  1. Miniature mass analyzer

    CERN Document Server

    Cuna, C; Lupsa, N; Cuna, S; Tuzson, B

    2003-01-01

    The paper presents the concept of different mass analyzers that were specifically designed as small dimension instruments able to detect with great sensitivity and accuracy the main environmental pollutants. The mass spectrometers are very suited instrument for chemical and isotopic analysis, needed in environmental surveillance. Usually, this is done by sampling the soil, air or water followed by laboratory analysis. To avoid drawbacks caused by sample alteration during the sampling process and transport, the 'in situ' analysis is preferred. Theoretically, any type of mass analyzer can be miniaturized, but some are more appropriate than others. Quadrupole mass filter and trap, magnetic sector, time-of-flight and ion cyclotron mass analyzers can be successfully shrunk, for each of them some performances being sacrificed but we must know which parameters are necessary to be kept unchanged. To satisfy the miniaturization criteria of the analyzer, it is necessary to use asymmetrical geometries, with ion beam obl...

  2. Data acquisition and analysis system for the ion microprobe mass analyzer

    International Nuclear Information System (INIS)

    Darby, D.M.; Cristy, S.S.

    1979-02-01

    A computer was interfaced to an ion microprobe mass analyzer for more rapid data acquisition and analysis. The interface is designed to allow data acquisition, independent of the computer. A large data analysis package was developed and implemented. Performance of the computerized system was evaluated and compared to manual operation

  3. Set-up with electrostatic analyzer for mass spectrometers

    International Nuclear Information System (INIS)

    Ivanov, V.P.; Sysoev, A.A.; Samsonov, G.A.

    1977-01-01

    An attachment with an electrostatic analyzer that enables to implement a double focusing of ion beams when used in conjunction with a magnetic analyzer, is suggested. Used as the electrostatic analyzer is a cylindrical capacitor placed in a vacuum chamber. Apart from this, the attachment includes a vacuum pump, a nitrogen trap, a battery supply unit, one-beam ion receivers and a bellows inlet for capacitor adjustment. All assemblies and parts of the attachment are made of stainless steel. The test of a combined operation of the mass-spactrometer and the attachment indicate that the use of the attachment enables the utilization of sources which form ion beams with an energy dispersion of up to 1.5%, the mass-spectrometer resolving power being unchanged

  4. Time-of-flight SIMS/MSRI reflectron mass analyzer and method

    Science.gov (United States)

    Smentkowski, Vincent S.; Gruen, Dieter M.; Krauss, Alan R.; Schultz, J. Albert; Holecek, John C.

    1999-12-28

    A method and apparatus for analyzing the surface characteristics of a sample by Secondary Ion Mass Spectroscopy (SIMS) and Mass Spectroscopy of Recoiled Ions (MSRI) is provided. The method includes detecting back scattered primary ions, low energy ejected species, and high energy ejected species by ion beam surface analysis techniques comprising positioning a ToF SIMS/MSRI mass analyzer at a predetermined angle .theta., where .theta. is the angle between the horizontal axis of the mass analyzer and the undeflected primary ion beam line, and applying a specific voltage to the back ring of the analyzer. Preferably, .theta. is less than or equal to about 120.degree. and, more preferably, equal to 74.degree.. For positive ion analysis, the extractor, lens, and front ring of the reflectron are set at negative high voltages (-HV). The back ring of the reflectron is set at greater than about +700V for MSRI measurements and between the range of about +15 V and about +50V for SIMS measurements. The method further comprises inverting the polarity of the potentials applied to the extractor, lens, front ring, and back ring to obtain negative ion SIMS and/or MSRI data.

  5. Mass spectrometer calibration of Cosmic Dust Analyzer

    Science.gov (United States)

    Ahrens, Thomas J.; Gupta, Satish C.; Jyoti, G.; Beauchamp, J. L.

    2003-02-01

    The time-of-flight (TOF) mass spectrometer (MS) of the Cosmic Dust Analyzer (CDA) instrument aboard the Cassini spacecraft is expected to be placed in orbit about Saturn to sample submicrometer-diameter ring particles and impact ejecta from Saturn's satellites. The CDA measures a mass spectrum of each particle that impacts the chemical analyzer sector of the instrument. Particles impact a Rh target plate at velocities of 1-100 km/s and produce some 10-8 to 10-5 times the particle mass of positive valence, single-charged ions. These are analyzed via a TOF MS. Initial tests employed a pulsed N2 laser acting on samples of kamacite, pyrrhotite, serpentine, olivine, and Murchison meteorite induced bursts of ions which were detected with a microchannel plate and a charge sensitive amplifier (CSA). Pulses from the N2 laser (1011 W/cm2) are assumed to simulate particle impact. Using aluminum alloy as a test sample, each pulse produces a charge of ~4.6 pC (mostly Al+1), whereas irradiation of a stainless steel target produces a ~2.8 pC (Fe+1) charge. Thus the present system yields ~10-5% of the laser energy in resulting ions. A CSA signal indicates that at the position of the microchannel plate, the ion detector geometry is such that some 5% of the laser-induced ions are collected in the CDA geometry. Employing a multichannel plate detector in this MS yields for Al-Mg-Cu alloy and kamacite targets well-defined peaks at 24 (Mg+1), 27(Al+1), and 64 (Cu+1) and 56 (Fe+1), 58 (Ni+1), and 60 (Ni+1) dalton, respectively.

  6. Evaluation of Rheological Properties of Apple Mass Based Desserts

    OpenAIRE

    Sigita Boca; Ruta Galoburda; Inta Krasnova; Dalija Seglina; Aivars Aboltins; Imants Skrupskis

    2013-01-01

    The aim of the study was to evaluate the effect of texturizers on the rheological properties of the apple mass and desserts made from various raw materials. The apple varieties - ‘Antonovka’, ‘Baltais Dzidrais’, and ‘Zarja Alatau’ harvested in Latvia, were used for the experiment. The apples were processed in a blender unpeeled for obtaining a homogenous mass. The apple mass was analyzed fresh and after storage at –18ºC. Both fresh and thawed apple mass samples with added...

  7. The expanding universe of mass analyzer configurations for biological analysis.

    Science.gov (United States)

    Calvete, Juan J

    2014-01-01

    Mass spectrometry (MS) is an analytical technique that measures the mass-to-charge ratio of electrically charged gas-phase particles. All mass spectrometers combine ion formation, mass analysis, and ion detection. Although mass analyzers can be regarded as sophisticated devices that manipulate ions in space and time, the rich diversity of possible ways to combine ion separation, focusing, and detection in dynamic mass spectrometers accounts for the large number of instrument designs. A historical perspective of the progress in mass spectrometry that since 1965 until today have contributed to position this technique as an indispensable tool for biological research has been recently addressed by a privileged witness of this golden age of MS (Gelpí J. Mass Spectrom 43:419-435, 2008; Gelpí J. Mass Spectrom 44:1137-1161, 2008). The aim of this chapter is to highlight the view that the operational principles of mass spectrometry can be understood by a simple mathematical language, and that an understanding of the basic concepts of mass spectrometry is necessary to take the most out of this versatile technique.

  8. Ion optics of a time-of-flight mass spectrometer with electrostatic sector analyzers

    International Nuclear Information System (INIS)

    Sakurai, T.; Ito, H.; Matsuo, T.

    1995-01-01

    The ion optics for a high resolution time-of-flight mass spectrometer with electrostatic sector analyzers have been investigated. The multiple focusing (triple isochronous focusing and triple spacial focusing) conditions can be achieved by using a symmetrical arrangement of the sectors in a mass spectrometer. Both high mass resolution and high ion transmission can be accomplished simultaneously. The principles of MS/MS and MS/MS/MS analyses using a TOF mass spectrometer with electrostatic sector analyzers have been proposed. Product ion spectra can be obtained by measuring the total flight times and the kinetic energy of the products without any additional separation processes, any coincidence techniques or any special timing circuits. In an experiment, MS/MS and MS/MS/MS mass spectra have been obtained. The first generation product ions have been produced by a metastable decay, and the second generation products have been produced by a sequential decay. (orig.)

  9. Mass analyzer ``MASHA'' high temperature target and plasma ion source

    Science.gov (United States)

    Semchenkov, A. G.; Rassadov, D. N.; Bekhterev, V. V.; Bystrov, V. A.; Chizov, A. Yu.; Dmitriev, S. N.; Efremov, A. A.; Guljaev, A. V.; Kozulin, E. M.; Oganessian, Yu. Ts.; Starodub, G. Ya.; Voskresensky, V. M.; Bogomolov, S. L.; Paschenko, S. V.; Zelenak, A.; Tikhonov, V. I.

    2004-05-01

    A new separator and mass analyzer of super heavy atoms (MASHA) has been created at the FLNR JINR Dubna to separate and measure masses of nuclei and molecules with precision better than 10-3. First experiments with the FEBIAD plasma ion source have been done and give an efficiency of ionization of up to 20% for Kr with a low flow test leak (6 particle μA). We suppose a magnetic field optimization, using the additional electrode (einzel lens type) in the extracting system, and an improving of the vacuum conditions in order to increase the ion source efficiency.

  10. Mass analyzer 'MASHA' high temperature target and plasma ion source

    International Nuclear Information System (INIS)

    Semchenkov, A.G.; Rassadov, D.N.; Bekhterev, V.V.; Bystrov, V.A.; Chizov, A.Yu.; Dmitriev, S.N.; Efremov, A.A.; Guljaev, A.V.; Kozulin, E.M.; Oganessian, Yu.Ts.; Starodub, G.Ya.; Voskresensky, V.M.; Bogomolov, S.L.; Paschenko, S.V.; Zelenak, A.; Tikhonov, V.I.

    2004-01-01

    A new separator and mass analyzer of super heavy atoms (MASHA) has been created at the FLNR JINR Dubna to separate and measure masses of nuclei and molecules with precision better than 10 -3 . First experiments with the FEBIAD plasma ion source have been done and give an efficiency of ionization of up to 20% for Kr with a low flow test leak (6 particle μA). We suppose a magnetic field optimization, using the additional electrode (einzel lens type) in the extracting system, and an improving of the vacuum conditions in order to increase the ion source efficiency

  11. Turning an energy analyzer into a mass spectrometer and a charge sorter

    International Nuclear Information System (INIS)

    Lee, K.

    2004-01-01

    Full text:When a swarm of ions are accelerated by a pulsed electric field for a common duration before entering an electrostatically dispersive energy analyzer, they will be sorted according to their charge-to-mass ratio q/m. In other words, the apparent kinetic energy upon which an ion will be registered in an apparent 'energy' spectrum thus obtained is proportional to its q/m ratio. For ions of a fixed mass m, the apparent energy spectrum becomes a charge state distribution spectrum. For ions of a fixed charge q, the apparent energy spectrum becomes a mass spectrum. In essence, an energy analyzer becomes both a charge sorter and a mass spectrometer when operated in this mode. When this technique is brought to bear on the detection of photofragment ions, a distinct advantage emerges. Kinetic energy release distribution (KERD) of fragment ions conventionally is extracted from fitting of the ion time-of-flight profile to ion trajectory simulation results, as such a fair amount of uncertainty exists in the KERD thus obtained. With the current novel approach to mass spectrometry, the KERDs of photofragment ions can be obtained directly, and as a result, with a greater accuracy. This should advance the study of fragmentation dynamics considerably

  12. The calculus and the design of a miniature quadrupole mass filter: a selected solution from different types of mass analyzers

    International Nuclear Information System (INIS)

    Cuna, C.; Ioanoviciu, D.; Lupsa, N.; Chis, A.

    2002-01-01

    The mass spectrometers are very precise tools used in chemical and isotopic analysis for environmental surveillance. Traditionally environmental analysis is done by sampling the soil, air or water and taking the sample back to the laboratory for analysis. To avoid the difficulties related with the sample alteration during the sampling process and the transport the analysis 'in situ' is to be preferred. This type of analysis combines the sampling and analysis and produces an analytical result almost instantly. Fast-response detection methods are highly desirable in cases where relatively short-lived species are to be examined. Theoretically, any type of mass analyzers can be miniaturized, but some are better suited for miniaturization than others. We studied comparatively different types of mass analyzers that can be miniaturized, especially quadrupole, magnetic sector and time of flight types, in view to select from all these, the best solution for our purpose, the application to the 'in situ' environmental monitoring and inspection, analytical process control. We investigated and calculated the properties of some geometrical arrangements that we reported, one of these being a double focusing mass analyzer with electric deflector and magnetic deflector combined in a reversed geometry. From the different calculated versions we selected the following one, with the characteristic parameters: n = 62, f = 2 MHz, L = 0.07 m, r 0 = 2.616 x 10 -3 m, E z = 5 V, R housing = 3.5 r 0 , V m = 1000 V, R max = 200, M max = 200 u. Starting from these mechanical and electrical parameters we calculated and designed a miniature quadrupole mass spectrometer. A theoretical study of the ion trajectories in the quadrupole analyzer by matrix formalism as well as by using Mathieu functions was made. Using the program SIMION 6, the trajectories inside the quadrupole filter were also simulated. The calculus of the ion trajectories starts by numerically solving of the Mathieu type equation

  13. Innovative application of the moisture analyzer for determination of dry mass content of processed cheese

    Science.gov (United States)

    Kowalska, Małgorzata; Janas, Sławomir; Woźniak, Magdalena

    2018-04-01

    The aim of this work was the presentation of an alternative method of determination of the total dry mass content in processed cheese. The authors claim that the presented method can be used in industry's quality control laboratories for routine testing and for quick in-process control. For the test purposes both reference method of determination of dry mass in processed cheese and moisture analyzer method were used. The tests were carried out for three different kinds of processed cheese. In accordance with the reference method, the sample was placed on a layer of silica sand and dried at the temperature of 102 °C for about 4 h. The moisture analyzer test required method validation, with regard to drying temperature range and mass of the analyzed sample. Optimum drying temperature of 110 °C was determined experimentally. For Hochland cream processed cheese sample, the total dry mass content, obtained using the reference method, was 38.92%, whereas using the moisture analyzer method, it was 38.74%. An average analysis time in case of the moisture analyzer method was 9 min. For the sample of processed cheese with tomatoes, the reference method result was 40.37%, and the alternative method result was 40.67%. For the sample of cream processed cheese with garlic the reference method gave value of 36.88%, and the alternative method, of 37.02%. An average time of those determinations was 16 min. Obtained results confirmed that use of moisture analyzer is effective. Compliant values of dry mass content were obtained for both of the used methods. According to the authors, the fact that the measurement took incomparably less time for moisture analyzer method, is a key criterion of in-process control and final quality control method selection.

  14. OpenMSI Arrayed Analysis Toolkit: Analyzing Spatially Defined Samples Using Mass Spectrometry Imaging

    Energy Technology Data Exchange (ETDEWEB)

    de Raad, Markus [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); de Rond, Tristan [Univ. of California, Berkeley, CA (United States); Rübel, Oliver [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Keasling, Jay D. [Univ. of California, Berkeley, CA (United States); Joint BioEnergy Inst. (JBEI), Emeryville, CA (United States); Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Technical Univ. of Denmark, Lyngby (Denmark); Northen, Trent R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); USDOE Joint Genome Institute (JGI), Walnut Creek, CA (United States); Bowen, Benjamin P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); USDOE Joint Genome Institute (JGI), Walnut Creek, CA (United States)

    2017-05-03

    Mass spectrometry imaging (MSI) has primarily been applied in localizing biomolecules within biological matrices. Although well-suited, the application of MSI for comparing thousands of spatially defined spotted samples has been limited. One reason for this is a lack of suitable and accessible data processing tools for the analysis of large arrayed MSI sample sets. In this paper, the OpenMSI Arrayed Analysis Toolkit (OMAAT) is a software package that addresses the challenges of analyzing spatially defined samples in MSI data sets. OMAAT is written in Python and is integrated with OpenMSI (http://openmsi.nersc.gov), a platform for storing, sharing, and analyzing MSI data. By using a web-based python notebook (Jupyter), OMAAT is accessible to anyone without programming experience yet allows experienced users to leverage all features. OMAAT was evaluated by analyzing an MSI data set of a high-throughput glycoside hydrolase activity screen comprising 384 samples arrayed onto a NIMS surface at a 450 μm spacing, decreasing analysis time >100-fold while maintaining robust spot-finding. The utility of OMAAT was demonstrated for screening metabolic activities of different sized soil particles, including hydrolysis of sugars, revealing a pattern of size dependent activities. Finally, these results introduce OMAAT as an effective toolkit for analyzing spatially defined samples in MSI. OMAAT runs on all major operating systems, and the source code can be obtained from the following GitHub repository: https://github.com/biorack/omaat.

  15. Evaluation of errors for mass-spectrometric analysis with surface-ionization type mass-spectrometer (statistical evaluation of mass-discrimination effect)

    International Nuclear Information System (INIS)

    Wada, Y.

    1981-01-01

    The surface-ionization type mass-spectrometer is widely used as an apparatus for quality assurance, accountability and safeguarding of nuclear materials, and for this analysis it has become an important factor to statistically evaluate an analytical error which consists of a random error and a systematic error. The major factor of this systematic error was the mass-discrimination effect. In this paper, various assays for evaluating the factor of variation on the mass-discrimination effect were studied and the data obtained were statistically evaluated. As a result of these analyses, it was proved that the factor of variation on the mass-discrimination effect was not attributed to the acid concentration of sample, sample size on the filament and supplied voltage for a multiplier, but mainly to the filament temperature during the mass-spectrometric analysis. The mass-discrimination effect values β which were usually calculated from the measured data of uranium, plutonium or boron isotopic standard sample were not so significant dependently of the difference of U-235, Pu-239 or B-10 isotopic abundance. Furthermore, in the case of U and Pu, measurement conditions and the mass range of these isotopes were almost similar, and these values β were not statistically significant between U and Pu. On the other hand, the value β for boron was about a third of the value β for U or Pu, but compared with the coefficient of the correction on the mass-discrimination effect for the difference of mass-number, ΔM, these coefficient values were almost the same among U, Pu, and B.As for the isotopic analysis error of U, Pu, Nd and B, it was proved that the isotopic abundance of these elements and the isotopic analysis error were in a relationship of quadratic curves on a logarithmic-logarithmic scale

  16. Optimizing recoil-isomer tagging with the Argonne fragment mass analyzer

    International Nuclear Information System (INIS)

    Garnsworthy, A.B.; Lister, C.J.; Regan, P.H.; Blank, B.B.; Cullen, I.J.; Gros, S.; Henderson, D.J.; Jones, G.A.; Liu, Z.; Seweryniak, D.; Shumard, B.R.; Thompson, N.J.; Williams, S.J.; Zhu, S.

    2008-01-01

    A new focal plane detector arrangement for the Fragment Mass Analyzer (FMA) has been built and tested at Argonne National Laboratory. This set-up is particularly sensitive for performing Recoil-Isomer Tagging on nuclei with isomeric states with lifetimes in the microsecond range. Recoiling nuclei from fusion-evaporation reactions at the target position are dispersed by their ratio of mass to charge (A/q) by the FMA and stopped in low pressure gas (air) at the focal plane. Subsequent gamma decays from isomeric states in the reaction products are observed using Ge detectors. A constant gas flow through the focal plane chamber efficiently removes longer-lived beta-decaying species from sight of the detectors. This set-up has been commissioned successfully with the microsecond isomer in 80 Rb, populated via the 52 Cr( 32 S, 3pn) reaction at 135 MeV

  17. Atomic masses 1995. The 1995 atomic mass evaluation

    International Nuclear Information System (INIS)

    Audi, G.; Wapstra, A.H.

    1995-01-01

    The 1995 atomic mass evaluation by G. Audi and A.H. Wapstra is documented. The resulting data files containing recommended values of atomic masses, obtained by experiment or systematics, and related data such as reaction and separation energies are described. The data files can be obtained through online services from several nuclear data centers or on magnetic tape, free of charge. (author)

  18. Atomic masses 1993. The 1993 atomic mass evaluation

    International Nuclear Information System (INIS)

    Audi, G.; Wapstra, A.H.

    1993-01-01

    The 1993 atomic mass evaluation by G. Audi and A.H. Wapstra is documented. The resulting data files containing recommended values of atomic masses, obtained by experiment of systematics, and related data such as reaction and separation energies are described. The data files can be obtained through online services from several nuclear data centers or on magnetic tape, free of charge. (author)

  19. A Dual Source Ion Trap Mass Spectrometer for the Mars Organic Molecule Analyzer of ExoMars 2018

    Science.gov (United States)

    Brickerhoff, William B.; vanAmerom, F. H. W.; Danell, R. M.; Arevalo, R.; Atanassova, M.; Hovmand, L.; Mahaffy, P. R.; Cotter, R. J.

    2011-01-01

    We present details on the objectives, requirements, design and operational approach of the core mass spectrometer of the Mars Organic Molecule Analyzer (MOMA) investigation on the 2018 ExoMars mission. The MOMA mass spectrometer enables the investigation to fulfill its objective of analyzing the chemical composition of organic compounds in solid samples obtained from the near surface of Mars. Two methods of ionization are realized, associated with different modes of MOMA operation, in a single compact ion trap mass spectrometer. The stringent mass and power constraints of the mission have led to features such as low voltage and low frequency RF operation [1] and pulse counting detection.

  20. MS2Analyzer: A Software for Small Molecule Substructure Annotations from Accurate Tandem Mass Spectra

    Science.gov (United States)

    2015-01-01

    Systematic analysis and interpretation of the large number of tandem mass spectra (MS/MS) obtained in metabolomics experiments is a bottleneck in discovery-driven research. MS/MS mass spectral libraries are small compared to all known small molecule structures and are often not freely available. MS2Analyzer was therefore developed to enable user-defined searches of thousands of spectra for mass spectral features such as neutral losses, m/z differences, and product and precursor ions from MS/MS spectra in MSP/MGF files. The software is freely available at http://fiehnlab.ucdavis.edu/projects/MS2Analyzer/. As the reference query set, 147 literature-reported neutral losses and their corresponding substructures were collected. This set was tested for accuracy of linking neutral loss analysis to substructure annotations using 19 329 accurate mass tandem mass spectra of structurally known compounds from the NIST11 MS/MS library. Validation studies showed that 92.1 ± 6.4% of 13 typical neutral losses such as acetylations, cysteine conjugates, or glycosylations are correct annotating the associated substructures, while the absence of mass spectra features does not necessarily imply the absence of such substructures. Use of this tool has been successfully demonstrated for complex lipids in microalgae. PMID:25263576

  1. Aluminum surface modification by a non-mass-analyzed nitrogen ion beam

    Science.gov (United States)

    Ohira, Shigeo; Iwaki, Masaya

    Non-mass-analyzed nitrogen ion implantation into polycrystal and single crystal aluminum sheets has been carried out at an accelerating voltage of 90 kV and a dose of 1 × 10 18 N ions/cm 2 using a Zymet implanter model Z-100. The pressure during implantation rose to 10 -3 Pa due to the influence of N gas feeding into the ion source. The characteristics of the surface layers were investigated by means of Auger electron spectroscopy (AES), X-ray diffraction (XRD), transmission electron diffraction (TED), and microscopy (TEM). The AES depth profiling shows a rectangular-like distribution of N atoms and little migration of O atoms near the surface. The high dose N-implantation forms c-axis oriented aluminum nitride (AIN) crystallines, and especially irradiation of Al single crystals with N ions leads to the formation of a hcp AlN single crystal. It is concluded that the high dose N-implantation in Al can result in the formation of AlN at room temperature without any thermal annealing. Furthermore, non-mass-analyzed N-implantation at a pressure of 10 -3 Pa of the nitrogen atmosphere causes the formation of pure AlN single crystals in the Al surface layer and consequently it can be practically used for AlN production.

  2. Following the Ions through a Mass Spectrometer with Atmospheric Pressure Interface: Simulation of Complete Ion Trajectories from Ion Source to Mass Analyzer.

    Science.gov (United States)

    Zhou, Xiaoyu; Ouyang, Zheng

    2016-07-19

    Ion trajectory simulation is an important and useful tool in instrumentation development for mass spectrometry. Accurate simulation of the ion motion through the mass spectrometer with atmospheric pressure ionization source has been extremely challenging, due to the complexity in gas hydrodynamic flow field across a wide pressure range as well as the computational burden. In this study, we developed a method of generating the gas flow field for an entire mass spectrometer with an atmospheric pressure interface. In combination with the electric force, for the first time simulation of ion trajectories from an atmospheric pressure ion source to a mass analyzer in vacuum has been enabled. A stage-by-stage ion repopulation method has also been implemented for the simulation, which helped to avoid an intolerable computational burden for simulations at high pressure regions while it allowed statistically meaningful results obtained for the mass analyzer. It has been demonstrated to be suitable to identify a joint point for combining the high and low pressure fields solved individually. Experimental characterization has also been done to validate the new method for simulation. Good agreement was obtained between simulated and experimental results for ion transfer though an atmospheric pressure interface with a curtain gas.

  3. Performance evaluation of enzyme immunoassay for voriconazole therapeutic drug monitoring with automated clinical chemistry analyzers.

    Science.gov (United States)

    Jeon, Yongbum; Han, Minje; Han, Eun Young; Lee, Kyunghoon; Song, Junghan; Song, Sang Hoon

    2017-08-01

    Voriconazole is a triazole antifungal developed for the treatment of fungal infectious disease, and the clinical utility of its therapeutic drug monitoring has been evaluated. Recently, a new assay for analyzing the serum voriconazole concentration with an automated clinical chemistry analyzer was developed. We evaluated the performance of the new assay based on standardized protocols. The analytical performance of the assay was evaluated according to its precision, trueness by recovery, limit of quantitation, linearity, and correlation with results from liquid chromatography-tandem mass spectrometry (LC-MS/MS). The evaluation was performed with the same protocol on two different routine chemistry analyzers. All evaluations were performed according to CLSI Guidelines EP15, EP17, EP6, and EP9 [1-4]. Coefficients of variation for within-run and between-day imprecision were 3.2-5.1% and 1.5-3.0%, respectively, on the two different analyzers for pooled serum samples. The recovery rates were in the range of 95.4-102.2%. The limit of blank was 0.0049 μg/mL, and the limit of detection of the samples was 0.0266-0.0376 μg/mL. The percent recovery at three LoQ levels were 67.9-74.6% for 0.50 μg/mL, 75.5-80.2% for 0.60 μg/mL, and 89.9-96.6% for 0.70 μg/mL. A linear relationship was demonstrated between 0.5 μg/mL and 16.0 μg/mL ( R 2 =0.9995-0.9998). The assay correlated well with LC-MS/MS results ( R 2 =0.9739-0.9828). The assay showed acceptable precision, trueness, linearity, and limit of quantification, and correlated well with LC-MS/MS. Therefore, its analytical performance is satisfactory for monitoring the drug concentration of voriconazole.

  4. Evaluation of performance of veterinary in-clinic hematology analyzers.

    Science.gov (United States)

    Rishniw, Mark; Pion, Paul D

    2016-12-01

    A previous study provided information regarding the quality of in-clinic veterinary biochemistry testing. However, no similar studies for in-clinic veterinary hematology testing have been conducted. The objective of this study was to assess the quality of hematology testing in veterinary in-clinic laboratories using results obtained from testing 3 levels of canine EDTA blood samples. Clinicians prepared blood samples to achieve measurand concentrations within, below, and above their RIs and evaluated the samples in triplicate using their in-clinic analyzers. Quality was assessed by comparison of calculated total error with quality requirements, determination of sigma metrics, use of a quality goal index, and agreement between in-clinic and reference laboratory instruments. Suitability for statistical quality control was determined using adaptations from the computerized program, EZRules3. Evaluation of 10 veterinary in-clinic hematology analyzers showed that these instruments often fail to meet quality requirements. At least 60% of analyzers reasonably determined RBC, WBC, HCT, and HGB, when assessed by most quality goal criteria; platelets were less reliably measured, with 80% deemed suitable for low platelet counts, but only 30% for high platelet counts, and automated differential leukocyte counts were generally considered unsuitable for clinical use with fewer than 40% of analyzers meeting the least stringent quality goal requirements. Fewer than 50% of analyzers were able to meet requirements for statistical quality control for any measurand. These findings reflect the current status of in-clinic hematology analyzer performance and provide a basis for future evaluations of the quality of veterinary laboratory testing. © 2016 American Society for Veterinary Clinical Pathology.

  5. History and status of atomic mass measurement and evaluation

    International Nuclear Information System (INIS)

    Huang Wenxue; Zhu Zhichao; Wang Meng; Wang Yue; Tian Yulin; Xu Hushan; Xiao Guoqing

    2010-01-01

    Mass is one of the most fundamental properties that can be obtained about an atomic nucleus. High-accuracy mass values for atoms let us study the atomic and nuclear binding energies that represent the sum of all the atomic and nucleonic interactions. Looking on the history of nuclear masses, it can be found that it is almost as old as that of nuclear physics itself. The experimental methods for masses and the relevant outcomes are so rich that the evaluation is needed to check the consistency among the various results and obtain more reliable data. The atomic mass evaluation is a considerate and complicated process. This paper introduces briefly the history and status of atomic mass measurement and evaluation. (authors)

  6. Congenital cystic masses of the face and neck: CT evaluation

    International Nuclear Information System (INIS)

    Chung, Hae Gyeong; Kim, Hyung Jin; Kim, Jae Hyoung; Hwang, Eui Gee; Jeon, Sea Young; Kim, Sun Young; Chung, Sung Hoon

    1991-01-01

    Recognition of the congenital cystic masses of the face and neck is important because they are usually benign, and can be completely cured by surgical excision. We retrospective analyzed CT scan of 18 surgically proven congenital cystic masses of the face and neck. The cases included 5 thyroglossal duct cysts, 4 cystic hygromas, 5 dermoid cysts, 1 branchial cleft cyst, and 3 fissural cysts of the face. Of five cases of thyroglossal duct cysts, CT showed either a well-marginated, rim enhancing unilocular cystic mass (n=3), or a diffuse but heterogeneous highly enhancing soft tissue mass (n=2). The latter two cases were confirmed later as infected thyroglossal duct cysts. Four cases of cystic hygromas were seen as either an irregularly-marginated (n=3) or a well-marginated (n=1) rim enhancing multiseptated cystic mass with a fluid-fluid level. Five cases of dermoid cysts appeared as well-marginated rim enhancing unilocular ovoid masses. The content of each mass was predominantly fluid in four cases, of which additional solid components were found in two, and interspersed fat globules in one. One case was composed of a homogeneous fatty density. One case of branchial cleft cyst was in the anterior triangle near the left mandibular angle, and appeared as a well-marginated enhancing cystic mass with a thick rim. In this case displacement of the adjacent structures was noted also. All three cases of fissural cysts of the face were seen as a well-marginated, rim enhancing cystic mass, causing a smooth pressure erosion of the adjacent bones. We conclude that CT is useful for the evaluation of the congenital cystic masses of the face and neck, because it can differentiate various forms of the congenital lesions and is able to clearly reveal the relation of the mass to the adjacent structures

  7. Congenital cystic masses of the face and neck: CT evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hae Gyeong; Kim, Hyung Jin; Kim, Jae Hyoung; Hwang, Eui Gee; Jeon, Sea Young; Kim, Sun Young; Chung, Sung Hoon [Gyeongsang National University, Jinju (Korea, Republic of)

    1991-09-15

    Recognition of the congenital cystic masses of the face and neck is important because they are usually benign, and can be completely cured by surgical excision. We retrospective analyzed CT scan of 18 surgically proven congenital cystic masses of the face and neck. The cases included 5 thyroglossal duct cysts, 4 cystic hygromas, 5 dermoid cysts, 1 branchial cleft cyst, and 3 fissural cysts of the face. Of five cases of thyroglossal duct cysts, CT showed either a well-marginated, rim enhancing unilocular cystic mass (n=3), or a diffuse but heterogeneous highly enhancing soft tissue mass (n=2). The latter two cases were confirmed later as infected thyroglossal duct cysts. Four cases of cystic hygromas were seen as either an irregularly-marginated (n=3) or a well-marginated (n=1) rim enhancing multiseptated cystic mass with a fluid-fluid level. Five cases of dermoid cysts appeared as well-marginated rim enhancing unilocular ovoid masses. The content of each mass was predominantly fluid in four cases, of which additional solid components were found in two, and interspersed fat globules in one. One case was composed of a homogeneous fatty density. One case of branchial cleft cyst was in the anterior triangle near the left mandibular angle, and appeared as a well-marginated enhancing cystic mass with a thick rim. In this case displacement of the adjacent structures was noted also. All three cases of fissural cysts of the face were seen as a well-marginated, rim enhancing cystic mass, causing a smooth pressure erosion of the adjacent bones. We conclude that CT is useful for the evaluation of the congenital cystic masses of the face and neck, because it can differentiate various forms of the congenital lesions and is able to clearly reveal the relation of the mass to the adjacent structures.

  8. Evaluation of Virtual Refrigerant Mass Flow Sensors

    OpenAIRE

    Kim, Woohyun; Braun, James E.

    2012-01-01

    Refrigerant mass flow rate is an important measurement for monitoring equipment performance and enabling fault detection and diagnostics. However, a traditional mass flow meter is expensive to purchase and install. A virtual refrigerant mass flow sensor (VRMF) uses a mathematical model to estimate flow rate using low-cost measurements and can potentially be implemented at low cost. This study evaluates three VRMFs for estimating refrigerant mass flow rate. The first model uses a compressor ma...

  9. Plain Language Summary: Evaluation of the Neck Mass in Adults.

    Science.gov (United States)

    Pynnonen, Melissa A; Colandrea, Maria; Finestone, Sandra A; O'Connor, Sarah S

    2017-09-01

    This plain language summary serves as an overview in explaining the evaluation of the neck mass in adults. The summary applies to patients aged ≥18 years and is based on the 2017 "Clinical Practice Guideline: Evaluation of the Neck Mass in Adults." The evidence-based guideline includes research to support more effective evaluation and diagnosis of the neck mass in adults. The guideline was developed as a quality improvement opportunity for evaluation of the neck mass by creating clear recommendations to use in medical practice.

  10. Proof of Concept Coded Aperture Miniature Mass Spectrometer Using a Cycloidal Sector Mass Analyzer, a Carbon Nanotube (CNT) Field Emission Electron Ionization Source, and an Array Detector

    Science.gov (United States)

    Amsden, Jason J.; Herr, Philip J.; Landry, David M. W.; Kim, William; Vyas, Raul; Parker, Charles B.; Kirley, Matthew P.; Keil, Adam D.; Gilchrist, Kristin H.; Radauscher, Erich J.; Hall, Stephen D.; Carlson, James B.; Baldasaro, Nicholas; Stokes, David; Di Dona, Shane T.; Russell, Zachary E.; Grego, Sonia; Edwards, Steven J.; Sperline, Roger P.; Denton, M. Bonner; Stoner, Brian R.; Gehm, Michael E.; Glass, Jeffrey T.

    2018-02-01

    Despite many potential applications, miniature mass spectrometers have had limited adoption in the field due to the tradeoff between throughput and resolution that limits their performance relative to laboratory instruments. Recently, a solution to this tradeoff has been demonstrated by using spatially coded apertures in magnetic sector mass spectrometers, enabling throughput and signal-to-background improvements of greater than an order of magnitude with no loss of resolution. This paper describes a proof of concept demonstration of a cycloidal coded aperture miniature mass spectrometer (C-CAMMS) demonstrating use of spatially coded apertures in a cycloidal sector mass analyzer for the first time. C-CAMMS also incorporates a miniature carbon nanotube (CNT) field emission electron ionization source and a capacitive transimpedance amplifier (CTIA) ion array detector. Results confirm the cycloidal mass analyzer's compatibility with aperture coding. A >10× increase in throughput was achieved without loss of resolution compared with a single slit instrument. Several areas where additional improvement can be realized are identified.

  11. Performance evaluation of Samsung LABGEO(HC10) Hematology Analyzer.

    Science.gov (United States)

    Park, Il Joong; Ahn, Sunhyun; Kim, Young In; Kang, Seon Joo; Cho, Sung Ran

    2014-08-01

    The Samsung LABGEO(HC10) Hematology Analyzer (LABGEO(HC10)) is a recently developed automated hematology analyzer that uses impedance technologies. The analyzer provides 18 parameters including 3-part differential at a maximum rate of 80 samples per hour. To evaluate the performance of the LABGEO(HC10). We evaluated precision, linearity, carryover, and relationship for complete blood cell count parameters between the LABGEO(HC10) and the LH780 (Beckman Coulter Inc) in a university hospital in Korea according to the Clinical and Laboratory Standards Institute guidelines. Sample stability and differences due to the anticoagulant used (K₂EDTA versus K₃EDTA) were also evaluated. The LABGEO(HC10) showed linearity over a wide range and minimal carryover ( 0.92) except for mean corpuscular hemoglobin concentration. The bias estimated was acceptable for all parameters investigated except for monocyte count. Most parameters were stable until 24 hours both at room temperature and at 4°C. The difference by anticoagulant type was statistically insignificant for all parameters except for a few red cell parameters. The accurate results achievable and simplicity of operation make the unit recommendable for small to medium-sized laboratories.

  12. A Method for Analyzing the Dynamic Response of a Structural System with Variable Mass, Damping and Stiffness

    Directory of Open Access Journals (Sweden)

    Mike D.R. Zhang

    2001-01-01

    Full Text Available In this paper, a method for analyzing the dynamic response of a structural system with variable mass, damping and stiffness is first presented. The dynamic equations of the structural system with variable mass and stiffness are derived according to the whole working process of a bridge bucket unloader. At the end of the paper, an engineering numerical example is given.

  13. Development and Evaluation of a Reverse-Entry Ion Source Orbitrap Mass Spectrometer

    Science.gov (United States)

    Poltash, Michael L.; McCabe, Jacob W.; Patrick, John W.; Laganowsky, Arthur; Russell, David H.

    2018-05-01

    As a step towards development of a high-resolution ion mobility mass spectrometer using the orbitrap mass analyzer platform, we describe herein a novel reverse-entry ion source (REIS) coupled to the higher-energy C-trap dissociation (HCD) cell of an orbitrap mass spectrometer with extended mass range. Development of the REIS is a first step in the development of a drift tube ion mobility-orbitrap MS. The REIS approach retains the functionality of the commercial instrument ion source which permits the uninterrupted use of the instrument during development as well as performance comparisons between the two ion sources. Ubiquitin (8.5 kDa) and lipid binding to the ammonia transport channel (AmtB, 126 kDa) protein complex were used as model soluble and membrane proteins, respectively, to evaluate the performance of the REIS instrument. Mass resolution obtained with the REIS is comparable to that obtained using the commercial ion source. The charge state distributions for ubiquitin and AmtB obtained on the REIS are in agreement with previous studies which suggests that the REIS-orbitrap EMR retains native structure in the gas phase.

  14. Performance evaluation of enzyme immunoassay for voriconazole therapeutic drug monitoring with automated clinical chemistry analyzers

    Directory of Open Access Journals (Sweden)

    Yongbum Jeon

    2017-08-01

    Full Text Available Objective: Voriconazole is a triazole antifungal developed for the treatment of fungal infectious disease, and the clinical utility of its therapeutic drug monitoring has been evaluated. Recently, a new assay for analyzing the serum voriconazole concentration with an automated clinical chemistry analyzer was developed. We evaluated the performance of the new assay based on standardized protocols. Methods: The analytical performance of the assay was evaluated according to its precision, trueness by recovery, limit of quantitation, linearity, and correlation with results from liquid chromatography-tandem mass spectrometry (LC-MS/MS. The evaluation was performed with the same protocol on two different routine chemistry analyzers. All evaluations were performed according to CLSI Guidelines EP15, EP17, EP6, and EP9 [1–4]. Results: Coefficients of variation for within-run and between-day imprecision were 3.2–5.1% and 1.5–3.0%, respectively, on the two different analyzers for pooled serum samples. The recovery rates were in the range of 95.4–102.2%. The limit of blank was 0.0049 μg/mL, and the limit of detection of the samples was 0.0266–0.0376 μg/mL. The percent recovery at three LoQ levels were 67.9–74.6% for 0.50 μg/mL, 75.5–80.2% for 0.60 μg/mL, and 89.9–96.6% for 0.70 μg/mL. A linear relationship was demonstrated between 0.5 μg/mL and 16.0 μg/mL (R2=0.9995–0.9998. The assay correlated well with LC-MS/MS results (R2=0.9739–0.9828. Conclusions: The assay showed acceptable precision, trueness, linearity, and limit of quantification, and correlated well with LC-MS/MS. Therefore, its analytical performance is satisfactory for monitoring the drug concentration of voriconazole. Keywords: Voriconazole, Antifungal agents, Therapeutic drug monitoring

  15. An optimized two-step derivatization method for analyzing diethylene glycol ozonation products using gas chromatography and mass spectrometry.

    Science.gov (United States)

    Yu, Ran; Duan, Lei; Jiang, Jingkun; Hao, Jiming

    2017-03-01

    The ozonation of hydroxyl compounds (e.g., sugars and alcohols) gives a broad range of products such as alcohols, aldehydes, ketones, and carboxylic acids. This study developed and optimized a two-step derivatization procedure for analyzing polar products of aldehydes and carboxylic acids from the ozonation of diethylene glycol (DEG) in a non-aqueous environment using gas chromatography-mass spectrometry. Experiments based on Central Composite Design with response surface methodology were carried out to evaluate the effects of derivatization variables and their interactions on the analysis. The most desirable derivatization conditions were reported, i.e., oximation was performed at room temperature overnight with the o-(2,3,4,5,6-pentafluorobenzyl) hydroxyl amine to analyte molar ratio of 6, silylation reaction temperature of 70°C, reaction duration of 70min, and N,O-bis(trimethylsilyl)-trifluoroacetamide volume of 12.5μL. The applicability of this optimized procedure was verified by analyzing DEG ozonation products in an ultrafine condensation particle counter simulation system. Copyright © 2016. Published by Elsevier B.V.

  16. Evaluation of the mass measles vaccination campaign in Guangdong Province, China.

    Science.gov (United States)

    Peng, Zhi Qiang; Chen, Wei Shi; He, Qun; Peng, Guo Wen; Wu, Cheng Gang; Xu, Ning; Zhao, Zhan Jie; Shu, Jun; Tan, Qiu; Zheng, Hui Zhen; Lin, Li Feng; Deng, Hui Hong; Lin, Jin Yan; Zhang, Yong Hui

    2012-02-01

    To evaluate the mass measles vaccination campaign of 2009 in Guangdong Province, China. Data on the campaign implementation, measles surveillance, and serological surveillance were reviewed and analyzed by statistical methods. Rapid coverage surveys showed that 98.09% of children were vaccinated during the campaign. The coverage of migrant children increased significantly from 67.10% to 97.32% (pvaccinated during the campaign. Flyers, notices of information from doctors, and television programs were the best methods to inform parents of the campaign. Awareness of the campaign by residents increased significantly from 91.86% to 97.10% (pvaccination campaign approach for controlling measles in a developing region like Guangdong Province with a vast migrant population has proved effective. Comprehensive mobilization, communication with the mass media, and support from government departments were critical to the success of the campaign. Copyright © 2011 International Society for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  17. The AME2003 atomic mass evaluation (I). Evaluation of input data, adjustment procedures

    International Nuclear Information System (INIS)

    Wapstra, A.H.; Audi, G.; Thibault, C.

    2003-01-01

    This paper is the first of two parts presenting the result of a new evaluation of atomic masses (AME2003). In this first part we give full information on the used and rejected input data and on the procedures used in deriving the tables in the second part. We first describe the philosophy and procedures used in selecting nuclear-reaction, decay, and mass spectrometric results as input values in a least-squares evaluation of best values for atomic masses. The calculation procedures and particularities of the AME are then described. All accepted data, and rejected ones with a reported precision still of interest, are presented in a table and compared there with the adjusted values. The differences with the earlier evaluation are briefly discussed and information is given of interest for the users of this AME. The second paper for the AME2003, last in this issue, gives a table of atomic masses, tables and graphs of derived quantities, and the list of references used in both this evaluation and the NUBASE2003 table (first paper in this issue). AMDC: http://csnwww.in2p3.fr/AMDC/

  18. Isotope ratio analysis by a combination of element analyzer and mass spectrometer

    International Nuclear Information System (INIS)

    Pichlmayer, F.

    1987-06-01

    The use of stable isotope ratios of carbon, nitrogen and sulfur as analytical tool in many fields of research is of growing interest. A method has therefore been developed, consisting in essential of coupling an Elemental Analyzer with an Isotope Mass Spectrometer, which enables the gas preparation of carbon dioxide, nitrogen and sulfur dioxide from any solid or liquid sample in a fast and easy way. Results of carbon isotope measurements in food analysis are presented, whereat it is possible to check origin and treatment of sugar, oils, fats, mineral waters, spirituous liquors etc. and to detect adulterations as well. Also applications in the field of environmental research are given. (Author)

  19. OpenMSI Arrayed Analysis Toolkit: Analyzing Spatially Defined Samples Using Mass Spectrometry Imaging

    DEFF Research Database (Denmark)

    de Raad, Markus; de Rond, Tristan; Rübel, Oliver

    2017-01-01

    ://openmsinersc.gov), a platform for storing, sharing, and analyzing MSI data. By using a web-based python notebook (Jupyter), OMAAT is accessible to anyone without programming experience yet allows experienced users to leverage all features. OMAAT was :evaluated by analyzing an MSI data set of a high-throughput glycoside...... processing tools for the analysis of large arrayed MSI sample sets. The OpenMSI Arrayed Analysis Toolkit (OMAAT) is a software package that addresses the challenges of analyzing spatially defined samples in MSI data sets. OMAAT is written in Python and is integrated with OpenMSI (http...

  20. Evaluation of incompressible hydrodynamic mass methods in reactor applications

    International Nuclear Information System (INIS)

    Takeuchi, K.

    1981-01-01

    The hydrodynamic (or virtual) mass approach is evaluated by comparison of structural responses computed by the hydrodynamic mass method with those computed by MULTIFLEX code for a fluid/structure interaction problem with fluid compression effects taken into account. A sample problem used in that evaluation is a simplified 1-D PWR model which is first subjected to a LOCA type transient. The time history of structural displacement computed with the hydrodynamic mass approach is compared with MULTIFLEX results. The frequencies of structural oscillation of these two computations agree. The amplitudes disagree by more than 50%, which is attributed to the effect of fluid compressibility. For the seismic study, sinusoidal forces are applied to the floor at the vessel support. The system responses are expressed by the response functions or the maximum values of the barrel/vessel relative displacements as the applied frequency is varied. The response functions are computed by the hydrodynamic mass method and by MULTIFLEX for evaluation of the virtual mass method. For the pump pulsation study, sinusoidal pressure oscillations are applied at the pump outlet and the response functions are computed as above. 12 refs

  1. Non-contact micro mass evaluation method using an X-ray microscope

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jiseok; Sun, Gwang Min; Baek, Ha Ni; Hoang, Sy Minh Tuan; Park, Sun Ae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2017-07-15

    For the mass inspection of attached foils such as printed electrodes, mass should be measured by a non-contact method with the capacity to measure a small mass of micrograms. In this study, the masses of 1 mg to 10 mg electrodes were evaluated using an X-ray microscope. The results were compared with the masses determined by using a digital scale with a 0.005 mg error. The average of the relative error between the mass measurements using the X-ray microscope and those using the digital scale was less than 2.51%. The results show that X-ray mass evaluation method can be used for mass measurement of micro objects by replacing a digital scale.

  2. Quality evaluation of tandem mass spectral libraries.

    Science.gov (United States)

    Oberacher, Herbert; Weinmann, Wolfgang; Dresen, Sebastian

    2011-06-01

    Tandem mass spectral libraries are gaining more and more importance for the identification of unknowns in different fields of research, including metabolomics, forensics, toxicology, and environmental analysis. Particularly, the recent invention of reliable, robust, and transferable libraries has increased the general acceptance of these tools. Herein, we report on results obtained from thorough evaluation of the match reliabilities of two tandem mass spectral libraries: the MSforID library established by the Oberacher group in Innsbruck and the Weinmann library established by the Weinmann group in Freiburg. Three different experiments were performed: (1) Spectra of the libraries were searched against their corresponding library after excluding either this single compound-specific spectrum or all compound-specific spectra prior to searching; (2) the libraries were searched against each other using either library as reference set or sample set; (3) spectra acquired on different mass spectrometric instruments were matched to both libraries. Almost 13,000 tandem mass spectra were included in this study. The MSforID search algorithm was used for spectral matching. Statistical evaluation of the library search results revealed that principally both libraries enable the sensitive and specific identification of compounds. Due to higher mass accuracy of the QqTOF compared with the QTrap instrument, matches to the MSforID library were more reliable when comparing spectra with both libraries. Furthermore, only the MSforID library was shown to be efficiently transferable to different kinds of tandem mass spectrometers, including "tandem-in-time" instruments; this is due to the coverage of a large range of different collision energy settings-including the very low range-which is an outstanding characteristics of the MSforID library.

  3. The Ame2012 atomic mass evaluation. Pt. 1. Evaluation of input data, adjustment procedures

    International Nuclear Information System (INIS)

    Audi, G; Wang, M.; Wapstra, A.H.; Kondev, F.G.; MacCormick, M.; Xu, X.; Pfeiffer, B.

    2012-01-01

    This paper is the first of two articles (Part I and Part II) that presents the results of the new atomic mass evaluation, Ame2012. It includes complete information on the experimental input data (including not used and rejected ones), as well as details on the evaluation procedures used to derive the tables with recommended values given in the second part. This article describes the evaluation philosophy and procedures that were implemented in the selection of specific nuclear reaction, decay and mass-spectrometer results. These input values were entered in the least-squares adjustment procedure for determining the best values for the atomic masses and their uncertainties. Calculation procedures and particularities of the AME are then described. All accepted and rejected data, including outweighed ones, are presented in a tabular format and compared with the adjusted values (obtained using the adjustment procedure). Differences with the previous Ame2003 evaluation are also discussed and specific information is presented for several cases that may be of interest to various AME users. The second Ame2012 article, the last one in this issue, gives a table with recommended values of atomic masses, as well as tables and graphs of derived quantities, along with the list of references used in both this Ame2012 evaluation and the Nubase2012 one (the first paper in this issue). (authors)

  4. Evaluation of haematology analyzer CELL-DYN 3700 SL

    Directory of Open Access Journals (Sweden)

    Enver Suljević

    2003-05-01

    Full Text Available Research on the parameters of full blood count and differential white blood count is included in the program of all medical laboratories of primary, secondary and tertiary health care levels. Today, all haematological tests are exclusively performed on the haematology analyzers. Automation of haematology laboratories is a result of the huge requires for haematological test performing, timely issuing of the haematological findings, and possibility of the usage of modern techniques.This work is an evaluation of laser haematology analyzer Cell-Dyn 3700 SL. It investigates the reliability of test results throughout the following parameters: precision, accuracy, sensitivity and specificity of determination methods. It also explores the influence of sample transferring and correlation with haematology analyzer MAXM Retti. Haematology parameters that have been investigated are: white blood cell (WBC, neutrophils (NEU, lymphocytes (LXM, monocytes (MONO, eosinophils (EOS, basophils (BASO, red blood cells (RBC, haemoglobin (HGB, haematocrit (HCT, mean corpuscular volume (MCV, mean corpuscular haemoglobin (MCHC red cell distribution width (RDW, platelet (PLT, mean platelet volume (MPV, plateletocrit (PCT, and platelet distribution width (PDW.The results confirms that precision of analyzer fulfils the reproducibility of testing parameters: WBC, RBC, HGB, MCV, MCH, MCHC, and PLT. Correlation coefficient values (r gained throughout the statistical analysis, that is linear regression results obtained throughout the comparison of two analyzers are adequate except for MCHC (r = 0.64, what is in accordance with literature data.Accuracy is tested by haematology analyzer method and microscopic differentiating method. Correlation coefficient results for granulocytes, lymphocytes and monocytes point the accuracy of methods. Sensitivity and specificity parameters fulfil the analytical criteria.It is confirmed that haematology analyzer Cell-Dyn 3700 SL is reliable for

  5. Study of impurities in Aditya Tokamak during different conditions using quadrupole mass analyzer

    International Nuclear Information System (INIS)

    Bhatt, S.B.; Jadeja, K.A.; Patel, K.M.; Patel, N.D.; Raval, M.K.; Ghosh, J.

    2015-01-01

    In fusion devices, e.g., Tokamak, the presence of the impurities, i.e. gas species other than the fuel gas, deteriorates plasma and makes confinement difficult. The gas molecules tend to get adsorbed on the surfaces of the solid state materials of the vessel wall during discharges. A Residual Gas Analyzer (RGA) is the most commonly useful instrument to measure the presence and quantity of the various gases in a vacuum system. Quadrupole Mass Analyzer (QMA) is installed on Aditya Tokamak to measure the concentrations of various gas species present in Aditya vacuum system. It is also used to monitor impurities generated during various phases of discharges in Aditya Tokamak. The impurities are reduced by various types of discharge cleaning and in-situ coatings. Presence of residual gas concentration in vacuum system creates limitation for achievement of ultrahigh vacuum and also affects plasma performance. The presence of residual gases is due to different reasons like atmospheric concentration, contamination of the wall materials, outgassing from the exposed materials, permeation, real and virtual leaks

  6. Evaluation of Portable Multi-Gas Analyzers for use by Safety Personnel

    Science.gov (United States)

    Lueck, D. E.; Meneghelli, B. J.; Bardel, D. N.

    1998-01-01

    During confined space entry operations as well as Shuttle-safing operations, United Space Alliance (USA)/National Aeronautics and Space Administration (NASA) safety personnel use a variety of portable instrumentation to monitor for hazardous levels of compounds such as nitrogen dioxide (N%), monomethylhydrazine (NMM), FREON 21, ammonia (NH3), oxygen (O2), and combustibles (as hydrogen (H2)). Except for O2 and H2, each compound is monitored using a single analyzer. In many cases these analyzers are 5 to 10 years old and require frequent maintenance. In addition, they are cumbersome to carry and tend to make the job of personnel monitoring physically taxing. As part of an effort to upgrade the sensor technology background information was requested from a total of 27 manufacturers of portable multi-gas instruments. A set of criteria was established to determine which vendors would be selected for laboratory evaluation. These criteria were based on requests made by USA/NASA Safety personnel in order to meet requirements within their respective areas for confined-space and Shuttle-safing operations. Each of the 27 manufacturers of multi-gas analyzers was sent a copy of the criteria and asked to fill in the appropriate information pertaining to their instrumentation. Based on the results of the sensor criteria worksheets, a total of 9 vendors out of 27 surveyed manufacturers were chosen for evaluation. Each vendor included in the final evaluation process was requested to configure each of two analyzers with NO2, NH3, O2, and combustible sensors. A set of lab tests was designed in order to determine which of the multi-gas instruments under evaluation was best suited for use in both shuttle and confined space operations. These tests included linearity/repeatability, zero/span drift response/recovery, humidity, interference, and maintenance. At the conclusion of lab testing three vendors were selected for additional field testing. Based on the results of both the lab and

  7. Comparative evaluation of Plateletworks, Multiplate analyzer and Platelet function analyzer-200 in cardiology patients.

    Science.gov (United States)

    Kim, Jeeyong; Cho, Chi Hyun; Jung, Bo Kyeung; Nam, Jeonghun; Seo, Hong Seog; Shin, Sehyun; Lim, Chae Seung

    2018-04-14

    The objective of this study was to comparatively evaluate three commercial whole-blood platelet function analyzer systems: Platelet Function Analyzer-200 (PFA; Siemens Canada, Mississauga, Ontario, Canada), Multiplate analyzer (MP; Roche Diagnostics International Ltd., Rotkreuz, Switzerland), and Plateletworks Combo-25 kit (PLW; Helena Laboratories, Beaumont, TX, USA). Venipuncture was performed on 160 patients who visited a department of cardiology. Pairwise agreement among the three platelet function assays was assessed using Cohen's kappa coefficient and percent agreement within the reference limit. Kappa values with the same agonists were poor between PFA-collagen (COL; agonist)/adenosine diphosphate (ADP) and MP-ADP (-0.147), PFA-COL/ADP and PLW-ADP (0.089), MP-ADP and PLW-ADP (0.039), PFA-COL/ADP and MP-COL (-0.039), and between PFA-COL/ADP and PLW-COL (-0.067). Nonetheless, kappa values for the same assay principle with a different agonist were slightly higher between PFA-COL/ADP and PFA-COL/EPI (0.352), MP-ADP and MP-COL (0.235), and between PLW-ADP and PLW-COL (0.247). The range of percent agreement values was 38.7% to 73.8%. Therefore, various measurements of platelet function by more than one method were needed to obtain a reliable interpretation of platelet function considering low kappa coefficient and modest percent agreement rates among 3 different platelet function tests.

  8. Intrahepatic and hilar mass-forming cholangiocarcinoma: Qualitative and quantitative evaluation with diffusion-weighted MR imaging.

    Science.gov (United States)

    Fattach, Hassan El; Dohan, Anthony; Guerrache, Youcef; Dautry, Raphael; Boudiaf, Mourad; Hoeffel, Christine; Soyer, Philippe

    2015-08-01

    To qualitatively and quantitatively analyze the presentation of intrahepatic and hilar mass-forming cholangiocarcinoma with diffusion-weighted magnetic resonance imaging (DW-MRI). Twenty-eight patients with histopathologically proven mass-forming cholangiocarcinoma (hilar, n=17; intrahepatic, n=11) underwent hepatic DW-MRI at 1.5-T using free-breathing acquisition and three b-values (0,400,800s/mm(2)). Cholangiocarcinomas were evaluated qualitatively using visual analysis of DW-MR images and quantitatively with conventional ADC and normalized ADC measurements using liver and spleen as reference organs. All cholangiocarcinomas (28/28; 100%) were visible on DW-MR images. DW-MRI yielded best conspicuity of cholangiocarcinomas than the other MRI sequences (Philar cholangiocarcinomas. The use of normalized ADC using the liver as reference organ resulted in the most restricted distribution of ADC values of cholangiocarcinomas (variation coefficient=16.6%). There is a trend towards a common appearance of intrahepatic and hilar mass-forming cholangiocarcinomas on DW-MRI but variations may be observed. Familiarity with these variations may improve the diagnosis of mass-forming cholangiocarcinoma. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  9. How accurate is ultrasound in evaluating palpable breast masses ...

    African Journals Online (AJOL)

    Methods: Eighty palpable breast masses were evaluated at ultrasound and information about the characteristic features of the masses was recorded. An impression about the diagnosis was made and results were correlated with histology findings. Results: The overall sensitivity of ultrasound in detecting breast lumps was ...

  10. Laboratory evaluation of the Coasys® Plus C coagulation analyzer

    NARCIS (Netherlands)

    de Bie, Prim; Schornagel, Willem J.; van den Dool, Erik-Jan; Bakker, Bianca; van Dam, Willem; Heckman, Marion; Ağar, Cetin; Sturk, Auguste; Stroobants, An K.

    2013-01-01

    The Coasys® Plus C (Behnk Elektronik, distributed by Roche Diagnostics) is a coagulation analyzer for small to midsize clinical chemistry laboratories. We performed a laboratory evaluation. After a familiarization period the dead volume, carry-over, capacity, within-assay reproducibility and

  11. Study of the mass and energy resolution of the E parallel B charge exchange analyzer for TFTR

    International Nuclear Information System (INIS)

    Kaita, R.; Medley, S.S.

    1979-09-01

    The charge exchange diagnostic for TFTR requires simultaneous multispecie (H + , D + , γ + ) analysis of particles in the energy range of 0.5 - 150 keV. The analyzer design chosen to provide this capability employs a wide gap semi-circular region of superimposed parallel electric and magnetic fields to accomplish mass and energy resolution, respectively. Combined with a large area, multi-anode microchannel plate detector, this arrangement will enable the energy distributions of protons, deuterions, and tritons to be measured concurrently as a function of time during each discharge. A computer simulation program for calculating ion trajectories through the analyzer was written that includes a realistic model of the magnetic and electrostatic fringe fields. This report presents the results of a study of the proposed E parallel B analyzer, and it reveals that the fringe fields are not detrimental to the performance of the analyzer

  12. Using Outcomes to Analyze Patients Rather than Patients to Analyze Outcomes: A Step toward Pragmatism in Benefit:risk Evaluation

    Science.gov (United States)

    Evans, Scott R.; Follmann, Dean

    2016-01-01

    In the future, clinical trials will have an increased emphasis on pragmatism, providing a practical description of the effects of new treatments in realistic clinical settings. Accomplishing pragmatism requires better summaries of the totality of the evidence in ways that clinical trials consumers---patients, physicians, insurers---find transparent and allow for informed benefit:risk decision-making. The current approach to the analysis of clinical trials is to analyze efficacy and safety separately and then combine these analyses into a benefit:risk assessment. Many assume that this will effectively describe the impact on patients. But this approach is suboptimal for evaluating the totality of effects on patients. We discuss methods for benefit:risk assessment that have greater pragmatism than methods that separately analyze efficacy and safety. These include the concepts of within-patient analyses and composite benefit:risk endpoints with a goal of understanding how to analyze one patient before trying to figure out how to analyze many. We discuss the desirability of outcome ranking (DOOR) and introduce the partial credit strategy using an example in a clinical trial evaluating the effects of a new antibiotic. As part of the example we introduce a strategy to engage patients as a resource to inform benefit:risk analyses consistent with the goal of measuring and weighing outcomes that are most important from the patient’s perspective. We describe a broad vision for the future of clinical trials consistent with increased pragmatism. Greater focus on using endpoints to analyze patients rather than patients to analyze endpoints particularly in late-phase/stage clinical trials is an important part of this vision. PMID:28435515

  13. Indoor fire in a nursing home : evaluation of the medical response to a mass casualty incident based on a standardized protocol

    NARCIS (Netherlands)

    Koning, S. W.; Ellerbroek, P. M.; Leenen, L. P. H.

    This retrospective study reports the outcome of a mass casualty incident (MCI) caused by a fire in a nursing home. Data from the medical charts and registration system of the Major Incident Hospital (MIH) and ambulance service were analyzed. The evaluation reports from the MIH and an independent

  14. Evaluation of dominant thyroid masses

    International Nuclear Information System (INIS)

    Thomas, C.G. Jr.; Buckwalter, J.A.; Staab, E.V.; Kerr, C.Y.

    1976-01-01

    Controversy exists concerning the management of solitary thyroid nodules because of conflicting information concerning the high clinical incidence of thyroid nodules, the varying incidence of cancer reported in those surgically excised and the infrequency of death from thyroid cancer. During the past several years, a plan for evaluating patients with dominant thyroid masses has evolved. The objective is to avoid unnecessary operations by identifying patients with a high risk of cancer. The criteria which are used are the age and sex of the patient, the duration of the mass, 125 I or /sup 99m/Tc scans, 75 Selenomethionine scans, B-mode ultrasonography and the response of the mass to suppressive therapy. This is a report of the findings in 222 patients who have been studied employing this approach. Thirty percent of the patients were operated upon. Forty percent had neoplasms (well differentiated cancer--28.8 percent, adenoma--12.1 percent), 47.0 percent--nodular goiter, 6.1 percent cysts, and 6.1 percent chronic thyroiditis. The incidence of cancer in the 222 patients was 8.6 percent and adenoma 3.6 percent. Patients at greatest risk of having cancer are those with solid nonfunctioning nodules which fail to regress with suppressive therapy. This study indicates that the approach described above is effective in selecting for surgical excision those individuals at greatest risk of having thyroid cancer

  15. Organic environments on Saturn's moon, Titan: simulating chemical reactions and analyzing products by FT-ICR and ion-trap mass spectrometry.

    Science.gov (United States)

    Somogyi, Arpad; Oh, Chu-Ha; Smith, Mark A; Lunine, Jonathan I

    2005-06-01

    Laboratory simulations have been carried out to model chemical reactions that possibly take place in the stratosphere of Saturn's moon, Titan. The aerosol products of these reactions (tholin samples) have been systematically analyzed by mass spectrometry using electrospray ionization (ESI) and laser desorption (LD). A wide variety of ions with a general formula C(x)H(y)N(z) detected by ultrahigh resolution and accurate mass measurements in a Fourier transform/ion cyclotron resonance (FT-ICR) cell reflect the complexity of these polymeric products, both in chemical compositions and isomeric distributions. As a common feature, however, tandem mass spectral (MS/MS) data and H/D exchange products in the solution phase support the presence of amino and nitrile functionalities in these (highly unsaturated) "tholin" compounds. The present work demonstrates that ESI-MS coupled with FT-ICR is a suitable and "intact" method to analyze tholin components formed under anaerobic conditions; only species with C(x)H(y)N(z) are detected for freshly prepared and harvested samples. However, when intentionally exposed to water, oxygen-containing compounds are unambiguously detected.

  16. Analysis of corrosions-products in tissue samples near surgical implants by means of LAMMA (Laser Microprobe Mass Analyzer) and ICP-MS (Inductively Coupled Plasma Mass Spectrometer)

    International Nuclear Information System (INIS)

    Schlagenhaufen, C.

    1996-08-01

    In this work corrosion products of surgical implants in tissue samples were identified. For the characterization of the corrosion products the LAMMA 500 (Laser Microprobe Mass Analyzer) was used. Additional analysis were made with the ICP-MS (Inductively Coupled Plasma Mass Spectrometer) to determine the concentration of chromium, cobalt, nickel, and molybdenum in the tissues. In the first part several synthetic chromium- and molybdenum compounds were investigated with LAMMA. With the anionic mass spectra of the chromium-compounds it is possible to the oxidation state of chromium. The mass spectra of the synthetic compounds were used to identify, the compounds in the corrosion products. In the second part thin sections prepared from the tissue samples from the surrounding of the implants were analyzed. Several embedding and cutting methods were tested. Histological staining methods and LAMMA spectra were used to characterize the deposits in the tissue. Three different deposits were found in the tissue. In all tissues metal splinters from the implant were found. In most of the tissues iron-rich deposits were found, that were identified as iron-phosphate. As definitive corrosion products of the implant mixtures of chromium(III)phosphate, calcium molybdate, calcium phosphate and chromium(III) molybdate were identified. The ICP-MS results show in comparison to normal values, very high concentrations for chromium, nickel, cobalt and molybdenum. These results support the conclusions based on LAMMA results. The results of these investigations clearly indicate, that stainless steel implants, are not corrosion-resistant in the body. Relatively high amounts of the constituents, of the implant dissolved, and are deposited as solid compounds in the tissue next to the implant. (author)

  17. Benefit-risk evaluation of mammographic mass screening

    International Nuclear Information System (INIS)

    Sato, Nobuo; Ogura, Toshihiro

    1990-01-01

    This study evaluated the benefit-risk balance of mammography in mass screening by using survival rates from 3000 breast cancer patients at the Japanese Foundation for Cancer Research Institute Hospital. Because the number of participants in mammographic mass screening was small, asymptomatic patients with pathologically proven early breast cancer were categorized as the screenee group. Symptomatic patients were categorized as the patient group. Survival rates were compared in both the screenee and the patient groups. Based on the difference in areas of survival curves between screenees and patients, the ratio of person-year gain (PYG) to person-year lost (PYL) was obtained. The ratio of PYG to PYL was multiplied by the detection rate resulting from a particular screening program to obtain the benefit/risk ratio. The detection rate of nonpalpable breast cancer was 15 times higher in the screenee group than the patient group. Breast cancer was detected in 7 (0.85%) of 824 patients in the screenee group. Even when mammographic mass screening was started at the age of 30, the benefit of mammography was far superior to the risk. The number of participants in mass screening stratified by age may be required for the conclusion of the benefit-risk balance of mammography in mass screening. (N.K.)

  18. Cs+ ion source for secondary ion mass spectrometry

    International Nuclear Information System (INIS)

    Bentz, B.L.; Weiss, H.; Liebl, H.

    1981-12-01

    Various types of cesium ionization sources currently used in secondary ion mass spectrometry are briefly reviewed, followed by a description of the design and performance of a novel, thermal surface ionization Cs + source developed in this laboratory. The source was evaluated for secondary ion mass spectrometry applications using the COALA ion microprobe mass analyzer. (orig.)

  19. Magnetic Resonance Imaging Evaluation of Cardiac Masses

    International Nuclear Information System (INIS)

    Braggion-Santos, Maria Fernanda; Koenigkam-Santos, Marcel; Teixeira, Sara Reis; Volpe, Gustavo Jardim; Trad, Henrique Simão; Schmidt, André

    2013-01-01

    Cardiac tumors are extremely rare; however, when there is clinical suspicion, proper diagnostic evaluation is necessary to plan the most appropriate treatment. In this context, cardiovascular magnetic resonance imaging (CMRI) plays an important role, allowing a comprehensive characterization of such lesions. To review cases referred to a CMRI Department for investigation of cardiac and paracardiac masses. To describe the positive case series with a brief review of the literature for each type of lesion and the role of cardiovascular magnetic resonance imaging in evaluation. Between August 2008 and December 2011, all cases referred for CMRI with suspicion of tumor involving the heart were reviewed. Cases with positive histopathological diagnosis, clinical evolution or therapeutic response compatible with the clinical suspicion and imaging findings were selected. Among the 13 cases included in our study, eight (62%) had histopathological confirmation. We describe five benign tumors (myxomas, rhabdomyoma and fibromas), five malignancies (sarcoma, lymphoma, Richter syndrome involving the heart and metastatic disease) and three non-neoplastic lesions (pericardial cyst, intracardiac thrombus and infectious vegetation). CMRI plays an important role in the evaluation of cardiac masses of non-neoplastic and neoplastic origin, contributing to a more accurate diagnosis in a noninvasive manner and assisting in treatment planning, allowing safe clinical follow-up with good reproducibility

  20. Clinical Practice Guideline: Evaluation of the Neck Mass in Adults.

    Science.gov (United States)

    Pynnonen, Melissa A; Gillespie, M Boyd; Roman, Benjamin; Rosenfeld, Richard M; Tunkel, David E; Bontempo, Laura; Brook, Itzhak; Chick, Davoren Ann; Colandrea, Maria; Finestone, Sandra A; Fowler, Jason C; Griffith, Christopher C; Henson, Zeb; Levine, Corinna; Mehta, Vikas; Salama, Andrew; Scharpf, Joseph; Shatzkes, Deborah R; Stern, Wendy B; Youngerman, Jay S; Corrigan, Maureen D

    2017-09-01

    Objective Neck masses are common in adults, but often the underlying etiology is not easily identifiable. While infections cause most of the neck masses in children, most persistent neck masses in adults are neoplasms. Malignant neoplasms far exceed any other etiology of adult neck mass. Importantly, an asymptomatic neck mass may be the initial or only clinically apparent manifestation of head and neck cancer, such as squamous cell carcinoma (HNSCC), lymphoma, thyroid, or salivary gland cancer. Evidence suggests that a neck mass in the adult patient should be considered malignant until proven otherwise. Timely diagnosis of a neck mass due to metastatic HNSCC is paramount because delayed diagnosis directly affects tumor stage and worsens prognosis. Unfortunately, despite substantial advances in testing modalities over the last few decades, diagnostic delays are common. Currently, there is only 1 evidence-based clinical practice guideline to assist clinicians in evaluating an adult with a neck mass. Additionally, much of the available information is fragmented, disorganized, or focused on specific etiologies. In addition, although there is literature related to the diagnostic accuracy of individual tests, there is little guidance about rational sequencing of tests in the course of clinical care. This guideline strives to bring a coherent, evidence-based, multidisciplinary perspective to the evaluation of the neck mass with the intention to facilitate prompt diagnosis and enhance patient outcomes. Purpose The primary purpose of this guideline is to promote the efficient, effective, and accurate diagnostic workup of neck masses to ensure that adults with potentially malignant disease receive prompt diagnosis and intervention to optimize outcomes. Specific goals include reducing delays in diagnosis of HNSCC; promoting appropriate testing, including imaging, pathologic evaluation, and empiric medical therapies; reducing inappropriate testing; and promoting appropriate

  1. Blood gas analyzer utility in evaluating oxygen kinetics of the aqueous humor

    Directory of Open Access Journals (Sweden)

    Ismail Ersan

    2015-04-01

    Full Text Available Purpose: To measure the partial pressure of oxygen (PO2 and carbon dioxide (PCO2 and the pH of aqueous humor (AH and arterial blood samples from rabbits using a blood gas analyzer. Methods: Twenty New Zealand rabbits were anesthetized intramuscularly with ketamine and xylazine and were then allowed to breathe room air. Using a gas blood analyzer, arterial blood and AH samples were analyzed for PO2, PCO2, and pH. Results: The mean arterial blood pressure was 87.14 ± 15.0 mmHg. The mean blood and AH PO2 were 95.18 ± 11.76 mmHg and 88.83 ± 9.92 mmHg, the mean blood and AH PCO2 were 25.86 ± 5.46 mmHg and 29.50 ± 5.36 mmHg, and the mean blood and AH pH were 7.38 ± 0.06 and 7.33 ± 0.09, respectively. Conclusion: Conclusions: The blood gas analyzer was easily employed to evaluate the aqueous humor in rabbits. When comparing the results of studies evaluating aqueous PO2, care should be taken to determine the methods used in these studies.

  2. Sonography and cytology in the evaluation of salivary gland masses

    International Nuclear Information System (INIS)

    Gozzi, G.; Bazzochi, M.; Vasciaveo, A.; Bassini, A.; Bellis, G.B.; Di Bonito, L.

    1991-01-01

    The contribution of the combined use of US and cytology is evaluated in the diagnosis of masses in yhe salivary glands and adjacent structures. US had 87.2% sensitivity in locating the mass; its accuracy in defining both phisical structure and benign/malignant nature of the lesion was 91% and 74% respectively. Thus US, after demonstrating a lesion, does not always allow the exact definition of its characteristic. In many of these cases, other imaging modalities do not help either. In our series of cases, cytology allowed an unquestionable diagnosis to be made in 87.2% of cases, and the combined use of US and cytology rose the figure to 97%. The only limitation is the evaluation of the deep extent of large masses: in such cases CT or, if available, MR imaging are recommended

  3. Boundaries of mass resolution in native mass spectrometry.

    Science.gov (United States)

    Lössl, Philip; Snijder, Joost; Heck, Albert J R

    2014-06-01

    Over the last two decades, native mass spectrometry (MS) has emerged as a valuable tool to study intact proteins and noncovalent protein complexes. Studied experimental systems range from small-molecule (drug)-protein interactions, to nanomachineries such as the proteasome and ribosome, to even virus assembly. In native MS, ions attain high m/z values, requiring special mass analyzers for their detection. Depending on the particular mass analyzer used, instrumental mass resolution does often decrease at higher m/z but can still be above a couple of thousand at m/z 5000. However, the mass resolving power obtained on charge states of protein complexes in this m/z region is experimentally found to remain well below the inherent instrument resolution of the mass analyzers employed. Here, we inquire into reasons for this discrepancy and ask how native MS would benefit from higher instrumental mass resolution. To answer this question, we discuss advantages and shortcomings of mass analyzers used to study intact biomolecules and biomolecular complexes in their native state, and we review which other factors determine mass resolving power in native MS analyses. Recent examples from the literature are given to illustrate the current status and limitations.

  4. Ion mobility analyzer - quadrupole mass spectrometer system design

    International Nuclear Information System (INIS)

    Cuna, C; Leuca, M; Lupsa, N; Mirel, V; Cuna, Stela; Cosma, V; Tusa, Florina; Bocos-Bintintan, V

    2009-01-01

    Because of their extremely high sensitivity for chemicals with elevated electronegativity or high proton affinity the ion mobility analysers are ideal for the ultra-trace detection of toxic or explosive chemicals, most of these situated often at concentration levels of sub-ppb (parts-per-billion). Ion mobility spectrometers (IMS) can be used to identify illicit drugs or environmental pollutants. Since resolution of an IMS is relatively low, to achieve an accurate identification of target analyte it is recommended to couple the IMS with a quadrupole mass spectrometer (QMS) or a time of flight mass spectrometer, acquiring in this way confirmatory information. This coupling is made through a specific interface. In this paper, an experimental model of such a tandem instrument, IMS-QMS is described. Accomplishment of this general purpose will be done, overcoming a series of specific issues. This implies the solving, using innovative solutions, of a series of complex issues: ensuring the stability of the ions beam generated by ion source; transfer with a good efficiency of the ionic current from IMS analyser to QMS; and realization of a special electronic circuitry which will be able to detect both positive and negative ions.

  5. Ion mobility analyzer - quadrupole mass spectrometer system design

    Energy Technology Data Exchange (ETDEWEB)

    Cuna, C; Leuca, M; Lupsa, N; Mirel, V; Cuna, Stela; Cosma, V; Tusa, Florina [National Institute for Research and Development of Isotopic and Molecular Technologies, 65-103 Donath, 400293 Cluj-Napoca (Romania); Bocos-Bintintan, V, E-mail: cornel.cuna@itim-cj.r [Babes-Bolyai University, Faculty of Environmental Sciences, 3 Fantanele, 400294 Cluj Napoca (Romania)

    2009-08-01

    Because of their extremely high sensitivity for chemicals with elevated electronegativity or high proton affinity the ion mobility analysers are ideal for the ultra-trace detection of toxic or explosive chemicals, most of these situated often at concentration levels of sub-ppb (parts-per-billion). Ion mobility spectrometers (IMS) can be used to identify illicit drugs or environmental pollutants. Since resolution of an IMS is relatively low, to achieve an accurate identification of target analyte it is recommended to couple the IMS with a quadrupole mass spectrometer (QMS) or a time of flight mass spectrometer, acquiring in this way confirmatory information. This coupling is made through a specific interface. In this paper, an experimental model of such a tandem instrument, IMS-QMS is described. Accomplishment of this general purpose will be done, overcoming a series of specific issues. This implies the solving, using innovative solutions, of a series of complex issues: ensuring the stability of the ions beam generated by ion source; transfer with a good efficiency of the ionic current from IMS analyser to QMS; and realization of a special electronic circuitry which will be able to detect both positive and negative ions.

  6. Three-dimensional power Doppler ultrasonography in evaluation of adnexal masses

    Directory of Open Access Journals (Sweden)

    Ahmed M. Abbas

    2017-12-01

    The introduction of 3DPD has opened the possibility to characterize microvasculature of the adnexal masses and objectively assess tumor vascularization. 3DPD allows also an objective measurement of vascularity of a given region of interest by estimating 3 vascular indices (vascularization index [VI], flow index [FI], and vascularization-flow index [VFI] within such region. The aim of this review article is to evaluate the role of 3DPD in the assessment of adnexal masses vascularity, its ability to discriminate benign masses from malignant ones.

  7. The role of three-dimensional imaging in evaluation of the sinonasal mass

    Energy Technology Data Exchange (ETDEWEB)

    Shim, Sue Yon; Sung, Ki Joon; Kim, Young Ju; Hong, In Soo; Kim, Myung Soon; Oh, Jin Hwan; Paik, Seog In [Yonsei Univ. College of Medicine, Wonju (Korea, Republic of)

    1996-01-01

    To investigate the role of 3D imaging in the sinonasal mass. Twenty patients with sinonasal mass(squamous cell carcinoma[n=6], spindle cell carcinoma[n=1], angiomatous polyp[n=1], giant cell reparative granuloma[n=1], non-Hodgkin's lymphjoma[n=1], melanoma[n=1], angiofibroma[n=1], inverted papilloma[n=1]) were studied with spiral CT. Reconstruction of surface rendered 3D images and segmentations were performed and compared with the 2D image. The 3D images enabled easy understanding of the characteristics of the mass in 12 casese. The 3D images displayed pathway of tumor extension in 5 cases and were helpful in assessing the primary site of the mass in 3 cases. In two cases with encasement of ICA by the mass, assessment of relationship between the mass and vessels were possible through the segmentation. The 3D image, as an adjunct to the 2D image, can help to evaluate the virtual appearance of bony change, the degree of extension of mass, the spreading route, the evaluation of origin site. It also provides valuable 3-dimensional conception of the mass, especially for the surgeon.

  8. Atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry of friction modifier additives analyzed directly from base oil solutions.

    Science.gov (United States)

    Widder, Lukas; Brennerb, Josef; Huttera, Herbert

    2014-01-01

    To develop new products and to apply measures of quality control quick and simple accessibility of additive composition in automo- tive lubrication is important. The aim of this study was to investigate the possibility of analyzing organic friction modifier additives by means of atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry [AP-MALDI-MS] from lubricant solu- tions without the use of additional separation techniques. Analyses of selected friction modifier ethoxylated tallow amines and oleic acid amide were compared using two ionization methods, positive-ion electrospray ionization (ESI) and AP-MALDI, using a LTQ Orbitrap mass spectrometer. Pure additives were characterized from solvent solutions, as well as from synthetic and mineral base oil mixtures. Detected ions of pure additive samples consisted mainly of [M + H]+, but also alkaLi metal adducts [M + Na]+ and [M + K]+ could be seen. Characterizations of blends of both friction modifiers from the base oil mixtures were carried out as well and showed significant inten- sities for several additive peaks. Thus, this work shows a method to directly analyze friction modifier additives used in the automotive industry from an oil blend via the use of AP-MALDI without any further separation steps. The method presented will further simplify the acquisition of data on lubricant composition and additives. Furthermore, it allows the perspective of analyzing additive reaction products directly from formulated oil blends.

  9. Performance Evaluation of the Sysmex CS-5100 Automated Coagulation Analyzer.

    Science.gov (United States)

    Chen, Liming; Chen, Yu

    2015-01-01

    Coagulation testing is widely applied clinically, and laboratories increasingly demand automated coagulation analyzers with short turn-around times and high-throughput. The purpose of this study was to evaluate the performance of the Sysmex CS-5100 automated coagulation analyzer for routine use in a clinical laboratory. The prothrombin time (PT), international normalized ratio (INR), activated partial thromboplastin time (APTT), fibrinogen (Fbg), and D-dimer were compared between the Sysmex CS-5100 and Sysmex CA-7000 analyzers, and the imprecision, comparison, throughput, STAT function, and performance for abnormal samples were measured in each. The within-run and between-run coefficients of variation (CV) for the PT, APTT, INR, and D-dimer analyses showed excellent results both in the normal and pathologic ranges. The correlation coefficients between the Sysmex CS-5100 and Sysmex CA-7000 were highly correlated. The throughput of the Sysmex CS-5100 was faster than that of the Sysmex CA-7000. There was no interference at all by total bilirubin concentrations and triglyceride concentrations in the Sysmex CS-5100 analyzer. We demonstrated that the Sysmex CS-5100 performs with satisfactory imprecision and is well suited for coagulation analysis in laboratories processing large sample numbers and icteric and lipemic samples.

  10. An evaluation of gastric mass survey from the standpoint of expectation of life

    International Nuclear Information System (INIS)

    Yokoyama, Michio; Kitabatake, Takashi.

    1977-01-01

    The authors reexamined the evaluation of mass gastric survey, which had previously been reported by them, from the standpoint of expectation of life and advocated new theories, the number of years of expected lifesaving and the rate of loss and gain of years. Comparison between the new evaluation and the pre-existing evaluation produces the following differences. (1) The number of years of expected lifesaving increases rapidly from the 50s to reach a peak in the 60s and to decrease from the 70s. This is more realistic and reasonable than the pre-existing method by which the higher the age, the more is gain increased. (2) The rate of loss and gain of mass gastric survey increases in each age group. In other words, the value of mass gastric survey is evaluated more highly. While the importance of mass gastric survey has recently been recognized, the number of examinees increasing, injury due to exposure to radiation has become a serious problem. Therefore, it was thought to be important to perform mass gastric survey efficiently on subjects limited based on the theory investigated from both aspects of advantage and disadvantage. (Chiba, N.)

  11. Evaluation of a mass media campaign promoting using help to quit smoking.

    Science.gov (United States)

    Gibson, Laura A; Parvanta, Sarah A; Jeong, Michelle; Hornik, Robert C

    2014-05-01

    Although there is evidence that promoting individual cessation aids increases their utilization, mass media campaigns highlighting the benefit of using help to quit have not been evaluated. The effects of a Philadelphia adult smoking-cessation media campaign targeting using help in ad taglines were analyzed from March to November 2012. This study distinctively analyzed the campaign's impact at both the population level (effects on the average person) and the individual level (effects among those who reported exposure). The 16-month mass media campaign aired in Philadelphia PA from December 2010 to March 2012. A representative sample of adult Philadelphia smokers was interviewed by telephone at baseline (n=491) and new samples were interviewed monthly throughout the campaign (n=2,786). In addition, a subsample of these respondents was reinterviewed 3 months later (n=877). On average, participants reported seeing campaign ads four times per week. Among individual respondents, each additional campaign exposure per week increased the likelihood of later reporting using help (OR=1.08, p<0.01), adjusting for baseline use of help and other potential confounders. This corresponded to a 5% increase in the use of help for those with average exposure relative to those with no exposure. Cross-sectional associations between individual campaign exposure and intentions to use help were consistent with these lagged findings. However, there was no evidence of population-level campaign effects on use of help. Although the campaign was effective at the individual level, its effects were too small to have a population-detectable impact. Copyright © 2014 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  12. A Java-platform software for the evaluation of mass attenuation and ...

    African Journals Online (AJOL)

    A computer software was written for the evaluation of mass attenuation coefficient (μ/ρ) and mass energy-absorption coefficient (μ /ρ) for body tissues and substitutes of arbitrary elemental composition and en percentage-by-weight of elemental constituents using the Java development platform which could run on any ...

  13. Evaluation of mass distribution data from 252Cf spontaneous fission

    International Nuclear Information System (INIS)

    Liu Tingjin

    2003-01-01

    The mass distribution data of 252 Cf spontaneous fission were evaluated based on 7 sets of available experimental data. The measured data were corrected for the standards and γ intensity used by using the new evaluated ones. The errors were made necessary adjusting. The evaluated experimental data were fitted with spline function without any restriction and with symmetric restriction. These two sets of fit data were recommended as reference data of the mass distribution of 252 Cf spontaneous fission. The errors of the recommended data were considerably reduced comparing with the measured ones. The light and heavy peaks are not completely symmetric. Also there are fine structures on the right side of the light peak at A=109-111 and left side of the heavy peak at A=137-139. These should be paid attention and studied further. (author)

  14. Evaluation difference between mass of received cargo and mass of handed over the cargo in the determination of the masses by draft survey

    Directory of Open Access Journals (Sweden)

    Yakuta I. V.

    2016-12-01

    Full Text Available The paper provides the analysis of problems associated with the evaluation of difference between the mass of received and handed over cargo in determining the masses by draft survey and due to the difference in the measurement conditions at the loading and unloading ports (due to the change errors in various stages of the measurement procedures. The errors that may arise in determining the mass of the cargo due to roughness when measuring draft, due to using the inclinometer to determine the draft from one of boards, due to instrumental errors in the determination of the density of seawater, due to other possible errors have been investigated and evaluated. To estimate the errors of draft due to heaving and errors of inclinometer some formula are to be applied, their derivation has been done in this paper. It has been recommended to use the traditional formula of high-speed drawdown with the replacement of vessel speed on current rate to calculate the error of precipitation arising from the drawdowns ship on a current. The value per unit displacement draft from loading scale has been used to evaluate the error of the displacement appearing in the presence of draft errors. As a result two similar criteria (rigorous and statistical of allowable discrepancies calculated by draft survey mass of cargo in the port of loading and port of discharge have been substantiated. These criteria require the calculation and accumulation in a table of all the errors and calculate the total error of displacement. Criteria will allow the consignee and the carrier come to a reasonable and agreed decision about the significance of differences of the masses taking into account the indifference of conditions and measuring instruments.

  15. ASDA - Advanced Suit Design Analyzer computer program

    Science.gov (United States)

    Bue, Grant C.; Conger, Bruce C.; Iovine, John V.; Chang, Chi-Min

    1992-01-01

    An ASDA model developed to evaluate the heat and mass transfer characteristics of advanced pressurized suit design concepts for low pressure or vacuum planetary applications is presented. The model is based on a generalized 3-layer suit that uses the Systems Integrated Numerical Differencing Analyzer '85 in conjunction with a 41-node FORTRAN routine. The latter simulates the transient heat transfer and respiratory processes of a human body in a suited environment. The user options for the suit encompass a liquid cooled garment, a removable jacket, a CO2/H2O permeable layer, and a phase change layer.

  16. Resonantly-enhanced two-photon ionization and mass-analyzed threshold ionization (MATI) spectroscopy of 2-hydroxypyridine

    CERN Document Server

    Lee, D H; Choi, K W; Choi, Y S; Kim, S K

    2002-01-01

    Mass-analyzed threshold ionization (MATI) spectra of 2-hydroxypyridines existing as lactims (2-pyridionl) in a molecular beam are obtained via (1+1') two-photon process to give accurate ionization energies of 8.9344 +- 0.0005 and 8.9284 +- 0.0005 eV for 2-pyridinol (2Py-OH) and its deuterated analogue (2Py-OD), respectively. Resonantly-enhanced two-photon ionization spectra of these compounds are also presented to give vibrational structures of their S sub 1 states. Vibrational frequencies of 2Py-OH and 2Py-OD in ionic ground states are accurately determined from MATI spectra taken via various S sub 1 intermediate states, and associated vibrational modes are assigned with the aid of ab initio calculations.

  17. The Orbitrap mass analyzer as a space instrument for the understanding of prebiotic chemistry in the Solar System

    Science.gov (United States)

    Vuitton, Véronique; Briois, Christelle; Makarov, Alexander

    Over the past decade, it has become apparent that organic molecules are widespread in our Solar System and beyond. The better understand of the prebiotic chemistry leading to their formation is a primary objective of many ongoing space missions. Cassini-Huygens revealed the existence of very large molecular structures in Titan's atmosphere as well as on its surface, in the form of dune deposits, but their exact nature remains elusive. One key science goal of the Mars Science Laboratory Curiosity rover is to assess the presence of organics on the red planet. Rosetta will characterize the elemental and isotopic composition of the gas and dust ejected from comet Churyumov-Gerasimenko, while amino acids have been detected in meteorites. This search for complex organics relies heavily on mass spectrometry, which has the remarkable ability to analyze and quantify species from almost any type of sample (provided that the appropriate sampling and ionizing method is used). Because of the harsh constraints of the spatial environment, the mass resolution of the spectrometers onboard current space probes is quite limited compared to laboratory instruments, leading to significant limitations in the scientific return of the data collected. Therefore, future in situ solar system exploration missions would significantly benefit from instruments relying on High Resolution Mass Spectrometry (HRMS). Since 2009, 5 French laboratories (LPC2E, IPAG, LATMOS, LISA, CSNSM) involved in the chemical investigation of solar system bodies form a Consortium to develop HRMS for future space exploration, based on the use of the Orbitrap technology (C. Briois et al., 2014, to be submitted). The work is undertaken in close collaboration with the Thermo Fisher Scientific Company, which commercializes Orbitrap based laboratory instruments. The Orbitrap is an electrostatic mass analyzer, it is compact, lightweight, and can reach a good sensitivity and dynamic range. A prototype is under development at

  18. Sustainability Evaluation of Mass Customization

    DEFF Research Database (Denmark)

    Brunø, Thomas Ditlev; Nielsen, Kjeld; Taps, Stig B.

    2013-01-01

    This paper addresses the issue whether the concepts mass customization and sustainability are fundamentally compatible by asking the question: can a mass customized product be sustainable? Some factors indicate that mass customized products are less sustainable than standardized products; however...... other factors suggest the opposite. This paper explores these factors during three life cycle phases for a product: Production, Use and End of Life. It is concluded that there is not an unambiguous causal relationship between mass customization and sustainability; however several factors unique to mass...... customized products are essential to consider during product development....

  19. The use of mass spectrometry to analyze dried blood spots.

    Science.gov (United States)

    Wagner, Michel; Tonoli, David; Varesio, Emmanuel; Hopfgartner, Gérard

    2016-01-01

    Dried blood spots (DBS) typically consist in the deposition of small volumes of capillary blood onto dedicated paper cards. Comparatively to whole blood or plasma samples, their benefits rely in the fact that sample collection is easier and that logistic aspects related to sample storage and shipment can be relatively limited, respectively, without the need of a refrigerator or dry ice. Originally, this approach has been developed in the sixties to support the analysis of phenylalanine for the detection of phenylketonuria in newborns using bacterial inhibition test. In the nineties tandem mass spectrometry was established as the detection technique for phenylalanine and tyrosine. DBS became rapidly recognized for their clinical value: they were widely implemented in pediatric settings with mass spectrometric detection, and were closely associated to the debut of newborn screening (NBS) programs, as a part of public health policies. Since then, sample collection on paper cards has been explored with various analytical techniques in other areas more or less successfully regarding large-scale applications. Moreover, in the last 5 years a regain of interest for DBS was observed and originated from the bioanalytical community to support drug development (e.g., PK studies) or therapeutic drug monitoring mainly. Those recent applications were essentially driven by improved sensitivity of triple quadrupole mass spectrometers. This review presents an overall view of all instrumental and methodological developments for DBS analysis with mass spectrometric detection, with and without separation techniques. A general introduction to DBS will describe their advantages and historical aspects of their emergence. A second section will focus on blood collection, with a strong emphasis on specific parameters that can impact quantitative analysis, including chromatographic effects, hematocrit effects, blood effects, and analyte stability. A third part of the review is dedicated to

  20. Quality in mass-produced insects: definition and evaluation

    International Nuclear Information System (INIS)

    Chambers, D.L.

    1975-01-01

    The insect that is mass-produced and released in a control programme is in effect a biological bullet, a self-guided missile designed to deliver a beneficial effect against a pest insect. The ability of the released insect to achieve this objective may be influenced in many ways. The control of the quality of mass-produced insects must include an understanding of the behavioural components critical to their success and an evaluation of their performance based upon these behavioural components. The paper discusses some of the principles and techniques being used and developed to study behavioural performance and quality. Included are discussions of tests of: vigour, irritability, activity, sound production, response thresholds, reproductive preference and drive, biotic potential, and others. (author)

  1. COINTOF mass spectrometry: design of a time-of-flight analyzer and development of the analysis method

    International Nuclear Information System (INIS)

    Teyssier, C.

    2012-01-01

    DIAM (Device for the irradiation of molecular clusters) is a newly designed experimental setup to investigate processes resulting from the irradiation of molecular nano-systems by 20-150 keV protons. One of its specificities relies on the original technique of mass spectrometry named COINTOF (Correlated Ion and Neutral Time Of Flight) consisting in correlated measurements of the time of flight of charged and neutral fragments produced by the dissociation of a single molecular ion parent. A strategy of treatment and analysis of the detection signals was developed to distinguish two fragments close in time ( 3 O + and two water molecules. The distribution of the time of flight difference between the two neutral fragments is measured providing an estimate of the kinetic energy release of a few eV. In parallel, a second time-of-flight mass spectrometer was designed. It associates a linear time-of-flight and an orthogonal time-of-flight and integrates position detectors (delay line anode). Simulations demonstrate the potentials of the new analyzer. Finally, research works were led at the laboratory R.-J. A. Levesque (Universite de Montreal) on the imaging capabilities of the multi-pixel detectors of the MPX-ATLAS collaboration. (author)

  2. Instrumentation for mass spectrometry: 1997

    Energy Technology Data Exchange (ETDEWEB)

    McLuckey, S.A.

    1997-08-01

    All mass spectrometry experiments involve the manipulation of material, an interface with the mass spectrometer, ionization, ion manipulation/analysis, detection and data collection/reduction. Each of these elements involve instrumentation. The wide range of species now amenable to mass spectrometry and the diverse areas of physical science in which it plays a role have led to a seemingly unlimited array of instrumental combinations. However, only a limited number of mass analyzers, and their combinations, dominate. The dominant analyzers include time-of-flight, Fourier transform ion cyclotron resonance, the Paul trap, the mass filter, and the sector mass spectrometer. Why there are so few (or so many, depending upon one`s point of view) can be understood upon consideration of a set of mass analyzer figures of merit. These include mass resolution, mass accuracy, mass range, dynamic range, abundance sensitivity, precision, efficiency, speed, MS{sup n} capability, compatibility with the ionizer, cost, and size. The most appropriate form of mass spectrometry is determined by the priorities of the particular measurement placed on the various mass analyzer characteristics and the relative strengths of the analyzers in meeting the requirements. Each of the analyzer types has a unique set of figures of merit that makes it optimally suited for particular applications. This paper discusses these figures of merit, provides data illustrating recent developments for each analyzer type, and gives the figures of merit of each type of analyzer as they stand in 1997. 101 refs., 24 figs.

  3. Isotopic abundance analysis of carbon, nitrogen and sulfur with a combined elemental analyzer-mass spectrometer system

    International Nuclear Information System (INIS)

    Pichlmayer, F.; Blochberger, K.

    1988-01-01

    Stable isotope ratio measurements of carbon, nitrogen and sulfur are of growing interest as analytical tool in many fields of research, but applications were somewhat hindered in the past by the fact that cumbersome sample preparation was necessary. A method has therefore been developed, consisting in essential of coupling an elemental analyzer with an isotope mass spectrometer, enabling fast and reliable conversion of C-, N- and S-compounds in any solid or liquid sample into the measuring gases carbon dioxide, nitrogen and sulfur dioxide for on-line isotopic analysis. The experimental set-up and the main characteristics are described in short and examples of application in environmental research, food analysis and clinical diagnosis are given. (orig.)

  4. Determination of δ13C, δ15N, or δ34S by isotope-ratio-monitoring mass spectrometry using an elemental analyzer

    Science.gov (United States)

    Johnson, Craig A.; Stricker, Craig A.; Gulbransen, Cayce A.; Emmons, Matthew P.

    2018-02-14

    This report describes procedures used in the Geology, Geophysics, and Geochemistry Science Center of the U.S. Geological Survey in Denver, Colorado, to determine the stable-isotope ratios 13C/12C, 15N/14N, and 34S/32S in solid materials. The procedures use elemental analyzers connected directly to gas-source isotope-ratio mass spectrometers. A different elemental–analyzer–mass-spectrometer system is used for 13C/12C and 15N/14N than is used for 34S/32S to accommodate differences in reagents, catalysts, and instrument settings.

  5. Evaluation of automated enzyme immunoassays for five anticonvulsants and theophylline adapted to a centrifugal analyzer.

    Science.gov (United States)

    Urquhart, N; Godolphin, W; Campbell, D J

    1979-05-01

    We report a clinical evaluation of the enzyme immunoassay (EMIT) performed with the GEMSAEC centrifugal analyzer as compared to gas-liquid and liquid chromatography for anticonvulsant drugs and theophylline, respectively. A good correlation was obtained for all drugs, although some difficulties were experienced with one lot of reagent for ethosuximide. The analyzer has an economic advantage if many samples are being analyzed for few drugs in each sample.

  6. [Analyze prescription rules of Professor Jiang Liangduo treatment for abdominal mass based on traditional Chinese medicine inheritance platform].

    Science.gov (United States)

    Lian, Xiao-Xiao; Guo, Xiao-Xia

    2018-01-01

    To investigate the herbal prescription rules of Professor Jiang Liangduo in the treatment of abdominal mass based on the traditional Chinese medicine inheritance support system software (TCMISS) of version 2.5, find out new herbal formulas for the treatment of abdominal mass, and then provide new reference to its traditional Chinese medicine therapy. By the method of retrospective study, one hundred and thirty-two outpatient prescriptions of Professor Jiang for the treatment of abdominal mass were collected to establish a typical database with TCMISS. Four properties, five tastes, channel tropism, frequency count, Chinese herbal prescriptions rules and the new prescriptions were analyzed so as to dig out the prescription rules. There were 57 herbs with a frequency>=15, and then 91 core combinations of 2-5 herbs were evolved and 9 new prescriptions were created. It was found out that these drugs mainly had the effects of liver nourishing and soothing, soft-moist and dredging-tonifying, supporting right and dispeling evil, cooperating with the method of calming the liver and resolving hard lump according to the actual situation. It reflected the thought of treatment based on syndrome differentiation in TCM, and provided a new reference for its clinical treatment and research. Copyright© by the Chinese Pharmaceutical Association.

  7. Evaluation of the DCA Vantage analyzer for HbA 1c assay.

    Science.gov (United States)

    Szymezak, Jean; Leroy, Nathalie; Lavalard, Emmanuelle; Gillery, Philippe

    2008-01-01

    Measurement of HbA 1c is key in monitoring diabetic patients in both laboratories and clinical units, where HbA 1c results are used as part of patient education. We have evaluated the DCA Vantage, a new device for immunological assay of HbA 1c. HbA 1c results obtained were evaluated in terms of precision, linearity, specificity and practicability, and were compared with results obtained by a Variant II HPLC method. The method exhibited intra- and inter-assay coefficients of variation lower than 2.6% and 4.0%, respectively, and good correlation with the comparison HPLC method (r2=0.9776). No interference was noted in the presence of labile HbA 1c or carbamylated hemoglobin. The new device exhibited improved practicability characteristics and allowed better sample identification, better management of quality control routines and greater connectivity possibilities compared to the previous DCA 2000 analyzer. This new analyzer exhibited analytical and practical characteristics very suitable for HbA 1c assay for laboratory or point-of-care use according to good laboratory practice.

  8. Volumetric vs Mass Velocity in Analyzing Convective-Diffusive Transport Processes in Liquids

    Science.gov (United States)

    Brenner, Howard

    2000-11-01

    Because mass rather than volume is preserved in fluid-mechanical problems involving density changes, a natural predilection exists for quantifying convective-diffusive transport phenomena in terms of a velocity field based upon mass, rather than volume. Indeed, in the classic BSL "Transport Phenomena" textbook, but a single reference exists even to the very concept of a volume velocity, and even then it is relegated to a homework assignment. However, especially when dealing with transport in fluids in which the mass density of the conserved property being transported (e.g., chemical species, internal energy, etc.) is independent of the prevailing pressure, as is largely true in the case of liquids, overwhelming advantages exist is preferring the volume velocity over the more ubiquitous and classical mass velocity. In a generalization of ideas pioneered by D. D. Joseph and co-workers, we outline the reasons for this volumetric velocity preference in a broad general context by identifying a large class of physical problems whose solutions are rendered more accessible by exploiting this unconventional velocity choice.

  9. Development and Evaluation of an Adolescents' Depression Ontology for Analyzing Social Data.

    Science.gov (United States)

    Jung, Hyesil; Park, Hyeoun-Ae; Song, Tae-Min

    2016-01-01

    This study aims to develop and evaluate an ontology for adolescents' depression to be used for collecting and analyzing social data. The ontology was developed according to the 'ontology development 101' methodology. Concepts were extracted from clinical practice guidelines and related literatures. The ontology is composed of five sub-ontologies which represent risk factors, sign and symptoms, measurement, diagnostic result and management care. The ontology was evaluated in four different ways: First, we examined the frequency of ontology concept appeared in social data; Second, the content coverage of ontology was evaluated by comparing ontology concepts with concepts extracted from the youth depression counseling records; Third, the structural and representational layer of the ontology were evaluated by 5 ontology and psychiatric nursing experts; Fourth, the scope of the ontology was examined by answering 59 competency questions. The ontology was improved by adding new concepts and synonyms and revising the level of structure.

  10. Development and evaluation of a workpiece temperature analyzer for industrial furnaces

    Energy Technology Data Exchange (ETDEWEB)

    1990-05-01

    An instrument capable of measuring the bulk temperature of a workpiece while it is being heated could have a variety of applications. If such an instrument were reasonably priced, it would have a tremendous impact upon national energy usage. The Department of Energy has realized the importance of this type of instrument and has sponsored three concurrent programs to evaluate three different technologies for this type of instrument. In one of these programs, Surface Combustion is the prime contractor to develop a pulsed laser, polarizing interferometer based sensor to be used as a workpiece temperature analyzer (WPTA). The overall goal of the program is to develop a workpiece temperature analyzer for industrial furnaces to significantly improve product quality, productivity and energy efficiency. The workpiece temperature analyzer concept in this program uses a pulsed laser polarizing interferometer (PLPI) for measuring sound velocity through a workpiece. This type of instrument has a high resolution and could detect surface motion of as small as 10 picometer. The sound velocity measurement can be converted to an average workpiece temperature through a mathematical equation programmed into the microprocessor used for control. 76 refs., 12 figs., 14 tabs.

  11. Evaluation of bromide mass discharge in a sandy aquifer at Vandenberg AFB, CA

    Science.gov (United States)

    Mackay, D. M.; Rasa, E.; Einarson, M.; Kaiser, P.; Chakraborty, I.; Scow, K. M.

    2009-12-01

    Side-by-side experiments were conducted by UC Davis research team at a former fuel station at Vandenberg Air Force Base (AFB) to evaluate the rate of transformation of methyl tert-butyl ether (MTBE) to tert-butyl alcohol (TBA) impacted by ethanol and to investigate evidence of TBA degradation under sulfate reducing conditions. On one side we injected groundwater amended with ethanol and MTBE. In the other lane we injected groundwater amended with TBA. On both sides, injected ground water was spiked with bromide tracer to provide estimates of groundwater flow direction variations, flow velocity, dispersion, and mobile mass loss resulting from diffusive sequestration into aquitards. 162 monitoring wells were aligned into seven transects located downgradient of the injection wells. The mass discharge approach was used to evaluate the natural attenuation of the injected constituents. In this talk we will focus on calculations of mass discharge of the bromide tracer at each of the seven monitoring well transects. The amount of bromide mass discharged through each transect was calculated for any sampling time using field measurements of break through curves. Cumulative mass discharges were estimated and, by iteration based on mass balance, the flow properties of the aquifer were estimated. The calibration process resulted in subtle but quantitatively important changes in our assumptions regarding key physical properties of the aquifer (thickness, porosity) which could be only approximately estimated by standard methods (coring, CPT, etc.). On the basis of this calibration, a more robust approach was devised for evaluating the source and fate of TBA in the aquifer.

  12. Application of sonoelastography: Comparison of performance between mass and non-mass lesion

    International Nuclear Information System (INIS)

    Ko, Eun Sook; Choi, Hye Young; Kim, Rock Bum; Noh, Woo-Chul

    2012-01-01

    Objectives: The purpose of this study was to determine the performance of the conventional ultrasonography (US) and sonoelastography (SE) in three conditions of all lesions, confined to mass, and confined to non-mass lesion and to compare the performance of each modality between mass and non-mass lesion. Materials and methods: A total 364 patients with 375 lesions were evaluated with US and subsequently SE before performing US-guided biopsy. Two radiologists retrospectively analyzed conventional US and elasticity images by consensus. The US findings were classified as mass or non-mass lesion. With final pathology as reference, in each case of all lesions, masses, and non-mass lesions, areas under the ROC curves (Az) were calculated and compared for the two techniques. The comparison of Az values between the curves for US and SE, and between the curves for mass and non-mass lesion was performed. Results: Among 375 lesions, 104 (28%) lesions were malignant and 271 (72%) lesions were benign. 36 (9.6%) of 375 lesions were classified as non-mass lesion at US. There were statistically significant difference of performance between US and SE in cases of all lesion (p = 0.003) and mass (p = 0.023). However, there was no statistically significant difference of performance in case of non-mass lesion (p = 0.5). Comparisons of the Az values of US and SE between mass and non-mass lesions were not statistically significant (p = 0.745, p = 0.415, respectively). Conclusion: There was no statistically significant difference of performance of US and SE between mass and non-mass lesion.

  13. Objective evaluation of analyzer performance based on a retrospective meta-analysis of instrument validation studies: point-of-care hematology analyzers.

    Science.gov (United States)

    Cook, Andrea M; Moritz, Andreas; Freeman, Kathleen P; Bauer, Natali

    2017-06-01

    Information on quality requirements and objective evaluation of performance of veterinary point-of-care analyzers (POCAs) is scarce. The study was aimed at assessing observed total errors (TE obs s) for veterinary hematology POCAs via meta-analysis and comparing TE obs to allowable total error (TE a ) specifications based on experts' opinions. The TE obs for POCAs (impedance and laser-based) was calculated based on data from instrument validation studies published between 2006 and 2013 as follows: TE obs = 2 × CV [%] + bias [%]. The CV was taken from published studies; the bias was estimated from the regression equation at 2 different concentration levels of measurands. To fulfill quality requirements, TE obs should be 60% of analyzers showed TE obs hematology variables, respectively. For the CBC, TE obs was TE a (data from 3 analyzers). This meta-analysis is considered a pilot study. Experts' requirements (TE obs < TE a ) were fulfilled for most measurands except HGB (due to instrument-related bias for the ADVIA 2120) and platelet counts. Available data on the WBC differential count suggest an analytic bias, so nonstatistical quality control is recommended. © 2017 American Society for Veterinary Clinical Pathology.

  14. Evaluation of the i-STAT point-of-care analyzer in critically ill adult patients.

    Science.gov (United States)

    Steinfelder-Visscher, Jacoline; Teerenstra, Steven; Gunnewiek, Jacqueline M T Klein; Weerwind, Patrick W

    2008-03-01

    Point-of-care analyzers may benefit therapeutic decision making by reducing turn-around-time for samples. This is especially true when biochemical parameters exceed the clinical reference range, in which acute and effective treatment is essential. We therefore evaluated the analytical performance of the i-STAT point-of-care analyzer in two critically ill adult patient populations. During a 3-month period, 48 blood samples from patients undergoing cardiac surgery with cardiopulmonary bypass (CPB) and 42 blood samples from non-cardiac patients who needed intensive care treatment were analyzed on both the i-STAT analyzer (CPB and non-CPB mode, respectively) and our laboratory analyzers (RapidLab 865/Sysmex XE-2100 instrument). The agreement analysis for quantitative data was used to compare i-STAT to RapidLab for blood gas/electrolytes and for hematocrit with the Sysmex instrument. Point-of-care electrolytes and blood gases had constant deviation, except for pH, pO2, and hematocrit. A clear linear trend in deviation of i-STAT from RapidLab was noticed for pH during CPB (r = 0.32, p = .03) and for pO2 > 10 kPa during CPB (r = -0.59, p pO2 pO2 pO2 range (10.6 pO2 range below 25% (n = 11) using the i-STAT. The i-STAT analyzer is suitable for point-of-care testing of electrolytes and blood gases in critically ill patients, except for high pO2. However, the discrepancy in hematocrit bias shows that accuracy established in one patient population cannot be automatically extrapolated to other patient populations, thus stressing the need for separate evaluation.

  15. Mass size and occurrence of necrosis as discerning values to distinguish between a malignant mass and a bening one by CT. Adrenal mass as the only clinicoradiologic finding

    International Nuclear Information System (INIS)

    Rodriguez Gonzalez, R.

    1991-01-01

    We have studied 123 adult patients with 137 adrenal masses, analyzing mass size and ocurrence of necrosis. We have proved that necrosis depends, although not perfectly, on the mass size. Though 81-83% of masses lasser than 3-4 cm are bening, size alone has no a great discerning value to distinguish between a malignant mass and a bening one, other clinical and radiologic data being more decisive. In 37 patients, with 38 adrenal masses, there was no other findings which could information on the type of treatment to choose. From the adrenal masses of these last patients we carried out a diagnostic efficiency curve (DEC) which showed that the critical size in order to distinguish between a bening mass and a malignant one could be 5 cm. After an evaluation of the results obtained in the 137 adrenal masses, we think that is wiser to choose a critical size of 4 cm to establish an acting strategy in the patients with an adrenal mass as the only clinicoradiologic finding. (Author)

  16. Ages of young star clusters, massive blue stragglers, and the upper mass limit of stars: Analyzing age-dependent stellar mass functions

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, F. R. N.; Izzard, R. G.; Langer, N.; Stolte, A.; Hußmann, B. [Argelander-Institut für Astronomie der Universität Bonn, Auf dem Hügel 71, D-53121 Bonn (Germany); De Mink, S. E. [Observatories of the Carnegie Institution for Science, 813 Santa Barbara St, Pasadena, CA 91101 (United States); De Koter, A.; Sana, H. [Astronomical Institute " Anton Pannekoek" , Amsterdam University, Science Park 904, 1098 XH, Amsterdam (Netherlands); Gvaramadze, V. V. [Sternberg Astronomical Institute, Lomonosov Moscow State University, Universitetskij Pr. 13, Moscow 119992 (Russian Federation); Liermann, A., E-mail: fschneid@astro.uni-bonn.de [Max Planck Institut für Radioastronomie, Auf dem Hügel 69, D-53121 Bonn (Germany)

    2014-01-10

    Massive stars rapidly change their masses through strong stellar winds and mass transfer in binary systems. The latter aspect is important for populations of massive stars as more than 70% of all O stars are expected to interact with a binary companion during their lifetime. We show that such mass changes leave characteristic signatures in stellar mass functions of young star clusters that can be used to infer their ages and to identify products of binary evolution. We model the observed present-day mass functions of the young Galactic Arches and Quintuplet star clusters using our rapid binary evolution code. We find that the shaping of the mass function by stellar wind mass loss allows us to determine the cluster ages as 3.5 ± 0.7 Myr and 4.8 ± 1.1 Myr, respectively. Exploiting the effects of binary mass exchange on the cluster mass function, we find that the most massive stars in both clusters are rejuvenated products of binary mass transfer, i.e., the massive counterpart of classical blue straggler stars. This resolves the problem of an apparent age spread among the most luminous stars exceeding the expected duration of star formation in these clusters. We perform Monte Carlo simulations to probe stochastic sampling, which support the idea of the most massive stars being rejuvenated binary products. We find that the most massive star is expected to be a binary product after 1.0 ± 0.7 Myr in Arches and after 1.7 ± 1.0 Myr in Quintuplet. Today, the most massive 9 ± 3 stars in Arches and 8 ± 3 in Quintuplet are expected to be such objects. Our findings have strong implications for the stellar upper mass limit and solve the discrepancy between the claimed 150 M {sub ☉} limit and observations of four stars with initial masses of 165-320 M {sub ☉} in R136 and of supernova 2007bi, which is thought to be a pair-instability supernova from an initial 250 M {sub ☉} star. Using the stellar population of R136, we revise the upper mass limit to values in the range

  17. Ages of young star clusters, massive blue stragglers, and the upper mass limit of stars: Analyzing age-dependent stellar mass functions

    International Nuclear Information System (INIS)

    Schneider, F. R. N.; Izzard, R. G.; Langer, N.; Stolte, A.; Hußmann, B.; De Mink, S. E.; Anton Pannekoek, Amsterdam University, Science Park 904, 1098 XH, Amsterdam (Netherlands))" data-affiliation=" (Astronomical Institute Anton Pannekoek, Amsterdam University, Science Park 904, 1098 XH, Amsterdam (Netherlands))" >De Koter, A.; Anton Pannekoek, Amsterdam University, Science Park 904, 1098 XH, Amsterdam (Netherlands))" data-affiliation=" (Astronomical Institute Anton Pannekoek, Amsterdam University, Science Park 904, 1098 XH, Amsterdam (Netherlands))" >Sana, H.; Gvaramadze, V. V.; Liermann, A.

    2014-01-01

    Massive stars rapidly change their masses through strong stellar winds and mass transfer in binary systems. The latter aspect is important for populations of massive stars as more than 70% of all O stars are expected to interact with a binary companion during their lifetime. We show that such mass changes leave characteristic signatures in stellar mass functions of young star clusters that can be used to infer their ages and to identify products of binary evolution. We model the observed present-day mass functions of the young Galactic Arches and Quintuplet star clusters using our rapid binary evolution code. We find that the shaping of the mass function by stellar wind mass loss allows us to determine the cluster ages as 3.5 ± 0.7 Myr and 4.8 ± 1.1 Myr, respectively. Exploiting the effects of binary mass exchange on the cluster mass function, we find that the most massive stars in both clusters are rejuvenated products of binary mass transfer, i.e., the massive counterpart of classical blue straggler stars. This resolves the problem of an apparent age spread among the most luminous stars exceeding the expected duration of star formation in these clusters. We perform Monte Carlo simulations to probe stochastic sampling, which support the idea of the most massive stars being rejuvenated binary products. We find that the most massive star is expected to be a binary product after 1.0 ± 0.7 Myr in Arches and after 1.7 ± 1.0 Myr in Quintuplet. Today, the most massive 9 ± 3 stars in Arches and 8 ± 3 in Quintuplet are expected to be such objects. Our findings have strong implications for the stellar upper mass limit and solve the discrepancy between the claimed 150 M ☉ limit and observations of four stars with initial masses of 165-320 M ☉ in R136 and of supernova 2007bi, which is thought to be a pair-instability supernova from an initial 250 M ☉ star. Using the stellar population of R136, we revise the upper mass limit to values in the range 200-500 M ☉ .

  18. Ages of Young Star Clusters, Massive Blue Stragglers, and the Upper Mass Limit of Stars: Analyzing Age-dependent Stellar Mass Functions

    Science.gov (United States)

    Schneider, F. R. N.; Izzard, R. G.; de Mink, S. E.; Langer, N.; Stolte, A.; de Koter, A.; Gvaramadze, V. V.; Hußmann, B.; Liermann, A.; Sana, H.

    2014-01-01

    Massive stars rapidly change their masses through strong stellar winds and mass transfer in binary systems. The latter aspect is important for populations of massive stars as more than 70% of all O stars are expected to interact with a binary companion during their lifetime. We show that such mass changes leave characteristic signatures in stellar mass functions of young star clusters that can be used to infer their ages and to identify products of binary evolution. We model the observed present-day mass functions of the young Galactic Arches and Quintuplet star clusters using our rapid binary evolution code. We find that the shaping of the mass function by stellar wind mass loss allows us to determine the cluster ages as 3.5 ± 0.7 Myr and 4.8 ± 1.1 Myr, respectively. Exploiting the effects of binary mass exchange on the cluster mass function, we find that the most massive stars in both clusters are rejuvenated products of binary mass transfer, i.e., the massive counterpart of classical blue straggler stars. This resolves the problem of an apparent age spread among the most luminous stars exceeding the expected duration of star formation in these clusters. We perform Monte Carlo simulations to probe stochastic sampling, which support the idea of the most massive stars being rejuvenated binary products. We find that the most massive star is expected to be a binary product after 1.0 ± 0.7 Myr in Arches and after 1.7 ± 1.0 Myr in Quintuplet. Today, the most massive 9 ± 3 stars in Arches and 8 ± 3 in Quintuplet are expected to be such objects. Our findings have strong implications for the stellar upper mass limit and solve the discrepancy between the claimed 150 M ⊙ limit and observations of four stars with initial masses of 165-320 M ⊙ in R136 and of supernova 2007bi, which is thought to be a pair-instability supernova from an initial 250 M ⊙ star. Using the stellar population of R136, we revise the upper mass limit to values in the range 200-500 M ⊙.

  19. Performance evaluation of the Sysmex® XE-2100D automated hematology analyzer

    Directory of Open Access Journals (Sweden)

    Tavany Elisa Santos Maciel

    2014-02-01

    Full Text Available Introduction: The Sysmex® XE-2100D is a multiparameter hematology analyzer designed for hematology testing in samples with ethylenediamine tetraacetic acid (EDTA. Objectives: Considering the importance of this hematology analyzer for clinical and laboratory practice, the objective of this study was to evaluate its analytical performance, comparing the obtained results with quality specifications described in literature. Material and method: In the evaluation of analytical performance, according to recommendations of the document H26-A2 of the Clinical and Laboratory Standards Institute (CLSI, intra-run imprecision, inter-run imprecision, linearity, carryover, autosampler evaluation, clinical sensitivity of the atypical lymphocytes flag (n = 400 samples were included, as well as the comparison between automated and manual leukocyte differential count (n = 400 samples, based on an adaptation of the document H20-A2 of CLSI. Results: Repeatability, reproducibility, linearity and carryover were satisfactory according to the manufacturer's specifications. The clinical sensitivity of the atypical lymphocytes flag showed efficiency, sensitivity and specificity of 92.5%, 65.2% and 94.1% respectively. The correlation coefficients between the automated and manual differential counts of neutrophils, lymphocytes, monocytes, eosinophils and basophils were 0.991, 0.99, 0.872, 0.974 and 0.557, respectively. Conclusions: The results were in accordance with quality specifications described in literature, indicating reliability in Sysmex® XE-2100D. This fact ensures certainty to both laboratory professionals and medical staff. We conclude that the Sysmex® XE-2100D showed excellent analytical performance, and is useful to provide reliable hematology data.

  20. Fetal MRI evaluation of an intracranial mass: in utero evolution of hemorrhage

    International Nuclear Information System (INIS)

    Emamian, Seyed A.; Bulas, Dorothy I.; Vezina, Gilbert L.; Dubovsky, Elizabeth C.; Cogan, Phillip

    2002-01-01

    The role of MRI in the evaluation of fetal abnormalities is still under evaluation. We describe a case of an intracranial mass that was initially identified by prenatal ultrasound and was further evaluated by MRI. Ultimately, the findings were most consistent with hematoma secondary to an underlying dural malformation with spontaneous involution. The advantages of fetal MRI in the assessment and management of this abnormality will be discussed. (orig.)

  1. Fetal MRI evaluation of an intracranial mass: in utero evolution of hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Emamian, Seyed A.; Bulas, Dorothy I.; Vezina, Gilbert L.; Dubovsky, Elizabeth C. [Department of Diagnostic Imaging and Radiology, Children' s National Medical Center, 111 Michigan Avenue, NW, Washington, DC 20010 (United States); Cogan, Phillip [Department of Neurosurgery, Children' s National Medical Center, George Washington University,Washington, DC (United States)

    2002-08-01

    The role of MRI in the evaluation of fetal abnormalities is still under evaluation. We describe a case of an intracranial mass that was initially identified by prenatal ultrasound and was further evaluated by MRI. Ultimately, the findings were most consistent with hematoma secondary to an underlying dural malformation with spontaneous involution. The advantages of fetal MRI in the assessment and management of this abnormality will be discussed. (orig.)

  2. Evaluation of corneal biomechanical properties following penetrating keratoplasty using ocular response analyzer

    Directory of Open Access Journals (Sweden)

    Vanathi Murugesan

    2014-01-01

    Full Text Available Purpose: To evaluate corneal biomechanical properties in eyes that has undergone penetrating keratoplasty (PK. Materials and Methods: Retrospective observational study in a tertiary care centre. Data recorded included ocular response analyzer (ORA values of normal and post-keratoplasty eyes [corneal hysteresis (CH, corneal resistance factor (CRF, Goldmann-correlated intraocular pressure (IOPg, and cornea-compensated intraocular pressure (IOPcc], corneal topography, and central corneal thickness (CCT. Wilcoxon signed rank test was used to analyze the difference in ORA parameter between post-PK eyes and normal eyes. Correlation between parameters was evaluated with Spearman′s rho correlation. Results: The ORA study of 100 eyes of 50 normal subjects and 54 post-keratoplasty eyes of 51 patients showed CH of 8.340 ± 1.85 and 9.923 ± 1.558, CRF of 8.846 ± 2.39 and 9.577 ± 1.631 in post-PK eyes and normal eyes, respectively. CH and CRF did not correlate with post-keratoplasty astigmatism (P = 0.311 and 0.276, respectively while a significant correlation was observed with IOPg (P = 0.004 and IOPcc (P < 0.001. Conclusion: Biomechanical profiles were significantly decreased in post-keratoplasty eyes with significant correlation with higher IOP as compared with that in normal eyes.

  3. Evaluation of Long-term Performance of Enhanced Anaerobic Source Zone Bioremediation using mass flux

    Science.gov (United States)

    Haluska, A.; Cho, J.; Hatzinger, P.; Annable, M. D.

    2017-12-01

    Chlorinated ethene DNAPL source zones in groundwater act as potential long term sources of contamination as they dissolve yielding concentrations well above MCLs, posing an on-going public health risk. Enhanced bioremediation has been applied to treat many source zones with significant promise, but long-term sustainability of this technology has not been thoroughly assessed. This study evaluated the long-term effectiveness of enhanced anaerobic source zone bioremediation at chloroethene contaminated sites to determine if the treatment prevented contaminant rebound and removed NAPL from the source zone. Long-term performance was evaluated based on achieving MCL-based contaminant mass fluxes in parent compound concentrations during different monitoring periods. Groundwater concertation versus time data was compiled for 6-sites and post-remedial contaminant mass flux data was then measured using passive flux meters at wells both within and down-gradient of the source zone. Post-remedial mass flux data was then combined with pre-remedial water quality data to estimate pre-remedial mass flux. This information was used to characterize a DNAPL dissolution source strength function, such as the Power Law Model and the Equilibrium Stream tube model. The six-sites characterized for this study were (1) Former Charleston Air Force Base, Charleston, SC; (2) Dover Air Force Base, Dover, DE; (3) Treasure Island Naval Station, San Francisco, CA; (4) Former Raritan Arsenal, Edison, NJ; (5) Naval Air Station, Jacksonville, FL; and, (6) Former Naval Air Station, Alameda, CA. Contaminant mass fluxes decreased for all the sites by the end of the post-treatment monitoring period and rebound was limited within the source zone. Post remedial source strength function estimates suggest that decreases in contaminant mass flux will continue to occur at these sites, but a mass flux based on MCL levels may never be exceeded. Thus, site clean-up goals should be evaluated as order

  4. Intrahepatic and hilar mass-forming cholangiocarcinoma: Qualitative and quantitative evaluation with diffusion-weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fattach, Hassan El, E-mail: hassangreenmed@gmail.com [Department of Abdominal Imaging, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, 2 rue Ambroise Paré, 75010 Paris (France); Dohan, Anthony, E-mail: anthony.dohan@lrb.aphp.fr [Department of Abdominal Imaging, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, 2 rue Ambroise Paré, 75010 Paris (France); Université Paris-Diderot, Sorbonne Paris Cité, 10 Avenue de Verdun, 75010 Paris (France); UMR INSERM 965-Paris 7 “Angiogenèse et recherche translationnelle”, 2 rue Amboise Paré, 75010 Paris (France); Guerrache, Youcef, E-mail: docyoucef05@yahoo.fr [Department of Abdominal Imaging, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, 2 rue Ambroise Paré, 75010 Paris (France); Dautry, Raphael, E-mail: raphael.dautry@lrb.aphp.fr [Department of Abdominal Imaging, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, 2 rue Ambroise Paré, 75010 Paris (France); Université Paris-Diderot, Sorbonne Paris Cité, 10 Avenue de Verdun, 75010 Paris (France); and others

    2015-08-15

    Highlights: • DW-MR imaging helps depicts all intrahepatic or hilar mass-forming cholangiocarcinomas. • DW-MRI provides best conspicuity of intrahepatic or hilar mass-forming cholangiocarcinomas than the other MRI sequences (P < 0.001). • The use of normalized ADC using the liver as reference organ results in the most restricted distribution of ADC values of intrahepatic or hilar mass-forming cholangiocarcinomas (variation coefficient = 16.6%). - Abstract: Objective: To qualitatively and quantitatively analyze the presentation of intrahepatic and hilar mass-forming cholangiocarcinoma with diffusion-weighted magnetic resonance imaging (DW-MRI). Materials and methods: Twenty-eight patients with histopathologically proven mass-forming cholangiocarcinoma (hilar, n = 17; intrahepatic, n = 11) underwent hepatic DW-MRI at 1.5-T using free-breathing acquisition and three b-values (0,400,800 s/mm{sup 2}). Cholangiocarcinomas were evaluated qualitatively using visual analysis of DW-MR images and quantitatively with conventional ADC and normalized ADC measurements using liver and spleen as reference organs. Results: All cholangiocarcinomas (28/28; 100%) were visible on DW-MR images. DW-MRI yielded best conspicuity of cholangiocarcinomas than the other MRI sequences (P < 0.001). Seven cholangiocarcinomas (7/11; 64%) showed hypointense central area on DW-MR images. Conventional ADC value of cholangiocarcinomas (1.042 × 10{sup −3} mm{sup 2}/s ± 0.221 × 10{sup −3} mm{sup 2}/s; range: 0.616 × 10{sup −3} mm{sup 2}/s to 2.050 × 10{sup −3} mm{sup 2}/s) was significantly lower than that of apparently normal hepatic parenchyma (1.362 × 10{sup −3} mm{sup 2}/s ± 0.187 × 10{sup −3} mm{sup 2}/s) (P < 0.0001), although substantial overlap was found. No significant differences in ADC and normalized ADC values were found between intrahepatic and hilar cholangiocarcinomas. The use of normalized ADC using the liver as reference organ resulted in the most restricted

  5. Intrahepatic and hilar mass-forming cholangiocarcinoma: Qualitative and quantitative evaluation with diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Fattach, Hassan El; Dohan, Anthony; Guerrache, Youcef; Dautry, Raphael

    2015-01-01

    Highlights: • DW-MR imaging helps depicts all intrahepatic or hilar mass-forming cholangiocarcinomas. • DW-MRI provides best conspicuity of intrahepatic or hilar mass-forming cholangiocarcinomas than the other MRI sequences (P < 0.001). • The use of normalized ADC using the liver as reference organ results in the most restricted distribution of ADC values of intrahepatic or hilar mass-forming cholangiocarcinomas (variation coefficient = 16.6%). - Abstract: Objective: To qualitatively and quantitatively analyze the presentation of intrahepatic and hilar mass-forming cholangiocarcinoma with diffusion-weighted magnetic resonance imaging (DW-MRI). Materials and methods: Twenty-eight patients with histopathologically proven mass-forming cholangiocarcinoma (hilar, n = 17; intrahepatic, n = 11) underwent hepatic DW-MRI at 1.5-T using free-breathing acquisition and three b-values (0,400,800 s/mm 2 ). Cholangiocarcinomas were evaluated qualitatively using visual analysis of DW-MR images and quantitatively with conventional ADC and normalized ADC measurements using liver and spleen as reference organs. Results: All cholangiocarcinomas (28/28; 100%) were visible on DW-MR images. DW-MRI yielded best conspicuity of cholangiocarcinomas than the other MRI sequences (P < 0.001). Seven cholangiocarcinomas (7/11; 64%) showed hypointense central area on DW-MR images. Conventional ADC value of cholangiocarcinomas (1.042 × 10 −3 mm 2 /s ± 0.221 × 10 −3 mm 2 /s; range: 0.616 × 10 −3 mm 2 /s to 2.050 × 10 −3 mm 2 /s) was significantly lower than that of apparently normal hepatic parenchyma (1.362 × 10 −3 mm 2 /s ± 0.187 × 10 −3 mm 2 /s) (P < 0.0001), although substantial overlap was found. No significant differences in ADC and normalized ADC values were found between intrahepatic and hilar cholangiocarcinomas. The use of normalized ADC using the liver as reference organ resulted in the most restricted distribution of ADC values of cholangiocarcinomas (variation

  6. Evaluation of the i-STAT point-of-care analyzer in critically ill adult patients.

    NARCIS (Netherlands)

    Steinfelder-Visscher, J.; Teerenstra, S.; Klein Gunnewiek, J.M.T.; Weerwind, P.W.

    2008-01-01

    Point-of-care analyzers may benefit therapeutic decision making by reducing turn-around-time for samples. This is especially true when biochemical parameters exceed the clinical reference range, in which acute and effective treatment is essential. We therefore evaluated the analytical performance of

  7. Limited-sequence magnetic resonance imaging in the evaluation of the ultrasonographically indeterminate pelvic mass

    International Nuclear Information System (INIS)

    Chang, S.D.; Cooperberg, P.L.; Wong, A.D.; Llewellyn, P.A.; Bilbey, J.H.

    2004-01-01

    To evaluate the usefulness of limited-sequence magnetic resonance imaging (MRI) in the elucidation of ultrasonographically indeterminate pelvic masses. This study focused only on pelvic masses in which the origin of the mass (uterine v. extrauterine) could not be determined by ultrasonography (US). The origin of a pelvic mass has clinical implications. A mass arising from the uterus is most likely to be a leiomyoma, which is a benign lesion, whereas an extrauterine mass will have a higher likelihood of malignancy and usually requires surgery. Eighty-one female patients whose pelvic mass was of indeterminate origin on US also underwent limited-sequence MRI of the pelvis. Most of the MRI examinations were performed on the same day as the US. Limited-sequence MRI sequences included a quick gradient-echoT 1 -weighted localizer and a fast spin-echoT 2 -weighted sequence. Final diagnoses were established by surgical pathology or by clinical and imaging follow-up. Limited-sequence MRI was helpful in 79 of the 81 cases (98%). Fifty-two of the 81 masses (64%) were leiomyomas. One was a leiomyosarcoma. The extrauterine masses (26/81 [32%]) were identified as 14 ovarian malignancies, 4 endometriomas, 3 dermoids, an ovarian fibroma, an infarcted fibrothecoma, an infarcted hemorrhagic cyst, a sigmoid diverticular abscess and a gastrointestinal stromal tumour of the ileum. In the other 2 cases (2/81 [2%]), the origin of the pelvic mass remained indeterminate. Both of these indeterminate masses showed low signal onT 2 -weighted images and were interpreted as probable leiomyomas. They were not surgically removed but were followed clinically and had a stable course. Limited-sequence MRI is a quick and efficient way to further evaluate ultrasonographically indeterminate pelvic masses. Limited-sequence MRI of the pelvis can suffice, in these cases, without requiring a full MRI examination. (author)

  8. Limited-sequence magnetic resonance imaging in the evaluation of the ultrasonographically indeterminate pelvic mass

    Energy Technology Data Exchange (ETDEWEB)

    Chang, S.D. [Univ. of British Columbia, Vancouver Hospital and Helath Services Centre, Dept. of Radiology, Vancouver, British Columbia (Canada)]. E-mail: schang@vanhosp.bc.ca; Cooperberg, P.L.; Wong, A.D. [Univ. of British Columbia, St. Paul' s Hospital, Dept. of Radiology, Vancouver, British Columbia (Canada); Llewellyn, P.A. [Lion' s Gate Hospital, Dept. of Radiology, North Vancouver, British Columbia (Canada); Bilbey, J.H. [Royal Inland Hospital, Dept. of Radiology, Kamloops, British Columbia (Canada)

    2004-04-01

    To evaluate the usefulness of limited-sequence magnetic resonance imaging (MRI) in the elucidation of ultrasonographically indeterminate pelvic masses. This study focused only on pelvic masses in which the origin of the mass (uterine v. extrauterine) could not be determined by ultrasonography (US). The origin of a pelvic mass has clinical implications. A mass arising from the uterus is most likely to be a leiomyoma, which is a benign lesion, whereas an extrauterine mass will have a higher likelihood of malignancy and usually requires surgery. Eighty-one female patients whose pelvic mass was of indeterminate origin on US also underwent limited-sequence MRI of the pelvis. Most of the MRI examinations were performed on the same day as the US. Limited-sequence MRI sequences included a quick gradient-echoT{sub 1}-weighted localizer and a fast spin-echoT{sub 2}-weighted sequence. Final diagnoses were established by surgical pathology or by clinical and imaging follow-up. Limited-sequence MRI was helpful in 79 of the 81 cases (98%). Fifty-two of the 81 masses (64%) were leiomyomas. One was a leiomyosarcoma. The extrauterine masses (26/81 [32%]) were identified as 14 ovarian malignancies, 4 endometriomas, 3 dermoids, an ovarian fibroma, an infarcted fibrothecoma, an infarcted hemorrhagic cyst, a sigmoid diverticular abscess and a gastrointestinal stromal tumour of the ileum. In the other 2 cases (2/81 [2%]), the origin of the pelvic mass remained indeterminate. Both of these indeterminate masses showed low signal onT{sub 2}-weighted images and were interpreted as probable leiomyomas. They were not surgically removed but were followed clinically and had a stable course. Limited-sequence MRI is a quick and efficient way to further evaluate ultrasonographically indeterminate pelvic masses. Limited-sequence MRI of the pelvis can suffice, in these cases, without requiring a full MRI examination. (author)

  9. Ages of Young Star Clusters, Massive Blue Stragglers, and the Upper Mass Limit of Stars: Analyzing Age-dependent Stellar Mass Functions

    NARCIS (Netherlands)

    Schneider, F.R.N.; Izzard, R.G.; de Mink, S.E.; Langer, N.; Stolte, A.; de Koter, A.; Gvaramadze, V.V.; Huβman, B.; Liermann, A.; Sana, H.

    2014-01-01

    Massive stars rapidly change their masses through strong stellar winds and mass transfer in binary systems. The latter aspect is important for populations of massive stars as more than 70% of all O stars are expected to interact with a binary companion during their lifetime. We show that such mass

  10. Performance of the Linear Ion Trap Mass Spectrometer for the Mars Organic Molecule Analyzer (MOMA) Investigation on the 2018 Exomars Rover

    Science.gov (United States)

    Arevalo, Ricardo, Jr.; Brinckerhoff, William B.; Pinnick, Veronica T.; van Amerom, Friso H. W.; Danell, Ryan M.; Li, Xiang; Getty, Stephanie; Hovmand, Lars; Atanassova, Martina; Mahaffy, Paul R.; hide

    2014-01-01

    The 2018 ExoMars rover mission includes the Mars Organic Molecule Analyzer (MOMA) investigation. MOMA will examine the chemical composition of samples acquired from depths of up to two meters below the martian surface, where organics may be protected from degradation derived from cosmic radiation and/or oxidative chemical reactions. When combined with the complement of instruments in the rover's Pasteur Payload, MOMA has the potential to reveal the presence of a wide range of organics preserved in a variety of mineralogical environments, and to begin to understand the structural character and potential origin of those compounds. The MOMA investigation is led by the Max Planck Institute for Solar System Research (MPS) with the mass spectrometer subsystem provided by NASA GSFC. MOMA's linear ion trap mass spectrometer (ITMS) is designed to analyze molecular composition of: (i) gas evolved from pyrolyzed powder samples and separated in a gas chromatograph; and, (ii) ions directly desorbed from crushed solid samples at Mars ambient pressure, as enabled by a pulsed UV laser system, fast-actuating aperture valve and capillary ion inlet. Breadboard ITMS and associated electronics have been advanced to high end-to-end fidelity in preparation for flight hardware delivery to Germany in 2015.

  11. The Ame2012 atomic mass evaluation. Pt. 2. Tables, graphs and references

    International Nuclear Information System (INIS)

    Wang, M.; Audi, G.; Wapstra, A.H.; Kondev, F.G.; MacCormick, M.; Xu, X.; Pfeiffer, B.

    2012-01-01

    This paper is the second part of the new evaluation of atomic masses, Ame2012. From the results of a least-squares calculation, described in Part I, for all accepted experimental data, we derive here tables and graphs to replace those of Ame2003. The first table lists atomic masses. It is followed by a table of the influences of data on primary nuclides, a table of separation energies and reaction energies, and finally, a series of graphs of separation and decay energies. The last section in this paper lists all references to the input data used in Part I of this Ame2012 and also to the data included in the Nubase2012 evaluation (first paper in this issue). (authors)

  12. Real-time airborne particle analyzer

    Science.gov (United States)

    Reilly, Peter T.A.

    2012-10-16

    An aerosol particle analyzer includes a laser ablation chamber, a gas-filled conduit, and a mass spectrometer. The laser ablation chamber can be operated at a low pressure, which can be from 0.1 mTorr to 30 mTorr. The ablated ions are transferred into a gas-filled conduit. The gas-filled conduit reduces the electrical charge and the speed of ablated ions as they collide and mix with buffer gases in the gas-filled conduit. Preferably, the gas filled-conduit includes an electromagnetic multipole structure that collimates the nascent ions into a beam, which is guided into the mass spectrometer. Because the gas-filled conduit allows storage of vast quantities of the ions from the ablated particles, the ions from a single ablated particle can be analyzed multiple times and by a variety of techniques to supply statistically meaningful analysis of composition and isotope ratios.

  13. Initial evaluation and referral guidelines for management of pelvic/ovarian masses.

    Science.gov (United States)

    Le, Tien; Giede, Christopher; Salem, Shia; Lefebvre, Guylaine; Rosen, Barry; Bentley, James; Kupets, Rachel; Power, Patti; Renaud, Marie-Claude; Bryson, Peter; Davis, Donald B; Lau, Susie; Lotocki, Robert; Senikas, Vyta; Morin, Lucie; Bly, Stephen; Butt, Kimberly; Cargill, Yvonne M; Denis, Nanette; Gagnon, Robert; Hietala-Coyle, Marja Anne; Lim, Kenneth Ian; Ouellet, Annie; Raciot, Maria-Hélène

    2009-07-01

    To optimize the management of adnexal masses and to assist primary care physicians and gynaecologists determine which patients presenting with an ovarian mass with a significant risk of malignancy should be considered for gynaecologic oncology referral and management. Laparoscopic evaluation, comprehensive surgical staging for early ovarian cancer, or tumour debulking for advanced stage ovarian cancer. To optimize conservative versus operative management of women with possible ovarian malignancy and to optimize the involvement of gynaecologic oncologists in planning and delivery of treatment. Published literature was retrieved through searches of PubMed or MEDLINE, CINAHL, and the Cochrane Library, using appropriate controlled vocabulary and key words. Results were restricted to systematic reviews, randomized control trials/controlled clinical trials, and observational studies. Grey (unpublished) literature was identified by searching the web sites of health technology assessment and health technology assessment-related agencies, clinical practice guideline collections, clinical trial registries, and national and international medical specialty societies. 1. Primary care physicians and gynaecologists should always consider the possibility of an underlying ovarian cancer in patients in any age group who present with an adnexal or ovarian mass. (II-2B) 2. Appropriate workup of a perimenopausal or postmenopausal woman presenting with an adnexal mass should include evaluation of symptoms and signs suggestive of malignancy, such as persistent pelvic/abdominal pain, urinary urgency/frequency, increased abdominal size/bloating, and difficulty eating. In addition, CA125 measurement should be considered. (II-2B) 3. Transvaginal or transabdominal ultrasound examination is recommended as part of the initial workup of a complex adnexal/ovarian mass. (II-2B) 4. Ultrasound reports should be standardized to include size and unilateral/bilateral location of the adnexal mass and

  14. COMBINED MAMMOGRAPHIC AND SONOGRAPHIC EVALUATION OF PALPABLE BREAST MASSES

    Directory of Open Access Journals (Sweden)

    Reena Mathur

    2016-10-01

    Full Text Available BACKGROUND Breast diseases are common in females. In developing countries like India, females are unaware of breast pathologies hence they are detected usually in advanced stages. We have studied 100 patients of palpable breast masses presenting to our department and evaluate the role of combined mammographic and sonographic imaging in patients with palpable abnormalities of the breast, which help in decision making by clinician as to lesion go for biopsy or follow up. MATERIALS AND METHODS The study was conducted at Department of Radiodiagnosis J. L.N. Medical College & Associated Groups of Hospitals, Ajmer. We included women equal to or more than 30 years referred to this centre with palpable abnormalities of breast during a period from March 2015 to August 2016. All these women underwent a combined mammographic and sonographic evaluation of breast. RESULTS 50 (50% of the 100 palpable abnormalities had benign assessment, 30 (60% of the benign lesions were visible both on mammography and sonography; 18 (36% of the 50 benign lesions were mammographically occult and identified at sonographic evaluation. 2 lesion was sonographically occult (4% and visualized on mammography. In 14 (14% of the 100 cases, imaging evaluation resulted in a suspicious assessment and all these lesions underwent biopsy and 4 were diagnosed as having malignancy. 36(36% of the 100 palpable abnormalities had negative imaging assessment finding: of these 14 patients underwent biopsy and all had benign findings. The sensitivity and negative predictive value for combined mammographic and sonographic assessment were 100%; the specificity was 78.26%. CONCLUSION Combined use of mammography and sonography plays an important role in the management of palpable breast lesions. It characterizes the palpable mass lesion, avoids unnecessary interventions in which imaging findings are unequivocally benign. Negative findings on combined mammographic and sonographic imaging have very high

  15. Rapid identification of pork for halal authentication using the electronic nose and gas chromatography mass spectrometer with headspace analyzer.

    Science.gov (United States)

    Nurjuliana, M; Che Man, Y B; Mat Hashim, D; Mohamed, A K S

    2011-08-01

    The volatile compounds of pork, other meats and meat products were studied using an electronic nose and gas chromatography mass spectrometer with headspace analyzer (GCMS-HS) for halal verification. The zNose™ was successfully employed for identification and differentiation of pork and pork sausages from beef, mutton and chicken meats and sausages which were achieved using a visual odor pattern called VaporPrint™, derived from the frequency of the surface acoustic wave (SAW) detector of the electronic nose. GCMS-HS was employed to separate and analyze the headspace gasses from samples into peaks corresponding to individual compounds for the purpose of identification. Principal component analysis (PCA) was applied for data interpretation. Analysis by PCA was able to cluster and discriminate pork from other types of meats and sausages. It was shown that PCA could provide a good separation of the samples with 67% of the total variance accounted by PC1. Copyright © 2011 Elsevier Ltd. All rights reserved.

  16. Role of echography in diagnostic dilemma in choroidal masses

    Directory of Open Access Journals (Sweden)

    Kopal N Mithal

    2014-01-01

    Full Text Available Purpose: To evaluate the role of echography in diagnosis and management of a diverse array of choroidal masses. Materials and Methods: Sixty-two cases of clinically suspected choroidal masses were prospectively analyzed with B-scan (10 Hz, A-scan, and ultrasound biomicroscopy (UBM (50 Hz after a meticulous history and ocular examination. Ancillary investigations and systemic evaluation were also done. Results: Based on clinical suspicion, acoustic features, response to treatment, and other ancillary tests combined together, the various masses were differentiated. The cases included in the study were as follows: n = 10 malignant melanomas, n = 16 metastasis and infiltrations, n = 9 hemangioma, n = 7 tuberculoma, n = 8 nonspecific inflammatory masses, n = 2 disciform plaques, n = 4 macular cysts or retinoschisis, n = 2 Coat′s disease, n = 1 melanocytoma, and n = 2 osteomas. Ultrasonography (USG alone could identify n = 51 lesions, while UBM in combination with USG was needed in remaining 11 masses. Conclusion: Standardized echography is an important adjunct in the diagnosis and management of eyes with intraocular masses. A better understanding of the clinicopathological and echographic picture of the diverse lesions can help in detection, differentiation, diagnosis, proposing a therapeutic approach, and also monitoring response to treatment. Echography is essential to evaluate tumors for extrascleral and anterior segment extension.

  17. Development of general-purpose software to analyze the static thermal characteristic of nuclear power plant

    International Nuclear Information System (INIS)

    Nakao, Yoshinobu; Koda, Eiichi; Takahashi, Toru

    2009-01-01

    We have developed the general-purpose software by which static thermal characteristic of the power generation system is analyzed easily. This software has the notable features as follows. It has the new algorithm to solve non-linear simultaneous equations to analyze the static thermal characteristics such as heat and mass balance, efficiencies, etc. of various power generation systems. It has the flexibility for setting calculation conditions. It is able to be executed on the personal computer easily and quickly. We ensured that it is able to construct heat and mass balance diagrams of main steam system of nuclear power plant and calculate the power output and efficiencies of the system. Furthermore, we evaluated various heat recovery measures of steam generator blowdown water and found that this software could be a useful operation aid for planning effective changes in support of power stretch. (author)

  18. Evaluation of water content in rock mass by electromagnetic and resistivity tomography. Denjiha, hiteiko tomography ni yoru ganban no gansui jotai hyoka

    Energy Technology Data Exchange (ETDEWEB)

    Inaba, T; Inoue, M; Matsumoto, K [Kajima Corp., Tokyo (Japan)

    1993-10-31

    As a method to evaluate the rock mass, electromagnetic tomography and resistivity tomography were tested on the original site. The electromagnetic tomography can tomographically analyze the propagation velocity and initial amplitude damping. The resistivity tomography uses a finite element method from the initial resistivity distribution model and finally gives a model which is nearly equal to the actual resistivity distribution. Both the above tomographic analyses can detect the crushed spot as a low velocity, high damping and low resistivity spot. However, the electromagnetic tomography could detect finer structure than the resistivity tomography. The water content of rock mass was evaluated from the damping coefficient which was given by the amplitude damping tomography of electromagnetic wave. If it is compared with the water content which is given by the dielectric constant of velocity tomography, there partially exists discrepancy between both, because the damping coefficient contains information on cracks which disperse and reflect the electromagnetic wave. Between the resistivity and porosity, there exists a known experimental formula, which was satisfied by the presently given resistivity. 9 refs., 10 figs.

  19. Methods of analyzing crude oil

    Science.gov (United States)

    Cooks, Robert Graham; Jjunju, Fred Paul Mark; Li, Anyin; Rogan, Iman S.

    2017-08-15

    The invention generally relates to methods of analyzing crude oil. In certain embodiments, methods of the invention involve obtaining a crude oil sample, and subjecting the crude oil sample to mass spectrometry analysis. In certain embodiments, the method is performed without any sample pre-purification steps.

  20. A System Evaluation Theory Analyzing Value and Results Chain for Institutional Accreditation in Oman

    Science.gov (United States)

    Paquibut, Rene Ymbong

    2017-01-01

    Purpose: This paper aims to apply the system evaluation theory (SET) to analyze the institutional quality standards of Oman Academic Accreditation Authority using the results chain and value chain tools. Design/methodology/approach: In systems thinking, the institutional standards are connected as input, process, output and feedback and leads to…

  1. Evaluation of the Air Void Analyzer

    Science.gov (United States)

    2013-07-01

    concrete using image analysis: Petrography of cementitious materials. ASTM STP 1215. S.M. DeHayes and D. Stark, eds. Philadelphia, PA: American...Administration (FHWA). 2006. Priority, market -ready technologies and innovations: Air Void Analyzer. Washington D.C. PDF file. Germann Instruments (GI). 2011...tests and properties of concrete and concrete-making materials. STP 169D. West Conshohocken, PA: ASTM International. Magura, D.D. 1996. Air void

  2. Evaluation of corneal biomechanics in patients with keratectasia following LASIK using dynamic Scheimpflug analyzer.

    Science.gov (United States)

    Ueki, Ryotaro; Maeda, Naoyuki; Fuchihata, Mutsumi; Asai, Tomoko; Koh, Shizuka; Fujimoto, Hisataka; Uematsu, Masafumi; Nishida, Kohji

    2018-04-26

    To investigate the corneal biomechanics in eyes with keratectasia following LASIK using a dynamic Scheimpflug analyzer. Case-Control study. The subjects in the study included 12 eyes with keratectasia after LASIK (KE), 24 eyes with keratoconus (KC), 17 eyes without keratectasia after LASIK (LASIK), and 34 eyes with normal corneas (Normal). Corneal biomechanics of the four groups were evaluated using a dynamic Scheimpflug analyzer. Compared with Normal (7.06 ± 0.54), the radius at the highest concavity (radius, mm) of LASIK (5.96 ± 0.76), KE (4.93 ± 0.61) and KC (5.39 ± 1.02) were significantly small. The Deflection Amplitude (HCDLA, mm) of Normal (0.94 ± 0.07) was significantly lower than those of KE (1.11 ± 0.10) and KC (1.06 ± 0.16), and was not significantly different from that of LASIK (0.98 ± 0.07). There were significant differences between LASIK and KE in radius and HCDLA (P biomechanical features evaluated using the dynamic Scheimpflug analyzer suggest that biomechanical properties in eyes with keratectasia, keratoconus, and LASIK are different from those of normal eyes. Although the biomechanics in eyes with keratectasia differs from that in eyes with LASIK, it is similar to that in eyes with keratoconus.

  3. Neutrino mass as the probe of intermediate mass scales

    International Nuclear Information System (INIS)

    Senjanovic, G.

    1980-01-01

    A discussion of the calculability of neutrino mass is presented. The possibility of neutrinos being either Dirac or Majorana particles is analyzed in detail. Arguments are offered in favor of the Majorana case: the smallness of neutrino mass is linked to the maximality of parity violation in weak interactions. It is shown how the measured value of neutrino mass would probe the existence of an intermediate mass scale, presumably in the TeV region, at which parity is supposed to become a good symmetry. Experimental consequences of the proposed scheme are discussed, in particular the neutrino-less double β decay, where observation would provide a crucial test of the model, and rare muon decays such as μ → eγ and μ → ee anti e. Finally, the embedding of this model in an O(10) grand unified theory is analyzed, with the emphasis on the implications for intermediate mass scales that it offers. It is concluded that the proposed scheme provides a distinct and testable alternative for understanding the smallness of neutrino mass. 4 figures

  4. Neutrino mass as the probe of intermediate mass scales

    Energy Technology Data Exchange (ETDEWEB)

    Senjanovic, G.

    1980-01-01

    A discussion of the calculability of neutrino mass is presented. The possibility of neutrinos being either Dirac or Majorana particles is analyzed in detail. Arguments are offered in favor of the Majorana case: the smallness of neutrino mass is linked to the maximality of parity violation in weak interactions. It is shown how the measured value of neutrino mass would probe the existence of an intermediate mass scale, presumably in the TeV region, at which parity is supposed to become a good symmetry. Experimental consequences of the proposed scheme are discussed, in particular the neutrino-less double ..beta.. decay, where observation would provide a crucial test of the model, and rare muon decays such as ..mu.. ..-->.. e..gamma.. and ..mu.. ..-->.. ee anti e. Finally, the embedding of this model in an O(10) grand unified theory is analyzed, with the emphasis on the implications for intermediate mass scales that it offers. It is concluded that the proposed scheme provides a distinct and testable alternative for understanding the smallness of neutrino mass. 4 figures.

  5. Feasibility evaluation of a neutron grating interferometer with an analyzer grating based on a structured scintillator

    Science.gov (United States)

    Kim, Youngju; Kim, Jongyul; Kim, Daeseung; Hussey, Daniel. S.; Lee, Seung Wook

    2018-03-01

    We introduce an analyzer grating based on a structured scintillator fabricated by a gadolinium oxysulfide powder filling method for a symmetric Talbot-Lau neutron grating interferometer. This is an alternative way to analyze the Talbot self-image of a grating interferometer without using an absorption grating to block neutrons. Since the structured scintillator analyzer grating itself generates the signal for neutron detection, we do not need an additional scintillator screen as an absorption analyzer grating. We have developed and tested an analyzer grating based on a structured scintillator in our symmetric Talbot-Lau neutron grating interferometer to produce high fidelity absorption, differential phase, and dark-field contrast images. The acquired images have been compared to results of a grating interferometer utilizing a typical absorption analyzer grating with two commercial scintillation screens. The analyzer grating based on the structured scintillator enhances interference fringe visibility and shows a great potential for economical fabrication, compact system design, and so on. We report the performance of the analyzer grating based on a structured scintillator and evaluate its feasibility for the neutron grating interferometer.

  6. Feasibility of coupling a thermal/optical carbon analyzer to a quadrupole mass spectrometer for enhanced PM2.5 speciation.

    Science.gov (United States)

    Riggio, Gustavo M; Chow, Judith C; Cropper, Paul M; Wang, Xiaoliang; Yatavelli, Reddy L N; Yang, Xufei; Watson, John G

    2018-05-01

    A thermal/optical carbon analyzer (TOA), normally used for quantification of organic carbon (OC) and elemental carbon (EC) in PM 2.5 (fine particulate matter) speciation networks, was adapted to direct thermally evolved gases to an electron impact quadrupole mass spectrometer (QMS), creating a TOA-QMS. This approach produces spectra similar to those obtained by the Aerodyne aerosol mass spectrometer (AMS), but the ratios of the mass to charge (m/z) signals differ and must be remeasured using laboratory-generated standards. Linear relationships are found between TOA-QMS signals and ammonium (NH 4 + ), nitrate (NO 3 - ), and sulfate (SO 4 2- ) standards. For ambient samples, however, positive deviations are found for SO 4 2- , compensated by negative deviations for NO 3 - , at higher concentrations. This indicates the utility of mixed-compound standards for calibration or separate calibration curves for low and high ion concentrations. The sum of the QMS signals across all m/z after removal of the NH 4 + , NO 3 - , and SO 4 2- signals was highly correlated with the carbon content of oxalic acid (C₂H₂O₄) standards. For ambient samples, the OC derived from the TOA-QMS method was the same as the OC derived from the standard IMPROVE_A TOA method. This method has the potential to reduce complexity and costs for speciation networks, especially for highly polluted urban areas such as those in Asia and Africa. Ammonium, nitrate, and sulfate can be quantified by the same thermal evolution analysis applied to organic and elemental carbon. This holds the potential to replace multiple parallel filter samples and separate laboratory analyses with a single filter and a single analysis to account for a large portion of the PM 2.5 mass concentration.

  7. Ultrasonography of hydronephrosis and renal masses

    International Nuclear Information System (INIS)

    Lee, Kyung Weon; Kim, Chong Gun; Kim, Yeon Jin; Rhee, Byung Chull

    1984-01-01

    We have analyzed ultrasonographic findings of 55 cases of hydronephrosis and 34 cases of renal masses. The results are as follows: 1. 55 cases of hydronephrosis revealed renal enlargement in 55 cases, separation of central echo complex in 27 cases, multiple anechoic areas radiating from the center in 25 cases and dilated renal pelvis in 24 cases. 2. Among the masses in 34 cases, simple renal cyst were 15 cases, polycystic kidney in 8 cases, hypernephroma in 8 cases, Wilm's tumor in 2 cases and agiomyolipoma in 1 case. 3. Simple renal cyst revealed single in 14 cases (93%) and well defined anechoic mass with posterior enhancement in all cases. 4. Polycystic kidney revealed bilateral irregular shaped renal enlargement and multiple anechoic cysts throughout the kidney. 2 cases (25%) involved liver. 5. 6 cases (75%) of hypernephroma revealed ill defined moderately echogenic mass without posterior enhancement. 6. All cases of Wilm's tumor revealed well defined large mixed echogenic mass in right kidney. 7. Angiomyolipoma revealed bilateral dense echogenic mass with large hemorrhage cyst in right kidney. 8. The ultrasonography is useful noninvasive diagnostic modality of evaluation of renal masses and hydronephrosis.

  8. STRAPS v1.0: evaluating a methodology for predicting electron impact ionisation mass spectra for the aerosol mass spectrometer

    Directory of Open Access Journals (Sweden)

    D. O. Topping

    2017-06-01

    Full Text Available Our ability to model the chemical and thermodynamic processes that lead to secondary organic aerosol (SOA formation is thought to be hampered by the complexity of the system. While there are fundamental models now available that can simulate the tens of thousands of reactions thought to take place, validation against experiments is highly challenging. Techniques capable of identifying individual molecules such as chromatography are generally only capable of quantifying a subset of the material present, making it unsuitable for a carbon budget analysis. Integrative analytical methods such as the Aerosol Mass Spectrometer (AMS are capable of quantifying all mass, but because of their inability to isolate individual molecules, comparisons have been limited to simple data products such as total organic mass and the O : C ratio. More detailed comparisons could be made if more of the mass spectral information could be used, but because a discrete inversion of AMS data is not possible, this activity requires a system of predicting mass spectra based on molecular composition. In this proof-of-concept study, the ability to train supervised methods to predict electron impact ionisation (EI mass spectra for the AMS is evaluated. Supervised Training Regression for the Arbitrary Prediction of Spectra (STRAPS is not built from first principles. A methodology is constructed whereby the presence of specific mass-to-charge ratio (m∕z channels is fitted as a function of molecular structure before the relative peak height for each channel is similarly fitted using a range of regression methods. The widely used AMS mass spectral database is used as a basis for this, using unit mass resolution spectra of laboratory standards. Key to the fitting process is choice of structural information, or molecular fingerprint. Our approach relies on using supervised methods to automatically optimise the relationship between spectral characteristics and these molecular

  9. STRAPS v1.0: evaluating a methodology for predicting electron impact ionisation mass spectra for the aerosol mass spectrometer

    Science.gov (United States)

    Topping, David O.; Allan, James; Rami Alfarra, M.; Aumont, Bernard

    2017-06-01

    Our ability to model the chemical and thermodynamic processes that lead to secondary organic aerosol (SOA) formation is thought to be hampered by the complexity of the system. While there are fundamental models now available that can simulate the tens of thousands of reactions thought to take place, validation against experiments is highly challenging. Techniques capable of identifying individual molecules such as chromatography are generally only capable of quantifying a subset of the material present, making it unsuitable for a carbon budget analysis. Integrative analytical methods such as the Aerosol Mass Spectrometer (AMS) are capable of quantifying all mass, but because of their inability to isolate individual molecules, comparisons have been limited to simple data products such as total organic mass and the O : C ratio. More detailed comparisons could be made if more of the mass spectral information could be used, but because a discrete inversion of AMS data is not possible, this activity requires a system of predicting mass spectra based on molecular composition. In this proof-of-concept study, the ability to train supervised methods to predict electron impact ionisation (EI) mass spectra for the AMS is evaluated. Supervised Training Regression for the Arbitrary Prediction of Spectra (STRAPS) is not built from first principles. A methodology is constructed whereby the presence of specific mass-to-charge ratio (m/z) channels is fitted as a function of molecular structure before the relative peak height for each channel is similarly fitted using a range of regression methods. The widely used AMS mass spectral database is used as a basis for this, using unit mass resolution spectra of laboratory standards. Key to the fitting process is choice of structural information, or molecular fingerprint. Our approach relies on using supervised methods to automatically optimise the relationship between spectral characteristics and these molecular fingerprints. Therefore

  10. Evaluation of mass absorption in LiBr flat-fan sheets

    International Nuclear Information System (INIS)

    Palacios, E.; Izquierdo, M.; Marcos, J.D.; Lizarte, R.

    2009-01-01

    Experiments were conducted to determine the absorption rates of refrigerant vapour in an aqueous lithium bromide flat-fan sheet for use in absorption air-conditioning systems. The solution flow rates tested ranged from 0.023 to 0.054 kg/s (84-194 kg/h), with pressure losses in the injection nozzle of from 40 to 250 kPa. The effect of the mass flow rate on both solution residence time and the sheet deformation rate was also analyzed in absorption chambers of a pre-defined length, along with the effect of the sub-cooling temperature on the amount of vapour absorbed. The downstream evolution of approach to equilibrium factor F was quantified. The mass transfer coefficient values were found to be over 3 x 10 -4 m/s. In absorption chambers 100 mm long, over 0.8 g/s l of vapour were absorbed per chamber absorption volume. Moreover, about 600 g of vapour were absorbed per kJ of solution flow work. Flat-fan sheet configurations were found to perform better than falling film and spray absorbers.

  11. Evaluation of the three-nucleon analyzing power puzzle

    International Nuclear Information System (INIS)

    Tornow, W.; Witala, H.

    1998-01-01

    The current status of the three-nucleon analyzing power puzzle is reviewed. Applying tight constraints on the allowed deviations between calculated predictions and accepted values for relevant nucleon-nucleon observables reveals that energy independent correction factors applied to the 3 P j nucleon-nucleon interactions can not solve the puzzle. Furthermore, using the same constraints, charge-independence breaking in the 3 P j nucleon-nucleon interactions can be ruled out as a possible tool to improve the agreement between three-nucleon calculations and data. The study of the energy dependence of the three-nucleon analyzing power puzzle gives clear evidence that the 3 P j nucleon-nucleon interaction obtained from phase-shift analyses and used in potential models are correct above about 25 MeV, i.e., the 3 P j nucleon-nucleon interactions have to be modified only at lower energies in order to solve the three-nucleon analyzing power puzzle, unless new three-nucleon forces can be found that account for the three-nucleon analyzing power puzzle without destroying the beautiful agreement between rigorous three-nucleon calculations and a large body of accurate three-nucleon data. (orig.)

  12. Evaluation of the three-nucleon analyzing power puzzle

    Energy Technology Data Exchange (ETDEWEB)

    Tornow, W. [Duke Univ., Durham, NC (United States). Dept. of Physics]|[Triangle Univ. Nuclear Lab., Durham, NC (United States); Witala, H. [Uniwersytet Jagiellonski, Cracow (Poland). Inst. Fizyki

    1998-07-20

    The current status of the three-nucleon analyzing power puzzle is reviewed. Applying tight constraints on the allowed deviations between calculated predictions and accepted values for relevant nucleon-nucleon observables reveals that energy independent correction factors applied to the {sup 3}P{sub j} nucleon-nucleon interactions can not solve the puzzle. Furthermore, using the same constraints, charge-independence breaking in the {sup 3}P{sub j} nucleon-nucleon interactions can be ruled out as a possible tool to improve the agreement between three-nucleon calculations and data. The study of the energy dependence of the three-nucleon analyzing power puzzle gives clear evidence that the {sup 3}P{sub j} nucleon-nucleon interaction obtained from phase-shift analyses and used in potential models are correct above about 25 MeV, i.e., the {sup 3}P{sub j} nucleon-nucleon interactions have to be modified only at lower energies in order to solve the three-nucleon analyzing power puzzle, unless new three-nucleon forces can be found that account for the three-nucleon analyzing power puzzle without destroying the beautiful agreement between rigorous three-nucleon calculations and a large body of accurate three-nucleon data. (orig.) 18 refs.

  13. Evaluation of body mass index and plasma lipid profile in dogs ...

    African Journals Online (AJOL)

    This study evaluated the body mass index (BMI), plasma lipid profile and gait assessment score (GAS) in dogs. Body weights (BW), height (H) at shoulder and waist circumference (WC) were obtained from fifty client-owned dogs of both sexes to determine the BMI. In addition, body condition score (BCS) and GAS were ...

  14. Evaluation of body mass index and plasma lipid profile in Boerboel ...

    African Journals Online (AJOL)

    This study evaluated the body mass index (BMI) and plasma lipid profile in Boerboel dogs. Body weights (BW), height (H) at shoulder and waist circumference (WC) were obtained from fifty-three Boerboels to determine the BMI while, body condition score (BCS) was determined subjectively. Also 5mls of blood was obtained ...

  15. An evaluation of the role of the mass media in conflict management ...

    African Journals Online (AJOL)

    An evaluation of the role of the mass media in conflict management: The Niger ... ups and downs to the public within the ambit of social responsibility theory of the ... Thus, blowing mere misunderstanding and misconception of issues from the ...

  16. Dust coma of Halley comet: measurements with the dust counter and mass analyzer (DUSMA)

    International Nuclear Information System (INIS)

    Simpson, J.A.; Sagdeev, R.Z.; Tuzzolino, A.J.; AN SSSR, Moscow. Inst. Kosmicheskikh Issledovanij)

    1986-01-01

    The paper represents a preliminary report on measurements of spatial and temporal distribution of mass and flows of dust particles coming from comet nucleus performed by means of devices constructed on the new principle of detecting comet dust specks. The device has a high time resolution (∼ 4 μs) in the wide range of mass and dust flows. On the base of a preliminary analysis the following conclusions are drawn: dust coma in quiet state (''Vega-2'') as well as at the presence of considerable emissions (''Vega-1'') manifests the presence of important short-term out-bursts having by time a quasi-periodic structure. Integral mass spectra show flows intensity growth with the decrease of measured mass (which contradicts some theoretical models). Flow levels lie approximately in the region previously determined by ground observations. The coma is extremely dynamic both in space and in time which proves the complex structure of regions of dust emission from the nucleus

  17. Evaluation of methods for MR imaging of human right ventricular heart volumes and mass

    International Nuclear Information System (INIS)

    Jauhiainen, T.; Jaervinen, V.M.; Hekali, P.E.

    2002-01-01

    Purpose: To assess the utility of two different imaging directions in the evaluation of human right ventricular (RV) heart volumes and mass with MR imaging; to compare breath-hold vs. non-breath-hold imaging in volume analysis; and to compare turbo inversion recovery imaging (TIR) with gradient echo imaging in RV mass measurement. Material and Methods: We examined 12 healthy volunteers (age 27-59 years). Breath-hold gradient echo MR imaging was performed in two imaging planes: 1) perpendicular to the RV inflow tract (RVIT view), and 2) in the transaxial view (TA view). The imaging was repeated in the TA view while the subjects were breathing freely. To analyze RV mass using TIR images, the RV was again imaged at end-diastole using the two views. The RV end-diastolic cavity (RVEDV) and muscle volume as well as end-systolic cavity volume (RVESV) were determined with the method of discs. All measurements were done blindly twice to assess repeatability of image analysis. To assess reproducibility of the measurements, 6 of the subjects were imaged twice at an interval of 5-9 weeks. Results: RVEDV averaged 133.2 ml, RVESV 61.5 ml and the RVmass 46.2 g in the RVIT view and 119.9 ml, 56.9 ml and 38.3 g in the TA view, respectively. The volumes obtained with breath-holding were slightly but not significantly smaller than the volumes obtained during normal breathing. There were no marked differences in the RV muscle mass obtained with gradient echo imaging compared to TIR imaging in either views. Repeatability of volume analysis was better in TA than RVIT view: the mean differences were 0.7±4.0 ml and 5.4±14.0 ml in end-diastole and 1.6±3.1 ml and 1.5±13.9 ml in end-systole, respectively. Repeatability of mass analysis was good in both TIR and cine images in the RVIT view but slightly better in TIR images: 0.5±2.4 g compared to 0.8±2.9 g in cine images. Reproducibility of imaging was good, mean differences for RVEDV and RVESV were 1.0±4.8 ml and 0.8±2.8 ml

  18. Evaluation of a High Resolving Power Time-of-Flight Mass Spectrometer for Drug Analysis in Terms of Resolving Power and Acquisition Rate

    Science.gov (United States)

    Pelander, Anna; Decker, Petra; Baessmann, Carsten; Ojanperä, Ilkka

    2011-02-01

    Liquid chromatography time-of-flight mass spectrometry (LC-TOFMS) is applied increasingly to various fields of small molecule analysis. The moderate resolving power (RP) of standard TOFMS instruments poses a risk of false negative results when complex biological matrices are to be analyzed. In this study, the performance of a high resolving power TOFMS instrument (maXis by Bruker Daltonik, Bremen, Germany) was evaluated for drug analysis. By flow injection analysis of critical drug mixtures, including a total of 17 compounds with nominal masses of 212-415 Da and with mass differences of 8.8-23.5 mDa, RP varied from 34,400 to 51,900 (FWHM). The effect of acquisition rate on RP, mass accuracy, and isotopic pattern fit was studied by applying 1, 2, 5, 10, and 20 Hz acquisition rates in a 16 min gradient elution LC separation. All three variables were independent of the acquisition rate, with an average mass accuracy and isotopic pattern fit factor (mSigma) of 0.33 ppm and 5.9, respectively. The average relative standard deviation of RP was 1.8%, showing high repeatability. The performance was tested further with authentic urine extracts containing a co-eluting compound pair with a nominal mass of 296 Da and an 11.2 mDa mass difference. The authentic sample components were readily resolved and correctly identified by the automated data analysis. The average RP, mass accuracy, and isotopic pattern fit were 36,600, 0.9 ppm, and 7.3 mSigma, respectively.

  19. On-Demand Urine Analyzer

    Science.gov (United States)

    Farquharson, Stuart; Inscore, Frank; Shende, Chetan

    2010-01-01

    A lab-on-a-chip was developed that is capable of extracting biochemical indicators from urine samples and generating their surface-enhanced Raman spectra (SERS) so that the indicators can be quantified and identified. The development was motivated by the need to monitor and assess the effects of extended weightlessness, which include space motion sickness and loss of bone and muscle mass. The results may lead to developments of effective exercise programs and drug regimes that would maintain astronaut health. The analyzer containing the lab-on-a- chip includes materials to extract 3- methylhistidine (a muscle-loss indicator) and Risedronate (a bone-loss indicator) from the urine sample and detect them at the required concentrations using a Raman analyzer. The lab-on- a-chip has both an extractive material and a SERS-active material. The analyzer could be used to monitor the onset of diseases, such as osteoporosis.

  20. Higgs-boson masses and mixing matrices in the NMSSM

    DEFF Research Database (Denmark)

    Drechsel, P.; Gröber, R.; Heinemeyer, S.

    2017-01-01

    We analyze the Higgs-boson masses and mixing matrices in the NMSSM based on an on-shell (OS) renormalization of the gauge-boson and Higgs-boson masses and the parameters of the top/scalar top sector. We compare the implementation of the OS calculations in the codes NMSSMCALC and NMSSM-FeynHiggs up...... to O(αtαs). We identify the sources of discrepancies at the one- and at the two-loop level. Finally we compare the OS and DR ¯ evaluation as implemented in NMSSMCALC. The results are important ingredients for an estimate of the theoretical precision of Higgs-boson mass calculations in the NMSSM....

  1. The evaluation of properties of coal mass from the viewpoint of environment

    Energy Technology Data Exchange (ETDEWEB)

    Foniok, R.; Lukes, M. [Research Mining Inst., Ostrava-Radvanice (Czechoslovakia)

    1995-12-01

    This paper deals with the evaluation of several various coal kinds from the Czech coalfields from the viewpoint of the development of thermal processes in coal mass due to their tendency towards self- ignition during storing. In such a case that no self-ignition during storing occurs, gaseous products are liberated into air, the quantity and composition of which depend upon fuel type and its temperature as well. From the environmental viewpoint, substances washed from stored coal are of a certain interest, too. In accordance with this fact, the importance of measures against self-heating of stored coal mass and the importance of a detailed observation of coal quality are concluded. The tables, which compare various coal kinds from the viewpoint of their behavior at self-ignition processes, are the integral part of this presented paper. Our greatest attention is paid to both the quantity and composition of gases being liberated in dependence upon the temperature of coal mass, and at its crushing with regard to selected methods and means of milling circuits before and explosion. Oxygen sorption by means of coal mass is also observed, being of a great importance for self-inertization of closed tanks. All the above-mentioned processes are demonstrated in form of graphic plots. Qualitative signs of coal mass are the basic means for its assessment from the viewpoint of emissions at burning/combustion, and the evaluation of explosive properties. A great attention is paid to explosion-proof means being produced in the Czech Republic. These means can be used for protection of milling circuits of power plants and heating plants or for safety systems of combustion chamber by means of insulation to secondary air main. Explosion-proof quci-acting valves, a special type of safety membrane and device for explosion suppression nip in the bud do represent the latest explosion-proof means.

  2. Weapons of Mass Destruction Technology Evaluation and Training Range

    Energy Technology Data Exchange (ETDEWEB)

    Kevin Larry Young

    2009-05-01

    The Idaho National Laboratory (INL) has a long history for providing technology evaluation and training for military and other federal level Weapons of Mass Destruction (WMD) response agencies. Currently there are many federal organizations and commercial companies developing technologies related to detecting, assessing, mitigating and protecting against hazards associated with a WMD event. Unfortunately, very few locations exist within the United States where WMD response technologies are realistically field tested and evaluated using real chemical, biological, radiological, nuclear and explosive materials. This is particularly true with biological and radiological hazards. Related to this lack of adequate WMD, multi-hazard technology testing capability is the shortage of locations where WMD response teams can train using actual chemical, biological, and radiological material or highly realistic simulates. In response to these technology evaluation and training needs, the INL has assembled a consortium of subject matter experts from existing programs and identified dedicated resources for the purpose of establishing an all-hazards, WMD technology evaluation and training range. The author describes the challenges associated with creating the all-hazards WMD technology evaluation and training range and lists the technical, logistical and financial benefits of an all-hazards technology evaluation and training range. Current resources and capabilities for conducting all-hazard technology evaluation and training at the INL are identified. Existing technology evaluation and training programs at the INL related to radiological, biological and chemical hazards are highlighted, including successes and lessons learned. Finally, remaining gaps in WMD technology evaluation and training capabilities are identified along with recommendations for closing those gaps.

  3. Clinical application of S-Detect to breast masses on ultrasonography: A study evaluating the diagnostic performance and agreement with a dedicated breast radiologist

    International Nuclear Information System (INIS)

    Kim, Ki Wook; Kim, Eun Kyung; Yoon, Jung Hyun; Song, Mi Kyung

    2017-01-01

    The purpose of this study was to evaluate the diagnostic performance of S-Detect when applied to breast ultrasonography (US), and the agreement with an experienced radiologist specializing in breast imaging. From June to August 2015, 192 breast masses in 175 women were included. US features of the breast masses were retrospectively analyzed by a radiologist who specializes in breast imaging and S-Detect, according to the fourth edition of the American College of Radiology Breast Imaging Reporting and Data System lexicon and final assessment categories. Final assessments from S-Detect were in dichotomized form: possibly benign and possibly malignant. Kappa statistics were used to analyze the agreement between the radiologist and S-Detect. Diagnostic performance of the radiologist and S-Detect was calculated, including sensitivity, specificity, positive predictive value (PPV), negative predictive value, accuracy, and area under the receiving operator characteristics curve. Of the 192 breast masses, 72 (37.5%) were malignant, and 120 (62.5%) were benign. Benign masses among category 4a had higher rates of possibly benign assessment on S-Detect for the radiologist, 63.5% to 36.5%, respectively (P=0.797). When the cutoff was set at category 4a, the specificity, PPV, and accuracy was significantly higher in S-Detect compared to the radiologist (all P<0.05), with a higher area under the receiver operator characteristics curve of 0.725 compared to 0.653 (P=0.038). Moderate agreement (k=0.58) was seen in the final assessment between the radiologist and S-Detect. S-Detect may be used as an additional diagnostic tool to improve the specificity of breast US in clinical practice, and guide in decision making for breast masses detected on US

  4. Evaluation of hybrids algorithms for mass detection in digitalized mammograms

    International Nuclear Information System (INIS)

    Cordero, Jose; Garzon Reyes, Johnson

    2011-01-01

    The breast cancer remains being a significant public health problem, the early detection of the lesions can increase the success possibilities of the medical treatments. The mammography is an image modality effective to early diagnosis of abnormalities, where the medical image is obtained of the mammary gland with X-rays of low radiation, this allows detect a tumor or circumscribed mass between two to three years before that it was clinically palpable, and is the only method that until now achieved reducing the mortality by breast cancer. In this paper three hybrids algorithms for circumscribed mass detection on digitalized mammograms are evaluated. In the first stage correspond to a review of the enhancement and segmentation techniques used in the processing of the mammographic images. After a shape filtering was applied to the resulting regions. By mean of a Bayesian filter the survivors regions were processed, where the characteristics vector for the classifier was constructed with few measurements. Later, the implemented algorithms were evaluated by ROC curves, where 40 images were taken for the test, 20 normal images and 20 images with circumscribed lesions. Finally, the advantages and disadvantages in the correct detection of a lesion of every algorithm are discussed.

  5. Detailed evaluation of the natural circulation mass flow rate of water propelled by using an air injection

    International Nuclear Information System (INIS)

    Park, Rae-Joon; Ha, Kwang-Soon; Kim, Jae-Cheol; Hong, Seong-Wan; Kim, Sang-Baik

    2008-01-01

    One-dimensional (1D) air-water two-phase natural circulation flow in the thermohydraulic evaluation of reactor cooling mechanism by external self-induced flow - one-dimensional' (THERMES-1D) experiment has been verified and evaluated by using the RELAP5/MOD3 computer code. Experimental results on the 1D natural circulation mass flow rate of water propelled by using an air injection have been evaluated in detail. The RELAP5 results have shown that an increase in the air injection rate to 50% of the total heat flux leads to an increase in the water circulation mass flow rate. However, an increase in the air injection rate from 50 to 100% does not affect the water circulation mass flow rate, because of the inlet area condition. As the height increases in the air injection part, the void fraction increases. However, the void fraction in the upper part of the air injector maintains a constant value. An increase in the air injection mass flow rate leads to an increase in the local void fraction, but it has no influence on the local pressure. An increase in the coolant inlet area leads to an increase in the water circulation mass flow rate. However, the water outlet area does not have an influence on the water circulation mass flow rate. As the coolant outlet moves to a lower position, the water circulation mass flow rate decreases. (author)

  6. Fourier Transform Mass Spectrometry

    Science.gov (United States)

    Scigelova, Michaela; Hornshaw, Martin; Giannakopulos, Anastassios; Makarov, Alexander

    2011-01-01

    This article provides an introduction to Fourier transform-based mass spectrometry. The key performance characteristics of Fourier transform-based mass spectrometry, mass accuracy and resolution, are presented in the view of how they impact the interpretation of measurements in proteomic applications. The theory and principles of operation of two types of mass analyzer, Fourier transform ion cyclotron resonance and Orbitrap, are described. Major benefits as well as limitations of Fourier transform-based mass spectrometry technology are discussed in the context of practical sample analysis, and illustrated with examples included as figures in this text and in the accompanying slide set. Comparisons highlighting the performance differences between the two mass analyzers are made where deemed useful in assisting the user with choosing the most appropriate technology for an application. Recent developments of these high-performing mass spectrometers are mentioned to provide a future outlook. PMID:21742802

  7. MALDI Mass Spectrometry Imaging for Evaluation of Therapeutics in Colorectal Tumor Organoids

    Science.gov (United States)

    Liu, Xin; Flinders, Colin; Mumenthaler, Shannon M.; Hummon, Amanda B.

    2018-03-01

    Patient-derived colorectal tumor organoids (CTOs) closely recapitulate the complex morphological, phenotypic, and genetic features observed in in vivo tumors. Therefore, evaluation of drug distribution and metabolism in this model system can provide valuable information to predict the clinical outcome of a therapeutic response in individual patients. In this report, we applied matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) to examine the spatial distribution of the drug irinotecan and its metabolites in CTOs from two patients. Irinotecan is a prodrug and is often prescribed as part of therapeutic regimes for patients with advanced colorectal cancer. Irinotecan shows a time-dependent and concentration-dependent permeability and metabolism in the CTOs. More interestingly, the active metabolite SN-38 does not co-localize well with the parent drug irinotecan and the inactive metabolite SN-38G. The phenotypic effect of irinotecan metabolism was also confirmed by a viability study showing significantly reduced proliferation in the drug treated CTOs. MALDI-MSI can be used to investigate various pharmaceutical compounds in CTOs derived from different patients. By analyzing multiple CTOs from a patient, this method could be used to predict patient-specific drug responses and help to improve personalized dosing regimens. [Figure not available: see fulltext.

  8. Evaluation of the U-Pu residual mass from spent fuel assemblies with passive and active neutronic methods

    International Nuclear Information System (INIS)

    Bignan, G.; Martin-Deidier, L.

    1991-01-01

    The interpretation of passive and active neutronic measurements to evaluate the U-Pu residual mass in spent fuel assemblies is presented as follows: passive neutron measurements are well correlated to the plutonium mass, active neutron measurements give information linked to the fissile mass content of the assembly ( 235 U + 239 Pu + 241 Pu) and, using the passive neutron measurement, lead to the 235 U mass content of the assemblies

  9. Use Of Stream Analyzer For Solubility Predictions Of Selected Hanford Tank Waste

    International Nuclear Information System (INIS)

    Pierson, Kayla; Belsher, Jeremy; Ho, Quynh-dao

    2012-01-01

    The Hanford Tank Waste Operations Simulator (HTWOS) models the mission to manage, retrieve, treat and vitrify Hanford waste for long-term storage and disposal. HTWOS is a dynamic, flowsheet, mass balance model of waste retrieval and treatment activities. It is used to evaluate the impact of changes on long-term mission planning. The project is to create and evaluate the integrated solubility model (ISM). The ISM is a first step in improving the chemistry basis in HTWOS. On principal the ISM is better than the current HTWOS solubility. ISM solids predictions match the experimental data well, with a few exceptions. ISM predictions are consistent with Stream Analyzer predictions except for chromium. HTWOS is producing more realistic results with the ISM

  10. Mass Spectrometric Method for Analyzing Metabolites in Yeast with Single Cell Sensitivity

    NARCIS (Netherlands)

    Amantonico, Andrea; Oh, Joo Yeon; Sobek, Jens; Heinemann, Matthias; Zenobi, Renato

    2008-01-01

    Getting a look-in: An optimized MALDI-MS procedure has been developed to detect endogenous primary metabolites directly in the cell extract. A detection limit corresponding to metabolites from less than a single cell has been attained, opening the door to single-cell metabolomics by mass

  11. A Low Cost Shading Analyzer and Site Evaluator Design to Determine Solar Power System Installation Area

    Directory of Open Access Journals (Sweden)

    Selami Kesler

    2015-01-01

    Full Text Available Shading analyzer systems are necessary for selecting the most suitable installation site to sustain enough solar power. Afterwards, changes in solar data throughout the year must be evaluated along with the identification of obstructions surrounding the installation site in order to analyze shading effects on productivity of the solar power system. In this study, the shading analysis tools are introduced briefly, and a new and different device is developed and explained to analyze shading effect of the environmental obstruction on the site on which the solar power system will be established. Thus, exposure duration of the PV panels to the sunlight can be measured effectively. The device is explained with an application on the installation area selected as a pilot site, Denizli, in Turkey.

  12. Quality requirements for veterinary hematology analyzers in small animals-a survey about veterinary experts' requirements and objective evaluation of analyzer performance based on a meta-analysis of method validation studies: bench top hematology analyzer.

    Science.gov (United States)

    Cook, Andrea M; Moritz, Andreas; Freeman, Kathleen P; Bauer, Natali

    2016-09-01

    Scarce information exists about quality requirements and objective evaluation of performance of large veterinary bench top hematology analyzers. The study was aimed at comparing the observed total error (TEobs ) derived from meta-analysis of published method validation data to the total allowable error (TEa ) for veterinary hematology variables in small animals based on experts' opinions. Ideally, TEobs should be hematology analyzers (ADVIA 2120; Sysmex XT2000iV, and CellDyn 3500) was calculated based on method validation studies published between 2005 and 2013 (n = 4). The percent TEobs = 2 * CV (%) + bias (%). The CV was derived from published studies except for the ADVIA 2120 (internal data), and bias was estimated from the regression equation. A total of 41 veterinary experts (19 diplomates, 8 residents, 10 postgraduate students, 4 anonymous specialists) responded. The proposed range of TEa was wide, but generally ≤ 20%. The TEobs was < TEa for all variables and analyzers except for canine and feline HGB (high bias, low CV) and platelet counts (high bias, high CV). Overall, veterinary bench top analyzers fulfilled experts' requirements except for HGB due to method-related bias, and platelet counts due to known preanalytic/analytic issues. © 2016 American Society for Veterinary Clinical Pathology.

  13. Statistical program for the data evaluation of a thermal ionization mass spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    van Raaphorst, J. G.

    1978-12-15

    A computer program has been written to statistically analyze mass spectrometer measurements. The program tests whether the difference between signal and background intensities is statistically significant, corrects for signal drift in the measured values, and calculates ratios against the main isotope from the corrected intensities. Repeated ratio value measurements are screened for outliers using the Dixon statistical test. Means of ratios and the coefficient of variation are calculated and reported. The computer program is written in Basic and is available for anyone who is interested.

  14. Hybrid recoil mass analyzer at IUAC – First results using gas-filled ...

    Indian Academy of Sciences (India)

    kinematics (to access heavy nuclei around 200 amu mass and beyond) and both ... totype each of RFQ and DTL are undergoing detailed tests for field ... magnet MD1 in gas-filled mode and is especially attractive in reactions induced by ... calculated using GIOS [11] ion-optical program to get the maximum count rate on.

  15. Total homocysteine is positively correlated with body mass index, waist-to-hip ratio, and fat mass among overweight reproductive women: A cross-sectional study.

    Science.gov (United States)

    Al-Bayyari, Nahla; Hamadneh, Jehan; Hailat, Rae'd; Hamadneh, Shereen

    2017-12-01

    Conflicting associations between total homocysteine (tHcy), body mass index (BMI) lean body mass, and fat mass in the general population have been reported. We investigated the hypothesis that elevated tHcy levels are associated with increased BMI, waist-to-hip ratio (WHR), and body fat mass percent. In Jordan, obesity and overweight are prevalent among reproductive women and hyperhomocysteinemia, along with obesity and overweight, are independent risk factors for cardiovascular diseases. The participants used in this cross-sectional study were 325 overweight Jordanian women aged between 18 and 49 years old. The main outcome measures were tHcy, BMI, WHR, fat mass, fat-free mass, and total body water. Serum tHcy was analyzed using a liquid chromatography tandem mass spectrophotometry (LC-MS/MS) complete kit. The body compositions were measured using a bioelectrical impedance analyzer. Study participants were stratified according to their tHcy level into two groups, ≤10 μmol/L and >10 μmol/L, and the difference between mean values of body compositions was evaluated. The tHcy was significantly and negatively correlated with age, fat-free mass, and total body water, and significantly and positively correlated with BMI, hip circumference, WHR, fat mass, and dry lean weight. The chi-square and the independent sample t-tests showed statistically significant (P ≤ .05) differences between tHcy and BMI, WHR, fat and fat-free mass, and total body water percentages. In conclusion, BMI, WHR and body fat mass were found to be associated with elevated tHcy levels among overweight reproductive women, and they might be used as independent predictors of the tHcy level. Copyright © 2017 Elsevier Inc. All rights reserved.

  16. First on-line applications of a multi-reflection time-of-flight mass separator at ISOLTRAP and the mass measurement of 82Zn

    International Nuclear Information System (INIS)

    Wolf, Robert

    2013-01-01

    ) mass models, HFB-19 to HFB-21, of the BRUSLIB collaboration. The mass of the nuclide is of high interest for the compositions and depth profile of the outer crust of neutron stars. In the classical model of the outer crust of a cold, non-accrediting and non-rotating neutron star, the sequence of nuclides found within this parts is determined mainly by the binding energy of exotic nuclides. The crustal compositions determined with the three HFB mass models differed with respect to the appearance of a layer of 82 Zn, originating from different mass extrapolations of this mass. With the new experimental data, the extrapolations could be evaluated. It was found that the HFB-21 mass value differs less from the experimental data than the ones from HFB-19 and 20. Therefore, in the classical model, 82 Zn does not appear anymore in the outer crust. Due to its high resolution and very fast measurement time, the MR-ToF mass analyzer will be an important instruments for future activities at ISOLTRAP, at the ISOLDE facility in general, and at other radioactive ion-beam facilities.

  17. A new qualitative pattern classification of shear wave elastograghy for solid breast mass evaluation.

    Science.gov (United States)

    Cong, Rui; Li, Jing; Guo, Song

    2017-02-01

    To examine the efficacy of qualitative shear wave elastography (SWE) in the classification and evaluation of solid breast masses, and to compare this method with conventional ultrasonograghy (US), quantitative SWE parameters and qualitative SWE classification proposed before. From April 2015 to March 2016, 314 consecutive females with 325 breast masses who decided to undergo core needle biopsy and/or surgical biopsy were enrolled. Conventional US and SWE were previously performed in all enrolled subjects. Each mass was classified by two different qualitative classifications. One was established in our study, herein named the Qual1. Qual1 could classify the SWE images into five color patterns by the visual evaluations: Color pattern 1 (homogeneous pattern); Color pattern 2 (comparative homogeneous pattern); Color pattern 3 (irregularly heterogeneous pattern); Color pattern 4 (intralesional echo pattern); and Color pattern 5 (the stiff rim sign pattern). The second qualitative classification was named Qual2 here, and included a four-color overlay pattern classification (Tozaki and Fukuma, Acta Radiologica, 2011). The Breast Imaging Reporting and Data System (BI-RADS) assessment and quantitative SWE parameters were recorded. Diagnostic performances of conventional US, SWE parameters, and combinations of US and SWE parameters were compared. With pathological results as the gold standard, of the 325 examined breast masses, 139 (42.77%) samples were malignant and 186 (57.23%) were benign. The Qual1 showed a higher Az value than the Qual2 and quantitative SWE parameters (all Pbreast mass diagnoses. Copyright © 2016. Published by Elsevier B.V.

  18. Space radiation evaluation of 16Mbit DRAMs for mass memory applications

    International Nuclear Information System (INIS)

    Calvel, P.; Lamothe, P.; Barillot, C.; Ecoffet, R.; Duzellier, S.; Stassinopoulos, E.G.

    1994-01-01

    In the frame of Mass Memory Applications for space missions, 16 Mbit DRAM from IBM and TEXAS INSTRUMENTS have been evaluated to space radiation, by the CECIL heavy ions testing coordination group. This paper presents heavy ions, protons and total dose data results for 16 Mbit DRAMs from IBM and TEXAS INSTRUMENTS, including a 'built-in ECC' DRAM. Single Event Phenomena rate are calculated for low earth orbits

  19. Very low mass stars

    International Nuclear Information System (INIS)

    Liebert, J.; Probst, R.G.

    1987-01-01

    This paper discusses several theoretical and observational topics involved in discovering and analyzing very low mass stellar objects below about 0.3 M circle, as well as their likely extension into the substellar range. The authors hereafter refer to these two classes of objects as VLM stars and brown dwarfs, respectively; collectively, they are called VLM objects. The authors outline recent theoretical work on low-mass stellar interiors and atmospheres, the determination of the hydrogen-burning mass limit, important dynamical evidence bearing on the expected numbers of such objects, and the expectations for such objects from star-formation theory. They focus on the properties of substellar objects near the stellar mass limit. Observational techniques used to discover and analyze VLM objects are summarized

  20. Usefulness of sonography in women less than 35 years old with palpable breast masses

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Ju; Chung, Hyun Ung; Park, Jin Gyoon; Seo, Jeong Jin; Kang, Heoung Keun; Kim, Jae Kyu; Chung, Hyon De [Chonnam National University College of Medicine, Gwangju (Korea, Republic of)

    1994-12-15

    To assess the usefulness of sonography in the evaluation of palpable mass in patients less than 35 years old,the breast sonograms and mammograms of 105 histopathologically proved cases were retrospectively reviewed. Breast parenchymal patterns on mammogram, sensitivity of sonography and mammography in the diagnosis of palpable breast masses, and sonographic findings of breast masses were analyzed. Grade IV breast parenchymal pattern was demonstrated in 44 of 76 mammogram (57.9%). The incidence of Grade IV pattern increased, as the patients' age became younger. The sensitivity of sonography (81.3%) was higher than that of mammography (45.3%) in the evaluation of the benign breast lesions. However, the sensitivity of both modalities were nearly equal (66.7% and 58.3% respectively) in the evaluation of the breast cancers. Sonographic findings of fibroadenoma included oval,well defined border, smooth contour, weak homogeneous internal echoes, posterior sonic enhancement, and bilateral shadows. On the other hand, breast cancer exhibited poorly defined border, irregular contour, and inhomogeneous hypoechoic mass with posterior sonic attenuation. In summary, sonography was useful in the evaluation of the palpable breast mass in women less than 35 years old. Choreoathetotic sonographic findings might help the differential diagnosis of breast masses

  1. Usefulness of sonography in women less than 35 years old with palpable breast masses

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyun Ju; Chung, Hyun Ung; Park, Jin Gyoon; Seo, Jeong Jin; Kang, Heoung Keun; Kim, Jae Kyu; Chung, Hyon De [Chonnam National University College of Medicine, Gwangju (Korea, Republic of)

    1994-12-15

    To assess the usefulness of sonography in the evaluation of palpable mass in patients less than 35 years old,the breast sonograms and mammograms of 105 histopathologically proved cases were retrospectively reviewed. Breast parenchymal patterns on mammogram, sensitivity of sonography and mammography in the diagnosis of palpable breast masses, and sonographic findings of breast masses were analyzed. Grade IV breast parenchymal pattern was demonstrated in 44 of 76 mammogram (57.9%). The incidence of Grade IV pattern increased, as the patients' age became younger. The sensitivity of sonography (81.3%) was higher than that of mammography (45.3%) in the evaluation of the benign breast lesions. However, the sensitivity of both modalities were nearly equal (66.7% and 58.3% respectively) in the evaluation of the breast cancers. Sonographic findings of fibroadenoma included oval,well defined border, smooth contour, weak homogeneous internal echoes, posterior sonic enhancement, and bilateral shadows. On the other hand, breast cancer exhibited poorly defined border, irregular contour, and inhomogeneous hypoechoic mass with posterior sonic attenuation. In summary, sonography was useful in the evaluation of the palpable breast mass in women less than 35 years old. Choreoathetotic sonographic findings might help the differential diagnosis of breast masses

  2. The transmission theory of electrostatic analyzer in six dimensional phase space and the concept design of a supersensitive mass spectrometer beam line for HI-13 tandem accelerator

    International Nuclear Information System (INIS)

    Guan Xialing; Cao Qingxi; Zhang Jie; Ye Jingping

    1986-01-01

    It follows from the motion equations of charged particle in curvilinear coordinates system that the transfer matrix of electrostatic analyzer was derived in six dimensional phase space. In accordance with these matrixes, the concept design of the supersensitive mass spectrometer beam line for HI-13 tandem accelerator was calculated

  3. Selected cis- and trans-3-fluorostyrene rotamers studied by two-color resonant two-photon mass-analyzed threshold ionization spectroscopy

    Science.gov (United States)

    Wu, Pei Ying; Tzeng, Wen Bih

    2015-10-01

    We applied two-color resonant two-photon ionization and mass-analyzed threshold ionization techniques to record the vibronic, photoionization efficiency, and cation spectra of the selected rotamers of 3-fluorostyrene. The adiabatic ionization energies of cis- and trans-3-fluorostyrene were determined to be 69 960 ± 5 and 69 856 ± 5 cm-1, respectively. Cation vibrations 10a, 15, 6b, and 12 of both rotamers have been found to have frequencies of 218, 404, 452, and 971 cm-1, respectively. This finding shows that the relative orientation of the vinyl group with respect to the F atom does not affect these vibrations of the 3-fluorostyrene cation. Our one-dimensional potential energy surface calculations support that the cis-trans isomerization of 3-fluorostyrene does not occur under the present experimental conditions.

  4. Development and evaluation of porcine cysticercosis QuickELISA in Triturus EIA analyzer.

    Science.gov (United States)

    Handali, Sukwan; Pattabhi, Sowmya; Lee, Yeuk-Mui; Silva-Ibanez, Maria; Kovalenko, Victor A; Levin, Andrew E; Gonzalez, Armando E; Roberts, Jacquelin M; Garcia, Hector H; Gilman, Robert H; Hancock, Kathy; Tsang, Victor C W

    2010-01-01

    We evaluated three diagnostic antigens (recombinant GP50, recombinant T24H, and synthetic Ts18var1) for cysticercosis and found that all three performed well in detecting cysticercosis in humans and pigs in several assay formats. These antigens were adapted to a new antibody detection format (QuickELISA). With one single incubation step which involves all reactants except the enzyme substrate, the QuickELISA is particularly suited for automation. We formatted the QuickELISA for the Triturus EIA analyzer for testing large numbers of samples. We found that in QuickELISA formats rGP50 and rT24H have better sensitivity and specificity than sTs18var1 for detecting porcine cysticercosis.

  5. Comparison of a burning mass ceramics coating in laboratory furnace and instrustrial furnace

    International Nuclear Information System (INIS)

    Soares, R.A.L.; Castro, J.R. de S.

    2012-01-01

    This work intends to analyze the differences obtained in the technological properties of a ceramic coating after firing in two distinct environments, laboratory furnace and industrial furnace. For this, was characterized a ceramic mass used in the production of porous coating. The analyzes were performed chemical, mineralogical and thermal mass in that. The specimens were obtained by compacting and burned in the maximum temperature of 1140 deg C in two furnaces, laboratory and industrial. The technological tests were performed linear shrinkage, water absorption, bulk density and mechanical strength. The microstructure was evaluated by ray-X diffraction and scanning electron microscopy. The results showed that both furnaces provided significant differences in analyzed specimens, such as increased strength and low water absorption in the fired samples in a laboratory furnace, for example. (author)

  6. PhosphoSiteAnalyzer

    DEFF Research Database (Denmark)

    Bennetzen, Martin V; Cox, Jürgen; Mann, Matthias

    2012-01-01

    an algorithm to retrieve kinase predictions from the public NetworKIN webpage in a semiautomated way and applies hereafter advanced statistics to facilitate a user-tailored in-depth analysis of the phosphoproteomic data sets. The interface of the software provides a high degree of analytical flexibility......Phosphoproteomic experiments are routinely conducted in laboratories worldwide, and because of the fast development of mass spectrometric techniques and efficient phosphopeptide enrichment methods, researchers frequently end up having lists with tens of thousands of phosphorylation sites...... and is designed to be intuitive for most users. PhosphoSiteAnalyzer is a freeware program available at http://phosphosite.sourceforge.net ....

  7. Reproducibility and diagnostic performance of shear wave elastography in evaluating breast solid mass.

    Science.gov (United States)

    Hong, Sun; Woo, Ok Hee; Shin, Hye Seon; Hwang, Soon-Young; Cho, Kyu Ran; Seo, Bo Kyoung

    Shear wave elastography (SWE) was performed independently by two radiologists in 264 solid breast masses. The images were reviewed for color overlay pattern (COP) classification by the two radiologists, double blinded to any information. The interobserver agreement of the COP was almost perfect (κ=0.908) and high in E max (ICC=0.89). The AUC value of the COP (0.954) was significantly higher than that of E max (0.915) (p=0.002) but not significantly different from that of E max combined with COP (0.957) (p=0.098). The SWE color overlay pattern and E max of breast masses were highly reproducible. The COP had better diagnostic ability than E max , suggesting that COP may be a more reliable parameter for solid breast mass evaluation. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Toxicity and Detoxification Effects of Herbal Caowu via Ultra Performance Liquid Chromatography/Mass Spectrometry Metabolomics Analyzed using Pattern Recognition Method

    Science.gov (United States)

    Yan, Yan; Zhang, Aihua; Dong, Hui; Yan, Guangli; Sun, Hui; Wu, Xiuhong; Han, Ying; Wang, Xijun

    2017-01-01

    Background: Caowu (Radix Aconiti kusnezoffii, CW), the root of Aconitum kusnezoffii Reichb., has widely used clinically in rheumatic arthritis, painful joints, and tumors for thousands of years. However, the toxicity of heart and central nervous system induced by CW still limited the application. Materials and Methods: Metabolomics was performed to identify the sensitive and reliable biomarkers and to characterize the phenotypically biochemical perturbations and potential mechanisms of CW-induced toxicity, and the detoxification by combinatorial intervention of CW with Gancao (Radix Glycyrrhizae) (CG), Baishao (Radix Paeoniae Alba) (CB), and Renshen (Radix Ginseng) (CR) was also analyzed by pattern recognition methods. Results: As a result, the metabolites were characterized and responsible for pentose and glucuronate interconversions, tryptophan metabolism, amino sugar and nucleotide sugar metabolism, taurine and hypotaurine metabolism, fructose and mannose metabolism, and starch and sucrose metabolism, six networks of which were the same to the metabolic pathways of Chuanwu (Radix Aconiti, CHW) group. The ascorbate and aldarate metabolism was also characterized by CW group. The urinary metabolomics also revealed CW-induced serious toxicity to heart and liver. Thirteen significant metabolites were identified and had validated as phenotypic toxicity biomarkers of CW, five biomarkers of which were commonly owned in Aconitum. The changes of toxicity metabolites obtained from combinatorial intervention of CG, CB, and CR also were analyzed to investigate the regulation degree of toxicity biomarkers adjusted by different combinatorial interventions at 6th month. Conclusion: Metabolomics analyses coupled with pattern recognition methods in the evaluation of drug toxicity and finding detoxification methods were highlighted in this work. SUMMARY Metabolomics was performed to characterize the biochemical potential mechanisms of Caowu toxicityThirteen significant metabolites

  9. Pericardial cyst with atypical location: densimetric evaluation of mediastinal masses by computerized tomography

    International Nuclear Information System (INIS)

    Franquet, T.; Jiminez, F.J.; Eguizabal, C.; Bescos, J.M.

    1991-01-01

    We present a case of pericardial cyst with atypical location. CT has been very usefull for densitometric evaluation of mediastinal masses. Using a combination of cross-section diagnostic methods and fine-needle aspiration (FNA), we can carry out accurate diagnoses of cystic lesions located in uncommom sites. (Author)

  10. 21 CFR 868.1720 - Oxygen gas analyzer.

    Science.gov (United States)

    2010-04-01

    ... gases by techniques such as mass spectrometry, polarography, thermal conductivity, or gas chromatography... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Oxygen gas analyzer. 868.1720 Section 868.1720 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED...

  11. Mass spectrometer and method with improved ion transmission

    International Nuclear Information System (INIS)

    Douglas, D.J.; French, J.B.

    1992-01-01

    This invention relates to a mass analyzer, and to a method of operating a mass analyzer, of the kind in which ions are transmitted through a first rod set for focussing and separation from an accompanying gas, before passing through a mass filter rod set which which permits transmission only of ions of a selected mass to charge ratio. (author). 19 figs

  12. Computed tomography of pediatric abdominal masses

    Energy Technology Data Exchange (ETDEWEB)

    Kook, Shin Ho; Ko, Eun Joo; Chung, Eun Chul; Suh, Jung Soo; Rhee, Chung Sik [College of Medicine, Ewha Womans University, Seoul (Korea, Republic of)

    1988-02-15

    Ultrasonography is a very useful diagnostic modality for evaluation of the pediatric abdominal masses, due to faster, cheaper, and no radiation hazard than CT. But CT has more advantages in assessing precise anatomic location, and extent of the pathologic process, and also has particular value in defining the size, relation of the mass to surrounding organs and detection of lymphadenopathy. We analyzed CT features of 35 cases of pathologically proven pediatric abdominal masses for recent 2 years at Ewha Woman's University Hospital. The results were as follows: 1.The most common originating site was kidney (20 cases, 57.1%); followed by gastrointestinal (5 cases, 14.3%), nonrenal retroperitoneal (4 cases, 11.4%), hepatobiliary (3 cases, 8.6%), and genital (3 cases, 8.6%) in order of frequency. 2.The most common mass was hydronephrosis (11 cases, 31.4%), Wilms' tumor (7 cases, 20.0%), neuroblastoma, choledochal cyst, periappendiceal abscess (3 cases, 8.6%, respectively), ovarian cyst (2 cases, 5.7%) were next in order of frequency. 3.Male to female ratio was 4:5 and choledochal cyst and ovarian cyst were found only in females. The most prevalent age group was 1-3 year old (12 cases, 34.3%). 4.With CT, the diagnosis of hydronephrosis was easy in all cases and could evaluate of its severity, renal function and obstruction site with high accuracy. 5.Wilms' tumor and neuroblastoma were relatively well differentiated by their characteristic CT features; such as location, shape, margin, middle cross, calyceal appearance and calcification, etc. 6.Ovarian and mensentric cysts had similar CT appearance. 7.In other pediatric abdominal masses, CT provided excellent information about anatomic detail, precise extent of tumor and differential diagnostic findings. So, CT is useful imaging modality for the demonstration and diagnosis of abdominal mass lesions in pediatric patients.

  13. Evaluation of the Nova StatSensor® XpressTM Creatinine Point-Of-Care Handheld Analyzer

    Science.gov (United States)

    Kosack, Cara Simone; de Kieviet, Wim; Bayrak, Kubra; Milovic, Anastacija; Page, Anne Laure

    2015-01-01

    Creatinine is a parameter that is required to monitor renal function and is important to follow in patients under treatment with potentially toxic renal drugs, such as the anti-HIV drug Tenofovir. A point of care instrument to measure creatinine would be useful for patients monitoring in resource-limited settings, where more instruments that are sophisticated are not available. The StatSensor Xpress Creatinine (Nova Biomedical Cooperation, Waltham, MA, USA) point of care analyzer was evaluated for its diagnostic performance in indicating drug therapy change. Creatinine was measured in parallel using the Nova StatSensor Xpress Creatinine analyzer and the Vitros 5,1FS (Ortho Clinical Diagnostics, Inc, Rochester, USA), which served as reference standard. The precision (i.e., repeatability and reproducibility) and accuracy of the StatSensor Xpress Creatinine analyzer were calculated using a panel of specimens with normal, low pathological and high pathological values. Two different Nova StatSensor Xpress Creatinine analyzers were used for the assessment of accuracy using repeated measurements. The coefficient of variation of the StatSensor Xpress Creatinine analyzers ranged from 2.3 to 5.9% for repeatability and from 4.2 to 9.0% for between-run reproducibility. The concordance correlation agreement was good except for high values (>600 µmol/L). The Bland-Altman analysis in high pathological specimens suggests that the Nova StatSensor Xpress Creatinine test tends to underestimate high creatinine values (i.e., >600 µmol/L). The Nova StatSensor Xpress Creatinine analyzers showed acceptable to good results in terms of repeatability, inter-device reproducibility and between-run reproducibility over time using quality control reagents. The analyzer was found sufficiently accurate for detecting pathological values in patients (age >10 year) and can be used with a moderate risk of misclassification. PMID:25886375

  14. Evaluation of the Nova StatSensor® Xpress(TM) Creatinine point-of-care handheld analyzer.

    Science.gov (United States)

    Kosack, Cara Simone; de Kieviet, Wim; Bayrak, Kubra; Milovic, Anastacija; Page, Anne Laure

    2015-01-01

    Creatinine is a parameter that is required to monitor renal function and is important to follow in patients under treatment with potentially toxic renal drugs, such as the anti-HIV drug Tenofovir. A point of care instrument to measure creatinine would be useful for patients monitoring in resource-limited settings, where more instruments that are sophisticated are not available. The StatSensor Xpress Creatinine (Nova Biomedical Cooperation, Waltham, MA, USA) point of care analyzer was evaluated for its diagnostic performance in indicating drug therapy change. Creatinine was measured in parallel using the Nova StatSensor Xpress Creatinine analyzer and the Vitros 5,1FS (Ortho Clinical Diagnostics, Inc, Rochester, USA), which served as reference standard. The precision (i.e., repeatability and reproducibility) and accuracy of the StatSensor Xpress Creatinine analyzer were calculated using a panel of specimens with normal, low pathological and high pathological values. Two different Nova StatSensor Xpress Creatinine analyzers were used for the assessment of accuracy using repeated measurements. The coefficient of variation of the StatSensor Xpress Creatinine analyzers ranged from 2.3 to 5.9% for repeatability and from 4.2 to 9.0% for between-run reproducibility. The concordance correlation agreement was good except for high values (>600 µmol/L). The Bland-Altman analysis in high pathological specimens suggests that the Nova StatSensor Xpress Creatinine test tends to underestimate high creatinine values (i.e., >600 µmol/L). The Nova StatSensor Xpress Creatinine analyzers showed acceptable to good results in terms of repeatability, inter-device reproducibility and between-run reproducibility over time using quality control reagents. The analyzer was found sufficiently accurate for detecting pathological values in patients (age >10 year) and can be used with a moderate risk of misclassification.

  15. Evaluation of gas chromatography – electron ionization – full scan high resolution Orbitrap mass spectrometry for pesticide residue analysis

    International Nuclear Information System (INIS)

    Mol, Hans G.J.; Tienstra, Marc; Zomer, Paul

    2016-01-01

    Gas chromatography with electron ionization and full scan high resolution mass spectrometry with an Orbitrap mass analyzer (GC-EI-full scan Orbitrap HRMS) was evaluated for residue analysis. Pesticides in fruit and vegetables were taken as an example application. The relevant aspects for GC-MS based residue analysis, including the resolving power (15,000 to 120,000 FWHM at m/z 200), scan rate, dynamic range, selectivity, sensitivity, analyte identification, and utility of existing EI-libraries, are assessed and discussed in detail. The optimum acquisition conditions in full scan mode (m/z 50–500) were a resolving power of 60,000 and an automatic-gain-control target value of 3E6. These conditions provided (i) an optimum mass accuracy: within 2 ppm over a wide concentration range, with/without matrix, enabling the use of ±5 ppm mass extraction windows (ii) adequate scan speed: minimum 12 scans/peak, (iii) an intra-scan dynamic range sufficient to achieve LOD/LOQs ≤0.5 pg in fruit/vegetable matrices (corresponding to ≤0.5 μg kg"−"1) for most pesticides. EI-Orbitrap spectra were consistent over a very wide concentration range (5 orders) with good match values against NIST (EI-quadrupole) spectra. The applicability for quantitative residue analysis was verified by validation of 54 pesticides in three matrices (tomato, leek, orange) at 10 and 50 μg/kg. The method involved a QuEChERS-based extraction with a solvent switch into iso-octane, and 1 μL hot splitless injection into the GC-HRMS system. A recovery between 70 and 120% and a repeatability RSD <10% was obtained in most cases. Linearity was demonstrated for the range ≤5–250 μg kg"−"1. The pesticides could be identified according to the applicable EU criteria for GC-HRMS (SANTE/11945/2015). GC-EI-full scan Orbitrap HRMS was found to be highly suited for quantitative pesticide residue analysis. The potential of qualitative screening to extend the scope makes it an attractive alternative to

  16. Evaluation of gas chromatography – electron ionization – full scan high resolution Orbitrap mass spectrometry for pesticide residue analysis

    Energy Technology Data Exchange (ETDEWEB)

    Mol, Hans G.J., E-mail: hans.mol@wur.nl; Tienstra, Marc; Zomer, Paul

    2016-09-07

    Gas chromatography with electron ionization and full scan high resolution mass spectrometry with an Orbitrap mass analyzer (GC-EI-full scan Orbitrap HRMS) was evaluated for residue analysis. Pesticides in fruit and vegetables were taken as an example application. The relevant aspects for GC-MS based residue analysis, including the resolving power (15,000 to 120,000 FWHM at m/z 200), scan rate, dynamic range, selectivity, sensitivity, analyte identification, and utility of existing EI-libraries, are assessed and discussed in detail. The optimum acquisition conditions in full scan mode (m/z 50–500) were a resolving power of 60,000 and an automatic-gain-control target value of 3E6. These conditions provided (i) an optimum mass accuracy: within 2 ppm over a wide concentration range, with/without matrix, enabling the use of ±5 ppm mass extraction windows (ii) adequate scan speed: minimum 12 scans/peak, (iii) an intra-scan dynamic range sufficient to achieve LOD/LOQs ≤0.5 pg in fruit/vegetable matrices (corresponding to ≤0.5 μg kg{sup −1}) for most pesticides. EI-Orbitrap spectra were consistent over a very wide concentration range (5 orders) with good match values against NIST (EI-quadrupole) spectra. The applicability for quantitative residue analysis was verified by validation of 54 pesticides in three matrices (tomato, leek, orange) at 10 and 50 μg/kg. The method involved a QuEChERS-based extraction with a solvent switch into iso-octane, and 1 μL hot splitless injection into the GC-HRMS system. A recovery between 70 and 120% and a repeatability RSD <10% was obtained in most cases. Linearity was demonstrated for the range ≤5–250 μg kg{sup −1}. The pesticides could be identified according to the applicable EU criteria for GC-HRMS (SANTE/11945/2015). GC-EI-full scan Orbitrap HRMS was found to be highly suited for quantitative pesticide residue analysis. The potential of qualitative screening to extend the scope makes it an attractive

  17. Preoperative evaluation of renal anatomy and renal masses with helical CT, 3D-CT and 3D-CT angiography.

    Science.gov (United States)

    Toprak, Uğur; Erdoğan, Aysun; Gülbay, Mutlu; Karademir, Mehmet Alp; Paşaoğlu, Eşref; Akar, Okkeş Emrah

    2005-03-01

    The aim of this prospective study was to determine the efficacy of three-dimensional computed tomography (3D-CT) and three-dimensional computed tomographic angiography (3D-CTA) that were reconstructed by using the axial images of the multiphasic helical CT in the preoperative evaluation of renal masses and demonstration of renal anatomy. Twenty patients that were suspected of having renal masses upon initial physical examination and ultrasonographic evaluation were examined through multiphasic helical CT. Two authors executed CT evaluations. Axial images were first examined and then used to reconstruct 3D-CT and 3D- CTA images. Number, location and size of the renal masses and other findings were noted. Renal vascularization and relationships of the renal masses with the neighboring renal structures were further investigated with 3D-CT and 3D-CTA images. Out of 20 patients, 13 had histopathologically proven renal cell carcinoma. The diagnoses of the remaining seven patients were xanthogranulomatous pyelonephritis, abscess, simple cyst, infected cyst, angiomyolipoma, oncocytoma and arteriovenous fistula. In the renal cell carcinoma group, 3 patients had stage I, 7 patients had stage II, and 3 patients had stage III disease. Sizes of renal cell carcinoma masses were between 23 mm to 60 mm (mean, 36 mm). Vascular invasion was shown in 2 renal cell carcinoma patients. Collecting system invasion was identified in 11 of 13 renal cell patients. These radiologic findings were confirmed with surgical specimens. Three-dimensional CT and 3D-CTA are non-invasive, effective imaging techniques for the preoperative evaluation of renal masses.

  18. Experimental evaluation of the objective virtual mass coefficient

    International Nuclear Information System (INIS)

    Heilbron Filho, Paulo Fernando Lavalle

    1984-04-01

    This work is a continuation of many others studies that have been made in the field of two-phase flow, concerning the influence of the void fraction in a parameter known as 'induced mass' that appears in the constitutive equation of the inter-phase force called 'virtual mass force'. The determination of the influence of the void fraction in the induced mass is done using experiment involving a bubble flow in a vertical tube filled with water. Using the two-phase flow model together with some hypothesis concerning the bubble flow experience and the constitutive equation for the virtual mass force, we achieve through the analysis of the filming of the experiment our purpose in determining the influence of the void fraction on the induced mass. (author)

  19. Using Videos To Teach Mass Media and Society from a Critical Perspective.

    Science.gov (United States)

    King, Donna Lee

    2000-01-01

    Explores using videos to teach mass media and society from a critical sociological perspective. Discusses the content of the course from focusing on analysis of corporate capitalism and media producers to analyzing popular media texts on gender, race, the working class, and sexuality. Addresses the evaluation of the course. (CMK)

  20. Long-term evaluation of a Canadian back pain mass media campaign.

    Science.gov (United States)

    Suman, Arnela; Bostick, Geoffrey P; Schopflocher, Donald; Russell, Anthony S; Ferrari, Robert; Battié, Michele C; Hu, Richard; Buchbinder, Rachelle; Gross, Douglas P

    2017-09-01

    This paper evaluates the long-term impact of a Canadian mass media campaign on general public beliefs about staying active when experiencing low back pain (LBP). Changes in beliefs about staying active during an episode of LBP were studied using telephone and web-based surveys. Logistic regression analysis was used to investigate changes in beliefs over time and the effect of exposure to campaign messaging. The percentage of survey respondents agreeing that they should stay active through LBP increased annually from 58.9 to ~72.0%. Respondents reporting exposure to campaign messaging were statistically significantly more likely to agree with staying active than respondents who did not report exposure to campaign messaging (adjusted OR, 95% CI = 1.96, 1.73-2.21). The mass media campaign had continued impact on public LBP beliefs over the course of 7 years. Improvements over time were associated with exposure to campaign messaging.

  1. Evaluation of a mass-balance approach to determine consumptive water use in northeastern Illinois

    Science.gov (United States)

    Mills, Patrick C.; Duncker, James J.; Over, Thomas M.; Marian Domanski,; ,; Engel, Frank

    2014-01-01

    A principal component of evaluating and managing water use is consumptive use. This is the portion of water withdrawn for a particular use, such as residential, which is evaporated, transpired, incorporated into products or crops, consumed by humans or livestock, or otherwise removed from the immediate water environment. The amount of consumptive use may be estimated by a water (mass)-balance approach; however, because of the difficulty of obtaining necessary data, its application typically is restricted to the facility scale. The general governing mass-balance equation is: Consumptive use = Water supplied - Return flows.

  2. Charm mass corrections to the bottomonium mass spectrum

    International Nuclear Information System (INIS)

    Ebert, D.; Faustov, R. N.; Galkin, V. O.

    2002-01-01

    The one-loop corrections to the bottomonium mass spectrum due to the finite charm mass are evaluated in the framework of the relativistic quark model. The obtained corrections are compared with the results of perturbative QCD

  3. Radiologic evaluation of spinal epidural mass

    International Nuclear Information System (INIS)

    Lee, Ho Kyu; Lee, Moon Kyu; Chang, Kee Hyun

    1987-01-01

    It is often difficult to differentiate each pathologic entity among various spinal epidural masses on the radiologic basis. We retrospectively analysed radiologic findings of 67 cases of pathologically proven spinal epidural mass to find out any specific findings of each epidural mass. The results are as follows : 1. Of 67 cases, metastasis (16 cases), epidural abscess (15 cases), neurogenic tumor (16 cases) and meningioma (8 cases) are most common. The others consist of epidural angioma (3 cases), vertebral hemangioma (2 cases), chondrosarcoma (2 cases), fibrosarcoma (1 case), eosinophilic granuloma (1 case), lymphoma (1 case), lipoma (1 case) and lymphoid hyperplasia (1 case). 2. Destruction of the adjacent bone was commonly associated with the epidural mass in metastasis (75%) and epidural abscess (67%). It was also noted in 2 cases of chondrosarcoma, 1 fibrosarcoma and 1 eosinophilic granuloma. 3. Pressure erosion of adjacent bone was demonstrated in neurogenic tumor (75%) and meningioma (25%). 4. Narrowing of intervertebral space was seen in only 27% of epidural abscess. 5. The paraspinal tumor was associated in 67% of metastasis, 80% of epidural abscess, 75% of neurogenic tumor, 33% of meningioma. It was also seen in 2 cases of chondrosarcoma, 1 fibrosarcoma and 1 eosinophilic granuloma. 6. The intradural tumor was associated in 50% of neurogenic tumor and 67% of meningioma. 7. On axial CT image, most of the epidural mass shows eccentric location with displacing dural sac to the opposite side. The diseases that occasionally show encircling location are metastasis, epidural abscess, vertebral hemangioma, chondrosarcoma, eosinophilic granuloma, and lymphoma. Neurogenic tumor only shows multicentric location. 8. The disease extent more than height of one vertebral body was seen in 80% of epidural abscess, 58% of neurogenic tumor, 100% of epidural angioma. It was also seen in 2 cases of chondrosarcoma, 1 fibrosarcoma, 1 eosinophilic granuloma, 1 lymphoma, 1

  4. 21 CFR 868.1670 - Neon gas analyzer.

    Science.gov (United States)

    2010-04-01

    ... patient. The device may use techniques such as mass spectrometry or thermal conductivity. (b... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neon gas analyzer. 868.1670 Section 868.1670 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL...

  5. Galaxy-M: a Galaxy workflow for processing and analyzing direct infusion and liquid chromatography mass spectrometry-based metabolomics data.

    Science.gov (United States)

    Davidson, Robert L; Weber, Ralf J M; Liu, Haoyu; Sharma-Oates, Archana; Viant, Mark R

    2016-01-01

    Metabolomics is increasingly recognized as an invaluable tool in the biological, medical and environmental sciences yet lags behind the methodological maturity of other omics fields. To achieve its full potential, including the integration of multiple omics modalities, the accessibility, standardization and reproducibility of computational metabolomics tools must be improved significantly. Here we present our end-to-end mass spectrometry metabolomics workflow in the widely used platform, Galaxy. Named Galaxy-M, our workflow has been developed for both direct infusion mass spectrometry (DIMS) and liquid chromatography mass spectrometry (LC-MS) metabolomics. The range of tools presented spans from processing of raw data, e.g. peak picking and alignment, through data cleansing, e.g. missing value imputation, to preparation for statistical analysis, e.g. normalization and scaling, and principal components analysis (PCA) with associated statistical evaluation. We demonstrate the ease of using these Galaxy workflows via the analysis of DIMS and LC-MS datasets, and provide PCA scores and associated statistics to help other users to ensure that they can accurately repeat the processing and analysis of these two datasets. Galaxy and data are all provided pre-installed in a virtual machine (VM) that can be downloaded from the GigaDB repository. Additionally, source code, executables and installation instructions are available from GitHub. The Galaxy platform has enabled us to produce an easily accessible and reproducible computational metabolomics workflow. More tools could be added by the community to expand its functionality. We recommend that Galaxy-M workflow files are included within the supplementary information of publications, enabling metabolomics studies to achieve greater reproducibility.

  6. Multi-Center Evaluation of the Automated Immunohematology Instrument, the ORTHO VISION Analyzer.

    Science.gov (United States)

    Aysola, Agnes; Wheeler, Leslie; Brown, Richard; Denham, Rebecca; Colavecchia, Connie; Pavenski, Katerina; Krok, Elizabeth; Hayes, Chelsea; Klapper, Ellen

    2017-02-01

    ORTHO VISION Analyzer (Vision), is an immunohematology instrument using ID-MT gel card technology with digital image processing. It has a continuous, random sample access with STAT priority processing. The efficiency and ease of operation of Vision was evaluated at 5 medical centers. De-identified patient samples were tested on the ORTHO ProVue Analyzer (ProVue) and repeated on the Vision mimicking the daily workload pattern. Turnaround times (TAT) were collected and compared. Operators rated key features of the analyzer on a scale of 1 to 5. A total of 507 samples were tested on both instruments at the 5 trial sites. The mean TAT (SD) were 31.6 minutes (5.5) with Vision and 35.7 minutes (8.4) with ProVue, which renders a 12% reduction. Type and screens were performed on 381 samples; the mean TAT (SD) was 32.2 minutes (4.5) with Vision and 37.0 minutes (7.4) with ProVue. Antibody identification with eleven panel cells was performed on 134 samples on Vision; TAT (SD) was 43.2 minutes (8.3). The installation, training, configuration, maintenance and validation processes are all streamlined to provide a short implementation time. The average rating of main functions by the operators was 4.1 to 4.8. Opportunities for improvement, such as flexibility with editing QC results, maintenance schedule, and printing options were identified. The capabilities to perform serial dilutions, to accept pediatric tubes, and review results by e-Connectivity are enhancements over the ProVue. Vision provides shorter TAT compared to ProVue. Every site described a positive experience using Vision. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  7. THEORETICAL FOUNDATIONS EFFICIENT MASS VALUATION

    Directory of Open Access Journals (Sweden)

    Koshel A.

    2016-08-01

    Full Text Available In the article the theoretical basis for determining the effectiveness of mass valuation of land in present-day conditions are described. The concept defenitsy effect and effectiveness as economic categories and their classification values for mass valuation of land are presented. The effectiveness of mass valuation of land in the settlements defines the structure of local budget and economic activities undertaken by local authorities on the basis of the results of the mass appraisal of real estate. Mass valuation is regular and it is characterized by high degree of standardization of procedures and a significant increase in the role of statistical methods for processing data related to the use of the most significant factors influencing the parameters of the object to its cost, as well as the need to determine the value of the objective laws change equivalent, which is only possible when using economic and mathematical methods and statistical analysis. Quality control results of mass valuation carried out principally in other ways, as obtained by applying statistical machine results can be checked as soon statistical methods. This shows the relevance of research topic and lack of elaboration for Ukraine problems of efficiency of mass land valuation. Scientific research conducted through the use of the dialectical method and techniques of abstraction, comparative analysis and synthesis, the article various models and methods of valuation of land for taxation purposes are analyzed. In addition, the group explored methods used, comparisons, and more. In economic theory and practice problems and determine the effect of efficiency aimed at profit is quite relevant. Economists consider cost-effectiveness, such as economic efficiency. In this case, the production can be attributed to the activities to conduct and organization of mass valuation of land. This pushes many different positions on criteria and indicators of economic efficiency, the

  8. C. T. criteria of the differential diagnosis in primary retroperitoneal masses

    Energy Technology Data Exchange (ETDEWEB)

    Pistolesi, G.F.; Procacci, C.; Caudana, R.; Bergamo Andreis, I.A.; Manera, V.; Recla, M.; Grasso, G.; Florio, C.

    1984-05-01

    This personal series of 44 primary retroperitoneal masses (P.R.P.M.) studied by C.T. is analyzed. The reliability of C.T. in the identification (44/44), characterization (43/44) and origin evaluation (41/44) of P.R.P.M. has been absolutely satisfactory. In particular, those criteria of C.T. diagnosis which may be utilized in the evaluation of the origin of upper abdominal masses are thoroughly described. The evaluation of the involvement (non invasive; invasive) of adjacent viscera has been achieved in 22/38 P.R.P.M. verified at operation. The evaluation of tumour resectability has been less reliable due to the high incidence of under-diagnosis (60% in our personal experience). C.T. may be used in addition as an aid to different diagnostic techniques (percutaneous guided needle biopsy) or to therapy (drainage of retroperitoneal abscesses). C.T. is absolutely necessary in the follow-up of P.R.P.M. after surgery, radiotherapy or chemotherapy.

  9. C.T. criteria of the differential diagnosis in primary retroperitoneal masses

    International Nuclear Information System (INIS)

    Pistolesi, G.F.; Procacci, C.; Caudana, R.; Bergamo Andreis, I.A.; Manera, V.; Recla, M.; Grasso, G.; Florio, C.

    1984-01-01

    This personal series of 44 primary retroperitoneal masses (P.R.P.M.) studied by C.T. is analyzed. The reliability of C.T. in the identification (44/44), characterization (43/44) and origin evaluation (41/44) of P.R.P.M. has been absolutely satisfactory. In particular, those criteria of C.T. diagnosis which may be utilized in the evaluation of the origin of upper abdominal masses are thoroughly described. The evaluation of the involvement (non invasive; invasive) of adjacent viscera has been achieved in 22/38 P.R.P.M. verified at operation. The evaluation of tumour resectability has been less reliable due to the high incidence of under-diagnosis (60% in our personal experience). C.T. may be used in addition as an aid to different diagnostic techniques (percutaneous guided needle biopsy) or to therapy (drainage of retroperitoneal abscesses). C.T. is absolutely necessary in the follow-up of P.R.P.M. after surgery, radiotherapy or chemotherapy. (orig.)

  10. High-sensitive portable ASE-2 X-ray analyzer of sulfur in mineral oil

    International Nuclear Information System (INIS)

    Anchugov, I.S.; Goganov, A.D.; Plotnikov, R.I.

    2007-01-01

    The high-sensitivity ASE-2 analyzer of sulfur on the basis of existing ASE-I device is designed. ASE-2 analyzer realizes a standard method of energy dispersion X-ray fluorescent determinations of a sulfur mass fraction in mineral oil and allows to carry out the quantitative determination of sulfur in hydrocarbonic raw material and fuel in a 0.002-5 mass.% range [ru

  11. Ultrasound for initial evaluation and triage of clinically suspicious soft-tissue masses

    International Nuclear Information System (INIS)

    Lakkaraju, A.; Sinha, R.; Garikipati, R.; Edward, S.; Robinson, P.

    2009-01-01

    Aim: To evaluate the efficacy of ultrasound as a first-line investigation in patients with a clinical soft-tissue mass. Methods: Three hundred and fifty-eight consecutive patients (155 male, 203 female, mean age 48 years) referred from primary and secondary care with soft-tissue masses underwent ultrasound evaluation. Five radiologists performed ultrasound using a 10-15 MHz linear transducer and recorded the referrer diagnosis, history, lesion size, anatomical location and depth, internal echogenicity, external margins (well-defined rim or infiltrative), and vascularity on power Doppler (absent or present, if present the pattern was listed as either linear or disorganized). A provisional ultrasound diagnosis was made using one of eight categories. Benign categories (categories 1-5) were referred back to a non-sarcoma specialist or original referrer for observation. Indeterminate or possible sarcomas (categories 6-8) were referred for magnetic resonance imaging (MRI) within 14 days. Additionally category 8 lesions were referred to the regional sarcoma service. Institutional and regional database follow-up was performed. Results: Two hundred and eighty-four of the 358 (79%) lesions were classified as benign (categories 1-5). On follow-up 15 of the 284 patients were re-referred but none (284/284) had a malignancy on follow-up (24-30 months). Overall at ultrasound 33 lesions were larger than 5 cm, 42 lesions were deep to deep fascia with 20 showing both features. In this subgroup of 95 patients there were six malignant tumours with the rest benign. Seventy-three of the 358 patients underwent MRI; the results of which indicated that there were 60 benign or non-tumours, 10 possible sarcomas, and three indeterminate lesions. Overall six of 12 (6/358, 1.68% of total patients) lesions deemed to represent possible sarcomas on imaging were sarcomas. Conclusion: Ultrasound is an effective diagnostic triage tool for the evaluation of soft-tissue masses referred from primary

  12. Pseudocode Interpreter (Pseudocode Integrated Development Environment with Lexical Analyzer and Syntax Analyzer using Recursive Descent Parsing Algorithm

    Directory of Open Access Journals (Sweden)

    Christian Lester D. Gimeno

    2017-11-01

    Full Text Available –This research study focused on the development of a software that helps students design, write, validate and run their pseudocode in a semi Integrated Development Environment (IDE instead of manually writing it on a piece of paper.Specifically, the study aimed to develop lexical analyzer or lexer, syntax analyzer or parser using recursive descent parsing algorithm and an interpreter. The lexical analyzer reads pseudocodesource in a sequence of symbols or characters as lexemes.The lexemes are then analyzed by the lexer that matches a pattern for valid tokens and passes to the syntax analyzer or parser. The syntax analyzer or parser takes those valid tokens and builds meaningful commands using recursive descent parsing algorithm in a form of an abstract syntax tree. The generation of an abstract syntax tree is based on the specified grammar rule created by the researcher expressed in Extended Backus-Naur Form. The Interpreter takes the generated abstract syntax tree and starts the evaluation or interpretation to produce pseudocode output. The software was evaluated using white-box testing by several ICT professionals and black-box testing by several computer science students based on the International Organization for Standardization (ISO 9126 software quality standards. The overall results of the evaluation both for white-box and black-box were described as “Excellent in terms of functionality, reliability, usability, efficiency, maintainability and portability”.

  13. PLT and PDX perpendicular charge-exchange analyzers

    International Nuclear Information System (INIS)

    Mueller, D.; Hammett, G.W.; McCune, D.C.

    1986-01-01

    The perpendicular charge-exchange systems used on the poloidal divertor experiment and the Princeton large torus are comprised of ten-channel, mass-resolved, charge-exchange analyzers. Results from these systems indicate that instrumental effects can lead to erroneous temperature measurements during deuterium neutral beam injection or at low hydrogen concentrations

  14. Mini ion trap mass spectrometer

    Science.gov (United States)

    Dietrich, D.D.; Keville, R.F.

    1995-09-19

    An ion trap is described which operates in the regime between research ion traps which can detect ions with a mass resolution of better than 1:10{sup 9} and commercial mass spectrometers requiring 10{sup 4} ions with resolutions of a few hundred. The power consumption is kept to a minimum by the use of permanent magnets and a novel electron gun design. By Fourier analyzing the ion cyclotron resonance signals induced in the trap electrodes, a complete mass spectra in a single combined structure can be detected. An attribute of the ion trap mass spectrometer is that overall system size is drastically reduced due to combining a unique electron source and mass analyzer/detector in a single device. This enables portable low power mass spectrometers for the detection of environmental pollutants or illicit substances, as well as sensors for on board diagnostics to monitor engine performance or for active feedback in any process involving exhausting waste products. 10 figs.

  15. Evaluation of false positive responses by mass spectrometry and ion mobility spectrometry for the detection of trace explosives in complex samples

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, C.L., E-mail: clcrawf@sandia.gov; Hill, H.H.

    2013-09-17

    Graphical abstract: -- Highlights: •First study to use (−)SESI-IM-TOFMS to analyze complex mixtures of personal care products. •The study demonstrated, by identifying mobility and mass interferents with explosive signatures, which, if used separately, neither IMS nor MS alone would prevent every false positive for explosives when detected in the presence of a complex sample matrix. •Ingredients in common household cleaning products were shown to either enhance or suppress the ionization of explosives in a SESI-IM-TOFMS analysis. •Mobility separation provided real-time separation of ion species that indicated overlapping isotope peak patterns -- Abstract: Secondary electrospray ionization-ion mobility-time of flight mass spectrometry (SESI-IM-TOFMS) was used to evaluate common household products and food ingredients for any mass or mobility responses that produced false positives for explosives. These products contained ingredients which shared the same mass and mobility drift time ranges as the analyte ions for common explosives. The results of this study showed that the vast array of compounds in these products can cause either mass or mobility false positive responses. This work also found that two ingredients caused either enhanced or reduced ionization of the target analytes. Another result showed that an IMS can provide real-time separation of ion species that impede accurate mass identifications due to overlapping isotope peak patterns. The final result of this study showed that, when mass and mobility values were used to identify an ion, no false responses were found for the target explosives. The wider implication of these results is that the possibility exists for even greater occurrences of false responses from complex mixtures found in common products. Neither IMS nor MS alone can provide 100% assurance from false responses. IMS, due to its low cost, ease of operation, rugged reliability, high sensitivity and tunable selectivity, will remain

  16. A communicational framework for evaluating interaction with IT by analyzing user-reception of electronic texts

    DEFF Research Database (Denmark)

    Wentzer, Helle

    2006-01-01

    Interpreting IT as a medium for continuous communication across time and place of the communicators offers a way of analyzing the effect of IT in concrete practices. The users’ readings determine the actual communication with IT. A poetics of how meaning is translated from one person to another...... through semiotic texts is presented, termed the poetics of the e-text. The poetics of the e-text offers a meta-communicational framework for identifying user constraints in the possibilities of interacting with the system. Identifying communicational problems with ICT-mediated interactions again offer...... grounds for redesigning and re-author the e-text. The poetics of the e-text are subsequently applied as a method of analyzing user-reception and evaluating the interaction with ICT. Examples are given from user-receptions of collaborating with ICT in home care, Denmark....

  17. Evaluation of ultrasound in the diagnosis of parotid gland masses

    Directory of Open Access Journals (Sweden)

    Parotid gland

    1999-08-01

    Full Text Available In order to evaluate accuracy and usefulness of sonography and choose it as preliminary investigation method in pathologic processes of parotid gland, 50 patients were studied in duration of 16 months. The lesions were evaluated with ultrasound and sonographic images were obtained before surgery and then were compared with pathologic results after surgery. All lesions were detected with sonography. This method could differentiate intraglandular from extraglandular lesions with accuracy of 100%. Except one case of lipomatosis which was hyperechoic, all other lesions of parotid gland were hypoechoic. All lesions with sharp and well-defined borders were benign whereas malignant processes had ill-defined borders. The results obtained show that sonography is a reliable diagnostic method to differentiate benign from malignant lesions and it has a high diagnostic value to detect warthin's tumor, plemorphic adenoma, Sjogren's syndrome and lipomatosis. Presence of calcification in a parotid mass of young patient with high probabye is related to cavernous hemangioma.

  18. Easy Extraction Method To Evaluate δ13C Vanillin by Liquid Chromatography-Isotopic Ratio Mass Spectrometry in Chocolate Bars and Chocolate Snack Foods.

    Science.gov (United States)

    Bononi, Monica; Quaglia, Giancarlo; Tateo, Fernando

    2015-05-20

    An easy extraction method that permits the use of a liquid chromatography-isotopic ratio mass spectrometry (LC-IRMS) system to evaluate δ(13)C of vanillin in chocolate products and industrial flavorings is presented. The method applies the determination of stable isotopes of carbon to discriminate between natural vanillin from vanilla beans and vanillin from other sources (mixtures from beans, synthesis, or biotechnology). A series of 13 chocolate bars and chocolate snack foods available on the Italian market and 8 vanilla flavorings derived from industrial quality control processes were analyzed. Only 30% of products considered in this work that declared "vanilla" on the label showed data that permitted the declaration "vanilla" according to European Union (EU) Regulation 1334/2008. All samples not citing "vanilla" or "natural flavoring" on the label gave the correct declaration. The extraction method is presented with data useful for statistical evaluation.

  19. Linear Ion Traps in Space: The Mars Organic Molecule Analyzer (MOMA) Instrument and Beyond

    Science.gov (United States)

    Arevalo, Ricardo; Brinckerhoff, William; Mahaffy, Paul; van Amerom, Friso; Danell, Ryan; Pinnick, Veronica; Li, Xiang; Hovmand, Lars; Getty, Stephanie; Grubisic, Andrej; Goesmann, Fred; Cottin, Hervé

    2015-11-01

    Historically, quadrupole mass spectrometer (QMS) instruments have been used to explore a wide survey of planetary targets in our solar system, from Venus (Pioneer Venus) to Saturn (Cassini-Huygens). However, linear ion trap (LIT) mass spectrometers have found a niche as smaller, versatile alternatives to traditional quadrupole analyzers.The core astrobiological experiment of ESA’s ExoMars Program is the Mars Organic Molecule Analyzer (MOMA) onboard the ExoMars 2018 rover. The MOMA instrument is centered on a linear (or 2-D) ion trap mass spectrometer. As opposed to 3-D traps, LIT-based instruments accommodate two symmetrical ion injection pathways, enabling two complementary ion sources to be used. In the case of MOMA, these two analytical approaches are laser desorption mass spectrometry (LDMS) at Mars ambient pressures, and traditional gas chromatography mass spectrometry (GCMS). The LIT analyzer employed by MOMA also offers: higher ion capacity compared to a 3-D trap of the same volume; redundant detection subassemblies for extended lifetime; and, a link to heritage QMS designs and assembly logistics. The MOMA engineering test unit (ETU) has demonstrated the detection of organics in the presence of wt.%-levels of perchlorate, effective ion enhancement via stored waveform inverse Fourier transform (SWIFT), and derivation of structural information through tandem mass spectrometry (MS/MS).A more progressive linear ion trap mass spectrometer (LITMS), funded by the NASA ROSES MatISSE Program, is being developed at NASA GSFC and promises to augment the capabilities of the MOMA instrument by way of: an expanded mass range (i.e., 20 - 2000 Da); detection of both positive and negative ions; spatially resolved (<1 mm) characterization of individual rock core layers; and, evolved gas analysis and GCMS with pyrolysis up to 1300° C (enabling breakdown of refractory phases). The Advanced Resolution Organic Molecule Analyzer (AROMA) instrument, being developed through NASA

  20. Mass preserving image registration

    DEFF Research Database (Denmark)

    Gorbunova, Vladlena; Sporring, Jon; Lo, Pechin Chien Pau

    2010-01-01

    The paper presents results the mass preserving image registration method in the Evaluation of Methods for Pulmonary Image Registration 2010 (EMPIRE10) Challenge. The mass preserving image registration algorithm was applied to the 20 image pairs. Registration was evaluated using four different...

  1. Performance evaluation of the Abbott CELL-DYN Emerald for use as a bench-top analyzer in a research setting.

    Science.gov (United States)

    Khoo, T-L; Xiros, N; Guan, F; Orellana, D; Holst, J; Joshua, D E; Rasko, J E J

    2013-08-01

    The CELL-DYN Emerald is a compact bench-top hematology analyzer that can be used for a three-part white cell differential analysis. To determine its utility for analysis of human and mouse samples, we evaluated this machine against the larger CELL-DYN Sapphire and Sysmex XT2000iV hematology analyzers. 120 human (normal and abnormal) and 30 mouse (normal and abnormal) samples were analyzed on both the CELL-DYN Emerald and CELL-DYN Sapphire or Sysmex XT2000iV analyzers. For mouse samples, the CELL-DYN Emerald analyzer required manual recalibration based on the histogram populations. Analysis of the CELL-DYN Emerald showed excellent precision, within accepted ranges (white cell count CV% = 2.09%; hemoglobin CV% = 1.68%; platelets CV% = 4.13%). Linearity was excellent (R² ≥ 0.99), carryover was minimal (laboratories or as a backup system in larger laboratories. © 2012 John Wiley & Sons Ltd.

  2. EVALUATION OF RIGHT ILIAC FOSSA MASS-A RETROSPECTIVE STUDY

    OpenAIRE

    Raja Billy Graham; Vijayabhasker

    2016-01-01

    Mass in right iliac fossa is one of the common clinical surgical entity with varied etiologies, involving intra peritoneal organs like vermiform appendix, caucus, ileum, retroperitoneal structures like kidneys, blood vessels etc., and abdominal wall masses like desmoids tumor. To know the etiology and the various pattern of presentation of right iliac fossa mass in our institution a retrospective study was designed including all adult patients diagnosed to have a mass in right ili...

  3. Methodology and resources for the evaluation of the construction of knowledge about the concept of density and specific mass

    OpenAIRE

    Tânia Inácio de Oliveira; Nádia Vilela Pereira; Cláudio Boghi; Juliano Schimiguel; Dorlivete Moreira Shitsuka

    2017-01-01

    Abstract: The teaching of physics concepts involves the construction of knowledge in the students' minds. The aim of this article is to present a case report of teaching density and specific mass concepts in high school technical education classes. The study analyzes the results of the construction of methodology and development of a product so that teachers of Physics can give their students the construction of the concept of density of objects and the specific mass of the substances and per...

  4. Effect of fat mass and lean mass on bone mineral density in postmenopausal and perimenopausal Thai women

    Directory of Open Access Journals (Sweden)

    Namwongprom S

    2013-02-01

    Full Text Available Sirianong Namwongprom,1 Sattaya Rojanasthien,2 Ampica Mangklabruks,3 Supasil Soontrapa,4 Chanpen Wongboontan,5 Boonsong Ongphiphadhanakul61Clinical Epidemiology Program and Department of Radiology, 2Department of Orthopaedics, 3Department of Internal Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, 4Department of Orthopaedics, Faculty of Medicine, Khon Kaen University, Khon Kaen, 5Department of Radiology, Faculty of Medicine, Chiang Mai University, Chiang Mai, 6Department of Internal Medicine, Faculty of Medicine, Ramathibodi Hospital, Mahidol University, Bangkok, ThailandBackground: The purpose of this study was to investigate the association between fat mass, lean mass, and bone mineral density (BMD in postmenopausal and perimenopausal Thai women.Methods: A cross-sectional study was conducted in 1579 healthy Thai women aged 40–90 years. Total body, lumbar spine, total femur, and femoral neck BMD and body composition were measured by dual x-ray absorptiometry. To evaluate the associations between fat mass and lean mass and various measures of BMD, multivariable linear regression models were used to estimate the regression coefficients for fat mass and lean mass, first in separate equations and then with both fat mass and lean mass in the same equation.Results: Among the study population, 1448 subjects (91.7% were postmenopausal and 131 (8.3% were perimenopausal. In postmenopausal women, after controlling for age, height, and duration of menopause, both fat mass and lean mass were positively correlated with BMD when they were analyzed independently of each other. When included in the same equation, both fat mass and lean mass continued to show a positive effect, but lean mass had a significantly greater impact on BMD than fat mass at all regions except for total body. Lean mass but not fat mass had a positive effect on BMD at all skeletal sites except the lumbar spine, after controlling for age and height in perimenopausal

  5. MASS TRANSFER IN PORE STRUCTURES OF SUPPORTED CATALYSTS

    Directory of Open Access Journals (Sweden)

    F.R.C. Silva

    1997-09-01

    Full Text Available The effects of gas-solid interaction and mass transfer in fixed-bed systems of supported catalysts were analyzed for g -Al2O3 (support and Cu/g -Al2O3 (catalyst systems. Evaluations of the mass transfer coefficients in the macropores and of the diffusivity in the micropores, as formed by the crystallite agglomerates of the metallic phases, were obtained. Dynamic experiments with gaseous tracers permitted the quantification of the parameters based on models for these two pore structures. With a flow in a range of 18 cm3 s-1 to 39.98 cm3 s-1 at 45oC, 65oC and 100oC, mass transfer coefficients km =4.33x10-4 m s-1 to 7.38x10-4 m s-1 for macropore structures and diffusivities Dm =1.29x10-11 m2 s-1 to 5.35x10-11 m2 s-1 for micropore structures were estimated

  6. Testing and Validation of Computational Methods for Mass Spectrometry.

    Science.gov (United States)

    Gatto, Laurent; Hansen, Kasper D; Hoopmann, Michael R; Hermjakob, Henning; Kohlbacher, Oliver; Beyer, Andreas

    2016-03-04

    High-throughput methods based on mass spectrometry (proteomics, metabolomics, lipidomics, etc.) produce a wealth of data that cannot be analyzed without computational methods. The impact of the choice of method on the overall result of a biological study is often underappreciated, but different methods can result in very different biological findings. It is thus essential to evaluate and compare the correctness and relative performance of computational methods. The volume of the data as well as the complexity of the algorithms render unbiased comparisons challenging. This paper discusses some problems and challenges in testing and validation of computational methods. We discuss the different types of data (simulated and experimental validation data) as well as different metrics to compare methods. We also introduce a new public repository for mass spectrometric reference data sets ( http://compms.org/RefData ) that contains a collection of publicly available data sets for performance evaluation for a wide range of different methods.

  7. Relativistic time-dependent Fermion-mass renormalization using statistical regularization

    Science.gov (United States)

    Kutnink, Timothy; McMurray, Christian; Santrach, Amelia; Hockett, Sarah; Barcus, Scott; Petridis, Athanasios

    2017-09-01

    The time-dependent electromagnetically self-coupled Dirac equation is solved numerically by means of the staggered-leap-frog algorithm with reflecting boundary conditions. The stability region of the method versus the interaction strength and the spatial-grid size over time-step ratio is established. The expectation values of several dynamic operators are then evaluated as functions of time. These include the fermion and electromagnetic energies and the fermion dynamic mass. There is a characteristic, non-exponential, oscillatory dependence leading to asymptotic constants of these expectation values. In the case of the fermion mass this amounts to renormalization. The dependence of the expectation values on the spatial-grid size is evaluated in detail. Furthermore, the contribution of positive and negative energy states to the asymptotic values and the gauge fields is analyzed. Statistical regularization, employing a canonical ensemble whose temperature is the inverse of the grid size, is used to remove the grid-size and momentum-dependence and produce a finite result in the continuum limit.

  8. Outline and results of study on excavation response of rock mass around shaft in shaft excavation effects project

    International Nuclear Information System (INIS)

    Sugihara, Kozo; Matsui, Hiroya; Sato, Toshinori

    1993-01-01

    A shaft, with a diameter of 6 m and a depth of 150 m, has been newly excavated in sedimentary rock and excavation response of rock mass around the shaft has been measured and analyzed. Excavation response has been evaluated based on the results of measurement of rock mass movement, such as displacement and strain, and change of rock property, such as deformability and permeability. This study indicates that rock property has been changed with in about 1 m from the shaft wall, and rock mass movement and property change has been influenced by rock facies, fracture and re-distributed stress. The relation between property change and these factors is remained to be evaluated in future study. (author)

  9. Evaluation of axial pile bearing capacity based on pile driving analyzer (PDA) test using Neural Network

    Science.gov (United States)

    Maizir, H.; Suryanita, R.

    2018-01-01

    A few decades, many methods have been developed to predict and evaluate the bearing capacity of driven piles. The problem of the predicting and assessing the bearing capacity of the pile is very complicated and not yet established, different soil testing and evaluation produce a widely different solution. However, the most important thing is to determine methods used to predict and evaluate the bearing capacity of the pile to the required degree of accuracy and consistency value. Accurate prediction and evaluation of axial bearing capacity depend on some variables, such as the type of soil, diameter, and length of pile, etc. The aims of the study of Artificial Neural Networks (ANNs) are utilized to obtain more accurate and consistent axial bearing capacity of a driven pile. ANNs can be described as mapping an input to the target output data. The method using the ANN model developed to predict and evaluate the axial bearing capacity of the pile based on the pile driving analyzer (PDA) test data for more than 200 selected data. The results of the predictions obtained by the ANN model and the PDA test were then compared. This research as the neural network models give a right prediction and evaluation of the axial bearing capacity of piles using neural networks.

  10. Simultaneous mass detection for direct inlet mass spectrometry

    International Nuclear Information System (INIS)

    Gordon, R.L.

    1979-05-01

    The evolution of analytical techniques for application in trace analysis has led to interest in practical methods for real-time monitoring. Direct inlet mass spectrometry (DIMS) has been the subject of considerable activity in recent years. A DIMS instrument is described which consists of an inlet system designed to permit particles entrained in the inlet air stream to strike a hot, oxidized rhenium filament which serves as a surface ionization source. A mass analyzer and detection system then permits identification of the elemental composition of particulates which strike the filament

  11. Direct analysis of samples by mass spectrometry: From elements to bio-molecules using laser ablation inductively couple plasma mass spectrometry and laser desorption/ionization mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Perdian, David C. [Iowa State Univ., Ames, IA (United States)

    2009-01-01

    Mass spectrometric methods that are able to analyze solid samples or biological materials with little or no sample preparation are invaluable to science as well as society. Fundamental research that has discovered experimental and instrumental parameters that inhibit fractionation effects that occur during the quantification of elemental species in solid samples by laser ablation inductively coupled plasma mass spectrometry is described. Research that determines the effectiveness of novel laser desorption/ionization mass spectrometric methods for the molecular analysis of biological tissues at atmospheric pressure and at high spatial resolution is also described. A spatial resolution is achieved that is able to analyze samples at the single cell level.

  12. The pitfalls of ultrasonography in the evaluation of soft tissue masses

    International Nuclear Information System (INIS)

    Kwok, Henry CK.; Pinto, Clinton H.; Doyle, Anthony J.

    2012-01-01

    Ultrasonography is associated with a high error rate in the evaluation of soft tissue masses. The purposes of this study were to examine the nature of the diagnostic errors and to identify areas in which reporting could be improved. Patients who had soft tissue tumours and received ultrasonography during a 10-year period (1999–2009) were identified from a local tumour registry. The sonographic and pathological diagnoses were categorised as either ‘benign’ or ‘non-benign’. The accuracy of ultrasonography was assessed by correlating the sonographic with the pathological diagnostic categories. Recommendations from radiologists, where offered, were assessed for their appropriateness in the context of the pathological diagnosis. One hundred seventy-five patients received ultrasonography, of which 60 had ‘non-benign’ lesions and 115 had ‘benign’ lesions. Ultrasonography correctly diagnosed 35 and incorrectly diagnosed seven of the 60 ‘non-benign’ cases, and did not suggest a diagnosis in 18 cases. Most of the diagnostic errors related to misdiagnosing soft tissue tumours as haematomas (four out of seven). Recommendations for further management were offered by the radiologists in 144 cases, of which 52 had ‘non-benign’ pathology. There were eight ‘non-benign’ cases where no recommendation was offered, and the sonographic diagnosis was either incorrect or unavailable. Ultrasonography lacks accuracy in the evaluation of soft tissue masses. Ongoing education is required to improve awareness of the limitations with its use. These limitations should be highlighted to the referrers, especially those who do not have specific training in this area.

  13. Higgs-boson masses and mixing matrices in the NMSSM. Analysis of on-shell calculations

    Energy Technology Data Exchange (ETDEWEB)

    Drechsel, Peter; Weiglein, Georg [Deutsches Elektronen-Synchrotron (DESY), Hamburg (Germany); Groeber, Ramona [Durham Univ. (United Kingdom). Inst. for Particle Physics Phenomenology; INFN, Sezione di Roma Tre (Italy); Heinemeyer, Sven [Univ. Autonoma de Madrid (UAM/CSIC) (Spain). Inst. de Fisica Teorica; Instituto de Fisica de Cantabria (CSIC-UC), Santander (Spain); UAM + CSIC Campus of International Excellence, Madrid (Spain); Muehlleitner, Milada [Karlsruhe Institute of Technology, Karlsruhe (Germany). Inst. for Theoretical Physics; Rzehak, H. [Univ. of Southern Denmark, Odense (Denmark). CP3-Origins

    2016-12-22

    We analyze the Higgs-boson masses and mixing matrices in the NMSSM based on an on-shell (OS) renormalization of the gauge-boson and Higgs-boson masses and the parameters of the top/scalar top sector. We compare the implementation of the OS calculations in the codes NMSSMCALC and NMSSM-FeynHiggs up to O(α{sub t}α{sub s}). We identify the sources of discrepancies at the one- and at the two-loop level. Finally we compare the OS and DR evaluation as implemented in NMSSMCALC. The results are important ingredients for an estimate of the theoretical precision of Higgs-boson mass calculations in the NMSSM.

  14. Higgs-boson masses and mixing matrices in the NMSSM: analysis of on-shell calculations

    Energy Technology Data Exchange (ETDEWEB)

    Drechsel, P.; Weiglein, G. [DESY, Hamburg (Germany); Groeber, R. [Durham University, Department of Physics, Institute for Particle Physics Phenomenology, Durham (United Kingdom); INFN, Sezione di Roma Tre, Rome (Italy); Heinemeyer, S. [Campus of International Excellence UAM+CSIC, Madrid (Spain); Universidad Autonoma de Madrid, Instituto de Fisica Teorica, (UAM/CSIC), Madrid (Spain); Instituto de Fisica de Cantabria (CSIC-UC), Santander (Spain); Muehlleitner, M. [Karlsruhe Institute of Technology, Institute for Theoretical Physics, Karlsruhe (Germany); Rzehak, H. [University of Southern Denmark, CP3-Origins, Odense M (Denmark)

    2017-06-15

    We analyze the Higgs-boson masses and mixing matrices in the NMSSM based on an on-shell (OS) renormalization of the gauge-boson and Higgs-boson masses and the parameters of the top/scalar top sector. We compare the implementation of the OS calculations in the codes NMSSMCALC and NMSSM-FeynHiggs up to O(α{sub t}α{sub s}). We identify the sources of discrepancies at the one- and at the two-loop level. Finally we compare the OS and DR evaluation as implemented in NMSSMCALC. The results are important ingredients for an estimate of the theoretical precision of Higgs-boson mass calculations in the NMSSM. (orig.)

  15. Methodology for analyzing risk at nuclear facilities

    International Nuclear Information System (INIS)

    Yoo, Hosik; Lee, Nayoung; Ham, Taekyu; Seo, Janghoon

    2015-01-01

    Highlights: • A new methodology for evaluating the risk at nuclear facilities was developed. • Five measures reflecting all factors that should be concerned to assess risk were developed. • The attributes on NMAC and nuclear security culture are included as attributes for analyzing. • The newly developed methodology can be used to evaluate risk of both existing facility and future nuclear system. - Abstract: A methodology for evaluating risks at nuclear facilities is developed in this work. A series of measures is drawn from the analysis of factors that determine risks. Five measures are created to evaluate risks at nuclear facilities. These include the legal and institutional framework, material control, physical protection system effectiveness, human resources, and consequences. Evaluation attributes are developed for each measure and specific values are given in order to calculate the risk value quantitatively. Questionnaires are drawn up on whether or not a state has properly established a legal and regulatory framework (based on international standards). These questionnaires can be a useful measure for comparing the status of the physical protection regime between two countries. Analyzing an insider threat is not an easy task and no methodology has been developed for this purpose. In this study, attributes that could quantitatively evaluate an insider threat, in the case of an unauthorized removal of nuclear materials, are developed by adopting the Nuclear Material Accounting & Control (NMAC) system. The effectiveness of a physical protection system, P(E), could be analyzed by calculating the probability of interruption, P(I), and the probability of neutralization, P(N). In this study, the Tool for Evaluating Security System (TESS) code developed by KINAC is used to calculate P(I) and P(N). Consequence is an important measure used to analyze risks at nuclear facilities. This measure comprises radiological, economic, and social damage. Social and

  16. Linear mass reflectron

    International Nuclear Information System (INIS)

    Mamyrin, B.A.; Shmikk, D.V.

    1979-01-01

    A description and operating principle of a linear mass reflectron with V-form trajectory of ion motion -a new non-magnetic time-of-flight mass spectrometer with high resolution are presented. The ion-optical system of the device consists of an ion source with ionization by electron shock, of accelerating gaps, reflector gaps, a drift space and ion detector. Ions move in the linear mass refraction along the trajectories parallel to the axis of the analyzer chamber. The results of investigations into the experimental device are given. With an ion drift length of 0.6 m the device resolution is 1200 with respect to the peak width at half-height. Small-sized mass spectrometric transducers with high resolution and sensitivity may be designed on the base of the linear mass reflectron principle

  17. Evolution of Mass Functions of Coeval Stars through Wind Mass Loss and Binary Interactions

    NARCIS (Netherlands)

    Schneider, F.R.N.; Izzard, R.G.; Langer, N.; de Mink, S.E.

    2015-01-01

    Accurate determinations of stellar mass functions and ages of stellar populations are crucial to much of astrophysics. We analyze the evolution of stellar mass functions of coeval main-sequence stars, including all relevant aspects of single and binary star evolution. We show that the slope of the

  18. Evaluation of body mass index as a prognostic factor in osteoarthrosis of the knee

    Directory of Open Access Journals (Sweden)

    Fabrício Bolpato Loures

    2016-08-01

    Full Text Available ABSTRACT OBJECTIVE: To evaluate the relationship between patients' body mass index (BMI and the degree of radiographic severity of knee osteoarthrosis. METHOD: 117 patients with gonarthrosis were evaluated prospectively. The patients' BMI was calculated and their knee arthrosis was classified in accordance with the modified Ahlbäck criteria. Kruskal-Wallis analysis of variance (ANOVA was used to evaluate the relationship between these two variables. RESULTS: The group classified as Ahlbäck grade V had significantly higher BMI than the others. CONCLUSION: There is a direct relationship between BMI and the degree of radiographic severity of gonarthrosis. Obesity appears to be directly related to the progression of knee osteoarthrosis.

  19. Solar Probe ANalyzer for Ions - Laboratory Performance

    Science.gov (United States)

    Livi, R.; Larson, D. E.; Kasper, J. C.; Korreck, K. E.; Whittlesey, P. L.

    2017-12-01

    The Parker Solar Probe (PSP) mission is a heliospheric satellite that will orbit the Sun closer than any prior mission to date with a perihelion of 35 solar radii (RS) and an aphelion of 10 RS. PSP includes the Solar Wind Electrons Alphas and Protons (SWEAP) instrument suite, which in turn consists of four instruments: the Solar Probe Cup (SPC) and three Solar Probe ANalyzers (SPAN) for ions and electrons. Together, this suite will take local measurements of particles and electromagnetic fields within the Sun's corona. SPAN-Ai has completed flight calibration and spacecraft integration and is set to be launched in July of 2018. The main mode of operation consists of an electrostatic analyzer (ESA) at its aperture followed by a Time-of-Flight section to measure the energy and mass per charge (m/q) of the ambient ions. SPAN-Ai's main objective is to measure solar wind ions within an energy range of 5 eV - 20 keV, a mass/q between 1-60 [amu/q] and a field of view of 2400x1200. Here we will show flight calibration results and performance.

  20. Sterile insect technique: a field evaluation of the quality of mass-reared fruit flies

    International Nuclear Information System (INIS)

    1985-01-01

    To optimize the use of the sterile insect technique it is essential to establish precise programmes for the evaluation of mass-reared flies in comparison with the natural population. This video presents a programme carried out at the island of Prosida which represents an extremely favourable habitat for the development of the flies; the flies are a new strain mass-reared in the IAEA's Laboratory at Seibersdorf, Austria. The technique employed is the Marked Release Recapture Technique, which consists of colouring a predetermined number of flies with fluorescent powder before they are released, and then recapturing them. This method provides valuable data about the flies' adaptability, orientation to the habitat, motility, sexual activity and reproduction

  1. Sterile insect technique: a field evaluation of the quality of mass-reared fruit flies

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1986-12-31

    To optimize the use of the sterile insect technique it is essential to establish precise programmes for the evaluation of mass-reared flies in comparison with the natural population. This video presents a programme carried out at the island of Prosida which represents an extremely favourable habitat for the development of the flies; the flies are a new strain mass-reared in the IAEA`s Laboratory at Seibersdorf, Austria. The technique employed is the Marked Release Recapture Technique, which consists of colouring a predetermined number of flies with fluorescent powder before they are released, and then recapturing them. This method provides valuable data about the flies` adaptability, orientation to the habitat, motility, sexual activity and reproduction

  2. Evaluations of particulate mass loading from visibility observations and atmospheric turbidity measurements: Pt. 1

    International Nuclear Information System (INIS)

    Tomasi, C.; Vitale, V.

    1984-01-01

    Two extinction models for continental and rural particles were defined by using a very accurate computer programme based on Mie extinction theory for spherical particles. The first extinction model gives several sets of volume extinction coefficients at seven visible and near-infra-red wave-lengths, calculated for twenty-seven Junge-type size distribution curves (with Junge parameter ranging from 1.8 to 4.4) and for eight relative-humidity values of the air. This model also gives the corresponding values of Aangstroem's exponent α and mean particle mass. The second extinction model gives similar sets of data, calculated for two log-normal size distribution curves of tropospheric and large rural particles at five relative-humidity values of the air. These monomodal models can be used to determine bimodal extinction models consisting of variable number fractions of tropospherics and rural particles. Evaluations of the particulate mass loading can be obtained from measurements of visual range and atmospheric turbidity, choosing the most appropriate extinction model on the basis of the spectral features characterizing atmospheric attenuation. Measurements of visibility and atmospheric turbidity in two rural localities of the Po valley were examined by employing both the present extinction models and other extinction models commonly used. The comparison of the results shows that the Junge-type extinction model can be reliably used in cases in which the exponent Junge-type extinction model and bimodal model were found to give realistic evaluations of the lower and upper limits of particulate mass loading

  3. Contributions of natural and anthropogenic radiative forcing to mass loss of Northern Hemisphere mountain glaciers and quantifying their uncertainties.

    Science.gov (United States)

    Hirabayashi, Yukiko; Nakano, Kazunari; Zhang, Yong; Watanabe, Satoshi; Tanoue, Masahiro; Kanae, Shinjiro

    2016-07-20

    Observational evidence indicates that a number of glaciers have lost mass in the past. Given that glaciers are highly impacted by the surrounding climate, human-influenced global warming may be partly responsible for mass loss. However, previous research studies have been limited to analyzing the past several decades, and it remains unclear whether past glacier mass losses are within the range of natural internal climate variability. Here, we apply an optimal fingerprinting technique to observed and reconstructed mass losses as well as multi-model general circulation model (GCM) simulations of mountain glacier mass to detect and attribute past glacier mass changes. An 8,800-year control simulation of glaciers enabled us to evaluate detectability. The results indicate that human-induced increases in greenhouse gases have contributed to the decreased area-weighted average masses of 85 analyzed glaciers. The effect was larger than the mass increase caused by natural forcing, although the contributions of natural and anthropogenic forcing to decreases in mass varied at the local scale. We also showed that the detection of anthropogenic or natural influences could not be fully attributed when natural internal climate variability was taken into account.

  4. Contributions of natural and anthropogenic radiative forcing to mass loss of Northern Hemisphere mountain glaciers and quantifying their uncertainties

    Science.gov (United States)

    Hirabayashi, Yukiko; Nakano, Kazunari; Zhang, Yong; Watanabe, Satoshi; Tanoue, Masahiro; Kanae, Shinjiro

    2016-07-01

    Observational evidence indicates that a number of glaciers have lost mass in the past. Given that glaciers are highly impacted by the surrounding climate, human-influenced global warming may be partly responsible for mass loss. However, previous research studies have been limited to analyzing the past several decades, and it remains unclear whether past glacier mass losses are within the range of natural internal climate variability. Here, we apply an optimal fingerprinting technique to observed and reconstructed mass losses as well as multi-model general circulation model (GCM) simulations of mountain glacier mass to detect and attribute past glacier mass changes. An 8,800-year control simulation of glaciers enabled us to evaluate detectability. The results indicate that human-induced increases in greenhouse gases have contributed to the decreased area-weighted average masses of 85 analyzed glaciers. The effect was larger than the mass increase caused by natural forcing, although the contributions of natural and anthropogenic forcing to decreases in mass varied at the local scale. We also showed that the detection of anthropogenic or natural influences could not be fully attributed when natural internal climate variability was taken into account.

  5. Neutral Particle Analyzer Diagnostic on NSTX

    International Nuclear Information System (INIS)

    Medley, S.S.; Roquemore, A.L.

    2004-01-01

    The Neutral Particle Analyzer (NPA) diagnostic on the National Spherical Torus Experiment (NSTX) utilizes a PPPL-designed E||B spectrometer that measures the energy spectra of minority hydrogen and bulk deuterium species simultaneously with 39 energy channels per mass specie and a time resolution of 1 ms. The calibrated energy range is E = 0.5-150 keV and the energy resolution varies from AE/E = 3-7% over the surface of the microchannel plate detector

  6. Neutral Particle Analyzer Diagnostic on NSTX

    Energy Technology Data Exchange (ETDEWEB)

    S.S. Medley; A.L. Roquemore

    2004-03-16

    The Neutral Particle Analyzer (NPA) diagnostic on the National Spherical Torus Experiment (NSTX) utilizes a PPPL-designed E||B spectrometer that measures the energy spectra of minority hydrogen and bulk deuterium species simultaneously with 39 energy channels per mass specie and a time resolution of 1 ms. The calibrated energy range is E = 0.5-150 keV and the energy resolution varies from AE/E = 3-7% over the surface of the microchannel plate detector.

  7. Analyzing the requirements for mass production of small wind turbine generators

    Science.gov (United States)

    Anuskiewicz, T.; Asmussen, J.; Frankenfield, O.

    Mass producibility of small wind turbine generators to give manufacturers design and cost data for profitable production operations is discussed. A 15 kW wind turbine generator for production in annual volumes from 1,000 to 50,000 units is discussed. Methodology to cost the systems effectively is explained. The process estimate sequence followed is outlined with emphasis on the process estimate sheets compiled for each component and subsystem. These data enabled analysts to develop cost breakdown profiles crucial in manufacturing decision-making. The appraisal also led to various design recommendations including replacement of aluminum towers with cost effective carbon steel towers. Extensive cost information is supplied in tables covering subassemblies, capital requirements, and levelized energy costs. The physical layout of the plant is depicted to guide manufacturers in taking advantage of the growing business opportunity now offered in conjunction with the national need for energy development.

  8. Evaluation of mass spectrometry of urinary proteins and peptides as biomarkers for cats at risk of developing azotemia.

    Science.gov (United States)

    Jepson, Rosanne E; Coulton, Gary R; Cowan, Matthew L; Markwell, Peter; Syme, Harriet M; Elliott, Jonathan

    2013-02-01

    To evaluate proteomic delineation of feline urine by mass spectrometry as a method for identifying biomarkers in cats at risk of developing azotemia. Urine samples from geriatric cats (> 9 years old) with chronic kidney disease and nonazotemic cats that either remained nonazotemic (n = 10) or developed azotemia (10) within 1 year. Optimization studies with pooled urine were performed to facilitate the use of surface enhanced laser desorption-ionization time-of-flight mass spectrometry (SELDI-TOF-MS) for analysis of the urinary proteome of cats. Urine samples from nonazotemic cats at entry to the study were analyzed via SELDI-TOF-MS with weak cation exchange and strong anion exchange arrays. Spectral data were compared to identify biomarkers for development of azotemia. Low protein concentration in feline urine precluded direct application to array surfaces, and a buffer exchange and concentration step was required prior to SELDI-TOF-MS analysis. Three preparation conditions by use of weak cation and strong anion exchange arrays were selected on the basis of optimization studies for detection of biomarkers. Eight potential biomarkers with an m/z of 2,822, 9,886, 10,033, 10,151, 10,234, 11,653, 4,421, and 9,505 were delineated. SELDI-TOF-MS can be used to detect urinary low-molecular weight peptides and proteins that may represent biomarkers for early detection of renal damage. Further study is required to purify and identify potential biomarkers before their use in a clinical setting.

  9. Mass Spectrometry Parameters Optimization for the 46 Multiclass Pesticides Determination in Strawberries with Gas Chromatography Ion-Trap Tandem Mass Spectrometry

    Science.gov (United States)

    Fernandes, Virgínia C.; Vera, Jose L.; Domingues, Valentina F.; Silva, Luís M. S.; Mateus, Nuno; Delerue-Matos, Cristina

    2012-12-01

    Multiclass analysis method was optimized in order to analyze pesticides traces by gas chromatography with ion-trap and tandem mass spectrometry (GC-MS/MS). The influence of some analytical parameters on pesticide signal response was explored. Five ion trap mass spectrometry (IT-MS) operating parameters, including isolation time (IT), excitation voltage (EV), excitation time (ET), maximum excitation energy or " q" value (q), and isolation mass window (IMW) were numerically tested in order to maximize the instrument analytical signal response. For this, multiple linear regression was used in data analysis to evaluate the influence of the five parameters on the analytical response in the ion trap mass spectrometer and to predict its response. The assessment of the five parameters based on the regression equations substantially increased the sensitivity of IT-MS/MS in the MS/MS mode. The results obtained show that for most of the pesticides, these parameters have a strong influence on both signal response and detection limit. Using the optimized method, a multiclass pesticide analysis was performed for 46 pesticides in a strawberry matrix. Levels higher than the limit established for strawberries by the European Union were found in some samples.

  10. 99mTc-HYNIC-TOC imaging in the evaluation of pancreatic masses which are potential neuroendocrine tumors.

    Science.gov (United States)

    Qiao, Zhen; Zhang, Jingjing; Jin, Xiaona; Huo, Li; Zhu, Zhaohui; Xing, Haiqun; Li, Fang

    2015-05-01

    The aim of this investigation was to determine the accuracy of the findings and the diagnoses of Tc-hydrazinonicotinyl-Tyr3-octreotide scan (Tc-HYNIC-TOC imaging) in patients with pancreatic masses which were potential neuroendocrine tumors. Records of total 20 patients with pancreatic masses were retrospectively reviewed. All of the patients had been revealed by abdominal contrast CT and possibility of neuroendocrine tumors could not be excluded by CT imaging before Tc-HYNIC-TOC imaging. Tc-HYNIC-TOC imaging was performed at 1 and 4 hours post-tracer injection, and SPECT/CT images of the abdomen were also acquired. The image findings were compared to final diagnoses which were made from pathological examination. Among all 20 pancreatic masses evaluated, there were 16 malignant lesions which included 1 ductal adenocarcinoma and 15 neuroendocrine tumors. Tc-HYNIC-TOC imaging identified 14 of 15 pancreatic neuroendocrine tumors and excluded 4 of 5 lesions which were not neuroendocrine tumors. The overall sensitivity, specificity, and accuracy was therefore 93.3% (14 of 15), 80% (4 of 5), and 90.0% (18 of 20), respectively, in our patient population. Tc-HYNIC-TOC imaging provides reasonable accuracy in the evaluation pancreatic mass suspected to be neuroendocrine tumors.

  11. Simultaneous ion detection in a mass spectrometer with variable mass dispersion

    International Nuclear Information System (INIS)

    Tuithof, H.H.

    1977-01-01

    This thesis mainly describes the ion-optics of a magnetic mass spectrometer system, especially applied to the projection of a significant part of the mass spectrum onto a flat ion-detector. The complete detector consists of a channeltron electron multiplier array with phosphor screen and a Vidicon-multichannel analyzer combination for simultaneous read-out. In order to optimise the spectral range projected onto the channelplate, by varying the mass dispersion and to rotate the oblique angle of the mass focal plane with respect to the detector surface, the sector magnet has been combined with electrostatic and magnetic quadrupole lenses. This detector will find wide application in the analysis of minute sample quantities, in the recording of extremely short ion events (large molecules) and at collision activation mass-spectrometry studies

  12. Evaluation of laser diode thermal desorption-tandem mass spectrometry (LDTD-MS-MS) in forensic toxicology.

    Science.gov (United States)

    Bynum, Nichole D; Moore, Katherine N; Grabenauer, Megan

    2014-10-01

    Many forensic laboratories experience backlogs due to increased drug-related cases. Laser diode thermal desorption (LDTD) has demonstrated its applicability in other scientific areas by providing data comparable with instrumentation, such as liquid chromatography-tandem mass spectrometry, in less time. LDTD-MS-MS was used to validate 48 compounds in drug-free human urine and blood for screening or quantitative analysis. Carryover, interference, limit of detection, limit of quantitation, matrix effect, linearity, precision and accuracy and stability were evaluated. Quantitative analysis indicated that LDTD-MS-MS produced precise and accurate results with the average overall within-run precision in urine and blood represented by a %CV forensic toxicology but before it can be successfully implemented that there are some challenges that must be addressed. Although the advantages of the LDTD system include minimal maintenance and rapid analysis (∼10 s per sample) which makes it ideal for high-throughput forensic laboratories, a major disadvantage is its inability or difficulty analyzing isomers and isobars due to the lack of chromatography without the use of high-resolution MS; therefore, it would be best implemented as a screening technique. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. CT findings of palpable neck masses in children

    International Nuclear Information System (INIS)

    Park, Chan Sup; Chung, Won Mo; Seok, Eul Hye; Suh, Chang Hae; Chung, Won Kyun

    1994-01-01

    We performed this study to assess the value of CT in the differential diagnosis of palpable neck masses in children. We retrospectively reviewed the CT scans of the palpable neck masses in 30 children. The masses were proved histopathologically and classified into cystic, solid, and inflammatory mass and their CT findings were analyzed. Twelve cases were cystic masses, 4 were solid masses, and 14 were inflammatory lesions. Cystic masses included cystic lymphangiomas (n=6), branchial cleft cysts (n=3), thyroglossal duct cysts (n=2), and ranula (n=1). Cystic lymphangiomas showed insinuating appearances into adjacent structures and 4 cases occurred in the posterior cervical space. All branchial cleft cysts were round cystic masses with smooth wall and displaced the submandibular gland anteriorly and the sternocleidomastoid muscle posteriorly. Two thyroglossal duct cysts occurred centrally adjacent to the hyoid bone and 1 ranula in the submental area. Solid masses were juvenile hemangioma, pleomorphic adenoma in submandibular gland, neurilemmoma, and fibromatosis colli. Juvenile hemangioma showed well-enhancing mass with indistinct margin and the other solid masses had well-defined margin with their characteristic location. Inflammatory lesions were abscess (n=4), deep neck infections with lymphadenopathy (n=4), submandibular gland inflammation (n=3), and tuberculous lymphadenitis (n=3) and they showed strand-like enhancement in adjacent subcutaneous tissues. Tuberculous lymphadenitis had multiple lymph node enlargement with internal low attenuation areas and showed less surrounding strand-like enhancement than suppurative lymphadenopathies. Most neck masses in infants and children were of congenital or inflammatory origin. CT is useful for the evaluation of the child presenting with a neck mass, because it can differentiate various forms of neck masses and is able to reveal the relationship of the masses to the adjacent structures with their characteristic location

  14. CT findings of palpable neck masses in children

    Energy Technology Data Exchange (ETDEWEB)

    Park, Chan Sup; Chung, Won Mo; Seok, Eul Hye; Suh, Chang Hae; Chung, Won Kyun [College of Medicine, Inha University, Incheon (Korea, Republic of)

    1994-12-15

    We performed this study to assess the value of CT in the differential diagnosis of palpable neck masses in children. We retrospectively reviewed the CT scans of the palpable neck masses in 30 children. The masses were proved histopathologically and classified into cystic, solid, and inflammatory mass and their CT findings were analyzed. Twelve cases were cystic masses, 4 were solid masses, and 14 were inflammatory lesions. Cystic masses included cystic lymphangiomas (n=6), branchial cleft cysts (n=3), thyroglossal duct cysts (n=2), and ranula (n=1). Cystic lymphangiomas showed insinuating appearances into adjacent structures and 4 cases occurred in the posterior cervical space. All branchial cleft cysts were round cystic masses with smooth wall and displaced the submandibular gland anteriorly and the sternocleidomastoid muscle posteriorly. Two thyroglossal duct cysts occurred centrally adjacent to the hyoid bone and 1 ranula in the submental area. Solid masses were juvenile hemangioma, pleomorphic adenoma in submandibular gland, neurilemmoma, and fibromatosis colli. Juvenile hemangioma showed well-enhancing mass with indistinct margin and the other solid masses had well-defined margin with their characteristic location. Inflammatory lesions were abscess (n=4), deep neck infections with lymphadenopathy (n=4), submandibular gland inflammation (n=3), and tuberculous lymphadenitis (n=3) and they showed strand-like enhancement in adjacent subcutaneous tissues. Tuberculous lymphadenitis had multiple lymph node enlargement with internal low attenuation areas and showed less surrounding strand-like enhancement than suppurative lymphadenopathies. Most neck masses in infants and children were of congenital or inflammatory origin. CT is useful for the evaluation of the child presenting with a neck mass, because it can differentiate various forms of neck masses and is able to reveal the relationship of the masses to the adjacent structures with their characteristic location.

  15. Performance of the linear ion trap Orbitrap mass analyzer for qualitative and quantitative analysis of drugs of abuse and relevant metabolites in sewage water.

    Science.gov (United States)

    Bijlsma, Lubertus; Emke, Erik; Hernández, Félix; de Voogt, Pim

    2013-03-20

    This work illustrates the potential of liquid chromatography coupled to a hybrid linear ion trap Fourier Transform Orbitrap mass spectrometer for the simultaneous identification and quantification of 24 drugs of abuse and relevant metabolites in sewage water. The developed methodology consisted of automatic solid-phase extraction using Oasis HLB cartridges, chromatographic separation of the targeted drugs, full-scan accurate mass data acquisition under positive electrospray ionization mode over an m/z range of 50-600Da at a resolution of 30,000 FWHM and simultaneous MS(n) measurements to obtain information of fragment ions generated in the linear ion trap. Accurate mass of the protonated molecule, together with at least one nominal mass product ion and retention time allowed the confident identification of the compounds detected in these complex matrices. In addition to the highly reliable qualitative analysis, Orbitrap analyzer also proved to have satisfactory potential for quantification at sub-ppb analyte levels, a possibility that has been very little explored in the literature until now. The limits of quantification ranged from 4 to 68ngL(-1) in influent sewage water, and from 2 to 35ngL(-1) in effluent, with the exception of MDA, morphine and THC that presented higher values as a consequence of the high ionization suppression in this type of samples. Satisfactory recoveries (70-120%) and precision (abuse could be identified and quantified, mainly MDMA, benzoylecgonine, codeine, oxazepam and temazepam. Orbitrap also showed potential for retrospective investigation of ketamine metabolites in the samples without the need of additional analysis. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Crashworthiness evaluation of mass transit buses.

    Science.gov (United States)

    2008-11-01

    Mass transit bus systems are an integral part of the national transportation network, serving more than 20.6 billion passenger-miles per year with a relatively low fatality rate. Bus occupant injuries are evenly distributed among crashes on all sides...

  17. Gas mass transfer for stratified flows

    International Nuclear Information System (INIS)

    Duffey, R.B.; Hughes, E.D.

    1995-01-01

    We analyzed gas absorption and release in water bodies using existing surface renewal theory. We show a new relation between turbulent momentum and mass transfer from gas to water, including the effects of waves and wave roughness, by evaluating the equilibrium integral turbulent dissipation due to energy transfer to the water from the wind. Using Kolmogoroff turbulence arguments the gas transfer velocity, or mass transfer coefficient, is then naturally and straightforwardly obtained as a non-linear function of the wind speed drag coefficient and the square root of the molecular diffusion coefficient. In dimensionless form, the theory predicts the turbulent Sherwood number to be Sh t = (2/√π)Sc 1/2 , where Sh t is based on an integral dissipation length scale in the air. The theory confirms the observed nonlinear variation of the mass transfer coefficient as a function of the wind speed; gives the correct transition with turbulence-centered models for smooth surfaces at low speeds; and predicts experimental data from both laboratory and environmental measurements within the data scatter. The differences between the available laboratory and field data measurements are due to the large differences in the drag coefficient between wind tunnels and oceans. The results also imply that the effect of direct aeration due to bubble entrainment at wave breaking is no more than a 20% increase in the mass transfer for the highest speeds. The theory has importance to mass transfer in both the geo-physical and chemical engineering literature

  18. Evaluation of Approaches to Analyzing Continuous Correlated Eye Data When Sample Size Is Small.

    Science.gov (United States)

    Huang, Jing; Huang, Jiayan; Chen, Yong; Ying, Gui-Shuang

    2018-02-01

    To evaluate the performance of commonly used statistical methods for analyzing continuous correlated eye data when sample size is small. We simulated correlated continuous data from two designs: (1) two eyes of a subject in two comparison groups; (2) two eyes of a subject in the same comparison group, under various sample size (5-50), inter-eye correlation (0-0.75) and effect size (0-0.8). Simulated data were analyzed using paired t-test, two sample t-test, Wald test and score test using the generalized estimating equations (GEE) and F-test using linear mixed effects model (LMM). We compared type I error rates and statistical powers, and demonstrated analysis approaches through analyzing two real datasets. In design 1, paired t-test and LMM perform better than GEE, with nominal type 1 error rate and higher statistical power. In design 2, no test performs uniformly well: two sample t-test (average of two eyes or a random eye) achieves better control of type I error but yields lower statistical power. In both designs, the GEE Wald test inflates type I error rate and GEE score test has lower power. When sample size is small, some commonly used statistical methods do not perform well. Paired t-test and LMM perform best when two eyes of a subject are in two different comparison groups, and t-test using the average of two eyes performs best when the two eyes are in the same comparison group. When selecting the appropriate analysis approach the study design should be considered.

  19. Critical assessment of nuclear mass models

    International Nuclear Information System (INIS)

    Moeller, P.; Nix, J.R.

    1992-01-01

    Some of the physical assumptions underlying various nuclear mass models are discussed. The ability of different mass models to predict new masses that were not taken into account when the models were formulated and their parameters determined is analyzed. The models are also compared with respect to their ability to describe nuclear-structure properties in general. The analysis suggests future directions for mass-model development

  20. Scalar quarkonium masses

    International Nuclear Information System (INIS)

    Lee, W.; Weingarten, D.

    1996-01-01

    We evaluate the valence approximation to the mass of scalar quarkonium for a range of different parameters. Our results strongly suggest that the infinite volume continuum limit of the mass of ss scalar quarkonium lies well below the mass of f J (1710). The resonance f 0 (1500) appears to the best candidate for ss scalar quarkonium. (orig.)

  1. Risk of malignancy index in the preoperative evaluation of patients with ovarian masses

    International Nuclear Information System (INIS)

    Jabeen, R.; Khan, S.A.; Naveed, S.

    2015-01-01

    Objective: To evaluate the ability of RMI in preoperative discrimination of benign from malignant ovarian mass among women presenting at Nishtar Hospital Multan Pakistan. Methodology: It was a prospective study conducted at department of obstetrics/gynae Nishtar Hospital Multan between September 2008 to August 2009. 60 patients of more than 30 years of age admitted in gynaecology department for surgical exploration of ovarian mass were included. All the women in whom ovarian malignancy had already been diagnosed and admitted for second laparotomy were excluded. Results: The median age at presentation of ovarian malignancy is 56 years. The sensitivity of RMI in our group was 82.3%,the specificity was 88.3%, positive predictive value was 73.7% and the negative predictive value was 92.6%. Receiver operating curves reveal that RMI was a better diagnostic marker than CA-125 or ultrasound score alone for the prediction of malignancy in ovarian masses. Conclusion: The risk of malignancy index has high specificity and sensitivity. It yielded a better diagnostic performance as compared to CA-125 or ultrasound score alone in differentiating benign from malignant ovarian lesions. (author)

  2. CT fluoroscopy-guided core needle biopsy of anterior mediastinal masses.

    Science.gov (United States)

    Iguchi, T; Hiraki, T; Matsui, Y; Fujiwara, H; Sakurai, J; Masaoka, Y; Uka, M; Tanaka, T; Gobara, H; Kanazawa, S

    2018-02-01

    To retrospectively evaluate the safety, diagnostic yield, and risk factors of diagnostic failure of computed tomography (CT) fluoroscopy-guided biopsies of anterior mediastinal masses. Biopsy procedures and results of anterior mediastinal masses in 71 patients (32 women/39 men; mean [±standard deviation] age, 53.8±20.0years; range, 14-88years) were analyzed. Final diagnoses were based on surgical outcomes, imaging findings, or clinical follow-up findings. The biopsy results were compared with the final diagnosis, and the biopsy procedures grouped by pathologic findings into diagnostic success and failure groups. Multiple putative risk factors for diagnostic failure were then assessed. Seventy-one biopsies (71 masses; mean size, 67.5±27.3mm; range 8.6-128.2mm) were analyzed. We identified 17 grade 1 and one grade 2 adverse events (25.4% overall) according to the National Cancer Institute Common Terminology Criteria for Adverse Events version 4.0. Sixty-nine biopsies (97.2%) provided samples fit for pathologic analysis. Diagnostic failure was found for eight (11.3%) masses; the 63 masses diagnosed successfully included thymic carcinoma (n=17), lung cancer (n=14), thymoma (n=12), malignant lymphoma (n=11), germ cell tumor (n=3), and others (n=6). Using a thinner needle (i.e., a 20-gauge needle) was the sole significant risk factor for diagnostic failure (P=0.039). CT fluoroscopy-guided biopsy of anterior mediastinal masses was safe and had a high diagnostic yield; however, using a thinner biopsy needle significantly increased the risk of a failed diagnosis. Copyright © 2017 Éditions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

  3. Development of evaluation methods for impact of earthquake-induced slope failure on nearby critical structures. Analysis of behavior of collapsed rock masses using 3-D distinct element method

    International Nuclear Information System (INIS)

    Ishimaru, Makoto; Tochigi, Hitoshi; Nakajima, Masato; Shirai, Koji

    2012-01-01

    Recently, importance of evaluation for impact of earthquake-induced slope failure on nearby critical structures is increasing in order to evaluate seismic stability of the slope, in addition to evaluating the possibilities of slope failure. In this study, we presented an examination flow chart to evaluate the impact on structures after slope failure. In the examination flow chart, we assumed the following four considerations; (1) evaluation of the collapse region of the slope, (2) evaluation of behavior of the collapsed rock masses, (3) evaluation of the impact on the structures, (4) examination of the countermeasures. And, for the purpose of using three dimensional distinct element method (DEM) for evaluation of behavior of the collapsed rock masses, we firstly confirmed applicability of DEM to behavior of a mass hurtling down the slope by means of comparing with the model test results. Moreover, we clarified influence of initial position or restitution coefficient of rock masses on final traveling distance of collapsed rock masses. (author)

  4. Symbolic Evaluation Graphs and Term Rewriting — A General Methodology for Analyzing Logic Programs

    DEFF Research Database (Denmark)

    Giesl, J.; Ströder, T.; Schneider-Kamp, P.

    2013-01-01

    There exist many powerful techniques to analyze termination and complexity of term rewrite systems (TRSs). Our goal is to use these techniques for the analysis of other programming languages as well. For instance, approaches to prove termination of definite logic programs by a transformation...... to TRSs have been studied for decades. However, a challenge is to handle languages with more complex evaluation strategies (such as Prolog, where predicates like the cut influence the control flow). We present a general methodology for the analysis of such programs. Here, the logic program is first...... information on the termination or complexity of the original logic program. More information can be found in the full paper [1]. © 2013 Springer-Verlag....

  5. Relationship between body mass index and fibromyalgia features.

    Science.gov (United States)

    Yunus, Muhammad B; Arslan, Sule; Aldag, Jean C

    2002-01-01

    to evaluate the relationship between body mass index (BMI) and features of the fibromyalgia syndrome (FMS). 211 female patients with FMS seen consecutively in our rheumatology clinic were analyzed. Spearman correlation was used. Further, FMS features were compared at different levels of BMI (kg/m2), e.g., or = 25.00 (normal vs overweight). P value of BMI and age (pBMI and education (pBMI (pBMI in FMS with a trend towards significance for fatigue and TP. Weight loss may improve physical functioning in this disorder.

  6. A model for evaluating beef cattle rations considering effects of ruminal fiber mass

    OpenAIRE

    Henrique,Douglas Sampaio; Lana,Rogério de Paula; Vieira,Ricardo Augusto Mendonça; Fontes,Carlos Augusto de Alencar; Botelho,Mosar Faria

    2011-01-01

    A mathematical model based on Cornell Net Carbohydrate and Protein System (CNCPS) was developed and adapted in order to evaluate beef cattle rations at tropical climate conditions. The presented system differs from CNCPS in the modeling of insoluble particles' digestion and passage kinetics, which enabled the estimation of fiber mass in rumen and its effects on animal performance. The equations used to estimate metabolizable protein and net energy requirements for gain, net energy requirement...

  7. Stability and Application of Reactive Nitrogen and Oxygen Species-Induced Hemoglobin Modifications in Dry Blood Spots As Analyzed by Liquid Chromatography Tandem Mass Spectrometry.

    Science.gov (United States)

    Chen, Hauh-Jyun Candy; Fan, Chih-Huang; Yang, Ya-Fen

    2016-12-19

    Dried blood spot (DBS) is an emerging microsampling technique for the bioanalysis of small molecules, including fatty acids, metabolites, drugs, and toxicants. DBS offers many advantages as a sample format including easy sample collection and cheap sample shipment. Hemoglobin adducts have been recognized as a suitable biomarker for monitoring chemical exposure. We previously reported that certain modified peptides in hemoglobin derived from reactive chlorine, nitrogen, and oxygen species are associated with factors including smoking, diabetes mellitus, and aging. However, the stability of these oxidation-induced modifications of hemoglobin remains unknown and whether they can be formed artifactually during storage of DBS. To answer these questions, globin extracted from the DBS cards was analyzed, and the stability of the modifications was evaluated. After storage of the DBS cards at 4 °C or room temperature up to 7 weeks, we isolated globin from a quarter of the spot every week. The extents of 11 sites and types of post-translational modifications (PTMs), including nitration and nitrosylation of tyrosine and oxidation of cysteine and methionine residues, in human hemoglobin were measured in the trypsin digest by nanoflow liquid chromatography-nanospray ionization tandem mass spectrometry (nanoLC-NSI/MS/MS) using selected reaction monitoring. The extents of all these PTMs are stable within 14 days when stored on DBS at room temperature and at 4 °C, while those from direct extraction of fresh blood are stable for at least 8 weeks when stored as an aqueous solution at -20 °C. Extraction of globin from a DBS card is of particular importance for hemolytic blood samples. To our knowledge, this is the first report on the stability of oxidative modifications of hemoglobin on DBSs, which are stable for 14 days under ambient conditions (room temperature, in air). Therefore, it is feasible and convenient to analyze these hemoglobin modifications from DBSs in studies

  8. Endoscopic ultrasound elastography for evaluation of lymph nodes and pancreatic masses: a multicenter study.

    Science.gov (United States)

    Giovannini, Marc; Thomas, Botelberge; Erwan, Bories; Christian, Pesenti; Fabrice, Caillol; Benjamin, Esterni; Geneviève, Monges; Paolo, Arcidiacono; Pierre, Deprez; Robert, Yeung; Walter, Schimdt; Hanz, Schrader; Carl, Szymanski; Christoph, Dietrich; Pierre, Eisendrath; Jean-Luc, Van Laethem; Jacques, Devière; Peter, Vilmann; Andrian, Saftoiu

    2009-04-07

    To evaluate the ability of endoscopic ultrasound (EUS) elastography to distinguish benign from malignant pancreatic masses and lymph nodes. A multicenter study was conducted and included 222 patients who underwent EUS examination with assessment of a pancreatic mass (n = 121) or lymph node (n = 101). The classification as benign or malignant, based on the real time elastography pattern, was compared with the classification based on the B-mode EUS images and with the final diagnosis obtained by EUS-guided fine needle aspiration (EUS-FNA) and/or by surgical pathology. An interobserver study was performed. The sensitivity and specificity of EUS elastography to differentiate benign from malignant pancreatic lesions are 92.3% and 80.0%, respectively, compared to 92.3% and 68.9%, respectively, for the conventional B-mode images. The sensitivity and specificity of EUS elastography to differentiate benign from malignant lymph nodes was 91.8% and 82.5%, respectively, compared to 78.6% and 50.0%, respectively, for the B-mode images. The kappa coefficient was 0.785 for the pancreatic masses and 0.657 for the lymph nodes. EUS elastography is superior compared to conventional B-mode imaging and appears to be able to distinguish benign from malignant pancreatic masses and lymph nodes with a high sensitivity, specificity and accuracy. It might be reserved as a second line examination to help characterise pancreatic masses after negative EUS-FNA and might increase the yield of EUS-FNA for lymph nodes.

  9. Modified quadrupole mass analyzer RGA-100 for beam plasma research in forevacuum pressure range

    Energy Technology Data Exchange (ETDEWEB)

    Zolotukhin, D. B.; Tyunkov, A. V. [Tomsk State University of Control Systems and Radioelectronics, 40 Lenin Ave., Tomsk 634050 (Russian Federation); Yushkov, Yu. G., E-mail: yuyushkov@gmail.com [Tomsk State University of Control Systems and Radioelectronics, 40 Lenin Ave., Tomsk 634050 (Russian Federation); Tomsk Polytechnic University, 30 Lenin Ave., Tomsk 634050 (Russian Federation); Oks, E. M. [Tomsk State University of Control Systems and Radioelectronics, 40 Lenin Ave., Tomsk 634050 (Russian Federation); Institute of High Current Electronics SB RAS, 2/3, Akademichesky Ave., Tomsk 634055 (Russian Federation)

    2015-12-15

    The industrial quadrupole RGA-100 residual gas analyzer was modified for the research of electron beam-generated plasma at forevacuum pressure range. The standard ionizer of the RGA-100 was replaced by three electrode extracting unit. We made the optimization of operation parameters in order to provide the maximum values of measured currents of any ion species. The modified analyzer was successfully tested with beam plasma of argon, nitrogen, oxygen, and hydrocarbons.

  10. A new qualitative pattern classification of shear wave elastograghy for solid breast mass evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Cong, Rui, E-mail: congrui2684@163.com; Li, Jing, E-mail: lijing@sj-hospital.org; Guo, Song, E-mail: 21751735@qq.com

    2017-02-15

    Highlights: • Qualitative SWE classification proposed here was significantly better than quantitative SWE parameters. • Qualitative classification proposed here was better than the classification proposed before. • Qualitative classification proposed here could obtain higher specificity without a loss of sensitivity. - Abstract: Objectives: To examine the efficacy of qualitative shear wave elastography (SWE) in the classification and evaluation of solid breast masses, and to compare this method with conventional ultrasonograghy (US), quantitative SWE parameters and qualitative SWE classification proposed before. Methods: From April 2015 to March 2016, 314 consecutive females with 325 breast masses who decided to undergo core needle biopsy and/or surgical biopsy were enrolled. Conventional US and SWE were previously performed in all enrolled subjects. Each mass was classified by two different qualitative classifications. One was established in our study, herein named the Qual1. Qual1 could classify the SWE images into five color patterns by the visual evaluations: Color pattern 1 (homogeneous pattern); Color pattern 2 (comparative homogeneous pattern); Color pattern 3 (irregularly heterogeneous pattern); Color pattern 4 (intralesional echo pattern); and Color pattern 5 (the stiff rim sign pattern). The second qualitative classification was named Qual2 here, and included a four-color overlay pattern classification (Tozaki and Fukuma, Acta Radiologica, 2011). The Breast Imaging Reporting and Data System (BI-RADS) assessment and quantitative SWE parameters were recorded. Diagnostic performances of conventional US, SWE parameters, and combinations of US and SWE parameters were compared. Results: With pathological results as the gold standard, of the 325 examined breast masses, 139 (42.77%) samples were malignant and 186 (57.23%) were benign. The Qual1 showed a higher Az value than the Qual2 and quantitative SWE parameters (all P < 0.05). When applying Qual1

  11. A new qualitative pattern classification of shear wave elastograghy for solid breast mass evaluation

    International Nuclear Information System (INIS)

    Cong, Rui; Li, Jing; Guo, Song

    2017-01-01

    Highlights: • Qualitative SWE classification proposed here was significantly better than quantitative SWE parameters. • Qualitative classification proposed here was better than the classification proposed before. • Qualitative classification proposed here could obtain higher specificity without a loss of sensitivity. - Abstract: Objectives: To examine the efficacy of qualitative shear wave elastography (SWE) in the classification and evaluation of solid breast masses, and to compare this method with conventional ultrasonograghy (US), quantitative SWE parameters and qualitative SWE classification proposed before. Methods: From April 2015 to March 2016, 314 consecutive females with 325 breast masses who decided to undergo core needle biopsy and/or surgical biopsy were enrolled. Conventional US and SWE were previously performed in all enrolled subjects. Each mass was classified by two different qualitative classifications. One was established in our study, herein named the Qual1. Qual1 could classify the SWE images into five color patterns by the visual evaluations: Color pattern 1 (homogeneous pattern); Color pattern 2 (comparative homogeneous pattern); Color pattern 3 (irregularly heterogeneous pattern); Color pattern 4 (intralesional echo pattern); and Color pattern 5 (the stiff rim sign pattern). The second qualitative classification was named Qual2 here, and included a four-color overlay pattern classification (Tozaki and Fukuma, Acta Radiologica, 2011). The Breast Imaging Reporting and Data System (BI-RADS) assessment and quantitative SWE parameters were recorded. Diagnostic performances of conventional US, SWE parameters, and combinations of US and SWE parameters were compared. Results: With pathological results as the gold standard, of the 325 examined breast masses, 139 (42.77%) samples were malignant and 186 (57.23%) were benign. The Qual1 showed a higher Az value than the Qual2 and quantitative SWE parameters (all P < 0.05). When applying Qual1

  12. Comparison and clinical utility evaluation of four multiple allergen simultaneous tests including two newly introduced fully automated analyzers

    Directory of Open Access Journals (Sweden)

    John Hoon Rim

    2016-04-01

    Full Text Available Background: We compared the diagnostic performances of two newly introduced fully automated multiple allergen simultaneous tests (MAST analyzers with two conventional MAST assays. Methods: The serum samples from a total of 53 and 104 patients were tested for food panels and inhalant panels, respectively, in four analyzers including AdvanSure AlloScreen (LG Life Science, Korea, AdvanSure Allostation Smart II (LG Life Science, PROTIA Allergy-Q (ProteomeTech, Korea, and RIDA Allergy Screen (R-Biopharm, Germany. We compared not only the total agreement percentages but also positive propensities among four analyzers. Results: Evaluation of AdvanSure Allostation Smart II as upgraded version of AdvanSure AlloScreen revealed good concordance with total agreement percentages of 93.0% and 92.2% in food and inhalant panel, respectively. Comparisons of AdvanSure Allostation Smart II or PROTIA Allergy-Q with RIDA Allergy Screen also showed good concordance performance with positive propensities of two new analyzers for common allergens (Dermatophagoides farina and Dermatophagoides pteronyssinus. The changes of cut-off level resulted in various total agreement percentage fluctuations among allergens by different analyzers, although current cut-off level of class 2 appeared to be generally suitable. Conclusions: AdvanSure Allostation Smart II and PROTIA Allergy-Q presented favorable agreement performances with RIDA Allergy Screen, although positive propensities were noticed in common allergens. Keywords: Multiple allergen simultaneous test, Automated analyzer

  13. Rapid screening of pharmaceutical drugs using thermal desorption – SALDI mass spectrometry

    International Nuclear Information System (INIS)

    Grechnikov, A A; Kubasov, A E; Borodkov, A S; Georgieva, V B; Nikiforov, S M; Simanovsky, Ya O; Alimpiev, S S

    2012-01-01

    A novel approach to the rapid screening of pharmaceutical drugs by surface assisted laser desorption-ionization (SALDI) mass spectrometry with the rotating ball interface coupled with temperature programmed thermal desorption has been developed. Analytes were thermally desorbed and deposited onto the surface of amorphous silicon substrate attached to the rotating ball. The ball was rotated and the deposited analytes were analyzed using SALDI. The effectiveness of coupling SALDI mass spectrometry with thermal desorption was evaluated by the direct and rapid analysis of tablets containing lidocaine, diphenhydramine and propranolol without any sample pretreatment. The overall duration of the screening procedure was 30÷40 sec. Real urine samples were studied for drug analysis. It is shown that with simple preparation steps, urine samples can be quantitatively analyzed using the proposed technique with the detection limits in the range of 0.2÷0.5 ng/ml.

  14. Application of the mass-spectrometer MASHA for mass-spectrometry and laser-spectroscopy

    Science.gov (United States)

    Rodin, A. M.; Belozerov, A. V.; Dmitriev, S. N.; Oganessian, Yu. Ts.; Sagaidak, R. N.; Salamatin, V. S.; Stepantsov, S. V.; Vanin, D. V.

    2010-02-01

    We report the present status of the mass-spectrometer MASHA (Mass-Analyzer of Supper Heavy Atoms) designed for determination of the masses of superheavy elements. The mass-spectrometer is connected to the U-400M cyclotron of the Flerov Laboratory for Nuclear Reactions (FLNR) JINR, Dubna. The first experiments on mass-measurements for 112 and 114 elements will be performed in the upcoming 2010. For this purpose a hot catcher, based on a graphite stopper, is constructed. The α-decay of the superheavy nuclides or spontaneous fission products will be detected with a silicon 192 strips detector. The experimental program of future investigations using the technique of a gas catcher is discussed. It should be regarded as an alternative of the classical ISOL technique. The possibilities are considered for using this mass-spectrometer for laser spectroscopy of nuclei far off-stability.

  15. Application of the mass-spectrometer MASHA for mass-spectrometry and laser-spectroscopy

    International Nuclear Information System (INIS)

    Rodin, A. M.; Belozerov, A. V.; Dmitriev, S. N.; Oganessian, Yu. Ts.; Sagaidak, R. N.; Salamatin, V. S.; Stepantsov, S. V.; Vanin, D. V.

    2010-01-01

    We report the present status of the mass-spectrometer MASHA (Mass-Analyzer of Supper Heavy Atoms) designed for determination of the masses of superheavy elements. The mass-spectrometer is connected to the U-400M cyclotron of the Flerov Laboratory for Nuclear Reactions (FLNR) JINR, Dubna. The first experiments on mass-measurements for 112 and 114 elements will be performed in the upcoming 2010. For this purpose a hot catcher, based on a graphite stopper, is constructed. The α-decay of the superheavy nuclides or spontaneous fission products will be detected with a silicon 192 strips detector. The experimental program of future investigations using the technique of a gas catcher is discussed. It should be regarded as an alternative of the classical ISOL technique. The possibilities are considered for using this mass-spectrometer for laser spectroscopy of nuclei far off-stability.

  16. Application of the mass-spectrometer MASHA for mass-spectrometry and laser-spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Rodin, A. M., E-mail: rodin@nrmail.jinr.ru; Belozerov, A. V.; Dmitriev, S. N.; Oganessian, Yu. Ts.; Sagaidak, R. N.; Salamatin, V. S.; Stepantsov, S. V.; Vanin, D. V. [JINR, Flerov Laboratory of Nuclear Reactions (Russian Federation)

    2010-02-15

    We report the present status of the mass-spectrometer MASHA (Mass-Analyzer of Supper Heavy Atoms) designed for determination of the masses of superheavy elements. The mass-spectrometer is connected to the U-400M cyclotron of the Flerov Laboratory for Nuclear Reactions (FLNR) JINR, Dubna. The first experiments on mass-measurements for 112 and 114 elements will be performed in the upcoming 2010. For this purpose a hot catcher, based on a graphite stopper, is constructed. The {alpha}-decay of the superheavy nuclides or spontaneous fission products will be detected with a silicon 192 strips detector. The experimental program of future investigations using the technique of a gas catcher is discussed. It should be regarded as an alternative of the classical ISOL technique. The possibilities are considered for using this mass-spectrometer for laser spectroscopy of nuclei far off-stability.

  17. An analysis of nuclear fuel burnup in the AGR-1 TRISO fuel experiment using gamma spectrometry, mass spectrometry, and computational simulation techniques

    International Nuclear Information System (INIS)

    Harp, Jason M.; Demkowicz, Paul A.; Winston, Philip L.; Sterbentz, James W.

    2014-01-01

    Highlights: • The burnup of irradiated AGR-1 TRISO fuel was analyzed using gamma spectrometry. • The burnup of irradiated AGR-1 TRISO fuel was also analyzed using mass spectrometry. • Agreement between experimental results and neutron physics simulations was excellent. - Abstract: AGR-1 was the first in a series of experiments designed to test US TRISO fuel under high temperature gas-cooled reactor irradiation conditions. This experiment was irradiated in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) and is currently undergoing post-irradiation examination (PIE) at INL and Oak Ridge National Laboratory. One component of the AGR-1 PIE is the experimental evaluation of the burnup of the fuel by two separate techniques. Gamma spectrometry was used to non-destructively evaluate the burnup of all 72 of the TRISO fuel compacts that comprised the AGR-1 experiment. Two methods for evaluating burnup by gamma spectrometry were developed, one based on the Cs-137 activity and the other based on the ratio of Cs-134 and Cs-137 activities. Burnup values determined from both methods compared well with the values predicted from simulations. The highest measured burnup was 20.1% FIMA (fissions per initial heavy metal atom) for the direct method and 20.0% FIMA for the ratio method (compared to 19.56% FIMA from simulations). An advantage of the ratio method is that the burnup of the cylindrical fuel compacts can be determined in small (2.5 mm) axial increments and an axial burnup profile can be produced. Destructive chemical analysis by inductively coupled mass spectrometry (ICP-MS) was then performed on selected compacts that were representative of the expected range of fuel burnups in the experiment to compare with the burnup values determined by gamma spectrometry. The compacts analyzed by mass spectrometry had a burnup range of 19.3% FIMA to 10.7% FIMA. The mass spectrometry evaluation of burnup for the four compacts agreed well with the gamma

  18. Evaluation of MALDI-TOF mass spectrometry for the competitiveness analysis of selected indigenous cowpea (Vigna unguiculata L. Walp.) Bradyrhizobium strains from Kenya.

    Science.gov (United States)

    Ndungu, Samuel Mathu; Messmer, Monika M; Ziegler, Dominik; Thuita, Moses; Vanlauwe, Bernard; Frossard, Emmanuel; Thonar, Cécile

    2018-06-01

    Cowpea N 2 fixation and yield can be enhanced by selecting competitive and efficient indigenous rhizobia. Strains from contrasting agro-ecologies of Kilifi and Mbeere (Kenya) were screened. Two pot experiments were established consisting of 13 Bradyrhizobium strains; experiment 1 (11 Mbeere + CBA + BK1 from Burkina Faso), experiment 2 (12 Kilifi + CBA). Symbiotic effectiveness was assessed (shoot biomass, SPAD index and N uptake). Nodule occupancy of 13 simultaneously co-inoculated strains in each experiment was analyzed by matrix-assisted laser desorption/ionization time of flight (MALDI-TOF) mass spectrometry (MS) to assess competitiveness. Strains varied in effectiveness and competitiveness. The four most efficient strains were further evaluated in a field trial in Mbeere during the 2014 short rains. Strains from bacteroids of cowpea nodules from pot and field experiments were accurately identified as Bradyrhizobium by MALDI-TOF based on the SARAMIS™ database. In the field, abundant indigenous populations 7.10 × 10 3 rhizobia g -1 soil, outcompeted introduced strains. As revealed by MALDI-TOF, indigenous strains clustered into six distinct groups (I, II, III, IV, V and VI), group III were most abundant occupying 80% of nodules analyzed. MALDI-TOF was rapid, affordable and reliable to identify Bradyrhizobium strains directly from nodule suspensions in competition pot assays and in the field with abundant indigenous strains thus, its suitability for future competition assays. Evaluating strain competitiveness and then symbiotic efficacy is proposed in bioprospecting for potential cowpea inoculant strains.

  19. Analyzing mass perceptions of nuclear politics: Puzzling over trust

    International Nuclear Information System (INIS)

    Jenkins-Smith, H.C.; Pratt, D.A.; Bassett, G.W. Jr.

    1994-01-01

    The juxtaposition of public values, trust, and beliefs is at the core of policy-making in democratic political systems, and an accurate understanding of nuclear politics requires that researchers untangle and carefully think about the web of psychological and social influences that shape citizens' preferences. In this paper, we offer some tentative answers about several pieces of the trust open-quotes puzzleclose quotes. First, we reconsider what is meant by open-quotes trustclose quotes and how it is to be measured. We then use telephone survey data to explore the relationship between trust and citizens' nuclear policy preferences. The data lend support to the conclusion that trust is more mutable than previous research has shown, and besides the traditional measure of competence includes aspects of believability and fiduciary competence. The data further indicate that it is a mistake to think in terms of a single open-quotes publicclose quotes when exploring the link between trust and nuclear policies. A number of dissimilar open-quotes publicsclose quotes based on shared open-quotes worldviewsclose quotes or political cultures are apparent in the data analyzed here. These open-quotes publicsclose quotes appear to think about trust differently from one another and rely on different dimensions of trust when determining nuclear policy preferences. Policy-makers must recognize the different open-quotes publicsclose quotes coexisting within the U.S. nuclear policy arena, and the relative import that these publics place on different dimensions of trust

  20. Evaluating Greenland glacial isostatic adjustment corrections using GRACE, altimetry and surface mass balance data

    International Nuclear Information System (INIS)

    Sutterley, Tyler C; Velicogna, Isabella; Csatho, Beata; Rezvan-Behbahani, Soroush; Babonis, Greg; Van den Broeke, Michiel

    2014-01-01

    Glacial isostatic adjustment (GIA) represents a source of uncertainty for ice sheet mass balance estimates from the Gravity Recovery and Climate Experiment (GRACE) time-variable gravity measurements. We evaluate Greenland GIA corrections from Simpson et al (2009 Quat. Sci. Rev. 28 1631–57), A et al (2013 Geophys. J. Int. 192 557–72) and Wu et al (2010 Nature Geosci. 3 642–6) by comparing the spatial patterns of GRACE-derived ice mass trends calculated using the three corrections with volume changes from ICESat (Ice, Cloud, and land Elevation Satellite) and OIB (Operation IceBridge) altimetry missions, and surface mass balance products from the Regional Atmospheric Climate Model (RACMO). During the period September 2003–August 2011, GRACE ice mass changes obtained using the Simpson et al (2009 Quat. Sci. Rev. 28 1631–57) and A et al (2013 Geophys. J. Int. 192 557–72) GIA corrections yield similar spatial patterns and amplitudes, and are consistent with altimetry observations and surface mass balance data. The two GRACE estimates agree within 2% on average over the entire ice sheet, and better than 15% in four subdivisions of Greenland. The third GRACE estimate corrected using the (Wu et al 2010 Nature Geosci. 3 642–6)) GIA shows similar spatial patterns, but produces an average ice mass loss for the entire ice sheet that is 64 − 67 Gt yr −1 smaller. In the Northeast the recovered ice mass change is 46–49 Gt yr −1 (245–270%) more positive than that deduced from the other two corrections. By comparing the spatial and temporal variability of the GRACE estimates with trends of volume changes from altimetry and surface mass balance from RACMO, we show that the Wu et al (2010 Nature Geosci. 3 642–6) correction leads to a large mass increase in the Northeast that is inconsistent with independent observations. (paper)

  1. Critical and subcritical mass calculations of fissionable nuclides based on JENDL-3.2+

    International Nuclear Information System (INIS)

    Okuno, H.

    2002-01-01

    We calculated critical and subcritical masses of 10 fissionable actinides ( 233 U, 235 U, 238 Pu, 239 Pu, 241 Pu, 242m Am, 243 Cm, 244 Cm, 249 Cf and 251 Cf) in metal and in metal-water mixtures (except 238 Pu and 244 Cm). The calculation was made with a combination of a continuous energy Monte Carlo neutron transport code, MCNP-4B2, and the latest released version of the Japanese Evaluated Nuclear Data Library, JENDL-3.2. Other evaluated nuclear data files, ENDF/B-VI, JEF-2.2, and JENDL-3.3 in its preliminary version were also applied to find differences in results originated from different nuclear data files. For the so-called big three fissiles ( 233 U, 235 U and 239 Pu), analyzing the criticality experiments cited in ICSBEP Handbook validated the code-library combination, and calculation errors were consequently evaluated. Estimated critical and lower limit critical masses of the big three in a sphere with/without a water or SS-304 reflector were supplied, and they were compared with the subcritical mass limits of ANS-8.1. (author)

  2. Stagnation in body mass index in Denmark from 1997/1998 to 2004/2005, but with geographical diversity

    DEFF Research Database (Denmark)

    Svendstrup, Mathilde; Knudsen, Nils Jacob; Jørgensen, Torben

    2011-01-01

    INTRODUCTION: We analyzed the trend in body mass index (BMI) as well as in the prevalence of overweight and obesity among Danish adults, mainly women, from 1997/1998 to 2004/2005 and evaluated any regional differences. MATERIAL AND METHODS: Data were drawn from two cross-sectional population...

  3. Effects of mechanical massage, manual lymphatic drainage and connective tissue manipulation techniques on fat mass in women with cellulite.

    Science.gov (United States)

    Bayrakci Tunay, V; Akbayrak, T; Bakar, Y; Kayihan, H; Ergun, N

    2010-02-01

    To evaluate and compare the effectiveness of three different noninvasive treatment techniques on fat mass and regional fat thickness of the patients with cellulites. Sixty subjects were randomized into three groups. Group 1 (n = 20) treated with mechanical massage (MM), group 2 (n = 20) treated with manual lymphatic drainage (MLD) and group 3 (n = 20) treated with connective tissue manipulation (CTM) techniques. Subjects were evaluated by using standardized photographs, body composition analyzer (TBF 300) (body weight (BW), body mass index (BMI), fat %, fat mass (FM), fat free mass (FFM), total body water (TBW)), circumference measurement from thigh, waist-hip ratio (WHR), fat thickness measurements from abdomen, suprailium and thigh regions with skin fold caliper. All groups had an improvement in thinning of the subcutaneous fat after the treatment (P techniques are effective in decreasing the regional fat values of the patients with cellulites.

  4. Turkey's response to threats of weapons of mass destruction

    OpenAIRE

    Al, Guray.

    2001-01-01

    Unlike most of its NATO allies, Turkey did not emerge from the Cold War with enhanced security. The acquisition of weapons of mass destruction (WMD) and ballistic missiles by its neighbors in the Middle Eastâ Iran, Iraq and Syriaâ creates a serious security concern for Turkey. This thesis analyzes the numerous threats posed to Turkey by its neighborsα nuclear, chemical and biological weapons programs and their ballistic missiles. It evaluates Turkeyαs defense options to counter these thre...

  5. Proposal of rock mass behavior classification based on convergence measurement in shaft sinking through sedimentary soft rocks

    International Nuclear Information System (INIS)

    Tsusaka, Kimikazu

    2010-01-01

    Japan Atomic Energy Agency has been excavating deep shafts through sedimentary soft rocks in Horonobe, Hokkaido. From the viewpoint of the observational construction, site engineers need a practical guide to evaluate the field measurements conducted with shaft sinking. The author analyzed the relationship among initial deformation rate, observed deformation, the ratio of the modulus of elasticity of rock mass to the initial stress, and the magnitude of inelastic behavior of rock based on convergence measurements and investigation of rock mass properties on shaft walls. As a result, the rock mass behavior classification for shaft sinking which consists of three classes was proposed. (author)

  6. CT evaluation of mass lesions in the parotid region

    International Nuclear Information System (INIS)

    Matsumoto, Shunichi; Kishikawa, Takashi; Kudo, Sho; Miyaji, Hiroshi; Kuwano, Haruo; Kaneko, Kuniyuki; Ohuchida, Toshiyuki

    1988-01-01

    CT findings of 35 patients with proven 31 parotid gland mass lesions (23 benign tumors, 5 malignant tumors, 3 inflammatory diseases) and 4 infraauricular lymphadenopathy (2 inflammatory nodes, 2 neoplastic nodes) were reviewed. CT accurately diagnosed the parotid origin in 29 of 31 parotid gland diseases. In all four patients with infraauricular lymphadenopathy, differentiation from parotid tumor was difficult. CT differentiation between superficial and deep lobe tumors agreed with surgical findings in 18 of 21 parotid gland tumors. Twenty out of 23 benign parotid gland tumors appeared as discrete masses with smooth margins. All five malignant parotid gland tumors appeared as poorly defined masses. It is concluded that when a tumor is located in the superficial lobe and appears as a sharply circumscribed mass on plain CT, it should be diagnosed as a benign lesion and contrast CT is not required. Secondly, contrast CT would be beneficial when a tumor is indistinct, or located in the deep portion of the parotid gland on plain CT. Finally, CT-sialography is considered unnecessary in the diagnosis of parotid masses. (author)

  7. High-throughput simultaneous determination of plasma water deuterium and 18-oxygen enrichment using a high-temperature conversion elemental analyzer with isotope ratio mass spectrometry.

    Science.gov (United States)

    Richelle, M; Darimont, C; Piguet-Welsch, C; Fay, L B

    2004-01-01

    This paper presents a high-throughput method for the simultaneous determination of deuterium and oxygen-18 (18O) enrichment of water samples isolated from blood. This analytical method enables rapid and simple determination of these enrichments of microgram quantities of water. Water is converted into hydrogen and carbon monoxide gases by the use of a high-temperature conversion elemental analyzer (TC-EA), that are then transferred on-line into the isotope ratio mass spectrometer. Accuracy determined with the standard light Antartic precipitation (SLAP) and Greenland ice sheet precipitation (GISP) is reliable for deuterium and 18O enrichments. The range of linearity is from 0 up to 0.09 atom percent excess (APE, i.e. -78 up to 5725 delta per mil (dpm)) for deuterium enrichment and from 0 up to 0.17 APE (-11 up to 890 dpm) for 18O enrichment. Memory effects do exist but can be avoided by analyzing the biological samples in quintuplet. This method allows the determination of 1440 samples per week, i.e. 288 biological samples per week. Copyright 2004 John Wiley & Sons, Ltd.

  8. Evaluation of high-resolution mass spectrometry for urine toxicology screening in a pain management setting.

    Science.gov (United States)

    Crews, Bridgit O; Pesce, Amadeo J; West, Robert; Nguyen, Hugh; Fitzgerald, Robert L

    2012-01-01

    To evaluate liquid chromatography-high-resolution mass spectrometry (LC-HR-MS) for urine toxicology screening, 29 analytes were quantitated in 152 urine specimens from patients with chronic pain using two unique mass spectrometry platforms. De-identified specimens were quantitated in April of 2011 by liquid chromatography-triple quadrupole mass spectrometry (LC-MS-MS) and by full-scan LC-HR-MS at Millennium Laboratories. Considering LC-MS-MS as the reference method, false positive results were identified in 19 specimens measured by LC-HR-MS. Application of relative retention times using deuterium labeled internal standards improved the rate of false positive detection to only five specimens, with four occurring for the same analyte. Ultra-high-resolution mass spectrometry (R = 100,000 at m/z 200) showed no improvement over high-resolution mass spectrometry (R = 10,000 at m/z 200) in the number of false positives detected. Quantitative results measured by LC-MS-MS and LC-HR-MS showed good agreement over four orders of dynamic range. This study demonstrates that LC-HR-MS is a suitable platform for toxicology screening for a pain management population and that quantitative accuracy and sensitivity are comparable to that achieved with LC-MS-MS. The specificity of LC-HR-MS is improved by the addition of deuterium labeled internal standards and the implementation of relative retention time matching.

  9. Evaluation of ECG-gated [(11)C]acetate PET for measuring left ventricular volumes, mass, and myocardial external efficiency.

    Science.gov (United States)

    Hansson, Nils Henrik; Tolbod, Lars; Harms, Johannes; Wiggers, Henrik; Kim, Won Yong; Hansen, Esben; Zaremba, Tomas; Frøkiær, Jørgen; Jakobsen, Steen; Sørensen, Jens

    2016-08-01

    Noninvasive estimation of myocardial external efficiency (MEE) requires measurements of left ventricular (LV) oxygen consumption with [(11)C]acetate PET in addition to LV stroke volume and mass with cardiovascular magnetic resonance (CMR). Measuring LV geometry directly from ECG-gated [(11)C]acetate PET might enable MEE evaluation from a single PET scan. Therefore, we sought to establish the accuracy of measuring LV volumes, mass, and MEE directly from ECG-gated [(11)C]acetate PET. Thirty-five subjects with aortic valve stenosis underwent ECG-gated [(11)C]acetate PET and CMR. List mode PET data were rebinned into 16-bin ECG-gated uptake images before measuring LV volumes and mass using commercial software and compared to CMR. Dynamic datasets were used for calculation of mean LV oxygen consumption and MEE. LV mass, volumes, and ejection fraction measured by CMR and PET correlated strongly (r = 0.86-0.92, P PET (P PET-based MEE, corrected for bias, correlated fairly with PET/CMR-based MEE (r = 0.60, P PET-based MEE bias was strongly associated with LV wall thickness. Although analysis-related improvements in accuracy are recommended, LV geometry estimated from ECG-gated [(11)C]acetate PET correlate excellently with CMR and can indeed be used to evaluate MEE.

  10. Usefulness of enteral contrast media in MR evaluation of pelvic mass

    International Nuclear Information System (INIS)

    Kim, Hun; Kim, Jung Sik; Kim, Hong; Shon, Chul Ho; Lee, Hee Jung; Lee, Sung Moon; Woo, Sung Ku; Suh, Soo Jhi

    1999-01-01

    To assess the value of enteral contrast media for the evaluation of pelvic masses by MR imaging. Between April and July 1998, 16 women with pelvic masses were examined by MRI. The origin of the lesion was the ovary in twelve cases, the uterus in three, and the sigmoid in one. Using a 1.5T scanner(Magnetom Vision, Siemens), T1-weighted axial spin echo(SE), T2-weighted turbo spin echo(TSE), two dimensional fast low-angle shot(FLASH 2D), and half-Fourier TSE(HASTE) images were obtained in all patients after the administration of Magnevist Enteral (Shering, Berlin, Germany). In each MR imagine sequence, distinction between the lesion and adjacent bowel (1, not distinguished; 2, partly distinguished; 3, clearly distinguished), artifact (0, absent; 1, mild; 2, severe), image quality (1, poor; 2, fair; 3, good), were compared before and after the use of enteral contrast media. Changes in MRI impression after the use of enteral contrast media were also evaluated. Two radiologists reached a consensus after reviewing the images. Statistical significance was determined by Wilcoxon's signed ranked test. For distinguishing lesions, SE T1WI and FLASH 2D with enteral contrast media were significantly superior to SE T1WI without enteral contrast media (p < 0.05). With regard to image quality, FLASH 2D and HASTE, both with enteral contrast media, were significantly superior to SE T1WI and TSE T2WI, respectively, both without enteral contrast media (p < 0.05). Artefacts were more frequently found after the application of enteral contrast media in conventional sequences but were not present in breathhold sequences. In two patients, MRI impression changed after the application of enteral contrast media. In a limited number of cases, enteral contrast media improved lesion detection, image quality and diagnostic accuracy when breathhold fast MR imaging was applied

  11. CT and MRT in mediastinal and hilar masses. CT und MRT bei mediastinalen und hilaeren Raumforderungen

    Energy Technology Data Exchange (ETDEWEB)

    Prayer, L.; Kramer, J.; Stiglbauer, R.; Wimberger, D.; Imhof, H. (Vienna Univ. (Austria). Klinik fuer Radiodiagnostik Ludwig-Boltzmann-Institut fuer Radiologisch-Physikalische Tumordiagnostik, Vienna (Austria)); Metz, V. (Vienna Univ. (Austria). 2. Chirurgische Klinik)

    1990-11-01

    Thirty-eight patients with mediastinal and/or hilar masses were imaged by computed tomography (CT) and magnetic resonance imaging (MRI). Results were analyzed retrospectively regarding the ability to demonstrate the masses, their number, size, definition, location and tissue characteristics. CT and MRI showed equivalent results in 32 cases; additional information was obtained in two patients by CT, in four patients by MRI. In view of the specific advantages and limitations of both CT and MRI we believed that in patients with mediastinal and/or hilar masses, contrast enhanced CT remains the procedure of choice after performing plain chest radiographs; in certain cases MRI will prove useful for further evaluation. (orig.).

  12. Mass spectrometry-assisted protease substrate screening

    DEFF Research Database (Denmark)

    Schlüter, Hartmut; Rykl, Jana; Thiemann, Joachim

    2007-01-01

    -phase chromatography they are analyzed by tandem mass spectrometry and the substrates identified by database searching. The proof of principle in this study is demonstrated by incubating immobilized human plasma proteins with thrombin and by identifying by tandem mass spectrometry the fibrinopeptides, released...

  13. Diagnostic performance of quantitative shear wave elastography in the evaluation of solid breast masses: determination of the most discriminatory parameter.

    Science.gov (United States)

    Au, Frederick Wing-Fai; Ghai, Sandeep; Moshonov, Hadas; Kahn, Harriette; Brennan, Cressida; Dua, Hemi; Crystal, Pavel

    2014-09-01

    The purpose of this article is to assess the diagnostic performance of quantitative shear wave elastography in the evaluation of solid breast masses and to determine the most discriminatory parameter. B-mode ultrasound and shear wave elastography were performed before core biopsy of 123 masses in 112 women. The diagnostic performance of ultrasound and quantitative shear wave elastography parameters (mean elasticity, maximum elasticity, and elasticity ratio) were compared. The added effect of shear wave elastography on the performance of ultrasound was determined. The mean elasticity, maximum elasticity, and elasticity ratio were 24.8 kPa, 30.3 kPa, and 1.90, respectively, for 79 benign masses and 130.7 kPa, 154.9 kPa, and 11.52, respectively, for 44 malignant masses (p shear wave elastography parameter was higher than that of ultrasound (p shear wave elastography parameters to the evaluation of BI-RADS category 4a masses, about 90% of masses could be downgraded to BI-RADS category 3. The numbers of downgraded masses were 40 of 44 (91%) for mean elasticity, 39 of 44 (89%) for maximum elasticity, and 42 of 44 (95%) for elasticity ratio. The numbers of correctly downgraded masses were 39 of 40 (98%) for mean elasticity, 38 of 39 (97%) for maximum elasticity, and 41 of 42 (98%) for elasticity ratio. There was improvement in the diagnostic performance of ultrasound of mass assessment with shear wave elastography parameters added to BI-RADS category 4a masses compared with ultrasound alone. Combined ultrasound and elasticity ratio had the highest improvement, from 35.44% to 87.34% for specificity, from 45.74% to 80.77% for positive predictive value, and from 57.72% to 90.24% for accuracy (p shear wave elastography parameters of benign and malignant solid breast masses. By adding shear wave elastography parameters to BI-RADS category 4a masses, we found that about 90% of them could be correctly downgraded to BI-RADS category 3, thereby avoiding biopsy. Elasticity ratio

  14. Extractive Atmospheric Pressure Photoionization (EAPPI) Mass Spectrometry: Rapid Analysis of Chemicals in Complex Matrices.

    Science.gov (United States)

    Liu, Chengyuan; Yang, Jiuzhong; Wang, Jian; Hu, Yonghua; Zhao, Wan; Zhou, Zhongyue; Qi, Fei; Pan, Yang

    2016-10-01

    Extractive atmospheric pressure photoionization (EAPPI) mass spectrometry was designed for rapid qualitative and quantitative analysis of chemicals in complex matrices. In this method, an ultrasonic nebulization system was applied to sample extraction, nebulization, and vaporization. Mixed with a gaseous dopant, vaporized analytes were ionized through ambient photon-induced ion-molecule reactions, and were mass-analyzed by a high resolution time-of-flight mass spectrometer (TOF-MS). After careful optimization and testing with pure sample solution, EAPPI was successfully applied to the fast screening of capsules, soil, natural products, and viscous compounds. Analysis was completed within a few seconds without the need for preseparation. Moreover, the quantification capability of EAPPI for matrices was evaluated by analyzing six polycyclic aromatic hydrocarbons (PAHs) in soil. The correlation coefficients (R (2) ) for standard curves of all six PAHs were above 0.99, and the detection limits were in the range of 0.16-0.34 ng/mg. In addition, EAPPI could also be used to monitor organic chemical reactions in real time. Graphical Abstract ᅟ.

  15. Study on crystalline rock aiming at evaluation method of long-term behavior of rock mass (Joint research)

    International Nuclear Information System (INIS)

    Fukui, Katsunori; Hashiba, Kimihiro; Matsui, Hiroya

    2017-11-01

    It is important to evaluate the stability of a repository for high-level radioactive waste not only during the design, construction and operation phases, but also during the post-closure period, for time frames likely exceeding several millennia or longer. The rock mass around the tunnels could be deformed through time in response to time dependent behavior such as creep and stress relaxation. Therefore, development of methodology to evaluate the past long-term behavior of rock mass is considered to be an issue. In view of above points, this study has been started as a collaboration study with the University of Tokyo from Fiscal Year 2016. In FY 2016, creep testing on Tage tuff was continuously conducted. Existing theory of rate process and stochastic process was modified to be applied to evaluate effects of water, and then the modified theory was validated based on the results of strength and creep tests performed under dry and wet conditions. Furthermore, effects of water contents on stress-strain curves were examined by uniaxial compression testing under various water content conditions. (author)

  16. Analyzed Using Statistical Moments

    International Nuclear Information System (INIS)

    Oltulu, O.

    2004-01-01

    Diffraction enhanced imaging (DEl) technique is a new x-ray imaging method derived from radiography. The method uses a monorheumetten x-ray beam and introduces an analyzer crystal between an object and a detector Narrow angular acceptance of the analyzer crystal generates an improved contrast over the evaluation radiography. While standart radiography can produce an 'absorption image', DEl produces 'apparent absorption' and 'apparent refraction' images with superior quality. Objects with similar absorption properties may not be distinguished with conventional techniques due to close absorption coefficients. This problem becomes more dominant when an object has scattering properties. A simple approach is introduced to utilize scattered radiation to obtain 'pure absorption' and 'pure refraction' images

  17. High-Resolution Mass Spectrometers

    Science.gov (United States)

    Marshall, Alan G.; Hendrickson, Christopher L.

    2008-07-01

    Over the past decade, mass spectrometry has been revolutionized by access to instruments of increasingly high mass-resolving power. For small molecules up to ˜400 Da (e.g., drugs, metabolites, and various natural organic mixtures ranging from foods to petroleum), it is possible to determine elemental compositions (CcHhNnOoSsPp…) of thousands of chemical components simultaneously from accurate mass measurements (the same can be done up to 1000 Da if additional information is included). At higher mass, it becomes possible to identify proteins (including posttranslational modifications) from proteolytic peptides, as well as lipids, glycoconjugates, and other biological components. At even higher mass (˜100,000 Da or higher), it is possible to characterize posttranslational modifications of intact proteins and to map the binding surfaces of large biomolecule complexes. Here we review the principles and techniques of the highest-resolution analytical mass spectrometers (time-of-flight and Fourier transform ion cyclotron resonance and orbitrap mass analyzers) and describe some representative high-resolution applications.

  18. Computerized detection of masses on mammograms by entropy maximization thresholding

    International Nuclear Information System (INIS)

    Kom, Guillaume; Tiedeu, Alain; Feudjio, Cyrille; Ngundam, J.

    2010-03-01

    In many cases, masses in X-ray mammograms are subtle and their detection can benefit from an automated system serving as a diagnostic aid. It is to this end that the authors propose in this paper, a new computer aided mass detection for breast cancer diagnosis. The first step focuses on wavelet filters enhancement which removes bright background due to dense breast tissues and some film artifacts while preserving features and patterns related to the masses. In the second step, enhanced image is computed by Entropy Maximization Thresholding (EMT) to obtain segmented masses. The efficiency of 98,181% is achieved by analyzing a database of 84 mammograms previously marked by radiologists and digitized at a pixel size of 343μmm x 343μ mm. The segmentation results, in terms of size of detected masses, give a relative error on mass area that is less than 8%. The performance of the proposed method has also been evaluated by means of the receiver operating-characteristics (ROC) analysis. This yielded respectively, an area (Az) of 0.9224 and 0.9295 under the ROC curve whether enhancement step is applied or not. Furthermore, we observe that the EMT yields excellent segmentation results compared to those found in literature. (author)

  19. Sonographic evaluation of plantar fasciitis and relation to body mass index

    Energy Technology Data Exchange (ETDEWEB)

    Ozdemir, Huseyin [Department of Radiology Firat University, Faculty of Medicine, Elazig 23119 (Turkey)]. E-mail: ozdemir@firat.edu.tr; Yilmaz, Erhan [Department Orthopedic Firat University, Faculty of Medicine, Elazig (Turkey); Murat, Ayse [Department of Radiology Firat University, Faculty of Medicine, Elazig 23119 (Turkey); Karakurt, Lokman [Department Orthopedic Firat University, Faculty of Medicine, Elazig (Turkey); Poyraz, A. Kursad [Department of Radiology Firat University, Faculty of Medicine, Elazig 23119 (Turkey); Ogur, Erkin [Department of Radiology Firat University, Faculty of Medicine, Elazig 23119 (Turkey)

    2005-06-01

    Purpose: We have investigated the role of sonography in the diagnosis of plantar fasciitis. Materials and methods: This study evaluates 39 patients with plantar fasciitis and control group of 22 healthy volunteers. The plantar fascia thickness was measured 5 mm distal to the insertion of the calcaneus of plantar aponeurosis. Qualitative parameters such as decreased echogenity, biconvexity, perifascial fluid and calcification of plantar fascia were also noted. Results: Mean plantar fascia thickness was measured 2.9 mm in patients with unilateral heel pain, 2.2 mm for contralateral normal heel and 2.5 mm for control group. There was a statistically significant difference between heel with plantar fasciitis, contralateral normal heel and control groups (p = 0.009 and 0.0001, respectively). Mean body mass index was 28 kg/m{sup 2} in patients with heel pain and 25 kg/m{sup 2} in control group. Body mass index measurements were significantly different between plantar fasciitis and control groups. We found reduced plantar fascia echogenity in 16 cases (41%), calcaneal spur in 20 cases (51%), biconvex appearance in two cases (5.1%) and perifascial fluid in one case (2.5%). Conclusion: We conclude that in patients with plantar fasciitis, ultrasound may detect relatively small differences in plantar fascia thickness even in clinically unequivocal plantar fasciitis.

  20. Sonographic evaluation of plantar fasciitis and relation to body mass index

    International Nuclear Information System (INIS)

    Ozdemir, Huseyin; Yilmaz, Erhan; Murat, Ayse; Karakurt, Lokman; Poyraz, A. Kursad; Ogur, Erkin

    2005-01-01

    Purpose: We have investigated the role of sonography in the diagnosis of plantar fasciitis. Materials and methods: This study evaluates 39 patients with plantar fasciitis and control group of 22 healthy volunteers. The plantar fascia thickness was measured 5 mm distal to the insertion of the calcaneus of plantar aponeurosis. Qualitative parameters such as decreased echogenity, biconvexity, perifascial fluid and calcification of plantar fascia were also noted. Results: Mean plantar fascia thickness was measured 2.9 mm in patients with unilateral heel pain, 2.2 mm for contralateral normal heel and 2.5 mm for control group. There was a statistically significant difference between heel with plantar fasciitis, contralateral normal heel and control groups (p = 0.009 and 0.0001, respectively). Mean body mass index was 28 kg/m 2 in patients with heel pain and 25 kg/m 2 in control group. Body mass index measurements were significantly different between plantar fasciitis and control groups. We found reduced plantar fascia echogenity in 16 cases (41%), calcaneal spur in 20 cases (51%), biconvex appearance in two cases (5.1%) and perifascial fluid in one case (2.5%). Conclusion: We conclude that in patients with plantar fasciitis, ultrasound may detect relatively small differences in plantar fascia thickness even in clinically unequivocal plantar fasciitis

  1. Ultrasonographic evaluation of fibroadenoma in the breast: primary signs of mass

    International Nuclear Information System (INIS)

    Yoon, Choon Sik; Kim, Mi Hye; Ahn, Chang Soo; Oh, Ki Keun

    1994-01-01

    To evaluate the ultrasonomammographic findings of breast fibroadenoma. We evaluated the ultrasonographic findings of histopathologically proved 135 fibroadenomas in 103 patients from January 1986 to September 1990, retrospectively. The ultrasonographic examinations were performed with a hand held linear array 5MHz transducer (Acuson 128(USA). Aloka 650, 280(Japan)). Asonopad was also used during the examinations. The common ultrasonographic findings of fibroadenomas usually showed smooth contour in 120 lesions(88.9%), oval or round shape in 114 lesions(84.4%), uniform homogeneous echogenecity in 106 lesions(78.5%), intermediate hypoechoic internal echo pattern in 105 lesions(77.8%), thin boundary echo in 117 lesions(86.7%), lateral shadowings in 97 lesions(72%), and posterior acoustic enhancement in 56 lesions(41%). The longitudinal/transverse ratio of fibroadenoma was revealed between 0.2 and 1.14 (mean 0.58) and usually under 1.0 (68.9%). Finally, most of fibroadenomas are easily diagnosed by ultrasonography but if differential diagnosis from malignant breast mass is difficult due to atypical appearance, other combined modalities such as filmmammography, fine needle aspiration biopsy and MRI are necessary

  2. Ultrasonographic evaluation of fibroadenoma in the breast: primary signs of mass

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Choon Sik; Kim, Mi Hye; Ahn, Chang Soo; Oh, Ki Keun [College of Medicine, Yonsei University, Seoul (Korea, Republic of)

    1994-01-15

    To evaluate the ultrasonomammographic findings of breast fibroadenoma. We evaluated the ultrasonographic findings of histopathologically proved 135 fibroadenomas in 103 patients from January 1986 to September 1990, retrospectively. The ultrasonographic examinations were performed with a hand held linear array 5MHz transducer (Acuson 128(USA). Aloka 650, 280(Japan)). Asonopad was also used during the examinations. The common ultrasonographic findings of fibroadenomas usually showed smooth contour in 120 lesions(88.9%), oval or round shape in 114 lesions(84.4%), uniform homogeneous echogenecity in 106 lesions(78.5%), intermediate hypoechoic internal echo pattern in 105 lesions(77.8%), thin boundary echo in 117 lesions(86.7%), lateral shadowings in 97 lesions(72%), and posterior acoustic enhancement in 56 lesions(41%). The longitudinal/transverse ratio of fibroadenoma was revealed between 0.2 and 1.14 (mean 0.58) and usually under 1.0 (68.9%). Finally, most of fibroadenomas are easily diagnosed by ultrasonography but if differential diagnosis from malignant breast mass is difficult due to atypical appearance, other combined modalities such as filmmammography, fine needle aspiration biopsy and MRI are necessary.

  3. Performance of shear wave elastography for differentiation of benign and malignant solid breast masses.

    Science.gov (United States)

    Li, Guiling; Li, De-Wei; Fang, Yu-Xiao; Song, Yi-Jiang; Deng, Zhu-Jun; Gao, Jian; Xie, Yan; Yin, Tian-Sheng; Ying, Li; Tang, Kai-Fu

    2013-01-01

    To perform a meta-analysis assessing the ability of shear wave elastography (SWE) to identify malignant breast masses. PubMed, the Cochrane Library, and the ISI Web of Knowledge were searched for studies evaluating the accuracy of SWE for identifying malignant breast masses. The diagnostic accuracy of SWE was evaluated according to sensitivity, specificity, and hierarchical summary receiver operating characteristic (HSROC) curves. An analysis was also performed according to the SWE mode used: supersonic shear imaging (SSI) and the acoustic radiation force impulse (ARFI) technique. The clinical utility of SWE for identifying malignant breast masses was evaluated using analysis of Fagan plot. A total of 9 studies, including 1888 women and 2000 breast masses, were analyzed. Summary sensitivities and specificities were 0.91 (95% confidence interval [CI], 0.88-0.94) and 0.82 (95% CI, 0.75-0.87) by SSI and 0.89 (95% CI, 0.81-0.94) and 0.91 (95% CI, 0.84-0.95) by ARFI, respectively. The HSROCs for SSI and ARFI were 0.92 (95% CI, 0.90-0.94) and 0.96 (95% CI, 0.93-0.97), respectively. SSI and ARFI were both very informative, with probabilities of 83% and 91%, respectively, for correctly differentiating between benign and malignant breast masses following a "positive" measurement (over the threshold value) and probabilities of disease as low as 10% and 11%, respectively, following a "negative" measurement (below the threshold value) when the pre-test probability was 50%. SWE could be used as a good identification tool for the classification of breast masses.

  4. Correlation between Body Mass Index, Gender, and Skeletal Muscle Mass Cut off Point in Bandung

    OpenAIRE

    Richi Hendrik Wattimena; Vitriana; Irma Ruslina Defi

    2017-01-01

    Objective: To determine the average skeletal muscle mass (SMM) value in young adults as a reference population; to analyze the correlation of gender, and body mass index to the cut off point; and to determine skeletal muscle mass cut off points of population in Bandung, Indonesia. Methods: This was a cross-sectional study involving 199 participants, 122 females and 77 males. The sampling technique used was the multistage random sampling. The participants were those who lived in four ma...

  5. Air mass origins by back trajectory analysis for evaluating atmospheric 210Pb concentrations at Rokkasho, Aomori, Japan

    International Nuclear Information System (INIS)

    Akata, N.; Kawabata, H.; Hasegawa, H.; Kondo, K.; Chikuchi, Y.; Hisamatsu, S.; Inaba, J.; Sato, T.

    2009-01-01

    Atmospheric concentrations of 210 Pb change with various factors such as meso-scale meteorological conditions. We have already reported the biweekly atmospheric 210 Pb concentrations in Rokkasho, Japan for 5 years and found that they had clear seasonal variations: low concentrations in summer and high values in winter to spring. To study the reasons for the seasonal variations, the origins of the air mass flowing to Rokkasho were analyzed by 3-D backward air mass trajectory analysis. Routes of the calculated trajectories were classified into four regions: northeastern and southeastern Asian Continent, sea and other regions. The atmospheric 210 Pb concentrations were well correlated with the frequency of the routes through the northeastern Asian Continent. A non-linear multiple regression analysis of the 210 Pb concentrations and the relative frequencies of the four routes showed good fitting of the predicted values to the observed ones, and indicated that the atmospheric 210 Pb concentrations in Rokkasho depended on the frequency of the air mass from the northeastern Asian Continent. (author)

  6. Epsilon-Q: An Automated Analyzer Interface for Mass Spectral Library Search and Label-Free Protein Quantification.

    Science.gov (United States)

    Cho, Jin-Young; Lee, Hyoung-Joo; Jeong, Seul-Ki; Paik, Young-Ki

    2017-12-01

    Mass spectrometry (MS) is a widely used proteome analysis tool for biomedical science. In an MS-based bottom-up proteomic approach to protein identification, sequence database (DB) searching has been routinely used because of its simplicity and convenience. However, searching a sequence DB with multiple variable modification options can increase processing time, false-positive errors in large and complicated MS data sets. Spectral library searching is an alternative solution, avoiding the limitations of sequence DB searching and allowing the detection of more peptides with high sensitivity. Unfortunately, this technique has less proteome coverage, resulting in limitations in the detection of novel and whole peptide sequences in biological samples. To solve these problems, we previously developed the "Combo-Spec Search" method, which uses manually multiple references and simulated spectral library searching to analyze whole proteomes in a biological sample. In this study, we have developed a new analytical interface tool called "Epsilon-Q" to enhance the functions of both the Combo-Spec Search method and label-free protein quantification. Epsilon-Q performs automatically multiple spectral library searching, class-specific false-discovery rate control, and result integration. It has a user-friendly graphical interface and demonstrates good performance in identifying and quantifying proteins by supporting standard MS data formats and spectrum-to-spectrum matching powered by SpectraST. Furthermore, when the Epsilon-Q interface is combined with the Combo-Spec search method, called the Epsilon-Q system, it shows a synergistic function by outperforming other sequence DB search engines for identifying and quantifying low-abundance proteins in biological samples. The Epsilon-Q system can be a versatile tool for comparative proteome analysis based on multiple spectral libraries and label-free quantification.

  7. An investigation of electronic states of some molecules and molecular cations using mass analyzed threshold ionization and photoinduced Rydberg ionization spectroscopy

    Science.gov (United States)

    Hofstein, Jason David

    1999-11-01

    Mass analyzed threshold ionization (MATI) experiments have enabled mapping of the n-dependent Rydberg state survival probability for a series of molecules. Utilizing vacuum and extreme ultraviolet (VUV/XUV) photons, one photon Rydberg manifold spectra of argon, hydrogen chloride, nitrogen, benzene, and oxygen were produced, and the prospects of photoinduced Rydberg ionization (PIRI) experiments examined. It was found that the widths of Rydberg manifolds for the molecules studied are quite different. Hydrogen chloride and nitrogen have the narrowest manifold width, followed by benzene, and then oxygen. These varying widths are most strongly correlated with the angular momentum (i.e., quantum defect) of the initially prepared Rydberg orbital. PIRI experiments required the use of a static cell, rather than a molecular jet assembly, for the more efficient production of higher amounts of VUV/XUV radiation, and hence more Rydberg signal needed to observe PIRI. Armed with the ability to produce tunable VUV/XUV radiation, and to determine the feasibility of a PIRI experiment, the MATI and fragment PIRI spectra of trans-1,3-butadiene (BD) were recorded. The MATI spectrum is vibrationally resolved and was analyzed with the help of ab initio calculations and other published results. The fragment PIRI spectrum of the Aproduction of C3H3+ dominates, but at higher photon energies, C2H4 + is also produced. The production of each fragment showed a definite PIRI wavelength dependence.

  8. Video Games as Mass Art

    Directory of Open Access Journals (Sweden)

    Grant Tavinor

    2011-01-01

    Full Text Available Videogames are one of the most significant developments in the mass arts of recent times. In commercial terms, they are now among the most prominent of the mass arts worldwide. This commercial and cultural success does not exhaust the interest in videogames as a mass art phenomenon because games such as Grand Theft Auto IV and Fallout 3 are structurally radically different from previous forms of mass art. In particular, the ontology of videogames, the nature and identity of their works, and how they are instanced and evaluated is a departure from the familiar mass arts of film and popular music. This paper explores these differences in an attempt to fit videogames into a theory of mass art, but also to provide guidance on the issues of criticism and evaluation that surely follow from their ontological distinctiveness.

  9. Quantum chaos and nuclear mass systematics

    International Nuclear Information System (INIS)

    Hirsch, Jorge G.; Velazquez, Victor; Frank, Alejandro

    2004-01-01

    The presence of quantum chaos in nuclear mass systematics is analyzed by considering the differences between measured and calculated nuclear masses as a time series described by the power law 1fα. While for the liquid droplet model plus shell corrections a quantum chaotic behavior α∼1 is found, errors in the microscopic mass formula have α∼0.5, closer to white noise. The chaotic behavior seems to arise from many body effects not included in the mass formula

  10. Image analyzing method to evaluate in situ bioluminescence from an obligate anaerobe cultivated under various dissolved oxygen concentrations.

    Science.gov (United States)

    Ninomiya, Kazuaki; Yamada, Ryuji; Matsumoto, Masami; Fukiya, Satoru; Katayama, Takane; Ogino, Chiaki; Shimizu, Nobuaki

    2013-02-01

    An image analyzing method was developed to evaluate in situ bioluminescence expression, without exposing the culture sample to the ambient oxygen atmosphere. Using this method, we investigated the effect of dissolved oxygen concentration on bioluminescence from an obligate anaerobe Bifidobacterium longum expressing bacterial luciferase which catalyzes an oxygen-requiring bioluminescent reaction. Copyright © 2012 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  11. Added value of shear-wave elastography for evaluation of breast masses detected with screening US imaging.

    Science.gov (United States)

    Lee, Su Hyun; Chang, Jung Min; Kim, Won Hwa; Bae, Min Sun; Seo, Mirinae; Koo, Hye Ryoung; Chu, A Jung; Gweon, Hye Mi; Cho, Nariya; Moon, Woo Kyung

    2014-10-01

    To evaluate the additional value of shear-wave elastography (SWE) to B-mode ultrasonography (US) and to determine an appropriate guideline for the combined assessment of screening US-detected breast masses. This study was conducted with institutional review board approval, and written informed consent was obtained. From March 2010 to February 2012, B-mode US and SWE were performed in 159 US-detected breast masses before biopsy. For each lesion, Breast Imaging Reporting and Data System (BI-RADS) category on B-mode US images and the maximum stiffness color and elasticity values on SWE images were assessed. A guideline for adding SWE data to B-mode US was developed with the retrospective cohort to improve diagnostic performance in sensitivity and specificity and was validated in a distinct prospective cohort of 207 women prior to biopsy. Twenty-one of 159 masses in the development cohort and 12 of 207 breast masses in the validation cohort were malignant. In the development cohort, when BI-RADS category 4a masses showing a dark blue color or a maximum elasticity value of 30 kPa or less on SWE images were downgraded to category 3, specificity increased from 9.4% (13 of 138) to 59.4% (82 of 138) and 57.2% (79 of 138) (P breast masses. BI-RADS category 4a masses detected at US screening that showed a dark blue color or a maximum elasticity value of 30 kPa or less on SWE images can be safely followed up instead of performing biopsy. © RSNA, 2014.

  12. Analyzing THE PLACE FOR THE EVENT-type Metonymies from the Perspective of Negative Evaluative Factors

    Directory of Open Access Journals (Sweden)

    Nami Arimitsu

    Full Text Available This paper has two objectives. First, by analyzing THE PLACE FOR THE EVENT-type metonymies, this paper points out that it is mainly negative events that are expressed by this type of metonymy. Second, this paper reveals the motivations of those THE PLACE FOR THE EVENT-type metonymies that express negative events. Metonymies are widely investigated along with the views of Lakoff and Johnson (1980, and their oppositional semantic aspects are pointed out by Voßhagen (1999. However, none of the previous studies focused on the nature of THE PLACE FOR THE EVENT-type metonymies from the perspective of negative evaluation, euphemism, and politeness. "Let's not let Thailand become another Vietnam" expresses the Vietnam War and all the tragedies behind it. Speakers refrain from expressing negative evaluative aspects from a euphemistic perspective and try to behave politely through hiding the exact expression, and listeners can also easily understand THE PLACE FOR THE EVENT-type metonymies that express negative events, since negative events are much more highly marked and intensified, as well as more prominent, than are positive ones.

  13. Results of the First Mars Organic Molecule Analyzer (MOMA) GC-MS Coupling

    Science.gov (United States)

    Buch, Arnaud; Pinnick, Veronica; Szopa, Cyril; Danell, Ryan; Grand, Noel; Van Amerom, Friso; Glavin, Daniel; Freissinet, Caroline; Humeau, Olivier; Coll, Patrice; Arevalo, Ricardo; Stalport, Fabien; Brinckerhoff, William; Steininger, Harald; Goesmann, Fred; Mahaffy, Paul; Raulin, Francois

    2014-11-01

    The Mars Organic Molecule Analyzer (MOMA) aboard the ExoMars rover will be a key analytical tool in providing chemical (molecular) information from the solid samples collected by the rover, with a particular focus on the char-acterization of the organic content. The core of the MOMA instrument is a gas chromatograph coupled with a mass spectrometer (GC-MS) which provides the unique capability to characterize a broad range of compounds, including both of volatile and non-volatile species. Samples will be crushed and deposited into sample cups seated in a rotating carousel. Soil samples will be analyzed either by UV laser desorption / ionization (LDI) or pyrolysis gas chromatography ion trap mass spectrometry (pyr-GC-ITMS).The French GC brassboard was coupled to the US ion trap mass spectrometer brassboard in a flight-like con-figuration for several coupling campains. The MOMA GC setup is based on the SAM heritage design with a He reservoir and 4 separate analytical modules including traps, columns and Thermal Conductivity Detectors. Solid samples are sealed and heated in this setup using a manual tapping station, designed and built at MPS in Germany, for GC-MS analysis. The gaseous species eluting from the GC are then ionized by an electron impact ionization source in the MS chamber and analyzed by the linear ion trap mass spectrometer. Volatile and non-volatile compounds were injected in the MOMA instrumental suite. Both of these compounds classes were detected by the TCD and by the MS. MS signal (total ion current) and single mass spectra by comparison with the NIST library, gave us an unambiguous confirmation of these identifications. The mass spectra arise from an average of 10 mass spectra averaged around a given time point in the total ion chromatogram.Based on commercial instrument, the MOMA requirement for sensitivity in the GC-MS mode for organic molecules is 1 pmol. In this test, sensitivity was determined for the GC TCD and MS response to a dilution

  14. Evaluation of matrix-assisted laser desorption/ionization time of flight mass spectrometry for the identification of ceratopogonid and culicid larvae.

    Science.gov (United States)

    Steinmann, I C; Pflüger, V; Schaffner, F; Mathis, A; Kaufmann, C

    2013-03-01

    Matrix-assisted laser desorption/ionization time of flight mass spectrometry (MALDI-TOF MS) was evaluated for the rapid identification of ceratopogonid larvae. Optimal sample preparation as evaluated with laboratory-reared biting midges Culicoides nubeculosus was the homogenization of gut-less larvae in 10% formic acid, and analysis of 0.2 mg/ml crude protein homogenate mixed with SA matrix at a ratio of 1:1.5. Using 5 larvae each of 4 ceratopogonid species (C. nubeculosus, C. obsoletus, C. decor, and Dasyhelea sp.) and of 2 culicid species (Aedes aegypti, Ae. japonicus), biomarker mass sets between 27 and 33 masses were determined. In a validation study, 67 larvae belonging to the target species were correctly identified by automated database-based identification (91%) or manual full comparison (9%). Four specimens of non-target species did not yield identification. As anticipated for holometabolous insects, the biomarker mass sets of adults cannot be used for the identification of larvae, and vice versa, because they share only very few similar masses as shown for C. nubeculosus, C. obsoletus, and Ae. japonicus. Thus, protein profiling by MALDI-TOF as a quick, inexpensive and accurate alternative tool is applicable to identify insect larvae of vector species collected in the field.

  15. Endoscopic ultrasound elastography for evaluation of lymph nodes and pancreatic masses: a multicenter study

    DEFF Research Database (Denmark)

    Giovannini, Marc; Thomas, Botelberge; Erwan, Bories

    2009-01-01

    AIM: To evaluate the ability of endoscopic ultrasound (EUS) elastography to distinguish benign from malignant pancreatic masses and lymph nodes. METHODS: A multicenter study was conducted and included 222 patients who underwent EUS examination with assessment of a pancreatic mass (n = 121) or lymph...... node (n = 101). The classification as benign or malignant, based on the real time elastography pattern, was compared with the classification based on the B-mode EUS images and with the final diagnosis obtained by EUS-guided fine needle aspiration (EUS-FNA) and/or by surgical pathology. An interobserver...... study was performed. RESULTS: The sensitivity and specificity of EUS elastography to differentiate benign from malignant pancreatic lesions are 92.3% and 80.0%, respectively, compared to 92.3% and 68.9%, respectively, for the conventional B-mode images. The sensitivity and specificity of EUS...

  16. Tandem mass spectrometry at low kinetic energy

    International Nuclear Information System (INIS)

    Cooks, R.G.; Hand, O.W.

    1987-01-01

    Recent progress in mass spectrometry, as applied to molecular analysis, is reviewed with emphasis on tandem mass spectrometry. Tandem instruments use multiple analyzers (sector magnets, quadrupole mass filters and time-of-flight devices) to select particular molecules in ionic form, react them in the gas-phase and then record the mass, momenta or kinetic energies of their products. The capabilities of tandem mass spectrometry for identification of individual molecules or particular classes of compounds in complex mixtures are illustrated. Several different types of experiments can be run using a tandem mass spectrometer; all share the feature of sifting the molecular mixture being analyzed on the basis of chemical properties expressed in terms of ionic mass, kinetic energy or charge state. Applications of mass spectrometry to biological problems often depend upon desorption methods of ionization in which samples are bombarded with particle beams. Evaporation of preformed charged species from the condensed phase into the vacuum is a particularly effective method of ionization. It is suggested that the use of accelerator mass spectrometers be extended to include problems of molecular analysis. In such experiments, low energy tandem mass spectrometry conducted in the eV or keV range of energies, would be followed by further characterization of the production ion beam using high selective MeV collision processes

  17. On-line mass separator of superheavy atoms

    International Nuclear Information System (INIS)

    Oganesyan, Yu.Ts.

    2002-01-01

    The concept is presented of an on-line Mass Analyzer of SuperHeavy Atoms (MASHA) dedicated to the separation and determination of the mass and decay properties of new elements and isotopes produced in heavy-ion induced reactions. The new nuclides with half-lives T 1/2 ≥ 1 s are transported to an ECR-source working at a frequency of 2.45 GHz and are separated by mass with a mass resolution of M/ΔM ∼ 1500. In the focal plane of the magnetic analyzer a front strip detector surrounded by side detectors will be placed to determine the mass according to the signals from the detected α-particles or fission fragments with efficiency of about 90 %. In comparison to other existing in-flight recoil separators, the present setup will be characterized by higher efficiency and high selectivity relative to background reaction products. The setup MASHA may be used also in the investigation of nuclear reactions of different type induced by stable and radioactive beams

  18. On-Line Mass Separator of Superheavy Atoms

    CERN Document Server

    Oganessian, Yu T

    2002-01-01

    The concept is presented of an on-line Mass Analyzer of SuperHeavy Atoms (MASHA) dedicated to the separation and determination of the mass and decay properties of new elements and isotopes produced in heavy-ion induced reactions. The new nuclides with half-lives T_{1/2}\\ge 1 s are transported to an ECR-source working at a frequency of 2.45 GHz and are separated by mass with a mass resolution of M/\\Delta M\\sim 1500. In the focal plane of the magnetic analyzer a front strip detector surrounded by side detectors will be placed to determine the mass according to the signals from the detected alpha-particles or fission fragments with efficiency of about 90 %. In comparison to other existing in-flight recoil separators, the present setup will be characterized by higher efficiency and high selectivity relative to background reaction products. The setup MASHA may be used also in the investigation of nuclear reactions of different type induced by stable and radioactive beams.

  19. Evaluation of Need and Location for a Thermogravimetric Analyzer in the Plutonium Finishing Plant (PFP) Materials Stabilization

    International Nuclear Information System (INIS)

    WILLIS, H.T.

    2000-01-01

    This plan provides an analysis for locating a TGA to support PFP Thermal Stabilization processes. The scope of this document is to evaluate the need for, and location for, installation of a TGA system as a supplement to the SFE equipment for moisture measurement in pure oxides. A location assessment for the SFE equipment was previously performed (HNF 1999). Based on that assessment, co-location of the TGA system with the SFE system is the preferred option. This would enable thermally stabilized material to be analyzed for residual moisture by either the TGA system or SFE system or both This evaluation considers glovebox locations in the PFP 234-52 Building Analytical Laboratory or operating areas for the installation of the TGA system and it's supporting equipment. This evaluation considers using existing gloveboxes along with an alternative of adding a new glovebox to existing process lines. The location evaluation criteria focuses mainly on glovebox size, with qualitative consideration of relative cost and schedule impacts associated with system implementation, radiological control, and interaction with other laboratory operations and processes. In addition, the possible co-location of a TGA furnace system with the SFE system was considered

  20. PALOMA : an isotope analyzer using static mass spectrometry, coupled with cryogenic and chemical trapping, for the MSL mission to Mars

    Science.gov (United States)

    Chassefiere, E.; Jambon, A.; Berthelier, J.-J.; Goulpeau, G.; Leblanc, F.; Montmessin, F.; Sarda, P.; Agrinier, P.; Fouchet, T.; Waite, H.

    The technique of GCMS analysis has to be completed by static mass spectrometry for precise in-situ measurements of the isotopic composition of planetary atmospheres (noble gases, stable isotopes), and volatile outgassed products from solid sample pyrolysis. Static mass spectrometry, coupled with gas separation by cryo-separation and gettering, is commonly used in the laboratory to study volatiles extracted from terrestrial and meteoritic samples. Such an instrument (PALOMA) is presently developed in our laboratories, and it will be coupled with a Pyr-GCMS analyzer (MACE), built by a US consortium of science laboratories and industrials (University of Michigan, Southwest Research Institute, JPL, Ball Aerospace). The MACE/PALOMA experiment will be proposed on the NASA Mars Science Laboratory mission, planned to be launched in 2009. The scientific objectives of PALOMA, coupled with MACE, may be listed as follows : (i) search for isotopic signatures of past life in atmosphere, rock, dust and ice samples, with emphasis on carbon, nitrogen and hydrogen; (ii) accurately measure isotopic composition of atmospheric noble gases, and stable isotopes, in order to better constrain past escape, surface interaction, outgassing history and climate evolution; (iii) precisely measure diurnal/ seasonal variations of isotopic ratios of H2O, CO2, and N2, for improving our understanding of present and past climate, and of the role of water cycle. Main measurement objectives are : (i) C, H, O, N isotopic composition in both organic evolved samples (provided by MACE pyrolysis system) and atmosphere with high accuracy (a few per mil at 1-s level); (ii) noble gas (He, Ne, Ar, Kr, Xe) and stable (C, H, O, N) isotope composition in atmosphere with high accuracy (a few per mil at 1-s level); (iii) molecular and isotopic composition of inorganic evolved samples (salts, hydrates, nitrates, {ldots}), including ices; (iv) diurnal and seasonal monitoring of D/H in water vapor, and water ice.

  1. Development of parallel/serial program analyzing tool

    International Nuclear Information System (INIS)

    Watanabe, Hiroshi; Nagao, Saichi; Takigawa, Yoshio; Kumakura, Toshimasa

    1999-03-01

    Japan Atomic Energy Research Institute has been developing 'KMtool', a parallel/serial program analyzing tool, in order to promote the parallelization of the science and engineering computation program. KMtool analyzes the performance of program written by FORTRAN77 and MPI, and it reduces the effort for parallelization. This paper describes development purpose, design, utilization and evaluation of KMtool. (author)

  2. Relevance Evaluation of Engineering Master's Program in Peru

    OpenAIRE

    Miñán, Erick; Lavalle, Carlos; Díaz-Puente, José M.

    2012-01-01

    In a context of mass higher education, it is necessary to ensure not only quality but also the relevance of engineering master's programs, namely the appropriateness of the objectives and outcomes to the needs and interests of the program beneficiaries. After a literature review we analyzed the evaluation models of three organizations in Peru: the Board of Evaluation, Accreditation and Certification of the University Education Quality CONEAU, the Institute of Quality and Accreditation of Comp...

  3. Compact Microwave Fourier Spectrum Analyzer

    Science.gov (United States)

    Savchenkov, Anatoliy; Matsko, Andrey; Strekalov, Dmitry

    2009-01-01

    A compact photonic microwave Fourier spectrum analyzer [a Fourier-transform microwave spectrometer, (FTMWS)] with no moving parts has been proposed for use in remote sensing of weak, natural microwave emissions from the surfaces and atmospheres of planets to enable remote analysis and determination of chemical composition and abundances of critical molecular constituents in space. The instrument is based on a Bessel beam (light modes with non-zero angular momenta) fiber-optic elements. It features low power consumption, low mass, and high resolution, without a need for any cryogenics, beyond what is achievable by the current state-of-the-art in space instruments. The instrument can also be used in a wide-band scatterometer mode in active radar systems.

  4. Children's self-perceived bodily competencies and associations with motor skills, body mass index, teachers' evaluations, and parents' concerns

    DEFF Research Database (Denmark)

    Toftegaard-Stoeckel, Jan; Groenfeldt, Vivian; Andersen, Lars Bo

    2010-01-01

    The associations between physical competence, self-perceived bodily competence, parental concern for their children's motor skill development, and teachers' evaluation of their bodily competence were assessed in 646 six- to seven-year-olds. Physical competence was assessed by the German motor...... ability test "Korperkoordinationstest fur Kinder", while the children's, their parents', and their teachers' evaluations were obtained through questionnaires. Parental concern, teacher evaluation, and a high body mass index were the strongest predictors of low physical competence (motor skill quotient ...

  5. The IBM neutrino-mass experiment

    International Nuclear Information System (INIS)

    Clark, G.J.; Frisch, M.A.; Chaudhari, P.; Bregman, M.F.

    1985-01-01

    IBM is undertaking an experiment to measure the electron anti-neutrino mass. A high precision measurement of the tritium Β-decay spectrum near the end point is used to infer the neutrino mass. Electron energies are measured using a large spherical retarding grid analyzer. We are placing particular emphasis on understanding the complications introduced by solid state effects in the source

  6. The IBM neutrino-mass experiment

    International Nuclear Information System (INIS)

    Clark, G.J.; Frisch, M.A.; Chaudhari, P.; Bregman, M.F.

    1985-01-01

    IBM is undertaking an experiment to measure the electron anti-neutrino mass. A high precision measurement of the tritium β-decay spectrum near the end point is used to infer the neutrino mass. Electron energies are measured using a large spherical retarding grid analyzer. They are placing particular emphasis on understanding the complications introduced by solid state effects in the source

  7. Compound-Specific Chlorine Isotope Analysis of Tetrachloromethane and Trichloromethane by Gas Chromatography-Isotope Ratio Mass Spectrometry vs Gas Chromatography-Quadrupole Mass Spectrometry: Method Development and Evaluation of Precision and Trueness.

    Science.gov (United States)

    Heckel, Benjamin; Rodríguez-Fernández, Diana; Torrentó, Clara; Meyer, Armin; Palau, Jordi; Domènech, Cristina; Rosell, Mònica; Soler, Albert; Hunkeler, Daniel; Elsner, Martin

    2017-03-21

    Compound-specific chlorine isotope analysis of tetrachloromethane (CCl 4 ) and trichloromethane (CHCl 3 ) was explored by both, gas chromatography-isotope ratio mass spectrometry (GC-IRMS) and GC-quadrupole MS (GC-qMS), where GC-qMS was validated in an interlaboratory comparison between Munich and Neuchâtel with the same type of commercial GC-qMS instrument. GC-IRMS measurements analyzed CCl isotopologue ions, whereas GC-qMS analyzed the isotopologue ions CCl 3 , CCl 2 , CCl (of CCl 4 ) and CHCl 3 , CHCl 2 , CHCl (of CHCl 3 ), respectively. Lowest amount dependence (good linearity) was obtained (i) in H-containing fragment ions where interference of 35 Cl- to 37 Cl-containing ions was avoided; (ii) with tuning parameters favoring one predominant rather than multiple fragment ions in the mass spectra. Optimized GC-qMS parameters (dwell time 70 ms, 2 most abundant ions) resulted in standard deviations of 0.2‰ (CHCl 3 ) and 0.4‰ (CCl 4 ), which are only about twice as large as 0.1‰ and 0.2‰ for GC-IRMS. To compare also the trueness of both methods and laboratories, samples from CCl 4 and CHCl 3 degradation experiments were analyzed and calibrated against isotopically different reference standards for both CCl 4 and CHCl 3 (two of each). Excellent agreement confirms that true results can be obtained by both methods provided that a consistent set of isotopically characterized reference materials is used.

  8. The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis.

    Science.gov (United States)

    İnce, Fatma Demet; Ellidağ, Hamit Yaşar; Koseoğlu, Mehmet; Şimşek, Neşe; Yalçın, Hülya; Zengin, Mustafa Osman

    2016-08-01

    Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. 209 urine samples were analyzed by the Iris iQ200 ELITE (İris Diagnostics, USA), Dirui FUS-200 (DIRUI Industrial Co., China) automatic urine sediment analyzers and by manual microscopic examination. The degree of concordance (Kappa coefficient) and the rates within the same grading were evaluated. For erythrocytes, leukocytes, epithelial cells, bacteria, crystals and yeasts, the degree of concordance between the two instruments was better than the degree of concordance between the manual microscopic method and the individual devices. There was no concordance between all methods for casts. The results from the automated analyzers for erythrocytes, leukocytes and epithelial cells were similar to the result of microscopic examination. However, in order to avoid any error or uncertainty, some images (particularly: dysmorphic cells, bacteria, yeasts, casts and crystals) have to be analyzed by manual microscopic examination by trained staff. Therefore, the software programs which are used in automatic urine sediment analysers need further development to recognize urinary shaped elements more accurately. Automated systems are important in terms of time saving and standardization.

  9. Matrix effect on the determination of synthetic corticosteroids and diuretics by liquid chromatography-tandem mass spectrometry

    Science.gov (United States)

    Dikunets, M. A.; Appolonova, S. A.; Rodchenkov, G. M.

    2009-04-01

    This work presents a high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) procedure for selective and reliable screening of corticosteroids and diuretics in human urine. Sample preparation included the extraction, evaporation of the organic extract under nitrogen, and solution of the dry residue. The extract was analyzed by HPLC combined with tandem mass spectrometry using electro-spraying ionization at atmospheric pressure with negative ion recording. The mass spectra of all compounds were recorded, and the characteristic ions, retention times, and detection limits were determined. The procedure was validated by evaluating the degree of the matrix suppression of ionization, extraction of analytes from human biological liquid, and the selectivity and specificity of determination.

  10. Quantitative mass-spectrometric analysis of hydrogen helium isotope mixtures

    International Nuclear Information System (INIS)

    Langer, U.

    1998-12-01

    This work deals with the mass-spectrometric method for the quantitative analysis of hydrogen-helium-isotope mixtures, with special attention to fusion plasma diagnostics. The aim was to use the low-resolution mass spectrometry, a standard measuring method which is well established in science and industry. This task is solved by means of the vector mass spectrometry, where a mass spectrum is repeatedly measured, but with stepwise variation of the parameter settings of a quadruple mass spectrometer. In this way, interfering mass spectra can be decomposed and, moreover, it is possible to analyze underestimated mass spectra of complex hydrogen-helium-isotope mixtures. In this work experimental investigations are presented which show that there are different parameters which are suitable for the UMS-method. With an optimal choice of the parameter settings hydrogen-helium-isotope mixtures can be analyzed with an accuracy of 1-3 %. In practice, a low sensitivity for small helium concentration has to be noted. To cope with this task, a method for selective hydrogen pressure reduction has been developed. Experimental investigations and calculations show that small helium amounts (about 1 %) in a hydrogen atmosphere can be analyzed with an accuracy of 3 - 10 %. Finally, this work deals with the effects of the measuring and calibration error on the resulting error in spectrum decomposition. This aspect has been investigated both in general mass-spectrometric gas analysis and in the analysis of hydrogen-helium-mixtures by means of the vector mass spectrometry. (author)

  11. Evaluation and optimization of high-performance liquid chromatography coupled with high-resolution mass spectrometry for phospholipid quantitation.

    Science.gov (United States)

    Fu, Mingkun; Xu, Wei; Lu, Qing; Pan, Guoyu; Varga, Csanad

    2014-04-15

    High-performance liquid chromatography coupled with high-resolution mass spectrometry (HPLC/HRMS) provides an attractive alternative to the traditional triple quadrupole mass spectrometry selected reaction monitoring (SRM) methodology in the field of quantitation. An LTQ Orbitrap Velos mass spectrometer coupled with a Shimadzu UHPLC system was used. A mass extraction window (MEW) was defined to mathematically correlate with mass resolving power (MRP). Five MRP measurement conditions at 7500, 15,000, 30,000, 60,000, and 100,000, and five MEW widths at 10%, 20%, 50%, and 100% of ±1000000/MRP, and were utilized as the experimental conditions. Comparison of profile and centroid algorithms was evaluated as well. Selection of pH 8.5 buffer, C4 column, 20% IPA, and 10 ppm H3 PO4 , minimized hydrophobic and silanol interactions to enhance separation. Narrowing the MEW minimized background noise, while over-narrowing the MEW gave signal loss due to mass accuracy deviation. The mass accuracy deviation was larger for lower MRP measurements especially with centriod data, and hence a profile algorithm was recommended. The post-ionization signal suppression was observed with low MRP and was further confirmed with the analysis of multi-level linearity. It was found that the HPLC/HRMS method with conditions of 20% ±1000000/MRP as MEW, 30,000 or 60,000 MRP, and profile algorithm, provide optimum results for quantitation of seven model phospholipids. Copyright © 2014 John Wiley & Sons, Ltd.

  12. Traceability Assessment and Performance Evaluation of Results for Measurement of Abbott Clinical Chemistry Assays on 4 Chemistry Analyzers.

    Science.gov (United States)

    Lim, Jinsook; Song, Kyung Eun; Song, Sang Hoon; Choi, Hyun-Jung; Koo, Sun Hoe; Kwon, Gye Choel

    2016-05-01

    -The traceability of clinical results to internationally recognized and accepted reference materials and reference measurement procedures has become increasingly important. Therefore, the establishment of traceability has become a mandatory requirement for all in vitro diagnostics devices. -To evaluate the traceability of the Abbott Architect c8000 system (Abbott Laboratories, Abbott Park, Illinois), consisting of calibrators and reagents, across 4 different chemistry analyzers, and to evaluate its general performance on the Toshiba 2000FR NEO (Toshiba Medical Systems Corporation, Otawara-shi, Tochigi-ken, Japan). -For assessment of traceability, secondary reference materials were evaluated 5 times, and then bias was calculated. Precision, linearity, and carryover were determined according to the guidelines of the Clinical and Laboratory Standards Institute (Wayne, Pennsylvania). -The biases from 4 different analyzers ranged from -2.33% to 2.70% on the Toshiba 2000FR NEO, -2.33% to 5.12% on the Roche Hitachi 7600 (Roche Diagnostics International, Basel, Switzerland), -0.93% to 2.87% on the Roche Modular, and -2.16% to 2.86% on the Abbott Architect c16000. The total coefficients of variance of all analytes were less than 5%. The coefficients of determination (R(2)) were more than 0.9900. The carryover rate ranged from -0.54% to 0.17%. -Abbott clinical chemistry assays met the performance criteria based on desirable biological variation for precision, bias, and total error. They also showed excellent linearity and carryover. Therefore, these clinical chemistry assays were found to be accurate and reliable and are readily applicable on the various platforms used in this study.

  13. The art of predicting nuclear masses

    International Nuclear Information System (INIS)

    Hirsch, J.G.; Morales, I.; Mendoza-Temis, J.; Frank, A.; Lopez-Vieyra, J.C.; Barea, J.; Pittel, S.; Van Isacker, P.; Velazquez, V.

    2008-01-01

    A review of recent advances in the theoretical analysis of nuclear mass models and their predictive power is presented. After introducing two tests which probe the ability of nuclear mass models to extrapolate, three models are analyzed in detail: the liquid drop model (LDM), the liquid drop model plus empirical shell corrections (LDMM) and the Duflo–Zuker mass formula (DZ). The DZ model is exhibited as the most predictive model. The Garvey–Kelson mass relations are also discussed. It is shown that their fulfillment probes the consistency of the most commonly used mass formulae, and that they can be used in an iterative process to predict nuclear masses in the neighborhood of nuclei with measured masses, offering a simple and reproducible procedure for short range mass predictions. (author)

  14. Ultrasonographic evaluation of the calf muscle mass and architecture in elderly patients with and without sarcopenia.

    Science.gov (United States)

    Kuyumcu, Mehmet Emin; Halil, Meltem; Kara, Özgür; Çuni, Bledjan; Çağlayan, Gökhan; Güven, Serdar; Yeşil, Yusuf; Arık, Güneş; Yavuz, Burcu Balam; Cankurtaran, Mustafa; Özçakar, Levent

    2016-01-01

    To sonographically assess the muscle mass and architecture of sarcopenic elderly subjects, and to explore the utility of ultrasound (US) measurements in predicting sarcopenia. One hundred elderly subjects were enrolled in this cross-sectional study. Mean age value of our study population was 73.08±6.18years. The diagnosis of sarcopenia was confirmed by measuring fat-free mass index (using bioelectrical impedance analysis) and handgrip strength. Calf circumference was measured and US evaluations comprised bilateral gastrocnemius muscle (MG) thickness, fascicle length and pennate angles; subcutaneous fat and dermis thicknesses in the calf. Bilateral muscle thickness and fascicle length values were significantly lower in patients with sarcopenia (both psarcopenia (all values>76.92%). Gastrocnemius muscle thickness and fascicle length values are lower in sarcopenic elderly and these two parameters can serve as alternative measurements for predicting/quantifying sarcopenia. Calf circumference measurements alone may not be appropriate for assessing sarcopenia. Instead, US imaging can conveniently be used to evaluate different compartments of the musculoskelal system in (sarcopenic) elderly. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  15. Magnetic resonance evaluation of cardiac thrombi and masses by T1 and T2 mapping: an observational study.

    Science.gov (United States)

    Caspar, Thibault; El Ghannudi, Soraya; Ohana, Mickaël; Labani, Aïssam; Lawson, Aubrietia; Ohlmann, Patrick; Morel, Olivier; De Mathelin, Michel; Roy, Catherine; Gangi, Afshin; Germain, Philippe

    2017-04-01

    The purpose of this work was to evaluate CMR T1 and T2 mapping sequences in patients with intracardiac thrombi and masses in order to assess T1 and T2 relaxometry usefulness and to allow better etiological diagnosis. This observational study of patients scheduled for routine CMR was performed from September 2014 to August 2015. All patients referred to our department for a 1.5 T CMR were screened to participate. T1 mapping were acquired before and after Gadolinium injection; T2 mapping images were obtained before injection. 41 patients were included. 22 presented with cardiac thrombi and 19 with cardiac masses. The native T1 of thrombi was 1037 ± 152 ms (vs 1032 ± 39 ms for myocardium, p = 0.88; vs 1565 ± 88 ms for blood pool, p T2 were 74 ± 13 ms (vs 51 ± 3 ms for myocardium, p T2 consistently >70 ms. T1 and T2 mapping CMR sequences can be useful and represent a new approach for the evaluation of cardiac thrombi and masses.

  16. Evaluation of information-theoretic similarity measures for content-based retrieval and detection of masses in mammograms

    International Nuclear Information System (INIS)

    Tourassi, Georgia D.; Harrawood, Brian; Singh, Swatee; Lo, Joseph Y.; Floyd, Carey E.

    2007-01-01

    The purpose of this study was to evaluate image similarity measures employed in an information-theoretic computer-assisted detection (IT-CAD) scheme. The scheme was developed for content-based retrieval and detection of masses in screening mammograms. The study is aimed toward an interactive clinical paradigm where physicians query the proposed IT-CAD scheme on mammographic locations that are either visually suspicious or indicated as suspicious by other cuing CAD systems. The IT-CAD scheme provides an evidence-based, second opinion for query mammographic locations using a knowledge database of mass and normal cases. In this study, eight entropy-based similarity measures were compared with respect to retrieval precision and detection accuracy using a database of 1820 mammographic regions of interest. The IT-CAD scheme was then validated on a separate database for false positive reduction of progressively more challenging visual cues generated by an existing, in-house mass detection system. The study showed that the image similarity measures fall into one of two categories; one category is better suited to the retrieval of semantically similar cases while the second is more effective with knowledge-based decisions regarding the presence of a true mass in the query location. In addition, the IT-CAD scheme yielded a substantial reduction in false-positive detections while maintaining high detection rate for malignant masses

  17. Uncertainty in decision models analyzing cost-effectiveness : The joint distribution of incremental costs and effectiveness evaluated with a nonparametric bootstrap method

    NARCIS (Netherlands)

    Hunink, Maria; Bult, J.R.; De Vries, J; Weinstein, MC

    1998-01-01

    Purpose. To illustrate the use of a nonparametric bootstrap method in the evaluation of uncertainty in decision models analyzing cost-effectiveness. Methods. The authors reevaluated a previously published cost-effectiveness analysis that used a Markov model comparing initial percutaneous

  18. Development and evaluation of a computer-aided system for analyzing human error in railway operations

    International Nuclear Information System (INIS)

    Kim, Dong San; Baek, Dong Hyun; Yoon, Wan Chul

    2010-01-01

    As human error has been recognized as one of the major contributors to accidents in safety-critical systems, there has been a strong need for techniques that can analyze human error effectively. Although many techniques have been developed so far, much room for improvement remains. As human error analysis is a cognitively demanding and time-consuming task, it is particularly necessary to develop a computerized system supporting this task. This paper presents a computer-aided system for analyzing human error in railway operations, called Computer-Aided System for Human Error Analysis and Reduction (CAS-HEAR). It supports analysts to find multiple levels of error causes and their causal relations by using predefined links between contextual factors and causal factors as well as links between causal factors. In addition, it is based on a complete accident model; hence, it helps analysts to conduct a thorough analysis without missing any important part of human error analysis. A prototype of CAS-HEAR was evaluated by nine field investigators from six railway organizations in Korea. Its overall usefulness in human error analysis was confirmed, although development of its simplified version and some modification of the contextual factors and causal factors are required in order to ensure its practical use.

  19. The mass-lifetime relation

    Science.gov (United States)

    LoPresto, Michael C.

    2018-05-01

    In a recent "AstroNote," I described a simple exercise on the mass-luminosity relation for main sequence stars as an example of exposing students in a general education science course of lower mathematical level to the use of quantitative skills such as collecting and analyzing data. Here I present another attempt at a meaningful experience for such students that again involves both the gathering and analysis of numerical data and comparison with accepted result, this time on the relationship of the mass and lifetimes of main sequence stars. This experiment can stand alone or be used as an extension of the previous mass-luminosity relationship experiment.

  20. Evaluation of ultrasound-assisted extraction as sample pre-treatment for quantitative determination of rare earth elements in marine biological tissues by inductively coupled plasma-mass spectrometry

    International Nuclear Information System (INIS)

    Costas, M.; Lavilla, I.; Gil, S.; Pena, F.; Calle, I.; Cabaleiro, N. de la; Bendicho, C.

    2010-01-01

    In this work, the determination of rare earth elements (REEs), i.e. Y, La, Ce, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb and Lu in marine biological tissues by inductively coupled-mass spectrometry (ICP-MS) after a sample preparation method based on ultrasound-assisted extraction (UAE) is described. The suitability of the extracts for ICP-MS measurements was evaluated. For that, studies were focused on the following issues: (i) use of clean up of extracts with a C18 cartridge for non-polar solid phase extraction; (ii) use of different internal standards; (iii) signal drift caused by changes in the nebulization efficiency and salt deposition on the cones during the analysis. The signal drift produced by direct introduction of biological extracts in the instrument was evaluated using a calibration verification standard for bracketing (standard-sample bracketing, SSB) and cumulative sum (CUSUM) control charts. Parameters influencing extraction such as extractant composition, mass-to-volume ratio, particle size, sonication time and sonication amplitude were optimized. Diluted single acids (HNO 3 and HCl) and mixtures (HNO 3 + HCl) were evaluated for improving the extraction efficiency. Quantitative recoveries for REEs were achieved using 5 mL of 3% (v/v) HNO 3 + 2% (v/v) HCl, particle size <200 μm, 3 min of sonication time and 50% of sonication amplitude. Precision, expressed as relative standard deviation from three independent extractions, ranged from 0.1 to 8%. In general, LODs were improved by a factor of 5 in comparison with those obtained after microwave-assisted digestion (MAD). The accuracy of the method was evaluated using the CRM BCR-668 (mussel tissue). Different seafood samples of common consumption were analyzed by ICP-MS after UAE and MAD.

  1. On-line probe for fast electrochemistry/electrospray mass spectrometry. Investigation of polycyclic aromatic hydrocarbons.

    Science.gov (United States)

    Xu, X; Lu, W; Cole, R B

    1996-12-01

    A newly invented probe accessory for fast electrochemistry/electrospray mass spectrometry (EC/ESMS) is presented and evaluated. The device features a low-volume, three-electrode electrochemical cell which has been designed with a minimum distance between the working electrode and the "Taylor cone" inherent to the electrospray process. This configuration limits the time between electrochemical generation of ions and mass spectrometric analysis to an absolute minimum. A fused-silica layer insulates the microcylinder working electrode from the sample solution until immediately prior to the electrospray region, postponing electrode processes until the last moment. The same fused-silica layer insulates the working electrode from the surrounding auxiliary electrode, a stainless steel capillary that also serves as the electrospray capillary. The performance and capabilities of the novel electrochemistry/electrospray mass spectrometry system have been evaluated using polycyclic aromatic hydrocarbons (PAHs) as test analytes. In the positive ion EC/ESMS mode, oxidized forms (one-electron removal) of PAHs are produced in high yield. The ability to analyze reaction products appearing subsequent to the initial oxidation is also demonstrated.

  2. Direct gas injection method: A simple modification to an elemental analyzer/isotope ratio mass spectrometer for stable isotope analysis of N and C from N2O and CO2 gases in nanomolar concentrations

    Science.gov (United States)

    A simple modification to the Elemental Analyzer coupled to Isotope Ratio Mass-Spectrometer (EA-IRMS) setup is described. This modification allows the users to measure nitrous oxide (N2O) and carbon dioxide (CO2) by injecting the gases directly into an online injector placed befor...

  3. Performance of Shear Wave Elastography for Differentiation of Benign and Malignant Solid Breast Masses

    Science.gov (United States)

    Song, Yi-Jiang; Deng, Zhu-Jun; Gao, Jian; Xie, Yan; Yin, Tian-Sheng; Ying, Li; Tang, Kai-Fu

    2013-01-01

    Objectives To perform a meta-analysis assessing the ability of shear wave elastography (SWE) to identify malignant breast masses. Methods PubMed, the Cochrane Library, and the ISI Web of Knowledge were searched for studies evaluating the accuracy of SWE for identifying malignant breast masses. The diagnostic accuracy of SWE was evaluated according to sensitivity, specificity, and hierarchical summary receiver operating characteristic (HSROC) curves. An analysis was also performed according to the SWE mode used: supersonic shear imaging (SSI) and the acoustic radiation force impulse (ARFI) technique. The clinical utility of SWE for identifying malignant breast masses was evaluated using analysis of Fagan plot. Results A total of 9 studies, including 1888 women and 2000 breast masses, were analyzed. Summary sensitivities and specificities were 0.91 (95% confidence interval [CI], 0.88–0.94) and 0.82 (95% CI, 0.75–0.87) by SSI and 0.89 (95% CI, 0.81–0.94) and 0.91 (95% CI, 0.84–0.95) by ARFI, respectively. The HSROCs for SSI and ARFI were 0.92 (95% CI, 0.90–0.94) and 0.96 (95% CI, 0.93–0.97), respectively. SSI and ARFI were both very informative, with probabilities of 83% and 91%, respectively, for correctly differentiating between benign and malignant breast masses following a “positive” measurement (over the threshold value) and probabilities of disease as low as 10% and 11%, respectively, following a “negative” measurement (below the threshold value) when the pre-test probability was 50%. Conclusions SWE could be used as a good identification tool for the classification of breast masses. PMID:24204613

  4. Performance of shear wave elastography for differentiation of benign and malignant solid breast masses.

    Directory of Open Access Journals (Sweden)

    Guiling Li

    Full Text Available OBJECTIVES: To perform a meta-analysis assessing the ability of shear wave elastography (SWE to identify malignant breast masses. METHODS: PubMed, the Cochrane Library, and the ISI Web of Knowledge were searched for studies evaluating the accuracy of SWE for identifying malignant breast masses. The diagnostic accuracy of SWE was evaluated according to sensitivity, specificity, and hierarchical summary receiver operating characteristic (HSROC curves. An analysis was also performed according to the SWE mode used: supersonic shear imaging (SSI and the acoustic radiation force impulse (ARFI technique. The clinical utility of SWE for identifying malignant breast masses was evaluated using analysis of Fagan plot. RESULTS: A total of 9 studies, including 1888 women and 2000 breast masses, were analyzed. Summary sensitivities and specificities were 0.91 (95% confidence interval [CI], 0.88-0.94 and 0.82 (95% CI, 0.75-0.87 by SSI and 0.89 (95% CI, 0.81-0.94 and 0.91 (95% CI, 0.84-0.95 by ARFI, respectively. The HSROCs for SSI and ARFI were 0.92 (95% CI, 0.90-0.94 and 0.96 (95% CI, 0.93-0.97, respectively. SSI and ARFI were both very informative, with probabilities of 83% and 91%, respectively, for correctly differentiating between benign and malignant breast masses following a "positive" measurement (over the threshold value and probabilities of disease as low as 10% and 11%, respectively, following a "negative" measurement (below the threshold value when the pre-test probability was 50%. CONCLUSIONS: SWE could be used as a good identification tool for the classification of breast masses.

  5. Diagnostic performance of sonoelastographic Tsukuba score and strain ratio in evaluation of breast masses

    Directory of Open Access Journals (Sweden)

    Mahmoud Abd Elaziz Dawood

    2018-03-01

    Full Text Available The aim of this prospective study was to evaluate the diagnostic performance of the use of strain index ratio by sonoelastography to differentiate between benign and malignant breast lesions. Patients & Methods: This prospective study including 40 females, complaining of breast masses which were suspicious to be malignant on clinical examination. All patients were submitted to B-mode Ultrasound and sonoelastography. Biopsy as a gold standard and pathological study were done for all breast lesions. Results: US examination of every mass was done and categorized according to BI-RADS categories according to ACR2013, according to US lexicon. Sonoelastography examination with Lesions classification was performed on the basis of a 5-point scoring method proposed by Tsukuba elasticity score. Then measurements of strain ratio were done. Statistical analysis of combination of the three methods was sensitivity of 96.7%, specificity of 100% when we use cut off value of 3–4 in elastography score and ≤3 cut off value of strain ratio. Conclusion: The combined use of strain ratio with Tsukuba score and BI-RADS categorization increased the diagnostic performance in differentiation between benign and malignant breast lesions. Keywords: Elastography, Breast masses, Strain ratio, Ultrasound, BI-RADS classification, Tsukuba score

  6. Mass-Like Fibrocystic Disease of the Breast : Characteristic Findings on Mammogram and Sonogram

    International Nuclear Information System (INIS)

    KIm, Hyeon Hee; Yun, Duk Hee; Hwang, Ho Kyumg; Kim, Jang Min; Kim, Young Sun; Lee, Jung Hee

    1995-01-01

    This study was performed to evaluate the mammographic and sonographic features of mass-like fibrocystic disease of the breast to differentiate from other breast mass. We retrospectively analyzed characteristics mammographic(16 cases) and sonographic findings(39 cases) of histopathologically proven mass-like fibrocystic disease of the breast in 39 patients. Of 16 patients with mammogram, mass-like fibrocystic disease of the breast was round shape in 12 cases, high density in 14 cases.The margin of the mass was well marginated in 8 cases, poorly marginated in 8 cases. The calcification within the mass was not detected in 13 cases. In 39 patients with sonogram, mass-like fibrocystic disease of the breast was mostly ovoid shape in 24 cases, hypoechoic in 23 cases, with homogenous internal echo in 36 cases, well defined in 28 cases, and with equivocal posterior shadowing in 26 cases. The T/AP ratios of the mass was not less than 1.5 in 29 cases. The bilateral edge-shadowing of the mass was not noted in 24 cases. Characteristic findings of the mass-like fibrocystic disease of the breast are round shape, high density, well defined mass on mammograrn and ovoid shape, homogeneous internal echo, well marginated mass on sonogram which were similar to those in other benign lesion. Mass-like fibrocystic disease, which in a frequent cause of breast lumps, should be included in the differential diagnosis of breast mass with benign mammographic and/or sonographic findings

  7. Mass-Like Fibrocystic Disease of the Breast : Characteristic Findings on Mammogram and Sonogram

    Energy Technology Data Exchange (ETDEWEB)

    KIm, Hyeon Hee; Yun, Duk Hee; Hwang, Ho Kyumg; Kim, Jang Min; Kim, Young Sun; Lee, Jung Hee [Kwang Myung Sung Ae Hospital, Gwangmyeong (Korea, Republic of)

    1995-12-15

    This study was performed to evaluate the mammographic and sonographic features of mass-like fibrocystic disease of the breast to differentiate from other breast mass. We retrospectively analyzed characteristics mammographic(16 cases) and sonographic findings(39 cases) of histopathologically proven mass-like fibrocystic disease of the breast in 39 patients. Of 16 patients with mammogram, mass-like fibrocystic disease of the breast was round shape in 12 cases, high density in 14 cases.The margin of the mass was well marginated in 8 cases, poorly marginated in 8 cases. The calcification within the mass was not detected in 13 cases. In 39 patients with sonogram, mass-like fibrocystic disease of the breast was mostly ovoid shape in 24 cases, hypoechoic in 23 cases, with homogenous internal echo in 36 cases, well defined in 28 cases, and with equivocal posterior shadowing in 26 cases. The T/AP ratios of the mass was not less than 1.5 in 29 cases. The bilateral edge-shadowing of the mass was not noted in 24 cases. Characteristic findings of the mass-like fibrocystic disease of the breast are round shape, high density, well defined mass on mammograrn and ovoid shape, homogeneous internal echo, well marginated mass on sonogram which were similar to those in other benign lesion. Mass-like fibrocystic disease, which in a frequent cause of breast lumps, should be included in the differential diagnosis of breast mass with benign mammographic and/or sonographic findings

  8. Ion optics of a high resolution multipassage mass spectrometer with electrostatic ion mirrors

    Energy Technology Data Exchange (ETDEWEB)

    Sakurai, T [Osaka Univ. (Japan). Dept. of Physics; Baril, M [Departement de Physique, Faculte des Sciences et de Genie, Universite Laval, Ste-Foy, Quebec G1K 7P4 (Canada)

    1995-09-01

    Ion trajectories in an electrostatic ion mirror are calculated. The interferences of the extended fringing fields of the mirror with finite aperture are studied. The results of the calculations are represented by three transfer matrices, which describe ion trajectories under the effects of a fringing field at the entrances, of an idealized mirror region, and of a fringing field at the exit. The focusing effects and ion-optical properties of mass spectrometers with electrostatic ion mirrors can be evaluated by using these transfer matrices. A high performance multipassage mass spectrometer is designed. The system has one magnet and four electrostatic sector analyzers and two ion mirrors. The double focusing condition and stigmatic focusing condition are achieved in any passage of the system. The mass resolution increases linearly with the number of passages in a magnet. (orig.).

  9. Noise and analyzer-crystal angular position analysis for analyzer-based phase-contrast imaging

    Science.gov (United States)

    Majidi, Keivan; Li, Jun; Muehleman, Carol; Brankov, Jovan G.

    2014-04-01

    The analyzer-based phase-contrast x-ray imaging (ABI) method is emerging as a potential alternative to conventional radiography. Like many of the modern imaging techniques, ABI is a computed imaging method (meaning that images are calculated from raw data). ABI can simultaneously generate a number of planar parametric images containing information about absorption, refraction, and scattering properties of an object. These images are estimated from raw data acquired by measuring (sampling) the angular intensity profile of the x-ray beam passed through the object at different angular positions of the analyzer crystal. The noise in the estimated ABI parametric images depends upon imaging conditions like the source intensity (flux), measurements angular positions, object properties, and the estimation method. In this paper, we use the Cramér-Rao lower bound (CRLB) to quantify the noise properties in parametric images and to investigate the effect of source intensity, different analyzer-crystal angular positions and object properties on this bound, assuming a fixed radiation dose delivered to an object. The CRLB is the minimum bound for the variance of an unbiased estimator and defines the best noise performance that one can obtain regardless of which estimation method is used to estimate ABI parametric images. The main result of this paper is that the variance (hence the noise) in parametric images is directly proportional to the source intensity and only a limited number of analyzer-crystal angular measurements (eleven for uniform and three for optimal non-uniform) are required to get the best parametric images. The following angular measurements only spread the total dose to the measurements without improving or worsening CRLB, but the added measurements may improve parametric images by reducing estimation bias. Next, using CRLB we evaluate the multiple-image radiography, diffraction enhanced imaging and scatter diffraction enhanced imaging estimation techniques

  10. Noise and analyzer-crystal angular position analysis for analyzer-based phase-contrast imaging

    International Nuclear Information System (INIS)

    Majidi, Keivan; Brankov, Jovan G; Li, Jun; Muehleman, Carol

    2014-01-01

    The analyzer-based phase-contrast x-ray imaging (ABI) method is emerging as a potential alternative to conventional radiography. Like many of the modern imaging techniques, ABI is a computed imaging method (meaning that images are calculated from raw data). ABI can simultaneously generate a number of planar parametric images containing information about absorption, refraction, and scattering properties of an object. These images are estimated from raw data acquired by measuring (sampling) the angular intensity profile of the x-ray beam passed through the object at different angular positions of the analyzer crystal. The noise in the estimated ABI parametric images depends upon imaging conditions like the source intensity (flux), measurements angular positions, object properties, and the estimation method. In this paper, we use the Cramér–Rao lower bound (CRLB) to quantify the noise properties in parametric images and to investigate the effect of source intensity, different analyzer-crystal angular positions and object properties on this bound, assuming a fixed radiation dose delivered to an object. The CRLB is the minimum bound for the variance of an unbiased estimator and defines the best noise performance that one can obtain regardless of which estimation method is used to estimate ABI parametric images. The main result of this paper is that the variance (hence the noise) in parametric images is directly proportional to the source intensity and only a limited number of analyzer-crystal angular measurements (eleven for uniform and three for optimal non-uniform) are required to get the best parametric images. The following angular measurements only spread the total dose to the measurements without improving or worsening CRLB, but the added measurements may improve parametric images by reducing estimation bias. Next, using CRLB we evaluate the multiple-image radiography, diffraction enhanced imaging and scatter diffraction enhanced imaging estimation techniques

  11. Light baryon masses with dynamical twisted mass fermions

    Energy Technology Data Exchange (ETDEWEB)

    Alexandrou, C. [Cyprus Univ., Nicosia (Cyprus). Dept. of Physics; Baron, R. [CEA-Saclay, IRFU/Service de Physique Nucleaire, Gif-sur-Yvette (France); Blossier, B. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (DE). John von Neumann-Inst. fuer Computing NIC] (and others)

    2008-03-15

    We present results on the mass of the nucleon and the {delta} using two dynamical degenerate twisted mass quarks. The evaluation is performed at four quark masses corresponding to a pion mass in the range of about 300-600 MeV on lattices of 2.1-2.7 fm. We check for cut-off effects by evaluating these baryon masses on lattices of spatial size 2.1 fm at {beta}=3.9 and {beta}=4.05 and on a lattice of 2.4 fm at {beta}=3.8. The values we find are compatible within our statistical errors. Lattice results are extrapolated to the physical limit using continuum chiral perturbation theory. Performing a combined fit to our lattice data at {beta}=3.9 and {beta}=4.05 we find a nucleon mass of 964{+-}28(stat.){+-}8(syst.) MeV where we used the lattice spacings determined from the pion decay constant to convert to physical units. The systematic error due to the chiral extrapolation is estimated by comparing results obtained at O(p{sup 3}) and O(p{sup 4}) heavy baryon chiral perturbation theory. The nucleon mass at the physical point provides an independent determination of the lattice spacing. Using heavy baryon chiral perturbation theory at O(p{sup 3}) we find a{sub {beta}}{sub =3.9}=0.0890{+-}0.0039(stat.){+-}0.0014(syst.) fm, and a{sub {beta}}{sub =4.05}=0.0691{+-}0.0034(stat.){+-}0.0010(syst.) fm, in good agreement with the values determined from the pion decay constant. Using results from our two smaller lattices spacings at constant r0m we estimate the continuum limit and check consistency with results from the coarser lattice. Results at the continuum limit are chirally extrapolated to the physical point. Isospin violating lattice artifacts in the {delta}-system are found to be compatible with zero for the values of the lattice spacings used in this work. Performing a combined fit to our lattice data at {beta}=3.9 and {beta}=4.05 we find for the masses of the {delta}{sup ++,-} and {delta}{sup +,0} 1316{+-}60(stat.) MeV and 1330{+-}74(stat.) MeV respectively. We confirm

  12. Light baryon masses with dynamical twisted mass fermions

    International Nuclear Information System (INIS)

    Alexandrou, C.; Blossier, B.

    2008-03-01

    We present results on the mass of the nucleon and the Δ using two dynamical degenerate twisted mass quarks. The evaluation is performed at four quark masses corresponding to a pion mass in the range of about 300-600 MeV on lattices of 2.1-2.7 fm. We check for cut-off effects by evaluating these baryon masses on lattices of spatial size 2.1 fm at β=3.9 and β=4.05 and on a lattice of 2.4 fm at β=3.8. The values we find are compatible within our statistical errors. Lattice results are extrapolated to the physical limit using continuum chiral perturbation theory. Performing a combined fit to our lattice data at β=3.9 and β=4.05 we find a nucleon mass of 964±28(stat.)±8(syst.) MeV where we used the lattice spacings determined from the pion decay constant to convert to physical units. The systematic error due to the chiral extrapolation is estimated by comparing results obtained at O(p 3 ) and O(p 4 ) heavy baryon chiral perturbation theory. The nucleon mass at the physical point provides an independent determination of the lattice spacing. Using heavy baryon chiral perturbation theory at O(p 3 ) we find a β=3.9 =0.0890±0.0039(stat.)±0.0014(syst.) fm, and a β=4.05 =0.0691±0.0034(stat.)±0.0010(syst.) fm, in good agreement with the values determined from the pion decay constant. Using results from our two smaller lattices spacings at constant r0m we estimate the continuum limit and check consistency with results from the coarser lattice. Results at the continuum limit are chirally extrapolated to the physical point. Isospin violating lattice artifacts in the Δ-system are found to be compatible with zero for the values of the lattice spacings used in this work. Performing a combined fit to our lattice data at β=3.9 and β=4.05 we find for the masses of the Δ ++,- and Δ +,0 1316±60(stat.) MeV and 1330±74(stat.) MeV respectively. We confirm that in the continuum limit they are also degenerate. (orig.)

  13. Degradation studies of quizalofop-p and related compounds in soils using liquid chromatography coupled to low and high resolution mass analyzers.

    Science.gov (United States)

    López-Ruiz, Rosalía; Romero-González, Roberto; Martínez Vidal, José Luis; Fernández-Pérez, Manuel; Garrido Frenich, Antonia

    2017-12-31

    A comprehensive degradation study of quizalofop-p, quizalofop-p-ethyl, quizalofop-p-tefuryl and propaquizafop in soil samples have been firstly performed using ultra high performance liquid chromatography coupled to Orbitrap mass spectrometry (UHPLC-Orbitrap-MS). Thus, metabolites or degradation products, such as CHHQ (dihydroxychloroquinoxalin), CHQ (6-chloroquinoxalin-2-ol), PPA ((R)-2-(4-hydroxyphenoxy)propionic acid) and 2,3-dihydroxyquinoxaline were also monitored. An extraction procedure based on QuEChERS procedure was used. Acidified water (0.1M hydrochloric acid) and acidified acetonitrile (1% acetic acid, (v/v)) were used as extraction solvents, and magnesium sulfate and sodium chloride were used as salts. Dispersive solid phase extraction with C 18 as sorbent, was needed as a clean-up step. Several commercial products (Panarex®, Master-D® and Dixon®) were used to evaluate the degradation of the target compounds into their metabolites. The concentration of the main active substances (quizalofop-p-tefuryl, quizalofop-p-ethyl and propaquizafop) decreased during the degradation studies, whereas the concentration of quizalofop-p increased. Dissipation rates of half-live of quizalofop-p were also evaluated, and it was observed that this compound is easily degraded, obtaining values lower than 1day. Taking into account that quizalofop-p is the R enantiomer of quizalofop, a chiral separation was performed by liquid chromatography coupled to tandem mass spectrometry, concluding that in samples containing quizalofop-p-tefuryl, there was a 15% contribution from the S enantiomer and a 85% contribution from the R enantiomer. Metabolites such as PPA, CHHQ and CHQ were detected in soil samples after 15days of application commercial product at concentrations between the limits of detection (LOD) and the limits of quantification (LOQ). CHQ and CHHQ were detected at concentrations higher than the LOQ in samples after 50 and 80days of application, with their

  14. Technetium-99m methylene diphosphonate scintimammography for evaluation of palpable breast masses

    International Nuclear Information System (INIS)

    Shah, S.; Khan, M.M.; Khan, A.U.; Khan, S.M.; Khan, A.A.

    2002-01-01

    Objective:To evaluate technetium-99m methylene diphosphonate (/sup 99m/Tc-MDP) as a noninvasive tumor-localizing agent in patients with palpable breast masses and to differentiate malignant from benign breast lesions. Design: It was an observational and experimental study. Place and Duration of Study: the study was conducted at the Institute of Radiotherapy and Nuclear Medicine (IRNUM), Peshawar during a six-month period (June to November, 1995). Subjects and Methods: 99m Tc-MDP scintimammography (SMM) was performed in thirty patients with palpable breast masses (Group A). Ten patients with no palpable breast abnormality (Group B) also underwent /sup 99m/Tc-MDP breast study; they served as controls. Upright anterior, lateral and oblique lateral images of the breasts were acquired 10-30 minutes after intravenous injection of 740 MBq of /sup 99m/Tc-MDP. This was performed during routine bone scanning. SMM was followed by surgical and /or needle biopsy. Results: breast cancer was histologically diagnosed in twenty two (73%), and benign disease found in eight patients (27%). Of the twenty two breast carcinomas, twenty (91%) were detected using /sup 99m/Tc-MDP SMM, while no uptake was seen in two (9%). Of the eight patients with pathologically proven benign breast lesions, seven (88%) either did not show any uptake or showed faint bilateral accumulation. Focal /sup 99m/Tc-MDP uptake was observed in one fibroadenoma. Conclusion: The study showed that SMM with /sup 99m/Tc-MDP is positive in a high percentage of patients with carcinoma of the breast and may differentiate malignant from benign masses. (author)

  15. Usefulness of MALDI-TOF mass spectrometry in epidemiological control of etiologic agents of infection

    Directory of Open Access Journals (Sweden)

    Roberto Degl’Innocenti

    2013-08-01

    Full Text Available Introduction: The use of the MALDI-TOF mass spectrometry in the routine of microbiological diagnostics has revolutionized procedures and response times of bacteriology.The use of this technique aims to epidemiological investigations in a hospital environment and represents a further significant opportunity, quickly feasible and extremely economical. Methods: By means of the MALDI-TOF-MS Vitek2 (MS Vitek2 mass spectrometer, accompanied by the AgnosTec-SARAMIS (bioMérieux, France software, were analyzed the spectra of 149 bacterial isolates (139 Staphylococcus aureus and 10 Staphylococcus epidermidis obtained from cultures of 148 patients (141 inpatients and 7 outpatients. Clinical isolates were stored at a temperature of -20°C.The isolates were then thawed and immediately cultured on agar blood medium. The colonies were subjected to analysis by MS Vitek on the day after sowing. The spectra obtained were analyzed and compared using the software AgnosTec-SARAMIS, which allowed the construction of a dendrogram. Results and conclusions: The evaluation of the data collected suggests that mass spectrometry could be an useful tool in epidemiological surveys. Speed of analysis and low costs make the MS Vitek2 an usable tool by many microbiology laboratories.

  16. Accurate mass measurements on neutron-deficient krypton isotopes

    CERN Document Server

    Rodríguez, D.; Äystö, J.; Beck, D.; Blaum, K.; Bollen, G.; Herfurth, F.; Jokinen, A.; Kellerbauer, A.; Kluge, H.-J.; Kolhinen, V.S.; Oinonen, M.; Sauvan, E.; Schwarz, S.

    2006-01-01

    The masses of $^{72–78,80,82,86}$Kr were measured directly with the ISOLTRAP Penning trap mass spectrometer at ISOLDE/CERN. For all these nuclides, the measurements yielded mass uncertainties below 10 keV. The ISOLTRAP mass values for $^{72–75}$Kr being more precise than the previous results obtained by means of other techniques, and thus completely determine the new values in the Atomic-Mass Evaluation. Besides the interest of these masses for nuclear astrophysics, nuclear structure studies, and Standard Model tests, these results constitute a valuable and accurate input to improve mass models. In this paper, we present the mass measurements and discuss the mass evaluation for these Kr isotopes.

  17. Computer-aided detection system for masses in automated whole breast ultrasonography: development and evaluation of the effectiveness

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeoung Hyun [Dept. of Radiology, Ewha Womans University Mokdong Hospital, Ewha Womans University School of Medicine, Seoul (Korea, Republic of); Cha, Joo Hee; Kim, Nam Kug; Chang, Young Jun; Kim, Hak Hee [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Ko, Myung Su [Health Screening and Promotion Center, Asan Medical Center, Seoul (Korea, Republic of); Choi, Young Wook [Korea Electrotechnology Research Institute, Ansan (Korea, Republic of)

    2014-04-15

    The aim of this study was to evaluate the performance of a proposed computer-aided detection (CAD) system in automated breast ultrasonography (ABUS). Eighty-nine two-dimensional images (20 cysts, 42 benign lesions, and 27 malignant lesions) were obtained from 47 patients who underwent ABUS (ACUSON S2000). After boundary detection and removal, we detected mass candidates by using the proposed adjusted Otsu's threshold; the threshold was adaptive to the variations of pixel intensities in an image. Then, the detected candidates were segmented. Features of the segmented objects were extracted and used for training/testing in the classification. In our study, a support vector machine classifier was adopted. Eighteen features were used to determine whether the candidates were true lesions or not. A five-fold cross validation was repeated 20 times for the performance evaluation. The sensitivity and the false positive rate per image were calculated, and the classification accuracy was evaluated for each feature. In the classification step, the sensitivity of the proposed CAD system was 82.67% (SD, 0.02%). The false positive rate was 0.26 per image. In the detection/segmentation step, the sensitivities for benign and malignant mass detection were 90.47% (38/42) and 92.59% (25/27), respectively. In the five-fold cross-validation, the standard deviation of pixel intensities for the mass candidates was the most frequently selected feature, followed by the vertical position of the centroids. In the univariate analysis, each feature had 50% or higher accuracy. The proposed CAD system can be used for lesion detection in ABUS and may be useful in improving the screening efficiency.

  18. Orbitrap mass analyser for in situ characterisation of planetary environments: Performance evaluation of a laboratory prototype

    Science.gov (United States)

    Briois, Christelle; Thissen, Roland; Thirkell, Laurent; Aradj, Kenzi; Bouabdellah, Abdel; Boukrara, Amirouche; Carrasco, Nathalie; Chalumeau, Gilles; Chapelon, Olivier; Colin, Fabrice; Coll, Patrice; Cottin, Hervé; Engrand, Cécile; Grand, Noel; Lebreton, Jean-Pierre; Orthous-Daunay, François-Régis; Pennanech, Cyril; Szopa, Cyril; Vuitton, Véronique; Zapf, Pascal; Makarov, Alexander

    2016-10-01

    For decades of space exploration, mass spectrometry has proven to be a reliable instrumentation for the characterisation of the nature and energy of ionic and neutral, atomic and molecular species in the interplanetary medium and upper planetary atmospheres. It has been used as well to analyse the chemical composition of planetary and small bodies environments. The chemical complexity of these environments calls for the need to develop a new generation of mass spectrometers with significantly increased mass resolving power. The recently developed OrbitrapTM mass analyser at ultra-high resolution shows promising adaptability to space instrumentation, offering improved performances for in situ measurements. In this article, we report on our project named ;Cosmorbitrap; aiming at demonstrating the adaptability of the Orbitrap technology for in situ space exploration. We present the prototype that was developed in the laboratory for demonstration of both technical feasibility and analytical capabilities. A set of samples containing elements with masses ranging from 9 to 208 u has been used to evaluate the performance of the analyser, in terms of mass resolving power (reaching 474,000 at m/z 9) and ability to discriminate between isobaric interferences, accuracy of mass measurement (below 15 ppm) and determination of relative isotopic abundances (below 5%) of various samples. We observe a good agreement between the results obtained with the prototype and those of a commercial instrument. As the background pressure is a key parameter for in situ exploration of atmosphere planetary bodies, we study the effect of background gas on the performance of the Cosmorbitrap prototype, showing an upper limit for N2 in our set-up at 10-8 mbar. The results demonstrate the strong potential to adapt this technology to space exploration.

  19. Quark mass anomalous dimension from the twisted mass Dirac operator spectrum

    Energy Technology Data Exchange (ETDEWEB)

    Cichy, Krzysztof [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany). John von Neumann-Inst. fuer Computing NIC; Poznan Univ. (Poland). Faculty of Physics

    2013-12-15

    We investigate whether it is possible to extract the quark mass anomalous dimension and its scale dependence from the spectrum of the twisted mass Dirac operator in Lattice QCD. The answer to this question appears to be positive, provided that one goes to large enough eigenvalues, sufficiently above the non-perturbative regime. The obtained results are compared to continuum perturbation theory. By analyzing possible sources of systematic effects, we find the domain of applicability of the approach, extending from an energy scale of around 1.5 to 4 GeV. The lower limit is dictated by physics (non-perturbative effects at low energies), while the upper bound is set by the ultraviolet cut-off of present-day lattice simulations. We use gauge field configuration ensembles generated by the European Twisted Mass Collaboration (ETMC) with 2 flavours of dynamical twisted mass quarks, at 4 lattice spacings in the range between around 0.04 and 0.08 fm.

  20. Quark mass anomalous dimension from the twisted mass Dirac operator spectrum

    International Nuclear Information System (INIS)

    Cichy, Krzysztof; Poznan Univ.

    2013-12-01

    We investigate whether it is possible to extract the quark mass anomalous dimension and its scale dependence from the spectrum of the twisted mass Dirac operator in Lattice QCD. The answer to this question appears to be positive, provided that one goes to large enough eigenvalues, sufficiently above the non-perturbative regime. The obtained results are compared to continuum perturbation theory. By analyzing possible sources of systematic effects, we find the domain of applicability of the approach, extending from an energy scale of around 1.5 to 4 GeV. The lower limit is dictated by physics (non-perturbative effects at low energies), while the upper bound is set by the ultraviolet cut-off of present-day lattice simulations. We use gauge field configuration ensembles generated by the European Twisted Mass Collaboration (ETMC) with 2 flavours of dynamical twisted mass quarks, at 4 lattice spacings in the range between around 0.04 and 0.08 fm.

  1. The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis

    Directory of Open Access Journals (Sweden)

    Fatma Demet Ä°nce

    2016-08-01

    Full Text Available Objectives: Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. Design and methods: 209 urine samples were analyzed by the Iris iQ200 ELITE (Ä°ris Diagnostics, USA, Dirui FUS-200 (DIRUI Industrial Co., China automatic urine sediment analyzers and by manual microscopic examination. The degree of concordance (Kappa coefficient and the rates within the same grading were evaluated. Results: For erythrocytes, leukocytes, epithelial cells, bacteria, crystals and yeasts, the degree of concordance between the two instruments was better than the degree of concordance between the manual microscopic method and the individual devices. There was no concordance between all methods for casts. Conclusion: The results from the automated analyzers for erythrocytes, leukocytes and epithelial cells were similar to the result of microscopic examination. However, in order to avoid any error or uncertainty, some images (particularly: dysmorphic cells, bacteria, yeasts, casts and crystals have to be analyzed by manual microscopic examination by trained staff. Therefore, the software programs which are used in automatic urine sediment analysers need further development to recognize urinary shaped elements more accurately. Automated systems are important in terms of time saving and standardization. Keywords: Urinalysis, Autoanalysis, Microscopy

  2. Evaluation of Aerosol Mixing State Classes in the GISS Modele-matrix Climate Model Using Single-particle Mass Spectrometry Measurements

    Science.gov (United States)

    Bauer, Susanne E.; Ault, Andrew; Prather, Kimberly A.

    2013-01-01

    Aerosol particles in the atmosphere are composed of multiple chemical species. The aerosol mixing state, which describes how chemical species are mixed at the single-particle level, provides critical information on microphysical characteristics that determine the interaction of aerosols with the climate system. The evaluation of mixing state has become the next challenge. This study uses aerosol time-of-flight mass spectrometry (ATOFMS) data and compares the results to those of the Goddard Institute for Space Studies modelE-MATRIX (Multiconfiguration Aerosol TRacker of mIXing state) model, a global climate model that includes a detailed aerosol microphysical scheme. We use data from field campaigns that examine a variety of air mass regimens (urban, rural, and maritime). At all locations, polluted areas in California (Riverside, La Jolla, and Long Beach), a remote location in the Sierra Nevada Mountains (Sugar Pine) and observations from Jeju (South Korea), the majority of aerosol species are internally mixed. Coarse aerosol particles, those above 1 micron, are typically aged, such as coated dust or reacted sea-salt particles. Particles below 1 micron contain large fractions of organic material, internally-mixed with sulfate and black carbon, and few external mixtures. We conclude that observations taken over multiple weeks characterize typical air mass types at a given location well; however, due to the instrumentation, we could not evaluate mass budgets. These results represent the first detailed comparison of single-particle mixing states in a global climate model with real-time single-particle mass spectrometry data, an important step in improving the representation of mixing state in global climate models.

  3. Mass spectra features of biomass burning boiler and coal burning boiler emitted particles by single particle aerosol mass spectrometer.

    Science.gov (United States)

    Xu, Jiao; Li, Mei; Shi, Guoliang; Wang, Haiting; Ma, Xian; Wu, Jianhui; Shi, Xurong; Feng, Yinchang

    2017-11-15

    In this study, single particle mass spectra signatures of both coal burning boiler and biomass burning boiler emitted particles were studied. Particle samples were suspended in clean Resuspension Chamber, and analyzed by ELPI and SPAMS simultaneously. The size distribution of BBB (biomass burning boiler sample) and CBB (coal burning boiler sample) are different, as BBB peaks at smaller size, and CBB peaks at larger size. Mass spectra signatures of two samples were studied by analyzing the average mass spectrum of each particle cluster extracted by ART-2a in different size ranges. In conclusion, BBB sample mostly consists of OC and EC containing particles, and a small fraction of K-rich particles in the size range of 0.2-0.5μm. In 0.5-1.0μm, BBB sample consists of EC, OC, K-rich and Al_Silicate containing particles; CBB sample consists of EC, ECOC containing particles, while Al_Silicate (including Al_Ca_Ti_Silicate, Al_Ti_Silicate, Al_Silicate) containing particles got higher fractions as size increase. The similarity of single particle mass spectrum signatures between two samples were studied by analyzing the dot product, results indicated that part of the single particle mass spectra of two samples in the same size range are similar, which bring challenge to the future source apportionment activity by using single particle aerosol mass spectrometer. Results of this study will provide physicochemical information of important sources which contribute to particle pollution, and will support source apportionment activities. Copyright © 2017. Published by Elsevier B.V.

  4. From Engineer-To-Order to Mass Customization

    DEFF Research Database (Denmark)

    Haug, Anders; Ladeby, Klaes Rohde; Edwards, Kasper

    2009-01-01

    customization. Second, the individual transitions from mass production and ETO to mass customization are analyzed by: relating the transition to classifications from relevant literature; describing the motivations and risks associated with the transition; and defining some of the most important transition......Purpose - Most mass customization literature focuses on the move from mass production to mass customization. However, in some literature engineer-to-order (ETO) companies are also claiming to have become mass customizers, although it can be questioned if these companies conform to popular...... definitions of mass customizers. The purpose of this paper is to ask the question: under which conditions is it reasonable to label ETO companies as mass customizers? Design/methodology/approach - First, definitions of mass customization are examined and related to ETO companies that move towards mass...

  5. The comparison of automated urine analyzers with manual microscopic examination for urinalysis automated urine analyzers and manual urinalysis

    OpenAIRE

    ?nce, Fatma Demet; Ellida?, Hamit Ya?ar; Koseo?lu, Mehmet; ?im?ek, Ne?e; Yal??n, H?lya; Zengin, Mustafa Osman

    2016-01-01

    Objectives: Urinalysis is one of the most commonly performed tests in the clinical laboratory. However, manual microscopic sediment examination is labor-intensive, time-consuming, and lacks standardization in high-volume laboratories. In this study, the concordance of analyses between manual microscopic examination and two different automatic urine sediment analyzers has been evaluated. Design and methods: 209 urine samples were analyzed by the Iris iQ200 ELITE (Ä°ris Diagnostics, USA), Dirui...

  6. Hierarchical cluster analysis of technical replicates to identify interferents in untargeted mass spectrometry metabolomics.

    Science.gov (United States)

    Caesar, Lindsay K; Kvalheim, Olav M; Cech, Nadja B

    2018-08-27

    Mass spectral data sets often contain experimental artefacts, and data filtering prior to statistical analysis is crucial to extract reliable information. This is particularly true in untargeted metabolomics analyses, where the analyte(s) of interest are not known a priori. It is often assumed that chemical interferents (i.e. solvent contaminants such as plasticizers) are consistent across samples, and can be removed by background subtraction from blank injections. On the contrary, it is shown here that chemical contaminants may vary in abundance across each injection, potentially leading to their misidentification as relevant sample components. With this metabolomics study, we demonstrate the effectiveness of hierarchical cluster analysis (HCA) of replicate injections (technical replicates) as a methodology to identify chemical interferents and reduce their contaminating contribution to metabolomics models. Pools of metabolites with varying complexity were prepared from the botanical Angelica keiskei Koidzumi and spiked with known metabolites. Each set of pools was analyzed in triplicate and at multiple concentrations using ultraperformance liquid chromatography coupled to mass spectrometry (UPLC-MS). Before filtering, HCA failed to cluster replicates in the data sets. To identify contaminant peaks, we developed a filtering process that evaluated the relative peak area variance of each variable within triplicate injections. These interferent peaks were found across all samples, but did not show consistent peak area from injection to injection, even when evaluating the same chemical sample. This filtering process identified 128 ions that appear to originate from the UPLC-MS system. Data sets collected for a high number of pools with comparatively simple chemical composition were highly influenced by these chemical interferents, as were samples that were analyzed at a low concentration. When chemical interferent masses were removed, technical replicates clustered in

  7. A model for evaluating beef cattle rations considering effects of ruminal fiber mass

    Directory of Open Access Journals (Sweden)

    Douglas Sampaio Henrique

    2011-11-01

    Full Text Available A mathematical model based on Cornell Net Carbohydrate and Protein System (CNCPS was developed and adapted in order to evaluate beef cattle rations at tropical climate conditions. The presented system differs from CNCPS in the modeling of insoluble particles' digestion and passage kinetics, which enabled the estimation of fiber mass in rumen and its effects on animal performance. The equations used to estimate metabolizable protein and net energy requirements for gain, net energy requirement for maintenance and total efficiency of metabolizable energy utilization were obtained from scientific articles published in Brazil. The parameters of the regression equations in these papers were estimated using data from Bos indicus purebred and crossbred animals reared under tropical conditions. The model was evaluated by using a 368-piece of information database originally published on 11 Doctoral theses, 14 Master's dissertations and four scientific articles. Outputs of the model can be considered adequate.

  8. $K^{0}-\\overline{K}^{0}$ mass and decay-width differences CPLEAR evaluation

    CERN Document Server

    Angelopoulos, Angelos; Aslanides, Elie; Backenstoss, Gerhard; Bargassa, P; Behnke, O; Benelli, A; Bertin, V; Blanc, F; Bloch, P; Carlson, P J; Carroll, M; Cawley, E; Chertok, M B; Danielsson, M; Dejardin, M; Derré, J; Ealet, A; Eleftheriadis, C; Fetscher, W; Fidecaro, Maria; Filipcic, A; Francis, D; Fry, J; Gabathuler, Erwin; Gamet, R; Gerber, H J; Go, A; Haselden, A; Hayman, P J; Henry-Coüannier, F; Hollander, R W; Jon-And, K; Kettle, P R; Kokkas, P; Kreuger, R; Le Gac, R; Leimgruber, F; Mandic, I; Manthos, N; Marel, Gérard; Mikuz, M; Miller, J; Montanet, François; Müller, A; Nakada, Tatsuya; Pagels, B; Papadopoulos, I M; Pavlopoulos, P; Polivka, G; Rickenbach, R; Roberts, B L; Ruf, T; Schäfer, M; Schaller, L A; Schietinger, T; Schopper, A; Tauscher, Ludwig; Thibault, C; Touchard, F; Touramanis, C; van Eijk, C W E; Vlachos, S; Weber, P; Wigger, O; Wolter, M; Zavrtanik, D; Zimmerman, D

    1999-01-01

    The CPT-violation parameters \\redd\\ and \\imd\\ determined recently by CPLEAR are used to evaluate the \\kn --\\knb\\ mass and decay-width differences, as given by the difference between the diagonal elements of the neutral-kaon mixing matrix $({\\mathrm M}-\\i\\Gamma/2)$. The results --- $({\\mathrm M}_{\\kn\\kn}-{\\mathrm M}_{\\knb\\knb}) = ( -1.5 \\pm 2.0 )\\times10^{-18}$ \\gev\\ and $(\\Gamma_{\\kn\\kn}-\\Gamma_{\\knb\\knb}) = ( 3.9 \\pm 4.2 )\\times 10^{-18}$ \\gev\\ --- are consistent with CPT invariance. The CPT invariance is also shown to hold within a few times $10^{-3}-10^{-4}$ for many of the amplitudes describing neutral-kaon decays to different final states.

  9. A way toward analyzing high-content bioimage data by means of semantic annotation and visual data mining

    Science.gov (United States)

    Herold, Julia; Abouna, Sylvie; Zhou, Luxian; Pelengaris, Stella; Epstein, David B. A.; Khan, Michael; Nattkemper, Tim W.

    2009-02-01

    In the last years, bioimaging has turned from qualitative measurements towards a high-throughput and highcontent modality, providing multiple variables for each biological sample analyzed. We present a system which combines machine learning based semantic image annotation and visual data mining to analyze such new multivariate bioimage data. Machine learning is employed for automatic semantic annotation of regions of interest. The annotation is the prerequisite for a biological object-oriented exploration of the feature space derived from the image variables. With the aid of visual data mining, the obtained data can be explored simultaneously in the image as well as in the feature domain. Especially when little is known of the underlying data, for example in the case of exploring the effects of a drug treatment, visual data mining can greatly aid the process of data evaluation. We demonstrate how our system is used for image evaluation to obtain information relevant to diabetes study and screening of new anti-diabetes treatments. Cells of the Islet of Langerhans and whole pancreas in pancreas tissue samples are annotated and object specific molecular features are extracted from aligned multichannel fluorescence images. These are interactively evaluated for cell type classification in order to determine the cell number and mass. Only few parameters need to be specified which makes it usable also for non computer experts and allows for high-throughput analysis.

  10. Dirac or Majorana nature and mass effects on the neutrino behaviour; Effets de la nature de Dirac ou de Majorana, ainsi que de la masse, sur le comportement du neutrino

    Energy Technology Data Exchange (ETDEWEB)

    Campagne, J E

    1995-04-01

    This work deals with the Dirac or Majorana nature and mass effects on the neutrino behaviour. In the first part of this study are given the Dirac equation properties and the Majorana neutrino definition. As the difference between a Dirac and a Majorana neutrino has only a sense if their masses are not equal to zero, the second part presents a generalization of the Dirac mass term and the different ways to generate a neutrino mass. Several comparisons are made in the third part between quarks and leptons families mixtures which are linked intimately to masses generation. The fourth part gives an example of masses possible values and neutrinos particles mixtures matrix elements predicting. The neutrino electromagnetic and weak interactions are then considered as well as the neutrinos production by the neutral currents. The charged currents are however better to discriminate the Dirac or Majorana nature. The neutrinos propagation in the matter and in the vacuum are analyzed (the case of neutrino oscillations more particularly) under the result of recent experimental observations. At last, are presented the evaluation of neutrino mass (if it exists) through the analysis of double beta decay and the sensibility of future experiments. (O.L.). 164 refs., 73 figs., 20 tabs.

  11. Quantitative evaluation of small breast masses using a compartment model analysis on dynamic MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Osamu; Morishita, Shoji; Kido, Taeko; Kitajima, Mika; Okamura, Kenji; Fukuda, Seiji [Kumamoto Rosai Hospital, Yatsushiro (Japan); Yamashita, Yasuyuki; Takahashi, Mutsumasa

    1998-07-01

    To differentiate between malignant and benign breast masses using a compartmental analysis, 55 patients with breast masses (fibroadenoma, n=22; invasive ductal carcinoma, n=29; noninvasive ductal carcinoma, n=8) underwent Gd-DTPA enhanced dynamic MR imaging. Dynamic MR images obtained using two-dimensional fat-saturated fast multiplanar corrupted gradient echo technique over 10 minutes following bolus injection of Gd-DTPA. The triexponential concentration curve of Gd-DTPA was fitted to a theoretical model based on compartmental analysis. Using this method, the transfer constant (or permeability surface product per unit volume of component k) and f{sub 3}/f{sub 1}=f were measured, where f{sub 1} represents tumor vessel volume and f{sub 3} represents extracellular volume. The k value was significantly greater (p<0.01) for malignant tumors, and the k value seen in cases of noninvasive ductal carcinoma was less than that for invasive ductal carcinoma. The f value was significantly smaller (p<0.01) for malignant tumors, whereas the f value for noninvasive ductal carcinoma was not significantly different from that for invasive ductal carcinoma. We believe that this type of compartmental analysis may be of value for the evaluation of breast masses. (author)

  12. Trajectories of bright stars at the Galactic Center as a tool to evaluate a graviton mass

    Directory of Open Access Journals (Sweden)

    Zakharov Alexander

    2016-01-01

    Full Text Available Scientists worked in Saint-Petersburg (Petrograd, Leningrad played the extremely important role in creation of scientific school and development of general relativity in Russia. Very recently LIGO collaboration discovered gravitational waves [1] predicted 100 years ago by A. Einstein. In the papers reporting about this discovery, the joint LIGO & VIRGO team presented an upper limit on graviton mass such as mg < 1.2 × 10−22eV [1, 2]. The authors concluded that their observational data do not show violations of classical general relativity because the graviton mass limit is very small. We show that an analysis of bright star trajectories could bound graviton mass with a comparable accuracy with accuracies reached with gravitational wave interferometers and expected with forthcoming pulsar timing observations for gravitational wave detection. This analysis gives an opportunity to treat observations of bright stars near the Galactic Center as a tool for an evaluation specific parameters of the black hole and also to obtain constraints on the fundamental gravity law such as a modifications of Newton gravity law in a weak field approximation. In that way, based on a potential reconstruction at the Galactic Center we give a bounds on a graviton mass.

  13. The role of lean body mass and physical activity in bone health in children.

    Science.gov (United States)

    Baptista, Fátima; Barrigas, Carlos; Vieira, Filomena; Santa-Clara, Helena; Homens, Pedro Mil; Fragoso, Isabel; Teixeira, Pedro J; Sardinha, Luís B

    2012-01-01

    In the context of physical education curricula, markers of physical fitness (e.g., aerobic capacity, muscular strength, flexibility, and body mass index or body fat) are usually evaluated in reference to health standards. Despite their possible mediating role in the relationship between weight-bearing or muscle forces and features of bone tissue, these attributes of fitness may not be the most relevant to predict skeletal health. It is therefore important to analyze the relative contribution of these factors to the variability in bone tissue of different parts of the skeleton, and to analyze it by gender, as sensitivity to mechanical loading can diverge for boys and girls. We compared the effects of habitual physical activity (PA) and lean mass, as surrogates of weight-bearing and muscle forces, and of physical fitness (aerobic and muscle capacity of lower and upper limbs) on bone mineral content (BMC) and size of total body, lumbar spine, femoral neck, and 1/3 radius in 53 girls and 64 boys from 7.9 to 9.7 years of age. After controlling for bone age, body mass, body height, and calcium intake, lean mass was the most important predictor of bone size and/or mineral in both genders (p  608 counts/min/day (~105 min/day of moderate and vigorous intensity) showed 13-20% more BMC than those with less physical activity, and girls with a lean mass >19 kg showed 12-19% more BMC than those with less lean mass. These findings suggest that lean mass was the most important predictor of bone size and/or mineralization in both genders, while habitual weight-bearing PA appears to positively impact on bone mineral in prepubertal boys and that both lean mass and PA need to be considered in physical education curricula and other health-enhancing programs.

  14. Development and evaluation of a workpiece temperature analyzer (WPTA) for industrial furances (Phase 1)

    Energy Technology Data Exchange (ETDEWEB)

    1991-10-01

    This project is directed toward the research, development, and evaluation of a viable commercial product-a workpiece temperature measurement analyzer (WPTA) for fired furnaces based on unique radiation properties of surfaces. This WPTA will provide for more uniform, higher quality products and reduce product rejects as well as permit the optimum use of energy. The WPTA may also be utilized in control system applications including metal heat treating, forging furnaces, and ceramic firing furnaces. A large market also exists in the chemical process and refining industry. WPTA applications include the verification of product temperature/time cycles, and use as a front-end sensor for automatic feedback control systems. This report summarizes the work performed in Phase 1 of this three-phase project. The work Phase 1 included the application evaluation; the evaluation of present technologies and limitations; and the development of a preliminary conceptual WPTA design, including identification of technical and economic benefits. Recommendations based on the findings of this report include near-term enhancement of the capabilities of the Pyrolaser, and long-term development of an instrument based on Raman Spectroscopy. Development of the Pyrofiber, fiberoptics version of the Pyrolaser, will be a key to solving present problems involving specularity, measurement angle, and costs of multipoint measurement. Extending the instrument's measurement range to include temperatures below 600{degrees}C will make the product useful for a wider range of applications. The development of Raman Spectroscopy would result in an instrument that could easily be adapted to incorporate a wealth of additional nondestructive analytical capabilities, including stress/stain indication, crystallography, species concentrations, corrosion studies, and catalysis studies, in addition to temperature measurement. 9 refs., 20 figs., 16 tabs.

  15. Improved mammographic interpretation of masses using computer-aided diagnosis

    International Nuclear Information System (INIS)

    Leichter, I.; Fields, S.; Novak, B.; Nirel, R.; Bamberger, P.; Lederman, R.; Buchbinder, S.

    2000-01-01

    The aim of this study was to evaluate the effectiveness of computerized image enhancement, to investigate criteria for discriminating benign from malignant mammographic findings by computer-aided diagnosis (CAD), and to test the role of quantitative analysis in improving the accuracy of interpretation of mass lesions. Forty sequential mammographically detected mass lesions referred for biopsy were digitized at high resolution for computerized evaluation. A prototype CAD system which included image enhancement algorithms was used for a better visualization of the lesions. Quantitative features which characterize the spiculation were automatically extracted by the CAD system for a user-defined region of interest (ROI). Reference ranges for malignant and benign cases were acquired from data generated by 214 known retrospective cases. The extracted parameters together with the reference ranges were presented to the radiologist for the analysis of 40 prospective cases. A pattern recognition scheme based on discriminant analysis was trained on the 214 retrospective cases, and applied to the prospective cases. Accuracy of interpretation with and without the CAD system, as well as the performance of the pattern recognition scheme, were analyzed using receiver operating characteristics (ROC) curves. A significant difference (p z ) increased significantly (p z for the results of the pattern recognition scheme was higher (0.95). The results indicate that there is an improved accuracy of diagnosis with the use of the mammographic CAD system above that of the unassisted radiologist. Our findings suggest that objective quantitative features extracted from digitized mammographic findings may help in differentiating between benign and malignant masses, and can assist the radiologist in the interpretation of mass lesions. (orig.)

  16. Evaluation of a portable automated serum chemistry analyzer for field assessment of harlequin ducks, Histrionicus histrionicus

    Science.gov (United States)

    Stoskopf, Michael K.; Mulcahy, Daniel M.; Esler, Daniel N.

    2010-01-01

    A portable analytical chemistry analyzer was used to make field assessments of wild harlequin ducks (Histrionicus histrionicus) in association with telemetry studies of winter survival in Prince William Sound, Alaska. We compared serum chemistry results obtained on-site with results from a traditional laboratory. Particular attention was paid to serum glucose and potassium concentrations as potential indicators of high-risk surgical candidates based on evaluation of the field data. The median differential for glucose values ( = 8 2) between methods was 0.6 mmol/L (quartiles 0.3 and 0.9 mmol/L) with the median value higher when assayed on site. Analysis of potassium on site returned a median of 2.7 mmol/L ( = 8 8 ; quartiles 2.4 and 3.0 mmol/L). Serum potassium values were too low for quantitation by the traditional laboratory. Changes in several serum chemistry values following a three-day storm during the study support the value of on site evaluation of serum potassium to identify presurgical patients with increased anesthetic risk.

  17. Use of the TFTR prototype charge exchange neutral analyzer for fast He3++ diagnostics during ICRF heating on PLT

    International Nuclear Information System (INIS)

    Medley, S.S.

    1981-07-01

    The Charge Exchange Neutral Analyzer (CENA) for TFTR is designed to measure singly charged ion species of atomic mass A = 1, 2, and 3 simultaneously with up to 75 energy channels per mass and an energy range of 0.5 3 charge exchange neutrals makes the analyzer of particular interest for recently proposed fast He 3 ++ diagnostics during ICRF heating on PLT

  18. Evaluation of lead isotope compositions of NIST NBS 981 measured by thermal ionization mass spectrometer and multiple-collector inductively coupled plasma mass spectrometer

    Directory of Open Access Journals (Sweden)

    Honglin Yuan

    2016-09-01

    Full Text Available Because Pb isotopes can be used for tracing, they are widely used in many disciplines. The detection and analysis of Pb isotopes of bulk samples are usually conducted using thermal ionization mass spectrometer (TIMS and multiple-collector inductively coupled plasma mass spectrometer (MC-ICP-MS, both of which need external reference materials with known isotopic compositions to correct for the mass discrimination effect produced during analysis. NIST NBS 981 is the most widely used reference material for Pb isotope analysis; however, the isotopic compositions reported by various analytical laboratories, especially those using TIMS, vary from each other. In this study, we statistically evaluated 229 reported TIMS analysis values collected by GeoReM in the last 30 years, 176 reported MC-ICP-MS analysis values, and 938 MC-ICP-MS analysis results from our laboratory in the last five years. After careful investigation, only 40 TIMS results were found to have double or triple spikes. The ratios of the overall weighted averages, 206Pb/204Pb, 207Pb/204Pb, and 208Pb/204Pb, obtained from 40 spiked TIMS reports and 1114 MC-ICP-MS results of NIST NBS 981 isotopes were 16.9406 ± 0.0003 (2s, 15.4957 ± 0.0002 (2s, and 36.7184 ± 0.0007 (2s, respectively.

  19. Measuring and Analyzing the Scholarly Impact of Experimental Evaluation Initiatives

    DEFF Research Database (Denmark)

    Angelini, Marco; Ferro, Nicola; Larsen, Birger

    2014-01-01

    Evaluation initiatives have been widely credited with contributing highly to the development and advancement of information access systems, by providing a sustainable platform for conducting the very demanding activity of comparable experimental evaluation in a large scale. Measuring the impact...

  20. Time-reversal asymmetry: polarization and analyzing power in nuclear reactions

    International Nuclear Information System (INIS)

    Rioux, C.; Roy, R.; Slobodrian, R.J.; Conzett, H.E.

    1984-01-01

    Measurements of the proton polarization in the reactions 7 Li( 3 He, p vector) 9 Be and 9 Be( 3 He, p vector) 11 B and of the analyzing powers in the inverse reactions, initiated by polarized protons at the same center-of-mass energies, show significant differences. This implies the failure of the polarization-analyzing-power theorem and, prima facie, of time-reversal invariance in these reactions. The reaction 2 H( 3 He, p vector) 4 He and its inverse have also been investigated and show smaller differences. A discussion of instrumental asymmetries is presented

  1. Mass transfer and transport in salt repositories

    International Nuclear Information System (INIS)

    Pigford, T.H.; Chambre, P.L.; Lee, W.W.L.

    1989-02-01

    Salt is a unique rock isolation of nuclear waste because it is ''dry'' and nearly impermeable. In this paper we summarize some mass-transfer and transport analyses of salt repositories. First we analyses brine migration. Heating by high-level waste can cause brine in grain boundaries to move due to pressure-gradients. We analyze brine migration treating salt as a thermoelastic solid and found that brine migration is transient and localized. We use previously developed techniques to estimate release rates from waste packages by diffusion. Interbeds exist in salt and may be conduits for radionuclide migration. We analyze steady-state migration due to brine flow in the interbed, as a function of the Peclet number. Then we analyze transient mass transfer, both into the interbed and directly to salt, due only to diffusion. Finally we compare mass transfer rates of a waste cylinder in granite facing a fracture and in salt facing an interbed. In all cases, numerical illustrations of the analytic solution are given. 10 refs., 4 figs., 3 tabs

  2. A Liquid Chromatography-Quadrupole-Time of Flight Mass Spectrometry (LC-Q-TOF MS) Study for Analyzing 35 Corticosteroid Compounds: Elucidation of MS/MS Fragmentation Pathways

    International Nuclear Information System (INIS)

    Noh, Eunyoung; Yoon, Chang-Yong; Lee, Ji Hyun; Baek, Sun-Young; Do, Jung-Ah; Lee, Jung-min; Oh, Han Bin

    2016-01-01

    Corticosteroids have been often found to be added to a dietary supplement for the purpose of illegally improving the effect of their products. Thus, it is imperative to develop or improve a method that enables one to rapidly and reliably analyze corticosteroids in health or dietary supplements, for the safety management purpose. In the present study, results from liquid chromatography-quadrupole time-of-flight mass spectrometry (LC-Q-TOF-MS) experiments for the selected 35 corticosteroid compounds are presented, which can be useful for the qualitative screening of corticosteroids in health or dietary supplements. Specifically, retention times, accurate mass data of the protonated steroids, m/z values of major fragment ions are given for the 35 corticosteroids. Further, fragmentation pathways for the selected steroids are also suggested. Based on the suggested fragmentation pathways, it was shown that an unknown steroid compound can be readily identified using the knowledge of a group of unique and specific common skeletal fragments. The high selectivity and sensitivity of the LC-Q-TOF-MS/MS results combined with the knowledge of the fragmentation pathways can offer a new opportunity for rapid and accurate screening of corticosteroids, thus preventing health-related incidents involving adulterated products and clamping down on illegally circulated health products.

  3. A Liquid Chromatography-Quadrupole-Time of Flight Mass Spectrometry (LC-Q-TOF MS) Study for Analyzing 35 Corticosteroid Compounds: Elucidation of MS/MS Fragmentation Pathways

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Eunyoung; Yoon, Chang-Yong; Lee, Ji Hyun; Baek, Sun-Young; Do, Jung-Ah [Ministry of Food and Drug Safety, Cheongju (Korea, Republic of); Lee, Jung-min; Oh, Han Bin [Sogang University, Seoul (Korea, Republic of)

    2016-07-15

    Corticosteroids have been often found to be added to a dietary supplement for the purpose of illegally improving the effect of their products. Thus, it is imperative to develop or improve a method that enables one to rapidly and reliably analyze corticosteroids in health or dietary supplements, for the safety management purpose. In the present study, results from liquid chromatography-quadrupole time-of-flight mass spectrometry (LC-Q-TOF-MS) experiments for the selected 35 corticosteroid compounds are presented, which can be useful for the qualitative screening of corticosteroids in health or dietary supplements. Specifically, retention times, accurate mass data of the protonated steroids, m/z values of major fragment ions are given for the 35 corticosteroids. Further, fragmentation pathways for the selected steroids are also suggested. Based on the suggested fragmentation pathways, it was shown that an unknown steroid compound can be readily identified using the knowledge of a group of unique and specific common skeletal fragments. The high selectivity and sensitivity of the LC-Q-TOF-MS/MS results combined with the knowledge of the fragmentation pathways can offer a new opportunity for rapid and accurate screening of corticosteroids, thus preventing health-related incidents involving adulterated products and clamping down on illegally circulated health products.

  4. Discussion of the Improved Methods for Analyzing a Cantilever Beam Carrying a Tip-Mass under Base Excitation

    Directory of Open Access Journals (Sweden)

    Wang Hongjin

    2014-01-01

    Full Text Available Two improved analytical methods of calculations for natural frequencies and mode shapes of a uniform cantilever beam carrying a tip-mass under base excitation are presented based on forced vibration theory and the method of separation of variables, respectively. The cantilever model is simplified in detail by replacing the tip-mass with an equivalent inertial force and inertial moment acting at the free end of the cantilever based on D’Alembert’s principle. The concentrated equivalent inertial force and inertial moment are further represented as distributed loads using Dirac Delta Function. In this case, some typical natural frequencies and mode shapes of the cantilever model are calculated by the improved and unimproved analytical methods. The comparing results show that, after improvement, these two methods are in extremely good agreement with each other even the offset distance between the gravity center of the tip-mass and the attachment point is large. As further verification, the transient and steady displacement responses of the cantilever system under a sine base excitation are presented in which two improved methods are separately utilized. Finally, an experimental cantilever system is fabricated and the theoretical displacement responses are validated by the experimental measurements successfully.

  5. MASS-RADIUS RELATIONSHIPS FOR VERY LOW MASS GASEOUS PLANETS

    International Nuclear Information System (INIS)

    Batygin, Konstantin; Stevenson, David J.

    2013-01-01

    Recently, the Kepler spacecraft has detected a sizable aggregate of objects, characterized by giant-planet-like radii and modest levels of stellar irradiation. With the exception of a handful of objects, the physical nature, and specifically the average densities, of these bodies remain unknown. Here, we propose that the detected giant planet radii may partially belong to planets somewhat less massive than Uranus and Neptune. Accordingly, in this work, we seek to identify a physically sound upper limit to planetary radii at low masses and moderate equilibrium temperatures. As a guiding example, we analyze the interior structure of the Neptune-mass planet Kepler-30d and show that it is acutely deficient in heavy elements, especially compared with its solar system counterparts. Subsequently, we perform numerical simulations of planetary thermal evolution and in agreement with previous studies, show that generally, 10-20 M ⊕ , multi-billion year old planets, composed of high density cores and extended H/He envelopes can have radii that firmly reside in the giant planet range. We subject our results to stability criteria based on extreme ultraviolet radiation, as well as Roche-lobe overflow driven mass-loss and construct mass-radius relationships for the considered objects. We conclude by discussing observational avenues that may be used to confirm or repudiate the existence of putative low mass, gas-dominated planets.

  6. Photoelectric equipment type MFS-7 for analyzing oils

    International Nuclear Information System (INIS)

    Orlova, S.A.; Fridman, M.G.; Kholosha, T.V.; Ezhoda, G.D.; Nechitailov, V.V.

    1987-01-01

    The authors describe the equipment type MFS-7 which is intended for analyzing used oils for the wear products of motors. The difference between type MFS-7 and its predecessors lies in the application of computer techniques to control the equipment and process the output data; and in the design of the sample container, which allows for two methods of introducing the sample into the discharge. The photoelectric equipment consists of an excitation spectrum source IVS-28, having an ac arc mode and 1.v. spark, a polychoromator, a special sample holder for analyzing liquid samples, an electronic recording apparatus with digital voltmeter type ERU-18 and control computer system Spectr 2.2 based on a minicomputer with its own printer. The type MFS-7 equipment has been tested and put into mass production

  7. Advancements of in-flight mass moment of inertia and structural deflection algorithms for satellite attitude simulators

    Science.gov (United States)

    Wright, Jonathan W.

    Experimental satellite attitude simulators have long been used to test and analyze control algorithms in order to drive down risk before implementation on an operational satellite. Ideally, the dynamic response of a terrestrial-based experimental satellite attitude simulator would be similar to that of an on-orbit satellite. Unfortunately, gravitational disturbance torques and poorly characterized moments of inertia introduce uncertainty into the system dynamics leading to questionable attitude control algorithm experimental results. This research consists of three distinct, but related contributions to the field of developing robust satellite attitude simulators. In the first part of this research, existing approaches to estimate mass moments and products of inertia are evaluated followed by a proposition and evaluation of a new approach that increases both the accuracy and precision of these estimates using typical on-board satellite sensors. Next, in order to better simulate the micro-torque environment of space, a new approach to mass balancing satellite attitude simulator is presented, experimentally evaluated, and verified. Finally, in the third area of research, we capitalize on the platform improvements to analyze a control moment gyroscope (CMG) singularity avoidance steering law. Several successful experiments were conducted with the CMG array at near-singular configurations. An evaluation process was implemented to verify that the platform remained near the desired test momentum, showing that the first two components of this research were effective in allowing us to conduct singularity avoidance experiments in a representative space-like test environment.

  8. Comparison of ion coupling strategies for a microengineered quadrupole mass filter.

    Science.gov (United States)

    Wright, Steven; Syms, Richard R A; O'Prey, Shane; Hong, Guodong; Holmes, Andrew S

    2009-01-01

    The limitations of conventional machining and assembly techniques require that designs for quadrupole mass analyzers with rod diameters less than a millimeter are not merely scale versions of larger instruments. We show how silicon planar processing techniques and microelectromechanical systems (MEMS) design concepts can be used to incorporate complex features into the construction of a miniature quadrupole mass filter chip that could not easily be achieved using other microengineering approaches. Three designs for the entrance and exit to the filter consistent with the chosen materials and techniques have been evaluated. The differences between these seemingly similar structures have a significant effect on the performance. Although one of the designs results in severe attenuation of transmission with increasing mass, the other two can be scanned to m/z = 400 without any corruption of the mass spectrum. At m/z = 219, the variation in the transmission of the three designs was found to be approximately four orders of magnitude. A maximum resolution of M/DeltaM = 87 at 10% peak height has been achieved at m/z = 219 with a filter operated at 6 MHz and constructed using rods measuring (508 +/- 5) microm in diameter.

  9. Evaluation of the sensitivity of the 'Wiley registry of tandem mass spectral data, MSforID' with MS/MS data of the 'NIST/NIH/EPA mass spectral library'.

    Science.gov (United States)

    Oberacher, Herbert; Whitley, Graeme; Berger, Bernd

    2013-04-01

    Tandem mass spectral libraries are versatile tools for small molecular identification finding application in forensic science, doping control, drug monitoring, food and environmental analysis, as well as metabolomics. Two important libraries are the 'Wiley Registry of Tandem Mass Spectral Data, MSforID' (Wiley Registry MSMS) and the collection of MS/MS spectra part of the 2011 edition of the 'NIST/NIH/EPA Mass Spectral Library' (NIST 11 MSMS). Herein, the sensitivity and robustness of the Wiley Registry MSMS were evaluated using spectra extracted from the NIST 11 MSMS library. The sample set was found to be heterogeneous in terms of mass spectral resolution, type of CID, as well as applied collision energies. Nevertheless, sensitive compound identification with a true positive identification rate ≥95% was possible using either the MSforID Search program or the NIST MS Search program 2.0g for matching. To rate the performance of the Wiley Registry MSMS, cross-validation experiments were repeated using subcollections of NIST 11 MSMS as reference library and spectra extracted from the Wiley Registry MSMS as positive controls. Unexpectedly, with both search algorithms tested, correct results were obtained in less than 88% of cases. We examined possible causes for the results of the cross validation study. The large number of precursor ions represented by a single tandem mass spectrum only was identified as the basic cause for the comparably lower sensitivity of the NIST library. Copyright © 2013 John Wiley & Sons, Ltd.

  10. Practical aspects and trends in analytical organic mass spectrometry

    International Nuclear Information System (INIS)

    Schlunegger, U.P.

    1981-01-01

    Proceeding from the fundamentals of mass spectrometry (MS), some more recent developments of analytical organic MS are shown in comparison with conventional MS. Sections are headed: the vacuum, production of ions in the mass spectrometer, ions in the analyzer of a mass spectrometer, general considerations, practice of modern MS: selected examples

  11. Improved accuracy and precision in δ15 NAIR measurements of explosives, urea, and inorganic nitrates by elemental analyzer/isotope ratio mass spectrometry using thermal decomposition.

    Science.gov (United States)

    Lott, Michael J; Howa, John D; Chesson, Lesley A; Ehleringer, James R

    2015-08-15

    Elemental analyzer systems generate N(2) and CO(2) for elemental composition and isotope ratio measurements. As quantitative conversion of nitrogen in some materials (i.e., nitrate salts and nitro-organic compounds) is difficult, this study tests a recently published method - thermal decomposition without the addition of O(2) - for the analysis of these materials. Elemental analyzer/isotope ratio mass spectrometry (EA/IRMS) was used to compare the traditional combustion method (CM) and the thermal decomposition method (TDM), where additional O(2) is eliminated from the reaction. The comparisons used organic and inorganic materials with oxidized and/or reduced nitrogen and included ureas, nitrate salts, ammonium sulfate, nitro esters, and nitramines. Previous TDM applications were limited to nitrate salts and ammonium sulfate. The measurement precision and accuracy were compared to determine the effectiveness of converting materials containing different fractions of oxidized nitrogen into N(2). The δ(13) C(VPDB) values were not meaningfully different when measured via CM or TDM, allowing for the analysis of multiple elements in one sample. For materials containing oxidized nitrogen, (15) N measurements made using thermal decomposition were more precise than those made using combustion. The precision was similar between the methods for materials containing reduced nitrogen. The %N values were closer to theoretical when measured by TDM than by CM. The δ(15) N(AIR) values of purchased nitrate salts and ureas were nearer to the known values when analyzed using thermal decomposition than using combustion. The thermal decomposition method addresses insufficient recovery of nitrogen during elemental analysis in a variety of organic and inorganic materials. Its implementation requires relatively few changes to the elemental analyzer. Using TDM, it is possible to directly calibrate certain organic materials to international nitrate isotope reference materials without off

  12. Mass and Charge Measurements on Heavy Ions

    Science.gov (United States)

    Sugai, Toshiki

    2017-01-01

    The relationship between mass and charge has been a crucial topic in mass spectrometry (MS) because the mass itself is typically evaluated based on the m/z ratio. Despite the fact that this measurement is indirect, a precise mass can be obtained from the m/z value with a high m/z resolution up to 105 for samples in the low mass and low charge region under 10,000 Da and 20 e, respectively. However, the target of MS has recently been expanded to the very heavy region of Mega or Giga Da, which includes large particles and biocomplexes, with very large and widely distributed charge from kilo to Mega range. In this region, it is necessary to evaluate charge and mass simultaneously. Recent studies for simultaneous mass and charge observation and related phenomena are discussed in this review. PMID:29302406

  13. Light baryon masses with dynamical twisted mass fermions

    International Nuclear Information System (INIS)

    Alexandrou, C.; Korzec, T.; Koutsou, G.; Baron, R.; Guichon, P.; Blossier, B.; Herdoiza, G.; Jansen, K.; Brinet, M.; Carbonell, J.; Drach, V.; Dimopoulos, P.; Frezzotti, R.; Farchioni, F.; Liu, Z.; Pene, O.; Michael, C.; Shindler, A.; Urbach, C.; Wenger, U.

    2008-01-01

    We present results on the mass of the nucleon and the Δ using two dynamical degenerate twisted mass quarks and the tree-level Symanzik improved gauge action. The evaluation is performed at four quark masses corresponding to a pion mass in the range of about 300-600 MeV on lattices of 2.1-2.7 fm at three lattice spacings less than 0.1 fm. We check for cutoff effects by evaluating these baryon masses on lattices of spatial size 2.1 fm at β=3.9 and β=4.05 and on a lattice of 2.4 fm at β=3.8. The values we find are compatible within our statistical errors. Lattice results are extrapolated to the physical limit using continuum chiral perturbation theory. Performing a combined fit to our lattice data at β=3.9 and β=4.05 we find a nucleon mass of 963±12(stat)±8(syst) MeV where we used the lattice spacings determined from the pion decay constant to convert to physical units. The systematic error due to the chiral extrapolation is estimated by comparing results obtained at O(p 3 ) and O(p 4 ) heavy baryon chiral perturbation theory. The nucleon mass at the physical point provides an independent determination of the lattice spacing. Using heavy baryon chiral perturbation theory at O(p 3 ) we find a β=3.9 =0.0889±0.0012(stat)±0.0014(syst) fm, and a β=4.05 =0.0691±0.0010(stat)±0.0010(syst) fm, in good agreement with the values determined from the pion decay constant. Using results from our two smaller lattices spacings at constant r 0 m π we estimate the continuum limit and check consistency with results from the coarser lattice. Results at the continuum limit are chirally extrapolated to the physical point. Isospin violating lattice artifacts in the Δ-system are found to be compatible with zero for the values of the lattice spacings used in this work. Performing a combined fit to our lattice data at β=3.9 and β=4.05 we find for the masses of the Δ ++,- and Δ +,0 1315±24(stat) MeV and 1329±30(stat) MeV, respectively. We confirm that in the continuum limit

  14. The Application of Resonance-Enhanced Multiphoton Ionization Technique in Gas Chromatography Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Adan Li

    2014-01-01

    Full Text Available Gas chromatography resonance-enhanced multiphoton ionization time-of-flight mass spectrometry (GC/REMPI-TOFMS using a nanosecond laser has been applied to analyze the 16 polycyclic aromatic hydrocarbons (PAHs. The excited-state lifetime, absorption characters, and energy of electronic states of the 16 PAHs were investigated to optimize the ionization yield. A river water sample pretreated by means of solid phase extraction was analyzed to evaluate the performance of the analytical instrument. The results suggested that REMPI is superior to electron impact ionization method for soft ionization and suppresses the background signal due to aliphatic hydrocarbons. Thus, GC/REMPI-TOFMS is a more reliable method for the determination of PAHs present in the environment.

  15. Hyphenation of a carbon analyzer to photo-ionization mass spectrometry to unravel the organic composition of particulate matter on a molecular level.

    Science.gov (United States)

    Grabowsky, Jana; Streibel, Thorsten; Sklorz, Martin; Chow, Judith C; Watson, John G; Mamakos, Athanasios; Zimmermann, Ralf

    2011-12-01

    The carbonaceous fraction of airborne particulate matter (PM) is of increasing interest due to the adverse health effects they are linked to. Its analytical ascertainment on a molecular level is still challenging. Hence, analysis of carbonaceous fractions is often carried out by determining bulk parameters such as the overall content of organic compounds (OC) and elemental carbon (EC) as well as the total carbon content, TC (sum of OC and EC), however, no information about the individual substances or substance classes, of which the single fractions consist can be obtained. In this work, a carbon analyzer and a photo-ionization time-of-flight mass spectrometer (PI-TOF-MS) were hyphenated to investigate individual compounds especially from the OC fractions. The carbon analyzer enables the stepwise heating of particle samples and provides the bulk parameters. With the PI-TOF-MS, it is possible to detect the organic compounds released during the single-temperature steps due to soft ionization and fast detection of the molecular ions. The hyphenation was designed, built up, characterized by standard substances, and applied to several kinds of samples, such as ambient aerosol, gasoline, and diesel emission as well as wood combustion emission samples. The ambient filter sample showed a strong impact of wood combustion markers. This was revealed by comparison to the product pattern of the similar analysis of pure cellulose and lignin and the wood combustion PM. At higher temperatures (450 °C), a shift to smaller molecules occurred due to the thermal decomposition of larger structures of oligomeric or polymeric nature comparable to lignocelluloses and similar oxygenated humic-like substances. Finally, particulate matter from gasoline and diesel containing 10% biodiesel vehicle exhaust has been analyzed. Gasoline-derived PM exhibited large polycyclic aromatic hydrocarbons, whereas diesel PM showed a much higher total organic content. The detected pattern revealed a strong

  16. Influence of tip mass on dynamic behavior of cracked cantilever pipe conveying fluid with moving mass

    International Nuclear Information System (INIS)

    Yoon, Han Ik; Son, In Soo

    2005-01-01

    In this paper, we studied about the effect of the open crack and a tip mass on the dynamic behavior of a cantilever pipe conveying fluid with a moving mass. The equation of motion is derived by using Lagrange's equation and analyzed by numerical method. The cantilever pipe is modelled by the Euler-Bernoulli beam theory. The crack section is represented by a local flexibility matrix connecting two undamaged pipe segments. The influences of the crack, the moving mass, the tip mass and its moment of inertia, the velocity of fluid, and the coupling of these factors on the vibration mode, the frequency, and the tip-displacement of the cantilever pipe are analytically clarified

  17. Testing the predictive power of nuclear mass models

    International Nuclear Information System (INIS)

    Mendoza-Temis, J.; Morales, I.; Barea, J.; Frank, A.; Hirsch, J.G.; Vieyra, J.C. Lopez; Van Isacker, P.; Velazquez, V.

    2008-01-01

    A number of tests are introduced which probe the ability of nuclear mass models to extrapolate. Three models are analyzed in detail: the liquid drop model, the liquid drop model plus empirical shell corrections and the Duflo-Zuker mass formula. If predicted nuclei are close to the fitted ones, average errors in predicted and fitted masses are similar. However, the challenge of predicting nuclear masses in a region stabilized by shell effects (e.g., the lead region) is far more difficult. The Duflo-Zuker mass formula emerges as a powerful predictive tool

  18. Structural analyses of sucrose laurate regioisomers by mass spectrometry techniques

    DEFF Research Database (Denmark)

    Lie, Aleksander; Stensballe, Allan; Pedersen, Lars Haastrup

    2015-01-01

    6- And 6′-O-lauroyl sucrose were isolated and analyzed by matrix-assisted laser desorption/ionisation (MALDI) time-of-flight (TOF) mass spectrometry (MS), Orbitrap high-resolution (HR) MS, and electrospray-ionization (ESI) tandem mass spectrometry (MS/MS). The analyses aimed to explore the physic......6- And 6′-O-lauroyl sucrose were isolated and analyzed by matrix-assisted laser desorption/ionisation (MALDI) time-of-flight (TOF) mass spectrometry (MS), Orbitrap high-resolution (HR) MS, and electrospray-ionization (ESI) tandem mass spectrometry (MS/MS). The analyses aimed to explore.......8, respectively, and Orbitrap HRMS confirmed the mass of [M+Na]+ (m/z 547.2712). ESI-MS/MS on the precursor ion [M+Na]+ resulted in product ion mass spectra showing two high-intensity signals for each sample. 6-O-Lauroyl sucrose produced signals located at m/z 547.27 and m/z 385.21, corresponding to the 6-O...

  19. One-photon mass-analyzed threshold ionization (MATI) spectroscopy of pyridine: Determination of accurate ionization energy and cationic structure

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yu Ran; Kang, Do Won; Kim, Hong Lae, E-mail: chkwon@kangwon.ac.kr, E-mail: hlkim@kangwon.ac.kr; Kwon, Chan Ho, E-mail: chkwon@kangwon.ac.kr, E-mail: hlkim@kangwon.ac.kr [Department of Chemistry and Institute for Molecular Science and Fusion Technology, College of Natural Sciences, Kangwon National University, Chuncheon 200-701 (Korea, Republic of)

    2014-11-07

    Ionization energies and cationic structures of pyridine were intensively investigated utilizing one-photon mass-analyzed threshold ionization (MATI) spectroscopy with vacuum ultraviolet radiation generated by four-wave difference frequency mixing in Kr. The present one-photon high-resolution MATI spectrum of pyridine demonstrated a much finer and richer vibrational structure than that of the previously reported two-photon MATI spectrum. From the MATI spectrum and photoionization efficiency curve, the accurate ionization energy of the ionic ground state of pyridine was confidently determined to be 73 570 ± 6 cm{sup −1} (9.1215 ± 0.0007 eV). The observed spectrum was almost completely assigned by utilizing Franck-Condon factors and vibrational frequencies calculated through adjustments of the geometrical parameters of cationic pyridine at the B3LYP/cc-pVTZ level. A unique feature unveiled through rigorous analysis was the prominent progression of the 10 vibrational mode, which corresponds to in-plane ring bending, and the combination of other totally symmetric fundamentals with the ring bending overtones, which contribute to the geometrical change upon ionization. Notably, the remaining peaks originate from the upper electronic state ({sup 2}A{sub 2}), as predicted by high-resolution photoelectron spectroscopy studies and symmetry-adapted cluster configuration interaction calculations. Based on the quantitatively good agreement between the experimental and calculated results, it was concluded that upon ionization the pyridine cation in the ground electronic state should have a planar structure of C{sub 2v} symmetry through the C-N axis.

  20. Free neutron-proton analyzing power at medium energies

    International Nuclear Information System (INIS)

    Newsom, C.R.

    1980-01-01

    In recent years, increasing efforts have been made to measure the nucleon-nucleon polarization parameters. To date, no free neutron-proton spin correlated parameters have been published in the energy range 500 to 800 MeV. Existing analyzing power data is of low precision and in most cases was obtained by quasi-free proton scattering. As a first step in determining the neutron-proton scattering matrix, the free neutron-proton analyzing power has been measured at the Los Alamos Physics Facility as a function of energy and angle. The experiment was performed by scattering a neutron beam from a polarized proton target. The neutron beam was generated by scattering 800 MeV protons from a Beryllium target and using the neutrons produced at 0 degrees. The incident energy ranged from 300 MeV to 800 MeV. The energy spread of the neutron beam made it possible to measure the analyzing power at different energies simultaneously. Angular distributions were taken from 60 to 170 degrees in the center of mass system (c.m.)

  1. Improving respiration measurements with gas exchange analyzers.

    Science.gov (United States)

    Montero, R; Ribas-Carbó, M; Del Saz, N F; El Aou-Ouad, H; Berry, J A; Flexas, J; Bota, J

    2016-12-01

    Dark respiration measurements with open-flow gas exchange analyzers are often questioned for their low accuracy as their low values often reach the precision limit of the instrument. Respiration was measured in five species, two hypostomatous (Vitis Vinifera L. and Acanthus mollis) and three amphistomatous, one with similar amount of stomata in both sides (Eucalyptus citriodora) and two with different stomata density (Brassica oleracea and Vicia faba). CO 2 differential (ΔCO 2 ) increased two-fold with no change in apparent R d , when the two leaves with higher stomatal density faced outside. These results showed a clear effect of the position of stomata on ΔCO 2 . Therefore, it can be concluded that leaf position is important to guarantee the improvement of respiration measurements increasing ΔCO 2 without affecting the respiration results by leaf or mass units. This method will help to increase the accuracy of leaf respiration measurements using gas exchange analyzers. Copyright © 2016 Elsevier GmbH. All rights reserved.

  2. Assessment of current mass spectrometric workflows for the quantification of low abundant proteins and phosphorylation sites

    Directory of Open Access Journals (Sweden)

    Manuel Bauer

    2015-12-01

    Full Text Available The data described here provide a systematic performance evaluation of popular data-dependent (DDA and independent (DIA mass spectrometric (MS workflows currently used in quantitative proteomics. We assessed the limits of identification, quantification and detection for each method by analyzing a dilution series of 20 unmodified and 10 phosphorylated synthetic heavy labeled reference peptides, respectively, covering six orders of magnitude in peptide concentration with and without a complex human cell digest background. We found that all methods performed very similarly in the absence of background proteins, however, when analyzing whole cell lysates, targeted methods were at least 5–10 times more sensitive than directed or DDA methods. In particular, higher stage fragmentation (MS3 of the neutral loss peak using a linear ion trap increased dynamic quantification range of some phosphopeptides up to 100-fold. We illustrate the power of this targeted MS3 approach for phosphopeptide monitoring by successfully quantifying 9 phosphorylation sites of the kinetochore and spindle assembly checkpoint component Mad1 over different cell cycle states from non-enriched pull-down samples. The data are associated to the research article ‘Evaluation of data-dependent and data-independent mass spectrometric workflows for sensitive quantification of proteins and phosphorylation sites׳ (Bauer et al., 2014 [1]. The mass spectrometry and the analysis dataset have been deposited to the ProteomeXchange Consortium (http://proteomecentral.proteomexchange.org via the PRIDE partner repository with the dataset identifier PXD000964.

  3. Characterization of ceramics used in mass ceramic industry Goianinha/RN

    International Nuclear Information System (INIS)

    Sales Junior, J.C.C.; Nascimento, R.M. do; Andrade, J.C.S.; Saldanha, K.M.; Dutra, R.P.S.

    2011-01-01

    The preparation of the the ceramic mass is one of the most important steps in the manufacture of ceramic products, since the characteristics of the raw materials used, and the proportions that they are added, directly influence the final properties of ceramic products and the operational conditions of processing. The objective of this paper is to present the results of the characterization of a ceramic mass used in the manufacture of sealing blocks by a red ceramic industry of the city of Goianinha / RN. We analyzed the chemical and mineralogical composition; thermogravimetric and differential thermal analysis; granulometric analysis; evaluation of plasticity; and determining the technological properties of specimens used in test firing at 700, 900 and 1100 ° C. The results show that the ceramic body studied has characteristics that allow use in the manufacture of sealing blocks when burned at a temperature of 900 ° C. (author)

  4. Neutrino masses and beyond from supersymmetry

    International Nuclear Information System (INIS)

    Kong, O.C.W.

    2004-01-01

    A generic form of the supersymmetric SM naturally gives rise to the lepton number violating neutrino masses and mixings, without the need for extra superfields beyond the minimal spectrum. Hence, SUSY can be considered the origin of beyond SM properties of neutrinos. We have developed a formulation under which one can efficiently analyze the model. Various sources of neutrino masses are discussed. Such mass contributions come from lepton number and flavor violating couplings that also give rise to a rich phenomenology of the neutrinos and other leptons, also to be discussed. (author)

  5. A Pivotal Study of Optoacoustic Imaging to Diagnose Benign and Malignant Breast Masses: A New Evaluation Tool for Radiologists.

    Science.gov (United States)

    Neuschler, Erin I; Butler, Reni; Young, Catherine A; Barke, Lora D; Bertrand, Margaret L; Böhm-Vélez, Marcela; Destounis, Stamatia; Donlan, Pamela; Grobmyer, Stephen R; Katzen, Janine; Kist, Kenneth A; Lavin, Philip T; Makariou, Erini V; Parris, Tchaiko M; Schilling, Kathy J; Tucker, F Lee; Dogan, Basak E

    2018-05-01

    Purpose To compare the diagnostic utility of an investigational optoacoustic imaging device that fuses laser optical imaging (OA) with grayscale ultrasonography (US) to grayscale US alone in differentiating benign and malignant breast masses. Materials and Methods This prospective, 16-site study of 2105 women (study period: 12/21/2012 to 9/9/2015) compared Breast Imaging Reporting and Data System (BI-RADS) categories assigned by seven blinded independent readers to benign and malignant breast masses using OA/US versus US alone. BI-RADS 3, 4, or 5 masses assessed at diagnostic US with biopsy-proven histologic findings and BI-RADS 3 masses stable at 12 months were eligible. Independent readers reviewed US images obtained with the OA/US device, assigned a probability of malignancy (POM) and BI-RADS category, and locked results. The same independent readers then reviewed OA/US images, scored OA features, and assigned OA/US POM and a BI-RADS category. Specificity and sensitivity were calculated for US and OA/US. Benign and malignant mass upgrade and downgrade rates, positive and negative predictive values, and positive and negative likelihood ratios were compared. Results Of 2105 consented subjects with 2191 masses, 100 subjects (103 masses) were analyzed separately as a training population and excluded. An additional 202 subjects (210 masses) were excluded due to technical failures or incomplete imaging, 72 subjects (78 masses) due to protocol deviations, and 41 subjects (43 masses) due to high-risk histologic results. Of 1690 subjects with 1757 masses (1079 [61.4%] benign and 678 [38.6%] malignant masses), OA/US downgraded 40.8% (3078/7535) of benign mass reads, with a specificity of 43.0% (3242/7538, 99% confidence interval [CI]: 40.4%, 45.7%) for OA/US versus 28.1% (2120/7543, 99% CI: 25.8%, 30.5%) for the internal US of the OA/US device. OA/US exceeded US in specificity by 14.9% (P < .0001; 99% CI: 12.9, 16.9%). Sensitivity for biopsied malignant masses was 96

  6. Direct mass measurements of neutron-deficient xenon isotopes using the ISOLTRAP mass spectrometer

    CERN Document Server

    Dilling, J; Beck, D; Bollen, G; Herfurth, F; Kellerbauer, A G; Kluge, H J; Moore, R B; Scheidenberger, C; Schwarz, S; Sikler, G

    2004-01-01

    The masses of the noble-gas Xe isotopes with 114 $\\leq$ A $\\leq$ 123 have been directly measured for the first time. The experiments were carried out with the ISOLTRAP triple trap spectrometer at the online mass separator ISOLDE/CERN. A mass resolving power of the Penning trap spectrometer of $m/\\Delta m$ of close to a million was chosen resulting in an accuracy of $\\delta m \\leq 13$ keV for all investigated isotopes. Conflicts with existing, indirectly obtained, mass data by several standard deviations were found and are discussed. An atomic mass evaluation has been performed and the results are compared to information from laser spectroscopy experiments and to recent calculations employing an interacting boson model.

  7. Body mass in comparative primatology.

    Science.gov (United States)

    Smith, R J; Jungers, W L

    1997-06-01

    Data are presented on adult body mass for 230 of 249 primate species, based on a review of the literature and previously unpublished data. The issues involved in collecting data on adult body mass are discussed, including the definition of adults, the effects of habitat and pregnancy, the strategy for pooling data on single species from multiple studies, and use of an appropriate number of significant figures. An analysis of variability in body mass indicates that the coefficient of variation for body mass increases with increasing species mean mass. Evaluation of several previous body mass reviews reveals a number of shortcomings with data that have been used often in comparative studies.

  8. Evaluation of Mass Housing at the Pre-Design Stage

    Directory of Open Access Journals (Sweden)

    Kozan UZUNOĞLU

    2014-09-01

    Full Text Available Throughout history, housing has been a central problem in the lives of human beings. Housing, which includes shelter for family and functional volumes that meet social needs, used to be built specifically for the family. The concept of “Mass Housing” entered the field of architecture as a result of the industrial revolution, when lavish Renaissance housing gradually turned into housing for workers. Today, the demand for housing cannot keep up with fast-growing populations. Besides the quantitative problems of housing production, there is the ever- growing problem of quality, the solution to which lies with designer architects. On this issue of quality, Post Occupation Evaluation (POE studies, conducted to provide data for upcoming designs, and certificate evaluations like LEED and BREEAM, aimed at measuring energy performance effectiveness of new buildings, mostly involve measurements of usage of the building envelope, environmental relations, facilities and usage of natural resources. None prioritize the form and function issues of spatial usage in architectural designs. This study proposes a method that enables spatial and functional measurement and assessment at the project stage. The suggested spatial performance measurement–assessment system has three stages. In the first stage, the standards and usage criteria to be used as reference in the assessment are defined. The second stage suggests using the SAR analysis approach, and the third stage is about conducting “Spatial Performance Assessment”. Here, the common denominator of “User System” and “Building System”, which shares characteristic design criteria “Form, Function,Construction” is established and by this way, testing and assessing the subject of study becomes possible. With these assessments, by providing digitalization of spatial performance with proportional values, it is believed that a database for the provision of statistical information may be established.

  9. [Evaluation of mass spectrometry for the identification of clinically interesting yeasts].

    Science.gov (United States)

    Galán, Fátima; García-Agudo, Lidia; Guerrero, Inmaculada; Marín, Pilar; García-Tapia, Ana; García-Martos, Pedro; Rodríguez-Iglesias, Manuel

    2015-01-01

    Identification of yeasts is based on morphological, biochemical and nutritional characteristics, and using molecular methods. Matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry, a new method for the identification of microorganisms, has demonstrated to be very useful. The aim of this study is to evaluate this new method in the identification of yeasts. A total of 600 strains of yeasts isolated from clinical specimens belonging to 9 genera and 43 species were tested. Identification was made by sequencing of the ITS regions of ribosomal DNA, assimilation of carbon compounds (ID 32C), and mass spectrometry on a Microflex spectrometer (Bruker Daltonics GmbH, Germany). A total of 569 strains (94.8%) were identified to species level by ID 32C, and 580 (96.7%) by MALDI-TOF. Concordance between both methods was observed for 553 strains (92.2%), with 100% in clinically relevant species: C. albicans, C. glabrata, C. parapsilosis, C. tropicalis, and almost 100% in C. krusei. MALDI-TOF identified species requiring molecular methods: Candida dubliniensis, C. nivariensis, C. metapsilosis and C. orthopsilosis. Some irregularities were observed in the identification of arthroconidia yeast and basidiomycetes. MALDI-TOF is a rapid, effective and economic method, which enables the identification of most clinically important yeasts and the differentiation of closely related species. It would be desirable to include more species in its database to expand its performance. Copyright © 2014 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  10. Analyzing Big Data in Psychology: A Split/Analyze/Meta-Analyze Approach

    Directory of Open Access Journals (Sweden)

    Mike W.-L. Cheung

    2016-05-01

    Full Text Available Big data is a field that has traditionally been dominated by disciplines such as computer science and business, where mainly data-driven analyses have been performed. Psychology, a discipline in which a strong emphasis is placed on behavioral theories and empirical research, has the potential to contribute greatly to the big data movement. However, one challenge to psychologists – and probably the most crucial one – is that most researchers may not have the necessary programming and computational skills to analyze big data. In this study we argue that psychologists can also conduct big data research and that, rather than trying to acquire new programming and computational skills, they should focus on their strengths, such as performing psychometric analyses and testing theories using multivariate analyses to explain phenomena. We propose a split/analyze/meta-analyze approach that allows psychologists to easily analyze big data. Two real datasets are used to demonstrate the proposed procedures in R. A new research agenda related to the analysis of big data in psychology is outlined at the end of the study.

  11. Analyzing Big Data in Psychology: A Split/Analyze/Meta-Analyze Approach.

    Science.gov (United States)

    Cheung, Mike W-L; Jak, Suzanne

    2016-01-01

    Big data is a field that has traditionally been dominated by disciplines such as computer science and business, where mainly data-driven analyses have been performed. Psychology, a discipline in which a strong emphasis is placed on behavioral theories and empirical research, has the potential to contribute greatly to the big data movement. However, one challenge to psychologists-and probably the most crucial one-is that most researchers may not have the necessary programming and computational skills to analyze big data. In this study we argue that psychologists can also conduct big data research and that, rather than trying to acquire new programming and computational skills, they should focus on their strengths, such as performing psychometric analyses and testing theories using multivariate analyses to explain phenomena. We propose a split/analyze/meta-analyze approach that allows psychologists to easily analyze big data. Two real datasets are used to demonstrate the proposed procedures in R. A new research agenda related to the analysis of big data in psychology is outlined at the end of the study.

  12. Identification of volatiles by headspace gas chromatography with simultaneous flame ionization and mass spectrometric detection.

    Science.gov (United States)

    Tiscione, Nicholas B; Yeatman, Dustin Tate; Shan, Xiaoqin; Kahl, Joseph H

    2013-10-01

    Volatiles are frequently abused as inhalants. The methods used for identification are generally nonspecific if analyzed concurrently with ethanol or require an additional analytical procedure that employs mass spectrometry. A previously published technique utilizing a capillary flow technology splitter to simultaneously quantitate and confirm ethyl alcohol by flame ionization and mass spectrometric detection after headspace sampling and gas chromatographic separation was evaluated for the detection of inhalants. Methanol, isopropanol, acetone, acetaldehyde, toluene, methyl ethyl ketone, isoamyl alcohol, isobutyl alcohol, n-butyl alcohol, 1,1-difluoroethane, 1,1,1-trifluoroethane, 1,1,1,2-tetrafluoroethane (Norflurane, HFC-134a), chloroethane, trichlorofluoromethane (Freon®-11), dichlorodifluoromethane (Freon®-12), dichlorofluoromethane (Freon®-21), chlorodifluoromethane (Freon®-22) and 1,2-dichlorotetrafluoroethane (Freon®-114) were validated for qualitative identification by this method. The validation for qualitative identification included evaluation of matrix effects, sensitivity, carryover, specificity, repeatability and ruggedness/robustness.

  13. Climate Model Diagnostic Analyzer

    Science.gov (United States)

    Lee, Seungwon; Pan, Lei; Zhai, Chengxing; Tang, Benyang; Kubar, Terry; Zhang, Zia; Wang, Wei

    2015-01-01

    The comprehensive and innovative evaluation of climate models with newly available global observations is critically needed for the improvement of climate model current-state representation and future-state predictability. A climate model diagnostic evaluation process requires physics-based multi-variable analyses that typically involve large-volume and heterogeneous datasets, making them both computation- and data-intensive. With an exploratory nature of climate data analyses and an explosive growth of datasets and service tools, scientists are struggling to keep track of their datasets, tools, and execution/study history, let alone sharing them with others. In response, we have developed a cloud-enabled, provenance-supported, web-service system called Climate Model Diagnostic Analyzer (CMDA). CMDA enables the physics-based, multivariable model performance evaluations and diagnoses through the comprehensive and synergistic use of multiple observational data, reanalysis data, and model outputs. At the same time, CMDA provides a crowd-sourcing space where scientists can organize their work efficiently and share their work with others. CMDA is empowered by many current state-of-the-art software packages in web service, provenance, and semantic search.

  14. Imaging mass spectrometry statistical analysis.

    Science.gov (United States)

    Jones, Emrys A; Deininger, Sören-Oliver; Hogendoorn, Pancras C W; Deelder, André M; McDonnell, Liam A

    2012-08-30

    Imaging mass spectrometry is increasingly used to identify new candidate biomarkers. This clinical application of imaging mass spectrometry is highly multidisciplinary: expertise in mass spectrometry is necessary to acquire high quality data, histology is required to accurately label the origin of each pixel's mass spectrum, disease biology is necessary to understand the potential meaning of the imaging mass spectrometry results, and statistics to assess the confidence of any findings. Imaging mass spectrometry data analysis is further complicated because of the unique nature of the data (within the mass spectrometry field); several of the assumptions implicit in the analysis of LC-MS/profiling datasets are not applicable to imaging. The very large size of imaging datasets and the reporting of many data analysis routines, combined with inadequate training and accessible reviews, have exacerbated this problem. In this paper we provide an accessible review of the nature of imaging data and the different strategies by which the data may be analyzed. Particular attention is paid to the assumptions of the data analysis routines to ensure that the reader is apprised of their correct usage in imaging mass spectrometry research. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. RADHEAT-V4: a code system to generate multigroup constants and analyze radiation transport for shielding safety evaluation

    International Nuclear Information System (INIS)

    Yamano, Naoki; Minami, Kazuyoshi; Koyama, Kinji; Naito, Yoshitaka.

    1989-03-01

    A modular code system RADHEAT-V4 has been developed for performing precisely neutron and photon transport analyses, and shielding safety evaluations. The system consists of the functional modules for producing coupled multi-group neutron and photon cross section sets, for analyzing the neutron and photon transport, and for calculating the atom displacement and the energy deposition due to radiations in nuclear reactor or shielding material. A precise method named Direct Angular Representation (DAR) has been developed for eliminating an error associated with the method of the finite Legendre expansion in evaluating angular distributions of cross sections and radiation fluxes. The DAR method implemented in the code system has been described in detail. To evaluate the accuracy and applicability of the code system, some test calculations on strong anisotropy problems have been performed. From the results, it has been concluded that RADHEAT-V4 is successfully applicable to evaluating shielding problems accurately for fission and fusion reactors and radiation sources. The method employed in the code system is very effective in eliminating negative values and oscillations of angular fluxes in a medium having an anisotropic source or strong streaming. Definitions of the input data required in various options of the code system and the sample problems are also presented. (author)

  16. Transvaginal sonographic appearance of cystic adnexal masses in postmenopausal women

    International Nuclear Information System (INIS)

    Cho, Hyeun Cha; Lee, Myung Sook

    2000-01-01

    To Analyze the transvaginal ultrasonographic(TVUS)findings of the cystic adnexal masses in postmenopausal women for differentiation of benign and malignant masses. We retrospectively reviewed the TVUS images of surgically proven 142 cystic adnexal masses in 125 patients. The masses were classified according to the pathologic findings. The size, the internal echogenicity, the internal septation, the external wall of the masses on US were analyzed and scored using Multicenter scoring system. Serum CA-125 concentration was also recorded. At surgery of 142 masses, 125 benign (88%), and 17 borderline/malignant masses (12%) were found. Among 125 benign masses, 88 masses were larger than 5 cm, 125 had smooth external wall, 109 had absence or thin internal septation, and 107 had anechoic or homogenous low internal echogenicity. Of the 17 borderline/malignant masses, there were 17 masses larger than 5 cm, 2 with smooth external wall, 12 without or with thin internal septation, and 7 with anechoic or homogenous low internal echogenicity. Multicenter score was below 8 in all benign masses, and in 4 borderline/malignant masses. Serum CA-125 concentration with normal range was in 90 patients with benign masses, and in 2 patients with borderline/malignant masses. Cystic adnexal masses with smooth external wall and internal septation, internal echogenic portion less than 10%, score below 8 on TVUS would be diagnosed as benign masses in postmenopausal women with normal serum CA-125 concentration.

  17. Social education of youth with mass media

    OpenAIRE

    Ryazanova A.; Zakirova A.

    2017-01-01

    This article reveals the influence of mass media; the concepts of education, the distinctive influence and different types, methods and mechanisms of mass media. The object of the study is the social education of young people. The subject is the synthesis of social educator’s work with the youth using the mass media. The aim of the work is to analyze the social educator’s work. Methods: theoretical analysis of literature, work’s synthesis of the specialist.

  18. Ultra High-Mass Resolution Paper Spray by Fourier Transform Ion Cyclotron Resonance Mass Spectrometry

    Directory of Open Access Journals (Sweden)

    Kevin D. Quinn

    2012-01-01

    Full Text Available Paper Spray Ionization is an atmospheric pressure ionization technique that utilizes an offline electro-osmotic flow to generate ions off a paper medium. This technique can be performed on a Bruker SolariX Fourier transform ion cyclotron resonance mass spectrometer by modifying the existing nanospray source. High-resolution paper spray spectra were obtained for both organic and biological samples to demonstrate the benefit of linking the technique with a high-resolution mass analyzer. Error values in the range 0.23 to 2.14 ppm were obtained for calf lung surfactant extract with broadband mass resolving power (m/Δm50% above 60,000 utilizing an external calibration standard.

  19. The application of an optical Fourier spectrum analyzer on detecting defects in mass-produced satellite photographs

    Science.gov (United States)

    Athale, R.; Lee, S. H.

    1976-01-01

    Various defects in mass-produced pictures transmitted to earth from a satellite are investigated. It is found that the following defects are readily detectable via Fourier spectrum analysis: (1) bit slip, (2) breakup causing loss of image, and (3) disabled track at the top of the imagery. The scratches made on the film during mass production, which are difficult to detect by visual observation, also show themselves readily in Fourier spectrum analysis. A relation is established between the number of scratches, their width and depth and the intensity of their Fourier spectra. Other defects that are found to be equally suitable for Fourier spectrum analysis or visual (image analysis) detection are synchronous loss without blurring of image, and density variation in gray scale. However, the Fourier spectrum analysis is found to be unsuitable for detection of such defects as pin holes, annotation error, synchronous loss with blurring of images, and missing image in the beginning of the work order. The design of an automated, real time system, which will reject defective films, is treated.

  20. Assessment of methods for analyzing gaseous mixtures of hydrogen isotopes and helium

    International Nuclear Information System (INIS)

    Attalla, A.; Bishop, C.T.; Bohl, D.R.; Buxton, T.L.; Sprague, R.E.; Warner, D.K.

    1976-01-01

    Mass spectrographic methods have served well in the past to analyze gaseous mixtures of the hydrogen isotopes. Alternate methods of analyses are reviewed which offer wider ranges and variety of isotopic determinations. This report describes possible improvements of the mass spectrographic determinations, gas chromatography, anti-Stokes Raman spectroscopy, microwave-induced optical emission spectroscopy, and methods of measuring tritium using radiation detection devices. Precision, accuracy, limitations, and costs are included for some of the methods mentioned. Costs range from $70,000 for the anti-Stokes Raman spectroscopy equipment, which can determine hydrogen isotopes but not helium, to less than $10,000 for the gas chromatographic equipment, which can determine hydrogen isotopes and helium with precision and accuracy comparable to those of the mass spectrometer

  1. New ultra small battery operated portable multi-channel analyzer

    International Nuclear Information System (INIS)

    Wolf, M.A.; Umbarger, C.J.

    1979-01-01

    A newly designed portable multi-channel analyzer (MCA) has been developd at Los Alamos that has much improved physical and performance characteristics over previous designs. Namely, the instrument is very compact (25 cm wide x 14 cm deep x 21 cm high) and has a mass of 4.2 Kg (9.2 lb). The device has 1024 channels and is microprocessor controlled. The instrument has most of the standard features of present laboratory-based pulse height analyzers, including CRT display, region of interest integration, etc. Battery life of the MCA is nearly eight hours, with full charging over night. An accessory case carries a small audio cassette recorder for data storage. The case also contains two different NaI(Tl) detectors

  2. Delta opioid receptor on equine sperm cells: subcellular localization and involvement in sperm motility analyzed by computer assisted sperm analyzer (CASA

    Directory of Open Access Journals (Sweden)

    Lacalandra Giovanni M

    2010-06-01

    Full Text Available Abstract Background Opioid receptors and endogenous opioid peptides act not only in the control of nociceptive pathways, indeed several reports demonstrate the effects of opiates on sperm cell motility and morphology suggesting the importance of these receptors in the modulation of reproduction in mammals. In this study we investigated the expression of delta opioid receptors on equine spermatozoa by western blot/indirect immunofluorescence and its relationship with sperm cell physiology. Methods We analyzed viability, motility, capacitation, acrosome reaction and mitochondrial activity in the presence of naltrindole and DPDPE by means of a computer assisted sperm analyzer and a fluorescent confocal microscope. The evaluation of viability, capacitation and acrosome reaction was carried out by the double CTC/Hoechst staining, whereas mitochondrial activity was assessed by means of MitoTracker Orange dye. Results We showed that in equine sperm cells, delta opioid receptor is expressed as a doublet of 65 and 50 kDa molecular mass and is localized in the mid piece of tail; we also demonstrated that naltrindole, a delta opioid receptor antagonist, could be utilized in modulating several physiological parameters of the equine spermatozoon in a dose-dependent way. We also found that low concentrations of the antagonist increase sperm motility whereas high concentrations show the opposite effect. Moreover low concentrations hamper capacitation, acrosome reaction and viability even if the percentage of cells with active mitochondria seems to be increased; the opposite effect is exerted at high concentrations. We have also observed that the delta opioid receptor agonist DPDPE is scarcely involved in affecting the same parameters at the employed concentrations. Conclusions The results described in this paper add new important details in the comprehension of the mammalian sperm physiology and suggest new insights for improving reproduction and for

  3. Optimization of Reversed-Phase Peptide Liquid Chromatography Ultraviolet Mass Spectrometry Analyses Using an Automated Blending Methodology

    Science.gov (United States)

    Chakraborty, Asish B.; Berger, Scott J.

    2005-01-01

    The balance between chromatographic performance and mass spectrometric response has been evaluated using an automated series of experiments where separations are produced by the real-time automated blending of water with organic and acidic modifiers. In this work, the concentration effects of two acidic modifiers (formic acid and trifluoroacetic acid) were studied on the separation selectivity, ultraviolet, and mass spectrometry detector response, using a complex peptide mixture. Peptide retention selectivity differences were apparent between the two modifiers, and under the conditions studied, trifluoroacetic acid produced slightly narrower (more concentrated) peaks, but significantly higher electrospray mass spectrometry suppression. Trifluoroacetic acid suppression of electrospray signal and influence on peptide retention and selectivity was dominant when mixtures of the two modifiers were analyzed. Our experimental results indicate that in analyses where the analyzed components are roughly equimolar (e.g., a peptide map of a recombinant protein), the selectivity of peptide separations can be optimized by choice and concentration of acidic modifier, without compromising the ability to obtain effective sequence coverage of a protein. In some cases, these selectivity differences were explored further, and a rational basis for differentiating acidic modifier effects from the underlying peptide sequences is described. PMID:16522853

  4. Isobar Separation in a Multiple-Reflection Time-of-Flight Mass Spectrometer by Mass-Selective Re-Trapping

    Science.gov (United States)

    Dickel, Timo; Plaß, Wolfgang R.; Lippert, Wayne; Lang, Johannes; Yavor, Mikhail I.; Geissel, Hans; Scheidenberger, Christoph

    2017-06-01

    A novel method for (ultra-)high-resolution spatial mass separation in time-of-flight mass spectrometers is presented. Ions are injected into a time-of-flight analyzer from a radio frequency (rf) trap, dispersed in time-of-flight according to their mass-to-charge ratios and then re-trapped dynamically in the same rf trap. This re-trapping technique is highly mass-selective and after sufficiently long flight times can provide even isobaric separation. A theoretical treatment of the method is presented and the conditions for optimum performance of the method are derived. The method has been implemented in a multiple-reflection time-of-flight mass spectrometer and mass separation powers (FWHM) in excess of 70,000, and re-trapping efficiencies of up to 35% have been obtained for the protonated molecular ion of caffeine. The isobars glutamine and lysine (relative mass difference of 1/4000) have been separated after a flight time of 0.2 ms only. Higher mass separation powers can be achieved using longer flight times. The method will have important applications, including isobar separation in nuclear physics and (ultra-)high-resolution precursor ion selection in multiple-stage tandem mass spectrometry. [Figure not available: see fulltext.

  5. Evaluation of cryoanalysis as a tool for analyzing elemental distribution in “live” tardigrades using micro-PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, E.J.C., E-mail: charlotta.nilsson@nuclear.lu.se [Division of Nuclear Physics, Department of Physics, Lund University, Box 118, SE-221 00 Lund (Sweden); Pallon, J., E-mail: jan.pallon@nuclear.lu.se [Division of Nuclear Physics, Department of Physics, Lund University, Box 118, SE-221 00 Lund (Sweden); Przybylowicz, W.J., E-mail: przybylowicz@tlabs.ac.za [Materials Research Department, iThemba LABS, National Research Foundation, P.O. Box 722, Somerset West 7129 (South Africa); AGH University of Science and Technology, Faculty of Physics and Applied Computer Science, Al. A. Mickiewicza 30, 30-059 Krakow (Poland); Wang, Y.D., E-mail: yaodongw@hotmail.com [Materials Research Department, iThemba LABS, National Research Foundation, P.O. Box 722, Somerset West 7129 (South Africa); Jönsson, K.I., E-mail: ingemar.jonsson@hkr.se [School of Education and Environment, Kristianstad University, SE-291 88 Kristianstad (Sweden); Department of Molecular Biosciences, The Wenner-Gren Institute, Stockholm University, SE-106 91 Stockholm (Sweden)

    2014-08-01

    Although heavy on labor and equipment, thus not often applied, cryoanalysis of frozen hydrated biological specimens can provide information that better reflects the living state of the organism, compared with analysis in the freeze-dried state. In this paper we report a study where the cryoanalysis facility with cryosectioning capabilities at Materials Research Department, iThemba LABS, South Africa was employed to evaluate the usefulness of combining three ion beam analytical methods (μPIXE, RBS and STIM) to analyze a biological target where a better elemental compositional description is needed – the tardigrade. Imaging as well as quantification results are of interest. In a previous study, the element composition and redistribution of elements in the desiccated and active states of two tardigrade species was investigated. This study included analysis of both whole and sectioned tardigrades, and the aim was to analyze each specimen twice; first frozen hydrated and later freeze-dried. The combination of the three analytical techniques proved useful: elements from C to Rb in the tardigrades could be determined and certain differences in distribution of elements between the frozen hydrated and the freeze-dried states were observed. RBS on frozen hydrated specimens provided knowledge of matrix elements.

  6. Mass Properties for Space Systems Standards Development

    Science.gov (United States)

    Beech, Geoffrey

    2013-01-01

    Current Verbiage in S-120 Applies to Dry Mass. Mass Margin is difference between Required Mass and Predicted Mass. Performance Margin is difference between Predicted Performance and Required Performance. Performance estimates and corresponding margin should be based on Predicted Mass (and other inputs). Contractor Mass Margin reserved from Performance Margin. Remaining performance margin allocated according to mass partials. Compliance can be evaluated effectively by comparison of three areas (preferably on a single sheet). Basic and Predicted Mass (including historical trend). Aggregate potential changes (threats and opportunities) which gives Mass Forecast. Mass Maturity by category (Estimated/Calculated/Actual).

  7. Biomechanics of the cornea evaluated by spectral analysis of waveforms from ocular response analyzer and Corvis-ST.

    Directory of Open Access Journals (Sweden)

    Sushma Tejwani

    Full Text Available In this study, spectral analysis of the deformation signal from Corvis-ST (CoST and reflected light intensity from ocular response analyzer (ORA was performed to evaluate biomechanical concordance with each other.The study was non-interventional, observational, cross-sectional and involved 188 eyes from 94 normal subjects. Three measurements were made on each eye with ORA and CoST each and then averaged for each device. The deformation signal from CoST and reflected light intensity (applanation signal from ORA was compiled for all the eyes. The ORA signal was inverted about a line joining the two applanation peaks. All the signals were analyzed with Fourier series. The area under the signal curves (AUC, root mean square (RMS of all the harmonics, lower order (LO included 1st and 2nd order harmonic, higher order (HO up to 6th harmonic, CoST deformation amplitude (DA, corneal hysteresis (CH and corneal resistance factor (CRF were analyzed.The device variables and those calculated by Fourier transform were statistically significantly different between CoST and ORA. These variables also differed between the eyes of the same subject. There was also statistically significant influence of eyes (left vs. right on the differences in a sub-set of RMS variables only. CH and CRF differed statistically significantly between the eyes of subject (p<0.001 but not DA (p = 0.65.CoST was statistically significantly different from ORA. CoST may be useful in delineating true biomechanical differences between the eyes of a subject as it reports deformation.

  8. Strange and charm baryon masses with two flavors of dynamical twisted mass fermions

    Energy Technology Data Exchange (ETDEWEB)

    Alexandrou, C. [Univ. of Cyprus, Nicosia (Cyprus). Dept. of Physics; Cyprus Institute, Nicosia (Cyprus). Computation-Based Science and Technology Research Center; Carbonell, J. [CEA-Saclay, Gif-sur-Yvette (France). IRFU/Service de Physique Nucleaire; Christaras, D.; Gravina, M. [Univ. of Cyprus, Nicosia (Cyprus). Dept. of Physics; Drach, V. [Deutsches Elektronen-Synchrotron (DESY), Zeuthen (Germany). John von Neumann-Inst. fuer Computing NIC; Papinutto, M. [UFJ/CNRS/IN2P3, Grenoble (France). Laboratoire de Physique Subatomique et Cosmologie; Universidad Autonoma de Madrid (Spain). Dept. de Fisica Teorica; Universidad Autonoma de Madrid UAM/CSIC (Spain). Inst. de Fisica Teorica

    2012-10-15

    The masses of the low-lying strange and charm baryons are evaluated using two degenerate flavors of twisted mass sea quarks for pion masses in the range of about 260 MeV to 450 MeV. The strange and charm valence quark masses are tuned to reproduce the mass of the kaon and D-meson at the physical point. The tree-level Symanzik improved gauge action is employed. We use three values of the lattice spacing, corresponding to {beta}=3.9, {beta}=4.05 and {beta}=4.2 with r{sub 0}/a=5.22(2), r{sub 0}/a=6.61(3) and r{sub 0}/a=8.31(5) respectively. We examine the dependence of the strange and charm baryons on the lattice spacing and strange and charm quark masses. The pion mass dependence is studied and physical results are obtained using heavy baryon chiral perturbation theory to extrapolate to the physical point.

  9. Teacher Evaluation within the Public Agenda

    Directory of Open Access Journals (Sweden)

    Minerva Nava Amaya

    2014-04-01

    Full Text Available The presence of the teacher performance evaluation in the public agenda is analyzed, indicating the role that the mass media have had in it. Is proposed to incorporate into the discussion elements from research experiences, in order to tackle the topic in a documented and analytical way. Considering the disparities of the educational scene, is indicated the need to provide the teacher of the indispensable conditions for his suitable performance, like a request before to the evaluation. The design and interpretation of evaluation results must consider the diversity of profiles, of institutional, sociocultural and economic contexts in which the teaching is exercised. Finally, some aspects are highlighted to consider in the design of politics and actions in order to favor the progress of the performance and the teaching evaluation.

  10. Electrostatic micromanipulation of a conductive particle by a single probe with consideration of an error in the evaluated mass

    International Nuclear Information System (INIS)

    Sawai, Kenji; Saito, Shigeki

    2010-01-01

    Recently, micromanipulation techniques for handling a conductive microparticle have been in demand. Electrostatic micromanipulation with a single probe is a promising technique for such manipulation. While the feasibility of the technique has been proved experimentally, the success rate of manipulation was 25%, and further improvements are required. To enhance the success rate and realize highly reliable electrostatic micromanipulation, this paper proposes an improved design of a voltage sequence which is applied to deposit a microparticle onto a substrate plate. It was found through investigation that the error in the evaluated mass of a microparticle must be considered in order to improve the success rate of the manipulation. Behavior of a microparticle during the electrostatic micromanipulation is calculated by a boundary element method, and the influence of error is discussed. An improved design of the applied voltage sequence that can tolerate an error in the evaluated mass is described. Moreover, the effectiveness of the newly designed voltage sequence in the electrostatic micromanipulation is experimentally shown.

  11. Automated analysis of non-mass-enhancing lesions in breast MRI based on morphological, kinetic, and spatio-temporal moments and joint segmentation-motion compensation technique

    Science.gov (United States)

    Hoffmann, Sebastian; Shutler, Jamie D.; Lobbes, Marc; Burgeth, Bernhard; Meyer-Bäse, Anke

    2013-12-01

    Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) represents an established method for the detection and diagnosis of breast lesions. While mass-like enhancing lesions can be easily categorized according to the Breast Imaging Reporting and Data System (BI-RADS) MRI lexicon, a majority of diagnostically challenging lesions, the so called non-mass-like enhancing lesions, remain both qualitatively as well as quantitatively difficult to analyze. Thus, the evaluation of kinetic and/or morphological characteristics of non-masses represents a challenging task for an automated analysis and is of crucial importance for advancing current computer-aided diagnosis (CAD) systems. Compared to the well-characterized mass-enhancing lesions, non-masses have no well-defined and blurred tumor borders and a kinetic behavior that is not easily generalizable and thus discriminative for malignant and benign non-masses. To overcome these difficulties and pave the way for novel CAD systems for non-masses, we will evaluate several kinetic and morphological descriptors separately and a novel technique, the Zernike velocity moments, to capture the joint spatio-temporal behavior of these lesions, and additionally consider the impact of non-rigid motion compensation on a correct diagnosis.

  12. Detection of intact megadalton protein assemblies of vanillyl-alcohol oxidase by mass spectrometry

    NARCIS (Netherlands)

    Berkel, van W.J.H.; Heuvel, van den R.H.H.; Versluis, C.; Heck, A.

    2000-01-01

    Well-resolved ion signals of intact large protein assemblies, with molecular masses extending above one million Dalton, have been detected and mass analyzed using electrospray ionization mass spectrometry, with an uncertainty in mass of <0.2&Eth;The mass spectral data seem to reflect known

  13. Greenland ice sheet surface mass balance: evaluating simulations and making projections with regional climate models

    Directory of Open Access Journals (Sweden)

    J. G. L. Rae

    2012-11-01

    Full Text Available Four high-resolution regional climate models (RCMs have been set up for the area of Greenland, with the aim of providing future projections of Greenland ice sheet surface mass balance (SMB, and its contribution to sea level rise, with greater accuracy than is possible from coarser-resolution general circulation models (GCMs. This is the first time an intercomparison has been carried out of RCM results for Greenland climate and SMB. Output from RCM simulations for the recent past with the four RCMs is evaluated against available observations. The evaluation highlights the importance of using a detailed snow physics scheme, especially regarding the representations of albedo and meltwater refreezing. Simulations with three of the RCMs for the 21st century using SRES scenario A1B from two GCMs produce trends of between −5.5 and −1.1 Gt yr−2 in SMB (equivalent to +0.015 and +0.003 mm sea level equivalent yr−2, with trends of smaller magnitude for scenario E1, in which emissions are mitigated. Results from one of the RCMs whose present-day simulation is most realistic indicate that an annual mean near-surface air temperature increase over Greenland of ~ 2°C would be required for the mass loss to increase such that it exceeds accumulation, thereby causing the SMB to become negative, which has been suggested as a threshold beyond which the ice sheet would eventually be eliminated.

  14. IOTA Simple Rules in Differentiating between Benign and Malignant Adnexal Masses by Non-expert Examiners.

    Science.gov (United States)

    Tinnangwattana, Dangcheewan; Vichak-Ururote, Linlada; Tontivuthikul, Paponrad; Charoenratana, Cholaros; Lerthiranwong, Thitikarn; Tongsong, Theera

    2015-01-01

    To evaluate the diagnostic performance of IOTA simple rules in predicting malignant adnexal tumors by non-expert examiners. Five obstetric/gynecologic residents, who had never performed gynecologic ultrasound examination by themselves before, were trained for IOTA simple rules by an experienced examiner. One trained resident performed ultrasound examinations including IOTA simple rules on 100 women, who were scheduled for surgery due to ovarian masses, within 24 hours of surgery. The gold standard diagnosis was based on pathological or operative findings. The five-trained residents performed IOTA simple rules on 30 patients for evaluation of inter-observer variability. A total of 100 patients underwent ultrasound examination for the IOTA simple rules. Of them, IOTA simple rules could be applied in 94 (94%) masses including 71 (71.0%) benign masses and 29 (29.0%) malignant masses. The diagnostic performance of IOTA simple rules showed sensitivity of 89.3% (95%CI, 77.8%; 100.7%), specificity 83.3% (95%CI, 74.3%; 92.3%). Inter-observer variability was analyzed using Cohen's kappa coefficient. Kappa indices of the four pairs of raters are 0.713-0.884 (0.722, 0.827, 0.713, and 0.884). IOTA simple rules have high diagnostic performance in discriminating adnexal masses even when are applied by non-expert sonographers, though a training course may be required. Nevertheless, they should be further tested by a greater number of general practitioners before widely use.

  15. Proceedings of the twenty ninth ISMAS international symposium on mass spectrometry

    International Nuclear Information System (INIS)

    Aggarwal, Suresh K.; Pranaw Kumar; Jaison, P.G.; Sarkar, Arnab; Telmore, Vijay M.

    2015-02-01

    Mass spectrometry is a truly multi-disciplinary science and has emerged as an indispensable analytical tool due to its high sensitivity, specificity and universality. It is playing a key role in variety of scientific disciplines of chemistry, physics, biology, archaeology, material science etc. Progress in the field of mass spectrometry in the last two decades has led to the advent of new ion sources, improvements in existing mass analyzers and introduction of hybrid mass analyzers. As the technique continues to advance, many new applications have emerged particularly in health sciences and for forensic applications. The current world scenario demands determination at single atom and single molecule with high specificity. The vendors in the international mass spectrometric instrumentation market are guided by these requirements as well as the inputs from mass spectrometrists around the world engaged in new developments. Papers relevant to INIS are indexed separately

  16. Experiments for obtaining field influence mass particles.

    CERN Document Server

    Yahalomi, E

    2010-01-01

    Analyzing time dilation experiments the existence of a universal field interacting with moving mass particles is obtained. It is found that mass particle changes its properties depend on its velocity relative to this universal scalar field and not on its velocity relative to the laboratory. High energy proton momentum, energy and mass were calculated obtaining new results. Experiments in high energy accelerators are suggested as additional proofs for the existence of this universal field. This universal field may explain some results of other high energy experiments.

  17. Massive gravity with mass term in three dimensions

    International Nuclear Information System (INIS)

    Nakasone, Masashi; Oda, Ichiro

    2009-01-01

    We analyze the effect of the Pauli-Fierz mass term on a recently established, new massive gravity theory in three space-time dimensions. We show that the Pauli-Fierz mass term makes the new massive gravity theory nonunitary. Moreover, although we add the gravitational Chern-Simons term to this model, the situation remains unchanged and the theory stays nonunitary despite that the structure of the graviton propagator is greatly changed. Thus, the Pauli-Fierz mass term is not allowed to coexist with mass-generating higher-derivative terms in the new massive gravity.

  18. Theory for added mass of a vibrating circular rod in a two-phase air-water fluid

    International Nuclear Information System (INIS)

    Kohgo, Osamu; Hara, Fumio

    1985-01-01

    It has been well known that there are added mass and attenuation effect due to surrounding fluid in a structure vibrating in the fluid, and those are different according to the density and viscosity of the fluid and the form of the structure. In this study, in order to clarify added mass, the model of the vapor-liquid two-phase fluid with discontinuous density distribution was made. That is, bubbles were assumed to be a bubble column without bending stiffness and mass, and potential analysis was applied to a two-dimensional fluid field composed of a round section beam and the bubble column, thus their relative motion was hydrodynamically analyzed, and the theory for evaluating added mass was developed. The added mass experimentally determined from the response gain of a single round section cantilever when it was oscillated steadily, uniformly and at random in the vapor-liquid two-phase fluid being stationary as a whole and the theoretical result were examined by comparison, and equivalent bubble diameter was considered, thereafter, the validity of the model was examined. (Kako, I.)

  19. Mechanistic model of mass-specific basal metabolic rate: evaluation in healthy young adults.

    Science.gov (United States)

    Wang, Z; Bosy-Westphal, A; Schautz, B; Müller, M

    2011-12-01

    Mass-specific basal metabolic rate (mass-specific BMR), defined as the resting energy expenditure per unit body mass per day, is an important parameter in energy metabolism research. However, a mechanistic explanation for magnitude of mass-specific BMR remains lacking. The objective of the present study was to validate the applicability of a proposed mass-specific BMR model in healthy adults. A mechanistic model was developed at the organ-tissue level, mass-specific BMR = Σ( K i × F i ), where Fi is the fraction of body mass as individual organs and tissues, and K i is the specific resting metabolic rate of major organs and tissues. The Fi values were measured by multiple MRI scans and the K i values were suggested by Elia in 1992. A database of healthy non-elderly non-obese adults (age 20 - 49 yrs, BMI BMR of all subjects was 21.6 ± 1.9 (mean ± SD) and 21.7 ± 1.6 kcal/kg per day, respectively. The measured mass-specific BMR was correlated with the predicted mass-specific BMR (r = 0.82, P BMR, versus the average of measured and predicted mass-specific BMR. In conclusion, the proposed mechanistic model was validated in non-elderly non-obese adults and can help to understand the inherent relationship between mass-specific BMR and body composition.

  20. Mass Spectrometry for Large Undergraduate Laboratory Sections

    Science.gov (United States)

    Illies, A.; Shevlin, P. B.; Childers, G.; Peschke, M.; Tsai, J.

    1995-08-01

    Mass spectrometry is routinely covered in undergraduate organic chemistry courses and a number of valuable laboratory experiments featuring its use have been discussed (1-7). Although such experiments work well at institutions with limited laboratory enrollments, we typically teach laboratories with enrollments of 160 or more in which it is difficult to allow each student to carry out a meaningful "hands on" mass spectrometry experiment. Since we feel that some practical experience with this technique is important, we have designed a simple gas chromatography-mass spectrometry (gc/ms) exercise that allows each student to analyze the products of a simple synthesis that they have performed. The exercise starts with the microscale SN2 synthesis of 1-bromobutane from 1-butanol as described by Williamson (8). The students complete the synthesis and place one drop of the distilled product in a screw capped vial. The vials are then sealed, labeled with the students name and taken to the mass spectrometry laboratory by a teaching assistant. Students are instructed to sign up for a 20-min block of time over the next few days in order to analyze their sample. When the student arrives at the laboratory, he or she adds 1 ml CH2Cl2 to the sample and injects 0.3 microliters of the solution into the gas chromatograph. The samples typically contain the 1-butanol starting material and the 1-bromobutane product along with traces of dibutyl ether. The figure shows a mass chromatogram along with the mass spectra of the starting material and product from an actual student run. For this analysis to be applicable to large numbers of students, the gc separation must be as rapid as possible. We have been able to analyze each sample in 6 minutes on a 30 m DB-5 capillary column with the following temperature program: 70 oC for 1 min, 70-80 oC at 10 oC/min, 86-140 oC at 67.5 oC/min, 140-210 oC at 70 oC/min, and 210 oC for 1 min. A mass range of 20-200 amu is scanned with a solvent delay of 2

  1. Proteomic Biomarker Discovery in 1000 Human Plasma Samples with Mass Spectrometry.

    Science.gov (United States)

    Cominetti, Ornella; Núñez Galindo, Antonio; Corthésy, John; Oller Moreno, Sergio; Irincheeva, Irina; Valsesia, Armand; Astrup, Arne; Saris, Wim H M; Hager, Jörg; Kussmann, Martin; Dayon, Loïc

    2016-02-05

    The overall impact of proteomics on clinical research and its translation has lagged behind expectations. One recognized caveat is the limited size (subject numbers) of (pre)clinical studies performed at the discovery stage, the findings of which fail to be replicated in larger verification/validation trials. Compromised study designs and insufficient statistical power are consequences of the to-date still limited capacity of mass spectrometry (MS)-based workflows to handle large numbers of samples in a realistic time frame, while delivering comprehensive proteome coverages. We developed a highly automated proteomic biomarker discovery workflow. Herein, we have applied this approach to analyze 1000 plasma samples from the multicentered human dietary intervention study "DiOGenes". Study design, sample randomization, tracking, and logistics were the foundations of our large-scale study. We checked the quality of the MS data and provided descriptive statistics. The data set was interrogated for proteins with most stable expression levels in that set of plasma samples. We evaluated standard clinical variables that typically impact forthcoming results and assessed body mass index-associated and gender-specific proteins at two time points. We demonstrate that analyzing a large number of human plasma samples for biomarker discovery with MS using isobaric tagging is feasible, providing robust and consistent biological results.

  2. A Systematic Search and Review of Adult-Targeted Overweight and Obesity Prevention Mass Media Campaigns and Their Evaluation: 2000-2017.

    Science.gov (United States)

    Kite, James; Grunseit, Anne; Bohn-Goldbaum, Erika; Bellew, Bill; Carroll, Tom; Bauman, Adrian

    2018-01-01

    Mass media campaigns are a commonly used strategy in public health. However, no review has assessed whether the design and evaluation of overweight and obesity campaigns meets best practice recommendations. This study aimed to fill this gap. We systematically searched five databases for peer-reviewed articles describing adult-targeted obesity mass media campaigns published between 2000 and 2017, complemented by reference list searches and contact with authors and agencies responsible for the campaigns. We extracted data on campaign design, implementation, and evaluation from eligible publications and conducted a qualitative review of 29 publications reporting on 14 campaigns. We found a need for formative research with target audiences to ensure campaigns focus on the most salient issues. Further, we noted that most campaigns targeted individual behaviors, despite calls for campaigns to also focus upstream and to address social determinants of obesity. Television was the dominant communication channel but, with the rapid advance of digital media, evaluation of other channels, such as social media, is increasingly important. Finally, although evaluation methods varied in quality, the evidence suggests that campaigns can have an impact on intermediate outcomes, such as knowledge and attitudes. However, evidence is still limited as to whether campaigns can influence behavior change.

  3. Diffusion and mass transfer

    CERN Document Server

    Vrentas, James S

    2013-01-01

    The book first covers the five elements necessary to formulate and solve mass transfer problems, that is, conservation laws and field equations, boundary conditions, constitutive equations, parameters in constitutive equations, and mathematical methods that can be used to solve the partial differential equations commonly encountered in mass transfer problems. Jump balances, Green’s function solution methods, and the free-volume theory for the prediction of self-diffusion coefficients for polymer–solvent systems are among the topics covered. The authors then use those elements to analyze a wide variety of mass transfer problems, including bubble dissolution, polymer sorption and desorption, dispersion, impurity migration in plastic containers, and utilization of polymers in drug delivery. The text offers detailed solutions, along with some theoretical aspects, for numerous processes including viscoelastic diffusion, moving boundary problems, diffusion and reaction, membrane transport, wave behavior, sedime...

  4. Research at the fragment mass analyser at ATLAS

    International Nuclear Information System (INIS)

    Davids, C.N.; Back, B.; Bearden, I.G.

    1993-01-01

    The experimental program at the Fragment Mass Analyzer (FMA) at the ATLAS heavy ion accelerator of the Argonne National Laboratory is described. The brief description and operational properties of the FMA are presented. The highest mass resolution obtained with the FMA is 525/1. Some experimental results are presented. 5 refs., 7 figs

  5. On systematic and statistic errors in radionuclide mass activity estimation procedure

    International Nuclear Information System (INIS)

    Smelcerovic, M.; Djuric, G.; Popovic, D.

    1989-01-01

    One of the most important requirements during nuclear accidents is the fast estimation of the mass activity of the radionuclides that suddenly and without control reach the environment. The paper points to systematic errors in the procedures of sampling, sample preparation and measurement itself, that in high degree contribute to total mass activity evaluation error. Statistic errors in gamma spectrometry as well as in total mass alpha and beta activity evaluation are also discussed. Beside, some of the possible sources of errors in the partial mass activity evaluation for some of the radionuclides are presented. The contribution of the errors in the total mass activity evaluation error is estimated and procedures that could possibly reduce it are discussed (author)

  6. Diagnosing impaired glucose tolerance using direct infusion mass spectrometry of blood plasma.

    Directory of Open Access Journals (Sweden)

    Petr G Lokhov

    Full Text Available The goal of this study was to evaluate the capacity for mass spectrometry of blood plasma to diagnose impaired glucose tolerance (IGT. For this study, blood plasma samples from control subjects (n = 30 and patients with IGT (n = 20 were treated with methanol and low molecular weight fraction were then analyzed by direct infusion mass spectrometry. A total of 51 metabolite ions strongly associated with IGT were detected. The area under a receiver operating characteristic (ROC curve (AUC for diagnosing IGT that was based on an analysis of all these metabolites was 0.93 (accuracy 90%, specificity 90%, and sensitivity 90%. The associated reproducibility was 85%. The metabolites identified were also consistent with risk factors previously associated with the development of diabetes. Thus, direct infusion mass spectrometry of blood plasma metabolites represents a rapid, single-step, and reproducible method for the analysis of metabolites. Moreover, this method has the potential to serve as a prototype for clinical analyses that could replace the currently used glucose tolerance test with a more patient-friendly assay.

  7. Ariadne: a database search engine for identification and chemical analysis of RNA using tandem mass spectrometry data.

    Science.gov (United States)

    Nakayama, Hiroshi; Akiyama, Misaki; Taoka, Masato; Yamauchi, Yoshio; Nobe, Yuko; Ishikawa, Hideaki; Takahashi, Nobuhiro; Isobe, Toshiaki

    2009-04-01

    We present here a method to correlate tandem mass spectra of sample RNA nucleolytic fragments with an RNA nucleotide sequence in a DNA/RNA sequence database, thereby allowing tandem mass spectrometry (MS/MS)-based identification of RNA in biological samples. Ariadne, a unique web-based database search engine, identifies RNA by two probability-based evaluation steps of MS/MS data. In the first step, the software evaluates the matches between the masses of product ions generated by MS/MS of an RNase digest of sample RNA and those calculated from a candidate nucleotide sequence in a DNA/RNA sequence database, which then predicts the nucleotide sequences of these RNase fragments. In the second step, the candidate sequences are mapped for all RNA entries in the database, and each entry is scored for a function of occurrences of the candidate sequences to identify a particular RNA. Ariadne can also predict post-transcriptional modifications of RNA, such as methylation of nucleotide bases and/or ribose, by estimating mass shifts from the theoretical mass values. The method was validated with MS/MS data of RNase T1 digests of in vitro transcripts. It was applied successfully to identify an unknown RNA component in a tRNA mixture and to analyze post-transcriptional modification in yeast tRNA(Phe-1).

  8. Nucleon axial form factors using Nf=2 twisted mass fermions with a physical value of the pion mass

    Science.gov (United States)

    Alexandrou, C.; Constantinou, M.; Hadjiyiannakou, K.; Jansen, K.; Kallidonis, C.; Koutsou, G.; Vaquero Aviles-Casco, A.

    2017-09-01

    We present results on the nucleon axial and induced pseudoscalar form factors using an ensemble of two degenerate twisted mass clover-improved fermions with mass yielding a pion mass of mπ=130 MeV . We evaluate the isovector and the isoscalar, as well as the strange and the charm axial form factors. The disconnected contributions are evaluated using recently developed methods that include deflation of the lower eigenstates, allowing us to extract the isoscalar, strange, and charm axial form factors. We find that the disconnected quark loop contributions are nonzero and particularly large for the induced pseudoscalar form factor.

  9. Stability evaluation considering the scattering of the physical properties of rock mass

    International Nuclear Information System (INIS)

    Ito, Hiroshi; Shin, Koichi

    1988-01-01

    The objective of this research is to establish the rational design method which could be evaluated the influence of the scattering of mechanical properties on the stability of the foundation ground of Nuclear Power Plant and surrounding slope. For this purpose, investigation on the actual scattering state of mechanical properties of rock and rock masses, and the stability estimations by the probabilistic method are conducted in this report, and following results are obtained. (1) The actual distribution of scattering of mechanical properties could describe in the probabilistic models of Weibull and Gamma distribution most accurately. The Normal distribution model could also do almostly. The coefficients of variation are so large in the range of 0.4 - 0.8, the remarkable tendency of them among the kinds of mechanical Properties and among the rock classification are not recognized. (2) It is found that the stability estimation considering the scattering of mechanical properties can be sufficiently conducted by using the conventional deterministic method, and the results of deterministic method using the average value of scattering need not be reduce in proportional to the degree of scattering of mechanical properties. (3) Based on these results, new rational design method and procedure, which could be evaluated the scattering of mechanical properties of ground material, is proposed. (author)

  10. Physical activity and dark skin tone: protective factors against low bone mass in Mexican men.

    Science.gov (United States)

    Vivanco-Muñoz, Nalleli; Jo, Talavera; Gerardo, Huitron-Bravo; Juan, Tamayo; Clark, Patricia

    2012-01-01

    A cross-sectional study was conducted on 268 Mexican men between the ages of 13 and 80 yr to evaluate the association of clinical factors related with bone mass. Men from high schools, universities, and retirement homes were invited to participate. Body mass index (BMI) was measured, and bone mineral density (BMD) was assessed using dual-energy X-ray absorptiometry for L1-L4 and total hip. Factors related to bone mass were assessed by questionnaire and analyzed using a logistic regression model. Demographic factors (age, education, and occupation), clinical data (BMI, skin tone, previous fracture, history of osteoporosis [OP], and history of fractures), and lifestyle variables (diet, physical activity, sun exposure, and smoking) were evaluated. Physical activity (≥ 60 min/5 times a week) reduced the risk for low BMD for age, osteopenia, and OP at the spine and total hip (odds ratio [OR]: 0.276; 95% confidence interval [CI]: 0.099-0.769; p=0.014; and OR: 0.184; 95% CI: 0.04-0.849; p=0.03, respectively). Dark skin tone was a protective factor, decreasing the risk by up to 70%. In this population of healthy Mexican men (aged 13-80 yr), dark skin and physical activity were protective factors against low bone mass. Copyright © 2012 The International Society for Clinical Densitometry. Published by Elsevier Inc. All rights reserved.

  11. microMS: A Python Platform for Image-Guided Mass Spectrometry Profiling

    Science.gov (United States)

    Comi, Troy J.; Neumann, Elizabeth K.; Do, Thanh D.; Sweedler, Jonathan V.

    2017-09-01

    Image-guided mass spectrometry (MS) profiling provides a facile framework for analyzing samples ranging from single cells to tissue sections. The fundamental workflow utilizes a whole-slide microscopy image to select targets of interest, determine their spatial locations, and subsequently perform MS analysis at those locations. Improving upon prior reported methodology, a software package was developed for working with microscopy images. microMS, for microscopy-guided mass spectrometry, allows the user to select and profile diverse samples using a variety of target patterns and mass analyzers. Written in Python, the program provides an intuitive graphical user interface to simplify image-guided MS for novice users. The class hierarchy of instrument interactions permits integration of new MS systems while retaining the feature-rich image analysis framework. microMS is a versatile platform for performing targeted profiling experiments using a series of mass spectrometers. The flexibility in mass analyzers greatly simplifies serial analyses of the same targets by different instruments. The current capabilities of microMS are presented, and its application for off-line analysis of single cells on three distinct instruments is demonstrated. The software has been made freely available for research purposes. [Figure not available: see fulltext.

  12. Adnexal mass in tubal pregnancy

    International Nuclear Information System (INIS)

    Lee, Hee Jung; Kim, Jung Sik; Chu, Yang Ku

    1993-01-01

    Off the evaluation of clinical significance and pathologic correlation of echogenic adnexal mass in tubal pregnancy, which is separated from ipsilateral ovary, we performed a retrospective analysis of 15 proved tubal pregnancies. All showed hematosalpinx containing blood coagulum and chorionic villi with intact fallopian tube.The echogenicity of the adnexal mass was considered to represent the nonclotted or clotted blood within the fallopian tube. We conclude that the discrete, echogenic adnexal mass is the suggestive finding of unrupturedtubal pregnancy

  13. Evaluation of the i-STAT Portable Clinical Analyzer for point-of-care blood testing in the intensive care units of a university children's hospital.

    Science.gov (United States)

    Papadea, Christine; Foster, Joyce; Grant, Sharon; Ballard, Sandra A; Cate, John C; Southgate, W Michael; Purohit, Dilip M

    2002-01-01

    We evaluated the analytical performance of the i-STAT Portable Clinical Analyzer (PCA), a point-of-care testing system consisting of a hand-held analyzer and single-use cartridges that measure different panels of electrolytes, metabolites, blood gases, and hematocrit in 65-100 microl of blood. Our objective was to determine whether PCA measurements at the bedside of patients in the neonatal and pediatric intensive care units of the MUSC Children's Hospital would be as reliable as those performed by the clinical laboratory's primary methods (Radiometer ABL 725 blood gas analyzer; Vitros 750 chemistry analyzer; and Coulter STKS hematology analyzer). Four cartridge types: (a) EC8+ (sodium; potassium; chloride; urea; glucose; pH; blood gases [PO2; pCO2]), (b) EC6+ (sodium; potassium; ionized calcium; glucose; hematocrit; pH), (c) G3+ (pH; PO2; pCO2), and (d) creatinine, were assessed for reproducibility, linearity, and method comparisons using aqueous samples, blood samples supplemented with several analytes, and -225 blood samples from patients. Reproducibility (CV) was good ( or < 3 mo) showed that agreement between the PCA and the primary methods was clinically acceptable. After the PCA was implemented for clinical testing, the observation of discrepant results of creatinine concentrations in neonatal blood samples that would have affected clinical management led to a second creatinine comparison study (59 additional samples) and to our eventual discontinuation of the PCA creatinine assay. This problem notwithstanding, the successful implementation of the PCA is attributed to careful analytical evaluations and ongoing communication with the clinical staff.

  14. Mass estimates from stellar proper motions: the mass of ω Centauri

    Science.gov (United States)

    D'Souza, Richard; Rix, Hans-Walter

    2013-03-01

    We lay out and apply methods to use proper motions of individual kinematic tracers for estimating the dynamical mass of star clusters. We first describe a simple projected mass estimator and then develop an approach that evaluates directly the likelihood of the discrete kinematic data given the model predictions. Those predictions may come from any dynamical modelling approach, and we implement an analytic King model, a spherical isotropic Jeans equation model and an axisymmetric, anisotropic Jeans equation model. This maximum likelihood modelling (MLM) provides a framework for a model-data comparison, and a resulting mass estimate, which accounts explicitly for the discrete nature of the data for individual stars, the varying error bars for proper motions of differing signal-to-noise ratio, and for data incompleteness. Both of these two methods are evaluated for their practicality and are shown to provide an unbiased and robust estimate of the cluster mass. We apply these approaches to the enigmatic globular cluster ω Centauri, combining the proper motion from van Leeuwen et al. with improved photometric cluster membership probabilities. We show that all mass estimates based on spherical isotropic models yield (4.55 ± 0.1) × 106 M⊙[D/5.5 ± 0.2 kpc]3, where our modelling allows us to show how the statistical precision of this estimate improves as more proper motion data of lower signal-to-noise ratio are included. MLM predictions, based on an anisotropic axisymmetric Jeans model, indicate for ω Cen that the inclusion of anisotropies is not important for the mass estimates, but that accounting for the flattening is: flattened models imply (4.05 ± 0.1) × 106 M⊙[D/5.5 ± 0.2 kpc]3, 10 per cent lower than when restricting the analysis to a spherical model. The best current distance estimates imply an additional uncertainty in the mass estimate of 12 per cent.

  15. Mass Analyzers Facilitate Research on Addiction

    Science.gov (United States)

    2012-01-01

    The famous go/no go command for Space Shuttle launches comes from a place called the Firing Room. Located at Kennedy Space Center in the Launch Control Center (LCC), there are actually four Firing Rooms that take up most of the third floor of the LCC. These rooms comprise the nerve center for Space Shuttle launch and processing. Test engineers in the Firing Rooms operate the Launch Processing System (LPS), which is a highly automated, computer-controlled system for assembly, checkout, and launch of the Space Shuttle. LPS monitors thousands of measurements on the Space Shuttle and its ground support equipment, compares them to predefined tolerance levels, and then displays values that are out of tolerance. Firing Room operators view the data and send commands about everything from propellant levels inside the external tank to temperatures inside the crew compartment. In many cases, LPS will automatically react to abnormal conditions and perform related functions without test engineer intervention; however, firing room engineers continue to look at each and every happening to ensure a safe launch. Some of the systems monitored during launch operations include electrical, cooling, communications, and computers. One of the thousands of measurements derived from these systems is the amount of hydrogen and oxygen inside the shuttle during launch.

  16. Multivariate analytical figures of merit as a metric for evaluation of quantitative measurements using comprehensive two-dimensional gas chromatography-mass spectrometry.

    Science.gov (United States)

    Eftekhari, Ali; Parastar, Hadi

    2016-09-30

    The present contribution is devoted to develop multivariate analytical figures of merit (AFOMs) as a new metric for evaluation of quantitative measurements using comprehensive two-dimensional gas chromatography-mass spectrometry (GC×GC-MS). In this regard, new definition of sensitivity (SEN) is extended to GC×GC-MS data and then, other multivariate AFOMs including analytical SEN (γ), selectivity (SEL) and limit of detection (LOD) are calculated. Also, two frequently used second- and third-order calibration algorithms of multivariate curve resolution-alternating least squares (MCR-ALS) as representative of multi-set methods and parallel factor analysis (PARAFAC) as representative of multi-way methods are discussed to exploit pure component profiles and to calculate multivariate AFOMs. Different GC×GC-MS data sets with different number of components along with various levels of artifacts are simulated and analyzed. Noise, elution time shifts in both chromatographic dimensions, peak overlap and interferences are considered as the main artifacts in this work. Additionally, a new strategy is developed to estimate the noise level using variance-covariance matrix of residuals which is very important to calculate multivariate AFOMs. Finally, determination of polycyclic aromatic hydrocarbons (PAHs) in aromatic fraction of heavy fuel oil (HFO) analyzed by GC×GC-MS is considered as real case to confirm applicability of the proposed metric in real samples. It should be pointed out that the proposed strategy in this work can be used for other types of comprehensive two-dimensional chromatographic (CTDC) techniques like comprehensive two dimensional liquid chromatography (LC×LC). Copyright © 2016 Elsevier B.V. All rights reserved.

  17. On Estimating the Mass of Keplerian Accretion Disks in H2O Maser Galaxies

    Science.gov (United States)

    Kuo, C. Y.; Reid, M. J.; Braatz, J. A.; Gao, F.; Impellizzeri, C. M. V.; Chien, W. T.

    2018-06-01

    H2O maser disks with Keplerian rotation in active galactic nuclei offer a clean way to determine accurate black hole mass and the Hubble constant. An important assumption made in using a Keplerian H2O maser disk for measuring black hole mass and the Hubble constant is that the disk mass is negligible compared to the black hole mass. A simple and useful model of Huré et al. can be used to test this assumption. In that work, the authors apply a linear disk model to a position–dynamical mass diagram and re-analyze position–velocity data from H2O maser disks associated with active galactic nuclei. They claim that a maser disk with nearly perfect Keplerian rotation could have a disk mass comparable to the black hole mass. This would imply that ignoring the effects of disk self-gravity can lead to large systematic errors in the measurement of black hole mass and the Hubble constant. We examine their methods and find that their large estimated disk masses of Keplerian disks are likely the result of their use of projected instead of three-dimensional position and velocity information. To place better constraints on the disk masses of Keplerian maser systems, we incorporate disk self-gravity into a three-dimensional Bayesian modeling program for maser disks and also evaluate constraints based on the physical conditions for disks that support water maser emission. We find that there is little evidence that disk masses are dynamically important at the ≲1% level compared to the black holes.

  18. Development of remote controlled electron probe micro analyzer with crystal orientation analyzer

    International Nuclear Information System (INIS)

    Honda, Junichi; Matsui, Hiroki; Harada, Akio; Obata, Hiroki; Tomita, Takeshi

    2012-07-01

    The advanced utilization of Light Water Reactor (LWR) fuel is progressed in Japan to save the power generating cost and the volume of nuclear wastes. The electric power companies have continued the approach to the burnup extension and to rise up the thermal power increase of the commercial fuel. The government should be accumulating the detailed information on the newest technologies to make the regulations and guidelines for the safety of the advanced nuclear fuels. The remote controlled Electron Probe Micro Analyzer (EPMA) attached with crystal orientation analyzer has been developed in Japan Atomic Energy Agency (JAEA) to study the fuel behavior of the high burnup fuels under the accident condition. The effects of the cladding microstructure on the fuel behavior will be evaluated more conveniently and quantitatively by this EPMA. The commercial model of EPMA has been modified to have the performance of airtight and earthquake resistant in compliance with the safety regulation by the government for handling the high radioactive elements. This paper describes the specifications of EPMA which were specialised for post irradiation examination and the test results of the cold mock-up to confirm their performances and reliabilities. (author)

  19. Coherent Network Optimizing of Rail-Based Urban Mass Transit

    Directory of Open Access Journals (Sweden)

    Ying Zhang

    2012-01-01

    Full Text Available An efficient public transport is more than ever a crucial factor when it comes to the quality of life and competitiveness of many cities and regions in Asia. In recent years, the rail-based urban mass transit has been regarded as one of the key means to overcoming the great challenges in Chinese megacities. The purpose of this study is going to develop a coherent network optimizing for rail-based urban mass transit to find the best alternatives for the user and to demonstrate how to meet sustainable development needs and to match the enormous capacity requirements simultaneously. This paper presents an introduction to the current situation of the important lines, and transfer points in the metro system Shanghai. The insufficient aspects are analyzed and evaluated; while the optimizing ideas and measurements are developed and concreted. A group of examples are used to illustrate the approach. The whole study could be used for the latest reference for other megacities which have to be confronted with the similar situations and processes with enormous dynamic travel and transport demands.

  20. Atomic mass spectrometry

    International Nuclear Information System (INIS)

    Sanz-Medel, A.

    1997-01-01

    The elemental inorganic analysis seems to be dominated today by techniques based on atomic spectrometry. After an evaluation of advantages and limitations of using mass analysers (ion detectors) versus conventional photomultipliers (photon detector) a brief review of the more popular techniques of the emerging Atomic Mass spectrometry is carried out. Their huge potential for inorganic trace analysis is such that in the future we could well witness how this end of the century and millennium marked the fall of the photons empire in Analytical Atomic Spectrometry. (Author)

  1. Evaluation of colorimetric assays for analyzing reductively methylated proteins: Biases and mechanistic insights.

    Science.gov (United States)

    Brady, Pamlea N; Macnaughtan, Megan A

    2015-12-15

    Colorimetric protein assays, such as the Coomassie blue G-250 dye-binding (Bradford) and bicinchoninic acid (BCA) assays, are commonly used to quantify protein concentration. The accuracy of these assays depends on the amino acid composition. Because of the extensive use of reductive methylation in the study of proteins and the importance of biological methylation, it is necessary to evaluate the impact of lysyl methylation on the Bradford and BCA assays. Unmodified and reductively methylated proteins were analyzed using the absorbance at 280 nm to standardize the concentrations. Using model compounds, we demonstrate that the dimethylation of lysyl ε-amines does not affect the proteins' molar extinction coefficients at 280 nm. For the Bradford assay, the responses (absorbance per unit concentration) of the unmodified and reductively methylated proteins were similar, with a slight decrease in the response upon methylation. For the BCA assay, the responses of the reductively methylated proteins were consistently higher, overestimating the concentrations of the methylated proteins. The enhanced color formation in the BCA assay may be due to the lower acid dissociation constants of the lysyl ε-dimethylamines compared with the unmodified ε-amine, favoring Cu(II) binding in biuret-like complexes. The implications for the analysis of biologically methylated samples are discussed. Copyright © 2015 Elsevier Inc. All rights reserved.

  2. The project of the mass separator of atomic nuclei produced in heavy ion induced reactions

    CERN Document Server

    Oganessian, Yu T; Dmitriev, S N; Itkis, M G; Gulbekyan, G G; Khabarov, M V; Bekhterev, V V; Bogomolov, S L; Efremov, A A; Pashenko, S V; Stepantsov, S V; Yeremin, A V; Yavor, M I; Kalimov, A G

    2003-01-01

    A new separator and mass analyzer, named MASHA (mass analyzer of super heavy atoms), has been designed at the Flerov Laboratory JINR Dubna to separate and measure masses of nuclei and molecules with precision better than 10 sup - sup 3. The set up can work in the wide mass range from A approx 20 to A approx 500, its mass acceptance is as large as +-2.8%. In particular, it allows unambiguous mass identification of super heavy nuclei with a resolution better than 1 amu at the level of 300 amu. Synthesized in nuclear reactions nuclides are emitted from an ECR ion source at energy E=40 kV and charge state Q=+1. Then they pass the following steps of separation and analysis: the first section of rough separation, the second section of separation and mass analysis and the final section of separation with a 90 deg. electrostatic deflector. In the focal plane of the device, a focal plane detector determines positions (masses) of studied nuclei. Ion optics of the analyzer, optimized up to the second order, is considere...

  3. Performance assessment of mass flow rate measurement capability in a large scale transient two-phase flow test system

    International Nuclear Information System (INIS)

    Nalezny, C.L.; Chapman, R.L.; Martinell, J.S.; Riordon, R.P.; Solbrig, C.W.

    1979-01-01

    Mass flow is an important measured variable in the Loss-of-Fluid Test (LOFT) Program. Large uncertainties in mass flow measurements in the LOFT piping during LOFT coolant experiments requires instrument testing in a transient two-phase flow loop that simulates the geometry of the LOFT piping. To satisfy this need, a transient two-phase flow loop has been designed and built. The load cell weighing system, which provides reference mass flow measurements, has been analyzed to assess its capability to provide the measurements. The analysis consisted of first performing a thermal-hydraulic analysis using RELAP4 to compute mass inventory and pressure fluctuations in the system and mass flow rate at the instrument location. RELAP4 output was used as input to a structural analysis code SAPIV which is used to determine load cell response. The computed load cell response was then smoothed and differentiated to compute mass flow rate from the system. Comparison between computed mass flow rate at the instrument location and mass flow rate from the system computed from the load cell output was used to evaluate mass flow measurement capability of the load cell weighing system. Results of the analysis indicate that the load cell weighing system will provide reference mass flows more accurately than the instruments now in LOFT

  4. One Sample, One Shot - Evaluation of sample preparation protocols for the mass spectrometric proteome analysis of human bile fluid without extensive fractionation.

    Science.gov (United States)

    Megger, Dominik A; Padden, Juliet; Rosowski, Kristin; Uszkoreit, Julian; Bracht, Thilo; Eisenacher, Martin; Gerges, Christian; Neuhaus, Horst; Schumacher, Brigitte; Schlaak, Jörg F; Sitek, Barbara

    2017-02-10

    The proteome analysis of bile fluid represents a promising strategy to identify biomarker candidates for various diseases of the hepatobiliary system. However, to obtain substantive results in biomarker discovery studies large patient cohorts necessarily need to be analyzed. Consequently, this would lead to an unmanageable number of samples to be analyzed if sample preparation protocols with extensive fractionation methods are applied. Hence, the performance of simple workflows allowing for "one sample, one shot" experiments have been evaluated in this study. In detail, sixteen different protocols implying modifications at the stages of desalting, delipidation, deglycosylation and tryptic digestion have been examined. Each method has been individually evaluated regarding various performance criteria and comparative analyses have been conducted to uncover possible complementarities. Here, the best performance in terms of proteome coverage has been assessed for a combination of acetone precipitation with in-gel digestion. Finally, a mapping of all obtained protein identifications with putative biomarkers for hepatocellular carcinoma (HCC) and cholangiocellular carcinoma (CCC) revealed several proteins easily detectable in bile fluid. These results can build the basis for future studies with large and well-defined patient cohorts in a more disease-related context. Human bile fluid is a proximal body fluid and supposed to be a potential source of disease markers. However, due to its biochemical composition, the proteome analysis of bile fluid still represents a challenging task and is therefore mostly conducted using extensive fractionation procedures. This in turn leads to a high number of mass spectrometric measurements for one biological sample. Considering the fact that in order to overcome the biological variability a high number of biological samples needs to be analyzed in biomarker discovery studies, this leads to the dilemma of an unmanageable number of

  5. The Effect of Freezing and Hydrocolloids on the Physical Parameters of Strawberry Mass-Based Desserts

    Directory of Open Access Journals (Sweden)

    Boča Sigita

    2014-07-01

    Full Text Available The aim of the study was to evaluate the effect of freezing, thickening and storage on the physical properties of the strawberry desserts made with addition of various hydrocolloids. The strawberry cultivars ‘Polka’, ‘Honeoye’, and ‘Senga Sengana’ harvested in Latvia were used in the study. The strawberries were processed in a blender for obtaining a homogenous mass. The strawberry mass was analyzed fresh and after storage at -18 °C. Both fresh and frozen strawberry mass samples with added gelatine, xanthan gum, and sodium carboxymethyl cellulose were whisked until obtaining dessert. For determination of the optimum hydrocolloid amount, sensory evaluation was done using a five-point hedonic scale. Moisture, soluble solids content, density, and pH of the product were determined. Apparent viscosity was measured using a rotational viscometer DV–III Ultra. Consistency of the dessert during its storage was evaluated using a texture analyser TA.XT.plus. The results of sensory evaluation allow concluding that in order to provide the most acceptable consistency, colour, and taste of strawberry dessert, the optimum quantity of carboxymethyl cellulose and xanthan gum to be added is 0.6% and that of gelatine is 6%. During freezing, the soluble solids content and pH level decreased in the strawberry mass, whereas the addition of hydrocolloids increased these values. The moisture content in strawberry puree, in its turn, as a result of freezing increased under the influence of syneresis, but added hydrocolloids, on the contrary, decreased this influence. Also the viscosity and consistency of the strawberry puree prepared from the researched cultivars decreased under the influence of freezing, whereas the addition of hydrocolloids increased both the values, making the strawberry dessert firmer. The research suggests that strawberry dessert with gelatine had the most pronounced changes during storage, but strawberry dessert with added xanthan

  6. Multi-site, multi-country evaluation of analytical and operational performance of a low-mid volume chemiluminescent immunoassay analyzer.

    Science.gov (United States)

    De Keijzer, M H; Perkins, S; Motta, V; Morelli, D; Cristol, J P; Dupuy, A M; Hong, Y; Watanabe, S; Waerdt, C; Grunewald, R W

    2009-01-01

    A new automated immunoassay low-mid volume (beta-hCG, BNP, and CK-MB) and the time required to complete workloads of 50 and 100 tests with a mixture of 75% routine tests and 25% stat tests was also evaluated. Total precision was typically market and in use for an existing high volume immunoassay system. Stat turn around times were consistent with the fixed analytical time of 15.6 minutes and met the expectations of the laboratories. Measured test throughput ranged from 47 - 54 tests per hour and demonstrated that the analyzer was fit for the intended purpose of supporting a laboratory that performs suitable for use.

  7. [EXPRESS IDENTIFICATION OF POSITIVE BLOOD CULTURES USING DIRECT MALDI-TOF MASS SPECTROMETRY].

    Science.gov (United States)

    Popov, D A; Ovseenko, S T; Vostrikova, T Yu

    2015-01-01

    To evaluate the effectiveness of direct identification of pathogens of bacteremia by direct matrix assisted laser desorption ionization time-flight mass spectrometry (mALDI-TOF) compared to routine method. A prospective study included 211 positive blood cultures obtained from 116 patients (106 adults and 10 children, aged from 2 weeks to 77 years old in the ICU after open heart surgery. Incubation was carried out under aerobic vials with a sorbent for antibiotics Analyzer BacT/ALERT 3D 120 (bioMerieux, France) in parallel with the primary sieving blood cultures on solid nutrient media with subsequent identification of pure cultures using MALDI-TOF mass spectrometry analyzer Vitek MS, bioMerieux, France routine method), after appropriate sample preparation we carried out a direct (without screening) MALDI-TOF mass spectrometric study of monocomponental blood cultures (n = 201). using a routine method in 211 positive blood cultures we identified 23 types of microorganisms (Staphylococcus (n = 87), Enterobacteria- ceae (n = 71), Enterococci (n = 20), non-fermentative Gram-negative bacteria (n = 18), others (n = 5). The average time of incubation of samples to obtain a signal of a blood culture growth was 16.2 ± 7.4 h (from 3.75 to 51 hours.) During the first 12 hours of incubation, growth was obtained in 32.4% of the samples, and on the first day in 92.2%. In the direct mass spectrometric analysis mnonocomponental blood cultures (n = 201) is well defined up to 153 species of the sample (76.1%), while the share of successful identification of Gram-negative bacteria was higher than that of Gram-positive (85.4 and 69, 1%, respectively p = 0.01). The high degree of consistency in the results of standard and direct method of identifying blood cultures using MALDI-TOF mass spectrometry (κ = 0.96, p direct mass spectrometric analysis, including sample preparation, was no longer than 1 hour: The method of direct MALDI-TOF mass spectrometry allows to significantly speed up

  8. Semi-continuous on-line uranium ore analyzer

    International Nuclear Information System (INIS)

    Campbell, P.; Gurdy, E.M.; Hatchowski, L.

    1984-01-01

    The efficient process control of a uranium mill and its associated mining operation requires a nearly continuous knowledge of the uranium concentration in the ore. Generally, the approach is to use laboratory assays of grab samples from the mill feed belt. In some cases, elaborate and expensive systems have been used to ensure random sampling, but even with these systems, mass-balance discrepancies still exist. There is a requirement for an on-line instrument that can give a prompt, accurate analysis of a large portion of the feed stock. The authors have recently evaluated a laboratory system that achieves these goals using neutron activation and delayed neutron counting. The development of the on-line uranium ore analyzer is a consequence of previous work done at the Whiteshell Nuclear Research Establishment (WNRE) (Campbell et al., 1978 and 1981), and is based on the emission of delayed neutrons after the neutron irradiation of fissionable materials. The mechanism of delayed neutron emission has been described (Keepin, 1965), but briefly is as follows. The fission fragments resulting from irradiation are in an excited state. Certain of these delayed fission products, precursors, decay to a more stable state by the emission of a delayed neutron. The delayed neutrons can be divided into six groups with effective half-lives ranging from 0.2-55 sec. It is important to note that more than 50% of the delayed neutrons are emitted within the first 6 sec after irradiation; this has an influence on the design of the analysis instrument

  9. Performance evaluation of indigenous thermal ionization mass spectrometer for determination of 235U/238U atom ratios

    International Nuclear Information System (INIS)

    Alamelu, D.; Parab, A.R.; Sasi Bhushan, K.; Shah, Raju V.; Jagdish Kumar, S.; Rao, Radhika M.; Aggarwal, S.K.; Bhatia, R.K.; Yadav, V.K.; Sharma, Madhavi P.; Tulsyan, Puneet; Chavda, Pradip; Sriniwasan, P.

    2014-07-01

    A magnetic sector based Thermal Ionization Mass Spectrometer (TIMS) designed and developed at Technical Physics Division, B.A.R.C., was evaluated for its performance for the determination of 235 U/ 238 U atom ratios in uranium samples. This consisted of evaluating the precision and accuracy on the 235 U/ 238 U atom ratios in various isotopic reference materials as well as indigenously generated uranium samples. The results obtained by the indigenous TIMS were also compared with those obtained using a commercially available TIMS system. The internal and external precision were found to be around 0.1% for determining 235 U/ 238 U atom ratios close to those of natural uranium ( i.e. 0.00730). (author)

  10. Evaluation of mass transport property using natural uranium-series and thorium-series nuclides in the Toki Granite

    International Nuclear Information System (INIS)

    Hama, Katsuhiro

    2016-07-01

    The Mizunami Underground Research Laboratory (MIU) project is being pursued by the Japan Atomic Energy Agency (JAEA) to enhance the reliability of relevant disposal technologies through investigations of the deep geological environment within the host crystalline rock at Mizunami City in Gifu Prefecture, central Japan. The project proceeds in three overlapping phases, 'Phase I: Surface-based investigation Phase', 'Phase II: Construction Phase' and 'Phase III: Operation Phase'. As a part of the Phase III investigation, the mass transport property has been evaluated by using natural uranium-series and thorium-series nuclides in the Toki Granite. In this report, the compilation of existing data and preliminary evaluation was carried out. (author)

  11. The neutron star mass distribution

    Energy Technology Data Exchange (ETDEWEB)

    Kiziltan, Bülent [Harvard-Smithsonian Center for Astrophysics, 60 Garden Street, Cambridge, MA 02138 (United States); Kottas, Athanasios; De Yoreo, Maria [Department of Applied Mathematics and Statistics, University of California, Santa Cruz, CA 95064 (United States); Thorsett, Stephen E., E-mail: bkiziltan@cfa.harvard.edu [Department of Astronomy and Astrophysics, University of California and UCO/Lick Observatory, Santa Cruz, CA 95064 (United States)

    2013-11-20

    In recent years, the number of pulsars with secure mass measurements has increased to a level that allows us to probe the underlying neutron star (NS) mass distribution in detail. We critically review the radio pulsar mass measurements. For the first time, we are able to analyze a sizable population of NSs with a flexible modeling approach that can effectively accommodate a skewed underlying distribution and asymmetric measurement errors. We find that NSs that have evolved through different evolutionary paths reflect distinctive signatures through dissimilar distribution peak and mass cutoff values. NSs in double NS and NS-white dwarf (WD) systems show consistent respective peaks at 1.33 M {sub ☉} and 1.55 M {sub ☉}, suggesting significant mass accretion (Δm ≈ 0.22 M {sub ☉}) has occurred during the spin-up phase. The width of the mass distribution implied by double NS systems is indicative of a tight initial mass function while the inferred mass range is significantly wider for NSs that have gone through recycling. We find a mass cutoff at ∼2.1 M {sub ☉} for NSs with WD companions, which establishes a firm lower bound for the maximum NS mass. This rules out the majority of strange quark and soft equation of state models as viable configurations for NS matter. The lack of truncation close to the maximum mass cutoff along with the skewed nature of the inferred mass distribution both enforce the suggestion that the 2.1 M {sub ☉} limit is set by evolutionary constraints rather than nuclear physics or general relativity, and the existence of rare supermassive NSs is possible.

  12. Three-dimensional Mass Measurement of Subsolid Pulmonary Nodules on Chest CT: Intra and Inter-observer Variability

    Directory of Open Access Journals (Sweden)

    Huiting LIU

    2015-05-01

    Full Text Available Background and objective Subsolid pulmonary nodules tend to exhibit considerably slower growth rates than solid lesions, nevertheless, higher malignancy probability. The diagnosis of indeterminate nodules largely depends on the growth evaluation during follow-up. The growth can manifested as an increase in size or the appearance and/or subsequent increase of solid components. The mass reflect the product of volume and density and can be more sensitive in growth evaluation. However, the repeatability needs a further validation. The purpose of this study is to assess the intra and inter-observer variability of mass measurement for subsolid nodules. Methods 80 subsolid nodules in 44 patients were retrospectively enrolled. Both the volume and mass were measured by two radiologists using blind method independently. Intra-observer and inter-observer variability were analyzed and compared by Bland-Altman method intra-class correlation test and Wilcoxon test. Results Software achieved satisfied segmentation for 92.5% nodules. Of them, 35% underwent manual modification. The 95% limits of agreement for intra-observer variability were -11.5%-10.4% for mass and -8.4%-8.8% for volume. The 95% limits of agreement for inter-observer variability were -17.4%-19.3% for mass and -17.9%-19.4% for volume.The intra-class correlation foefficients between volume and mass measument was 0.95 and 0.93 (both P<0.001 and no significant differences (P=0.78, 0.09 was found for intra- and inter-observer variability. Manual modification of the segmentation caused the worse mass measurement repeatability in spite of the reader satisfaction. Conclusion The repeatability of mass measurement has no significant difference with that of volume measurement and may act as a reliable method in the follow-up of subsolid nodules.

  13. A comprehensive high-resolution mass spectrometry approach for characterization of metabolites by combination of ambient ionization, chromatography and imaging methods.

    Science.gov (United States)

    Berisha, Arton; Dold, Sebastian; Guenther, Sabine; Desbenoit, Nicolas; Takats, Zoltan; Spengler, Bernhard; Römpp, Andreas

    2014-08-30

    An ideal method for bioanalytical applications would deliver spatially resolved quantitative information in real time and without sample preparation. In reality these requirements can typically not be met by a single analytical technique. Therefore, we combine different mass spectrometry approaches: chromatographic separation, ambient ionization and imaging techniques, in order to obtain comprehensive information about metabolites in complex biological samples. Samples were analyzed by laser desorption followed by electrospray ionization (LD-ESI) as an ambient ionization technique, by matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging for spatial distribution analysis and by high-performance liquid chromatography/electrospray ionization mass spectrometry (HPLC/ESI-MS) for quantitation and validation of compound identification. All MS data were acquired with high mass resolution and accurate mass (using orbital trapping and ion cyclotron resonance mass spectrometers). Grape berries were analyzed and evaluated in detail, whereas wheat seeds and mouse brain tissue were analyzed in proof-of-concept experiments. In situ measurements by LD-ESI without any sample preparation allowed for fast screening of plant metabolites on the grape surface. MALDI imaging of grape cross sections at 20 µm pixel size revealed the detailed distribution of metabolites which were in accordance with their biological function. HPLC/ESI-MS was used to quantify 13 anthocyanin species as well as to separate and identify isomeric compounds. A total of 41 metabolites (amino acids, carbohydrates, anthocyanins) were identified with all three approaches. Mass accuracy for all MS measurements was better than 2 ppm (root mean square error). The combined approach provides fast screening capabilities, spatial distribution information and the possibility to quantify metabolites. Accurate mass measurements proved to be critical in order to reliably combine data from different MS

  14. Textbooks in the EFL classroom: Defining, assessing and analyzing

    Directory of Open Access Journals (Sweden)

    Radić-Bojanić Biljana B.

    2016-01-01

    Full Text Available The aim of this paper is to define textbooks, analyze their advantages and disadvantages and to explicate the process of textbook selection and reasons for analyzing textbooks. The paper describes two reasons for performing a textbook analysis: evaluating for potential and evaluating for suitability, and further states various processes of textbook content analysis including the analysis of the stated aims and objectives, learner needs, their abilities and preferences, as well as the establishment of criteria in relation to previously set objectives. The paper concludes by stating that the task that teachers are faced with when selecting and evaluating textbooks is not that is an easy one, but it is crucial. With the assistance of clear guidelines and detailed criteria, they should be able to make an informed decision and choose a textbook that is most suitable for the requirements of their specific classroom context.

  15. Review of atomic mass formula

    Energy Technology Data Exchange (ETDEWEB)

    Tachibana, Takahiro [Waseda Univ., Tokyo (Japan). Advanced Research Center for Science and Engineering

    1997-07-01

    Wapstra and Audi`s Table is famous for evaluation of experimental data of atomic nuclear masses (1993/1995 version) which estimated about 2000 kinds of nuclei. The error of atomic mass of formula is 0.3 MeV-0.8 MeV. Four kinds of atomic mass formula: JM (Jaenecke and Masson), TUYY (Tachibana, Uno, Yamada and Yamada), FRDM (Moeller, Nix, Myers and Swiatecki) and ETFSI (Aboussir, Pearson, Dutta and Tondeur) and their properties (number of parameter and error etc.) were explained. An estimation method of theoretical error of mass formula was presented. It was estimated by the theoretical error of other surrounding nuclei. (S.Y.)

  16. Forensic Mass Spectrometry

    Science.gov (United States)

    Hoffmann, William D.; Jackson, Glen P.

    2015-07-01

    Developments in forensic mass spectrometry tend to follow, rather than lead, the developments in other disciplines. Examples of techniques having forensic potential born independently of forensic applications include ambient ionization, imaging mass spectrometry, isotope ratio mass spectrometry, portable mass spectrometers, and hyphenated chromatography-mass spectrometry instruments, to name a few. Forensic science has the potential to benefit enormously from developments that are funded by other means, if only the infrastructure and personnel existed to adopt, validate, and implement the new technologies into casework. Perhaps one unique area in which forensic science is at the cutting edge is in the area of chemometrics and the determination of likelihood ratios for the evaluation of the weight of evidence. Such statistical techniques have been developed most extensively for ignitable-liquid residue analyses and isotope ratio analysis. This review attempts to capture the trends, motivating forces, and likely impact of developing areas of forensic mass spectrometry, with the caveat that none of this research is likely to have any real impact in the forensic community unless: (a) The instruments developed are turned into robust black boxes with red and green lights for positives and negatives, respectively, or (b) there are PhD graduates in the workforce who can help adopt these sophisticated techniques.

  17. [Evaluation of mass spectrometry: MALDI-TOF MS for fast and reliable yeast identification].

    Science.gov (United States)

    Relloso, María S; Nievas, Jimena; Fares Taie, Santiago; Farquharson, Victoria; Mujica, María T; Romano, Vanesa; Zarate, Mariela S; Smayevsky, Jorgelina

    2015-01-01

    The matrix-assisted laser desorption/ionization time-of-flight mass spectrometry technique known as MALDI-TOF MS is a tool used for the identification of clinical pathogens by generating a protein spectrum that is unique for a given species. In this study we assessed the identification of clinical yeast isolates by MALDI-TOF MS in a university hospital from Argentina and compared two procedures for protein extraction: a rapid method and a procedure based on the manufacturer's recommendations. A short protein extraction procedure was applied in 100 isolates and the rate of correct identification at genus and species level was 98.0%. In addition, we analyzed 201 isolates, previously identified by conventional methods, using the methodology recommended by the manufacturer and there was 95.38% coincidence in the identification at species level. MALDI TOF MS showed to be a fast, simple and reliable tool for yeast identification. Copyright © 2014 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. Technicolor and the asymptotic behavior of dynamically generated masses

    International Nuclear Information System (INIS)

    Natale, A.A.

    1984-01-01

    Arguments are given in favor of a hard asymptotic behavior of dynamically generated masses, its consequences for technicolor models are analyzed and a model is proposed, where effects of flavor changing neutral currents are highly supressed and pseudo Goldstone bosons get masses of O(30-90) GeV. (Author) [pt

  19. TEM Imaging of Mass-selected Polymer Molecules

    International Nuclear Information System (INIS)

    Nasibulin, Albert G.; Kauppinen, Esko I.; Thomson, Bruce A.; Fernandez de la Mora, J.

    2002-01-01

    Polyethylene glycol (PEG) molecules with masses below 1300 amu are electrosprayed (ES) from solution, mobility-selected at high resolution in a differential mobility analyzer (DMA), collected on a grid and imaged by transmission electron microscopy (ES-DMA-TEM). The DMA resolves individual n-mers, and selects only one out of the many present in the original sample. Ion identity is established from parallel mass spectra (ES-MS). The images reveal spherical particles 1.46 nm in diameter, in good agreement with the known ion mass and bulk density. The DMA-selection technique opens new paths for the study of very small particles

  20. Multimodality imaging of placental masses: a pictorial review.

    Science.gov (United States)

    Jha, Priyanka; Paroder, Viktoriya; Mar, Winnie; Horowtiz, Jeanne M; Poder, Liina

    2016-12-01

    Placental masses are uncommonly identified at the time of obstetric ultrasound evaluation. Understanding the pathologies presenting as placental masses is key for providing a differential diagnosis and guiding subsequent management, which may include additional imaging with magnetic resonance (MR) imaging. Potential benign entities include chorioangiomas and teratomas. Larger chorioangiomas can cause fetal cardiovascular issues from volume overload. Placental mesenchymal dysplasia has an association with fetal anomalies and detailed fetal evaluation should be performed when it is suspected. Identifying other cystic masses such as partial and complete moles is crucial to prevent erroneous pregnancy termination. This review addresses normal imaging appearance of the placenta on ultrasound and MR imaging and describes various trophoblastic and nontrophoblastic placental masses. Potential placental mass mimics including uterine contractions and thrombo-hematomas are also presented.

  1. AmAMorph: Finite State Morphological Analyzer for Amazighe

    Directory of Open Access Journals (Sweden)

    Fatima Zahra Nejme

    2016-03-01

    Full Text Available This paper presents AmAMorph, a morphological analyzer for Amazighe language using a system based on the NooJ linguistic development environment. The paper begins with the development of Amazighe lexicons with large coverage formalization. The built electronic lexicons, named ‘NAmLex’, ‘VAmLex’ and ‘PAmLex’ which stand for ‘Noun Amazighe Lexicon’, ‘Verb Amazighe Lexicon’ and ‘Particles Amazighe Lexicon’, link inflectional, morphological, and syntacticsemantic information to the list of lemmas. Automated inflectional and derivational routines are applied to each lemma producing over inflected forms. To our knowledge,AmAMorph is the first morphological analyzer for Amazighe. It identifies the component morphemes of the forms using large coverage morphological grammars. Along with the description of how the analyzer is implemented, this paper gives an evaluation of the analyzer.

  2. Relation of body mass index and body fat mass for Spanish university students, taking into account leisure-time physical activity.

    Science.gov (United States)

    Molina-García, Javier; Castillo, Isabel; Pablos, Carlos; Queralt, Ana

    2009-04-01

    The objective of this cross-sectional study was to analyze the relation of Body Mass Index with body fat mass while taking into account the amount of leisure-time physical activity for 299 male university students. Body fat mass was measured by bioelectrical impedance analysis. An estimation of energy expenditure in leisure-time physical activity in metabolic equivalents (METs) was obtained so participants were divided into six activity groups by percentile: no physical activity by the first group and participants physically active were divided into five groups by percentiles: 90% group.

  3. Analyzing water/wastewater infrastructure interdependencies

    International Nuclear Information System (INIS)

    Gillette, J. L.; Fisher, R. E.; Peerenboom, J. P.; Whitfield, R. G.

    2002-01-01

    This paper describes four general categories of infrastructure interdependencies (physical, cyber, geographic, and logical) as they apply to the water/wastewater infrastructure, and provides an overview of one of the analytic approaches and tools used by Argonne National Laboratory to evaluate interdependencies. Also discussed are the dimensions of infrastructure interdependency that create spatial, temporal, and system representation complexities that make analyzing the water/wastewater infrastructure particularly challenging. An analytical model developed to incorporate the impacts of interdependencies on infrastructure repair times is briefly addressed

  4. Ion sampling and transport in Inductively Coupled Plasma Mass Spectrometry

    Science.gov (United States)

    Farnsworth, Paul B.; Spencer, Ross L.

    2017-08-01

    Quantitative accuracy and high sensitivity in inductively coupled plasma mass spectrometry (ICP-MS) depend on consistent and efficient extraction and transport of analyte ions from an inductively coupled plasma to a mass analyzer, where they are sorted and detected. In this review we examine the fundamental physical processes that control ion sampling and transport in ICP-MS and compare the results of theory and computerized models with experimental efforts to characterize the flow of ions through plasma mass spectrometers' vacuum interfaces. We trace the flow of ions from their generation in the plasma, into the sampling cone, through the supersonic expansion in the first vacuum stage, through the skimmer, and into the ion optics that deliver the ions to the mass analyzer. At each stage we consider idealized behavior and departures from ideal behavior that affect the performance of ICP-MS as an analytical tool.

  5. An Interlaboratory Evaluation of Drift Tube Ion Mobility–Mass Spectrometry Collision Cross Section Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Stow, Sarah M. [Department; Causon, Tim J. [Division; Zheng, Xueyun [Biological; Kurulugama, Ruwan T. [Agilent Technologies, Santa Clara, California 95051, United States; Mairinger, Teresa [Division; May, Jody C. [Department; Rennie, Emma E. [Agilent Technologies, Santa Clara, California 95051, United States; Baker, Erin S. [Biological; Smith, Richard D. [Biological; McLean, John A. [Department; Hann, Stephan [Division; Fjeldsted, John C. [Agilent Technologies, Santa Clara, California 95051, United States

    2017-08-14

    Collision cross section (CCS) measurements resulting from ion mobility-mass spectrometry (IM-MS) experiments provide a promising orthogonal dimension of structural information in MS-based analytical separations. As with any molecular identifier, interlaboratory standardization must precede broad range integration into analytical workflows. In this study, we present a reference drift tube ion mobility mass spectrometer (DTIM-MS) where improvements on the measurement accuracy of experimental parameters influencing IM separations provide standardized drift tube, nitrogen CCS values (DTCCSN2) for over 120 unique ion species with the lowest measurement uncertainty to date. The reproducibility of these DTCCSN2 values are evaluated across three additional laboratories on a commercially available DTIM-MS instrument. The traditional stepped field CCS method performs with a relative standard deviation (RSD) of 0.29% for all ion species across the three additional laboratories. The calibrated single field CCS method, which is compatible with a wide range of chromatographic inlet systems, performs with an average, absolute bias of 0.54% to the standardized stepped field DTCCSN2 values on the reference system. The low RSD and biases observed in this interlaboratory study illustrate the potential of DTIM-MS for providing a molecular identifier for a broad range of discovery based analyses.

  6. Limits on neutrino masses from tritium beta decay

    CERN Document Server

    Bonn, J; Bornschein, L; Flatt, B; Kraus, C V; Otten, E W; Schall, J P; Thuemmler, T; Weinheimer, C

    2002-01-01

    The presently lowest limit for the mass of the electron neutrino is m nu < 2.2 eV (95 % C.L.) derived from measurements at Mainz up to 1999. The data taken in 2000 are not fully analyzed yet but limits of possible distortions as reported by the Troitsk group can be given. The next generation neutrino mass experiment KATRIN is briefly discussed.

  7. Hierarchy plus anarchy in quark masses and mixings

    International Nuclear Information System (INIS)

    Aguilar-Saavedra, J.A.

    2003-01-01

    We introduce a parametrization of the effect of unknown corrections from new physics on quark and lepton mass matrices. This parametrization is used in order to study how the hierarchies of quark masses and mixing angles are modified by random perturbations of the Yukawa matrices. We discuss several examples of flavor relations predicted by different textures, analyzing how these relations are influenced by the random perturbations. We also comment on the unlikely possibility that unknown corrections contribute significantly to the hierarchy of masses and mixings

  8. Highly multiparametric analysis by mass cytometry.

    Science.gov (United States)

    Ornatsky, Olga; Bandura, Dmitry; Baranov, Vladimir; Nitz, Mark; Winnik, Mitchell A; Tanner, Scott

    2010-09-30

    This review paper describes a new technology, mass cytometry, that addresses applications typically run by flow cytometer analyzers, but extends the capability to highly multiparametric analysis. The detection technology is based on atomic mass spectrometry. It offers quantitation, specificity and dynamic range of mass spectrometry in a format that is familiar to flow cytometry practitioners. The mass cytometer does not require compensation, allowing the application of statistical techniques; this has been impossible given the constraints of fluorescence noise with traditional cytometry instruments. Instead of "colors" the mass cytometer "reads" the stable isotope tags attached to antibodies using metal-chelating labeling reagents. Because there are many available stable isotopes, and the mass spectrometer provides exquisite resolution between detection channels, many parameters can be measured as easily as one. For example, in a single tube the technique allows for the ready detection and characterization of the major cell subsets in blood or bone marrow. Here we describe mass cytometric immunophenotyping of human leukemia cell lines and leukemia patient samples, differential cell analysis of normal peripheral and umbilical cord blood; intracellular protein identification and metal-encoded bead arrays. Copyright © 2010 Elsevier B.V. All rights reserved.

  9. Computed tomographic evaluation of pulmonary mass lesion in chest radiography

    International Nuclear Information System (INIS)

    Choe, Kyu Ok

    1984-01-01

    Until recently, solitary coin lesion of pulmonary disease has been a conspicuous problem in radiologic diagnosis. It is now well informed that CT has offered high resolution with its objective CT numbers to provide additional information in terms of anatomic and pathologic changes. Here by the aid of CT, the authors has retrospectively patients with various shape of round masses thus illustrating the advantage of it over conventional X-ray in diagnosis. 1. Total 53 patients, including 34 males and 19 females, aging between 19 to 76 years old with nodule or mass of any size ranging 1 to 13 cm in diameter were observed. 2. On plain chest X-ray they were identified where 50 patients has single round nodular or mass, only one had two masses which were ecchinococcal cysts, and the rest two had invisible lesions, only detected by CT. 3. With philips tomoscan 310, CT scan was taken 12 mm thicken slice during quiet respiration. Using the ROI cursor the average CT number of the central area was calculated 1.0 cm in side the outer border of the mass. 4. As a consequence of their pathologic features, they were itemized to 4 group as 36 solid, 9 cystic, 4 consolidative and 4 cavitary lesions. 5. Correct diagnosis of 3 cystic lesions, 4 diffuse calcification, 1 A-V malformation were available by CT densitometry. 6. By the aid of better resolution and additional cross-sectional orientation of CT, 3 extrapulmonary lesions, 3 segmental consolidations, 2 bronchocele, and 2 solitary metastasis, were helpful in diagnosis. 7. Also helpful in determining the extent of intrathoracic extent of bronchogenic carcinoma for the same reason but given clues were not more than the ordinary. 8. However, the limitation of the CT densitometry led to miss diagnosis of 3 examples of cystic vs.solid lesions, and CT density of noncalcified granuloma together with bronchogenic carcinoma, did not have a clear cut separation in between.

  10. Evaluation of common mental disorders in women with polycystic ovary syndrome and its relationship with body mass index.

    Science.gov (United States)

    Rodrigues, Cristine Eliane Gomes; Ferreira, Luana de Lima; Jansen, Karen; Lopez, Mariane Ricardo Acosta; Drews Júnior, Cláudio Raul; Souza, Luciano Dias de Mattos

    2012-10-01

    To evaluate the prevalence of common mental disorders in women diagnosed with polycystic ovary syndrome as compared with paired controls without this syndrome. Cross-sectional study with a Control Group examining women between the ages of 18 and 30 who did not use antidepressants and who sought the Gynecology Service of the researched sites. For every woman diagnosed with the polycystic ovary syndrome, another with the same age, educational status and presence or absence of sexual partners was sought without this diagnosis. In total, 166 patients agreed to participate, consisting of 95 diagnosed with polycystic ovary syndrome and 71 in the Control Group. The diagnosis of polycystic ovary syndrome was made by the presence of two from three criteria: oligomenorrhea or amenorrhea, clinical or biochemical hyperandrogenism and polycystic ovaries on transvaginal ultrasound, following exclusion of patients with Cushing's syndrome, congenital adrenal hyperplasia, and androgen-secreting tumors. Weight and height were measured to calculate the body mass index. The Self-Reporting Questionnaire, which evaluated 20 items, was used as an indicator of common mental disorders. A χ² analysis stratified by the category of body mass index was used to compare the prevalence of common mental disorders, between the groups of women with and without the polycystic ovary syndrome. There were no significant differences in age, education, presence of sexual partners, ethnicity, socioeconomic status, use of psychiatric medication, and search for consultation in mental health between the studied groups. The prevalence of obese women with indications of common mental disorders was significantly higher in women with polycystic ovary syndrome than in the Control Group. In the group with healthy body mass index, the incidence of common mental disorders was statistically significant different between women with polycystic ovary syndrome and normal controls (p=0.008). Women with diagnosis of this

  11. Application of Six Sigma Model to Evaluate the Analytical Quality of Four HbA1c Analyzers.

    Science.gov (United States)

    Maesa, Jos Eacute M; Fern Aacute Ndez-Riejos, Patricia; S Aacute Nchez-Mora, Catalina; Toro-Crespo, Mar Iacute A De; Gonz Aacute Lez-Rodriguez, Concepci Oacute N

    2017-01-01

    The Six Sigma Model is a global quality management system applicable to the determination of glycated hemoglobin (HbA1c). In addition, this model can ensure the three characteristics influencing the patient risk: the correct performance of the analytical method with low inaccuracy and bias, the quality control strategy used by the laboratory, and the necessary quality of the analyte. The aim of this study is to use the Six Sigma Model for evaluating quality criteria in the determination of glycated hemoglobin HbA1c and its application to assess four different HbA1c analyzers. Four HbA1c analyzers were evaluated: HA-8180V®, D-100®, G8®, and Variant II Turbo®. For 20 consecutive days, two levels of quality control (high and low) provided by the manufacturers were measured in each of the instruments. Imprecision (CV), bias, and Sigma values (σ) were calculated with the data obtained and a method decision chart was developed considering a range of quality requirements (allowable total error, TEa). For a TEa = 3%, HA-8180V = 1.54 σ, D-100 = 1.63 σ, G8 = 2.20 σ, and Variant II Turbo = -0.08 σ. For a TEa = 4%, HA-8180V = 2.34 σ, D-100 = 2.32 σ, G8 = 3.74 σ, and Variant II Turbo = 0.16 σ. For a TEa = 10%, HA8180V = 7.12 σ, D-100 = 6.46 σ, G8 = 13.0 σ, and Variant II Turbo = 1.56 σ. Applying the Stockholm consensus and its subsequent Milan review to the results: the maximum level in quality requirements for HbA1c is an allowable total error (TEa) = 3%, G8 is located in region 2 σ (2.20), which is a poor result, and HA-8180V and D-100 are both in region 1 σ (1.54 and 1.63, respectively), which is an unacceptable analytical performance.

  12. On the Mass Balance of Asphaltene Precipitation

    DEFF Research Database (Denmark)

    Andersen, Simon Ivar; Lira-Galeana, C.; Stenby, Erling Halfdan

    2001-01-01

    In the evaluation of experimental data as well as in calculation of phase equilibria the necessity of the application of mass balances is obvious. In the case of asphaltenes the colloidal nature of these compounds may highly affect the mass balance. In the present paper several experiments are pe......, and that the material in the second precipitation step was often of higher apparent molecular weight anti had an increased overall absorbance coefficient.......In the evaluation of experimental data as well as in calculation of phase equilibria the necessity of the application of mass balances is obvious. In the case of asphaltenes the colloidal nature of these compounds may highly affect the mass balance. In the present paper several experiments...... indicates that in temperature experiments as well as in solvent series experiments the precipitation of heavy asphaltenes affects the following precipitation of lighter asphaltenes. In both cases the mass balance using standard separation techniques cannot be closed, as less material is precipitated...

  13. The combined use of US and MR imaging for the diagnosis of masses in the parotid region

    International Nuclear Information System (INIS)

    Goto, T.K.; Yoshiura, K.; Nakayama, E.; Yuasa, K.; Tabata, O.; Nakano, T.; Kawazu, T.; Tanaka, T.; Miwa, K.; Shimizu, M.; Chikui, T.; Okamura, K.; Kanda, S.

    2000-01-01

    To evaluate the usefulness of the combination of the two non-invasive modalities US and MR imaging to diagnose masses in the parotid region. The US and MR findings of 21 patients with parotid masses were analyzed retrospectively by two radiologists without any clinical or histopathological information. The specific points evaluated were location, shape, margin, internal architecture, and intensity level on both US and MR, posterior echo enhancement on US, and capsule-like lining of the tumor on MR. The findings concerning the shape and margin on US and MR were in fairly good agreement. Concerning the findings of the internal architecture, US could reveal the minute structures of the tumor while MR demonstrated differences in the signal intensities of histological tissue types of the various tumors. The posterior echo enhancement on US and the capsule-like lining on MR of the tumors were also useful for the diagnosis. Our results suggest that the combination of US and MR is useful for examining soft tissue masses in the parotid region to make a more accurate diagnosis, and not just differentiate malignant lesions from those which are benign

  14. Comparison of a burning mass ceramics coating in laboratory furnace and instrustrial furnace; Comparacao de queimas de uma massa ceramica de revestimento em forno de laboratorio e forno industrial

    Energy Technology Data Exchange (ETDEWEB)

    Soares, R.A.L., E-mail: robertoarruda@ifpi.edu.br [Instituto Federal de Educacao, Ciencia e Tecnologia do Piaui (IFPI), Terersina, PI (Brazil); Castro, J.R. de S. [Universidade Federal do Piaui (UFPI), Teresina, PI (Brazil)

    2012-07-01

    This work intends to analyze the differences obtained in the technological properties of a ceramic coating after firing in two distinct environments, laboratory furnace and industrial furnace. For this, was characterized a ceramic mass used in the production of porous coating. The analyzes were performed chemical, mineralogical and thermal mass in that. The specimens were obtained by compacting and burned in the maximum temperature of 1140 deg C in two furnaces, laboratory and industrial. The technological tests were performed linear shrinkage, water absorption, bulk density and mechanical strength. The microstructure was evaluated by ray-X diffraction and scanning electron microscopy. The results showed that both furnaces provided significant differences in analyzed specimens, such as increased strength and low water absorption in the fired samples in a laboratory furnace, for example. (author)

  15. Evaluation of supercritical fluid chromatography coupled to tandem mass spectrometry for pesticide residues in food.

    Science.gov (United States)

    Cutillas, Víctor; Galera, María Martínez; Rajski, Łukasz; Fernández-Alba, Amadeo R

    2018-04-13

    Supercritical fluid chromatography coupled to triple quadrupole mass spectrometry has been evaluated for pesticide residues in food. In order to check its advantages and limitations it was developed a method to identify and quantify 164 pesticides in three different matrices (tomato, orange and leek). A carbon dioxide gradient with methanol (containing 1 mM ammonium formate) was used allowing a flow rate of 1.5 mL/min that made the total run time of 12 min without any problem of overpressure. Addition of a post column flow 150 μL/min of Methanol with ammonium formate/formic acid was necessary to improve the ionization. The matrix effect study revealed that the percentages of pesticides with irrelevant matrix effect (suppression lower than 20%) was 99% in tomato, 87% in orange and 62% in leek, whereas significant suppression (higher than 50%) was not found in tomato and only 1% of the compounds in orange and 3% in leek.These results compare favorably with that typically obtained in LC-MS/MS. The absence of water in the mobile phase, also provided some important advantages regarding LC-MS/MS as (i) higher retention of polar compounds in the column, which elute with high sensitivity and good peak shape and (ii) a general increase of the sensitivity of the analysis, consequence of the high ionization and ion extraction efficiency. Pesticides evaluated were identified following the SANTE/11813/2017. At the spiking concentration of 5 μg/kg, 98% of the pesticides were identified in tomato, 98% in orange and 94% in leek, whereas for the concentration of 10 μg/kg all the compounds were identified in tomato and only spiromesifen was not identified in orange and leek. At the concentration of 20 μg/kg, spiromesifen was also identified in these two matrices. The linearity and reproducibility of the method were evaluated with results which guarantee high quality in the analytical measurements. Even though only 2 μL of final extract were injected, the

  16. Comparative Study for Evaluation of Mass Flow Rate for Simple Solar Still and Active with Heat Pump

    OpenAIRE

    Hidouri Khaoula; Benhmidene Ali; Chaouachi Bechir; Ravishankar Sathyamurthy

    2017-01-01

    In isolated and arid areas, especially in the almost Maghreb regions, the abundant solar radiation intensity along the year and the available brackish water resources are the two favorable conditions for using solar desalination technology to produce fresh water. The present study is based on the use of three groups of correlation, for evaluating mass transfer. Theoretical results are compared with those obtained experimentally for a Simple Solar Distiller (SSD) and a Simple Solar Distiller H...

  17. Recent applications of gas chromatography with high-resolution mass spectrometry.

    Science.gov (United States)

    Špánik, Ivan; Machyňáková, Andrea

    2018-01-01

    Gas chromatography coupled to high-resolution mass spectrometry is a powerful analytical method that combines excellent separation power of gas chromatography with improved identification based on an accurate mass measurement. These features designate gas chromatography with high-resolution mass spectrometry as the first choice for identification and structure elucidation of unknown volatile and semi-volatile organic compounds. Gas chromatography with high-resolution mass spectrometry quantitative analyses was previously focused on the determination of dioxins and related compounds using magnetic sector type analyzers, a standing requirement of many international standards. The introduction of a quadrupole high-resolution time-of-flight mass analyzer broadened interest in this method and novel applications were developed, especially for multi-target screening purposes. This review is focused on the development and the most interesting applications of gas chromatography coupled to high-resolution mass spectrometry towards analysis of environmental matrices, biological fluids, and food safety since 2010. The main attention is paid to various approaches and applications of gas chromatography coupled to high-resolution mass spectrometry for non-target screening to identify contaminants and to characterize the chemical composition of environmental, food, and biological samples. The most interesting quantitative applications, where a significant contribution of gas chromatography with high-resolution mass spectrometry over the currently used methods is expected, will be discussed as well. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. The project of the mass separator of atomic nuclei produced in heavy ion induced reactions

    Science.gov (United States)

    Oganessian, Yu. Ts.; Shchepunov, V. A.; Dmitriev, S. N.; Itkis, M. G.; Gulbekyan, G. G.; Khabarov, M. V.; Bekhterev, V. V.; Bogomolov, S. L.; Efremov, A. A.; Pashenko, S. V.; Stepantsov, S. V.; Yeremin, A. V.; Yavor, M. I.; Kalimov, A. G.

    2003-05-01

    A new separator and mass analyzer, named MASHA (mass analyzer of super heavy atoms), has been designed at the Flerov Laboratory JINR Dubna to separate and measure masses of nuclei and molecules with precision better than 10 -3. The set up can work in the wide mass range from A≈20 to A≈500, its mass acceptance is as large as ±2.8%. In particular, it allows unambiguous mass identification of super heavy nuclei with a resolution better than 1 amu at the level of 300 amu. Synthesized in nuclear reactions nuclides are emitted from an ECR ion source at energy E=40 kV and charge state Q=+1. Then they pass the following steps of separation and analysis: the first section of rough separation, the second section of separation and mass analysis and the final section of separation with a 90° electrostatic deflector. In the focal plane of the device, a focal plane detector determines positions (masses) of studied nuclei. Ion optics of the analyzer, optimized up to the second order, is considered. Description of its elements and subsystems is given.

  19. The project of the mass separator of atomic nuclei produced in heavy ion induced reactions

    International Nuclear Information System (INIS)

    Oganessian, Yu.Ts.; Shchepunov, V.A.; Dmitriev, S.N.; Itkis, M.G.; Gulbekyan, G.G.; Khabarov, M.V.; Bekhterev, V.V.; Bogomolov, S.L.; Efremov, A.A.; Pashenko, S.V.; Stepantsov, S.V.; Yeremin, A.V.; Yavor, M.I.; Kalimov, A.G.

    2003-01-01

    A new separator and mass analyzer, named MASHA (mass analyzer of super heavy atoms), has been designed at the Flerov Laboratory JINR Dubna to separate and measure masses of nuclei and molecules with precision better than 10 -3 . The set up can work in the wide mass range from A∼20 to A∼500, its mass acceptance is as large as ±2.8%. In particular, it allows unambiguous mass identification of super heavy nuclei with a resolution better than 1 amu at the level of 300 amu. Synthesized in nuclear reactions nuclides are emitted from an ECR ion source at energy E=40 kV and charge state Q=+1. Then they pass the following steps of separation and analysis: the first section of rough separation, the second section of separation and mass analysis and the final section of separation with a 90 deg. electrostatic deflector. In the focal plane of the device, a focal plane detector determines positions (masses) of studied nuclei. Ion optics of the analyzer, optimized up to the second order, is considered. Description of its elements and subsystems is given

  20. The project of the mass separator of atomic nuclei produced in heavy ion induced reactions

    Energy Technology Data Exchange (ETDEWEB)

    Oganessian, Yu.Ts.; Shchepunov, V.A. E-mail: shchepun@sunhe.jinr.rushchepun@cv.jinr.ru; Dmitriev, S.N.; Itkis, M.G.; Gulbekyan, G.G.; Khabarov, M.V.; Bekhterev, V.V.; Bogomolov, S.L.; Efremov, A.A.; Pashenko, S.V.; Stepantsov, S.V.; Yeremin, A.V.; Yavor, M.I.; Kalimov, A.G

    2003-05-01

    A new separator and mass analyzer, named MASHA (mass analyzer of super heavy atoms), has been designed at the Flerov Laboratory JINR Dubna to separate and measure masses of nuclei and molecules with precision better than 10{sup -3}. The set up can work in the wide mass range from A{approx}20 to A{approx}500, its mass acceptance is as large as {+-}2.8%. In particular, it allows unambiguous mass identification of super heavy nuclei with a resolution better than 1 amu at the level of 300 amu. Synthesized in nuclear reactions nuclides are emitted from an ECR ion source at energy E=40 kV and charge state Q=+1. Then they pass the following steps of separation and analysis: the first section of rough separation, the second section of separation and mass analysis and the final section of separation with a 90 deg. electrostatic deflector. In the focal plane of the device, a focal plane detector determines positions (masses) of studied nuclei. Ion optics of the analyzer, optimized up to the second order, is considered. Description of its elements and subsystems is given.

  1. Peak bone mineral density, lean body mass and fractures

    NARCIS (Netherlands)

    Boot, Annemieke M.; de Ridder, Maria A. J.; van der Sluis, Inge M.; van Slobbe, Ingrid; Krenning, Eric P.; Keizer-Schrama, Sabine M. P. F. de Muinck

    Background: During childhood and adolescence, bone mass and lean body mass (LBM) increase till a plateau is reached. In this longitudinal and cross-sectional study, the age of reaching the plateau was evaluated for lumbar spine and total body bone mass measurements and lean body mass. The

  2. Gas Chromatography-Mass Spectrometric Analysis and Insecticidal ...

    African Journals Online (AJOL)

    Tropical Journal of Pharmaceutical Research ... apelta aerial parts was analyzed by gas chromatography/mass spectrometric (GC/MS) to determine its composition. ... into a natural fumigant/insecticide for the control of stored product insects.

  3. RESEARCH OF THE METABOLIC AGE AND BODY MASS INDEX FOR FEMALE STUDENTS

    Directory of Open Access Journals (Sweden)

    Galina Petrova Dyakova

    2011-09-01

    Full Text Available Metabolic age - this feature takes into account, the basic metabolism and all the basic physical parameters and the determining of age, which corresponds to this type of metabolism. The aim of the research is to establish a metabolic age and the index of the body mass (Body Mass Index for students. Anthropometric measurement was applied. The analyzer was used for the composition of body weight (body composition analyzer, BC-420MA “Tanita” for determining the metabolic age and body mass index. The conducted monitoring of the metabolic age reveals opportunities to improve students' motivation for healthy lifestyle.

  4. Applications of accelerator mass spectrometry to nuclear physics and astrophysics

    International Nuclear Information System (INIS)

    Guo Zhiyu; Zhang Chuan

    2002-01-01

    As an ultra high sensitive analyzing method, accelerator mass spectrometry is playing an important role in the studies of nuclear physics and astrophysics. The accelerator mass spectrometry (AMS) applications in searching for violation of Pauli exclusion principle and study on supernovae are discussed as examples

  5. Atmospheric pressure plasma analysis by modulated molecular beam mass spectrometry

    NARCIS (Netherlands)

    Aranda Gonzalvo, Y.; Whitmore, T.D.; Rees, J.A.; Seymour, D.L.; Stoffels - Adamowicz, E.

    2006-01-01

    Fractional no. d. measurements for a radiofrequency plasma needle operating at atm. pressure were obtained using a mol. beam mass spectrometer (MBMS) system designed for diagnostics of atm. plasmas. The MBMS system comprises three differentially pumped stages and a mass/energy analyzer and includes

  6. [Clinical analysis of vocal fold firbrous mass].

    Science.gov (United States)

    Chen, Hao; Sun, Jing Wu; Wan, Guang Lun; Hu, Yan Ming

    2018-03-01

    To explore the character of laryngoscopy finding, voice, and therapy of vocal fold fibrous mass. Clinical data, morphology, voice character, surgery and pathology of 15 cases with vocal fold fibrous mass were analyzed. The morbidity of vocal fold fibrous mass might be related to overuse of voice and laryngopharyngeal reflex. Laryngoscopy revealed shuttle line appearance, smoothness and decreased mucosal wave of vocal fold. These patients were invalid for voice training and might be improved by surgery, but recovery is slow. The morbidity of vocal fold fibrous mass might be related to overuse of voice and laryngopharyngeal reflex. Conservative treatment is ineffective for this disease, and surgery might improve. Copyright© by the Editorial Department of Journal of Clinical Otorhinolaryngology Head and Neck Surgery.

  7. Radio-frequency ion deflector for mass separation

    Energy Technology Data Exchange (ETDEWEB)

    Schlösser, Magnus, E-mail: magnus.schloesser@googlemail.com; Rudnev, Vitaly; Ureña, Ángel González, E-mail: laseres@pluri.ucm.es [Unidad de Láseres y Haces Moleculares, Instituto Plurisdisciplinar, Universidad Complutense de Madrid, Madrid 28040 (Spain)

    2015-10-15

    Electrostatic cylindrical deflectors act as energy analyzer for ion beams. In this article, we present that by imposing of a radio-frequency modulation on the deflecting electric field, the ion transmission becomes mass dependent. By the choice of the appropriate frequency, amplitude, and phase, the deflector can be used as mass filter. The basic concept of the new instrument as well as simple mathematic relations are described. These calculations and further numerical simulations show that a mass sensitivity is achievable. Furthermore, we demonstrate the proof-of-principle in experimental measurements, compare the results to those of from a 1 m linear time-of-flight spectrometer, and comment on the mass resolution of the method. Finally, some potential applications are indicated.

  8. Modelling mass diffusion for a multi-layer sphere immersed in a semi-infinite medium: application to drug delivery.

    Science.gov (United States)

    Carr, Elliot J; Pontrelli, Giuseppe

    2018-04-12

    We present a general mechanistic model of mass diffusion for a composite sphere placed in a large ambient medium. The multi-layer problem is described by a system of diffusion equations coupled via interlayer boundary conditions such as those imposing a finite mass resistance at the external surface of the sphere. While the work is applicable to the generic problem of heat or mass transfer in a multi-layer sphere, the analysis and results are presented in the context of drug kinetics for desorbing and absorbing spherical microcapsules. We derive an analytical solution for the concentration in the sphere and in the surrounding medium that avoids any artificial truncation at a finite distance. The closed-form solution in each concentric layer is expressed in terms of a suitably-defined inverse Laplace transform that can be evaluated numerically. Concentration profiles and drug mass curves in the spherical layers and in the external environment are presented and the dependency of the solution on the mass transfer coefficient at the surface of the sphere analyzed. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. Regioisomers of octanoic acid-containing structured triacylglycerols analyzed by tandem mass spectrometry using ammonia negative ion chemical ionization

    DEFF Research Database (Denmark)

    Kurvinen, J.P.; Mu, Huiling; Kallio, H.

    2001-01-01

    Tandem mass spectrometry based on ammonia negative ion chemical ionization and sample introduction via direct exposure probe was applied to analysis of regioisomeric structures of octanoic acid containing structured triacylglycerols (TAG) of type MML, MLM, MLL, and LML (M, medium-chain fatty acid...

  10. MR findings of primary scalp mass

    International Nuclear Information System (INIS)

    Kim, Jee Eun; Hwang, Hee Young; Park, Sung Hye; Kim, Young Chae; Lee, Young Suk

    1996-01-01

    To evaluate the diagnostic value of MRI, we compared MR images of primary scalp mass with pathological findings. Eight cases in seven patients who had presented primary scalp mass during the previous three years were evaluated by MRI and confirmed with surgical excision and pathologic evaluation. 0.38T(Resonex 4000, USA) MRI was used and all MR images were analysed retrospectively. Eight pathologically confirmed cases consisted of three cases of epidermal cysts, one of steatocystoma simplex, three of neurofibromatosis and one of lymphangioma. All epidermal cysts were located in the occipital area and showed a higher signal intensity than CSF in T1WI, and proton density and variable signal intensity in T2WI. The Steatocystoma showed a signal iniensity similar to fat in T1WI and proton density and a lower signal intensity than fat in T2WI. Neurofibromatosis accounted for three cases in two neurofibromatosis patients;one was located in the right parieto-occipital area and accompanied by hematoma and skull defect; two cases were located in the occipital and posterior cervical area of the same patient. The masses showed a higher signal intensity than muscle in T1WI and hyper or isointensity in T2WI with well enhancement. The lymphangioma showed a signal intensity similar to CSF in all pulse sequences and contained a fat component. MRI is a useful modality for evaluating primary scalp mass

  11. Evaluation of left ventricular mass in vitro and in vivo with MR imaging

    International Nuclear Information System (INIS)

    Mogelvang, J.; Thomsen, C.; Mehisen, J.; Henriksen, O.; Horn, T.

    1986-01-01

    The left ventricular (LV) mass was determined by MR multisection imaging in ten unopened postmortem human hearts and compared with the true weight of the isolated LV. In addition, the LV mass in 14 patients was determined by MR imaging. LV myocardial volume determined from acquisitions at end diastole were compared with the volume determined from acquisitions at end systole. The LV masses as determined on MR imaging showed excellent correlation with reference values (r = .99, P < .001). There was fine correlation between myocardial volume (mass) estimated in vivo in diastole and systole (r = .95, P < .0001). These results suggest that MR imaging is accurate for the determination of LV mass in vivo

  12. Evaluating the contribution of differences in lean mass compartments for resting energy expenditure in African American and Caucasian American children.

    Science.gov (United States)

    Broadney, M M; Shareef, F; Marwitz, S E; Brady, S M; Yanovski, S Z; DeLany, J P; Yanovski, J A

    2018-04-26

    Resting energy expenditure (REE), adjusted for total lean mass (LM), is lower in African American (AA) than Caucasian American (CA) children. Some adult studies suggest that AA-CA differences in lean mass compartments explain this REE difference. Similar data are limited in children. To evaluate differences in compartment-specific lean mass between AA and CA children and examine the individual contributions of high-metabolic rate-at-rest trunk lean mass (TrLM) and low-metabolic-rate-at-rest appendicular lean mass (AppLM) for AA-CA differences in REE. We studied a convenience sample of 594 AA (n = 281) and CA (n = 313) children. REE was measured by using indirect calorimetry; dual-energy X-ray absorptiometry was used to assess body composition. ANCOVAs were performed to examine AA-CA differences in TrLM, AppLM and REE. After accounting for age, sex, height, pubertal development, bone mass and adiposity, REE was evaluated adjusting for total LM (model A) and separately adjusting for TrLM and AppLM (model B). African American children had greater adjusted AppLM (17.8 ± 0.2 [SE] vs. 16.0 ± 0.2 kg, p < 0.001) and lower TrLM (17.2 ± 0.2 vs. 17.7 ± 0.2 kg, p = 0.022) than CA children. REE adjusted for total LM was 77 ± 16 kcal/d lower in AA than CA (p < 0.001). However, after accounting separately for AppLM and TrLM, the discrepancy in REE between the groups declined to 28 ± 19 kcal/d (p = 0.14). In the adjusted model, both TrLM (p < 0.001) and AppLM (p < 0.027) were independently associated with REE. In children, AA-CA differences in REE appear mostly attributable to differences in body composition. Lower REE in AA children is likely due to lower TrLM and greater AppLM. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.

  13. [Uncertainty evaluation of the determination of toxic equivalent quantity of polychlorinated dibenzo-p-dioxins and dibenzofurans in soil by isotope dilution high resolution gas chromatography and high resolution mass spectrometry].

    Science.gov (United States)

    Du, Bing; Liu Aimin; Huang, Yeru

    2014-09-01

    Polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in soil samples were analyzed by isotope dilution method with high resolution gas chromatography and high resolution mass spectrometry (ID-HRGC/HRMS), and the toxic equivalent quantity (TEQ) were calculated. The impacts of major source of measurement uncertainty are discussed, and the combined relative standard uncertainties were calculated for each 2, 3, 7, 8 substituted con- gener. Furthermore, the concentration, combined uncertainty and expanded uncertainty for TEQ of PCDD/Fs in a soil sample in I-TEF, WHO-1998-TEF and WHO-2005-TEF schemes are provided as an example. I-TEF, WHO-1998-TEF and WHO-2005-TEF are the evaluation schemes of toxic equivalent factor (TEF), and are all currently used to describe 2,3,7,8 sub- stituted relative potencies.

  14. Evaluation of the hemoglobin A1c-analyzer TOSOH HLC-723 G7.

    Science.gov (United States)

    Gremmels, Heinz-Detlef; Richter, Anja; Watzke, Ivonne

    2003-01-01

    The TOSOH HLC-723 G7 is a compact analyzer designed for the measurement of HbA1c under routine laboratory conditions. The analyzer has an automatic blood tube supply and positive sample identification. Samples are transported automatically via racks in a continuous-load mode, cap piercing is optional. Tests devoted to the assessment of reproducibility and accuracy of analytical results indicated that over a test period of 17 days, the intra-assay variation (CV) was 1.79%, and the inter-assay variation 2.60%, respectively. A comparison with the predecessor model G5 showed a very good correlation (r = 0.997, y = 1.0041x - 0.00172; n = 149). The presence of high triglyceride, bilirubin or urea concentrations in patient samples did not influence the analytical precision. The labile HbA1c fraction (L-A1c) is clearly separated during chromatography and thus does not compromise HbA1c analysis. With a protocol of 1.2 minutes, the TOSOH G7 is a very fast analyzer, designed for laboratories with a high throughput of samples.

  15. Deep learning for tumor classification in imaging mass spectrometry.

    Science.gov (United States)

    Behrmann, Jens; Etmann, Christian; Boskamp, Tobias; Casadonte, Rita; Kriegsmann, Jörg; Maaß, Peter

    2018-04-01

    Tumor classification using imaging mass spectrometry (IMS) data has a high potential for future applications in pathology. Due to the complexity and size of the data, automated feature extraction and classification steps are required to fully process the data. Since mass spectra exhibit certain structural similarities to image data, deep learning may offer a promising strategy for classification of IMS data as it has been successfully applied to image classification. Methodologically, we propose an adapted architecture based on deep convolutional networks to handle the characteristics of mass spectrometry data, as well as a strategy to interpret the learned model in the spectral domain based on a sensitivity analysis. The proposed methods are evaluated on two algorithmically challenging tumor classification tasks and compared to a baseline approach. Competitiveness of the proposed methods is shown on both tasks by studying the performance via cross-validation. Moreover, the learned models are analyzed by the proposed sensitivity analysis revealing biologically plausible effects as well as confounding factors of the considered tasks. Thus, this study may serve as a starting point for further development of deep learning approaches in IMS classification tasks. https://gitlab.informatik.uni-bremen.de/digipath/Deep_Learning_for_Tumor_Classification_in_IMS. jbehrmann@uni-bremen.de or christianetmann@uni-bremen.de. Supplementary data are available at Bioinformatics online.

  16. Mass measurement of cooled neutron-deficient bismuth projectile fragments with time-resolved Schottky mass spectrometry at the FRS-ESR facility

    Energy Technology Data Exchange (ETDEWEB)

    Litvinov, Yu.A.; Geissel, H. [Giessen Univ. (Germany); Radon, T. [Gesellschaft fuer Schwerionenforschung mbH, Darmstadt (DE)] [and others

    2005-06-01

    Masses of 582 neutron-deficient nuclides (30{<=}Z{<=}85) were measured with time-resolved Schottky mass spectrometry at the FRS-ESR facility at GSI, 117 were used for calibration. The masses of 71 nuclides were obtained for the first time. A typical mass accuracy of 30 {mu}u was achieved. These data have entered the latest atomic mass evaluation. The mass determination of about 140 additional nuclides was possible via known energies (Q-values) of {alpha}-, {beta}-, or proton decays. The obtained results are compared with the results of other measurements. (orig.)

  17. THE EXPERIENCE OF COMPARISON OF STATIC SECURITY CODE ANALYZERS

    Directory of Open Access Journals (Sweden)

    Alexey Markov

    2015-09-01

    Full Text Available This work presents a methodological approach to comparison of static security code analyzers. It substantiates the comparison of the static analyzers as to efficiency and functionality indicators, which are stipulated in the international regulatory documents. The test data for assessment of static analyzers efficiency is represented by synthetic sets of open-source software, which contain vulnerabilities. We substantiated certain criteria for quality assessment of the static security code analyzers subject to standards NIST SP 500-268 and SATEC. We carried out experiments that allowed us to assess a number of the Russian proprietary software tools and open-source tools. We came to the conclusion that it is of paramount importance to develop Russian regulatory framework for testing software security (firstly, for controlling undocumented features and evaluating the quality of static security code analyzers.

  18. E parallel B end-loss-ion analyzer for the Tandem Mirror Experiment-Upgrade (TMX-U). Revision 1

    International Nuclear Information System (INIS)

    Wood, B.E.; Foote, J.H.; Coutts, G.W.; Pedrotti, L.R.; Schlander, L.F.; Brown, M.D.

    1985-01-01

    We have installed a new diagnostic instrument to investigate ions emanating along magnetic-field lines of the TMX-U tandem-mirror experiment. This analyzer contains parallel electric and magnetic fields, which yield ion mass and energy spatial separation. A dual array of 128 copper collector plates detects particles in the ion flux that is first collimated and then focused through the 180-degree bending magnetic field. An electric field applied transverse to the bending particle path then separates the ion masses in the direction perpendicular to the magnetic-pole faces while the magnetic field spreads out the different energies of each mass in a plane parallel to the magnetic-pole tips. The CAMAC-based data recorders are fiber-optically coupled to the system controller for data acquisition, analysis, and display. A commercial CAMAC data recorder was modified for current input. We expect to measure higher particle energies than the present gridded end-loss analyzers as well as to more accurately determine the energy spectra

  19. Transient analyzer

    International Nuclear Information System (INIS)

    Muir, M.D.

    1975-01-01

    The design and design philosophy of a high performance, extremely versatile transient analyzer is described. This sub-system was designed to be controlled through the data acquisition computer system which allows hands off operation. Thus it may be placed on the experiment side of the high voltage safety break between the experimental device and the control room. This analyzer provides control features which are extremely useful for data acquisition from PPPL diagnostics. These include dynamic sample rate changing, which may be intermixed with multiple post trigger operations with variable length blocks using normal, peak to peak or integrate modes. Included in the discussion are general remarks on the advantages of adding intelligence to transient analyzers, a detailed description of the characteristics of the PPPL transient analyzer, a description of the hardware, firmware, control language and operation of the PPPL transient analyzer, and general remarks on future trends in this type of instrumentation both at PPPL and in general

  20. Effects of high-intensity exercise and protein supplement on muscle mass in ADL dependent older people with and without malnutrition: a randomized controlled trial.

    Science.gov (United States)

    Carlsson, M; Littbrand, H; Gustafson, Y; Lundin-Olsson, L; Lindelöf, N; Rosendahl, E; Håglin, L

    2011-08-01

    Loss of muscle mass is common among old people living in institutions but trials that evaluate interventions aimed at increasing the muscle mass are lacking. Objective, participants and intervention: This randomized controlled trial was performed to evaluate the effect of a high-intensity functional exercise program and a timed protein-enriched drink on muscle mass in 177 people aged 65 to 99 with severe physical or cognitive impairments, and living in residential care facilities. Three-month high-intensity exercise was compared with a control activity and a protein-enriched drink was compared with a placebo drink. A bioelectrical impedance spectrometer (BIS) was used in the evaluation. The amount of muscle mass and body weight (BW) were followed-up at three and six months and analyzed in a 2 x 2 factorial ANCOVA, using the intention to treat principle, and controlling for baseline values. At 3-month follow-up there were no differences in muscle mass and BW between the exercise and the control group or between the protein and the placebo group. No interaction effects were seen between the exercise and nutritional intervention. Long-term negative effects on muscle mass and BW was seen in the exercise group at the 6-month follow-up. A three month high-intensity functional exercise program did not increase the amount of muscle mass and an intake of a protein-enriched drink immediately after the exercise did not induce any additional effect on muscle mass. There were negative long-term effects on muscle mass and BW, indicating that it is probably necessary to compensate for an increased energy demand when offering a high-intensity exercise program.