WorldWideScience

Sample records for event-related single-shot volumetric

  1. Single-Shot, Volumetrically Illuminated, Three-Dimensional, Tomographic Laser-Induced-Fluorescence Imaging in a Gaseous Free Jet

    Science.gov (United States)

    2016-04-28

    Single- shot , volumetrically illuminated, three- dimensional, tomographic laser-induced- fluorescence imaging in a gaseous free jet Benjamin R. Halls...37081 Göttingen, Germany 4School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA 5trmeyer@purdue.edu 6james.gord...us.af.mil Abstract: Single- shot , tomographic imaging of the three-dimensional concentration field is demonstrated in a turbulent gaseous free jet in co-flow

  2. The single-shot opto-digitizer

    International Nuclear Information System (INIS)

    Nail, M.; Gibert, Ph.

    2000-01-01

    Laser-plasma experiments need to measure signals provided either by X-ray, photonic or neutronic detector. The measurement should have 50 GHz bandwidth and up to several hundred of Giga-Hertz for sub picosecond plasmas. For this purpose, a 35 GHz single shot opto-digitizer (10 ps risetime) has been studied and built. The device is made up of a 50 ohms microstrip propagation line, periodically lined by 100 sampled gates. The propagation line is long enough to measure a 400 ps duration. The sampling rate is 250 Gsa/s (every 4 ps). The sampled gates are made with fast recombining photo-material and turn on by a subpicosecond laser pulse which is synchronized exactly with the analysed phenomena. Every gate is recording to a storing capacitor. After the recording, every capacitor charge is needed to built the signal that was displayed on the propagation line. The dynamic range of measurement is 47 for the entire device. The device can measure positive or negative signals from 1.5 to 70 Volts. To increase the bandwidth, two another kinds of opto-digitizer were studied: one is a buried stripline with 56 GHz band width, the other a 70 GHz coplanar transmission line. For the purpose of subpicosecond plasmas, a 30 coplanar waveguide opto-digitizer was studied. Characteristics are as followed: window of measurement 40 ps, sampling rate 1 ps, bandwidth 230 GHz. Finally, a bundle of optical fibers was used to propagate the laser beam on semiconductor gates. If the gates are lighted at the same time, i.e. if the optical fibers have the same length, we get a simultaneous addressing. By using different lengths of optical fibers, we can do a sequential addressing. So, the sampling rate becomes a combination of the distance between two adjacent sampled channels, and the difference in length of optical fibers. (author)

  3. Volumetric Combustion Diagnostics

    Science.gov (United States)

    2017-01-03

    Force Office of Scientific Research Submitted by: Lin Ma, PhD Professor Department of Aerospace and Ocean Engineering Department of Mechanical ...established PLIF (planar LIF [11, 12]) to volumetric measurement of species concentration, and have demonstrated single- shot VLIF measurements in both...Ikeda, J., Xu, W., Carter, C.D. Single Shot 3D Flame Diagnostic Based on Volumetric Laser Induced Fluorescence (VLIF), Proceedings of the

  4. Single-shot 35 fs temporal resolution electron shadowgraphy

    Energy Technology Data Exchange (ETDEWEB)

    Scoby, C. M.; Li, R. K.; Threlkeld, E.; To, H.; Musumeci, P. [Department of Physics and Astronomy, UCLA, Los Angeles, California 90095 (United States)

    2013-01-14

    We obtain single-shot time-resolved shadowgraph images of the electromagnetic fields resulting from the interaction of a high intensity ultrashort laser pulse with a metal surface. Using a high brightness relativistic electron beam and a high streaking speed radiofrequency deflector, we report <35 fs temporal resolution enabling a direct visualization of the retarded-time dominated field evolution which follows the laser-induced charge emission. A model including the finite signal propagation speed well reproduces the data and yields measurements of fundamental parameters in short pulse laser-matter interaction such as the amount of emitted charge and the emission time scale.

  5. Improved focal liver lesion detection: comparison of single-shot diffusion-weighted echoplanar and single-shot T-2 weighted turbo spin echo techniques

    NARCIS (Netherlands)

    Coenegrachts, K.; Delanote, J.; ter Beek, L.; Haspeslagh, M.; Bipat, S.; Stoker, J.; van Kerkhove, F.; Steyaert, L.; Rigauts, H.; Casselman, J. W.

    2007-01-01

    The purpose of this study was to compare diffusion-weighted respiratory-triggered single-shot spin echo echoplanar imaging (SS SE-EPI) sequence using four b-values (b=0, b=20, b=300, b=800 s mm(-2)) and single-shot T-2 weighted turbo spin echo (T2W SS TSE) in patients with focal liver lesions, with

  6. Single-shot work extraction in quantum thermodynamics revisited

    Science.gov (United States)

    Wang, Shang-Yung

    2018-01-01

    We revisit the problem of work extraction from a system in contact with a heat bath to a work storage system, and the reverse problem of state formation from a thermal system state in single-shot quantum thermodynamics. A physically intuitive and mathematically simple approach using only elementary majorization theory and matrix analysis is developed, and a graphical interpretation of the maximum extractable work, minimum work cost of formation, and corresponding single-shot free energies is presented. This approach provides a bridge between two previous methods based respectively on the concept of thermomajorization and a comparison of subspace dimensions. In addition, a conceptual inconsistency with regard to general work extraction involving transitions between multiple energy levels of the work storage system is clarified and resolved. It is shown that an additional contribution to the maximum extractable work in those general cases should be interpreted not as work extracted from the system, but as heat transferred from the heat bath. Indeed, the additional contribution is an artifact of a work storage system (essentially a suspended ‘weight’ that can be raised or lowered) that does not truly distinguish work from heat. The result calls into question the common concept that a work storage system in quantum thermodynamics is simply the quantum version of a suspended weight in classical thermodynamics.

  7. Single-shot polarimetry imaging of multicore fiber.

    Science.gov (United States)

    Sivankutty, Siddharth; Andresen, Esben Ravn; Bouwmans, Géraud; Brown, Thomas G; Alonso, Miguel A; Rigneault, Hervé

    2016-05-01

    We report an experimental test of single-shot polarimetry applied to the problem of real-time monitoring of the output polarization states in each core within a multicore fiber bundle. The technique uses a stress-engineered optical element, together with an analyzer, and provides a point spread function whose shape unambiguously reveals the polarization state of a point source. We implement this technique to monitor, simultaneously and in real time, the output polarization states of up to 180 single-mode fiber cores in both conventional and polarization-maintaining fiber bundles. We demonstrate also that the technique can be used to fully characterize the polarization properties of each individual fiber core, including eigen-polarization states, phase delay, and diattenuation.

  8. Time-resolved single-shot terahertz time-domain spectroscopy for ultrafast irreversible processes

    Science.gov (United States)

    Zhai, Zhao-Hui; Zhong, Sen-Cheng; Li, Jun; Zhu, Li-Guo; Meng, Kun; Li, Jiang; Liu, Qiao; Peng, Qi-Xian; Li, Ze-Ren; Zhao, Jian-Heng

    2016-09-01

    Pulsed terahertz spectroscopy is suitable for spectroscopic diagnostics of ultrafast events. However, the study of irreversible or single shot ultrafast events requires ability to record transient properties at multiple time delays, i.e., time resolved at single shot level, which is not available currently. Here by angular multiplexing use of femtosecond laser pulses, we developed and demonstrated a time resolved, transient terahertz time domain spectroscopy technique, where burst mode THz pulses were generated and then detected in a single shot measurement manner. The burst mode THz pulses contain 2 sub-THz pulses, and the time gap between them is adjustable up to 1 ns with picosecond accuracy, thus it can be used to probe the single shot event at two different time delays. The system can detect the sub-THz pulses at 0.1 THz-2.5 THz range with signal to noise ratio (SNR) of ˜400 and spectrum resolution of 0.05 THz. System design was described here, and optimizations of single shot measurement of THz pulses were discussed in detail. Methods to improve SNR were also discussed in detail. A system application was demonstrated where pulsed THz signals at different time delays of the ultrafast process were successfully acquired within single shot measurement. This time resolved transient terahertz time domain spectroscopy technique provides a new diagnostic tool for irreversible or single shot ultrafast events where dynamic information can be extracted at terahertz range within one-shot experiment.

  9. Single-shot self-interference incoherent digital holography using off-axis configuration.

    Science.gov (United States)

    Hong, Jisoo; Kim, Myung K

    2013-12-01

    We propose a single-shot incoherent holographic imaging technique that adopts self-interference incoherent digital holography (SIDH) with slight tilt of the plane mirror in the optical configuration. The limited temporal coherence length of the illumination leads the guide-star hologram of the proposed system to have a Gaussian envelope of elliptical ring shape. The observation shows that the reconstruction by cross correlation with the guide-star hologram achieves better quality than the usual propagation methods. Experimentally, we verify that the hologram and 3D reconstruction can be implemented incoherently with the proposed single-shot off-axis SIDH.

  10. Single-shot two-dimensional full-range optical coherence tomography achieved by dispersion control

    NARCIS (Netherlands)

    Witte, S.; Baclayon, M.; Peterman, E.J.G.; Toonen, R.F.G.; Mansvelder, H.D.; Groot, M.L.

    2009-01-01

    We present a full-range Fourier-domain optical coherence tomography (OCT) system that is capable of acquiring two-dimensional images of living tissue in a single shot. By using line illumination of the sample in combination with a two-dimensional imaging spectrometer, 1040 depth scans are performed

  11. Comparative Study on the Efficacy of Two Regimens of Single-Shot ...

    African Journals Online (AJOL)

    ... mother by increasing self esteem and improving bonding with the baby. Objective: To assess and compare the satisfaction and efficacy of two regimens of single-shot spinal blocks for the relief of labor pain in women who present in active phase of labour. Design: A prospective randomised single-blind observational study

  12. A second-order autocorrelator for single-shot measurement of ...

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging) 1461 1996 Oct 15 13:05:22

    mental and second-harmonic frequency respectively, and 2α is the crossover angle of the beams inside the ... dispersion (GVD) effects in the crystal and spatial resolution of the imaging system. In the case ... Figure 3a shows the image of SH radiation from the KDP crystal corresponding to the single- shot operation of the ...

  13. Single-shot LIBS spectral quality for waste particles in open air

    NARCIS (Netherlands)

    Xia, H.; Bakker, M.C.M.

    2015-01-01

    This work investigates the ability of LIBS to produce quality spectra from small particles of concrete demolition waste using single-shot spectra collected in open air. The 2–8?mm materials are rounded river gravel, green glass shards, and plastic flakes. Considered are focal length, air, moisture,

  14. Single shot damage mechanism of Mo/Si multilayer optics under intense pulsed XUV-exposures

    NARCIS (Netherlands)

    Khorsand, A.R.; Sobierajski, R.; Louis, Eric; Bruijn, S.; Gleeson, A.; van de Kruijs, Robbert Wilhelmus Elisabeth; Gullikson, E.M.; Bijkerk, Frederik

    2010-01-01

    We investigated single shot damage of Mo/Si multilayer coatings exposed to the intense fs XUV radiation at the Free-electron LASer facility in Hamburg - FLASH. The interaction process was studied in situ by XUV reflectometry, time resolved optical microscopy, and “post-mortem” by

  15. Inversion recovery single-shot TurboFLASH for assessment of myocardial infarction at 3 Tesla.

    Science.gov (United States)

    Bauner, Kerstin U; Muehling, Olaf; Wintersperger, Bernd J; Winnik, Eva; Reiser, Maximilian F; Huber, Armin

    2007-06-01

    The aim of the study was to assess the diagnostic accuracy of imaging myocardial infarction with a single-shot inversion recovery turbofast low-angle shot (SS IR turboFLASH) sequence at 3.0 Tesla in comparison with an established segmented inversion recovery turboFLASH sequence at 1.5 Tesla. Fifteen patients with myocardial infarction were examined at a 1.5 Tesla magnetic resonance (MR) System (Avanto, Siemens, Medical Solutions) and at a 3.0 Tesla MR system (TIM Trio, Siemens, Medical Solutions). Imaging delayed enhancement was started 15 minutes after application of contrast material. A SS IR turboFLASH was performed at 3.0 Tesla and compared with a segmented IR turboFLASH sequence at 1.5 and at 3.0 Tesla. The IR turboFLASH sequence at 1.5 Tesla served as reference method. Infarct volumes, contrast/noise ratio (CNR) of infarcted and normal myocardium were compared with the reference method. The Single-Shot IR turboFLASH technique allows imaging 9 slices during a single breath-hold. The CNR between infarction and normal myocardium of the reference method was 6.4 at 1.5 Tesla. The mean value of CNR of the IR turboFLASH sequence was 7.3 at 3.0 Tesla for the single-shot technique and 14.1 at 3.0 Tesla for the segmented technique. No significant difference was found for the CNR values of the reference technique at 1.5 Tesla and the single-shot technique at 3.0 Tesla, however for the comparison of the segmented technique at 1.5 and at 3 Tesla (P = 0.0001). The correlation coefficients of the infarct volumes, determined with the Single-Shot IR turboFLASH and the segmented IR turboFLASH technique at 3.0 compared with the reference method, were r = 0.95 (P < 0.0001) and r = 0.95 (P < 0.0001). The loss of CNR, which is caused by replacement of the segmented technique by the single-shot technique, is completely compensated by the approximately 2-fold CNR increase at the higher field strength. The IR turboFLASH technique at 3.0 Tesla IR can be used as a single-shot technique

  16. MR cholangiopancreatography of pancreaticobiliary diseases: Comparison of single-shot RARE and multislice HASTE sequences

    Energy Technology Data Exchange (ETDEWEB)

    Morrin, Martina M.; Farrell, Richard J.; McEntee, Gerry; MacMathuna, Padraic; Stack, John P.; Murrah, John G

    2000-11-01

    AIMS: We prospectively compared two breath-hold magnetic resonance cholangiopancreatography (MRCP) sequences: single-shot rapid acquisition with relaxation enhancement (RARE) and multislice half-Fourier acquisition single-shot turbo spin echo (HASTE) in imaging the pancreaticobiliary system. PATIENTS AND METHODS: The diagnostic accuracy of single-shot RARE and multislice HASTE was studied in 34 subjects who had undergone conventional cholangiopancreatography. Overall image quality, duct conspicuity, image artifact, signal intensity and contrast-to-noise ratios were assessed independently by two radiologists who were unaware of the underlying diagnosis. RESULTS: Both sequences had comparable diagnostic accuracy regarding a normal biliary system, choledocholithiasis, extra-hepatic and intra-hepatic strictures. Single-shot RARE was superior to multislice HASTE in diagnosing a normal pancreatic system, pancreatic and intrahepatic duct strictures, while providing significantly better image quality (mean {+-} SE 3.7 {+-} 0.07 vs 3.3 {+-} 0.08: P = 0.02) and significantly less image artifact (mean {+-} SE 3.6 {+-} 0.07 vs 3.2 {+-} 0.08:P = 0.01). Single-shot RARE provided significantly better duct conspicuity regarding the pancreatic duct within the body (2.7 {+-} 0.2 vs 2.1 {+-} 0.2: P = 0.003) and tail (2.4 {+-} 0.2 vs 1.6 {+-} 0.2;P = 0.0001), as well as the intrahepatic ducts (3.0 {+-} 0.1 vs 2.6 {+-} 0.1: P = 0.004) but there was no significant difference regarding the remainder of the biliary tree. CONCLUSION: Single-shot RARE provides superior image quality, duct conspicuity with the added advantage of less image artifact and shorter acquisition time. However, volume averaging can cause common bile duct stones to be missed. Therefore, multislice HASTE sequences should still be acquired if choledocholithiasis is suspected. Larger studies are required to assess the diagnostic efficacy of single-shot RARE sequences in pancreatic duct and intra-hepatic duct disease

  17. Speckle noise reduction in single-shot holographic two-wavelength contouring

    Science.gov (United States)

    Agour, Mostafa; Klattenhoff, Reiner; Falldorf, Claas; Bergmann, Ralf B.

    2017-05-01

    We present an experimental configuration that enables form measurement from a single-shot camera exposure. It combines two-wavelength contouring with spatial multiplexing synthetic-aperture digital holography. The synthetic-aperture in this work is formed by simultaneously illuminating the test object from two different angles. The two illumination directions and the two-wavelength contouring result in four holograms which are spatially multiplexed on a single camera target avoiding unwanted cross-interference between them by means of coherence gating. In contrast to standard holographic contouring methods, the proposed technique reduces speckle decorrelation noise and enables single shot form measurement. To demonstrate this technique, the shape of a micro cold drawing part is determined.

  18. Algorithms for image recovery calculation in extended single-shot phase-shifting digital holography

    Science.gov (United States)

    Hasegawa, Shin-ya; Hirata, Ryo

    2018-02-01

    The single-shot phase-shifting method of image recovery using an inclined reference wave has the advantages of reducing the effects of vibration, being capable of operating in real time, and affording low-cost sensing. In this method, relatively low reference angles compared with that in the conventional method using phase shift between three or four pixels has been required. We propose an extended single-shot phase-shifting technique which uses the multiple-step phase-shifting algorithm and the corresponding multiple pixels which are the same as that of the period of an interference fringe. We have verified the theory underlying this recovery method by means of Fourier spectral analysis and its effectiveness by evaluating the visibility of the image using a high-resolution pattern. Finally, we have demonstrated high-contrast image recovery experimentally using a resolution chart. This method can be used in a variety of applications such as color holographic interferometry.

  19. Algorithms for image recovery calculation in extended single-shot phase-shifting digital holography

    Science.gov (United States)

    Hasegawa, Shin-ya; Hirata, Ryo

    2018-04-01

    The single-shot phase-shifting method of image recovery using an inclined reference wave has the advantages of reducing the effects of vibration, being capable of operating in real time, and affording low-cost sensing. In this method, relatively low reference angles compared with that in the conventional method using phase shift between three or four pixels has been required. We propose an extended single-shot phase-shifting technique which uses the multiple-step phase-shifting algorithm and the corresponding multiple pixels which are the same as that of the period of an interference fringe. We have verified the theory underlying this recovery method by means of Fourier spectral analysis and its effectiveness by evaluating the visibility of the image using a high-resolution pattern. Finally, we have demonstrated high-contrast image recovery experimentally using a resolution chart. This method can be used in a variety of applications such as color holographic interferometry.

  20. Single-shot observation of growing streamers using an ultrafast camera

    International Nuclear Information System (INIS)

    Takahashi, E; Kato, S; Furutani, H; Sasaki, A; Kishimoto, Y; Takada, K; Matsumura, S; Sasaki, H

    2011-01-01

    A recently developed ultrafast camera that can acquire 10 8 frames per second was used to investigate positive streamer discharge. It enabled single-shot evaluation of streamer evolution without the need to consider shot-to-shot reproducibility. This camera was used to investigate streamers in argon. Growing branches, the transition when a streamer forms a return stroke, and related phenomena were clearly observed. (fast track communication)

  1. Infrared single shot diagnostics for the longitudinal profile of the electron bunches at FLASH

    International Nuclear Information System (INIS)

    Delsim-Hashemi, Hossein

    2008-09-01

    The longitudinal profile of electron bunches plays an important role in the design of single-pass free electron lasers and future linear e + e - colliders. For the free electron laser FLASH in Hamburg, a longitudinal compression scheme is used which results in an asymmetric longitudinal bunch profile with a 'spike'. This 'spike', which has a very high peak current, is used in a high-gain SASE-FEL process to produce high intensity (about 70 μJ) femtosecond photon pulses in the XUV wavelength range. The required high peak current of the electron bunch is realized by confining a large number of electrons in a width, measured in time units, of few tens of femtosecond, making the diagnostics of such bunches a challenge. Furthermore, the operation of facilities such as FLASH shows that single-shot diagnostics is indispensable. It is intuitive to use a time domain method to measure the electron bunch length. However, when the structures present in the bunch profile fall in the femtoseconds range, this is beyond the resolution of time-resolved methods developed so far. In this thesis, a wavelength-domain technique is described that can fulfill both requirements of single shot and high resolution reaching to the femtoseconds range. The amount of charge that is confined in a typical length of several femtoseconds (FWHM of the spike) can be determined by a novel single-shot spectrometer that resolves the coherent radiation (e.g. coherent transition radiation) in the far-infrared and mid-infrared range. Furthermore the extension of this single-shot spectroscopy to shorter wavelengths reaching the near-infrared, makes it possible to investigate the presence of structures in the bunch profile that might correlate or anti-correlate to the SASE intensity. (orig.)

  2. Infrared single shot diagnostics for the longitudinal profile of the electron bunches at FLASH

    Energy Technology Data Exchange (ETDEWEB)

    Delsim-Hashemi, Hossein

    2008-09-15

    The longitudinal profile of electron bunches plays an important role in the design of single-pass free electron lasers and future linear e{sup +}e{sup -} colliders. For the free electron laser FLASH in Hamburg, a longitudinal compression scheme is used which results in an asymmetric longitudinal bunch profile with a 'spike'. This 'spike', which has a very high peak current, is used in a high-gain SASE-FEL process to produce high intensity (about 70 {mu}J) femtosecond photon pulses in the XUV wavelength range. The required high peak current of the electron bunch is realized by confining a large number of electrons in a width, measured in time units, of few tens of femtosecond, making the diagnostics of such bunches a challenge. Furthermore, the operation of facilities such as FLASH shows that single-shot diagnostics is indispensable. It is intuitive to use a time domain method to measure the electron bunch length. However, when the structures present in the bunch profile fall in the femtoseconds range, this is beyond the resolution of time-resolved methods developed so far. In this thesis, a wavelength-domain technique is described that can fulfill both requirements of single shot and high resolution reaching to the femtoseconds range. The amount of charge that is confined in a typical length of several femtoseconds (FWHM of the spike) can be determined by a novel single-shot spectrometer that resolves the coherent radiation (e.g. coherent transition radiation) in the far-infrared and mid-infrared range. Furthermore the extension of this single-shot spectroscopy to shorter wavelengths reaching the near-infrared, makes it possible to investigate the presence of structures in the bunch profile that might correlate or anti-correlate to the SASE intensity. (orig.)

  3. Single-Shot Readout of a Superconducting Qubit using a Josephson Parametric Oscillator

    Science.gov (United States)

    2016-01-11

    Single-shot Readout of a Superconducting Qubit using a Josephson Parametric Oscillator Philip Kranz1, Andreas Bengtsson1, Michaël Simoen1, Simon...Josephson Parametric Oscillator Philip Krantz1, Andreas Bengtsson1, Michaël Simoen1, Simon Gustavsson2, Vitaly Shumeiko1, W. D. Oliver2,3, C. M...2016) We propose and demonstrate a new read-out technique for a superconducting qubit by dispersively coupling it to a Josephson parametric

  4. Reliability Assessment of a Single-Shot System by Use of Screen Test Results

    Science.gov (United States)

    2018-02-01

    unlimited. NUWC Keyport #17-002. Reliability Assessment of a Single-Shot System by Use of Screen Test Results Abstract: Field reliability prediction...approach described here assumes that the defect density during testing takes the form of an exponential decay, although other mathematical functions can...be substituted for the exponential. In order to apply the decay rate function to a discrete pass/fail test scheme, the approach provides for

  5. Single shot diffraction of picosecond 8.7-keV x-ray pulses

    Directory of Open Access Journals (Sweden)

    F. H. O’Shea

    2012-02-01

    Full Text Available We demonstrate multiphoton, single shot diffraction images of x rays produced by inverse Compton scattering a high-power CO_{2} laser from a relativistic electron beam, creating a pulse of 8.7 keV x rays. The tightly focused, relatively high peak brightness electron beam and high photon density from the 2 J CO_{2} laser yielded 6×10^{7} x-ray photons over the full opening angle in a single shot. Single shot x-ray diffraction is performed by passing the x rays though a vertical slit and on to a flat silicon (111 crystal. 10^{2} diffracted photons were detected. The spectrum of the detected x rays is compared to simulation. The diffraction and detection of 10^{2} x rays is a key step to a more efficient time resolved diagnostic in which the number of observed x rays might reach 10^{4}; enabling a unique, flexible x-ray source as a sub-ps resolution diagnostic for studying the evolution of chemical reactions, lattice deformation and melting, and magnetism.

  6. Single-shot echo-planar imaging of multiple sclerosis: effects of varying echo time

    International Nuclear Information System (INIS)

    Wolansky, L.J.; Chong, S.; Liu, W.C.; Kang, E.; Simpson, S.W.; Karimi, S.; Akbari, H.

    1999-01-01

    Our aim was to determine the relative merits of short and long echo times (TE) with single-shot echo-planar imaging for imaging cerebral lesions such as multiple sclerosis. We examined seven patients with clinically definite multiple sclerosis were imaged at 1.5 T. Patients were scanned with spin-echo, single-shot echo-planar imaging, using TEs of 45, 75, 105, and 135 ms. Region of interest (ROI) measurements were performed on 36 lesions at or above the level of the corona radiata. The mean image contrast (IC) was highest (231.1) for a TE of 45 ms, followed by 75 ms (218.9), 105 ms (217.9), and 135 ms (191.6). When mean contrast-to-noise ratios (C/N) were compared, the value was again highest (29.7) for TE 45 ms, followed by 75 ms (28.9), 105 ms (28.5), and 135 ms (26.3). In a lesion-by-lesion comparison, TE 45 ms had the highest IC and C/N in the largest number of cases (50 % and 47.2 %, respectively). IC and C/N for TE 45 ms were superior to those of 75 ms in 64 % and 58 %, respectively. These results support the use of relatively short TEs for single-shot echo-planar imaging in the setting of cerebral lesions such as multiple sclerosis. (orig.) (orig.)

  7. Anti-botulism single-shot vaccine using chitosan for protein encapsulation by simple coacervation.

    Science.gov (United States)

    Sari, Roger S; de Almeida, Anna Christina; Cangussu, Alex S R; Jorge, Edson V; Mozzer, Otto D; Santos, Hércules Otacílio; Quintilio, Wagner; Brandi, Igor Viana; Andrade, Viviane Aguiar; Miguel, Angelo Samir M; Sobrinho Santos, Eliane M

    2016-12-01

    The aim of the present study was to compare the potency and safety of vaccines against Clostridium botulinum (C. botulinum) type C and D formulated with chitosan as controlled release matrix and vaccines formulated in conventional manner using aluminum hydroxide. Parameters were established for the development of chitosan microspheres, using simple coacervation to standardize the use of this polymer in protein encapsulation for vaccine formulation. To formulate a single shot vaccine inactivated antigens of C. botulinum type C and D were used with original toxin titles equal to 5.2 and 6.2 log LD50/ml, respectively. For each antigen a chitosan based solution of 50 mL was prepared. Control vaccines were formulated by mixing toxoid type C and D with aluminum hydroxide [25% Al(OH) 3 , pH 6.3]. The toxoid sterility, innocuity and potency of vaccines were evaluated as stipulated by MAPA-BRASIL according to ministerial directive no. 23. Encapsulation efficiency of BSA in chitosan was 32.5-40.37%, while that the encapsulation efficiency to toxoid type C was 41,03% (1.94 mg/mL) and of the toxoid type D was 32.30% (1.82 mg/mL). The single shot vaccine formulated using chitosan for protein encapsulation through simple coacervation showed potency and safety similar to conventional vaccine currently used in Brazilian livestock (10 and 2 IU/mL against C. botulinum type C and D, respectively). The present work suggests that our single shot vaccine would be a good option as a cattle vaccine against these C. botulinum type C and D. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Partial Fourier techniques in single-shot cross-term spatiotemporal encoded MRI.

    Science.gov (United States)

    Zhang, Zhiyong; Frydman, Lucio

    2018-03-01

    Cross-term spatiotemporal encoding (xSPEN) is a single-shot approach with exceptional immunity to field heterogeneities, the images of which faithfully deliver 2D spatial distributions without requiring a priori information or using postacquisition corrections. xSPEN, however, suffers from signal-to-noise ratio penalties due to its non-Fourier nature and due to diffusion losses-especially when seeking high resolution. This study explores partial Fourier transform approaches that, acting along either the readout or the spatiotemporally encoded dimensions, reduce these penalties. xSPEN uses an orthogonal (e.g., z) gradient to read, in direct space, the low-bandwidth (e.g., y) dimension. This substantially changes the nature of partial Fourier acquisitions vis-à-vis conventional imaging counterparts. A suitable theoretical analysis is derived to implement these procedures, along either the spatiotemporally or readout axes. Partial Fourier single-shot xSPEN images were recorded on preclinical and human scanners. Owing to their reduction in the experiments' acquisition times, this approach provided substantial sensitivity gains vis-à-vis previous implementations for a given targeted in-plane resolution. The physical origins of these gains are explained. Partial Fourier approaches, particularly when implemented along the low-bandwidth spatiotemporal dimension, provide several-fold sensitivity advantages at minimal costs to the execution and processing of the single-shot experiments. Magn Reson Med 79:1506-1514, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  9. Single-shot secure quantum network coding on butterfly network with free public communication

    Science.gov (United States)

    Owari, Masaki; Kato, Go; Hayashi, Masahito

    2018-01-01

    Quantum network coding on the butterfly network has been studied as a typical example of quantum multiple cast network. We propose a secure quantum network code for the butterfly network with free public classical communication in the multiple unicast setting under restricted eavesdropper’s power. This protocol certainly transmits quantum states when there is no attack. We also show the secrecy with shared randomness as additional resource when the eavesdropper wiretaps one of the channels in the butterfly network and also derives the information sending through public classical communication. Our protocol does not require verification process, which ensures single-shot security.

  10. Deconvolution single shot multibox detector for supermarket commodity detection and classification

    Science.gov (United States)

    Li, Dejian; Li, Jian; Nie, Binling; Sun, Shouqian

    2017-07-01

    This paper proposes an image detection model to detect and classify supermarkets shelves' commodity. Based on the principle of the features directly affects the accuracy of the final classification, feature maps are performed to combine high level features with bottom level features. Then set some fixed anchors on those feature maps, finally the label and the position of commodity is generated by doing a box regression and classification. In this work, we proposed a model named Deconvolutiuon Single Shot MultiBox Detector, we evaluated the model using 300 images photographed from real supermarket shelves. Followed the same protocol in other recent methods, the results showed that our model outperformed other baseline methods.

  11. Single-shot femtosecond-pulsed phase-shifting digital holography.

    Science.gov (United States)

    Kakue, Takashi; Itoh, Seiya; Xia, Peng; Tahara, Tatsuki; Awatsuji, Yasuhiro; Nishio, Kenzo; Ura, Shogo; Kubota, Toshihiro; Matoba, Osamu

    2012-08-27

    Parallel phase-shifting digital holography is capable of three-dimensional measurement of a dynamically moving object with a single-shot recording. In this letter, we demonstrated a parallel phase-shifting digital holography using a single femtosecond light pulse whose central wavelength and temporal duration were 800 nm and 96 fs, respectively. As an object, we set spark discharge in atmospheric pressure air induced by applying a high voltage to between two electrodes. The instantaneous change in phase caused by the spark discharge was clearly reconstructed. The reconstructed phase image shows the change of refractive index of air was -3.7 × 10(-4).

  12. Single-shot beam profile diagnostics for x-ray FEL's using gas fluorescence

    Science.gov (United States)

    Feng, Yiping; Zhu, Diling; Weninger, Clemens; Alonso-Mori, Roberto; Chollet, Matthieu; Damiani, Daniel S.; Glownia, James M.; Hastings, Jerome B.; Nelson, Silke; Song, Sanghoon; Robert, Aymeric

    2017-06-01

    We report experimental demonstration of capturing single-shot X-ray Free-electron Laser (FEL) beam profiles using gas fluorescence. The measurement was carried out at the Linac Coherent Light Source using 7 keV hard X-rays propagating through ambient air. The nitrogen fluorescence emitted upon the passage of the X-ray FEL beam were imaged using a highly sensitive optical setup, and there was sufficient optical yield that single-shot measurements were feasible. By taking two orthogonal and simultaneous images, the beam trajectory could be determined in a nearly non-invasive manner, and is best suited for photon energies in the soft X-ray regime, where such a diagnostic capability has been largely unavailable previously. The integrated intensity of the images could also serve as a non-invasive intensity monitor, complementary to current implementations of gas- and solidbased monitors. High repetition-rate Free-electron Lasers can greatly benefit from such a new diagnostic tool for eliminating potential thermal damages.

  13. Single-shot quantitative phase microscopy with color-multiplexed differential phase contrast (cDPC.

    Directory of Open Access Journals (Sweden)

    Zachary F Phillips

    Full Text Available We present a new technique for quantitative phase and amplitude microscopy from a single color image with coded illumination. Our system consists of a commercial brightfield microscope with one hardware modification-an inexpensive 3D printed condenser insert. The method, color-multiplexed Differential Phase Contrast (cDPC, is a single-shot variant of Differential Phase Contrast (DPC, which recovers the phase of a sample from images with asymmetric illumination. We employ partially coherent illumination to achieve resolution corresponding to 2× the objective NA. Quantitative phase can then be used to synthesize DIC and phase contrast images or extract shape and density. We demonstrate amplitude and phase recovery at camera-limited frame rates (50 fps for various in vitro cell samples and c. elegans in a micro-fluidic channel.

  14. Optimization And Single-Shot Characterization Of Ultrashort Thz Pulses From A Laser Wakefield Accelerator

    International Nuclear Information System (INIS)

    Plateau, G.R.; Matlis, N.H.; van Tilborg, J.; Geddes, C.G.R.; Toth, Cs.; Schroeder, C.B.; Leemans, W.P.

    2009-01-01

    We present spatiotemporal characterization of μJ-class ultrashort THz pulses generated from a laser wakefield accelerator (LWFA). Accelerated electrons, resulting from the interaction of a high-intensity laser pulse with a plasma, emit high-intensity THz pulses as coherent transition radiation. Such high peak-power THz pulses, suitable for high-field (MV/cm) pump-probe experiments, also provide a non-invasive bunch-length diagnostic and thus feedback for the accelerator. The characterization of the THz pulses includes energy measurement using a Golay cell, 2D sign-resolved electro-optic measurement and single-shot spatiotemporal electric-field distribution retrieval using a new technique, coined temporal electric-field cross-Correlation (TEX). All three techniques corroborate THz pulses of ∼ 5 μJ, with peak fields of 100's of kV/cm and ∼ 0.4 ps rms duration.

  15. Single-Shot Quantum Nondemolition Detection of Individual Itinerant Microwave Photons

    Science.gov (United States)

    Besse, Jean-Claude; Gasparinetti, Simone; Collodo, Michele C.; Walter, Theo; Kurpiers, Philipp; Pechal, Marek; Eichler, Christopher; Wallraff, Andreas

    2018-04-01

    Single-photon detection is an essential component in many experiments in quantum optics, but it remains challenging in the microwave domain. We realize a quantum nondemolition detector for propagating microwave photons and characterize its performance using a single-photon source. To this aim, we implement a cavity-assisted conditional phase gate between the incoming photon and a superconducting artificial atom. By reading out the state of this atom in a single shot, we reach an external (internal) photon-detection fidelity of 50% (71%), limited by transmission efficiency between the source and the detector (75%) and the coherence properties of the qubit. By characterizing the coherence and average number of photons in the field reflected off the detector, we demonstrate its quantum nondemolition nature. We envisage applications in generating heralded remote entanglement between qubits and for realizing logic gates between propagating microwave photons.

  16. Fast Detection of Airports on Remote Sensing Images with Single Shot MultiBox Detector

    Science.gov (United States)

    Xia, Fei; Li, HuiZhou

    2018-01-01

    This paper introduces a method for fast airport detection on remote sensing images (RSIs) using Single Shot MultiBox Detector (SSD). To our knowledge, this could be the first study which introduces an end-to-end detection model into airport detection on RSIs. Based on the common low-level features between natural images and RSIs, a convolution neural network trained on large amounts of natural images was transferred to tackle the airport detection problem with limited annotated data. To deal with the specific characteristics of RSIs, some related parameters in the SSD, such as the scales and layers, were modified for more accurate and rapider detection. The experiments show that the proposed method could achieve 83.5% Average Recall at 8 FPS on RSIs with the size of 1024*1024. In contrast to Faster R-CNN, an improvement on AP and speed could be obtained.

  17. Single-shot parallel full range complex Fourier-domain optical coherence tomography

    International Nuclear Information System (INIS)

    Huang Bingjie; Bu Peng; Nan Nan; Wang Xiangzhao

    2011-01-01

    We present a method of parallel full range complex Fourier-domain optical coherence tomography (FDOCT) that is capable of acquiring an artifacts-free two-dimensional (2-D) cross-sectional image, i.e. a full range B-scan tomogram, by a single shot of 2-D CCD camera. This method is based on a spatial carrier technique, in which the spatial carrier-frequency is instantaneously introduced into the 2-D spectral interferogram registered in parallel FDOCT by using a grating-generated reference beam. The spatial-carrier-contained 2-D spectral interferogram is processed through Fourier transformation to obtain a complex 2-D spectral interferogram. From the 2-D complex spectral interferomgram, a full range B-scan tomogram is reconstructed. The principle of our method is confirmed by imaging an onion sample.

  18. Kinematic MRI using short TR single shot fast spin echo (SSFSE) in evaluating swallowing

    International Nuclear Information System (INIS)

    Isogai, Satoshi; Takehara, Yasuo; Isoda, Haruo; Kodaira, Nami; Masunaga, Hatsuko; Ozawa, Fukujirou; Kaneko, Masao; Nozaki, Atsushi; Kabasawa, Hiroyuki

    1999-01-01

    The utility of short TR single shot fast spin echo (SSFSE) MR imaging for evaluating swallowing was determined. Five healthy volunteers underwent kinematic MR imaging of swallowing with a 1.5 T MR scanner using the short TR (300 ms) SSFSE sequence. Twenty phases of sagittal sections were acquired within 6 sec, where the temporal resolution was 300 ms. For oral contrast medium, we used prune yogurt juice with Fe added. The image contrast of short TR SSFSE was found to be somewhere like that of T1-weighted images. In all cases, both the buccal and pharyngeal stages of swallowing were successfully depicted. The Fe-added prune yogurt juice performed as a positive contrast medium and helped determine anatomical structures in the buccal stage. Short TR (300 ms) SSFSE was useful in evaluating swallowing. The combined use of Fe-added prune yogurt juice was helpful in enhancing the surface of the oropharynx. (author)

  19. Single-shot in-line digital holography without twin image

    Science.gov (United States)

    Nomura, Takanori

    2018-01-01

    In-line digital holography is conventional but still attractive because of its simple optical setup. In general, sequential phase-shifting technique is mandatory to remove twin-image which makes the reconstructed image quality low. However, sequential phase-shifting technique requires multiple recording. Multiple recording means that it is not suitable for a dynamic phenomenon. In this paper, two kinds of a single-shot in-line digital holography without twin-image using a diffused illumination are presented. One is a generalized phase-shifting digital holography and the other is a computational removal of twin-image. The ideas and their experimental results are given to confirm the feasibility.

  20. Hyperspectral interferometry for single-shot absolute measurement of 3-D shape and displacement fields

    Directory of Open Access Journals (Sweden)

    Ruiz P. D.

    2010-06-01

    Full Text Available We propose a method that we call Hyperspectral Interferometry (HSI to resolve the 2π phase unwrapping problem in the analysis of interferograms recorded with a narrow-band light source. By using a broad-band light source and hyperspectral imaging system, a set of interferograms at different wavenumbers are recorded simultaneously on a high resolution image sensor. These are then assembled to form a three-dimensional intensity distribution. By Fourier transformation along the wavenumber axis, an absolute optical path difference is obtained for each pixel independently of the other pixels in the field of view. As a result, interferograms with spatially distinct regions are analysed as easily as continuous ones. The approach is illustrated with a HSI system to measure 3-D profiles of optically smooth or rough surfaces. Compared to existing profilometers able to measure absolute path differences, the single shot nature of the approach provides greater immunity from environmental disturbance.

  1. Single-shot read-out of a superconducting qubit using a Josephson parametric oscillator

    Science.gov (United States)

    Krantz, Philip; Bengtsson, Andreas; Simoen, Michaël; Gustavsson, Simon; Shumeiko, Vitaly; Oliver, W. D.; Wilson, C. M.; Delsing, Per; Bylander, Jonas

    2016-01-01

    We propose and demonstrate a read-out technique for a superconducting qubit by dispersively coupling it with a Josephson parametric oscillator. We employ a tunable quarter wavelength superconducting resonator and modulate its resonant frequency at twice its value with an amplitude surpassing the threshold for parametric instability. We map the qubit states onto two distinct states of classical parametric oscillation: one oscillating state, with 185±15 photons in the resonator, and one with zero oscillation amplitude. This high contrast obviates a following quantum-limited amplifier. We demonstrate proof-of-principle, single-shot read-out performance, and present an error budget indicating that this method can surpass the fidelity threshold required for quantum computing. PMID:27156732

  2. Compressive sensing sectional imaging for single-shot in-line self-interference incoherent holography

    Science.gov (United States)

    Weng, Jiawen; Clark, David C.; Kim, Myung K.

    2016-05-01

    A numerical reconstruction method based on compressive sensing (CS) for self-interference incoherent digital holography (SIDH) is proposed to achieve sectional imaging by single-shot in-line self-interference incoherent hologram. The sensing operator is built up based on the physical mechanism of SIDH according to CS theory, and a recovery algorithm is employed for image restoration. Numerical simulation and experimental studies employing LEDs as discrete point-sources and resolution targets as extended sources are performed to demonstrate the feasibility and validity of the method. The intensity distribution and the axial resolution along the propagation direction of SIDH by angular spectrum method (ASM) and by CS are discussed. The analysis result shows that compared to ASM the reconstruction by CS can improve the axial resolution of SIDH, and achieve sectional imaging. The proposed method may be useful to 3D analysis of dynamic systems.

  3. Single shot near edge x-ray absorption fine structure spectroscopy in the laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Mantouvalou, I., E-mail: ioanna.mantouvalou@tu-berlin.de; Witte, K.; Martyanov, W.; Jonas, A.; Grötzsch, D.; Kanngießer, B. [Institute for Optics and Atomic Physics, Technical University of Berlin, D-10623 Berlin (Germany); Streeck, C. [Physikalisch-Technische Bundesanstalt (PTB), D-10587 Berlin (Germany); Löchel, H.; Rudolph, I.; Erko, A. [Helmholtz-Zentrum Berlin, D-14109 Berlin (Germany); Stiel, H. [Max Born Institute for Nonlinear Optics and Short Pulse Spectroscopy, D-12489 Berlin (Germany)

    2016-05-16

    With the help of adapted off-axis reflection zone plates, near edge X-ray absorption fine structure spectra at the C and N K-absorption edge have been recorded using a single 1.2 ns long soft X-ray pulse. The transmission experiments were performed with a laser-produced plasma source in the laboratory rendering time resolved measurements feasible independent on large scale facilities. A resolving power of E/ΔE ∼ 950 at the respective edges could be demonstrated. A comparison of single shot spectra with those collected with longer measuring time proves that all features of the used reference samples (silicon nitrate and polyimide) can be resolved in 1.2 ns. Hence, investigations of radiation sensitive biological specimen become possible due to the high efficiency of the optical elements enabling low dose experiments.

  4. 3 ns single-shot read-out in a quantum dot-based memory structure

    International Nuclear Information System (INIS)

    Nowozin, T.; Bimberg, D.; Beckel, A.; Lorke, A.; Geller, M.

    2014-01-01

    Fast read-out of two to six charges per dot from the ground and first excited state in a quantum dot (QD)-based memory is demonstrated using a two-dimensional electron gas. Single-shot measurements on modulation-doped field-effect transistor structures with embedded InAs/GaAs QDs show read-out times as short as 3 ns. At low temperature (T = 4.2 K) this read-out time is still limited by the parasitics of the setup and the device structure. Faster read-out times and a larger read-out signal are expected for an improved setup and device structure

  5. Method for single-shot measurement of picosecond laser pulse-lengths without electronic time dispersion

    International Nuclear Information System (INIS)

    Kyrala, G.A.

    1987-01-01

    A two-source shear pattern recording is proposed as a method for single-shot measurement of the pulse shape from nearly monochromatic sources whose pulse lengths are shorter than their coherence times. The basis of this method relies on the assertion that if two identical electromagnetic pulses are recombined with a time delay greater than the sum of their pulse widths, the recordable spatial pattern has no fringes in it. At an arbitrary delay, translated into an actual spatial recording position, the recorded modulated intensity will sample the corresponding laser intensity at that delay time, but with a modulation due to the coherence function of the electromagnetic pulse. Two arrangements are proposed for recording the pattern. The principles, the design parameters, and the methodologies of these arrangements are presented. Resolutions of the configurations and their limitations are given as well

  6. Modelling single shot damage thresholds of multilayer optics for high-intensity short-wavelength radiation sources

    NARCIS (Netherlands)

    Loch, R.A.; Sobierajski, R.; Louis, Eric; Bosgra, J.; Bosgra, J.; Bijkerk, Frederik

    2012-01-01

    The single shot damage thresholds of multilayer optics for highintensity short-wavelength radiation sources are theoretically investigated, using a model developed on the basis of experimental data obtained at the FLASH and LCLS free electron lasers. We compare the radiation hardness of commonly

  7. Frequency-Domain Tomography for Single-shot, Ultrafast Imaging of Evolving Laser-Plasma Accelerators

    Science.gov (United States)

    Li, Zhengyan; Zgadzaj, Rafal; Wang, Xiaoming; Downer, Michael

    2011-10-01

    Intense laser pulses propagating through plasma create plasma wakefields that often evolve significantly, e.g. by expanding and contracting. However, such dynamics are known in detail only through intensive simulations. Laboratory visualization of evolving plasma wakes in the ``bubble'' regime is important for optimizing and scaling laser-plasma accelerators. Recently snap-shots of quasi-static wakes were recorded using frequency-domain holography (FDH). To visualize the wake's evolution, we have generalized FDH to frequency-domain tomography (FDT), which uses multiple probes propagating at different angles with respect to the pump pulse. Each probe records a phase streak, imprinting a partial record of the evolution of pump-created structures. We then topographically reconstruct the full evolution from all phase streaks. To prove the concept, a prototype experiment visualizing nonlinear index evolution in glass is demonstrated. Four probes propagating at 0, 0.6, 2, 14 degrees to the index ``bubble'' are angularly and temporally multiplexed to a single spectrometer to achieve cost-effective FDT. From these four phase streaks, an FDT algorithm analogous to conventional CT yields a single-shot movie of the pump's self-focusing dynamics.

  8. Single shot imaging through turbid medium and around corner using coherent light

    Science.gov (United States)

    Li, Guowei; Li, Dayan; Situ, Guohai

    2018-01-01

    Optical imaging through turbid media and around corner is a difficult challenge. Even a very thin layer of a turbid media, which randomly scatters the probe light, can appear opaque and hide any objects behind it. Despite many recent advances, no current method can image the object behind turbid media with single record using coherent laser illumination. Here we report a method that allows non-invasive single-shot optical imaging through turbid media and around corner via speckle correlation. Instead of being as an obstacle in forming diffractionlimited images, speckle actually can be a carrier that encodes sufficient information to imaging through visually opaque layers. Optical imaging through turbid media and around corner is experimentally demonstrated using traditional imaging system with the aid of iterative phase retrieval algorithm. Our method require neither scan of illumination nor two-arm interferometry or long-time exposure in acquisition, which has new implications in optical sensing through common obscurants such as fog, smoke and haze.

  9. Truly work-like work extraction via a single-shot analysis.

    Science.gov (United States)

    Aberg, Johan

    2013-01-01

    The work content of non-equilibrium systems in relation to a heat bath is often analysed in terms of expectation values of an underlying random work variable. However, when optimizing the expectation value of the extracted work, the resulting extraction process is subject to intrinsic fluctuations, uniquely determined by the Hamiltonian and the initial distribution of the system. These fluctuations can be of the same order as the expected work content per se, in which case the extracted energy is unpredictable, thus intuitively more heat-like than work-like. This raises the question of the 'truly' work-like energy that can be extracted. Here we consider an alternative that corresponds to an essentially fluctuation-free extraction. We show that this quantity can be expressed in terms of a one-shot relative entropy measure introduced in information theory. This suggests that the relations between information theory and statistical mechanics, as illustrated by concepts like Maxwell's demon, Szilard engines and Landauer's principle, extends to the single-shot regime.

  10. Efficient Background Segmentation and Seed Point Generation for a Single-Shot Stereo System

    Science.gov (United States)

    Chen, Xiaobo; Xi, Juntong

    2017-01-01

    Single-shot stereo 3D shape measurement is becoming more popular due to its advantages of noise robustness and short acquisition period. One of the key problems is stereo matching, which is related to the efficiency of background segmentation and seed point generation, etc. In this paper, a more efficient and automated matching algorithm based on digital image correlation (DIC) is proposed. The standard deviation of image gradients and an adaptive threshold are employed to segment the background. Scale-invariant feature transform (SIFT)-based feature matching and two-dimensional triangulation are combined to estimate accurate initial parameters for seed point generation. The efficiency of background segmentation and seed point generation, as well as the measuring precision, are evaluated by experimental simulation and real tests. Experimental results show that the average segmentation time for an image with a resolution of 1280 × 960 pixels is 240 milliseconds. The efficiency of seed point generation is verified to be high with different convergence criteria. PMID:29194415

  11. Single-shot readout of multiple nuclear spin qubits in diamond under ambient conditions

    Science.gov (United States)

    Jacques, Vincent

    2013-03-01

    Nuclear spins are attractive candidates for solid-state quantum information storage and processing owing to their extremely long coherence time. However, since this appealing property results from a high level of isolation from the environment, it remains a challenging task to polarize, manipulate and readout with high fidelity individual nuclear spins. A promising approach to overcome this limitation consists in utilizing an ancillary single electronic spin to detect and control remote nuclear spins coupled by hyperfine interaction. In this talk, I will show how the electronic spin of a single Nitrogen-Vacancy (NV) defect in diamond can be used as a robust platform to observe the real-time evolution of surrounding single nuclear spins under ambient conditions. Using a diamond sample with a natural abundance of 13C isotopes, we first demonstrate high fidelity initialization and single-shot readout of an individual 13C nuclear spin. By including the intrinsic 14N nuclear spin of the NV defect in the quantum register, we then report the simultaneous observation of quantum jumps linked to both nuclear spin species, providing an efficient initialization of the two qubits. These results open up new avenues for diamond-based quantum information processing (QIP) including active feedback in quantum error correction protocols and tests of quantum correlations with solid-state single spins at room temperature.

  12. Single shot, double differential spectral measurements of inverse Compton scattering in the nonlinear regime

    Directory of Open Access Journals (Sweden)

    Y. Sakai

    2017-06-01

    Full Text Available Inverse Compton scattering (ICS is a unique mechanism for producing fast pulses—picosecond and below—of bright photons, ranging from x to γ rays. These nominally narrow spectral bandwidth electromagnetic radiation pulses are efficiently produced in the interaction between intense, well-focused electron and laser beams. The spectral characteristics of such sources are affected by many experimental parameters, with intense laser effects often dominant. A laser field capable of inducing relativistic oscillatory motion may give rise to harmonic generation and, importantly for the present work, nonlinear redshifting, both of which dilute the spectral brightness of the radiation. As the applications enabled by this source often depend sensitively on its spectra, it is critical to resolve the details of the wavelength and angular distribution obtained from ICS collisions. With this motivation, we present an experimental study that greatly improves on previous spectral measurement methods based on x-ray K-edge filters, by implementing a multilayer bent-crystal x-ray spectrometer. In tandem with a collimating slit, this method reveals a projection of the double differential angular-wavelength spectrum of the ICS radiation in a single shot. The measurements enabled by this diagnostic illustrate the combined off-axis and nonlinear-field-induced redshifting in the ICS emission process. The spectra obtained illustrate in detail the strength of the normalized laser vector potential, and provide a nondestructive measure of the temporal and spatial electron-laser beam overlap.

  13. Single shot three-dimensional pulse sequence for hyperpolarized13C MRI.

    Science.gov (United States)

    Wang, Jiazheng; Wright, Alan J; Hu, De-En; Hesketh, Richard; Brindle, Kevin M

    2017-02-01

    Metabolic imaging with hyperpolarized 13 C-labeled cell substrates is a promising technique for imaging tissue metabolism in vivo. However, the transient nature of the hyperpolarization, and its depletion following excitation, limits the imaging time and the number of excitation pulses that can be used. We describe here a single-shot three-dimensional (3D) imaging sequence and demonstrate its capability to generate 13 C MR images in tumor-bearing mice injected with hyperpolarized [1- 13 C]pyruvate. The pulse sequence acquires a stack-of-spirals at two spin echoes after a single excitation pulse and encodes the kz-dimension in an interleaved manner to enhance robustness to B 0 inhomogeneity. Spectral-spatial pulses are used to acquire dynamic 3D images from selected hyperpolarized 13 C-labeled metabolites. A nominal spatial/temporal resolution of 1.25 × 1.25 × 2.5 mm 3  × 2 s was achieved in tumor images of hyperpolarized [1- 13 C]pyruvate and [1- 13 C]lactate acquired in vivo. Higher resolution in the z-direction, with a different k-space trajectory, was demonstrated in measurements on a thermally polarized [1- 13 C]lactate phantom. The pulse sequence is capable of imaging hyperpolarized 13 C-labeled substrates at relatively high spatial and temporal resolutions and is robust to moderate system imperfections. Magn Reson Med 77:740-752, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

  14. Analysis and enhancement of 3D shape accuracy in a single-shot LIDAR sensor

    Science.gov (United States)

    Han, Munhyun; Choi, Gudong; Song, Minhyup; Seo, Hongseok; Mheen, Bongki

    2017-02-01

    The accuracy of timing jitter is of prime importance in the prevalent utilization of Light Detection and Ranging (LiDAR) technology for the real-time high-resolution three-dimensional (3D) image sensor, especially for relatively small object detection in various applications, such as in the fully automated car navigation and military surveillance. To assess the accuracy of timing, that is, the accuracy of the distance or three-dimensional shape, the standard deviation method can be used in the Time-of-Flight (ToF) LiDAR technology. While most timing jitter analyses are mainly based on a fiber-network or open space at a relatively short range distance, more accurate analyses are required to extract more information about the timing jitter at in a 3D image sensor long-range free space conditions for extended LiDAR-related applications. In this paper, utilizing a Single-Shot LiDAR System (SSLs) model with a 400 MHz wideband InGaAs Avalanche Photodiode and a 1550 nm 2 nsec full width at half maximum MOPA fiber laser, we analyzed the precise timing jitter for the implemented SSLs to characterize the measurement results. Additionally, we report the enhanced results for the resolution and precision in the given SSLs using the spline interpolation method from the measured results, and multiple-shot averaging (MSA). Finally, by adapting the proposed method to an implemented high resolution 3D LiDAR prototype, called the STUD LiDAR prototype, which can be understood as one kind of SSLs because it has a single source and a single detector as in a SSLs, we observed and analyzed the 3D resolution enhancement.

  15. The single-shot opto-digitizer; L'optoechantillonneur monocoup

    Energy Technology Data Exchange (ETDEWEB)

    Nail, M.; Gibert, Ph. [CEA/DAM-Ile de France, Dept. de Conception et Realisation des Experimentations (DCRE), 91 - Bruyeres-le-Chatel (France); CEA/DAM-Ile de France, Dept. Laser Puissance, DLP, 91 - Bruyeres-Le-Chatel (France)

    2000-07-01

    Laser-plasma experiments need to measure signals provided either by X-ray, photonic or neutronic detector. The measurement should have 50 GHz bandwidth and up to several hundred of Giga-Hertz for sub picosecond plasmas. For this purpose, a 35 GHz single shot opto-digitizer (10 ps risetime) has been studied and built. The device is made up of a 50 ohms microstrip propagation line, periodically lined by 100 sampled gates. The propagation line is long enough to measure a 400 ps duration. The sampling rate is 250 Gsa/s (every 4 ps). The sampled gates are made with fast recombining photo-material and turn on by a subpicosecond laser pulse which is synchronized exactly with the analysed phenomena. Every gate is recording to a storing capacitor. After the recording, every capacitor charge is needed to built the signal that was displayed on the propagation line. The dynamic range of measurement is 47 for the entire device. The device can measure positive or negative signals from 1.5 to 70 Volts. To increase the bandwidth, two another kinds of opto-digitizer were studied: one is a buried stripline with 56 GHz band width, the other a 70 GHz coplanar transmission line. For the purpose of subpicosecond plasmas, a 30 coplanar waveguide opto-digitizer was studied. Characteristics are as followed: window of measurement 40 ps, sampling rate 1 ps, bandwidth 230 GHz. Finally, a bundle of optical fibers was used to propagate the laser beam on semiconductor gates. If the gates are lighted at the same time, i.e. if the optical fibers have the same length, we get a simultaneous addressing. By using different lengths of optical fibers, we can do a sequential addressing. So, the sampling rate becomes a combination of the distance between two adjacent sampled channels, and the difference in length of optical fibers. (author)

  16. Self-Calibrating Wave-Encoded Variable-Density Single-Shot Fast Spin Echo Imaging.

    Science.gov (United States)

    Chen, Feiyu; Taviani, Valentina; Tamir, Jonathan I; Cheng, Joseph Y; Zhang, Tao; Song, Qiong; Hargreaves, Brian A; Pauly, John M; Vasanawala, Shreyas S

    2018-04-01

    It is highly desirable in clinical abdominal MR scans to accelerate single-shot fast spin echo (SSFSE) imaging and reduce blurring due to T 2 decay and partial-Fourier acquisition. To develop and investigate the clinical feasibility of wave-encoded variable-density SSFSE imaging for improved image quality and scan time reduction. Prospective controlled clinical trial. With Institutional Review Board approval and informed consent, the proposed method was assessed on 20 consecutive adult patients (10 male, 10 female, range, 24-84 years). A wave-encoded variable-density SSFSE sequence was developed for clinical 3.0T abdominal scans to enable high acceleration (3.5×) with full-Fourier acquisitions by: 1) introducing wave encoding with self-refocusing gradient waveforms to improve acquisition efficiency; 2) developing self-calibrated estimation of wave-encoding point-spread function and coil sensitivity to improve motion robustness; and 3) incorporating a parallel imaging and compressed sensing reconstruction to reconstruct highly accelerated datasets. Image quality was compared pairwise with standard Cartesian acquisition independently and blindly by two radiologists on a scale from -2 to 2 for noise, contrast, confidence, sharpness, and artifacts. The average ratio of scan time between these two approaches was also compared. A Wilcoxon signed-rank tests with a P value under 0.05 considered statistically significant. Wave-encoded variable-density SSFSE significantly reduced the perceived noise level and improved the sharpness of the abdominal wall and the kidneys compared with standard acquisition (mean scores 0.8, 1.2, and 0.8, respectively, P variable-density sampling SSFSE achieves improved image quality with clinically relevant echo time and reduced scan time, thus providing a fast and robust approach for clinical SSFSE imaging. 1 Technical Efficacy: Stage 6 J. Magn. Reson. Imaging 2018;47:954-966. © 2017 International Society for Magnetic Resonance in Medicine.

  17. Reference-free unwarping of single-shot spatiotemporally encoded MRI using asymmetric self-refocused echoes acquisition

    Science.gov (United States)

    Chen, Ying; Chen, Song; Zhong, Jianhui; Chen, Zhong

    2015-05-01

    This paper presents a phase evolution rewinding algorithm for correcting the geometric and intensity distortions in single-shot spatiotemporally encoded (SPEN) MRI with acquisition of asymmetric self-refocused echo trains. Using the field map calculated from the phase distribution of the source image, the off-resonance induced phase errors are successfully rewound through deconvolution. The alias-free partial Fourier transform reconstruction helps improve the signal-to-noise ratio of the field maps and the output images. The effectiveness of the proposed algorithm was validated through 7 T MRI experiments on a lemon, a water phantom, and in vivo rat head. SPEN imaging was evaluated using rapid acquisition by sequential excitation and refocusing (RASER) which produces uniform T2 weighting. The results indicate that the new technique can more robustly deal with the cases in which the images obtained with conventional single-shot spin-echo EPI are difficult to be restored due to serious field variations.

  18. Single-shot photonic time-stretch digitizer using a dissipative soliton-based passively mode-locked fiber laser.

    Science.gov (United States)

    Peng, Di; Zhang, Zhiyao; Zeng, Zhen; Zhang, Lingjie; Lyu, Yanjia; Liu, Yong; Xie, Kang

    2018-03-19

    We demonstrate a single-shot photonic time-stretch digitizer using a dissipative soliton-based passively mode-locked fiber laser. The theoretical analysis and simulation results indicate that the dissipative soliton-based optical source with a flat spectrum relieves the envelope-induced signal distortion, and its high energy spectral density helps to improve the signal-to-noise ratio, both of which are favorable for simplifying the optical front-end architecture of a photonic time-stretch digitizer. By employing a homemade dissipative soliton-based passively mode-locked erbium-doped fiber laser in a single-shot photonic time-stretch digitizer, an effective number of bits of 4.11 bits under an effective sampling rate of 100 GS/s is experimentally obtained without optical amplification in the link and pulse envelope removing process.

  19. Multishot versus single-shot pulse sequences in very high field fMRI: a comparison using retinotopic mapping.

    Directory of Open Access Journals (Sweden)

    Jascha D Swisher

    Full Text Available High-resolution functional MRI is a leading application for very high field (7 Tesla human MR imaging. Though higher field strengths promise improvements in signal-to-noise ratios (SNR and BOLD contrast relative to fMRI at 3 Tesla, these benefits may be partially offset by accompanying increases in geometric distortion and other off-resonance effects. Such effects may be especially pronounced with the single-shot EPI pulse sequences typically used for fMRI at standard field strengths. As an alternative, one might consider multishot pulse sequences, which may lead to somewhat lower temporal SNR than standard EPI, but which are also often substantially less susceptible to off-resonance effects. Here we consider retinotopic mapping of human visual cortex as a practical test case by which to compare examples of these sequence types for high-resolution fMRI at 7 Tesla. We performed polar angle retinotopic mapping at each of 3 isotropic resolutions (2.0, 1.7, and 1.1 mm using both accelerated single-shot 2D EPI and accelerated multishot 3D gradient-echo pulse sequences. We found that single-shot EPI indeed led to greater temporal SNR and contrast-to-noise ratios (CNR than the multishot sequences. However, additional distortion correction in postprocessing was required in order to fully realize these advantages, particularly at higher resolutions. The retinotopic maps produced by both sequence types were qualitatively comparable, and showed equivalent test/retest reliability. Thus, when surface-based analyses are planned, or in other circumstances where geometric distortion is of particular concern, multishot pulse sequences could provide a viable alternative to single-shot EPI.

  20. Single-shot readout of a superconducting flux qubit with a flux-driven Josephson parametric amplifier

    Science.gov (United States)

    Lin, Z. R.; Inomata, K.; Oliver, W. D.; Koshino, K.; Nakamura, Y.; Tsai, J. S.; Yamamoto, T.

    2013-09-01

    We report single-shot readout of a superconducting flux qubit by using a flux-driven Josephson parametric amplifier (JPA). After optimizing the readout power, gain of the JPA, and timing of the data acquisition, we observe the Rabi oscillations with a contrast of 74%, which is mainly limited by the bandwidth of the JPA and the energy relaxation of the qubit. The observation of quantum jumps between the qubit eigenstates under continuous monitoring indicates the nondestructiveness of the readout scheme.

  1. Clinical evaluation of single-shot and readout-segmented diffusion-weighted imaging in stroke patients at 3 T

    International Nuclear Information System (INIS)

    Morelli, John; Porter, David; Ai, Fei

    2013-01-01

    Background: Diffusion-weighted imaging (DWI) magnetic resonance imaging (MRI) is most commonly performed utilizing a single-shot echo-planar imaging technique (ss-EPI). Susceptibility artifact and image blur are severe when this sequence is utilized at 3 T. Purpose: To evaluate a readout-segmented approach to DWI MR in comparison with single-shot echo planar imaging for brain MRI. Material and Methods: Eleven healthy volunteers and 14 patients with acute and early subacute infarctions underwent DWI MR examinations at 1.5 and 3T with ss-EPI and readout-segmented echo-planar (rs-EPI) DWI at equal nominal spatial resolutions. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) calculations were made, and two blinded readers ranked the scans in terms of high signal intensity bulk susceptibility artifact, spatial distortions, image blur, overall preference, and motion artifact. Results: SNR and CNR were greatest with rs-EPI (8.1 ± 0.2 SNR vs. 6.0 ± 0.2; P -4 at 3T). Spatial distortions were greater with single-shot (0.23 ± 0.03 at 3T; P <0.001) than with rs-EPI (0.12 ± 0.02 at 3T). Combined with blur and artifact reduction, this resulted in a qualitative preference for the readout-segmented scans overall. Conclusion: Substantial image quality improvements are possible with readout-segmented vs. single-shot EPI - the current clinical standard for DWI - regardless of field strength (1.5 or 3 T). This results in improved image quality secondary to greater real spatial resolution and reduced artifacts from susceptibility in MR imaging of the brain

  2. Single-shot echo-planar MR sequences in the diagnosis of intracranial infectious diseases

    International Nuclear Information System (INIS)

    Tsuchiya, Kazuhiro; Katase, Shichiro; Yoshino, Ayako; Yamakami, Norio; Hachiya, Junichi

    1998-01-01

    The purpose of this study was to present our preliminary experience in the application of echo-planar-imaging (EPI) MR sequences for the diagnosis of intracranial infectious diseases and to assess the value of these sequences. We reviewed single-shot EPI MR images obtained at 1.5 T in 17 patients and compared these images with conventional or fast spin-echo (SE) or fluid attenuated inversion-recovery (FLAIR) images. The clinical diagnoses for the 17 patients were meningitis (2 patients), encephalitis or meningoencephalitis (7 patients), brain abscess (5 patients), epidural empyema (2 patients) and Creutzfeldt-Jakob disease (1 patient). We obtained EPI-T 2 -weighted (T 2 W) images in 8 patients, EPI-FLAIR images in 13 patients and EPI-diffusion-weighted (DW) images in 14 patients. Among the 8 patients for whom EPI-T 2 W imaging was performed, EPI-T 2 W imaging yielded superior results compared with SE-T 2 W imaging in 3 patients as a consequence of patient motion and equal results compared with SE-T 2 W imaging in 5 patients. Among the 13 patients for whom EPI-FLAIR imaging was performed, the EPI-FLAIR images were superior to conventional FLAIR images in 3 unstable patients. In the remaining 10 patients for whom EPI-FLAIR imaging was performed, EPI-FLAIR images were equivalent or inferior to conventional FLAIR images. In 6 patients with encephalitis or meningoencephalitis, the encephalitic lesions showed hyperintensity in EPI-DW images to a greater extent than in images obtained with the other techniques. In 3 patients, EPI-DW images also demonstrated hyperintensity for the contents of abscesses or areas of empyema that was not seen with the other imaging techniques. The value of EPI-T 2 W and EPI-FLAIR imaging is limited in uncooperative patients. EPI-DW imaging was found to be of value for the evaluation of several intracranial infectious diseases. (author)

  3. Single-shot echo-planar MR sequences in the diagnosis of intracranial infectious diseases

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, Kazuhiro; Katase, Shichiro; Yoshino, Ayako; Yamakami, Norio; Hachiya, Junichi [Kyorin Univ., Mitaka, Tokyo (Japan). School of Medicine

    1998-06-01

    The purpose of this study was to present our preliminary experience in the application of echo-planar-imaging (EPI) MR sequences for the diagnosis of intracranial infectious diseases and to assess the value of these sequences. We reviewed single-shot EPI MR images obtained at 1.5 T in 17 patients and compared these images with conventional or fast spin-echo (SE) or fluid attenuated inversion-recovery (FLAIR) images. The clinical diagnoses for the 17 patients were meningitis (2 patients), encephalitis or meningoencephalitis (7 patients), brain abscess (5 patients), epidural empyema (2 patients) and Creutzfeldt-Jakob disease (1 patient). We obtained EPI-T{sub 2}-weighted (T{sub 2}W) images in 8 patients, EPI-FLAIR images in 13 patients and EPI-diffusion-weighted (DW) images in 14 patients. Among the 8 patients for whom EPI-T{sub 2}W imaging was performed, EPI-T{sub 2}W imaging yielded superior results compared with SE-T{sub 2}W imaging in 3 patients as a consequence of patient motion and equal results compared with SE-T{sub 2}W imaging in 5 patients. Among the 13 patients for whom EPI-FLAIR imaging was performed, the EPI-FLAIR images were superior to conventional FLAIR images in 3 unstable patients. In the remaining 10 patients for whom EPI-FLAIR imaging was performed, EPI-FLAIR images were equivalent or inferior to conventional FLAIR images. In 6 patients with encephalitis or meningoencephalitis, the encephalitic lesions showed hyperintensity in EPI-DW images to a greater extent than in images obtained with the other techniques. In 3 patients, EPI-DW images also demonstrated hyperintensity for the contents of abscesses or areas of empyema that was not seen with the other imaging techniques. The value of EPI-T{sub 2}W and EPI-FLAIR imaging is limited in uncooperative patients. EPI-DW imaging was found to be of value for the evaluation of several intracranial infectious diseases. (author)

  4. Pharmaceutical and immunological evaluation of a single-shot hepatitis B vaccine formulated with PLGA microspheres.

    Science.gov (United States)

    Shi, Li; Caulfield, Michael J; Chern, Rey T; Wilson, Roger A; Sanyal, Gautam; Volkin, David B

    2002-04-01

    A single-shot Hepatitis B vaccine formulation using poly(d,l)-lactide-co-glycolide acid (PLGA) microspheres as a delivery system was examined using a variety of biophysical and biochemical techniques as well as immunological evaluation in C3H mice. PLGA microsphere encapsulation of the Hepatitis B surface antigen (HBsAg), a lipoprotein particle, resulted in good recoveries of protein mass, protein particle conformational integrity, and in vitro antigenicity. Some partial delipidation of the HBsAg, however, was observed. The loading and encapsulation efficiency of HBsAg into the PLGA microspheres were measured along with the morphology and size distribution of the vaccine-loaded PLGA microspheres. The in vitro release kinetics of HBsAg from the PLGA microspheres was evaluated and found to be affected by experimental conditions such as stirring rate. HBsAg showed enhanced storage stability at 37 degrees C in the slightly acidic pH range reported to be found inside PLGA microspheres; thus, the antigen is relatively stable under conditions of temperature and pH that may mimic in vivo conditions. The immunogenicity of the microsphere formulations of HBsAg was compared with conventional aluminum adjuvant formulated HBsAg vaccine in C3H mice. Comparisons were made between aluminum formulations (one and two injections), PLGA microsphere formulations (single injection), and a mixture of aluminum and PLGA microsphere formulations (single injection). The nine-month serum antibody titers indicate that a single injection of a mixture of aluminum and PLGA-formulated HBsAg results in equal or better immune responses than two injections of aluminum-formulated HBsAg vaccine. Based on these in vitro and in vivo studies, it is concluded that HBsAg can be successfully encapsulated and recovered from the PLGA microspheres and a mixture of aluminum-adjuvanted and PLGA-formulated HBsAg can auto-boost an immune response in manner comparable to multiple injections of an aluminum

  5. A single-shot nonlinear autocorrelation approach for time-resolved physics in the vacuum ultraviolet spectral range

    International Nuclear Information System (INIS)

    Rompotis, Dimitrios

    2016-02-01

    In this work, a single-shot temporal metrology scheme operating in the vacuum-extreme ultraviolet spectral range has been designed and experimentally implemented. Utilizing an anti-collinear geometry, a second-order intensity autocorrelation measurement of a vacuum ultraviolet pulse can be performed by encoding temporal delay information on the beam propagation coordinate. An ion-imaging time-of-flight spectrometer, offering micrometer resolution has been set-up for this purpose. This instrument enables the detection of a magnified image of the spatial distribution of ions exclusively generated by direct two-photon absorption in the combined counter-propagating pulse focus and thus obtain the second-order intensity autocorrelation measurement on a single-shot basis. Additionally, an intense VUV light source based on high-harmonic generation has been experimentally realized. It delivers intense sub-20 fs Ti:Sa fifth-harmonic pulses utilizing a loose-focusing geometry in a long Ar gas cell. The VUV pulses centered at 161.8 nm reach pulse energies of 1.1 μJ per pulse, while the corresponding pulse duration is measured with a second-order, fringe-resolved autocorrelation scheme to be 18 ± 1 fs on average. Non-resonant, two-photon ionization of Kr and Xe and three-photon ionization of Ne verify the fifth-harmonic pulse intensity and indicate the feasibility of multi-photon VUV pump/VUV probe studies of ultrafast atomic and molecular dynamics. Finally, the extended functionally of the counter-propagating pulse metrology approach is demonstrated by a single-shot VUV pump/VUV probe experiment aiming at the investigation of ultrafast dissociation dynamics of O 2 excited in the Schumann-Runge continuum at 162 nm.

  6. Supplemental single shot femoral nerve block for total hip arthroplasty: impact on early postoperative care, pain management and lung function.

    Science.gov (United States)

    Wiesmann, T; Steinfeldt, T; Wagner, G; Wulf, H; Schmitt, J; Zoremba, M

    2014-01-01

    Peripheral regional anesthesia is beneficial in the management of postoperative pain in hip surgery, and can also reduce post-operative care unit (PACU) stay. Its opioid-sparing actions may also be beneficial for respiratory mechanics and pulmonary function. The aim of our pilot study was to evaluate the effect of a supplemental single shot femoral block for elective total hip arthroplasty on early respiratory function and postoperative management within the first 24 postoperative hours. We prospectively studied 80 patients undergoing total hip arthroplasty. Written informed consent was obtained after ethics committee approval. Forty patients were randomLy assigned to receive single shot femoral nerve block (FNB) using 15mL bupivacaine 0.25% and 20 mg clonidine while the remainder received standard treatment without nerve block (STN). Premedication and general anesthesia were standardized. Pulse oximetry saturation and spirometric lung function were measured preoperatively (baseline) and at 0.5 h, 2 h, 6 h and 24 h, after extubation breathing room air. PACU surveillance and postoperative pain therapy was standardized. Oxygen saturation and spirometry results were significantly better within the FNB group during the first six postoperative hours. Although VAS scores during the PACU stay did not significantly differ between the study groups, PACU discharge criteria were met earlier in the FNB group (116±40 min [mean±SD] vs. 152±47 min in the STN group). The FNB group exhibited significantly lower VAS scores at 6 and 24 hours. Supplemental single shot femoral nerve block for total hip arthroplasty resulted in earlier PACU discharge capability, improved lung function during the first six hours and better pain control within the first 24 postoperative hours.

  7. X-Ray Emission Spectrometer Design with Single-Shot Pump-Probe and Resonant Excitation Capabilities

    Energy Technology Data Exchange (ETDEWEB)

    Spoth, Katherine; /SUNY, Buffalo /SLAC

    2012-08-28

    Core-level spectroscopy in the soft X-ray regime is a powerful tool for the study of chemical bonding processes. The ultrafast, ultrabright X-ray pulses generated by the Linac Coherent Light Source (LCLS) allow these reactions to be studied in greater detail than ever before. In this study, we investigated a conceptual design of a spectrometer for the LCLS with imaging in the non-dispersive direction. This would allow single-shot collection of X-ray emission spectroscopy (XES) measurements with varying laser pump X-ray probe delay or a variation of incoming X-ray energy over the illuminated area of the sample. Ray-tracing simulations were used to demonstrate how the components of the spectrometer affect its performance, allowing a determination of the optimal final design. These simulations showed that the spectrometer's non-dispersive focusing is extremely sensitive to the size of the sample footprint; the spectrometer is not able to image a footprint width larger than one millimeter with the required resolution. This is compatible with a single shot scheme that maps out the laser pump X-ray probe delay in the non-dispersive direction as well as resonant XES applications at normal incidence. However, the current capabilities of the Soft X-Ray (SXR) beamline at the LCLS do not produce the required energy range in a small enough sample footprint, hindering the single shot resonant XES application at SXR for chemical dynamics studies at surfaces. If an upgraded or future beamline at LCLS is developed with lower monochromator energy dispersion the width can be made small enough at the required energy range to be imaged by this spectrometer design.

  8. Femtosecond Single-Shot Imaging of Nanoscale Ferromagnetic Order in Co/Pd Multilayers using Resonant X-ray Holography

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Tianhan; Zhu, Diling; Benny Wu,; Graves, Catherine; Schaffert, Stefan; Rander, Torbjorn; Muller, leonard; Vodungbo, Boris; Baumier, Cedric; Bernstein, David P.; Brauer, Bjorn; Cros, Vincent; Jong, Sanne de; Delaunay, Renaud; Fognini, Andreas; Kukreja, Roopali; Lee, Sooheyong; Lopez-Flores, Victor; Mohanty, Jyoti; Pfau, Bastian; Popescu, 5 Horia

    2012-05-15

    We present the first single-shot images of ferromagnetic, nanoscale spin order taken with femtosecond x-ray pulses. X-ray-induced electron and spin dynamics can be outrun with pulses shorter than 80 fs in the investigated fluence regime, and no permanent aftereffects in the samples are observed below a fluence of 25 mJ/cm{sup 2}. Employing resonant spatially-muliplexed x-ray holography results in a low imaging threshold of 5 mJ/cm{sup 2}. Our results open new ways to combine ultrafast laser spectroscopy with sequential snapshot imaging on a single sample, generating a movie of excited state dynamics.

  9. Observation of Quantum Jumps of a Single Quantum Dot Spin Using Submicrosecond Single-Shot Optical Readout

    Science.gov (United States)

    Delteil, Aymeric; Gao, Wei-bo; Fallahi, Parisa; Miguel-Sanchez, Javier; Imamoǧlu, Atac

    2014-03-01

    Single-shot readout of individual qubits is typically the slowest process among the elementary single- and two-qubit operations required for quantum information processing. Here, we use resonance fluorescence from a single-electron charged quantum dot to read out the spin-qubit state in 800 nanoseconds with a fidelity exceeding 80%. Observation of the spin evolution on longer time scales reveals quantum jumps of the spin state: we use the experimentally determined waiting-time distribution to characterize the quantum jumps.

  10. Single shot fringe pattern phase demodulation using Hilbert-Huang transform aided by the principal component analysis.

    Science.gov (United States)

    Trusiak, Maciej; Służewski, Łukasz; Patorski, Krzysztof

    2016-02-22

    Hybrid single shot algorithm for accurate phase demodulation of complex fringe patterns is proposed. It employs empirical mode decomposition based adaptive fringe pattern enhancement (i.e., denoising, background removal and amplitude normalization) and subsequent boosted phase demodulation using 2D Hilbert spiral transform aided by the Principal Component Analysis method for novel, correct and accurate local fringe direction map calculation. Robustness to fringe pattern significant noise, uneven background and amplitude modulation as well as local fringe period and shape variations is corroborated by numerical simulations and experiments. Proposed automatic, adaptive, fast and comprehensive fringe analysis solution compares favorably with other previously reported techniques.

  11. Simultaneous single-shot readout of multi-qubit circuits using a traveling-wave parametric amplifier

    Science.gov (United States)

    O'Brien, Kevin

    Observing and controlling the state of ever larger quantum systems is critical for advancing quantum computation. Utilizing a Josephson traveling wave parametric amplifier (JTWPA), we demonstrate simultaneous multiplexed single shot readout of 10 transmon qubits in a planar architecture. We employ digital image sideband rejection to eliminate noise at the image frequencies. We quantify crosstalk and infidelity due to simultaneous readout and control of multiple qubits. Based on current amplifier technology, this approach can scale to simultaneous readout of at least 20 qubits. This work was supported by the Army Research Office.

  12. Real time quantitative phase microscopy based on single-shot transport of intensity equation (ssTIE) method

    Science.gov (United States)

    Yu, Wei; Tian, Xiaolin; He, Xiaoliang; Song, Xiaojun; Xue, Liang; Liu, Cheng; Wang, Shouyu

    2016-08-01

    Microscopy based on transport of intensity equation provides quantitative phase distributions which opens another perspective for cellular observations. However, it requires multi-focal image capturing while mechanical and electrical scanning limits its real time capacity in sample detections. Here, in order to break through this restriction, real time quantitative phase microscopy based on single-shot transport of the intensity equation method is proposed. A programmed phase mask is designed to realize simultaneous multi-focal image recording without any scanning; thus, phase distributions can be quantitatively retrieved in real time. It is believed the proposed method can be potentially applied in various biological and medical applications, especially for live cell imaging.

  13. Development and Characterization of Two-Dimensional Gratings for Single-Shot X-ray Phase-Contrast Imaging

    Directory of Open Access Journals (Sweden)

    Margarita Zakharova

    2018-03-01

    Full Text Available Single-shot grating-based phase-contrast imaging techniques offer additional contrast modalities based on the refraction and scattering of X-rays in a robust and versatile configuration. The utilization of a single optical element is possible in such methods, allowing the shortening of the acquisition time and increasing flux efficiency. One of the ways to upgrade single-shot imaging techniques is to utilize customized optical components, such as two-dimensional (2D X-ray gratings. In this contribution, we present the achievements in the development of 2D gratings with UV lithography and gold electroplating. Absorption gratings represented by periodic free-standing gold pillars with lateral structure sizes from 5 µm to 25 µm and heights from 5 µm to 28 µm have shown a high degree of periodicity and defect-free patterns. Grating performance was tested in a radiographic setup using a self-developed quality assessment algorithm based on the intensity distribution histograms. The algorithm allows the final user to estimate the suitability of a specific grating to be used in a particular setup.

  14. Optimization of laser energy deposition for single-shot high aspect-ratio microstructuring of thick BK7 glass

    Energy Technology Data Exchange (ETDEWEB)

    Garzillo, Valerio; Grigutis, Robertas [Dipartimento di Scienza e Alta Tecnologia, University of Insubria, Via Valleggio 11, I-22100 Como (Italy); Jukna, Vytautas [Centre de Physique Theorique, CNRS, Ecole Polytechnique, Université Paris-Saclay, F-91128 Palaiseau (France); LOA, ENSTA-ParisTech, CNRS, Ecole Polytechnique, Université Paris Saclay, F-91762 Palaiseau (France); Couairon, Arnaud [Centre de Physique Theorique, CNRS, Ecole Polytechnique, Université Paris-Saclay, F-91128 Palaiseau (France); Di Trapani, Paolo [Dipartimento di Scienza e Alta Tecnologia, University of Insubria and CNISM UdR Como, Via Valleggio 11, I-22100 Como (Italy); Jedrkiewicz, Ottavia, E-mail: ottavia.jedrkiewicz@ifn.cnr.it [Istituto di Fotonica e Nanotecnologie, CNR and CNISM UdR Como, Via Valleggio 11, I-22100 Como (Italy)

    2016-07-07

    We investigate the generation of high aspect ratio microstructures across 0.7 mm thick glass by means of single shot Bessel beam laser direct writing. We study the effect on the photoinscription of the cone angle, as well as of the energy and duration of the ultrashort laser pulse. The aim of the study is to optimize the parameters for the writing of a regular microstructure due to index modification along the whole sample thickness. By using a spectrally resolved single pulse transmission diagnostics at the output surface of the glass, we correlate the single shot material modification with observations of the absorption in different portions of the retrieved spectra, and with the absence or presence of spectral modulation. Numerical simulations of the evolution of the Bessel pulse intensity and of the energy deposition inside the sample help us interpret the experimental results that suggest to use picosecond pulses for an efficient and more regular energy deposition. Picosecond pulses take advantage of nonlinear plasma absorption and avoid temporal dynamics effects which can compromise the stationarity of the Bessel beam propagation.

  15. Generating multiple contrasts using single-shot radial T1 sensitive and insensitive steady-state imaging.

    Science.gov (United States)

    Benkert, Thomas; Bartsch, Andreas J; Blaimer, Martin; Jakob, Peter M; Breuer, Felix A

    2015-06-01

    Recently, the (Resolution Enhanced-) T1 insensitive steady-state imaging (TOSSI) approach has been proposed for the fast acquisition of T2 -weighted images. This has been achieved by balanced steady-state free precession (bSSFP) imaging between unequally spaced inversion pulses. The purpose of this work is to present an extension of this technique, considerably increasing both the efficiency and possibilities of TOSSI. A radial trajectory in combination with an appropriate view-sharing reconstruction is used. Because each projection traverses the contrast defining k-space center, several different contrasts can be extracted from a single-shot measurement. These contrasts include various T2 -weightings and T2 /T1 -weighting if an even number of inversion pulses is used, while an odd number allow the generation of several images with predefined tissue types cancelled. The approach is validated for brain and abdominal imaging at 3.0 Tesla. Results are compared with RE-TOSSI, bSSFP, and turbo spin-echo images and are shown to provide similar contrasts in a fraction of scan time. Furthermore, the potential utility of the approach is illustrated by images obtained from a brain tumor patient. Radial T1 sensitive and insensitive steady-state imaging is able to generate multiple contrasts out of one single-shot measurement in a short scan time. © 2014 Wiley Periodicals, Inc.

  16. Single-shot mega-electronvolt ultrafast electron diffraction for structure dynamic studies of warm dense matter

    Energy Technology Data Exchange (ETDEWEB)

    Mo, M. Z., E-mail: mmo09@slac.stanford.edu; Shen, X.; Chen, Z.; Li, R. K.; Dunning, M.; Zheng, Q.; Weathersby, S. P.; Reid, A. H.; Coffee, R.; Makasyuk, I.; Edstrom, S.; McCormick, D.; Jobe, K.; Hast, C.; Glenzer, S. H.; Wang, X. [SLAC National Accelerator Laboratory, 2575 Sand Hill Road, Menlo Park, California 94025 (United States); Sokolowski-Tinten, K. [Faculty of Physics and Centre for Nanointegration Duisburg-Essen, University of Duisburg-Essen, Lotharstrasse 1, D-47048 Duisburg (Germany)

    2016-11-15

    We have developed a single-shot mega-electronvolt ultrafast-electron-diffraction system to measure the structural dynamics of warm dense matter. The electron probe in this system is featured by a kinetic energy of 3.2 MeV and a total charge of 20 fC, with the FWHM pulse duration and spot size at sample of 350 fs and 120 μm respectively. We demonstrate its unique capability by visualizing the atomic structural changes of warm dense gold formed from a laser-excited 35-nm freestanding single-crystal gold foil. The temporal evolution of the Bragg peak intensity and of the liquid signal during solid-liquid phase transition are quantitatively determined. This experimental capability opens up an exciting opportunity to unravel the atomic dynamics of structural phase transitions in warm dense matter regime.

  17. Single-shot spectro-temporal characterization of XUV pulses from a seeded free-electron laser

    Science.gov (United States)

    de Ninno, Giovanni; Gauthier, David; Mahieu, Benoît; Ribič, Primož Rebernik; Allaria, Enrico; Cinquegrana, Paolo; Danailov, Miltcho Bojanov; Demidovich, Alexander; Ferrari, Eugenio; Giannessi, Luca; Penco, Giuseppe; Sigalotti, Paolo; Stupar, Matija

    2015-08-01

    Intense ultrashort X-ray pulses produced by modern free-electron lasers (FELs) allow one to probe biological systems, inorganic materials and molecular reaction dynamics with nanoscale spatial and femtoscale temporal resolution. These experiments require the knowledge, and possibly the control, of the spectro-temporal content of individual pulses. FELs relying on seeding have the potential to produce spatially and temporally fully coherent pulses. Here we propose and implement an interferometric method, which allows us to carry out the first complete single-shot spectro-temporal characterization of the pulses, generated by an FEL in the extreme ultraviolet spectral range. Moreover, we provide the first direct evidence of the temporal coherence of a seeded FEL working in the extreme ultraviolet spectral range and show the way to control the light generation process to produce Fourier-limited pulses. Experiments are carried out at the FERMI FEL in Trieste.

  18. Measurement of the single-shot pulse energy of a free electron laser using a cryogenic radiometer

    Energy Technology Data Exchange (ETDEWEB)

    Masahiro, Kato; Norio, Saito; Yuichiro, Morishita; Takahiro, Tanaka [National Institute of Advanced Industrial Science and Technology (AIST), NMIJ, Tsukuba (Japan); Masahiro, Kato; Norio, Saito; Kai, Tiedtke; Pavle N, Juranic; Sorokin, A.A.; Richter, M.; Takahiro, Tanaka; Mitsuru, Nagasono; Makina, Yabashi; Kensuke, Tono; Tadashi, Togashi; Tetsuya, Ishikawa [RIKEN, XFEL Project Head Office, Kouto, Sayo, Hyogo (Japan); Kai, Tiedtke; Pavle N, Juranic; Sorokin, A.A.; Jastrow, U. [Deutsches Elektronen-Synchrotron, DESY, Hamburg (Germany); Sorokin, A.A. [Ioffe Physico-Technical Institute, Polytekhnicheskaya 26, St Petersburg (Russian Federation); Richter, M.; Kroth, U.; Schoppe, H. [Physikalisch-Technische Bundesanstalt, PTB, Berlin (Germany); Tadashi, Togashi; Hiroaki, Kimura; Haruhiko, Ohashi [Japan Synchrotron Radiation Research Institute, Sayo, Hyogo (Japan)

    2010-10-15

    The absolute single-shot pulse energy of the SPring 8 extreme ultraviolet (EUV) free electron laser (FEL) was measured using a cryogenic radiometer with a relative standard uncertainty of 3%. The temperature change of the cavity in the cryogenic radiometer caused by an incident FEL pulse was determined using a lock-in amplifier and an ac Wheatstone bridge. The measured pulse energies were compared with a gas-monitor detector developed by Physikalisch-Technische Bundesanstalt/Deutsches Elektronen-Synchrotron/Ioffe Physico-Technical Institute (Ioffe) at a wavelength of 51.3 nm at the SPring-8 EUV-FEL in a shot-to-shot mode. The pulse energies measured using the two detectors agree within 2.0%. (authors)

  19. Characterization of temporal coherence of hard X-ray free-electron laser pulses with single-shot interferograms

    Directory of Open Access Journals (Sweden)

    Taito Osaka

    2017-11-01

    Full Text Available Temporal coherence is one of the most fundamental characteristics of light, connecting to spectral information through the Fourier transform relationship between time and frequency. Interferometers with a variable path-length difference (PLD between the two branches have widely been employed to characterize temporal coherence properties for broad spectral regimes. Hard X-ray interferometers reported previously, however, have strict limitations in their operational photon energies, due to the specific optical layouts utilized to satisfy the stringent requirement for extreme stability of the PLD at sub-ångström scales. The work presented here characterizes the temporal coherence of hard X-ray free-electron laser (XFEL pulses by capturing single-shot interferograms. Since the stability requirement is drastically relieved with this approach, it was possible to build a versatile hard X-ray interferometer composed of six separate optical elements to cover a wide photon energy range from 6.5 to 11.5 keV while providing a large variable delay time of up to 47 ps at 10 keV. A high visibility of up to 0.55 was observed at a photon energy of 10 keV. The visibility measurement as a function of time delay reveals a mean coherence time of 5.9 ± 0.7 fs, which agrees with that expected from the single-shot spectral information. This is the first result of characterizing the temporal coherence of XFEL pulses in the hard X-ray regime and is an important milestone towards ultra-high energy resolutions at micro-electronvolt levels in time-domain X-ray spectroscopy, which will open up new opportunities for revealing dynamic properties in diverse systems on timescales from femtoseconds to nanoseconds, associated with fluctuations from ångström to nanometre spatial scales.

  20. Diffusion-weighted single shot echo planar imaging of colorectal cancer using a sensitivity-encoding technique

    International Nuclear Information System (INIS)

    Nasu, Katsuhiro; Kuroki, Yoshihumi; Murakami, Koji; Nawano, Shigeru; Kuroki, Seiko; Moriyama, Noriyuki

    2004-01-01

    We wanted to determine the feasibility of diffusion-weighted single shot echo planar imaging using a sensitivity encoding diffusion weighted imaging (SENSE-DWI) technique in depicting colorectal cancer. Forty-two patients with sigmoid colon cancer and rectal cancer, all proven pathologically, were examined on T2-turbo spin echo (TSE) and SENSE-DWI. No bowel preparation was performed before examination. The b-factors used in SENSE-DWI were zero and 1000 s/mm 2 . In 10 randomly selected cases, the images whose b-factors were 250 and 500 s/mm 2 were also obtained. The reduction factor of SENSE was 2.0 in all sequences. Two radiologists evaluated the obtained images from the viewpoints of tumor detectability, image distortion and misregistration of the tumors. The apparent diffusion coefficients (ADCs) of the tumors and urine in the urinary bladders in each patient were measured to evaluate the correlation between ADC and pathological classification of each tumor. All tumors were depicted hyperintensely on SENSE-DWI. Even though single shot echo planar imaging (EPI) was used, the image distortion and misregistration was quite pronounced because of simultaneous use of SENSE. On SENSE-DWI whose b-factor was 1000 s/mm 2 , the normal colon wall and feces were always hypointense and easily differentiated from the tumors. The mean ADC value of each tumor was 1.02±0.1 (x 10 -3 ) mm 2 /s. No overt correlation can be pointed out between ADC and pathological classification of each tumor. SENSE-DWI is a feasible method for depicting colorectal cancer. SENSE-DWI provides strong contrast among colorectal cancers, normal rectal wall and feces. (authors)

  1. Clinical application of Half Fourier Acquisition Single Shot Turbo Spin Echo (HASTE) imaging accelerated by simultaneous multi-slice acquisition.

    Science.gov (United States)

    Schulz, Jenni; P Marques, José; Ter Telgte, Annemieke; van Dorst, Anouk; de Leeuw, Frank-Erik; Meijer, Frederick J A; Norris, David G

    2018-01-01

    As a single-shot sequence with a long train of refocusing pulses, Half-Fourier Acquisition Single-Shot Turbo-Spin-Echo (HASTE) suffers from high power deposition limiting use at high resolutions and high field strengths, particularly if combined with acceleration techniques such as simultaneous multi-slice (SMS) imaging. Using a combination of multiband (MB)-excitation and PINS-refocusing pulses will effectively accelerate the acquisition time while staying within the SAR limitations. In particular, uncooperative and young patients will profit from the speed of the MB-PINS HASTE sequence, as clinical diagnosis can be possible without sedation. Materials and MethodsMB-excitation and PINS-refocusing pulses were incorporated into a HASTE-sequence with blipped CAIPIRINHA and TRAPS including an internal FLASH reference scan for online reconstruction. Whole brain MB-PINS HASTE data were acquired on a Siemens 3T-Prisma system from 10 individuals and compared to a clinical HASTE protocol. ResultsThe proposed MB-PINS HASTE protocol accelerates the acquisition by about a factor 2 compared to the clinical HASTE. The diagnostic image quality proved to be comparable for both sequences for the evaluation of the overall aspect of the brain, the detection of white matter changes and areas of tissue loss, and for the evaluation of the CSF spaces although artifacts were more frequently encountered with MB-PINS HASTE. ConclusionsMB-PINS HASTE enables acquisition of slice accelerated highly T2-weighted images and provides good diagnostic image quality while reducing acquisition time. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Blood Bupivacaine Concentrations After a Combined Single-Shot Sciatic Block and a Continuous Femoral Nerve Block in Pediatric Patients: A Prospective Observational Study.

    Science.gov (United States)

    Suresh, Santhanam; De Oliveira, Gildasio S

    2017-05-01

    We evaluated blood bupivacaine concentrations in children having a single-shot sciatic and continuous femoral blocks after anterior cruciate ligament repair. Dried blood spot samples were analyzed for bupivacaine levels at 0, 5, 15, 30, 60, and 120 minutes and 4, 24, and 48 hours. The highest 99% upper confidence interval limit was 135 ng/mL at the 4-hour evaluation point. The 99% upper confidence interval was below potentially toxic levels (1500 ng/mL) across all sampling times. The risk of local anesthetic toxicity in pediatric patients receiving single-shot sciatic and continuous femoral nerve blocks is very low.

  3. Diffusion-weighted imaging of the sellar region: A comparison study of BLADE and single-shot echo planar imaging sequences

    Energy Technology Data Exchange (ETDEWEB)

    Yiping, Lu [Department of Radiology, Huashan Hospital, Fudan University, 12 Wulumuqi Rd. Middle, Shanghai 200040 (China); Hui, Liu [MR Collaboration NE Asia, Siemens Healthcare, Siemens Ltd., China, Shanghai 201318 (China); Kun, Zhou [MR PLM APPL, Siemens Shenzhen Magnetic Resonance Ltd., Shenzhen 518057 (China); Daoying, Geng, E-mail: GengdaoyingGDY@163.com [Department of Radiology, Huashan Hospital, Fudan University, 12 Wulumuqi Rd. Middle, Shanghai 200040 (China); Bo, Yin, E-mail: yinbo7@163.com [Department of Radiology, Huashan Hospital, Fudan University, 12 Wulumuqi Rd. Middle, Shanghai 200040 (China)

    2014-07-15

    Purpose: The purpose of this study is to compare BLADE diffusion-weighted imaging (DWI) with single-shot echo planar imaging (EPI) DWI on the aspects of feasibility of imaging the sellar region and image quality. Methods: A total of 3 healthy volunteers and 52 patients with suspected lesions in the sellar region were included in this prospective intra-individual study. All exams were performed at 3.0 T with a BLADE DWI sequence and a standard single-shot EP-DWI sequence. Phantom measurements were performed to measure the objective signal-to-noise ratio (SNR). Two radiologists rated the image quality according to the visualisation of the internal carotid arteries, optic chiasm, pituitary stalk, pituitary gland and lesion, and the overall image quality. One radiologist measured lesion sizes for detecting their relationship with the image score. Results: The SNR in BLADE DWI sequence showed no significant difference from the single-shot EPI sequence (P > 0.05). All of the assessed regions received higher scores in BLADE DWI images than single-shot EP-DWI.

  4. Ankle Block vs Single-Shot Popliteal Fossa Block as Primary Anesthesia for Forefoot Operative Procedures: Prospective, Randomized Comparison.

    Science.gov (United States)

    Schipper, Oliver N; Hunt, Kenneth J; Anderson, Robert B; Davis, W Hodges; Jones, Carroll P; Cohen, Bruce E

    2017-11-01

    Postoperative pain is often difficult to control with oral medications, requiring large doses of opioid analgesia. Regional anesthesia may be used for primary anesthesia, reducing the need for general anesthetic and postoperative pain medication requirements in the immediate postoperative period. The purpose of this study was to compare the analgesic effects of an ankle block (AB) to a single-shot popliteal fossa block (PFB) for patients undergoing orthopedic forefoot procedures. All patients having elective outpatient orthopedic forefoot procedures were invited to participate in the study. Patients were prospectively randomized to receive either an ultrasound-guided AB or PFB by a board-certified anesthesiologist prior to their procedure. Intraoperative conversion to general anesthesia and postanesthesia care unit (PACU) opioid requirements were recorded. Postoperative pain was assessed using the visual analog scale (VAS) at regular time intervals until 8 am on postoperative day (POD) 2. Patients rated the effectiveness of the block on a 1 to 5 scale, with 5 being very effective. A total of 167 patients participated in the study with 88 patients (53%) receiving an AB and 79 (47%) receiving a single-shot PFB. There was no significant difference in the rate of conversion to general anesthesia between the 2 groups (13.6% [12/88] AB vs 12.7% [10/79] PFB). PACU morphine requirements and doses were significantly reduced in the PFB group ( P = .004) when compared to the AB group. The VAS was also significantly lower for the PFB patients at 10 pm on POD 0 (4.6 vs 1.6, P PFB 10.1%, P = .51) and there were no significant differences in residual sensory paresthesias (AB 2.3% [2/88] vs PFB 5.1% [4/79], P = .29), motor loss (0% vs 0%), or block site pain and/or erythema (AB 6.9% [6/88] vs PFB 5.1% [4/79], P = .44). The analgesic effect of the PFB lasted significantly longer when compared to the ankle block (AB 14.5 hours vs PFB 20.9 hours, P PFB 4.82/5, P = .68). Regional

  5. The value of single-shot black-blood MR imaging for mapping of the coronary arteries: a comparison of four different orientations during breath-holding and free breathing.

    NARCIS (Netherlands)

    Holland, A.E.; Engelbrecht, M.R.W.; Barentsz, J.O.; Heijstraten, F.M.J.; Goldfarb, J.W.

    2002-01-01

    The value of ECG-gated single-shot black-blood MR imaging for rapid visualization of the origin and course of the coronary arteries was investigated. The study population included 28 patients with known or suspected cardiac disease. ECG-gated single-shot black-blood MR acquisitions were acquired in

  6. Flexible Low-power SiGe HBT Amplifier Circuits for Fast Single-shot Spin Readout

    Science.gov (United States)

    England, Troy; Lilly, Michael; Curry, Matthew; Carr, Stephen; Carroll, Malcolm

    Fast, low-power quantum state readout is one of many challenges facing quantum information processing. Single electron transistors (SETs) are potentially fast, sensitive detectors for performing spin readout of electrons bound to Si:P donors. From a circuit perspective, however, their output impedance and nonlinear conductance are ill suited to drive the parasitic capacitance of coaxial conductors used in cryogenic environments, necessitating a cryogenic amplification stage. We will introduce two new amplifier topologies that provide excellent gain versus power tradeoffs using silicon-germanium (SiGe) heterojunction bipolar transistors (HBTs). The AC HBT allows in-situ adjustment of power dissipation during an experiment and can provide gain in the millikelvin temperature regime while dissipating less than 500 nW. The AC Current Amplifier maximizes gain at nearly 800 A/A. We will also show results of using these amplifiers with SETs at 4 K. This work was performed, in part, at the Center for Integrated Nanotechnologies, a U.S. DOE Office of Basic Energy Sciences user facility. Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a Lockheed-Martin Company, for the U. S. Department of Energy under Contract No. DE-AC04-94AL85000. Flexible Low-power SiGe HBT Amplifier Circuits for Fast Single-shot Spin Readout.

  7. Real-Time, Single-Shot Temporal Measurements of Short Electron Bunches, Terahertz CSR and FEL Radiation

    CERN Document Server

    Berden, G; Van der Meer, A F G

    2005-01-01

    Electro-optic detection of the Coulomb field of electron bunches is a promising technique for single-shot measurements of the bunch length and shape in the sub-picosecond time domain. This technique has been applied to the measurement of 50 MeV electron bunches in the FELIX free electron laser, showing the longitudinal profile of single bunches of around 650 fs FWHM [Phys. Rev. Lett. 93, 114802 (2004)]. The method is non-destructive and real-time, and therefore ideal for online monitoring of the longitudinal shape of single electron bunches. At FELIX we have used it for real-time optimization of sub-picosecond electron bunches. Electro-optic detection has also been used to measure the electric field profiles of far-infrared (or terahertz) optical pulses generated by the relativistic electrons. We have characterised the far-infrared output of the free electron laser, and more recently, we have measured the temporal profile of terahertz optical pulses generated at one of the bending magnets.

  8. Fast and robust automatic calibration for single-shot dual-wavelength digital holography based on speckle displacements.

    Science.gov (United States)

    Khodadad, Davood; Bergström, Per; Hällstig, Emil; Sjödahl, Mikael

    2015-06-01

    The objective of this paper is to describe a fast and robust automatic single-shot dual-wavelength holographic calibration method that can be used for online shape measurement applications. We present a model of the correction in two terms for each lobe, one to compensate the systematic errors caused by off-axis angles and the other for the curvature of the reference waves, respectively. Each hologram is calibrated independently without a need for an iterative procedure or information of the experimental set-up. The calibration parameters are extracted directly from speckle displacements between different reconstruction planes. The parameters can be defined as any fraction of a pixel to avoid the effect of quantization. Using the speckle displacements, problems associated with phase wrapping is avoided. The procedure is shown to give a shape accuracy of 34 μm using a synthetic wavelength of 1.1 mm for a measurement on a cylindrical test object with a trace over a field of view of 18  mm×18  mm.

  9. Silicon-Vacancy Spin Qubit in Diamond: A Quantum Memory Exceeding 10 ms with Single-Shot State Readout

    Science.gov (United States)

    Sukachev, D. D.; Sipahigil, A.; Nguyen, C. T.; Bhaskar, M. K.; Evans, R. E.; Jelezko, F.; Lukin, M. D.

    2017-12-01

    The negatively charged silicon-vacancy (SiV- ) color center in diamond has recently emerged as a promising system for quantum photonics. Its symmetry-protected optical transitions enable the creation of indistinguishable emitter arrays and deterministic coupling to nanophotonic devices. Despite this, the longest coherence time associated with its electronic spin achieved to date (˜250 ns ) has been limited by coupling to acoustic phonons. We demonstrate coherent control and suppression of phonon-induced dephasing of the SiV- electronic spin coherence by 5 orders of magnitude by operating at temperatures below 500 mK. By aligning the magnetic field along the SiV- symmetry axis, we demonstrate spin-conserving optical transitions and single-shot readout of the SiV- spin with 89% fidelity. Coherent control of the SiV- spin with microwave fields is used to demonstrate a spin coherence time T2 of 13 ms and a spin relaxation time T1 exceeding 1 s at 100 mK. These results establish the SiV- as a promising solid-state candidate for the realization of quantum networks.

  10. Single-shot T1 mapping of the corpus callosum: A rapid characterization of fiber bundle anatomy

    Directory of Open Access Journals (Sweden)

    Sabine eHofer

    2015-05-01

    Full Text Available Using diffusion-tensor MRI and fiber tractography the topographic organization of the corpus callosum (CC has been described to comprise 5 segments with fibers projecting into prefrontal (I, premotor and supplementary motor (II, primary motor (III, and primary sensory areas (IV, as well as into parietal, temporal, and occipital cortical areas (V. In order to more rapidly characterize the underlying anatomy of these segments, this study used a novel single-shot T1 mapping method to quantitatively determine T1 relaxation times in the human CC. A region-of-interest analysis revealed a tendency for the lowest T1 relaxation times in the genu and the highest T1 relaxation times in the somatomotor region of the CC. This observation separates regions dominated by myelinated fibers with large diameters (somatomotor area from densely packed smaller axonal bundles (genu with less myelin. The results indicate that characteristic T1 relaxation times in callosal profiles provide an additional means to monitor differences in fiber anatomy, fiber density, and gray matter in respective neocortical areas. In conclusion, rapid T1 mapping allows for a characterization of the axonal architecture in an individual CC in less than 10 s. The approach emerges as a valuable means for studying neocortical brain anatomy with possible implications for the diagnosis of neurodegenerative processes.

  11. Anti-spoof touchless 3D fingerprint recognition system using single shot fringe projection and biospeckle analysis

    Science.gov (United States)

    Chatterjee, Amit; Bhatia, Vimal; Prakash, Shashi

    2017-08-01

    Fingerprint is a unique, un-alterable and easily collected biometric of a human being. Although it is a 3D biological characteristic, traditional methods are designed to provide only a 2D image. This touch based mapping of 3D shape to 2D image losses information and leads to nonlinear distortions. Moreover, as only topographic details are captured, conventional systems are potentially vulnerable to spoofing materials (e.g. artificial fingers, dead fingers, false prints, etc.). In this work, we demonstrate an anti-spoof touchless 3D fingerprint detection system using a combination of single shot fringe projection and biospeckle analysis. For fingerprint detection using fringe projection, light from a low power LED source illuminates a finger through a sinusoidal grating. The fringe pattern modulated because of features on the fingertip is captured using a CCD camera. Fourier transform method based frequency filtering is used for the reconstruction of 3D fingerprint from the captured fringe pattern. In the next step, for spoof detection using biospeckle analysis a visuo-numeric algorithm based on modified structural function and non-normalized histogram is proposed. High activity biospeckle patterns are generated because of interaction of collimated laser light with internal fluid flow of the real finger sample. This activity reduces abruptly in case of layered fake prints, and is almost absent in dead or fake fingers. Furthermore, the proposed setup is fast, low-cost, involves non-mechanical scanning and is highly stable.

  12. Near field flow characteristics of the Bjork-Shiley Monostrut valve in a modified single shot valve chamber.

    Science.gov (United States)

    Manning, Keefe B; Przybysz, T Michael; Fontaine, Arnold A; Tarbell, John M; Deutsch, Steven

    2005-01-01

    In certain mechanical heart valves, cavitation has been shown to develop during closure and rebound, leading to valve damage, blood damage, and strokes. Whereas it is uncertain what causes mechanical heart valve related strokes, some evidence suggests that stable bubbles may be the culprits. Previous work has indicated that vortex cavitation may contribute to stable bubble growth. Therefore, in an effort to understand the vortex cavitation, laser Doppler velocimetry data are collected in a plane parallel to and 3 mm away from the major orifice during closure and rebound of a Bjork-Shiley Monostrut mechanical heart valve. A modified single shot chamber is used that incorporates a more realistic near valve geometry than those used in previous studies. The results show the formation of a vortex during closure, which intensifies during rebound and dissipates during the final closing cycle. A regurgitant jet with mean velocities up to 3 m/s through the clearance gap of the valve provides energy to the vortex. During the final closing cycle, the vortex breaks up into asymmetrical, small scale flow patterns. This study provides further evidence that stable bubble formation may stem from the intense vortex cavitation occurring during valve closure and rebound.

  13. MR imaging of the gastrointestinal tract with half-fourier single-shot fast spin echo (SSFSE)

    International Nuclear Information System (INIS)

    Boku, Houjun; Takehara, Yasuo; Isoda, Haruo; Isogai, Satoshi; Kaneko, Masao

    1999-01-01

    Our objective was to implement a non-invasive magnetic resonance imaging (MRI) technique combined with concentrated milk ingestion for depicting the gastrointestinal (GI) tract and detecting gastrointestinal motility and transit. The half-Fourier SSFSE (single-shot fast spin echo) sequence was optimized on the basis of a phantom study. In order to determine the feasibility of milk ingestion as a substitute for contrast medium, ten human volunteers were examined with SSFSE after two types of liquid ingestion (i.e., milk and water). The snapshot images provided subsecond data acquisition for each coronal plane, allowing visualization of peristalsis in the gastrointestinal tract in an almost real-time fashion, without motion-related image degradation, as would normally be seen using conventional MRI. There was no significant difference between concentrated milk and water in terms of depiction of the upper gastrointestinal tract; however, 10 min and 30 min after ingestion, concentrated milk showed better delineation of the intestine than that observed after water ingestion (p<0.01). MR gastrointestinal imaging is a non-invasive method that allows gastrointestinal depiction as well as analysis of motility and passage. Especially with concentrated milk ingestion, the distal intestines were well depicted with adequate contrast filling and distention. (author)

  14. Poloxamer 407-chitosan grafted thermoresponsive hydrogels achieve synchronous and sustained release of antigen and adjuvant from single-shot vaccines.

    Science.gov (United States)

    Bobbala, Sharan; Gibson, Blake; Gamble, Allan B; McDowell, Arlene; Hook, Sarah

    2018-03-02

    Sustained release vaccine delivery systems may enhance the immunogenicity of subunit vaccines and reduce the need for multiple vaccinations. The aim of this study was to develop a thermoresponsive hydrogel using poloxamer 407-chitosan (CP) grafted copolymer as a delivery system for single-shot sustained release vaccines. The CP copolymer was synthesized using 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide (EDC) and N-hydroxysuccinimide (NHS) chemistry. The CP copolymer was a free flowing solution at ambient temperature and transformed rapidly into a gel at body temperature. The hydrogels were loaded with vaccine antigen and adjuvants or the vaccine components were encapsulated in poly (lactic-co-glycolic acid) nanoparticles (PLGA-NP) in order to ensure synchronous release. The CP hydrogels were stable for up to 18 days in vitro. Release of both nanoparticles and the individual components was complete, with release of the individual components being modulated by incorporation into nanoparticles. In vivo, a single dose of CP hydrogel vaccine induced strong, long lasting, cellular and humoral responses that could protect against the development of tumors in a murine melanoma model. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  15. MR imaging of the gastrointestinal tract with half-fourier single-shot fast spin echo (SSFSE)

    Energy Technology Data Exchange (ETDEWEB)

    Boku, Houjun; Takehara, Yasuo; Isoda, Haruo; Isogai, Satoshi; Kaneko, Masao [Hamamatsu Univ. School of Medicine, Shizuoka (Japan)

    1999-04-01

    Our objective was to implement a non-invasive magnetic resonance imaging (MRI) technique combined with concentrated milk ingestion for depicting the gastrointestinal (GI) tract and detecting gastrointestinal motility and transit. The half-Fourier SSFSE (single-shot fast spin echo) sequence was optimized on the basis of a phantom study. In order to determine the feasibility of milk ingestion as a substitute for contrast medium, ten human volunteers were examined with SSFSE after two types of liquid ingestion (i.e., milk and water). The snapshot images provided subsecond data acquisition for each coronal plane, allowing visualization of peristalsis in the gastrointestinal tract in an almost real-time fashion, without motion-related image degradation, as would normally be seen using conventional MRI. There was no significant difference between concentrated milk and water in terms of depiction of the upper gastrointestinal tract; however, 10 min and 30 min after ingestion, concentrated milk showed better delineation of the intestine than that observed after water ingestion (p<0.01). MR gastrointestinal imaging is a non-invasive method that allows gastrointestinal depiction as well as analysis of motility and passage. Especially with concentrated milk ingestion, the distal intestines were well depicted with adequate contrast filling and distention. (author)

  16. Magnetic resonance urography in pediatrics: utilization of ultrafast single-shot spin echo sequences; Urografia por resonancia magnetic en pediatria: utilizacion de las secuencias ultrarrapidas single shot en eco del espin

    Energy Technology Data Exchange (ETDEWEB)

    Martin, C.; Martin, J.; Duran, C. [Unidad de Diagnostico por la Imagen de Alta Tecnologia (UDIAT). Sabadell (Spain); Rigol, S.; Rojo, J. C. [Corporacion Sanatiaria Parc Tauli. Sabadell (Spain)

    1999-07-01

    To determine the value of magnetic resonance urography (MRU) using ultrafast single-shot (SS) rapid acquisition with relaxation enhancement (RARE) and half-Fourier (HF) SS-RARE (SS-HF-RARE or HASTE) in the evaluation of congenital urinary tract anomalies in pediatric patients, and their possible application as alternatives to intravenous urography (IVU). Eighteen children (11 boys and 7 girls) aged 2 months to 15 years (mean: 5 years) with a total of 19 congenital urinary tract anomalies were studies by MU using SS-RARE and HASTE sequences in a 1 Tesla scanner. All the patients had previously been studies by ultrasound (US) and IVU. Twelve patients required anesthesia. The images were acquired by means of a HASTE sequence with multisection technique (TR, infinite; TE{sub e}f, 87 msec; echo train, 128; interval between echoes, 10.9 msec; total acquisition time, 13 sections/12 seconds), and SS-RARE (TR, infinite; TE{sub e}f, 1.100 msec; echo train, 240, and acquisition time, 7 seconds). Four radiologists evaluated the images independently; two who reviewed the IV images in consensus and two who reviewed the MRU images in consensus. The images were evaluated to assess the dilatation of the urinary tract and their utility in detecting the level and cause of the obstruction. MRU images revealed the urinary tract dilation, the level of the obstruction and the type of anomaly in 18 patients (100%), while IVU provided this information in only 10 [ sensitivity, 53%, 95% confidence interval (29%, 76%)]. The mean time required for MRU was 20 minutes (range: 7 to 30 minutes), while that of IVU was 1,242 minutes (range: 45 to 1,440 minutes). MRU using ultrafast single-short spin echo sequences is a rapid and effective technique that permits and excellent evaluation of congenital urinary tract anomalies in pediatric patients and does not require the administration of contrast media or ionizing radiation. (Author) 10 refs.

  17. Non-contrast-enhanced imaging of haemodialysis fistulas using quiescent-interval single-shot (QISS) MRA: a feasibility study

    International Nuclear Information System (INIS)

    Okur, A.; Kantarci, M.; Karaca, L.; Yildiz, S.; Sade, R.; Pirimoglu, B.; Keles, M.; Avci, A.; Çankaya, E.; Schmitt, P.

    2016-01-01

    Aim: To assess the efficiency of a novel quiescent-interval single-shot (QISS) technique for non-contrast-enhanced magnetic resonance angiography (MRA) of haemodialysis fistulas. Materials and methods: QISS MRA and colour Doppler ultrasound (CDU) images were obtained from 22 haemodialysis patients with end-stage renal disease (ESRD). A radiologist with extensive experience in vascular imaging initially assessed the fistulas using CDU. Two observers analysed each QISS MRA data set in terms of image quality, using a five-point scale ranging from 0 (non-diagnostic) to 4 (excellent), and lumen diameters of all segments were measured. Results: One hundred vascular segments were analysed for QISS MRA. Two anastomosis segments were considered non-diagnostic. None of the arterial or venous segments were evaluated as non-diagnostic. The image quality was poorer for the anastomosis level compared to the other segments (p<0.001 for arterial segments, and p<0.05 for venous segments), while no significant difference was determined for other vascular segments. Conclusion: QISS MRA has the potential to provide valuable complementary information to CDU regarding the imaging of haemodialysis fistulas. In addition, QISS non-enhanced MRA represents an alternative for assessment of haemodialysis fistulas, in which the administration of iodinated or gadolinium-based contrast agents is contraindicated. - Highlights: • Close monitoring and early intervention in hemodialysis fistulas may prolong longevity fistulas. • DopplerUS, contrast enhanced CT and MRI are using assessment of hemodialysis fistulas. • QISS nonenhanced MR angiography represents an alternative for assessment of hemodialysis fistulas.

  18. Single-shot measurements of low emittance beams from laser-plasma accelerators comparing two triggered injection methods

    Science.gov (United States)

    van Tilborg, Jeroen

    2017-10-01

    The success of laser plasma accelerator (LPA) based applications, such as a compact x-ray free electron laser (FEL), relies on the ability to produce electron beams with excellent 6D brightness, where brightness is defined as the ratio of charge to the product of the three normalized emittances. As such, parametric studies of the emittance of LPA generated electron beams are essential. Profiting from a stable and tunable LPA setup, combined with a carefully designed single-shot energy-dispersed emittance diagnostic, we present a direct comparison of charge dependent emittance measurements of electron beams generated by two different injection mechanisms: ionization injection and shock-induced density down-ramp injection. Both injection mechanisms have gained in popularity in recent years due to their demonstrated stable LPA performance. For the down-ramp injection configuration, normalized emittances a factor of two lower were recorded: less than 1 micron at spectral charge densities up to 2 pC/MeV. For both injection mechanisms, a contributing correlation of space charge to the emittance was identified. This measurement technique in general, and these results specifically, are critical to the evaluation of LPA injection methods and development of high-quality LPA beam lines worldwide. This work is supported by the U.S. DOE under Contract No. DE-AC02-05CH11231, by the U.S. DOE NNSA, DNN R&D (NA22), by the National Science Foundation under Grant No. PHY-1415596, and by the Gordon and Betty Moore Foundation under Grant ID GBMF4898.

  19. Utility of single shot fast spin echo technique in evaluating pancreaticobiliary diseases: T2-weighted image and magnetic resonance cholangiopancreatography

    International Nuclear Information System (INIS)

    Choi, Byoung Wook; Kim, Myeong Jin; Chung, Jae Bok; Ko, Heung Kyu; Kim, Dong Joon; Kim, Joo Hee; Chung, Jae Joon; Yoo, Hyung Sik; Lee, Jong Tae

    1999-01-01

    To evaluate the accuracy of T2-weighted imaging an MR cholangiopancreatography using the single shot fast spin-echo technique for evaluating pancreaticobiliary disease. Between March and July 1997, axial and coronal T2-weighted images(TE: 80-200 msec) and MR cholangiopancreatograms (TE: 800-1200 msec) were obtained in two ways [single slab (thickness: 30-50 mm) and multislice acquisition under chemical fat saturation] using SSFSE pulse sequencing in 131 cases of suspected pancreati-cobiliary disease. The accuracy of SSFSE MR imaging was assessed in 89 lesions of 74 patients [male, 48; female, 26; age range, 30-86 (mean, 59) years] confirmed surgicopathologically (50 lesions in 39 patients) and clinically (39 lesions in 35 patients). Two radiologists reviewed the MR images and diagnosis was determined by consensus. Correct diagnosis was confirmed in 84 of 89 lesions (94%). Seven lesions were falsely interpreted, false positive and false negative results accounting for two and five cases, respectively. Two pancreatic cancers were misdiagnosed as pancreatitis and a cancer of the proximal common bile duct(CBD) was interpreted as a distal CBD cancer. The sensitivity of SSFSE MR imaging for malignancy was 93 %. One CBD stone revealed by endoscopic retrograde cholangiopancreatography (ERCP) was not detected on MR images. In contrast, a stone in the CBD seen on MR images was not apparent on subsequent ERCP. Sensitivity and specificity for calculous disease were 96% and 99.7%, respectively. A benign stricture of the ampulla of Vater was falsely interpreted as normal, and correct diagnosis was possible in two falsely diagnosed cases when MR images were reviewed retrospectively. The combination of T2-weighted and cholangiographic images using SSFSE is an accurate method for diagnosing pancreatcobiliary diseases

  20. Feasibility study of a single-shot 3D electron bunch shape monitor with an electro-optic sampling technique

    Directory of Open Access Journals (Sweden)

    Yuichi Okayasu

    2013-05-01

    Full Text Available We developed a three-dimensional electron bunch charge distribution (3D-BCD monitor with single-shot detection, and a spectral decoding based electro-optic (EO sampling technique for a nondestructive monitor enables real-time reconstruction of the three-dimensional distribution of a bunch charge. We realized three goals by simultaneously probing a number of Pockels EO crystals that surround the electron beam axis with hollow and radial polarized laser pulses. First, we performed a feasibility test as a simple case of a 3D-BCD monitor probing two ZnTe crystals as EO detectors installed on the opposite angle to the electron beam axis and confirmed that we simultaneously obtained both EO signals. Since the adopted hollow probe laser pulse is not only radially polarized but also temporally shifted azimuthally, some disorders in the radial polarization distribution of such a laser pulse were numerically analyzed with a plane-wave expansion method. Based on the above investigations, the 3D-BCD monitor is feasible both in experimental and numerical estimations. Furthermore, we previously developed a femtosecond response organic crystal as a Pockels EO detector and a broadband probe laser (≥350  nm in FWHM; the 3D-BCD monitor realizes 30- to 40-fs (FWHM temporal resolution. Eventually, the monitor is expected to be equipped in such advanced accelerators as XFEL to measure and adjust the electron bunch charge distribution in real time. The 3D-BCD measurement works as a critical tool to provide feedback to seeded FELs.

  1. The mixed block/event-related design.

    Science.gov (United States)

    Petersen, Steven E; Dubis, Joseph W

    2012-08-15

    Neuroimaging studies began using block design and event-related design experiments. While providing many insights into brain functions, these fMRI design types ignore components of the BOLD signal that can teach us additional elements. The development of the mixed block/event-related fMRI design allowed for a fuller characterization of nonlinear and time-sensitive neuronal responses: for example, the interaction between block and event related factors and the simultaneous extraction of transient activity related to trials and block transitions and sustained activity related to task-level processing. This review traces the origins of the mixed block/event-related design from conceptual precursors to a seminal paper and on to subsequent studies using the method. The review also comments on aspects of the experimental design that must be considered when attempting to use the mixed block/event-related design. When taking into account these considerations, the mixed block/event-related design allows fuller utilization of the BOLD signal allowing deeper interpretation of how regions of the brain function on multiple timescales. Copyright © 2011 Elsevier Inc. All rights reserved.

  2. Radiation damage to amorphous carbon thin films irradiated by multiple 46.9 nm laser shots below the single-shot damage threshold

    Czech Academy of Sciences Publication Activity Database

    Juha, Libor; Hájková, Věra; Chalupský, Jaromír; Vorlíček, Vladimír; Ritucci, A.; Reale, A.; Zuppella, P.; Störmer, M.

    2009-01-01

    Roč. 105, č. 9 (2009), 093117/1-093117/3 ISSN 0021-8979 R&D Projects: GA AV ČR KAN300100702; GA MŠk LC510; GA MŠk(CZ) LC528; GA MŠk LA08024; GA AV ČR IAA400100701 Institutional research plan: CEZ:AV0Z10100523 Keywords : single-shot damage threshold * multiple-shot exposure damage * amorphous carbon * radiation erosion * capillary-discharge XUV laser Subject RIV: BH - Optics, Masers, Lasers Impact factor: 2.072, year: 2009

  3. Wavefront Analysis of Nonlinear Self-Amplified Spontaneous-Emission Free-Electron Laser Harmonics in the Single-Shot Regime

    Energy Technology Data Exchange (ETDEWEB)

    Bachelard, R.; Chubar, O.; Mercere, P.; Idir, M.; Couprie, M.E.; Lambert, G.; Zeitoun, Ph.; Kimura, H.; Ohashi, H.; Higashiya, A.; Yabashi, M.; Nagasono, M.; Hara, T. and Ishikawa, T.

    2011-06-08

    The single-shot spatial characteristics of the vacuum ultraviolet self-amplified spontaneous emission of a free electron laser (FEL) is measured at different stages of amplification up to saturation with a Hartmann wavefront sensor. We show that the fundamental radiation at 61.5 nm tends towards a single-mode behavior as getting closer to saturation. The measurements are found in good agreement with simulations and theory. A near diffraction limited wavefront was measured. The analysis of Fresnel diffraction through the Hartmann wavefront sensor hole array also provides some further insight for the evaluation of the FEL transverse coherence, of high importance for various applications.

  4. Angle-resolved spectral Fabry-Pérot interferometer for single-shot measurement of refractive index dispersion over a broadband spectrum

    Science.gov (United States)

    Dong, J. T.; Ji, F.; Xia, H. J.; Liu, Z. J.; Zhang, T. D.; Yang, L.

    2018-01-01

    An angle-resolved spectral Fabry-Pérot interferometer is reported for fast and accurate measurement of the refractive index dispersion of optical materials with parallel plate shape. The light sheet from the wavelength tunable laser is incident on the parallel plate with converging angles. The transmitted interference light for each angle is dispersed and captured by a 2D sensor, in which the rows and the columns are used to simultaneously record the intensities as a function of wavelength and incident angle, respectively. The interferogram, named angle-resolved spectral intensity distribution, is analyzed by fitting the phase information instead of finding the fringe peak locations that present periodic ambiguity. The refractive index dispersion and the physical thickness can be then retrieved from a single-shot interferogram within 18 s. Experimental results of an optical substrate standard indicate that the accuracy of the refractive index dispersion is less than 2.5  ×  10-5 and the relative uncertainty of the thickness is 6  ×  10-5 mm (3σ) due to the high stability and the single-shot measurement of the proposed system.

  5. Infrared-spectroscopic single-shot laser mapping ellipsometry: Proof of concept for fast investigations of structured surfaces and interactions in organic thin films

    Science.gov (United States)

    Furchner, Andreas; Kratz, Christoph; Gkogkou, Dimitra; Ketelsen, Helge; Hinrichs, Karsten

    2017-11-01

    We present a novel infrared-spectroscopic laser mapping ellipsometer based on a single-shot measurement concept. The ellipsometric set-up employs multiple analyzers and detectors to simultaneously measure the sample's optical response under different analyzer azimuths. An essential component is a broadly tunable quantum cascade laser (QCL) covering the important marker region of 1800-1540 cm-1. The ellipsometer allows for fast single-wavelength as well as spectroscopic studies with thin-film sensitivity at temporal resolutions of 60 ms per wavelength. We applied the single-shot mapping ellipsometer for the characterization of metal-island enhancement surfaces as well as of molecular interactions in organic thin films. In less than 3 min, a linescan with 1600 steps revealed profile and infrared-enhancement properties of a gradient gold-island film for sensing applications. Spectroscopic measurements were performed to probe the amide I band of thin films of poly(N-isopropylacrylamide) [PNIPAAm], a stimuli-responsive polymer for bioapplications. The QCL spectra agree well with conventional FT-IR ellipsometric results, showing different band components associated with hydrogen-bond interactions between polymer and adsorbed water. Multi-wavelength ellipsometric maps were used to analyze homogeneity and surface contaminations of the polymer films.

  6. Diffusion-weighted MRI of the cervical spinal cord using a single-shot fast spin-echo technique: findings in normal subjects and in myelomalacia

    Energy Technology Data Exchange (ETDEWEB)

    Tsuchiya, K.; Katase, S.; Fujikawa, A.; Hachiya, J. [Department of Radiology, Kyorin University School of Medicine, 6-20-2 Shinkawa, Mitaka, 181-8611, Tokyo (Japan); Kanazawa, H. [Toshiba Corporation, 1-1-1 Shibaura, Minato-ku, 105-8001, Tokyo (Japan); Yodo, K. [Toshiba Medical Systems, 3-26-5 Hongo, Bunkyo-ku, 113-8456, Tokyo (Japan)

    2003-02-01

    We have implemented a new diffusion-weighted MRI (DWI) sequence based on the single-shot fast spin-echo technique. We hypothesised that this would add information to conventional MRI for diagnosis of lesions of the cervical spinal cord. DWI was performed using a technique in which echo collection after the application of motion-probing gradients was done in the same manner as in the single-shot fast spin-echo technique. We first imaged six healthy volunteers to demonstrate the cervical spinal cord using the sequence. Then we applied the sequence to 12 patients with cervical myelomalacia due to chronic cord compression. The spinal cord was well seen in all subjects without the distortion associated with echo-planar DWI. In the patients, lesions appeared as areas of low- or isointense signal on DWI. Calculated apparent diffusion coefficients of the lesions (3.30{+-}0.38 x 10{sup -3} mm{sup 2}/s) were significantly higher than those of normal volunteers (2.26{+-}0.08 x 10{sup -3} mm{sup 2}/s). Increased diffusion in areas of cervical myelomalacia, suggesting irreversible damage, can be detected using this technique. (orig.)

  7. A single-shot T2mapping protocol based on echo-split gradient-spin-echo acquisition and parametric multiplexed sensitivity encoding based on projection onto convex sets reconstruction.

    Science.gov (United States)

    Chu, Mei-Lan; Chang, Hing-Chiu; Oshio, Koichi; Chen, Nan-Kuei

    2018-01-01

    To develop a high-speed T 2 mapping protocol that is capable of accurately measuring T 2 relaxation time constants from a single-shot acquisition. A new echo-split single-shot gradient-spin-echo (GRASE) pulse sequence is developed to acquire multicontrast data while suppressing signals from most nonprimary echo pathways in Carr-Purcell-Meiboom-Gill (CPMG) echoes. Residual nonprimary pathway signals are taken into consideration when performing T 2 mapping using a parametric multiplexed sensitivity encoding based on projection onto convex sets (parametric-POCSMUSE) reconstruction method that incorporates extended phase graph modeling of GRASE signals. The single-shot echo-split GRASE-based T 2 mapping procedure was evaluated in human studies at 3 Tesla. The acquired data were compared with reference data obtained with a more time-consuming interleaved spin-echo echo planar imaging protocol. T 2 maps derived from conventional single-shot GRASE scans, in which nonprimary echo pathways were not appropriately addressed, were also evaluated. Using the developed single-shot T 2 mapping protocol, quantitatively accurate T 2 maps can be obtained with a short scan time (parametric-POCSMUSE reconstruction. Magn Reson Med 79:383-393, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  8. Event related potentials in children of alcoholics.

    Science.gov (United States)

    Naziel, B; Yavaş, G; Arikan, Z; Ozon, O; Aksoy Ozmenek, O; Irkeç, C

    2007-09-01

    Assessment of ERPs (Event Related Potentials) is a special area of interest in research on vulnerability to alcoholism in human subjects. ERP not only provide information about potential neurofunctional anomalies in healthy individuals, but also relate those neurofunctional characteristics to the cognitive process involved. The aim of the present study is to evaluate the effects of chronic alcoholism and alcoholism risk on children of alcoholic fathers by using ERP parameters. 24 children of alcoholic fathers (9 boys, 15 girls) with a mean age of 18 +/- 3 (range: 15-25) and 17 control subjects (children of non-alcoholic fathers with out a family history of alcoholism) were included to the study. The age range was from 15 to 25 (mean: 21 +/- 3). N200 potential latency recorded from the parietal electrode position was significantly prolonged (p = 0.032) and amplitudes of P200 potential also recorded from the parietal region was significantly low (p = 0.043) relative to controls. However, the rest of the event-related potential parameters including P300 latency and amplitudes recorded from FZ, CZ, PZ electrode positions did not differ significantly from the children of non-alcoholic fathers. The difference in our results from the previous studies may be due to various factors. Genetic, gender, environmental, educational and social factors may have an overall effect on ERP and we believe these factors may be the cause of the differences seen in our study when compared to the previous ones. We believe the gender differences in our group may have had effected the overall results. Consecutive studies with more subject participation are needed to confirm and settle this issue.

  9. Single-shot characterization of enzymatic reaction constants Km and kcat by an acoustic-driven, bubble-based fast micromixer

    Science.gov (United States)

    Xie, Yuliang; Ahmed, Daniel; Lapsley, Michael Ian; Lin, Sz-Chin Steven; Nawaz, Ahmad Ahsan; Wang, Lin; Huang, Tony Jun

    2014-01-01

    In this work we present an acoustofluidic approach for rapid, single-shot characterization of enzymatic reaction constants Km and kcat. The acoustofluidic design involves a bubble anchored in a horseshoe structure which can be stimulated by a piezoelectric transducer to generate vortices in the fluid. The enzyme and substrate can thus be mixed rapidly, within 100 ms, by the vortices to yield the product. Enzymatic reaction constants Km and kcat can then be obtained from the reaction rate curves for different concentrations of substrate while holding the enzyme concentration constant. We studied the enzymatic reaction for β-galactosidase and its substrate (resorufin β-D-galactopyranoside) and found Km and kcat to be 333±130 =M and 64±8 s−1 respectively, which are in agreement with published data. Our approach is valuable for studying the kinetics of high-speed enzymatic reactions and other chemical reactions. PMID:22880882

  10. Observation of single artificial atom optical bi-stability and its application to single-shot readout in circuit quantum electrodynamics

    Science.gov (United States)

    Sun, Luyan; Ginossar, Eran; Guy, Mikhael; Reed, Matthew; Paik, Hanhee; Bishop, Lev S.; Sears, Adam; Petrenko, Andrei; Brecht, Teresa; Frunzio, Luigi; Girvin, Steven; Schoelkopf, Robert

    2012-02-01

    The high power transient behavior of superconducting qubit-cavity systems has recently been used to perform high fidelity readout of transmon qubits [1]. We show that in the steady state, the system exhibits a bi-stable behavior that can be observed on the single-shot level, with the cavity state switching stochastically between dim and bright states. The switching times are shown to be long compared to the cavity and qubit lifetimes. Some features of the bi-stability can be explained by mean field theory, while its switching dynamics is studied with large scale simulations. Understanding these dynamics will be crucial for studying the transient response, an essential aspect of the qubit readout. We will discuss progress on optimizing readout by shaping the measurement pulse. [4pt] [1] M. D. Reed, L. DiCarlo, B. R. Johnson, L. Sun, D. I. Schuster, L. Frunzio, and R. J. Schoelkopf, Phys. Rev. Lett. 105, 173601 (2010)

  11. Measurement of the X-ray Spectrum of a Free Electron Laser with a Wide-Range High-Resolution Single-Shot Spectrometer

    Directory of Open Access Journals (Sweden)

    Yuichi Inubushi

    2017-06-01

    Full Text Available We developed a single-shot X-ray spectrometer for wide-range high-resolution measurements of Self-Amplified Spontaneous Emission (SASE X-ray Free Electron Laser (XFEL pulses. The spectrometer consists of a multi-layer elliptical mirror for producing a large divergence of 22 mrad around 9070 eV and a silicon (553 analyzer crystal. We achieved a wide energy range of 55 eV with a fine spectral resolution of 80 meV, which enabled the observation of a whole SASE-XFEL spectrum with fully-resolved spike structures. We found that a SASE-XFEL pulse has around 60 longitudinal modes with a pulse duration of 7.7 ± 1.1 fs.

  12. Clinical single-shot diffusion-weighted MRI of the human brain on a short-bore medium-field imager

    International Nuclear Information System (INIS)

    Loevblad, K.O.; Remonda, L.; Schneider, J.; Goenner, F.; Schroth, G.; Heid, O.

    1999-01-01

    Diffusion-weighted MRI (DWI) is becoming important for assessment of acute stroke. Until recently single-shot DWI required expensive technology such as echo-planar imaging (EPI) available only at some research sites. A new medium-field (1.0 T) short-bore MR imager has been developed with which DWI data sets can be acquired. We prospectively studied 169 patients on this 1.0 T commercial system. After conventional imaging, DWI was performed with a single-shot multi-slice sequence with b values 0 an 900 s/mm 2 , and with the gradients switched in three directions. The apparent diffusion coefficients were calculated with online calculation software. There were 50 patients with totally normal MRI, and 17 had strokes, these strokes were detected as areas of high signal on the images at a maximal b value. There was a drop in the ADC in ischaemic regions: in subacute infarcts, the values were between 0.41 and 0.531 x 10 - 3 mm 2 /s. In old infarcts the ADC was 1.15 x 10 - 3 mm 2 /s. Cerebrospinal fluid (CSF) gave low signal whereas areas in the brain had more intermediate intensities (CSF: 3.00; deep white matter: 0.75, cortical grey matter: 0.80, basal ganglia (thalamus): 0.70 and cerebellar white matter: 0.65 x 10 - 3 mm 2 /s). Anisotropy was detected as areas of restricted diffusion along the tracts. These preliminary data show that DWI can be aquired successfully on a medium-field short-bore system. This should allow the technique to be implemented at more sites, therefore facilitating the diagnosis of acute stroke and rendering early intervention feasible. (orig.)

  13. Quantitative analysis of the breath-holding half-Fourier acquisition single-shot turbo spin-echo technique in abdominal MRI

    Science.gov (United States)

    Dong, Kyung-Rae; Goo, Eun-Hoe; Lee, Jae-Seung; Chung, Woon-Kwan

    2013-01-01

    A consecutive series of 50 patients (28 males and 22 females) who underwent hepatic magnetic resonance imaging (MRI) from August to December 2011 were enrolled in this study. The appropriate parameters for abdominal MRI scans were determined by comparing the images (TE = 90 and 128 msec) produced using the half-Fourier acquisition single-shot turbo spin-echo (HASTE) technique at different signal acquisition times. The patients consisted of 15 normal patients, 25 patients with a hepatoma and 10 patients with a hemangioma. The TE in a single patient was set to either 90 msec or 128 msec. This was followed by measurements using the four normal rendering methods of the biliary tract system and the background signal intensity using the maximal signal intensity techniques in the liver, spleen, pancreas, gallbladder, fat, muscles and hemangioma. The signal-to-noise and the contrast-to-noise ratios were obtained. The image quality was assessed subjectively, and the results were compared. The signal-to-noise and the contrast-to-noise ratios were significantly higher at TE = 128 msec than at TE = 90 when diseases of the liver, spleen, pancreas, gallbladder, and fat and muscles, hepatocellular carcinomas and hemangiomas, and rendering the hepatobiliary tract system based on the maximum signal intensity technique were involved (p breath-hold half-Fourier acquisition single-shot turbo spin-echo (HASTE) was found to be effective in illustrating the abdominal organs for TE = 128 msec. Overall, the image quality at TE = 128 msec was better than that at TE = 90 msec due to the improved signal-to-noise (SNR) and contrast-to-noise (CNR) ratios. Overall, the HASTE technique for abdominal MRI based on a high-magnetic field (3.0 T) at a TE of 128 msec can provide useful data.

  14. Focal liver lesion detection and characterization: Comparison of non-contrast enhanced and SPIO-enhanced diffusion-weighted single-shot spin echo echo planar and turbo spin echo T2-weighted imaging

    NARCIS (Netherlands)

    Coenegrachts, Kenneth; Matos, Celso; ter Beek, Léon; Metens, Thierry; Haspeslagh, Marc; Bipat, Shandra; Stoker, Jaap; Rigauts, Hans

    2009-01-01

    Purpose: To compare lesion conspicuity and image quality between single-shot spin echo echo planar imaging (SS SE-EPI) before, immediately and 5 min after intravenous (IV) injection of superparamagnetic iron oxide (SPIO) for detecting and characterizing focal liver lesions (FLLs). Materials and

  15. Optimization of mass spectrometric parameters improve the identification performance of capillary zone electrophoresis for single-shot bottom-up proteomics analysis.

    Science.gov (United States)

    Zhang, Zhenbin; Dovichi, Norman J

    2018-02-25

    The effects of MS1 injection time, MS2 injection time, dynamic exclusion time, intensity threshold, and isolation width were investigated on the numbers of peptide and protein identifications for single-shot bottom-up proteomics analysis using CZE-MS/MS analysis of a Xenopus laevis tryptic digest. An electrokinetically pumped nanospray interface was used to couple a linear-polyacrylamide coated capillary to a Q Exactive HF mass spectrometer. A sensitive method that used a 1.4 Th isolation width, 60,000 MS2 resolution, 110 ms MS2 injection time, and a top 7 fragmentation produced the largest number of identifications when the CZE loading amount was less than 100 ng. A programmable autogain control method (pAGC) that used a 1.4 Th isolation width, 15,000 MS2 resolution, 110 ms MS2 injection time, and top 10 fragmentation produced the largest number of identifications for CZE loading amounts greater than 100 ng; 7218 unique peptides and 1653 protein groups were identified from 200 ng by using the pAGC method. The effect of mass spectrometer conditions on the performance of UPLC-MS/MS was also investigated. A fast method that used a 1.4 Th isolation width, 30,000 MS2 resolution, 45 ms MS2 injection time, and top 12 fragmentation produced the largest number of identifications for 200 ng UPLC loading amount (6025 unique peptides and 1501 protein groups). This is the first report where the identification number for CZE surpasses that of the UPLC at the 200 ng loading level. However, more peptides (11476) and protein groups (2378) were identified by using UPLC-MS/MS when the sample loading amount was increased to 2 μg with the fast method. To exploit the fast scan speed of the Q-Exactive HF mass spectrometer, higher sample loading amounts are required for single-shot bottom-up proteomics analysis using CZE-MS/MS. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. [In-phase and out-of-phase single-shot magnetization-prepared gradient recalled echo: description and optimization of technique at 1.5 T].

    Science.gov (United States)

    Ramalho, M; Herédia, V; de Campos, R O P; de Toni, M; Dale, B M; Semelka, R C

    2014-01-01

    To implement in-phase and out-of-phase (IP/OP) techniques with Magnetization-Prepared Gradient Recalled Echo (MP-GRE) and to evaluate the feasibility and diagnostic image quality among pre and post-optimized MP-GRE sequences, including patients unable to cooperate with breath-hold requirements. Institutional review board approval with waiver of informed consent was obtained for this HIPAA-compliant retrospective study. Two groups of patients were included in the study, before and after optimization of MP-GRE parameters, with seventy-three (24 noncooperative/49 cooperative) and sixty-four (22 noncooperative/42 cooperative) consecutive patients, respectively. The motion-insensitive sequence used in this study was a single-shot 2D MP-GRE. Two radiologists qualitatively evaluated the sequences to identify the presence of phase cancellation artifact in OP images and to determine image quality, extent of artifacts (respiratory ghosting, bounce-point artifact, spatial misregistration and pixel graininess) and lesion conspicuity on the various sequences. The ability to visually detect liver steatosis and fatty adrenal adenomas was evaluated. Qualitative analyses were compared using the Wilcoxon and Mann-Whitney tests. There were statistically significant differences between all MP-GRE sequences concerning phase cancellation artifact (P<.0001) which was present in MP-GRE OP sequences and negligible to absent in the pre (IP1) and post-optimized (IP2) MP-GRE IP sequences, respectively, in all patients. Bounce point artifacts were significantly more pronounced in MP-GRE IP1 (P<.0001). Spatial misregistration was slightly more prominent in noncooperative patients with MP-GRE IP2 (P=.0027). MP-GRE OP and MP-GRE IP2 showed significantly higher overall image quality (P<.0001). MP-GRE sequences subjectively identified hepatic steatosis (n=20) and adrenal adenomas (n=5) based on signal loss from IP to OP sequence. Single shot IP/OP MP-GRE is feasible and allows motion resistant

  17. Single shot spinal anesthesia with very low hyperbaric bupivacaine dose (3.75 mg) for hip fracture repair surgery in the elderly. A randomized, double blinded study.

    Science.gov (United States)

    Errando, C L; Peiró, C M; Gimeno, A; Soriano, J L

    2014-11-01

    Single shot spinal anesthesia is used worldwide for hip fracture repair surgery in the elderly. Arterial hypotension is a frequent adverse effect. We hypothesized that lowering local anesthetics dose could decrease the incidence of arterial hypotension, while maintaining quality of surgical anesthesia. In a randomized double blinded study, 66 patients over the age of 65 years, with hip fracture needing surgical repair, were assigned to B0.5 group 7.5mg hyperbaric bupivacaine 5mg/ml (control group), and B0.25 group 3.75mg hyperbaric bupivacaine 2.5mg/ml (study group). Sensory and motor block level, and hemodynamic parameters including blood presure, heart rate and vasopressor dose administration were registered, along with rescue anesthesia needs, the feasibility of surgery, its duration, and regression time of sensory anesthesia to T12. After exclusions, 61 patients were included in the final analysis. Arterial hypotension incidence was lower in the B0.25 group (at the 5, 10, and 15min determinations), and a lower amount of vasopressor drugs was needed (mean accumulated ephedrine dose 1.6mg vs. 8.7mg in the B0.5 group, p<0.002). Sensory block regression time to T12 was shorter in the B0.25 group, mean 78.6±23.6 (95% CI 51.7-110.2)min vs. 125.5±37.9 (95% CI 101.7-169.4)min in the B0.5 group, p=0.033. All but one patient in the B0.25 group were operated on under the anesthetic procedure first intended. No rescue anesthesia was needed. Lowering bupivacaine dose for single shot spinal anesthesia for hip fracture repair surgery in elderly patients was effective in decreasing the occurrence of arterial hypotension and vasopressor use, while intraoperative quality remained. Copyright © 2014 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. Nonenhanced ECG-gated quiescent-interval single-shot MRA (QISS-MRA) of the lower extremities: Comparison with contrast-enhanced MRA

    Energy Technology Data Exchange (ETDEWEB)

    Klasen, J. [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Blondin, D., E-mail: blondin@med.uni-duesseldorf.de [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Schmitt, P. [Siemens AG, Healthcare Sector, Erlangen (Germany); Bi, X. [Siemens Healthcare, Chicago, IL (United States); Sansone, R. [Department of Cardiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Wittsack, H.-J.; Kroepil, P.; Quentin, M.; Kuhlemann, J.; Miese, F. [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Heiss, C.; Kelm, M. [Department of Cardiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany); Antoch, G.; Lanzman, R.S. [Department of Diagnostic and Interventional Radiology, University of Duesseldorf, Medical Faculty, Duesseldorf (Germany)

    2012-05-15

    Aim: To evaluate electrocardiogram (ECG)-gated quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) for nonenhanced assessment of peripheral artery occlusive disease (PAOD) using contrast-enhanced MRA (CE-MRA) as the reference standard. Materials and methods: Twenty-seven patients (mean age 66.6 {+-} 10.8 years) with PAOD were included in the study. QISS-MRA and CE-MRA of the lower extremity were performed using a 1.5 T MR scanner. In each patient, subjective image quality and the degree of stenosis were evaluated on a four-point scale for 15 predefined arterial segments. Results: Twenty-five of the 27 patients were considered for analysis. Subjective image quality of QISS-MRA was significantly lower for the distal aorta, pelvic arteries, and femoral arteries as compared to CE-MRA (p < 0.01), while no significant difference was found for other vascular segments. The degree of stenosis was overestimated with QISS-MRA in 23 of 365 (6.3%) segments and underestimated in two of 365 (0.5%) segments. As compared to CE-MRA, QISS-MRA had a high sensitivity (98.6%), specificity (96%) as well as positive and negative predictive value (88.7 and 99.6%, respectively) for the detection of significant stenosis ({>=}50%). Conclusion: ECG-gated QISS-MRA is a promising imaging technique for reliable assessment of PAOD without the use of contrast material.

  19. Single-shot characterization of enzymatic reaction constants Km and kcat by an acoustic-driven, bubble-based fast micromixer.

    Science.gov (United States)

    Xie, Yuliang; Ahmed, Daniel; Lapsley, Michael Ian; Lin, Sz-Chin Steven; Nawaz, Ahmad Ahsan; Wang, Lin; Huang, Tony Jun

    2012-09-04

    In this work we present an acoustofluidic approach for rapid, single-shot characterization of enzymatic reaction constants K(m) and k(cat). The acoustofluidic design involves a bubble anchored in a horseshoe structure which can be stimulated by a piezoelectric transducer to generate vortices in the fluid. The enzyme and substrate can thus be mixed rapidly, within 100 ms, by the vortices to yield the product. Enzymatic reaction constants K(m) and k(cat) can then be obtained from the reaction rate curves for different concentrations of substrate while holding the enzyme concentration constant. We studied the enzymatic reaction for β-galactosidase and its substrate (resorufin-β-D-galactopyranoside) and found K(m) and k(cat) to be 333 ± 130 μM and 64 ± 8 s(-1), respectively, which are in agreement with published data. Our approach is valuable for studying the kinetics of high-speed enzymatic reactions and other chemical reactions.

  20. The value of single-shot turbo spin-echo diffusion-weighted MR imaging in the detection of middle ear cholesteatoma

    International Nuclear Information System (INIS)

    De Foer, Bert; Bernaerts, Anja; Maes, Joachim; Deckers, Filip; Pouillon, Marc; Vercruysse, Jean-Philippe; Somers, Thomas; Offeciers, Erwin; Michiels, Johan; Casselman, Jan W.

    2007-01-01

    Single-shot (SS) turbo spin-echo (TSE) diffusion-weighted (DW) magnetic resonance imaging (MRI) is a non echo-planar imaging (EPI) technique recently reported for the evaluation of middle ear cholesteatoma. We prospectively evaluated a SS TSE DW sequence in detecting congenital or acquired middle ear cholesteatoma and evaluated the size of middle ear cholesteatoma detectable with this sequence. The aim of this study was not to differentiate between inflammatory tissue and cholesteatoma using SS TSE DW imaging. A group of 21 patients strongly suspected clinically and/or otoscopically of having a middle ear cholesteatoma without any history of prior surgery were evaluated with late post-gadolinium MRI including this SS TSE DW sequence. A total of 21 middle ear cholesteatomas (5 congenital and 16 acquired) were found at surgery with a size varying between 2 and 19 mm. Hyperintense signal on SS TSE DW imaging compatible with cholesteatoma was found in 19 patients. One patient showed no hyperintensity due to autoevacuation of the cholesteatoma sac into the external auditory canal. Another patient showed no hyperintensity because of motion artifacts. This study shows the high sensitivity of this SS TSE DW sequence in detecting small middle ear cholesteatomas, with a size limit as small as 2 mm. (orig.)

  1. Silicon-Vacancy Spin Qubit in Diamond: A Quantum Memory Exceeding 10 ms with Single-Shot State Readout.

    Science.gov (United States)

    Sukachev, D D; Sipahigil, A; Nguyen, C T; Bhaskar, M K; Evans, R E; Jelezko, F; Lukin, M D

    2017-12-01

    The negatively charged silicon-vacancy (SiV^{-}) color center in diamond has recently emerged as a promising system for quantum photonics. Its symmetry-protected optical transitions enable the creation of indistinguishable emitter arrays and deterministic coupling to nanophotonic devices. Despite this, the longest coherence time associated with its electronic spin achieved to date (∼250  ns) has been limited by coupling to acoustic phonons. We demonstrate coherent control and suppression of phonon-induced dephasing of the SiV^{-} electronic spin coherence by 5 orders of magnitude by operating at temperatures below 500 mK. By aligning the magnetic field along the SiV^{-} symmetry axis, we demonstrate spin-conserving optical transitions and single-shot readout of the SiV^{-} spin with 89% fidelity. Coherent control of the SiV^{-} spin with microwave fields is used to demonstrate a spin coherence time T_{2} of 13 ms and a spin relaxation time T_{1} exceeding 1 s at 100 mK. These results establish the SiV^{-} as a promising solid-state candidate for the realization of quantum networks.

  2. Development of Compton X-ray spectrometer for high energy resolution single-shot high-flux hard X-ray spectroscopy.

    Science.gov (United States)

    Kojima, Sadaoki; Ikenouchi, Takahito; Arikawa, Yasunobu; Sakata, Shohei; Zhang, Zhe; Abe, Yuki; Nakai, Mitsuo; Nishimura, Hiroaki; Shiraga, Hiroyuki; Ozaki, Tetsuo; Miyamoto, Shuji; Yamaguchi, Masashi; Takemoto, Akinori; Fujioka, Shinsuke; Azechi, Hiroshi

    2016-04-01

    Hard X-ray spectroscopy is an essential diagnostics used to understand physical processes that take place in high energy density plasmas produced by intense laser-plasma interactions. A bundle of hard X-ray detectors, of which the responses have different energy thresholds, is used as a conventional single-shot spectrometer for high-flux (>10(13) photons/shot) hard X-rays. However, high energy resolution (Δhv/hv spectrometer because its energy resolution is limited by energy differences between the response thresholds. Experimental demonstration of a Compton X-ray spectrometer has already been performed for obtaining higher energy resolution than that of DET spectrometers. In this paper, we describe design details of the Compton X-ray spectrometer, especially dependence of energy resolution and absolute response on photon-electron converter design and its background reduction scheme, and also its application to the laser-plasma interaction experiment. The developed spectrometer was used for spectroscopy of bremsstrahlung X-rays generated by intense laser-plasma interactions using a 200 μm thickness SiO2 converter. The X-ray spectrum obtained with the Compton X-ray spectrometer is consistent with that obtained with a DET X-ray spectrometer, furthermore higher certainly of a spectral intensity is obtained with the Compton X-ray spectrometer than that with the DET X-ray spectrometer in the photon energy range above 5 MeV.

  3. Readout-Segmented Echo-Planar Imaging in Diffusion-Weighted MR Imaging in Breast Cancer: Comparison with Single-Shot Echo-Planar Imaging in Image Quality

    International Nuclear Information System (INIS)

    Kim, Yun Ju; Kim, Sung Hun; Kang, Bong Joo; Park, Chang Suk; Kim, Hyeon Sook; Son, Yo Han; Porter, David Andrew; Song, Byung Joo

    2014-01-01

    The purpose of this study was to compare the image quality of standard single-shot echo-planar imaging (ss-EPI) and that of readout-segmented EPI (rs-EPI) in patients with breast cancer. Seventy-one patients with 74 breast cancers underwent both ss-EPI and rs-EPI. For qualitative comparison of image quality, three readers independently assessed the two sets of diffusion-weighted (DW) images. To evaluate geometric distortion, a comparison was made between lesion lengths derived from contrast enhanced MR (CE-MR) images and those obtained from the corresponding DW images. For assessment of image parameters, signal-to-noise ratio (SNR), lesion contrast, and contrast-to-noise ratio (CNR) were calculated. The rs-EPI was superior to ss-EPI in most criteria regarding the qualitative image quality. Anatomical structure distinction, delineation of the lesion, ghosting artifact, and overall image quality were significantly better in rs-EPI. Regarding the geometric distortion, lesion length on ss-EPI was significantly different from that of CE-MR, whereas there were no significant differences between CE-MR and rs-EPI. The rs-EPI was superior to ss-EPI in SNR and CNR. Readout-segmented EPI is superior to ss-EPI in the aspect of image quality in DW MR imaging of the breast

  4. Nonenhanced ECG-gated quiescent-interval single-shot MRA (QISS-MRA) of the lower extremities: Comparison with contrast-enhanced MRA

    International Nuclear Information System (INIS)

    Klasen, J.; Blondin, D.; Schmitt, P.; Bi, X.; Sansone, R.; Wittsack, H.-J.; Kröpil, P.; Quentin, M.; Kuhlemann, J.; Miese, F.; Heiss, C.; Kelm, M.; Antoch, G.; Lanzman, R.S.

    2012-01-01

    Aim: To evaluate electrocardiogram (ECG)-gated quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) for nonenhanced assessment of peripheral artery occlusive disease (PAOD) using contrast-enhanced MRA (CE-MRA) as the reference standard. Materials and methods: Twenty-seven patients (mean age 66.6 ± 10.8 years) with PAOD were included in the study. QISS-MRA and CE-MRA of the lower extremity were performed using a 1.5 T MR scanner. In each patient, subjective image quality and the degree of stenosis were evaluated on a four-point scale for 15 predefined arterial segments. Results: Twenty-five of the 27 patients were considered for analysis. Subjective image quality of QISS-MRA was significantly lower for the distal aorta, pelvic arteries, and femoral arteries as compared to CE-MRA (p < 0.01), while no significant difference was found for other vascular segments. The degree of stenosis was overestimated with QISS-MRA in 23 of 365 (6.3%) segments and underestimated in two of 365 (0.5%) segments. As compared to CE-MRA, QISS-MRA had a high sensitivity (98.6%), specificity (96%) as well as positive and negative predictive value (88.7 and 99.6%, respectively) for the detection of significant stenosis (≥50%). Conclusion: ECG-gated QISS-MRA is a promising imaging technique for reliable assessment of PAOD without the use of contrast material.

  5. Non-contrast-enhanced MR angiography in critical limb ischemia: performance of quiescent-interval single-shot (QISS) and TSE-based subtraction techniques

    International Nuclear Information System (INIS)

    Altaha, Mustafa A.; Jaskolka, Jeffrey D.; Tan, Kongteng; Menezes, Ravi J.; Rick, Manuela; Schmitt, Peter; Wintersperger, Bernd J.

    2017-01-01

    The aim of this study was to evaluate diagnostic performance of non-contrast-enhanced 2D quiescent-interval single-shot (QISS) and 3D turbo spin-echo (TSE)-based subtraction magnetic resonance angiography (MRA) in the assessment of peripheral arteries in patients with critical limb ischemia (CLI). Nineteen consecutive patients (74 % male, 72.8 ± 9.9 years) with CLI underwent 2D QISS and 3D TSE-based subtraction MRA at 1.5 T. Axial-overlapping QISS MRA (3 mm/2 mm; 1 x 1 mm 2 ) covered from the toes to the aortic bifurcation while coronal 3D TSE-based subtraction MRA (1.3 x 1.2 x 1.3 mm 3 ) was restricted to the calf only. MRA data sets (two readers) were evaluated for stenosis (≥50 %) and image quality. Results were compared with digital subtraction angiography (DSA). Two hundred and sixty-seven (267) segments were available for MRA-DSA comparison, with a prevalence of stenosis ≥50 % of 41.9 %. QISS MRA was rated as good to excellent in 79.5-96.0 % of segments without any nondiagnostic segments; 89.8-96.1 % of segments in 3D TSE-based subtraction MRA were rated as nondiagnostic or poor. QISS MRA sensitivities and specificities (segmental) were 92 % and 95 %, respectively, for reader one and 81-97 % for reader two. Due to poor image quality of 3D TSE-based subtraction MRA, diagnostic performance measures were not calculated. QISS MRA demonstrates excellent diagnostic performance and higher robustness than 3D TSE-based subtraction MRA in the challenging patient population with CLI. (orig.)

  6. Diffusion tensor trace mapping in normal adult brain using single-shot EPI technique: A methodological study of the aging brain

    International Nuclear Information System (INIS)

    Chen, Z.G.; Hindmarsh, T.; Li, T.Q.

    2001-01-01

    Purpose: To quantify age-related changes of the average diffusion coefficient value in normal adult brain using orientation-independent diffusion tensor trace mapping and to address the methodological influences on diffusion quantification. Material and Methods: Fifty-four normal subjects (aged 20-79 years) were studied on a 1.5-T whole-body MR medical unit using a diffusion-weighted single-shot echo-planar imaging technique. Orientation-independent diffusion tensor trace maps were constructed for each subject using diffusion-weighted MR measurements in four different directions using a tetrahedral gradient combination pattern. The global average (including cerebral spinal fluid) and the tissue average of diffusion coefficients in adult brains were determined by analyzing the diffusion coefficient distribution histogram for the entire brain. Methodological influences on the measured diffusion coefficient were also investigated by comparing the results obtained using different experimental settings. Results: Both global and tissue averages of the diffusion coefficient are significantly correlated with age (p<0.03). The global average of the diffusion coefficient increases 3% per decade after the age of 40, whereas the increase in the tissue average of diffusion coefficient is about 1% per decade. Experimental settings for self-diffusion measurements, such as data acquisition methods and number of b-values, can slightly influence the statistical distribution histogram of the diffusion tensor trace and its average value. Conclusion: Increased average diffusion coefficient in adult brains with aging are consistent with findings regarding structural changes in the brain that have been associated with aging. The study also demonstrates that it is desirable to use the same experimental parameters for diffusion coefficient quantification when comparing between different subjects and groups of interest

  7. Pin-hole array production and detailed data analysis for advanced single-shot X-ray imaging of laboratory plasmas

    Science.gov (United States)

    Levato, T.; Labate, L.; Pathak, N. C.; Cecchetti, C.; Koester, P.; Di Fabrizio, E.; Delogu, P.; Giulietti, A.; Giulietti, D.; Gizzi, L. A.

    2010-11-01

    Laser produced plasmas offer the unique opportunity to investigate physical mechanisms working at extremely high field in pulsed regime [1] (Gizzi et al., 2009). Future large scale infrastructure like HiPER and ELI may open new frontiers of knowledge in this way. Technologies needed for improving diagnostic in this field have a strong impact on a wide range of multi-disciplinary applications as for compact plasma-based accelerators [1,2] (Gizzi et al., 2009; Betti et al., 2009) laser fusion oriented experiments, three-dimensional microscopy and lithography. As an example the X-ray imaging, being a powerful diagnostic tool for deep investigation on different variety of laser produced plasma, has obtained a grooving effort in recent years. Large scale facilities working in single-pulse regime for laser fusion oriented experiments have evidenced the necessity to obtain spectrally resolved X-ray images of produced plasmas in a single shot. By combining the charge coupled devices (CCD) based single-photon detection technique with a pin-hole array (PHA) a new diagnostic technique was developed, as shown in recent experiments related to the European HiPER project [3] (Labate et al., 2009). Here we qualitatively describe the PHA production process on a heavy metal substrate by means of SEM images that show an internal diameter on the micrometer scale and an aspect ratio of about 20. The characterization of the X-ray contrast up to 90 keV is presented. The data analysis of the X-ray photons interaction on CCD, for spectrum reconstruction up to high energy, is described [4] (Levato et al., 2008).

  8. Pin-hole array production and detailed data analysis for advanced single-shot X-ray imaging of laboratory plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Levato, T., E-mail: tadzio.levato@lnf.infn.i [FLAME, Laboratori Nazionali di Frascati (LNF), Via E. Fermi 40, 00044 Frascati (Italy); Labate, L.; Pathak, N.C.; Cecchetti, C.; Koester, P. [ILIL, Consiglio Nazionale delle Ricerche (CNR), Pisa (Italy); Di Fabrizio, E. [BIONEM, Campus Magna Graecia University of Catanzaro (UMG) (Italy); Delogu, P. [University of Pisa, Department of Physics (Italy); Giulietti, A. [ILIL, Consiglio Nazionale delle Ricerche (CNR), Pisa (Italy); Giulietti, D. [University of Pisa, Department of Physics (Italy); Gizzi, L.A. [ILIL, Consiglio Nazionale delle Ricerche (CNR), Pisa (Italy)

    2010-11-11

    Laser produced plasmas offer the unique opportunity to investigate physical mechanisms working at extremely high field in pulsed regime (Gizzi et al., 2009). Future large scale infrastructure like HiPER and ELI may open new frontiers of knowledge in this way. Technologies needed for improving diagnostic in this field have a strong impact on a wide range of multi-disciplinary applications as for compact plasma-based accelerators (Gizzi et al., 2009; Betti et al., 2009) laser fusion oriented experiments, three-dimensional microscopy and lithography. As an example the X-ray imaging, being a powerful diagnostic tool for deep investigation on different variety of laser produced plasma, has obtained a grooving effort in recent years. Large scale facilities working in single-pulse regime for laser fusion oriented experiments have evidenced the necessity to obtain spectrally resolved X-ray images of produced plasmas in a single shot. By combining the charge coupled devices (CCD) based single-photon detection technique with a pin-hole array (PHA) a new diagnostic technique was developed, as shown in recent experiments related to the European HiPER project (Labate et al., 2009). Here we qualitatively describe the PHA production process on a heavy metal substrate by means of SEM images that show an internal diameter on the micrometer scale and an aspect ratio of about 20. The characterization of the X-ray contrast up to 90 keV is presented. The data analysis of the X-ray photons interaction on CCD, for spectrum reconstruction up to high energy, is described (Levato et al., 2008).

  9. Faster pediatric 3-T abdominal magnetic resonance imaging: comparison between conventional and variable refocusing flip-angle single-shot fast spin-echo sequences.

    Science.gov (United States)

    Ruangwattanapaisarn, Nichanan; Loening, Andreas M; Saranathan, Manojkumar; Litwiller, Daniel V; Vasanawala, Shreyas S

    2015-06-01

    Single-shot fast spin echo (SSFSE) is particularly appealing in pediatric patients because of its motion robustness. However radiofrequency energy deposition at 3 tesla forces long pauses between slices, leading to longer scans, longer breath-holds and more between-slice motion. We sought to learn whether modulation of the SSFSE refocusing flip-angle train could reduce radiofrequency energy deposition without degrading image quality, thereby reducing inter-slice pauses and overall scan times. We modulated the refocusing flip-angle train for SSFSE to minimize energy deposition while minimizing blurring and motion-related signal loss. In a cohort of 50 consecutive patients (25 boys, mean age 5.5 years, range 1 month to 17 years) referred for abdominal MRI we obtained standard SSFSE and variable refocusing flip-angle (vrfSSFSE) images and recorded sequence scan times. Two readers independently scored the images in blinded, randomized order for noise, tissue contrast, sharpness, artifacts and left lobe hepatic signal uniformity on a four-point scale. The null hypothesis of no difference between SSFSE and vrfSSFSE image-quality was assessed with a Mann-Whitney U test, and the null hypothesis of no scan time difference was assessed with the paired t-test. SSFSE and vrfSSFSE mean acquisition times were 54.3 and 26.2 s, respectively (P-value <0.0001). For each reader, SSFSE and vrfSSFSE noise, tissue contrast, sharpness and artifacts were not significantly different (P-values 0.18-0.86). However, SSFSE had better left lobe hepatic signal uniformity (P < 0.01, both readers). vrfSSFSE is twice as fast as SSFSE, with equivalent image quality with the exception of left hepatic lobe signal heterogeneity.

  10. Faster pediatric 3-T abdominal magnetic resonance imaging: comparison between conventional and variable refocusing flip-angle single-shot fast spin-echo sequences

    International Nuclear Information System (INIS)

    Ruangwattanapaisarn, Nichanan; Loening, Andreas M.; Saranathan, Manojkumar; Vasanawala, Shreyas S.; Litwiller, Daniel V.

    2015-01-01

    Single-shot fast spin echo (SSFSE) is particularly appealing in pediatric patients because of its motion robustness. However radiofrequency energy deposition at 3 tesla forces long pauses between slices, leading to longer scans, longer breath-holds and more between-slice motion. We sought to learn whether modulation of the SSFSE refocusing flip-angle train could reduce radiofrequency energy deposition without degrading image quality, thereby reducing inter-slice pauses and overall scan times. We modulated the refocusing flip-angle train for SSFSE to minimize energy deposition while minimizing blurring and motion-related signal loss. In a cohort of 50 consecutive patients (25 boys, mean age 5.5 years, range 1 month to 17 years) referred for abdominal MRI we obtained standard SSFSE and variable refocusing flip-angle (vrfSSFSE) images and recorded sequence scan times. Two readers independently scored the images in blinded, randomized order for noise, tissue contrast, sharpness, artifacts and left lobe hepatic signal uniformity on a four-point scale. The null hypothesis of no difference between SSFSE and vrfSSFSE image-quality was assessed with a Mann-Whitney U test, and the null hypothesis of no scan time difference was assessed with the paired t-test. SSFSE and vrfSSFSE mean acquisition times were 54.3 and 26.2 s, respectively (P-value <0.0001). For each reader, SSFSE and vrfSSFSE noise, tissue contrast, sharpness and artifacts were not significantly different (P-values 0.18-0.86). However, SSFSE had better left lobe hepatic signal uniformity (P < 0.01, both readers). vrfSSFSE is twice as fast as SSFSE, with equivalent image quality with the exception of left hepatic lobe signal heterogeneity. (orig.)

  11. Comparison of respiratory-triggered 3-D fast spin-echo and single-shot fast spin-echo radial slab MR cholangiopancreatography images in children

    International Nuclear Information System (INIS)

    Chavhan, Govind B.; Almehdar, Abeer; Gupta, Sumeet; Moineddin, Rahim; Babyn, Paul S.

    2013-01-01

    The two most commonly performed magnetic resonance cholangiopancreatography (MRCP) sequences, 3-D fast spin-echo (3-D FSE) and single-shot fast spin-echo radial slabs (radial slabs), have not been compared in children. The purpose of this study was to compare 3-D FSE and radial slabs MRCP sequences on a 3-T scanner to determine their ability to show various segments of pancreaticobiliary tree and presence of artifacts in children. We reviewed 79 consecutive MRCPs performed in 74 children on a 3-T scanner. We noted visibility of major ducts on 3-D FSE and radial slabs. We noted the order of branching of ducts in the right and left hepatic ducts and the degree of visibility of the pancreatic duct. Statistical analysis was performed using McNemar and signed rank tests. There was no significant difference in the visibility of major bile ducts and the order of branching in the right hepatic lobe between sequences. A higher order of branching in the left lobe was seen on radial slabs than 3-D FSE (mean order of branching 2.82 versus 2.27; P-value = 0.0002). The visibility of pancreatic duct was better on radial slabs as compared to 3-D FSE (mean value of 1.53 vs. 0.90; P-value < 0.0001). 3-D FSE sequence was artifact-free in 25/79 (31.6%) MRCP exams as compared to radial slabs, which were artifact-free in 18/79 (22.8%) MRCP exams (P-value = 0.0001). There is no significant difference in the visibility of major bile ducts between 3-D FSE and radial slab MRCP sequences at 3-T in children. However, radial slab MRCP shows a higher order of branching in the left hepatic lobe and superior visibility of the pancreatic duct than 3-D FSE. (orig.)

  12. Faster pediatric 3-T abdominal magnetic resonance imaging: comparison between conventional and variable refocusing flip-angle single-shot fast spin-echo sequences

    Energy Technology Data Exchange (ETDEWEB)

    Ruangwattanapaisarn, Nichanan [Mahidol University, Department of Diagnostic and Therapeutic Radiology, Ramathibodi Hospital, Bangkok (Thailand); Stanford University, LPCH Department of Radiology, Stanford, CA (United States); Loening, Andreas M.; Saranathan, Manojkumar; Vasanawala, Shreyas S. [Stanford University, LPCH Department of Radiology, Stanford, CA (United States); Litwiller, Daniel V. [GE Healthcare, Rochester, MN (United States)

    2015-06-15

    Single-shot fast spin echo (SSFSE) is particularly appealing in pediatric patients because of its motion robustness. However radiofrequency energy deposition at 3 tesla forces long pauses between slices, leading to longer scans, longer breath-holds and more between-slice motion. We sought to learn whether modulation of the SSFSE refocusing flip-angle train could reduce radiofrequency energy deposition without degrading image quality, thereby reducing inter-slice pauses and overall scan times. We modulated the refocusing flip-angle train for SSFSE to minimize energy deposition while minimizing blurring and motion-related signal loss. In a cohort of 50 consecutive patients (25 boys, mean age 5.5 years, range 1 month to 17 years) referred for abdominal MRI we obtained standard SSFSE and variable refocusing flip-angle (vrfSSFSE) images and recorded sequence scan times. Two readers independently scored the images in blinded, randomized order for noise, tissue contrast, sharpness, artifacts and left lobe hepatic signal uniformity on a four-point scale. The null hypothesis of no difference between SSFSE and vrfSSFSE image-quality was assessed with a Mann-Whitney U test, and the null hypothesis of no scan time difference was assessed with the paired t-test. SSFSE and vrfSSFSE mean acquisition times were 54.3 and 26.2 s, respectively (P-value <0.0001). For each reader, SSFSE and vrfSSFSE noise, tissue contrast, sharpness and artifacts were not significantly different (P-values 0.18-0.86). However, SSFSE had better left lobe hepatic signal uniformity (P < 0.01, both readers). vrfSSFSE is twice as fast as SSFSE, with equivalent image quality with the exception of left hepatic lobe signal heterogeneity. (orig.)

  13. Non-contrast-enhanced MR angiography in critical limb ischemia: performance of quiescent-interval single-shot (QISS) and TSE-based subtraction techniques

    Energy Technology Data Exchange (ETDEWEB)

    Altaha, Mustafa A. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); Jaskolka, Jeffrey D.; Tan, Kongteng; Menezes, Ravi J. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); University of Toronto, Department of Medical Imaging, Toronto, Ontario (Canada); Rick, Manuela; Schmitt, Peter [Siemens Healthcare, Erlangen (Germany); Wintersperger, Bernd J. [University Health Network, Department of Medical Imaging, Peter Munk Cardiac Centre, Toronto, Ontario (Canada); University of Toronto, Department of Medical Imaging, Toronto, Ontario (Canada); Toronto General Hospital, Department of Medical Imaging, Toronto, Ontario (Canada)

    2017-03-15

    The aim of this study was to evaluate diagnostic performance of non-contrast-enhanced 2D quiescent-interval single-shot (QISS) and 3D turbo spin-echo (TSE)-based subtraction magnetic resonance angiography (MRA) in the assessment of peripheral arteries in patients with critical limb ischemia (CLI). Nineteen consecutive patients (74 % male, 72.8 ± 9.9 years) with CLI underwent 2D QISS and 3D TSE-based subtraction MRA at 1.5 T. Axial-overlapping QISS MRA (3 mm/2 mm; 1 x 1 mm{sup 2}) covered from the toes to the aortic bifurcation while coronal 3D TSE-based subtraction MRA (1.3 x 1.2 x 1.3 mm{sup 3}) was restricted to the calf only. MRA data sets (two readers) were evaluated for stenosis (≥50 %) and image quality. Results were compared with digital subtraction angiography (DSA). Two hundred and sixty-seven (267) segments were available for MRA-DSA comparison, with a prevalence of stenosis ≥50 % of 41.9 %. QISS MRA was rated as good to excellent in 79.5-96.0 % of segments without any nondiagnostic segments; 89.8-96.1 % of segments in 3D TSE-based subtraction MRA were rated as nondiagnostic or poor. QISS MRA sensitivities and specificities (segmental) were 92 % and 95 %, respectively, for reader one and 81-97 % for reader two. Due to poor image quality of 3D TSE-based subtraction MRA, diagnostic performance measures were not calculated. QISS MRA demonstrates excellent diagnostic performance and higher robustness than 3D TSE-based subtraction MRA in the challenging patient population with CLI. (orig.)

  14. Highly Resolved Mg/Ca Depth Profiles of Planktic Foraminifer test Walls Using Single shot Measurements of fs-LA-ICPMS

    Science.gov (United States)

    Jochum, K. P.; Schiebel, R.; Stoll, B.; Weis, U.; Haug, G. H.

    2017-12-01

    Foraminifers are sensitive archives of changes in climate and marine environment. It has been shown that the Mg/Ca signal is a suitable proxy of seawater temperature, because the incorporation of Mg depends on ambient water temperature. In contrast to most former studies, where this ratio is determined by solution-based bulk analysis of 20 - 30 specimens, we have investigated Mg/Ca in single specimens and single chambers at high resolution. A new fs-200 nm-LA-ICPMS technique was developed for the µm-sized layered calcite shells. To generate depth profiles with a resolution of about 50 nm/shot, we chose a low fluence of about 0.3 Jcm-2 and performed single shot measurements of the double charged 44Ca++ and the single charged 25Mg+ ions together. Precision (RSD) of the Mg/Ca data is about 5 %. Calibration was performed with the carbonate reference material MACS-3 from the USGS. Our results for different species from the Arabian Sea and Caribbean Sea demonstrate that Mg/Ca of different chambers vary and indicate that the foraminifer individuals built their chambers in different water depths and/or experienced seasonal changes in seawater temperature caused, for example, by upwelling (cold) versus stratified (warm) conditions. Typically, the Mg/Ca ratios of the final two chambers of the planktic foraminifer Globorotalia menardii from a sediment core of the Arabian Sea differ by about 5 mmol/mol from earlier chambers (2 mmol/mol) corresponding to seawater temperatures of 28 °C and 18 °C, respectively. In addition, mass fractions of other elements like Sr, Mn, Fe, Ba, and U have been determined with fs-LA-ICPMS using fast line scans, and thus provide further insights in the ecology of foraminifers.

  15. Development of Compton X-ray spectrometer for high energy resolution single-shot high-flux hard X-ray spectroscopy

    International Nuclear Information System (INIS)

    Kojima, Sadaoki; Ikenouchi, Takahito; Arikawa, Yasunobu; Sakata, Shohei; Zhang, Zhe; Abe, Yuki; Nakai, Mitsuo; Nishimura, Hiroaki; Shiraga, Hiroyuki; Fujioka, Shinsuke; Azechi, Hiroshi; Ozaki, Tetsuo; Miyamoto, Shuji; Yamaguchi, Masashi; Takemoto, Akinori

    2016-01-01

    Hard X-ray spectroscopy is an essential diagnostics used to understand physical processes that take place in high energy density plasmas produced by intense laser-plasma interactions. A bundle of hard X-ray detectors, of which the responses have different energy thresholds, is used as a conventional single-shot spectrometer for high-flux (>10 13 photons/shot) hard X-rays. However, high energy resolution (Δhv/hv < 0.1) is not achievable with a differential energy threshold (DET) X-ray spectrometer because its energy resolution is limited by energy differences between the response thresholds. Experimental demonstration of a Compton X-ray spectrometer has already been performed for obtaining higher energy resolution than that of DET spectrometers. In this paper, we describe design details of the Compton X-ray spectrometer, especially dependence of energy resolution and absolute response on photon-electron converter design and its background reduction scheme, and also its application to the laser-plasma interaction experiment. The developed spectrometer was used for spectroscopy of bremsstrahlung X-rays generated by intense laser-plasma interactions using a 200 μm thickness SiO 2 converter. The X-ray spectrum obtained with the Compton X-ray spectrometer is consistent with that obtained with a DET X-ray spectrometer, furthermore higher certainly of a spectral intensity is obtained with the Compton X-ray spectrometer than that with the DET X-ray spectrometer in the photon energy range above 5 MeV.

  16. Non-chromatographic preparation of a bacterially produced single-shot modular virus-like particle capsomere vaccine for avian influenza.

    Science.gov (United States)

    Wibowo, Nani; Wu, Yang; Fan, Yuanyuan; Meers, Joanne; Lua, Linda H L; Middelberg, Anton P J

    2015-11-04

    Highly pathogenic avian influenza (HPAI) causes significant economic loss, reduced food security and poses an ongoing pandemic threat. Poultry vaccination significantly decreases these problems and recognizes that the health of humans, animals and ecosystems are connected. Low-cost manufacture of poultry vaccine matched quickly to the ever-changing circulating strain is needed for effective vaccination. Here, we re-engineered the process to manufacture bacterially synthesized modular capsomere comprising influenza M2e, previously shown to confer complete protection in challenged mice, for application in poultry. Modular capsomere was prepared using a simplified non-chromatographic salting-out precipitation method and its immunogenicity tested in vivo in poultry. Modular capsomere crudely purified by precipitation (pCapM2e) contained more contaminants than equivalent product purified by chromatography (cCapM2e). Unadjuvanted pCapM2e containing 80 EU of endotoxin per dose was inferior to highly purified and adjuvanted cCapM2e (2 EU per dose). However, addition of adjuvant to pCapM2e resulting in high immunogenicity after only a single dose of vaccination, yet without any local adverse reaction. This finding suggests a strong synergy between adjuvant, antigen and contaminants, and the possible existence of a "Goldilocks" level of contaminants, where high immunogenicity and low reactogenicity can be obtained in a single-shot vaccination. The simplified process offers potential cost and speed advantages to address the needs in influenza poultry vaccination in low-cost veterinary markets. Copyright © 2015 Elsevier Ltd. All rights reserved.

  17. Image quality assessment of single-shot turbo spin echo diffusion-weighted imaging with parallel imaging technique: a phantom study.

    Science.gov (United States)

    Yoshida, Tsukasa; Urikura, Atsushi; Shirata, Kensei; Nakaya, Yoshihiro; Terashima, Shingo; Hosokawa, Yoichiro

    2016-09-01

    This study aimed to evaluate the image quality and apparent diffusion coefficient (ADC) values of single-shot turbo spin echo (TSE) diffusion-weighted (DW) images obtained using a parallel imaging (PI) technique. All measurements were performed on a 3.0-T whole-body MRI system and 32-channel phased-array coil. Signal-to-noise ratio (SNR) and ADC values were measured with a DW imaging (DWI) phantom comprising granulated sugar and agar. The SNRs were calculated using a subtraction method and compared among TSE-DW images at acceleration factors (AFs) of 1-4. Image blur was visually assessed on TSE-DW images of a pin phantom at AFs of 1-4. The ADC values were calculated using DW images with b = 0 and 1000 s mm(-2). The ADC values of TSE-DW images and echo-planar imaging EPI-DW images were compared. The SNRs decreased as AFs increased, despite selecting the shortest echo time. A lower AF caused increased image blur in the phase-encoding direction. The ADC values of TSE-DWI tended to be lower than those of EPI-DWI, and AFs of 3 and 4 yielded variable ADC values on TSE-DW images. TSE-DWI with an AF of 3 or 4 yielded reduced SNRs; in addition, the image noise and artefacts associated with PI technique may have affected ADC measurements, despite improving image blur in the phase-encoding direction. Optimizing the imaging parameters of TSE-DWI is useful for providing good image quality and accurate ADC measurements.

  18. ECG-gated quiescent-interval single-shot MR angiography of the lower extremities: Initial experience at 3 T

    International Nuclear Information System (INIS)

    Knobloch, G.; Gielen, M.; Lauff, M.-T.; Romano, V.C.; Schmitt, P.; Rick, M.; Kröncke, T.J.; Huppertz, A.; Hamm, B.; Wagner, M.

    2014-01-01

    Aim: To evaluate the feasibility of unenhanced electrocardiography (ECG)-gated quiescent-interval single-shot magnetic resonance angiography (QISS-MRA) of the lower extremities at 3 T. Materials and methods: Twenty-five patients with known or suspected peripheral arterial disease underwent ECG-gated QISS-MRA and contrast-enhanced MRA (CE-MRA) at 3 T. Two independent readers performed a per-segment evaluation of the MRA datasets. Image quality was rated on a four-point scale (1 = excellent to 4 = non-diagnostic; presented as medians with interquartile range). Diagnostic performance of QISS-MRA was evaluated using CE-MRA as the reference standard. Results: QISS-MRA and CE-MRA of all patients were considered for analysis, resulting in 807 evaluated vessel segments for each MRA technique. Readers 1 and 2 rated image quality of QISS-MRA as diagnostic in 97.3% and 97% of the vessel segments, respectively. CE-MRA was rated diagnostic in all vessel segments. Image quality of the proximal vessel segments, including the infrarenal aorta, iliac arteries, and common femoral artery, was significantly lower on QISS-MRA compared to CE-MRA [image quality score across readers: 2 (1,3) versus 1 (1,1) p < 0.001]. In the more distal vessel segments, image quality of QISS-MRA was excellent and showed no significant difference compared to CE-MRA [image quality score across readers: 1 (1,1) versus 1 (1,1) p = 0.036]. Diagnostic performance of QISS-MRA was as follows (across readers): sensitivity: 87.5% (95% CI: 80.2–92.4%); specificity: 96.1% (95% CI: 93.6–97.6%); diagnostic accuracy: 94.9% (95% CI: 92.6–96.5%). Conclusions: QISS-MRA of the lower extremities is feasible at 3 T and provides high image quality, especially in the distal vessel segments

  19. Intra-Articular, Single-Shot Hylan G-F 20 Hyaluronic Acid Injection Compared with Corticosteroid in Knee Osteoarthritis: A Double-Blind, Randomized Controlled Trial.

    Science.gov (United States)

    Tammachote, Nattapol; Kanitnate, Supakit; Yakumpor, Thanasak; Panichkul, Phonthakorn

    2016-06-01

    The treatment of knee osteoarthritis with hyaluronic acid or corticosteroid injection has been widely used. The purpose of this study was to compare the efficacy of hyaluronic acid (hylan G-F 20) with triamcinolone acetonide as a single intra-articular injection for knee osteoarthritis. This study was a prospective, randomized, double-blind clinical trial. Participants with symptomatic knee osteoarthritis were recruited. They were randomized to receive a single-shot, intra-articular injection of either 6 mL of hylan G-F 20 or 6 mL of a solution comprising 1 mL of 40-mg triamcinolone acetonide and 5 mL of 1% lidocaine with epinephrine. The primary outcomes were knee pain severity, knee function, and range of motion at 6 months. Ninety-nine patients were assessed before injection and underwent a 6-month follow-up. Patients and evaluators were blinded. Multilevel regression models were used to estimate differences between the groups. At the 6-month follow-up, compared with patients who took hylan G-F 20, patients who took triamcinolone acetonide had similar improvement in knee pain, knee function, and range of motion. The difference in mean outcome scores between groups was, with regard to knee pain, a visual analog scale (VAS) score of 3 points (95% confidence interval [95% CI], -6 to 11 points); with regard to knee function, a modified Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) score of 0 points (95% CI, -8 to 6 points); and, with regard to range of motion, flexion of -1° (95% CI, -5° to 2°) and extension of 0° (95% CI, -0.5° to 0.5°). However, patients who took triamcinolone acetonide had better pain improvement from 24 hours until 1 week after injection; the mean difference between groups with regard to the VAS score was 12 points (95% CI, 5 to 20 points; p = 0.002) at 24 hours and 9 points (95% CI, 1 to 15 points; p = 0.018) at 1 week. At 2 weeks after injection, patients who took triamcinolone acetonide also had better knee

  20. Small Field-of-view single-shot EPI-DWI of the prostate: Evaluation of spatially-tailored two-dimensional radiofrequency excitation pulses.

    Science.gov (United States)

    Attenberger, Ulrike I; Rathmann, Nils; Sertdemir, Metin; Riffel, Philipp; Weidner, Anja; Kannengiesser, Stefan; Morelli, John N; Schoenberg, Stefan O; Hausmann, Daniel

    2016-06-01

    Spatially-tailored (RF) excitation pulses in echo-planar imaging (EPI), combined with a decreased FOV in the phase-encoding direction, enable a reduction of k-space acquisition lines, which shortens the echo train length (ETL) and reduces susceptibility artifacts. The purpose of this study was to evaluate the image quality of a zoomed EPI (z-EPI) sequence in diffusion-weighted imaging (DWI) of the prostate in comparison to a conventional single-shot EPI using single-channel (c-EPI1) and multi-channel (c-EPI2) RF excitation, with and without use of an endorectal coil. 33 consecutive patients (mean age: 61 +/- 9 years; mean PSA: 8.67±6.23 ng/ml) with examinations between 10/2012 and 02/2014 were analyzed in this retrospective study. In 26 of 33 patients the initial multiparametric (mp)-MRI was performed on a whole-body 3T scanner (Magnetom Trio, Siemens, Erlangen, Germany) using an endorectal coil (c (conventional)-EPI1). Zoomed-EPI (Z-EPI) examinations of these patients and a complete mp-MRI protocol including c-EPI2 of 7 additional patients were carried out on another 3T wb MR scanner with two-channel dynamic parallel transmit capability (Magnetom Skyra with TimTX TrueShape, Siemens). For z-EPI, the one-dimensional spatially selective RF excitation pulse was replaced by a two-dimensional RF pulse. Degree of image blur and susceptibility artifacts (0=not present to 3= non-diagnostic), maximum image distortion (mm), apparent diffusion coefficient (ADC) values, as well as overall scan preference were evaluated. SNR maps were generated to compare c-EPI2 and z-EPI. Overall image quality of z-EPI was preferred by both readers in all examinations with a single exception. Susceptibility artifacts were rated significantly lower on z-EPI compared to both other methods (z-EPI vs c-EPI1: p<0.01; z-EPI vs c-EPI2: p<0.01) as well as image blur (z-EPI vs c-EPI1: p<0.01; z-EPI vs c-EPI2: p<0.01). Image distortion was not statistically significantly reduced with z-EPI (z-EPI vs c

  1. Blind Source Separation of Event-Related EEG/MEG.

    Science.gov (United States)

    Metsomaa, Johanna; Sarvas, Jukka; Ilmoniemi, Risto Juhani

    2017-09-01

    Blind source separation (BSS) can be used to decompose complex electroencephalography (EEG) or magnetoencephalography data into simpler components based on statistical assumptions without using a physical model. Applications include brain-computer interfaces, artifact removal, and identifying parallel neural processes. We wish to address the issue of applying BSS to event-related responses, which is challenging because of nonstationary data. We introduce a new BSS approach called momentary-uncorrelated component analysis (MUCA), which is tailored for event-related multitrial data. The method is based on approximate joint diagonalization of multiple covariance matrices estimated from the data at separate latencies. We further show how to extend the methodology for autocovariance matrices and how to apply BSS methods suitable for piecewise stationary data to event-related responses. We compared several BSS approaches by using simulated EEG as well as measured somatosensory and transcranial magnetic stimulation (TMS) evoked EEG. Among the compared methods, MUCA was the most tolerant one to noise, TMS artifacts, and other challenges in the data. With measured somatosensory data, over half of the estimated components were found to be similar by MUCA and independent component analysis. MUCA was also stable when tested with several input datasets. MUCA is based on simple assumptions, and the results suggest that MUCA is robust with nonideal data. Event-related responses and BSS are valuable and popular tools in neuroscience. Correctly designed BSS is an efficient way of identifying artifactual and neural processes from nonstationary event-related data.

  2. Intracerebral Event-related Potentials to Subthreshold Target Stimuli

    Czech Academy of Sciences Publication Activity Database

    Brázdil, M.; Rektor, I.; Daniel, P.; Dufek, M.; Jurák, Pavel

    2001-01-01

    Roč. 112, č. 4 (2001), s. 650-661 ISSN 1388-2457 R&D Projects: GA ČR GA309/98/0490 Institutional research plan: CEZ:AV0Z2065902 Keywords : event-related potentials * intracerebral recordings * oddball paradigm Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery Impact factor: 1.922, year: 2001

  3. Event-Related Potentials and the Stroop Effect.

    Science.gov (United States)

    Sahinoglu, Babur; Dogan, Gamze

    2016-02-01

    In this manuscript, the researches on the Event-Related Potentials (ERP) elicited by the standard Stroop effect were reviewed. For the sake of clarity, only the parts of the manuscripts that reported the standard Stroop effect - ERPs relation were taken into consideration.

  4. Event-Related Potentials and the Stroop Effect

    OpenAIRE

    Sahinoglu, Babur; Dogan, Gamze

    2016-01-01

    In this manuscript, the researches on the Event-Related Potentials (ERP) elicited by the standard Stroop effect were reviewed. For the sake of clarity, only the parts of the manuscripts that reported the standard Stroop effect - ERPs relation were taken into consideration.

  5. Interscalene brachial plexus block for open-shoulder surgery: a randomized, double-blind, placebo-controlled trial between single-shot anesthesia and patient-controlled catheter system.

    Science.gov (United States)

    Goebel, Sascha; Stehle, Jens; Schwemmer, Ulrich; Reppenhagen, Stephan; Rath, Beatrice; Gohlke, Frank

    2010-04-01

    Interscalene brachial plexus block (ISB) is widely used as an adjuvant regional pain therapy in patients undergoing major shoulder surgery and has proved its effectiveness on postoperative pain reduction and opioid-sparing effect. This single-center, prospective, double-blind, randomized and placebo-controlled study was to compare the effectiveness of a single-shot and a patient-controlled catheter insertion ISB system after major open-shoulder surgeries. Seventy patients were entered to receive an ISB and a patient-controlled interscalene catheter. The catheter was inserted under ultrasound guidance. Patients were then assigned to receive one of two different postoperative infusions, either 0.2% ropivacaine (catheter group) or normal saline solution (single-shot group) via a disposable patient-controlled infusion pump. The study variables were amount of rescue medication, pain at rest and during physiotherapy, patient satisfaction and incidence of unwanted side effects. The ropivacaine group revealed significantly less consumption of rescue medication within the first 24 h after surgery. Incidence of side effects did not differ between the two groups. Based on our results, we recommend the use of interscalene plexus block in combination with a patient-controlled catheter system under ultrasound guidance only for the first 24 h after major open-shoulder surgery.

  6. Measurement of event-related potentials and placebo

    Directory of Open Access Journals (Sweden)

    Sovilj Platon

    2014-01-01

    Full Text Available ERP is common abbreviation for event-related brain potentials, which are measured and used in clinical practice as well as in research practice. Contemporary studies of placebo effect are often based on functional neuromagnetic resonance (fMRI, positron emission tomography (PET, and event related potentials (ERP. This paper considers an ERP instrumentation system used in experimental researches of placebo effect. This instrumentation system can be divided into four modules: electrodes and cables, conditioning module, digital measurement module, and PC module for stimulations, presentations, acquisition and data processing. The experimental oddball paradigm is supported by the software of the instrumentation. [Projekat Ministarstva nauke Republike Srbije, br. TR32019 and Provincial Secretariat for Science and Technological Development of Autonomous Province of Vojvodina (Republic of Serbia under research grant No. 114-451-2723

  7. Event-related functional MRI: implications for cognitive psychology.

    Science.gov (United States)

    D'Esposito, M; Zarahn, E; Aguirre, G K

    1999-01-01

    Functional magnetic resonance imaging (fMRI) has rapidly emerged as a powerful technique in cognitive neuroscience. We describe and critique a new class of imaging experimental designs called event-related fMRI that exploit the temporal resolution of fMRI by modeling fMRI signal changes associated with behavioral trials as opposed to blocks of behavioral trials. Advantages of this method over block designs include the ability to (a) randomize trial presentations, (b) test for functional correlates of behavioral measures with greater power, (c) directly examine the neural correlates of temporally dissociable components of behavioral trials (e.g., the delay period of a working memory task), and (d) test for differences in the onset time of neural activity evoked by different trial types. Consequently, event-related fMRI has the potential to address a number of cognitive psychology questions with a degree of inferential and statistical power not previously available.

  8. Proprioceptive event related potentials: gating and task effects

    DEFF Research Database (Denmark)

    Arnfred, Sidse M

    2005-01-01

    The integration of proprioception with vision, touch or audition is considered basic to the developmental formation of perceptions, conceptual objects and the creation of cognitive schemes. Thus, mapping of proprioceptive information processing is important in cognitive research. A stimulus...... of a brisk change of weight on a hand held load elicit a proprioceptive evoked potential (PEP). Here this is used to examine early and late information processing related to weight discrimination by event related potentials (ERP)....

  9. [The use of event related potentials in psychiatric research].

    Science.gov (United States)

    Wichniak, Adam; Ciołkiewicz, Agnieszka; Waliniowska, Elzbieta; Wołkow, Lidia; Wierzbicka, Aleksandra; Jakubczyk, Tomasz; Jernajczyk, Wojciech

    2010-01-01

    Event related potentials (ERPs) originate predominantly from cortical structures in response to information processing. In contrast to evoked potentials of short latency (psychiatric research. ERPs can be also useful in clinic related questions: identification of subject at high-risk of psychosis, assessment of attention deficits or selective attention problems in anxiety disorders, evaluation of early response to psychopharmacological treatment and efficacy of psychotherapeutic interventions.

  10. Strategies to improve phase-stability of ultrafast swept source optical coherence tomography for single shot imaging of transient mechanical waves at 16 kHz frame rate

    Energy Technology Data Exchange (ETDEWEB)

    Song, Shaozhen; Wei, Wei; Hsieh, Bao-Yu; Pelivanov, Ivan; O' Donnell, Matthew [Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); Shen, Tueng T.; Wang, Ruikang K., E-mail: wangrk@uw.edu [Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); Department of Ophthalmology, University of Washington, Seattle, Washington 98104 (United States)

    2016-05-09

    We present single-shot phase-sensitive imaging of propagating mechanical waves within tissue, enabled by an ultrafast optical coherence tomography (OCT) system powered by a 1.628 MHz Fourier domain mode-locked (FDML) swept laser source. We propose a practical strategy for phase-sensitive measurement by comparing the phases between adjacent OCT B-scans, where the B-scan contains a number of A-scans equaling an integer number of FDML buffers. With this approach, we show that micro-strain fields can be mapped with ∼3.0 nm sensitivity at ∼16 000 fps. The system's capabilities are demonstrated on porcine cornea by imaging mechanical wave propagation launched by a pulsed UV laser beam, promising non-contact, real-time, and high-resolution optical coherence elastography.

  11. The effect of jogging on P300 event related potentials.

    Science.gov (United States)

    Nakamura, Y; Nishimoto, K; Akamatu, M; Takahashi, M; Maruyama, A

    1999-03-01

    Physical exercise has beneficial effects not only on cardiovascular system and fat metabolism, may also directly effect the cognitive process. We studied the effect of physical exercise on cognitive processes by measuring the P300 event related-potential (ERP) after jogging. Seven well-trained joggers were enrolled in this study and the P300 potentials using auditory oddball paradigm. ERPs were measured before and after 30 minutes of jogging. The amplitude of the P300 significantly increased after jogging compared to values recorded before jogging. These findings suggest that jogging has the effect of facilitating cognitive processes involved in generation of the P300.

  12. Dread of uncertain pain: An event-related potential study.

    Science.gov (United States)

    Huang, Yujing; Shang, Qian; Dai, Shenyi; Ma, Qingguo

    2017-01-01

    Humans experience more stress about uncertain situations than certain situations. However, the neural mechanism underlying the uncertainty of a negative stimulus has not been determined. In the present study, event-related potential was recorded to examine neural responses during the dread of unpredictable pain. We used a cueing paradigm in which predictable cues were always followed by electric shocks, unpredictable cues by electric shocks at a 50/50 ratio and safe cues by no electric shock. Visual analogue scales following electric shocks were presented to quantify subjective anxiety levels. The behavioral results showed that unpredictable cues evoked high-level anxiety compared with predictable cues in both painful and unpainful stimulation conditions. More importantly, the ERPs results revealed that unpredictable cues elicited a larger P200 at parietal sites than predictable cues. In addition, unpredictable cues evoked larger P200 compared with safe cues at frontal electrodes and compared with predictable cues at parietal electrodes. In addition, larger P3b and LPP were observed during perception of safe cues compared with predictable cues at frontal and central electrodes. The similar P3b effect was also revealed in the left sites. The present study underlined that the uncertain dread of pain was associated with threat appraisal process in pain system. These findings on early event-related potentials were significant for a neural marker and development of therapeutic interventions.

  13. Dread of uncertain pain: An event-related potential study.

    Directory of Open Access Journals (Sweden)

    Yujing Huang

    Full Text Available Humans experience more stress about uncertain situations than certain situations. However, the neural mechanism underlying the uncertainty of a negative stimulus has not been determined. In the present study, event-related potential was recorded to examine neural responses during the dread of unpredictable pain. We used a cueing paradigm in which predictable cues were always followed by electric shocks, unpredictable cues by electric shocks at a 50/50 ratio and safe cues by no electric shock. Visual analogue scales following electric shocks were presented to quantify subjective anxiety levels. The behavioral results showed that unpredictable cues evoked high-level anxiety compared with predictable cues in both painful and unpainful stimulation conditions. More importantly, the ERPs results revealed that unpredictable cues elicited a larger P200 at parietal sites than predictable cues. In addition, unpredictable cues evoked larger P200 compared with safe cues at frontal electrodes and compared with predictable cues at parietal electrodes. In addition, larger P3b and LPP were observed during perception of safe cues compared with predictable cues at frontal and central electrodes. The similar P3b effect was also revealed in the left sites. The present study underlined that the uncertain dread of pain was associated with threat appraisal process in pain system. These findings on early event-related potentials were significant for a neural marker and development of therapeutic interventions.

  14. Proprioceptive event related potentials: gating and task effects

    DEFF Research Database (Denmark)

    Arnfred, Sidse Marie

    2005-01-01

    OBJECTIVE: The integration of proprioception with vision, touch or audition is considered basic to the developmental formation of perceptions, conceptual objects and the creation of cognitive schemes. Thus, mapping of proprioceptive information processing is important in cognitive research....... A stimulus of a brisk change of weight on a hand held load elicit a proprioceptive evoked potential (PEP). Here this is used to examine early and late information processing related to weight discrimination by event related potentials (ERP). METHODS: A gating paradigm having 1s between the proprioceptive...... stimuli of 100 g weight increase was recorded in 12 runs of 40 pairs and an 1:4 oddball task of discriminating between 40 and 100 g weight increase was both recorded in 24 healthy men. The subjects were stratified in 3 groups according to their discrimination errors. RESULTS: The proprioceptive event...

  15. Event-Related Potentials and Emotion Processing in Child Psychopathology

    Directory of Open Access Journals (Sweden)

    Georgia eChronaki

    2016-04-01

    Full Text Available In recent years there has been increasing interest in the neural mechanisms underlying altered emotional processes in children and adolescents with psychopathology. This review provides a brief overview of the most up-to-date findings in the field of Event-Related Potentials (ERPs to facial and vocal emotional expressions in the most common child psychopathological conditions. In regards to externalising behaviour (i.e. ADHD, CD, ERP studies show enhanced early components to anger, reflecting enhanced sensory processing, followed by reductions in later components to anger, reflecting reduced cognitive-evaluative processing. In regards to internalising behaviour, research supports models of increased processing of threat stimuli especially at later more elaborate and effortful stages. Finally, in autism spectrum disorders abnormalities have been observed at early visual-perceptual stages of processing. An affective neuroscience framework for understanding child psychopathology can be valuable in elucidating underlying mechanisms and inform preventive intervention.

  16. Auditory P300 event-related potential in tobacco smokers.

    Science.gov (United States)

    Guney, Figen; Genc, Bulent Oguz; Kutlu, Ruhusen; Ilhan, Bilge Cetin

    2009-10-01

    The aim of this study was to elucidate the chronic effects of tobacco smoking on the P300, a neurophysiological index of cognitive function. Prospective study participants were recruited from a family medicine polyclinic. We selected 32 right-handed smokers who had smoked more than 15 cigarettes per day, by inhalation, for more than 2 years. The control population consisted of 32 right-handed, age-matched healthy individuals who had never smoked. Event-related potentials (ERPs) were recorded with the auditory "oddball" two-tone discrimination task. The data from the central (Cz) and frontal (Fz) electrodes were analyzed. The P300 and N1 amplitudes at Fz were lower in the study population compared to the control group. The early component of ERP, the measure of mental speed (N1) latency at Fz was prolonged in the study group compared to the controls, possibly because early cognitive processes such as sensory input or initial encoding of sensory information were delayed in this group. For those who smoke, a decreased N1 amplitude might indicate delayed information processing and possibly short-term memory disturbance. Thus, chronic tobacco smoking may produce prefrontal cognitive dysfunction.

  17. Social Comparison Manifests in Event-related Potentials.

    Science.gov (United States)

    Luo, Yi; Feng, Chunliang; Wu, Tingting; Broster, Lucas S; Cai, Huajian; Gu, Ruolei; Luo, Yue-jia

    2015-07-17

    Social comparison, a widespread phenomenon in human society, has been found to affect outcome evaluation. The need to belong to a social group may result in distinct neural responses to diverse social comparison outcomes. To extend previous studies by examining how social comparison with hierarchical characteristics is temporally processed, electroencephalography responses were recorded in the current study. Participants played a lottery game with two pseudo-players simultaneously and received both their own and the other two players' outcomes. Results of three event-related potential components, including the P2, the feedback-related negativity (FRN), and the late positive component (LPC), indicate that social comparison manifests in three stages. First, outcomes indicating a different performance from others elicited a larger P2 than evenness. Second, the FRN showed hierarchical sensitivity to social comparison outcomes. This effect manifested asymmetrically. Finally, large difference between the participant's outcome and the other two players' evoked a larger LPC than the medium difference and the even condition. We suggest that during social comparison, people detect if there is any difference between self and others, and then evaluate the information of this difference hierarchically, and finally interpret the situations in which oneself deviates from the group as most motivationally salient.

  18. Volumetric composition of nanocomposites

    DEFF Research Database (Denmark)

    Madsen, Bo; Lilholt, Hans; Mannila, Juha

    2015-01-01

    . An analytical model, previously established for conventional fibre composites, is used for the analysis of the volumetric composition. For the aluminosilicate/polylactate nanocomposites, based on the established linear relationship between the porosity content and the fibre volume content, the fibre correlated...... porosity factor is determined to be 0.18. Geometrical considerations of the packing of parallel nanofibres in a square array are used to make the assumption that the maximum obtainable fibre volume content in the nanocomposites will not exceed 6 % due to the small fibre spacing that restricts full matrix...... significant figures. The plotting of the measured nanocomposite density as a function of the nanofibre weight content is shown to be a first good approach of assessing the porosity content of the materials. The known gravimetric composition of the nanocomposites is converted into a volumetric composition...

  19. Changes in susceptibility signs on serial T2*-weighted single-shot echo-planar gradient-echo images in acute embolic infarction: comparison with recanalization status on 3D time-of-flight magnetic resonance angiography

    International Nuclear Information System (INIS)

    Shinohara, Yuki; Kinoshita, Toshibumi; Kinoshita, Fumiko

    2012-01-01

    The present study compares changes in susceptibility signs on follow-up single-shot echo-planar gradient-echo T2*-weighted images (GRE-EPI) with vascular status on follow-up magnetic resonance angiography (MRA) in acute embolic infarction. Twenty consecutive patients with acute embolic infarction repeatedly underwent MR imaging including GRE-EPI and MRA using a 1.5-T MR superconducting system. All patients underwent initial MR examination within 24 h of onset and follow-up MR imaging within 1 month after onset. Changes in susceptibility signs on follow-up GRE-EPI were compatible with vascular status on follow-up MRA in 19 of the 20 patients. Susceptibility signs disappeared with complete recanalization in 13 patients, migrated with partial recanalization in 3, did not change together with the absence of recanalization in 2, and became extended together with the absence of recanalization in 1. Cerebral hemorrhage obscured susceptibility signs in the one remaining patient. Susceptibility signs on follow-up GRE-EPI can reflect changes in an acute embolus, such as recanalization or migration, in this study. Serial GRE-EPI in acute embolism complements the diagnostic certainty of MRA by directly detecting an embolus as a susceptibility sign. (orig.)

  20. Event-related potential correlates of mindfulness meditation competence

    Science.gov (United States)

    Atchley, Rachel; Klee, Dan; Memmott, Tabatha; Goodrich, Elena; Wahbeh, Helané; Oken, Barry

    2016-01-01

    Objective This cross-sectional study evaluated event-related potentials (ERPs) across three groups: naïve, novice, and experienced meditators as potential physiological markers of mindfulness meditation competence. Methods Electroencephalographic (EEG) data was collected during a target tone detection task and a Breath Counting task. The Breath Counting task served as the mindfulness meditation condition for the novice and experienced meditator groups. Participants were instructed to respond to target tones with a button press in the first task (Tones), and then ignore the primed tones while breath counting. The primary outcomes were ERP responses to target tones, namely the N2 and P3, as markers of stimulus discrimination and attention, respectively. Results As expected, P3 amplitudes elicited by target tones were attenuated within groups during the Breath Counting task in comparison to the Tones task (p meditator groups displayed greater change in peak-to-trough P3 amplitudes, with higher amplitudes during the Tones condition and more pronounced reductions in P3 amplitudes during the Breath Counting meditation task in comparison to the naïve group. Conclusions Meditators had stronger P3 amplitude responses to target tones when instructed to attend to the tones, and a greater attenuation of P3 amplitudes when instructed to ignore the same tones during the Breath Counting task. This study introduces the idea of identifying ERP markers as a means of measuring mindfulness meditation competence, and results suggest this may be a valid approach. This information has the potential to improve mindfulness meditation interventions by allowing objective assessment of mindfulness meditation quality. PMID:26850995

  1. Iconic Meaning in Music: An Event-Related Potential Study

    Science.gov (United States)

    Luo, Qiuling; Huang, Hong; Mo, Lei

    2015-01-01

    Although there has been extensive research on the processing of the emotional meaning of music, little is known about other aspects of listeners’ experience of music. The present study investigated the neural correlates of the iconic meaning of music. Event-related potentials (ERP) were recorded while a group of 20 music majors and a group of 20 non-music majors performed a lexical decision task in the context of implicit musical iconic meaning priming. ERP analysis revealed a significant N400 effect of congruency in time window 260-510 ms following the onset of the target word only in the group of music majors. Time-course analysis using 50 ms windows indicated significant N400 effects both within the time window 410-460 ms and 460-510 ms for music majors, whereas only a partial N400 effect during time window 410-460 ms was observed for non-music majors. There was also a trend for the N400 effects in the music major group to be stronger than those in the non-major group in the sub-windows of 310-360ms and 410-460ms. Especially in the sub-window of 410-460 ms, the topographical map of the difference waveforms between congruent and incongruent conditions revealed different N400 distribution between groups; the effect was concentrated in bilateral frontal areas for music majors, but in central-parietal areas for non-music majors. These results imply probable neural mechanism differences underlying automatic iconic meaning priming of music. Our findings suggest that processing of the iconic meaning of music can be accomplished automatically and that musical training may facilitate the understanding of the iconic meaning of music. PMID:26161561

  2. Event-related potential correlates of mindfulness meditation competence.

    Science.gov (United States)

    Atchley, R; Klee, D; Memmott, T; Goodrich, E; Wahbeh, H; Oken, B

    2016-04-21

    This cross-sectional study evaluated event-related potentials (ERPs) across three groups: naïve, novice, and experienced meditators as potential physiological markers of mindfulness meditation competence. Electroencephalographic (EEG) data were collected during a target tone detection task and a Breath Counting task. The Breath Counting task served as the mindfulness meditation condition for the novice and experienced meditator groups. Participants were instructed to respond to target tones with a button press in the first task (Tones), and then ignore the primed tones while Breath Counting. The primary outcomes were ERP responses to target tones, namely the N2 and P3, as markers of stimulus discrimination and attention, respectively. As expected, P3 amplitudes elicited by target tones were attenuated within groups during the Breath Counting task in comparison to the Tones task (pmeditator groups displayed greater change in peak-to-trough P3 amplitudes, with higher amplitudes during the Tones condition and more pronounced reductions in P3 amplitudes during the Breath Counting meditation task in comparison to the naïve group. Meditators had stronger P3 amplitude responses to target tones when instructed to attend to the tones, and a greater attenuation of P3 amplitudes when instructed to ignore the same tones during the Breath Counting task. This study introduces the idea of identifying ERP markers as a means of measuring mindfulness meditation competence, and results suggest this may be a valid approach. This information has the potential to improve mindfulness meditation interventions by allowing objective assessment of mindfulness meditation quality. Published by Elsevier Ltd.

  3. Relationship of Event-Related Potentials to the Vigilance Decrement

    Directory of Open Access Journals (Sweden)

    Ashley Haubert

    2018-03-01

    Full Text Available Cognitive fatigue emerges in wide-ranging tasks and domains, but traditional vigilance tasks provide a well-studied context in which to explore the mechanisms underlying it. Though a variety of experimental methodologies have been used to investigate cognitive fatigue in vigilance, relatively little research has utilized electroencephalography (EEG, specifically event-related potentials (ERPs, to explore the nature of cognitive fatigue, also known as the vigilance decrement. Moreover, much of the research that has been done on vigilance and ERPs uses non-traditional vigilance paradigms, limiting generalizability to the established body of behavioral results and corresponding theories. In this study, we address concerns with prior research by (1 investigating the vigilance decrement using a well-established visual vigilance task, (2 utilizing a task designed to attenuate possible confounding ERP components present within a vigilance paradigm, and (3 informing our interpretations with recent findings from ERP research. We averaged data across electrodes located over the frontal, central, and parietal scalp. Then, we generated waveforms locked to the onset of critical low-frequency or non-critical high-frequency events during a 40 min task that was segregated into time blocks for data analysis. There were three primary findings from the analyses of these data. First, mean amplitude of N1 was greater during later blocks for both low-frequency and high-frequency events, a contradictory finding compared to past visual vigilance studies that is further discussed with respect to current interpretations of the N1 in visual attention tasks. Second, P3b mean amplitude following low-frequency events was reduced during later blocks, with a later onset latency. Third and finally, the decrease in P3b amplitude correlated with individual differences in the magnitude of the vigilance decrement, assessed using d′. The results provide evidence for degradations

  4. Flexible Volumetric Structure

    Science.gov (United States)

    Cagle, Christopher M. (Inventor); Schlecht, Robin W. (Inventor)

    2014-01-01

    A flexible volumetric structure has a first spring that defines a three-dimensional volume and includes a serpentine structure elongatable and compressible along a length thereof. A second spring is coupled to at least one outboard edge region of the first spring. The second spring is a sheet-like structure capable of elongation along an in-plane dimension thereof. The second spring is oriented such that its in-plane dimension is aligned with the length of the first spring's serpentine structure.

  5. Single shot high resolution digital holography.

    Science.gov (United States)

    Khare, Kedar; Ali, P T Samsheer; Joseph, Joby

    2013-02-11

    We demonstrate a novel computational method for high resolution image recovery from a single digital hologram frame. The complex object field is obtained from the recorded hologram by solving a constrained optimization problem. This approach which is unlike the physical hologram replay process is shown to provide high quality image recovery even when the dc and the cross terms in the hologram overlap in the Fourier domain. Experimental results are shown for a Fresnel zone hologram of a resolution chart, intentionally recorded with a small off-axis reference beam angle. Excellent image recovery is observed without the presence of dc or twin image terms and with minimal speckle noise.

  6. Single-Shot Echo-Planar Diffusion-Weighted MR Imaging at 3T and 1.5T for Differentiation of Benign Vertebral Fracture Edema and Tumor Infiltration

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hee Jin; Lee, So Yeon; Rho, Myung Ho; Chung, Eun Chul; Kim, Mi Sung; Kwon, Heon Ju; Youn, In Young [Department of Radiology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul 03181 (Korea, Republic of)

    2016-11-01

    To compare the apparent diffusion coefficient (ADC) value using single-shot echo-planar imaging sequences at 3T and 1.5T for differentiation of benign fracture edema and tumor infiltration of the vertebral body. A total of 46 spinal examinations were included in the 1.5T MRI group, and a total of 40 spinal examinations were included in the 3T MRI group. The ADC values of the lesion were measured and calculated. The diagnostic performance of the conventional MR image containing sagittal T2-weighted fat saturated image and each diffusion weighted image (DWI) with an ADC value with different b values were evaluated. The mean ADC value of the benign lesions was higher than that of the malignant lesions on 1.5T and 3T (p < 0.05). The sensitivity of the diagnostic performance was higher with an additional DWI in both 1.5T and 3T, but the sensitivities were similar with the addition of b values of 400 and 1000. The specificities of the diagnostic performances did not show significant differences (p value > 0.05). The diagnostic accuracies were higher when either of the DWIs (b values of 400 and 1000) was added to routine MR image for 1.5T and 3T. Statistical differences between 1.5T and 3T or between b values of 400 and 1000 were not seen. The ADC values of the benign lesions were significantly higher than those of the malignant lesions on 1.5T and 3T. There was no statistically significant difference in the diagnostic performances when either of the DWIs (b values of 400 and 1000) was added to the routine MR image for 1.5T and 3T.

  7. Readout-segmented echo-planar imaging improves the image quality of diffusion-weighted MR imaging in rectal cancer: Comparison with single-shot echo-planar diffusion-weighted sequences

    Energy Technology Data Exchange (ETDEWEB)

    Xia, Chun-chao; Liu, Xi; Peng, Wan-lin; Li, Lei; Zhang, Jin-ge [Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Meng, Wen-jian; Deng, Xiang-bing [Department of Gastrointestinal Surgery, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China); Zuo, Pan-li [Siemens Healthcare, MR Collaborations NE Asia, 100010, Beijing (China); Li, Zhen-lin, E-mail: lzlcd01@126.com [Department of Radiology, West China Hospital, Sichuan University, 37# Guo Xue Xiang, Chengdu, Sichuan 610041 (China)

    2016-10-15

    Purpose: To determine whether readout-segmented echo-planar imaging (rs-EPI) diffusion-weighted imaging (DWI) can improve the image quality in patients with rectal cancer compared with single-shot echo-planar imaging (ss-EPI) DWI using 3.0 T magnetic resonance (MR) imaging. Materials and methods: This study was approved by the Institutional Review Board, and informed consent was obtained from all patients. Seventy-one patients with rectal cancer were enrolled in this study. For all patients, both rs-EPI and ss-EPI DWI were performed using a 3T MR scanner. Two radiologists independently assessed the overall image quality, lesion conspicuity, geometric distortion and distinction of anatomical structures. The signal-to-noise ratio (SNR), lesion contrast, contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) were also measured. Comparisons of the quantitative and qualitative parameters between the two sequences were performed using the paired t-test and the Wilcoxon signed rank test. Results: The scores of overall image quality, lesion conspicuity, geometric distortion and distinction of anatomical structures of rs-EPI were all significantly higher than those of ss-EPI (all p < 0.05). The SNR and CNR were higher in rs-EPI than those in ss-EPI (all p < 0.05). There was no significant difference between ss-EPI and rs-EPI with regard to ROI size and mean ADCs of the tumour (p = 0.574 and p = 0.479, respectively), but the mean ADC of the normal tissue was higher in rs-EPI than in ss-EPI (1.73 ± 0.30 × 10{sup −3} mm{sup 2}/s vs. 1.60 ± 0.31 × 10{sup −3} mm{sup 2}/s, p = 0.001). Conclusions: DW imaging based on readout-segmented echo-planar imaging is a clinically useful technique to improve the image quality for the purpose of evaluating lesions in patients with rectal tumours.

  8. Parametric model of volumetric scattering

    Science.gov (United States)

    Magarill, Simon; Cassarly, William J.; Jenkins, David R.; Yang, Yang; Yu, Xiaofeng; Liu, Guang

    2017-11-01

    We develop a method to determine volumetric scattering model parameter values based on measured BSDF characteristics. Example models often use Mie or Gegenbauer particles. The accuracy and flexibility of this approach are illustrated.

  9. An event-related potential study on memory search for color

    OpenAIRE

    Miyatani, Makoto; Nakao, Takasi; Ohkawa, Kaori; Sanderson, Nicholas S. R.; Takumi, Ken

    2002-01-01

    The present study focused on memory search processes in nonverbal working memory. Event-related potentials (ERPs) were recorded while subjects engaged in two memory search tasks. Effects of memory set size on event-related potentials were compared between when memory sets consisted of one or four alphabets and when one to three unvocable color patches composed memory sets. In a letter search task, increase of memory set size caused the enlargement of negativities of ERPs between 250 and 450 m...

  10. Efficient threshold for volumetric segmentation

    Science.gov (United States)

    Burdescu, Dumitru D.; Brezovan, Marius; Stanescu, Liana; Stoica Spahiu, Cosmin; Ebanca, Daniel

    2015-07-01

    Image segmentation plays a crucial role in effective understanding of digital images. However, the research on the existence of general purpose segmentation algorithm that suits for variety of applications is still very much active. Among the many approaches in performing image segmentation, graph based approach is gaining popularity primarily due to its ability in reflecting global image properties. Volumetric image segmentation can simply result an image partition composed by relevant regions, but the most fundamental challenge in segmentation algorithm is to precisely define the volumetric extent of some object, which may be represented by the union of multiple regions. The aim in this paper is to present a new method to detect visual objects from color volumetric images and efficient threshold. We present a unified framework for volumetric image segmentation and contour extraction that uses a virtual tree-hexagonal structure defined on the set of the image voxels. The advantage of using a virtual tree-hexagonal network superposed over the initial image voxels is that it reduces the execution time and the memory space used, without losing the initial resolution of the image.

  11. The influence of event-related knowledge on verb-argument processing in aphasia.

    Science.gov (United States)

    Dickey, Michael Walsh; Warren, Tessa

    2015-01-01

    Event-related conceptual knowledge outside the language system rapidly affects verb-argument processing in unimpaired adults (McRae and Matsuki, 2009). Some have argued that verb-argument processing is in fact reducible to the activation of such event-related knowledge. However, data favoring this conclusion have come primarily from college-aged healthy adults, for whom both linguistic and conceptual semantic processing is fast and automatic. This study examined the influence of event-related knowledge on verb-argument processing among adults with aphasia (n = 8) and older unimpaired controls (n = 60), in two self-paced reading studies. Participants read sentences containing a plausible verb-argument combination (Mary used a knife to chop the large carrots before dinner), a combination that violated event-related world knowledge (Mary used some bleach to clean the large carrots before dinner), or a combination that violated the verb's selectional restrictions (Mary used a pump to inflate the large carrots before dinner). The participants with aphasia naturally split into two groups: Group 1 (n = 4) had conceptual-semantic impairments (evidenced by poor performance on tasks like Pyramids & Palm Trees) but reasonably intact language processing (higher Western Aphasia Battery Aphasia Quotients), while Group 2 (n = 4) had intact conceptual semantics but poorer language processing. Older unimpaired controls and aphasic Group 1 showed rapid on-line disruption for sentences with selectional-restriction violations (SRVs) and event-related knowledge violations, and also showed SRV-specific penalties in sentence-final acceptability judgments (Experiment 1) and comprehension questions (Experiment 2). In contrast, Group 2 showed very few reliable differences across conditions in either on-line or off-line measures. This difference between aphasic groups suggests that verb-related information and event-related knowledge may be dissociated in aphasia. Furthermore, it suggests

  12. Kilohertz VLIF (volumetric laser induced fluorescence) measurements in a seeded free gas-phase jet in the transitionally turbulent flow regime

    Science.gov (United States)

    Wu, Yue; Xu, Wenjiang; Ma, Lin

    2018-03-01

    This paper reports the demonstration of instantaneous three-dimension (3D) measurements in turbulent flows at repetition rates up to 10 kHz using VLIF (volumetric laser induced fluorescence). The measurements were performed based on the LIF signal of iodine (I2) vapor seeded in the flow. The LIF signals of I2 vapor were generated volumetrically by a thick laser slab and then simultaneously captured by a total of seven cameras from different perspectives, based on which a 3D tomographic reconstruction was performed to obtain the 3D distribution of I2 vapor concentration. Single-shot measurements obtained in a duration of hundreds of nanoseconds (limited by the pulse duration of the excitation laser) were demonstrated in a 50 × 50 × 50 mm3 at a repetition rate up to 10 kHz. These measurements demonstrated the feasibility and potential of VLIF for resolving the 4D spatiotemporal dynamics of turbulent flows. Based on the experimental results obtained, this work also studied the VLIF signal level and its effects on the reconstruction accuracy under different the measurement conditions, illustrating the capabilities and limitations of performing high speed VLIF measurements.

  13. Attentional Mechanisms in Sports via Brain-Electrical Event-Related Potentials

    Science.gov (United States)

    Hack, Johannes; Memmert, Daniel; Rup, Andre

    2009-01-01

    In this study, we examined attention processes in complex, sport-specific decision-making tasks without interdependencies from anticipation. Psychophysiological and performance data recorded from advanced and intermediate level basketball referees were compared. Event-related potentials obtained while judging game situations in foul recognition…

  14. Snake scales, partial exposure, and the Snake Detection Theory: A human event-related potentials study

    NARCIS (Netherlands)

    J.W. van Strien (Jan); L.A. Isbell (Lynne A.)

    2017-01-01

    textabstractStudies of event-related potentials in humans have established larger early posterior negativity (EPN) in response to pictures depicting snakes than to pictures depicting other creatures. Ethological research has recently shown that macaques and wild vervet monkeys respond strongly to

  15. Effects of Experience and Task Difficulty on Event-Related Potentials

    Science.gov (United States)

    1989-10-13

    indexing performance. In K. Atsumi, T. Katila, H. Kotani, S. G. Williamson, & K. Ueno (Eds.) Biomagnetism 198y7,Proceedings of the oth International...Conference on Biomagnetism . To y, Japan. --- Lindholm, E. & Koriath, J. J. (1985). Analysis of multiple event-related potential components in a tone

  16. Event-related EEG changes preceding saccadic eye movements before and after dry immersion.

    Science.gov (United States)

    Tomilovskaya, E S; Kirenskaya, A V; Novototski-Vlasov, V Yu; Kozlovskaya, I B

    2004-07-01

    Objectives of this work were to quantify antisaccade characteristics, presaccadic slow negative EEG-potentials, and event-related EEG frequency band power (theta, alpha1, alpha2, beta1, beta2 and beta3) changes (ERD) in healthy volunteers before and after 6-day simulated weightlessness (dry immersion).

  17. Event-Related Potentials and Consonant Differentiation in Newborns with Familial Risk for Dyslexia.

    Science.gov (United States)

    Guttorm, Tomi K.; Leppanen, Paavo H. T.; Richardson, Ulla; Lyytinen, Heikki

    2001-01-01

    This study examined event-related potentials (ERPs) to synthetic consonant-vowel syllables from 26 newborns with familial risk for dyslexia and 23 control infants participating in a longitudinal study of dyslexia. Results indicated that the cortical electric activation evoked by speech elements differed between children with and without risk for…

  18. Two Languages, One Developing Brain: Event-Related Potentials to Words in Bilingual Toddlers

    Science.gov (United States)

    Conboy, Barbara T.; Mills, Debra L.

    2006-01-01

    Infant bilingualism offers a unique opportunity to study the relative effects of language experience and maturation on brain development, with each child serving as his or her own control. Event-related potentials (ERPs) to words were examined in 19- to 22-month-old English-Spanish bilingual toddlers. The children's dominant vs. nondominant…

  19. Atypical Brain Responses to Reward Cues in Autism as Revealed by Event-Related Potentials

    Science.gov (United States)

    Kohls, Gregor; Peltzer, Judith; Schulte-Ruther, Martin; Kamp-Becker, Inge; Remschmidt, Helmut; Herpertz-Dahlmann, Beate; Konrad, Kerstin

    2011-01-01

    Social motivation deficit theories suggest that children with autism do not properly anticipate and appreciate the pleasure of social stimuli. In this study, we investigated event-related brain potentials evoked by cues that triggered social versus monetary reward anticipation in children with autism. Children with autism showed attenuated P3…

  20. Temporal evolution of event-related desynchronization in acute stroke: A pilot study

    NARCIS (Netherlands)

    Tangwiriyasakul, Chayanin; Verhagen, Rens; Rutten, Wim; van Putten, Michel Johannes Antonius Maria

    2014-01-01

    Objective Assessment of event-related desynchronization (ERD) may assist in predicting recovery from stroke and rehabilitation, for instance in BCI applications. Here, we explore the temporal evolution of ERD during stroke recovery. Methods Ten stroke patients and eleven healthy controls were

  1. Complement Set Reference after Implicitly Small Quantities: An Event-Related Potentials Study

    Science.gov (United States)

    Ingram, Joanne; Ferguson, Heather J.

    2018-01-01

    An anaphoric reference to the complement-set is a reference to the set that does not fulfil the predicate of the preceding sentence. Preferred reference to the complement-set has been found in eye movements when a character's implicit desire for a high amount has been denied using a negative emotion. We recorded event-related potentials to examine…

  2. MODULATION OF EVENT-RELATED POTENTIALS BY WORD REPETITION - THE ROLE OF VISUAL SELECTIVE ATTENTION

    NARCIS (Netherlands)

    OTTEN, LJ; RUGG, MD; DOYLE, MC

    1993-01-01

    Event-related potentials (ERPs) were recorded while subjects viewed visually presented words, some of which occurred twice. Each trial consisted of two colored letter strings, the requirement being to attend to and make a word/nonword discrimination for one of the strings. Attention was manipulated

  3. Auditory Processing in Dyslexia: Middle Latency Event-Related Potentials and Temporal Sequencing.

    Science.gov (United States)

    Krull, Kevin R.

    Behavioral and electrophysiological processing of sequential tones were investigated in reading delayed (RD) and non-reading delayed (NRD) children matched on intelligence and reading level. NRD children performed consistently better on sequencing of tonal patterns. Middle latency event-related potentials from the RD group indicated reduced…

  4. Event-related Potentials Reflecting the Processing of Phonological Constraint Violations

    NARCIS (Netherlands)

    Domahs, Ulrike; Kehrein, Wolfgang; Knaus, Johannes; Wiese, Richard; Schlesewsky, Matthias

    2009-01-01

    Flow are violations of phonological constraints processed in word comprehension? The present article reports the results of ail event-related potentials (ERP) Study oil a phonological constraint of German that disallows identical segments within it syllable or word (CC(i)VC(i)). We examined three

  5. Event-related potentials reflecting the processing of phonological constraint violations

    NARCIS (Netherlands)

    Domahs, U.; Kehrein, W.; Knaus, J.; Wiese, R.; Schlesewsky, M.

    2009-01-01

    How are violations of phonological constraints processed in word comprehension? The present article reports the results of an event-related potentials (ERP) study on a phonological constraint of German that disallows identical segments within a syllable or word (CC iVCi). We examined three types of

  6. Effects of sleep deprivation on event-related fields and alpha activity during rhythmic force production

    NARCIS (Netherlands)

    Boonstra, T.W.; Daffertshofer, A.; Beek, P.J.

    2005-01-01

    The influence of sleep deprivation (SD) on event-related fields and the distribution of power over the scalp of MEG imaged brain activity was studied during acoustically paced rhythmic force production. At the behavioral level, SD resulted in a reduction of the lag (negative asynchrony) between

  7. Gender Differences in Memory Processing: Evidence from Event-Related Potentials to Faces

    Science.gov (United States)

    Guillem, F.; Mograss, M.

    2005-01-01

    This study investigated gender differences on memory processing using event-related potentials (ERPs). Behavioral data and ERPs were recorded in 16 males and 10 females during a recognition memory task for faces. The behavioral data results showed that females performed better than males. Gender differences on ERPs were evidenced over anterior…

  8. Representations in human visual short-term memory : an event-related brain potential study

    NARCIS (Netherlands)

    Klaver, P; Smid, HGOM; Heinze, HJ

    1999-01-01

    Behavioral measures and event-related potentials (ERPs) were recorded from 12 subjects while performing three delayed matching-to-sample tasks. The task instructions indicated whether stimulus locations, shapes or conjunctions of locations and shapes had to be memorized and matched against a probe.

  9. An event-related brain potential correlate of visual short-term memory

    NARCIS (Netherlands)

    Klaver, Peter; Talsma, D.; Wijers, Albertus; Heinze, Hans-Jochen; Mulder, Gijsbertus

    1999-01-01

    EVENT-RELATED potentials (ERPs) were recorded as 12 subjects performed a delayed matching to sample task. We presented two bilateral abstract shapes and cued spatially which had to be memorized for a subsequent matching task: left, right or both. During memorization a posterior slow negative ERP

  10. Pitch Discrimination without Awareness in Congenital Amusia: Evidence from Event-Related Potentials

    Science.gov (United States)

    Moreau, Patricia; Jolicoeur, Pierre; Peretz, Isabelle

    2013-01-01

    Congenital amusia is a lifelong disorder characterized by a difficulty in perceiving and producing music despite normal intelligence and hearing. Behavioral data have indicated that it originates from a deficit in fine-grained pitch discrimination, and is expressed by the absence of a P3b event-related brain response for pitch differences smaller…

  11. Single-trial normalization for event-related spectral decomposition reduces sensitivity to noisy trials

    Directory of Open Access Journals (Sweden)

    Romain eGrandchamp

    2011-09-01

    Full Text Available In EEG research, the classical Event-Related Potential (ERP model often proves to be a limited method when studying complex brain dynamics. For this reason, spectral techniques adapted from signal processing such as Event-Related Spectral Perturbation (ERSP – and its variant ERS (Event-Related Synchronization and ERD (Event-Related Desynchronization – have been used over the past 20-years. They represent average spectral changes in response to a stimulus.These spectral methods do not have strong consensus for comparing pre and post-stimulus activity. When computing ERSP, pre-stimulus baseline removal is usually performed after averaging the spectral estimate of multiple trials. Correcting the baseline of each single-trial prior to averaging spectral estimates is an alternative baseline correction method. However, we show that this method leads to positively skewed post-stimulus ERSP values. We eventually present new single-trial based ERSP baseline correction methods that perform trial normalization or centering prior to applying classical baseline correction methods. We show that single-trial correction methods minimize the contribution of artifactual data trials with high-amplitude spectral estimates and are robust to outliers when performing statistical inference testing. We then characterize these methods in terms of their time-frequency responses and behavior when performing statistical inference testing compared to classical ERSP methods.

  12. Priming prepositional phrase attachment: Evidence from eye-tracking and event-related potentials

    NARCIS (Netherlands)

    Boudewyn, M.A.; Zirnstein, M.; Swaab, T.Y.; Traxler, M.J.

    2014-01-01

    Three syntactic-priming experiments investigated the effect of structurally similar or dissimilar prime sentences on the processing of target sentences, using eye tracking (Experiment 1) and event-related potentials (ERPs) (Experiments 2 and 3) All three experiments tested readers' response to

  13. MEG event-related desynchronization and synchronization deficits during basic somatosensory processing in individuals with ADHD

    Directory of Open Access Journals (Sweden)

    Wang Frank

    2008-02-01

    Full Text Available Abstract Background Attention-Deficit/Hyperactivity Disorder (ADHD is a prevalent, complex disorder which is characterized by symptoms of inattention, hyperactivity, and impulsivity. Convergent evidence from neurobiological studies of ADHD identifies dysfunction in fronto-striatal-cerebellar circuitry as the source of behavioural deficits. Recent studies have shown that regions governing basic sensory processing, such as the somatosensory cortex, show abnormalities in those with ADHD suggesting that these processes may also be compromised. Methods We used event-related magnetoencephalography (MEG to examine patterns of cortical rhythms in the primary (SI and secondary (SII somatosensory cortices in response to median nerve stimulation, in 9 adults with ADHD and 10 healthy controls. Stimuli were brief (0.2 ms non-painful electrical pulses presented to the median nerve in two counterbalanced conditions: unpredictable and predictable stimulus presentation. We measured changes in strength, synchronicity, and frequency of cortical rhythms. Results Healthy comparison group showed strong event-related desynchrony and synchrony in SI and SII. By contrast, those with ADHD showed significantly weaker event-related desynchrony and event-related synchrony in the alpha (8–12 Hz and beta (15–30 Hz bands, respectively. This was most striking during random presentation of median nerve stimulation. Adults with ADHD showed significantly shorter duration of beta rebound in both SI and SII except for when the onset of the stimulus event could be predicted. In this case, the rhythmicity of SI (but not SII in the ADHD group did not differ from that of controls. Conclusion Our findings suggest that somatosensory processing is altered in individuals with ADHD. MEG constitutes a promising approach to profiling patterns of neural activity during the processing of sensory input (e.g., detection of a tactile stimulus, stimulus predictability and facilitating our

  14. Cortical Neural Synchronization Underlies Primary Visual Consciousness of Qualia: Evidence from Event-Related Potentials

    OpenAIRE

    Babiloni, Claudio; Marzano, Nicola; Soricelli, Andrea; Cordone, Susanna; Mill?n-Calenti, Jos? Carlos; Del Percio, Claudio; Buj?n, Ana

    2016-01-01

    This article reviews three experiments on event-related potentials (ERPs) testing the hypothesis that primary visual consciousness (stimulus self-report) is related to enhanced cortical neural synchronization as a function of stimulus features. ERP peak latency and sources were compared between “seen” trials and “not seen” trials, respectively related and unrelated to the primary visual consciousness. Three salient features of visual stimuli were considered (visuospatial, emotional face expre...

  15. An Event-related Brain Potential Study of English Morphosyntactic Processing in Japanese Learners of English

    OpenAIRE

    Tatsuta, Natsuko

    2014-01-01

    This dissertation investigated the neural mechanisms underlying English morphosyntactic processing in Case, subject-verb agreement, and past tense inflection in Japanese learners of English (JLEs) using event-related brain potentials (ERPs) in terms of the effects of the age of second language (L2) acquisition (the age of learning English), L2 proficiency level (the English proficiency level), and native/first language (L1) transfer. Researchers have debated for a number of years the question...

  16. The origin and nature of categorical perception of colour: Evidence from event-related brain potentials.

    OpenAIRE

    Clifford, Alexandra.

    2009-01-01

    Categorical perception (CP) of colour is demonstrated by faster or more accurate discrimination of colours that cross a category boundary, compared to equivalently spaced colours from the same colour category. Despite a plethora of behavioural research exploring the origin and nature of colour CP, the processes involved in the effect are still unresolved. This thesis investigates the time course and underlying mechanisms of colour CP by using the Event-Related Potential (ERP) technique. This ...

  17. Change detection in children with autism: an auditory event-related fMRI study

    OpenAIRE

    Gomot, M; Bernard, FA; Davis, MH; Belmonte, MK; Ashwin, C; Bullmore, ET; Baron-Cohen, S

    2006-01-01

    Autism involves impairments in communication and social interaction, as well as high levels of repetitive, stereotypic and ritualistic behaviours, and extreme resistance to change. This latter dimension, whilst required for a diagnosis, has received less research attention. We hypothesise that this extreme resistance to change in autism is rooted in atypical processing of unexpected stimuli. We tested this using auditory event-related fMRI to determine regional brain activity associated with ...

  18. Simultaneous functional near-infrared brain imaging and event-related potential studies of Stroop effect

    Science.gov (United States)

    Zhai, Jiahuan; Li, Ting; Zhang, Zhongxing; Gong, Hui

    2009-02-01

    Functional near-infrared brain imaging (fNIRI) and event-related potential (ERP) were used simultaneous to detect the prefrontal cortex (PFC) which is considered to execute cognitive control of the subjects while performing the Chinese characters color-word matching Stroop task with event-related design. The fNIRI instrument is a portable system operating at three wavelengths (735nm & 805nm &850nm) with continuous-wave. The event-related potentials were acquired by Neuroscan system. The locations of optodes corresponding to the electrodes were defined four areas symmetrically. In nine native Chinese-speaking fit volunteers, fNIRI measured the hemodynamic parameters (involving oxy-/deoxy- hemoglobin) changes when the characteristic waveforms (N500/P600) were recorded by ERP. The interference effect was obvious as a longer reaction time for incongruent than congruent and neutral stimulus. The responses of hemodynamic and electrophysiology were also stronger during incongruent compared to congruent and neutral trials, and these results are similar to those obtained with fNIRI or ERP separately. There are high correlations, even linear relationship, in the two kinds of signals. In conclusion, the multi-modality approach combining of fNIRI and ERP is feasible and could obtain more cognitive function information with hemodynamic and electrophysiology signals. It also provides a perspective to prove the neurovascular coupling mechanism.

  19. [Olfactory functional magnetic resonance imaging with modified OEP-98C olfactometer and event-related design].

    Science.gov (United States)

    You, Hui; Wang, Jian; Liu, Jian-Feng; Feng, Feng; Ni, Dao-Feng; Jin, Zheng-Yu

    2009-04-01

    To explore the feasibility of functional magnetic resonance imaging (fMRI) in analysis of olfaction function with modified OEP-98C olfactometer and event-related design. Six young right-handed men underwent olfactory fMRI with event-related design. OEP-98C olfactometer was modified to accommodate MR environment. There were 2 types of tasks in the experiment. In one task, only isoamyl acetate was used as odorant. In the other task, to avoid possible decreased olfactory attention, vanillin was given before each presentation of isoamyl acetate. In both tasks, uniform activation in piriform cortex and secondary olfactory cortexes was determined. The activation of piriform cortex was not significantly different between the two tasks (P > 0.01). With isoamyl acetate as odorant, modified OEP-98C olfactometer, and event-related design, olfaction fMRI can depict cortex activation at primary and secondary olfactory cortex. Applying other odorant with similar quality to avoid olfactory attention decrease can not promote depiction of activation in primary olfactory cortex.

  20. A reduced volumetric expansion factor plot

    Science.gov (United States)

    Hendricks, R. C.

    1979-01-01

    A reduced volumetric expansion factor plot has been constructed for simple fluids which is suitable for engineering computations in heat transfer. Volumetric expansion factors have been found useful in correlating heat transfer data over a wide range of operating conditions including liquids, gases and the near critical region.

  1. Acute low-level alcohol consumption reduces phase locking of event-related oscillations in rodents.

    Science.gov (United States)

    Amodeo, Leslie R; Wills, Derek N; Ehlers, Cindy L

    2017-07-14

    Event-related oscillations (EROs) are rhythmic changes that are evoked by a sensory and/or cognitive stimulus that can influence the dynamics of the EEG. EROs are defined by the decomposition of the EEG signal into magnitude (energy) and phase information and can be elicited in both humans and animals. EROs have been linked to several relevant genes associated with ethanol dependence phenotypes in humans and are altered in selectively bred alcohol-preferring rats. However, pharmacological studies are only beginning to emerge investigating the impact low intoxicating doses of ethanol can have on event-related neural oscillations. The main goal of this study was to investigate the effects of low levels of voluntary consumption of ethanol, in rats, on phase locking of EROs in order to give further insight into the acute intoxicating effects of ethanol on the brain. To this end, we allow rats to self-administer unsweetened 20% ethanol over 15 intermittent sessions. This method results in a stable low-dose consumption of ethanol. Using an auditory event-related potential "oddball" paradigm, we investigated the effects of alcohol on the phase variability of EROs from electrodes implanted into the frontal cortex, dorsal hippocampus, and amygdala. We found that intermittent ethanol self-administration was sufficient to produce a significant reduction in overall intraregional synchrony across all targeted regions. These data suggest that phase locking of EROs within brain regions known to be impacted by alcohol may represent a sensitive biomarker of low levels of alcohol intoxication. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Superior digit memory of abacus experts: an event-related functional MRI study.

    Science.gov (United States)

    Tanaka, Satoshi; Michimata, Chikashi; Kaminaga, Tatsuro; Honda, Manabu; Sadato, Norihiro

    2002-12-03

    Abacus experts exhibit superior short-term memory for digits, but the underlying neurophysiological mechanism remains unknown. Using event-related fMRI, we examined the brain activity of abacus experts and non-experts during the memory retention period of a delayed match-to-sample task using digits as stimuli. In controls, activity was greater in cortical areas related to verbal working memory, including Broca's area. In contrast, in experts, activity was greater in cortical areas related to visuo-spatial working memory, including the bilateral superior frontal sulcus and superior parietal lobule. This provides neurophysiological evidence that abacus experts utilize a visuo-spatial representation for digit memory.

  3. Event-related potentials reveal increased distraction by salient global objects in older adults

    DEFF Research Database (Denmark)

    Wiegand, Iris; Finke, Kathrin; Töllner, Thomas

    Age-related changes in visual functions influence how older individuals perceive and react upon objects in their environment. In particular, older individuals might be more distracted by highly salient, irrelevant information. Kanizsa figures induce a ‘global precedence’ effect, which reflects...... a processing advantage for salient whole-object representations relative to configurations of local elements not inducing a global form. We investigated event-related potential (ERP) correlates of age-related decline in visual abilities, and specifically, distractibility by salient global objects in visual...

  4. P300- like event related potential amplitude in rats is a correlate of conditioned reinforcement

    OpenAIRE

    William D. Klipec; Steven Faux

    2012-01-01

    We have developed a methodology for recording a robust P300 event related potential (ERP) in rats. In these experiments a contingency shaped model of the human “oddball’ paradigm was employed in which rats were shaped to press a lever for food reinforcement signaled by the click of the pellet dispenser. A target tone cued the insertion of the lever that retracted after 1­sec or immediately following a single reinforced response, while a non­target tone was randomly ...

  5. Cognitive event-related potentials in comatose and post-comatose states.

    Science.gov (United States)

    Vanhaudenhuyse, Audrey; Laureys, Steven; Perrin, Fabien

    2008-01-01

    We review the interest of cognitive event-related potentials (ERPs) in comatose, vegetative, or minimally conscious patients. Auditory cognitive ERPs are useful to investigate residual cognitive functions, such as echoic memory (MMN), acoustical and semantic discrimination (P300), and incongruent language detection (N400). While early ERPs (such as the absence of cortical responses on somatosensory-evoked potentials) predict bad outcome, cognitive ERPs (MMN and P300) are indicative of recovery of consciousness. In coma-survivors, cognitive potentials are more frequently obtained when using stimuli that are more ecologic or have an emotional content (such as the patient's own name) than when using classical sine tones.

  6. Cortical localization of cognitive function by regression of performance on event-related potentials.

    Science.gov (United States)

    Montgomery, R W; Montgomery, L D; Guisado, R

    1992-10-01

    This paper demonstrates a new method of mapping cortical localization of cognitive function, using electroencephalographic (EEG) data. Cross-subject regression analyses are used to identify cortical sites and post-stimulus latencies where there is a high correlation between subjects' performance and their cognitive event-related potential (ERP) amplitude. The procedure was tested using a mental arithmetic task and was found to identify essentially the same cortical regions that have been associated with such tasks on the basis of research with patients suffering localized cortical lesions. Thus, it appears to offer an inexpensive, noninvasive tool for exploring the dynamics of localization in neurologically normal subjects.

  7. Cortical localization of cognitive function by regression of performance on event-related potentials

    Science.gov (United States)

    Montgomery, R. W.; Montgomery, L. D.; Guisado, R.

    1992-01-01

    This paper demonstrates a new method of mapping cortical localization of cognitive function, using electroencephalographic data. Cross-subject regression analyses are used to identify cortical sites and post-stimulus latencies where there is a high correlation between subjects' performance and their cognitive event-related potential amplitude. The procedure was tested using a mental arithmetic task and was found to identify essentially the same cortical regions that have been associated with such tasks on the basis of research with patients suffering localized cortical lesions. Thus, it appears to offer an inexpensive, noninvasive tool for exploring the dynamics of localization in neurologically normal subjects.

  8. Stereotype activation is unintentional: Behavioural and event-related potenials evidence.

    Science.gov (United States)

    Wang, Pei; Yang, Ya-Ping; Tan, Chen-Hao; Zhao, Xiang-Xia; Liu, Yong-He; Lin, Chong-De

    2016-04-01

    In this study, a priming Stroop paradigm was used to determine whether stereotype activation is unintentional. Priming conditions (priming/no-priming) and the relationship between priming and target (consistent/inconsistent/no-relation) were the independent variables; accuracy, reaction time and N400 amplitude were used as dependent variables. The reaction time revealed that stereotype activation is, to some extent, unintentional. Furthermore, the event-related potenial (ERP) results showed that N400 amplitude was larger for inconsistent conditions than for consistent conditions. This result supported the notion that stereotype activation is an unintentional and automatic process. © 2015 International Union of Psychological Science.

  9. ERPWAVELAB a toolbox for multi-channel analysis of time-frequency transformed event related potentials.

    Science.gov (United States)

    Mørup, Morten; Hansen, Lars Kai; Arnfred, Sidse M

    2007-04-15

    The open source toolbox 'ERPWAVELAB' is developed for multi-channel time-frequency analysis of event related activity of EEG and MEG data. The toolbox provides tools for data analysis and visualization of the most commonly used measures of time-frequency transformed event related data as well as data decomposition through non-negative matrix and multi-way (tensor) factorization. The decompositions provided can accommodate additional dimensions like subjects, conditions or repeats and as such they are perfected for group analysis. Furthermore, the toolbox enables tracking of phase locked activity from one channel-time-frequency instance to another as well as tools for artifact rejection in the time-frequency domain. Several other features are highlighted. ERPWAVELAB can freely be downloaded from www.erpwavelab.org, requires EEGLAB [Delorme A, Makeig S. EEGLAB: an open source toolbox for analysis of single-trial EEG dynamics including independent component analysis. J Neurosci Meth 2004;134:9-21] and runs under MATLAB (The Mathworks, Inc.).

  10. Effects of Stimulus Duration on Event-Related Potentials Recorded From Cochlear-Implant Users.

    Science.gov (United States)

    Presacco, Alessandro; Innes-Brown, Hamish; Goupell, Matthew J; Anderson, Samira

    Several studies have investigated the feasibility of using electrophysiology as an objective tool to efficiently map cochlear implants. A pervasive problem when measuring event-related potentials is the need to remove the direct-current (DC) artifact produced by the cochlear implant. Here, we describe how DC artifact removal can corrupt the response waveform and how the appropriate choice of stimulus duration may minimize this corruption. Event-related potentials were recorded to a synthesized vowel /a/ with a 170- or 400-ms duration. The P2 response, which occurs between 150 and 250 ms, was corrupted by the DC artifact removal algorithm for a 170-ms stimulus duration but was relatively uncorrupted for a 400-ms stimulus duration. To avoid response waveform corruption from DC artifact removal, one should choose a stimulus duration such that the offset of the stimulus does not temporally coincide with the specific peak of interest. While our data have been analyzed with only one specific algorithm, we argue that the length of the stimulus may be a critical factor for any DC artifact removal algorithm.

  11. Event-related delta, theta, alpha and gamma correlates to auditory oddball processing during Vipassana meditation

    Science.gov (United States)

    Delorme, Arnaud; Polich, John

    2013-01-01

    Long-term Vipassana meditators sat in meditation vs. a control (instructed mind wandering) states for 25 min, electroencephalography (EEG) was recorded and condition order counterbalanced. For the last 4 min, a three-stimulus auditory oddball series was presented during both meditation and control periods through headphones and no task imposed. Time-frequency analysis demonstrated that meditation relative to the control condition evinced decreased evoked delta (2–4 Hz) power to distracter stimuli concomitantly with a greater event-related reduction of late (500–900 ms) alpha-1 (8–10 Hz) activity, which indexed altered dynamics of attentional engagement to distracters. Additionally, standard stimuli were associated with increased early event-related alpha phase synchrony (inter-trial coherence) and evoked theta (4–8 Hz) phase synchrony, suggesting enhanced processing of the habituated standard background stimuli. Finally, during meditation, there was a greater differential early-evoked gamma power to the different stimulus classes. Correlation analysis indicated that this effect stemmed from a meditation state-related increase in early distracter-evoked gamma power and phase synchrony specific to longer-term expert practitioners. The findings suggest that Vipassana meditation evokes a brain state of enhanced perceptual clarity and decreased automated reactivity. PMID:22648958

  12. Effect of Anodal-tDCS on Event-Related Potentials: A Controlled Study

    Directory of Open Access Journals (Sweden)

    Ahmed Izzidien

    2016-01-01

    Full Text Available We aim to measure the postintervention effects of A-tDCS (anodal-tDCS on brain potentials commonly used in BCI applications, namely, Event-Related Desynchronization (ERD, Event-Related Synchronization (ERS, and P300. Ten subjects were given sham and 1.5 mA A-tDCS for 15 minutes on two separate experiments in a double-blind, randomized order. Postintervention EEG was recorded while subjects were asked to perform a spelling task based on the “oddball paradigm” while P300 power was measured. Additionally, ERD and ERS were measured while subjects performed mental motor imagery tasks. ANOVA results showed that the absolute P300 power exhibited a statistically significant difference between sham and A-tDCS when measured over channel Pz (p=0.0002. However, the difference in ERD and ERS power was found to be statistically insignificant, in controversion of the the mainstay of the litrature on the subject. The outcomes confirm the possible postintervention effect of tDCS on the P300 response. Heightening P300 response using A-tDCS may help improve the accuracy of P300 spellers for neurologically impaired subjects. Additionally, it may help the development of neurorehabilitation methods targeting the parietal lobe.

  13. Effect of Anodal-tDCS on Event-Related Potentials: A Controlled Study.

    Science.gov (United States)

    Izzidien, Ahmed; Ramaraju, Sriharasha; Roula, Mohammed Ali; McCarthy, Peter W

    2016-01-01

    We aim to measure the postintervention effects of A-tDCS (anodal-tDCS) on brain potentials commonly used in BCI applications, namely, Event-Related Desynchronization (ERD), Event-Related Synchronization (ERS), and P300. Ten subjects were given sham and 1.5 mA A-tDCS for 15 minutes on two separate experiments in a double-blind, randomized order. Postintervention EEG was recorded while subjects were asked to perform a spelling task based on the "oddball paradigm" while P300 power was measured. Additionally, ERD and ERS were measured while subjects performed mental motor imagery tasks. ANOVA results showed that the absolute P300 power exhibited a statistically significant difference between sham and A-tDCS when measured over channel Pz ( p = 0.0002). However, the difference in ERD and ERS power was found to be statistically insignificant, in controversion of the the mainstay of the litrature on the subject. The outcomes confirm the possible postintervention effect of tDCS on the P300 response. Heightening P300 response using A-tDCS may help improve the accuracy of P300 spellers for neurologically impaired subjects. Additionally, it may help the development of neurorehabilitation methods targeting the parietal lobe.

  14. Social exclusion modulates event-related frontal theta and tracks ostracism distress in children.

    Science.gov (United States)

    van Noordt, Stefon J R; White, Lars O; Wu, Jia; Mayes, Linda C; Crowley, Michael J

    2015-09-01

    Social exclusion is a potent elicitor of distress. Previous studies have shown that medial frontal theta oscillations are modulated by the experience of social exclusion. Using the Cyberball paradigm, we examined event-related dynamics of theta power in the EEG at medial frontal sites while children aged 8-12 years were exposed to conditions of fair play and social exclusion. Using an event-related design, we found that medial frontal theta oscillations (4-8Hz) increase during both early (i.e., 200-400ms) and late (i.e., 400-800ms) processing of rejection events during social exclusion relative to perceptually identical "not my turn" events during inclusion. Importantly, we show that only for the later time window (400-800ms) slow-wave theta power tracks self-reported ostracism distress. Specifically, greater theta power at medial frontal sites to "rejection" events predicted higher levels of ostracism distress. Alpha and beta oscillations for rejection events were unrelated to ostracism distress at either 200-400ms or 400-800ms time windows. Our findings extend previous studies by showing that medial frontal theta oscillations for rejection events are a neural signature of social exclusion, linked to experienced distress in middle childhood. Copyright © 2015 Elsevier Inc. All rights reserved.

  15. Event-related frontal alpha asymmetries: electrophysiological correlates of approach motivation.

    Science.gov (United States)

    Schöne, Benjamin; Schomberg, Jessica; Gruber, Thomas; Quirin, Markus

    2016-02-01

    Over the last decades, frontal alpha asymmetries observed during resting state periods of several minutes have been used as a marker of affective-motivational states. To date, there is no evidence that alpha asymmetries can be observed in response to brief affective-motivational stimuli, as typically presented in event-related designs. As we argue, frontal alpha asymmetry might indeed be elicited by brief events if they are salient enough. In an event-related design, we used erotic pictures, i.e., highly salient incentives to elicit approach motivation, and contrasted them with pictures of dressed attractive women. As expected, we found significant alpha asymmetries for erotic pictures as compared to control pictures. Our findings suggest that the highly reactive reward system can lead to immediate, phasic changes in frontal alpha asymmetries. We discuss the findings with respect to the notion that high salience of erotic pictures derives from their potential of satisfying an individuals' need by mere visual inspection, which is not the case for pictures showing other types of motivational stimuli such as food.

  16. Effects of white noise on event-related potentials in somatosensory Go/No-go paradigms.

    Science.gov (United States)

    Ohbayashi, Wakana; Kakigi, Ryusuke; Nakata, Hiroki

    2017-09-06

    Exposure to auditory white noise has been shown to facilitate human cognitive function. This phenomenon is termed stochastic resonance, and a moderate amount of auditory noise has been suggested to benefit individuals in hypodopaminergic states. The present study investigated the effects of white noise on the N140 and P300 components of event-related potentials in somatosensory Go/No-go paradigms. A Go or No-go stimulus was presented to the second or fifth digit of the left hand, respectively, at the same probability. Participants performed somatosensory Go/No-go paradigms while hearing three different white noise levels (45, 55, and 65 dB conditions). The peak amplitudes of Go-P300 and No-go-P300 in ERP waveforms were significantly larger under 55 dB than 45 and 65 dB conditions. White noise did not affect the peak latency of N140 or P300, or the peak amplitude of N140. Behavioral data for the reaction time, SD of reaction time, and error rates showed the absence of an effect by white noise. This is the first event-related potential study to show that exposure to auditory white noise at 55 dB enhanced the amplitude of P300 during Go/No-go paradigms, reflecting changes in the neural activation of response execution and inhibition processing.

  17. The impacts of racial group membership on people's distributive justice: an event-related potential study.

    Science.gov (United States)

    Wang, Yan; Tang, Yi-Yuan; Deng, Yuqin

    2014-04-16

    How individuals and societies distribute benefits has long been studied by psychologists and sociologists. Previous work has highlighted the importance of social identity on people's justice concerns. However, it is not entirely clear how racial in-group/out-group relationship affects the brain activity in distributive justice. In this study, event-related potentials were recorded while participants made their decisions about donation allocation. Behavioral results showed that racial in-group factor affected participants' decisions on justice consideration. Participants were more likely to make relatively equity decisions when racial in-group factor was congruent with equity compared with the corresponding incongruent condition. Moreover, this incongruent condition took longer response times than congruent condition. Meanwhile, less equity decisions were made when efficiency was larger in the opposite side to equity than it was equal between the two options. Scalp event-related potential analyses revealed that greater P300 and late positive potential amplitudes were elicited by the incongruent condition compared with the congruent condition. These findings suggest that the decision-making of distributive justice could be modulated by racial group membership, and greater attentional resources or cognitive efforts are required when racial in-group factor and equity conflict with each other.

  18. Hologlyphics: volumetric image synthesis performance system

    Science.gov (United States)

    Funk, Walter

    2008-02-01

    This paper describes a novel volumetric image synthesis system and artistic technique, which generate moving volumetric images in real-time, integrated with music. The system, called the Hologlyphic Funkalizer, is performance based, wherein the images and sound are controlled by a live performer, for the purposes of entertaining a live audience and creating a performance art form unique to volumetric and autostereoscopic images. While currently configured for a specific parallax barrier display, the Hologlyphic Funkalizer's architecture is completely adaptable to various volumetric and autostereoscopic display technologies. Sound is distributed through a multi-channel audio system; currently a quadraphonic speaker setup is implemented. The system controls volumetric image synthesis, production of music and spatial sound via acoustic analysis and human gestural control, using a dedicated control panel, motion sensors, and multiple musical keyboards. Music can be produced by external acoustic instruments, pre-recorded sounds or custom audio synthesis integrated with the volumetric image synthesis. Aspects of the sound can control the evolution of images and visa versa. Sounds can be associated and interact with images, for example voice synthesis can be combined with an animated volumetric mouth, where nuances of generated speech modulate the mouth's expressiveness. Different images can be sent to up to 4 separate displays. The system applies many novel volumetric special effects, and extends several film and video special effects into the volumetric realm. Extensive and various content has been developed and shown to live audiences by a live performer. Real world applications will be explored, with feedback on the human factors.

  19. Volumetric velocimetry for fluid flows

    Science.gov (United States)

    Discetti, Stefano; Coletti, Filippo

    2018-04-01

    In recent years, several techniques have been introduced that are capable of extracting 3D three-component velocity fields in fluid flows. Fast-paced developments in both hardware and processing algorithms have generated a diverse set of methods, with a growing range of applications in flow diagnostics. This has been further enriched by the increasingly marked trend of hybridization, in which the differences between techniques are fading. In this review, we carry out a survey of the prominent methods, including optical techniques and approaches based on medical imaging. An overview of each is given with an example of an application from the literature, while focusing on their respective strengths and challenges. A framework for the evaluation of velocimetry performance in terms of dynamic spatial range is discussed, along with technological trends and emerging strategies to exploit 3D data. While critical challenges still exist, these observations highlight how volumetric techniques are transforming experimental fluid mechanics, and that the possibilities they offer have just begun to be explored.

  20. De-noising with a SOCK can improve the performance of event-related ICA

    Directory of Open Access Journals (Sweden)

    Kaushik eBhaganagarapu

    2014-09-01

    Full Text Available Event-related ICA (eICA is a partially data-driven analysis method for event-related fMRI that is particularly suited to analysis of simultaneous EEG-fMRI of patients with epilepsy. EEG-fMRI studies in epileptic patients are typically analyzed using the general linear model (GLM, often with assumption that the onset and o□set of neuronal activity match EEG event onset and o□set, the neuronal activation is sustained at a constant level throughout the epileptiform event and that associated fMRI signal changes follow the canonical HRF. The eICA method allows for less constrained analyses capable of detecting early, non-canonical responses. A key step of eICA is the initial deconvolution which can be confounded by various sources of structured noise present in the fMRI signal. To help overcome this, we have extend the eICA procedure by utilizing a fully standalone and automated fMRI de-noising procedure to process the fMRI data from an EEG-fMRI acquisition prior to running eICA. Specifically we first apply ICA to the entire fMRI time-series and use a classifier to remove noise-related components. The automated objective de-noiser, Spatially Organised Component Klassificator (SOCK is used; it has previously been shown to distinguish a substantial fraction of noise from true activation, without rejecting the latter, in resting-state fMRI. A second ICA is then performed, this time on the event-related response estimates derived from the denoised data (according to the usual eICA procedure. We hypothesize that SOCK + eICA has the potential to be more sensitive than eICA alone. We test the e□effectiveness of SOCK by comparing activation obtained in an eICA analysis of EEG-fMRI data with and without the use of SOCK for 14 patients with rolandic epilepsy who exhibited stereotypical IEDs arising from a focus in the rolandic fissure.

  1. Event-related potentials to visual, auditory, and bimodal (combined auditory-visual) stimuli.

    Science.gov (United States)

    Isoğlu-Alkaç, Ummühan; Kedzior, Karina; Keskindemirci, Gonca; Ermutlu, Numan; Karamursel, Sacit

    2007-02-01

    The purpose of this study was to investigate the response properties of event related potentials to unimodal and bimodal stimulations. The amplitudes of N1 and P2 were larger during bimodal evoked potentials (BEPs) than auditory evoked potentials (AEPs) in the anterior sites and the amplitudes of P1 were larger during BEPs than VEPs especially at the parieto-occipital locations. Responses to bimodal stimulation had longer latencies than responses to unimodal stimulation. The N1 and P2 components were larger in amplitude and longer in latency during the bimodal paradigm and predominantly occurred at the anterior sites. Therefore, the current bimodal paradigm can be used to investigate the involvement and location of specific neural generators that contribute to higher processing of sensory information. Moreover, this paradigm may be a useful tool to investigate the level of sensory dysfunctions in clinical samples.

  2. Protective role of educational level on episodic memory aging: an event-related potential study.

    Science.gov (United States)

    Angel, Lucie; Fay, Séverine; Bouazzaoui, Badiâa; Baudouin, Alexia; Isingrini, Michel

    2010-12-01

    The aim of the present experiment was to investigate whether educational level could modulate the effect of aging on episodic memory and on the electrophysiological correlates of retrieval success. Participants were divided into four groups based on age (young vs. older) and educational level (high vs. low), with 14 participants in each group. Event-related potentials (ERP) were recorded while participants performed a word-stem cued-recall task. Age-related memory deficits were greater for the less educated individuals. Age differences in the ERP old/new effects were also modulated by the level of education. This study demonstrated that the effects of age on episodic memory and ERP correlates of retrieval success are smaller in participants with high educational levels than those with lower levels. These findings provide support for the reserve hypothesis and highlight the need to consider individual differences when studying cognitive and cerebral changes in aging. Copyright © 2010 Elsevier Inc. All rights reserved.

  3. The neural processing of fearful faces without attention and consciousness: an event-related potential study.

    Science.gov (United States)

    Wang, Lili; Fu, Shimin; Feng, Chunliang; Luo, Wenbo; Zhu, Xiangru; Luo, Yue-jia

    2012-01-11

    To investigate whether the non-conscious processing of fearful faces exist in unattended condition, event-related potentials (ERPs) were recorded in a facial expression detection task. Participants were asked to discriminate the facial expressions (fearful or neutral) at the attended location. Unattended faces were associated with a response that was either congruent or in conflict with the response to the attended face. ERP results showed that the trials with response conflict between attended and unattended faces enhanced the amplitude of the P3 component when the neutral face was presented at attended location and the fearful face was presented at the unattended location. Our findings imply that the non-conscious fearful faces can be processed in the unattended condition. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  4. Fractals properties of EEG during event-related desynchronization of motor imagery.

    Science.gov (United States)

    Nguyen, Ngoc Quang; Truong, Quang Dang Khoa; Kondo, Toshiyuki

    2015-01-01

    Chaos and fractal dimension are emerging modalities for the research of electroencephalogram (EEG) signal processing. The capability of measuring non-linear characteristics of the fractal dimension enables new methodologies to identify distinct brain activities. Recent studies on the topic focus on utilizing various types of fractals as features in order to design better brain state classification system. However, we have little insight about the EEG signals projected in fractal dimension. In this paper, we investigate the relationship between the non-linear characteristics of ongoing EEG signals and event-related desynchronization (ERD) during motor imagery. We observed a considerable synchronization between ERD and fractal dimension. This finding suggests further usage of chaos and fractal theory in investigating brain activities.

  5. Modulations of 'late' event-related brain potentials in humans by dynamic audiovisual speech stimuli.

    Science.gov (United States)

    Lebib, Riadh; Papo, David; Douiri, Abdel; de Bode, Stella; Gillon Dowens, Margaret; Baudonnière, Pierre-Marie

    2004-11-30

    Lipreading reliably improve speech perception during face-to-face conversation. Within the range of good dubbing, however, adults tolerate some audiovisual (AV) discrepancies and lipreading, then, can give rise to confusion. We used event-related brain potentials (ERPs) to study the perceptual strategies governing the intermodal processing of dynamic and bimodal speech stimuli, either congruently dubbed or not. Electrophysiological analyses revealed that non-coherent audiovisual dubbings modulated in amplitude an endogenous ERP component, the N300, we compared to a 'N400-like effect' reflecting the difficulty to integrate these conflicting pieces of information. This result adds further support for the existence of a cerebral system underlying 'integrative processes' lato sensu. Further studies should take advantage of this 'N400-like effect' with AV speech stimuli to open new perspectives in the domain of psycholinguistics.

  6. Event-related brain responses while listening to entire pieces of music

    DEFF Research Database (Denmark)

    Poikonen, Hanna; Alluri, Vinoo; Brattico, Elvira

    2017-01-01

    ERPs in human elicited by continuous music. The ERPs were recorded during listening to a Tango Nuevo piece, a deep techno track and an acoustic lullaby. Acoustic features related to timbre, harmony, and dynamics of the audio signal were computationally extracted from the musical pieces. Negative......Brain responses to discrete short sounds have been studied intensively using the event-related potential (ERP) method, in which the electroencephalogram (EEG) signal is divided into epochs time-locked to stimuli of interest. Here we introduce and apply a novel technique which enables one to isolate...... changes in these musical features, long phases of low values that precede a rapid increase – and that we will call Preceding Low-Feature Phases – followed by a rapid increase enhanced the amplitudes of N100 and P200 responses. These ERP responses resembled those to simpler sounds, making it possible...

  7. Spatial and Semantic Processing between Audition and Vision: An Event-Related Potential Study

    Directory of Open Access Journals (Sweden)

    Xiaoxi Chen

    2011-10-01

    Full Text Available Using a crossmodal priming paradigm, this study investigated how the brain bound the spatial and semantic features in multisensory processing. The visual stimuli (pictures of animals were presented after the auditory stimuli (sounds of animals, and the stimuli from different modalities may match spatially (or semantically or not. Participants were required to detect the head orientation of the visual target (an oddball paradigm. The event-related potentials (ERPs to the visual stimuli was enhanced by spatial attention (150–170 ms irrespectively of semantic information. The early crossmodal attention effect for the visual stimuli was more negative in the spatial-congruent condition than in the spatial-incongruent condition. By contrast, the later effects of spatial ERPs were significant only for the semantic- congruent condition (250–300 ms. These findings indicated that spatial attention modulated early visual processing, and semantic and spatial features were simultaneously used to orient attention and modulate later processing stages.

  8. Event-related Desynchronization of Mu Rhythms During Concentric and Eccentric Contractions.

    Science.gov (United States)

    Park, Joo-Hee; Cynn, Heon-Seock; Cha, Kwang Su; Kim, Kyung Hwan; Jeon, Hye-Seon

    2017-09-19

    The purpose of this study was to compare the electroencephalographic (EEG) patterns and reaction times (RTs) of muscle activation between concentric and eccentric biceps brachii contractions under the RT paradigm and to evaluate how the EEG patterns and RTs changed with practice. Sixteen subjects performed 3 sets of 30 repetitions of submaximal voluntary concentric and eccentric biceps contractions. RT, event-related desynchronization (ERD) patterns of mu rhythm onset, and ERD amplitudes were selectively analyzed. Mental demand decreased as familiarity with the motor action increased due to practice regardless of contraction type. However, the 2 types of muscle contractions still have differences in brain activity regardless of decreased mental demand: eccentric contractions require earlier preparation than concentric contractions.

  9. A comparative study of event-related coupling patterns during an auditory oddball task in schizophrenia

    Science.gov (United States)

    Bachiller, Alejandro; Poza, Jesús; Gómez, Carlos; Molina, Vicente; Suazo, Vanessa; Hornero, Roberto

    2015-02-01

    Objective. The aim of this research is to explore the coupling patterns of brain dynamics during an auditory oddball task in schizophrenia (SCH). Approach. Event-related electroencephalographic (ERP) activity was recorded from 20 SCH patients and 20 healthy controls. The coupling changes between auditory response and pre-stimulus baseline were calculated in conventional EEG frequency bands (theta, alpha, beta-1, beta-2 and gamma), using three coupling measures: coherence, phase-locking value and Euclidean distance. Main results. Our results showed a statistically significant increase from baseline to response in theta coupling and a statistically significant decrease in beta-2 coupling in controls. No statistically significant changes were observed in SCH patients. Significance. Our findings support the aberrant salience hypothesis, since SCH patients failed to change their coupling dynamics between stimulus response and baseline when performing an auditory cognitive task. This result may reflect an impaired communication among neural areas, which may be related to abnormal cognitive functions.

  10. Neuroprotection against vascular dementia after acupuncture combined with donepezil hydrochloride: P300 event related potential

    Directory of Open Access Journals (Sweden)

    Qiang Liu

    2016-01-01

    Full Text Available Acupuncture can be used to treat various nervous system diseases. Here, 168 vascular dementia patients were orally administered donepezil hydrochloride alone (5 mg/day, once a day for 56 days, or combined with acupuncture at Shenting (DU24, Tianzhu (BL10, Sishencong (Extra, Yintang (Extra, Renzhong (DU26, Neiguan (PC6, Shenmen (HT7, Fengchi (GB20, Wangu (GB12 and Baihui (DU20 (once a day for 56 days. Compared with donepezil hydrochloride alone, P300 event related potential latency was shorter with an increased amplitude in patients treated with donepezil hydrochloride and acupuncture. Mini-Mental State Examination score was also higher. Moreover, these differences in P300 latency were identified within different infarcted regions in patients treated with donepezil hydrochloride and acupuncture. These findings indicate that acupuncture combined with donepezil hydrochloride noticeably improves cognitive function in patients with vascular dementia, and exerts neuroprotective effects against vascular dementia.

  11. The delay effect on outcome evaluation: results from an Event-related Potential study

    Directory of Open Access Journals (Sweden)

    Chen eQu

    2013-11-01

    Full Text Available Behavioral studies demonstrate that the timing of receiving gains or losses affects decision-making, a phenomenon known as temporal discounting, as participants are inclined to prefer immediate rewards over delayed ones and vice versa for losses. The present study used the event-related potential (ERP technique with a simple gambling task to investigate how delayed rewards and losses affected the brain activity in outcome evaluations made by 20 young adults. Statistical analysis revealed a larger feedback related negativity (FRN effect between loss and gain following immediate outcomes than following future outcomes. In addition, delay impacted FRN only in gain conditions, with delayed winning eliciting a more negative FRN than immediatewinning. These results suggest that temporal discounting and sign effect could be encoded in the FRN in the early stage of outcome evaluation.

  12. Self-relevant beauty evaluation: Evidence from an event-related potentials study.

    Science.gov (United States)

    Kong, Fanchang; Zhang, Yan; Tian, Yuan; Fan, Cuiying; Zhou, Zongkui

    2015-03-01

    This study examines the electrophysiological correlates of beauty evaluation when participants performed the self-reference task. About 13 (7 men, 6 women) undergraduates participated in the experiment using event-related potentials. Results showed that the response to self-relevant information was faster compared to other-relevant information and no significant differences for self-relevant relative to mother-relevant information were observed. Both physical and interior beauty words for self-relevant information showed an enhanced late positive component as compared to other-relevant information. Physical beauty for self-relevant information yielded a larger late positive component in contrast to mother-relevant information but not for interior beauty. This study indicates that beauty is specific to the person who judges it though an individual and one's mother may hold similar views of interior beauty.

  13. Event-related potential evidence suggesting voters remember political events that never happened.

    Science.gov (United States)

    Coronel, Jason C; Federmeier, Kara D; Gonsalves, Brian D

    2014-03-01

    Voters tend to misattribute issue positions to political candidates that are consistent with their partisan affiliation, even though these candidates have never explicitly stated or endorsed such stances. The prevailing explanation in political science is that voters misattribute candidates' issue positions because they use their political knowledge to make educated but incorrect guesses. We suggest that voter errors can also stem from a different source: false memories. The current study examined event-related potential (ERP) responses to misattributed and accurately remembered candidate issue information. We report here that ERP responses to misattributed information can elicit memory signals similar to that of correctly remembered old information--a pattern consistent with a false memory rather than educated guessing interpretation of these misattributions. These results suggest that some types of voter misinformation about candidates may be harder to correct than previously thought.

  14. Aesthetic appreciation: event-related field and time-frequency analyses.

    Science.gov (United States)

    Munar, Enric; Nadal, Marcos; Castellanos, Nazareth P; Flexas, Albert; Maestú, Fernando; Mirasso, Claudio; Cela-Conde, Camilo J

    2011-01-01

    Improvements in neuroimaging methods have afforded significant advances in our knowledge of the cognitive and neural foundations of aesthetic appreciation. We used magnetoencephalography (MEG) to register brain activity while participants decided about the beauty of visual stimuli. The data were analyzed with event-related field (ERF) and Time-Frequency (TF) procedures. ERFs revealed no significant differences between brain activity related with stimuli rated as "beautiful" and "not beautiful." TF analysis showed clear differences between both conditions 400 ms after stimulus onset. Oscillatory power was greater for stimuli rated as "beautiful" than those regarded as "not beautiful" in the four frequency bands (theta, alpha, beta, and gamma). These results are interpreted in the frame of synchronization studies.

  15. An event-related potential study of supramodal attentional control and crossmodal attention effects.

    Science.gov (United States)

    Green, Jessica J; McDonald, John J

    2006-03-01

    We conducted two audiovisual experiments to determine whether event-related potential (ERP) components elicited by attention-directing cues reflect supramodal attentional control. Symbolic visual cues were used to direct attention prior to auditory targets in Experiment 1, and symbolic auditory cues were used to direct attention prior to visual targets in Experiment 2. Different patterns of cue ERPs were found in the two experiments. A frontal negativity called the ADAN was absent in Experiment 2, which indicates that this component does not reflect supramodal attentional control. A posterior positivity called the LDAP was observed in both experiments but was focused more posteriorly over the occipital scalp in Experiment 2. This component appears to reflect multiple processes, including visual processes involved in location marking and target preparation as well as supramodal processes involved in attentional control.

  16. Cognitive function and event-related potentials in children with type 1 diabetes mellitus.

    Science.gov (United States)

    Shehata, Ghaydaa; Eltayeb, Azza

    2010-04-01

    Type 1 diabetes mellitus is associated with cognitive changes, but the extent of cognition decline depends on age at onset, duration of diabetes, and occurrence of attacks of hypoglycemia or ketoacidosis. This study was designed to assess cognitive function in a group of children with type 1 diabetes mellitus. A total of 40 diabetic children were recruited from the pediatric department of Assiut University Hospital, Egypt. Forty healthy children matched for age, sex, and socioeconomic status were chosen as controls for comparison. Cognition was assessed using Stanford-Binet and event-related potentials tests. Compared to the control group, patients reported a significant reduction in intelligent quotient, comprehension, abstract visual reasoning, quantitative reasoning, bead memory, and total short memory testing for cognitive functions. Prolonged N1, P200, N2, and P300 latencies and reduced P300-N2 amplitude were reported. Significant negative correlations were identified in most studied cognitive functions and ketoacidosis or family history of diabetes mellitus.

  17. P300 component of event-related potentials in persons with asperger disorder.

    Science.gov (United States)

    Iwanami, Akira; Okajima, Yuka; Ota, Haruhisa; Tani, Masayuki; Yamada, Takashi; Yamagata, Bun; Hashimoto, Ryuichiro; Kanai, Chieko; Takashio, Osamu; Inamoto, Atsuko; Ono, Taisei; Takayama, Yukiko; Kato, Nobumasa

    2014-10-01

    In the present study, we investigated auditory event-related potentials in adults with Asperger disorder and normal controls using an auditory oddball task and a novelty oddball task. Task performance and the latencies of P300 evoked by both target and novel stimuli in the two tasks did not differ between the two groups. Analysis of variance revealed that there was a significant interaction effect between group and electrode site on the mean amplitude of the P300 evoked by novel stimuli, which indicated that there was an altered distribution of the P300 in persons with Asperger disorder. In contrast, there was no significant interaction effect on the mean P300 amplitude elicited by target stimuli. Considering that P300 comprises two main subcomponents, frontal-central-dominant P3a and parietal-dominant P3b, our results suggested that persons with Asperger disorder have enhanced amplitude of P3a, which indicated activated prefrontal function in this task.

  18. Effects of context on implicit and explicit lexical knowledge: an event-related potential study.

    Science.gov (United States)

    Choi, Sungmook; Kim, Jingu; Ryu, Kwangmin

    2014-10-01

    Although much is known about how contextualized and decontextualized learning affects explicit lexical knowledge, how these learning conditions contribute to implicit lexical knowledge remains unclear. To address this problem, Korean high school students were instructed to learn 30 English words by reading meaningful passages (i.e., in context) and another 30 English words using a wordlist (i.e., out of context). Five weeks later, implicit lexical knowledge was gauged by reaction time and the N400 event-related brain potential component, and explicit lexical knowledge was assessed with an explicit behavioral measure. Results showed that neither learning type was superior to the other in terms of implicit lexical knowledge acquisition, whereas learning words out of context was more effective than learning words in context for establishing explicit lexical knowledge. These results suggest that the presence or absence of context may lead to dissociation in the development of implicit and explicit lexical knowledge. Copyright © 2014 Elsevier Ltd. All rights reserved.

  19. Crossmodal effects of Guqin and piano music on selective attention: an event-related potential study.

    Science.gov (United States)

    Zhu, Weina; Zhang, Junjun; Ding, Xiaojun; Zhou, Changle; Ma, Yuanye; Xu, Dan

    2009-11-27

    To compare the effects of music from different cultural environments (Guqin: Chinese music; piano: Western music) on crossmodal selective attention, behavioral and event-related potential (ERP) data in a standard two-stimulus visual oddball task were recorded from Chinese subjects in three conditions: silence, Guqin music or piano music background. Visual task data were then compared with auditory task data collected previously. In contrast with the results of the auditory task, the early (N1) and late (P300) stages exhibited no differences between Guqin and piano backgrounds during the visual task. Taking our previous study and this study together, we can conclude that: although the cultural-familiar music influenced selective attention both in the early and late stages, these effects appeared only within a sensory modality (auditory) but not in cross-sensory modalities (visual). Thus, the musical cultural factor is more obvious in intramodal than in crossmodal selective attention.

  20. Conveying the concept of movement in music: An event-related brain potential study.

    Science.gov (United States)

    Zhou, Linshu; Jiang, Cunmei; Wu, Yingying; Yang, Yufang

    2015-10-01

    This study on event-related brain potential investigated whether music can convey the concept of movement. Using a semantic priming paradigm, natural musical excerpts were presented to non-musicians, followed by semantically congruent or incongruent pictures that depicted objects either in motion or at rest. The priming effects were tested in object decision and implicit recognition tasks to distinguish the effects of automatic conceptual activation from response competition. Results showed that in both tasks, pictures that were incongruent to preceding musical excerpts elicited larger N400 than congruent pictures, suggesting that music can prime the representations of movement concepts. Results of the multiple regression analysis showed that movement expression could be well predicted by specific acoustic and musical features, indicating the associations between music per se and the processing of iconic musical meaning. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. Attentional Selection Accompanied by Eye Vergence as Revealed by Event-Related Brain Potentials.

    Directory of Open Access Journals (Sweden)

    Maria Sole Puig

    Full Text Available Neural mechanisms of attention allow selective sensory information processing. Top-down deployment of visual-spatial attention is conveyed by cortical feedback connections from frontal regions to lower sensory areas modulating late stimulus responses. A recent study reported the occurrence of small eye vergence during orienting top-down attention. Here we assessed a possible link between vergence and attention by comparing visual event related potentials (vERPs to a cue stimulus that induced attention to shift towards the target location to the vERPs to a no-cue stimulus that did not trigger orienting attention. The results replicate the findings of eye vergence responses during orienting attention and show that the strength and time of eye vergence coincide with the onset and strength of the vERPs when subjects oriented attention. Our findings therefore support the idea that eye vergence relates to and possibly has a role in attentional selection.

  2. Event-related potential study of frontal activity during imagination of rhythm.

    Science.gov (United States)

    Jomori, Izumi; Uemura, Jun-ichi; Nakagawa, Yoshiro; Hoshiyama, Minoru

    2011-12-01

    In 11 healthy volunteers, we used event-related potentials (ERP) to investigate the frontal activity associated with imagining a beat. In imagery sessions, subjects were asked to imagine a rhythm during a silent recording period following a series of guide sounds played at 1 Hz. In control sessions, subjects were asked to imagine a vowel sound ("a") continuously during the silent recording period. In eight subjects, relative negative potentials were recorded during imagery sessions (compared with potentials in control sessions), with timing that was similar to that of the guide sounds. Activity in the left frontal region was more significant than that in other areas during beat imagination. These data indicate that a semantic strategy for simple rhythm imagery might involve temporary phasic activation in the left frontal area, although rhythm production and perception might be generated in the right side, as reported in previous studies. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Correlation between event-related potentials and MR measurements in chronic alcoholic patients

    International Nuclear Information System (INIS)

    Kaseda, Yumiko; Miyazato, Yoshikazu; Ogura, Chikara; Nakamoto, Haruo; Uema, Takeshi; Yamamoto, Kazuyoshi; Ohta, Ikuya

    1994-01-01

    Event-related potentials were recorded in 25 abstinent alcoholics, and 25 gender- and age-matched controls during a two-tone discrimination (odd ball) task. All the subjects were free from medication and dextral. MR images were examined in the alcoholics. The amplitudes of N100, N200 and P300 in the alcoholics were reduced compared with those of the controls. In order to identify morphological changes responsible for ERP abnormalities, linear regression analyses were performed between ERP measures and MRI parameters. The amplitude of N100 was inversely correlated with ventricular size. The amplitudes of P300 were inversely correlated with both ventricular size and width of cortical sulci. It was suggested that the N100 abnormality was related to subcortical structure, and P300 alteration was related to both subcortical and cortical structures in the alcoholics. (author)

  4. The correlation between motor impairments and event-related desynchronization during motor imagery in ALS patients

    Directory of Open Access Journals (Sweden)

    Kasahara Takashi

    2012-06-01

    Full Text Available Abstract Background The event-related desynchronization (ERD in EEG is known to appear during motor imagery, and is thought to reflect cortical processing for motor preparation. The aim of this study is to examine the modulation of ERD with motor impairment in ALS patients. ERD during hand motor imagery was obtained from 8 ALS patients with a variety of motor impairments. ERD was also obtained from age-matched 11 healthy control subjects with the same motor task. The magnitude and frequency of ERD were compared between groups for characterization of ALS specific changes. Results The ERD of ALS patients were significantly smaller than those of control subjects. Bulbar function and ERD were negatively correlated in ALS patients. Motor function of the upper extremities did was uncorrelated with ERD. Conclusions ALS patients with worsened bulbar scales may show smaller ERD. Motor function of the upper extremities did was uncorrelated with ERD.

  5. Human event-related brain potentials to auditory periodic noise stimuli.

    Science.gov (United States)

    Kaernbach, C; Schröger, E; Gunter, T C

    1998-02-06

    Periodic noise is perceived as different from ordinary non-repeating noise due to the involvement of echoic memory. Since this stimulus does not contain simple physical cues (such as onsets or spectral shape) that might obscure sensory memory interpretations, it is a valuable tool to study sensory memory functions. We demonstrated for the first time that the processing of periodic noise can be tapped by event-related brain potentials (ERPs). Human subjects received repeating segments of noise embedded in non-repeating noise. They were instructed to detect the periodicity inherent to the stimulation. We observed a central negativity time-locked on the periodic segment that correlated to the subjects behavioral performance in periodicity detection. It is argued that the ERP result indicates an enhancement of sensory-specific processing.

  6. Event-related brain potentials reflect traces of echoic memory in humans.

    Science.gov (United States)

    Winkler, I; Reinikainen, K; Näätänen, R

    1993-04-01

    In sequences of identical auditory stimuli, infrequent deviant stimuli elicit an event-related brain potential component called mismatch negativity (MMN). MMN is presumed to reflect the existence of a memory trace of the frequent stimulus at the moment of presentation of the infrequent stimulus. This hypothesis was tested by applying the recognition-masking paradigm of cognitive psychology. In this paradigm, a masking sound presented shortly before or after a test stimulus diminishes the recognition memory of this stimulus, the more so the shorter the interval between the test and masking stimuli. This interval was varied in the present study. It was found that the MMN amplitude strongly correlated with the subject's ability to discriminate between frequent and infrequent stimuli. This result strongly suggests that MMN provides a measure for a trace of sensory memory, and further, that with MMN, this memory can be studied without performance-related distortions.

  7. Bilingualism and increased attention to speech: Evidence from event-related potentials.

    Science.gov (United States)

    Kuipers, Jan Rouke; Thierry, Guillaume

    2015-10-01

    A number of studies have shown that from an early age, bilinguals outperform their monolingual peers on executive control tasks. We previously found that bilingual children and adults also display greater attention to unexpected language switches within speech. Here, we investigated the effect of a bilingual upbringing on speech perception in one language. We recorded monolingual and bilingual toddlers' event-related potentials (ERPs) to spoken words preceded by pictures. Words matching the picture prime elicited an early frontal positivity in bilingual participants only, whereas later ERP amplitudes associated with semantic processing did not differ between groups. These results add to the growing body of evidence that bilingualism increases overall attention during speech perception whilst semantic integration is unaffected. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  8. Multiple sources of positive- and negative-priming effects: an event-related potential study.

    Science.gov (United States)

    Gibbons, Henning; Rammsayer, Thomas H; Stahl, Jutta

    2006-01-01

    Event-related potential correlates of positive priming (PP) and negative priming (NP) were investigated in order to further elucidate the cognitive mechanisms involved. Thirty-six participants performed both an identity- and a location-based priming task. Repeating the target stimulus/location from the immediately preceding display produced behavioral PP. With localization, but not with identification, behavioral NP was observed when the target stimulus/location matched the preceding distractor stimulus/location. Smaller P300 amplitude accompanied identity-based PP, suggesting persisting target-specific activation. The lateralized readiness potential, an index of correct/incorrect response activation, indicated persisting central motor activation as another source of PP. Both location-based PP and NP were accompanied by reduced P1/N1 and P300 amplitudes, pointing to the involvement of inhibition of return in location-based priming. The results support the view that multiple brain processes underlie behavioral priming.

  9. Additive effects of repetition and predictability during comprehension: evidence from event-related potentials.

    Directory of Open Access Journals (Sweden)

    Wing-Yee Chow

    Full Text Available Previous research has shown that neural responses to words during sentence comprehension are sensitive to both lexical repetition and a word's predictability in context. While previous research has often contrasted the effects of these variables (e.g. by looking at cases in which word repetition violates sentence-level constraints, little is known about how they work in tandem. In the current study we examine how recent exposure to a word and its predictability in context combine to impact lexical semantic processing. We devise a novel paradigm that combines reading comprehension with a recognition memory task, allowing for an orthogonal manipulation of a word's predictability and its repetition status. Using event-related brain potentials (ERPs, we show that word repetition and predictability have qualitatively similar and additive effects on the N400 amplitude. We propose that prior exposure to a word and predictability impact lexical semantic processing in an additive and independent fashion.

  10. Attentional Selection Accompanied by Eye Vergence as Revealed by Event-Related Brain Potentials.

    Science.gov (United States)

    Sole Puig, Maria; Pallarés, Josep Marco; Perez Zapata, Laura; Puigcerver, Laura; Cañete, Josep; Supèr, Hans

    2016-01-01

    Neural mechanisms of attention allow selective sensory information processing. Top-down deployment of visual-spatial attention is conveyed by cortical feedback connections from frontal regions to lower sensory areas modulating late stimulus responses. A recent study reported the occurrence of small eye vergence during orienting top-down attention. Here we assessed a possible link between vergence and attention by comparing visual event related potentials (vERPs) to a cue stimulus that induced attention to shift towards the target location to the vERPs to a no-cue stimulus that did not trigger orienting attention. The results replicate the findings of eye vergence responses during orienting attention and show that the strength and time of eye vergence coincide with the onset and strength of the vERPs when subjects oriented attention. Our findings therefore support the idea that eye vergence relates to and possibly has a role in attentional selection.

  11. Processing of emotional faces in congenital amusia: An emotional music priming event-related potential study.

    Science.gov (United States)

    Zhishuai, Jin; Hong, Liu; Daxing, Wu; Pin, Zhang; Xuejing, Lu

    2017-01-01

    Congenital amusia is characterized by lifelong impairments in music perception and processing. It is unclear whether pitch detection deficits impact amusic individuals' perception of musical emotion. In the current work, 19 amusics and 21 healthy controls were subjected to electroencephalography (EEG) while being exposed to music excerpts and emotional faces. We assessed each individual's ability to discriminate positive- and negative-valenced emotional faces and analyzed electrophysiological indices, in the form of event-related potentials (ERPs) recorded at 32 sites, following exposure to emotionally positive or negative music excerpts. We observed smaller N2 amplitudes in response to facial expressions in the amusia group than in the control group, suggesting that amusics were less affected by the musical stimuli. The late-positive component (LPC) in amusics was similar to that in controls. Our results suggest that the neurocognitive deficit characteristic of congenital amusia is fundamentally an impairment in musical information processing rather than an impairment in emotional processing.

  12. Processing of emotional faces in congenital amusia: An emotional music priming event-related potential study

    Directory of Open Access Journals (Sweden)

    Jin Zhishuai

    2017-01-01

    Full Text Available Congenital amusia is characterized by lifelong impairments in music perception and processing. It is unclear whether pitch detection deficits impact amusic individuals' perception of musical emotion. In the current work, 19 amusics and 21 healthy controls were subjected to electroencephalography (EEG while being exposed to music excerpts and emotional faces. We assessed each individual's ability to discriminate positive- and negative-valenced emotional faces and analyzed electrophysiological indices, in the form of event-related potentials (ERPs recorded at 32 sites, following exposure to emotionally positive or negative music excerpts. We observed smaller N2 amplitudes in response to facial expressions in the amusia group than in the control group, suggesting that amusics were less affected by the musical stimuli. The late-positive component (LPC in amusics was similar to that in controls. Our results suggest that the neurocognitive deficit characteristic of congenital amusia is fundamentally an impairment in musical information processing rather than an impairment in emotional processing.

  13. Information structure influences depth of syntactic processing: event-related potential evidence for the Chomsky illusion.

    Science.gov (United States)

    Wang, Lin; Bastiaansen, Marcel; Yang, Yufang; Hagoort, Peter

    2012-01-01

    Information structure facilitates communication between interlocutors by highlighting relevant information. It has previously been shown that information structure modulates the depth of semantic processing. Here we used event-related potentials to investigate whether information structure can modulate the depth of syntactic processing. In question-answer pairs, subtle (number agreement) or salient (phrase structure) syntactic violations were placed either in focus or out of focus through information structure marking. P600 effects to these violations reflect the depth of syntactic processing. For subtle violations, a P600 effect was observed in the focus condition, but not in the non-focus condition. For salient violations, comparable P600 effects were found in both conditions. These results indicate that information structure can modulate the depth of syntactic processing, but that this effect depends on the salience of the information. When subtle violations are not in focus, they are processed less elaborately. We label this phenomenon the Chomsky illusion.

  14. Auditory event-related responses to diphthongs in different attention conditions

    DEFF Research Database (Denmark)

    Morris, David Jackson; Steinmetzger, Kurt; Tøndering, John

    2016-01-01

    (i) attended to the auditory stimuli, (ii) ignored the auditory stimuli and watched a film, and (iii) diverted their attention to a visual discrimination task. Responses elicited by diphthongs where F2 values rose and fell were found to be different and this precluded their combined analysis......The modulation of auditory event-related potentials (ERP) by attention generally results in larger amplitudes when stimuli are attended. We measured the P1-N1-P2 acoustic change complex elicited with synthetic overt (second formant, F2 = 1000 Hz) and subtle (F2 = 100 Hz) diphthongs, while subjects...... quality transitions, even when the attention of a subject is diverted to an unrelated visual task....

  15. A new method for detecting interactions between the senses in event-related potentials

    DEFF Research Database (Denmark)

    Gondan, Matthias; Röder, B.

    2006-01-01

    Event-related potentials (ERPs) can be used in multisensory research to determine the point in time when different senses start to interact, for example, the auditory and the visual system. For this purpose, the ERP to bimodal stimuli (AV) is often compared to the sum of the ERPs to auditory (A......) and visual (V) stimuli: AV - (A + V). If the result is non-zero, this is interpreted as an indicator for multisensory interactions. Using this method, several studies have demonstrated auditory-visual interactions as early as 50 ms after stimulus onset. The subtraction requires that A, V, and AV do...... not contain common activity: This activity would be subtracted twice from one ERP and would, therefore, contaminate the result. In the present study, ERPs to unimodal, bimodal, and trimodal auditory, visual, and tactile stimuli (T) were recorded. We demonstrate that (T + TAV) - (TA + TV) is equivalent to AV...

  16. Event-related brain potential evidence for animacy processing asymmetries during sentence comprehension.

    Science.gov (United States)

    Nieuwland, Mante S; Martin, Andrea E; Carreiras, Manuel

    2013-08-01

    The animacy distinction is deeply rooted in the language faculty. A key example is differential object marking, the phenomenon where animate sentential objects receive specific marking. We used event-related potentials to examine the neural processing consequences of case-marking violations on animate and inanimate direct objects in Spanish. Inanimate objects with incorrect prepositional case marker 'a' ('al suelo') elicited a P600 effect compared to unmarked objects, consistent with previous literature. However, animate objects without the required prepositional case marker ('el obispo') only elicited an N400 effect compared to marked objects. This novel finding, an exclusive N400 modulation by a straightforward grammatical rule violation, does not follow from extant neurocognitive models of sentence processing, and mirrors unexpected "semantic P600" effects for thematically problematic sentences. These results may reflect animacy asymmetry in competition for argument prominence: following the article, thematic interpretation difficulties are elicited only by unexpectedly animate objects. Copyright © 2013 Elsevier Inc. All rights reserved.

  17. Pharmacodynamic Modelling of Placebo and Buprenorphine Effects on Event-Related Potentials in Experimental Pain

    DEFF Research Database (Denmark)

    Juul, Rasmus V; Foster, David J R; Upton, Richard N

    2014-01-01

    The purpose of the study was to investigate placebo and buprenorphine effects on event-related potentials (ERPs) in experimental pain and the potential benefit of population pharmacodynamic modelling in data analysis. Nineteen healthy volunteers received transdermal placebo and buprenorphine...... in a cross-over study. Drug plasma concentrations and ERPs after electrical stimulation at the median nerve with intensity adjusted to pain detection threshold were recorded until 144 hrs after administration. Placebo and concentration-effect models were fitted to data using non-linear mixed-effects...... modelling implemented in NONMEM (V7.2.0.). Pharmacodynamic models were developed to adequately describe both placebo and buprenorphine ERP data. Models predicted significant placebo effects, but did not predict significant effects related to buprenorphine concentration. Models revealed that ERPs varied both...

  18. Effects of rearranged vision on event-related lateralizations of the EEG during pointing.

    Science.gov (United States)

    Berndt, Isabelle; Franz, Volker H; Bülthoff, Heinrich H; Gotz, Karl G; Wascher, Edmund

    2005-01-01

    We used event-related lateralizations of the EEG (ERLs) and reversed vision to study visuomotor processing with conflicting proprioceptive and visual information during pointing. Reversed vision decreased arm-related lateralization, probably reflecting the simultaneous activity of left and right arm specific neurons: neurons in the hemisphere contralateral to the observed action were probably activated by visual feedback, neurons in the hemisphere contralateral to the response side by the somatomotor feedback. Lateralization related to the target in parietal cortex increased, indicating that visual to motor transformation in parietal cortex required additional time and resources with reversed vision. A short period of adaptation to an additional lateral displacement of the visual field increased arm-contralateral activity in parietal cortex during the movement. This is in agreement with the, which showed that adaptation to a lateral displacement of the visual field is reflected in increased parietal involvement during pointing.

  19. The impact of transcranial magnetic stimulation on cognitive processing: an event-related potential study.

    Science.gov (United States)

    Evers, S; Böckermann, I; Nyhuis, P W

    2001-09-17

    Several neuropsychological studies have shown that repetitive transcranial magnetic stimulation (rTMS) can improve cognitive processing. We performed a study on the impact of rTMS on cognitive processing as measured by a neurophysiological method. In 14 healthy subjects, visually evoked event-related potentials (ERP) and mean choice reaction time were measured before and after 20 Hz rTMS of the left and of the right prefrontal cortex. The data were compared to sham stimulation and to 1 Hz single TMS. P3 latencies and reaction time were significantly decreased by rTMS of the left but not of the right prefrontal cortex, single TMS did not have any significant impact on the ERP components. We conclude that the facilitating effects of rTMS on cognitive processing can be proven even by objective neurophysiological measures.

  20. Why Students Fail at Volumetric Analysis.

    Science.gov (United States)

    Pickering, Miles

    1979-01-01

    Investigates the reasons for students' failure in an introductory volumetric analysis course by analyzing test papers and judging them against a hypothetical ideal method of grading laboratory techniques. (GA)

  1. Adverse Health Events Related to Self-Medication Practices Among Elderly: A Systematic Review.

    Science.gov (United States)

    Locquet, Médéa; Honvo, Germain; Rabenda, Véronique; Van Hees, Thierry; Petermans, Jean; Reginster, Jean-Yves; Bruyère, Olivier

    2017-05-01

    Older adults often resort to self-medication to relieve symptoms of their current illnesses; however, the risks of this practice are multiplied in old age. In particular, this age group is more vulnerable to adverse drug events because of the physiological changes that occur due to senescence. The aim of the study was to obtain an overview of the adverse health events related to self-medication among subjects aged 60 years and over through a systematic review of the literature. A study of relevant articles was conducted among databases (MEDLINE, PsycINFO, and EBM Reviews-Cochrane Database of Systematic Reviews). Eligibility criteria were established and applied by two investigators to include suitable studies. The results and outcomes of interest were detailed in a descriptive report. The electronic search identified 4096 references, and the full texts of 74 were reviewed, of which four were retained in the analysis: three had a cross-sectional design and one prospectively followed elderly subjects. The first study showed a 26.7% prevalence of adverse drug reactions (ADRs) among elders, the second study found a 75% prevalence of side effects, and, finally, a prospective study showed an ADR incidence of 4.5% among self-medicated elders. These studies showed that adverse health events related to self-medication are relatively frequently reported. They also highlighted that analgesics and anti-inflammatory drugs are the most self-medicated products, while vitamins and dietary supplements also appear to be frequently self-administered, but by older individuals. Studies on self-medication in the elderly and its adverse health effects are clearly lacking. There is a need to perform prospective studies on this topic to gain a clear understanding of the extent of this problem and to enhance the awareness of health professionals to better inform seniors.

  2. Self-Referential Processing in Adolescents: Stability of Behavioral and Event-Related Potential Markers

    Science.gov (United States)

    Auerbach, Randy P.; Bondy, Erin; Stanton, Colin H.; Webb, Christian A.; Shankman, Stewart A.; Pizzagalli, Diego A.

    2016-01-01

    The self-referential encoding task (SRET)—an implicit measure of self-schema—has been used widely to probe cognitive biases associated with depression, including among adolescents. However, research testing the stability of behavioral and electrocortical effects is sparse. Therefore, the current study sought to evaluate the stability of behavioral markers and event-related potentials (ERP) elicited from the SRET over time in healthy, female adolescents (n = 31). At baseline, participants were administered a diagnostic interview and a self-report measure of depression severity. In addition, they completed the SRET while 128-channel event-related potential (ERP) data were recorded to examine early (P1) and late (late positive potential [LPP]) ERPs. Three months later, participants were re-administered the depression self-report measure and the SRET in conjunction with ERPs. Results revealed that healthy adolescents endorsed, recalled, and recognized more positive and fewer negative words at each assessment, and these effects were stable over time (rs = 0.44–0.83). Similarly, they reported a faster reaction time when endorsing self-relevant positive words, as opposed to negative words, at both the initial and follow-up assessment (r = 0.82). Second, ERP responses, specifically potentiated P1 and late LPP positivity to positive versus negative words, were consistent over time (rs = 0.56–0.83), and the internal reliability of ERPs were robust at each time point (rs = 0.52–0.80). As a whole, these medium-to-large effects suggest that the SRET is a reliable behavioral and neural probe of self-referential processing. PMID:27302282

  3. [Differential effects of attention deficit/hyperactivity disorder subtypes in event-related potentials].

    Science.gov (United States)

    Tamayo-Orrego, Lukas; Osorio Forero, Alejandro; Quintero Giraldo, Lina Paola; Parra Sánchez, José Hernán; Varela, Vilma; Restrepo, Francia

    2015-01-01

    To better understand the neurophysiological substrates in attention deficit/hyperactivity disorder (ADHD), a study was performed on of event-related potentials (ERPs) in Colombian patients with inattentive and combined ADHD. A case-control, cross-sectional study was designed. The sample was composed of 180 subjects between 5 and 15 years of age (mean, 9.25±2.6), from local schools in Manizales. The sample was divided equally in ADHD or control groups and the subjects were paired by age and gender. The diagnosis was made using the DSM-IV-TR criteria, the Conners and WISC-III test, a psychiatric interview (MINIKID), and a medical evaluation. ERPs were recorded in a visual and auditory passive oddball paradigm. Latency and amplitude of N100, N200 and P300 components for common and rare stimuli were used for statistical comparisons. ADHD subjects show differences in the N200 amplitude and P300 latency in the auditory task. The N200 amplitude was reduced in response to visual stimuli. ADHD subjects with combined symptoms show a delayed P300 in response to auditory stimuli, whereas inattentive subjects exhibited differences in the amplitude of N100 and N200. Combined ADHD patients showed longer N100 latency and smaller N200-P300 amplitude compared to inattentive ADHD subjects. The results show differences in the event-related potentials between combined and inattentive ADHD subjects. Copyright © 2014 Asociación Colombiana de Psiquiatría. Publicado por Elsevier España. All rights reserved.

  4. Best Practices for Event-Related Potential Research in Clinical Populations.

    Science.gov (United States)

    Kappenman, Emily S; Luck, Steven J

    2016-03-01

    The event-related potential (ERP) technique has been used for decades to answer important questions about sensory, cognitive, motor, and emotion-related processes in clinical disorders. However, ERP research with clinical populations often involves unique challenges above and beyond the general issues involved in conducting ERP studies in typical research participants. The goal of this paper is to provide an overview of the common challenges that arise in ERP research with clinical populations, including issues in experimental design, recording, analysis, and interpretation of ERPs. In addition, we provide strategies that have proven effective in each of these areas for maximizing the potential of the ERP technique to provide important insights about clinical disorders. The event-related potential (ERP) technique has been used for decades to assess sensory, cognitive, motor, and emotion-related processes in individuals with clinical disorders, and it has great promise for yielding new insights in the future. However, many complex methodological challenges arise in applying this technique to clinical populations, and these challenges must be overcome for the ERP technique to live up to its potential. The goal of this paper is to describe some of the most salient challenges and provide effective strategies for dealing with them. Our own experience has been mainly in schizophrenia, but much of the information presented here applies to any clinical population. We focus our discussion on traditional approaches to ERPs, for which methods been refined over many decades. Information about newer approaches, such as time-frequency analysis, can be found elsewhere (1; 2). We begin with a brief overview of the ERP technique, followed by a discussion of the challenges in designing experiments, practical considerations in recording and analysis, and issues in interpreting ERP effects. The present article is necessarily brief and focused, but broader reviews are available

  5. Auditory event-related brain potentials for an early discrimination between normal and pathological brain aging.

    Science.gov (United States)

    Dushanova, Juliana; Christov, Mario

    2013-05-25

    The brain as a system with gradually decreasing resources maximizes its chances by reorganizing neural networks to ensure efficient performance. Auditory event-related potentials were recorded in 28 healthy volunteers comprising 14 young and 14 elderly subjects in auditory discrimination motor task (low frequency tone - right hand movement and high frequency tone - left hand movement). The amplitudes of the sensory event-related potential components (N1, P2) were more pronounced with increasing age for either tone and this effect for P2 amplitude was more pronounced in the frontal region. The latency relationship of N1 between the groups was tone-dependent, while that of P2 was tone-independent with a prominent delay in the elderly group over all brain regions. The amplitudes of the cognitive components (N2, P3) diminished with increasing age and the hemispheric asymmetry of N2 (but not for P3) reduced with increasing age. Prolonged N2 latency with increasing age was widespread for either tone while between-group difference in P3 latency was tone-dependent. High frequency tone stimulation and movement requirements lead to P3 delay in the elderly group. The amplitude difference of the sensory components between the age groups could be due to a general greater alertness, less expressed habituation, or decline in the ability to retreat attentional resources from the stimuli in the elderly group. With aging, a neural circuit reorganization of the brain activity affects the cognitive processes. The approach used in this study is useful for an early discrimination between normal and pathological brain aging for early treatment of cognitive alterations and dementia.

  6. A cognitive stressor for event-related potential studies: the Portland arithmetic stress task.

    Science.gov (United States)

    Atchley, Rachel; Ellingson, Roger; Klee, Daniel; Memmott, Tabatha; Oken, Barry

    2017-05-01

    In this experiment, we developed and evaluated the Portland Arithmetic Stress Task (PAST) as a cognitive stressor to evaluate acute and sustained stress reactivity for event-related potential (ERP) studies. The PAST is a titrated arithmetic task adapted from the Montreal Imaging Stress Task (MIST), with added experimental control over presentation parameters, improved and synchronized acoustic feedback and generation of timing markers needed for physiological analyzes of real-time brain activity. Thirty-one older adults (M = 60 years) completed the PAST. EEG was recorded to assess feedback-related negativity (FRN) and the magnitude of the stress response through autonomic nervous system activity and salivary cortisol. Physiological measures other than EEG included heart rate, respiration rate, heart rate variability, blood pressure and salivary cortisol. These measures were collected at several time points throughout the task. Feedback-related negativity evoked-potential responses were elicited and they significantly differed depending on whether positive or negative feedback was received. The PAST also increased systolic blood pressure, heart rate variability and respiration rates compared to a control condition attentional task. These preliminary results suggest that the PAST is an effective cognitive stressor. Successful measurement of the feedback-related negativity suggests that the PAST is conducive to EEG and time-sensitive ERP experiments. Moreover, the physiological findings support the PAST as a potent method for inducing stress in older adult participants. Further research is needed to confirm these results, but the PAST shows promise as a tool for cognitive stress induction for time-locked event-related potential experiments.

  7. Resilience to traumatic events related to urban violence and increased IL10 serum levels.

    Science.gov (United States)

    Teche, Stefania P; Rovaris, Diego L; Aguiar, Bianca W; Hauck, Simone; Vitola, Eduardo S; Bau, Claiton H D; Freitas, Lucia H; Grevet, Eugenio H

    2017-04-01

    The exposition to traumatic events related to urban violence is epidemic in Brazil, with rate of 80% in the general population, and is becoming a major cause of post-traumatic stress disorder (PTSD). The objective of the study was to compare serum levels of pro-inflammatory interleukin-6 (IL-6) and anti-inflammatory interleukin-10 (IL-10) in PTSD and resilient individuals. We hypothesized that resilient individuals present an attenuated pro-inflammatory and enhanced anti-inflammatory state. We conducted a case-control study comparing 30 resilient individuals and 30 PTSD patients exposed to traumatic events related to urban violence. The groups were evaluated using Self-Report Questionnaire (SRQ-20), Mini-International Neuropsychiatric Interview (MINI) and the Davidson Trauma Scale. For all individuals, blood samples were collected to determine IL-6, IL-10 and cortisol serum levels. All samples were frozen at -80°C until the assay and were analyzed with the same immunoassay kit and in duplicates. The resilient group presented higher IL-10 levels than PTSD patients [mean (CI95%); 1.03 (0.52-2.08) pg/mL vs. 0.29 (0.20-0.43) pg/mL; P=0.002]. There were no differences in terms of IL-6 or cortisol levels. The results provided evidence for increased levels of IL-10 in resilient individuals when compared to PTSD patients, probably conferring them a better anti-inflammatory response after exposition. Copyright © 2017 Elsevier Ireland Ltd. All rights reserved.

  8. Real-time single-shot electron bunch length measurements

    CERN Document Server

    Wilke, I; Gillespie, W A; Berden, G; Knippels, G M H; Meer, A F G

    2002-01-01

    Linear accelerators employed as drivers for X-ray free electron lasers (FELs) require relativistic electron bunch with sub-picosecond bunch length. Precise bunch length measurements are important for the tuning and operation of the FELs. Previously, we have demonstrated that electro-optic detection is a powerful technique for sub-picosecond electron bunch length measurements. In those experiments, the measured bunch length was the average of all electron bunches within a macropulse. Here, for the first time, we present the measurement of the length of individual electron bunches using a development of our previous technique. In this experiment, the longitudinal electron bunch shape is encoded electro-optically on to the frequency spectrum of a chirped laser pulse. Subsequently, the laser pulse is dispersed by a grating and the spectrum is imaged with a CCD camera. Single bunch measurements are achieved by using a nanosecond gated camera, and synchronizing the gate with both the electron bunch and the laser pu...

  9. Quantitative single shot and spatially resolved plasma wakefield diagnostics

    CERN Document Server

    Kasim, Muhammad Firmansyah; Ceurvorst, Luke; Levy, Matthew C; Ratan, Naren; Sadler, James; Bingham, Robert; Burrows, Philip N; Trines, Raoul; Wing, Matthew; Norreys, Peter

    2015-01-01

    Diagnosing plasma conditions can give great advantages in optimizing plasma wakefield accelerator experiments. One possible method is that of photon acceleration. By propagating a laser probe pulse through a plasma wakefield and extracting the imposed frequency modulation, one can obtain an image of the density modulation of the wakefield. In order to diagnose the wakefield parameters at a chosen point in the plasma, the probe pulse crosses the plasma at oblique angles relative to the wakefield. In this paper, mathematical expressions relating the frequency modulation of the laser pulse and the wakefield density profile of the plasma for oblique crossing angles are derived. Multidimensional particle-in-cell simulation results presented in this paper confirm that the frequency modulation profiles and the density modulation profiles agree to within 10%. Limitations to the accuracy of the measurement are discussed in this paper. This technique opens new possibilities to quantitatively diagnose the plasma wakefie...

  10. Single-shot fluctuations in waveguided high-harmonic generation

    NARCIS (Netherlands)

    Goh, S.J.; Tao, Y.; van der Slot, Petrus J.M.; Bastiaens, Hubertus M.J.; Herek, Jennifer Lynn; Biedron, S.G.; Danailov, M.B.; Milton, S.V.; Boller, Klaus J.

    2015-01-01

    For exploring the application potential of coherent soft x-ray (SXR) and extreme ultraviolet radiation (XUV) provided by high-harmonic generation, it is important to characterize the central output parameters. Of specific importance are pulse-to-pulse (shot-to-shot) fluctuations of the high-harmonic

  11. The challenges of single-shot spinal anaesthesia for cesearean ...

    African Journals Online (AJOL)

    An unusual case of morbid obesity, severe hypertension and twin gestation at 36weeks in an unbooked multigravid patient was presented for cesarean section. She was referred from a private clinic to the obstetric emergency unit of the University College Hospital, Ibadan with history of hypertension in pregnancy. She was ...

  12. Interactions between mood and the structure of semantic memory: event-related potentials evidence

    Science.gov (United States)

    Pinheiro, Ana P.; del Re, Elisabetta; Nestor, Paul G; McCarley, Robert W.; Gonçalves, Óscar F.

    2013-01-01

    Recent evidence suggests that affect acts as modulator of cognitive processes and in particular that induced mood has an effect on the way semantic memory is used on-line. We used event-related potentials (ERPs) to examine affective modulation of semantic information processing under three different moods: neutral, positive and negative. Fifteen subjects read 324 pairs of sentences, after mood induction procedure with 30 pictures of neutral, 30 pictures of positive and 30 pictures of neutral valence: 108 sentences were read in each mood induction condition. Sentences ended with three word types: expected words, within-category violations, and between-category violations. N400 amplitude was measured to the three word types under each mood induction condition. Under neutral mood, a congruency (more negative N400 amplitude for unexpected relative to expected endings) and a category effect (more negative N400 amplitude for between- than to within-category violations) were observed. Also, results showed differences in N400 amplitude for both within- and between-category violations as a function of mood: while positive mood tended to facilitate the integration of unexpected but related items, negative mood made their integration as difficult as unexpected and unrelated items. These findings suggest the differential impact of mood on access to long-term semantic memory during sentence comprehension. PMID:22434931

  13. Dopaminergic modulation of performance monitoring in Parkinson's disease: An event-related potential study.

    Science.gov (United States)

    Seer, Caroline; Lange, Florian; Loens, Sebastian; Wegner, Florian; Schrader, Christoph; Dressler, Dirk; Dengler, Reinhard; Kopp, Bruno

    2017-01-24

    Monitoring one's actions is essential for goal-directed performance. In the event-related potential (ERP), errors are followed by fronto-centrally distributed negativities. These error(-related) negativity (N e /ERN) amplitudes are often found to be attenuated in patients with Parkinson's disease (PD) compared to healthy controls (HC). Although N e /ERN has been proposed to be related to dopaminergic neuronal activity, previous research did not find evidence for effects of dopaminergic medication on N e /ERN amplitudes in PD. We examined 13 PD patients "on" and "off" dopaminergic medication. Their response-locked ERP amplitudes (obtained on correct [N c /CRN] and error [N e /ERN] trials of a flanker task) were compared to those of 13 HC who were tested twice as well, without receiving dopaminergic medication. While PD patients committed more errors than HC, error rates were not significantly modulated by dopaminergic medication. PD patients showed reduced N e /ERN amplitudes relative to HC; however, this attenuation of response-locked ERP amplitudes was not specific to errors in this study. PD-related attenuation of response-locked ERP amplitudes was most pronounced when PD patients were on medication. These results suggest overdosing of dopaminergic pathways that are relatively spared in PD, but that are related to the generation of the N e /ERN, notably pathways targeted on the medial prefrontal cortex.

  14. Effects of negative content on the processing of gender information: an event-related potential study.

    Science.gov (United States)

    Hinojosa, José A; Albert, Jacobo; Fernández-Folgueiras, Uxía; Santaniello, Gerardo; López-Bachiller, Cristina; Sebastián, Manuel; Sánchez-Carmona, Alberto J; Pozo, Miguel A

    2014-12-01

    Previous research on emotion in language has mainly concerned the impact of emotional information on several aspects of lexico-semantic analyses of single words. However, affective influences on morphosyntactic processing are less understood. In the present study, we focused on the impact of negative valence in the processing of gender agreement relations. Event-related potentials (ERPs) were recorded while participants read three-word phrases and performed a syntactic judgment task. Negative and neutral adjectives could agree or disagree in gender with the preceding noun. At an electrophysiological level, the amplitude of a left anterior negativity (LAN) to gender agreement mismatches decreased in negative words, relative to neutral words. The behavioral data suggested that LAN amplitudes might be indexing the processing costs associated with the detection of gender agreement errors, since the detection of gender mismatches resulted in faster and more accurate responses than did the detection of correct gender agreement relations. According to this view, it seems that negative content facilitated the processes implicated in the early detection of gender agreement mismatches. However, gender agreement violations in negative words triggered processes involved in the reanalysis and repair of the syntactic structure, as reflected in larger P600 amplitudes to incorrect than to correct phrases, irrespective of their emotional valence.

  15. Multisensory integration and attention in autism spectrum disorder: evidence from event-related potentials.

    Directory of Open Access Journals (Sweden)

    Maurice J C M Magnée

    Full Text Available Successful integration of various simultaneously perceived perceptual signals is crucial for social behavior. Recent findings indicate that this multisensory integration (MSI can be modulated by attention. Theories of Autism Spectrum Disorders (ASDs suggest that MSI is affected in this population while it remains unclear to what extent this is related to impairments in attentional capacity. In the present study Event-related potentials (ERPs following emotionally congruent and incongruent face-voice pairs were measured in 23 high-functioning, adult ASD individuals and 24 age- and IQ-matched controls. MSI was studied while the attention of the participants was manipulated. ERPs were measured at typical auditory and visual processing peaks, namely, P2 and N170. While controls showed MSI during divided attention and easy selective attention tasks, individuals with ASD showed MSI during easy selective attention tasks only. It was concluded that individuals with ASD are able to process multisensory emotional stimuli, but this is differently modulated by attention mechanisms in these participants, especially those associated with divided attention. This atypical interaction between attention and MSI is also relevant to treatment strategies, with training of multisensory attentional control possibly being more beneficial than conventional sensory integration therapy.

  16. Short-Term Effects of Prosocial Video Games on Aggression: An Event-Related Potential Study

    Directory of Open Access Journals (Sweden)

    Yanling eLiu

    2015-07-01

    Full Text Available Previous research has shown that exposure to violent video games increases aggression, whereas exposure to prosocial video games can reduce aggressive behavior. However, little is known about the neural correlates of these behavioral effects. This work is the first to investigate the electrophysiological features of the relationship between playing a prosocial video game and inhibition of aggressive behavior. Forty-nine subjects played either a prosocial or a neutral video game for 20 minutes, then participated in an event-related potential (ERP experiment based on an oddball paradigm and designed to test electrophysiological responses to prosocial and violent words. Finally, subjects completed a competitive reaction time task (CRTT, which is based on Taylor’s Aggression Paradigm and measures both reaction time and noise intensity preference as indices of aggressive behavior. The results show that the prosocial video game group (compared to the neutral video game group displayed smaller P300 amplitudes, were more accurate in distinguishing violent words, and were less aggressive as evaluated by the CRTT (noise intensity preference. A mediation analysis shows that the P300 amplitude evoked by violent words partially mediates the relationship between type of video game and subsequent aggressive behavior. The results support theories based on the General Learning Model. We provide converging behavioral and neural evidence that exposure to prosocial media may reduce aggression.

  17. Event-related potential signatures of perceived and imagined emotional and food real-life photos.

    Science.gov (United States)

    Marmolejo-Ramos, Fernando; Hellemans, Kim; Comeau, Amy; Heenan, Adam; Faulkner, Andrew; Abizaid, Alfonso; D'Angiulli, Amedeo

    2015-06-01

    Although food and affective pictures share similar emotional and motivational characteristics, the relationship between the neuronal responses to these stimuli is unclear. Particularly, it is not known whether perceiving and imagining food and affective stimuli elicit similar event-related potential (ERP) patterns. In this study, two ERP correlates, the early posterior negativity (EPN) and the late positive potential (LPP) for perceived and imagined emotional and food photographs were investigated. Thirteen healthy volunteers were exposed to a set of food photos, as well as unpleasant, pleasant, and neutral photos from the International Affective Picture System. In each trial, participants were first asked to view a photo (perception condition), and then to create a visual mental image of it and to rate its vividness (imagery condition). The results showed that during perception, brain regions corresponding to sensorimotor and parietal motivational (defensive and appetitive) systems were activated to different extents, producing a graded pattern of EPN and LPP responses specific to the photo content - more prominent for unpleasant than pleasant and food content. Also, an EPN signature occurred in both conditions for unpleasant content, suggesting that, compared to food or pleasant content, unpleasant content may be attended to more intensely during perception and may be represented more distinctly during imagery. Finally, compared to LLP activation during perception, as well as imagery and perception of all other content, LPP activation was significantly reduced during imagery of unpleasant photos, suggesting inhibition of unwanted memories. Results are framed within a neurocognitive working model of embodied emotions.

  18. Auditory Event-Related Potentials in the Interictal Phase of Migraine Indicate Alterations in Automatic Attention.

    Science.gov (United States)

    Sable, Jeffrey J; Patrick, Toni A; Woody, Patrick L; Baker, Katelyn R; Allen-Winters, Stephanie; Andrasik, Frank

    2017-12-01

    Migraine has been characterized by interictal cortical hyperresponsivity. We compared event-related brain potentials (ERPs) to unattended tone pairs in migraineurs (interictal) versus non-headache controls, with particular interest in attention-related activity (i.e., the N1 component). Electroencephalograms were recorded from 11 interictal migraineurs and 14 headache-free controls while they watched a silent video. Pairs of 50-ms tones with 500-ms inter-tone intervals were presented with inter-pair intervals of 1 or 5 s. P1, N1, P2, and N2 components were analyzed. N1 peak amplitudes were larger in migraineurs than in controls, especially after the 5-s inter-pair interval. However, there was no difference between groups in the attenuation of the N1 (i.e., no interaction). P2 peak amplitudes were larger in migraineurs, but only after the first tone in the pair. The three migraineurs without aura had larger N1s than the eight with aura. Our findings are consistent with interictal hyperresponsivity of cortical generators of these ERPs in migraineurs. However, areas that inhibit the responses with stimulus repetition do not seem to be affected.

  19. Kernel PLS Estimation of Single-trial Event-related Potentials

    Science.gov (United States)

    Rosipal, Roman; Trejo, Leonard J.

    2004-01-01

    Nonlinear kernel partial least squaes (KPLS) regressior, is a novel smoothing approach to nonparametric regression curve fitting. We have developed a KPLS approach to the estimation of single-trial event related potentials (ERPs). For improved accuracy of estimation, we also developed a local KPLS method for situations in which there exists prior knowledge about the approximate latency of individual ERP components. To assess the utility of the KPLS approach, we compared non-local KPLS and local KPLS smoothing with other nonparametric signal processing and smoothing methods. In particular, we examined wavelet denoising, smoothing splines, and localized smoothing splines. We applied these methods to the estimation of simulated mixtures of human ERPs and ongoing electroencephalogram (EEG) activity using a dipole simulator (BESA). In this scenario we considered ongoing EEG to represent spatially and temporally correlated noise added to the ERPs. This simulation provided a reasonable but simplified model of real-world ERP measurements. For estimation of the simulated single-trial ERPs, local KPLS provided a level of accuracy that was comparable with or better than the other methods. We also applied the local KPLS method to the estimation of human ERPs recorded in an experiment on co,onitive fatigue. For these data, the local KPLS method provided a clear improvement in visualization of single-trial ERPs as well as their averages. The local KPLS method may serve as a new alternative to the estimation of single-trial ERPs and improvement of ERP averages.

  20. Exploring consciousness in emotional face decoding: an event-related potential analysis.

    Science.gov (United States)

    Balconi, Michela

    2006-05-01

    The author analyzed the role of consciousness in emotional face comprehension. The author recorded psychophysiological measures of event-related potentials (ERPs), elicited by supraliminal and subliminal stimuli when participants viewed emotional facial expressions of 4 emotions or neutral stimuli. The author analyzed an ERP emotion-specific effect (N200 peak variation; temporal interval was 180-300 ms poststimulus) in terms of peak amplitude and latency variables. The results indicated 4 important findings. First, there was an emotional-specific ERP deflection only for emotional stimuli, not for neutral stimuli. Second, the unaware information processing was quite similar to that of aware in terms of peak morphology, but not in terms of latency. In fact, unconscious stimulation produced a more delayed peak variation than did conscious stimulation. Third, valence of facial stimulus (positive or negative) was supraliminally and subliminally decoded because it was showed by differences of peak deflection between negative high arousing (fear and anger) and low arousing (happiness, sadness, and neutral) stimuli. Finally, the author found a more posterior distribution of ERP as a function of emotional content of the stimulus. Cortical lateralization (right or left) was not correlated to conscious or unconscious stimulation. The author discussed the functional significance of her results in terms of supraliminal and subliminal conditions.

  1. Event related desynchronization-modulated functional electrical stimulation system for stroke rehabilitation: A feasibility study

    Directory of Open Access Journals (Sweden)

    Takahashi Mitsuru

    2012-08-01

    Full Text Available Abstract Background We developed an electroencephalogram-based brain computer interface system to modulate functional electrical stimulation (FES to the affected tibialis anterior muscle in a stroke patient. The intensity of FES current increased in a stepwise manner when the event-related desynchronization (ERD reflecting motor intent was continuously detected from the primary cortical motor area. Methods We tested the feasibility of the ERD-modulated FES system in comparison with FES without ERD modulation. The stroke patient who presented with severe hemiparesis attempted to perform dorsiflexion of the paralyzed ankle during which FES was applied either with or without ERD modulation. Results After 20 minutes of training, the range of movement at the ankle joint and the electromyography amplitude of the affected tibialis anterior muscle were significantly increased following the ERD-modulated FES compared with the FES alone. Conclusions The proposed rehabilitation technique using ERD-modulated FES for stroke patients was feasible. The system holds potentials to improve the limb function and to benefit stroke patients.

  2. Nicotine enhances an auditory Event-Related Potential component which is inversely related to habituation.

    Science.gov (United States)

    Veltri, Theresa; Taroyan, Naira; Overton, Paul G

    2017-07-01

    Nicotine is a psychoactive substance that is commonly consumed in the context of music. However, the reason why music and nicotine are co-consumed is uncertain. One possibility is that nicotine affects cognitive processes relevant to aspects of music appreciation in a beneficial way. Here we investigated this possibility using Event-Related Potentials. Participants underwent a simple decision-making task (to maintain attentional focus), responses to which were signalled by auditory stimuli. Unlike previous research looking at the effects of nicotine on auditory processing, we used complex tones that varied in pitch, a fundamental element of music. In addition, unlike most other studies, we tested non-smoking subjects to avoid withdrawal-related complications. We found that nicotine (4.0 mg, administered as gum) increased P2 amplitude in the frontal region. Since a decrease in P2 amplitude and latency is related to habituation processes, and an enhanced ability to disengage from irrelevant stimuli, our findings suggest that nicotine may cause a reduction in habituation, resulting in non-smokers being less able to adapt to repeated stimuli. A corollary of that decrease in adaptation may be that nicotine extends the temporal window during which a listener is able and willing to engage with a piece of music.

  3. The arithmetic problem size effect in children: an event-related potential study

    Directory of Open Access Journals (Sweden)

    Leen eVan Beek

    2014-09-01

    Full Text Available This study used for the first time event-related potentials (ERPs to examine the well-known arithmetic problem size effect in children. The electrophysiological correlates of this problem size effect have been well documented in adults, but such information in children is lacking. In the present study, 22 typically developing 12-year-olds were asked to solve single-digit addition problems of small (sum ≤ 10 and large problem size (sum > 10 and to speak the solution into a voice key while ERPs were recorded. Children displayed similar early and late components compared to previous adult studies on the problem size effect. There was no effect of problem size on the early components P1, N1 and P2. The peak amplitude of the N2 component showed more negative potentials on left and right anterior electrodes for large additions compared to small additions, which might reflect differences in attentional and working memory resources between large and small problems. The mean amplitude of the late positivity component (LPC, which follows the N2, was significantly larger for large than for small additions at right parieto-occipital electrodes, in line with previous adult data. The ERPs of the problem size effect during arithmetic might be a useful neural marker for future studies on fact retrieval impairments in children with mathematical difficulties.

  4. Assessing auditory processing disorders in children with developmental dyslexia using auditory cognitive event-related potentials.

    Science.gov (United States)

    Maciejewska, Barbara; Wiskirska-Woźnica, Bożena; Świdziński, Piotr; Michalak, Michał

    2013-01-01

    It has been suggested that dyslexia is linked to a core cognitive deficit in phonological awareness tasks and/or in the processing of auditory stimuli. Auditory evoked potentials are a valid, objective measure of the accuracy of central auditory processing in humans. The aim of this study was to assess auditory evoked potentials in children with dyslexia. Sixty-six children participated in the study. A set of hearing tests and the recording of complex event-related potentials (ERPs) were performed. Mixmatch negativity (MMN) and P300 waves were significantly more frequent in the healthy children (control group) than in children with dyslexia. The P300 wave was present in all subjects from the control group, the MMN wave in 92% of them. In the dyslexic group, complex ERPs were recorded roughly 33% of the time. Latencies of complex ERPs in children with dyslexia were greater than latencies in children in the control group. MMN and P300 maturation (change with age) was observed only for the control group. A wide range of MMN and P300 responses was observed across children with dyslexia. Complex ERPs may be useful in determining the condition of audiologic functions; however, on their own they are not sufficient to recognize dyslexia because of the heterogeneity of nonspecific changes. © 2013 S. Karger AG, Basel.

  5. Location negative priming effects in children with developmental dyslexia: An event-related potential study.

    Science.gov (United States)

    Ma, Yujun; Wang, Enguo; Yuan, Tian; Zhao, Guo Xiang

    2016-08-01

    As the reading process is inseparable from working memory, inhibition, and other higher cognitive processes, the deep cognitive processing defects that are associated with dyslexia may be due to defective distraction inhibition systems. In this study, we used event-related potential technology to explore the source of negative priming effects in children with developmental dyslexia and in a group of healthy children for comparison. We found that the changes in the average response times in the negative priming and control conditions were consistent across the two groups, while the negative priming effects differed significantly between the groups. The magnitude of the negative priming effect was significantly different between the two groups, with the magnitude being significantly higher in the control group than it was in the developmental dyslexia group. These results indicate that there are deficits in distraction inhibition in children with developmental dyslexia. In terms of the time course of processing, inhibition deficits in the dyslexia group appeared during early-stage cognition selection and lasted through the response selection phase. Regarding the cerebral cortex locations, early-stage cognition selection was mainly located in the parietal region, while late-stage response selection was mainly located in the frontal and central regions. The results of our study may help further our understanding of the intrinsic causes of developmental dyslexia. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. [Perceptual conflict and response competition: event-related potentials of the stroop effect].

    Science.gov (United States)

    Bekçi, Belma; Karakaş, Sirel

    2009-01-01

    The aim of the present study was to analyze electrophysiological activity associated with the Stroop effect. The sample included 50 healthy volunteer adults (23 female and 27 male) from the university population. Stimulation, recording and analyses were carried under NeuroScan 4.2 hardware-software system. The effect of the experimental variables (stimulus congruency, response accuracy and electrode location) on event-related potentials (ERPs) was studied using 2x2x3 analysis of variance for repeated measures. The Stroop effect was demonstrated as prolonged reaction time to incongruent stimuli and increased total number of missed stimuli. Principal components analysis (PCA) showed that Stroop performance was related such factors as selective attention, interference, and resistance to interference. The electrophysiological Stroop effect was demonstrated as increased amplitude of P3 and N4 peaks for incongruent stimuli, and of N2, P3, N3, and N4 peaks for incorrect responses. Increased amplitude of P3 and N4 peaks associated with stimulus-related activation has been suggested to reflect conflict detection process. The variations in amplitudes for incorrect responses were complicated. While the amplitude of the N2 and P3 components increased only for incongruent stimuli, those of the N3 and N4 components increased for both congruent and incongruent stimuli. It was concluded that these earlier and later activations were associated with response competition and error detection processes, respectively. In this respect, these findings support both the perceptual conflict and the response competition hypotheses of Stroop interference.

  7. Olfactory short-term memory encoding and maintenance - an event-related potential study.

    Science.gov (United States)

    Lenk, Steffen; Bluschke, Annet; Beste, Christian; Iannilli, Emilia; Rößner, Veit; Hummel, Thomas; Bender, Stephan

    2014-09-01

    This study examined whether the memory encoding and short term maintenance of olfactory stimuli is associated with neurophysiological activation patterns which parallel those described for sensory modalities such as vision and auditory. We examined olfactory event-related potentials in an olfactory change detection task in twenty-four healthy adults and compared the measured activation to that found during passive olfactory stimulation. During the early olfactory post-processing phase, we found a sustained negativity over bilateral frontotemporal areas in the passive perception condition which was enhanced in the active memory task. There was no significant lateralization in either experimental condition. During the maintenance interval at the end of the delay period, we still found sustained activation over bilateral frontotemporal areas which was more negative in trials with correct - as compared to incorrect - behavioural responses. This was complemented by a general significantly stronger frontocentral activation. Summarizing, we were able to show that olfactory short term memory involves a parallel sequence of activation as found in other sensory modalities. In addition to olfactory-specific frontotemporal activations in the memory encoding phase, we found slow cortical potentials over frontocentral areas during the memory maintenance phase indicating the activation of a supramodal memory maintenance system. These findings could represent the neurophysiological underpinning of the 'olfactory flacon', the olfactory counter-part to the visual sketchpad and phonological loop embedded in Baddeley's working memory model. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Event-related potentials during word mapping to object shape predict toddlers’ vocabulary size

    Directory of Open Access Journals (Sweden)

    Kristina eBorgström

    2015-02-01

    Full Text Available What role does attention to different object properties play in early vocabulary development? This longitudinal study using event-related potentials in combination with behavioral measures investigated 20- and 24-month-olds’ (n = 38; n = 34; overlapping n = 24 ability to use object shape and object part information in word-object mapping. The N400 component was used to measure semantic priming by images containing shape or detail information. At 20 months, the N400 to words primed by object shape varied in topography and amplitude depending on vocabulary size, and these differences predicted productive vocabulary size at 24 months. At 24 months, when most of the children had vocabularies of several hundred words, the relation between vocabulary size and the N400 effect in a shape context was weaker. Detached object parts did not function as word primes regardless of age or vocabulary size, although the part-objects were identified behaviorally. The behavioral measure, however, also showed relatively poor recognition of the part-objects compared to the shape-objects. These three findings provide new support for the link between shape recognition and early vocabulary development.

  9. The influence of caffeine on spatial-selective attention: an event-related potential study.

    Science.gov (United States)

    Ruijter, J; de Ruiter, M B; Snel, J; Lorist, M M

    2000-12-01

    Following the indications of previous studies that caffeine might have a specific effect on the processing of spatial information compared with other types of information, the present study investigated the influence of caffeine on an often used spatial-selective attention task. Event-related potentials (ERPs) were recorded from 11 participants under conditions of caffeine (250 mg) and placebo. Spatial-selective attention effects were reflected in the ERPs as more positive going occipital P1 and broadly distributed P2 components, and more negative going occipital-temporal N1 and broadly distributed N2 components. A treatment effect was found as a more positive going frontal P2 component in the caffeine condition, whereas interactions between treatment and attention were observed for P2 and N2 components, but not for P1 and N1 components. This pattern of results suggests that caffeine has no specific influence on spatial-selective attention, but rather, has a more general facilitating effect on perceptual processing, as well as a possible effect on the frontal control mechanisms, i.e. focusing attention and increasing selectivity.

  10. Sensitivity to structure in action sequences: An infant event-related potential study.

    Science.gov (United States)

    Monroy, Claire D; Gerson, Sarah A; Domínguez-Martínez, Estefanía; Kaduk, Katharina; Hunnius, Sabine; Reid, Vincent

    2017-05-06

    Infants are sensitive to structure and patterns within continuous streams of sensory input. This sensitivity relies on statistical learning, the ability to detect predictable regularities in spatial and temporal sequences. Recent evidence has shown that infants can detect statistical regularities in action sequences they observe, but little is known about the neural process that give rise to this ability. In the current experiment, we combined electroencephalography (EEG) with eye-tracking to identify electrophysiological markers that indicate whether 8-11-month-old infants detect violations to learned regularities in action sequences, and to relate these markers to behavioral measures of anticipation during learning. In a learning phase, infants observed an actor performing a sequence featuring two deterministic pairs embedded within an otherwise random sequence. Thus, the first action of each pair was predictive of what would occur next. One of the pairs caused an action-effect, whereas the second did not. In a subsequent test phase, infants observed another sequence that included deviant pairs, violating the previously observed action pairs. Event-related potential (ERP) responses were analyzed and compared between the deviant and the original action pairs. Findings reveal that infants demonstrated a greater Negative central (Nc) ERP response to the deviant actions for the pair that caused the action-effect, which was consistent with their visual anticipations during the learning phase. Findings are discussed in terms of the neural and behavioral processes underlying perception and learning of structured action sequences. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Cognitive processing in non-communicative patients: what can event-related potentials tell us?

    Directory of Open Access Journals (Sweden)

    Zulay Rosario Lugo

    2016-11-01

    Full Text Available Event-related potentials (ERP have been proposed to improve the differential diagnosis of non-responsive patients. We investigated the potential of the P300 as a reliable marker of conscious processing in patients with locked-in syndrome (LIS. Eleven chronic LIS patients and ten healthy subjects (HS listened to a complex-tone auditory oddball paradigm, first in a passive condition (listen to the sounds and then in an active condition (counting the deviant tones. Seven out of nine HS displayed a P300 waveform in the passive condition and all in the active condition. HS showed statistically significant changes in peak and area amplitude between conditions. Three out of seven LIS patients showed the P3 waveform in the passive condition and 5 of 7 in the active condition. No changes in peak amplitude and only a significant difference at one electrode in area amplitude were observed in this group between conditions. We conclude that, in spite of keeping full consciousness and intact or nearly intact cortical functions, compared to HS, LIS patients present less reliable results when testing with ERP, specifically in the passive condition. We thus strongly recommend applying ERP paradigms in an active condition when evaluating consciousness in non-responsive patients.

  12. Distinguishing shyness and sociability in children: An event-related potential study.

    Science.gov (United States)

    Tang, Alva; Santesso, Diane L; Segalowitz, Sidney J; Schmidt, Louis A

    2016-02-01

    Shyness and sociability are independent personality dimensions, each with distinct behavioral and psychophysiological correlates that are conserved across development, culture, and phylogeny. However, relatively little is known regarding how shyness and sociability are instantiated in the brain, particularly during childhood and during the processing of nonsocial stimuli. Using a three-stimulus auditory oddball task, we examined whether variations in shyness and sociability were related to the N200 and P300 event-related potential (ERP) brain responses to processing task-relevant, novel, and standard auditory tones in 53 typically developing 10-year-old children. ERP amplitudes were measured at four midline scalp sites: Fz, FCz, Cz, and Pz. We found that increases in shyness were correlated with increases in target P300 amplitudes across all four head sites, increases in standard P300 amplitudes, and decreases in target P300 latencies in anterior sites. No relations were found for sociability and P300 responses. We also found that P300 amplitude in the frontal region to standard tones mediated the relation between conflicted shyness (i.e., high shyness and high sociability) and emotional instability. These results suggest that shyness and sociability are distinguishable on neurocognitive measures and that these neurocognitive measures may be putative mechanisms in understanding risk for emotional instability and a broad range of dysregulated behavioral problems observed in individuals characterized by conflicted shyness. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Distinguishing shyness and sociability in adults: An event-related electrocortical-neuroendocrine study.

    Science.gov (United States)

    Tang, Alva; Santesso, Diane L; Segalowitz, Sidney J; Schulkin, Jay; Schmidt, Louis A

    2016-09-01

    Shyness and sociability are orthogonal personality dimensions, but little is known about how the two traits are instantiated in the brain and body. Using a 3-stimulus auditory oddball task, we examined whether shyness and sociability were distinguishable on P300 event-related potentials (ERPs) in processing task-relevant, novel, and standard auditory tones in 48 young adults. ERP amplitudes were measured at four midline scalp sites (Fz, FCz, Cz, Pz). We found that shyness, but not sociability, was related to reduced frontal novelty P300 amplitudes and to high emotionality. We also found that low baseline salivary cortisol levels mediated the relation between: (a) high shyness and reduced frontal P300 amplitudes to novel tones, and (b) high shyness and high scores of emotionality. We speculate that low baseline cortisol may serve as a putative mechanism influencing central attentional states of avoidance to threat and novelty and emotional arousal in adults who are shy. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Time-Frequency Data Reduction for Event Related Potentials: Combining Principal Component Analysis and Matching Pursuit.

    Science.gov (United States)

    Aviyente, Selin; Bernat, Edward M; Malone, Stephen M; Iacono, William G

    2010-01-01

    Joint time-frequency representations offer a rich representation of event related potentials (ERPs) that cannot be obtained through individual time or frequency domain analysis. This representation, however, comes at the expense of increased data volume and the difficulty of interpreting the resulting representations. Therefore, methods that can reduce the large amount of time-frequency data to experimentally relevant components are essential. In this paper, we present a method that reduces the large volume of ERP time-frequency data into a few significant time-frequency parameters. The proposed method is based on applying the widely-used matching pursuit (MP) approach, with a Gabor dictionary, to principal components extracted from the time-frequency domain. The proposed PCA-Gabor decomposition is compared with other time-frequency data reduction methods such as the time-frequency PCA approach alone and standard matching pursuit methods using a Gabor dictionary for both simulated and biological data. The results show that the proposed PCA-Gabor approach performs better than either the PCA alone or the standard MP data reduction methods, by using the smallest amount of ERP data variance to produce the strongest statistical separation between experimental conditions.

  15. Morphological encoding in German children's language production: evidence from event-related brain potentials.

    Science.gov (United States)

    Jessen, Anna; Fleischhauer, Elisabeth; Clahsen, Harald

    2017-03-01

    This study reports developmental changes in morphological encoding across late childhood. We examined event-related brain potentials (ERPs) during the silent production of regularly vs. irregularly inflected verb forms (viz. -t vs. -n participles of German) in groups of eight- to ten-year-olds, eleven- to thirteen-year-olds, and adults. The adult data revealed an enhanced (right-frontal) negativity 300-450 ms after cue onset for the (silent) production of -t relative to -n past participle forms (e.g. geplant vs. gehauen 'planned' vs. 'hit'). For the eleven- to thirteen-year-olds, the same enhanced negativity was found, with a more posterior distribution and a longer duration (=300-550 ms). The eight- to ten-year-olds also showed this negativity, again with a posterior distribution, but with a considerably delayed onset (800-1,000 ms). We suggest that this negativity reflects combinatorial processing required for producing -t participles in both children and adults and that the spatial and temporal modulations of this ERP effect across the three participant groups are due to developmental changes of the brain networks involved in processing morphologically complex words.

  16. Brain Signals of Face Processing as Revealed by Event-Related Potentials.

    Science.gov (United States)

    Olivares, Ela I; Iglesias, Jaime; Saavedra, Cristina; Trujillo-Barreto, Nelson J; Valdés-Sosa, Mitchell

    2015-01-01

    We analyze the functional significance of different event-related potentials (ERPs) as electrophysiological indices of face perception and face recognition, according to cognitive and neurofunctional models of face processing. Initially, the processing of faces seems to be supported by early extrastriate occipital cortices and revealed by modulations of the occipital P1. This early response is thought to reflect the detection of certain primary structural aspects indicating the presence grosso modo of a face within the visual field. The posterior-temporal N170 is more sensitive to the detection of faces as complex-structured stimuli and, therefore, to the presence of its distinctive organizational characteristics prior to within-category identification. In turn, the relatively late and probably more rostrally generated N250r and N400-like responses might respectively indicate processes of access and retrieval of face-related information, which is stored in long-term memory (LTM). New methods of analysis of electrophysiological and neuroanatomical data, namely, dynamic causal modeling, single-trial and time-frequency analyses, are highly recommended to advance in the knowledge of those brain mechanisms concerning face processing.

  17. Response inhibition in borderline personality disorder: event-related potentials in a Go/Nogo task.

    Science.gov (United States)

    Ruchsow, M; Groen, G; Kiefer, M; Buchheim, A; Walter, H; Martius, P; Reiter, M; Hermle, L; Spitzer, M; Ebert, D; Falkenstein, M

    2008-01-01

    Borderline personality disorder (BPD) has been related to a dysfunction of anterior cingulate cortex, amygdala, and prefrontal cortex and has been associated clinically with impulsivity, affective instability, and significant interpersonal distress. We examined 17 patients with BPD and 17 age-, sex-, and education matched control participants with no history of Axis I or II psychopathology using event-related potentials (ERPs). Participants performed a hybrid flanker-Go/Nogo task while multichannel EEG was recorded. Our study focused on two ERP components: the Nogo-N2 and the Nogo-P3, which have been discussed in the context of response inhibition and response conflict. ERPs were computed on correct Go trials (button press) and correct Nogo trials (no button press), separately. Groups did not differ with regard to the Nogo-N2. However, BPD patients showed reduced Nogo-P3 amplitudes. For the entire group (n = 34) we found a negative correlation with the Barratt Impulsiveness Scale (BIS-10) and Becks's depression inventory (BDI). The present study is the first to examine Nogo-N2 and Nogo-P3 in BPD and provides further evidence for impaired response inhibition in BPD patients.

  18. [Event-related EEG potentials associated with error detection in psychiatric disorder: literature review].

    Science.gov (United States)

    Balogh, Lívia; Czobor, Pál

    2010-01-01

    Error-related bioelectric signals constitute a special subgroup of event-related potentials. Researchers have identified two evoked potential components to be closely related to error processing, namely error-related negativity (ERN) and error-positivity (Pe), and they linked these to specific cognitive functions. In our article first we give a brief description of these components, then based on the available literature, we review differences in error-related evoked potentials observed in patients across psychiatric disorders. The PubMed and Medline search engines were used in order to identify all relevant articles, published between 2000 and 2009. For the purpose of the current paper we reviewed publications summarizing results of clinical trials. Patients suffering from schizophrenia, anorexia nervosa or borderline personality disorder exhibited a decrease in the amplitude of error-negativity when compared with healthy controls, while in cases of depression and anxiety an increase in the amplitude has been observed. Some of the articles suggest specific personality variables, such as impulsivity, perfectionism, negative emotions or sensitivity to punishment to underlie these electrophysiological differences. Research in the field of error-related electric activity has come to the focus of psychiatry research only recently, thus the amount of available data is significantly limited. However, since this is a relatively new field of research, the results available at present are noteworthy and promising for future electrophysiological investigations in psychiatric disorders.

  19. Event-related potential correlates of suspicious thoughts in individuals with schizotypal personality features.

    Science.gov (United States)

    Li, Xue-bing; Huang, Jia; Cheung, Eric F C; Gong, Qi-yong; Chan, Raymond C K

    2011-01-01

    Suspiciousness is a common feature of schizophrenia. However, suspicious thoughts are also commonly experienced by the general population. This study aimed to examine the underlying neural mechanism of suspicious thoughts in individuals with and without schizotypal personality disorder (SPD)-proneness, using an event-related potential (ERP) paradigm. Electroencephalography (EEG) was recorded when the "feeling of being seen through" was evoked in the participants. The findings showed a prominent positive deflection of the difference wave within the time window 250-400 ms after stimuli presentation in both SPD-prone and non-SPD-prone groups. Furthermore, the P3 amplitude was significantly reduced in the SPD-prone group compared to the non-SPD-prone group. The current density analysis also indicated hypoactivity in both frontal and temporal regions in the SPD-prone group, suggesting that the frontotemporal cortical network may play a role in the onset of suspicious thoughts. The P3 of difference wave was inversely correlated with the cognitive-perception factor and the suspiciousness/paranoid ideation trait, which provided preliminary electrophysiological evidence for the association of suspiciousness with SPD features.

  20. Event-related potential evidence of accessing gender stereotypes to aid source monitoring.

    Science.gov (United States)

    Leynes, P Andrew; Crawford, Jarret T; Radebaugh, Anne M; Taranto, Elizabeth

    2013-01-23

    Source memory for the speaker's voice (male or female) was investigated when semantic knowledge (gender stereotypes) could and could not inform the episodic source judgment while event-related potentials (ERPs) were recorded. Source accuracy was greater and response times were faster when stereotypes could predict the speaker's voice at test. Recollection supported source judgments in both conditions as indicated by significant parietal "old/new" ERP effects (500-800ms). Prototypical late ERP effects (the right frontal "old/new" effect and the late posterior negativity, LPN) were evident when source judgment was based solely on episodic memory. However, these two late ERP effects were diminished and a novel, frontal-negative ERP with left-central topography was observed when stereotypes aided source judgments. This pattern of ERP activity likely reflects activation of left frontal or left temporal lobes when semantic knowledge, in the form of a gender stereotype, is accessed to inform the episodic source judgment. Copyright © 2012 Elsevier B.V. All rights reserved.

  1. Neurophysiological traces of interpersonal pain: How emotional autobiographical memories affect event-related potentials.

    Science.gov (United States)

    Rohde, Kristina B; Caspar, Franz; Koenig, Thomas; Pascual-Leone, Antonio; Stein, Maria

    2018-03-01

    The automatic, involuntary reactivation of disturbing emotional memories, for example, of interpersonal pain, causes psychological discomfort and is central to many psychopathologies. This study aimed at elucidating the automatic brain processes underlying emotional autobiographical memories by investigating the neurophysiological dynamics within the first second after memory reactivation. Pictures of different individualized familiar faces served as cues for different specific emotional autobiographical memories, for example, for memories of interpersonal pain and grievances or for memories of appreciation in interpersonal relationships. Nineteen subjects participated in a passive face-viewing task while multichannel electroencephalogram was recorded. Analyses of event-related potentials demonstrated that emotional memories elicited an early posterior negativity and a stronger late positive potential, which tended to be particularly enhanced for painful memories. Source estimations attributed this stronger activation to networks including the posterior cingulate and ventrolateral prefrontal cortices. The findings suggest that the reactivation of emotional autobiographical memories involves privileged automatic attention at perceptual processing stages, and an enhanced recruitment of neural network activity at a postperceptual stage sensitive to emotional-motivational processing. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  2. Modafinil improves event related potentials P300 and contingent negative variation after 24 h sleep deprivation.

    Science.gov (United States)

    Ray, Koushik; Chatterjee, Abhirup; Panjwani, Usha; Kumar, Sanjeev; Sahu, Surajit; Ghosh, Sayan; Thakur, Lalan; Anand, Jag Parvesh

    2012-08-21

    The efficacy of modafinil as a countermeasure in the reduction of cognitive decline following 24 h of sleep deprivation (SD) on subjective sleepiness scales, event-related potential (ERP) P300, and contingent negative variation (CNV) was evaluated. Eleven healthy males, age 25-30 years participated. The experiment was performed in five sessions on different days between 7 and 8a.m. Session 1, baseline recordings; Session 2, after one night's SD; Session 3, 48 h of recovery from SD; Session 4, after 1 week of Session 1, following one night's SD along with modafinil (400mg/day); Session 5, 48 h of recovery after SD+modafinil. Subjective sleepiness scores increased significantly after SD as compared to baseline (Pmodafinil supplementation. There was an increase in N100 and P300 peak latencies of ERP following SD (Pmodafinil (Pmodafinil (Pmodafinil (Pmodafinil in a dose of 400mg/day, reduces the subjective sleepiness and cognitive decline following 24 h of SD. Copyright © 2012 Elsevier Inc. All rights reserved.

  3. Subclinical alexithymia modulates early audio-visual perceptive and attentional event-related potentials.

    Science.gov (United States)

    Delle-Vigne, Dyna; Kornreich, Charles; Verbanck, Paul; Campanella, Salvatore

    2014-01-01

    Previous studies have highlighted the advantage of using audio-visual oddball tasks (instead of unimodal ones) in order to electrophysiologically index subclinical behavioral differences. Since alexithymia is highly prevalent in the general population, we investigated whether the use of various bimodal tasks could elicit emotional effects in low- vs. high-alexithymic scorers. Fifty students (33 females and 17 males) were split into groups based on low and high scores on the Toronto Alexithymia Scale (TAS-20). During event-related potential (ERP) recordings, they were exposed to three kinds of audio-visual oddball tasks: neutral-AVN-(geometrical forms and bips), animal-AVA-(dog and cock with their respective shouts), or emotional-AVE-(faces and voices) stimuli. In each condition, participants were asked to quickly detect deviant events occurring amongst a train of repeated and frequent matching stimuli (e.g., push a button when a sad face-voice pair appeared amongst a train of neutral face-voice pairs). P100, N100, and P300 components were analyzed: P100 refers to visual perceptive and attentional processing, N100 to auditory ones, and the P300 relates to response-related stages, involving memory processes. High-alexithymic scorers presented a particular pattern of results when processing the emotional stimulations, reflected in early ERP components by increased P100 and N100 amplitudes in the emotional oddball tasks [P100: F (2, 48) = 20,319, p stimuli.

  4. Short-term effects of prosocial video games on aggression: an event-related potential study

    Science.gov (United States)

    Liu, Yanling; Teng, Zhaojun; Lan, Haiying; Zhang, Xin; Yao, Dezhong

    2015-01-01

    Previous research has shown that exposure to violent video games increases aggression, whereas exposure to prosocial video games can reduce aggressive behavior. However, little is known about the neural correlates of these behavioral effects. This work is the first to investigate the electrophysiological features of the relationship between playing a prosocial video game and inhibition of aggressive behavior. Forty-nine subjects played either a prosocial or a neutral video game for 20 min, then participated in an event-related potential (ERP) experiment based on an oddball paradigm and designed to test electrophysiological responses to prosocial and violent words. Finally, subjects completed a competitive reaction time task (CRTT) which based on Taylor's Aggression Paradigm and contains reaction time and noise intensity chosen as a measure of aggressive behavior. The results show that the prosocial video game group (compared to the neutral video game group) displayed smaller P300 amplitudes, were more accurate in distinguishing violent words, and were less aggressive as evaluated by the CRTT of noise intensity chosen. A mediation analysis shows that the P300 amplitude evoked by violent words partially mediates the relationship between type of video game and subsequent aggressive behavior. The results support theories based on the General Learning Model. We provide converging behavioral and neural evidence that exposure to prosocial media may reduce aggression. PMID:26257620

  5. Impaired Empathy Processing in Individuals with Internet Addiction Disorder: An Event-Related Potential Study

    Directory of Open Access Journals (Sweden)

    Can Jiao

    2017-10-01

    Full Text Available Internet addiction disorder (IAD is associated with deficits in social communication and avoidance of social contact. It has been hypothesized that people with IAD may have an impaired capacity for empathy. The purpose of the current study was to examine the processing of empathy for others’ pain in IADs. Event-related potentials produced in response to pictures showing others in painful and non-painful situations were recorded in 16 IAD subjects and 16 healthy controls (HCs. The N1, P2, N2, P3, and late positive potential components were compared between the two groups. Robust picture × group interactions were observed for N2 and P3. The painful pictures elicited larger N2 and P3 amplitudes than the non-painful pictures did only in the HC group but not in the IAD group. The results of this study suggest that both of the early automatic and of the later cognitive processes of pain empathy may be impaired in IADs. This study provides psychophysical evidence of empathy deficits in association with IAD. Further studies combining multidimensional measurements of empathy are needed to confirm these findings.

  6. Specific neural basis of Chinese idioms processing: an event-related functional MRI study

    International Nuclear Information System (INIS)

    Chen Shaoqi; Zhang Yanzhen; Xiao Zhuangwei; Zhang Xuexin

    2007-01-01

    Objective: To address the neural basis of Chinese idioms processing with different kinds of stimuli using an event-related fMRI design. Methods: Sixteen native Chinese speakers were asked to perform a semantic decision task during fMRI scanning. Three kinds of stimuli were used: Real idioms (Real-idiom condition); Literally plausible phrases (Pseudo-idiom condition, the last character of a real idiom was replaced by a character with similar meaning); Literally implausible strings (Non-idiom condition, the last character of a real idiom was replaced by a character with unrelated meaning). Reaction time and correct rate were recorded at the same time. Results: The error rate was 2.6%, 5.2% and 0.9% (F=3.51, P 0.05) for real idioms, pseudo-idioms and wrong idioms, respectively. Similar neural network was activated in all of the three conditions. However, the right hippocampus was only activated in the real idiom condition, and significant activations were found in anterior portion of left inferior frontal gyms (BA47) in real-and pseudo-idiom conditions, but not in non-idiom condition. Conclusion: The right hippocampus plays a specific role in the particular wording of the Chinese idioms. And the left anterior inferior frontal gyms (BA47) may be engaged in the semantic processing of Chinese idioms. The results support the notion that there were specific neural bases for Chinese idioms processing. (authors)

  7. Trial latencies estimation of event-related potentials in EEG by means of genetic algorithms

    Science.gov (United States)

    Da Pelo, P.; De Tommaso, M.; Monaco, A.; Stramaglia, S.; Bellotti, R.; Tangaro, S.

    2018-04-01

    Objective. Event-related potentials (ERPs) are usually obtained by averaging thus neglecting the trial-to-trial latency variability in cognitive electroencephalography (EEG) responses. As a consequence the shape and the peak amplitude of the averaged ERP are smeared and reduced, respectively, when the single-trial latencies show a relevant variability. To date, the majority of the methodologies for single-trial latencies inference are iterative schemes providing suboptimal solutions, the most commonly used being the Woody’s algorithm. Approach. In this study, a global approach is developed by introducing a fitness function whose global maximum corresponds to the set of latencies which renders the trial signals most aligned as possible. A suitable genetic algorithm has been implemented to solve the optimization problem, characterized by new genetic operators tailored to the present problem. Main results. The results, on simulated trials, showed that the proposed algorithm performs better than Woody’s algorithm in all conditions, at the cost of an increased computational complexity (justified by the improved quality of the solution). Application of the proposed approach on real data trials, resulted in an increased correlation between latencies and reaction times w.r.t. the output from RIDE method. Significance. The above mentioned results on simulated and real data indicate that the proposed method, providing a better estimate of single-trial latencies, will open the way to more accurate study of neural responses as well as to the issue of relating the variability of latencies to the proper cognitive and behavioural correlates.

  8. Auditory event-related potentials associated with perceptual reversals of bistable pitch motion.

    Science.gov (United States)

    Davidson, Gray D; Pitts, Michael A

    2014-01-01

    Previous event-related potential (ERP) experiments have consistently identified two components associated with perceptual transitions of bistable visual stimuli, the "reversal negativity" (RN) and the "late positive complex" (LPC). The RN (~200 ms post-stimulus, bilateral occipital-parietal distribution) is thought to reflect transitions between neural representations that form the moment-to-moment contents of conscious perception, while the LPC (~400 ms, central-parietal) is considered an index of post-perceptual processing related to accessing and reporting one's percept. To explore the generality of these components across sensory modalities, the present experiment utilized a novel bistable auditory stimulus. Pairs of complex tones with ambiguous pitch relationships were presented sequentially while subjects reported whether they perceived the tone pairs as ascending or descending in pitch. ERPs elicited by the tones were compared according to whether perceived pitch motion changed direction or remained the same across successive trials. An auditory reversal negativity (aRN) component was evident at ~170 ms post-stimulus over bilateral fronto-central scalp locations. An auditory LPC component (aLPC) was evident at subsequent latencies (~350 ms, fronto-central distribution). These two components may be auditory analogs of the visual RN and LPC, suggesting functionally equivalent but anatomically distinct processes in auditory vs. visual bistable perception.

  9. Grouping of sequential sounds--an event-related potential study comparing musicians and nonmusicians.

    Science.gov (United States)

    van Zuijen, Titia L; Sussman, Elyse; Winkler, István; Näätänen, Risto; Tervaniemi, Mari

    2004-03-01

    It is believed that auditory processes governing grouping and segmentation of sounds are automatic and represent universal aspects of music perception (e.g., they are independent of the listener's musical skill). The present study challenges this view by showing that musicians and nonmusicians differ in their ability to preattentively group consecutive sounds. We measured event-related potentials (ERPs) from professional musicians and nonmusicians who were presented with isochronous tone sequences that they ignored. Four consecutive tones in a sequence could be grouped according to either pitch similarity or good continuation of pitch. Occasionally, the tone-group length was violated by a deviant tone. The mismatch negativity (MMN) was elicited to the deviants in both subject groups when the sounds could be grouped based on pitch similarity. In contrast, MMN was only elicited in musicians when the sounds could be grouped according to good continuation of pitch. These results suggest that some forms of auditory grouping depend on musical skill and that not all aspects of auditory grouping are universal.

  10. From sensation to percept: the neural signature of auditory event-related potentials.

    Science.gov (United States)

    Joos, Kathleen; Gilles, Annick; Van de Heyning, Paul; De Ridder, Dirk; Vanneste, Sven

    2014-05-01

    An external auditory stimulus induces an auditory sensation which may lead to a conscious auditory perception. Although the sensory aspect is well known, it is still a question how an auditory stimulus results in an individual's conscious percept. To unravel the uncertainties concerning the neural correlates of a conscious auditory percept, event-related potentials may serve as a useful tool. In the current review we mainly wanted to shed light on the perceptual aspects of auditory processing and therefore we mainly focused on the auditory late-latency responses. Moreover, there is increasing evidence that perception is an active process in which the brain searches for the information it expects to be present, suggesting that auditory perception requires the presence of both bottom-up, i.e. sensory and top-down, i.e. prediction-driven processing. Therefore, the auditory evoked potentials will be interpreted in the context of the Bayesian brain model, in which the brain predicts which information it expects and when this will happen. The internal representation of the auditory environment will be verified by sensation samples of the environment (P50, N100). When this incoming information violates the expectation, it will induce the emission of a prediction error signal (Mismatch Negativity), activating higher-order neural networks and inducing the update of prior internal representations of the environment (P300). Copyright © 2014 Elsevier Ltd. All rights reserved.

  11. Single-Trial Event-Related Potential Based Rapid Image Triage System

    Directory of Open Access Journals (Sweden)

    Ke Yu

    2011-06-01

    Full Text Available Searching for points of interest (POI in large-volume imagery is a challenging problem with few good solutions. In this work, a neural engineering approach called rapid image triage (RIT which could offer about a ten-fold speed up in POI searching is developed. It is essentially a cortically-coupled computer vision technique, whereby the user is presented bursts of images at a speed of 6–15 images per second and then neural signals called event-related potential (ERP is used as the ‘cue’ for user seeing images of high relevance likelihood. Compared to past efforts, the implemented system has several unique features: (1 it applies overlapping frames in image chip preparation, to ensure rapid image triage performance; (2 a novel common spatial-temporal pattern (CSTP algorithm that makes use of both spatial and temporal patterns of ERP topography is proposed for high-accuracy single-trial ERP detection; (3 a weighted version of probabilistic support-vector-machine (SVM is used to address the inherent unbalanced nature of single-trial ERP detection for RIT. High accuracy, fast learning, and real-time capability of the developed system shown on 20 subjects demonstrate the feasibility of a brainmachine integrated rapid image triage system for fast detection of POI from large-volume imagery.

  12. Event-related potentials for 7-month-olds' processing of animals and furniture items.

    Science.gov (United States)

    Elsner, Birgit; Jeschonek, Susanna; Pauen, Sabina

    2013-01-01

    Event-related potentials (ERPs) to single visual stimuli were recorded in 7-month-old infants. In a three-stimulus oddball paradigm, infants watched one frequently occurring standard stimulus (either an animal or a furniture item) and two infrequently occurring oddball stimuli, presenting one exemplar from the same and one from the different superordinate category as compared to the standard stimulus. Additionally, visual attributes of the stimuli were controlled to investigate whether infants focus on category membership or on perceptual similarity when processing the stimuli. Infant ERPs indicated encoding of the standard stimulus and discriminating it from the two oddball stimuli by larger Nc peak amplitude and late-slow-wave activity for the infrequent stimuli. Moreover, larger Nc latency and positive-slow-wave activity indicated increased processing for the different-category as compared to the same-category oddball. Thus, 7-month-olds seem to encode single stimuli not only by surface perceptual features, but they also regard information of category membership, leading to facilitated processing of the oddball that belongs to the same domain as the standard stimulus. Copyright © 2012 Elsevier Ltd. All rights reserved.

  13. An event-related potential study of semantic style-match judgments of artistic furniture.

    Science.gov (United States)

    Lin, Ming-Huang; Wang, Ching-yi; Cheng, Shih-kuen; Cheng, Shih-hung

    2011-11-01

    This study investigates how semantic networks represent different artistic furniture. Event-related potentials (ERPs) were recorded while participants made style-match judgments for table and chair sets. All of the tables were in the Normal style, whereas the chairs were in the Normal, Minimal, ReadyMade, or Deconstruction styles. The Normal and Minimal chairs had the same rates of "match" responses, which were both higher than the rates for the ReadyMade and Deconstruction chairs. Compared with Normal chairs, the ERPs elicited by both ReadyMade chairs and Deconstruction chairs exhibited reliable N400 effects, which suggests that these two design styles were unlike the Normal design style. However, Minimal chairs evoked ERPs that were similar to the ERPs of Normal chairs. Furthermore, the N400 effects elicited by ReadyMade and Deconstruction chairs showed different scalp distributions. These findings reveal that semantic networks represent different design styles for items of the same category. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Relationship between early and late stages of information processing: an event-related potential study

    Directory of Open Access Journals (Sweden)

    Claudio Portella

    2012-11-01

    Full Text Available The brain is capable of elaborating and executing different stages of information processing. However, exactly how these stages are processed in the brain remains largely unknown. This study aimed to analyze the possible correlation between early and late stages of information processing by assessing the latency to, and amplitude of, early and late event-related potential (ERP components, including P200, N200, premotor potential (PMP and P300, in healthy participants in the context of a visual oddball paradigm. We found a moderate positive correlation among the latency of P200 (electrode O2, N200 (electrode O2, PMP (electrode C3, P300 (electrode PZ and the reaction time (RT. In addition, moderate negative correlation between the amplitude of P200 and the latencies of N200 (electrode O2, PMP (electrode C3, P300 (electrode PZ was found. Therefore, we propose that if the secondary processing of visual input (P200 latency occurs faster, the following will also happen sooner: discrimination and classification process of this input (N200 latency, motor response processing (PMP latency, reorganization of attention and working memory update (P300 latency, and RT. N200, PMP, and P300 latencies are also anticipated when higher activation level of occipital areas involved in the secondary processing of visual input rise (P200 amplitude.

  15. Causality in the association between P300 and alpha event-related desynchronization.

    Directory of Open Access Journals (Sweden)

    Weiwei Peng

    Full Text Available Recent findings indicated that both P300 and alpha event-related desynchronization (α-ERD were associated, and similarly involved in cognitive brain functioning, e.g., attention allocation and memory updating. However, an explicit causal influence between the neural generators of P300 and α-ERD has not yet been investigated. In the present study, using an oddball task paradigm, we assessed the task effect (target vs. non-target on P300 and α-ERD elicited by stimuli of four sensory modalities, i.e., audition, vision, somatosensory, and pain, estimated their respective neural generators, and investigated the information flow among their neural generators using time-varying effective connectivity in the target condition. Across sensory modalities, the scalp topographies of P300 and α-ERD were similar and respectively maximal at parietal and occipital regions in the target condition. Source analysis revealed that P300 and α-ERD were mainly generated from posterior cingulate cortex and occipital lobe respectively. As revealed by time-varying effective connectivity, the cortical information was consistently flowed from α-ERD sources to P300 sources in the target condition for all four sensory modalities. All these findings showed that P300 in the target condition is modulated by the changes of α-ERD, which would be useful to explore neural mechanism of cognitive information processing in the human brain.

  16. Rejection in Bargaining Situations: An Event-Related Potential Study in Adolescents and Adults.

    Directory of Open Access Journals (Sweden)

    Kiki Zanolie

    Full Text Available The neural correlates of rejection in bargaining situations when proposing a fair or unfair offer are not yet well understood. We measured neural responses to rejection and acceptance of monetary offers with event-related potentials (ERPs in mid-adolescents (14-17 years and early adults (19-24 years. Participants played multiple rounds of the Ultimatum Game as proposers, dividing coins between themselves and a second player (responder by making a choice between an unfair distribution (7 coins for proposer and 3 for responder; 7/3 and one of two alternatives: a fair distribution (5/5 or a hyperfair distribution (3/7. Participants mostly made fair offers (5/5 when the alternative was unfair (7/3, but made mostly unfair offers (7/3 when the alternative was hyperfair (3/7. When participants' fair offers (5/5; alternative was 7/3 were rejected this was associated with a larger Medial Frontal Negativity (MFN compared to acceptance of fair offers and rejection of unfair offers (7/3; alternative was 3/7. Also, the MFN was smaller after acceptance of unfair offers (7/3 compared to rejection. These neural responses did not differ between adults and mid-adolescents, suggesting that the MFN reacts as a neural alarm system to social prediction errors which is already prevalent during adolescence.

  17. Single-trial event-related potential extraction through one-unit ICA-with-reference

    Science.gov (United States)

    Lih Lee, Wee; Tan, Tele; Falkmer, Torbjörn; Leung, Yee Hong

    2016-12-01

    Objective. In recent years, ICA has been one of the more popular methods for extracting event-related potential (ERP) at the single-trial level. It is a blind source separation technique that allows the extraction of an ERP without making strong assumptions on the temporal and spatial characteristics of an ERP. However, the problem with traditional ICA is that the extraction is not direct and is time-consuming due to the need for source selection processing. In this paper, the application of an one-unit ICA-with-Reference (ICA-R), a constrained ICA method, is proposed. Approach. In cases where the time-region of the desired ERP is known a priori, this time information is utilized to generate a reference signal, which is then used for guiding the one-unit ICA-R to extract the source signal of the desired ERP directly. Main results. Our results showed that, as compared to traditional ICA, ICA-R is a more effective method for analysing ERP because it avoids manual source selection and it requires less computation thus resulting in faster ERP extraction. Significance. In addition to that, since the method is automated, it reduces the risks of any subjective bias in the ERP analysis. It is also a potential tool for extracting the ERP in online application.

  18. Event-related potentials show taste and risk effects on food evaluation.

    Science.gov (United States)

    Ma, Qingguo; Wang, Cuicui; Wu, Yifan; Wang, Xiaoyi

    2014-07-09

    Tastes and claims about unhealthy food are important factors that affect consumption. This study investigated the correlation of the event-related potential (ERP) of the evaluation of processing of food information with the task of positive judgment. Given the information on possible diseases that arise with food consumption, sweet-tasting food elicited more conflict than salty food, and this conflict was reflected by a negative ERP component at 250-500 ms (N400). Moreover, the late positive wave at 500-800 ms that was evoked by presentation of food with the names of chronic diseases that could arise from the consumption of such food was larger than that evoked when acute diseases were presented. Sweet-tasting food caused a more intense conflict with disease-related risk than salty food, and chronic diseases aroused a stronger emotional fear than acute diseases. These findings provide new insights into the N400 component and the neurocognitive processes of evaluating food combined with taste and risk information.

  19. Event-related potential correlates of serial-position effects during an elaborative memory test.

    Science.gov (United States)

    Rushby, Jacqueline A; Barry, Robert J; Johnstone, Stuart S

    2002-10-01

    Twenty undergraduate students participated in an elaborative learning test to evaluate the relationship between electrical brain activity and subsequently recalled and not-recalled words. Data collected from the midline (Fz, Cz, Pz) and lateral scalp sites (F3, F4, C3, C4, P3, P4) were analysed. The difference between event-related potentials (ERPs) elicited by subsequently recalled and not-recalled words, the ERP memory effect, was evaluated for each portion (primacy, plateau and recency) of the serial-position curve (SPC). We compared peak amplitudes for the P1, N1, P2, N400, P3 and frontal positive slow wave (FPSW) components. The electrophysiological data support the hypothesis that different mechanisms underlie primacy and recency effects during free recall paradigms. There was no support for the hypothesis that an association arises between memory and the FPSW when subjects utilise elaborative learning strategies. The P2 component predicted subsequent recall at the primacy portion of the SPC, and P1 predicted recall at the primacy and plateau portions of the curve. The findings suggest that the early positive components of the ERP (i.e. P1 and P2) are useful indices of the differential stimulus processing during elaborative learning which predicts later recall. Copyright 2002 Elsevier Science B.V.

  20. Evidence for Attentional Gradient in the Serial Position Memory Curve from Event-related Potentials

    Science.gov (United States)

    Azizian, Allen; Polich, John

    2009-01-01

    The occurrence of primacy versus recency effects in free recall is suggested to reflect either two distinct memory systems, or the operation of a single system that is modulated by allocation of attention and less vulnerable to interference. Behavioral and event-related brain potential (ERPs) measures were used to investigate the encoding substrates of the serial position curve and subsequent recall in young adults. Participants were instructed to remember lists of words consisting of 12 common nouns each presented once every 1.5 sec, with a recall signal following the last word to indicate that all remembered items should be written on paper. This procedure was repeated for 20 different word lists. Both performance and late ERP amplitudes reflected classic recall serial position effects. Greater recall and larger late positive component amplitudes were obtained for the primacy and recency items, with less recall and smaller amplitudes for the middle words. The late positive component was larger for recalled compared to unrecalled primacy items, but it did not differ between memory performance outcomes for the recency items. The close relationship between the enhanced amplitude and primacy retrieval supports the view that this positive component reflects one of a process series related to attentional gradient and encoding of events for storage in memory. Recency effects appear to index operations determined by the anticipation of the last stimulus presentation, which occurred for both recalled and unrecalled memory items. Theoretical implications are discussed. PMID:17892393

  1. Event Related Potentials and Serial List Picture Memory in Parkinson’s Patients

    Directory of Open Access Journals (Sweden)

    M. S. Korsnes

    1996-01-01

    Full Text Available Two experiments examined short-term memory for order information in six patients diagnosed with Parkinson's disease (PD and six control subjects while event related potentials (ERPs were recorded. The subjects were tested for recognition of abstract spatial designs and words after a 5 s retention interval. The PD patients failed to respond in 29% of all trials, but the overall accuracy was similar to that in the control group when these trials were excluded. The corresponding ERP results show serial position variations both after presentation of the probe items, and after presentation of the memory set items. The amplitudes were generally lower at all positions for the PD patients at the parietal midline electrode, and the amplitudes were similar for both groups at the frontal electrode. Also, the ERP latencies were significantly slower for the PD patients than for the control group at all conditions. Indirectly the data are consistent with an interpretation of cognitive deficit in PD stressing attention resources.

  2. Event-related brain potentials for goal-related power grips.

    Science.gov (United States)

    Westerholz, Jan; Schack, Thomas; Koester, Dirk

    2013-01-01

    Recent research has shown that neurophysiological activation during action planning depends on the orientation to initial or final action goals for precision grips. However, the neural signature for a distinct class of grasping, power grips, is still unknown. The aim of the present study was to differentiate between cerebral activity, by means of event-related potentials (ERPs), and its temporal organization during power grips executed with an emphasis on either the initial or final parts of movement sequences. In a grasp and transportation task, visual cues emphasized either the grip (the immediate goal) or the target location (the final goal). ERPs differed between immediate and final goal-cued conditions, suggesting different means of operation dependent on goal-relatedness. Differences in mean amplitude occurred earlier for power grips than for recently reported precision grips time-locked to grasping over parieto-occipital areas. Time-locked to final object placement, differences occurred within a similar time window for power and precision grips over frontal areas. These results suggest that a parieto-frontal network of activation is of crucial importance for grasp planning and execution. Our results indicate that power grip preparation and execution for goal-related actions are controlled by similar neural mechanisms as have been observed during precision grips, but with a distinct temporal pattern.

  3. Do Event-Related Evoked Potentials Reflect Apathy Tendency and Motivation?

    Directory of Open Access Journals (Sweden)

    Hiroyuki Takayoshi

    2018-01-01

    Full Text Available Apathy is a mental state of diminished motivation. Although the reward system as the foundation of the motivation in the human brain has been studied extensively with neuroimaging techniques, the electrophysiological correlates of motivation and apathy have not been fully explored. Thus, in 14 healthy volunteers, we examined whether event-related evoked potentials (ERP obtained during a simple number discrimination task with/without rewards reflected apathy tendency and a reward-dependent tendency, which were assessed separately using the apathy scale and the temperament and character inventory (TCI. Participants were asked to judge the size of a number, and received feedback based on their performance in each trial. The P3 amplitudes related to the feedback stimuli increased only in the reward condition. Furthermore, the P2 amplitudes related to the negative feedback stimuli in the reward condition had a positive correlation with the reward-dependent tendency in TCI, whereas the P3 amplitudes related to the positive feedback stimuli had a negative correlation with the apathy score. Our result suggests that the P2 and P3 ERPs to reward-related feedback stimuli are modulated in a distinctive manner by the motivational reward dependence and apathy tendency, and thus the current paradigm may be useful for investigating the brain activity associated with motivation.

  4. Do Event-Related Evoked Potentials Reflect Apathy Tendency and Motivation?

    Science.gov (United States)

    Takayoshi, Hiroyuki; Onoda, Keiichi; Yamaguchi, Shuhei

    2018-01-01

    Apathy is a mental state of diminished motivation. Although the reward system as the foundation of the motivation in the human brain has been studied extensively with neuroimaging techniques, the electrophysiological correlates of motivation and apathy have not been fully explored. Thus, in 14 healthy volunteers, we examined whether event-related evoked potentials (ERP) obtained during a simple number discrimination task with/without rewards reflected apathy tendency and a reward-dependent tendency, which were assessed separately using the apathy scale and the temperament and character inventory (TCI). Participants were asked to judge the size of a number, and received feedback based on their performance in each trial. The P3 amplitudes related to the feedback stimuli increased only in the reward condition. Furthermore, the P2 amplitudes related to the negative feedback stimuli in the reward condition had a positive correlation with the reward-dependent tendency in TCI, whereas the P3 amplitudes related to the positive feedback stimuli had a negative correlation with the apathy score. Our result suggests that the P2 and P3 ERPs to reward-related feedback stimuli are modulated in a distinctive manner by the motivational reward dependence and apathy tendency, and thus the current paradigm may be useful for investigating the brain activity associated with motivation. PMID:29445331

  5. The application of particle filters in single trial event-related potential estimation

    International Nuclear Information System (INIS)

    Mohseni, Hamid R; Nazarpour, Kianoush; Sanei, Saeid; Wilding, Edward L

    2009-01-01

    In this paper, an approach for the estimation of single trial event-related potentials (ST-ERPs) using particle filters (PFs) is presented. The method is based on recursive Bayesian mean square estimation of ERP wavelet coefficients using their previous estimates as prior information. To enable a performance evaluation of the approach in the Gaussian and non-Gaussian distributed noise conditions, we added Gaussian white noise (GWN) and real electroencephalogram (EEG) signals recorded during rest to the simulated ERPs. The results were compared to that of the Kalman filtering (KF) approach demonstrating the robustness of the PF over the KF to the added GWN noise. The proposed method also outperforms the KF when the assumption about the Gaussianity of the noise is violated. We also applied this technique to real EEG potentials recorded in an odd-ball paradigm and investigated the correlation between the amplitude and the latency of the estimated ERP components. Unlike the KF method, for the PF there was a statistically significant negative correlation between amplitude and latency of the estimated ERPs, matching previous neurophysiological findings

  6. Toward brain-computer interface based wheelchair control utilizing tactually-evoked event-related potentials

    Science.gov (United States)

    2014-01-01

    Background People with severe disabilities, e.g. due to neurodegenerative disease, depend on technology that allows for accurate wheelchair control. For those who cannot operate a wheelchair with a joystick, brain-computer interfaces (BCI) may offer a valuable option. Technology depending on visual or auditory input may not be feasible as these modalities are dedicated to processing of environmental stimuli (e.g. recognition of obstacles, ambient noise). Herein we thus validated the feasibility of a BCI based on tactually-evoked event-related potentials (ERP) for wheelchair control. Furthermore, we investigated use of a dynamic stopping method to improve speed of the tactile BCI system. Methods Positions of four tactile stimulators represented navigation directions (left thigh: move left; right thigh: move right; abdomen: move forward; lower neck: move backward) and N = 15 participants delivered navigation commands by focusing their attention on the desired tactile stimulus in an oddball-paradigm. Results Participants navigated a virtual wheelchair through a building and eleven participants successfully completed the task of reaching 4 checkpoints in the building. The virtual wheelchair was equipped with simulated shared-control sensors (collision avoidance), yet these sensors were rarely needed. Conclusion We conclude that most participants achieved tactile ERP-BCI control sufficient to reliably operate a wheelchair and dynamic stopping was of high value for tactile ERP classification. Finally, this paper discusses feasibility of tactile ERPs for BCI based wheelchair control. PMID:24428900

  7. Optimal weighted averaging of event related activity from acquisitions with artifacts.

    Science.gov (United States)

    Vollero, Luca; Petrichella, Sara; Innello, Giulio

    2016-08-01

    In several biomedical applications that require the signal processing of biological data, the starting procedure for noise reduction is the ensemble averaging of multiple repeated acquisitions (trials). This method is based on the assumption that each trial is composed of two additive components: (i) a time-locked activity related to some sensitive/stimulation phenomenon (ERA, Event Related Activity in the following) and (ii) a sum of several other non time-locked background activities. The averaging aims at estimating the ERA activity under very low Signal to Noise and Interference Ratio (SNIR). Although averaging is a well established tool, its performance can be improved in the presence of high-power disturbances (artifacts) by a trials classification and removal stage. In this paper we propose, model and evaluate a new approach that avoids trials removal, managing trials classified as artifact-free and artifact-prone with two different weights. Based on the model, a weights tuning is possible and through modeling and simulations we show that, when optimally configured, the proposed solution outperforms classical approaches.

  8. Event-related potential evidence of form and meaning coding during online speech recognition.

    Science.gov (United States)

    Friedrich, Claudia K; Kotz, Sonja A

    2007-04-01

    It is still a matter of debate whether initial analysis of speech is independent of contextual influences or whether meaning can modulate word activation directly. Utilizing event-related brain potentials (ERPs), we tested the neural correlates of speech recognition by presenting sentences that ended with incomplete words, such as To light up the dark she needed her can-. Immediately following the incomplete words, subjects saw visual words that (i) matched form and meaning, such as candle; (ii) matched meaning but not form, such as lantern; (iii) matched form but not meaning, such as candy; or (iv) mismatched form and meaning, such as number. We report ERP evidence for two distinct cohorts of lexical tokens: (a) a left-lateralized effect, the P250, differentiates form-matching words (i, iii) and form-mismatching words (ii, iv); (b) a right-lateralized effect, the P220, differentiates words that match in form and/or meaning (i, ii, iii) from mismatching words (iv). Lastly, fully matching words (i) reduce the amplitude of the N400. These results accommodate bottom-up and top-down accounts of human speech recognition. They suggest that neural representations of form and meaning are activated independently early on and are integrated at a later stage during sentence comprehension.

  9. Dynamics of the spatial scale of visual attention revealed by brain event-related potentials

    Science.gov (United States)

    Luo, Y. J.; Greenwood, P. M.; Parasuraman, R.

    2001-01-01

    The temporal dynamics of the spatial scaling of attention during visual search were examined by recording event-related potentials (ERPs). A total of 16 young participants performed a search task in which the search array was preceded by valid cues that varied in size and hence in precision of target localization. The effects of cue size on short-latency (P1 and N1) ERP components, and the time course of these effects with variation in cue-target stimulus onset asynchrony (SOA), were examined. Reaction time (RT) to discriminate a target was prolonged as cue size increased. The amplitudes of the posterior P1 and N1 components of the ERP evoked by the search array were affected in opposite ways by the size of the precue: P1 amplitude increased whereas N1 amplitude decreased as cue size increased, particularly following the shortest SOA. The results show that when top-down information about the region to be searched is less precise (larger cues), RT is slowed and the neural generators of P1 become more active, reflecting the additional computations required in changing the spatial scale of attention to the appropriate element size to facilitate target discrimination. In contrast, the decrease in N1 amplitude with cue size may reflect a broadening of the spatial gradient of attention. The results provide electrophysiological evidence that changes in the spatial scale of attention modulate neural activity in early visual cortical areas and activate at least two temporally overlapping component processes during visual search.

  10. The event-related brain potential as an index of attention allocation in complex displays

    Science.gov (United States)

    Wickens, C. D.; Heffley, E. F.; Kramer, A. F.; Donchin, E.

    1980-01-01

    The advantages of employing the event-related brain potential (ERP) in the assessment of allocation of attention in dynamic environments are discussed. Three experiments are presented in which the P300 component of the ERP is demonstrated to be a useful index of subjects' locus of attention. The first two experiments were concerned with the allocation of attention during discrete and continuous visual monitoring tasks. The results indicated that a P300 was elicited only by stimuli to which the subject had to attend in order to perform successfully the task. The third experiment was conducted to assess the sensitivity of P300 to the manner in which attention is allocated to different aspects of a display during the performance of a 3-dimensional target acquisition task. The amplitude of the P300 was found to reflect differences between two levels of workload, as well as the task relevance of the stimuli. The results of the experiments are discussed in terms of their utility in the evaluation of the design of man-machine systems as well as in the study of the allocation of attention in operational environments.

  11. High density event-related potential data acquisition in cognitive neuroscience.

    Science.gov (United States)

    Slotnick, Scott D

    2010-04-16

    Functional magnetic resonance imaging (fMRI) is currently the standard method of evaluating brain function in the field of Cognitive Neuroscience, in part because fMRI data acquisition and analysis techniques are readily available. Because fMRI has excellent spatial resolution but poor temporal resolution, this method can only be used to identify the spatial location of brain activity associated with a given cognitive process (and reveals virtually nothing about the time course of brain activity). By contrast, event-related potential (ERP) recording, a method that is used much less frequently than fMRI, has excellent temporal resolution and thus can track rapid temporal modulations in neural activity. Unfortunately, ERPs are under utilized in Cognitive Neuroscience because data acquisition techniques are not readily available and low density ERP recording has poor spatial resolution. In an effort to foster the increased use of ERPs in Cognitive Neuroscience, the present article details key techniques involved in high density ERP data acquisition. Critically, high density ERPs offer the promise of excellent temporal resolution and good spatial resolution (or excellent spatial resolution if coupled with fMRI), which is necessary to capture the spatial-temporal dynamics of human brain function.

  12. Event-related alpha perturbations related to the scaling of steering wheel corrections.

    Science.gov (United States)

    Brooks, Justin; Kerick, Scott

    2015-10-01

    Previously we derived a new measure relating the driver's steering wheel responses to the vehicle's heading error velocity. This measure, the relative steering wheel compensation (RSWC), changes at times coincident with an alerting stimulus, possibly representing shifts in control strategy as measured by a change in the gain between visual input and motor output. In the present study, we sought to further validate this novel measure by determining the relationship between the RSWC and electroencephalogram (EEG) activity in brain regions associated with sensorimotor transformation processes. These areas have been shown to exhibit event-related spectral perturbation (ERSP) in the alpha frequency band that occurs with the onset of corrective steering wheel maneuvers in response to vehicle perturbations. We hypothesized that these regions would show differential alpha activity depending on whether the RSWC was high or low, reflecting changes in gain between visual input and motor output. Interestingly, we find that low RSWC is associated with significantly less peak desynchronization than larger RSWC. In addition we demonstrate that these differences are not attributable to the amount the steering wheel is turned nor the heading error velocity independently. Collectively these results suggest that neural activity in these sensorimotor regions scales with alertness and may represent differential utilization of multisensory information to control the steering wheel. Published by Elsevier Inc.

  13. Neural Basis of Intrinsic Motivation: Evidence from Event-Related Potentials.

    Science.gov (United States)

    Jin, Jia; Yu, Liping; Ma, Qingguo

    2015-01-01

    Human intrinsic motivation is of great importance in human behavior. However, although researchers have focused on this topic for decades, its neural basis was still unclear. The current study employed event-related potentials to investigate the neural disparity between an interesting stop-watch (SW) task and a boring watch-stop task (WS) to understand the neural mechanisms of intrinsic motivation. Our data showed that, in the cue priming stage, the cue of the SW task elicited smaller N2 amplitude than that of the WS task. Furthermore, in the outcome feedback stage, the outcome of the SW task induced smaller FRN amplitude and larger P300 amplitude than that of the WS task. These results suggested that human intrinsic motivation did exist and that it can be detected at the neural level. Furthermore, intrinsic motivation could be quantitatively indexed by the amplitude of ERP components, such as N2, FRN, and P300, in the cue priming stage or feedback stage. Quantitative measurements would also be convenient for intrinsic motivation to be added as a candidate social factor in the construction of a machine learning model.

  14. Person perception precedes theory of mind: an event related potential analysis.

    Science.gov (United States)

    Wang, Y W; Lin, C D; Yuan, B; Huang, L; Zhang, W X; Shen, D L

    2010-09-29

    Prior to developing an understanding of another person's mental state, an ability termed "theory of mind" (ToM), a perception of that person's appearance and actions is required. However the relationship between this "person perception" and ToM is unclear. To investigate the time course of ToM and person perception, event-related potentials (ERP) were recorded while 17 normal adults received three kinds of visual stimuli: cartoons involving people (person perception cartoons), cartoons involving people and also requiring ToM for comprehension (ToM cartoons), and scene cartoons. We hypothesized that the respective patterns of brain activation would be different under these three stimuli, at different stages in time. Our findings supported this proposal: the peak amplitudes of P200 for scene cartoons were significantly lower than for person perception or ToM cartoons, while there were no significant differences between the latter two for P200. During the 1000-1300 ms epoch, the mean amplitudes of the late positive components (LPC) for person perception were more positive than for scene representation, while the mean amplitudes of the LPC for ToM were more positive than for person perception. The present study provides preliminary evidence of the neural dynamic that underlies the dissociation between person perception and ToM. Copyright 2010 IBRO. Published by Elsevier Ltd. All rights reserved.

  15. Event-related brain responses while listening to entire pieces of music.

    Science.gov (United States)

    Poikonen, H; Alluri, V; Brattico, E; Lartillot, O; Tervaniemi, M; Huotilainen, M

    2016-01-15

    Brain responses to discrete short sounds have been studied intensively using the event-related potential (ERP) method, in which the electroencephalogram (EEG) signal is divided into epochs time-locked to stimuli of interest. Here we introduce and apply a novel technique which enables one to isolate ERPs in human elicited by continuous music. The ERPs were recorded during listening to a Tango Nuevo piece, a deep techno track and an acoustic lullaby. Acoustic features related to timbre, harmony, and dynamics of the audio signal were computationally extracted from the musical pieces. Negative deflation occurring around 100 milliseconds after the stimulus onset (N100) and positive deflation occurring around 200 milliseconds after the stimulus onset (P200) ERP responses to peak changes in the acoustic features were distinguishable and were often largest for Tango Nuevo. In addition to large changes in these musical features, long phases of low values that precede a rapid increase - and that we will call Preceding Low-Feature Phases - followed by a rapid increase enhanced the amplitudes of N100 and P200 responses. These ERP responses resembled those to simpler sounds, making it possible to utilize the tradition of ERP research with naturalistic paradigms. Crown Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

  16. Subliminal Emotional Words Impact Syntactic Processing: Evidence from Performance and Event-Related Brain Potentials

    Directory of Open Access Journals (Sweden)

    Laura Jiménez-Ortega

    2017-04-01

    Full Text Available Recent studies demonstrate that syntactic processing can be affected by emotional information and that subliminal emotional information can also affect cognitive processes. In this study, we explore whether unconscious emotional information may also impact syntactic processing. In an Event-Related brain Potential (ERP study, positive, neutral and negative subliminal adjectives were inserted within neutral sentences, just before the presentation of the supraliminal adjective. They could either be correct (50% or contain a morphosyntactic violation (number or gender disagreements. Larger error rates were observed for incorrect sentences than for correct ones, in contrast to most studies using supraliminal information. Strikingly, emotional adjectives affected the conscious syntactic processing of sentences containing morphosyntactic anomalies. The neutral condition elicited left anterior negativity (LAN followed by a P600 component. However, a lack of anterior negativity and an early P600 onset for the negative condition were found, probably as a result of the negative subliminal correct adjective capturing early syntactic resources. Positive masked adjectives in turn prompted an N400 component in response to morphosyntactic violations, probably reflecting the induction of a heuristic processing mode involving access to lexico-semantic information to solve agreement anomalies. Our results add to recent evidence on the impact of emotional information on syntactic processing, while showing that this can occur even when the reader is unaware of the emotional stimuli.

  17. Neural Basis of Intrinsic Motivation: Evidence from Event-Related Potentials

    Directory of Open Access Journals (Sweden)

    Jia Jin

    2015-01-01

    Full Text Available Human intrinsic motivation is of great importance in human behavior. However, although researchers have focused on this topic for decades, its neural basis was still unclear. The current study employed event-related potentials to investigate the neural disparity between an interesting stop-watch (SW task and a boring watch-stop task (WS to understand the neural mechanisms of intrinsic motivation. Our data showed that, in the cue priming stage, the cue of the SW task elicited smaller N2 amplitude than that of the WS task. Furthermore, in the outcome feedback stage, the outcome of the SW task induced smaller FRN amplitude and larger P300 amplitude than that of the WS task. These results suggested that human intrinsic motivation did exist and that it can be detected at the neural level. Furthermore, intrinsic motivation could be quantitatively indexed by the amplitude of ERP components, such as N2, FRN, and P300, in the cue priming stage or feedback stage. Quantitative measurements would also be convenient for intrinsic motivation to be added as a candidate social factor in the construction of a machine learning model.

  18. Do Event-Related Evoked Potentials Reflect Apathy Tendency and Motivation?

    Science.gov (United States)

    Takayoshi, Hiroyuki; Onoda, Keiichi; Yamaguchi, Shuhei

    2018-01-01

    Apathy is a mental state of diminished motivation. Although the reward system as the foundation of the motivation in the human brain has been studied extensively with neuroimaging techniques, the electrophysiological correlates of motivation and apathy have not been fully explored. Thus, in 14 healthy volunteers, we examined whether event-related evoked potentials (ERP) obtained during a simple number discrimination task with/without rewards reflected apathy tendency and a reward-dependent tendency, which were assessed separately using the apathy scale and the temperament and character inventory (TCI). Participants were asked to judge the size of a number, and received feedback based on their performance in each trial. The P3 amplitudes related to the feedback stimuli increased only in the reward condition. Furthermore, the P2 amplitudes related to the negative feedback stimuli in the reward condition had a positive correlation with the reward-dependent tendency in TCI, whereas the P3 amplitudes related to the positive feedback stimuli had a negative correlation with the apathy score. Our result suggests that the P2 and P3 ERPs to reward-related feedback stimuli are modulated in a distinctive manner by the motivational reward dependence and apathy tendency, and thus the current paradigm may be useful for investigating the brain activity associated with motivation.

  19. Short-term effects of prosocial video games on aggression: an event-related potential study.

    Science.gov (United States)

    Liu, Yanling; Teng, Zhaojun; Lan, Haiying; Zhang, Xin; Yao, Dezhong

    2015-01-01

    Previous research has shown that exposure to violent video games increases aggression, whereas exposure to prosocial video games can reduce aggressive behavior. However, little is known about the neural correlates of these behavioral effects. This work is the first to investigate the electrophysiological features of the relationship between playing a prosocial video game and inhibition of aggressive behavior. Forty-nine subjects played either a prosocial or a neutral video game for 20 min, then participated in an event-related potential (ERP) experiment based on an oddball paradigm and designed to test electrophysiological responses to prosocial and violent words. Finally, subjects completed a competitive reaction time task (CRTT) which based on Taylor's Aggression Paradigm and contains reaction time and noise intensity chosen as a measure of aggressive behavior. The results show that the prosocial video game group (compared to the neutral video game group) displayed smaller P300 amplitudes, were more accurate in distinguishing violent words, and were less aggressive as evaluated by the CRTT of noise intensity chosen. A mediation analysis shows that the P300 amplitude evoked by violent words partially mediates the relationship between type of video game and subsequent aggressive behavior. The results support theories based on the General Learning Model. We provide converging behavioral and neural evidence that exposure to prosocial media may reduce aggression.

  20. Snake scales, partial exposure, and the Snake Detection Theory: A human event-related potentials study

    Science.gov (United States)

    Van Strien, Jan W.; Isbell, Lynne A.

    2017-01-01

    Studies of event-related potentials in humans have established larger early posterior negativity (EPN) in response to pictures depicting snakes than to pictures depicting other creatures. Ethological research has recently shown that macaques and wild vervet monkeys respond strongly to partially exposed snake models and scale patterns on the snake skin. Here, we examined whether snake skin patterns and partially exposed snakes elicit a larger EPN in humans. In Task 1, we employed pictures with close-ups of snake skins, lizard skins, and bird plumage. In task 2, we employed pictures of partially exposed snakes, lizards, and birds. Participants watched a random rapid serial visual presentation of these pictures. The EPN was scored as the mean activity (225–300 ms after picture onset) at occipital and parieto-occipital electrodes. Consistent with previous studies, and with the Snake Detection Theory, the EPN was significantly larger for snake skin pictures than for lizard skin and bird plumage pictures, and for lizard skin pictures than for bird plumage pictures. Likewise, the EPN was larger for partially exposed snakes than for partially exposed lizards and birds. The results suggest that the EPN snake effect is partly driven by snake skin scale patterns which are otherwise rare in nature. PMID:28387376

  1. Rapid L2 Word Learning through High Constraint Sentence Context: An Event-Related Potential Study

    Directory of Open Access Journals (Sweden)

    Baoguo Chen

    2017-12-01

    Full Text Available Previous studies have found quantity of exposure, i.e., frequency of exposure (Horst et al., 1998; Webb, 2008; Pellicer-Sánchez and Schmitt, 2010, is important for second language (L2 contextual word learning. Besides this factor, context constraint and L2 proficiency level have also been found to affect contextual word learning (Pulido, 2003; Tekmen and Daloglu, 2006; Elgort et al., 2015; Ma et al., 2015. In the present study, we adopted the event-related potential (ERP technique and chose high constraint sentences as reading materials to further explore the effects of quantity of exposure and proficiency on L2 contextual word learning. Participants were Chinese learners of English with different English proficiency levels. For each novel word, there were four high constraint sentences with the critical word at the end of the sentence. Learners read sentences and made semantic relatedness judgment afterwards, with ERPs recorded. Results showed that in the high constraint condition where each pseudoword was embedded in four sentences with consistent meaning, N400 amplitude upon this pseudoword decreased significantly as learners read the first two sentences. High proficiency learners responded faster in the semantic relatedness judgment task. These results suggest that in high quality sentence contexts, L2 learners could rapidly acquire word meaning without multiple exposures, and L2 proficiency facilitated this learning process.

  2. An Event-Related Potential Study on the Effects of Cannabis on Emotion Processing

    Science.gov (United States)

    Troup, Lucy J.; Bastidas, Stephanie; Nguyen, Maia T.; Andrzejewski, Jeremy A.; Bowers, Matthew; Nomi, Jason S.

    2016-01-01

    The effect of cannabis on emotional processing was investigated using event-related potential paradigms (ERPs). ERPs associated with emotional processing of cannabis users, and non-using controls, were recorded and compared during an implicit and explicit emotional expression recognition and empathy task. Comparisons in P3 component mean amplitudes were made between cannabis users and controls. Results showed a significant decrease in the P3 amplitude in cannabis users compared to controls. Specifically, cannabis users showed reduced P3 amplitudes for implicit compared to explicit processing over centro-parietal sites which reversed, and was enhanced, at fronto-central sites. Cannabis users also showed a decreased P3 to happy faces, with an increase to angry faces, compared to controls. These effects appear to increase with those participants that self-reported the highest levels of cannabis consumption. Those cannabis users with the greatest consumption rates showed the largest P3 deficits for explicit processing and negative emotions. These data suggest that there is a complex relationship between cannabis consumption and emotion processing that appears to be modulated by attention. PMID:26926868

  3. Olfactory event-related potentials to amyl acetate in congenital anosmia.

    Science.gov (United States)

    Cui, L; Evans, W J

    1997-04-01

    Olfactory function was evaluated by olfactory event-related potentials and standardized psychophysical measures including the Smell Identification Test and odor detection threshold tests for 3 chemosensory stimulants in 9 subjects with isolated congenital anosmia and 9 age- and gender-matched normosmic controls. There was a significant difference in Smell Identification Test scores (P acetate (P amyl acetate and air control stimuli presented at volume flow rate of 5 l/min, stimulus duration of 40 ms, and randomized interstimulus intervals of 6-30 s. In the control subjects, evoked potentials to amyl acetate were characterized by 4 reproducible components (P1, N1, P2, and N2). In the subjects with congenital anosmia, no reproducible evoked potential components were identified in response to amyl acetate. No reproducible evoked potential components were seen in response to the air control stimulus in either the anosmic or normosmic groups. These data suggest that olfactory evoked potentials provide a specific measure of olfactory function.

  4. Subject Combination and Electrode Selection in Cooperative Brain-Computer Interface Based on Event Related Potentials

    Directory of Open Access Journals (Sweden)

    Hubert Cecotti

    2014-04-01

    Full Text Available New paradigms are required in Brain-Computer Interface (BCI systems for the needs and expectations of healthy people. To solve this issue, we explore the emerging field of cooperative BCIs, which involves several users in a single BCI system. Contrary to classical BCIs that are dependent on the unique subject’s will, cooperative BCIs are used for problem solving tasks where several people shall be engaged by sharing a common goal. Similarly as combining trials over time improves performance, combining trials across subjects can significantly improve performance compared with when only a single user is involved. Yet, cooperative BCIs may only be used in particular settings, and new paradigms must be proposed to efficiently use this approach. The possible benefits of using several subjects are addressed, and compared with current single-subject BCI paradigms. To show the advantages of a cooperative BCI, we evaluate the performance of combining decisions across subjects with data from an event-related potentials (ERP based experiment where each subject observed the same sequence of visual stimuli. Furthermore, we show that it is possible to achieve a mean AUC superior to 0.95 with 10 subjects and 3 electrodes on each subject, or with 4 subjects and 6 electrodes on each subject. Several emerging challenges and possible applications are proposed to highlight how cooperative BCIs could be efficiently used with current technologies and leverage BCI applications.

  5. Auditory event-related potential changes in chronic occupational exposure to organophosphate pesticides.

    Science.gov (United States)

    Dassanayake, T; Gawarammana, I B; Weerasinghe, V; Dissanayake, P S; Pragaash, S; Dawson, A; Senanayake, N

    2009-09-01

    To determine whether chronic occupational exposure to organophosphates (OP) pesticides leads to cognitive impairment using event-related potentials (ERPs). ERPs of 38 vegetable farmers applying OP pesticides and 35 controls were recorded using an auditory oddball paradigm. The N1, P2, N2 and P300 ERP components and the number of counting errors were compared between the groups. The farmers made significantly more counting errors than controls in the oddball task. The mixed model ANOVA of component latencies revealed a significant componentxgroup interaction, suggesting farmers had a greater delay in later ERP components. Intergroup comparisons of individual components showed significant delays in N2 and P300 latencies. Subsequent ANCOVA showed significant P300 delay even after adjusting for the latency of the preceding component, N2. Intergroup differences of P300 amplitudes were not significant, although there was limited evidence of a difference in scalp topography. Our findings indicate that chronic low-level occupational exposure to OP pesticides is associated with progressively increasing delay in successive ERP components, particularly P300. Chronic exposure to OP pesticides may delay the neurophysiological processes underlying early stages of selective attention and late stages of sensory information processing that include stimulus evaluation and updating of working memory.

  6. Evaluation of auditory perception development in neonates by event-related potential technique.

    Science.gov (United States)

    Zhang, Qinfen; Li, Hongxin; Zheng, Aibin; Dong, Xuan; Tu, Wenjuan

    2017-08-01

    To investigate auditory perception development in neonates and correlate it with days after birth, left and right hemisphere development and sex using event-related potential (ERP) technique. Sixty full-term neonates, consisting of 32 males and 28 females, aged 2-28days were included in this study. An auditory oddball paradigm was used to elicit ERPs. N2 wave latencies and areas were recorded at different days after birth, to study on relationship between auditory perception and age, and comparison of left and right hemispheres, and males and females. Average wave forms of ERPs in neonates started from relatively irregular flat-bottomed troughs to relatively regular steep-sided ripples. A good linear relationship between ERPs and days after birth in neonates was observed. As days after birth increased, N2 latencies gradually and significantly shortened, and N2 areas gradually and significantly increased (both Pauditory perception development. In the days following birth, the auditory perception ability of neonates gradually increases. This occurs predominantly in the left hemisphere, with auditory perception ability appearing to develop earlier in female neonates than in males. ERP can be used as an objective index used to evaluate auditory perception development in neonates. Copyright © 2017 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.

  7. Tracking cognitive phases in analogical reasoning with event-related potentials.

    Science.gov (United States)

    Maguire, Mandy J; McClelland, M Michelle; Donovan, Colin M; Tillman, Gail D; Krawczyk, Daniel C

    2012-03-01

    Analogical reasoning consists of multiple phases. Four-term analogies (A:B::C:D) have an encoding period in which the A:B pair is evaluated prior to a mapping phase. The electrophysiological timing associated with analogical reasoning has remained unclear. We used event-related potentials to identify neural timing related to analogical reasoning relative to perceptual and semantic control conditions. Spatiotemporal principal-components analyses revealed differences primarily in left frontal electrodes during encoding and mapping phases of analogies relative to the other conditions. The timing of the activity differed depending upon the phase of the problem. During the encoding of A:B terms, analogies elicited a positive deflection compared to the control conditions between 400 and 1,200 ms, but for the mapping phase analogical processing elicited a negative deflection that occurred earlier and for a shorter time period, between 350 and 625 ms. These results provide neural and behavioral evidence that 4-term analogy problems involve a highly active evaluation phase of the A:B pair. 2012 APA, all rights reserved

  8. Relating derived relations as a model of analogical reasoning: reaction times and event-related potentials.

    Science.gov (United States)

    Barnes-Holmes, Dermot; Regan, Donal; Barnes-Holmes, Yvonne; Commins, Sean; Walsh, Derek; Stewart, Ian; Smeets, Paul M; Whelan, Robert; Dymond, Simon

    2005-11-01

    The current study aimed to test a Relational Frame Theory (RFT) model of analogical reasoning based on the relating of derived same and derived difference relations. Experiment 1 recorded reaction time measures of similar-similar (e.g., "apple is to orange as dog is to cat") versus different-different (e.g., "he is to his brother as chalk is to cheese") derived relational responding, in both speed-contingent and speed-noncontingent conditions. Experiment 2 examined the event-related potentials (ERPs) associated with these two response patterns. Both experiments showed similar-similar responding to be significantly faster than different-different responding. Experiment 2 revealed significant differences between the waveforms of the two response patterns in the left-hemispheric prefrontal regions; different-different waveforms were significantly more negative than similar-similar waveforms. The behavioral and neurophysiological data support the RFT prediction that, all things being equal, similar-similar responding is relationally "simpler" than, and functionally distinct from, different-different analogical responding. The ERP data were fully consistent with findings in the neurocognitive literature on analogy. These findings strengthen the validity of the RFT model of analogical reasoning and supplement the behavior-analytic approach to analogy based on the relating of derived relations.

  9. Event-related brain responses to emotional words, pictures, and faces - a cross-domain comparison.

    Science.gov (United States)

    Bayer, Mareike; Schacht, Annekathrin

    2014-01-01

    Emotion effects in event-related brain potentials (ERPs) have previously been reported for a range of visual stimuli, including emotional words, pictures, and facial expressions. Still, little is known about the actual comparability of emotion effects across these stimulus classes. The present study aimed to fill this gap by investigating emotion effects in response to words, pictures, and facial expressions using a blocked within-subject design. Furthermore, ratings of stimulus arousal and valence were collected from an independent sample of participants. Modulations of early posterior negativity (EPN) and late positive complex (LPC) were visible for all stimulus domains, but showed clear differences, particularly in valence processing. While emotion effects were limited to positive stimuli for words, they were predominant for negative stimuli in pictures and facial expressions. These findings corroborate the notion of a positivity offset for words and a negativity bias for pictures and facial expressions, which was assumed to be caused by generally lower arousal levels of written language. Interestingly, however, these assumed differences were not confirmed by arousal ratings. Instead, words were rated as overall more positive than pictures and facial expressions. Taken together, the present results point toward systematic differences in the processing of written words and pictorial stimuli of emotional content, not only in terms of a valence bias evident in ERPs, but also concerning their emotional evaluation captured by ratings of stimulus valence and arousal.

  10. Event-related brain potential correlates of human auditory sensory memory-trace formation.

    Science.gov (United States)

    Haenschel, Corinna; Vernon, David J; Dwivedi, Prabuddh; Gruzelier, John H; Baldeweg, Torsten

    2005-11-09

    The event-related potential (ERP) component mismatch negativity (MMN) is a neural marker of human echoic memory. MMN is elicited by deviant sounds embedded in a stream of frequent standards, reflecting the deviation from an inferred memory trace of the standard stimulus. The strength of this memory trace is thought to be proportional to the number of repetitions of the standard tone, visible as the progressive enhancement of MMN with number of repetitions (MMN memory-trace effect). However, no direct ERP correlates of the formation of echoic memory traces are currently known. This study set out to investigate changes in ERPs to different numbers of repetitions of standards, delivered in a roving-stimulus paradigm in which the frequency of the standard stimulus changed randomly between stimulus trains. Normal healthy volunteers (n = 40) were engaged in two experimental conditions: during passive listening and while actively discriminating changes in tone frequency. As predicted, MMN increased with increasing number of standards. However, this MMN memory-trace effect was caused mainly by enhancement with stimulus repetition of a slow positive wave from 50 to 250 ms poststimulus in the standard ERP, which is termed here "repetition positivity" (RP). This RP was recorded from frontocentral electrodes when participants were passively listening to or actively discriminating changes in tone frequency. RP may represent a human ERP correlate of rapid and stimulus-specific adaptation, a candidate neuronal mechanism underlying sensory memory formation in the auditory cortex.

  11. Can echoic memory store two traces simultaneously? A study of event-related brain potentials.

    Science.gov (United States)

    Winkler, I; Paavilainen, P; Näätänen, R

    1992-05-01

    The mismatch negativity, a component of the event-related brain potential elicited by infrequent deviants in sequences of auditory stimuli, is presumably generated by an automatic mismatch process in a mechanism that compares the current stimulus to the trace of the previous one. The present study addressed the possible simultaneous existence of two such traces. Two equiprobable (45% each) frequent stimuli ("standards"), one of 600 Hz and the other of 700 Hz, were presented together with an infrequent (10%), "deviant" stimulus which was of different frequency in different blocks. These deviants elicited a mismatch negativity, though a smaller one than that obtained in corresponding blocks with only one standard stimulus. Two aspects of the present results from the blocks with two standard stimuli implicate two parallel stimulus traces in these blocks: 1) deviants elicited a mismatch negativity (MMN) of approximately the same amplitude when preceded by sequences of four identical standards as when preceded by sequences of four stimuli containing both standards; 2) in contrast to the one-standard condition, the magnitude of stimulus deviance did not affect the MMN component elicited by the different deviants.

  12. Auditory event-related potentials in children with benign epilepsy with centro-temporal spikes.

    Science.gov (United States)

    Tomé, David; Sampaio, Mafalda; Mendes-Ribeiro, José; Barbosa, Fernando; Marques-Teixeira, João

    2014-12-01

    Benign focal epilepsy in childhood with centro-temporal spikes (BECTS) is one of the most common forms of idiopathic epilepsy, with onset from age 3 to 14 years. Although the prognosis for children with BECTS is excellent, some studies have revealed neuropsychological deficits in many domains, including language. Auditory event-related potentials (AERPs) reflect activation of different neuronal populations and are suggested to contribute to the evaluation of auditory discrimination (N1), attention allocation and phonological categorization (N2), and echoic memory (mismatch negativity--MMN). The scarce existing literature about this theme motivated the present study, which aims to investigate and document the existing AERP changes in a group of children with BECTS. AERPs were recorded, during the day, to pure and vocal tones and in a conventional auditory oddball paradigm in five children with BECTS (aged 8-12; mean=10 years; male=5) and in six gender and age-matched controls. Results revealed high amplitude of AERPs for the group of children with BECTS with a slight latency delay more pronounced in fronto-central electrodes. Children with BECTS may have abnormal central auditory processing, reflected by electrophysiological measures such as AERPs. In advance, AERPs seem a good tool to detect and reliably reveal cortical excitability in children with typical BECTS. Copyright © 2014 Elsevier B.V. All rights reserved.

  13. Event-related potential correlates of long-term memory for briefly presented faces.

    Science.gov (United States)

    Joyce, Carrie A; Kutas, Marta

    2005-05-01

    Electrophysiological studies have investigated the nature of face recognition in a variety of paradigms; some have contrasted famous and novel faces in explicit memory paradigms, others have repeated faces to examine implicit memory/priming. If the general finding that implicit memory can last for up to several months also holds for novel faces, a reliable measure of it could have practical application for eyewitness testimony, given that explicit measures of eyewitness memory have at times proven fallible. The current study aimed to determine whether indirect behavioral and electrophysiological measures might yield reliable estimates of face memory over longer intervals than have typically been obtained with priming manipulations. Participants were shown 192 faces and then tested for recognition at four test delays ranging from immediately up to 1 week later. Three event-related brain potential components (e.g., N250r, N400f, and LPC) varied with memory measures although only the N250r varied regardless of explicit recognition, that is, with both repetition and recognition.

  14. Cortical excitability correlates with the event-related desynchronization during brain-computer interface control

    Science.gov (United States)

    Daly, Ian; Blanchard, Caroline; Holmes, Nicholas P.

    2018-04-01

    Objective. Brain-computer interfaces (BCIs) based on motor control have been suggested as tools for stroke rehabilitation. Some initial successes have been achieved with this approach, however the mechanism by which they work is not yet fully understood. One possible part of this mechanism is a, previously suggested, relationship between the strength of the event-related desynchronization (ERD), a neural correlate of motor imagination and execution, and corticospinal excitability. Additionally, a key component of BCIs used in neurorehabilitation is the provision of visual feedback to positively reinforce attempts at motor control. However, the ability of visual feedback of the ERD to modulate the activity in the motor system has not been fully explored. Approach. We investigate these relationships via transcranial magnetic stimulation delivered at different moments in the ongoing ERD related to hand contraction and relaxation during BCI control of a visual feedback bar. Main results. We identify a significant relationship between ERD strength and corticospinal excitability, and find that our visual feedback does not affect corticospinal excitability. Significance. Our results imply that efforts to promote functional recovery in stroke by targeting increases in corticospinal excitability may be aided by accounting for the time course of the ERD.

  15. EEG Channel Selection Using Particle Swarm Optimization for the Classification of Auditory Event-Related Potentials

    Directory of Open Access Journals (Sweden)

    Alejandro Gonzalez

    2014-01-01

    Full Text Available Brain-machine interfaces (BMI rely on the accurate classification of event-related potentials (ERPs and their performance greatly depends on the appropriate selection of classifier parameters and features from dense-array electroencephalography (EEG signals. Moreover, in order to achieve a portable and more compact BMI for practical applications, it is also desirable to use a system capable of accurate classification using information from as few EEG channels as possible. In the present work, we propose a method for classifying P300 ERPs using a combination of Fisher Discriminant Analysis (FDA and a multiobjective hybrid real-binary Particle Swarm Optimization (MHPSO algorithm. Specifically, the algorithm searches for the set of EEG channels and classifier parameters that simultaneously maximize the classification accuracy and minimize the number of used channels. The performance of the method is assessed through offline analyses on datasets of auditory ERPs from sound discrimination experiments. The proposed method achieved a higher classification accuracy than that achieved by traditional methods while also using fewer channels. It was also found that the number of channels used for classification can be significantly reduced without greatly compromising the classification accuracy.

  16. Comparison of Auditory Event-Related Potential P300 in Sighted and Early Blind Individuals

    Directory of Open Access Journals (Sweden)

    Fatemeh Heidari

    2010-06-01

    Full Text Available Background and Aim: Following an early visual deprivation, the neural network involved in processing auditory spatial information undergoes a profound reorganization. In order to investigate this process, event-related potentials provide accurate information about time course neural activation as well as perception and cognitive processes. In this study, the latency and amplitude of auditory P300 were compared in sighted and early blind individuals in age range of 18-25 years old.Methods: In this cross-sectional study, auditory P300 potential was measured in conventional oddball paradigm by using two tone burst stimuli (1000 and 2000 Hz on 40 sighted subjects and 19 early blind subjects with mean age 20.94 years old.Results: The mean latency of P300 in early blind subjects was significantly smaller than sighted subjects (p=0.00.( There was no significant difference in amplitude between two groups (p>0.05.Conclusion: Reduced latency of P300 in early blind subjects in comparison to sighted subjects probably indicates the rate of automatic processing and information categorization is faster in early blind subjects because of sensory compensation. It seems that neural plasticity increases the rate of auditory processing and attention in early blind subjects.

  17. Time-Frequency Data Reduction for Event Related Potentials: Combining Principal Component Analysis and Matching Pursuit

    Directory of Open Access Journals (Sweden)

    Selin Aviyente

    2010-01-01

    Full Text Available Joint time-frequency representations offer a rich representation of event related potentials (ERPs that cannot be obtained through individual time or frequency domain analysis. This representation, however, comes at the expense of increased data volume and the difficulty of interpreting the resulting representations. Therefore, methods that can reduce the large amount of time-frequency data to experimentally relevant components are essential. In this paper, we present a method that reduces the large volume of ERP time-frequency data into a few significant time-frequency parameters. The proposed method is based on applying the widely used matching pursuit (MP approach, with a Gabor dictionary, to principal components extracted from the time-frequency domain. The proposed PCA-Gabor decomposition is compared with other time-frequency data reduction methods such as the time-frequency PCA approach alone and standard matching pursuit methods using a Gabor dictionary for both simulated and biological data. The results show that the proposed PCA-Gabor approach performs better than either the PCA alone or the standard MP data reduction methods, by using the smallest amount of ERP data variance to produce the strongest statistical separation between experimental conditions.

  18. An event-related potential study of maternal love in mothers.

    Science.gov (United States)

    Lu, Jiamei; Li, Da; Xu, Jingwei

    2012-10-01

    Feeling is stable and implicit and can be explicated in concrete situations in the form of emotion. To map the time course of feeling processing, the present study explored electrophysiological responses relevant to inner feeling by creating situations to evoke the explicit response of feeling. Fourteen mothers were asked to listen to TS and NS. Although the early event-related potential components (P1, N1 and P2) elicited by story pictures were not affected by the emotional valence of stories, the pictures relevant to TS elicited larger P3 and late positive potential (LPP) components than did neutral story pictures, indicating that feeling processing occurred at the post-perceptual stage. Feeling-related positive potential was separated using the difference wave analysis technique, which consisted of two sub-components: FRBB1 and FRBB2 based on P3 and LPP modulations, respectively. These data provide new electrophysiological evidence for the time course of feeling processing related to maternal love.

  19. Analysis of events related to cracks and leaks in the reactor coolant pressure boundary

    Energy Technology Data Exchange (ETDEWEB)

    Ballesteros, Antonio, E-mail: Antonio.Ballesteros-Avila@ec.europa.eu [JRC-IET: Institute for Energy and Transport of the Joint Research Centre of the European Commission, Postbus 2, NL-1755 ZG Petten (Netherlands); Sanda, Radian; Peinador, Miguel; Zerger, Benoit [JRC-IET: Institute for Energy and Transport of the Joint Research Centre of the European Commission, Postbus 2, NL-1755 ZG Petten (Netherlands); Negri, Patrice [IRSN: Institut de Radioprotection et de Sûreté Nucléaire (France); Wenke, Rainer [GRS: Gesellschaft für Anlagen- und Reaktorsicherheit (GRS) mbH (Germany)

    2014-08-15

    Highlights: • The important role of Operating Experience Feedback is emphasised. • Events relating to cracks and leaks in the reactor coolant pressure boundary are analysed. • A methodology for event investigation is described. • Some illustrative results of the analysis of events for specific components are presented. - Abstract: The presence of cracks and leaks in the reactor coolant pressure boundary may jeopardise the safe operation of nuclear power plants. Analysis of cracks and leaks related events is an important task for the prevention of their recurrence, which should be performed in the context of activities on Operating Experience Feedback. In response to this concern, the EU Clearinghouse operated by the JRC-IET supports and develops technical and scientific work to disseminate the lessons learned from past operating experience. In particular, concerning cracks and leaks, the studies carried out in collaboration with IRSN and GRS have allowed to identify the most sensitive areas to degradation in the plant primary system and to elaborate recommendations for upgrading the maintenance, ageing management and inspection programmes. An overview of the methodology used in the analysis of cracks and leaks related events is presented in this paper, together with the relevant results obtained in the study.

  20. The taste-visual cross-modal Stroop effect: An event-related brain potential study.

    Science.gov (United States)

    Xiao, X; Dupuis-Roy, N; Yang, X L; Qiu, J F; Zhang, Q L

    2014-03-28

    Event-related potentials (ERPs) were recorded to explore, for the first time, the electrophysiological correlates of the taste-visual cross-modal Stroop effect. Eighteen healthy participants were presented with a taste stimulus and a food image, and asked to categorize the image as "sweet" or "sour" by pressing the relevant button as quickly as possible. Accurate categorization of the image was faster when it was presented with a congruent taste stimulus (e.g., sour taste/image of lemon) than with an incongruent one (e.g., sour taste/image of ice cream). ERP analyses revealed a negative difference component (ND430-620) between 430 and 620ms in the taste-visual cross-modal Stroop interference. Dipole source analysis of the difference wave (incongruent minus congruent) indicated that two generators localized in the prefrontal cortex and the parahippocampal gyrus contributed to this taste-visual cross-modal Stroop effect. This result suggests that the prefrontal cortex is associated with the process of conflict control in the taste-visual cross-modal Stroop effect. Also, we speculate that the parahippocampal gyrus is associated with the process of discordant information in the taste-visual cross-modal Stroop effect. Copyright © 2014 IBRO. Published by Elsevier Ltd. All rights reserved.

  1. Event-related potentials elicited by social commerce and electronic-commerce reviews.

    Science.gov (United States)

    Bai, Yan; Yao, Zhong; Cong, Fengyu; Zhang, Linlin

    2015-12-01

    There is an increasing interest regarding the use of electroencephalography (EEG) in social commerce and electronic commerce (e-commerce) research. There are several reviews in the field of social commerce or e-commerce; these have great potential value and mining them is fundamental and significant. To our knowledge, EEG is rarely applied to study these. In this study, we examined the neural correlates of social commerce reviews (SCRs) and e-commerce reviews (ECRs) by using them as stimuli to evoke event-related potentials. All SCRs were from friends through a social media platform, whereas ECRs were from strangers through an e-commerce platform. The experimental design was similar to that of a priming paradigm, and included 40 pairs of stimuli consisting of product information (prime stimulus) and reviews (target stimulus). The results showed that the P300 component was successfully evoked by SCR and ECR stimuli. Moreover, the P300 components elicited by SCRs had higher amplitudes than those elicited by ECRs. These findings indicate that participants paid more attention to SCRs than to ECRs. In addition, the associations between neural responses and reviews in social commerce have the potential to assist companies in studying consumer behaviors, thus permitting them to enhance their social commerce strategies.

  2. Auditory event-related potentials associated with perceptual reversals of bistable pitch motion

    Directory of Open Access Journals (Sweden)

    Gray D. Davidson

    2014-08-01

    Full Text Available Previous event-related potential (ERP experiments have consistently identified two components associated with perceptual transitions of bistable visual stimuli, the reversal negativity (RN and the late positive complex (LPC. The RN (~200ms post-stimulus, bilateral occipital-parietal distribution is thought to reflect transitions between neural representations that form the moment-to-moment contents of conscious perception, while the LPC (~400ms, central-parietal is considered an index of post-perceptual processing related to accessing and reporting one’s percept. To explore the generality of these components across sensory modalities, the present experiment utilized a novel bistable auditory stimulus. Pairs of complex tones with ambiguous pitch relationships were presented sequentially while subjects reported whether they perceived the tone pairs as ascending or descending in pitch. ERPs elicited by the tones were compared according to whether perceived pitch motion changed direction or remained the same across successive trials. An auditory RN component (aRN was evident at ~170ms post-stimulus over bilateral fronto-central scalp locations. An auditory LPC component (aLPC was evident at subsequent latencies (~350ms, fronto-central distribution. These two components may be auditory analogs of the visual RN and LPC, suggesting functionally equivalent but anatomically distinct processes in auditory versus visual bistable perception.

  3. Processing statistics: an examination of focused and distributed attention using event related potentials.

    Science.gov (United States)

    Baijal, Shruti; Nakatani, Chie; van Leeuwen, Cees; Srinivasan, Narayanan

    2013-06-07

    Human observers show remarkable efficiency in statistical estimation; they are able, for instance, to estimate the mean size of visual objects, even if their number exceeds the capacity limits of focused attention. This ability has been understood as the result of a distinct mode of attention, i.e. distributed attention. Compared to the focused attention mode, working memory representations under distributed attention are proposed to be more compressed, leading to reduced working memory loads. An alternate proposal is that distributed attention uses less structured, feature-level representations. These would fill up working memory (WM) more, even when target set size is low. Using event-related potentials, we compared WM loading in a typical distributed attention task (mean size estimation) to that in a corresponding focused attention task (object recognition), using a measure called contralateral delay activity (CDA). Participants performed both tasks on 2, 4, or 8 different-sized target disks. In the recognition task, CDA amplitude increased with set size; notably, however, in the mean estimation task the CDA amplitude was high regardless of set size. In particular for set-size 2, the amplitude was higher in the mean estimation task than in the recognition task. The result showed that the task involves full WM loading even with a low target set size. This suggests that in the distributed attention mode, representations are not compressed, but rather less structured than under focused attention conditions. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Sleep inertia and autonomic effects on post-nap P300 event-related potential.

    Science.gov (United States)

    Takahashi, M; Arito, H

    1998-10-01

    The objective of this study was to examine the relationship between post-nap measures of alertness and performance and non-rapid eye movement (NREM) sleep and parasympathetic activity during brief naps. Thirty healthy subjects were randomly assigned to no-nap, 15-min, and 45-min nap conditions after normal home sleep at prior night. Each nap was taken after lunch and monitored by electroencephalogram (EEG), electromyogram, electrooculogram, and electrocardiogram (ECG). Deep NREM sleep was quantified by EEG delta power density and the parasympathetic activity was quantified by the ECG high-frequency (HF) component of R-R interval variability during the 15- and 45-min naps. The P300 event-related potential, subjective sleepiness, and performance on a 90-min English transcription task were measured 30 min and 3 hr after the naps and tested for their association with the EEG and ECG measures. A positive correlation was obtained between EEG delta power density during the naps and P300 latency 30 min after the naps (r = 0.476, p sleep inertia prolongs the P300 latency immediately after the naps, and that the parasympathetic predominance during the naps may improve subsequent alertness as assessed by the shortened P300 latency 3 hr after the naps.

  5. Inhibitory control in bilinguals and musicians: event related potential (ERP evidence for experience-specific effects.

    Directory of Open Access Journals (Sweden)

    Sylvain Moreno

    Full Text Available Bilinguals and musicians exhibit behavioral advantages on tasks with high demands on executive functioning, particularly inhibitory control, but the brain mechanisms supporting these differences are unclear. Of key interest is whether these forms of experience influence cognition through similar or distinct information processing mechanisms. Here, we recorded event-related potentials (ERPs in three groups - bilinguals, musicians, and controls - who completed a visual go-nogo task that involved the withholding of key presses to rare targets. Participants in each group achieved similar accuracy rates and responses times but the analysis of cortical responses revealed significant differences in ERP waveforms. Success in withholding a prepotent response was associated with enhanced stimulus-locked N2 and P3 wave amplitude relative to go trials. For nogo trials, there were altered timing-specific ERP differences and graded amplitude differences observed in the neural responses across groups. Specifically, musicians showed an enhanced early P2 response accompanied by reduced N2 amplitude whereas bilinguals showed increased N2 amplitude coupled with an increased late positivity wave relative to controls. These findings demonstrate that bilingualism and music training have differential effects on the brain networks supporting executive control over behavior.

  6. A hierarchy of event-related potential markers of auditory processing in disorders of consciousness

    Directory of Open Access Journals (Sweden)

    Steve Beukema

    2016-01-01

    Full Text Available Functional neuroimaging of covert perceptual and cognitive processes can inform the diagnoses and prognoses of patients with disorders of consciousness, such as the vegetative and minimally conscious states (VS;MCS. Here we report an event-related potential (ERP paradigm for detecting a hierarchy of auditory processes in a group of healthy individuals and patients with disorders of consciousness. Simple cortical responses to sounds were observed in all 16 patients; 7/16 (44% patients exhibited markers of the differential processing of speech and noise; and 1 patient produced evidence of the semantic processing of speech (i.e. the N400 effect. In several patients, the level of auditory processing that was evident from ERPs was higher than the abilities that were evident from behavioural assessment, indicating a greater sensitivity of ERPs in some cases. However, there were no differences in auditory processing between VS and MCS patient groups, indicating a lack of diagnostic specificity for this paradigm. Reliably detecting semantic processing by means of the N400 effect in passively listening single-subjects is a challenge. Multiple assessment methods are needed in order to fully characterise the abilities of patients with disorders of consciousness.

  7. Alcohol Preferences and Event-Related Potentials to Alcohol Images in College Students.

    Science.gov (United States)

    Thurin, Kyle; Ceballos, Natalie A; Graham, Reiko

    2017-11-01

    Research on attentional biases to alcohol images has used heterogeneous sets of stimuli (e.g., an isolated beer can or a group of people drinking). However, alcoholic beverage preferences play an important part in determining an individual's alcohol use pattern and may influence attentional biases, especially for inexperienced drinkers. The current study examined whether alcoholic beverage preferences affect event-related potential (ERP) indices of cue reactivity to different types of alcohol images (e.g., beer, wine, and distilled spirits) in heavy episodic drinkers. ERPs were recorded in 14 heavy episodic drinkers (7 male) who completed a Go/No-Go task using preferred and nonpreferred alcohol images with nonalcoholic beverage images as controls. Larger N2 amplitudes for preferred alcohol images were observed relative to control images and to nonpreferred alcohol images, indicating increased attentional capture by preferred beverages. P3 amplitudes and latencies were not sensitive to preferences, but latencies were delayed and amplitudes were enhanced on No-Go trials (i.e., trials requiring response inhibition). These results suggest that alcoholic beverage preference is a factor influencing alcohol cue reactivity in heavy-episodic-drinking college students. This information has methodological significance and may also be applied to improve treatment and prevention programs that focus on attentional bias modification and inhibitory control training.

  8. Gender differences in memory processing of female facial attractiveness: evidence from event-related potentials.

    Science.gov (United States)

    Zhang, Yan; Wei, Bin; Zhao, Peiqiong; Zheng, Minxiao; Zhang, Lili

    2016-06-01

    High rates of agreement in the judgment of facial attractiveness suggest universal principles of beauty. This study investigated gender differences in recognition memory processing of female facial attractiveness. Thirty-four Chinese heterosexual participants (17 females, 17 males) aged 18-24 years (mean age 21.63 ± 1.51 years) participated in the experiment which used event-related potentials (ERPs) based on a study-test paradigm. The behavioral data results showed that both men and women had significantly higher accuracy rates for attractive faces than for unattractive faces, but men reacted faster to unattractive faces. Gender differences on ERPs showed that attractive faces elicited larger early components such as P1, N170, and P2 in men than in women. The results indicated that the effects of recognition bias during memory processing modulated by female facial attractiveness are greater for men than women. Behavioral and ERP evidences indicate that men and women differ in their attentional adhesion to attractive female faces; different mating-related motives may guide the selective processing of attractive men and women. These findings establish a contribution of gender differences on female facial attractiveness during memory processing from an evolutionary perspective.

  9. An Event-Related Study for Dynamic Analysis of Corticomuscular Connectivity

    Directory of Open Access Journals (Sweden)

    Ou Bai

    2010-01-01

    Full Text Available Corticomuscular coupling estimated by EEG-EMG coherence may reveal functional cortical driving of peripheral muscular activity. EEG-EMG coherence in the beta band (15–30 Hz has been extensively studied under isometric muscle contraction tasks. We attempted to study the time-course of corticomuscular connectivity under a dynamic target tracking task. A new device was developed for the real-time measurement of dynamic force created by pinching thumb and index fingers. Four healthy subjects who participated in this study were asked to track visual targets with the feedback forces. Spectral parameters using FFT and complex wavelet were explored for reliable estimation of event-related coherence and EEG-EMG correlogram for representing corticomuscular connectivity. Clearly distinguishable FFT-based coherence and cross-correlogram during the visual target tracking were observed with appropriate hyper-parameters for spectral estimation. The system design and the exploration of signal processing methods in this study supports further exploration of corticomuscular connectivity associated with human motor control.

  10. Lexical ambiguity resolution during sentence processing in Parkinson's disease: An event-related potential study.

    Directory of Open Access Journals (Sweden)

    Anthony J Angwin

    Full Text Available Event-related potentials (ERPs were recorded to investigate lexical ambiguity resolution during sentence processing in 16 people with Parkinson's disease (PD and 16 healthy controls. Sentences were presented word-by-word on computer screen, and participants were required to decide if a subsequent target word was related to the meaning of the sentence. The task consisted of related, unrelated and ambiguous trials. For the ambiguous trials, the sentence ended with an ambiguous word and the target was related to one of the meanings of that word, but not the one captured by the sentence context (e.g., 'He dug with the spade', Target 'ACE'. Both groups demonstrated slower reaction times and lower accuracy for the ambiguous condition relative to the unrelated condition, however accuracy was impacted by the ambiguous condition to a larger extent in the PD group. These results suggested that PD patients experience increased difficulties with contextual ambiguity resolution. The ERP results did not reflect increased ambiguity resolution difficulties in PD, as a similar N400 effect was evident for the unrelated and ambiguous condition in both groups. However, the magnitude of the N400 for these conditions was correlated with a measure of inhibition in the PD group, but not the control group. The ERP results suggest that semantic processing may be more compromised in PD patients with increased response inhibition deficits.

  11. Temporal characteristics of online syntactic sentence planning: an event-related potential study.

    Science.gov (United States)

    Timmers, Inge; Gentile, Francesco; Rubio-Gozalbo, M Estela; Jansma, Bernadette M

    2013-01-01

    During sentence production, linguistic information (semantics, syntax, phonology) of words is retrieved and assembled into a meaningful utterance. There is still debate on how we assemble single words into more complex syntactic structures such as noun phrases or sentences. In the present study, event-related potentials (ERPs) were used to investigate the time course of syntactic planning. Thirty-three volunteers described visually animated scenes using naming formats varying in syntactic complexity: from simple words ('W', e.g., "triangle", "red", "square", "green", "to fly towards"), to noun phrases ('NP', e.g., "the red triangle", "the green square", "to fly towards"), to a sentence ('S', e.g., "The red triangle flies towards the green square."). Behaviourally, we observed an increase in errors and corrections with increasing syntactic complexity, indicating a successful experimental manipulation. In the ERPs following scene onset, syntactic complexity variations were found in a P300-like component ('S'/'NP'>'W') and a fronto-central negativity (linear increase with syntactic complexity). In addition, the scene could display two actions - unpredictable for the participant, as the disambiguation occurred only later in the animation. Time-locked to the moment of visual disambiguation of the action and thus the verb, we observed another P300 component ('S'>'NP'/'W'). The data show for the first time evidence of sensitivity to syntactic planning within the P300 time window, time-locked to visual events critical of syntactic planning. We discuss the findings in the light of current syntactic planning views.

  12. Test-retest reliability of infant event related potentials evoked by faces.

    Science.gov (United States)

    Munsters, N M; van Ravenswaaij, H; van den Boomen, C; Kemner, C

    2017-04-05

    Reliable measures are required to draw meaningful conclusions regarding developmental changes in longitudinal studies. Little is known, however, about the test-retest reliability of face-sensitive event related potentials (ERPs), a frequently used neural measure in infants. The aim of the current study is to investigate the test-retest reliability of ERPs typically evoked by faces in 9-10 month-old infants. The infants (N=31) were presented with neutral, fearful and happy faces that contained only the lower or higher spatial frequency information. They were tested twice within two weeks. The present results show that the test-retest reliability of the face-sensitive ERP components is moderate (P400 and Nc) to substantial (N290). However, there is low test-retest reliability for the effects of the specific experimental manipulations (i.e. emotion and spatial frequency) on the face-sensitive ERPs. To conclude, in infants the face-sensitive ERP components (i.e. N290, P400 and Nc) show adequate test-retest reliability, but not the effects of emotion and spatial frequency on these ERP components. We propose that further research focuses on investigating elements that might increase the test-retest reliability, as adequate test-retest reliability is necessary to draw meaningful conclusions on individual developmental trajectories of the face-sensitive ERPs in infants. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. Event-related potentials during word mapping to object shape predict toddlers' vocabulary size

    Science.gov (United States)

    Borgström, Kristina; Torkildsen, Janne von Koss; Lindgren, Magnus

    2015-01-01

    What role does attention to different object properties play in early vocabulary development? This longitudinal study using event-related potentials in combination with behavioral measures investigated 20- and 24-month-olds' (n = 38; n = 34; overlapping n = 24) ability to use object shape and object part information in word-object mapping. The N400 component was used to measure semantic priming by images containing shape or detail information. At 20 months, the N400 to words primed by object shape varied in topography and amplitude depending on vocabulary size, and these differences predicted productive vocabulary size at 24 months. At 24 months, when most of the children had vocabularies of several hundred words, the relation between vocabulary size and the N400 effect in a shape context was weaker. Detached object parts did not function as word primes regardless of age or vocabulary size, although the part-objects were identified behaviorally. The behavioral measure, however, also showed relatively poor recognition of the part-objects compared to the shape-objects. These three findings provide new support for the link between shape recognition and early vocabulary development. PMID:25762957

  14. Use of event-related brain potentials (ERPs) to assess eyewitness accuracy and deception.

    Science.gov (United States)

    Lefebvre, C D; Marchand, Y; Smith, S M; Connolly, J F

    2009-09-01

    This study investigated eyewitness identification using ERPs. Twenty participants completed two eyewitness lineup tasks (standard and deception conditions). For the standard condition, participants tried to accurately identify the culprit, whereas in the deception condition, they were asked to deceptively conceal their recognition of the culprit. Identification rates based on P300 patterns were calculated using two different individual analysis procedures (A and B) that varied in stringency. Correct identification rates for the standard condition were 100% for both procedures A and B. For the deception condition, correct identification rates of the concealed culprit were 90%, and 70% respectively for procedures A and B. Data from a prior study [the culprit-absent condition from Lefebvre, C.D., Marchand, Y., Smith, S.M. & Connolly, J.F., 2007. Determining eyewitness identification accuracy using event-related brain potentials (ERPs). Psychophysiology, 44, 894-904.] was reanalysed to investigate differences in false identification rates based on procedures A and B. False identifications were substantially higher when using procedure A (29%) versus procedure B (0%). Overall, superiority was found for procedure B compared to procedure A based on Grier's A'.

  15. How culture gets embrained: Cultural differences in event-related potentials of social norm violations.

    Science.gov (United States)

    Mu, Yan; Kitayama, Shinobu; Han, Shihui; Gelfand, Michele J

    2015-12-15

    Humans are unique among all species in their ability to develop and enforce social norms, but there is wide variation in the strength of social norms across human societies. Despite this fundamental aspect of human nature, there has been surprisingly little research on how social norm violations are detected at the neurobiological level. Building on the emerging field of cultural neuroscience, we combine noninvasive electroencephalography (EEG) with a new social norm violation paradigm to examine the neural mechanisms underlying the detection of norm violations and how they vary across cultures. EEG recordings from Chinese and US participants (n = 50) showed consistent negative deflection of event-related potential around 400 ms (N400) over the central and parietal regions that served as a culture-general neural marker of detecting norm violations. The N400 at the frontal and temporal regions, however, was only observed among Chinese but not US participants, illustrating culture-specific neural substrates of the detection of norm violations. Further, the frontal N400 predicted a variety of behavioral and attitudinal measurements related to the strength of social norms that have been found at the national and state levels, including higher culture superiority and self-control but lower creativity. There were no cultural differences in the N400 induced by semantic violation, suggesting a unique cultural influence on social norm violation detection. In all, these findings provided the first evidence, to our knowledge, for the neurobiological foundations of social norm violation detection and its variation across cultures.

  16. Sex differences in humor processing: An event-related potential study.

    Science.gov (United States)

    Chang, Yi-Tzu; Ku, Li-Chuan; Chen, Hsueh-Chih

    2018-02-01

    Numerous behavioral studies and a handful of functional neuroimaging studies have reported sex differences in humor. However, no study to date has examined differences in the time-course of brain activity during multistage humor processing between the sexes. The purpose of this study was to compare real-time dynamics related to humor processing between women and men, with reference to a proposed three-stage model (involving incongruity detection, incongruity resolution, and elaboration stages). Forty undergraduate students (20 women) underwent event-related potential recording while subjectively rating 30 question-answer-type jokes and 30 question-answer-type statements in a random order. Sex differences were revealed by analyses of the mean amplitudes of difference waves during a specific time window between 1000 and 1300 ms poststimulus onset (P1000-1300). This indicates that women recruited more mental resources to integrate cognitive and emotional components at this late stage. In contrast, men recruited more automated processes during the transition from the cognitive operations of the incongruity resolution stage to the emotional response of the humor elaboration stage. Our results suggest that sex differences in humor processing lie in differences in the integration of cognitive and emotional components, which are closely linked and interact reciprocally, particularly in women. Copyright © 2017 Elsevier Inc. All rights reserved.

  17. Antiherding in Financial Decision Increases Valuation of Return on Investment: An Event-Related Potential Study

    Directory of Open Access Journals (Sweden)

    Cuicui Wang

    2017-01-01

    Full Text Available Using event-related potentials, this study investigated how financial herding or antiherding affected the valuation of subsequent outcomes. For each trial, subjects decided whether to buy the stock according to its net money flow information which could be used to reflect the strength of buying power or selling power of the stock. The return on investment (ROI as feedback included the increase or decrease percentage after subjects’ responses. Results showed that, compared with herding, antiherding induced larger discrepancies of FRN and P300 amplitude between positive ROI and negative ROI, indicating that individuals under antiherding condition had stronger motivation and paid more attention in the evaluation process of ROI. Moreover, only for positive ROI, the amplitudes of FRN and P300 were modulated by two kinds of behaviors. We suggested that individuals making antiherd decisions were more confident with their own ability and choices, which reduced the positive outcome prediction error and gave more mental resources to evaluate positive outcome. However, negative outcomes evoked no different motivational meaning and negative emotion for individuals between herding and antiherding. The study may provide new insights into neurocognitive processes of herding and antiherding in financial market.

  18. ERPLAB: An Open-Source Toolbox for the Analysis of Event-Related Potentials

    Directory of Open Access Journals (Sweden)

    Javier eLopez-Calderon

    2014-04-01

    Full Text Available ERPLAB Toolbox is a freely available, open-source toolbox for processing and analyzing event-related potential (ERP data in the MATLAB environment. ERPLAB is closely integrated with EEGLAB, a popular open-source toolbox that provides many EEG preprocessing steps and an excellent user interface design. ERPLAB adds to EEGLAB’s EEG processing functions, providing additional tools for filtering, artifact detection, re-referencing, and sorting of events, among others. ERPLAB also provides robust tools for averaging EEG segments together to create averaged ERPs, for creating difference waves and other recombinations of ERP waveforms through algebraic expressions, for filtering and re-referencing the averaged ERPs, for plotting ERP waveforms and scalp maps, and for quantifying several types of amplitudes and latencies. ERPLAB’s tools can be accessed either from an easy-to-learn graphical user interface or from MATLAB scripts, and a command history function makes it easy for users with no programming experience to write scripts. Consequently, ERPLAB provides both ease of use and virtually unlimited power and flexibility, making it appropriate for the analysis of both simple and complex ERP experiments. Several forms of documentation are available, including a detailed user’s guide, a step-by-step tutorial, a scripting guide, and a set of video-based demonstrations.

  19. Auditory processing following infantile spasms: An event-related potential study.

    Science.gov (United States)

    Fosi, Tangunu; Werner, Klaus; Boyd, Stewart G; De Haan, Michelle; Scott, Rod C; Neville, Brian G

    2017-05-01

    To investigate acoustic auditory processing in patients with recent infantile spasms (IS). Patients (n = 22; 12 female; median age 8 months; range 5-11 months) had normal preceding development, brain magnetic resonance imaging (MRI), and neurometabolic testing (West syndrome of unknown cause, uWS). Controls were healthy babies (n = 22; 11 female; median age 6 months; range 3-12 months). Event-related potentials (ERPs) and psychometry (Bayley Scales of Infant Development, Second Edition, BSID-II) took place at a month following IS remission. Following a repeated pure tone, uWS patients showed less suppression of the N100 at the mid-temporal electrodes (p = 0.006), and a prolonged response latency (p = 0.019). Their novelty P300 amplitude over the mid-temporal electrodes was halved (p = 0.001). The peak of the novelty P300 to environmental broadband sounds emerged later over the left temporal lobe in patients (p = 0.015), the lag correlating with duration of spasms (r = 0.547, p = 0.015). BSID-II scores were lower in patients (p < 0.001), with no correlation to ERP. Complex acoustic information is processed poorly following IS. This would impair language. Treatment did not reverse this phenomenon, but may have limited its severity. The data are most consistent with altered connectivity of the cortical acoustic processing areas induced by IS. Wiley Periodicals, Inc. © 2017 International League Against Epilepsy.

  20. Change detection in children with autism: an auditory event-related fMRI study.

    Science.gov (United States)

    Gomot, Marie; Bernard, Frédéric A; Davis, Matthew H; Belmonte, Matthew K; Ashwin, Chris; Bullmore, Edward T; Baron-Cohen, Simon

    2006-01-15

    Autism involves impairments in communication and social interaction, as well as high levels of repetitive, stereotypic, and ritualistic behaviours, and extreme resistance to change. This latter dimension, whilst required for a diagnosis, has received less research attention. We hypothesise that this extreme resistance to change in autism is rooted in atypical processing of unexpected stimuli. We tested this using auditory event-related fMRI to determine regional brain activity associated with passive detection of infrequently occurring frequency-deviant and complex novel sounds in a no-task condition. Participants were twelve 10- to 15-year-old children with autism and a group of 12 age- and sex-matched healthy controls. During deviance detection, significant activation common to both groups was located in the superior temporal and inferior frontal gyri. During 'novelty detection', both groups showed activity in the superior temporal gyrus, the temporo-parietal junction, the superior and inferior frontal gyri, and the cingulate gyrus. Children with autism showed reduced activation of the left anterior cingulate cortex during both deviance and novelty detection. During novelty detection, children with autism also showed reduced activation in the bilateral temporo-parietal region and in the right inferior and middle frontal areas. This study confirms previous evidence from ERP studies of atypical brain function related to automatic change detection in autism. Abnormalities involved a cortical network known to have a role in attention switching and attentional resource distribution. These results throw light on the neurophysiological processes underlying autistic 'resistance to change'.

  1. Antiherding in Financial Decision Increases Valuation of Return on Investment: An Event-Related Potential Study.

    Science.gov (United States)

    Wang, Cuicui; Jin, Jia; Vieito, João Paulo; Ma, Qingguo

    2017-01-01

    Using event-related potentials, this study investigated how financial herding or antiherding affected the valuation of subsequent outcomes. For each trial, subjects decided whether to buy the stock according to its net money flow information which could be used to reflect the strength of buying power or selling power of the stock. The return on investment (ROI) as feedback included the increase or decrease percentage after subjects' responses. Results showed that, compared with herding, antiherding induced larger discrepancies of FRN and P300 amplitude between positive ROI and negative ROI, indicating that individuals under antiherding condition had stronger motivation and paid more attention in the evaluation process of ROI. Moreover, only for positive ROI, the amplitudes of FRN and P300 were modulated by two kinds of behaviors. We suggested that individuals making antiherd decisions were more confident with their own ability and choices, which reduced the positive outcome prediction error and gave more mental resources to evaluate positive outcome. However, negative outcomes evoked no different motivational meaning and negative emotion for individuals between herding and antiherding. The study may provide new insights into neurocognitive processes of herding and antiherding in financial market.

  2. Neural correlates of belief-laden reasoning during premise processing: an event-related potential study.

    Science.gov (United States)

    Luo, Junlong; Yang, Qun; Du, Xiumin; Zhang, Qinglin

    2011-01-01

    In this study, electrophysiological correlates of belief-laden reasoning were investigated. As subjects, trained participants were required to draw a logical conclusion after being exposed to 4 conditional arguments: the inhibitory content of modus tollens (ICMT), facilitatory content of modus tollens (FCMT), inhibitory content of denial of the antecedent (ICDA) and facilitatory content of denial of the antecedent (FCDA). Event-related potentials were employed to record the processing of minor premises. The results show that in comparison with FCMT, a greater negativity in the ICMT developed during both the 400- to 600- and the 800- to 1,600-ms time windows. A greater anterior cingulate cortex activity observed in the 800- to 1,600-ms time window in ICMT could reflect a detection of the conflict between empirical beliefs and logical rules. However, the components elicited by ICDA and FCDA were not significantly different. The results indicate that logical training influenced MT and DA forms of belief-laden reasoning in different ways and different strategies were likely adopted in the inference processes. © 2010 S. Karger AG, Basel.

  3. Event-related potentials reveal early activation of syntax information in Chinese verb processing.

    Science.gov (United States)

    Deng, Yuan; Wu, Qiuyan; Wang, Jin; Feng, Liping; Xiao, Qing

    2016-09-19

    By taking advantage of the semantic-syntactic characteristics of Chinese verbs, the current study examined the brain activity of automatic activation of syntactic features at the single word level. Both syntactic (transitivity) and semantic (integrity) features of the verb were manipulated. Event-related potentials were measured while subjects performed lexical decision tasks on visually presented verbs at the single word level. The results showed that there was a significant transitivity effect in both lateral and midline areas for the 150-200ms time window (N200 effect), indicating the retrieval of the syntactic feature. There was also a significant syntactic-semantic interaction at the late stage of verb processing (N400 effect) in the midline central-parietal region, reflecting syntactic influences on semantic processing. These findings suggest that transitivity is an integral part of the mental representation of Chinese verbs and such information can be retrieved at the early stage of single verb processing and can influence subsequent semantic integration. These results also reveal the special features of Chinese language processing. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  4. Priming prepositional phrase attachment: evidence from eye-tracking and event-related potentials.

    Science.gov (United States)

    Boudewyn, Megan A; Zirnstein, Megan; Swaab, Tamara Y; Traxler, Matthew J

    2014-01-01

    Three syntactic-priming experiments investigated the effect of structurally similar or dissimilar prime sentences on the processing of target sentences, using eye tracking (Experiment 1) and event-related potentials (ERPs) (Experiments 2 and 3) All three experiments tested readers' response to sentences containing a temporary syntactic ambiguity. The ambiguity occurred because a prepositional phrase modifier (PP-modifier) could attach either to a preceding verb or to a preceding noun. Previous experiments have established that (a) noun-modifying expressions are harder to process than verb-modifying expressions (when test sentences are presented in isolation); and (b) for other kinds of sentences, processing a structurally similar prime sentence can facilitate processing a target sentence. The experiments reported here were designed to determine whether a structurally similar prime could facilitate processing of noun-attached modifiers and whether such facilitation reflected syntactic-structure-building or semantic processes. These findings have implications for accounts of structural priming during online comprehension and for accounts of syntactic representation and processing in comprehension.

  5. Event-related potentials in response to violations of content and temporal event knowledge.

    Science.gov (United States)

    Drummer, Janna; van der Meer, Elke; Schaadt, Gesa

    2016-01-08

    Scripts that store knowledge of everyday events are fundamentally important for managing daily routines. Content event knowledge (i.e., knowledge about which events belong to a script) and temporal event knowledge (i.e., knowledge about the chronological order of events in a script) constitute qualitatively different forms of knowledge. However, there is limited information about each distinct process and the time course involved in accessing content and temporal event knowledge. Therefore, we analyzed event-related potentials (ERPs) in response to either correctly presented event sequences or event sequences that contained a content or temporal error. We found an N400, which was followed by a posteriorly distributed P600 in response to content errors in event sequences. By contrast, we did not find an N400 but an anteriorly distributed P600 in response to temporal errors in event sequences. Thus, the N400 seems to be elicited as a response to a general mismatch between an event and the established event model. We assume that the expectancy violation of content event knowledge, as indicated by the N400, induces the collapse of the established event model, a process indicated by the posterior P600. The expectancy violation of temporal event knowledge is assumed to induce an attempt to reorganize the event model in working memory, a process indicated by the frontal P600. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. High-resolution three-dimensional diffusion-weighted imaging of middle ear cholesteatoma at 3.0 T MRI: Usefulness of 3D turbo field-echo with diffusion-sensitized driven-equilibrium preparation (TFE–DSDE) compared to single-shot echo-planar imaging

    International Nuclear Information System (INIS)

    Yamashita, Koji; Yoshiura, Takashi; Hiwatashi, Akio; Obara, Makoto; Togao, Osamu; Matsumoto, Nozomu; Kikuchi, Kazufumi; Honda, Hiroshi

    2013-01-01

    Objective: To prospectively evaluate the usefulness of a newly developed high-resolution three-dimensional diffusion-weighted imaging method, turbo field-echo with diffusion-sensitized driven-equilibrium (TFE–DSDE) in diagnosing middle-ear cholesteatoma by comparing it to conventional single-shot echo-planar diffusion-weighted imaging (SS-EP DWI). Materials and methods: Institutional review board approval and informed consent from all participants were obtained. We studied 30 patients with preoperatively suspected acquired cholesteatoma. Each patient underwent an MR examination including both SS-EP DWI and DSDE-TFE using a 3.0 T MR scanner. Images of the 30 patients (60 temporal bones including 30 with and 30 without cholesteatoma) were reviewed by two independent neuroradiologists. The confidence level for the presence of cholesteatoma was graded on a scale of 0–2 (0 = definite absence, 1 = equivocal, 2 = definite presence). Interobserver agreement as well as sensitivity, specificity, and accuracy for detection were assessed for the two reviewers. Results: Excellent interobserver agreement was shown for TFE–DSDE (κ = 0.821) whereas fair agreement was obtained for SS-EP DWI (κ = 0.416). TFE–DSDE was associated with significantly higher sensitivity (83.3%) and accuracy (90.0%) compared to SS-EP DWI (sensitivity = 35.0%, accuracy = 66.7%; p < 0.05). No significant difference was found in specificity (96.7% for TFE–DSDE, 98.3% for SS-EP DWI) Conclusion: With increased spatial resolution and reduced susceptibility artifacts, TFE–DSDE improves the accuracy in diagnosing acquired middle ear cholesteatomas compared to SS-EP DWI

  7. Process conditions and volumetric composition in composites

    DEFF Research Database (Denmark)

    Madsen, Bo

    2013-01-01

    The obtainable volumetric composition in composites is linked to the gravimetric composition, and it is influenced by the conditions of the manufacturing process. A model for the volumetric composition is presented, where the volume fractions of fibers, matrix and porosity are calculated...... as a function of the fiber weight fraction, and where parameters are included for the composite microstructure, and the fiber assembly compaction behavior. Based on experimental data of composites manufactured with different process conditions, together with model predictions, different types of process related...... the fiber and matrix volume fractions are only slightly changed. Air entrapment in the matrix due to non-ideal process conditions is found to have a marked effect on the volumetric composition. For composites with such type of matrix porosity, the porosity content is decreased when the fiber content...

  8. Volumetric composition in composites and historical data

    DEFF Research Database (Denmark)

    Lilholt, Hans; Madsen, Bo

    2013-01-01

    The obtainable volumetric composition in composites is of importance for the prediction of mechanical and physical properties, and in particular to assess the best possible (normally the highest) values for these properties. The volumetric model for the composition of (fibrous) composites gives...... guidance to the optimal combination of fibre content, matrix content and porosity content, in order to achieve the best obtainable properties. Several composite materials systems have been shown to be handleable with this model. An extensive series of experimental data for the system of cellulose fibres...... and polymer (resin) was produced in 1942 – 1944, and these data have been (re-)analysed by the volumetric composition model, and the property values for density, stiffness and strength have been evaluated. Good agreement has been obtained and some further observations have been extracted from the analysis....

  9. Relationship between somatosensory event-related potential N140 aberrations and hemispatial agnosia in patients with stroke: a preliminary study.

    Science.gov (United States)

    Ueno, Tomoyuki; Hada, Yasushi; Shimizu, Yukiyo; Yamada, Thoru

    2018-06-01

    The somatosensory event-related potential N140 is thought to be related to selective attention. This study aimed to compare the somatosensory event-related potential N140 in healthy subjects to that in patients with stroke to determine whether N140 and attentiveness are associated in patients with stroke with or without hemispatial agnosia. Normal somatosensory event-related potential N140 values were determined using data from ten healthy subjects. Fifteen patients with stroke were divided into two groups based on the presence of hemispatial neglect. Somatosensory event-related potential N140 components were compared between the two groups. Stimulation of the affected limb in the hemispatial agnosia group resulted in significantly longer N140 latency at the contralateral vs. the ipsilateral electrode. This was the inverse of the relationship observed in normal subjects, with stimulation of the intact side in patients with hemispatial agnosia, and with stimulation of both the intact and affected sides in patients without agnosia. In the hemispatial agnosia group, the peak latency of N140 following stimulation of the affected side was significantly longer than it was following stimulation of the intact side and when compared to that in patients without agnosia. In addition, abnormal N140 peak latencies were observed at the Cz and ipsilateral electrodes in patients with hemispatial agnosia following stimulation of the intact side. These findings suggest that somatosensory event-related potential N140 is independently generated in each hemisphere and may reflect cognitive attention.

  10. Who Are the True Fans? Evidence from an Event-Related Potential Study.

    Directory of Open Access Journals (Sweden)

    Qingguo Ma

    Full Text Available Fans of celebrities commonly exist in modern society. Researchers from social science have been concerned with this problem for years. Furthermore, such researchers have attempted to measure people's involvement with celebrities in various ways. However, no study measured the degree of addiction to a specific celebrity at the neurological level. Therefore, the current study employed visually evoked event related potentials (ERPs to examine people's attitude toward celebrities by comparing different brain activities of fans and non-fans when they were shown a set of photos. These photos include a specific celebrity, a familiar person, a stranger and a butterfly. Furthermore, to examine the validity of the detected neural index, we also investigated the correlation between brain activity and the score of the Celebrity Attitude Scale (CAS, which was a questionnaire used to explore people's attitude toward celebrities at behavioral level. Two groups of subjects were asked to complete an implicit task, i.e., to press a button when a picture of a butterfly appeared. Results revealed that fans showed significant positive N2 and P300 deflection when viewing the photos of their favorite celebrity, whereas in the non-fan group, the subjects only showed larger P300 amplitude as a response to the celebrity's photos. Furthermore, a positive correlation between P300 amplitude elicited by the stimuli of a celebrity face and CAS scores was also observed. These findings indicated fan attitude to a specific celebrity can also be observed at the neurological level and suggested the potential utility of using ERP component as an index of fandom involvement.

  11. Modality-match effect in false recognition: an event-related potential study.

    Science.gov (United States)

    Boldini, Angela; Beato, Maria Soledad; Cadavid, Sara

    2013-02-13

    In the Deese-Roediger-McDermott (DRM) paradigm, participants falsely recall or recognize a nonpresented word (critical lure), highly associated with previously studied words. As numerous DRM studies have found a robust false memory effect at the behavioural level, event-related potentials (ERPs) studies have searched for possible overlapping in brain electrical activity between true and false memory. Using the DRM paradigm, the present experiment manipulated the sensory modality of stimulus presentation (auditory vs. visual) in the study phase to analyse the effect of modality match between study and test on true and false recognition. Words were therefore presented either visually or auditorily at study and always visually at test. True recognition was found to be significantly higher in the modality 'match' condition (visual-visual) than in the 'mismatch' condition (auditory-visual), whereas there was no modality-match effect on false recognition of critical lures. A general, overlapping was found between ERP correlates of true and false recognition: FN400 (300-500 ms), left-parietal (400-800 ms) and late right-frontal (1000-1500 ms) old/new effects were similar for both studied words and critical lures. No sensory modality-match effect was associated with FN400 or left-parietal old/new effects. Only the late right-frontal activity was modulated by modality manipulation, with significantly more positive ERPs in the modality-match condition. Sensory modality match of stimulus presentation, therefore, dissociated true and false recognition memory only at the behavioural level but not at the ERP level. Overall, true and false recognition memories seem to share common underlying processes.

  12. Extending or creating a new brand: evidence from a study on event-related potentials.

    Science.gov (United States)

    Jin, Jia; Wang, Cuicui; Yu, Liping; Ma, Qingguo

    2015-07-08

    Brand strategy is a critical problem in new product promotion. In relation to this, producers typically have two main options, namely, brand extension and new brand creation. The current study investigated the neural basis of evaluating these brand strategies at the brain level by using event-related potentials. The experiment used a word-pair paradigm, in which the first word was either a famous beverage brand name or a newly created brand, and the second word was a product name from one of the two product categories (beverage or household appliance). Therefore, four conditions existed as follows: a famous beverage brand paired with a beverage product (BB) or with a household appliance (BH) and a newly created brand paired with a beverage product (NB) or with a household appliance (NH). Behavioral results showed that brand extension obtained a higher acceptance rate than new brand creation under the beverage product category; however, a lower acceptance rate was observed under the household appliance category. Moreover, at the brain level, BB elicited lower N400 mean amplitude than the new brand product NB, whereas BH led to higher N400 amplitude than the new brand product NH. These results showed that the likelihood of accepting a product depended on the association between the brand name and product name, and that the N400 could serve as an index of brand strategy evaluation. In addition, this study also confirmed that brand extension is not always the best brand strategy; an inappropriate extension sometimes performed worse than the creation of a new brand.

  13. Examining Event-Related Potential (ERP correlates of decision bias in recognition memory judgments.

    Directory of Open Access Journals (Sweden)

    Holger Hill

    Full Text Available Memory judgments can be based on accurate memory information or on decision bias (the tendency to report that an event is part of episodic memory when one is in fact unsure. Event related potentials (ERP correlates are important research tools for elucidating the dynamics underlying memory judgments but so far have been established only for investigations of accurate old/new discrimination. To identify the ERP correlates of bias, and observe how these interact with ERP correlates of memory, we conducted three experiments that manipulated decision bias within participants via instructions during recognition memory tests while their ERPs were recorded. In Experiment 1, the bias manipulation was performed between blocks of trials (automatized bias and compared to trial-by-trial shifts of bias in accord with an external cue (flexibly controlled bias. In Experiment 2, the bias manipulation was performed at two different levels of accurate old/new discrimination as the memory strength of old (studied items was varied. In Experiment 3, the bias manipulation was added to another, bottom-up driven manipulation of bias induced via familiarity. In the first two Experiments, and in the low familiarity condition of Experiment 3, we found evidence of an early frontocentral ERP component at 320 ms poststimulus (the FN320 that was sensitive to the manipulation of bias via instruction, with more negative amplitudes indexing more liberal bias. By contrast, later during the trial (500-700 ms poststimulus, bias effects interacted with old/new effects across all three experiments. Results suggest that the decision criterion is typically activated early during recognition memory trials, and is integrated with retrieved memory signals and task-specific processing demands later during the trial. More generally, the findings demonstrate how ERPs can help to specify the dynamics of recognition memory processes under top-down and bottom-up controlled retrieval conditions.

  14. Multivariate assessment of event-related potentials with the t-CWT method.

    Science.gov (United States)

    Bostanov, Vladimir

    2015-11-05

    Event-related brain potentials (ERPs) are usually assessed with univariate statistical tests although they are essentially multivariate objects. Brain-computer interface applications are a notable exception to this practice, because they are based on multivariate classification of single-trial ERPs. Multivariate ERP assessment can be facilitated by feature extraction methods. One such method is t-CWT, a mathematical-statistical algorithm based on the continuous wavelet transform (CWT) and Student's t-test. This article begins with a geometric primer on some basic concepts of multivariate statistics as applied to ERP assessment in general and to the t-CWT method in particular. Further, it presents for the first time a detailed, step-by-step, formal mathematical description of the t-CWT algorithm. A new multivariate outlier rejection procedure based on principal component analysis in the frequency domain is presented as an important pre-processing step. The MATLAB and GNU Octave implementation of t-CWT is also made publicly available for the first time as free and open source code. The method is demonstrated on some example ERP data obtained in a passive oddball paradigm. Finally, some conceptually novel applications of the multivariate approach in general and of the t-CWT method in particular are suggested and discussed. Hopefully, the publication of both the t-CWT source code and its underlying mathematical algorithm along with a didactic geometric introduction to some basic concepts of multivariate statistics would make t-CWT more accessible to both users and developers in the field of neuroscience research.

  15. How Social Ties Influence Consumer: Evidence from Event-Related Potentials.

    Directory of Open Access Journals (Sweden)

    Jing Luan

    Full Text Available A considerable amount of marketing research has reported that consumers are more saliently influenced by friends (strong social ties than by acquaintances and strangers (weak social ties. To shed light on the neural and psychological processes underlying such phenomenon, in this study we designed an amended S1-S2 paradigm (product-[reviewer-review] that is based on realistic consumer purchase experiences. After incoming all given information (product, reviewer, review, participants were required to state their purchase intentions. The neurocognitive and emotional processes related to friend and stranger stimuli were delineated to suggest how social ties influence consumers during their shopping processes. Larger P2 (fronto-central scalp areas and P3 (central and posterior-parietal scalp areas components under stranger condition were elicited successfully. These findings demonstrate that the cognitive and emotional processing of friend and stranger stimuli occurs at stages of neural activity, and can be indicated by the P2 and P3 components. Electrophysiological data also support the hypothesis that different neural and emotional processing magnitude and strength underlie friend and stranger effect in the context of consumer purchase. During this process, the perception of stimuli evoked P2, subsequently emotional processing and attention modulation were activated and indicated by P2 and P3. The friend dominated phenomenon can be interpreted as the result of distinctive neurocognitive and emotional processing magnitude, which suggests that psychological and emotional factors can guide consumer decision making. This study consolidates that event related potential (ERP methodology is likely to be a more sensitive method for investigating consumer behaviors. From the perspectives of management and marketing, our findings show that the P2 and P3 components can be employed as an indicator to probe the influential factors of consumer purchase

  16. An exploratory event-related potential study of multisensory integration in sensory over-responsive children.

    Science.gov (United States)

    Brett-Green, Barbara A; Miller, Lucy J; Schoen, Sarah A; Nielsen, Darci M

    2010-03-19

    Children who are over-responsive to sensation have defensive and "fight or flight" reactions to ordinary levels of sensory stimulation in the environment. Based on clinical observations, sensory over-responsivity is hypothesized to reflect atypical neural integration of sensory input. To examine a possible underlying neural mechanism of the disorder, integration of simultaneous multisensory auditory and somatosensory stimulation was studied in twenty children with sensory over-responsivity (SOR) using event-related potentials (ERPs). Three types of sensory stimuli were presented and ERPs were recorded from thirty-two scalp electrodes while participants watched a silent cartoon: bilateral auditory clicks, right somatosensory median nerve electrical pulses, or both simultaneously. The paradigm was passive; no behavioral responses were required. To examine integration, responses to simultaneous multisensory auditory-somatosensory stimulation were compared to the sum of unisensory auditory plus unisensory somatosensory responses in four time-windows: (60-80 ms, 80-110 ms, 110-150 ms, and 180-220 ms). Specific midline and lateral electrode sites were examined over scalp regions where auditory-somatosensory integration was expected based on previous studies. Midline electrode sites (Fz, Cz, and Pz) showed significant integration during two time-windows: 60-80 ms and 180-220 ms. Significant integration was also found at contralateral electrode site (C3) for the time-window between 180 and 220 ms. At ipsilateral electrode sites (C4 and CP6), no significant integration was found during any of the time-windows (i.e. the multisensory ERP was not significantly different from the summed unisensory ERP). These results demonstrate that MSI can be reliably measured in children with SOR and provide evidence that multisensory auditory-somatosensory input is integrated during both early and later stages of sensory information processing, mainly over fronto-central scalp regions. 2010

  17. Auditory stream segregation using bandpass noises: evidence from event-related potentials

    Directory of Open Access Journals (Sweden)

    Yingjiu eNie

    2014-09-01

    Full Text Available The current study measured neural responses to investigate auditory stream segregation of noise stimuli with or without clear spectral contrast. Sequences of alternating A and B noise bursts were presented to elicit stream segregation in normal-hearing listeners. The successive B bursts in each sequence maintained an equal amount of temporal separation with manipulations introduced on the last stimulus. The last B burst was either delayed for 50% of the sequences or not delayed for the other 50%. The A bursts were jittered in between every two adjacent B bursts. To study the effects of spectral separation on streaming, the A and B bursts were further manipulated by using either bandpass-filtered noises widely spaced in center frequency or broadband noises. Event-related potentials (ERPs to the last B bursts were analyzed to compare the neural responses to the delay vs. no-delay trials in both passive and attentive listening conditions. In the passive listening condition, a trend for a possible late mismatch negativity (MMN or late discriminative negativity (LDN response was observed only when the A and B bursts were spectrally separate, suggesting that spectral separation in the A and B burst sequences could be conducive to stream segregation at the pre-attentive level. In the attentive condition, a P300 response was consistently elicited regardless of whether there was spectral separation between the A and B bursts, indicating the facilitative role of voluntary attention in stream segregation. The results suggest that reliable ERP measures can be used as indirect indicators for auditory stream segregation in conditions of weak spectral contrast. These findings have important implications for cochlear implant (CI studies – as spectral information available through a CI device or simulation is substantially degraded, it may require more attention to achieve stream segregation.

  18. Cognitive deficits following exposure to pneumococcal meningitis: an event-related potential study

    Directory of Open Access Journals (Sweden)

    Kihara Michael

    2012-03-01

    Full Text Available Abstract Background Pneumococcal meningitis (PM is a severe and life-threatening disease that is associated with cognitive impairment including learning difficulties, cognitive slowness, short-term memory deficits and poor academic performance. There are limited data on cognitive outcomes following exposure to PM from Africa mainly due to lack of culturally appropriate tools. We report cognitive processes of exposed children as measured by auditory and visual event-related potentials. Methods Sixty-five children (32 male, mean 8.4 years, SD 3.0 years aged between 4-15 years with a history of PM and an age-matched control group of 93 children (46 male; mean 8.4 years, SD 2.7 years were recruited from a well-demarcated study area in Kilifi. In the present study, both baseline to peak and peak-to-peak amplitude differences are reported. Results Children with a history of pneumococcal meningitis had significantly longer auditory P1 and P3a latencies and smaller P1 amplitudes compared to unexposed children. In the visual paradigm, children with PM seemingly lacked a novelty P3a component around 350 ms where control children had a maximum, and showed a lack of stimulus differentiation at Nc. Further, children with exposure to PM had smaller peak to peak amplitude (N2-P1 compared to unexposed children. Conclusion The results suggest that children with a history of PM process novelty differently than do unexposed children, with slower latencies and reduced or absent components. This pattern suggests poorer auditory attention and/or cognitive slowness and poorer visual attention orienting, possibly due to disruption in the functions of the lateral prefrontal and superior temporal cortices. ERPs may be useful for assessment of the development of perceptual-cognitive functions in post brain-injury in African children by providing an alternate way of assessing cognitive development in patient groups for whom more typical standardized neuropsychological

  19. Recognition Memory in Amnestic-Mild Cognitive Impairment: Insights from Event-Related Potentials

    Directory of Open Access Journals (Sweden)

    David A Wolk

    2013-12-01

    Full Text Available Episodic memory loss is the hallmark cognitive dysfunction associated with Alzheimer’s Disease (AD. Amnestic Mild Cognitive Impairment (a-MCI frequently represents a transitional stage between normal aging and early AD. A better understanding of the qualitative features of memory loss in a-MCI may have important implications for predicting those most likely to harbor AD-related pathology and for disease monitoring. Dual process models of memory argue that recognition memory is subserved by the dissociable processes of recollection and familiarity. Work studying recognition memory in a-MCI from this perspective has been controversial, particularly with regard to the integrity of familiarity. Event-related potentials (ERPs offer an alternative means for assessing these functions without the associated assumptions of behavioral estimation methods. ERPs were recorded while a-MCI patients and cognitively normal (CN age-matched adults performed a recognition memory task. When retrieval success was measured (hits versus correct rejections in which performance was matched by group, a-MCI patients displayed similar neural correlates to that of the CN group, including modulation of the FN400 and the late parietal complex (LPC which are thought to index familiarity and recollection, respectively. Alternatively, when the integrity of these components were measured based on retrieval attempts (studied versus unstudied items, a-MCI patients displayed a reduced FN400 and LPC. Furthermore, modulation of the FN400 correlated with a behavioral estimate of familiarity and the LPC with a behavioral estimates of recollection obtained in a separate experiment in the same individuals, consistent with the proposed mappings of these indices. These results support a global decline of recognition memory in a-MCI, which suggests that the memory loss of prodromal AD may be qualitatively distinct from normal aging.

  20. How Social Ties Influence Consumer: Evidence from Event-Related Potentials.

    Science.gov (United States)

    Luan, Jing; Yao, Zhong; Bai, Yan

    2017-01-01

    A considerable amount of marketing research has reported that consumers are more saliently influenced by friends (strong social ties) than by acquaintances and strangers (weak social ties). To shed light on the neural and psychological processes underlying such phenomenon, in this study we designed an amended S1-S2 paradigm (product-[reviewer-review]) that is based on realistic consumer purchase experiences. After incoming all given information (product, reviewer, review), participants were required to state their purchase intentions. The neurocognitive and emotional processes related to friend and stranger stimuli were delineated to suggest how social ties influence consumers during their shopping processes. Larger P2 (fronto-central scalp areas) and P3 (central and posterior-parietal scalp areas) components under stranger condition were elicited successfully. These findings demonstrate that the cognitive and emotional processing of friend and stranger stimuli occurs at stages of neural activity, and can be indicated by the P2 and P3 components. Electrophysiological data also support the hypothesis that different neural and emotional processing magnitude and strength underlie friend and stranger effect in the context of consumer purchase. During this process, the perception of stimuli evoked P2, subsequently emotional processing and attention modulation were activated and indicated by P2 and P3. The friend dominated phenomenon can be interpreted as the result of distinctive neurocognitive and emotional processing magnitude, which suggests that psychological and emotional factors can guide consumer decision making. This study consolidates that event related potential (ERP) methodology is likely to be a more sensitive method for investigating consumer behaviors. From the perspectives of management and marketing, our findings show that the P2 and P3 components can be employed as an indicator to probe the influential factors of consumer purchase intentions.

  1. Distinct modulation of event-related potentials during motor preparation in patients with motor conversion disorder.

    Directory of Open Access Journals (Sweden)

    Rebekah L Blakemore

    Full Text Available OBJECTIVE: Conversion paresis patients and healthy people feigning weakness both exhibit weak voluntary movement without detectable neuropathology. Uniquely, conversion patients lack a sense of conscious awareness of the origin of their impairment. We investigated whether conversion paresis patients show distinct electroencephalographic (EEG markers associated with their unconscious movement deficits. METHODS: Six unilateral upper limb conversion paresis patients, 12 feigning participants asked to mimic weakness and 12 control participants performed a precued reaction time task, requiring movements of either hand, depending on precue information. Performance measures (force, reaction and movement time, and event-related EEG potentials (ERP were compared, between groups and across hands or hemisphere, using linear mixed models. RESULTS: Feigners generated the same inter-hand difference in reaction and movement time as expressed by patients, even though no specific targets were set nor feedback given on these measures. We found novel ERP signatures specific to patients. When the symptomatic hand was precued, the P3 ERP component accompanying the precue was dramatically larger in patients than in feigning participants. Additionally, in patients the earlier N1 ERP component was diminished when the precue signalled either the symptomatic or asymptomatic hand. CONCLUSIONS: These results are consistent with previous suggestions that lack of awareness of the origin of their symptoms in conversion disorder patients may result from suppression of brain activity normally related to self-agency. In patients the diminished N1 to all precues is consistent with a generalised reduction in cognitive processing of movement-related precues. The P3 enhancement in patients is unlikely to simply reflect changes required for generation of impaired movements, because it was not seen in feigners showing the same behavioural deficits. Rather, this P3 enhancement in

  2. Event-Related Potential Responses to Task Switching Are Sensitive to Choice of Spatial Filter

    Directory of Open Access Journals (Sweden)

    Aaron S. W. Wong

    2018-03-01

    Full Text Available Event-related potential (ERP studies using the task-switching paradigm show that multiple ERP components are modulated by activation of proactive control processes involved in preparing to repeat or switch task and reactive control processes involved in implementation of the current or new task. Our understanding of the functional significance of these ERP components has been hampered by variability in their robustness, as well as their temporal and scalp distribution across studies. The aim of this study is to examine the effect of choice of reference electrode or spatial filter on the number, timing and scalp distribution of ERP elicited during task-switching. We compared four configurations, including the two most common (i.e., average mastoid reference and common average reference and two novel ones that aim to reduce volume conduction (i.e., reference electrode standardization technique (REST and surface Laplacian on mixing cost and switch cost effects in cue-locked and target-locked ERP waveforms in 201 healthy participants. All four spatial filters showed the same well-characterized ERP components that are typically seen in task-switching paradigms: the cue-locked switch positivity and target-locked N2/P3 effect. However, both the number of ERP effects associated with mixing and switch cost, and their temporal and spatial resolution were greater with the surface Laplacian transformation which revealed rapid temporal adjustments that were not identifiable with other spatial filters. We conclude that the surface Laplacian transformation may be more suited to characterize EEG signatures of complex spatiotemporal networks involved in cognitive control.

  3. Development of event related negativity together with an internal model of audio-motor associations

    Directory of Open Access Journals (Sweden)

    Kai eLutz

    2013-09-01

    Full Text Available The brain’s reactions to error are manifested in several event related potentials (ERP components, derived from electroencephalographic (EEG signals. Although these components have been known for decades, their interpretation is still controversial. A current hypothesis (first indicator hypothesis claims that the first indication of an action being erroneous leads to a negative deflection of the EEG signal over frontal midline areas. In some cases this requires sensory feedback in the form of knowledge of results (KR. If KR is given, then the first negative deflection can be found around 250 ms after feedback presentation (feedback related negativity, FRN. When KR is not required, a negative deflection is found already around 100 ms after action onset (ERN. This deflection may be evoked when a mismatch between required and actually executed actions is detected. To detect such a mismatch, however, necessitates knowledge about which action is required. To test this assumption, the current study monitored EEG error components during acquisition of an internal model, i.e., acquisition of the knowledge of which actions are needed to reach certain goals. Actions consisted of finger presses on a piano keyboard and goals were tones of a certain pitch to be generated, thus the internal model represented audio-motor mapping. Results show that with increasing proficiency in mapping goals to appropriate actions, the amplitude of the ERN increased, whereas the amplitude of the FRN remained unchanged. Thus, when knowledge is present about which action is required, this supports generation of an ERN around 100ms, likely by detecting a mismatch between required and performed actions. This is in accordance with the first indicator hypothesis. The present study furthermore lends support to the notion that FRN mainly relies on comparison of sensory targets with sensory feedback.

  4. Who Are the True Fans? Evidence from an Event-Related Potential Study.

    Science.gov (United States)

    Ma, Qingguo; Jin, Jia; Yuan, Ruixian; Zhang, Wuke

    2015-01-01

    Fans of celebrities commonly exist in modern society. Researchers from social science have been concerned with this problem for years. Furthermore, such researchers have attempted to measure people's involvement with celebrities in various ways. However, no study measured the degree of addiction to a specific celebrity at the neurological level. Therefore, the current study employed visually evoked event related potentials (ERPs) to examine people's attitude toward celebrities by comparing different brain activities of fans and non-fans when they were shown a set of photos. These photos include a specific celebrity, a familiar person, a stranger and a butterfly. Furthermore, to examine the validity of the detected neural index, we also investigated the correlation between brain activity and the score of the Celebrity Attitude Scale (CAS), which was a questionnaire used to explore people's attitude toward celebrities at behavioral level. Two groups of subjects were asked to complete an implicit task, i.e., to press a button when a picture of a butterfly appeared. Results revealed that fans showed significant positive N2 and P300 deflection when viewing the photos of their favorite celebrity, whereas in the non-fan group, the subjects only showed larger P300 amplitude as a response to the celebrity's photos. Furthermore, a positive correlation between P300 amplitude elicited by the stimuli of a celebrity face and CAS scores was also observed. These findings indicated fan attitude to a specific celebrity can also be observed at the neurological level and suggested the potential utility of using ERP component as an index of fandom involvement.

  5. Multivariate evaluation of brain function by measuring regional cerebral blood flow and event-related potentials

    International Nuclear Information System (INIS)

    Koga, Yoshihiko; Mochida, Masahiko; Shutara, Yoshikazu; Nakagawa, Kazumi; Nagata, Ken

    1998-01-01

    To measure the effect of events on human cognitive function, effects of odors by measurement regional cerebral blood flow (rCBF) and P300 were evaluated during the auditory odd-ball exercise. PET showed the increase in rCBF on the right hemisphere of the brain by coffee aroma. rCBF was measured by PET in 9 of right-handed healthy adults men, and P300 was by event-related potential (ERP) in each sex of 20 right-handed healthy adults. ERP showed the difference of the P300 amplitude between men and women, and showed the tendency, by odors except the lavender oil, that women had higher in the P300 amplitude than men. These results suggest the presence of effects on the cognitive function through emotional actions. Next, the relationship between rCBF and ERP were evaluated. The subjects were 9 of the right-handed healthy adults (average: 25.6±3.4 years old). rCBF by PET and P300 amplitude by ERP were simultaneously recorded during the auditory odd-ball exercise using the tone-burst method (2 kHz of the low frequency aimed stimuli and 1 kHz of the high frequency non-aimed stimuli). The rCBF value was the highest at the transverse gyrus of Heschl and the lowest at the piriform cortex among 24 regions of interest (ROI) from both sides. The difference of P300 peak latent time among ROI was almost the same. The brain waves from Cz and Pz were similar and the average amplitude was highest at Pz. We found the high correlation in the right piriform cortex (Fz), and right (Fz, Cz) and left (Cz, Pz) transverse gyrus of Heschl between the P300 amplitude and rCBF. (K.H.)

  6. Examining Event-Related Potential (ERP) Correlates of Decision Bias in Recognition Memory Judgments

    Science.gov (United States)

    Hill, Holger; Windmann, Sabine

    2014-01-01

    Memory judgments can be based on accurate memory information or on decision bias (the tendency to report that an event is part of episodic memory when one is in fact unsure). Event related potentials (ERP) correlates are important research tools for elucidating the dynamics underlying memory judgments but so far have been established only for investigations of accurate old/new discrimination. To identify the ERP correlates of bias, and observe how these interact with ERP correlates of memory, we conducted three experiments that manipulated decision bias within participants via instructions during recognition memory tests while their ERPs were recorded. In Experiment 1, the bias manipulation was performed between blocks of trials (automatized bias) and compared to trial-by-trial shifts of bias in accord with an external cue (flexibly controlled bias). In Experiment 2, the bias manipulation was performed at two different levels of accurate old/new discrimination as the memory strength of old (studied) items was varied. In Experiment 3, the bias manipulation was added to another, bottom-up driven manipulation of bias induced via familiarity. In the first two Experiments, and in the low familiarity condition of Experiment 3, we found evidence of an early frontocentral ERP component at 320 ms poststimulus (the FN320) that was sensitive to the manipulation of bias via instruction, with more negative amplitudes indexing more liberal bias. By contrast, later during the trial (500–700 ms poststimulus), bias effects interacted with old/new effects across all three experiments. Results suggest that the decision criterion is typically activated early during recognition memory trials, and is integrated with retrieved memory signals and task-specific processing demands later during the trial. More generally, the findings demonstrate how ERPs can help to specify the dynamics of recognition memory processes under top-down and bottom-up controlled retrieval conditions. PMID

  7. The development of control processes supporting source memory discrimination as revealed by event-related potentials.

    Science.gov (United States)

    de Chastelaine, Marianne; Friedman, David; Cycowicz, Yael M

    2007-08-01

    Improvement in source memory performance throughout childhood is thought to be mediated by the development of executive control. As postretrieval control processes may be better time-locked to the recognition response rather than the retrieval cue, the development of processes underlying source memory was investigated with both stimulus- and response-locked event-related potentials (ERPs). These were recorded in children, adolescents, and adults during a recognition memory exclusion task. Green- and red-outlined pictures were studied, but were tested in black outline. The test requirement was to endorse old items shown in one study color ("targets") and to reject new items along with old items shown in the alternative study color ("nontargets"). Source memory improved with age. All age groups retrieved target and nontarget memories as reflected by reliable parietal episodic memory (EM) effects, a stimulus-locked ERP correlate of recollection. Response-locked ERPs to targets and nontargets diverged in all groups prior to the response, although this occurred at an increasingly earlier time point with age. We suggest these findings reflect the implementation of attentional control mechanisms to enhance target memories and facilitate response selection with the greatest and least success, respectively, in adults and children. In adults only, response-locked ERPs revealed an early-onsetting parietal negativity for nontargets, but not for targets. This was suggested to reflect adults' ability to consistently inhibit prepotent target responses for nontargets. The findings support the notion that the development of source memory relies on the maturation of control processes that serve to enhance accurate selection of task-relevant memories.

  8. Distinct features of auditory steady-state responses as compared to transient event-related potentials.

    Directory of Open Access Journals (Sweden)

    Li Zhang

    Full Text Available Transient event-related potentials (ERPs and steady-state responses (SSRs have been popularly employed to investigate the function of the human brain, but their relationship still remains a matter of debate. Some researchers believed that SSRs could be explained by the linear summation of successive transient ERPs (superposition hypothesis, while others believed that SSRs were the result of the entrainment of a neural rhythm driven by the periodic repetition of a sensory stimulus (oscillatory entrainment hypothesis. In the present study, taking auditory modality as an example, we aimed to clarify the distinct features of SSRs, evoked by the 40-Hz and 60-Hz periodic auditory stimulation, as compared to transient ERPs, evoked by a single click. We observed that (1 SSRs were mainly generated by phase synchronization, while late latency responses (LLRs in transient ERPs were mainly generated by power enhancement; (2 scalp topographies of LLRs in transient ERPs were markedly different from those of SSRs; (3 the powers of both 40-Hz and 60-Hz SSRs were significantly correlated, while they were not significantly correlated with the N1 power in transient ERPs; (4 whereas SSRs were dominantly modulated by stimulus intensity, middle latency responses (MLRs were not significantly modulated by both stimulus intensity and subjective loudness judgment, and LLRs were significantly modulated by subjective loudness judgment even within the same stimulus intensity. All these findings indicated that high-frequency SSRs were different from both MLRs and LLRs in transient ERPs, thus supporting the possibility of oscillatory entrainment hypothesis to the generation of SSRs. Therefore, SSRs could be used to explore distinct neural responses as compared to transient ERPs, and help us reveal novel and reliable neural mechanisms of the human brain.

  9. Isolating event-related potential components associated with voluntary control of visuo-spatial attention.

    Science.gov (United States)

    McDonald, John J; Green, Jessica J

    2008-08-28

    Attention-directing cues presented at fixation evoke several lateralized event-related potential (ERP) components prior to the onset of visual targets. These components have been associated with the control of visuo-spatial attention, but the neuro-cognitive operations and neural generators of the components are still largely unknown. Here, we isolated cue-elicited ERP activity in different ways to home in on different neuro-cognitive operations and to gain a better understanding about the possible neuroanatomical sources of the cue-elicited ERP activities. To isolate lateralized cue-ERP activity, we compared shift-left and shift-right cue ERPs to shift-up cue ERPs. To measure all of the ERP activity related to attentional control, including spatially nonspecific activity that is removed in the process of isolating lateralized cue-ERP components, we compared shift-cue ERPs to neutral-cue (i.e., no-shift) ERPs. Isolated lateralized-ERP activity was seen in the contralateral-occipital lobe in the early phase of the cue-target interval and in the ipsilateral-occipital lobe in the late phase. The later, ipsilateral activity indicates that the late directing attention positivity (LDAP) reflected processing of the to-be-ignored location. The neutral-cue isolation revealed a shift-related positivity over posterior scalp regions and a shift-related negativity over more anterior scalp regions. The spatio-temporal sequence of shift-related activity observed on the scalp, together with estimates of distributed source activity underlying the shift-related ERP components, indicated that frontal and parietal regions of cortex participated in the control of attention and led to pre-target biasing in visual cortical areas.

  10. The neural correlates of economic value and valuation context: An event-related potentials study.

    Science.gov (United States)

    Tyson-Carr, John Andrew; Kokmotou, Katerina; Soto, Vicente; Cook, Stephanie; Fallon, Nicholas B; Giesbrecht, Timo; Stancak, Andrej

    2018-02-14

    The value of environmental cues and internal states is continuously evaluated by the human brain and it is this subjective value that largely guides decision-making. The present study aimed to investigate the initial value attribution process, specifically the spatio-temporal activation patterns associated with values and valuation context using electroencephalographic event-related potentials (ERPs). Participants completed a stimulus rating task in which everyday household items marketed up to a price of £4 were evaluated with respect to their desirability or material properties. The subjective values of items were evaluated as willingness-to-pay (WTP) in a Becker-DeGroot-Marschak auction. Based on the individual's subjective WTP values, the stimuli were divided into high and low value items. Source dipole modelling was applied to estimate the cortical sources underlying ERP components modulated by subjective values (high vs. low WTP) and the evaluation condition (value-relevant vs. value-irrelevant judgments). Low WTP items and value-relevant judgements both led to a more pronounced N2 visual evoked potential at right frontal scalp electrodes. Source activity in right anterior insula and left orbitofrontal cortex was larger for low vs. high WTP at around 200 ms. At a similar latency, source activity in right anterior insula and right parahippocampal gyrus was larger for value-relevant vs. value irrelevant judgements. A stronger response for low- than high-value items in anterior insula and orbitofrontal cortex appears to reflect aversion to low-valued item acquisition which, in an auction experiment, would be perceived as a relative loss. This initial low-value bias occurs automatically irrespective of the valuation context.

  11. Double dissociation between rules and memory in music: an event-related potential study.

    Science.gov (United States)

    Miranda, Robbin A; Ullman, Michael T

    2007-11-01

    Language and music share a number of characteristics. Crucially, both domains depend on both rules and memorized representations. Double dissociations between the neurocognition of rule-governed and memory-based knowledge have been found in language but not music. Here, the neural bases of both of these aspects of music were examined with an event-related potential (ERP) study of note violations in melodies. Rule-only violations consisted of out-of-key deviant notes that violated tonal harmony rules in novel (unfamiliar) melodies. Memory-only violations consisted of in-key deviant notes in familiar well-known melodies; these notes followed musical rules but deviated from the actual melodies. Finally, out-of-key notes in familiar well-known melodies constituted violations of both rules and memory. All three conditions were presented, within-subjects, to healthy young adults, half musicians and half non-musicians. The results revealed a double dissociation, independent of musical training, between rules and memory: both rule violation conditions, but not the memory-only violations, elicited an early, somewhat right-lateralized anterior-central negativity (ERAN), consistent with previous studies of rule violations in music, and analogous to the early left-lateralized anterior negativities elicited by rule violations in language. In contrast, both memory violation conditions, but not the rule-only violation, elicited a posterior negativity that might be characterized as an N400, an ERP component that depends, at least in part, on the processing of representations stored in long-term memory, both in language and in other domains. The results suggest that the neurocognitive rule/memory dissociation extends from language to music, further strengthening the similarities between the two domains.

  12. An event-related potential examination of contour integration deficits in schizophrenia

    Science.gov (United States)

    Butler, Pamela D.; Abeles, Ilana Y.; Silverstein, Steven M.; Dias, Elisa C.; Weiskopf, Nicole G.; Calderone, Daniel J.; Sehatpour, Pejman

    2013-01-01

    Perceptual organization, which refers to the ability to integrate fragments of stimuli to form a representation of a whole edge, part, or object, is impaired in schizophrenia. A contour integration paradigm, involving detection of a set of Gabor patches forming an oval contour pointing to the right or left embedded in a field of randomly oriented Gabors, has been developed for use in clinical trials of schizophrenia. The purpose of the present study was to assess contributions of early and later stages of processing to deficits in contour integration, as well as to develop an event-related potential (ERP) analog of this task. Twenty-one patients with schizophrenia and 28 controls participated. The Gabor elements forming the contours were given a low or high degree of orientational jitter, making it either easy or difficult to identify the direction in which the contour was pointing. ERP results showed greater negative peaks at ~165 (N1 component) and ~270 ms for the low-jitter versus the high-jitter contours, with a much greater difference between jitter conditions at 270 ms. This later ERP component was previously termed Ncl for closure negativity. Source localization identified the Ncl in the lateral occipital object recognition area. Patients showed a significant decrease in the Ncl, but not N1, compared to controls, and this was associated with impaired behavioral ability to identify contours. In addition, an earlier negative peak was found at ~120 ms (termed N120) that differentiated jitter conditions, had a dorsal stream source, and differed between patients and controls. Patients also showed a deficit in the dorsal stream sensory P1 component. These results are in accord with impairments in distributed circuitry contributing to perceptual organization deficits and provide an ERP analog to the behavioral contour integration task. PMID:23519476

  13. Using event related potentials to identify a user's behavioural intention aroused by product form design.

    Science.gov (United States)

    Ding, Yi; Guo, Fu; Zhang, Xuefeng; Qu, Qingxing; Liu, Weilin

    2016-07-01

    The capacity of product form to arouse user's behavioural intention plays a decisive role in further user experience, even in purchase decision, while traditional methods rarely give a fully understanding of user experience evoked by product form, especially the feeling of anticipated use of product. Behavioural intention aroused by product form designs has not yet been investigated electrophysiologically. Hence event related potentials (ERPs) were applied to explore the process of behavioural intention when users browsed different smart phone form designs with brand and price not taken into account for mainly studying the brain activity evoked by variety of product forms. Smart phone pictures with different anticipated user experience were displayed with equiprobability randomly. Participants were asked to click the left mouse button when certain picture gave them a feeling of behavioural intention to interact with. The brain signal of each participant was recorded by Curry 7.0. The results show that pictures with an ability to arouse participants' behavioural intention for further experience can evoke enhanced N300 and LPPs (late positive potentials) in central-parietal, parietal and occipital regions. The scalp topography shows that central-parietal, parietal and occipital regions are more activated. The results indicate that the discrepancy of ERPs can reflect the neural activities of behavioural intention formed or not. Moreover, amplitude of ERPs occurred in corresponding brain areas can be used to measure user experience. The exploring of neural correlated with behavioural intention provide an accurate measurement method of user's perception and help marketers to know which product can arouse users' behavioural intention, maybe taken as an evaluating indicator of product design. Copyright © 2016 Elsevier Ltd and The Ergonomics Society. All rights reserved.

  14. Auditory selective attention in adolescents with major depression: An event-related potential study.

    Science.gov (United States)

    Greimel, E; Trinkl, M; Bartling, J; Bakos, S; Grossheinrich, N; Schulte-Körne, G

    2015-02-01

    Major depression (MD) is associated with deficits in selective attention. Previous studies in adults with MD using event-related potentials (ERPs) reported abnormalities in the neurophysiological correlates of auditory selective attention. However, it is yet unclear whether these findings can be generalized to MD in adolescence. Thus, the aim of the present ERP study was to explore the neural mechanisms of auditory selective attention in adolescents with MD. 24 male and female unmedicated adolescents with MD and 21 control subjects were included in the study. ERPs were collected during an auditory oddball paradigm. Depressive adolescents tended to show a longer N100 latency to target and non-target tones. Moreover, MD subjects showed a prolonged latency of the P200 component to targets. Across groups, longer P200 latency was associated with a decreased tendency of disinhibited behavior as assessed by a behavioral questionnaire. To be able to draw more precise conclusions about differences between the neural bases of selective attention in adolescents vs. adults with MD, future studies should include both age groups and apply the same experimental setting across all subjects. The study provides strong support for abnormalities in the neurophysiolgical bases of selective attention in adolecents with MD at early stages of auditory information processing. Absent group differences in later ERP components reflecting voluntary attentional processes stand in contrast to results reported in adults with MD and may suggest that adolescents with MD possess mechanisms to compensate for abnormalities in the early stages of selective attention. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. The neural basis of analogical reasoning: an event-related potential study.

    Science.gov (United States)

    Qiu, Jiang; Li, Hong; Chen, Antao; Zhang, Qinglin

    2008-10-01

    The spatiotemporal analysis of brain activation during the execution of easy analogy (EA) and difficult analogy (DA) tasks was investigated using high-density event-related brain potentials (ERPs). Results showed that reasoning tasks (schema induction) elicited a more negative ERP deflection (N500-1000) than did the baseline task (BS) between 500 and 1000 ms. Dipole source analysis of difference waves (EA-BS and DA-BS) indicated that the negative components were both localized near the left thalamus, possibly associated with the retrieval of alphabetical information. Furthermore, DA elicited a more positive ERP component (P600-1000) than did EA in the same time window. Two generators of P600-1000 were located in the medial prefrontal cortex (BA10) and the left frontal cortex (BA6) which was possibly involved in integrating information in schema abstraction. In the stage of analogy mapping, a greater negativity (N400-600) in the reasoning tasks as compared to BS was found over fronto-central scalp regions. A generator of this effect was located in the left fusiform gyrus and was possibly related to associative memory and activation of schema. Then, a greater negativity in the reasoning tasks, in comparison to BS task, developed between 900-1200 ms (LNC1) and 2000-2500 ms (LNC2). Dipole source analysis (EA-BS) localized the generator of LNC1 in the left prefrontal cortex (BA 10) which was possibly related to mapping the schema to the target problem, and the generator of LNC2 in the left prefrontal cortex (BA 9) which was possibly related to deciding whether a conclusion correctly follows from the schema.

  16. The neuromechanism underlying verbal analogical reasoning of metaphorical relations: an event-related potentials study.

    Science.gov (United States)

    Zhao, Ming; Meng, Huishan; Xu, Zhiyuan; Du, Fenglei; Liu, Tao; Li, Yongxin; Chen, Feiyan

    2011-11-24

    Using event-related potentials (ERPs), this study investigated the neuromechanism underlying verbal analogical reasoning of two different metaphorical relations: attributive metaphor and relational metaphor. The analogical reasoning of attributive metaphor (AM-AR) involves a superficial similarity between analogues, while the analogical reasoning of relational metaphor (RM-AR) requires a structural similarity. Subjects were asked to judge whether one word pair was semantically analogous to another word pair. Results showed that the schema induction stage elicited a greater N400 component at the right anterior scalp for the AM-AR and RM-AR tasks, possibly attributable to semantic processing of metaphorical word pairs. The N400 was then followed by a widely distributed P300 and a late negative component (LNC1) at the left anterior scalp. The P300 was possibly related to the formation of a relational category, while the LNC1 was possibly related to the maintenance of a reasoning cue in working memory. The analogy mapping stage elicited broadly distributed N400 and LNC2, which might indicate the presence of semantic retrieval and analogical transfer. In the answer production stage, all conditions elicited the P2 component due to early stimulus encoding. The largest P2 amplitude was in the RM-AR task. The RM-AR elicited a larger LPC than did the AM-AR, even though the baseline correction was taken as a control for the differential P2 effect. The LPC effect might suggest that relational metaphors involved more integration processing than attributive metaphors. Copyright © 2011 Elsevier B.V. All rights reserved.

  17. Fluid Intelligence and Automatic Neural Processes in Facial Expression Perception: An Event-Related Potential Study.

    Science.gov (United States)

    Liu, Tongran; Xiao, Tong; Li, Xiaoyan; Shi, Jiannong

    2015-01-01

    The relationship between human fluid intelligence and social-emotional abilities has been a topic of considerable interest. The current study investigated whether adolescents with different intellectual levels had different automatic neural processing of facial expressions. Two groups of adolescent males were enrolled: a high IQ group and an average IQ group. Age and parental socioeconomic status were matched between the two groups. Participants counted the numbers of the central cross changes while paired facial expressions were presented bilaterally in an oddball paradigm. There were two experimental conditions: a happy condition, in which neutral expressions were standard stimuli (p = 0.8) and happy expressions were deviant stimuli (p = 0.2), and a fearful condition, in which neutral expressions were standard stimuli (p = 0.8) and fearful expressions were deviant stimuli (p = 0.2). Participants were required to concentrate on the primary task of counting the central cross changes and to ignore the expressions to ensure that facial expression processing was automatic. Event-related potentials (ERPs) were obtained during the tasks. The visual mismatch negativity (vMMN) components were analyzed to index the automatic neural processing of facial expressions. For the early vMMN (50-130 ms), the high IQ group showed more negative vMMN amplitudes than the average IQ group in the happy condition. For the late vMMN (320-450 ms), the high IQ group had greater vMMN responses than the average IQ group over frontal and occipito-temporal areas in the fearful condition, and the average IQ group evoked larger vMMN amplitudes than the high IQ group over occipito-temporal areas in the happy condition. The present study elucidated the close relationships between fluid intelligence and pre-attentive change detection on social-emotional information.

  18. Localizing Event-Related Potentials Using Multi-source Minimum Variance Beamformers: A Validation Study.

    Science.gov (United States)

    Herdman, Anthony T; Moiseev, Alexander; Ribary, Urs

    2018-02-15

    Adaptive and non-adaptive beamformers have become a prominent neuroimaging tool for localizing neural sources of electroencephalographic (EEG) and magnetoencephalographic (MEG) data. In this study, we investigated single-source and multi-source scalar beamformers with respect to their performances in localizing and reconstructing source activity for simulated and real EEG data. We compared a new multi-source search approach (multi-step iterative approach; MIA) to our previous multi-source search approach (single-step iterative approach; SIA) and a single-source search approach (single-step peak approach; SPA). In order to compare performances across these beamformer approaches, we manipulated various simulated source parameters, such as the amount of signal-to-noise ratio (0.1-0.9), inter-source correlations (0.3-0.9), number of simultaneously active sources (2-8), and source locations. Results showed that localization performance followed the order of MIA > SIA > SPA regardless of the number of sources, source correlations, and single-to-noise ratios. In addition, SIA and MIA were significantly better than SPA at localizing four or more sources. Moreover, MIA was better than SIA and SPA at identifying the true source locations when signal characteristics were at their poorest. Source waveform reconstructions were similar between MIA and SIA but were significantly better than that for SPA. A similar trend was also found when applying these beamformer approaches to a real EEG dataset. Based on our findings, we conclude that multi-source beamformers (MIA and SIA) are an improvement over single-source beamformers for localizing EEG. Importantly, our new search method, MIA, had better localization performance, localization precision, and source waveform reconstruction as compared to SIA or SPA. We therefore recommend its use for improved source localization and waveform reconstruction of event-related potentials.

  19. High resolution event-related potentials analysis of the arithmetic-operation effect in mental arithmetic.

    Science.gov (United States)

    Muluh, E T; Vaughan, C L; John, L R

    2011-03-01

    Early, late and slow waves of event-related potentials (erps) appearing around 0-300 ms, 300-500 ms and after 500 ms respectively post-question presentation have been differentially associated to mental arithmetic processing (MAP). We hypothesized that arithmetic-operation effect (AOE) will show greater modulation of early components (P100, P200) in high-frequency erps; late components (P300, N300) and slow waves in low-frequency ERP when large-size problems are employed. Fourteen normal human subjects mentally processed large- and small-size addition, division, multiplication and subtraction problems. Spatiotemporal differences between these arithmetic-operations were studied by way of comparing amplitudes and latencies of early, late and slow waves. All components were modulated by AOE. Modulated was observed as early as 100 ms post-question presentation (in high-frequency ERP components). AOE was very pronounced in large-size problems (in low-frequency ERP components). Results suggest that modulation by AOE of ERP components is improved when large-size problems and low-frequency ERP components are employed. Thus, differentiation of neuropsychological processes manifested by amplitude and latency of ERP components may be best studied by first separating components into high- and low-frequency erps. Findings raise the potential of obtaining ERP indices that may improve findings about the degree (and time) of engagement of cognitive processes (e.g. Strategy employed in MAP). Copyright © 2010 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  20. Natural speech comprehension in bipolar disorders: an event-related brain potential study among manic patients.

    Science.gov (United States)

    Cermolacce, Michel; Faugère, Mélanie; Micoulaud-Franchi, Jean-Arthur; Belzeaux, Raoul; Maurel, Muriel; Naudin, Jean; Azorin, Jean-Michel; Vion-Dury, Jean

    2014-04-01

    Thought and language disturbances are crucial clinical features in Bipolar Disorders (BD), and constitute a fundamental basis for social cognition. In BD, clinical manifestations such as disorganization and formal thought disorders may play a role in communication disturbances. However, only few studies have explored language disturbances in BD at a neurophysiological level. Two main Event-Related brain Potentials (ERPs) have been used in language comprehension research: the N400 component, elicited by incongruous word with the preceding semantic context, and the Late Positive Component (LPC), associated with non-specifically semantic and more general cognitive processes. Previous studies provided contradictory results regarding N400 in mood disorders, showing either preserved N400 in depression or dysthymia, or altered N400 in BD during semantic priming paradigm. The aim of our study was to explore N400 and LPC among patients with BD in natural speech conditions. ERPs from 19 bipolar type I patients with manic or hypomanic symptomatology and 19 healthy controls were recorded. Participants were asked to listen to congruous and incongruous complete sentences and to judge the match between the final word and the sentence context. Behavioral results and ERPs data were analyzed. At the behavioral level, patients with BD show worst performances than healthy participants. At the electrophysiological level, our results show preserved N400 component in BD. LPC elicited under natural speech conditions shows preserved amplitude but delayed latency in difference waves. Small size of samples, absence of schizophrenic group and medication status. In contrast with the only previous N400 study in BD that uses written semantic priming, our results show a preserved N400 component in ecological and natural speech conditions among patients with BD. Possible implications in terms of clinical specificity are discussed. Copyright © 2013 Elsevier B.V. All rights reserved.

  1. Event-related potential studies of outcome processing and feedback-guided learning

    Directory of Open Access Journals (Sweden)

    René eSan Martín

    2012-11-01

    Full Text Available In order to control behavior in an adaptive manner the brain has to learn how some situations and actions predict positive or negative outcomes. During the last decade cognitive neuroscientists have shown that the brain is able to evaluate and learn from outcomes within a few hundred milliseconds of their occurrence. This research has been primarily focused on the feedback-related negativity (FRN and the P3, two event-related potential (ERP components that are elicited by outcomes. The FRN is a frontally distributed negative-polarity ERP component that typically reaches its maximal amplitude 250 ms after outcome presentation and tends to be larger for negative than for positive outcomes. The FRN has been associated with activity in the anterior cingulate cortex. The P3 (~300-600 ms is a parietally distributed positive-polarity ERP component that tends to be larger for large magnitude than for small magnitude outcomes. The neural sources of the P3 are probably distributed over different regions of the cortex. This paper examines the theories that have been proposed to explain the functional role of these two ERP components during outcome processing. Special attention is paid to extant literature addressing how these ERP components are modulated by outcome valence (negative vs. positive, outcome magnitude (large vs. small, outcome probability (unlikely vs. likely and behavioral adjustment. The literature offers few generalizable conclusions, but is beset with a number of inconsistencies across studies. This paper discusses the potential reasons for these inconsistencies and points out some challenges that will shape the field over the next decade.

  2. Increased event-related potentials and alpha-, beta- and gamma-activity associated with intentional actions

    Directory of Open Access Journals (Sweden)

    Susanne eKarch

    2016-01-01

    Full Text Available Objective: Internally guided actions are defined as being purposeful, self-generated and offering choices between alternatives. Intentional actions are essential to reach individual goals. In previous empirical studies, internally guided actions were predominantly related to functional responses in frontal and parietal areas. The aim of the present study was to distinguish event-related potentials and oscillatory responses of intentional actions and externally guided actions. In addition, we compared neurobiological findings of the decision which action to perform with those referring to the decision whether or not to perform an action. Methods: Twenty-eight subjects participated in adapted go/nogo paradigms, including a voluntary selection condition allowing participants to [1] freely decide whether to press the response button or [2] to decide whether they wanted to press the response button with the right index finger or the left index finger. Results: The reaction times were increased when participants freely decided whether and how they wanted to respond compared to the go condition. Intentional processes were associated with a fronto-centrally located N2 and P3 potential. N2 and P3 amplitudes were increased during intentional actions compared to instructed responses (go. In addition, increased activity in the alpha-, beta- and gamma-frequency range was shown during voluntary behaviour rather than during externally-guided responses. Conclusion: These results may indicate that an additional cognitive process is needed for intentional actions compared to instructed behaviour. However, the neural responses were comparatively independent of the kind of decision that was made (1. decision which action to perform; 2. decision whether or not to perform an action. Significance: The study demonstrates the importance of fronto-central alpha-, beta- and gamma oscillations for voluntary behaviour.

  3. Feature extraction of event-related potentials using wavelets: an application to human performance monitoring

    Science.gov (United States)

    Trejo, L. J.; Shensa, M. J.

    1999-01-01

    This report describes the development and evaluation of mathematical models for predicting human performance from discrete wavelet transforms (DWT) of event-related potentials (ERP) elicited by task-relevant stimuli. The DWT was compared to principal components analysis (PCA) for representation of ERPs in linear regression and neural network models developed to predict a composite measure of human signal detection performance. Linear regression models based on coefficients of the decimated DWT predicted signal detection performance with half as many free parameters as comparable models based on PCA scores. In addition, the DWT-based models were more resistant to model degradation due to over-fitting than PCA-based models. Feed-forward neural networks were trained using the backpropagation algorithm to predict signal detection performance based on raw ERPs, PCA scores, or high-power coefficients of the DWT. Neural networks based on high-power DWT coefficients trained with fewer iterations, generalized to new data better, and were more resistant to overfitting than networks based on raw ERPs. Networks based on PCA scores did not generalize to new data as well as either the DWT network or the raw ERP network. The results show that wavelet expansions represent the ERP efficiently and extract behaviorally important features for use in linear regression or neural network models of human performance. The efficiency of the DWT is discussed in terms of its decorrelation and energy compaction properties. In addition, the DWT models provided evidence that a pattern of low-frequency activity (1 to 3.5 Hz) occurring at specific times and scalp locations is a reliable correlate of human signal detection performance. Copyright 1999 Academic Press.

  4. Effects of significance of auditory location changes on event related brain potentials and pitch discrimination performance.

    Science.gov (United States)

    Koistinen, Sonja; Rinne, Teemu; Cederström, Sebastian; Alho, Kimmo

    2012-01-03

    We examined effects of significance of task irrelevant changes in the location of tones on the mismatch negativity (MMN) and P3a event related brain potentials. The participants were to discriminate between two frequency modulated tones differing from each other in the direction of frequency glide. Each tone was delivered through one of five loudspeakers in front of the participant. On most trials, a tone was presented from the same location as the preceding tone, but occasionally the location changed. In the Varying Location Condition, these changes, although irrelevant with regard to pitch discrimination, were still significant for performance as the following tones were presented from the new location where attention had to be therefore shifted. In the Fixed Location Condition, the location changes were less significant as the tones following a location change were presented from the original location. In both conditions, the location changes were associated with decreased hit rates and increased reaction times in the pitch discrimination task. However, the hit rate decrease was larger in the Fixed Location Condition suggesting that in this condition the location changes were just distractors. MMN and P3a responses were elicited by location changes in both conditions. In the Fixed Location Condition, a P3a was also elicited by the first tone following a location change at the original location while the MMN was not. Thus, the P3a appeared to be related to shifting of attention in space and was not tightly coupled with MMN elicitation. Copyright © 2011 Elsevier B.V. All rights reserved.

  5. Disentangling the Attention Network Test: Behavioral, Event Related Potentials and neural source analyses.

    Directory of Open Access Journals (Sweden)

    Alejandro eGalvao-Carmona

    2014-10-01

    Full Text Available Background. The study of the attentional system remains a challenge for current neuroscience. The Attention Network Test (ANT was designed to study simultaneously three different attentional networks (alerting, orienting and executive based in subtraction of different experimental conditions. However, some studies recommend caution with these calculations due to the interactions between the attentional networks. In particular, it is highly relevant that several interpretations about attentional impairment have arisen from these calculations in diverse pathologies. Event Related Potentials (ERPs and neural source analysis can be applied to disentangle the relationships between these attentional networks not specifically shown by behavioural measures. Results. This study shows that there is a basic level of alerting (tonic alerting in the no cue condition, represented by a slow negative trend in the ERP trace prior to the onset of the target stimuli. A progressive increase in the CNV amplitude related to the amount of information provided by the cue conditions is also shown. Neural source analysis reveals specific modulations of the CNV related to a task-related expectancy presented in the no cue condition; a late modulation triggered by the central cue condition and probably representing a generic motor preparation; and an early and late modulation for spatial cue condition suggesting specific motor and sensory preactivation. Finally, the first component in the information processing of the target stimuli modulated by the interaction between orienting network and the executive system can be represented by N1. Conclusions. The ANT is useful as a paradigm to study specific attentional mechanisms and their interactions. However, calculation of network effects is based in subtractions with non-comparable experimental conditions, as evidenced by the present data, which can induce misinterpretations in the study of the attentional capacity in human

  6. Event-related potentials during forced awakening: a tool for the study of acute sleep inertia.

    Science.gov (United States)

    Bastuji, Hélène; Perrin, Fabien; Garcia-Larrea, Luis

    2003-09-01

    Sleep propensity and sleep inertia were assessed in 43 patients with excessive daytime sleepiness (EDS) and 21 sleep-deprived controls, using a forced awakening test under continuous electroencephalographic (EEG) recording. Event-related potentials (ERPs) were first obtained in waking, while participants performed a target detection auditory task. Subjects were then allowed to take a nap with lights off and sleep latency was calculated. After 3 min of continuous sleep, frequent and rare tones were suddenly presented again (and ERPs recorded) in a forced awakening condition, which was repeated a second time if patients fell asleep. ERPs in pre-nap wakefulness did not differ in patients and controls. On forced awakening, almost half (48%) of EDS patients retained morphologically normal ERPs, but showed a significant delay of P300 relative to waking. In the other half of the patients (and none of the controls), the N200/P300 complex to targets was replaced on forced awakening by high-amplitude negative waves ('sleep negativities'). Single subject analysis showed that 65% of patients had abnormal responses during forced awakening (significant P3 delay or sleep negativities), while only three of them (7%) had abnormal ERPs on wakefulness. The presence of sleep negativities was associated with shorter sleep latencies and increased target detection errors on forced awakening. Sleep negativities were more prevalent in narcolepsy and idiopathic hypersomnia than in EDS associated to psychiatric disorders. By combining sleep latency and ERP measures, the forced awakening test provided a robust and relatively rapid tool (45-60 min) to evaluate both sleep propensity and sleep inertia within a single recording session. The test allows each subject to act as his/her own control, thus increasing sensitivity. In the present series, it proved to be much more discriminative than waking ERPs alone to demonstrate specific abnormalities in patients complaining of excessive daytime

  7. An Event-Related Potential Examination of Contour Integration Deficits in Schizophrenia

    Directory of Open Access Journals (Sweden)

    Pamela D Butler

    2013-03-01

    Full Text Available Perceptual organization, which refers to the ability to integrate fragments of stimuli to form a representation of a whole edge, part, or object, is impaired in schizophrenia. A contour integration paradigm, involving detection of a set of Gabor patches forming an oval contour pointing to the right or left embedded in a field of randomly oriented Gabors, has been developed for use in clinical trials of schizophrenia. The purpose of the present study was to assess contributions of early and later stages of processing to deficits in contour integration, as well as to develop an event-related potential (ERP analog of this task. Twenty-one patients with schizophrenia and 28 controls participated. The Gabor elements forming the contours were given a low or high degree of orientational jitter, making it either easy or difficult to identify the direction in which the contour was pointing. ERP results showed greater negative peaks at ~165 (N1 component and ~270 ms for the low-jitter versus the high-jitter contours, with a much greater difference between jitter conditions at 270 ms. This later ERP component was previously termed Ncl for closure negativity. Source localization identified the Ncl in the lateral occipital object recognition area. Patients showed a significant decrease in the Ncl, but not N1, compared to controls, and this was associated with impaired behavioral ability to identify contours. In addition, an earlier negative peak was found at ~120 ms (termed N120 that differentiated jitter conditions, had a dorsal stream source, and differed between patients and controls. Patients also showed a deficit in the dorsal stream sensory P1 component. These results are in accord with impairments in distributed circuitry contributing to perceptual organization deficits and provide an ERP analog to the behavioral contour integration task.

  8. Differential beta-band event-related desynchronization during categorical action sequence planning.

    Science.gov (United States)

    Park, Hame; Kim, June Sic; Chung, Chun Kee

    2013-01-01

    A primate study reported the existence of neurons from the dorso-lateral prefrontal cortex which fired prior to executing categorical action sequences. The authors suggested these activities may represent abstract level information. Here, we aimed to find the neurophysiological representation of planning categorical action sequences at the population level in healthy humans. Previous human studies have shown beta-band event-related desynchronization (ERD) during action planning in humans. Some of these studies showed different levels of ERD according to different types of action preparation. Especially, the literature suggests that variations in cognitive factors rather than physical factors (force, direction, etc) modulate the level of beta-ERD. We hypothesized that the level of beta-band power will differ according to planning of different categorical sequences. We measured magnetoencephalography (MEG) from 22 subjects performing 11 four-sequence actions--each consisting of one or two of three simple actions--in 3 categories; 'Paired (ooxx)', 'Alternative (oxox)' and 'Repetitive (oooo)' ('o' and 'x' each denoting one of three simple actions). Time-frequency representations were calculated for each category during the planning period, and the corresponding beta-power time-courses were compared. We found beta-ERD during the planning period for all subjects, mostly in the contralateral fronto-parietal areas shortly after visual cue onset. Power increase (transient rebound) followed ERD in 20 out of 22 subjects. Amplitudes differed among categories in 20 subjects for both ERD and transient rebound. In 18 out of 20 subjects 'Repetitive' category showed the largest ERD and rebound. The current result suggests that beta-ERD in the contralateral frontal/motor/parietal areas during planning is differentiated by the category of action sequences.

  9. Competitive Semantic Memory Retrieval: Temporal Dynamics Revealed by Event-Related Potentials.

    Directory of Open Access Journals (Sweden)

    Robin Hellerstedt

    Full Text Available Memories compete for retrieval when they are related to a common retrieval cue. Previous research has shown that retrieval of a target memory may lead to subsequent retrieval-induced forgetting (RIF of currently irrelevant competing memories. In the present study, we investigated the time course of competitive semantic retrieval and examined the neurocognitive mechanisms underlying RIF. We contrasted two theoretical accounts of RIF by examining a critical aspect of this memory phenomenon, namely the extent to which it depends on successful retrieval of the target memory. Participants first studied category-exemplar word-pairs (e.g. Fruit-Apple. Next, we recorded electrophysiological measures of brain activity while the participants performed a competitive semantic cued-recall task. In this task, the participants were provided with the studied categories but they were instructed to retrieve other unstudied exemplars (e.g. Fruit-Ma__?. We investigated the event-related potential (ERP correlates of retrieval success by comparing ERPs from successful and failed retrieval trials. To isolate the ERP correlates of continuous retrieval attempts from the ERP correlates of retrieval success, we included an impossible retrieval condition, with incompletable word-stem cues (Drinks-Wy__ and compared it with a non-retrieval presentation baseline condition (Occupation-Dentist. The participants' memory for all the studied exemplars was tested in the final phase of the experiment. Taken together, the behavioural results suggest that RIF is independent of target retrieval. Beyond investigating the mechanisms underlying RIF, the present study also elucidates the temporal dynamics of semantic cued-recall by isolating the ERP correlates of retrieval attempt and retrieval success. The ERP results revealed that retrieval attempt is reflected in a late posterior negativity, possibly indicating construction of candidates for completing the word-stem cue and retrieval

  10. Examining Event-Related Potential (ERP) correlates of decision bias in recognition memory judgments.

    Science.gov (United States)

    Hill, Holger; Windmann, Sabine

    2014-01-01

    Memory judgments can be based on accurate memory information or on decision bias (the tendency to report that an event is part of episodic memory when one is in fact unsure). Event related potentials (ERP) correlates are important research tools for elucidating the dynamics underlying memory judgments but so far have been established only for investigations of accurate old/new discrimination. To identify the ERP correlates of bias, and observe how these interact with ERP correlates of memory, we conducted three experiments that manipulated decision bias within participants via instructions during recognition memory tests while their ERPs were recorded. In Experiment 1, the bias manipulation was performed between blocks of trials (automatized bias) and compared to trial-by-trial shifts of bias in accord with an external cue (flexibly controlled bias). In Experiment 2, the bias manipulation was performed at two different levels of accurate old/new discrimination as the memory strength of old (studied) items was varied. In Experiment 3, the bias manipulation was added to another, bottom-up driven manipulation of bias induced via familiarity. In the first two Experiments, and in the low familiarity condition of Experiment 3, we found evidence of an early frontocentral ERP component at 320 ms poststimulus (the FN320) that was sensitive to the manipulation of bias via instruction, with more negative amplitudes indexing more liberal bias. By contrast, later during the trial (500-700 ms poststimulus), bias effects interacted with old/new effects across all three experiments. Results suggest that the decision criterion is typically activated early during recognition memory trials, and is integrated with retrieved memory signals and task-specific processing demands later during the trial. More generally, the findings demonstrate how ERPs can help to specify the dynamics of recognition memory processes under top-down and bottom-up controlled retrieval conditions.

  11. Automatic Conflict Monitoring by Event-Related Potentials Could be used to Estimate Visual Acuity Levels.

    Science.gov (United States)

    Huang, Wenwen; Liu, Sinan; Luo, Bin; Meng, Huanhuan; Ji, Mengmeng; Li, Maojuan; Chen, Xiping; Tao, Luyang

    2018-03-15

    Numerous studies have explored the physical attribute features or face perceptions in conflict processing, while complicate gradient conflicts were rarely discussed. The aim of the study was to discuss the relationship between the event-related potential (ERP) component features and different visual acuity levels by using the modified S1-S2 task under non-attention status. Three visual acuity levels were applied, each with four orientations of "E" optotype stimuli randomly presented in the center of the visual field while participants were required to concentrate on listening to stories. The results showed that the amplitudes of P1 and P3 as well as difference P3 were larger in supra-threshold condition. In threshold condition, larger amplitudes for both N2 and difference N2 exhibited in frontal and central areas. In sub-threshold condition, there was no endogenous component elicited by mismatch stimuli except smaller anterior N1. Meanwhile, the specific distributions of N1 and N2 were presented and compared with previous face processing. The findings showed that visual conflict processing took place not only at an early stage but also at the late period, which might be as the consequences of interaction between conflict strength and involuntary attention. We concluded that automatic conflict detecting of visual icons by the serial ERP components could distinguish different visual acuity levels. The involvement of endogenous components could reveal the specific mechanism of more precise and fine conflict identification of complex physical attributes under non-attention status, furthermore could be used as valid markers to estimate the magnitude of visual acuity objectively. Copyright © 2018 IBRO. Published by Elsevier Ltd. All rights reserved.

  12. Statistical analysis of event-related potential elicited by verb-complement merge in Brazilian Portuguese

    Directory of Open Access Journals (Sweden)

    M. Cagy

    2006-11-01

    Full Text Available An interesting fact about language cognition is that stimulation involving incongruence in the merge operation between verb and complement has often been related to a negative event-related potential (ERP of augmented amplitude and latency of ca. 400 ms - the N400. Using an automatic ERP latency and amplitude estimator to facilitate the recognition of waves with a low signal-to-noise ratio, the objective of the present study was to study the N400 statistically in 24 volunteers. Stimulation consisted of 80 experimental sentences (40 congruous and 40 incongruous, generated in Brazilian Portuguese, involving two distinct local verb-argument combinations (nominal object and pronominal object series. For each volunteer, the EEG was simultaneously acquired at 20 derivations, topographically localized according to the 10-20 International System. A computerized routine for automatic N400-peak marking (based on the ascendant zero-cross of the first waveform derivative was applied to the estimated individual ERP waveform for congruous and incongruous sentences in both series for all ERP topographic derivations. Peak-to-peak N400 amplitude was significantly augmented (P < 0.05; one-sided Wilcoxon signed-rank test due to incongruence in derivations F3, T3, C3, Cz, T5, P3, Pz, and P4 for nominal object series and in P3, Pz and P4 for pronominal object series. The results also indicated high inter-individual variability in ERP waveforms, suggesting that the usual procedure of grand averaging might not be considered a generally adequate approach. Hence, signal processing statistical techniques should be applied in neurolinguistic ERP studies allowing waveform analysis with low signal-to-noise ratio.

  13. Fluid Intelligence and Automatic Neural Processes in Facial Expression Perception: An Event-Related Potential Study.

    Directory of Open Access Journals (Sweden)

    Tongran Liu

    Full Text Available The relationship between human fluid intelligence and social-emotional abilities has been a topic of considerable interest. The current study investigated whether adolescents with different intellectual levels had different automatic neural processing of facial expressions. Two groups of adolescent males were enrolled: a high IQ group and an average IQ group. Age and parental socioeconomic status were matched between the two groups. Participants counted the numbers of the central cross changes while paired facial expressions were presented bilaterally in an oddball paradigm. There were two experimental conditions: a happy condition, in which neutral expressions were standard stimuli (p = 0.8 and happy expressions were deviant stimuli (p = 0.2, and a fearful condition, in which neutral expressions were standard stimuli (p = 0.8 and fearful expressions were deviant stimuli (p = 0.2. Participants were required to concentrate on the primary task of counting the central cross changes and to ignore the expressions to ensure that facial expression processing was automatic. Event-related potentials (ERPs were obtained during the tasks. The visual mismatch negativity (vMMN components were analyzed to index the automatic neural processing of facial expressions. For the early vMMN (50-130 ms, the high IQ group showed more negative vMMN amplitudes than the average IQ group in the happy condition. For the late vMMN (320-450 ms, the high IQ group had greater vMMN responses than the average IQ group over frontal and occipito-temporal areas in the fearful condition, and the average IQ group evoked larger vMMN amplitudes than the high IQ group over occipito-temporal areas in the happy condition. The present study elucidated the close relationships between fluid intelligence and pre-attentive change detection on social-emotional information.

  14. Attention bias in earthquake-exposed survivors: an event-related potential study.

    Science.gov (United States)

    Zhang, Yan; Kong, Fanchang; Han, Li; Najam Ul Hasan, Abbasi; Chen, Hong

    2014-12-01

    The Chinese Wenchuan earthquake, which happened on the 28th of May in 2008, may leave deep invisible scars in individuals. China has a large number of children and adolescents, who tend to be most vulnerable because they are in an early stage of human development and possible post-traumatic psychological distress may have a life-long consequence. Trauma survivors without post-traumatic stress disorder (PTSD) have received little attention in previous studies, especially in event-related potential (ERP) studies. We compared the attention bias to threat stimuli between the earthquake-exposed group and the control group in a masked version of the dot probe task. The target probe presented at the same space location consistent with earthquake-related words was the congruent trial, while in the space location of neutral words was the incongruent trial. Thirteen earthquake-exposed middle school students without PTSD and 13 matched controls were included in this investigation. The earthquake-exposed group showed significantly faster RTs to congruent trials than to incongruent trials. The earthquake-exposed group produced significantly shorter C1 and P1 latencies and larger C1, P1 and P2 amplitudes than the control group. In particular, enhanced P1 amplitude to threat stimuli was observed in the earthquake-exposed group. These findings are in agreement with the prediction that earthquake-exposed survivors have an attention bias to threat stimuli. The traumatic event had a much greater effect on earthquake-exposed survivors even if they showed no PTSD symptoms than individuals in the controls. These results will provide neurobiological evidences for effective intervention and prevention to post-traumatic mental problems. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Single-Trial Event-Related Potential Correlates of Belief Updating

    Science.gov (United States)

    Murawski, Carsten; Bode, Stefan

    2015-01-01

    Abstract Belief updating—the process by which an agent alters an internal model of its environment—is a core function of the CNS. Recent theory has proposed broad principles by which belief updating might operate, but more precise details of its implementation in the human brain remain unclear. In order to address this question, we studied how two components of the human event-related potential encoded different aspects of belief updating. Participants completed a novel perceptual learning task while electroencephalography was recorded. Participants learned the mapping between the contrast of a dynamic visual stimulus and a monetary reward and updated their beliefs about a target contrast on each trial. A Bayesian computational model was formulated to estimate belief states at each trial and was used to quantify the following two variables: belief update size and belief uncertainty. Robust single-trial regression was used to assess how these model-derived variables were related to the amplitudes of the P3 and the stimulus-preceding negativity (SPN), respectively. Results showed a positive relationship between belief update size and P3 amplitude at one fronto-central electrode, and a negative relationship between SPN amplitude and belief uncertainty at a left central and a right parietal electrode. These results provide evidence that belief update size and belief uncertainty have distinct neural signatures that can be tracked in single trials in specific ERP components. This, in turn, provides evidence that the cognitive mechanisms underlying belief updating in humans can be described well within a Bayesian framework. PMID:26473170

  16. Episodic Memory in Former Professional Football Players with a History of Concussion: An Event-Related Functional Neuroimaging Study

    OpenAIRE

    Ford, Jaclyn H.; Giovanello, Kelly S.; Guskiewicz, Kevin M.

    2013-01-01

    Previous research has demonstrated that sport-related concussions can have short-term effects on cognitive processes, but the long-term consequences are less understood and warrant more research. This study was the first to use event-related functional magnetic resonance imaging (fMRI) to examine long-term differences in neural activity during memory tasks in former athletes who have sustained multiple sport-related concussions. In an event-related fMRI study, former football players reportin...

  17. Event-related cortical processing in neuropathic pain under long-term spinal cord stimulation.

    Science.gov (United States)

    Weigel, Ralf; Capelle, H Holger; Flor, Herta; Krauss, Joachim K

    2015-01-01

    Several mechanisms were suggested in the past to explain the beneficial effect of spinal cord stimulation (SCS) in patients suffering from neuropathic pain. Little is known about potential supraspinal mechanisms. In this study cortical signaling of patients with neuropathic pain and successful long-term treatment with SCS was analyzed. Observational study. University hospital, neurosurgical department, outpatient clinic for movement disorders and pain, institute for cognitive and clinical neuroscience. Nine patients with neuropathic pain of a lower extremity with a lasting response to chronic SCS were included. Cortical activity was analyzed using event-related potentials of the electroencephalogram after non-painful and painful stimulation. Each patient was tested under the effect of long-term SCS and 24 hours after cessation of SCS. Cortical areas involved in the peaks of evoked potentials were localized using a source localization method based on a fixed dipole model. Detection threshold and intensity of non-painful stimulation did not differ significantly on both sides. Pain threshold was significantly lower on the neuropathic side under the effect of SCS (P = 0.03). Bilateral pain thresholds were significantly lower (P = 0.03 healthy side, P = 0.003 neuropathic side) in 5 patients with increased pain after cessation of SCS. Under the effect of SCS cortical negativities (N1, N2, N3) and positivities (P1) demonstrated bilaterally comparable amplitudes. After cessation of SCS, decreased threshold for peripheral stimulation resulted in lowered negativities on both sides. The positivity P1 was differentially regulated and was reduced more contralateral to the unaffected side. N2 was localized at the sensory representation of the leg within the homunculus. The main vector of P1 was localized within the cingular cortex (CC) and moved more anteriorly under the effect of SCS. The exact time span that SCS continues to have an effect is not known. However, due to patient

  18. Spatial-Temporal Feature Analysis on Single-Trial Event Related Potential for Rapid Face Identification

    Directory of Open Access Journals (Sweden)

    Lei Jiang

    2017-11-01

    Full Text Available The event-related potential (ERP is the brain response measured in electroencephalography (EEG, which reflects the process of human cognitive activity. ERP has been introduced into brain computer interfaces (BCIs to communicate the computer with the subject's intention. Due to the low signal-to-noise ratio of EEG, most ERP studies are based on grand-averaging over many trials. Recently single-trial ERP detection attracts more attention, which enables real time processing tasks as rapid face identification. All the targets needed to be retrieved may appear only once, and there is no knowledge of target label for averaging. More interestingly, how the features contribute temporally and spatially to single-trial ERP detection has not been fully investigated. In this paper, we propose to implement a local-learning-based (LLB feature extraction method to investigate the importance of spatial-temporal components of ERP in a task of rapid face identification using single-trial detection. Comparing to previous methods, LLB method preserves the nonlinear structure of EEG signal distribution, and analyze the importance of original spatial-temporal components via optimization in feature space. As a data-driven methods, the weighting of the spatial-temporal component does not depend on the ERP detection method. The importance weights are optimized by making the targets more different from non-targets in feature space, and regularization penalty is introduced in optimization for sparse weights. This spatial-temporal feature extraction method is evaluated on the EEG data of 15 participants in performing a face identification task using rapid serial visual presentation paradigm. Comparing with other methods, the proposed spatial-temporal analysis method uses sparser (only 10% of the total features, and could achieve comparable performance (98% of single-trial ERP detection as the whole features across different detection methods. The interesting finding is

  19. Cortical Neural Synchronization Underlies Primary Visual Consciousness of Qualia: Evidence from Event-Related Potentials.

    Science.gov (United States)

    Babiloni, Claudio; Marzano, Nicola; Soricelli, Andrea; Cordone, Susanna; Millán-Calenti, José Carlos; Del Percio, Claudio; Buján, Ana

    2016-01-01

    This article reviews three experiments on event-related potentials (ERPs) testing the hypothesis that primary visual consciousness (stimulus self-report) is related to enhanced cortical neural synchronization as a function of stimulus features. ERP peak latency and sources were compared between "seen" trials and "not seen" trials, respectively related and unrelated to the primary visual consciousness. Three salient features of visual stimuli were considered (visuospatial, emotional face expression, and written words). Results showed the typical visual ERP components in both "seen" and "not seen" trials. There was no statistical difference in the ERP peak latencies between the "seen" and "not seen" trials, suggesting a similar timing of the cortical neural synchronization regardless the primary visual consciousness. In contrast, ERP sources showed differences between "seen" and "not seen" trials. For the visuospatial stimuli, the primary consciousness was related to higher activity in dorsal occipital and parietal sources at about 400 ms post-stimulus. For the emotional face expressions, there was greater activity in parietal and frontal sources at about 180 ms post-stimulus. For the written letters, there was higher activity in occipital, parietal and temporal sources at about 230 ms post-stimulus. These results hint that primary visual consciousness is associated with an enhanced cortical neural synchronization having entirely different spatiotemporal characteristics as a function of the features of the visual stimuli and possibly, the relative qualia (i.e., visuospatial, face expression, and words). In this framework, the dorsal visual stream may be synchronized in association with the primary consciousness of visuospatial and emotional face contents. Analogously, both dorsal and ventral visual streams may be synchronized in association with the primary consciousness of linguistic contents. In this line of reasoning, the ensemble of the cortical neural networks

  20. Synthetic event-related potentials: a computational bridge between neurolinguistic models and experiments.

    Science.gov (United States)

    Barrès, Victor; Simons, Arthur; Arbib, Michael

    2013-01-01

    Our previous work developed Synthetic Brain Imaging to link neural and schema network models of cognition and behavior to PET and fMRI studies of brain function. We here extend this approach to Synthetic Event-Related Potentials (Synthetic ERP). Although the method is of general applicability, we focus on ERP correlates of language processing in the human brain. The method has two components: Phase 1: To generate cortical electro-magnetic source activity from neural or schema network models; and Phase 2: To generate known neurolinguistic ERP data (ERP scalp voltage topographies and waveforms) from putative cortical source distributions and activities within a realistic anatomical model of the human brain and head. To illustrate the challenges of Phase 2 of the methodology, spatiotemporal information from Friederici's 2002 model of auditory language comprehension was used to define cortical regions and time courses of activation for implementation within a forward model of ERP data. The cortical regions from the 2002 model were modeled using atlas-based masks overlaid on the MNI high definition single subject cortical mesh. The electromagnetic contribution of each region was modeled using current dipoles whose position and orientation were constrained by the cortical geometry. In linking neural network computation via EEG forward modeling to empirical results in neurolinguistics, we emphasize the need for neural network models to link their architecture to geometrically sound models of the cortical surface, and the need for conceptual models to refine and adopt brain-atlas based approaches to allow precise brain anchoring of their modules. The detailed analysis of Phase 2 sets the stage for a brief introduction to Phase 1 of the program, including the case for a schema-theoretic approach to language production and perception presented in detail elsewhere. Unlike Dynamic Causal Modeling (DCM) and Bojak's mean field model, Synthetic ERP builds on models of networks

  1. Event Related Potential Study of Language Interaction in Bilingual Aphasia Patients.

    Science.gov (United States)

    Khachatryan, Elvira; Wittevrongel, Benjamin; De Keyser, Kim; De Letter, Miet; Hulle, Marc M Van

    2018-01-01

    Half of the global population can be considered bilingual. Nevertheless when faced with patients with aphasia, clinicians and therapists usually ignore the patient's second language (L2) albeit its interference in first language (L1) processing has been shown. The excellent temporal resolution by which each individual linguistic component can be gaged during word-processing, promoted the event-related potential (ERP) technique for studying language processing in healthy bilinguals and monolingual aphasia patients. However, this technique has not yet been applied in the context of bilingual aphasia. In the current study, we report on L2 interference in L1 processing using the ERP technique in bilingual aphasia. We tested four bilingual- and one trilingual patients with aphasia, as well as several young and older (age-matched with patients) healthy subjects as controls. We recorded ERPs when subjects were engaged in a semantic association judgment task on 122 related and 122 unrelated Dutch word-pairs (prime and target words). In 61 related and 61 unrelated word-pairs, an inter-lingual homograph was used as prime. In these word-pairs, when the target was unrelated to the prime in Dutch (L1), it was associated to the English (L2) meaning of the homograph. Results showed a significant effect of homograph use as a prime on early and/or late ERPs in response to word-pairs related in Dutch or English. Each patient presented a unique pattern of L2 interference in L1 processing as reflected by his/her ERP image. These interferences depended on the patient's pre- and post-morbid L2 proficiency. When the proficiency was high, the L2 interference in L1 processing was higher. Furthermore, the mechanism of interference in patients that were pre-morbidly highly proficient in L2 additionally depended on the frequency of pre-morbid L2 exposure. In summary, we showed that the mechanism behind L2 interference in L1 processing in bilingual patients with aphasia depends on a complex

  2. Event-related potentials as a measure of sleep disturbance: A tutorial review

    Directory of Open Access Journals (Sweden)

    Kenneth Campbell

    2010-01-01

    Full Text Available This article reviews event-related potentials (ERPs the minute responses of the human brain that are elicited by external auditory stimuli and how the ERPs can be used to measure sleep disturbance. ERPs consist of a series of negative- and positive-going components. A negative component peaking at about 100 ms, N1, is thought to reflect the outcome of a transient detector system, activated by change in the transient energy in an acoustic stimulus. Its output and thus the amplitude of N1 increases as the intensity level of the stimulus is increased and when the rate of presentation is slowed. When the output reaches a certain critical level, operations of the central executive are interrupted and attention is switched to the auditory channel. This switching of attention is thought to be indexed by a later positivity, P3a, peaking between 250 and 300 ms. In order to sleep, consciousness for all but the most relevant of stimuli must be prevented. Thus, during sleep onset and definitive non-rapid eye movement (NREM sleep, the amplitude of N1 diminishes to near-baseline level. The amplitude of P2, peaking from 180 to 200 ms, is however larger in NREM sleep than in wakefulness. P2 is thought to reflect an inhibitory process protecting sleep from irrelevant disturbance. As stimulus input becomes increasingly obtrusive, the amplitude of P2 also increases. With increasing obtrusiveness particularly when stimuli are presented slowly, a later large negativity, peaking at about 350 ms, N350, becomes apparent. N350 is unique to sleep, its amplitude also increasing as the stimulus becomes more obtrusive. Many authors postulate that when the N350 reaches a critical amplitude, a very large amplitude N550, a component of the K-Complex is elicited. The K-Complex can only be elicited during NREM sleep. The P2, N350 and N550 processes are thus conceived as sleep protective mechanisms, activated sequentially as the risk for disturbance increases. During REM sleep

  3. Hemispheric asymmetry in interpreting novel literal language: an event-related potential study.

    Science.gov (United States)

    Davenport, Tristan; Coulson, Seana

    2013-04-01

    Conceptual mapping, or making connections between conceptual structure in different domains, is a key mechanism of creative language use whose neural underpinnings are not well understood. The present study involved the combination of event-related potentials (ERPs) with the divided visual field presentation technique to explore the relative contributions of the left and right hemispheres (LH and RH) to the construction of novel meanings in fully literal language. Electroencephalogram (EEG) was recorded as healthy adults read sentences that supported either a conventional literal reading of the sentence final word ("His main method of transportation is a boat,"), or a novel literal meaning derived from conceptual mapping ("The clever boys used a cardboard box as a boat,"). The novel and conventional conditions were matched for cloze probability (a measure of predictability based on the sentence context), lexical association between the sentence frame and the final word (using latent semantic analysis), and other factors known to influence ERPs to language stimuli. To compare effects of novelty to previously reported effects of predictability, a high-cloze conventional condition ("The only way to get around Venice is to navigate the canals in a boat.") was included. ERPs were time-locked to sentence final words ("boat") presented in either the left visual field, to preferentially stimulate the RH (lvf/RH), or in the right visual field, targeting the LH (rvf/LH). The N400 component of the ERP was affected by predictability in both presentation sides, but by novelty only in rvf/LH. Two distinct late frontal positive effects were observed. Word predictability modulated a frontal positivity with a LH focus, but semantic novelty modulated a frontal positivity focused in RH. This is the first demonstration that the frontal positivity may be composed of multiple overlapping components with distinct functional and anatomical characteristics. Extending contemporary accounts

  4. Markov Switching Model for Quick Detection of Event Related Desynchronization in EEG

    Directory of Open Access Journals (Sweden)

    Giuseppe Lisi

    2018-02-01

    Full Text Available Quick detection of motor intentions is critical in order to minimize the time required to activate a neuroprosthesis. We propose a Markov Switching Model (MSM to achieve quick detection of an event related desynchronization (ERD elicited by motor imagery (MI and recorded by electroencephalography (EEG. Conventional brain computer interfaces (BCI rely on sliding window classifiers in order to perform online continuous classification of the rest vs. MI classes. Based on this approach, the detection of abrupt changes in the sensorimotor power suffers from an intrinsic delay caused by the necessity of computing an estimate of variance across several tenths of a second. Here we propose to avoid explicitly computing the EEG signal variance, and estimate the ERD state directly from the voltage information, in order to reduce the detection latency. This is achieved by using a model suitable in situations characterized by abrupt changes of state, the MSM. In our implementation, the model takes the form of a Gaussian observation model whose variance is governed by two latent discrete states with Markovian dynamics. Its objective is to estimate the brain state (i.e., rest vs. ERD given the EEG voltage, spatially filtered by common spatial pattern (CSP, as observation. The two variances associated with the two latent states are calibrated using the variance of the CSP projection during rest and MI, respectively. The transition matrix of the latent states is optimized by the “quickest detection” strategy that minimizes a cost function of detection latency and false positive rate. Data collected by a dry EEG system from 50 healthy subjects, was used to assess performance and compare the MSM with several logistic regression classifiers of different sliding window lengths. As a result, the MSM achieves a significantly better tradeoff between latency, false positive and true positive rates. The proposed model could be used to achieve a more reactive and

  5. The development of prospective memory (PM across adolescence: An Event-related potential analysis.

    Directory of Open Access Journals (Sweden)

    Candice eBowman

    2015-06-01

    Full Text Available Prospective memory (PM is an important cognitive function vital for day-to-day functioning. Although there has been extensive research into the decline of PM in older adulthood, little is known about its developmental trajectory throughout adolescence, a time of important brain maturation. In the present study, the development of PM was examined in 85 participants across the following groups: 12 to 13-year-olds (n = 19, 14 to 15-year-olds (n = 21, 16 to 17-year-olds (n = 19, and 18 to 19-year-olds (n = 26. A 30-cue (30 minute event-based PM task (with font-colour stimuli as PM cues and a lexical-decision task as the ongoing task was used while recording Event-Related Potentials (ERPs. The well-established neural correlates of PM, the N300 and parietal positivity, were examined across the age groups. In addition, hierarchical multiple regressions were used to examine the unique contribution of executive functioning measures (viz., the Self-Ordered Pointing Task [SOPT], the Stroop task, and Trail Making Test [TMT] on the ERP components of PM (after controlling for age. First, the established components of ERPs associated with prospective remembering (i.e., N300 and parietal positivity were detected for each age group. Second, although there were no significant age- group differences on the amplitude of the N300, the amplitude of the parietal positivity was found to be different between the 12 to 13-year-olds and 18 to 19-year-olds (viz., the 12 to 13-year-olds had the highest amplitude. Third, for the contribution of executive functioning measures on the amplitude of the ERP components of PM, the regression on the N300 was not significant, however, the SOPT beta weights were significant predictors of the amplitude of the parietal positivity. This relationship was found to be specific for the central and right electrode region. These findings are discussed within the context of brain development and executive functioning along with particular task

  6. Evaluation of auditory perception development in neonates by quantitative electroencephalography and auditory event-related potentials.

    Science.gov (United States)

    Zhang, Qinfen; Cheng, Qirui; Li, Hongxin; Dong, Xuan; Tu, Wenjuan

    2017-01-01

    The present study was performed to investigate neonatal auditory perception function by quantitative electroencephalography (QEEG) and auditory event-related potentials (aERPs) and identify the characteristics of auditory perception development in newborns. Fifty-three normal full-term neonates were divided into three groups according their age in days. An auditory oddball paradigm was used. QEEG (resting state and task state) and aERPs were performed. EEG δ power in the resting and task states and at different ages was respectively analyzed. The N2 area and latency of aERPs at different ages were also compared. The four main findings of this study are as follows. First, the increase in the EEG δ power was significantly greater in the task than resting state in Group 3 at the Fz lead (t = -3.371, P = 0.004) and in Groups 2 and 3 at the Cz lead (Group 2: t = -3.149, P = 0.005; Group 3: t = -3.609, P = 0.002). Second, the δ power gradually increased from 1 to 10 days of age (Group 1), peaked at 11 to 20 days (Group 2), and gradually decreased from 21 to 28 days (Group 3). The data in the Fz lead during the task state and in the Cz lead during the resting and task states were statistically significant (F = 5.875, P = 0.005; F = 5.523, P = 0.007; and F = 5.402, P = 0.008, respectively). Third, the N2 area significantly increased with age by presentation of target stimuli (F = 5.26, P = 0.01). The N2 area increased most significantly from 21 to 28 days (Group 3). Finally, the N2 latency significantly decreased with age (Fz lead: F = 4.66, P = 0.023; Cz lead: F = 7.18, P = 0.005). The N2 latency decreased most significantly from 11 to 20 days of age (Group 2). Rapid cognitive development occurs during the neonatal period. In the first several days after birth, the EEG δ power and N2 area manifested the characteristic performance of identifying task information. QEEG and aERP measurement can be used as objective indices with which to evaluate auditory perception

  7. Evaluation of auditory perception development in neonates by quantitative electroencephalography and auditory event-related potentials.

    Directory of Open Access Journals (Sweden)

    Qinfen Zhang

    Full Text Available The present study was performed to investigate neonatal auditory perception function by quantitative electroencephalography (QEEG and auditory event-related potentials (aERPs and identify the characteristics of auditory perception development in newborns.Fifty-three normal full-term neonates were divided into three groups according their age in days. An auditory oddball paradigm was used. QEEG (resting state and task state and aERPs were performed. EEG δ power in the resting and task states and at different ages was respectively analyzed. The N2 area and latency of aERPs at different ages were also compared.The four main findings of this study are as follows. First, the increase in the EEG δ power was significantly greater in the task than resting state in Group 3 at the Fz lead (t = -3.371, P = 0.004 and in Groups 2 and 3 at the Cz lead (Group 2: t = -3.149, P = 0.005; Group 3: t = -3.609, P = 0.002. Second, the δ power gradually increased from 1 to 10 days of age (Group 1, peaked at 11 to 20 days (Group 2, and gradually decreased from 21 to 28 days (Group 3. The data in the Fz lead during the task state and in the Cz lead during the resting and task states were statistically significant (F = 5.875, P = 0.005; F = 5.523, P = 0.007; and F = 5.402, P = 0.008, respectively. Third, the N2 area significantly increased with age by presentation of target stimuli (F = 5.26, P = 0.01. The N2 area increased most significantly from 21 to 28 days (Group 3. Finally, the N2 latency significantly decreased with age (Fz lead: F = 4.66, P = 0.023; Cz lead: F = 7.18, P = 0.005. The N2 latency decreased most significantly from 11 to 20 days of age (Group 2.Rapid cognitive development occurs during the neonatal period. In the first several days after birth, the EEG δ power and N2 area manifested the characteristic performance of identifying task information. QEEG and aERP measurement can be used as objective indices with which to evaluate auditory perception

  8. Spatial attention facilitates selection of illusory objects: evidence from event-related brain potentials.

    Science.gov (United States)

    Martínez, Antígona; Teder-Salejarvi, Wolfgang; Hillyard, Steven A

    2007-03-30

    The relationship between spatial attention and object-based attention has long been debated. On the basis of behavioral evidence it has been hypothesized that these two forms of attention share a common mechanism, such that directing spatial attention to one part of an object facilitates the selection of the entire object. In a previous study (Martinez, A., Teder-Salejarvi, W., Vazquez, M., Molholm, S., Foxe, J.J., Javitt, D.C., Di Russo, F., Worden, M.S., Hillyard, S.A., 2006. "Objects are highlighted by spatial attention." J. Cogn. Neurosci. 18(2): 298-310) we used recordings of event-related potentials (ERPs) during a paradigm modeled after that of Egly et al. (Egly, R., Driver, J., Rafal, D.R., 1994. Shifting visual attention between objects and locations: evidence from normal and parietal lesion subjects. J. Exp. Psychol. Gen. 123(2) 161-77) to investigate this relationship. As reported in numerous studies of spatial attention, we found the typical pattern of enhanced neural activity in visual cortex elicited by attended stimuli. Unattended stimuli belonging to the same object as the attended stimuli elicited a very similar spatiotemporal pattern of enhanced neural activity that was localized to lateral occipital cortex (LOC). This similarity was taken as evidence that spatial- and object-selective attention share, at least in part, a common neural mechanism. In the present study we further investigate this relationship by examining whether this spread of spatial attention within attended objects can be guided by objects defined by illusory contours. Subjects viewed a display consisting of two illusory rectangular objects and directed attention to continuous sequences of stimuli (brief onsets) at one end of one of the objects. Stimuli occurring at irrelevant locations but belonging to the same attended object elicited larger posterior N1 amplitudes than that elicited by unattended objects forming part of a different object. This object-selective N1 enhancement

  9. Verbal Learning and Memory in Cannabis and Alcohol Users: An Event-Related Potential Investigation.

    Science.gov (United States)

    Smith, Janette L; De Blasio, Frances M; Iredale, Jaimi M; Matthews, Allison J; Bruno, Raimondo; Dwyer, Michelle; Batt, Tessa; Fox, Allison M; Solowij, Nadia; Mattick, Richard P

    2017-01-01

    Aims: Long-term heavy use of cannabis and alcohol are known to be associated with memory impairments. In this study, we used event-related potentials to examine verbal learning and memory processing in a commonly used behavioral task. Method: We conducted two studies: first, a small pilot study of adolescent males, comprising 13 Drug-Naive Controls (DNC), 12 heavy drinkers (HD) and 8 cannabis users (CU). Second, a larger study of young adults, comprising 45 DNC (20 female), 39 HD (16 female), and 20 CU (9 female). In both studies, participants completed a modified verbal learning task (the Rey Auditory Verbal Learning Test, RAVLT) while brain electrical activity was recorded. ERPs were calculated for words which were subsequently remembered vs. those which were not remembered, and for presentations of learnt words, previously seen words, and new words in a subsequent recognition test. Pre-planned principal components analyses (PCA) were used to quantify the ERP components in these recall and recognition phases separately for each study. Results: Memory performance overall was slightly lower than published norms using the standardized RAVLT delivery, but was generally similar and showed the expected changes over trials. Few differences in performance were observed between groups; a notable exception was markedly poorer delayed recall in HD relative to DNC (Study 2). PCA identified components expected from prior research using other memory tasks. At encoding, there were no between-group differences in the usual P2 recall effect (larger for recalled than not-recalled words). However, alcohol-related differences were observed in a larger P540 (indexing recollection) in HD than DNC, and cannabis-related differences were observed in a smaller N340 (indexing familiarity) and a lack of previously seen > new words effect for P540 in Study 2. Conclusions: This study is the first examination of ERPs in the RAVLT in healthy control participants, as well as substance

  10. Verbal Learning and Memory in Cannabis and Alcohol Users: An Event-Related Potential Investigation

    Directory of Open Access Journals (Sweden)

    Janette L. Smith

    2017-12-01

    Full Text Available Aims: Long-term heavy use of cannabis and alcohol are known to be associated with memory impairments. In this study, we used event-related potentials to examine verbal learning and memory processing in a commonly used behavioral task.Method: We conducted two studies: first, a small pilot study of adolescent males, comprising 13 Drug-Naive Controls (DNC, 12 heavy drinkers (HD and 8 cannabis users (CU. Second, a larger study of young adults, comprising 45 DNC (20 female, 39 HD (16 female, and 20 CU (9 female. In both studies, participants completed a modified verbal learning task (the Rey Auditory Verbal Learning Test, RAVLT while brain electrical activity was recorded. ERPs were calculated for words which were subsequently remembered vs. those which were not remembered, and for presentations of learnt words, previously seen words, and new words in a subsequent recognition test. Pre-planned principal components analyses (PCA were used to quantify the ERP components in these recall and recognition phases separately for each study.Results: Memory performance overall was slightly lower than published norms using the standardized RAVLT delivery, but was generally similar and showed the expected changes over trials. Few differences in performance were observed between groups; a notable exception was markedly poorer delayed recall in HD relative to DNC (Study 2. PCA identified components expected from prior research using other memory tasks. At encoding, there were no between-group differences in the usual P2 recall effect (larger for recalled than not-recalled words. However, alcohol-related differences were observed in a larger P540 (indexing recollection in HD than DNC, and cannabis-related differences were observed in a smaller N340 (indexing familiarity and a lack of previously seen > new words effect for P540 in Study 2.Conclusions: This study is the first examination of ERPs in the RAVLT in healthy control participants, as well as substance

  11. Event-Related Potential Measures of Attention Capture in Adolescent Inpatients With Acute Suicidal Behavior

    Directory of Open Access Journals (Sweden)

    Paniz Tavakoli

    2018-03-01

    Full Text Available Impaired executive functions, modulated by the frontal lobes, have been suggested to be associated with suicidal behavior. The present study examines one of these executive functions, attentional control, maintaining attention to the task-at-hand. A group of inpatient adolescents with acute suicidal behavior and healthy controls were studied using a passively presented auditory optimal paradigm. This “optimal” paradigm consisted of a series of frequently presented homogenous pure tone “standards” and different “deviants,” constructed by changing one or more features of the standard. The optimal paradigm has been shown to be a more time-efficient replacement to the traditional oddball paradigm, which makes it suitable for use in clinical populations. The extent of processing of these “to-be-ignored” auditory stimuli was measured by recording event-related potentials (ERPs. The P3a ERP component is thought to reflect processes associated with the capturing of attention. Rare and novel stimuli may result in an executive decision to switch attention away from the current cognitive task and toward a probe of the potentially more relevant “interrupting” auditory input. On the other hand, stimuli that are quite similar to the standard should not elicit P3a. The P3a has been shown to be larger in immature brains in early compared to later adolescence. An overall enhanced P3a was observed in the suicidal group. The P3a was larger in this group for both the environmental sound and white noise deviants, although only the environmental sound P3a attained significance. Other deviants representing only a small change from the standard did not elicit a P3a in healthy controls. They did elicit a small P3a in the suicidal group. These findings suggest a lowered threshold for the triggering of the involuntary switch of attention in these patients, which may play a role in their reported distractibility. The enhanced P3a is also suggestive of

  12. Uncertainty quantification in volumetric Particle Image Velocimetry

    Science.gov (United States)

    Bhattacharya, Sayantan; Charonko, John; Vlachos, Pavlos

    2016-11-01

    Particle Image Velocimetry (PIV) uncertainty quantification is challenging due to coupled sources of elemental uncertainty and complex data reduction procedures in the measurement chain. Recent developments in this field have led to uncertainty estimation methods for planar PIV. However, no framework exists for three-dimensional volumetric PIV. In volumetric PIV the measurement uncertainty is a function of reconstructed three-dimensional particle location that in turn is very sensitive to the accuracy of the calibration mapping function. Furthermore, the iterative correction to the camera mapping function using triangulated particle locations in space (volumetric self-calibration) has its own associated uncertainty due to image noise and ghost particle reconstructions. Here we first quantify the uncertainty in the triangulated particle position which is a function of particle detection and mapping function uncertainty. The location uncertainty is then combined with the three-dimensional cross-correlation uncertainty that is estimated as an extension of the 2D PIV uncertainty framework. Finally the overall measurement uncertainty is quantified using an uncertainty propagation equation. The framework is tested with both simulated and experimental cases. For the simulated cases the variation of estimated uncertainty with the elemental volumetric PIV error sources are also evaluated. The results show reasonable prediction of standard uncertainty with good coverage.

  13. Green chemistry volumetric titration kit for pharmaceutical ...

    African Journals Online (AJOL)

    Stopcock SC and Spring Sp models of Econoburette (Calibrated, RTC (NR), Ministry of Small Scale Industries, Government of India), developed for semimicro volumetric titration of pharmaceutical formulations are reported. These are economized and risk free titration where pipette is replaced by an inbuilt pipette and ...

  14. Volumetric, dashboard-mounted augmented display

    Science.gov (United States)

    Kessler, David; Grabowski, Christopher

    2017-11-01

    The optical design of a compact volumetric display for drivers is presented. The system displays a true volume image with realistic physical depth cues, such as focal accommodation, parallax and convergence. A large eyebox is achieved with a pupil expander. The windshield is used as the augmented reality combiner. A freeform windshield corrector is placed at the dashboard.

  15. Effect of Mood States on the Breadth of Spatial Attentional Focus: An Event-Related Potential Study

    Science.gov (United States)

    Moriya, Hiroki; Nittono, Hiroshi

    2011-01-01

    In order to determine the processing stage that is responsible for the effect of mood states on the breadth of attentional focus, we recorded event-related potentials from 18 students who performed a flanker task involving adjacent letters. To induce a specific mood state, positive, neutral, or negative affective pictures were presented repeatedly…

  16. Attenuated Auditory Event-Related Potentials and Associations with Atypical Sensory Response Patterns in Children with Autism

    Science.gov (United States)

    Donkers, Franc C. L.; Schipul, Sarah E.; Baranek, Grace T.; Cleary, Katherine M.; Willoughby, Michael T.; Evans, Anna M.; Bulluck, John C.; Lovmo, Jeanne E.; Belger, Aysenil

    2015-01-01

    Neurobiological underpinnings of unusual sensory features in individuals with autism are unknown. Event-related potentials elicited by task-irrelevant sounds were used to elucidate neural correlates of auditory processing and associations with three common sensory response patterns (hyperresponsiveness; hyporesponsiveness; sensory seeking).…

  17. Perceiving temporal regularity in music: The role of auditory event-related potentials (ERPs) in probing beat perception

    NARCIS (Netherlands)

    Honing, H.; Bouwer, F.L.; Háden, G.P.; Merchant, H.; de Lafuente, V.

    2014-01-01

    The aim of this chapter is to give an overview of how the perception of a regular beat in music can be studied in humans adults, human newborns, and nonhuman primates using event-related brain potentials (ERPs). Next to a review of the recent literature on the perception of temporal regularity in

  18. Does Silent Reading Speed in Normal Adult Readers Depend on Early Visual Processes? Evidence from Event-Related Brain Potentials

    Science.gov (United States)

    Korinth, Sebastian Peter; Sommer, Werner; Breznitz, Zvia

    2012-01-01

    Little is known about the relationship of reading speed and early visual processes in normal readers. Here we examined the association of the early P1, N170 and late N1 component in visual event-related potentials (ERPs) with silent reading speed and a number of additional cognitive skills in a sample of 52 adult German readers utilizing a Lexical…

  19. Newborn Event-Related Potentials Predict Poorer Pre-Reading Skills in Children at Risk for Dyslexia

    Science.gov (United States)

    Guttorm, Tomi K.; Leppanen, Paavo H. T.; Hamalainen, Jarmo A.; Eklund, Kenneth M.; Lyytinen, Heikki J.

    2010-01-01

    Earlier results from the Jyvaskyla Longitudinal Study of Dyslexia showed that newborn event-related potentials (ERPs) of children with and without familial risk for dyslexia were associated with receptive language and verbal memory skills between 2.5 and 5 years of age. We further examined whether these ERPs (responses to synthetic consonant-vowel…

  20. An event-related brain potential study of visual selective attention to conjunctions of color and shape

    NARCIS (Netherlands)

    Smid, HGOM; Jakob, A; Heinze, HJ

    What cognitive processes underlie event-related brain potential (ERP) effects related to visual multidimensional selective attention and how are these processes organized? We recorded ERPs when participants attended to one conjunction of color, global shape and local shape and ignored other

  1. Exploring the activation of semantic and phonological codes during speech planning with event-related brain potentials

    NARCIS (Netherlands)

    Jescheniak, J.D.; Schriefers, H.J.; Garrett, M.F.; Friederici, A.D.

    2002-01-01

    We present a new technique for studying the activation of semantic and phonological codes in speech planning using event-related brain potentials (ERPs) that extend a well-established behavioral procedure from speech production research. It combines a delayed picture-naming task with a priming

  2. Does erotic stimulus presentation design affect brain activation patterns? Event-related vs. blocked fMRI designs

    Directory of Open Access Journals (Sweden)

    Klemen Jane

    2008-07-01

    Full Text Available Abstract Background Existing brain imaging studies, investigating sexual arousal via the presentation of erotic pictures or film excerpts, have mainly used blocked designs with long stimulus presentation times. Methods To clarify how experimental functional magnetic resonance imaging (fMRI design affects stimulus-induced brain activity, we compared brief event-related presentation of erotic vs. neutral stimuli with blocked presentation in 10 male volunteers. Results Brain activation differed depending on design type in only 10% of the voxels showing task related brain activity. Differences between blocked and event-related stimulus presentation were found in occipitotemporal and temporal regions (Brodmann Area (BA 19, 37, 48, parietal areas (BA 7, 40 and areas in the frontal lobe (BA 6, 44. Conclusion Our results suggest that event-related designs might be a potential alternative when the core interest is the detection of networks associated with immediate processing of erotic stimuli. Additionally, blocked, compared to event-related, stimulus presentation allows the emergence and detection of non-specific secondary processes, such as sustained attention, motor imagery and inhibition of sexual arousal.

  3. A framework combining delta Event-Related Oscillations (EROs) and Synchronisation Effects (ERD/ERS) to study emotional processing.

    Science.gov (United States)

    Klados, Manousos A; Frantzidis, Christos; Vivas, Ana B; Papadelis, Christos; Lithari, Chrysa; Pappas, Costas; Bamidis, Panagiotis D

    2009-01-01

    Event-Related Potentials (ERPs) or Event-Related Oscillations (EROs) have been widely used to study emotional processing, mainly on the theta and gamma frequency bands. However, the role of the slow (delta) waves has been largely ignored. The aim of this study is to provide a framework that combines EROs with Event-Related Desynchronization (ERD)/Event-Related Synchronization (ERS), and peak amplitude analysis of delta activity, evoked by the passive viewing of emotionally evocative pictures. Results showed that this kind of approach is sensitive to the effects of gender, valence, and arousal, as well as, the study of interhemispherical disparity, as the two-brain hemispheres interplay roles in the detailed discrimination of gender. Valence effects are recovered in both the central electrodes as well as in the hemisphere interactions. These findings suggest that the temporal patterns of delta activity and the alterations of delta energy may contribute to the study of emotional processing. Finally the results depict the improved sensitivity of the proposed framework in comparison to the traditional ERP techniques, thereby delineating the need for further development of new methodologies to study slow brain frequencies.

  4. The Role of Episodic Memory in Controlled Evaluative Judgments about Attitudes: An Event-Related Potential Study

    Science.gov (United States)

    Johnson, Ray, Jr.; Simon, Elizabeth J.; Henkell, Heather; Zhu, John

    2011-01-01

    Event-related potentials (ERPs) are unique in their ability to provide information about the timing of activity in the neural networks that perform complex cognitive processes. Given the dearth of extant data from normal controls on the question of whether attitude representations are stored in episodic or semantic memory, the goal here was to…

  5. Infant Attention and Visual Preferences: Converging Evidence from Behavior, Event-Related Potentials, and Cortical Source Localization

    Science.gov (United States)

    Reynolds, Greg D.; Courage, Mary L.; Richards, John E.

    2010-01-01

    In this study, we had 3 major goals. The 1st goal was to establish a link between behavioral and event-related potential (ERP) measures of infant attention and recognition memory. To assess the distribution of infant visual preferences throughout ERP testing, we designed a new experimental procedure that embeds a behavioral measure (paired…

  6. Tracking the Time Course of Word-Frequency Effects in Auditory Word Recognition with Event-Related Potentials

    Science.gov (United States)

    Dufour, Sophie; Brunelliere, Angele; Frauenfelder, Ulrich H.

    2013-01-01

    Although the word-frequency effect is one of the most established findings in spoken-word recognition, the precise processing locus of this effect is still a topic of debate. In this study, we used event-related potentials (ERPs) to track the time course of the word-frequency effect. In addition, the neighborhood density effect, which is known to…

  7. An Event-Related Potential (ERP) Investigation of Filler-Gap Processing in Native and Second Language Speakers

    Science.gov (United States)

    Dallas, Andrea; DeDe, Gayle; Nicol, Janet

    2013-01-01

    The current study employed a neuro-imaging technique, Event-Related Potentials (ERP), to investigate real-time processing of sentences containing filler-gap dependencies by late-learning speakers of English as a second language (L2) with a Chinese native language background. An individual differences approach was also taken to examine the role of…

  8. Parahippocampal activation during successful recognition of words: a self-paced event-related fMRI study

    NARCIS (Netherlands)

    Daselaar, S. M.; Rombouts, S. A.; Veltman, D. J.; Raaijmakers, J. G.; Lazeron, R. H.; Jonker, C.

    2001-01-01

    In this study, we investigated retrieval from verbal episodic memory using a self-paced event-related fMRI paradigm, similar to the designs typically used in behavioral studies of memory function. We tested the hypothesis that the medial temporal lobe (MTL) is involved in the actual recovery of

  9. Identical event-related potentials to target and frequent stimuli of visual oddball task recorded by intracerebral electrodes

    Czech Academy of Sciences Publication Activity Database

    Kukleta, M.; Brázdil, M.; Roman, R.; Jurák, Pavel

    2003-01-01

    Roč. 114, č. 7 (2003), s. 1292 - 1297 ISSN 1388-2457 Institutional research plan: CEZ:AV0Z2065902 Keywords : event-related potential * intra-cerebral EEG recording in humans * oddball task Subject RIV: FA - Cardiovascular Diseases incl. Cardiotharic Surgery Impact factor: 2.485, year: 2003

  10. Classification of Event-Related Potentials Associated with Response Errors in Actors and Observers Based on Autoregressive Modeling

    NARCIS (Netherlands)

    Vasios, C.E.; Ventouras, E.M.; Matsopoulos, G.K.; Karanasiou, I.; Asvestas, P.; Uzunoglu, N.K.; Schie, H.T. van; Bruijn, E.R.A. de

    2009-01-01

    Event-Related Potentials (ERPs) provide non-invasive measurements of the electrical activity on the scalp related to the processing of stimuli and preparation of responses by the brain. In this paper an ERP-signal classification method is proposed for discriminating between ERPs of correct and

  11. Pre-Attentive Mental Processing of Music Expectation: Event-Related Potentials of a Partially Violating and Resolving Paradigm

    Science.gov (United States)

    Pei, Yu-Cheng; Chen, Chia-Ling; Chung, Chia-Ying; Chou, Shi-Wei; Wong, Alice M. K.; Tang, Simon F. T.

    2004-01-01

    Auditory event-related potentials (ERPs) were investigated in an oddball paradigm to verify electrophysiological evidence of music expectation, which is a key component of artistic presentation. The non-target condition consisted of four-chord harmonic chord sequences, while the target condition was manifested by a partially violating third chord…

  12. Internal consistency of event-related potentials associated with cognitive control: N2/P3 and ERN/Pe

    NARCIS (Netherlands)

    W.J.R. Rietdijk (Wim); I.H.A. Franken (Ingmar); A.R. Thurik (Roy)

    2014-01-01

    textabstractRecent studies in psychophysiology show an increased attention for examining the reliability of Event-Related Potentials (ERPs), which are measures of cognitive control (e.g., Go/No-Go tasks). An important index of reliability is the internal consistency (e.g., Cronbach's alpha) of a

  13. A comparison of event-related potential of humans and rats elicited by a serial feature-positive discrimination task

    NARCIS (Netherlands)

    Sambeth, A.; Maes, J.H.R.

    2006-01-01

    The purpose of this experiment was to compare components of the human and rat auditory event-related potential (ERP) in a serial feature-positive discrimination task. Subjects learned to respond to an auditory target stimulus when it followed a visual feature (X→A+), but to not respond when it was

  14. Auto-adaptive averaging: Detecting artifacts in event-related potential data using a fully automated procedure

    NARCIS (Netherlands)

    Talsma, D.

    2008-01-01

    The auto-adaptive averaging procedure proposed here classifies artifacts in event-related potential data by optimizing the signal-to-noise ratio. This method rank orders single trials according to the impact of each trial on the ERP average. Then, the minimum residual background noise level in the

  15. Auto-adaptive averaging: Detecting artifacts in event-related potential data using a fully automated procedure.

    NARCIS (Netherlands)

    Talsma, D.

    2008-01-01

    The auto-adaptive averaging procedure proposed here classifies artifacts in event-related potential data by optimizing the signal-to-noise ratio. This method rank orders single trials according to the impact of each trial on the ERP average. Then, the minimum residual background noise level in the

  16. A Framework Combining Delta Event-Related Oscillations (EROs and Synchronisation Effects (ERD/ERS to Study Emotional Processing

    Directory of Open Access Journals (Sweden)

    Manousos A. Klados

    2009-01-01

    Full Text Available Event-Related Potentials (ERPs or Event-Related Oscillations (EROs have been widely used to study emotional processing, mainly on the theta and gamma frequency bands. However, the role of the slow (delta waves has been largely ignored. The aim of this study is to provide a framework that combines EROs with Event-Related Desynchronization (ERD/Event-Related Synchronization (ERS, and peak amplitude analysis of delta activity, evoked by the passive viewing of emotionally evocative pictures. Results showed that this kind of approach is sensitive to the effects of gender, valence, and arousal, as well as, the study of interhemispherical disparity, as the two-brain hemispheres interplay roles in the detailed discrimination of gender. Valence effects are recovered in both the central electrodes as well as in the hemisphere interactions. These findings suggest that the temporal patterns of delta activity and the alterations of delta energy may contribute to the study of emotional processing. Finally the results depict the improved sensitivity of the proposed framework in comparison to the traditional ERP techniques, thereby delineating the need for further development of new methodologies to study slow brain frequencies.

  17. An fNIRS investigation of associative recognition in the prefrontal cortex with a rapid event-related design.

    Science.gov (United States)

    Schaeffer, James D; Yennu, Amarnath S; Gandy, Kellen C; Tian, Fenghua; Liu, Hanli; Park, Heekyeong

    2014-09-30

    Functional near-infrared spectroscopy (fNIRS) measures hemodynamic changes at the cortical level. The use of fNIRS is growing in popularity for studying cognitive neuroscience in which event-related designs are widely used with functional magnetic resonance imaging (fMRI). However, the applicability of event-related designs with fNIRS has not been fully understood. Therefore, the present study employed fNIRS with a rapid-presentation event-related design for investigating prefrontal cortical activity during complex associative recognition. Participants studied a list of word pairs and were later given an associative recognition test. Throughout the experiment, each event was presented rapidly (∼4s). Data were sorted based on accuracy of associative memory judgments and analyzed using the general linear model (GLM) with an event-related design. During retrieval, significant increases in oxygenated hemoglobin concentrations were observed in dorsolateral and ventrolateral prefrontal regions for successful associative recognition. When comparing retrieval to encoding, significant increases in oxygenated hemoglobin concentrations were also observed in dorsolateral prefrontal cortex. The current fNIRS results corroborate previous fMRI findings that have demonstrated the involvement of dorsolateral and ventrolateral prefrontal cortex in associative recognition. Therefore, the present study validates versatile use of fNIRS with a rapid-presentation event-related design in the investigation of neural mechanisms of associative memory. The findings of this study provide evidence that fNIRS can be a viable research method for investigating complex cognitive processes commonly of interest in cognitive neuroscience. Taken together, these results demonstrate that fNIRS can be a cost-effective and accessible experimental tool for cognitive neuroscience. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Volumetric analysis of chronic maxillary atelectasis.

    Science.gov (United States)

    Lin, Giant C; Sedaghat, Ahmad R; Bleier, Benjamin S; Holbrook, Eric H; Busaba, Nicolas Y; Yoon, Michael K; Gray, Stacey T

    2015-01-01

    The relationship between orbit and maxillary sinus volumes in patients with chronic maxillary atelectasis (CMA), commonly known as silent sinus syndrome if enophthalmos is present, is poorly understood. A retrospective review of 22 patients who underwent endoscopic sinus surgery (ESS) for CMA from 2005 to 2013 was performed. Computed tomography (CT) images were analyzed using OsiriX 5.8.2 software for volumetric analysis of the orbit and maxillary sinus at presentation and after surgical treatment with ESS. Pretreatment mean orbit volumes on the diseased side (DS) and the contralateral side (CS) were 29.22 and 26.50 mL, respectively (p Volumetric analysis is a powerful and novel method for objectively demonstrating the degree of orbit expansion and maxillary sinus contraction seen with CMA. Spontaneous maxillary sinus expansion and a decrease in orbit volume can occur after ESS, but post-ESS volumes do not return to the normal volume of the CS.

  19. Plant fibre composites - porosity and volumetric interaction

    DEFF Research Database (Denmark)

    Madsen, Bo; Thygesen, Anders; Lilholt, Hans

    2007-01-01

    the combination of a high fibre volume fraction, a low porosity and a high composite density is optimal. Experimental data from the literature on volumetric composition and density of four types of plant fibre composites are used to validate the model. It is demonstrated that the model provides a concept......Plant fibre composites contain typically a relative large amount of porosity, which considerably influences properties and performance of the composites. The large porosity must be integrated in the conversion of weight fractions into volume fractions of the fibre and matrix parts. A model...... is presented to predict the porosity as a function of the fibre weight fractions, and to calculate the related fibre and matrix volume fractions, as well as the density of the composite. The model predicts two cases of composite volumetric interaction separated by a transition fibre weight fraction, at which...

  20. Volumetric polymerization shrinkage of contemporary composite resins

    OpenAIRE

    Nagem Filho, Halim; Nagem, Haline Drumond; Francisconi, Paulo Afonso Silveira; Franco, Eduardo Batista; Mondelli, Rafael Francisco Lia; Coutinho, Kennedy Queiroz

    2007-01-01

    The polymerization shrinkage of composite resins may affect negatively the clinical outcome of the restoration. Extensive research has been carried out to develop new formulations of composite resins in order to provide good handling characteristics and some dimensional stability during polymerization. The purpose of this study was to analyze, in vitro, the magnitude of the volumetric polymerization shrinkage of 7 contemporary composite resins (Definite, Suprafill, SureFil, Filtek Z250, Fill ...

  1. Combined surface and volumetric occlusion shading

    KAUST Repository

    Schott, Matthias O.

    2012-02-01

    In this paper, a method for interactive direct volume rendering is proposed that computes ambient occlusion effects for visualizations that combine both volumetric and geometric primitives, specifically tube shaped geometric objects representing streamlines, magnetic field lines or DTI fiber tracts. The proposed algorithm extends the recently proposed Directional Occlusion Shading model to allow the rendering of those geometric shapes in combination with a context providing 3D volume, considering mutual occlusion between structures represented by a volume or geometry. © 2012 IEEE.

  2. Volumetric and superficial characterization of carbon activated

    International Nuclear Information System (INIS)

    Carrera G, L.M.; Garcia S, I.; Jimenez B, J.; Solache R, M.; Lopez M, B.; Bulbulian G, S.; Olguin G, M.T.

    2000-01-01

    The activated carbon is the resultant material of the calcination process of natural carbonated materials as coconut shells or olive little bones. It is an excellent adsorbent of diluted substances, so much in colloidal form, as in particles form. Those substances are attracted and retained by the carbon surface. In this work is make the volumetric and superficial characterization of activated carbon treated thermically (300 Centigrade) in function of the grain size average. (Author)

  3. Effect of confounding variables on hemodynamic response function estimation using averaging and deconvolution analysis: An event-related NIRS study.

    Science.gov (United States)

    Aarabi, Ardalan; Osharina, Victoria; Wallois, Fabrice

    2017-07-15

    Slow and rapid event-related designs are used in fMRI and functional near-infrared spectroscopy (fNIRS) experiments to temporally characterize the brain hemodynamic response to discrete events. Conventional averaging (CA) and the deconvolution method (DM) are the two techniques commonly used to estimate the Hemodynamic Response Function (HRF) profile in event-related designs. In this study, we conducted a series of simulations using synthetic and real NIRS data to examine the effect of the main confounding factors, including event sequence timing parameters, different types of noise, signal-to-noise ratio (SNR), temporal autocorrelation and temporal filtering on the performance of these techniques in slow and rapid event-related designs. We also compared systematic errors in the estimates of the fitted HRF amplitude, latency and duration for both techniques. We further compared the performance of deconvolution methods based on Finite Impulse Response (FIR) basis functions and gamma basis sets. Our results demonstrate that DM was much less sensitive to confounding factors than CA. Event timing was the main parameter largely affecting the accuracy of CA. In slow event-related designs, deconvolution methods provided similar results to those obtained by CA. In rapid event-related designs, our results showed that DM outperformed CA for all SNR, especially above -5 dB regardless of the event sequence timing and the dynamics of background NIRS activity. Our results also show that periodic low-frequency systemic hemodynamic fluctuations as well as phase-locked noise can markedly obscure hemodynamic evoked responses. Temporal autocorrelation also affected the performance of both techniques by inducing distortions in the time profile of the estimated hemodynamic response with inflated t-statistics, especially at low SNRs. We also found that high-pass temporal filtering could substantially affect the performance of both techniques by removing the low-frequency components of

  4. MR volumetric assessment of endolymphatic hydrops

    International Nuclear Information System (INIS)

    Guerkov, R.; Berman, A.; Jerin, C.; Krause, E.; Dietrich, O.; Flatz, W.; Ertl-Wagner, B.; Keeser, D.

    2015-01-01

    We aimed to volumetrically quantify endolymph and perilymph spaces of the inner ear in order to establish a methodological basis for further investigations into the pathophysiology and therapeutic monitoring of Meniere's disease. Sixteen patients (eight females, aged 38-71 years) with definite unilateral Meniere's disease were included in this study. Magnetic resonance (MR) cisternography with a T2-SPACE sequence was combined with a Real reconstruction inversion recovery (Real-IR) sequence for delineation of inner ear fluid spaces. Machine learning and automated local thresholding segmentation algorithms were applied for three-dimensional (3D) reconstruction and volumetric quantification of endolymphatic hydrops. Test-retest reliability was assessed by the intra-class coefficient; correlation of cochlear endolymph volume ratio with hearing function was assessed by the Pearson correlation coefficient. Endolymph volume ratios could be reliably measured in all patients, with a mean (range) value of 15 % (2-25) for the cochlea and 28 % (12-40) for the vestibulum. Test-retest reliability was excellent, with an intra-class coefficient of 0.99. Cochlear endolymphatic hydrops was significantly correlated with hearing loss (r = 0.747, p = 0.001). MR imaging after local contrast application and image processing, including machine learning and automated local thresholding, enable the volumetric quantification of endolymphatic hydrops. This allows for a quantitative assessment of the effect of therapeutic interventions on endolymphatic hydrops. (orig.)

  5. A volumetric data system for environmental robotics

    International Nuclear Information System (INIS)

    Tourtellott, J.

    1994-01-01

    A three-dimensional, spatially organized or volumetric data system provides an effective means for integrating and presenting environmental sensor data to robotic systems and operators. Because of the unstructed nature of environmental restoration applications, new robotic control strategies are being developed that include environmental sensors and interactive data interpretation. The volumetric data system provides key features to facilitate these new control strategies including: integrated representation of surface, subsurface and above-surface data; differentiation of mapped and unmapped regions in space; sculpting of regions in space to best exploit data from line-of-sight sensors; integration of diverse sensor data (for example, dimensional, physical/geophysical, chemical, and radiological); incorporation of data provided at different spatial resolutions; efficient access for high-speed visualization and analysis; and geometric modeling tools to update a open-quotes world modelclose quotes of an environment. The applicability to underground storage tank remediation and buried waste site remediation are demonstrated in several examples. By integrating environmental sensor data into robotic control, the volumetric data system will lead to safer, faster, and more cost-effective environmental cleanup

  6. MR volumetric assessment of endolymphatic hydrops

    Energy Technology Data Exchange (ETDEWEB)

    Guerkov, R.; Berman, A.; Jerin, C.; Krause, E. [University of Munich, Department of Otorhinolaryngology Head and Neck Surgery, Grosshadern Medical Centre, Munich (Germany); University of Munich, German Centre for Vertigo and Balance Disorders, Grosshadern Medical Centre, Marchioninistr. 15, 81377, Munich (Germany); Dietrich, O.; Flatz, W.; Ertl-Wagner, B. [University of Munich, Institute of Clinical Radiology, Grosshadern Medical Centre, Munich (Germany); Keeser, D. [University of Munich, Institute of Clinical Radiology, Grosshadern Medical Centre, Munich (Germany); University of Munich, German Centre for Vertigo and Balance Disorders, Grosshadern Medical Centre, Marchioninistr. 15, 81377, Munich (Germany); University of Munich, Department of Psychiatry and Psychotherapy, Innenstadtkliniken Medical Centre, Munich (Germany)

    2014-10-16

    We aimed to volumetrically quantify endolymph and perilymph spaces of the inner ear in order to establish a methodological basis for further investigations into the pathophysiology and therapeutic monitoring of Meniere's disease. Sixteen patients (eight females, aged 38-71 years) with definite unilateral Meniere's disease were included in this study. Magnetic resonance (MR) cisternography with a T2-SPACE sequence was combined with a Real reconstruction inversion recovery (Real-IR) sequence for delineation of inner ear fluid spaces. Machine learning and automated local thresholding segmentation algorithms were applied for three-dimensional (3D) reconstruction and volumetric quantification of endolymphatic hydrops. Test-retest reliability was assessed by the intra-class coefficient; correlation of cochlear endolymph volume ratio with hearing function was assessed by the Pearson correlation coefficient. Endolymph volume ratios could be reliably measured in all patients, with a mean (range) value of 15 % (2-25) for the cochlea and 28 % (12-40) for the vestibulum. Test-retest reliability was excellent, with an intra-class coefficient of 0.99. Cochlear endolymphatic hydrops was significantly correlated with hearing loss (r = 0.747, p = 0.001). MR imaging after local contrast application and image processing, including machine learning and automated local thresholding, enable the volumetric quantification of endolymphatic hydrops. This allows for a quantitative assessment of the effect of therapeutic interventions on endolymphatic hydrops. (orig.)

  7. Validation of the Emotiv EPOC EEG system for research quality auditory event-related potentials in children

    OpenAIRE

    Badcock, Nicholas A.; Preece, Kathryn A.; de Wit, Bianca; Glenn, Katharine; Fieder, Nora; Thie, Johnson; McArthur, Genevieve

    2015-01-01

    Background. Previous work has demonstrated that a commercial gaming electroencephalography (EEG) system, Emotiv EPOC, can be adjusted to provide valid auditory event-related potentials (ERPs) in adults that are comparable to ERPs recorded by a research-grade EEG system, Neuroscan. The aim of the current study was to determine if the same was true for children. Method. An adapted Emotiv EPOC system and Neuroscan system were used to make simultaneous EEG recordings in nineteen 6- to 12-year-old...

  8. Neural correlates of conceptual object priming in young and older adults: An event-related fMRI study

    OpenAIRE

    Ballesteros, Soledad; Bischof, Gérard N.; Goh, Joshua O.; Park, Denise C.

    2012-01-01

    In this event-related fMRI study, we investigated age-related differences in brain activity associated with conceptual repetition priming in young and older adults. Participants performed a speeded “living/non-living” classification task with three repetitions of familiar objects. Both young and older adults showed a similar magnitude of behavioral priming to repeated objects and evidencing repetition-related activation reductions in fusiform gyrus, superior occipital, middle and inferior tem...

  9. Self-esteem modulates automatic attentional responses to self-relevant stimuli: evidence from event-related brain potentials

    OpenAIRE

    Chen, Jie; Shui, Qing; Zhong, Yiping

    2015-01-01

    Previous studies have widely shown that self-esteem modulates the attention bias towards social rejection or emotion-related information. However, little is known about the influences of self-esteem on attention bias towards self-relevant stimuli. We aimed to investigate neural correlates that underlie the modulation effect of self-esteem on self-relevant processing. Event-related potentials (ERP) were recorded for subjects’ own names and close others’ names (the names of their friends) while...

  10. A Mixed L2 Norm Regularized HRF Estimation Method for Rapid Event-Related fMRI Experiments

    Directory of Open Access Journals (Sweden)

    Yu Lei

    2013-01-01

    Full Text Available Brain state decoding or “mind reading” via multivoxel pattern analysis (MVPA has become a popular focus of functional magnetic resonance imaging (fMRI studies. In brain decoding, stimulus presentation rate is increased as fast as possible to collect many training samples and obtain an effective and reliable classifier or computational model. However, for extremely rapid event-related experiments, the blood-oxygen-level-dependent (BOLD signals evoked by adjacent trials are heavily overlapped in the time domain. Thus, identifying trial-specific BOLD responses is difficult. In addition, voxel-specific hemodynamic response function (HRF, which is useful in MVPA, should be used in estimation to decrease the loss of weak information across voxels and obtain fine-grained spatial information. Regularization methods have been widely used to increase the efficiency of HRF estimates. In this study, we propose a regularization framework called mixed L2 norm regularization. This framework involves Tikhonov regularization and an additional L2 norm regularization term to calculate reliable HRF estimates. This technique improves the accuracy of HRF estimates and significantly increases the classification accuracy of the brain decoding task when applied to a rapid event-related four-category object classification experiment. At last, some essential issues such as the impact of low-frequency fluctuation (LFF and the influence of smoothing are discussed for rapid event-related experiments.

  11. Volumetric PIV and 2D OH PLIF imaging in the far-field of a low Reynolds number nonpremixed jet flame

    International Nuclear Information System (INIS)

    Gamba, M; Clemens, N T; Ezekoye, O A

    2013-01-01

    Cinematographic stereoscopic PIV with temporal and spatial resolution ranging from 2.6 to 5.5 Kolmogorov scales, which is sufficient to accurately represent most of the dissipation structures, is used in conjunction with Taylor’s frozen flow hypothesis to generate quasi-instantaneous pseudo-volumes of the three-component velocity field in the far-field of a nonpremixed jet flame at the jet exit Reynolds number (Re d ) of 8000. The 3D data enable the computation of the nine components of the velocity gradient tensor and other important kinematic quantities. The volumetric PIV is combined with single-shot simultaneous OH PLIF imaging to mark the instantaneous reaction zone at one plane in the reconstructed volume. The combined datasets enable the investigation of the relationship between the reaction zone and the fully-3D representations of strain, vorticity, kinetic energy dissipation and dilatation, and of the impact of heat release on the structure of turbulence. In this Re d = 8000 flame, it is observed that sheet-like layers of vorticity and dissipation tend to coincide and are aligned with the OH layers, an effect that is believed to be due to the stabilizing effect of heat release on this relatively low Reynolds number jet flame. Furthermore, the spatial organization of the strain field is predominantly driven by the presence of the flame rather than turbulence. Finally, intense dissipation is mostly due to the laminar shear caused by the presence of the flame rather than to the strain generated by vortical structures as typically observed in nonreacting jets. (paper)

  12. Volumetric polymerization shrinkage of contemporary composite resins

    Directory of Open Access Journals (Sweden)

    Halim Nagem Filho

    2007-10-01

    Full Text Available The polymerization shrinkage of composite resins may affect negatively the clinical outcome of the restoration. Extensive research has been carried out to develop new formulations of composite resins in order to provide good handling characteristics and some dimensional stability during polymerization. The purpose of this study was to analyze, in vitro, the magnitude of the volumetric polymerization shrinkage of 7 contemporary composite resins (Definite, Suprafill, SureFil, Filtek Z250, Fill Magic, Alert, and Solitaire to determine whether there are differences among these materials. The tests were conducted with precision of 0.1 mg. The volumetric shrinkage was measured by hydrostatic weighing before and after polymerization and calculated by known mathematical equations. One-way ANOVA (a or = 0.05 was used to determine statistically significant differences in volumetric shrinkage among the tested composite resins. Suprafill (1.87±0.01 and Definite (1.89±0.01 shrank significantly less than the other composite resins. SureFil (2.01±0.06, Filtek Z250 (1.99±0.03, and Fill Magic (2.02±0.02 presented intermediate levels of polymerization shrinkage. Alert and Solitaire presented the highest degree of polymerization shrinkage. Knowing the polymerization shrinkage rates of the commercially available composite resins, the dentist would be able to choose between using composite resins with lower polymerization shrinkage rates or adopting technical or operational procedures to minimize the adverse effects deriving from resin contraction during light-activation.

  13. Volumetrically controlled ultrafiltration. Current experiences and future prospects.

    Science.gov (United States)

    Roy, T; Ahrenholz, P; Falkenhagen, D; Klinkmann, H

    1982-05-01

    Exact control of ultrafiltration (UF) is a prerequisite for high flux dialysis and hemodiafiltration. Volumetric dialysate balancing is the best current method for the use of dialyzers with high water permeabilities. The precision of UF control by volumetric dialysate balancing is in agreement with all medical requirements. A positive influence of volumetric UF control on patients undergoing chronic hemodialysis can be shown by the frequencies of dialysis side effects. Volumetric UF control is only a first step towards an intelligent UF module to correlate water removal, solute removal and sodium balance.

  14. Multivariate Bayesian decoding of single-trial event-related fMRI responses for memory retrieval of voluntary actions.

    Directory of Open Access Journals (Sweden)

    Dongha Lee

    Full Text Available This study proposes a method for classifying event-related fMRI responses in a specialized setting of many known but few unknown stimuli presented in a rapid event-related design. Compared to block design fMRI signals, classification of the response to a single or a few stimulus trial(s is not a trivial problem due to contamination by preceding events as well as the low signal-to-noise ratio. To overcome such problems, we proposed a single trial-based classification method of rapid event-related fMRI signals utilizing sparse multivariate Bayesian decoding of spatio-temporal fMRI responses. We applied the proposed method to classification of memory retrieval processes for two different classes of episodic memories: a voluntarily conducted experience and a passive experience induced by watching a video of others' actions. A cross-validation showed higher classification performance of the proposed method compared to that of a support vector machine or of a classifier based on the general linear model. Evaluation of classification performances for one, two, and three stimuli from the same class and a correlation analysis between classification accuracy and target stimulus positions among trials suggest that presenting two target stimuli at longer inter-stimulus intervals is optimal in the design of classification experiments to identify the target stimuli. The proposed method for decoding subject-specific memory retrieval of voluntary behavior using fMRI would be useful in forensic applications in a natural environment, where many known trials can be extracted from a simulation of everyday tasks and few target stimuli from a crime scene.

  15. Changes in fMRI magnitude data and phase data observed in block-design and event-related tasks.

    Science.gov (United States)

    Arja, Sunil Kumar; Feng, Zhaomei; Chen, Zikuan; Caprihan, Arvind; Kiehl, Kent A; Adali, Tülay; Calhoun, Vince D

    2010-02-15

    Functional magnetic resonance imaging (fMRI) data are acquired as a complex image pair including magnitude and phase information. The vast majority of fMRI experiments do not attempt to take advantage of the time varying phase information. The phase of the MRI signal is related to the local magnetic field changes, suggesting it may contain useful information about the source of hemodynamic activity. Analysis of phase data acquired from different fMRI experiments has shown the presence of activity in response to various stimuli. However, there have been no studies that have examined phase data in a larger group of subjects for multiple types of fMRI tasks nor have studies examined phase changes due to event-related stimuli. In this paper, we evaluate the correspondence between the magnitude and phase changes at a group level in a block-design motor tapping task and in an event-related auditory oddball task. The results for both block-design and event-related tasks indicate the presence of task-related information in the phase data with phase-only and magnitude-only approaches showing signal changes in the expected brain regions. Although there is more overall activity detected with magnitude data, the phase-only analysis also reveals activity in regions expected to be involved in the task, some of which were not significantly activated in the magnitude-only analysis, suggesting that the phase might provide some unique information. In addition, the phase can potentially increase sensitivity within regions also showing magnitude changes. Future work should focus on additional methods for combining the magnitude and phase data. Copyright 2009 Elsevier Inc. All rights reserved.

  16. Perceiving temporal regularity in music: the role of auditory event-related potentials (ERPs) in probing beat perception.

    Science.gov (United States)

    Honing, Henkjan; Bouwer, Fleur L; Háden, Gábor P

    2014-01-01

    The aim of this chapter is to give an overview of how the perception of a regular beat in music can be studied in humans adults, human newborns, and nonhuman primates using event-related brain potentials (ERPs). Next to a review of the recent literature on the perception of temporal regularity in music, we will discuss in how far ERPs, and especially the component called mismatch negativity (MMN), can be instrumental in probing beat perception. We conclude with a discussion on the pitfalls and prospects of using ERPs to probe the perception of a regular beat, in which we present possible constraints on stimulus design and discuss future perspectives.

  17. A step into the anarchist’s mind: examining political attitudes and ideology through event-related brain potentials

    Science.gov (United States)

    Van Hiel, Alain; Pattyn, Sven; Onraet, Emma; Severens, Els

    2012-01-01

    The present study investigates patterns of event-related brain potentials following the presentation of attitudinal stimuli among political moderates (N = 12) and anarchists (N = 11). We used a modified oddball paradigm to investigate the evaluative inconsistency effect elicited by stimuli embedded in a sequence of contextual stimuli with an opposite valence. Increased late positive potentials (LPPs) of extreme political attitudes were observed. Moreover, this LPP enhancement was larger among anarchists than among moderates, indicating that an extreme political attitude of a moderate differs from an extreme political attitude of an anarchist. The discussion elaborates on the meaning of attitude extremity for moderates and extremists. PMID:21421734

  18. Do event-related potentials to infrequent decrements in duration of auditory stimuli demonstrate a memory trace in man?

    Science.gov (United States)

    Näätänen, R; Paavilainen, P; Reinikainen, K

    1989-12-15

    Sequences of identical acoustic stimuli were presented to normal subjects reading a book while event-related brain potentials (ERP) elicited by these stimuli were recorded. Occasional irrelevant decreases and increases in stimulus duration elicited an ERP component called the mismatch negativity (MMN). This component was larger over the right hemisphere irrespective of the ear stimulated. These data implicate memory representations which develop automatically and represent the physical features of the repetitive stimulus accurately. Further, when an input does not match with such a trace the MMN is generated. The memory traces involved appear to be those of the acoustic sensory memory, the 'echoic' memory.

  19. Do event-related potentials reveal the mechanism of the auditory sensory memory in the human brain?

    Science.gov (United States)

    Näätänen, R; Paavilainen, P; Alho, K; Reinikainen, K; Sams, M

    1989-03-27

    Event-related brain potentials (ERP) to task-irrelevant tone pips presented at short intervals were recorded from the scalp of normal human subjects. Infrequent decrements in stimulus intensity elicited the mismatch negativity (MMN) which was larger in amplitude and shorter in latency the softer the deviant stimulus was. The results obtained imply memory representations which develop automatically and accurately represent the physical features of the repetitive stimulus. These memory traces appear to be those of the acoustic sensory memory, the 'echoic' memory. When an input does not match with such a trace the MMN is generated.

  20. An Auditory Go/No-Go Study of Event-Related Potentials in Children with Fetal Alcohol Spectrum Disorders

    DEFF Research Database (Denmark)

    Steinmann, Tobias P.; Andrew, Colin M.; Thomsen, Carsten E.

    2011-01-01

    Abstract—In this study event-related potentials (ERPs) were used to investigate the effects of prenatal alcohol exposure on response inhibition identified during task performance. ERPs were recorded during a auditory Go/No Go task in two groups of children with mean age of 12:8years (11years to 14......:7years): one diagnosed with fetal alcohol syndrome (FAS) or partial FAS (FAS/PFAS; n = 12) and a control group of children of same age whose mothers abstained from alcohol or drank minimally during pregnancy (n = 11). The children were instructed to push a button in response to the Go stimulus...