WorldWideScience

Sample records for event-related single-shot volumetric

  1. Single-Shot, Volumetrically Illuminated, Three-Dimensional, Tomographic Laser-Induced-Fluorescence Imaging in a Gaseous Free Jet

    Science.gov (United States)

    2016-04-28

    Single-shot, volumetrically illuminated, three- dimensional, tomographic laser-induced- fluorescence imaging in a gaseous free jet Benjamin R. Halls...acquisition; (110.6955) Tomographic imaging ; (110.6960) Tomography; (280.2490) Flow diagnostics; (300.2530) Fluorescence , laser-induced...84 (1983). 2. I. van Cruyningen, A. Lozano, and R. K. Hanson, “Quantitative imaging of concentration by planar laser-induced fluorescence ,” Exp

  2. The single-shot opto-digitizer

    International Nuclear Information System (INIS)

    Nail, M.; Gibert, Ph.

    2000-01-01

    Laser-plasma experiments need to measure signals provided either by X-ray, photonic or neutronic detector. The measurement should have 50 GHz bandwidth and up to several hundred of Giga-Hertz for sub picosecond plasmas. For this purpose, a 35 GHz single shot opto-digitizer (10 ps risetime) has been studied and built. The device is made up of a 50 ohms microstrip propagation line, periodically lined by 100 sampled gates. The propagation line is long enough to measure a 400 ps duration. The sampling rate is 250 Gsa/s (every 4 ps). The sampled gates are made with fast recombining photo-material and turn on by a subpicosecond laser pulse which is synchronized exactly with the analysed phenomena. Every gate is recording to a storing capacitor. After the recording, every capacitor charge is needed to built the signal that was displayed on the propagation line. The dynamic range of measurement is 47 for the entire device. The device can measure positive or negative signals from 1.5 to 70 Volts. To increase the bandwidth, two another kinds of opto-digitizer were studied: one is a buried stripline with 56 GHz band width, the other a 70 GHz coplanar transmission line. For the purpose of subpicosecond plasmas, a 30 coplanar waveguide opto-digitizer was studied. Characteristics are as followed: window of measurement 40 ps, sampling rate 1 ps, bandwidth 230 GHz. Finally, a bundle of optical fibers was used to propagate the laser beam on semiconductor gates. If the gates are lighted at the same time, i.e. if the optical fibers have the same length, we get a simultaneous addressing. By using different lengths of optical fibers, we can do a sequential addressing. So, the sampling rate becomes a combination of the distance between two adjacent sampled channels, and the difference in length of optical fibers. (author)

  3. Single-shot measurement of nonlinear absorption and nonlinear refraction.

    Science.gov (United States)

    Jayabalan, J; Singh, Asha; Oak, Shrikant M

    2006-06-01

    A single-shot method for measurement of nonlinear optical absorption and refraction is described and analyzed. A spatial intensity variation of an elliptical Gaussian beam in conjugation with an array detector is the key element of this method. The advantages of this single-shot technique were demonstrated by measuring the two-photon absorption and free-carrier absorption in GaAs as well as the nonlinear refractive index of CS2 using a modified optical Kerr setup.

  4. Single-shot spiral imaging at 7 T.

    Science.gov (United States)

    Engel, Maria; Kasper, Lars; Barmet, Christoph; Schmid, Thomas; Vionnet, Laetitia; Wilm, Bertram; Pruessmann, Klaas P

    2018-03-25

    The purpose of this work is to explore the feasibility and performance of single-shot spiral MRI at 7 T, using an expanded signal model for reconstruction. Gradient-echo brain imaging is performed on a 7 T system using high-resolution single-shot spiral readouts and half-shot spirals that perform dual-image acquisition after a single excitation. Image reconstruction is based on an expanded signal model including the encoding effects of coil sensitivity, static off-resonance, and magnetic field dynamics. The latter are recorded concurrently with image acquisition, using NMR field probes. The resulting image resolution is assessed by point spread function analysis. Single-shot spiral imaging is achieved at a nominal resolution of 0.8 mm, using spiral-out readouts of 53-ms duration. High depiction fidelity is achieved without conspicuous blurring or distortion. Effective resolutions are assessed as 0.8, 0.94, and 0.98 mm in CSF, gray matter and white matter, respectively. High image quality is also achieved with half-shot acquisition yielding image pairs at 1.5-mm resolution. Use of an expanded signal model enables single-shot spiral imaging at 7 T with unprecedented image quality. Single-shot and half-shot spiral readouts deploy the sensitivity benefit of high field for rapid high-resolution imaging, particularly for functional MRI and arterial spin labeling. © 2018 International Society for Magnetic Resonance in Medicine.

  5. Single-shot positron annihilation lifetime spectroscopy with LYSO scintillators

    Science.gov (United States)

    Alonso, A. M.; Cooper, B. S.; Deller, A.; Cassidy, D. B.

    2016-08-01

    We have evaluated the application of a lutetium yttrium oxyorthosilicate (LYSO) based detector to single-shot positron annihilation lifetime spectroscopy. We compare this detector directly with a similarly configured PbWO4 scintillator, which is the usual choice for such measurements. We find that the signal to noise ratio obtained using LYSO is around three times higher than that obtained using PbWO4 for measurements of Ps excited to longer-lived (Rydberg) levels, or when they are ionized soon after production. This is due to the much higher light output for LYSO (75% and 1% of NaI for LYSO and PbWO4 respectively). We conclude that LYSO is an ideal scintillator for single-shot measurements of positronium production and excitation performed using a low-intensity pulsed positron beam.

  6. Single-shot positron annihilation lifetime spectroscopy with LYSO scintillators

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, A.M., E-mail: a.alonso@ucl.ac.uk; Cooper, B.S.; Deller, A.; Cassidy, D.B.

    2016-08-21

    We have evaluated the application of a lutetium yttrium oxyorthosilicate (LYSO) based detector to single-shot positron annihilation lifetime spectroscopy. We compare this detector directly with a similarly configured PbWO{sub 4} scintillator, which is the usual choice for such measurements. We find that the signal to noise ratio obtained using LYSO is around three times higher than that obtained using PbWO{sub 4} for measurements of Ps excited to longer-lived (Rydberg) levels, or when they are ionized soon after production. This is due to the much higher light output for LYSO (75% and 1% of NaI for LYSO and PbWO{sub 4} respectively). We conclude that LYSO is an ideal scintillator for single-shot measurements of positronium production and excitation performed using a low-intensity pulsed positron beam.

  7. Single-shot positron annihilation lifetime spectroscopy with LYSO scintillators

    OpenAIRE

    Alonso, A. M.; Cooper, B. S.; Deller, A.; Cassidy, D. B.

    2016-01-01

    We have evaluated the application of a lutetium yttrium oxyorthosilicate (LYSO) based detector to single-shot positron annihilation lifetime spectroscopy. We compare this detector directly with a similarly configured PbWO4 scintillator, which is the usual choice for such measurements. We find that the signal to noise ratio obtained using LYSO is around three times higher than that obtained using PbWO4 for measurements of Ps excited to longer-lived (Rydberg) levels, or when they are ionized so...

  8. Single-shot 35 fs temporal resolution electron shadowgraphy

    Energy Technology Data Exchange (ETDEWEB)

    Scoby, C. M.; Li, R. K.; Threlkeld, E.; To, H.; Musumeci, P. [Department of Physics and Astronomy, UCLA, Los Angeles, California 90095 (United States)

    2013-01-14

    We obtain single-shot time-resolved shadowgraph images of the electromagnetic fields resulting from the interaction of a high intensity ultrashort laser pulse with a metal surface. Using a high brightness relativistic electron beam and a high streaking speed radiofrequency deflector, we report <35 fs temporal resolution enabling a direct visualization of the retarded-time dominated field evolution which follows the laser-induced charge emission. A model including the finite signal propagation speed well reproduces the data and yields measurements of fundamental parameters in short pulse laser-matter interaction such as the amount of emitted charge and the emission time scale.

  9. Single-shot 35 fs temporal resolution electron shadowgraphy

    International Nuclear Information System (INIS)

    Scoby, C. M.; Li, R. K.; Threlkeld, E.; To, H.; Musumeci, P.

    2013-01-01

    We obtain single-shot time-resolved shadowgraph images of the electromagnetic fields resulting from the interaction of a high intensity ultrashort laser pulse with a metal surface. Using a high brightness relativistic electron beam and a high streaking speed radiofrequency deflector, we report <35 fs temporal resolution enabling a direct visualization of the retarded-time dominated field evolution which follows the laser-induced charge emission. A model including the finite signal propagation speed well reproduces the data and yields measurements of fundamental parameters in short pulse laser-matter interaction such as the amount of emitted charge and the emission time scale.

  10. Single-Shot MR Spectroscopic Imaging with Partial Parallel Imaging

    Science.gov (United States)

    Posse, Stefan; Otazo, Ricardo; Tsai, Shang-Yueh; Yoshimoto, Akio Ernesto; Lin, Fa-Hsuan

    2010-01-01

    An MR spectroscopic imaging (MRSI) pulse sequence based on Proton-Echo-Planar-Spectroscopic-Imaging (PEPSI) is introduced that measures 2-dimensional metabolite maps in a single excitation. Echo-planar spatial-spectral encoding was combined with interleaved phase encoding and parallel imaging using SENSE to reconstruct absorption mode spectra. The symmetrical k-space trajectory compensates phase errors due to convolution of spatial and spectral encoding. Single-shot MRSI at short TE was evaluated in phantoms and in vivo on a 3 T whole body scanner equipped with 12-channel array coil. Four-step interleaved phase encoding and 4-fold SENSE acceleration were used to encode a 16×16 spatial matrix with 390 Hz spectral width. Comparison with conventional PEPSI and PEPSI with 4-fold SENSE acceleration demonstrated comparable sensitivity per unit time when taking into account g-factor related noise increases and differences in sampling efficiency. LCModel fitting enabled quantification of Inositol, Choline, Creatine and NAA in vivo with concentration values in the ranges measured with conventional PEPSI and SENSE-accelerated PEPSI. Cramer-Rao lower bounds were comparable to those obtained with conventional SENSE-accelerated PEPSI at the same voxel size and measurement time. This single-shot MRSI method is therefore suitable for applications that require high temporal resolution to monitor temporal dynamics or to reduce sensitivity to tissue movement. PMID:19097245

  11. Single-shot polarimetry imaging of multicore fiber.

    Science.gov (United States)

    Sivankutty, Siddharth; Andresen, Esben Ravn; Bouwmans, Géraud; Brown, Thomas G; Alonso, Miguel A; Rigneault, Hervé

    2016-05-01

    We report an experimental test of single-shot polarimetry applied to the problem of real-time monitoring of the output polarization states in each core within a multicore fiber bundle. The technique uses a stress-engineered optical element, together with an analyzer, and provides a point spread function whose shape unambiguously reveals the polarization state of a point source. We implement this technique to monitor, simultaneously and in real time, the output polarization states of up to 180 single-mode fiber cores in both conventional and polarization-maintaining fiber bundles. We demonstrate also that the technique can be used to fully characterize the polarization properties of each individual fiber core, including eigen-polarization states, phase delay, and diattenuation.

  12. Ship Detection Using Transfer Learned Single Shot Multi Box Detector

    Directory of Open Access Journals (Sweden)

    Nie Gu-Hong

    2017-01-01

    Full Text Available Ship detection in satellite images is a challenging task. In this paper, we introduce a transfer learned Single Shot MultiBox Detector (SSD for ship detection. To this end, a state-of-the-art object detection model pre-trained from a large number of natural images was transfer learned for ship detection with limited labeled satellite images. To the best of our knowledge, this could be one of the first studies which introduce SSD into ship detection on satellite images. Experiments demonstrated that our method could achieve 87.9% AP at 47 FPS using NVIDIA TITAN X. In comparison with Faster R-CNN, 6.7% AP improvement could be achieved. Effects of the observation resolution has also been studied with the changing input sizes among 300 × 300, 600 × 600 and 900 × 900. It has been noted that the detection accuracy declined sharply with the decreasing resolution that is mainly caused by the missing small ships.

  13. Time-resolved single-shot terahertz time-domain spectroscopy for ultrafast irreversible processes

    Science.gov (United States)

    Zhai, Zhao-Hui; Zhong, Sen-Cheng; Li, Jun; Zhu, Li-Guo; Meng, Kun; Li, Jiang; Liu, Qiao; Peng, Qi-Xian; Li, Ze-Ren; Zhao, Jian-Heng

    2016-09-01

    Pulsed terahertz spectroscopy is suitable for spectroscopic diagnostics of ultrafast events. However, the study of irreversible or single shot ultrafast events requires ability to record transient properties at multiple time delays, i.e., time resolved at single shot level, which is not available currently. Here by angular multiplexing use of femtosecond laser pulses, we developed and demonstrated a time resolved, transient terahertz time domain spectroscopy technique, where burst mode THz pulses were generated and then detected in a single shot measurement manner. The burst mode THz pulses contain 2 sub-THz pulses, and the time gap between them is adjustable up to 1 ns with picosecond accuracy, thus it can be used to probe the single shot event at two different time delays. The system can detect the sub-THz pulses at 0.1 THz-2.5 THz range with signal to noise ratio (SNR) of ˜400 and spectrum resolution of 0.05 THz. System design was described here, and optimizations of single shot measurement of THz pulses were discussed in detail. Methods to improve SNR were also discussed in detail. A system application was demonstrated where pulsed THz signals at different time delays of the ultrafast process were successfully acquired within single shot measurement. This time resolved transient terahertz time domain spectroscopy technique provides a new diagnostic tool for irreversible or single shot ultrafast events where dynamic information can be extracted at terahertz range within one-shot experiment.

  14. High-Fidelity Single-Shot Toffoli Gate via Quantum Control.

    Science.gov (United States)

    Zahedinejad, Ehsan; Ghosh, Joydip; Sanders, Barry C

    2015-05-22

    A single-shot Toffoli, or controlled-controlled-not, gate is desirable for classical and quantum information processing. The Toffoli gate alone is universal for reversible computing and, accompanied by the Hadamard gate, forms a universal gate set for quantum computing. The Toffoli gate is also a key ingredient for (nontopological) quantum error correction. Currently Toffoli gates are achieved by decomposing into sequentially implemented single- and two-qubit gates, which require much longer times and yields lower overall fidelities compared to a single-shot implementation. We develop a quantum-control procedure to construct a single-shot Toffoli gate for three nearest-neighbor-coupled superconducting transmon systems such that the fidelity is 99.9% and is as fast as an entangling two-qubit gate under the same realistic conditions. The gate is achieved by a nongreedy quantum control procedure using our enhanced version of the differential evolution algorithm.

  15. Single-Shot Spectrometry for X-Ray Free-Electron Lasers

    International Nuclear Information System (INIS)

    Yabashi, Makina; Ishikawa, Tetsuya; Hastings, Jerome B.; Zolotorev, Max S.; Mimura, Hidekazu; Yumoto, Hirokatsu; Matsuyama, Satoshi; Yamauchi, Kazuto

    2006-01-01

    An experimental scheme to realize single-shot spectrometry for the diagnostics of x-ray free-electron lasers (XFELs) is presented. The combination of an ultraprecisely figured mirror and a perfect crystal form a simple, high-precision spectrometer that can cover an energy range from a few eV to a hundred eV with high resolution. The application of the spectrometer to determine XFEL pulse widths was investigated theoretically and experimentally. It has been shown that the present system can determine pulse widths from sub-fs to ps in a single shot even for spontaneous radiation. The system can be easily extended to even shorter pulses

  16. Single-shot self-interference incoherent digital holography using off-axis configuration.

    Science.gov (United States)

    Hong, Jisoo; Kim, Myung K

    2013-12-01

    We propose a single-shot incoherent holographic imaging technique that adopts self-interference incoherent digital holography (SIDH) with slight tilt of the plane mirror in the optical configuration. The limited temporal coherence length of the illumination leads the guide-star hologram of the proposed system to have a Gaussian envelope of elliptical ring shape. The observation shows that the reconstruction by cross correlation with the guide-star hologram achieves better quality than the usual propagation methods. Experimentally, we verify that the hologram and 3D reconstruction can be implemented incoherently with the proposed single-shot off-axis SIDH.

  17. Single-shot LIBS spectral quality for waste particles in open air

    NARCIS (Netherlands)

    Xia, H.; Bakker, M.C.M.

    2015-01-01

    This work investigates the ability of LIBS to produce quality spectra from small particles of concrete demolition waste using single-shot spectra collected in open air. The 2–8?mm materials are rounded river gravel, green glass shards, and plastic flakes. Considered are focal length, air, moisture,

  18. Single-shot spiral imaging enabled by an expanded encoding model: Demonstration in diffusion MRI.

    Science.gov (United States)

    Wilm, Bertram J; Barmet, Christoph; Gross, Simon; Kasper, Lars; Vannesjo, S Johanna; Haeberlin, Max; Dietrich, Benjamin E; Brunner, David O; Schmid, Thomas; Pruessmann, Klaas P

    2017-01-01

    The purpose of this work was to improve the quality of single-shot spiral MRI and demonstrate its application for diffusion-weighted imaging. Image formation is based on an expanded encoding model that accounts for dynamic magnetic fields up to third order in space, nonuniform static B 0 , and coil sensitivity encoding. The encoding model is determined by B 0 mapping, sensitivity mapping, and concurrent field monitoring. Reconstruction is performed by iterative inversion of the expanded signal equations. Diffusion-tensor imaging with single-shot spiral readouts is performed in a phantom and in vivo, using a clinical 3T instrument. Image quality is assessed in terms of artefact levels, image congruence, and the influence of the different encoding factors. Using the full encoding model, diffusion-weighted single-shot spiral imaging of high quality is accomplished both in vitro and in vivo. Accounting for actual field dynamics, including higher orders, is found to be critical to suppress blurring, aliasing, and distortion. Enhanced image congruence permitted data fusion and diffusion tensor analysis without coregistration. Use of an expanded signal model largely overcomes the traditional vulnerability of spiral imaging with long readouts. It renders single-shot spirals competitive with echo-planar readouts and thus deploys shorter echo times and superior readout efficiency for diffusion imaging and further prospective applications. Magn Reson Med 77:83-91, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  19. In vivo single-shot (13)C spectroscopic imaging of hyperpolarized metabolites by spatiotemporal encoding

    DEFF Research Database (Denmark)

    Schmidt, Rita; Laustsen, Christoffer; Dumez, Jean-Nicolas

    2014-01-01

    are necessary. Several approaches have been customized for hyperpolarized (13)C MRI, including CSI with a center-out k-space encoding, EPSI, and spectrally selective pulses in combination with spiral EPI acquisitions. Recent studies have described the potential of single-shot alternatives based...... temporal) data sets were obtained at 7T from a murine lymphoma tumor model....

  20. Comparative Study on the Efficacy of Two Regimens of Single-Shot ...

    African Journals Online (AJOL)

    Objective: To assess and compare the satisfaction and efficacy of two regimens of single-shot spinal blocks for the relief of labor pain in women who present in active phase of labour. Design: A prospective randomised single-blind observational study. Setting: Labour ward of Kenyatta National Hospital, Nairobi. Subjects: All ...

  1. From single-shot towards general work extraction in a quantum thermodynamic framework

    International Nuclear Information System (INIS)

    Gemmer, Jochen; Anders, Janet

    2015-01-01

    This paper considers work extraction from a quantum system to a work storage system (or weight) following Horodecki and Oppenheim (2013 Nat. Commun. 4 2059). An alternative approach is here developed that relies on the comparison of subspace dimensions without a need to introduce thermo-majorization used previously. Optimal single shot work for processes where a weight transfers from (a) a single energy level to another single energy level is then re-derived. In addition we discuss the final state of the system after work extraction and show that the system typically ends in its thermal state, while there are cases where the system is only close to it. The work of formation in the single level transfer setting is also re-derived. The approach presented now allows the extension of the single shot work concept to work extraction (b) involving multiple final levels of the weight. A key conclusion here is that the single shot work for case (a) is appropriate only when a resonance of a particular energy is required. When wishing to identify ‘work extraction’ with finding the weight in a specific available energy or any higher energy a broadening of the single shot work concept is required. As a final contribution we consider transformations of the system that (c) result in general weight state transfers. Introducing a transfer-quantity allows us to formulate minimum requirements for transformations to be at all possible in a thermodynamic framework. We show that choosing the free energy difference of the weight as the transfer-quantity one recovers various single shot results including single level transitions (a), multiple final level transitions (b), and recent results on restricted sets of multi-level to multi-level weight transfers. (paper)

  2. Single-shot readout of accumulation mode Si/SiGe spin qubits using RF reflectometry

    Science.gov (United States)

    Volk, Christian; Martins, Frederico; Malinowski, Filip; Marcus, Charles M.; Kuemmeth, Ferdinand

    Spin qubits based on gate-defined quantum dots are promising systems for realizing quantum computation. Due to their low concentration of nuclear-spin-carrying isotopes, Si/SiGe heterostructures are of particular interest. While high fidelities have been reported for single-qubit and two-qubit gate operations, qubit initialization and measurement times are relatively slow. In order to develop fast read-out techniques compatible with the operation of spin qubits, we characterize double and triple quantum dots confined in undoped Si/Si0.7Ge0.3 heterostructures using accumulation and depletion gates and a nearby RF charge sensor dot. We implement a RF reflectometry technique that allows single-shot charge read-out at integration times on the order of a few μs. We show our recent advancement towards implementing spin qubits in these structures, including spin-selective single-shot read-out.

  3. Algorithms for image recovery calculation in extended single-shot phase-shifting digital holography

    Science.gov (United States)

    Hasegawa, Shin-ya; Hirata, Ryo

    2018-04-01

    The single-shot phase-shifting method of image recovery using an inclined reference wave has the advantages of reducing the effects of vibration, being capable of operating in real time, and affording low-cost sensing. In this method, relatively low reference angles compared with that in the conventional method using phase shift between three or four pixels has been required. We propose an extended single-shot phase-shifting technique which uses the multiple-step phase-shifting algorithm and the corresponding multiple pixels which are the same as that of the period of an interference fringe. We have verified the theory underlying this recovery method by means of Fourier spectral analysis and its effectiveness by evaluating the visibility of the image using a high-resolution pattern. Finally, we have demonstrated high-contrast image recovery experimentally using a resolution chart. This method can be used in a variety of applications such as color holographic interferometry.

  4. Single-shot and single-spot measurement of laser ablation threshold for carbon nanotubes

    OpenAIRE

    Lednev, Vasily N.; Pershin, Sergey M.; Obraztsova, Elena D.; Kudryashov, Sergey I.; Bunkin, Alexey F.

    2013-01-01

    A simple and convenient procedure for single-shot, single-spot ablation threshold measurement has been developed. It is based on the employment of cylindrical lens to obtain elliptical Gaussian laser spot. The ablated spot chords which are parallel to the minor axis were measured across the spot major axis which is proportional to the fluence cross-section thus providing wide range dependence of damaged spot size versus fluence in one spot measurement. For both conventional and new-developed ...

  5. Infrared single shot diagnostics for the longitudinal profile of the electron bunches at FLASH

    International Nuclear Information System (INIS)

    Delsim-Hashemi, Hossein

    2008-09-01

    The longitudinal profile of electron bunches plays an important role in the design of single-pass free electron lasers and future linear e + e - colliders. For the free electron laser FLASH in Hamburg, a longitudinal compression scheme is used which results in an asymmetric longitudinal bunch profile with a 'spike'. This 'spike', which has a very high peak current, is used in a high-gain SASE-FEL process to produce high intensity (about 70 μJ) femtosecond photon pulses in the XUV wavelength range. The required high peak current of the electron bunch is realized by confining a large number of electrons in a width, measured in time units, of few tens of femtosecond, making the diagnostics of such bunches a challenge. Furthermore, the operation of facilities such as FLASH shows that single-shot diagnostics is indispensable. It is intuitive to use a time domain method to measure the electron bunch length. However, when the structures present in the bunch profile fall in the femtoseconds range, this is beyond the resolution of time-resolved methods developed so far. In this thesis, a wavelength-domain technique is described that can fulfill both requirements of single shot and high resolution reaching to the femtoseconds range. The amount of charge that is confined in a typical length of several femtoseconds (FWHM of the spike) can be determined by a novel single-shot spectrometer that resolves the coherent radiation (e.g. coherent transition radiation) in the far-infrared and mid-infrared range. Furthermore the extension of this single-shot spectroscopy to shorter wavelengths reaching the near-infrared, makes it possible to investigate the presence of structures in the bunch profile that might correlate or anti-correlate to the SASE intensity. (orig.)

  6. Single-shot speckle reduction in numerical reconstruction of digitally recorded holograms.

    Science.gov (United States)

    Hincapie, Diego; Herrera-Ramírez, Jorge; Garcia-Sucerquia, Jorge

    2015-04-15

    A single-shot method to reduce the speckle noise in the numerical reconstructions of electronically recorded holograms is presented. A recorded hologram with the dimensions N×M is split into S=T×T sub-holograms. The uncorrelated superposition of the individually reconstructed sub-holograms leads to an image with the speckle noise reduced proportionally to the 1/S law. The experimental results are presented to support the proposed methodology.

  7. Infrared single shot diagnostics for the longitudinal profile of the electron bunches at FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Delsim-Hashemi, Hossein

    2008-09-15

    The longitudinal profile of electron bunches plays an important role in the design of single-pass free electron lasers and future linear e{sup +}e{sup -} colliders. For the free electron laser FLASH in Hamburg, a longitudinal compression scheme is used which results in an asymmetric longitudinal bunch profile with a 'spike'. This 'spike', which has a very high peak current, is used in a high-gain SASE-FEL process to produce high intensity (about 70 {mu}J) femtosecond photon pulses in the XUV wavelength range. The required high peak current of the electron bunch is realized by confining a large number of electrons in a width, measured in time units, of few tens of femtosecond, making the diagnostics of such bunches a challenge. Furthermore, the operation of facilities such as FLASH shows that single-shot diagnostics is indispensable. It is intuitive to use a time domain method to measure the electron bunch length. However, when the structures present in the bunch profile fall in the femtoseconds range, this is beyond the resolution of time-resolved methods developed so far. In this thesis, a wavelength-domain technique is described that can fulfill both requirements of single shot and high resolution reaching to the femtoseconds range. The amount of charge that is confined in a typical length of several femtoseconds (FWHM of the spike) can be determined by a novel single-shot spectrometer that resolves the coherent radiation (e.g. coherent transition radiation) in the far-infrared and mid-infrared range. Furthermore the extension of this single-shot spectroscopy to shorter wavelengths reaching the near-infrared, makes it possible to investigate the presence of structures in the bunch profile that might correlate or anti-correlate to the SASE intensity. (orig.)

  8. Single shot diffraction of picosecond 8.7-keV x-ray pulses

    Directory of Open Access Journals (Sweden)

    F. H. O’Shea

    2012-02-01

    Full Text Available We demonstrate multiphoton, single shot diffraction images of x rays produced by inverse Compton scattering a high-power CO_{2} laser from a relativistic electron beam, creating a pulse of 8.7 keV x rays. The tightly focused, relatively high peak brightness electron beam and high photon density from the 2 J CO_{2} laser yielded 6×10^{7} x-ray photons over the full opening angle in a single shot. Single shot x-ray diffraction is performed by passing the x rays though a vertical slit and on to a flat silicon (111 crystal. 10^{2} diffracted photons were detected. The spectrum of the detected x rays is compared to simulation. The diffraction and detection of 10^{2} x rays is a key step to a more efficient time resolved diagnostic in which the number of observed x rays might reach 10^{4}; enabling a unique, flexible x-ray source as a sub-ps resolution diagnostic for studying the evolution of chemical reactions, lattice deformation and melting, and magnetism.

  9. Single-shot echo-planar imaging of multiple sclerosis: effects of varying echo time

    International Nuclear Information System (INIS)

    Wolansky, L.J.; Chong, S.; Liu, W.C.; Kang, E.; Simpson, S.W.; Karimi, S.; Akbari, H.

    1999-01-01

    Our aim was to determine the relative merits of short and long echo times (TE) with single-shot echo-planar imaging for imaging cerebral lesions such as multiple sclerosis. We examined seven patients with clinically definite multiple sclerosis were imaged at 1.5 T. Patients were scanned with spin-echo, single-shot echo-planar imaging, using TEs of 45, 75, 105, and 135 ms. Region of interest (ROI) measurements were performed on 36 lesions at or above the level of the corona radiata. The mean image contrast (IC) was highest (231.1) for a TE of 45 ms, followed by 75 ms (218.9), 105 ms (217.9), and 135 ms (191.6). When mean contrast-to-noise ratios (C/N) were compared, the value was again highest (29.7) for TE 45 ms, followed by 75 ms (28.9), 105 ms (28.5), and 135 ms (26.3). In a lesion-by-lesion comparison, TE 45 ms had the highest IC and C/N in the largest number of cases (50 % and 47.2 %, respectively). IC and C/N for TE 45 ms were superior to those of 75 ms in 64 % and 58 %, respectively. These results support the use of relatively short TEs for single-shot echo-planar imaging in the setting of cerebral lesions such as multiple sclerosis. (orig.) (orig.)

  10. Partial Fourier techniques in single-shot cross-term spatiotemporal encoded MRI.

    Science.gov (United States)

    Zhang, Zhiyong; Frydman, Lucio

    2018-03-01

    Cross-term spatiotemporal encoding (xSPEN) is a single-shot approach with exceptional immunity to field heterogeneities, the images of which faithfully deliver 2D spatial distributions without requiring a priori information or using postacquisition corrections. xSPEN, however, suffers from signal-to-noise ratio penalties due to its non-Fourier nature and due to diffusion losses-especially when seeking high resolution. This study explores partial Fourier transform approaches that, acting along either the readout or the spatiotemporally encoded dimensions, reduce these penalties. xSPEN uses an orthogonal (e.g., z) gradient to read, in direct space, the low-bandwidth (e.g., y) dimension. This substantially changes the nature of partial Fourier acquisitions vis-à-vis conventional imaging counterparts. A suitable theoretical analysis is derived to implement these procedures, along either the spatiotemporally or readout axes. Partial Fourier single-shot xSPEN images were recorded on preclinical and human scanners. Owing to their reduction in the experiments' acquisition times, this approach provided substantial sensitivity gains vis-à-vis previous implementations for a given targeted in-plane resolution. The physical origins of these gains are explained. Partial Fourier approaches, particularly when implemented along the low-bandwidth spatiotemporal dimension, provide several-fold sensitivity advantages at minimal costs to the execution and processing of the single-shot experiments. Magn Reson Med 79:1506-1514, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  11. Ultrafast bold fMRI using single-shot spin-echo echo planar imaging

    Directory of Open Access Journals (Sweden)

    Boujraf Said

    2009-01-01

    Full Text Available The choice of imaging parameters for functional MRI can have an impact on the accuracy of functional localization by affecting the image quality and the degree of blood oxygenation-dependent (BOLD contrast achieved. By improving sampling efficiency, parallel acquisition techniques such as sensitivity encoding (SENSE have been used to shorten readout trains in single-shot (SS echo planar imaging (EPI. This has been applied to susceptibility artifact reduction and improving spatial resolution. SENSE together with single-shot spin-echo (SS-SE imaging may also reduce off-resonance artifacts. The goal of this work was to investigate the BOLD response of a SENSE-adapted SE-EPI on a three Tesla scanner. Whole-brain fMRI studies of seven healthy right hand-dominant volunteers were carried out in a three Tesla scanner. fMRI was performed using an SS-SE EPI sequence with SENSE. The data was processed using statistical parametric mapping. Both, group and individual subject data analyses were performed. Individual average percentage and maximal percentage signal changes attributed to the BOLD effect in M1 were calculated for all the subjects as a function of echo time. Corresponding activation maps and the sizes of the activated clusters were also calculated. Our results show that susceptibility artifacts were reduced with the use of SENSE; and the acquired BOLD images were free of the typical quadrature artifacts of SS-EPI. Such measures are crucial at high field strengths. SS SE-EPI with SENSE offers further benefits in this regard and is more specific for oxygenation changes in the microvasculature bed. Functional brain activity can be investigated with the help of single-shot spin echo EPI using SENSE at high magnetic fields.

  12. Single-shot secure quantum network coding on butterfly network with free public communication

    Science.gov (United States)

    Owari, Masaki; Kato, Go; Hayashi, Masahito

    2018-01-01

    Quantum network coding on the butterfly network has been studied as a typical example of quantum multiple cast network. We propose a secure quantum network code for the butterfly network with free public classical communication in the multiple unicast setting under restricted eavesdropper’s power. This protocol certainly transmits quantum states when there is no attack. We also show the secrecy with shared randomness as additional resource when the eavesdropper wiretaps one of the channels in the butterfly network and also derives the information sending through public classical communication. Our protocol does not require verification process, which ensures single-shot security.

  13. Single-shot femtosecond-pulsed phase-shifting digital holography.

    Science.gov (United States)

    Kakue, Takashi; Itoh, Seiya; Xia, Peng; Tahara, Tatsuki; Awatsuji, Yasuhiro; Nishio, Kenzo; Ura, Shogo; Kubota, Toshihiro; Matoba, Osamu

    2012-08-27

    Parallel phase-shifting digital holography is capable of three-dimensional measurement of a dynamically moving object with a single-shot recording. In this letter, we demonstrated a parallel phase-shifting digital holography using a single femtosecond light pulse whose central wavelength and temporal duration were 800 nm and 96 fs, respectively. As an object, we set spark discharge in atmospheric pressure air induced by applying a high voltage to between two electrodes. The instantaneous change in phase caused by the spark discharge was clearly reconstructed. The reconstructed phase image shows the change of refractive index of air was -3.7 × 10(-4).

  14. Single-shot magnetic resonance spectroscopic imaging with partial parallel imaging.

    Science.gov (United States)

    Posse, Stefan; Otazo, Ricardo; Tsai, Shang-Yueh; Yoshimoto, Akio Ernesto; Lin, Fa-Hsuan

    2009-03-01

    A magnetic resonance spectroscopic imaging (MRSI) pulse sequence based on proton-echo-planar-spectroscopic-imaging (PEPSI) is introduced that measures two-dimensional metabolite maps in a single excitation. Echo-planar spatial-spectral encoding was combined with interleaved phase encoding and parallel imaging using SENSE to reconstruct absorption mode spectra. The symmetrical k-space trajectory compensates phase errors due to convolution of spatial and spectral encoding. Single-shot MRSI at short TE was evaluated in phantoms and in vivo on a 3-T whole-body scanner equipped with a 12-channel array coil. Four-step interleaved phase encoding and fourfold SENSE acceleration were used to encode a 16 x 16 spatial matrix with a 390-Hz spectral width. Comparison with conventional PEPSI and PEPSI with fourfold SENSE acceleration demonstrated comparable sensitivity per unit time when taking into account g-factor-related noise increases and differences in sampling efficiency. LCModel fitting enabled quantification of inositol, choline, creatine, and N-acetyl-aspartate (NAA) in vivo with concentration values in the ranges measured with conventional PEPSI and SENSE-accelerated PEPSI. Cramer-Rao lower bounds were comparable to those obtained with conventional SENSE-accelerated PEPSI at the same voxel size and measurement time. This single-shot MRSI method is therefore suitable for applications that require high temporal resolution to monitor temporal dynamics or to reduce sensitivity to tissue movement.

  15. Single shot trajectory design for region-specific imaging using linear and nonlinear magnetic encoding fields.

    Science.gov (United States)

    Layton, Kelvin J; Gallichan, Daniel; Testud, Frederik; Cocosco, Chris A; Welz, Anna M; Barmet, Christoph; Pruessmann, Klaas P; Hennig, Jürgen; Zaitsev, Maxim

    2013-09-01

    It has recently been demonstrated that nonlinear encoding fields result in a spatially varying resolution. This work develops an automated procedure to design single-shot trajectories that create a local resolution improvement in a region of interest. The technique is based on the design of optimized local k-space trajectories and can be applied to arbitrary hardware configurations that employ any number of linear and nonlinear encoding fields. The trajectories designed in this work are tested with the currently available hardware setup consisting of three standard linear gradients and two quadrupolar encoding fields generated from a custom-built gradient insert. A field camera is used to measure the actual encoding trajectories up to third-order terms, enabling accurate reconstructions of these demanding single-shot trajectories, although the eddy current and concomitant field terms of the gradient insert have not been completely characterized. The local resolution improvement is demonstrated in phantom and in vivo experiments. Copyright © 2012 Wiley Periodicals, Inc.

  16. Optimization And Single-Shot Characterization Of Ultrashort Thz Pulses From A Laser Wakefield Accelerator

    International Nuclear Information System (INIS)

    Plateau, G.R.; Matlis, N.H.; van Tilborg, J.; Geddes, C.G.R.; Toth, Cs.; Schroeder, C.B.; Leemans, W.P.

    2009-01-01

    We present spatiotemporal characterization of μJ-class ultrashort THz pulses generated from a laser wakefield accelerator (LWFA). Accelerated electrons, resulting from the interaction of a high-intensity laser pulse with a plasma, emit high-intensity THz pulses as coherent transition radiation. Such high peak-power THz pulses, suitable for high-field (MV/cm) pump-probe experiments, also provide a non-invasive bunch-length diagnostic and thus feedback for the accelerator. The characterization of the THz pulses includes energy measurement using a Golay cell, 2D sign-resolved electro-optic measurement and single-shot spatiotemporal electric-field distribution retrieval using a new technique, coined temporal electric-field cross-Correlation (TEX). All three techniques corroborate THz pulses of ∼ 5 μJ, with peak fields of 100's of kV/cm and ∼ 0.4 ps rms duration.

  17. Single-Shot Quantum Nondemolition Detection of Individual Itinerant Microwave Photons

    Science.gov (United States)

    Besse, Jean-Claude; Gasparinetti, Simone; Collodo, Michele C.; Walter, Theo; Kurpiers, Philipp; Pechal, Marek; Eichler, Christopher; Wallraff, Andreas

    2018-04-01

    Single-photon detection is an essential component in many experiments in quantum optics, but it remains challenging in the microwave domain. We realize a quantum nondemolition detector for propagating microwave photons and characterize its performance using a single-photon source. To this aim, we implement a cavity-assisted conditional phase gate between the incoming photon and a superconducting artificial atom. By reading out the state of this atom in a single shot, we reach an external (internal) photon-detection fidelity of 50% (71%), limited by transmission efficiency between the source and the detector (75%) and the coherence properties of the qubit. By characterizing the coherence and average number of photons in the field reflected off the detector, we demonstrate its quantum nondemolition nature. We envisage applications in generating heralded remote entanglement between qubits and for realizing logic gates between propagating microwave photons.

  18. Single-shot parallel full range complex Fourier-domain optical coherence tomography

    International Nuclear Information System (INIS)

    Huang Bingjie; Bu Peng; Nan Nan; Wang Xiangzhao

    2011-01-01

    We present a method of parallel full range complex Fourier-domain optical coherence tomography (FDOCT) that is capable of acquiring an artifacts-free two-dimensional (2-D) cross-sectional image, i.e. a full range B-scan tomogram, by a single shot of 2-D CCD camera. This method is based on a spatial carrier technique, in which the spatial carrier-frequency is instantaneously introduced into the 2-D spectral interferogram registered in parallel FDOCT by using a grating-generated reference beam. The spatial-carrier-contained 2-D spectral interferogram is processed through Fourier transformation to obtain a complex 2-D spectral interferogram. From the 2-D complex spectral interferomgram, a full range B-scan tomogram is reconstructed. The principle of our method is confirmed by imaging an onion sample.

  19. Single-shot and single-spot measurement of laser ablation threshold for carbon nanotubes

    International Nuclear Information System (INIS)

    Lednev, Vasily N; Pershin, Sergey M; Bunkin, Alexey F; Obraztsova, Elena D; Kudryashov, Sergey I

    2013-01-01

    A simple and convenient procedure for single-shot, single-spot ablation threshold measurement is developed. It is based on the employment of cylindrical lens to obtain an elliptical Gaussian laser spot. The ablated spot chords that are parallel to the minor axis are measured across the spot major axis, which is proportional to the fluence cross-section, thus providing wide range dependence of damaged spot size versus fluence in one spot measurement. For both conventional and newly developed procedures the ablation threshold for typical Nd:YAG laser parameters (1064 nm, 10 ns) is measured as 50 ± 5 mJ cm -2 , which is one order of magnitude lower than that for bulk graphite.

  20. Kinematic MRI using short TR single shot fast spin echo (SSFSE) in evaluating swallowing

    Energy Technology Data Exchange (ETDEWEB)

    Isogai, Satoshi; Takehara, Yasuo; Isoda, Haruo; Kodaira, Nami; Masunaga, Hatsuko; Ozawa, Fukujirou; Kaneko, Masao [Hamamatsu Univ. School of Medicine, Shizuoka (Japan); Nozaki, Atsushi; Kabasawa, Hiroyuki

    1999-03-01

    The utility of short TR single shot fast spin echo (SSFSE) MR imaging for evaluating swallowing was determined. Five healthy volunteers underwent kinematic MR imaging of swallowing with a 1.5 T MR scanner using the short TR (300 ms) SSFSE sequence. Twenty phases of sagittal sections were acquired within 6 sec, where the temporal resolution was 300 ms. For oral contrast medium, we used prune yogurt juice with Fe added. The image contrast of short TR SSFSE was found to be somewhere like that of T1-weighted images. In all cases, both the buccal and pharyngeal stages of swallowing were successfully depicted. The Fe-added prune yogurt juice performed as a positive contrast medium and helped determine anatomical structures in the buccal stage. Short TR (300 ms) SSFSE was useful in evaluating swallowing. The combined use of Fe-added prune yogurt juice was helpful in enhancing the surface of the oropharynx. (author)

  1. Kinematic MRI using short TR single shot fast spin echo (SSFSE) in evaluating swallowing

    International Nuclear Information System (INIS)

    Isogai, Satoshi; Takehara, Yasuo; Isoda, Haruo; Kodaira, Nami; Masunaga, Hatsuko; Ozawa, Fukujirou; Kaneko, Masao; Nozaki, Atsushi; Kabasawa, Hiroyuki

    1999-01-01

    The utility of short TR single shot fast spin echo (SSFSE) MR imaging for evaluating swallowing was determined. Five healthy volunteers underwent kinematic MR imaging of swallowing with a 1.5 T MR scanner using the short TR (300 ms) SSFSE sequence. Twenty phases of sagittal sections were acquired within 6 sec, where the temporal resolution was 300 ms. For oral contrast medium, we used prune yogurt juice with Fe added. The image contrast of short TR SSFSE was found to be somewhere like that of T1-weighted images. In all cases, both the buccal and pharyngeal stages of swallowing were successfully depicted. The Fe-added prune yogurt juice performed as a positive contrast medium and helped determine anatomical structures in the buccal stage. Short TR (300 ms) SSFSE was useful in evaluating swallowing. The combined use of Fe-added prune yogurt juice was helpful in enhancing the surface of the oropharynx. (author)

  2. Fast Detection of Airports on Remote Sensing Images with Single Shot MultiBox Detector

    Science.gov (United States)

    Xia, Fei; Li, HuiZhou

    2018-01-01

    This paper introduces a method for fast airport detection on remote sensing images (RSIs) using Single Shot MultiBox Detector (SSD). To our knowledge, this could be the first study which introduces an end-to-end detection model into airport detection on RSIs. Based on the common low-level features between natural images and RSIs, a convolution neural network trained on large amounts of natural images was transferred to tackle the airport detection problem with limited annotated data. To deal with the specific characteristics of RSIs, some related parameters in the SSD, such as the scales and layers, were modified for more accurate and rapider detection. The experiments show that the proposed method could achieve 83.5% Average Recall at 8 FPS on RSIs with the size of 1024*1024. In contrast to Faster R-CNN, an improvement on AP and speed could be obtained.

  3. Compressive sensing sectional imaging for single-shot in-line self-interference incoherent holography

    Science.gov (United States)

    Weng, Jiawen; Clark, David C.; Kim, Myung K.

    2016-05-01

    A numerical reconstruction method based on compressive sensing (CS) for self-interference incoherent digital holography (SIDH) is proposed to achieve sectional imaging by single-shot in-line self-interference incoherent hologram. The sensing operator is built up based on the physical mechanism of SIDH according to CS theory, and a recovery algorithm is employed for image restoration. Numerical simulation and experimental studies employing LEDs as discrete point-sources and resolution targets as extended sources are performed to demonstrate the feasibility and validity of the method. The intensity distribution and the axial resolution along the propagation direction of SIDH by angular spectrum method (ASM) and by CS are discussed. The analysis result shows that compared to ASM the reconstruction by CS can improve the axial resolution of SIDH, and achieve sectional imaging. The proposed method may be useful to 3D analysis of dynamic systems.

  4. Method for single-shot measurement of picosecond laser pulse-lengths without electronic time dispersion

    International Nuclear Information System (INIS)

    Kyrala, G.A.

    1987-01-01

    A two-source shear pattern recording is proposed as a method for single-shot measurement of the pulse shape from nearly monochromatic sources whose pulse lengths are shorter than their coherence times. The basis of this method relies on the assertion that if two identical electromagnetic pulses are recombined with a time delay greater than the sum of their pulse widths, the recordable spatial pattern has no fringes in it. At an arbitrary delay, translated into an actual spatial recording position, the recorded modulated intensity will sample the corresponding laser intensity at that delay time, but with a modulation due to the coherence function of the electromagnetic pulse. Two arrangements are proposed for recording the pattern. The principles, the design parameters, and the methodologies of these arrangements are presented. Resolutions of the configurations and their limitations are given as well

  5. Development of a single-shot-imaging thin film for an online Thomson parabola spectrometer

    International Nuclear Information System (INIS)

    Sakaki, H.; Fukuda, Y.; Nishiuchi, M.; Hori, T.; Yogo, A.; Jinno, S.; Kanasaki, M.; Niita, K.

    2013-01-01

    A single-shot-imaging thin scintillator film was developed for an online Thomson parabola (TP) spectrometer and the first analysis of laser accelerated ions, using the online TP spectrometer, was demonstrated at the JAEA-Kansai Advanced Relativistic Engineering Laser System (J-KAREN). An energy spectrum of ∼4.0 MeV protons is obtained using only this imaging film without the need of a microchannel plate that is typically utilized in online ion analyses. A general-purpose Monte Carlo particle and heavy ion-transport code system, which consists of various quantum dynamics models, was used for the prediction of the luminescent properties of the scintillator. The simulation can reasonably predict not only the ion trajectories detected by the spectrometer, but also luminescence properties.

  6. Single-shot electro-optic experiments for electron bunch diagnostics at Tsinghua Accelerator Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Wei; Du, Yingchao; Yan, Lixin; Hua, Jianfei; Zhang, Zhen; Zhou, Zheng [Accelerator Laboratory, Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education, Beijing 100084 (China); Huang, Wenhui, E-mail: huangwh@mail.tsinghua.edu.cn [Accelerator Laboratory, Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education, Beijing 100084 (China); Tang, Chuanxiang [Accelerator Laboratory, Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle and Radiation Imaging, Tsinghua University, Ministry of Education, Beijing 100084 (China); Li, Ming [Institute of Applied Electronics, China Academy of Engineering Physics, Mianyang 621900 (China)

    2016-10-21

    The electro-optic (EO) technique detects the Coulomb electric field distribution of relativistic electron bunches to obtain the associated longitudinal profile. This diagnostic method allows the direct time-resolved single-shot measurement and thus the real-time monitoring of the bunch profile and beam arrival time in a non-destructive way with sub-picosecond temporal resolution. In this paper, we report the measurement of the longitudinal profile of an electron bunch through electro-optic spectral decoding detection, in which the bunch profile is encoded into the spectra of the linearly chirped laser pulse. The experimental setup and measurement results of a 40 MeV electron bunch are presented, with a temporal profile length of 527 fs rms (~1.24 ps FWHM) and a beam arrival time jitter of 471 fs rms. Temporal resolution and future experimental improvement are also discussed.

  7. Radiography simulation on single-shot dual-spectrum X-ray for cargo inspection system

    International Nuclear Information System (INIS)

    Gil, Youngmi; Oh, Youngdo; Cho, Moohyun; Namkung, Won

    2011-01-01

    We propose a method to identify materials in the dual energy X-ray (DeX) inspection system. This method identifies materials by combining information on the relative proportions T of high-energy and low-energy X-rays transmitted through the material, and the ratio R of the attenuation coefficient of the material when high-energy are used to that when low energy X-rays are used. In Monte Carlo N-Particle Transport Code (MCNPX) simulations using the same geometry as that of the real container inspection system, this T vs. R method successfully identified tissue-equivalent plastic and several metals. In further simulations, the single-shot mode of operating the accelerator led to better distinguishing of materials than the dual-shot system.

  8. 3 ns single-shot read-out in a quantum dot-based memory structure

    International Nuclear Information System (INIS)

    Nowozin, T.; Bimberg, D.; Beckel, A.; Lorke, A.; Geller, M.

    2014-01-01

    Fast read-out of two to six charges per dot from the ground and first excited state in a quantum dot (QD)-based memory is demonstrated using a two-dimensional electron gas. Single-shot measurements on modulation-doped field-effect transistor structures with embedded InAs/GaAs QDs show read-out times as short as 3 ns. At low temperature (T = 4.2 K) this read-out time is still limited by the parasitics of the setup and the device structure. Faster read-out times and a larger read-out signal are expected for an improved setup and device structure

  9. Hyperspectral interferometry for single-shot absolute measurement of 3-D shape and displacement fields

    Directory of Open Access Journals (Sweden)

    Ruiz P. D.

    2010-06-01

    Full Text Available We propose a method that we call Hyperspectral Interferometry (HSI to resolve the 2π phase unwrapping problem in the analysis of interferograms recorded with a narrow-band light source. By using a broad-band light source and hyperspectral imaging system, a set of interferograms at different wavenumbers are recorded simultaneously on a high resolution image sensor. These are then assembled to form a three-dimensional intensity distribution. By Fourier transformation along the wavenumber axis, an absolute optical path difference is obtained for each pixel independently of the other pixels in the field of view. As a result, interferograms with spatially distinct regions are analysed as easily as continuous ones. The approach is illustrated with a HSI system to measure 3-D profiles of optically smooth or rough surfaces. Compared to existing profilometers able to measure absolute path differences, the single shot nature of the approach provides greater immunity from environmental disturbance.

  10. Single-shot quantitative phase microscopy with color-multiplexed differential phase contrast (cDPC.

    Directory of Open Access Journals (Sweden)

    Zachary F Phillips

    Full Text Available We present a new technique for quantitative phase and amplitude microscopy from a single color image with coded illumination. Our system consists of a commercial brightfield microscope with one hardware modification-an inexpensive 3D printed condenser insert. The method, color-multiplexed Differential Phase Contrast (cDPC, is a single-shot variant of Differential Phase Contrast (DPC, which recovers the phase of a sample from images with asymmetric illumination. We employ partially coherent illumination to achieve resolution corresponding to 2× the objective NA. Quantitative phase can then be used to synthesize DIC and phase contrast images or extract shape and density. We demonstrate amplitude and phase recovery at camera-limited frame rates (50 fps for various in vitro cell samples and c. elegans in a micro-fluidic channel.

  11. Single-shot dual-wavelength in-line and off-axis hybrid digital holography

    Science.gov (United States)

    Wang, Fengpeng; Wang, Dayong; Rong, Lu; Wang, Yunxin; Zhao, Jie

    2018-02-01

    We propose an in-line and off-axis hybrid holographic real-time imaging technique. The in-line and off-axis digital holograms are generated simultaneously by two lasers with different wavelengths, and they are recorded using a color camera with a single shot. The reconstruction is carried using an iterative algorithm in which the initial input is designed to include the intensity of the in-line hologram and the approximate phase distributions obtained from the off-axis hologram. In this way, the complex field in the object plane and the output by the iterative procedure can produce higher quality amplitude and phase images compared to traditional iterative phase retrieval. The performance of the technique has been demonstrated by acquiring the amplitude and phase images of a green lacewing's wing and a living moon jellyfish.

  12. A versatile diffractive maskless lithography for single-shot and serial microfabrication.

    Science.gov (United States)

    Jenness, Nathan J; Hill, Ryan T; Hucknall, Angus; Chilkoti, Ashutosh; Clark, Robert L

    2010-05-24

    We demonstrate a diffractive maskless lithographic system that is capable of rapidly performing both serial and single-shot micropatterning. Utilizing the diffractive properties of phase holograms displayed on a spatial light modulator, arbitrary intensity distributions were produced to form two and three dimensional micropatterns/structures in a variety of substrates. A straightforward graphical user interface was implemented to allow users to load templates and change patterning modes within the span of a few minutes. A minimum resolution of approximately 700 nm is demonstrated for both patterning modes, which compares favorably to the 232 nm resolution limit predicted by the Rayleigh criterion. The presented method is rapid and adaptable, allowing for the parallel fabrication of microstructures in photoresist as well as the fabrication of protein microstructures that retain functional activity.

  13. Ultrafast T2-weighted single shot spin-echo sequences: applications on abdominal and pelvic pathologies

    International Nuclear Information System (INIS)

    Martin, J.; Martin, C.; Falco, J.; Esteban, L.

    1999-01-01

    The magnetic resonance imaging (MRI) sequences that obtain all the data using a sole excitation pulse of 90 degree centigrade, filling the K space in a single repetition time (TR) is known as snap shot or single shot (SS). The SS sequence based on the rapid acquisition with relaxation enhancement (SS-RARE) method, designed by Hening (1) and a variation of it with a half-Fourier reconstruction (SS-HF-RARE (HASTEL)) (2, 3) are capable of obtaining high contrast images in T2, in very short times, that oscillate between one to several seconds. The clinical application of these sequences to abdominal and pelvic pathologies is increasing, providing and improvement in the contrast resolution, but also in the spatial resolution, with a high relation signal/noise ratio, high contrast and absence of movement artifacts. (Author)

  14. Single-shot beam size measurements using visible-light interferometry at CESR

    Energy Technology Data Exchange (ETDEWEB)

    Wang, S.T., E-mail: sw565@cornell.edu [Cornell Laboratory for Accelerator-based Science and Education, Cornell University, Ithaca, NY 14853 (United States); Holtzapple, R. [Physics Department, California Polytechnic State University, San Luis Obispo, CA 93407 (United States); Rubin, D.L. [Cornell Laboratory for Accelerator-based Science and Education, Cornell University, Ithaca, NY 14853 (United States)

    2017-03-01

    A new primary mirror for a visible-light beam size monitor (vBSM) was designed and installed in the Cornell Electron-Positron Storage Ring (CESR). The vertical angular acceptance of the mirror was doubled to allow double-slit interferometry with large slit separation (>12 mm). In addition, the diffraction associated with the first generation mirror has been eliminated. The resolution of the vertical beam size measurements has been dramatically improved but is ultimately limited by the beam motion. Two fast-response detectors, a Photomultiplier Tube (PMT) array and a gated camera, were employed to study the beam motion. The advantages and limitations of both devices are discussed in this paper. The gated camera was also used to measure single-shot beam width and motion of each bunch in a multi-bunch train. We measured significantly more horizontal motion of electron as compared to positron bunch trains in otherwise identical machine condition. This difference may be a signature for the difference between electron cloud build-up for positron bunch trains versus ions effects characteristic of electron bunch trains. - Highlights: • A new extraction mirror for synchrotron radiation was designed and installed in CESR. • The sensitivity of interferometer was increased and the diffraction effect was eliminated. • Two fast-response detectors were employed to study the effect of beam motion. • First time single-shot bunch-by-bunch horizontal beam size measurements using interferometry was observed from gated camera. • The difference in single bunch horizontal dynamics was observed between a positron and an electron train.

  15. Comparison of ropivacaine and bupivacaine as single-shot epidural anaesthesia for orthopaedic surgery

    International Nuclear Information System (INIS)

    Riaz, A.; Khan, A.S.

    2015-01-01

    To compare the efficacy and side-effects of 0.5% ropivacaine with that of 0.5% bupivacaine when used for single-shot epidural anaesthesia for orthopaedic surgery. Design: Randomized controlled trial. Place and Duration of Study: Department of Anesthesiology, Combined Military Hospital Rawalpindi, over a period of eight months from June 2013 to January 2014. Patients and Methods: The study was carried out in 60 ASA physical status I, II or III patients undergoing elective lower extremity orthopedic surgery. Two groups of 30 patients each received single-shot epidural anaesthesia either with ropivacaine 0.5% (ropivacaine group) or bupivacaine 0.5% (bupivacaine group). Onset, time for maximum height and median height of sensory block was assessed as well as time to two segment recession. Modified Bromage scale was used for motor blockade. Total duration of motor block and common side effects were also recorded. Results: The patients in both groups were similar in age, height, weight, gender and ASA status. There was no significant difference in onset of sensory block and time for maximum height of sensory block. The median heighest level of sensory block was T6 (T5-T8) for ropivacaine group and T5 (T4-T7) for bupivacaine group. Time for two segment regression and duration of sensory block were also comparable for both groups. The total duration of motor block was significantly more in bupivacaine group (159 min vs 134.2 min, p< 0.001). Modified Bromage scale was also significantly higher in bupivacaine group (2.86 vs 1.96 min, p<0.001). Side effects like hypotension, bradycardia, nausea, vomiting and shivering were similar in both groups. Conclusion: Epidural administration of 0.5% ropivacaine provided effective and good quality anaesthesia. Motor blockade was of less duration as compared to equivalent dose of 0.5% bupivacaine, which may offer potential benefit of early patient mobilization after orthopaedic surgery. (author)

  16. Fourier Analysis of Single-Shot Dual-Energy X-ray Imaging Characteristics

    International Nuclear Information System (INIS)

    Kim, Jun Woo; Kim, Dong Woon; Kim, Ho Kyung

    2016-01-01

    The sandwich detector was realized by stacking two scintillator-based flat-panel detectors (FPDs) between which an intermediate copper (Cu) filter layer was placed to further enhance spectral energy separation. As a result, the proper selection of filter material and its thickness could be a trade-off between the extent of energy separation (hence, DE image quality) and image noise due to reduction in the number of x-ray quanta reaching the rear FPD. Although the conventional kVp-switching dual-shot method showed better image qualities than the single-shot method because of larger spectral energy separation, the motion-artifact-free DE image with reasonably good image quality was a potential prospect of the single-shot method. For the reliable and better use of the sandwich detector for specific imaging applications, the sandwich detector should be optimally designed with a proper selection of scintillator material and thickness in each detector layer (i.e. the front and rear detectors), and aforementioned intermediate filter material and thickness. It is noted that glue is used to adhere the fragile photodiode array onto the ceramic substrate and these glue patterns are apparent in the rear and DE images. The glue pattern in the rear image comes from the front FPD. Unlike the conventional ESF as shown in Fig. 3(a), the ESF obtained from the subtracted image showed an enhancement as shown in Fig. 3(b). Consequently, the MTF obtained from the subtraction ESF showed a bandpass filter characteristic, as shown in Fig. 3(c), unlike the conventional low-pass filter characteristic (i.e., monotonic decrease of MTF value with increasing the spatial frequency). This MTF characteristic is due to the subtraction of two images with different spatial resolving powers (i.e., different thicknesses of phosphors between the front and rear detectors) as can be seen in unsharp masking digital image processing, which subtracts Gaussian-blurred image from the original image

  17. Fourier Analysis of Single-Shot Dual-Energy X-ray Imaging Characteristics

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jun Woo; Kim, Dong Woon; Kim, Ho Kyung [Pusan National University, Busan (Korea, Republic of)

    2016-05-15

    The sandwich detector was realized by stacking two scintillator-based flat-panel detectors (FPDs) between which an intermediate copper (Cu) filter layer was placed to further enhance spectral energy separation. As a result, the proper selection of filter material and its thickness could be a trade-off between the extent of energy separation (hence, DE image quality) and image noise due to reduction in the number of x-ray quanta reaching the rear FPD. Although the conventional kVp-switching dual-shot method showed better image qualities than the single-shot method because of larger spectral energy separation, the motion-artifact-free DE image with reasonably good image quality was a potential prospect of the single-shot method. For the reliable and better use of the sandwich detector for specific imaging applications, the sandwich detector should be optimally designed with a proper selection of scintillator material and thickness in each detector layer (i.e. the front and rear detectors), and aforementioned intermediate filter material and thickness. It is noted that glue is used to adhere the fragile photodiode array onto the ceramic substrate and these glue patterns are apparent in the rear and DE images. The glue pattern in the rear image comes from the front FPD. Unlike the conventional ESF as shown in Fig. 3(a), the ESF obtained from the subtracted image showed an enhancement as shown in Fig. 3(b). Consequently, the MTF obtained from the subtraction ESF showed a bandpass filter characteristic, as shown in Fig. 3(c), unlike the conventional low-pass filter characteristic (i.e., monotonic decrease of MTF value with increasing the spatial frequency). This MTF characteristic is due to the subtraction of two images with different spatial resolving powers (i.e., different thicknesses of phosphors between the front and rear detectors) as can be seen in unsharp masking digital image processing, which subtracts Gaussian-blurred image from the original image.

  18. Modelling single shot damage thresholds of multilayer optics for high-intensity short-wavelength radiation sources

    NARCIS (Netherlands)

    Loch, R.A.; Sobierajski, R.; Louis, Eric; Bosgra, J.; Bosgra, J.; Bijkerk, Frederik

    2012-01-01

    The single shot damage thresholds of multilayer optics for highintensity short-wavelength radiation sources are theoretically investigated, using a model developed on the basis of experimental data obtained at the FLASH and LCLS free electron lasers. We compare the radiation hardness of commonly

  19. Single-shot Thomson scattering on argon plasmas created by the Microwave Plasma Torch; evidence for a new plasma class

    NARCIS (Netherlands)

    Mullen, van der J.J.A.M.; Sande, van de M.J.; Vries, de N.; Broks, B.H.P.; Iordanova, E.I.; Gamero, A.; Torres, J.; Sola, A.

    2007-01-01

    To determine the fine-structure size of plasmas created by a Microwave Plasma Torch (MPT), single-shot Thomson scattering (TS) measurements were performed. The aim was to find a solution for the long-standing discrepancy between experiments and Global Plasma Models (GPMs). Since these GPMs are based

  20. A TV camera system for digitizing single shot oscillograms at sweep rate of 0.1 ns/cm

    International Nuclear Information System (INIS)

    Kienlen, M.; Knispel, G.; Miehe, J.A.; Sipp, B.

    1976-01-01

    A TV camera digitizing system associated with a 5 GHz photocell-oscilloscope apparatus allows the digitizing of single shot oscillograms; with an oscilloscope sweep rate of 0.1 ns/cm an accuracy on time measurements of 4 ps is obtained [fr

  1. Frequency-Domain Tomography for Single-shot, Ultrafast Imaging of Evolving Laser-Plasma Accelerators

    Science.gov (United States)

    Li, Zhengyan; Zgadzaj, Rafal; Wang, Xiaoming; Downer, Michael

    2011-10-01

    Intense laser pulses propagating through plasma create plasma wakefields that often evolve significantly, e.g. by expanding and contracting. However, such dynamics are known in detail only through intensive simulations. Laboratory visualization of evolving plasma wakes in the ``bubble'' regime is important for optimizing and scaling laser-plasma accelerators. Recently snap-shots of quasi-static wakes were recorded using frequency-domain holography (FDH). To visualize the wake's evolution, we have generalized FDH to frequency-domain tomography (FDT), which uses multiple probes propagating at different angles with respect to the pump pulse. Each probe records a phase streak, imprinting a partial record of the evolution of pump-created structures. We then topographically reconstruct the full evolution from all phase streaks. To prove the concept, a prototype experiment visualizing nonlinear index evolution in glass is demonstrated. Four probes propagating at 0, 0.6, 2, 14 degrees to the index ``bubble'' are angularly and temporally multiplexed to a single spectrometer to achieve cost-effective FDT. From these four phase streaks, an FDT algorithm analogous to conventional CT yields a single-shot movie of the pump's self-focusing dynamics.

  2. Single shot imaging through turbid medium and around corner using coherent light

    Science.gov (United States)

    Li, Guowei; Li, Dayan; Situ, Guohai

    2018-01-01

    Optical imaging through turbid media and around corner is a difficult challenge. Even a very thin layer of a turbid media, which randomly scatters the probe light, can appear opaque and hide any objects behind it. Despite many recent advances, no current method can image the object behind turbid media with single record using coherent laser illumination. Here we report a method that allows non-invasive single-shot optical imaging through turbid media and around corner via speckle correlation. Instead of being as an obstacle in forming diffractionlimited images, speckle actually can be a carrier that encodes sufficient information to imaging through visually opaque layers. Optical imaging through turbid media and around corner is experimentally demonstrated using traditional imaging system with the aid of iterative phase retrieval algorithm. Our method require neither scan of illumination nor two-arm interferometry or long-time exposure in acquisition, which has new implications in optical sensing through common obscurants such as fog, smoke and haze.

  3. Single-shot femtosecond laser ablation of gold surface in air and isopropyl alcohol

    Science.gov (United States)

    Kudryashov, S. I.; Saraeva, I. N.; Lednev, V. N.; Pershin, S. M.; Rudenko, A. A.; Ionin, A. A.

    2018-05-01

    Single-shot IR femtosecond-laser ablation of gold surfaces in ambient air and liquid isopropyl alcohol was studied by scanning electron microscopy characterization of crater topographies and time-resolved optical emission spectroscopy of ablative plumes in regimes, typical for non-filamentary and non-fragmentation laser production of nanoparticle sols. Despite one order of magnitude shorter (few nanoseconds) lifetimes and almost two orders of magnitude lower intensities of the quenched ablative plume emission in the alcohol ambient at the same peak laser fluence, craters for the dry and wet conditions appeared with rather similar nanofoam-like spallative topographies and the same thresholds. These facts envision the underlying surface spallation as one of the basic ablation mechanisms relevant for both dry and wet advanced femtosecond laser surface nano/micro-machining and texturing, as well as for high-throughput femtosecond laser ablative production of colloidal nanoparticles by MHz laser-pulse trains via their direct nanoscale jetting from the nanofoam in air and fluid environments.

  4. The single-shot opto-digitizer; L'optoechantillonneur monocoup

    Energy Technology Data Exchange (ETDEWEB)

    Nail, M.; Gibert, Ph. [CEA/DAM-Ile de France, Dept. de Conception et Realisation des Experimentations (DCRE), 91 - Bruyeres-le-Chatel (France); CEA/DAM-Ile de France, Dept. Laser Puissance, DLP, 91 - Bruyeres-Le-Chatel (France)

    2000-07-01

    Laser-plasma experiments need to measure signals provided either by X-ray, photonic or neutronic detector. The measurement should have 50 GHz bandwidth and up to several hundred of Giga-Hertz for sub picosecond plasmas. For this purpose, a 35 GHz single shot opto-digitizer (10 ps risetime) has been studied and built. The device is made up of a 50 ohms microstrip propagation line, periodically lined by 100 sampled gates. The propagation line is long enough to measure a 400 ps duration. The sampling rate is 250 Gsa/s (every 4 ps). The sampled gates are made with fast recombining photo-material and turn on by a subpicosecond laser pulse which is synchronized exactly with the analysed phenomena. Every gate is recording to a storing capacitor. After the recording, every capacitor charge is needed to built the signal that was displayed on the propagation line. The dynamic range of measurement is 47 for the entire device. The device can measure positive or negative signals from 1.5 to 70 Volts. To increase the bandwidth, two another kinds of opto-digitizer were studied: one is a buried stripline with 56 GHz band width, the other a 70 GHz coplanar transmission line. For the purpose of subpicosecond plasmas, a 30 coplanar waveguide opto-digitizer was studied. Characteristics are as followed: window of measurement 40 ps, sampling rate 1 ps, bandwidth 230 GHz. Finally, a bundle of optical fibers was used to propagate the laser beam on semiconductor gates. If the gates are lighted at the same time, i.e. if the optical fibers have the same length, we get a simultaneous addressing. By using different lengths of optical fibers, we can do a sequential addressing. So, the sampling rate becomes a combination of the distance between two adjacent sampled channels, and the difference in length of optical fibers. (author)

  5. Self-Calibrating Wave-Encoded Variable-Density Single-Shot Fast Spin Echo Imaging.

    Science.gov (United States)

    Chen, Feiyu; Taviani, Valentina; Tamir, Jonathan I; Cheng, Joseph Y; Zhang, Tao; Song, Qiong; Hargreaves, Brian A; Pauly, John M; Vasanawala, Shreyas S

    2018-04-01

    It is highly desirable in clinical abdominal MR scans to accelerate single-shot fast spin echo (SSFSE) imaging and reduce blurring due to T 2 decay and partial-Fourier acquisition. To develop and investigate the clinical feasibility of wave-encoded variable-density SSFSE imaging for improved image quality and scan time reduction. Prospective controlled clinical trial. With Institutional Review Board approval and informed consent, the proposed method was assessed on 20 consecutive adult patients (10 male, 10 female, range, 24-84 years). A wave-encoded variable-density SSFSE sequence was developed for clinical 3.0T abdominal scans to enable high acceleration (3.5×) with full-Fourier acquisitions by: 1) introducing wave encoding with self-refocusing gradient waveforms to improve acquisition efficiency; 2) developing self-calibrated estimation of wave-encoding point-spread function and coil sensitivity to improve motion robustness; and 3) incorporating a parallel imaging and compressed sensing reconstruction to reconstruct highly accelerated datasets. Image quality was compared pairwise with standard Cartesian acquisition independently and blindly by two radiologists on a scale from -2 to 2 for noise, contrast, confidence, sharpness, and artifacts. The average ratio of scan time between these two approaches was also compared. A Wilcoxon signed-rank tests with a P value under 0.05 considered statistically significant. Wave-encoded variable-density SSFSE significantly reduced the perceived noise level and improved the sharpness of the abdominal wall and the kidneys compared with standard acquisition (mean scores 0.8, 1.2, and 0.8, respectively, P variable-density sampling SSFSE achieves improved image quality with clinically relevant echo time and reduced scan time, thus providing a fast and robust approach for clinical SSFSE imaging. 1 Technical Efficacy: Stage 6 J. Magn. Reson. Imaging 2018;47:954-966. © 2017 International Society for Magnetic Resonance in Medicine.

  6. Hardware for quasi-single-shot multifrequency magnetic induction tomography (MIT): the Graz Mk2 system

    International Nuclear Information System (INIS)

    Scharfetter, H; Köstinger, A; Issa, S

    2008-01-01

    Magnetic induction tomography (MIT) has been suggested by several groups for the contact-less mapping of the passive electrical properties of tissues via AC magnetic fields in the frequency range between several tens of kHz and several tens of MHz. Multifrequency MIT as an analog to multifrequency EIT has been tried and first image reconstructions have been demonstrated with phantoms. MIT appears to yield comparable images to EIT but offers the advantage of being non-contacting. In the beta-dispersion range of most tissues the method is challenging because the signals are very small and buried in noise. In order to minimize drifts and systematic errors fast data acquisition is therefore pivotal. This paper presents a method for single-shot MIT which allows us to acquire the data for a multifrequency image with an analog bandwidth of 50 kHz–1.5 MHz which covers a good part of the β-dispersion of many tissues. The transmit (TX) coils are simultaneously driven by individual power amplifiers with a multisinus pattern with up to 3 A pp . The amplifiers are configured as current sources so as not to perturb the excitation fields by inappropriately terminated coils. The separation of the different TX channels after reception is achieved by splitting up the carrier frequencies into individual subcarriers with a narrow spacing of at most 300 Hz. In this way every TX coil is identifiable by its own subcarrier but the whole excitation band is contained within a few kHz. The real and imaginary parts of the received signals are extracted efficiently with FFT. The system noise and the sources for low-frequency perturbations are analyzed and characterized

  7. Magnetic resonance urography in pediatrics: utilization of ultrafast single-shot spin echo sequences

    International Nuclear Information System (INIS)

    Martin, C.; Martin, J.; Duran, C.; Rigol, S.; Rojo, J. C.

    1999-01-01

    To determine the value of magnetic resonance urography (MRU) using ultrafast single-shot (SS) rapid acquisition with relaxation enhancement (RARE) and half-Fourier (HF) SS-RARE (SS-HF-RARE or HASTE) in the evaluation of congenital urinary tract anomalies in pediatric patients, and their possible application as alternatives to intravenous urography (IVU). Eighteen children (11 boys and 7 girls) aged 2 months to 15 years (mean: 5 years) with a total of 19 congenital urinary tract anomalies were studies by MU using SS-RARE and HASTE sequences in a 1 Tesla scanner. All the patients had previously been studies by ultrasound (US) and IVU. Twelve patients required anesthesia. The images were acquired by means of a HASTE sequence with multisection technique (TR, infinite; TE e f, 87 msec; echo train, 128; interval between echoes, 10.9 msec; total acquisition time, 13 sections/12 seconds), and SS-RARE (TR, infinite; TE e f, 1.100 msec; echo train, 240, and acquisition time, 7 seconds). Four radiologists evaluated the images independently; two who reviewed the IV images in consensus and two who reviewed the MRU images in consensus. The images were evaluated to assess the dilatation of the urinary tract and their utility in detecting the level and cause of the obstruction. MRU images revealed the urinary tract dilation, the level of the obstruction and the type of anomaly in 18 patients (100%), while IVU provided this information in only 10 [ sensitivity, 53%, 95% confidence interval (29%, 76%)]. The mean time required for MRU was 20 minutes (range: 7 to 30 minutes), while that of IVU was 1,242 minutes (range: 45 to 1,440 minutes). MRU using ultrafast single-short spin echo sequences is a rapid and effective technique that permits and excellent evaluation of congenital urinary tract anomalies in pediatric patients and does not require the administration of contrast media or ionizing radiation. (Author) 10 refs

  8. Reference-free unwarping of single-shot spatiotemporally encoded MRI using asymmetric self-refocused echoes acquisition

    Science.gov (United States)

    Chen, Ying; Chen, Song; Zhong, Jianhui; Chen, Zhong

    2015-05-01

    This paper presents a phase evolution rewinding algorithm for correcting the geometric and intensity distortions in single-shot spatiotemporally encoded (SPEN) MRI with acquisition of asymmetric self-refocused echo trains. Using the field map calculated from the phase distribution of the source image, the off-resonance induced phase errors are successfully rewound through deconvolution. The alias-free partial Fourier transform reconstruction helps improve the signal-to-noise ratio of the field maps and the output images. The effectiveness of the proposed algorithm was validated through 7 T MRI experiments on a lemon, a water phantom, and in vivo rat head. SPEN imaging was evaluated using rapid acquisition by sequential excitation and refocusing (RASER) which produces uniform T2 weighting. The results indicate that the new technique can more robustly deal with the cases in which the images obtained with conventional single-shot spin-echo EPI are difficult to be restored due to serious field variations.

  9. High quality single shot diffraction patterns using ultrashort megaelectron volt electron beams from a radio frequency photoinjector

    Energy Technology Data Exchange (ETDEWEB)

    Musumeci, P.; Moody, J. T.; Scoby, C. M.; Gutierrez, M. S. [Department of Physics and Astronomy, UCLA, Los Angeles, California 90095 (United States); Bender, H. A.; Wilcox, N. S. [National Security Technologies, LLC, Los Alamos Operations, Los Alamos, New Mexico 87544 (United States)

    2010-01-15

    Single shot diffraction patterns using a 250-fs-long electron beam have been obtained at the UCLA Pegasus laboratory. High quality images with spatial resolution sufficient to distinguish closely spaced peaks in the Debye-Scherrer ring pattern have been recorded by scattering the 1.6 pC 3.5 MeV electron beam generated in the rf photoinjector off a 100-nm-thick Au foil. Dark current and high emittance particles are removed from the beam before sending it onto the diffraction target using a 1 mm diameter collimating hole. These results open the door to the study of irreversible phase transformations by single shot MeV electron diffraction.

  10. High quality single shot diffraction patterns using ultrashort megaelectron volt electron beams from a radio frequency photoinjector.

    Science.gov (United States)

    Musumeci, P; Moody, J T; Scoby, C M; Gutierrez, M S; Bender, H A; Wilcox, N S

    2010-01-01

    Single shot diffraction patterns using a 250-fs-long electron beam have been obtained at the UCLA Pegasus laboratory. High quality images with spatial resolution sufficient to distinguish closely spaced peaks in the Debye-Scherrer ring pattern have been recorded by scattering the 1.6 pC 3.5 MeV electron beam generated in the rf photoinjector off a 100-nm-thick Au foil. Dark current and high emittance particles are removed from the beam before sending it onto the diffraction target using a 1 mm diameter collimating hole. These results open the door to the study of irreversible phase transformations by single shot MeV electron diffraction.

  11. High quality single shot diffraction patterns using ultrashort megaelectron volt electron beams from a radio frequency photoinjector

    International Nuclear Information System (INIS)

    Musumeci, P.; Moody, J. T.; Scoby, C. M.; Gutierrez, M. S.; Bender, H. A.; Wilcox, N. S.

    2010-01-01

    Single shot diffraction patterns using a 250-fs-long electron beam have been obtained at the UCLA Pegasus laboratory. High quality images with spatial resolution sufficient to distinguish closely spaced peaks in the Debye-Scherrer ring pattern have been recorded by scattering the 1.6 pC 3.5 MeV electron beam generated in the rf photoinjector off a 100-nm-thick Au foil. Dark current and high emittance particles are removed from the beam before sending it onto the diffraction target using a 1 mm diameter collimating hole. These results open the door to the study of irreversible phase transformations by single shot MeV electron diffraction.

  12. Clinical evaluation of single-shot and readout-segmented diffusion-weighted imaging in stroke patients at 3 T

    International Nuclear Information System (INIS)

    Morelli, John; Porter, David; Ai, Fei

    2013-01-01

    Background: Diffusion-weighted imaging (DWI) magnetic resonance imaging (MRI) is most commonly performed utilizing a single-shot echo-planar imaging technique (ss-EPI). Susceptibility artifact and image blur are severe when this sequence is utilized at 3 T. Purpose: To evaluate a readout-segmented approach to DWI MR in comparison with single-shot echo planar imaging for brain MRI. Material and Methods: Eleven healthy volunteers and 14 patients with acute and early subacute infarctions underwent DWI MR examinations at 1.5 and 3T with ss-EPI and readout-segmented echo-planar (rs-EPI) DWI at equal nominal spatial resolutions. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) calculations were made, and two blinded readers ranked the scans in terms of high signal intensity bulk susceptibility artifact, spatial distortions, image blur, overall preference, and motion artifact. Results: SNR and CNR were greatest with rs-EPI (8.1 ± 0.2 SNR vs. 6.0 ± 0.2; P -4 at 3T). Spatial distortions were greater with single-shot (0.23 ± 0.03 at 3T; P <0.001) than with rs-EPI (0.12 ± 0.02 at 3T). Combined with blur and artifact reduction, this resulted in a qualitative preference for the readout-segmented scans overall. Conclusion: Substantial image quality improvements are possible with readout-segmented vs. single-shot EPI - the current clinical standard for DWI - regardless of field strength (1.5 or 3 T). This results in improved image quality secondary to greater real spatial resolution and reduced artifacts from susceptibility in MR imaging of the brain

  13. Accelerator-based Single-shot Ultrafast Transmission Electron Microscope with Picosecond Temporal Resolution and Nanometer Spatial Resolution

    OpenAIRE

    Xiang, D.; Fu, F.; Zhang, J.; Huang, X.; Wang, L.; Wang, X.; Wan, W.

    2014-01-01

    We present feasibility study of an accelerator-based ultrafast transmission electron microscope (u-TEM) capable of producing a full field image in a single-shot with simultaneous picosecond temporal resolution and nanometer spatial resolution. We study key physics related to performance of u-TEMs, and discuss major challenges as well as possible solutions for practical realization of u-TEMs. The feasibility of u-TEMs is confirmed through simulations using realistic electron beam parameters. W...

  14. Multishot versus single-shot pulse sequences in very high field fMRI: a comparison using retinotopic mapping.

    Directory of Open Access Journals (Sweden)

    Jascha D Swisher

    Full Text Available High-resolution functional MRI is a leading application for very high field (7 Tesla human MR imaging. Though higher field strengths promise improvements in signal-to-noise ratios (SNR and BOLD contrast relative to fMRI at 3 Tesla, these benefits may be partially offset by accompanying increases in geometric distortion and other off-resonance effects. Such effects may be especially pronounced with the single-shot EPI pulse sequences typically used for fMRI at standard field strengths. As an alternative, one might consider multishot pulse sequences, which may lead to somewhat lower temporal SNR than standard EPI, but which are also often substantially less susceptible to off-resonance effects. Here we consider retinotopic mapping of human visual cortex as a practical test case by which to compare examples of these sequence types for high-resolution fMRI at 7 Tesla. We performed polar angle retinotopic mapping at each of 3 isotropic resolutions (2.0, 1.7, and 1.1 mm using both accelerated single-shot 2D EPI and accelerated multishot 3D gradient-echo pulse sequences. We found that single-shot EPI indeed led to greater temporal SNR and contrast-to-noise ratios (CNR than the multishot sequences. However, additional distortion correction in postprocessing was required in order to fully realize these advantages, particularly at higher resolutions. The retinotopic maps produced by both sequence types were qualitatively comparable, and showed equivalent test/retest reliability. Thus, when surface-based analyses are planned, or in other circumstances where geometric distortion is of particular concern, multishot pulse sequences could provide a viable alternative to single-shot EPI.

  15. Single-shot echo-planar MR sequences in the diagnosis of intracranial infectious diseases

    International Nuclear Information System (INIS)

    Tsuchiya, Kazuhiro; Katase, Shichiro; Yoshino, Ayako; Yamakami, Norio; Hachiya, Junichi

    1998-01-01

    The purpose of this study was to present our preliminary experience in the application of echo-planar-imaging (EPI) MR sequences for the diagnosis of intracranial infectious diseases and to assess the value of these sequences. We reviewed single-shot EPI MR images obtained at 1.5 T in 17 patients and compared these images with conventional or fast spin-echo (SE) or fluid attenuated inversion-recovery (FLAIR) images. The clinical diagnoses for the 17 patients were meningitis (2 patients), encephalitis or meningoencephalitis (7 patients), brain abscess (5 patients), epidural empyema (2 patients) and Creutzfeldt-Jakob disease (1 patient). We obtained EPI-T 2 -weighted (T 2 W) images in 8 patients, EPI-FLAIR images in 13 patients and EPI-diffusion-weighted (DW) images in 14 patients. Among the 8 patients for whom EPI-T 2 W imaging was performed, EPI-T 2 W imaging yielded superior results compared with SE-T 2 W imaging in 3 patients as a consequence of patient motion and equal results compared with SE-T 2 W imaging in 5 patients. Among the 13 patients for whom EPI-FLAIR imaging was performed, the EPI-FLAIR images were superior to conventional FLAIR images in 3 unstable patients. In the remaining 10 patients for whom EPI-FLAIR imaging was performed, EPI-FLAIR images were equivalent or inferior to conventional FLAIR images. In 6 patients with encephalitis or meningoencephalitis, the encephalitic lesions showed hyperintensity in EPI-DW images to a greater extent than in images obtained with the other techniques. In 3 patients, EPI-DW images also demonstrated hyperintensity for the contents of abscesses or areas of empyema that was not seen with the other imaging techniques. The value of EPI-T 2 W and EPI-FLAIR imaging is limited in uncooperative patients. EPI-DW imaging was found to be of value for the evaluation of several intracranial infectious diseases. (author)

  16. Single-shot echo-planar MR sequences in the diagnosis of intracranial infectious diseases

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, Kazuhiro; Katase, Shichiro; Yoshino, Ayako; Yamakami, Norio; Hachiya, Junichi [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1998-06-01

    The purpose of this study was to present our preliminary experience in the application of echo-planar-imaging (EPI) MR sequences for the diagnosis of intracranial infectious diseases and to assess the value of these sequences. We reviewed single-shot EPI MR images obtained at 1.5 T in 17 patients and compared these images with conventional or fast spin-echo (SE) or fluid attenuated inversion-recovery (FLAIR) images. The clinical diagnoses for the 17 patients were meningitis (2 patients), encephalitis or meningoencephalitis (7 patients), brain abscess (5 patients), epidural empyema (2 patients) and Creutzfeldt-Jakob disease (1 patient). We obtained EPI-T{sub 2}-weighted (T{sub 2}W) images in 8 patients, EPI-FLAIR images in 13 patients and EPI-diffusion-weighted (DW) images in 14 patients. Among the 8 patients for whom EPI-T{sub 2}W imaging was performed, EPI-T{sub 2}W imaging yielded superior results compared with SE-T{sub 2}W imaging in 3 patients as a consequence of patient motion and equal results compared with SE-T{sub 2}W imaging in 5 patients. Among the 13 patients for whom EPI-FLAIR imaging was performed, the EPI-FLAIR images were superior to conventional FLAIR images in 3 unstable patients. In the remaining 10 patients for whom EPI-FLAIR imaging was performed, EPI-FLAIR images were equivalent or inferior to conventional FLAIR images. In 6 patients with encephalitis or meningoencephalitis, the encephalitic lesions showed hyperintensity in EPI-DW images to a greater extent than in images obtained with the other techniques. In 3 patients, EPI-DW images also demonstrated hyperintensity for the contents of abscesses or areas of empyema that was not seen with the other imaging techniques. The value of EPI-T{sub 2}W and EPI-FLAIR imaging is limited in uncooperative patients. EPI-DW imaging was found to be of value for the evaluation of several intracranial infectious diseases. (author)

  17. X-Ray Emission Spectrometer Design with Single-Shot Pump-Probe and Resonant Excitation Capabilities

    Energy Technology Data Exchange (ETDEWEB)

    Spoth, Katherine; /SUNY, Buffalo /SLAC

    2012-08-28

    Core-level spectroscopy in the soft X-ray regime is a powerful tool for the study of chemical bonding processes. The ultrafast, ultrabright X-ray pulses generated by the Linac Coherent Light Source (LCLS) allow these reactions to be studied in greater detail than ever before. In this study, we investigated a conceptual design of a spectrometer for the LCLS with imaging in the non-dispersive direction. This would allow single-shot collection of X-ray emission spectroscopy (XES) measurements with varying laser pump X-ray probe delay or a variation of incoming X-ray energy over the illuminated area of the sample. Ray-tracing simulations were used to demonstrate how the components of the spectrometer affect its performance, allowing a determination of the optimal final design. These simulations showed that the spectrometer's non-dispersive focusing is extremely sensitive to the size of the sample footprint; the spectrometer is not able to image a footprint width larger than one millimeter with the required resolution. This is compatible with a single shot scheme that maps out the laser pump X-ray probe delay in the non-dispersive direction as well as resonant XES applications at normal incidence. However, the current capabilities of the Soft X-Ray (SXR) beamline at the LCLS do not produce the required energy range in a small enough sample footprint, hindering the single shot resonant XES application at SXR for chemical dynamics studies at surfaces. If an upgraded or future beamline at LCLS is developed with lower monochromator energy dispersion the width can be made small enough at the required energy range to be imaged by this spectrometer design.

  18. A single-shot nonlinear autocorrelation approach for time-resolved physics in the vacuum ultraviolet spectral range

    International Nuclear Information System (INIS)

    Rompotis, Dimitrios

    2016-02-01

    In this work, a single-shot temporal metrology scheme operating in the vacuum-extreme ultraviolet spectral range has been designed and experimentally implemented. Utilizing an anti-collinear geometry, a second-order intensity autocorrelation measurement of a vacuum ultraviolet pulse can be performed by encoding temporal delay information on the beam propagation coordinate. An ion-imaging time-of-flight spectrometer, offering micrometer resolution has been set-up for this purpose. This instrument enables the detection of a magnified image of the spatial distribution of ions exclusively generated by direct two-photon absorption in the combined counter-propagating pulse focus and thus obtain the second-order intensity autocorrelation measurement on a single-shot basis. Additionally, an intense VUV light source based on high-harmonic generation has been experimentally realized. It delivers intense sub-20 fs Ti:Sa fifth-harmonic pulses utilizing a loose-focusing geometry in a long Ar gas cell. The VUV pulses centered at 161.8 nm reach pulse energies of 1.1 μJ per pulse, while the corresponding pulse duration is measured with a second-order, fringe-resolved autocorrelation scheme to be 18 ± 1 fs on average. Non-resonant, two-photon ionization of Kr and Xe and three-photon ionization of Ne verify the fifth-harmonic pulse intensity and indicate the feasibility of multi-photon VUV pump/VUV probe studies of ultrafast atomic and molecular dynamics. Finally, the extended functionally of the counter-propagating pulse metrology approach is demonstrated by a single-shot VUV pump/VUV probe experiment aiming at the investigation of ultrafast dissociation dynamics of O 2 excited in the Schumann-Runge continuum at 162 nm.

  19. Simultaneous single-shot readout of multi-qubit circuits using a traveling-wave parametric amplifier

    Science.gov (United States)

    O'Brien, Kevin

    Observing and controlling the state of ever larger quantum systems is critical for advancing quantum computation. Utilizing a Josephson traveling wave parametric amplifier (JTWPA), we demonstrate simultaneous multiplexed single shot readout of 10 transmon qubits in a planar architecture. We employ digital image sideband rejection to eliminate noise at the image frequencies. We quantify crosstalk and infidelity due to simultaneous readout and control of multiple qubits. Based on current amplifier technology, this approach can scale to simultaneous readout of at least 20 qubits. This work was supported by the Army Research Office.

  20. Real time quantitative phase microscopy based on single-shot transport of intensity equation (ssTIE) method

    Science.gov (United States)

    Yu, Wei; Tian, Xiaolin; He, Xiaoliang; Song, Xiaojun; Xue, Liang; Liu, Cheng; Wang, Shouyu

    2016-08-01

    Microscopy based on transport of intensity equation provides quantitative phase distributions which opens another perspective for cellular observations. However, it requires multi-focal image capturing while mechanical and electrical scanning limits its real time capacity in sample detections. Here, in order to break through this restriction, real time quantitative phase microscopy based on single-shot transport of the intensity equation method is proposed. A programmed phase mask is designed to realize simultaneous multi-focal image recording without any scanning; thus, phase distributions can be quantitatively retrieved in real time. It is believed the proposed method can be potentially applied in various biological and medical applications, especially for live cell imaging.

  1. Single shot fringe pattern phase demodulation using Hilbert-Huang transform aided by the principal component analysis.

    Science.gov (United States)

    Trusiak, Maciej; Służewski, Łukasz; Patorski, Krzysztof

    2016-02-22

    Hybrid single shot algorithm for accurate phase demodulation of complex fringe patterns is proposed. It employs empirical mode decomposition based adaptive fringe pattern enhancement (i.e., denoising, background removal and amplitude normalization) and subsequent boosted phase demodulation using 2D Hilbert spiral transform aided by the Principal Component Analysis method for novel, correct and accurate local fringe direction map calculation. Robustness to fringe pattern significant noise, uneven background and amplitude modulation as well as local fringe period and shape variations is corroborated by numerical simulations and experiments. Proposed automatic, adaptive, fast and comprehensive fringe analysis solution compares favorably with other previously reported techniques.

  2. Femtosecond Single-Shot Imaging of Nanoscale Ferromagnetic Order in Co/Pd Multilayers using Resonant X-ray Holography

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Tianhan; Zhu, Diling; Benny Wu,; Graves, Catherine; Schaffert, Stefan; Rander, Torbjorn; Muller, leonard; Vodungbo, Boris; Baumier, Cedric; Bernstein, David P.; Brauer, Bjorn; Cros, Vincent; Jong, Sanne de; Delaunay, Renaud; Fognini, Andreas; Kukreja, Roopali; Lee, Sooheyong; Lopez-Flores, Victor; Mohanty, Jyoti; Pfau, Bastian; Popescu, 5 Horia

    2012-05-15

    We present the first single-shot images of ferromagnetic, nanoscale spin order taken with femtosecond x-ray pulses. X-ray-induced electron and spin dynamics can be outrun with pulses shorter than 80 fs in the investigated fluence regime, and no permanent aftereffects in the samples are observed below a fluence of 25 mJ/cm{sup 2}. Employing resonant spatially-muliplexed x-ray holography results in a low imaging threshold of 5 mJ/cm{sup 2}. Our results open new ways to combine ultrafast laser spectroscopy with sequential snapshot imaging on a single sample, generating a movie of excited state dynamics.

  3. Accelerator-based single-shot ultrafast transmission electron microscope with picosecond temporal resolution and nanometer spatial resolution

    Science.gov (United States)

    Xiang, D.; Fu, F.; Zhang, J.; Huang, X.; Wang, L.; Wang, X.; Wan, W.

    2014-09-01

    We present feasibility study of an accelerator-based ultrafast transmission electron microscope (u-TEM) capable of producing a full field image in a single-shot with simultaneous picosecond temporal resolution and nanometer spatial resolution. We study key physics related to performance of u-TEMs and discuss major challenges as well as possible solutions for practical realization of u-TEMs. The feasibility of u-TEMs is confirmed through simulations using realistic electron beam parameters. We anticipate that u-TEMs with a product of temporal and spatial resolution beyond 10-19 ms will open up new opportunities in probing matter at ultrafast temporal and ultrasmall spatial scales.

  4. Urinary retention in unilateral total knee arthroplasty: comparison between continuous epidural analgesia and single-shot femoral nerve block

    International Nuclear Information System (INIS)

    Khan, A.A.; Khan, R.I.

    2018-01-01

    To compare the frequency of urinary retention and requirement of bladder catheterization in patients undergoing toatal knee arthroplasty while receiving either continuous epidural analgesia or single-shot femoral nerve block. Study Design: Randomized controlled study. Place and Duration of Study:Operating Rooms of Aga Khan University Hospital, Karachi, from January 2014 to January 2015. Methodology:Patients were randomized in two groups of 30 each, i.e. epidural group (group E) or femoral nerve block group (group F). Baseline parameters were recorded. Postoperatively, patients were followed for upto 24 hours to collect the data regarding urinary retention. Final outcome was taken at 24 hours postoperatively. Data was analyzed to compare the frequency of urinary retention between the two groups. Results:The average age of the patients was 59.58 +-5.85 years. There were 28 (46.7%) male and 32 (53.3%) female patients. Frequency of urinary retention was significantly high in Group E than Group F (46.7% vs. 6.7%; p=0.0005). Conclusion: Single-shot femoral nerve block offers a more favorable profile in terms of postoperative urinary retention when compared to continuous epidural analgesia. (author)

  5. Development and Characterization of Two-Dimensional Gratings for Single-Shot X-ray Phase-Contrast Imaging

    Directory of Open Access Journals (Sweden)

    Margarita Zakharova

    2018-03-01

    Full Text Available Single-shot grating-based phase-contrast imaging techniques offer additional contrast modalities based on the refraction and scattering of X-rays in a robust and versatile configuration. The utilization of a single optical element is possible in such methods, allowing the shortening of the acquisition time and increasing flux efficiency. One of the ways to upgrade single-shot imaging techniques is to utilize customized optical components, such as two-dimensional (2D X-ray gratings. In this contribution, we present the achievements in the development of 2D gratings with UV lithography and gold electroplating. Absorption gratings represented by periodic free-standing gold pillars with lateral structure sizes from 5 µm to 25 µm and heights from 5 µm to 28 µm have shown a high degree of periodicity and defect-free patterns. Grating performance was tested in a radiographic setup using a self-developed quality assessment algorithm based on the intensity distribution histograms. The algorithm allows the final user to estimate the suitability of a specific grating to be used in a particular setup.

  6. Optimization of laser energy deposition for single-shot high aspect-ratio microstructuring of thick BK7 glass

    Energy Technology Data Exchange (ETDEWEB)

    Garzillo, Valerio; Grigutis, Robertas [Dipartimento di Scienza e Alta Tecnologia, University of Insubria, Via Valleggio 11, I-22100 Como (Italy); Jukna, Vytautas [Centre de Physique Theorique, CNRS, Ecole Polytechnique, Université Paris-Saclay, F-91128 Palaiseau (France); LOA, ENSTA-ParisTech, CNRS, Ecole Polytechnique, Université Paris Saclay, F-91762 Palaiseau (France); Couairon, Arnaud [Centre de Physique Theorique, CNRS, Ecole Polytechnique, Université Paris-Saclay, F-91128 Palaiseau (France); Di Trapani, Paolo [Dipartimento di Scienza e Alta Tecnologia, University of Insubria and CNISM UdR Como, Via Valleggio 11, I-22100 Como (Italy); Jedrkiewicz, Ottavia, E-mail: ottavia.jedrkiewicz@ifn.cnr.it [Istituto di Fotonica e Nanotecnologie, CNR and CNISM UdR Como, Via Valleggio 11, I-22100 Como (Italy)

    2016-07-07

    We investigate the generation of high aspect ratio microstructures across 0.7 mm thick glass by means of single shot Bessel beam laser direct writing. We study the effect on the photoinscription of the cone angle, as well as of the energy and duration of the ultrashort laser pulse. The aim of the study is to optimize the parameters for the writing of a regular microstructure due to index modification along the whole sample thickness. By using a spectrally resolved single pulse transmission diagnostics at the output surface of the glass, we correlate the single shot material modification with observations of the absorption in different portions of the retrieved spectra, and with the absence or presence of spectral modulation. Numerical simulations of the evolution of the Bessel pulse intensity and of the energy deposition inside the sample help us interpret the experimental results that suggest to use picosecond pulses for an efficient and more regular energy deposition. Picosecond pulses take advantage of nonlinear plasma absorption and avoid temporal dynamics effects which can compromise the stationarity of the Bessel beam propagation.

  7. Single-shot imaging with higher-dimensional encoding using magnetic field monitoring and concomitant field correction.

    Science.gov (United States)

    Testud, Frederik; Gallichan, Daniel; Layton, Kelvin J; Barmet, Christoph; Welz, Anna M; Dewdney, Andrew; Cocosco, Chris A; Pruessmann, Klaas P; Hennig, Jürgen; Zaitsev, Maxim

    2015-03-01

    PatLoc (Parallel Imaging Technique using Localized Gradients) accelerates imaging and introduces a resolution variation across the field-of-view. Higher-dimensional encoding employs more spatial encoding magnetic fields (SEMs) than the corresponding image dimensionality requires, e.g. by applying two quadratic and two linear spatial encoding magnetic fields to reconstruct a 2D image. Images acquired with higher-dimensional single-shot trajectories can exhibit strong artifacts and geometric distortions. In this work, the source of these artifacts is analyzed and a reliable correction strategy is derived. A dynamic field camera was built for encoding field calibration. Concomitant fields of linear and nonlinear spatial encoding magnetic fields were analyzed. A combined basis consisting of spherical harmonics and concomitant terms was proposed and used for encoding field calibration and image reconstruction. A good agreement between the analytical solution for the concomitant fields and the magnetic field simulations of the custom-built PatLoc SEM coil was observed. Substantial image quality improvements were obtained using a dynamic field camera for encoding field calibration combined with the proposed combined basis. The importance of trajectory calibration for single-shot higher-dimensional encoding is demonstrated using the combined basis including spherical harmonics and concomitant terms, which treats the concomitant fields as an integral part of the encoding. © 2014 Wiley Periodicals, Inc.

  8. Single-shot full resolution region-of-interest (ROI) reconstruction in image plane digital holographic microscopy

    Science.gov (United States)

    Singh, Mandeep; Khare, Kedar

    2018-05-01

    We describe a numerical processing technique that allows single-shot region-of-interest (ROI) reconstruction in image plane digital holographic microscopy with full pixel resolution. The ROI reconstruction is modelled as an optimization problem where the cost function to be minimized consists of an L2-norm squared data fitting term and a modified Huber penalty term that are minimized alternately in an adaptive fashion. The technique can provide full pixel resolution complex-valued images of the selected ROI which is not possible to achieve with the commonly used Fourier transform method. The technique can facilitate holographic reconstruction of individual cells of interest from a large field-of-view digital holographic microscopy data. The complementary phase information in addition to the usual absorption information already available in the form of bright field microscopy can make the methodology attractive to the biomedical user community.

  9. Single-shot spectro-temporal characterization of XUV pulses from a seeded free-electron laser

    Science.gov (United States)

    de Ninno, Giovanni; Gauthier, David; Mahieu, Benoît; Ribič, Primož Rebernik; Allaria, Enrico; Cinquegrana, Paolo; Danailov, Miltcho Bojanov; Demidovich, Alexander; Ferrari, Eugenio; Giannessi, Luca; Penco, Giuseppe; Sigalotti, Paolo; Stupar, Matija

    2015-08-01

    Intense ultrashort X-ray pulses produced by modern free-electron lasers (FELs) allow one to probe biological systems, inorganic materials and molecular reaction dynamics with nanoscale spatial and femtoscale temporal resolution. These experiments require the knowledge, and possibly the control, of the spectro-temporal content of individual pulses. FELs relying on seeding have the potential to produce spatially and temporally fully coherent pulses. Here we propose and implement an interferometric method, which allows us to carry out the first complete single-shot spectro-temporal characterization of the pulses, generated by an FEL in the extreme ultraviolet spectral range. Moreover, we provide the first direct evidence of the temporal coherence of a seeded FEL working in the extreme ultraviolet spectral range and show the way to control the light generation process to produce Fourier-limited pulses. Experiments are carried out at the FERMI FEL in Trieste.

  10. Single-shot mega-electronvolt ultrafast electron diffraction for structure dynamic studies of warm dense matter

    Energy Technology Data Exchange (ETDEWEB)

    Mo, M. Z., E-mail: mmo09@slac.stanford.edu; Shen, X.; Chen, Z.; Li, R. K.; Dunning, M.; Zheng, Q.; Weathersby, S. P.; Reid, A. H.; Coffee, R.; Makasyuk, I.; Edstrom, S.; McCormick, D.; Jobe, K.; Hast, C.; Glenzer, S. H.; Wang, X. [SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Sokolowski-Tinten, K. [Faculty of Physics and Centre for Nanointegration Duisburg-Essen, University of Duisburg-Essen, Lotharstrasse 1, D-47048 Duisburg (Germany)

    2016-11-15

    We have developed a single-shot mega-electronvolt ultrafast-electron-diffraction system to measure the structural dynamics of warm dense matter. The electron probe in this system is featured by a kinetic energy of 3.2 MeV and a total charge of 20 fC, with the FWHM pulse duration and spot size at sample of 350 fs and 120 μm respectively. We demonstrate its unique capability by visualizing the atomic structural changes of warm dense gold formed from a laser-excited 35-nm freestanding single-crystal gold foil. The temporal evolution of the Bragg peak intensity and of the liquid signal during solid-liquid phase transition are quantitatively determined. This experimental capability opens up an exciting opportunity to unravel the atomic dynamics of structural phase transitions in warm dense matter regime.

  11. Value of selective MIP reconstructions of respiratory triggered 3D-TSE-MR cholangiography on a workstation versus standard MIP reconstructions and single-shot MRCP

    International Nuclear Information System (INIS)

    Schaible, R.; Textor, J.; Kreft, B.; Schild, H.; Neubrand, M.

    2001-01-01

    Comparison of anatomical visualisation and diagnostic value of selective MIP reconstructions of respiratory triggered 3D-TSE-MRCP versus standard MIP reconstructions and single-shot MRCP. Material and Methods: 50 patients with pancreaticobiliary disease were examined at 1.5 Tesla (ACS NT II, Philips Medical Systems) using a breath-hold single-shot (SS) and a respiratory triggered 3D-TSE-MRCP technique in 12 standard MIP projections. Additional selective MIP reconstructions with different slice thickness (2, 4, 10 cm) and projections were performed on a workstation. Visualization of the pancreaticobiliary system and the diagnostic value of the examinations were analysed. Results: Single-shot and 3D-TSE in standard projections showed comparable anatomical visualisation. On selective MIP reconstructions the biliary system (SS p [de

  12. Clinical application of Half Fourier Acquisition Single Shot Turbo Spin Echo (HASTE) imaging accelerated by simultaneous multi-slice acquisition.

    Science.gov (United States)

    Schulz, Jenni; P Marques, José; Ter Telgte, Annemieke; van Dorst, Anouk; de Leeuw, Frank-Erik; Meijer, Frederick J A; Norris, David G

    2018-01-01

    As a single-shot sequence with a long train of refocusing pulses, Half-Fourier Acquisition Single-Shot Turbo-Spin-Echo (HASTE) suffers from high power deposition limiting use at high resolutions and high field strengths, particularly if combined with acceleration techniques such as simultaneous multi-slice (SMS) imaging. Using a combination of multiband (MB)-excitation and PINS-refocusing pulses will effectively accelerate the acquisition time while staying within the SAR limitations. In particular, uncooperative and young patients will profit from the speed of the MB-PINS HASTE sequence, as clinical diagnosis can be possible without sedation. Materials and MethodsMB-excitation and PINS-refocusing pulses were incorporated into a HASTE-sequence with blipped CAIPIRINHA and TRAPS including an internal FLASH reference scan for online reconstruction. Whole brain MB-PINS HASTE data were acquired on a Siemens 3T-Prisma system from 10 individuals and compared to a clinical HASTE protocol. ResultsThe proposed MB-PINS HASTE protocol accelerates the acquisition by about a factor 2 compared to the clinical HASTE. The diagnostic image quality proved to be comparable for both sequences for the evaluation of the overall aspect of the brain, the detection of white matter changes and areas of tissue loss, and for the evaluation of the CSF spaces although artifacts were more frequently encountered with MB-PINS HASTE. ConclusionsMB-PINS HASTE enables acquisition of slice accelerated highly T2-weighted images and provides good diagnostic image quality while reducing acquisition time. Copyright © 2017 Elsevier B.V. All rights reserved.

  13. Single-shot antithymocyte globulin (ATG) induction for pancreas/kidney transplantation: ATG-Fresenius versus Thymoglobulin.

    Science.gov (United States)

    Schulz, T; Papapostolou, G; Schenker, P; Kapischke, M

    2005-03-01

    Single-shot antithymocyte globulin (ATG) prior to reperfusion followed by tacrolimus (TAC), mycophenolate mofetil (MMF), and prednisolone (PRD) is an established induction therapy in simultaneous pancreas kidney transplant (SPK) recipients. We retrospectively analyzed 6-month data from 105 patients who received their first SPK. From January 1996 to December 2000, ATG-Fresenius was used. Since January 2001, Thymoglobulin has been administered. In the first group, 58 patients were treated with ATG-Fresenius (4-6 mg/kg body weight). In the second group, 47 patients received Thymoglobulin (1.5-2.5 mg/kg body weight). HLA-mismatch was comparable. After an observation period of 6 months, patients, kidney, and pancreas graft survival is 98.3%, 96.6%, and 93.1% in group I and 97.9%, 97.9%, and 85.1% in group II, respectively. In each group, one death with functioning graft (DWFG) was observed. Twenty (34.5%) acute rejection episodes (AR) were observed (18 patients) in group I. They were treated with steroids (n = 16) or steroids/OKT3 (n = 4). One kidney graft failure was observed due to rejection and one due to DWFG. Four pancreas grafts were lost (thrombosis, n = 2; AR, n = 1; DWFG, n = 1). In group II, 15 AR (31.9%) were seen in 12 patients and were treated with steroids (n = 12), steroids/ATG (n = 1), or steroids/OKT3 (n = 2). Seven pancreas (thrombosis, n = 5; rejection, n = 1; DWFG, n = 1) and one kidney (DWFG, n = 1) graft losses occurred. These data clearly establish that single-shot ATG prior to reperfusion, followed by TAC, MMF, and PRD results in a low incidence of AR (34.5% in group I and 31.9% in group II) after SPK. Only 6.9% (group I) and 6.4% (group II) of the patients received antibodies for rejection treatment.

  14. High-speed single-shot optical focusing through dynamic scattering media with full-phase wavefront shaping

    Science.gov (United States)

    Hemphill, Ashton S.; Shen, Yuecheng; Liu, Yan; Wang, Lihong V.

    2017-11-01

    In biological applications, optical focusing is limited by the diffusion of light, which prevents focusing at depths greater than ˜1 mm in soft tissue. Wavefront shaping extends the depth by compensating for phase distortions induced by scattering and thus allows for focusing light through biological tissue beyond the optical diffusion limit by using constructive interference. However, due to physiological motion, light scattering in tissue is deterministic only within a brief speckle correlation time. In in vivo tissue, this speckle correlation time is on the order of milliseconds, and so the wavefront must be optimized within this brief period. The speed of digital wavefront shaping has typically been limited by the relatively long time required to measure and display the optimal phase pattern. This limitation stems from the low speeds of cameras, data transfer and processing, and spatial light modulators. While binary-phase modulation requiring only two images for the phase measurement has recently been reported, most techniques require at least three frames for the full-phase measurement. Here, we present a full-phase digital optical phase conjugation method based on off-axis holography for single-shot optical focusing through scattering media. By using off-axis holography in conjunction with graphics processing unit based processing, we take advantage of the single-shot full-phase measurement while using parallel computation to quickly reconstruct the phase map. With this system, we can focus light through scattering media with a system latency of approximately 9 ms, on the order of the in vivo speckle correlation time.

  15. Characterization of temporal coherence of hard X-ray free-electron laser pulses with single-shot interferograms

    Directory of Open Access Journals (Sweden)

    Taito Osaka

    2017-11-01

    Full Text Available Temporal coherence is one of the most fundamental characteristics of light, connecting to spectral information through the Fourier transform relationship between time and frequency. Interferometers with a variable path-length difference (PLD between the two branches have widely been employed to characterize temporal coherence properties for broad spectral regimes. Hard X-ray interferometers reported previously, however, have strict limitations in their operational photon energies, due to the specific optical layouts utilized to satisfy the stringent requirement for extreme stability of the PLD at sub-ångström scales. The work presented here characterizes the temporal coherence of hard X-ray free-electron laser (XFEL pulses by capturing single-shot interferograms. Since the stability requirement is drastically relieved with this approach, it was possible to build a versatile hard X-ray interferometer composed of six separate optical elements to cover a wide photon energy range from 6.5 to 11.5 keV while providing a large variable delay time of up to 47 ps at 10 keV. A high visibility of up to 0.55 was observed at a photon energy of 10 keV. The visibility measurement as a function of time delay reveals a mean coherence time of 5.9 ± 0.7 fs, which agrees with that expected from the single-shot spectral information. This is the first result of characterizing the temporal coherence of XFEL pulses in the hard X-ray regime and is an important milestone towards ultra-high energy resolutions at micro-electronvolt levels in time-domain X-ray spectroscopy, which will open up new opportunities for revealing dynamic properties in diverse systems on timescales from femtoseconds to nanoseconds, associated with fluctuations from ångström to nanometre spatial scales.

  16. Diffusion-weighted single shot echo planar imaging of colorectal cancer using a sensitivity-encoding technique

    International Nuclear Information System (INIS)

    Nasu, Katsuhiro; Kuroki, Yoshihumi; Murakami, Koji; Nawano, Shigeru; Kuroki, Seiko; Moriyama, Noriyuki

    2004-01-01

    We wanted to determine the feasibility of diffusion-weighted single shot echo planar imaging using a sensitivity encoding diffusion weighted imaging (SENSE-DWI) technique in depicting colorectal cancer. Forty-two patients with sigmoid colon cancer and rectal cancer, all proven pathologically, were examined on T2-turbo spin echo (TSE) and SENSE-DWI. No bowel preparation was performed before examination. The b-factors used in SENSE-DWI were zero and 1000 s/mm 2 . In 10 randomly selected cases, the images whose b-factors were 250 and 500 s/mm 2 were also obtained. The reduction factor of SENSE was 2.0 in all sequences. Two radiologists evaluated the obtained images from the viewpoints of tumor detectability, image distortion and misregistration of the tumors. The apparent diffusion coefficients (ADCs) of the tumors and urine in the urinary bladders in each patient were measured to evaluate the correlation between ADC and pathological classification of each tumor. All tumors were depicted hyperintensely on SENSE-DWI. Even though single shot echo planar imaging (EPI) was used, the image distortion and misregistration was quite pronounced because of simultaneous use of SENSE. On SENSE-DWI whose b-factor was 1000 s/mm 2 , the normal colon wall and feces were always hypointense and easily differentiated from the tumors. The mean ADC value of each tumor was 1.02±0.1 (x 10 -3 ) mm 2 /s. No overt correlation can be pointed out between ADC and pathological classification of each tumor. SENSE-DWI is a feasible method for depicting colorectal cancer. SENSE-DWI provides strong contrast among colorectal cancers, normal rectal wall and feces. (authors)

  17. Ankle Block vs Single-Shot Popliteal Fossa Block as Primary Anesthesia for Forefoot Operative Procedures: Prospective, Randomized Comparison.

    Science.gov (United States)

    Schipper, Oliver N; Hunt, Kenneth J; Anderson, Robert B; Davis, W Hodges; Jones, Carroll P; Cohen, Bruce E

    2017-11-01

    Postoperative pain is often difficult to control with oral medications, requiring large doses of opioid analgesia. Regional anesthesia may be used for primary anesthesia, reducing the need for general anesthetic and postoperative pain medication requirements in the immediate postoperative period. The purpose of this study was to compare the analgesic effects of an ankle block (AB) to a single-shot popliteal fossa block (PFB) for patients undergoing orthopedic forefoot procedures. All patients having elective outpatient orthopedic forefoot procedures were invited to participate in the study. Patients were prospectively randomized to receive either an ultrasound-guided AB or PFB by a board-certified anesthesiologist prior to their procedure. Intraoperative conversion to general anesthesia and postanesthesia care unit (PACU) opioid requirements were recorded. Postoperative pain was assessed using the visual analog scale (VAS) at regular time intervals until 8 am on postoperative day (POD) 2. Patients rated the effectiveness of the block on a 1 to 5 scale, with 5 being very effective. A total of 167 patients participated in the study with 88 patients (53%) receiving an AB and 79 (47%) receiving a single-shot PFB. There was no significant difference in the rate of conversion to general anesthesia between the 2 groups (13.6% [12/88] AB vs 12.7% [10/79] PFB). PACU morphine requirements and doses were significantly reduced in the PFB group ( P = .004) when compared to the AB group. The VAS was also significantly lower for the PFB patients at 10 pm on POD 0 (4.6 vs 1.6, P block site pain and/or erythema (AB 6.9% [6/88] vs PFB 5.1% [4/79], P = .44). The analgesic effect of the PFB lasted significantly longer when compared to the ankle block (AB 14.5 hours vs PFB 20.9 hours, P block between the 2 groups, with both blocks being highly effective (AB 4.79/5 vs PFB 4.82/5, P = .68). Regional anesthesia was a safe and reliable adjunct to perioperative pain management and highly

  18. Silicon-Vacancy Spin Qubit in Diamond: A Quantum Memory Exceeding 10 ms with Single-Shot State Readout

    Science.gov (United States)

    Sukachev, D. D.; Sipahigil, A.; Nguyen, C. T.; Bhaskar, M. K.; Evans, R. E.; Jelezko, F.; Lukin, M. D.

    2017-12-01

    The negatively charged silicon-vacancy (SiV- ) color center in diamond has recently emerged as a promising system for quantum photonics. Its symmetry-protected optical transitions enable the creation of indistinguishable emitter arrays and deterministic coupling to nanophotonic devices. Despite this, the longest coherence time associated with its electronic spin achieved to date (˜250 ns ) has been limited by coupling to acoustic phonons. We demonstrate coherent control and suppression of phonon-induced dephasing of the SiV- electronic spin coherence by 5 orders of magnitude by operating at temperatures below 500 mK. By aligning the magnetic field along the SiV- symmetry axis, we demonstrate spin-conserving optical transitions and single-shot readout of the SiV- spin with 89% fidelity. Coherent control of the SiV- spin with microwave fields is used to demonstrate a spin coherence time T2 of 13 ms and a spin relaxation time T1 exceeding 1 s at 100 mK. These results establish the SiV- as a promising solid-state candidate for the realization of quantum networks.

  19. Flexible Low-power SiGe HBT Amplifier Circuits for Fast Single-shot Spin Readout

    Science.gov (United States)

    England, Troy; Lilly, Michael; Curry, Matthew; Carr, Stephen; Carroll, Malcolm

    Fast, low-power quantum state readout is one of many challenges facing quantum information processing. Single electron transistors (SETs) are potentially fast, sensitive detectors for performing spin readout of electrons bound to Si:P donors. From a circuit perspective, however, their output impedance and nonlinear conductance are ill suited to drive the parasitic capacitance of coaxial conductors used in cryogenic environments, necessitating a cryogenic amplification stage. We will introduce two new amplifier topologies that provide excellent gain versus power tradeoffs using silicon-germanium (SiGe) heterojunction bipolar transistors (HBTs). The AC HBT allows in-situ adjustment of power dissipation during an experiment and can provide gain in the millikelvin temperature regime while dissipating less than 500 nW. The AC Current Amplifier maximizes gain at nearly 800 A/A. We will also show results of using these amplifiers with SETs at 4 K. This work was performed, in part, at the Center for Integrated Nanotechnologies, a U.S. DOE Office of Basic Energy Sciences user facility. Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a Lockheed-Martin Company, for the U. S. Department of Energy under Contract No. DE-AC04-94AL85000. Flexible Low-power SiGe HBT Amplifier Circuits for Fast Single-shot Spin Readout.

  20. Single-shot T2 mapping using overlapping-echo detachment planar imaging and a deep convolutional neural network.

    Science.gov (United States)

    Cai, Congbo; Wang, Chao; Zeng, Yiqing; Cai, Shuhui; Liang, Dong; Wu, Yawen; Chen, Zhong; Ding, Xinghao; Zhong, Jianhui

    2018-04-24

    An end-to-end deep convolutional neural network (CNN) based on deep residual network (ResNet) was proposed to efficiently reconstruct reliable T 2 mapping from single-shot overlapping-echo detachment (OLED) planar imaging. The training dataset was obtained from simulations that were carried out on SPROM (Simulation with PRoduct Operator Matrix) software developed by our group. The relationship between the original OLED image containing two echo signals and the corresponding T 2 mapping was learned by ResNet training. After the ResNet was trained, it was applied to reconstruct the T 2 mapping from simulation and in vivo human brain data. Although the ResNet was trained entirely on simulated data, the trained network was generalized well to real human brain data. The results from simulation and in vivo human brain experiments show that the proposed method significantly outperforms the echo-detachment-based method. Reliable T 2 mapping with higher accuracy is achieved within 30 ms after the network has been trained, while the echo-detachment-based OLED reconstruction method took approximately 2 min. The proposed method will facilitate real-time dynamic and quantitative MR imaging via OLED sequence, and deep convolutional neural network has the potential to reconstruct maps from complex MRI sequences efficiently. © 2018 International Society for Magnetic Resonance in Medicine.

  1. Single-shot quantum nondemolition measurement of a quantum-dot electron spin using cavity exciton-polaritons

    Science.gov (United States)

    Puri, Shruti; McMahon, Peter L.; Yamamoto, Yoshihisa

    2014-10-01

    We propose a scheme to perform single-shot quantum nondemolition (QND) readout of the spin of an electron trapped in a semiconductor quantum dot (QD). Our proposal relies on the interaction of the QD electron spin with optically excited, quantum well (QW) microcavity exciton-polaritons. The spin-dependent Coulomb exchange interaction between the QD electron and cavity polaritons causes the phase and intensity response of left circularly polarized light to be different than that of right circularly polarized light, in such a way that the QD electron's spin can be inferred from the response to a linearly polarized probe reflected or transmitted from the cavity. We show that with careful device design it is possible to essentially eliminate spin-flip Raman transitions. Thus a QND measurement of the QD electron spin can be performed within a few tens of nanoseconds with fidelity ˜99.95%. This improves upon current optical QD spin readout techniques across multiple metrics, including speed and scalability.

  2. Cavity Exciton-Polariton mediated, Single-Shot Quantum Non-Demolition measurement of a Quantum Dot Electron Spin

    Science.gov (United States)

    Puri, Shruti; McMahon, Peter; Yamamoto, Yoshihisa

    2014-03-01

    The quantum non-demolition (QND) measurement of a single electron spin is of great importance in measurement-based quantum computing schemes. The current single-shot readout demonstrations exhibit substantial spin-flip backaction. We propose a QND readout scheme for quantum dot (QD) electron spins in Faraday geometry, which differs from previous proposals and implementations in that it relies on a novel physical mechanism: the spin-dependent Coulomb exchange interaction between a QD spin and optically-excited quantum well (QW) microcavity exciton-polaritons. The Coulomb exchange interaction causes a spin-dependent shift in the resonance energy of the polarized polaritons, thus causing the phase and intensity response of left circularly polarized light to be different to that of the right circularly polarized light. As a result the QD electron's spin can be inferred from the response to a linearly polarized probe. We show that by a careful design of the system, any spin-flip backaction can be eliminated and a QND measurement of the QD electron spin can be performed within a few 10's of nanoseconds with fidelity 99:95%. This improves upon current optical QD spin readout techniques across multiple metrics, including fidelity, speed and scalability. National Institute of Informatics, 2-1-2 Hitotsubashi, Chiyoda-ku, Tokyo 101-8430, Japan.

  3. MR imaging of the gastrointestinal tract with half-fourier single-shot fast spin echo (SSFSE)

    International Nuclear Information System (INIS)

    Boku, Houjun; Takehara, Yasuo; Isoda, Haruo; Isogai, Satoshi; Kaneko, Masao

    1999-01-01

    Our objective was to implement a non-invasive magnetic resonance imaging (MRI) technique combined with concentrated milk ingestion for depicting the gastrointestinal (GI) tract and detecting gastrointestinal motility and transit. The half-Fourier SSFSE (single-shot fast spin echo) sequence was optimized on the basis of a phantom study. In order to determine the feasibility of milk ingestion as a substitute for contrast medium, ten human volunteers were examined with SSFSE after two types of liquid ingestion (i.e., milk and water). The snapshot images provided subsecond data acquisition for each coronal plane, allowing visualization of peristalsis in the gastrointestinal tract in an almost real-time fashion, without motion-related image degradation, as would normally be seen using conventional MRI. There was no significant difference between concentrated milk and water in terms of depiction of the upper gastrointestinal tract; however, 10 min and 30 min after ingestion, concentrated milk showed better delineation of the intestine than that observed after water ingestion (p<0.01). MR gastrointestinal imaging is a non-invasive method that allows gastrointestinal depiction as well as analysis of motility and passage. Especially with concentrated milk ingestion, the distal intestines were well depicted with adequate contrast filling and distention. (author)

  4. Real-Time, Single-Shot Temporal Measurements of Short Electron Bunches, Terahertz CSR and FEL Radiation

    CERN Document Server

    Berden, G; Van der Meer, A F G

    2005-01-01

    Electro-optic detection of the Coulomb field of electron bunches is a promising technique for single-shot measurements of the bunch length and shape in the sub-picosecond time domain. This technique has been applied to the measurement of 50 MeV electron bunches in the FELIX free electron laser, showing the longitudinal profile of single bunches of around 650 fs FWHM [Phys. Rev. Lett. 93, 114802 (2004)]. The method is non-destructive and real-time, and therefore ideal for online monitoring of the longitudinal shape of single electron bunches. At FELIX we have used it for real-time optimization of sub-picosecond electron bunches. Electro-optic detection has also been used to measure the electric field profiles of far-infrared (or terahertz) optical pulses generated by the relativistic electrons. We have characterised the far-infrared output of the free electron laser, and more recently, we have measured the temporal profile of terahertz optical pulses generated at one of the bending magnets.

  5. Single-shot T1 mapping of the corpus callosum: A rapid characterization of fiber bundle anatomy

    Directory of Open Access Journals (Sweden)

    Sabine eHofer

    2015-05-01

    Full Text Available Using diffusion-tensor MRI and fiber tractography the topographic organization of the corpus callosum (CC has been described to comprise 5 segments with fibers projecting into prefrontal (I, premotor and supplementary motor (II, primary motor (III, and primary sensory areas (IV, as well as into parietal, temporal, and occipital cortical areas (V. In order to more rapidly characterize the underlying anatomy of these segments, this study used a novel single-shot T1 mapping method to quantitatively determine T1 relaxation times in the human CC. A region-of-interest analysis revealed a tendency for the lowest T1 relaxation times in the genu and the highest T1 relaxation times in the somatomotor region of the CC. This observation separates regions dominated by myelinated fibers with large diameters (somatomotor area from densely packed smaller axonal bundles (genu with less myelin. The results indicate that characteristic T1 relaxation times in callosal profiles provide an additional means to monitor differences in fiber anatomy, fiber density, and gray matter in respective neocortical areas. In conclusion, rapid T1 mapping allows for a characterization of the axonal architecture in an individual CC in less than 10 s. The approach emerges as a valuable means for studying neocortical brain anatomy with possible implications for the diagnosis of neurodegenerative processes.

  6. A Shack-Hartmann Sensor for Single-Shot Multi-Contrast Imaging with Hard X-rays

    Directory of Open Access Journals (Sweden)

    Tomy dos Santos Rolo

    2018-05-01

    Full Text Available An array of compound refractive X-ray lenses (CRL with 20 × 20 lenslets, a focal distance of 20cm and a visibility of 0.93 is presented. It can be used as a Shack-Hartmann sensor for hard X-rays (SHARX for wavefront sensing and permits for true single-shot multi-contrast imaging the dynamics of materials with a spatial resolution in the micrometer range, sensitivity on nanosized structures and temporal resolution on the microsecond scale. The object’s absorption and its induced wavefront shift can be assessed simultaneously together with information from diffraction channels. In contrast to the established Hartmann sensors the SHARX has an increased flux efficiency through focusing of the beam rather than blocking parts of it. We investigated the spatiotemporal behavior of a cavitation bubble induced by laser pulses. Furthermore, we validated the SHARX by measuring refraction angles of a single diamond CRL, where we obtained an angular resolution better than 4 μ rad.

  7. Anti-spoof touchless 3D fingerprint recognition system using single shot fringe projection and biospeckle analysis

    Science.gov (United States)

    Chatterjee, Amit; Bhatia, Vimal; Prakash, Shashi

    2017-08-01

    Fingerprint is a unique, un-alterable and easily collected biometric of a human being. Although it is a 3D biological characteristic, traditional methods are designed to provide only a 2D image. This touch based mapping of 3D shape to 2D image losses information and leads to nonlinear distortions. Moreover, as only topographic details are captured, conventional systems are potentially vulnerable to spoofing materials (e.g. artificial fingers, dead fingers, false prints, etc.). In this work, we demonstrate an anti-spoof touchless 3D fingerprint detection system using a combination of single shot fringe projection and biospeckle analysis. For fingerprint detection using fringe projection, light from a low power LED source illuminates a finger through a sinusoidal grating. The fringe pattern modulated because of features on the fingertip is captured using a CCD camera. Fourier transform method based frequency filtering is used for the reconstruction of 3D fingerprint from the captured fringe pattern. In the next step, for spoof detection using biospeckle analysis a visuo-numeric algorithm based on modified structural function and non-normalized histogram is proposed. High activity biospeckle patterns are generated because of interaction of collimated laser light with internal fluid flow of the real finger sample. This activity reduces abruptly in case of layered fake prints, and is almost absent in dead or fake fingers. Furthermore, the proposed setup is fast, low-cost, involves non-mechanical scanning and is highly stable.

  8. Single-shot measurements of low emittance beams from laser-plasma accelerators comparing two triggered injection methods

    Science.gov (United States)

    van Tilborg, Jeroen

    2017-10-01

    The success of laser plasma accelerator (LPA) based applications, such as a compact x-ray free electron laser (FEL), relies on the ability to produce electron beams with excellent 6D brightness, where brightness is defined as the ratio of charge to the product of the three normalized emittances. As such, parametric studies of the emittance of LPA generated electron beams are essential. Profiting from a stable and tunable LPA setup, combined with a carefully designed single-shot energy-dispersed emittance diagnostic, we present a direct comparison of charge dependent emittance measurements of electron beams generated by two different injection mechanisms: ionization injection and shock-induced density down-ramp injection. Both injection mechanisms have gained in popularity in recent years due to their demonstrated stable LPA performance. For the down-ramp injection configuration, normalized emittances a factor of two lower were recorded: less than 1 micron at spectral charge densities up to 2 pC/MeV. For both injection mechanisms, a contributing correlation of space charge to the emittance was identified. This measurement technique in general, and these results specifically, are critical to the evaluation of LPA injection methods and development of high-quality LPA beam lines worldwide. This work is supported by the U.S. DOE under Contract No. DE-AC02-05CH11231, by the U.S. DOE NNSA, DNN R&D (NA22), by the National Science Foundation under Grant No. PHY-1415596, and by the Gordon and Betty Moore Foundation under Grant ID GBMF4898.

  9. Non-contrast-enhanced imaging of haemodialysis fistulas using quiescent-interval single-shot (QISS) MRA: a feasibility study

    International Nuclear Information System (INIS)

    Okur, A.; Kantarci, M.; Karaca, L.; Yildiz, S.; Sade, R.; Pirimoglu, B.; Keles, M.; Avci, A.; Çankaya, E.; Schmitt, P.

    2016-01-01

    Aim: To assess the efficiency of a novel quiescent-interval single-shot (QISS) technique for non-contrast-enhanced magnetic resonance angiography (MRA) of haemodialysis fistulas. Materials and methods: QISS MRA and colour Doppler ultrasound (CDU) images were obtained from 22 haemodialysis patients with end-stage renal disease (ESRD). A radiologist with extensive experience in vascular imaging initially assessed the fistulas using CDU. Two observers analysed each QISS MRA data set in terms of image quality, using a five-point scale ranging from 0 (non-diagnostic) to 4 (excellent), and lumen diameters of all segments were measured. Results: One hundred vascular segments were analysed for QISS MRA. Two anastomosis segments were considered non-diagnostic. None of the arterial or venous segments were evaluated as non-diagnostic. The image quality was poorer for the anastomosis level compared to the other segments (p<0.001 for arterial segments, and p<0.05 for venous segments), while no significant difference was determined for other vascular segments. Conclusion: QISS MRA has the potential to provide valuable complementary information to CDU regarding the imaging of haemodialysis fistulas. In addition, QISS non-enhanced MRA represents an alternative for assessment of haemodialysis fistulas, in which the administration of iodinated or gadolinium-based contrast agents is contraindicated. - Highlights: • Close monitoring and early intervention in hemodialysis fistulas may prolong longevity fistulas. • DopplerUS, contrast enhanced CT and MRI are using assessment of hemodialysis fistulas. • QISS nonenhanced MR angiography represents an alternative for assessment of hemodialysis fistulas.

  10. Utility of single shot fast spin echo technique in evaluating pancreaticobiliary diseases: T2-weighted image and magnetic resonance cholangiopancreatography

    International Nuclear Information System (INIS)

    Choi, Byoung Wook; Kim, Myeong Jin; Chung, Jae Bok; Ko, Heung Kyu; Kim, Dong Joon; Kim, Joo Hee; Chung, Jae Joon; Yoo, Hyung Sik; Lee, Jong Tae

    1999-01-01

    To evaluate the accuracy of T2-weighted imaging an MR cholangiopancreatography using the single shot fast spin-echo technique for evaluating pancreaticobiliary disease. Between March and July 1997, axial and coronal T2-weighted images(TE: 80-200 msec) and MR cholangiopancreatograms (TE: 800-1200 msec) were obtained in two ways [single slab (thickness: 30-50 mm) and multislice acquisition under chemical fat saturation] using SSFSE pulse sequencing in 131 cases of suspected pancreati-cobiliary disease. The accuracy of SSFSE MR imaging was assessed in 89 lesions of 74 patients [male, 48; female, 26; age range, 30-86 (mean, 59) years] confirmed surgicopathologically (50 lesions in 39 patients) and clinically (39 lesions in 35 patients). Two radiologists reviewed the MR images and diagnosis was determined by consensus. Correct diagnosis was confirmed in 84 of 89 lesions (94%). Seven lesions were falsely interpreted, false positive and false negative results accounting for two and five cases, respectively. Two pancreatic cancers were misdiagnosed as pancreatitis and a cancer of the proximal common bile duct(CBD) was interpreted as a distal CBD cancer. The sensitivity of SSFSE MR imaging for malignancy was 93 %. One CBD stone revealed by endoscopic retrograde cholangiopancreatography (ERCP) was not detected on MR images. In contrast, a stone in the CBD seen on MR images was not apparent on subsequent ERCP. Sensitivity and specificity for calculous disease were 96% and 99.7%, respectively. A benign stricture of the ampulla of Vater was falsely interpreted as normal, and correct diagnosis was possible in two falsely diagnosed cases when MR images were reviewed retrospectively. The combination of T2-weighted and cholangiographic images using SSFSE is an accurate method for diagnosing pancreatcobiliary diseases

  11. Ultrafast Single-Shot Optical Oscilloscope based on Time-to-Space Conversion due to Temporal and Spatial Walk-Off Effects in Nonlinear Mixing Crystal

    Science.gov (United States)

    Takagi, Yoshihiro; Yamada, Yoshifumi; Ishikawa, Kiyoshi; Shimizu, Seiji; Sakabe, Shuji

    2005-09-01

    A simple method for single-shot sub-picosecond optical pulse diagnostics has been demonstrated by imaging the time evolution of the optical mixing onto the beam cross section of the sum-frequency wave when the interrogating pulse passes over the tested pulse in the mixing crystal as a result of the combined effect of group-velocity difference and walk-off beam propagation. A high linearity of the time-to-space projection is deduced from the process solely dependent upon the spatial uniformity of the refractive indices. A snap profile of the accidental coincidence between asynchronous pulses from separate mode-locked lasers has been detected, which demonstrates the single-shot ability.

  12. Moderately T2-weighted images obtained with the single-shot fast spin-echo technique. Differentiating between malignant and benign urinary obstructions

    International Nuclear Information System (INIS)

    Obuchi, Masao; Sugimoto, Hideharu; Kubota, Hayato; Yamamoto, Wakako; Kinebuchi, Yuko; Honda, Minoru; Takahara, Taro

    2002-01-01

    The purpose of this study was to determine whether a distinction could be made between benign and malignant urinary obstructions in moderately T 2 -weighted images obtained with the single-shot fast spin-echo technique. Forty-four lesions in 39 patients with urinary obstruction were evaluated with the single-shot fast spin-echo (SSFSE) technique with an effective TE of 90-100 ms and without fat saturation. Benign and malignant lesions were compared for the presence of ureteral wall thickening and a signal intensity relative to the proximal ureteral wall. Statistically significant differences were found between benign and malignant lesions in both morphologic change (P 2 -weighted SSFSE technique without fat saturation can accurately distinguish between benign and malignant urinary obstructions. (author)

  13. Single shot “3-in-1” femoral nerve blockade with 0.25% or 0.375% levobupivacaine provides similar postoperative analgesia for total knee replacement

    OpenAIRE

    APAN, Alpaslan; SARI, Filiz; EKMEKÇİ, Alp Burak

    2010-01-01

    To compare postoperative analgesia provided by single shot "3-in-1" femoral nerve blockade using 0.25% or 0.375% levobupivacaine in preceding with spinal anesthesia for unilateral total knee replacement surgery. Materials and methods: Forty consenting patients undergoing unilateral total knee arthroplasty were included in this prospective randomized study. Spinal anesthesia was achieved with 15 mg plain bupivacaine at the L3-4 or L4-5 interspace. After resolution of the sp...

  14. Calculation of T2 relaxation time from ultrafast single shot sequences for differentiation of liver tumors. Comparison of echo-planar, HASTE, and spin-echo sequences

    International Nuclear Information System (INIS)

    Abe, Yasuko; Yamashita, Yasuyuki; Tang, Yi; Namimoto, Tomohiro; Takahashi, Mutsumasa

    2000-01-01

    The purpose of this study was to evaluate the accuracy of T2 calculation from single shot imaging sequences such as echo-planar imaging (EPI) and half-Fourier single shot turbo spin-echo (HASTE) imaging. For the phantom study, we prepared vials containing different concentrations of agarose, copper sulfate, and nickel chloride. The temperature of the phantom was kept at 22 deg C. MR images were obtained with a 1.5-Tesla superconductive magnet. Spin-echo (SE)-type EPI and HASTE sequences with different TEs were obtained for T2 calculation, and the T2 values were compared with those obtained from the Carr-Purcell-Meiborm-Gill (CPMG) sequence. The clinical study group consisted of 30 consecutive patients referred for MR imaging to characterize focal liver lesions. A total of 40 focal liver lesions were evaluated, including 25 primary or metastatic solid masses and 15 non-solid lesions. Single shot SE-type EPI and HASTE were both performed with TEs of 64 and 90 msec. In the phantom study, the T2 values obtained from both single shot sequences showed significant correlations with those from the CPMG sequence (T2 on EPI vs. T2 on CPMG: r=0.98, p<0.01; T2 on HASTE vs. T2 on CPMG: r=0.99, p<0.01). In the clinical study, mean T2 values for liver calculated from EPI (42 msec) were significantly shorter than those calculated from the HASTE sequence (58 msec) (p<0.001). Mean T2 values for solid tumors were 95 msec with HASTE and 72 msec with EPI, and mean T2 values for non-solid lesions were 128 msec with HASTE and 159 msec with EPI. Although mean T2 values between solid and non-solid lesions were significantly different for both EPI and HASTE sequences (p=0.01 for HASTE, p<0.001 for EPI), the overlap of solid and non-solid lesions was less frequent in EPI than in HASTE. With single shot sequences, it is possible to obtain the T2 values that show excellent correlation with the CPMG sequence. Although both HASTE and EPI are useful to calculate T2 values, EPI appears to be more

  15. Will the Real Benefits of Single-Shot Interscalene Block Please Stand Up? A Systematic Review and Meta-Analysis.

    Science.gov (United States)

    Abdallah, Faraj W; Halpern, Stephen H; Aoyama, Kazuyoshi; Brull, Richard

    2015-05-01

    Interscalene block (ISB) can provide pain relief after shoulder surgery, but a reliable quantification of its analgesic benefits is lacking. This meta-analysis examines the effect of single-shot ISB on analgesic outcomes during the first 48 hours after shoulder surgery. We retrieved randomized and quasirandomized controlled trials examining the analgesic benefits of ISB compared with none in shoulder surgery. Severity of postoperative pain measured on a visual analog scale (10 cm scale, 0 = no pain, 10 = worst pain) at rest at 24 hours was the designated primary outcome. Secondary outcomes included pain severity at rest and with motion at 2, 4, 6, 8, 12, 16, 32, 36, 40, and 48 hours postoperatively. Opioid consumption, postoperative nausea and vomiting, patient satisfaction with pain relief, and postanesthesia care unit and hospital discharge time were also assessed. A total of 23 randomized controlled trials, including 1090 patients, were analyzed. Patients in the ISB group had more severe postoperative pain at rest by a weighed mean difference (95% confidence interval) of 0.96 cm (0.08-1.83; P = 0.03) at 24 hours compared with no ISB, but there was no difference in pain severity beyond that point. The duration of pain relief at rest and with motion after ISB were 8 and 6 hours, respectively, with a corresponding weighed mean difference in visual analog scale pain scores (99% confidence interval) of -1.59 cm (-2.60 to -0.58) and -2.20 cm (-4.34 to -0.06), respectively, with no additional pain relief benefits beyond these points. ISB reduced postoperative opioid consumption up to 12 hours, decreased postoperative nausea and vomiting at 24 hours, and expedited postanesthesia care unit and hospital discharge. The type, dose, and volume of local anesthetic used did not affect the results. ISB can provide effective analgesia up to 6 hours with motion and 8 hours at rest after shoulder surgery, with no demonstrable benefits thereafter. Patients who receive an ISB can

  16. Centrically reordered inversion recovery half-Fourier single-shot turbo spin-echo sequence: improvement of the image quality of oxygen-enhanced MRI

    International Nuclear Information System (INIS)

    Ohno, Yoshiharu; Hatabu, Hiroto; Higashino, Takanori; Kawamitsu, Hideaki; Watanabe, Hirokazu; Takenaka, Daisuke; Cauteren, Marc van; Sugimura, Kazuro

    2004-01-01

    Purpose: The purpose of the study presented here was to determine the improvement in image quality of oxygen-enhanced magnetic resonance (MR) subtraction imaging obtained with a centrically reordered inversion recovery half-Fourier single-shot turbo spin-echo (c-IR-HASTE) sequence compared with that obtained with a conventional sequentially reordered inversion recovery single-shot HASTE (s-IR-HASTE) sequence for pulmonary imaging. Materials and methods: Oxygen-enhanced MR imaging using a 1.5 T whole body scanner was performed on 12 healthy, non-smoking volunteers. Oxygen-enhanced MR images were obtained with the coronal two-dimensional (2D) c-IR-HASTE sequence and 2D s-IR-HASTE sequence combined with respiratory triggering. For a 256x256 matrix, 132 phase-encoding steps were acquired including four steps for phase correction. Inter-echo spacing for each sequence was 4.0 ms. The effective echo time (TE) for c-IR-HASTE was 4.0 ms, and 16 ms for s-IR-HASTE. The inversion time (TI) was 900 ms. To determine the improvement in oxygen-enhanced MR subtraction imaging by c-IR-HASTE, CNRs of subtraction image, overall image quality, and image degradation of the c-IR-HASTE and s-IR-HASTE techniques were statistically compared. Results: CNR, overall image quality, and image degradation of c-IR-HASTE images showed significant improvement compared to those s-IR-HASTE images (P<0.05). Conclusion: Centrically reordered inversion recovery half-Fourier single-shot turbo spin-echo (c-IR-HASTE) sequence enhanced the signal from the lung and improved the image quality of oxygen-enhanced MR subtraction imaging

  17. LiNbO/sub 3/:Ti directional-coupler modulators for high-bandwidth, single-shot instrumentation systems operating at 800 nm

    International Nuclear Information System (INIS)

    Lowry, M.; Jander, D.; Lancaster, G.; Kwiat, P.; McWright, G.; Peterson, R.T.; Tindall, W.; Roeske, F.

    1987-01-01

    The authors update their work on optical directional-coupler modulators (ODCMs) for single-shot, analog instrumentation systems operating at -- 800 nm. They can now fabricate directional-coupler devices that have one input and two output pigtails with insertion losses of 8.9 dB on average. Data for the ODCMs indicate an impulse response of less than 40 ps. They have implemented these devices in an ultrafast, x-ray measurement system. They discuss our data from this implementation and their implications for continued ODCM development

  18. Lowering of L10 phase transition temperature of FePt thin films by single shot H+ ion exposure using plasma focus device

    International Nuclear Information System (INIS)

    Pan, Z.Y.; Lin, J.J.; Zhang, T.; Karamat, S.; Tan, T.L.; Lee, P.; Springham, S.V.; Ramanujan, R.V.; Rawat, R.S.

    2009-01-01

    FePt thin films are exposed to pulsed energetic H + ion beam from plasma focus. In irradiated films, the phase transition from the low K u disordered face-centered-cubic structure to high K u ordered face-centered-tetragonal phase was achieved at 400 deg. C with the order parameter S ranging from 0.73 to 0.83, high coercivity of about 5356 kA/m, high negative nucleation field of about 7700 kA/m and high squareness ratio ranging from 0.73 to 0.79. The advantage of using plasma focus device is that it can lower phase transition temperature and significantly enhance the magnetic properties by a pulsed single shot exposure

  19. Anterior chamber configuration in patients with glaucoma: MR gonioscopy evaluation with half-Fourier single-shot RARE sequence and microscopy coil.

    Science.gov (United States)

    Tanitame, Keizo; Sasaki, Ko; Sone, Takashi; Uyama, Shinji; Sumida, Masumi; Ichiki, Toshio; Ito, Katsuhide

    2008-10-01

    The purpose of the study was to determine the accuracy of half-Fourier single-shot rapid acquisition with relaxation enhancement high-spatial-resolution magnetic resonance (MR) imaging performed with a microscopy coil in the diagnosis of narrow anterior chamber angle in patients with glaucoma. Slit-lamp biomicroscopy served as the reference standard. The institutional review board approved this study, and written informed consent was obtained from the 20 recruited patients. There was excellent agreement between MR gonioscopy and slit-lamp biomicroscopy in the classification of anterior chamber angles as narrow or open (kappa = 0.89 [95% confidence interval: 0.69, 1.10]). MR gonioscopy has substantial potential as a technique used to evaluate glaucoma. (c) RSNA, 2008.

  20. Single-shot full strain tensor determination with microbeam X-ray Laue diffraction and a two-dimensional energy-dispersive detector.

    Science.gov (United States)

    Abboud, A; Kirchlechner, C; Keckes, J; Conka Nurdan, T; Send, S; Micha, J S; Ulrich, O; Hartmann, R; Strüder, L; Pietsch, U

    2017-06-01

    The full strain and stress tensor determination in a triaxially stressed single crystal using X-ray diffraction requires a series of lattice spacing measurements at different crystal orientations. This can be achieved using a tunable X-ray source. This article reports on a novel experimental procedure for single-shot full strain tensor determination using polychromatic synchrotron radiation with an energy range from 5 to 23 keV. Microbeam X-ray Laue diffraction patterns were collected from a copper micro-bending beam along the central axis (centroid of the cross section). Taking advantage of a two-dimensional energy-dispersive X-ray detector (pnCCD), the position and energy of the collected Laue spots were measured for multiple positions on the sample, allowing the measurement of variations in the local microstructure. At the same time, both the deviatoric and hydrostatic components of the elastic strain and stress tensors were calculated.

  1. Distortion-free diffusion tensor imaging for evaluation of lumbar nerve roots: Utility of direct coronal single-shot turbo spin-echo diffusion sequence.

    Science.gov (United States)

    Sakai, Takayuki; Doi, Kunio; Yoneyama, Masami; Watanabe, Atsuya; Miyati, Tosiaki; Yanagawa, Noriyuki

    2018-06-01

    Diffusion tensor imaging (DTI) based on a single-shot echo planer imaging (EPI-DTI) is an established method that has been used for evaluation of lumbar nerve disorders in previous studies, but EPI-DTI has problems such as a long acquisition time, due to a lot of axial slices, and geometric distortion. To solve these problems, we attempted to apply DTI based on a single-shot turbo spin echo (TSE-DTI) with direct coronal acquisition. Our purpose in this study was to investigate whether TSE-DTI may be more useful for evaluation of lumbar nerve disorders than EPI-DTI. First, lumbar nerve roots of five healthy volunteers were evaluated for optimization of imaging parameters with TSE-DTI including b-values and the number of motion proving gradient (MPG) directions. Subsequently, optimized TSE-DTI was quantitatively compared with conventional EPI-DTI by using fractional anisotropy (FA) values and visual scores in subjective visual evaluation of tractography. Lumbar nerve roots of six patients, who had unilateral neurologic symptoms in one leg, were evaluated by the optimized TSE-DTI. TSE-DTI with b-value of 400 s/mm 2 and 32 diffusion-directions could reduce the image distortion compared with EPI-DTI, and showed that the average FA values on the symptomatic side for six patients were significantly lower than those on the non-symptomatic side (P DTI might show damaged areas of lumbar nerve roots without severe image distortion. TSE-DTI might improve the reproducibility in measurements of FA values for quantification of a nerve disorder, and would become a useful tool for diagnosis of low back pain. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. Event-related oscillations (EROs) and event-related potentials (ERPs) comparison in facial expression recognition.

    Science.gov (United States)

    Balconi, Michela; Pozzoli, Uberto

    2007-09-01

    The study aims to explore the significance of event-related potentials (ERPs) and event-related brain oscillations (EROs) (delta, theta, alpha, beta, gamma power) in response to emotional (fear, happiness, sadness) when compared with neutral faces during 180-250 post-stimulus time interval. The ERP results demonstrated that the emotional face elicited a negative peak at approximately 230 ms (N2). Moreover, EEG measures showed that motivational significance of face (emotional vs. neutral) could modulate the amplitude of EROs, but only for some frequency bands (i.e. theta and gamma bands). In a second phase, we considered the resemblance of the two EEG measures by a regression analysis. It revealed that theta and gamma oscillations mainly effect as oscillation activity at the N2 latency. Finally, a posterior increased power of theta was found for emotional faces.

  3. Optimization of mass spectrometric parameters improve the identification performance of capillary zone electrophoresis for single-shot bottom-up proteomics analysis.

    Science.gov (United States)

    Zhang, Zhenbin; Dovichi, Norman J

    2018-02-25

    The effects of MS1 injection time, MS2 injection time, dynamic exclusion time, intensity threshold, and isolation width were investigated on the numbers of peptide and protein identifications for single-shot bottom-up proteomics analysis using CZE-MS/MS analysis of a Xenopus laevis tryptic digest. An electrokinetically pumped nanospray interface was used to couple a linear-polyacrylamide coated capillary to a Q Exactive HF mass spectrometer. A sensitive method that used a 1.4 Th isolation width, 60,000 MS2 resolution, 110 ms MS2 injection time, and a top 7 fragmentation produced the largest number of identifications when the CZE loading amount was less than 100 ng. A programmable autogain control method (pAGC) that used a 1.4 Th isolation width, 15,000 MS2 resolution, 110 ms MS2 injection time, and top 10 fragmentation produced the largest number of identifications for CZE loading amounts greater than 100 ng; 7218 unique peptides and 1653 protein groups were identified from 200 ng by using the pAGC method. The effect of mass spectrometer conditions on the performance of UPLC-MS/MS was also investigated. A fast method that used a 1.4 Th isolation width, 30,000 MS2 resolution, 45 ms MS2 injection time, and top 12 fragmentation produced the largest number of identifications for 200 ng UPLC loading amount (6025 unique peptides and 1501 protein groups). This is the first report where the identification number for CZE surpasses that of the UPLC at the 200 ng loading level. However, more peptides (11476) and protein groups (2378) were identified by using UPLC-MS/MS when the sample loading amount was increased to 2 μg with the fast method. To exploit the fast scan speed of the Q-Exactive HF mass spectrometer, higher sample loading amounts are required for single-shot bottom-up proteomics analysis using CZE-MS/MS. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Nonenhanced ECG-gated quiescent-interval single-shot MRA (QISS-MRA) of the lower extremities: Comparison with contrast-enhanced MRA

    Energy Technology Data Exchange (ETDEWEB)

    Klasen, J. [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Blondin, D., E-mail: blondin@med.uni-duesseldorf.de [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Schmitt, P. [Siemens AG, Healthcare Sector, Erlangen (Germany); Bi, X. [Siemens Healthcare, Chicago, IL (United States); Sansone, R. [Department of Cardiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Wittsack, H.-J.; Kroepil, P.; Quentin, M.; Kuhlemann, J.; Miese, F. [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Heiss, C.; Kelm, M. [Department of Cardiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Antoch, G.; Lanzman, R.S. [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany)

    2012-05-15

    Aim: To evaluate electrocardiogram (ECG)-gated quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) for nonenhanced assessment of peripheral artery occlusive disease (PAOD) using contrast-enhanced MRA (CE-MRA) as the reference standard. Materials and methods: Twenty-seven patients (mean age 66.6 {+-} 10.8 years) with PAOD were included in the study. QISS-MRA and CE-MRA of the lower extremity were performed using a 1.5 T MR scanner. In each patient, subjective image quality and the degree of stenosis were evaluated on a four-point scale for 15 predefined arterial segments. Results: Twenty-five of the 27 patients were considered for analysis. Subjective image quality of QISS-MRA was significantly lower for the distal aorta, pelvic arteries, and femoral arteries as compared to CE-MRA (p < 0.01), while no significant difference was found for other vascular segments. The degree of stenosis was overestimated with QISS-MRA in 23 of 365 (6.3%) segments and underestimated in two of 365 (0.5%) segments. As compared to CE-MRA, QISS-MRA had a high sensitivity (98.6%), specificity (96%) as well as positive and negative predictive value (88.7 and 99.6%, respectively) for the detection of significant stenosis ({>=}50%). Conclusion: ECG-gated QISS-MRA is a promising imaging technique for reliable assessment of PAOD without the use of contrast material.

  5. Differential diagnosis of pituitary adenomas and Rathke's cleft cysts by diffusion-weighted MRI using single-shot fast spin echo technique

    International Nuclear Information System (INIS)

    Abe, Takumi; Izumiyama, Hitoshi; Fukuda, Ataru; Tanioka, Daisuke; Kunii, Norihiko; Komatsu, Daisuke; Fujita, Shogo; Ukisu, Ryutaro; Moritani, Toshio

    2002-01-01

    The purpose of the present study was to prospectively evaluate the diagnostic ability of diffusion-weighted magnetic resonance imaging (DWI) using single-shot fast spin echo (SSFSE) technique to discriminate pituitary adenomas from Rathke's cleft cysts. DWIs were obtained from 40 patients with pathologically proven pituitary macroadenomas and 15 patients with proven Rathke's cleft cysts. Pituitary adenomas were divided into 27 cases with solid components alone, five with non-hemorrhagic large cysts, and eight with intratumoral hemorrhage. On SSFSE DWI, solid components of pituitary adenomas revealed iso or slightly increased intensity and intratumoral hemorrhage showed higher intensity than normal brain parenchyma, whereas Rathke's cleft cysts and intratumoral cysts demonstrated very low intensity. SSFSE DWI did not display the susceptibility artifacts that are seen close to the skull base and sinonasal cavities on echo planar diffusion imaging. On the basis of our preliminary findings, DWI may enable us to differentiate pituitary adenomas with only solid components and hemorrhagic pituitary adenomas appearing hyperintense on T1-weighted images from Rathke's cleft cysts without administration of gadolinium-DTPA. SSFSE DWI appears to be a useful technique for characterizing pituitary diseases without the susceptibility artifacts. Our study is the first report to demonstrate the identification of pituitary disorders on SSFSE DWI. (author)

  6. Differential diagnosis of pituitary adenomas and Rathke's cleft cysts by diffusion-weighted MRI using single-shot fast spin echo technique

    Energy Technology Data Exchange (ETDEWEB)

    Abe, Takumi; Izumiyama, Hitoshi; Fukuda, Ataru; Tanioka, Daisuke; Kunii, Norihiko; Komatsu, Daisuke; Fujita, Shogo; Ukisu, Ryutaro; Moritani, Toshio [Showa Univ., Tokyo (Japan). School of Medicine

    2002-09-01

    The purpose of the present study was to prospectively evaluate the diagnostic ability of diffusion-weighted magnetic resonance imaging (DWI) using single-shot fast spin echo (SSFSE) technique to discriminate pituitary adenomas from Rathke's cleft cysts. DWIs were obtained from 40 patients with pathologically proven pituitary macroadenomas and 15 patients with proven Rathke's cleft cysts. Pituitary adenomas were divided into 27 cases with solid components alone, five with non-hemorrhagic large cysts, and eight with intratumoral hemorrhage. On SSFSE DWI, solid components of pituitary adenomas revealed iso or slightly increased intensity and intratumoral hemorrhage showed higher intensity than normal brain parenchyma, whereas Rathke's cleft cysts and intratumoral cysts demonstrated very low intensity. SSFSE DWI did not display the susceptibility artifacts that are seen close to the skull base and sinonasal cavities on echo planar diffusion imaging. On the basis of our preliminary findings, DWI may enable us to differentiate pituitary adenomas with only solid components and hemorrhagic pituitary adenomas appearing hyperintense on T1-weighted images from Rathke's cleft cysts without administration of gadolinium-DTPA. SSFSE DWI appears to be a useful technique for characterizing pituitary diseases without the susceptibility artifacts. Our study is the first report to demonstrate the identification of pituitary disorders on SSFSE DWI. (author)

  7. Readout-Segmented Echo-Planar Imaging in Diffusion-Weighted MR Imaging in Breast Cancer: Comparison with Single-Shot Echo-Planar Imaging in Image Quality

    International Nuclear Information System (INIS)

    Kim, Yun Ju; Kim, Sung Hun; Kang, Bong Joo; Park, Chang Suk; Kim, Hyeon Sook; Son, Yo Han; Porter, David Andrew; Song, Byung Joo

    2014-01-01

    The purpose of this study was to compare the image quality of standard single-shot echo-planar imaging (ss-EPI) and that of readout-segmented EPI (rs-EPI) in patients with breast cancer. Seventy-one patients with 74 breast cancers underwent both ss-EPI and rs-EPI. For qualitative comparison of image quality, three readers independently assessed the two sets of diffusion-weighted (DW) images. To evaluate geometric distortion, a comparison was made between lesion lengths derived from contrast enhanced MR (CE-MR) images and those obtained from the corresponding DW images. For assessment of image parameters, signal-to-noise ratio (SNR), lesion contrast, and contrast-to-noise ratio (CNR) were calculated. The rs-EPI was superior to ss-EPI in most criteria regarding the qualitative image quality. Anatomical structure distinction, delineation of the lesion, ghosting artifact, and overall image quality were significantly better in rs-EPI. Regarding the geometric distortion, lesion length on ss-EPI was significantly different from that of CE-MR, whereas there were no significant differences between CE-MR and rs-EPI. The rs-EPI was superior to ss-EPI in SNR and CNR. Readout-segmented EPI is superior to ss-EPI in the aspect of image quality in DW MR imaging of the breast

  8. Nonenhanced ECG-gated quiescent-interval single-shot MRA (QISS-MRA) of the lower extremities: Comparison with contrast-enhanced MRA

    International Nuclear Information System (INIS)

    Klasen, J.; Blondin, D.; Schmitt, P.; Bi, X.; Sansone, R.; Wittsack, H.-J.; Kröpil, P.; Quentin, M.; Kuhlemann, J.; Miese, F.; Heiss, C.; Kelm, M.; Antoch, G.; Lanzman, R.S.

    2012-01-01

    Aim: To evaluate electrocardiogram (ECG)-gated quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) for nonenhanced assessment of peripheral artery occlusive disease (PAOD) using contrast-enhanced MRA (CE-MRA) as the reference standard. Materials and methods: Twenty-seven patients (mean age 66.6 ± 10.8 years) with PAOD were included in the study. QISS-MRA and CE-MRA of the lower extremity were performed using a 1.5 T MR scanner. In each patient, subjective image quality and the degree of stenosis were evaluated on a four-point scale for 15 predefined arterial segments. Results: Twenty-five of the 27 patients were considered for analysis. Subjective image quality of QISS-MRA was significantly lower for the distal aorta, pelvic arteries, and femoral arteries as compared to CE-MRA (p < 0.01), while no significant difference was found for other vascular segments. The degree of stenosis was overestimated with QISS-MRA in 23 of 365 (6.3%) segments and underestimated in two of 365 (0.5%) segments. As compared to CE-MRA, QISS-MRA had a high sensitivity (98.6%), specificity (96%) as well as positive and negative predictive value (88.7 and 99.6%, respectively) for the detection of significant stenosis (≥50%). Conclusion: ECG-gated QISS-MRA is a promising imaging technique for reliable assessment of PAOD without the use of contrast material.

  9. Development of Compton X-ray spectrometer for high energy resolution single-shot high-flux hard X-ray spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kojima, Sadaoki, E-mail: kojima-s@ile.osaka-u.ac.jp, E-mail: sfujioka@ile.osaka-u.ac.jp; Ikenouchi, Takahito; Arikawa, Yasunobu; Sakata, Shohei; Zhang, Zhe; Abe, Yuki; Nakai, Mitsuo; Nishimura, Hiroaki; Shiraga, Hiroyuki; Fujioka, Shinsuke, E-mail: kojima-s@ile.osaka-u.ac.jp, E-mail: sfujioka@ile.osaka-u.ac.jp; Azechi, Hiroshi [Institute of Laser Engineering, Osaka University, 2-6 Yamada-oka, Suita, Osaka 565-0871 (Japan); Ozaki, Tetsuo [National Institute for Fusion Science, 322-6 Oroshi, Toki, Gifu 509-5292 (Japan); Miyamoto, Shuji; Yamaguchi, Masashi; Takemoto, Akinori [Laboratory of Advanced Science and Technology for Industry, University of Hyogo, 3-1-2 Kouto, Kamigori-cho, Ako-gun, Hyogo 678-1205 (Japan)

    2016-04-15

    Hard X-ray spectroscopy is an essential diagnostics used to understand physical processes that take place in high energy density plasmas produced by intense laser-plasma interactions. A bundle of hard X-ray detectors, of which the responses have different energy thresholds, is used as a conventional single-shot spectrometer for high-flux (>10{sup 13} photons/shot) hard X-rays. However, high energy resolution (Δhv/hv < 0.1) is not achievable with a differential energy threshold (DET) X-ray spectrometer because its energy resolution is limited by energy differences between the response thresholds. Experimental demonstration of a Compton X-ray spectrometer has already been performed for obtaining higher energy resolution than that of DET spectrometers. In this paper, we describe design details of the Compton X-ray spectrometer, especially dependence of energy resolution and absolute response on photon-electron converter design and its background reduction scheme, and also its application to the laser-plasma interaction experiment. The developed spectrometer was used for spectroscopy of bremsstrahlung X-rays generated by intense laser-plasma interactions using a 200 μm thickness SiO{sub 2} converter. The X-ray spectrum obtained with the Compton X-ray spectrometer is consistent with that obtained with a DET X-ray spectrometer, furthermore higher certainly of a spectral intensity is obtained with the Compton X-ray spectrometer than that with the DET X-ray spectrometer in the photon energy range above 5 MeV.

  10. Faster pediatric 3-T abdominal magnetic resonance imaging: comparison between conventional and variable refocusing flip-angle single-shot fast spin-echo sequences

    Energy Technology Data Exchange (ETDEWEB)

    Ruangwattanapaisarn, Nichanan [Mahidol University, Department of Diagnostic and Therapeutic Radiology, Ramathibodi Hospital, Bangkok (Thailand); Stanford University, LPCH Department of Radiology, Stanford, CA (United States); Loening, Andreas M.; Saranathan, Manojkumar; Vasanawala, Shreyas S. [Stanford University, LPCH Department of Radiology, Stanford, CA (United States); Litwiller, Daniel V. [GE Healthcare, Rochester, MN (United States)

    2015-06-15

    Single-shot fast spin echo (SSFSE) is particularly appealing in pediatric patients because of its motion robustness. However radiofrequency energy deposition at 3 tesla forces long pauses between slices, leading to longer scans, longer breath-holds and more between-slice motion. We sought to learn whether modulation of the SSFSE refocusing flip-angle train could reduce radiofrequency energy deposition without degrading image quality, thereby reducing inter-slice pauses and overall scan times. We modulated the refocusing flip-angle train for SSFSE to minimize energy deposition while minimizing blurring and motion-related signal loss. In a cohort of 50 consecutive patients (25 boys, mean age 5.5 years, range 1 month to 17 years) referred for abdominal MRI we obtained standard SSFSE and variable refocusing flip-angle (vrfSSFSE) images and recorded sequence scan times. Two readers independently scored the images in blinded, randomized order for noise, tissue contrast, sharpness, artifacts and left lobe hepatic signal uniformity on a four-point scale. The null hypothesis of no difference between SSFSE and vrfSSFSE image-quality was assessed with a Mann-Whitney U test, and the null hypothesis of no scan time difference was assessed with the paired t-test. SSFSE and vrfSSFSE mean acquisition times were 54.3 and 26.2 s, respectively (P-value <0.0001). For each reader, SSFSE and vrfSSFSE noise, tissue contrast, sharpness and artifacts were not significantly different (P-values 0.18-0.86). However, SSFSE had better left lobe hepatic signal uniformity (P < 0.01, both readers). vrfSSFSE is twice as fast as SSFSE, with equivalent image quality with the exception of left hepatic lobe signal heterogeneity. (orig.)

  11. Highly Resolved Mg/Ca Depth Profiles of Planktic Foraminifer test Walls Using Single shot Measurements of fs-LA-ICPMS

    Science.gov (United States)

    Jochum, K. P.; Schiebel, R.; Stoll, B.; Weis, U.; Haug, G. H.

    2017-12-01

    Foraminifers are sensitive archives of changes in climate and marine environment. It has been shown that the Mg/Ca signal is a suitable proxy of seawater temperature, because the incorporation of Mg depends on ambient water temperature. In contrast to most former studies, where this ratio is determined by solution-based bulk analysis of 20 - 30 specimens, we have investigated Mg/Ca in single specimens and single chambers at high resolution. A new fs-200 nm-LA-ICPMS technique was developed for the µm-sized layered calcite shells. To generate depth profiles with a resolution of about 50 nm/shot, we chose a low fluence of about 0.3 Jcm-2 and performed single shot measurements of the double charged 44Ca++ and the single charged 25Mg+ ions together. Precision (RSD) of the Mg/Ca data is about 5 %. Calibration was performed with the carbonate reference material MACS-3 from the USGS. Our results for different species from the Arabian Sea and Caribbean Sea demonstrate that Mg/Ca of different chambers vary and indicate that the foraminifer individuals built their chambers in different water depths and/or experienced seasonal changes in seawater temperature caused, for example, by upwelling (cold) versus stratified (warm) conditions. Typically, the Mg/Ca ratios of the final two chambers of the planktic foraminifer Globorotalia menardii from a sediment core of the Arabian Sea differ by about 5 mmol/mol from earlier chambers (2 mmol/mol) corresponding to seawater temperatures of 28 °C and 18 °C, respectively. In addition, mass fractions of other elements like Sr, Mn, Fe, Ba, and U have been determined with fs-LA-ICPMS using fast line scans, and thus provide further insights in the ecology of foraminifers.

  12. Non-contrast-enhanced MR angiography in critical limb ischemia: performance of quiescent-interval single-shot (QISS) and TSE-based subtraction techniques

    Energy Technology Data Exchange (ETDEWEB)

    Altaha, Mustafa A. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); Jaskolka, Jeffrey D.; Tan, Kongteng; Menezes, Ravi J. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); University of Toronto, Department of Medical Imaging, Toronto, Ontario (Canada); Rick, Manuela; Schmitt, Peter [Siemens Healthcare, Erlangen (Germany); Wintersperger, Bernd J. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); University of Toronto, Department of Medical Imaging, Toronto, Ontario (Canada); Toronto General Hospital, Department of Medical Imaging, Toronto, Ontario (Canada)

    2017-03-15

    The aim of this study was to evaluate diagnostic performance of non-contrast-enhanced 2D quiescent-interval single-shot (QISS) and 3D turbo spin-echo (TSE)-based subtraction magnetic resonance angiography (MRA) in the assessment of peripheral arteries in patients with critical limb ischemia (CLI). Nineteen consecutive patients (74 % male, 72.8 ± 9.9 years) with CLI underwent 2D QISS and 3D TSE-based subtraction MRA at 1.5 T. Axial-overlapping QISS MRA (3 mm/2 mm; 1 x 1 mm{sup 2}) covered from the toes to the aortic bifurcation while coronal 3D TSE-based subtraction MRA (1.3 x 1.2 x 1.3 mm{sup 3}) was restricted to the calf only. MRA data sets (two readers) were evaluated for stenosis (≥50 %) and image quality. Results were compared with digital subtraction angiography (DSA). Two hundred and sixty-seven (267) segments were available for MRA-DSA comparison, with a prevalence of stenosis ≥50 % of 41.9 %. QISS MRA was rated as good to excellent in 79.5-96.0 % of segments without any nondiagnostic segments; 89.8-96.1 % of segments in 3D TSE-based subtraction MRA were rated as nondiagnostic or poor. QISS MRA sensitivities and specificities (segmental) were 92 % and 95 %, respectively, for reader one and 81-97 % for reader two. Due to poor image quality of 3D TSE-based subtraction MRA, diagnostic performance measures were not calculated. QISS MRA demonstrates excellent diagnostic performance and higher robustness than 3D TSE-based subtraction MRA in the challenging patient population with CLI. (orig.)

  13. Comparison of respiratory-triggered 3-D fast spin-echo and single-shot fast spin-echo radial slab MR cholangiopancreatography images in children

    Energy Technology Data Exchange (ETDEWEB)

    Chavhan, Govind B.; Almehdar, Abeer; Gupta, Sumeet [The Hospital for Sick Children and University of Toronto, Department of Diagnostic Imaging, Toronto (Canada); Moineddin, Rahim [University of Toronto, Department of Family and Community Medicine, Toronto (Canada); Babyn, Paul S. [Royal University Hospital, Department of Medical Imaging, Saskatoon (Canada)

    2013-09-15

    The two most commonly performed magnetic resonance cholangiopancreatography (MRCP) sequences, 3-D fast spin-echo (3-D FSE) and single-shot fast spin-echo radial slabs (radial slabs), have not been compared in children. The purpose of this study was to compare 3-D FSE and radial slabs MRCP sequences on a 3-T scanner to determine their ability to show various segments of pancreaticobiliary tree and presence of artifacts in children. We reviewed 79 consecutive MRCPs performed in 74 children on a 3-T scanner. We noted visibility of major ducts on 3-D FSE and radial slabs. We noted the order of branching of ducts in the right and left hepatic ducts and the degree of visibility of the pancreatic duct. Statistical analysis was performed using McNemar and signed rank tests. There was no significant difference in the visibility of major bile ducts and the order of branching in the right hepatic lobe between sequences. A higher order of branching in the left lobe was seen on radial slabs than 3-D FSE (mean order of branching 2.82 versus 2.27; P-value = 0.0002). The visibility of pancreatic duct was better on radial slabs as compared to 3-D FSE (mean value of 1.53 vs. 0.90; P-value < 0.0001). 3-D FSE sequence was artifact-free in 25/79 (31.6%) MRCP exams as compared to radial slabs, which were artifact-free in 18/79 (22.8%) MRCP exams (P-value = 0.0001). There is no significant difference in the visibility of major bile ducts between 3-D FSE and radial slab MRCP sequences at 3-T in children. However, radial slab MRCP shows a higher order of branching in the left hepatic lobe and superior visibility of the pancreatic duct than 3-D FSE. (orig.)

  14. Diffusion tensor trace mapping in normal adult brain using single-shot EPI technique: A methodological study of the aging brain

    International Nuclear Information System (INIS)

    Chen, Z.G.; Hindmarsh, T.; Li, T.Q.

    2001-01-01

    Purpose: To quantify age-related changes of the average diffusion coefficient value in normal adult brain using orientation-independent diffusion tensor trace mapping and to address the methodological influences on diffusion quantification. Material and Methods: Fifty-four normal subjects (aged 20-79 years) were studied on a 1.5-T whole-body MR medical unit using a diffusion-weighted single-shot echo-planar imaging technique. Orientation-independent diffusion tensor trace maps were constructed for each subject using diffusion-weighted MR measurements in four different directions using a tetrahedral gradient combination pattern. The global average (including cerebral spinal fluid) and the tissue average of diffusion coefficients in adult brains were determined by analyzing the diffusion coefficient distribution histogram for the entire brain. Methodological influences on the measured diffusion coefficient were also investigated by comparing the results obtained using different experimental settings. Results: Both global and tissue averages of the diffusion coefficient are significantly correlated with age (p<0.03). The global average of the diffusion coefficient increases 3% per decade after the age of 40, whereas the increase in the tissue average of diffusion coefficient is about 1% per decade. Experimental settings for self-diffusion measurements, such as data acquisition methods and number of b-values, can slightly influence the statistical distribution histogram of the diffusion tensor trace and its average value. Conclusion: Increased average diffusion coefficient in adult brains with aging are consistent with findings regarding structural changes in the brain that have been associated with aging. The study also demonstrates that it is desirable to use the same experimental parameters for diffusion coefficient quantification when comparing between different subjects and groups of interest

  15. The role of MR imaging with Half Fourier Acquired Single Shot Turbo Spin Echo sequence in the diagnosis of lung lesions in comparison with multislice CT

    International Nuclear Information System (INIS)

    Hekimoglu, B.; Gurgen, F.; Tatar, I.G.; Aydin, H.; Kizilgoz, V.; Keyik, B.

    2013-01-01

    Objective: To compare the diagnostic values of magnetic resonance imaging using Half Fourier Acquired Single Shot Turbo Spin Echo sequence and multidetector computed tomography in patients with pathologically examined pulmonary lesions. Methods: The retrospective, descriptive study was conducted at Radiology Department, Diskapi Research Hospital, Ankara, Turkey, and comprised records of patients with pathologically examined pulmonary lesions between May 2009 and March 2012. Patients were divided into three groups and examined by both multi dedector computed tomography and magnetic resonance imaging. During the imaging, patients were not administered any intravenous contrast medium. Electrocardiogram gating and breath holding were not performed in echo sequence. Pulmonary lesions were evaluated on the basis of their dimensions, numbers, differentiation from atelectasis and consolidation, invasion to the thoracic wall-mediastinal structures and presence of lymphadenopathies. Results: Sensitivity of all patients was 50% (p=0.214) and specificity of CT and MRI were 82.5% (p=0.134) for the detectability of submilimetric nodules . For differentiation of the mass from atelectasis and consolidation, the sensitivity of computed tomography was statistically more significant compared to magnetic resonance imaging (86.6%; p=0.035). For the invasion of the mass to the mediastinal structures and the thoracic wall, the sensitivity of magnetic resonance imaging was statistically more significant compared to tomography (86.6%; p=0.035). Conclusion: HASTE sequence can be used to determine the invasion of the pulmonary mass to the mediastinal structures and the thoracic wall since it is more sensitive than computed tomography. It can also be used to detect submilimetric nodules. It has equal sensitivity and specificity compared to computed tomography. But computed tomography is superior for the differentiation of the mass from atelectasis and consolidation. (author)

  16. Non-contrast-enhanced MR angiography in critical limb ischemia: performance of quiescent-interval single-shot (QISS) and TSE-based subtraction techniques

    International Nuclear Information System (INIS)

    Altaha, Mustafa A.; Jaskolka, Jeffrey D.; Tan, Kongteng; Menezes, Ravi J.; Rick, Manuela; Schmitt, Peter; Wintersperger, Bernd J.

    2017-01-01

    The aim of this study was to evaluate diagnostic performance of non-contrast-enhanced 2D quiescent-interval single-shot (QISS) and 3D turbo spin-echo (TSE)-based subtraction magnetic resonance angiography (MRA) in the assessment of peripheral arteries in patients with critical limb ischemia (CLI). Nineteen consecutive patients (74 % male, 72.8 ± 9.9 years) with CLI underwent 2D QISS and 3D TSE-based subtraction MRA at 1.5 T. Axial-overlapping QISS MRA (3 mm/2 mm; 1 x 1 mm 2 ) covered from the toes to the aortic bifurcation while coronal 3D TSE-based subtraction MRA (1.3 x 1.2 x 1.3 mm 3 ) was restricted to the calf only. MRA data sets (two readers) were evaluated for stenosis (≥50 %) and image quality. Results were compared with digital subtraction angiography (DSA). Two hundred and sixty-seven (267) segments were available for MRA-DSA comparison, with a prevalence of stenosis ≥50 % of 41.9 %. QISS MRA was rated as good to excellent in 79.5-96.0 % of segments without any nondiagnostic segments; 89.8-96.1 % of segments in 3D TSE-based subtraction MRA were rated as nondiagnostic or poor. QISS MRA sensitivities and specificities (segmental) were 92 % and 95 %, respectively, for reader one and 81-97 % for reader two. Due to poor image quality of 3D TSE-based subtraction MRA, diagnostic performance measures were not calculated. QISS MRA demonstrates excellent diagnostic performance and higher robustness than 3D TSE-based subtraction MRA in the challenging patient population with CLI. (orig.)

  17. Comparison of single-shot fast spin-echo sequence and T2-weighted fast spin-echo sequence in MR imaging of the brain

    International Nuclear Information System (INIS)

    Cha, Sung Ho; Seo, Jeong Jin; Jeong, Gwang Woo; Kim, Jae Kyu; Kim, Yun Hyeon; Jeong, Yong Yeon; Kang, Heoung Keun; Oh, Hee Yeon; Yoon, Jong Hoon

    1998-01-01

    The purpose of this study was to evaluate the usefulness of the single-shot fast spinecho (SS-FSE) sequence in comparison with the T2-weighted fast spin-echo (T2-FSE) sequence in brain MR imaging. In 41 patients aged 15-75 years with intracranial lesion, both SS-FSE and T2-FES images were obtained using a 1.5-T MR system. Lesions included cerebral ischemia or infarcts (n=3D23), tumors (n=3D10), hemorrhages (n=3D3), inflammatory diseases (n=3D2), arachnoid cysts(n=3D2), and vascular disease (n=3D1), and the MR images were retrospectively evaluated. To calculate contrast-to-noise ratio (CNR), percentage contrast, and signal-to-noise ratio (SNR)-and thus make a quantitative comparison-the mean signal intensities of lesions, normal brain tissue, and noise out-side the patient were measured. For qualitative comparison, the visibility, margin, and extent of the lesions were rated using a five-grade system, and the degree of MR artifacts was also evaluated. Wilcoxon's signed ranks test was used for statistical analysis. The mean CNR of lesions was significantly higher on SS-FSE (31.3) than on T2-FSE images (27.5) (p=3D0.0131). Mean percentage contrast was also higher on SS-FSE (159.0) than on T2-FSE images (108.5) (p=3D0.0222), but mean SNR was higher on T2-FSE (80.3) than on SS-FSE images (53.5) (p=3D0.0000). No significant differences in lesion visibility were observed between the two imaging sequences, though margin and extent of the lesion were worse on SS-FSE images. For MR artifacts, no significant differences were demonstrated. For the evaluation of most intracranial lesions, MR imaging using the SS-FSE sequence appears to be slightly inferior to the T2-FSE sequence, but may be useful where patients are ill or uncooperative, or where children require sedation.=20

  18. ECG-gated quiescent-interval single-shot MR angiography of the lower extremities: Initial experience at 3 T

    International Nuclear Information System (INIS)

    Knobloch, G.; Gielen, M.; Lauff, M.-T.; Romano, V.C.; Schmitt, P.; Rick, M.; Kröncke, T.J.; Huppertz, A.; Hamm, B.; Wagner, M.

    2014-01-01

    Aim: To evaluate the feasibility of unenhanced electrocardiography (ECG)-gated quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) of the lower extremities at 3 T. Materials and methods: Twenty-five patients with known or suspected peripheral arterial disease underwent ECG-gated QISS-MRA and contrast-enhanced MRA (CE-MRA) at 3 T. Two independent readers performed a per-segment evaluation of the MRA datasets. Image quality was rated on a four-point scale (1 = excellent to 4 = non-diagnostic; presented as medians with interquartile range). Diagnostic performance of QISS-MRA was evaluated using CE-MRA as the reference standard. Results: QISS-MRA and CE-MRA of all patients were considered for analysis, resulting in 807 evaluated vessel segments for each MRA technique. Readers 1 and 2 rated image quality of QISS-MRA as diagnostic in 97.3% and 97% of the vessel segments, respectively. CE-MRA was rated diagnostic in all vessel segments. Image quality of the proximal vessel segments, including the infrarenal aorta, iliac arteries, and common femoral artery, was significantly lower on QISS-MRA compared to CE-MRA [image quality score across readers: 2 (1,3) versus 1 (1,1) p < 0.001]. In the more distal vessel segments, image quality of QISS-MRA was excellent and showed no significant difference compared to CE-MRA [image quality score across readers: 1 (1,1) versus 1 (1,1) p = 0.036]. Diagnostic performance of QISS-MRA was as follows (across readers): sensitivity: 87.5% (95% CI: 80.2–92.4%); specificity: 96.1% (95% CI: 93.6–97.6%); diagnostic accuracy: 94.9% (95% CI: 92.6–96.5%). Conclusions: QISS-MRA of the lower extremities is feasible at 3 T and provides high image quality, especially in the distal vessel segments

  19. Blind Source Separation of Event-Related EEG/MEG.

    Science.gov (United States)

    Metsomaa, Johanna; Sarvas, Jukka; Ilmoniemi, Risto Juhani

    2017-09-01

    Blind source separation (BSS) can be used to decompose complex electroencephalography (EEG) or magnetoencephalography data into simpler components based on statistical assumptions without using a physical model. Applications include brain-computer interfaces, artifact removal, and identifying parallel neural processes. We wish to address the issue of applying BSS to event-related responses, which is challenging because of nonstationary data. We introduce a new BSS approach called momentary-uncorrelated component analysis (MUCA), which is tailored for event-related multitrial data. The method is based on approximate joint diagonalization of multiple covariance matrices estimated from the data at separate latencies. We further show how to extend the methodology for autocovariance matrices and how to apply BSS methods suitable for piecewise stationary data to event-related responses. We compared several BSS approaches by using simulated EEG as well as measured somatosensory and transcranial magnetic stimulation (TMS) evoked EEG. Among the compared methods, MUCA was the most tolerant one to noise, TMS artifacts, and other challenges in the data. With measured somatosensory data, over half of the estimated components were found to be similar by MUCA and independent component analysis. MUCA was also stable when tested with several input datasets. MUCA is based on simple assumptions, and the results suggest that MUCA is robust with nonideal data. Event-related responses and BSS are valuable and popular tools in neuroscience. Correctly designed BSS is an efficient way of identifying artifactual and neural processes from nonstationary event-related data.

  20. Intra-Articular, Single-Shot Hylan G-F 20 Hyaluronic Acid Injection Compared with Corticosteroid in Knee Osteoarthritis: A Double-Blind, Randomized Controlled Trial.

    Science.gov (United States)

    Tammachote, Nattapol; Kanitnate, Supakit; Yakumpor, Thanasak; Panichkul, Phonthakorn

    2016-06-01

    The treatment of knee osteoarthritis with hyaluronic acid or corticosteroid injection has been widely used. The purpose of this study was to compare the efficacy of hyaluronic acid (hylan G-F 20) with triamcinolone acetonide as a single intra-articular injection for knee osteoarthritis. This study was a prospective, randomized, double-blind clinical trial. Participants with symptomatic knee osteoarthritis were recruited. They were randomized to receive a single-shot, intra-articular injection of either 6 mL of hylan G-F 20 or 6 mL of a solution comprising 1 mL of 40-mg triamcinolone acetonide and 5 mL of 1% lidocaine with epinephrine. The primary outcomes were knee pain severity, knee function, and range of motion at 6 months. Ninety-nine patients were assessed before injection and underwent a 6-month follow-up. Patients and evaluators were blinded. Multilevel regression models were used to estimate differences between the groups. At the 6-month follow-up, compared with patients who took hylan G-F 20, patients who took triamcinolone acetonide had similar improvement in knee pain, knee function, and range of motion. The difference in mean outcome scores between groups was, with regard to knee pain, a visual analog scale (VAS) score of 3 points (95% confidence interval [95% CI], -6 to 11 points); with regard to knee function, a modified Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score of 0 points (95% CI, -8 to 6 points); and, with regard to range of motion, flexion of -1° (95% CI, -5° to 2°) and extension of 0° (95% CI, -0.5° to 0.5°). However, patients who took triamcinolone acetonide had better pain improvement from 24 hours until 1 week after injection; the mean difference between groups with regard to the VAS score was 12 points (95% CI, 5 to 20 points; p = 0.002) at 24 hours and 9 points (95% CI, 1 to 15 points; p = 0.018) at 1 week. At 2 weeks after injection, patients who took triamcinolone acetonide also had better knee

  1. Sequential interactions-in which one player plays first and another responds-promote cooperation in evolutionary-dynamical simulations of single-shot Prisoner's Dilemma and Snowdrift games.

    Science.gov (United States)

    Laird, Robert A

    2018-05-21

    Cooperation is a central topic in evolutionary biology because (a) it is difficult to reconcile why individuals would act in a way that benefits others if such action is costly to themselves, and (b) it underpins many of the 'major transitions of evolution', making it essential for explaining the origins of successively higher levels of biological organization. Within evolutionary game theory, the Prisoner's Dilemma and Snowdrift games are the main theoretical constructs used to study the evolution of cooperation in dyadic interactions. In single-shot versions of these games, wherein individuals play each other only once, players typically act simultaneously rather than sequentially. Allowing one player to respond to the actions of its co-player-in the absence of any possibility of the responder being rewarded for cooperation or punished for defection, as in simultaneous or sequential iterated games-may seem to invite more incentive for exploitation and retaliation in single-shot games, compared to when interactions occur simultaneously, thereby reducing the likelihood that cooperative strategies can thrive. To the contrary, I use lattice-based, evolutionary-dynamical simulation models of single-shot games to demonstrate that under many conditions, sequential interactions have the potential to enhance unilaterally or mutually cooperative outcomes and increase the average payoff of populations, relative to simultaneous interactions-benefits that are especially prevalent in a spatially explicit context. This surprising result is attributable to the presence of conditional strategies that emerge in sequential games that can't occur in the corresponding simultaneous versions. Copyright © 2018 Elsevier Ltd. All rights reserved.

  2. Intracerebral Event-related Potentials to Subthreshold Target Stimuli

    Czech Academy of Sciences Publication Activity Database

    Brázdil, M.; Rektor, I.; Daniel, P.; Dufek, M.; Jurák, Pavel

    2001-01-01

    Roč. 112, č. 4 (2001), s. 650-661 ISSN 1388-2457 R&D Projects: GA ČR GA309/98/0490 Institutional research plan: CEZ:AV0Z2065902 Keywords : event-related potentials * intracerebral recordings * oddball paradigm Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery Impact factor: 1.922, year: 2001

  3. Measurement of event-related potentials and placebo

    Directory of Open Access Journals (Sweden)

    Sovilj Platon

    2014-01-01

    Full Text Available ERP is common abbreviation for event-related brain potentials, which are measured and used in clinical practice as well as in research practice. Contemporary studies of placebo effect are often based on functional neuromagnetic resonance (fMRI, positron emission tomography (PET, and event related potentials (ERP. This paper considers an ERP instrumentation system used in experimental researches of placebo effect. This instrumentation system can be divided into four modules: electrodes and cables, conditioning module, digital measurement module, and PC module for stimulations, presentations, acquisition and data processing. The experimental oddball paradigm is supported by the software of the instrumentation. [Projekat Ministarstva nauke Republike Srbije, br. TR32019 and Provincial Secretariat for Science and Technological Development of Autonomous Province of Vojvodina (Republic of Serbia under research grant No. 114-451-2723

  4. Emotion and attention : Event-related brain potential studies

    OpenAIRE

    Schupp, Harald Thomas; Flaisch, Tobias; Stockburger, Jessica; Junghöfer, Markus

    2006-01-01

    Emotional pictures guide selective visual attention. A series of event-related brain potential (ERP) studies is reviewed demonstrating the consistent and robust modulation of specific ERP components by emotional images. Specifically, pictures depicting natural pleasant and unpleasant scenes are associated with an increased early posterior negativity, late positive potential, and sustained positive slow wave compared with neutral contents. These modulations are considered to index different st...

  5. Proprioceptive event related potentials: gating and task effects

    DEFF Research Database (Denmark)

    Arnfred, Sidse M

    2005-01-01

    The integration of proprioception with vision, touch or audition is considered basic to the developmental formation of perceptions, conceptual objects and the creation of cognitive schemes. Thus, mapping of proprioceptive information processing is important in cognitive research. A stimulus...... of a brisk change of weight on a hand held load elicit a proprioceptive evoked potential (PEP). Here this is used to examine early and late information processing related to weight discrimination by event related potentials (ERP)....

  6. Fetal brain volumetry through MRI volumetric reconstruction and segmentation

    Science.gov (United States)

    Estroff, Judy A.; Barnewolt, Carol E.; Connolly, Susan A.; Warfield, Simon K.

    2013-01-01

    Purpose Fetal MRI volumetry is a useful technique but it is limited by a dependency upon motion-free scans, tedious manual segmentation, and spatial inaccuracy due to thick-slice scans. An image processing pipeline that addresses these limitations was developed and tested. Materials and methods The principal sequences acquired in fetal MRI clinical practice are multiple orthogonal single-shot fast spin echo scans. State-of-the-art image processing techniques were used for inter-slice motion correction and super-resolution reconstruction of high-resolution volumetric images from these scans. The reconstructed volume images were processed with intensity non-uniformity correction and the fetal brain extracted by using supervised automated segmentation. Results Reconstruction, segmentation and volumetry of the fetal brains for a cohort of twenty-five clinically acquired fetal MRI scans was done. Performance metrics for volume reconstruction, segmentation and volumetry were determined by comparing to manual tracings in five randomly chosen cases. Finally, analysis of the fetal brain and parenchymal volumes was performed based on the gestational age of the fetuses. Conclusion The image processing pipeline developed in this study enables volume rendering and accurate fetal brain volumetry by addressing the limitations of current volumetry techniques, which include dependency on motion-free scans, manual segmentation, and inaccurate thick-slice interpolation. PMID:20625848

  7. Neurodevelopment of Conflict Adaptation: Evidence From Event-Related Potentials

    DEFF Research Database (Denmark)

    Liu, Xiuying; Liu, Tongran; Shangguan, Fangfang

    2018-01-01

    Conflict adaptation is key in how children self-regulate and assert cognitive control in a given situation compared with a previous experience. In the current study, we analyzed event-related potentials (ERPs) to identify age-related differences in conflict adaptation. Participants of different a...... to better assimilate and accommodate potential environmental conflicts. The results may also indicate that the development of conflict adaption is affected by the specific characteristic of the different types of conflict.......Conflict adaptation is key in how children self-regulate and assert cognitive control in a given situation compared with a previous experience. In the current study, we analyzed event-related potentials (ERPs) to identify age-related differences in conflict adaptation. Participants of different...... ages (5-year-old children, 10-year-old children, and adults) were subjected to a stimulus-stimulus (S-S) conflict control task (the flanker task) and a stimulus-response (S-R) conflict control task (the Simon task). The behavioral results revealed that all age groups had reliable conflict adaptation...

  8. Strategies to improve phase-stability of ultrafast swept source optical coherence tomography for single shot imaging of transient mechanical waves at 16 kHz frame rate

    Energy Technology Data Exchange (ETDEWEB)

    Song, Shaozhen; Wei, Wei; Hsieh, Bao-Yu; Pelivanov, Ivan; O' Donnell, Matthew [Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); Shen, Tueng T.; Wang, Ruikang K., E-mail: wangrk@uw.edu [Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); Department of Ophthalmology, University of Washington, Seattle, Washington 98104 (United States)

    2016-05-09

    We present single-shot phase-sensitive imaging of propagating mechanical waves within tissue, enabled by an ultrafast optical coherence tomography (OCT) system powered by a 1.628 MHz Fourier domain mode-locked (FDML) swept laser source. We propose a practical strategy for phase-sensitive measurement by comparing the phases between adjacent OCT B-scans, where the B-scan contains a number of A-scans equaling an integer number of FDML buffers. With this approach, we show that micro-strain fields can be mapped with ∼3.0 nm sensitivity at ∼16 000 fps. The system's capabilities are demonstrated on porcine cornea by imaging mechanical wave propagation launched by a pulsed UV laser beam, promising non-contact, real-time, and high-resolution optical coherence elastography.

  9. Value of MR cisternography using three-dimensional half-fourier single-shot fast spin-echo sequences in the diagnosis of diseases related to cranial nerves VII and VIII

    Energy Technology Data Exchange (ETDEWEB)

    Yamakami, Norio [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1999-05-01

    The purpose of this study was to evaluate the value of MR cisternography using three-dimensional half-Fourier single-shot fast spin-echo sequences in the diagnosis of diseasea related to cranial nerves VII and VIII. With a 0.5-T imager, the most appropriate setting of echo time and section thickness was first assessed in five volunteers. This resulted in echo time of 250 msec and section thickness of 2 mm as the most effective parameters. Second, using echo time of 120 msec and section thickness of 1.5 mm that were available from the beginning of this study, the demonstration of four nerves within the audistory canal was assessed in seven volunteers. In all of the volunteers, the facial, cochlear, and vestibular nerves were determined with demonstration of each of superior and inferior vestibular nerves in four of them. Next, MR cisternography using the same echo time and section thickness was applied in 368 patients with suspicion of acoustic neurinoma and 14 with hemifacial spasm. In 28 of the 368 patients, MR cisternograms depicted an acoustic neurinoma that was confirmed on postcontrast T1-weighted images. Meanwhile, in five of the 14 patients with hemifacial spasm, MR cisternograms revealed a vessel compressing the root exit zone of the affected facial nerve. It is concluded that MR cisternography using three-dimensional half-Fourier single-shot fast spin-echo sequences can be a useful means for demonstrating nerves within the auditory nerve as well as for the screening of acoustic neurionoma. (author)

  10. Value of MR cisternography using three-dimensional half-fourier single-shot fast spin-echo sequences in the diagnosis of diseases related to cranial nerves VII and VIII

    International Nuclear Information System (INIS)

    Yamakami, Norio

    1999-01-01

    The purpose of this study was to evaluate the value of MR cisternography using three-dimensional half-Fourier single-shot fast spin-echo sequences in the diagnosis of diseasea related to cranial nerves VII and VIII. With a 0.5-T imager, the most appropriate setting of echo time and section thickness was first assessed in five volunteers. This resulted in echo time of 250 msec and section thickness of 2 mm as the most effective parameters. Second, using echo time of 120 msec and section thickness of 1.5 mm that were available from the beginning of this study, the demonstration of four nerves within the audistory canal was assessed in seven volunteers. In all of the volunteers, the facial, cochlear, and vestibular nerves were determined with demonstration of each of superior and inferior vestibular nerves in four of them. Next, MR cisternography using the same echo time and section thickness was applied in 368 patients with suspicion of acoustic neurinoma and 14 with hemifacial spasm. In 28 of the 368 patients, MR cisternograms depicted an acoustic neurinoma that was confirmed on postcontrast T1-weighted images. Meanwhile, in five of the 14 patients with hemifacial spasm, MR cisternograms revealed a vessel compressing the root exit zone of the affected facial nerve. It is concluded that MR cisternography using three-dimensional half-Fourier single-shot fast spin-echo sequences can be a useful means for demonstrating nerves within the auditory nerve as well as for the screening of acoustic neurionoma. (author)

  11. Event-Related Potentials and Emotion Processing in Child Psychopathology

    Directory of Open Access Journals (Sweden)

    Georgia eChronaki

    2016-04-01

    Full Text Available In recent years there has been increasing interest in the neural mechanisms underlying altered emotional processes in children and adolescents with psychopathology. This review provides a brief overview of the most up-to-date findings in the field of Event-Related Potentials (ERPs to facial and vocal emotional expressions in the most common child psychopathological conditions. In regards to externalising behaviour (i.e. ADHD, CD, ERP studies show enhanced early components to anger, reflecting enhanced sensory processing, followed by reductions in later components to anger, reflecting reduced cognitive-evaluative processing. In regards to internalising behaviour, research supports models of increased processing of threat stimuli especially at later more elaborate and effortful stages. Finally, in autism spectrum disorders abnormalities have been observed at early visual-perceptual stages of processing. An affective neuroscience framework for understanding child psychopathology can be valuable in elucidating underlying mechanisms and inform preventive intervention.

  12. Comparison of event related potentials with and without hypnagogic imagery.

    Science.gov (United States)

    Michida, N; Hayashi, M; Hori, T

    1998-04-01

    It is hypothesized that when hypnagogic imagery occurs, an appropriate attention may allocate to the imagery, resulting in the allocation of attention to the external tone stimuli being diminished. N3 amplitude of event related potentials (ERP) obtained a significant difference between the conditions with and without imagery. Arousal level of behavior and electroencephalography were not different between the conditions, therefore it is interpreted that the decrease of the N3 amplitude during imagining reflects the diminution of the allocation of attention to the external tone stimuli. Another late component of ERP, P3, did not make clear peaks in this study despite a large time constant (tau=3.2 s) used for EEG records.

  13. Probabilistic delay differential equation modeling of event-related potentials.

    Science.gov (United States)

    Ostwald, Dirk; Starke, Ludger

    2016-08-01

    "Dynamic causal models" (DCMs) are a promising approach in the analysis of functional neuroimaging data due to their biophysical interpretability and their consolidation of functional-segregative and functional-integrative propositions. In this theoretical note we are concerned with the DCM framework for electroencephalographically recorded event-related potentials (ERP-DCM). Intuitively, ERP-DCM combines deterministic dynamical neural mass models with dipole-based EEG forward models to describe the event-related scalp potential time-series over the entire electrode space. Since its inception, ERP-DCM has been successfully employed to capture the neural underpinnings of a wide range of neurocognitive phenomena. However, in spite of its empirical popularity, the technical literature on ERP-DCM remains somewhat patchy. A number of previous communications have detailed certain aspects of the approach, but no unified and coherent documentation exists. With this technical note, we aim to close this gap and to increase the technical accessibility of ERP-DCM. Specifically, this note makes the following novel contributions: firstly, we provide a unified and coherent review of the mathematical machinery of the latent and forward models constituting ERP-DCM by formulating the approach as a probabilistic latent delay differential equation model. Secondly, we emphasize the probabilistic nature of the model and its variational Bayesian inversion scheme by explicitly deriving the variational free energy function in terms of both the likelihood expectation and variance parameters. Thirdly, we detail and validate the estimation of the model with a special focus on the explicit form of the variational free energy function and introduce a conventional nonlinear optimization scheme for its maximization. Finally, we identify and discuss a number of computational issues which may be addressed in the future development of the approach. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Event-related potentials, cognition, and behavior: a biological approach.

    Science.gov (United States)

    Kotchoubey, Boris

    2006-01-01

    The prevailing cognitive-psychological accounts of event-related brain potentials (ERPs) assume that ERP components manifest information processing operations leading from stimulus to response. Since this view encounters numerous difficulties already analyzed in previous studies, an alternative view is presented here that regards cortical control of behavior as a repetitive sensorimotor cycle consisting of two phases: (i) feedforward anticipation and (ii) feedback cortical performance. This view allows us to interpret in an integrative manner numerous data obtained from very different domains of ERP studies: from biophysics of ERP waves to their relationship to the processing of language, in which verbal behavior is viewed as likewise controlled by the same two basic control processes: feedforward (hypothesis building) and feedback (hypothesis checking). The proposed approach is intentionally simplified, explaining numerous effects on the basis of few assumptions and relating several levels of analysis: neurophysiology, macroelectrical processes (i.e. ERPs), cognition and behavior. It can, therefore, be regarded as a first approximation to a general theory of ERPs.

  15. Early event related fields during visually evoked pain anticipation.

    Science.gov (United States)

    Gopalakrishnan, Raghavan; Burgess, Richard C; Plow, Ela B; Floden, Darlene P; Machado, Andre G

    2016-03-01

    Pain experience is not only a function of somatosensory inputs. Rather, it is strongly influenced by cognitive and affective pathways. Pain anticipatory phenomena, an important limitation to rehabilitative efforts in the chronic state, are processed by associative and limbic networks, along with primary sensory cortices. Characterization of neurophysiological correlates of pain anticipation, particularly during very early stages of neural processing is critical for development of therapeutic interventions. Here, we utilized magnetoencephalography to study early event-related fields (ERFs) in healthy subjects exposed to a 3 s visual countdown task that preceded a painful stimulus, a non-painful stimulus or no stimulus. We found that the first countdown cue, but not the last cue, evoked critical ERFs signaling anticipation, attention and alertness to the noxious stimuli. Further, we found that P2 and N2 components were significantly different in response to first-cues that signaled incoming painful stimuli when compared to non-painful or no stimuli. The findings indicate that early ERFs are relevant neural substrates of pain anticipatory phenomena and could be potentially serve as biomarkers. These measures could assist in the development of neurostimulation approaches aimed at curbing the negative effects of pain anticipation during rehabilitation. Copyright © 2015 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  16. Emotion and attention: event-related brain potential studies.

    Science.gov (United States)

    Schupp, Harald T; Flaisch, Tobias; Stockburger, Jessica; Junghöfer, Markus

    2006-01-01

    Emotional pictures guide selective visual attention. A series of event-related brain potential (ERP) studies is reviewed demonstrating the consistent and robust modulation of specific ERP components by emotional images. Specifically, pictures depicting natural pleasant and unpleasant scenes are associated with an increased early posterior negativity, late positive potential, and sustained positive slow wave compared with neutral contents. These modulations are considered to index different stages of stimulus processing including perceptual encoding, stimulus representation in working memory, and elaborate stimulus evaluation. Furthermore, the review includes a discussion of studies exploring the interaction of motivated attention with passive and active forms of attentional control. Recent research is reviewed exploring the selective processing of emotional cues as a function of stimulus novelty, emotional prime pictures, learned stimulus significance, and in the context of explicit attention tasks. It is concluded that ERP measures are useful to assess the emotion-attention interface at the level of distinct processing stages. Results are discussed within the context of two-stage models of stimulus perception brought out by studies of attention, orienting, and learning.

  17. Attention in essential tremor: evidence from event-related potentials.

    Science.gov (United States)

    Pauletti, C; Mannarelli, D; Locuratolo, N; Vanacore, N; De Lucia, M C; Mina, C; Fattapposta, F

    2013-07-01

    Clinically subtle executive dysfunctions have recently been described in essential tremor (ET), though the presence of attentional deficits is still unclear. We investigated the psychophysiological aspects of attention in ET, using event-related potentials (ERPs). Twenty-one non-demented patients with ET and 21 age- and sex-matched healthy controls underwent a psychophysiological evaluation. P300 components and the Contingent Negative Variation (CNV) were recorded. The latencies and amplitudes of the P3a and P3b subcomponents and CNV areas were evaluated. Possible correlations between clinical parameters and ERP data were investigated. P3a latency was significantly longer in the ET group (p attentive circuits, while the memory context-updating process appears to be spared. This selective cognitive dysfunction does not appear to interfere with the attentional set linked to the expectancy evaluated during a complex choice-reaction time task, which is preserved in ET. This multitask psychophysiological approach reveals the presence of a peculiar attentional deficit in patients with ET, thus expanding the clinical features of this disease.

  18. Agency attribution: event-related potentials and outcome monitoring.

    Science.gov (United States)

    Bednark, Jeffery G; Franz, Elizabeth A

    2014-04-01

    Knowledge about the effects of our actions is an underlying feature of voluntary behavior. Given the importance of identifying the outcomes of our actions, it has been proposed that the sensory outcomes of self-made actions are inherently different from those of externally caused outcomes. Thus, the outcomes of self-made actions are likely to be more motivationally significant for an agent. We used event-related potentials to investigate the relationship between the perceived motivational significance of an outcome and the attribution of agency in the presence of others. In our experiment, we assessed agency attribution in the presence of another agent by varying the degree of contiguity between participants' self-made actions and the sensory outcome. Specifically, we assessed the feedback correct-related positivity (fCRP) and the novelty P3 measures of an outcome's motivational significance and unexpectedness, respectively. Results revealed that both the fCRP and participants' agency attributions were significantly influenced by action-outcome contiguity. However, when action-outcome contiguity was ambiguous, novelty P3 amplitude was a reliable indicator of agency attribution. Prior agency attributions were also found to influence attribution in trials with ambiguous and low action-outcome contiguity. Participants' use of multiple cues to determine agency is consistent with the cue integration theory of agency. In addition to these novel findings, this study supports growing evidence suggesting that reinforcement processes play a significant role in the sense of agency.

  19. Volumetric composition of nanocomposites

    DEFF Research Database (Denmark)

    Madsen, Bo; Lilholt, Hans; Mannila, Juha

    2015-01-01

    is presented, using cellulose/epoxy and aluminosilicate/polylactate nanocomposites as case materials. The buoyancy method is used for the accurate measurements of materials density. The accuracy of the method is determined to be high, allowing the measured nanocomposite densities to be reported with 5...... significant figures. The plotting of the measured nanocomposite density as a function of the nanofibre weight content is shown to be a first good approach of assessing the porosity content of the materials. The known gravimetric composition of the nanocomposites is converted into a volumetric composition...

  20. Quantitative evaluation of benign and malignant vertebral fractures with diffusion-weighted MRI: what is the optimum combination of b values for ADC-based lesion differentiation with the single-shot turbo spin-echo sequence?

    Science.gov (United States)

    Geith, Tobias; Schmidt, Gerwin; Biffar, Andreas; Dietrich, Olaf; Duerr, Hans Roland; Reiser, Maximilian; Baur-Melnyk, Andrea

    2014-09-01

    The purpose of our study was to determine the optimum combination of b values for calculating the apparent diffusion coefficient (ADC) using a diffusion-weighted (DW) single-shot turbo spin-echo (TSE) sequence in the differentiation between acute benign and malignant vertebral body fractures. Twenty-six patients with osteoporotic (mean age, 69 years; range, 31.5-86.2 years) and 20 patients with malignant vertebral fractures (mean age, 63.4 years; range, 24.7-86.4 years) were studied. T1-weighted, STIR, and T2-weighted sequences were acquired at 1.5 T. A DW single-shot TSE sequence at different b values (100, 250, 400, and 600 s/mm(2)) was applied. On the DW images for each evaluated fracture, an ROI was manually adapted to the area of hyperintense signal intensity on STIR-hypointense signal on T1-weighted images. For each ROI, nine different combinations of two, three, and four b values were used to calculate the ADC using a least-squares algorithm. The Student t test and Mann-Whitney U test were used to determine significant differences between benign and malignant fractures. An ROC analysis and the Youden index were used to determine cutoff values for assessment of the highest sensitivity and specificity for the different ADC values. The positive (PPV) and negative predictive values (NPV) were also determined. All calculated ADCs (except the combination of b = 400 s/mm(2) and b = 600 s/mm(2)) showed statistically significant differences between benign and malignant vertebral body fractures, with benign fractures having higher ADCs than malignant ones. The use of higher b values resulted in lower ADCs than those calculated with low b values. The highest AUC (0.85) showed the ADCs calculated with b = 100 and 400 s/mm(2), and the second highest AUC (0.829) showed the ADCs calculated with b = 100, 250, and 400 s/mm(2). The Youden index with equal weight given to sensitivity and specificity suggests use of an ADC calculated with b = 100, 250, and 400 s/mm(2) (cutoff

  1. Iconic Meaning in Music: An Event-Related Potential Study

    Science.gov (United States)

    Luo, Qiuling; Huang, Hong; Mo, Lei

    2015-01-01

    Although there has been extensive research on the processing of the emotional meaning of music, little is known about other aspects of listeners’ experience of music. The present study investigated the neural correlates of the iconic meaning of music. Event-related potentials (ERP) were recorded while a group of 20 music majors and a group of 20 non-music majors performed a lexical decision task in the context of implicit musical iconic meaning priming. ERP analysis revealed a significant N400 effect of congruency in time window 260-510 ms following the onset of the target word only in the group of music majors. Time-course analysis using 50 ms windows indicated significant N400 effects both within the time window 410-460 ms and 460-510 ms for music majors, whereas only a partial N400 effect during time window 410-460 ms was observed for non-music majors. There was also a trend for the N400 effects in the music major group to be stronger than those in the non-major group in the sub-windows of 310-360ms and 410-460ms. Especially in the sub-window of 410-460 ms, the topographical map of the difference waveforms between congruent and incongruent conditions revealed different N400 distribution between groups; the effect was concentrated in bilateral frontal areas for music majors, but in central-parietal areas for non-music majors. These results imply probable neural mechanism differences underlying automatic iconic meaning priming of music. Our findings suggest that processing of the iconic meaning of music can be accomplished automatically and that musical training may facilitate the understanding of the iconic meaning of music. PMID:26161561

  2. Iconic Meaning in Music: An Event-Related Potential Study.

    Science.gov (United States)

    Cai, Liman; Huang, Ping; Luo, Qiuling; Huang, Hong; Mo, Lei

    2015-01-01

    Although there has been extensive research on the processing of the emotional meaning of music, little is known about other aspects of listeners' experience of music. The present study investigated the neural correlates of the iconic meaning of music. Event-related potentials (ERP) were recorded while a group of 20 music majors and a group of 20 non-music majors performed a lexical decision task in the context of implicit musical iconic meaning priming. ERP analysis revealed a significant N400 effect of congruency in time window 260-510 ms following the onset of the target word only in the group of music majors. Time-course analysis using 50 ms windows indicated significant N400 effects both within the time window 410-460 ms and 460-510 ms for music majors, whereas only a partial N400 effect during time window 410-460 ms was observed for non-music majors. There was also a trend for the N400 effects in the music major group to be stronger than those in the non-major group in the sub-windows of 310-360 ms and 410-460 ms. Especially in the sub-window of 410-460 ms, the topographical map of the difference waveforms between congruent and incongruent conditions revealed different N400 distribution between groups; the effect was concentrated in bilateral frontal areas for music majors, but in central-parietal areas for non-music majors. These results imply probable neural mechanism differences underlying automatic iconic meaning priming of music. Our findings suggest that processing of the iconic meaning of music can be accomplished automatically and that musical training may facilitate the understanding of the iconic meaning of music.

  3. Robust estimation of event-related potentials via particle filter.

    Science.gov (United States)

    Fukami, Tadanori; Watanabe, Jun; Ishikawa, Fumito

    2016-03-01

    In clinical examinations and brain-computer interface (BCI) research, a short electroencephalogram (EEG) measurement time is ideal. The use of event-related potentials (ERPs) relies on both estimation accuracy and processing time. We tested a particle filter that uses a large number of particles to construct a probability distribution. We constructed a simple model for recording EEG comprising three components: ERPs approximated via a trend model, background waves constructed via an autoregressive model, and noise. We evaluated the performance of the particle filter based on mean squared error (MSE), P300 peak amplitude, and latency. We then compared our filter with the Kalman filter and a conventional simple averaging method. To confirm the efficacy of the filter, we used it to estimate ERP elicited by a P300 BCI speller. A 400-particle filter produced the best MSE. We found that the merit of the filter increased when the original waveform already had a low signal-to-noise ratio (SNR) (i.e., the power ratio between ERP and background EEG). We calculated the amount of averaging necessary after applying a particle filter that produced a result equivalent to that associated with conventional averaging, and determined that the particle filter yielded a maximum 42.8% reduction in measurement time. The particle filter performed better than both the Kalman filter and conventional averaging for a low SNR in terms of both MSE and P300 peak amplitude and latency. For EEG data produced by the P300 speller, we were able to use our filter to obtain ERP waveforms that were stable compared with averages produced by a conventional averaging method, irrespective of the amount of averaging. We confirmed that particle filters are efficacious in reducing the measurement time required during simulations with a low SNR. Additionally, particle filters can perform robust ERP estimation for EEG data produced via a P300 speller. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. Event-related potential correlates of mindfulness meditation competence.

    Science.gov (United States)

    Atchley, R; Klee, D; Memmott, T; Goodrich, E; Wahbeh, H; Oken, B

    2016-04-21

    This cross-sectional study evaluated event-related potentials (ERPs) across three groups: naïve, novice, and experienced meditators as potential physiological markers of mindfulness meditation competence. Electroencephalographic (EEG) data were collected during a target tone detection task and a Breath Counting task. The Breath Counting task served as the mindfulness meditation condition for the novice and experienced meditator groups. Participants were instructed to respond to target tones with a button press in the first task (Tones), and then ignore the primed tones while Breath Counting. The primary outcomes were ERP responses to target tones, namely the N2 and P3, as markers of stimulus discrimination and attention, respectively. As expected, P3 amplitudes elicited by target tones were attenuated within groups during the Breath Counting task in comparison to the Tones task (pmeditator groups displayed greater change in peak-to-trough P3 amplitudes, with higher amplitudes during the Tones condition and more pronounced reductions in P3 amplitudes during the Breath Counting meditation task in comparison to the naïve group. Meditators had stronger P3 amplitude responses to target tones when instructed to attend to the tones, and a greater attenuation of P3 amplitudes when instructed to ignore the same tones during the Breath Counting task. This study introduces the idea of identifying ERP markers as a means of measuring mindfulness meditation competence, and results suggest this may be a valid approach. This information has the potential to improve mindfulness meditation interventions by allowing objective assessment of mindfulness meditation quality. Published by Elsevier Ltd.

  5. Differentiation between hepatic haemangiomas and cysts with an inversion recovery single-shot turbo spin-echo (SSTSE) sequence using the TI nulling value of hepatic haemangioma with sensitivity encoding

    International Nuclear Information System (INIS)

    Katada, Yoshiaki; Nozaki, Miwako; Yasumoto, Mayumi; Ishii, Chikako; Tanaka, Hiroshi; Nakamoto, Kazuya; Ohashi, Isamu

    2010-01-01

    To evaluate the additional value of inversion recovery (IR) single-shot turbo spin-echo (SSTSE) imaging with sensitivity encoding (SENSE) using the inversion time (TI) value of hepatic haemangioma as a supplement to conventional T2-weighted turbo spin-echo (TSE) imaging for the discrimination of hepatic haemangiomas and cysts. A total of 134 lesions (77 hepatic haemangiomas, 57 hepatic cysts) in 59 patients were evaluated. Three readers evaluated these images and used a five-point scale to evaluate the lesion status. A receiver operating characteristic (ROC) analysis and 2 x 2 table analysis were used. The ROC analysis for all the readers and all the cases revealed a significantly higher area under the curve (AUC) for the combination of moderately and heavily T2-weighted TSE with IR-SSTSE images (0.945) than for moderately and heavily T2-weighted TSE images alone (0.894) (P < 0.001). For the combination of T2-weighted TSE with IR-SSTSE versus T2-weighted TSE alone, the 2 x 2 table analysis revealed a higher true-positive rate; this difference was statistically significant (P < 0.0001). The introduction of IR-SSTSE with SENSE sequences significantly improves the diagnostic accuracy of the differentiation of hepatic haemangioma and cysts while increasing the time required for routine abdominal imaging by only 20 s. (orig.)

  6. Coaxial volumetric velocimetry

    Science.gov (United States)

    Schneiders, Jan F. G.; Scarano, Fulvio; Jux, Constantin; Sciacchitano, Andrea

    2018-06-01

    This study describes the working principles of the coaxial volumetric velocimeter (CVV) for wind tunnel measurements. The measurement system is derived from the concept of tomographic PIV in combination with recent developments of Lagrangian particle tracking. The main characteristic of the CVV is its small tomographic aperture and the coaxial arrangement between the illumination and imaging directions. The system consists of a multi-camera arrangement subtending only few degrees solid angle and a long focal depth. Contrary to established PIV practice, laser illumination is provided along the same direction as that of the camera views, reducing the optical access requirements to a single viewing direction. The laser light is expanded to illuminate the full field of view of the cameras. Such illumination and imaging conditions along a deep measurement volume dictate the use of tracer particles with a large scattering area. In the present work, helium-filled soap bubbles are used. The fundamental principles of the CVV in terms of dynamic velocity and spatial range are discussed. Maximum particle image density is shown to limit tracer particle seeding concentration and instantaneous spatial resolution. Time-averaged flow fields can be obtained at high spatial resolution by ensemble averaging. The use of the CVV for time-averaged measurements is demonstrated in two wind tunnel experiments. After comparing the CVV measurements with the potential flow in front of a sphere, the near-surface flow around a complex wind tunnel model of a cyclist is measured. The measurements yield the volumetric time-averaged velocity and vorticity field. The measurements of the streamlines in proximity of the surface give an indication of the skin-friction lines pattern, which is of use in the interpretation of the surface flow topology.

  7. Single-shot pectoral plane (PECs I and PECs II) blocks versus continuous local anaesthetic infusion analgesia or both after non-ambulatory breast-cancer surgery: a prospective, randomised, double-blind trial.

    Science.gov (United States)

    O'Scanaill, P; Keane, S; Wall, V; Flood, G; Buggy, D J

    2018-04-01

    Pectoral plane blocks (PECs) are increasingly used in analgesia for patients undergoing breast surgery, and were recently found to be at least equivalent to single-shot paravertebral anaesthesia. However, there are no data comparing PECs with the popular practice of continuous local anaesthetic wound infusion (LA infusion) analgesia for breast surgery. Therefore, we compared the efficacy and safety of PECs blocks with LA infusion, or a combination of both in patients undergoing non-ambulatory breast-cancer surgery. This single-centre, prospective, randomised, double-blind trial analysed 45 women to receive either PECs blocks [levobupivacaine 0.25%, 10 ml PECs I and levobupivacaine 0.25%, 20 ml PECs II (PECs group); LA infusion catheter (levobupivacaine 0.1% at 10 ml h -1 for 24 h (LA infusion group); or both (PECs and LA infusion)]. The primary outcome measure was area under the curve of the pain verbal rating score whilst moving vs time (AUC) over 24 h. Secondary outcomes included total opioid consumption at 24 h. AUC moving was mean (SD) 71 (34) mm h -1 vs 58 (41) vs 23 (20) in PECs, LA infusion, and both, respectively; P=0.002. AUC at rest was also significantly lower in patients receiving both. The total 24 h opioid consumption [median (25-75%)] was 14 mg (9-26) vs 11 (8-24) vs 9 (5-11); P=0.4. No adverse events were observed. The combination of both pre-incisional PECs blocks and postoperative LA infusion provides better analgesia over 24 h than either technique alone after non-ambulatory breast-cancer surgery. NCT 03024697. Copyright © 2018 British Journal of Anaesthesia. Published by Elsevier Ltd. All rights reserved.

  8. Single-Shot Echo-Planar Diffusion-Weighted MR Imaging at 3T and 1.5T for Differentiation of Benign Vertebral Fracture Edema and Tumor Infiltration

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hee Jin; Lee, So Yeon; Rho, Myung Ho; Chung, Eun Chul; Kim, Mi Sung; Kwon, Heon Ju; Youn, In Young [Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul 03181 (Korea, Republic of)

    2016-11-01

    To compare the apparent diffusion coefficient (ADC) value using single-shot echo-planar imaging sequences at 3T and 1.5T for differentiation of benign fracture edema and tumor infiltration of the vertebral body. A total of 46 spinal examinations were included in the 1.5T MRI group, and a total of 40 spinal examinations were included in the 3T MRI group. The ADC values of the lesion were measured and calculated. The diagnostic performance of the conventional MR image containing sagittal T2-weighted fat saturated image and each diffusion weighted image (DWI) with an ADC value with different b values were evaluated. The mean ADC value of the benign lesions was higher than that of the malignant lesions on 1.5T and 3T (p < 0.05). The sensitivity of the diagnostic performance was higher with an additional DWI in both 1.5T and 3T, but the sensitivities were similar with the addition of b values of 400 and 1000. The specificities of the diagnostic performances did not show significant differences (p value > 0.05). The diagnostic accuracies were higher when either of the DWIs (b values of 400 and 1000) was added to routine MR image for 1.5T and 3T. Statistical differences between 1.5T and 3T or between b values of 400 and 1000 were not seen. The ADC values of the benign lesions were significantly higher than those of the malignant lesions on 1.5T and 3T. There was no statistically significant difference in the diagnostic performances when either of the DWIs (b values of 400 and 1000) was added to the routine MR image for 1.5T and 3T.

  9. What is the most suitable MR signal index for quantitative evaluation of placental function using Half-Fourier acquisition single-shot turbo spin-echo compared with T2-relaxation time?

    Science.gov (United States)

    Kameyama, Kyoko Nakao; Kido, Aki; Himoto, Yuki; Moribata, Yusaku; Minamiguchi, Sachiko; Konishi, Ikuo; Togashi, Kaori

    2018-06-01

    Background Half-Fourier acquisition single-shot turbo spin-echo (HASTE) imaging is now widely used for placental and fetal imaging because of its rapidity and low sensitivity to fetal movement. If placental dysfunction is also predicted by quantitative value obtained from HASTE image, then it might be beneficial for evaluating placental wellbeing. Purpose To ascertain the most suitable magnetic resonance (MR) signal indexes reflecting placental function using HASTE imaging. Material and Methods This retrospective study included 37 consequent patients who had given informed consent to MR imaging (MRI) examinations. All had undergone MRI examinations between February 2014 and June 2015. First, the correlation between T2-relaxation time of normal placenta and gestational age (GA) was examined. Second, correlation between signal intensity ratios (SIRs) using HASTE imaging and placental T2-relaxation time were assessed. The SIRs were calculated using placental signal intensity (SI) relative to the SI of the amniotic fluid, fetal ocular globes, gastric fluid, bladder, maternal psoas major muscles, and abdominal subcutaneous adipose tissue. Results Among the 37 patients, the correlation between T2-relaxation time of the 25 normal placentas and GA showed a moderately strong correlation (Spearman rho = -0.447, P = 0.0250). The most significant correlation with placental T2-relaxation time was observed with the placental SIR relative to the maternal psoas major muscles (SIR pl./psoas muscle ) (Spearman rho = -0.531, P = 0.0007). Conclusion This study revealed that SIR pl./psoas muscle showed the best correlation to placental T2-relaxation time. Results show that SIR pl./psoas muscle might be optimal as a clinically available quantitative index of placental function.

  10. Blind Separation of Event-Related Brain Responses into Independent Components

    National Research Council Canada - National Science Library

    Makeig, Scott

    1996-01-01

    .... We report here a method for the blind separation of event-related brain responses into spatially stationary and temporally independent subcomponents using an Independent Component Analysis algorithm...

  11. Age, intelligence, and event-related brain potentials during late childhood: A longitudinal study.

    NARCIS (Netherlands)

    Molenaar, P.C.M.; Molen, M.W.; Stauder, J.E.A.

    2003-01-01

    he relation between event-related brain activity, age, and intelligence was studied using a visual oddball task presented longitudinally to girls at 9, 10, and 11 years of age. The event-related brain potential (ERP) components showed typical gradual decrements in latency and amplitude with

  12. Post-operative analgesia following total knee arthroplasty: comparison of low-dose intrathecal morphine and single-shot ultrasound-guided femoral nerve block: a randomized, single blinded, controlled study.

    Science.gov (United States)

    Frassanito, L; Vergari, A; Zanghi, F; Messina, A; Bitondo, M; Antonelli, M

    2010-07-01

    .7 mg vs 13.6 mg. However, the difference in the opiate consumption was not statistically different (p value = 0.06). Thirteen patients in ITM group experienced itching, only 5 in FNB group. We did not find any difference in the two treatment groups in the use of antiemetic and antipruritic medication. No cases of respiratory depression was recorded. Our results show that low dose of intrathecal morphine may be safe and more efficient than single-shot femoral nerve block for post-operative analgesia after total knee arthroplasty.

  13. Readout-segmented echo-planar imaging improves the image quality of diffusion-weighted MR imaging in rectal cancer: Comparison with single-shot echo-planar diffusion-weighted sequences

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Chun-chao; Liu, Xi; Peng, Wan-lin; Li, Lei; Zhang, Jin-ge [Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Meng, Wen-jian; Deng, Xiang-bing [Department of Gastrointestinal Surgery, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Zuo, Pan-li [Siemens Healthcare, MR Collaborations NE Asia, 100010, Beijing (China); Li, Zhen-lin, E-mail: lzlcd01@126.com [Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China)

    2016-10-15

    Purpose: To determine whether readout-segmented echo-planar imaging (rs-EPI) diffusion-weighted imaging (DWI) can improve the image quality in patients with rectal cancer compared with single-shot echo-planar imaging (ss-EPI) DWI using 3.0 T magnetic resonance (MR) imaging. Materials and methods: This study was approved by the Institutional Review Board, and informed consent was obtained from all patients. Seventy-one patients with rectal cancer were enrolled in this study. For all patients, both rs-EPI and ss-EPI DWI were performed using a 3T MR scanner. Two radiologists independently assessed the overall image quality, lesion conspicuity, geometric distortion and distinction of anatomical structures. The signal-to-noise ratio (SNR), lesion contrast, contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) were also measured. Comparisons of the quantitative and qualitative parameters between the two sequences were performed using the paired t-test and the Wilcoxon signed rank test. Results: The scores of overall image quality, lesion conspicuity, geometric distortion and distinction of anatomical structures of rs-EPI were all significantly higher than those of ss-EPI (all p < 0.05). The SNR and CNR were higher in rs-EPI than those in ss-EPI (all p < 0.05). There was no significant difference between ss-EPI and rs-EPI with regard to ROI size and mean ADCs of the tumour (p = 0.574 and p = 0.479, respectively), but the mean ADC of the normal tissue was higher in rs-EPI than in ss-EPI (1.73 ± 0.30 × 10{sup −3} mm{sup 2}/s vs. 1.60 ± 0.31 × 10{sup −3} mm{sup 2}/s, p = 0.001). Conclusions: DW imaging based on readout-segmented echo-planar imaging is a clinically useful technique to improve the image quality for the purpose of evaluating lesions in patients with rectal tumours.

  14. Can a single-shot black-blood T2-weighted spin-echo echo-planar imaging sequence with sensitivity encoding replace the respiratory-triggered turbo spin-echo sequence for the liver? An optimization and feasibility study.

    Science.gov (United States)

    Hussain, Shahid M; De Becker, Jan; Hop, Wim C J; Dwarkasing, Soendersing; Wielopolski, Piotr A

    2005-03-01

    To optimize and assess the feasibility of a single-shot black-blood T2-weighted spin-echo echo-planar imaging (SSBB-EPI) sequence for MRI of the liver using sensitivity encoding (SENSE), and compare the results with those obtained with a T2-weighted turbo spin-echo (TSE) sequence. Six volunteers and 16 patients were scanned at 1.5T (Philips Intera). In the volunteer study, we optimized the SSBB-EPI sequence by interactively changing the parameters (i.e., the resolution, echo time (TE), diffusion weighting with low b-values, and polarity of the phase-encoding gradient) with regard to distortion, suppression of the blood signal, and sensitivity to motion. The influence of each change was assessed. The optimized SSBB-EPI sequence was applied in patients (N = 16). A number of items, including the overall image quality (on a scale of 1-5), were used for graded evaluation. In addition, the signal-to-noise ratio (SNR) of the liver was calculated. Statistical analysis was carried out with the use of Wilcoxon's signed rank test for comparison of the SSBB-EPI and TSE sequences, with P = 0.05 considered the limit for significance. The SSBB-EPI sequence was improved by the following steps: 1) less frequency points than phase-encoding steps, 2) a b-factor of 20, and 3) a reversed polarity of the phase-encoding gradient. In patients, the mean overall image quality score for the optimized SSBB-EPI (3.5 (range: 1-4)) and TSE (3.6 (range: 3-4)), and the SNR of the liver on SSBB-EPI (mean +/- SD = 7.6 +/- 4.0) and TSE (8.9 +/- 4.6) were not significantly different (P > .05). Optimized SSBB-EPI with SENSE proved to be feasible in patients, and the overall image quality and SNR of the liver were comparable to those achieved with the standard respiratory-triggered T2-weighted TSE sequence. (c) 2005 Wiley-Liss, Inc.

  15. Introducing the event related fixed interval area (ERFIA) multilevel technique: a method to analyze the complete epoch of event-related potentials at single trial level

    NARCIS (Netherlands)

    Vossen, C.J.; Vossen, H.G.M.; Marcus, M.A.E.; van Os, J.; Lousberg, R.

    2013-01-01

    In analyzing time-locked event-related potentials (ERPs), many studies have focused on specific peaks and their differences between experimental conditions. In theory, each latency point after a stimulus contains potentially meaningful information, regardless of whether it is peak-related. Based on

  16. Functionally Independent Components of the Late Positive Event-Related Potential During Visual Spatial Attention

    National Research Council Canada - National Science Library

    Makeig, Scott; Westeifleld, Marissa; Jung, Tzyy-Ping; Covington, James; Townsend, Jeanne; Sejnowski, Terrence J; Courchesne, Eric

    1999-01-01

    Human event-related potentials (ERPs) were recorded from 10 subjects presented with visual target and nontarget stimuli at five screen locations and responding to targets presented at one of the locations...

  17. Comparison of Diffusion-Weighted Imaging in the Human Brain Using Readout-Segmented EPI and PROPELLER Turbo Spin Echo With Single-Shot EPI at 7 T MRI.

    Science.gov (United States)

    Kida, Ikuhiro; Ueguchi, Takashi; Matsuoka, Yuichiro; Zhou, Kun; Stemmer, Alto; Porter, David

    2016-07-01

    The purpose of the present study was to compare periodically rotated overlapping parallel lines with enhanced reconstruction-type turbo spin echo diffusion-weighted imaging (pTSE-DWI) and readout-segmented echo planar imaging (rsEPI-DWI) with single-shot echo planar imaging (ssEPI-DWI) in a 7 T human MR system. We evaluated the signal-to-noise ratio (SNR), image distortion, and apparent diffusion coefficient values in the human brain. Six healthy volunteers were included in this study. The study protocol was approved by our institutional review board. All measurements were performed at 7 T using pTSE-DWI, rsEPI-DWI, and ssEPI-DWI sequences. The spatial resolution was 1.2 × 1.2 mm in-plane with a 3-mm slice thickness. Signal-to-noise ratio was measured using 2 scans. The ssEPI-DWI sequence showed significant image blurring, whereas pTSE-DWI and rsEPI-DWI sequences demonstrated high image quality with low geometrical distortion compared with reference T2-weighted, turbo spin echo images. Signal loss in ventral regions near the air-filled paranasal sinus/nasal cavity was found in ssEPI-DWI and rsEPI-DWI but not pTSE-DWI. The apparent diffusion coefficient values for ssEPI-DWI were 824 ± 17 × 10 and 749 ± 25 × 10 mm/s in the gray matter and white matter, respectively; the values obtained for pTSE-DWI were 798 ± 21 × 10 and 865 ± 40 × 10 mm/s; and the values obtained for rsEPI-DWI were 730 ± 12 × 10 and 722 ± 25 × 10 mm/s. The pTSE-DWI images showed no additional distortion comparison to the T2-weighted images, but had a lower SNR than ssEPI-DWI and rsEPI-DWI. The rsEPI-DWI sequence provided high-quality images with minor distortion and a similar SNR to ssEPI-DWI. Our results suggest that the benefits of the rsEPI-DWI and pTSE-DWI sequences, in terms of SNR, image quality, and image distortion, appear to outweigh those of ssEPI-DWI. Thus, pTSE-DWI and rsEPI-DWI at 7 T have great potential use for clinical diagnoses. However, it is noteworthy that both

  18. An event-related potential study on memory search for color

    OpenAIRE

    Miyatani, Makoto; Nakao, Takasi; Ohkawa, Kaori; Sanderson, Nicholas S. R.; Takumi, Ken

    2002-01-01

    The present study focused on memory search processes in nonverbal working memory. Event-related potentials (ERPs) were recorded while subjects engaged in two memory search tasks. Effects of memory set size on event-related potentials were compared between when memory sets consisted of one or four alphabets and when one to three unvocable color patches composed memory sets. In a letter search task, increase of memory set size caused the enlargement of negativities of ERPs between 250 and 450 m...

  19. Efficacy of triplet regimen antiemetic therapy for chemotherapy-induced nausea and vomiting (CINV) in bone and soft tissue sarcoma patients receiving highly emetogenic chemotherapy, and an efficacy comparison of single-shot palonosetron and consecutive-day granisetron for CINV in a randomized, single-blinded crossover study

    International Nuclear Information System (INIS)

    Kimura, Hiroaki; Yamamoto, Norio; Shirai, Toshiharu; Nishida, Hideji; Hayashi, Katsuhiro; Tanzawa, Yoshikazu; Takeuchi, Akihiko; Igarashi, Kentaro; Inatani, Hiroyuki; Shimozaki, Shingo; Kato, Takashi; Aoki, Yu; Higuchi, Takashi; Tsuchiya, Hiroyuki

    2015-01-01

    The first aim of this study was to evaluate combination antiemetic therapy consisting of 5-HT 3 receptor antagonists, neurokinin-1 receptor antagonists (NK-1RAs), and dexamethasone for multiple high emetogenic risk (HER) anticancer agents in bone and soft tissue sarcoma. The second aim was to compare the effectiveness of single-shot palonosetron and consecutive-day granisetron in a randomized, single-blinded crossover study. A single randomization method was used to assign eligible patients to the palonosetron or granisetron arm. Patients in the palonosetron arm received a palonosetron regimen during the first and third chemotherapy courses and a granisetron regimen during the second and fourth courses. All patients received NK-1RA and dexamethasone. Patients receiving the palonosetron regimen were administered 0.75 mg palonosetron on day 1, and patients receiving the granisetron regimen were administered 3 mg granisetron twice daily on days 1 through 5. All 24 patients in this study received at least 4 chemotherapy courses. A total of 96 courses of antiemetic therapy were evaluated. Overall, the complete response CR rate (no emetic episodes and no rescue medication use) was 34%, while the total control rate (a CR plus no nausea) was 7%. No significant differences were observed between single-shot palonosetron and consecutive-day granisetron. Antiemetic therapy with a 3-drug combination was not sufficient to control chemotherapy-induced nausea and vomiting (CINV) during chemotherapy with multiple HER agents for bone and soft tissue sarcoma. This study also demonstrated that consecutive-day granisetron was not inferior to single-shot palonosetron for treating CINV

  20. Efficacy of triplet regimen antiemetic therapy for chemotherapy-induced nausea and vomiting (CINV) in bone and soft tissue sarcoma patients receiving highly emetogenic chemotherapy, and an efficacy comparison of single-shot palonosetron and consecutive-day granisetron for CINV in a randomized, single-blinded crossover study.

    Science.gov (United States)

    Kimura, Hiroaki; Yamamoto, Norio; Shirai, Toshiharu; Nishida, Hideji; Hayashi, Katsuhiro; Tanzawa, Yoshikazu; Takeuchi, Akihiko; Igarashi, Kentaro; Inatani, Hiroyuki; Shimozaki, Shingo; Kato, Takashi; Aoki, Yu; Higuchi, Takashi; Tsuchiya, Hiroyuki

    2015-03-01

    The first aim of this study was to evaluate combination antiemetic therapy consisting of 5-HT3 receptor antagonists, neurokinin-1 receptor antagonists (NK-1RAs), and dexamethasone for multiple high emetogenic risk (HER) anticancer agents in bone and soft tissue sarcoma. The second aim was to compare the effectiveness of single-shot palonosetron and consecutive-day granisetron in a randomized, single-blinded crossover study. A single randomization method was used to assign eligible patients to the palonosetron or granisetron arm. Patients in the palonosetron arm received a palonosetron regimen during the first and third chemotherapy courses and a granisetron regimen during the second and fourth courses. All patients received NK-1RA and dexamethasone. Patients receiving the palonosetron regimen were administered 0.75 mg palonosetron on day 1, and patients receiving the granisetron regimen were administered 3 mg granisetron twice daily on days 1 through 5. All 24 patients in this study received at least 4 chemotherapy courses. A total of 96 courses of antiemetic therapy were evaluated. Overall, the complete response CR rate (no emetic episodes and no rescue medication use) was 34%, while the total control rate (a CR plus no nausea) was 7%. No significant differences were observed between single-shot palonosetron and consecutive-day granisetron. Antiemetic therapy with a 3-drug combination was not sufficient to control chemotherapy-induced nausea and vomiting (CINV) during chemotherapy with multiple HER agents for bone and soft tissue sarcoma. This study also demonstrated that consecutive-day granisetron was not inferior to single-shot palonosetron for treating CINV. © 2014 The Authors. Cancer Medicine published by John Wiley & Sons Ltd.

  1. Event-related potentials dissociate perceptual from response-related age effects in visual search

    DEFF Research Database (Denmark)

    Wiegand, Iris; Müller, Hermann J.; Finke, Kathrin

    2013-01-01

    measures with lateralized event-related potentials of younger and older adults performing a compound-search task, in which the target-defining dimension of a pop-out target (color/shape) and the response-critical target feature (vertical/horizontal stripes) varied independently across trials. Slower...... responses in older participants were associated with age differences in all analyzed event-related potentials from perception to response, indicating that behavioral slowing originates from multiple stages within the information-processing stream. Furthermore, analyses of carry-over effects from one trial...

  2. The "Mozart effect": an electroencephalographic analysis employing the methods of induced event-related desynchronization/synchronization and event-related coherence.

    Science.gov (United States)

    Jausovec, Norbert; Habe, Katarina

    2003-01-01

    The event-related responses of 18 individuals were recorded while they were listening to 3 music clips of 6 s duration which were repeated 30 times each. The music clips differed in the level of their complex structure, induced mood, musical tempo and prominent frequency. They were taken from Mozart's sonata (K. 448), and Brahms' Hungarian dance (no. 5). The third clip was a simplified version of the theme taken from Haydn's symphony (no. 94) played by a computer synthesizer. Significant differences in induced event-related desynchronization between the 3 music clips were only observed in the lower-1 alpha band which is related to attentional processes. A similar pattern was observed for the coherence measures. While respondents listened to the Mozart clip, coherence in the lower alpha bands increased more, whereas in the gamma band a less pronounced increase was observed as compared with the Brahms and Haydn clips. The clustering of the three clips based on EEG measures distinguished between the Mozart clip on the one hand, and the Haydn and Brahms clips on the other, even though the Haydn and Brahms clips were at the opposite extremes with regard to the mood they induced in listeners, musical tempo, and complexity of structure. This would suggest that Mozart's music--with no regard to the level of induced mood, musical tempo and complexity--influences the level of arousal. It seems that modulations in the frequency domain of Mozart's sonata have the greatest influence on the reported neurophysiological activity.

  3. Kilohertz VLIF (volumetric laser induced fluorescence) measurements in a seeded free gas-phase jet in the transitionally turbulent flow regime

    Science.gov (United States)

    Wu, Yue; Xu, Wenjiang; Ma, Lin

    2018-03-01

    This paper reports the demonstration of instantaneous three-dimension (3D) measurements in turbulent flows at repetition rates up to 10 kHz using VLIF (volumetric laser induced fluorescence). The measurements were performed based on the LIF signal of iodine (I2) vapor seeded in the flow. The LIF signals of I2 vapor were generated volumetrically by a thick laser slab and then simultaneously captured by a total of seven cameras from different perspectives, based on which a 3D tomographic reconstruction was performed to obtain the 3D distribution of I2 vapor concentration. Single-shot measurements obtained in a duration of hundreds of nanoseconds (limited by the pulse duration of the excitation laser) were demonstrated in a 50 × 50 × 50 mm3 at a repetition rate up to 10 kHz. These measurements demonstrated the feasibility and potential of VLIF for resolving the 4D spatiotemporal dynamics of turbulent flows. Based on the experimental results obtained, this work also studied the VLIF signal level and its effects on the reconstruction accuracy under different the measurement conditions, illustrating the capabilities and limitations of performing high speed VLIF measurements.

  4. Effects of Grammatical Categories on Children's Visual Language Processing: Evidence from Event-Related Brain Potentials

    Science.gov (United States)

    Weber-Fox, Christine; Hart, Laura J.; Spruill, John E., III

    2006-01-01

    This study examined how school-aged children process different grammatical categories. Event-related brain potentials elicited by words in visually presented sentences were analyzed according to seven grammatical categories with naturally varying characteristics of linguistic functions, semantic features, and quantitative attributes of length and…

  5. Spoken sentence comprehension in aphasia: Event-related potential evidence for a lexical integration deficit

    NARCIS (Netherlands)

    Swaab, T.Y.; Brown, C.; Hagoort, P.

    1997-01-01

    In this study the N400 component of the event-related potential was used to investigate spoken sentence understanding in Broca's and Wernicke's aphasics. The aim of the study was to determine whether spoken sentence comprehension problems in these patients might result from a deficit in the on-line

  6. Tangential derivative mapping of axial MEG applied to event-related desynchronization research

    NARCIS (Netherlands)

    Bastiaansen, M.C.M.; Knösche, T.R.

    2000-01-01

    Objectives: A problem with the topographic mapping of MEG data recorded with axial gradiometers is that field extrema are measured at sensors located at either side of a neuronal generator instead of at sensors directly above the source. This is problematic for the computation of event-related

  7. Cognitive Association Formation in Episodic Memory: Evidence from Event-Related Potentials

    Science.gov (United States)

    Kim, Alice S. N.; Vallesi, Antonino; Picton, Terence W.; Tulving, Endel

    2009-01-01

    The present study focused on the processes underlying cognitive association formation by investigating subsequent memory effects. Event-related potentials were recorded as participants studied pairs of words, presented one word at a time, for later recall. The findings showed that a frontal-positive late wave (LW), which occurred 1-1.6 s after the…

  8. Event-Related EEG Oscillations to Semantically Unrelated Words in Normal and Learning Disabled Children

    Science.gov (United States)

    Fernandez, Thalia; Harmony, Thalia; Mendoza, Omar; Lopez-Alanis, Paula; Marroquin, Jose Luis; Otero, Gloria; Ricardo-Garcell, Josefina

    2012-01-01

    Learning disabilities (LD) are one of the most frequent problems for elementary school-aged children. In this paper, event-related EEG oscillations to semantically related and unrelated pairs of words were studied in a group of 18 children with LD not otherwise specified (LD-NOS) and in 16 children with normal academic achievement. We propose that…

  9. Children's Performance on Pseudoword Repetition Depends on Auditory Trace Quality: Evidence from Event-Related Potentials.

    Science.gov (United States)

    Ceponiene, Rita; Service, Elisabet; Kurjenluoma, Sanna; Cheour, Marie; Naatanen, Risto

    1999-01-01

    Compared the mismatch-negativity (MMN) component of auditory event-related brain potentials to explore the relationship between phonological short-term memory and auditory-sensory processing in 7- to 9-year olds scoring the highest and lowest on a pseudoword repetition test. Found that high and low repeaters differed in MMN amplitude to speech…

  10. The effects of cortisol administration on approach-avoidance behavior: An event-related potential study

    NARCIS (Netherlands)

    Peer, J.M. van; Roelofs, K.; Rotteveel, M.; Dijk, J.G. van; Spinhoven, P.; Ridderinkhof, K.R.

    2007-01-01

    We investigated the effects of cortisol administration (50 mg) on approach and avoidance tendencies in low and high trait avoidant healthy young men. Event-related brain potentials (ERPs) were measured during a reaction time task, in which participants evaluated the emotional expression of

  11. Event-related Potentials Reflecting the Processing of Phonological Constraint Violations

    NARCIS (Netherlands)

    Domahs, Ulrike; Kehrein, Wolfgang; Knaus, Johannes; Wiese, Richard; Schlesewsky, Matthias

    2009-01-01

    Flow are violations of phonological constraints processed in word comprehension? The present article reports the results of ail event-related potentials (ERP) Study oil a phonological constraint of German that disallows identical segments within it syllable or word (CC(i)VC(i)). We examined three

  12. Event-related potentials reflecting the processing of phonological constraint violations

    NARCIS (Netherlands)

    Domahs, U.; Kehrein, W.; Knaus, J.; Wiese, R.; Schlesewsky, M.

    2009-01-01

    How are violations of phonological constraints processed in word comprehension? The present article reports the results of an event-related potentials (ERP) study on a phonological constraint of German that disallows identical segments within a syllable or word (CC iVCi). We examined three types of

  13. Snake scales, partial exposure, and the Snake Detection Theory: A human event-related potentials study

    NARCIS (Netherlands)

    J.W. van Strien (Jan); L.A. Isbell (Lynne A.)

    2017-01-01

    textabstractStudies of event-related potentials in humans have established larger early posterior negativity (EPN) in response to pictures depicting snakes than to pictures depicting other creatures. Ethological research has recently shown that macaques and wild vervet monkeys respond strongly to

  14. An event-related brain potential correlate of visual short-term memory

    NARCIS (Netherlands)

    Klaver, Peter; Talsma, D.; Wijers, Albertus; Heinze, Hans-Jochen; Mulder, Gijsbertus

    1999-01-01

    EVENT-RELATED potentials (ERPs) were recorded as 12 subjects performed a delayed matching to sample task. We presented two bilateral abstract shapes and cued spatially which had to be memorized for a subsequent matching task: left, right or both. During memorization a posterior slow negative ERP

  15. Adapting to Changing Memory Retrieval Demands: Evidence from Event-Related Potentials

    Science.gov (United States)

    Benoit, Roland G.; Werkle-Bergner, Markus; Mecklinger, Axel; Kray, Jutta

    2009-01-01

    This study investigated preparatory processes involved in adapting to changing episodic memory retrieval demands. Event-related potentials (ERPs) were recorded while participants performed a general old/new recognition task and a specific task that also required retrieval of perceptual details. The relevant task remained either constant or changed…

  16. Attentional Mechanisms in Sports via Brain-Electrical Event-Related Potentials

    Science.gov (United States)

    Hack, Johannes; Memmert, Daniel; Rup, Andre

    2009-01-01

    In this study, we examined attention processes in complex, sport-specific decision-making tasks without interdependencies from anticipation. Psychophysiological and performance data recorded from advanced and intermediate level basketball referees were compared. Event-related potentials obtained while judging game situations in foul recognition…

  17. Complement Set Reference after Implicitly Small Quantities: An Event-Related Potentials Study

    Science.gov (United States)

    Ingram, Joanne; Ferguson, Heather J.

    2018-01-01

    An anaphoric reference to the complement-set is a reference to the set that does not fulfil the predicate of the preceding sentence. Preferred reference to the complement-set has been found in eye movements when a character's implicit desire for a high amount has been denied using a negative emotion. We recorded event-related potentials to examine…

  18. Temporal evolution of event-related desynchronization in acute stroke: A pilot study

    NARCIS (Netherlands)

    Tangwiriyasakul, Chayanin; Verhagen, Rens; Rutten, Wim; van Putten, Michel Johannes Antonius Maria

    2014-01-01

    Objective Assessment of event-related desynchronization (ERD) may assist in predicting recovery from stroke and rehabilitation, for instance in BCI applications. Here, we explore the temporal evolution of ERD during stroke recovery. Methods Ten stroke patients and eleven healthy controls were

  19. Conceptual Integration of Arithmetic Operations with Real-World Knowledge: Evidence from Event-Related Potentials

    Science.gov (United States)

    Guthormsen, Amy M.; Fisher, Kristie J.; Bassok, Miriam; Osterhout, Lee; DeWolf, Melissa; Holyoak, Keith J.

    2016-01-01

    Research on language processing has shown that the disruption of conceptual integration gives rise to specific patterns of event-related brain potentials (ERPs)--N400 and P600 effects. Here, we report similar ERP effects when adults performed cross-domain conceptual integration of analogous semantic and mathematical relations. In a problem-solving…

  20. Event-related potentials during visual selective attention in children of alcoholics.

    NARCIS (Netherlands)

    van der Stelt, O.; Gunning, W.B.; Snel, J.; Kok, A.

    1998-01-01

    Event-related potentials (ERPs) were recorded from 50 7-18 yr old children of alcoholics (COAs) and 50 age- and sex-matched control children while they performed a visual selective attention task. The task was to attend selectively to stimuli with a specified color (red or blue) in an attempt to

  1. MODULATION OF EVENT-RELATED POTENTIALS BY WORD REPETITION - THE ROLE OF VISUAL SELECTIVE ATTENTION

    NARCIS (Netherlands)

    OTTEN, LJ; RUGG, MD; DOYLE, MC

    1993-01-01

    Event-related potentials (ERPs) were recorded while subjects viewed visually presented words, some of which occurred twice. Each trial consisted of two colored letter strings, the requirement being to attend to and make a word/nonword discrimination for one of the strings. Attention was manipulated

  2. Declarative memory formation in hippocampal sclerosis: an intracranial event-related potentials study.

    NARCIS (Netherlands)

    Mormann, F.; Fernandez, G.S.E.; Klaver, P.; Weber, B.; Elger, C.E.; Fell, J.

    2007-01-01

    The functional deficits associated with hippocampal sclerosis during declarative memory formation are largely unknown. In this study, we analyzed intracranial event-related potentials recorded from the medial temporal lobes of nine epilepsy patients performing a word memorization task. We used

  3. Pitch Discrimination without Awareness in Congenital Amusia: Evidence from Event-Related Potentials

    Science.gov (United States)

    Moreau, Patricia; Jolicoeur, Pierre; Peretz, Isabelle

    2013-01-01

    Congenital amusia is a lifelong disorder characterized by a difficulty in perceiving and producing music despite normal intelligence and hearing. Behavioral data have indicated that it originates from a deficit in fine-grained pitch discrimination, and is expressed by the absence of a P3b event-related brain response for pitch differences smaller…

  4. Early referential context effects in sentence processing: Evidence from event-related brain potentials

    NARCIS (Netherlands)

    Berkum, J.J.A. van; Brown, C.M.; Hagoort, P.

    1999-01-01

    An event-related brain potentials experiment was carried out to examine the interplay of referential and structural factors during sentence processing in discourse. Subjects read (Dutch) sentences beginning like “David told the girl that … ” in short story contexts that had introduced either one or

  5. Event-related EEG changes preceding saccadic eye movements before and after dry immersion.

    Science.gov (United States)

    Tomilovskaya, E S; Kirenskaya, A V; Novototski-Vlasov, V Yu; Kozlovskaya, I B

    2004-07-01

    Objectives of this work were to quantify antisaccade characteristics, presaccadic slow negative EEG-potentials, and event-related EEG frequency band power (theta, alpha1, alpha2, beta1, beta2 and beta3) changes (ERD) in healthy volunteers before and after 6-day simulated weightlessness (dry immersion).

  6. Do U Txt? Event-Related Potentials to Semantic Anomalies in Standard and Texted English

    Science.gov (United States)

    Berger, Natalie I.; Coch, Donna

    2010-01-01

    Texted English is a hybrid, technology-based language derived from standard English modified to facilitate ease of communication via instant and text messaging. We compared semantic processing of texted and standard English sentences by recording event-related potentials in a classic semantic incongruity paradigm designed to elicit an N400 effect.…

  7. Temporal Dynamics of Late Second Language Acquisition: Evidence from Event-Related Brain Potentials

    Science.gov (United States)

    Steinhauer, Karsten; White, Erin J.; Drury, John E.

    2009-01-01

    The ways in which age of acquisition (AoA) may affect (morpho)syntax in second language acquisition (SLA) are discussed. We suggest that event-related brain potentials (ERPs) provide an appropriate online measure to test some such effects. ERP findings of the past decade are reviewed with a focus on recent and ongoing research. It is concluded…

  8. Implicit Phonological and Semantic Processing in Children with Developmental Dyslexia: Evidence from Event-Related Potentials

    Science.gov (United States)

    Jednorog, K.; Marchewka, A.; Tacikowski, P.; Grabowska, A.

    2010-01-01

    Dyslexia is characterized by a core phonological deficit, although recent studies indicate that semantic impairment also contributes to this condition. In this study, event-related potentials (ERP) were used to examine whether the N400 wave in dyslexic children is modulated by phonological or semantic priming, similarly to age-matched controls.…

  9. Scalp topography of event-related brain potentials and cognitive transitions during childhood.

    NARCIS (Netherlands)

    Molenaar, P.C.M.; van der Molen, M.W.; Stauder, J.E.A.

    1993-01-01

    Examined the relation between cognitive development (CGD) and the ontogenesis of event-related brain potentials (ERPs) during childhood among 48 girls (aged 5-7 yrs). The level of CGD was assessed with a standard Piagetian conservation kit. Ss performed a visual selective attention (oddball) task

  10. Brain activity and cognitive transition during childhood: A longitudinal event-related brain potential study.

    NARCIS (Netherlands)

    Stauder, J.E.A.; Molenaar, P.C.M.; van der Molen, M.W.

    1998-01-01

    Examined the relation between brain activation and cognitive development using event-related brain potentials (ERPs) and a longitudinal design. 5 yr old females performed a visual recognition ('oddball') task and an experimental analogue of the Piagetian conservation of liquid quantity task At three

  11. Representations in human visual short-term memory : an event-related brain potential study

    NARCIS (Netherlands)

    Klaver, P; Smid, HGOM; Heinze, HJ

    1999-01-01

    Behavioral measures and event-related potentials (ERPs) were recorded from 12 subjects while performing three delayed matching-to-sample tasks. The task instructions indicated whether stimulus locations, shapes or conjunctions of locations and shapes had to be memorized and matched against a probe.

  12. Effects of nicotine on visuo-spatial selective attention as indexed by event-related potentials.

    Science.gov (United States)

    Meinke, A; Thiel, C M; Fink, G R

    2006-08-11

    Nicotine has been shown to specifically reduce reaction times to invalidly cued targets in spatial cueing paradigms. In two experiments, we used event-related potentials to test whether the facilitative effect of nicotine upon the detection of invalidly cued targets is due to a modulation of perceptual processing, as indexed by early attention-related event-related potential components. Furthermore, we assessed whether the effect of nicotine on such unattended stimuli depends upon the use of exogenous or endogenous cues. In both experiments, the electroencephalogram was recorded while non-smokers completed discrimination tasks in Posner-type paradigms after chewing a nicotine polacrilex gum (Nicorette 2 mg) in one session and a placebo gum in another session. Nicotine reduced reaction times to invalidly cued targets when cueing was endogenous. In contrast, no differential effect of nicotine on reaction times was observed when exogenous cues were used. Electrophysiologically, we found a similar attentional modulation of the P1 and N1 components under placebo and nicotine but a differential modulation of later event-related potential components at a frontocentral site. The lack of a drug-dependent modulation of P1 and N1 in the presence of a behavioral effect suggests that the effect of nicotine in endogenous visuo-spatial cueing tasks is not due to an alteration of perceptual processes. Rather, the differential modulation of frontocentral event-related potentials suggests that nicotine acts at later stages of target processing.

  13. Contingent Attentional Capture by Top-Down Control Settings: Converging Evidence from Event-Related Potentials

    Science.gov (United States)

    Lien, Mei-Ching; Ruthruff, Eric; Goodin, Zachary; Remington, Roger W.

    2008-01-01

    Theories of attentional control are divided over whether the capture of spatial attention depends primarily on stimulus salience or is contingent on attentional control settings induced by task demands. The authors addressed this issue using the N2-posterior-contralateral (N2pc) effect, a component of the event-related brain potential thought to…

  14. Semantic ambiguity processing in sentence context: Evidence from event-related fMRI

    NARCIS (Netherlands)

    Zempleni, Monika-Zita; Renken, Remco; Hoeks, John C. J.; Hoogduin, Johannes M.; Stowe, Laurie A.

    2007-01-01

    Lexical semantic ambiguity is the phenomenon when a word has multiple meanings (e.g. 'bank'). The aim of this event-related functional MRI study was to identify those brain areas, which are involved in contextually driven ambiguity resolution. Ambiguous words were selected which have a most

  15. Working memory processes show different degrees of lateralization : Evidence from event-related potentials

    NARCIS (Netherlands)

    Talsma, D; Wijers, A.A.; Klaver, P; Mulder, G.

    This study aimed to identify different processes in working memory, using event-related potentials (ERPs) and response times. Abstract polygons were presented for memorization and subsequent recall in a delayed matching-to-sample paradigm. Two polygons were presented bilaterally for memorization and

  16. Changes in event-related potential functional networks predict traumatic brain injury in piglets.

    Science.gov (United States)

    Atlan, Lorre S; Lan, Ingrid S; Smith, Colin; Margulies, Susan S

    2018-06-01

    Traumatic brain injury is a leading cause of cognitive and behavioral deficits in children in the US each year. None of the current diagnostic tools, such as quantitative cognitive and balance tests, have been validated to identify mild traumatic brain injury in infants, adults and animals. In this preliminary study, we report a novel, quantitative tool that has the potential to quickly and reliably diagnose traumatic brain injury and which can track the state of the brain during recovery across multiple ages and species. Using 32 scalp electrodes, we recorded involuntary auditory event-related potentials from 22 awake four-week-old piglets one day before and one, four, and seven days after two different injury types (diffuse and focal) or sham. From these recordings, we generated event-related potential functional networks and assessed whether the patterns of the observed changes in these networks could distinguish brain-injured piglets from non-injured. Piglet brains exhibited significant changes after injury, as evaluated by five network metrics. The injury prediction algorithm developed from our analysis of the changes in the event-related potentials functional networks ultimately produced a tool with 82% predictive accuracy. This novel approach is the first application of auditory event-related potential functional networks to the prediction of traumatic brain injury. The resulting tool is a robust, objective and predictive method that offers promise for detecting mild traumatic brain injury, in particular because collecting event-related potentials data is noninvasive and inexpensive. Copyright © 2018 The Authors. Published by Elsevier Ltd.. All rights reserved.

  17. The Recording and Quantification of Event-Related Potentials: II. Signal Processing and Analysis

    Directory of Open Access Journals (Sweden)

    Paniz Tavakoli

    2015-06-01

    Full Text Available Event-related potentials are an informative method for measuring the extent of information processing in the brain. The voltage deflections in an ERP waveform reflect the processing of sensory information as well as higher-level processing that involves selective attention, memory, semantic comprehension, and other types of cognitive activity. ERPs provide a non-invasive method of studying, with exceptional temporal resolution, cognitive processes in the human brain. ERPs are extracted from scalp-recorded electroencephalography by a series of signal processing steps. The present tutorial will highlight several of the analysis techniques required to obtain event-related potentials. Some methodological issues that may be encountered will also be discussed.

  18. Report order and identification of multidimensional stimuli: a study of event-related brain potentials.

    Science.gov (United States)

    Shieh, Kong-King; Shen, I-Hsuan

    2004-06-01

    An experiment was conducted to investigate the effect of order of report on multidimensional stimulus identification. Subjects were required to identify each two-dimensional symbol by pushing corresponding buttons on the keypad on which there were two columns representing the two dimensions. Order of report was manipulated for the dimension represented by the left or right column. Both behavioral data and event-related potentials were recorded from 14 college students. Behavioral data analysis showed that order of report had a significant effect on response times. Such results were consistent with those of previous studies. Analysis of event-related brain potentials showed significant differences in peak amplitude and mean amplitude at time windows of 120-250 msec. at Fz, F3, and F4 and of 350-750 msec. at Fz, F3, F4, Cz, and Pz. Data provided neurophysiological evidence that reporting dimensional values according to natural language habits was appropriate and less cognitively demanding.

  19. Glucose enhancement of event-related potentials associated with episodic memory and attention

    OpenAIRE

    Brown, Louise; Riby, Leigh

    2013-01-01

    Previous studies have reported that increasing glycaemia by a glucose-containing drink enhances memory functioning. The aim of the present study was to extend this literature by examining the effects of glucose on episodic memory as well as attention processes, and to investigate associated event-related potential (ERP) markers. Fifteen minutes after treatment (25 g glucose or placebo drink), 35 participants performed an old/new recognition memory task and a Stroop colour naming task. Consist...

  20. MEG event-related desynchronization and synchronization deficits during basic somatosensory processing in individuals with ADHD

    Directory of Open Access Journals (Sweden)

    Wang Frank

    2008-02-01

    Full Text Available Abstract Background Attention-Deficit/Hyperactivity Disorder (ADHD is a prevalent, complex disorder which is characterized by symptoms of inattention, hyperactivity, and impulsivity. Convergent evidence from neurobiological studies of ADHD identifies dysfunction in fronto-striatal-cerebellar circuitry as the source of behavioural deficits. Recent studies have shown that regions governing basic sensory processing, such as the somatosensory cortex, show abnormalities in those with ADHD suggesting that these processes may also be compromised. Methods We used event-related magnetoencephalography (MEG to examine patterns of cortical rhythms in the primary (SI and secondary (SII somatosensory cortices in response to median nerve stimulation, in 9 adults with ADHD and 10 healthy controls. Stimuli were brief (0.2 ms non-painful electrical pulses presented to the median nerve in two counterbalanced conditions: unpredictable and predictable stimulus presentation. We measured changes in strength, synchronicity, and frequency of cortical rhythms. Results Healthy comparison group showed strong event-related desynchrony and synchrony in SI and SII. By contrast, those with ADHD showed significantly weaker event-related desynchrony and event-related synchrony in the alpha (8–12 Hz and beta (15–30 Hz bands, respectively. This was most striking during random presentation of median nerve stimulation. Adults with ADHD showed significantly shorter duration of beta rebound in both SI and SII except for when the onset of the stimulus event could be predicted. In this case, the rhythmicity of SI (but not SII in the ADHD group did not differ from that of controls. Conclusion Our findings suggest that somatosensory processing is altered in individuals with ADHD. MEG constitutes a promising approach to profiling patterns of neural activity during the processing of sensory input (e.g., detection of a tactile stimulus, stimulus predictability and facilitating our

  1. The origin and nature of categorical perception of colour: Evidence from event-related brain potentials.

    OpenAIRE

    Clifford, Alexandra.

    2009-01-01

    Categorical perception (CP) of colour is demonstrated by faster or more accurate discrimination of colours that cross a category boundary, compared to equivalently spaced colours from the same colour category. Despite a plethora of behavioural research exploring the origin and nature of colour CP, the processes involved in the effect are still unresolved. This thesis investigates the time course and underlying mechanisms of colour CP by using the Event-Related Potential (ERP) technique. This ...

  2. An Event-related Brain Potential Study of English Morphosyntactic Processing in Japanese Learners of English

    OpenAIRE

    Tatsuta, Natsuko

    2014-01-01

    This dissertation investigated the neural mechanisms underlying English morphosyntactic processing in Case, subject-verb agreement, and past tense inflection in Japanese learners of English (JLEs) using event-related brain potentials (ERPs) in terms of the effects of the age of second language (L2) acquisition (the age of learning English), L2 proficiency level (the English proficiency level), and native/first language (L1) transfer. Researchers have debated for a number of years the question...

  3. Abnormal occipital event-related potentials in Parkinson's disease with concomitant REM sleep behavior disorder.

    Science.gov (United States)

    Gaudreault, Pierre-Olivier; Gagnon, Jean-François; Montplaisir, Jacques; Vendette, Mélanie; Postuma, Ronald B; Gagnon, Katia; Gosselin, Nadia

    2013-02-01

    Rapid eye movement sleep behavior disorder is found in 33-46% of patients with Parkinson's disease and was shown to be associated with cognitive deficits. Our goal was to improve our understanding of the role of this sleep disorder in cerebral dysfunction occurring in Parkinson's disease using a visual cognitive task and event-related potentials. Sixteen patients with Parkinson's disease and rapid eye movement sleep behavior disorder, 15 patients with Parkinson's disease without rapid eye movement sleep behavior disorder and 16 healthy control subjects were included. The amplitude and latency of event-related potentials were compared between groups. No group differences were found for reaction times or accuracy. A Group effect was found for P2 wave amplitude; patients with rapid eye movement sleep behavior disorder had increased P2 in comparison with the control group (p disorder were associated with abnormal visual P2 component of event-related potentials. Although patients with Parkinson's disease alone were not significantly different from patients with combined Parkinson's disease and rapid eye movement sleep behavior disorder, their P2 amplitudes were not sufficiently abnormal to differ from that of control subjects. This study confirms that rapid eye movement sleep behavior disorder accentuates cerebral dysfunctions in Parkinson's disease. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Hologlyphics: volumetric image synthesis performance system

    Science.gov (United States)

    Funk, Walter

    2008-02-01

    This paper describes a novel volumetric image synthesis system and artistic technique, which generate moving volumetric images in real-time, integrated with music. The system, called the Hologlyphic Funkalizer, is performance based, wherein the images and sound are controlled by a live performer, for the purposes of entertaining a live audience and creating a performance art form unique to volumetric and autostereoscopic images. While currently configured for a specific parallax barrier display, the Hologlyphic Funkalizer's architecture is completely adaptable to various volumetric and autostereoscopic display technologies. Sound is distributed through a multi-channel audio system; currently a quadraphonic speaker setup is implemented. The system controls volumetric image synthesis, production of music and spatial sound via acoustic analysis and human gestural control, using a dedicated control panel, motion sensors, and multiple musical keyboards. Music can be produced by external acoustic instruments, pre-recorded sounds or custom audio synthesis integrated with the volumetric image synthesis. Aspects of the sound can control the evolution of images and visa versa. Sounds can be associated and interact with images, for example voice synthesis can be combined with an animated volumetric mouth, where nuances of generated speech modulate the mouth's expressiveness. Different images can be sent to up to 4 separate displays. The system applies many novel volumetric special effects, and extends several film and video special effects into the volumetric realm. Extensive and various content has been developed and shown to live audiences by a live performer. Real world applications will be explored, with feedback on the human factors.

  5. Volumetric velocimetry for fluid flows

    Science.gov (United States)

    Discetti, Stefano; Coletti, Filippo

    2018-04-01

    In recent years, several techniques have been introduced that are capable of extracting 3D three-component velocity fields in fluid flows. Fast-paced developments in both hardware and processing algorithms have generated a diverse set of methods, with a growing range of applications in flow diagnostics. This has been further enriched by the increasingly marked trend of hybridization, in which the differences between techniques are fading. In this review, we carry out a survey of the prominent methods, including optical techniques and approaches based on medical imaging. An overview of each is given with an example of an application from the literature, while focusing on their respective strengths and challenges. A framework for the evaluation of velocimetry performance in terms of dynamic spatial range is discussed, along with technological trends and emerging strategies to exploit 3D data. While critical challenges still exist, these observations highlight how volumetric techniques are transforming experimental fluid mechanics, and that the possibilities they offer have just begun to be explored.

  6. Volumetric Visualization of Human Skin

    Science.gov (United States)

    Kawai, Toshiyuki; Kurioka, Yoshihiro

    We propose a modeling and rendering technique of human skin, which can provide realistic color, gloss and translucency for various applications in computer graphics. Our method is based on volumetric representation of the structure inside of the skin. Our model consists of the stratum corneum and three layers of pigments. The stratum corneum has also layered structure in which the incident light is reflected, refracted and diffused. Each layer of pigment has carotene, melanin or hemoglobin. The density distributions of pigments which define the color of each layer can be supplied as one of the voxel values. Surface normals of upper-side voxels are fluctuated to produce bumps and lines on the skin. We apply ray tracing approach to this model to obtain the rendered image. Multiple scattering in the stratum corneum, reflective and absorptive spectrum of pigments are considered. We also consider Fresnel term to calculate the specular component for glossy surface of skin. Some examples of rendered images are shown, which can successfully visualize a human skin.

  7. Event-related theta synchronization predicts deficit in facial affect recognition in schizophrenia.

    Science.gov (United States)

    Csukly, Gábor; Stefanics, Gábor; Komlósi, Sarolta; Czigler, István; Czobor, Pál

    2014-02-01

    Growing evidence suggests that abnormalities in the synchronized oscillatory activity of neurons in schizophrenia may lead to impaired neural activation and temporal coding and thus lead to neurocognitive dysfunctions, such as deficits in facial affect recognition. To gain an insight into the neurobiological processes linked to facial affect recognition, we investigated both induced and evoked oscillatory activity by calculating the Event Related Spectral Perturbation (ERSP) and the Inter Trial Coherence (ITC) during facial affect recognition. Fearful and neutral faces as well as nonface patches were presented to 24 patients with schizophrenia and 24 matched healthy controls while EEG was recorded. The participants' task was to recognize facial expressions. Because previous findings with healthy controls showed that facial feature decoding was associated primarily with oscillatory activity in the theta band, we analyzed ERSP and ITC in this frequency band in the time interval of 140-200 ms, which corresponds to the N170 component. Event-related theta activity and phase-locking to facial expressions, but not to nonface patches, predicted emotion recognition performance in both controls and patients. Event-related changes in theta amplitude and phase-locking were found to be significantly weaker in patients compared with healthy controls, which is in line with previous investigations showing decreased neural synchronization in the low frequency bands in patients with schizophrenia. Neural synchrony is thought to underlie distributed information processing. Our results indicate a less effective functioning in the recognition process of facial features, which may contribute to a less effective social cognition in schizophrenia. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  8. Effects of hypnagogic imagery on the event-related potential to external tone stimuli.

    Science.gov (United States)

    Michida, Nanae; Hayashi, Mitsuo; Hori, Tadao

    2005-07-01

    The purpose of this study was to examine the influence of hypnagogic imagery on the information processes of external tone stimuli during the sleep onset period with the use of event-related potentials. Event-related potentials to tone stimuli were compared between conditions with and without the experience of hypnagogic imagery. To control the arousal level when the tone was presented, a certain criterion named the electroencephalogram stage was used. Stimuli were presented at electroencephalogram stage 4, which was characterized by the appearance of a vertex sharp wave. Data were collected in the sleep laboratory at Hiroshima University. Eleven healthy university and graduate school students participated in the study. N/A. Experiments were performed at night. Reaction times to tone stimuli were measured, and only trials with shorter reaction times than 5000 milliseconds were analyzed. Electroencephalograms were recorded from Fz, Cz, Pz, Oz, T5 and T6. There were no differences in reaction times and electroencephalogram spectra between the conditions of with and without hypnagogic imagery. These results indicated that the arousal levels were not different between the 2 conditions. On the other hand, the N550 amplitude of the event-related potentials in the imagery condition was lower than in the no-imagery condition. The decrease in the N550 amplitude in the imagery condition showed that experiences of hypnagogic imagery exert some influence on the information processes of external tone stimuli. It is possible that the processing of hypnagogic imagery interferes with the processing of external stimuli, lowering the sensitivity to external stimuli.

  9. Acute low-level alcohol consumption reduces phase locking of event-related oscillations in rodents.

    Science.gov (United States)

    Amodeo, Leslie R; Wills, Derek N; Ehlers, Cindy L

    2017-07-14

    Event-related oscillations (EROs) are rhythmic changes that are evoked by a sensory and/or cognitive stimulus that can influence the dynamics of the EEG. EROs are defined by the decomposition of the EEG signal into magnitude (energy) and phase information and can be elicited in both humans and animals. EROs have been linked to several relevant genes associated with ethanol dependence phenotypes in humans and are altered in selectively bred alcohol-preferring rats. However, pharmacological studies are only beginning to emerge investigating the impact low intoxicating doses of ethanol can have on event-related neural oscillations. The main goal of this study was to investigate the effects of low levels of voluntary consumption of ethanol, in rats, on phase locking of EROs in order to give further insight into the acute intoxicating effects of ethanol on the brain. To this end, we allow rats to self-administer unsweetened 20% ethanol over 15 intermittent sessions. This method results in a stable low-dose consumption of ethanol. Using an auditory event-related potential "oddball" paradigm, we investigated the effects of alcohol on the phase variability of EROs from electrodes implanted into the frontal cortex, dorsal hippocampus, and amygdala. We found that intermittent ethanol self-administration was sufficient to produce a significant reduction in overall intraregional synchrony across all targeted regions. These data suggest that phase locking of EROs within brain regions known to be impacted by alcohol may represent a sensitive biomarker of low levels of alcohol intoxication. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Event-related potentials reveal increased distraction by salient global objects in older adults

    DEFF Research Database (Denmark)

    Wiegand, Iris; Finke, Kathrin; Töllner, Thomas

    Age-related changes in visual functions influence how older individuals perceive and react upon objects in their environment. In particular, older individuals might be more distracted by highly salient, irrelevant information. Kanizsa figures induce a ‘global precedence’ effect, which reflects...... a processing advantage for salient whole-object representations relative to configurations of local elements not inducing a global form. We investigated event-related potential (ERP) correlates of age-related decline in visual abilities, and specifically, distractibility by salient global objects in visual...

  11. [Progress on neuropsychology and event-related potentials in patients with brain trauma].

    Science.gov (United States)

    Dong, Ri-xia; Cai, Wei-xiong; Tang, Tao; Huang, Fu-yin

    2010-02-01

    With the development of information technology, as one of the research frontiers in neurophysiology, event-related potentials (ERP) is concerned increasingly by international scholars, which provides a feasible and objective method for exploring cognitive function. There are many advances in neuropsychology due to new assessment tool for the last years. The basic theories in the field of ERP and neuropsychology were reviewed in this article. The research and development in evaluating cognitive function of patients with syndrome after brain trauma were focused in this review, and the perspectives for the future research of ERP was also explored.

  12. The light-makeup advantage in facial processing: Evidence from event-related potentials

    OpenAIRE

    Tagai, Keiko; Shimakura, Hitomi; Isobe, Hiroko; Nittono, Hiroshi

    2017-01-01

    The effects of makeup on attractiveness have been evaluated using mainly subjective measures. In this study, event-related brain potentials (ERPs) were recorded from a total of 45 Japanese women (n = 23 and n = 22 for Experiment 1 and 2, respectively) to examine the neural processing of faces with no makeup, light makeup, and heavy makeup. To have the participants look at each face carefully, an identity judgement task was used: they were asked to judge whether the two faces presented in succ...

  13. Cognitive event-related potentials in comatose and post-comatose states.

    Science.gov (United States)

    Vanhaudenhuyse, Audrey; Laureys, Steven; Perrin, Fabien

    2008-01-01

    We review the interest of cognitive event-related potentials (ERPs) in comatose, vegetative, or minimally conscious patients. Auditory cognitive ERPs are useful to investigate residual cognitive functions, such as echoic memory (MMN), acoustical and semantic discrimination (P300), and incongruent language detection (N400). While early ERPs (such as the absence of cortical responses on somatosensory-evoked potentials) predict bad outcome, cognitive ERPs (MMN and P300) are indicative of recovery of consciousness. In coma-survivors, cognitive potentials are more frequently obtained when using stimuli that are more ecologic or have an emotional content (such as the patient's own name) than when using classical sine tones.

  14. Stereotype activation is unintentional: Behavioural and event-related potenials evidence.

    Science.gov (United States)

    Wang, Pei; Yang, Ya-Ping; Tan, Chen-Hao; Zhao, Xiang-Xia; Liu, Yong-He; Lin, Chong-De

    2016-04-01

    In this study, a priming Stroop paradigm was used to determine whether stereotype activation is unintentional. Priming conditions (priming/no-priming) and the relationship between priming and target (consistent/inconsistent/no-relation) were the independent variables; accuracy, reaction time and N400 amplitude were used as dependent variables. The reaction time revealed that stereotype activation is, to some extent, unintentional. Furthermore, the event-related potenial (ERP) results showed that N400 amplitude was larger for inconsistent conditions than for consistent conditions. This result supported the notion that stereotype activation is an unintentional and automatic process. © 2015 International Union of Psychological Science.

  15. Changing relations between intelligence and brain activity in late childhood: A longitudinal event-related potential study.

    NARCIS (Netherlands)

    Stauder, J.E.A.; van der Molen, M.W.; Molenaar, P.C.M.

    1998-01-01

    In studying the relationship between Raven intelligence and event-related brain potentials to a visual oddball task in the same children, at respectively 9, 10 and 11 years of age, dramatic changes were observed with age. The event-related amplitude data suggest a shift in relation between

  16. Effects of white noise on event-related potentials in somatosensory Go/No-go paradigms.

    Science.gov (United States)

    Ohbayashi, Wakana; Kakigi, Ryusuke; Nakata, Hiroki

    2017-09-06

    Exposure to auditory white noise has been shown to facilitate human cognitive function. This phenomenon is termed stochastic resonance, and a moderate amount of auditory noise has been suggested to benefit individuals in hypodopaminergic states. The present study investigated the effects of white noise on the N140 and P300 components of event-related potentials in somatosensory Go/No-go paradigms. A Go or No-go stimulus was presented to the second or fifth digit of the left hand, respectively, at the same probability. Participants performed somatosensory Go/No-go paradigms while hearing three different white noise levels (45, 55, and 65 dB conditions). The peak amplitudes of Go-P300 and No-go-P300 in ERP waveforms were significantly larger under 55 dB than 45 and 65 dB conditions. White noise did not affect the peak latency of N140 or P300, or the peak amplitude of N140. Behavioral data for the reaction time, SD of reaction time, and error rates showed the absence of an effect by white noise. This is the first event-related potential study to show that exposure to auditory white noise at 55 dB enhanced the amplitude of P300 during Go/No-go paradigms, reflecting changes in the neural activation of response execution and inhibition processing.

  17. Sad facial cues inhibit temporal attention: evidence from an event-related potential study.

    Science.gov (United States)

    Kong, Xianxian; Chen, Xiaoqiang; Tan, Bo; Zhao, Dandan; Jin, Zhenlan; Li, Ling

    2013-06-19

    We examined the influence of different emotional cues (happy or sad) on temporal attention (short or long interval) using behavioral as well as event-related potential recordings during a Stroop task. Emotional stimuli cued short and long time intervals, inducing 'sad-short', 'sad-long', 'happy-short', and 'happy-long' conditions. Following the intervals, participants performed a numeric Stroop task. Behavioral results showed the temporal attention effects in the sad-long, happy-long, and happy-short conditions, in which valid cues quickened the reaction times, but not in the sad-short condition. N2 event-related potential components showed sad cues to have decreased activity for short intervals compared with long intervals, whereas happy cues did not. Taken together, these findings provide evidence for different modulation of sad and happy facial cues on temporal attention. Furthermore, sad cues inhibit temporal attention, resulting in longer reaction time and decreased neural activity in the short interval by diverting more attentional resources.

  18. Tactile event-related potentials in amyotrophic lateral sclerosis (ALS): Implications for brain-computer interface.

    Science.gov (United States)

    Silvoni, S; Konicar, L; Prats-Sedano, M A; Garcia-Cossio, E; Genna, C; Volpato, C; Cavinato, M; Paggiaro, A; Veser, S; De Massari, D; Birbaumer, N

    2016-01-01

    We investigated neurophysiological brain responses elicited by a tactile event-related potential paradigm in a sample of ALS patients. Underlying cognitive processes and neurophysiological signatures for brain-computer interface (BCI) are addressed. We stimulated the palm of the hand in a group of fourteen ALS patients and a control group of ten healthy participants and recorded electroencephalographic signals in eyes-closed condition. Target and non-target brain responses were analyzed and classified offline. Classification errors served as the basis for neurophysiological brain response sub-grouping. A combined behavioral and quantitative neurophysiological analysis of sub-grouped data showed neither significant between-group differences, nor significant correlations between classification performance and the ALS patients' clinical state. Taking sequential effects of stimuli presentation into account, analyses revealed mean classification errors of 19.4% and 24.3% in healthy participants and ALS patients respectively. Neurophysiological correlates of tactile stimuli presentation are not altered by ALS. Tactile event-related potentials can be used to monitor attention level and task performance in ALS and may constitute a viable basis for future BCIs. Implications for brain-computer interface implementation of the proposed method for patients in critical conditions, such as the late stage of ALS and the (completely) locked-in state, are discussed. Copyright © 2015 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  19. Event-related delta, theta, alpha and gamma correlates to auditory oddball processing during Vipassana meditation

    Science.gov (United States)

    Delorme, Arnaud; Polich, John

    2013-01-01

    Long-term Vipassana meditators sat in meditation vs. a control (instructed mind wandering) states for 25 min, electroencephalography (EEG) was recorded and condition order counterbalanced. For the last 4 min, a three-stimulus auditory oddball series was presented during both meditation and control periods through headphones and no task imposed. Time-frequency analysis demonstrated that meditation relative to the control condition evinced decreased evoked delta (2–4 Hz) power to distracter stimuli concomitantly with a greater event-related reduction of late (500–900 ms) alpha-1 (8–10 Hz) activity, which indexed altered dynamics of attentional engagement to distracters. Additionally, standard stimuli were associated with increased early event-related alpha phase synchrony (inter-trial coherence) and evoked theta (4–8 Hz) phase synchrony, suggesting enhanced processing of the habituated standard background stimuli. Finally, during meditation, there was a greater differential early-evoked gamma power to the different stimulus classes. Correlation analysis indicated that this effect stemmed from a meditation state-related increase in early distracter-evoked gamma power and phase synchrony specific to longer-term expert practitioners. The findings suggest that Vipassana meditation evokes a brain state of enhanced perceptual clarity and decreased automated reactivity. PMID:22648958

  20. Event-related potentials during visual selective attention in children of alcoholics.

    Science.gov (United States)

    van der Stelt, O; Gunning, W B; Snel, J; Kok, A

    1998-12-01

    Event-related potentials were recorded from 7- to 18-year-old children of alcoholics (COAs, n = 50) and age- and sex-matched control children (n = 50) while they performed a visual selective attention task. The task was to attend selectively to stimuli with a specified color (red or blue) in an attempt to detect the occurrence of target stimuli. COAs manifested a smaller P3b amplitude to attended-target stimuli over the parietal and occipital scalp than did the controls. A more specific analysis indicated that both the attentional relevance and the target properties of the eliciting stimulus determined the observed P3b amplitude differences between COAs and controls. In contrast, no significant group differences were observed in attention-related earlier occurring event-related potential components, referred to as frontal selection positivity, selection negativity, and N2b. These results represent neurophysiological evidence that COAs suffer from deficits at a late (semantic) level of visual selective information processing that are unlikely a consequence of deficits at earlier (sensory) levels of selective processing. The findings support the notion that a reduced visual P3b amplitude in COAs represents a high-level processing dysfunction indicating their increased vulnerability to alcoholism.

  1. Source Space Analysis of Event-Related Dynamic Reorganization of Brain Networks

    Directory of Open Access Journals (Sweden)

    Andreas A. Ioannides

    2012-01-01

    Full Text Available How the brain works is nowadays synonymous with how different parts of the brain work together and the derivation of mathematical descriptions for the functional connectivity patterns that can be objectively derived from data of different neuroimaging techniques. In most cases static networks are studied, often relying on resting state recordings. Here, we present a quantitative study of dynamic reconfiguration of connectivity for event-related experiments. Our motivation is the development of a methodology that can be used for personalized monitoring of brain activity. In line with this motivation, we use data with visual stimuli from a typical subject that participated in different experiments that were previously analyzed with traditional methods. The earlier studies identified well-defined changes in specific brain areas at specific latencies related to attention, properties of stimuli, and tasks demands. Using a recently introduced methodology, we track the event-related changes in network organization, at source space level, thus providing a more global and complete view of the stages of processing associated with the regional changes in activity. The results suggest the time evolving modularity as an additional brain code that is accessible with noninvasive means and hence available for personalized monitoring and clinical applications.

  2. Source space analysis of event-related dynamic reorganization of brain networks.

    Science.gov (United States)

    Ioannides, Andreas A; Dimitriadis, Stavros I; Saridis, George A; Voultsidou, Marotesa; Poghosyan, Vahe; Liu, Lichan; Laskaris, Nikolaos A

    2012-01-01

    How the brain works is nowadays synonymous with how different parts of the brain work together and the derivation of mathematical descriptions for the functional connectivity patterns that can be objectively derived from data of different neuroimaging techniques. In most cases static networks are studied, often relying on resting state recordings. Here, we present a quantitative study of dynamic reconfiguration of connectivity for event-related experiments. Our motivation is the development of a methodology that can be used for personalized monitoring of brain activity. In line with this motivation, we use data with visual stimuli from a typical subject that participated in different experiments that were previously analyzed with traditional methods. The earlier studies identified well-defined changes in specific brain areas at specific latencies related to attention, properties of stimuli, and tasks demands. Using a recently introduced methodology, we track the event-related changes in network organization, at source space level, thus providing a more global and complete view of the stages of processing associated with the regional changes in activity. The results suggest the time evolving modularity as an additional brain code that is accessible with noninvasive means and hence available for personalized monitoring and clinical applications.

  3. Statistical language learning in neonates revealed by event-related brain potentials

    Directory of Open Access Journals (Sweden)

    Näätänen Risto

    2009-03-01

    Full Text Available Abstract Background Statistical learning is a candidate for one of the basic prerequisites underlying the expeditious acquisition of spoken language. Infants from 8 months of age exhibit this form of learning to segment fluent speech into distinct words. To test the statistical learning skills at birth, we recorded event-related brain responses of sleeping neonates while they were listening to a stream of syllables containing statistical cues to word boundaries. Results We found evidence that sleeping neonates are able to automatically extract statistical properties of the speech input and thus detect the word boundaries in a continuous stream of syllables containing no morphological cues. Syllable-specific event-related brain responses found in two separate studies demonstrated that the neonatal brain treated the syllables differently according to their position within pseudowords. Conclusion These results demonstrate that neonates can efficiently learn transitional probabilities or frequencies of co-occurrence between different syllables, enabling them to detect word boundaries and in this way isolate single words out of fluent natural speech. The ability to adopt statistical structures from speech may play a fundamental role as one of the earliest prerequisites of language acquisition.

  4. Emotional Granularity Effects on Event-Related Brain Potentials during Affective Picture Processing.

    Science.gov (United States)

    Lee, Ja Y; Lindquist, Kristen A; Nam, Chang S

    2017-01-01

    There is debate about whether emotional granularity , the tendency to label emotions in a nuanced and specific manner, is merely a product of labeling abilities, or a systematic difference in the experience of emotion during emotionally evocative events. According to the Conceptual Act Theory of Emotion (CAT) (Barrett, 2006), emotional granularity is due to the latter and is a product of on-going temporal differences in how individuals categorize and thus make meaning of their affective states. To address this question, the present study investigated the effects of individual differences in emotional granularity on electroencephalography-based brain activity during the experience of emotion in response to affective images. Event-related potentials (ERP) and event-related desynchronization and synchronization (ERD/ERS) analysis techniques were used. We found that ERP responses during the very early (60-90 ms), middle (270-300 ms), and later (540-570 ms) moments of stimulus presentation were associated with individuals' level of granularity. We also observed that highly granular individuals, compared to lowly granular individuals, exhibited relatively stable desynchronization of alpha power (8-12 Hz) and synchronization of gamma power (30-50 Hz) during the 3 s of stimulus presentation. Overall, our results suggest that emotional granularity is related to differences in neural processing throughout emotional experiences and that high granularity could be associated with access to executive control resources and a more habitual processing of affective stimuli, or a kind of "emotional complexity." Implications for models of emotion are also discussed.

  5. Influence of negative emotion on the framing effect: evidence from event-related potentials.

    Science.gov (United States)

    Ma, Qingguo; Pei, Guanxiong; Wang, Kai

    2015-04-15

    The framing effect is the phenomenon in which different descriptions of an identical problem can result in different choices. The influence of negative emotions on the framing effect and its neurocognitive basis are important issues, especially in the domain of saving lives, which is essential and highly risky. In each trial of our experiment, the emotion stimulus is presented to the participants, followed by the decision-making stimulus, which comprises certain and risky options with the same expected value. Each pair of options is positively or negatively framed. The behavioral results indicate a significant interactive effect between negative emotion and frame; thus, the risk preference under the positive frame can be enhanced by negative emotions, whereas this finding is not true under the negative frame. The event-related potential analysis indicates that choosing certain options under the positive frame with negative emotion priming generates smaller P2 and P3 amplitudes and a larger N2 amplitude than with neutral emotion priming. The event-related potential findings indicate that individuals can detect risk faster and experience more conflict and increased decision difficulty if they choose certain options under the positive frame with negative priming compared with neutral priming.

  6. Lateralization of event-related potential effects during mental rotation of polygons.

    Science.gov (United States)

    Pellkofer, Julia; Jansen, Petra; Heil, Martin

    2012-07-11

    Numerous studies have shown that there is an amplitude modulation of the late positivity depending on the angular disparity during mental rotation performance. However, almost all of these studies used characters as stimulus material, whereas studies with different stimuli are rare. In the present experiment, 35 participants were instructed to rotate polygons mentally. Most importantly, with this stimulus material, the well-known event-related potential effects were also present at posterior electrode leads. Interestingly, the amplitude modulation were found to be larger and more reliable over left than over right posterior electrode leads, a finding reported previously for characters as stimuli, although not consistently. Thus, the present data suggest that the left lateralization of event-related potential effects during mental rotation of characters might not be because of their 'verbal nature', but might suggest a stronger involvement of the left parietal cortex during mental rotation per se, a suggestion that needs to be addressed with methods providing a higher spatial resolution.

  7. The impacts of racial group membership on people's distributive justice: an event-related potential study.

    Science.gov (United States)

    Wang, Yan; Tang, Yi-Yuan; Deng, Yuqin

    2014-04-16

    How individuals and societies distribute benefits has long been studied by psychologists and sociologists. Previous work has highlighted the importance of social identity on people's justice concerns. However, it is not entirely clear how racial in-group/out-group relationship affects the brain activity in distributive justice. In this study, event-related potentials were recorded while participants made their decisions about donation allocation. Behavioral results showed that racial in-group factor affected participants' decisions on justice consideration. Participants were more likely to make relatively equity decisions when racial in-group factor was congruent with equity compared with the corresponding incongruent condition. Moreover, this incongruent condition took longer response times than congruent condition. Meanwhile, less equity decisions were made when efficiency was larger in the opposite side to equity than it was equal between the two options. Scalp event-related potential analyses revealed that greater P300 and late positive potential amplitudes were elicited by the incongruent condition compared with the congruent condition. These findings suggest that the decision-making of distributive justice could be modulated by racial group membership, and greater attentional resources or cognitive efforts are required when racial in-group factor and equity conflict with each other.

  8. Event-related frontal alpha asymmetries: electrophysiological correlates of approach motivation.

    Science.gov (United States)

    Schöne, Benjamin; Schomberg, Jessica; Gruber, Thomas; Quirin, Markus

    2016-02-01

    Over the last decades, frontal alpha asymmetries observed during resting state periods of several minutes have been used as a marker of affective-motivational states. To date, there is no evidence that alpha asymmetries can be observed in response to brief affective-motivational stimuli, as typically presented in event-related designs. As we argue, frontal alpha asymmetry might indeed be elicited by brief events if they are salient enough. In an event-related design, we used erotic pictures, i.e., highly salient incentives to elicit approach motivation, and contrasted them with pictures of dressed attractive women. As expected, we found significant alpha asymmetries for erotic pictures as compared to control pictures. Our findings suggest that the highly reactive reward system can lead to immediate, phasic changes in frontal alpha asymmetries. We discuss the findings with respect to the notion that high salience of erotic pictures derives from their potential of satisfying an individuals' need by mere visual inspection, which is not the case for pictures showing other types of motivational stimuli such as food.

  9. Auditory event-related responses to diphthongs in different attention conditions

    DEFF Research Database (Denmark)

    Morris, David Jackson; Steinmetzger, Kurt; Tøndering, John

    2016-01-01

    The modulation of auditory event-related potentials (ERP) by attention generally results in larger amplitudes when stimuli are attended. We measured the P1-N1-P2 acoustic change complex elicited with synthetic overt (second formant, F2 = 1000 Hz) and subtle (F2 = 100 Hz) diphthongs, while subjects...... (i) attended to the auditory stimuli, (ii) ignored the auditory stimuli and watched a film, and (iii) diverted their attention to a visual discrimination task. Responses elicited by diphthongs where F2 values rose and fell were found to be different and this precluded their combined analysis....... Multivariate analysis of ERP components from the rising F2 changes showed main effects of attention on P2 amplitude and latency, and N1-P2 amplitude. P2 amplitude decreased by 40% between the attend and ignore conditions, and by 60% between the attend and divert conditions. The effect of diphthong magnitude...

  10. Neuroprotection against vascular dementia after acupuncture combined with donepezil hydrochloride: P300 event related potential

    Directory of Open Access Journals (Sweden)

    Qiang Liu

    2016-01-01

    Full Text Available Acupuncture can be used to treat various nervous system diseases. Here, 168 vascular dementia patients were orally administered donepezil hydrochloride alone (5 mg/day, once a day for 56 days, or combined with acupuncture at Shenting (DU24, Tianzhu (BL10, Sishencong (Extra, Yintang (Extra, Renzhong (DU26, Neiguan (PC6, Shenmen (HT7, Fengchi (GB20, Wangu (GB12 and Baihui (DU20 (once a day for 56 days. Compared with donepezil hydrochloride alone, P300 event related potential latency was shorter with an increased amplitude in patients treated with donepezil hydrochloride and acupuncture. Mini-Mental State Examination score was also higher. Moreover, these differences in P300 latency were identified within different infarcted regions in patients treated with donepezil hydrochloride and acupuncture. These findings indicate that acupuncture combined with donepezil hydrochloride noticeably improves cognitive function in patients with vascular dementia, and exerts neuroprotective effects against vascular dementia.

  11. Glucose enhancement of event-related potentials associated with episodic memory and attention.

    Science.gov (United States)

    Brown, Louise A; Riby, Leigh M

    2013-04-30

    Previous studies have reported that increasing glycaemia by a glucose-containing drink enhances memory functioning. The aim of the present study was to extend this literature by examining the effects of glucose on episodic memory as well as attention processes, and to investigate associated event-related potential (ERP) markers. Fifteen minutes after treatment (25 g glucose or placebo drink), 35 participants performed an old/new recognition memory task and a Stroop colour naming task. Consistent with previous research, when controlling for glucose regulation, cognitive facilitation was observed behaviourally for verbal memory, but there was also a trend towards attentional facilitation. Furthermore, across both domains, it was the most demanding task conditions that exhibited glucose sensitivity. In support of the behavioural results, the analysis of ERPs across treatment groups revealed an enhanced left-parietal old/new effect related to recollection, and also suggested modulation of attentional processes. The results suggest that glucose may facilitate attention as well as memory.

  12. Aging, working memory capacity and the proactive control of recollection: An event-related potential study

    Science.gov (United States)

    Keating, Jessica; Affleck-Brodie, Caitlin; Wiegand, Ronny

    2017-01-01

    The present study investigated the role of working memory capacity (WMC) in the control of recollection in young and older adults. We used electroencephalographic event-related potentials (ERPs) to examine the effects of age and of individual differences in WMC on the ability to prioritize recollection according to current goals. Targets in a recognition exclusion task were words encoded using two alternative decisions. The left parietal ERP old/new effect was used as an electrophysiological index of recollection, and the selectivity of recollection measured in terms of the difference in its magnitude according to whether recognized items were targets or non-targets. Young adults with higher WMC showed greater recollection selectivity than those with lower WMC, while older adults showed nonselective recollection which did not vary with WMC. The data suggest that aging impairs the ability to engage cognitive control effectively to prioritize what will be recollected. PMID:28727792

  13. Pharmacodynamic Modelling of Placebo and Buprenorphine Effects on Event-Related Potentials in Experimental Pain

    DEFF Research Database (Denmark)

    Juul, Rasmus V; Foster, David J R; Upton, Richard N

    2014-01-01

    The purpose of the study was to investigate placebo and buprenorphine effects on event-related potentials (ERPs) in experimental pain and the potential benefit of population pharmacodynamic modelling in data analysis. Nineteen healthy volunteers received transdermal placebo and buprenorphine...... in a cross-over study. Drug plasma concentrations and ERPs after electrical stimulation at the median nerve with intensity adjusted to pain detection threshold were recorded until 144 hrs after administration. Placebo and concentration-effect models were fitted to data using non-linear mixed......, pharmacodynamic modelling was successfully implemented to allow for placebo and variability correction in ERP of experimental pain. Improved outcome of ERP studies can be expected if variation between subjects and study occasions can be identified and described....

  14. Automatic detection of lexical change: an auditory event-related potential study.

    Science.gov (United States)

    Muller-Gass, Alexandra; Roye, Anja; Kirmse, Ursula; Saupe, Katja; Jacobsen, Thomas; Schröger, Erich

    2007-10-29

    We investigated the detection of rare task-irrelevant changes in the lexical status of speech stimuli. Participants performed a nonlinguistic task on word and pseudoword stimuli that occurred, in separate conditions, rarely or frequently. Task performance for pseudowords was deteriorated relative to words, suggesting unintentional lexical analysis. Furthermore, rare word and pseudoword changes had a similar effect on the event-related potentials, starting as early as 165 ms. This is the first demonstration of the automatic detection of change in lexical status that is not based on a co-occurring acoustic change. We propose that, following lexical analysis of the incoming stimuli, a mental representation of the lexical regularity is formed and used as a template against which lexical change can be detected.

  15. Spatial and Semantic Processing between Audition and Vision: An Event-Related Potential Study

    Directory of Open Access Journals (Sweden)

    Xiaoxi Chen

    2011-10-01

    Full Text Available Using a crossmodal priming paradigm, this study investigated how the brain bound the spatial and semantic features in multisensory processing. The visual stimuli (pictures of animals were presented after the auditory stimuli (sounds of animals, and the stimuli from different modalities may match spatially (or semantically or not. Participants were required to detect the head orientation of the visual target (an oddball paradigm. The event-related potentials (ERPs to the visual stimuli was enhanced by spatial attention (150–170 ms irrespectively of semantic information. The early crossmodal attention effect for the visual stimuli was more negative in the spatial-congruent condition than in the spatial-incongruent condition. By contrast, the later effects of spatial ERPs were significant only for the semantic- congruent condition (250–300 ms. These findings indicated that spatial attention modulated early visual processing, and semantic and spatial features were simultaneously used to orient attention and modulate later processing stages.

  16. Information structure influences depth of syntactic processing: event-related potential evidence for the Chomsky illusion.

    Science.gov (United States)

    Wang, Lin; Bastiaansen, Marcel; Yang, Yufang; Hagoort, Peter

    2012-01-01

    Information structure facilitates communication between interlocutors by highlighting relevant information. It has previously been shown that information structure modulates the depth of semantic processing. Here we used event-related potentials to investigate whether information structure can modulate the depth of syntactic processing. In question-answer pairs, subtle (number agreement) or salient (phrase structure) syntactic violations were placed either in focus or out of focus through information structure marking. P600 effects to these violations reflect the depth of syntactic processing. For subtle violations, a P600 effect was observed in the focus condition, but not in the non-focus condition. For salient violations, comparable P600 effects were found in both conditions. These results indicate that information structure can modulate the depth of syntactic processing, but that this effect depends on the salience of the information. When subtle violations are not in focus, they are processed less elaborately. We label this phenomenon the Chomsky illusion.

  17. Crossmodal effects of Guqin and piano music on selective attention: an event-related potential study.

    Science.gov (United States)

    Zhu, Weina; Zhang, Junjun; Ding, Xiaojun; Zhou, Changle; Ma, Yuanye; Xu, Dan

    2009-11-27

    To compare the effects of music from different cultural environments (Guqin: Chinese music; piano: Western music) on crossmodal selective attention, behavioral and event-related potential (ERP) data in a standard two-stimulus visual oddball task were recorded from Chinese subjects in three conditions: silence, Guqin music or piano music background. Visual task data were then compared with auditory task data collected previously. In contrast with the results of the auditory task, the early (N1) and late (P300) stages exhibited no differences between Guqin and piano backgrounds during the visual task. Taking our previous study and this study together, we can conclude that: although the cultural-familiar music influenced selective attention both in the early and late stages, these effects appeared only within a sensory modality (auditory) but not in cross-sensory modalities (visual). Thus, the musical cultural factor is more obvious in intramodal than in crossmodal selective attention.

  18. Attenuation of deep semantic processing during mind wandering: an event-related potential study.

    Science.gov (United States)

    Xu, Judy; Friedman, David; Metcalfe, Janet

    2018-03-21

    Although much research shows that early sensory and attentional processing is affected by mind wandering, the effect of mind wandering on deep (i.e. semantic) processing is relatively unexplored. To investigate this relation, we recorded event-related potentials as participants studied English-Spanish word pairs, one at a time, while being intermittently probed for whether they were 'on task' or 'mind wandering'. Both perceptual processing, indexed by the P2 component, and deep processing, indexed by a late, sustained slow wave maximal at parietal electrodes, was attenuated during periods preceding participants' mind wandering reports. The pattern when participants were on task, rather than mind wandering, is similar to the subsequent memory or difference in memory effect. These results support previous findings of sensory attenuation during mind wandering, and extend them to a long-duration slow wave by suggesting that the deeper and more sustained levels of processing are also disrupted.

  19. Correlation between event-related potentials and MR measurements in chronic alcoholic patients

    International Nuclear Information System (INIS)

    Kaseda, Yumiko; Miyazato, Yoshikazu; Ogura, Chikara; Nakamoto, Haruo; Uema, Takeshi; Yamamoto, Kazuyoshi; Ohta, Ikuya

    1994-01-01

    Event-related potentials were recorded in 25 abstinent alcoholics, and 25 gender- and age-matched controls during a two-tone discrimination (odd ball) task. All the subjects were free from medication and dextral. MR images were examined in the alcoholics. The amplitudes of N100, N200 and P300 in the alcoholics were reduced compared with those of the controls. In order to identify morphological changes responsible for ERP abnormalities, linear regression analyses were performed between ERP measures and MRI parameters. The amplitude of N100 was inversely correlated with ventricular size. The amplitudes of P300 were inversely correlated with both ventricular size and width of cortical sulci. It was suggested that the N100 abnormality was related to subcortical structure, and P300 alteration was related to both subcortical and cortical structures in the alcoholics. (author)

  20. A new method for detecting interactions between the senses in event-related potentials

    DEFF Research Database (Denmark)

    Gondan, Matthias; Röder, B.

    2006-01-01

    Event-related potentials (ERPs) can be used in multisensory research to determine the point in time when different senses start to interact, for example, the auditory and the visual system. For this purpose, the ERP to bimodal stimuli (AV) is often compared to the sum of the ERPs to auditory (A......) and visual (V) stimuli: AV - (A + V). If the result is non-zero, this is interpreted as an indicator for multisensory interactions. Using this method, several studies have demonstrated auditory-visual interactions as early as 50 ms after stimulus onset. The subtraction requires that A, V, and AV do...... not contain common activity: This activity would be subtracted twice from one ERP and would, therefore, contaminate the result. In the present study, ERPs to unimodal, bimodal, and trimodal auditory, visual, and tactile stimuli (T) were recorded. We demonstrate that (T + TAV) - (TA + TV) is equivalent to AV...

  1. Human event-related brain potentials to auditory periodic noise stimuli.

    Science.gov (United States)

    Kaernbach, C; Schröger, E; Gunter, T C

    1998-02-06

    Periodic noise is perceived as different from ordinary non-repeating noise due to the involvement of echoic memory. Since this stimulus does not contain simple physical cues (such as onsets or spectral shape) that might obscure sensory memory interpretations, it is a valuable tool to study sensory memory functions. We demonstrated for the first time that the processing of periodic noise can be tapped by event-related brain potentials (ERPs). Human subjects received repeating segments of noise embedded in non-repeating noise. They were instructed to detect the periodicity inherent to the stimulation. We observed a central negativity time-locked on the periodic segment that correlated to the subjects behavioral performance in periodicity detection. It is argued that the ERP result indicates an enhancement of sensory-specific processing.

  2. Event-related brain potentials reflect traces of echoic memory in humans.

    Science.gov (United States)

    Winkler, I; Reinikainen, K; Näätänen, R

    1993-04-01

    In sequences of identical auditory stimuli, infrequent deviant stimuli elicit an event-related brain potential component called mismatch negativity (MMN). MMN is presumed to reflect the existence of a memory trace of the frequent stimulus at the moment of presentation of the infrequent stimulus. This hypothesis was tested by applying the recognition-masking paradigm of cognitive psychology. In this paradigm, a masking sound presented shortly before or after a test stimulus diminishes the recognition memory of this stimulus, the more so the shorter the interval between the test and masking stimuli. This interval was varied in the present study. It was found that the MMN amplitude strongly correlated with the subject's ability to discriminate between frequent and infrequent stimuli. This result strongly suggests that MMN provides a measure for a trace of sensory memory, and further, that with MMN, this memory can be studied without performance-related distortions.

  3. Neural correlates of cued recall in young and older adults: an event-related potential study.

    Science.gov (United States)

    Angel, Lucie; Fay, Séverine; Bouazzaoui, Badiâa; Granjon, Lionel; Isingrini, Michel

    2009-01-07

    This experiment investigated age differences in electrophysiological correlates of retrieval success in a word-stem cued recall task. Young adults (M+/-SD: 21.4 years+/-1.9) performed this memory task more accurately than older participants (M+/-SD: 65.1 years+/-3.3). Robust event-related brain potential (ERP) old/new effects were identified in both age groups. The main age differences were observed in latency and lateralization of ERP effects. Young adults exhibited a parietal effect that became focused over left parietal electrodes, whereas no asymmetry was observed in older adults. Moreover, ERP effects were more delayed in the older group. Overall, these findings provide some evidence of the reduction of processing speed during aging and suggest that young and older adults may recruit distinct cerebral patterns during episodic cued recall.

  4. The correlation between motor impairments and event-related desynchronization during motor imagery in ALS patients

    Directory of Open Access Journals (Sweden)

    Kasahara Takashi

    2012-06-01

    Full Text Available Abstract Background The event-related desynchronization (ERD in EEG is known to appear during motor imagery, and is thought to reflect cortical processing for motor preparation. The aim of this study is to examine the modulation of ERD with motor impairment in ALS patients. ERD during hand motor imagery was obtained from 8 ALS patients with a variety of motor impairments. ERD was also obtained from age-matched 11 healthy control subjects with the same motor task. The magnitude and frequency of ERD were compared between groups for characterization of ALS specific changes. Results The ERD of ALS patients were significantly smaller than those of control subjects. Bulbar function and ERD were negatively correlated in ALS patients. Motor function of the upper extremities did was uncorrelated with ERD. Conclusions ALS patients with worsened bulbar scales may show smaller ERD. Motor function of the upper extremities did was uncorrelated with ERD.

  5. A comparative study of event-related coupling patterns during an auditory oddball task in schizophrenia

    Science.gov (United States)

    Bachiller, Alejandro; Poza, Jesús; Gómez, Carlos; Molina, Vicente; Suazo, Vanessa; Hornero, Roberto

    2015-02-01

    Objective. The aim of this research is to explore the coupling patterns of brain dynamics during an auditory oddball task in schizophrenia (SCH). Approach. Event-related electroencephalographic (ERP) activity was recorded from 20 SCH patients and 20 healthy controls. The coupling changes between auditory response and pre-stimulus baseline were calculated in conventional EEG frequency bands (theta, alpha, beta-1, beta-2 and gamma), using three coupling measures: coherence, phase-locking value and Euclidean distance. Main results. Our results showed a statistically significant increase from baseline to response in theta coupling and a statistically significant decrease in beta-2 coupling in controls. No statistically significant changes were observed in SCH patients. Significance. Our findings support the aberrant salience hypothesis, since SCH patients failed to change their coupling dynamics between stimulus response and baseline when performing an auditory cognitive task. This result may reflect an impaired communication among neural areas, which may be related to abnormal cognitive functions.

  6. Event-related potentials to visual, auditory, and bimodal (combined auditory-visual) stimuli.

    Science.gov (United States)

    Isoğlu-Alkaç, Ummühan; Kedzior, Karina; Keskindemirci, Gonca; Ermutlu, Numan; Karamursel, Sacit

    2007-02-01

    The purpose of this study was to investigate the response properties of event related potentials to unimodal and bimodal stimulations. The amplitudes of N1 and P2 were larger during bimodal evoked potentials (BEPs) than auditory evoked potentials (AEPs) in the anterior sites and the amplitudes of P1 were larger during BEPs than VEPs especially at the parieto-occipital locations. Responses to bimodal stimulation had longer latencies than responses to unimodal stimulation. The N1 and P2 components were larger in amplitude and longer in latency during the bimodal paradigm and predominantly occurred at the anterior sites. Therefore, the current bimodal paradigm can be used to investigate the involvement and location of specific neural generators that contribute to higher processing of sensory information. Moreover, this paradigm may be a useful tool to investigate the level of sensory dysfunctions in clinical samples.

  7. Aging, working memory capacity and the proactive control of recollection: An event-related potential study.

    Directory of Open Access Journals (Sweden)

    Jessica Keating

    Full Text Available The present study investigated the role of working memory capacity (WMC in the control of recollection in young and older adults. We used electroencephalographic event-related potentials (ERPs to examine the effects of age and of individual differences in WMC on the ability to prioritize recollection according to current goals. Targets in a recognition exclusion task were words encoded using two alternative decisions. The left parietal ERP old/new effect was used as an electrophysiological index of recollection, and the selectivity of recollection measured in terms of the difference in its magnitude according to whether recognized items were targets or non-targets. Young adults with higher WMC showed greater recollection selectivity than those with lower WMC, while older adults showed nonselective recollection which did not vary with WMC. The data suggest that aging impairs the ability to engage cognitive control effectively to prioritize what will be recollected.

  8. Aesthetic appreciation: event-related field and time-frequency analyses.

    Science.gov (United States)

    Munar, Enric; Nadal, Marcos; Castellanos, Nazareth P; Flexas, Albert; Maestú, Fernando; Mirasso, Claudio; Cela-Conde, Camilo J

    2011-01-01

    Improvements in neuroimaging methods have afforded significant advances in our knowledge of the cognitive and neural foundations of aesthetic appreciation. We used magnetoencephalography (MEG) to register brain activity while participants decided about the beauty of visual stimuli. The data were analyzed with event-related field (ERF) and Time-Frequency (TF) procedures. ERFs revealed no significant differences between brain activity related with stimuli rated as "beautiful" and "not beautiful." TF analysis showed clear differences between both conditions 400 ms after stimulus onset. Oscillatory power was greater for stimuli rated as "beautiful" than those regarded as "not beautiful" in the four frequency bands (theta, alpha, beta, and gamma). These results are interpreted in the frame of synchronization studies.

  9. Processing of emotional faces in congenital amusia: An emotional music priming event-related potential study.

    Science.gov (United States)

    Zhishuai, Jin; Hong, Liu; Daxing, Wu; Pin, Zhang; Xuejing, Lu

    2017-01-01

    Congenital amusia is characterized by lifelong impairments in music perception and processing. It is unclear whether pitch detection deficits impact amusic individuals' perception of musical emotion. In the current work, 19 amusics and 21 healthy controls were subjected to electroencephalography (EEG) while being exposed to music excerpts and emotional faces. We assessed each individual's ability to discriminate positive- and negative-valenced emotional faces and analyzed electrophysiological indices, in the form of event-related potentials (ERPs) recorded at 32 sites, following exposure to emotionally positive or negative music excerpts. We observed smaller N2 amplitudes in response to facial expressions in the amusia group than in the control group, suggesting that amusics were less affected by the musical stimuli. The late-positive component (LPC) in amusics was similar to that in controls. Our results suggest that the neurocognitive deficit characteristic of congenital amusia is fundamentally an impairment in musical information processing rather than an impairment in emotional processing.

  10. Processing of emotional faces in congenital amusia: An emotional music priming event-related potential study

    Directory of Open Access Journals (Sweden)

    Jin Zhishuai

    2017-01-01

    Full Text Available Congenital amusia is characterized by lifelong impairments in music perception and processing. It is unclear whether pitch detection deficits impact amusic individuals' perception of musical emotion. In the current work, 19 amusics and 21 healthy controls were subjected to electroencephalography (EEG while being exposed to music excerpts and emotional faces. We assessed each individual's ability to discriminate positive- and negative-valenced emotional faces and analyzed electrophysiological indices, in the form of event-related potentials (ERPs recorded at 32 sites, following exposure to emotionally positive or negative music excerpts. We observed smaller N2 amplitudes in response to facial expressions in the amusia group than in the control group, suggesting that amusics were less affected by the musical stimuli. The late-positive component (LPC in amusics was similar to that in controls. Our results suggest that the neurocognitive deficit characteristic of congenital amusia is fundamentally an impairment in musical information processing rather than an impairment in emotional processing.

  11. Neural network approach in multichannel auditory event-related potential analysis.

    Science.gov (United States)

    Wu, F Y; Slater, J D; Ramsay, R E

    1994-04-01

    Even though there are presently no clearly defined criteria for the assessment of P300 event-related potential (ERP) abnormality, it is strongly indicated through statistical analysis that such criteria exist for classifying control subjects and patients with diseases resulting in neuropsychological impairment such as multiple sclerosis (MS). We have demonstrated the feasibility of artificial neural network (ANN) methods in classifying ERP waveforms measured at a single channel (Cz) from control subjects and MS patients. In this paper, we report the results of multichannel ERP analysis and a modified network analysis methodology to enhance automation of the classification rule extraction process. The proposed methodology significantly reduces the work of statistical analysis. It also helps to standardize the criteria of P300 ERP assessment and facilitate the computer-aided analysis on neuropsychological functions.

  12. The delay effect on outcome evaluation: results from an Event-related Potential study

    Directory of Open Access Journals (Sweden)

    Chen eQu

    2013-11-01

    Full Text Available Behavioral studies demonstrate that the timing of receiving gains or losses affects decision-making, a phenomenon known as temporal discounting, as participants are inclined to prefer immediate rewards over delayed ones and vice versa for losses. The present study used the event-related potential (ERP technique with a simple gambling task to investigate how delayed rewards and losses affected the brain activity in outcome evaluations made by 20 young adults. Statistical analysis revealed a larger feedback related negativity (FRN effect between loss and gain following immediate outcomes than following future outcomes. In addition, delay impacted FRN only in gain conditions, with delayed winning eliciting a more negative FRN than immediatewinning. These results suggest that temporal discounting and sign effect could be encoded in the FRN in the early stage of outcome evaluation.

  13. Hostile attribution biases for relationally provocative situations and event-related potentials.

    Science.gov (United States)

    Godleski, Stephanie A; Ostrov, Jamie M; Houston, Rebecca J; Schlienz, Nicolas J

    2010-04-01

    This exploratory study investigates how hostile attribution biases for relationally provocative situations may be related to neurocognitive processing using the P300 event-related potential. Participants were 112 (45 women) emerging adults enrolled in a large, public university in upstate New York. Participants completed self-report measures on relational aggression and hostile attribution biases and performed an auditory perseveration task to elicit the P300. It was found that hostile attribution biases for relational provocation situations was associated with a larger P300 amplitude above and beyond the role of hostile attribution biases for instrumental situations, relational aggression, and gender. Larger P300 amplitude is interpreted to reflect greater allocation of cognitive resources or enhanced "attending" to salient stimuli. Implications for methodological approaches to studying aggression and hostile attribution biases and for theory are discussed, as well as implications for the fields of developmental psychology and psychopathology. Copyright 2010 Elsevier B.V. All rights reserved.

  14. Additive effects of repetition and predictability during comprehension: evidence from event-related potentials.

    Directory of Open Access Journals (Sweden)

    Wing-Yee Chow

    Full Text Available Previous research has shown that neural responses to words during sentence comprehension are sensitive to both lexical repetition and a word's predictability in context. While previous research has often contrasted the effects of these variables (e.g. by looking at cases in which word repetition violates sentence-level constraints, little is known about how they work in tandem. In the current study we examine how recent exposure to a word and its predictability in context combine to impact lexical semantic processing. We devise a novel paradigm that combines reading comprehension with a recognition memory task, allowing for an orthogonal manipulation of a word's predictability and its repetition status. Using event-related brain potentials (ERPs, we show that word repetition and predictability have qualitatively similar and additive effects on the N400 amplitude. We propose that prior exposure to a word and predictability impact lexical semantic processing in an additive and independent fashion.

  15. Digital memory encoding in Chinese dyscalculia: An event-related potential study.

    Science.gov (United States)

    Wang, Enguo; Qin, Shutao; Chang, MengYan; Zhu, Xiangru

    2014-10-22

    This study reports the neurophysiological and behavioral correlates of digital memory encoding features in Chinese individuals with and without dyscalculia. Eighteen children with dyscalculia (ages 11.5-13.5) and 18 matched controls were tested, and their event-related potentials (ERPs) were digitally recorded simultaneously with behavioral measures. The results showed that both groups had a significant Dm effect, and this effect was greater in the control group. In the 300-400-ms, 400-500-ms, and 600-700-ms processing stages, both groups showed significant differences of digital memory encoding in the frontal, central, and parietal regions. In the 500-600-ms period, the Dm effect in the control group was significantly greater than that in the dyscalculia group only in the parietal region. These results suggest that individuals with dyscalculia exhibit impaired digital memory encoding and deficits in psychological resource allocation. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Comparing the temporal dynamics of thematic and taxonomic processing using event-related potentials.

    Directory of Open Access Journals (Sweden)

    Olivera Savic

    Full Text Available We report the results of a study comparing the temporal dynamics of thematic and taxonomic knowledge activation in a picture-word priming paradigm using event-related potentials. Although we found no behavioral differences between thematic and taxonomic processing, ERP data revealed distinct patterns of N400 and P600 amplitude modulation for thematic and taxonomic priming. Thematically related target stimuli elicited less negativity than taxonomic targets between 280-460 ms after stimulus onset, suggesting easier semantic processing of thematic than taxonomic relationships. Moreover, P600 mean amplitude was significantly increased for taxonomic targets between 520-600 ms, consistent with a greater need for stimulus reevaluation in that condition. These results offer novel evidence in favor of a dissociation between thematic and taxonomic thinking in the early phases of conceptual evaluation.

  17. Comparing the temporal dynamics of thematic and taxonomic processing using event-related potentials.

    Science.gov (United States)

    Savic, Olivera; Savic, Andrej M; Kovic, Vanja

    2017-01-01

    We report the results of a study comparing the temporal dynamics of thematic and taxonomic knowledge activation in a picture-word priming paradigm using event-related potentials. Although we found no behavioral differences between thematic and taxonomic processing, ERP data revealed distinct patterns of N400 and P600 amplitude modulation for thematic and taxonomic priming. Thematically related target stimuli elicited less negativity than taxonomic targets between 280-460 ms after stimulus onset, suggesting easier semantic processing of thematic than taxonomic relationships. Moreover, P600 mean amplitude was significantly increased for taxonomic targets between 520-600 ms, consistent with a greater need for stimulus reevaluation in that condition. These results offer novel evidence in favor of a dissociation between thematic and taxonomic thinking in the early phases of conceptual evaluation.

  18. Effects of rearranged vision on event-related lateralizations of the EEG during pointing.

    Science.gov (United States)

    Berndt, Isabelle; Franz, Volker H; Bülthoff, Heinrich H; Gotz, Karl G; Wascher, Edmund

    2005-01-01

    We used event-related lateralizations of the EEG (ERLs) and reversed vision to study visuomotor processing with conflicting proprioceptive and visual information during pointing. Reversed vision decreased arm-related lateralization, probably reflecting the simultaneous activity of left and right arm specific neurons: neurons in the hemisphere contralateral to the observed action were probably activated by visual feedback, neurons in the hemisphere contralateral to the response side by the somatomotor feedback. Lateralization related to the target in parietal cortex increased, indicating that visual to motor transformation in parietal cortex required additional time and resources with reversed vision. A short period of adaptation to an additional lateral displacement of the visual field increased arm-contralateral activity in parietal cortex during the movement. This is in agreement with the, which showed that adaptation to a lateral displacement of the visual field is reflected in increased parietal involvement during pointing.

  19. P300 component of event-related potentials in persons with asperger disorder.

    Science.gov (United States)

    Iwanami, Akira; Okajima, Yuka; Ota, Haruhisa; Tani, Masayuki; Yamada, Takashi; Yamagata, Bun; Hashimoto, Ryuichiro; Kanai, Chieko; Takashio, Osamu; Inamoto, Atsuko; Ono, Taisei; Takayama, Yukiko; Kato, Nobumasa

    2014-10-01

    In the present study, we investigated auditory event-related potentials in adults with Asperger disorder and normal controls using an auditory oddball task and a novelty oddball task. Task performance and the latencies of P300 evoked by both target and novel stimuli in the two tasks did not differ between the two groups. Analysis of variance revealed that there was a significant interaction effect between group and electrode site on the mean amplitude of the P300 evoked by novel stimuli, which indicated that there was an altered distribution of the P300 in persons with Asperger disorder. In contrast, there was no significant interaction effect on the mean P300 amplitude elicited by target stimuli. Considering that P300 comprises two main subcomponents, frontal-central-dominant P3a and parietal-dominant P3b, our results suggested that persons with Asperger disorder have enhanced amplitude of P3a, which indicated activated prefrontal function in this task.

  20. Bilingualism and increased attention to speech: Evidence from event-related potentials.

    Science.gov (United States)

    Kuipers, Jan Rouke; Thierry, Guillaume

    2015-10-01

    A number of studies have shown that from an early age, bilinguals outperform their monolingual peers on executive control tasks. We previously found that bilingual children and adults also display greater attention to unexpected language switches within speech. Here, we investigated the effect of a bilingual upbringing on speech perception in one language. We recorded monolingual and bilingual toddlers' event-related potentials (ERPs) to spoken words preceded by pictures. Words matching the picture prime elicited an early frontal positivity in bilingual participants only, whereas later ERP amplitudes associated with semantic processing did not differ between groups. These results add to the growing body of evidence that bilingualism increases overall attention during speech perception whilst semantic integration is unaffected. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  1. Self-relevant beauty evaluation: Evidence from an event-related potentials study.

    Science.gov (United States)

    Kong, Fanchang; Zhang, Yan; Tian, Yuan; Fan, Cuiying; Zhou, Zongkui

    2015-03-01

    This study examines the electrophysiological correlates of beauty evaluation when participants performed the self-reference task. About 13 (7 men, 6 women) undergraduates participated in the experiment using event-related potentials. Results showed that the response to self-relevant information was faster compared to other-relevant information and no significant differences for self-relevant relative to mother-relevant information were observed. Both physical and interior beauty words for self-relevant information showed an enhanced late positive component as compared to other-relevant information. Physical beauty for self-relevant information yielded a larger late positive component in contrast to mother-relevant information but not for interior beauty. This study indicates that beauty is specific to the person who judges it though an individual and one's mother may hold similar views of interior beauty.

  2. Modulations of 'late' event-related brain potentials in humans by dynamic audiovisual speech stimuli.

    Science.gov (United States)

    Lebib, Riadh; Papo, David; Douiri, Abdel; de Bode, Stella; Gillon Dowens, Margaret; Baudonnière, Pierre-Marie

    2004-11-30

    Lipreading reliably improve speech perception during face-to-face conversation. Within the range of good dubbing, however, adults tolerate some audiovisual (AV) discrepancies and lipreading, then, can give rise to confusion. We used event-related brain potentials (ERPs) to study the perceptual strategies governing the intermodal processing of dynamic and bimodal speech stimuli, either congruently dubbed or not. Electrophysiological analyses revealed that non-coherent audiovisual dubbings modulated in amplitude an endogenous ERP component, the N300, we compared to a 'N400-like effect' reflecting the difficulty to integrate these conflicting pieces of information. This result adds further support for the existence of a cerebral system underlying 'integrative processes' lato sensu. Further studies should take advantage of this 'N400-like effect' with AV speech stimuli to open new perspectives in the domain of psycholinguistics.

  3. Orthographic recognition in late adolescents: an assessment through event-related brain potentials.

    Science.gov (United States)

    González-Garrido, Andrés Antonio; Gómez-Velázquez, Fabiola Reveca; Rodríguez-Santillán, Elizabeth

    2014-04-01

    Reading speed and efficiency are achieved through the automatic recognition of written words. Difficulties in learning and recognizing the orthography of words can arise despite reiterative exposure to texts. This study aimed to investigate, in native Spanish-speaking late adolescents, how different levels of orthographic knowledge might result in behavioral and event-related brain potential differences during the recognition of orthographic errors. Forty-five healthy high school students were selected and divided into 3 equal groups (High, Medium, Low) according to their performance on a 5-test battery of orthographic knowledge. All participants performed an orthographic recognition task consisting of the sequential presentation of a picture (object, fruit, or animal) followed by a correctly, or incorrectly, written word (orthographic mismatch) that named the picture just shown. Electroencephalogram (EEG) recording took place simultaneously. Behavioral results showed that the Low group had a significantly lower number of correct responses and increased reaction times while processing orthographical errors. Tests showed significant positive correlations between higher performance on the experimental task and faster and more accurate reading. The P150 and P450 components showed higher voltages in the High group when processing orthographic errors, whereas N170 seemed less lateralized to the left hemisphere in the lower orthographic performers. Also, trials with orthographic errors elicited a frontal P450 component that was only evident in the High group. The present results show that higher levels of orthographic knowledge correlate with high reading performance, likely because of faster and more accurate perceptual processing, better visual orthographic representations, and top-down supervision, as the event-related brain potential findings seem to suggest.

  4. [Differential effects of attention deficit/hyperactivity disorder subtypes in event-related potentials].

    Science.gov (United States)

    Tamayo-Orrego, Lukas; Osorio Forero, Alejandro; Quintero Giraldo, Lina Paola; Parra Sánchez, José Hernán; Varela, Vilma; Restrepo, Francia

    2015-01-01

    To better understand the neurophysiological substrates in attention deficit/hyperactivity disorder (ADHD), a study was performed on of event-related potentials (ERPs) in Colombian patients with inattentive and combined ADHD. A case-control, cross-sectional study was designed. The sample was composed of 180 subjects between 5 and 15 years of age (mean, 9.25±2.6), from local schools in Manizales. The sample was divided equally in ADHD or control groups and the subjects were paired by age and gender. The diagnosis was made using the DSM-IV-TR criteria, the Conners and WISC-III test, a psychiatric interview (MINIKID), and a medical evaluation. ERPs were recorded in a visual and auditory passive oddball paradigm. Latency and amplitude of N100, N200 and P300 components for common and rare stimuli were used for statistical comparisons. ADHD subjects show differences in the N200 amplitude and P300 latency in the auditory task. The N200 amplitude was reduced in response to visual stimuli. ADHD subjects with combined symptoms show a delayed P300 in response to auditory stimuli, whereas inattentive subjects exhibited differences in the amplitude of N100 and N200. Combined ADHD patients showed longer N100 latency and smaller N200-P300 amplitude compared to inattentive ADHD subjects. The results show differences in the event-related potentials between combined and inattentive ADHD subjects. Copyright © 2014 Asociación Colombiana de Psiquiatría. Publicado por Elsevier España. All rights reserved.

  5. A brief history of people and events related to atomic weapons testing in the Marshall Islands.

    Science.gov (United States)

    Simon, S L

    1997-07-01

    The events related to nuclear testing in the Marshall Islands began at the end of WWII when the U.S. began an initiative to determine the effect of nuclear weapons on naval vessels and on the performance of military personnel. The first tests took place in 1946 even though the area known as Micronesia was not entrusted to the U.S. by the United Nations until 1947. Beginning with the first relocation of the Bikini people to Rongerik Atoll in 1946, the saga of the Marshall Islands involvement in the atomic age began. Although the testing program was limited to the years 1946 through 1958, many of the consequences and events related to the testing program continued over the decades since. That story is still ongoing with programs currently underway to attempt to resettle previously displaced communities, remediate contaminated islands, and to settle claims of damages to individuals and communities. The history of the years subsequent to 1958 are a mixed chronicle of a few original scientific investigations aimed at understanding the coral atoll environment, continued surveillance of the acutely exposed Marshallese, some efforts at cleanup and remediation, numerous monitoring programs and many studies repeated either for credibility purposes, to satisfy international demands or because the changing state of knowledge of radiation protection has necessitated us to rethink earlier beliefs and conclusions about late health effects and social consequences. The objective of this paper is to briefly note many of the historical and political events, scientific studies, persons and publications from 1946 to the present that relate to atomic weapons testing in the Marshall Islands.

  6. Self-Referential Processing in Adolescents: Stability of Behavioral and Event-Related Potential Markers

    Science.gov (United States)

    Auerbach, Randy P.; Bondy, Erin; Stanton, Colin H.; Webb, Christian A.; Shankman, Stewart A.; Pizzagalli, Diego A.

    2016-01-01

    The self-referential encoding task (SRET)—an implicit measure of self-schema—has been used widely to probe cognitive biases associated with depression, including among adolescents. However, research testing the stability of behavioral and electrocortical effects is sparse. Therefore, the current study sought to evaluate the stability of behavioral markers and event-related potentials (ERP) elicited from the SRET over time in healthy, female adolescents (n = 31). At baseline, participants were administered a diagnostic interview and a self-report measure of depression severity. In addition, they completed the SRET while 128-channel event-related potential (ERP) data were recorded to examine early (P1) and late (late positive potential [LPP]) ERPs. Three months later, participants were re-administered the depression self-report measure and the SRET in conjunction with ERPs. Results revealed that healthy adolescents endorsed, recalled, and recognized more positive and fewer negative words at each assessment, and these effects were stable over time (rs = 0.44–0.83). Similarly, they reported a faster reaction time when endorsing self-relevant positive words, as opposed to negative words, at both the initial and follow-up assessment (r = 0.82). Second, ERP responses, specifically potentiated P1 and late LPP positivity to positive versus negative words, were consistent over time (rs = 0.56–0.83), and the internal reliability of ERPs were robust at each time point (rs = 0.52–0.80). As a whole, these medium-to-large effects suggest that the SRET is a reliable behavioral and neural probe of self-referential processing. PMID:27302282

  7. A cognitive stressor for event-related potential studies: the Portland arithmetic stress task.

    Science.gov (United States)

    Atchley, Rachel; Ellingson, Roger; Klee, Daniel; Memmott, Tabatha; Oken, Barry

    2017-05-01

    In this experiment, we developed and evaluated the Portland Arithmetic Stress Task (PAST) as a cognitive stressor to evaluate acute and sustained stress reactivity for event-related potential (ERP) studies. The PAST is a titrated arithmetic task adapted from the Montreal Imaging Stress Task (MIST), with added experimental control over presentation parameters, improved and synchronized acoustic feedback and generation of timing markers needed for physiological analyzes of real-time brain activity. Thirty-one older adults (M = 60 years) completed the PAST. EEG was recorded to assess feedback-related negativity (FRN) and the magnitude of the stress response through autonomic nervous system activity and salivary cortisol. Physiological measures other than EEG included heart rate, respiration rate, heart rate variability, blood pressure and salivary cortisol. These measures were collected at several time points throughout the task. Feedback-related negativity evoked-potential responses were elicited and they significantly differed depending on whether positive or negative feedback was received. The PAST also increased systolic blood pressure, heart rate variability and respiration rates compared to a control condition attentional task. These preliminary results suggest that the PAST is an effective cognitive stressor. Successful measurement of the feedback-related negativity suggests that the PAST is conducive to EEG and time-sensitive ERP experiments. Moreover, the physiological findings support the PAST as a potent method for inducing stress in older adult participants. Further research is needed to confirm these results, but the PAST shows promise as a tool for cognitive stress induction for time-locked event-related potential experiments.

  8. Different event-related patterns of gamma-band power in brain waves of fast- and slow-reacting subjects.

    Science.gov (United States)

    Jokeit, H; Makeig, S

    1994-01-01

    Fast- and slow-reacting subjects exhibit different patterns of gamma-band electroencephalogram (EEG) activity when responding as quickly as possible to auditory stimuli. This result appears to confirm long-standing speculations of Wundt that fast- and slow-reacting subjects produce speeded reactions in different ways and demonstrates that analysis of event-related changes in the amplitude of EEG activity recorded from the human scalp can reveal information about event-related brain processes unavailable using event-related potential measures. Time-varying spectral power in a selected (35- to 43-Hz) gamma frequency band was averaged across trials in two experimental conditions: passive listening and speeded reacting to binaural clicks, forming 40-Hz event-related spectral responses. Factor analysis of between-subject event-related spectral response differences split subjects into two near-equal groups composed of faster- and slower-reacting subjects. In faster-reacting subjects, 40-Hz power peaked near 200 ms and 400 ms poststimulus in the react condition, whereas in slower-reacting subjects, 40-Hz power just before stimulus delivery was larger in the react condition. These group differences were preserved in separate averages of relatively long and short reaction-time epochs for each group. gamma-band (20-60 Hz)-filtered event-related potential response averages did not differ between the two groups or conditions. Because of this and because gamma-band power in the auditory event-related potential is small compared with the EEG, the observed event-related spectral response features must represent gamma-band EEG activity reliably induced by, but not phase-locked to, experimental stimuli or events. PMID:8022783

  9. Volumetric composition in composites and historical data

    DEFF Research Database (Denmark)

    Lilholt, Hans; Madsen, Bo

    2013-01-01

    The obtainable volumetric composition in composites is of importance for the prediction of mechanical and physical properties, and in particular to assess the best possible (normally the highest) values for these properties. The volumetric model for the composition of (fibrous) composites gives...... guidance to the optimal combination of fibre content, matrix content and porosity content, in order to achieve the best obtainable properties. Several composite materials systems have been shown to be handleable with this model. An extensive series of experimental data for the system of cellulose fibres...... and polymer (resin) was produced in 1942 – 1944, and these data have been (re-)analysed by the volumetric composition model, and the property values for density, stiffness and strength have been evaluated. Good agreement has been obtained and some further observations have been extracted from the analysis....

  10. Process conditions and volumetric composition in composites

    DEFF Research Database (Denmark)

    Madsen, Bo

    2013-01-01

    The obtainable volumetric composition in composites is linked to the gravimetric composition, and it is influenced by the conditions of the manufacturing process. A model for the volumetric composition is presented, where the volume fractions of fibers, matrix and porosity are calculated...... as a function of the fiber weight fraction, and where parameters are included for the composite microstructure, and the fiber assembly compaction behavior. Based on experimental data of composites manufactured with different process conditions, together with model predictions, different types of process related...... effects are analyzed. The applied consolidation pressure is found to have a marked effect on the volumetric composition. A power-law relationship is found to well describe the found relations between the maximum obtainable fiber volume fraction and the consolidation pressure. The degree of fiber...

  11. Lexical decision making in adults with dyslexia: an event-related potential study

    Directory of Open Access Journals (Sweden)

    Karen E. Waldie

    2012-12-01

    Full Text Available http://dx.doi.org/10.5007/2175-8026.2012n63p37   Performance on a lexical decision task was investigated in 12 English speaking adults with dyslexia.  two age-matched comparison groups of unimpaired readers were included: 14 monolingual adults and 15 late proficient bilinguals. The aim of the study was to determine the timing of neural events with event-related potentials (ErPs during lexical decision-making between individuals with dyslexia and unimpaired readers (both unilingual and bilingual. ErPs were calculated for posterior sites in the left and right hemispheres and the P1 and n170 components were compared between groups. Event-related EEG  coherence (measuring  the synchrony of neural events during lexical tasks both between and within cerebral hemispheres was also calculated for seven electrode pairs (three pairs at symmetrical locations between hemispheres, and two pairs within each hemisphere. We chose to recruit two comparison groups of unimpaired readers to better clarify the findings resulting from the right hemisphere (EEG coherence analysis. That is, both late-proficient bilinguals and adults with dyslexia are thought to rely on right hemisphere resources during reading. We hypothesized that those with dyslexia would show less within-hemisphere coherence and more between-hemisphere coherence than bilingual individuals. dyslexics had both lower amplitude and longer latency n170 activation than unimpaired readers, suggesting asynchronous neural activity. Dyslexics showed greater synchrony between hemispheres in gamma range frequencies whereas the bilingual group showed greater synchrony in the theta frequency band (both within and between hemispheres. This study demonstrates that individuals with developmental dyslexia have reduced amplitudes in the n170 and higher synchrony between hemispheres during a reading task. The differences may be due to an asynchrony of neuronal activity at the point where

  12. Neural correlates of economic value and valuation context: an event-related potential study.

    Science.gov (United States)

    Tyson-Carr, John; Kokmotou, Katerina; Soto, Vicente; Cook, Stephanie; Fallon, Nicholas; Giesbrecht, Timo; Stancak, Andrej

    2018-05-01

    The value of environmental cues and internal states is continuously evaluated by the human brain, and it is this subjective value that largely guides decision making. The present study aimed to investigate the initial value attribution process, specifically the spatiotemporal activation patterns associated with values and valuation context, using electroencephalographic event-related potentials (ERPs). Participants completed a stimulus rating task in which everyday household items marketed up to a price of £4 were evaluated with respect to their desirability or material properties. The subjective values of items were evaluated as willingness to pay (WTP) in a Becker-DeGroot-Marschak auction. On the basis of the individual's subjective WTP values, the stimuli were divided into high- and low-value items. Source dipole modeling was applied to estimate the cortical sources underlying ERP components modulated by subjective values (high vs. low WTP) and the evaluation condition (value-relevant vs. value-irrelevant judgments). Low-WTP items and value-relevant judgments both led to a more pronounced N2 visual evoked potential at right frontal scalp electrodes. Source activity in right anterior insula and left orbitofrontal cortex was larger for low vs. high WTP at ∼200 ms. At a similar latency, source activity in right anterior insula and right parahippocampal gyrus was larger for value-relevant vs. value-irrelevant judgments. A stronger response for low- than high-value items in anterior insula and orbitofrontal cortex appears to reflect aversion to low-valued item acquisition, which in an auction experiment would be perceived as a relative loss. This initial low-value bias occurs automatically irrespective of the valuation context. NEW & NOTEWORTHY We demonstrate the spatiotemporal characteristics of the brain valuation process using event-related potentials and willingness to pay as a measure of subjective value. The N2 component resolves values of objects with a

  13. Incidental encoding of emotional pictures: affective bias studied through event related brain potentials.

    Science.gov (United States)

    Tapia, Manuel; Carretié, Luis; Sierra, Benjamín; Mercado, Francisco

    2008-06-01

    Emotional stimuli are better remembered than neutral stimuli. Most of the studies taking into account this emotional bias refer to explicit memory, use behavioral measures of the recall and predict better recall of negative stimuli. The few studies taking into account implicit memory and the valence emotional dimension are inconclusive on the effect of the stimulus' emotional valence. In the present study, 120 pictures (30 positive, 30 negative, 30 relaxing and 30 neutral) were shown to, and assessed by, 28 participants (study phase). Subsequently, event related brain potentials (ERPs) were recorded during the presentation of 120 new (shown for the first time) and 120 old (already shown in the study phase) pictures (test phase). No explicit instructions or clues related to recovery were given to participants, and a distractor task was employed, in order to maintain implicit the memory assessment. As expected from other studies' data, our results showed that old stimuli elicited an enhanced late positive component 450 ms after stimulus onset (repetition effect). Moreover, this effect was modulated by the stimuli's emotional valence, since the most positively valenced stimuli were associated with a decreased repetition effect with respect to the most negatively valenced stimuli. This effect was located at ventromedial prefrontal cortex. These results suggest the existence of a valence-mediated bias in implicit memory.

  14. The time course of implicit processing of erotic pictures: an event-related potential study.

    Science.gov (United States)

    Feng, Chunliang; Wang, Lili; Wang, Naiyi; Gu, Ruolei; Luo, Yue-Jia

    2012-12-13

    The current study investigated the time course of the implicit processing of erotic stimuli using event-related potentials (ERPs). ERPs elicited by erotic pictures were compared with those by three other types of pictures: non-erotic positive, negative, and neutral pictures. We observed that erotic pictures evoked enhanced neural responses compared with other pictures at both early (P2/N2) and late (P3/positive slow wave) temporal stages. These results suggested that erotic pictures selectively captured individuals' attention at early stages and evoked deeper processing at late stages. More importantly, the amplitudes of P2, N2, and P3 only discriminated between erotic and non-erotic (i.e., positive, neutral, and negative) pictures. That is, no difference was revealed among non-erotic pictures, although these pictures differed in both valence and arousal. Thus, our results suggest that the erotic picture processing is beyond the valence and arousal. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. From sensation to percept: the neural signature of auditory event-related potentials.

    Science.gov (United States)

    Joos, Kathleen; Gilles, Annick; Van de Heyning, Paul; De Ridder, Dirk; Vanneste, Sven

    2014-05-01

    An external auditory stimulus induces an auditory sensation which may lead to a conscious auditory perception. Although the sensory aspect is well known, it is still a question how an auditory stimulus results in an individual's conscious percept. To unravel the uncertainties concerning the neural correlates of a conscious auditory percept, event-related potentials may serve as a useful tool. In the current review we mainly wanted to shed light on the perceptual aspects of auditory processing and therefore we mainly focused on the auditory late-latency responses. Moreover, there is increasing evidence that perception is an active process in which the brain searches for the information it expects to be present, suggesting that auditory perception requires the presence of both bottom-up, i.e. sensory and top-down, i.e. prediction-driven processing. Therefore, the auditory evoked potentials will be interpreted in the context of the Bayesian brain model, in which the brain predicts which information it expects and when this will happen. The internal representation of the auditory environment will be verified by sensation samples of the environment (P50, N100). When this incoming information violates the expectation, it will induce the emission of a prediction error signal (Mismatch Negativity), activating higher-order neural networks and inducing the update of prior internal representations of the environment (P300). Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. Subliminal Emotional Words Impact Syntactic Processing: Evidence from Performance and Event-Related Brain Potentials

    Directory of Open Access Journals (Sweden)

    Laura Jiménez-Ortega

    2017-04-01

    Full Text Available Recent studies demonstrate that syntactic processing can be affected by emotional information and that subliminal emotional information can also affect cognitive processes. In this study, we explore whether unconscious emotional information may also impact syntactic processing. In an Event-Related brain Potential (ERP study, positive, neutral and negative subliminal adjectives were inserted within neutral sentences, just before the presentation of the supraliminal adjective. They could either be correct (50% or contain a morphosyntactic violation (number or gender disagreements. Larger error rates were observed for incorrect sentences than for correct ones, in contrast to most studies using supraliminal information. Strikingly, emotional adjectives affected the conscious syntactic processing of sentences containing morphosyntactic anomalies. The neutral condition elicited left anterior negativity (LAN followed by a P600 component. However, a lack of anterior negativity and an early P600 onset for the negative condition were found, probably as a result of the negative subliminal correct adjective capturing early syntactic resources. Positive masked adjectives in turn prompted an N400 component in response to morphosyntactic violations, probably reflecting the induction of a heuristic processing mode involving access to lexico-semantic information to solve agreement anomalies. Our results add to recent evidence on the impact of emotional information on syntactic processing, while showing that this can occur even when the reader is unaware of the emotional stimuli.

  17. Cortical excitability correlates with the event-related desynchronization during brain-computer interface control

    Science.gov (United States)

    Daly, Ian; Blanchard, Caroline; Holmes, Nicholas P.

    2018-04-01

    Objective. Brain-computer interfaces (BCIs) based on motor control have been suggested as tools for stroke rehabilitation. Some initial successes have been achieved with this approach, however the mechanism by which they work is not yet fully understood. One possible part of this mechanism is a, previously suggested, relationship between the strength of the event-related desynchronization (ERD), a neural correlate of motor imagination and execution, and corticospinal excitability. Additionally, a key component of BCIs used in neurorehabilitation is the provision of visual feedback to positively reinforce attempts at motor control. However, the ability of visual feedback of the ERD to modulate the activity in the motor system has not been fully explored. Approach. We investigate these relationships via transcranial magnetic stimulation delivered at different moments in the ongoing ERD related to hand contraction and relaxation during BCI control of a visual feedback bar. Main results. We identify a significant relationship between ERD strength and corticospinal excitability, and find that our visual feedback does not affect corticospinal excitability. Significance. Our results imply that efforts to promote functional recovery in stroke by targeting increases in corticospinal excitability may be aided by accounting for the time course of the ERD.

  18. Timely event-related synchronization fading and phase de-locking and their defects in migraine.

    Science.gov (United States)

    Yum, Myung-Kul; Moon, Jin-Hwa; Kang, Joong Koo; Kwon, Oh-Young; Park, Ki-Jong; Shon, Young-Min; Lee, Il Keun; Jung, Ki-Young

    2014-07-01

    To investigate the characteristics of event-related synchronization (ERS) fading and phase de-locking of alpha waves during passive auditory stimulation (PAS) in the migraine patients. The subjects were 16 adult women with migraine and 16 normal controls. Electroencephalographic (EEG) data obtained during PAS with standard (SS) and deviant stimuli (DS) were used. Alpha ERS fading, the phase locking index (PLI) and de-locking index (DLI) were evaluated from the 10 Hz complex Morlet wavelet components at 100 ms (t100) and 300 ms (t300) after PAS. At t100, significant ERS was found with SS and DS in the migraineurs and controls (P=0.000). At t300 in the controls, ERS faded to zero for DS while in the migraineurs there was no fading for DS. In both groups the PLI for SS and DS was significantly reduced, i.e. de-locked, at t300 compared to t100 (P=0.000). In the migraineurs, the DLI for DS was significantly lower than in the controls (P=0.003). The alpha ERS fading and phase de-locking are defective in migraineurs during passive auditory cognitive processing. The defects in timely alpha ERS fading and in de-locking may play a role in the different attention processing in migraine patients. Copyright © 2013 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  19. Relationship between early and late stages of information processing: an event-related potential study

    Directory of Open Access Journals (Sweden)

    Claudio Portella

    2012-11-01

    Full Text Available The brain is capable of elaborating and executing different stages of information processing. However, exactly how these stages are processed in the brain remains largely unknown. This study aimed to analyze the possible correlation between early and late stages of information processing by assessing the latency to, and amplitude of, early and late event-related potential (ERP components, including P200, N200, premotor potential (PMP and P300, in healthy participants in the context of a visual oddball paradigm. We found a moderate positive correlation among the latency of P200 (electrode O2, N200 (electrode O2, PMP (electrode C3, P300 (electrode PZ and the reaction time (RT. In addition, moderate negative correlation between the amplitude of P200 and the latencies of N200 (electrode O2, PMP (electrode C3, P300 (electrode PZ was found. Therefore, we propose that if the secondary processing of visual input (P200 latency occurs faster, the following will also happen sooner: discrimination and classification process of this input (N200 latency, motor response processing (PMP latency, reorganization of attention and working memory update (P300 latency, and RT. N200, PMP, and P300 latencies are also anticipated when higher activation level of occipital areas involved in the secondary processing of visual input rise (P200 amplitude.

  20. Sex differences in face gender recognition: an event-related potential study.

    Science.gov (United States)

    Sun, Yueting; Gao, Xiaochao; Han, Shihui

    2010-04-23

    Multiple level neurocognitive processes are involved in face processing in humans. The present study examined whether the early face processing such as structural encoding is modulated by task demands that manipulate attention to perceptual or social features of faces and such an effect, if any, is different between men and women. Event-related brain potentials were recorded from male and female adults while they identified a low-level perceptual feature of faces (i.e., face orientation) and a high-level social feature of faces (i.e., gender). We found that task demands that required the processing of face orientations or face gender resulted in modulations of both the early occipital/temporal negativity (N170) and the late central/parietal positivity (P3). The N170 amplitude was smaller in the gender relative to the orientation identification task whereas the P3 amplitude was larger in the gender identification task relative to the orientation identification task. In addition, these effects were much stronger in women than in men. Our findings suggest that attention to social information in faces such as gender modulates both the early encoding of facial structures and late evaluative process of faces to a greater degree in women than in men.

  1. Convolutional neural networks for event-related potential detection: impact of the architecture.

    Science.gov (United States)

    Cecotti, H

    2017-07-01

    The detection of brain responses at the single-trial level in the electroencephalogram (EEG) such as event-related potentials (ERPs) is a difficult problem that requires different processing steps to extract relevant discriminant features. While most of the signal and classification techniques for the detection of brain responses are based on linear algebra, different pattern recognition techniques such as convolutional neural network (CNN), as a type of deep learning technique, have shown some interests as they are able to process the signal after limited pre-processing. In this study, we propose to investigate the performance of CNNs in relation of their architecture and in relation to how they are evaluated: a single system for each subject, or a system for all the subjects. More particularly, we want to address the change of performance that can be observed between specifying a neural network to a subject, or by considering a neural network for a group of subjects, taking advantage of a larger number of trials from different subjects. The results support the conclusion that a convolutional neural network trained on different subjects can lead to an AUC above 0.9 by using an appropriate architecture using spatial filtering and shift invariant layers.

  2. Clinical usefulness and feasibility of time-frequency analysis of chemosensory event-related potentials.

    Science.gov (United States)

    Huart, C; Rombaux, Ph; Hummel, T; Mouraux, A

    2013-09-01

    The clinical usefulness of olfactory event-related brain potentials (OERPs) to assess olfactory function is limited by the relatively low signal-to-noise ratio of the responses identified using conventional time-domain averaging. Recently, it was shown that time-frequency analysis of the obtained EEG signals can markedly improve the signal-to-noise ratio of OERPs in healthy controls, because it enhances both phase-locked and non phase-locked EEG responses. The aim of the present study was to investigate the clinical usefulness of this approach and evaluate its feasibility in a clinical setting. We retrospectively analysed EEG recordings obtained from 45 patients (15 anosmic, 15 hyposmic and 15 normos- mic). The responses to olfactory stimulation were analysed using conventional time-domain analysis and joint time-frequency analysis. The ability of the two methods to discriminate between anosmic, hyposmic and normosmic patients was assessed using a Receiver Operating Characteristic analysis. The discrimination performance of OERPs identified using conventional time-domain averaging was poor. In contrast, the discrimination performance of the EEG response identified in the time-frequency domain was relatively high. Furthermore, we found a significant correlation between the magnitude of this response and the psychophysical olfactory score. Time-frequency analysis of the EEG responses to olfactory stimulation could be used as an effective and reliable diagnostic tool for the objective clinical evaluation of olfactory function in patients.

  3. The esthetic preference of Chinese typefaces--an event-related potential study.

    Science.gov (United States)

    Li, Rui; Qin, Ruilin; Zhang, Junsong; Wu, Junjie; Zhou, Changle

    2015-02-19

    Emotional stimuli such as pictures, logos, geometric shapes, etc can evoke human esthetic preference from previous neuroesthetic studies. Chinese characters can be considered as emotional stimuli as they have an important property: typeface. Intuitively, the emotional meaning of Chinese characters can cause esthetic preference. However, whether a typeface can cause esthetic preference or not from an empirical perspective is still unknown. To address this issue, participants׳ event-related potential (ERP) waves are recorded while they are presented a series of Chinese characters in different typefaces. Participants are asked to distinguish specific target from the others. Afterwards, from the Chinese characters presented in this task, participants are asked individually to select the characters they like the most and dislike the most. By recording the ERP responses (a response of implicit preference to Chinese characters themselves) during the experiment to different typefaces of Chinese characters, we find a significant difference between disliked and all characters in the frontal-central area in the 200-300 ms window after the stimulus׳ onset. In the 400-600 ms window, after the stimulus׳ onset, a significant bias for disliked characters emerges in frontal, central, parietal and occipital areas. Our results suggest that people could make a rapid, implicit esthetic preference for the typefaces of Chinese characters. Copyright © 2014. Published by Elsevier B.V.

  4. Mastication accelerates Go/No-go decisional processing: An event-related potential study.

    Science.gov (United States)

    Sakamoto, Kiwako; Nakata, Hiroki; Yumoto, Masato; Sadato, Norihiro; Kakigi, Ryusuke

    2015-11-01

    The purpose of the present study was to investigate the effect of mastication on Go/No-go decisional processing using event-related potentials (ERPs). Thirteen normal subjects underwent seven sessions of a somatosensory Go/No-go paradigm for approximately 4min; Pre, and Post 1, 2, 3, 4, 5, and 6. The Control condition included the same seven sessions. The RT and standard deviation were recorded, and the peak amplitude and latency of the N140 and P300 components were analyzed. The RT was significantly shorter in Mastication than in Control at Post 1-3 and 4-6. The peak latency of N140 was earlier in Mastication than in Control at Post 4-6. The latency of N140 was shortened by repeated sessions in Mastication, but not by those in Control. The peak latency of P300 was significantly shorter in Mastication than in Control at Post 4-6. The peak latency of P300 was significantly longer in Control with repeated sessions, but not in Mastication. These results suggest that mastication may influence response execution processing in Go trials, as well as response inhibition processing in No-go trials. Mastication accelerated Go/No-go decisional processing in the human brain. Copyright © 2015 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  5. Rejection in Bargaining Situations: An Event-Related Potential Study in Adolescents and Adults.

    Directory of Open Access Journals (Sweden)

    Kiki Zanolie

    Full Text Available The neural correlates of rejection in bargaining situations when proposing a fair or unfair offer are not yet well understood. We measured neural responses to rejection and acceptance of monetary offers with event-related potentials (ERPs in mid-adolescents (14-17 years and early adults (19-24 years. Participants played multiple rounds of the Ultimatum Game as proposers, dividing coins between themselves and a second player (responder by making a choice between an unfair distribution (7 coins for proposer and 3 for responder; 7/3 and one of two alternatives: a fair distribution (5/5 or a hyperfair distribution (3/7. Participants mostly made fair offers (5/5 when the alternative was unfair (7/3, but made mostly unfair offers (7/3 when the alternative was hyperfair (3/7. When participants' fair offers (5/5; alternative was 7/3 were rejected this was associated with a larger Medial Frontal Negativity (MFN compared to acceptance of fair offers and rejection of unfair offers (7/3; alternative was 3/7. Also, the MFN was smaller after acceptance of unfair offers (7/3 compared to rejection. These neural responses did not differ between adults and mid-adolescents, suggesting that the MFN reacts as a neural alarm system to social prediction errors which is already prevalent during adolescence.

  6. Neurophysiological traces of interpersonal pain: How emotional autobiographical memories affect event-related potentials.

    Science.gov (United States)

    Rohde, Kristina B; Caspar, Franz; Koenig, Thomas; Pascual-Leone, Antonio; Stein, Maria

    2018-03-01

    The automatic, involuntary reactivation of disturbing emotional memories, for example, of interpersonal pain, causes psychological discomfort and is central to many psychopathologies. This study aimed at elucidating the automatic brain processes underlying emotional autobiographical memories by investigating the neurophysiological dynamics within the first second after memory reactivation. Pictures of different individualized familiar faces served as cues for different specific emotional autobiographical memories, for example, for memories of interpersonal pain and grievances or for memories of appreciation in interpersonal relationships. Nineteen subjects participated in a passive face-viewing task while multichannel electroencephalogram was recorded. Analyses of event-related potentials demonstrated that emotional memories elicited an early posterior negativity and a stronger late positive potential, which tended to be particularly enhanced for painful memories. Source estimations attributed this stronger activation to networks including the posterior cingulate and ventrolateral prefrontal cortices. The findings suggest that the reactivation of emotional autobiographical memories involves privileged automatic attention at perceptual processing stages, and an enhanced recruitment of neural network activity at a postperceptual stage sensitive to emotional-motivational processing. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  7. Time-Frequency Data Reduction for Event Related Potentials: Combining Principal Component Analysis and Matching Pursuit

    Directory of Open Access Journals (Sweden)

    Selin Aviyente

    2010-01-01

    Full Text Available Joint time-frequency representations offer a rich representation of event related potentials (ERPs that cannot be obtained through individual time or frequency domain analysis. This representation, however, comes at the expense of increased data volume and the difficulty of interpreting the resulting representations. Therefore, methods that can reduce the large amount of time-frequency data to experimentally relevant components are essential. In this paper, we present a method that reduces the large volume of ERP time-frequency data into a few significant time-frequency parameters. The proposed method is based on applying the widely used matching pursuit (MP approach, with a Gabor dictionary, to principal components extracted from the time-frequency domain. The proposed PCA-Gabor decomposition is compared with other time-frequency data reduction methods such as the time-frequency PCA approach alone and standard matching pursuit methods using a Gabor dictionary for both simulated and biological data. The results show that the proposed PCA-Gabor approach performs better than either the PCA alone or the standard MP data reduction methods, by using the smallest amount of ERP data variance to produce the strongest statistical separation between experimental conditions.

  8. Event-related fields evoked by vocal response inhibition: a comparison of younger and older adults.

    Science.gov (United States)

    Castro-Meneses, Leidy J; Johnson, Blake W; Sowman, Paul F

    2016-06-01

    The current study examined event-related fields (ERFs) evoked by vocal response inhibition in a stimulus-selective stop-signal task. We compared inhibition-related ERFs across a younger and an older group of adults. Behavioural results revealed that stop-signal reaction times (RTs), go-RTs, ignore-stop RTs and failed stop RTs were longer in the older, relative to the younger group by 38, 123, 149 and 116 ms, respectively. The amplitude of the ERF M2 peak (approximately 200 ms after the stop signal) evoked on successful stop trials was larger compared to that evoked on both failed stop and ignore-stop trials. The M4 peak (approximately 450 ms after stop signal) was of larger amplitude in both successful and failed stops compared to ignore-stop trials. In the older group, the M2, M3 and M4 peaks were smaller in amplitude and peaked later in time (by 24, 50 and 76 ms, respectively). We demonstrate that vocal response inhibition-related ERFs exhibit a similar temporal evolution to those previously described for manual response inhibition: an early peak at 200 ms (i.e. M2) that differentiates successful from failed stopping, and a later peak (i.e. M4) that is consistent with a neural marker of response checking and error processing. Across groups, our data support a more general decline of stimulus processing speed with age.

  9. Attention to affective pictures in closed head injury: event-related brain potentials and cardiac responses.

    Science.gov (United States)

    Solbakk, Anne-Kristin; Reinvang, Ivar; Svebak, Sven; Nielsen, Christopher S; Sundet, Kjetil

    2005-02-01

    We examined whether closed head injury patients show altered patterns of selective attention to stimulus categories that naturally evoke differential responses in healthy people. Self-reported rating and electrophysiological (event-related potentials [ERPs], heart rate [HR]) responses to affective pictures were studied in patients with mild head injury (n = 20; CT/MRI negative), in patients with predominantly frontal brain lesions (n = 12; CT/MRI confirmed), and in healthy controls (n = 20). Affective valence similarly modulated HR and ERP responses in all groups, but group differences occurred that were independent of picture valence. The attenuation of P3-slow wave amplitudes in the mild head injury group indicates a reduction in the engagement of attentional resources to the task. In contrast, the general enhancement of ERP amplitudes at occipital sites in the group with primarily frontal brain injury may reflect disinhibition of input at sensory receptive areas, possibly due to a deficit in top-down modulation performed by anterior control systems.

  10. Emotional event-related potentials are reduced if negative pictures presented at fixation are unattended.

    Science.gov (United States)

    Wiens, Stefan; Sand, Anders; Norberg, Joakim; Andersson, Per

    2011-05-20

    Viewing of emotional pictures elicits two event-related potentials (ERPs) to emotional versus neutral pictures: an early posterior negativity (EPN) and a late positive potential (LPP). Because it is unresolved whether these indexes of emotional processing are reduced to task-irrelevant pictures at fixation, negative and neutral pictures from the International Affective Picture Set (IAPS) were shown at fixation together with 6 letters that surrounded the pictures. In separate tasks, participants were instructed to attend either the pictures or the letters. When the pictures were task relevant, results showed an EPN and LPP. In contrast, when the pictures were task irrelevant, the EPN was eliminated and the LPP reduced. Performance was high in both tasks (hit rates>87%), but somewhat better when the pictures were relevant. However, analyses showed no relationship between this performance difference and the differences in EPN and LPP between tasks. These results suggest that emotional processing of strong, negative pictures is sensitive to manipulations of attention even if the pictures are shown at fixation. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  11. Latency correction of event-related potentials between different experimental protocols

    Science.gov (United States)

    Iturrate, I.; Chavarriaga, R.; Montesano, L.; Minguez, J.; Millán, JdR

    2014-06-01

    Objective. A fundamental issue in EEG event-related potentials (ERPs) studies is the amount of data required to have an accurate ERP model. This also impacts the time required to train a classifier for a brain-computer interface (BCI). This issue is mainly due to the poor signal-to-noise ratio and the large fluctuations of the EEG caused by several sources of variability. One of these sources is directly related to the experimental protocol or application designed, and may affect the amplitude or latency of ERPs. This usually prevents BCI classifiers from generalizing among different experimental protocols. In this paper, we analyze the effect of the amplitude and the latency variations among different experimental protocols based on the same type of ERP. Approach. We present a method to analyze and compensate for the latency variations in BCI applications. The algorithm has been tested on two widely used ERPs (P300 and observation error potentials), in three experimental protocols in each case. We report the ERP analysis and single-trial classification. Main results. The results obtained show that the designed experimental protocols significantly affect the latency of the recorded potentials but not the amplitudes. Significance. These results show how the use of latency-corrected data can be used to generalize the BCIs, reducing the calibration time when facing a new experimental protocol.

  12. Sociality Mental Modes Modulate the Processing of Advice-Giving: An Event-Related Potentials Study

    Directory of Open Access Journals (Sweden)

    Jin Li

    2018-02-01

    Full Text Available People have different motivations to get along with others in different sociality mental modes (i.e., communal mode and market mode, which might affect social decision-making. The present study examined how these two types of sociality mental modes affect the processing of advice-giving using the event-related potentials (ERPs. After primed with the communal mode and market mode, participants were instructed to decide whether or not give an advice (profitable or damnous to a stranger without any feedback. The behavioral results showed that participants preferred to give the profitable advice to the stranger more slowly compared with the damnous advice, but this difference was only observed in the market mode condition. The ERP results indicated that participants demonstrated more negative N1 amplitude for the damnous advice compared with the profitable advice, and larger P300 was elicited in the market mode relative to both the communal mode and the control group. More importantly, participants in the market mode demonstrated larger P300 for the profitable advice than the damnous advice, whereas this difference was not observed at the communal mode and the control group. These findings are consistent with the dual-process system during decision-making and suggest that market mode may lead to deliberate calculation for costs and benefits when giving the profitable advice to others.

  13. The impact of emotional involvement on online service buying decisions: an event-related potentials perspective.

    Science.gov (United States)

    Zhao, Meina; Wang, Jing; Han, Weiwei

    2015-12-02

    When examining a buying process, changes in human brain signals and their event-related potential (ERP) components can be considered a reflection of the consumers' emotions. In this experiment, participants were shown 12 products and related services that were available for purchase. After recording ERP components, we used a questionnaire to measure the individuals' emotional involvement toward the services (i.e. the same services shown in the stimuli) of the 12 products to measure the emotional valence of the services. The emotional ERP components and the late positive potential (LPP) were elicited under the service conditions and distributed over the left frontal regions. We determined that the services may evoke an LPP and that services with a high emotional value may evoke a larger LPP, which suggests that positive emotion may be measured using the LPP amplitude in the left frontal regions. This result helps elucidate whether positive emotions are stimulated during the product-service system decision-making process and helps understand the emotional valences of different services. Our analysis of the emotional motivation of the consumer suggests that the LPP may be useful as an emotional indicator for measuring consumers' evaluation of services that provides a neural view of product-service system buying decisions.

  14. Olfactory short-term memory encoding and maintenance - an event-related potential study.

    Science.gov (United States)

    Lenk, Steffen; Bluschke, Annet; Beste, Christian; Iannilli, Emilia; Rößner, Veit; Hummel, Thomas; Bender, Stephan

    2014-09-01

    This study examined whether the memory encoding and short term maintenance of olfactory stimuli is associated with neurophysiological activation patterns which parallel those described for sensory modalities such as vision and auditory. We examined olfactory event-related potentials in an olfactory change detection task in twenty-four healthy adults and compared the measured activation to that found during passive olfactory stimulation. During the early olfactory post-processing phase, we found a sustained negativity over bilateral frontotemporal areas in the passive perception condition which was enhanced in the active memory task. There was no significant lateralization in either experimental condition. During the maintenance interval at the end of the delay period, we still found sustained activation over bilateral frontotemporal areas which was more negative in trials with correct - as compared to incorrect - behavioural responses. This was complemented by a general significantly stronger frontocentral activation. Summarizing, we were able to show that olfactory short term memory involves a parallel sequence of activation as found in other sensory modalities. In addition to olfactory-specific frontotemporal activations in the memory encoding phase, we found slow cortical potentials over frontocentral areas during the memory maintenance phase indicating the activation of a supramodal memory maintenance system. These findings could represent the neurophysiological underpinning of the 'olfactory flacon', the olfactory counter-part to the visual sketchpad and phonological loop embedded in Baddeley's working memory model. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. Association between waking electroencephalography and cognitive event-related potentials in patients with obstructive sleep apnea.

    Science.gov (United States)

    Baril, Andrée-Ann; Gagnon, Katia; Gagnon, Jean-François; Montplaisir, Jacques; Gosselin, Nadia

    2013-07-01

    Sleepiness, cognitive deficits, abnormal event-related potentials (ERP), and slowing of the waking electroencephalography (EEG) activity have been reported in patients with obstructive sleep apnea (OSA). Our study aimed at evaluating if an association exists between the severity of ERP abnormalities and EEG slowing to better understand cerebral dysfunctions in OSA. Twelve OSA patients and 12 age-matched controls underwent an overnight polysomnographic recording, an EEG recording of 10 min of wakefulness, and an auditory ERP protocol known to specifically recruit attention. P300 and P3a ERP components were measured as well as the spectral power in each frequency band of the waking EEG. Pearson product moment correlations were used to measure associations between ERP characteristics and EEG spectral power in OSA patients and control subjects. A positive correlation between the late P300 amplitude and θ power in the occipital region was observed in OSA subjects (P<.01). A positive correlation was also found between P3a amplitude and β1 power in central region in OSA subjects (P<.01). No correlation was observed for control subjects. ERP abnormalities observed in an attention task are associated with a slowing of the waking EEG recorded at rest in OSA. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Single-Trial Event-Related Potential Based Rapid Image Triage System

    Directory of Open Access Journals (Sweden)

    Ke Yu

    2011-06-01

    Full Text Available Searching for points of interest (POI in large-volume imagery is a challenging problem with few good solutions. In this work, a neural engineering approach called rapid image triage (RIT which could offer about a ten-fold speed up in POI searching is developed. It is essentially a cortically-coupled computer vision technique, whereby the user is presented bursts of images at a speed of 6–15 images per second and then neural signals called event-related potential (ERP is used as the ‘cue’ for user seeing images of high relevance likelihood. Compared to past efforts, the implemented system has several unique features: (1 it applies overlapping frames in image chip preparation, to ensure rapid image triage performance; (2 a novel common spatial-temporal pattern (CSTP algorithm that makes use of both spatial and temporal patterns of ERP topography is proposed for high-accuracy single-trial ERP detection; (3 a weighted version of probabilistic support-vector-machine (SVM is used to address the inherent unbalanced nature of single-trial ERP detection for RIT. High accuracy, fast learning, and real-time capability of the developed system shown on 20 subjects demonstrate the feasibility of a brainmachine integrated rapid image triage system for fast detection of POI from large-volume imagery.

  17. Aesthetic appreciation of poetry correlates with ease of processing in event-related potentials.

    Science.gov (United States)

    Obermeier, Christian; Kotz, Sonja A; Jessen, Sarah; Raettig, Tim; von Koppenfels, Martin; Menninghaus, Winfried

    2016-04-01

    Rhetorical theory suggests that rhythmic and metrical features of language substantially contribute to persuading, moving, and pleasing an audience. A potential explanation of these effects is offered by "cognitive fluency theory," which stipulates that recurring patterns (e.g., meter) enhance perceptual fluency and can lead to greater aesthetic appreciation. In this article, we explore these two assertions by investigating the effects of meter and rhyme in the reception of poetry by means of event-related brain potentials (ERPs). Participants listened to four versions of lyrical stanzas that varied in terms of meter and rhyme, and rated the stanzas for rhythmicity and aesthetic liking. The behavioral and ERP results were in accord with enhanced liking and rhythmicity ratings for metered and rhyming stanzas. The metered and rhyming stanzas elicited smaller N400/P600 ERP responses than their nonmetered, nonrhyming, or nonmetered and nonrhyming counterparts. In addition, the N400 and P600 effects for the lyrical stanzas correlated with aesthetic liking effects (metered-nonmetered), implying that modulation of the N400 and P600 has a direct bearing on the aesthetic appreciation of lyrical stanzas. We suggest that these effects are indicative of perceptual-fluency-enhanced aesthetic liking, as postulated by cognitive fluency theory.

  18. Visual event-related potentials to biological motion stimuli in autism spectrum disorders

    Science.gov (United States)

    Bletsch, Anke; Krick, Christoph; Siniatchkin, Michael; Jarczok, Tomasz A.; Freitag, Christine M.; Bender, Stephan

    2014-01-01

    Atypical visual processing of biological motion contributes to social impairments in autism spectrum disorders (ASD). However, the exact temporal sequence of deficits of cortical biological motion processing in ASD has not been studied to date. We used 64-channel electroencephalography to study event-related potentials associated with human motion perception in 17 children and adolescents with ASD and 21 typical controls. A spatio-temporal source analysis was performed to assess the brain structures involved in these processes. We expected altered activity already during early stimulus processing and reduced activity during subsequent biological motion specific processes in ASD. In response to both, random and biological motion, the P100 amplitude was decreased suggesting unspecific deficits in visual processing, and the occipito-temporal N200 showed atypical lateralization in ASD suggesting altered hemispheric specialization. A slow positive deflection after 400 ms, reflecting top-down processes, and human motion-specific dipole activation differed slightly between groups, with reduced and more diffuse activation in the ASD-group. The latter could be an indicator of a disrupted neuronal network for biological motion processing in ADS. Furthermore, early visual processing (P100) seems to be correlated to biological motion-specific activation. This emphasizes the relevance of early sensory processing for higher order processing deficits in ASD. PMID:23887808

  19. Emotional processing and psychopathic traits in male college students: An event-related potential study.

    Science.gov (United States)

    Medina, Amy L; Kirilko, Elvira; Grose-Fifer, Jillian

    2016-08-01

    Emotional processing deficits are often considered a hallmark of psychopathy. However, there are relatively few studies that have investigated how the late positive potential (LPP) elicited by both positive and negative emotional stimuli is modulated by psychopathic traits, especially in undergraduates. Attentional deficits have also been posited to be associated with emotional blunting in psychopathy, consequently, results from previous studies may have been influenced by task demands. Therefore, we investigated the relationship between the neural correlates of emotional processing and psychopathic traits by measuring event-related potentials (ERPs) during a task with a relatively low cognitive load. A group of male undergraduates were classified as having either high or low levels of psychopathic traits according to their total scores on the Psychopathic Personality Inventory - Revised (PPI-R). A subgroup of these participants then passively viewed complex emotional and neutral images from the International Affective Picture System (IAPS) while their EEGs were recorded. As hypothesized, in general the late LPP elicited by emotional pictures was found to be significantly reduced for participants with high Total PPI-R scores relative to those with low scores, especially for pictures that were rated as less emotionally arousing. Our data suggest that male undergraduates with high, but subclinical levels of psychopathic traits did not maintain continued higher-order processing of affective information, especially when it was perceived to be less arousing in nature. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Test-retest reliability of infant event related potentials evoked by faces.

    Science.gov (United States)

    Munsters, N M; van Ravenswaaij, H; van den Boomen, C; Kemner, C

    2017-04-05

    Reliable measures are required to draw meaningful conclusions regarding developmental changes in longitudinal studies. Little is known, however, about the test-retest reliability of face-sensitive event related potentials (ERPs), a frequently used neural measure in infants. The aim of the current study is to investigate the test-retest reliability of ERPs typically evoked by faces in 9-10 month-old infants. The infants (N=31) were presented with neutral, fearful and happy faces that contained only the lower or higher spatial frequency information. They were tested twice within two weeks. The present results show that the test-retest reliability of the face-sensitive ERP components is moderate (P400 and Nc) to substantial (N290). However, there is low test-retest reliability for the effects of the specific experimental manipulations (i.e. emotion and spatial frequency) on the face-sensitive ERPs. To conclude, in infants the face-sensitive ERP components (i.e. N290, P400 and Nc) show adequate test-retest reliability, but not the effects of emotion and spatial frequency on these ERP components. We propose that further research focuses on investigating elements that might increase the test-retest reliability, as adequate test-retest reliability is necessary to draw meaningful conclusions on individual developmental trajectories of the face-sensitive ERPs in infants. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  1. Event-related potential correlates of emergent inference in human arbitrary relational learning.

    Science.gov (United States)

    Wang, Ting; Dymond, Simon

    2013-01-01

    Two experiments investigated the functional-anatomical correlates of cognition supporting untrained, emergent relational inference in a stimulus equivalence task. In Experiment 1, after learning a series of conditional relations involving words and pseudowords, participants performed a relatedness task during which EEG was recorded. Behavioural performance was faster and more accurate on untrained, indirectly related symmetry (i.e., learn AB and infer BA) and equivalence trials (i.e., learn AB and AC and infer CB) than on unrelated trials, regardless of whether or not a formal test for stimulus equivalence relations had been conducted. Consistent with previous results, event related potentials (ERPs) evoked by trained and emergent trials at parietal and occipital sites differed only for those participants who had not received a prior equivalence test. Experiment 2 further replicated and extended these behavioural and ERP findings using arbitrary symbols as stimuli and demonstrated time and frequency differences for trained and untrained relatedness trials. Overall, the findings demonstrate convincingly the ERP correlates of intra-experimentally established stimulus equivalence relations consisting entirely of arbitrary symbols and offer support for a contemporary cognitive-behavioural model of symbolic categorisation and relational inference. Copyright © 2012 Elsevier B.V. All rights reserved.

  2. The light-makeup advantage in facial processing: Evidence from event-related potentials.

    Science.gov (United States)

    Tagai, Keiko; Shimakura, Hitomi; Isobe, Hiroko; Nittono, Hiroshi

    2017-01-01

    The effects of makeup on attractiveness have been evaluated using mainly subjective measures. In this study, event-related brain potentials (ERPs) were recorded from a total of 45 Japanese women (n = 23 and n = 22 for Experiment 1 and 2, respectively) to examine the neural processing of faces with no makeup, light makeup, and heavy makeup. To have the participants look at each face carefully, an identity judgement task was used: they were asked to judge whether the two faces presented in succession were of the same person or not. The ERP waveforms in response to the first faces were analyzed. In two experiments with different stimulus probabilities, the amplitudes of N170 and vertex positive potential (VPP) were smaller for faces with light makeup than for faces with heavy makeup or no makeup. The P1 amplitude did not differ between facial types. In a subsequent rating phase, faces with light makeup were rated as more attractive than faces with heavy makeup and no makeup. The results suggest that the processing fluency of faces with light makeup is one of the reasons why light makeup is preferred to heavy makeup and no makeup in daily life.

  3. Tracking cognitive phases in analogical reasoning with event-related potentials.

    Science.gov (United States)

    Maguire, Mandy J; McClelland, M Michelle; Donovan, Colin M; Tillman, Gail D; Krawczyk, Daniel C

    2012-03-01

    Analogical reasoning consists of multiple phases. Four-term analogies (A:B::C:D) have an encoding period in which the A:B pair is evaluated prior to a mapping phase. The electrophysiological timing associated with analogical reasoning has remained unclear. We used event-related potentials to identify neural timing related to analogical reasoning relative to perceptual and semantic control conditions. Spatiotemporal principal-components analyses revealed differences primarily in left frontal electrodes during encoding and mapping phases of analogies relative to the other conditions. The timing of the activity differed depending upon the phase of the problem. During the encoding of A:B terms, analogies elicited a positive deflection compared to the control conditions between 400 and 1,200 ms, but for the mapping phase analogical processing elicited a negative deflection that occurred earlier and for a shorter time period, between 350 and 625 ms. These results provide neural and behavioral evidence that 4-term analogy problems involve a highly active evaluation phase of the A:B pair. 2012 APA, all rights reserved

  4. Relating derived relations as a model of analogical reasoning: reaction times and event-related potentials.

    Science.gov (United States)

    Barnes-Holmes, Dermot; Regan, Donal; Barnes-Holmes, Yvonne; Commins, Sean; Walsh, Derek; Stewart, Ian; Smeets, Paul M; Whelan, Robert; Dymond, Simon

    2005-11-01

    The current study aimed to test a Relational Frame Theory (RFT) model of analogical reasoning based on the relating of derived same and derived difference relations. Experiment 1 recorded reaction time measures of similar-similar (e.g., "apple is to orange as dog is to cat") versus different-different (e.g., "he is to his brother as chalk is to cheese") derived relational responding, in both speed-contingent and speed-noncontingent conditions. Experiment 2 examined the event-related potentials (ERPs) associated with these two response patterns. Both experiments showed similar-similar responding to be significantly faster than different-different responding. Experiment 2 revealed significant differences between the waveforms of the two response patterns in the left-hemispheric prefrontal regions; different-different waveforms were significantly more negative than similar-similar waveforms. The behavioral and neurophysiological data support the RFT prediction that, all things being equal, similar-similar responding is relationally "simpler" than, and functionally distinct from, different-different analogical responding. The ERP data were fully consistent with findings in the neurocognitive literature on analogy. These findings strengthen the validity of the RFT model of analogical reasoning and supplement the behavior-analytic approach to analogy based on the relating of derived relations.

  5. Altered processing of visual emotional stimuli in posttraumatic stress disorder: an event-related potential study.

    Science.gov (United States)

    Saar-Ashkenazy, Rotem; Shalev, Hadar; Kanthak, Magdalena K; Guez, Jonathan; Friedman, Alon; Cohen, Jonathan E

    2015-08-30

    Patients with posttraumatic stress disorder (PTSD) display abnormal emotional processing and bias towards emotional content. Most neurophysiological studies in PTSD found higher amplitudes of event-related potentials (ERPs) in response to trauma-related visual content. Here we aimed to characterize brain electrical activity in PTSD subjects in response to non-trauma-related emotion-laden pictures (positive, neutral and negative). A combined behavioral-ERP study was conducted in 14 severe PTSD patients and 14 controls. Response time in PTSD patients was slower compared with that in controls, irrespective to emotional valence. In both PTSD and controls, response time to negative pictures was slower compared with that to neutral or positive pictures. Upon ranking, both control and PTSD subjects similarly discriminated between pictures with different emotional valences. ERP analysis revealed three distinctive components (at ~300, ~600 and ~1000 ms post-stimulus onset) for emotional valence in control subjects. In contrast, PTSD patients displayed a similar brain response across all emotional categories, resembling the response of controls to negative stimuli. We interpret these findings as a brain-circuit response tendency towards negative overgeneralization in PTSD. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  6. Interactions between mood and the structure of semantic memory: event-related potentials evidence.

    Science.gov (United States)

    Pinheiro, Ana P; del Re, Elisabetta; Nestor, Paul G; McCarley, Robert W; Gonçalves, Óscar F; Niznikiewicz, Margaret

    2013-06-01

    Recent evidence suggests that affect acts as modulator of cognitive processes and in particular that induced mood has an effect on the way semantic memory is used on-line. We used event-related potentials (ERPs) to examine affective modulation of semantic information processing under three different moods: neutral, positive and negative. Fifteen subjects read 324 pairs of sentences, after mood induction procedure with 30 pictures of neutral, 30 pictures of positive and 30 pictures of neutral valence: 108 sentences were read in each mood induction condition. Sentences ended with three word types: expected words, within-category violations, and between-category violations. N400 amplitude was measured to the three word types under each mood induction condition. Under neutral mood, a congruency (more negative N400 amplitude for unexpected relative to expected endings) and a category effect (more negative N400 amplitude for between- than to within-category violations) were observed. Also, results showed differences in N400 amplitude for both within- and between-category violations as a function of mood: while positive mood tended to facilitate the integration of unexpected but related items, negative mood made their integration as difficult as unexpected and unrelated items. These findings suggest the differential impact of mood on access to long-term semantic memory during sentence comprehension.

  7. Specific neural basis of Chinese idioms processing: an event-related functional MRI study

    International Nuclear Information System (INIS)

    Chen Shaoqi; Zhang Yanzhen; Xiao Zhuangwei; Zhang Xuexin

    2007-01-01

    Objective: To address the neural basis of Chinese idioms processing with different kinds of stimuli using an event-related fMRI design. Methods: Sixteen native Chinese speakers were asked to perform a semantic decision task during fMRI scanning. Three kinds of stimuli were used: Real idioms (Real-idiom condition); Literally plausible phrases (Pseudo-idiom condition, the last character of a real idiom was replaced by a character with similar meaning); Literally implausible strings (Non-idiom condition, the last character of a real idiom was replaced by a character with unrelated meaning). Reaction time and correct rate were recorded at the same time. Results: The error rate was 2.6%, 5.2% and 0.9% (F=3.51, P 0.05) for real idioms, pseudo-idioms and wrong idioms, respectively. Similar neural network was activated in all of the three conditions. However, the right hippocampus was only activated in the real idiom condition, and significant activations were found in anterior portion of left inferior frontal gyms (BA47) in real-and pseudo-idiom conditions, but not in non-idiom condition. Conclusion: The right hippocampus plays a specific role in the particular wording of the Chinese idioms. And the left anterior inferior frontal gyms (BA47) may be engaged in the semantic processing of Chinese idioms. The results support the notion that there were specific neural bases for Chinese idioms processing. (authors)

  8. Event-related brain responses to emotional words, pictures, and faces - a cross-domain comparison.

    Science.gov (United States)

    Bayer, Mareike; Schacht, Annekathrin

    2014-01-01

    Emotion effects in event-related brain potentials (ERPs) have previously been reported for a range of visual stimuli, including emotional words, pictures, and facial expressions. Still, little is known about the actual comparability of emotion effects across these stimulus classes. The present study aimed to fill this gap by investigating emotion effects in response to words, pictures, and facial expressions using a blocked within-subject design. Furthermore, ratings of stimulus arousal and valence were collected from an independent sample of participants. Modulations of early posterior negativity (EPN) and late positive complex (LPC) were visible for all stimulus domains, but showed clear differences, particularly in valence processing. While emotion effects were limited to positive stimuli for words, they were predominant for negative stimuli in pictures and facial expressions. These findings corroborate the notion of a positivity offset for words and a negativity bias for pictures and facial expressions, which was assumed to be caused by generally lower arousal levels of written language. Interestingly, however, these assumed differences were not confirmed by arousal ratings. Instead, words were rated as overall more positive than pictures and facial expressions. Taken together, the present results point toward systematic differences in the processing of written words and pictorial stimuli of emotional content, not only in terms of a valence bias evident in ERPs, but also concerning their emotional evaluation captured by ratings of stimulus valence and arousal.

  9. Event-related brain potential correlates of human auditory sensory memory-trace formation.

    Science.gov (United States)

    Haenschel, Corinna; Vernon, David J; Dwivedi, Prabuddh; Gruzelier, John H; Baldeweg, Torsten

    2005-11-09

    The event-related potential (ERP) component mismatch negativity (MMN) is a neural marker of human echoic memory. MMN is elicited by deviant sounds embedded in a stream of frequent standards, reflecting the deviation from an inferred memory trace of the standard stimulus. The strength of this memory trace is thought to be proportional to the number of repetitions of the standard tone, visible as the progressive enhancement of MMN with number of repetitions (MMN memory-trace effect). However, no direct ERP correlates of the formation of echoic memory traces are currently known. This study set out to investigate changes in ERPs to different numbers of repetitions of standards, delivered in a roving-stimulus paradigm in which the frequency of the standard stimulus changed randomly between stimulus trains. Normal healthy volunteers (n = 40) were engaged in two experimental conditions: during passive listening and while actively discriminating changes in tone frequency. As predicted, MMN increased with increasing number of standards. However, this MMN memory-trace effect was caused mainly by enhancement with stimulus repetition of a slow positive wave from 50 to 250 ms poststimulus in the standard ERP, which is termed here "repetition positivity" (RP). This RP was recorded from frontocentral electrodes when participants were passively listening to or actively discriminating changes in tone frequency. RP may represent a human ERP correlate of rapid and stimulus-specific adaptation, a candidate neuronal mechanism underlying sensory memory formation in the auditory cortex.

  10. Can echoic memory store two traces simultaneously? A study of event-related brain potentials.

    Science.gov (United States)

    Winkler, I; Paavilainen, P; Näätänen, R

    1992-05-01

    The mismatch negativity, a component of the event-related brain potential elicited by infrequent deviants in sequences of auditory stimuli, is presumably generated by an automatic mismatch process in a mechanism that compares the current stimulus to the trace of the previous one. The present study addressed the possible simultaneous existence of two such traces. Two equiprobable (45% each) frequent stimuli ("standards"), one of 600 Hz and the other of 700 Hz, were presented together with an infrequent (10%), "deviant" stimulus which was of different frequency in different blocks. These deviants elicited a mismatch negativity, though a smaller one than that obtained in corresponding blocks with only one standard stimulus. Two aspects of the present results from the blocks with two standard stimuli implicate two parallel stimulus traces in these blocks: 1) deviants elicited a mismatch negativity (MMN) of approximately the same amplitude when preceded by sequences of four identical standards as when preceded by sequences of four stimuli containing both standards; 2) in contrast to the one-standard condition, the magnitude of stimulus deviance did not affect the MMN component elicited by the different deviants.

  11. Auditory event-related potentials in children with benign epilepsy with centro-temporal spikes.

    Science.gov (United States)

    Tomé, David; Sampaio, Mafalda; Mendes-Ribeiro, José; Barbosa, Fernando; Marques-Teixeira, João

    2014-12-01

    Benign focal epilepsy in childhood with centro-temporal spikes (BECTS) is one of the most common forms of idiopathic epilepsy, with onset from age 3 to 14 years. Although the prognosis for children with BECTS is excellent, some studies have revealed neuropsychological deficits in many domains, including language. Auditory event-related potentials (AERPs) reflect activation of different neuronal populations and are suggested to contribute to the evaluation of auditory discrimination (N1), attention allocation and phonological categorization (N2), and echoic memory (mismatch negativity--MMN). The scarce existing literature about this theme motivated the present study, which aims to investigate and document the existing AERP changes in a group of children with BECTS. AERPs were recorded, during the day, to pure and vocal tones and in a conventional auditory oddball paradigm in five children with BECTS (aged 8-12; mean=10 years; male=5) and in six gender and age-matched controls. Results revealed high amplitude of AERPs for the group of children with BECTS with a slight latency delay more pronounced in fronto-central electrodes. Children with BECTS may have abnormal central auditory processing, reflected by electrophysiological measures such as AERPs. In advance, AERPs seem a good tool to detect and reliably reveal cortical excitability in children with typical BECTS. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. An Event-Related Potential Study on the Effects of Cannabis on Emotion Processing

    Science.gov (United States)

    Troup, Lucy J.; Bastidas, Stephanie; Nguyen, Maia T.; Andrzejewski, Jeremy A.; Bowers, Matthew; Nomi, Jason S.

    2016-01-01

    The effect of cannabis on emotional processing was investigated using event-related potential paradigms (ERPs). ERPs associated with emotional processing of cannabis users, and non-using controls, were recorded and compared during an implicit and explicit emotional expression recognition and empathy task. Comparisons in P3 component mean amplitudes were made between cannabis users and controls. Results showed a significant decrease in the P3 amplitude in cannabis users compared to controls. Specifically, cannabis users showed reduced P3 amplitudes for implicit compared to explicit processing over centro-parietal sites which reversed, and was enhanced, at fronto-central sites. Cannabis users also showed a decreased P3 to happy faces, with an increase to angry faces, compared to controls. These effects appear to increase with those participants that self-reported the highest levels of cannabis consumption. Those cannabis users with the greatest consumption rates showed the largest P3 deficits for explicit processing and negative emotions. These data suggest that there is a complex relationship between cannabis consumption and emotion processing that appears to be modulated by attention. PMID:26926868

  13. Snake scales, partial exposure, and the Snake Detection Theory: A human event-related potentials study

    Science.gov (United States)

    Van Strien, Jan W.; Isbell, Lynne A.

    2017-01-01

    Studies of event-related potentials in humans have established larger early posterior negativity (EPN) in response to pictures depicting snakes than to pictures depicting other creatures. Ethological research has recently shown that macaques and wild vervet monkeys respond strongly to partially exposed snake models and scale patterns on the snake skin. Here, we examined whether snake skin patterns and partially exposed snakes elicit a larger EPN in humans. In Task 1, we employed pictures with close-ups of snake skins, lizard skins, and bird plumage. In task 2, we employed pictures of partially exposed snakes, lizards, and birds. Participants watched a random rapid serial visual presentation of these pictures. The EPN was scored as the mean activity (225–300 ms after picture onset) at occipital and parieto-occipital electrodes. Consistent with previous studies, and with the Snake Detection Theory, the EPN was significantly larger for snake skin pictures than for lizard skin and bird plumage pictures, and for lizard skin pictures than for bird plumage pictures. Likewise, the EPN was larger for partially exposed snakes than for partially exposed lizards and birds. The results suggest that the EPN snake effect is partly driven by snake skin scale patterns which are otherwise rare in nature. PMID:28387376

  14. The taste-visual cross-modal Stroop effect: An event-related brain potential study.

    Science.gov (United States)

    Xiao, X; Dupuis-Roy, N; Yang, X L; Qiu, J F; Zhang, Q L

    2014-03-28

    Event-related potentials (ERPs) were recorded to explore, for the first time, the electrophysiological correlates of the taste-visual cross-modal Stroop effect. Eighteen healthy participants were presented with a taste stimulus and a food image, and asked to categorize the image as "sweet" or "sour" by pressing the relevant button as quickly as possible. Accurate categorization of the image was faster when it was presented with a congruent taste stimulus (e.g., sour taste/image of lemon) than with an incongruent one (e.g., sour taste/image of ice cream). ERP analyses revealed a negative difference component (ND430-620) between 430 and 620ms in the taste-visual cross-modal Stroop interference. Dipole source analysis of the difference wave (incongruent minus congruent) indicated that two generators localized in the prefrontal cortex and the parahippocampal gyrus contributed to this taste-visual cross-modal Stroop effect. This result suggests that the prefrontal cortex is associated with the process of conflict control in the taste-visual cross-modal Stroop effect. Also, we speculate that the parahippocampal gyrus is associated with the process of discordant information in the taste-visual cross-modal Stroop effect. Copyright © 2014 IBRO. Published by Elsevier Ltd. All rights reserved.

  15. Psychometric considerations in the measurement of event-related brain potentials: Guidelines for measurement and reporting.

    Science.gov (United States)

    Clayson, Peter E; Miller, Gregory A

    2017-01-01

    Failing to consider psychometric issues related to reliability and validity, differential deficits, and statistical power potentially undermines the conclusions of a study. In research using event-related brain potentials (ERPs), numerous contextual factors (population sampled, task, data recording, analysis pipeline, etc.) can impact the reliability of ERP scores. The present review considers the contextual factors that influence ERP score reliability and the downstream effects that reliability has on statistical analyses. Given the context-dependent nature of ERPs, it is recommended that ERP score reliability be formally assessed on a study-by-study basis. Recommended guidelines for ERP studies include 1) reporting the threshold of acceptable reliability and reliability estimates for observed scores, 2) specifying the approach used to estimate reliability, and 3) justifying how trial-count minima were chosen. A reliability threshold for internal consistency of at least 0.70 is recommended, and a threshold of 0.80 is preferred. The review also advocates the use of generalizability theory for estimating score dependability (the generalizability theory analog to reliability) as an improvement on classical test theory reliability estimates, suggesting that the latter is less well suited to ERP research. To facilitate the calculation and reporting of dependability estimates, an open-source Matlab program, the ERP Reliability Analysis Toolbox, is presented. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. Impaired Empathy Processing in Individuals with Internet Addiction Disorder: An Event-Related Potential Study

    Directory of Open Access Journals (Sweden)

    Can Jiao

    2017-10-01

    Full Text Available Internet addiction disorder (IAD is associated with deficits in social communication and avoidance of social contact. It has been hypothesized that people with IAD may have an impaired capacity for empathy. The purpose of the current study was to examine the processing of empathy for others’ pain in IADs. Event-related potentials produced in response to pictures showing others in painful and non-painful situations were recorded in 16 IAD subjects and 16 healthy controls (HCs. The N1, P2, N2, P3, and late positive potential components were compared between the two groups. Robust picture × group interactions were observed for N2 and P3. The painful pictures elicited larger N2 and P3 amplitudes than the non-painful pictures did only in the HC group but not in the IAD group. The results of this study suggest that both of the early automatic and of the later cognitive processes of pain empathy may be impaired in IADs. This study provides psychophysical evidence of empathy deficits in association with IAD. Further studies combining multidimensional measurements of empathy are needed to confirm these findings.

  17. Event-related potential evidence of accessing gender stereotypes to aid source monitoring.

    Science.gov (United States)

    Leynes, P Andrew; Crawford, Jarret T; Radebaugh, Anne M; Taranto, Elizabeth

    2013-01-23

    Source memory for the speaker's voice (male or female) was investigated when semantic knowledge (gender stereotypes) could and could not inform the episodic source judgment while event-related potentials (ERPs) were recorded. Source accuracy was greater and response times were faster when stereotypes could predict the speaker's voice at test. Recollection supported source judgments in both conditions as indicated by significant parietal "old/new" ERP effects (500-800ms). Prototypical late ERP effects (the right frontal "old/new" effect and the late posterior negativity, LPN) were evident when source judgment was based solely on episodic memory. However, these two late ERP effects were diminished and a novel, frontal-negative ERP with left-central topography was observed when stereotypes aided source judgments. This pattern of ERP activity likely reflects activation of left frontal or left temporal lobes when semantic knowledge, in the form of a gender stereotype, is accessed to inform the episodic source judgment. Copyright © 2012 Elsevier B.V. All rights reserved.

  18. The influence of caffeine on spatial-selective attention: an event-related potential study.

    Science.gov (United States)

    Ruijter, J; de Ruiter, M B; Snel, J; Lorist, M M

    2000-12-01

    Following the indications of previous studies that caffeine might have a specific effect on the processing of spatial information compared with other types of information, the present study investigated the influence of caffeine on an often used spatial-selective attention task. Event-related potentials (ERPs) were recorded from 11 participants under conditions of caffeine (250 mg) and placebo. Spatial-selective attention effects were reflected in the ERPs as more positive going occipital P1 and broadly distributed P2 components, and more negative going occipital-temporal N1 and broadly distributed N2 components. A treatment effect was found as a more positive going frontal P2 component in the caffeine condition, whereas interactions between treatment and attention were observed for P2 and N2 components, but not for P1 and N1 components. This pattern of results suggests that caffeine has no specific influence on spatial-selective attention, but rather, has a more general facilitating effect on perceptual processing, as well as a possible effect on the frontal control mechanisms, i.e. focusing attention and increasing selectivity.

  19. From mind to mouth: event related potentials of sentence production in classic galactosemia.

    Directory of Open Access Journals (Sweden)

    Inge Timmers

    Full Text Available Patients with classic galactosemia, an inborn error of metabolism, have speech and language production impairments. Past research primarily focused on speech (motor problems, but these cannot solely explain the language impairments. Which specific deficits contribute to the impairments in language production is not yet known. Deficits in semantic and syntactic planning are plausible and require further investigation. In the present study, we examined syntactic encoding while patients and matched controls overtly described scenes of moving objects using either separate words (minimal syntactic planning or sentences (sentence-level syntactic planning. The design of the paradigm also allowed tapping into local noun phrase- and more global sentence-level syntactic planning. Simultaneously, we recorded event-related potentials (ERPs. The patients needed more time to prepare and finish the utterances and made more errors. The patient ERPs had a very similar morphology to that of healthy controls, indicating overall comparable neural processing. Most importantly, the ERPs diverged from those of controls in several functionally informative time windows, ranging from very early (90-150 ms post scene onset to relatively late (1820-2020 ms post scene onset. These time windows can be associated with different linguistic encoding stages. The ERP results form the first neuroscientific evidence for language production impairments in patients with galactosemia in lexical and syntactic planning stages, i.e., prior to the linguistic output phase. These findings hence shed new light on the language impairments in this disease.

  20. Event-related potentials elicited during working memory are altered in mild cognitive impairment.

    Science.gov (United States)

    López Zunini, Rocío A; Knoefel, Frank; Lord, Courtney; Dzuali, Fiatsogbe; Breau, Michael; Sweet, Lisa; Goubran, Rafik; Taler, Vanessa

    2016-11-01

    Persons with Mild Cognitive Impairment (MCI) can experience deficits in working memory. In the present study, we investigated working memory in persons with MCI and cognitively healthy older adults using event-related potentials (ERPs). Participants performed an n-back working memory task with baseline (0-back), low load (1-back), and high load (2-back) working memory conditions. MCI participants' performance was less accurate than that of healthy older adults in both the 1-back and 2-back conditions, and reaction times were longer in MCI than control participants in the 0-back, 1-back and 2-back conditions. ERP analyses revealed delayed P200 and N200 latencies and smaller P300 amplitudes in MCI relative to control participants in the 0-back, 1-back and 2-back conditions. Deterioration in working memory performance concomitant with marked electrophysiological alterations suggests that persons with MCI exhibit deficits in several cognitive processes that include early attention, stimulus discrimination and classification, and updating and manipulation of information held in working memory. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. The application of particle filters in single trial event-related potential estimation

    International Nuclear Information System (INIS)

    Mohseni, Hamid R; Nazarpour, Kianoush; Sanei, Saeid; Wilding, Edward L

    2009-01-01

    In this paper, an approach for the estimation of single trial event-related potentials (ST-ERPs) using particle filters (PFs) is presented. The method is based on recursive Bayesian mean square estimation of ERP wavelet coefficients using their previous estimates as prior information. To enable a performance evaluation of the approach in the Gaussian and non-Gaussian distributed noise conditions, we added Gaussian white noise (GWN) and real electroencephalogram (EEG) signals recorded during rest to the simulated ERPs. The results were compared to that of the Kalman filtering (KF) approach demonstrating the robustness of the PF over the KF to the added GWN noise. The proposed method also outperforms the KF when the assumption about the Gaussianity of the noise is violated. We also applied this technique to real EEG potentials recorded in an odd-ball paradigm and investigated the correlation between the amplitude and the latency of the estimated ERP components. Unlike the KF method, for the PF there was a statistically significant negative correlation between amplitude and latency of the estimated ERPs, matching previous neurophysiological findings

  2. Do Event-Related Evoked Potentials Reflect Apathy Tendency and Motivation?

    Science.gov (United States)

    Takayoshi, Hiroyuki; Onoda, Keiichi; Yamaguchi, Shuhei

    2018-01-01

    Apathy is a mental state of diminished motivation. Although the reward system as the foundation of the motivation in the human brain has been studied extensively with neuroimaging techniques, the electrophysiological correlates of motivation and apathy have not been fully explored. Thus, in 14 healthy volunteers, we examined whether event-related evoked potentials (ERP) obtained during a simple number discrimination task with/without rewards reflected apathy tendency and a reward-dependent tendency, which were assessed separately using the apathy scale and the temperament and character inventory (TCI). Participants were asked to judge the size of a number, and received feedback based on their performance in each trial. The P3 amplitudes related to the feedback stimuli increased only in the reward condition. Furthermore, the P2 amplitudes related to the negative feedback stimuli in the reward condition had a positive correlation with the reward-dependent tendency in TCI, whereas the P3 amplitudes related to the positive feedback stimuli had a negative correlation with the apathy score. Our result suggests that the P2 and P3 ERPs to reward-related feedback stimuli are modulated in a distinctive manner by the motivational reward dependence and apathy tendency, and thus the current paradigm may be useful for investigating the brain activity associated with motivation. PMID:29445331

  3. Age-related differences in event-related potentials for early visual processing of emotional faces.

    Science.gov (United States)

    Hilimire, Matthew R; Mienaltowski, Andrew; Blanchard-Fields, Fredda; Corballis, Paul M

    2014-07-01

    With advancing age, processing resources are shifted away from negative emotional stimuli and toward positive ones. Here, we explored this 'positivity effect' using event-related potentials (ERPs). Participants identified the presence or absence of a visual probe that appeared over photographs of emotional faces. The ERPs elicited by the onsets of angry, sad, happy and neutral faces were recorded. We examined the frontocentral emotional positivity (FcEP), which is defined as a positive deflection in the waveforms elicited by emotional expressions relative to neutral faces early on in the time course of the ERP. The FcEP is thought to reflect enhanced early processing of emotional expressions. The results show that within the first 130 ms young adults show an FcEP to negative emotional expressions, whereas older adults show an FcEP to positive emotional expressions. These findings provide additional evidence that the age-related positivity effect in emotion processing can be traced to automatic processes that are evident very early in the processing of emotional facial expressions. © The Author (2013). Published by Oxford University Press. For Permissions, please email: journals.permissions@oup.com.

  4. Short-Term Effects of Prosocial Video Games on Aggression: An Event-Related Potential Study

    Directory of Open Access Journals (Sweden)

    Yanling eLiu

    2015-07-01

    Full Text Available Previous research has shown that exposure to violent video games increases aggression, whereas exposure to prosocial video games can reduce aggressive behavior. However, little is known about the neural correlates of these behavioral effects. This work is the first to investigate the electrophysiological features of the relationship between playing a prosocial video game and inhibition of aggressive behavior. Forty-nine subjects played either a prosocial or a neutral video game for 20 minutes, then participated in an event-related potential (ERP experiment based on an oddball paradigm and designed to test electrophysiological responses to prosocial and violent words. Finally, subjects completed a competitive reaction time task (CRTT, which is based on Taylor’s Aggression Paradigm and measures both reaction time and noise intensity preference as indices of aggressive behavior. The results show that the prosocial video game group (compared to the neutral video game group displayed smaller P300 amplitudes, were more accurate in distinguishing violent words, and were less aggressive as evaluated by the CRTT (noise intensity preference. A mediation analysis shows that the P300 amplitude evoked by violent words partially mediates the relationship between type of video game and subsequent aggressive behavior. The results support theories based on the General Learning Model. We provide converging behavioral and neural evidence that exposure to prosocial media may reduce aggression.

  5. False memory and level of processing effect: an event-related potential study.

    Science.gov (United States)

    Beato, Maria Soledad; Boldini, Angela; Cadavid, Sara

    2012-09-12

    Event-related potentials (ERPs) were used to determine the effects of level of processing on true and false memory, using the Deese-Roediger-McDermott (DRM) paradigm. In the DRM paradigm, lists of words highly associated to a single nonpresented word (the 'critical lure') are studied and, in a subsequent memory test, critical lures are often falsely remembered. Lists with three critical lures per list were auditorily presented here to participants who studied them with either a shallow (saying whether the word contained the letter 'o') or a deep (creating a mental image of the word) processing task. Visual presentation modality was used on a final recognition test. True recognition of studied words was significantly higher after deep encoding, whereas false recognition of nonpresented critical lures was similar in both experimental groups. At the ERP level, true and false recognition showed similar patterns: no FN400 effect was found, whereas comparable left parietal and late right frontal old/new effects were found for true and false recognition in both experimental conditions. Items studied under shallow encoding conditions elicited more positive ERP than items studied under deep encoding conditions at a 1000-1500 ms interval. These ERP results suggest that true and false recognition share some common underlying processes. Differential effects of level of processing on true and false memory were found only at the behavioral level but not at the ERP level.

  6. A feasibility study of using event-related potential as a biometrics.

    Science.gov (United States)

    Yih-Choung Yu; Sicheng Wang; Gabel, Lisa A

    2016-08-01

    The use of an individual's neural response to stimuli (the event-related potential or ERP) has potential as a biometric because it is highly resistant to fraud relative to other conventional authentication systems. P300 is an ERP in human electroencephalography (EEG) that occurs in response to an oddball stimulus when an individual is actively engaged in a target detection task. Because P300 is consistently detectable from almost every subject, it is considered a potential signal for biometric applications. This paper presents a feasibility study of using topological plots of P300 as a biometric in subject authentication. The variation in latency and location of P300 response of 24 participants performing the P300Speller task were studied. Data sets from four participants were used for algorithm training; data from the other 20 participants were used as imposters for algorithm validation. The result showed that the algorithm was able to correctly identify three out of these four participants. Validation test also proved that the algorithm was able to reject 95% of the imposters for those three authenticated participants.

  7. Causality in the association between P300 and alpha event-related desynchronization.

    Directory of Open Access Journals (Sweden)

    Weiwei Peng

    Full Text Available Recent findings indicated that both P300 and alpha event-related desynchronization (α-ERD were associated, and similarly involved in cognitive brain functioning, e.g., attention allocation and memory updating. However, an explicit causal influence between the neural generators of P300 and α-ERD has not yet been investigated. In the present study, using an oddball task paradigm, we assessed the task effect (target vs. non-target on P300 and α-ERD elicited by stimuli of four sensory modalities, i.e., audition, vision, somatosensory, and pain, estimated their respective neural generators, and investigated the information flow among their neural generators using time-varying effective connectivity in the target condition. Across sensory modalities, the scalp topographies of P300 and α-ERD were similar and respectively maximal at parietal and occipital regions in the target condition. Source analysis revealed that P300 and α-ERD were mainly generated from posterior cingulate cortex and occipital lobe respectively. As revealed by time-varying effective connectivity, the cortical information was consistently flowed from α-ERD sources to P300 sources in the target condition for all four sensory modalities. All these findings showed that P300 in the target condition is modulated by the changes of α-ERD, which would be useful to explore neural mechanism of cognitive information processing in the human brain.

  8. Response inhibition in borderline personality disorder: event-related potentials in a Go/Nogo task.

    Science.gov (United States)

    Ruchsow, M; Groen, G; Kiefer, M; Buchheim, A; Walter, H; Martius, P; Reiter, M; Hermle, L; Spitzer, M; Ebert, D; Falkenstein, M

    2008-01-01

    Borderline personality disorder (BPD) has been related to a dysfunction of anterior cingulate cortex, amygdala, and prefrontal cortex and has been associated clinically with impulsivity, affective instability, and significant interpersonal distress. We examined 17 patients with BPD and 17 age-, sex-, and education matched control participants with no history of Axis I or II psychopathology using event-related potentials (ERPs). Participants performed a hybrid flanker-Go/Nogo task while multichannel EEG was recorded. Our study focused on two ERP components: the Nogo-N2 and the Nogo-P3, which have been discussed in the context of response inhibition and response conflict. ERPs were computed on correct Go trials (button press) and correct Nogo trials (no button press), separately. Groups did not differ with regard to the Nogo-N2. However, BPD patients showed reduced Nogo-P3 amplitudes. For the entire group (n = 34) we found a negative correlation with the Barratt Impulsiveness Scale (BIS-10) and Becks's depression inventory (BDI). The present study is the first to examine Nogo-N2 and Nogo-P3 in BPD and provides further evidence for impaired response inhibition in BPD patients.

  9. [Event-related EEG potentials associated with error detection in psychiatric disorder: literature review].

    Science.gov (United States)

    Balogh, Lívia; Czobor, Pál

    2010-01-01

    Error-related bioelectric signals constitute a special subgroup of event-related potentials. Researchers have identified two evoked potential components to be closely related to error processing, namely error-related negativity (ERN) and error-positivity (Pe), and they linked these to specific cognitive functions. In our article first we give a brief description of these components, then based on the available literature, we review differences in error-related evoked potentials observed in patients across psychiatric disorders. The PubMed and Medline search engines were used in order to identify all relevant articles, published between 2000 and 2009. For the purpose of the current paper we reviewed publications summarizing results of clinical trials. Patients suffering from schizophrenia, anorexia nervosa or borderline personality disorder exhibited a decrease in the amplitude of error-negativity when compared with healthy controls, while in cases of depression and anxiety an increase in the amplitude has been observed. Some of the articles suggest specific personality variables, such as impulsivity, perfectionism, negative emotions or sensitivity to punishment to underlie these electrophysiological differences. Research in the field of error-related electric activity has come to the focus of psychiatry research only recently, thus the amount of available data is significantly limited. However, since this is a relatively new field of research, the results available at present are noteworthy and promising for future electrophysiological investigations in psychiatric disorders.

  10. Event-related potential correlates of suspicious thoughts in individuals with schizotypal personality features.

    Science.gov (United States)

    Li, Xue-bing; Huang, Jia; Cheung, Eric F C; Gong, Qi-yong; Chan, Raymond C K

    2011-01-01

    Suspiciousness is a common feature of schizophrenia. However, suspicious thoughts are also commonly experienced by the general population. This study aimed to examine the underlying neural mechanism of suspicious thoughts in individuals with and without schizotypal personality disorder (SPD)-proneness, using an event-related potential (ERP) paradigm. Electroencephalography (EEG) was recorded when the "feeling of being seen through" was evoked in the participants. The findings showed a prominent positive deflection of the difference wave within the time window 250-400 ms after stimuli presentation in both SPD-prone and non-SPD-prone groups. Furthermore, the P3 amplitude was significantly reduced in the SPD-prone group compared to the non-SPD-prone group. The current density analysis also indicated hypoactivity in both frontal and temporal regions in the SPD-prone group, suggesting that the frontotemporal cortical network may play a role in the onset of suspicious thoughts. The P3 of difference wave was inversely correlated with the cognitive-perception factor and the suspiciousness/paranoid ideation trait, which provided preliminary electrophysiological evidence for the association of suspiciousness with SPD features.

  11. Event-related potential responses to perceptual reversals are modulated by working memory load.

    Science.gov (United States)

    Intaitė, Monika; Koivisto, Mika; Castelo-Branco, Miguel

    2014-04-01

    While viewing ambiguous figures, such as the Necker cube, the available perceptual interpretations alternate with one another. The role of higher level mechanisms in such reversals remains unclear. We tested whether perceptual reversals of discontinuously presented Necker cube pairs depend on working memory resources by manipulating cognitive load while recording event-related potentials (ERPs). The ERPs showed early enhancements of negativity, which were obtained in response to the first cube approximately 500 ms before perceived reversals. We found that working memory load influenced reversal-related brain responses in response to the second cube over occipital areas at the 150-300 ms post-stimulus and over central areas at P3 time window (300-500 ms), suggesting that it modulates intermediate visual processes. Interestingly, reversal rates remained unchanged by the working memory load. We propose that perceptual reversals in discontinuous presentation of ambiguous stimuli are governed by an early (well preceding pending reversals) mechanism, while the effects of load on the reversal related ERPs may reflect general top-down influences on visual processing, possibly mediated by the prefrontal cortex. Copyright © 2014 Elsevier Ltd. All rights reserved.

  12. Neurophysiological Effects of Meditation Based on Evoked and Event Related Potential Recordings.

    Science.gov (United States)

    Singh, Nilkamal; Telles, Shirley

    2015-01-01

    Evoked potentials (EPs) are a relatively noninvasive method to assess the integrity of sensory pathways. As the neural generators for most of the components are relatively well worked out, EPs have been used to understand the changes occurring during meditation. Event-related potentials (ERPs) yield useful information about the response to tasks, usually assessing attention. A brief review of the literature yielded eleven studies on EPs and seventeen on ERPs from 1978 to 2014. The EP studies covered short, mid, and long latency EPs, using both auditory and visual modalities. ERP studies reported the effects of meditation on tasks such as the auditory oddball paradigm, the attentional blink task, mismatched negativity, and affective picture viewing among others. Both EP and ERPs were recorded in several meditations detailed in the review. Maximum changes occurred in mid latency (auditory) EPs suggesting that maximum changes occur in the corresponding neural generators in the thalamus, thalamic radiations, and primary auditory cortical areas. ERP studies showed meditation can increase attention and enhance efficiency of brain resource allocation with greater emotional control.

  13. Event-related potentials during word mapping to object shape predict toddlers’ vocabulary size

    Directory of Open Access Journals (Sweden)

    Kristina eBorgström

    2015-02-01

    Full Text Available What role does attention to different object properties play in early vocabulary development? This longitudinal study using event-related potentials in combination with behavioral measures investigated 20- and 24-month-olds’ (n = 38; n = 34; overlapping n = 24 ability to use object shape and object part information in word-object mapping. The N400 component was used to measure semantic priming by images containing shape or detail information. At 20 months, the N400 to words primed by object shape varied in topography and amplitude depending on vocabulary size, and these differences predicted productive vocabulary size at 24 months. At 24 months, when most of the children had vocabularies of several hundred words, the relation between vocabulary size and the N400 effect in a shape context was weaker. Detached object parts did not function as word primes regardless of age or vocabulary size, although the part-objects were identified behaviorally. The behavioral measure, however, also showed relatively poor recognition of the part-objects compared to the shape-objects. These three findings provide new support for the link between shape recognition and early vocabulary development.

  14. Event-related potentials reveal the relations between feature representations at different levels of abstraction.

    Science.gov (United States)

    Hannah, Samuel D; Shedden, Judith M; Brooks, Lee R; Grundy, John G

    2016-11-01

    In this paper, we use behavioural methods and event-related potentials (ERPs) to explore the relations between informational and instantiated features, as well as the relation between feature abstraction and rule type. Participants are trained to categorize two species of fictitious animals and then identify perceptually novel exemplars. Critically, two groups are given a perfectly predictive counting rule that, according to Hannah and Brooks (2009. Featuring familiarity: How a familiar feature instantiation influences categorization. Canadian Journal of Experimental Psychology/Revue Canadienne de Psychologie Expérimentale, 63, 263-275. Retrieved from http://doi.org/10.1037/a0017919), should orient them to using abstract informational features when categorizing the novel transfer items. A third group is taught a feature list rule, which should orient them to using detailed instantiated features. One counting-rule group were taught their rule before any exposure to the actual stimuli, and the other immediately after training, having learned the instantiations first. The feature-list group were also taught their rule after training. The ERP results suggest that at test, the two counting-rule groups processed items differently, despite their identical rule. This not only supports the distinction that informational and instantiated features are qualitatively different feature representations, but also implies that rules can readily operate over concrete inputs, in contradiction to traditional approaches that assume that rules necessarily act on abstract inputs.

  15. Neurophysiological Effects of Meditation Based on Evoked and Event Related Potential Recordings

    Science.gov (United States)

    Singh, Nilkamal; Telles, Shirley

    2015-01-01

    Evoked potentials (EPs) are a relatively noninvasive method to assess the integrity of sensory pathways. As the neural generators for most of the components are relatively well worked out, EPs have been used to understand the changes occurring during meditation. Event-related potentials (ERPs) yield useful information about the response to tasks, usually assessing attention. A brief review of the literature yielded eleven studies on EPs and seventeen on ERPs from 1978 to 2014. The EP studies covered short, mid, and long latency EPs, using both auditory and visual modalities. ERP studies reported the effects of meditation on tasks such as the auditory oddball paradigm, the attentional blink task, mismatched negativity, and affective picture viewing among others. Both EP and ERPs were recorded in several meditations detailed in the review. Maximum changes occurred in mid latency (auditory) EPs suggesting that maximum changes occur in the corresponding neural generators in the thalamus, thalamic radiations, and primary auditory cortical areas. ERP studies showed meditation can increase attention and enhance efficiency of brain resource allocation with greater emotional control. PMID:26137479

  16. Lexical ambiguity resolution during sentence processing in Parkinson's disease: An event-related potential study.

    Directory of Open Access Journals (Sweden)

    Anthony J Angwin

    Full Text Available Event-related potentials (ERPs were recorded to investigate lexical ambiguity resolution during sentence processing in 16 people with Parkinson's disease (PD and 16 healthy controls. Sentences were presented word-by-word on computer screen, and participants were required to decide if a subsequent target word was related to the meaning of the sentence. The task consisted of related, unrelated and ambiguous trials. For the ambiguous trials, the sentence ended with an ambiguous word and the target was related to one of the meanings of that word, but not the one captured by the sentence context (e.g., 'He dug with the spade', Target 'ACE'. Both groups demonstrated slower reaction times and lower accuracy for the ambiguous condition relative to the unrelated condition, however accuracy was impacted by the ambiguous condition to a larger extent in the PD group. These results suggested that PD patients experience increased difficulties with contextual ambiguity resolution. The ERP results did not reflect increased ambiguity resolution difficulties in PD, as a similar N400 effect was evident for the unrelated and ambiguous condition in both groups. However, the magnitude of the N400 for these conditions was correlated with a measure of inhibition in the PD group, but not the control group. The ERP results suggest that semantic processing may be more compromised in PD patients with increased response inhibition deficits.

  17. Cognitive processing in non-communicative patients: what can event-related potentials tell us?

    Directory of Open Access Journals (Sweden)

    Zulay Rosario Lugo

    2016-11-01

    Full Text Available Event-related potentials (ERP have been proposed to improve the differential diagnosis of non-responsive patients. We investigated the potential of the P300 as a reliable marker of conscious processing in patients with locked-in syndrome (LIS. Eleven chronic LIS patients and ten healthy subjects (HS listened to a complex-tone auditory oddball paradigm, first in a passive condition (listen to the sounds and then in an active condition (counting the deviant tones. Seven out of nine HS displayed a P300 waveform in the passive condition and all in the active condition. HS showed statistically significant changes in peak and area amplitude between conditions. Three out of seven LIS patients showed the P3 waveform in the passive condition and 5 of 7 in the active condition. No changes in peak amplitude and only a significant difference at one electrode in area amplitude were observed in this group between conditions. We conclude that, in spite of keeping full consciousness and intact or nearly intact cortical functions, compared to HS, LIS patients present less reliable results when testing with ERP, specifically in the passive condition. We thus strongly recommend applying ERP paradigms in an active condition when evaluating consciousness in non-responsive patients.

  18. Event-Related Potentials for Post-Error and Post-Conflict Slowing

    Science.gov (United States)

    Chang, Andrew; Chen, Chien-Chung; Li, Hsin-Hung; Li, Chiang-Shan R.

    2014-01-01

    In a reaction time task, people typically slow down following an error or conflict, each called post-error slowing (PES) and post-conflict slowing (PCS). Despite many studies of the cognitive mechanisms, the neural responses of PES and PCS continue to be debated. In this study, we combined high-density array EEG and a stop-signal task to examine event-related potentials of PES and PCS in sixteen young adult participants. The results showed that the amplitude of N2 is greater during PES but not PCS. In contrast, the peak latency of N2 is longer for PCS but not PES. Furthermore, error-positivity (Pe) but not error-related negativity (ERN) was greater in the stop error trials preceding PES than non-PES trials, suggesting that PES is related to participants' awareness of the error. Together, these findings extend earlier work of cognitive control by specifying the neural correlates of PES and PCS in the stop signal task. PMID:24932780

  19. A hierarchy of event-related potential markers of auditory processing in disorders of consciousness

    Directory of Open Access Journals (Sweden)

    Steve Beukema

    2016-01-01

    Full Text Available Functional neuroimaging of covert perceptual and cognitive processes can inform the diagnoses and prognoses of patients with disorders of consciousness, such as the vegetative and minimally conscious states (VS;MCS. Here we report an event-related potential (ERP paradigm for detecting a hierarchy of auditory processes in a group of healthy individuals and patients with disorders of consciousness. Simple cortical responses to sounds were observed in all 16 patients; 7/16 (44% patients exhibited markers of the differential processing of speech and noise; and 1 patient produced evidence of the semantic processing of speech (i.e. the N400 effect. In several patients, the level of auditory processing that was evident from ERPs was higher than the abilities that were evident from behavioural assessment, indicating a greater sensitivity of ERPs in some cases. However, there were no differences in auditory processing between VS and MCS patient groups, indicating a lack of diagnostic specificity for this paradigm. Reliably detecting semantic processing by means of the N400 effect in passively listening single-subjects is a challenge. Multiple assessment methods are needed in order to fully characterise the abilities of patients with disorders of consciousness.

  20. Do Event-Related Evoked Potentials Reflect Apathy Tendency and Motivation?

    Directory of Open Access Journals (Sweden)

    Hiroyuki Takayoshi

    2018-01-01

    Full Text Available Apathy is a mental state of diminished motivation. Although the reward system as the foundation of the motivation in the human brain has been studied extensively with neuroimaging techniques, the electrophysiological correlates of motivation and apathy have not been fully explored. Thus, in 14 healthy volunteers, we examined whether event-related evoked potentials (ERP obtained during a simple number discrimination task with/without rewards reflected apathy tendency and a reward-dependent tendency, which were assessed separately using the apathy scale and the temperament and character inventory (TCI. Participants were asked to judge the size of a number, and received feedback based on their performance in each trial. The P3 amplitudes related to the feedback stimuli increased only in the reward condition. Furthermore, the P2 amplitudes related to the negative feedback stimuli in the reward condition had a positive correlation with the reward-dependent tendency in TCI, whereas the P3 amplitudes related to the positive feedback stimuli had a negative correlation with the apathy score. Our result suggests that the P2 and P3 ERPs to reward-related feedback stimuli are modulated in a distinctive manner by the motivational reward dependence and apathy tendency, and thus the current paradigm may be useful for investigating the brain activity associated with motivation.

  1. Short-term effects of prosocial video games on aggression: an event-related potential study

    Science.gov (United States)

    Liu, Yanling; Teng, Zhaojun; Lan, Haiying; Zhang, Xin; Yao, Dezhong

    2015-01-01

    Previous research has shown that exposure to violent video games increases aggression, whereas exposure to prosocial video games can reduce aggressive behavior. However, little is known about the neural correlates of these behavioral effects. This work is the first to investigate the electrophysiological features of the relationship between playing a prosocial video game and inhibition of aggressive behavior. Forty-nine subjects played either a prosocial or a neutral video game for 20 min, then participated in an event-related potential (ERP) experiment based on an oddball paradigm and designed to test electrophysiological responses to prosocial and violent words. Finally, subjects completed a competitive reaction time task (CRTT) which based on Taylor's Aggression Paradigm and contains reaction time and noise intensity chosen as a measure of aggressive behavior. The results show that the prosocial video game group (compared to the neutral video game group) displayed smaller P300 amplitudes, were more accurate in distinguishing violent words, and were less aggressive as evaluated by the CRTT of noise intensity chosen. A mediation analysis shows that the P300 amplitude evoked by violent words partially mediates the relationship between type of video game and subsequent aggressive behavior. The results support theories based on the General Learning Model. We provide converging behavioral and neural evidence that exposure to prosocial media may reduce aggression. PMID:26257620

  2. A frontal cortex event-related potential driven by the basal forebrain

    Science.gov (United States)

    Nguyen, David P; Lin, Shih-Chieh

    2014-01-01

    Event-related potentials (ERPs) are widely used in both healthy and neuropsychiatric conditions as physiological indices of cognitive functions. Contrary to the common belief that cognitive ERPs are generated by local activity within the cerebral cortex, here we show that an attention-related ERP in the frontal cortex is correlated with, and likely generated by, subcortical inputs from the basal forebrain (BF). In rats performing an auditory oddball task, both the amplitude and timing of the frontal ERP were coupled with BF neuronal activity in single trials. The local field potentials (LFPs) associated with the frontal ERP, concentrated in deep cortical layers corresponding to the zone of BF input, were similarly coupled with BF activity and consistently triggered by BF electrical stimulation within 5–10 msec. These results highlight the important and previously unrecognized role of long-range subcortical inputs from the BF in the generation of cognitive ERPs. DOI: http://dx.doi.org/10.7554/eLife.02148.001 PMID:24714497

  3. Toward brain-computer interface based wheelchair control utilizing tactually-evoked event-related potentials

    Science.gov (United States)

    2014-01-01

    Background People with severe disabilities, e.g. due to neurodegenerative disease, depend on technology that allows for accurate wheelchair control. For those who cannot operate a wheelchair with a joystick, brain-computer interfaces (BCI) may offer a valuable option. Technology depending on visual or auditory input may not be feasible as these modalities are dedicated to processing of environmental stimuli (e.g. recognition of obstacles, ambient noise). Herein we thus validated the feasibility of a BCI based on tactually-evoked event-related potentials (ERP) for wheelchair control. Furthermore, we investigated use of a dynamic stopping method to improve speed of the tactile BCI system. Methods Positions of four tactile stimulators represented navigation directions (left thigh: move left; right thigh: move right; abdomen: move forward; lower neck: move backward) and N = 15 participants delivered navigation commands by focusing their attention on the desired tactile stimulus in an oddball-paradigm. Results Participants navigated a virtual wheelchair through a building and eleven participants successfully completed the task of reaching 4 checkpoints in the building. The virtual wheelchair was equipped with simulated shared-control sensors (collision avoidance), yet these sensors were rarely needed. Conclusion We conclude that most participants achieved tactile ERP-BCI control sufficient to reliably operate a wheelchair and dynamic stopping was of high value for tactile ERP classification. Finally, this paper discusses feasibility of tactile ERPs for BCI based wheelchair control. PMID:24428900

  4. The arithmetic problem size effect in children: an event-related potential study

    Directory of Open Access Journals (Sweden)

    Leen eVan Beek

    2014-09-01

    Full Text Available This study used for the first time event-related potentials (ERPs to examine the well-known arithmetic problem size effect in children. The electrophysiological correlates of this problem size effect have been well documented in adults, but such information in children is lacking. In the present study, 22 typically developing 12-year-olds were asked to solve single-digit addition problems of small (sum ≤ 10 and large problem size (sum > 10 and to speak the solution into a voice key while ERPs were recorded. Children displayed similar early and late components compared to previous adult studies on the problem size effect. There was no effect of problem size on the early components P1, N1 and P2. The peak amplitude of the N2 component showed more negative potentials on left and right anterior electrodes for large additions compared to small additions, which might reflect differences in attentional and working memory resources between large and small problems. The mean amplitude of the late positivity component (LPC, which follows the N2, was significantly larger for large than for small additions at right parieto-occipital electrodes, in line with previous adult data. The ERPs of the problem size effect during arithmetic might be a useful neural marker for future studies on fact retrieval impairments in children with mathematical difficulties.

  5. Target-directed motor imagery of the lower limb enhances event-related desynchronization.

    Directory of Open Access Journals (Sweden)

    Kosuke Kitahara

    Full Text Available Event-related desynchronization/synchronization (ERD/S is an electroencephalogram (EEG feature widely used as control signals for Brain-Computer Interfaces (BCIs. Nevertheless, the underlying neural mechanisms and functions of ERD/S are largely unknown, thus investigating them is crucial to improve the reliability of ERD/S-based BCIs. This study aimed to identify Motor Imagery (MI conditions that enhance ERD/S. We investigated following three questions: 1 whether target-directed MI affects ERD/S, 2 whether MI with sound imagery affects ERD/S, and 3 whether ERD/S has a body part dependency of MI. Nine participants took part in the experiments of four MI conditions; they were asked to imagine right foot dorsiflexion (F, right foot dorsiflexion and the sound of a bass drum when the sole touched the floor (FS, right leg extension (L, and right leg extension directed toward a soccer ball (LT. Statistical comparison revealed that there were significant differences between conditions L and LT in beta-band ERD and conditions F and L in beta-band ERS. These results suggest that mental rehearsal of target-directed lower limb movement without real sensory stimuli can enhance beta-band ERD; furthermore, MI of foot dorsiflexion induces significantly larger beta-band ERS than that of leg extension. These findings could be exploited for the training of BCIs such as powered prosthetics for disabled person and neurorehabilitation system for stroke patients.

  6. Evaluation of auditory perception development in neonates by event-related potential technique.

    Science.gov (United States)

    Zhang, Qinfen; Li, Hongxin; Zheng, Aibin; Dong, Xuan; Tu, Wenjuan

    2017-08-01

    To investigate auditory perception development in neonates and correlate it with days after birth, left and right hemisphere development and sex using event-related potential (ERP) technique. Sixty full-term neonates, consisting of 32 males and 28 females, aged 2-28days were included in this study. An auditory oddball paradigm was used to elicit ERPs. N2 wave latencies and areas were recorded at different days after birth, to study on relationship between auditory perception and age, and comparison of left and right hemispheres, and males and females. Average wave forms of ERPs in neonates started from relatively irregular flat-bottomed troughs to relatively regular steep-sided ripples. A good linear relationship between ERPs and days after birth in neonates was observed. As days after birth increased, N2 latencies gradually and significantly shortened, and N2 areas gradually and significantly increased (both Pbrain were significantly greater, and N2 latencies in the central part were significantly shorter in the left hemisphere compared with the right, indicative of left hemisphere dominance (both Pdevelopment. In the days following birth, the auditory perception ability of neonates gradually increases. This occurs predominantly in the left hemisphere, with auditory perception ability appearing to develop earlier in female neonates than in males. ERP can be used as an objective index used to evaluate auditory perception development in neonates. Copyright © 2017 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  7. Event-related potential evidence of form and meaning coding during online speech recognition.

    Science.gov (United States)

    Friedrich, Claudia K; Kotz, Sonja A

    2007-04-01

    It is still a matter of debate whether initial analysis of speech is independent of contextual influences or whether meaning can modulate word activation directly. Utilizing event-related brain potentials (ERPs), we tested the neural correlates of speech recognition by presenting sentences that ended with incomplete words, such as To light up the dark she needed her can-. Immediately following the incomplete words, subjects saw visual words that (i) matched form and meaning, such as candle; (ii) matched meaning but not form, such as lantern; (iii) matched form but not meaning, such as candy; or (iv) mismatched form and meaning, such as number. We report ERP evidence for two distinct cohorts of lexical tokens: (a) a left-lateralized effect, the P250, differentiates form-matching words (i, iii) and form-mismatching words (ii, iv); (b) a right-lateralized effect, the P220, differentiates words that match in form and/or meaning (i, ii, iii) from mismatching words (iv). Lastly, fully matching words (i) reduce the amplitude of the N400. These results accommodate bottom-up and top-down accounts of human speech recognition. They suggest that neural representations of form and meaning are activated independently early on and are integrated at a later stage during sentence comprehension.

  8. Coherence explored between emotion components: evidence from event-related potentials and facial electromyography.

    Science.gov (United States)

    Gentsch, Kornelia; Grandjean, Didier; Scherer, Klaus R

    2014-04-01

    Componential theories assume that emotion episodes consist of emergent and dynamic response changes to relevant events in different components, such as appraisal, physiology, motivation, expression, and subjective feeling. In particular, Scherer's Component Process Model hypothesizes that subjective feeling emerges when the synchronization (or coherence) of appraisal-driven changes between emotion components has reached a critical threshold. We examined the prerequisite of this synchronization hypothesis for appraisal-driven response changes in facial expression. The appraisal process was manipulated by using feedback stimuli, presented in a gambling task. Participants' responses to the feedback were investigated in concurrently recorded brain activity related to appraisal (event-related potentials, ERP) and facial muscle activity (electromyography, EMG). Using principal component analysis, the prediction of appraisal-driven response changes in facial EMG was examined. Results support this prediction: early cognitive processes (related to the feedback-related negativity) seem to primarily affect the upper face, whereas processes that modulate P300 amplitudes tend to predominantly drive cheek region responses. Copyright © 2013 Elsevier B.V. All rights reserved.

  9. Dissociation between morality and disgust: an event-related potential study.

    Science.gov (United States)

    Yang, Qun; Li, An; Xiao, Xiao; Zhang, Ye; Tian, Xuehong

    2014-10-01

    This study explored the neural correlates of morality and disgust, particularly, how the mechanisms that mediate our avoidance of physically disgusting and morally abhorrent behaviors are neurologically dissociated during the time-course of processing. Twelve participants were asked to judge the acceptability of different types of behaviors, which varied in their level of moral wrongness and physical disgust, while event-related potentials (ERPs) were recorded. The main results showed that the two morally wrong conditions elicited greater amplitudes of P300-400 at frontal sites than the neutral condition and the physically disgusting, but not morally wrong, condition. The physically disgusting conditions (with and without moral content) elicited significantly more positive deflections in the 500-600 ms timeframe than the neutral condition at central-posterior sites. These findings indicate that our aversion to harmful substances in the physical environment and offensive behaviors in the social environment may be neurologically dissociable in the temporal dimension. Furthermore, the detection of moral violations may be processed earlier in time than that of physical disgust. Copyright © 2014 Elsevier B.V. All rights reserved.

  10. Kernel PLS Estimation of Single-trial Event-related Potentials

    Science.gov (United States)

    Rosipal, Roman; Trejo, Leonard J.

    2004-01-01

    Nonlinear kernel partial least squaes (KPLS) regressior, is a novel smoothing approach to nonparametric regression curve fitting. We have developed a KPLS approach to the estimation of single-trial event related potentials (ERPs). For improved accuracy of estimation, we also developed a local KPLS method for situations in which there exists prior knowledge about the approximate latency of individual ERP components. To assess the utility of the KPLS approach, we compared non-local KPLS and local KPLS smoothing with other nonparametric signal processing and smoothing methods. In particular, we examined wavelet denoising, smoothing splines, and localized smoothing splines. We applied these methods to the estimation of simulated mixtures of human ERPs and ongoing electroencephalogram (EEG) activity using a dipole simulator (BESA). In this scenario we considered ongoing EEG to represent spatially and temporally correlated noise added to the ERPs. This simulation provided a reasonable but simplified model of real-world ERP measurements. For estimation of the simulated single-trial ERPs, local KPLS provided a level of accuracy that was comparable with or better than the other methods. We also applied the local KPLS method to the estimation of human ERPs recorded in an experiment on co,onitive fatigue. For these data, the local KPLS method provided a clear improvement in visualization of single-trial ERPs as well as their averages. The local KPLS method may serve as a new alternative to the estimation of single-trial ERPs and improvement of ERP averages.

  11. Nicotine enhances an auditory Event-Related Potential component which is inversely related to habituation.

    Science.gov (United States)

    Veltri, Theresa; Taroyan, Naira; Overton, Paul G

    2017-07-01

    Nicotine is a psychoactive substance that is commonly consumed in the context of music. However, the reason why music and nicotine are co-consumed is uncertain. One possibility is that nicotine affects cognitive processes relevant to aspects of music appreciation in a beneficial way. Here we investigated this possibility using Event-Related Potentials. Participants underwent a simple decision-making task (to maintain attentional focus), responses to which were signalled by auditory stimuli. Unlike previous research looking at the effects of nicotine on auditory processing, we used complex tones that varied in pitch, a fundamental element of music. In addition, unlike most other studies, we tested non-smoking subjects to avoid withdrawal-related complications. We found that nicotine (4.0 mg, administered as gum) increased P2 amplitude in the frontal region. Since a decrease in P2 amplitude and latency is related to habituation processes, and an enhanced ability to disengage from irrelevant stimuli, our findings suggest that nicotine may cause a reduction in habituation, resulting in non-smokers being less able to adapt to repeated stimuli. A corollary of that decrease in adaptation may be that nicotine extends the temporal window during which a listener is able and willing to engage with a piece of music.

  12. Neural Basis of Intrinsic Motivation: Evidence from Event-Related Potentials.

    Science.gov (United States)

    Jin, Jia; Yu, Liping; Ma, Qingguo

    2015-01-01

    Human intrinsic motivation is of great importance in human behavior. However, although researchers have focused on this topic for decades, its neural basis was still unclear. The current study employed event-related potentials to investigate the neural disparity between an interesting stop-watch (SW) task and a boring watch-stop task (WS) to understand the neural mechanisms of intrinsic motivation. Our data showed that, in the cue priming stage, the cue of the SW task elicited smaller N2 amplitude than that of the WS task. Furthermore, in the outcome feedback stage, the outcome of the SW task induced smaller FRN amplitude and larger P300 amplitude than that of the WS task. These results suggested that human intrinsic motivation did exist and that it can be detected at the neural level. Furthermore, intrinsic motivation could be quantitatively indexed by the amplitude of ERP components, such as N2, FRN, and P300, in the cue priming stage or feedback stage. Quantitative measurements would also be convenient for intrinsic motivation to be added as a candidate social factor in the construction of a machine learning model.

  13. Event-Related Potentials in Parkinson’s Disease: A Review

    Directory of Open Access Journals (Sweden)

    E. Růžička

    1993-01-01

    Full Text Available This article reviews the findings of event-related potentials (ERP in Parkinson's disease (PD published during the last 10 years. Basic principles and methods of ERP are briefly presented with particular regard to the auditory “odd-ball” paradigm almost uniquely employed for the ERP assessment in PD to date. The results of respective studies are overviewed and discussed with respect to three main axes: (1 The slowing down of cognitive processing in PD is reflected by the delays of N2 and P3 components of ERP which are more important in demented than in non-demented patients. The Nl component is delayed in demented patients with PD as well as in other dementias of presumed subcortical origin. (2 Various neuropsychological deficits observed in PD correlate with the delays of ERP evoking the implication of common subcortico-cortical cerebral mechanisms. (3 The variations of ERP under dopaminergic manipulation suggest conflicting effects of levodopa treatment on cognition, at least in certain categories of PD patients. These findings are discussed in the light of current knowledge on neurotransmitter brain systems and some hypothetic explanations are proposed. Finally, an attempt is made to outline further perspectives of clinical and research utilization of ERP in Parkinson's disease.

  14. Trial latencies estimation of event-related potentials in EEG by means of genetic algorithms

    Science.gov (United States)

    Da Pelo, P.; De Tommaso, M.; Monaco, A.; Stramaglia, S.; Bellotti, R.; Tangaro, S.

    2018-04-01

    Objective. Event-related potentials (ERPs) are usually obtained by averaging thus neglecting the trial-to-trial latency variability in cognitive electroencephalography (EEG) responses. As a consequence the shape and the peak amplitude of the averaged ERP are smeared and reduced, respectively, when the single-trial latencies show a relevant variability. To date, the majority of the methodologies for single-trial latencies inference are iterative schemes providing suboptimal solutions, the most commonly used being the Woody’s algorithm. Approach. In this study, a global approach is developed by introducing a fitness function whose global maximum corresponds to the set of latencies which renders the trial signals most aligned as possible. A suitable genetic algorithm has been implemented to solve the optimization problem, characterized by new genetic operators tailored to the present problem. Main results. The results, on simulated trials, showed that the proposed algorithm performs better than Woody’s algorithm in all conditions, at the cost of an increased computational complexity (justified by the improved quality of the solution). Application of the proposed approach on real data trials, resulted in an increased correlation between latencies and reaction times w.r.t. the output from RIDE method. Significance. The above mentioned results on simulated and real data indicate that the proposed method, providing a better estimate of single-trial latencies, will open the way to more accurate study of neural responses as well as to the issue of relating the variability of latencies to the proper cognitive and behavioural correlates.

  15. An event-related potential study of working memory in children

    Institute of Scientific and Technical Information of China (English)

    LIU Rong; GUO Chunyan; JIANG Yang

    2006-01-01

    To examine the neural mechanisms of working memory in children, event-related potentials (ERPs) were recorded from the 12―13 year-old while they performed a delayed match-to-sample task. The ERP results revealed that new and studied objects both evoked a late positive ERP component peaking around 350 ms during the working memory process. New objects evoke a more positive ERP waveform than the studied objects. The scalp distribution showed that the frontal-central electrode sites were associated with object working memory processes. When tracking new or studied targets among visual distracters, ERPs of targets and distracters revealed differential responses as early as 150 ms. The visual targets evoked larger and more positive ERP responses than the distracters. The typical old-new effect was observed between ERPs of studied and new distracters. However, ERPs of new and studied targets differed at about 250 ms, in which new targets evoked more positive-going and slightly earlier ERP responses. In addition, a P3a component was found for new targets only, and was absent in ERPs of studied targets at frontal and central sites. The present study results reveal the spatial and temporal characteristics of neural mechanisms underlying working memory in children, some of which are distinct from those in adults.

  16. Discrepancy of neural response between exogenous and endogenous task switching: an event-related potentials study.

    Science.gov (United States)

    Miyajima, Maki; Toyomaki, Atsuhito; Hashimoto, Naoki; Kusumi, Ichiro; Murohashi, Harumitsu; Koyama, Tsukasa

    2012-08-01

    Task switching is a well-known cognitive paradigm to explore task-set reconfiguration processes such as rule shifting. In particular, endogenous task switching is thought to differ qualitatively from stimulus-triggered exogenous task switching. However, no previous study has examined the neural substrate of endogenous task switching. The purpose of the present study is to explore the differences between event-related potential responses to exogenous and endogenous rule switching at cue stimulus. We modified two patterns of cued switching tasks: exogenous (bottom-up) rule switching and endogenous (top-down) rule switching. In each task cue stimulus was configured to induce switching or maintaining rule. In exogenous switching tasks, late positive deflection was larger in the switch rule condition than in the maintain rule condition. However, in endogenous switching tasks late positive deflection was unexpectedly larger in the maintain-rule condition than in the switch-rule condition. These results indicate that exogenous rule switching is explicit stimulus-driven processes, whereas endogenous rule switching is implicitly parallel processes independent of external stimulus.

  17. How culture gets embrained: Cultural differences in event-related potentials of social norm violations.

    Science.gov (United States)

    Mu, Yan; Kitayama, Shinobu; Han, Shihui; Gelfand, Michele J

    2015-12-15

    Humans are unique among all species in their ability to develop and enforce social norms, but there is wide variation in the strength of social norms across human societies. Despite this fundamental aspect of human nature, there has been surprisingly little research on how social norm violations are detected at the neurobiological level. Building on the emerging field of cultural neuroscience, we combine noninvasive electroencephalography (EEG) with a new social norm violation paradigm to examine the neural mechanisms underlying the detection of norm violations and how they vary across cultures. EEG recordings from Chinese and US participants (n = 50) showed consistent negative deflection of event-related potential around 400 ms (N400) over the central and parietal regions that served as a culture-general neural marker of detecting norm violations. The N400 at the frontal and temporal regions, however, was only observed among Chinese but not US participants, illustrating culture-specific neural substrates of the detection of norm violations. Further, the frontal N400 predicted a variety of behavioral and attitudinal measurements related to the strength of social norms that have been found at the national and state levels, including higher culture superiority and self-control but lower creativity. There were no cultural differences in the N400 induced by semantic violation, suggesting a unique cultural influence on social norm violation detection. In all, these findings provided the first evidence, to our knowledge, for the neurobiological foundations of social norm violation detection and its variation across cultures.

  18. Auditory event-related potentials associated with perceptual reversals of bistable pitch motion.

    Science.gov (United States)

    Davidson, Gray D; Pitts, Michael A

    2014-01-01

    Previous event-related potential (ERP) experiments have consistently identified two components associated with perceptual transitions of bistable visual stimuli, the "reversal negativity" (RN) and the "late positive complex" (LPC). The RN (~200 ms post-stimulus, bilateral occipital-parietal distribution) is thought to reflect transitions between neural representations that form the moment-to-moment contents of conscious perception, while the LPC (~400 ms, central-parietal) is considered an index of post-perceptual processing related to accessing and reporting one's percept. To explore the generality of these components across sensory modalities, the present experiment utilized a novel bistable auditory stimulus. Pairs of complex tones with ambiguous pitch relationships were presented sequentially while subjects reported whether they perceived the tone pairs as ascending or descending in pitch. ERPs elicited by the tones were compared according to whether perceived pitch motion changed direction or remained the same across successive trials. An auditory reversal negativity (aRN) component was evident at ~170 ms post-stimulus over bilateral fronto-central scalp locations. An auditory LPC component (aLPC) was evident at subsequent latencies (~350 ms, fronto-central distribution). These two components may be auditory analogs of the visual RN and LPC, suggesting functionally equivalent but anatomically distinct processes in auditory vs. visual bistable perception.

  19. Brain Signals of Face Processing as Revealed by Event-Related Potentials

    Directory of Open Access Journals (Sweden)

    Ela I. Olivares

    2015-01-01

    Full Text Available We analyze the functional significance of different event-related potentials (ERPs as electrophysiological indices of face perception and face recognition, according to cognitive and neurofunctional models of face processing. Initially, the processing of faces seems to be supported by early extrastriate occipital cortices and revealed by modulations of the occipital P1. This early response is thought to reflect the detection of certain primary structural aspects indicating the presence grosso modo of a face within the visual field. The posterior-temporal N170 is more sensitive to the detection of faces as complex-structured stimuli and, therefore, to the presence of its distinctive organizational characteristics prior to within-category identification. In turn, the relatively late and probably more rostrally generated N250r and N400-like responses might respectively indicate processes of access and retrieval of face-related information, which is stored in long-term memory (LTM. New methods of analysis of electrophysiological and neuroanatomical data, namely, dynamic causal modeling, single-trial and time-frequency analyses, are highly recommended to advance in the knowledge of those brain mechanisms concerning face processing.

  20. Individual differences in the recognition of facial expressions: an event-related potentials study.

    Directory of Open Access Journals (Sweden)

    Yoshiyuki Tamamiya

    Full Text Available Previous studies have shown that early posterior components of event-related potentials (ERPs are modulated by facial expressions. The goal of the current study was to investigate individual differences in the recognition of facial expressions by examining the relationship between ERP components and the discrimination of facial expressions. Pictures of 3 facial expressions (angry, happy, and neutral were presented to 36 young adults during ERP recording. Participants were asked to respond with a button press as soon as they recognized the expression depicted. A multiple regression analysis, where ERP components were set as predictor variables, assessed hits and reaction times in response to the facial expressions as dependent variables. The N170 amplitudes significantly predicted for accuracy of angry and happy expressions, and the N170 latencies were predictive for accuracy of neutral expressions. The P2 amplitudes significantly predicted reaction time. The P2 latencies significantly predicted reaction times only for neutral faces. These results suggest that individual differences in the recognition of facial expressions emerge from early components in visual processing.

  1. EEG Channel Selection Using Particle Swarm Optimization for the Classification of Auditory Event-Related Potentials

    Directory of Open Access Journals (Sweden)

    Alejandro Gonzalez

    2014-01-01

    Full Text Available Brain-machine interfaces (BMI rely on the accurate classification of event-related potentials (ERPs and their performance greatly depends on the appropriate selection of classifier parameters and features from dense-array electroencephalography (EEG signals. Moreover, in order to achieve a portable and more compact BMI for practical applications, it is also desirable to use a system capable of accurate classification using information from as few EEG channels as possible. In the present work, we propose a method for classifying P300 ERPs using a combination of Fisher Discriminant Analysis (FDA and a multiobjective hybrid real-binary Particle Swarm Optimization (MHPSO algorithm. Specifically, the algorithm searches for the set of EEG channels and classifier parameters that simultaneously maximize the classification accuracy and minimize the number of used channels. The performance of the method is assessed through offline analyses on datasets of auditory ERPs from sound discrimination experiments. The proposed method achieved a higher classification accuracy than that achieved by traditional methods while also using fewer channels. It was also found that the number of channels used for classification can be significantly reduced without greatly compromising the classification accuracy.

  2. Identifying the null subject: evidence from event-related brain potentials.

    Science.gov (United States)

    Demestre, J; Meltzer, S; García-Albea, J E; Vigil, A

    1999-05-01

    Event-related brain potentials (ERPs) were recorded during spoken language comprehension to study the on-line effects of gender agreement violations in controlled infinitival complements. Spanish sentences were constructed in which the complement clause contained a predicate adjective marked for syntactic gender. By manipulating the gender of the antecedent (i.e., the controller) of the implicit subject while holding constant the gender of the adjective, pairs of grammatical and ungrammatical sentences were created. The detection of such a gender agreement violation would indicate that the parser had established the coreference relation between the null subject and its antecedent. The results showed a complex biphasic ERP (i.e., an early negativity with prominence at anterior and central sites, followed by a centroparietal positivity) in the violating condition as compared to the non-violating conditions. The brain reacts to NP-adjective gender agreement violations within a few hundred milliseconds of their occurrence. The data imply that the parser has properly coindexed the null subject of an infinitive clause with its antecedent.

  3. Feedback processing in adolescence: an event-related potential study of age and gender differences.

    Science.gov (United States)

    Grose-Fifer, Jillian; Migliaccio, Renee; Zottoli, Tina M

    2014-01-01

    Adolescence has frequently been characterized as a period of increased risk taking, which may be largely driven by maturational changes in neural areas that process incentives. To investigate age- and gender-related differences in reward processing, we recorded event-related potentials (ERPs) from 80 participants in a gambling game, in which monetary wins and losses were either large or small. We measured two ERP components: the feedback-related negativity (FRN) and the feedback P3 (fP3). The FRN was sensitive to the size of a win in both adult (aged 23-35 years) and adolescent (aged 13-17 years) males, but not in females. Small wins appeared to be less rewarding for males than for females, which may in part explain more approach-driven behavior in males in general. Furthermore, adolescent boys showed both delayed FRNs to high losses and less differentiation in FRN amplitude between wins and losses in comparison to girls. The fP3, which is thought to index the salience of the feedback at a more conscious level than the FRN, was also larger in boys than in girls. Taken together, these results imply that higher levels of risk taking that are commonly reported in adolescent males may be driven both by hypersensitivity to high rewards and insensitivity to punishment or losses. © 2014 S. Karger AG, Basel.

  4. Event-related potentials elicited by social commerce and electronic-commerce reviews.

    Science.gov (United States)

    Bai, Yan; Yao, Zhong; Cong, Fengyu; Zhang, Linlin

    2015-12-01

    There is an increasing interest regarding the use of electroencephalography (EEG) in social commerce and electronic commerce (e-commerce) research. There are several reviews in the field of social commerce or e-commerce; these have great potential value and mining them is fundamental and significant. To our knowledge, EEG is rarely applied to study these. In this study, we examined the neural correlates of social commerce reviews (SCRs) and e-commerce reviews (ECRs) by using them as stimuli to evoke event-related potentials. All SCRs were from friends through a social media platform, whereas ECRs were from strangers through an e-commerce platform. The experimental design was similar to that of a priming paradigm, and included 40 pairs of stimuli consisting of product information (prime stimulus) and reviews (target stimulus). The results showed that the P300 component was successfully evoked by SCR and ECR stimuli. Moreover, the P300 components elicited by SCRs had higher amplitudes than those elicited by ECRs. These findings indicate that participants paid more attention to SCRs than to ECRs. In addition, the associations between neural responses and reviews in social commerce have the potential to assist companies in studying consumer behaviors, thus permitting them to enhance their social commerce strategies.

  5. The impact of perceived quality on online buying decisions: an event-related potentials perspective.

    Science.gov (United States)

    Wang, Jing; Han, Weiwei

    2014-10-01

    Consumer neuroscience can provide useful insights into the neural foundations of consumer decisions, such as perceived quality. One of the applications is to guide attribute configuration of products to fit consumers' expectations on the basis of individual preferences. In this study, we required 20 participants to decide whether to buy the product provided in the stimuli and to respond as soon as possible. According to their reports of expectations after the experiment, we subdivided the stimuli into two conditions. Condition 1 contained the stimuli that fit individual preferences, whereas Condition 2 contained the other stimuli. An essential component of event-related potentials (ERPs), the P300, was elicited in the two conditions and distributed over almost all parietal and occipital regions. Products in Condition 1 induced a higher P300 amplitude than those in Condition 2. The results show that evaluating product attributes is a cognitive process that modulates attention in the aforementioned regions. When participants evaluate the alternatives, categorical processing occurred on the basis of similarity judgment. The situation in Condition 1 produced a similarity overlap between the product and the expectation and resulted in a higher P300. Otherwise, there was no overlap, leading to a smaller P300. Hence, the P300 may be a useful neural endogenous indicator for measuring consumers' evaluations of products in marketing research.

  6. Event-related potentials and secondary task performance during simulated driving.

    Science.gov (United States)

    Wester, A E; Böcker, K B E; Volkerts, E R; Verster, J C; Kenemans, J L

    2008-01-01

    Inattention and distraction account for a substantial number of traffic accidents. Therefore, we examined the impact of secondary task performance (an auditory oddball task) on a primary driving task (lane keeping). Twenty healthy participants performed two 20-min tests in the Divided Attention Steering Simulator (DASS). The visual secondary task of the DASS was replaced by an auditory oddball task to allow recording of brain activity. The driving task and the secondary (distracting) oddball task were presented in isolation and simultaneously, to assess their mutual interference. In addition to performance measures (lane keeping in the primary driving task and reaction speed in the secondary oddball task), brain activity, i.e. event-related potentials (ERPs), was recorded. Performance parameters on the driving test and the secondary oddball task did not differ between performance in isolation and simultaneous performance. However, when both tasks were performed simultaneously, reaction time variability increased in the secondary oddball task. Analysis of brain activity indicated that ERP amplitude (P3a amplitude) related to the secondary task, was significantly reduced when the task was performed simultaneously with the driving test. This study shows that when performing a simple secondary task during driving, performance of the driving task and this secondary task are both unaffected. However, analysis of brain activity shows reduced cortical processing of irrelevant, potentially distracting stimuli from the secondary task during driving.

  7. Relationship between early and late stages of information processing: an event-related potential study

    Science.gov (United States)

    Portella, Claudio; Machado, Sergio; Arias-Carrión, Oscar; Sack, Alexander T.; Silva, Julio Guilherme; Orsini, Marco; Leite, Marco Antonio Araujo; Silva, Adriana Cardoso; Nardi, Antonio E.; Cagy, Mauricio; Piedade, Roberto; Ribeiro, Pedro

    2012-01-01

    The brain is capable of elaborating and executing different stages of information processing. However, exactly how these stages are processed in the brain remains largely unknown. This study aimed to analyze the possible correlation between early and late stages of information processing by assessing the latency to, and amplitude of, early and late event-related potential (ERP) components, including P200, N200, premotor potential (PMP) and P300, in healthy participants in the context of a visual oddball paradigm. We found a moderate positive correlation among the latency of P200 (electrode O2), N200 (electrode O2), PMP (electrode C3), P300 (electrode PZ) and the reaction time (RT). In addition, moderate negative correlation between the amplitude of P200 and the latencies of N200 (electrode O2), PMP (electrode C3), P300 (electrode PZ) was found. Therefore, we propose that if the secondary processing of visual input (P200 latency) occurs faster, the following will also happen sooner: discrimination and classification process of this input (N200 latency), motor response processing (PMP latency), reorganization of attention and working memory update (P300 latency), and RT. N200, PMP, and P300 latencies are also anticipated when higher activation level of occipital areas involved in the secondary processing of visual input rise (P200 amplitude). PMID:23355929

  8. Rapid L2 Word Learning through High Constraint Sentence Context: An Event-Related Potential Study

    Directory of Open Access Journals (Sweden)

    Baoguo Chen

    2017-12-01

    Full Text Available Previous studies have found quantity of exposure, i.e., frequency of exposure (Horst et al., 1998; Webb, 2008; Pellicer-Sánchez and Schmitt, 2010, is important for second language (L2 contextual word learning. Besides this factor, context constraint and L2 proficiency level have also been found to affect contextual word learning (Pulido, 2003; Tekmen and Daloglu, 2006; Elgort et al., 2015; Ma et al., 2015. In the present study, we adopted the event-related potential (ERP technique and chose high constraint sentences as reading materials to further explore the effects of quantity of exposure and proficiency on L2 contextual word learning. Participants were Chinese learners of English with different English proficiency levels. For each novel word, there were four high constraint sentences with the critical word at the end of the sentence. Learners read sentences and made semantic relatedness judgment afterwards, with ERPs recorded. Results showed that in the high constraint condition where each pseudoword was embedded in four sentences with consistent meaning, N400 amplitude upon this pseudoword decreased significantly as learners read the first two sentences. High proficiency learners responded faster in the semantic relatedness judgment task. These results suggest that in high quality sentence contexts, L2 learners could rapidly acquire word meaning without multiple exposures, and L2 proficiency facilitated this learning process.

  9. ERPLAB: An Open-Source Toolbox for the Analysis of Event-Related Potentials

    Directory of Open Access Journals (Sweden)

    Javier eLopez-Calderon

    2014-04-01

    Full Text Available ERPLAB Toolbox is a freely available, open-source toolbox for processing and analyzing event-related potential (ERP data in the MATLAB environment. ERPLAB is closely integrated with EEGLAB, a popular open-source toolbox that provides many EEG preprocessing steps and an excellent user interface design. ERPLAB adds to EEGLAB’s EEG processing functions, providing additional tools for filtering, artifact detection, re-referencing, and sorting of events, among others. ERPLAB also provides robust tools for averaging EEG segments together to create averaged ERPs, for creating difference waves and other recombinations of ERP waveforms through algebraic expressions, for filtering and re-referencing the averaged ERPs, for plotting ERP waveforms and scalp maps, and for quantifying several types of amplitudes and latencies. ERPLAB’s tools can be accessed either from an easy-to-learn graphical user interface or from MATLAB scripts, and a command history function makes it easy for users with no programming experience to write scripts. Consequently, ERPLAB provides both ease of use and virtually unlimited power and flexibility, making it appropriate for the analysis of both simple and complex ERP experiments. Several forms of documentation are available, including a detailed user’s guide, a step-by-step tutorial, a scripting guide, and a set of video-based demonstrations.

  10. Social distance influences the outcome evaluation of cooperation and conflict: Evidence from event-related potentials.

    Science.gov (United States)

    Chen, Yezi; Lu, Jiamei; Wang, Yiwen; Feng, Zhouqi; Yuan, Bo

    2017-04-24

    Previous research shows that social distance plays an important role in promoting cooperation and that subtle cues that reduce social distance increase the tendency to cooperate. However, it is unclear how social distance influences our outcome evaluation of cooperative and conflict feedback. The present study investigated the influence of social distance on cooperative and conflict behavior and the evaluation process of the cooperative and conflict outcomes, using the event-related potentials (ERPs) technique. We recorded ERPs from 14 normal adults playing a social game task against a friend and a stranger. The results showed that the FRN (Feedback Related Negativity) and P300 were affected by the opponent's choice to cooperate or aggress; however, only the P300 was affected by social distance. Specifically, when the opponent chose to cooperate, the feedback elicited a smaller FRN and a larger P300 amplitude; and compared with playing against friends, the P300 had a larger amplitude when participants gaming with strangers. Our results indicate that at the early stage of the evaluation of cooperation and conflict outcomes, individuals may initially and quickly encode the valence of outcomes, judging whether an outcome is consistent with their expectations. However, at the late stage, which involves a top-down cognitive appraisal process, some social factors, such as social distance, may moderate processing of attention resource allocation of feedback about outcomes, and of higher-level motivation/affective appraisal. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Event-Related Potential Patterns Associated with Hyperarousal in Gulf War Illness Syndrome Groups

    Science.gov (United States)

    Tillman, Gail D.; Calley, Clifford S.; Green, Timothy A.; Buhl, Virginia I.; Biggs, Melanie M.; Spence, Jeffrey S.; Briggs, Richard W.; Haley, Robert W.; Hart, John; Kraut, Michael A.

    2012-01-01

    An exaggerated response to emotional stimuli is one of several symptoms widely reported by veterans of the 1991 Persian Gulf War. Many have attributed these symptoms to post-war stress; others have attributed the symptoms to deployment-related exposures and associated damage to cholinergic, dopaminergic, and white matter systems. We collected event-related potential (ERP) data from 20 veterans meeting Haley criteria for Gulf War Syndromes 1–3 and from 8 matched Gulf War veteran controls, who were deployed but not symptomatic, while they performed an auditory three-condition oddball task with gunshot and lion roar sounds as the distractor stimuli. Reports of hyperarousal from the ill veterans were significantly greater than those from the control veterans; different ERP profiles emerged to account for their hyperarousability. Syndromes 2 and 3, who have previously shown brainstem abnormalities, show significantly stronger auditory P1 amplitudes, purported to indicate compromised cholinergic inhibitory gating in the reticular activating system. Syndromes 1 and 2, who have previously shown basal ganglia dysfunction, show significantly weaker P3a response to distractor stimuli, purported to indicate dysfunction of the dopaminergic contribution to their ability to inhibit distraction by irrelevant stimuli. All three syndrome groups showed an attenuated P3b to target stimuli, which could be secondary to both cholinergic and dopaminergic contributions or disruption of white matter integrity. PMID:22691951

  12. Event Related Potentials and Serial List Picture Memory in Parkinson’s Patients

    Directory of Open Access Journals (Sweden)

    M. S. Korsnes

    1996-01-01

    Full Text Available Two experiments examined short-term memory for order information in six patients diagnosed with Parkinson's disease (PD and six control subjects while event related potentials (ERPs were recorded. The subjects were tested for recognition of abstract spatial designs and words after a 5 s retention interval. The PD patients failed to respond in 29% of all trials, but the overall accuracy was similar to that in the control group when these trials were excluded. The corresponding ERP results show serial position variations both after presentation of the probe items, and after presentation of the memory set items. The amplitudes were generally lower at all positions for the PD patients at the parietal midline electrode, and the amplitudes were similar for both groups at the frontal electrode. Also, the ERP latencies were significantly slower for the PD patients than for the control group at all conditions. Indirectly the data are consistent with an interpretation of cognitive deficit in PD stressing attention resources.

  13. Subclinical alexithymia modulates early audio-visual perceptive and attentional event-related potentials

    Directory of Open Access Journals (Sweden)

    Dyna eDelle-Vigne

    2014-03-01

    Full Text Available Introduction:Previous studies have highlighted the advantage of audio–visual oddball tasks (instead of unimodal ones in order to electrophysiologically index subclinical behavioral differences. Since alexithymia is highly prevalent in the general population, we investigated whether the use of various bimodal tasks could elicit emotional effects in low- versus high-alexithymic scorers. Methods:Fifty students (33 females were split into groups based on low and high scores on the Toronto Alexithymia Scale. During event-related potential recordings, they were exposed to three kinds of audio–visual oddball tasks: neutral (geometrical forms and bips, animal (dog and cock with their respective shouts, or emotional (faces and voices stimuli. In each condition, participants were asked to quickly detect deviant events occurring amongst a train of frequent matching stimuli (e.g., push a button when a sad face–voice pair appeared amongst a train of neutral face–voice pairs. P100, N100, and P300 components were analyzed: P100 refers to visual perceptive processing, N100 to auditory ones, and the P300 relates to response-related stages. Results:High-alexithymic scorers presented a particular pattern of results when processing the emotional stimulations, reflected in early ERP components by increased P100 and N100 amplitudes in the emotional oddball tasks (P100: pConclusions:Our findings suggest that high-alexithymic scorers require heightened early attentional resources when confronted with emotional stimuli.

  14. Cognitive deficits in amyotrophic lateral sclerosis evaluated by event-related potentials.

    Science.gov (United States)

    Ogawa, Tomohiro; Tanaka, Hideaki; Hirata, Koichi

    2009-04-01

    To determine the cognitive profiles in non-demented, relatively less handicapped patients with early-stage sporadic amyotrophic lateral sclerosis (ALS) by using neuropsychological tests, event-related potentials (ERPs) and clinical scale. We recruited 19 patients with sporadic ALS (eight with limb-onset, 11 with bulbar-onset) and 19 controls. In addition to the mini-mental state examination and the Wechsler adult intelligence scale-revised, we assessed the frontal lobe function with Wisconsin card sorting test, Stroop test and trail making test. We used auditory 'oddball' counting paradigm for the ERPs under 20-channel electroencephalogram (EEG) recording. Global field power (GFP) was computed, and its peak amplitudes and latencies of N1/N2/P3 were determined. The results of ERP and neuropsychological tests were correlated with respiratory function and clinical scale. No global cognitive impairment except for subtle frontal dysfunction was detected, although N1/N2/P3 GFP latencies were significantly prolonged in ALS patients than in the controls. Vital capacity correlated with P3 GFP amplitude, and the relative bulbar functional rating scale correlated with P3 GFP latency. Our findings indicated the presence of sub-clinical cognitive deficits in non-demented, sporadic ALS patients. In addition, clinical sub-types and respiratory function dependently influenced cognitive function in patients with sporadic ALS. ERP confirmed cognitive impairment in patients with sporadic ALS.

  15. Sex differences in humor processing: An event-related potential study.

    Science.gov (United States)

    Chang, Yi-Tzu; Ku, Li-Chuan; Chen, Hsueh-Chih

    2018-02-01

    Numerous behavioral studies and a handful of functional neuroimaging studies have reported sex differences in humor. However, no study to date has examined differences in the time-course of brain activity during multistage humor processing between the sexes. The purpose of this study was to compare real-time dynamics related to humor processing between women and men, with reference to a proposed three-stage model (involving incongruity detection, incongruity resolution, and elaboration stages). Forty undergraduate students (20 women) underwent event-related potential recording while subjectively rating 30 question-answer-type jokes and 30 question-answer-type statements in a random order. Sex differences were revealed by analyses of the mean amplitudes of difference waves during a specific time window between 1000 and 1300 ms poststimulus onset (P1000-1300). This indicates that women recruited more mental resources to integrate cognitive and emotional components at this late stage. In contrast, men recruited more automated processes during the transition from the cognitive operations of the incongruity resolution stage to the emotional response of the humor elaboration stage. Our results suggest that sex differences in humor processing lie in differences in the integration of cognitive and emotional components, which are closely linked and interact reciprocally, particularly in women. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. Person perception precedes theory of mind: an event related potential analysis.

    Science.gov (United States)

    Wang, Y W; Lin, C D; Yuan, B; Huang, L; Zhang, W X; Shen, D L

    2010-09-29

    Prior to developing an understanding of another person's mental state, an ability termed "theory of mind" (ToM), a perception of that person's appearance and actions is required. However the relationship between this "person perception" and ToM is unclear. To investigate the time course of ToM and person perception, event-related potentials (ERP) were recorded while 17 normal adults received three kinds of visual stimuli: cartoons involving people (person perception cartoons), cartoons involving people and also requiring ToM for comprehension (ToM cartoons), and scene cartoons. We hypothesized that the respective patterns of brain activation would be different under these three stimuli, at different stages in time. Our findings supported this proposal: the peak amplitudes of P200 for scene cartoons were significantly lower than for person perception or ToM cartoons, while there were no significant differences between the latter two for P200. During the 1000-1300 ms epoch, the mean amplitudes of the late positive components (LPC) for person perception were more positive than for scene representation, while the mean amplitudes of the LPC for ToM were more positive than for person perception. The present study provides preliminary evidence of the neural dynamic that underlies the dissociation between person perception and ToM. Copyright 2010 IBRO. Published by Elsevier Ltd. All rights reserved.

  17. Antiherding in Financial Decision Increases Valuation of Return on Investment: An Event-Related Potential Study

    Directory of Open Access Journals (Sweden)

    Cuicui Wang

    2017-01-01

    Full Text Available Using event-related potentials, this study investigated how financial herding or antiherding affected the valuation of subsequent outcomes. For each trial, subjects decided whether to buy the stock according to its net money flow information which could be used to reflect the strength of buying power or selling power of the stock. The return on investment (ROI as feedback included the increase or decrease percentage after subjects’ responses. Results showed that, compared with herding, antiherding induced larger discrepancies of FRN and P300 amplitude between positive ROI and negative ROI, indicating that individuals under antiherding condition had stronger motivation and paid more attention in the evaluation process of ROI. Moreover, only for positive ROI, the amplitudes of FRN and P300 were modulated by two kinds of behaviors. We suggested that individuals making antiherd decisions were more confident with their own ability and choices, which reduced the positive outcome prediction error and gave more mental resources to evaluate positive outcome. However, negative outcomes evoked no different motivational meaning and negative emotion for individuals between herding and antiherding. The study may provide new insights into neurocognitive processes of herding and antiherding in financial market.

  18. An event-related potential study on the interaction between lighting level and stimulus spatial location

    Directory of Open Access Journals (Sweden)

    Luis eCarretié

    2015-11-01

    Full Text Available Due to heterogeneous photoreceptor distribution, spatial location of stimulation is crucial to study visual brain activity in different light environments. This unexplored issue was studied through occipital event-related potentials (ERPs recorded from 40 participants in response to discrete visual stimuli presented at different locations and in two environmental light conditions, low mesopic (L, 0.03 lux and high mesopic (H, 6.5 lux, characterized by a differential photoreceptor activity balance: rod>cone and rod

  19. Negativity bias for sad faces in depression: An event-related potential study.

    Science.gov (United States)

    Dai, Qin; Wei, Juanjuan; Shu, Xiaorui; Feng, Zhengzhi

    2016-12-01

    Negativity bias in depression has been previously confirmed. However, mainly during a valence category task, it remains unclear how happy or unhappy individuals perceive emotional materials. Moreover, cerebral alteration measurements during a valence judgment task is lacking. The present study aimed to explore a valence judgment of a valence rating task, combined with event-related potential (ERP) recording. Healthy controls, individuals with sub-clinical depression, and patients diagnosed with major depressive disorder (MDD) were recruited. Twenty-four subjects in each group completed a valence rating task, during which the ERP amplitudes were recorded. The MDD group had lower valence scores, faster responses, and greater N1 amplitudes for sad faces, whereas individuals with sub-clinical depression had faster responses and greater P1 amplitudes for all faces but lower valence scores and greater P2 amplitudes for happy faces. The findings suggest the tendency toward a negativity bias in valence ratings in patients with depression supported by behavioral and cerebral evidence, which is a latent trait of depression, possibly associated with the vulnerability of depression. The current study offers the first experimental evidence of cognitive and cerebral biomarkers of negativity bias in valence ratings in depression, which confirms Beck's cognitive theory and gives important direction for clinical therapy. Copyright © 2016 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  20. Analysis of events related to cracks and leaks in the reactor coolant pressure boundary

    Energy Technology Data Exchange (ETDEWEB)

    Ballesteros, Antonio, E-mail: Antonio.Ballesteros-Avila@ec.europa.eu [JRC-IET: Institute for Energy and Transport of the Joint Research Centre of the European Commission, Postbus 2, NL-1755 ZG Petten (Netherlands); Sanda, Radian; Peinador, Miguel; Zerger, Benoit [JRC-IET: Institute for Energy and Transport of the Joint Research Centre of the European Commission, Postbus 2, NL-1755 ZG Petten (Netherlands); Negri, Patrice [IRSN: Institut de Radioprotection et de Sûreté Nucléaire (France); Wenke, Rainer [GRS: Gesellschaft für Anlagen- und Reaktorsicherheit (GRS) mbH (Germany)

    2014-08-15

    Highlights: • The important role of Operating Experience Feedback is emphasised. • Events relating to cracks and leaks in the reactor coolant pressure boundary are analysed. • A methodology for event investigation is described. • Some illustrative results of the analysis of events for specific components are presented. - Abstract: The presence of cracks and leaks in the reactor coolant pressure boundary may jeopardise the safe operation of nuclear power plants. Analysis of cracks and leaks related events is an important task for the prevention of their recurrence, which should be performed in the context of activities on Operating Experience Feedback. In response to this concern, the EU Clearinghouse operated by the JRC-IET supports and develops technical and scientific work to disseminate the lessons learned from past operating experience. In particular, concerning cracks and leaks, the studies carried out in collaboration with IRSN and GRS have allowed to identify the most sensitive areas to degradation in the plant primary system and to elaborate recommendations for upgrading the maintenance, ageing management and inspection programmes. An overview of the methodology used in the analysis of cracks and leaks related events is presented in this paper, together with the relevant results obtained in the study.

  1. Sex differences and emotion regulation: an event-related potential study.

    Directory of Open Access Journals (Sweden)

    Elyse K T Gardener

    Full Text Available Difficulties in emotion regulation have been implicated as a potential mechanism underlying anxiety and mood disorders. It is possible that sex differences in emotion regulation may contribute towards the heightened female prevalence for these disorders. Previous fMRI studies of sex differences in emotion regulation have shown mixed results, possibly due to difficulties in discriminating the component processes of early emotional reactivity and emotion regulation. The present study used event-related potentials (ERPs to examine sex differences in N1 and N2 components (reflecting early emotional reactivity and P3 and LPP components (reflecting emotion regulation. N1, N2, P3, and LPP were recorded from 20 men and 23 women who were instructed to "increase," "decrease," and "maintain" their emotional response during passive viewing of negative images. Results indicated that women had significantly greater N1 and N2 amplitudes (reflecting early emotional reactivity to negative stimuli than men, supporting a female negativity bias. LPP amplitudes increased to the "increase" instruction, and women displayed greater LPP amplitudes than men to the "increase" instruction. There were no differences to the "decrease" instruction in women or men. These findings confirm predictions of the female negativity bias hypothesis and suggest that women have greater up-regulation of emotional responses to negative stimuli. This finding is highly significant in light of the female vulnerability for developing anxiety disorders.

  2. Sex differences and emotion regulation: an event-related potential study.

    Science.gov (United States)

    Gardener, Elyse K T; Carr, Andrea R; Macgregor, Amy; Felmingham, Kim L

    2013-01-01

    Difficulties in emotion regulation have been implicated as a potential mechanism underlying anxiety and mood disorders. It is possible that sex differences in emotion regulation may contribute towards the heightened female prevalence for these disorders. Previous fMRI studies of sex differences in emotion regulation have shown mixed results, possibly due to difficulties in discriminating the component processes of early emotional reactivity and emotion regulation. The present study used event-related potentials (ERPs) to examine sex differences in N1 and N2 components (reflecting early emotional reactivity) and P3 and LPP components (reflecting emotion regulation). N1, N2, P3, and LPP were recorded from 20 men and 23 women who were instructed to "increase," "decrease," and "maintain" their emotional response during passive viewing of negative images. Results indicated that women had significantly greater N1 and N2 amplitudes (reflecting early emotional reactivity) to negative stimuli than men, supporting a female negativity bias. LPP amplitudes increased to the "increase" instruction, and women displayed greater LPP amplitudes than men to the "increase" instruction. There were no differences to the "decrease" instruction in women or men. These findings confirm predictions of the female negativity bias hypothesis and suggest that women have greater up-regulation of emotional responses to negative stimuli. This finding is highly significant in light of the female vulnerability for developing anxiety disorders.

  3. Alcohol Preferences and Event-Related Potentials to Alcohol Images in College Students.

    Science.gov (United States)

    Thurin, Kyle; Ceballos, Natalie A; Graham, Reiko

    2017-11-01

    Research on attentional biases to alcohol images has used heterogeneous sets of stimuli (e.g., an isolated beer can or a group of people drinking). However, alcoholic beverage preferences play an important part in determining an individual's alcohol use pattern and may influence attentional biases, especially for inexperienced drinkers. The current study examined whether alcoholic beverage preferences affect event-related potential (ERP) indices of cue reactivity to different types of alcohol images (e.g., beer, wine, and distilled spirits) in heavy episodic drinkers. ERPs were recorded in 14 heavy episodic drinkers (7 male) who completed a Go/No-Go task using preferred and nonpreferred alcohol images with nonalcoholic beverage images as controls. Larger N2 amplitudes for preferred alcohol images were observed relative to control images and to nonpreferred alcohol images, indicating increased attentional capture by preferred beverages. P3 amplitudes and latencies were not sensitive to preferences, but latencies were delayed and amplitudes were enhanced on No-Go trials (i.e., trials requiring response inhibition). These results suggest that alcoholic beverage preference is a factor influencing alcohol cue reactivity in heavy-episodic-drinking college students. This information has methodological significance and may also be applied to improve treatment and prevention programs that focus on attentional bias modification and inhibitory control training.

  4. Neural Temporal Dynamics of Social Exclusion Elicited by Averted Gaze: An Event-Related Potentials Study

    Directory of Open Access Journals (Sweden)

    Yue Leng

    2018-02-01

    Full Text Available Eye gaze plays a fundamental role in social communication. The averted eye gaze during social interaction, as the most common form of silent treatment, conveys a signal of social exclusion. In the present study, we examined the time course of brain response to social exclusion by using a modified version of Eye-gaze paradigm. The event-related potentials (ERPs data and the subjective rating data showed that the frontocentral P200 was positively correlated with negative mood of excluded events, whereas, the centroparietal late positive potential (LPP was positively correlated with the perceived ostracism intensity. Both the P200 and LPP were more positive-going for excluded events than for included events. These findings suggest that brain responses sensitive to social exclusion can be divided into the early affective processing stage, linking to the early pre-cognitive warning system; and the late higher-order processes stage, demanding attentional resources for elaborate stimuli evaluation and categorization generally not under specific situation.

  5. Topic structure affects semantic integration: evidence from event-related potentials.

    Science.gov (United States)

    Yang, Xiaohong; Chen, Xuhai; Chen, Shuang; Xu, Xiaoying; Yang, Yufang

    2013-01-01

    This study investigated whether semantic integration in discourse context could be influenced by topic structure using event-related brain potentials. Participants read discourses in which the last sentence contained a critical word that was either congruent or incongruent with the topic established in the first sentence. The intervening sentences between the first and the last sentence of the discourse either maintained or shifted the original topic. Results showed that incongruent words in topic-maintained discourses elicited an N400 effect that was broadly distributed over the scalp while those in topic-shifted discourses elicited an N400 effect that was lateralized to the right hemisphere and localized over central and posterior areas. Moreover, a late positivity effect was only elicited by incongruent words in topic-shifted discourses, but not in topic-maintained discourses. This suggests an important role for discourse structure in semantic integration, such that compared with topic-maintained discourses, the complexity of discourse structure in topic-shifted condition reduces the initial stage of semantic integration and enhances the later stage in which a mental representation is updated.

  6. Short-term effects of prosocial video games on aggression: an event-related potential study.

    Science.gov (United States)

    Liu, Yanling; Teng, Zhaojun; Lan, Haiying; Zhang, Xin; Yao, Dezhong

    2015-01-01

    Previous research has shown that exposure to violent video games increases aggression, whereas exposure to prosocial video games can reduce aggressive behavior. However, little is known about the neural correlates of these behavioral effects. This work is the first to investigate the electrophysiological features of the relationship between playing a prosocial video game and inhibition of aggressive behavior. Forty-nine subjects played either a prosocial or a neutral video game for 20 min, then participated in an event-related potential (ERP) experiment based on an oddball paradigm and designed to test electrophysiological responses to prosocial and violent words. Finally, subjects completed a competitive reaction time task (CRTT) which based on Taylor's Aggression Paradigm and contains reaction time and noise intensity chosen as a measure of aggressive behavior. The results show that the prosocial video game group (compared to the neutral video game group) displayed smaller P300 amplitudes, were more accurate in distinguishing violent words, and were less aggressive as evaluated by the CRTT of noise intensity chosen. A mediation analysis shows that the P300 amplitude evoked by violent words partially mediates the relationship between type of video game and subsequent aggressive behavior. The results support theories based on the General Learning Model. We provide converging behavioral and neural evidence that exposure to prosocial media may reduce aggression.

  7. Individual differences in the recognition of facial expressions: an event-related potentials study.

    Science.gov (United States)

    Tamamiya, Yoshiyuki; Hiraki, Kazuo

    2013-01-01

    Previous studies have shown that early posterior components of event-related potentials (ERPs) are modulated by facial expressions. The goal of the current study was to investigate individual differences in the recognition of facial expressions by examining the relationship between ERP components and the discrimination of facial expressions. Pictures of 3 facial expressions (angry, happy, and neutral) were presented to 36 young adults during ERP recording. Participants were asked to respond with a button press as soon as they recognized the expression depicted. A multiple regression analysis, where ERP components were set as predictor variables, assessed hits and reaction times in response to the facial expressions as dependent variables. The N170 amplitudes significantly predicted for accuracy of angry and happy expressions, and the N170 latencies were predictive for accuracy of neutral expressions. The P2 amplitudes significantly predicted reaction time. The P2 latencies significantly predicted reaction times only for neutral faces. These results suggest that individual differences in the recognition of facial expressions emerge from early components in visual processing.

  8. Event-related potential effects of superior action anticipation in professional badminton players.

    Science.gov (United States)

    Jin, Hua; Xu, Guiping; Zhang, John X; Gao, Hongwei; Ye, Zuoer; Wang, Pin; Lin, Huiyan; Mo, Lei; Lin, Chong-De

    2011-04-04

    The ability to predict the trajectory of a ball based on the opponent's body kinematics has been shown to be critical to high-performing athletes in many sports. However, little is known about the neural correlates underlying such superior ability in action anticipation. The present event-related potential study compared brain responses from professional badminton players and non-player controls when they watched video clips of badminton games and predicted a ball's landing position. Replicating literature findings, the players made significantly more accurate judgments than the controls and showed better action anticipation. Correspondingly, they showed enlarged amplitudes of two ERP components, a P300 peaking around 350ms post-stimulus with a parietal scalp distribution and a P2 peaking around 250ms with a posterior-occipital distribution. The P300 effect was interpreted to reflect primed access and/or directing of attention to game-related memory representations in the players facilitating their online judgment of related actions. The P2 effect was suggested to reflect some generic learning effects. The results identify clear neural responses that differentiate between different levels of action anticipation associated with sports expertise. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  9. An event-related potential study of maternal love in mothers.

    Science.gov (United States)

    Lu, Jiamei; Li, Da; Xu, Jingwei

    2012-10-01

    Feeling is stable and implicit and can be explicated in concrete situations in the form of emotion. To map the time course of feeling processing, the present study explored electrophysiological responses relevant to inner feeling by creating situations to evoke the explicit response of feeling. Fourteen mothers were asked to listen to TS and NS. Although the early event-related potential components (P1, N1 and P2) elicited by story pictures were not affected by the emotional valence of stories, the pictures relevant to TS elicited larger P3 and late positive potential (LPP) components than did neutral story pictures, indicating that feeling processing occurred at the post-perceptual stage. Feeling-related positive potential was separated using the difference wave analysis technique, which consisted of two sub-components: FRBB1 and FRBB2 based on P3 and LPP modulations, respectively. These data provide new electrophysiological evidence for the time course of feeling processing related to maternal love.

  10. Antiherding in Financial Decision Increases Valuation of Return on Investment: An Event-Related Potential Study.

    Science.gov (United States)

    Wang, Cuicui; Jin, Jia; Vieito, João Paulo; Ma, Qingguo

    2017-01-01

    Using event-related potentials, this study investigated how financial herding or antiherding affected the valuation of subsequent outcomes. For each trial, subjects decided whether to buy the stock according to its net money flow information which could be used to reflect the strength of buying power or selling power of the stock. The return on investment (ROI) as feedback included the increase or decrease percentage after subjects' responses. Results showed that, compared with herding, antiherding induced larger discrepancies of FRN and P300 amplitude between positive ROI and negative ROI, indicating that individuals under antiherding condition had stronger motivation and paid more attention in the evaluation process of ROI. Moreover, only for positive ROI, the amplitudes of FRN and P300 were modulated by two kinds of behaviors. We suggested that individuals making antiherd decisions were more confident with their own ability and choices, which reduced the positive outcome prediction error and gave more mental resources to evaluate positive outcome. However, negative outcomes evoked no different motivational meaning and negative emotion for individuals between herding and antiherding. The study may provide new insights into neurocognitive processes of herding and antiherding in financial market.

  11. Processing statistics: an examination of focused and distributed attention using event related potentials.

    Science.gov (United States)

    Baijal, Shruti; Nakatani, Chie; van Leeuwen, Cees; Srinivasan, Narayanan

    2013-06-07

    Human observers show remarkable efficiency in statistical estimation; they are able, for instance, to estimate the mean size of visual objects, even if their number exceeds the capacity limits of focused attention. This ability has been understood as the result of a distinct mode of attention, i.e. distributed attention. Compared to the focused attention mode, working memory representations under distributed attention are proposed to be more compressed, leading to reduced working memory loads. An alternate proposal is that distributed attention uses less structured, feature-level representations. These would fill up working memory (WM) more, even when target set size is low. Using event-related potentials, we compared WM loading in a typical distributed attention task (mean size estimation) to that in a corresponding focused attention task (object recognition), using a measure called contralateral delay activity (CDA). Participants performed both tasks on 2, 4, or 8 different-sized target disks. In the recognition task, CDA amplitude increased with set size; notably, however, in the mean estimation task the CDA amplitude was high regardless of set size. In particular for set-size 2, the amplitude was higher in the mean estimation task than in the recognition task. The result showed that the task involves full WM loading even with a low target set size. This suggests that in the distributed attention mode, representations are not compressed, but rather less structured than under focused attention conditions. Copyright © 2012 Elsevier Ltd. All rights reserved.

  12. Sensitivity to structure in action sequences: An infant event-related potential study.

    Science.gov (United States)

    Monroy, Claire D; Gerson, Sarah A; Domínguez-Martínez, Estefanía; Kaduk, Katharina; Hunnius, Sabine; Reid, Vincent

    2017-05-06

    Infants are sensitive to structure and patterns within continuous streams of sensory input. This sensitivity relies on statistical learning, the ability to detect predictable regularities in spatial and temporal sequences. Recent evidence has shown that infants can detect statistical regularities in action sequences they observe, but little is known about the neural process that give rise to this ability. In the current experiment, we combined electroencephalography (EEG) with eye-tracking to identify electrophysiological markers that indicate whether 8-11-month-old infants detect violations to learned regularities in action sequences, and to relate these markers to behavioral measures of anticipation during learning. In a learning phase, infants observed an actor performing a sequence featuring two deterministic pairs embedded within an otherwise random sequence. Thus, the first action of each pair was predictive of what would occur next. One of the pairs caused an action-effect, whereas the second did not. In a subsequent test phase, infants observed another sequence that included deviant pairs, violating the previously observed action pairs. Event-related potential (ERP) responses were analyzed and compared between the deviant and the original action pairs. Findings reveal that infants demonstrated a greater Negative central (Nc) ERP response to the deviant actions for the pair that caused the action-effect, which was consistent with their visual anticipations during the learning phase. Findings are discussed in terms of the neural and behavioral processes underlying perception and learning of structured action sequences. Copyright © 2017 Elsevier Ltd. All rights reserved.

  13. Exploring interaction with 3D volumetric displays

    Science.gov (United States)

    Grossman, Tovi; Wigdor, Daniel; Balakrishnan, Ravin

    2005-03-01

    Volumetric displays generate true volumetric 3D images by actually illuminating points in 3D space. As a result, viewing their contents is similar to viewing physical objects in the real world. These displays provide a 360 degree field of view, and do not require the user to wear hardware such as shutter glasses or head-trackers. These properties make them a promising alternative to traditional display systems for viewing imagery in 3D. Because these displays have only recently been made available commercially (e.g., www.actuality-systems.com), their current use tends to be limited to non-interactive output-only display devices. To take full advantage of the unique features of these displays, however, it would be desirable if the 3D data being displayed could be directly interacted with and manipulated. We investigate interaction techniques for volumetric display interfaces, through the development of an interactive 3D geometric model building application. While this application area itself presents many interesting challenges, our focus is on the interaction techniques that are likely generalizable to interactive applications for other domains. We explore a very direct style of interaction where the user interacts with the virtual data using direct finger manipulations on and around the enclosure surrounding the displayed 3D volumetric image.

  14. Volumetric, dashboard-mounted augmented display

    Science.gov (United States)

    Kessler, David; Grabowski, Christopher

    2017-11-01

    The optical design of a compact volumetric display for drivers is presented. The system displays a true volume image with realistic physical depth cues, such as focal accommodation, parallax and convergence. A large eyebox is achieved with a pupil expander. The windshield is used as the augmented reality combiner. A freeform windshield corrector is placed at the dashboard.

  15. Relationship between somatosensory event-related potential N140 aberrations and hemispatial agnosia in patients with stroke: a preliminary study.

    Science.gov (United States)

    Ueno, Tomoyuki; Hada, Yasushi; Shimizu, Yukiyo; Yamada, Thoru

    2018-06-01

    The somatosensory event-related potential N140 is thought to be related to selective attention. This study aimed to compare the somatosensory event-related potential N140 in healthy subjects to that in patients with stroke to determine whether N140 and attentiveness are associated in patients with stroke with or without hemispatial agnosia. Normal somatosensory event-related potential N140 values were determined using data from ten healthy subjects. Fifteen patients with stroke were divided into two groups based on the presence of hemispatial neglect. Somatosensory event-related potential N140 components were compared between the two groups. Stimulation of the affected limb in the hemispatial agnosia group resulted in significantly longer N140 latency at the contralateral vs. the ipsilateral electrode. This was the inverse of the relationship observed in normal subjects, with stimulation of the intact side in patients with hemispatial agnosia, and with stimulation of both the intact and affected sides in patients without agnosia. In the hemispatial agnosia group, the peak latency of N140 following stimulation of the affected side was significantly longer than it was following stimulation of the intact side and when compared to that in patients without agnosia. In addition, abnormal N140 peak latencies were observed at the Cz and ipsilateral electrodes in patients with hemispatial agnosia following stimulation of the intact side. These findings suggest that somatosensory event-related potential N140 is independently generated in each hemisphere and may reflect cognitive attention.

  16. Examining Event-Related Potential (ERP) correlates of decision bias in recognition memory judgments.

    Science.gov (United States)

    Hill, Holger; Windmann, Sabine

    2014-01-01

    Memory judgments can be based on accurate memory information or on decision bias (the tendency to report that an event is part of episodic memory when one is in fact unsure). Event related potentials (ERP) correlates are important research tools for elucidating the dynamics underlying memory judgments but so far have been established only for investigations of accurate old/new discrimination. To identify the ERP correlates of bias, and observe how these interact with ERP correlates of memory, we conducted three experiments that manipulated decision bias within participants via instructions during recognition memory tests while their ERPs were recorded. In Experiment 1, the bias manipulation was performed between blocks of trials (automatized bias) and compared to trial-by-trial shifts of bias in accord with an external cue (flexibly controlled bias). In Experiment 2, the bias manipulation was performed at two different levels of accurate old/new discrimination as the memory strength of old (studied) items was varied. In Experiment 3, the bias manipulation was added to another, bottom-up driven manipulation of bias induced via familiarity. In the first two Experiments, and in the low familiarity condition of Experiment 3, we found evidence of an early frontocentral ERP component at 320 ms poststimulus (the FN320) that was sensitive to the manipulation of bias via instruction, with more negative amplitudes indexing more liberal bias. By contrast, later during the trial (500-700 ms poststimulus), bias effects interacted with old/new effects across all three experiments. Results suggest that the decision criterion is typically activated early during recognition memory trials, and is integrated with retrieved memory signals and task-specific processing demands later during the trial. More generally, the findings demonstrate how ERPs can help to specify the dynamics of recognition memory processes under top-down and bottom-up controlled retrieval conditions.

  17. Sex differences in event-related potentials and attentional biases to emotional facial stimuli.

    Science.gov (United States)

    Pfabigan, Daniela M; Lamplmayr-Kragl, Elisabeth; Pintzinger, Nina M; Sailer, Uta; Tran, Ulrich S

    2014-01-01

    Attentional processes play an important role in the processing of emotional information. Previous research reported attentional biases during stimulus processing in anxiety and depression. However, sex differences in the processing of emotional stimuli and higher prevalence rates of anxiety disorders among women, compared to men, suggest that attentional biases may also differ between the two sexes. The present study used a modified version of the dot probe task with happy, angry, and neutral facial stimuli to investigate the time course of attentional biases in healthy volunteers. Moreover, associations of attentional biases with alexithymia were examined on the behavioral and physiological level. Event-related potentials were measured while 21 participants (11 women) performed the task, utilizing also for the first time a difference wave approach in the analysis to highlight emotion-specific aspects. Women showed overall enhanced probe P1 amplitudes compared to men, in particular after rewarding facial stimuli. Using the difference wave approach, probe P1 amplitudes appeared specifically enhanced with regard to congruently presented happy facial stimuli among women, compared to men. Both methods yielded enhanced probe P1 amplitudes after presentation of the emotional stimulus in the left compared to the right visual hemifield. Probe P1 amplitudes correlated negatively with self-reported alexithymia, most of these correlations were only observable in women. Our results suggest that women orient their attention to a greater extent to facial stimuli than men and corroborate that alexithymia is a correlate of reduced emotional reactivity on a neuronal level. We recommend using a difference wave approach when addressing attentional processes of orientation and disengagement also in future studies.

  18. Recognition Memory in Amnestic-Mild Cognitive Impairment: Insights from Event-Related Potentials

    Directory of Open Access Journals (Sweden)

    David A Wolk

    2013-12-01

    Full Text Available Episodic memory loss is the hallmark cognitive dysfunction associated with Alzheimer’s Disease (AD. Amnestic Mild Cognitive Impairment (a-MCI frequently represents a transitional stage between normal aging and early AD. A better understanding of the qualitative features of memory loss in a-MCI may have important implications for predicting those most likely to harbor AD-related pathology and for disease monitoring. Dual process models of memory argue that recognition memory is subserved by the dissociable processes of recollection and familiarity. Work studying recognition memory in a-MCI from this perspective has been controversial, particularly with regard to the integrity of familiarity. Event-related potentials (ERPs offer an alternative means for assessing these functions without the associated assumptions of behavioral estimation methods. ERPs were recorded while a-MCI patients and cognitively normal (CN age-matched adults performed a recognition memory task. When retrieval success was measured (hits versus correct rejections in which performance was matched by group, a-MCI patients displayed similar neural correlates to that of the CN group, including modulation of the FN400 and the late parietal complex (LPC which are thought to index familiarity and recollection, respectively. Alternatively, when the integrity of these components were measured based on retrieval attempts (studied versus unstudied items, a-MCI patients displayed a reduced FN400 and LPC. Furthermore, modulation of the FN400 correlated with a behavioral estimate of familiarity and the LPC with a behavioral estimates of recollection obtained in a separate experiment in the same individuals, consistent with the proposed mappings of these indices. These results support a global decline of recognition memory in a-MCI, which suggests that the memory loss of prodromal AD may be qualitatively distinct from normal aging.

  19. An Event-Related Potential Examination of Contour Integration Deficits in Schizophrenia

    Directory of Open Access Journals (Sweden)

    Pamela D Butler

    2013-03-01

    Full Text Available Perceptual organization, which refers to the ability to integrate fragments of stimuli to form a representation of a whole edge, part, or object, is impaired in schizophrenia. A contour integration paradigm, involving detection of a set of Gabor patches forming an oval contour pointing to the right or left embedded in a field of randomly oriented Gabors, has been developed for use in clinical trials of schizophrenia. The purpose of the present study was to assess contributions of early and later stages of processing to deficits in contour integration, as well as to develop an event-related potential (ERP analog of this task. Twenty-one patients with schizophrenia and 28 controls participated. The Gabor elements forming the contours were given a low or high degree of orientational jitter, making it either easy or difficult to identify the direction in which the contour was pointing. ERP results showed greater negative peaks at ~165 (N1 component and ~270 ms for the low-jitter versus the high-jitter contours, with a much greater difference between jitter conditions at 270 ms. This later ERP component was previously termed Ncl for closure negativity. Source localization identified the Ncl in the lateral occipital object recognition area. Patients showed a significant decrease in the Ncl, but not N1, compared to controls, and this was associated with impaired behavioral ability to identify contours. In addition, an earlier negative peak was found at ~120 ms (termed N120 that differentiated jitter conditions, had a dorsal stream source, and differed between patients and controls. Patients also showed a deficit in the dorsal stream sensory P1 component. These results are in accord with impairments in distributed circuitry contributing to perceptual organization deficits and provide an ERP analog to the behavioral contour integration task.

  20. Anticipation of electric shocks modulates low beta power and event-related fields during memory encoding.

    Science.gov (United States)

    Bauch, Eva M; Bunzeck, Nico

    2015-09-01

    In humans, the temporal and oscillatory dynamics of pain anticipation and its effects on long-term memory are largely unknown. Here, we investigated this open question by using a previously established behavioral paradigm in combination with magnetoencephalography (MEG). Healthy human subjects encoded a series of scene images, which was combined with cues predicting an aversive electric shock with different probabilities (0.2, 0.5 or 0.8). After encoding, memory for the studied images was tested using a remember/know recognition task. Behaviorally, pain anticipation did not modulate recollection-based recognition memory per se, but interacted with the perceived unpleasantness of the electric shock [visual analogue scale rating from 1 (not unpleasant) to 10 (highly unpleasant)]. More precisely, the relationship between pain anticipation and recollection followed an inverted u-shaped function the more unpleasant the shocks were rated by a subject. At the physiological level, this quadratic effect was mimicked in the event-related magnetic fields associated with successful memory formation ('DM-effect') ∼450ms after image onset at left frontal sensors. Importantly, across all subjects, shock anticipation modulated oscillatory power in the low beta frequency range (13-20Hz) in a linear fashion at left temporal sensors. Taken together, our findings indicate that beta oscillations provide a generic mechanism underlying pain anticipation; the effect on subsequent long-term memory, on the other hand, is much more variable and depends on the level of individual pain perception. As such, our findings give new and important insights into how aversive motivational states can drive memory formation. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Event-related potential correlates of paranormal ideation and unusual experiences.

    Science.gov (United States)

    Sumich, Alex; Kumari, Veena; Gordon, Evian; Tunstall, Nigel; Brammer, Michael

    2008-01-01

    Separate dimensions of schizotypy have been differentially associated with electrophysiological measures of brain function, and further shown to be modified by sex/gender. We investigated event-related potential (ERP) correlates of two subdimensions of positive schizotypy, paranormal ideation (PI) and unusual experiences (UEs). Seventy-two individuals with no psychiatric diagnosis (men=36) completed self-report measures of UE and PI and performed an auditory oddball task. Average scores for N100, N200 and P300 amplitudes were calculated for left and right anterior, central and posterior electrode sites. Multiple linear regression was used to examine the relationships between the measures of schizotypy and ERPs across the entire sample, as well as separately according to sex. PI was inversely associated with P300 amplitude at left-central sites across the entire sample, and at right-anterior electrodes in women only. Right-anterior P300 and right-posterior N100 amplitudes were negatively associated with UE in women only. Across the entire sample, UE was negatively associated with left-central N100 amplitude, and positively associated with left-anterior N200 amplitude. These results provide support from electrophysiological measures for the fractionation of the positive dimension of schizotypy into subdimensions of PI and UE, and lend indirect support to dimensional or quasidimensional conceptions of psychosis. More specifically, they suggest that PI may be associated with alteration in contextual updating processes, and that UE may reflect altered sensory/early-attention (N100) mechanisms. The sex differences observed are consistent with those previously observed in individuals with schizophrenia.

  2. Hemispheric Lateralization of Event-Related Brain Potentials in Different Processing Phases during Unimanual Finger Movements

    Directory of Open Access Journals (Sweden)

    Yi-Wen Li

    2008-04-01

    Full Text Available Previous functional MRI and brain electrophysiology studies have studied the left-right differences during the tapping tasks and found that the activation of left hemisphere was more significant than that of right hemisphere. In this study, we wanted to delineate this lateralization phenomenon not only in the execution phase but also in other processing phases, such as early visual, pre-executive and post-executive phases. We have designed a finger-tapping task to delineate the left-right differences of event related potentials (ERPs to right finger movement in sixteen right handed college students. The mean amplitudes of ERPs were analyzed to examine the left-right dominance of cortical activity in the phase of early visual process (75-120ms, pre-execution (175-260ms, execution (310-420ms and post-execution (420-620ms. In the execution phase, ERPs at the left electrodes were significantly more pronounced than those at the right electrodes (F3 > F4, C3 > C4, P3 > P4, O1 > O2 under the situation without comparing the central electrodes (Fz, Cz, Pz, and Oz. No difference was found between left and right electrodes in other three phases except the C3 electrode still showed more dominant than C4 in the pre- and post-execution phase. In conclusion, the phenomenon of brain lateralization occur major in the execution phase. The central area also showed the lateralization in the pre- and post-execution to demonstrate its unique lateralized contributions to unilateral simple finger movements.

  3. How Social Ties Influence Consumer: Evidence from Event-Related Potentials.

    Directory of Open Access Journals (Sweden)

    Jing Luan

    Full Text Available A considerable amount of marketing research has reported that consumers are more saliently influenced by friends (strong social ties than by acquaintances and strangers (weak social ties. To shed light on the neural and psychological processes underlying such phenomenon, in this study we designed an amended S1-S2 paradigm (product-[reviewer-review] that is based on realistic consumer purchase experiences. After incoming all given information (product, reviewer, review, participants were required to state their purchase intentions. The neurocognitive and emotional processes related to friend and stranger stimuli were delineated to suggest how social ties influence consumers during their shopping processes. Larger P2 (fronto-central scalp areas and P3 (central and posterior-parietal scalp areas components under stranger condition were elicited successfully. These findings demonstrate that the cognitive and emotional processing of friend and stranger stimuli occurs at stages of neural activity, and can be indicated by the P2 and P3 components. Electrophysiological data also support the hypothesis that different neural and emotional processing magnitude and strength underlie friend and stranger effect in the context of consumer purchase. During this process, the perception of stimuli evoked P2, subsequently emotional processing and attention modulation were activated and indicated by P2 and P3. The friend dominated phenomenon can be interpreted as the result of distinctive neurocognitive and emotional processing magnitude, which suggests that psychological and emotional factors can guide consumer decision making. This study consolidates that event related potential (ERP methodology is likely to be a more sensitive method for investigating consumer behaviors. From the perspectives of management and marketing, our findings show that the P2 and P3 components can be employed as an indicator to probe the influential factors of consumer purchase

  4. Deficient multisensory integration in schizophrenia: an event-related potential study.

    Science.gov (United States)

    Stekelenburg, Jeroen J; Maes, Jan Pieter; Van Gool, Arthur R; Sitskoorn, Margriet; Vroomen, Jean

    2013-07-01

    In many natural audiovisual events (e.g., the sight of a face articulating the syllable /ba/), the visual signal precedes the sound and thus allows observers to predict the onset and the content of the sound. In healthy adults, the N1 component of the event-related brain potential (ERP), reflecting neural activity associated with basic sound processing, is suppressed if a sound is accompanied by a video that reliably predicts sound onset. If the sound does not match the content of the video (e.g., hearing /ba/ while lipreading /fu/), the later occurring P2 component is affected. Here, we examined whether these visual information sources affect auditory processing in patients with schizophrenia. The electroencephalography (EEG) was recorded in 18 patients with schizophrenia and compared with that of 18 healthy volunteers. As stimuli we used video recordings of natural actions in which visual information preceded and predicted the onset of the sound that was either congruent or incongruent with the video. For the healthy control group, visual information reduced the auditory-evoked N1 if compared to a sound-only condition, and stimulus-congruency affected the P2. This reduction in N1 was absent in patients with schizophrenia, and the congruency effect on the P2 was diminished. Distributed source estimations revealed deficits in the network subserving audiovisual integration in patients with schizophrenia. The results show a deficit in multisensory processing in patients with schizophrenia and suggest that multisensory integration dysfunction may be an important and, to date, under-researched aspect of schizophrenia. Copyright © 2013. Published by Elsevier B.V.

  5. Automatic temporal expectancy: a high-density event-related potential study.

    Directory of Open Access Journals (Sweden)

    Giovanni Mento

    Full Text Available How we compute time is not fully understood. Questions include whether an automatic brain mechanism is engaged in temporally regular environmental structure in order to anticipate events, and whether this can be dissociated from task-related processes, including response preparation, selection and execution. To investigate these issues, a passive temporal oddball task requiring neither time-based motor response nor explicit decision was specifically designed and delivered to participants during high-density, event-related potentials recording. Participants were presented with pairs of audiovisual stimuli (S1 and S2 interspersed with an Inter-Stimulus Interval (ISI that was manipulated according to an oddball probabilistic distribution. In the standard condition (70% of trials, the ISI lasted 1,500 ms, while in the two alternative, deviant conditions (15% each, it lasted 2,500 and 3,000 ms. The passive over-exposition to the standard ISI drove participants to automatically and progressively create an implicit temporal expectation of S2 onset, reflected by the time course of the Contingent Negative Variation response, which always peaked in correspondence to the point of S2 maximum expectation and afterwards inverted in polarity towards the baseline. Brain source analysis of S1- and ISI-related ERP activity revealed activation of sensorial cortical areas and the supplementary motor area (SMA, respectively. In particular, since the SMA time course synchronised with standard ISI, we suggest that this area is the major cortical generator of the temporal CNV reflecting an automatic, action-independent mechanism underlying temporal expectancy.

  6. Event-related potentials elicited by pre-attentive emotional changes in temporal context.

    Directory of Open Access Journals (Sweden)

    Tomomi Fujimura

    Full Text Available The ability to detect emotional change in the environment is essential for adaptive behavior. The current study investigated whether event-related potentials (ERPs can reflect emotional change in a visual sequence. To assess pre-attentive processing, we examined visual mismatch negativity (vMMN: the negative potentials elicited by a deviant (infrequent stimulus embedded in a sequence of standard (frequent stimuli. Participants in two experiments pre-attentively viewed visual sequences of Japanese kanji with different emotional connotations while ERPs were recorded. The visual sequence in Experiment 1 consisted of neutral standards and two types of emotional deviants with a strong and weak intensity. Although the results indicated that strongly emotional deviants elicited more occipital negativity than neutral standards, it was unclear whether these negativities were derived from emotional deviation in the sequence or from the emotional significance of the deviants themselves. In Experiment 2, the two identical emotional deviants were presented against different emotional standards. One type of deviants was emotionally incongruent with the standard and the other type of deviants was emotionally congruent with the standard. The results indicated that occipital negativities elicited by deviants resulted from perceptual changes in a visual sequence at a latency of 100-200 ms and from emotional changes at latencies of 200-260 ms. Contrary to the results of the ERP experiment, reaction times to deviants showed no effect of emotional context; negative stimuli were consistently detected more rapidly than were positive stimuli. Taken together, the results suggest that brain signals can reflect emotional change in a temporal context.

  7. Distinct modulation of event-related potentials during motor preparation in patients with motor conversion disorder.

    Directory of Open Access Journals (Sweden)

    Rebekah L Blakemore

    Full Text Available OBJECTIVE: Conversion paresis patients and healthy people feigning weakness both exhibit weak voluntary movement without detectable neuropathology. Uniquely, conversion patients lack a sense of conscious awareness of the origin of their impairment. We investigated whether conversion paresis patients show distinct electroencephalographic (EEG markers associated with their unconscious movement deficits. METHODS: Six unilateral upper limb conversion paresis patients, 12 feigning participants asked to mimic weakness and 12 control participants performed a precued reaction time task, requiring movements of either hand, depending on precue information. Performance measures (force, reaction and movement time, and event-related EEG potentials (ERP were compared, between groups and across hands or hemisphere, using linear mixed models. RESULTS: Feigners generated the same inter-hand difference in reaction and movement time as expressed by patients, even though no specific targets were set nor feedback given on these measures. We found novel ERP signatures specific to patients. When the symptomatic hand was precued, the P3 ERP component accompanying the precue was dramatically larger in patients than in feigning participants. Additionally, in patients the earlier N1 ERP component was diminished when the precue signalled either the symptomatic or asymptomatic hand. CONCLUSIONS: These results are consistent with previous suggestions that lack of awareness of the origin of their symptoms in conversion disorder patients may result from suppression of brain activity normally related to self-agency. In patients the diminished N1 to all precues is consistent with a generalised reduction in cognitive processing of movement-related precues. The P3 enhancement in patients is unlikely to simply reflect changes required for generation of impaired movements, because it was not seen in feigners showing the same behavioural deficits. Rather, this P3 enhancement in

  8. Statistical analysis of events related to emergency diesel generators failures in the nuclear industry

    Energy Technology Data Exchange (ETDEWEB)

    Kančev, Duško, E-mail: dusko.kancev@ec.europa.eu [European Commission, DG-JRC, Institute for Energy and Transport, P.O. Box 2, NL-1755 ZG Petten (Netherlands); Duchac, Alexander; Zerger, Benoit [European Commission, DG-JRC, Institute for Energy and Transport, P.O. Box 2, NL-1755 ZG Petten (Netherlands); Maqua, Michael [Gesellschaft für Anlagen-und-Reaktorsicherheit (GRS) mbH, Schwetnergasse 1, 50667 Köln (Germany); Wattrelos, Didier [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), BP 17 - 92262 Fontenay-aux-Roses Cedex (France)

    2014-07-01

    Highlights: • Analysis of operating experience related to emergency diesel generators events at NPPs. • Four abundant operating experience databases screened. • Delineating important insights and conclusions based on the operating experience. - Abstract: This paper is aimed at studying the operating experience related to emergency diesel generators (EDGs) events at nuclear power plants collected from the past 20 years. Events related to EDGs failures and/or unavailability as well as all the supporting equipment are in the focus of the analysis. The selected operating experience was analyzed in detail in order to identify the type of failures, attributes that contributed to the failure, failure modes potential or real, discuss risk relevance, summarize important lessons learned, and provide recommendations. The study in this particular paper is tightly related to the performing of statistical analysis of the operating experience. For the purpose of this study EDG failure is defined as EDG failure to function on demand (i.e. fail to start, fail to run) or during testing, or an unavailability of an EDG, except of unavailability due to regular maintenance. The Gesellschaft für Anlagen und Reaktorsicherheit mbH (GRS) and Institut de Radioprotection et de Sûreté Nucléaire (IRSN) databases as well as the operating experience contained in the IAEA/NEA International Reporting System for Operating Experience and the U.S. Licensee Event Reports were screened. The screening methodology applied for each of the four different databases is presented. Further on, analysis aimed at delineating the causes, root causes, contributing factors and consequences are performed. A statistical analysis was performed related to the chronology of events, types of failures, the operational circumstances of detection of the failure and the affected components/subsystems. The conclusions and results of the statistical analysis are discussed. The main findings concerning the testing

  9. The neural basis of analogical reasoning: an event-related potential study.

    Science.gov (United States)

    Qiu, Jiang; Li, Hong; Chen, Antao; Zhang, Qinglin

    2008-10-01

    The spatiotemporal analysis of brain activation during the execution of easy analogy (EA) and difficult analogy (DA) tasks was investigated using high-density event-related brain potentials (ERPs). Results showed that reasoning tasks (schema induction) elicited a more negative ERP deflection (N500-1000) than did the baseline task (BS) between 500 and 1000 ms. Dipole source analysis of difference waves (EA-BS and DA-BS) indicated that the negative components were both localized near the left thalamus, possibly associated with the retrieval of alphabetical information. Furthermore, DA elicited a more positive ERP component (P600-1000) than did EA in the same time window. Two generators of P600-1000 were located in the medial prefrontal cortex (BA10) and the left frontal cortex (BA6) which was possibly involved in integrating information in schema abstraction. In the stage of analogy mapping, a greater negativity (N400-600) in the reasoning tasks as compared to BS was found over fronto-central scalp regions. A generator of this effect was located in the left fusiform gyrus and was possibly related to associative memory and activation of schema. Then, a greater negativity in the reasoning tasks, in comparison to BS task, developed between 900-1200 ms (LNC1) and 2000-2500 ms (LNC2). Dipole source analysis (EA-BS) localized the generator of LNC1 in the left prefrontal cortex (BA 10) which was possibly related to mapping the schema to the target problem, and the generator of LNC2 in the left prefrontal cortex (BA 9) which was possibly related to deciding whether a conclusion correctly follows from the schema.

  10. The neuromechanism underlying verbal analogical reasoning of metaphorical relations: an event-related potentials study.

    Science.gov (United States)

    Zhao, Ming; Meng, Huishan; Xu, Zhiyuan; Du, Fenglei; Liu, Tao; Li, Yongxin; Chen, Feiyan

    2011-11-24

    Using event-related potentials (ERPs), this study investigated the neuromechanism underlying verbal analogical reasoning of two different metaphorical relations: attributive metaphor and relational metaphor. The analogical reasoning of attributive metaphor (AM-AR) involves a superficial similarity between analogues, while the analogical reasoning of relational metaphor (RM-AR) requires a structural similarity. Subjects were asked to judge whether one word pair was semantically analogous to another word pair. Results showed that the schema induction stage elicited a greater N400 component at the right anterior scalp for the AM-AR and RM-AR tasks, possibly attributable to semantic processing of metaphorical word pairs. The N400 was then followed by a widely distributed P300 and a late negative component (LNC1) at the left anterior scalp. The P300 was possibly related to the formation of a relational category, while the LNC1 was possibly related to the maintenance of a reasoning cue in working memory. The analogy mapping stage elicited broadly distributed N400 and LNC2, which might indicate the presence of semantic retrieval and analogical transfer. In the answer production stage, all conditions elicited the P2 component due to early stimulus encoding. The largest P2 amplitude was in the RM-AR task. The RM-AR elicited a larger LPC than did the AM-AR, even though the baseline correction was taken as a control for the differential P2 effect. The LPC effect might suggest that relational metaphors involved more integration processing than attributive metaphors. Copyright © 2011 Elsevier B.V. All rights reserved.

  11. An Event Related Field Study of Rapid Grammatical Plasticity in Adult Second-Language Learners

    Science.gov (United States)

    Bastarrika, Ainhoa; Davidson, Douglas J.

    2017-01-01

    The present study used magnetoencephalography (MEG) to investigate how Spanish adult learners of Basque respond to morphosyntactic violations after a short period of training on a small fragment of Basque grammar. Participants (n = 17) were exposed to violation and control phrases in three phases (pretest, training, generalization-test). In each phase participants listened to short Basque phrases and they judged whether they were correct or incorrect. During the pre-test and generalization-test, participants did not receive any feedback. During the training blocks feedback was provided after each response. We also ran two Spanish control blocks before and after training. We analyzed the event-related magnetic- field (ERF) recorded in response to a critical word during all three phases. In the pretest, classification was below chance and we found no electrophysiological differences between violation and control stimuli. Then participants were explicitly taught a Basque grammar rule. From the first training block participants were able to correctly classify control and violation stimuli and an evoked violation response was present. Although the timing of the electrophysiological responses matched participants' L1 effect, the effect size was smaller for L2 and the topographical distribution differed from the L1. While the L1 effect was bilaterally distributed on the auditory sensors, the L2 effect was present at right frontal sensors. During training blocks two and three, the violation-control effect size increased and the topography evolved to a more L1-like pattern. Moreover, this pattern was maintained in the generalization test. We conclude that rapid changes in neuronal responses can be observed in adult learners of a simple morphosyntactic rule, and that native-like responses can be achieved at least in small fragments of second language. PMID:28174530

  12. Competitive Semantic Memory Retrieval: Temporal Dynamics Revealed by Event-Related Potentials.

    Directory of Open Access Journals (Sweden)

    Robin Hellerstedt

    Full Text Available Memories compete for retrieval when they are related to a common retrieval cue. Previous research has shown that retrieval of a target memory may lead to subsequent retrieval-induced forgetting (RIF of currently irrelevant competing memories. In the present study, we investigated the time course of competitive semantic retrieval and examined the neurocognitive mechanisms underlying RIF. We contrasted two theoretical accounts of RIF by examining a critical aspect of this memory phenomenon, namely the extent to which it depends on successful retrieval of the target memory. Participants first studied category-exemplar word-pairs (e.g. Fruit-Apple. Next, we recorded electrophysiological measures of brain activity while the participants performed a competitive semantic cued-recall task. In this task, the participants were provided with the studied categories but they were instructed to retrieve other unstudied exemplars (e.g. Fruit-Ma__?. We investigated the event-related potential (ERP correlates of retrieval success by comparing ERPs from successful and failed retrieval trials. To isolate the ERP correlates of continuous retrieval attempts from the ERP correlates of retrieval success, we included an impossible retrieval condition, with incompletable word-stem cues (Drinks-Wy__ and compared it with a non-retrieval presentation baseline condition (Occupation-Dentist. The participants' memory for all the studied exemplars was tested in the final phase of the experiment. Taken together, the behavioural results suggest that RIF is independent of target retrieval. Beyond investigating the mechanisms underlying RIF, the present study also elucidates the temporal dynamics of semantic cued-recall by isolating the ERP correlates of retrieval attempt and retrieval success. The ERP results revealed that retrieval attempt is reflected in a late posterior negativity, possibly indicating construction of candidates for completing the word-stem cue and retrieval

  13. Competitive Semantic Memory Retrieval: Temporal Dynamics Revealed by Event-Related Potentials

    Science.gov (United States)

    Hellerstedt, Robin; Johansson, Mikael

    2016-01-01

    Memories compete for retrieval when they are related to a common retrieval cue. Previous research has shown that retrieval of a target memory may lead to subsequent retrieval-induced forgetting (RIF) of currently irrelevant competing memories. In the present study, we investigated the time course of competitive semantic retrieval and examined the neurocognitive mechanisms underlying RIF. We contrasted two theoretical accounts of RIF by examining a critical aspect of this memory phenomenon, namely the extent to which it depends on successful retrieval of the target memory. Participants first studied category-exemplar word-pairs (e.g. Fruit—Apple). Next, we recorded electrophysiological measures of brain activity while the participants performed a competitive semantic cued-recall task. In this task, the participants were provided with the studied categories but they were instructed to retrieve other unstudied exemplars (e.g. Fruit—Ma__?). We investigated the event-related potential (ERP) correlates of retrieval success by comparing ERPs from successful and failed retrieval trials. To isolate the ERP correlates of continuous retrieval attempts from the ERP correlates of retrieval success, we included an impossible retrieval condition, with incompletable word-stem cues (Drinks—Wy__) and compared it with a non-retrieval presentation baseline condition (Occupation—Dentist). The participants’ memory for all the studied exemplars was tested in the final phase of the experiment. Taken together, the behavioural results suggest that RIF is independent of target retrieval. Beyond investigating the mechanisms underlying RIF, the present study also elucidates the temporal dynamics of semantic cued-recall by isolating the ERP correlates of retrieval attempt and retrieval success. The ERP results revealed that retrieval attempt is reflected in a late posterior negativity, possibly indicating construction of candidates for completing the word-stem cue and retrieval

  14. Effects of Age and Working Memory Load on Syntactic Processing: An Event-Related Potential Study

    Directory of Open Access Journals (Sweden)

    Graciela C. Alatorre-Cruz

    2018-05-01

    Full Text Available Cognitive changes in aging include working memory (WM decline, which may hamper language comprehension. An increase in WM demands in older adults would probably provoke a poorer sentence processing performance in this age group. A way to increase the WM load is to separate two lexical units in an agreement relation (i.e., adjective and noun, in a given sentence. To test this hypothesis, event-related potentials (ERPs were collected from Spanish speakers (30 older adults, mean age = 66.06 years old; and 30 young adults, mean age = 25.7 years old who read sentences to detect grammatical errors. The sentences varied with regard to (1 the gender agreement of the noun and adjective, where the gender of the adjective either agreed or disagreed with the noun, and (2 the WM load (i.e., the number of words between the noun and adjective in the sentence. No significant behavioral differences between groups were observed in the accuracy of the response, but older adults showed longer reaction times regardless of WM load condition. Compared with young participants, older adults showed a different pattern of ERP components characterized by smaller amplitudes of LAN, P600a, and P600b effects when the WM load was increased. A smaller LAN effect probably reflects greater difficulties in processing the morpho-syntactic features of the sentence, while smaller P600a and P600b effects could be related to difficulties in recovering and mapping all sentence constituents. We concluded that the ERP pattern in older adults showed subtle problems in syntactic processing when the WM load was increased, which was not sufficient to affect response accuracy but was only observed to result in a longer reaction time.

  15. Attention bias in earthquake-exposed survivors: an event-related potential study.

    Science.gov (United States)

    Zhang, Yan; Kong, Fanchang; Han, Li; Najam Ul Hasan, Abbasi; Chen, Hong

    2014-12-01

    The Chinese Wenchuan earthquake, which happened on the 28th of May in 2008, may leave deep invisible scars in individuals. China has a large number of children and adolescents, who tend to be most vulnerable because they are in an early stage of human development and possible post-traumatic psychological distress may have a life-long consequence. Trauma survivors without post-traumatic stress disorder (PTSD) have received little attention in previous studies, especially in event-related potential (ERP) studies. We compared the attention bias to threat stimuli between the earthquake-exposed group and the control group in a masked version of the dot probe task. The target probe presented at the same space location consistent with earthquake-related words was the congruent trial, while in the space location of neutral words was the incongruent trial. Thirteen earthquake-exposed middle school students without PTSD and 13 matched controls were included in this investigation. The earthquake-exposed group showed significantly faster RTs to congruent trials than to incongruent trials. The earthquake-exposed group produced significantly shorter C1 and P1 latencies and larger C1, P1 and P2 amplitudes than the control group. In particular, enhanced P1 amplitude to threat stimuli was observed in the earthquake-exposed group. These findings are in agreement with the prediction that earthquake-exposed survivors have an attention bias to threat stimuli. The traumatic event had a much greater effect on earthquake-exposed survivors even if they showed no PTSD symptoms than individuals in the controls. These results will provide neurobiological evidences for effective intervention and prevention to post-traumatic mental problems. Copyright © 2014 Elsevier B.V. All rights reserved.

  16. Examining Event-Related Potential (ERP) Correlates of Decision Bias in Recognition Memory Judgments

    Science.gov (United States)

    Hill, Holger; Windmann, Sabine

    2014-01-01

    Memory judgments can be based on accurate memory information or on decision bias (the tendency to report that an event is part of episodic memory when one is in fact unsure). Event related potentials (ERP) correlates are important research tools for elucidating the dynamics underlying memory judgments but so far have been established only for investigations of accurate old/new discrimination. To identify the ERP correlates of bias, and observe how these interact with ERP correlates of memory, we conducted three experiments that manipulated decision bias within participants via instructions during recognition memory tests while their ERPs were recorded. In Experiment 1, the bias manipulation was performed between blocks of trials (automatized bias) and compared to trial-by-trial shifts of bias in accord with an external cue (flexibly controlled bias). In Experiment 2, the bias manipulation was performed at two different levels of accurate old/new discrimination as the memory strength of old (studied) items was varied. In Experiment 3, the bias manipulation was added to another, bottom-up driven manipulation of bias induced via familiarity. In the first two Experiments, and in the low familiarity condition of Experiment 3, we found evidence of an early frontocentral ERP component at 320 ms poststimulus (the FN320) that was sensitive to the manipulation of bias via instruction, with more negative amplitudes indexing more liberal bias. By contrast, later during the trial (500–700 ms poststimulus), bias effects interacted with old/new effects across all three experiments. Results suggest that the decision criterion is typically activated early during recognition memory trials, and is integrated with retrieved memory signals and task-specific processing demands later during the trial. More generally, the findings demonstrate how ERPs can help to specify the dynamics of recognition memory processes under top-down and bottom-up controlled retrieval conditions. PMID

  17. Event-related rTMS at encoding affects differently deep and shallow memory traces.

    Science.gov (United States)

    Innocenti, Iglis; Giovannelli, Fabio; Cincotta, Massimo; Feurra, Matteo; Polizzotto, Nicola R; Bianco, Giovanni; Cappa, Stefano F; Rossi, Simone

    2010-10-15

    The "level of processing" effect is a classical finding of the experimental psychology of memory. Actually, the depth of information processing at encoding predicts the accuracy of the subsequent episodic memory performance. When the incoming stimuli are analyzed in terms of their meaning (semantic, or deep, encoding), the memory performance is superior with respect to the case in which the same stimuli are analyzed in terms of their perceptual features (shallow encoding). As suggested by previous neuroimaging studies and by some preliminary findings with transcranial magnetic stimulation (TMS), the left prefrontal cortex may play a role in semantic processing requiring the allocation of working memory resources. However, it still remains unclear whether deep and shallow encoding share or not the same cortical networks, as well as how these networks contribute to the "level of processing" effect. To investigate the brain areas casually involved in this phenomenon, we applied event-related repetitive TMS (rTMS) during deep (semantic) and shallow (perceptual) encoding of words. Retrieval was subsequently tested without rTMS interference. RTMS applied to the left dorsolateral prefrontal cortex (DLPFC) abolished the beneficial effect of deep encoding on memory performance, both in terms of accuracy (decrease) and reaction times (increase). Neither accuracy nor reaction times were instead affected by rTMS to the right DLPFC or to an additional control site excluded by the memory process (vertex). The fact that online measures of semantic processing at encoding were unaffected suggests that the detrimental effect on memory performance for semantically encoded items took place in the subsequent consolidation phase. These results highlight the specific causal role of the left DLPFC among the wide left-lateralized cortical network engaged by long-term memory, suggesting that it probably represents a crucial node responsible for the improved memory performance induced by

  18. Effects of low-frequency repetitive transcranial magnetic stimulation on event-related potential P300

    Science.gov (United States)

    Torii, Tetsuya; Sato, Aya; Iwahashi, Masakuni; Iramina, Keiji

    2012-04-01

    The present study analyzed the effects of repetitive transcranial magnetic stimulation (rTMS) on brain activity. P300 latency of event-related potential (ERP) was used to evaluate the effects of low-frequency and short-term rTMS by stimulating the supramarginal gyrus (SMG), which is considered to be the related area of P300 origin. In addition, the prolonged stimulation effects on P300 latency were analyzed after applying rTMS. A figure-eight coil was used to stimulate left-right SMG, and intensity of magnetic stimulation was 80% of motor threshold. A total of 100 magnetic pulses were applied for rTMS. The effects of stimulus frequency at 0.5 or 1 Hz were determined. Following rTMS, an odd-ball task was performed and P300 latency of ERP was measured. The odd-ball task was performed at 5, 10, and 15 min post-rTMS. ERP was measured prior to magnetic stimulation as a control. Electroencephalograph (EEG) was measured at Fz, Cz, and Pz that were indicated by the international 10-20 electrode system. Results demonstrated that different effects on P300 latency occurred between 0.5-1 Hz rTMS. With 1 Hz low-frequency magnetic stimulation to the left SMG, P300 latency decreased. Compared to the control, the latency time difference was approximately 15 ms at Cz. This decrease continued for approximately 10 min post-rTMS. In contrast, 0.5 Hz rTMS resulted in delayed P300 latency. Compared to the control, the latency time difference was approximately 20 ms at Fz, and this delayed effect continued for approximately 15 min post-rTMS. Results demonstrated that P300 latency varied according to rTMS frequency. Furthermore, the duration of the effect was not similar for stimulus frequency of low-frequency rTMS.

  19. Encoding of faces and objects into visual working memory: an event-related brain potential study.

    Science.gov (United States)

    Meinhardt-Injac, Bozana; Persike, Malte; Berti, Stefan

    2013-09-11

    Visual working memory (VWM) is an important prerequisite for cognitive functions, but little is known on whether the general perceptual processing advantage for faces also applies to VWM processes. The aim of the present study was (a) to test whether there is a general advantage for face stimuli in VWM and (b) to unravel whether this advantage is related to early sensory processing stages. To address these questions, we compared encoding of faces and complex nonfacial objects into VWM within a combined behavioral and event-related brain potential (ERP) study. In detail, we tested whether the N170 ERP component - which is associated with face-specific holistic processing - is affected by memory load for faces or whether it might be involved in WM encoding of any complex object. Participants performed a same-different task with either face or watch stimuli and with two different levels of memory load. Behavioral measures show an advantage for faces on the level of VWM, mirrored in higher estimated VWM capacity (i.e. Cowan's K) for faces compared with watches. In the ERP, the N170 amplitude was enhanced for faces compared with watches. However, the N170 was not modulated by working memory load either for faces or for watches. In contrast, the P3b component was affected by memory load irrespective of the stimulus category. Taken together, the results suggest that the VWM advantage for faces is not reflected at the sensory stages of stimulus processing, but rather at later higher-level processes as reflected by the P3b component.

  20. Event-related potentials reflect impaired temporal interval learning following haloperidol administration.

    Science.gov (United States)

    Forster, Sarah E; Zirnheld, Patrick; Shekhar, Anantha; Steinhauer, Stuart R; O'Donnell, Brian F; Hetrick, William P

    2017-09-01

    Signals carried by the mesencephalic dopamine system and conveyed to anterior cingulate cortex are critically implicated in probabilistic reward learning and performance monitoring. A common evaluative mechanism purportedly subserves both functions, giving rise to homologous medial frontal negativities in feedback- and response-locked event-related brain potentials (the feedback-related negativity (FRN) and the error-related negativity (ERN), respectively), reflecting dopamine-dependent prediction error signals to unexpectedly negative events. Consistent with this model, the dopamine receptor antagonist, haloperidol, attenuates the ERN, but effects on FRN have not yet been evaluated. ERN and FRN were recorded during a temporal interval learning task (TILT) following randomized, double-blind administration of haloperidol (3 mg; n = 18), diphenhydramine (an active control for haloperidol; 25 mg; n = 20), or placebo (n = 21) to healthy controls. Centroparietal positivities, the Pe and feedback-locked P300, were also measured and correlations between ERP measures and behavioral indices of learning, overall accuracy, and post-error compensatory behavior were evaluated. We hypothesized that haloperidol would reduce ERN and FRN, but that ERN would uniquely track automatic, error-related performance adjustments, while FRN would be associated with learning and overall accuracy. As predicted, ERN was reduced by haloperidol and in those exhibiting less adaptive post-error performance; however, these effects were limited to ERNs following fast timing errors. In contrast, the FRN was not affected by drug condition, although increased FRN amplitude was associated with improved accuracy. Significant drug effects on centroparietal positivities were also absent. Our results support a functional and neurobiological dissociation between the ERN and FRN.

  1. Development of event related negativity together with an internal model of audio-motor associations

    Directory of Open Access Journals (Sweden)

    Kai eLutz

    2013-09-01

    Full Text Available The brain’s reactions to error are manifested in several event related potentials (ERP components, derived from electroencephalographic (EEG signals. Although these components have been known for decades, their interpretation is still controversial. A current hypothesis (first indicator hypothesis claims that the first indication of an action being erroneous leads to a negative deflection of the EEG signal over frontal midline areas. In some cases this requires sensory feedback in the form of knowledge of results (KR. If KR is given, then the first negative deflection can be found around 250 ms after feedback presentation (feedback related negativity, FRN. When KR is not required, a negative deflection is found already around 100 ms after action onset (ERN. This deflection may be evoked when a mismatch between required and actually executed actions is detected. To detect such a mismatch, however, necessitates knowledge about which action is required. To test this assumption, the current study monitored EEG error components during acquisition of an internal model, i.e., acquisition of the knowledge of which actions are needed to reach certain goals. Actions consisted of finger presses on a piano keyboard and goals were tones of a certain pitch to be generated, thus the internal model represented audio-motor mapping. Results show that with increasing proficiency in mapping goals to appropriate actions, the amplitude of the ERN increased, whereas the amplitude of the FRN remained unchanged. Thus, when knowledge is present about which action is required, this supports generation of an ERN around 100ms, likely by detecting a mismatch between required and performed actions. This is in accordance with the first indicator hypothesis. The present study furthermore lends support to the notion that FRN mainly relies on comparison of sensory targets with sensory feedback.

  2. Cerebral lesions and event-related potential P300 using positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Sakai, Yasujiro; Okamoto, Kazuma; Tanaka, Makoto; Kondoh, Susumu; Hirai, Shunsaku

    1993-01-01

    To determine what lesions are involved in prolonging event-related potential P300 latency, regional cerebral blood flow (rCBF) and metabolism were investigated by positron emission tomography (PET) in a total of 40 patients with neurologic diseases (12 with chronic cerebrovascular disorder, 9 with spino-cerebellar degeneration, 4 with Alzheimer's type dementia, 4 with amyotrophic lateral sclerosis, and 11 with miscellaneous diseases). There was inverse correlation between rCBF and P300 latency in terms of any of the whole, left, and right hemispheres: P300 latency was associated with decreased rCBF. This was more noticeable in the cerebral cortex than white matter and in the right than left hemisphere, although there was no significant difference between them. In none of the regions, however, was there significant correlation between cerebral oxygen consumption and P300 latency. When the right and left frontal, temporal, parietal and occipital cortexes, thalamus, putamen, and caudatum were examined as regions of interest, there was significantly inverse correlation between rCBF and P300 latency in all regions except for the occipital cortex. This was more noticeable on the right than the left side, although no significant difference was observed. Cerebral oxygen consumption in these lesions did not correlate with P300 latency. In the study on bilateral rCBF difference, decreased rCBF confined to the right parietal lobe, bilateral thalamus and bilateral temporal lobes was found to be associated with a significantly prolonged P300 latency. Thus, rCBF in these regions seemed to be particularly responsible for P300 latency. (N.K.)

  3. Using event related potentials to identify a user's behavioural intention aroused by product form design.

    Science.gov (United States)

    Ding, Yi; Guo, Fu; Zhang, Xuefeng; Qu, Qingxing; Liu, Weilin

    2016-07-01

    The capacity of product form to arouse user's behavioural intention plays a decisive role in further user experience, even in purchase decision, while traditional methods rarely give a fully understanding of user experience evoked by product form, especially the feeling of anticipated use of product. Behavioural intention aroused by product form designs has not yet been investigated electrophysiologically. Hence event related potentials (ERPs) were applied to explore the process of behavioural intention when users browsed different smart phone form designs with brand and price not taken into account for mainly studying the brain activity evoked by variety of product forms. Smart phone pictures with different anticipated user experience were displayed with equiprobability randomly. Participants were asked to click the left mouse button when certain picture gave them a feeling of behavioural intention to interact with. The brain signal of each participant was recorded by Curry 7.0. The results show that pictures with an ability to arouse participants' behavioural intention for further experience can evoke enhanced N300 and LPPs (late positive potentials) in central-parietal, parietal and occipital regions. The scalp topography shows that central-parietal, parietal and occipital regions are more activated. The results indicate that the discrepancy of ERPs can reflect the neural activities of behavioural intention formed or not. Moreover, amplitude of ERPs occurred in corresponding brain areas can be used to measure user experience. The exploring of neural correlated with behavioural intention provide an accurate measurement method of user's perception and help marketers to know which product can arouse users' behavioural intention, maybe taken as an evaluating indicator of product design. Copyright © 2016 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  4. Examining Event-Related Potential (ERP correlates of decision bias in recognition memory judgments.

    Directory of Open Access Journals (Sweden)

    Holger Hill

    Full Text Available Memory judgments can be based on accurate memory information or on decision bias (the tendency to report that an event is part of episodic memory when one is in fact unsure. Event related potentials (ERP correlates are important research tools for elucidating the dynamics underlying memory judgments but so far have been established only for investigations of accurate old/new discrimination. To identify the ERP correlates of bias, and observe how these interact with ERP correlates of memory, we conducted three experiments that manipulated decision bias within participants via instructions during recognition memory tests while their ERPs were recorded. In Experiment 1, the bias manipulation was performed between blocks of trials (automatized bias and compared to trial-by-trial shifts of bias in accord with an external cue (flexibly controlled bias. In Experiment 2, the bias manipulation was performed at two different levels of accurate old/new discrimination as the memory strength of old (studied items was varied. In Experiment 3, the bias manipulation was added to another, bottom-up driven manipulation of bias induced via familiarity. In the first two Experiments, and in the low familiarity condition of Experiment 3, we found evidence of an early frontocentral ERP component at 320 ms poststimulus (the FN320 that was sensitive to the manipulation of bias via instruction, with more negative amplitudes indexing more liberal bias. By contrast, later during the trial (500-700 ms poststimulus, bias effects interacted with old/new effects across all three experiments. Results suggest that the decision criterion is typically activated early during recognition memory trials, and is integrated with retrieved memory signals and task-specific processing demands later during the trial. More generally, the findings demonstrate how ERPs can help to specify the dynamics of recognition memory processes under top-down and bottom-up controlled retrieval conditions.

  5. Attentional Bias in Patients with Decompensated Tinnitus: Prima Facie Evidence from Event-Related Potentials.

    Science.gov (United States)

    Li, Zhicheng; Gu, Ruolei; Zeng, Xiangli; Zhong, Weifang; Qi, Min; Cen, Jintian

    2016-01-01

    Tinnitus refers to the auditory perception of sound in the absence of external sound or electric stimuli. The influence of tinnitus on cognitive processing is at the cutting edge of ongoing tinnitus research. In this study, we adopted an objective indicator of attentional processing, i.e. the mismatch negativity (MMN), to assess the attentional bias in patients with decompensated tinnitus. Three kinds of pure tones, D1 (8,000 Hz), S (8,500 Hz) and D2 (9,000 Hz), were used to induce event-related potentials (ERPs) in the normal ear. Employing the oddball paradigm, the task was divided into two blocks in which D1 and D2 were set as deviation stimuli, respectively. Only D2 induced a significant MMN in the tinnitus group, while neither D1 nor D2 was able to induce MMN in the control group. In addition, the ERPs in the left hemisphere, which were recorded within the time window of 90-150 ms (ERP 90-150 ms), were significantly higher than those in the right hemisphere in the tinnitus group, while no significant difference was observed in the control group. Lastly, the amplitude of ERP 90-150 ms in the tinnitus group was significantly higher than that in the control group. These findings suggest that patients with decompensated tinnitus showed automatic processing of acoustic stimuli, thereby indicating that these patients allocated more cognitive resources to acoustic stimulus processing. We suggest that the difficulty in disengaging or facilitated attention of patients might underlie this phenomenon. The limitations of the current study are discussed. © 2016 S. Karger AG, Basel.

  6. Feature Extraction of Event-Related Potentials Using Wavelets: An Application to Human Performance Monitoring

    Science.gov (United States)

    Trejo, Leonard J.; Shensa, Mark J.; Remington, Roger W. (Technical Monitor)

    1998-01-01

    This report describes the development and evaluation of mathematical models for predicting human performance from discrete wavelet transforms (DWT) of event-related potentials (ERP) elicited by task-relevant stimuli. The DWT was compared to principal components analysis (PCA) for representation of ERPs in linear regression and neural network models developed to predict a composite measure of human signal detection performance. Linear regression models based on coefficients of the decimated DWT predicted signal detection performance with half as many f ree parameters as comparable models based on PCA scores. In addition, the DWT-based models were more resistant to model degradation due to over-fitting than PCA-based models. Feed-forward neural networks were trained using the backpropagation,-, algorithm to predict signal detection performance based on raw ERPs, PCA scores, or high-power coefficients of the DWT. Neural networks based on high-power DWT coefficients trained with fewer iterations, generalized to new data better, and were more resistant to overfitting than networks based on raw ERPs. Networks based on PCA scores did not generalize to new data as well as either the DWT network or the raw ERP network. The results show that wavelet expansions represent the ERP efficiently and extract behaviorally important features for use in linear regression or neural network models of human performance. The efficiency of the DWT is discussed in terms of its decorrelation and energy compaction properties. In addition, the DWT models provided evidence that a pattern of low-frequency activity (1 to 3.5 Hz) occurring at specific times and scalp locations is a reliable correlate of human signal detection performance.

  7. Transdiagnostic Psychiatric Symptoms and Event-Related Potentials following Rewarding and Aversive Outcomes.

    Directory of Open Access Journals (Sweden)

    Jeffrey S Bedwell

    Full Text Available There is a need for a better understanding of transdiagnostic psychiatric symptoms that relate to neurophysiological abnormalities following rewarding and aversive feedback in order to inform development of novel targeted treatments. To address this need, we examined a transdiagnostic sample of 44 adults (mean age: 35.52; 57% female, which consisted of individuals with broadly-defined schizophrenia-spectrum disorders (n = 16, bipolar disorders (n = 10, other mood and anxiety disorders (n = 5, and no history of a psychiatric disorder (n = 13. Participants completed a Pavlovian monetary reward prediction task during 32-channel electroencephalogram recording. We assessed the event-related potentials (ERPs of feedback-related negativity (FRN, feedback-related positivity (FRP, and the late positive potential (LPP, following better and worse than expected outcomes. Examination of symptom relationships using stepwise regressions across the entire sample revealed that an increase in the clinician-rated Negative Symptoms factor score from the Positive and Negative Syndrome Scale, was related to a decreased LPP amplitude during better than expected (i.e., rewarding outcomes. We also found that increased self-reported scores on the Schizotypal Personality Questionnaire (Brief-Revised Disorganized factor related to an increased FRN amplitude during worse than expected (i.e., aversive outcomes. Across the entire sample, the FRP component amplitudes did not show significant relationships to any of the symptoms examined. Analyses of the three diagnostic groups of schizophrenia-spectrum disorders, bipolar disorders, and nonpsychiatric controls did not reveal any statistically significant differences across the ERP amplitudes and conditions. These findings suggest relationships between specific neurophysiological abnormalities following rewarding and aversive outcomes and particular transdiagnostic psychiatric symptoms.

  8. Auditory selective attention in adolescents with major depression: An event-related potential study.

    Science.gov (United States)

    Greimel, E; Trinkl, M; Bartling, J; Bakos, S; Grossheinrich, N; Schulte-Körne, G

    2015-02-01

    Major depression (MD) is associated with deficits in selective attention. Previous studies in adults with MD using event-related potentials (ERPs) reported abnormalities in the neurophysiological correlates of auditory selective attention. However, it is yet unclear whether these findings can be generalized to MD in adolescence. Thus, the aim of the present ERP study was to explore the neural mechanisms of auditory selective attention in adolescents with MD. 24 male and female unmedicated adolescents with MD and 21 control subjects were included in the study. ERPs were collected during an auditory oddball paradigm. Depressive adolescents tended to show a longer N100 latency to target and non-target tones. Moreover, MD subjects showed a prolonged latency of the P200 component to targets. Across groups, longer P200 latency was associated with a decreased tendency of disinhibited behavior as assessed by a behavioral questionnaire. To be able to draw more precise conclusions about differences between the neural bases of selective attention in adolescents vs. adults with MD, future studies should include both age groups and apply the same experimental setting across all subjects. The study provides strong support for abnormalities in the neurophysiolgical bases of selective attention in adolecents with MD at early stages of auditory information processing. Absent group differences in later ERP components reflecting voluntary attentional processes stand in contrast to results reported in adults with MD and may suggest that adolescents with MD possess mechanisms to compensate for abnormalities in the early stages of selective attention. Copyright © 2014 Elsevier B.V. All rights reserved.

  9. Differential beta-band event-related desynchronization during categorical action sequence planning.

    Directory of Open Access Journals (Sweden)

    Hame Park

    Full Text Available A primate study reported the existence of neurons from the dorso-lateral prefrontal cortex which fired prior to executing categorical action sequences. The authors suggested these activities may represent abstract level information. Here, we aimed to find the neurophysiological representation of planning categorical action sequences at the population level in healthy humans. Previous human studies have shown beta-band event-related desynchronization (ERD during action planning in humans. Some of these studies showed different levels of ERD according to different types of action preparation. Especially, the literature suggests that variations in cognitive factors rather than physical factors (force, direction, etc modulate the level of beta-ERD. We hypothesized that the level of beta-band power will differ according to planning of different categorical sequences. We measured magnetoencephalography (MEG from 22 subjects performing 11 four-sequence actions--each consisting of one or two of three simple actions--in 3 categories; 'Paired (ooxx', 'Alternative (oxox' and 'Repetitive (oooo' ('o' and 'x' each denoting one of three simple actions. Time-frequency representations were calculated for each category during the planning period, and the corresponding beta-power time-courses were compared. We found beta-ERD during the planning period for all subjects, mostly in the contralateral fronto-parietal areas shortly after visual cue onset. Power increase (transient rebound followed ERD in 20 out of 22 subjects. Amplitudes differed among categories in 20 subjects for both ERD and transient rebound. In 18 out of 20 subjects 'Repetitive' category showed the largest ERD and rebound. The current result suggests that beta-ERD in the contralateral frontal/motor/parietal areas during planning is differentiated by the category of action sequences.

  10. The modulating effect of personality traits on neural error monitoring: evidence from event-related FMRI.

    Science.gov (United States)

    Sosic-Vasic, Zrinka; Ulrich, Martin; Ruchsow, Martin; Vasic, Nenad; Grön, Georg

    2012-01-01

    The present study investigated the association between traits of the Five Factor Model of Personality (Neuroticism, Extraversion, Openness for Experiences, Agreeableness, and Conscientiousness) and neural correlates of error monitoring obtained from a combined Eriksen-Flanker-Go/NoGo task during event-related functional magnetic resonance imaging in 27 healthy subjects. Individual expressions of personality traits were measured using the NEO-PI-R questionnaire. Conscientiousness correlated positively with error signaling in the left inferior frontal gyrus and adjacent anterior insula (IFG/aI). A second strong positive correlation was observed in the anterior cingulate gyrus (ACC). Neuroticism was negatively correlated with error signaling in the inferior frontal cortex possibly reflecting the negative inter-correlation between both scales observed on the behavioral level. Under present statistical thresholds no significant results were obtained for remaining scales. Aligning the personality trait of Conscientiousness with task accomplishment striving behavior the correlation in the left IFG/aI possibly reflects an inter-individually different involvement whenever task-set related memory representations are violated by the occurrence of errors. The strong correlations in the ACC may indicate that more conscientious subjects were stronger affected by these violations of a given task-set expressed by individually different, negatively valenced signals conveyed by the ACC upon occurrence of an error. Present results illustrate that for predicting individual responses to errors underlying personality traits should be taken into account and also lend external validity to the personality trait approach suggesting that personality constructs do reflect more than mere descriptive taxonomies.

  11. The modulating effect of personality traits on neural error monitoring: evidence from event-related FMRI.

    Directory of Open Access Journals (Sweden)

    Zrinka Sosic-Vasic

    Full Text Available The present study investigated the association between traits of the Five Factor Model of Personality (Neuroticism, Extraversion, Openness for Experiences, Agreeableness, and Conscientiousness and neural correlates of error monitoring obtained from a combined Eriksen-Flanker-Go/NoGo task during event-related functional magnetic resonance imaging in 27 healthy subjects. Individual expressions of personality traits were measured using the NEO-PI-R questionnaire. Conscientiousness correlated positively with error signaling in the left inferior frontal gyrus and adjacent anterior insula (IFG/aI. A second strong positive correlation was observed in the anterior cingulate gyrus (ACC. Neuroticism was negatively correlated with error signaling in the inferior frontal cortex possibly reflecting the negative inter-correlation between both scales observed on the behavioral level. Under present statistical thresholds no significant results were obtained for remaining scales. Aligning the personality trait of Conscientiousness with task accomplishment striving behavior the correlation in the left IFG/aI possibly reflects an inter-individually different involvement whenever task-set related memory representations are violated by the occurrence of errors. The strong correlations in the ACC may indicate that more conscientious subjects were stronger affected by these violations of a given task-set expressed by individually different, negatively valenced signals conveyed by the ACC upon occurrence of an error. Present results illustrate that for predicting individual responses to errors underlying personality traits should be taken into account and also lend external validity to the personality trait approach suggesting that personality constructs do reflect more than mere descriptive taxonomies.

  12. Cerebral lesions and event-related potential P300 using positron emission tomography (PET)

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Yasujiro; Okamoto, Kazuma; Tanaka, Makoto; Kondoh, Susumu; Hirai, Shunsaku (Gunma Univ., Maebashi (Japan). School of Medicine)

    1993-06-01

    To determine what lesions are involved in prolonging event-related potential P300 latency, regional cerebral blood flow (rCBF) and metabolism were investigated by positron emission tomography (PET) in a total of 40 patients with neurologic diseases (12 with chronic cerebrovascular disorder, 9 with spino-cerebellar degeneration, 4 with Alzheimer's type dementia, 4 with amyotrophic lateral sclerosis, and 11 with miscellaneous diseases). There was inverse correlation between rCBF and P300 latency in terms of any of the whole, left, and right hemispheres: P300 latency was associated with decreased rCBF. This was more noticeable in the cerebral cortex than white matter and in the right than left hemisphere, although there was no significant difference between them. In none of the regions, however, was there significant correlation between cerebral oxygen consumption and P300 latency. When the right and left frontal, temporal, parietal and occipital cortexes, thalamus, putamen, and caudatum were examined as regions of interest, there was significantly inverse correlation between rCBF and P300 latency in all regions except for the occipital cortex. This was more noticeable on the right than the left side, although no significant difference was observed. Cerebral oxygen consumption in these lesions did not correlate with P300 latency. In the study on bilateral rCBF difference, decreased rCBF confined to the right parietal lobe, bilateral thalamus and bilateral temporal lobes was found to be associated with a significantly prolonged P300 latency. Thus, rCBF in these regions seemed to be particularly responsible for P300 latency. (N.K.).

  13. How Social Ties Influence Consumer: Evidence from Event-Related Potentials.

    Science.gov (United States)

    Luan, Jing; Yao, Zhong; Bai, Yan

    2017-01-01

    A considerable amount of marketing research has reported that consumers are more saliently influenced by friends (strong social ties) than by acquaintances and strangers (weak social ties). To shed light on the neural and psychological processes underlying such phenomenon, in this study we designed an amended S1-S2 paradigm (product-[reviewer-review]) that is based on realistic consumer purchase experiences. After incoming all given information (product, reviewer, review), participants were required to state their purchase intentions. The neurocognitive and emotional processes related to friend and stranger stimuli were delineated to suggest how social ties influence consumers during their shopping processes. Larger P2 (fronto-central scalp areas) and P3 (central and posterior-parietal scalp areas) components under stranger condition were elicited successfully. These findings demonstrate that the cognitive and emotional processing of friend and stranger stimuli occurs at stages of neural activity, and can be indicated by the P2 and P3 components. Electrophysiological data also support the hypothesis that different neural and emotional processing magnitude and strength underlie friend and stranger effect in the context of consumer purchase. During this process, the perception of stimuli evoked P2, subsequently emotional processing and attention modulation were activated and indicated by P2 and P3. The friend dominated phenomenon can be interpreted as the result of distinctive neurocognitive and emotional processing magnitude, which suggests that psychological and emotional factors can guide consumer decision making. This study consolidates that event related potential (ERP) methodology is likely to be a more sensitive method for investigating consumer behaviors. From the perspectives of management and marketing, our findings show that the P2 and P3 components can be employed as an indicator to probe the influential factors of consumer purchase intentions.

  14. Effects of Sound Frequency on Audiovisual Integration: An Event-Related Potential Study.

    Science.gov (United States)

    Yang, Weiping; Yang, Jingjing; Gao, Yulin; Tang, Xiaoyu; Ren, Yanna; Takahashi, Satoshi; Wu, Jinglong

    2015-01-01

    A combination of signals across modalities can facilitate sensory perception. The audiovisual facilitative effect strongly depends on the features of the stimulus. Here, we investigated how sound frequency, which is one of basic features of an auditory signal, modulates audiovisual integration. In this study, the task of the participant was to respond to a visual target stimulus by pressing a key while ignoring auditory stimuli, comprising of tones of different frequencies (0.5, 1, 2.5 and 5 kHz). A significant facilitation of reaction times was obtained following audiovisual stimulation, irrespective of whether the task-irrelevant sounds were low or high frequency. Using event-related potential (ERP), audiovisual integration was found over the occipital area for 0.5 kHz auditory stimuli from 190-210 ms, for 1 kHz stimuli from 170-200 ms, for 2.5 kHz stimuli from 140-200 ms, 5 kHz stimuli from 100-200 ms. These findings suggest that a higher frequency sound signal paired with visual stimuli might be early processed or integrated despite the auditory stimuli being task-irrelevant information. Furthermore, audiovisual integration in late latency (300-340 ms) ERPs with fronto-central topography was found for auditory stimuli of lower frequencies (0.5, 1 and 2.5 kHz). Our results confirmed that audiovisual integration is affected by the frequency of an auditory stimulus. Taken together, the neurophysiological results provide unique insight into how the brain processes a multisensory visual signal and auditory stimuli of different frequencies.

  15. Auditory stream segregation using bandpass noises: evidence from event-related potentials

    Directory of Open Access Journals (Sweden)

    Yingjiu eNie

    2014-09-01

    Full Text Available The current study measured neural responses to investigate auditory stream segregation of noise stimuli with or without clear spectral contrast. Sequences of alternating A and B noise bursts were presented to elicit stream segregation in normal-hearing listeners. The successive B bursts in each sequence maintained an equal amount of temporal separation with manipulations introduced on the last stimulus. The last B burst was either delayed for 50% of the sequences or not delayed for the other 50%. The A bursts were jittered in between every two adjacent B bursts. To study the effects of spectral separation on streaming, the A and B bursts were further manipulated by using either bandpass-filtered noises widely spaced in center frequency or broadband noises. Event-related potentials (ERPs to the last B bursts were analyzed to compare the neural responses to the delay vs. no-delay trials in both passive and attentive listening conditions. In the passive listening condition, a trend for a possible late mismatch negativity (MMN or late discriminative negativity (LDN response was observed only when the A and B bursts were spectrally separate, suggesting that spectral separation in the A and B burst sequences could be conducive to stream segregation at the pre-attentive level. In the attentive condition, a P300 response was consistently elicited regardless of whether there was spectral separation between the A and B bursts, indicating the facilitative role of voluntary attention in stream segregation. The results suggest that reliable ERP measures can be used as indirect indicators for auditory stream segregation in conditions of weak spectral contrast. These findings have important implications for cochlear implant (CI studies – as spectral information available through a CI device or simulation is substantially degraded, it may require more attention to achieve stream segregation.

  16. Disentangling the Attention Network Test: Behavioral, Event Related Potentials and neural source analyses.

    Directory of Open Access Journals (Sweden)

    Alejandro eGalvao-Carmona

    2014-10-01

    Full Text Available Background. The study of the attentional system remains a challenge for current neuroscience. The Attention Network Test (ANT was designed to study simultaneously three different attentional networks (alerting, orienting and executive based in subtraction of different experimental conditions. However, some studies recommend caution with these calculations due to the interactions between the attentional networks. In particular, it is highly relevant that several interpretations about attentional impairment have arisen from these calculations in diverse pathologies. Event Related Potentials (ERPs and neural source analysis can be applied to disentangle the relationships between these attentional networks not specifically shown by behavioural measures. Results. This study shows that there is a basic level of alerting (tonic alerting in the no cue condition, represented by a slow negative trend in the ERP trace prior to the onset of the target stimuli. A progressive increase in the CNV amplitude related to the amount of information provided by the cue conditions is also shown. Neural source analysis reveals specific modulations of the CNV related to a task-related expectancy presented in the no cue condition; a late modulation triggered by the central cue condition and probably representing a generic motor preparation; and an early and late modulation for spatial cue condition suggesting specific motor and sensory preactivation. Finally, the first component in the information processing of the target stimuli modulated by the interaction between orienting network and the executive system can be represented by N1. Conclusions. The ANT is useful as a paradigm to study specific attentional mechanisms and their interactions. However, calculation of network effects is based in subtractions with non-comparable experimental conditions, as evidenced by the present data, which can induce misinterpretations in the study of the attentional capacity in human

  17. The development of control processes supporting source memory discrimination as revealed by event-related potentials.

    Science.gov (United States)

    de Chastelaine, Marianne; Friedman, David; Cycowicz, Yael M

    2007-08-01

    Improvement in source memory performance throughout childhood is thought to be mediated by the development of executive control. As postretrieval control processes may be better time-locked to the recognition response rather than the retrieval cue, the development of processes underlying source memory was investigated with both stimulus- and response-locked event-related potentials (ERPs). These were recorded in children, adolescents, and adults during a recognition memory exclusion task. Green- and red-outlined pictures were studied, but were tested in black outline. The test requirement was to endorse old items shown in one study color ("targets") and to reject new items along with old items shown in the alternative study color ("nontargets"). Source memory improved with age. All age groups retrieved target and nontarget memories as reflected by reliable parietal episodic memory (EM) effects, a stimulus-locked ERP correlate of recollection. Response-locked ERPs to targets and nontargets diverged in all groups prior to the response, although this occurred at an increasingly earlier time point with age. We suggest these findings reflect the implementation of attentional control mechanisms to enhance target memories and facilitate response selection with the greatest and least success, respectively, in adults and children. In adults only, response-locked ERPs revealed an early-onsetting parietal negativity for nontargets, but not for targets. This was suggested to reflect adults' ability to consistently inhibit prepotent target responses for nontargets. The findings support the notion that the development of source memory relies on the maturation of control processes that serve to enhance accurate selection of task-relevant memories.

  18. Who Are the True Fans? Evidence from an Event-Related Potential Study.

    Science.gov (United States)

    Ma, Qingguo; Jin, Jia; Yuan, Ruixian; Zhang, Wuke

    2015-01-01

    Fans of celebrities commonly exist in modern society. Researchers from social science have been concerned with this problem for years. Furthermore, such researchers have attempted to measure people's involvement with celebrities in various ways. However, no study measured the degree of addiction to a specific celebrity at the neurological level. Therefore, the current study employed visually evoked event related potentials (ERPs) to examine people's attitude toward celebrities by comparing different brain activities of fans and non-fans when they were shown a set of photos. These photos include a specific celebrity, a familiar person, a stranger and a butterfly. Furthermore, to examine the validity of the detected neural index, we also investigated the correlation between brain activity and the score of the Celebrity Attitude Scale (CAS), which was a questionnaire used to explore people's attitude toward celebrities at behavioral level. Two groups of subjects were asked to complete an implicit task, i.e., to press a button when a picture of a butterfly appeared. Results revealed that fans showed significant positive N2 and P300 deflection when viewing the photos of their favorite celebrity, whereas in the non-fan group, the subjects only showed larger P300 amplitude as a response to the celebrity's photos. Furthermore, a positive correlation between P300 amplitude elicited by the stimuli of a celebrity face and CAS scores was also observed. These findings indicated fan attitude to a specific celebrity can also be observed at the neurological level and suggested the potential utility of using ERP component as an index of fandom involvement.

  19. Event-related potential studies of outcome processing and feedback-guided learning

    Directory of Open Access Journals (Sweden)

    René eSan Martín

    2012-11-01

    Full Text Available In order to control behavior in an adaptive manner the brain has to learn how some situations and actions predict positive or negative outcomes. During the last decade cognitive neuroscientists have shown that the brain is able to evaluate and learn from outcomes within a few hundred milliseconds of their occurrence. This research has been primarily focused on the feedback-related negativity (FRN and the P3, two event-related potential (ERP components that are elicited by outcomes. The FRN is a frontally distributed negative-polarity ERP component that typically reaches its maximal amplitude 250 ms after outcome presentation and tends to be larger for negative than for positive outcomes. The FRN has been associated with activity in the anterior cingulate cortex. The P3 (~300-600 ms is a parietally distributed positive-polarity ERP component that tends to be larger for large magnitude than for small magnitude outcomes. The neural sources of the P3 are probably distributed over different regions of the cortex. This paper examines the theories that have been proposed to explain the functional role of these two ERP components during outcome processing. Special attention is paid to extant literature addressing how these ERP components are modulated by outcome valence (negative vs. positive, outcome magnitude (large vs. small, outcome probability (unlikely vs. likely and behavioral adjustment. The literature offers few generalizable conclusions, but is beset with a number of inconsistencies across studies. This paper discusses the potential reasons for these inconsistencies and points out some challenges that will shape the field over the next decade.

  20. Cognitive deficits following exposure to pneumococcal meningitis: an event-related potential study

    Directory of Open Access Journals (Sweden)

    Kihara Michael

    2012-03-01

    Full Text Available Abstract Background Pneumococcal meningitis (PM is a severe and life-threatening disease that is associated with cognitive impairment including learning difficulties, cognitive slowness, short-term memory deficits and poor academic performance. There are limited data on cognitive outcomes following exposure to PM from Africa mainly due to lack of culturally appropriate tools. We report cognitive processes of exposed children as measured by auditory and visual event-related potentials. Methods Sixty-five children (32 male, mean 8.4 years, SD 3.0 years aged between 4-15 years with a history of PM and an age-matched control group of 93 children (46 male; mean 8.4 years, SD 2.7 years were recruited from a well-demarcated study area in Kilifi. In the present study, both baseline to peak and peak-to-peak amplitude differences are reported. Results Children with a history of pneumococcal meningitis had significantly longer auditory P1 and P3a latencies and smaller P1 amplitudes compared to unexposed children. In the visual paradigm, children with PM seemingly lacked a novelty P3a component around 350 ms where control children had a maximum, and showed a lack of stimulus differentiation at Nc. Further, children with exposure to PM had smaller peak to peak amplitude (N2-P1 compared to unexposed children. Conclusion The results suggest that children with a history of PM process novelty differently than do unexposed children, with slower latencies and reduced or absent components. This pattern suggests poorer auditory attention and/or cognitive slowness and poorer visual attention orienting, possibly due to disruption in the functions of the lateral prefrontal and superior temporal cortices. ERPs may be useful for assessment of the development of perceptual-cognitive functions in post brain-injury in African children by providing an alternate way of assessing cognitive development in patient groups for whom more typical standardized neuropsychological

  1. Statistical analysis of events related to emergency diesel generators failures in the nuclear industry

    International Nuclear Information System (INIS)

    Kančev, Duško; Duchac, Alexander; Zerger, Benoit; Maqua, Michael; Wattrelos, Didier

    2014-01-01

    Highlights: • Analysis of operating experience related to emergency diesel generators events at NPPs. • Four abundant operating experience databases screened. • Delineating important insights and conclusions based on the operating experience. - Abstract: This paper is aimed at studying the operating experience related to emergency diesel generators (EDGs) events at nuclear power plants collected from the past 20 years. Events related to EDGs failures and/or unavailability as well as all the supporting equipment are in the focus of the analysis. The selected operating experience was analyzed in detail in order to identify the type of failures, attributes that contributed to the failure, failure modes potential or real, discuss risk relevance, summarize important lessons learned, and provide recommendations. The study in this particular paper is tightly related to the performing of statistical analysis of the operating experience. For the purpose of this study EDG failure is defined as EDG failure to function on demand (i.e. fail to start, fail to run) or during testing, or an unavailability of an EDG, except of unavailability due to regular maintenance. The Gesellschaft für Anlagen und Reaktorsicherheit mbH (GRS) and Institut de Radioprotection et de Sûreté Nucléaire (IRSN) databases as well as the operating experience contained in the IAEA/NEA International Reporting System for Operating Experience and the U.S. Licensee Event Reports were screened. The screening methodology applied for each of the four different databases is presented. Further on, analysis aimed at delineating the causes, root causes, contributing factors and consequences are performed. A statistical analysis was performed related to the chronology of events, types of failures, the operational circumstances of detection of the failure and the affected components/subsystems. The conclusions and results of the statistical analysis are discussed. The main findings concerning the testing

  2. Multivariate evaluation of brain function by measuring regional cerebral blood flow and event-related potentials

    Energy Technology Data Exchange (ETDEWEB)

    Koga, Yoshihiko; Mochida, Masahiko; Shutara, Yoshikazu; Nakagawa, Kazumi [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine; Nagata, Ken

    1998-07-01

    To measure the effect of events on human cognitive function, effects of odors by measurement regional cerebral blood flow (rCBF) and P300 were evaluated during the auditory odd-ball exercise. PET showed the increase in rCBF on the right hemisphere of the brain by coffee aroma. rCBF was measured by PET in 9 of right-handed healthy adults men, and P300 was by event-related potential (ERP) in each sex of 20 right-handed healthy adults. ERP showed the difference of the P300 amplitude between men and women, and showed the tendency, by odors except the lavender oil, that women had higher in the P300 amplitude than men. These results suggest the presence of effects on the cognitive function through emotional actions. Next, the relationship between rCBF and ERP were evaluated. The subjects were 9 of the right-handed healthy adults (average: 25.6{+-}3.4 years old). rCBF by PET and P300 amplitude by ERP were simultaneously recorded during the auditory odd-ball exercise using the tone-burst method (2 kHz of the low frequency aimed stimuli and 1 kHz of the high frequency non-aimed stimuli). The rCBF value was the highest at the transverse gyrus of Heschl and the lowest at the piriform cortex among 24 regions of interest (ROI) from both sides. The difference of P300 peak latent time among ROI was almost the same. The brain waves from Cz and Pz were similar and the average amplitude was highest at Pz. We found the high correlation in the right piriform cortex (Fz), and right (Fz, Cz) and left (Cz, Pz) transverse gyrus of Heschl between the P300 amplitude and rCBF. (K.H.)

  3. Competitive Semantic Memory Retrieval: Temporal Dynamics Revealed by Event-Related Potentials.

    Science.gov (United States)

    Hellerstedt, Robin; Johansson, Mikael

    2016-01-01

    Memories compete for retrieval when they are related to a common retrieval cue. Previous research has shown that retrieval of a target memory may lead to subsequent retrieval-induced forgetting (RIF) of currently irrelevant competing memories. In the present study, we investigated the time course of competitive semantic retrieval and examined the neurocognitive mechanisms underlying RIF. We contrasted two theoretical accounts of RIF by examining a critical aspect of this memory phenomenon, namely the extent to which it depends on successful retrieval of the target memory. Participants first studied category-exemplar word-pairs (e.g. Fruit-Apple). Next, we recorded electrophysiological measures of brain activity while the participants performed a competitive semantic cued-recall task. In this task, the participants were provided with the studied categories but they were instructed to retrieve other unstudied exemplars (e.g. Fruit-Ma__?). We investigated the event-related potential (ERP) correlates of retrieval success by comparing ERPs from successful and failed retrieval trials. To isolate the ERP correlates of continuous retrieval attempts from the ERP correlates of retrieval success, we included an impossible retrieval condition, with incompletable word-stem cues (Drinks-Wy__) and compared it with a non-retrieval presentation baseline condition (Occupation-Dentist). The participants' memory for all the studied exemplars was tested in the final phase of the experiment. Taken together, the behavioural results suggest that RIF is independent of target retrieval. Beyond investigating the mechanisms underlying RIF, the present study also elucidates the temporal dynamics of semantic cued-recall by isolating the ERP correlates of retrieval attempt and retrieval success. The ERP results revealed that retrieval attempt is reflected in a late posterior negativity, possibly indicating construction of candidates for completing the word-stem cue and retrieval monitoring

  4. Bilateral theta-burst magnetic stimulation influence on event-related brain potentials.

    Science.gov (United States)

    Pinto, Nuno; Duarte, Marta; Gonçalves, Helena; Silva, Ricardo; Gama, Jorge; Pato, Maria Vaz

    2018-01-01

    Theta-burst stimulation (TBS) can be a non-invasive technique to modulate cognitive functions, with promising therapeutic potential, but with some contradictory results. Event related potentials are used as a marker of brain deterioration and can be used to evaluate TBS-related cognitive performance, but its use remains scant. This study aimed to study bilateral inhibitory and excitatory TBS effects upon neurocognitive performance of young healthy volunteers, using the auditory P300' results. Using a double-blind sham-controlled study, 51 healthy volunteers were randomly assigned to five different groups, two submitted to either excitatory (iTBS) or inhibitory (cTBS) stimulation over the left dorsolateral pre-frontal cortex (DLPFC), two other actively stimulated the right DLPFC and finally a sham stimulation group. An oddball based auditory P300 was performed just before a single session of iTBS, cTBS or sham stimulation and repeated immediately after. P300 mean latency comparison between the pre- and post-TBS stimulation stages revealed significantly faster post stimulation latencies only when iTBS was performed on the left hemisphere (p = 0.003). Right and left hemisphere cTBS significantly delayed P300 latency (right p = 0.026; left p = 0.000). Multiple comparisons for N200 showed slower latencies after iTBS over the right hemisphere. No significant difference was found in amplitude variation. TBS appears to effectively influence neural networking involved in P300 formation, but effects seem distinct for iTBS vs cTBS and for the right or the left hemisphere. P300 evoked potentials can be an effective and practical tool to evaluate transcranial magnetic stimulation related outcomes.

  5. Double dissociation between rules and memory in music: an event-related potential study.

    Science.gov (United States)

    Miranda, Robbin A; Ullman, Michael T

    2007-11-01

    Language and music share a number of characteristics. Crucially, both domains depend on both rules and memorized representations. Double dissociations between the neurocognition of rule-governed and memory-based knowledge have been found in language but not music. Here, the neural bases of both of these aspects of music were examined with an event-related potential (ERP) study of note violations in melodies. Rule-only violations consisted of out-of-key deviant notes that violated tonal harmony rules in novel (unfamiliar) melodies. Memory-only violations consisted of in-key deviant notes in familiar well-known melodies; these notes followed musical rules but deviated from the actual melodies. Finally, out-of-key notes in familiar well-known melodies constituted violations of both rules and memory. All three conditions were presented, within-subjects, to healthy young adults, half musicians and half non-musicians. The results revealed a double dissociation, independent of musical training, between rules and memory: both rule violation conditions, but not the memory-only violations, elicited an early, somewhat right-lateralized anterior-central negativity (ERAN), consistent with previous studies of rule violations in music, and analogous to the early left-lateralized anterior negativities elicited by rule violations in language. In contrast, both memory violation conditions, but not the rule-only violation, elicited a posterior negativity that might be characterized as an N400, an ERP component that depends, at least in part, on the processing of representations stored in long-term memory, both in language and in other domains. The results suggest that the neurocognitive rule/memory dissociation extends from language to music, further strengthening the similarities between the two domains.

  6. Sex differences in event-related potentials and attentional biases to emotional facial stimuli

    Directory of Open Access Journals (Sweden)

    Daniela M. Pfabigan

    2014-12-01

    Full Text Available Attentional processes play an important role in the processing of emotional information. Previous research reported attentional biases during stimulus processing in anxiety and depression. However, sex differences in the processing of emotional stimuli and higher prevalence rates of anxiety disorders among women, compared to men, suggest that attentional biases may also differ between the two sexes. The present study used a modified version of the dot probe task with happy, angry, and neutral facial stimuli to investigate the time course of attentional biases in healthy volunteers. Moreover, associations of attentional biases with alexithymia were examined on the behavioral and physiological level. Event-related potentials were measured while 21 participants (11 women performed the task, utilizing also for the first time a difference wave approach in the analysis to highlight emotion-specific aspects. Women showed overall enhanced probe P1 amplitudes compared to men, in particular after rewarding facial stimuli. Under the difference wave approach, probe P1 amplitudes appeared specifically enhanced with regard to congruently presented happy facial stimuli among women, compared to men. Both methods yielded enhanced probe P1 amplitudes after presentation of the emotional stimulus in the left compared to the right visual hemifield. Probe P1 amplitudes correlated negatively with self-reported alexithymia, most of these correlations were only observable in women. Our results suggest that women orient their attention to a greater extent to facial stimuli than men and corroborate that alexithymia is a correlate of reduced emotional reactivity on a neuronal level. We recommend using a difference wave approach when addressing attentional processes of orientation and disengagement also in future studies.

  7. Multivariate evaluation of brain function by measuring regional cerebral blood flow and event-related potentials

    International Nuclear Information System (INIS)

    Koga, Yoshihiko; Mochida, Masahiko; Shutara, Yoshikazu; Nakagawa, Kazumi; Nagata, Ken

    1998-01-01

    To measure the effect of events on human cognitive function, effects of odors by measurement regional cerebral blood flow (rCBF) and P300 were evaluated during the auditory odd-ball exercise. PET showed the increase in rCBF on the right hemisphere of the brain by coffee aroma. rCBF was measured by PET in 9 of right-handed healthy adults men, and P300 was by event-related potential (ERP) in each sex of 20 right-handed healthy adults. ERP showed the difference of the P300 amplitude between men and women, and showed the tendency, by odors except the lavender oil, that women had higher in the P300 amplitude than men. These results suggest the presence of effects on the cognitive function through emotional actions. Next, the relationship between rCBF and ERP were evaluated. The subjects were 9 of the right-handed healthy adults (average: 25.6±3.4 years old). rCBF by PET and P300 amplitude by ERP were simultaneously recorded during the auditory odd-ball exercise using the tone-burst method (2 kHz of the low frequency aimed stimuli and 1 kHz of the high frequency non-aimed stimuli). The rCBF value was the highest at the transverse gyrus of Heschl and the lowest at the piriform cortex among 24 regions of interest (ROI) from both sides. The difference of P300 peak latent time among ROI was almost the same. The brain waves from Cz and Pz were similar and the average amplitude was highest at Pz. We found the high correlation in the right piriform cortex (Fz), and right (Fz, Cz) and left (Cz, Pz) transverse gyrus of Heschl between the P300 amplitude and rCBF. (K.H.)

  8. Extending or creating a new brand: evidence from a study on event-related potentials.

    Science.gov (United States)

    Jin, Jia; Wang, Cuicui; Yu, Liping; Ma, Qingguo

    2015-07-08

    Brand strategy is a critical problem in new product promotion. In relation to this, producers typically have two main options, namely, brand extension and new brand creation. The current study investigated the neural basis of evaluating these brand strategies at the brain level by using event-related potentials. The experiment used a word-pair paradigm, in which the first word was either a famous beverage brand name or a newly created brand, and the second word was a product name from one of the two product categories (beverage or household appliance). Therefore, four conditions existed as follows: a famous beverage brand paired with a beverage product (BB) or with a household appliance (BH) and a newly created brand paired with a beverage product (NB) or with a household appliance (NH). Behavioral results showed that brand extension obtained a higher acceptance rate than new brand creation under the beverage product category; however, a lower acceptance rate was observed under the household appliance category. Moreover, at the brain level, BB elicited lower N400 mean amplitude than the new brand product NB, whereas BH led to higher N400 amplitude than the new brand product NH. These results showed that the likelihood of accepting a product depended on the association between the brand name and product name, and that the N400 could serve as an index of brand strategy evaluation. In addition, this study also confirmed that brand extension is not always the best brand strategy; an inappropriate extension sometimes performed worse than the creation of a new brand.

  9. Pleasant and unpleasant odors influence hedonic evaluations of human faces: an event-related potential study.

    Directory of Open Access Journals (Sweden)

    Stephanie Jane Cook

    2015-12-01

    Full Text Available Odors can alter hedonic evaluations of human faces, but the neural mechanisms of such effects are poorly understood. The present study aimed to analyze the neural underpinning of odor-induced changes in evaluations of human faces in an odor-priming paradigm, using event-related potentials (ERPs. Healthy, young participants (N = 20 rated neutral faces presented after a three second pulse of a pleasant odor (jasmine, unpleasant odor (methylmercaptan, or no-odor control (clean air. Neutral faces presented in the pleasant odor condition were rated more pleasant than the same faces presented in the no-odor control condition, which in turn were rated more pleasant than faces in the unpleasant odor condition. Analysis of face-related potentials revealed four clusters of electrodes significantly affected by odor condition at specific time points during long-latency epochs (600−950 ms. In the 620−640 ms interval, two scalp-time clusters showed greater negative potential in the right parietal electrodes in response to faces in the pleasant odor condition, compared to those in the no-odor and unpleasant odor conditions. At 926 ms, face-related potentials showed greater positivity in response to faces in the pleasant and unpleasant odor conditions at the left and right lateral frontal-temporal electrodes, respectively. Our data shows that odor-induced shifts in evaluations of faces were associated with amplitude changes in the late (> 600 and ultra-late (> 900 ms latency epochs. The observed amplitude changes during the ultra-late epoch are consistent with a left/right hemisphere bias towards pleasant/unpleasant odor effects. Odors alter evaluations of human faces, even when there is a temporal lag between presentation of odors and faces. Our results provide an initial understanding of the neural mechanisms underlying effects of odors on hedonic evaluations.

  10. Single-shot fluctuations in waveguided high-harmonic generation

    NARCIS (Netherlands)

    Goh, S.J.; Tao, Y.; van der Slot, Petrus J.M.; Bastiaens, Hubertus M.J.; Herek, Jennifer Lynn; Biedron, S.G.; Danailov, M.B.; Milton, S.V.; Boller, Klaus J.

    2015-01-01

    For exploring the application potential of coherent soft x-ray (SXR) and extreme ultraviolet radiation (XUV) provided by high-harmonic generation, it is important to characterize the central output parameters. Of specific importance are pulse-to-pulse (shot-to-shot) fluctuations of the high-harmonic

  11. Quantitative single shot and spatially resolved plasma wakefield diagnostics

    CERN Document Server

    Kasim, Muhammad Firmansyah; Ceurvorst, Luke; Levy, Matthew C; Ratan, Naren; Sadler, James; Bingham, Robert; Burrows, Philip N; Trines, Raoul; Wing, Matthew; Norreys, Peter

    2015-01-01

    Diagnosing plasma conditions can give great advantages in optimizing plasma wakefield accelerator experiments. One possible method is that of photon acceleration. By propagating a laser probe pulse through a plasma wakefield and extracting the imposed frequency modulation, one can obtain an image of the density modulation of the wakefield. In order to diagnose the wakefield parameters at a chosen point in the plasma, the probe pulse crosses the plasma at oblique angles relative to the wakefield. In this paper, mathematical expressions relating the frequency modulation of the laser pulse and the wakefield density profile of the plasma for oblique crossing angles are derived. Multidimensional particle-in-cell simulation results presented in this paper confirm that the frequency modulation profiles and the density modulation profiles agree to within 10%. Limitations to the accuracy of the measurement are discussed in this paper. This technique opens new possibilities to quantitatively diagnose the plasma wakefie...

  12. The challenges of single-shot spinal anaesthesia for cesearean ...

    African Journals Online (AJOL)

    An unusual case of morbid obesity, severe hypertension and twin gestation at 36weeks in an unbooked multigravid patient was presented for cesarean section. She was referred from a private clinic to the obstetric emergency unit of the University College Hospital, Ibadan with history of hypertension in pregnancy. She was ...

  13. Single-shot optical conductivity measurement of dense aluminum plasmas

    International Nuclear Information System (INIS)

    Churina, I. V.; Cho, B.-I.; Bernstein, A.; Stoker, D. S.; Dalton, A.; Symes, D. R.; Ditmire, T.

    2009-01-01

    The optical conductivity of a dense femtosecond laser-heated aluminum plasma heated to 0.1-1.5 eV was measured using frequency-domain interferometry with chirped pulses, permitting simultaneous observation of optical probe reflectivity and probe pulse phase shift. Coupled with published models of bound-electron contributions to the conductivity, these two independent experimental data yielded a direct measurement of both real and imaginary components of the plasma conductivity.

  14. Fronto-limbic dysfunction in response to facial emotion in borderline personality disorder: an event-related fMRI study.

    Science.gov (United States)

    Minzenberg, Michael J; Fan, Jin; New, Antonia S; Tang, Cheuk Y; Siever, Larry J

    2007-08-15

    Clinical hallmarks of borderline personality disorder (BPD) include social and emotional dysregulation. We tested a model of fronto-limbic dysfunction in facial emotion processing in BPD. Groups of 12 unmedicated adults with BPD by DSM-IV and 12 demographically-matched healthy controls (HC) viewed facial expressions (Conditions) of neutral emotion, fear and anger, and made gender discriminations during rapid event-related functional magnetic resonance imaging (fMRI). Analysis of variance of Region of Interest signal change revealed a statistically significant effect of the Group-by-Region-by-Condition interaction. This was due to the BPD group exhibiting a significantly larger magnitude of deactivation (relative to HC) in the bilateral rostral/subgenual anterior cingulate cortex (ACC) to fear and in the left ACC to fear minus neutral; and significantly greater activation in the right amygdala to fear minus neutral. There were no significant between-group differences in ROI signal change in response to anger. In voxel-wise analyses constrained within these ROIs, the BPD group exhibited significant changes in the fear minus neutral contrast, with relatively less activation in the bilateral rostral/subgenual ACC, and greater activation in the right amygdala. In the anger minus neutral contrast this pattern was reversed, with the BPD group showing greater activation in the bilateral rostral/subgenual ACC and less activation in the bilateral amygdala. We conclude that adults with BPD exhibit changes in fronto-limbic activity in the processing of fear stimuli, with exaggerated amygdala response and impaired emotion-modulation of ACC activity. The neural substrates underlying processing of anger may also be altered. These changes may represent an expression of the volumetric and serotonergic deficits observed in these brain areas in BPD.

  15. Verbal Learning and Memory in Cannabis and Alcohol Users: An Event-Related Potential Investigation

    Directory of Open Access Journals (Sweden)

    Janette L. Smith

    2017-12-01

    Full Text Available Aims: Long-term heavy use of cannabis and alcohol are known to be associated with memory impairments. In this study, we used event-related potentials to examine verbal learning and memory processing in a commonly used behavioral task.Method: We conducted two studies: first, a small pilot study of adolescent males, comprising 13 Drug-Naive Controls (DNC, 12 heavy drinkers (HD and 8 cannabis users (CU. Second, a larger study of young adults, comprising 45 DNC (20 female, 39 HD (16 female, and 20 CU (9 female. In both studies, participants completed a modified verbal learning task (the Rey Auditory Verbal Learning Test, RAVLT while brain electrical activity was recorded. ERPs were calculated for words which were subsequently remembered vs. those which were not remembered, and for presentations of learnt words, previously seen words, and new words in a subsequent recognition test. Pre-planned principal components analyses (PCA were used to quantify the ERP components in these recall and recognition phases separately for each study.Results: Memory performance overall was slightly lower than published norms using the standardized RAVLT delivery, but was generally similar and showed the expected changes over trials. Few differences in performance were observed between groups; a notable exception was markedly poorer delayed recall in HD relative to DNC (Study 2. PCA identified components expected from prior research using other memory tasks. At encoding, there were no between-group differences in the usual P2 recall effect (larger for recalled than not-recalled words. However, alcohol-related differences were observed in a larger P540 (indexing recollection in HD than DNC, and cannabis-related differences were observed in a smaller N340 (indexing familiarity and a lack of previously seen > new words effect for P540 in Study 2.Conclusions: This study is the first examination of ERPs in the RAVLT in healthy control participants, as well as substance

  16. Event-related brain potentials in memory: correlates of episodic, semantic and implicit memory.

    Science.gov (United States)

    Wieser, Stephan; Wieser, Heinz Gregor

    2003-06-01

    To study cognitive evoked potentials, recorded from scalp EEG and foramen ovale electrodes, during activation of explicit and implicit memory. The subgroups of explicit memory, episodic and semantic memory, are looked at separately. A word-learning task was used, which has been shown to activate hippocampus in H(2)(15)O positron emission tomography studies. Subjects had to study and remember word pairs using different learning strategies: (i) associative word learning (AWL), which activates the episodic memory, (ii) deep single word encoding (DSWE), which activates the semantic memory, and (iii) shallow single word encoding (SSWE), which activates the implicit memory and serves as a baseline. The test included the 'remember/know' paradigm as a behavioural learning control. During the task condition, a 10-20 scalp EEG with additional electrodes in both temporal lobes regions was recorded from 11 healthy volunteers. In one patient with mesiotemporal lobe epilepsy, the EEG was recorded from bilateral foramen ovale electrodes directly from mesial temporal lobe structures. Event-related potentials (ERPs) were calculated off-line and visual and statistical analyses were made. Associative learning strategy produced the best memory performance and the best noetic awareness experience, whereas shallow single word encoding produced the worst performance and the smallest noetic awareness. Deep single word encoding performance was in between. ERPs differed according to the test condition, during both encoding and retrieval, from both the scalp EEG and the foramen ovale electrode recordings. Encoding showed significant differences between the shallow single word encoding (SSWE), which is mainly a function of graphical characteristics, and the other two strategies, deep single word (DSWE) and associative learning (AWL), in which there is a semantic processing of the meaning. ERPs generated by these two categories, which are both functions of explicit memory, differed as well

  17. Event-Related Potential Measures of Attention Capture in Adolescent Inpatients With Acute Suicidal Behavior.

    Science.gov (United States)

    Tavakoli, Paniz; Boafo, Addo; Dale, Allyson; Robillard, Rebecca; Greenham, Stephanie L; Campbell, Kenneth

    2018-01-01

    Impaired executive functions, modulated by the frontal lobes, have been suggested to be associated with suicidal behavior. The present study examines one of these executive functions, attentional control, maintaining attention to the task-at-hand. A group of inpatient adolescents with acute suicidal behavior and healthy controls were studied using a passively presented auditory optimal paradigm. This "optimal" paradigm consisted of a series of frequently presented homogenous pure tone "standards" and different "deviants," constructed by changing one or more features of the standard. The optimal paradigm has been shown to be a more time-efficient replacement to the traditional oddball paradigm, which makes it suitable for use in clinical populations. The extent of processing of these "to-be-ignored" auditory stimuli was measured by recording event-related potentials (ERPs). The P3a ERP component is thought to reflect processes associated with the capturing of attention. Rare and novel stimuli may result in an executive decision to switch attention away from the current cognitive task and toward a probe of the potentially more relevant "interrupting" auditory input. On the other hand, stimuli that are quite similar to the standard should not elicit P3a. The P3a has been shown to be larger in immature brains in early compared to later adolescence. An overall enhanced P3a was observed in the suicidal group. The P3a was larger in this group for both the environmental sound and white noise deviants, although only the environmental sound P3a attained significance. Other deviants representing only a small change from the standard did not elicit a P3a in healthy controls. They did elicit a small P3a in the suicidal group. These findings suggest a lowered threshold for the triggering of the involuntary switch of attention in these patients, which may play a role in their reported distractibility. The enhanced P3a is also suggestive of an immature frontal central executive

  18. Event-related potentials as a measure of sleep disturbance: A tutorial review

    Directory of Open Access Journals (Sweden)

    Kenneth Campbell

    2010-01-01

    Full Text Available This article reviews event-related potentials (ERPs the minute responses of the human brain that are elicited by external auditory stimuli and how the ERPs can be used to measure sleep disturbance. ERPs consist of a series of negative- and positive-going components. A negative component peaking at about 100 ms, N1, is thought to reflect the outcome of a transient detector system, activated by change in the transient energy in an acoustic stimulus. Its output and thus the amplitude of N1 increases as the intensity level of the stimulus is increased and when the rate of presentation is slowed. When the output reaches a certain critical level, operations of the central executive are interrupted and attention is switched to the auditory channel. This switching of attention is thought to be indexed by a later positivity, P3a, peaking between 250 and 300 ms. In order to sleep, consciousness for all but the most relevant of stimuli must be prevented. Thus, during sleep onset and definitive non-rapid eye movement (NREM sleep, the amplitude of N1 diminishes to near-baseline level. The amplitude of P2, peaking from 180 to 200 ms, is however larger in NREM sleep than in wakefulness. P2 is thought to reflect an inhibitory process protecting sleep from irrelevant disturbance. As stimulus input becomes increasingly obtrusive, the amplitude of P2 also increases. With increasing obtrusiveness particularly when stimuli are presented slowly, a later large negativity, peaking at about 350 ms, N350, becomes apparent. N350 is unique to sleep, its amplitude also increasing as the stimulus becomes more obtrusive. Many authors postulate that when the N350 reaches a critical amplitude, a very large amplitude N550, a component of the K-Complex is elicited. The K-Complex can only be elicited during NREM sleep. The P2, N350 and N550 processes are thus conceived as sleep protective mechanisms, activated sequentially as the risk for disturbance increases. During REM sleep

  19. Event-related cortical processing in neuropathic pain under long-term spinal cord stimulation.

    Science.gov (United States)

    Weigel, Ralf; Capelle, H Holger; Flor, Herta; Krauss, Joachim K

    2015-01-01

    Several mechanisms were suggested in the past to explain the beneficial effect of spinal cord stimulation (SCS) in patients suffering from neuropathic pain. Little is known about potential supraspinal mechanisms. In this study cortical signaling of patients with neuropathic pain and successful long-term treatment with SCS was analyzed. Observational study. University hospital, neurosurgical department, outpatient clinic for movement disorders and pain, institute for cognitive and clinical neuroscience. Nine patients with neuropathic pain of a lower extremity with a lasting response to chronic SCS were included. Cortical activity was analyzed using event-related potentials of the electroencephalogram after non-painful and painful stimulation. Each patient was tested under the effect of long-term SCS and 24 hours after cessation of SCS. Cortical areas involved in the peaks of evoked potentials were localized using a source localization method based on a fixed dipole model. Detection threshold and intensity of non-painful stimulation did not differ significantly on both sides. Pain threshold was significantly lower on the neuropathic side under the effect of SCS (P = 0.03). Bilateral pain thresholds were significantly lower (P = 0.03 healthy side, P = 0.003 neuropathic side) in 5 patients with increased pain after cessation of SCS. Under the effect of SCS cortical negativities (N1, N2, N3) and positivities (P1) demonstrated bilaterally comparable amplitudes. After cessation of SCS, decreased threshold for peripheral stimulation resulted in lowered negativities on both sides. The positivity P1 was differentially regulated and was reduced more contralateral to the unaffected side. N2 was localized at the sensory representation of the leg within the homunculus. The main vector of P1 was localized within the cingular cortex (CC) and moved more anteriorly under the effect of SCS. The exact time span that SCS continues to have an effect is not known. However, due to patient

  20. A new method to detect event-related potentials based on Pearson's correlation.

    Science.gov (United States)

    Giroldini, William; Pederzoli, Luciano; Bilucaglia, Marco; Melloni, Simone; Tressoldi, Patrizio

    2016-12-01

    Event-related potentials (ERPs) are widely used in brain-computer interface applications and in neuroscience.  Normal EEG activity is rich in background noise, and therefore, in order to detect ERPs, it is usually necessary to take the average from multiple trials to reduce the effects of this noise.  The noise produced by EEG activity itself is not correlated with the ERP waveform and so, by calculating the average, the noise is decreased by a factor inversely proportional to the square root of N , where N is the number of averaged epochs. This is the easiest strategy currently used to detect ERPs, which is based on calculating the average of all ERP's waveform, these waveforms being time- and phase-locked.  In this paper, a new method called GW6 is proposed, which calculates the ERP using a mathematical method based only on Pearson's correlation. The result is a graph with the same time resolution as the classical ERP and which shows only positive peaks representing the increase-in consonance with the stimuli-in EEG signal correlation over all channels.  This new method is also useful for selectively identifying and highlighting some hidden components of the ERP response that are not phase-locked, and that are usually hidden in the standard and simple method based on the averaging of all the epochs.  These hidden components seem to be caused by variations (between each successive stimulus) of the ERP's inherent phase latency period (jitter), although the same stimulus across all EEG channels produces a reasonably constant phase. For this reason, this new method could be very helpful to investigate these hidden components of the ERP response and to develop applications for scientific and medical purposes. Moreover, this new method is more resistant to EEG artifacts than the standard calculations of the average and could be very useful in research and neurology.  The method we are proposing can be directly used in the form of a process written in the well

  1. Event-Related Potential Measures of Attention Capture in Adolescent Inpatients With Acute Suicidal Behavior

    Directory of Open Access Journals (Sweden)

    Paniz Tavakoli

    2018-03-01

    Full Text Available Impaired executive functions, modulated by the frontal lobes, have been suggested to be associated with suicidal behavior. The present study examines one of these executive functions, attentional control, maintaining attention to the task-at-hand. A group of inpatient adolescents with acute suicidal behavior and healthy controls were studied using a passively presented auditory optimal paradigm. This “optimal” paradigm consisted of a series of frequently presented homogenous pure tone “standards” and different “deviants,” constructed by changing one or more features of the standard. The optimal paradigm has been shown to be a more time-efficient replacement to the traditional oddball paradigm, which makes it suitable for use in clinical populations. The extent of processing of these “to-be-ignored” auditory stimuli was measured by recording event-related potentials (ERPs. The P3a ERP component is thought to reflect processes associated with the capturing of attention. Rare and novel stimuli may result in an executive decision to switch attention away from the current cognitive task and toward a probe of the potentially more relevant “interrupting” auditory input. On the other hand, stimuli that are quite similar to the standard should not elicit P3a. The P3a has been shown to be larger in immature brains in early compared to later adolescence. An overall enhanced P3a was observed in the suicidal group. The P3a was larger in this group for both the environmental sound and white noise deviants, although only the environmental sound P3a attained significance. Other deviants representing only a small change from the standard did not elicit a P3a in healthy controls. They did elicit a small P3a in the suicidal group. These findings suggest a lowered threshold for the triggering of the involuntary switch of attention in these patients, which may play a role in their reported distractibility. The enhanced P3a is also suggestive of

  2. The development of prospective memory (PM across adolescence: An Event-related potential analysis.

    Directory of Open Access Journals (Sweden)

    Candice eBowman

    2015-06-01

    Full Text Available Prospective memory (PM is an important cognitive function vital for day-to-day functioning. Although there has been extensive research into the decline of PM in older adulthood, little is known about its developmental trajectory throughout adolescence, a time of important brain maturation. In the present study, the development of PM was examined in 85 participants across the following groups: 12 to 13-year-olds (n = 19, 14 to 15-year-olds (n = 21, 16 to 17-year-olds (n = 19, and 18 to 19-year-olds (n = 26. A 30-cue (30 minute event-based PM task (with font-colour stimuli as PM cues and a lexical-decision task as the ongoing task was used while recording Event-Related Potentials (ERPs. The well-established neural correlates of PM, the N300 and parietal positivity, were examined across the age groups. In addition, hierarchical multiple regressions were used to examine the unique contribution of executive functioning measures (viz., the Self-Ordered Pointing Task [SOPT], the Stroop task, and Trail Making Test [TMT] on the ERP components of PM (after controlling for age. First, the established components of ERPs associated with prospective remembering (i.e., N300 and parietal positivity were detected for each age group. Second, although there were no significant age- group differences on the amplitude of the N300, the amplitude of the parietal positivity was found to be different between the 12 to 13-year-olds and 18 to 19-year-olds (viz., the 12 to 13-year-olds had the highest amplitude. Third, for the contribution of executive functioning measures on the amplitude of the ERP components of PM, the regression on the N300 was not significant, however, the SOPT beta weights were significant predictors of the amplitude of the parietal positivity. This relationship was found to be specific for the central and right electrode region. These findings are discussed within the context of brain development and executive functioning along with particular task

  3. Plant fibre composites - porosity and volumetric interaction

    DEFF Research Database (Denmark)

    Madsen, Bo; Thygesen, Anders; Lilholt, Hans

    2007-01-01

    the combination of a high fibre volume fraction, a low porosity and a high composite density is optimal. Experimental data from the literature on volumetric composition and density of four types of plant fibre composites are used to validate the model. It is demonstrated that the model provides a concept......Plant fibre composites contain typically a relative large amount of porosity, which considerably influences properties and performance of the composites. The large porosity must be integrated in the conversion of weight fractions into volume fractions of the fibre and matrix parts. A model...... is presented to predict the porosity as a function of the fibre weight fractions, and to calculate the related fibre and matrix volume fractions, as well as the density of the composite. The model predicts two cases of composite volumetric interaction separated by a transition fibre weight fraction, at which...

  4. Combined surface and volumetric occlusion shading

    KAUST Repository

    Schott, Matthias O.; Martin, Tobias; Grosset, A. V Pascal; Brownlee, Carson; Hollt, Thomas; Brown, Benjamin P.; Smith, Sean T.; Hansen, Charles D.

    2012-01-01

    In this paper, a method for interactive direct volume rendering is proposed that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The proposed algorithm extends the recently proposed Directional Occlusion Shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. © 2012 IEEE.

  5. Combined surface and volumetric occlusion shading

    KAUST Repository

    Schott, Matthias O.

    2012-02-01

    In this paper, a method for interactive direct volume rendering is proposed that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The proposed algorithm extends the recently proposed Directional Occlusion Shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. © 2012 IEEE.

  6. Volumetric and superficial characterization of carbon activated

    International Nuclear Information System (INIS)

    Carrera G, L.M.; Garcia S, I.; Jimenez B, J.; Solache R, M.; Lopez M, B.; Bulbulian G, S.; Olguin G, M.T.

    2000-01-01

    The activated carbon is the resultant material of the calcination process of natural carbonated materials as coconut shells or olive little bones. It is an excellent adsorbent of diluted substances, so much in colloidal form, as in particles form. Those substances are attracted and retained by the carbon surface. In this work is make the volumetric and superficial characterization of activated carbon treated thermically (300 Centigrade) in function of the grain size average. (Author)

  7. Volumetric polymerization shrinkage of contemporary composite resins

    OpenAIRE

    Nagem Filho, Halim; Nagem, Haline Drumond; Francisconi, Paulo Afonso Silveira; Franco, Eduardo Batista; Mondelli, Rafael Francisco Lia; Coutinho, Kennedy Queiroz

    2007-01-01

    The polymerization shrinkage of composite resins may affect negatively the clinical outcome of the restoration. Extensive research has been carried out to develop new formulations of composite resins in order to provide good handling characteristics and some dimensional stability during polymerization. The purpose of this study was to analyze, in vitro, the magnitude of the volumetric polymerization shrinkage of 7 contemporary composite resins (Definite, Suprafill, SureFil, Filtek Z250, Fill ...

  8. Does erotic stimulus presentation design affect brain activation patterns? Event-related vs. blocked fMRI designs.

    Science.gov (United States)

    Bühler, Mira; Vollstädt-Klein, Sabine; Klemen, Jane; Smolka, Michael N

    2008-07-22

    Existing brain imaging studies, investigating sexual arousal via the presentation of erotic pictures or film excerpts, have mainly used blocked designs with long stimulus presentation times. To clarify how experimental functional magnetic resonance imaging (fMRI) design affects stimulus-induced brain activity, we compared brief event-related presentation of erotic vs. neutral stimuli with blocked presentation in 10 male volunteers. Brain activation differed depending on design type in only 10% of the voxels showing task related brain activity. Differences between blocked and event-related stimulus presentation were found in occipitotemporal and temporal regions (Brodmann Area (BA) 19, 37, 48), parietal areas (BA 7, 40) and areas in the frontal lobe (BA 6, 44). Our results suggest that event-related designs might be a potential alternative when the core interest is the detection of networks associated with immediate processing of erotic stimuli.Additionally, blocked, compared to event-related, stimulus presentation allows the emergence and detection of non-specific secondary processes, such as sustained attention, motor imagery and inhibition of sexual arousal.

  9. Identifying deliberate attempts to fake memory impairment through the combined use of reaction time and event-related potential measures

    NARCIS (Netherlands)

    van Hooff, Johanna C.; Sargeant, Elizabeth; Foster, Jonathan K.; Schmand, Ben A.

    2009-01-01

    The central aim of this study was to evaluate the value of reaction time (RT) measures and event-related potentials (ERPs) for the assessment of simulated memory impairment. In two identical experiments (N = 24), healthy volunteers carried out an adapted version of the Amsterdam Short-Term Memory

  10. The Role of Episodic Memory in Controlled Evaluative Judgments about Attitudes: An Event-Related Potential Study

    Science.gov (United States)

    Johnson, Ray, Jr.; Simon, Elizabeth J.; Henkell, Heather; Zhu, John

    2011-01-01

    Event-related potentials (ERPs) are unique in their ability to provide information about the timing of activity in the neural networks that perform complex cognitive processes. Given the dearth of extant data from normal controls on the question of whether attitude representations are stored in episodic or semantic memory, the goal here was to…

  11. Event-Related fMRI Studies of Episodic Encoding and Retrieval: Meta-Analyses Using Activation Likelihood Estimation

    Science.gov (United States)

    Spaniol, Julia; Davidson, Patrick S. R.; Kim, Alice S. N.; Han, Hua; Moscovitch, Morris; Grady, Cheryl L.

    2009-01-01

    The recent surge in event-related fMRI studies of episodic memory has generated a wealth of information about the neural correlates of encoding and retrieval processes. However, interpretation of individual studies is hampered by methodological differences, and by the fact that sample sizes are typically small. We submitted results from studies of…

  12. The effect of repetition of infrequent familiar and unfamiliar visual patterns on components of the event-related brain potential.

    NARCIS (Netherlands)

    Kok, A.; de Looren de Jong, H.

    1980-01-01

    Examined changes in the waveforms of the event-related brain potential (ERP) during repeated presentations of infrequent-familiar and infrequent-unfamiliar visual patterns; Ss were 12 male university students. The EEG waveforms were averaged separately for each presentation of the 2 types of stimuli

  13. An Event-Related Potential Study of Adolescents' and Young Adults' Judgments of Moral and Social Conventional Violations

    Science.gov (United States)

    Lahat, Ayelet; Helwig, Charles C.; Zelazo, Philip David

    2013-01-01

    The neurocognitive development of moral and conventional judgments was examined. Event-related potentials were recorded while 24 adolescents (13 years) and 30 young adults (20 years) read scenarios with 1 of 3 endings: moral violations, conventional violations, or neutral acts. Participants judged whether the act was acceptable or unacceptable…

  14. Parahippocampal activation during successful recognition of words: a self-paced event-related fMRI study

    NARCIS (Netherlands)

    Daselaar, S. M.; Rombouts, S. A.; Veltman, D. J.; Raaijmakers, J. G.; Lazeron, R. H.; Jonker, C.

    2001-01-01

    In this study, we investigated retrieval from verbal episodic memory using a self-paced event-related fMRI paradigm, similar to the designs typically used in behavioral studies of memory function. We tested the hypothesis that the medial temporal lobe (MTL) is involved in the actual recovery of

  15. Differences between human auditory event-related potentials (AERPs) measured at 2 and 4 months after birth

    NARCIS (Netherlands)

    van den Heuvel, Marion I.; Otte, Renee A.; Braeken, Marijke A. K. A.; Winkler, Istvan; Kushnerenko, Elena; Van den Bergh, Bea R. H.

    2015-01-01

    Infant auditory event-related potentials (AERPs) show a series of marked changes during the first year of life. These AERP changes indicate important advances in early development. The current study examined AERP differences between 2- and 4-month-old infants. An auditory oddball paradigm was

  16. Selective attention and error processing in an illusory conjunction task - An event-related brain potential study

    NARCIS (Netherlands)

    Wijers, AA; Boksem, MAS

    2005-01-01

    We recorded event-related potentials in an illusory conjunction task, in which subjects were cued on each trial to search for a particular colored letter in a subsequently presented test array, consisting of three different letters in three different colors. In a proportion of trials the target

  17. Intelligence and P3 Components of the Event-Related Potential Elicited during an Auditory Discrimination Task with Masking

    Science.gov (United States)

    De Pascalis, V.; Varriale, V.; Matteoli, A.

    2008-01-01

    The relationship between fluid intelligence (indexed by scores on Raven Progressive Matrices) and auditory discrimination ability was examined by recording event-related potentials from 48 women during the performance of an auditory oddball task with backward masking. High ability (HA) subjects exhibited shorter response times, greater response…

  18. Psychometric intelligence and P3 of the event-related potentials studied with a 3-stimulus auditory oddball task

    NARCIS (Netherlands)

    Wronka, E.A.; Kaiser, J.; Coenen, A.M.L.

    2013-01-01

    Relationship between psychometric intelligence measured with Raven's Advanced Progressive Matrices (RAPM) and event-related potentials (ERP) was examined using 3-stimulus oddball task. Subjects who had scored higher on RAPM exhibited larger amplitude of P3a component. Additional analysis using the

  19. Aerobic Fitness and Cognitive Development: Event-Related Brain Potential and Task Performance Indices of Executive Control in Preadolescent Children

    Science.gov (United States)

    Hillman, Charles H.; Buck, Sarah M.; Themanson, Jason R.; Pontifex, Matthew B.; Castelli, Darla M.

    2009-01-01

    The relationship between aerobic fitness and executive control was assessed in 38 higher- and lower-fit children (M[subscript age] = 9.4 years), grouped according to their performance on a field test of aerobic capacity. Participants performed a flanker task requiring variable amounts of executive control while event-related brain potential…

  20. An event-related brain potential study of visual selective attention to conjunctions of color and shape

    NARCIS (Netherlands)

    Smid, HGOM; Jakob, A; Heinze, HJ

    What cognitive processes underlie event-related brain potential (ERP) effects related to visual multidimensional selective attention and how are these processes organized? We recorded ERPs when participants attended to one conjunction of color, global shape and local shape and ignored other