipient with end-stage osteoarthritis of the TMJ. The load response of the prosthesis during chewing and a maximum-force bite was quantified using a personalized musculoskeletal model of the patient's masticatory system developed using medical images. The simulations were then repeated after implantation of the Biomet Microfixation prosthetic TMJ, an established stock device. The maximum condylar stresses, screw stress and mandibular stress at the screw-bone interface were lower in the Melbourne prosthetic TMJ (259.6MPa, 312.9MPa and 198.4MPa, respectively) than those in the Biomet Microfixation device (284.0MPa, 416.0MPa and 262.2MPa, respectively) during the maximum-force bite, with similar trends also observed during the chewing bite. After trialing surgical placement and evaluating prosthetic TMJ stability using cadaveric specimens, the prosthesis was fabricated using 3D printing, sterilized, and implanted into the female recipient. Six months post-operatively, the prosthesis recipient had a normal jaw opening distance (40.0 mm), with no complications identified. The new design features and immediate load response of the Melbourne prosthetic TMJ suggests that it may provide improved clinical and biomechanical joint function compared to a commonly used stock device, and reduce risk of intra-operative nerve damage

  8. Clinical bending of nickel titanium wires

    Directory of Open Access Journals (Sweden)

    Stephen Chain

    2015-01-01

    Full Text Available Since the evolution and the involvement of Nickel Titanium wires in the field of Orthodontics. The treatment plan has evolved with the use of low force Nickel Titanium wires. Because of their high springback, low stiffness, they are the key initial wires in leveling and alignment but have poor formability. Since poor formability limits its ability to create variable arch forms thus; limits the form of treatment. We have devised a method to bend the Nickel Titanium wires to help in our inventory but also customized the wire according to the treatment.

  9. Isothermal deformation of gamma titanium aluminide

    International Nuclear Information System (INIS)

    Srinivasan, R.; Singh, J.P.; Tuval, E.; Weiss, I.

    1996-01-01

    Gamma titanium aluminide has received considerable attention in recent years from the automotive industry as a potential material for making rotating and reciprocating components to produce a quieter and more efficient engine. The objectives of this study were to identify processing routes for the manufacture of automobile valves from gamma titanium aluminide. The issues considered were microstructure and composition of the material, and processing parameters such as deformation rates, temperatures, and total deformation. This paper examines isothermal deformation of gamma titanium aluminide in order to develop a processing window for this type of material

  10. Titanium: the innovators metal. Historical case studies tracing titanium process and product innovation [Conference paper

    CSIR Research Space (South Africa)

    Oosthuizen, SJ

    2010-10-01

    Full Text Available Magn Reson., Vol 4, Pp. 423–430. 18. Branemark, P. 1983. Osseointegration and its experimental background. The Journal of Prosthetic Dentistry, Vol 50. Pp 399-410. 19. Brånemark Osseointegration Center. 2009. [Online] Available from: http...

  11. Titanium: the innovators’ metal. Historical case studies tracing titanium process and product innovation [Journal Article

    CSIR Research Space (South Africa)

    Oosthuizen, SJ

    2011-11-01

    Full Text Available . pp. 423?430. 18. BRANEMARK, P. Osseointegration and its experimental background. Journal of Prosthetic Dentistry, vol. 50, 1983. pp. 399?410. 19. Br?nemark Osseointegration Center. [Online] http://www.branemark.com/ Accessed: 15-03-2009. 2009. 20...

  12. Secure Microprocessor-Controlled Prosthetic Leg for Elderly Amputees: Preliminary Results

    Directory of Open Access Journals (Sweden)

    S. Krut

    2011-01-01

    Full Text Available We introduce a new prosthetic leg design, adapted to elderly trans-femoral amputees. Technical progress in prosthesis design mainly concerns active individuals. An important number of elderly amputees are not very mobile, tire easily, present reduced muscle strength, and have difficulties managing their balance. Therefore, the needs and characteristics of this specific population are very different from those of younger ones and the prosthetic solutions are not adapted. Our artificial knee has been designed to fulfill the specific requirements of this population in terms of capabilities, transfer assistance, security, intuitiveness, simplicity of use, and types of physical activity to be performed. We particularly focused our efforts on ensuring safe and secure stand-to-sit transfers. We developed an approach to control the different states of the prosthetic joint (blocked, free, resistant, associated with different physical activities. Amputee posture and motion are observed through a single multi-axis force sensor embedded in the prosthesis. The patient behaves naturally, while the controller analyses his movements in order to detect his intention to sit down. The detection algorithm is based on a reference pattern, calibrated individually, to which the sensor data are compared, and submitted to a set of tests allowing the discrimination of the intention to sit down from other activities. Preliminary validation of the system has been performed in order to verify the applicability of the prosthesis to different tasks: walking, standing, sitting down, standing up, picking up an object from a chair, slope and stair climbing.

  13. Iodine-125 orbital brachytherapy with a prosthetic implant in situ

    Energy Technology Data Exchange (ETDEWEB)

    Stannard, Clare [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Radiation Oncology; Maree, Gert; Munro, Roger [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Medical Physics; Lecuona, Karin [Groote Schuur Hospital and Cape Town Univ. (South Africa). Dept. of Ophthalmology; Sauerwein, Wolfgang [Universitaetsklinikum Essen (Germany). Strahlenklinik, NCTeam

    2011-05-15

    Purpose: Brachytherapy is one method of irradiating the orbit after enucleation of an eye with a malignant tumor that has a potential to recur. It consists of 6 trains of I-125 seeds placed around the periphery of the orbit, a shorter central train, and a metal disc, loaded with seeds, placed beneath the eyelids. The presence of a prosthetic orbital implant requires omission of the central train and adjustment of the activity of the seeds in the anterior orbit around the prosthesis. Patients and Methods: This is a retrospective review of the technical modifications and outcome of 12 patients treated in this manner: 6 with retinoblastoma, 5 with malignant melanoma, and 1 with an intraocular rhabdomyosarcoma. The median dose was 35.5 Gy in 73 hours for retinoblastoma and 56 Gy in 141 hours for malignant melanoma. Patients with retinoblastoma and rhabdomyosarcoma also received chemotherapy. Results: The tubes can be placed satisfactorily around the prosthesis. The increased activity in the anterior half of the tubes produced comparable dose distributions. There have been no orbital recurrences, no extrusion of the prosthesis, and cosmesis is good. Conclusion: Insertion of a prosthetic implant at the time of enucleation greatly enhances the subsequent cosmetic appearance. This should be encouraged unless there is frank tumor in the orbit. Orbital brachytherapy without the central train continues to give excellent local control. The short treatment time and good cosmesis are added advantages. The patient is spared the expense and inconvenience of removing and replacing the prosthetic implant. (orig.)

  14. Orthodontic Space Closure Versus Prosthetic Replacement of Missing Upper Lateral Incisors in Patients With Bilateral Cleft Lip and Palate

    NARCIS (Netherlands)

    Oosterkamp, Barbara C. M.; Dijkstra, Pieter U.; Remmelink, Hendrik J.; van Oort, Robert P.; Sandham, John

    2010-01-01

    Objective To compare dental aesthetics and function of orthodontic space closure versus prosthetic replacement of upper lateral incisors in patients with bilateral cleft lip and palate The predominant mode of prosthetic replacement was resin-bonded bridges Patients and Methods The retrospective

  15. Printing of Titanium implant prototype

    International Nuclear Information System (INIS)

    Wiria, Florencia Edith; Shyan, John Yong Ming; Lim, Poon Nian; Wen, Francis Goh Chung; Yeo, Jin Fei; Cao, Tong

    2010-01-01

    Dental implant plays an important role as a conduit of force and stress to flow from the tooth to the related bone. In the load sharing between an implant and its related bone, the amount of stress carried by each of them directly related to their stiffness or modulus. Hence, it is a crucial issue for the implant to have matching mechanical properties, in particular modulus, between the implant and its related bone. Titanium is a metallic material that has good biocompatibility and corrosion resistance. Whilst the modulus of the bulk material is still higher than that of bone, it is the lowest among all other commonly used metallic implant materials, such as stainless steel or cobalt alloy. Hence it is potential to further reduce the modulus of pure Titanium by engineering its processing method to obtain porous structure. In this project, porous Titanium implant prototype is fabricated using 3-dimensional printing. This technique allows the flexibility of design customization, which is beneficial for implant fabrication as tailoring of implant size and shape helps to ensure the implant would fit nicely to the patient. The fabricated Titanium prototype had a modulus of 4.8-13.2 GPa, which is in the range of natural bone modulus. The compressive strength achieved was between 167 to 455 MPa. Subsequent cell culture study indicated that the porous Titanium prototype had good biocompatibility and is suitable for bone cell attachment and proliferation.

  16. Cryopreserved Cadaveric Arterial Allograft for Arterial Reconstruction in Patients with Prosthetic Infection.

    Science.gov (United States)

    Lejay, Anne; Delay, Charline; Girsowicz, Elie; Chenesseau, Bettina; Bonnin, Emilie; Ghariani, Mohamed-Zied; Thaveau, Fabien; Georg, Yannick; Geny, Bernard; Chakfe, Nabil

    2017-11-01

    The aim of this study was to report outcomes of cryopreserved arterial allografts used as a vascular substitute in the setting of prosthetic material infection. A retrospective analysis of prospectively collected data was conducted including all consecutive interventions performed with cryopreserved arterial allografts used for vascular reconstruction in the setting of prosthetic material infection between January 2005 and December 2014. Five year outcomes included allograft related re-interventions, survival, primary patency, and limb salvage rates. Fifty-three procedures were performed using cryopreserved allografts for vascular prosthetic infection: 25 procedures (47%) were performed at aorto-iliac level (Group 1) and 28 procedures (53%) at peripheral level (Group 2). The mean follow-up was 52 months. Five year allograft related re-intervention was 55% in Group 1 (6 allograft ruptures and 5 allograft aneurysm degenerations) and 33% in Group 2 (2 allograft ruptures and 7 allograft aneurysm degenerations). Five year survival was 40% and 68%, primary patency was 89% and 59% and limb salvage was 100% and 89% for Group 1 and 2 respectively. Use of cryopreserved arterial allografts provides acceptable results but is tempered by suboptimal 5 year outcomes with high re-intervention rates. Copyright © 2017 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

  17. Recurrent pannus formation causing prosthetic aortic valve dysfunction: Is excision without valve re-replacement applicable?

    Directory of Open Access Journals (Sweden)

    Darwazah Ahmad K

    2012-06-01

    Full Text Available Abstract Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function. The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement. A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve. Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function.

  18. [Ectodermal Capdepont syndrome and oral prosthetic rehabilitation. About a clinical case].

    Science.gov (United States)

    Kumpanya, P; Matshumba, M; Sekele, I B; Mayunga, M; Lutula, P S; Ntumba, M K

    2015-03-01

    The authors describe the ectodermal Capdepont syndrome as an anomaly characterized by anhidrosis, hypotrichosis and anodontia diagnosed in a 22 year-old adult. In front of this anodontia, oral prosthetic rehabilitation remains the only solution.

  19. Design and clinical outcome of a novel 3D-printed prosthetic joint replacement for the human temporomandibular joint.

    Science.gov (United States)

    Ackland, David; Robinson, Dale; Lee, Peter Vee Sin; Dimitroulis, George

    2018-05-11

    Stock prosthetic temporomandibular joint replacements come in limited sizes, and do not always encompass the joint anatomy that presents clinically. The aims of this study were twofold. Firstly, to design a personalized prosthetic total joint replacement for the treatment of a patient's end-stage temporomandibular joint osteoarthritis, to implant the prosthesis into the patient, and assess clinical outcome 12-months post-operatively; and secondly, to evaluate the influence of changes in prosthetic condyle geometry on implant load response during mastication. A 48-year-old female patient with Grade-5 osteoarthritis to the left temporomandibular joint was recruited, and a prosthesis developed to match the native temporomandibular joint anatomy. The prosthesis was 3D printed, sterilized and implanted into the patient, and pain and function measured 12-months post-operatively. The prosthesis load response during a chewing-bite and maximum-force bite was evaluated using a personalized multi-body musculoskeletal model. Simulations were performed after perturbing condyle thickness, neck length and head sphericity. Increases in prosthetic condyle neck length malaligned the mandible and perturbed temporomandibular joint force. Changes in condylar component thickness greatly influenced fixation screw stress response, while a more eccentric condylar head increased prosthetic joint-contact loading. Post-operatively, the prosthetic temporomandibular joint surgery reduced patient pain from 7/10 to 1/10 on a visual analog scale, and increased intercisal opening distance from 22 mm to 38 mm. This study demonstrates effectiveness of a personalized prosthesis that may ultimately be adapted to treat a wide-range of end-stage temporomandibular joint conditions, and highlights sensitivity of prosthesis load response to changes in condylar geometry. Copyright © 2018 Elsevier Ltd. All rights reserved.

  20. Oversizing and Restenosis with Self-Expanding Stents in Iliofemoral Arteries

    International Nuclear Information System (INIS)

    Saguner, Ardan M.; Traupe, Tobias; Räber, Lorenz; Hess, Nina; Banz, Yara; Saguner, Arhan R.; Diehm, Nicolas; Hess, Otto M.

    2012-01-01

    Purpose: Uncoated self-expanding nitinol stents (NS) are commonly oversized in peripheral arteries. In current practice, 1-mm oversizing is recommended. Yet, oversizing of NS may be associated with increased restenosis. To provide further evidence, NS were implanted in porcine iliofemoral arteries with a stent-to-artery-ratio between 1.0 and 2.3. Besides conventional uncoated NS, a novel self-expanding NS with an antiproliferative titanium-nitride-oxide (TiNOX) coating was tested for safety and efficacy. Methods: Ten uncoated NS and six TiNOX-coated NS (5–6 mm) were implanted randomly in the iliofemoral artery of six mini-pigs. After implantation, quantitative angiography (QA) was performed for calculation of artery and minimal luminal diameter. Follow-up was performed by QA and histomorphometry after 5 months. Results: Stent migration, stent fracture, or thrombus formation were not observed. All stents were patent at follow-up. Based on the location of the stent (iliac/femoral) and the stent-to-artery-ratio, stent segments were divided into “normal-sized” (stent-to-artery-ratio < 1.4, n = 12) and “oversized” (stent-to-artery-ratio ≥ 1.4, n = 9). All stent segments expanded to their near nominal diameter during follow-up. Normal-sized stent segments increased their diameter by 6% and oversized segments by 29%. A significant correlation between oversizing and restenosis by both angiography and histomorphometry was observed. Restenosis rates were similar for uncoated NS and TiNOX-coated NS. Conclusions: TiNOX-coated NS are as safe and effective as uncoated NS in the porcine iliofemoral artery. All stents further expand to near their nominal diameter during follow-up. Oversizing is linearly and positively correlated with neointimal proliferation and restenosis, which may not be reduced by TiNOX-coating.

  1. Iron-titanium-mischmetal alloys for hydrogen storage

    Science.gov (United States)

    Sandrock, Gary Dale

    1978-01-01

    A method for the preparation of an iron-titanium-mischmetal alloy which is used for the storage of hydrogen. The alloy is prepared by air-melting an iron charge in a clay-graphite crucible, adding titanium and deoxidizing with mischmetal. The resultant alloy contains less than about 0.1% oxygen and exhibits a capability for hydrogen sorption in less than half the time required by vacuum-melted, iron-titanium alloys.

  2. Production of titanium from ilmenite: a review

    Energy Technology Data Exchange (ETDEWEB)

    Kohli, R.

    1981-12-01

    The general principles for beneficiation of titanium ores are reviewed and the specific processes used in individual units in various countries are discussed. This is followed by a critical evaluation of various current and potential reduction methods for the production of titanium metal from the processed concentrates. Finally, the report outlines a research program for the development of a commercially viable alternative method for the production of titanium metal.

  3. The Prosthetic Workflow in the Digital Era

    Directory of Open Access Journals (Sweden)

    Lidia Tordiglione

    2016-01-01

    Full Text Available The purpose of this retrospective study was to clinically evaluate the benefits of adopting a full digital workflow for the implementation of fixed prosthetic restorations on natural teeth. To evaluate the effectiveness of these protocols, treatment plans were drawn up for 15 patients requiring rehabilitation of one or more natural teeth. All the dental impressions were taken using a Planmeca PlanScan® (Planmeca OY, Helsinki, Finland intraoral scanner, which provided digital casts on which the restorations were digitally designed using Exocad® (Exocad GmbH, Germany, 2010 software and fabricated by CAM processing on 5-axis milling machines. A total of 28 single crowns were made from monolithic zirconia, 12 vestibular veneers from lithium disilicate, and 4 three-quarter vestibular veneers with palatal extension. While the restorations were applied, the authors could clinically appreciate the excellent match between the digitally produced prosthetic design and the cemented prostheses, which never required any occlusal or proximal adjustment. Out of all the restorations applied, only one exhibited premature failure and was replaced with no other complications or need for further scanning. From the clinical experience gained using a full digital workflow, the authors can confirm that these work processes enable the fabrication of clinically reliable restorations, with all the benefits that digital methods bring to the dentist, the dental laboratory, and the patient.

  4. Illusory movement perception improves motor control for prosthetic hands.

    Science.gov (United States)

    Marasco, Paul D; Hebert, Jacqueline S; Sensinger, Jon W; Shell, Courtney E; Schofield, Jonathon S; Thumser, Zachary C; Nataraj, Raviraj; Beckler, Dylan T; Dawson, Michael R; Blustein, Dan H; Gill, Satinder; Mensh, Brett D; Granja-Vazquez, Rafael; Newcomb, Madeline D; Carey, Jason P; Orzell, Beth M

    2018-03-14

    To effortlessly complete an intentional movement, the brain needs feedback from the body regarding the movement's progress. This largely nonconscious kinesthetic sense helps the brain to learn relationships between motor commands and outcomes to correct movement errors. Prosthetic systems for restoring function have predominantly focused on controlling motorized joint movement. Without the kinesthetic sense, however, these devices do not become intuitively controllable. We report a method for endowing human amputees with a kinesthetic perception of dexterous robotic hands. Vibrating the muscles used for prosthetic control via a neural-machine interface produced the illusory perception of complex grip movements. Within minutes, three amputees integrated this kinesthetic feedback and improved movement control. Combining intent, kinesthesia, and vision instilled participants with a sense of agency over the robotic movements. This feedback approach for closed-loop control opens a pathway to seamless integration of minds and machines. Copyright © 2018 The Authors, some rights reserved; exclusive licensee American Association for the Advancement of Science. No claim to original U.S. Government Works.

  5. Corrosion resistance of titanium alloys for dentistry

    International Nuclear Information System (INIS)

    Laskawiec, J.; Michalik, R.

    2001-01-01

    Titanium and its alloys belong to biomaterials which the application scope in medicine increases. Some properties of the alloys, such as high mechanical strength, low density, low Young's modulus, high corrosion resistance and good biotolerance decide about it. The main areas of the application of titanium and its alloys are: orthopedics and traumatology, cardiosurgery, faciomaxillary surgery and dentistry. The results of investigations concerning the corrosion resistance of the technical titanium and Ti6Al14V alloy and comparatively a cobalt alloy of the Vitallium type in the artificial saliva is presented in the work. Significantly better corrosion resistance of titanium and the Ti6Al14V than the Co-Cr-Mo alloy was found. (author)

  6. On the solubility of hydrogen in the systems titanium-aluminium-hydrogen, titanium-vanadium-hydrogen and titanium-aluminium-vanadium-hydrogen in the temperature region of 800 to 1,0000C at hydrogen pressures of 0.1 to 400 mm.Hg

    International Nuclear Information System (INIS)

    Kauder, G.W.

    1973-01-01

    The hydrogen concentrations on Ti-Al, Ti-V and Ti-Al-V alloys were determined in the temperature region from 800 to 1,000 0 C and at hydrogen pressures of 0.1 to 400 mm.Hg using a gravimetric measuring process. The thus obtained results allowed the drawing of hydrogen activity slopes in the titanium rich corner of the systems titanium-hydrogen, titanium-aluminium-hydrogen, titanium-vanadium-hydrogen and such for the technical titanium alloys Ti-6Al-4V and Ti-6Al-6V. In spite of the antagonistic effects of the elements aluminium and vanadium on the stabilization of the α and β phase regions of titanium, a hydrogen-activity-increasing effect was always found in which the aluminium influence was greater than that of vanadium. Breaks occured in the hydrogen activity curves and phase boundaries, and phase regions were determined over their positions. Isothermal phase diagrams for the titanium-rich corner of the system titanium-aluminium-hydrogen at 800, 850 and 900 0 C and for the titanium-rich corner of the titanium-vanadium-hydrogen system at 900, 950 and 1,000 0 C were drawn up from the hydrogen activity curves. (orig./LH) [de

  7. Ionic implantation by plasma in titanium and stainless steels used in prosthesis and medical instruments; Implantacion ionica por plasma en titanio y aceros inoxidables usados en protesis e instrumental medico

    Energy Technology Data Exchange (ETDEWEB)

    Munoz C, A. E. [ININ, 52750 La Marquesa, Estado de Mexico (Mexico)

    2008-07-01

    A study of a process known as plasma immersion ion implantation (PIII) of nitrogen at low voltages (< 4 kV) into three kind of samples: 1) austenitic stainless AISI 316-L steel plates, 2) ferritic stainless AISI 434 steel-based dentistry drills and 3) commercially pure titanium (CPTi) disks. On the case of CPTi the study was conducted in nitrogen- oxygen calibrated mixtures: 90% N-10% O, 80% N-20% O, 70% N-30% O and in 99.5% pure oxygen and 99.9% pure nitrogen. The PIII process was carried out by using a direct current plasma source controlled both in voltage and current, a negative voltage pulse modulator, a stainless AISI 304 steel vacuum chamber and a rod of the same material, horizontally located in the upper region of the chamber, which plays the role of anode in the plasma discharge. The purpose of the nitriding is forming a relatively thick layer on the surface of the steel specimens in order to enhance their both microhardness and general corrosion performances, desirable in medical applications. This layer contains interstitial nitrogen atoms ({approx}24% at.) which gives place to a deformed lattice (expanded phase) of the steel. Vickers microhardness and potentiodynamic tests (the latter in agreement to the norm ASTM G-61-89) confirm an increase of microhardness up to three times and a decrease of general corrosion rate in one order of magnitude. The nitriding of de dentistry drills is aimed at inhibiting the pitting corrosion produced by the asepsis process which results in pit nucleations, their propagation and consequent fractures when being under cyclic stress (fatigue). Scanning electron microscope micrographs reveal the risks involved in surpassing the critical treatment simple temperature of 450 C as the PIII process itself induces pitting. On its part, cyclic (ASTM G-61) potentiodynamic tests indicate an excellent pitting corrosion resistance of the samples treated under 450 C. In turn, the treatment of CPTi was meant to develop oxidized and

  8. Ball bearings comprising nickel-titanium and methods of manufacture thereof

    Science.gov (United States)

    DellaCorte, Christopher (Inventor); Glennon, Glenn N. (Inventor)

    2012-01-01

    Disclosed herein is a friction reducing nickel-titanium composition. The nickel-titanium composition includes a first phase that comprises nickel and titanium in an atomic ratio of about 0.45:0.55 to about 0.55:0.45; a second phase that comprises nickel and titanium in an atomic ratio of about 0.70:0.30 to about 0.80:0.20; and a third phase that comprises nickel and titanium in an atomic ratio of about 0.52:0.48 to about 0.62:0.38. A bearing for reducing friction comprising a nickel-titanium composition comprising a first phase that comprises nickel and titanium in an atomic ratio of about 0.45:0.55 to about 0.55:0.45; a second phase that comprises nickel and titanium in an atomic ratio of about 0.70:0.30 to about 0.80:0.20; and a third phase that comprises nickel and titanium in an atomic ratio of about 0.52:0.48 to about 0.62:0.38; where the bearing is free from voids and pinholes.

  9. Prosthetic rehabilitation of a patient after partial maxillectomy: A clinical report

    OpenAIRE

    Rodrigues, Shobha J.; Saldanha, Sharon

    2011-01-01

    Malignant melanoma of the oral cavity is very rare. This clinical report describes a method for prosthetic rehabilitation of a patient with malignant melanoma of the palate following partial maxillectomy with a closed hollow interim obturator.

  10. Machining of titanium alloys

    CERN Document Server

    2014-01-01

    This book presents a collection of examples illustrating the resent research advances in the machining of titanium alloys. These materials have excellent strength and fracture toughness as well as low density and good corrosion resistance; however, machinability is still poor due to their low thermal conductivity and high chemical reactivity with cutting tool materials. This book presents solutions to enhance machinability in titanium-based alloys and serves as a useful reference to professionals and researchers in aerospace, automotive and biomedical fields.

  11. Effects of prosthesis use on the capability to control myoelectric robotic prosthetic hands.

    Science.gov (United States)

    Atzori, Manfredo; Hager, Anne-Gabrielle Mittaz; Elsig, Simone; Giatsidis, Giorgio; Bassetto, Franco; Muller, Henning

    2015-08-01

    The natural control of robotic prosthetic hands with non-invasive techniques is still a challenge: myoelectric prostheses currently give some control capabilities; the application of pattern recognition techniques is promising and recently started to be applied in practice but still many questions are open in the field. In particular, the effects of clinical factors on movement classification accuracy and the capability to control myoelectric prosthetic hands are analyzed in very few studies. The effect of regularly using prostheses on movement classification accuracy has been previously studied, showing differences between users of myoelectric and cosmetic prostheses. In this paper we compare users of myoelectric and body-powered prostheses and intact subjects. 36 machine-learning methods are applied on 6 amputees and 40 intact subjects performing 40 movements. Then, statistical analyses are performed in order to highlight significant differences between the groups of subjects. The statistical analyses do not show significant differences between the two groups of amputees, while significant differences are obtained between amputees and intact subjects. These results constitute new information in the field and suggest new interpretations to previous hypotheses, thus adding precious information towards natural control of robotic prosthetic hands.

  12. Multidisciplinary Treatment Approach for Prosthetic Vascular Graft Infection in the Thoracic Aortic Area

    Science.gov (United States)

    Watanabe, Yoshinori

    2015-01-01

    Prosthetic vascular graft infection in the thoracic aortic area is a rare but serious complication. Adequate management of the complication is essential to increase the chance of success of open surgery. While surgical site infection is suggested as the root cause of the complication, it is also related to decreased host tolerance, especially as found in elderly patients. The handling of prosthetic vascular graft infection has been widely discussed to date. This paper mainly provides a summary of literature reports published within the past 5 years to discuss issues related to multidisciplinary treatment approaches, including surgical site infection, timing of onset, diagnostic methods, causative pathogens, auxiliary diagnostic methods, antibiotic treatment, anti-infective structures of vascular prostheses, surgical treatment, treatment strategy against infectious aortic aneurysms, future surgical treatment, postoperative systemic therapy, and antimicrobial stewardship. A thorough understanding of these issues will enable us to prevent prosthetic vascular graft infection in the thoracic aortic area as far as possible. In the event of its occurrence, the early introduction of appropriate treatment is expected to cure the disease without worsening of the underlying pathological condition. PMID:26356686

  13. Treatment Challenges of Prosthetic Hip Infection with Associated Iliacus Muscle Abscess: Report of 5 Cases and Literature Review.

    Science.gov (United States)

    Lawrenz, Joshua M; Mesko, Nathan W; Higuera, Carlos A; Molloy, Robert M; Simpfendorfer, Claus; Babic, Maja

    2017-01-01

    Prosthetic joint infection is an unfortunate though well-recognized complication of total joint arthroplasty. An iliacus and/or iliopsoas muscle abscess is a rarely documented presentation of hip prosthetic joint infection. It is thought an unrecognized retroperitoneal nidus of infection can be a source of continual seeding of the prosthetic hip joint, prolonging attempts to eradicate infection despite aggressive debridement and explant attempts. The current study presents five cases demonstrating this clinical scenario, and discusses various treatment challenges. In each case we report the patient's clinical history, pertinent imaging, management and outcome. Diagnosis of the iliacus muscle abscess was made using computed tomography imaging. In brief, the mean number of total drainage procedures (open and percutaneous) per patient was 4.2, and outcomes consisted of one patient with a hip girdlestone, two patients with delayed revisions, and two patients with retained prosthesis. All patients ended with functional pain and on oral antibiotic suppression with an average follow up of 18 months. This article highlights an iliacus muscle abscess as an unrecognized source of infection to a prosthetic hip. It demonstrates resilience to standard treatment protocols for prosthetic hip infection, and is associated with poor patient outcomes. Aggressive surgical debridement appears to remain critical to treatment success, and early retroperitoneal debridement of the abscess should be considered.

  14. High pressure sintering (HP-HT) of diamond powders with titanium and titanium carbide

    International Nuclear Information System (INIS)

    Jaworska, L.

    1999-01-01

    Polycrystalline diamond compacts for cutting tools are mostly manufactured using high pressure sintering (HP-HT). The standard diamond compacts are prepared by diamond powders sintering with metallic binding phase. The first group of metallic binder are metals able to solve carbon - Co, Ni. The second group of metal binders are carbide forming elements - Ti, Cr, W and others. The paper describes high pressure sintering of diamond powder with titanium and nonstoichiometry titanium carbide for cutting tool application. A type of binding phase has the significant influence on microstructure and mechanical properties of diamond compacts. Very homogeneous structure was achieved in case of compacts obtained from metalized diamond where diamond-TiC-diamond connection were predominant. In the case of compacts prepared by mechanical mixing of diamond with titanium powders the obtained structure was nonhomogeneous with titanium carbide clusters. They had more diamond to diamond connections. These compacts compared to the compact made of metallized diamond have greater wear resistance. In the case of the diamond and TiC 0.92 sintering the strong bonding of TiC diamond grains was obtained. The microstructure observations for diamond with 5% wt. Ti and diamond with 5% wt. TiC 0.92 (the initial composition) compacts were performed in transmission microscope. For two type of compacts the strong bonding phase TiC without defects is creating. (author)

  15. A three-dimensional finite element study on the stress distribution pattern of two prosthetic abutments for external hexagon implants.

    Science.gov (United States)

    Moreira, Wagner; Hermann, Caio; Pereira, Jucélio Tomás; Balbinoti, Jean Anacleto; Tiossi, Rodrigo

    2013-10-01

    The purpose of this study was to evaluate the mechanical behavior of two different straight prosthetic abutments (one- and two-piece) for external hex butt-joint connection implants using three-dimensional finite element analysis (3D-FEA). Two 3D-FEA models were designed, one for the two-piece prosthetic abutment (2 mm in height, two-piece mini-conical abutment, Neodent) and another one for the one-piece abutment (2 mm in height, Slim Fit one-piece mini-conical abutment, Neodent), with their corresponding screws and implants (Titamax Ti, 3.75 diameter by 13 mm in length, Neodent). The model simulated the single restoration of a lower premolar using data from a computerized tomography of a mandible. The preload (20 N) after torque application for installation of the abutment and an occlusal loading were simulated. The occlusal load was simulated using average physiological bite force and direction (114.6 N in the axial direction, 17.1 N in the lingual direction and 23.4 N toward the mesial at an angle of 75° to the occlusal plan). The regions with the highest von Mises stress results were at the bottom of the initial two threads of both prosthetic abutments that were tested. The one-piece prosthetic abutment presented a more homogeneous behavior of stress distribution when compared with the two-piece abutment. Under the simulated chewing loads, the von Mises stresses for both tested prosthetic-abutments were within the tensile strength values of the materials analyzed which thus supports the clinical use of both prosthetic abutments.

  16. UV photofunctionalization promotes nano-biomimetic apatite deposition on titanium

    Directory of Open Access Journals (Sweden)

    Saita M

    2016-01-01

    Full Text Available Makiko Saita,1 Takayuki Ikeda,1,2 Masahiro Yamada,1,3 Katsuhiko Kimoto,4 Masaichi Chang-Il Lee,5 Takahiro Ogawa1 1Division of Advanced Prosthodontics, Weintraub Center for Reconstructive Biotechnology, UCLA School of Dentistry, Los Angeles, CA, USA; 2Department of Complete Denture Prosthodontics, Nihon University School of Dentistry, Yokosuka, Japan; 3Division of Molecular and Regenerative Prosthodontics, Tohoku University Graduate School of Dentistry, Sendai, Miyagi, Japan; 4Department of Prosthodontics and Oral Rehabilitation, 5Yokosuka-Shonan Disaster Health Emergency Research Center and ESR Laboratories, Kanagawa Dental University Graduate School of Dentistry, Yokosuka, Japan Background: Although biomimetic apatite coating is a promising way to provide titanium with osteoconductivity, the efficiency and quality of deposition is often poor. Most titanium implants have microscale surface morphology, and an addition of nanoscale features while preserving the micromorphology may provide further biological benefit. Here, we examined the effect of ultraviolet (UV light treatment of titanium, or photofunctionalization, on the efficacy of biomimetic apatite deposition on titanium and its biological capability.Methods and results: Micro-roughed titanium disks were prepared by acid-etching with sulfuric acid. Micro-roughened disks with or without photofunctionalization (20-minute exposure to UV light were immersed in simulated body fluid (SBF for 1 or 5 days. Photofunctionalized titanium disks were superhydrophilic and did not form surface air bubbles when immersed in SBF, whereas non-photofunctionalized disks were hydrophobic and largely covered with air bubbles during immersion. An apatite-related signal was observed by X-ray diffraction on photofunctionalized titanium after 1 day of SBF immersion, which was equivalent to the one observed after 5 days of immersion of control titanium. Scanning electron microscopy revealed nodular apatite deposition

  17. Cadmium Telluride-Titanium Dioxide Nanocomposite for Photodegradation of Organic Substance.

    Science.gov (United States)

    Ontam, Areeporn; Khaorapapong, Nithima; Ogawa, Makoto

    2015-12-01

    Cadmium telluride-titanium dioxide nanocomposite was prepared by hydrothermal reaction of sol-gel derived titanium dioxide and organically modified cadmium telluride. The crystallinity of titanium dioxide in the nanocomposite was higher than that of pure titanium dioxide obtained by the reaction under the same temperature and pressure conditions, showing that cadmium telluride induced the crystallization of titanium dioxide. Diffuse reflectance spectrum of the nanocomposite showed the higher absorption efficiency in the UV-visible region due to band-gap excitation of titanium dioxide. The nanocomposite significantly showed the improvement of photocatalytic activity for 4-chlorophenol with UV light.

  18. Industrial experience with titanium

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, B M; Shoesmith, D W

    1997-09-01

    Titanium is a reference material for the construction of waste containers in the Canadian Nuclear Fuel Waste Management Program. It has been in industrial service for over 30 a, often in severe corrosion environments, but it is still considered a relatively exotic material with limited operating history. This has arisen because of the aerospace applications of this material and the misconception that the high strength-to-weight ratio dominates the choice of this material. In fact, the advantage of titanium lies in its high reliability and excellent corrosion resistance. It has a proven record in seawater heat exchanger service and a demonstrated excellent reliability even in polluted water. For many reasons it is the technically correct choice of material for marine applications. In this report we review the industrial service history of titanium, particularly in hot saline environments, and demonstrate that it is a viable waste container material, based upon this industrial service history and operating experience. (author) 83 refs., 17 tabs., 3 figs.

  19. Industrial experience with titanium

    International Nuclear Information System (INIS)

    Ikeda, B.M.; Shoesmith, D.W.

    1997-09-01

    Titanium is a reference material for the construction of waste containers in the Canadian Nuclear Fuel Waste Management Program. It has been in industrial service for over 30 a, often in severe corrosion environments, but it is still considered a relatively exotic material with limited operating history. This has arisen because of the aerospace applications of this material and the misconception that the high strength-to-weight ratio dominates the choice of this material. In fact, the advantage of titanium lies in its high reliability and excellent corrosion resistance. It has a proven record in seawater heat exchanger service and a demonstrated excellent reliability even in polluted water. For many reasons it is the technically correct choice of material for marine applications. In this report we review the industrial service history of titanium, particularly in hot saline environments, and demonstrate that it is a viable waste container material, based upon this industrial service history and operating experience. (author)

  20. Incremental benefit of 3D transesophageal echocardiography: a case of a mass overlying a prosthetic mitral valve.

    Science.gov (United States)

    Tauras, James M; Zhang, Zhihang; Taub, Cynthia C

    2011-05-01

    A young woman with a mechanical mitral valve and prosthetic mitral stenosis underwent multiple imaging modalities (including transthoracic ECHO, fluoroscopy, and two-dimensional transesophageal ECHO) to determine the cause of her stenosis. Only three-dimensional transesophageal echocardiography demonstrated the full size and extent of an obstructing mass on the strut and sewing ring of the prosthetic mitral valve. © 2011, Wiley Periodicals, Inc.

  1. An Insoluble Titanium-Lead Anode for Sulfate Electrolytes

    Energy Technology Data Exchange (ETDEWEB)

    Ferdman, Alla

    2005-05-11

    The project is devoted to the development of novel insoluble anodes for copper electrowinning and electrolytic manganese dioxide (EMD) production. The anodes are made of titanium-lead composite material produced by techniques of powder metallurgy, compaction of titanium powder, sintering and subsequent lead infiltration. The titanium-lead anode combines beneficial electrochemical behavior of a lead anode with high mechanical properties and corrosion resistance of a titanium anode. In the titanium-lead anode, the titanium stabilizes the lead, preventing it from spalling, and the lead sheathes the titanium, protecting it from passivation. Interconnections between manufacturing process, structure, composition and properties of the titanium-lead composite material were investigated. The material containing 20-30 vol.% of lead had optimal combination of mechanical and electrochemical properties. Optimal process parameters to manufacture the anodes were identified. Prototypes having optimized composition and structure were produced for testing in operating conditions of copper electrowinning and EMD production. Bench-scale, mini-pilot scale and pilot scale tests were performed. The test anodes were of both a plate design and a flow-through cylindrical design. The cylindrical anodes were composed of cylinders containing titanium inner rods and fitting over titanium-lead bushings. The cylindrical design allows the electrolyte to flow through the anode, which enhances diffusion of the electrolyte reactants. The cylindrical anodes demonstrate higher mass transport capabilities and increased electrical efficiency compared to the plate anodes. Copper electrowinning represents the primary target market for the titanium-lead anode. A full-size cylindrical anode performance in copper electrowinning conditions was monitored over a year. The test anode to cathode voltage was stable in the 1.8 to 2.0 volt range. Copper cathode morphology was very smooth and uniform. There was no

  2. Consumer satisfaction with the services of prosthetics and orthotics facilities

    NARCIS (Netherlands)

    Bosmans, Joline; Geertzen, Jan; Dijkstra, Pieter U.

    2009-01-01

    Consumer satisfaction with the services provided in a prosthetics and orthotics (PO) facility has seldom been studied. The aim of this study was to analyze consumer satisfaction regarding the services provided by 15 PO facilities in The Netherlands. Consumers (n=1,364) of these PO facilities who

  3. Apparent culture-negative prosthetic valve endocarditis caused by Peptostreptococcus magnus

    NARCIS (Netherlands)

    van der Vorm, E. R.; Dondorp, A. M.; van Ketel, R. J.; Dankert, J.

    2000-01-01

    In two patients with prosthetic valve endocarditis due to Peptostreptococcus magnus, blood cultures in the BacT/Alert and BACTEC 9240 systems were signal negative. The capability of the BacT/Alert system to detect various Peptostreptococcus species was assessed. P. magnus and P. anaerobius could not

  4. Casting of Titanium and its Alloys

    OpenAIRE

    R. L. Saha; K. T. Jacob

    1986-01-01

    Titaniuni and its alloys have many applications in aerospace, marine and other engineering industries. Titanium requires special melting techniques because of its high reactivity at elevated temperatures and needs special mould materials and methods for castings. This paper reviews the development of titanium casting technology.

  5. Biomedical Titanium alloy prostheses manufacturing by means of Superplastic and Incremental Forming processes

    Directory of Open Access Journals (Sweden)

    Piccininni Antonio

    2016-01-01

    Full Text Available The present work collects some results of the three-years Research Program “BioForming“, funded by the Italian Ministry of Education (MIUR and aimed to investigate the possibility of using flexible sheet forming processes, i.e. Super Plastic Forming (SPF and Single Point Incremental Forming (SPIF, for the manufacturing of patient-oriented titanium prostheses. The prosthetic implants used as case studies were from the skull; in particular, two different Ti alloys and geometries were considered: one to be produced in Ti-Gr23 by SPF and one to be produced in Ti-Gr2 by SPIF. Numerical simulations implementing material behaviours evaluated by characterization tests were conducted in order to design both the manufacturing processes. Subsequently, experimental tests were carried out implementing numerical results in terms of: (i gas pressure profile able to determine a constant (and optimal strain rate during the SPF process; (ii tool path able to avoid rupture during the SPIF process. Post forming characteristics of the prostheses in terms of thickness distributions were measured and compared to data from simulations for validation purposes. A good correlation between numerical and experimental thickness distributions has been obtained; in addition, the possibility of successfully adopting both the SPF and the SPIF processes for the manufacturing of prostheses has been demonstrated.

  6. Long-term release of antibiotics by carbon nanotube-coated titanium alloy surfaces diminish biofilm formation by Staphylococcus epidermidis.

    Science.gov (United States)

    Hirschfeld, Josefine; Akinoglu, Eser M; Wirtz, Dieter C; Hoerauf, Achim; Bekeredjian-Ding, Isabelle; Jepsen, Søren; Haddouti, El-Mustapha; Limmer, Andreas; Giersig, Michael

    2017-05-01

    Bacterial biofilms cause a considerable amount of prosthetic joint infections every year, resulting in morbidity and expensive revision surgery. To address this problem, surface modifications of implant materials such as carbon nanotube (CNT) coatings have been investigated in the past years. CNTs are biologically compatible and can be utilized as drug delivery systems. In this study, multi-walled carbon nanotube (MWCNT) coated TiAl6V4 titanium alloy discs were fabricated and impregnated with Rifampicin, and tested for their ability to prevent biofilm formation over a period of ten days. Agar plate-based assays were employed to assess the antimicrobial activity of these surfaces against Staphylococcus epidermidis. It was shown that vertically aligned MWCNTs were more stable against attrition on rough surfaces than on polished TiAl6V4 surfaces. Discs with coated surfaces caused a significant inhibition of biofilm formation for up to five days. Therefore, MWCNT-modified surfaces may be effective against pathogenic biofilm formation on endoprostheses. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Comparative in vitro biocompatibility of nickel-titanium, pure nickel, pure titanium, and stainless steel: genotoxicity and atomic absorption evaluation.

    Science.gov (United States)

    Assad, M; Lemieux, N; Rivard, C H; Yahia, L H

    1999-01-01

    The genotoxicity level of nickel-titanium (NiTi) was compared to that of its pure constituents, pure nickel (Ni) and pure titanium (Ti) powders, and also to 316L stainless steel (316L SS) as clinical reference material. In order to do so, a dynamic in vitro semiphysiological extraction was performed with all metals using agitation and ISO requirements. Peripheral blood lymphocytes were then cultured in the presence of all material extracts, and their comparative genotoxicity levels were assessed using electron microscopy-in situ end-labeling (EM-ISEL) coupled to immunogold staining. Cellular chromatin exposition to pure Ni and 316L SS demonstrated a significantly stronger gold binding than exposition to NiTi, pure Ti, or the untreated control. In parallel, graphite furnace atomic absorption spectrophotometry (AAS) was also performed on all extraction media. The release of Ni atoms took the following decreasing distribution for the different resulting semiphysiological solutions: pure Ni, 316L SS, NiTi, Ti, and controls. Ti elements were detected after elution of pure titanium only. Both pure titanium and nickel-titanium specimens obtained a relative in vitro biocompatibility. Therefore, this quantitative in vitro study provides optimistic results for the eventual use of nickel-titanium alloys as surgical implant materials.

  8. Method of making self-cleaning skin-like prosthetic polymer surfaces

    Science.gov (United States)

    Simpson, John T.; Ivanov, Ilia N.; Shibata, Jason

    2017-06-06

    An external covering and method of making an external covering for hiding the internal endoskeleton of a mechanical (e.g., prosthetic) device that exhibits skin-like qualities is provided. The external covering generally comprises an internal bulk layer in contact with the endoskeleton of the prosthetic device and an external skin layer disposed about the internal bulk layer. The external skin layer is comprised of a polymer composite with carbon nanotubes embedded therein. The outer surface of the skin layer has multiple cone-shaped projections that provide the external skin layer with superhydrophobicity. The carbon nanotubes are preferably vertically aligned between the inner surface and outer surface of the external skin layer in order to provide the skin layer with the ability to transmit heat. Superhydrophobic powders may optionally be used as part of the polymer composite or applied as a coating to the surface of the skin layer to enhance superhydrophobicity.

  9. International normalized ratio self-management lowers the risk of thromboembolic events after prosthetic heart valve replacement.

    Science.gov (United States)

    Eitz, Thomas; Schenk, Soren; Fritzsche, Dirk; Bairaktaris, Andreas; Wagner, Otto; Koertke, Heinrich; Koerfer, Reiner

    2008-03-01

    Although prosthetic valves are durable and easy to implant, the need for lifetime warfarin-based anticoagulation restricts their exclusive usage. We investigated if anticoagulation self-management improves outcome in a single-center series. Between 1994 and 1998, 765 patients with prosthetic valve replacements were prospectively enrolled and randomized to receive conventional anticoagulation management by their primary physician (group 1, n = 295) or to pursue anticoagulation self-management (group 2, n = 470). A study head office was implemented to coordinate and monitor anticoagulation protocols, international normalized ratios (INR), and adverse events. Patients were instructed on how to obtain and test their own blood samples and to adjust warfarin dosages according to the measured INR (target range, 2.5 to 4). Mean INR values were slightly yet significantly smaller in group 1 than in group 2 (2.8 +/- 0.7 vs 3.0 +/- .6, p events were similar in both groups. Time-related multivariate analysis identified INR self-management and higher INR as independent predictors for better outcome. Anticoagulation self-management can improve INR profiles up to 2 years after prosthetic valve replacement and reduce adverse events. Current indications of prosthetic rather than biologic valve implantations may be extended if the benefit of INR self-management is shown by future studies with longer follow-up.

  10. Microbiological Aetiology, Epidemiology, and Clinical Profile of Prosthetic Joint Infections: Are Current Antibiotic Prophylaxis Guidelines Effective?

    Science.gov (United States)

    Cheng, Allen C.; Buising, Kirsty L.; Choong, Peter F. M.

    2012-01-01

    Prosthetic joint infections remain a major complication of arthroplasty. At present, local and international guidelines recommend cefazolin as a surgical antibiotic prophylaxis at the time of arthroplasty. This retrospective cohort study conducted across 10 hospitals over a 3-year period (January 2006 to December 2008) investigated the epidemiology and microbiological etiology of prosthetic joint infections. There were 163 cases of prosthetic joint infection identified. From a review of the microbiological culture results, methicillin-resistant Staphylococcus aureus (MRSA) and coagulase-negative staphylococci were isolated in 45% of infections. In addition, polymicrobial infections, particularly those involving Gram-negative bacilli and enterococcal species, were common (36%). The majority (88%) of patients received cefazolin as an antibiotic prophylaxis at the time of arthroplasty. In 63% of patients in this cohort, the microorganisms subsequently obtained were not susceptible to the antibiotic prophylaxis administered. The results of this study highlight the importance of ongoing reviews of the local ecology of prosthetic joint infection, demonstrating that the spectrum of pathogens involved is broad. The results should inform empirical antibiotic therapy. This report also provokes discussion about infection control strategies, including changing surgical antibiotic prophylaxis to a combination of glycopeptide and cefazolin, to reduce the incidence of infections due to methicillin-resistant staphylococci. PMID:22314530

  11. Effects of alignment on the roll-over shapes of prosthetic feet.

    Science.gov (United States)

    Hansen, Andrew

    2008-12-01

    Recent work suggests that a prosthetic ankle-foot component's roll-over shape - the effective rocker it conforms to between initial contact and opposite initial contact (the 'roll-over' interval of walking) - is closely linked to its final alignment in the prosthesis (as determined by a skilled prosthetist using heuristic techniques). If true, this information may help to determine the appropriate alignment for a lower limb prosthesis before it is built, or a priori. Knowledge is needed for future models that will incorporate the roll-over shape including the relative effect of alignment on the roll-over shape's radius of curvature and arc length. The purpose of this study was to evaluate the hypotheses that: (i) Changes in prosthesis alignment alter the position and orientation of a foot's roll-over shape in prosthesis-based coordinates, and (ii) these changes occur without changing the radius of curvature or arc length of the roll-over shape. To examine the hypotheses, this study examined the effects of nine alignment settings on the roll-over shapes of two prosthetic feet. The idea that alignment changes move and rotate roll-over shapes of prosthetic feet in prosthesis coordinates is supported by this work, but the hypothesis that the radius of curvature and arc length do not change for different alignments is not strongly supported by the data. A revised approach is presented that explains some of the changes to the roll-over shape parameters due to changes in rotational alignment.

  12. FDG-PET for diagnosing prosthetic joint infection: systematic review and metaanalysis

    Energy Technology Data Exchange (ETDEWEB)

    Kwee, Thomas C. [University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Kwee, Robert M. [University Medical Center Maastricht, Department of Radiology, Maastricht (Netherlands); Alavi, Abass [Hospital of the University of Pennsylvania, Division of Nuclear Medicine, Philadelphia, PA (United States)

    2008-11-15

    The aim of this study was to systematically review and metaanalyze published data on the diagnostic performance of {sup 18}F-fluoro-2-deoxyglucose positron emission tomography (FDG-PET) in detecting prosthetic hip or knee joint infection. A systematic search for relevant studies was performed of the PubMed/MEDLINE and Embase databases. Two reviewers independently assessed the methodological quality of each study. A metaanalysis of the reported sensitivity and specificity of each study was performed. Subgroup analyses were performed if results of individual studies were heterogeneous. The inclusion criteria were met by 11 studies; there was a total sample size of 635 prostheses. Overall, the studies had good methodological quality. Pooled sensitivity and specificity of FDG-PET for the detection of prosthetic hip or knee joint infection were 82.1% (95%CI = 68.0-90.8%) and 86.6% (95%CI = 79.7-91.4%), respectively. Heterogeneity among the results of individual studies was present (I {sup 2} = 68.8%). Diagnostic performance was influenced by type of joint prostheses (hip prostheses vs. knee prostheses) and type of reconstruction method used (filtered back vs. iterative) (p = 0.0164 and p = 0.0235, respectively). In this metaanalysis, overall diagnostic performance of FDG-PET was moderate to high. Caution is warranted, however, because results of individual studies were heterogeneous and could not be fully explored. Future studies should further explore potential causes of heterogeneity and validate the use of FDG-PET for diagnosing prosthetic joint infection. (orig.)

  13. FDG-PET for diagnosing prosthetic joint infection: systematic review and metaanalysis

    International Nuclear Information System (INIS)

    Kwee, Thomas C.; Kwee, Robert M.; Alavi, Abass

    2008-01-01

    The aim of this study was to systematically review and metaanalyze published data on the diagnostic performance of 18 F-fluoro-2-deoxyglucose positron emission tomography (FDG-PET) in detecting prosthetic hip or knee joint infection. A systematic search for relevant studies was performed of the PubMed/MEDLINE and Embase databases. Two reviewers independently assessed the methodological quality of each study. A metaanalysis of the reported sensitivity and specificity of each study was performed. Subgroup analyses were performed if results of individual studies were heterogeneous. The inclusion criteria were met by 11 studies; there was a total sample size of 635 prostheses. Overall, the studies had good methodological quality. Pooled sensitivity and specificity of FDG-PET for the detection of prosthetic hip or knee joint infection were 82.1% (95%CI = 68.0-90.8%) and 86.6% (95%CI = 79.7-91.4%), respectively. Heterogeneity among the results of individual studies was present (I 2 = 68.8%). Diagnostic performance was influenced by type of joint prostheses (hip prostheses vs. knee prostheses) and type of reconstruction method used (filtered back vs. iterative) (p = 0.0164 and p = 0.0235, respectively). In this metaanalysis, overall diagnostic performance of FDG-PET was moderate to high. Caution is warranted, however, because results of individual studies were heterogeneous and could not be fully explored. Future studies should further explore potential causes of heterogeneity and validate the use of FDG-PET for diagnosing prosthetic joint infection. (orig.)

  14. Manufacturing techniques for titanium aluminide based alloys and metal matrix composites

    Science.gov (United States)

    Kothari, Kunal B.

    Dual phase titanium aluminides composed vastly of gamma phase (TiAl) with moderate amount of alpha2 phase (Ti3Al) have been considered for several high temperature aerospace and automobile applications. High specific strength coupled with good high temperature performance in the areas of creep and oxidation resistance makes titanium aluminides "materials of choice" for next generation propulsion systems. Titanium alumnides are primarily being considered as potential replacements for Ni-based superalloys in gas turbine engine components with aim of developing more efficient and leaner engines exhibiting high thrust-to-weight ratio. Thermo-mechanical treatments have shown to enhance the mechanical performance of titanium aluminides. Additionally, small additions of interstitial elements have shown further and significant improvement in the mechanical performance of titanium alumnide alloys. However, titanium aluminides lack considerably in room temperature ductility and as a result manufacturing processes of these aluminides have greatly suffered. Traditional ingot metallurgy and investment casting based methods to produce titanium aluminide parts in addition to being expensive, have also been unsuccessful in producing titanium aluminides with the desired mechanical properties. Hence, the manufacturing costs associated with these methods have completely outweighed the benefits offered by titanium aluminides. Over the last two decades, several powder metallurgy based manufacturing techniques have been studied to produce titanium aluminide parts. These techniques have been successful in producing titanium aluminide parts with a homogeneous and refined microstructure. These powder metallurgy techniques also hold the potential of significant cost reduction depending on the wide market acceptance of titanium aluminides. In the present study, a powder metallurgy based rapid consolidation technique has been used to produce near-net shape parts of titanium aluminides. Micron

  15. Preparation of titanium diboride powders from titanium alkoxide and ...

    Indian Academy of Sciences (India)

    Administrator

    Department of Materials and Manufacturing Process, Malek Ashtar University of Technology, Tehran. 15875-1744, Iran ... Titanium diboride is a hard refractory material with a high melting point ... (λ = 1⋅540598 Å) radiation. Morphology of the ...

  16. EFFECT OF POLYMER PROSTHETIC CONSTRUCTION TREATED WITH GLOW-DISCHARGE PLASMA ON ORAL MUCOSA (CLINICAL CASE

    Directory of Open Access Journals (Sweden)

    E. O. Kudasova

    2017-01-01

    Full Text Available Prosthetic material should induce minimal pathological reaction when in contact with the oral mucosa, especially during oral rehabilitation of patients with tumors of the oral mucosa. The article presents monitoring of a patient after surgery for cancer of the buccal mucosa at the stage of orthopedic rehabilitation. Treatment plan proposed complex oral rehabilitation. A maxillary complete removable denture was manufactured as well as metalloceramic and partial mandibular dentures. Plasma chemical modification of the removable dentures was planned after correction of the prosthetics and primary adaptation. Removable dentures were applied at the maxilla and mandibula. Per our recommendations, the patient was examined weekly for a month and monthly for 6 months. No new tumors or pathological elements were observed.Conclusions. Changes in critical surface tension of the removable dentures made of acrylic plastic improve their biological characteristics as demonstrated by positive clinical dynamics. Prosthetic constructions with hydrophilic surface are recommended in complex clinical cases when patients with tumors of the oral mucosa require dentures.

  17. The efficacy of the Ankle Mimicking Prosthetic Foot prototype 4.0 during walking: Physiological determinants.

    Science.gov (United States)

    De Pauw, Kevin; Cherelle, Pierre; Roelands, Bart; Lefeber, Dirk; Meeusen, Romain

    2018-04-01

    Evaluating the effectiveness of a novel prosthetic device during walking is an important step in product development. To investigate the efficacy of a novel quasi-passive ankle prosthetic device, Ankle Mimicking Prosthetic Foot 4.0, during walking at different speeds, using physiological determinants in transtibial and transfemoral amputees. Nonrandomized crossover design for amputees. Six able-bodied subjects, six unilateral transtibial amputees, and six unilateral transfemoral amputees underwent a 6-min walk test at normal speed, followed by series of 2-min walking at slow, normal, and fast speeds. The intensity of effort and subjective measures were determined. Amputees performed all walking tests on a treadmill with current and novel prostheses. Shapiro-Wilk normality tests and parametric and nonparametric tests were conducted (p 4.0 is a novel quasi-passive ankle prosthesis with state-of-the-art technological parts. Subjective measures show the importance of this technology, but the intensity of effort during walking still remains higher compared to current passive prostheses, especially in transfemoral amputees.

  18. Lunar-derived titanium alloys for hydrogen storage

    Science.gov (United States)

    Love, S.; Hertzberg, A.; Woodcock, G.

    1992-01-01

    Hydrogen gas, which plays an important role in many projected lunar power systems and industrial processes, can be stored in metallic titanium and in certain titanium alloys as an interstitial hydride compound. Storing and retrieving hydrogen with titanium-iron alloy requires substantially less energy investment than storage by liquefaction. Metal hydride storage systems can be designed to operate at a wide range of temperatures and pressures. A few such systems have been developed for terrestrial applications. A drawback of metal hydride storage for lunar applications is the system's large mass per mole of hydrogen stored, which rules out transporting it from earth. The transportation problem can be solved by using native lunar materials, which are rich in titanium and iron.

  19. Welding of Prosthetic Alloys / Spawanie Stopów Protetycznych Typu Co-Cr

    Directory of Open Access Journals (Sweden)

    Wojciechowska M.

    2015-12-01

    Full Text Available This paper presents the techniques of joining metal denture elements, used in prosthetic dentistry: the traditional soldering technique with a gas burner and a new technique of welding with a laser beam; the aim of the study was to make a comparative assessment of the quality of the joints in view of the possibility of applying them in prosthetic structures. Fractographic examinations were conducted along with tensile strength and impact strength tests, and the quality of the joints was assessed compared to the solid metal. The experiments have shown that the metal elements used to make dentures, joined by the technique which employs a laser beam, have better strength properties than those achieved with a gas burner.

  20. In vitro activity of ceftaroline against staphylococci from prosthetic joint infection.

    Science.gov (United States)

    Park, Kyung-Hwa; Greenwood-Quaintance, Kerryl E; Patel, Robin

    2016-02-01

    We tested the in vitro activity of ceftaroline by Etest against staphylococci recovered from patients with prosthetic joint infection, including 97 Staphylococcus aureus isolates (36%, oxacillin resistant) and 74 Staphylococcus epidermidis isolates (74%, oxacillin resistant). Ceftaroline inhibited all staphylococci at ≤0.5 μg/mL. The ceftaroline MIC(90/50) values for methicillin-susceptible S. aureus, methicillin-susceptible S. epidermidis, methicillin-resistant S. aureus, and methicillin-resistant S. epidermidis were 0.19/0.125, 0.094/0.047, 0.5/0.38, and 0.38/0.19 μg/mL, respectively. Based on these in vitro findings, ceftaroline should be further evaluated as a potential therapeutic option for the treatment of prosthetic joint infection caused by methicillin-susceptible and methicillin-resistant S. aureus and S. epidermidis. Copyright © 2016 Elsevier Inc. All rights reserved.