WorldWideScience

Sample records for excess air operations

  1. The effects of air stoichiometry and air excess ratio on the transient response of a PEMFC under load change conditions

    International Nuclear Information System (INIS)

    Kim, Bosung; Cha, Dowon; Kim, Yongchan

    2015-01-01

    Highlights: • Effects of controlling parameters on the transient response of a PEMFC are studied. • The transient response is measured by varying air stoichiometry and air excess ratio. • Voltage drop, undershoot, and voltage fluctuation are analyzed under the load change. • Optimal air stoichiometry and air excess ratio are suggested for stable operation. - Abstract: The transient response of a proton exchange membrane fuel cell (PEMFC) is an important issue for transportation applications. The objective of this study is to investigate the effects of operating and controlling parameters on the transient response of a PEMFC for achieving more stable cell performance under load change conditions. The transient response of a PEMFC was measured and analyzed by varying air stoichiometry, air humidity, and air excess ratio (AER). The optimal air stoichiometry and AER were determined to minimize the voltage drop, undershoot, and voltage fluctuation under the load change, while maintaining high cell performance. Based on the present data, the optimal air stoichiometry was determined to be between 2.0 and 2.5, and the optimal AER was suggested to be between 1.65 and 2.0

  2. Methodology to determine the appropriate amount of excess air for the operation of a gas turbine in a wet environment

    Energy Technology Data Exchange (ETDEWEB)

    Lugo-Leyte, R.; Zamora-Mata, J.M.; Torres-Aldaco, A. [Universidad Autonoma Metropolitana-Iztapalapa, Departamento de Ingenieria de Procesos e Hidraulica, San Rafael Atlixco 186, Col Vicentina 09340, Iztapalapa, Mexico, D.F. (Mexico); Toledo-Velazquez, M. [Instituto Politecnico Nacional, Escuela Superior de Ingenieria Mecanica y Electrica, Seccion de Estudios de Posgrado e Investigacion, Laboratorio de Ingenieria Termica e Hidraulica Aplicada, Unidad Profesional Adolfo Lopez Mateos, Edificio 5, 3er piso SEPI-ESIME, C.P. 07738, Col. Lindavista, Mexico D.F. (Mexico); Salazar-Pereyra, M. [Tecnologico de Estudios Superiores de Ecatepec, Division de Ingenieria Mecatronica e Industrial, Posgrado en Ciencias en Ingenieria Mecatronica, Av. Tecnologico s/n, Col. Valle de Anahuac, C.P. 55210, Ecatepec de Morelos, Estado de Mexico (Mexico)

    2010-02-15

    This paper addresses the impact of excess air on turbine inlet temperature, power, and thermal efficiency at different pressure ratios. An explicit relationship is developed to determine the turbine inlet temperature as a function of excess air, pressure ratio and relative humidity. The effect of humidity on the calculation of excess air to achieve a pre-established power output is analyzed and presented. Likewise it is demonstrated that dry air calculations provide a valid upper bound for the performance of a gas turbine under a wet environment. (author)

  3. Hanford Site air operating permit application

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-05-01

    The Clean Air Act Amendments of 1990, which amended the Federal Clean Air Act of 1977, required that the US Environmental Protection Agency develop a national Air Operating Permit Program, which in turn would require each state to develop an Air Operating Permit Program to identify all sources of ``regulated`` pollutants. Regulated pollutants include ``criteria`` pollutants (oxides of nitrogen, sulfur oxides, total suspended particulates, carbon monoxide, particulate matter greater than 10 micron, lead) plus 189 other ``Hazardous`` Air Pollutants. The Hanford Site, owned by the US Government and operated by the US Department of Energy, Richland Operations Office, is located in southcentral Washington State and covers 560 square miles of semi-arid shrub and grasslands located just north of the confluence of the Snake and Yakima Rivers with the Columbia River. This land, with restricted public access, provides a buffer for the smaller areas historically used for the production of nuclear materials, waste storage, and waste disposal. About 6 percent of the land area has been disturbed and is actively used. The Hanford Site Air Operating Permit Application consists of more than 1,100 sources and in excess of 300 emission points. Before January 1995, the maintenance and operations contractor and the environmental restoration contractor for the US Department of Energy completed an air emission inventory on the Hanford Site. The inventory has been entered into a database so that the sources and emission points can be tracked and updated information readily can be retrieved. The Hanford Site Air Operating Permit Application contains information current as of April 19, 1995.

  4. Hanford Site air operating permit application

    International Nuclear Information System (INIS)

    1995-05-01

    The Clean Air Act Amendments of 1990, which amended the Federal Clean Air Act of 1977, required that the US Environmental Protection Agency develop a national Air Operating Permit Program, which in turn would require each state to develop an Air Operating Permit Program to identify all sources of ''regulated'' pollutants. Regulated pollutants include ''criteria'' pollutants (oxides of nitrogen, sulfur oxides, total suspended particulates, carbon monoxide, particulate matter greater than 10 micron, lead) plus 189 other ''Hazardous'' Air Pollutants. The Hanford Site, owned by the US Government and operated by the US Department of Energy, Richland Operations Office, is located in southcentral Washington State and covers 560 square miles of semi-arid shrub and grasslands located just north of the confluence of the Snake and Yakima Rivers with the Columbia River. This land, with restricted public access, provides a buffer for the smaller areas historically used for the production of nuclear materials, waste storage, and waste disposal. About 6 percent of the land area has been disturbed and is actively used. The Hanford Site Air Operating Permit Application consists of more than 1,100 sources and in excess of 300 emission points. Before January 1995, the maintenance and operations contractor and the environmental restoration contractor for the US Department of Energy completed an air emission inventory on the Hanford Site. The inventory has been entered into a database so that the sources and emission points can be tracked and updated information readily can be retrieved. The Hanford Site Air Operating Permit Application contains information current as of April 19, 1995

  5. Excess air in groundwater as a potential indicator of past environmental changes

    International Nuclear Information System (INIS)

    Aeschenbach-Hertig, W.; Beyerle, U.; Holocher, J.; Peeters, F.; Kipfer, R.

    2002-01-01

    Dissolved noble gases in groundwater are used to reconstruct paleotemperature, but also yield information about 'excess air', a component of dissolved gases in excess of solubility equilibrium, derived from dissolution of trapped air in the ground. A good characterization of the excess air component is necessary not only to obtain reliable noble gas temperatures, but also to investigate the potential of excess air as a proxy for past environmental conditions. Two excess air related quantities can be derived from groundwater noble gas data sets: The initial air/water ratio and the pressure exerted on the entrapped air. Under recharge conditions typical for many aquifers, the excess of dissolved gases, expressed by the relative Ne excess ΔNe, is mainly determined by the hydrostatic pressure on the entrapped air. Thus, we suggest that ΔNe is essentially a measure of the amplitude of water table fluctuations in the recharge area. Comparing data sets from three aquifers in temperate, humid latitudes and three aquifers in tropical, semi-arid regions, we find that ΔNe is generally higher in the tropical aquifers, possibly related to larger water table fluctuations in these aquifers characterized by deep unsaturated zones. Whereas ΔNe shows little temporal variation in the mid-latitude aquifers, there is a strong signal of higher ΔNe in the paleowaters of the tropical aquifers as compared to water recharged under modern climate conditions. This finding may indicate a higher variability of recharge in the past at the studied tropical sites. (author)

  6. Brazilian air traffic controllers exhibit excessive sleepiness.

    Science.gov (United States)

    Ribas, Valdenilson Ribeiro; de Almeida, Cláudia Ângela Vilela; Martins, Hugo André de Lima; Alves, Carlos Frederico de Oliveira; Alves, Marcos José Pinheiro Cândido; Carneiro, Severino Marcos de Oliveira; Ribas, Valéria Ribeiro; de Vasconcelos, Carlos Augusto Carvalho; Sougey, Everton Botelho; de Castro, Raul Manhães

    2011-01-01

    Excessive sleepiness (ES) is an increased tendency to initiate involuntary sleep for naps at inappropriate times. The objective of this study was to assess ES in air traffic controllers (ATCo). 45 flight protection professionals were evaluated, comprising 30 ATCo, subdivided into ATCo with ten or more years in the profession (ATCo≥10, n=15) and ATCo with less than ten years in the profession (ATCoair traffic controllers exhibit excessive sleepiness.

  7. Effects of an alternating work shift on air traffic controllers and the relationship with excessive daytime sleepiness and stress.

    Science.gov (United States)

    Freitas, Ângela M; Portuguez, Mirna Wetters; Russomano, Thaís; Freitas, Marcos de; Silvello, Silvio Luis da Silva; Costa, Jaderson Costa da

    2017-10-01

    To evaluate symptoms of stress and excessive daytime sleepiness (EDS) in air traffic control (ATC) officers in Brazil. Fifty-two ATC officers participated, based at three air traffic control units, identified as A, B and C. Stress symptoms were assessed using the Lipp Inventory of Stress Symptoms for Adults, and EDS by the Epworth Sleepiness Scale. The sample mean age was 37 years, 76.9% of whom were male. Excessive daytime sleepiness was identified in 25% of the ATC officers, with 84.6% of these based at air traffic control unit A, which has greater air traffic flow, operating a 24-hour alternating work shift schedule. A total of 16% of the ATC officers had stress symptoms, and of these, 62% showed a predominance of physical symptoms. The high percentage of ATC officers with EDS identified in group A may be related to chronodisruption due to night work and alternating shifts.

  8. Field experiment on excess air formation in the riverbank of Danube

    International Nuclear Information System (INIS)

    Palcsu, L.; Major, Z.; Aeschbach-Hertig, W.

    2007-01-01

    Complete text of publication follows. Excess air is a contribution to the gases dissolved in groundwater in addition to the solubility equilibrium component, formed by partial or total dissolution of air trapped during water level rises in the unsaturated zone. The amount of excess air can be quite large, mainly if the water level increase is significant. The first aim of this field experiment carried out in September 2007 during a flood (Fig. 1/b) occurred along the Danube River has been to demonstrate that the excess air formation can be detected and studied under natural conditions when the groundwater level is rising. The study site is located in the riverbank of Danube River, the dug-well is at around 30 m from the riverbed (Fig. 1/a). The whole area is composed of fluvial sand. Separated water samples can be taken from the sampling tubes. Each sampling tube represents a certain depth. The horizontal groundwater flow velocity is supposed to be around 10 m/day (or at least this magnitude), that of course depends on the level difference between Danube and the groundwater. Helium and neon concentrations have been measured from the water samples. What we can see from these noble gas data is a probable correlation between groundwater level and excess noble gas concentrations. He and Ne are correlating providing evidence that the excess components are of same origin. However, the helium excess is usually larger than that of neon that means there has to be non atmospheric components of helium, such as terrigenic and tritiogenic. The R/Ra ratios are generally higher than one clearly showing tritiogenic 3 He in the water. Having a look at Fig. 1/b-c, it can be observed that there is a relatively good relation between groundwater rising and the excesses of the noble gases. From this sampling campaign, we can conclude that this kind of field experiment does make sense. Further noble gases have to be measured, and more information has to be gained regarding to the local

  9. Flood-controlled excess-air formation favors aerobic respiration and limits denitrification activity in riparian groundwater

    Directory of Open Access Journals (Sweden)

    Simone ePeter

    2015-11-01

    Full Text Available The saturated riparian zones of rivers act as spatially and temporally variable biogeochemical reactors. This complicates the assessment of biogeochemical transport and transformation processes. During a flood event, excess-air formation, i.e. the inclusion and dissolution of air bubbles into groundwater, can introduce high amounts of dissolved O2 and thereby affect biogeochemical processes in groundwater. With the help of a field-installed membrane-inlet mass-spectrometer we resolved the effects of flood induced excess-air formationon organic carbon and nitrogen transformations in groundwater of different riparian zones of a restored section of the River Thur, Switzerland. The results show that the flood event triggered high aerobic respiration activity in the groundwater below a zone densely populated with willow plants. The flood introduced high concentrations of O2 (230 µmol L–1 to the groundwater through the formation of excess air and transported up to ~400 µmol L 1 organic carbon from the soil/root layer into groundwater during the movement of the water table. A rapid respiration process, quantified via the measurements of O2, CO2 and noble-gas concentrations, led to fast depletion of the introduced O2 and organic carbon and to high CO2 concentration (590 µmol L–1 in the groundwater shortly after the flood. The synchronous analysis of different nitrogen species allowed studying the importance of denitrification activity. The results indicate that in the willow zone excess-air formation inhibited denitrification through high O2 concentration input. Instead, the observed decrease in nitrate concentration (~50 µmol N L 1 may be related to fostered nitrate uptake by plants. In the other riparian zones closer to the river, no significant excess-air formation and corresponding respiration activity was observed. Overall, analyzing the dissolved gases in the groundwater significantly contributed to deciphering biogeochemical processes in

  10. Royal Danish Air Force. Air Operations Doctrine

    DEFF Research Database (Denmark)

    Nørby, Søren

    This brief examines the development of the first Danish Air Force Air Operations Doctrine, which was officially commissioned in October 1997 and remained in effect until 2010. The development of a Danish air power doctrine was heavily influenced by the work of Colonel John Warden (USAF), both...... through his book ”The Air Campaign” and his subsequent planning of the air campaign against Iraq in 1990-1991. Warden’s ideas came to Denmark and the Danish Air Force by way of Danish Air Force students attending the United States Air Force Air University in Alabama, USA. Back in Denmark, graduates from...... the Air University inspired a small number of passionate airmen, who then wrote the Danish Air Operations Doctrine. The process was supported by the Air Force Tactical Command, which found that the work dovetailed perfectly with the transformation process that the Danish Air Force was in the midst...

  11. Operation of transition-edge sensors with excess thermal noise

    International Nuclear Information System (INIS)

    Maasilta, I J; Kinnunen, K M; Nuottajaervi, A K; Leppaeniemi, J; Luukanen, A

    2006-01-01

    The superconducting transition-edge sensor (TES) is currently one of the most attractive choices for ultra-high resolution calorimetry in the keV x-ray band, and is being considered for future ESA and NASA missions. We have performed a study on the noise characteristics of Au/Ti bilayer TESs, at operating temperatures around ∼100 mK, with the SQUID readout at 1.5 K. Experimental results indicate that without modifications the back-action noise from the SQUID chip degrades the noise characteristics significantly. We present a simple and effective solution to the problem: by installing an extra shunt resistor which absorbs the excess radiation from the SQUID input, we have reduced the excess thermal (photon) noise power down by approximately a factor of five, allowing high resolution operation of the sensors

  12. Optimization of recirculating laminar air flow in operating room air conditioning systems

    Directory of Open Access Journals (Sweden)

    Enver Yalcin

    2016-04-01

    Full Text Available The laminar flow air-conditioning system with 100% fresh air is used in almost all operating rooms without discrimination in Turkey. The laminar flow device which is working with 100% fresh air should be absolutely used in Type 1A operating rooms. However, there is not mandatory to use of 100% fresh air for Type 1B defined as places performed simpler operation. Compared with recirculating laminar flow, energy needs of the laminar flow with 100 % fresh air has been emerged about 40% more than re-circulated air flow. Therefore, when a recirculating laminar flow device is operated instead of laminar flow system with 100% fresh air in the Type 1B operating room, annual energy consumption will be reduced. In this study, in an operating room with recirculating laminar flow, optimal conditions have been investigated in order to obtain laminar flow form by analyzing velocity distributions at various supply velocities by using computational fluid dynamics method (CFD.

  13. Air quality on biomass harvesting operations

    Science.gov (United States)

    Dana Mitchell

    2011-01-01

    The working environment around logging operations can be very dusty. But, air quality around logging operations is not well documented. Equipment movements and trafficking on the landing can cause dust to rise into the air. The addition of a biomass chipper creates different air flow patterns and may stir up additional dust. This project addresses two topics related to...

  14. Compressed air energy storage system

    Science.gov (United States)

    Ahrens, Frederick W.; Kartsounes, George T.

    1981-01-01

    An internal combustion reciprocating engine is operable as a compressor during slack demand periods utilizing excess power from a power grid to charge air into an air storage reservoir and as an expander during peak demand periods to feed power into the power grid utilizing air obtained from the air storage reservoir together with combustible fuel. Preferably the internal combustion reciprocating engine is operated at high pressure and a low pressure turbine and compressor are also employed for air compression and power generation.

  15. Environmental control implications of generating electric power from coal. 1977 technology status report. Appendix D. Assessment of NO/sub x/ control technology for coal fired utility boilers. [Low-excess-air, staged combustion, flu gas recirculation and burner design

    Energy Technology Data Exchange (ETDEWEB)

    1977-12-01

    An NOx control technology assessment study was conducted to examine the effectiveness of low-excess-air firing, staged combustion, flue gas recirculation, and current burner/boiler designs as applied to coal-fired utility boilers. Significant variations in NOx emissions exist with boiler type, firing method, and coal type, but a relative comparison of emissions control performance, cost, and operational considerations is presented for each method. The study emphasized the numerous operational factors that are of major importance to the user in selecting and implementing a combustion modification technique. Staged combustion and low-excess-air operation were identified as the most cost-effective methods for existing units. Close control of local air/fuel ratios and rigorous combustion equipment maintenance are essential to the success of both methods. Flue gas recirculation is relatively ineffective and has the added concern of tube erosion. More research is needed to resolve potential corrosion concerns with low-NOx operating modes. Low-NOx burners in conjunction with a compartmentalized windbox are capable of meeting a 0.6-lb/million Btu emission level on new units. Advanced burner designs are being developed to meet research emission goals of approximately 0.25 lb/MBtu.

  16. [Microbial air purity in hospitals. Operating theatres with air conditioning system].

    Science.gov (United States)

    Krogulski, Adam; Szczotko, Maciej

    2010-01-01

    The aim of this study was to show the influence of air conditioning control for microbial contamination of air inside the operating theatres equipped with correctly working air-conditioning system. This work was based on the results of bacteria and fungi concentration in hospital air obtained since 2001. Assays of microbial air purity conducted on atmospheric air in parallel with indoor air demonstrated that air filters applied in air-conditioning systems worked correctly in every case. To show the problem of fluctuation of bacteria concentration more precisely, every sequences of single results from successive measure series were examined independently.

  17. Operational test procedure for Bldg 241-A-701 air compressor

    International Nuclear Information System (INIS)

    Desantis, G.N.

    1995-01-01

    This document is an Operability Test Procedure (OTP) which will verify and record that the 241-A-701 air compressor and associated equipment operates within their intended design parameters. The activities defined in this OTP will be performed to ensure the daily operation of the new compressed air system can be reliable and efficient. The Compressed Air System (CAS) for 241-A-701 supplies process and instrument air to the A, AX, AY, and AZ tank farms. The primary use of the CAS is for tank farms instrumentation, air operated valves, and air lift circulators

  18. Operation technology of air treatment system in nuclear facilities

    CERN Document Server

    Chun, Y B; Hwong, Y H; Lee, H K; Min, D K; Park, K J; Uom, S H; Yang, S Y

    2001-01-01

    Effective operation techniques were reviewed on the air treatment system to protect the personnel in nuclear facilities from the contamination of radio-active particles and to keep the environment clear. Nuclear air treatment system consisted of the ventilation and filtering system was characterized by some test. Measurement of air velocity of blowing/exhaust fan in the ventilation system, leak tests of HEPA filters in the filtering, and measurement of pressure difference between the areas defined by radiation level were conducted. The results acquired form the measurements were reflected directly for the operation of air treatment. In the abnormal state of virus parts of devices composted of the system, the repairing method, maintenance and performance test were also employed in operating effectively the air treatment system. These measuring results and techniques can be available to the operation of air treatment system of PIEF as well as the other nuclear facilities in KAERI.

  19. Operational air sampling report, July--December 1991

    International Nuclear Information System (INIS)

    Lyons, C.L.

    1992-11-01

    Air sampling is one of the more useful ways of assessing the effectiveness of operational radiation safety programs at the Nevada Test Site (NTS). Air sampling programs document NTS airborne radionuclide concentrations in various work locations and environments. These concentrations generally remain well below the Derived Air Concentration (DAC) values prescribed by the Department of Energy (DOE 5480.11, Attachment 1) or the Derived Concentration Guide (DCG) values prescribed by the Department of Energy DOE 5400.5, Chapter Ill. The Defense Nuclear Agency (DNA) tunnel complexes, Area 12 Test Support Compound and the Area 6 Decontamination Pad and Laundry air sampling programs are summarized in this report. Evaluations are based on Analytical Services Department (ASD) Counting Laboratory analyses and Health Protection Department (HPD)/Radiological Field Operations Section (RFOS) radiation protection technician's (RPT) or health physicists' calculations for air samples collected July 1 through December 31, 1991. Of the NTS operational air sampling programs in the tunnel complexes, the initial mining and event reentry and recovery operations represent the only real airborne radioactive inhalation potentials to personnel. Monthly filter and scintillation cell samples were taken and counted in RDA-200 Radon Detectors to document working levels of radon/thoron daughters and picocurie/liter (PCVL) concentrations of radon gas. Weekly Drierite samples for tritium analysis were taken in the active tunnel complexes to document any changes in normal background levels or reentry drifts as they are advanced toward ground zero (GZ) areas. Underground water sources are considered primary transporters of tritium from old event areas

  20. Air Pollution Potential from Electroplating Operations.

    Science.gov (United States)

    Diamond, Philip

    Measurements were made of emission rates from electroplating operations considered to have maximum air pollution potential. Sampling was performed at McClellan and additional data from a previous survey at Hill Air Force Base was used. Values obtained were extremely low. Based on existing Federal standards, no collectors are specifically required…

  1. OPERATIONAL RESTRICTIONS FOR REDUCING NOISE AND THE SAFETY OF AIR OPERATIONS

    Directory of Open Access Journals (Sweden)

    Anna KWASIBORSKA

    2017-03-01

    Full Text Available Many European airports are located in close proximity to residential or protected areas. Aircraft noise emissions caused by the landing and taking off of aircraft are a big problem in these areas. From an operational point of view, the method for reducing noise is to reduce traffic volume or change its organization, especially during the night. Some procedures and tools have been developed to support air traffic management in the implementation of operational constraints necessary to maintain noise at an acceptable level. The objective of this paper is to analyse the effectiveness of these tools. For this purpose, we have analysed existing methods of operational noise reduction, taking into account their influence on the structure, smoothness, punctuality and, especially, the safety of air traffic. As a result, existing risks have been identified, while methods have been proposed to combine two important air traffic service tasks: ensuring safety, while taking into account the environmental constraints, especially in relation to the acoustic climate.

  2. Operating experience feedback report - Air systems problems

    International Nuclear Information System (INIS)

    Ornstein, H.L.

    1987-12-01

    This report highlights significant operating events involving observed or potential failures of safety-related systems in U.S. plants that resulted from degraded or malfunctioning non-safety grade air systems. Based upon the evaluation of these events, the Office for Analysis and Evaluation of Operational Data (AEOD) concludes that the issue of air systems problems is an important one which requires additional NRC and industry attention. This report also provides AEOD's recommendations for corrective actions to deal with the issue. (author)

  3. Diaphragms in air-operated valves

    Energy Technology Data Exchange (ETDEWEB)

    Groeger, J.E.

    1996-12-01

    The author will present current issues related to diaphgrams in air-operated valves. Altran Materials Engineering, Inc., often performs root-cause analyses for nuclear power plant owners. The author will discuss various analyses that have been performed or are currently underway.

  4. The advantages and disadvantages of centralized control of air power at operational level

    Science.gov (United States)

    Arisoy, Uǧur

    2014-05-01

    People do not want to see and hear a war. In today's world, if war is inevitable, the use of air power is seen as the preferable means of conducting operations instead of financially burdensome land battles which are more likely to cause heavy loss of life. The use of Air Power has gained importance in NATO operations in the Post-Cold War era. For example, air power has undertaken a decisive role from the beginning to the end of the operation in Libya. From this point of view, the most important issue to consider is how to direct air power more effectively at operational level. NATO's Core JFAC (Joint Force Air Command) was established in 2012 to control joint air power at operational level from a single center. US had experienced JFAC aproach in the Operation Desert Storm in 1991. UK, France, Germany, Italy and Spain are also directing their air power from their JFAC structures. Joint air power can be directed from a single center at operational level by means of JFAC. JFAC aproach provides complex planning progress of Air Power to be controled faster in a single center. An Air Power with a large number of aircrafts, long range missiles of cutting-edge technology may have difficulties in achieving results unless directed effectively. In this article, directing air power more effectively at operational level has been studied in the framework of directing air power from a single center carried out by SWOT analysis technique. "Directing Air Power at operational level from a single center similar to JFAC-like structure" is compared with "Directing Air Power at operational level from two centers similar to AC (Air Command) + CAOC (Combined Air Operations Center) structure" As a result of this study, it is assessed that directing air power at operational level from a single center would bring effectiveness to the air campaign. The study examines directing air power at operational level. Developments at political, strategic and tactical levels have been ignored.

  5. Harmonic voltage excess problem test and analysis in UHV and EHV grid particular operation mode

    Science.gov (United States)

    Lv, Zhenhua; Shi, Mingming; Fei, Juntao

    2018-02-01

    The test and analysis of the power quality of some 1000kV UHV transmission lines and 500kV EHV transmission lines is carried out. It is found that there is harmonic voltage excess problems when the power supply of the UHV and EHV voltage line is single-ended or single-loop, the problem basically disappeared after the operation mode change, different operating conditions, the harmonic current has not been greatly affected, indicating that the harmonic voltage changes mainly caused by the system harmonic impedance. With the analysis of MATLAB Simulink system model, it can be seen that there are specific harmonic voltage excess in the system under the specific operating mode, which results in serious distortion of the specific harmonic voltage. Since such phenomena are found in 500kV and 1000kV systems, it is suggested that the test evaluation work should be done under the typical mode of operation in 500kV, 1000kV Planning and construction process to prevent the occurrence of serious distortion and the regional harmonic current monitoring and suppression work should be done.

  6. CUTTING THE CORD: SUSTAINING UNTETHERED AIR SUPERIORITY OPERATIONS IN THE PACIFIC

    Science.gov (United States)

    2016-06-01

    AU/ACSC/2016 AIR COMMAND AND STAFF COLLEGE AIR UNIVERSITY CUTTING THE CORD: SUSTAINING UNTETHERED AIR SUPERIORITY OPERATIONS IN THE PACIFIC...advanced their weapons systems may be. Since the end of the Cold War, the USAF has generated sorties from main operating bases ( MOB ) in support of...Operations Desert Storm, Allied Force, Enduring Freedom, and Iraqi Freedom. MOBs in rear sanctuaries allow aircraft to operate safely from enemy attack

  7. Effect of excess air on second-generation PFB combustion plant performance and economics

    International Nuclear Information System (INIS)

    Robertson, A.; Garland, R.; Newby, R.; Rehmat, A.; Rubow, L.; Bonk, D.

    1990-01-01

    This paper presents a conceptual design of a 1.4-MPa (14-atm) coal-fired second-generation pressurized fluidized bed (PFB) combustion plant and identifies the performance and economic changes that result as the excess air and thus gas turbine-to-steam turbine power ratio, is changed. The performance of these plants, another second- generation PFB combustion plant, and a conventional pulverized-coal (PC)-fired plant with wet limestone flue gas desulfurization is compared. Depending upon the conditions selected, the PFB combustion plant can achieve a 45 percent efficiency (based on the higher heating value of the coal used as fuel) and a cost of electricity at least 20 percent lower than that of the conventional PC-fired plant

  8. Investigation of Continuous Gas Engine CHP Operation on Biomass Producer Gas

    DEFF Research Database (Denmark)

    Ahrenfeldt, Jesper; Henriksen, Ulrik Birk; Jensen, Torben Kvist

    2005-01-01

    More than 2000 hours of gas engine operation with producer gas from biomass as fuel has been conducted on the gasification CHP demonstration and research plant, named “Viking” at the Technical University of Denmark. The gas engine is an integrated part of the entire gasification plant. The excess...... operates with varying excess of air due to variation in gas composition and thus stoichiometry, and a second where the excess of air in the exhaust gas is fixed and the flow rate of produced gas from the gasifier is varying. The interaction between the gas engine and the gasification system has been...... investigated. The engine and the plant are equipped with continuously data acquisition that monitors the operation including the composition of the producer gas and the flow. Producer gas properties and contaminations have been investigated. No detectable tar or particle content was observed...

  9. Traffic in the operating room: a review of factors influencing air flow and surgical wound contamination.

    Science.gov (United States)

    Pokrywka, Marian; Byers, Karin

    2013-06-01

    Surgical wound contamination leading to surgical site infection can result from disruption of the intended airflow in the operating room (OR). When personnel enter and exit the OR, or create unnecessary movement and traffic during the procedure, the intended airflow in the vicinity of the open wound becomes disrupted and does not adequately remove airborne contaminants from the sterile field. An increase in the bacterial counts of airborne microorganisms is noted during increased activity levels within the OR. Researchers have studied OR traffic and door openings as a determinant of air contamination. During a surgical procedure the door to the operating room may be open as long as 20 minutes out of each surgical hour during critical procedures involving implants. Interventions into limiting excessive movement and traffic in the OR may lead to reductions in surgical site infections in select populations.

  10. Continuous Air Monitor Operating Experience Review

    International Nuclear Information System (INIS)

    Cadwallader, L.C.; Bruyere, S.A.

    2008-01-01

    Continuous air monitors (CAMs) are used to sense radioactive particulates in room air of nuclear facilities. CAMs alert personnel of potential inhalation exposures to radionuclides and can also actuate room ventilation isolation for public and environmental protection. This paper presents the results of a CAM operating experience review of the DOE Occurrence Reporting and Processing System (ORPS) database from the past 18 years. Regulations regarding these monitors are briefly reviewed. CAM location selection and operation are briefly discussed. Operating experiences reported by the U.S. Department of Energy and in other literature sources were reviewed to determine the strengths and weaknesses of these monitors. Power losses, human errors, and mechanical issues cause the majority of failures. The average 'all modes' failure rate is 2.65E-05/hr. Repair time estimates vary from an average repair time of 9 hours (with spare parts on hand) to 252 hours (without spare parts on hand). These data should support the use of CAMs in any nuclear facility, including the National Ignition Facility and the international ITER experiment

  11. Operability test procedure for 241-U compressed air system and heat pump

    International Nuclear Information System (INIS)

    Freeman, R.D.

    1994-01-01

    The 241-U-701 compressed air system supplies instrument quality compressed air to Tank Farm 241-U. The supply piping to the 241-U Tank Farm is not included in the modification. Modifications to the 241-U-701 compressed air system include installation of a 15 HP Reciprocating Air Compressor, Ingersoll-Rand Model 10T3NLM-E15; an air dryer, Hankinson, Model DH-45; and miscellaneous system equipment and piping (valves, filters, etc.) to meet the design. A newly installed heat pump allows the compressor to operate within an enclosed relatively dust free atmosphere and keeps the compressor room within a standard acceptable temperature range, which makes possible efficient compressor operation, reduces maintenance, and maximizes compressor operating life. This document is an Operability Test Procedure (OTP) which will further verify (in addition to the Acceptance Test Procedure) that the 241-U-701 compressed air system and heat pump operate within their intended design parameters. The activities defined in this OTP will be performed to ensure the performance of the new compressed air system will be adequate, reliable and efficient. Completion of this OTP and sign off of the OTP Acceptance of Test Results is necessary for turnover of the compressed air system from Engineering to Operations

  12. Suggestions for removing operational faults in air filter plants

    Energy Technology Data Exchange (ETDEWEB)

    Ochs, H J

    1980-11-01

    Air filters are expected to achieve certain performances within their duty, viz. to precipitate air-alien matter in the air stream, the results of which will have to be checked. As a number of external influences affect the function of the air filter and, therefore, may alter the pre-defined data, checking should not only cover the air filter but also the other parts of the ventilating plant, to assure a faultless continuous operation.

  13. 30 CFR 90.205 - Approved sampling devices; operation; air flowrate.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approved sampling devices; operation; air... LABOR COAL MINE SAFETY AND HEALTH MANDATORY HEALTH STANDARDS-COAL MINERS WHO HAVE EVIDENCE OF THE DEVELOPMENT OF PNEUMOCONIOSIS Sampling Procedures § 90.205 Approved sampling devices; operation; air flowrate...

  14. 40 CFR 76.13 - Compliance and excess emissions.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Compliance and excess emissions. 76.13 Section 76.13 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) ACID RAIN NITROGEN OXIDES EMISSION REDUCTION PROGRAM § 76.13 Compliance and excess emissions...

  15. 14 CFR Special Federal Aviation... - Air Traffic Control System Emergency Operation

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Air Traffic Control System Emergency Operation Federal Special Federal Aviation Regulation No. 60 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES GENERAL OPERATING AND FLIGHT RULES Pt. 91, SFAR No. 60...

  16. Command and Control for Joint Air Operations

    Science.gov (United States)

    2010-01-12

    systems, to include collaborative air planning tools such as the theater battle management core system ( TBMCS ). Operational level air planning occurs in...sight communications and data exchange equipment in order to respond to joint force requirements. For example, the TBMCS is often used. The use of ATO...generation and dissemination software portions of TBMCS has been standardized. This ATO feature allows the JAOC to be interoperable with other

  17. Testing and operation of nuclear air-cleaning systems in Qinshan NPP

    International Nuclear Information System (INIS)

    Yang Lin

    1993-01-01

    The components of nuclear air-cleaning system, system function, operational mode and the performance of cleaning components in Qinshan Nuclear Power Plant are described. The items, purpose, methods and results of in-place testing after the installation are also described in detail. The in-place testing verifies that nuclear air-cleaning systems in Qinshan Nuclear Power Plant are reliable and high effective. It also describes the points of the operational management. It is shown that the good operational management is the key which developed prescription function of nuclear air-cleaning systems. At present, Qinshan Nuclear Power Plant will be in full power, the normal operation of the system is satisfied with the demand of safe operation in Qinshan Nuclear Power Company

  18. Operability Test Report for 241-U Compressed Air System and heat pump

    International Nuclear Information System (INIS)

    Rensink, G.E.

    1995-01-01

    The 241-U-701 compressed air system supplies instrument quality compressed air to Tank Farm 241-U. The system was upgraded. The operability test showed that the system operates within its intended design parameters. System performance was monitored, recorded, and used to identify areas of concern. Exceptions to the OTP and additional items for safe system performance were minimal and have been resolved; the air system is ready for Operation's use

  19. Commercial Air Carrier Vulnerabilities to Information Operations

    National Research Council Canada - National Science Library

    Shelburn, Bryan H

    2002-01-01

    .... Among those elements susceptible to these vulnerabilities are the operations of commercial air carriers that are essential to the military's ability to wage war and project power wherever needed in the world...

  20. Polymer electrolyte fuel cells: flow field for efficient air operation

    Energy Technology Data Exchange (ETDEWEB)

    Buechi, F N; Tsukada, A; Haas, O; Scherer, G G [Paul Scherrer Inst. (PSI), Villigen (Switzerland)

    1997-06-01

    A new flow field was designed for a polymer electrolyte fuel cell stack with an active area of 200 cm{sup 2} for operation at low air stoichiometry and low air over pressure. Optimum of gas flow and channel dimensions were calculated based on the required pressure drop in the fluid. Single cells and a bi-cell stack with the new flow field show an improved current/voltage characteristic when operated at low air stoichiometries as compared to that of the previous non optimized design. (author) 4 figs., 3 refs.

  1. Air quality compliance improvements through operational management of air resources (OMAR)

    International Nuclear Information System (INIS)

    Goddard, W.B.; Goddard, C.B.

    1990-01-01

    Geothermal well fields and power plants require operational and emergency atmospheric venting. Venting activities are monitored for compliance with regulations which limit air pollutant emissions and Ambient Air Quality Standards (AAQS). Continuous compliance monitoring data which includes hydrogen sulfide (H2S) levels and meteorological conditions is only available moths after being compiled. In this paper an automated computerized system called OMAR is described in the following which checks data and allows users access to real-time and near real-time data reports. The data can then be used for managing necessary venting or other real-time data needs. The OMAR system hardware and software is descried and is in use at The Geysers and at the Coso KGRA geothermal developments in California. The system has been designed to assist developers, engineers, scientists, and the local air districts in their goal of maintaining ambient air quality within Federal, State and Local standards

  2. New Clean Air Act complicates power plant operation, design

    International Nuclear Information System (INIS)

    Smock, R.W.

    1991-01-01

    In November the president signed into law the new Clean Air Act, ushering in a new era in the power generation industry. This paper reviews the six important sections of the Clean Air Act and their impact on power plant operation and design

  3. Lower operating cost due to compressed-air recirculation

    Energy Technology Data Exchange (ETDEWEB)

    Schauwecker, F

    1979-01-01

    Compressed air containing dirt and aggressive substances may cause damage in pipelines and pneumatic tools, equipment and systems. In consequence, operating costs can be greatly reduced by cleaning and recirculation of compressed air. Compressed-air driers are among the most common systems used for this purpose. Most of these driers are refrigeration driers; adsorption driers are less common. Refrigeration driers consist of a heat exchanger system, a separation system, and a power-controlled refrigerator. The water vapour concentration is proportional to the air temperature; for this reason, the pressure dew point should be as low as possible, i.e. about 1.5/sup 0/C.

  4. 14 CFR 203.5 - Compliance as condition on operations in air transportation.

    Science.gov (United States)

    2010-01-01

    ... air transportation. 203.5 Section 203.5 Aeronautics and Space OFFICE OF THE SECRETARY, DEPARTMENT OF... DEFENSES § 203.5 Compliance as condition on operations in air transportation. It shall be a condition on the authority of all direct U.S. and foreign carriers to operate in air transportation that they have...

  5. 30 CFR 75.323 - Actions for excessive methane.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Actions for excessive methane. 75.323 Section... excessive methane. (a) Location of tests. Tests for methane concentrations under this section shall be made.... (1) When 1.0 percent or more methane is present in a working place or an intake air course, including...

  6. 14 CFR 93.177 - Operations in the Special Air Traffic Rule Area.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Operations in the Special Air Traffic Rule Area. 93.177 Section 93.177 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES SPECIAL AIR TRAFFIC RULES Special Flight Rules in the Vicinity of Luke AFB, AZ §...

  7. Performance analysis of air conditioning system and airflow simulation in an operating theater

    Science.gov (United States)

    Alhamid, Muhammad Idrus; Budihardjo, Rahmat

    2018-02-01

    The importance of maintaining performance of a hospital operating theater is to establish an adequate circulation of clean air within the room. The parameter of air distribution in a space should be based on Air Changes per Hour (ACH) to maintain a positive room pressure. The dispersion of airborne particles in the operating theater was governed by regulating the air distribution so that the operating theater meets clean room standards ie ISO 14664 and ASHRAE 170. Here, we introduced several input parameters in a simulation environment to observe the pressure distribution in the room. Input parameters were air temperature, air velocity and volumetric flow rate entering and leaving room for existing and designed condition. In the existing operating theatre, several observations were found. It was found that the outlet air velocity at the HEPA filter above the operating table was too high thus causing a turbulent airflow pattern. Moreover, the setting temperature at 19°C was found to be too low. The supply of air into the room was observed at lower than 20 ACH which is under the standard requirement. Our simulation using FloVent 8.2™ program showed that not only airflow turbulence could be reduced but also the amount of particle contamination could also be minimized.

  8. Impact of operating wood-burning stoves on indoor air quality

    DEFF Research Database (Denmark)

    Afshari, Alireza; Jensen, Ole Michael; Bergsøe, Niels Christian

    2011-01-01

    A field study on the impact of operating and reloading wood-burning stoves on the indoor air quality was carried out during two consecutive winters. In contrast to the majority of recent studies, which focussed on the ambient air quality and the penetration of particles to the indoor air......, this study aims to understand to what extent the operation of a stove contributes to the generation of concentration of ultrafine particles in the indoor air. Therefore, different stoves were ignited in one session by the owner of the stove and in a subsequent session by an expert on wood-burning stoves....... The study was conducted in seven typical Danish detached houses without other indoor activities taking place. In each house the average air change rate during one week was measured (using passive tracer gas technique) and the indoor and outdoor temperature and relative humidity were recorded continuously...

  9. Controlled air incineration

    International Nuclear Information System (INIS)

    Seitz, K.A.

    1991-01-01

    From 1960 to 1970, incineration was recognized as an economical method of solid waste disposal with many incinerators in operation through the country. During this period a number of legislation acts began to influence the solid waste disposal industry, namely, the Solid Waste Disposal Act of 1965; Resource Conservation Recovery Act (RCRA) of 1968; Resource Recovery Act of 1970; and Clean Air Act of 1970. This period of increased environmental awareness and newly created regulations began the closure of many excess air incineration facilities and encouraged the development of new controlled air, also known as Starved-Air incinerator systems which could meet the more stringent air emission standards without additional emission control equipment. The Starved-Air technology initially received little recognition because it was considered unproven and radically different from the established and accepted I.I.A. standards. However, there have been many improvements and developments in the starved-air incineration systems since the technology was first introduced and marketed, and now these systems are considered the proven technology standard

  10. Event Sequence Analysis of the Air Intelligence Agency Information Operations Center Flight Operations

    National Research Council Canada - National Science Library

    Larsen, Glen

    1998-01-01

    This report applies Event Sequence Analysis, methodology adapted from aircraft mishap investigation, to an investigation of the performance of the Air Intelligence Agency's Information Operations Center (IOC...

  11. Air quality monitoring of the post-operative recovery room and locations surrounding operating theaters in a medical center in Taiwan.

    Directory of Open Access Journals (Sweden)

    Chin-Sheng Tang

    Full Text Available To prevent surgical site infection (SSI, the airborne microbial concentration in operating theaters must be reduced. The air quality in operating theaters and nearby areas is also important to healthcare workers. Therefore, this study assessed air quality in the post-operative recovery room, locations surrounding the operating theater area, and operating theaters in a medical center. Temperature, relative humidity (RH, and carbon dioxide (CO2, suspended particulate matter (PM, and bacterial concentrations were monitored weekly over one year. Measurement results reveal clear differences in air quality in different operating theater areas. The post-operative recovery room had significantly higher CO2 and bacterial concentrations than other locations. Bacillus spp., Micrococcus spp., and Staphylococcus spp. bacteria often existed in the operating theater area. Furthermore, Acinetobacter spp. was the main pathogen in the post-operative recovery room (18% and traumatic surgery room (8%. The mixed effect models reveal a strong correlation between number of people in a space and high CO2 concentration after adjusting for sampling locations. In conclusion, air quality in the post-operative recovery room and operating theaters warrants attention, and merits long-term surveillance to protect both surgical patients and healthcare workers.

  12. Air quality monitoring of the post-operative recovery room and locations surrounding operating theaters in a medical center in Taiwan.

    Science.gov (United States)

    Tang, Chin-Sheng; Wan, Gwo-Hwa

    2013-01-01

    To prevent surgical site infection (SSI), the airborne microbial concentration in operating theaters must be reduced. The air quality in operating theaters and nearby areas is also important to healthcare workers. Therefore, this study assessed air quality in the post-operative recovery room, locations surrounding the operating theater area, and operating theaters in a medical center. Temperature, relative humidity (RH), and carbon dioxide (CO2), suspended particulate matter (PM), and bacterial concentrations were monitored weekly over one year. Measurement results reveal clear differences in air quality in different operating theater areas. The post-operative recovery room had significantly higher CO2 and bacterial concentrations than other locations. Bacillus spp., Micrococcus spp., and Staphylococcus spp. bacteria often existed in the operating theater area. Furthermore, Acinetobacter spp. was the main pathogen in the post-operative recovery room (18%) and traumatic surgery room (8%). The mixed effect models reveal a strong correlation between number of people in a space and high CO2 concentration after adjusting for sampling locations. In conclusion, air quality in the post-operative recovery room and operating theaters warrants attention, and merits long-term surveillance to protect both surgical patients and healthcare workers.

  13. Numerical study of aerodynamics and brown coal combustion in the vortex furnace with air excess variation

    Directory of Open Access Journals (Sweden)

    Krasinsky Denis

    2017-01-01

    Full Text Available The results of numerical modelling of 3D turbulent two-phase reacting flow with account for all the principal heat and mass transfer processes during the pulverized brown coal combustion in the vortex furnace of a power plant boiler unit have been presented. For two computational cases where air excess coefficient α was varied (set to 1.15 and 1.25, the detailed aerothermochemical 3D structure of reacting flow in the furnace volume has been revealed. The comparison of integral heat engineering parameters and NOx emissions obtained in the two cases has shown a slightly improved vortex furnace performance in the case α=1.25.

  14. Effect of ventilation rate on air cleanliness and energy consumption in operation rooms at rest.

    Science.gov (United States)

    Lee, Shih-Tseng; Liang, Ching-Chieh; Chien, Tsung-Yi; Wu, Feng-Jen; Fan, Kuang-Chung; Wan, Gwo-Hwa

    2018-02-27

    The interrelationships between ventilation rate, indoor air quality, and energy consumption in operation rooms at rest are yet to be understood. We investigate the effect of ventilation rate on indoor air quality indices and energy consumption in ORs at rest. The study investigates the air temperature, relative humidity, concentrations of carbon dioxide, particulate matter (PM), and airborne bacteria at different ventilation rates in operation rooms at rest of a medical center. The energy consumption and cost analysis of the heating, ventilating, and air conditioning (HVAC) system in the operation rooms at rest were also evaluated for all ventilation rates. No air-conditioned operation rooms had very highest PM and airborne bacterial concentrations in the operation areas. The bacterial concentration in the operation areas with 6-30 air changes per hour (ACH) was below the suggested level set by the United Kingdom (UK) for an empty operation room. A 70% of reduction in annual energy cost by reducing the ventilation rate from 30 to 6 ACH was found in the operation rooms at rest. Maintenance of operation rooms at ventilation rate of 6 ACH could save considerable amounts of energy and achieve the goal of air cleanliness.

  15. Excess 129Xe in terrestrial samples: A non-primordial hypothesis

    International Nuclear Information System (INIS)

    Caffee, M.W.; Hudson, G.B.

    1987-03-01

    Excesses of 129 Xe relative to the isotopic composition in air are observed in some terrestrial samples. Traditionally these 129 Xe excesses have been thought to be related to 129 I that was present in abundance in the early solar system. We propose an alternative hypothesis to explain terrestrial 129 Xe excesses based on the production of 129 I from the spontaneous fission of 238 U

  16. Study of high load operation limit for premixed compression ignition engine; Yokongo asshuku chakka kikan no kofuka unten genkai ni kansuru kosatsu

    Energy Technology Data Exchange (ETDEWEB)

    Shimazaki, N. [Isuzu Advanced Engineering Center Ltd., Kanagawa (Japan); Akagawa, H. [Nissan Diesel Motor Co. Ltd., Saitama (Japan); Tsujimura, K. [Chiba Institute of Technology, Chiba (Japan); Miyamoto, T.

    2000-11-25

    NO{sub x} emission was remarkably reduced by PREDIC (PREmixed lean DIesel Combustion) system in which fuel was injected at very early stage of compression stroke and the major part of the fuel is considered to be burned with self-ignition of premixed charge around TDC. However PREDIC system had some problems, a restriction of a high load operation was one of these problems. In order to investigate the combustion characteristics of PREDIC at the richer operation limit, a test engine was operated with gaseous fuel-air mixture where less heterogeneous mixture can be formed than that of conventional diesel engines. A steep pressure rise or the abrupt increase in NO{sub x} emission determined the richer operation limit. This was at 2 to 2.4 of excess air ratio. Supercharging operation enabled the high load operation more than 2.4 of excess air ratio. (author)

  17. Future's operation areas: new-generation suppression enemy air defence (SEAD) elements

    Science.gov (United States)

    Hazinedar, Ä.°lker

    2015-05-01

    Since air vehicles took place in the theater of operations, they have become the indispensable elements and the strongest attack power of armed forces. In the following period, with technological development, supersonic aircrafts took place in the operation area and this increased effectiveness of air vehicles much more. Air forces have used these aircrafts during important missions like strategic attack and air defense operations. On the other hand, decision makers understood that it was not feasible to intercept fighter aircrafts by executing combat air patrol flight missions. Since there is not enough reaction time to intercept the high speed aircrafts, ground stationed Surface to Air Missiles (SAM) system requirement has emerged. Therefore, SAM systems took place in the operation scene as well. Due to the fact that SAM systems emerged against the attack power, the attack aircrafts are to keep away from the fire of the ground stationed SAM systems. Hence, the requirement of Suppression Enemy Air Defense (SEAD) arose. SEAD elements take under suppression the radar of the SAM systems. In this way, attack aircrafts are able to attack without the risk of SAM systems. The purpose of this study is to find new methods or concepts in order to protect friendly attack aircrafts against ground based surface to air missiles' fires. Modernization of SAM systems and new generation SAM system producing activities have proceeded with positive acceleration. So, current SEAD elements and concepts are not able to cover the requirements due to the increased SAM system ranges. According to the concepts, SEAD weapons` ranges must be longer than the SAM weapons' ranges to protect friendly aircrafts. In this study, new concept was offered to overcome the deficiencies of current SEAD concept. The elements of new concepts were put forward. Classic SEAD concept and new generation concepts were assessed by using SWOT analysis technique. As a result, this study has revealed that, air forces

  18. Effects of cathode channel size and operating conditions on the performance of air-blowing PEMFCs

    International Nuclear Information System (INIS)

    Kim, Bosung; Lee, Yongtaek; Woo, Ahyoung; Kim, Yongchan

    2013-01-01

    Highlights: • Effect of cathode channel size on the air-blowing PEMFC is analyzed. • Performance and EIS tests of air-blowing PEMFCs are conducted. • Test conditions include the operating temperature, fan voltage, and anode humidity. • Flooding is a limiting factor for decreasing channel size at low temperature. • Water management is investigated by analyzing ohmic resistance. - Abstract: Air-blowing proton exchange membrane fuel cells (PEMFCs) have been developed as a potential new power source for portable electronic devices. However, air-blowing PEMFCs show lower performance than compressed-air PEMFCs because of their adverse operating conditions. In this study, the effects of the cathode channel size and operating conditions on the performance of the air-blowing PEMFC were analyzed. At the normal operating temperature, the performance of the air-blowing PEMFC improved with the decrease in the cathode channel size. However, at a low operating temperature and low fan voltage, massive flooding limits the decrease in the cathode channel size. In addition, water management in the air-blowing PEMFC was investigated by analyzing ohmic resistance. The transition current density between the humidification and the flooding region decreased with decreasing cathode channel size and operating temperature

  19. Design for air-to-air refuelling operations; new passenger and tanker aircraft design for AAR scenarios

    NARCIS (Netherlands)

    Li, M.O.

    2014-01-01

    Air-to-air refuelling is a way to improve fuel efficiency of the overall transport system without waiting for the improvement of basic aviation technology. To take full advantage of such an operation, both passenger aircraft and tanker aircraft (which deliver required fuel to the passenger aircraft

  20. Optimal distribution of reactivity excess in a system of reactors operating at a variable loading schedule

    International Nuclear Information System (INIS)

    Bolsunov, A.A.; Zagrebaev, A.M.; Naumov, V.I.

    1979-01-01

    Considered is the task of reactivity excess distribution optimization in the system of reactors for the purpose of minimazing the summary power production losses at the fixed loading schedule. Mathematical formulation of the task is presented. Given are the curves, characterizing the dependence of possible degree of the reactor power drop on reactivity excees for non-stationary Xe poisoning at different nominal density of neutron flux. Analyzing the results, it is concluded that in case, when the reactors differ only in neutron flux density the reactor with lower neutron flux density should be involved in the variable operation schedule first as the poisoning of this reactor will be less, and therefore, the losses of the system power production will be less. It is advisable to reserve the reactivity excess in the reactor with greater power or in the reactor with higher burnup rate. It is stressed that the obtained results of the optimization task solution point out the possibility of obtaining the certain ecomonic effect and permit to correct the requirements on mobility of separate power units at system approach to NPP operation in a variable loading schedule

  1. Final Environmental Assessment for the First Air Force Air Operations Center, First Air Force Headquarters/Air Force Forces Center, and Highway 98 Overpass at Tyndall Air Force Base, Florida

    Science.gov (United States)

    2004-01-01

    no comments regarding the Draft Environmental Assessment for the First Air Force Operations Center, First Air Force Headquarters/Air Force Forces...COUNCIL ] No Comment BAY - BAY COUNTY No Final Comments Received ENVIRONMENTAL POLICY UNIT - OFFICE OF POLICY AND BUDGET, ENVIRONMENTAL POLICY UNIT NO ...CONSERVATION COMMISSION [ NO COMMENT BY BRIAN BARNETT ON 4/12/04. [STATE - FLORIDA DEPARTMENT OF STATE [ No Comment [TRANSPORTATION - FLORIDA DEPARTMENT

  2. The Future of the Brigade Combat Team: Air-Ground Integration and the Operating Environment

    Science.gov (United States)

    2017-06-09

    coordinate, and control joint and multinational aircraft during CAS situations in combat and training. The current system which the CAS mission falls...current system , experiences from Vietnam, Operation Desert Storm, Afghanistan and Iraq help to identify future challenges to the operating environment ...multinational partners. 15. SUBJECT TERMS Air Ground Integration, Theater Air Ground System , Theater Air Control System , Army Air Ground System , Joint

  3. Operational air quality forecasting system for Spain: CALIOPE

    Science.gov (United States)

    Baldasano, J. M.; Piot, M.; Jorba, O.; Goncalves, M.; Pay, M.; Pirez, C.; Lopez, E.; Gasso, S.; Martin, F.; García-Vivanco, M.; Palomino, I.; Querol, X.; Pandolfi, M.; Dieguez, J. J.; Padilla, L.

    2009-12-01

    The European Commission (EC) and the United States Environmental Protection Agency (US-EPA) have shown great concerns to understand the transport and dynamics of pollutants in the atmosphere. According to the European directives (1996/62/EC, 2002/3/EC, 2008/50/EC), air quality modeling, if accurately applied, is a useful tool to understand the dynamics of air pollutants, to analyze and forecast the air quality, and to develop programs reducing emissions and alert the population when health-related issues occur. The CALIOPE project, funded by the Spanish Ministry of the Environment, has the main objective to establish an air quality forecasting system for Spain. A partnership of four research institutions composes the CALIOPE project: the Barcelona Supercomputing Center (BSC), the center of investigation CIEMAT, the Earth Sciences Institute ‘Jaume Almera’ (IJA-CSIC) and the CEAM Foundation. CALIOPE will become the official Spanish air quality operational system. This contribution focuses on the recent developments and implementation of the integrated modelling system for the Iberian Peninsula (IP) and Canary Islands (CI) with a high spatial and temporal resolution (4x4 sq. km for IP and 2x2 sq. km for CI, 1 hour), namely WRF-ARW/HERMES04/CMAQ/BSC-DREAM. The HERMES04 emission model has been specifically developed as a high-resolution (1x1 sq. km, 1 hour) emission model for Spain. It includes biogenic and anthropogenic emissions such as on-road and paved-road resuspension production, power plant generation, ship and plane traffic, airports and ports activities, industrial and agricultural sectors as well as domestic and commercial emissions. The qualitative and quantitative evaluation of the model was performed for a reference year (2004) using data from ground-based measurement networks. The products of the CALIOPE system will provide 24h and 48h forecasts for O3, NO2, SO2, CO, PM10 and PM2.5 at surface level. An operational evaluation system has been developed

  4. Theoretical and Experimental Investigations of Highly Uprated Diesel Engine with Temperature Regulator of Supercharging Air

    Directory of Open Access Journals (Sweden)

    G. A. Vershina

    2005-01-01

    Full Text Available Mathematical model of a highly uprated diesel engine with turbo-supercharging and intercooler of supercharging air is given in die paper. Theoretical study based on the model has made it possible to design and test an intercooler with a temperature regulator of supercharging air. Test results prove efficiency of temperature regulation of supercharging air in operation of an engine at low loads with excess air factor more than 3.2.

  5. Deterrence of ballistic missile systems and their effects on today's air operations

    Science.gov (United States)

    Durak, Hasan

    2015-05-01

    Lately, the effect-based approach has gained importance in executing air operations. Thus, it makes more successful in obtaining the desired results by breaking the enemy's determination in a short time. Air force is the first option to be chosen in order to defuse the strategic targets. However, the problems such as the defense of targets and country, radars, range…etc. becoming serious problems. At this level ballistic missiles emerge as a strategic weapon. Ultimate emerging technologies guided by the INS and GPS can also be embedded with multiple warheads and reinforced with conventional explosive, ballistic missiles are weapons that can destroy targets with precision. They have the advantage of high speed, being easily launched from every platform and not being easily detected by air defense systems contrary to other air platforms. While these are the advantages, there are also disadvantages of the ballistic missiles. The high cost, unavailability of nuclear, biological and chemical weapons, and its limited effect while using conventional explosives against destroying the fortified targets are the disadvantages. The features mentioned above should be considered as limitation to the impact of the ballistic missiles. The aim is to impose the requests on enemies without starting a war with all components and to ensure better implementation of the operation functions during the air operations. In this study, effects of ballistic missiles in the future on air battle theatre will be discussed in the beginning, during the process and at the end phase of air operations within the scope of an effect-based approach.

  6. Consideration of Fugitives in Open-Air Cattle Operations

    Science.gov (United States)

    This document may be of assistance in applying the Title V air operating permit regulations. This document is part of the Title V Policy and Guidance Database available at www2.epa.gov/title-v-operating-permits/title-v-operating-permit-policy-and-guidance-document-index. Some documents in the database are a scanned or retyped version of a paper photocopy of the original. Although we have taken considerable effort to quality assure the documents, some may contain typographical errors. Contact the office that issued the document if you need a copy of the original.

  7. Eielson Air Force Base Operable Unit 2 baseline risk assessment

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, R.E.; Jarvis, T.T.; Jarvis, M.R.; Whelan, G.

    1994-10-01

    Operable Unit 2 at Eielson Air Force Base (AFB) near Fairbanks, is one of several operable units characterized by petroleum, oil, and lubricant contamination, and by the presence of organic products floating at the water table, as a result of Air Force operations since the 1940s. The base is approximately 19,270 acres in size, and comprises the areas for military operations and a residential neighborhood for military dependents. Within Operable Unit 2, there are seven source areas. These source areas were grouped together primarily because of the contaminants released and hence are not necessarily in geographical proximity. Source area ST10 includes a surface water body (Hardfill Lake) next to a fuel spill area. The primary constituents of concern for human health include benzene, toluene, ethylbenzene, and xylenes (BTEX). Monitored data showed these volatile constituents to be present in groundwater wells. The data also showed an elevated level of trace metals in groundwater.

  8. Operational air sampling report, January--June 30, 1992

    International Nuclear Information System (INIS)

    Lyons, C.L.

    1992-09-01

    Nevada Test Site postshot and tunnel events generate beta/gamma fission products. The Reynolds Electrical ampersand Engineering Co., Inc. air sampling program is designed for measurement of these radionuclides at various facilities supporting these events. Monthly radon sampling is done for documentation of working levels in the tunnel complexes, which would be expected to hove the highest radon levels for on-site facilities. Out of a total of 281 air samples taken in the tunnel complexes, 25 showed airborne fission products with concentrations well below their respective Derived Air Concentrations (DAC). All of these were related to event reentry or mineback operations. Tritiated water vapor and radon levels were very similar to previously reported levels. The 975 air samples taken at the Area-6 decontamination bays and laundry were again well below any DAC calculation standard and negative for any airborne fission products from laboratory analyses

  9. Data mining of air traffic control operational errors

    Science.gov (United States)

    2006-01-01

    In this paper we present the results of : applying data mining techniques to identify patterns and : anomalies in air traffic control operational errors (OEs). : Reducing the OE rate is of high importance and remains a : challenge in the aviation saf...

  10. Hyper-Spectral Networking Concept of Operations and Future Air Traffic Management Simulations

    Science.gov (United States)

    Davis, Paul; Boisvert, Benjamin

    2017-01-01

    The NASA sponsored Hyper-Spectral Communications and Networking for Air Traffic Management (ATM) (HSCNA) project is conducting research to improve the operational efficiency of the future National Airspace System (NAS) through diverse and secure multi-band, multi-mode, and millimeter-wave (mmWave) wireless links. Worldwide growth of air transportation and the coming of unmanned aircraft systems (UAS) will increase air traffic density and complexity. Safe coordination of aircraft will require more capable technologies for communications, navigation, and surveillance (CNS). The HSCNA project will provide a foundation for technology and operational concepts to accommodate a significantly greater number of networked aircraft. This paper describes two of the HSCNA projects technical challenges. The first technical challenge is to develop a multi-band networking concept of operations (ConOps) for use in multiple phases of flight and all communication link types. This ConOps will integrate the advanced technologies explored by the HSCNA project and future operational concepts into a harmonized vision of future NAS communications and networking. The second technical challenge discussed is to conduct simulations of future ATM operations using multi-bandmulti-mode networking and technologies. Large-scale simulations will assess the impact, compared to todays system, of the new and integrated networks and technologies under future air traffic demand.

  11. Network-Centric Operations Case Study: Air-to-Air Combat With and Without Link 16

    National Research Council Canada - National Science Library

    Gonzales, Daniel; Hollywood, John; Kingston, Gina; Signori, David

    2005-01-01

    ...) Operational Special Project. In this exercise, the capabilities of F-15 air superiority aircraft equipped with voice-only communications were compared with F-15s equipped with voice and JTIDS Link 16 data link communications...

  12. Operating manual for Ford's Farm Range air samplers

    International Nuclear Information System (INIS)

    Glissmeyer, J.A.; Halverson, M.A.

    1980-10-01

    An air-sampling program was designed for a target enclosure at the Ford's Farm Range, Aberdeen Proving Ground, Maryland, where the Army test-fires tungsten and depleted-uranium armor penetrators. The primary potential particle inhalation hazard is depleted uranium. The sampling program includes workplace and filtered exhaust air sampling. Conventional isokinetic stack sampling was employed for the filtered exhaust air. Because of the need for rapid monitor response to concentration increases and decreases, conventional radioactive particle monitors were not used. Instead, real-time aerosol monitors employing a light-scattering technique were used for monitors requiring a fast response. For other monitoring functions, piezoelectric and beta-attenuation respirable-particle sampling techniques were used. The application of these technologies to the monitoring of airborne radioactive contaminants is addressed. Sampler installation and operation are detailed

  13. Dynamic performance of self-operated three-way valve used in a hybrid air conditioner

    International Nuclear Information System (INIS)

    Zhang, Penglei; Zhou, Dehai; Shi, Wenxing; Li, Xianting; Wang, Baolong

    2014-01-01

    A hybrid air conditioner combining a thermosyphon cycle with a vapor compression refrigeration cycle has a large energy saving potential compared with a common air conditioner for spaces requiring year-round cooling. The performance of the switch between the vapor compression mode and the thermosyphon mode largely impacts the safety and reliability of hybrid air conditioners. Therefore, a self-operated three-way valve is proposed. A thermodynamic model and a kinetic model are developed in this paper to evaluate the dynamic performance of the switch valve. The effects of the spring force constant, compressor discharging volume, fit clearance and piston length on the dynamic performance of the switch valve are analyzed. In conclusion, the proposed self-operated three-way valve can realize the switch operation accurately. - Highlights: •A self-operated three-way valve is proposed for hybrid air conditioners. •The thermodynamic model and kinetic model of the self-operated three-way valve are developed. •The validity of models is verified by experiments. •Effects of four main design parameters on the operating performance of the valve are researched

  14. SIMULATION OF AIR-CONDITIONNED OPERATING THEATRES

    OpenAIRE

    El Gharbi , N.; Benzaoui , A ,

    2006-01-01

    International audience; A hospital is a place where we find simultaneously people whose health state is weakened, or vulnerable, and pathogenic microorganisms able to worsen their health. The quality of the air in a hospital must be in conformity with precise criteria in such buildings in everyday usage, and in particular in the areas of the buildings where some risks of specific pollution exist such as in operating rooms. In this paper, we present a modelisation and three dimensional numeric...

  15. Office of Inspector General audit report on aircraft and air service management programs

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-01-01

    The Department of Energy`s (DOE) Albuquerque Operations Office (Albuquerque) owns seven aircraft that support defense programs, research and development efforts, emergency response programs, and official travel of Government and contractor employees. An Office of Inspector General (OIG) report, issued in 1994, identified concerns with Albuquerque`s cost for air service. Since that report, there have been reductions in cost and personnel indicating changes in air service requirements. This audit was conducted to determine (1) whether costs to operate Albuquerque`s aircraft were excessive and (2) if individual aircraft in the fleet were justified.

  16. Automated Air Traffic Control Operations with Weather and Time-Constraints: A First Look at (Simulated) Far-Term Control Room Operations

    Science.gov (United States)

    Prevot, Thomas; Homola, Jeffrey R.; Martin, Lynne H.; Mercer, Joey S.; Cabrall, Christopher C.

    2011-01-01

    In this paper we discuss results from a recent high fidelity simulation of air traffic control operations with automated separation assurance in the presence of weather and time-constraints. We report findings from a human-in-the-loop study conducted in the Airspace Operations Laboratory (AOL) at the NASA Ames Research Center. During four afternoons in early 2010, fifteen active and recently retired air traffic controllers and supervisors controlled high levels of traffic in a highly automated environment during three-hour long scenarios, For each scenario, twelve air traffic controllers operated eight sector positions in two air traffic control areas and were supervised by three front line managers, Controllers worked one-hour shifts, were relieved by other controllers, took a 3D-minute break, and worked another one-hour shift. On average, twice today's traffic density was simulated with more than 2200 aircraft per traffic scenario. The scenarios were designed to create peaks and valleys in traffic density, growing and decaying convective weather areas, and expose controllers to heavy and light metering conditions. This design enabled an initial look at a broad spectrum of workload, challenge, boredom, and fatigue in an otherwise uncharted territory of future operations. In this paper we report human/system integration aspects, safety and efficiency results as well as airspace throughput, workload, and operational acceptability. We conclude that, with further refinements. air traffic control operations with ground-based automated separation assurance can be an effective and acceptable means to routinely provide very high traffic throughput in the en route airspace.

  17. Tracking atmospheric boundary layer dynamics with water vapor D-excess observations

    KAUST Repository

    Parkes, Stephen

    2015-04-01

    Stable isotope water vapor observations present a history of hydrological processes that have impacted on an air mass. Consequently, there is scope to improve our knowledge of how different processes impact on humidity budgets by determining the isotopic end members of these processes and combining them with in-situ water vapor measurements. These in-situ datasets are still rare and cover a limited geographical expanse, so expanding the available data can improve our ability to define isotopic end members and knowledge about atmospheric humidity dynamics. Using data collected from an intensive field campaign across a semi-arid grassland site in eastern Australia, we combine multiple methods including in-situ stable isotope observations to study humidity dynamics associated with the growth and decay of the atmospheric boundary layer and the stable nocturnal boundary layer. The deuterium-excess (D-excess) in water vapor is traditionally thought to reflect the sea surface temperature and relative humidity at the point of evaporation over the oceans. However, a number of recent studies suggest that land-atmosphere interactions are also important in setting the D-excess of water vapor. These studies have shown a highly robust diurnal cycle for the D-excess over a range of sites that could be exploited to better understand variations in atmospheric humidity associated with boundary layer dynamics. In this study we use surface radon concentrations as a tracer of surface layer dynamics and combine these with the D-excess observations. The radon concentrations showed an overall trend that was inversely proportional to the D-excess, with early morning entrainment of air from the residual layer of the previous day both diluting the radon concentration and increasing the D-excess, followed by accumulation of radon at the surface and a decrease in the D-excess as the stable nocturnal layer developed in the late afternoon and early evening. The stable nocturnal boundary layer

  18. Design of air distribution system in operating rooms -theory versus practice

    NARCIS (Netherlands)

    Melhado, M.A.; Loomans, M.G.L.C.; Hensen, J.L.M.; Lamberts, R.

    2016-01-01

    Air distribution systems need to secure a good indoor air quality in operating rooms (ORs), minimize the risk of surgical site infections, and establish suitable working conditions for the surgical team through the thermal comfort. The paper presents an overview of the design and decision process of

  19. Techniques for controlling air pollution from the operation of nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    1966-03-01

    This manual is provided for the guidance of those persons or authorities who are responsible for the organization, control and operation of ventilation systems and air-cleaning installations in nuclear establishments. It is intended to generalize about existing experience in the operation of such systems at nuclear facilities including reactors and laboratories for production, use and handling of radionuclides and other toxic materials. This manual will provide designers and operators of nuclear facilities in which ventilation and air-cleaning systems are used with the factors which have to be considered to create safe working conditions inside facilities and without polluting the atmosphere or the environment to a hazardous level. Refs, 24 figs, 5 tabs.

  20. Operational air sampling report, July 1--December 31, 1992

    International Nuclear Information System (INIS)

    Lyons, C.L.

    1993-04-01

    Nevada Test Site postshot and tunnel events generate beta/gamma fission products. The REECo air sampling program is designed for measurement of these radionuclides at various facilities supporting these events. Monthly radon sampling is done for documentation of working levels in the tunnel complexes, which would be expected to have the highest radon levels for on-site facilities. Out of a total of 628 air samples taken in the tunnel complexes, 24 showed airborne fission products with concentrations well below their respective Derived Air Concentrations (DAC). All of these were related to event reentry or mineback operations. Tritiated water vapor concentrations were very similar to previously reported levels. The 838 air samples taken at the Area-6 decontamination bays and laundry were again well below any DAC calculation standard and negative for any airborne fission products from laboratory analyses

  1. Information Operations as a Counter to US Air Dominance: A Rival's Perspective

    National Research Council Canada - National Science Library

    Harris, Jr, David A

    2007-01-01

    The purpose of this monograph is to answer the question of what lessons over the past ten years of US air operations have foreign militaries integrated into their doctrine and organizations to counter US air dominance...

  2. 76 FR 54528 - Standard Operating Procedures (SOP) of the Aircraft Certification Service (AIR) Process for the...

    Science.gov (United States)

    2011-09-01

    ...) of the Aircraft Certification Service (AIR) Process for the Sequencing of Certification and... on the Aircraft Certification Service (AIR) standard operating procedure (SOP) describing the process... comments on the SOP : AIR-100-001; Standard Operating Procedure--Aircraft Certification Service Project...

  3. Controlled air pyrolysis incinerator

    International Nuclear Information System (INIS)

    Dufrane, K.H.; Wilke, M.

    1982-01-01

    An advanced controlled air pyrolysis incinerator has been researched, developed and placed into commercial operation for both radioactive and other combustible wastes. Engineering efforts cocentrated on providing an incinerator which emitted a clean, easily treatable off-gas and which produced a minimum amount of secondary waste. Feed material is continuously fed by gravity into the system's pyrolysis chamber without sorting, shredding, or other such pretreatment. Metal objects, liquids such as oil and gasoline, or solid products such as resins, blocks of plastic, tire, animal carcasses, or compacted trash may be included along with normal processed waste. The temperature of the waste is very gradually increased in a reduced oxygen atmosphere. Volatile pyrolysis gases are produced, tar-like substances are cracked and the resulting product, a relatively uniform, easily burnable material, is introduced into the combustion chamber. Steady burning is thus accomplished under easily controlled excess air conditions with the off-gasthen passing through a simple dry clean-up system. Gas temperatures are then reduced by air dilution before passing through final HEPA filters. Both commercial and nuclear installations have been operated with the most recent application being the central incinerator to service West Germany's nuclear reactors

  4. 78 FR 53025 - Pilot Certification and Qualification Requirements for Air Carrier Operations; Correction

    Science.gov (United States)

    2013-08-28

    ...-0100; Amdt. No. 141-17A] RIN 2120-AJ67 Pilot Certification and Qualification Requirements for Air... regulations to create new certification and qualification requirements for pilots in air carrier operations..., the FAA published a final rule entitled, ``Pilot Certification and Qualification Requirements for Air...

  5. MODELING OF BEHAVIORAL ACTIVITY OF AIR NAVIGATION SYSTEM'S HUMAN-OPERATOR IN FLIGHT EMERGENCIES

    Directory of Open Access Journals (Sweden)

    Volodymyr Kharchenko

    2012-09-01

    Full Text Available  The Air Navigation System is presented as a complex socio-technical system. The influence on decision-making by Air Navigation System's human-operator of the professional factors as well as the factors of non-professional nature has been defined. Logic determined and stochastic models of decision-making by the Air Navigation System's human-operator in flight emergencies have been developed. The scenarios of developing a flight situation in case of selecting either the positive or negative pole in accordance with the reflexive theory have been obtained. The informational support system of the operator in the unusual situations on the basis of Neural Network model of evaluating the efficiency of the potential alternative of flight completion has been built.

  6. 78 FR 6817 - Clean Air Act Operating Permit Program; Petition for Objection to State Operating Permit for...

    Science.gov (United States)

    2013-01-31

    ... Wisconsin Public Service Corporation--JP Pulliam Plant. Pursuant to section 505(b)(2) of the Act, a... ENVIRONMENTAL PROTECTION AGENCY [FRL 9774-6] Clean Air Act Operating Permit Program; Petition for Objection to State Operating Permit for Wisconsin Public Service Corporation--JP Pulliam Plant AGENCY...

  7. Combined compressed air storage-low BTU coal gasification power plant

    Science.gov (United States)

    Kartsounes, George T.; Sather, Norman F.

    1979-01-01

    An electrical generating power plant includes a Compressed Air Energy Storage System (CAES) fueled with low BTU coal gas generated in a continuously operating high pressure coal gasifier system. This system is used in coordination with a continuously operating main power generating plant to store excess power generated during off-peak hours from the power generating plant, and to return the stored energy as peak power to the power generating plant when needed. The excess coal gas which is produced by the coal gasifier during off-peak hours is stored in a coal gas reservoir. During peak hours the stored coal gas is combined with the output of the coal gasifier to fuel the gas turbines and ultimately supply electrical power to the base power plant.

  8. A study of air-operated valves in U.S. nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Rothberg, O. [Idaho National Engineering and Environmental Laboratory, Idaho Falls, ID (United States); Khericha, S. [Idaho National Engineering and Environmental Laboratory, Idaho Falls, ID (United States); Watkins, J. [Idaho National Engineering and Environmental Laboratory, Idaho Falls, ID (United States); Holbrook, M. [Idaho National Engineering and Environmental Laboratory, Idaho Falls, ID (United States)

    2000-02-01

    A study of air-operated valves in nuclear power plant applications was conducted for the NRC Office of Research (the project was initiated by NRC/AEOD). The results of the study were based on visits to seven nuclear power plant sites, literature studies, and examinations of event records in databases available to the NRC. The purpose is to provide information to the NRC staff concerning capabilities and performance of air-operated valves (AOVs). Descriptions of air systems and AOVs were studied along with the support systems and equipment. Systems and equipment that contain AOVs and SOVs were studied to determine their dependencies. Applications of AOVs and SOVs were listed along with current NRC requirements.

  9. A study of air-operated valves in U.S. nuclear power plants

    International Nuclear Information System (INIS)

    Rothberg, O.; Khericha, S.; Watkins, J.; Holbrook, M.

    2000-01-01

    A study of air-operated valves in nuclear power plant applications was conducted for the NRC Office of Research (the project was initiated by NRC/AEOD). The results of the study were based on visits to seven nuclear power plant sites, literature studies, and examinations of event records in databases available to the NRC. The purpose is to provide information to the NRC staff concerning capabilities and performance of air-operated valves (AOVs). Descriptions of air systems and AOVs were studied along with the support systems and equipment. Systems and equipment that contain AOVs and SOVs were studied to determine their dependencies. Applications of AOVs and SOVs were listed along with current NRC requirements.

  10. Development of an air-operated actuator performance monitoring system for regulatory usage

    International Nuclear Information System (INIS)

    Sung, K. Y.; Kwon, S. J.

    2004-01-01

    The performance monitoring system of air-operated actuators for regulatory usage has been being developed. Essential elements and operating parameters affecting the actuator performance have been investigated to provide basic information for system development. The monitoring system including an air-operated actuator testing facility and analysis softwares for monitoring and evaluation are also introduced in this paper. As a result of simulated tests, it was known that the system could be a useful tool for the effective monitoring of actuator performance change and fault conditions. This system would be applied to regulatory inspection for utility's data validation and to the training of regulatory staff in future after some modification and expansion

  11. Combustion of palm kernel shell in a fluidized bed: Optimization of biomass particle size and operating conditions

    International Nuclear Information System (INIS)

    Ninduangdee, Pichet; Kuprianov, Vladimir I.

    2014-01-01

    Highlights: • Safe burning of palm kernel shell is achievable in a FBC using alumina as the bed material. • Thermogravimetric analysis of the shell with different particle sizes is performed. • Optimal values of the shell particle size and excess air lead to the minimum emission costs. • Combustion efficiency of 99.4–99.7% is achievable when operated under optimal conditions. • CO and NO emissions of the FBC are at levels substantially below national emission limits. - Abstract: This work presents a study on the combustion of palm kernel shell (PKS) in a conical fluidized-bed combustor (FBC) using alumina sand as the bed material to prevent bed agglomeration. Prior to combustion experiments, a thermogravimetric analysis was performed in nitrogen and dry air to investigate the effects of biomass particle size on thermal and combustion reactivity of PKS. During the combustion tests, the biomass with different mean particle sizes (1.5 mm, 4.5 mm, 7.5 mm, and 10.5 mm) was burned at a 45 kg/h feed rate, while excess air was varied from 20% to 80%. Temperature and gas concentrations (O 2 , CO, C x H y as CH 4 , and NO) were recorded along the axial direction in the reactor as well as at stack. The experimental results indicated that the biomass particle size and excess air had substantial effects on the behavior of gaseous pollutants (CO, C x H y , and NO) in different regions inside the reactor, as well as on combustion efficiency and emissions of the conical FBC. The CO and C x H y emissions can be effectively controlled by decreasing the feedstock particle size and/or increasing excess air, whereas the NO emission can be mitigated using coarser biomass particles and/or lower excess air. A cost-based approach was applied to determine the optimal values of biomass particle size and excess air, ensuring minimum emission costs of burning the biomass in the proposed combustor. From the optimization analysis, the best combustion and emission performance of the

  12. Exploring Concepts of Operations for On-Demand Passenger Air Transportation

    Science.gov (United States)

    Nneji, Victoria Chibuogu; Stimpson, Alexander; Cummings, Mary; Goodrich, Kenneth H.

    2017-01-01

    In recent years, a surge of interest in "flying cars" for city commutes has led to rapid development of new technologies to help make them and similar on-demand mobility platforms a reality. To this end, this paper provides analyses of the stakeholders involved, their proposed operational concepts, and the hazards and regulations that must be addressed. Three system architectures emerged from the analyses, ranging from conventional air taxi to revolutionary fully autonomous aircraft operations, each with vehicle safety functions allocated differently between humans and machines. Advancements for enabling technologies such as distributed electric propulsion and artificial intelligence have had major investments and initial experimental success, but may be some years away from being deployed for on-demand passenger air transportation at scale.

  13. An Examination of the United States Air Service's Logistics Operations

    National Research Council Canada - National Science Library

    Hunt, Andrew

    1998-01-01

    This historical study details the U.S. Air Service's logistics operations at home and abroad in an attempt to determine the relationship between the process and more recently established logistic principles...

  14. LITERATURE SEARCH FOR METHODS FOR HAZARD ANALYSES OF AIR CARRIER OPERATIONS.

    Energy Technology Data Exchange (ETDEWEB)

    MARTINEZ - GURIDI,G.; SAMANTA,P.

    2002-07-01

    Representatives of the Federal Aviation Administration (FAA) and several air carriers under Title 14 of the Code of Federal Regulations (CFR) Part 121 developed a system-engineering model of the functions of air-carrier operations. Their analyses form the foundation or basic architecture upon which other task areas are based: hazard analyses, performance measures, and risk indicator design. To carry out these other tasks, models may need to be developed using the basic architecture of the Air Carrier Operations System Model (ACOSM). Since ACOSM encompasses various areas of air-carrier operations and can be used to address different task areas with differing but interrelated objectives, the modeling needs are broad. A literature search was conducted to identify and analyze the existing models that may be applicable for pursuing the task areas in ACOSM. The intent of the literature search was not necessarily to identify a specific model that can be directly used, but rather to identify relevant ones that have similarities with the processes and activities defined within ACOSM. Such models may provide useful inputs and insights in structuring ACOSM models. ACOSM simulates processes and activities in air-carrier operation, but, in a general framework, it has similarities with other industries where attention also has been paid to hazard analyses, emphasizing risk management, and in designing risk indicators. To assure that efforts in other industries are adequately considered, the literature search includes publications from other industries, e.g., chemical, nuclear, and process industries. This report discusses the literature search, the relevant methods identified and provides a preliminary assessment of their use in developing the models needed for the ACOSM task areas. A detailed assessment of the models has not been made. Defining those applicable for ACOSM will need further analyses of both the models and tools identified. The report is organized in four chapters

  15. Excess Sodium Tetraphenylborate and Intermediates Decomposition Studies

    Energy Technology Data Exchange (ETDEWEB)

    Barnes, M.J. [Westinghouse Savannah River Company, AIKEN, SC (United States); Peterson , R.A.

    1998-04-01

    The stability of excess amounts of sodium tetraphenylborate (NaTPB) in the In-Tank Precipitation (ITP) facility depends on a number of variables. Concentration of palladium, initial benzene, and sodium ion as well as temperature provide the best opportunities for controlling the decomposition rate. This study examined the influence of these four variables on the reactivity of palladium-catalyzed sodium tetraphenylborate decomposition. Also, single effects tests investigated the reactivity of simulants with continuous stirring and nitrogen ventilation, with very high benzene concentrations, under washed sodium concentrations, with very high palladium concentrations, and with minimal quantities of excess NaTPB. These tests showed the following.The testing demonstrates that current facility configuration does not provide assured safety of operations relative to the hazards of benzene (in particular to maintain the tank headspace below 60 percent of the lower flammability limit (lfl) for benzene generation rates of greater than 7 mg/(L.h)) from possible accelerated reaction of excess NaTPB. Current maximal operating temperatures of 40 degrees C and the lack of protection against palladium entering Tank 48H provide insufficient protection against the onset of the reaction. Similarly, control of the amount of excess NaTPB, purification of the organic, or limiting the benzene content of the slurry (via stirring) and ionic strength of the waste mixture prove inadequate to assure safe operation.

  16. Excess Sodium Tetraphenylborate and Intermediates Decomposition Studies

    International Nuclear Information System (INIS)

    Barnes, M.J.; Peterson, R.A.

    1998-04-01

    The stability of excess amounts of sodium tetraphenylborate (NaTPB) in the In-Tank Precipitation (ITP) facility depends on a number of variables. Concentration of palladium, initial benzene, and sodium ion as well as temperature provide the best opportunities for controlling the decomposition rate. This study examined the influence of these four variables on the reactivity of palladium-catalyzed sodium tetraphenylborate decomposition. Also, single effects tests investigated the reactivity of simulants with continuous stirring and nitrogen ventilation, with very high benzene concentrations, under washed sodium concentrations, with very high palladium concentrations, and with minimal quantities of excess NaTPB. These tests showed the following.The testing demonstrates that current facility configuration does not provide assured safety of operations relative to the hazards of benzene (in particular to maintain the tank headspace below 60 percent of the lower flammability limit (lfl) for benzene generation rates of greater than 7 mg/(L.h)) from possible accelerated reaction of excess NaTPB. Current maximal operating temperatures of 40 degrees C and the lack of protection against palladium entering Tank 48H provide insufficient protection against the onset of the reaction. Similarly, control of the amount of excess NaTPB, purification of the organic, or limiting the benzene content of the slurry (via stirring) and ionic strength of the waste mixture prove inadequate to assure safe operation

  17. Improved condenser design and condenser-fan operation for air-cooled chillers

    International Nuclear Information System (INIS)

    Yu, F.W.; Chan, K.T.

    2006-01-01

    Air-cooled chillers traditionally operate under head pressure control via staging constant-speed condenser fans. This causes a significant drop in their coefficient of performance (COP) at part load or low outdoor temperatures. This paper describes how the COP of these chillers can be improved by a new condenser design, using evaporative pre-coolers and variable-speed fans. A thermodynamic model for an air-cooled screw-chiller was developed, within which the condenser component considers empirical equations showing the effectiveness of an evaporative pre-cooler in lowering the outdoor temperature in the heat-rejection process. The condenser component also contains an algorithm to determine the number and speed of the condenser fans staged at any given set point of condensing temperature. It is found that the chiller's COP can be maximized by adjusting the set point based on any given chiller load and wet-bulb temperature of the outdoor air. A 5.6-113.4% increase in chiller COP can be achieved from the new condenser design and condenser fan operation. This provides important insights into how to develop more energy-efficient air-cooled chillers

  18. Operability Test Report for 241-T compressed air system and heat pump

    International Nuclear Information System (INIS)

    Freeman, R.D.

    1995-02-01

    This Operability Test Report (OTR) documents the results of functional testing performed on the operating parameters of the 241-T-701 Compressed Air System. The System was successfully installed and tested per work package 2W-92-01172

  19. The study of operating an air conditioning system using Maisotsenko-Cycle

    Science.gov (United States)

    Khan, Mohammad S.; Tahan, Sami; Toufic El-Achkar, Mohamad; Abou Jamus, Saleh

    2018-03-01

    The project aims to design and build an air conditioning system that runs on the Maisotsenko cycle. The system is required to condition and cool down ambient air for a small residential space with the reduction in the use of electricity and eliminating the use of commercial refrigerants. This project can operate at its optimum performance in remote areas like oil diggers and other projects that run in the desert or any site that would not have a very high relative humidity level. The Maisotsenko cycle is known as the thermodynamic concept that captures energy from the air by using the psychometric renewable energy available in the latent heat in water evaporating in air. The heat and mass exchanger design was based on choosing a material that would-be water resistant and breathable, which was found to be layers of cardboard placed on top of each other and thus creating channels for air to pass through. Aiming for this design eliminates any high power electrical equipment such as compressors, condensers and evaporators that would be used in an AC system with the exception of a 600 W blower and a 10 W fan, thus making it a more environmentally friendly project. Moreover, the project is limited by the ambient temperature and humidity, as the model operates at an optimum when the relative humidity is lower.

  20. The Twelfth US Air Force. Tactical and Operational Innovations in the Mediterranean Theater of Operations, 1943-1944

    Science.gov (United States)

    2007-02-01

    Unicorn , Battler, At- tacker, Hunter, and Stalker were used to augment the aircraft operating from Sicilian airfields and conducted 713 sorties...success.103 The Fifth Army G­2 estimated that heavy German personnel casualties, dam­ aged equipment, and loss of supplies resulted in a significant...prevent enemy air penetration of the assault beaches and convoys, defensive air patrols were used to provide three different layers of cover- age . The

  1. Operational readiness of filtered air discharge monitoring systems

    International Nuclear Information System (INIS)

    Lafortune, J.F.; Jamieson, T.J.

    1993-08-01

    An assessment of the operational readiness of the Filtered Air Discharge (FAD) Stack Monitoring systems, installed in Canadian CANDU nuclear power plants, was performed in this project. Relevant Canadian and foreign standards and regulatory requirements have been reviewed and documentation on FAD stack monitoring system design, operation, testing and maintenance have been assessed to identify likely causes and potential failures of FAD stack monitoring systems and their components under both standby and accident conditions. Recommendations have also been provided in this report for design and performance review guidelines for CANDU stations. A case study of the FAD stack monitoring system at Pickering NGS is also documented in this report

  2. Operational air sampling report

    International Nuclear Information System (INIS)

    Lyons, C.L.

    1994-03-01

    Nevada Test Site vertical shaft and tunnel events generate beta/gamma fission products. The REECo air sampling program is designed to measure these radionuclides at various facilities supporting these events. The current testing moratorium and closure of the Decontamination Facility has decreased the scope of the program significantly. Of the 118 air samples collected in the only active tunnel complex, only one showed any airborne fission products. Tritiated water vapor concentrations were very similar to previously reported levels. The 206 air samples collected at the Area-6 decontamination bays and laundry were again well below any Derived Air Concentration calculation standard. Laboratory analyses of these samples were negative for any airborne fission products

  3. Tritium Room Air Monitor Operating Experience Review

    Energy Technology Data Exchange (ETDEWEB)

    L. C. Cadwallader; B. J. Denny

    2008-09-01

    Monitoring the breathing air in tritium facility rooms for airborne tritium is a radiological safety requirement and a best practice for personnel safety. Besides audible alarms for room evacuation, these monitors often send signals for process shutdown, ventilation isolation, and cleanup system actuation to mitigate releases and prevent tritium spread to the environment. Therefore, these monitors are important not only to personnel safety but also to public safety and environmental protection. This paper presents an operating experience review of tritium monitor performance on demand during small (1 mCi to 1 Ci) operational releases, and intentional airborne inroom tritium release tests. The tritium tests provide monitor operation data to allow calculation of a statistical estimate for the reliability of monitors annunciating in actual tritium gas airborne release situations. The data show a failure to operate rate of 3.5E-06/monitor-hr with an upper bound of 4.7E-06, a failure to alarm on demand rate of 1.4E-02/demand with an upper bound of 4.4E-02, and a spurious alarm rate of 0.1 to 0.2/monitor-yr.

  4. Air Force Military Personnel Entitlement Pay in Support of Contingency Operations

    Science.gov (United States)

    2010-08-23

    Report No. A-2006-0067- FFM , “Military Pay for Operation Enduring Freedom/Operation Iraqi Freedom Active Components,” April 5, 2006 U.S. Army Audit...Agency Report No. A-2006-0079- FFM , “Material Weakness Closeout on Line of Duty and Incapacitation Pay,” March 8, 2006 22B22BAir Force Air Force

  5. Commissioning and operating experience of compressed air system of a reprocessing plant (Paper No. 5.10)

    International Nuclear Information System (INIS)

    Nair, M.K.T.; Bajpai, D.D.; Mishra, A.K.; Kulkarni, H.B.; Raje, R.V.; Rajeshwar, S.

    1992-01-01

    Compressed air system is one of the most important utility systems, required in the continued operation of a radiochemical plant. Moisture and oil free compressed air is used in large scale for process control and process operations in reprocessing plants. Commissioning and operating experience of this system is described in detail, to indicate the importance of the system in the overall design and operation of such chemical plant. (author). 1 tab

  6. Durability and regeneration of activated carbon air-cathodes in long-term operated microbial fuel cells

    Science.gov (United States)

    Zhang, Enren; Wang, Feng; Yu, Qingling; Scott, Keith; Wang, Xu; Diao, Guowang

    2017-08-01

    The performance of activated carbon catalyst in air-cathodes in microbial fuel cells was investigated over one year. A maximum power of 1722 mW m-2 was produced within the initial one-month microbial fuel cell operation. The air-cathodes produced a maximum power >1200 mW m-2 within six months, but gradually became a limiting factor for the power output in prolonged microbial fuel cell operation. The maximum power decreased by 55% when microbial fuel cells were operated over one year due to deterioration in activated carbon air-cathodes. While salt/biofilm removal from cathodes experiencing one-year operation increased a limiting performance enhancement in cathodes, a washing-drying-pressing procedure could restore the cathode performance to its original levels, although the performance restoration was temporary. Durable cathodes could be regenerated by re-pressing activated carbon catalyst, recovered from one year deteriorated air-cathodes, with new gas diffusion layer, resulting in ∼1800 mW m-2 of maximum power production. The present study indicated that activated carbon was an effective catalyst in microbial fuel cell cathodes, and could be recovered for reuse in long-term operated microbial fuel cells by simple methods.

  7. Reduction of NOx emission in tangential fired - furnace by changing the, mode of operation

    International Nuclear Information System (INIS)

    Chudnovsky, B.; Talanker, A.; Levin, L.; Kahana, S

    1998-01-01

    The present work analyses tile results of tests on 575 MW units with tangential firing furnace arrangement in sub-stoichiometric combustion. Tangential firing provides good conditions for implementing sub-stoichiometric combustion owing to the delivery scheme of pulverized coal and air. The furnace was tested in several different modes of operation (Over Fire Air, Bunkers Out Of Service, Excess air, Tilt etc.) to achieve low cost NOx reduction. Actual performance data are presented based on experiments made on lEC's boiler in M.D. 'B' power station

  8. 14 CFR Appendix A to Part 136 - Special Operating Rules for Air Tour Operators in the State of Hawaii

    Science.gov (United States)

    2010-01-01

    ... Operators in the State of Hawaii A Appendix A to Part 136 Aeronautics and Space FEDERAL AVIATION... Appendix A to Part 136—Special Operating Rules for Air Tour Operators in the State of Hawaii Section 1... flights conducted in the State of Hawaii under 14 CFR parts 91, 121, and 135. This appendix does not apply...

  9. Modeling the Environmental Impact of Air Traffic Operations

    Science.gov (United States)

    Chen, Neil

    2011-01-01

    There is increased interest to understand and mitigate the impacts of air traffic on the climate, since greenhouse gases, nitrogen oxides, and contrails generated by air traffic can have adverse impacts on the climate. The models described in this presentation are useful for quantifying these impacts and for studying alternative environmentally aware operational concepts. These models have been developed by leveraging and building upon existing simulation and optimization techniques developed for the design of efficient traffic flow management strategies. Specific enhancements to the existing simulation and optimization techniques include new models that simulate aircraft fuel flow, emissions and contrails. To ensure that these new models are beneficial to the larger climate research community, the outputs of these new models are compatible with existing global climate modeling tools like the FAA's Aviation Environmental Design Tool.

  10. What is the optimal management of an intra-operative air leak in a colorectal anastomosis?

    Science.gov (United States)

    Mitchem, J B; Stafford, C; Francone, T D; Roberts, P L; Schoetz, D J; Marcello, P W; Ricciardi, R

    2018-02-01

    An airtight anastomosis on intra-operative leak testing has been previously demonstrated to be associated with a lower risk of clinically significant postoperative anastomotic leak following left-sided colorectal anastomosis. However, to date, there is no consistently agreed upon method for management of an intra-operative anastomotic leak. Therefore, we powered a noninferiority study to determine whether suture repair alone was an appropriate strategy for the management of an intra-operative air leak. This is a retrospective cohort analysis of prospectively collected data from a tertiary care referral centre. We included all consecutive patients with left-sided colorectal or ileorectal anastomoses and evidence of air leak during intra-operative leak testing. Patients were excluded if proximal diversion was planned preoperatively, a pre-existing proximal diversion was present at the time of surgery or an anastomosis was ultimately unable to be completed. The primary outcome measure was clinically significant anastomotic leak, as defined by the Surgical Infection Study Group at 30 days. From a sample of 2360 patients, 119 had an intra-operative air leak during leak testing. Sixty-eight patients underwent suture repair alone and 51 underwent proximal diversion or anastomotic reconstruction. The clinically significant leak rate was 9% (6/68; 95% CI: 2-15%) in the suture repair alone arm and 0% (0/51) in the diversion or reconstruction arm. Suture repair alone does not meet the criteria for noninferiority for the management of intra-operative air leak during left-sided colorectal anastomosis. Further repair of intra-operative air leak by suture repair alone should be reconsidered given these findings. Colorectal Disease © 2017 The Association of Coloproctology of Great Britain and Ireland.

  11. The electrolyte challenge for a direct methanol-air polymer electrolyte fuel cell operating at temperatures up to 200 C

    Science.gov (United States)

    Savinell, Robert; Yeager, Ernest; Tryk, Donald; Landau, Uziel; Wainright, Jesse; Gervasio, Dominic; Cahan, Boris; Litt, Morton; Rogers, Charles; Scherson, Daniel

    1993-01-01

    Novel polymer electrolytes are being evaluated for use in a direct methanol-air fuel cell operating at temperatures in excess of 100 C. The evaluation includes tests of thermal stability, ionic conductivity, and vapor transport characteristics. The preliminary results obtained to date indicate that a high temperature polymer electrolyte fuel cell is feasible. For example, Nafion 117 when equilibrated with phosphoric acid has a conductivity of at least 0.4 Omega(exp -1)cm(exp -1) at temperatures up to 200 C in the presence of 400 torr of water vapor and methanol vapor cross over equivalent to 1 mA/cm(exp 2) under a one atmosphere methanol pressure differential at 135 C. Novel polymers are also showing similar encouraging results. The flexibility to modify and optimize the properties by custom synthesis of these novel polymers presents an exciting opportunity to develop an efficient and compact methanol fuel cell.

  12. Turning Point: Operation Allied Force and the Allure of Air Power

    Science.gov (United States)

    2014-06-13

    Air Force Base in Nevada, from “a windowless bunker, lit by constantly flickering computer screens,” a Predator drone operator zoomed in on the...how the Army would mitigate risks to the Apaches by using artillery to suppress Serb air defenses before the Apaches went on their deep strike...conflict.” 162Clark, Waging Modern War, 236-7. 163Drozdiak, A22. 164To mitigate alliance member concerns, NATO did not officially refer to

  13. Operating systems in the air transportation environment.

    Science.gov (United States)

    Cherry, G. W.

    1971-01-01

    Consideration of the problems facing air transport at present, and to be expected in the future. In the Northeast Corridor these problems involve community acceptance, airway and airport congestion and delays, passenger acceptance, noise reduction, and improvements in low-density short-haul economics. In the development of a superior short-haul operating system, terminal-configured vs cruise-configured vehicles are evaluated. CTOL, STOL, and VTOL aircraft of various types are discussed. In the field of noise abatement, it is shown that flight procedural techniques are capable of supplementing ?quiet engine' technology.

  14. An Analysis of Skill Requirements for Operators of Amphibious Air Cushion Vehicles (ACVs).

    Science.gov (United States)

    McKnight, A. James; And Others

    This report describes the skills required in the operation of an amphibious air cushion vehicle (ACV) in Army tactical and logistic missions. The research involved analyzing ACV characteristics, operating requirements, environmental effects, and results of a simulation experiment. The analysis indicates that ACV operation is complicated by an…

  15. Assessment of operating room air distribution in a mobile hospital: field experiment based on VDI 2167

    NARCIS (Netherlands)

    Forejt, L.; Drkal, F.; Hensen, J.L.M.; Seppänen, O.; Säteri, J.

    2007-01-01

    Air distribution in mobile operating room was assessed according to the recent acceptance test (VDI, 2004 [1]). This standard presents a simple and uniform validation procedure of operating room air distribution systems. Therefore it was applied as an objective method for evaluating performance of

  16. Air emission points for facilities in Iowa with operating permits for Title V of the Federal Clean Air Act_considered MAJOR permits

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Air emission points for facilities in Iowa with operating permits for Title V of the Federal Clean Air Act, considered "major" permits. Also includes emission points...

  17. Emission of hydrocarbons and NO{sub x} at low levels of excess air in CFB; Emissioner av kolvaeten och NO{sub x} vid laaga luftoeverskott i CFB

    Energy Technology Data Exchange (ETDEWEB)

    Schuster, R [TPS Termiska Processer AB, Nykoeping (Sweden)

    1995-06-01

    Low NO{sub x} operation at low excess air levels heighten the risk of increasing the level of hazardous and polluting emissions from the boiler. These emissions are mainly of two types, greenhouse gases and the mutageneous compounds. The aim of this project has been to show which types of emissions and their correlation you can expect when firing a CFB at low excess air levels. Results: The NO{sub x} emission decreases asymptotically with increased CO-level. High load gives higher NO{sub x} -emissions. There is no significant difference in average NO{sub x} value between wood fuel and RDF-mix. The total hydrocarbon (THC) emission level increases exponentially with increased CO{sub l}evel. There was no significant difference between wood and RDF-mix. Measurements of NO{sub x}, O2, CO (dry gas) and THC were made each second. The measurements of light hydrocarbons (VOC) showed only methane and ethene, both with a good correlation to CO. Below 1000 ppm of CO there is practically no ethene. Above 1000-2000 ppm of CO there is a rapidly increasing emission of ethene. The emission levels at given CO-level are influenced by the furnace temperature. The POM, PNA and Ames test analysis showed good correlation with CO and THC. The results indicate an emission increase at about 200-500 ppm of CO and 10-20 ppm of THC. Dioxin was measured on three occasions with RDF-mix as fuel. The measurements showed an increase of dioxin emission at increased THC-emission. The supply of ammonia, into the flue gas before the cyclones, gave no significant change in hydrocarbon or CO-emission levels. CO, THC and Ames Test are probably good indicators of environmental hazardous compounds. The amount of mutageneous compounds are in general only increased when a certain level of CO is reached. 6 refs, 45 figs, 5 tabs, 7 appendices

  18. 78 FR 44873 - Pilot Certification and Qualification Requirements for Air Carrier Operations; Correction

    Science.gov (United States)

    2013-07-25

    ...-0100; Amdt. Nos. 61-130A] RIN 2120-AJ67 Pilot Certification and Qualification Requirements for Air... to create new certification and qualification requirements for pilots in air carrier operations. This... . SUPPLEMENTARY INFORMATION: Background On July 15, 2013, the FAA published a final rule entitled, ``Pilot...

  19. Relationships between air swallowing, intragastric air, belching and gastro-oesophageal reflux

    NARCIS (Netherlands)

    Bredenoord, AJ; Weusten, BLAM; Timmer, R; Akkermans, LMA; Smout, AJPM

    Background: With each swallow a certain amount of air is transported to the stomach. The stomach protects itself against excessive distention by swallowed air through belching (gas reflux). The mechanism of belching (transient lower oesophageal sphincter relaxation) is also one of the mechanisms

  20. Relationships between air swallowing, intragastric air, belching and gastro-oesophageal reflux

    NARCIS (Netherlands)

    Bredenoord, A. J.; Weusten, B. L. A. M.; Timmer, R.; Akkermans, L. M. A.; Smout, A. J. P. M.

    2005-01-01

    BACKGROUND: With each swallow a certain amount of air is transported to the stomach. The stomach protects itself against excessive distention by swallowed air through belching (gas reflux). The mechanism of belching (transient lower oesophageal sphincter relaxation) is also one of the mechanisms

  1. Towards a performance assessment methodology using computational simulation for air distribution system designs in operating rooms

    NARCIS (Netherlands)

    Melhado, M.D.A.

    2012-01-01

    One of the important performance requirements for an air distribution system for an operating room (OR) is to provide good indoor environmental conditions in which to perform operations. Important conditions in this respect relate to the air quality and to the thermal conditions for the surgical

  2. A discussion paper on indoor air quality investigations of houses used for marijuana grow operations

    Energy Technology Data Exchange (ETDEWEB)

    Salares, V.; Dyck, M. [Canada Mortgage and Housing Corp., Ottawa, ON (Canada)

    2007-03-15

    This paper explored issues and potential solutions to the increasing incidence of indoor residential marijuana grow operations (MGOs) in Canada. A study was conducted in which as small number of MGO houses were investigated to better understand the physical damages and the environmental contamination sustained by the houses. Indoor air quality was examined along with mold growth resulting from excessive moisture. This report identified safety issues and provided a list of recommendations for rehabilitation of the houses. Detailed procedures for clean-up were also presented. Alterations made to accommodate ventilation equipment for the grow areas were noted in most houses. Other evidence of alteration were disconnected heating ducts, addition of wiring, electrical assemblies and electrical panels that had been tampered with. Since most of the chemical containers had been removed prior to testing, the chemical component of MGOs will be the subject of a future study. The following issues of importance were highlighted during the study: (1) a nationwide harmonization of remediation requirements, (2) guidelines for mortgage lenders, (3) qualified contractors, standard protocol, (4) assessment of the extent of contamination, (5) prevention of unnecessary damage post-detection, and (6) record keeping. 3 refs.

  3. 40 CFR 57.304 - Bypass, excess emissions and malfunctions.

    Science.gov (United States)

    2010-07-01

    ... (performance level of interim constant controls) or § 57.303 (plantwide emission limitation) of this subpart... limitation, as well as the operating data, documents, and calculations used in determining the magnitude of the excess emissions; (3) Time and duration of the excess emissions; (4) Identity of the equipment...

  4. Operational experience of air washer based ventilation system for power conditioning system of Indus-2

    International Nuclear Information System (INIS)

    Pandey, R.M.; Baghel, S.L.; Parate, J.K.; Ahlawat, Sandeep; Rawlani, B.K.; Chouksey, Sanjay

    2015-01-01

    Indus-2 Synchrotron Accelerator requires high quality conditioned uninterrupted AC mains power for their smooth and reliable operation. Three units of 1670 kVA and one unit of 1100 kVA capacity rotary uninterruptible power conditioning systems (UPS) were installed and commissioned. These UPS units require dust free and cool ambient conditions for smooth operation. In order to meet the ventilation requirements, an evaporative cooling system of 80000 cubic meter/hour capacity with filtration units was designed, installed and commissioned in February 2011 and is operational on round-the-clock basis. Evaporative cooling scheme was chosen as has various advantages over a refrigerated system like lower initial capital costs, lower energy usage, lower running costs, less greenhouse gas and it does not contribute to ozone depletion. The ventilation system filters the environment air in stages up to 5 micron level and being conditioned with an automatic controlled soft water circulating system with cooling pads. An instrumentation and control scheme is included in the system to provide the automation requirements for operating 24 x 7 through the year. All the mechanical, hydraulic and electrical devices are maintained by providing preventive maintenance work without affecting the accelerator machine operation. Availability and reliability of the system was analysed based on the failure data. In Year 2014, the ventilation system was upgraded to accommodate standby blower unit, coupling unit and improved quality of supply air with new air conditioning devices. The control panel monitors the condition of air in the UPS hall and maintainsup to 28°C air temperature and 85% maximum relative humidity in round-the clock shift with more than 98% operational reliability. In this paper, we present design philosophy, installation, instrumentation, testing, operation experience and availability of the ventilation system for Power Conditioning System, Indus complex. (author)

  5. Second harmonic generation study of malachite green adsorption at the interface between air and an electrolyte solution: observing the effect of excess electrical charge density at the interface.

    Science.gov (United States)

    Song, Jinsuk; Kim, Mahn Won

    2010-03-11

    Understanding the differential adsorption of ions at the interface of an electrolyte solution is very important because it is closely related, not only to the fundamental aspects of biological systems, but also to many industrial applications. We have measured the excess interfacial negative charge density at air-electrolyte solution interfaces by using resonant second harmonic generation of oppositely charged probe molecules. The excess charge density increased with the square root of the bulk electrolyte concentration. A new adsorption model that includes the electrostatic interaction between adsorbed molecules is proposed to explain the measured adsorption isotherm, and it is in good agreement with the experimental results.

  6. Molecular simulation of excess isotherm and excess enthalpy change in gas-phase adsorption.

    Science.gov (United States)

    Do, D D; Do, H D; Nicholson, D

    2009-01-29

    We present a new approach to calculating excess isotherm and differential enthalpy of adsorption on surfaces or in confined spaces by the Monte Carlo molecular simulation method. The approach is very general and, most importantly, is unambiguous in its application to any configuration of solid structure (crystalline, graphite layer or disordered porous glass), to any type of fluid (simple or complex molecule), and to any operating conditions (subcritical or supercritical). The behavior of the adsorbed phase is studied using the partial molar energy of the simulation box. However, to characterize adsorption for comparison with experimental data, the isotherm is best described by the excess amount, and the enthalpy of adsorption is defined as the change in the total enthalpy of the simulation box with the change in the excess amount, keeping the total number (gas + adsorbed phases) constant. The excess quantities (capacity and energy) require a choice of a reference gaseous phase, which is defined as the adsorptive gas phase occupying the accessible volume and having a density equal to the bulk gas density. The accessible volume is defined as the mean volume space accessible to the center of mass of the adsorbate under consideration. With this choice, the excess isotherm passes through a maximum but always remains positive. This is in stark contrast to the literature where helium void volume is used (which is always greater than the accessible volume) and the resulting excess can be negative. Our definition of enthalpy change is equivalent to the difference between the partial molar enthalpy of the gas phase and the partial molar enthalpy of the adsorbed phase. There is no need to assume ideal gas or negligible molar volume of the adsorbed phase as is traditionally done in the literature. We illustrate this new approach with adsorption of argon, nitrogen, and carbon dioxide under subcritical and supercritical conditions.

  7. Death Spiral: Luftwaffe Airlift Training, Operation Stosser, and Lessons for the Mordern U.S. Air Force

    Science.gov (United States)

    2015-05-22

    maintaining operational maneuver across strategic distances (direct-delivery, air refueling) requires training aircrews to operate while protecting ...Morzik, "German Air Force Airlift Operations," 142; E. R. Hooten, Eagle in Flames: The Fall ofthe Luftwaffe (London: Arms and Armour Press, 1997), 224...208-209. 106John Toland, Battle: The Story ofthe Bulge (New York, NY: Random House , 1959), 44-45; Post-flight calc.ulations revealed winds at the

  8. 75 FR 62639 - Air Ambulance and Commercial Helicopter Operations, Part 91 Helicopter Operations, and Part 135...

    Science.gov (United States)

    2010-10-12

    ... helicopter air ambulance operators implement a safety management system program that includes sound risk... partially address NTSB Safety Recommendation A-09-89 regarding the implementation of sound risk management... documents. Authority for This Rulemaking The FAA's authority to issue rules on aviation safety is found in...

  9. State dependent pseudo-resonances and excess noise

    OpenAIRE

    Papoff, F.; D'Alessandro, G.; Oppo, G.Luca

    2008-01-01

    We show that strong response to nonresonant modulations and excess noise are state dependent in generic nonlinear systems; i.e., they affect some output states but are absent from others. This is demonstrated in complex Swift-Hohenberg models relevant to optics, where it is caused by the non-normality of the linearized stability operators around selected output states, even though the cavity modes are orthogonal. In particular, we find the effective parameters that control excess noise and th...

  10. Neuro-optimal operation of a variable air volume HVAC and R system

    International Nuclear Information System (INIS)

    Ning Min; Zaheeruddin, M.

    2010-01-01

    Low operational efficiency especially under partial load conditions and poor control are some reasons for high energy consumption of heating, ventilation, air conditioning and refrigeration (HVAC and R) systems. To improve energy efficiency, HVAC and R systems should be efficiently operated to maintain a desired indoor environment under dynamic ambient and indoor conditions. This study proposes a neural network based optimal supervisory operation strategy to find the optimal set points for chilled water supply temperature, discharge air temperature and VAV system fan static pressure such that the indoor environment is maintained with the least chiller and fan energy consumption. To achieve this objective, a dynamic system model is developed first to simulate the system behavior under different control schemes and operating conditions. A multi-layer feed forward neural network is constructed and trained in unsupervised mode to minimize the cost function which is comprised of overall energy cost and penalty cost when one or more constraints are violated. After training, the network is implemented as a supervisory controller to compute the optimal settings for the system. Simulation results show that compared to the conventional night reset operation scheme, the optimal operation scheme saves around 10% energy under full load condition and 19% energy under partial load conditions.

  11. THE REMOTE AND MOBILE AIR TRAFFIC CONTROL TOWER AND ITS POSSIBLE APPLICATION TO THE OPERATIONAL AREA

    Directory of Open Access Journals (Sweden)

    Tímea VAS

    2014-10-01

    Full Text Available The concept of remote and mobile Air Traffic Control Tower (ATC TWR and its development has started in Europe, Australia and also in the USA, in order to improve the efficiency of Air Traffic Management (ATM systems in terms of air transportation safety. These new technologies are applicable in many countries in peace time, but on mobility reasons these are promoted to achieve commitments in the operational area. This article describes the devices and range of equipment of mobile and remote tower, and their specifications, which can even serve a medium sized airport, furthermore examines, whether how can those provide the air traffic services at an operational airfield.

  12. Influence of in-plant air pollution control measures on power plant and system operation

    International Nuclear Information System (INIS)

    Kurten, H.

    1990-01-01

    The burning of fossil fuels causes the emission of air pollutants which have harmful environmental impact. Consequently many nations have in the last few years established regulations for air pollution control and have initiated the development and deployment of air pollution control systems in power plants. The paper describes the methods used for reducing particulate, SO 2 and NO x emissions, their application as backfit systems and in new plants, the power plant capacity equipped with such systems in the Federal Republic of Germany and abroad and the additional investment and operating costs incurred. It is to be anticipated that advanced power plant designs will produce lower pollutant emissions and less waste at enhanced efficiency levels. A comparison with power generation in nuclear power plants completes the first part of the paper. This paper covers the impact of the above-mentioned air pollution control measures on unit commitment in daily operation

  13. Reduction of excess sludge production using mechanical disintegration devices.

    Science.gov (United States)

    Strünkmann, G W; Müller, J A; Albert, F; Schwedes, J

    2006-01-01

    The usability of mechanical disintegration techniques for the reduction of excess sludge production in the activated sludge process was investigated. Using three different disintegration devices (ultrasonic homogeniser, stirred media mill, high pressure homogeniser) and different operational parameters of the disintegration, the effect of mechanical disintegration on the excess sludge production and on the effluent quality was studied within a continuously operated, laboratory scale wastewater treatment system with pre-denitrification. Depending on the operational conditions and the disintegration device used, a reduction of excess sludge production of up to 70% was achieved. A combination of mechanical disintegration with a membrane bioreactor process with high sludge age is more energy effective concerning reduction of sludge production than with a conventional activated sludge process at lower sludge ages. Depending on the disintegration parameters, the disintegration has no, or only minor, negative effect on the soluble effluent COD and on the COD-removal capacity of the activated sludge process. Nitrogen-removal was slightly deteriorated by the disintegration, whereas the system used was not optimised for nitrogen removal before disintegration was implemented.

  14. EVALUATION OF PROPYLENE CARBONATE IN AIR LOGISTICS CENTER (ALC) DEPAINTING OPERATIONS

    Science.gov (United States)

    This report summarizes a two-phase, laboratory-scale screening study that evaluated solvent blends containing propylene carbonate (PC) as a potential replacement for methyl ethyl ketone (MEK) in aircraft radome depainting operations. The study was conducted at Oklahoma City Air L...

  15. Installation of PMV Operation Program in DDC Controller and Air Conditioning Control Using PMV Directly as Set Point

    Science.gov (United States)

    Haramoto, Ken-Ichi

    In general, air conditioning control in a building is operated mainly by indoor air temperature control. Although the operators of the machine in the building accepted a claim for indoor air temperature presented by the building inhabitants, the indoor conditions have been often too cool or warm. Therefore, in an attempt to create better thermal environments, the author paid attention to the PMV that is a thermal comfort index. And then, the possibility of air conditioning control using the PMV directly as the set point was verified by employing actual equipment in an air conditioning testing room and an office building. Prior to the execution of this control, the operation program of the PMV was installed in a DDC controller for the air conditioning control. And information from indoor sensors and so on was inputted to the controller, and the computed PMV was used as the feedback variable.

  16. On-line diagnostic techniques for air-operated control valves based on time series analysis

    International Nuclear Information System (INIS)

    Ito, Kenji; Matsuoka, Yoshinori; Minamikawa, Shigeru; Komatsu, Yasuki; Satoh, Takeshi.

    1996-01-01

    The objective of this research is to study the feasibility of applying on-line diagnostic techniques based on time series analysis to air-operated control valves - numerous valves of the type which are used in PWR plants. Generally the techniques can detect anomalies by failures in the initial stages for which detection is difficult by conventional surveillance of process parameters measured directly. However, the effectiveness of these techniques depends on the system being diagnosed. The difficulties in applying diagnostic techniques to air-operated control valves seem to come from the reduced sensitivity of their response as compared with hydraulic control systems, as well as the need to identify anomalies in low level signals that fluctuate only slightly but continuously. In this research, simulation tests were performed by setting various kinds of failure modes for a test valve with the same specifications as of a valve actually used in the plants. Actual control signals recorded from an operating plant were then used as input signals for simulation. The results of the tests confirmed the feasibility of applying on-line diagnostic techniques based on time series analysis to air-operated control valves. (author)

  17. Effects of operating conditions and fuel properties on emission performance and combustion efficiency of a swirling fluidized-bed combustor fired with a biomass fuel

    International Nuclear Information System (INIS)

    Kuprianov, Vladimir I.; Kaewklum, Rachadaporn; Chakritthakul, Songpol

    2011-01-01

    This work reports an experimental study on firing 80 kg/h rice husk in a swirling fluidized-bed combustor (SFBC) using an annular air distributor as the swirl generator. Two NO x emission control techniques were investigated in this work: (1) air staging of the combustion process, and (2) firing rice husk as moisturized fuel. In the first test series for the air-staged combustion, CO, NO and C x H y emissions and combustion efficiency were determined for burning 'as-received' rice husk at fixed excess air of 40%, while secondary-to-primary air ratio (SA/PA) was ranged from 0.26 to 0.75. The effects of SA/PA on CO and NO emissions from the combustor were found to be quite weak, whereas C x H y emissions exhibited an apparent influence of air staging. In the second test series, rice husks with the fuel-moisture content of 8.4% to 35% were fired at excess air varied from 20% to 80%, while the flow rate of secondary air was fixed. Radial and axial temperature and gas concentration (O 2 , CO, NO) profiles in the reactor, as well as CO and NO emissions, are discussed for the selected operating conditions. The temperature and gas concentration profiles for variable fuel quality exhibited significant effects of both fuel-moisture and excess air. As revealed by experimental results, the emission of NO from this SFBC can be substantially reduced through moisturizing rice husk, while CO is effectively mitigated by injection of secondary air into the bed splash zone, resulting in a rather low emission of CO and high (over 99%) combustion efficiency of the combustor for the ranges of operating conditions and fuel properties.

  18. The Impact of Nonequilibrium and Equilibrium Fractionation on Two Different Deuterium Excess Definitions

    Science.gov (United States)

    Dütsch, Marina; Pfahl, Stephan; Sodemann, Harald

    2017-12-01

    The deuterium excess (d) is a useful measure for nonequilibrium effects of isotopic fractionation and can therefore provide information about the meteorological conditions in evaporation regions or during ice cloud formation. In addition to nonequilibrium fractionation, two other effects can change d during phase transitions. The first is the dependence of the equilibrium fractionation factors on temperature, and the second is the nonlinearity of the δ scale on which d is defined. The second effect can be avoided by using an alternative definition that is based on the logarithmic scale. However, in this case d is not conserved when air parcels mix, which can lead to changes without phase transitions. Here we provide a systematic analysis of the benefits and limitations of both deuterium excess definitions by separately quantifying the impact of the nonequilibrium effect, the temperature effect, the δ-scale effect, and the mixing effect in a simple Rayleigh model simulating the isotopic composition of air parcels during moist adiabatic ascent. The δ-scale effect is important in depleted air parcels, for which it can change the sign of the traditional deuterium excess in the remaining vapor from negative to positive. The alternative definition mainly reflects the nonequilibrium and temperature effect, while the mixing effect is about 2 orders of magnitude smaller. Thus, the alternative deuterium excess definition appears to be a more accurate measure for nonequilibrium effects in situations where moisture is depleted and the δ-scale effect is large, for instance, at high latitudes or altitudes.

  19. EMMA model: an advanced operational mesoscale air quality model for urban and regional environments

    International Nuclear Information System (INIS)

    Jose, R.S.; Rodriguez, M.A.; Cortes, E.; Gonzalez, R.M.

    1999-01-01

    Mesoscale air quality models are an important tool to forecast and analyse the air quality in regional and urban areas. In recent years an increased interest has been shown by decision makers in these types of software tools. The complexity of such a model has grown exponentially with the increase of computer power. Nowadays, medium workstations can run operational versions of these modelling systems successfully. Presents a complex mesoscale air quality model which has been installed in the Environmental Office of the Madrid community (Spain) in order to forecast accurately the ozone, nitrogen dioxide and sulphur dioxide air concentrations in a 3D domain centred on Madrid city. Describes the challenging scientific matters to be solved in order to develop an operational version of the atmospheric mesoscale numerical pollution model for urban and regional areas (ANA). Some encouraging results have been achieved in the attempts to improve the accuracy of the predictions made by the version already installed. (Author)

  20. Maximizing the Social Welfare of Virtual Power Players Operation in Case of Excessive Wind Power

    DEFF Research Database (Denmark)

    Faria, Pedro; Vale, Zita; Morais, Hugo

    2013-01-01

    based generation (including wind power) has caused several changes in the operation and planning of power systems and of electricity markets. Sometimes the available non-dispatchable generation is higher than the demand. This generation must be used; otherwise it is wasted if not stored or used...... that aggregates and manages the available energy resources. When facing a situation of excessive non-dispatchable generation, including wind power, real time pricing is applied in order to induce the increase of consumption so that wind curtailment is minimized. This method is especially useful when actual...... in this paper using a real 937-bus distribution network with 20.310 consumers and 548 distributed generators, some of them non-dispatchable and with must take contracts. The implemented scenario corresponds to a real day in Portuguese power system....

  1. Chemicals and excess materials disposition during deactivation as a means of pollution prevention

    International Nuclear Information System (INIS)

    Godfrey, S.D.

    1998-01-01

    This paper presents several innovative and common sense approaches to pollution prevention that have been employed during facility deactivation at the Hanford Site in South Central Washington. It also presents several pollution prevention principles applicable to other projects. Innovative pollution prevention ideas employed at the Hanford site during facility deactivation included: (1) Recycling more than 185,000 gallons of radioactively contaminated nitric acid by sending it to an operating nuclear fuels reprocessing facility in England; (2) Recycling millions of pounds of chemicals and excess materials to other industries for reuse; (3) Evaporating flush water at a low rate and discharging it into the facility exhaust air stream to avoid discharging thousands of gallons of liquid to the soil column; and (4) Decontaminating and disposing of thousands of gallons of radioactively contaminated organic solvent waste to a RCRA licensed, power-producing, commercial incinerator. Common sense pollution prevention ideas that were employed include recycling office furniture, recycling paper from office files, and redeploying tools and miscellaneous process equipment. Additional pollution prevention occurred as the facility liquid and gaseous discharge streams were deactivated. From the facilities deactivation experiences at Hanford and the ensuing efforts to disposition excess chemicals and materials, several key pollution prevention principles should be considered at other projects and facilities, especially during the operational periods of the facility's mission. These principles include: Institute pollution prevention as a fundamental requirement early in the planning stage of a project or during the operational phase of a facility's mission; Promote recognition and implementation of pollution prevention initiatives; Instill pollution prevention as a value in all participants in the project or facility work scope; Minimize the amount of chemical products and materials

  2. 75 FR 6164 - New Pilot Certification Requirements for Air Carrier Operations

    Science.gov (United States)

    2010-02-08

    .... FAA-2010-0100; Notice No. 10-02] RIN 2120-AJ67 New Pilot Certification Requirements for Air Carrier... to regulations relating to the certification of pilots conducting domestic, flag, and supplemental... qualification requirements for commercial pilot certification are adequate for engaging in such operations. The...

  3. Cooling energy efficiency and classroom air environment of a school building operated by the heat recovery air conditioning unit

    International Nuclear Information System (INIS)

    Wang, Yang; Zhao, Fu-Yun; Kuckelkorn, Jens; Liu, Di; Liu, Li-Qun; Pan, Xiao-Chuan

    2014-01-01

    The recently-built school buildings have adopted novel heat recovery ventilator and air conditioning system. Heat recovery efficiency of the heat recovery facility and energy conservation ratio of the air conditioning unit were analytically modeled, taking the ventilation networks into account. Following that, school classroom displacement ventilation and its thermal stratification and indoor air quality indicated by the CO 2 concentration have been numerically modeled concerning the effects of delivering ventilation flow rate and supplying air temperature. Numerical results indicate that the promotion of mechanical ventilation rate can simultaneously boost the dilution of indoor air pollutants and the non-uniformity of indoor thermal and pollutant distributions. Subsequent energy performance analysis demonstrates that classroom energy demands for ventilation and cooling could be reduced with the promotion of heat recovery efficiency of the ventilation facility, and the energy conservation ratio of the air conditioning unit decreases with the increasing temperatures of supplying air. Fitting correlations of heat recovery ventilation and cooling energy conservation have been presented. - Highlights: • Low energy school buildings and classroom environment. • Heat recovery facility operating with an air conditioning unit. • Displacement ventilation influenced by the heat recovery efficiency. • Energy conservation of cooling and ventilation through heat recovery. • Enhancement of classroom environment with reduction of school building energy

  4. Streamlining air import operations by trade facilitation measures

    Directory of Open Access Journals (Sweden)

    Yuri da Cunha Ferreira

    2017-12-01

    Full Text Available Global operations are subject to considerable uncertainties. Due to the Trade Facilitation Agreement that became effective in February 2017, the study of measures to streamline customs controls is urgent. This study aims to assess the impact of trade facilitation measures on import flows. An experimental study was performed in the largest cargo airport in South America through discrete-event simulation and design of experiments. Operation impacts of three trade facilitation measures are assessed on import flow by air. We shed light in the following trade facilitation measures: the use of X-ray equipment for physical inspection; increase of the number of qualified companies in the trade facilitation program; performance targets for customs officials. All trade facilitation measures used indicated potential to provide more predictability, cost savings, time reduction, and increase in security in international supply chain.

  5. Air sampling procedures to evaluate microbial contamination: a comparison between active and passive methods in operating theatres.

    Science.gov (United States)

    Napoli, Christian; Marcotrigiano, Vincenzo; Montagna, Maria Teresa

    2012-08-02

    Since air can play a central role as a reservoir for microorganisms, in controlled environments such as operating theatres regular microbial monitoring is useful to measure air quality and identify critical situations. The aim of this study is to assess microbial contamination levels in operating theatres using both an active and a passive sampling method and then to assess if there is a correlation between the results of the two different sampling methods. The study was performed in 32 turbulent air flow operating theatres of a University Hospital in Southern Italy. Active sampling was carried out using the Surface Air System and passive sampling with settle plates, in accordance with ISO 14698. The Total Viable Count (TVC) was evaluated at rest (in the morning before the beginning of surgical activity) and in operational (during surgery). The mean TVC at rest was 12.4 CFU/m3 and 722.5 CFU/m2/h for active and passive samplings respectively. The mean in operational TVC was 93.8 CFU/m3 (SD = 52.69; range = 22-256) and 10496.5 CFU/m2/h (SD = 7460.5; range = 1415.5-25479.7) for active and passive samplings respectively. Statistical analysis confirmed that the two methods correlate in a comparable way with the quality of air. It is possible to conclude that both methods can be used for general monitoring of air contamination, such as routine surveillance programs. However, the choice must be made between one or the other to obtain specific information.

  6. Air-operated valve diagnostics: requirements, programmes and experiences

    International Nuclear Information System (INIS)

    Cervilla, Remedios; Vallana, Fernando; Laporta, Jose Maria

    2014-01-01

    The aim of this paper is to present some elements in the field of air-operated valve (AOV) diagnostics from the perspective of Tecnatom, as a testing services provider in the national and international nuclear park. Throughout the following lines, we summarize the regulatory framework existing in Spain and the current practices in Spanish nuclear power plants regarding the AOV programs, the role of Tecnatom as a service provider and our testing techniques. Finally, a real test case is presented, to illustrate the value of diagnostic as predictive maintenance and early degradation detection tool. (authors)

  7. Basing the US Air Force Special Operations Forces.

    Science.gov (United States)

    1986-12-01

    Headquarters Military Airlift Command (Hq MAC/XONP), Scott AFB, IL, July 8, 1986. 2. Daskin , Mark S. " A Maximum Expected Covering Location Model: Formulation...7942 m~ I SAIR F ORME S ECI L PE DO S CHOOL’ 1 OF EMNIEERINO A E KCRAUS DEC 66 RFIT/OOLOS/MN-6 IUCLRS SIFIE F.’G1F/OI L Ehhmhmmhhhhhhl smomhmhmhhum...Ap a . %Ř ~ ,~, ~~%9~ q%%~ * % . i %%~ . ~* - out; ’-ILE Copy / AFIT/GOR/OS/86D-6 II BASING THE US AIR FORCE SPECIAL OPERATIONS FORCES THESIS Mark E

  8. Techniques for controlling air pollution from the operation of nuclear facilities. Report of a panel

    International Nuclear Information System (INIS)

    1966-01-01

    This manual is provided for the guidance of those persons or authorities who are responsible for the organization, control and operation of ventilation systems and air-cleaning installations in nuclear establishments. It is intended to generalize about existing experience in the operation of such systems at nuclear facilities including reactors and laboratories for production, use and handling of radionuclides and other toxic materials. This manual will provide designers and operators of nuclear facilities in which ventilation and air-cleaning systems are used with the factors which have to be considered to create safe working conditions inside facilities and without polluting the atmosphere or the environment to a hazardous level.

  9. Air sampling procedures to evaluate microbial contamination: a comparison between active and passive methods in operating theatres

    Directory of Open Access Journals (Sweden)

    Napoli Christian

    2012-08-01

    Full Text Available Abstract Background Since air can play a central role as a reservoir for microorganisms, in controlled environments such as operating theatres regular microbial monitoring is useful to measure air quality and identify critical situations. The aim of this study is to assess microbial contamination levels in operating theatres using both an active and a passive sampling method and then to assess if there is a correlation between the results of the two different sampling methods. Methods The study was performed in 32 turbulent air flow operating theatres of a University Hospital in Southern Italy. Active sampling was carried out using the Surface Air System and passive sampling with settle plates, in accordance with ISO 14698. The Total Viable Count (TVC was evaluated at rest (in the morning before the beginning of surgical activity and in operational (during surgery. Results The mean TVC at rest was 12.4 CFU/m3 and 722.5 CFU/m2/h for active and passive samplings respectively. The mean in operational TVC was 93.8 CFU/m3 (SD = 52.69; range = 22-256 and 10496.5 CFU/m2/h (SD = 7460.5; range = 1415.5-25479.7 for active and passive samplings respectively. Statistical analysis confirmed that the two methods correlate in a comparable way with the quality of air. Conclusion It is possible to conclude that both methods can be used for general monitoring of air contamination, such as routine surveillance programs. However, the choice must be made between one or the other to obtain specific information.

  10. Eliminate the Army and Air Force Reserves: Building a Robust National Guard to Meet 21st Century Operational Challenges

    Science.gov (United States)

    2016-04-04

    TITLE AND SUBTITLE ELIMINATE THE ARMY AND AIR FORCE RESERVES: BUILDING A ROBUST NATIONAL GUARD TO MEET 21ST CENTURY OPERATIONAL CHALLENGES 5a...STAFF COLLEGE JOINT ADVANCED WARFIGHTING SCHOOL ELIMINATE THE ARMY AND AIR FORCE RESERVES: BUILDING A ROBUST NATIONAL GUARD TO... ELIMINATE THE ARMY AND AIR FORCE RESERVES: BUILDING A ROBUST NATIONAL GUARD TO MEET 21ST CENTURY OPERATIONAL CHALLENGES by

  11. Air-processed organic tandem solar cells on glass: toward competitive operating lifetimes

    DEFF Research Database (Denmark)

    Adams, Jens; Spyropoulos, George D.; Salvador, Michael

    2015-01-01

    efficiencies of more than 10% the rather limited stability of this type of devices raises concerns towards future commercialization. The tandem concept allows for both absorbing a broader range of the solar spectrum and reducing thermalization losses. We designed an organic tandem solar cell with an inverted...... device geometry comprising environmentally stable active and charge-selecting layers. Under continuous white light irradiation, we demonstrate an extrapolated, operating lifetime in excess of one decade. We elucidate that for the current generation of organic tandem cells one critical requirement...... for long operating lifetimes consists of periodic UV light treatment. These results suggest that new material approaches towards UV-resilient active and interfacial layers may enable efficient organic tandem solar cells with lifetimes competitive with traditional inorganic photovoltaics....

  12. Incinerator performance: effects of changes in waste input and furnace operation on air emissions and residues

    DEFF Research Database (Denmark)

    Astrup, Thomas; Riber, Christian; Pedersen, Anne Juul

    2011-01-01

    Waste incineration can be considered a robust technology for energy recovery from mixed waste. Modern incinerators are generally able to maintain relatively stable performance, but changes in waste input and furnace operation may affect emissions. This study investigated how inorganic air emissions...... including ‘as-large-as-possible’ changes in furnace operation (oxygen levels, air supply and burnout level) only using normal MSW as input. The experiments showed that effects from the added waste materials were significant in relation to: air emissions (in particular As, Cd, Cr, Hg, Sb), element transfer...... coefficients, and residue composition (As, Cd, Cl, Cr, Cu, Hg, Mo, Ni, Pb, S, Sb, Zn). Changes in furnace operation could not be directly linked to changes in emissions and residues. The results outlined important elements in waste which should be addressed in relation to waste incinerator performance. Likely...

  13. Mobile laminar air flow screen for additional operating room ventilation: reduction of intraoperative bacterial contamination during total knee arthroplasty.

    Science.gov (United States)

    Sossai, D; Dagnino, G; Sanguineti, F; Franchin, F

    2011-12-01

    Surgical site infections are important complications in orthopedic surgery. A mobile laminar air flow (LAF) screen could represent a useful addition to an operating room (OR) with conventional turbulent air ventilation (12.5 air changes/h), as it could decrease the bacterial count near the operating field. The purpose of this study was to evaluate LAF efficacy at reducing bacterial contamination in the surgical area during 34 total knee arthroplasties (TKAs). The additional unit was used in 17 operations; the LAF was positioned beside the operating table between two of the surgeons, with the air flow directed towards the surgical area (wound). The whole team wore conventional OR clothing and the correct hygiene procedures and rituals were used. Bacterial air contamination (CFU/m(3)) was evaluated in the wound area in 17 operations with the LAF unit and 17 without the LAF unit. The LAF unit reduced the mean bacterial count in the wound area from 23.5 CFU/m(3) without the LAF to 3.5 CFU/m(3) with the LAF (P contamination of the wound area significantly decreased to below the accepted level for an ultraclean OR, preventing SSI infections.

  14. Air sampling methods to evaluate microbial contamination in operating theatres: results of a comparative study in an orthopaedics department.

    Science.gov (United States)

    Napoli, C; Tafuri, S; Montenegro, L; Cassano, M; Notarnicola, A; Lattarulo, S; Montagna, M T; Moretti, B

    2012-02-01

    To evaluate the level of microbial contamination of air in operating theatres using active [i.e. surface air system (SAS)] and passive [i.e. index of microbial air contamination (IMA) and nitrocellulose membranes positioned near the wound] sampling systems. Sampling was performed between January 2010 and January 2011 in the operating theatre of the orthopaedics department in a university hospital in Southern Italy. During surgery, the mean bacterial loads recorded were 2232.9 colony-forming units (cfu)/m(2)/h with the IMA method, 123.2 cfu/m(3) with the SAS method and 2768.2 cfu/m(2)/h with the nitrocellulose membranes. Correlation was found between the results of the three methods. Staphylococcus aureus was detected in 12 of 60 operations (20%) with the membranes, five (8.3%) operations with the SAS method, and three operations (5%) with the IMA method. Use of nitrocellulose membranes placed near a wound is a valid method for measuring the microbial contamination of air. This method was more sensitive than the IMA method and was not subject to any calibration bias, unlike active air monitoring systems. Copyright © 2011 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  15. Ambient krypton-85 air sampling at Hanford

    International Nuclear Information System (INIS)

    Trevathan, M.S.; Price, K.R.

    1985-01-01

    In the fall of 1982, the Environmental Evaluations Section of Pacific Northwest Laboratory (PNL) initiated a network of continuous 85 Kr air samplers located on and around the Hanford Site. This effort was in response to the resumption of operations at a nuclear fuel reprocessing plant located onsite where 85 Kr was to be released during fuel dissolution. Preoperational data were collected using noble gas samplers designed by the Environmental Protection Agency-Las Vegas (EPA-LV). The samplers functioned erratically resulting in excessive maintenance costs and prompted a search for a new sampling system. State-of-the-art 85 Dr sampling methods were reviewed and found to be too costly, too complex and inappropriate for field application, so a simple bag collection system was designed and field tested. The system is composed of a reinforced, heavy plastic bag, connected to a variable flow pump and housed in a weatherproof enclosure. At the end of the four week sampling period the air in the bag is transferred by a compressor into a pressure tank for easy transport to the laboratory for analysis. After several months of operation, the air sampling system has proven its reliability and sensitivity to ambient levels of 85 Kr

  16. Ambient krypton-85 air sampling at Hanford

    International Nuclear Information System (INIS)

    Trevathan, M.S.; Price, K.R.

    1984-10-01

    In the fall of 1982, the Environmental Evaluations Section of Pacific Northwest Laboratory (PNL) initiated a network of continuous krypton-85 air samplers located on and around the Hanford Site. This effort was in response to the resumption of operations at a nuclear fuel reprocessing plant located onsite where krypton-85 was to be released during fuel dissolution. Preoperational data were collected using noble gas samplers designed by the Environmental Protection Agency-Las Vegas (EPA-LV). The samplers functioned erratically resulting in excessive maintenance costs and prompted a search for a new sampling system. State of the art krypton-85 sampling methods were reviewed and found to be too costly, too complex and inappropriate for field application, so a simple bag collection system was designed and field tested. The system is composed of a reinforced, heavy plastic bag, connected to a variable flow pump and housed in a weatherproof enclosure. At the end of the four week sampling period the air in the bag is transferred by a compressor into a pressure tank for easy transport to the laboratory for analysis. After several months of operation, the air sampling system has proven its reliability and sensitivity to ambient levels of krypton-85. 3 references, 3 figures, 1 table

  17. Effect of operating conditions on performance of silica gel-water air-fluidised desiccant cooler

    Directory of Open Access Journals (Sweden)

    Rogala Zbigniew

    2017-01-01

    Full Text Available Fluidised desiccant cooling is reported in the literature as an efficient way to provide cooling for air-conditioning purposes. The performance of this technology can be described by electric and thermal Coefficients of Performance (COP and Specific Cooling Power (SCP. In this paper comprehensive theoretical study was carried out in order to assess the effect of operating conditions such as: superficial air velocity, desiccant particle diameter, bed switching time and desiccant filling height on the performance of fluidised desiccant cooler (FDC. It was concluded that FDC should be filled with as small as possible desiccant particles featuring diameters and should not be operated with shorter switching times than optimum. Moreover in order to efficiently run such systems superficial air velocities during adsorption and desorption should be similar. At last substantial effect of desiccant filling height on performance of FDC was presented.

  18. Impact of operating wood-burning fireplace ovens on indoor air quality.

    Science.gov (United States)

    Salthammer, Tunga; Schripp, Tobias; Wientzek, Sebastian; Wensing, Michael

    2014-05-01

    The use of combustion heat sources like wood-burning fireplaces has regained popularity in the past years due to increasing energy costs. While the outdoor emissions from wood ovens are strictly regulated in Germany, the indoor release of combustion products is rarely considered. Seven wood burning fireplaces were tested in private homes between November 2012 and March 2013. The indoor air quality was monitored before, during and after operation. The following parameters were measured: ultra-fine particles (5.6-560 nm), fine particles (0.3-20 μm), PM2.5, NOx, CO, CO2, formaldehyde, acetaldehyde, volatile organic compounds (VOCs) and benzo[a]pyrene (BaP). Most ovens were significant sources of particulate matter. In some cases, an increase of benzene and BaP concentrations was observed in the indoor air. The results illustrate that wood-burning fireplaces are potential sources of indoor air contaminants, especially ultra-fine particles. Under the aspect of lowering indoor air exchange rates and increasing the use of fuels with a net zero-carbon footprint, indoor combustion sources are an important topic for the future. With regards to consumer safety, product development and inspection should consider indoor air quality in addition to the present fire protection requirements. Copyright © 2013 Elsevier Ltd. All rights reserved.

  19. Limiting excessive postoperative blood transfusion after cardiac procedures. A review.

    OpenAIRE

    Ferraris, V A; Ferraris, S P

    1995-01-01

    Analysis of blood product use after cardiac operations reveals that a few patients ( 80%). The risk factors that predispose a minority of patients to excessive blood use include patient-related factors, transfusion practices, drug-related causes, and procedure-related factors. Multivariate studies suggest that patient age and red blood cell volume are independent patient-related variables that predict excessive blood product transfusion aft...

  20. 77 FR 12373 - Pilot Certification and Qualification Requirements for Air Carrier Operations

    Science.gov (United States)

    2012-02-29

    ... techniques, high speed and high altitude programming of automatic flight control systems, transport aircraft... in an air multiengine time). carrier operational environment. (216). Aircraft type rating for the... rating exposes the pilot to an advanced multiengine aircraft and a multicrew environment. The FAA...

  1. A Multiple Agent Model of Human Performance in Automated Air Traffic Control and Flight Management Operations

    Science.gov (United States)

    Corker, Kevin; Pisanich, Gregory; Condon, Gregory W. (Technical Monitor)

    1995-01-01

    A predictive model of human operator performance (flight crew and air traffic control (ATC)) has been developed and applied in order to evaluate the impact of automation developments in flight management and air traffic control. The model is used to predict the performance of a two person flight crew and the ATC operators generating and responding to clearances aided by the Center TRACON Automation System (CTAS). The purpose of the modeling is to support evaluation and design of automated aids for flight management and airspace management and to predict required changes in procedure both air and ground in response to advancing automation in both domains. Additional information is contained in the original extended abstract.

  2. Final Approval of California Air Plan Revision; Antelope Valley Air Quality Management District; VOCs From Motor Vehicle Assembly Coating Operations

    Science.gov (United States)

    EPA is taking final action to approve a revision to the Antelope Valley Air Quality Management District (AVAQMD) portion of the California SIP concerning the emissions of volatile organic compounds (VOCs) from motor vehicle assembly coating operations.

  3. Airborne Observations of Water Vapor Deuterium Excess in the Mid-Latitude Lower Troposphere

    Science.gov (United States)

    Salmon, O. E.; Welp, L.; Shepson, P. B.; Stirm, B. H.

    2017-12-01

    Water vapor is responsible for over half of the natural atmospheric greenhouse effect. As global temperatures increase due to fossil fuel combustion, atmospheric water vapor concentrations are also expected to increase in positive feedback. Additionally, studies have shown that urban areas can influence humidity levels, and the frequency and intensity of precipitation events. It is thus important to understand anthropogenic modification of the hydrological cycle, particularly around urban areas, where over half of the world's population resides. Airborne measurements of water vapor isotopologues containing 2H and 18O were conducted to better understand processes influencing atmospheric moisture levels around urban areas. Airborne measurements were conducted around the Indianapolis and Washington, D.C.-Baltimore areas during afternoon hours in February and March 2016, using a Los Gatos Research Water Vapor Isotope Analyzer installed in Purdue University's experimental aircraft, the Airborne Laboratory for Atmospheric Research. The measurements of 2H and 18O allow for the calculation of deuterium excess (= δ2H - 8*δ18O), which provides information about non-equilibrium processes, such as kinetic effects, air parcel mixing, and transpiration. There are few studies that have reported observations of deuterium excess above the surface level ( 100 m). During the measurement campaign, vertical profiles were frequently conducted from 300 m above the ground to an altitude of approximately 1.5 km, effectively characterizing water vapor isotope profiles spanning the boundary layer and lower free troposphere. Measurements probed the transition from planetary boundary layer air to free troposphere air to provide high resolution deuterium excess information across this interface. Processes such as Rayleigh distillation, atmospheric mixing, and surface fluxes potentially impacting water vapor deuterium excess through the boundary layer and free troposphere with be discussed.

  4. Gases emissions and excess air measurements for performance analysis of a wood stove

    Energy Technology Data Exchange (ETDEWEB)

    Carmo, Felipe Alfaia do; Canto, Sergio Aruana Elarrat; Nogueira, Manoel Fernandes Martins; Maneschy, Carlos Edilson de Almeida; Santos, Tiago da Silva; Gazel, Hussein Felix [Universidade Federal do Para (UFPA), Belem, PA (Brazil). Campus Universitario Jose da Silveira Netto], E-mails: aruana@ufpa.br, mfmn@ufpa.br, cemaneschy@ufpa.br

    2010-07-01

    Millions of people in Africa, Central and South America and Asia rely on rudimentary and inefficient wood stove that causes respiratory diseases and demand for large quantity of biomass from native forest. The international agents as World Bank, UNESCO and International Energy Agency has pointed out the relevancy of wood stove. Research on this subject has been done by Shell Foundation and Aprovecho Research Center that indicates Rocket Stove technology as the most promising and able to provide efficiency together with low cost. This work presents performance results obtained from one wood rocket stove manufactured by a Brazilian company named Ecofogao. The stove performance was measured characterizing the amount of energy supplied to the stove in the biomass and characterizing the eluding gases. The incoming energy was quantified through the high heating value for the Jabot (using a bomb calorimeter) plus the Ultimate Analysis (content of carbon, hydrogen, nitrogen and oxygen), Proximate Analysis (content of moisture, fixed carbon, volatiles and ash) and the mass flow rate of biomass feed to the stoven. The leaving energy in the exhaustion gases was quantified measuring its temperature and composition immediately at the exit of the stoven what is the inlet of chimney. The results show the presence of CO{sub 2}, O{sub 2} and CO in the concentration ranges of (0.9% to 6.30%), (14.30% to 19.90%) and (0.17% to 2.50%) respectively. The excess air is in the range (3.33 to 23.33) based on carbon dioxide measurements in the eluted gases. These results provided information to promote also further improvements on the stoven design. (author)

  5. Performance of PEM Liquid-Feed Direct Methanol-Air Fuel Cells

    Science.gov (United States)

    Narayanan, S. R.

    1995-01-01

    A direct methanol-air fuel cell operating at near atmospheric pressure, low-flow rate air, and at temperatures close to 60oC would tremendously enlarge the scope of potential applications. While earlier studies have reported performance with oxygen, the present study focuses on characterizing the performance of a PEM liquid feed direct methanol-air cell consisting of components developed in house. These cells employ Pt-Ru catalyst in the anode, Pt at the cathode and Nafion 117 as the PEM. The effect of pressure, flow rate of air and temperature on cell performance has been studied. With air, the performance level is as high as 0.437 V at 300 mA/cm2 (90oC, 20 psig, and excess air flow) has been attained. Even more significant is the performance level at 60oC, 1 atm and low flow rates of air (3-5 times stoichiometric), which is 0.4 V at 150 mA/cm2. Individual electrode potentials for the methanol and air electrode have been separated and analyzed. Fuel crossover rates and the impact of fuel crossover on the performance of the air electrode have also been measured. The study identifies issues specific to the methanol-air fuel cell and provides a basis for improvement strategies.

  6. Environmental Assessment for Proposed Security Forces Operations Facility, Buckley Air Force Base, Colorado

    National Research Council Canada - National Science Library

    Meyer, Elizabeth; Myklebust, Jessica; Denier, James; Christner, Jennifer; Fontaine, Kathyrn

    2006-01-01

    The United States Air Force (USAF) has prepared this EA in accordance with the National Environmental Policy Act to evaluate the potential environmental and social impacts from the construction and operation of the proposed SFOF...

  7. Analysis of a tool ergonomic working in air traffic control: perceptions of operators and contributions to workload

    Directory of Open Access Journals (Sweden)

    Arlete Ana Motter

    2012-11-01

    Full Text Available The aim of this study was to evaluate the perception of the operators and the role of the strips in the workload of air traffic controllers in light of the ergonomic analysis of work. It was developed during the data collection for the doctoral thesis defended in 2007 at the Post-graduate in Production Engineering at UFSC. Submitted to and approved by the Ethics Committee  in Research of the  Tuiuti University of Paraná. A number of 35 military operators of both sexes (80% male and 20% female participated, all belonging to the Brazilian Air Force, which carried out their functions in the Second Integrated Center of Air Defense and Air Traffic Control (CINDACTA II, located in Curitiba-PR. It was used the methodology of analysis of work ergonomics. The results made it possible to know the content of the prescribed electronic strip and the complexity of work in real activity, such as the manual entry of the strip and the AFIL flight plan. It was verified that the operators build operational strategies in terms of organization of the strips in order to facilitate their work. The conclusion is that in the work of air traffic controller there are several interacting variables, and when the content of the work required is different from what is established, the workload increases, which may endanger the health of workers as well as aircraft safety.

  8. A dynamic model for air-based photovoltaic thermal systems working under real operating conditions

    International Nuclear Information System (INIS)

    Sohel, M. Imroz; Ma, Zhenjun; Cooper, Paul; Adams, Jamie; Scott, Robert

    2014-01-01

    Highlights: • A dynamic model suitable for air-based photovoltaic thermal (PVT) systems is presented. • The model is validated with PVT data from two unique buildings. • The simulated output variables match very well with the experimental data. • The performance of the PVT system under changing working condition is analysed. - Abstract: In this paper a dynamic model suitable for simulating real operating conditions of air-based photovoltaic thermal (PVT) systems is presented. The performance of the model is validated by using the operational data collected from the building integrated photovoltaic (PVT) systems installed in two unique buildings. The modelled air outlet temperature and electrical power match very well with the experimental data. In Solar Decathlon house PVT, the average (RMS) error in air outlet temperatures was 4.2%. The average (RMS) error in electrical power was also 4.2%. In the Sustainable Buildings Research Centre PVT, the average errors (RMS) of PV and air temperatures were 3.8% and 2.2%, respectively. The performance of the PVT system under changing working condition is also analysed in this paper. The analysis includes the effect of ambient air temperature, air inlet temperature, air flow rate and solar irradiation on thermal, electrical, first law and second law efficiencies. Both the thermal and the 1st law efficiencies almost linearly increased with the increase of the ambient temperature. However, the PVT electrical efficiency and the second law efficiency decreased with the increase of the ambient temperature. All efficiencies expect the second law efficiency decreased with increase of the PVT air inlet temperature. The second law efficiency first increased and then reduced. With increasing the air flow rate all the efficiencies increased. The electrical and second law efficiencies become less sensitive when the air flow rate exceeded 300 l/s. Both the thermal and the 1st law efficiencies decreased while the electrical

  9. Operational experience with Seibersdorf low-level incinerator

    International Nuclear Information System (INIS)

    Chalupa, G.

    1987-01-01

    This report contains information about an excess air incinerator which burned low level β and γ wastes (also α up to determined limits). The incinerator was started up in 1980 and it is clear that in a technical plant of such magnitude, some changes and alterations will be needed to be overcome according to the experiences of operation. This paper - after a short description of the incinerator plant itself - gives a summary of some of the operation and the changes which are made in the plant according to these facts. A partial redesign of the incinerator plant in the first half of 1985 resulted in a very satisfying new design, which proved its superiority during the runs in 1985 and 1986

  10. The Effects of Projected Future Demand Including Very Light Jet Air-Taxi Operations on U.S. National Airspace System Delays as a Function of Next Generation Air Transportation System Airspace Capacity

    Science.gov (United States)

    Smith, Jerry; Viken, Jeff; Dollyhigh, Samuel; Trani, Antonio; Baik, Hojong; Hinze, Nicholas; Ashiabor, Senanu

    2007-01-01

    This paper presents the results from a study which investigates the potential effects of the growth in air traffic demand including projected Very Light Jet (VLJ) air-taxi operations adding to delays experienced by commercial passenger air transportation in the year 2025. The geographic region studied is the contiguous United States (U.S.) of America, although international air traffic to and from the U.S. is included. The main focus of this paper is to determine how much air traffic growth, including VLJ air-taxi operations will add to enroute airspace congestion and determine what additional airspace capacity will be needed to accommodate the expected demand. Terminal airspace is not modeled and increased airport capacity is assumed.

  11. Advanced air staging techniques to improve fuel flexibility, reliability and emissions in fluidized bed co-combustion

    Energy Technology Data Exchange (ETDEWEB)

    Aamand, Lars-Erik; Leckner, Bo [Chalmers Technical Univ., Goeteborg (Sweden); Luecke, Karsten; Werther, Joachim [Technical Univ. of Hamburg-Harburg (Germany)

    2001-12-01

    A joint research project between the Technical University of Hamburg-Harburg and Chalmers Technical University. For operation under co-combustion the following results should be considered: The high ash content of the sewage sludge results in significantly increased ash flows. Although high alkali metal concentrations are found in the sewage sludge ash, no critical concentrations were reached and tendencies to fouling were not observed. The trace metal input rises with increased sludge fraction. However, emissions of metal compounds were well below legal limits. The trace metals tend to accumulate on the fly ash. In general, very low fuel nitrogen conversions to NO and N{sub 2}O of 2 - 4 % are achievable. With coal as a base fuel alternative air staging with secondary air supply after solids separation attains even lower NO emissions than normal staging without strongly affecting CO and SO{sub 2} emissions. Alternative staging also reduces N{sub 2}O emissions. An optimum for the excess air ratio in the riser of 1.05 was found for a total excess air ratio of 1.2. The higher the volatile content of the fuel is, the less effective the NO reduction due to air staging becomes. The measurements suggest that the optimum gas residence time regarding the emissions in CFB combustors is around 6 to 7 s. These times are achieved in commercial scale plants due to their large cyclones that perhaps partly can replace a large afterburner chamber. The circulating fluidized bed boiler can be operated in a very flexible way with various fuel mixtures up to an energy fraction of sludge of 25% without exceeding legal emission limits.

  12. Traffic flow and microbial air contamination in operating rooms at a major teaching hospital in Ghana

    DEFF Research Database (Denmark)

    Stauning, M. T.; Bediako-Bowan, A.; Andersen, L. P.

    2018-01-01

    . Aim: To assess microbial air contamination in operating rooms at a Ghanaian teaching hospital and the association with door-openings and number of people present. Moreover, we aimed to document reasons for door-opening. Methods: We conducted active air-sampling using an MAS 100® portable impactor...

  13. The Air Force Air Program and Information Management System (APIMS): A flexible tool for managing your Title V Operating Permits

    Energy Technology Data Exchange (ETDEWEB)

    Weston, A.A.; Gordon, S.R.

    1999-07-01

    The Air Force Command Core System (CCS) is an integrated, activity-based risk management system designed to support the information needs of Environment, Safety, and Occupational Health (ESOH) professionals. These professionals are responsible for managing a complex and often dynamic set of requirements, and therefore, have a need for an information system that can readily be customized to meet their specific needs. This dynamic environment also drives the need for flexibility in the system. The Air Program Information Management System (APIMS) is a module within CCS designed to not only manage permit compliance and emission inventories, but also support the monitoring, recordkeeping, and reporting requirements related to air quality issues. This paper will describe the underlying foundation of CCS, the information linkages within the database, and then summarize the functionality available within the APIMS module to support the Air Quality Managers' information needs, placing emphasis on the flexibility the system provides to manage Title V Operating Permits.

  14. Second Line of Defense, Port of Buenos Aires and Exolgan Container Terminal Operational Testing and Evaluation Plan, Buenos Aires, Argentina

    Energy Technology Data Exchange (ETDEWEB)

    Roberts, Bryan W.

    2012-08-23

    The Office of the Second Line of Defense (SLD) Megaports project team for Argentina will conduct operational testing and evaluation (OT&E) at Exolgan Container Terminal at the Port of Dock Sud from July 16-20, 2012; and at the Port of Buenos Aires from September 3-7, 2012. SLD is installing radiation detection equipment to screen export, import, and transshipment containers at these locations. The purpose of OT&E is to validate and baseline an operable system that meets the SLD mission and to ensure the system continues to perform as expected in an operational environment with Argentina Customs effectively adjudicating alarms.

  15. Intra-operative warming with a forced-air warmer in preventing hypothermia after tourniquet deflation in elderly patients.

    Science.gov (United States)

    Kim, Y-S; Jeon, Y-S; Lee, J-A; Park, W-K; Koh, H-S; Joo, J-D; In, J-H; Seo, K-W

    2009-01-01

    This randomized, single-blind study aimed to explore the effects of intra-operative warming with a forced-air warmer in the prevention of hypothermia after tourniquet deflation in elderly patients undergoing unilateral total knee replacement arthroplasty under general anaesthesia. Patients were randomized to receive either intra-operative warming using a forced-air warmer with an upper body blanket (warming group; n = 12) or no intra-operative warming (nonwarming group; n = 12). Oesophageal temperature was measured as core body temperature. At 30 min following tourniquet inflation, the core body temperature started to increase in the warming group whereas it continued to drop in the non-warming group. This difference was statistically significant. The final core body temperature after tourniquet deflation was significantly higher in the warming group (mean +/- SD 36.1 +/- 0.2 degrees C) than in the non-warming group (35.4 +/- 0.3 degrees C). Intra-operative forced-air warming increased the core body temperature before tourniquet deflation and prevented subsequent hypothermia in elderly patients under general anaesthesia.

  16. Operable Unit 1 remedial investigation report, Eielson Air Force Base, Alaska

    International Nuclear Information System (INIS)

    Gilmore, T.J.; Fruland, R.M.; Liikala, T.L.

    1994-06-01

    This remedial investigation report for operable Unit 1 (OU-1) at Eielson Air Force Base presents data, calculations, and conclusions as to the nature and extent of surface and subsurface contamination at the eight source areas that make up OU-1. The information is based on the 1993 field investigation result and previous investigations. This report is the first in a set of three for OU-1. The other reports are the baseline risk assessment and feasibility study. The information in these reports will lead to a Record of Decision that will guide and conclude the environmental restoration effort for OU-1 at Eielson Air Force Base. The primary contaminants of concern include fuels and fuel-related contaminants (diesel; benzene, toluene, ethylbenzene, and xylene; total petroleum hydrocarbon; polycyclic aromatic hydrocarbons), maintenance-related solvents and cleaners (volatile chlorinated hydrocarbons such as trichloroothylene), polychlorinated biphenyls, and dichlorodiphenyltrichloroethane (DDT). The origins of contaminants of concern include leaks from storage tanks, drums and piping, and spills. Ongoing operations and past sitewide practices also contribute to contaminants of concern at OU-1 source areas. These include spraying mixed oil and solvent wastes on unpaved roads and aerial spraying of DDT

  17. Energy efficiency of freezing tunnels: towards an optimal operation of compressors and air fans

    Energy Technology Data Exchange (ETDEWEB)

    Widell, Kristina Norne

    2012-07-01

    Fish is one of Norway's main exports, and can be shipped fresh, frozen or dried. This thesis examines the freezing of fish in batch tunnels and ways to increase the energy efficiency of this process. A fish freezing plant on the west coast of Norway was used as a baseline case and measurements were made of the freezing system. Different aspects of this system were simulated, mainly using MATLAB.The focus was on the compressors and the freezing tunnels of an industrial refrigeration system. The compressors and the freezing tunnel fans are the largest consumers of electricity, but they are often not operated at the highest efficiency. An analysis of the compressor operation showed that it was far from optimal, with several compressors often operating at part-load simultaneously. These were screw compressors regulated by slide valves, which provide easy capacity control, but also have low energy efficiency. The refrigeration system had several different sized compressors, and the results showed that it was possible to run the system with only one compressor at part-load operation. The total coefficient of performance was improved by as much as 29% for a low production period. A further analysis showed that installing a variable speed drive on one compressor would also improve energy efficiency and make capacity regulation straightforward.The freezing system included five batch freezing tunnels, each of which had a freezing capacity of more than 100 tonnes of pelagic fish. A typical freezing period lasted typically 20 h and decreased the fish temperature to -18?C or below. The main task was to develop a computer program that could simulate the freezing process and the refrigeration system and locate opportunities for improvement. The air velocities inside the freezing tunnel varied with location, which were pinpointed using the computational fluid dynamics software program Airpak. These velocities were used in freezing time calculations. It was shown that a guide

  18. Redox Toxicology of Ambient Air Pollution

    Science.gov (United States)

    Ambient air pollution is a leading global cause of morbidity and mortality. Millions of Americans live in areas in which levels of tropospheric ozone exceed air quality standards, while exposure to particulate matter (PM2.5) alone results in 3.2 million excess deaths annually wor...

  19. Evaluation of thermal overload in boiler operators.

    Science.gov (United States)

    Braga, Camila Soares; Rodrigues, Valéria Antônia Justino; Campos, Julio César Costa; de Souza, Amaury Paulo; Minette, Luciano José; de Moraes, Angêlo Casali; Sensato, Guilherme Luciano

    2012-01-01

    The Brazilians educational institutions need a large energy demand for the operation of laundries, restaurants and accommodation of students. Much of that energy comes from steam generated in boilers with wood fuel. The laboral activity in boiler may present problems for the operator's health due to exposure to excessive heat, and its operation has a high degree of risk. This paper describes an analysis made the conditions of thermal environment in the operation of a B category boiler, located at a Higher Education Institution, located in the Zona da Mata Mineira The equipments used to collect data were Meter WBGT of the Heat Index; Meter of Wet Bulb Index and Globe Thermometer (WBGT); Politeste Instruments, an anemometer and an Infrared Thermometer. By the application of questionnaires, the second phase consisted of collecting data on environmental factors (temperature natural environment, globe temperature, relative humidity and air velocity). The study concluded that during the period evaluated, the activity had thermal overload.

  20. Impacts and mitigation of excess diesel-related NOx emissions in 11 major vehicle markets

    Science.gov (United States)

    Anenberg, Susan C.; Miller, Joshua; Minjares, Ray; Du, Li; Henze, Daven K.; Lacey, Forrest; Malley, Christopher S.; Emberson, Lisa; Franco, Vicente; Klimont, Zbigniew; Heyes, Chris

    2017-05-01

    Vehicle emissions contribute to fine particulate matter (PM2.5) and tropospheric ozone air pollution, affecting human health, crop yields and climate worldwide. On-road diesel vehicles produce approximately 20 per cent of global anthropogenic emissions of nitrogen oxides (NOx), which are key PM2.5 and ozone precursors. Regulated NOx emission limits in leading markets have been progressively tightened, but current diesel vehicles emit far more NOx under real-world operating conditions than during laboratory certification testing. Here we show that across 11 markets, representing approximately 80 per cent of global diesel vehicle sales, nearly one-third of on-road heavy-duty diesel vehicle emissions and over half of on-road light-duty diesel vehicle emissions are in excess of certification limits. These excess emissions (totalling 4.6 million tons) are associated with about 38,000 PM2.5- and ozone-related premature deaths globally in 2015, including about 10 per cent of all ozone-related premature deaths in the 28 European Union member states. Heavy-duty vehicles are the dominant contributor to excess diesel NOx emissions and associated health impacts in almost all regions. Adopting and enforcing next-generation standards (more stringent than Euro 6/VI) could nearly eliminate real-world diesel-related NOx emissions in these markets, avoiding approximately 174,000 global PM2.5- and ozone-related premature deaths in 2040. Most of these benefits can be achieved by implementing Euro VI standards where they have not yet been adopted for heavy-duty vehicles.

  1. Impacts and mitigation of excess diesel-related NOx emissions in 11 major vehicle markets.

    Science.gov (United States)

    Anenberg, Susan C; Miller, Joshua; Minjares, Ray; Du, Li; Henze, Daven K; Lacey, Forrest; Malley, Christopher S; Emberson, Lisa; Franco, Vicente; Klimont, Zbigniew; Heyes, Chris

    2017-05-25

    Vehicle emissions contribute to fine particulate matter (PM 2.5 ) and tropospheric ozone air pollution, affecting human health, crop yields and climate worldwide. On-road diesel vehicles produce approximately 20 per cent of global anthropogenic emissions of nitrogen oxides (NO x ), which are key PM 2.5 and ozone precursors. Regulated NO x emission limits in leading markets have been progressively tightened, but current diesel vehicles emit far more NO x under real-world operating conditions than during laboratory certification testing. Here we show that across 11 markets, representing approximately 80 per cent of global diesel vehicle sales, nearly one-third of on-road heavy-duty diesel vehicle emissions and over half of on-road light-duty diesel vehicle emissions are in excess of certification limits. These excess emissions (totalling 4.6 million tons) are associated with about 38,000 PM 2.5 - and ozone-related premature deaths globally in 2015, including about 10 per cent of all ozone-related premature deaths in the 28 European Union member states. Heavy-duty vehicles are the dominant contributor to excess diesel NO x emissions and associated health impacts in almost all regions. Adopting and enforcing next-generation standards (more stringent than Euro 6/VI) could nearly eliminate real-world diesel-related NO x emissions in these markets, avoiding approximately 174,000 global PM 2.5 - and ozone-related premature deaths in 2040. Most of these benefits can be achieved by implementing Euro VI standards where they have not yet been adopted for heavy-duty vehicles.

  2. Improvement of the vibration of the test fuel(Type-B) with a guide tube under operational condition

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Dong Seung; Yim, Jeong Sik; Lim, I. C. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-04-01

    The Type-B test fuel for the Hanaro has a flexible guide tube on top of the fuel to lead and guide the instrumentation wires. Depending on the flow condition in the reactor, the fuel is susceptible to vibration. During the test operation of the fuel, a fairly large amplitude vibration was observed and the possibility of flow tube contact with adjacent flow tubes, due to the excessive vibration of the fuel, and consequent wear or defect of the flow tubes were raised. Thus, to know the vibration characteristics as well as whether the flow tube contact each other, analyses of the Type-B fuel the dummy fuel were performed by BEVIRA and ANSYS. Besides the analyses, vibration tests using the dummy fuel in air and with Type-B fuel in the core at zero power under operational flow condition were executed. The results from the analyses were compared with those from tests to validate the analyses. From the deflection test of the dummy fuel in air to get the maximum displacement of the flow tube at the top, the flow tube were found to contact each other. For the prevention of the contact of the flow tubes caused by the excessive vibration of the guide tube, an additional support to the guide tube was proposed. With the additional support, analysis and in core vibration test under operational flow condition were conducted and there found to be no excessive vibration any more. 6 refs., 16 figs., 6 tabs. (Author)

  3. Variation in excess oxidant factor in combustion products of MHD generator. [Natural gas fuel

    Energy Technology Data Exchange (ETDEWEB)

    Pinkhasik, M S; Mironov, V D; Zakharko, Yu A; Plavinskii, A I

    1977-12-01

    Methods and difficulties associated with determining the excess oxidant factor for natural gas-fired MHD generators are discussed. The measurement of this factor is noted to be essential for the optimization of the combustion chamber and operation of MHD generators. A gas analyzer of electrochemical type is considered as a quick - response sensor capable of analyzing the composition of the combustion products and thus determining accurately the excess oxidant factor. The principle of operation of this sensor is discussed and the dependence of the electrochemical sensor emf on excess oxidant factor is shown. Three types of sensors are illustrated and tables of test results are provided.

  4. California; Antelope Valley Air Quality Management District; VOCs from Motor Vehicle Assembly Coating Operations

    Science.gov (United States)

    EPA is proposing to approve a revision to the Antelope Valley Air Quality Management District portion of the California SIP concerning emissions of volatile organic compounds (VOCs) from motor vehicle assembly coating operations.

  5. Forced-air warming: a source of airborne contamination in the operating room?

    Science.gov (United States)

    Albrecht, Mark; Gauthier, Robert; Leaper, David

    2009-10-10

    Forced-air-warming (FAW) is an effective and widely used means for maintaining surgical normothermia, but FAW also has the potential to generate and mobilize airborne contamination in the operating room.We measured the emission of viable and non-viable forms of airborne contamination from an arbitrary selection of FAW blowers (n=25) in the operating room. A laser particle counter measured particulate concentrations of the air near the intake filter and in the distal hose airstream. Filtration efficiency was calculated as the reduction in particulate concentration in the distal hose airstream relative to that of the intake. Microbial colonization of the FAW blower's internal hose surfaces was assessed by culturing the microorganisms recovered through swabbing (n=17) and rinsing (n=9) techniques.Particle counting revealed that 24% of FAW blowers were emitting significant levels of internally generated airborne contamination in the 0.5 to 5.0 µm size range, evidenced by a steep decrease in FAW blower filtration efficiency for particles 0.5 to 5.0 µm in size. The particle size-range-specific reduction in efficiency could not be explained by the filtration properties of the intake filter. Instead, the reduction was found to be caused by size-range-specific particle generation within the FAW blowers. Microorganisms were detected on the internal air path surfaces of 94% of FAW blowers.The design of FAW blowers was found to be questionable for preventing the build-up of internal contamination and the emission of airborne contamination into the operating room. Although we did not evaluate the link between FAW and surgical site infection rates, a significant percentage of FAW blowers with positive microbial cultures were emitting internally generated airborne contamination within the size range of free floating bacteria and fungi (<4 µm) that could, conceivably, settle onto the surgical site.

  6. Complexity analysis of the Next Gen Air Traffic Management System: trajectory based operations.

    Science.gov (United States)

    Lyons, Rhonda

    2012-01-01

    According to Federal Aviation Administration traffic predictions currently our Air Traffic Management (ATM) system is operating at 150 percent capacity; forecasting that within the next two decades, the traffic with increase to a staggering 250 percent [17]. This will require a major redesign of our system. Today's ATM system is complex. It is designed to safely, economically, and efficiently provide air traffic services through the cost-effective provision of facilities and seamless services in collaboration with multiple agents however, contrary the vision, the system is loosely integrated and is suffering tremendously from antiquated equipment and saturated airways. The new Next Generation (Next Gen) ATM system is designed to transform the current system into an agile, robust and responsive set of operations that are designed to safely manage the growing needs of the projected increasingly complex, diverse set of air transportation system users and massive projected worldwide traffic rates. This new revolutionary technology-centric system is dynamically complex and is much more sophisticated than it's soon to be predecessor. ATM system failures could yield large scale catastrophic consequences as it is a safety critical system. This work will attempt to describe complexity and the complex nature of the NextGen ATM system and Trajectory Based Operational. Complex human factors interactions within Next Gen will be analyzed using a proposed dual experimental approach designed to identify hazards, gaps and elicit emergent hazards that would not be visible if conducted in isolation. Suggestions will be made along with a proposal for future human factors research in the TBO safety critical Next Gen environment.

  7. Air Force Support of Army Ground Operations Lessons Learned during World War II, Korea, and Vietnam

    Science.gov (United States)

    1989-03-06

    Th ;e 8epre--cdin this paper .rv thoe. of ’:ceauhor IDep 2rtmt-nt of Diefense rayo t gr: s hsPcC % FOC, O P 0- C GOUND OP!-txA’TONS ’A NS tTAI.D 11...NOTE S T edder, Wi.th Preudice: The War Memoirs . - y Air Force. Lord Tedaer. rr- 40-43. 2.".~ : X :"~ , M~.c, ’ = A r Power in Three Wars WW 7:, Kora...that FEAF assume operational control over land based Marine air units and over carri.er bjdsed aviation operating over Korea effective as soon as X

  8. Excessive Daytime Sleepiness

    Directory of Open Access Journals (Sweden)

    Yavuz Selvi

    2016-06-01

    Full Text Available Excessive daytime sleepiness is one of the most common sleep-related patient symptoms, with preva-lence in the community estimated to be as high as 18%. Patients with excessive daytime sleepiness may exhibit life threatening road and work accidents, social maladjustment, decreased academic and occupational performance and have poorer health than comparable adults. Thus, excessive daytime sleepiness is a serious condition that requires investigation, diagnosis and treatment primarily. As with most medical condition, evaluation of excessive daytime sleepiness begins a precise history and various objective and subjective tools have been also developed to assess excessive daytime sleepiness. The most common causes of excessive daytime sleepiness are insufficient sleep hygiene, chronic sleep deprivation, medical and psychiatric conditions and sleep disorders, such as obstructive sleep apnea, medications, and narcolepsy. Treatment option should address underlying contributors and promote sleep quantity by ensuring good sleep hygiene. [Psikiyatride Guncel Yaklasimlar - Current Approaches in Psychiatry 2016; 8(2: 114-132

  9. Operation of a catalytic reverse flow reactor for the purification of air contamined with volatile organic compounds

    NARCIS (Netherlands)

    van de Beld, L.; van de Beld, L.; Westerterp, K.R.

    1997-01-01

    Catalytic oxidation in a reverse flow reactor is an attractive process for the decontamination of air polluted with volatile organic compounds (VOCs). In this paper several aspects of operating this type of reactor for air purification under strongly varying conditions will be discussed. For a

  10. Spatially-varying surface roughness and ground-level air quality in an operational dispersion model

    International Nuclear Information System (INIS)

    Barnes, M.J.; Brade, T.K.; MacKenzie, A.R.; Whyatt, J.D.; Carruthers, D.J.; Stocker, J.; Cai, X.; Hewitt, C.N.

    2014-01-01

    Urban form controls the overall aerodynamic roughness of a city, and hence plays a significant role in how air flow interacts with the urban landscape. This paper reports improved model performance resulting from the introduction of variable surface roughness in the operational air-quality model ADMS-Urban (v3.1). We then assess to what extent pollutant concentrations can be reduced solely through local reductions in roughness. The model results suggest that reducing surface roughness in a city centre can increase ground-level pollutant concentrations, both locally in the area of reduced roughness and downwind of that area. The unexpected simulation of increased ground-level pollutant concentrations implies that this type of modelling should be used with caution for urban planning and design studies looking at ventilation of pollution. We expect the results from this study to be relevant for all atmospheric dispersion models with urban-surface parameterisations based on roughness. -- Highlights: • Spatially variable roughness improved performance of an operational model. • Scenario modelling explored effect of reduced roughness on air pollution. • Reducing surface roughness can increase modelled ground-level pollution. • Damped vertical mixing outweighs increased horizontal advection in model study. • Result should hold for any model with a land-surface coupling based on roughness. -- Spatially varying roughness improves model simulations of urban air pollutant dispersion. Reducing roughness does not always decrease ground-level pollution concentrations

  11. Field Operations and Enforcement Manual for Air Pollution Control. Volume III: Inspection Procedures for Specific Industries.

    Science.gov (United States)

    Weisburd, Melvin I.

    The Field Operations and Enforcement Manual for Air Pollution Control, Volume III, explains in detail the following: inspection procedures for specific sources, kraft pulp mills, animal rendering, steel mill furnaces, coking operations, petroleum refineries, chemical plants, non-ferrous smelting and refining, foundries, cement plants, aluminum…

  12. Design and Operational Evaluation of the Traffic Management Advisor at the Ft. Worth Air Route Traffic Control Center

    Science.gov (United States)

    Swenson, Harry N.; Vincent, Danny; Tobias, Leonard (Technical Monitor)

    1997-01-01

    NASA and the FAA have designed and developed and an automation tool known as the Traffic Management Advisor (TMA). The system was operationally evaluated at the Ft. Worth Air Route Traffic Control Center (ARTCC). The TMA is a time-based strategic planning tool that provides Traffic Management Coordinators and En Route Air Traffic Controllers the ability to efficiently optimize the capacity of a demand impacted airport. The TMA consists of trajectory prediction, constraint-based runway scheduling, traffic flow visualization and controllers advisories. The TMA was used and operationally evaluated for forty-one rush traffic periods during a one month period in the Summer of 1996. The evaluations included all shifts of air traffic operations as well as periods of inclement weather. Performance data was collected for engineering and human factor analysis and compared with similar operations without the TMA. The engineering data indicates that the operations with the TMA show a one to two minute per aircraft delay reduction during rush periods. The human factor data indicate a perceived reduction in en route controller workload as well as an increase in job satisfaction. Upon completion of the evaluation, the TMA has become part of the normal operations at the Ft. Worth ARTCC.

  13. Application of revised procedure on determining large excess reactivity of operating reactor. Fuel addition method

    International Nuclear Information System (INIS)

    Nagao, Yoshiharu

    2002-01-01

    The fuel addition method or the neutron absorption substitution method have been used for determination of large excess multiplication factor of large sized reactors. It has been pointed out, however, that all the experimental methods are possibly not free from the substantially large systematic error up to 20%, when the value of the excess multiplication factor exceeds about 15%Δk. Then, a basic idea of a revised procedure was proposed to cope with the problem, which converts the increase of multiplication factor in an actual core to that in a virtual core by calculation, because its value is in principle defined not for the former but the latter core. This paper proves that the revised procedure is able to be applicable for large sized research and test reactors through the theoretical analyses on the measurements undertaken at the JMTRC and JMTR cores. The values of excess multiplication factor are accurately determined utilizing the whole core calculation by the Monte Carlo code MCNP4A. (author)

  14. Concept for a Satellite-Based Advanced Air Traffic Management System : Volume 4. Operational Description and Qualitative Assessment.

    Science.gov (United States)

    1974-02-01

    The volume presents a description of how the Satellite-Based Advanced Air Traffic Management System (SAATMS) operates and a qualitative assessment of the system. The operational description includes the services, functions, and tasks performed by the...

  15. Comparison of three distinct clean air suits to decrease the bacterial load in the operating room: an observational study.

    Science.gov (United States)

    Kasina, Piotr; Tammelin, Ann; Blomfeldt, Anne-Marie; Ljungqvist, Bengt; Reinmüller, Berit; Ottosson, Carin

    2016-01-01

    Lowering air-borne bacteria counts in the operating room is essential in prevention of surgical site infections in orthopaedic joint replacement surgery. This is mainly achieved by decreasing bacteria counts through dilution, with appropriate ventilation and by limiting the bacteria carrying skin particles, predominantly shed by the personnel. The aim of this study was to investigate if a single use polypropylene clothing system or a reusable polyester clothing system could offer similar air quality in the operating room as a mobile laminar airflow device-assisted reusable cotton/polyester clothing system. Prospective observational study design, comparing the performance of three Clean Air Suits by measuring Colony Forming Units (CFU)/m(3) of air during elective hip and knee arthroplasties, performed at a large university-affiliated hospital. The amount of CFU/m(3) of air was measured during 37 operations of which 13 were performed with staff dressed in scrub suits made of a reusable mixed material (69 % cotton, 30 % polyester, 1 % carbon fibre) accompanied by two mobile laminar airflow units. During 24 procedures no mobile laminar airflow units were used, 13 with staff using a reusable olefin fabric clothing (woven polypropylene) and 11 with staff dressed in single-use suits (non-woven spunbonded polypropylene). Air from the operating field was sampled through a filter, by a Sartorius MD8, and bacterial colonies were counted after incubation. There were 6-8 measurements from each procedure, in total 244 measurements. Statistical analysis was performed by Mann-Whitney U-test. The single-use polypropylene suit reduced the amount of CFU/m(3) to a significantly lower level than both other clothing systems. Single-use polypropylene clothing systems can replace mobile laminar airflow unit-assisted reusable mixed material-clothing systems. Measurements in standardized laboratory settings can only serve as guidelines as environments in real operation settings present a

  16. Disposition of excess weapons plutonium from dismantled weapons

    International Nuclear Information System (INIS)

    Jardine, L.J.

    1997-01-01

    With the end of the Cold War and the implementation of various nuclear arms reduction agreements, US and Russia have been actively dismantling tens of thousands of nuclear weapons. As a result,large quantities of fissile materials, including more than 100 (tonnes?) of weapons-grade Pu, have become excess to both countries' military needs. To meet nonproliferation goals and to ensure the irreversibility of nuclear arms reductions, this excess weapons Pu must be placed in secure storage and then, in timely manner, either used in nuclear reactors as fuel or discarded in geologic repositories as solid waste. This disposition in US and Russia must be accomplished in a safe, secure manner and as quickly as practical. Storage of this Pu is a prerequisite to any disposition process, but the length of storage time is unknown. Whether by use as fuel or discard as solid waste, disposition of that amount of Pu will require decades--and perhaps longer, if disposition operations encounter delays. Neither US nor Russia believes that long-term secure storage is a substitute for timely disposition of excess Pu, but long-term, safe, secure storage is a critical element of all excess Pu disposition activities

  17. Detectors for alpha particles and X-rays operating in ambient air in pulse counting mode and/or with gas amplification

    CERN Document Server

    Charpak, Georges; Breuil, P; Peskov, Vladimir

    2008-01-01

    Ionization chambers working in ambient air in current detection mode are widely used in several applications such as smoke detection, dosimetry, therapeutic beam monitoring and cetera. The aim of this work was to investigate if gaseous detectors can operate in ambient air in pulse counting mode as well as with gas amplification. . To investigate the feasibility of this method two types of open- end gaseous detectors were build and successfully tested. The first one was a single wire or multiwire cylindrical geometry detector operating in pulse mode at a gas gain of 1. The second type alpha detector was an innovative GEM-like detector with resistive electrodes operating in air in avalanche mode at high gas gains (up to 10E4). A detailed comparison between these two detectors is given as well as comparison with the commercially available alpha detectors. The main advantages of gaseous detectors operating in air in a pulse detection mode are their simplicity, low cost and high sensitivity. One of the possible ap...

  18. Excess winter mortality and cold temperatures in a subtropical city, Guangzhou, China.

    Directory of Open Access Journals (Sweden)

    Chun-Quan Ou

    Full Text Available BACKGROUND: A significant increase in mortality was observed during cold winters in many temperate regions. However, there is a lack of evidence from tropical and subtropical regions, and the influence of ambient temperatures on seasonal variation of mortality was not well documented. METHODS: This study included 213,737 registered deaths from January 2003 to December 2011 in Guangzhou, a subtropical city in Southern China. Excess winter mortality was calculated by the excess percentage of monthly mortality in winters over that of non-winter months. A generalized linear model with a quasi-Poisson distribution was applied to analyze the association between monthly mean temperature and mortality, after controlling for other meteorological measures and air pollution. RESULTS: The mortality rate in the winter was 26% higher than the average rate in other seasons. On average, there were 1,848 excess winter deaths annually, with around half (52% from cardiovascular diseases and a quarter (24% from respiratory diseases. Excess winter mortality was higher in the elderly, females and those with low education level than the young, males and those with high education level, respectively. A much larger winter increase was observed in out-of-hospital mortality compared to in-hospital mortality (45% vs. 17%. We found a significant negative correlation of annual excess winter mortality with average winter temperature (rs=-0.738, P=0.037, but not with air pollution levels. A 1 °C decrease in monthly mean temperature was associated with an increase of 1.38% (95% CI:0.34%-2.40% and 0.88% (95% CI:0.11%-1.64% in monthly mortality at lags of 0-1 month, respectively. CONCLUSION: Similar to temperate regions, a subtropical city Guangzhou showed a clear seasonal pattern in mortality, with a sharper spike in winter. Our results highlight the role of cold temperature on the winter mortality even in warm climate. Precautionary measures should be strengthened to mitigate

  19. Influence of French Air Power Strategy in the European Union’s Military Operations in Africa (2003-2009)

    Science.gov (United States)

    2011-06-01

    Patrick Facon, Histoire de l’Armée de l’Air, provides the context of French operations in Africa in the broadest history of the French Air Force. 3 In...during the 2000s, including its 3 Patrick Facon, Histoire de L’armée de L’air (Paris: La...34, 8. 5 Facon, Histoire de L’armée de L’air, 451. 6 Facon, Histoire de L’armée de L’air, 458. The third phase began in 1994 after the Rwanda

  20. Mitigation of tip vortex cavitation by means of air injection on a Kaplan turbine scale model

    International Nuclear Information System (INIS)

    Rivetti, A; Angulo, M; Lucino, C; Liscia, S

    2014-01-01

    Kaplan turbines operating at full-load conditions may undergo excessive vibration, noise and cavitation. In such cases, damage by erosion associated to tip vortex cavitation can be observed at the discharge ring. This phenomenon involves design features such as (1) overhang of guide vanes; (2) blade profile; (3) gap increasing size with blade opening; (4) suction head; (5) operation point; and (6) discharge ring stiffness, among others. Tip vortex cavitation may cause erosion at the discharge ring and draft tube inlet following a wavy pattern, in which the number of vanes can be clearly identified. Injection of pressurized air above the runner blade centerline was tested as a mean to mitigate discharge ring cavitation damage on a scale model. Air entrance was observed by means of a high-speed camera in order to track the air trajectory toward its mergence with the tip vortex cavitation core. Post-processing of acceleration signals shows that the level of vibration and the RSI frequency amplitude decrease proportionally with air flow rate injected. These findings reveal the potential mitigating effect of air injection in preventing cavitation damage and will be useful in further tests to be performed on prototype, aiming at determining the optimum air flow rate, size and distribution of the injectors

  1. Mitigation of tip vortex cavitation by means of air injection on a Kaplan turbine scale model

    Science.gov (United States)

    Rivetti, A.; Angulo, M.; Lucino, C.; Liscia, S.

    2014-03-01

    Kaplan turbines operating at full-load conditions may undergo excessive vibration, noise and cavitation. In such cases, damage by erosion associated to tip vortex cavitation can be observed at the discharge ring. This phenomenon involves design features such as (1) overhang of guide vanes; (2) blade profile; (3) gap increasing size with blade opening; (4) suction head; (5) operation point; and (6) discharge ring stiffness, among others. Tip vortex cavitation may cause erosion at the discharge ring and draft tube inlet following a wavy pattern, in which the number of vanes can be clearly identified. Injection of pressurized air above the runner blade centerline was tested as a mean to mitigate discharge ring cavitation damage on a scale model. Air entrance was observed by means of a high-speed camera in order to track the air trajectory toward its mergence with the tip vortex cavitation core. Post-processing of acceleration signals shows that the level of vibration and the RSI frequency amplitude decrease proportionally with air flow rate injected. These findings reveal the potential mitigating effect of air injection in preventing cavitation damage and will be useful in further tests to be performed on prototype, aiming at determining the optimum air flow rate, size and distribution of the injectors.

  2. The United States Air Force and Humanitarian Airlift Operations 1947-1994

    Science.gov (United States)

    1998-01-01

    Ecuador . Aftershocks in southern Ecuador on December 10 compounded the destruction in cities and villages such as Loja , Cariamango, Celica, and Alamor... Ecuador . Date(s): August 10–19, 1949. Emergency: An earthquake measuring 7.5 on the Richter scale struck central Ecuador . Air Force Organization(s...Operations: A severe earthquake registering 7.5 on the Richter scale struck the high valleys of central Ecuador in the Andes on Thursday, August 4

  3. Design and operation of a thermionic converter in air

    International Nuclear Information System (INIS)

    Horner, M.H.; Begg, L.L.; Smith, J.N. Jr.; Geller, C.B.; Kallnowski, J.E.

    1995-01-01

    An electrically heated thermionic converter has been designed, built and successfully tested in air. Several unique features were incorporated in this converter: an integral cesium reservoir, innovative ceramic-to-metal seals, a heat rejection system coupling the collector to a low temperature heat sink and an innovative cylindrical heater filament. The converter was operated for extended periods of time with the emitter at about 1900 K. the collector at about 700 K, and a power density of over 2 w(e)/sq. cm. Input power transients were run between 50% and 100% thermal power, at up to 1% per second, without instabilities in performance

  4. Detonation cell size measurements and predictions in hydrogen-air-steam mixtures at elevated temperatures

    International Nuclear Information System (INIS)

    Ciccarelli, G.; Ginsberg, T.; Boccio, J.; Economos, C.

    1994-01-01

    The present research reports on the effect of initial mixture temperature on the experimentally measured detonation cell size for hydrogen-air-steam mixtures. Experimental and theoretical research related to combustion phenomena in hydrogen-air-steam mixtures has been ongoing for many years. However, detonation cell size data currently exists or hydrogen-air-steam mixtures up to a temperature of only 400K. Sever accident scenarios have been identified for light water reactors (LWRs) where hydrogen-air mixture temperatures in excess of 400K could be generated within containment. The experiments in this report focus on extending the cell size data base for initial mixture temperatures in excess of 400K. The experiments were carried out in a 10-cm inner-diameter, 6.1-m long heated detonation tube with a maximum operating temperature of 700K and spatial temperature uniformity of ±14K. Detonation cell size measurements provide clear evidence that the effect of hydrogen-air initial gas mixture temperature, in the range 300K--650K, is to decrease cell size and, hence, to increase the sensitivity of the mixture to undergo detonations. The effect of steam content, at any given temperature, is to increase the cell size and, thereby, to decrease the sensitivity of stoichiometric hydrogen-air mixtures. The hydrogen-air detonability limits for the 10-cm inside-diameter test vessel, based upon the onset of single-head spin, decreased from 15 percent by hydrogen at 300K down to about 9 percent hydrogen at 650K. The one-dimensional ZND model does a very good job at predicting the overall trends in the cell size data over the range of hydrogen-air-steam mixture compositions and temperature studied in the experiments

  5. Airport landside operations and air service

    Science.gov (United States)

    Mandle, P. B.; Whitlock, E. M.; Lamagna, F.; Mundy, R. A.; Oberhausen, P. J.

    The following areas are discussed: airport curbside planning and design; analysis of New Orleans airport ground transportation system; time series analysis of intercity air travel volume; economic justification of air service to small communities; and general aviation and the airport and airway system (an analysis of cost allocation and recovery).

  6. Critical Care Air Transport Team severe traumatic brain injury short-term outcomes during flight for Operation Iraqi Freedom/Operation Enduring Freedom.

    Science.gov (United States)

    Boyd, L Renee; Borawski, J; Lairet, J; Limkakeng, A T

    2017-10-01

    Our understanding of the expertise and equipment required to air transport injured soldiers with severe traumatic brain injuries (TBIs) continue to evolve. We conducted a retrospective chart review of characteristics, interventions required and short-term outcomes of patients with severe TBI managed by the US Air Force Critical Care Air Transport Teams (CCATTs) deployed in support of Operation Iraqi Freedom and Operation Enduring Freedom between 1 June 2007 and 31 August 2010. Patients were cared for based on guidelines given by the Brain Trauma Foundation and the Joint Theater Trauma System by non-neurosurgeon physicians with dedicated neurocritical care training. We report basic characteristics, injuries, interventions required and complications during transport. Intracranial haemorrhage was the most common diagnosis in this cohort. Most injuries were weapon related. During this study, there were no reported in-flight deaths. The majority of patients were mechanically ventilated. There were 45 patients who required at least one vasopressor to maintain adequate tissue perfusion, including four patients who required three or more. Some patients required intracranial pressure (ICP) management, treatment of diabetes insipidus and/or seizure prophylaxis medications. Air transport personnel must be prepared to provide standard critical care but also care specific to TBIs, including ICP control and management of diabetes insipidus. Although these patients and their potential complications are traditionally managed by neurosurgeons, those providers without neurosurgical backgrounds can be provided this training to help fill a wartime need. This study provides data for the future development of air transport guidelines for validating and clearing flight surgeons. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  7. Performance and emission characteristics of a turbocharged spark-ignition hydrogen-enriched compressed natural gas engine under wide open throttle operating conditions

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Fanhua; Wang, Mingyue; Jiang, Long; Deng, Jiao; Chen, Renzhe; Naeve, Nashay; Zhao, Shuli [State Key Laboratory of Automotive Safety and Energy, Tsinghua University, Beijing 100084 (China)

    2010-11-15

    This paper investigates the effect of various hydrogen ratios in HCNG (hydrogen-enriched compressed natural gas) fuels on performance and emission characteristics at wide open throttle operating conditions using a turbocharged spark-ignition natural gas engine. The experimental data was taken at hydrogen fractions of 0%, 30% and 55% by volume and was conducted under different excess air ratio ({lambda}) at MBT operating conditions. It is found that under various {lambda}, the addition of hydrogen can significantly reduce CO, CH{sub 4} emissions and the NO{sub x} emission remain at an acceptable level when ignition timing is optimized. Using the same excess air ratio, as more hydrogen is added the power, exhaust temperatures and max cylinder pressure decrease slowly until the mixture's lower heating value remains unchanged with the hydrogen enrichment, then they rise gradually. In addition, the early flame development period and the flame propagation duration are both shorter, and the indicated thermal efficiency and maximum heat release rate both increase with more hydrogen addition. (author)

  8. Pure Air`s Bailly scrubber: A four-year retrospective

    Energy Technology Data Exchange (ETDEWEB)

    Manavi, G.B.; Vymazal, D.C. [Pure Air, Allentown, PA (United States); Sarkus, T.A. [Dept. of Energy, Pittsburgh, PA (United States)

    1997-12-31

    Pure Air`s Advanced Flue Gas Desulfurization (AFGD) Clean Coal Project has completed four highly successful years of operation at NIPSCO`s Bailly Station. As part of their program, Pure Air has concluded a six-part study of system performance. This paper summarizes the results of the demonstration program, including AFGD performance on coals ranging from 2.0--2.4% sulfur. The paper highlights novel aspects of the Bailly facility, including pulverized limestone injection, air rotary sparger for oxidation, wastewater evaporation system and the production of PowerChip{reg_sign} gypsum. Operations and maintenance which have led to the facility`s notable 99.47% availability record are also discussed. A project company, Pure Air on the Lake Limited Partnership, owns the AFGD facility. Pure Air was the turn key contractor and Air Products and Chemicals, Inc. is the operator of the AFGD system.

  9. Constraints of using thermostatic expansion valves to operate air-cooled chillers at lower condensing temperatures

    International Nuclear Information System (INIS)

    Yu, F.W.; Chan, K.T.; Chu, H.Y.

    2006-01-01

    Thermostatic expansion valves (TXVs) have long been used in air-cooled chillers to implement head pressure control under which the condensing temperature is kept high at around 50 o C by staging condenser fans as few as possible. This paper considers how TXVs prevent the chillers from operating with an increased COP at lower condensing temperatures when the chiller load or outdoor temperature drops. An analysis on an existing air-cooled reciprocating chiller showed that the range of differential pressures across TXVs restricts the maximum heat rejection airflow required to increase the chiller COP, though the set point of condensing temperature is reduced to 22 o C from a high level of 45 o C. It is possible to use electronic expansion valves to meet the differential pressure requirements for maximum chiller COP. There is a maximum of 28.7% increase in the chiller COP when the heat rejection airflow is able to be maximized in various operating conditions. The results of this paper emphasize criteria for lowering the condensing temperature to enhance the performance of air-cooled chillers

  10. Characteristics of charcoal fines obtained by rapid pyrolysis process of elephant grass in fluidized bed in different operation conditions; Caracteristicas dos finos de carvao vegetal obtido pelo processo de pirolise rapida de capim elefante em leito fluidizado em diferentes condicoes de operacao

    Energy Technology Data Exchange (ETDEWEB)

    Mesa Perez, Juan Miguel; Cortez, Luis Augusto Barbosa [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil). Fac. de Engenharia Agricola; Gomez, Edgardo Olivares; Rocha, Jose Dilcio [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil). Nucleo Interdisciplinar de Planejamento Energetico

    2004-07-01

    This paper presents a study about the effect of excess air and the inert fixed bed height upon the characteristics of fine charcoal particles and the main reactor parameters. The pyrolysis process is considered as a method to concentrate carbon in fine charcoal particles and a method to reduce oxygen content in the biomass.The study concludes that the operation point which gives the highest percentage if carbon fine charcoal particles and reduces the most the oxygen in biomass corresponds to a fixed bed height of 207 mm and excess air of 8%. (author)

  11. Increased air temperature during simulated autumn conditions does not increase photosynthetic carbon gain but affects the dissipation of excess energy in seedlings of the evergreen conifer Jack pine.

    Science.gov (United States)

    Busch, Florian; Hüner, Norman P A; Ensminger, Ingo

    2007-03-01

    Temperature and daylength act as environmental signals that determine the length of the growing season in boreal evergreen conifers. Climate change might affect the seasonal development of these trees, as they will experience naturally decreasing daylength during autumn, while at the same time warmer air temperature will maintain photosynthesis and respiration. We characterized the down-regulation of photosynthetic gas exchange and the mechanisms involved in the dissipation of energy in Jack pine (Pinus banksiana) in controlled environments during a simulated summer-autumn transition under natural conditions and conditions with altered air temperature and photoperiod. Using a factorial design, we dissected the effects of daylength and temperature. Control plants were grown at either warm summer conditions with 16-h photoperiod and 22 degrees C or conditions representing a cool autumn with 8 h/7 degrees C. To assess the impact of photoperiod and temperature on photosynthesis and energy dissipation, plants were also grown under either cold summer (16-h photoperiod/7 degrees C) or warm autumn conditions (8-h photoperiod/22 degrees C). Photosynthetic gas exchange was affected by both daylength and temperature. Assimilation and respiration rates under warm autumn conditions were only about one-half of the summer values but were similar to values obtained for cold summer and natural autumn treatments. In contrast, photosynthetic efficiency was largely determined by temperature but not by daylength. Plants of different treatments followed different strategies for dissipating excess energy. Whereas in the warm summer treatment safe dissipation of excess energy was facilitated via zeaxanthin, in all other treatments dissipation of excess energy was facilitated predominantly via increased aggregation of the light-harvesting complex of photosystem II. These differences were accompanied by a lower deepoxidation state and larger amounts of beta-carotene in the warm autumn

  12. 76 FR 77996 - Notice of Issuance of Final Air Permits for Eni US Operating Co., Inc. and Port Dolphin Energy, LLC.

    Science.gov (United States)

    2011-12-15

    ... Final Air Permits for Eni US Operating Co., Inc. and Port Dolphin Energy, LLC. AGENCY: Environmental... 27, 2011, the EPA issued a final Outer Continental Shelf (OCS) air permit for Eni US Operating Inc. (Eni). This permit became effective on November 28, 2011. In addition, the EPA issued a final...

  13. Low-head air stripper treats oil tanker ballast water

    International Nuclear Information System (INIS)

    Goldman, M.

    1992-01-01

    Prototype tests conducted during the winter of 1989/90 have successfully demonstrated an economical design for air stripping volatile hydrocarbons from oily tanker ballast water. The prototype air stripper, developed for Alyeska's Ballast Water Treatment (BWT) facility in Valdez, Alaska, ran continuously for three months with an average removal of 88% of the incoming volatile organics. Initially designed to remove oil and grease compounds from tanker ballast water, the BWT system has been upgraded to a three-step process to comply with new, stringent regulations. The BWT biological oxidation process enhances the growth of bacteria present in the incoming ballast water through nutrient addition, aeration, and recirculation within a complete-mixed bioreactor. The average removal of BETX is over 95%, however, occassional upsets required the placement of a polishing air stripper downstream of the aeration tanks. Packed-tower air stripping was investigated but deemed economically unfeasible for a facility that would only occasionally be used. Twelve feet of excess gravity head in the existing BWT hydraulic gradeline were employed to drive the air stripper feed. This limited the stripper packing depth to 8 feet and imposed constraints on the design of the inlet water and air distributors. Water distribution, air flow, temperature effects, and fouling from constituents in the ballast water were investigated. The prototype was operated under water and air flow conditions similar to those specified for the full-scale unit, and at a range of test conditions above and below the normal design conditions

  14. Determination of the design excess reactivity for the TREAT Upgrade reactor

    International Nuclear Information System (INIS)

    Bhattacharyya, S.K.; Hanan, N.A.

    1983-01-01

    The excess reactivity designed to be built into a reactor core is a primary determinant of the fissile loadings of the fuel rods in the core. For the TREAT Upgrade (TU) reactor the considerations that enter into the determination of the excess reactivity are different from those of conventional power reactors. The reactor is designed to operate in an adiabatic transient mode for reactor safety in-pile test programs. The primary constituent of the excess reactivity is the calculated reactivity required to perform the most demanding transient experiments. Because of the unavailability of supporting critical experiments for the core design, the uncertainty terms that add on to this basic constituent are rather large. The burnup effects in TU are negligible and no refueling is planned. In this paper the determination of the design excess reactivity of the TREAT Upgrade reactor is discussed

  15. Machine & electrical double control air dryer for vehicle air braking system

    Science.gov (United States)

    Zhang, Xuan; Yang, Liu; Wang, Xian Yan; Tan, Xiao Yan; Wang, Wei

    2017-09-01

    As is known to all, a vehicle air brake system, in which usually contains moisture. To solve the problem, it is common to use air dryer to dry compressed air effectively and completely remove the moisture and oil of braking system. However, the existing air dryer is not suitable for all commercial vehicles. According to the operational status of the new energy vehicles in the initial operating period, the structure design principle of the machine & electric control air dryer is expounded from the aspects of the structure and operating principle, research & development process.

  16. Traffic flow and microbial air contamination in operating rooms at a major teaching hospital in Ghana.

    Science.gov (United States)

    Stauning, M T; Bediako-Bowan, A; Andersen, L P; Opintan, J A; Labi, A-K; Kurtzhals, J A L; Bjerrum, S

    2018-07-01

    Current literature examining the relationship between door-opening rate, number of people present, and microbial air contamination in the operating room is limited. Studies are especially needed from low- and middle-income countries, where the risk of surgical site infections is high. To assess microbial air contamination in operating rooms at a Ghanaian teaching hospital and the association with door-openings and number of people present. Moreover, we aimed to document reasons for door-opening. We conducted active air-sampling using an MAS 100 ® portable impactor during 124 clean or clean-contaminated elective surgical procedures. The number of people present, door-opening rate and the reasons for each door-opening were recorded by direct observation using pretested structured observation forms. During surgery, the mean number of colony-forming units (cfu) was 328 cfu/m 3 air, and 429 (84%) of 510 samples exceeded a recommended level of 180 cfu/m 3 . Of 6717 door-openings recorded, 77% were considered unnecessary. Levels of cfu/m 3 were strongly correlated with the number of people present (P = 0.001) and with the number of door-openings/h (P = 0.02). In empty operating rooms, the mean cfu count was 39 cfu/m 3 after 1 h of uninterrupted ventilation and 52 (51%) of 102 samples exceeded a recommended level of 35 cfu/m 3 . The study revealed high values of intraoperative airborne cfu exceeding recommended levels. Minimizing the number of door-openings and people present during surgery could be an effective strategy to reduce microbial air contamination in low- and middle-income settings. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  17. Demonstration of AIRS Total Ozone Products to Operations to Enhance User Readiness

    Science.gov (United States)

    Berndt, Emily; Zavodsky, Bradley; Jedlovec, Gary

    2014-01-01

    Cyclogenesis is a key forecast challenge at operational forecasting centers such as WPC and OPC, so these centers have a particular interest in unique products that can identify key storm features. In some cases, explosively developing extratropical cyclones can produce hurricane force, non-convective winds along the East Coast and north Atlantic as well as the Pacific Ocean, with the potential to cause significant damage to life and property. Therefore, anticipating cyclogenesis for these types of storms is crucial for furthering the NOAA goal of a "Weather Ready Nation". Over the last few years, multispectral imagery (i.e. RGB) products have gained popularity among forecasters. The GOES-R satellite champion at WPC/OPC has regularly evaluated the Air Mass RGB products from GOES Sounder, MODIS, and SEVIRI to aid in forecasting cyclogenesis as part of ongoing collaborations with SPoRT within the framework of the GOES-R Proving Ground. WPC/OPC has used these products to identify regions of stratospheric air associated with tropopause folds that can lead to cyclogenesis and hurricane force winds. RGB products combine multiple channels or channel differences into multi-color imagery in which different colors represent a particular cloud or air mass type. Initial interaction and feedback from forecasters evaluating the legacy Air Mass RGBs revealed some uncertainty regarding what physical processes the qualitative RGB products represent and color interpretation. To enhance forecaster confidence and interpretation of the Air Mass RGB, NASA SPoRT has transitioned a total column ozone product from AIRS retrievals to the WPC/OPC. The use of legacy AIRS demonstrates future JPSS capabilities possible with CrIS or OMPS. Since stratospheric air can be identified by anomalous potential vorticity and warm, dry, ozone-rich air, hyperspectral infrared sounder ozone products can be used in conjunction with the Air Mass RGB for identifying the role of stratospheric air in explosive

  18. Management of Excess Material in the Navys Real Time Reutilization Asset Management Facilities Needs Improvement

    Science.gov (United States)

    2017-01-23

    Commands, that originally purchased the material from the command’s operational and maintenance fund. A flowchart of the RRAM material management process...streamlines business operations for financial and supply chain management . 22 SECNAVINST 4440.33A. The Navy retained excess material stored in 10 of...No. DODIG-2017-043 J A N U A R Y 2 3 , 2 0 1 7 Management of Excess Material in the Navy’s Real-Time Reutilization Asset Management Facilities

  19. Influences of air flow on energy consumption as well as cost of investment and operation of airconditioning plants

    Energy Technology Data Exchange (ETDEWEB)

    Radtke, W

    1981-08-01

    Within research project 'RELA', tests have been made to determine the amount of entering air to be guided from bottom to top and from ceiling to ceiling in order to obtain equal cooling capacity and air quality as well as equal entering air temperature. On the basis of these results, the 'Schmidt-Reuter Ingenieurgesellschaft', Cologne/Germany, has investigated the effects of air flow on the energy consumption for the equal air conditioning of a conventional office building. Since the energy consumption is also influenced by the sort of air treatment, energy transport by air or water, the selected air temperatures and the adaption of the plant to part-load, the calculation has been performed for a larger number of air treatment and control systems customary today. Furthermore, the effects of the type of air flow on plant size, plant rooms and building construction are shown. The author reports on the resulting influences of the type of air flow on energy consumption and cost of operation.

  20. Analysis of impacts on urban air quality by restricting the operation of passenger vehicles during Asian Game events in Busan, Korea

    Science.gov (United States)

    Lee, Byeong-Kyu; Jun, Na-Young; Lee, Haengah Kim

    This study is an analysis of the impacts on urban air quality of restricting the operation of passenger vehicles during the 24th Asian Games (AG). Passenger vehicles in Busan were not allowed to operate on the alternative days during the AG period. This restricted operation of passenger vehicles was enforced to improve an urban air quality in Busan during the AG period. The average usage rate of passenger vehicles under an alternate (or restricted) operation was 95.4% and thus the average traffic flow rate (vehicle operation speed) increased approximately 28.1% as compared to normal periods. We analyzed the ambient concentrations of criteria air pollutants measured at 13 air-monitoring stations in Busan (Pusan), Korea, for the three periods of "before (13-28 September 2002)", "during (29 September-14 October 2002)" and "after (15-30 October 2002)" the AG. The 1-h, 24-h and 16-day averages or median concentrations of each classified term were compared to those of other terms. The median concentrations, based on 24-h average data of each day, of PM 10, CO, NO 2, and SO 2 in the ambient during the alternate operation period of 16 days substantially increased as compared to the terms before or after. However, the median concentration of O 3 during the AG period was slightly less than that of the term before. The ambient O 3 concentrations during daytime (12:00-19:00) under alternate operation substantially increased as compared to the terms before or after. However, the ambient O 3 concentrations during nighttime (22:00-07:00) under alternate operation decreased when compared to the terms before or after. For the alternate operation period of passenger vehicles, the average concentrations of PM 10, NO 2, SO 2, and daytime O 3 measured at the air-monitoring stations near the stadiums were much higher than those of the other areas excluding the stadium areas. However, average CO concentrations at the other areas were higher than those nearby the stadiums during the

  1. Excess cardiovascular mortality associated with cold spells in the Czech Republic

    Directory of Open Access Journals (Sweden)

    Kyncl Jan

    2009-01-01

    Full Text Available Abstract Background The association between cardiovascular mortality and winter cold spells was evaluated in the population of the Czech Republic over 21-yr period 1986–2006. No comprehensive study on cold-related mortality in central Europe has been carried out despite the fact that cold air invasions are more frequent and severe in this region than in western and southern Europe. Methods Cold spells were defined as periods of days on which air temperature does not exceed -3.5°C. Days on which mortality was affected by epidemics of influenza/acute respiratory infections were identified and omitted from the analysis. Excess cardiovascular mortality was determined after the long-term changes and the seasonal cycle in mortality had been removed. Excess mortality during and after cold spells was examined in individual age groups and genders. Results Cold spells were associated with positive mean excess cardiovascular mortality in all age groups (25–59, 60–69, 70–79 and 80+ years and in both men and women. The relative mortality effects were most pronounced and most direct in middle-aged men (25–59 years, which contrasts with majority of studies on cold-related mortality in other regions. The estimated excess mortality during the severe cold spells in January 1987 (+274 cardiovascular deaths is comparable to that attributed to the most severe heat wave in this region in 1994. Conclusion The results show that cold stress has a considerable impact on mortality in central Europe, representing a public health threat of an importance similar to heat waves. The elevated mortality risks in men aged 25–59 years may be related to occupational exposure of large numbers of men working outdoors in winter. Early warnings and preventive measures based on weather forecast and targeted on the susceptible parts of the population may help mitigate the effects of cold spells and save lives.

  2. The influence of typical ways of operating and air-handling unit on the sensory pollution load from used bag filters

    DEFF Research Database (Denmark)

    Mysen, M.; Clausen, Geo; Bekö, Gabriel

    2003-01-01

    An experiment was performed to determine whether the sensory pollution emitted from a bag filter that had been used for 3 months in a suburban area in Denmark was influenced by different ways of operating the air-handling unit (AHU). Samples of the used filter were pre-conditioned to simulate thr...... the airflow outside working hours would significantly increase the sensory pollution emitted by a used bag filter immediately after the AHU is turned on, in comparison with continuous airflow through the AHU (P...... operating conditions: 1) switched off overnight; 2) airflow reduced to 10% overnight; and 3) continuous 100% operation. Outside air passed through the samples and the acceptability of the air after the filter was assessed by a panel of subjects. The results indicate that turning off the AHU or reducing...

  3. Field Operations and Enforcement Manual for Air Pollution Control. Volume II: Control Technology and General Source Inspection.

    Science.gov (United States)

    Weisburd, Melvin I.

    The Field Operations and Enforcement Manual for Air Pollution Control, Volume II, explains in detail the following: technology of source control, modification of operations, particulate control equipment, sulfur dioxide removal systems for power plants, and control equipment for gases and vapors; inspection procedures for general sources, fuel…

  4. Control rod excess withdrawal prevention device

    International Nuclear Information System (INIS)

    Takayama, Yoshihito.

    1992-01-01

    Excess withdrawal of a control rod of a BWR type reactor is prevented. That is, the device comprises (1) a speed detector for detecting the driving speed of a control rod, (2) a judging circuit for outputting an abnormal signal if the driving speed is greater than a predetermined level and (3) a direction control valve compulsory closing circuit for controlling the driving direction of inserting and withdrawing a control rod based on an abnormal signal. With such a constitution, when the with drawing speed of a control rod is greater than a predetermined level, it is detected by the speed detector and the judging circuit. Then, all of the direction control valve are closed by way of the direction control valve compulsory closing circuit. As a result, the operation of the control rod is stopped compulsorily and the withdrawing speed of the control rod can be lowered to a speed corresponding to that upon gravitational withdrawal. Accordingly, excess withdrawal can be prevented. (I.S)

  5. AN IMPACT OF THE EFFICIENT FUNCTIONING OF THE VENTILATION AND AIR-CONDITIONING SYSTEM ON THERMAL COMFORT OF THE MEDICAL STAFF IN THE OPERATING ROOM

    Directory of Open Access Journals (Sweden)

    Tomasz Jankowski

    2016-11-01

    Full Text Available Ventilation and air conditioning systems are necessary for developing proper parameters of indoor envi-ronment in operating rooms. The main task of ventilation and air conditioning in those specific areas consists in creating desirable temperature, reducing the number of microorganisms and the concen-trations of hazardous gases and substances in the air, as well as ensuring the proper direction of airflow. In Poland, indoor environment in operating rooms has to comply with the requirements set out in three regulations (Journal of Laws of 2002 No. 75, item 690, as amended, Journal of Laws of 2002 No. 217, item 1833, Journal of Laws of 2011 No. 31, item 158, as amended and the document entitled "Guidelines for the design of general hospitals". Given insufficient accuracy of the abovementioned national documents, it is a common practice to use foreign standards, i.e. ASHRAE Standard 170-2013, DIN 1946-4: 2008 and FprCEN TR 16244: 2011. When considering the conditions for thermal comfort, it is important to bear in mind a close link between air flow velocity and air temperature. Air in the zone occupied by patients and medical staff must not cause the sensation of draft. Furthermore, air velocity should be sufficient to eliminate interference caused by the presence of people and other sources of heat. It should also reduce the turbulence level in the air in the operating room. Efficient functioning of ventilation and air conditioning was tested during treatments and operations carried out on three wards of a Warsaw hospital. Tests were performed with the participation of medical staff from various surgical units. They were asked to perform minor manual tasks to simulate work on the op-erating table, and to complete a questionnaire on subjective thermal sensation. The applied methodology is widely used during testing of general and local ventilation in public buildings. Air temperature, relative humidity, air flow supply and exhaust air from the

  6. Reduction in energy consumption and operating cost in a dried corn warehouse using logistics techniques

    Directory of Open Access Journals (Sweden)

    Korrakot Y. Tippayawong

    2013-06-01

    Full Text Available Corn is one of the major economic crops in Thailand. Corn postharvest operation involves various practices that consume a large amount of energy. Different energy conservation measures have been implemented but logistics consideration is not normally employed. In this work, attempt has been made to demonstrate that logistics techniques can offer a significant reduction in energy and cost. The main objective of this work is to identify and demonstrate possible approaches to improving energy efficiency and reducing operating cost for a dried corn warehouse operator. Three main problems are identified: (i relatively high fuel consumption for internal transfer process, (ii low quality of dried corn, and (iii excess expenditure on outbound transportation. Solutions are proposed and implemented using logistics operations. Improvement is achieved using plant layout and shortest path techniques, resulting in a reduction of almost 50% in energy consumption for the internal transfer process. Installation of an air distributor in the grain storage unit results in a decrease in loss due to poor-quality dried corn from 17% to 10%. Excess expenditure on dried corn distribution is reduced by 6% with application of a global positioning system.

  7. On the concept of critical surface excess of micellization.

    Science.gov (United States)

    Talens-Alesson, Federico I

    2010-11-16

    The critical surface excess of micellization (CSEM) should be regarded as the critical condition for micellization of ionic surfactants instead of the critical micelle concentration (CMC). There is a correspondence between the surface excesses Γ of anionic, cationic, and zwitterionic surfactants at their CMCs, which would be the CSEM values, and the critical association distance for ionic pair association calculated using Bjerrum's correlation. Further support to this concept is given by an accurate method for the prediction of the relative binding of alkali cations onto dodecylsulfate (NaDS) micelles. This method uses a relative binding strength parameter calculated from the values of surface excess Γ at the CMC of the alkali dodecylsulfates. This links both the binding of a given cation onto micelles and the onset for micellization of its surfactant salt. The CSEM concept implies that micelles form at the air-water interface unless another surface with greater affinity for micelles exists. The process would start when surfactant monomers are close enough to each other for ionic pairing with counterions and the subsequent assembly of these pairs becomes unavoidable. This would explain why the surface excess Γ values of different surfactants are more similar than their CMCs: the latter are just the bulk phase concentrations in equilibrium with chemicals with different hydrophobicity. An intriguing implication is that CSEM values may be used to calculate the actual critical distances of ionic pair formation for different cations, replacing Bjerrum's estimates, which only discriminate by the magnitude of the charge.

  8. Trajectory Assessment and Modification Tools for Next Generation Air Traffic Management Operations

    Science.gov (United States)

    Brasil, Connie; Lee, Paul; Mainini, Matthew; Lee, Homola; Lee, Hwasoo; Prevot, Thomas; Smith, Nancy

    2011-01-01

    This paper reviews three Next Generation Air Transportation System (NextGen) based high fidelity air traffic control human-in-the-loop (HITL) simulations, with a focus on the expected requirement of enhanced automated trajectory assessment and modification tools to support future air traffic flow management (ATFM) planning positions. The simulations were conducted at the National Aeronautics and Space Administration (NASA) Ames Research Centers Airspace Operations Laboratory (AOL) in 2009 and 2010. The test airspace for all three simulations assumed the mid-term NextGenEn-Route high altitude environment utilizing high altitude sectors from the Kansas City and Memphis Air Route Traffic Control Centers. Trajectory assessment, modification and coordination decision support tools were developed at the AOL in order to perform future ATFM tasks. Overall tool usage results and user acceptability ratings were collected across three areas of NextGen operatoins to evaluate the tools. In addition to the usefulness and usability feedback, feasibility issues, benefits, and future requirements were also addressed. Overall, the tool sets were rated very useful and usable, and many elements of the tools received high scores and were used frequently and successfully. Tool utilization results in all three HITLs showed both user and system benefits including better airspace throughput, reduced controller workload, and highly effective communication protocols in both full Data Comm and mixed-equipage environments.

  9. Applied patent RFID systems for building reacting HEPA air ventilation system in hospital operation rooms.

    Science.gov (United States)

    Lin, Jesun; Pai, Jar-Yuan; Chen, Chih-Cheng

    2012-12-01

    RFID technology, an automatic identification and data capture technology to provide identification, tracing, security and so on, was widely applied to healthcare industry in these years. Employing HEPA ventilation system in hospital is a way to ensure healthful indoor air quality to protect patients and healthcare workers against hospital-acquired infections. However, the system consumes lots of electricity which cost a lot. This study aims to apply the RFID technology to offer a unique medical staff and patient identification, and reacting HEPA air ventilation system in order to reduce the cost, save energy and prevent the prevalence of hospital-acquired infection. The system, reacting HEPA air ventilation system, contains RFID tags (for medical staffs and patients), sensor, and reacting system which receives the information regarding the number of medical staff and the status of the surgery, and controls the air volume of the HEPA air ventilation system accordingly. A pilot program was carried out in a unit of operation rooms of a medical center with 1,500 beds located in central Taiwan from Jan to Aug 2010. The results found the air ventilation system was able to function much more efficiently with less energy consumed. Furthermore, the indoor air quality could still keep qualified and hospital-acquired infection or other occupational diseases could be prevented.

  10. Predictors of excessive use of social media and excessive online gaming in Czech teenagers.

    Science.gov (United States)

    Spilková, Jana; Chomynová, Pavla; Csémy, Ladislav

    2017-12-01

    Background and aims Young people's involvement in online gaming and the use of social media are increasing rapidly, resulting in a high number of excessive Internet users in recent years. The objective of this paper is to analyze the situation of excessive Internet use among adolescents in the Czech Republic and to reveal determinants of excessive use of social media and excessive online gaming. Methods Data from secondary school students (N = 4,887) were collected within the 2015 European School Survey Project on Alcohol and Other Drugs. Logistic regression models were constructed to describe the individual and familial discriminative factors and the impact of the health risk behavior of (a) excessive users of social media and (b) excessive players of online games. Results The models confirmed important gender-specific distinctions - while girls are more prone to online communication and social media use, online gaming is far more prevalent among boys. The analysis did not indicate an influence of family composition on both the excessive use of social media and on excessive online gaming, and only marginal effects for the type of school attended. We found a connection between the excessive use of social media and binge drinking and an inverse relation between excessive online gaming and daily smoking. Discussion and conclusion The non-existence of significant associations between family environment and excessive Internet use confirmed the general, widespread of this phenomenon across the social and economic strata of the teenage population, indicating a need for further studies on the topic.

  11. Operational design and pressure response of large-scale compressed air energy storage in porous formations

    Science.gov (United States)

    Wang, Bo; Bauer, Sebastian

    2017-04-01

    With the rapid growth of energy production from intermittent renewable sources like wind and solar power plants, large-scale energy storage options are required to compensate for fluctuating power generation on different time scales. Compressed air energy storage (CAES) in porous formations is seen as a promising option for balancing short-term diurnal fluctuations. CAES is a power-to-power energy storage, which converts electricity to mechanical energy, i.e. highly pressurized air, and stores it in the subsurface. This study aims at designing the storage setup and quantifying the pressure response of a large-scale CAES operation in a porous sandstone formation, thus assessing the feasibility of this storage option. For this, numerical modelling of a synthetic site and a synthetic operational cycle is applied. A hypothetic CAES scenario using a typical anticline structure in northern Germany was investigated. The top of the storage formation is at 700 m depth and the thickness is 20 m. The porosity and permeability were assumed to have a homogenous distribution with a value of 0.35 and 500 mD, respectively. According to the specifications of the Huntorf CAES power plant, a gas turbine producing 321 MW power with a minimum inlet pressure of 43 bars at an air mass flowrate of 417 kg/s was assumed. Pressure loss in the gas wells was accounted for using an analytical solution, which defines a minimum bottom hole pressure of 47 bars. Two daily extraction cycles of 6 hours each were set to the early morning and the late afternoon in order to bypass the massive solar energy production around noon. A two-year initial filling of the reservoir with air and ten years of daily cyclic operation were numerically simulated using the Eclipse E300 reservoir simulator. The simulation results show that using 12 wells the storage formation with a permeability of 500 mD can support the required 6-hour continuous power output of 321MW, which corresponds an energy output of 3852 MWh per

  12. DIRECT AIR BLAST EXPOSURE EFFECTS IN ANIMALS, OPERATION UPSHOT-KNOTHOLE, PROJECT 4.2

    Energy Technology Data Exchange (ETDEWEB)

    DRAEGER, R.H. (UNITED STATES NAVY - DEPARTMENT OF); LEE, R.H. (UNITED STATES NAVY - DEPARTMENT OF)

    1953-12-31

    Project 4.2 was designed to study direct (primary) air blast injury, in animals, from an atomic weapon in the range of 20 to 50 psi under circumstances affording protection against missiles, thermal and ionizing radiation and to estimate the probable direct air blast hazard in man. The pressure levels at which atomic weapons direct air blast injuries occur will determine, to a large extent, the number of blast casualties likely to be encountered. It is probable that fatal overpressures are not reached until well within the range at which indirect (secondary) blast, thermal and ionizing radiation are practically certain to prove fatal. Only in special situations affording partial protection from other injuries are blast injuries likely to be of practical importance. Two animal species of widely different body weights (700 rats and 56 dogs) were exposed, together with air pressure recorders, in aluminum cylinders, covered by sandbags and dirt but open at both ends, at seven stations distributed within the intended overpressure range of 20 to 50 psi of Shot 10« About 200 rats were likewise exposed in Shot 9. Unfortunately, the destructive effect of the air blast of Shot 10 was much greater than anticipated. Many of the exposure cylinders were displaced and their contents destroyed. Only a partial recovery of the animals was possible due to the excessive radioactive contamination which greatly limited the time in the area. Most of the animals were dead upon recovery. Those living were in a state of severe shock. Autopsy findings showed remarkably few traumatic lesions and lung hemorrhages in spite of the rough treatment and high overpressure to which they were subjected. The rats recovered from Shot 9 were exposed to a recorded pressure of 18 to 2k psi. The autopsy findings showed moderate lung hemorrhage in most of the animals undoubtedly due to direct air blast injury. The findings were typical of those seen following exposure to air blast from HE or in the shock

  13. Potential hazards of compressed air energy storage in depleted natural gas reservoirs.

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, Paul W.; Grubelich, Mark Charles; Bauer, Stephen J.

    2011-09-01

    This report is a preliminary assessment of the ignition and explosion potential in a depleted hydrocarbon reservoir from air cycling associated with compressed air energy storage (CAES) in geologic media. The study identifies issues associated with this phenomenon as well as possible mitigating measures that should be considered. Compressed air energy storage (CAES) in geologic media has been proposed to help supplement renewable energy sources (e.g., wind and solar) by providing a means to store energy when excess energy is available, and to provide an energy source during non-productive or low productivity renewable energy time periods. Presently, salt caverns represent the only proven underground storage used for CAES. Depleted natural gas reservoirs represent another potential underground storage vessel for CAES because they have demonstrated their container function and may have the requisite porosity and permeability; however reservoirs have yet to be demonstrated as a functional/operational storage media for compressed air. Specifically, air introduced into a depleted natural gas reservoir presents a situation where an ignition and explosion potential may exist. This report presents the results of an initial study identifying issues associated with this phenomena as well as possible mitigating measures that should be considered.

  14. Energy analysis of under-floor air distribution (UFAD) system: An office building case study

    International Nuclear Information System (INIS)

    Alajmi, Ali F.; Abou-Ziyan, Hosny Z.; El-Amer, Wid

    2013-01-01

    Highlights: • The key issue for efficient performance of UFAD system is to ensure the thermal stratification establishment. • The unnecessarily excess air supplied to the room deteriorates the thermal stratification. • Improper UFAD operation increases the fan power and HVAC electric demand. • The proper UFAD system is typically more efficient than the existed UFAD system with energy savings of about 23–37%. • UFAD system shows over the CBAD system saving by about 37–39% during the peak months and 51% during October. - Abstract: This paper presents the results of an experimental and theoretical investigation to evaluate an under-floor air distribution (UFAD) system existed in an office building working on hot climate. Air temperature a distribution and supply air velocity are measured in two measuring stations; each consists of eight temperature sensors which were installed to measure room air temperatures along zone height. The obtained data shows an inefficient operation of the UFAD system which deteriorates the advantages of energy saving that presumed by UFAD system. The building energy simulation program, EnergyPlus, was used to identify the best setting of UFAD system and compare it with the existed UFAD and the conventional ceiling based air distribution (CBAD) system. The simulation results show that setting of room thermostat at 26 °C and supply air temperature at 18 °C provides the best efficient UFAD system. Due to improper operation of the tested UFAD system, its actual consumption is found to be higher than the best simulated UFAD by 23–37% during July to October. Also, the simulation results show that the HVAC demand of UFAD is lower than CBAD by 37–39% during July–September and 51% in October

  15. Safety-related control air systems

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    This Standard applies to those portions of the control air system that furnish air required to support, control, or operate systems or portions of systems that are safety related in nuclear power plants. This Standard relates only to the air supply system(s) for safety-related air operated devices and does not apply to the safety-related air operated device or to air operated actuators for such devices. The objectives of this Standard are to provide (1) minimum system design requirements for equipment, piping, instruments, controls, and wiring that constitute the air supply system; and (2) the system and component testing and maintenance requirements

  16. Ozone and dinitrogen monoxide production in atmospheric pressure air dielectric barrier discharge plasma effluent generated by nanosecond pulse superimposed alternating current voltage

    Science.gov (United States)

    Takashima, Keisuke; Kaneko, Toshiro

    2017-06-01

    The effects of nanosecond pulse superposition to alternating current voltage (NS + AC) on the generation of an air dielectric barrier discharge (DBD) plasma and reactive species are experimentally studied, along with measurements of ozone (O3) and dinitrogen monoxide (N2O) in the exhausted gas through the air DBD plasma (air plasma effluent). The charge-voltage cycle measurement indicates that the role of nanosecond pulse superposition is to induce electrical charge transport and excess charge accumulation on the dielectric surface following the nanosecond pulses. The densities of O3 and N2O in NS + AC DBD are found to be significantly increased in the plasma effluent, compared to the sum of those densities generated in NS DBD and AC DBD operated individually. The production of O3 and N2O is modulated significantly by the phase in which the nanosecond pulse is superimposed. The density increase and modulation effects by the nanosecond pulse are found to correspond with the electrical charge transport and the excess electrical charge accumulation induced by the nanosecond pulse. It is suggested that the electrical charge transport by the nanosecond pulse might result in the enhancement of the nanosecond pulse current, which may lead to more efficient molecular dissociation, and the excess electrical charge accumulation induced by the nanosecond pulse increases the discharge coupling power which would enhance molecular dissociation.

  17. Good air quality in offices improves productivity

    DEFF Research Database (Denmark)

    Fanger, Povl Ole

    2000-01-01

    Three recent independent studies have documented that the quality of indoor air has a significant and positive influence or? the productivity of office workers. A combined analysis of the results of the three studies shows a significant relationship between productivity and perceived indoor air...... quality. The impact on productivity justifies a much higher indoor air quality than the minimum levels prescribed in present standards and guidelines. One way of providing air of high quality for people to breathe, without involving excessive ventilation rates and energy use, is to provide "personalized...

  18. Good air quality in offices improves productivity

    DEFF Research Database (Denmark)

    Fanger, Povl Ole

    2000-01-01

    Three recent independent studies have documented that the quality of indoor air has a significant and positive influence on the productivity of office workers. A combined analysis of the results of the three studies shows a significant relationship between productivity and perceived indoor air...... quality. The impact on productivity justifies a much higher indoor air quality than the minimum levels prescribed in present standards and guidelines. One way of providing air of high quality for people to breathe, without involving excessive ventilation rates and energy use, is to provide "personalized...

  19. Efficiency assessment of indoor environmental policy for air-conditioned offices in Hong Kong

    International Nuclear Information System (INIS)

    Wong, L.T.; Mui, K.W.

    2009-01-01

    To reduce carbon dioxide (CO 2 ) emissions through thermal energy conservation, air-conditioned offices in the subtropics are recommended to operate within specified ranges of indoor temperature, relative humidity and air velocity. As thermal discomfort leads to productivity loss, some indoor environmental policies for air-conditioned offices in Hong Kong are investigated in this study with relation to thermal energy consumption, CO 2 emissions from electricity use, and productivity loss due to thermal discomfort. Occupant thermal response is specifically considered as an adaptive factor in evaluating the energy consumption and productivity loss. The energy efficiency of an office is determined by the productivity which corresponds to the CO 2 generated. The results found that a policy with little impact on occupant thermal comfort and worker productivity would improve the office efficiency while the one with excessive energy consumption reduction would result in a substantial productivity loss. This study is a useful reference source for evaluating an indoor thermal environmental policy regarding the energy consumption, CO 2 emissions reduction, thermal comfort and productivity loss in air-conditioned offices in subtropical areas.

  20. A simulation study on the operating performance of a solar-air source heat pump water heater

    International Nuclear Information System (INIS)

    Xu Guoying; Zhang Xiaosong; Deng Shiming

    2006-01-01

    A simulation study on the operating performance of a new type of solar-air source heat pump water heater (SAS-HPWH) has been presented. The SAS-HPWH used a specially designed flat-plate heat collector/evaporator with spiral-finned tubes to obtain energy from both solar irradiation and ambient air for hot water heating. Using the meteorological data in Nanjing, China, the simulation results based on 150 L water heating capacity showed that such a SAS-HPWH can heat water up to 55 deg. C efficiently under various weather conditions all year around. In this simulation study, the influences of solar radiation, ambient temperature and compressor capacity on the performance of the SAS-HPWH were analyzed. In order to improve the overall operating performance, the use of a variable-capacity compressor has been proposed

  1. Air pollution in urban area of Foligno (Italy)

    International Nuclear Information System (INIS)

    Peirone, E.; Gubbini, P.; Peppoloni, A.; Pompei, M.; Segoni, M.

    1998-01-01

    This work shows the air pollution levels, based on air's quality laws, detected around the urban area of the city of Foligno (Perugia-Italy)). The preliminary study done, has shown a general result of a good quality of the air, even if there were some excesses of the Attention Levels, during situations not alarming, as these situations occurred in particular conditions, characterized by intense traffic and unfavorable meteorological conditions [it

  2. Air crews - a new group of radiation workers

    International Nuclear Information System (INIS)

    Antic, D.

    1997-01-01

    Air crews on commercial flights are not generally regarded as occupationally exposed radiation workers. The studies show that they may receive radiation doses in excess of the ICRP recommended limits for members of the public. An international approach to this problem could be enforced through IATA and other organizations in commercial air traffic. The results of the analysis for air crews of Yugoslav Airlines are used as example. (author)

  3. Increased Air Temperature during Simulated Autumn Conditions Does Not Increase Photosynthetic Carbon Gain But Affects the Dissipation of Excess Energy in Seedlings of the Evergreen Conifer Jack Pine1[OA

    Science.gov (United States)

    Busch, Florian; Hüner, Norman P.A.; Ensminger, Ingo

    2007-01-01

    Temperature and daylength act as environmental signals that determine the length of the growing season in boreal evergreen conifers. Climate change might affect the seasonal development of these trees, as they will experience naturally decreasing daylength during autumn, while at the same time warmer air temperature will maintain photosynthesis and respiration. We characterized the down-regulation of photosynthetic gas exchange and the mechanisms involved in the dissipation of energy in Jack pine (Pinus banksiana) in controlled environments during a simulated summer-autumn transition under natural conditions and conditions with altered air temperature and photoperiod. Using a factorial design, we dissected the effects of daylength and temperature. Control plants were grown at either warm summer conditions with 16-h photoperiod and 22°C or conditions representing a cool autumn with 8 h/7°C. To assess the impact of photoperiod and temperature on photosynthesis and energy dissipation, plants were also grown under either cold summer (16-h photoperiod/7°C) or warm autumn conditions (8-h photoperiod/22°C). Photosynthetic gas exchange was affected by both daylength and temperature. Assimilation and respiration rates under warm autumn conditions were only about one-half of the summer values but were similar to values obtained for cold summer and natural autumn treatments. In contrast, photosynthetic efficiency was largely determined by temperature but not by daylength. Plants of different treatments followed different strategies for dissipating excess energy. Whereas in the warm summer treatment safe dissipation of excess energy was facilitated via zeaxanthin, in all other treatments dissipation of excess energy was facilitated predominantly via increased aggregation of the light-harvesting complex of photosystem II. These differences were accompanied by a lower deepoxidation state and larger amounts of β-carotene in the warm autumn treatment as well as by changes in

  4. A study of air breathing rockets. 3: Supersonic mode combustors

    Science.gov (United States)

    Masuya, G.; Chinzel, N.; Kudo, K.; Murakami, A.; Komuro, T.; Ishii, S.

    An experimental study was made on supersonic mode combustors of an air breathing rocket engine. Supersonic streams of room-temperature air and hot fuel-rich rocket exhaust were coaxially mixed and burned in a concially diverging duct of 2 deg half-angle. The effect of air inlet Mach number and excess air ratio was investigated. Axial wall pressure distribution was measured to calculate one dimensional change of Mach number and stagnation temperature. Calculated results showed that supersonic combustion occurred in the duct. At the exit of the duct, gas sampling and Pitot pressure measurement was made, from which radial distributions of various properties were deduced. The distribution of mass fraction of elements from rocket exhaust showed poor mixing performance in the supersonic mode combustors compared with the previously investigated cylindrical subsonic mode combustors. Secondary combustion efficiency correlated well with the centerline mixing parameter, but not with Annushkin's non-dimensional combustor length. No major effect of air inlet Mach number or excess air ratio was seen within the range of conditions under which the experiment was conducted.

  5. 75 FR 75463 - Clean Air Act Operating Permit Program; Petition To Object to Title V Permit for Luke Paper...

    Science.gov (United States)

    2010-12-03

    ... ENVIROMENTAL PROTECTION AGENCY [FRL-9234-9] Clean Air Act Operating Permit Program; Petition To Object to Title V Permit for Luke Paper Company, Luke, MD AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of final action. SUMMARY: Pursuant to section 505(b)(2) of the Clean Air Act (CAA), the...

  6. Modeling Anti-Air Warfare With Discrete Event Simulation and Analyzing Naval Convoy Operations

    Science.gov (United States)

    2016-06-01

    W., & Scheaffer, R. L. (2008). Mathematical statistics with applications . Belmont, CA: Cengage Learning. 118 THIS PAGE INTENTIONALLY LEFT BLANK...WARFARE WITH DISCRETE EVENT SIMULATION AND ANALYZING NAVAL CONVOY OPERATIONS by Ali E. Opcin June 2016 Thesis Advisor: Arnold H. Buss Co...REPORT DATE June 2016 3. REPORT TYPE AND DATES COVERED Master’s thesis 4. TITLE AND SUBTITLE MODELING ANTI-AIR WARFARE WITH DISCRETE EVENT

  7. The Cinderella Front: Allied Special Air Operations in Yugoslavia during World War II

    Science.gov (United States)

    1997-03-01

    the 21st Century: An Effect-Based Approach to the Planning Process”, War Theory Coursebook , Air Command and Staff College: Maxwell AFB, 1996, 36. 6...French and other operations allowed. Of all the contextual elements, the leadership and physical environment were perhaps most influential in the...military liaisons to the Partisans and Chetniks and to gather reliable information about their effectiveness.7 The physical environment of Yugoslavia

  8. ACTIVATION PARAMETERS AND EXCESS THERMODYANAMIC ...

    African Journals Online (AJOL)

    Applying these data, viscosity-B-coefficients, activation parameters (Δμ10≠) and (Δμ20≠) and excess thermodynamic functions, viz., excess molar volume (VE), excess viscosity, ηE and excess molar free energy of activation of flow, (GE) were calculated. The value of interaction parameter, d, of Grunberg and Nissan ...

  9. Los Alamos controlled air incinerator upgrade for TRU/mixed waste operations

    International Nuclear Information System (INIS)

    Vavruska, J.S.; Borduin, L.C.; Hutchins, D.A.; Warner, C.L.; Thompson, T.K.

    1989-01-01

    The Los Alamos Controlled Air Incinerator (CAI) is undergoing a major process upgrade to accept Laboratory-generated transuranic (TRU) and TRU mixed wastes on a production basis. In the interim,prior to the scheduled 1992 operation of a new on-site LLW/mixed waste incinerator, the CAI will also be accepting solid and liquid low-level mixed wastes. This paper describes major modifications that have been made to the process to enhance safety and ensure reliability for long-term, routine waste incineration operations. The regulatory requirements leading to operational status of the system are also briefly described. The CAI was developed in the mid-1970s as a demonstration system for volume reduction of TRU combustible solid wastes. It continues as a successful R and D system well into the 1980s during which incineration tests on a wide variety of radioactive and chemical waste forms were performed. In 1985, a DOE directive required Los Alamos to reduce the volume of its TRU waste prior to ultimate placement in the geological repository at the Waste Isolation Pilot Project (WIPP). With only minor modifications to the original process flowsheet, the Los Alamos CAI was judged capable of conversion to a TRU waste operations mode. 9 refs., 1 fig

  10. Better-Than-Visual Technologies for Next Generation Air Transportation System Terminal Maneuvering Area Operations

    Science.gov (United States)

    Prinzel, Lawrence J., III; Bailey, Randall E.; Shelton, Kevin J.; Jones, Denise R.; Kramer, Lynda J.; Arthur, Jarvis J., III; Williams, Steve P.; Barmore, Bryan E.; Ellis, Kyle E.; Rehfeld, Sherri A.

    2011-01-01

    A consortium of industry, academia and government agencies are devising new concepts for future U.S. aviation operations under the Next Generation Air Transportation System (NextGen). Many key capabilities are being identified to enable NextGen, including the concept of Equivalent Visual Operations (EVO) replicating the capacity and safety of today's visual flight rules (VFR) in all-weather conditions. NASA is striving to develop the technologies and knowledge to enable EVO and to extend EVO towards a Better-Than-Visual (BTV) operational concept. The BTV operational concept uses an electronic means to provide sufficient visual references of the external world and other required flight references on flight deck displays that enable VFR-like operational tempos and maintain and improve the safety of VFR while using VFR-like procedures in all-weather conditions. NASA Langley Research Center (LaRC) research on technologies to enable the concept of BTV is described.

  11. Analysis of the influence of operating conditions on fouling rates in fired heaters

    International Nuclear Information System (INIS)

    Morales-Fuentes, A.; Picón-Núñez, M.; Polley, G.T.; Méndez-Díaz, S.

    2014-01-01

    Fouling due to chemical reaction in preheat trains for the processing of crude oil plays a key role in the operation and maintenance costs and on greenhouse emissions to atmosphere in crude processing plants. A preheat train consists of a set of heat transfer units that provide the crude oil stream the required amount of thermal energy to reach its target temperature either by heat recovery or by direct firing. Fired heaters supply external high temperature heating through the burning of fuel which result in complex heat transfer processes due to the large temperature and pressure changes and vaporization that takes place inside the unit. In this work, a thermo-hydraulic analysis of the performance of fired heaters is carried out through the application of commercial software to solve the mathematical models using finite difference methods; the analysis is applied to the crude side of a vertical fired heater in order to evaluate the impact of process conditions such as throughput and crude inlet temperature (CIT) on the fouling that take place at the early stages of operation. Using a fouling rate model based on thermo-hydraulic parameters, fouling rates are predicted assuming steady state operation and clean conditions. Although variations in process conditions are known to influence fouling rates, little work has been done on the subject. In this work excess air and steam injection are studied as a means to mitigate fouling. Results show that throughput reduction brings about a marked increase in the fouling rates. A decrease in CIT affects only the convection zone and it is found that this effect is negligible. In terms of excess air, it is found that although it affects negatively the heater efficiency it can be used to balance heat transfer between the convection and radiation zone in a way that fouling rates are reduced; however this strategy should be considered right from the design stage. Finally it is observed that steam injection is an effective method

  12. Experimental studies of the air hybrid engine charging operation

    OpenAIRE

    Zhao, H; Ma, T; Lee, CY

    2014-01-01

    Over the last few years, theoretical and modelling studies have been carried out on the feasibility and potential of novel mild air hybrid engine concepts based on production components. These mild air hybrid concepts are able to convert vehicle brake energy into pneumatic energy in the form of compressed air stored in the air tank. The compressed air can then be used to crank-start the engine by either injecting and expanding in the cylinder or driving a production air starter. Thus, the reg...

  13. Air-cooled, hydrogen-air fuel cell

    Science.gov (United States)

    Shelekhin, Alexander B. (Inventor); Bushnell, Calvin L. (Inventor); Pien, Michael S. (Inventor)

    1999-01-01

    An air-cooled, hydrogen-air solid polymer electrolyte (SPE) fuel cell with a membrane electrode assembly operatively associated with a fluid flow plate having at least one plate cooling channel extending through the plate and at least one air distribution hole extending from a surface of the cathode flow field into the plate cooling channel.

  14. Hydrodynamic behaviour and comparison of technologies for the removal of excess biomass in gas-phase biofilters.

    Science.gov (United States)

    Mendoza, J A; Prado, O J; Veiga, M C; Kennes, C

    2004-01-01

    The hydrodynamic behaviour of a biofilter fed toluene and packed with an inert carrier was evaluated on start-up and after long-term operation, using both methane and styrene as tracers in Residence Time Distribution experiments. Results indicated some deviation from ideal plug flow behaviour after 2-year operation. It was also observed that the retention time of VOCs gradually increased with time and was significantly longer than the average residence time of the bulk gas phase. Non-ideal hydrodynamic behaviour in packed beds may be due to excess biomass accumulation and affects both reactor modeling and performance. Therefore, several methods were studied for the removal of biomass after long-term biofilter operation: filling with water and draining, backwashing, and air sparging. Several flow rates and temperatures (20-60 degrees C) were applied using either water or different chemicals (NaOH, NaOCl, HTAB) in aqueous solution. Usually, higher flow rates and higher temperatures allowed the removal of more biomass, but the efficiency of biomass removal was highly dependent on the pressure drop reached before the treatment. The filling/draining method was the least efficient for biomass removal, although the treatment did basically not generate any biological inhibition. The efficiency of backwashing and air sparging was relatively similar and was more effective when adding chemicals. However, treatments with chemicals resulted in a significant decrease of the biofilter's performance immediately after applying the treatment, needing periods of several days to recover the original performance. The effect of manually mixing the packing material was also evaluated in duplicate experiments. Quite large amounts of biomass were removed but disruption of the filter bed was observed. Batch assays were performed simultaneously in order to support and quantify the observed inhibitory effects of the different chemicals and temperatures used during the treatments.

  15. Life testing of a low voltage air circuit breaker

    International Nuclear Information System (INIS)

    Subudhi, M.

    1991-01-01

    ADS-416 low voltage air circuit breaker manufacture by Westinghouse was mechanically cycled to identify age-related degradation in various breaker subcomponents, in particular, the power-operating mechanism. This accelerated aging test was performed on one breaker unit for over 36,000 cycles. Three separate pole shafts, one with a 60 degree weld, one with a 120 degree weld and one with a 180 degree weld in the third pole lever were used to characterize the cracking in these welds. In addition, during the testing, three different operating mechanisms and several other parts were replaced as they degraded to an inoperable condition. Of the seven welds on the pole shaft, two were found to be the critical ones whose fracture can result in misalignment problems of the pole levers. These failures, in turn can lead to many other problems with the operating mechanism including the burn-out of coils, excessive wear in certain parts and over-stressed linkages. Furthermore, the limiting service life of a number of subcomponents of the power-operated mechanism, including the operating mechanism itself, were assessed. 1 ref., 3 figs

  16. An Assessment of Civil Tiltrotor Concept of Operations in the Next Generation Air Transportation System

    Science.gov (United States)

    Chung, William W.; Salvano, Dan; Rinehart, David; Young, Ray; Cheng, Victor; Lindsey, James

    2012-01-01

    Based on a previous Civil Tiltrotor (CTR) National Airspace System (NAS) performance analysis study, CTR operations were evaluated over selected routes and terminal airspace configurations assuming noninterference operations (NIO) and runway-independent operations (RIO). This assessment aims to further identify issues associated with these concepts of operations (ConOps), and their dependency on the airspace configuration and interaction with conventional fixed-wing traffic. Safety analysis following a traditional Safety Management System (SMS) methodology was applied to CTR-unique departure and arrival failures in the selected airspace to identify any operational and certification issues. Additional CTR operational cases were then developed to get a broader understanding of issues and gaps that will need to be addressed in future CTR operational studies. Finally, needed enhancements to National Airspace System performance analysis tools were reviewed, and recommendations were made on improvements in these tools that are likely to be required to support future progress toward CTR fleet operations in the Next Generation Air Transportation System (NextGen).

  17. Symptoms of Psychological Distress and Post-Traumatic Stress Disorder in United States Air Force Drone Operators

    Science.gov (United States)

    2014-08-01

    Disorder in United States Air Force “ Drone ” Operators 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S...referred to as “ drones .” Participants were assessed for self-reported sources of occupational stress, levels of clinical distress using the Outcome...providers are discussed. 15. SUBJECT TERMS Stress, drone operator, PTSD, USAF 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT

  18. Comparison between Different Air Distribution Systems

    DEFF Research Database (Denmark)

    Nielsen, Peter V.

    The aim of an air conditioning system is to remove excess heat in a room and replace room air with fresh air to obtain a high air quality. It is not sufficient to remove heat and contaminated air, it is also necessary to distribute and control the air movement in the room to create thermal comfort...... in the occupied zone. Most air distribution systems are based on mixing ventilation with ceiling or wall-mounted diffusers or on displacement ventilation with wall-mounted low velocity diffusers. New principles for room air distribution were introduced during the last decades, as the textile terminals mounted...... in the ceiling and radial diffusers with swirling flow also mounted in the ceiling. This paper addresses five air distribution systems in all, namely mixing ventilation from a wallmounted terminal, mixing ventilation from a ceiling-mounted diffuser, mixing ventilation from a ceiling-mounted diffuser...

  19. Performance evaluation of air cleaning devices of an operating low level radioactive solid waste incinerator

    International Nuclear Information System (INIS)

    Subramanian, V.; Surya Narayana, D.S.; Sundararajan, A.R.; Satyasai, P.M.; Ahmed, Jaleel

    1997-01-01

    Particle removal efficiencies of a cyclone separator, baghouse filters and a high efficiency particulate activity (HEPA) filter bank of an incinerator have been determined during the incineration of combustible low level solid radioactive wastes with surface dose of 20 - 50 gy/h. Experimental runs have been carried out to collect the particulates in various aerodynamic size ranges using an eight stage Andersen sampler and a low pressure impactor (LPI) while the incinerator is in operation. The collection efficiencies of the cyclone, baghouse and HEPA filters have been found to be 100 per cent for particles of size greater than 4.7, 2.1 and 1.1 μm respectively. The results of our investigations indicate that the air cleaning devices of the incinerator are working according to their design criteria. The data will be useful in the design and operation of air cleaning devices for toxic gaseous effluents. (author). 3 refs., 2 figs., 1 tab

  20. Fuel consumption in an air blower for agricultural use under different operating conditions

    OpenAIRE

    Silva, Robson L. da

    2017-01-01

    ABSTRACT Evaluation of fuel consumption in internal combustion engines (ICE) of agricultural machinery and equipment is important in determining the performance under various operating conditions, especially when using biofuels. This study consisted of experimental evaluation of the gasoline (petrol)/ethanol consumption in a two-stroke 1-cylinder ICE, Otto cycle, functioning as an air blower for agriculture and related applications. A methodology for tests of non-automotive ICE, based on ABNT...

  1. Stringy origin of diboson and dijet excesses at the LHC

    Science.gov (United States)

    Anchordoqui, Luis A.; Antoniadis, Ignatios; Goldberg, Haim; Huang, Xing; Lüst, Dieter; Taylor, Tomasz R.

    2015-10-01

    Very recently, the ATLAS and CMS Collaborations reported diboson and dijet excesses above standard model expectations in the invariant mass region of 1.8-2.0 TeV. Interpreting the diboson excess of events in a model independent fashion suggests that the vector boson pair production searches are best described by WZ or ZZ topologies, because states decaying into W+W- pairs are strongly constrained by semileptonic searches. Under the assumption of a low string scale, we show that both the diboson and dijet excesses can be steered by an anomalous U (1) field with very small coupling to leptons. The Drell-Yan bounds are then readily avoided because of the leptophobic nature of the massive Z‧ gauge boson. The non-negligible decay into ZZ required to accommodate the data is a characteristic footprint of intersecting D-brane models, wherein the Landau-Yang theorem can be evaded by anomaly-induced operators involving a longitudinal Z. The model presented herein can be viewed purely field-theoretically, although it is particularly well motivated from string theory. Should the excesses become statistically significant at the LHC13, the associated Zγ topology would become a signature consistent only with a stringy origin.

  2. Influence Of Momentum Excess On The Pattern And Dynamics Of Intermediate-Range Stratified Wakes

    Science.gov (United States)

    2016-06-01

    disturbed by either lack or excess of self-propulsion, a greater perturbation was achieved, particularly in the ocean interior . Discovering the...which can be used on the operational level for developing and improving algorithms for non- acoustic signature prediction and detection. 14. SUBJECT...disturbed by either lack or excess of self-propulsion, a greater perturbation was achieved, particularly in the ocean interior . Discovering the significance

  3. Direct current plasma jet at atmospheric pressure operating in nitrogen and air

    Science.gov (United States)

    Deng, X. L.; Nikiforov, A. Yu.; Vanraes, P.; Leys, Ch.

    2013-01-01

    An atmospheric pressure direct current (DC) plasma jet is investigated in N2 and dry air in terms of plasma properties and generation of active species in the active zone and the afterglow. The influence of working gases and the discharge current on plasma parameters and afterglow properties are studied. The electrical diagnostics show that discharge can be sustained in two different operating modes, depending on the current range: a self-pulsing regime at low current and a glow regime at high current. The gas temperature and the N2 vibrational temperature in the active zone of the jet and in the afterglow are determined by means of emission spectroscopy, based on fitting spectra of N2 second positive system (C3Π-B3Π) and the Boltzmann plot method, respectively. The spectra and temperature differences between the N2 and the air plasma jet are presented and analyzed. Space-resolved ozone and nitric oxide density measurements are carried out in the afterglow of the jet. The density of ozone, which is formed in the afterglow of nitrogen plasma jet, is quantitatively detected by an ozone monitor. The density of nitric oxide, which is generated only in the air plasma jet, is determined by means of mass-spectroscopy techniques.

  4. Evaluation of High Density Air Traffic Operations with Automation for Separation Assurance, Weather Avoidance and Schedule Conformance

    Science.gov (United States)

    Prevot, Thomas; Mercer, Joey S.; Martin, Lynne Hazel; Homola, Jeffrey R.; Cabrall, Christopher D.; Brasil, Connie L.

    2011-01-01

    In this paper we discuss the development and evaluation of our prototype technologies and procedures for far-term air traffic control operations with automation for separation assurance, weather avoidance and schedule conformance. Controller-in-the-loop simulations in the Airspace Operations Laboratory at the NASA Ames Research Center in 2010 have shown very promising results. We found the operations to provide high airspace throughput, excellent efficiency and schedule conformance. The simulation also highlighted areas for improvements: Short-term conflict situations sometimes resulted in separation violations, particularly for transitioning aircraft in complex traffic flows. The combination of heavy metering and growing weather resulted in an increased number of aircraft penetrating convective weather cells. To address these shortcomings technologies and procedures have been improved and the operations are being re-evaluated with the same scenarios. In this paper we will first describe the concept and technologies for automating separation assurance, weather avoidance, and schedule conformance. Second, the results from the 2010 simulation will be reviewed. We report human-systems integration aspects, safety and efficiency results as well as airspace throughput, workload, and operational acceptability. Next, improvements will be discussed that were made to address identified shortcomings. We conclude that, with further refinements, air traffic control operations with ground-based automated separation assurance can routinely provide currently unachievable levels of traffic throughput in the en route airspace.

  5. Excess Entropy and Diffusivity

    Indian Academy of Sciences (India)

    First page Back Continue Last page Graphics. Excess Entropy and Diffusivity. Excess entropy scaling of diffusivity (Rosenfeld,1977). Analogous relationships also exist for viscosity and thermal conductivity.

  6. 24 CFR 236.60 - Excess Income.

    Science.gov (United States)

    2010-04-01

    ... 24 Housing and Urban Development 2 2010-04-01 2010-04-01 false Excess Income. 236.60 Section 236... § 236.60 Excess Income. (a) Definition. Excess Income consists of cash collected as rent from the... Rent. The unit-by-unit requirement necessitates that, if a unit has Excess Income, the Excess Income...

  7. California State Implementation Plan; San Diego County Air Pollution Control District; VOC Emissions from Polyester Resin Operations

    Science.gov (United States)

    EPA is taking final action to approve revisions to the San Diego County Air Pollution Control District (SDCAPCD) portion of the California SIP concerning volatile organic compound (VOC) emissions from polyester resin operations.

  8. Stringy origin of diboson and dijet excesses at the LHC

    CERN Document Server

    Anchordoqui, Luis A; Goldberg, Haim; Huang, Xing; Lust, Dieter; Taylor, Tomasz R

    2015-01-01

    Very recently, the ATLAS and CMS collaborations reported diboson and dijet excesses above standard model expectations in the invariant mass region of 1.8 -2.0 TeV. Interpreting the diboson excess of events in a model independent fashion suggests that the vector boson pair production searches are best described by WZ or ZZ topologies, because states decaying into W^+W^- pairs are strongly constrained by semileptonic searches. We show that both the diboson and dijet excesses can be steered by an anomalous U(1) field with very small coupling to leptons. The Drell-Yan bounds are then readily avoided because of the leptophobic nature of the massive Z' gauge boson. The non-negligible decay into ZZ required to accommodate the data is a characteristic footprint of intersecting D-brane models, wherein the Landau-Yang theorem can be evaded by anomaly-induced operators involving a longitudinal Z. The model presented herein can be viewed purely field-theoretically, although it is particularly well motivated from string t...

  9. Air Traffic Management Technology Demonstration-1 Concept of Operations (ATD-1 ConOps), Version 3.0

    Science.gov (United States)

    Baxley, Brian T.; Johnson, William C.; Scardina, John; Shay, Richard F.

    2016-01-01

    This document describes the goals, benefits, technologies, and procedures of the Concept of Operations (ConOps) for the Air Traffic Management (ATM) Technology Demonstration #1 (ATD-1), and provides an update to the previous versions of the document [ref 1 and ref 2].

  10. Air quality modeling for accountability research: Operational, dynamic, and diagnostic evaluation

    Science.gov (United States)

    Henneman, Lucas R. F.; Liu, Cong; Hu, Yongtao; Mulholland, James A.; Russell, Armistead G.

    2017-10-01

    Photochemical grid models play a central role in air quality regulatory frameworks, including in air pollution accountability research, which seeks to demonstrate the extent to which regulations causally impacted emissions, air quality, and public health. There is a need, however, to develop and demonstrate appropriate practices for model application and evaluation in an accountability framework. We employ a combination of traditional and novel evaluation techniques to assess four years (2001-02, 2011-12) of simulated pollutant concentrations across a decade of major emissions reductions using the Community Multiscale Air Quality (CMAQ) model. We have grouped our assessments in three categories: Operational evaluation investigates how well CMAQ captures absolute concentrations; dynamic evaluation investigates how well CMAQ captures changes in concentrations across the decade of changing emissions; diagnostic evaluation investigates how CMAQ attributes variability in concentrations and sensitivities to emissions between meteorology and emissions, and how well this attribution compares to empirical statistical models. In this application, CMAQ captures O3 and PM2.5 concentrations and change over the decade in the Eastern United States similarly to past CMAQ applications and in line with model evaluation guidance; however, some PM2.5 species-EC, OC, and sulfate in particular-exhibit high biases in various months. CMAQ-simulated PM2.5 has a high bias in winter months and low bias in the summer, mainly due to a high bias in OC during the cold months and low bias in OC and sulfate during the summer. Simulated O3 and PM2.5 changes across the decade have normalized mean bias of less than 2.5% and 17%, respectively. Detailed comparisons suggest biased EC emissions, negative wintertime SO42- sensitivities to mobile source emissions, and incomplete capture of OC chemistry in the summer and winter. Photochemical grid model-simulated O3 and PM2.5 responses to emissions and

  11. Analysis of air safety in the European system of air traffic

    Directory of Open Access Journals (Sweden)

    О.Є. Луппо

    2008-04-01

    Full Text Available  Article describes air traffic safety provision requirements in the Air Traffic Management system of Europe. Consideration of air traffic variation which affecting the air traffic management operations have been reviewed.

  12. A QMU approach for characterizing the operability limits of air-breathing hypersonic vehicles

    International Nuclear Information System (INIS)

    Iaccarino, Gianluca; Pecnik, Rene; Glimm, James; Sharp, David

    2011-01-01

    The operability limits of a supersonic combustion engine for an air-breathing hypersonic vehicle are characterized using numerical simulations and an uncertainty quantification methodology. The time-dependent compressible flow equations with heat release are solved in a simplified configuration. Verification, calibration and validation are carried out to assess the ability of the model to reproduce the flow/thermal interactions that occur when the engine unstarts due to thermal choking. quantification of margins and uncertainty (QMU) is used to determine the safe operation region for a range of fuel flow rates and combustor geometries. - Highlights: → In this work we introduce a method to study the operability limits of hypersonic scramjet engines. → The method is based on a calibrated heat release model. → It accounts explicitly for uncertainties due to flight conditions and model correlations. → We examine changes due to the combustor geometry and fuel injection.

  13. Air Transport and Operations. Proceedings of the Third International Air Transport and Operations Symposium 2012

    NARCIS (Netherlands)

    Curran, R.; Fischer, L.; Pérez, D.; Klein, K.; Hoekstra, J.; Roling, P.; Verhagen, W.J.C.

    2012-01-01

    Air transport must evolve if it is to optimize its value in the 21st century. The mood in the aerospace industry is positive with regard to economic recovery, but the focus in this transitional time must be on sustaining value, without losing sight of environmental and safety priorities

  14. Air Pollution Modeling at Road Sides Using the Operational Street Pollution Model-A Case Study in Hanoi, Vietnam

    DEFF Research Database (Denmark)

    Hung, Ngo Tho; Ketzel, Matthias; Jensen, Steen Solvang

    2010-01-01

    In many metropolitan areas, traffic is the main source of air pollution. The high concentrations of pollutants in streets have the potential to affect human health. Therefore, estimation of air pollution at the street level is required for health impact assessment. This task has been carried out...... in many developed countries by a combination of air quality measurements and modeling. This study focuses on how to apply a dispersion model to cities in the developing world, where model input data and data from air quality monitoring stations are limited or of varying quality. This research uses...... the operational street pollution model (OSPM) developed by the National Environmental Research Institute in Denmark for a case study in Hanoi, the capital of Vietnam. OSPM predictions from five streets were evaluated against air pollution measurements of nitrogen oxides (NO), sulfur dioxide (SO2), carbon monoxide...

  15. Natural convection liquid desiccant loop as an auxiliary air conditioning system: investigating the operational parameters

    Science.gov (United States)

    Fazilati, Mohammad Ali; Alemrajabi, Ali Akbar; Sedaghat, Ahmad

    2018-03-01

    Liquid desiccant air conditioning system with natural convection was presented previously as a new generation of AC systems. The system consists of two three-fluid energy exchangers namely absorber and regenerator in which the action of air dehumidifying and desiccant regeneration is done, respectively. The influence of working parameters on system performance including the heat source and heat sink temperature, concentration of desiccant solution fills the system initially and humidity content of inlet air to regenerator is investigated experimentally. The heat source temperatures of 50 °C and 60 °C, heat sink temperatures of 15 °C and 20 °C and desiccant concentrations of 30% and 34%, are examined here. The inlet air to regenerator has temperature of 38.5 °C and three relative humidity of 14%, 38% and 44%. In all experiments, the inlet air to absorber has temperature of 31 °C and relative humidity of 75%. By inspecting evaluation indexes of system, it is revealed that higher startup desiccant concentration solution is more beneficial for all study cases. It is also observed although the highest/lowest temperature heat source/heat sink is most suitable for best system operation, increasing the heat source temperature should be accompanied with decreasing heat sink temperature. Using drier air stream for regenerator inlet does not necessarily improve system performance; and the air stream with proper value of humidity content should be employed. Finally after running the system in its best working condition, the coefficient of performance (COP) reached 4.66 which verified to be higher than when the same air conditioning task done by a conventional vapor compression system, in which case the COP was 3.38.

  16. Hazardous emissions, operating practices, and air regulations at industrial wood-fired facilities in Wisconsin

    International Nuclear Information System (INIS)

    Hubbard, A.J.

    1993-01-01

    Since October of 1988 the State of Wisconsin Department of Natural Resources has regulated over four hundred substances as hazardous air pollutants. The rule regulates new as well as existing sources of air pollution in Wisconsin. Consequently, all permits to operate an air pollution source in Wisconsin must address the hazardous air emissions potential of the source. While widely perceived as a clean-burning fuel, wood is often burned in a manner which clearly results in significant emissions of very hazardous air pollutants. Research conducted on a 20 million BTU per hour wood-fired spreader stoker boiler in northern Wisconsin showed that this boiler has the potential to emit 0.022 pound of benzene and 0.012 pound of formaldehyde per ton (lb/ton) of wood fired. Recent stack tests at more than a dozen other small industrial wood-fired facilities in Wisconsin show a range of formaldehyde emissions of 0.0007--0.1950 lb/ton. Work at Birchwood Lumber ampersand Veneer showed that the benzene and formaldehyde emission rates under good firing conditions are an order of magnitude lower than the benzene and formaldehyde emission rates under poor firing conditions. This finding has supported Wisconsin's regulatory approach of encouraging wood-fired facilities to enhance the quality of the combustion process as a technique to minimize the hazardous air pollution potential of industrial wood combustion. The Wisconsin strategy is to define open-quotes good combustion technologyclose quotes through easily measurable combustion parameters rather than emission standards. This paper presents several techniques in use in Wisconsin to comply with open-quotes good combustion technologyclose quotes for industrial wood-fired furnaces. These techniques include fuel blending overfire air, furnace insulation, and proper grate design

  17. Defense Finance and Accounting Service Work on the FY 1993 Air Force Defense Business Operations Fund Financial Statements

    National Research Council Canada - National Science Library

    Rau, Russell

    1995-01-01

    Our original audit objective was to determine whether the Air Force Consolidated Defense Business Operations Fund financial statements, prepared by the DFAS Denver Center for FY 1993, were presented...

  18. THE FUTURE OF PASSENGER AIR TRANSPORT – VERY LARGE AIRCRAFT AND OUT KEY HUMAN FACTORS AFFECTING THE OPERATION AND SAFETY OF PASSENGER AIR TRANSPORT

    Directory of Open Access Journals (Sweden)

    Petra Skolilova

    2017-12-01

    Full Text Available The article outlines some human factors affecting the operation and safety of passenger air transport given the massive increase in the use of the VLA. Decrease of the impact of the CO2 world emissions is one of the key goals for the new aircraft design. The main wave is going to reduce the burned fuel. Therefore, the eco-efficiency engines combined with reasonable economic operation of the aircraft are very important from an aviation perspective. The prediction for the year 2030 says that about 90% of people, which will use long-haul flights to fly between big cities. So, the A380 was designed exactly for this time period, with a focus on the right capacity, right operating cost and right fuel burn per seat. There is no aircraft today with better fuel burn combined with eco-efficiency per seat, than the A380. The very large aircrafts (VLAs are the future of the commercial passenger aviation. Operating cost versus safety or CO2 emissions versus increasing automation inside the new generation aircraft. Almost 80% of the world aircraft accidents are caused by human error based on wrong action, reaction or final decision of pilots, the catastrophic failures of aircraft systems, or air traffic control errors are not so frequent. So, we are at the beginning of a new age in passenger aviation and the role of the human factor is more important than ever.

  19. Effect of air ingress on the energy performance of coal fired thermal power plants

    International Nuclear Information System (INIS)

    Siddhartha Bhatt, M.

    2007-01-01

    Ingress of air in boilers leads to drops in energy efficiency. This paper presents the effects of air ingress in the combustion zone, post-combustion zone and air pre-heater (APH) on the energy efficiency and loading capacity of a coal fired thermal power plant operating on fuel with high ash (35-45%). The optimal O 2 in the flue gas for a pulverized coal fired system is 3.5% (corresponding to 20% excess air). The operating values are in the range of 4.2-6.0% in membrane type boilers and up to 10% in refractory type boilers (after sustained periods of operation). The leakage rate of boilers (up to the entrance of the APH) is designed at 0.2% while the average operating values are 7.25% for membrane type enclosures and 33.61% for refractory enclosures. The leakage rate of the APH is designed at 5.0% while the operating values range from 13.66% to 20.13% for rotary and tubular APHs. When the O 2 in the combustion zone varies from 3.5% to 8.0%, efficiency drops of 2.0% points are experienced in the boiler and turbine separately, and the gross overall efficiency drop is ∼3.0% points. The units do not experience any capacity drop up to an O 2 in the flue gas of 6.0% before the APH. At an O 2 in the flue gas (before APH) of 7.2%, a mild limitation on the unit capacity of around 2-3% is experienced. When O 2 in the flue gas (before APH) reaches a level of 9.0%, 20% capacity drop of the unit is experienced due to which the plant load cannot be raised higher than 80%. Beyond the level of 9.0% (rare occurrence), the unit is quite difficult to operate and has to be taken off for overhaul

  20. Formation flying as an innovative air transportation system for long-haul commercial flight : A focus on operational feasibility and potential gain

    NARCIS (Netherlands)

    Herinckx, L.E.; Gutleb, T.L.M.; Van Nunen, R.; Van Rompuy, E.; Bos, D.A.; Dijkers, H.P.A.; De Wit, J.; Radfar, H.; Sahin, S.E.; Beelarts van Blokland, W.W.A.

    2011-01-01

    Formation flying is introduced as a new and innovative air transportation system for long-haul commercial flight. With this paper the operational feasibility of formation flying is addressed, both from a market demand and economic, as well as an air traffic control perspective. Preliminary results

  1. Indoor air bacterial load and antibiotic susceptibility pattern of isolates in operating rooms and surgical wards at jimma university specialized hospital, southwest ethiopia.

    Science.gov (United States)

    Genet, Chalachew; Kibru, Gebre; Tsegaye, Wondewosen

    2011-03-01

    Surgical site infection is the second most common health care associated infection. One of the risk factors for such infection is bacterial contamination of operating rooms' and surgical wards' indoor air. In view of that, the microbiological quality of air can be considered as a mirror of the hygienic condition of these rooms. Thus, the objective of this study was to determine the bacterial load and antibiotic susceptibility pattern of isolates in operating rooms' and surgical wards' indoor air of Jimma University Specialized Hospital. A cross sectional study was conducted to measure indoor air microbial quality of operating rooms and surgical wards from October to January 2009/2010 on 108 indoor air samples collected in twelve rounds using purposive sampling technique by Settle Plate Method (Passive Air Sampling following 1/1/1 Schedule). Sample processing and antimicrobial susceptibility testing were done following standard bacteriological techniques. The data was analyzed using SPSS version 16 and interpreted according to scientifically determined baseline values initially suggested by Fisher. The mean aerobic colony counts obtained in OR-1(46cfu/hr) and OR-2(28cfu/hr) was far beyond the set 5-8cfu/hr acceptable standards for passive room. Similarly the highest mean aerobic colony counts of 465cfu/hr and 461cfu/hr were observed in Female room-1 and room-2 respectively when compared to the acceptable range of 250-450cfu/hr. In this study only 3 isolates of S. pyogenes and 48 isolates of S. aureus were identified. Over 66% of S. aureus was identified in Critical Zone of Operating rooms. All isolates of S. aureus showed 100% and 82.8% resistance to methicillin and ampicillin respectively. Higher degree of aerobic bacterial load was measured from operating rooms' and surgical wards' indoor air. Reducing foot trafficking, improving the ventilation system and routine cleaning has to be made to maintain the aerobic bacteria load with in optimal level.

  2. Stringy origin of diboson and dijet excesses at the LHC

    Directory of Open Access Journals (Sweden)

    Luis A. Anchordoqui

    2015-10-01

    Full Text Available Very recently, the ATLAS and CMS Collaborations reported diboson and dijet excesses above standard model expectations in the invariant mass region of 1.8–2.0 TeV. Interpreting the diboson excess of events in a model independent fashion suggests that the vector boson pair production searches are best described by WZ or ZZ topologies, because states decaying into W+W− pairs are strongly constrained by semileptonic searches. Under the assumption of a low string scale, we show that both the diboson and dijet excesses can be steered by an anomalous U(1 field with very small coupling to leptons. The Drell–Yan bounds are then readily avoided because of the leptophobic nature of the massive Z′ gauge boson. The non-negligible decay into ZZ required to accommodate the data is a characteristic footprint of intersecting D-brane models, wherein the Landau–Yang theorem can be evaded by anomaly-induced operators involving a longitudinal Z. The model presented herein can be viewed purely field-theoretically, although it is particularly well motivated from string theory. Should the excesses become statistically significant at the LHC13, the associated Zγ topology would become a signature consistent only with a stringy origin.

  3. An analysis of post-traumatic stress symptoms in United States Air Force drone operators.

    Science.gov (United States)

    Chappelle, Wayne; Goodman, Tanya; Reardon, Laura; Thompson, William

    2014-06-01

    Remotely piloted aircraft (RPA), commonly referred to as "drones," have emerged over the past decade as an innovative warfighting tool. Given there is a paucity of empirical research assessing drone operators, the purpose of this study was to assess for the prevalence of PTSD symptoms among this cohort. Of the 1084 United States Air Force (USAF) drone operators that participated, a total of 4.3% endorsed a pattern of symptoms of moderate to extreme level of severity meeting criteria outlined in the Diagnostic and Statistical Manual of Mental Disorders-4th edition. The incidence of PTSD among USAF drone operators in this study was lower than rates of PTSD (10-18%) among military personnel returning from deployment but higher than incidence rates (less than 1%) of USAF drone operators reported in electronic medical records. Although low PTSD rates may be promising, limitations to this study are discussed. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. 34 CFR 300.16 - Excess costs.

    Science.gov (United States)

    2010-07-01

    ... 34 Education 2 2010-07-01 2010-07-01 false Excess costs. 300.16 Section 300.16 Education... DISABILITIES General Definitions Used in This Part § 300.16 Excess costs. Excess costs means those costs that... for an example of how excess costs must be calculated.) (Authority: 20 U.S.C. 1401(8)) ...

  5. Safety-related control air systems - approved 1977

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    This standard applies to those portions of the control air system that furnish air required to support, control, or operate systems or portions of systems that are safety related in nuclear power plants. This standard relates only to the air supply system(s) for safety-related air operated devices and does not apply to the safety-related air operated device or to air operated actuators for such devices. The objectives of this standard are to provide (1) minimum system design requirements for equipment, piping, instruments, controls, and wiring that constitute the air supply system; and (2) the system and component testing and maintenance requirements

  6. Study on a self diagnostic monitoring system for an air-operated valve: development of a fault library

    International Nuclear Information System (INIS)

    Chai, Jang Bom; Kim, Yun Chul; Kim, Woo Shik; Cho, Hang Duke

    2004-01-01

    In the interest of nuclear power plant safety, a Self-Diagnostic Monitoring System (SDMS) is needed to monitor defects in safety-related components. An Air-Operated Valve (AOV) is one of the components to be monitored since the failure of its operation could potentially have catastrophic consequences. In this paper, a model of the AOV is developed with the parameters that affect the operational characteristics. The model is useful for both understanding the operation and correlating parameters and defects. Various defects are introduced in the experiments to construct a fault library, which will be used in a pattern recognition approach. Finally, the validity of the fault library is examined

  7. Storage of LWR spent fuel in air: Volume 1: Design and operation of a spent fuel oxidation test facility

    International Nuclear Information System (INIS)

    Thornhill, C.K.; Campbell, T.K.; Thornhill, R.E.

    1988-12-01

    This report describes the design and operation and technical accomplishments of a spent-fuel oxidation test facility at the Pacific Northwest Laboratory. The objective of the experiments conducted in this facility was to develop a data base for determining spent-fuel dry storage temperature limits by characterizing the oxidation behavior of light-water reactor (LWR) spent fuels in air. These data are needed to support licensing of dry storage in air as an alternative to spent-fuel storage in water pools. They are to be used to develop and validate predictive models of spent-fuel behavior during dry air storage in an Independent Spent Fuel Storage Installation (ISFSI). The present licensed alternative to pool storage of spent fuel is dry storage in an inert gas environment, which is called inerted dry storage (IDS). Licensed air storage, however, would not require monitoring for maintenance of an inert-gas environment (which IDS requires) but does require the development of allowable temperature limits below which UO 2 oxidation in breached fuel rods would not become a problem. Scoping tests at PNL with nonirradiated UO 2 pellets and spent-fuel fragment specimens identified the need for a statistically designed test matrix with test temperatures bounding anticipated maximum acceptable air-storage temperatures. This facility was designed and operated to satisfy that need. 7 refs

  8. Fungal endophthalmitis caused by Paecilomyces variotii following cataract surgery: a presumed operating room air-conditioning system contamination.

    Science.gov (United States)

    Tarkkanen, Ahti; Raivio, Virpi; Anttila, Veli-Jukka; Tommila, Petri; Ralli, Reijo; Merenmies, Lauri; Immonen, Ilkka

    2004-04-01

    To report a case of delayed fungal endophthalmitis by Paecilomyces variotii following uncomplicated cataract surgery. To our knowledge this is the first reported case of postoperative endophthalmitis by this species. We report the longterm clinical follow-up of an 83-year-old female who underwent uncomplicated sutureless, small-incision cataract surgery. She developed recurring uveitis 4 months after surgery. Vitreous tap and finally complete vitrectomy with removal of the capsular bag including the intraocular lens were performed. Fungi were studied by histopathology and culture. At histopathological examination, the fungi were found to be closely related with the capsular bag. A few mononuclear inflammatory cells were encountered. At culture, Paecilomyces variotii, a common ubiquitous non-pathogenic saprophyte, was identified. Despite systemic, intravitreal and topical antifungal therapy after vitrectomy the uveitis recurred several times, but no fungal organisms were isolated from the repeat intraocular specimen. At 18 months postoperatively the subject's visual acuity was finger counting at 2 metres. At the time of surgery the operating room air-conditioning system was undergoing repairs. Cases of fungal endophthalmitis after contamination from air-conditioning ventilation systems have been reported before, but none of the cases reported have been caused by P. variotii. P. variotii, a non-pathogenic environmental saprophyte, may be disastrous if introduced into the eye. International recommendations on the environmental control of the operating room air-conditioning ventilation system should be strictly followed. No intraoperative surgery should be undertaken while the air-conditioning system is undergoing repairs or service.

  9. An introduction to the design, commissioning and operation of nuclear air cleaning systems for Qinshan Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Xinliang Chen; Jiangang Qu; Minqi Shi [Shanghai Nuclear Engineering Research and Design Institute (China)] [and others

    1995-02-01

    This paper introduces the design evolution, system schemes and design and construction of main nuclear air cleaning components such as HEPA filter, charcoal adsorber and concrete housing etc. for Qinshan 300MW PWR Nuclear Power Plant (QNPP), the first indigenously designed and constructed nuclear power plant in China. The field test results and in-service test results, since the air cleaning systems were put into operation 18 months ago, are presented and evaluated. These results demonstrate that the design and construction of the air cleaning systems and equipment manufacturing for QNPP are successful and the American codes and standards invoked in design, construction and testing of nuclear air cleaning systems for QNPP are applicable in China. The paper explains that the leakage rate of concrete air cleaning housings can also be assured if sealing measures are taken properly and embedded parts are designed carefully in the penetration areas of the housing and that the uniformity of the airflow distribution upstream the HEPA filters can be achieved generally no matter how inlet and outlet ducts of air cleaning unit are arranged.

  10. Ventilating Air-Conditioner

    Science.gov (United States)

    Dinh, Khanh

    1994-01-01

    Air-conditioner provides ventilation designed to be used alone or incorporated into cooling or heating system operates efficiently only by recirculating stale air within building. Energy needed to operate overall ventilating cooling or heating system slightly greater than operating nonventilating cooling or heating system. Helps to preserve energy efficiency while satisfying need for increased forced ventilation to prevent accumulation of undesired gases like radon and formaldehyde. Provides fresh treated air to variety of confined spaces: hospital surgeries, laboratories, clean rooms, and printing shops and other places where solvents used. In mobile homes and portable classrooms, eliminates irritant chemicals exuded by carpets, panels, and other materials, ensuring healthy indoor environment for occupants.

  11. Diagnosis of excessive vibration signals of two-pole generator rotors in balancing

    International Nuclear Information System (INIS)

    Park, Jong Po

    2000-01-01

    Cause of excessive vibration with twice the rotational speed of a two-pole generator rotor for the fossil power plants was investigated. The two-pole generator rotor, treated as a typically asymmetric rotor in vibration analysis, produces asynchronous vibration with twice the rotational speed, sub-harmonic critical speeds, and potentially unstable operating zones due to its own inertia and/or stiffness asymmetry. This paper introduces a practical balancing procedure, and presents the results of the investigation on sources of the excessive vibration based on the experimental vibration data of the asymmetric two-pole rotor in balancing

  12. Radiation dose estimates due to air particulate emissions from selected phosphate industry operations

    International Nuclear Information System (INIS)

    Partridge, J.E.; Horton, T.R.; Sensintaffar, E.L.; Boysen, G.A.

    1978-06-01

    The EPA Office of Radiation Programs has conducted a series of studies to determine the radiological impact of the phosphate mining and milling industry. This report describes the efforts to estimate the radiation doses due to airborne emissions of particulates from selected phosphate milling operations in Florida. Two wet process phosphoric acid plants and one ore drying facility were selected for this study. The 1976 Annual Operations/Emissions Report, submitted by each facility to the Florida Department of Environmental Regulation, and a field survey trip by EPA personnel to each facility were used to develop data for dose calculations. The field survey trip included sampling for stack emissions and ambient air samples collected in the general vicinity of each plant. Population and individual radiation dose estimates are made based on these sources of data

  13. A dynamic switching strategy for air-conditioning systems operated in light-thermal-load conditions

    International Nuclear Information System (INIS)

    Lin, Jin-Long; Yeh, T.-J.; Hwang, Wei-Yang

    2009-01-01

    Recently, modern air-conditioners have begun to incorporate variable-speed compressors and variable-opening expansion valves, together with feedback control to improve the performance and energy efficiency. However, for the compressor there usually exists a low-speed limit below which its speed can not be continuously modulated unless it is completely turned off. When the air-conditioning system is operated in light-thermal-load conditions, the low-speed limit causes the compressor to run in an on-off manner which can significantly degrade the performance and efficiency. In this paper, a dynamic switching strategy is proposed for such scenarios. The strategy is basically an integration of a cascading control structure, an intuitive switching strategy, and a dynamic compensator. While the control structure provides the nominal performance, the intuitive switching strategy and the dynamic compensator together can account for the compressor's low-speed limitation. Theoretical analysis reveals that when the output matrix of the dynamic compensator is chosen properly, the proposed strategy can effectively reduce the output error caused by the on-off operation of the compressor. Experiments also demonstrate that the proposed strategy can simultaneously provide better regulation for the indoor temperature and improve the energy efficiency at steady state.

  14. Excessive or unwanted hair in women

    Science.gov (United States)

    Hypertrichosis; Hirsutism; Hair - excessive (women); Excessive hair in women; Hair - women - excessive or unwanted ... Women normally produce low levels of male hormones (androgens). If your body makes too much of this ...

  15. An empirically grounded agent based model for modeling directs, conflict detection and resolution operations in air traffic management.

    Science.gov (United States)

    Bongiorno, Christian; Miccichè, Salvatore; Mantegna, Rosario N

    2017-01-01

    We present an agent based model of the Air Traffic Management socio-technical complex system aiming at modeling the interactions between aircraft and air traffic controllers at a tactical level. The core of the model is given by the conflict detection and resolution module and by the directs module. Directs are flight shortcuts that are given by air controllers to speed up the passage of an aircraft within a certain airspace and therefore to facilitate airline operations. Conflicts between flight trajectories can occur for two main reasons: either the planning of the flight trajectory was not sufficiently detailed to rule out all potential conflicts or unforeseen events during the flight require modifications of the flight plan that can conflict with other flight trajectories. Our model performs a local conflict detection and resolution procedure. Once a flight trajectory has been made conflict-free, the model searches for possible improvements of the system efficiency by issuing directs. We give an example of model calibration based on real data. We then provide an illustration of the capability of our model in generating scenario simulations able to give insights about the air traffic management system. We show that the calibrated model is able to reproduce the existence of a geographical localization of air traffic controllers' operations. Finally, we use the model to investigate the relationship between directs and conflict resolutions (i) in the presence of perfect forecast ability of controllers, and (ii) in the presence of some degree of uncertainty in flight trajectory forecast.

  16. An empirically grounded agent based model for modeling directs, conflict detection and resolution operations in air traffic management.

    Directory of Open Access Journals (Sweden)

    Christian Bongiorno

    Full Text Available We present an agent based model of the Air Traffic Management socio-technical complex system aiming at modeling the interactions between aircraft and air traffic controllers at a tactical level. The core of the model is given by the conflict detection and resolution module and by the directs module. Directs are flight shortcuts that are given by air controllers to speed up the passage of an aircraft within a certain airspace and therefore to facilitate airline operations. Conflicts between flight trajectories can occur for two main reasons: either the planning of the flight trajectory was not sufficiently detailed to rule out all potential conflicts or unforeseen events during the flight require modifications of the flight plan that can conflict with other flight trajectories. Our model performs a local conflict detection and resolution procedure. Once a flight trajectory has been made conflict-free, the model searches for possible improvements of the system efficiency by issuing directs. We give an example of model calibration based on real data. We then provide an illustration of the capability of our model in generating scenario simulations able to give insights about the air traffic management system. We show that the calibrated model is able to reproduce the existence of a geographical localization of air traffic controllers' operations. Finally, we use the model to investigate the relationship between directs and conflict resolutions (i in the presence of perfect forecast ability of controllers, and (ii in the presence of some degree of uncertainty in flight trajectory forecast.

  17. Counting systems characterization for air activity measurements

    International Nuclear Information System (INIS)

    Vijayakumar, B.; Balamurugan, M.; Ravi, P.M.

    2018-01-01

    Air activity measurements are carried out continuously at all the nuclear power plant (NPP) sites both during pre-operational phase and also during operation of nuclear facility. These measurements provide a trend line for the background air activity in the surrounding environments of an operating NPP. Any increase in air activity over the benchmark level becomes very handy to investigate the releases from the station and to give feedback to the operators of NPP about the prevailing air activity levels and their correlation to the plant releases. This paper compiles the results obtained for air filter samples using different counters operating in GM region and also plastic scintillators

  18. Experimental validation of a local dehumidification system based on cold water droplets and air-to-air heat exchanger

    NARCIS (Netherlands)

    Janssen, E.G.O.N.; Hammink, H.A.J.; Hendriksen, L.J.A.M.

    2015-01-01

    Excessive humidity is a problem in Dutch growing circumstances. A traditional solution is heating and natural ventilation. To save energy a number of energy efficient dehumidification methods are developed, like mechanical ventilation with dry outside air or a curtain of cold water droplets. In this

  19. Lifting simulation of an offshore supply vessel considering various operating conditions

    Directory of Open Access Journals (Sweden)

    Dong-Hoon Jeong

    2016-06-01

    Full Text Available Recently, an offshore support vessel is being widely used to install an offshore structure such as a subsea equipment which is laid on its deck. The lifting operation which is one of the installation operations includes lifting off, lifting in the air, splash zone crossing, deep submerging, and finally landing of the structure with an offshore support vessel crane. There are some major considerations during this operation. Especially, when lifting off the structure, if operating conditions such as ocean environmental loads and hoisting (or lowering speed are bad, the excess of tension of wire ropes of the crane and the collision between the offshore support vessel and the structure can be occurred due to the relative motion between them. To solve this problem, this study performs the lifting simulation while the offshore support vessel installs the structure. The simulation includes the calculation of dynamic responses of the offshore support vessel and the equipment, including the wire tension and the collision detection. To check the applicability of the simulation, it is applied to some lifting steps by varying operating conditions. As a result, it is confirmed that the conditions affect the operability of those steps.

  20. Excess Entropy Production in Quantum System: Quantum Master Equation Approach

    Science.gov (United States)

    Nakajima, Satoshi; Tokura, Yasuhiro

    2017-12-01

    For open systems described by the quantum master equation (QME), we investigate the excess entropy production under quasistatic operations between nonequilibrium steady states. The average entropy production is composed of the time integral of the instantaneous steady entropy production rate and the excess entropy production. We propose to define average entropy production rate using the average energy and particle currents, which are calculated by using the full counting statistics with QME. The excess entropy production is given by a line integral in the control parameter space and its integrand is called the Berry-Sinitsyn-Nemenman (BSN) vector. In the weakly nonequilibrium regime, we show that BSN vector is described by ln \\breve{ρ }_0 and ρ _0 where ρ _0 is the instantaneous steady state of the QME and \\breve{ρ }_0 is that of the QME which is given by reversing the sign of the Lamb shift term. If the system Hamiltonian is non-degenerate or the Lamb shift term is negligible, the excess entropy production approximately reduces to the difference between the von Neumann entropies of the system. Additionally, we point out that the expression of the entropy production obtained in the classical Markov jump process is different from our result and show that these are approximately equivalent only in the weakly nonequilibrium regime.

  1. Learning from 25 years of experience with the United States clean air act

    Energy Technology Data Exchange (ETDEWEB)

    Schulze, R.H. [Trinity Consultants Incorporated, Dallas, TX (United States)

    1995-12-31

    Twenty-five years ago, the United States embarked on a quest to attain clean air. President Nixon, in signing the Clean Air Act of 1970, defined clean air as the objective for the `70s. Although enormous progress has been made, much remains to be done. Newly constructed industry is quite clean, but many older facilities continue to operate with antiquated controls. Significant advances have been made in cleaning up the emissions from new automobiles, but two factors have impaired progress. First, cars last longer than they did in 1970, so the average age of the fleet has increased. Second, travel has increased as people have moved to the suburbs. Thus, the emission decreases from clean cars have not been as great as expected. This presentation will address some of the lessons learned from the efforts in the United States to implement clean air programs. In a large number of countries, excessively elaborate studies have been substituted for action programs. Since much is now known about air quality, fairly brief studies can define programs that should be undertaken. What may take longer is developing public support and enthusiasm for improved air quality. In most cases, it is desirable to reduce spending on studies and increase spending on devising and implementing plans, as well as effectively communicating the necessary changes to the public. Balanced spending on studies- and action programs is essential to a sound air quality control program. (author)

  2. Learning from 25 years of experience with the United States clean air act

    Energy Technology Data Exchange (ETDEWEB)

    Schulze, R H [Trinity Consultants Incorporated, Dallas, TX (United States)

    1996-12-31

    Twenty-five years ago, the United States embarked on a quest to attain clean air. President Nixon, in signing the Clean Air Act of 1970, defined clean air as the objective for the `70s. Although enormous progress has been made, much remains to be done. Newly constructed industry is quite clean, but many older facilities continue to operate with antiquated controls. Significant advances have been made in cleaning up the emissions from new automobiles, but two factors have impaired progress. First, cars last longer than they did in 1970, so the average age of the fleet has increased. Second, travel has increased as people have moved to the suburbs. Thus, the emission decreases from clean cars have not been as great as expected. This presentation will address some of the lessons learned from the efforts in the United States to implement clean air programs. In a large number of countries, excessively elaborate studies have been substituted for action programs. Since much is now known about air quality, fairly brief studies can define programs that should be undertaken. What may take longer is developing public support and enthusiasm for improved air quality. In most cases, it is desirable to reduce spending on studies and increase spending on devising and implementing plans, as well as effectively communicating the necessary changes to the public. Balanced spending on studies- and action programs is essential to a sound air quality control program. (author)

  3. Device Performance Improvement of Double-Pass Wire Mesh Packed Solar Air Heaters under Recycling Operation Conditions

    Directory of Open Access Journals (Sweden)

    Chii-Dong Ho

    2016-01-01

    Full Text Available The improvement of device performance of a recycling solar air heater featuring a wire mesh packing was investigated experimentally and theoretically. The application of the wire mesh packing and recycle-effect concept to the present study were proposed aiming to strengthen the convective heat-transfer coefficient due to increased turbulence. Comparisons were made among different designs, including the single-pass, flat-plate double-pass and recycling double-pass wire mesh packed operations. The collector efficiency of the recycling double-pass wire mesh packed solar air heater was much higher than that of the other configurations for various recycle ratios and mass flow rates scenarios. The power consumption increment due to implementing wire mesh in solar air heaters was also discussed considering the economic feasibility. A fairly good agreement between theoretical predictions and experimental measurements was achieved with an analyzed error of 1.07%–9.32%.

  4. Provide good air quality for people and improve their productivity

    DEFF Research Database (Denmark)

    Fanger, Povl Ole

    2000-01-01

    Three recent independent studies have documented that the quality of indoor air has a significant and positive influence on the productivity of office workers. A combined analysis of the results of the three studies shows a significant relationship between productivity and perceived indoor air...... quality. The impact on productivity justifies a much higher indoor air quality than the minimum levels prescribed in present standards and guidelines. One way of providing air of high quality for people to breathe, without involving excessive ventilation rates and energy use, is to provide "personalized...... air" to each individual. The application of this concept is discussed....

  5. Important operational parameters of membrane bioreactor-sludge disintegration (MBR-SD) system for zero excess sludge production.

    Science.gov (United States)

    Yoon, Seong-Hoon

    2003-04-01

    In order to prevent excess sludge production during wastewater treatment, a membrane bioreactor-sludge disintegration (MBR-SD) system has been introduced, where the disintegrated sludge is recycled to the bioreactor as a feed solution. In this study, a mathematical model was developed by incorporating a sludge disintegration term into the conventional activated sludge model and the relationships among the operational parameters were investigated. A new definition of F/M ratio for the MBR-SD system was suggested to evaluate the actual organic loading rate. The actual F/M ratio was expected to be much higher than the apparent F/M ratio in MBR-SD. The kinetic parameters concerning the biodegradability of organics hardly affect the system performance. Instead, sludge solubilization ratio (alpha) in the SD process and particulate hydrolysis rate constant (k(h)) in biological reaction determine the sludge disintegration number (SDN), which is related with the overall economics of the MBR-SD system. Under reasonable alpha and k(h) values, SDN would range between 3 and 5 which means the amount of sludge required to be disintegrated would be 3-5 times higher for preventing a particular amount of sludge production. Finally, normalized sludge disintegration rate (q/V) which is needed to maintain a certain level of MLSS in the MBR-SD system was calculated as a function of F/V ratio.

  6. Excessive growth.

    Science.gov (United States)

    Narayanaswamy, Vasudha; Rettig, Kenneth R; Bhowmick, Samar K

    2008-09-01

    Tall stature and excessive growth syndrome are a relatively rare concern in pediatric practice. Nevertheless, it is important to identify abnormal accelerated growth patterns in children, which may be the clue in the diagnosis of an underlying disorder. We present a case of pituitary gigantism in a 2 1/2-year-old child and discuss the signs, symptoms, laboratory findings, and the treatment. Brief discussions on the differential diagnosis of excessive growth/tall stature have been outlined. Pituitary gigantism is very rare in the pediatrics age group; however, it is extremely rare in a child that is less than 3 years of age. The nature of pituitary adenoma and treatment options in children with this condition have also been discussed.

  7. Study of containment air cooler capacity in steam air environment during accident conditions

    International Nuclear Information System (INIS)

    Kansal, M.; Mohan, N.; Bhawal, R.N.; Bajaj, S.S.

    2002-01-01

    Full text: The air coolers are provided for controlling the temperature in the reactor building during normal operation. These air coolers also serve as the main heat sink for the removal of energy from high enthalpy air-steam mixture expected in reactor building under accident conditions. A subroutine COOLER has been developed to estimate the heat removal rate of the air coolers at high temperature and steam conditions. The subroutine COOLER has been attached with the code PACSR (post accident containment system response) used for containment pressure temperature calculation. The subroutine was validated using design parameters at normal operating condition. A study was done to estimate the heat removal rate for some postulated accident conditions. The study reveals that, under accident conditions, the heat removal rate of air coolers increases several times compared with normal operating conditions

  8. The Director of Mobility Forces' Role in the Command Control of Air Mobility Assets During Humanitarian Relief Operations

    National Research Council Canada - National Science Library

    Bush, Timothy E

    2000-01-01

    ...). Air Force doctrine recommends a command and control (C2) structure that permits the same organizational concept to be used throughout the spectrum of conflict, tailored to suit the specific operational objectives of a Joint Task Force (JFT...

  9. Thermodynamic properties of binary mixtures of tetrahydropyran with pyridine and isomeric picolines: Excess molar volumes, excess molar enthalpies and excess isentropic compressibilities

    International Nuclear Information System (INIS)

    Saini, Neeti; Jangra, Sunil K.; Yadav, J.S.; Sharma, Dimple; Sharma, V.K.

    2011-01-01

    Research highlights: → Densities, ρ and speeds of sound, u of tetrahydropyran (i) + pyridine or α-, β- or γ-picoline (j) binary mixtures at 298.15, 303.15 and 308.15 K and excess molar enthalpies, H E of the same set of mixtures at 308.15 K have been measured as a function of composition. → The observed densities and speeds of sound values have been employed to determine excess molar volumes, V E and excess isentropic compressibilities, κ S E . → Topology of the constituents of mixtures has been utilized (Graph theory) successfully to predict V E , H E and κ S E data of the investigated mixtures. → Thermodynamic data of the various mixtures have also been analyzed in terms of Prigogine-Flory-Patterson (PFP) theory. - Abstract: Densities, ρ and speeds of sound, u of tetrahydropyran (i) + pyridine or α-, β- or γ- picoline (j) binary mixtures at 298.15, 303.15 and 308.15 K and excess molar enthalpies, H E of the same set of mixtures at 308.15 K have been measured as a function of composition using an anton Parr vibrating-tube digital density and sound analyzer (model DSA 5000) and 2-drop micro-calorimeter, respectively. The resulting density and speed of sound data of the investigated mixtures have been utilized to predict excess molar volumes, V E and excess isentropic compressibilities, κ S E . The observed data have been analyzed in terms of (i) Graph theory; (ii) Prigogine-Flory-Patterson theory. It has been observed that V E , H E and κ S E data predicted by Graph theory compare well with their experimental values.

  10. Excess wind power

    DEFF Research Database (Denmark)

    Østergaard, Poul Alberg

    2005-01-01

    Expansion of wind power is an important element in Danish climate change abatement policy. Starting from a high penetration of approx 20% however, momentary excess production will become an important issue in the future. Through energy systems analyses using the EnergyPLAN model and economic...... analyses it is analysed how excess productions are better utilised; through conversion into hydrogen of through expansion of export connections thereby enabling sales. The results demonstrate that particularly hydrogen production is unviable under current costs but transmission expansion could...

  11. Regulating low-NOx and high-burnout deep-air-staging combustion under real-furnace conditions in a 600 MWe down-fired supercritical boiler by strengthening the staged-air effect.

    Science.gov (United States)

    Kuang, Min; Wang, Zhihua; Zhu, Yanqun; Ling, Zhongqian; Li, Zhengqi

    2014-10-21

    A 600 MW(e) down-fired pulverized-coal supercritical boiler, which was equipped with a deep-air-staging combustion system for reducing the particularly high NOx emissions, suffered from the well-accepted contradiction between low NOx emissions and high carbon in fly ash, in addition to excessively high gas temperatures in the hopper that jeopardized the boiler's safe operations. Previous results uncovered that under low-NOx conditions, strengthening the staged-air effect by decreasing the staged-air angle and simultaneously increasing the staged-air damper opening alleviated the aforementioned problems to some extent. To establish low-NOx and high-burnout circumstances and control the aforementioned hopper temperatures, a further staged-air retrofit with horizontally redirecting staged air through an enlarged staged-air slot area was performed to greatly strengthen the staged-air effect. Full-load industrial-size measurements were performed to confirm the availability of this retrofit. The present data were compared with those published results before the retrofit. High NOx emissions, low carbon in fly ah, and high hopper temperatures (i.e., levels of 1036 mg/m(3) at 6% O2, 3.72%, and about 1300 °C, respectively) appeared under the original conditions with the staged-air angle of 45° and without overfire air (OFA) application. Applying OFA and reducing the angle to 20° achieved an apparent NOx reduction and a moderate hopper temperature decrease while a sharp increase in carbon in fly ash (i.e., levels of 878 mg/m(3) at 6% O2, about 1200 °C, and 9.81%, respectively). Fortunately, the present staged-air retrofit was confirmed to be applicable in regulating low-NOx, high-burnout, and low hopper temperature circumstances (i.e., levels of 867 mg/m(3) at 6% O2, 5.40%, and about 1100 °C, respectively).

  12. An air bearing system for small high speed gas turbines

    Science.gov (United States)

    Turner, A. B.; Davies, S. J.; Nimir, Y. L.

    1994-03-01

    This paper describes the second phase of an experimental program concerning the application of air bearings to small turbomachinery test rigs and small gas turbines. The first phase examined externally pressurized (EP) journal bearings, with a novel EP thrust bearing, for application to 'warm air' test rigs, and was entirely successful at rotational speeds in excess of 100,000 rpm. This second phase examined several designs of tilting pad-spiring journal bearings, one with a novel form of externally pressurized pad, but all using the original EP thrust bearing. The designs tested are described, including some oscillogram traces, for tests up to a maximum of 70,000 rpm; the most successful using a carbon pad-titanium beam spring arrangement. The thrust bearing which gave trouble-free operation throughout, is also described. The results of an original experiment to measure the 'runway speed' of a radial inflow turbine are also presented, which show that overspeeds of 58 percent above the design speed can result from free-power turbine coupling failure.

  13. TECHNOLOGIES TO ENHANCE THE OPERATION OF EXISTING NATURAL GAS COMPRESSION INFRASTRUCTURE - MANIFOLD DESIGN FOR CONTROLLING ENGINE AIR BALANCE

    Energy Technology Data Exchange (ETDEWEB)

    Gary D. Bourn; Ford A. Phillips; Ralph E. Harris

    2005-12-01

    This document provides results and conclusions for Task 15.0--Detailed Analysis of Air Balance & Conceptual Design of Improved Air Manifolds in the ''Technologies to Enhance the Operation of Existing Natural Gas Compression Infrastructure'' project. SwRI{reg_sign} is conducting this project for DOE in conjunction with Pipeline Research Council International, Gas Machinery Research Council, El Paso Pipeline, Cooper Compression, and Southern Star, under DOE contract number DE-FC26-02NT41646. The objective of Task 15.0 was to investigate the perceived imbalance in airflow between power cylinders in two-stroke integral compressor engines and develop solutions via manifold redesign. The overall project objective is to develop and substantiate methods for operating integral engine/compressors in gas pipeline service, which reduce fuel consumption, increase capacity, and enhance mechanical integrity.

  14. 75 FR 27572 - Monthly Report of Excess Income and Annual Report of Uses of Excess Income

    Science.gov (United States)

    2010-05-17

    ... Income and Annual Report of Uses of Excess Income AGENCY: Office of the Chief Information Officer, HUD... permitted to retain Excess Income for projects under terms and conditions established by HUD. Owners must request to retain some or all of their Excess Income. The request must be submitted through http://www.pay...

  15. Detectors for alpha particles and X-rays operating in ambient air in pulse counting mode or/and with gas amplification

    International Nuclear Information System (INIS)

    Charpak, G; Benaben, P; Breuil, P; Peskov, V

    2008-01-01

    Ionization chambers working in ambient air in current detection mode are attractive due to their simplicity and low cost and are widely used in several applications such as smoke detection, dosimetry, therapeutic beam monitoring and so on. The aim of this work was to investigate if gaseous detectors can operate in ambient air in pulse counting mode as well as with gas amplification which potentially offers the highest possible sensitivity in applications like alpha particle detection or high energy X-ray photon or electron detection. To investigate the feasibility of this method two types of open- end gaseous detectors were build and successfully tested. The first one was a single wire or multiwire cylindrical geometry detector operating in pulse mode at a gas gain of one (pulse ionization chamber). This detector was readout by a custom made wide -band charge sensitive amplifier able to deal with slow induced signals generated by slow motion of negative and positive ions. The multiwire detector was able to detect alpha particles with an efficiency close to 22%. The second type of an alpha detector was an innovative GEM-like detector with resistive electrodes operating in air in avalanche mode at high gas gains (up to 10 4 ). This detector can also operate in a cascaded mode or being combined with other detectors, for example with MICROMEGAS. This detector was readout by a conventional charge -sensitive amplifier and was able to detect alpha particles with 100% efficiency. This detector could also detect X-ray photons or fast electrons. A detailed comparison between these two detectors is given as well as a comparison with commercially available alpha detectors. The main advantages of gaseous detectors operating in air in a pulse detection mode are their simplicity, low cost and high sensitivity. One of the possible applications of these new detectors is alpha particle background monitors which, due to their low cost can find wide application not only in houses, but

  16. Superconductors with excess quasiparticles

    International Nuclear Information System (INIS)

    Elesin, V.F.; Kopaev, Y.V.

    1981-01-01

    This review presents a systematic kinetic theory of nonequilibrium phenomena in superconductors with excess quasiparticles created by electromagnetic or tunnel injection. The energy distributions of excess quasiparticles and of nonequilibrium phonons, dependence of the order parameter on the power and frequency (or intensity) of the electromagnetic field, magnetic properties of nonequilibrium superconductors, I-V curves of superconductor-insulator-superconductor junctions, and other properties are described in detail. The stability of superconducting states far from thermodynamic equilibrium is investigated and it is shown that characteristic instabilities leading to the formation of nonuniform states of a new type or phase transitions of the first kind are inherent to superconductors with excess quasiparticles. The results are compared with experimental data

  17. 40 CFR 60.3069 - Am I required to apply for and obtain a title V operating permit for my air curtain incinerator...

    Science.gov (United States)

    2010-07-01

    ... title V operating permit for my air curtain incinerator that burns only wood waste, clean lumber, and... and Compliance Times for Other Solid Waste Incineration Units That Commenced Construction On or Before December 9, 2004 Model Rule-Air Curtain Incinerators That Burn Only Wood Waste, Clean Lumber, and Yard...

  18. Experimental study of an air conditioning system to control a greenhouse microclimate

    International Nuclear Information System (INIS)

    Attar, I.; Naili, N.; Khalifa, N.; Hazami, M.; Lazaar, M.; Farhat, A.

    2014-01-01

    Highlights: • Contribution in the control of the greenhouse microclimate for pepper cultivation. • The energy storing in the ground and in the water ensure the greenhouse heating. • The circulation of the cold water in the exchangers ensures the greenhouse cooling. • The system makes the greenhouse appropriate for the pepper cultivation whole year. - Abstract: In this papper, a thermal model is developed to investigate the possibility to use the ground thermal energy for the greenhouse heating or cooling. A control system of the ground heat storing is integrated in a chapel greenhouse located in the premises of the Technology and Research Energy Center, Tunis, Tunisia. Polypropylene capillary heat exchangers, suspended in the air and buried into the ground of the greenhouse, are used to store or destore solar energy excess. During the day, the air-suspended exchangers recuperate the solar energy in excess. This recuperated energy is then stored into the ground through the buried exchangers. At night the stored thermal energy is brought back by the suspended exchangers to heat the greenhouse air. The purpose of this study is to contribute in the greenhouse microclimate control. In order to maintain the greenhouse air temperature at 20 °C, suitable for a defined agriculture, the solar energy and the cold water are respectively used for heating and cooling the greenhouse inside air. The design and construction of a chapel greenhouse equipped with the control system is carried out. The studied system is used, at the same time for; heating, cooling the greenhouse air and storing the solar energy in excess. Experiments were conducted during the years 2012–2013, to evaluate the effectiveness of the control system achieved. The measured values of the greenhouse air temperatures with and without the control system are discussed

  19. An experimental study on defrosting heat supplies and energy consumptions during a reverse cycle defrost operation for an air source heat pump

    International Nuclear Information System (INIS)

    Dong Jiankai; Deng Shiming; Jiang Yiqiang; Xia Liang; Yao Yang

    2012-01-01

    For a space heating air source heat pump (ASHP) unit, when its outdoor coil surface temperature is below both the air dew point temperature and the freezing point of water, frost will form on its outdoor coil surface. Frosting affects its operational performance and energy efficiency. Therefore, periodic defrosting is necessary. Currently, the most widely used standard defrosting method for ASHP units is reverse cycle defrost. The energy that should have been used for space heating is used to melt frost, vaporize the melted frost off outdoor coil surface and heat ambient air during defrosting. It is therefore necessary to study the sources of heat supplies and the end-uses of the heat supplied during a reverse cycle defrost operation. In this paper, firstly, an experimental setup is described and experimental procedures are detailed. This is followed by reporting the experimental results and the evaluation of defrosting efficiency for the experimental ASHP unit. Finally, an evaluation of defrosting heat supplies and energy consumptions during a revere cycle defrost operation for the experimental ASHP unit is presented. The experimental and evaluation results indicated that the heat supply from indoor air contributed to 71.8% of the total heat supplied for defrosting and 59.4% of the supplied energy was used for melting frost. The maximum defrosting efficiency could be up to 60.1%. - Highlights: ► Heat supply and consumption during reverse cycle defrost was experimentally studied. ► Indoor air contributed to >70% of total heat supply when indoor fan was turned on. ► ∼60% of the supplied energy was used for melting frost. ► Alternate heat supply other than indoor air should be explored.

  20. Reducing a solar-assisted air-conditioning system’s energy consumption by applying real-time occupancy sensors and chilled water storage tanks throughout the summer: A case study

    International Nuclear Information System (INIS)

    Rosiek, S.; Batlles, F.J.

    2013-01-01

    Highlights: • We present an innovative occupancy and chilled water storage-based operation mode. • This mode was implemented to the solar-assisted air-conditioning system. • It permits to save 42% of total electrical energy during one cooling period. • It allows storing the excess cooling capacity of the absorption chiller. • It prevents the sudden start/stop (on/off cycles) of the absorption chiller. - Abstract: This study describes an innovative occupancy and chilled-water storage-based operation sequence implemented in a solar-assisted air-conditioning system. The core purpose of this solar-assisted air-conditioning system is to handle the cooling and heating load of the Solar Energy Research Centre (CIESOL), thus minimising its environmental impact. In this study, the cooling mode was investigated with special attention focused on the chilled-water storage circuit. The critical concern is that the solar-assisted air-conditioning system should always operate considering the actual load conditions, not using an abstract maximum load that is predetermined during the system’s design process, which can lead to energy waste during periods of low occupancy. Thus, the fundamental problem is to identify the optimum operation sequence for the solar-assisted air-conditioning system that provides the best energy performance. The significance of this work lies in the demonstration of a new operation strategy that utilises real-time occupancy monitoring and chilled-water storage tanks to improve the efficiency of solar-assisted air-conditioning systems, thereby reducing their electricity consumption. Adopting this strategy resulted in a large energy-saving potential. The results demonstrate that during one cooling period, it is possible to conserve approximately 42% of the total electrical energy consumed by the system prior to the adoption of this operation strategy

  1. Hazardous air pollutant emissions from gas-fired combustion sources: emissions and the effects of design and fuel type

    Energy Technology Data Exchange (ETDEWEB)

    England, G.C.; McGrath, T.P. [GE-Energy and Environmental Research Corp., Irvine, CA (United States); Gilmer, L. [Equilon Enterprises, Bellaire, TX (United States); Seebold, J.G. [Chevron Research and Technology Co., Richmond, CA (United States); Lev-On, M. [ARCO, Los Angeles, CA (United States); Hunt, T. [American Petroleum Institute, Washington, DC (United States)

    2001-07-01

    Air emissions from gas-fired combustion devices such as boilers, process heaters, gas turbines and stationary reciprocating engines contain hazardous air pollutants (HAPs) subjected to consideration under the federal clean air act (CAA). This work presents a recently completed major research project to develop an understanding of HAP emissions from gas-fired boilers and process heaters and new HAP emission factors based on field emission tests of gas-fired external combustion devices used in the petroleum industry. The effect of combustion system design and operating parameters on HAP emissions determined by both field and research tests are discussed. Data from field tests of gas-fired petroleum industry boilers and heaters generally show very low emission levels of organic HAPs. A comparison of the emission data for boilers and process heaters, including units with and without various forms of NO{sub x} emission controls, showed no significant difference in organic HAP emission characteristics due to process or burner design. This conclusion is also supported by the results of research tests with different burner designs. Based on field tests of units fired with natural gas and various petroleum industry process gases and research tests in which gas composition was intentionally varied, organic HAP emissions were not determined to be significantly affected by the gas composition. Research data indicate that elevated organic HAP emission levels are found only under extreme operating conditions (starved air or high excess air combustion) associated with poor combustion. (author)

  2. Hazardous air pollutant emissions from gas-fired combustion sources: emissions and the effects of design and fuel type

    International Nuclear Information System (INIS)

    England, G.C.; McGrath, T.P.; Gilmer, L.; Seebold, J.G.; Lev-On, M.; Hunt, T.

    2001-01-01

    Air emissions from gas-fired combustion devices such as boilers, process heaters, gas turbines and stationary reciprocating engines contain hazardous air pollutants (HAPs) subjected to consideration under the federal clean air act (CAA). This work presents a recently completed major research project to develop an understanding of HAP emissions from gas-fired boilers and process heaters and new HAP emission factors based on field emission tests of gas-fired external combustion devices used in the petroleum industry. The effect of combustion system design and operating parameters on HAP emissions determined by both field and research tests are discussed. Data from field tests of gas-fired petroleum industry boilers and heaters generally show very low emission levels of organic HAPs. A comparison of the emission data for boilers and process heaters, including units with and without various forms of NO x emission controls, showed no significant difference in organic HAP emission characteristics due to process or burner design. This conclusion is also supported by the results of research tests with different burner designs. Based on field tests of units fired with natural gas and various petroleum industry process gases and research tests in which gas composition was intentionally varied, organic HAP emissions were not determined to be significantly affected by the gas composition. Research data indicate that elevated organic HAP emission levels are found only under extreme operating conditions (starved air or high excess air combustion) associated with poor combustion. (author)

  3. Reduced energy reqirement for air conditioning by using air diffusion with air flow from floor to ceiling

    Energy Technology Data Exchange (ETDEWEB)

    Bach, H; Dittes, W; Mangelsdorf, R; Detzer, R; Jungbaeck, E; Fitzner, K; Radtke, W; Soethout, F

    1982-02-01

    The condition of the air in the occupied zone in airconditioned rooms is influenced by the mixing of supply air with room air. When supplying air from the ceiling there is a mixing all over the room, when supplying from the floor or from desks there is a mixing region only in the lower area. Above this their is warm air from which the return air is drawn. For air supply from below the cooling load can be decreased. In combination with the possible enthalpy difference between room air and supply air this decrease of the cooling load influences the necessary air rate. The interdependence of various air conditioning systems and various air temperatures is shown with a computer program. The load factor for various air distribution system at various cooling loads have been measured in a room of (8 x 5)m/sup 2/ x 3m. Experiments in a smaller model room (scale 1:3) showed how the heat was transported from the mixing region to the stratification region. The theoretically gained influence of the supply air jets of the height of the mixing region and on the load rate could be verified by the experiments. For the design of the fresh air rate, experience has been gained by measurements with tracegas (N/sub 2/O) in a third room. In comparing calculations the annual energy consumption has been computed for a building assuming various air conditioning systems and typical operation data. From experience with the existing systems the conclusions have been drawn how air distribution from floor to ceiling can be installed and operated.

  4. OPEN AIR DEMOLITION OF FACILITIES HIGHLY CONTAMINATED WITH PLUTONIUM

    International Nuclear Information System (INIS)

    LLOYD, E.R.

    2007-01-01

    The demolition of highly contaminated plutonium buildings usually is a long and expensive process that involves decontaminating the building to near free- release standards and then using conventional methods to remove the structure. It doesn't, however, have to be that way. Fluor has torn down buildings highly contaminated with plutonium without excessive decontamination. By removing the select source term and fixing the remaining contamination on the walls, ceilings, floors, and equipment surfaces; open-air demolition is not only feasible, but it can be done cheaper, better (safer), and faster. Open-air demolition techniques were used to demolish two highly contaminated buildings to slab-on-grade. These facilities on the Department of Energy's Hanford Site were located in, or very near, compounds of operating nuclear facilities that housed hundreds of people working on a daily basis. To keep the facilities operating and the personnel safe, the projects had to be creative in demolishing the structures. Several key techniques were used to control contamination and keep it within the confines of the demolition area: spraying fixatives before demolition; applying fixative and misting with a fine spray of water as the buildings were being taken down; and demolishing the buildings in a controlled and methodical manner. In addition, detailed air-dispersion modeling was done to establish necessary building and meteorological conditions and to confirm the adequacy of the proposed methods. Both demolition projects were accomplished without any spread of contamination outside the modest buffer areas established for contamination control. Furthermore, personnel exposure to radiological and physical hazards was significantly reduced by using heavy equipment rather than ''hands on'' techniques

  5. Health physics experience in commissioning and operation of radiation and air activity monitoring system at FBTR

    International Nuclear Information System (INIS)

    Raghunath, V.M.; Meenakshisundaram, V.; Viswanathan, S.; Bala Sundar, S.; Jose, M.T.; Suriyamurthy, N.; Ravi, T.; Subramanian, V.

    2001-01-01

    The Radiation and Air Activity Monitoring System (RAAMS) at Fast Breeder Test Reactor (FBTR) is meant to monitor and record the radiation and air activity levels at various potentially active areas in FBTR complex. Health Physics Group, FBTR was associated during commissioning of RAAMS in fixing the alarm settings for the monitors, their relocation and in formulating the surveillance procedures. The areas were surveyed to check for any release of activity for confirming the observed readings during operation of the reactor. In such cases, augmentation of shielding was recommended and was promptly implemented by the station management. The details of the long and fruitful experience gained by the Health Physics Group, FBTR are described in this paper. (author)

  6. The Virtual Diphoton Excess

    CERN Document Server

    Stolarski, Daniel

    2016-01-01

    Interpreting the excesses around 750 GeV in the diphoton spectra to be the signal of a new heavy scalar decaying to photons, we point out the possibility of looking for correlated signals with virtual photons. In particular, we emphasize that the effective operator that generates the diphoton decay will also generate decays to two leptons and a photon, as well as to four leptons, independently of the new resonance couplings to $Z\\gamma$ and $ZZ$. Depending on the relative sizes of these effective couplings, we show that the virtual diphoton component can make up a sizable, and sometimes dominant, contribution to the total $2\\ell \\gamma$ and $4\\ell$ partial widths. We also discuss modifications to current experimental cuts in order to maximize the sensitivity to these virtual photon effects. Finally, we briefly comment on prospects for channels involving other Standard Model fermions as well as more exotic decay possibilities of the putative resonance.

  7. 34 CFR 668.166 - Excess cash.

    Science.gov (United States)

    2010-07-01

    ... the Secretary for the costs the Secretary incurred in providing that excess cash to the institution... 34 Education 3 2010-07-01 2010-07-01 false Excess cash. 668.166 Section 668.166 Education..., DEPARTMENT OF EDUCATION STUDENT ASSISTANCE GENERAL PROVISIONS Cash Management § 668.166 Excess cash. (a...

  8. The effect of low-NOx combustion on residual carbon in fly ash and its adsorption capacity for air entrainment admixtures in concrete

    DEFF Research Database (Denmark)

    Pedersen, Kim Hougaard; Jensen, Anker Degn; Dam-Johansen, Kim

    2010-01-01

    been combusted in an entrained flow reactor to test the impact of changes in operating conditions and fuel type on the AEA adsorption of ash and NOx formation. Increased oxidizing conditions, obtained by improved fuel-air mixing or higher excess air, decreased the AEA requirements of the produced ash......Fly ash from pulverized coal combustion contains residual carbon that can adsorb the air-entraining admixtures (AEAs) added to control the air entrainment in concrete. This is a problem that has increased by the implementation of low-NOx combustion technologies. In this work, pulverized fuel has...... by up to a factor of 25. This was due to a lower carbon content in the ash and a lower specific AEA adsorptivity of the carbon. The latter was suggested to be caused by changes in the adsorption properties of the unburned char and a decreased formation of soot, which was found to have a large AEA...

  9. Estimation of low-potential heat recuperation efficiency of smoke fumes in a condensation heat utilizer under various operation conditions of a boiler and a heating system

    Science.gov (United States)

    Ionkin, I. L.; Ragutkin, A. V.; Luning, B.; Zaichenko, M. N.

    2016-06-01

    For enhancement of the natural gas utilization efficiency in boilers, condensation heat utilizers of low-potential heat, which are constructed based on a contact heat exchanger, can be applied. A schematic of the contact heat exchanger with a humidifier for preheating and humidifying of air supplied in the boiler for combustion is given. Additional low-potential heat in this scheme is utilized for heating of the return delivery water supplied from a heating system. Preheating and humidifying of air supplied for combustion make it possible to use the condensation utilizer for heating of a heat-transfer agent to temperature exceeding the dewpoint temperature of water vapors contained in combustion products. The decision to mount the condensation heat utilizer on the boiler was taken based on the preliminary estimation of the additionally obtained heat. The operation efficiency of the condensation heat utilizer is determined by its structure and operation conditions of the boiler and the heating system. The software was developed for the thermal design of the condensation heat utilizer equipped by the humidifier. Computation investigations of its operation are carried out as a function of various operation parameters of the boiler and the heating system (temperature of the return delivery water and smoke fumes, air excess, air temperature at the inlet and outlet of the condensation heat utilizer, heating and humidifying of air in the humidifier, and portion of the circulating water). The heat recuperation efficiency is estimated for various operation conditions of the boiler and the condensation heat utilizer. Recommendations on the most effective application of the condensation heat utilizer are developed.

  10. Radioactive air emissions from non-uranium mining operations

    International Nuclear Information System (INIS)

    Silhanek, J.S.; Andrews, V.E.

    1981-01-01

    Section 122 of the Clean Air Act Amendments of 1977, Public Law 9595, directed the Administrator of the Environmental Protection Agency to review all relevant information and determine whether emissions of radioactive pollutants into ambient air will cause or contribute to air pollution which may reasonably be anticipated to endanger public health. A section of this document presented a theoretical analysis of the radioactive airborne emissions from several non-uranium mines including iron, copper, zinc, clay, limestone, fluorspar, and phosphate. Since 1978 EPA's Las Vegas Laboratory has been gathering field data on actual radionuclide emissions from these mines to support the earlier theoretical analysis. The purpose of this paper is to present the results of those field measurements in comparison with the assumed values for the theoretical analysis

  11. Air Power's First Among Equals: Why Air Superiority Still Matters

    National Research Council Canada - National Science Library

    Slawson, Andrew T

    2008-01-01

    .... History is replete with examples of successful or failed air superiority campaigns. This paper details air superiority's role in both the Battle of Britain, and the 1967 Six Day War's Operation MOKED...

  12. Robustness of tungsten single atom tips to thermal treatment and air exposure

    Energy Technology Data Exchange (ETDEWEB)

    Vesa, Cristian; Urban, Radovan [Department of Physics, University of Alberta, Edmonton, Alberta, Canada T6G 2G7 (Canada); National Institute for Nanotechnology, National Research Council of Canada, Edmonton, Alberta, Canada T6G 2M9 (Canada); Pitters, Jason L., E-mail: jason.pitters@nrc-cnrc.gc.ca [National Institute for Nanotechnology, National Research Council of Canada, Edmonton, Alberta, Canada T6G 2M9 (Canada); Wolkow, Robert A. [Department of Physics, University of Alberta, Edmonton, Alberta, Canada T6G 2G7 (Canada); National Institute for Nanotechnology, National Research Council of Canada, Edmonton, Alberta, Canada T6G 2M9 (Canada)

    2014-05-01

    Highlights: • W(1 1 1) single atom tips (SATs) were exposed to air. • SATs could be regenerated by field assisted chemical etching after exposure. • Warming procedures to minimize tip contamination were developed. • Degassing temperatures for air exposed tips were established. • Tip faceting occurred when SATs and unetched tips were annealed above 1200 °C. - Abstract: Experiments aimed at assessing the robustness of nitrogen-etched, single-atom tips (SATs) prepared using W(1 1 1) single crystal wire were performed. Our experiments showed that single-atoms tips sustain minimal damage when exposed to atmospheric conditions and can be readily and quickly nitrogen-etched to single-atom tips thereafter. The SATs can be annealed at temperatures up to 1100 °C with minimal shape changes. Moreover, annealing temperatures in excess of 1200 °C resulted in an apex faceting which may prove important in further single-atom tip creation. Procedures for warming of the SATs from operating temperatures of 80 K were also evaluated to determine conditions that limit tip contamination. These results show that SATS could be fabricated in a dedicated vacuum system and subsequently transferred to other instruments where they would undergo a brief conditioning procedure to recover the single-atom apex configuration prior to being subjected to operating conditions.

  13. Improving and monitoring air quality.

    Science.gov (United States)

    DuPont, André

    2018-05-01

    Since the authorization of the Clean Air Act Amendments of 1990, the air quality in the USA has significantly improved because of strong public support. The lessons learned over the last 25 years are being shared with the policy analysts, technical professionals, and scientist who endeavor to improve air quality in their communities. This paper will review how the USA has achieved the "high" standard of air quality that was envisioned in the early 1990s. This document will describe SO 2 gas emission reduction technology and highlight operation of emission monitoring technology. This paper describes the basic process operation of an air pollution control scrubber. A technical review of measures required to operate and maintain a large-scale pollution control system will be described. Also, the author explains how quality assurance procedures in performance of continuous emission monitoring plays a significant role in reducing air pollution.

  14. Excess water dynamics in hydrotalcite: QENS study

    Indian Academy of Sciences (India)

    dynamics of excess water in hydrotalcite sample with varied content of excess water are reported. Translational motion of excess water can be best described by random transla- tional jump diffusion model. The observed increase in translational diffusivity with increase in the amount of excess water is attributed to the ...

  15. A Satellite-Based Multi-Pollutant Index of Global Air Quality

    Science.gov (United States)

    Cooper, Mathew J.; Martin, Randall V.; vanDonkelaar, Aaron; Lamsal, Lok; Brauer, Michael; Brook, Jeffrey R.

    2012-01-01

    Air pollution is a major health hazard that is responsible formillions of annual excess deaths worldwide. Simpleindicators are useful for comparative studies and to asses strends over time. The development of global indicators hasbeen impeded by the lack of ground-based observations in vast regions of the world. Recognition is growing of the need for amultipollutant approach to air quality to better represent human exposure. Here we introduce the prospect of amultipollutant air quality indicator based on observations from satellite remote sensing.

  16. 75 FR 30846 - Monthly Report of Excess Income and Annual Report of Uses of Excess Income (Correction)

    Science.gov (United States)

    2010-06-02

    ... Income and Annual Report of Uses of Excess Income (Correction) AGENCY: Office of the Chief Information.... Project owners are permitted to retain Excess Income for projects under terms and conditions established by HUD. Owners must request to retain some or all of their Excess Income. The request must be...

  17. Life testing of a low voltage air circuit breaker

    International Nuclear Information System (INIS)

    Subudhi, M.; Aggarwal, S.

    1992-01-01

    A DS-416 low voltage air circuit breaker manufactured by Westinghouse was mechanically cycled to identify age-related degradation in the various breaker subcomponents, specifically the power-operated mechanism. This accelerated aging test was performed on one breaker unit for over 36,000 cycles. Three separate pole shafts, one with a 60-degree weld, one with a 120-degree weld, and one with a 180-degree weld in the third pole lever were used to characterize cracking in the welds. In addition, during the testing three different operating mechanisms and several other parts were replaced as they became inoperable. Among the seven welds on the pole shaft, number-sign 1 and number-sign 3 were found to be critical ones whose fracture can result in misalignment of the pole levers. This can lead to problems with the operating mechanism, including the burning of coils, excessive wear in certain parts, and overstressed linkages. Furthermore, the limiting service life of a number of subcomponents of the power-operated mechanism, including the operating mechanism itself, were assessed. Based on these findings, suggestions are provided to alleviate the age-related degradation that could occur as a result of normal closing and opening of the breaker contacts during its service life. Also, cause and effect analyses of various age-related degradation in various breaker parts are discussed

  18. 7 CFR 985.56 - Excess oil.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 8 2010-01-01 2010-01-01 false Excess oil. 985.56 Section 985.56 Agriculture... HANDLING OF SPEARMINT OIL PRODUCED IN THE FAR WEST Order Regulating Handling Volume Limitations § 985.56 Excess oil. Oil of any class in excess of a producer's applicable annual allotment shall be identified as...

  19. Dietary and Pharmacological Intervention to Mitigate the Cardiopulmonary Effects of Air Pollution Toxicity

    Science.gov (United States)

    Background: Human exposure to air pollution has long been associated with excess morbidity and mortality. Although regulatory measures carried out under the “Clean Air Act” have saved millions of lives, there are still hundreds of thousands of people in the U.S. that live in area...

  20. Rise time reduction of thermal actuators operated in air and water through optimized pre-shaped open-loop driving

    International Nuclear Information System (INIS)

    Larsen, T; Doll, J C; Loizeau, F; Pruitt, B L; Hosseini, N; Fantner, G E; Peng, A W; Ricci, A J

    2017-01-01

    Electrothermal actuators have many advantages compared to other actuators used in micro-electro-mechanical systems (MEMS). They are simple to design, easy to fabricate and provide large displacements at low voltages. Low voltages enable less stringent passivation requirements for operation in liquid. Despite these advantages, thermal actuation is typically limited to a few kHz bandwidth when using step inputs due to its intrinsic thermal time constant. However, the use of pre-shaped input signals offers a route for reducing the rise time of these actuators by orders of magnitude. We started with an electrothermally actuated cantilever having an initial 10–90% rise time of 85 μ s in air and 234 μ s in water for a standard open-loop step input. We experimentally characterized the linearity and frequency response of the cantilever when operated in air and water, allowing us to obtain transfer functions for the two cases. We used these transfer functions, along with functions describing desired reduced rise-time system responses, to numerically simulate the required input signals. Using these pre-shaped input signals, we improved the open-loop 10–90% rise time from 85 μ s to 3 μ s in air and from 234 μ s to 5 μ s in water, an improvement by a factor of 28 and 47, respectively. Using this simple control strategy for MEMS electrothermal actuators makes them an attractive alternative to other high speed micromechanical actuators such as piezoelectric stacks or electrostatic comb structures which are more complex to design, fabricate, or operate. (paper)

  1. Rise Time Reduction of Thermal Actuators Operated in Air and Water through Optimized Pre-Shaped Open-Loop Driving.

    Science.gov (United States)

    Larsen, T; Doll, J C; Loizeau, F; Hosseini, N; Peng, A W; Fantner, G; Ricci, A J; Pruitt, B L

    2017-01-01

    Electrothermal actuators have many advantages compared to other actuators used in Micro-Electro-Mechanical Systems (MEMS). They are simple to design, easy to fabricate and provide large displacements at low voltages. Low voltages enable less stringent passivation requirements for operation in liquid. Despite these advantages, thermal actuation is typically limited to a few kHz bandwidth when using step inputs due to its intrinsic thermal time constant. However, the use of pre-shaped input signals offers a route for reducing the rise time of these actuators by orders of magnitude. We started with an electrothermally actuated cantilever having an initial 10-90% rise time of 85 μs in air and 234 μs in water for a standard open-loop step input. We experimentally characterized the linearity and frequency response of the cantilever when operated in air and water, allowing us to obtain transfer functions for the two cases. We used these transfer functions, along with functions describing desired reduced rise-time system responses, to numerically simulate the required input signals. Using these pre-shaped input signals, we improved the open-loop 10-90% rise time from 85 μs to 3 μs in air and from 234 μs to 5 μs in water, an improvement by a factor of 28 and 47, respectively. Using this simple control strategy for MEMS electrothermal actuators makes them an attractive alternative to other high speed micromechanical actuators such as piezoelectric stacks or electrostatic comb structures which are more complex to design, fabricate, or operate.

  2. Position paper -- Continuous air monitor (CAM) acquisition recommendation

    International Nuclear Information System (INIS)

    Hughes, M.E.

    1995-01-01

    The purpose of this position paper is to document the decision not to acquire continuous air monitors (CAM's) from government excess/surplus supplies. The procurement plan for equipment to be acquired for project W-236A, the Multi-Function Waste Tank Facility (MWTF), stipulates that radiation monitoring equipment will be supplied by WHC via the stock retained within the excess/surplus inventory or utilization of procured instruments from canceled projects. Technological advances within the radiation detection industry have ultimately outdated the instruments that are available within the excess/surplus stock. These machines represent the technology of the 1970's era. The CAM models in use or within the excess/surplus supplies are obsolete and have been discontinued by the manufacturer. Therefore, the majority of the excess/surplus CAM's are being reacquired and disassembled by instrument shops for in-house acquisition of spare parts for the instruments that are still presently in-service. It is being recommended by W-236A projects department that the strategy to acquire surplus/excess radiation monitoring devices be modified. The recommendation is to directly procure instruments that are equal to the technology available within this industry

  3. Hygiene guideline for the planning, installation, and operation of ventilation and air-conditioning systems in health-care settings - Guideline of the German Society for Hospital Hygiene (DGKH).

    Science.gov (United States)

    Külpmann, Rüdiger; Christiansen, Bärbel; Kramer, Axel; Lüderitz, Peter; Pitten, Frank-Albert; Wille, Frank; Zastrow, Klaus-Dieter; Lemm, Friederike; Sommer, Regina; Halabi, Milo

    2016-01-01

    Since the publication of the first "Hospital Hygiene Guideline for the implementation and operation of air conditioning systems (HVAC systems) in hospitals" (http://www.krankenhaushygiene.de/informationen/fachinformationen/leitlinien/12) in 2002, it was necessary due to the increase in knowledge, new regulations, improved air-conditioning systems and advanced test methods to revise the guideline. Based on the description of the basic features of ventilation concepts, its hygienic test and the usage-based requirements for ventilation, the DGKH section "Ventilation and air conditioning technology" attempts to provide answers for the major air quality issues in the planning, design and the hygienically safe operation of HVAC systems in rooms of health care.

  4. Influence of the outlet air temperature on the thermohydraulic behaviour of air coolers

    Directory of Open Access Journals (Sweden)

    Đorđević Emila M.

    2003-01-01

    Full Text Available The determination of the optimal process conditions for the operation of air coolers demands a detailed analysis of their thermohydraulic behaviour on the one hand, and the estimation of the operating costs, on the other. One of the main parameters of the thermohydraulic behaviour of this type of equipment, is the outlet air temperature. The influence of the outlet air temperature on the performance of air coolers (heat transfer coefficient overall heat transfer coefficient, required surface area for heat transfer air-side pressure drop, fan power consumption and sound pressure level was investigated in this study. All the computations, using AirCooler software [1], were applied to cooling of the process fluid and the condensation of a multicomponent vapour mixture on two industrial devices of known geometries.

  5. 10 CFR 904.10 - Excess energy.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Excess energy. 904.10 Section 904.10 Energy DEPARTMENT OF ENERGY GENERAL REGULATIONS FOR THE CHARGES FOR THE SALE OF POWER FROM THE BOULDER CANYON PROJECT Power Marketing § 904.10 Excess energy. (a) If excess Energy is determined by the United States to be available...

  6. Emissions from oil and gas operations in the United States and their air quality implications.

    Science.gov (United States)

    Allen, David T

    2016-06-01

    The energy supply infrastructure in the United States has been changing dramatically over the past decade. Increased production of oil and natural gas, particularly from shale resources using horizontal drilling and hydraulic fracturing, made the United States the world's largest producer of oil and natural gas in 2014. This review examines air quality impacts, specifically, changes in greenhouse gas, criteria air pollutant, and air toxics emissions from oil and gas production activities that are a result of these changes in energy supplies and use. National emission inventories indicate that volatile organic compound (VOC) and nitrogen oxide (NOx) emissions from oil and gas supply chains in the United States have been increasing significantly, whereas emission inventories for greenhouse gases have seen slight declines over the past decade. These emission inventories are based on counts of equipment and operational activities (activity factors), multiplied by average emission factors, and therefore are subject to uncertainties in these factors. Although uncertainties associated with activity data and missing emission source types can be significant, multiple recent measurement studies indicate that the greatest uncertainties are associated with emission factors. In many source categories, small groups of devices or sites, referred to as super-emitters, contribute a large fraction of emissions. When super-emitters are accounted for, multiple measurement approaches, at multiple scales, produce similar results for estimated emissions. Challenges moving forward include identifying super-emitters and reducing their emission magnitudes. Work done to date suggests that both equipment malfunction and operational practices can be important. Finally, although most of this review focuses on emissions from energy supply infrastructures, the regional air quality implications of some coupled energy production and use scenarios are examined. These case studies suggest that both

  7. Air and water cooled modulator

    Science.gov (United States)

    Birx, Daniel L.; Arnold, Phillip A.; Ball, Don G.; Cook, Edward G.

    1995-01-01

    A compact high power magnetic compression apparatus and method for delivering high voltage pulses of short duration at a high repetition rate and high peak power output which does not require the use of environmentally unacceptable fluids such as chlorofluorocarbons either as a dielectric or as a coolant, and which discharges very little waste heat into the surrounding air. A first magnetic switch has cooling channels formed therethrough to facilitate the removal of excess heat. The first magnetic switch is mounted on a printed circuit board. A pulse transformer comprised of a plurality of discrete electrically insulated and magnetically coupled units is also mounted on said printed board and is electrically coupled to the first magnetic switch. The pulse transformer also has cooling means attached thereto for removing heat from the pulse transformer. A second magnetic switch also having cooling means for removing excess heat is electrically coupled to the pulse transformer. Thus, the present invention is able to provide high voltage pulses of short duration at a high repetition rate and high peak power output without the use of environmentally unacceptable fluids and without discharging significant waste heat into the surrounding air.

  8. AIRS-only Product on Giovanni for Exploring Up-to-date AIRS Observation and Comparing with AIRS+AMSU Product

    Science.gov (United States)

    Ding, F.; Hearty, T. J., III; Theobald, M.; Vollmer, B.; Wei, J.

    2017-12-01

    The NASA Goddard Earth Sciences Data and Information Services Center (GES DISC) has been the home of processing, archiving, and distribution services for the Atmospheric Infrared Sounder (AIRS) mission since its launch in 2002 for the global observations of the atmospheric state. Giovanni, a web-based application developed by the GES DISC, provides a simple and intuitive way to visualize, analyze, and access vast amounts of Earth science remote sensing data without having to download the data. Most important variables, including temperature and humidity profiles, outgoing longwave radiation, cloud properties, and trace gases, from version 6 AIRS product are available on Giovanni. The AIRS is an instrument suite comprised of a hyperspectral infrared instrument AIRS and two multichannel microwave instruments, the Advanced Microwave Sounding Unit (AMSU) and the Humidity Sounder for Brazil (HSB). As the HSB ceased operation in very early stage of AIRS mission, the AIRS project operates two parallel retrieval algorithms: one using both IR and MW measurements (AIRS+AMSU) and the other using only IR measurements (AIRS-only) for the most time of the mission. The AIRS+AMSU product is better and the variables on Giovanni are from it. However, the generation of AIRS+AMSU product has been suspended since the AMSU instrument anomaly occurred in late 2016. To continue exploring up-to-date AIRS observations, the same set of variables from the AIRS-only product are added on Giovanni by the GES DSIC. This will also support the comparison of AIRS-only with AIRS+AMSU retrievals. In the presentation, we will demonstrate the visualization of AIRS-only product and the plots/statistics of comparison with AIRS+AMSU product using Giovanni.

  9. The US Air Force Aerial Spray Unit: a history of large area disease vector control operations, WWII through Katrina.

    Science.gov (United States)

    Breidenbaugh, Mark; Haagsma, Karl

    2008-01-01

    The US Air Force has had a long history of aerial applications of pesticides to fulfill a variety of missions, the most important being the protection of troops through the minimization of arthropod vectors capable of disease transmission. Beginning in World War II, aerial application of pesticides by the military has effectively controlled vector and nuisance pest populations in a variety of environments. Currently, the military aerial spray capability resides in the US Air Force Reserve (USAFR), which operates and maintains C-130 airplanes capable of a variety of missions, including ultra low volume applications for vector and nuisance pests, as well as higher volume aerial applications of herbicides and oil-spill dispersants. The USAFR aerial spray assets are the only such fixed-wing aerial spray assets within the Department of Defense. In addition to troop protection, the USAFR Aerial Spray Unit has participated in a number of humanitarian/relief missions, most recently in the response to the 2005 Hurricanes Katrina and Rita, which heavily damaged the Gulf Coasts of Louisiana, Mississippi, and Texas. This article provides historical background on the Air Force Aerial Spray Unit and describes the operations in Louisiana in the aftermath of Hurricane Katrina.

  10. International Space Station Common Cabin Air Assembly Condensing Heat Exchanger Hydrophilic Coating Operation, Recovery, and Lessons Learned

    Science.gov (United States)

    Balistreri, Steven F.; Steele, John W.; Caron, Mark E.; Laliberte, Yvon J.; Shaw, Laura A.

    2013-01-01

    The ability to control the temperature and humidity of an environment or habitat is critical for human survival. These factors are important to maintaining human health and comfort, as well as maintaining mechanical and electrical equipment in good working order to support the human and to accomplish mission objectives. The temperature and humidity of the International Space Station (ISS) United States On-orbit Segment (USOS) cabin air is controlled by the Common Cabin Air Assembly (CCAA). The CCAA consists of a fan, a condensing heat exchanger (CHX), an air/water separator, temperature and liquid sensors, and electrical controlling hardware and software. The CHX is the primary component responsible for control of temperature and humidity. The CCAA CHX contains a chemical coating that was developed to be hydrophilic and thus attract water from the humid influent air. This attraction forms the basis for water removal and therefore cabin humidity control. However, there have been several instances of CHX coatings becoming hydrophobic and repelling water. When this behavior is observed in an operational CHX in the ISS segments, the unit s ability to remove moisture from the air is compromised and the result is liquid water carryover into downstream ducting and systems. This water carryover can have detrimental effects on the ISS cabin atmosphere quality and on the health of downstream hardware. If the water carryover is severe and widespread, this behavior can result in an inability to maintain humidity levels in the USOS. This paper will describe the operation of the five CCAAs within the USOS, the potential causes of the hydrophobic condition, and the impacts of the resulting water carryover to downstream systems. It will describe the history of this behavior and the actual observed impacts to the ISS USOS. Information on mitigation steps to protect the health of future CHX hydrophilic coatings as well as remediation and recovery of the full heat exchanger will be

  11. Wisconsin Air Cargo Study

    Science.gov (United States)

    2011-04-01

    Air cargo is a key economic lifeline for the communities that have airports. Manufacturers, businesses, hospitals and : other community cornerstone employers depend on air cargo to successfully operate. While there is no doubt that air : cargo repres...

  12. Can a photocatalytic air purifier be used to improve the perceived air quality indoors?

    DEFF Research Database (Denmark)

    Kolarik, Jakub; Wargocki, Pawel

    2010-01-01

    The effect of a photocatalytic air purifier on perceived air quality(PAQ) was examined in rooms polluted by typical sources of indoor pollution.The rooms were ventilated at three different outdoor air supply rates. The air quality was assessed by a sensory panel when the purifier was in operation...... as well as when it was off. Operation of the purifier significantly improved PAQ in the rooms polluted by building materials (used carpet, old linoleum, and old chip-board), and a used ventilation filter as well as a mixture of building materials, used ventilation filter and cathode-ray tube computer...... monitors. The effect cor-responded to approximately doubling the outdoor air supply rate. Operation of the purifier significantly worsened the PAQ in rooms with human bioeffluents, probably due to incomplete oxidation of alcohols which are one of the main pollutants emitted by humans. Present results show...

  13. Results from prototypes of environmental and health alarm devices based on gaseous detectors operating in air in counting mode

    CERN Document Server

    Martinengo, P; Peskov, V; Benaben, P; Charpak, G; Breuil, P

    2011-01-01

    We have developed and successfully tested two prototypes of detectors of dangerous gases based on wire-type counters operating in air in avalanche mode: one is for radon (Rn) detection whereas the other one is for the detection of gases with an ionization potential less than the air components. Due to the operation in pulse counting mode these prototypes have sensitivities comparable to (in the case of the Rn detector) or much higher than (in the case of the detector for low ionization gases) the best commercial devices currently available on the market. We believe that due to their high sensitivity, simplicity and low cost such new detectors will find massive applications. One of them, discussed in this paper, could be the on-line monitoring of Rn for the prediction of earthquakes. (C) 2010 Elsevier B.V. All rights reserved.

  14. 75 FR 22400 - Clean Air Act Operating Permit Program; Petition To Object to Title V Permit for Wheelabrator...

    Science.gov (United States)

    2010-04-28

    ... ENVIROMENTAL PROTECTION AGENCY [FRL-9142-6] Clean Air Act Operating Permit Program; Petition To Object to Title V Permit for Wheelabrator Baltimore, L.P., Baltimore City, MD AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of final action. SUMMARY: Pursuant to section 505(b)(2) of the Clean...

  15. Impact of excess NOx emissions from diesel cars on air quality, public health and eutrophication in Europe

    Science.gov (United States)

    Jonson, J. E.; Borken-Kleefeld, J.; Simpson, D.; Nyíri, A.; Posch, M.; Heyes, C.

    2017-09-01

    Diesel cars have been emitting four to seven times more NOx in on-road driving than in type approval tests. These ‘excess emissions’ are a consequence of deliberate design of the vehicle’s after-treatment system, as investigations during the ‘Dieselgate’ scandal have revealed. Here we calculate health and environmental impacts of these excess NOx emissions in all European countries for the year 2013. We use national emissions reported officially under the UNECE Convention for Long-range Transport of Atmospheric Pollutants and employ the EMEP MSC-W Chemistry Transport Model and the GAINS Integrated Assessment Model to determine atmospheric concentrations and resulting impacts. We compare with impacts from hypothetical emissions where light duty diesel vehicles are assumed to emit only as much as their respective type approval limit value or as little as petrol cars of the same age. Excess NO2 concentrations can also have direct health impacts, but these overlap with the impacts from particulate matter (PM) and are not included here. We estimate that almost 10 000 premature deaths from PM2.5 and ozone in the adult population (age >30 years) can be attributed to the NOx emissions from diesel cars and light commercial vehicles in EU28 plus Norway and Switzerland in 2013. About 50% of these could have been avoided if diesel limits had been achieved also in on-road driving; and had diesel cars emitted as little NOx as petrol cars, 80% of these premature deaths could have been avoided. Ecosystem eutrophication impacts (critical load exceedances) from the same diesel vehicles would also have been reduced at similar rates as for the health effects.

  16. Optimizing the Air Dissolution Parameters in an Unpacked Dissolved Air Flotation System

    Directory of Open Access Journals (Sweden)

    Adam Dassey

    2011-12-01

    Full Text Available Due to the various parameters that influence air solubility and microbubble production in dissolved air flotation (DAF, a multitude of values that cover a large range for these parameters are suggested for field systems. An unpacked saturator and an air quantification unit were designed to specify the effects of power, pressure, temperature, hydraulic retention time, and air flow on the DAF performance. It was determined that a pressure of 621 kPa, hydraulic retention time of 18.2 min, and air flow of 8.5 L/h would be the best controlled parameters for maximum efficiency in this unit. A temperature of 7 °C showed the greatest microbubble production, but temperature control would not be expected in actual application. The maximum microbubble flow from the designed system produced 30 mL of air (±1.5 per L of water under these conditions with immediate startup. The maximum theoretical dissolved air volume of 107 mL (±6 was achieved at a retention time of 2 h and a pressure of 621 kPa. To isolate and have better control over the various DAF operational parameters, the DAF unit was operated without the unsaturated flow stream. This mode of operation led to the formation of large bubbles at peak bubble production rates. In a real-world application, the large bubble formation will be avoided by mixing with raw unsaturated stream and by altering the location of dissolved air output flow.

  17. Preventive maintenance basis: Volume 1 -- Air-operated valves. Final report

    International Nuclear Information System (INIS)

    Worledge, D.; Hinchcliffe, G.

    1997-07-01

    US nuclear plants are implementing preventive maintenance (PM) tasks with little documented basis beyond fundamental vendor information to support the tasks or their intervals. The Preventive Maintenance Basis project provides utilities with the technical basis for PM tasks and task intervals associated with 40 specific components such as valves, electric motors, pumps, and HVAC equipment. This report provides an overview of the PM Basis project and describes use of the PM Basis database. This document provides a program of PM tasks suitable for application to Air Operated Valves (AOV's) in nuclear power plants. The PM tasks that are recommended provide a cost-effective way to intercept the causes and mechanisms that lead to degradation and failure. They can be used, in conjunction with material from other sources, to develop a complete PM program or to improve an existing program. Users of this information will be utility managers, supervisors, craft technicians, and training instructors responsible for developing, optimizing, or fine-tuning PM programs

  18. Does Excessive Pronation Cause Pain?

    DEFF Research Database (Denmark)

    Mølgaard, Carsten Møller; Olesen Gammelgaard, Christian; Nielsen, R. G.

    Excessive pronation could be an inborn abnormality or an acquired foot disorder caused by overuse, inadequate supported shoes or inadequate foot training. When the muscles and ligaments of the foot are insufficient it can cause an excessive pronation of the foot. The current treatment consist...... of antipronation shoes or insoles, which latest was studied by Kulce DG., et al (2007). So far there have been no randomized controlled studies showing methods that the effect of this treatment has not been documented. Therefore the authors can measure the effect of treatments with insoles. Some of the excessive...

  19. Advantages for passengers and cabin crew of operating a Gas-Phase Adsorption air purifier in 11-h simulated flights

    DEFF Research Database (Denmark)

    Strøm-Tejsen, Peter; Zukowska, Daria; Fang, Lei

    2008-01-01

    Experiments were carried out in a 3-row, 21-seat section of a simulated aircraft cabin installed in a climate chamber to evaluate the extent to which passengers’ perception of cabin air quality is affected by the operation of a Gas-Phase Adsorption (GPA) purification unit. A total of 68 subjects......, divided into four groups of 17 subjects took part in simulated 11-hour flights. Each group experienced 4 conditions in balanced order, defined by two outside air supply rates (2.4 and 3.3 L/s per person), with and without the GPA purification unit installed in the recirculated air system. During each...... flight the subjects completed questionnaires five times to provide subjective assessments of air quality, cabin environment, intensity of symptoms, and thermal comfort. Additionally, the subjects’ visual acuity, finger temperature, skin dryness and nasal peak flow were measured three times during each...

  20. Feasibility of a solar-assisted winter air-conditioning system using evaporative air-coolers

    Energy Technology Data Exchange (ETDEWEB)

    El-Awad, Mohamed M. [Mechanical Engineering Department, the University of Khartoum, P.O. Box 321 Khartoum (Sudan)

    2011-07-01

    The paper presents a winter air-conditioning system which is suitable for regions with mildly cold but dry winters. The system modifies the evaporative air-cooler that is commonly used for summer air-conditioning in such regions by adding a heating process after the humidification process. The paper describes a theoretical model that is used to estimate the system's water and energy consumption. It is shown that a 150-LPD solar heater is adequate for air-conditioning a 500 ft3/min (14.4 m3/min) air flow rate for four hours of operation. The maximum air-flow rate that can be heated by a single solar water-heater for four hours of operation is about 900-cfm, unless a solar water heater large than a 250-LPD heater is used. For the 500 ft3/min air flow rate the paper shows that the 150, 200, 250 and 300 LPD solar water-heaters can provide air-conditioning for 4, 6, 8 and 10 hours, respectively, while consuming less energy than the equivalent refrigerated-type air-conditioner.

  1. Towards energy efficient operation of Heating, Ventilation and Air Conditioning systems via advanced supervisory control design

    Science.gov (United States)

    Oswiecinska, A.; Hibbs, J.; Zajic, I.; Burnham, K. J.

    2015-11-01

    This paper presents conceptual control solution for reliable and energy efficient operation of heating, ventilation and air conditioning (HVAC) systems used in large volume building applications, e.g. warehouse facilities or exhibition centres. Advanced two-level scalable control solution, designed to extend capabilities of the existing low-level control strategies via remote internet connection, is presented. The high-level, supervisory controller is based on Model Predictive Control (MPC) architecture, which is the state-of-the-art for indoor climate control systems. The innovative approach benefits from using passive heating and cooling control strategies for reducing the HVAC system operational costs, while ensuring that required environmental conditions are met.

  2. A COMPREHENSIVE CENSUS OF NEARBY INFRARED EXCESS STARS

    Energy Technology Data Exchange (ETDEWEB)

    Cotten, Tara H.; Song, Inseok, E-mail: tara@physast.uga.edu, E-mail: song@physast.uga.edu [Department of Physics and Astronomy, University of Georgia, Athens, GA 30602 (United States)

    2016-07-01

    The conclusion of the Wide-Field Infrared Survey Explorer ( WISE ) mission presents an opportune time to summarize the history of using excess emission in the infrared as a tracer of circumstellar material and exploit all available data for future missions such as the James Webb Space Telescope . We have compiled a catalog of infrared excess stars from peer-reviewed articles and perform an extensive search for new infrared excess stars by cross-correlating the Tycho-2 and all-sky WISE (AllWISE) catalogs. We define a significance of excess in four spectral type divisions and select stars showing greater than either 3 σ or 5 σ significance of excess in the mid- and far-infrared. Through procedures including spectral energy distribution fitting and various image analyses, each potential excess source was rigorously vetted to eliminate false positives. The infrared excess stars from the literature and the new stars found through the Tycho-2 and AllWISE cross-correlation produced nearly 500 “Prime” infrared excess stars, of which 74 are new sources of excess, and >1200 are “Reserved” stars, of which 950 are new sources of excess. The main catalog of infrared excess stars are nearby, bright, and either demonstrate excess in more than one passband or have infrared spectroscopy confirming the infrared excess. This study identifies stars that display a spectral energy distribution suggestive of a secondary or post-protoplanetary generation of dust, and they are ideal targets for future optical and infrared imaging observations. The final catalogs of stars summarize the past work using infrared excess to detect dust disks, and with the most extensive compilation of infrared excess stars (∼1750) to date, we investigate various relationships among stellar and disk parameters.

  3. Inappropriate and Excessive Guilt: Instrument Validation and Developmental Differences in Relation to Depression

    Science.gov (United States)

    Tilghman-Osborne, Carlos; Cole, David A.; Felton, Julia W.

    2012-01-01

    Inappropriate or excessive guilt is listed as a symptom of depression by the American Psychiatric Association ("1994"). Although many measures of guilt have been developed, definitional and operational problems exist, especially in the application of such measures in childhood and adolescence. To address these problems, the current study…

  4. Operations and Maintenance Manual for Full-Scale Bioventing System at FSA-1, Air Force Plant 4, Fort Worth, Texas

    National Research Council Canada - National Science Library

    1996-01-01

    This Operations and Maintenance (O&M) Manual has been created as a guide for monitoring and maintaining the performance of the full-scale bioventing blower system and vent well plumbing at FSA-1 at Air Force Plant 4 (AFP4), Texas...

  5. Air Quality | Air Quality Planning & Standards | US EPA

    Science.gov (United States)

    2016-06-08

    Air pollution comes from many different sources: stationary sources such as factories, power plants, and smelters and smaller sources such as dry cleaners and degreasing operations; mobile sources such as cars, buses, planes, trucks, and trains; and naturally occurring sources such as windblown dust, and volcanic eruptions, all contribute to air pollution.

  6. Does excessive pronation cause pain?

    DEFF Research Database (Denmark)

    Olesen, C G; Nielsen, Rasmus Gottschalk N; Rathleff, Michael Skovdal

    2008-01-01

    Excessive pronation could be an inborn abnormality or an acquired foot disorder caused by overuse, inadequate supported shoes or inadequate foot training. When the muscles and ligaments of the foot are insufficient it can cause an excessive pronation of the foot. The current treatment consist of ...

  7. Air Traffic Management Technology Demonstration-1 Concept of Operations (ATD-1 ConOps), Version 2.0

    Science.gov (United States)

    Baxley, Brian T.; Johnson, William C.; Swenson, Harry N.; Robinson, John E.; Prevot, Tom; Callantine, Todd J.; Scardina, John; Greene, Michael

    2013-01-01

    This document is an update to the operations and procedures envisioned for NASA s Air Traffic Management (ATM) Technology Demonstration #1 (ATD-1). The ATD-1 Concept of Operations (ConOps) integrates three NASA technologies to achieve high throughput, fuel-efficient arrival operations into busy terminal airspace. They are Traffic Management Advisor with Terminal Metering (TMA-TM) for precise time-based schedules to the runway and points within the terminal area, Controller-Managed Spacing (CMS) decision support tools for terminal controllers to better manage aircraft delay using speed control, and Flight deck Interval Management (FIM) avionics and flight crew procedures to conduct airborne spacing operations. The ATD-1 concept provides de-conflicted and efficient operations of multiple arrival streams of aircraft, passing through multiple merge points, from top-of-descent (TOD) to the Final Approach Fix. These arrival streams are Optimized Profile Descents (OPDs) from en route altitude to the runway, using primarily speed control to maintain separation and schedule. The ATD-1 project is currently addressing the challenges of integrating the three technologies, and their implantation into an operational environment. The ATD-1 goals include increasing the throughput of high-density airports, reducing controller workload, increasing efficiency of arrival operations and the frequency of trajectory-based operations, and promoting aircraft ADS-B equipage.

  8. Spatiotemporal and economic analysis of industrial excess heat as a resource for district heating

    DEFF Research Database (Denmark)

    Bühler, Fabian; Petrović, Stefan; Holm, Fridolin Müller

    2018-01-01

    detailed analysis of the most suitable types of industries and the costs is required, allowing a targeted exploitation of this resource. This work extends the spatial and thermodynamic analysis, to account for the temporal match between industrial excess heat and district heating demands, as well...... as the costs for implementation and operation of the systems. This allows the determination of cost-effective district heating potentials, as well as the analysis of different industries and technological requirements. The results show that the temporal mismatch between excess heat and district heating demand...... and lack of demand, reduces the theoretical substitution potential by almost 30%. If heat storages are introduced, the total potential is reduced by only 10%. A majority of the excess heat can be utilised at socio-economic heating costs lower than the average Danish district heating price and the cost...

  9. Experimental analysis of an air-to-air heat recovery unit for balanced ventilation systems in residential buildings

    International Nuclear Information System (INIS)

    Fernandez-Seara, Jose; Diz, Ruben; Uhia, Francisco J.; Dopazo, Alberto; Ferro, Jose M.

    2011-01-01

    This paper deals with the experimental analysis of an air-to-air heat recovery unit equipped with a sensible polymer plate heat exchanger (PHE) for balanced ventilation systems in residential buildings. The PHE is arranged in parallel triangular ducts. An experimental facility was designed to reproduce the typical outdoor and exhaust air conditions with regard to temperature and humidity. The unit was tested under balanced operation conditions, as commonly used in practice. A set of tests was conducted under the reference operating conditions to evaluate the PHE performance. Afterwards, an experimental parametric analysis was conducted to investigate the influence of changing the operating conditions on the PHE performance. Experiments were carried out varying the inlet fresh air temperature, the exhaust air relative humidity and the air flow rate. The experimental results are shown and discussed in this paper.

  10. A portable system powered with hydrogen and one single air-breathing PEM fuel cell

    International Nuclear Information System (INIS)

    Fernández-Moreno, J.; Guelbenzu, G.; Martín, A.J.; Folgado, M.A.; Ferreira-Aparicio, P.; Chaparro, A.M.

    2013-01-01

    Highlights: • A portable system based on hydrogen and single air breathing PEM fuel cell. • Control electronics designed for low single cell voltage (0.5–0.8 V). • Forced air convection and anode purging required to help water management. • Application consisting of a propeller able to display a luminous message. • Up to 20 h autonomy with continuous 1.1 W consumption, using 1 g H 2 . - Abstract: A portable system for power generation based on hydrogen and a single proton exchange membrane fuel cell (PEMFC) has been built and operated. The fuel cell is fed in the anode with hydrogen stored in a metal hydrides cartridge, and in the cathode with oxygen from quiescent ambient air (‘air breathing’). The control electronics of the system performs DC–DC conversion from the low voltage (0.5–0.8 V) and high current output (200–300 mA cm −2 ) of the single fuel cell, up to 3.3 V to power an electronic application. System components assist fuel cell operation, including an electronic valve for anode purging, a fan in front of the open cathode, two supercapacitors for auxiliary power requirements, four LED lights, and a display screen. The influence of the system components on fuel cell behaviour is analyzed. The cathode fan and anodic purging help excess water removal from the electrodes leading to steadier cell response at the expense of extra power consumption. The power system is able to provide above 1 W DC electricity to an external application during 20 h using 1 g of H 2 . An application consisting of a propeller able to display a luminous message is chosen to test system. It is shown that one single air breathing PEM fuel cell powered with hydrogen may provide high energy density and autonomy for portable applications

  11. Compressed-air power tools in orthopaedic surgery: exhaust air is a potential source of contamination.

    Science.gov (United States)

    Sagi, H C; DiPasquale, Thomas; Sanders, Roy; Herscovici, Dolfi

    2002-01-01

    To determine if the exhaust from surgical compressed-air power tools contains bacteria and if the exhaust leads to contamination of sterile surfaces. Bacteriologic study of orthopaedic power tools. Level I trauma center operative theater. None. Part I. Exhaust from two sterile compact air drills was sampled directly at the exhaust port. Part II. Exhaust from the drills was directed at sterile agar plates from varying distances. The agar plates represented sterile surfaces within the operative field. Part III. Control cultures. A battery-powered drill was operated over open agar plates in similar fashion as the compressed-air drills. Agar plates left open in the operative theater served as controls to rule out atmospheric contamination. Random cultures were taken from agar plates, gloves, drills, and hoses. Incidence of positive cultures. In Part I, all filters from both compressed-air drill exhausts were culture negative ( = 0.008). In Part II, the incidence of positive cultures for air drills number one and number two was 73% and 82%, respectively. The most commonly encountered organisms were, coagulase-negative Staphylococcus, and Micrococcus species. All control cultures from agar plates, battery-powered drill, gloves, and hoses were negative ( compressed-air power tools in orthopaedic surgery may contribute to the dissemination of bacteria onto the surgical field. We do not recommend the use of compressed-air power tools that do not have a contained exhaust.

  12. Air Quality Facilities

    Data.gov (United States)

    Iowa State University GIS Support and Research Facility — Facilities with operating permits for Title V of the Federal Clean Air Act, as well as facilities required to submit an air emissions inventory, and other facilities...

  13. 14 CFR 129.19 - Air traffic rules and procedures.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Air traffic rules and procedures. 129.19 Section 129.19 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR CARRIERS AND OPERATORS FOR COMPENSATION OR HIRE: CERTIFICATION AND OPERATIONS OPERATIONS: FOREIGN AIR CARRIERS AND FOREIGN OPERATORS OF ...

  14. Hygiene guideline for the planning, installation, and operation of ventilation and air-conditioning systems in health-care settings – Guideline of the German Society for Hospital Hygiene (DGKH

    Directory of Open Access Journals (Sweden)

    Külpmann, Rüdiger

    2016-02-01

    Full Text Available Since the publication of the first “Hospital Hygiene Guideline for the implementation and operation of air conditioning systems (HVAC systems in hospitals” ( in 2002, it was necessary due to the increase in knowledge, new regulations, improved air-conditioning systems and advanced test methods to revise the guideline. Based on the description of the basic features of ventilation concepts, its hygienic test and the usage-based requirements for ventilation, the DGKH section “Ventilation and air conditioning technology” attempts to provide answers for the major air quality issues in the planning, design and the hygienically safe operation of HVAC systems in rooms of health care.

  15. 76 FR 53452 - Clean Air Act Operating Permit Program; Response to Petition To Reopen the 2001 Title V Permit...

    Science.gov (United States)

    2011-08-26

    ... ENVIROMENTAL PROTECTION AGENCY [FRL-9457-3 ] Clean Air Act Operating Permit Program; Response to Petition To Reopen the 2001 Title V Permit for Reliant Portland Generating Station, Upper Mount Bethel Township, Northampton County, PA AGENCY: Environmental Protection Agency (EPA). ACTION: Notice of action...

  16. Potential ozone impacts of excess NO2 emissions from diesel particulate filters for on- and off-road diesel engines.

    Science.gov (United States)

    Bar-llan, Amnon; Johnson, Jeremiah R; Denbleyker, Allison; Chan, Lit-Mian; Yarwood, Gregory; Hitchcock, David; Pinto, Joseph P

    2010-08-01

    This study considers potential impacts of increased use of diesel oxidation catalysts (DOCs) and catalyzed diesel particulate filters (DPFs) on ozone formation in the Dallas/ Fort Worth (DFW) area. There is concern that excess nitrogen dioxide (NO2) emissions from vehicles equipped with these devices could increase ambient ozone levels. The approach involved developing two scenarios for use of these devices, quantifying excess NO2 emissions in each scenario, and using a photochemical model to estimate the resulting ozone changes. In the "maximum penetration" scenario, DOC/DPF devices in a 2009 fleet of heavy-duty on-road trucks, school buses, and construction equipment were significantly increased by accelerating turnover of these vehicles and equipment to models that would require DOCs/DPFs. In the "realistic" scenario, current fractional usage of these devices was assessed for 2009. For both scenarios, excess NO2 emissions from DOCs/DPFs were estimated using U.S. Environmental Protection Agency's MOBILE6 and NONROAD emissions inventory modeling tools. The emissions analyses were used to adjust the DFW photochemical modeling emissions inventories and the Comprehensive Air Quality Model with extensions air quality model was rerun for the DFW area to determine the impact of these two scenarios on ozone formation. The maximum penetration scenario, which showed an overall reduction in oxides of nitrogen (NO(x)) because of the accelerated turnover of equipment to cleaner models, resulted in a net decrease in daily maximum 8-hr ozone of 4-5 parts per billion (ppb) despite the increase in NO2 emissions. The realistic scenario resulted in a small increase in daily maximum 8-hr ozone of less than 1 ppb for the DFW area. It was concluded that the excess NO2 emissions from DOC/DPF devices result in very small ozone impacts, particularly for the realistic scenario, in the DFW area. There are noticeable decreases in ozone for the maximum penetration scenario because NO

  17. Raising the Reliability, Efficiency, and Ecological Safety of Operation of the BKZ-210-140F Boiler Transferred to Stage Firing of Kuznetsk Coal in a U-Shape Flame

    International Nuclear Information System (INIS)

    Vagner, A. A.

    2004-01-01

    The BKZ-210-140F boiler of the West-Siberian Cogeneration Plant was equipped initially with four uniflow tangentially oriented burners and tertiary air nozzles. In order to raise the efficiency of operation and lower harmful emissions the boiler was reconstructed. U-shape aerodynamics was organized in the furnace by mounting 8 burners, 8 secondary air nozzles, and 8 tertiary air nozzles on the front and rear walls of the furnace. The reconstruction ensured higher stability of ignition of pulverized coal without flame division and rated temperatures of the superheater metal, lowered the optimum excess air factor at the outlet from the superheater to 1.2 - 1.25, decreased the concentration of nitrogen oxides in the combustion products to 360 - 380 mg/m 3 , and increased the gross efficiency of the boiler to 91.5 - 91.7%

  18. Operational Law Handbook,2007

    National Research Council Canada - National Science Library

    2007-01-01

    ... & SOFAs, legal assistance, combating terrorism, domestic operations, noncombatant evacuation operations, special operations, civil affairs, air, sea, and space law, detainee operations, reserve...

  19. The Air Warrior's Value of National Security Space

    National Research Council Canada - National Science Library

    Loftis, J

    2003-01-01

    ...) approach was used to elicit values from air combat experts with operational experience. An initial Gold Standard value model was constructed and validated by air combat experts with recent experience in joint air operations...

  20. Operation Thursday: Birth of the Air Commandos

    National Research Council Canada - National Science Library

    Mason, Herbert A., Jr; Bergeron, Randy G; Renfrow, James A., Jr

    1994-01-01

    .... On March 5-6, 1944, the Allies conducted an air invasion of Burma in an attempt to push back the Japanese in the China-Burma-India Theater and reestablish the land route between India and China. U.S...

  1. Member for conducting excess heat away from heat sources

    International Nuclear Information System (INIS)

    Cooke-Yarborough, E.H.

    1975-01-01

    Should a radioisotope-powered engine (e.g., a Stirling cycle engine for generating electricity) stop working for any reason, the radioisotope heat source will continue to generate heat. This will result in a rise in temperature which may cause overheating of and possible damage to the engine as well as to the heat source itself. The invention provides a support/location member for conducting excess heat from the heat source and which, in normal operation of the engine, will impede the conduction of heat away from the heat source and so reduce thermal losses. The member is of elongated form and comprises a stack of heat-conductive slugs disposed in a tube and in interspaced relationship along the axis of the tube. The tube supports the slugs in axial alignment. Means are provided for attaching an end one of the slugs to the heat source and means operable on overheating of said end one of the slugs are also provided whereby the slugs are able to move into heat-conducting contact with each other so as to conduct the excess heat away from said heat source. The slugs may be brazed to the tube whereby progressive overheating of the slugs along the stack results in an overheated slug being freed from attachment to the tube so as to allow the overheated slug to move along the stack and engage the next slug in line in heat-conducting contact. (U.S.)

  2. Air filtration in HVAC systems

    CERN Document Server

    Ginestet, Alain; Tronville, Paolo; Hyttinen, Marko

    2010-01-01

    Air filtration Guidebook will help the designer and user to understand the background and criteria for air filtration, how to select air filters and avoid problems associated with hygienic and other conditions at operation of air filters. The selection of air filters is based on external conditions such as levels of existing pollutants, indoor air quality and energy efficiency requirements.

  3. The Continued Need for USAF Light Attack post OEF/OIF: A Survey of West African Infrastructure to Support Tactical Air Operations

    Science.gov (United States)

    2013-04-01

    Mauritania’s two main airfields, at Nouakchott and Atar , have 9,800 foot runways that A-10s could operate from. In addition to those airfields...running road passes through Atar , Zouerat and Bir Moghrein on the way to Algeria. Without the use of the bases at Zouerat and Bir Moghrein the highway...runs almost 400 miles beyond extended duration air support from Atar . With the legacy platforms currently available, the USAF could provide air

  4. Evaluation of Excess Heat Utilization in District Heating Systems by Implementing Levelized Cost of Excess Heat

    Directory of Open Access Journals (Sweden)

    Borna Doračić

    2018-03-01

    Full Text Available District heating plays a key role in achieving high primary energy savings and the reduction of the overall environmental impact of the energy sector. This was recently recognized by the European Commission, which emphasizes the importance of these systems, especially when integrated with renewable energy sources, like solar, biomass, geothermal, etc. On the other hand, high amounts of heat are currently being wasted in the industry sector, which causes low energy efficiency of these processes. This excess heat can be utilized and transported to the final customer by a distribution network. The main goal of this research was to calculate the potential for excess heat utilization in district heating systems by implementing the levelized cost of excess heat method. Additionally, this paper proves the economic and environmental benefits of switching from individual heating solutions to a district heating system. This was done by using the QGIS software. The variation of different relevant parameters was taken into account in the sensitivity analysis. Therefore, the final result was the determination of the maximum potential distance of the excess heat source from the demand, for different available heat supplies, costs of pipes, and excess heat prices.

  5. Evaluation of operational on-line-coupled regional air quality models over Europe and North America in the context of AQMEII phase 2. Part I: Ozone

    NARCIS (Netherlands)

    Im, U.; Bianconi, R.; Solazzo, E.; Kioutsioukis, I.; Badia, A.; Balzarini, A.; Baró, R.; Bellasio, R.; Brunner, D.; Chemel, C.; Curci, G.; Flemming, J.; Forkel, R.; Giordano, L.; Jiménez-Guerrero, P.; Hirtl, M.; Hodzic, A.; Honzak, L.; Jorba, O.; Knote, C.; Kuenen, J.J.P.; Makar, P.A.; Manders-Groot, A.; Neal, L.; Pérez, J.L.; Pirovano, G.; Pouliot, G.; San Jose, R.; Savage, N.; Schroder, W.; Sokhi, R.S.; Syrakov, D.; Torian, A.; Tuccella, P.; Werhahn, J.; Wolke, R.; Yahya, K.; Zabkar, R.; Zhang, Y.; Zhang, J.; Hogrefe, C.; Galmarini, S.

    2015-01-01

    The second phase of the Air Quality Model Evaluation International Initiative (AQMEII) brought together sixteen modeling groups from Europe and North America, running eight operational online-coupled air quality models over Europe and North America on common emissions and boundary conditions. With

  6. Study on the Optimizing Operation of Exhaust Air Heat Recovery and Solar Energy Combined Thermal Compensation System for Ground-Coupled Heat Pump

    Directory of Open Access Journals (Sweden)

    Kuan Wang

    2017-01-01

    Full Text Available This study proposed an exhaust air heat recovery and solar energy combined thermal compensation system (ESTC for ground-coupled heat pumps. Based on the prediction of the next day’s exhaust air temperature and solar irradiance, an optimized thermal compensation (OTC method was developed in this study as well, in which the exhaust air heat recovery compensator and solar energy compensator in the ESTC system run at high efficiency throughout various times of day. Moreover, a modified solar term similar days group (STSDG method was proposed to improve the accuracy of solar irradiance prediction in hazy weather. This modified STSDG method was based on air quality forecast and AQI (air quality index correction factors. Through analyzing the operating parameters and the simulation results of a case study, the ESTC system proved to have good performance and high efficiency in eliminating the heat imbalance by using the OTC method. The thermal compensation quantity per unit energy consumption (TEC of ESTC under the proposed method was 1.25 times as high as that under the traditional operation method. The modified STSDG method also exhibited high accuracy. For the accumulated solar irradiance of the four highest daily radiation hours, the monthly mean absolute percentage error (MAPE between the predicted values and the measured values was 6.35%.

  7. Excessive masturbation after epilepsy surgery.

    Science.gov (United States)

    Ozmen, Mine; Erdogan, Ayten; Duvenci, Sirin; Ozyurt, Emin; Ozkara, Cigdem

    2004-02-01

    Sexual behavior changes as well as depression, anxiety, and organic mood/personality disorders have been reported in temporal lobe epilepsy (TLE) patients before and after epilepsy surgery. The authors describe a 14-year-old girl with symptoms of excessive masturbation in inappropriate places, social withdrawal, irritability, aggressive behavior, and crying spells after selective amygdalohippocampectomy for medically intractable TLE with hippocampal sclerosis. Since the family members felt extremely embarrassed, they were upset and angry with the patient which, in turn, increased her depressive symptoms. Both her excessive masturbation behavior and depressive symptoms remitted within 2 months of psychoeducative intervention and treatment with citalopram 20mg/day. Excessive masturbation is proposed to be related to the psychosocial changes due to seizure-free status after surgery as well as other possible mechanisms such as Kluver-Bucy syndrome features and neurophysiologic changes associated with the cessation of epileptic discharges. This case demonstrates that psychiatric problems and sexual changes encountered after epilepsy surgery are possibly multifactorial and in adolescence hypersexuality may be manifested as excessive masturbation behavior.

  8. Management of Excessive Weight Loss Following Laparoscopic Roux-en-Y Gastric Bypass: Clinical Algorithm and Surgical Techniques.

    Science.gov (United States)

    Akusoba, Ikemefuna; Birriel, T Javier; El Chaar, Maher

    2016-01-01

    There are no clinical guidelines or published studies addressing excessive weight loss and protein calorie malnutrition following a standard Roux-en-Y gastric bypass (RYGB) to guide nutritional management and treatment strategies. This study demonstrates the presentation, clinical algorithm, surgical technique, and outcomes of patients afflicted and successfully treated with excessive weight loss following a standard RYGB. Three patients were successfully reversed to normal anatomy after evaluation, management, and treatment by multidisciplinary team. Lowest BMI (kg/m(2)) was 18.9, 17.9, and 14.2, respectively. Twelve-month post-operative BMI (kg/m(2)) was 28.9, 22.8, and 26.1, respectively. Lowest weight (lbs) was 117, 128, and 79, respectively. Twelve-month post-operative weight (lbs) was 179, 161, and 145, respectively. Pre-reversal gastrostomy tube was inserted into the remnant stomach to demonstrate weight gain and improve nutritional status prior to reversal to original anatomy. We propose a practical clinical algorithm for the work-up and management of patients with excessive weight loss and protein calorie malnutrition after standard RYGB including reversal to normal anatomy.

  9. Excess cash holdings and shareholder value

    OpenAIRE

    Lee, Edward; Powell, Ronan

    2011-01-01

    We examine the determinants of corporate cash holdings in Australia and the impact on shareholder wealth of holding excess cash. Our results show that a trade-off model best explains the level of a firm’s cash holdings in Australia. We find that 'transitory' excess cash firms earn significantly higher risk-adjusted returns compared to 'persistent' excess cash firms, suggesting that the market penalises firms that hoard cash. The marginal value of cash also declines with larger cash balances, ...

  10. Combined analysis of job and task benzene air exposures among workers at four US refinery operations.

    Science.gov (United States)

    Burns, Amanda; Shin, Jennifer Mi; Unice, Ken M; Gaffney, Shannon H; Kreider, Marisa L; Gelatt, Richard H; Panko, Julie M

    2017-03-01

    Workplace air samples analyzed for benzene at four US refineries from 1976 to 2007 were pooled into a single dataset to characterize similarities and differences between job titles, tasks and refineries, and to provide a robust dataset for exposure reconstruction. Approximately 12,000 non-task (>180 min) personal samples associated with 50 job titles and 4000 task (job titles and task codes across all four refineries, and (5) our analysis of variance (ANOVA) of the distribution of benzene air concentrations for select jobs/tasks across all four refineries. The jobs and tasks most frequently sampled included those with highest potential contact with refinery product streams containing benzene, which reflected the targeted sampling approach utilized by the facility industrial hygienists. Task and non-task data were analyzed to identify and account for significant differences within job-area, task-job, and task-area categories. This analysis demonstrated that in general, areas with benzene containing process streams were associated with greater benzene air concentrations compared to areas with process streams containing little to no benzene. For several job titles and tasks analyzed, there was a statistically significant decrease in benzene air concentration after 1990. This study provides a job and task-focused analysis of occupational exposure to benzene during refinery operations, and it should be useful for reconstructing refinery workers' exposures to benzene over the past 30 years.

  11. Antidepressant induced excessive yawning and indifference

    Directory of Open Access Journals (Sweden)

    Bruno Palazzo Nazar

    2015-03-01

    Full Text Available Introduction Antidepressant induced excessive yawning has been described as a possible side effect of pharmacotherapy. A syndrome of indifference has also been described as another possible side effect. The frequency of those phenomena and their physiopathology are unknown. They are both considered benign and reversible after antidepressant discontinuation but severe cases with complications as temporomandibular lesions, have been described. Methods We report two unprecedented cases in which excessive yawning and indifference occurred simultaneously as side effects of antidepressant therapy, discussing possible physiopathological mechanisms for this co-occurrence. Case 1: A male patient presented excessive yawning (approximately 80/day and apathy after venlafaxine XR treatment. Symptoms reduced after a switch to escitalopram, with a reduction to 50 yawns/day. Case 2: A female patient presented excessive yawning (approximately 25/day and inability to react to environmental stressors with desvenlafaxine. Conclusion Induction of indifference and excessive yawning may be modulated by serotonergic and noradrenergic mechanisms. One proposal to unify these side effects would be enhancement of serotonin in midbrain, especially paraventricular and raphe nucleus.

  12. Use of preventive measures for air travel-related venous thrombosis in professionals who attend medical conferences

    NARCIS (Netherlands)

    Kuipers, S.; Cannegieter, S. C.; Middeldorp, S.; Rosendaal, F. R.; Büller, H. R.

    2006-01-01

    BACKGROUND: Lack of guidelines for prevention of air travel-related venous thrombosis may lead to excessive use of potentially dangerous precautions. OBJECTIVES: To assess the use of preventive measures for air travel-related thrombosis in professionals employed in the field of thrombosis and

  13. [Working ability between air and trimix breathing gas under 8 ATA air condition].

    Science.gov (United States)

    Shibayama, M; Kosugi, S; Mohri, M; Yamamura, I; Oda, S; Kimura, A; Takeuchi, J; Mano, Y

    1990-04-01

    Pneumatic caisson work in Japan has come into operation since 1924. Afterward, this technique of compressed air work has been widely utilized in the construction of foundation basements, shafts of the bottom tunnel shields for subway and so forth. While using this technique of compressed air work means that workers have to be exposed to hyperbaric environment, this technique has risks of not only decompression sickness (DCS) but also toxicity of poisonous gas and/or oxygen deficiency. However, this technique is independent of city construction work and the operation of compressed air work higher than 5ATA (4.0 kg/cm2G) is actually been planning recently. Accordingly unmanned caisson work is considered as a better technique for such higher pressurized work, even though workers must enter into hyperbaric working fields for maintenance or repair of unmanned operated machinery and materials. This research is to establish the safe work under hyperbaric air environment at 8ATA.

  14. AIR INGRESS ANALYSIS: COMPUTATIONAL FLUID DYNAMIC MODELS

    Energy Technology Data Exchange (ETDEWEB)

    Chang H. Oh; Eung S. Kim; Richard Schultz; Hans Gougar; David Petti; Hyung S. Kang

    2010-08-01

    The Idaho National Laboratory (INL), under the auspices of the U.S. Department of Energy, is performing research and development that focuses on key phenomena important during potential scenarios that may occur in very high temperature reactors (VHTRs). Phenomena Identification and Ranking Studies to date have ranked an air ingress event, following on the heels of a VHTR depressurization, as important with regard to core safety. Consequently, the development of advanced air ingress-related models and verification and validation data are a very high priority. Following a loss of coolant and system depressurization incident, air will enter the core of the High Temperature Gas Cooled Reactor through the break, possibly causing oxidation of the in-the core and reflector graphite structure. Simple core and plant models indicate that, under certain circumstances, the oxidation may proceed at an elevated rate with additional heat generated from the oxidation reaction itself. Under postulated conditions of fluid flow and temperature, excessive degradation of the lower plenum graphite can lead to a loss of structural support. Excessive oxidation of core graphite can also lead to the release of fission products into the confinement, which could be detrimental to a reactor safety. Computational fluid dynamic model developed in this study will improve our understanding of this phenomenon. This paper presents two-dimensional and three-dimensional CFD results for the quantitative assessment of the air ingress phenomena. A portion of results of the density-driven stratified flow in the inlet pipe will be compared with results of the experimental results.

  15. Project CHECO Southeast Asia Report. Air Operations in Northern Laos, 1 November 1970 - 1 April 1971

    Science.gov (United States)

    1971-05-03

    to be of sufficient size and scope to warrant a significant increase in the daily tacair sortie rate provided by Seventh Air Force. The execution of...weather, however, delayed the operation. A last-minute change of HLZs was made by CAS, but weather and faulty execution precluded proper zone...Artillery Airborne Battlefield Command and Control Center Attacks by Fire Jtq 1£4+, .. Auto Defense du Choc . Technically an obsolete tenn now. Refers

  16. Report on the Audit of the Acquisition of the Tactical Air Operations Center/Modular Control Equipment

    Science.gov (United States)

    1991-06-06

    This is our final report on the Audit of the Acquisition of the Tactical Air Operations Center/Modular Control Equipment (TAOC/MCE) for your...matters of concern that could affect the acquisition of the TAOC/MCE. We performed the audit from March through December 1990. The audit objective was...controls related to the audit objectives. The audit was made in accordance with the Inspector General’s critical program management element approach

  17. 26 CFR 54.4981A-1T - Tax on excess distributions and excess accumulations (temporary).

    Science.gov (United States)

    2010-04-01

    ... Revenue Code of 1986, as added by section 1133 of the Tax Reform Act of 1986 (Pub. L. 99-514) (TRA '86...) Determine the value of the individual's adjusted account balance on the next valuation date by adding (or... 26 Internal Revenue 17 2010-04-01 2010-04-01 false Tax on excess distributions and excess...

  18. Efficiency of a pilot-scale integrated sludge thickening and digestion reactor in treating low-organic excess sludge.

    Science.gov (United States)

    He, Qiang; Li, Jiang; Liu, Hongxia; Tang, Chuandong; de Koning, Jaap; Spanjers, Henri

    2012-06-01

    The sludge production from medium- and small-scale wastewater treatment plants in the Three Gorges Reservoir Region is low and non-stable; especially, the organic content in this sludge is low (near 40% of VS/TS). An integrated thickening and digestion (ISTD) reactor was developed to treat this low-organic excess sludge. After a flow test and start-up experiment of the reactor, a running experiment was used to investigate the excess sludge treatment efficiency under five different excess sludge inflows: 200, 300, 400, 500 and 400 L/d (a mixture of excess sludge and primary sludge in a volume ratio of 9:1). This trial was carried out in the wastewater treatment plant in Chongqing, which covers 80% of the Three Gorges Reservoir Region, under the following conditions: (1) sludge was heated to 38-40 degrees C using an electrical heater to maintain anaerobic mesophilic digestion; (2) the biogas produced was recirculated to mix raw sludge with anaerobic sludge in the reactor under the flow rate of 12.5 L/min. There were three main results. Firstly, the flow pattern of the inner reactor was almost completely mixed under the air flow of 12.0 L/min using clear water. Secondly, under all the different sludge inflows, the water content in the outlet sludge was below 93%. Thirdly, the organic content in the outlet sludge was decreased from 37% to 30% and from 24% to 20%, whose removal ratio was in relation to the organic content of the inlet sludge. The excess sludge treatment capacity of the ISTD reactor was according to the organic content in the excess sludge.

  19. Validation and Verification of Operational Land Analysis Activities at the Air Force Weather Agency

    Science.gov (United States)

    Shaw, Michael; Kumar, Sujay V.; Peters-Lidard, Christa D.; Cetola, Jeffrey

    2012-01-01

    The NASA developed Land Information System (LIS) is the Air Force Weather Agency's (AFWA) operational Land Data Assimilation System (LDAS) combining real time precipitation observations and analyses, global forecast model data, vegetation, terrain, and soil parameters with the community Noah land surface model, along with other hydrology module options, to generate profile analyses of global soil moisture, soil temperature, and other important land surface characteristics. (1) A range of satellite data products and surface observations used to generate the land analysis products (2) Global, 1/4 deg spatial resolution (3) Model analysis generated at 3 hours. AFWA recognizes the importance of operational benchmarking and uncertainty characterization for land surface modeling and is developing standard methods, software, and metrics to verify and/or validate LIS output products. To facilitate this and other needs for land analysis activities at AFWA, the Model Evaluation Toolkit (MET) -- a joint product of the National Center for Atmospheric Research Developmental Testbed Center (NCAR DTC), AFWA, and the user community -- and the Land surface Verification Toolkit (LVT), developed at the Goddard Space Flight Center (GSFC), have been adapted to operational benchmarking needs of AFWA's land characterization activities.

  20. Deployable Engine Air Brake

    Science.gov (United States)

    2014-01-01

    On approach, next-generation aircraft are likely to have airframe noise levels that are comparable to or in excess of engine noise. ATA Engineering, Inc. (ATA) is developing a novel quiet engine air brake (EAB), a device that generates "equivalent drag" within the engine through stream thrust reduction by creating a swirling outflow in the turbofan exhaust nozzle. Two Phase II projects were conducted to mature this technology: (1) a concept development program (CDP) and (2) a system development program (SDP).

  1. Comparison of desiccant air conditioning systems with different indirect evaporative air coolers

    International Nuclear Information System (INIS)

    Pandelidis, Demis; Anisimov, Sergey; Worek, William M.; Drąg, Paweł

    2016-01-01

    Highlights: • A numerical study of desiccant air conditioning systems is presented. • The ε-NTU model is used for the analysis. • Different arrangements of the desiccant systems were compared. • The systems were compared under different operating conditions. - Abstract: This paper presents a numerical analysis of three desiccant air-conditioning systems equipped with different indirect evaporative air coolers: (1) the cross-flow Maisotsenko cycle heat and mass exchanger (HMX), (2) the regenerative counter-flow Maisotsenko cycle heat and mass exchanger and (3) the standard cross-flow evaporative air cooler. To analyze the desiccant wheel and the indirect evaporative air coolers, the modified ε-NTU-model was used. The simulations were performed under assumption that the desiccant wheel is regenerated with air heated to relatively low temperature values (50–60 °C), which can be produced with solar panels in typical moderate climatic conditions. It was established that the main advantage of the presented solutions is that they can provide comfort conditions even with less effective dehumidification. The different systems were compared under variable selected operational factors (i.e. inlet air temperature, humidity and regeneration air temperature). The analysis allowed establishing the advantages and disadvantages of presented solutions and allowed estimating their application potential.

  2. THE DEPENDENCE OF HEAT CONSUMPTION ON THE DYNAMICS OF EXTERNAL AIR TEMPERATURE DURING COLD SNAP PERIODS

    Directory of Open Access Journals (Sweden)

    Rymarov Andrey Georgievich

    2014-09-01

    Full Text Available The dynamics of outdoor temperature variations during the cold period of the year influences the operation of the systems providing the required microclimate in the premises, which may be subject to automation systems that affects the IQ of a building, it is important to note that in the last decade there has been a growth in the participation of intelligent technologies in the formation of a microclimate of buildings. Studying the microclimate quality in terms of energy consumption of the premises and the building considers climate variability and outdoor air pollution, which is connected with the economic aspects of energy efficiency and productivity, and health of workers, as a short-term temperature fall in the premises has harmful consequences. Low outdoor temperatures dry the air in the premises that requires accounting for climate control equipment and, if necessary, the personal account of its work. Excess heat in the premises, including office equipment, corrects the temperature conditions, which reduces the adverse effect of cold snap.

  3. A preliminary study on the optimal configuration and operating range of a “microgrid scale” air liquefaction plant for Liquid Air Energy Storage

    International Nuclear Information System (INIS)

    Borri, E.; Tafone, A.; Romagnoli, A.; Comodi, G.

    2017-01-01

    Highlights: • A liquefaction cycle for a microgrid scale Liquid Air Energy Storage is proposed. • Different liquefaction cycles are compared by means of parametric analysis. • The optimal configuration proposed is a Kapitza cycle with two stage compression. • The specific consumption of the optimal configuration is around 700 kW h/t. • Specific consumption reduces to 532 kW h/t if a pressurized phase separator is used. - Abstract: Liquid Air Energy Storage systems represent a sustainable solution to store energy. Although a lot of interest is dedicated to large scale systems (up to 300 tons per day), a small-scale Liquid Air Energy Storage can be used as energy storage as part of a microgrid and/or an energy distribution network. However, when scaling down the size of the system, the round trip efficiency decreases due to the low performance of the liquefaction process. In this paper a preliminary study on the optimal configuration for a microgrid scale liquefaction cycle (10 tons per 12 h) for a Liquid Air Energy Storage application is proposed in order to minimize the specific consumption. The Linde, Claude and Kapitza cycles are modelled and compared by means of a parametric analysis carried out with the software Aspen HYSYS. The results show that the two stages compression Kapitza cycle operating at 40 bar represents an optimal solution in terms of performance and cycle configuration resulting in a specific consumption of about 700 kW h/t. The analysis also shows that the implementation of a pressurized phase separator leads to a reduction of the specific consumption as high as 21% (≈550 kW h/t).

  4. Pulsed operation of high-power light emitting diodes for imaging flow velocimetry

    International Nuclear Information System (INIS)

    Willert, C; Klinner, J; Moessner, S; Stasicki, B

    2010-01-01

    High-powered light emitting diodes (LED) are investigated for possible uses as light sources in flow diagnostics, in particular, as an alternative to laser-based illumination in particle imaging flow velocimetry in side-scatter imaging arrangements. Recent developments in solid state illumination resulted in mass-produced LEDs that provide average radiant power in excess of 10 W. By operating these LEDs with short duration, pulsed currents that are considerably beyond their continuous current damage threshold, light pulses can be generated that are sufficient to illuminate and image micron-sized particles in flow velocimetry. Time-resolved PIV measurements in water at a framing rate of 2kHz are presented. The feasibility of LED-based PIV measurements in air is also demonstrated

  5. Physical activity and exercise dependence during inpatient treatment of longstanding eating disorders: an exploratory study of excessive and non-excessive exercisers.

    Science.gov (United States)

    Bratland-Sanda, Solfrid; Sundgot-Borgen, Jorunn; Rø, Øyvind; Rosenvinge, Jan H; Hoffart, Asle; Martinsen, Egil W

    2010-04-01

    To describe changes in physical activity (PA) and exercise dependence score during treatment of eating disorders (ED), and to explore correlations among changes in PA, exercise motivation, exercise dependence score and ED psychopathology in excessive and non-excessive exercisers. Thirty-eight adult females receiving inpatient treatment for anorexia nervosa, bulimia nervosa or ED not otherwise specified participated in this prospective study. Assessments included accelerometer assessed PA, Exercise Dependence Scale, Reasons for Exercise Inventory, ED Examination, and ED Inventory. Amount of PA was significantly reduced in non-excessive exercisers during treatment, in excessive exercisers there was a trend towards reduced amount of PA from admission to discharge. In excessive exercisers, reduced ED psychopathology was correlated with reduction in exercise dependence score and perceived importance of exercise to regulate negative affects, but not with importance of exercise for weight/appearance. These associations were not found in non-excessive exercisers. Excessive exercise is an important issue in longstanding ED, and the excessive exercising patients need help to develop alternative strategies to regulate negative affects.

  6. Indoor air quality investigation at air-conditioned and non-air-conditioned markets in Hong Kong

    International Nuclear Information System (INIS)

    Guo, H.; Lee, S.C.; Chan, L.Y.

    2004-01-01

    To characterize indoor air quality at the markets in Hong Kong, three non-air-conditioned and two air-conditioned markets were selected for this study. The indoor air pollutants measured included PM 10 (particulate matters with aerodynamic diameter less than 10 μm), total bacteria count (TBC), carbon monoxide (CO), nitric oxide (NO), nitrogen dioxide (NO 2 ) and sulfur dioxide (SO 2 ). The indoor and outdoor concentrations of these target air pollutants at these markets were measured and compared. The effects of air conditioning, temperature/relative humidity variation and different stalls on the indoor air quality were also investigated. The results indicated that all of the average indoor concentrations of PM 10 , TBC, CO and NO 2 at the markets were below the Hong Kong Indoor Air Quality Objectives (HKIAQO) standards with a few exceptions for PM 10 and TBC. The elevated PM 10 concentrations at Hung Hom, Ngau Tau Kok and Wan Chai markets were probably due to the air filtration of outdoor airborne particulates emitted from vehicular exhaust, whereas high concentrations of airborne bacteria at Sai Ying Pun and Tin Shing markets were linked to the use of air conditioning. Correlation analysis demonstrated that indoor bacteria concentrations were correlated with temperature and relative humidity. The operation of air conditioning did not significantly reduce the levels of air pollutants at the markets. However, the higher indoor/outdoor ratios demonstrated that the operation of air conditioning had influence on the levels of bacteria at the markets. It was found that average PM 10 concentration at poultry stalls was higher than the HKIAQO standard of 180 μg/m 3 , and was over two times that measured at vegetable, fish and meat stalls. Furthermore, the concentration of airborne bacteria at the poultry stalls was as high as 1031 CFU/m 3 , which was above the HKIAQO standard of 1000 CFU/m 3 . The bacteria levels at other three stalls were all below the HKIAQO standard

  7. Indoor air pollution

    International Nuclear Information System (INIS)

    Anwar, J.; Hussain, F.

    2005-01-01

    Indoor air pollution after being a neglected subject for a number of years, is attracting attention recently because it is a side effect of energy crisis. About 50% of world's 6 billion population, mostly in developing countries, depend on biomass and coal in the form of wood, dung and crop residues for domestic energy because of poverty. These materials are burnt in simple stoves with incomplete combustion and infants, children and women are exposed to high levels of indoor air pollution for a considerable period, approximately between 2-4 hours daily. Current worldwide trade in wood fuel is over US $7 billion and about 2 million people are employed full time in production and marketing it. One of the most annoying and common indoor pollutant in both, developing and developed countries, is cigarette smoke. Children in gas-equipped homes had higher incidences of respiratory disease. Babies' DNA can be damaged even before they are born if their mothers breathe polluted air. Exposure to indoor air pollution may be responsible for nearly 2 million excess deaths in developing countries and for 4% of the global burden of the disease. Only a few indoor pollutants have been studied in detail. Indoor air pollution is a major health threat on which further research is needed to define the extent of the problem more precisely and to determine solutions by the policy-makers instead of neglecting it because sufferers mostly belong to Third World countries. (author)

  8. Explaining CMS lepton excesses with supersymmetry

    CERN Multimedia

    CERN. Geneva; Prof. Allanach, Benjamin

    2014-01-01

    1) Kostas Theofilatos will give an introduction to CMS result 2) Ben Allanach: Several CMS analyses involving di-leptons have recently reported small 2.4-2.8 sigma local excesses: nothing to get too excited about, but worth keeping an eye on nonetheless. In particular, a search in the $lljj p_T$(miss) channel, a search for $W_R$ in the $lljj$ channel and a di-leptoquark search in the $lljj$ channel and $ljj p_T$(miss) channel have all yielded small excesses. We interpret the first excess in the MSSM, showing that the interpretation is viable in terms of other constraints, despite only having squark masses of around 1 TeV. We can explain the last three excesses with a single R-parity violating coupling that predicts a non-zero contribution to the neutrinoless double beta decay rate.

  9. A Multi-Response Optimization of Thrust Forces, Torques, and the Power of Tapping Operations by Cooling Air in Reinforced and Unreinforced Polyamide PA66

    Directory of Open Access Journals (Sweden)

    Rosario Domingo

    2018-03-01

    Full Text Available The use of cooling air during machining is an environmentally conscious procedure, and its applicability to different processes is a research priority. We studied tapping operations, an important operation in the assembly process, using cooling air with unreinforced polyamide (PA66 and polyamide reinforced with glass fiber (PA66-GF30. These materials are widely used in industry, but their behavior with respect to tapping has not been studied. We analyze the outcomes regarding the thrust force, torque, and power at cutting speeds between 15 and 60 m/min. The experimental tests were executed using cooling air at 22 °C, 2 °C, and −18 °C in dry conditions. The M12 × 1.75 mm taps were high-speed steel, with cobalt as the base material and coatings of TiN and AlCrN. To identify the more influential factors, an analysis of variance was performed, along with multi-response optimization to identify the desirability values. This optimization shows that the optimum for PA66can be found in environments close to 3 °C, while the optimum for PA66-GF30 is found at the minimal temperature studied (−18 °C. Thus, cooling air can be considered an adequate procedure for tapping operations, to increase the sustainability of the manufacturing processes.

  10. CFD simulation research on residential indoor air quality.

    Science.gov (United States)

    Yang, Li; Ye, Miao; He, Bao-Jie

    2014-02-15

    Nowadays people are excessively depending on air conditioning to create a comfortable indoor environment, but it could cause some health problems in a long run. In this paper, wind velocity field, temperature field and air age field in a bedroom with wall-hanging air conditioning running in summer are analyzed by CFD numerical simulation technology. The results show that wall-hanging air conditioning system can undertake indoor heat load and conduct good indoor thermal comfort. In terms of wind velocity, air speed in activity area where people sit and stand is moderate, most of which cannot feel wind flow and meet the summer indoor wind comfort requirement. However, for air quality, there are local areas without ventilation and toxic gases not discharged in time. Therefore it is necessary to take effective measures to improve air quality. Compared with the traditional measurement method, CFD software has many advantages in simulating indoor environment, so it is hopeful for humans to create a more comfortable, healthy living environment by CFD in the future. Copyright © 2013 Elsevier B.V. All rights reserved.

  11. Syndromes associated with nutritional deficiency and excess.

    Science.gov (United States)

    Jen, Melinda; Yan, Albert C

    2010-01-01

    Normal functioning of the human body requires a balance between nutritional intake and metabolism, and imbalances manifest as nutritional deficiencies or excess. Nutritional deficiency states are associated with social factors (war, poverty, famine, and food fads), medical illnesses with malabsorption (such as Crohn disease, cystic fibrosis, and after bariatric surgery), psychiatric illnesses (eating disorders, autism, alcoholism), and medications. Nutritional excess states result from inadvertent or intentional excessive intake. Cutaneous manifestations of nutritional imbalance can herald other systemic manifestations. This contribution discusses nutritional deficiency and excess syndromes with cutaneous manifestations of particular interest to clinical dermatologists. Copyright © 2010. Published by Elsevier Inc.

  12. Operational features and air plasma characteristics of a thermal plasma torch with hollow electrodes

    International Nuclear Information System (INIS)

    Hur, Min; Kim, Keun Su; Hong, Sang Hee

    2003-01-01

    The operational features and thermal plasma characteristics of a plasma torch with hollow electrodes are investigated based on their dependence on input current, gas flow rate and electrode diameter when air is used as a plasma gas. A plasma torch with a hollow cathode and anode has been designed and fabricated, and the arc voltages and thermal efficiencies are measured from its discharge. The newly modified similarity criteria are derived from the measured data related to torch performances. From the fact that these criteria successfully describe both the arc voltage and thermal efficiency behaviour of the torch, depending on its operating and geometrical parameters, it is proved that they can be usefully applied to the design and operation of high power torches. For the numerical modelling of the interior region of the torch, a cold flow analysis is employed along with a simplified balance equation of the Lorentz and gas dynamic drag forces in order to determine a cathode spot position on the cathode surface. The validity of this method is confirmed by comparison of the calculated and measured net powers. As a practically useful result of this analysis, carried out through this numerical and experimental work, it is suggested that low input current, high gas flow rate and relatively large electrode diameter are more favourable as appropriate operating conditions of the torch for the efficient treatment of hazardous organic wastes

  13. Safety by design: effects of operating room floor marking on the position of surgical devices to promote clean air flow compliance and minimise infection risks

    NARCIS (Netherlands)

    de Korne, Dirk F.; van Wijngaarden, Jeroen D. H.; van Rooij, Jeroen; Wauben, Linda S. G. L.; Hiddema, U. Frans; Klazinga, Niek S.

    2012-01-01

    To evaluate the use of floor marking on the positioning of surgical devices within the clean air flow in an operating room (OR) to minimise infection risk. Laminar flow clean air systems are important in preventing infection in ORs but, for optimal results, surgical devices must be correctly

  14. Interaction of smoking and urban air pollution in the etiology of lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Jedrychowski, W

    1983-01-01

    Surveillance of lung cancer incidence based on mortality was carried out over 6 years in Cracow. It appeared that lung cancer death rates among Cracow inhabitants were higher than average rate in the population of Poland but this difference in the large extent could be explained by the greater prevalence of smoking habit in Cracow than in whole Poland. Very intriguing was a substantial excess of lung cancer deaths only in male residents of the city center having the highest level of the air pollution. Since this excess in the lung cancer deaths could not be exclusively explained by smoking or occupational hazards the air pollution should be assumed as a responsible factor. Lack of the similar phenomenon in females living in the city center can be explained by the fact that the air pollution alone is not sufficient cause in the etiology of lung cancer but that in combination with other adverse factors like smoking or occupational hazards it develops its carcinogenic effect.

  15. Game theoretic analysis of congestion, safety and security networks, air traffic and emergency departments

    CERN Document Server

    Zhuang, Jun

    2015-01-01

    Maximizing reader insights into the roles of intelligent agents in networks, air traffic and emergency departments, this volume focuses on congestion in systems where safety and security are at stake, devoting special attention to applying game theoretic analysis of congestion to: protocols in wired and wireless networks; power generation, air transportation and emergency department overcrowding. Reviewing exhaustively the key recent research into the interactions between game theory, excessive crowding, and safety and security elements, this book establishes a new research angle by illustrating linkages between the different research approaches and serves to lay the foundations for subsequent analysis. Congestion (excessive crowding) is defined in this work as all kinds of flows; e.g., road/sea/air traffic, people, data, information, water, electricity, and organisms. Analyzing systems where congestion occurs – which may be in parallel, series, interlinked, or interdependent, with flows one way or both way...

  16. ATLAS Z Excess in Minimal Supersymmetric Standard Model

    International Nuclear Information System (INIS)

    Lu, Xiaochuan; Terada, Takahiro

    2015-06-01

    Recently the ATLAS collaboration reported a 3 sigma excess in the search for the events containing a dilepton pair from a Z boson and large missing transverse energy. Although the excess is not sufficiently significant yet, it is quite tempting to explain this excess by a well-motivated model beyond the standard model. In this paper we study a possibility of the minimal supersymmetric standard model (MSSM) for this excess. Especially, we focus on the MSSM spectrum where the sfermions are heavier than the gauginos and Higgsinos. We show that the excess can be explained by the reasonable MSSM mass spectrum.

  17. Bladder calculus presenting as excessive masturbation.

    Science.gov (United States)

    De Alwis, A C D; Senaratne, A M R D; De Silva, S M P D; Rodrigo, V S D

    2006-09-01

    Masturbation in childhood is a normal behaviour which most commonly begins at 2 months of age, and peaks at 4 years and in adolescence. However excessive masturbation causes anxiety in parents. We describe a boy with a bladder calculus presenting as excessive masturbation.

  18. The excess and the lack in "Eu sou Sartori e o meu partido é o Rio Grande"

    Directory of Open Access Journals (Sweden)

    Ercília Ana Cazarin

    2017-11-01

    Full Text Available This paper placed in Michel Pêcheux’s discourse analysis has the purpose to analyze the statement “EU SOU SARTORI E MEU PARTIDO É O RIO GRANDE” pronounced by the candidate to the Rio Grande do Sul’s government, José Ivo Sartori, during his campaign in 2014. With this investigation, we intend to offer reflections around issues that can, in the verticality of the discourse, help in the comprehension of the excess and the lack both present in the discursive operation in focus. These notions are conceived as limits and interdictions that are imposed on the subject, being the excess, the part that allows the effect of truth and the lack what works as forgetfulness policy. These operations establish meaning effects that can displace, transform, preserve and/or delete senses.

  19. Hyperhidrosis (Excessive Sweating)

    Science.gov (United States)

    ... who have this type are otherwise healthy. In medical terminology, the word “primary” means that the cause is not another medical condition. Secondary hyperhidrosis In medical terminology, “secondary” means that the excessive sweating (hyperhidrosis) has ...

  20. 45 CFR 2543.86 - Clean Air Act and the Federal Water Pollution Control Act.

    Science.gov (United States)

    2010-10-01

    ... 45 Public Welfare 4 2010-10-01 2010-10-01 false Clean Air Act and the Federal Water Pollution... Water Pollution Control Act. Contracts and subgrants of amounts in excess of $100,000 shall contain a... regulations issued pursuant to the Clean Air Act (42 U.S.C. 7401 et seq.) and the Federal Water Pollution...

  1. Forced-air warming blowers: An evaluation of filtration adequacy and airborne contamination emissions in the operating room.

    Science.gov (United States)

    Albrecht, Mark; Gauthier, Robert L; Belani, Kumar; Litchy, Mark; Leaper, David

    2011-05-01

    Forced-air warming (FAW) is widely used to prevent hypothermia during surgical procedures. The airflow from these blowers is often vented near the operative site and should be free of contaminants to minimize the risk of surgical site infection. Popular FAW blowers contain a 0.2-μm rated intake filter to reduce these risks. However, there is little evidence that the efficiency of the intake filter is adequate to prevent airborne contamination emissions or protect the internal air path from microbial contamination buildup. Five new intake filters were obtained directly from the manufacturer (Bair Hugger 505, model 200708D; Arizant Healthcare, Eden Prairie, MN), and 5 model 200708C filters currently in hospital use were removed from FAW devices. The retention efficiency of these filters was assessed using a monodisperse sodium chloride aerosol. In the same hospitals, internal air path surface swabs and hose outlet particle counts were performed on 52 forced-air warming devices (all with the model 200708C filter) to assess internal microbial buildup and airborne contamination emissions. Intake filter retention efficiency at 0.2 μm was 93.8% for the 200708C filter and 61.3% at for the 200708D filter. The 200708D filter obtained directly from the manufacturer has a thinner filtration media than the 200708C filter in current hospital use, suggesting that the observed differences in retention efficiency were due to design changes. Fifty-eight percent of the FAW blowers evaluated were internally generating and emitting airborne contaminants, with microorganisms detected on the internal air path surfaces of 92.3% of these blowers. Isolates of Staphylococcus aureus, coagulase-negative Staphylococcus, and methicillin-resistant S aureus were detected in 13.5%, 3.9%, and 1.9% of FAW blowers, respectively. The design of popular FAW devices using the 200708C filter was found to be inadequate for preventing the internal buildup and emission of microbial contaminants into the

  2. Workplace protection of air-fed visors used in paint spraying operations.

    Science.gov (United States)

    Bolsover, J; Rajan-Sithamparanadarajah, B; Vaughan, N

    2006-04-01

    Air-fed visors are commonly used for protection against exposure to airborne isocyanates during paint spraying. Protection levels for this class of equipment are theoretically adequate, yet isocyanate sensitization in this occupation still occurs. The work reported here set out to establish the level of respiratory protection that is achieved during real paint spraying activities when air-fed visors are used. The work also examined the effects of reduced air supply flow rates on this type of respiratory protection. The workplace study highlighted common problems that occur when attempting to measure protection factors, and process and interpret the collected data. Many of the environments included in this study did not exhibit challenge concentrations high enough to reliably measure the workplace protection factor of this class of device. When detection limits are taken into consideration, the remaining field data suggest that an assigned protection factor in the region of 40 may be appropriate. When well maintained and used in accordance with the manufacturer's instructions, air-fed visors are capable of providing a good level of respiratory protection. The protection given by air-fed visors is strongly dependent on the air flow supplied to them. Laboratory measurements demonstrate that protection falls as the air supply falls. This is a gradual process and does not suddenly occur at any particular air supply flow. Observations made during the field tests indicate that there may be other activities associated with the spraying process that need to be taken into consideration when looking for sources of respiratory sensitization.

  3. A Long-Life Lithium-Air Battery in Ambient Air with a Polymer Electrolyte Containing a Redox Mediator.

    Science.gov (United States)

    Guo, Ziyang; Li, Chao; Liu, Jingyuan; Wang, Yonggang; Xia, Yongyao

    2017-06-19

    Lithium-air batteries when operated in ambient air generally exhibit poor reversibility and cyclability, because of the Li passivation and Li 2 O 2 /LiOH/Li 2 CO 3 accumulation in the air electrode. Herein, we present a Li-air battery supported by a polymer electrolyte containing 0.05 m LiI, in which the polymer electrolyte efficiently alleviates the Li passivation induced by attacking air. Furthermore, it is demonstrated that I - /I 2 conversion in polymer electrolyte acts as a redox mediator that facilitates electrochemical decomposition of the discharge products during recharge process. As a result, the Li-air battery can be stably cycled 400 times in ambient air (relative humidity of 15 %), which is much better than previous reports. The achievement offers a hope to develop the Li-air battery that can be operated in ambient air. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  4. Comparative investigation of thermoelectric air-conditioners versus vapour compression and absorption air-conditioners

    International Nuclear Information System (INIS)

    Riffat, S.B.; Qiu Guoquan

    2004-01-01

    This paper compares the performance of three types of domestic air-conditioners, namely the vapour compression air-conditioner (VCAC), the absorption air-conditioner (AAC) and the thermoelectric air-conditioner (TEAC). The basic cycles of the three types of air-conditioning systems are described and methods to calculate their coefficients of performance are presented. General specification data for each type of air-conditioner are given, and performance characteristics are presented. The comparison shows that although VCACs have the advantages of high COP and low purchase price, use of these systems will be phased out due to their contribution to the greenhouse effect and depletion of the ozone layer. AACs are generally bulky, complex and expensive but operate on thermal energy, so their operational consumption is low. TEACs are environmental friendly, simple and reliable but still very expensive at present. Their low COP is an additional factor limiting their application for domestic cooling. TEACs however, have a large potential market as air-conditioners for small enclosures, such as cars and submarine cabins, where the power consumption would be low, or safety and reliability would be important

  5. Land-mobile satellite excess path loss measurements

    Science.gov (United States)

    Hess, G. C.

    1980-05-01

    An experiment conducted with the ATS-6 satellite to determine the additional path loss over free-space loss experienced by land-mobile communication links is described. This excess path loss is measured as a function of 1) local environment, 2) vehicle heading, 3) link frequency, 4) satellite elevation angle, and 5) street side. A statistical description of excess loss developed from the data shows that the first two parameters dominate. Excess path loss on the order of 25 dB is typical in urban situations, but decreases to under 10 dB in suburban/rural areas. Spaced antenna selection diversity is found to provide only a slight decrease (4 dB, typically) in the urban excess path loss observed. Level crossing rates are depressed in satellite links relative to those of Rayleigh-faded terrestrial links, but increases in average fade durations tend to offset that advantage. The measurements show that the excess path loss difference between 860-MHz links and 1550-MHz links is generally negligible.

  6. Exposure-response functions for health effects of air pollutants based on epidemiological findings

    Energy Technology Data Exchange (ETDEWEB)

    Aunan, K

    1995-10-01

    The objective of this report is to provide exposure-response functions for health effects and air pollution, which can be used in cost-effectiveness analyses of abatement measures. When cost-effective abatement strategies for air pollution are analyzed, and when air quality standards are set, it is important to have quantitative knowledge about health damage. In spite of their shortcomings, epidemiological studies provide a sound basis for exposure-response functions because they involve a random cross section of the population. In this report the exposure-response functions apply to the relation between air pollutant concentrations and relative effect frequencies, and involve the following health effect end-points: acute and chronic respiratory symptoms in children and adults, asthma episodes in children and adults, eye irritations, headache, lung damage in children, excess mortality, lung cancer incidence. The effects are attributed to one indicator component, which in many cases is particles, but for some effects NO{sub 2}, SO{sub 2}, O{sub 3}, or CO. A calculation procedure is suggested which makes it possible to estimate excess annual symptom-days for short-term effects using the annual average concentration. 103 refs., 1 table

  7. Experimental study on premixed CH{sub 4}/air mixture combustion in micro Swiss-roll combustors

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Bei-Jing; Wang, Jian-Hua [Key Laboratory for Thermal Science and Power Engineering of Ministry of Education, Department of Engineering Mechanics, Tsinghua University, Beijing 100084 (China)

    2010-12-15

    Excess enthalpy combustion is a promising approach to stabilize flame in micro-combustors. Using a Swiss-roll combustor configuration, excess enthalpy combustion can be conveniently achieved. In this work, three types of Swiss-roll combustors with double spiral-shaped channels were designed and fabricated. The combustors were tested using methane/air mixtures of various equivalence ratios. Both temperature distributions and extinction limits were determined for each combustor configuration at different methane mass flow rates. Results indicate that the Swiss-roll combustors developed in the current study greatly enhance combustion stability in center regions of the combustors. At the same time, excess enthalpy combustors of the Swiss-roll configuration significantly extend the extinction limits of methane/air mixtures. In addition, the effects of combustor configurations and thermal insulation arrangements on temperature distributions and extinction limits were evaluated. With heat losses to the environment being significant, the use of thermal insulations further enhances the flame stability in center regions of the Swiss-roll combustors and extends flammable ranges. (author)

  8. STOMP Sparse Vegetation Evapotranspiration Model for the Water-Air-Energy Operational Mode

    Energy Technology Data Exchange (ETDEWEB)

    Ward, Anderson L.; White, Mark D.; Freeman, Eugene J.; Zhang, Z. F.

    2005-09-15

    The Water-Air-Energy (WAE) Operational Mode of the Subsurface Transport Over Multiple Phases (STOMP) numerical simulator solves the coupled conservation equations for water mass, air mass, and thermal energy in multiple dimensions. This addendum describes the theory, input file formatting, and application of a soil-vegetation-atmosphere transfer (SVAT) scheme for STOMP that is based on a sparse vegetation evapotranspiration model. The SVAT scheme is implemented as a boundary condition on the upper surface of the computational domain and has capabilities for simulating evaporation from bare surfaces as well as evapotranspiration from sparsely vegetated surfaces populated with single or multiple plant species in response to meteorological forcings. With this extension, the model calculates water mass, air mass and thermal energy across a boundary surface in addition to root-water transport between the subsurface and atmosphere. This mode represents the barrier extension of the WAE mode and is designated as STOMP-WAE-B. Input for STOMP-WAE-B is specified via three input cards and include: atmospheric conditions through the Atmospheric Conditions Card; time-invariant plant species data through the Plant Properties Card; and time varying plant species data through the Boundary Conditions Card. Two optional cards, the Observed Data and UCODE Control Cards allow use of STOMP-WAE with UCODE in an inverse mode to estimate model parameters. STOMP-WAE was validated by solving a number of test problems from the literature that included experimental observations as well as analytical or numerical solutions. Several of the UNSAT-H verification problems are included along with a benchmark simulation derived from a recently published intercode comparison for barrier design tools. Results show that STOMP is able to meet, and in most cases, exceed performance of other commonly used simulation codes without having to resort to may of their simplifying assumptions. Use of the fully

  9. Industrial excess heat for district heating in Denmark

    International Nuclear Information System (INIS)

    Bühler, Fabian; Petrović, Stefan; Karlsson, Kenneth; Elmegaard, Brian

    2017-01-01

    Highlights: •Method for utilisation potential of industrial excess heat for district heating. •Industrial excess heat from thermal processes is quantified at single production units. •Linking of industrial excess heat sources and district heating demands done in GIS. •Excess heat recovery using direct heat transfer and heat pumps. •5.1% of the Danish district heating demand could be supplied by industrial excess heat. -- Abstract: Excess heat is available from various sources and its utilisation could reduce the primary energy use. The accessibility of this heat is however dependent amongst others on the source and sink temperature, amount and potential users in its vicinity. In this work a new method is developed which analyses excess heat sources from the industrial sector and how they could be used for district heating. This method first allocates excess heat to single production units by introducing and validating a new approach. Spatial analysis of the heat sources and consumers are then performed to evaluate the potential for using them for district heating. In this way the theoretical potential of using the excess heat for covering the heating demand of buildings is determined. Through the use of industry specific temperature profiles the heat usable directly or via heat pumps is further found. A sensitivity analysis investigates the impact of future energy efficiency measures in the industry, buildings and the district heating grid on the national potential. The results show that for the case study of Denmark, 1.36 TWh of district heat could be provided annually with industrial excess heat from thermal processes which equals 5.1% of the current demand. More than half of this heat was found to be usable directly, without the need for a heat pump.

  10. Effect of air-water mixture drawoff from condenser discharge chamberson the Chernobylsk NPP turbine operating efficiency

    International Nuclear Information System (INIS)

    Trushin, V.N.; Aleksandrov, I.P.; Borets, V.I.

    1985-01-01

    It is established experimentally that reliable operation of air drawoffs from conden.ser discharge chambers influences greatly on efficiency of a cooling system of low-pressure condensers (LPC). The interacting influence of drawoff lines operating in parallel is outlined, which may, under certain conditions, lead to partial or total neutralization of the drawoff system, that, in its turn, leads to formation of a unique waterfall flow regime in the discharge chamber of LPC outside its partition. Waterfall regime leads to reduction of cooling water flow rate, to partial uncovering of. the fuel element cluster with the proper fall of vacuum and turbine efficiency. Experimental investigations, carried out at a condenser model, permit to find a way and give recommendations to prevent the formation of waterfall regime of outflow

  11. Dynamic Performance of a Residential Air-to-Air Heat Pump.

    Science.gov (United States)

    Kelly, George E.; Bean, John

    This publication is a study of the dynamic performance of a 5-ton air-to-air heat pump in a residence in Washington, D.C. The effect of part-load operation on the heat pump's cooling and heating coefficients of performance was determined. Discrepancies between measured performance and manufacturer-supplied performance data were found when the unit…

  12. Enantiomer excesses of rare and common sugar derivatives in carbonaceous meteorites

    Science.gov (United States)

    Cooper, George; Rios, Andro C.

    2016-06-01

    Biological polymers such as nucleic acids and proteins are constructed of only one—the d or l—of the two possible nonsuperimposable mirror images (enantiomers) of selected organic compounds. However, before the advent of life, it is generally assumed that chemical reactions produced 50:50 (racemic) mixtures of enantiomers, as evidenced by common abiotic laboratory syntheses. Carbonaceous meteorites contain clues to prebiotic chemistry because they preserve a record of some of the Solar System’s earliest (˜4.5 Gy) chemical and physical processes. In multiple carbonaceous meteorites, we show that both rare and common sugar monoacids (aldonic acids) contain significant excesses of the d enantiomer, whereas other (comparable) sugar acids and sugar alcohols are racemic. Although the proposed origins of such excesses are still tentative, the findings imply that meteoritic compounds and/or the processes that operated on meteoritic precursors may have played an ancient role in the enantiomer composition of life’s carbohydrate-related biopolymers.

  13. Enantiomer excesses of rare and common sugar derivatives in carbonaceous meteorites.

    Science.gov (United States)

    Cooper, George; Rios, Andro C

    2016-06-14

    Biological polymers such as nucleic acids and proteins are constructed of only one-the d or l-of the two possible nonsuperimposable mirror images (enantiomers) of selected organic compounds. However, before the advent of life, it is generally assumed that chemical reactions produced 50:50 (racemic) mixtures of enantiomers, as evidenced by common abiotic laboratory syntheses. Carbonaceous meteorites contain clues to prebiotic chemistry because they preserve a record of some of the Solar System's earliest (∼4.5 Gy) chemical and physical processes. In multiple carbonaceous meteorites, we show that both rare and common sugar monoacids (aldonic acids) contain significant excesses of the d enantiomer, whereas other (comparable) sugar acids and sugar alcohols are racemic. Although the proposed origins of such excesses are still tentative, the findings imply that meteoritic compounds and/or the processes that operated on meteoritic precursors may have played an ancient role in the enantiomer composition of life's carbohydrate-related biopolymers.

  14. Continuous Photo-Oxidation in a Vortex Reactor: Efficient Operations Using Air Drawn from the Laboratory.

    Science.gov (United States)

    Lee, Darren S; Amara, Zacharias; Clark, Charlotte A; Xu, Zeyuan; Kakimpa, Bruce; Morvan, Herve P; Pickering, Stephen J; Poliakoff, Martyn; George, Michael W

    2017-07-21

    We report the construction and use of a vortex reactor which uses a rapidly rotating cylinder to generate Taylor vortices for continuous flow thermal and photochemical reactions. The reactor is designed to operate under conditions required for vortex generation. The flow pattern of the vortices has been represented using computational fluid dynamics, and the presence of the vortices can be easily visualized by observing streams of bubbles within the reactor. This approach presents certain advantages for reactions with added gases. For reactions with oxygen, the reactor offers an alternative to traditional setups as it efficiently draws in air from the lab without the need specifically to pressurize with oxygen. The rapid mixing generated by the vortices enables rapid mass transfer between the gas and the liquid phases allowing for a high efficiency dissolution of gases. The reactor has been applied to several photochemical reactions involving singlet oxygen ( 1 O 2 ) including the photo-oxidations of α-terpinene and furfuryl alcohol and the photodeborylation of phenyl boronic acid. The rotation speed of the cylinder proved to be key for reaction efficiency, and in the operation we found that the uptake of air was highest at 4000 rpm. The reactor has also been successfully applied to the synthesis of artemisinin, a potent antimalarial compound; and this three-step synthesis involving a Schenk-ene reaction with 1 O 2 , Hock cleavage with H + , and an oxidative cyclization cascade with triplet oxygen ( 3 O 2 ), from dihydroartemisinic acid was carried out as a single process in the vortex reactor.

  15. A Near-Term Concept for Trajectory Based Operations with Air/Ground Data Link Communication

    Science.gov (United States)

    McNally, David; Mueller, Eric; Thipphavong, David; Paielli, Russell; Cheng, Jinn-Hwei; Lee, Chuhan; Sahlman, Scott; Walton, Joe

    2010-01-01

    An operating concept and required system components for trajectory-based operations with air/ground data link for today's en route and transition airspace is proposed. Controllers are fully responsible for separation as they are today, and no new aircraft equipage is required. Trajectory automation computes integrated solutions to problems like metering, weather avoidance, traffic conflicts and the desire to find and fly more time/fuel efficient flight trajectories. A common ground-based system supports all levels of aircraft equipage and performance including those equipped and not equipped for data link. User interface functions for the radar controller's display make trajectory-based clearance advisories easy to visualize, modify if necessary, and implement. Laboratory simulations (without human operators) were conducted to test integrated operation of selected system components with uncertainty modeling. Results are based on 102 hours of Fort Worth Center traffic recordings involving over 37,000 individual flights. The presence of uncertainty had a marginal effect (5%) on minimum-delay conflict resolution performance, and windfavorable routes had no effect on detection and resolution metrics. Flight plan amendments and clearances were substantially reduced compared to today s operations. Top-of-descent prediction errors are the largest cause of failure indicating that better descent predictions are needed to reliably achieve fuel-efficient descent profiles in medium to heavy traffic. Improved conflict detections for climbing flights could enable substantially more continuous climbs to cruise altitude. Unlike today s Conflict Alert, tactical automation must alert when an altitude amendment is entered, but before the aircraft starts the maneuver. In every other failure case tactical automation prevented losses of separation. A real-time prototype trajectory trajectory-automation system is running now and could be made ready for operational testing at an en route

  16. Influence of wind velocity fluctuation on air temperature difference between the fan and ground levels and the effect of frost protective fan operation

    International Nuclear Information System (INIS)

    Araki, T.; Matsuo, K.; Miyama, D.; Sumikawa, O.; Araki, S.

    2008-01-01

    We invested the influence of wind velocity fluctuation on air temperature difference between the fan (4.8 m) and ground levels (0.5 m) and the effect of frost protective fan operation in order to develop a new method to reduce electricity consumption due to frost protective fan operation. The results of the investigations are summarized as follows: (1) Air temperature difference between the fan (4.8 m) and ground levels (0.5 m) was decreased following an increase in wind velocity, and the difference was less than 1°C for a wind velocity more than 3.0 m/s at a height of 6.5 m. (2) When the wind velocity was more than 2-3 m/s, there was hardly any increase in the temperature of the leaves. In contrast, when the wind velocity was less than 2-3 m/s, an increase in the temperature of the leaves was observed. Based on these results, it is possible that when the wind velocity is greater than 2-3 m, it prevents thermal inversion. Therefore, there would be no warmer air for the frost protective fan to return to the tea plants and the air turbulence produced by the frost protective fan would not reach the plants under the windy condition

  17. Indoor Air Quality in Schools.

    Science.gov (United States)

    Torres, Vincent M.

    Asserting that the air quality inside schools is often worse than outdoor pollution, leading to various health complaints and loss of productivity, this paper details factors contributing to schools' indoor air quality. These include the design, operation, and maintenance of heating, ventilating, and air conditioning (HVAC) systems; building…

  18. Monitoring total endotoxin and (1 --> 3)-beta-D-glucan at the air exhaust of concentrated animal feeding operations.

    Science.gov (United States)

    Yang, Xufei; Wang, Xinlei; Zhang, Yuanhui; Lee, Jongmin; Su, Jingwei; Gates, Richard S

    2013-10-01

    Mitigation of bioaerosol emissions from concentrated animal feeding operations (CAFOs) demands knowledge of bioaerosol concentrations feeding into an end-of-pipe air treatment process. The aim of this preliminary study was to measure total endotoxin and (1 --> 3)-beta-glucan concentrations at the air exhaust of 18 commercial CAFOs and to examine their variability with animal operation type (swine farrowing, swine gestation, swine weaning, swine finishing, manure belt laying hen, and tom turkey) and season (cold, mild, and hot). The measured airborne concentrations of total endotoxin ranged from 98 to 23,157 endotoxin units (EU)/m3, and the airborne concentrations of total (1 --> 3)-beta-D-glucan ranged from 2.4 to 537.9 ng/m3. Animal operation type in this study had a significant effect on airborne concentrations of total endotoxin and (1 --> 3)-beta-D-glucan but no significant effect on their concentrations in total suspended particulate (TSP). Both endotoxin and (1 --> 3)-beta-D-glucan attained their highest airborne concentrations in visited tom turkey buildings. Comparatively, season had no significant effect on airborne concentrations of total endotoxin or (1 --> 3)-beta-D-glucan. Endotoxin and (1 --> 3)-beta-glucan concentrations in TSP dust appeared to increase as the weather became warmer, and this seasonal effect was significant in swine buildings. Elevated indoor temperatures in the hot season were considered to facilitate the growth and propagation of bacteria and fungi, thus leading to higher biocomponent concentrations in TSP.

  19. Understanding Excess Emissions from Industrial Facilities: Evidence from Texas.

    Science.gov (United States)

    Zirogiannis, Nikolaos; Hollingsworth, Alex J; Konisky, David M

    2018-03-06

    We analyze excess emissions from industrial facilities in Texas using data from the Texas Commission on Environmental Quality. Emissions are characterized as excess if they are beyond a facility's permitted levels and if they occur during startups, shutdowns, or malfunctions. We provide summary data on both the pollutants most often emitted as excess emissions and the industrial sectors and facilities responsible for those emissions. Excess emissions often represent a substantial share of a facility's routine (or permitted) emissions. We find that while excess emissions events are frequent, the majority of excess emissions are emitted by the largest events. That is, the sum of emissions in the 96-100th percentile is often several orders of magnitude larger than the remaining excess emissions (i.e., the sum of emissions below the 95th percentile). Thus, the majority of events emit a small amount of pollution relative to the total amount emitted. In addition, a small group of high emitting facilities in the most polluting industrial sectors are responsible for the vast majority of excess emissions. Using an integrated assessment model, we estimate that the health damages in Texas from excess emissions are approximately $150 million annually.

  20. Low-Flow Liquid Desiccant Air Conditioning: General Guidance and Site Considerations

    Energy Technology Data Exchange (ETDEWEB)

    Kozubal, E.; Herrmann, L.; Deru, M.; Clark, J.

    2014-09-01

    Dehumidification or latent cooling in buildings is an area of growing interest that has been identified as needing more research and improved technologies for higher performance. Heating, ventilating, and air-conditioning (HVAC) systems typically expend excessive energy by using overcool-and-reheat strategies to dehumidify buildings. These systems first overcool ventilation air to remove moisture and then reheat the air to meet comfort requirements. Another common strategy incorporates solid desiccant rotors that remove moisture from the air more efficiently; however, these systems increase fan energy consumption because of the high airside pressure drop of solid desiccant rotors and can add heat of absorption to the ventilation air. Alternatively, liquid desiccant air-conditioning (LDAC) technology provides an innovative dehumidification solution that: (1) eliminates the need for overcooling and reheating from traditional cooling systems; and (2) avoids the increased fan energy and air heating from solid desiccant rotor systems.

  1. Low-cost airlines consolidation as a feature of air transpoet globalization

    OpenAIRE

    Maltsev Andrey A.; Matveeva Anastasiya V.

    2017-01-01

    The increased industry consolidation resulting in the formation of new highly organized forms of cooperation is referred as one of the main features of air transport globalization at the present stage. Consolidation allows carriers to overcome the excessive competition and to strengthen their market position. It also helps them to optimize the route network and organizational structure of the company. This article includes the analysis of the dynam-ics of global air passenger traffic by low-c...

  2. Identifying Best Bet Entry-Level Selection Measures for US Air Force Remotely Piloted Aircraft (RPA) Pilot and Sensor Operator (SO) Occupations

    Science.gov (United States)

    2011-12-01

    occupations (pilots, combat system operators, air battle managers) (Carretta, 2008; Carretta & Ree, 2003; Olea & Ree, 1994). This body of knowledge...Ergonomics, 50(7), 1064-1091. O’Hare, D. (1997). Cognitive ability determinants of elite pilot performance. Human Factors, 39, 540-552. Olea

  3. 14 CFR 91.139 - Emergency air traffic rules.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Emergency air traffic rules. 91.139 Section 91.139 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF TRANSPORTATION (CONTINUED) AIR TRAFFIC AND GENERAL OPERATING RULES GENERAL OPERATING AND FLIGHT RULES Flight Rules General § 91.139 Emergency air traffic rules. (a) This...

  4. Characterization of the aging and excess noise of a Hamamatsu fine mesh photopentode

    Energy Technology Data Exchange (ETDEWEB)

    Fujimoto, D., E-mail: fujimoto@phas.ubc.ca; Hearty, C., E-mail: hearty@physics.ubc.ca

    2016-07-01

    The excess noise factor and the aging characteristics of 16 Hamamatsu R11283 photopentodes have been tested. These fine-mesh phototubes are to be paired with pure CsI scintillation crystals considered for use in the endcap calorimeter of the Belle II detector. The average excess noise factor was found to be 1.9±0.1±0.4. The electronic noise of a custom preamplifier produced by the University of Montreal was found as a consequence of this measurement and was 1730±33 electrons, in agreement with previous values. On average, the gain×quantum efficiency was reduced to 92±3% of the initial value after passing an average of 7 C through the anode. This corresponds to 70 years of standard Belle II operation.

  5. Excessive Testing and Pupils in the Public Schools

    Science.gov (United States)

    Ediger, Marlow

    2017-01-01

    This article explores the question of excessive testing in public schools, its value in the educational process, and the impact that excessive testing may have on the student and the family unit. While assessments are valuable when used properly, excessive testing may lead to problems with unforeseen consequences.

  6. Can we determine what controls the spatio-temporal distribution of d-excess and 17O-excess in precipitation using the LMDZ general circulation model?

    Directory of Open Access Journals (Sweden)

    C. Risi

    2013-09-01

    Full Text Available Combined measurements of the H218O and HDO isotopic ratios in precipitation, leading to second-order parameter D-excess, have provided additional constraints on past climates compared to the H218O isotopic ratio alone. More recently, measurements of H217O have led to another second-order parameter: 17O-excess. Recent studies suggest that 17O-excess in polar ice may provide information on evaporative conditions at the moisture source. However, the processes controlling the spatio-temporal distribution of 17O-excess are still far from being fully understood. We use the isotopic general circulation model (GCM LMDZ to better understand what controls d-excess and 17O-excess in precipitation at present-day (PD and during the last glacial maximum (LGM. The simulation of D-excess and 17O-excess is evaluated against measurements in meteoric water, water vapor and polar ice cores. A set of sensitivity tests and diagnostics are used to quantify the relative effects of evaporative conditions (sea surface temperature and relative humidity, Rayleigh distillation, mixing between vapors from different origins, precipitation re-evaporation and supersaturation during condensation at low temperature. In LMDZ, simulations suggest that in the tropics convective processes and rain re-evaporation are important controls on precipitation D-excess and 17O-excess. In higher latitudes, the effect of distillation, mixing between vapors from different origins and supersaturation are the most important controls. For example, the lower d-excess and 17O-excess at LGM simulated at LGM are mainly due to the supersaturation effect. The effect of supersaturation is however very sensitive to a parameter whose tuning would require more measurements and laboratory experiments. Evaporative conditions had previously been suggested to be key controlling factors of d-excess and 17O-excess, but LMDZ underestimates their role. More generally, some shortcomings in the simulation of 17O-excess

  7. 29 CFR 1917.154 - Compressed air.

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false Compressed air. 1917.154 Section 1917.154 Labor Regulations...) MARINE TERMINALS Related Terminal Operations and Equipment § 1917.154 Compressed air. Employees shall be... this part during cleaning with compressed air. Compressed air used for cleaning shall not exceed a...

  8. New vector bosons and the diphoton excess

    Directory of Open Access Journals (Sweden)

    Jorge de Blas

    2016-08-01

    Full Text Available We consider the possibility that the recently observed diphoton excess at ∼750 GeV can be explained by the decay of a scalar particle (φ to photons. If the scalar is the remnant of a symmetry-breaking sector of some new gauge symmetry, its coupling to photons can be generated by loops of the charged massive vectors of the broken symmetry. If these new W′ vector bosons carry color, they can also generate an effective coupling to gluons. In this case the diphoton excess could be entirely explained in a simplified model containing just φ and W′. On the other hand, if W′ does not carry color, we show that, provided additional colored particles exist to generate the required φ to gluon coupling, the diphoton excess could be explained by the same W′ commonly invoked to explain the diboson excess at ∼2 TeV. We also explore possible connections between the diphoton and diboson excesses with the anomalous tt¯ forward–backward asymmetry.

  9. Aluminum-air battery crystallizer

    Science.gov (United States)

    Maimoni, A.

    1987-01-01

    A prototype crystallizer system for the aluminum-air battery operated reliably through simulated startup and shutdown cycles and met its design objectives. The crystallizer system allows for crystallization and removal of the aluminium hydroxide reaction product; it is required to allow steady-state and long-term operation of the aluminum-air battery. The system has to minimize volume and maintain low turbulence and shear to minimize secondary nucleation and energy consumption while enhancing agglomeration. A lamella crystallizer satisfies system constraints.

  10. Experimental analysis of indoor air quality improvement achieved by using a Clean-Air Heat Pump (CAHP) air-cleaner in a ventilation system

    DEFF Research Database (Denmark)

    Sheng, Ying; Fang, Lei; Nie, Jinzhe

    2017-01-01

    This study investigated the air purification effect of a Clean-Air Heat Pump (CAHP) air-cleaner which combined a silica gel rotor with a heat pump to achieve air cleaning, heating and ventilation in buildings. The experiments were conducted in a field laboratory and compared a low outdoor air...... supply rate with CAHP air purification of recirculated air with three different outdoor air supply rates without recirculation or air cleaning. Sensory assessments of perceived air quality and chemical measurements of TVOC concentration were used to evaluate the air-cleaning performance of the CAHP....... The results of the experiment showed that the operation of the CAHP significantly improved the perceived air quality in a room polluted by both human bio-effluents and building materials. At the outdoor airflow rate of 2 L/s per person, the indoor air quality with CAHP was equivalent to what was achieved...

  11. Health and efficiency in trimix versus air breathing in compressed air workers.

    Science.gov (United States)

    Van Rees Vellinga, T P; Verhoeven, A C; Van Dijk, F J H; Sterk, W

    2006-01-01

    The Western Scheldt Tunneling Project in the Netherlands provided a unique opportunity to evaluate the effects of trimix usage on the health of compressed air workers and the efficiency of the project. Data analysis addressed 318 exposures to compressed air at 3.9-4.4 bar gauge and 52 exposures to trimix (25% oxygen, 25% helium, and 50% nitrogen) at 4.6-4.8 bar gauge. Results revealed three incidents of decompression sickness all of which involved the use of compressed air. During exposure to compressed air, the effects of nitrogen narcosis were manifested in operational errors and increased fatigue among the workers. When using trimix, less effort was required for breathing, and mandatory decompression times for stays of a specific duration and maximum depth were considerably shorter. We conclude that it might be rational--for both medical and operational reasons--to use breathing gases with lower nitrogen fractions (e.g., trimix) for deep-caisson work at pressures exceeding 3 bar gauge, although definitive studies are needed.

  12. Evaluation of personal air sampling pumps

    International Nuclear Information System (INIS)

    Ritter, P.D.; Novick, V.J.; Alvarez, J.L.; Huntsman, B.L.

    1987-01-01

    Personal air samplers are used to more conveniently obtain breathing zone samples from individuals over periods of several hours. Personal air sampling pumps must meet minimum performance levels under all working conditions to be suitable for use in radiation protection programs. In addition, the pumps should be simple to operate and as comfortable to wear as possible. Ten models of personal air sampling pumps were tested to evaluate their mechanical performance and physical characteristics. The pumps varied over a wide range in basic performance and operating features. Some of the pumps were found to have adequate performance for use in health physics air sampling applications. 3 references, 2 figures, 5 tables

  13. Assessing future trends in indoor air quality

    International Nuclear Information System (INIS)

    van de Wiel, H.J.; Lebret, E.; van der Lingen, W.K.; Eerens, H.C.; Vaas, L.H.; Leupen, M.J.

    1990-01-01

    Several national and international health organizations have derived concentration levels below which adverse effects on men are not expected or levels below which the excess risk for individuals is less than a specified value. For every priority pollutant indoor concentrations below this limit are considered healthy. The percentage of Dutch homes exceeding such a limit is taken as a measure of indoor air quality for that component. The present and future indoor air quality of the Dutch housing stock is described for fourteen air pollutants. The highest percentages are scored by radon, environmental tobacco smoke, nitrogen dioxide from unvented combustion, and the potential presence of housedust mite and mould allergen in damp houses. Although the trend for all priority pollutants is downward the most serious ones remain high in the coming decades if no additional measures will be instituted

  14. Development of the GEM-MACH-FireWork System: An Air Quality Model with On-line Wildfire Emissions within the Canadian Operational Air Quality Forecast System

    Science.gov (United States)

    Pavlovic, Radenko; Chen, Jack; Beaulieu, Paul-Andre; Anselmp, David; Gravel, Sylvie; Moran, Mike; Menard, Sylvain; Davignon, Didier

    2014-05-01

    A wildfire emissions processing system has been developed to incorporate near-real-time emissions from wildfires and large prescribed burns into Environment Canada's real-time GEM-MACH air quality (AQ) forecast system. Since the GEM-MACH forecast domain covers Canada and most of the U.S.A., including Alaska, fire location information is needed for both of these large countries. During AQ model runs, emissions from individual fire sources are injected into elevated model layers based on plume-rise calculations and then transport and chemistry calculations are performed. This "on the fly" approach to the insertion of the fire emissions provides flexibility and efficiency since on-line meteorology is used and computational overhead in emissions pre-processing is reduced. GEM-MACH-FireWork, an experimental wildfire version of GEM-MACH, was run in real-time mode for the summers of 2012 and 2013 in parallel with the normal operational version. 48-hour forecasts were generated every 12 hours (at 00 and 12 UTC). Noticeable improvements in the AQ forecasts for PM2.5 were seen in numerous regions where fire activity was high. Case studies evaluating model performance for specific regions and computed objective scores will be included in this presentation. Using the lessons learned from the last two summers, Environment Canada will continue to work towards the goal of incorporating near-real-time intermittent wildfire emissions into the operational air quality forecast system.

  15. Assessment of operating room airflow using air particle counts and direct observation of door openings.

    Science.gov (United States)

    Teter, Jonathan; Guajardo, Isabella; Al-Rammah, Tamrah; Rosson, Gedge; Perl, Trish M; Manahan, Michele

    2017-05-01

    The role of the operating room (OR) environment has been thought to contribute to surgical site infection rates. The quality of OR air, disruption of airflow, and other factors may increase contamination risks. We measured air particulate counts (APCs) to determine if they increased in relation to traffic, door opening, and other common activities. During 1 week, we recorded APCs in 5-minute intervals and movement of health care workers. Trained observers recorded information about traffic, door openings, job title of the opener, and the reason for opening. At least 1 OR door was open during 47% of all readings. There were 13.4 door openings per hour during cases. Door opening rates ranged from 0.19-0.28 per minute. During this time, a total of 660 air measurements were obtained. The mean APCs were 9,238 particles (95% confidence interval [CI], 5,494- 12,982) at baseline and 14,292 particles (95% CI, 12,382-16,201) during surgery. Overall APCs increased 13% when either door was opened (P opening. We observed numerous instances of verbal communication and equipment movement. Improving efficiency of communication and equipment can aid in reduction of traffic. Further study is needed to examine links between microbiologic sampling, outcome data, and particulate matter to enable study of risk factors and effects of personnel movement. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  16. Air pollution sources, impact and monitoring

    International Nuclear Information System (INIS)

    Qureshi, I.H.

    1999-01-01

    Improper management of socio-economic developmental activities has put a great stress on natural resources and eco-systems and has caused environmental degradation. Indiscriminate release of toxic substances into the atmosphere from power generation, industrial operations, transportation, incineration of waste and other operations has affected the quality of ambient air. Combustion of fossil fuel results in the emission of oxides of carbon, sulfur and nitrogen, particulate and organic compounds which affect the local, regional and global environment. Industrial operations release a wide variety of pollutants which directly affect the local environment. Operation of automobiles releases oxides of carbon, sulfur and nitrogen, hydrocarbons, traces of heavy metals and toxic polycyclic aromatic compounds whereas incineration of municipal waste releases particulate, acid fumes and photochemically reactive and odorous compounds. These air pollutants have varying impacts on health and environment. The intake of polluted air may produce various physiological disorders ranging from respiratory diseases to changes in blood chemistry. Therefore, the emission of pollutants should be controlled at the source and monitoring the levels of pollution should assess the quality of air. (author)

  17. A Study on the Effects of Compression Ratio, Engine Speed and Equivalence Ratio on HCCI Combustion of DME

    DEFF Research Database (Denmark)

    Pedersen, Troels Dyhr; Schramm, Jesper

    2007-01-01

    An experimental study has been carried out on the homogeneous charge compression ignition (HCCI) combustion of Dimethyl Ether (DME). The study was performed as a parameter variation of engine speed and compression ratio on excess air ratios of approximately 2.5, 3 and 4. The compression ratio...... was adjusted in steps to find suitable regions of operation, and the effect of engine speed was studied at 1000, 2000 and 3000 RPM. It was found that leaner excess air ratios require higher compression ratios to achieve satisfactory combustion. Engine speed also affects operation significantly....

  18. ON INFRARED EXCESSES ASSOCIATED WITH Li-RICH K GIANTS

    Energy Technology Data Exchange (ETDEWEB)

    Rebull, Luisa M. [Spitzer Science Center (SSC) and Infrared Science Archive (IRSA), Infrared Processing and Analysis Center - IPAC, 1200 E. California Blvd., California Institute of Technology, Pasadena, CA 91125 (United States); Carlberg, Joleen K. [NASA Goddard Space Flight Center, Code 667, Greenbelt, MD 20771 (United States); Gibbs, John C.; Cashen, Sarah; Datta, Ashwin; Hodgson, Emily; Lince, Megan [Glencoe High School, 2700 NW Glencoe Rd., Hillsboro, OR 97124 (United States); Deeb, J. Elin [Bear Creek High School, 9800 W. Dartmouth Pl., Lakewood, CO 80227 (United States); Larsen, Estefania; Altepeter, Shailyn; Bucksbee, Ethan; Clarke, Matthew [Millard South High School, 14905 Q St., Omaha, NE 68137 (United States); Black, David V., E-mail: rebull@ipac.caltech.edu [Walden School of Liberal Arts, 4230 N. University Ave., Provo, UT 84604 (United States)

    2015-10-15

    Infrared (IR) excesses around K-type red giants (RGs) have previously been discovered using Infrared Astronomy Satellite (IRAS) data, and past studies have suggested a link between RGs with overabundant Li and IR excesses, implying the ejection of circumstellar shells or disks. We revisit the question of IR excesses around RGs using higher spatial resolution IR data, primarily from the Wide-field Infrared Survey Explorer. Our goal was to elucidate the link between three unusual RG properties: fast rotation, enriched Li, and IR excess. Our sample of RGs includes those with previous IR detections, a sample with well-defined rotation and Li abundance measurements with no previous IR measurements, and a large sample of RGs asserted to be Li-rich in the literature; we have 316 targets thought to be K giants, about 40% of which we take to be Li-rich. In 24 cases with previous detections of IR excess at low spatial resolution, we believe that source confusion is playing a role, in that either (a) the source that is bright in the optical is not responsible for the IR flux, or (b) there is more than one source responsible for the IR flux as measured in IRAS. We looked for IR excesses in the remaining sources, identifying 28 that have significant IR excesses by ∼20 μm (with possible excesses for 2 additional sources). There appears to be an intriguing correlation in that the largest IR excesses are all in Li-rich K giants, though very few Li-rich K giants have IR excesses (large or small). These largest IR excesses also tend to be found in the fastest rotators. There is no correlation of IR excess with the carbon isotopic ratio, {sup 12}C/{sup 13}C. IR excesses by 20 μm, though relatively rare, are at least twice as common among our sample of Li-rich K giants. If dust shell production is a common by-product of Li enrichment mechanisms, these observations suggest that the IR excess stage is very short-lived, which is supported by theoretical calculations. Conversely, the

  19. Aging and service wear of air-operated valves used in safety-related systems at nuclear power plants

    International Nuclear Information System (INIS)

    Cox, D.F.; McElhaney, K.L.; Staunton, R.H.

    1995-05-01

    Air-operated valves (AOVs) are used in a variety of safety-related applications at nuclear power plants. They are often used where rapid stroke times are required or precise control of the valve obturator is required. They can be designed to operate automatically upon loss of power, which is often desirable when selecting components for response to design basis conditions. The purpose of this report is to examine the reported failures of AOVs and determine whether there are identifiable trends in the failures related to predictable causes. This report examines the specific components that comprise a typical AOV, how those components fail, when they fail, and how such failures are discovered. It also examines whether current testing frequencies and methods are effective in predicting such failures

  20. Strategic Implications of U.S. Fighter Force Reductions: Air-to-Air Combat Modeling Using Lanchester Equations

    Science.gov (United States)

    2011-06-01

    STRATEGIC IMPLICATIONS OF US FIGHTER FORCE REDUCTIONS: AIR-TO-AIR COMBAT MODELING USING LANCHESTER ...TO-AIR COMBAT MODELING USING LANCHESTER EQUATIONS GRADUATE RESEARCH PAPER Presented to the Faculty Department of Operational Sciences...MODELING USING LANCHESTER EQUATIONS Ronald E. Gilbert, BS, MBA Major, USAF Approved

  1. REAL-TIME EMISSION CHARACTERIZATION OF ORGANIC AIR TOXIC POLLUTANTS DURING STEADY STATE AND TRANSIENT OPERATION OF A MEDIUM DUTY DIESEL ENGINE

    Science.gov (United States)

    An on-line monitoring method, jet resonance-enhanced multi-photon ionization (REMPI) with time-of-flight mass spectrometry (TOFMS) was used to measure emissions of organic air toxics from a medium-duty (60 kW)diesel generator during transient and steady state operations. Emission...

  2. The Small Aircraft Transportation System (SATS), Higher Volume Operations (HVO) Off-Nominal Operations

    Science.gov (United States)

    Baxley, B.; Williams, D.; Consiglio, M.; Conway, S.; Adams, C.; Abbott, T.

    2005-01-01

    The ability to conduct concurrent, multiple aircraft operations in poor weather, at virtually any airport, offers an important opportunity for a significant increase in the rate of flight operations, a major improvement in passenger convenience, and the potential to foster growth of charter operations at small airports. The Small Aircraft Transportation System, (SATS) Higher Volume Operations (HVO) concept is designed to increase traffic flow at any of the 3400 nonradar, non-towered airports in the United States where operations are currently restricted to one-in/one-out procedural separation during Instrument Meteorological Conditions (IMC). The concept's key feature is pilots maintain their own separation from other aircraft using procedures, aircraft flight data sent via air-to-air datalink, cockpit displays, and on-board software. This is done within the Self-Controlled Area (SCA), an area of flight operations established during poor visibility or low ceilings around an airport without Air Traffic Control (ATC) services. The research described in this paper expands the HVO concept to include most off-nominal situations that could be expected to occur in a future SATS environment. The situations were categorized into routine off-nominal operations, procedural deviations, equipment malfunctions, and aircraft emergencies. The combination of normal and off-nominal HVO procedures provides evidence for an operational concept that is safe, requires little ground infrastructure, and enables concurrent flight operations in poor weather.

  3. Air transport system

    CERN Document Server

    Schmitt, Dieter

    2016-01-01

    The book addresses all major aspects to be considered for the design and operation of aircrafts within the entire transportation chain. It provides the basic information about the legal environment, which defines the basic requirements for aircraft design and aircraft operation. The interactions between  airport, air traffic management and the airlines are described. The market forecast methods and the aircraft development process are explained to understand the very complex and risky business of an aircraft manufacturer. The principles of flight physics as basis for aircraft design are presented and linked to the operational and legal aspects of air transport including all environmental impacts. The book is written for graduate students as well as for engineers and experts, who are working in aerospace industry, at airports or in the domain of transport and logistics.

  4. A Case for Including Air Power in the 1998 FM 100-5, Operations

    National Research Council Canada - National Science Library

    Forshee, Charles

    1997-01-01

    The 1998 draft FM 100-5 does not adequately recognize air power. The manual does not adequately recognize air power because it does not address airlift, air space control, or air interdiction in a systemic or logical manner...

  5. Identifying Fixed Support Costs in Air Force Visibility and Management of Operating and Support Costs (VAMOSC).

    Science.gov (United States)

    1983-04-01

    Algorithms I: Overview," Technical Report No. 115-2, Desmatics, Inc., 1983. 6. C. T. Horngren , Cost Accounting : A Managerial Emphasis, Prentice-Hall Inc...CHART NATIONA BUREAUJ OF STAf4DARO-I% 3-A S . . . . . . . . . . I.I i ". ’ 1).N’r1F𔃻I."U FmiXE Sc’pioir COSTS IN A VA,(),C * by Robert L. Gardner Dennis...operations and support (O& S ) costs for Air Force aircraft weapon systems and ground communications-electronics (C-E) systems. Included are fuel, materiel, pay

  6. 31 CFR 353.12 - Disposition of excess.

    Science.gov (United States)

    2010-07-01

    ... necessary to adjust the excess. Instructions for adjustment of the excess can be obtained by email at [email protected] or by writing to Bureau of the Public Debt, Parkersburg, WV 26106-1328. [68 FR 24805...

  7. The Role of Androgen Excess in Metabolic Dysfunction in Women : Androgen Excess and Female Metabolic Dysfunction.

    Science.gov (United States)

    Escobar-Morreale, Héctor F

    2017-01-01

    Polycystic ovary syndrome (PCOS) is characterized by the association of androgen excess with chronic oligoovulation and/or polycystic ovarian morphology, yet metabolic disorders and classic and nonclassic cardiovascular risk factors cluster in these women from very early in life. This chapter focuses on the mechanisms underlying the association of PCOS with metabolic dysfunction, focusing on the role of androgen excess on the development of visceral adiposity and adipose tissue dysfunction.

  8. Operation experience at the UWTF

    International Nuclear Information System (INIS)

    Ueno, Kazuhiro; Inada, Kameji; Ohmori, Kouji; Usui, Kazuya; Irinouchi, Sigenori; Asami, Makoto; Tohchi, Katsunori

    2003-01-01

    This report describes the operation experience on the volume reduction of metal wastes and used air filters contaminated with uranium at the Uranium contaminated Waste Treatment Facility (UWTF) in JNC Tokai Works. The UWTF consists of the metal waste treatment system and the filter-waste treatment system. The former treats metal wastes, the latter treats used air filters. Metal wastes are unpacked from drums, cut, and then compacted. Used air filters are separated into filter media and frames. Then the filter media are compacted and the frames are crushed. The operation of the UWTF was started in June 1998. The following volumes of wastes had been treated at the UWTF from the beginning of the operation to March 2003 (for about 5 years). (1) 1,524 drums of the metal wastes had been reduced to 410 drums. The volume reduction factor was 3.7. (2) 372 drums of the used air filters had been reduced to 39 drums. The volume reduction factor was 9.5. These systems have been operated without trouble for 5 years and have demonstrated to be able to reduce the volumes of the wastes to designed values. The volume reduction technologies for metal wastes and used air filters contaminated with uranium were successfully demonstrated at the UWTF. (author)

  9. Multi-Agent Technology for Air Space Deconfliction

    National Research Council Canada - National Science Library

    Skormin, Victor

    2008-01-01

    .... It is a project specifically dedicated to the problem of air traffic control within airport air space in emergency situations when a hijacked aircraft appears and operates in the airport air space...

  10. Air quality management in Riga area

    Energy Technology Data Exchange (ETDEWEB)

    Leitass, A. [Riga City Council (Latvia). Air Monitoring Dept.

    1995-12-31

    The present Air Quality Management System was started in 1992 as a result of co-operation between two cities - Riga and Norrkoping (Sweden) supported by BITS (The Swedish Agency for International Technical and Economic Co-operation). Lots of Swedish companies were involved in different parts of this project. The strategy is designed by INDIC company developing the AIRVIRO which is a computer based system for all aspects of air quality management. Air pollution in Riga is a serious problem affecting health and damaging valuable buildings of historic value. The majority of the city`s air pollution is the result of emission sources inside the city. The traffic is the predominant source of pollution now. The fossil fuel power stations in the country are not considered to affect the air quality situation in Riga. (author)

  11. Air quality management in Riga area

    Energy Technology Data Exchange (ETDEWEB)

    Leitass, A [Riga City Council (Latvia). Air Monitoring Dept.

    1996-12-31

    The present Air Quality Management System was started in 1992 as a result of co-operation between two cities - Riga and Norrkoping (Sweden) supported by BITS (The Swedish Agency for International Technical and Economic Co-operation). Lots of Swedish companies were involved in different parts of this project. The strategy is designed by INDIC company developing the AIRVIRO which is a computer based system for all aspects of air quality management. Air pollution in Riga is a serious problem affecting health and damaging valuable buildings of historic value. The majority of the city`s air pollution is the result of emission sources inside the city. The traffic is the predominant source of pollution now. The fossil fuel power stations in the country are not considered to affect the air quality situation in Riga. (author)

  12. Radiation dose to the operator during fluoroscopically guided spine procedures

    Energy Technology Data Exchange (ETDEWEB)

    Roccatagliata, Luca; Pravata, Emanuele; Cianfoni, Alessandro [Department of Neuroradiology, Neurocenter of Southern Switzerland, Ospedale Regionale di Lugano, Lugano (Switzerland); Presilla, Stefano [Unita di Fisica Medica, Ente Ospedaliero Cantonale (EOC), Bellinzona (Switzerland)

    2017-09-15

    Fluoroscopy is widely used to guide diagnostic and therapeutic spine procedures. The purpose of this study was to quantify radiation incident on the operator (operator Air Kerma) during a wide range of fluoroscopy-guided spine procedures and its correlation with the amount of radiation incident on the patient (Kerma Area Product - KAP). We retrospectively included 57 consecutive fluoroscopically guided spine procedures. KAP [Gy cm{sup 2}] and total fluoroscopy time were recorded for each procedure. An electronic dosimeter recorded the operator Air Kerma [μGy] for each procedure. Operator Air Kerma for each procedure, correlation between KAP and operator Air Kerma, and between KAP and fluoroscopy time was obtained. Operator Air Kerma was widely variable across procedures, with median value of 6.4 μGy per procedure. Median fluoroscopy time and median KAP per procedure were 2.6 min and 4.7 Gy cm{sup 2}, respectively. There was correlation between operator Air Kerma and KAP (r{sup 2} = 0.60), with a slope of 1.6 μGy Air Kerma per unit Gy cm{sup 2} KAP incident on the patient and between fluoroscopy time and KAP (r{sup 2} = 0.63). Operator Air Kerma during individual fluoroscopy-guided spine procedures can be approximated from the commonly and readily available information of the total amount of radiation incident on the patient, measured as KAP. (orig.)

  13. Air filters for use at nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    Linder, P [Aktiebolaget Atomenergi, Studsvik, Nykoeping (Sweden)

    1970-12-01

    The ventilation system of a nuclear facility plays a vital role in ensuring that the air in working areas and the environment remains free from radioactive contamination. An earlier IAEA publication, Techniques for Controlling Air Pollution from the Operation of Nuclear Facilities, Safety Series No. 17, deals with the design and operation of ventilation systems at nuclear facilities. These systems are usually provided with air-cleaning devices which remove the contaminants from the air. This publication is intended as a guide to those who are concerned with the design of air-filtering systems and with the testing, operation and maintenance of air-filter installations at nuclear facilities. Emphasis is mainly placed on so-called high-efficiency particulate air filters (HEPA filters) and on providing general information on them. Besides describing the usual filter types, their dimensions and construction materials, the guidebook attempts to explain their properties and behaviour under different operating conditions. It also gives advice on testing and handling the filters so that effective and safe performance is ensured. The guidebook should serve as an introduction to the use of high efficiency particulate air filters in countries where work with radioactive materials has only recently commenced. The list of references at the end of the book indicates sources of more advanced information for those who already have comprehensive experience in this field. It is assumed here that the filters are obtained from a manufacturer, and the guidebook thus contains no information on the design and development of the filter itself, nor does it deal with the cleaning of the intake air to a plant, with gas sorption or protective respiratory equipment.

  14. Air filters for use at nuclear facilities

    International Nuclear Information System (INIS)

    Linder, P.

    1970-01-01

    The ventilation system of a nuclear facility plays a vital role in ensuring that the air in working areas and the environment remains free from radioactive contamination. An earlier IAEA publication, Techniques for Controlling Air Pollution from the Operation of Nuclear Facilities, Safety Series No. 17, deals with the design and operation of ventilation systems at nuclear facilities. These systems are usually provided with air-cleaning devices which remove the contaminants from the air. This publication is intended as a guide to those who are concerned with the design of air-filtering systems and with the testing, operation and maintenance of air-filter installations at nuclear facilities. Emphasis is mainly placed on so-called high-efficiency particulate air filters (HEPA filters) and on providing general information on them. Besides describing the usual filter types, their dimensions and construction materials, the guidebook attempts to explain their properties and behaviour under different operating conditions. It also gives advice on testing and handling the filters so that effective and safe performance is ensured. The guidebook should serve as an introduction to the use of high efficiency particulate air filters in countries where work with radioactive materials has only recently commenced. The list of references at the end of the book indicates sources of more advanced information for those who already have comprehensive experience in this field. It is assumed here that the filters are obtained from a manufacturer, and the guidebook thus contains no information on the design and development of the filter itself, nor does it deal with the cleaning of the intake air to a plant, with gas sorption or protective respiratory equipment

  15. The microbiological quality of air improves when using air conditioning systems in cars.

    Science.gov (United States)

    Vonberg, Ralf-Peter; Gastmeier, Petra; Kenneweg, Björn; Holdack-Janssen, Hinrich; Sohr, Dorit; Chaberny, Iris F

    2010-06-01

    Because of better comfort, air conditioning systems are a common feature in automobiles these days. However, its impact on the number of particles and microorganisms inside the vehicle--and by this its impact on the risk of an allergic reaction--is yet unknown. Over a time period of 30 months, the quality of air was investigated in three different types of cars (VW Passat, VW Polo FSI, Seat Alhambra) that were all equipped with a automatic air conditioning system. Operation modes using fresh air from outside the car as well as circulating air from inside the car were examined. The total number of microorganisms and the number of mold spores were measured by impaction in a high flow air sampler. Particles of 0.5 to 5.0 microm diameter were counted by a laser particle counter device. Overall 32 occasions of sampling were performed. The concentration of microorganisms outside the cars was always higher than it was inside the cars. Few minutes after starting the air conditioning system the total number of microorganisms was reduced by 81.7%, the number of mold spores was reduced by 83.3%, and the number of particles was reduced by 87.8%. There were no significant differences neither between the types of cars nor between the types of operation mode of the air conditioning system (fresh air vs. circulating air). All parameters that were looked for in this study improved during utilization of the car's air conditioning system. We believe that the risk of an allergic reaction will be reduced during use also. Nevertheless, we recommend regular maintenance of the system and replacement of older filters after defined changing intervals.

  16. Climate change impacts on projections of excess mortality at ...

    Science.gov (United States)

    We project the change in ozone-related mortality burden attributable to changes in climate between a historical (1995-2005) and near-future (2025-2035) time period while incorporating a non-linear and synergistic effect of ozone and temperature on mortality. We simulate air quality from climate projections varying only biogenic emissions and holding anthropogenic emissions constant, thus attributing changes in ozone only to changes in climate and independent of changes in air pollutant emissions. We estimate non-linear, spatially varying, ozone-temperature risk surfaces for 94 US urban areas using observeddata. Using the risk surfaces and climate projections we estimate daily mortality attributable to ozone exceeding 40 p.p.b. (moderate level) and 75 p.p.b. (US ozone NAAQS) for each time period. The average increases in city-specific median April-October ozone and temperature between time periods are 1.02 p.p.b. and 1.94 °F; however, the results variedby region . Increases in ozone because of climate change result in an increase in ozone mortality burden. Mortality attributed to ozone exceeding 40 p.p.b. increases by 7.7% (1 .6-14.2%). Mortality attributed to ozone exceeding 75 p.p.b. increases by 14.2% (1.628.9%). The absolute increase in excess ozone mortality is larger for changes in moderate ozone levels, reflecting the larger number of days with moderate ozone levels. In this study we evaluate changes in ozone related mortality due to changes in biogenic f

  17. Effect of efficient supply of pure O2 concentrated by PSA-type O2 separator on improvement of indoor air quality

    International Nuclear Information System (INIS)

    Han, Gi Bo; Jang, Jung Hee; Choi, Changsik; Lee, Tae Jin

    2016-01-01

    To minimize the cost and loss rate of energy artificial room ventilation system, the O 2 separator was suggested for the flow of the excessive ventilation amount between indoor and outdoor because the pure O 2 separated and concentrated by the O 2 separator can be supplied with the ventilation amount minimized. How the O 2 separator applies to ventilation and its operation characteristics were investigated by controlling under various conditions as well as the operation conditions optimized required for indoor air quality such as the concentration of CO 2 and O 2 . Consequently, it was known that the O 2 concentration was increased; however, the increase of the CO 2 concentration was suppressed by the sufficient supply of O 2 concentrated from the storage tank into the room despite the two persons’ breathing in the room having an inner volume of about 56m 3 . Consequently, it was concluded that the supply system of the concentrated O 2 which was stored into the tank after the production with the O 2 separator can be applied to the room ventilation system for the improvement of the indoor air quality.

  18. Air Filtration as Protection against Fouling of Ventilation and Air Conditioning Units

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Lajčíková, Ariana

    2005-01-01

    Currently, air filters are one of the most critical components of air treatment systems as they decontaminate the air delivered to living space. During the operation, however, the level of harmful surface deposits increases, and at certain times, an uncleaned filter can itself become a source...... of undesirable contaminents influencing negatively the IAQ of a living space. This is the phenomenon that has been a subject of the current research. The article presents a new, alternative view on indoor air contaminents and filtration requirements. It describes alternative means of filtration and assesses...... issues of inadequate maintenance and/or long term use of applied air filters. An experimental method of evealuating the air quality by means of chemical analysis and state-of-the-art spectrometer is also described....

  19. Air Traffic Management Technology Demostration Phase 1 (ATD) Interval Management for Near-Term Operations Validation of Acceptability (IM-NOVA) Experiment

    Science.gov (United States)

    Kibler, Jennifer L.; Wilson, Sara R.; Hubbs, Clay E.; Smail, James W.

    2015-01-01

    The Interval Management for Near-term Operations Validation of Acceptability (IM-NOVA) experiment was conducted at the National Aeronautics and Space Administration (NASA) Langley Research Center (LaRC) in support of the NASA Airspace Systems Program's Air Traffic Management Technology Demonstration-1 (ATD-1). ATD-1 is intended to showcase an integrated set of technologies that provide an efficient arrival solution for managing aircraft using Next Generation Air Transportation System (NextGen) surveillance, navigation, procedures, and automation for both airborne and ground-based systems. The goal of the IMNOVA experiment was to assess if procedures outlined by the ATD-1 Concept of Operations were acceptable to and feasible for use by flight crews in a voice communications environment when used with a minimum set of Flight Deck-based Interval Management (FIM) equipment and a prototype crew interface. To investigate an integrated arrival solution using ground-based air traffic control tools and aircraft Automatic Dependent Surveillance-Broadcast (ADS-B) tools, the LaRC FIM system and the Traffic Management Advisor with Terminal Metering and Controller Managed Spacing tools developed at the NASA Ames Research Center (ARC) were integrated into LaRC's Air Traffic Operations Laboratory (ATOL). Data were collected from 10 crews of current 757/767 pilots asked to fly a high-fidelity, fixed-based simulator during scenarios conducted within an airspace environment modeled on the Dallas-Fort Worth (DFW) Terminal Radar Approach Control area. The aircraft simulator was equipped with the Airborne Spacing for Terminal Area Routes (ASTAR) algorithm and a FIM crew interface consisting of electronic flight bags and ADS-B guidance displays. Researchers used "pseudo-pilot" stations to control 24 simulated aircraft that provided multiple air traffic flows into the DFW International Airport, and recently retired DFW air traffic controllers served as confederate Center, Feeder, Final

  20. Excess costs of social anxiety disorder in Germany.

    Science.gov (United States)

    Dams, Judith; König, Hans-Helmut; Bleibler, Florian; Hoyer, Jürgen; Wiltink, Jörg; Beutel, Manfred E; Salzer, Simone; Herpertz, Stephan; Willutzki, Ulrike; Strauß, Bernhard; Leibing, Eric; Leichsenring, Falk; Konnopka, Alexander

    2017-04-15

    Social anxiety disorder is one of the most frequent mental disorders. It is often associated with mental comorbidities and causes a high economic burden. The aim of our analysis was to estimate the excess costs of patients with social anxiety disorder compared to persons without anxiety disorder in Germany. Excess costs of social anxiety disorder were determined by comparing two data sets. Patient data came from the SOPHO-NET study A1 (n=495), whereas data of persons without anxiety disorder originated from a representative phone survey (n=3213) of the general German population. Missing data were handled by "Multiple Imputation by Chained Equations". Both data sets were matched using "Entropy Balancing". Excess costs were calculated from a societal perspective for the year 2014 using general linear regression with a gamma distribution and log-link function. Analyses considered direct costs (in- and outpatient treatment, rehabilitation, and professional and informal care) and indirect costs due to absenteeism from work. Total six-month excess costs amounted to 451€ (95% CI: 199€-703€). Excess costs were mainly caused by indirect excess costs due to absenteeism from work of 317€ (95% CI: 172€-461€), whereas direct excess costs amounted to 134€ (95% CI: 110€-159€). Costs for medication, unemployment and disability pension was not evaluated. Social anxiety disorder was associated with statistically significant excess costs, in particular due to indirect costs. As patients in general are often unaware of their disorder or its severity, awareness should be strengthened. Prevention and early treatment might reduce long-term indirect costs. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Automatic programmable air ozonizer

    International Nuclear Information System (INIS)

    Gubarev, S.P.; Klosovsky, A.V.; Opaleva, G.P.; Taran, V.S.; Zolototrubova, M.I.

    2015-01-01

    In this paper we describe a compact, economical, easy to manage auto air ozonator developed at the Institute of Plasma Physics of the NSC KIPT. It is designed for sanitation, disinfection of premises and cleaning the air from foreign odors. A distinctive feature of the developed device is the generation of a given concentration of ozone, approximately 0.7 maximum allowable concentration (MAC), and automatic maintenance of a specified level. This allows people to be inside the processed premises during operation. The microprocessor controller to control the operation of the ozonator was developed

  2. Emergency Air Rescue System in Romania

    Directory of Open Access Journals (Sweden)

    Tranca Sebastian

    2018-03-01

    Full Text Available The helicopter, as a means of transport, has facilitated a significant decrease in intervention time at the site of request, increasing the chances of survival of the critical patient. Since 2003, SMURD has managed to form a fleet composed of nine helicopters and two airplanes. From an operational and strategic point of view, the SMURD intervention unit, set up seven Aeromedical Operational Bases (A.O.B. equipped with helicopters and materials necessary for their operation. There is a dynamic increase in the number of air rescue missions in Romania, with most missions being carried out by the air rescue bases in Târgu Mureş and Bucharest. Specialty literature has clearly demonstrated the positive impact on the survival of critical patients assisted by airborne crews, so it is necessary for the Romanian air rescue system to grow up. It is necessary to increase the number of air bases, purchase new helicopters and to continue the training programs of both pilots and medical personnel.

  3. Operation of controlled-air incinerators and design considerations for controlled-air incinerators treating hazardous and radioactive wastes

    International Nuclear Information System (INIS)

    McRee, R.E.

    1986-01-01

    This paper reviews the basic theory and design philosophies of the so-called controlled-air incinerator and examines the features of this equipment that make it ideally suited to the application of low-level radioactive waste disposal. Special equipment design considerations for controlled air incinerators treating hazardous and radioactive wastes are presented. 9 figures

  4. Excess Volumes and Excess Isentropic Compressibilities of Binary Liquid Mixtures of Trichloroethylene with Esters at 303.15 K

    Science.gov (United States)

    Ramanaiah, S.; Rao, C. Narasimha; Nagaraja, P.; Venkateswarlu, P.

    2015-11-01

    Exces volumes, VE, and excess isentropic compressibilities, κSE, have been reported as a function of composition for binary liquid mixtures of trichloroethylene with ethyl acetate, n-propyl acetate, and n-butyl acetate at 303.15 K. Isentropic compressibilities are calculated using measured sound speeds and density data for pure components and for binary mixtures. Excess volumes and excess isentropic compressibilities are found to be negative for the three systems studied over the entire composition range at 303.15 K, whereas these values become more negative with an increase of carbon chain length. The results are discussed in terms of intermolecular interactions between unlike molecules.

  5. Energetics and dynamics of excess electrons in simple fluids

    International Nuclear Information System (INIS)

    Space, B.

    1992-01-01

    Excess electronic dynamical and equilibrium properties are modeled in both polarizable and nonpolarizable noble gas fluids. Explicit dynamical calculations are carried out for excess electrons in fluid helium, where excess electronic eigenstates are localized. Energetics and dynamics are considered for fluids which span the entire range of polarizability present in the rare gases. Excess electronic eigenstates and eigenvalues are calculated for fluids of helium, argon and xenon. Both equilibrium and dynamical information is obtained from the calculation of these wavefunctions. A surface hopping trajectory method for studying nonadiabatic excess electronic relaxation in condensed systems is used to explore the nonadiabatic relaxation after photoexciting an equilibrated excess electron in dense fluid helium. The different types on nonadiabatic phenomena which are important in excess electronic relaxation are surveyed. The same surface hopping trajectory method is also used to study the rapid nonadiabatic relaxation after an excess electron is injected into unperturbed fluid helium. Several distinctively different relaxation processes, characterized by their relative importance at different times during the relaxation to a localized equilibrium state, are detailed. Though the dynamical properties of excess electrons under the conditions considered here have never been studied before, the behavior is remarkably similar to that observed in both experimental and theoretical studies of electron hydration dynamics, indicating that the processes described may be very general relaxation mechanisms for localization and trapping in fluids. Additionally, ground state energies of an excess electron, e 0 , are computed as a function of solvent density using model electron-atom pseudopotentials in fluid helium, argon, and xenon. The nonuniqueness of the pseudopotential description of electron-molecule interactions is demonstrated

  6. Air operations language for military space ground systems

    Science.gov (United States)

    Davis, P.

    The trends in military space ground system architecture is toward large amounts of software and more widely distributed processors. At the same time, life cycle cost considerations dictate that fewer personnel with minimized skill levels and knowledge operate and support these systems. This squeeze necessitates more human engineering and operational planning into the design of these systems. Several techniques have been developed to satisfy these requirements. An operations language is one of these techniques. It involves a specially defined syntax for control of the system. Individual directives are able to be grouped into operations language procedures. These procedures can be prepared offline ahead of time by more skilled personnel and then used to ensure repeatability of operational sequences and reduce operator errors. The use of an operations language also provides benefits for the handling of contingency operations as well as in the system testing and validation programs.

  7. Measuring excess capital capacity in agricultural production

    NARCIS (Netherlands)

    Zhengfei, G.; Kumbhakar, S.C.; Myers, R.J.; Oude Lansink, A.G.J.M.

    2009-01-01

    We introduce the concept "excess capital capacity" and employ a stochastic input requirement frontier to measure excess capital capacity in agricultural production. We also propose a two-step estimation method that allows endogenous regressors in stochastic frontier models. The first step uses

  8. Columbia River final environmental impact statement. Appendix B: Air quality

    International Nuclear Information System (INIS)

    1995-11-01

    The System Operation Review (SOR) is a study and environmental compliance process being used by the three Federal agencies to analyze future operations of the system and river use issues. The goal of the SOR is to achieve a coordinated system operation strategy for the river that better meets the needs of all river users. This technical appendix addresses only the effects of alternative system operating strategies for managing the Columbia River system. This appendix consists of eight chapters. Chapter 1 describes the air quality issues that were raised in the SOR scoping process and provides an overview of the study process used to evaluate air quality effects from various system operation alternatives. Chapter 2 describes the Federal, state, and local programs that regulate air quality and discusses the air quality standards that are relevant to the analysis. It also gives an overview of the limatology of the region and the existing air quality in the Columbia River Basin, including areas of non-attainment for relevant air quality standards. Chapter 3 presents the methods this study uses for the analysis of air quality and for the evaluation of human health effects from air pollutants. Chapter 4 provides the study results for the System Operating Strategy (SOS) alternatives and potential mitigation measures. Chapter 5 compares impacts on air quality and human health across alternatives, and discusses mitigation measures and cumulative effects. Chapters 6, 7, and 8 contain the list of preparers, glossary, and references, respectively. Technical exhibits supporting the analysis are also included

  9. Improvements in or relating to devices for conducting excess heat away from heat sources

    International Nuclear Information System (INIS)

    Cooke-Yarborough, E.H.

    1976-01-01

    Reference is made to radioisotope powered heat engines. Should such an engine stop working for any reason the radioisotope heat source will continue to generate heat, and this may cause overheating and possible damage to the engine as well as the heat source. A device is described for conducting excess heat from the heat source to a heat sink but which in normal operation of the engine will impede heat conduction and so reduce thermal losses. The device may be used to support and/or locate the heat source. Constructional and operational details are given. (U.K.)

  10. Energy use, air infiltration, and indoor air quality in well-insulated residences

    International Nuclear Information System (INIS)

    Koontz, M.D.; Nagda, N.L.

    1989-01-01

    This paper reports two unoccupied bilevel houses of identical design and construction studied to determine the relationships among air exchange, energy consumption, and indoor air quality. The experimental house was retrofitted to increase building tightness and was equipped with an air-to-air heat exchanger; the control house was kept in its initial state of construction. Infiltration, energy, indoor air quality, and environmental parameters were monitored in both houses before and after the retrofit. It was found that the retrofit decreased air infiltration rates by nearly 25 percent, heating energy savings of 12 to 20 percent were achieved through the retrofit, and among the pollutants monitored, only radon and radon progeny increased in proportion to the reduced infiltration. Similarly, when the heat exchanger was operated, radon and radon progeny were the only pollutants reduced in proportion to the added air exchange

  11. CALCULATION OF AIR ION REGIME IN THE CASE OF ARTIFICIAL AIR IONIZATION

    Directory of Open Access Journals (Sweden)

    BILIAIEV M. M.

    2015-10-01

    Full Text Available Purpose. One of the major tasks in the field of labor protection is providing of the necessary qualitative composition of air in the working areas of office and industrial spaces. In order to maintain the necessary air ion level in the air space premises, the artificial ionization of air is used often in the premises. At present in Ukraine analytical model are used for the calculation of air ion regime in premises, influencing on the formation process of air ions concentration field. An alternative solution is the use of CFD models, developing including the air jets aerodynamics in the premise, the presence of furniture, equipment, transfer of ions under an electric field, and other physical factors, determining intensity and shape of air ions concentration field in the premise. Methodology. Influence of air flow was taken into account in the development of CFD models for calculation of air ion regime in the apartment, caused by operation of ventilation, diffusion, electric field impact, as well as the interaction of different polarity ions with each other, and their interaction with dust particles. The proposed model of calculation of air ion regime in premises based on the use of aerodynamics, electrostatics and mass transfer levels. This model allows operatively to calculate air ions concentration field with the influence of the walls, floor, ceiling and obstacles on the process of air ions dispersion, the specific location of different polarity ions emission and their interaction in the premise and work areas in conditions of artificial air ionization. Results. The calculated data were obtained and on their base could be estimated the concentration of air ion anywhere in the premise with artificial air ionization. Ions concentration field, being calculated using this CFD model, as concentration field isolines is presented. Originality. The results of the air ion regime calculation in the premise are presented, based on numerical 2D CFD model

  12. Balancing low cost with reliable operation in the rotordynamic design of the ALS Liquid Hydrogen Fuel Turbopump

    Science.gov (United States)

    Greenhill, L. M.

    1990-01-01

    The Air Force/NASA Advanced Launch System (ALS) Liquid Hydrogen Fuel Turbopump (FTP) has primary design goals of low cost and high reliability, with performance and weight having less importance. This approach is atypical compared with other rocket engine turbopump design efforts, such as on the Space Shuttle Main Engine (SSME), which emphasized high performance and low weight. Similar to the SSME turbopumps, the ALS FTP operates supercritically, which implies that stability and bearing loads strongly influence the design. In addition, the use of low cost/high reliability features in the ALS FTP such as hydrostatic bearings, relaxed seal clearances, and unshrouded turbine blades also have a negative influence on rotordynamics. This paper discusses the analysis conducted to achieve a balance between low cost and acceptable rotordynamic behavior, to ensure that the ALS FTP will operate reliably without subsynchronous instabilities or excessive bearing loads.

  13. Off-resonance frequency operation for power transfer in a loosely coupled air core transformer

    Science.gov (United States)

    Scudiere, Matthew B

    2012-11-13

    A power transmission system includes a loosely coupled air core transformer having a resonance frequency determined by a product of inductance and capacitance of a primary circuit including a primary coil. A secondary circuit is configured to have a substantially same product of inductance and capacitance. A back EMF generating device (e.g., a battery), which generates a back EMF with power transfer, is attached to the secondary circuit. Once the load power of the back EMF generating device exceeds a certain threshold level, which depends on the system parameters, the power transfer can be achieved at higher transfer efficiency if performed at an operating frequency less than the resonance frequency, which can be from 50% to 95% of the resonance frequency.

  14. Damage Control: Leveraging Crisis Communications for Operational Effect

    National Research Council Canada - National Science Library

    Gebara, Andrew J

    2008-01-01

    Despite the lopsided nature of contemporary air operations in combat against Islamo-fascism, the enemy has gained a measure of protection from air attack by savvy utilization of Information Operations...

  15. Toward Unity of Command for Multinational Air Forces

    National Research Council Canada - National Science Library

    Asjes, David

    1998-01-01

    To assure unity of command in future multinational air operations, combatant commanders must embrace the necessity of multinational air forces, maximize the integration of allied officers within air...

  16. Excessive crying in infants

    Directory of Open Access Journals (Sweden)

    Ricardo Halpern

    2016-05-01

    Full Text Available Objective: Review the literature on excessive crying in young infants, also known as infantile colic, and its effects on family dynamics, its pathophysiology, and new treatment interventions. Data source: The literature review was carried out in the Medline, PsycINFO, LILACS, SciELO, and Cochrane Library databases, using the terms “excessive crying,” and “infantile colic,” as well technical books and technical reports on child development, selecting the most relevant articles on the subject, with emphasis on recent literature published in the last five years. Summary of the findings: Excessive crying is a common symptom in the first 3 months of life and leads to approximately 20% of pediatric consultations. Different prevalence rates of excessive crying have been reported, ranging from 14% to approximately 30% in infants up to 3 months of age. There is evidence linking excessive crying early in life with adaptive problems in the preschool period, as well as with early weaning, maternal anxiety and depression, attention deficit hyperactivity disorder, and other behavioral problems. Several pathophysiological mechanisms can explain these symptoms, such as circadian rhythm alterations, central nervous system immaturity, and alterations in the intestinal microbiota. Several treatment alternatives have been described, including behavioral measures, manipulation techniques, use of medication, and acupuncture, with controversial results and effectiveness. Conclusion: Excessive crying in the early months is a prevalent symptom; the pediatrician's attention is necessary to understand and adequately manage the problem and offer support to exhausted parents. The prescription of drugs of questionable action and with potential side effects is not a recommended treatment, except in extreme situations. The effectiveness of dietary treatments and use of probiotics still require confirmation. There is incomplete evidence regarding alternative treatments

  17. Sanitary-epidemiological assessment of quality of atmospheric air in Moscow

    Directory of Open Access Journals (Sweden)

    E.E. Andreeva

    2016-12-01

    Full Text Available The results of the comparative assessment of the sanitary and epidemiological quality of the ambient air in Moscow and the Russian Federation, that demonstrate a decrease of the air pollution level in 2014 in comparison with 2012, both in Moscow and in the Russian Federation, are presented in this study. It has been noted that most of the excess of hygienic air quality standards in the areas of Russian cities are recorded on stationary observation stations situated close to the motorway, located in residential areas, and in Moscow – in the zones of industrial enterprises’ impact. It has been revealed that the tendency to the reduction of the negative impact from industrial enterprises on air pollution is registered in the whole of the Russian Federation and in Moscow. It is demonstrated that the high-priority contaminating agents, the content of which for the year 2014 in the Russian Federation exceeded the hygienic daily average standards in 5 and more times, are mainly: benzo (a pyrene, suspended substances, sulfur dioxide, benzene, formaldehyde, nitrogen dioxide, hydrogen sulfide, etc. To assess the quality of the ambient air in Moscow, the method of "inverse distance" and inter- and extrapolation of the data obtained from the observation stations on the whole territory of Moscow has been used. The study shows that the air quality of the individual administrative districts of Moscow varies considerably, and is determined by the traffic load level as well as by the volume of emissions of the industrial enterprises and the wind rose. As high-priority contaminating agents affecting the air quality, nitrogen dioxide, ammonia, benzene, suspended substances, ozone and formaldehyde are distinguished. It is noted that close to the highway near Moscow there is an excessive concentration of nitrogen dioxide, formaldehyde, phenol, and carbon monoxide, and in areas close to industrial zones – nitrogen dioxide, phenol formaldehyde and benzo (a

  18. 14 CFR 375.50 - Transit flights; scheduled international air service operations.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Transit flights; scheduled international... WITHIN THE UNITED STATES Transit Flights § 375.50 Transit flights; scheduled international air service... to the International Air Services Transit Agreement in transit across the United States may not be...

  19. The excessively crying infant : etiology and treatment

    NARCIS (Netherlands)

    Akhnikh, S.; Engelberts, A.C.; Sleuwen, B.E. van; Hoir, M.P. L’; Benninga, M.A.

    2014-01-01

    Excessive crying, often described as infantile colic, is the cause of 10% to 20% of all early pediatrician visits of infants aged 2 weeks to 3 months. Although usually benign and selflimiting, excessive crying is associated with parental exhaustion and stress. However, and underlying organic cause

  20. Simple Models for Airport Delays During Transition to a Trajectory-Based Air Traffic System

    Science.gov (United States)

    Brooker, Peter

    It is now widely recognised that a paradigm shift in air traffic control concepts is needed. This requires state-of-the-art innovative technologies, making much better use of the information in the air traffic management (ATM) system. These paradigm shifts go under the names of NextGen in the USA and SESAR in Europe, which inter alia will make dramatic changes to the nature of airport operations. A vital part of moving from an existing system to a new paradigm is the operational implications of the transition process. There would be business incentives for early aircraft fitment, it is generally safer to introduce new technologies gradually, and researchers are already proposing potential transition steps to the new system. Simple queuing theory models are used to establish rough quantitative estimates of the impact of the transition to a more efficient time-based navigational and ATM system. Such models are approximate, but they do offer insight into the broad implications of system change and its significant features. 4D-equipped aircraft in essence have a contract with the airport runway and, in return, they would get priority over any other aircraft waiting for use of the runway. The main operational feature examined here is the queuing delays affecting non-4D-equipped arrivals. These get a reasonable service if the proportion of 4D-equipped aircraft is low, but this can deteriorate markedly for high proportions, and be economically unviable. Preventative measures would be to limit the additional growth of 4D-equipped flights and/or to modify their contracts to provide sufficient space for the non-4D-equipped flights to operate without excessive delays. There is a potential for non-Poisson models, for which there is little in the literature, and for more complex models, e.g. grouping a succession of 4D-equipped aircraft as a batch.