  1. Miniature mass analyzer

    CERN Document Server

    Cuna, C; Lupsa, N; Cuna, S; Tuzson, B

    2003-01-01

    The paper presents the concept of different mass analyzers that were specifically designed as small dimension instruments able to detect with great sensitivity and accuracy the main environmental pollutants. The mass spectrometers are very suited instrument for chemical and isotopic analysis, needed in environmental surveillance. Usually, this is done by sampling the soil, air or water followed by laboratory analysis. To avoid drawbacks caused by sample alteration during the sampling process and transport, the 'in situ' analysis is preferred. Theoretically, any type of mass analyzer can be miniaturized, but some are more appropriate than others. Quadrupole mass filter and trap, magnetic sector, time-of-flight and ion cyclotron mass analyzers can be successfully shrunk, for each of them some performances being sacrificed but we must know which parameters are necessary to be kept unchanged. To satisfy the miniaturization criteria of the analyzer, it is necessary to use asymmetrical geometries, with ion beam obl...

  2. Mass spectrometer calibration of Cosmic Dust Analyzer

    Science.gov (United States)

    Ahrens, Thomas J.; Gupta, Satish C.; Jyoti, G.; Beauchamp, J. L.

    2003-02-01

    The time-of-flight (TOF) mass spectrometer (MS) of the Cosmic Dust Analyzer (CDA) instrument aboard the Cassini spacecraft is expected to be placed in orbit about Saturn to sample submicrometer-diameter ring particles and impact ejecta from Saturn's satellites. The CDA measures a mass spectrum of each particle that impacts the chemical analyzer sector of the instrument. Particles impact a Rh target plate at velocities of 1-100 km/s and produce some 10-8 to 10-5 times the particle mass of positive valence, single-charged ions. These are analyzed via a TOF MS. Initial tests employed a pulsed N2 laser acting on samples of kamacite, pyrrhotite, serpentine, olivine, and Murchison meteorite induced bursts of ions which were detected with a microchannel plate and a charge sensitive amplifier (CSA). Pulses from the N2 laser (1011 W/cm2) are assumed to simulate particle impact. Using aluminum alloy as a test sample, each pulse produces a charge of ~4.6 pC (mostly Al+1), whereas irradiation of a stainless steel target produces a ~2.8 pC (Fe+1) charge. Thus the present system yields ~10-5% of the laser energy in resulting ions. A CSA signal indicates that at the position of the microchannel plate, the ion detector geometry is such that some 5% of the laser-induced ions are collected in the CDA geometry. Employing a multichannel plate detector in this MS yields for Al-Mg-Cu alloy and kamacite targets well-defined peaks at 24 (Mg+1), 27(Al+1), and 64 (Cu+1) and 56 (Fe+1), 58 (Ni+1), and 60 (Ni+1) dalton, respectively.

  3. The expanding universe of mass analyzer configurations for biological analysis.

    Science.gov (United States)

    Calvete, Juan J

    2014-01-01

    Mass spectrometry (MS) is an analytical technique that measures the mass-to-charge ratio of electrically charged gas-phase particles. All mass spectrometers combine ion formation, mass analysis, and ion detection. Although mass analyzers can be regarded as sophisticated devices that manipulate ions in space and time, the rich diversity of possible ways to combine ion separation, focusing, and detection in dynamic mass spectrometers accounts for the large number of instrument designs. A historical perspective of the progress in mass spectrometry that since 1965 until today have contributed to position this technique as an indispensable tool for biological research has been recently addressed by a privileged witness of this golden age of MS (Gelpí J. Mass Spectrom 43:419-435, 2008; Gelpí J. Mass Spectrom 44:1137-1161, 2008). The aim of this chapter is to highlight the view that the operational principles of mass spectrometry can be understood by a simple mathematical language, and that an understanding of the basic concepts of mass spectrometry is necessary to take the most out of this versatile technique.

  4. Set-up with electrostatic analyzer for mass spectrometers

    International Nuclear Information System (INIS)

    Ivanov, V.P.; Sysoev, A.A.; Samsonov, G.A.

    1977-01-01

    An attachment with an electrostatic analyzer that enables to implement a double focusing of ion beams when used in conjunction with a magnetic analyzer, is suggested. Used as the electrostatic analyzer is a cylindrical capacitor placed in a vacuum chamber. Apart from this, the attachment includes a vacuum pump, a nitrogen trap, a battery supply unit, one-beam ion receivers and a bellows inlet for capacitor adjustment. All assemblies and parts of the attachment are made of stainless steel. The test of a combined operation of the mass-spactrometer and the attachment indicate that the use of the attachment enables the utilization of sources which form ion beams with an energy dispersion of up to 1.5%, the mass-spectrometer resolving power being unchanged

  5. Mass analyzer ``MASHA'' high temperature target and plasma ion source

    Science.gov (United States)

    Semchenkov, A. G.; Rassadov, D. N.; Bekhterev, V. V.; Bystrov, V. A.; Chizov, A. Yu.; Dmitriev, S. N.; Efremov, A. A.; Guljaev, A. V.; Kozulin, E. M.; Oganessian, Yu. Ts.; Starodub, G. Ya.; Voskresensky, V. M.; Bogomolov, S. L.; Paschenko, S. V.; Zelenak, A.; Tikhonov, V. I.

    2004-05-01

    A new separator and mass analyzer of super heavy atoms (MASHA) has been created at the FLNR JINR Dubna to separate and measure masses of nuclei and molecules with precision better than 10-3. First experiments with the FEBIAD plasma ion source have been done and give an efficiency of ionization of up to 20% for Kr with a low flow test leak (6 particle μA). We suppose a magnetic field optimization, using the additional electrode (einzel lens type) in the extracting system, and an improving of the vacuum conditions in order to increase the ion source efficiency.

  6. Mass analyzer 'MASHA' high temperature target and plasma ion source

    International Nuclear Information System (INIS)

    Semchenkov, A.G.; Rassadov, D.N.; Bekhterev, V.V.; Bystrov, V.A.; Chizov, A.Yu.; Dmitriev, S.N.; Efremov, A.A.; Guljaev, A.V.; Kozulin, E.M.; Oganessian, Yu.Ts.; Starodub, G.Ya.; Voskresensky, V.M.; Bogomolov, S.L.; Paschenko, S.V.; Zelenak, A.; Tikhonov, V.I.

    2004-01-01

    A new separator and mass analyzer of super heavy atoms (MASHA) has been created at the FLNR JINR Dubna to separate and measure masses of nuclei and molecules with precision better than 10 -3 . First experiments with the FEBIAD plasma ion source have been done and give an efficiency of ionization of up to 20% for Kr with a low flow test leak (6 particle μA). We suppose a magnetic field optimization, using the additional electrode (einzel lens type) in the extracting system, and an improving of the vacuum conditions in order to increase the ion source efficiency

  7. Data acquisition and analysis system for the ion microprobe mass analyzer

    International Nuclear Information System (INIS)

    Darby, D.M.; Cristy, S.S.

    1979-02-01

    A computer was interfaced to an ion microprobe mass analyzer for more rapid data acquisition and analysis. The interface is designed to allow data acquisition, independent of the computer. A large data analysis package was developed and implemented. Performance of the computerized system was evaluated and compared to manual operation

  8. Evaluation of the Air Void Analyzer

    Science.gov (United States)

    2013-07-01

    concrete using image analysis: Petrography of cementitious materials. ASTM STP 1215. S.M. DeHayes and D. Stark, eds. Philadelphia, PA: American...Administration (FHWA). 2006. Priority, market -ready technologies and innovations: Air Void Analyzer. Washington D.C. PDF file. Germann Instruments (GI). 2011...tests and properties of concrete and concrete-making materials. STP 169D. West Conshohocken, PA: ASTM International. Magura, D.D. 1996. Air void

  9. The use of mass spectrometry to analyze dried blood spots.

    Science.gov (United States)

    Wagner, Michel; Tonoli, David; Varesio, Emmanuel; Hopfgartner, Gérard

    2016-01-01

    Dried blood spots (DBS) typically consist in the deposition of small volumes of capillary blood onto dedicated paper cards. Comparatively to whole blood or plasma samples, their benefits rely in the fact that sample collection is easier and that logistic aspects related to sample storage and shipment can be relatively limited, respectively, without the need of a refrigerator or dry ice. Originally, this approach has been developed in the sixties to support the analysis of phenylalanine for the detection of phenylketonuria in newborns using bacterial inhibition test. In the nineties tandem mass spectrometry was established as the detection technique for phenylalanine and tyrosine. DBS became rapidly recognized for their clinical value: they were widely implemented in pediatric settings with mass spectrometric detection, and were closely associated to the debut of newborn screening (NBS) programs, as a part of public health policies. Since then, sample collection on paper cards has been explored with various analytical techniques in other areas more or less successfully regarding large-scale applications. Moreover, in the last 5 years a regain of interest for DBS was observed and originated from the bioanalytical community to support drug development (e.g., PK studies) or therapeutic drug monitoring mainly. Those recent applications were essentially driven by improved sensitivity of triple quadrupole mass spectrometers. This review presents an overall view of all instrumental and methodological developments for DBS analysis with mass spectrometric detection, with and without separation techniques. A general introduction to DBS will describe their advantages and historical aspects of their emergence. A second section will focus on blood collection, with a strong emphasis on specific parameters that can impact quantitative analysis, including chromatographic effects, hematocrit effects, blood effects, and analyte stability. A third part of the review is dedicated to

  10. Ion mobility analyzer - quadrupole mass spectrometer system design

    International Nuclear Information System (INIS)

    Cuna, C; Leuca, M; Lupsa, N; Mirel, V; Cuna, Stela; Cosma, V; Tusa, Florina; Bocos-Bintintan, V

    2009-01-01

    Because of their extremely high sensitivity for chemicals with elevated electronegativity or high proton affinity the ion mobility analysers are ideal for the ultra-trace detection of toxic or explosive chemicals, most of these situated often at concentration levels of sub-ppb (parts-per-billion). Ion mobility spectrometers (IMS) can be used to identify illicit drugs or environmental pollutants. Since resolution of an IMS is relatively low, to achieve an accurate identification of target analyte it is recommended to couple the IMS with a quadrupole mass spectrometer (QMS) or a time of flight mass spectrometer, acquiring in this way confirmatory information. This coupling is made through a specific interface. In this paper, an experimental model of such a tandem instrument, IMS-QMS is described. Accomplishment of this general purpose will be done, overcoming a series of specific issues. This implies the solving, using innovative solutions, of a series of complex issues: ensuring the stability of the ions beam generated by ion source; transfer with a good efficiency of the ionic current from IMS analyser to QMS; and realization of a special electronic circuitry which will be able to detect both positive and negative ions.

  11. Ion mobility analyzer - quadrupole mass spectrometer system design

    Energy Technology Data Exchange (ETDEWEB)

    Cuna, C; Leuca, M; Lupsa, N; Mirel, V; Cuna, Stela; Cosma, V; Tusa, Florina [National Institute for Research and Development of Isotopic and Molecular Technologies, 65-103 Donath, 400293 Cluj-Napoca (Romania); Bocos-Bintintan, V, E-mail: cornel.cuna@itim-cj.r [Babes-Bolyai University, Faculty of Environmental Sciences, 3 Fantanele, 400294 Cluj Napoca (Romania)

    2009-08-01

    Because of their extremely high sensitivity for chemicals with elevated electronegativity or high proton affinity the ion mobility analysers are ideal for the ultra-trace detection of toxic or explosive chemicals, most of these situated often at concentration levels of sub-ppb (parts-per-billion). Ion mobility spectrometers (IMS) can be used to identify illicit drugs or environmental pollutants. Since resolution of an IMS is relatively low, to achieve an accurate identification of target analyte it is recommended to couple the IMS with a quadrupole mass spectrometer (QMS) or a time of flight mass spectrometer, acquiring in this way confirmatory information. This coupling is made through a specific interface. In this paper, an experimental model of such a tandem instrument, IMS-QMS is described. Accomplishment of this general purpose will be done, overcoming a series of specific issues. This implies the solving, using innovative solutions, of a series of complex issues: ensuring the stability of the ions beam generated by ion source; transfer with a good efficiency of the ionic current from IMS analyser to QMS; and realization of a special electronic circuitry which will be able to detect both positive and negative ions.

  12. Analyzing mass perceptions of nuclear politics: Puzzling over trust

    International Nuclear Information System (INIS)

    Jenkins-Smith, H.C.; Pratt, D.A.; Bassett, G.W. Jr.

    1994-01-01

    The juxtaposition of public values, trust, and beliefs is at the core of policy-making in democratic political systems, and an accurate understanding of nuclear politics requires that researchers untangle and carefully think about the web of psychological and social influences that shape citizens' preferences. In this paper, we offer some tentative answers about several pieces of the trust open-quotes puzzleclose quotes. First, we reconsider what is meant by open-quotes trustclose quotes and how it is to be measured. We then use telephone survey data to explore the relationship between trust and citizens' nuclear policy preferences. The data lend support to the conclusion that trust is more mutable than previous research has shown, and besides the traditional measure of competence includes aspects of believability and fiduciary competence. The data further indicate that it is a mistake to think in terms of a single open-quotes publicclose quotes when exploring the link between trust and nuclear policies. A number of dissimilar open-quotes publicsclose quotes based on shared open-quotes worldviewsclose quotes or political cultures are apparent in the data analyzed here. These open-quotes publicsclose quotes appear to think about trust differently from one another and rely on different dimensions of trust when determining nuclear policy preferences. Policy-makers must recognize the different open-quotes publicsclose quotes coexisting within the U.S. nuclear policy arena, and the relative import that these publics place on different dimensions of trust

  13. OpenMSI Arrayed Analysis Toolkit: Analyzing Spatially Defined Samples Using Mass Spectrometry Imaging

    Energy Technology Data Exchange (ETDEWEB)

    de Raad, Markus [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); de Rond, Tristan [Univ. of California, Berkeley, CA (United States); Rübel, Oliver [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Keasling, Jay D. [Univ. of California, Berkeley, CA (United States); Joint BioEnergy Inst. (JBEI), Emeryville, CA (United States); Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Technical Univ. of Denmark, Lyngby (Denmark); Northen, Trent R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); USDOE Joint Genome Institute (JGI), Walnut Creek, CA (United States); Bowen, Benjamin P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); USDOE Joint Genome Institute (JGI), Walnut Creek, CA (United States)

    2017-05-03

    Mass spectrometry imaging (MSI) has primarily been applied in localizing biomolecules within biological matrices. Although well-suited, the application of MSI for comparing thousands of spatially defined spotted samples has been limited. One reason for this is a lack of suitable and accessible data processing tools for the analysis of large arrayed MSI sample sets. In this paper, the OpenMSI Arrayed Analysis Toolkit (OMAAT) is a software package that addresses the challenges of analyzing spatially defined samples in MSI data sets. OMAAT is written in Python and is integrated with OpenMSI (http://openmsi.nersc.gov), a platform for storing, sharing, and analyzing MSI data. By using a web-based python notebook (Jupyter), OMAAT is accessible to anyone without programming experience yet allows experienced users to leverage all features. OMAAT was evaluated by analyzing an MSI data set of a high-throughput glycoside hydrolase activity screen comprising 384 samples arrayed onto a NIMS surface at a 450 μm spacing, decreasing analysis time >100-fold while maintaining robust spot-finding. The utility of OMAAT was demonstrated for screening metabolic activities of different sized soil particles, including hydrolysis of sugars, revealing a pattern of size dependent activities. Finally, these results introduce OMAAT as an effective toolkit for analyzing spatially defined samples in MSI. OMAAT runs on all major operating systems, and the source code can be obtained from the following GitHub repository: https://github.com/biorack/omaat.

  14. Evaluation of dominant thyroid masses

    International Nuclear Information System (INIS)

    Thomas, C.G. Jr.; Buckwalter, J.A.; Staab, E.V.; Kerr, C.Y.

    1976-01-01

    Controversy exists concerning the management of solitary thyroid nodules because of conflicting information concerning the high clinical incidence of thyroid nodules, the varying incidence of cancer reported in those surgically excised and the infrequency of death from thyroid cancer. During the past several years, a plan for evaluating patients with dominant thyroid masses has evolved. The objective is to avoid unnecessary operations by identifying patients with a high risk of cancer. The criteria which are used are the age and sex of the patient, the duration of the mass, 125 I or /sup 99m/Tc scans, 75 Selenomethionine scans, B-mode ultrasonography and the response of the mass to suppressive therapy. This is a report of the findings in 222 patients who have been studied employing this approach. Thirty percent of the patients were operated upon. Forty percent had neoplasms (well differentiated cancer--28.8 percent, adenoma--12.1 percent), 47.0 percent--nodular goiter, 6.1 percent cysts, and 6.1 percent chronic thyroiditis. The incidence of cancer in the 222 patients was 8.6 percent and adenoma 3.6 percent. Patients at greatest risk of having cancer are those with solid nonfunctioning nodules which fail to regress with suppressive therapy. This study indicates that the approach described above is effective in selecting for surgical excision those individuals at greatest risk of having thyroid cancer

  15. Comparative evaluation of Plateletworks, Multiplate analyzer and Platelet function analyzer-200 in cardiology patients.

    Science.gov (United States)

    Kim, Jeeyong; Cho, Chi Hyun; Jung, Bo Kyeung; Nam, Jeonghun; Seo, Hong Seog; Shin, Sehyun; Lim, Chae Seung

    2018-04-14

    The objective of this study was to comparatively evaluate three commercial whole-blood platelet function analyzer systems: Platelet Function Analyzer-200 (PFA; Siemens Canada, Mississauga, Ontario, Canada), Multiplate analyzer (MP; Roche Diagnostics International Ltd., Rotkreuz, Switzerland), and Plateletworks Combo-25 kit (PLW; Helena Laboratories, Beaumont, TX, USA). Venipuncture was performed on 160 patients who visited a department of cardiology. Pairwise agreement among the three platelet function assays was assessed using Cohen's kappa coefficient and percent agreement within the reference limit. Kappa values with the same agonists were poor between PFA-collagen (COL; agonist)/adenosine diphosphate (ADP) and MP-ADP (-0.147), PFA-COL/ADP and PLW-ADP (0.089), MP-ADP and PLW-ADP (0.039), PFA-COL/ADP and MP-COL (-0.039), and between PFA-COL/ADP and PLW-COL (-0.067). Nonetheless, kappa values for the same assay principle with a different agonist were slightly higher between PFA-COL/ADP and PFA-COL/EPI (0.352), MP-ADP and MP-COL (0.235), and between PLW-ADP and PLW-COL (0.247). The range of percent agreement values was 38.7% to 73.8%. Therefore, various measurements of platelet function by more than one method were needed to obtain a reliable interpretation of platelet function considering low kappa coefficient and modest percent agreement rates among 3 different platelet function tests.

  16. Evaluation of performance of veterinary in-clinic hematology analyzers.

    Science.gov (United States)

    Rishniw, Mark; Pion, Paul D

    2016-12-01

    A previous study provided information regarding the quality of in-clinic veterinary biochemistry testing. However, no similar studies for in-clinic veterinary hematology testing have been conducted. The objective of this study was to assess the quality of hematology testing in veterinary in-clinic laboratories using results obtained from testing 3 levels of canine EDTA blood samples. Clinicians prepared blood samples to achieve measurand concentrations within, below, and above their RIs and evaluated the samples in triplicate using their in-clinic analyzers. Quality was assessed by comparison of calculated total error with quality requirements, determination of sigma metrics, use of a quality goal index, and agreement between in-clinic and reference laboratory instruments. Suitability for statistical quality control was determined using adaptations from the computerized program, EZRules3. Evaluation of 10 veterinary in-clinic hematology analyzers showed that these instruments often fail to meet quality requirements. At least 60% of analyzers reasonably determined RBC, WBC, HCT, and HGB, when assessed by most quality goal criteria; platelets were less reliably measured, with 80% deemed suitable for low platelet counts, but only 30% for high platelet counts, and automated differential leukocyte counts were generally considered unsuitable for clinical use with fewer than 40% of analyzers meeting the least stringent quality goal requirements. Fewer than 50% of analyzers were able to meet requirements for statistical quality control for any measurand. These findings reflect the current status of in-clinic hematology analyzer performance and provide a basis for future evaluations of the quality of veterinary laboratory testing. © 2016 American Society for Veterinary Clinical Pathology.

  17. Ion optics of a time-of-flight mass spectrometer with electrostatic sector analyzers

    International Nuclear Information System (INIS)

    Sakurai, T.; Ito, H.; Matsuo, T.

    1995-01-01

    The ion optics for a high resolution time-of-flight mass spectrometer with electrostatic sector analyzers have been investigated. The multiple focusing (triple isochronous focusing and triple spacial focusing) conditions can be achieved by using a symmetrical arrangement of the sectors in a mass spectrometer. Both high mass resolution and high ion transmission can be accomplished simultaneously. The principles of MS/MS and MS/MS/MS analyses using a TOF mass spectrometer with electrostatic sector analyzers have been proposed. Product ion spectra can be obtained by measuring the total flight times and the kinetic energy of the products without any additional separation processes, any coincidence techniques or any special timing circuits. In an experiment, MS/MS and MS/MS/MS mass spectra have been obtained. The first generation product ions have been produced by a metastable decay, and the second generation products have been produced by a sequential decay. (orig.)

  18. Evaluation of haematology analyzer CELL-DYN 3700 SL

    Directory of Open Access Journals (Sweden)

    Enver Suljević

    2003-05-01

    Full Text Available Research on the parameters of full blood count and differential white blood count is included in the program of all medical laboratories of primary, secondary and tertiary health care levels. Today, all haematological tests are exclusively performed on the haematology analyzers. Automation of haematology laboratories is a result of the huge requires for haematological test performing, timely issuing of the haematological findings, and possibility of the usage of modern techniques.This work is an evaluation of laser haematology analyzer Cell-Dyn 3700 SL. It investigates the reliability of test results throughout the following parameters: precision, accuracy, sensitivity and specificity of determination methods. It also explores the influence of sample transferring and correlation with haematology analyzer MAXM Retti. Haematology parameters that have been investigated are: white blood cell (WBC, neutrophils (NEU, lymphocytes (LXM, monocytes (MONO, eosinophils (EOS, basophils (BASO, red blood cells (RBC, haemoglobin (HGB, haematocrit (HCT, mean corpuscular volume (MCV, mean corpuscular haemoglobin (MCHC red cell distribution width (RDW, platelet (PLT, mean platelet volume (MPV, plateletocrit (PCT, and platelet distribution width (PDW.The results confirms that precision of analyzer fulfils the reproducibility of testing parameters: WBC, RBC, HGB, MCV, MCH, MCHC, and PLT. Correlation coefficient values (r gained throughout the statistical analysis, that is linear regression results obtained throughout the comparison of two analyzers are adequate except for MCHC (r = 0.64, what is in accordance with literature data.Accuracy is tested by haematology analyzer method and microscopic differentiating method. Correlation coefficient results for granulocytes, lymphocytes and monocytes point the accuracy of methods. Sensitivity and specificity parameters fulfil the analytical criteria.It is confirmed that haematology analyzer Cell-Dyn 3700 SL is reliable for

  19. Sustainability Evaluation of Mass Customization

    DEFF Research Database (Denmark)

    Brunø, Thomas Ditlev; Nielsen, Kjeld; Taps, Stig B.

    2013-01-01

    This paper addresses the issue whether the concepts mass customization and sustainability are fundamentally compatible by asking the question: can a mass customized product be sustainable? Some factors indicate that mass customized products are less sustainable than standardized products; however...... other factors suggest the opposite. This paper explores these factors during three life cycle phases for a product: Production, Use and End of Life. It is concluded that there is not an unambiguous causal relationship between mass customization and sustainability; however several factors unique to mass...... customized products are essential to consider during product development....

  20. Performance evaluation of Samsung LABGEO(HC10) Hematology Analyzer.

    Science.gov (United States)

    Park, Il Joong; Ahn, Sunhyun; Kim, Young In; Kang, Seon Joo; Cho, Sung Ran

    2014-08-01

    The Samsung LABGEO(HC10) Hematology Analyzer (LABGEO(HC10)) is a recently developed automated hematology analyzer that uses impedance technologies. The analyzer provides 18 parameters including 3-part differential at a maximum rate of 80 samples per hour. To evaluate the performance of the LABGEO(HC10). We evaluated precision, linearity, carryover, and relationship for complete blood cell count parameters between the LABGEO(HC10) and the LH780 (Beckman Coulter Inc) in a university hospital in Korea according to the Clinical and Laboratory Standards Institute guidelines. Sample stability and differences due to the anticoagulant used (K₂EDTA versus K₃EDTA) were also evaluated. The LABGEO(HC10) showed linearity over a wide range and minimal carryover ( 0.92) except for mean corpuscular hemoglobin concentration. The bias estimated was acceptable for all parameters investigated except for monocyte count. Most parameters were stable until 24 hours both at room temperature and at 4°C. The difference by anticoagulant type was statistically insignificant for all parameters except for a few red cell parameters. The accurate results achievable and simplicity of operation make the unit recommendable for small to medium-sized laboratories.

  1. The calculus and the design of a miniature quadrupole mass filter: a selected solution from different types of mass analyzers

    International Nuclear Information System (INIS)

    Cuna, C.; Ioanoviciu, D.; Lupsa, N.; Chis, A.

    2002-01-01

    The mass spectrometers are very precise tools used in chemical and isotopic analysis for environmental surveillance. Traditionally environmental analysis is done by sampling the soil, air or water and taking the sample back to the laboratory for analysis. To avoid the difficulties related with the sample alteration during the sampling process and the transport the analysis 'in situ' is to be preferred. This type of analysis combines the sampling and analysis and produces an analytical result almost instantly. Fast-response detection methods are highly desirable in cases where relatively short-lived species are to be examined. Theoretically, any type of mass analyzers can be miniaturized, but some are better suited for miniaturization than others. We studied comparatively different types of mass analyzers that can be miniaturized, especially quadrupole, magnetic sector and time of flight types, in view to select from all these, the best solution for our purpose, the application to the 'in situ' environmental monitoring and inspection, analytical process control. We investigated and calculated the properties of some geometrical arrangements that we reported, one of these being a double focusing mass analyzer with electric deflector and magnetic deflector combined in a reversed geometry. From the different calculated versions we selected the following one, with the characteristic parameters: n = 62, f = 2 MHz, L = 0.07 m, r 0 = 2.616 x 10 -3 m, E z = 5 V, R housing = 3.5 r 0 , V m = 1000 V, R max = 200, M max = 200 u. Starting from these mechanical and electrical parameters we calculated and designed a miniature quadrupole mass spectrometer. A theoretical study of the ion trajectories in the quadrupole analyzer by matrix formalism as well as by using Mathieu functions was made. Using the program SIMION 6, the trajectories inside the quadrupole filter were also simulated. The calculus of the ion trajectories starts by numerically solving of the Mathieu type equation

  2. Performance Evaluation of the Sysmex CS-5100 Automated Coagulation Analyzer.

    Science.gov (United States)

    Chen, Liming; Chen, Yu

    2015-01-01

    Coagulation testing is widely applied clinically, and laboratories increasingly demand automated coagulation analyzers with short turn-around times and high-throughput. The purpose of this study was to evaluate the performance of the Sysmex CS-5100 automated coagulation analyzer for routine use in a clinical laboratory. The prothrombin time (PT), international normalized ratio (INR), activated partial thromboplastin time (APTT), fibrinogen (Fbg), and D-dimer were compared between the Sysmex CS-5100 and Sysmex CA-7000 analyzers, and the imprecision, comparison, throughput, STAT function, and performance for abnormal samples were measured in each. The within-run and between-run coefficients of variation (CV) for the PT, APTT, INR, and D-dimer analyses showed excellent results both in the normal and pathologic ranges. The correlation coefficients between the Sysmex CS-5100 and Sysmex CA-7000 were highly correlated. The throughput of the Sysmex CS-5100 was faster than that of the Sysmex CA-7000. There was no interference at all by total bilirubin concentrations and triglyceride concentrations in the Sysmex CS-5100 analyzer. We demonstrated that the Sysmex CS-5100 performs with satisfactory imprecision and is well suited for coagulation analysis in laboratories processing large sample numbers and icteric and lipemic samples.

  3. Atomic masses 1995. The 1995 atomic mass evaluation

    International Nuclear Information System (INIS)

    Audi, G.; Wapstra, A.H.

    1995-01-01

    The 1995 atomic mass evaluation by G. Audi and A.H. Wapstra is documented. The resulting data files containing recommended values of atomic masses, obtained by experiment or systematics, and related data such as reaction and separation energies are described. The data files can be obtained through online services from several nuclear data centers or on magnetic tape, free of charge. (author)

  4. Atomic masses 1993. The 1993 atomic mass evaluation

    International Nuclear Information System (INIS)

    Audi, G.; Wapstra, A.H.

    1993-01-01

    The 1993 atomic mass evaluation by G. Audi and A.H. Wapstra is documented. The resulting data files containing recommended values of atomic masses, obtained by experiment of systematics, and related data such as reaction and separation energies are described. The data files can be obtained through online services from several nuclear data centers or on magnetic tape, free of charge. (author)

  5. Innovative application of the moisture analyzer for determination of dry mass content of processed cheese

    Science.gov (United States)

    Kowalska, Małgorzata; Janas, Sławomir; Woźniak, Magdalena

    2018-04-01

    The aim of this work was the presentation of an alternative method of determination of the total dry mass content in processed cheese. The authors claim that the presented method can be used in industry's quality control laboratories for routine testing and for quick in-process control. For the test purposes both reference method of determination of dry mass in processed cheese and moisture analyzer method were used. The tests were carried out for three different kinds of processed cheese. In accordance with the reference method, the sample was placed on a layer of silica sand and dried at the temperature of 102 °C for about 4 h. The moisture analyzer test required method validation, with regard to drying temperature range and mass of the analyzed sample. Optimum drying temperature of 110 °C was determined experimentally. For Hochland cream processed cheese sample, the total dry mass content, obtained using the reference method, was 38.92%, whereas using the moisture analyzer method, it was 38.74%. An average analysis time in case of the moisture analyzer method was 9 min. For the sample of processed cheese with tomatoes, the reference method result was 40.37%, and the alternative method result was 40.67%. For the sample of cream processed cheese with garlic the reference method gave value of 36.88%, and the alternative method, of 37.02%. An average time of those determinations was 16 min. Obtained results confirmed that use of moisture analyzer is effective. Compliant values of dry mass content were obtained for both of the used methods. According to the authors, the fact that the measurement took incomparably less time for moisture analyzer method, is a key criterion of in-process control and final quality control method selection.

  6. Time-of-flight SIMS/MSRI reflectron mass analyzer and method

    Science.gov (United States)

    Smentkowski, Vincent S.; Gruen, Dieter M.; Krauss, Alan R.; Schultz, J. Albert; Holecek, John C.

    1999-12-28

    A method and apparatus for analyzing the surface characteristics of a sample by Secondary Ion Mass Spectroscopy (SIMS) and Mass Spectroscopy of Recoiled Ions (MSRI) is provided. The method includes detecting back scattered primary ions, low energy ejected species, and high energy ejected species by ion beam surface analysis techniques comprising positioning a ToF SIMS/MSRI mass analyzer at a predetermined angle .theta., where .theta. is the angle between the horizontal axis of the mass analyzer and the undeflected primary ion beam line, and applying a specific voltage to the back ring of the analyzer. Preferably, .theta. is less than or equal to about 120.degree. and, more preferably, equal to 74.degree.. For positive ion analysis, the extractor, lens, and front ring of the reflectron are set at negative high voltages (-HV). The back ring of the reflectron is set at greater than about +700V for MSRI measurements and between the range of about +15 V and about +50V for SIMS measurements. The method further comprises inverting the polarity of the potentials applied to the extractor, lens, front ring, and back ring to obtain negative ion SIMS and/or MSRI data.

  7. MS2Analyzer: A Software for Small Molecule Substructure Annotations from Accurate Tandem Mass Spectra

    Science.gov (United States)

    2015-01-01

    Systematic analysis and interpretation of the large number of tandem mass spectra (MS/MS) obtained in metabolomics experiments is a bottleneck in discovery-driven research. MS/MS mass spectral libraries are small compared to all known small molecule structures and are often not freely available. MS2Analyzer was therefore developed to enable user-defined searches of thousands of spectra for mass spectral features such as neutral losses, m/z differences, and product and precursor ions from MS/MS spectra in MSP/MGF files. The software is freely available at http://fiehnlab.ucdavis.edu/projects/MS2Analyzer/. As the reference query set, 147 literature-reported neutral losses and their corresponding substructures were collected. This set was tested for accuracy of linking neutral loss analysis to substructure annotations using 19 329 accurate mass tandem mass spectra of structurally known compounds from the NIST11 MS/MS library. Validation studies showed that 92.1 ± 6.4% of 13 typical neutral losses such as acetylations, cysteine conjugates, or glycosylations are correct annotating the associated substructures, while the absence of mass spectra features does not necessarily imply the absence of such substructures. Use of this tool has been successfully demonstrated for complex lipids in microalgae. PMID:25263576

  8. Evaluation of Virtual Refrigerant Mass Flow Sensors

    OpenAIRE

    Kim, Woohyun; Braun, James E.

    2012-01-01

    Refrigerant mass flow rate is an important measurement for monitoring equipment performance and enabling fault detection and diagnostics. However, a traditional mass flow meter is expensive to purchase and install. A virtual refrigerant mass flow sensor (VRMF) uses a mathematical model to estimate flow rate using low-cost measurements and can potentially be implemented at low cost. This study evaluates three VRMFs for estimating refrigerant mass flow rate. The first model uses a compressor ma...

  9. Turning an energy analyzer into a mass spectrometer and a charge sorter

    International Nuclear Information System (INIS)

    Lee, K.

    2004-01-01

    Full text:When a swarm of ions are accelerated by a pulsed electric field for a common duration before entering an electrostatically dispersive energy analyzer, they will be sorted according to their charge-to-mass ratio q/m. In other words, the apparent kinetic energy upon which an ion will be registered in an apparent 'energy' spectrum thus obtained is proportional to its q/m ratio. For ions of a fixed mass m, the apparent energy spectrum becomes a charge state distribution spectrum. For ions of a fixed charge q, the apparent energy spectrum becomes a mass spectrum. In essence, an energy analyzer becomes both a charge sorter and a mass spectrometer when operated in this mode. When this technique is brought to bear on the detection of photofragment ions, a distinct advantage emerges. Kinetic energy release distribution (KERD) of fragment ions conventionally is extracted from fitting of the ion time-of-flight profile to ion trajectory simulation results, as such a fair amount of uncertainty exists in the KERD thus obtained. With the current novel approach to mass spectrometry, the KERDs of photofragment ions can be obtained directly, and as a result, with a greater accuracy. This should advance the study of fragmentation dynamics considerably

  10. Evaluation of Rheological Properties of Apple Mass Based Desserts

    OpenAIRE

    Sigita Boca; Ruta Galoburda; Inta Krasnova; Dalija Seglina; Aivars Aboltins; Imants Skrupskis

    2013-01-01

    The aim of the study was to evaluate the effect of texturizers on the rheological properties of the apple mass and desserts made from various raw materials. The apple varieties - ‘Antonovka’, ‘Baltais Dzidrais’, and ‘Zarja Alatau’ harvested in Latvia, were used for the experiment. The apples were processed in a blender unpeeled for obtaining a homogenous mass. The apple mass was analyzed fresh and after storage at –18ºC. Both fresh and thawed apple mass samples with added...

  11. OpenMSI Arrayed Analysis Toolkit: Analyzing Spatially Defined Samples Using Mass Spectrometry Imaging

    DEFF Research Database (Denmark)

    de Raad, Markus; de Rond, Tristan; Rübel, Oliver

    2017-01-01

    ://openmsinersc.gov), a platform for storing, sharing, and analyzing MSI data. By using a web-based python notebook (Jupyter), OMAAT is accessible to anyone without programming experience yet allows experienced users to leverage all features. OMAAT was :evaluated by analyzing an MSI data set of a high-throughput glycoside...... processing tools for the analysis of large arrayed MSI sample sets. The OpenMSI Arrayed Analysis Toolkit (OMAAT) is a software package that addresses the challenges of analyzing spatially defined samples in MSI data sets. OMAAT is written in Python and is integrated with OpenMSI (http...

  12. Optimizing recoil-isomer tagging with the Argonne fragment mass analyzer

    International Nuclear Information System (INIS)

    Garnsworthy, A.B.; Lister, C.J.; Regan, P.H.; Blank, B.B.; Cullen, I.J.; Gros, S.; Henderson, D.J.; Jones, G.A.; Liu, Z.; Seweryniak, D.; Shumard, B.R.; Thompson, N.J.; Williams, S.J.; Zhu, S.

    2008-01-01

    A new focal plane detector arrangement for the Fragment Mass Analyzer (FMA) has been built and tested at Argonne National Laboratory. This set-up is particularly sensitive for performing Recoil-Isomer Tagging on nuclei with isomeric states with lifetimes in the microsecond range. Recoiling nuclei from fusion-evaporation reactions at the target position are dispersed by their ratio of mass to charge (A/q) by the FMA and stopped in low pressure gas (air) at the focal plane. Subsequent gamma decays from isomeric states in the reaction products are observed using Ge detectors. A constant gas flow through the focal plane chamber efficiently removes longer-lived beta-decaying species from sight of the detectors. This set-up has been commissioned successfully with the microsecond isomer in 80 Rb, populated via the 52 Cr( 32 S, 3pn) reaction at 135 MeV

  13. Isotope ratio analysis by a combination of element analyzer and mass spectrometer

    International Nuclear Information System (INIS)

    Pichlmayer, F.

    1987-06-01

    The use of stable isotope ratios of carbon, nitrogen and sulfur as analytical tool in many fields of research is of growing interest. A method has therefore been developed, consisting in essential of coupling an Elemental Analyzer with an Isotope Mass Spectrometer, which enables the gas preparation of carbon dioxide, nitrogen and sulfur dioxide from any solid or liquid sample in a fast and easy way. Results of carbon isotope measurements in food analysis are presented, whereat it is possible to check origin and treatment of sugar, oils, fats, mineral waters, spirituous liquors etc. and to detect adulterations as well. Also applications in the field of environmental research are given. (Author)

  14. Measuring and Analyzing the Scholarly Impact of Experimental Evaluation Initiatives

    DEFF Research Database (Denmark)

    Angelini, Marco; Ferro, Nicola; Larsen, Birger

    2014-01-01

    Evaluation initiatives have been widely credited with contributing highly to the development and advancement of information access systems, by providing a sustainable platform for conducting the very demanding activity of comparable experimental evaluation in a large scale. Measuring the impact...

  15. Aluminum surface modification by a non-mass-analyzed nitrogen ion beam

    Science.gov (United States)

    Ohira, Shigeo; Iwaki, Masaya

    Non-mass-analyzed nitrogen ion implantation into polycrystal and single crystal aluminum sheets has been carried out at an accelerating voltage of 90 kV and a dose of 1 × 10 18 N ions/cm 2 using a Zymet implanter model Z-100. The pressure during implantation rose to 10 -3 Pa due to the influence of N gas feeding into the ion source. The characteristics of the surface layers were investigated by means of Auger electron spectroscopy (AES), X-ray diffraction (XRD), transmission electron diffraction (TED), and microscopy (TEM). The AES depth profiling shows a rectangular-like distribution of N atoms and little migration of O atoms near the surface. The high dose N-implantation forms c-axis oriented aluminum nitride (AIN) crystallines, and especially irradiation of Al single crystals with N ions leads to the formation of a hcp AlN single crystal. It is concluded that the high dose N-implantation in Al can result in the formation of AlN at room temperature without any thermal annealing. Furthermore, non-mass-analyzed N-implantation at a pressure of 10 -3 Pa of the nitrogen atmosphere causes the formation of pure AlN single crystals in the Al surface layer and consequently it can be practically used for AlN production.

  16. Evaluation of the three-nucleon analyzing power puzzle

    International Nuclear Information System (INIS)

    Tornow, W.; Witala, H.

    1998-01-01

    The current status of the three-nucleon analyzing power puzzle is reviewed. Applying tight constraints on the allowed deviations between calculated predictions and accepted values for relevant nucleon-nucleon observables reveals that energy independent correction factors applied to the 3 P j nucleon-nucleon interactions can not solve the puzzle. Furthermore, using the same constraints, charge-independence breaking in the 3 P j nucleon-nucleon interactions can be ruled out as a possible tool to improve the agreement between three-nucleon calculations and data. The study of the energy dependence of the three-nucleon analyzing power puzzle gives clear evidence that the 3 P j nucleon-nucleon interaction obtained from phase-shift analyses and used in potential models are correct above about 25 MeV, i.e., the 3 P j nucleon-nucleon interactions have to be modified only at lower energies in order to solve the three-nucleon analyzing power puzzle, unless new three-nucleon forces can be found that account for the three-nucleon analyzing power puzzle without destroying the beautiful agreement between rigorous three-nucleon calculations and a large body of accurate three-nucleon data. (orig.)

  17. Evaluation of the three-nucleon analyzing power puzzle

    Energy Technology Data Exchange (ETDEWEB)

    Tornow, W. [Duke Univ., Durham, NC (United States). Dept. of Physics]|[Triangle Univ. Nuclear Lab., Durham, NC (United States); Witala, H. [Uniwersytet Jagiellonski, Cracow (Poland). Inst. Fizyki

    1998-07-20

    The current status of the three-nucleon analyzing power puzzle is reviewed. Applying tight constraints on the allowed deviations between calculated predictions and accepted values for relevant nucleon-nucleon observables reveals that energy independent correction factors applied to the {sup 3}P{sub j} nucleon-nucleon interactions can not solve the puzzle. Furthermore, using the same constraints, charge-independence breaking in the {sup 3}P{sub j} nucleon-nucleon interactions can be ruled out as a possible tool to improve the agreement between three-nucleon calculations and data. The study of the energy dependence of the three-nucleon analyzing power puzzle gives clear evidence that the {sup 3}P{sub j} nucleon-nucleon interaction obtained from phase-shift analyses and used in potential models are correct above about 25 MeV, i.e., the {sup 3}P{sub j} nucleon-nucleon interactions have to be modified only at lower energies in order to solve the three-nucleon analyzing power puzzle, unless new three-nucleon forces can be found that account for the three-nucleon analyzing power puzzle without destroying the beautiful agreement between rigorous three-nucleon calculations and a large body of accurate three-nucleon data. (orig.) 18 refs.

  18. Multidimensional journal evaluation analyzing scientific periodicals beyond the impact factor

    CERN Document Server

    Haustein, Stefanie

    2012-01-01

    Scientific communication depends primarily on publishing in journals. The most important indicator to determine the influence of a journal is the Impact Factor. Since this factor only measures the average number of citations per article in a certain time window, it can be argued that it does not reflect the actual value of a periodical. This book defines five dimensions, which build a framework for a multidimensional method of journal evaluation. The author is winner of the Eugene Garfield Doctoral Dissertation Scholarship 2011.

  19. Study of impurities in Aditya Tokamak during different conditions using quadrupole mass analyzer

    International Nuclear Information System (INIS)

    Bhatt, S.B.; Jadeja, K.A.; Patel, K.M.; Patel, N.D.; Raval, M.K.; Ghosh, J.

    2015-01-01

    In fusion devices, e.g., Tokamak, the presence of the impurities, i.e. gas species other than the fuel gas, deteriorates plasma and makes confinement difficult. The gas molecules tend to get adsorbed on the surfaces of the solid state materials of the vessel wall during discharges. A Residual Gas Analyzer (RGA) is the most commonly useful instrument to measure the presence and quantity of the various gases in a vacuum system. Quadrupole Mass Analyzer (QMA) is installed on Aditya Tokamak to measure the concentrations of various gas species present in Aditya vacuum system. It is also used to monitor impurities generated during various phases of discharges in Aditya Tokamak. The impurities are reduced by various types of discharge cleaning and in-situ coatings. Presence of residual gas concentration in vacuum system creates limitation for achievement of ultrahigh vacuum and also affects plasma performance. The presence of residual gases is due to different reasons like atmospheric concentration, contamination of the wall materials, outgassing from the exposed materials, permeation, real and virtual leaks

  20. Evaluation of system codes for analyzing naturally circulating gas loop

    International Nuclear Information System (INIS)

    Lee, Jeong Ik; No, Hee Cheon; Hejzlar, Pavel

    2009-01-01

    Steady-state natural circulation data obtained in a 7 m-tall experimental loop with carbon dioxide and nitrogen are presented in this paper. The loop was originally designed to encompass operating range of a prototype gas-cooled fast reactor passive decay heat removal system, but the results and conclusions are applicable to any natural circulation loop operating in regimes having buoyancy and acceleration parameters within the ranges validated in this loop. Natural circulation steady-state data are compared to numerical predictions by two system analysis codes: GAMMA and RELAP5-3D. GAMMA is a computational tool for predicting various transients which can potentially occur in a gas-cooled reactor. The code has a capability of analyzing multi-dimensional multi-component mixtures and includes models for friction, heat transfer, chemical reaction, and multi-component molecular diffusion. Natural circulation data with two gases show that the loop operates in the deteriorated turbulent heat transfer (DTHT) regime which exhibits substantially reduced heat transfer coefficients compared to the forced turbulent flow. The GAMMA code with an original heat transfer package predicted conservative results in terms of peak wall temperature. However, the estimated peak location did not successfully match the data. Even though GAMMA's original heat transfer package included mixed-convection regime, which is a part of the DTHT regime, the results showed that the original heat transfer package could not reproduce the data with sufficient accuracy. After implementing a recently developed correlation and corresponding heat transfer regime map into GAMMA to cover the whole range of the DTHT regime, we obtained better agreement with the data. RELAP5-3D results are discussed in parallel.

  1. A Dual Source Ion Trap Mass Spectrometer for the Mars Organic Molecule Analyzer of ExoMars 2018

    Science.gov (United States)

    Brickerhoff, William B.; vanAmerom, F. H. W.; Danell, R. M.; Arevalo, R.; Atanassova, M.; Hovmand, L.; Mahaffy, P. R.; Cotter, R. J.

    2011-01-01

    We present details on the objectives, requirements, design and operational approach of the core mass spectrometer of the Mars Organic Molecule Analyzer (MOMA) investigation on the 2018 ExoMars mission. The MOMA mass spectrometer enables the investigation to fulfill its objective of analyzing the chemical composition of organic compounds in solid samples obtained from the near surface of Mars. Two methods of ionization are realized, associated with different modes of MOMA operation, in a single compact ion trap mass spectrometer. The stringent mass and power constraints of the mission have led to features such as low voltage and low frequency RF operation [1] and pulse counting detection.

  2. Using Outcomes to Analyze Patients Rather than Patients to Analyze Outcomes: A Step toward Pragmatism in Benefit:risk Evaluation

    Science.gov (United States)

    Evans, Scott R.; Follmann, Dean

    2016-01-01

    In the future, clinical trials will have an increased emphasis on pragmatism, providing a practical description of the effects of new treatments in realistic clinical settings. Accomplishing pragmatism requires better summaries of the totality of the evidence in ways that clinical trials consumers---patients, physicians, insurers---find transparent and allow for informed benefit:risk decision-making. The current approach to the analysis of clinical trials is to analyze efficacy and safety separately and then combine these analyses into a benefit:risk assessment. Many assume that this will effectively describe the impact on patients. But this approach is suboptimal for evaluating the totality of effects on patients. We discuss methods for benefit:risk assessment that have greater pragmatism than methods that separately analyze efficacy and safety. These include the concepts of within-patient analyses and composite benefit:risk endpoints with a goal of understanding how to analyze one patient before trying to figure out how to analyze many. We discuss the desirability of outcome ranking (DOOR) and introduce the partial credit strategy using an example in a clinical trial evaluating the effects of a new antibiotic. As part of the example we introduce a strategy to engage patients as a resource to inform benefit:risk analyses consistent with the goal of measuring and weighing outcomes that are most important from the patient’s perspective. We describe a broad vision for the future of clinical trials consistent with increased pragmatism. Greater focus on using endpoints to analyze patients rather than patients to analyze endpoints particularly in late-phase/stage clinical trials is an important part of this vision. PMID:28435515

  3. Quality evaluation of tandem mass spectral libraries.

    Science.gov (United States)

    Oberacher, Herbert; Weinmann, Wolfgang; Dresen, Sebastian

    2011-06-01

    Tandem mass spectral libraries are gaining more and more importance for the identification of unknowns in different fields of research, including metabolomics, forensics, toxicology, and environmental analysis. Particularly, the recent invention of reliable, robust, and transferable libraries has increased the general acceptance of these tools. Herein, we report on results obtained from thorough evaluation of the match reliabilities of two tandem mass spectral libraries: the MSforID library established by the Oberacher group in Innsbruck and the Weinmann library established by the Weinmann group in Freiburg. Three different experiments were performed: (1) Spectra of the libraries were searched against their corresponding library after excluding either this single compound-specific spectrum or all compound-specific spectra prior to searching; (2) the libraries were searched against each other using either library as reference set or sample set; (3) spectra acquired on different mass spectrometric instruments were matched to both libraries. Almost 13,000 tandem mass spectra were included in this study. The MSforID search algorithm was used for spectral matching. Statistical evaluation of the library search results revealed that principally both libraries enable the sensitive and specific identification of compounds. Due to higher mass accuracy of the QqTOF compared with the QTrap instrument, matches to the MSforID library were more reliable when comparing spectra with both libraries. Furthermore, only the MSforID library was shown to be efficiently transferable to different kinds of tandem mass spectrometers, including "tandem-in-time" instruments; this is due to the coverage of a large range of different collision energy settings-including the very low range-which is an outstanding characteristics of the MSforID library.

  4. A Method for Analyzing the Dynamic Response of a Structural System with Variable Mass, Damping and Stiffness

    Directory of Open Access Journals (Sweden)

    Mike D.R. Zhang

    2001-01-01

    Full Text Available In this paper, a method for analyzing the dynamic response of a structural system with variable mass, damping and stiffness is first presented. The dynamic equations of the structural system with variable mass and stiffness are derived according to the whole working process of a bridge bucket unloader. At the end of the paper, an engineering numerical example is given.

  5. Congenital cystic masses of the face and neck: CT evaluation

    International Nuclear Information System (INIS)

    Chung, Hae Gyeong; Kim, Hyung Jin; Kim, Jae Hyoung; Hwang, Eui Gee; Jeon, Sea Young; Kim, Sun Young; Chung, Sung Hoon

    1991-01-01

    Recognition of the congenital cystic masses of the face and neck is important because they are usually benign, and can be completely cured by surgical excision. We retrospective analyzed CT scan of 18 surgically proven congenital cystic masses of the face and neck. The cases included 5 thyroglossal duct cysts, 4 cystic hygromas, 5 dermoid cysts, 1 branchial cleft cyst, and 3 fissural cysts of the face. Of five cases of thyroglossal duct cysts, CT showed either a well-marginated, rim enhancing unilocular cystic mass (n=3), or a diffuse but heterogeneous highly enhancing soft tissue mass (n=2). The latter two cases were confirmed later as infected thyroglossal duct cysts. Four cases of cystic hygromas were seen as either an irregularly-marginated (n=3) or a well-marginated (n=1) rim enhancing multiseptated cystic mass with a fluid-fluid level. Five cases of dermoid cysts appeared as well-marginated rim enhancing unilocular ovoid masses. The content of each mass was predominantly fluid in four cases, of which additional solid components were found in two, and interspersed fat globules in one. One case was composed of a homogeneous fatty density. One case of branchial cleft cyst was in the anterior triangle near the left mandibular angle, and appeared as a well-marginated enhancing cystic mass with a thick rim. In this case displacement of the adjacent structures was noted also. All three cases of fissural cysts of the face were seen as a well-marginated, rim enhancing cystic mass, causing a smooth pressure erosion of the adjacent bones. We conclude that CT is useful for the evaluation of the congenital cystic masses of the face and neck, because it can differentiate various forms of the congenital lesions and is able to clearly reveal the relation of the mass to the adjacent structures

  6. Congenital cystic masses of the face and neck: CT evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Hae Gyeong; Kim, Hyung Jin; Kim, Jae Hyoung; Hwang, Eui Gee; Jeon, Sea Young; Kim, Sun Young; Chung, Sung Hoon [Gyeongsang National University, Jinju (Korea, Republic of)

    1991-09-15

    Recognition of the congenital cystic masses of the face and neck is important because they are usually benign, and can be completely cured by surgical excision. We retrospective analyzed CT scan of 18 surgically proven congenital cystic masses of the face and neck. The cases included 5 thyroglossal duct cysts, 4 cystic hygromas, 5 dermoid cysts, 1 branchial cleft cyst, and 3 fissural cysts of the face. Of five cases of thyroglossal duct cysts, CT showed either a well-marginated, rim enhancing unilocular cystic mass (n=3), or a diffuse but heterogeneous highly enhancing soft tissue mass (n=2). The latter two cases were confirmed later as infected thyroglossal duct cysts. Four cases of cystic hygromas were seen as either an irregularly-marginated (n=3) or a well-marginated (n=1) rim enhancing multiseptated cystic mass with a fluid-fluid level. Five cases of dermoid cysts appeared as well-marginated rim enhancing unilocular ovoid masses. The content of each mass was predominantly fluid in four cases, of which additional solid components were found in two, and interspersed fat globules in one. One case was composed of a homogeneous fatty density. One case of branchial cleft cyst was in the anterior triangle near the left mandibular angle, and appeared as a well-marginated enhancing cystic mass with a thick rim. In this case displacement of the adjacent structures was noted also. All three cases of fissural cysts of the face were seen as a well-marginated, rim enhancing cystic mass, causing a smooth pressure erosion of the adjacent bones. We conclude that CT is useful for the evaluation of the congenital cystic masses of the face and neck, because it can differentiate various forms of the congenital lesions and is able to clearly reveal the relation of the mass to the adjacent structures.

  7. Magnetic Resonance Imaging Evaluation of Cardiac Masses

    International Nuclear Information System (INIS)

    Braggion-Santos, Maria Fernanda; Koenigkam-Santos, Marcel; Teixeira, Sara Reis; Volpe, Gustavo Jardim; Trad, Henrique Simão; Schmidt, André

    2013-01-01

    Cardiac tumors are extremely rare; however, when there is clinical suspicion, proper diagnostic evaluation is necessary to plan the most appropriate treatment. In this context, cardiovascular magnetic resonance imaging (CMRI) plays an important role, allowing a comprehensive characterization of such lesions. To review cases referred to a CMRI Department for investigation of cardiac and paracardiac masses. To describe the positive case series with a brief review of the literature for each type of lesion and the role of cardiovascular magnetic resonance imaging in evaluation. Between August 2008 and December 2011, all cases referred for CMRI with suspicion of tumor involving the heart were reviewed. Cases with positive histopathological diagnosis, clinical evolution or therapeutic response compatible with the clinical suspicion and imaging findings were selected. Among the 13 cases included in our study, eight (62%) had histopathological confirmation. We describe five benign tumors (myxomas, rhabdomyoma and fibromas), five malignancies (sarcoma, lymphoma, Richter syndrome involving the heart and metastatic disease) and three non-neoplastic lesions (pericardial cyst, intracardiac thrombus and infectious vegetation). CMRI plays an important role in the evaluation of cardiac masses of non-neoplastic and neoplastic origin, contributing to a more accurate diagnosis in a noninvasive manner and assisting in treatment planning, allowing safe clinical follow-up with good reproducibility

  8. An optimized two-step derivatization method for analyzing diethylene glycol ozonation products using gas chromatography and mass spectrometry.

    Science.gov (United States)

    Yu, Ran; Duan, Lei; Jiang, Jingkun; Hao, Jiming

    2017-03-01

    The ozonation of hydroxyl compounds (e.g., sugars and alcohols) gives a broad range of products such as alcohols, aldehydes, ketones, and carboxylic acids. This study developed and optimized a two-step derivatization procedure for analyzing polar products of aldehydes and carboxylic acids from the ozonation of diethylene glycol (DEG) in a non-aqueous environment using gas chromatography-mass spectrometry. Experiments based on Central Composite Design with response surface methodology were carried out to evaluate the effects of derivatization variables and their interactions on the analysis. The most desirable derivatization conditions were reported, i.e., oximation was performed at room temperature overnight with the o-(2,3,4,5,6-pentafluorobenzyl) hydroxyl amine to analyte molar ratio of 6, silylation reaction temperature of 70°C, reaction duration of 70min, and N,O-bis(trimethylsilyl)-trifluoroacetamide volume of 12.5μL. The applicability of this optimized procedure was verified by analyzing DEG ozonation products in an ultrafine condensation particle counter simulation system. Copyright © 2016. Published by Elsevier B.V.

  9. Dust coma of Halley comet: measurements with the dust counter and mass analyzer (DUSMA)

    International Nuclear Information System (INIS)

    Simpson, J.A.; Sagdeev, R.Z.; Tuzzolino, A.J.; AN SSSR, Moscow. Inst. Kosmicheskikh Issledovanij)

    1986-01-01

    The paper represents a preliminary report on measurements of spatial and temporal distribution of mass and flows of dust particles coming from comet nucleus performed by means of devices constructed on the new principle of detecting comet dust specks. The device has a high time resolution (∼ 4 μs) in the wide range of mass and dust flows. On the base of a preliminary analysis the following conclusions are drawn: dust coma in quiet state (''Vega-2'') as well as at the presence of considerable emissions (''Vega-1'') manifests the presence of important short-term out-bursts having by time a quasi-periodic structure. Integral mass spectra show flows intensity growth with the decrease of measured mass (which contradicts some theoretical models). Flow levels lie approximately in the region previously determined by ground observations. The coma is extremely dynamic both in space and in time which proves the complex structure of regions of dust emission from the nucleus

  10. Performance evaluation of enzyme immunoassay for voriconazole therapeutic drug monitoring with automated clinical chemistry analyzers

    Directory of Open Access Journals (Sweden)

    Yongbum Jeon

    2017-08-01

    Full Text Available Objective: Voriconazole is a triazole antifungal developed for the treatment of fungal infectious disease, and the clinical utility of its therapeutic drug monitoring has been evaluated. Recently, a new assay for analyzing the serum voriconazole concentration with an automated clinical chemistry analyzer was developed. We evaluated the performance of the new assay based on standardized protocols. Methods: The analytical performance of the assay was evaluated according to its precision, trueness by recovery, limit of quantitation, linearity, and correlation with results from liquid chromatography-tandem mass spectrometry (LC-MS/MS. The evaluation was performed with the same protocol on two different routine chemistry analyzers. All evaluations were performed according to CLSI Guidelines EP15, EP17, EP6, and EP9 [1–4]. Results: Coefficients of variation for within-run and between-day imprecision were 3.2–5.1% and 1.5–3.0%, respectively, on the two different analyzers for pooled serum samples. The recovery rates were in the range of 95.4–102.2%. The limit of blank was 0.0049 μg/mL, and the limit of detection of the samples was 0.0266–0.0376 μg/mL. The percent recovery at three LoQ levels were 67.9–74.6% for 0.50 μg/mL, 75.5–80.2% for 0.60 μg/mL, and 89.9–96.6% for 0.70 μg/mL. A linear relationship was demonstrated between 0.5 μg/mL and 16.0 μg/mL (R2=0.9995–0.9998. The assay correlated well with LC-MS/MS results (R2=0.9739–0.9828. Conclusions: The assay showed acceptable precision, trueness, linearity, and limit of quantification, and correlated well with LC-MS/MS. Therefore, its analytical performance is satisfactory for monitoring the drug concentration of voriconazole. Keywords: Voriconazole, Antifungal agents, Therapeutic drug monitoring

  11. Performance evaluation of enzyme immunoassay for voriconazole therapeutic drug monitoring with automated clinical chemistry analyzers.

    Science.gov (United States)

    Jeon, Yongbum; Han, Minje; Han, Eun Young; Lee, Kyunghoon; Song, Junghan; Song, Sang Hoon

    2017-08-01

    Voriconazole is a triazole antifungal developed for the treatment of fungal infectious disease, and the clinical utility of its therapeutic drug monitoring has been evaluated. Recently, a new assay for analyzing the serum voriconazole concentration with an automated clinical chemistry analyzer was developed. We evaluated the performance of the new assay based on standardized protocols. The analytical performance of the assay was evaluated according to its precision, trueness by recovery, limit of quantitation, linearity, and correlation with results from liquid chromatography-tandem mass spectrometry (LC-MS/MS). The evaluation was performed with the same protocol on two different routine chemistry analyzers. All evaluations were performed according to CLSI Guidelines EP15, EP17, EP6, and EP9 [1-4]. Coefficients of variation for within-run and between-day imprecision were 3.2-5.1% and 1.5-3.0%, respectively, on the two different analyzers for pooled serum samples. The recovery rates were in the range of 95.4-102.2%. The limit of blank was 0.0049 μg/mL, and the limit of detection of the samples was 0.0266-0.0376 μg/mL. The percent recovery at three LoQ levels were 67.9-74.6% for 0.50 μg/mL, 75.5-80.2% for 0.60 μg/mL, and 89.9-96.6% for 0.70 μg/mL. A linear relationship was demonstrated between 0.5 μg/mL and 16.0 μg/mL ( R 2 =0.9995-0.9998). The assay correlated well with LC-MS/MS results ( R 2 =0.9739-0.9828). The assay showed acceptable precision, trueness, linearity, and limit of quantification, and correlated well with LC-MS/MS. Therefore, its analytical performance is satisfactory for monitoring the drug concentration of voriconazole.

  12. Mass Spectrometric Method for Analyzing Metabolites in Yeast with Single Cell Sensitivity

    NARCIS (Netherlands)

    Amantonico, Andrea; Oh, Joo Yeon; Sobek, Jens; Heinemann, Matthias; Zenobi, Renato

    2008-01-01

    Getting a look-in: An optimized MALDI-MS procedure has been developed to detect endogenous primary metabolites directly in the cell extract. A detection limit corresponding to metabolites from less than a single cell has been attained, opening the door to single-cell metabolomics by mass

  13. Hybrid recoil mass analyzer at IUAC – First results using gas-filled ...

    Indian Academy of Sciences (India)

    kinematics (to access heavy nuclei around 200 amu mass and beyond) and both ... totype each of RFQ and DTL are undergoing detailed tests for field ... magnet MD1 in gas-filled mode and is especially attractive in reactions induced by ... calculated using GIOS [11] ion-optical program to get the maximum count rate on.

  14. Volumetric vs Mass Velocity in Analyzing Convective-Diffusive Transport Processes in Liquids

    Science.gov (United States)

    Brenner, Howard

    2000-11-01

    Because mass rather than volume is preserved in fluid-mechanical problems involving density changes, a natural predilection exists for quantifying convective-diffusive transport phenomena in terms of a velocity field based upon mass, rather than volume. Indeed, in the classic BSL "Transport Phenomena" textbook, but a single reference exists even to the very concept of a volume velocity, and even then it is relegated to a homework assignment. However, especially when dealing with transport in fluids in which the mass density of the conserved property being transported (e.g., chemical species, internal energy, etc.) is independent of the prevailing pressure, as is largely true in the case of liquids, overwhelming advantages exist is preferring the volume velocity over the more ubiquitous and classical mass velocity. In a generalization of ideas pioneered by D. D. Joseph and co-workers, we outline the reasons for this volumetric velocity preference in a broad general context by identifying a large class of physical problems whose solutions are rendered more accessible by exploiting this unconventional velocity choice.

  15. Modified quadrupole mass analyzer RGA-100 for beam plasma research in forevacuum pressure range

    Energy Technology Data Exchange (ETDEWEB)

    Zolotukhin, D. B.; Tyunkov, A. V. [Tomsk State University of Control Systems and Radioelectronics, 40 Lenin Ave., Tomsk 634050 (Russian Federation); Yushkov, Yu. G., E-mail: yuyushkov@gmail.com [Tomsk State University of Control Systems and Radioelectronics, 40 Lenin Ave., Tomsk 634050 (Russian Federation); Tomsk Polytechnic University, 30 Lenin Ave., Tomsk 634050 (Russian Federation); Oks, E. M. [Tomsk State University of Control Systems and Radioelectronics, 40 Lenin Ave., Tomsk 634050 (Russian Federation); Institute of High Current Electronics SB RAS, 2/3, Akademichesky Ave., Tomsk 634055 (Russian Federation)

    2015-12-15

    The industrial quadrupole RGA-100 residual gas analyzer was modified for the research of electron beam-generated plasma at forevacuum pressure range. The standard ionizer of the RGA-100 was replaced by three electrode extracting unit. We made the optimization of operation parameters in order to provide the maximum values of measured currents of any ion species. The modified analyzer was successfully tested with beam plasma of argon, nitrogen, oxygen, and hydrocarbons.

  16. Analyzing the requirements for mass production of small wind turbine generators

    Science.gov (United States)

    Anuskiewicz, T.; Asmussen, J.; Frankenfield, O.

    Mass producibility of small wind turbine generators to give manufacturers design and cost data for profitable production operations is discussed. A 15 kW wind turbine generator for production in annual volumes from 1,000 to 50,000 units is discussed. Methodology to cost the systems effectively is explained. The process estimate sequence followed is outlined with emphasis on the process estimate sheets compiled for each component and subsystem. These data enabled analysts to develop cost breakdown profiles crucial in manufacturing decision-making. The appraisal also led to various design recommendations including replacement of aluminum towers with cost effective carbon steel towers. Extensive cost information is supplied in tables covering subassemblies, capital requirements, and levelized energy costs. The physical layout of the plant is depicted to guide manufacturers in taking advantage of the growing business opportunity now offered in conjunction with the national need for energy development.

  17. A Stable-Isotope Mass Spectrometry-Based Metabolic Footprinting Approach to Analyze Exudates from Phytoplankton

    Directory of Open Access Journals (Sweden)

    Mark R. Viant

    2013-10-01

    Full Text Available Phytoplankton exudates play an important role in pelagic ecology and biogeochemical cycles of elements. Exuded compounds fuel the microbial food web and often encompass bioactive secondary metabolites like sex pheromones, allelochemicals, antibiotics, or feeding attractants that mediate biological interactions. Despite this importance, little is known about the bioactive compounds present in phytoplankton exudates. We report a stable-isotope metabolic footprinting method to characterise exudates from aquatic autotrophs. Exudates from 13C-enriched alga were concentrated by solid phase extraction and analysed by high-resolution Fourier transform ion cyclotron resonance mass spectrometry. We used the harmful algal bloom forming dinoflagellate Alexandrium tamarense to prove the method. An algorithm was developed to automatically pinpoint just those metabolites with highly 13C-enriched isotope signatures, allowing us to discover algal exudates from the complex seawater background. The stable-isotope pattern (SIP of the detected metabolites then allowed for more accurate assignment to an empirical formula, a critical first step in their identification. This automated workflow provides an effective way to explore the chemical nature of the solutes exuded from phytoplankton cells and will facilitate the discovery of novel dissolved bioactive compounds.

  18. Following the Ions through a Mass Spectrometer with Atmospheric Pressure Interface: Simulation of Complete Ion Trajectories from Ion Source to Mass Analyzer.

    Science.gov (United States)

    Zhou, Xiaoyu; Ouyang, Zheng

    2016-07-19

    Ion trajectory simulation is an important and useful tool in instrumentation development for mass spectrometry. Accurate simulation of the ion motion through the mass spectrometer with atmospheric pressure ionization source has been extremely challenging, due to the complexity in gas hydrodynamic flow field across a wide pressure range as well as the computational burden. In this study, we developed a method of generating the gas flow field for an entire mass spectrometer with an atmospheric pressure interface. In combination with the electric force, for the first time simulation of ion trajectories from an atmospheric pressure ion source to a mass analyzer in vacuum has been enabled. A stage-by-stage ion repopulation method has also been implemented for the simulation, which helped to avoid an intolerable computational burden for simulations at high pressure regions while it allowed statistically meaningful results obtained for the mass analyzer. It has been demonstrated to be suitable to identify a joint point for combining the high and low pressure fields solved individually. Experimental characterization has also been done to validate the new method for simulation. Good agreement was obtained between simulated and experimental results for ion transfer though an atmospheric pressure interface with a curtain gas.

  19. Proof of Concept Coded Aperture Miniature Mass Spectrometer Using a Cycloidal Sector Mass Analyzer, a Carbon Nanotube (CNT) Field Emission Electron Ionization Source, and an Array Detector

    Science.gov (United States)

    Amsden, Jason J.; Herr, Philip J.; Landry, David M. W.; Kim, William; Vyas, Raul; Parker, Charles B.; Kirley, Matthew P.; Keil, Adam D.; Gilchrist, Kristin H.; Radauscher, Erich J.; Hall, Stephen D.; Carlson, James B.; Baldasaro, Nicholas; Stokes, David; Di Dona, Shane T.; Russell, Zachary E.; Grego, Sonia; Edwards, Steven J.; Sperline, Roger P.; Denton, M. Bonner; Stoner, Brian R.; Gehm, Michael E.; Glass, Jeffrey T.

    2018-02-01

    Despite many potential applications, miniature mass spectrometers have had limited adoption in the field due to the tradeoff between throughput and resolution that limits their performance relative to laboratory instruments. Recently, a solution to this tradeoff has been demonstrated by using spatially coded apertures in magnetic sector mass spectrometers, enabling throughput and signal-to-background improvements of greater than an order of magnitude with no loss of resolution. This paper describes a proof of concept demonstration of a cycloidal coded aperture miniature mass spectrometer (C-CAMMS) demonstrating use of spatially coded apertures in a cycloidal sector mass analyzer for the first time. C-CAMMS also incorporates a miniature carbon nanotube (CNT) field emission electron ionization source and a capacitive transimpedance amplifier (CTIA) ion array detector. Results confirm the cycloidal mass analyzer's compatibility with aperture coding. A >10× increase in throughput was achieved without loss of resolution compared with a single slit instrument. Several areas where additional improvement can be realized are identified.

  20. Study of the mass and energy resolution of the E parallel B charge exchange analyzer for TFTR

    International Nuclear Information System (INIS)

    Kaita, R.; Medley, S.S.

    1979-09-01

    The charge exchange diagnostic for TFTR requires simultaneous multispecie (H + , D + , γ + ) analysis of particles in the energy range of 0.5 - 150 keV. The analyzer design chosen to provide this capability employs a wide gap semi-circular region of superimposed parallel electric and magnetic fields to accomplish mass and energy resolution, respectively. Combined with a large area, multi-anode microchannel plate detector, this arrangement will enable the energy distributions of protons, deuterions, and tritons to be measured concurrently as a function of time during each discharge. A computer simulation program for calculating ion trajectories through the analyzer was written that includes a realistic model of the magnetic and electrostatic fringe fields. This report presents the results of a study of the proposed E parallel B analyzer, and it reveals that the fringe fields are not detrimental to the performance of the analyzer

  1. Evaluation of automated enzyme immunoassays for five anticonvulsants and theophylline adapted to a centrifugal analyzer.

    Science.gov (United States)

    Urquhart, N; Godolphin, W; Campbell, D J

    1979-05-01

    We report a clinical evaluation of the enzyme immunoassay (EMIT) performed with the GEMSAEC centrifugal analyzer as compared to gas-liquid and liquid chromatography for anticonvulsant drugs and theophylline, respectively. A good correlation was obtained for all drugs, although some difficulties were experienced with one lot of reagent for ethosuximide. The analyzer has an economic advantage if many samples are being analyzed for few drugs in each sample.

  2. Plain Language Summary: Evaluation of the Neck Mass in Adults.

    Science.gov (United States)

    Pynnonen, Melissa A; Colandrea, Maria; Finestone, Sandra A; O'Connor, Sarah S

    2017-09-01

    This plain language summary serves as an overview in explaining the evaluation of the neck mass in adults. The summary applies to patients aged ≥18 years and is based on the 2017 "Clinical Practice Guideline: Evaluation of the Neck Mass in Adults." The evidence-based guideline includes research to support more effective evaluation and diagnosis of the neck mass in adults. The guideline was developed as a quality improvement opportunity for evaluation of the neck mass by creating clear recommendations to use in medical practice.

  3. Crashworthiness evaluation of mass transit buses.

    Science.gov (United States)

    2008-11-01

    Mass transit bus systems are an integral part of the national transportation network, serving more than 20.6 billion passenger-miles per year with a relatively low fatality rate. Bus occupant injuries are evenly distributed among crashes on all sides...

  4. Rapid identification of pork for halal authentication using the electronic nose and gas chromatography mass spectrometer with headspace analyzer.

    Science.gov (United States)

    Nurjuliana, M; Che Man, Y B; Mat Hashim, D; Mohamed, A K S

    2011-08-01

    The volatile compounds of pork, other meats and meat products were studied using an electronic nose and gas chromatography mass spectrometer with headspace analyzer (GCMS-HS) for halal verification. The zNose™ was successfully employed for identification and differentiation of pork and pork sausages from beef, mutton and chicken meats and sausages which were achieved using a visual odor pattern called VaporPrint™, derived from the frequency of the surface acoustic wave (SAW) detector of the electronic nose. GCMS-HS was employed to separate and analyze the headspace gasses from samples into peaks corresponding to individual compounds for the purpose of identification. Principal component analysis (PCA) was applied for data interpretation. Analysis by PCA was able to cluster and discriminate pork from other types of meats and sausages. It was shown that PCA could provide a good separation of the samples with 67% of the total variance accounted by PC1. Copyright © 2011 Elsevier Ltd. All rights reserved.

  5. Radiologic evaluation of spinal epidural mass

    International Nuclear Information System (INIS)

    Lee, Ho Kyu; Lee, Moon Kyu; Chang, Kee Hyun

    1987-01-01

    It is often difficult to differentiate each pathologic entity among various spinal epidural masses on the radiologic basis. We retrospectively analysed radiologic findings of 67 cases of pathologically proven spinal epidural mass to find out any specific findings of each epidural mass. The results are as follows : 1. Of 67 cases, metastasis (16 cases), epidural abscess (15 cases), neurogenic tumor (16 cases) and meningioma (8 cases) are most common. The others consist of epidural angioma (3 cases), vertebral hemangioma (2 cases), chondrosarcoma (2 cases), fibrosarcoma (1 case), eosinophilic granuloma (1 case), lymphoma (1 case), lipoma (1 case) and lymphoid hyperplasia (1 case). 2. Destruction of the adjacent bone was commonly associated with the epidural mass in metastasis (75%) and epidural abscess (67%). It was also noted in 2 cases of chondrosarcoma, 1 fibrosarcoma and 1 eosinophilic granuloma. 3. Pressure erosion of adjacent bone was demonstrated in neurogenic tumor (75%) and meningioma (25%). 4. Narrowing of intervertebral space was seen in only 27% of epidural abscess. 5. The paraspinal tumor was associated in 67% of metastasis, 80% of epidural abscess, 75% of neurogenic tumor, 33% of meningioma. It was also seen in 2 cases of chondrosarcoma, 1 fibrosarcoma and 1 eosinophilic granuloma. 6. The intradural tumor was associated in 50% of neurogenic tumor and 67% of meningioma. 7. On axial CT image, most of the epidural mass shows eccentric location with displacing dural sac to the opposite side. The diseases that occasionally show encircling location are metastasis, epidural abscess, vertebral hemangioma, chondrosarcoma, eosinophilic granuloma, and lymphoma. Neurogenic tumor only shows multicentric location. 8. The disease extent more than height of one vertebral body was seen in 80% of epidural abscess, 58% of neurogenic tumor, 100% of epidural angioma. It was also seen in 2 cases of chondrosarcoma, 1 fibrosarcoma, 1 eosinophilic granuloma, 1 lymphoma, 1

  6. Analysis of corrosions-products in tissue samples near surgical implants by means of LAMMA (Laser Microprobe Mass Analyzer) and ICP-MS (Inductively Coupled Plasma Mass Spectrometer)

    International Nuclear Information System (INIS)

    Schlagenhaufen, C.

    1996-08-01

    In this work corrosion products of surgical implants in tissue samples were identified. For the characterization of the corrosion products the LAMMA 500 (Laser Microprobe Mass Analyzer) was used. Additional analysis were made with the ICP-MS (Inductively Coupled Plasma Mass Spectrometer) to determine the concentration of chromium, cobalt, nickel, and molybdenum in the tissues. In the first part several synthetic chromium- and molybdenum compounds were investigated with LAMMA. With the anionic mass spectra of the chromium-compounds it is possible to the oxidation state of chromium. The mass spectra of the synthetic compounds were used to identify, the compounds in the corrosion products. In the second part thin sections prepared from the tissue samples from the surrounding of the implants were analyzed. Several embedding and cutting methods were tested. Histological staining methods and LAMMA spectra were used to characterize the deposits in the tissue. Three different deposits were found in the tissue. In all tissues metal splinters from the implant were found. In most of the tissues iron-rich deposits were found, that were identified as iron-phosphate. As definitive corrosion products of the implant mixtures of chromium(III)phosphate, calcium molybdate, calcium phosphate and chromium(III) molybdate were identified. The ICP-MS results show in comparison to normal values, very high concentrations for chromium, nickel, cobalt and molybdenum. These results support the conclusions based on LAMMA results. The results of these investigations clearly indicate, that stainless steel implants, are not corrosion-resistant in the body. Relatively high amounts of the constituents, of the implant dissolved, and are deposited as solid compounds in the tissue next to the implant. (author)

  7. [Analyze prescription rules of Professor Jiang Liangduo treatment for abdominal mass based on traditional Chinese medicine inheritance platform].

    Science.gov (United States)

    Lian, Xiao-Xiao; Guo, Xiao-Xia

    2018-01-01

    To investigate the herbal prescription rules of Professor Jiang Liangduo in the treatment of abdominal mass based on the traditional Chinese medicine inheritance support system software (TCMISS) of version 2.5, find out new herbal formulas for the treatment of abdominal mass, and then provide new reference to its traditional Chinese medicine therapy. By the method of retrospective study, one hundred and thirty-two outpatient prescriptions of Professor Jiang for the treatment of abdominal mass were collected to establish a typical database with TCMISS. Four properties, five tastes, channel tropism, frequency count, Chinese herbal prescriptions rules and the new prescriptions were analyzed so as to dig out the prescription rules. There were 57 herbs with a frequency>=15, and then 91 core combinations of 2-5 herbs were evolved and 9 new prescriptions were created. It was found out that these drugs mainly had the effects of liver nourishing and soothing, soft-moist and dredging-tonifying, supporting right and dispeling evil, cooperating with the method of calming the liver and resolving hard lump according to the actual situation. It reflected the thought of treatment based on syndrome differentiation in TCM, and provided a new reference for its clinical treatment and research. Copyright© by the Chinese Pharmaceutical Association.

  8. Feasibility evaluation of a neutron grating interferometer with an analyzer grating based on a structured scintillator

    Science.gov (United States)

    Kim, Youngju; Kim, Jongyul; Kim, Daeseung; Hussey, Daniel. S.; Lee, Seung Wook

    2018-03-01

    We introduce an analyzer grating based on a structured scintillator fabricated by a gadolinium oxysulfide powder filling method for a symmetric Talbot-Lau neutron grating interferometer. This is an alternative way to analyze the Talbot self-image of a grating interferometer without using an absorption grating to block neutrons. Since the structured scintillator analyzer grating itself generates the signal for neutron detection, we do not need an additional scintillator screen as an absorption analyzer grating. We have developed and tested an analyzer grating based on a structured scintillator in our symmetric Talbot-Lau neutron grating interferometer to produce high fidelity absorption, differential phase, and dark-field contrast images. The acquired images have been compared to results of a grating interferometer utilizing a typical absorption analyzer grating with two commercial scintillation screens. The analyzer grating based on the structured scintillator enhances interference fringe visibility and shows a great potential for economical fabrication, compact system design, and so on. We report the performance of the analyzer grating based on a structured scintillator and evaluate its feasibility for the neutron grating interferometer.

  9. History and status of atomic mass measurement and evaluation

    International Nuclear Information System (INIS)

    Huang Wenxue; Zhu Zhichao; Wang Meng; Wang Yue; Tian Yulin; Xu Hushan; Xiao Guoqing

    2010-01-01

    Mass is one of the most fundamental properties that can be obtained about an atomic nucleus. High-accuracy mass values for atoms let us study the atomic and nuclear binding energies that represent the sum of all the atomic and nucleonic interactions. Looking on the history of nuclear masses, it can be found that it is almost as old as that of nuclear physics itself. The experimental methods for masses and the relevant outcomes are so rich that the evaluation is needed to check the consistency among the various results and obtain more reliable data. The atomic mass evaluation is a considerate and complicated process. This paper introduces briefly the history and status of atomic mass measurement and evaluation. (authors)

  10. A System Evaluation Theory Analyzing Value and Results Chain for Institutional Accreditation in Oman

    Science.gov (United States)

    Paquibut, Rene Ymbong

    2017-01-01

    Purpose: This paper aims to apply the system evaluation theory (SET) to analyze the institutional quality standards of Oman Academic Accreditation Authority using the results chain and value chain tools. Design/methodology/approach: In systems thinking, the institutional standards are connected as input, process, output and feedback and leads to…

  11. Laboratory evaluation of the Coasys® Plus C coagulation analyzer

    NARCIS (Netherlands)

    de Bie, Prim; Schornagel, Willem J.; van den Dool, Erik-Jan; Bakker, Bianca; van Dam, Willem; Heckman, Marion; Ağar, Cetin; Sturk, Auguste; Stroobants, An K.

    2013-01-01

    The Coasys® Plus C (Behnk Elektronik, distributed by Roche Diagnostics) is a coagulation analyzer for small to midsize clinical chemistry laboratories. We performed a laboratory evaluation. After a familiarization period the dead volume, carry-over, capacity, within-assay reproducibility and

  12. Evaluation of the i-STAT point-of-care analyzer in critically ill adult patients.

    NARCIS (Netherlands)

    Steinfelder-Visscher, J.; Teerenstra, S.; Klein Gunnewiek, J.M.T.; Weerwind, P.W.

    2008-01-01

    Point-of-care analyzers may benefit therapeutic decision making by reducing turn-around-time for samples. This is especially true when biochemical parameters exceed the clinical reference range, in which acute and effective treatment is essential. We therefore evaluated the analytical performance of

  13. The Orbitrap mass analyzer as a space instrument for the understanding of prebiotic chemistry in the Solar System

    Science.gov (United States)

    Vuitton, Véronique; Briois, Christelle; Makarov, Alexander

    Over the past decade, it has become apparent that organic molecules are widespread in our Solar System and beyond. The better understand of the prebiotic chemistry leading to their formation is a primary objective of many ongoing space missions. Cassini-Huygens revealed the existence of very large molecular structures in Titan's atmosphere as well as on its surface, in the form of dune deposits, but their exact nature remains elusive. One key science goal of the Mars Science Laboratory Curiosity rover is to assess the presence of organics on the red planet. Rosetta will characterize the elemental and isotopic composition of the gas and dust ejected from comet Churyumov-Gerasimenko, while amino acids have been detected in meteorites. This search for complex organics relies heavily on mass spectrometry, which has the remarkable ability to analyze and quantify species from almost any type of sample (provided that the appropriate sampling and ionizing method is used). Because of the harsh constraints of the spatial environment, the mass resolution of the spectrometers onboard current space probes is quite limited compared to laboratory instruments, leading to significant limitations in the scientific return of the data collected. Therefore, future in situ solar system exploration missions would significantly benefit from instruments relying on High Resolution Mass Spectrometry (HRMS). Since 2009, 5 French laboratories (LPC2E, IPAG, LATMOS, LISA, CSNSM) involved in the chemical investigation of solar system bodies form a Consortium to develop HRMS for future space exploration, based on the use of the Orbitrap technology (C. Briois et al., 2014, to be submitted). The work is undertaken in close collaboration with the Thermo Fisher Scientific Company, which commercializes Orbitrap based laboratory instruments. The Orbitrap is an electrostatic mass analyzer, it is compact, lightweight, and can reach a good sensitivity and dynamic range. A prototype is under development at

  14. Isotopic abundance analysis of carbon, nitrogen and sulfur with a combined elemental analyzer-mass spectrometer system

    International Nuclear Information System (INIS)

    Pichlmayer, F.; Blochberger, K.

    1988-01-01

    Stable isotope ratio measurements of carbon, nitrogen and sulfur are of growing interest as analytical tool in many fields of research, but applications were somewhat hindered in the past by the fact that cumbersome sample preparation was necessary. A method has therefore been developed, consisting in essential of coupling an elemental analyzer with an isotope mass spectrometer, enabling fast and reliable conversion of C-, N- and S-compounds in any solid or liquid sample into the measuring gases carbon dioxide, nitrogen and sulfur dioxide for on-line isotopic analysis. The experimental set-up and the main characteristics are described in short and examples of application in environmental research, food analysis and clinical diagnosis are given. (orig.)

  15. Resonantly-enhanced two-photon ionization and mass-analyzed threshold ionization (MATI) spectroscopy of 2-hydroxypyridine

    CERN Document Server

    Lee, D H; Choi, K W; Choi, Y S; Kim, S K

    2002-01-01

    Mass-analyzed threshold ionization (MATI) spectra of 2-hydroxypyridines existing as lactims (2-pyridionl) in a molecular beam are obtained via (1+1') two-photon process to give accurate ionization energies of 8.9344 +- 0.0005 and 8.9284 +- 0.0005 eV for 2-pyridinol (2Py-OH) and its deuterated analogue (2Py-OD), respectively. Resonantly-enhanced two-photon ionization spectra of these compounds are also presented to give vibrational structures of their S sub 1 states. Vibrational frequencies of 2Py-OH and 2Py-OD in ionic ground states are accurately determined from MATI spectra taken via various S sub 1 intermediate states, and associated vibrational modes are assigned with the aid of ab initio calculations.

  16. COINTOF mass spectrometry: design of a time-of-flight analyzer and development of the analysis method

    International Nuclear Information System (INIS)

    Teyssier, C.

    2012-01-01

    DIAM (Device for the irradiation of molecular clusters) is a newly designed experimental setup to investigate processes resulting from the irradiation of molecular nano-systems by 20-150 keV protons. One of its specificities relies on the original technique of mass spectrometry named COINTOF (Correlated Ion and Neutral Time Of Flight) consisting in correlated measurements of the time of flight of charged and neutral fragments produced by the dissociation of a single molecular ion parent. A strategy of treatment and analysis of the detection signals was developed to distinguish two fragments close in time ( 3 O + and two water molecules. The distribution of the time of flight difference between the two neutral fragments is measured providing an estimate of the kinetic energy release of a few eV. In parallel, a second time-of-flight mass spectrometer was designed. It associates a linear time-of-flight and an orthogonal time-of-flight and integrates position detectors (delay line anode). Simulations demonstrate the potentials of the new analyzer. Finally, research works were led at the laboratory R.-J. A. Levesque (Universite de Montreal) on the imaging capabilities of the multi-pixel detectors of the MPX-ATLAS collaboration. (author)

  17. How accurate is ultrasound in evaluating palpable breast masses ...

    African Journals Online (AJOL)

    Methods: Eighty palpable breast masses were evaluated at ultrasound and information about the characteristic features of the masses was recorded. An impression about the diagnosis was made and results were correlated with histology findings. Results: The overall sensitivity of ultrasound in detecting breast lumps was ...

  18. A Low Cost Shading Analyzer and Site Evaluator Design to Determine Solar Power System Installation Area

    Directory of Open Access Journals (Sweden)

    Selami Kesler

    2015-01-01

    Full Text Available Shading analyzer systems are necessary for selecting the most suitable installation site to sustain enough solar power. Afterwards, changes in solar data throughout the year must be evaluated along with the identification of obstructions surrounding the installation site in order to analyze shading effects on productivity of the solar power system. In this study, the shading analysis tools are introduced briefly, and a new and different device is developed and explained to analyze shading effect of the environmental obstruction on the site on which the solar power system will be established. Thus, exposure duration of the PV panels to the sunlight can be measured effectively. The device is explained with an application on the installation area selected as a pilot site, Denizli, in Turkey.

  19. Development and Evaluation of an Adolescents' Depression Ontology for Analyzing Social Data.

    Science.gov (United States)

    Jung, Hyesil; Park, Hyeoun-Ae; Song, Tae-Min

    2016-01-01

    This study aims to develop and evaluate an ontology for adolescents' depression to be used for collecting and analyzing social data. The ontology was developed according to the 'ontology development 101' methodology. Concepts were extracted from clinical practice guidelines and related literatures. The ontology is composed of five sub-ontologies which represent risk factors, sign and symptoms, measurement, diagnostic result and management care. The ontology was evaluated in four different ways: First, we examined the frequency of ontology concept appeared in social data; Second, the content coverage of ontology was evaluated by comparing ontology concepts with concepts extracted from the youth depression counseling records; Third, the structural and representational layer of the ontology were evaluated by 5 ontology and psychiatric nursing experts; Fourth, the scope of the ontology was examined by answering 59 competency questions. The ontology was improved by adding new concepts and synonyms and revising the level of structure.

  20. Evaluation of the i-STAT point-of-care analyzer in critically ill adult patients.

    Science.gov (United States)

    Steinfelder-Visscher, Jacoline; Teerenstra, Steven; Gunnewiek, Jacqueline M T Klein; Weerwind, Patrick W

    2008-03-01

    Point-of-care analyzers may benefit therapeutic decision making by reducing turn-around-time for samples. This is especially true when biochemical parameters exceed the clinical reference range, in which acute and effective treatment is essential. We therefore evaluated the analytical performance of the i-STAT point-of-care analyzer in two critically ill adult patient populations. During a 3-month period, 48 blood samples from patients undergoing cardiac surgery with cardiopulmonary bypass (CPB) and 42 blood samples from non-cardiac patients who needed intensive care treatment were analyzed on both the i-STAT analyzer (CPB and non-CPB mode, respectively) and our laboratory analyzers (RapidLab 865/Sysmex XE-2100 instrument). The agreement analysis for quantitative data was used to compare i-STAT to RapidLab for blood gas/electrolytes and for hematocrit with the Sysmex instrument. Point-of-care electrolytes and blood gases had constant deviation, except for pH, pO2, and hematocrit. A clear linear trend in deviation of i-STAT from RapidLab was noticed for pH during CPB (r = 0.32, p = .03) and for pO2 > 10 kPa during CPB (r = -0.59, p pO2 pO2 pO2 range (10.6 pO2 range below 25% (n = 11) using the i-STAT. The i-STAT analyzer is suitable for point-of-care testing of electrolytes and blood gases in critically ill patients, except for high pO2. However, the discrepancy in hematocrit bias shows that accuracy established in one patient population cannot be automatically extrapolated to other patient populations, thus stressing the need for separate evaluation.

  1. Blood gas analyzer utility in evaluating oxygen kinetics of the aqueous humor

    Directory of Open Access Journals (Sweden)

    Ismail Ersan

    2015-04-01

    Full Text Available Purpose: To measure the partial pressure of oxygen (PO2 and carbon dioxide (PCO2 and the pH of aqueous humor (AH and arterial blood samples from rabbits using a blood gas analyzer. Methods: Twenty New Zealand rabbits were anesthetized intramuscularly with ketamine and xylazine and were then allowed to breathe room air. Using a gas blood analyzer, arterial blood and AH samples were analyzed for PO2, PCO2, and pH. Results: The mean arterial blood pressure was 87.14 ± 15.0 mmHg. The mean blood and AH PO2 were 95.18 ± 11.76 mmHg and 88.83 ± 9.92 mmHg, the mean blood and AH PCO2 were 25.86 ± 5.46 mmHg and 29.50 ± 5.36 mmHg, and the mean blood and AH pH were 7.38 ± 0.06 and 7.33 ± 0.09, respectively. Conclusion: Conclusions: The blood gas analyzer was easily employed to evaluate the aqueous humor in rabbits. When comparing the results of studies evaluating aqueous PO2, care should be taken to determine the methods used in these studies.

  2. Evaluation of Portable Multi-Gas Analyzers for use by Safety Personnel

    Science.gov (United States)

    Lueck, D. E.; Meneghelli, B. J.; Bardel, D. N.

    1998-01-01

    During confined space entry operations as well as Shuttle-safing operations, United Space Alliance (USA)/National Aeronautics and Space Administration (NASA) safety personnel use a variety of portable instrumentation to monitor for hazardous levels of compounds such as nitrogen dioxide (N%), monomethylhydrazine (NMM), FREON 21, ammonia (NH3), oxygen (O2), and combustibles (as hydrogen (H2)). Except for O2 and H2, each compound is monitored using a single analyzer. In many cases these analyzers are 5 to 10 years old and require frequent maintenance. In addition, they are cumbersome to carry and tend to make the job of personnel monitoring physically taxing. As part of an effort to upgrade the sensor technology background information was requested from a total of 27 manufacturers of portable multi-gas instruments. A set of criteria was established to determine which vendors would be selected for laboratory evaluation. These criteria were based on requests made by USA/NASA Safety personnel in order to meet requirements within their respective areas for confined-space and Shuttle-safing operations. Each of the 27 manufacturers of multi-gas analyzers was sent a copy of the criteria and asked to fill in the appropriate information pertaining to their instrumentation. Based on the results of the sensor criteria worksheets, a total of 9 vendors out of 27 surveyed manufacturers were chosen for evaluation. Each vendor included in the final evaluation process was requested to configure each of two analyzers with NO2, NH3, O2, and combustible sensors. A set of lab tests was designed in order to determine which of the multi-gas instruments under evaluation was best suited for use in both shuttle and confined space operations. These tests included linearity/repeatability, zero/span drift response/recovery, humidity, interference, and maintenance. At the conclusion of lab testing three vendors were selected for additional field testing. Based on the results of both the lab and

  3. PALOMA : an isotope analyzer using static mass spectrometry, coupled with cryogenic and chemical trapping, for the MSL mission to Mars

    Science.gov (United States)

    Chassefiere, E.; Jambon, A.; Berthelier, J.-J.; Goulpeau, G.; Leblanc, F.; Montmessin, F.; Sarda, P.; Agrinier, P.; Fouchet, T.; Waite, H.

    The technique of GCMS analysis has to be completed by static mass spectrometry for precise in-situ measurements of the isotopic composition of planetary atmospheres (noble gases, stable isotopes), and volatile outgassed products from solid sample pyrolysis. Static mass spectrometry, coupled with gas separation by cryo-separation and gettering, is commonly used in the laboratory to study volatiles extracted from terrestrial and meteoritic samples. Such an instrument (PALOMA) is presently developed in our laboratories, and it will be coupled with a Pyr-GCMS analyzer (MACE), built by a US consortium of science laboratories and industrials (University of Michigan, Southwest Research Institute, JPL, Ball Aerospace). The MACE/PALOMA experiment will be proposed on the NASA Mars Science Laboratory mission, planned to be launched in 2009. The scientific objectives of PALOMA, coupled with MACE, may be listed as follows : (i) search for isotopic signatures of past life in atmosphere, rock, dust and ice samples, with emphasis on carbon, nitrogen and hydrogen; (ii) accurately measure isotopic composition of atmospheric noble gases, and stable isotopes, in order to better constrain past escape, surface interaction, outgassing history and climate evolution; (iii) precisely measure diurnal/ seasonal variations of isotopic ratios of H2O, CO2, and N2, for improving our understanding of present and past climate, and of the role of water cycle. Main measurement objectives are : (i) C, H, O, N isotopic composition in both organic evolved samples (provided by MACE pyrolysis system) and atmosphere with high accuracy (a few per mil at 1-s level); (ii) noble gas (He, Ne, Ar, Kr, Xe) and stable (C, H, O, N) isotope composition in atmosphere with high accuracy (a few per mil at 1-s level); (iii) molecular and isotopic composition of inorganic evolved samples (salts, hydrates, nitrates, {ldots}), including ices; (iv) diurnal and seasonal monitoring of D/H in water vapor, and water ice.

  4. Evaluation of axial pile bearing capacity based on pile driving analyzer (PDA) test using Neural Network

    Science.gov (United States)

    Maizir, H.; Suryanita, R.

    2018-01-01

    A few decades, many methods have been developed to predict and evaluate the bearing capacity of driven piles. The problem of the predicting and assessing the bearing capacity of the pile is very complicated and not yet established, different soil testing and evaluation produce a widely different solution. However, the most important thing is to determine methods used to predict and evaluate the bearing capacity of the pile to the required degree of accuracy and consistency value. Accurate prediction and evaluation of axial bearing capacity depend on some variables, such as the type of soil, diameter, and length of pile, etc. The aims of the study of Artificial Neural Networks (ANNs) are utilized to obtain more accurate and consistent axial bearing capacity of a driven pile. ANNs can be described as mapping an input to the target output data. The method using the ANN model developed to predict and evaluate the axial bearing capacity of the pile based on the pile driving analyzer (PDA) test data for more than 200 selected data. The results of the predictions obtained by the ANN model and the PDA test were then compared. This research as the neural network models give a right prediction and evaluation of the axial bearing capacity of piles using neural networks.

  5. Evaluation of corneal biomechanics in patients with keratectasia following LASIK using dynamic Scheimpflug analyzer.

    Science.gov (United States)

    Ueki, Ryotaro; Maeda, Naoyuki; Fuchihata, Mutsumi; Asai, Tomoko; Koh, Shizuka; Fujimoto, Hisataka; Uematsu, Masafumi; Nishida, Kohji

    2018-04-26

    To investigate the corneal biomechanics in eyes with keratectasia following LASIK using a dynamic Scheimpflug analyzer. Case-Control study. The subjects in the study included 12 eyes with keratectasia after LASIK (KE), 24 eyes with keratoconus (KC), 17 eyes without keratectasia after LASIK (LASIK), and 34 eyes with normal corneas (Normal). Corneal biomechanics of the four groups were evaluated using a dynamic Scheimpflug analyzer. Compared with Normal (7.06 ± 0.54), the radius at the highest concavity (radius, mm) of LASIK (5.96 ± 0.76), KE (4.93 ± 0.61) and KC (5.39 ± 1.02) were significantly small. The Deflection Amplitude (HCDLA, mm) of Normal (0.94 ± 0.07) was significantly lower than those of KE (1.11 ± 0.10) and KC (1.06 ± 0.16), and was not significantly different from that of LASIK (0.98 ± 0.07). There were significant differences between LASIK and KE in radius and HCDLA (P biomechanical features evaluated using the dynamic Scheimpflug analyzer suggest that biomechanical properties in eyes with keratectasia, keratoconus, and LASIK are different from those of normal eyes. Although the biomechanics in eyes with keratectasia differs from that in eyes with LASIK, it is similar to that in eyes with keratoconus.

  6. A communicational framework for evaluating interaction with IT by analyzing user-reception of electronic texts

    DEFF Research Database (Denmark)

    Wentzer, Helle

    2006-01-01

    Interpreting IT as a medium for continuous communication across time and place of the communicators offers a way of analyzing the effect of IT in concrete practices. The users’ readings determine the actual communication with IT. A poetics of how meaning is translated from one person to another...... through semiotic texts is presented, termed the poetics of the e-text. The poetics of the e-text offers a meta-communicational framework for identifying user constraints in the possibilities of interacting with the system. Identifying communicational problems with ICT-mediated interactions again offer...... grounds for redesigning and re-author the e-text. The poetics of the e-text are subsequently applied as a method of analyzing user-reception and evaluating the interaction with ICT. Examples are given from user-receptions of collaborating with ICT in home care, Denmark....

  7. Ages of Young Star Clusters, Massive Blue Stragglers, and the Upper Mass Limit of Stars: Analyzing Age-dependent Stellar Mass Functions

    NARCIS (Netherlands)

    Schneider, F.R.N.; Izzard, R.G.; de Mink, S.E.; Langer, N.; Stolte, A.; de Koter, A.; Gvaramadze, V.V.; Huβman, B.; Liermann, A.; Sana, H.

    2014-01-01

    Massive stars rapidly change their masses through strong stellar winds and mass transfer in binary systems. The latter aspect is important for populations of massive stars as more than 70% of all O stars are expected to interact with a binary companion during their lifetime. We show that such mass

  8. Development and evaluation of a workpiece temperature analyzer for industrial furnaces

    Energy Technology Data Exchange (ETDEWEB)

    1990-05-01

    An instrument capable of measuring the bulk temperature of a workpiece while it is being heated could have a variety of applications. If such an instrument were reasonably priced, it would have a tremendous impact upon national energy usage. The Department of Energy has realized the importance of this type of instrument and has sponsored three concurrent programs to evaluate three different technologies for this type of instrument. In one of these programs, Surface Combustion is the prime contractor to develop a pulsed laser, polarizing interferometer based sensor to be used as a workpiece temperature analyzer (WPTA). The overall goal of the program is to develop a workpiece temperature analyzer for industrial furnaces to significantly improve product quality, productivity and energy efficiency. The workpiece temperature analyzer concept in this program uses a pulsed laser polarizing interferometer (PLPI) for measuring sound velocity through a workpiece. This type of instrument has a high resolution and could detect surface motion of as small as 10 picometer. The sound velocity measurement can be converted to an average workpiece temperature through a mathematical equation programmed into the microprocessor used for control. 76 refs., 12 figs., 14 tabs.

  9. Evaluation of corneal biomechanical properties following penetrating keratoplasty using ocular response analyzer

    Directory of Open Access Journals (Sweden)

    Vanathi Murugesan

    2014-01-01

    Full Text Available Purpose: To evaluate corneal biomechanical properties in eyes that has undergone penetrating keratoplasty (PK. Materials and Methods: Retrospective observational study in a tertiary care centre. Data recorded included ocular response analyzer (ORA values of normal and post-keratoplasty eyes [corneal hysteresis (CH, corneal resistance factor (CRF, Goldmann-correlated intraocular pressure (IOPg, and cornea-compensated intraocular pressure (IOPcc], corneal topography, and central corneal thickness (CCT. Wilcoxon signed rank test was used to analyze the difference in ORA parameter between post-PK eyes and normal eyes. Correlation between parameters was evaluated with Spearman′s rho correlation. Results: The ORA study of 100 eyes of 50 normal subjects and 54 post-keratoplasty eyes of 51 patients showed CH of 8.340 ± 1.85 and 9.923 ± 1.558, CRF of 8.846 ± 2.39 and 9.577 ± 1.631 in post-PK eyes and normal eyes, respectively. CH and CRF did not correlate with post-keratoplasty astigmatism (P = 0.311 and 0.276, respectively while a significant correlation was observed with IOPg (P = 0.004 and IOPcc (P < 0.001. Conclusion: Biomechanical profiles were significantly decreased in post-keratoplasty eyes with significant correlation with higher IOP as compared with that in normal eyes.

  10. Evaluation of the DCA Vantage analyzer for HbA 1c assay.

    Science.gov (United States)

    Szymezak, Jean; Leroy, Nathalie; Lavalard, Emmanuelle; Gillery, Philippe

    2008-01-01

    Measurement of HbA 1c is key in monitoring diabetic patients in both laboratories and clinical units, where HbA 1c results are used as part of patient education. We have evaluated the DCA Vantage, a new device for immunological assay of HbA 1c. HbA 1c results obtained were evaluated in terms of precision, linearity, specificity and practicability, and were compared with results obtained by a Variant II HPLC method. The method exhibited intra- and inter-assay coefficients of variation lower than 2.6% and 4.0%, respectively, and good correlation with the comparison HPLC method (r2=0.9776). No interference was noted in the presence of labile HbA 1c or carbamylated hemoglobin. The new device exhibited improved practicability characteristics and allowed better sample identification, better management of quality control routines and greater connectivity possibilities compared to the previous DCA 2000 analyzer. This new analyzer exhibited analytical and practical characteristics very suitable for HbA 1c assay for laboratory or point-of-care use according to good laboratory practice.

  11. One-photon mass-analyzed threshold ionization (MATI) spectroscopy of pyridine: Determination of accurate ionization energy and cationic structure

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yu Ran; Kang, Do Won; Kim, Hong Lae, E-mail: chkwon@kangwon.ac.kr, E-mail: hlkim@kangwon.ac.kr; Kwon, Chan Ho, E-mail: chkwon@kangwon.ac.kr, E-mail: hlkim@kangwon.ac.kr [Department of Chemistry and Institute for Molecular Science and Fusion Technology, College of Natural Sciences, Kangwon National University, Chuncheon 200-701 (Korea, Republic of)

    2014-11-07

    Ionization energies and cationic structures of pyridine were intensively investigated utilizing one-photon mass-analyzed threshold ionization (MATI) spectroscopy with vacuum ultraviolet radiation generated by four-wave difference frequency mixing in Kr. The present one-photon high-resolution MATI spectrum of pyridine demonstrated a much finer and richer vibrational structure than that of the previously reported two-photon MATI spectrum. From the MATI spectrum and photoionization efficiency curve, the accurate ionization energy of the ionic ground state of pyridine was confidently determined to be 73 570 ± 6 cm{sup −1} (9.1215 ± 0.0007 eV). The observed spectrum was almost completely assigned by utilizing Franck-Condon factors and vibrational frequencies calculated through adjustments of the geometrical parameters of cationic pyridine at the B3LYP/cc-pVTZ level. A unique feature unveiled through rigorous analysis was the prominent progression of the 10 vibrational mode, which corresponds to in-plane ring bending, and the combination of other totally symmetric fundamentals with the ring bending overtones, which contribute to the geometrical change upon ionization. Notably, the remaining peaks originate from the upper electronic state ({sup 2}A{sub 2}), as predicted by high-resolution photoelectron spectroscopy studies and symmetry-adapted cluster configuration interaction calculations. Based on the quantitatively good agreement between the experimental and calculated results, it was concluded that upon ionization the pyridine cation in the ground electronic state should have a planar structure of C{sub 2v} symmetry through the C-N axis.

  12. Epsilon-Q: An Automated Analyzer Interface for Mass Spectral Library Search and Label-Free Protein Quantification.

    Science.gov (United States)

    Cho, Jin-Young; Lee, Hyoung-Joo; Jeong, Seul-Ki; Paik, Young-Ki

    2017-12-01

    Mass spectrometry (MS) is a widely used proteome analysis tool for biomedical science. In an MS-based bottom-up proteomic approach to protein identification, sequence database (DB) searching has been routinely used because of its simplicity and convenience. However, searching a sequence DB with multiple variable modification options can increase processing time, false-positive errors in large and complicated MS data sets. Spectral library searching is an alternative solution, avoiding the limitations of sequence DB searching and allowing the detection of more peptides with high sensitivity. Unfortunately, this technique has less proteome coverage, resulting in limitations in the detection of novel and whole peptide sequences in biological samples. To solve these problems, we previously developed the "Combo-Spec Search" method, which uses manually multiple references and simulated spectral library searching to analyze whole proteomes in a biological sample. In this study, we have developed a new analytical interface tool called "Epsilon-Q" to enhance the functions of both the Combo-Spec Search method and label-free protein quantification. Epsilon-Q performs automatically multiple spectral library searching, class-specific false-discovery rate control, and result integration. It has a user-friendly graphical interface and demonstrates good performance in identifying and quantifying proteins by supporting standard MS data formats and spectrum-to-spectrum matching powered by SpectraST. Furthermore, when the Epsilon-Q interface is combined with the Combo-Spec search method, called the Epsilon-Q system, it shows a synergistic function by outperforming other sequence DB search engines for identifying and quantifying low-abundance proteins in biological samples. The Epsilon-Q system can be a versatile tool for comparative proteome analysis based on multiple spectral libraries and label-free quantification.

  13. Performance evaluation of the Sysmex® XE-2100D automated hematology analyzer

    Directory of Open Access Journals (Sweden)

    Tavany Elisa Santos Maciel

    2014-02-01

    Full Text Available Introduction: The Sysmex® XE-2100D is a multiparameter hematology analyzer designed for hematology testing in samples with ethylenediamine tetraacetic acid (EDTA. Objectives: Considering the importance of this hematology analyzer for clinical and laboratory practice, the objective of this study was to evaluate its analytical performance, comparing the obtained results with quality specifications described in literature. Material and method: In the evaluation of analytical performance, according to recommendations of the document H26-A2 of the Clinical and Laboratory Standards Institute (CLSI, intra-run imprecision, inter-run imprecision, linearity, carryover, autosampler evaluation, clinical sensitivity of the atypical lymphocytes flag (n = 400 samples were included, as well as the comparison between automated and manual leukocyte differential count (n = 400 samples, based on an adaptation of the document H20-A2 of CLSI. Results: Repeatability, reproducibility, linearity and carryover were satisfactory according to the manufacturer's specifications. The clinical sensitivity of the atypical lymphocytes flag showed efficiency, sensitivity and specificity of 92.5%, 65.2% and 94.1% respectively. The correlation coefficients between the automated and manual differential counts of neutrophils, lymphocytes, monocytes, eosinophils and basophils were 0.991, 0.99, 0.872, 0.974 and 0.557, respectively. Conclusions: The results were in accordance with quality specifications described in literature, indicating reliability in Sysmex® XE-2100D. This fact ensures certainty to both laboratory professionals and medical staff. We conclude that the Sysmex® XE-2100D showed excellent analytical performance, and is useful to provide reliable hematology data.

  14. Evaluation of incompressible hydrodynamic mass methods in reactor applications

    International Nuclear Information System (INIS)

    Takeuchi, K.

    1981-01-01

    The hydrodynamic (or virtual) mass approach is evaluated by comparison of structural responses computed by the hydrodynamic mass method with those computed by MULTIFLEX code for a fluid/structure interaction problem with fluid compression effects taken into account. A sample problem used in that evaluation is a simplified 1-D PWR model which is first subjected to a LOCA type transient. The time history of structural displacement computed with the hydrodynamic mass approach is compared with MULTIFLEX results. The frequencies of structural oscillation of these two computations agree. The amplitudes disagree by more than 50%, which is attributed to the effect of fluid compressibility. For the seismic study, sinusoidal forces are applied to the floor at the vessel support. The system responses are expressed by the response functions or the maximum values of the barrel/vessel relative displacements as the applied frequency is varied. The response functions are computed by the hydrodynamic mass method and by MULTIFLEX for evaluation of the virtual mass method. For the pump pulsation study, sinusoidal pressure oscillations are applied at the pump outlet and the response functions are computed as above. 12 refs

  15. Symbolic Evaluation Graphs and Term Rewriting — A General Methodology for Analyzing Logic Programs

    DEFF Research Database (Denmark)

    Giesl, J.; Ströder, T.; Schneider-Kamp, P.

    2013-01-01

    There exist many powerful techniques to analyze termination and complexity of term rewrite systems (TRSs). Our goal is to use these techniques for the analysis of other programming languages as well. For instance, approaches to prove termination of definite logic programs by a transformation...... to TRSs have been studied for decades. However, a challenge is to handle languages with more complex evaluation strategies (such as Prolog, where predicates like the cut influence the control flow). We present a general methodology for the analysis of such programs. Here, the logic program is first...... information on the termination or complexity of the original logic program. More information can be found in the full paper [1]. © 2013 Springer-Verlag....

  16. Development and evaluation of porcine cysticercosis QuickELISA in Triturus EIA analyzer.

    Science.gov (United States)

    Handali, Sukwan; Pattabhi, Sowmya; Lee, Yeuk-Mui; Silva-Ibanez, Maria; Kovalenko, Victor A; Levin, Andrew E; Gonzalez, Armando E; Roberts, Jacquelin M; Garcia, Hector H; Gilman, Robert H; Hancock, Kathy; Tsang, Victor C W

    2010-01-01

    We evaluated three diagnostic antigens (recombinant GP50, recombinant T24H, and synthetic Ts18var1) for cysticercosis and found that all three performed well in detecting cysticercosis in humans and pigs in several assay formats. These antigens were adapted to a new antibody detection format (QuickELISA). With one single incubation step which involves all reactants except the enzyme substrate, the QuickELISA is particularly suited for automation. We formatted the QuickELISA for the Triturus EIA analyzer for testing large numbers of samples. We found that in QuickELISA formats rGP50 and rT24H have better sensitivity and specificity than sTs18var1 for detecting porcine cysticercosis.

  17. Clinical Practice Guideline: Evaluation of the Neck Mass in Adults.

    Science.gov (United States)

    Pynnonen, Melissa A; Gillespie, M Boyd; Roman, Benjamin; Rosenfeld, Richard M; Tunkel, David E; Bontempo, Laura; Brook, Itzhak; Chick, Davoren Ann; Colandrea, Maria; Finestone, Sandra A; Fowler, Jason C; Griffith, Christopher C; Henson, Zeb; Levine, Corinna; Mehta, Vikas; Salama, Andrew; Scharpf, Joseph; Shatzkes, Deborah R; Stern, Wendy B; Youngerman, Jay S; Corrigan, Maureen D

    2017-09-01

    Objective Neck masses are common in adults, but often the underlying etiology is not easily identifiable. While infections cause most of the neck masses in children, most persistent neck masses in adults are neoplasms. Malignant neoplasms far exceed any other etiology of adult neck mass. Importantly, an asymptomatic neck mass may be the initial or only clinically apparent manifestation of head and neck cancer, such as squamous cell carcinoma (HNSCC), lymphoma, thyroid, or salivary gland cancer. Evidence suggests that a neck mass in the adult patient should be considered malignant until proven otherwise. Timely diagnosis of a neck mass due to metastatic HNSCC is paramount because delayed diagnosis directly affects tumor stage and worsens prognosis. Unfortunately, despite substantial advances in testing modalities over the last few decades, diagnostic delays are common. Currently, there is only 1 evidence-based clinical practice guideline to assist clinicians in evaluating an adult with a neck mass. Additionally, much of the available information is fragmented, disorganized, or focused on specific etiologies. In addition, although there is literature related to the diagnostic accuracy of individual tests, there is little guidance about rational sequencing of tests in the course of clinical care. This guideline strives to bring a coherent, evidence-based, multidisciplinary perspective to the evaluation of the neck mass with the intention to facilitate prompt diagnosis and enhance patient outcomes. Purpose The primary purpose of this guideline is to promote the efficient, effective, and accurate diagnostic workup of neck masses to ensure that adults with potentially malignant disease receive prompt diagnosis and intervention to optimize outcomes. Specific goals include reducing delays in diagnosis of HNSCC; promoting appropriate testing, including imaging, pathologic evaluation, and empiric medical therapies; reducing inappropriate testing; and promoting appropriate

  18. Evaluation of Approaches to Analyzing Continuous Correlated Eye Data When Sample Size Is Small.

    Science.gov (United States)

    Huang, Jing; Huang, Jiayan; Chen, Yong; Ying, Gui-Shuang

    2018-02-01

    To evaluate the performance of commonly used statistical methods for analyzing continuous correlated eye data when sample size is small. We simulated correlated continuous data from two designs: (1) two eyes of a subject in two comparison groups; (2) two eyes of a subject in the same comparison group, under various sample size (5-50), inter-eye correlation (0-0.75) and effect size (0-0.8). Simulated data were analyzed using paired t-test, two sample t-test, Wald test and score test using the generalized estimating equations (GEE) and F-test using linear mixed effects model (LMM). We compared type I error rates and statistical powers, and demonstrated analysis approaches through analyzing two real datasets. In design 1, paired t-test and LMM perform better than GEE, with nominal type 1 error rate and higher statistical power. In design 2, no test performs uniformly well: two sample t-test (average of two eyes or a random eye) achieves better control of type I error but yields lower statistical power. In both designs, the GEE Wald test inflates type I error rate and GEE score test has lower power. When sample size is small, some commonly used statistical methods do not perform well. Paired t-test and LMM perform best when two eyes of a subject are in two different comparison groups, and t-test using the average of two eyes performs best when the two eyes are in the same comparison group. When selecting the appropriate analysis approach the study design should be considered.

  19. Multi-Center Evaluation of the Automated Immunohematology Instrument, the ORTHO VISION Analyzer.

    Science.gov (United States)

    Aysola, Agnes; Wheeler, Leslie; Brown, Richard; Denham, Rebecca; Colavecchia, Connie; Pavenski, Katerina; Krok, Elizabeth; Hayes, Chelsea; Klapper, Ellen

    2017-02-01

    ORTHO VISION Analyzer (Vision), is an immunohematology instrument using ID-MT gel card technology with digital image processing. It has a continuous, random sample access with STAT priority processing. The efficiency and ease of operation of Vision was evaluated at 5 medical centers. De-identified patient samples were tested on the ORTHO ProVue Analyzer (ProVue) and repeated on the Vision mimicking the daily workload pattern. Turnaround times (TAT) were collected and compared. Operators rated key features of the analyzer on a scale of 1 to 5. A total of 507 samples were tested on both instruments at the 5 trial sites. The mean TAT (SD) were 31.6 minutes (5.5) with Vision and 35.7 minutes (8.4) with ProVue, which renders a 12% reduction. Type and screens were performed on 381 samples; the mean TAT (SD) was 32.2 minutes (4.5) with Vision and 37.0 minutes (7.4) with ProVue. Antibody identification with eleven panel cells was performed on 134 samples on Vision; TAT (SD) was 43.2 minutes (8.3). The installation, training, configuration, maintenance and validation processes are all streamlined to provide a short implementation time. The average rating of main functions by the operators was 4.1 to 4.8. Opportunities for improvement, such as flexibility with editing QC results, maintenance schedule, and printing options were identified. The capabilities to perform serial dilutions, to accept pediatric tubes, and review results by e-Connectivity are enhancements over the ProVue. Vision provides shorter TAT compared to ProVue. Every site described a positive experience using Vision. © American Society for Clinical Pathology, 2017. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

  20. Development and evaluation of a computer-aided system for analyzing human error in railway operations

    International Nuclear Information System (INIS)

    Kim, Dong San; Baek, Dong Hyun; Yoon, Wan Chul

    2010-01-01

    As human error has been recognized as one of the major contributors to accidents in safety-critical systems, there has been a strong need for techniques that can analyze human error effectively. Although many techniques have been developed so far, much room for improvement remains. As human error analysis is a cognitively demanding and time-consuming task, it is particularly necessary to develop a computerized system supporting this task. This paper presents a computer-aided system for analyzing human error in railway operations, called Computer-Aided System for Human Error Analysis and Reduction (CAS-HEAR). It supports analysts to find multiple levels of error causes and their causal relations by using predefined links between contextual factors and causal factors as well as links between causal factors. In addition, it is based on a complete accident model; hence, it helps analysts to conduct a thorough analysis without missing any important part of human error analysis. A prototype of CAS-HEAR was evaluated by nine field investigators from six railway organizations in Korea. Its overall usefulness in human error analysis was confirmed, although development of its simplified version and some modification of the contextual factors and causal factors are required in order to ensure its practical use.

  1. Sonography and cytology in the evaluation of salivary gland masses

    International Nuclear Information System (INIS)

    Gozzi, G.; Bazzochi, M.; Vasciaveo, A.; Bassini, A.; Bellis, G.B.; Di Bonito, L.

    1991-01-01

    The contribution of the combined use of US and cytology is evaluated in the diagnosis of masses in yhe salivary glands and adjacent structures. US had 87.2% sensitivity in locating the mass; its accuracy in defining both phisical structure and benign/malignant nature of the lesion was 91% and 74% respectively. Thus US, after demonstrating a lesion, does not always allow the exact definition of its characteristic. In many of these cases, other imaging modalities do not help either. In our series of cases, cytology allowed an unquestionable diagnosis to be made in 87.2% of cases, and the combined use of US and cytology rose the figure to 97%. The only limitation is the evaluation of the deep extent of large masses: in such cases CT or, if available, MR imaging are recommended

  2. Evaluation of a portable automated serum chemistry analyzer for field assessment of harlequin ducks, Histrionicus histrionicus

    Science.gov (United States)

    Stoskopf, Michael K.; Mulcahy, Daniel M.; Esler, Daniel N.

    2010-01-01

    A portable analytical chemistry analyzer was used to make field assessments of wild harlequin ducks (Histrionicus histrionicus) in association with telemetry studies of winter survival in Prince William Sound, Alaska. We compared serum chemistry results obtained on-site with results from a traditional laboratory. Particular attention was paid to serum glucose and potassium concentrations as potential indicators of high-risk surgical candidates based on evaluation of the field data. The median differential for glucose values ( = 8 2) between methods was 0.6 mmol/L (quartiles 0.3 and 0.9 mmol/L) with the median value higher when assayed on site. Analysis of potassium on site returned a median of 2.7 mmol/L ( = 8 8 ; quartiles 2.4 and 3.0 mmol/L). Serum potassium values were too low for quantitation by the traditional laboratory. Changes in several serum chemistry values following a three-day storm during the study support the value of on site evaluation of serum potassium to identify presurgical patients with increased anesthetic risk.

  3. Analyzing THE PLACE FOR THE EVENT-type Metonymies from the Perspective of Negative Evaluative Factors

    Directory of Open Access Journals (Sweden)

    Nami Arimitsu

    Full Text Available This paper has two objectives. First, by analyzing THE PLACE FOR THE EVENT-type metonymies, this paper points out that it is mainly negative events that are expressed by this type of metonymy. Second, this paper reveals the motivations of those THE PLACE FOR THE EVENT-type metonymies that express negative events. Metonymies are widely investigated along with the views of Lakoff and Johnson (1980, and their oppositional semantic aspects are pointed out by Voßhagen (1999. However, none of the previous studies focused on the nature of THE PLACE FOR THE EVENT-type metonymies from the perspective of negative evaluation, euphemism, and politeness. "Let's not let Thailand become another Vietnam" expresses the Vietnam War and all the tragedies behind it. Speakers refrain from expressing negative evaluative aspects from a euphemistic perspective and try to behave politely through hiding the exact expression, and listeners can also easily understand THE PLACE FOR THE EVENT-type metonymies that express negative events, since negative events are much more highly marked and intensified, as well as more prominent, than are positive ones.

  4. Ages of young star clusters, massive blue stragglers, and the upper mass limit of stars: Analyzing age-dependent stellar mass functions

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, F. R. N.; Izzard, R. G.; Langer, N.; Stolte, A.; Hußmann, B. [Argelander-Institut für Astronomie der Universität Bonn, Auf dem Hügel 71, D-53121 Bonn (Germany); De Mink, S. E. [Observatories of the Carnegie Institution for Science, 813 Santa Barbara St, Pasadena, CA 91101 (United States); De Koter, A.; Sana, H. [Astronomical Institute " Anton Pannekoek" , Amsterdam University, Science Park 904, 1098 XH, Amsterdam (Netherlands); Gvaramadze, V. V. [Sternberg Astronomical Institute, Lomonosov Moscow State University, Universitetskij Pr. 13, Moscow 119992 (Russian Federation); Liermann, A., E-mail: fschneid@astro.uni-bonn.de [Max Planck Institut für Radioastronomie, Auf dem Hügel 69, D-53121 Bonn (Germany)

    2014-01-10

    Massive stars rapidly change their masses through strong stellar winds and mass transfer in binary systems. The latter aspect is important for populations of massive stars as more than 70% of all O stars are expected to interact with a binary companion during their lifetime. We show that such mass changes leave characteristic signatures in stellar mass functions of young star clusters that can be used to infer their ages and to identify products of binary evolution. We model the observed present-day mass functions of the young Galactic Arches and Quintuplet star clusters using our rapid binary evolution code. We find that the shaping of the mass function by stellar wind mass loss allows us to determine the cluster ages as 3.5 ± 0.7 Myr and 4.8 ± 1.1 Myr, respectively. Exploiting the effects of binary mass exchange on the cluster mass function, we find that the most massive stars in both clusters are rejuvenated products of binary mass transfer, i.e., the massive counterpart of classical blue straggler stars. This resolves the problem of an apparent age spread among the most luminous stars exceeding the expected duration of star formation in these clusters. We perform Monte Carlo simulations to probe stochastic sampling, which support the idea of the most massive stars being rejuvenated binary products. We find that the most massive star is expected to be a binary product after 1.0 ± 0.7 Myr in Arches and after 1.7 ± 1.0 Myr in Quintuplet. Today, the most massive 9 ± 3 stars in Arches and 8 ± 3 in Quintuplet are expected to be such objects. Our findings have strong implications for the stellar upper mass limit and solve the discrepancy between the claimed 150 M {sub ☉} limit and observations of four stars with initial masses of 165-320 M {sub ☉} in R136 and of supernova 2007bi, which is thought to be a pair-instability supernova from an initial 250 M {sub ☉} star. Using the stellar population of R136, we revise the upper mass limit to values in the range

  5. Ages of young star clusters, massive blue stragglers, and the upper mass limit of stars: Analyzing age-dependent stellar mass functions

    International Nuclear Information System (INIS)

    Schneider, F. R. N.; Izzard, R. G.; Langer, N.; Stolte, A.; Hußmann, B.; De Mink, S. E.; Anton Pannekoek, Amsterdam University, Science Park 904, 1098 XH, Amsterdam (Netherlands))" data-affiliation=" (Astronomical Institute Anton Pannekoek, Amsterdam University, Science Park 904, 1098 XH, Amsterdam (Netherlands))" >De Koter, A.; Anton Pannekoek, Amsterdam University, Science Park 904, 1098 XH, Amsterdam (Netherlands))" data-affiliation=" (Astronomical Institute Anton Pannekoek, Amsterdam University, Science Park 904, 1098 XH, Amsterdam (Netherlands))" >Sana, H.; Gvaramadze, V. V.; Liermann, A.

    2014-01-01

    Massive stars rapidly change their masses through strong stellar winds and mass transfer in binary systems. The latter aspect is important for populations of massive stars as more than 70% of all O stars are expected to interact with a binary companion during their lifetime. We show that such mass changes leave characteristic signatures in stellar mass functions of young star clusters that can be used to infer their ages and to identify products of binary evolution. We model the observed present-day mass functions of the young Galactic Arches and Quintuplet star clusters using our rapid binary evolution code. We find that the shaping of the mass function by stellar wind mass loss allows us to determine the cluster ages as 3.5 ± 0.7 Myr and 4.8 ± 1.1 Myr, respectively. Exploiting the effects of binary mass exchange on the cluster mass function, we find that the most massive stars in both clusters are rejuvenated products of binary mass transfer, i.e., the massive counterpart of classical blue straggler stars. This resolves the problem of an apparent age spread among the most luminous stars exceeding the expected duration of star formation in these clusters. We perform Monte Carlo simulations to probe stochastic sampling, which support the idea of the most massive stars being rejuvenated binary products. We find that the most massive star is expected to be a binary product after 1.0 ± 0.7 Myr in Arches and after 1.7 ± 1.0 Myr in Quintuplet. Today, the most massive 9 ± 3 stars in Arches and 8 ± 3 in Quintuplet are expected to be such objects. Our findings have strong implications for the stellar upper mass limit and solve the discrepancy between the claimed 150 M ☉ limit and observations of four stars with initial masses of 165-320 M ☉ in R136 and of supernova 2007bi, which is thought to be a pair-instability supernova from an initial 250 M ☉ star. Using the stellar population of R136, we revise the upper mass limit to values in the range 200-500 M ☉ .

  6. Ages of Young Star Clusters, Massive Blue Stragglers, and the Upper Mass Limit of Stars: Analyzing Age-dependent Stellar Mass Functions

    Science.gov (United States)

    Schneider, F. R. N.; Izzard, R. G.; de Mink, S. E.; Langer, N.; Stolte, A.; de Koter, A.; Gvaramadze, V. V.; Hußmann, B.; Liermann, A.; Sana, H.

    2014-01-01

    Massive stars rapidly change their masses through strong stellar winds and mass transfer in binary systems. The latter aspect is important for populations of massive stars as more than 70% of all O stars are expected to interact with a binary companion during their lifetime. We show that such mass changes leave characteristic signatures in stellar mass functions of young star clusters that can be used to infer their ages and to identify products of binary evolution. We model the observed present-day mass functions of the young Galactic Arches and Quintuplet star clusters using our rapid binary evolution code. We find that the shaping of the mass function by stellar wind mass loss allows us to determine the cluster ages as 3.5 ± 0.7 Myr and 4.8 ± 1.1 Myr, respectively. Exploiting the effects of binary mass exchange on the cluster mass function, we find that the most massive stars in both clusters are rejuvenated products of binary mass transfer, i.e., the massive counterpart of classical blue straggler stars. This resolves the problem of an apparent age spread among the most luminous stars exceeding the expected duration of star formation in these clusters. We perform Monte Carlo simulations to probe stochastic sampling, which support the idea of the most massive stars being rejuvenated binary products. We find that the most massive star is expected to be a binary product after 1.0 ± 0.7 Myr in Arches and after 1.7 ± 1.0 Myr in Quintuplet. Today, the most massive 9 ± 3 stars in Arches and 8 ± 3 in Quintuplet are expected to be such objects. Our findings have strong implications for the stellar upper mass limit and solve the discrepancy between the claimed 150 M ⊙ limit and observations of four stars with initial masses of 165-320 M ⊙ in R136 and of supernova 2007bi, which is thought to be a pair-instability supernova from an initial 250 M ⊙ star. Using the stellar population of R136, we revise the upper mass limit to values in the range 200-500 M ⊙.

  7. Development and evaluation of a workpiece temperature analyzer (WPTA) for industrial furances (Phase 1)

    Energy Technology Data Exchange (ETDEWEB)

    1991-10-01

    This project is directed toward the research, development, and evaluation of a viable commercial product-a workpiece temperature measurement analyzer (WPTA) for fired furnaces based on unique radiation properties of surfaces. This WPTA will provide for more uniform, higher quality products and reduce product rejects as well as permit the optimum use of energy. The WPTA may also be utilized in control system applications including metal heat treating, forging furnaces, and ceramic firing furnaces. A large market also exists in the chemical process and refining industry. WPTA applications include the verification of product temperature/time cycles, and use as a front-end sensor for automatic feedback control systems. This report summarizes the work performed in Phase 1 of this three-phase project. The work Phase 1 included the application evaluation; the evaluation of present technologies and limitations; and the development of a preliminary conceptual WPTA design, including identification of technical and economic benefits. Recommendations based on the findings of this report include near-term enhancement of the capabilities of the Pyrolaser, and long-term development of an instrument based on Raman Spectroscopy. Development of the Pyrofiber, fiberoptics version of the Pyrolaser, will be a key to solving present problems involving specularity, measurement angle, and costs of multipoint measurement. Extending the instrument's measurement range to include temperatures below 600{degrees}C will make the product useful for a wider range of applications. The development of Raman Spectroscopy would result in an instrument that could easily be adapted to incorporate a wealth of additional nondestructive analytical capabilities, including stress/stain indication, crystallography, species concentrations, corrosion studies, and catalysis studies, in addition to temperature measurement. 9 refs., 20 figs., 16 tabs.

  8. Evaluation of mass distribution data from 252Cf spontaneous fission

    International Nuclear Information System (INIS)

    Liu Tingjin

    2003-01-01

    The mass distribution data of 252 Cf spontaneous fission were evaluated based on 7 sets of available experimental data. The measured data were corrected for the standards and γ intensity used by using the new evaluated ones. The errors were made necessary adjusting. The evaluated experimental data were fitted with spline function without any restriction and with symmetric restriction. These two sets of fit data were recommended as reference data of the mass distribution of 252 Cf spontaneous fission. The errors of the recommended data were considerably reduced comparing with the measured ones. The light and heavy peaks are not completely symmetric. Also there are fine structures on the right side of the light peak at A=109-111 and left side of the heavy peak at A=137-139. These should be paid attention and studied further. (author)

  9. Objective evaluation of analyzer performance based on a retrospective meta-analysis of instrument validation studies: point-of-care hematology analyzers.

    Science.gov (United States)

    Cook, Andrea M; Moritz, Andreas; Freeman, Kathleen P; Bauer, Natali

    2017-06-01

    Information on quality requirements and objective evaluation of performance of veterinary point-of-care analyzers (POCAs) is scarce. The study was aimed at assessing observed total errors (TE obs s) for veterinary hematology POCAs via meta-analysis and comparing TE obs to allowable total error (TE a ) specifications based on experts' opinions. The TE obs for POCAs (impedance and laser-based) was calculated based on data from instrument validation studies published between 2006 and 2013 as follows: TE obs = 2 × CV [%] + bias [%]. The CV was taken from published studies; the bias was estimated from the regression equation at 2 different concentration levels of measurands. To fulfill quality requirements, TE obs should be 60% of analyzers showed TE obs hematology variables, respectively. For the CBC, TE obs was TE a (data from 3 analyzers). This meta-analysis is considered a pilot study. Experts' requirements (TE obs < TE a ) were fulfilled for most measurands except HGB (due to instrument-related bias for the ADVIA 2120) and platelet counts. Available data on the WBC differential count suggest an analytic bias, so nonstatistical quality control is recommended. © 2017 American Society for Veterinary Clinical Pathology.

  10. Evaluation of errors for mass-spectrometric analysis with surface-ionization type mass-spectrometer (statistical evaluation of mass-discrimination effect)

    International Nuclear Information System (INIS)

    Wada, Y.

    1981-01-01

    The surface-ionization type mass-spectrometer is widely used as an apparatus for quality assurance, accountability and safeguarding of nuclear materials, and for this analysis it has become an important factor to statistically evaluate an analytical error which consists of a random error and a systematic error. The major factor of this systematic error was the mass-discrimination effect. In this paper, various assays for evaluating the factor of variation on the mass-discrimination effect were studied and the data obtained were statistically evaluated. As a result of these analyses, it was proved that the factor of variation on the mass-discrimination effect was not attributed to the acid concentration of sample, sample size on the filament and supplied voltage for a multiplier, but mainly to the filament temperature during the mass-spectrometric analysis. The mass-discrimination effect values β which were usually calculated from the measured data of uranium, plutonium or boron isotopic standard sample were not so significant dependently of the difference of U-235, Pu-239 or B-10 isotopic abundance. Furthermore, in the case of U and Pu, measurement conditions and the mass range of these isotopes were almost similar, and these values β were not statistically significant between U and Pu. On the other hand, the value β for boron was about a third of the value β for U or Pu, but compared with the coefficient of the correction on the mass-discrimination effect for the difference of mass-number, ΔM, these coefficient values were almost the same among U, Pu, and B.As for the isotopic analysis error of U, Pu, Nd and B, it was proved that the isotopic abundance of these elements and the isotopic analysis error were in a relationship of quadratic curves on a logarithmic-logarithmic scale

  11. Evaluate, Analyze, Describe (EAD: Confronting Underlying Issues of Racism and Other Prejudices for Effective Intercultural Communication

    Directory of Open Access Journals (Sweden)

    Daniel Velasco

    2015-09-01

    Full Text Available Racism and other prejudices have hindered efforts to diversify and further many fields, including education, psychology, politics, law, and healthcare (Race for Opportunity, 2010. Although there are many ways to combat these prejudices, intercultural communication continues to be a vital component in assisting individuals and groups with valuing the past, understanding the present, and preparing for the future of communication in a global society (Sadri and Flammia, 2011, p. 19. This paper provides a brief overview of pertinent research and major theories related to communicating with people of different cultural backgrounds, as well as useful techniques and strategies to use when teaching in international or multinational classrooms, and working or consulting in international or multinational companies, organizations, and educational institutions. It also includes data collected via surveys and interviews that helps to shed light on underlying issues of racism and discontent in Japanese and Nigerian populations within Japan, and concludes with a description of a new approach to one of the most common intercultural communication exercises called the E.A.D. (Evaluate, Analyze, Describe. While this exercise has proved to increase cultural awareness and open the lines of communication between individuals from various cultural and lingual backgrounds, research also shows that other strategies may be necessary to achieve desired levels of communication.

  12. Evaluation of colorimetric assays for analyzing reductively methylated proteins: Biases and mechanistic insights.

    Science.gov (United States)

    Brady, Pamlea N; Macnaughtan, Megan A

    2015-12-15

    Colorimetric protein assays, such as the Coomassie blue G-250 dye-binding (Bradford) and bicinchoninic acid (BCA) assays, are commonly used to quantify protein concentration. The accuracy of these assays depends on the amino acid composition. Because of the extensive use of reductive methylation in the study of proteins and the importance of biological methylation, it is necessary to evaluate the impact of lysyl methylation on the Bradford and BCA assays. Unmodified and reductively methylated proteins were analyzed using the absorbance at 280 nm to standardize the concentrations. Using model compounds, we demonstrate that the dimethylation of lysyl ε-amines does not affect the proteins' molar extinction coefficients at 280 nm. For the Bradford assay, the responses (absorbance per unit concentration) of the unmodified and reductively methylated proteins were similar, with a slight decrease in the response upon methylation. For the BCA assay, the responses of the reductively methylated proteins were consistently higher, overestimating the concentrations of the methylated proteins. The enhanced color formation in the BCA assay may be due to the lower acid dissociation constants of the lysyl ε-dimethylamines compared with the unmodified ε-amine, favoring Cu(II) binding in biuret-like complexes. The implications for the analysis of biologically methylated samples are discussed. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Regioisomers of octanoic acid-containing structured triacylglycerols analyzed by tandem mass spectrometry using ammonia negative ion chemical ionization

    DEFF Research Database (Denmark)

    Kurvinen, J.P.; Mu, Huiling; Kallio, H.

    2001-01-01

    Tandem mass spectrometry based on ammonia negative ion chemical ionization and sample introduction via direct exposure probe was applied to analysis of regioisomeric structures of octanoic acid containing structured triacylglycerols (TAG) of type MML, MLM, MLL, and LML (M, medium-chain fatty acid...

  14. Benefit-risk evaluation of mammographic mass screening

    International Nuclear Information System (INIS)

    Sato, Nobuo; Ogura, Toshihiro

    1990-01-01

    This study evaluated the benefit-risk balance of mammography in mass screening by using survival rates from 3000 breast cancer patients at the Japanese Foundation for Cancer Research Institute Hospital. Because the number of participants in mammographic mass screening was small, asymptomatic patients with pathologically proven early breast cancer were categorized as the screenee group. Symptomatic patients were categorized as the patient group. Survival rates were compared in both the screenee and the patient groups. Based on the difference in areas of survival curves between screenees and patients, the ratio of person-year gain (PYG) to person-year lost (PYL) was obtained. The ratio of PYG to PYL was multiplied by the detection rate resulting from a particular screening program to obtain the benefit/risk ratio. The detection rate of nonpalpable breast cancer was 15 times higher in the screenee group than the patient group. Breast cancer was detected in 7 (0.85%) of 824 patients in the screenee group. Even when mammographic mass screening was started at the age of 30, the benefit of mammography was far superior to the risk. The number of participants in mass screening stratified by age may be required for the conclusion of the benefit-risk balance of mammography in mass screening. (N.K.)

  15. Quality requirements for veterinary hematology analyzers in small animals-a survey about veterinary experts' requirements and objective evaluation of analyzer performance based on a meta-analysis of method validation studies: bench top hematology analyzer.

    Science.gov (United States)

    Cook, Andrea M; Moritz, Andreas; Freeman, Kathleen P; Bauer, Natali

    2016-09-01

    Scarce information exists about quality requirements and objective evaluation of performance of large veterinary bench top hematology analyzers. The study was aimed at comparing the observed total error (TEobs ) derived from meta-analysis of published method validation data to the total allowable error (TEa ) for veterinary hematology variables in small animals based on experts' opinions. Ideally, TEobs should be hematology analyzers (ADVIA 2120; Sysmex XT2000iV, and CellDyn 3500) was calculated based on method validation studies published between 2005 and 2013 (n = 4). The percent TEobs = 2 * CV (%) + bias (%). The CV was derived from published studies except for the ADVIA 2120 (internal data), and bias was estimated from the regression equation. A total of 41 veterinary experts (19 diplomates, 8 residents, 10 postgraduate students, 4 anonymous specialists) responded. The proposed range of TEa was wide, but generally ≤ 20%. The TEobs was < TEa for all variables and analyzers except for canine and feline HGB (high bias, low CV) and platelet counts (high bias, high CV). Overall, veterinary bench top analyzers fulfilled experts' requirements except for HGB due to method-related bias, and platelet counts due to known preanalytic/analytic issues. © 2016 American Society for Veterinary Clinical Pathology.

  16. Discussion of the Improved Methods for Analyzing a Cantilever Beam Carrying a Tip-Mass under Base Excitation

    Directory of Open Access Journals (Sweden)

    Wang Hongjin

    2014-01-01

    Full Text Available Two improved analytical methods of calculations for natural frequencies and mode shapes of a uniform cantilever beam carrying a tip-mass under base excitation are presented based on forced vibration theory and the method of separation of variables, respectively. The cantilever model is simplified in detail by replacing the tip-mass with an equivalent inertial force and inertial moment acting at the free end of the cantilever based on D’Alembert’s principle. The concentrated equivalent inertial force and inertial moment are further represented as distributed loads using Dirac Delta Function. In this case, some typical natural frequencies and mode shapes of the cantilever model are calculated by the improved and unimproved analytical methods. The comparing results show that, after improvement, these two methods are in extremely good agreement with each other even the offset distance between the gravity center of the tip-mass and the attachment point is large. As further verification, the transient and steady displacement responses of the cantilever system under a sine base excitation are presented in which two improved methods are separately utilized. Finally, an experimental cantilever system is fabricated and the theoretical displacement responses are validated by the experimental measurements successfully.

  17. The transmission theory of electrostatic analyzer in six dimensional phase space and the concept design of a supersensitive mass spectrometer beam line for HI-13 tandem accelerator

    International Nuclear Information System (INIS)

    Guan Xialing; Cao Qingxi; Zhang Jie; Ye Jingping

    1986-01-01

    It follows from the motion equations of charged particle in curvilinear coordinates system that the transfer matrix of electrostatic analyzer was derived in six dimensional phase space. In accordance with these matrixes, the concept design of the supersensitive mass spectrometer beam line for HI-13 tandem accelerator was calculated

  18. The lipidomes of vesicular stomatitis virus, semliki forest virus, and the host plasma membrane analyzed by quantitative shotgun mass spectrometry

    DEFF Research Database (Denmark)

    Kalvodova, Lucie; Sampaio, Julio L; Cordo, Sandra

    2009-01-01

    kidney cells can be infected by two different viruses, namely, vesicular stomatitis virus and Semliki Forest virus, from the Rhabdoviridae and Togaviridae families, respectively. We purified the host plasma membrane and the two different viruses after exit from the host cells and analyzed the lipid...

  19. Stability and Application of Reactive Nitrogen and Oxygen Species-Induced Hemoglobin Modifications in Dry Blood Spots As Analyzed by Liquid Chromatography Tandem Mass Spectrometry.

    Science.gov (United States)

    Chen, Hauh-Jyun Candy; Fan, Chih-Huang; Yang, Ya-Fen

    2016-12-19

    Dried blood spot (DBS) is an emerging microsampling technique for the bioanalysis of small molecules, including fatty acids, metabolites, drugs, and toxicants. DBS offers many advantages as a sample format including easy sample collection and cheap sample shipment. Hemoglobin adducts have been recognized as a suitable biomarker for monitoring chemical exposure. We previously reported that certain modified peptides in hemoglobin derived from reactive chlorine, nitrogen, and oxygen species are associated with factors including smoking, diabetes mellitus, and aging. However, the stability of these oxidation-induced modifications of hemoglobin remains unknown and whether they can be formed artifactually during storage of DBS. To answer these questions, globin extracted from the DBS cards was analyzed, and the stability of the modifications was evaluated. After storage of the DBS cards at 4 °C or room temperature up to 7 weeks, we isolated globin from a quarter of the spot every week. The extents of 11 sites and types of post-translational modifications (PTMs), including nitration and nitrosylation of tyrosine and oxidation of cysteine and methionine residues, in human hemoglobin were measured in the trypsin digest by nanoflow liquid chromatography-nanospray ionization tandem mass spectrometry (nanoLC-NSI/MS/MS) using selected reaction monitoring. The extents of all these PTMs are stable within 14 days when stored on DBS at room temperature and at 4 °C, while those from direct extraction of fresh blood are stable for at least 8 weeks when stored as an aqueous solution at -20 °C. Extraction of globin from a DBS card is of particular importance for hemolytic blood samples. To our knowledge, this is the first report on the stability of oxidative modifications of hemoglobin on DBSs, which are stable for 14 days under ambient conditions (room temperature, in air). Therefore, it is feasible and convenient to analyze these hemoglobin modifications from DBSs in studies

  20. The application of an optical Fourier spectrum analyzer on detecting defects in mass-produced satellite photographs

    Science.gov (United States)

    Athale, R.; Lee, S. H.

    1976-01-01

    Various defects in mass-produced pictures transmitted to earth from a satellite are investigated. It is found that the following defects are readily detectable via Fourier spectrum analysis: (1) bit slip, (2) breakup causing loss of image, and (3) disabled track at the top of the imagery. The scratches made on the film during mass production, which are difficult to detect by visual observation, also show themselves readily in Fourier spectrum analysis. A relation is established between the number of scratches, their width and depth and the intensity of their Fourier spectra. Other defects that are found to be equally suitable for Fourier spectrum analysis or visual (image analysis) detection are synchronous loss without blurring of image, and density variation in gray scale. However, the Fourier spectrum analysis is found to be unsuitable for detection of such defects as pin holes, annotation error, synchronous loss with blurring of images, and missing image in the beginning of the work order. The design of an automated, real time system, which will reject defective films, is treated.

  1. Analyzing high resolution topography for advancing the understanding of mass and energy transfer through landscapes: A review

    Science.gov (United States)

    Passaiacquaa, Paola; Belmont, Patrick; Staley, Dennis M.; Simley, Jeffery; Arrowsmith, J. Ramon; Bode, Collin A.; Crosby, Christopher; DeLong, Stephen; Glenn, Nancy; Kelly, Sara; Lague, Dimitri; Sangireddy, Harish; Schaffrath, Keelin; Tarboton, David; Wasklewicz, Thad; Wheaton, Joseph

    2015-01-01

    The study of mass and energy transfer across landscapes has recently evolved to comprehensive considerations acknowledging the role of biota and humans as geomorphic agents, as well as the importance of small-scale landscape features. A contributing and supporting factor to this evolution is the emergence over the last two decades of technologies able to acquire high resolution topography (HRT) (meter and sub-meter resolution) data. Landscape features can now be captured at an appropriately fine spatial resolution at which surface processes operate; this has revolutionized the way we study Earth-surface processes. The wealth of information contained in HRT also presents considerable challenges. For example, selection of the most appropriate type of HRT data for a given application is not trivial. No definitive approach exists for identifying and filtering erroneous or unwanted data, yet inappropriate filtering can create artifacts or eliminate/distort critical features. Estimates of errors and uncertainty are often poorly defined and typically fail to represent the spatial heterogeneity of the dataset, which may introduce bias or error for many analyses. For ease of use, gridded products are typically preferred rather than the more information-rich point cloud representations. Thus many users take advantage of only a fraction of the available data, which has furthermore been subjected to a series of operations often not known or investigated by the user. Lastly, standard HRT analysis work-flows are yet to be established for many popular HRT operations, which has contributed to the limited use of point cloud data.In this review, we identify key research questions relevant to the Earth-surface processes community within the theme of mass and energy transfer across landscapes and offer guidance on how to identify the most appropriate topographic data type for the analysis of interest. We describe the operations commonly performed from raw data to raster products and

  2. Quality in mass-produced insects: definition and evaluation

    International Nuclear Information System (INIS)

    Chambers, D.L.

    1975-01-01

    The insect that is mass-produced and released in a control programme is in effect a biological bullet, a self-guided missile designed to deliver a beneficial effect against a pest insect. The ability of the released insect to achieve this objective may be influenced in many ways. The control of the quality of mass-produced insects must include an understanding of the behavioural components critical to their success and an evaluation of their performance based upon these behavioural components. The paper discusses some of the principles and techniques being used and developed to study behavioural performance and quality. Included are discussions of tests of: vigour, irritability, activity, sound production, response thresholds, reproductive preference and drive, biotic potential, and others. (author)

  3. Correction for the 17O interference in δ(13C) measurements when analyzing CO2 with stable isotope mass spectrometry

    Science.gov (United States)

    Coplen, Tyler B.; Brand, Willi A.; Assonov, Sergey S.

    2010-01-01

    Measurements of δ(13C) determined on CO2 with an isotope-ratio mass spectrometer (IRMS) must be corrected for the amount of 17O in the CO2. For data consistency, this must be done using identical methods by different laboratories. This report aims at unifying data treatment for CO2 IRMS by proposing (i) a unified set of numerical values, and (ii) a unified correction algorithm, based on a simple, linear approximation formula. Because the oxygen of natural CO2 is derived mostly from the global water pool, it is recommended that a value of 0.528 be employed for the factor λ, which relates differences in 17O and 18O abundances. With the currently accepted N(13C)/N(12C) of 0.011 180(28) in VPDB (Vienna Peedee belemnite) reevaluation of data yields a value of 0.000 393(1) for the oxygen isotope ratio N(17O)/N(16O) of the evolved CO2. The ratio of these quantities, a ratio of isotope ratios, is essential for the 17O abundance correction: [N(17O)/N(16O)]/[N(13C)/N(12C)] = 0.035 16(8). The equation [δ(13C) ≈ 45δVPDB-CO2 + 2 17R/13R (45δVPDB-CO2 – λ46δVPDB-CO2)] closely approximates δ(13C) values with less than 0.010 ‰ deviation for normal oxygen-bearing materials and no more than 0.026 ‰ in extreme cases. Other materials containing oxygen of non-mass-dependent isotope composition require a more specific data treatment. A similar linear approximation is also suggested for δ(18O). The linear approximations are easy to implement in a data spreadsheet, and also help in generating a simplified uncertainty budget.

  4. Determination of δ13C, δ15N, or δ34S by isotope-ratio-monitoring mass spectrometry using an elemental analyzer

    Science.gov (United States)

    Johnson, Craig A.; Stricker, Craig A.; Gulbransen, Cayce A.; Emmons, Matthew P.

    2018-02-14

    This report describes procedures used in the Geology, Geophysics, and Geochemistry Science Center of the U.S. Geological Survey in Denver, Colorado, to determine the stable-isotope ratios 13C/12C, 15N/14N, and 34S/32S in solid materials. The procedures use elemental analyzers connected directly to gas-source isotope-ratio mass spectrometers. A different elemental–analyzer–mass-spectrometer system is used for 13C/12C and 15N/14N than is used for 34S/32S to accommodate differences in reagents, catalysts, and instrument settings.

  5. Weapons of Mass Destruction Technology Evaluation and Training Range

    Energy Technology Data Exchange (ETDEWEB)

    Kevin Larry Young

    2009-05-01

    The Idaho National Laboratory (INL) has a long history for providing technology evaluation and training for military and other federal level Weapons of Mass Destruction (WMD) response agencies. Currently there are many federal organizations and commercial companies developing technologies related to detecting, assessing, mitigating and protecting against hazards associated with a WMD event. Unfortunately, very few locations exist within the United States where WMD response technologies are realistically field tested and evaluated using real chemical, biological, radiological, nuclear and explosive materials. This is particularly true with biological and radiological hazards. Related to this lack of adequate WMD, multi-hazard technology testing capability is the shortage of locations where WMD response teams can train using actual chemical, biological, and radiological material or highly realistic simulates. In response to these technology evaluation and training needs, the INL has assembled a consortium of subject matter experts from existing programs and identified dedicated resources for the purpose of establishing an all-hazards, WMD technology evaluation and training range. The author describes the challenges associated with creating the all-hazards WMD technology evaluation and training range and lists the technical, logistical and financial benefits of an all-hazards technology evaluation and training range. Current resources and capabilities for conducting all-hazard technology evaluation and training at the INL are identified. Existing technology evaluation and training programs at the INL related to radiological, biological and chemical hazards are highlighted, including successes and lessons learned. Finally, remaining gaps in WMD technology evaluation and training capabilities are identified along with recommendations for closing those gaps.

  6. Association between magnetic resonance imaging patterns and baseline disease features in multiple myeloma: analyzing surrogates of tumour mass and biology

    Energy Technology Data Exchange (ETDEWEB)

    Mai, Elias K.; Merz, Maximilian; Shah, Sofia; Hillengass, Michaela; Wagner, Barbara; Hose, Dirk; Raab, M.S. [University Hospital Heidelberg, Department of Internal Medicine V, Heidelberg (Germany); Hielscher, Thomas [German Cancer Research Center, Division of Biostatistics, Heidelberg (Germany); Kloth, Jost K.; Weber, Marc-Andre [University Hospital of Heidelberg, Clinic of Diagnostic and Interventional Radiology, Heidelberg (Germany); Jauch, Anna [University Hospital of Heidelberg, Institute of Human Genetics, Heidelberg (Germany); Delorme, Stefan [German Cancer Research Center, Department of Radiology, Heidelberg (Germany); Goldschmidt, Hartmut [University Hospital Heidelberg, Department of Internal Medicine V, Heidelberg (Germany); National Center for Tumor Diseases (NCT) Heidelberg, Heidelberg (Germany); Hillengass, Jens [University Hospital Heidelberg, Department of Internal Medicine V, Heidelberg (Germany); German Cancer Research Center, Department of Radiology, Heidelberg (Germany)

    2016-11-15

    To assess associations between bone marrow infiltration patterns and localization in magnetic resonance imaging (MRI) and baseline clinical/prognostic parameters in multiple myeloma (MM). We compared baseline MM parameters, MRI patterns and localization of focal lesions to the mineralized bone in 206 newly diagnosed MM patients. A high tumour mass (represented by International Staging System stage III) was significantly associated with severe diffuse infiltration (p = 0.015) and a higher number of focal lesions (p = 0.006). Elevated creatinine (p = 0.003), anaemia (p < 0.001) and high LDH (p = 0.001) correlated with severe diffuse infiltration. A salt and pepper diffuse pattern had a favourable prognosis. A higher degree of destruction of mineralized bone (assessed by X-ray or computed tomography) was associated with an increasing number of focal lesions on MRI (p < 0.001). Adverse cytogenetics (del17p/gain1q21/t(4;14)) were associated with diffuse infiltration (p = 0.008). The presence of intraosseous focal lesions exceeding the mineralized bone had a borderline significant impact on prognosis. Diffuse bone marrow infiltration on MRI correlates with adverse cytogenetics, lowered haemoglobin values and high tumour burden in newly diagnosed MM whereas an increasing number of focal lesions correlates with a higher degree of bone destruction. Focal lesions exceeding the cortical bone did not adversely affect the prognosis. (orig.)

  7. Application of self-organizing feature maps to analyze the relationships between ignitable liquids and selected mass spectral ions.

    Science.gov (United States)

    Frisch-Daiello, Jessica L; Williams, Mary R; Waddell, Erin E; Sigman, Michael E

    2014-03-01

    The unsupervised artificial neural networks method of self-organizing feature maps (SOFMs) is applied to spectral data of ignitable liquids to visualize the grouping of similar ignitable liquids with respect to their American Society for Testing and Materials (ASTM) class designations and to determine the ions associated with each group. The spectral data consists of extracted ion spectra (EIS), defined as the time-averaged mass spectrum across the chromatographic profile for select ions, where the selected ions are a subset of ions from Table 2 of the ASTM standard E1618-11. Utilization of the EIS allows for inter-laboratory comparisons without the concern of retention time shifts. The trained SOFM demonstrates clustering of the ignitable liquid samples according to designated ASTM classes. The EIS of select samples designated as miscellaneous or oxygenated as well as ignitable liquid residues from fire debris samples are projected onto the SOFM. The results indicate the similarities and differences between the variables of the newly projected data compared to those of the data used to train the SOFM. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  8. EVALUATION OF ZEBU NELLORE CATTLE BLOOD SAMPLES USING THE CELL-DYN 3500 HEMATOLOGY ANALYZER

    Directory of Open Access Journals (Sweden)

    Alexandre Secorun Borges

    2014-12-01

    Full Text Available The Cell-dyn 3500 is a multiparameter flow cytometer, which may analyze samples from several species performing several simultaneous analyses. It is able to perform white blood cells, red blood cells and platelet counts, besides differential leukocyte counts, packed cell volume and hemoglobin determination. Cell-Dyn 3500 performs total leukocyte count both optically and by impedance. The equipment may choose one or other method, based on the reliability of the results. Erythrocyte and platelet counts are determined by impedance. Leukocyte differentiation is based on an optical principle, using separation in multiangular polarized light. The objective of this study was to compare the results of complete blood count of Zebu Nellore heifers from Celldyn 3500, with those obtained from a semi-automated cell counter (Celm CC 510 and the manual technique. Blood samples were collected from the jugular vein in 5 mL EDTA vacuum tubes from 58 Nellore heifers, at 24 months of age. Samples were processed in parallel in the three different techniques. Results were analyzed using paired t test, Pearson’s correlation and the Bland-Altmann method. There was a strong correlation for all parameters analyzed by Cell-Dyn 3500, manual method and semiautomated cell counter, except for basophils and monocytes counts. These results confirm that this analyzer is reliable for blood samples analysis of zebu cattle.

  9. Portable lactate analyzer for measuring lactate in cerebrospinal fluid (CSF and plasma ? method-comparison evaluations

    Directory of Open Access Journals (Sweden)

    Sérgio Monteiro de Almeida

    2014-07-01

    Full Text Available Increased plasma lactate levels can indicate the presence of metabolic disorders in HIV infected individuals. Objective: To determine whether a portable analyzer is valid for measuring cerebrospinal fluid (CSF and plasma lactate levels in HIV infected individuals. Method: CSF and plasma were collected from 178 subjects. Samples tested by the Accutrend® portable analyzer were compared to those tested by a reference device (SYNCHRON LX® 20. Results: The portable analyzer had in plasma sensitivity of 0.95 and specificity 0.87. For CSF the specificity was 0.95; the sensitivity 0.33; the negative predictive value was 95% and the positive predictive value 33%. Conclusions: These findings support the validity of the portable analyzer in measuring lactate concentrations in CSF that fall within the normal range. The relatively poor positive predictive value indicates that a result above the reference range may represent a “false positive test”, and should be confirmed by the reference device before concluding abnormality.

  10. Defect reconstruction by non-destructive analyzing methods as basis for fracture mechanical evaluation

    International Nuclear Information System (INIS)

    Mueller, W.

    1988-01-01

    This document presents several techniques for the analysis and characterization of defects. The use of sector scan imaging systems is described, together with the Amplitude and Transit-Time Locus Curves (ALOK) searching and analyzing system. Information is also provided on ultrasonic holography and Line Synthetic Aperture Focussing Technique (LSAFT). (TEC)

  11. Defect reconstruction by non-destructive analyzing methods as basis for fracture mechanical evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, W

    1988-12-31

    This document presents several techniques for the analysis and characterization of defects. The use of sector scan imaging systems is described, together with the Amplitude and Transit-Time Locus Curves (ALOK) searching and analyzing system. Information is also provided on ultrasonic holography and Line Synthetic Aperture Focussing Technique (LSAFT). (TEC). 4 refs.

  12. COMBINED MAMMOGRAPHIC AND SONOGRAPHIC EVALUATION OF PALPABLE BREAST MASSES

    Directory of Open Access Journals (Sweden)

    Reena Mathur

    2016-10-01

    Full Text Available BACKGROUND Breast diseases are common in females. In developing countries like India, females are unaware of breast pathologies hence they are detected usually in advanced stages. We have studied 100 patients of palpable breast masses presenting to our department and evaluate the role of combined mammographic and sonographic imaging in patients with palpable abnormalities of the breast, which help in decision making by clinician as to lesion go for biopsy or follow up. MATERIALS AND METHODS The study was conducted at Department of Radiodiagnosis J. L.N. Medical College & Associated Groups of Hospitals, Ajmer. We included women equal to or more than 30 years referred to this centre with palpable abnormalities of breast during a period from March 2015 to August 2016. All these women underwent a combined mammographic and sonographic evaluation of breast. RESULTS 50 (50% of the 100 palpable abnormalities had benign assessment, 30 (60% of the benign lesions were visible both on mammography and sonography; 18 (36% of the 50 benign lesions were mammographically occult and identified at sonographic evaluation. 2 lesion was sonographically occult (4% and visualized on mammography. In 14 (14% of the 100 cases, imaging evaluation resulted in a suspicious assessment and all these lesions underwent biopsy and 4 were diagnosed as having malignancy. 36(36% of the 100 palpable abnormalities had negative imaging assessment finding: of these 14 patients underwent biopsy and all had benign findings. The sensitivity and negative predictive value for combined mammographic and sonographic assessment were 100%; the specificity was 78.26%. CONCLUSION Combined use of mammography and sonography plays an important role in the management of palpable breast lesions. It characterizes the palpable mass lesion, avoids unnecessary interventions in which imaging findings are unequivocally benign. Negative findings on combined mammographic and sonographic imaging have very high

  13. Evaluation of hybrids algorithms for mass detection in digitalized mammograms

    International Nuclear Information System (INIS)

    Cordero, Jose; Garzon Reyes, Johnson

    2011-01-01

    The breast cancer remains being a significant public health problem, the early detection of the lesions can increase the success possibilities of the medical treatments. The mammography is an image modality effective to early diagnosis of abnormalities, where the medical image is obtained of the mammary gland with X-rays of low radiation, this allows detect a tumor or circumscribed mass between two to three years before that it was clinically palpable, and is the only method that until now achieved reducing the mortality by breast cancer. In this paper three hybrids algorithms for circumscribed mass detection on digitalized mammograms are evaluated. In the first stage correspond to a review of the enhancement and segmentation techniques used in the processing of the mammographic images. After a shape filtering was applied to the resulting regions. By mean of a Bayesian filter the survivors regions were processed, where the characteristics vector for the classifier was constructed with few measurements. Later, the implemented algorithms were evaluated by ROC curves, where 40 images were taken for the test, 20 normal images and 20 images with circumscribed lesions. Finally, the advantages and disadvantages in the correct detection of a lesion of every algorithm are discussed.

  14. The use of synthetic spectra to test the preparedness to evaluate and analyze complex gamma spectra

    International Nuclear Information System (INIS)

    Nikkinen, M

    2001-10-01

    This is the report of two exercises that were run under the NKS BOK-1.1 sub-project. In these exercises synthetic gamma spectra were developed to exercise the analysis of difficult spectra typically seen after a severe nuclear accident. The spectra were analyzed twice; first, participants were given short time to give results to resemble an actual emergency preparedness situation, then a longer period of time was allowed to tune the laboratory analysis results for quality assurance purposes. The exercise did prove that it is possible to move measurement data from one laboratory to another if second opinion of the analysis is needed. It was also felt that this kind of exercise would enhance the experience the laboratories have in analyzing accident data. Participants expressed the need for additional exercises of this type, this is inexpensive and an easy way to exercise quick emergency response situations not normally seen in daily laboratory routines. (au)

  15. Evaluation of the hemoglobin A1c-analyzer TOSOH HLC-723 G7.

    Science.gov (United States)

    Gremmels, Heinz-Detlef; Richter, Anja; Watzke, Ivonne

    2003-01-01

    The TOSOH HLC-723 G7 is a compact analyzer designed for the measurement of HbA1c under routine laboratory conditions. The analyzer has an automatic blood tube supply and positive sample identification. Samples are transported automatically via racks in a continuous-load mode, cap piercing is optional. Tests devoted to the assessment of reproducibility and accuracy of analytical results indicated that over a test period of 17 days, the intra-assay variation (CV) was 1.79%, and the inter-assay variation 2.60%, respectively. A comparison with the predecessor model G5 showed a very good correlation (r = 0.997, y = 1.0041x - 0.00172; n = 149). The presence of high triglyceride, bilirubin or urea concentrations in patient samples did not influence the analytical precision. The labile HbA1c fraction (L-A1c) is clearly separated during chromatography and thus does not compromise HbA1c analysis. With a protocol of 1.2 minutes, the TOSOH G7 is a very fast analyzer, designed for laboratories with a high throughput of samples.

  16. Taking Seriously Ingroup Self-Evaluation, Meta-Prejudice, and Prejudice in Analyzing Interreligious Relations.

    Science.gov (United States)

    Putra, Idhamsyah Eka

    2016-07-18

    The present study aims to understand the conditions where prejudice can be predicted by ingroup and outgroup meta-prejudice. The data collecting was disseminated toward Muslim and Christian participants (N = 362) living in Maumere, Flores Island, Indonesia. In Flores, Christianity is the largest religion and Islam is the second. Across two samples, the effects of ingroup and outgroup meta-prejudice on prejudice were found to be moderated by ingroup self-evaluation. It shows that at high level (but not low) of positive ingroup self-evaluation, ingroup and outgroup meta-prejudice were found to predict prejudice. The results suggest that it is important to consider how group members evaluate their own group and how group members think what others are thinking, in the study pertaining to intergroup relations.

  17. Toxicity and Detoxification Effects of Herbal Caowu via Ultra Performance Liquid Chromatography/Mass Spectrometry Metabolomics Analyzed using Pattern Recognition Method

    Science.gov (United States)

    Yan, Yan; Zhang, Aihua; Dong, Hui; Yan, Guangli; Sun, Hui; Wu, Xiuhong; Han, Ying; Wang, Xijun

    2017-01-01

    Background: Caowu (Radix Aconiti kusnezoffii, CW), the root of Aconitum kusnezoffii Reichb., has widely used clinically in rheumatic arthritis, painful joints, and tumors for thousands of years. However, the toxicity of heart and central nervous system induced by CW still limited the application. Materials and Methods: Metabolomics was performed to identify the sensitive and reliable biomarkers and to characterize the phenotypically biochemical perturbations and potential mechanisms of CW-induced toxicity, and the detoxification by combinatorial intervention of CW with Gancao (Radix Glycyrrhizae) (CG), Baishao (Radix Paeoniae Alba) (CB), and Renshen (Radix Ginseng) (CR) was also analyzed by pattern recognition methods. Results: As a result, the metabolites were characterized and responsible for pentose and glucuronate interconversions, tryptophan metabolism, amino sugar and nucleotide sugar metabolism, taurine and hypotaurine metabolism, fructose and mannose metabolism, and starch and sucrose metabolism, six networks of which were the same to the metabolic pathways of Chuanwu (Radix Aconiti, CHW) group. The ascorbate and aldarate metabolism was also characterized by CW group. The urinary metabolomics also revealed CW-induced serious toxicity to heart and liver. Thirteen significant metabolites were identified and had validated as phenotypic toxicity biomarkers of CW, five biomarkers of which were commonly owned in Aconitum. The changes of toxicity metabolites obtained from combinatorial intervention of CG, CB, and CR also were analyzed to investigate the regulation degree of toxicity biomarkers adjusted by different combinatorial interventions at 6th month. Conclusion: Metabolomics analyses coupled with pattern recognition methods in the evaluation of drug toxicity and finding detoxification methods were highlighted in this work. SUMMARY Metabolomics was performed to characterize the biochemical potential mechanisms of Caowu toxicityThirteen significant metabolites

  18. Multichannel analyzer and spectrum evaluation program for a PDP-8/I computer

    International Nuclear Information System (INIS)

    German, U.

    1976-01-01

    The present report is intended to give descriptions of program functions and performances for a small computer used as multichannel analyzer; this has the advantage of flexibility and simple alteration of program parts for various experiments. To the common part of data acquisition and handling was added a calculation section which enables spectrum analysis; peaks are identified and their characteristics are printed, greatly simplifying the work of the analyst. Parameters for the detection efficiency curve are included in the program and thus absolute gamma-ray measurement can be performed on-line. The operation and use of the program are explained. (B.G.)

  19. Evaluation of a Portable Automated Serum Chemistry Analyzer for Field Assessment of Harlequin Ducks, Histrionicus histrionicus

    Directory of Open Access Journals (Sweden)

    Michael K. Stoskopf

    2010-01-01

    ; quartiles 2.4 and 3.0 mmol/L. Serum potassium values were too low for quantitation by the traditional laboratory. Changes in several serum chemistry values following a three-day storm during the study support the value of on site evaluation of serum potassium to identify presurgical patients with increased anesthetic risk.

  20. Analyzing and Evaluating the 1:1 Learning Model: What Would Dewey Do?

    Science.gov (United States)

    Boulden, Danielle Cadieux

    2017-01-01

    One-to-one computing models, in which every student in a classroom is provided access to a digital device for instruction, have gained traction and popularity as an instructional model across United States classrooms and around the globe. This paper explores and evaluates these 1:1 computing models in K-12 learning environments through the lens of…

  1. Isotope ratio mass spectrometry (IRMS) versus laser-assisted ratio analyzer (LARA): a comparative study using two doses of.

    Science.gov (United States)

    Savarino, V; Landi, F; Dulbecco, P; Ricci, C; Tessieri, L; Biagini, R; Gatta, L; Miglioli, M; Celle, G; Vaira, D

    2000-11-01

    (P = NS). The LARA system is a valid alternative to IRMS in the diagnosis of H. pylori infection. Both machines provide highly reliable results after 30 min, so that the 60 min sample can be avoided. The dose of 75 mg + citric acid suffices to ensure an accurate UBT. The test performed with both devices and [13C]urea dosages is very effective also for posttherapy evaluation of H. pylori status.

  2. The Ame2012 atomic mass evaluation. Pt. 1. Evaluation of input data, adjustment procedures

    International Nuclear Information System (INIS)

    Audi, G; Wang, M.; Wapstra, A.H.; Kondev, F.G.; MacCormick, M.; Xu, X.; Pfeiffer, B.

    2012-01-01

    This paper is the first of two articles (Part I and Part II) that presents the results of the new atomic mass evaluation, Ame2012. It includes complete information on the experimental input data (including not used and rejected ones), as well as details on the evaluation procedures used to derive the tables with recommended values given in the second part. This article describes the evaluation philosophy and procedures that were implemented in the selection of specific nuclear reaction, decay and mass-spectrometer results. These input values were entered in the least-squares adjustment procedure for determining the best values for the atomic masses and their uncertainties. Calculation procedures and particularities of the AME are then described. All accepted and rejected data, including outweighed ones, are presented in a tabular format and compared with the adjusted values (obtained using the adjustment procedure). Differences with the previous Ame2003 evaluation are also discussed and specific information is presented for several cases that may be of interest to various AME users. The second Ame2012 article, the last one in this issue, gives a table with recommended values of atomic masses, as well as tables and graphs of derived quantities, along with the list of references used in both this Ame2012 evaluation and the Nubase2012 one (the first paper in this issue). (authors)

  3. The evaluation of the feasibility about prostate SBRT by analyzing interfraction errors of internal organs

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Soon Gi; Son, Sang Joon; Moon, Joon Gi; KIm, Bo Kyum; Lee, Je Hee [Dept. of Radiation Oncology, Seoul National University Hospital, Seoul (Korea, Republic of)

    2016-12-15

    To figure out if the treatment plan for rectum, bladder and prostate that have a lot of interfraction errors satisfies dosimetric limits without adaptive plan by analyzing MR image. This study was based on 5 prostate cancer patients who had IMRT(total dose: 70 Gy) Using ViewRay MRIdian System(ViewRay, ViewRay Inc., Cleveland, OH, USA) The treatment plans were made on the same CT images to compare with the plan quality according to adaptive plan, and the Eclipse(Ver 10.0.42, Varian, USA) was used. After registrate the 5 treatment MR images to the CT images for treatment plan to analyze the interfraction changes of organ, we measured the dose volume histogram and the changes of the absolute volume for each organ by applying the first treatment plan to each image. Over 5 fractions, the total dose for PTV was V{sub 36.25} Gy ≧ 95%. To confirm that the prescription dose satisfies the SBRT dose limit for prostate, we measured V{sub 100%} , V{sub 95%}, V{sub 90%} for CTV and V{sub 100%}, V{sub 90%}, V{sub 80%}, V{sub 50%} of rectum and bladder. All dose average value of CTV, rectum and bladder satisfied dose limit, but there was a case that exceeded dose limit more than one after analyzing the each image of treatment. After measuring the changes of absolute volume comparing the MR image of the first treatment plan with the one of the interfraction treatment, the difference values were maximum 1.72 times at rectum and maximum 2.0 times at bladder. In case of rectum, the expected values were planned under the dose limit, on average, V{sub 100%}=0.32%, V{sub 90%}=3.33%, V{sub 80%}=7.71%, V{sub 50%}=23.55% in the first treatment plan. In case of rectum, the average of absolute volume in first plan was 117.9 cc. However, the average of really treated volume was 79.2 cc. In case of CTV, the 100% prescription dose area didn't satisfy even though the margin for PTV was 5 mm because of the variation of rectal and bladder volume. There was no case that the value from average

  4. The evaluation of the feasibility about prostate SBRT by analyzing interfraction errors of internal organs

    International Nuclear Information System (INIS)

    Hong, Soon Gi; Son, Sang Joon; Moon, Joon Gi; KIm, Bo Kyum; Lee, Je Hee

    2016-01-01

    To figure out if the treatment plan for rectum, bladder and prostate that have a lot of interfraction errors satisfies dosimetric limits without adaptive plan by analyzing MR image. This study was based on 5 prostate cancer patients who had IMRT(total dose: 70 Gy) Using ViewRay MRIdian System(ViewRay, ViewRay Inc., Cleveland, OH, USA) The treatment plans were made on the same CT images to compare with the plan quality according to adaptive plan, and the Eclipse(Ver 10.0.42, Varian, USA) was used. After registrate the 5 treatment MR images to the CT images for treatment plan to analyze the interfraction changes of organ, we measured the dose volume histogram and the changes of the absolute volume for each organ by applying the first treatment plan to each image. Over 5 fractions, the total dose for PTV was V_3_6_._2_5 Gy ≧ 95%. To confirm that the prescription dose satisfies the SBRT dose limit for prostate, we measured V_1_0_0_% , V_9_5_%, V_9_0_% for CTV and V_1_0_0_%, V_9_0_%, V_8_0_%, V_5_0_% of rectum and bladder. All dose average value of CTV, rectum and bladder satisfied dose limit, but there was a case that exceeded dose limit more than one after analyzing the each image of treatment. After measuring the changes of absolute volume comparing the MR image of the first treatment plan with the one of the interfraction treatment, the difference values were maximum 1.72 times at rectum and maximum 2.0 times at bladder. In case of rectum, the expected values were planned under the dose limit, on average, V_1_0_0_%=0.32%, V_9_0_%=3.33%, V_8_0_%=7.71%, V_5_0_%=23.55% in the first treatment plan. In case of rectum, the average of absolute volume in first plan was 117.9 cc. However, the average of really treated volume was 79.2 cc. In case of CTV, the 100% prescription dose area didn't satisfy even though the margin for PTV was 5 mm because of the variation of rectal and bladder volume. There was no case that the value from average of five fractions is over the

  5. Evaluation of Colorimetric Assays for Analyzing Reductively Methylated Proteins: Biases and Mechanistic Insights

    OpenAIRE

    Brady, Pamlea N.; Macnaughtan, Megan A.

    2015-01-01

    Colorimetric protein assays, such as the Coomassie blue G-250 dye-binding (Bradford) and bicinchoninic acid (BCA) assays, are commonly used to quantify protein concentration. The accuracy of these assays depends on the amino acid composition. Because of the extensive use of reductive methylation in the study of proteins and the importance of biological methylation, it is necessary to evaluate the impact of lysyl methylation on the Bradford and BCA assays. Unmodified and reductively methylated...

  6. Digital video timing analyzer for the evaluation of PC-based real-time simulation systems

    Science.gov (United States)

    Jones, Shawn R.; Crosby, Jay L.; Terry, John E., Jr.

    2009-05-01

    Due to the rapid acceleration in technology and the drop in costs, the use of commercial off-the-shelf (COTS) PC-based hardware and software components for digital and hardware-in-the-loop (HWIL) simulations has increased. However, the increase in PC-based components creates new challenges for HWIL test facilities such as cost-effective hardware and software selection, system configuration and integration, performance testing, and simulation verification/validation. This paper will discuss how the Digital Video Timing Analyzer (DiViTA) installed in the Aviation and Missile Research, Development and Engineering Center (AMRDEC) provides quantitative characterization data for PC-based real-time scene generation systems. An overview of the DiViTA is provided followed by details on measurement techniques, applications, and real-world examples of system benefits.

  7. Evaluating the Efficacy of GLUT Inhibitors Using a Seahorse Extracellular Flux Analyzer.

    Science.gov (United States)

    Wei, Changyong; Heitmeier, Monique; Hruz, Paul W; Shanmugam, Mala

    2018-01-01

    Glucose is metabolized through anaerobic glycolysis and aerobic oxidative phosphorylation (OXPHOS). Perturbing glucose uptake and its subsequent metabolism can alter both glycolytic and OXPHOS pathways and consequently lactate and/or oxygen consumption. Production and secretion of lactate, as a consequence of glycolysis, leads to acidification of the extracellular medium. Molecular oxygen is the final electron acceptor in the electron transport chain, facilitating oxidative phosphorylation of ADP to ATP. The alterations in extracellular acidification and/or oxygen consumption can thus be used as indirect readouts of glucose metabolism and assessing the impact of inhibiting glucose transport through specific glucose transporters (GLUTs). The Seahorse bioenergetics analyzer can measure both the oxygen consumption rate (OCR) and extracellular acidification rate (ECAR). The proposed methodology affords a robust, high-throughput method to screen for GLUT inhibition in cells engineered to express specific GLUTs, providing live cell read-outs upon GLUT inhibition.

  8. Organic environments on Saturn's moon, Titan: simulating chemical reactions and analyzing products by FT-ICR and ion-trap mass spectrometry.

    Science.gov (United States)

    Somogyi, Arpad; Oh, Chu-Ha; Smith, Mark A; Lunine, Jonathan I

    2005-06-01

    Laboratory simulations have been carried out to model chemical reactions that possibly take place in the stratosphere of Saturn's moon, Titan. The aerosol products of these reactions (tholin samples) have been systematically analyzed by mass spectrometry using electrospray ionization (ESI) and laser desorption (LD). A wide variety of ions with a general formula C(x)H(y)N(z) detected by ultrahigh resolution and accurate mass measurements in a Fourier transform/ion cyclotron resonance (FT-ICR) cell reflect the complexity of these polymeric products, both in chemical compositions and isomeric distributions. As a common feature, however, tandem mass spectral (MS/MS) data and H/D exchange products in the solution phase support the presence of amino and nitrile functionalities in these (highly unsaturated) "tholin" compounds. The present work demonstrates that ESI-MS coupled with FT-ICR is a suitable and "intact" method to analyze tholin components formed under anaerobic conditions; only species with C(x)H(y)N(z) are detected for freshly prepared and harvested samples. However, when intentionally exposed to water, oxygen-containing compounds are unambiguously detected.

  9. The AME2003 atomic mass evaluation (I). Evaluation of input data, adjustment procedures

    International Nuclear Information System (INIS)

    Wapstra, A.H.; Audi, G.; Thibault, C.

    2003-01-01

    This paper is the first of two parts presenting the result of a new evaluation of atomic masses (AME2003). In this first part we give full information on the used and rejected input data and on the procedures used in deriving the tables in the second part. We first describe the philosophy and procedures used in selecting nuclear-reaction, decay, and mass spectrometric results as input values in a least-squares evaluation of best values for atomic masses. The calculation procedures and particularities of the AME are then described. All accepted data, and rejected ones with a reported precision still of interest, are presented in a table and compared there with the adjusted values. The differences with the earlier evaluation are briefly discussed and information is given of interest for the users of this AME. The second paper for the AME2003, last in this issue, gives a table of atomic masses, tables and graphs of derived quantities, and the list of references used in both this evaluation and the NUBASE2003 table (first paper in this issue). AMDC: http://csnwww.in2p3.fr/AMDC/

  10. Development and Evaluation of a Reverse-Entry Ion Source Orbitrap Mass Spectrometer

    Science.gov (United States)

    Poltash, Michael L.; McCabe, Jacob W.; Patrick, John W.; Laganowsky, Arthur; Russell, David H.

    2018-05-01

    As a step towards development of a high-resolution ion mobility mass spectrometer using the orbitrap mass analyzer platform, we describe herein a novel reverse-entry ion source (REIS) coupled to the higher-energy C-trap dissociation (HCD) cell of an orbitrap mass spectrometer with extended mass range. Development of the REIS is a first step in the development of a drift tube ion mobility-orbitrap MS. The REIS approach retains the functionality of the commercial instrument ion source which permits the uninterrupted use of the instrument during development as well as performance comparisons between the two ion sources. Ubiquitin (8.5 kDa) and lipid binding to the ammonia transport channel (AmtB, 126 kDa) protein complex were used as model soluble and membrane proteins, respectively, to evaluate the performance of the REIS instrument. Mass resolution obtained with the REIS is comparable to that obtained using the commercial ion source. The charge state distributions for ubiquitin and AmtB obtained on the REIS are in agreement with previous studies which suggests that the REIS-orbitrap EMR retains native structure in the gas phase.

  11. Atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry of friction modifier additives analyzed directly from base oil solutions.

    Science.gov (United States)

    Widder, Lukas; Brennerb, Josef; Huttera, Herbert

    2014-01-01

    To develop new products and to apply measures of quality control quick and simple accessibility of additive composition in automo- tive lubrication is important. The aim of this study was to investigate the possibility of analyzing organic friction modifier additives by means of atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry [AP-MALDI-MS] from lubricant solu- tions without the use of additional separation techniques. Analyses of selected friction modifier ethoxylated tallow amines and oleic acid amide were compared using two ionization methods, positive-ion electrospray ionization (ESI) and AP-MALDI, using a LTQ Orbitrap mass spectrometer. Pure additives were characterized from solvent solutions, as well as from synthetic and mineral base oil mixtures. Detected ions of pure additive samples consisted mainly of [M + H]+, but also alkaLi metal adducts [M + Na]+ and [M + K]+ could be seen. Characterizations of blends of both friction modifiers from the base oil mixtures were carried out as well and showed significant inten- sities for several additive peaks. Thus, this work shows a method to directly analyze friction modifier additives used in the automotive industry from an oil blend via the use of AP-MALDI without any further separation steps. The method presented will further simplify the acquisition of data on lubricant composition and additives. Furthermore, it allows the perspective of analyzing additive reaction products directly from formulated oil blends.

  12. Evaluation of statistical distributions to analyze the pollution of Cd and Pb in urban runoff.

    Science.gov (United States)

    Toranjian, Amin; Marofi, Safar

    2017-05-01

    Heavy metal pollution in urban runoff causes severe environmental damage. Identification of these pollutants and their statistical analysis is necessary to provide management guidelines. In this study, 45 continuous probability distribution functions were selected to fit the Cd and Pb data in the runoff events of an urban area during October 2014-May 2015. The sampling was conducted from the outlet of the city basin during seven precipitation events. For evaluation and ranking of the functions, we used the goodness of fit Kolmogorov-Smirnov and Anderson-Darling tests. The results of Cd analysis showed that Hyperbolic Secant, Wakeby and Log-Pearson 3 are suitable for frequency analysis of the event mean concentration (EMC), the instantaneous concentration series (ICS) and instantaneous concentration of each event (ICEE), respectively. In addition, the LP3, Wakeby and Generalized Extreme Value functions were chosen for the EMC, ICS and ICEE related to Pb contamination.

  13. Evaluation of Rutting Performance of Asphalt Mixture with Driving Wheel Pavement Analyzer

    Directory of Open Access Journals (Sweden)

    Xu Cai

    2017-01-01

    Full Text Available Rutting is common pavement distress, which leads to lower riding comfort for road users and high maintenance costs. One of the commonly used tests is the simulation test with wheel tracking devices. Here, a new rutting test system has been developed based on the “Driving Wheel Pavement Analyzer” (DWPA to evaluate the rutting performance of asphalt mixtures. This study conducted three types of rutting tests to validate feasibility, reliability, and accuracy of DWPA test. The results indicated that the DWPA test provided more information on ruts and enabled us to distinguish the performance of materials. The CDWPA index is better suited to reflect the rutting resistance of the material, which is highly correlated to the APA rutting index and the rutting test index of China according to the grey relational analysis results.

  14. New approach to analyzing and evaluating cross sections for partial photoneutron reactions

    International Nuclear Information System (INIS)

    Varlamov, V. V.; Ishkhanov, B. S.; Orlin, V. N.

    2012-01-01

    The presence of substantial systematic discrepancies between the results of different experiments devoted to determining cross sections for partial photoneutron reactions—first of all, (γ, n), (γ, 2n), and (γ, 3n) reactions—is a strong motivation for studying the reliability and authenticity of these data and for developing methods for taking into account and removing the discrepancies in question. In order to solve the first problem, we introduce objective absolute criteria involving transitional photoneutron-multiplicity functions F 1 , F 2 , F 3 , …; by definition, their values cannot exceed 1.0, 0.5, 0.33, …, respectively. With the aim of solving the second problem, we propose a new experimental-theoretical approach. In this approach, reaction cross sections are evaluated by simultaneously employing experimental data on the cross section for the total photoneutron yield, σ expt (γ, xn) = σ expt (γ, n) + 2σ expt (γ, 2n) + 3σ expt (γ, 3n) + …, which are free from drawbacks plaguing experimental methods for sorting neutrons in multiplicity, and the results obtained by calculating the functions F theor 1 , F theor 2 , F theor 3 , … on the basis of the modern model of photonuclear reactions. The reliability and authenticity of data on the cross sections for (γ, n), (γ, 2n), and (γ, 3n) partial reactions—σ eval (γ, in) = F i theor σ expt (γ, xn)—were evaluated for the 90 Zr, 115 In, 112,114,116,117,118,119,120,122,124 Sn, 159 Tb, and 197 Au nuclei.

  15. Evaluation of Reference Genes to Analyze Gene Expression in Silverside Odontesthes humensis Under Different Environmental Conditions

    Directory of Open Access Journals (Sweden)

    Tony L. R. Silveira

    2018-03-01

    Full Text Available Some mammalian reference genes, which are widely used to normalize the qRT-PCR, could not be used for this purpose due to its high expression variation. The normalization with false reference genes leads to misinterpretation of results. The silversides (Odontesthes spp. has been used as models for evolutionary, osmoregulatory and environmental pollution studies but, up to now, there are no studies about reference genes in any Odontesthes species. Furthermore, many studies on silversides have used reference genes without previous validations. Thus, present study aimed to was to clone and sequence potential reference genes, thereby identifying the best ones in Odontesthes humensis considering different tissues, ages and conditions. For this purpose, animals belonging to three ages (adults, juveniles, and immature were exposed to control, Roundup®, and seawater treatments for 24 h. Blood samples were subjected to flow-cytometry and other collected tissues to RNA extraction; cDNA synthesis; molecular cloning; DNA sequencing; and qRT-PCR. The candidate genes tested included 18s, actb, ef1a, eif3g, gapdh, h3a, atp1a, and tuba. Gene expression results were analyzed using five algorithms that ranked the candidate genes. The flow-cytometry data showed that the environmental challenges could trigger a systemic response in the treated fish. Even during this systemic physiological disorder, the consensus analysis of gene expression revealed h3a to be the most stable gene expression when only the treatments were considered. On the other hand, tuba was the least stable gene in the control and gapdh was the least stable in both Roundup® and seawater groups. In conclusion, the consensus analyses of different tissues, ages, and treatments groups revealed that h3a is the most stable gene whereas gapdh and tuba are the least stable genes, even being considered two constitutive genes.

  16. Evaluation of ultrasound in the diagnosis of parotid gland masses

    Directory of Open Access Journals (Sweden)

    Parotid gland

    1999-08-01

    Full Text Available In order to evaluate accuracy and usefulness of sonography and choose it as preliminary investigation method in pathologic processes of parotid gland, 50 patients were studied in duration of 16 months. The lesions were evaluated with ultrasound and sonographic images were obtained before surgery and then were compared with pathologic results after surgery. All lesions were detected with sonography. This method could differentiate intraglandular from extraglandular lesions with accuracy of 100%. Except one case of lipomatosis which was hyperechoic, all other lesions of parotid gland were hypoechoic. All lesions with sharp and well-defined borders were benign whereas malignant processes had ill-defined borders. The results obtained show that sonography is a reliable diagnostic method to differentiate benign from malignant lesions and it has a high diagnostic value to detect warthin's tumor, plemorphic adenoma, Sjogren's syndrome and lipomatosis. Presence of calcification in a parotid mass of young patient with high probabye is related to cavernous hemangioma.

  17. Evaluation of the intraocular pressure measured with the ocular response analyzer.

    Science.gov (United States)

    Ogbuehi, Kelechi C; Almubrad, Turki M

    2010-07-01

    Comparison of the magnitude and repeatability of the intraocular pressure (IOP) measured with the Ocular Response Analyzer (ORA) to that measured with the Goldmann tonometer. Two sets of IOP measurements were made, for 89 eyes of eighty-nine subjects, approximately 1-week apart. Goldmann tonometry was performed subsequent to non-contact tonometry, in which the order of measurement was randomized between the ORA and the Topcon CT80 non-contact tonometer (CT80). Each method was assessed twice for intrasession repeatability. The limits of agreement between each non-contact pressure and that measured with the Goldmann tonometer were assessed once per session. The level of statistical significance was 0.05. The mean differences between the ORA-corneal compensated, Goldmann-correlated, and CT80-IOP (ORA-IOPcc; ORA-IOPg and CT80-IOP) versus the Goldmann IOP were -0.3 +/- 2.7 mmHg (mean +/- SD), -0.3 +/- 2.2 mmHg and -0.3 +/- 2.1 mmHg, respectively for session 1 and 0.3 +/- 3.0 mmHg, 0.2 +/- 2.2 mmHg, and -0.5 +/- 2.2 mmHg, respectively, for session 2. The repeatability coefficients were +/- 5.3 mmHg, +/- 4.2 mmHg, +/- 2.5 mmHg, and +/- 1.9 mmHg, respectively for ORA-IOPcc, ORA-IOPg, CT80-IOP, and Goldmann IOP in session 1 and +/- 3.8 mmHg, +/- 3.6 mmHg, +/- 1.6 mmHg, and +/- 1.9 mmHg, respectively for session 2. The repeatability indices for the ORA were poorer than those with the Goldmann tonometer and the CT80 in both sessions. However, the average IOP measured with the ORA did not vary significantly from those measured with the other two tonometers in either session. The ORA provides valid, repeatable measures of IOP.

  18. Analyzing Movements Development and Evaluation of the Body Awareness Scale Movement Quality (BAS MQ).

    Science.gov (United States)

    Sundén, A; Ekdahl, C; Horstman, V; Gyllensten, A L

    2016-06-01

    Limitations in everyday movements, physical activities are/or pain are the main reasons for seeking help from a physiotherapist. The purpose of this study was to investigate the psychometric properties of the Body Awareness Scale Movement Quality (BAS MQ) focusing on factor structure, validity and reliability and to explore whether BAS MQ could discriminate between healthy individuals and patients. BAS MQ assesses both limitations and resources concerning functional ability and quality of movements. The total sample in the study (n = 172) consisted of individuals with hip osteoarthritis (OA) (n = 132), individuals with psychiatric disorders (n = 33) and healthy individuals (n = 7). A factor analysis of the BAS MQ was performed for the total group. Inter-rater reliability was tested in a group of individuals with hip OA (n = 24). Concurrent validity was tested in a group of individuals with hip OA (n = 89). The Medical Outcomes Study 36-Item Short-Form Health Survey (SF-36), the 6-Minute Walk Test (6MWT) and the Hip Osteoarthritis Outcome Score (HOOS) were chosen in the validation process. The factor analysis revealed three factors that together explained 60.8% of the total variance of BAS MQ. The inter-rater reliability was considered good or very good with a kappa value of 0.61. Significant correlations between BAS MQ and SF-36, HOOS and 6MWT in the subjects with hip OA confirmed the validity. The BAS MQ was able to discriminate between healthy individuals and individuals with physical and psychiatric limitations. Results of the study revealed that BAS MQ has a satisfactory factor structure. The inter-rater reliability and validity were acceptable in a group of individuals with hip OA. BAS MQ could be a useful assessment tool for physiotherapists when evaluating the quality of everyday movements in different patient groups. Copyright © 2014 John Wiley & Sons, Ltd. Copyright © 2014 John Wiley & Sons, Ltd.

  19. EVALUATION OF RIGHT ILIAC FOSSA MASS-A RETROSPECTIVE STUDY

    OpenAIRE

    Raja Billy Graham; Vijayabhasker

    2016-01-01

    Mass in right iliac fossa is one of the common clinical surgical entity with varied etiologies, involving intra peritoneal organs like vermiform appendix, caucus, ileum, retroperitoneal structures like kidneys, blood vessels etc., and abdominal wall masses like desmoids tumor. To know the etiology and the various pattern of presentation of right iliac fossa mass in our institution a retrospective study was designed including all adult patients diagnosed to have a mass in right ili...

  20. Evaluation of the mass measles vaccination campaign in Guangdong Province, China.

    Science.gov (United States)

    Peng, Zhi Qiang; Chen, Wei Shi; He, Qun; Peng, Guo Wen; Wu, Cheng Gang; Xu, Ning; Zhao, Zhan Jie; Shu, Jun; Tan, Qiu; Zheng, Hui Zhen; Lin, Li Feng; Deng, Hui Hong; Lin, Jin Yan; Zhang, Yong Hui

    2012-02-01

    To evaluate the mass measles vaccination campaign of 2009 in Guangdong Province, China. Data on the campaign implementation, measles surveillance, and serological surveillance were reviewed and analyzed by statistical methods. Rapid coverage surveys showed that 98.09% of children were vaccinated during the campaign. The coverage of migrant children increased significantly from 67.10% to 97.32% (pvaccinated during the campaign. Flyers, notices of information from doctors, and television programs were the best methods to inform parents of the campaign. Awareness of the campaign by residents increased significantly from 91.86% to 97.10% (pvaccination campaign approach for controlling measles in a developing region like Guangdong Province with a vast migrant population has proved effective. Comprehensive mobilization, communication with the mass media, and support from government departments were critical to the success of the campaign. Copyright © 2011 International Society for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  1. Mass

    International Nuclear Information System (INIS)

    Quigg, Chris

    2007-01-01

    In the classical physics we inherited from Isaac Newton, mass does not arise, it simply is. The mass of a classical object is the sum of the masses of its parts. Albert Einstein showed that the mass of a body is a measure of its energy content, inviting us to consider the origins of mass. The protons we accelerate at Fermilab are prime examples of Einsteinian matter: nearly all of their mass arises from stored energy. Missing mass led to the discovery of the noble gases, and a new form of missing mass leads us to the notion of dark matter. Starting with a brief guided tour of the meanings of mass, the colloquium will explore the multiple origins of mass. We will see how far we have come toward understanding mass, and survey the issues that guide our research today.

  2. Comparison and clinical utility evaluation of four multiple allergen simultaneous tests including two newly introduced fully automated analyzers

    Directory of Open Access Journals (Sweden)

    John Hoon Rim

    2016-04-01

    Full Text Available Background: We compared the diagnostic performances of two newly introduced fully automated multiple allergen simultaneous tests (MAST analyzers with two conventional MAST assays. Methods: The serum samples from a total of 53 and 104 patients were tested for food panels and inhalant panels, respectively, in four analyzers including AdvanSure AlloScreen (LG Life Science, Korea, AdvanSure Allostation Smart II (LG Life Science, PROTIA Allergy-Q (ProteomeTech, Korea, and RIDA Allergy Screen (R-Biopharm, Germany. We compared not only the total agreement percentages but also positive propensities among four analyzers. Results: Evaluation of AdvanSure Allostation Smart II as upgraded version of AdvanSure AlloScreen revealed good concordance with total agreement percentages of 93.0% and 92.2% in food and inhalant panel, respectively. Comparisons of AdvanSure Allostation Smart II or PROTIA Allergy-Q with RIDA Allergy Screen also showed good concordance performance with positive propensities of two new analyzers for common allergens (Dermatophagoides farina and Dermatophagoides pteronyssinus. The changes of cut-off level resulted in various total agreement percentage fluctuations among allergens by different analyzers, although current cut-off level of class 2 appeared to be generally suitable. Conclusions: AdvanSure Allostation Smart II and PROTIA Allergy-Q presented favorable agreement performances with RIDA Allergy Screen, although positive propensities were noticed in common allergens. Keywords: Multiple allergen simultaneous test, Automated analyzer

  3. Performance of the Linear Ion Trap Mass Spectrometer for the Mars Organic Molecule Analyzer (MOMA) Investigation on the 2018 Exomars Rover

    Science.gov (United States)

    Arevalo, Ricardo, Jr.; Brinckerhoff, William B.; Pinnick, Veronica T.; van Amerom, Friso H. W.; Danell, Ryan M.; Li, Xiang; Getty, Stephanie; Hovmand, Lars; Atanassova, Martina; Mahaffy, Paul R.; hide

    2014-01-01

    The 2018 ExoMars rover mission includes the Mars Organic Molecule Analyzer (MOMA) investigation. MOMA will examine the chemical composition of samples acquired from depths of up to two meters below the martian surface, where organics may be protected from degradation derived from cosmic radiation and/or oxidative chemical reactions. When combined with the complement of instruments in the rover's Pasteur Payload, MOMA has the potential to reveal the presence of a wide range of organics preserved in a variety of mineralogical environments, and to begin to understand the structural character and potential origin of those compounds. The MOMA investigation is led by the Max Planck Institute for Solar System Research (MPS) with the mass spectrometer subsystem provided by NASA GSFC. MOMA's linear ion trap mass spectrometer (ITMS) is designed to analyze molecular composition of: (i) gas evolved from pyrolyzed powder samples and separated in a gas chromatograph; and, (ii) ions directly desorbed from crushed solid samples at Mars ambient pressure, as enabled by a pulsed UV laser system, fast-actuating aperture valve and capillary ion inlet. Breadboard ITMS and associated electronics have been advanced to high end-to-end fidelity in preparation for flight hardware delivery to Germany in 2015.

  4. Evaluation of Mass Housing at the Pre-Design Stage

    Directory of Open Access Journals (Sweden)

    Kozan UZUNOĞLU

    2014-09-01

    Full Text Available Throughout history, housing has been a central problem in the lives of human beings. Housing, which includes shelter for family and functional volumes that meet social needs, used to be built specifically for the family. The concept of “Mass Housing” entered the field of architecture as a result of the industrial revolution, when lavish Renaissance housing gradually turned into housing for workers. Today, the demand for housing cannot keep up with fast-growing populations. Besides the quantitative problems of housing production, there is the ever- growing problem of quality, the solution to which lies with designer architects. On this issue of quality, Post Occupation Evaluation (POE studies, conducted to provide data for upcoming designs, and certificate evaluations like LEED and BREEAM, aimed at measuring energy performance effectiveness of new buildings, mostly involve measurements of usage of the building envelope, environmental relations, facilities and usage of natural resources. None prioritize the form and function issues of spatial usage in architectural designs. This study proposes a method that enables spatial and functional measurement and assessment at the project stage. The suggested spatial performance measurement–assessment system has three stages. In the first stage, the standards and usage criteria to be used as reference in the assessment are defined. The second stage suggests using the SAR analysis approach, and the third stage is about conducting “Spatial Performance Assessment”. Here, the common denominator of “User System” and “Building System”, which shares characteristic design criteria “Form, Function,Construction” is established and by this way, testing and assessing the subject of study becomes possible. With these assessments, by providing digitalization of spatial performance with proportional values, it is believed that a database for the provision of statistical information may be established.

  5. Performance of the linear ion trap Orbitrap mass analyzer for qualitative and quantitative analysis of drugs of abuse and relevant metabolites in sewage water.

    Science.gov (United States)

    Bijlsma, Lubertus; Emke, Erik; Hernández, Félix; de Voogt, Pim

    2013-03-20

    This work illustrates the potential of liquid chromatography coupled to a hybrid linear ion trap Fourier Transform Orbitrap mass spectrometer for the simultaneous identification and quantification of 24 drugs of abuse and relevant metabolites in sewage water. The developed methodology consisted of automatic solid-phase extraction using Oasis HLB cartridges, chromatographic separation of the targeted drugs, full-scan accurate mass data acquisition under positive electrospray ionization mode over an m/z range of 50-600Da at a resolution of 30,000 FWHM and simultaneous MS(n) measurements to obtain information of fragment ions generated in the linear ion trap. Accurate mass of the protonated molecule, together with at least one nominal mass product ion and retention time allowed the confident identification of the compounds detected in these complex matrices. In addition to the highly reliable qualitative analysis, Orbitrap analyzer also proved to have satisfactory potential for quantification at sub-ppb analyte levels, a possibility that has been very little explored in the literature until now. The limits of quantification ranged from 4 to 68ngL(-1) in influent sewage water, and from 2 to 35ngL(-1) in effluent, with the exception of MDA, morphine and THC that presented higher values as a consequence of the high ionization suppression in this type of samples. Satisfactory recoveries (70-120%) and precision (abuse could be identified and quantified, mainly MDMA, benzoylecgonine, codeine, oxazepam and temazepam. Orbitrap also showed potential for retrospective investigation of ketamine metabolites in the samples without the need of additional analysis. Copyright © 2013 Elsevier B.V. All rights reserved.

  6. Feasibility of coupling a thermal/optical carbon analyzer to a quadrupole mass spectrometer for enhanced PM2.5 speciation.

    Science.gov (United States)

    Riggio, Gustavo M; Chow, Judith C; Cropper, Paul M; Wang, Xiaoliang; Yatavelli, Reddy L N; Yang, Xufei; Watson, John G

    2018-05-01

    A thermal/optical carbon analyzer (TOA), normally used for quantification of organic carbon (OC) and elemental carbon (EC) in PM 2.5 (fine particulate matter) speciation networks, was adapted to direct thermally evolved gases to an electron impact quadrupole mass spectrometer (QMS), creating a TOA-QMS. This approach produces spectra similar to those obtained by the Aerodyne aerosol mass spectrometer (AMS), but the ratios of the mass to charge (m/z) signals differ and must be remeasured using laboratory-generated standards. Linear relationships are found between TOA-QMS signals and ammonium (NH 4 + ), nitrate (NO 3 - ), and sulfate (SO 4 2- ) standards. For ambient samples, however, positive deviations are found for SO 4 2- , compensated by negative deviations for NO 3 - , at higher concentrations. This indicates the utility of mixed-compound standards for calibration or separate calibration curves for low and high ion concentrations. The sum of the QMS signals across all m/z after removal of the NH 4 + , NO 3 - , and SO 4 2- signals was highly correlated with the carbon content of oxalic acid (C₂H₂O₄) standards. For ambient samples, the OC derived from the TOA-QMS method was the same as the OC derived from the standard IMPROVE_A TOA method. This method has the potential to reduce complexity and costs for speciation networks, especially for highly polluted urban areas such as those in Asia and Africa. Ammonium, nitrate, and sulfate can be quantified by the same thermal evolution analysis applied to organic and elemental carbon. This holds the potential to replace multiple parallel filter samples and separate laboratory analyses with a single filter and a single analysis to account for a large portion of the PM 2.5 mass concentration.

  7. Image analyzing method to evaluate in situ bioluminescence from an obligate anaerobe cultivated under various dissolved oxygen concentrations.

    Science.gov (United States)

    Ninomiya, Kazuaki; Yamada, Ryuji; Matsumoto, Masami; Fukiya, Satoru; Katayama, Takane; Ogino, Chiaki; Shimizu, Nobuaki

    2013-02-01

    An image analyzing method was developed to evaluate in situ bioluminescence expression, without exposing the culture sample to the ambient oxygen atmosphere. Using this method, we investigated the effect of dissolved oxygen concentration on bioluminescence from an obligate anaerobe Bifidobacterium longum expressing bacterial luciferase which catalyzes an oxygen-requiring bioluminescent reaction. Copyright © 2012 The Society for Biotechnology, Japan. Published by Elsevier B.V. All rights reserved.

  8. Evaluation of the Nova StatSensor® XpressTM Creatinine Point-Of-Care Handheld Analyzer

    Science.gov (United States)

    Kosack, Cara Simone; de Kieviet, Wim; Bayrak, Kubra; Milovic, Anastacija; Page, Anne Laure

    2015-01-01

    Creatinine is a parameter that is required to monitor renal function and is important to follow in patients under treatment with potentially toxic renal drugs, such as the anti-HIV drug Tenofovir. A point of care instrument to measure creatinine would be useful for patients monitoring in resource-limited settings, where more instruments that are sophisticated are not available. The StatSensor Xpress Creatinine (Nova Biomedical Cooperation, Waltham, MA, USA) point of care analyzer was evaluated for its diagnostic performance in indicating drug therapy change. Creatinine was measured in parallel using the Nova StatSensor Xpress Creatinine analyzer and the Vitros 5,1FS (Ortho Clinical Diagnostics, Inc, Rochester, USA), which served as reference standard. The precision (i.e., repeatability and reproducibility) and accuracy of the StatSensor Xpress Creatinine analyzer were calculated using a panel of specimens with normal, low pathological and high pathological values. Two different Nova StatSensor Xpress Creatinine analyzers were used for the assessment of accuracy using repeated measurements. The coefficient of variation of the StatSensor Xpress Creatinine analyzers ranged from 2.3 to 5.9% for repeatability and from 4.2 to 9.0% for between-run reproducibility. The concordance correlation agreement was good except for high values (>600 µmol/L). The Bland-Altman analysis in high pathological specimens suggests that the Nova StatSensor Xpress Creatinine test tends to underestimate high creatinine values (i.e., >600 µmol/L). The Nova StatSensor Xpress Creatinine analyzers showed acceptable to good results in terms of repeatability, inter-device reproducibility and between-run reproducibility over time using quality control reagents. The analyzer was found sufficiently accurate for detecting pathological values in patients (age >10 year) and can be used with a moderate risk of misclassification. PMID:25886375

  9. Evaluation of the Nova StatSensor® Xpress(TM) Creatinine point-of-care handheld analyzer.

    Science.gov (United States)

    Kosack, Cara Simone; de Kieviet, Wim; Bayrak, Kubra; Milovic, Anastacija; Page, Anne Laure

    2015-01-01

    Creatinine is a parameter that is required to monitor renal function and is important to follow in patients under treatment with potentially toxic renal drugs, such as the anti-HIV drug Tenofovir. A point of care instrument to measure creatinine would be useful for patients monitoring in resource-limited settings, where more instruments that are sophisticated are not available. The StatSensor Xpress Creatinine (Nova Biomedical Cooperation, Waltham, MA, USA) point of care analyzer was evaluated for its diagnostic performance in indicating drug therapy change. Creatinine was measured in parallel using the Nova StatSensor Xpress Creatinine analyzer and the Vitros 5,1FS (Ortho Clinical Diagnostics, Inc, Rochester, USA), which served as reference standard. The precision (i.e., repeatability and reproducibility) and accuracy of the StatSensor Xpress Creatinine analyzer were calculated using a panel of specimens with normal, low pathological and high pathological values. Two different Nova StatSensor Xpress Creatinine analyzers were used for the assessment of accuracy using repeated measurements. The coefficient of variation of the StatSensor Xpress Creatinine analyzers ranged from 2.3 to 5.9% for repeatability and from 4.2 to 9.0% for between-run reproducibility. The concordance correlation agreement was good except for high values (>600 µmol/L). The Bland-Altman analysis in high pathological specimens suggests that the Nova StatSensor Xpress Creatinine test tends to underestimate high creatinine values (i.e., >600 µmol/L). The Nova StatSensor Xpress Creatinine analyzers showed acceptable to good results in terms of repeatability, inter-device reproducibility and between-run reproducibility over time using quality control reagents. The analyzer was found sufficiently accurate for detecting pathological values in patients (age >10 year) and can be used with a moderate risk of misclassification.

  10. Experimental evaluation of the objective virtual mass coefficient

    International Nuclear Information System (INIS)

    Heilbron Filho, Paulo Fernando Lavalle

    1984-04-01

    This work is a continuation of many others studies that have been made in the field of two-phase flow, concerning the influence of the void fraction in a parameter known as 'induced mass' that appears in the constitutive equation of the inter-phase force called 'virtual mass force'. The determination of the influence of the void fraction in the induced mass is done using experiment involving a bubble flow in a vertical tube filled with water. Using the two-phase flow model together with some hypothesis concerning the bubble flow experience and the constitutive equation for the virtual mass force, we achieve through the analysis of the filming of the experiment our purpose in determining the influence of the void fraction on the induced mass. (author)

  11. Improved accuracy and precision in δ15 NAIR measurements of explosives, urea, and inorganic nitrates by elemental analyzer/isotope ratio mass spectrometry using thermal decomposition.

    Science.gov (United States)

    Lott, Michael J; Howa, John D; Chesson, Lesley A; Ehleringer, James R

    2015-08-15

    Elemental analyzer systems generate N(2) and CO(2) for elemental composition and isotope ratio measurements. As quantitative conversion of nitrogen in some materials (i.e., nitrate salts and nitro-organic compounds) is difficult, this study tests a recently published method - thermal decomposition without the addition of O(2) - for the analysis of these materials. Elemental analyzer/isotope ratio mass spectrometry (EA/IRMS) was used to compare the traditional combustion method (CM) and the thermal decomposition method (TDM), where additional O(2) is eliminated from the reaction. The comparisons used organic and inorganic materials with oxidized and/or reduced nitrogen and included ureas, nitrate salts, ammonium sulfate, nitro esters, and nitramines. Previous TDM applications were limited to nitrate salts and ammonium sulfate. The measurement precision and accuracy were compared to determine the effectiveness of converting materials containing different fractions of oxidized nitrogen into N(2). The δ(13) C(VPDB) values were not meaningfully different when measured via CM or TDM, allowing for the analysis of multiple elements in one sample. For materials containing oxidized nitrogen, (15) N measurements made using thermal decomposition were more precise than those made using combustion. The precision was similar between the methods for materials containing reduced nitrogen. The %N values were closer to theoretical when measured by TDM than by CM. The δ(15) N(AIR) values of purchased nitrate salts and ureas were nearer to the known values when analyzed using thermal decomposition than using combustion. The thermal decomposition method addresses insufficient recovery of nitrogen during elemental analysis in a variety of organic and inorganic materials. Its implementation requires relatively few changes to the elemental analyzer. Using TDM, it is possible to directly calibrate certain organic materials to international nitrate isotope reference materials without off

  12. Selected cis- and trans-3-fluorostyrene rotamers studied by two-color resonant two-photon mass-analyzed threshold ionization spectroscopy

    Science.gov (United States)

    Wu, Pei Ying; Tzeng, Wen Bih

    2015-10-01

    We applied two-color resonant two-photon ionization and mass-analyzed threshold ionization techniques to record the vibronic, photoionization efficiency, and cation spectra of the selected rotamers of 3-fluorostyrene. The adiabatic ionization energies of cis- and trans-3-fluorostyrene were determined to be 69 960 ± 5 and 69 856 ± 5 cm-1, respectively. Cation vibrations 10a, 15, 6b, and 12 of both rotamers have been found to have frequencies of 218, 404, 452, and 971 cm-1, respectively. This finding shows that the relative orientation of the vinyl group with respect to the F atom does not affect these vibrations of the 3-fluorostyrene cation. Our one-dimensional potential energy surface calculations support that the cis-trans isomerization of 3-fluorostyrene does not occur under the present experimental conditions.

  13. A Liquid Chromatography-Quadrupole-Time of Flight Mass Spectrometry (LC-Q-TOF MS) Study for Analyzing 35 Corticosteroid Compounds: Elucidation of MS/MS Fragmentation Pathways

    International Nuclear Information System (INIS)

    Noh, Eunyoung; Yoon, Chang-Yong; Lee, Ji Hyun; Baek, Sun-Young; Do, Jung-Ah; Lee, Jung-min; Oh, Han Bin

    2016-01-01

    Corticosteroids have been often found to be added to a dietary supplement for the purpose of illegally improving the effect of their products. Thus, it is imperative to develop or improve a method that enables one to rapidly and reliably analyze corticosteroids in health or dietary supplements, for the safety management purpose. In the present study, results from liquid chromatography-quadrupole time-of-flight mass spectrometry (LC-Q-TOF-MS) experiments for the selected 35 corticosteroid compounds are presented, which can be useful for the qualitative screening of corticosteroids in health or dietary supplements. Specifically, retention times, accurate mass data of the protonated steroids, m/z values of major fragment ions are given for the 35 corticosteroids. Further, fragmentation pathways for the selected steroids are also suggested. Based on the suggested fragmentation pathways, it was shown that an unknown steroid compound can be readily identified using the knowledge of a group of unique and specific common skeletal fragments. The high selectivity and sensitivity of the LC-Q-TOF-MS/MS results combined with the knowledge of the fragmentation pathways can offer a new opportunity for rapid and accurate screening of corticosteroids, thus preventing health-related incidents involving adulterated products and clamping down on illegally circulated health products.

  14. A Liquid Chromatography-Quadrupole-Time of Flight Mass Spectrometry (LC-Q-TOF MS) Study for Analyzing 35 Corticosteroid Compounds: Elucidation of MS/MS Fragmentation Pathways

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Eunyoung; Yoon, Chang-Yong; Lee, Ji Hyun; Baek, Sun-Young; Do, Jung-Ah [Ministry of Food and Drug Safety, Cheongju (Korea, Republic of); Lee, Jung-min; Oh, Han Bin [Sogang University, Seoul (Korea, Republic of)

    2016-07-15

    Corticosteroids have been often found to be added to a dietary supplement for the purpose of illegally improving the effect of their products. Thus, it is imperative to develop or improve a method that enables one to rapidly and reliably analyze corticosteroids in health or dietary supplements, for the safety management purpose. In the present study, results from liquid chromatography-quadrupole time-of-flight mass spectrometry (LC-Q-TOF-MS) experiments for the selected 35 corticosteroid compounds are presented, which can be useful for the qualitative screening of corticosteroids in health or dietary supplements. Specifically, retention times, accurate mass data of the protonated steroids, m/z values of major fragment ions are given for the 35 corticosteroids. Further, fragmentation pathways for the selected steroids are also suggested. Based on the suggested fragmentation pathways, it was shown that an unknown steroid compound can be readily identified using the knowledge of a group of unique and specific common skeletal fragments. The high selectivity and sensitivity of the LC-Q-TOF-MS/MS results combined with the knowledge of the fragmentation pathways can offer a new opportunity for rapid and accurate screening of corticosteroids, thus preventing health-related incidents involving adulterated products and clamping down on illegally circulated health products.

  15. An investigation of electronic states of some molecules and molecular cations using mass analyzed threshold ionization and photoinduced Rydberg ionization spectroscopy

    Science.gov (United States)

    Hofstein, Jason David

    1999-11-01

    Mass analyzed threshold ionization (MATI) experiments have enabled mapping of the n-dependent Rydberg state survival probability for a series of molecules. Utilizing vacuum and extreme ultraviolet (VUV/XUV) photons, one photon Rydberg manifold spectra of argon, hydrogen chloride, nitrogen, benzene, and oxygen were produced, and the prospects of photoinduced Rydberg ionization (PIRI) experiments examined. It was found that the widths of Rydberg manifolds for the molecules studied are quite different. Hydrogen chloride and nitrogen have the narrowest manifold width, followed by benzene, and then oxygen. These varying widths are most strongly correlated with the angular momentum (i.e., quantum defect) of the initially prepared Rydberg orbital. PIRI experiments required the use of a static cell, rather than a molecular jet assembly, for the more efficient production of higher amounts of VUV/XUV radiation, and hence more Rydberg signal needed to observe PIRI. Armed with the ability to produce tunable VUV/XUV radiation, and to determine the feasibility of a PIRI experiment, the MATI and fragment PIRI spectra of trans-1,3-butadiene (BD) were recorded. The MATI spectrum is vibrationally resolved and was analyzed with the help of ab initio calculations and other published results. The fragment PIRI spectrum of the Aproduction of C3H3+ dominates, but at higher photon energies, C2H4 + is also produced. The production of each fragment showed a definite PIRI wavelength dependence.

  16. High-throughput simultaneous determination of plasma water deuterium and 18-oxygen enrichment using a high-temperature conversion elemental analyzer with isotope ratio mass spectrometry.

    Science.gov (United States)

    Richelle, M; Darimont, C; Piguet-Welsch, C; Fay, L B

    2004-01-01

    This paper presents a high-throughput method for the simultaneous determination of deuterium and oxygen-18 (18O) enrichment of water samples isolated from blood. This analytical method enables rapid and simple determination of these enrichments of microgram quantities of water. Water is converted into hydrogen and carbon monoxide gases by the use of a high-temperature conversion elemental analyzer (TC-EA), that are then transferred on-line into the isotope ratio mass spectrometer. Accuracy determined with the standard light Antartic precipitation (SLAP) and Greenland ice sheet precipitation (GISP) is reliable for deuterium and 18O enrichments. The range of linearity is from 0 up to 0.09 atom percent excess (APE, i.e. -78 up to 5725 delta per mil (dpm)) for deuterium enrichment and from 0 up to 0.17 APE (-11 up to 890 dpm) for 18O enrichment. Memory effects do exist but can be avoided by analyzing the biological samples in quintuplet. This method allows the determination of 1440 samples per week, i.e. 288 biological samples per week. Copyright 2004 John Wiley & Sons, Ltd.

  17. Hyphenation of a carbon analyzer to photo-ionization mass spectrometry to unravel the organic composition of particulate matter on a molecular level.

    Science.gov (United States)

    Grabowsky, Jana; Streibel, Thorsten; Sklorz, Martin; Chow, Judith C; Watson, John G; Mamakos, Athanasios; Zimmermann, Ralf

    2011-12-01

    The carbonaceous fraction of airborne particulate matter (PM) is of increasing interest due to the adverse health effects they are linked to. Its analytical ascertainment on a molecular level is still challenging. Hence, analysis of carbonaceous fractions is often carried out by determining bulk parameters such as the overall content of organic compounds (OC) and elemental carbon (EC) as well as the total carbon content, TC (sum of OC and EC), however, no information about the individual substances or substance classes, of which the single fractions consist can be obtained. In this work, a carbon analyzer and a photo-ionization time-of-flight mass spectrometer (PI-TOF-MS) were hyphenated to investigate individual compounds especially from the OC fractions. The carbon analyzer enables the stepwise heating of particle samples and provides the bulk parameters. With the PI-TOF-MS, it is possible to detect the organic compounds released during the single-temperature steps due to soft ionization and fast detection of the molecular ions. The hyphenation was designed, built up, characterized by standard substances, and applied to several kinds of samples, such as ambient aerosol, gasoline, and diesel emission as well as wood combustion emission samples. The ambient filter sample showed a strong impact of wood combustion markers. This was revealed by comparison to the product pattern of the similar analysis of pure cellulose and lignin and the wood combustion PM. At higher temperatures (450 °C), a shift to smaller molecules occurred due to the thermal decomposition of larger structures of oligomeric or polymeric nature comparable to lignocelluloses and similar oxygenated humic-like substances. Finally, particulate matter from gasoline and diesel containing 10% biodiesel vehicle exhaust has been analyzed. Gasoline-derived PM exhibited large polycyclic aromatic hydrocarbons, whereas diesel PM showed a much higher total organic content. The detected pattern revealed a strong

  18. CT evaluation of mass lesions in the parotid region

    International Nuclear Information System (INIS)

    Matsumoto, Shunichi; Kishikawa, Takashi; Kudo, Sho; Miyaji, Hiroshi; Kuwano, Haruo; Kaneko, Kuniyuki; Ohuchida, Toshiyuki

    1988-01-01

    CT findings of 35 patients with proven 31 parotid gland mass lesions (23 benign tumors, 5 malignant tumors, 3 inflammatory diseases) and 4 infraauricular lymphadenopathy (2 inflammatory nodes, 2 neoplastic nodes) were reviewed. CT accurately diagnosed the parotid origin in 29 of 31 parotid gland diseases. In all four patients with infraauricular lymphadenopathy, differentiation from parotid tumor was difficult. CT differentiation between superficial and deep lobe tumors agreed with surgical findings in 18 of 21 parotid gland tumors. Twenty out of 23 benign parotid gland tumors appeared as discrete masses with smooth margins. All five malignant parotid gland tumors appeared as poorly defined masses. It is concluded that when a tumor is located in the superficial lobe and appears as a sharply circumscribed mass on plain CT, it should be diagnosed as a benign lesion and contrast CT is not required. Secondly, contrast CT would be beneficial when a tumor is indistinct, or located in the deep portion of the parotid gland on plain CT. Finally, CT-sialography is considered unnecessary in the diagnosis of parotid masses. (author)

  19. Galaxy-M: a Galaxy workflow for processing and analyzing direct infusion and liquid chromatography mass spectrometry-based metabolomics data.

    Science.gov (United States)

    Davidson, Robert L; Weber, Ralf J M; Liu, Haoyu; Sharma-Oates, Archana; Viant, Mark R

    2016-01-01

    Metabolomics is increasingly recognized as an invaluable tool in the biological, medical and environmental sciences yet lags behind the methodological maturity of other omics fields. To achieve its full potential, including the integration of multiple omics modalities, the accessibility, standardization and reproducibility of computational metabolomics tools must be improved significantly. Here we present our end-to-end mass spectrometry metabolomics workflow in the widely used platform, Galaxy. Named Galaxy-M, our workflow has been developed for both direct infusion mass spectrometry (DIMS) and liquid chromatography mass spectrometry (LC-MS) metabolomics. The range of tools presented spans from processing of raw data, e.g. peak picking and alignment, through data cleansing, e.g. missing value imputation, to preparation for statistical analysis, e.g. normalization and scaling, and principal components analysis (PCA) with associated statistical evaluation. We demonstrate the ease of using these Galaxy workflows via the analysis of DIMS and LC-MS datasets, and provide PCA scores and associated statistics to help other users to ensure that they can accurately repeat the processing and analysis of these two datasets. Galaxy and data are all provided pre-installed in a virtual machine (VM) that can be downloaded from the GigaDB repository. Additionally, source code, executables and installation instructions are available from GitHub. The Galaxy platform has enabled us to produce an easily accessible and reproducible computational metabolomics workflow. More tools could be added by the community to expand its functionality. We recommend that Galaxy-M workflow files are included within the supplementary information of publications, enabling metabolomics studies to achieve greater reproducibility.

  20. Evaluation of Need and Location for a Thermogravimetric Analyzer in the Plutonium Finishing Plant (PFP) Materials Stabilization

    International Nuclear Information System (INIS)

    WILLIS, H.T.

    2000-01-01

    This plan provides an analysis for locating a TGA to support PFP Thermal Stabilization processes. The scope of this document is to evaluate the need for, and location for, installation of a TGA system as a supplement to the SFE equipment for moisture measurement in pure oxides. A location assessment for the SFE equipment was previously performed (HNF 1999). Based on that assessment, co-location of the TGA system with the SFE system is the preferred option. This would enable thermally stabilized material to be analyzed for residual moisture by either the TGA system or SFE system or both This evaluation considers glovebox locations in the PFP 234-52 Building Analytical Laboratory or operating areas for the installation of the TGA system and it's supporting equipment. This evaluation considers using existing gloveboxes along with an alternative of adding a new glovebox to existing process lines. The location evaluation criteria focuses mainly on glovebox size, with qualitative consideration of relative cost and schedule impacts associated with system implementation, radiological control, and interaction with other laboratory operations and processes. In addition, the possible co-location of a TGA furnace system with the SFE system was considered

  1. RADHEAT-V4: a code system to generate multigroup constants and analyze radiation transport for shielding safety evaluation

    International Nuclear Information System (INIS)

    Yamano, Naoki; Minami, Kazuyoshi; Koyama, Kinji; Naito, Yoshitaka.

    1989-03-01

    A modular code system RADHEAT-V4 has been developed for performing precisely neutron and photon transport analyses, and shielding safety evaluations. The system consists of the functional modules for producing coupled multi-group neutron and photon cross section sets, for analyzing the neutron and photon transport, and for calculating the atom displacement and the energy deposition due to radiations in nuclear reactor or shielding material. A precise method named Direct Angular Representation (DAR) has been developed for eliminating an error associated with the method of the finite Legendre expansion in evaluating angular distributions of cross sections and radiation fluxes. The DAR method implemented in the code system has been described in detail. To evaluate the accuracy and applicability of the code system, some test calculations on strong anisotropy problems have been performed. From the results, it has been concluded that RADHEAT-V4 is successfully applicable to evaluating shielding problems accurately for fission and fusion reactors and radiation sources. The method employed in the code system is very effective in eliminating negative values and oscillations of angular fluxes in a medium having an anisotropic source or strong streaming. Definitions of the input data required in various options of the code system and the sample problems are also presented. (author)

  2. Non-contact micro mass evaluation method using an X-ray microscope

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jiseok; Sun, Gwang Min; Baek, Ha Ni; Hoang, Sy Minh Tuan; Park, Sun Ae [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2017-07-15

    For the mass inspection of attached foils such as printed electrodes, mass should be measured by a non-contact method with the capacity to measure a small mass of micrograms. In this study, the masses of 1 mg to 10 mg electrodes were evaluated using an X-ray microscope. The results were compared with the masses determined by using a digital scale with a 0.005 mg error. The average of the relative error between the mass measurements using the X-ray microscope and those using the digital scale was less than 2.51%. The results show that X-ray mass evaluation method can be used for mass measurement of micro objects by replacing a digital scale.

  3. An evaluation of the 2012 measles mass vaccination campaign in ...

    African Journals Online (AJOL)

    Introduction: To estimate the post-campaign level of measles vaccination coverage in Guinea. Method: Interview of parents and observation of measles vaccination cards of children aged 9 to 59 months during the mass measles campaign. A nationwide cluster randomized sample under health District stratification. Results: ...

  4. Evaluating the Effectiveness of a Mass Media Ethics Course.

    Science.gov (United States)

    Lee, Byung; Padgett, George

    2000-01-01

    Examines the effectiveness of an ethics education component in a media law and ethics course. Suggests that a short-term mass media ethics study could not develop values considered essential for ethical behavior. Argues that students developed more complexity in their reasoning not measurable by the scale. Suggests a course or module on ethics…

  5. Computed tomographic evaluation of pulmonary mass lesion in chest radiography

    International Nuclear Information System (INIS)

    Choe, Kyu Ok

    1984-01-01

    Until recently, solitary coin lesion of pulmonary disease has been a conspicuous problem in radiologic diagnosis. It is now well informed that CT has offered high resolution with its objective CT numbers to provide additional information in terms of anatomic and pathologic changes. Here by the aid of CT, the authors has retrospectively patients with various shape of round masses thus illustrating the advantage of it over conventional X-ray in diagnosis. 1. Total 53 patients, including 34 males and 19 females, aging between 19 to 76 years old with nodule or mass of any size ranging 1 to 13 cm in diameter were observed. 2. On plain chest X-ray they were identified where 50 patients has single round nodular or mass, only one had two masses which were ecchinococcal cysts, and the rest two had invisible lesions, only detected by CT. 3. With philips tomoscan 310, CT scan was taken 12 mm thicken slice during quiet respiration. Using the ROI cursor the average CT number of the central area was calculated 1.0 cm in side the outer border of the mass. 4. As a consequence of their pathologic features, they were itemized to 4 group as 36 solid, 9 cystic, 4 consolidative and 4 cavitary lesions. 5. Correct diagnosis of 3 cystic lesions, 4 diffuse calcification, 1 A-V malformation were available by CT densitometry. 6. By the aid of better resolution and additional cross-sectional orientation of CT, 3 extrapulmonary lesions, 3 segmental consolidations, 2 bronchocele, and 2 solitary metastasis, were helpful in diagnosis. 7. Also helpful in determining the extent of intrathoracic extent of bronchogenic carcinoma for the same reason but given clues were not more than the ordinary. 8. However, the limitation of the CT densitometry led to miss diagnosis of 3 examples of cystic vs.solid lesions, and CT density of noncalcified granuloma together with bronchogenic carcinoma, did not have a clear cut separation in between.

  6. Traceability Assessment and Performance Evaluation of Results for Measurement of Abbott Clinical Chemistry Assays on 4 Chemistry Analyzers.

    Science.gov (United States)

    Lim, Jinsook; Song, Kyung Eun; Song, Sang Hoon; Choi, Hyun-Jung; Koo, Sun Hoe; Kwon, Gye Choel

    2016-05-01

    -The traceability of clinical results to internationally recognized and accepted reference materials and reference measurement procedures has become increasingly important. Therefore, the establishment of traceability has become a mandatory requirement for all in vitro diagnostics devices. -To evaluate the traceability of the Abbott Architect c8000 system (Abbott Laboratories, Abbott Park, Illinois), consisting of calibrators and reagents, across 4 different chemistry analyzers, and to evaluate its general performance on the Toshiba 2000FR NEO (Toshiba Medical Systems Corporation, Otawara-shi, Tochigi-ken, Japan). -For assessment of traceability, secondary reference materials were evaluated 5 times, and then bias was calculated. Precision, linearity, and carryover were determined according to the guidelines of the Clinical and Laboratory Standards Institute (Wayne, Pennsylvania). -The biases from 4 different analyzers ranged from -2.33% to 2.70% on the Toshiba 2000FR NEO, -2.33% to 5.12% on the Roche Hitachi 7600 (Roche Diagnostics International, Basel, Switzerland), -0.93% to 2.87% on the Roche Modular, and -2.16% to 2.86% on the Abbott Architect c16000. The total coefficients of variance of all analytes were less than 5%. The coefficients of determination (R(2)) were more than 0.9900. The carryover rate ranged from -0.54% to 0.17%. -Abbott clinical chemistry assays met the performance criteria based on desirable biological variation for precision, bias, and total error. They also showed excellent linearity and carryover. Therefore, these clinical chemistry assays were found to be accurate and reliable and are readily applicable on the various platforms used in this study.

  7. Ultrasonographic evaluation of masses of the abdominal walls in children

    International Nuclear Information System (INIS)

    Cairo, J.L.B.; Marins, J.L.C.; Prando, A.; Pereira, R.M.

    1988-01-01

    The sonographic features of seven cases of masses of the abdominal wall in children were reviewed. The sonographic manifestations of two cases of lipoma, two cases of abscess (one with intra-abdominal component), one case of lymph angioma, one case of capillary hemangioma and one due to a secondary involvement of a malignant retroperitoneal teratoma are presented. Ultrasound proved to be very useful modality in order to show the topography and the real extent of the disease. (author)

  8. Biomechanics of the cornea evaluated by spectral analysis of waveforms from ocular response analyzer and Corvis-ST.

    Directory of Open Access Journals (Sweden)

    Sushma Tejwani

    Full Text Available In this study, spectral analysis of the deformation signal from Corvis-ST (CoST and reflected light intensity from ocular response analyzer (ORA was performed to evaluate biomechanical concordance with each other.The study was non-interventional, observational, cross-sectional and involved 188 eyes from 94 normal subjects. Three measurements were made on each eye with ORA and CoST each and then averaged for each device. The deformation signal from CoST and reflected light intensity (applanation signal from ORA was compiled for all the eyes. The ORA signal was inverted about a line joining the two applanation peaks. All the signals were analyzed with Fourier series. The area under the signal curves (AUC, root mean square (RMS of all the harmonics, lower order (LO included 1st and 2nd order harmonic, higher order (HO up to 6th harmonic, CoST deformation amplitude (DA, corneal hysteresis (CH and corneal resistance factor (CRF were analyzed.The device variables and those calculated by Fourier transform were statistically significantly different between CoST and ORA. These variables also differed between the eyes of the same subject. There was also statistically significant influence of eyes (left vs. right on the differences in a sub-set of RMS variables only. CH and CRF differed statistically significantly between the eyes of subject (p<0.001 but not DA (p = 0.65.CoST was statistically significantly different from ORA. CoST may be useful in delineating true biomechanical differences between the eyes of a subject as it reports deformation.

  9. Evaluation of cryoanalysis as a tool for analyzing elemental distribution in “live” tardigrades using micro-PIXE

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, E.J.C., E-mail: charlotta.nilsson@nuclear.lu.se [Division of Nuclear Physics, Department of Physics, Lund University, Box 118, SE-221 00 Lund (Sweden); Pallon, J., E-mail: jan.pallon@nuclear.lu.se [Division of Nuclear Physics, Department of Physics, Lund University, Box 118, SE-221 00 Lund (Sweden); Przybylowicz, W.J., E-mail: przybylowicz@tlabs.ac.za [Materials Research Department, iThemba LABS, National Research Foundation, P.O. Box 722, Somerset West 7129 (South Africa); AGH University of Science and Technology, Faculty of Physics and Applied Computer Science, Al. A. Mickiewicza 30, 30-059 Krakow (Poland); Wang, Y.D., E-mail: yaodongw@hotmail.com [Materials Research Department, iThemba LABS, National Research Foundation, P.O. Box 722, Somerset West 7129 (South Africa); Jönsson, K.I., E-mail: ingemar.jonsson@hkr.se [School of Education and Environment, Kristianstad University, SE-291 88 Kristianstad (Sweden); Department of Molecular Biosciences, The Wenner-Gren Institute, Stockholm University, SE-106 91 Stockholm (Sweden)

    2014-08-01

    Although heavy on labor and equipment, thus not often applied, cryoanalysis of frozen hydrated biological specimens can provide information that better reflects the living state of the organism, compared with analysis in the freeze-dried state. In this paper we report a study where the cryoanalysis facility with cryosectioning capabilities at Materials Research Department, iThemba LABS, South Africa was employed to evaluate the usefulness of combining three ion beam analytical methods (μPIXE, RBS and STIM) to analyze a biological target where a better elemental compositional description is needed – the tardigrade. Imaging as well as quantification results are of interest. In a previous study, the element composition and redistribution of elements in the desiccated and active states of two tardigrade species was investigated. This study included analysis of both whole and sectioned tardigrades, and the aim was to analyze each specimen twice; first frozen hydrated and later freeze-dried. The combination of the three analytical techniques proved useful: elements from C to Rb in the tardigrades could be determined and certain differences in distribution of elements between the frozen hydrated and the freeze-dried states were observed. RBS on frozen hydrated specimens provided knowledge of matrix elements.

  10. Degradation studies of quizalofop-p and related compounds in soils using liquid chromatography coupled to low and high resolution mass analyzers.

    Science.gov (United States)

    López-Ruiz, Rosalía; Romero-González, Roberto; Martínez Vidal, José Luis; Fernández-Pérez, Manuel; Garrido Frenich, Antonia

    2017-12-31

    A comprehensive degradation study of quizalofop-p, quizalofop-p-ethyl, quizalofop-p-tefuryl and propaquizafop in soil samples have been firstly performed using ultra high performance liquid chromatography coupled to Orbitrap mass spectrometry (UHPLC-Orbitrap-MS). Thus, metabolites or degradation products, such as CHHQ (dihydroxychloroquinoxalin), CHQ (6-chloroquinoxalin-2-ol), PPA ((R)-2-(4-hydroxyphenoxy)propionic acid) and 2,3-dihydroxyquinoxaline were also monitored. An extraction procedure based on QuEChERS procedure was used. Acidified water (0.1M hydrochloric acid) and acidified acetonitrile (1% acetic acid, (v/v)) were used as extraction solvents, and magnesium sulfate and sodium chloride were used as salts. Dispersive solid phase extraction with C 18 as sorbent, was needed as a clean-up step. Several commercial products (Panarex®, Master-D® and Dixon®) were used to evaluate the degradation of the target compounds into their metabolites. The concentration of the main active substances (quizalofop-p-tefuryl, quizalofop-p-ethyl and propaquizafop) decreased during the degradation studies, whereas the concentration of quizalofop-p increased. Dissipation rates of half-live of quizalofop-p were also evaluated, and it was observed that this compound is easily degraded, obtaining values lower than 1day. Taking into account that quizalofop-p is the R enantiomer of quizalofop, a chiral separation was performed by liquid chromatography coupled to tandem mass spectrometry, concluding that in samples containing quizalofop-p-tefuryl, there was a 15% contribution from the S enantiomer and a 85% contribution from the R enantiomer. Metabolites such as PPA, CHHQ and CHQ were detected in soil samples after 15days of application commercial product at concentrations between the limits of detection (LOD) and the limits of quantification (LOQ). CHQ and CHHQ were detected at concentrations higher than the LOQ in samples after 50 and 80days of application, with their

  11. Determination of volatile organic compounds in water by headspace solid-phase microextraction gas chromatography coupled to tandem mass spectrometry with triple quadrupole analyzer

    International Nuclear Information System (INIS)

    Cervera, M.I.; Beltran, J.; Lopez, F.J.; Hernandez, F.

    2011-01-01

    Highlights: → Employing a statistical optimization improves results reducing experiments. → Use of MS (QqQ) allows high sensitivity determination and improves identification capabilities. → Using Q/q intensity ratios is a powerful tool to ensure compound identification. → HS SPME GC-MS/MS method allows determination of VOCs in complex matrix water samples. - Abstract: In the present work, a rapid method with little sample handling has been developed for determination of 23 selected volatile organic compounds in environmental and wastewater samples. The method is based on headspace solid-phase microextraction (SPME) followed by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS) determination using triple quadrupole analyzer (QqQ) in electron ionization mode. The best conditions for extraction were optimised with a factorial design taking into account the interaction between different parameters and not only individual effects of variables. In the optimized procedure, 4 mL of water sample were extracted using a 10 mL vial and adding 0.4 g NaCl (final NaCl content of 10%). An SPME extraction with carboxen/polydimethylsiloxane 75 μm fiber for 30 min at 50 deg. C (with 5 min of previous equilibration time) with magnetic stirring was applied. Chromatographic determination was carried out by GC-MS/MS working in Selected Reaction Monitoring (SRM) mode. For most analytes, two MS/MS transitions were acquired, although for a few compounds it was difficult to obtain characteristic abundant fragments. In those cases, a pseudo selected reaction monitoring (pseudo-SRM) with three ions was used instead. The intensity ratio between quantitation (Q) and confirmation (q) signals was used as a confirmatory parameter. The method was validated by means of recovery experiments (n = 6) spiking mineral water samples at three concentration levels (0.1, 5 and 50 μg L -1 ). Recoveries between 70% and 120% were generally obtained with relative standard deviations (RSDs

  12. Determination of volatile organic compounds in water by headspace solid-phase microextraction gas chromatography coupled to tandem mass spectrometry with triple quadrupole analyzer

    Energy Technology Data Exchange (ETDEWEB)

    Cervera, M.I. [Research Institute for Pesticides and Water, University Jaume I, Avda. Sos Baynat, E-12071 Castellon (Spain); Beltran, J., E-mail: joaquim.beltran@uji.es [Research Institute for Pesticides and Water, University Jaume I, Avda. Sos Baynat, E-12071 Castellon (Spain); Lopez, F.J.; Hernandez, F. [Research Institute for Pesticides and Water, University Jaume I, Avda. Sos Baynat, E-12071 Castellon (Spain)

    2011-10-17

    Highlights: {yields} Employing a statistical optimization improves results reducing experiments. {yields} Use of MS (QqQ) allows high sensitivity determination and improves identification capabilities. {yields} Using Q/q intensity ratios is a powerful tool to ensure compound identification. {yields} HS SPME GC-MS/MS method allows determination of VOCs in complex matrix water samples. - Abstract: In the present work, a rapid method with little sample handling has been developed for determination of 23 selected volatile organic compounds in environmental and wastewater samples. The method is based on headspace solid-phase microextraction (SPME) followed by gas chromatography coupled to tandem mass spectrometry (GC-MS/MS) determination using triple quadrupole analyzer (QqQ) in electron ionization mode. The best conditions for extraction were optimised with a factorial design taking into account the interaction between different parameters and not only individual effects of variables. In the optimized procedure, 4 mL of water sample were extracted using a 10 mL vial and adding 0.4 g NaCl (final NaCl content of 10%). An SPME extraction with carboxen/polydimethylsiloxane 75 {mu}m fiber for 30 min at 50 deg. C (with 5 min of previous equilibration time) with magnetic stirring was applied. Chromatographic determination was carried out by GC-MS/MS working in Selected Reaction Monitoring (SRM) mode. For most analytes, two MS/MS transitions were acquired, although for a few compounds it was difficult to obtain characteristic abundant fragments. In those cases, a pseudo selected reaction monitoring (pseudo-SRM) with three ions was used instead. The intensity ratio between quantitation (Q) and confirmation (q) signals was used as a confirmatory parameter. The method was validated by means of recovery experiments (n = 6) spiking mineral water samples at three concentration levels (0.1, 5 and 50 {mu}g L{sup -1}). Recoveries between 70% and 120% were generally obtained with

  13. Impact of collection conditions on the metabolite content of human urine samples as analyzed by liquid chromatography coupled to mass spectrometry and nuclear magnetic resonance spectroscopy.

    Science.gov (United States)

    Roux, Aurélie; Thévenot, Etienne A; Seguin, François; Olivier, Marie-Françoise; Junot, Christophe

    There is a lack of comprehensive studies documenting the impact of sample collection conditions on metabolic composition of human urine. To address this issue, two experiments were performed at a 3-month interval, in which midstream urine samples from healthy individuals were collected, pooled, divided into several aliquots and kept under specific conditions (room temperature, 4 °C, with or without preservative) up to 72 h before storage at -80 °C. Samples were analyzed by high-performance liquid chromatography coupled to high-resolution mass spectrometry and bacterial contamination was monitored by turbidimetry. Multivariate analyses showed that urinary metabolic fingerprints were affected by the presence of preservatives and also by storage at room temperature from 24 to 72 h, whereas no change was observed for urine samples stored at 4 °C over a 72-h period. Investigations were then focused on 280 metabolites previously identified in urine: 19 of them were impacted by the kind of sample collection protocol in both experiments, including 12 metabolites affected by bacterial contamination and 7 exhibiting poor chemical stability. Finally, our results emphasize that the use of preservative prevents bacterial overgrowth, but does not avoid metabolite instability in solution, whereas storage at 4 °C inhibits bacterial overgrowth at least over a 72-h period and slows the chemical degradation process. Consequently, and for further LC/MS analyses, human urine samples should be kept at 4 °C if their collection is performed over 24 h.

  14. A rapid method based on hot water extraction and liquid chromatography-tandem mass spectrometry for analyzing tetracycline antibiotic residues in cheese.

    Science.gov (United States)

    Bogialli, Sara; Coradazzi, Cristina; Di Corcia, Antonio; Lagana, Aldo; Sergi, Manuel

    2007-01-01

    A rapid, specific, and sensitive procedure for determining residues of 4 widely used tetracycline antibiotics and 3 of their 4-epimers in cheese is presented. The method is based on the matrix solid-phase dispersion (MSPD) technique followed by liquid chromatography/tandem mass spectrometry (LC/MS/MS). After dispersing samples of mozzarella, asiago, parmigiano, gruyere, emmenthal, and camembert on sand, target compounds were eluted from the MSPD column by passing through it 6 mL water heated at 70 degrees C. After acidification and filtration, 200 microL of the aqueous extract was directly injected into the LC column. For analyte identification and quantification, MS data acquisition was performed in the multireaction monitoring mode, selecting 2 precursor ion-to-product ion transitions for each target compound. Hot water appeared to be an efficient extractant, because absolute recoveries were no lower than 78%. Using demeclocycline as a surrogate analyte, recoveries of analyte added to the 6 types of cheeses at the 30 ng/g level were 96-117%, with relative standard deviation (RSD) not higher than 9%. Statistical analysis of the mean recovery data showed that the extraction efficiency was not dependent on the type of cheese analyzed. This result indicates that this method could be applied to other cheese types not considered here. At the lowest concentration considered, i.e., 10 ng/g, the accuracy of the method ranged between 90 and 107%, with RSDs not larger than 12%. Based on a signal-to-noise ratio of 10, limits of quantitation were estimated to be 1-2 ng/g.

  15. Radiological evaluation of the intraabdominal masses in childhood

    International Nuclear Information System (INIS)

    Kim, Y. J.; Oh, K. K.; Park, C. Y.

    1980-01-01

    The spectrum of types of cancer in childhood differs strikingly from that in adults. Leukemia, central nervous system tumors, embryonal tumors, and sarcomas are much more common in children than are adenocarcinoma and carcinomas, which constitute the majority of cancers in adults. In children under 15 years of age, intraabdominal tumors are the third most common one, preceded only by leukemia and brain tumors. It is well recognized that these tumors remain silent until they assume huge size, and early detection and treatment are important. X-ray examination is the most important method among diagnostic approaches. 150 cases of intraabdominal masses were reviewed in respect of age, sex, incidence, site of origin and radiographic findings. The results are summarized as follows; 1. The most common site was retroperitoneum (80 cases: 53.3%), followed by intraperitoneum (47 cases: 31.3%), and pelvic cavity (23 cases: 15.4%). The kidney was the single most common site of origin (33%). 2. Hydronephrosis was most common (23 cases: 15.3%) and Wilms' tumor (22 cases: 14.7%), teratoma (21 cases: 14.0%), and neuroblastoma (18 cases: 12.0%) were descending order of frequency. One renal cell carcinoma in 9 year old female patient and bilateral duplications of pelvis with ureteroceles in 5 month old twin infants were found. 3. Male outnumbered female in most childhood abdominal diseases, however female was predominant in teratoma (1:20) and choledochal cyst (3:7). 97 cases were under the age of 5 years. 4. Radiographic findings were as follow, a. Simple abdomen: In retroperitoneal tumors, mass shadows were the most common finding (89.7%) and obliteration of psoas shadows was noted in 73%. Calcifications were seen in 6 cases (100%) of teratoma as bone, teeth or amorphous, 1 case (4.5%) of Wilms' tumor as amorphous, and 5 cases (33%) or neuroblastoma as amorphous or psammomatous. Fat shadow was seen in 5 cases (83%) of teratoma. In intraperitoneal tumors, mass was the most common

  16. The Índice Flesch-Szigriszt and Spanish Lexile Analyzer to evaluate Spanish patient education materials in otolaryngology.

    Science.gov (United States)

    Nassif, Samih J; Wong, Kevin; Levi, Jessica R

    2018-01-01

    Evaluate the reading difficulty of Spanish patient education materials using the validated Índice Flesch-Szigriszt (INFLESZ) and Spanish Lexile Analyzer, and to identify relationships between English and Spanish readability formulas. Cross-sectional analysis. All otolaryngology-related patient education articles written in Spanish from the health libraries of the top 10 US News & World Report-ranked hospitals, top 10 Doximity-ranked otolaryngology residencies, the American Academy of Otolaryngology-Head and Neck Surgery website, and the US National Library of Medicine online section on ears, nose and throat were collected. Reading difficulty was assessed using the INFLESZ and Spanish Lexile Analyzer. Additional readability assessments included the traditional English tools: Flesch-Kincaid Grade Level, Flesch Reading Ease Score, and the Simple Measure of Gobbledygook score. A total of 497 articles were reviewed. The average INFLESZ score for all articles was 57.75, which is considered normal and requires the reading ability of a student who finished Escuela Secundaria Obligatoria or 10th grade equivalent in the United States. The average Spanish Lexile measure for all articles was 1062L, equivalent to a reading level between the 6th and 12th grade. English readability tools calculated a more difficult reading level compared to Spanish tools when performed on the same text. Current Spanish patient education materials in otolaryngology may be too difficult for the average Spanish-speaking reader to understand. Future improvements may be warranted to improve the readability of educational materials and increase health literacy. NA. Laryngoscope, 128:E21-E26, 2018. © 2017 The American Laryngological, Rhinological and Otological Society, Inc.

  17. Analyzing implementation dynamics using theory-driven evaluation principles: lessons learnt from a South African centralized chronic dispensing model.

    Science.gov (United States)

    Magadzire, Bvudzai Priscilla; Marchal, Bruno; Mathys, Tania; Laing, Richard O; Ward, Kim

    2017-12-04

    Centralized dispensing of essential medicines is one of South Africa's strategies to address the shortage of pharmacists, reduce patients' waiting times and reduce over-crowding at public sector healthcare facilities. This article reports findings of an evaluation of the Chronic Dispensing Unit (CDU) in one province. The objectives of this process evaluation were to: (1) compare what was planned versus the actual implementation and (2) establish the causal elements and contextual factors influencing implementation. This qualitative study employed key informant interviews with the intervention's implementers (clinicians, managers and the service provider) [N = 40], and a review of policy and program documents. Data were thematically analyzed by identifying the main influences shaping the implementation process. Theory-driven evaluation principles were applied as a theoretical framework to explain implementation dynamics. The overall participants' response about the CDU was positive and the majority of informants concurred that the establishment of the CDU to dispense large volumes of medicines is a beneficial strategy to address healthcare barriers because mechanical functions are automated and distribution of medicines much quicker. However, implementation was influenced by the context and discrepancies between planned activities and actual implementation were noted. Procurement inefficiencies at central level caused medicine stock-outs and affected CDU activities. At the frontline, actors were aware of the CDU's implementation guidelines regarding patient selection, prescription validity and management of non-collected medicines but these were adapted to accommodate practical realities and to meet performance targets attached to the intervention. Implementation success was a result of a combination of 'hardware' (e.g. training, policies, implementation support and appropriate infrastructure) and 'software' (e.g. ownership, cooperation between healthcare

  18. Application of Six Sigma Model to Evaluate the Analytical Quality of Four HbA1c Analyzers.

    Science.gov (United States)

    Maesa, Jos Eacute M; Fern Aacute Ndez-Riejos, Patricia; S Aacute Nchez-Mora, Catalina; Toro-Crespo, Mar Iacute A De; Gonz Aacute Lez-Rodriguez, Concepci Oacute N

    2017-01-01

    The Six Sigma Model is a global quality management system applicable to the determination of glycated hemoglobin (HbA1c). In addition, this model can ensure the three characteristics influencing the patient risk: the correct performance of the analytical method with low inaccuracy and bias, the quality control strategy used by the laboratory, and the necessary quality of the analyte. The aim of this study is to use the Six Sigma Model for evaluating quality criteria in the determination of glycated hemoglobin HbA1c and its application to assess four different HbA1c analyzers. Four HbA1c analyzers were evaluated: HA-8180V®, D-100®, G8®, and Variant II Turbo®. For 20 consecutive days, two levels of quality control (high and low) provided by the manufacturers were measured in each of the instruments. Imprecision (CV), bias, and Sigma values (σ) were calculated with the data obtained and a method decision chart was developed considering a range of quality requirements (allowable total error, TEa). For a TEa = 3%, HA-8180V = 1.54 σ, D-100 = 1.63 σ, G8 = 2.20 σ, and Variant II Turbo = -0.08 σ. For a TEa = 4%, HA-8180V = 2.34 σ, D-100 = 2.32 σ, G8 = 3.74 σ, and Variant II Turbo = 0.16 σ. For a TEa = 10%, HA8180V = 7.12 σ, D-100 = 6.46 σ, G8 = 13.0 σ, and Variant II Turbo = 1.56 σ. Applying the Stockholm consensus and its subsequent Milan review to the results: the maximum level in quality requirements for HbA1c is an allowable total error (TEa) = 3%, G8 is located in region 2 σ (2.20), which is a poor result, and HA-8180V and D-100 are both in region 1 σ (1.54 and 1.63, respectively), which is an unacceptable analytical performance.

  19. Evaluation of a mass media campaign promoting using help to quit smoking.

    Science.gov (United States)

    Gibson, Laura A; Parvanta, Sarah A; Jeong, Michelle; Hornik, Robert C

    2014-05-01

    Although there is evidence that promoting individual cessation aids increases their utilization, mass media campaigns highlighting the benefit of using help to quit have not been evaluated. The effects of a Philadelphia adult smoking-cessation media campaign targeting using help in ad taglines were analyzed from March to November 2012. This study distinctively analyzed the campaign's impact at both the population level (effects on the average person) and the individual level (effects among those who reported exposure). The 16-month mass media campaign aired in Philadelphia PA from December 2010 to March 2012. A representative sample of adult Philadelphia smokers was interviewed by telephone at baseline (n=491) and new samples were interviewed monthly throughout the campaign (n=2,786). In addition, a subsample of these respondents was reinterviewed 3 months later (n=877). On average, participants reported seeing campaign ads four times per week. Among individual respondents, each additional campaign exposure per week increased the likelihood of later reporting using help (OR=1.08, p<0.01), adjusting for baseline use of help and other potential confounders. This corresponded to a 5% increase in the use of help for those with average exposure relative to those with no exposure. Cross-sectional associations between individual campaign exposure and intentions to use help were consistent with these lagged findings. However, there was no evidence of population-level campaign effects on use of help. Although the campaign was effective at the individual level, its effects were too small to have a population-detectable impact. Copyright © 2014 American Journal of Preventive Medicine. Published by Elsevier Inc. All rights reserved.

  20. Evaluation of biochars by temperature programmed oxidation/mass spectrometry

    Science.gov (United States)

    Michael Jackson; Thomas Eberhardt; Akwasi Boateng; Charles Mullen; Les Groom

    2013-01-01

    Biochars produced from thermochemical conversions of biomass were evaluated by temperature programmed oxidation (TPO). This technique, used to characterize carbon deposits on petroleum cracking catalysts, provides information on the oxidative stability of carbonaceous solids, where higher temperature reactivity indicates greater structural order, an important property...

  1. Transient analyzer

    International Nuclear Information System (INIS)

    Muir, M.D.

    1975-01-01

    The design and design philosophy of a high performance, extremely versatile transient analyzer is described. This sub-system was designed to be controlled through the data acquisition computer system which allows hands off operation. Thus it may be placed on the experiment side of the high voltage safety break between the experimental device and the control room. This analyzer provides control features which are extremely useful for data acquisition from PPPL diagnostics. These include dynamic sample rate changing, which may be intermixed with multiple post trigger operations with variable length blocks using normal, peak to peak or integrate modes. Included in the discussion are general remarks on the advantages of adding intelligence to transient analyzers, a detailed description of the characteristics of the PPPL transient analyzer, a description of the hardware, firmware, control language and operation of the PPPL transient analyzer, and general remarks on future trends in this type of instrumentation both at PPPL and in general

  2. STRAPS v1.0: evaluating a methodology for predicting electron impact ionisation mass spectra for the aerosol mass spectrometer

    Directory of Open Access Journals (Sweden)

    D. O. Topping

    2017-06-01

    Full Text Available Our ability to model the chemical and thermodynamic processes that lead to secondary organic aerosol (SOA formation is thought to be hampered by the complexity of the system. While there are fundamental models now available that can simulate the tens of thousands of reactions thought to take place, validation against experiments is highly challenging. Techniques capable of identifying individual molecules such as chromatography are generally only capable of quantifying a subset of the material present, making it unsuitable for a carbon budget analysis. Integrative analytical methods such as the Aerosol Mass Spectrometer (AMS are capable of quantifying all mass, but because of their inability to isolate individual molecules, comparisons have been limited to simple data products such as total organic mass and the O : C ratio. More detailed comparisons could be made if more of the mass spectral information could be used, but because a discrete inversion of AMS data is not possible, this activity requires a system of predicting mass spectra based on molecular composition. In this proof-of-concept study, the ability to train supervised methods to predict electron impact ionisation (EI mass spectra for the AMS is evaluated. Supervised Training Regression for the Arbitrary Prediction of Spectra (STRAPS is not built from first principles. A methodology is constructed whereby the presence of specific mass-to-charge ratio (m∕z channels is fitted as a function of molecular structure before the relative peak height for each channel is similarly fitted using a range of regression methods. The widely used AMS mass spectral database is used as a basis for this, using unit mass resolution spectra of laboratory standards. Key to the fitting process is choice of structural information, or molecular fingerprint. Our approach relies on using supervised methods to automatically optimise the relationship between spectral characteristics and these molecular

  3. STRAPS v1.0: evaluating a methodology for predicting electron impact ionisation mass spectra for the aerosol mass spectrometer

    Science.gov (United States)

    Topping, David O.; Allan, James; Rami Alfarra, M.; Aumont, Bernard

    2017-06-01

    Our ability to model the chemical and thermodynamic processes that lead to secondary organic aerosol (SOA) formation is thought to be hampered by the complexity of the system. While there are fundamental models now available that can simulate the tens of thousands of reactions thought to take place, validation against experiments is highly challenging. Techniques capable of identifying individual molecules such as chromatography are generally only capable of quantifying a subset of the material present, making it unsuitable for a carbon budget analysis. Integrative analytical methods such as the Aerosol Mass Spectrometer (AMS) are capable of quantifying all mass, but because of their inability to isolate individual molecules, comparisons have been limited to simple data products such as total organic mass and the O : C ratio. More detailed comparisons could be made if more of the mass spectral information could be used, but because a discrete inversion of AMS data is not possible, this activity requires a system of predicting mass spectra based on molecular composition. In this proof-of-concept study, the ability to train supervised methods to predict electron impact ionisation (EI) mass spectra for the AMS is evaluated. Supervised Training Regression for the Arbitrary Prediction of Spectra (STRAPS) is not built from first principles. A methodology is constructed whereby the presence of specific mass-to-charge ratio (m/z) channels is fitted as a function of molecular structure before the relative peak height for each channel is similarly fitted using a range of regression methods. The widely used AMS mass spectral database is used as a basis for this, using unit mass resolution spectra of laboratory standards. Key to the fitting process is choice of structural information, or molecular fingerprint. Our approach relies on using supervised methods to automatically optimise the relationship between spectral characteristics and these molecular fingerprints. Therefore

  4. [Evaluation of the analyzer of hematology Beckman Coulter® HmX™ in the university hospital of Oran].

    Science.gov (United States)

    Zmouli, N; Moulasserdoun, K; Seghier, F

    2013-11-01

    The choice of an automaton of haematology is a determining stage, which has to take into account at the same time the quality of the results and the economic imperatives: workload, structure and organization of the laboratory. [corrected] It is in this spirit that we estimated during a period of 3 months the analyzer of haematology: the HmX™ Coulter with boatman of samples of the company Beckman. This automaton realizes the blood numeration, the formula leukocytic and the reticulocyte count. At first, we estimated the appropriate characteristics of device. Secondly, we estimated the relevance, the sensibility and the specificity of the alarms by comparing with the reference method, which is the optical microscopy. For that purpose, 125 blood smears resulting from service of haematology and from resuscitation were examined in optical microscopy. The technical tests were realized according to the recommendations of the International committee for evaluation of automatons of haematology. The analytical performances were satisfactory in particular the big interval of linearity and the absence of contamination. As regards the evaluation of the alarms system: rate of rejection is 63%, the sensibility 86%, the specificity 70%, the positive predictive value 80%, the negative predictive value 78% and the efficiency 80%. The alarms myelaemia and atypical lymphocytes were never sources of false negatives. The alarms erythroblasts and platelet aggregates did not engendered positive forgery. The blast cell alarm was responsible for a single case of false negative. The faithfulness of automaton is satisfactory: the absence of contamination, the big interval of linearity for the leukocytes, the red blood cells and the platelets as well as a good relevance of the alarms with regard to the anomalies found on the peripheral blood smear. From the user-friendliness and practicability point of view, the HmX™ Coulter was deeply appreciated. Copyright © 2013 Elsevier Masson SAS. All

  5. Evaluation of trail-cameras for analyzing the diet of nesting raptors using the Northern Goshawk as a model.

    Science.gov (United States)

    García-Salgado, Gonzalo; Rebollo, Salvador; Pérez-Camacho, Lorenzo; Martínez-Hesterkamp, Sara; Navarro, Alberto; Fernández-Pereira, José-Manuel

    2015-01-01

    Diet studies present numerous methodological challenges. We evaluated the usefulness of commercially available trail-cameras for analyzing the diet of Northern Goshawks (Accipiter gentilis) as a model for nesting raptors during the period 2007-2011. We compared diet estimates obtained by direct camera monitoring of 80 nests with four indirect analyses of prey remains collected from the nests and surroundings (pellets, bones, feather-and-hair remains, and feather-hair-and-bone remains combined). In addition, we evaluated the performance of the trail-cameras and whether camera monitoring affected Goshawk behavior. The sensitivity of each diet-analysis method depended on prey size and taxonomic group, with no method providing unbiased estimates for all prey sizes and types. The cameras registered the greatest number of prey items and were probably the least biased method for estimating diet composition. Nevertheless this direct method yielded the largest proportion of prey unidentified to species level, and it underestimated small prey. Our trail-camera system was able to operate without maintenance for longer periods than what has been reported in previous studies with other types of cameras. Initially Goshawks showed distrust toward the cameras but they usually became habituated to its presence within 1-2 days. The habituation period was shorter for breeding pairs that had previous experience with cameras. Using trail-cameras to monitor prey provisioning to nests is an effective tool for studying the diet of nesting raptors. However, the technique is limited by technical failures and difficulties in identifying certain prey types. Our study also shows that cameras can alter adult Goshawk behavior, an aspect that must be controlled to minimize potential negative impacts.

  6. Evaluation of trail-cameras for analyzing the diet of nesting raptors using the Northern Goshawk as a model.

    Directory of Open Access Journals (Sweden)

    Gonzalo García-Salgado

    Full Text Available Diet studies present numerous methodological challenges. We evaluated the usefulness of commercially available trail-cameras for analyzing the diet of Northern Goshawks (Accipiter gentilis as a model for nesting raptors during the period 2007-2011. We compared diet estimates obtained by direct camera monitoring of 80 nests with four indirect analyses of prey remains collected from the nests and surroundings (pellets, bones, feather-and-hair remains, and feather-hair-and-bone remains combined. In addition, we evaluated the performance of the trail-cameras and whether camera monitoring affected Goshawk behavior. The sensitivity of each diet-analysis method depended on prey size and taxonomic group, with no method providing unbiased estimates for all prey sizes and types. The cameras registered the greatest number of prey items and were probably the least biased method for estimating diet composition. Nevertheless this direct method yielded the largest proportion of prey unidentified to species level, and it underestimated small prey. Our trail-camera system was able to operate without maintenance for longer periods than what has been reported in previous studies with other types of cameras. Initially Goshawks showed distrust toward the cameras but they usually became habituated to its presence within 1-2 days. The habituation period was shorter for breeding pairs that had previous experience with cameras. Using trail-cameras to monitor prey provisioning to nests is an effective tool for studying the diet of nesting raptors. However, the technique is limited by technical failures and difficulties in identifying certain prey types. Our study also shows that cameras can alter adult Goshawk behavior, an aspect that must be controlled to minimize potential negative impacts.

  7. Evaluation difference between mass of received cargo and mass of handed over the cargo in the determination of the masses by draft survey

    Directory of Open Access Journals (Sweden)

    Yakuta I. V.

    2016-12-01

    Full Text Available The paper provides the analysis of problems associated with the evaluation of difference between the mass of received and handed over cargo in determining the masses by draft survey and due to the difference in the measurement conditions at the loading and unloading ports (due to the change errors in various stages of the measurement procedures. The errors that may arise in determining the mass of the cargo due to roughness when measuring draft, due to using the inclinometer to determine the draft from one of boards, due to instrumental errors in the determination of the density of seawater, due to other possible errors have been investigated and evaluated. To estimate the errors of draft due to heaving and errors of inclinometer some formula are to be applied, their derivation has been done in this paper. It has been recommended to use the traditional formula of high-speed drawdown with the replacement of vessel speed on current rate to calculate the error of precipitation arising from the drawdowns ship on a current. The value per unit displacement draft from loading scale has been used to evaluate the error of the displacement appearing in the presence of draft errors. As a result two similar criteria (rigorous and statistical of allowable discrepancies calculated by draft survey mass of cargo in the port of loading and port of discharge have been substantiated. These criteria require the calculation and accumulation in a table of all the errors and calculate the total error of displacement. Criteria will allow the consignee and the carrier come to a reasonable and agreed decision about the significance of differences of the masses taking into account the indifference of conditions and measuring instruments.

  8. Evaluation of Fluidized Beds for Mass Production of IFE Targets

    International Nuclear Information System (INIS)

    Huang, H.; Vermillion, B.A.; Brown, L.C.; Besenbruch, G.E.; Goodin, D.T.; Stemke, R.W.; Stephens, R.B.

    2005-01-01

    Of the building blocks of an inertial fusion energy (IFE) plant, target fabrication remains a significant credibility issue. For this reason, an extensive parametric study has been conducted on mass production of glow discharge polymer (GDP) shells in a vertical fluidized bed. Trans-2-butene was used as a reactant gas with hydrogen as a diluting and etching agent. Coating rates in the range of 1 to 2 μm/h were demonstrated on batches of 30 shells where National Ignition Facility-quality surfaces were obtained for 3- to 5-μm-thick coatings. Thick coatings up to 325 μm were also demonstrated that are visually transparent, without void and stress fracture. A phenomenological understanding of the GDP growth mechanisms to guide future experiments was further established. Specifically, gas-phase precipitation and high-impact collisions were identified as the main surface-roughening mechanisms. The former produces dense cauliflower-like surface patterns that can be eliminated by adjusting the gas flow rates and the flow ratio. The latter produces isolated domelike surface defects that can be reduced by introducing concerted motion between the shells. By converting from a vertical to a horizontal configuration, fully transparent coatings were obtained on 350 shells. Collisions in a fluidized bed have been identified as the limiting factor in meeting IFE specifications, and a related-rotary kiln technique is recommended for scale-up

  9. Comparison of slitlamp optical coherence tomography and scanning peripheral anterior chamber depth analyzer to evaluate angle closure in Asian eyes.

    Science.gov (United States)

    Wong, Hon-Tym; Chua, Jocelyn L L; Sakata, Lisandro M; Wong, Melissa H Y; Aung, Han T; Aung, Tin

    2009-05-01

    To evaluate the effectiveness of slitlamp optical coherence tomography (SL-OCT) and Scanning Peripheral Anterior Chamber depth analyzer (SPAC) in detecting angle closure, using gonioscopy as the reference standard. A total of 153 subjects underwent gonioscopy, SL-OCT, and SPAC. The anterior chamber angle (ACA) was classified as closed on gonioscopy if the posterior trabecular meshwork could not be seen; with SL-OCT, closure was determined by contact between the iris and angle wall anterior to the scleral spur; and with SPAC by a numerical grade of 5 or fewer and/or a categorical grade of suspect or potential. A closed ACA was identified in 51 eyes with gonioscopy, 86 eyes with SL-OCT, and 61 eyes with SPAC (gonioscopy vs SL-OCT, P gonioscopy vs SPAC, P = .10; SL-OCT vs SPAC, P gonioscopy, SL-OCT detected a closed ACA in 43, whereas SPAC identified 41 (P = .79). An open angle in all 4 quadrants was observed in 102 eyes with gonioscopy, but SL-OCT and SPAC identified 43 and 20 of these eyes, respectively, as having angle closure. The overall sensitivity and specificity for SL-OCT were 84% and 58% vs 80% and 80% for SPAC. Using gonioscopy as the reference, SL-OCT and SPAC showed good sensitivity for detecting eyes at risk of angle closure.

  10. Formation and evaluation of convex-curved crystals of lithium fluoride for use in analyzing x-ray spectra

    International Nuclear Information System (INIS)

    Sellick, B.O.

    1976-01-01

    Lithium fluoride as received from the vendor in boule form is 38 x 38 x 13 mm thick. This block is cleaved to wafers of the desired thickness, x-ray-evaluated for ''d'' spacing and greatest intensity, bent to the required radius, and then acid-etched to remove foreign material. The diffraction and dispersion characteristics of a wafer are analyzed using well-collimated tungsten x rays that strike the crystal and are diffracted onto no-screen x-ray film. If the crystal is satisfactory, it is mounted in a spectrogoniometer and rotated through an x-ray beam while a detector is set at the optimized angle for the diffracted x rays. The average intensity across the length of the crystal is recorded by multichannel scaling. Any imperfections appear as peaks or dips compared to the average intensity. The crystal next goes to a 10-channel, filter-fluorescer x-ray unit that compares zero-order intensity to diffracted Kα and Kβ intensity. Counts for 100-s intervals are taken in groups of three and averaged. Correction factors for instrument geometry, air, pinhole diameter at zero order, Kα-Kβ, barometric pressure, temperature, etc., are added to the efficiency calculations to obtain the crystal efficiency (epsilon) vs keV data. The crystal is mounted in the spectrograph or spectrometer and calibrated to either the detector or film plane by using direct radiation with proper x-ray filters or absorbers. The crystal is then ready for use

  11. A Java-platform software for the evaluation of mass attenuation and ...

    African Journals Online (AJOL)

    A computer software was written for the evaluation of mass attenuation coefficient (μ/ρ) and mass energy-absorption coefficient (μ /ρ) for body tissues and substitutes of arbitrary elemental composition and en percentage-by-weight of elemental constituents using the Java development platform which could run on any ...

  12. Method for Analyzing Trade-offs in Biomass Management in Smallholder Farming Systems Based on Mass Balance: A Case Study in Tajikistan's Foothills

    Directory of Open Access Journals (Sweden)

    Sebastian Ruppen

    2016-02-01

    Full Text Available In smallholder farming systems, especially in mountainous areas, households face trade-offs between meeting short-term human needs and ensuring long-term soil productivity. Improved biomass management can help break the downward spiral of overexploitation of natural resources, land degradation, and productivity decline, and support more sustainable use of marginal land. Mixed crop/livestock systems are often carefully balanced to minimize risks. Thus, when planning interventions, profound systems knowledge is crucial. However, the data required for system characterization are often scarce, and original field studies are thus necessary. The aim of this research, a case study in Tajikistan, was to improve systems understanding of the biomass cycle in crop/livestock systems in order to quantify the obstacles to the spread of sustainable land management technologies to farming households. It aimed to establish a database and methods of rapid data collection to quantify the stocks and flows of biomass, with a focus on mass balances, and to evaluate smallholders’ biomass management options and trade-offs. Data collection included household interviews, secondary literature, and reference data sets from global sources. Trade-off analysis focused on household-level self-supply of food, fodder, and fuel by farmers with different sizes of smallholdings, and their potential for on-farm recycling of organic matter. Results indicate that food self-supply by small and medium smallholders is insufficient and fodder sources are scarce. Fodder scarcity means that application of crop byproducts to soils is unlikely. Animal dung is largely used as fuel. Firewood needs exceed on-farm wood production, leading to deforestation. The approach presented facilitates an understanding of current and potential agricultural land interventions in the crop/livestock farming systems prevailing in mountainous areas.

  13. Evaluating the risk of osteoporosis through bone mass density

    International Nuclear Information System (INIS)

    Sayed, S.A.; Khaliq, A.

    2017-01-01

    Osteoporosis is a bone disorder, characterized by loss of bone mass density. Osteoporosis affects more than 30 percent of post-menopausal women. Osteoporosis is often associated with restricted body movement, pain and joint deformities. Early identification and early intervention can help in reducing these complications. The primary objective of this study was to estimate the burden of Osteoporosis in Urban setting of Sindh among women of different age groups and to access the effect of different protective measures that can reduce the risk of Osteoporosis. Method: In this study, 500 women's of 3 major cities of Sindh were approached by non-probability convenience sampling technique. Women bearing age 20 years or more were included. Women who fall under inclusion criteria were screened for BMD (Bone mineral density) test and were classified as Healthy, Osteopenic and Osteoporotic based on their T-score. The association of different protective measures and risk of osteoporosis was assessed by prevalence relative risk (PRR). Result: The result of this study indicate that the burden of Osteoporosis is very high among the women of Sindh, only 17.4 percent (84) women were found to have normal BMD score. The life style of majority of women was sedentary. The PRR calculated for Exposure to sunlight, regular exercise, and use of nutritional supplement was 12.5, 5.19 and 2.72 folds respectively. Conclusion: The results of study reveal that exposure to sunlight, regular physical exercise and use of nutritional supplements found to be effective in reducing the risk of osteoporosis among women of all age group. Health education and promotion toward osteoporosis prevention can significantly contribute in reducing the morbidity of osteoporosis. (author)

  14. Evaluating The Risk Of Osteoporosis Through Bone Mass Density.

    Science.gov (United States)

    Sayed, Sayeeda Amber; Khaliq, Asif; Mahmood, Ashar

    2016-01-01

    Osteoporosis is a bone disorder, characterized by loss of bone mass density. Osteoporosis affects more than 30% of post-menopausal women. Osteoporosis is often associated with restricted body movement, pain and joint deformities. Early identification and early intervention can help in reducing these complications. The primary objective of this study was to estimate the burden of Osteoporosis in Urban setting of Sindh among women of different age groups and to access the effect of different protective measures that can reduce the risk of Osteoporosis. In this study, 500 women's of 3 major cities of Sindh were approached by non-probability convenience sampling technique. Women bearing age 20 years or more were included. Women who fall under inclusion criteria were screened for BMD (Bone mineral density) test and were classified as Healthy, Osteopenic and Osteoporotic based on their T-score. The association of different protective measures and risk of osteoporosis was assessed by prevalence relative risk (PRR). The result of this study indicate that the burden of Osteoporosis is very high among the women of Sindh, only 17.4% (84) women were found to have normal BMD score. The life style of majority of women was sedentary. The PRR calculated for Exposure to sunlight, regular exercise, and use of nutritional supplement was 12.5, 5.19 and 2.72 folds respectively. The results of study reveal that exposure to sunlight, regular physical exercise and use of nutritional supplements found to be effective in reducing the risk of osteoporosis among women of all age group. Health education and promotion toward osteoporosis prevention can significantly contribute in reducing the morbidity of osteoporosis.

  15. Evaluation of methods for MR imaging of human right ventricular heart volumes and mass

    International Nuclear Information System (INIS)

    Jauhiainen, T.; Jaervinen, V.M.; Hekali, P.E.

    2002-01-01

    Purpose: To assess the utility of two different imaging directions in the evaluation of human right ventricular (RV) heart volumes and mass with MR imaging; to compare breath-hold vs. non-breath-hold imaging in volume analysis; and to compare turbo inversion recovery imaging (TIR) with gradient echo imaging in RV mass measurement. Material and Methods: We examined 12 healthy volunteers (age 27-59 years). Breath-hold gradient echo MR imaging was performed in two imaging planes: 1) perpendicular to the RV inflow tract (RVIT view), and 2) in the transaxial view (TA view). The imaging was repeated in the TA view while the subjects were breathing freely. To analyze RV mass using TIR images, the RV was again imaged at end-diastole using the two views. The RV end-diastolic cavity (RVEDV) and muscle volume as well as end-systolic cavity volume (RVESV) were determined with the method of discs. All measurements were done blindly twice to assess repeatability of image analysis. To assess reproducibility of the measurements, 6 of the subjects were imaged twice at an interval of 5-9 weeks. Results: RVEDV averaged 133.2 ml, RVESV 61.5 ml and the RVmass 46.2 g in the RVIT view and 119.9 ml, 56.9 ml and 38.3 g in the TA view, respectively. The volumes obtained with breath-holding were slightly but not significantly smaller than the volumes obtained during normal breathing. There were no marked differences in the RV muscle mass obtained with gradient echo imaging compared to TIR imaging in either views. Repeatability of volume analysis was better in TA than RVIT view: the mean differences were 0.7±4.0 ml and 5.4±14.0 ml in end-diastole and 1.6±3.1 ml and 1.5±13.9 ml in end-systole, respectively. Repeatability of mass analysis was good in both TIR and cine images in the RVIT view but slightly better in TIR images: 0.5±2.4 g compared to 0.8±2.9 g in cine images. Reproducibility of imaging was good, mean differences for RVEDV and RVESV were 1.0±4.8 ml and 0.8±2.8 ml

  16. Measuring oxygen yields of a thermal conversion/elemental analyzer-isotope ratio mass spectrometer for organic and inorganic materials through injection of CO.

    Science.gov (United States)

    Yin, Xijie; Chen, Zhigang

    2014-12-01

    The thermal conversion/elemental analyzer-isotope ratio mass spectrometer (TC/EA-IRMS) is widely used to measure the δ(18) O value of various substances. A premise for accurate δ(18) O measurement is that the oxygen in the sample can be converted into carbon monoxide (CO) quantitatively or at least proportionally. Therefore, a precise method to determine the oxygen yield of TC/EA-IRMS measurements is needed. Most studies have used the CO peak area obtained from a known amount of a solid reference material (for example, benzoic acid) to calibrate the oxygen yield of the sample. Although it was assumed that the oxygen yield of the solid reference material is 100%, no direct evidence has been provided. As CO is the analyte gas for δ(18) O measurement by IRMS, in this study, we use a six-port valve to inject CO gas into the TC/EA. The CO is carried to the IRMS by the He carrier gas and the CO peak area is measured by the IRMS. The CO peak area thus obtained from a known amount of the injected CO is used to calibrate the oxygen yield of the sample. The oxygen yields of commonly used organic and inorganic reference materials such as benzoic acid (C6 H5 COOH), silver phosphate (Ag3 PO4 ), calcium carbonate (CaCO3 ) and silicon dioxide (SiO2 ) are investigated at different reactor temperatures and sample sizes. We obtained excellent linear correlation between the peak area for the injected CO and its oxygen atom amount. C6 H5 COOH has the highest oxygen yield, followed by Ag3 PO4 , CaCO3 and SiO2 . The oxygen yields of TC/EA-IRMS are less than 100% for both organic and inorganic substances, but the yields are relatively stable at the specified reactor temperature and for a given quantity of sample. Copyright © 2014 John Wiley & Sons, Ltd.

  17. Different conformational dynamics of β-arrestin1 and β-arrestin2 analyzed by hydrogen/deuterium exchange mass spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Youngjoo; Kim, Dong Kyun [School of Pharmacy, Sungkyunkwan University, Suwon (Korea, Republic of); Seo, Min-Duk [College of Pharmacy & Department of Molecular Science and Technology, Ajou University, Suwon (Korea, Republic of); Kim, Kyeong-Man [College of Pharmacy, Chonnam National University, Gwang-Ju (Korea, Republic of); Chung, Ka Young, E-mail: kychung2@skku.edu [School of Pharmacy, Sungkyunkwan University, Suwon (Korea, Republic of)

    2015-01-30

    Highlights: • The conformational dynamics of β-arrestin1 or β-arrestin2 were analyzed by HDX-MS. • β-Strands II through IV were more dynamic in β-arrestin2 than in β-arrestin1. • The middle loop was less dynamic in β-arrestin2 than in β-arrestin1. • Upon pre-activation by the R169E mutation, β-arrestins became more dynamic. • Pre-activation affected a wider region of β-arrestin1 compared to β-arrestin2. - Abstract: Arrestins have important roles in G protein-coupled receptor (GPCR) signaling including desensitization of GPCRs and G protein-independent signaling. There have been four arrestins identified: arrestin1, arrestin2 (e.g. β-arrestin1), arrestin3 (e.g. β-arrestin2), and arrestin4. β-Arrestin1 and β-arrestin2 are ubiquitously expressed and regulate a broad range of GPCRs, while arrestin1 and arrestin4 are expressed in the visual system. Although the functions of β-arrestin1 and β-arrestin2 widely overlap, β-arrestin2 has broader receptor selectivity, and a few studies have suggested that β-arrestin1 and β-arrestin2 have distinct cellular functions. Here, we compared the conformational dynamics of β-arrestin1 and β-arrestin2 by hydrogen/deuterium exchange mass spectrometry (HDX-MS). We also used the R169E mutant as a pre-activation model system. HDX-MS data revealed that β-strands II through IV were more dynamic in β-arrestin2 in the basal state, while the middle loop was more dynamic in β-arrestin1. With pre-activation, both β-arrestin1 and β-arrestin2 became more flexible, but broader regions of β-arrestin1 became flexible compared to β-arrestin2. The conformational differences between β-arrestin1 and β-arrestin2 in both the basal and pre-activated states might determine their different receptor selectivities and different cellular functions.

  18. Use of on-line supercritical fluid extraction-supercritical fluid chromatography/tandem mass spectrometry to analyze disease biomarkers in dried serum spots compared with serum analysis using liquid chromatography/tandem mass spectrometry.

    Science.gov (United States)

    Suzuki, Makoto; Nishiumi, Shin; Kobayashi, Takashi; Sakai, Arata; Iwata, Yosuke; Uchikata, Takato; Izumi, Yoshihiro; Azuma, Takeshi; Bamba, Takeshi; Yoshida, Masaru

    2017-05-30

    The analytical stability and throughput of biomarker assays based on dried serum spots (DSS) are strongly dependent on the extraction process and determination method. In the present study, an on-line system based on supercritical fluid extraction-supercritical fluid chromatography coupled with tandem mass spectrometry (SFE-SFC/MS/MS) was established for analyzing the levels of disease biomarkers in DSS. The chromatographic conditions were investigated using the ODS-EP, diol, and SIL-100A columns. Then, we optimized the SFE-SFC/MS/MS method using the diol column, focusing on candidate biomarkers of oral, colorectal, and pancreatic cancer that were identified using liquid chromatography (LC)/MS/MS. By using this system, four hydrophilic metabolites and 17 hydrophobic metabolites were simultaneously detected within 15 min. In an experiment involving clinical samples, PC 16:0-18:2/16:1-18:1 exhibited 93.8% sensitivity and 64.3% specificity, whereas PC 17:1-18:1/17:0-18:2 showed 81.3% sensitivity and 92.9% specificity for detecting oral cancer. In addition, assessments of the creatine levels demonstrated 92.3% sensitivity and 78.6% specificity for detecting colorectal cancer. The results of this study indicate that our method has great potential for clinical diagnosis and would be suitable for large-scale screening. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  19. Limited-sequence magnetic resonance imaging in the evaluation of the ultrasonographically indeterminate pelvic mass

    Energy Technology Data Exchange (ETDEWEB)

    Chang, S.D. [Univ. of British Columbia, Vancouver Hospital and Helath Services Centre, Dept. of Radiology, Vancouver, British Columbia (Canada)]. E-mail: schang@vanhosp.bc.ca; Cooperberg, P.L.; Wong, A.D. [Univ. of British Columbia, St. Paul' s Hospital, Dept. of Radiology, Vancouver, British Columbia (Canada); Llewellyn, P.A. [Lion' s Gate Hospital, Dept. of Radiology, North Vancouver, British Columbia (Canada); Bilbey, J.H. [Royal Inland Hospital, Dept. of Radiology, Kamloops, British Columbia (Canada)

    2004-04-01

    To evaluate the usefulness of limited-sequence magnetic resonance imaging (MRI) in the elucidation of ultrasonographically indeterminate pelvic masses. This study focused only on pelvic masses in which the origin of the mass (uterine v. extrauterine) could not be determined by ultrasonography (US). The origin of a pelvic mass has clinical implications. A mass arising from the uterus is most likely to be a leiomyoma, which is a benign lesion, whereas an extrauterine mass will have a higher likelihood of malignancy and usually requires surgery. Eighty-one female patients whose pelvic mass was of indeterminate origin on US also underwent limited-sequence MRI of the pelvis. Most of the MRI examinations were performed on the same day as the US. Limited-sequence MRI sequences included a quick gradient-echoT{sub 1}-weighted localizer and a fast spin-echoT{sub 2}-weighted sequence. Final diagnoses were established by surgical pathology or by clinical and imaging follow-up. Limited-sequence MRI was helpful in 79 of the 81 cases (98%). Fifty-two of the 81 masses (64%) were leiomyomas. One was a leiomyosarcoma. The extrauterine masses (26/81 [32%]) were identified as 14 ovarian malignancies, 4 endometriomas, 3 dermoids, an ovarian fibroma, an infarcted fibrothecoma, an infarcted hemorrhagic cyst, a sigmoid diverticular abscess and a gastrointestinal stromal tumour of the ileum. In the other 2 cases (2/81 [2%]), the origin of the pelvic mass remained indeterminate. Both of these indeterminate masses showed low signal onT{sub 2}-weighted images and were interpreted as probable leiomyomas. They were not surgically removed but were followed clinically and had a stable course. Limited-sequence MRI is a quick and efficient way to further evaluate ultrasonographically indeterminate pelvic masses. Limited-sequence MRI of the pelvis can suffice, in these cases, without requiring a full MRI examination. (author)

  20. Limited-sequence magnetic resonance imaging in the evaluation of the ultrasonographically indeterminate pelvic mass

    International Nuclear Information System (INIS)

    Chang, S.D.; Cooperberg, P.L.; Wong, A.D.; Llewellyn, P.A.; Bilbey, J.H.

    2004-01-01

    To evaluate the usefulness of limited-sequence magnetic resonance imaging (MRI) in the elucidation of ultrasonographically indeterminate pelvic masses. This study focused only on pelvic masses in which the origin of the mass (uterine v. extrauterine) could not be determined by ultrasonography (US). The origin of a pelvic mass has clinical implications. A mass arising from the uterus is most likely to be a leiomyoma, which is a benign lesion, whereas an extrauterine mass will have a higher likelihood of malignancy and usually requires surgery. Eighty-one female patients whose pelvic mass was of indeterminate origin on US also underwent limited-sequence MRI of the pelvis. Most of the MRI examinations were performed on the same day as the US. Limited-sequence MRI sequences included a quick gradient-echoT 1 -weighted localizer and a fast spin-echoT 2 -weighted sequence. Final diagnoses were established by surgical pathology or by clinical and imaging follow-up. Limited-sequence MRI was helpful in 79 of the 81 cases (98%). Fifty-two of the 81 masses (64%) were leiomyomas. One was a leiomyosarcoma. The extrauterine masses (26/81 [32%]) were identified as 14 ovarian malignancies, 4 endometriomas, 3 dermoids, an ovarian fibroma, an infarcted fibrothecoma, an infarcted hemorrhagic cyst, a sigmoid diverticular abscess and a gastrointestinal stromal tumour of the ileum. In the other 2 cases (2/81 [2%]), the origin of the pelvic mass remained indeterminate. Both of these indeterminate masses showed low signal onT 2 -weighted images and were interpreted as probable leiomyomas. They were not surgically removed but were followed clinically and had a stable course. Limited-sequence MRI is a quick and efficient way to further evaluate ultrasonographically indeterminate pelvic masses. Limited-sequence MRI of the pelvis can suffice, in these cases, without requiring a full MRI examination. (author)

  1. Technical assessment of air quality measuring analyzers; Evaluation technique des analyseurs de mesure de la qualite de l`air

    Energy Technology Data Exchange (ETDEWEB)

    Tatry, V. [Laboratoire de mesures a l`air ambiant, Dept. Mesures et Analyses, INERIS, (France)

    1996-12-31

    Air quality measuring analyzers are assessed in order to verify their measuring performance and to examine their aptitude to field measurements. For ensuring such assessment, the INERIS institute (France) disposes of three climatic enclosures, gas mixture emission systems and data acquisition systems. The assessment methodology is presented together with the various possible results: response time, linearity and limits determination, calibration studies, thresholds, drifts, hysteresis, physical detrimental effects, etc. Applications such as analyzers for one or more pollutants in ambient air and at the emission source (portable multi-gas analyzers) are presented, together with their results

  2. Radiometric analyzer

    International Nuclear Information System (INIS)

    Arima, S.; Oda, M.; Miyashita, K.; Takada, M.

    1977-01-01

    A radiometric analyzer for measuring the characteristic values of a sample by radiation includes a humer of radiation measuring subsystems having different ratios of sensitivities to the elements of the sample and linearizing circuits having inverse function characteristics of calibration functions which correspond to the radiation measuring subsystems. A weighing adder operates a desirable linear combination of the outputs of the linearizing circuits. Operators for operating between two or more different linear combinations are included

  3. The role of three-dimensional imaging in evaluation of the sinonasal mass

    Energy Technology Data Exchange (ETDEWEB)

    Shim, Sue Yon; Sung, Ki Joon; Kim, Young Ju; Hong, In Soo; Kim, Myung Soon; Oh, Jin Hwan; Paik, Seog In [Yonsei Univ. College of Medicine, Wonju (Korea, Republic of)

    1996-01-01

    To investigate the role of 3D imaging in the sinonasal mass. Twenty patients with sinonasal mass(squamous cell carcinoma[n=6], spindle cell carcinoma[n=1], angiomatous polyp[n=1], giant cell reparative granuloma[n=1], non-Hodgkin's lymphjoma[n=1], melanoma[n=1], angiofibroma[n=1], inverted papilloma[n=1]) were studied with spiral CT. Reconstruction of surface rendered 3D images and segmentations were performed and compared with the 2D image. The 3D images enabled easy understanding of the characteristics of the mass in 12 casese. The 3D images displayed pathway of tumor extension in 5 cases and were helpful in assessing the primary site of the mass in 3 cases. In two cases with encasement of ICA by the mass, assessment of relationship between the mass and vessels were possible through the segmentation. The 3D image, as an adjunct to the 2D image, can help to evaluate the virtual appearance of bony change, the degree of extension of mass, the spreading route, the evaluation of origin site. It also provides valuable 3-dimensional conception of the mass, especially for the surgeon.

  4. EVALUATION OF A PORTABLE FOURIER TRANSFORM INFRARED GAS ANALYZER FOR MEASUREMENTS OF AIR TOXICS IN POLLUTION PREVENTION RESEARCH

    Science.gov (United States)

    A portable Fourier transform infrared gas analyzer with a photoacoustic detector performed reliably during pollution prevention research at two industrial facilities. It exhibited good agreement (within approximately 6%) with other analytical instruments (dispersive infrared and ...

  5. Performance of the linear ion trap Orbitrap mass analyzer for qualitative and quantitative analysis of drugs of abuse and relevant metabolites in sewage water

    NARCIS (Netherlands)

    Bijlsma, L.; Emke, E.; Hernández, F.; de Voogt, P.

    2013-01-01

    This work illustrates the potential of liquid chromatography coupled to a hybrid linear ion trap Fourier Transform Orbitrap mass spectrometer for the simultaneous identification and quantification of 24 drugs of abuse and relevant metabolites in sewage water. The developed methodology consisted of

  6. Indoor fire in a nursing home : evaluation of the medical response to a mass casualty incident based on a standardized protocol

    NARCIS (Netherlands)

    Koning, S. W.; Ellerbroek, P. M.; Leenen, L. P. H.

    This retrospective study reports the outcome of a mass casualty incident (MCI) caused by a fire in a nursing home. Data from the medical charts and registration system of the Major Incident Hospital (MIH) and ambulance service were analyzed. The evaluation reports from the MIH and an independent

  7. Clinical relevance of the discrepancy in phenylalanine concentrations analyzed using tandem mass spectrometry compared with ion-exchange chromatography in phenylketonuria

    Directory of Open Access Journals (Sweden)

    Bridget M. Stroup

    2016-03-01

    Conclusion: Use of DBS analyzed using MS/MS to monitor blood phe concentrations in individuals with PKU yields significantly lower phe levels compared to plasma phe levels analyzed using IEC. Optimization of current testing methodologies for measuring phe in DBS, along with patient education regarding the appropriate technique for spotting blood on filter paper is needed to improve the accuracy of using DBS to measure phe concentrations in PKU management.

  8. MALDI Mass Spectrometry Imaging for Evaluation of Therapeutics in Colorectal Tumor Organoids

    Science.gov (United States)

    Liu, Xin; Flinders, Colin; Mumenthaler, Shannon M.; Hummon, Amanda B.

    2018-03-01

    Patient-derived colorectal tumor organoids (CTOs) closely recapitulate the complex morphological, phenotypic, and genetic features observed in in vivo tumors. Therefore, evaluation of drug distribution and metabolism in this model system can provide valuable information to predict the clinical outcome of a therapeutic response in individual patients. In this report, we applied matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) to examine the spatial distribution of the drug irinotecan and its metabolites in CTOs from two patients. Irinotecan is a prodrug and is often prescribed as part of therapeutic regimes for patients with advanced colorectal cancer. Irinotecan shows a time-dependent and concentration-dependent permeability and metabolism in the CTOs. More interestingly, the active metabolite SN-38 does not co-localize well with the parent drug irinotecan and the inactive metabolite SN-38G. The phenotypic effect of irinotecan metabolism was also confirmed by a viability study showing significantly reduced proliferation in the drug treated CTOs. MALDI-MSI can be used to investigate various pharmaceutical compounds in CTOs derived from different patients. By analyzing multiple CTOs from a patient, this method could be used to predict patient-specific drug responses and help to improve personalized dosing regimens. [Figure not available: see fulltext.

  9. Contamination Analyzer

    Science.gov (United States)

    1994-01-01

    Measurement of the total organic carbon content in water is important in assessing contamination levels in high purity water for power generation, pharmaceutical production and electronics manufacture. Even trace levels of organic compounds can cause defects in manufactured products. The Sievers Model 800 Total Organic Carbon (TOC) Analyzer, based on technology developed for the Space Station, uses a strong chemical oxidizing agent and ultraviolet light to convert organic compounds in water to carbon dioxide. After ionizing the carbon dioxide, the amount of ions is determined by measuring the conductivity of the deionized water. The new technique is highly sensitive, does not require compressed gas, and maintenance is minimal.

  10. Fetal MRI evaluation of an intracranial mass: in utero evolution of hemorrhage

    International Nuclear Information System (INIS)

    Emamian, Seyed A.; Bulas, Dorothy I.; Vezina, Gilbert L.; Dubovsky, Elizabeth C.; Cogan, Phillip

    2002-01-01

    The role of MRI in the evaluation of fetal abnormalities is still under evaluation. We describe a case of an intracranial mass that was initially identified by prenatal ultrasound and was further evaluated by MRI. Ultimately, the findings were most consistent with hematoma secondary to an underlying dural malformation with spontaneous involution. The advantages of fetal MRI in the assessment and management of this abnormality will be discussed. (orig.)

  11. Fetal MRI evaluation of an intracranial mass: in utero evolution of hemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    Emamian, Seyed A.; Bulas, Dorothy I.; Vezina, Gilbert L.; Dubovsky, Elizabeth C. [Department of Diagnostic Imaging and Radiology, Children' s National Medical Center, 111 Michigan Avenue, NW, Washington, DC 20010 (United States); Cogan, Phillip [Department of Neurosurgery, Children' s National Medical Center, George Washington University,Washington, DC (United States)

    2002-08-01

    The role of MRI in the evaluation of fetal abnormalities is still under evaluation. We describe a case of an intracranial mass that was initially identified by prenatal ultrasound and was further evaluated by MRI. Ultimately, the findings were most consistent with hematoma secondary to an underlying dural malformation with spontaneous involution. The advantages of fetal MRI in the assessment and management of this abnormality will be discussed. (orig.)

  12. Three-dimensional power Doppler ultrasonography in evaluation of adnexal masses

    Directory of Open Access Journals (Sweden)

    Ahmed M. Abbas

    2017-12-01

    The introduction of 3DPD has opened the possibility to characterize microvasculature of the adnexal masses and objectively assess tumor vascularization. 3DPD allows also an objective measurement of vascularity of a given region of interest by estimating 3 vascular indices (vascularization index [VI], flow index [FI], and vascularization-flow index [VFI] within such region. The aim of this review article is to evaluate the role of 3DPD in the assessment of adnexal masses vascularity, its ability to discriminate benign masses from malignant ones.

  13. Evaluation of point-of-care analyzers' ability to reduce bias in conductivity-based hematocrit measurement during cardiopulmonary bypass

    NARCIS (Netherlands)

    Teerenstra, S.; Steinfelder-Visscher, J.; Gunnewiek, J.K.; Weerwind, P.W.

    2014-01-01

    Most point-of-care testing analyzers use the conductivity method to measure hematocrit (hct). During open-heart surgery, blood-conductivity is influenced by shifts in electrolyte and colloid concentrations caused by infusion media used, and this may lead to considerable bias in the hct measurement.

  14. Evaluation of a point-of-care blood analyzer and determination of reference ranges for blood parameters in rockfish.

    Science.gov (United States)

    Harrenstien, Lisa A; Tornquist, Susan J; Miller-Morgan, Timothy J; Fodness, Brian G; Clifford, Kevin E

    2005-01-15

    To compare values of blood parameters in rockfish obtained by use of a point-of-care portable blood analyzer with values determined by a veterinary diagnostic laboratory, calculate reference ranges for various blood parameters in black rockfish, and compare values of blood parameters in clinically normal fish with those of fish with clinical abnormalities. Prospective study. 41 captive adult black rockfish (Sebastes melanops) and 4 captive adult blue rockfish (Sebastes mystinus). Rockfish were anesthetized with tricaine methanesulfonate for collection of blood samples. Heparinized blood samples were immediately analyzed with a point-of-care analyzer. Blood sodium, potassium, chloride, urea nitrogen, and glucose concentrations; Hct; pH; partial pressure of carbon dioxide; total carbon dioxide concentration; bicarbonate concentration; base excess; and hemoglobin concentration were determined. A microhematocrit technique was used to determine PCV, and a refractometer was used to estimate total plasma protein concentration. Paired heparinized blood samples were transported to a veterinary diagnostic laboratory for analyses. Data obtained with the point-of-care analyzer were reproducible; however, values for most blood parameters were significantly different from those obtained by the veterinary diagnostic laboratory. Fish with poor body condition had several blood parameter values that were lower than corresponding values in clinically normal fish. Point-of-care blood analyses may prove useful in rockfish. Point-of-care data for a large number of clinically normal fish must be obtained for reference ranges to be calculated, and further assessments of clinically abnormal fish are necessary to determine the relevance of the data.

  15. An Evaluation of Statistical Methods for Analyzing Follow-Up Gaussian Laboratory Data with a Lower Quantification Limit

    NARCIS (Netherlands)

    Karon, John M.; Wiegand, Ryan E.; van de Wijgert, Janneke H.; Kilmarx, Peter H.

    2015-01-01

    Laboratory data with a lower quantification limit (censored data) are sometimes analyzed by replacing non-quantifiable values with a single value equal to or less than the quantification limit, yielding possibly biased point estimates and variance estimates that are too small. Motivated by a

  16. Direct gas injection method: A simple modification to an elemental analyzer/isotope ratio mass spectrometer for stable isotope analysis of N and C from N2O and CO2 gases in nanomolar concentrations

    Science.gov (United States)

    A simple modification to the Elemental Analyzer coupled to Isotope Ratio Mass-Spectrometer (EA-IRMS) setup is described. This modification allows the users to measure nitrous oxide (N2O) and carbon dioxide (CO2) by injecting the gases directly into an online injector placed befor...

  17. An evaluation of gastric mass survey from the standpoint of expectation of life

    International Nuclear Information System (INIS)

    Yokoyama, Michio; Kitabatake, Takashi.

    1977-01-01

    The authors reexamined the evaluation of mass gastric survey, which had previously been reported by them, from the standpoint of expectation of life and advocated new theories, the number of years of expected lifesaving and the rate of loss and gain of years. Comparison between the new evaluation and the pre-existing evaluation produces the following differences. (1) The number of years of expected lifesaving increases rapidly from the 50s to reach a peak in the 60s and to decrease from the 70s. This is more realistic and reasonable than the pre-existing method by which the higher the age, the more is gain increased. (2) The rate of loss and gain of mass gastric survey increases in each age group. In other words, the value of mass gastric survey is evaluated more highly. While the importance of mass gastric survey has recently been recognized, the number of examinees increasing, injury due to exposure to radiation has become a serious problem. Therefore, it was thought to be important to perform mass gastric survey efficiently on subjects limited based on the theory investigated from both aspects of advantage and disadvantage. (Chiba, N.)

  18. Application of ultraperformance liquid chromatography/mass spectrometry-based metabonomic techniques to analyze the joint toxic action of long-term low-level exposure to a mixture of organophosphate pesticides on rat urine profile.

    Science.gov (United States)

    Du, Longfei; Wang, Hong; Xu, Wei; Zeng, Yan; Hou, Yurong; Zhang, Yuqiu; Zhao, Xiujuan; Sun, Changhao

    2013-07-01

    In previously published articles, we evaluated the toxicity of four organophosphate (OP) pesticides (dichlorvos, dimethoate, acephate, and phorate) to rats using metabonomic technology at their corresponding no observed adverse effect level (NOAEL). Results show that a single pesticide elicits no toxic response. This study aimed to determine whether chronic exposure to a mixture of the above four pesticides (at their corresponding NOAEL) can lead to joint toxic action in rats using the same technology. Pesticides were administered daily to rats through drinking water for 24 weeks. The above mixture of the four pesticides showed joint toxic action at the NOAEL of each pesticide. The metabonomic profiles of rats urine were analyzed by ultraperformance liquid chromatography/mass spectrometry. The 16 metabolites statistically significantly changed in all treated groups compared with the control group. Dimethylphosphate and dimethyldithiophosphate exclusively detected in all treated groups can be used as early, sensitive biomarkers for exposure to a mixture of the OP pesticides. Moreover, exposure to the OP pesticides resulted in increased 7-methylguanine, ribothymidine, cholic acid, 4-pyridoxic acid, kynurenine, and indoxyl sulfate levels, as well as decreased hippuric acid, creatinine, uric acid, gentisic acid, C18-dihydrosphingosine, phytosphingosine, suberic acid, and citric acid. The results indicated that a mixture of OP pesticides induced DNA damage and oxidative stress, disturbed the metabolism of lipids, and interfered with the tricarboxylic acid cycle. Ensuring food safety requires not only the toxicology test data of each pesticide for the calculation of the acceptable daily intake but also the joint toxic action.

  19. Identification of irradiation treatment in processed food. Pt. 2. Evaluation of a SPE-method for analyzing irradiation induced hydrocarbons

    International Nuclear Information System (INIS)

    Hartmann, M.; Ammon, J.; Berg, H.

    1996-01-01

    This paper deals with a solid phase extraction (SPE) method for the isolation of irradiation induced hydrocarbons which can replace the column chromatography described in the paragraph 35 LMBG (German Food Law) procedure L06.00-37. Using this new method, only a tenth of solvents and column material is necessary. The SPE method was a good as LC-LC-GC/FID or LC-LC-GC/MS in analyzing new or complex matrices like paprika or salmon. Additionally, it is fast, cheap and easy to perform. As far as we know, the detection of irradiation traetment in paprika powder by analyzing irradiation induced hydrocarbons has not been described before. The new method is a good alternative for the commonly used thermoluminescence procedure. (orig.) [de

  20. Evaluation of the lithology contents and types of clay minerals using downhole spectral analyzer of natural gamma radiation

    International Nuclear Information System (INIS)

    Zivanov, M.; Savicic, M.; Grbovic, G.

    1992-01-01

    The microprocessor downhole spectrum analyzer of natural gamma radiation is an important part of the new generation of geophysical well logging systems. This instrument produces complete energy spectra of the penetrated formations. here physical principles of logging are shown. based on the logging results from one of the wells complex lithology was identified, together with shale contents in the formation and types of clay and minerals. (author)

  1. Intrahepatic and hilar mass-forming cholangiocarcinoma: Qualitative and quantitative evaluation with diffusion-weighted MR imaging.

    Science.gov (United States)

    Fattach, Hassan El; Dohan, Anthony; Guerrache, Youcef; Dautry, Raphael; Boudiaf, Mourad; Hoeffel, Christine; Soyer, Philippe

    2015-08-01

    To qualitatively and quantitatively analyze the presentation of intrahepatic and hilar mass-forming cholangiocarcinoma with diffusion-weighted magnetic resonance imaging (DW-MRI). Twenty-eight patients with histopathologically proven mass-forming cholangiocarcinoma (hilar, n=17; intrahepatic, n=11) underwent hepatic DW-MRI at 1.5-T using free-breathing acquisition and three b-values (0,400,800s/mm(2)). Cholangiocarcinomas were evaluated qualitatively using visual analysis of DW-MR images and quantitatively with conventional ADC and normalized ADC measurements using liver and spleen as reference organs. All cholangiocarcinomas (28/28; 100%) were visible on DW-MR images. DW-MRI yielded best conspicuity of cholangiocarcinomas than the other MRI sequences (Philar cholangiocarcinomas. The use of normalized ADC using the liver as reference organ resulted in the most restricted distribution of ADC values of cholangiocarcinomas (variation coefficient=16.6%). There is a trend towards a common appearance of intrahepatic and hilar mass-forming cholangiocarcinomas on DW-MRI but variations may be observed. Familiarity with these variations may improve the diagnosis of mass-forming cholangiocarcinoma. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  2. Analyzing powers and isotope ratios for the natAg(rvec p, intermediate-mass fragment) reaction at 200 MeV

    International Nuclear Information System (INIS)

    Renshaw, E.; Yennello, S.J.; Kwiatkowski, K.; Planeta, R.; Woo, L.W.; Viola, V.E.

    1991-01-01

    Analyzing powers and isotope ratios have been measured for ejectiles with Z≤7 emitted at forward angles in the 200-MeV rvec p+ nat Ag reaction. The observed analyzing powers are consistent with zero, and thus do not provide evidence for a significant contribution from cluster knockout, or similar direct formation mechanisms. Fragment kinetic-energy spectra above the Coulomb peak are compared with a coalescence calculation. The isotopic composition of the elemental kinetic-energy spectra is found to favor N/Z≥1 nuclei for fragment energies near the exit-channel Coulomb energy, whereas species with N/Z≤1 are more abundant in the high-energy spectral tails. This behavior is consistent with the predictions of an accreting source calculation

  3. Evaluation of a novel automated water analyzer for continuous monitoring of toxicity and chemical parameters in municipal water supply.

    Science.gov (United States)

    Bodini, Sergio F; Malizia, Marzio; Tortelli, Annalisa; Sanfilippo, Luca; Zhou, Xingpeng; Arosio, Roberta; Bernasconi, Marzia; Di Lucia, Stefano; Manenti, Angela; Moscetta, Pompeo

    2018-08-15

    A novel tool, the DAMTA analyzer (Device for Analytical Monitoring and Toxicity Assessment), designed for fully automated toxicity measurements based on luminescent bacteria as well as for concomitant determination of chemical parameters, was developed and field-tested. The instrument is a robotic water analyzer equipped with a luminometer and a spectrophotometer, integrated on a thermostated reaction plate which contains a movable carousel with 80 cuvettes. Acute toxicity is measured on-line using a wild type Photobacterium phosphoreum strain with measurable bioluminescence and unaltered sensitivity to toxicants lasting up to ten days. The EC50 values of reference compounds tested were consistent with A. fischeri and P. phosphoreum international standards and comparable to previously published data. Concurrently, a laboratory trial demonstrated the feasibility of use of the analyzer for the determination of nutrients and metals in parallel to the toxicity measurements. In a prolonged test, the system was installed only in toxicity mode at the premises of the World Fair "Expo Milano-2015″, a high security site to ensure the quality of the supplied drinking water. The monitoring program lasted for six months during which ca. 2400 toxicity tests were carried out; the results indicated a mean non-toxic outcome of -5.5 ± 6.2%. In order to warrant the system's robustness in detecting toxic substances, Zn was measured daily with highly reproducible inhibition results, 70.8 ± 13.6%. These results assure that this novel toxicity monitor can be used as an early warning system for protection of drinking water sources from emergencies involving low probability/high impact contamination events in source water or treated water. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Evaluation of a Fully Automated Analyzer for Rapid Measurement of Water Vapor Sorption Isotherms for Applications in Soil Science

    DEFF Research Database (Denmark)

    Arthur, Emmanuel; Tuller, Markus; Moldrup, Per

    2014-01-01

    The characterization and description of important soil processes such as water vapor transport, volatilization of pesticides, and hysteresis require accurate means for measuring the soil water characteristic (SWC) at low water potentials. Until recently, measurement of the SWC at low water...... potentials was constrained by hydraulic decoupling and long equilibration times when pressure plates or single-point, chilled-mirror instruments were used. A new, fully automated Vapor Sorption Analyzer (VSA) helps to overcome these challenges and allows faster measurement of highly detailed water vapor...

  5. Evaluation of the URIT-2900 automated hematology analyzer for screening of thalassemia and hemoglobinopathies in Southeast Asian populations.

    Science.gov (United States)

    Karnpean, Rossarin; Pansuwan, Anupong; Fucharoen, Goonnapa; Fucharoen, Supan

    2011-07-01

    The effectiveness of the URIT-2900 Hematology Analyzer for screening of hemoglobinopathies commonly found in Southeast Asian populations was examined. Appropriate cut-off values of MCV and MCH for screening of α(0) and β thalassemias were derived from the receiver operator characteristic curve conducted initially on 279 subjects with various thalassemia genotypes. Validation was performed additionally in a cohort of another unrelated 313 subjects. The best cut off values of MCV and MCH were found to be 78fL and 27pg, respectively. Using these cut off values in combination with the dichlorophenolindophenol test in screening of α(0) thalassemia, β thalassemia and Hb E in a cohort study revealed 100% sensitivity, 79.6% specificity, 80.0% positive predictive value and 100% negative predictive value. The combined blood cell counting using the URIT-2900 Automated Hematology Analyzer and dichlorophenolindophenol test is suitable for population screening of thalassemia and hemoglobinopathies in Southeast Asia. Copyright © 2011 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  6. Impact of collection conditions on the metabolite content of human urine samples as analyzed by liquid chromatography coupled to mass spectrometry and nuclear magnetic resonance spectroscopy

    OpenAIRE

    Roux, Aurélie; Thévenot, Etienne A.; Seguin, François; Olivier, Marie-Françoise; Junot, Christophe

    2014-01-01

    There is a lack of comprehensive studies documenting the impact of sample collection conditions on metabolic composition of human urine. To address this issue, two experiments were performed at a 3-month interval, in which midstream urine samples from healthy individuals were collected, pooled, divided into several aliquots and kept under specific conditions (room temperature, 4 °C, with or without preservative) up to 72 h before storage at −80 °C. Samples were analyzed by high-performance li...

  7. Pericardial cyst with atypical location: densimetric evaluation of mediastinal masses by computerized tomography

    International Nuclear Information System (INIS)

    Franquet, T.; Jiminez, F.J.; Eguizabal, C.; Bescos, J.M.

    1991-01-01

    We present a case of pericardial cyst with atypical location. CT has been very usefull for densitometric evaluation of mediastinal masses. Using a combination of cross-section diagnostic methods and fine-needle aspiration (FNA), we can carry out accurate diagnoses of cystic lesions located in uncommom sites. (Author)

  8. Evaluation of body mass index and plasma lipid profile in dogs ...

    African Journals Online (AJOL)

    This study evaluated the body mass index (BMI), plasma lipid profile and gait assessment score (GAS) in dogs. Body weights (BW), height (H) at shoulder and waist circumference (WC) were obtained from fifty client-owned dogs of both sexes to determine the BMI. In addition, body condition score (BCS) and GAS were ...

  9. Evaluation of body mass index and plasma lipid profile in Boerboel ...

    African Journals Online (AJOL)

    This study evaluated the body mass index (BMI) and plasma lipid profile in Boerboel dogs. Body weights (BW), height (H) at shoulder and waist circumference (WC) were obtained from fifty-three Boerboels to determine the BMI while, body condition score (BCS) was determined subjectively. Also 5mls of blood was obtained ...

  10. An evaluation of the role of the mass media in conflict management ...

    African Journals Online (AJOL)

    An evaluation of the role of the mass media in conflict management: The Niger ... ups and downs to the public within the ambit of social responsibility theory of the ... Thus, blowing mere misunderstanding and misconception of issues from the ...

  11. Analyzing powers and interference between one- and multi-step processes in (polarized p, t) reactions on medium-mass vibrational nuclei

    International Nuclear Information System (INIS)

    Yagi, K.; Kunori, S.; Aoki, Y.; Nagano, K.; Tagishi, Y.

    1978-01-01

    A neutron-number (N) dependence of analyzing powers A (theta) has been observed for the first time in (polarized p, t) reactions leading to the quadrupole vibrational states (2 1 + ) in 98 Ru, sup(102,108)Pd, 114 Cd, 116 Sn, and sup(120,126)Te. Although analyzing powers for the ground-state transitions A(theta,0 sub(g)sup(+)) are very similar to each other, those for the 2 1 + transitions A(theta,2 1 + ) for the nuclei belonging to the beginning of the N = 50 - 82 shell are markedly different, having almost opposite signs, from A(theta,2 1 + ) for nuclei belonging to the latter half of the major shell. The difference is explained as a result of a sign change of the interference between one- and inelastic multi-step processes in two-neutron pickup reactions. Nuclear structure effects on such an interference are discussed on the basis of the microscopic description of collective quadrupole oscillation of nuclei. (author)

  12. Evaluation of supercritical fluid chromatography coupled to tandem mass spectrometry for pesticide residues in food.

    Science.gov (United States)

    Cutillas, Víctor; Galera, María Martínez; Rajski, Łukasz; Fernández-Alba, Amadeo R

    2018-04-13

    Supercritical fluid chromatography coupled to triple quadrupole mass spectrometry has been evaluated for pesticide residues in food. In order to check its advantages and limitations it was developed a method to identify and quantify 164 pesticides in three different matrices (tomato, orange and leek). A carbon dioxide gradient with methanol (containing 1 mM ammonium formate) was used allowing a flow rate of 1.5 mL/min that made the total run time of 12 min without any problem of overpressure. Addition of a post column flow 150 μL/min of Methanol with ammonium formate/formic acid was necessary to improve the ionization. The matrix effect study revealed that the percentages of pesticides with irrelevant matrix effect (suppression lower than 20%) was 99% in tomato, 87% in orange and 62% in leek, whereas significant suppression (higher than 50%) was not found in tomato and only 1% of the compounds in orange and 3% in leek.These results compare favorably with that typically obtained in LC-MS/MS. The absence of water in the mobile phase, also provided some important advantages regarding LC-MS/MS as (i) higher retention of polar compounds in the column, which elute with high sensitivity and good peak shape and (ii) a general increase of the sensitivity of the analysis, consequence of the high ionization and ion extraction efficiency. Pesticides evaluated were identified following the SANTE/11813/2017. At the spiking concentration of 5 μg/kg, 98% of the pesticides were identified in tomato, 98% in orange and 94% in leek, whereas for the concentration of 10 μg/kg all the compounds were identified in tomato and only spiromesifen was not identified in orange and leek. At the concentration of 20 μg/kg, spiromesifen was also identified in these two matrices. The linearity and reproducibility of the method were evaluated with results which guarantee high quality in the analytical measurements. Even though only 2 μL of final extract were injected, the

  13. Analyzing powers for (p,t) transitions to the first-excited 2+ states of medium-mass nuclei and nuclear collective motions

    International Nuclear Information System (INIS)

    Nagano, K.; Aoki, Y.; Kishimoto, T.; Yagi, K.

    1983-01-01

    Vector analyzing powers A(theta) and differential cross sections σ(theta) have been measured, with the use of a polarized proton beam of 22.0 MeV and a magnetic spectrograph, for (p,t) reactions leading to the first-excited 2 + (2 1 + ) states of the following eighteen nuclei of N = 50 - 82: sup(92,94,96)Mo, sup(98,100,102)Ru, sup(102,104,106,108)Pd, sup(110,112,114)Cd, 116 Sn, sup(120,126,128)Te, and 136 Ba. In addition A(theta) and σ(theta) for sup(104,110)Pd(p,t) sup(102,108) Pd(0sub(g) + ,2 1 + ) transitions have been measured at Esub(p) = 52.2 MeV. The experimental results are analyzed in terms of the first- and second-order DWBA including both inelastic two-step processes and sequential transfer (p,d)(d,t) two-step processes. Inter-ference effect between the direct and the two-step processes is found to play an essential role in the (p,t) reactions. A sum-rule method for calculating the (p,d)(d,t) spectroscopic amplitudes has been developed so as to take into account the ground-state correlation in odd-A nuclei. The nuclear-structure wave functions are constructed under the boson expansion method and the quasiparticle random phase approximation (qp RPA) method by using the monopole-pairing, quadrupole-pairing, and QQ forces. The characteristic features of the experimental A(theta) and σ(theta) are better explained in terms of the boson expansion method than in terms of the qp RPA. Dependence of the (p,t) analyzing powers on the static electric quadrupole moment of the 2 1 + state is found to be strong because of the reorientation (anharmonic) effect in the 2 1 + yiedls 2 1 + transfer process. (J.P.N.)

  14. Analyzing Black Hole Super-Radiance Emission of Particles/Energy from a Black Hole as a Gedankenexperiment to Get Bounds on the Mass of a Graviton

    Directory of Open Access Journals (Sweden)

    A. Beckwith

    2014-01-01

    Full Text Available Use of super-radiance in BH physics, so dE/dt<0 specifies conditions for a mass of a graviton being less than or equal to 1065 grams, allows for determing what role additional dimensions may play in removing the datum that massive gravitons lead to 3/4th the bending of light past the planet Mercury. The present document makes a given differentiation between super-radiance in the case of conventional BHs and Braneworld BH super-radiance, which may delineate whether Braneworlds contribute to an admissible massive graviton in terms of removing the usual problem of the 3/4th the bending of light past the planet Mercury which is normally associated with massive gravitons. This leads to a fork in the road between two alternatives with the possibility of needing a multiverse containment of BH structure or embracing what Hawkings wrote up recently, namely, a redo of the event horizon hypothesis as we know it.

  15. Trace elements in free-range hen eggs in the Campania region (Italy) analyzed by inductively coupled plasma mass spectrometry (ICP-MS).

    Science.gov (United States)

    Esposito, Mauro; Cavallo, Stefania; Chiaravalle, Eugenio; Miedico, Oto; Pellicanò, Roberta; Rosato, Guido; Sarnelli, Paolo; Baldi, Loredana

    2016-06-01

    Eggs from hens raised on rural or domestic farms are a good indicator of environmental contamination, as the hens are in close contact with the ground and the air and can therefore accumulate heavy metals and other toxic contaminants from the environment as well as from the diet. In this paper, we report the results of the determination of 19 trace elements (As, Be, Cd, Co, Cr, Cu, Hg, Mo, Mn, Ni, Pb, Sb, Se, Sn, Sr, Tl, U, V, Zn) in 39 hen egg samples collected from domestic poultry farms in the territory dubbed the "Land of fires" in the Campania region (Italy). This area is characterized by environmental problems caused by the illegal dumping of industrial or domestic waste in fields or by roadsides. In some cases, these wastes have been burned, thereby spreading persistent contaminants into the atmosphere. The content of trace elements in whole egg samples was determined by mass spectrometer after a microwave-assisted digestion procedure. Because European legislation does not indicate maximum values of these elements in this foodstuff, the results were compared with the content of trace elements reported in literature for eggs, in particular home-produced eggs, in various countries. In some cases (Cd, Cu, Ni, Mn), the content determined in this study was in line with those reported elsewhere, in other cases (Pb, Cr), lower values were found.

  16. SU-E-P-36: Evaluation of MLC Positioning Errors in Dynamic IMRT Treatments by Analyzing Dynalog Files

    International Nuclear Information System (INIS)

    Olasolo, J; Pellejero, S; Gracia, M; Gallardo, N; Martin, M; Lozares, S; Maneru, F; Bragado, L; Miquelez, S; Rubio, A

    2015-01-01

    Purpose: To assess the accuracy of MLC positioning in Varian linear accelerator, in dynamic IMRT technique, from the analysis of dynalog files generated by the MLC controller. Methods: In Clinac accelerators (pre-TrueBeam technology), control system has an approximately 50ms delay (one control cycle time). Then, the system compares the measured position to the planned position corresponding to the next control cycle. As it has been confirmed by Varian technical support, this effect causes that measured positions appear in dynalogs one cycle out of phase with respect to the planned positions. Around 9000 dynalogs have been analyzed, coming from the three linear accelerators of our center (one Trilogy and two Clinac 21EX) equipped with a Millennium 120 MLC. In order to compare our results to recent publications, leaf positioning errors (RMS and 95th percentile) are calculated with and without delay effect. Dynalogs have been analyzed using a in-house Matlab software. Results: The RMS errors were 0.341, 0.339 and 0.348mm for each Linac; being the average error 0.343 mm. The 95th percentiles of the error were 0.617, 0.607 and 0.625; with an average of 0.617mm. A recent multi-institution study carried out by Kerns et al. found a mean leaf RMS error of 0.32mm and a 95th percentile error value of 0.64mm.Without delay effect, mean leaf RMS errors obtained were 0.040, 0.042 and 0.038mm for each treatment machine; being the average 0.040mm. The 95th percentile error values obtained were 0.057, 0.058 and 0.054 mm, with an average of 0.056mm. Conclusion: Results obtained for the mean leaf RMS error and the mean 95th percentile were consistent with the multi-institution study. Calculated error statistics with delay effect are significantly larger due to the speed proportional and systematic leaf offset. Consequently it is proposed to correct this effect in dynalogs analysis to determine the MLC performance

  17. A new qualitative pattern classification of shear wave elastograghy for solid breast mass evaluation.

    Science.gov (United States)

    Cong, Rui; Li, Jing; Guo, Song

    2017-02-01

    To examine the efficacy of qualitative shear wave elastography (SWE) in the classification and evaluation of solid breast masses, and to compare this method with conventional ultrasonograghy (US), quantitative SWE parameters and qualitative SWE classification proposed before. From April 2015 to March 2016, 314 consecutive females with 325 breast masses who decided to undergo core needle biopsy and/or surgical biopsy were enrolled. Conventional US and SWE were previously performed in all enrolled subjects. Each mass was classified by two different qualitative classifications. One was established in our study, herein named the Qual1. Qual1 could classify the SWE images into five color patterns by the visual evaluations: Color pattern 1 (homogeneous pattern); Color pattern 2 (comparative homogeneous pattern); Color pattern 3 (irregularly heterogeneous pattern); Color pattern 4 (intralesional echo pattern); and Color pattern 5 (the stiff rim sign pattern). The second qualitative classification was named Qual2 here, and included a four-color overlay pattern classification (Tozaki and Fukuma, Acta Radiologica, 2011). The Breast Imaging Reporting and Data System (BI-RADS) assessment and quantitative SWE parameters were recorded. Diagnostic performances of conventional US, SWE parameters, and combinations of US and SWE parameters were compared. With pathological results as the gold standard, of the 325 examined breast masses, 139 (42.77%) samples were malignant and 186 (57.23%) were benign. The Qual1 showed a higher Az value than the Qual2 and quantitative SWE parameters (all Pbreast mass diagnoses. Copyright © 2016. Published by Elsevier B.V.

  18. Fracture network evaluation program (FraNEP): A software for analyzing 2D fracture trace-line maps

    Science.gov (United States)

    Zeeb, Conny; Gomez-Rivas, Enrique; Bons, Paul D.; Virgo, Simon; Blum, Philipp

    2013-10-01

    Fractures, such as joints, faults and veins, strongly influence the transport of fluids through rocks by either enhancing or inhibiting flow. Techniques used for the automatic detection of lineaments from satellite images and aerial photographs, LIDAR technologies and borehole televiewers significantly enhanced data acquisition. The analysis of such data is often performed manually or with different analysis software. Here we present a novel program for the analysis of 2D fracture networks called FraNEP (Fracture Network Evaluation Program). The program was developed using Visual Basic for Applications in Microsoft Excel™ and combines features from different existing software and characterization techniques. The main novelty of FraNEP is the possibility to analyse trace-line maps of fracture networks applying the (1) scanline sampling, (2) window sampling or (3) circular scanline and window method, without the need of switching programs. Additionally, binning problems are avoided by using cumulative distributions, rather than probability density functions. FraNEP is a time-efficient tool for the characterisation of fracture network parameters, such as density, intensity and mean length. Furthermore, fracture strikes can be visualized using rose diagrams and a fitting routine evaluates the distribution of fracture lengths. As an example of its application, we use FraNEP to analyse a case study of lineament data from a satellite image of the Oman Mountains.

  19. Tetrodotoxin and paralytic shellfish poisons in gastropod species from Vietnam analyzed by high-performance liquid chromatography and liquid chromatography–tandem mass spectrometry

    Directory of Open Access Journals (Sweden)

    Hsiao-Chin Jen

    2014-06-01

    Full Text Available Among marine toxins, tetrodotoxin (TTX and paralytic shellfish poisons (PSPs are known as notorious neurotoxins that induce serious food poisoning incidents in the Southeast Asia region. The aim of this study was to investigate whether TTX and PSP toxins are important issues of seafood safety. Paralytic toxicity was observed in mice exposed to 34 specimens from five species of gastropods using a PSP bioassay. Five species of gastropods, Natica vitellus, Natica tumidus, Oliva hirasei, Oliva lignaria, and Oliva annulata, were collected from the coastal seawaters in Nha Trang City, Vietnam, between August 2007 and October 2007. The average lethal potency of gastropod specimens was 90 ± 40 (mean ± standard deviation mouse units (MU for N. vitellus, 64 ± 19 MU for N. tumidus, 42 ± 28 MU for O. hirasei, 51 ± 17 MU for O. lignaria, and 39 ± 18 MU for O. annulata. All toxic extracts from the sample species were clarified using a C18 Sep-Pak solid-phase extraction column and a microcentrifuge filter prior to analysis. High-performance liquid chromatography coupled with fluorescence detection indicated that the toxins of the olive shell (O. hirasei, O. lignaria, and O. annulata were mainly composed of saxitoxin (STX (73–82%, gonyautoxin (GTX 2, 3 (12–22%, and minor levels of TTX (5–6%. The toxins of N. vitellus and N. tumidus were mainly composed of STX (76–81% and GTX 1, 4 (19–24%. Furthermore, liquid chromatography–tandem mass spectrometry analysis was used to verify the identity of the PSPs and TTX. Our evidence shows that these gastropods have novel toxin profiles.

  20. Evaluation of an in-situ x-ray fluorescence analyzer for inorganic pollutants in sediments and water columns

    International Nuclear Information System (INIS)

    Wogman, N.A.

    1979-09-01

    The applicability of an energy dispersive x-ray fluorescence spectrometer for measurement of trace elements in sediments and in water columns from Coast Guard vessels has been investigated. This investigation was conducted in both freshwater and saltwater areas and included Puget Sound, Lake Washington, Lake Union, and the ship canal in the State of Washington. The spectrometer system consisted of a solid cryogen-cooled Si(Li) detector and a 109 Cd excitation source. Sediments and water columns were viewed through a 0.2 mm Be window. This study showed the feasibility of measuring trace elements at concentrations ranging from 20 to about 100 ppM. Measurements of this sensitivity with a 100 mCi 109 Cd source are possible for time intervals as short as 5 minutes. This in-situ measurement capability permits the on-site mapping of pollution and avoids the problem of sediment disturbance which is inherent in the collection of grab samples of the sediment surface. Recommendations for an improved analyzer system included a detector assembly which could be towed, or allow continuous sediment surface analysis thereby recording the average composition of a large area

  1. An evaluation of three-dimensional modeling of compaction cycles by analyzing the densification behavior of binary and ternary mixtures.

    Science.gov (United States)

    Picker, K M; Bikane, F

    2001-08-01

    The aim of the study is to use the 3D modeling technique of compaction cycles for analysis of binary and ternary mixtures. Three materials with very different deformation and densification characteristics [cellulose acetate (CAC), dicalcium phosphate dihydrate (EM) and theophylline monohydrate (TM)] have been tableted at graded maximum relative densities (rhorel, max) on an eccentric tableting machine. Following that, graded binary mixtures from CAC and EM have been compacted. Finally, the same ratios of CAC and EM have been tableted in a ternary mixture with 20 vol% TM. All compaction cycles have been analyzed by using different data analysis methods. Three-dimensional modeling, conventional determination of the slope of the Heckel function, determination of the elastic recovery during decompression, and calculations according to the pressure-time function were the methods of choice. The results show that the 3D model technique is able to gain the information in one step instead of three different approaches, which is an advantage for formulation development. The results show that this model enables one to better distinguish the compaction properties of mixtures and the interaction of the components in the tablet than 2D models. Furthermore, the information by 3D modeling is more precise since in the slope K of the Heckel-plot (in die) elasticity is included, and in the parameters of the pressure-time function beta and gamma plastic deformation due to pressure is included. The influence of time and pressure on the displacement can now be differentiated.

  2. Evaluation of fine ceramics raw powders with particle size analyzers having different measuring principle and its problem

    International Nuclear Information System (INIS)

    Hayakawa, Osamu; Nakahira, Kenji; Tsubaki, Junichiro.

    1995-01-01

    Many kinds of analyzers based on various principles have been developed for measuring particle size distribution of fine ceramics powders. But the reproducibility of the results, interchangeability of the models, reliability of the ends of the measured distribution have not been investigated for each principle. In this paper, these important points for particle size analysis were clarified by measuring raw material powders of fine ceramics. (1) in the case of laser diffraction and scattering method, the reproducibility in the same model is good, however, interchangeability of the different models is not so good, especially at the ends of the distribution. Submicron powders having high refractive index show such a tendency remarkably. (2) the photo sedimentation method has some problems to be conquered, especially in measuring submicron powders having high refractive index or flaky shape particles. The reproducibility of X-ray sedimentation method is much better than that of photo sedimentation. (3) the light obscuration and electrical sensing zone methods, show good reproducibility, however, sometime bad interchangeability is affected by calibration and so on. (author)

  3. Evaluation of bromide mass discharge in a sandy aquifer at Vandenberg AFB, CA

    Science.gov (United States)

    Mackay, D. M.; Rasa, E.; Einarson, M.; Kaiser, P.; Chakraborty, I.; Scow, K. M.

    2009-12-01

    Side-by-side experiments were conducted by UC Davis research team at a former fuel station at Vandenberg Air Force Base (AFB) to evaluate the rate of transformation of methyl tert-butyl ether (MTBE) to tert-butyl alcohol (TBA) impacted by ethanol and to investigate evidence of TBA degradation under sulfate reducing conditions. On one side we injected groundwater amended with ethanol and MTBE. In the other lane we injected groundwater amended with TBA. On both sides, injected ground water was spiked with bromide tracer to provide estimates of groundwater flow direction variations, flow velocity, dispersion, and mobile mass loss resulting from diffusive sequestration into aquitards. 162 monitoring wells were aligned into seven transects located downgradient of the injection wells. The mass discharge approach was used to evaluate the natural attenuation of the injected constituents. In this talk we will focus on calculations of mass discharge of the bromide tracer at each of the seven monitoring well transects. The amount of bromide mass discharged through each transect was calculated for any sampling time using field measurements of break through curves. Cumulative mass discharges were estimated and, by iteration based on mass balance, the flow properties of the aquifer were estimated. The calibration process resulted in subtle but quantitatively important changes in our assumptions regarding key physical properties of the aquifer (thickness, porosity) which could be only approximately estimated by standard methods (coring, CPT, etc.). On the basis of this calibration, a more robust approach was devised for evaluating the source and fate of TBA in the aquifer.

  4. Sucrose and color profiles in sugarcane (Saccharum sp.) juice analyzed by UFLC-ELSD and Synapt High-Definition Mass Spectrometry during radiation treatment

    International Nuclear Information System (INIS)

    Lima, Roberta B.; Lima de Aguiar, Claudio; Galaverna, Renan; Baptista, Antonio S.; Eberlin, Marcos N.; Arthur, Valter

    2016-01-01

    This work evaluated the effect of electron beam irradiation (E-beam) on sugarcane juice and compared the results with preliminary tests performed on sugarcane juice treated with gamma irradiation. The samples were irradiated at 5, 10 and 20 kGy doses and results were compared wile control samples without irradiation. The results showed a significant increase (p≤0.05) of phenolic compounds in both treatments. We also observed increased contents of reducing sugars (glucose and fructose) for the samples irradiated with gamma rays and E-beam measured by the DNS methods. However, there was no significant difference of sugars content measured by chromatographic analyses performed in the sugarcane juice treated with E-beam. Therefore reducing sugars content could be overestimated by the DNS method because salts in sugarcane juice. The treatments were able to reduce sugarcane juice ICUMSA color intensity in both treatments with irradiation. E-beam reduced sugarcane juice color by roughly 49% compared the control, while gamma irradiation reduced it by 30%. - Highlights: • E-beam and γ-radiation were evaluated on color reduction of sugarcane juice. • Any severe degradation of sucrose content was perceived by E-beam or γ-radiation. • Little degradation of sucrose was associated to the increase on radiation doses. • Average color reduction was found to be 49% with E-beam and 30% with γ-radiation. • Synapt HDMS was able to confirm the presence of sucrose, glucose and fructose.

  5. Performance evaluation of a particle-enhanced turbidimetric cystatin C assay on the Abbott ci8200 analyzer.

    Science.gov (United States)

    Flodin, Mats; Larsson, Anders

    2009-06-01

    Glomerular filtration rate (GFR) is widely accepted as the best overall measure of kidney function. Cystatin C is a novel endogenous GFR marker that has been shown to be superior to creatinine for estimation of GFR in several studies. There is a need for cystatin C assays adapted to routine chemistry instrument to minimize turnaround times and allowing 24 h/day availability. We have evaluated a new cystatin C assay developed for Architect cSystem (Abbott Laboratories, Abbott Park, IL, USA). The cystatin C assay showed good agreement with the corresponding assay from Dade Behring (Deerfield, IL, USA). The assay has a very low total imprecision and a good linearity. The new cystatin C assay is an interesting alternative to current cystatin C assays. On an Architect cSystem the assay can be performed with the same turnaround times and availability as creatinine.

  6. Evaluation of a mass-balance approach to determine consumptive water use in northeastern Illinois

    Science.gov (United States)

    Mills, Patrick C.; Duncker, James J.; Over, Thomas M.; Marian Domanski,; ,; Engel, Frank

    2014-01-01

    A principal component of evaluating and managing water use is consumptive use. This is the portion of water withdrawn for a particular use, such as residential, which is evaporated, transpired, incorporated into products or crops, consumed by humans or livestock, or otherwise removed from the immediate water environment. The amount of consumptive use may be estimated by a water (mass)-balance approach; however, because of the difficulty of obtaining necessary data, its application typically is restricted to the facility scale. The general governing mass-balance equation is: Consumptive use = Water supplied - Return flows.

  7. Evaluation of Long-term Performance of Enhanced Anaerobic Source Zone Bioremediation using mass flux

    Science.gov (United States)

    Haluska, A.; Cho, J.; Hatzinger, P.; Annable, M. D.

    2017-12-01

    Chlorinated ethene DNAPL source zones in groundwater act as potential long term sources of contamination as they dissolve yielding concentrations well above MCLs, posing an on-going public health risk. Enhanced bioremediation has been applied to treat many source zones with significant promise, but long-term sustainability of this technology has not been thoroughly assessed. This study evaluated the long-term effectiveness of enhanced anaerobic source zone bioremediation at chloroethene contaminated sites to determine if the treatment prevented contaminant rebound and removed NAPL from the source zone. Long-term performance was evaluated based on achieving MCL-based contaminant mass fluxes in parent compound concentrations during different monitoring periods. Groundwater concertation versus time data was compiled for 6-sites and post-remedial contaminant mass flux data was then measured using passive flux meters at wells both within and down-gradient of the source zone. Post-remedial mass flux data was then combined with pre-remedial water quality data to estimate pre-remedial mass flux. This information was used to characterize a DNAPL dissolution source strength function, such as the Power Law Model and the Equilibrium Stream tube model. The six-sites characterized for this study were (1) Former Charleston Air Force Base, Charleston, SC; (2) Dover Air Force Base, Dover, DE; (3) Treasure Island Naval Station, San Francisco, CA; (4) Former Raritan Arsenal, Edison, NJ; (5) Naval Air Station, Jacksonville, FL; and, (6) Former Naval Air Station, Alameda, CA. Contaminant mass fluxes decreased for all the sites by the end of the post-treatment monitoring period and rebound was limited within the source zone. Post remedial source strength function estimates suggest that decreases in contaminant mass flux will continue to occur at these sites, but a mass flux based on MCL levels may never be exceeded. Thus, site clean-up goals should be evaluated as order

  8. Uncertainty in decision models analyzing cost-effectiveness : The joint distribution of incremental costs and effectiveness evaluated with a nonparametric bootstrap method

    NARCIS (Netherlands)

    Hunink, Maria; Bult, J.R.; De Vries, J; Weinstein, MC

    1998-01-01

    Purpose. To illustrate the use of a nonparametric bootstrap method in the evaluation of uncertainty in decision models analyzing cost-effectiveness. Methods. The authors reevaluated a previously published cost-effectiveness analysis that used a Markov model comparing initial percutaneous

  9. Postmortem Tissue Distribution of Acetyl Fentanyl, Fentanyl and their Respective Nor-Metabolites Analyzed by Ultrahigh Performance Liquid Chromatography with Tandem Mass Spectrometry

    Science.gov (United States)

    Poklis, Justin; Poklis, Alphonse; Wolf, Carl; Mainland, Mary; Hair, Laura; Devers, Kelly; Chrostowski, Leszek; Arbefeville, Elise; Merves, Michele; Pearson, Julia

    2015-01-01

    In the last two years, an epidemic of fatal narcotic overdose cases has occurred in the Tampa area of Florida. Fourteen of these deaths involved fentanyl and/or the new designer drug, acetyl fentanyl. Victim demographics, case histories, toxicology findings and causes and manners of death, as well as, disposition of fentanyl derivatives and their nor-metabolites in postmortem heart blood, peripheral blood, bile, brain, liver, urine and vitreous humor are presented. In the cases involving only acetyl fentanyl (without fentanyl, n=4), the average peripheral blood acetyl fentanyl concentration was 0.467 mg/L (range 0.31 to .60 mg/L) and average acetyl norfentanyl concentration was 0.053 mg/L (range 0.002 to 0.086 mg/L). In the cases involving fentanyl (without acetyl fentanyl, n=7), the average peripheral blood fentanyl concentration was 0.012 mg/L (range 0.004 to 0.027 mg/L) and average norfentanyl blood concentration was 0.001 mg/L (range 0.0002 to 0.003 mg/L). In the cases involving both acetyl fentanyl and fentanyl (n=3), the average peripheral blood acetyl fentanyl concentration was 0.008 mg/L (range 0.006 to 0.012 mg/L), the average peripheral blood acetyl norfentanyl concentration was 0.001 mg/L (range 0.001 to 0.002 mg/L), the average peripheral blood fentanyl concentration was 0.018 mg/L (range 0.015 to 0.021 mg/L) and the average peripheral blood norfentanyl concentration was 0.002 mg/L (range 0.001 mg/L to 0.003 mg/L). Based on the toxicology results, it is evident that when fentanyl and/or acetyl fentanyl were present, they contributed to the cause of death. A novel ultrahigh performance liquid chromatography (UPLC) tandem mass spectrometry (MS/MS) method to identify and quantify acetyl fentanyl, acetyl norfentanyl, fentanyl and norfentanyl in postmortem fluids and tissues is also presented. PMID:26583960

  10. Direct analysis and identification of pathogenic Lichtheimia species by matrix-assisted laser desorption ionization-time of flight analyzer-mediated mass spectrometry.

    Science.gov (United States)

    Schrödl, Wieland; Heydel, Tilo; Schwartze, Volker U; Hoffmann, Kerstin; Grosse-Herrenthey, Anke; Walther, Grit; Alastruey-Izquierdo, Ana; Rodriguez-Tudela, Juan Luis; Olias, Philipp; Jacobsen, Ilse D; de Hoog, G Sybren; Voigt, Kerstin

    2012-02-01

    Zygomycetes of the order Mucorales can cause life-threatening infections in humans. These mucormycoses are emerging and associated with a rapid tissue destruction and high mortality. The resistance of Mucorales to antimycotic substances varies between and within clinically important genera such as Mucor, Rhizopus, and Lichtheimia. Thus, an accurate diagnosis before onset of antimycotic therapy is recommended. Matrix-assisted laser desorption ionization (MALDI)-time of flight (TOF) mass spectrometry (MS) is a potentially powerful tool to rapidly identify infectious agents on the species level. We investigated the potential of MALDI-TOF MS to differentiate Lichtheimia species, one of the most important agents of mucormycoses. Using the Bruker Daltonics FlexAnalysis (version 3.0) software package, a spectral database library with m/z ratios of 2,000 to 20,000 Da was created for 19 type and reference strains of clinically relevant Zygomycetes of the order Mucorales (12 species in 7 genera). The database was tested for accuracy by use of 34 clinical and environmental isolates of Lichtheimia comprising a total of five species. Our data demonstrate that MALDI-TOF MS can be used to clearly discriminate Lichtheimia species from other pathogenic species of the Mucorales. Furthermore, the method is suitable to discriminate species within the genus. The reliability and robustness of the MALDI-TOF-based identification are evidenced by high score values (above 2.3) for the designation to a certain species and by moderate score values (below 2.0) for the discrimination between clinically relevant (Lichtheimia corymbifera, L. ramosa, and L. ornata) and irrelevant (L. hyalospora and L. sphaerocystis) species. In total, all 34 strains were unequivocally identified by MALDI-TOF MS with score values of >1.8 down to the generic level, 32 out of 34 of the Lichtheimia isolates (except CNM-CM 5399 and FSU 10566) were identified accurately with score values of >2 (probable species

  11. Direct Analysis and Identification of Pathogenic Lichtheimia Species by Matrix-Assisted Laser Desorption Ionization–Time of Flight Analyzer-Mediated Mass Spectrometry

    Science.gov (United States)

    Schrödl, Wieland; Heydel, Tilo; Schwartze, Volker U.; Hoffmann, Kerstin; Große-Herrenthey, Anke; Walther, Grit; Alastruey-Izquierdo, Ana; Rodriguez-Tudela, Juan Luis; Olias, Philipp; Jacobsen, Ilse D.; de Hoog, G. Sybren

    2012-01-01

    Zygomycetes of the order Mucorales can cause life-threatening infections in humans. These mucormycoses are emerging and associated with a rapid tissue destruction and high mortality. The resistance of Mucorales to antimycotic substances varies between and within clinically important genera such as Mucor, Rhizopus, and Lichtheimia. Thus, an accurate diagnosis before onset of antimycotic therapy is recommended. Matrix-assisted laser desorption ionization (MALDI)–time of flight (TOF) mass spectrometry (MS) is a potentially powerful tool to rapidly identify infectious agents on the species level. We investigated the potential of MALDI-TOF MS to differentiate Lichtheimia species, one of the most important agents of mucormycoses. Using the Bruker Daltonics FlexAnalysis (version 3.0) software package, a spectral database library with m/z ratios of 2,000 to 20,000 Da was created for 19 type and reference strains of clinically relevant Zygomycetes of the order Mucorales (12 species in 7 genera). The database was tested for accuracy by use of 34 clinical and environmental isolates of Lichtheimia comprising a total of five species. Our data demonstrate that MALDI-TOF MS can be used to clearly discriminate Lichtheimia species from other pathogenic species of the Mucorales. Furthermore, the method is suitable to discriminate species within the genus. The reliability and robustness of the MALDI-TOF-based identification are evidenced by high score values (above 2.3) for the designation to a certain species and by moderate score values (below 2.0) for the discrimination between clinically relevant (Lichtheimia corymbifera, L. ramosa, and L. ornata) and irrelevant (L. hyalospora and L. sphaerocystis) species. In total, all 34 strains were unequivocally identified by MALDI-TOF MS with score values of >1.8 down to the generic level, 32 out of 34 of the Lichtheimia isolates (except CNM-CM 5399 and FSU 10566) were identified accurately with score values of >2 (probable species

  12. Evaluation of a lower-powered analyzer and sampling system for eddy-covariance measurements of nitrous oxide fluxes

    Science.gov (United States)

    Brown, Shannon E.; Sargent, Steve; Wagner-Riddle, Claudia

    2018-03-01

    Nitrous oxide (N2O) fluxes measured using the eddy-covariance method capture the spatial and temporal heterogeneity of N2O emissions. Most closed-path trace-gas analyzers for eddy-covariance measurements have large-volume, multi-pass absorption cells that necessitate high flow rates for ample frequency response, thus requiring high-power sample pumps. Other sampling system components, including rain caps, filters, dryers, and tubing, can also degrade system frequency response. This field trial tested the performance of a closed-path eddy-covariance system for N2O flux measurements with improvements to use less power while maintaining the frequency response. The new system consists of a thermoelectrically cooled tunable diode laser absorption spectrometer configured to measure both N2O and carbon dioxide (CO2). The system features a relatively small, single-pass sample cell (200 mL) that provides good frequency response with a lower-powered pump ( ˜ 250 W). A new filterless intake removes particulates from the sample air stream with no additional mixing volume that could degrade frequency response. A single-tube dryer removes water vapour from the sample to avoid the need for density or spectroscopic corrections, while maintaining frequency response. This eddy-covariance system was collocated with a previous tunable diode laser absorption spectrometer model to compare N2O and CO2 flux measurements for two full growing seasons (May 2015 to October 2016) in a fertilized cornfield in Southern Ontario, Canada. Both spectrometers were placed outdoors at the base of the sampling tower, demonstrating ruggedness for a range of environmental conditions (minimum to maximum daily temperature range: -26.1 to 31.6 °C). The new system rarely required maintenance. An in situ frequency-response test demonstrated that the cutoff frequency of the new system was better than the old system (3.5 Hz compared to 2.30 Hz) and similar to that of a closed-path CO2 eddy-covariance system (4

  13. Evaluation of the schemes of protections of Sistema Nacional Interconectado of year 2014 by analyzing the transient stability

    International Nuclear Information System (INIS)

    Rojas Rojas, Luis Felipe

    2012-01-01

    The elaboration of a study of transient stability is seen as part of the planning process associated with the Plan de Expansion de la Transmision. Studies have historically contemplated the calculation of critics times of release of failures without allowing to obtain conclusive information about the performance of protection systems. An evaluation of the protection schemes of substations is determined make of the Sistema Nacional Interconectado of year 2014. Analysis of transient stability was used to verify compliance with the ''Criterios de Seguridad para la Planificacion, Diseno y Operacion del Sistema Electrico Nacional'' and ''Criterios de Calidad, Seguridad y Desempeno'' of the Reglamento del Mercado Electrico Regional in order to determine the necessary improvements. A methodology is proposed for simulating the behavior of protection systems using the software PSS/E, which has replaced the methodology based on the calculation of critical times. The presence of 42 substations were determined in which the release of failures for remote backup has caused unstable conditions of the system. 174 improvements have identified as necessary among which are: the implementation of distance relays in autotransformers, differential protections in reactors, differentials of lines and overcurrents of definite time in lines, duplication of differentials in bars, the replacement of pole breakers for monopolar and duplication of breakers of link bars. The current criteria have been recommended to supplement with probabilistic criteria to avoid incurring unnecessary investments. (author) [es

  14. Reproducibility and diagnostic performance of shear wave elastography in evaluating breast solid mass.

    Science.gov (United States)

    Hong, Sun; Woo, Ok Hee; Shin, Hye Seon; Hwang, Soon-Young; Cho, Kyu Ran; Seo, Bo Kyoung

    Shear wave elastography (SWE) was performed independently by two radiologists in 264 solid breast masses. The images were reviewed for color overlay pattern (COP) classification by the two radiologists, double blinded to any information. The interobserver agreement of the COP was almost perfect (κ=0.908) and high in E max (ICC=0.89). The AUC value of the COP (0.954) was significantly higher than that of E max (0.915) (p=0.002) but not significantly different from that of E max combined with COP (0.957) (p=0.098). The SWE color overlay pattern and E max of breast masses were highly reproducible. The COP had better diagnostic ability than E max , suggesting that COP may be a more reliable parameter for solid breast mass evaluation. Copyright © 2017 Elsevier Inc. All rights reserved.

  15. Evaluation of a lower-powered analyzer and sampling system for eddy-covariance measurements of nitrous oxide fluxes

    Directory of Open Access Journals (Sweden)

    S. E. Brown

    2018-03-01

    Full Text Available Nitrous oxide (N2O fluxes measured using the eddy-covariance method capture the spatial and temporal heterogeneity of N2O emissions. Most closed-path trace-gas analyzers for eddy-covariance measurements have large-volume, multi-pass absorption cells that necessitate high flow rates for ample frequency response, thus requiring high-power sample pumps. Other sampling system components, including rain caps, filters, dryers, and tubing, can also degrade system frequency response. This field trial tested the performance of a closed-path eddy-covariance system for N2O flux measurements with improvements to use less power while maintaining the frequency response. The new system consists of a thermoelectrically cooled tunable diode laser absorption spectrometer configured to measure both N2O and carbon dioxide (CO2. The system features a relatively small, single-pass sample cell (200 mL that provides good frequency response with a lower-powered pump ( ∼  250 W. A new filterless intake removes particulates from the sample air stream with no additional mixing volume that could degrade frequency response. A single-tube dryer removes water vapour from the sample to avoid the need for density or spectroscopic corrections, while maintaining frequency response. This eddy-covariance system was collocated with a previous tunable diode laser absorption spectrometer model to compare N2O and CO2 flux measurements for two full growing seasons (May 2015 to October 2016 in a fertilized cornfield in Southern Ontario, Canada. Both spectrometers were placed outdoors at the base of the sampling tower, demonstrating ruggedness for a range of environmental conditions (minimum to maximum daily temperature range: −26.1 to 31.6 °C. The new system rarely required maintenance. An in situ frequency-response test demonstrated that the cutoff frequency of the new system was better than the old system (3.5 Hz compared to 2.30 Hz and similar to that of a closed

  16. Sucrose and color profiles in sugarcane (Saccharum sp.) juice analyzed by UFLC-ELSD and Synapt High-Definition Mass Spectrometry during radiation treatment

    Science.gov (United States)

    Lima, Roberta B.; de Aguiar, Claudio Lima; Galaverna, Renan; Baptista, Antonio S.; Eberlin, Marcos N.; Arthur, Valter

    2016-04-01

    This work evaluated the effect of electron beam irradiation (E-beam) on sugarcane juice and compared the results with preliminary tests performed on sugarcane juice treated with gamma irradiation. The samples were irradiated at 5, 10 and 20 kGy doses and results were compared wile control samples without irradiation. The results showed a significant increase (p≤0.05) of phenolic compounds in both treatments. We also observed increased contents of reducing sugars (glucose and fructose) for the samples irradiated with gamma rays and E-beam measured by the DNS methods. However, there was no significant difference of sugars content measured by chromatographic analyses performed in the sugarcane juice treated with E-beam. Therefore reducing sugars content could be overestimated by the DNS method because salts in sugarcane juice. The treatments were able to reduce sugarcane juice ICUMSA color intensity in both treatments with irradiation. E-beam reduced sugarcane juice color by roughly 49% compared the control, while gamma irradiation reduced it by 30%.

  17. Orbitrap mass analyser for in situ characterisation of planetary environments: Performance evaluation of a laboratory prototype

    Science.gov (United States)

    Briois, Christelle; Thissen, Roland; Thirkell, Laurent; Aradj, Kenzi; Bouabdellah, Abdel; Boukrara, Amirouche; Carrasco, Nathalie; Chalumeau, Gilles; Chapelon, Olivier; Colin, Fabrice; Coll, Patrice; Cottin, Hervé; Engrand, Cécile; Grand, Noel; Lebreton, Jean-Pierre; Orthous-Daunay, François-Régis; Pennanech, Cyril; Szopa, Cyril; Vuitton, Véronique; Zapf, Pascal; Makarov, Alexander

    2016-10-01

    For decades of space exploration, mass spectrometry has proven to be a reliable instrumentation for the characterisation of the nature and energy of ionic and neutral, atomic and molecular species in the interplanetary medium and upper planetary atmospheres. It has been used as well to analyse the chemical composition of planetary and small bodies environments. The chemical complexity of these environments calls for the need to develop a new generation of mass spectrometers with significantly increased mass resolving power. The recently developed OrbitrapTM mass analyser at ultra-high resolution shows promising adaptability to space instrumentation, offering improved performances for in situ measurements. In this article, we report on our project named ;Cosmorbitrap; aiming at demonstrating the adaptability of the Orbitrap technology for in situ space exploration. We present the prototype that was developed in the laboratory for demonstration of both technical feasibility and analytical capabilities. A set of samples containing elements with masses ranging from 9 to 208 u has been used to evaluate the performance of the analyser, in terms of mass resolving power (reaching 474,000 at m/z 9) and ability to discriminate between isobaric interferences, accuracy of mass measurement (below 15 ppm) and determination of relative isotopic abundances (below 5%) of various samples. We observe a good agreement between the results obtained with the prototype and those of a commercial instrument. As the background pressure is a key parameter for in situ exploration of atmosphere planetary bodies, we study the effect of background gas on the performance of the Cosmorbitrap prototype, showing an upper limit for N2 in our set-up at 10-8 mbar. The results demonstrate the strong potential to adapt this technology to space exploration.

  18. Evaluation of high-resolution mass spectrometry for urine toxicology screening in a pain management setting.

    Science.gov (United States)

    Crews, Bridgit O; Pesce, Amadeo J; West, Robert; Nguyen, Hugh; Fitzgerald, Robert L

    2012-01-01

    To evaluate liquid chromatography-high-resolution mass spectrometry (LC-HR-MS) for urine toxicology screening, 29 analytes were quantitated in 152 urine specimens from patients with chronic pain using two unique mass spectrometry platforms. De-identified specimens were quantitated in April of 2011 by liquid chromatography-triple quadrupole mass spectrometry (LC-MS-MS) and by full-scan LC-HR-MS at Millennium Laboratories. Considering LC-MS-MS as the reference method, false positive results were identified in 19 specimens measured by LC-HR-MS. Application of relative retention times using deuterium labeled internal standards improved the rate of false positive detection to only five specimens, with four occurring for the same analyte. Ultra-high-resolution mass spectrometry (R = 100,000 at m/z 200) showed no improvement over high-resolution mass spectrometry (R = 10,000 at m/z 200) in the number of false positives detected. Quantitative results measured by LC-MS-MS and LC-HR-MS showed good agreement over four orders of dynamic range. This study demonstrates that LC-HR-MS is a suitable platform for toxicology screening for a pain management population and that quantitative accuracy and sensitivity are comparable to that achieved with LC-MS-MS. The specificity of LC-HR-MS is improved by the addition of deuterium labeled internal standards and the implementation of relative retention time matching.

  19. The Ame2012 atomic mass evaluation. Pt. 2. Tables, graphs and references

    International Nuclear Information System (INIS)

    Wang, M.; Audi, G.; Wapstra, A.H.; Kondev, F.G.; MacCormick, M.; Xu, X.; Pfeiffer, B.

    2012-01-01

    This paper is the second part of the new evaluation of atomic masses, Ame2012. From the results of a least-squares calculation, described in Part I, for all accepted experimental data, we derive here tables and graphs to replace those of Ame2003. The first table lists atomic masses. It is followed by a table of the influences of data on primary nuclides, a table of separation energies and reaction energies, and finally, a series of graphs of separation and decay energies. The last section in this paper lists all references to the input data used in Part I of this Ame2012 and also to the data included in the Nubase2012 evaluation (first paper in this issue). (authors)

  20. Intrahepatic and hilar mass-forming cholangiocarcinoma: Qualitative and quantitative evaluation with diffusion-weighted MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Fattach, Hassan El, E-mail: hassangreenmed@gmail.com [Department of Abdominal Imaging, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, 2 rue Ambroise Paré, 75010 Paris (France); Dohan, Anthony, E-mail: anthony.dohan@lrb.aphp.fr [Department of Abdominal Imaging, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, 2 rue Ambroise Paré, 75010 Paris (France); Université Paris-Diderot, Sorbonne Paris Cité, 10 Avenue de Verdun, 75010 Paris (France); UMR INSERM 965-Paris 7 “Angiogenèse et recherche translationnelle”, 2 rue Amboise Paré, 75010 Paris (France); Guerrache, Youcef, E-mail: docyoucef05@yahoo.fr [Department of Abdominal Imaging, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, 2 rue Ambroise Paré, 75010 Paris (France); Dautry, Raphael, E-mail: raphael.dautry@lrb.aphp.fr [Department of Abdominal Imaging, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, 2 rue Ambroise Paré, 75010 Paris (France); Université Paris-Diderot, Sorbonne Paris Cité, 10 Avenue de Verdun, 75010 Paris (France); and others

    2015-08-15

    Highlights: • DW-MR imaging helps depicts all intrahepatic or hilar mass-forming cholangiocarcinomas. • DW-MRI provides best conspicuity of intrahepatic or hilar mass-forming cholangiocarcinomas than the other MRI sequences (P < 0.001). • The use of normalized ADC using the liver as reference organ results in the most restricted distribution of ADC values of intrahepatic or hilar mass-forming cholangiocarcinomas (variation coefficient = 16.6%). - Abstract: Objective: To qualitatively and quantitatively analyze the presentation of intrahepatic and hilar mass-forming cholangiocarcinoma with diffusion-weighted magnetic resonance imaging (DW-MRI). Materials and methods: Twenty-eight patients with histopathologically proven mass-forming cholangiocarcinoma (hilar, n = 17; intrahepatic, n = 11) underwent hepatic DW-MRI at 1.5-T using free-breathing acquisition and three b-values (0,400,800 s/mm{sup 2}). Cholangiocarcinomas were evaluated qualitatively using visual analysis of DW-MR images and quantitatively with conventional ADC and normalized ADC measurements using liver and spleen as reference organs. Results: All cholangiocarcinomas (28/28; 100%) were visible on DW-MR images. DW-MRI yielded best conspicuity of cholangiocarcinomas than the other MRI sequences (P < 0.001). Seven cholangiocarcinomas (7/11; 64%) showed hypointense central area on DW-MR images. Conventional ADC value of cholangiocarcinomas (1.042 × 10{sup −3} mm{sup 2}/s ± 0.221 × 10{sup −3} mm{sup 2}/s; range: 0.616 × 10{sup −3} mm{sup 2}/s to 2.050 × 10{sup −3} mm{sup 2}/s) was significantly lower than that of apparently normal hepatic parenchyma (1.362 × 10{sup −3} mm{sup 2}/s ± 0.187 × 10{sup −3} mm{sup 2}/s) (P < 0.0001), although substantial overlap was found. No significant differences in ADC and normalized ADC values were found between intrahepatic and hilar cholangiocarcinomas. The use of normalized ADC using the liver as reference organ resulted in the most restricted

  1. Intrahepatic and hilar mass-forming cholangiocarcinoma: Qualitative and quantitative evaluation with diffusion-weighted MR imaging

    International Nuclear Information System (INIS)

    Fattach, Hassan El; Dohan, Anthony; Guerrache, Youcef; Dautry, Raphael

    2015-01-01

    Highlights: • DW-MR imaging helps depicts all intrahepatic or hilar mass-forming cholangiocarcinomas. • DW-MRI provides best conspicuity of intrahepatic or hilar mass-forming cholangiocarcinomas than the other MRI sequences (P < 0.001). • The use of normalized ADC using the liver as reference organ results in the most restricted distribution of ADC values of intrahepatic or hilar mass-forming cholangiocarcinomas (variation coefficient = 16.6%). - Abstract: Objective: To qualitatively and quantitatively analyze the presentation of intrahepatic and hilar mass-forming cholangiocarcinoma with diffusion-weighted magnetic resonance imaging (DW-MRI). Materials and methods: Twenty-eight patients with histopathologically proven mass-forming cholangiocarcinoma (hilar, n = 17; intrahepatic, n = 11) underwent hepatic DW-MRI at 1.5-T using free-breathing acquisition and three b-values (0,400,800 s/mm 2 ). Cholangiocarcinomas were evaluated qualitatively using visual analysis of DW-MR images and quantitatively with conventional ADC and normalized ADC measurements using liver and spleen as reference organs. Results: All cholangiocarcinomas (28/28; 100%) were visible on DW-MR images. DW-MRI yielded best conspicuity of cholangiocarcinomas than the other MRI sequences (P < 0.001). Seven cholangiocarcinomas (7/11; 64%) showed hypointense central area on DW-MR images. Conventional ADC value of cholangiocarcinomas (1.042 × 10 −3 mm 2 /s ± 0.221 × 10 −3 mm 2 /s; range: 0.616 × 10 −3 mm 2 /s to 2.050 × 10 −3 mm 2 /s) was significantly lower than that of apparently normal hepatic parenchyma (1.362 × 10 −3 mm 2 /s ± 0.187 × 10 −3 mm 2 /s) (P < 0.0001), although substantial overlap was found. No significant differences in ADC and normalized ADC values were found between intrahepatic and hilar cholangiocarcinomas. The use of normalized ADC using the liver as reference organ resulted in the most restricted distribution of ADC values of cholangiocarcinomas (variation

  2. Evaluation of the U-Pu residual mass from spent fuel assemblies with passive and active neutronic methods

    International Nuclear Information System (INIS)

    Bignan, G.; Martin-Deidier, L.

    1991-01-01

    The interpretation of passive and active neutronic measurements to evaluate the U-Pu residual mass in spent fuel assemblies is presented as follows: passive neutron measurements are well correlated to the plutonium mass, active neutron measurements give information linked to the fissile mass content of the assembly ( 235 U + 239 Pu + 241 Pu) and, using the passive neutron measurement, lead to the 235 U mass content of the assemblies

  3. Space radiation evaluation of 16Mbit DRAMs for mass memory applications

    International Nuclear Information System (INIS)

    Calvel, P.; Lamothe, P.; Barillot, C.; Ecoffet, R.; Duzellier, S.; Stassinopoulos, E.G.

    1994-01-01

    In the frame of Mass Memory Applications for space missions, 16 Mbit DRAM from IBM and TEXAS INSTRUMENTS have been evaluated to space radiation, by the CECIL heavy ions testing coordination group. This paper presents heavy ions, protons and total dose data results for 16 Mbit DRAMs from IBM and TEXAS INSTRUMENTS, including a 'built-in ECC' DRAM. Single Event Phenomena rate are calculated for low earth orbits

  4. A model for evaluating beef cattle rations considering effects of ruminal fiber mass

    OpenAIRE

    Henrique,Douglas Sampaio; Lana,Rogério de Paula; Vieira,Ricardo Augusto Mendonça; Fontes,Carlos Augusto de Alencar; Botelho,Mosar Faria

    2011-01-01

    A mathematical model based on Cornell Net Carbohydrate and Protein System (CNCPS) was developed and adapted in order to evaluate beef cattle rations at tropical climate conditions. The presented system differs from CNCPS in the modeling of insoluble particles' digestion and passage kinetics, which enabled the estimation of fiber mass in rumen and its effects on animal performance. The equations used to estimate metabolizable protein and net energy requirements for gain, net energy requirement...

  5. Statistical program for the data evaluation of a thermal ionization mass spectrometer

    Energy Technology Data Exchange (ETDEWEB)

    van Raaphorst, J. G.

    1978-12-15

    A computer program has been written to statistically analyze mass spectrometer measurements. The program tests whether the difference between signal and background intensities is statistically significant, corrects for signal drift in the measured values, and calculates ratios against the main isotope from the corrected intensities. Repeated ratio value measurements are screened for outliers using the Dixon statistical test. Means of ratios and the coefficient of variation are calculated and reported. The computer program is written in Basic and is available for anyone who is interested.

  6. Evaluating Greenland glacial isostatic adjustment corrections using GRACE, altimetry and surface mass balance data

    International Nuclear Information System (INIS)

    Sutterley, Tyler C; Velicogna, Isabella; Csatho, Beata; Rezvan-Behbahani, Soroush; Babonis, Greg; Van den Broeke, Michiel

    2014-01-01

    Glacial isostatic adjustment (GIA) represents a source of uncertainty for ice sheet mass balance estimates from the Gravity Recovery and Climate Experiment (GRACE) time-variable gravity measurements. We evaluate Greenland GIA corrections from Simpson et al (2009 Quat. Sci. Rev. 28 1631–57), A et al (2013 Geophys. J. Int. 192 557–72) and Wu et al (2010 Nature Geosci. 3 642–6) by comparing the spatial patterns of GRACE-derived ice mass trends calculated using the three corrections with volume changes from ICESat (Ice, Cloud, and land Elevation Satellite) and OIB (Operation IceBridge) altimetry missions, and surface mass balance products from the Regional Atmospheric Climate Model (RACMO). During the period September 2003–August 2011, GRACE ice mass changes obtained using the Simpson et al (2009 Quat. Sci. Rev. 28 1631–57) and A et al (2013 Geophys. J. Int. 192 557–72) GIA corrections yield similar spatial patterns and amplitudes, and are consistent with altimetry observations and surface mass balance data. The two GRACE estimates agree within 2% on average over the entire ice sheet, and better than 15% in four subdivisions of Greenland. The third GRACE estimate corrected using the (Wu et al 2010 Nature Geosci. 3 642–6)) GIA shows similar spatial patterns, but produces an average ice mass loss for the entire ice sheet that is 64 − 67 Gt yr −1 smaller. In the Northeast the recovered ice mass change is 46–49 Gt yr −1 (245–270%) more positive than that deduced from the other two corrections. By comparing the spatial and temporal variability of the GRACE estimates with trends of volume changes from altimetry and surface mass balance from RACMO, we show that the Wu et al (2010 Nature Geosci. 3 642–6) correction leads to a large mass increase in the Northeast that is inconsistent with independent observations. (paper)

  7. The evaluation of properties of coal mass from the viewpoint of environment

    Energy Technology Data Exchange (ETDEWEB)

    Foniok, R.; Lukes, M. [Research Mining Inst., Ostrava-Radvanice (Czechoslovakia)

    1995-12-01

    This paper deals with the evaluation of several various coal kinds from the Czech coalfields from the viewpoint of the development of thermal processes in coal mass due to their tendency towards self- ignition during storing. In such a case that no self-ignition during storing occurs, gaseous products are liberated into air, the quantity and composition of which depend upon fuel type and its temperature as well. From the environmental viewpoint, substances washed from stored coal are of a certain interest, too. In accordance with this fact, the importance of measures against self-heating of stored coal mass and the importance of a detailed observation of coal quality are concluded. The tables, which compare various coal kinds from the viewpoint of their behavior at self-ignition processes, are the integral part of this presented paper. Our greatest attention is paid to both the quantity and composition of gases being liberated in dependence upon the temperature of coal mass, and at its crushing with regard to selected methods and means of milling circuits before and explosion. Oxygen sorption by means of coal mass is also observed, being of a great importance for self-inertization of closed tanks. All the above-mentioned processes are demonstrated in form of graphic plots. Qualitative signs of coal mass are the basic means for its assessment from the viewpoint of emissions at burning/combustion, and the evaluation of explosive properties. A great attention is paid to explosion-proof means being produced in the Czech Republic. These means can be used for protection of milling circuits of power plants and heating plants or for safety systems of combustion chamber by means of insulation to secondary air main. Explosion-proof quci-acting valves, a special type of safety membrane and device for explosion suppression nip in the bud do represent the latest explosion-proof means.

  8. A comprehensive analyzing and evaluating of the results of a wide scope comparison on the environmental level radioactive samples with γ spectrometer

    International Nuclear Information System (INIS)

    Su Qiong; Cheng Jianping; Wang Xuewu; Fan Jiajin; Chen Boxian

    2001-01-01

    A wide scope comparison on the environmental level radioactive samples by γ spectrometers, that has been done in 1998 - 1999, was introduced. Some original data about the comparison are presented. Comprehensive analyzing and evaluating on the comparison results have been done. A new method used for determining comparison reference values, the Model Real Time Weight Average, is adopted. The method is detailed and compared with other models. The practice shows that the Model Real Time Weight Average adopted is feasible and successful

  9. Initial evaluation and referral guidelines for management of pelvic/ovarian masses.

    Science.gov (United States)

    Le, Tien; Giede, Christopher; Salem, Shia; Lefebvre, Guylaine; Rosen, Barry; Bentley, James; Kupets, Rachel; Power, Patti; Renaud, Marie-Claude; Bryson, Peter; Davis, Donald B; Lau, Susie; Lotocki, Robert; Senikas, Vyta; Morin, Lucie; Bly, Stephen; Butt, Kimberly; Cargill, Yvonne M; Denis, Nanette; Gagnon, Robert; Hietala-Coyle, Marja Anne; Lim, Kenneth Ian; Ouellet, Annie; Raciot, Maria-Hélène

    2009-07-01

    To optimize the management of adnexal masses and to assist primary care physicians and gynaecologists determine which patients presenting with an ovarian mass with a significant risk of malignancy should be considered for gynaecologic oncology referral and management. Laparoscopic evaluation, comprehensive surgical staging for early ovarian cancer, or tumour debulking for advanced stage ovarian cancer. To optimize conservative versus operative management of women with possible ovarian malignancy and to optimize the involvement of gynaecologic oncologists in planning and delivery of treatment. Published literature was retrieved through searches of PubMed or MEDLINE, CINAHL, and the Cochrane Library, using appropriate controlled vocabulary and key words. Results were restricted to systematic reviews, randomized control trials/controlled clinical trials, and observational studies. Grey (unpublished) literature was identified by searching the web sites of health technology assessment and health technology assessment-related agencies, clinical practice guideline collections, clinical trial registries, and national and international medical specialty societies. 1. Primary care physicians and gynaecologists should always consider the possibility of an underlying ovarian cancer in patients in any age group who present with an adnexal or ovarian mass. (II-2B) 2. Appropriate workup of a perimenopausal or postmenopausal woman presenting with an adnexal mass should include evaluation of symptoms and signs suggestive of malignancy, such as persistent pelvic/abdominal pain, urinary urgency/frequency, increased abdominal size/bloating, and difficulty eating. In addition, CA125 measurement should be considered. (II-2B) 3. Transvaginal or transabdominal ultrasound examination is recommended as part of the initial workup of a complex adnexal/ovarian mass. (II-2B) 4. Ultrasound reports should be standardized to include size and unilateral/bilateral location of the adnexal mass and

  10. Performance evaluation of the Abbott CELL-DYN Emerald for use as a bench-top analyzer in a research setting.

    Science.gov (United States)

    Khoo, T-L; Xiros, N; Guan, F; Orellana, D; Holst, J; Joshua, D E; Rasko, J E J

    2013-08-01

    The CELL-DYN Emerald is a compact bench-top hematology analyzer that can be used for a three-part white cell differential analysis. To determine its utility for analysis of human and mouse samples, we evaluated this machine against the larger CELL-DYN Sapphire and Sysmex XT2000iV hematology analyzers. 120 human (normal and abnormal) and 30 mouse (normal and abnormal) samples were analyzed on both the CELL-DYN Emerald and CELL-DYN Sapphire or Sysmex XT2000iV analyzers. For mouse samples, the CELL-DYN Emerald analyzer required manual recalibration based on the histogram populations. Analysis of the CELL-DYN Emerald showed excellent precision, within accepted ranges (white cell count CV% = 2.09%; hemoglobin CV% = 1.68%; platelets CV% = 4.13%). Linearity was excellent (R² ≥ 0.99), carryover was minimal (laboratories or as a backup system in larger laboratories. © 2012 John Wiley & Sons Ltd.

  11. Mass Analyzers Facilitate Research on Addiction

    Science.gov (United States)

    2012-01-01

    The famous go/no go command for Space Shuttle launches comes from a place called the Firing Room. Located at Kennedy Space Center in the Launch Control Center (LCC), there are actually four Firing Rooms that take up most of the third floor of the LCC. These rooms comprise the nerve center for Space Shuttle launch and processing. Test engineers in the Firing Rooms operate the Launch Processing System (LPS), which is a highly automated, computer-controlled system for assembly, checkout, and launch of the Space Shuttle. LPS monitors thousands of measurements on the Space Shuttle and its ground support equipment, compares them to predefined tolerance levels, and then displays values that are out of tolerance. Firing Room operators view the data and send commands about everything from propellant levels inside the external tank to temperatures inside the crew compartment. In many cases, LPS will automatically react to abnormal conditions and perform related functions without test engineer intervention; however, firing room engineers continue to look at each and every happening to ensure a safe launch. Some of the systems monitored during launch operations include electrical, cooling, communications, and computers. One of the thousands of measurements derived from these systems is the amount of hydrogen and oxygen inside the shuttle during launch.

  12. A New Method for Re-Analyzing Evaluation Bias: Piecewise Growth Curve Modeling Reveals an Asymmetry in the Evaluation of Pro and Con Arguments.

    Directory of Open Access Journals (Sweden)

    Jens Jirschitzka

    Full Text Available In four studies we tested a new methodological approach to the investigation of evaluation bias. The usage of piecewise growth curve modeling allowed for investigation into the impact of people's attitudes on their persuasiveness ratings of pro- and con-arguments, measured over the whole range of the arguments' polarity from an extreme con to an extreme pro position. Moreover, this method provided the opportunity to test specific hypotheses about the course of the evaluation bias within certain polarity ranges. We conducted two field studies with users of an existing online information portal (Studies 1a and 2a as participants, and two Internet laboratory studies with mostly student participants (Studies 1b and 2b. In each of these studies we presented pro- and con-arguments, either for the topic of MOOCs (massive open online courses, Studies 1a and 1b or for the topic of M-learning (mobile learning, Studies 2a and 2b. Our results indicate that using piecewise growth curve models is more appropriate than simpler approaches. An important finding of our studies was an asymmetry of the evaluation bias toward pro- or con-arguments: the evaluation bias appeared over the whole polarity range of pro-arguments and increased with more and more extreme polarity. This clear-cut result pattern appeared only on the pro-argument side. For the con-arguments, in contrast, the evaluation bias did not feature such a systematic picture.

  13. Trajectories of bright stars at the Galactic Center as a tool to evaluate a graviton mass

    Directory of Open Access Journals (Sweden)

    Zakharov Alexander

    2016-01-01

    Full Text Available Scientists worked in Saint-Petersburg (Petrograd, Leningrad played the extremely important role in creation of scientific school and development of general relativity in Russia. Very recently LIGO collaboration discovered gravitational waves [1] predicted 100 years ago by A. Einstein. In the papers reporting about this discovery, the joint LIGO & VIRGO team presented an upper limit on graviton mass such as mg < 1.2 × 10−22eV [1, 2]. The authors concluded that their observational data do not show violations of classical general relativity because the graviton mass limit is very small. We show that an analysis of bright star trajectories could bound graviton mass with a comparable accuracy with accuracies reached with gravitational wave interferometers and expected with forthcoming pulsar timing observations for gravitational wave detection. This analysis gives an opportunity to treat observations of bright stars near the Galactic Center as a tool for an evaluation specific parameters of the black hole and also to obtain constraints on the fundamental gravity law such as a modifications of Newton gravity law in a weak field approximation. In that way, based on a potential reconstruction at the Galactic Center we give a bounds on a graviton mass.

  14. Evaluation of gas chromatography – electron ionization – full scan high resolution Orbitrap mass spectrometry for pesticide residue analysis

    Energy Technology Data Exchange (ETDEWEB)

    Mol, Hans G.J., E-mail: hans.mol@wur.nl; Tienstra, Marc; Zomer, Paul

    2016-09-07

    Gas chromatography with electron ionization and full scan high resolution mass spectrometry with an Orbitrap mass analyzer (GC-EI-full scan Orbitrap HRMS) was evaluated for residue analysis. Pesticides in fruit and vegetables were taken as an example application. The relevant aspects for GC-MS based residue analysis, including the resolving power (15,000 to 120,000 FWHM at m/z 200), scan rate, dynamic range, selectivity, sensitivity, analyte identification, and utility of existing EI-libraries, are assessed and discussed in detail. The optimum acquisition conditions in full scan mode (m/z 50–500) were a resolving power of 60,000 and an automatic-gain-control target value of 3E6. These conditions provided (i) an optimum mass accuracy: within 2 ppm over a wide concentration range, with/without matrix, enabling the use of ±5 ppm mass extraction windows (ii) adequate scan speed: minimum 12 scans/peak, (iii) an intra-scan dynamic range sufficient to achieve LOD/LOQs ≤0.5 pg in fruit/vegetable matrices (corresponding to ≤0.5 μg kg{sup −1}) for most pesticides. EI-Orbitrap spectra were consistent over a very wide concentration range (5 orders) with good match values against NIST (EI-quadrupole) spectra. The applicability for quantitative residue analysis was verified by validation of 54 pesticides in three matrices (tomato, leek, orange) at 10 and 50 μg/kg. The method involved a QuEChERS-based extraction with a solvent switch into iso-octane, and 1 μL hot splitless injection into the GC-HRMS system. A recovery between 70 and 120% and a repeatability RSD <10% was obtained in most cases. Linearity was demonstrated for the range ≤5–250 μg kg{sup −1}. The pesticides could be identified according to the applicable EU criteria for GC-HRMS (SANTE/11945/2015). GC-EI-full scan Orbitrap HRMS was found to be highly suited for quantitative pesticide residue analysis. The potential of qualitative screening to extend the scope makes it an attractive

  15. Evaluation of gas chromatography – electron ionization – full scan high resolution Orbitrap mass spectrometry for pesticide residue analysis

    International Nuclear Information System (INIS)

    Mol, Hans G.J.; Tienstra, Marc; Zomer, Paul

    2016-01-01

    Gas chromatography with electron ionization and full scan high resolution mass spectrometry with an Orbitrap mass analyzer (GC-EI-full scan Orbitrap HRMS) was evaluated for residue analysis. Pesticides in fruit and vegetables were taken as an example application. The relevant aspects for GC-MS based residue analysis, including the resolving power (15,000 to 120,000 FWHM at m/z 200), scan rate, dynamic range, selectivity, sensitivity, analyte identification, and utility of existing EI-libraries, are assessed and discussed in detail. The optimum acquisition conditions in full scan mode (m/z 50–500) were a resolving power of 60,000 and an automatic-gain-control target value of 3E6. These conditions provided (i) an optimum mass accuracy: within 2 ppm over a wide concentration range, with/without matrix, enabling the use of ±5 ppm mass extraction windows (ii) adequate scan speed: minimum 12 scans/peak, (iii) an intra-scan dynamic range sufficient to achieve LOD/LOQs ≤0.5 pg in fruit/vegetable matrices (corresponding to ≤0.5 μg kg"−"1) for most pesticides. EI-Orbitrap spectra were consistent over a very wide concentration range (5 orders) with good match values against NIST (EI-quadrupole) spectra. The applicability for quantitative residue analysis was verified by validation of 54 pesticides in three matrices (tomato, leek, orange) at 10 and 50 μg/kg. The method involved a QuEChERS-based extraction with a solvent switch into iso-octane, and 1 μL hot splitless injection into the GC-HRMS system. A recovery between 70 and 120% and a repeatability RSD <10% was obtained in most cases. Linearity was demonstrated for the range ≤5–250 μg kg"−"1. The pesticides could be identified according to the applicable EU criteria for GC-HRMS (SANTE/11945/2015). GC-EI-full scan Orbitrap HRMS was found to be highly suited for quantitative pesticide residue analysis. The potential of qualitative screening to extend the scope makes it an attractive alternative to

  16. Evaluation of the i-STAT Portable Clinical Analyzer for point-of-care blood testing in the intensive care units of a university children's hospital.

    Science.gov (United States)

    Papadea, Christine; Foster, Joyce; Grant, Sharon; Ballard, Sandra A; Cate, John C; Southgate, W Michael; Purohit, Dilip M

    2002-01-01

    We evaluated the analytical performance of the i-STAT Portable Clinical Analyzer (PCA), a point-of-care testing system consisting of a hand-held analyzer and single-use cartridges that measure different panels of electrolytes, metabolites, blood gases, and hematocrit in 65-100 microl of blood. Our objective was to determine whether PCA measurements at the bedside of patients in the neonatal and pediatric intensive care units of the MUSC Children's Hospital would be as reliable as those performed by the clinical laboratory's primary methods (Radiometer ABL 725 blood gas analyzer; Vitros 750 chemistry analyzer; and Coulter STKS hematology analyzer). Four cartridge types: (a) EC8+ (sodium; potassium; chloride; urea; glucose; pH; blood gases [PO2; pCO2]), (b) EC6+ (sodium; potassium; ionized calcium; glucose; hematocrit; pH), (c) G3+ (pH; PO2; pCO2), and (d) creatinine, were assessed for reproducibility, linearity, and method comparisons using aqueous samples, blood samples supplemented with several analytes, and -225 blood samples from patients. Reproducibility (CV) was good ( or < 3 mo) showed that agreement between the PCA and the primary methods was clinically acceptable. After the PCA was implemented for clinical testing, the observation of discrepant results of creatinine concentrations in neonatal blood samples that would have affected clinical management led to a second creatinine comparison study (59 additional samples) and to our eventual discontinuation of the PCA creatinine assay. This problem notwithstanding, the successful implementation of the PCA is attributed to careful analytical evaluations and ongoing communication with the clinical staff.

  17. Evaluation of body mass index as a prognostic factor in osteoarthrosis of the knee

    Directory of Open Access Journals (Sweden)

    Fabrício Bolpato Loures

    2016-08-01

    Full Text Available ABSTRACT OBJECTIVE: To evaluate the relationship between patients' body mass index (BMI and the degree of radiographic severity of knee osteoarthrosis. METHOD: 117 patients with gonarthrosis were evaluated prospectively. The patients' BMI was calculated and their knee arthrosis was classified in accordance with the modified Ahlbäck criteria. Kruskal-Wallis analysis of variance (ANOVA was used to evaluate the relationship between these two variables. RESULTS: The group classified as Ahlbäck grade V had significantly higher BMI than the others. CONCLUSION: There is a direct relationship between BMI and the degree of radiographic severity of gonarthrosis. Obesity appears to be directly related to the progression of knee osteoarthrosis.

  18. Long-term evaluation of a Canadian back pain mass media campaign.

    Science.gov (United States)

    Suman, Arnela; Bostick, Geoffrey P; Schopflocher, Donald; Russell, Anthony S; Ferrari, Robert; Battié, Michele C; Hu, Richard; Buchbinder, Rachelle; Gross, Douglas P

    2017-09-01

    This paper evaluates the long-term impact of a Canadian mass media campaign on general public beliefs about staying active when experiencing low back pain (LBP). Changes in beliefs about staying active during an episode of LBP were studied using telephone and web-based surveys. Logistic regression analysis was used to investigate changes in beliefs over time and the effect of exposure to campaign messaging. The percentage of survey respondents agreeing that they should stay active through LBP increased annually from 58.9 to ~72.0%. Respondents reporting exposure to campaign messaging were statistically significantly more likely to agree with staying active than respondents who did not report exposure to campaign messaging (adjusted OR, 95% CI = 1.96, 1.73-2.21). The mass media campaign had continued impact on public LBP beliefs over the course of 7 years. Improvements over time were associated with exposure to campaign messaging.

  19. Sterile insect technique: a field evaluation of the quality of mass-reared fruit flies

    International Nuclear Information System (INIS)

    1985-01-01

    To optimize the use of the sterile insect technique it is essential to establish precise programmes for the evaluation of mass-reared flies in comparison with the natural population. This video presents a programme carried out at the island of Prosida which represents an extremely favourable habitat for the development of the flies; the flies are a new strain mass-reared in the IAEA's Laboratory at Seibersdorf, Austria. The technique employed is the Marked Release Recapture Technique, which consists of colouring a predetermined number of flies with fluorescent powder before they are released, and then recapturing them. This method provides valuable data about the flies' adaptability, orientation to the habitat, motility, sexual activity and reproduction

  20. Endoscopic ultrasound elastography for evaluation of lymph nodes and pancreatic masses: a multicenter study

    DEFF Research Database (Denmark)

    Giovannini, Marc; Thomas, Botelberge; Erwan, Bories

    2009-01-01

    AIM: To evaluate the ability of endoscopic ultrasound (EUS) elastography to distinguish benign from malignant pancreatic masses and lymph nodes. METHODS: A multicenter study was conducted and included 222 patients who underwent EUS examination with assessment of a pancreatic mass (n = 121) or lymph...... node (n = 101). The classification as benign or malignant, based on the real time elastography pattern, was compared with the classification based on the B-mode EUS images and with the final diagnosis obtained by EUS-guided fine needle aspiration (EUS-FNA) and/or by surgical pathology. An interobserver...... study was performed. RESULTS: The sensitivity and specificity of EUS elastography to differentiate benign from malignant pancreatic lesions are 92.3% and 80.0%, respectively, compared to 92.3% and 68.9%, respectively, for the conventional B-mode images. The sensitivity and specificity of EUS...

  1. Sterile insect technique: a field evaluation of the quality of mass-reared fruit flies

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1986-12-31

    To optimize the use of the sterile insect technique it is essential to establish precise programmes for the evaluation of mass-reared flies in comparison with the natural population. This video presents a programme carried out at the island of Prosida which represents an extremely favourable habitat for the development of the flies; the flies are a new strain mass-reared in the IAEA`s Laboratory at Seibersdorf, Austria. The technique employed is the Marked Release Recapture Technique, which consists of colouring a predetermined number of flies with fluorescent powder before they are released, and then recapturing them. This method provides valuable data about the flies` adaptability, orientation to the habitat, motility, sexual activity and reproduction

  2. Optimization of on-line hydrogen stable isotope ratio measurements of halogen- and sulfur-bearing organic compounds using elemental analyzer-chromium/high-temperature conversion isotope ratio mass spectrometry (EA-Cr/HTC-IRMS).

    Science.gov (United States)

    Gehre, Matthias; Renpenning, Julian; Geilmann, Heike; Qi, Haiping; Coplen, Tyler B; Kümmel, Steffen; Ivdra, Natalija; Brand, Willi A; Schimmelmann, Arndt

    2017-03-30

    Accurate hydrogen isotopic analysis of halogen- and sulfur-bearing organics has not been possible with traditional high-temperature conversion (HTC) because the formation of hydrogen-bearing reaction products other than molecular hydrogen (H 2 ) is responsible for non-quantitative H 2 yields and possible hydrogen isotopic fractionation. Our previously introduced, new chromium-based EA-Cr/HTC-IRMS (Elemental Analyzer-Chromium/High-Temperature Conversion Isotope Ratio Mass Spectrometry) technique focused primarily on nitrogen-bearing compounds. Several technical and analytical issues concerning halogen- and sulfur-bearing samples, however, remained unresolved and required further refinement of the reactor systems. The EA-Cr/HTC reactor was substantially modified for the conversion of halogen- and sulfur-bearing samples. The performance of the novel conversion setup for solid and liquid samples was monitored and optimized using a simultaneously operating dual-detection system of IRMS and ion trap MS. The method with several variants in the reactor, including the addition of manganese metal chips, was evaluated in three laboratories using EA-Cr/HTC-IRMS (on-line method) and compared with traditional uranium-reduction-based conversion combined with manual dual-inlet IRMS analysis (off-line method) in one laboratory. The modified EA-Cr/HTC reactor setup showed an overall H 2 -recovery of more than 96% for all halogen- and sulfur-bearing organic compounds. All results were successfully normalized via two-point calibration with VSMOW-SLAP reference waters. Precise and accurate hydrogen isotopic analysis was achieved for a variety of organics containing F-, Cl-, Br-, I-, and S-bearing heteroelements. The robust nature of the on-line EA-Cr/HTC technique was demonstrated by a series of 196 consecutive measurements with a single reactor filling. The optimized EA-Cr/HTC reactor design can be implemented in existing analytical equipment using commercially available material and

  3. Endoscopic ultrasound elastography for evaluation of lymph nodes and pancreatic masses: a multicenter study.

    Science.gov (United States)

    Giovannini, Marc; Thomas, Botelberge; Erwan, Bories; Christian, Pesenti; Fabrice, Caillol; Benjamin, Esterni; Geneviève, Monges; Paolo, Arcidiacono; Pierre, Deprez; Robert, Yeung; Walter, Schimdt; Hanz, Schrader; Carl, Szymanski; Christoph, Dietrich; Pierre, Eisendrath; Jean-Luc, Van Laethem; Jacques, Devière; Peter, Vilmann; Andrian, Saftoiu

    2009-04-07

    To evaluate the ability of endoscopic ultrasound (EUS) elastography to distinguish benign from malignant pancreatic masses and lymph nodes. A multicenter study was conducted and included 222 patients who underwent EUS examination with assessment of a pancreatic mass (n = 121) or lymph node (n = 101). The classification as benign or malignant, based on the real time elastography pattern, was compared with the classification based on the B-mode EUS images and with the final diagnosis obtained by EUS-guided fine needle aspiration (EUS-FNA) and/or by surgical pathology. An interobserver study was performed. The sensitivity and specificity of EUS elastography to differentiate benign from malignant pancreatic lesions are 92.3% and 80.0%, respectively, compared to 92.3% and 68.9%, respectively, for the conventional B-mode images. The sensitivity and specificity of EUS elastography to differentiate benign from malignant lymph nodes was 91.8% and 82.5%, respectively, compared to 78.6% and 50.0%, respectively, for the B-mode images. The kappa coefficient was 0.785 for the pancreatic masses and 0.657 for the lymph nodes. EUS elastography is superior compared to conventional B-mode imaging and appears to be able to distinguish benign from malignant pancreatic masses and lymph nodes with a high sensitivity, specificity and accuracy. It might be reserved as a second line examination to help characterise pancreatic masses after negative EUS-FNA and might increase the yield of EUS-FNA for lymph nodes.

  4. Ultrasound for initial evaluation and triage of clinically suspicious soft-tissue masses

    International Nuclear Information System (INIS)

    Lakkaraju, A.; Sinha, R.; Garikipati, R.; Edward, S.; Robinson, P.

    2009-01-01

    Aim: To evaluate the efficacy of ultrasound as a first-line investigation in patients with a clinical soft-tissue mass. Methods: Three hundred and fifty-eight consecutive patients (155 male, 203 female, mean age 48 years) referred from primary and secondary care with soft-tissue masses underwent ultrasound evaluation. Five radiologists performed ultrasound using a 10-15 MHz linear transducer and recorded the referrer diagnosis, history, lesion size, anatomical location and depth, internal echogenicity, external margins (well-defined rim or infiltrative), and vascularity on power Doppler (absent or present, if present the pattern was listed as either linear or disorganized). A provisional ultrasound diagnosis was made using one of eight categories. Benign categories (categories 1-5) were referred back to a non-sarcoma specialist or original referrer for observation. Indeterminate or possible sarcomas (categories 6-8) were referred for magnetic resonance imaging (MRI) within 14 days. Additionally category 8 lesions were referred to the regional sarcoma service. Institutional and regional database follow-up was performed. Results: Two hundred and eighty-four of the 358 (79%) lesions were classified as benign (categories 1-5). On follow-up 15 of the 284 patients were re-referred but none (284/284) had a malignancy on follow-up (24-30 months). Overall at ultrasound 33 lesions were larger than 5 cm, 42 lesions were deep to deep fascia with 20 showing both features. In this subgroup of 95 patients there were six malignant tumours with the rest benign. Seventy-three of the 358 patients underwent MRI; the results of which indicated that there were 60 benign or non-tumours, 10 possible sarcomas, and three indeterminate lesions. Overall six of 12 (6/358, 1.68% of total patients) lesions deemed to represent possible sarcomas on imaging were sarcomas. Conclusion: Ultrasound is an effective diagnostic triage tool for the evaluation of soft-tissue masses referred from primary

  5. Use of a handheld, battery-operated chemistry analyzer for evaluation of heat-related symptoms in the backcountry of Grand Canyon National Park: a brief report.

    Science.gov (United States)

    Backer, H D; Collins, S

    1999-04-01

    To test the feasibility of using handheld, battery-operated chemical analyzers by EMS personnel in a wilderness environment to aid in the diagnosis and management of heat illness. During the summer of 1996, 3 portable clinical analyzers (i-STAT Corp, Princeton, NJ) were kept at different locations along the main hiking trail into the Grand Canyon. An operational protocol was designed for field use, and Park Service EMS personnel used the instruments at their discretion, primarily to determine serum sodium concentration and identify cases of hyponatremia. Data were collected on all EMS encounters. This study reviews our experience with the instruments. The i-STAT analyzer was used for 64 patients in the backcountry; of these uses, at least 22 were in the field and the remainder in backcountry ranger stations. Eight error messages were recorded in 6 patients. Subsequently, all but 1 had a successful determination. Among patients evacuated for further evaluation and care, serum sodium values were highly consistent with later analysis using standard laboratory equipment. The instrument was used in 31 (48%) of 64 of patients evaluated and released for self-treatment and self-evacuation, and 31 (36%) of 87 of patients evacuated by EMS personnel from the canyon. Nine cases of hyponatremia were confirmed in the field, allowing appropriate intervention. Portable clinical analyzers can reliably be used in a hot wilderness environment. In our application, it allowed identification of exercise-associated hyponatremia, an important cause of serious heat illness during endurance exercise in a hot environment. The results helped make treatment and disposition decisions.

  6. Risk of malignancy index in the preoperative evaluation of patients with ovarian masses

    International Nuclear Information System (INIS)

    Jabeen, R.; Khan, S.A.; Naveed, S.

    2015-01-01

    Objective: To evaluate the ability of RMI in preoperative discrimination of benign from malignant ovarian mass among women presenting at Nishtar Hospital Multan Pakistan. Methodology: It was a prospective study conducted at department of obstetrics/gynae Nishtar Hospital Multan between September 2008 to August 2009. 60 patients of more than 30 years of age admitted in gynaecology department for surgical exploration of ovarian mass were included. All the women in whom ovarian malignancy had already been diagnosed and admitted for second laparotomy were excluded. Results: The median age at presentation of ovarian malignancy is 56 years. The sensitivity of RMI in our group was 82.3%,the specificity was 88.3%, positive predictive value was 73.7% and the negative predictive value was 92.6%. Receiver operating curves reveal that RMI was a better diagnostic marker than CA-125 or ultrasound score alone for the prediction of malignancy in ovarian masses. Conclusion: The risk of malignancy index has high specificity and sensitivity. It yielded a better diagnostic performance as compared to CA-125 or ultrasound score alone in differentiating benign from malignant ovarian lesions. (author)

  7. Diagnostic performance of sonoelastographic Tsukuba score and strain ratio in evaluation of breast masses

    Directory of Open Access Journals (Sweden)

    Mahmoud Abd Elaziz Dawood

    2018-03-01

    Full Text Available The aim of this prospective study was to evaluate the diagnostic performance of the use of strain index ratio by sonoelastography to differentiate between benign and malignant breast lesions. Patients & Methods: This prospective study including 40 females, complaining of breast masses which were suspicious to be malignant on clinical examination. All patients were submitted to B-mode Ultrasound and sonoelastography. Biopsy as a gold standard and pathological study were done for all breast lesions. Results: US examination of every mass was done and categorized according to BI-RADS categories according to ACR2013, according to US lexicon. Sonoelastography examination with Lesions classification was performed on the basis of a 5-point scoring method proposed by Tsukuba elasticity score. Then measurements of strain ratio were done. Statistical analysis of combination of the three methods was sensitivity of 96.7%, specificity of 100% when we use cut off value of 3–4 in elastography score and ≤3 cut off value of strain ratio. Conclusion: The combined use of strain ratio with Tsukuba score and BI-RADS categorization increased the diagnostic performance in differentiation between benign and malignant breast lesions. Keywords: Elastography, Breast masses, Strain ratio, Ultrasound, BI-RADS classification, Tsukuba score

  8. Quantitative evaluation of small breast masses using a compartment model analysis on dynamic MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Ikeda, Osamu; Morishita, Shoji; Kido, Taeko; Kitajima, Mika; Okamura, Kenji; Fukuda, Seiji [Kumamoto Rosai Hospital, Yatsushiro (Japan); Yamashita, Yasuyuki; Takahashi, Mutsumasa

    1998-07-01

    To differentiate between malignant and benign breast masses using a compartmental analysis, 55 patients with breast masses (fibroadenoma, n=22; invasive ductal carcinoma, n=29; noninvasive ductal carcinoma, n=8) underwent Gd-DTPA enhanced dynamic MR imaging. Dynamic MR images obtained using two-dimensional fat-saturated fast multiplanar corrupted gradient echo technique over 10 minutes following bolus injection of Gd-DTPA. The triexponential concentration curve of Gd-DTPA was fitted to a theoretical model based on compartmental analysis. Using this method, the transfer constant (or permeability surface product per unit volume of component k) and f{sub 3}/f{sub 1}=f were measured, where f{sub 1} represents tumor vessel volume and f{sub 3} represents extracellular volume. The k value was significantly greater (p<0.01) for malignant tumors, and the k value seen in cases of noninvasive ductal carcinoma was less than that for invasive ductal carcinoma. The f value was significantly smaller (p<0.01) for malignant tumors, whereas the f value for noninvasive ductal carcinoma was not significantly different from that for invasive ductal carcinoma. We believe that this type of compartmental analysis may be of value for the evaluation of breast masses. (author)

  9. Multi-site, multi-country evaluation of analytical and operational performance of a low-mid volume chemiluminescent immunoassay analyzer.

    Science.gov (United States)

    De Keijzer, M H; Perkins, S; Motta, V; Morelli, D; Cristol, J P; Dupuy, A M; Hong, Y; Watanabe, S; Waerdt, C; Grunewald, R W

    2009-01-01

    A new automated immunoassay low-mid volume (beta-hCG, BNP, and CK-MB) and the time required to complete workloads of 50 and 100 tests with a mixture of 75% routine tests and 25% stat tests was also evaluated. Total precision was typically market and in use for an existing high volume immunoassay system. Stat turn around times were consistent with the fixed analytical time of 15.6 minutes and met the expectations of the laboratories. Measured test throughput ranged from 47 - 54 tests per hour and demonstrated that the analyzer was fit for the intended purpose of supporting a laboratory that performs suitable for use.

  10. A new qualitative pattern classification of shear wave elastograghy for solid breast mass evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Cong, Rui, E-mail: congrui2684@163.com; Li, Jing, E-mail: lijing@sj-hospital.org; Guo, Song, E-mail: 21751735@qq.com

    2017-02-15

    Highlights: • Qualitative SWE classification proposed here was significantly better than quantitative SWE parameters. • Qualitative classification proposed here was better than the classification proposed before. • Qualitative classification proposed here could obtain higher specificity without a loss of sensitivity. - Abstract: Objectives: To examine the efficacy of qualitative shear wave elastography (SWE) in the classification and evaluation of solid breast masses, and to compare this method with conventional ultrasonograghy (US), quantitative SWE parameters and qualitative SWE classification proposed before. Methods: From April 2015 to March 2016, 314 consecutive females with 325 breast masses who decided to undergo core needle biopsy and/or surgical biopsy were enrolled. Conventional US and SWE were previously performed in all enrolled subjects. Each mass was classified by two different qualitative classifications. One was established in our study, herein named the Qual1. Qual1 could classify the SWE images into five color patterns by the visual evaluations: Color pattern 1 (homogeneous pattern); Color pattern 2 (comparative homogeneous pattern); Color pattern 3 (irregularly heterogeneous pattern); Color pattern 4 (intralesional echo pattern); and Color pattern 5 (the stiff rim sign pattern). The second qualitative classification was named Qual2 here, and included a four-color overlay pattern classification (Tozaki and Fukuma, Acta Radiologica, 2011). The Breast Imaging Reporting and Data System (BI-RADS) assessment and quantitative SWE parameters were recorded. Diagnostic performances of conventional US, SWE parameters, and combinations of US and SWE parameters were compared. Results: With pathological results as the gold standard, of the 325 examined breast masses, 139 (42.77%) samples were malignant and 186 (57.23%) were benign. The Qual1 showed a higher Az value than the Qual2 and quantitative SWE parameters (all P < 0.05). When applying Qual1

  11. A new qualitative pattern classification of shear wave elastograghy for solid breast mass evaluation

    International Nuclear Information System (INIS)

    Cong, Rui; Li, Jing; Guo, Song

    2017-01-01

    Highlights: • Qualitative SWE classification proposed here was significantly better than quantitative SWE parameters. • Qualitative classification proposed here was better than the classification proposed before. • Qualitative classification proposed here could obtain higher specificity without a loss of sensitivity. - Abstract: Objectives: To examine the efficacy of qualitative shear wave elastography (SWE) in the classification and evaluation of solid breast masses, and to compare this method with conventional ultrasonograghy (US), quantitative SWE parameters and qualitative SWE classification proposed before. Methods: From April 2015 to March 2016, 314 consecutive females with 325 breast masses who decided to undergo core needle biopsy and/or surgical biopsy were enrolled. Conventional US and SWE were previously performed in all enrolled subjects. Each mass was classified by two different qualitative classifications. One was established in our study, herein named the Qual1. Qual1 could classify the SWE images into five color patterns by the visual evaluations: Color pattern 1 (homogeneous pattern); Color pattern 2 (comparative homogeneous pattern); Color pattern 3 (irregularly heterogeneous pattern); Color pattern 4 (intralesional echo pattern); and Color pattern 5 (the stiff rim sign pattern). The second qualitative classification was named Qual2 here, and included a four-color overlay pattern classification (Tozaki and Fukuma, Acta Radiologica, 2011). The Breast Imaging Reporting and Data System (BI-RADS) assessment and quantitative SWE parameters were recorded. Diagnostic performances of conventional US, SWE parameters, and combinations of US and SWE parameters were compared. Results: With pathological results as the gold standard, of the 325 examined breast masses, 139 (42.77%) samples were malignant and 186 (57.23%) were benign. The Qual1 showed a higher Az value than the Qual2 and quantitative SWE parameters (all P < 0.05). When applying Qual1

  12. A model for evaluating beef cattle rations considering effects of ruminal fiber mass

    Directory of Open Access Journals (Sweden)

    Douglas Sampaio Henrique

    2011-11-01

    Full Text Available A mathematical model based on Cornell Net Carbohydrate and Protein System (CNCPS was developed and adapted in order to evaluate beef cattle rations at tropical climate conditions. The presented system differs from CNCPS in the modeling of insoluble particles' digestion and passage kinetics, which enabled the estimation of fiber mass in rumen and its effects on animal performance. The equations used to estimate metabolizable protein and net energy requirements for gain, net energy requirement for maintenance and total efficiency of metabolizable energy utilization were obtained from scientific articles published in Brazil. The parameters of the regression equations in these papers were estimated using data from Bos indicus purebred and crossbred animals reared under tropical conditions. The model was evaluated by using a 368-piece of information database originally published on 11 Doctoral theses, 14 Master's dissertations and four scientific articles. Outputs of the model can be considered adequate.

  13. PhosphoSiteAnalyzer

    DEFF Research Database (Denmark)

    Bennetzen, Martin V; Cox, Jürgen; Mann, Matthias

    2012-01-01

    an algorithm to retrieve kinase predictions from the public NetworKIN webpage in a semiautomated way and applies hereafter advanced statistics to facilitate a user-tailored in-depth analysis of the phosphoproteomic data sets. The interface of the software provides a high degree of analytical flexibility......Phosphoproteomic experiments are routinely conducted in laboratories worldwide, and because of the fast development of mass spectrometric techniques and efficient phosphopeptide enrichment methods, researchers frequently end up having lists with tens of thousands of phosphorylation sites...... and is designed to be intuitive for most users. PhosphoSiteAnalyzer is a freeware program available at http://phosphosite.sourceforge.net ....

  14. Evaluations of particulate mass loading from visibility observations and atmospheric turbidity measurements: Pt. 1

    International Nuclear Information System (INIS)

    Tomasi, C.; Vitale, V.

    1984-01-01

    Two extinction models for continental and rural particles were defined by using a very accurate computer programme based on Mie extinction theory for spherical particles. The first extinction model gives several sets of volume extinction coefficients at seven visible and near-infra-red wave-lengths, calculated for twenty-seven Junge-type size distribution curves (with Junge parameter ranging from 1.8 to 4.4) and for eight relative-humidity values of the air. This model also gives the corresponding values of Aangstroem's exponent α and mean particle mass. The second extinction model gives similar sets of data, calculated for two log-normal size distribution curves of tropospheric and large rural particles at five relative-humidity values of the air. These monomodal models can be used to determine bimodal extinction models consisting of variable number fractions of tropospherics and rural particles. Evaluations of the particulate mass loading can be obtained from measurements of visual range and atmospheric turbidity, choosing the most appropriate extinction model on the basis of the spectral features characterizing atmospheric attenuation. Measurements of visibility and atmospheric turbidity in two rural localities of the Po valley were examined by employing both the present extinction models and other extinction models commonly used. The comparison of the results shows that the Junge-type extinction model can be reliably used in cases in which the exponent Junge-type extinction model and bimodal model were found to give realistic evaluations of the lower and upper limits of particulate mass loading

  15. Ultrasonographic evaluation of the calf muscle mass and architecture in elderly patients with and without sarcopenia.

    Science.gov (United States)

    Kuyumcu, Mehmet Emin; Halil, Meltem; Kara, Özgür; Çuni, Bledjan; Çağlayan, Gökhan; Güven, Serdar; Yeşil, Yusuf; Arık, Güneş; Yavuz, Burcu Balam; Cankurtaran, Mustafa; Özçakar, Levent

    2016-01-01

    To sonographically assess the muscle mass and architecture of sarcopenic elderly subjects, and to explore the utility of ultrasound (US) measurements in predicting sarcopenia. One hundred elderly subjects were enrolled in this cross-sectional study. Mean age value of our study population was 73.08±6.18years. The diagnosis of sarcopenia was confirmed by measuring fat-free mass index (using bioelectrical impedance analysis) and handgrip strength. Calf circumference was measured and US evaluations comprised bilateral gastrocnemius muscle (MG) thickness, fascicle length and pennate angles; subcutaneous fat and dermis thicknesses in the calf. Bilateral muscle thickness and fascicle length values were significantly lower in patients with sarcopenia (both psarcopenia (all values>76.92%). Gastrocnemius muscle thickness and fascicle length values are lower in sarcopenic elderly and these two parameters can serve as alternative measurements for predicting/quantifying sarcopenia. Calf circumference measurements alone may not be appropriate for assessing sarcopenia. Instead, US imaging can conveniently be used to evaluate different compartments of the musculoskelal system in (sarcopenic) elderly. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  16. Evaluation of mass absorption in LiBr flat-fan sheets

    International Nuclear Information System (INIS)

    Palacios, E.; Izquierdo, M.; Marcos, J.D.; Lizarte, R.

    2009-01-01

    Experiments were conducted to determine the absorption rates of refrigerant vapour in an aqueous lithium bromide flat-fan sheet for use in absorption air-conditioning systems. The solution flow rates tested ranged from 0.023 to 0.054 kg/s (84-194 kg/h), with pressure losses in the injection nozzle of from 40 to 250 kPa. The effect of the mass flow rate on both solution residence time and the sheet deformation rate was also analyzed in absorption chambers of a pre-defined length, along with the effect of the sub-cooling temperature on the amount of vapour absorbed. The downstream evolution of approach to equilibrium factor F was quantified. The mass transfer coefficient values were found to be over 3 x 10 -4 m/s. In absorption chambers 100 mm long, over 0.8 g/s l of vapour were absorbed per chamber absorption volume. Moreover, about 600 g of vapour were absorbed per kJ of solution flow work. Flat-fan sheet configurations were found to perform better than falling film and spray absorbers.

  17. Evaluation of the agreement among three handheld blood glucose meters and a laboratory blood analyzer for measurement of blood glucose concentration in Hispaniolan Amazon parrots (Amazona ventralis).

    Science.gov (United States)

    Acierno, Mark J; Mitchell, Mark A; Schuster, Patricia J; Freeman, Diana; Sanchez-Migallon Guzman, David; Tully, Thomas N

    2009-02-01

    To determine the degree of agreement between 3 commercially available point-of-care blood glucose meters and a laboratory analyzer for measurement of blood glucose concentrations in Hispaniolan Amazon parrots (Amazona ventralis). 20 healthy adult Hispaniolan Amazon parrots. A 26-gauge needle and 3-mL syringe were used to obtain a blood sample (approx 0.5 mL) from a jugular vein of each parrot. Small volumes of blood (0.6 to 1.5 microL) were used to operate each of the blood glucose meters, and the remainder was placed into lithium heparin microtubes and centrifuged. Plasma was harvested and frozen at -30 degrees C. Within 5 days after collection, plasma samples were thawed and plasma glucose concentrations were measured by means of the laboratory analyzer. Agreement between pairs of blood glucose meters and between each blood glucose meter and the laboratory analyzer was evaluated by means of the Bland-Altman method, and limits of agreement (LOA) were calculated. None of the results of the 3 blood glucose meters agreed with results of the laboratory analyzer. Each point-of-care blood glucose meter underestimated the blood glucose concentration, and the degree of negative bias was not consistent (meter A bias, -94.9 mg/dL [LOA, -148.0 to -41.7 mg/dL]; meter B bias, -52 mg/dL [LOA, -107.5 to 3.5 mg/dL]; and meter C bias, -78.9 mg/dL [LOA, -137.2 to -20.6 mg/dL]). On the basis of these results, use of handheld blood glucose meters in the diagnosis or treatment of Hispaniolan Amazon parrots and other psittacines cannot be recommended.

  18. Methodology and resources for the evaluation of the construction of knowledge about the concept of density and specific mass

    OpenAIRE

    Tânia Inácio de Oliveira; Nádia Vilela Pereira; Cláudio Boghi; Juliano Schimiguel; Dorlivete Moreira Shitsuka

    2017-01-01

    Abstract: The teaching of physics concepts involves the construction of knowledge in the students' minds. The aim of this article is to present a case report of teaching density and specific mass concepts in high school technical education classes. The study analyzes the results of the construction of methodology and development of a product so that teachers of Physics can give their students the construction of the concept of density of objects and the specific mass of the substances and per...

  19. Technetium-99m methylene diphosphonate scintimammography for evaluation of palpable breast masses

    International Nuclear Information System (INIS)

    Shah, S.; Khan, M.M.; Khan, A.U.; Khan, S.M.; Khan, A.A.

    2002-01-01

    Objective:To evaluate technetium-99m methylene diphosphonate (/sup 99m/Tc-MDP) as a noninvasive tumor-localizing agent in patients with palpable breast masses and to differentiate malignant from benign breast lesions. Design: It was an observational and experimental study. Place and Duration of Study: the study was conducted at the Institute of Radiotherapy and Nuclear Medicine (IRNUM), Peshawar during a six-month period (June to November, 1995). Subjects and Methods: 99m Tc-MDP scintimammography (SMM) was performed in thirty patients with palpable breast masses (Group A). Ten patients with no palpable breast abnormality (Group B) also underwent /sup 99m/Tc-MDP breast study; they served as controls. Upright anterior, lateral and oblique lateral images of the breasts were acquired 10-30 minutes after intravenous injection of 740 MBq of /sup 99m/Tc-MDP. This was performed during routine bone scanning. SMM was followed by surgical and /or needle biopsy. Results: breast cancer was histologically diagnosed in twenty two (73%), and benign disease found in eight patients (27%). Of the twenty two breast carcinomas, twenty (91%) were detected using /sup 99m/Tc-MDP SMM, while no uptake was seen in two (9%). Of the eight patients with pathologically proven benign breast lesions, seven (88%) either did not show any uptake or showed faint bilateral accumulation. Focal /sup 99m/Tc-MDP uptake was observed in one fibroadenoma. Conclusion: The study showed that SMM with /sup 99m/Tc-MDP is positive in a high percentage of patients with carcinoma of the breast and may differentiate malignant from benign masses. (author)

  20. Evaluation of a High Resolving Power Time-of-Flight Mass Spectrometer for Drug Analysis in Terms of Resolving Power and Acquisition Rate

    Science.gov (United States)

    Pelander, Anna; Decker, Petra; Baessmann, Carsten; Ojanperä, Ilkka

    2011-02-01

    Liquid chromatography time-of-flight mass spectrometry (LC-TOFMS) is applied increasingly to various fields of small molecule analysis. The moderate resolving power (RP) of standard TOFMS instruments poses a risk of false negative results when complex biological matrices are to be analyzed. In this study, the performance of a high resolving power TOFMS instrument (maXis by Bruker Daltonik, Bremen, Germany) was evaluated for drug analysis. By flow injection analysis of critical drug mixtures, including a total of 17 compounds with nominal masses of 212-415 Da and with mass differences of 8.8-23.5 mDa, RP varied from 34,400 to 51,900 (FWHM). The effect of acquisition rate on RP, mass accuracy, and isotopic pattern fit was studied by applying 1, 2, 5, 10, and 20 Hz acquisition rates in a 16 min gradient elution LC separation. All three variables were independent of the acquisition rate, with an average mass accuracy and isotopic pattern fit factor (mSigma) of 0.33 ppm and 5.9, respectively. The average relative standard deviation of RP was 1.8%, showing high repeatability. The performance was tested further with authentic urine extracts containing a co-eluting compound pair with a nominal mass of 296 Da and an 11.2 mDa mass difference. The authentic sample components were readily resolved and correctly identified by the automated data analysis. The average RP, mass accuracy, and isotopic pattern fit were 36,600, 0.9 ppm, and 7.3 mSigma, respectively.

  1. Sonographic evaluation of plantar fasciitis and relation to body mass index

    Energy Technology Data Exchange (ETDEWEB)

    Ozdemir, Huseyin [Department of Radiology Firat University, Faculty of Medicine, Elazig 23119 (Turkey)]. E-mail: ozdemir@firat.edu.tr; Yilmaz, Erhan [Department Orthopedic Firat University, Faculty of Medicine, Elazig (Turkey); Murat, Ayse [Department of Radiology Firat University, Faculty of Medicine, Elazig 23119 (Turkey); Karakurt, Lokman [Department Orthopedic Firat University, Faculty of Medicine, Elazig (Turkey); Poyraz, A. Kursad [Department of Radiology Firat University, Faculty of Medicine, Elazig 23119 (Turkey); Ogur, Erkin [Department of Radiology Firat University, Faculty of Medicine, Elazig 23119 (Turkey)

    2005-06-01

    Purpose: We have investigated the role of sonography in the diagnosis of plantar fasciitis. Materials and methods: This study evaluates 39 patients with plantar fasciitis and control group of 22 healthy volunteers. The plantar fascia thickness was measured 5 mm distal to the insertion of the calcaneus of plantar aponeurosis. Qualitative parameters such as decreased echogenity, biconvexity, perifascial fluid and calcification of plantar fascia were also noted. Results: Mean plantar fascia thickness was measured 2.9 mm in patients with unilateral heel pain, 2.2 mm for contralateral normal heel and 2.5 mm for control group. There was a statistically significant difference between heel with plantar fasciitis, contralateral normal heel and control groups (p = 0.009 and 0.0001, respectively). Mean body mass index was 28 kg/m{sup 2} in patients with heel pain and 25 kg/m{sup 2} in control group. Body mass index measurements were significantly different between plantar fasciitis and control groups. We found reduced plantar fascia echogenity in 16 cases (41%), calcaneal spur in 20 cases (51%), biconvex appearance in two cases (5.1%) and perifascial fluid in one case (2.5%). Conclusion: We conclude that in patients with plantar fasciitis, ultrasound may detect relatively small differences in plantar fascia thickness even in clinically unequivocal plantar fasciitis.

  2. Sonographic evaluation of plantar fasciitis and relation to body mass index

    International Nuclear Information System (INIS)

    Ozdemir, Huseyin; Yilmaz, Erhan; Murat, Ayse; Karakurt, Lokman; Poyraz, A. Kursad; Ogur, Erkin

    2005-01-01

    Purpose: We have investigated the role of sonography in the diagnosis of plantar fasciitis. Materials and methods: This study evaluates 39 patients with plantar fasciitis and control group of 22 healthy volunteers. The plantar fascia thickness was measured 5 mm distal to the insertion of the calcaneus of plantar aponeurosis. Qualitative parameters such as decreased echogenity, biconvexity, perifascial fluid and calcification of plantar fascia were also noted. Results: Mean plantar fascia thickness was measured 2.9 mm in patients with unilateral heel pain, 2.2 mm for contralateral normal heel and 2.5 mm for control group. There was a statistically significant difference between heel with plantar fasciitis, contralateral normal heel and control groups (p = 0.009 and 0.0001, respectively). Mean body mass index was 28 kg/m 2 in patients with heel pain and 25 kg/m 2 in control group. Body mass index measurements were significantly different between plantar fasciitis and control groups. We found reduced plantar fascia echogenity in 16 cases (41%), calcaneal spur in 20 cases (51%), biconvex appearance in two cases (5.1%) and perifascial fluid in one case (2.5%). Conclusion: We conclude that in patients with plantar fasciitis, ultrasound may detect relatively small differences in plantar fascia thickness even in clinically unequivocal plantar fasciitis

  3. An Interlaboratory Evaluation of Drift Tube Ion Mobility–Mass Spectrometry Collision Cross Section Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Stow, Sarah M. [Department; Causon, Tim J. [Division; Zheng, Xueyun [Biological; Kurulugama, Ruwan T. [Agilent Technologies, Santa Clara, California 95051, United States; Mairinger, Teresa [Division; May, Jody C. [Department; Rennie, Emma E. [Agilent Technologies, Santa Clara, California 95051, United States; Baker, Erin S. [Biological; Smith, Richard D. [Biological; McLean, John A. [Department; Hann, Stephan [Division; Fjeldsted, John C. [Agilent Technologies, Santa Clara, California 95051, United States

    2017-08-14

    Collision cross section (CCS) measurements resulting from ion mobility-mass spectrometry (IM-MS) experiments provide a promising orthogonal dimension of structural information in MS-based analytical separations. As with any molecular identifier, interlaboratory standardization must precede broad range integration into analytical workflows. In this study, we present a reference drift tube ion mobility mass spectrometer (DTIM-MS) where improvements on the measurement accuracy of experimental parameters influencing IM separations provide standardized drift tube, nitrogen CCS values (DTCCSN2) for over 120 unique ion species with the lowest measurement uncertainty to date. The reproducibility of these DTCCSN2 values are evaluated across three additional laboratories on a commercially available DTIM-MS instrument. The traditional stepped field CCS method performs with a relative standard deviation (RSD) of 0.29% for all ion species across the three additional laboratories. The calibrated single field CCS method, which is compatible with a wide range of chromatographic inlet systems, performs with an average, absolute bias of 0.54% to the standardized stepped field DTCCSN2 values on the reference system. The low RSD and biases observed in this interlaboratory study illustrate the potential of DTIM-MS for providing a molecular identifier for a broad range of discovery based analyses.

  4. $K^{0}-\\overline{K}^{0}$ mass and decay-width differences CPLEAR evaluation

    CERN Document Server

    Angelopoulos, Angelos; Aslanides, Elie; Backenstoss, Gerhard; Bargassa, P; Behnke, O; Benelli, A; Bertin, V; Blanc, F; Bloch, P; Carlson, P J; Carroll, M; Cawley, E; Chertok, M B; Danielsson, M; Dejardin, M; Derré, J; Ealet, A; Eleftheriadis, C; Fetscher, W; Fidecaro, Maria; Filipcic, A; Francis, D; Fry, J; Gabathuler, Erwin; Gamet, R; Gerber, H J; Go, A; Haselden, A; Hayman, P J; Henry-Coüannier, F; Hollander, R W; Jon-And, K; Kettle, P R; Kokkas, P; Kreuger, R; Le Gac, R; Leimgruber, F; Mandic, I; Manthos, N; Marel, Gérard; Mikuz, M; Miller, J; Montanet, François; Müller, A; Nakada, Tatsuya; Pagels, B; Papadopoulos, I M; Pavlopoulos, P; Polivka, G; Rickenbach, R; Roberts, B L; Ruf, T; Schäfer, M; Schaller, L A; Schietinger, T; Schopper, A; Tauscher, Ludwig; Thibault, C; Touchard, F; Touramanis, C; van Eijk, C W E; Vlachos, S; Weber, P; Wigger, O; Wolter, M; Zavrtanik, D; Zimmerman, D

    1999-01-01

    The CPT-violation parameters \\redd\\ and \\imd\\ determined recently by CPLEAR are used to evaluate the \\kn --\\knb\\ mass and decay-width differences, as given by the difference between the diagonal elements of the neutral-kaon mixing matrix $({\\mathrm M}-\\i\\Gamma/2)$. The results --- $({\\mathrm M}_{\\kn\\kn}-{\\mathrm M}_{\\knb\\knb}) = ( -1.5 \\pm 2.0 )\\times10^{-18}$ \\gev\\ and $(\\Gamma_{\\kn\\kn}-\\Gamma_{\\knb\\knb}) = ( 3.9 \\pm 4.2 )\\times 10^{-18}$ \\gev\\ --- are consistent with CPT invariance. The CPT invariance is also shown to hold within a few times $10^{-3}-10^{-4}$ for many of the amplitudes describing neutral-kaon decays to different final states.

  5. The evaluation of the mass distribution data for 238U, 239Pu and 242Pu fission

    International Nuclear Information System (INIS)

    Liu Tingjin

    2002-01-01

    The mass distribution data for 238 U at E n =1.5, 5.5, 8.3, 11.3, 14.9, 22.0, 27.5, 50.0, 99.5, 160.0 MeV, E p =20.0, 60.0 MeV 239 Pu at E n =0.17, 7.9, 14.5 MeV and 242 Pu at E n =15.1 MeV were evaluated and recommended based on the main available experimental data up to now. The experimental data were make necessary corrections and their errors were also made necessary adjustments. The problems concerned were discussed

  6. Usefulness of enteral contrast media in MR evaluation of pelvic mass

    International Nuclear Information System (INIS)

    Kim, Hun; Kim, Jung Sik; Kim, Hong; Shon, Chul Ho; Lee, Hee Jung; Lee, Sung Moon; Woo, Sung Ku; Suh, Soo Jhi

    1999-01-01

    To assess the value of enteral contrast media for the evaluation of pelvic masses by MR imaging. Between April and July 1998, 16 women with pelvic masses were examined by MRI. The origin of the lesion was the ovary in twelve cases, the uterus in three, and the sigmoid in one. Using a 1.5T scanner(Magnetom Vision, Siemens), T1-weighted axial spin echo(SE), T2-weighted turbo spin echo(TSE), two dimensional fast low-angle shot(FLASH 2D), and half-Fourier TSE(HASTE) images were obtained in all patients after the administration of Magnevist Enteral (Shering, Berlin, Germany). In each MR imagine sequence, distinction between the lesion and adjacent bowel (1, not distinguished; 2, partly distinguished; 3, clearly distinguished), artifact (0, absent; 1, mild; 2, severe), image quality (1, poor; 2, fair; 3, good), were compared before and after the use of enteral contrast media. Changes in MRI impression after the use of enteral contrast media were also evaluated. Two radiologists reached a consensus after reviewing the images. Statistical significance was determined by Wilcoxon's signed ranked test. For distinguishing lesions, SE T1WI and FLASH 2D with enteral contrast media were significantly superior to SE T1WI without enteral contrast media (p < 0.05). With regard to image quality, FLASH 2D and HASTE, both with enteral contrast media, were significantly superior to SE T1WI and TSE T2WI, respectively, both without enteral contrast media (p < 0.05). Artefacts were more frequently found after the application of enteral contrast media in conventional sequences but were not present in breathhold sequences. In two patients, MRI impression changed after the application of enteral contrast media. In a limited number of cases, enteral contrast media improved lesion detection, image quality and diagnostic accuracy when breathhold fast MR imaging was applied

  7. The pitfalls of ultrasonography in the evaluation of soft tissue masses

    International Nuclear Information System (INIS)

    Kwok, Henry CK.; Pinto, Clinton H.; Doyle, Anthony J.

    2012-01-01

    Ultrasonography is associated with a high error rate in the evaluation of soft tissue masses. The purposes of this study were to examine the nature of the diagnostic errors and to identify areas in which reporting could be improved. Patients who had soft tissue tumours and received ultrasonography during a 10-year period (1999–2009) were identified from a local tumour registry. The sonographic and pathological diagnoses were categorised as either ‘benign’ or ‘non-benign’. The accuracy of ultrasonography was assessed by correlating the sonographic with the pathological diagnostic categories. Recommendations from radiologists, where offered, were assessed for their appropriateness in the context of the pathological diagnosis. One hundred seventy-five patients received ultrasonography, of which 60 had ‘non-benign’ lesions and 115 had ‘benign’ lesions. Ultrasonography correctly diagnosed 35 and incorrectly diagnosed seven of the 60 ‘non-benign’ cases, and did not suggest a diagnosis in 18 cases. Most of the diagnostic errors related to misdiagnosing soft tissue tumours as haematomas (four out of seven). Recommendations for further management were offered by the radiologists in 144 cases, of which 52 had ‘non-benign’ pathology. There were eight ‘non-benign’ cases where no recommendation was offered, and the sonographic diagnosis was either incorrect or unavailable. Ultrasonography lacks accuracy in the evaluation of soft tissue masses. Ongoing education is required to improve awareness of the limitations with its use. These limitations should be highlighted to the referrers, especially those who do not have specific training in this area.

  8. Greenland ice sheet surface mass balance: evaluating simulations and making projections with regional climate models

    Directory of Open Access Journals (Sweden)

    J. G. L. Rae

    2012-11-01

    Full Text Available Four high-resolution regional climate models (RCMs have been set up for the area of Greenland, with the aim of providing future projections of Greenland ice sheet surface mass balance (SMB, and its contribution to sea level rise, with greater accuracy than is possible from coarser-resolution general circulation models (GCMs. This is the first time an intercomparison has been carried out of RCM results for Greenland climate and SMB. Output from RCM simulations for the recent past with the four RCMs is evaluated against available observations. The evaluation highlights the importance of using a detailed snow physics scheme, especially regarding the representations of albedo and meltwater refreezing. Simulations with three of the RCMs for the 21st century using SRES scenario A1B from two GCMs produce trends of between −5.5 and −1.1 Gt yr−2 in SMB (equivalent to +0.015 and +0.003 mm sea level equivalent yr−2, with trends of smaller magnitude for scenario E1, in which emissions are mitigated. Results from one of the RCMs whose present-day simulation is most realistic indicate that an annual mean near-surface air temperature increase over Greenland of ~ 2°C would be required for the mass loss to increase such that it exceeds accumulation, thereby causing the SMB to become negative, which has been suggested as a threshold beyond which the ice sheet would eventually be eliminated.

  9. Evaluation of mass spectrometry of urinary proteins and peptides as biomarkers for cats at risk of developing azotemia.

    Science.gov (United States)

    Jepson, Rosanne E; Coulton, Gary R; Cowan, Matthew L; Markwell, Peter; Syme, Harriet M; Elliott, Jonathan

    2013-02-01

    To evaluate proteomic delineation of feline urine by mass spectrometry as a method for identifying biomarkers in cats at risk of developing azotemia. Urine samples from geriatric cats (> 9 years old) with chronic kidney disease and nonazotemic cats that either remained nonazotemic (n = 10) or developed azotemia (10) within 1 year. Optimization studies with pooled urine were performed to facilitate the use of surface enhanced laser desorption-ionization time-of-flight mass spectrometry (SELDI-TOF-MS) for analysis of the urinary proteome of cats. Urine samples from nonazotemic cats at entry to the study were analyzed via SELDI-TOF-MS with weak cation exchange and strong anion exchange arrays. Spectral data were compared to identify biomarkers for development of azotemia. Low protein concentration in feline urine precluded direct application to array surfaces, and a buffer exchange and concentration step was required prior to SELDI-TOF-MS analysis. Three preparation conditions by use of weak cation and strong anion exchange arrays were selected on the basis of optimization studies for detection of biomarkers. Eight potential biomarkers with an m/z of 2,822, 9,886, 10,033, 10,151, 10,234, 11,653, 4,421, and 9,505 were delineated. SELDI-TOF-MS can be used to detect urinary low-molecular weight peptides and proteins that may represent biomarkers for early detection of renal damage. Further study is required to purify and identify potential biomarkers before their use in a clinical setting.

  10. Detailed evaluation of the natural circulation mass flow rate of water propelled by using an air injection

    International Nuclear Information System (INIS)

    Park, Rae-Joon; Ha, Kwang-Soon; Kim, Jae-Cheol; Hong, Seong-Wan; Kim, Sang-Baik

    2008-01-01

    One-dimensional (1D) air-water two-phase natural circulation flow in the thermohydraulic evaluation of reactor cooling mechanism by external self-induced flow - one-dimensional' (THERMES-1D) experiment has been verified and evaluated by using the RELAP5/MOD3 computer code. Experimental results on the 1D natural circulation mass flow rate of water propelled by using an air injection have been evaluated in detail. The RELAP5 results have shown that an increase in the air injection rate to 50% of the total heat flux leads to an increase in the water circulation mass flow rate. However, an increase in the air injection rate from 50 to 100% does not affect the water circulation mass flow rate, because of the inlet area condition. As the height increases in the air injection part, the void fraction increases. However, the void fraction in the upper part of the air injector maintains a constant value. An increase in the air injection mass flow rate leads to an increase in the local void fraction, but it has no influence on the local pressure. An increase in the coolant inlet area leads to an increase in the water circulation mass flow rate. However, the water outlet area does not have an influence on the water circulation mass flow rate. As the coolant outlet moves to a lower position, the water circulation mass flow rate decreases. (author)

  11. Evaluation of the performance and response of the bacharach TLV sniffer and H-Nu photoionization gas analyzer to common hydrocarbon solvents.

    Science.gov (United States)

    Chelton, C F; Zakraysek, N; Lautner, G M; Confer, R G

    1983-10-01

    Two direct reading instruments, the H-Nu PI 101 photoionization analyzer and the J.W. Bacharach TLV Sniffer, were evaluated under laboratory conditions to determine their performance characteristics when challenged by vapors of common hydrocarbon solvent mixtures. Each instrument was evaluated against the manufacturer's recommended test solvent for rise time, fall time, noise, span drift, zero drift, position sensitivity, battery life, and recharge time. The precision, accuracy, and operating linear range were also determined for the test solvents and some petroleum solvent mixtures which are common refinery products. For these latter mixtures, correction factors are presented which allow for an improved estimate of ambient concentrations when monitoring with each of these instruments. All tests except operating humidity range were performed by challenging each instrument with a known concentration of hydrocarbon generated by evaporating calculated liquid volumes into a static chamber. Humidity tests were performed using a dynamic dilution apparatus generating a fixed concentration of hydrocarbon while relative humidity was varied. Concentrations in both systems were verified by gas injection into gas chromatograph. Each instrument performed well when challenged by manufacturers' recommended test solvents. Humidity was shown to influence each instrument's readings. Also, the instruments were shown to have application as monitors of airborne concentrations of common hydrocarbon solvent mixtures.

  12. EXTRAPOLATION TECHNIQUES EVALUATING 24 HOURS OF AVERAGE ELECTROMAGNETIC FIELD EMITTED BY RADIO BASE STATION INSTALLATIONS: SPECTRUM ANALYZER MEASUREMENTS OF LTE AND UMTS SIGNALS.

    Science.gov (United States)

    Mossetti, Stefano; de Bartolo, Daniela; Veronese, Ivan; Cantone, Marie Claire; Cosenza, Cristina; Nava, Elisa

    2017-04-01

    International and national organizations have formulated guidelines establishing limits for occupational and residential electromagnetic field (EMF) exposure at high-frequency fields. Italian legislation fixed 20 V/m as a limit for public protection from exposure to EMFs in the frequency range 0.1 MHz-3 GHz and 6 V/m as a reference level. Recently, the law was changed and the reference level must now be evaluated as the 24-hour average value, instead of the previous highest 6 minutes in a day. The law refers to a technical guide (CEI 211-7/E published in 2013) for the extrapolation techniques that public authorities have to use when assessing exposure for compliance with limits. In this work, we present measurements carried out with a vectorial spectrum analyzer to identify technical critical aspects in these extrapolation techniques, when applied to UMTS and LTE signals. We focused also on finding a good balance between statistically significant values and logistic managements in control activity, as the signal trend in situ is not known. Measurements were repeated several times over several months and for different mobile companies. The outcome presented in this article allowed us to evaluate the reliability of the extrapolation results obtained and to have a starting point for defining operating procedures. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  13. Extrapolation techniques evaluating 24 hours of average electromagnetic field emitted by radio base station installations: spectrum analyzer measurements of LTE and UMTS signals

    International Nuclear Information System (INIS)

    Mossetti, Stefano; Bartolo, Daniela de; Nava, Elisa; Veronese, Ivan; Cantone, Marie Claire; Cosenza, Cristina

    2017-01-01

    International and national organizations have formulated guidelines establishing limits for occupational and residential electromagnetic field (EMF) exposure at high-frequency fields. Italian legislation fixed 20 V/m as a limit for public protection from exposure to EMFs in the frequency range 0.1 MHz-3 GHz and 6 V/m as a reference level. Recently, the law was changed and the reference level must now be evaluated as the 24-hour average value, instead of the previous highest 6 minutes in a day. The law refers to a technical guide (CEI 211-7/E published in 2013) for the extrapolation techniques that public authorities have to use when assessing exposure for compliance with limits. In this work, we present measurements carried out with a vectorial spectrum analyzer to identify technical critical aspects in these extrapolation techniques, when applied to UMTS and LTE signals. We focused also on finding a good balance between statistically significant values and logistic managements in control activity, as the signal trend in situ is not known. Measurements were repeated several times over several months and for different mobile companies. The outcome presented in this article allowed us to evaluate the reliability of the extrapolation results obtained and to have a starting point for defining operating procedures. (authors)

  14. A methodology which facilitated the evaluation of learning in a mass university course for basic calculus

    Directory of Open Access Journals (Sweden)

    Patricia Villalonga de García

    2005-03-01

    Full Text Available The aim of the present work is to introduce the methodology used to carry out a diagnostic of the system of evaluation in learning for Mathematics I (subject of the first year in the Facultad de Bioquímica, Química y Farmacia of the Universidad Nacional of Tucumán in Argentina This diagnostic was based on a model of alternative evaluation of learning, designed on the basis of criteria resulting from constructivist pedagogical currents and on the basis of methodological principles for the qualitative and quantitative paradigms in socioeducational research. The criteria stated in this model led to the formulation of the hypothesis: “the evaluation of learning in the subject is enhanced with a reductionistic and disintegrated conception of the processes of teaching and learning”. In order to contrast it, surveys were designed which were applied to students in years 2001 and 2003 and to teachers in year 2001, and a study was carried out on the items of summative evaluation of the subject based on the principles of evaluation standards of the National Council of Teachers of Mathematics. The sources of information were chosen by attending to the characteristics of the context of work and the limitations which conditioned the investigation. A technique was designed to analyze the open and close questions of the surveys and to study the items of the exams. This facilitated the elaboration of a system of categories with which the diagnostic was implemented. The methodological design adopted and the sources used were adequate to reach the aims proposed in the study. Besides, they provided the means to find solid argumentations to contrast the hypotheses of work.

  15. Ultrasonographic evaluation of fibroadenoma in the breast: primary signs of mass

    International Nuclear Information System (INIS)

    Yoon, Choon Sik; Kim, Mi Hye; Ahn, Chang Soo; Oh, Ki Keun

    1994-01-01

    To evaluate the ultrasonomammographic findings of breast fibroadenoma. We evaluated the ultrasonographic findings of histopathologically proved 135 fibroadenomas in 103 patients from January 1986 to September 1990, retrospectively. The ultrasonographic examinations were performed with a hand held linear array 5MHz transducer (Acuson 128(USA). Aloka 650, 280(Japan)). Asonopad was also used during the examinations. The common ultrasonographic findings of fibroadenomas usually showed smooth contour in 120 lesions(88.9%), oval or round shape in 114 lesions(84.4%), uniform homogeneous echogenecity in 106 lesions(78.5%), intermediate hypoechoic internal echo pattern in 105 lesions(77.8%), thin boundary echo in 117 lesions(86.7%), lateral shadowings in 97 lesions(72%), and posterior acoustic enhancement in 56 lesions(41%). The longitudinal/transverse ratio of fibroadenoma was revealed between 0.2 and 1.14 (mean 0.58) and usually under 1.0 (68.9%). Finally, most of fibroadenomas are easily diagnosed by ultrasonography but if differential diagnosis from malignant breast mass is difficult due to atypical appearance, other combined modalities such as filmmammography, fine needle aspiration biopsy and MRI are necessary

  16. Ultrasonographic evaluation of fibroadenoma in the breast: primary signs of mass

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Choon Sik; Kim, Mi Hye; Ahn, Chang Soo; Oh, Ki Keun [College of Medicine, Yonsei University, Seoul (Korea, Republic of)

    1994-01-15

    To evaluate the ultrasonomammographic findings of breast fibroadenoma. We evaluated the ultrasonographic findings of histopathologically proved 135 fibroadenomas in 103 patients from January 1986 to September 1990, retrospectively. The ultrasonographic examinations were performed with a hand held linear array 5MHz transducer (Acuson 128(USA). Aloka 650, 280(Japan)). Asonopad was also used during the examinations. The common ultrasonographic findings of fibroadenomas usually showed smooth contour in 120 lesions(88.9%), oval or round shape in 114 lesions(84.4%), uniform homogeneous echogenecity in 106 lesions(78.5%), intermediate hypoechoic internal echo pattern in 105 lesions(77.8%), thin boundary echo in 117 lesions(86.7%), lateral shadowings in 97 lesions(72%), and posterior acoustic enhancement in 56 lesions(41%). The longitudinal/transverse ratio of fibroadenoma was revealed between 0.2 and 1.14 (mean 0.58) and usually under 1.0 (68.9%). Finally, most of fibroadenomas are easily diagnosed by ultrasonography but if differential diagnosis from malignant breast mass is difficult due to atypical appearance, other combined modalities such as filmmammography, fine needle aspiration biopsy and MRI are necessary.

  17. Stability evaluation considering the scattering of the physical properties of rock mass

    International Nuclear Information System (INIS)

    Ito, Hiroshi; Shin, Koichi

    1988-01-01

    The objective of this research is to establish the rational design method which could be evaluated the influence of the scattering of mechanical properties on the stability of the foundation ground of Nuclear Power Plant and surrounding slope. For this purpose, investigation on the actual scattering state of mechanical properties of rock and rock masses, and the stability estimations by the probabilistic method are conducted in this report, and following results are obtained. (1) The actual distribution of scattering of mechanical properties could describe in the probabilistic models of Weibull and Gamma distribution most accurately. The Normal distribution model could also do almostly. The coefficients of variation are so large in the range of 0.4 - 0.8, the remarkable tendency of them among the kinds of mechanical Properties and among the rock classification are not recognized. (2) It is found that the stability estimation considering the scattering of mechanical properties can be sufficiently conducted by using the conventional deterministic method, and the results of deterministic method using the average value of scattering need not be reduce in proportional to the degree of scattering of mechanical properties. (3) Based on these results, new rational design method and procedure, which could be evaluated the scattering of mechanical properties of ground material, is proposed. (author)

  18. Evaluation of laser diode thermal desorption-tandem mass spectrometry (LDTD-MS-MS) in forensic toxicology.

    Science.gov (United States)

    Bynum, Nichole D; Moore, Katherine N; Grabenauer, Megan

    2014-10-01

    Many forensic laboratories experience backlogs due to increased drug-related cases. Laser diode thermal desorption (LDTD) has demonstrated its applicability in other scientific areas by providing data comparable with instrumentation, such as liquid chromatography-tandem mass spectrometry, in less time. LDTD-MS-MS was used to validate 48 compounds in drug-free human urine and blood for screening or quantitative analysis. Carryover, interference, limit of detection, limit of quantitation, matrix effect, linearity, precision and accuracy and stability were evaluated. Quantitative analysis indicated that LDTD-MS-MS produced precise and accurate results with the average overall within-run precision in urine and blood represented by a %CV forensic toxicology but before it can be successfully implemented that there are some challenges that must be addressed. Although the advantages of the LDTD system include minimal maintenance and rapid analysis (∼10 s per sample) which makes it ideal for high-throughput forensic laboratories, a major disadvantage is its inability or difficulty analyzing isomers and isobars due to the lack of chromatography without the use of high-resolution MS; therefore, it would be best implemented as a screening technique. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. [Evaluation of mass spectrometry: MALDI-TOF MS for fast and reliable yeast identification].

    Science.gov (United States)

    Relloso, María S; Nievas, Jimena; Fares Taie, Santiago; Farquharson, Victoria; Mujica, María T; Romano, Vanesa; Zarate, Mariela S; Smayevsky, Jorgelina

    2015-01-01

    The matrix-assisted laser desorption/ionization time-of-flight mass spectrometry technique known as MALDI-TOF MS is a tool used for the identification of clinical pathogens by generating a protein spectrum that is unique for a given species. In this study we assessed the identification of clinical yeast isolates by MALDI-TOF MS in a university hospital from Argentina and compared two procedures for protein extraction: a rapid method and a procedure based on the manufacturer's recommendations. A short protein extraction procedure was applied in 100 isolates and the rate of correct identification at genus and species level was 98.0%. In addition, we analyzed 201 isolates, previously identified by conventional methods, using the methodology recommended by the manufacturer and there was 95.38% coincidence in the identification at species level. MALDI TOF MS showed to be a fast, simple and reliable tool for yeast identification. Copyright © 2014 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. [Evaluation of mass spectrometry for the identification of clinically interesting yeasts].

    Science.gov (United States)

    Galán, Fátima; García-Agudo, Lidia; Guerrero, Inmaculada; Marín, Pilar; García-Tapia, Ana; García-Martos, Pedro; Rodríguez-Iglesias, Manuel

    2015-01-01

    Identification of yeasts is based on morphological, biochemical and nutritional characteristics, and using molecular methods. Matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry, a new method for the identification of microorganisms, has demonstrated to be very useful. The aim of this study is to evaluate this new method in the identification of yeasts. A total of 600 strains of yeasts isolated from clinical specimens belonging to 9 genera and 43 species were tested. Identification was made by sequencing of the ITS regions of ribosomal DNA, assimilation of carbon compounds (ID 32C), and mass spectrometry on a Microflex spectrometer (Bruker Daltonics GmbH, Germany). A total of 569 strains (94.8%) were identified to species level by ID 32C, and 580 (96.7%) by MALDI-TOF. Concordance between both methods was observed for 553 strains (92.2%), with 100% in clinically relevant species: C. albicans, C. glabrata, C. parapsilosis, C. tropicalis, and almost 100% in C. krusei. MALDI-TOF identified species requiring molecular methods: Candida dubliniensis, C. nivariensis, C. metapsilosis and C. orthopsilosis. Some irregularities were observed in the identification of arthroconidia yeast and basidiomycetes. MALDI-TOF is a rapid, effective and economic method, which enables the identification of most clinically important yeasts and the differentiation of closely related species. It would be desirable to include more species in its database to expand its performance. Copyright © 2014 Elsevier España, S.L.U. y Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  1. Evaluation of cochlear function in normal-hearing young adults exposed to MP3 player noise by analyzing transient evoked otoacoustic emissions and distortion products.

    Science.gov (United States)

    Santaolalla Montoya, Francisco; Ibargüen, Agustín Martinez; Vences, Ana Rodriguez; del Rey, Ana Sanchez; Fernandez, Jose Maria Sanchez

    2008-10-01

    Exposure to recreational noise may cause injuries to the inner ear, and transient evoked (TEOAEs) and distortion product otoacoustic emissions (DPOAEs) may identify these cochlear alterations. The goal of this study was to evaluate TEOAEs and DPOAEs as a method to diagnose early cochlear alterations in young adults exposed to MP3 player noise. We performed a prospective study of the cochlear function in normal-hearing MP3 player users by analyzing TEOAE and DPOAE incidence, amplitude, and spectral content. We gathered a sample of 40 ears from patients between 19 and 29 years old (mean age 24.09 years, SD 3.9 years). We compared the results with those of a control group of 232 ears not exposed to MP3 noise from patients aged 18 to 32 years (mean age 23.35 years, SD 2.7 years). Fifty percent of ears were from females and 50% were from males. Subjects who had used MP3 players for most years and for more hours each week exhibited a reduction in TEOAE and DPOAE incidence and amplitudes and an increase in DPOAE thresholds. TEOAEs showed a statistically significant lower incidence and amplitudes for normal-hearing subjects using MP3 players at frequencies of 2000, 3000, and 4000 Hz. DPOAE incidence was lower at 700, 1000, 1500, and 2000 Hz; the amplitudes were lower at frequencies between 1500 and 6000 Hz; and the thresholds were higher for all frequency bands, statistically significant at frequencies from 1500 to 6000 Hz, p MP3 player noise exposure may be detectable by analyzing TEOAEs and DPOAEs before the impairment becomes clinically apparent.

  2. A Lab-On-Chip Phosphate Analyzer for Long-term In Situ Monitoring at Fixed Observatories: Optimization and Performance Evaluation in Estuarine and Oligotrophic Coastal Waters

    Directory of Open Access Journals (Sweden)

    Maxime M. Grand

    2017-08-01

    Full Text Available The development of phosphate sensors suitable for long-term in situ deployments in natural waters, is essential to improve our understanding of the distribution, fluxes, and biogeochemical role of this key nutrient in a changing ocean. Here, we describe the optimization of the molybdenum blue method for in situ work using a lab-on-chip (LOC analyzer and evaluate its performance in the laboratory and at two contrasting field sites. The in situ performance of the LOC sensor is evaluated using hourly time-series data from a 56-day trial in Southampton Water (UK, as well as a month-long deployment in the subtropical oligotrophic waters of Kaneohe Bay (Hawaii, USA. In Kaneohe Bay, where phosphate concentrations were characteristic of the dry season (0.13 ± 0.03 μM, n = 704, the in situ sensor accuracy was 16 ± 12% and a potential diurnal cycle in phosphate concentrations was observed. In Southampton Water, the sensor data (1.02 ± 0.40 μM, n = 1,267 were accurate to ±0.10 μM relative to discrete reference samples. Hourly in situ monitoring revealed striking tidal and storm derived fluctuations in phosphate concentrations in Southampton Water that would not have been captured via discrete sampling. We show the impact of storms on phosphate concentrations in Southampton Water is modulated by the spring-neap tidal cycle and that the 10-fold decline in phosphate concentrations observed during the later stages of the deployment was consistent with the timing of a spring phytoplankton bloom in the English Channel. Under controlled laboratory conditions in a 250 L tank, the sensor demonstrated an accuracy and precision better than 10% irrespective of the salinity (0–30, turbidity (0–100 NTU, colored dissolved organic matter (CDOM concentration (0–10 mg/L, and temperature (5–20°C of the water (0.3–13 μM phosphate being analyzed. This work demonstrates that the LOC technology is mature enough to quantify the influence of stochastic events on

  3. Evaluation of left ventricular mass in vitro and in vivo with MR imaging

    International Nuclear Information System (INIS)

    Mogelvang, J.; Thomsen, C.; Mehisen, J.; Henriksen, O.; Horn, T.

    1986-01-01

    The left ventricular (LV) mass was determined by MR multisection imaging in ten unopened postmortem human hearts and compared with the true weight of the isolated LV. In addition, the LV mass in 14 patients was determined by MR imaging. LV myocardial volume determined from acquisitions at end diastole were compared with the volume determined from acquisitions at end systole. The LV masses as determined on MR imaging showed excellent correlation with reference values (r = .99, P < .001). There was fine correlation between myocardial volume (mass) estimated in vivo in diastole and systole (r = .95, P < .0001). These results suggest that MR imaging is accurate for the determination of LV mass in vivo

  4. Analyzed Using Statistical Moments

    International Nuclear Information System (INIS)

    Oltulu, O.

    2004-01-01

    Diffraction enhanced imaging (DEl) technique is a new x-ray imaging method derived from radiography. The method uses a monorheumetten x-ray beam and introduces an analyzer crystal between an object and a detector Narrow angular acceptance of the analyzer crystal generates an improved contrast over the evaluation radiography. While standart radiography can produce an 'absorption image', DEl produces 'apparent absorption' and 'apparent refraction' images with superior quality. Objects with similar absorption properties may not be distinguished with conventional techniques due to close absorption coefficients. This problem becomes more dominant when an object has scattering properties. A simple approach is introduced to utilize scattered radiation to obtain 'pure absorption' and 'pure refraction' images

  5. Mechanistic model of mass-specific basal metabolic rate: evaluation in healthy young adults.

    Science.gov (United States)

    Wang, Z; Bosy-Westphal, A; Schautz, B; Müller, M

    2011-12-01

    Mass-specific basal metabolic rate (mass-specific BMR), defined as the resting energy expenditure per unit body mass per day, is an important parameter in energy metabolism research. However, a mechanistic explanation for magnitude of mass-specific BMR remains lacking. The objective of the present study was to validate the applicability of a proposed mass-specific BMR model in healthy adults. A mechanistic model was developed at the organ-tissue level, mass-specific BMR = Σ( K i × F i ), where Fi is the fraction of body mass as individual organs and tissues, and K i is the specific resting metabolic rate of major organs and tissues. The Fi values were measured by multiple MRI scans and the K i values were suggested by Elia in 1992. A database of healthy non-elderly non-obese adults (age 20 - 49 yrs, BMI BMR of all subjects was 21.6 ± 1.9 (mean ± SD) and 21.7 ± 1.6 kcal/kg per day, respectively. The measured mass-specific BMR was correlated with the predicted mass-specific BMR (r = 0.82, P BMR, versus the average of measured and predicted mass-specific BMR. In conclusion, the proposed mechanistic model was validated in non-elderly non-obese adults and can help to understand the inherent relationship between mass-specific BMR and body composition.

  6. Clinical application of S-Detect to breast masses on ultrasonography: A study evaluating the diagnostic performance and agreement with a dedicated breast radiologist

    International Nuclear Information System (INIS)

    Kim, Ki Wook; Kim, Eun Kyung; Yoon, Jung Hyun; Song, Mi Kyung

    2017-01-01

    The purpose of this study was to evaluate the diagnostic performance of S-Detect when applied to breast ultrasonography (US), and the agreement with an experienced radiologist specializing in breast imaging. From June to August 2015, 192 breast masses in 175 women were included. US features of the breast masses were retrospectively analyzed by a radiologist who specializes in breast imaging and S-Detect, according to the fourth edition of the American College of Radiology Breast Imaging Reporting and Data System lexicon and final assessment categories. Final assessments from S-Detect were in dichotomized form: possibly benign and possibly malignant. Kappa statistics were used to analyze the agreement between the radiologist and S-Detect. Diagnostic performance of the radiologist and S-Detect was calculated, including sensitivity, specificity, positive predictive value (PPV), negative predictive value, accuracy, and area under the receiving operator characteristics curve. Of the 192 breast masses, 72 (37.5%) were malignant, and 120 (62.5%) were benign. Benign masses among category 4a had higher rates of possibly benign assessment on S-Detect for the radiologist, 63.5% to 36.5%, respectively (P=0.797). When the cutoff was set at category 4a, the specificity, PPV, and accuracy was significantly higher in S-Detect compared to the radiologist (all P<0.05), with a higher area under the receiver operator characteristics curve of 0.725 compared to 0.653 (P=0.038). Moderate agreement (k=0.58) was seen in the final assessment between the radiologist and S-Detect. S-Detect may be used as an additional diagnostic tool to improve the specificity of breast US in clinical practice, and guide in decision making for breast masses detected on US

  7. (Ca,Mg)-Carbonate and Mg-Carbonate at the Phoenix Landing Site: Evaluation of the Phoenix Lander's Thermal Evolved Gas Analyzer (TEGA) Data Using Laboratory Simulations

    Science.gov (United States)

    Sutter, B.; Ming, D. W.; Boynton, W. V.; Niles, P. B.; Morris, R. V.

    2011-01-01

    Calcium carbonate (4.5 wt. %) was detected in the soil at the Phoenix Landing site by the Phoenix Lander s The Thermal and Evolved Gas Analyzer [1]. TEGA operated at 12 mbar pressure, yet the detection of calcium carbonate is based on interpretations derived from thermal analysis literature of carbonates measured under ambient (1000 mbar) and vacuum (10(exp -3) mbar) conditions [2,3] as well as at 100 and 30 mbar [4,5] and one analysis at 12 mbar by the TEGA engineering qualification model (TEGA-EQM). Thermodynamics (Te = H/ S) dictate that pressure affects entropy ( S) which causes the temperature (Te) of mineral decomposition at one pressure to differ from Te obtained at another pressure. Thermal decomposition analyses of Fe-, Mg-, and Ca-bearing carbonates at 12 mbar is required to enhance the understanding of the TEGA results at TEGA operating pressures. The objectives of this work are to (1) evaluate the thermal and evolved gas behavior of a suite of Fe-, Mg-, Ca-carbonate minerals at 1000 and 12 mbar and (2) discuss possible emplacement mechanisms for the Phoenix carbonate.

  8. Impact of reduced-radiation dual-energy protocols using 320-detector row computed tomography for analyzing urinary calculus components: initial in vitro evaluation.

    Science.gov (United States)

    Cai, Xiangran; Zhou, Qingchun; Yu, Juan; Xian, Zhaohui; Feng, Youzhen; Yang, Wencai; Mo, Xukai

    2014-10-01

    To evaluate the impact of reduced-radiation dual-energy (DE) protocols using 320-detector row computed tomography on the differentiation of urinary calculus components. A total of 58 urinary calculi were placed into the same phantom and underwent DE scanning with 320-detector row computed tomography. Each calculus was scanned 4 times with the DE protocols using 135 kV and 80 kV tube voltage and different tube current combinations, including 100 mA and 570 mA (group A), 50 mA and 290 mA (group B), 30 mA and 170 mA (group C), and 10 mA and 60 mA (group D). The acquisition data of all 4 groups were then analyzed by stone DE analysis software, and the results were compared with x-ray diffraction analysis. Noise, contrast-to-noise ratio, and radiation dose were compared. Calculi were correctly identified in 56 of 58 stones (96.6%) using group A and B protocols. However, only 35 stones (60.3%) and 16 stones (27.6%) were correctly diagnosed using group C and D protocols, respectively. Mean noise increased significantly and mean contrast-to-noise ratio decreased significantly from groups A to D (P calculus component analysis while reducing patient radiation exposure to 1.81 mSv. Further reduction of tube currents may compromise diagnostic accuracy. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Unbiased Scanning Method and Data Banking Approach Using Ultra-High Performance Liquid Chromatography Coupled with High-Resolution Mass Spectrometry for Quantitative Comparison of Metabolite Exposure in Plasma across Species Analyzed at Different Dates.

    Science.gov (United States)

    Gao, Hongying; Deng, Shibing; Obach, R Scott

    2015-12-01

    An unbiased scanning methodology using ultra high-performance liquid chromatography coupled with high-resolution mass spectrometry was used to bank data and plasma samples for comparing the data generated at different dates. This method was applied to bank the data generated earlier in animal samples and then to compare the exposure to metabolites in animal versus human for safety assessment. With neither authentic standards nor prior knowledge of the identities and structures of metabolites, full scans for precursor ions and all ion fragments (AIF) were employed with a generic gradient LC method to analyze plasma samples at positive and negative polarity, respectively. In a total of 22 tested drugs and metabolites, 21 analytes were detected using this unbiased scanning method except that naproxen was not detected due to low sensitivity at negative polarity and interference at positive polarity; and 4'- or 5-hydroxy diclofenac was not separated by a generic UPLC method. Statistical analysis of the peak area ratios of the analytes versus the internal standard in five repetitive analyses over approximately 1 year demonstrated that the analysis variation was significantly different from sample instability. The confidence limits for comparing the exposure using peak area ratio of metabolites in animal plasma versus human plasma measured over approximately 1 year apart were comparable to the analysis undertaken side by side on the same days. These statistical analysis results showed it was feasible to compare data generated at different dates with neither authentic standards nor prior knowledge of the analytes.

  10. Cyclodextrin-based miniaturized solid phase extraction for biopesticides analysis in water and vegetable juices samples analyzed by ultra-high-performance liquid chromatography coupled with quadrupole time-of-flight mass spectrometry.

    Science.gov (United States)

    Peng, Li-Qing; Ye, Li-Hong; Cao, Jun; Chang, Yan-Xu; Li, Qin; An, Mingrui; Tan, Zhijing; Xu, Jing-Jing

    2017-07-01

    A cyclodextrin-based miniaturized solid-phase extraction was developed to extract biopesticides from water and vegetable juices. The analytes were detected by ultra-high-performance liquid chromatography coupled with quadrupole time-of-flight tandem mass spectrometry. In the solid-phase extraction (SPE) procedure, the liquid sample solution is passed through a packed column filled with 40mg of HP-β-CD, and then the target analytes are absorbed and finally eluted with methanol-acetic acid (90:10, v/v) into a collection tube. The limits of quantification ranged from 3.73 to 16.51ng/mL for a water matrix, from 2.62 to 13.23ng/mL for an orange juice matrix and from 1.76 to 10.35ng/mL for a tomato juice matrix, respectively. The average recovery values were in the range of 88.3-95.9% for the spiked samples. The established methodology was successfully applied to analyze sanguinarine, berberine, rotenone and osthole in water, orange juice and tomato juice. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Matrix interference evaluation employing GC and LC coupled to triple quadrupole tandem mass spectrometry.

    Science.gov (United States)

    Uclés, S; Lozano, A; Sosa, A; Parrilla Vázquez, P; Valverde, A; Fernández-Alba, A R

    2017-11-01

    Gas and liquid chromatography coupled to triple quadrupole tandem mass spectrometry are currently the most powerful tools employed for the routine analysis of pesticide residues in food control laboratories. However, whatever the multiresidue extraction method, there will be a residual matrix effect making it difficult to identify/quantify some specific compounds in certain cases. Two main effects stand out: (i) co-elution with isobaric matrix interferents, which can be a major drawback for unequivocal identification, and therefore false negative detections, and (ii) signal suppression/enhancement, commonly called the "matrix effect", which may cause serious problems including inaccurate quantitation, low analyte detectability and increased method uncertainty. The aim of this analytical study is to provide a framework for evaluating the maximum expected errors associated with the matrix effects. The worst-case study contrived to give an estimation of the extreme errors caused by matrix effects when extraction/determination protocols are applied in routine multiresidue analysis. Twenty-five different blank matrices extracted with the four most common extraction methods used in routine analysis (citrate QuEChERS with/without PSA clean-up, ethyl acetate and the Dutch mini-Luke "NL" methods) were evaluated by both GC-QqQ-MS/MS and LC-QqQ-MS/MS. The results showed that the presence of matrix compounds with isobaric transitions to target pesticides was higher in GC than under LC in the experimental conditions tested. In a second study, the number of "potential" false negatives was evaluated. For that, ten matrices with higher percentages of natural interfering components were checked. Additionally, the results showed that for more than 90% of the cases, pesticide quantification was not affected by matrix-matched standard calibration when an interferent was kept constant along the calibration curve. The error in quantification depended on the concentration level. In a

  12. Evaluation of Bio-Rad D-100 HbA1c analyzer against Tosoh G8 and Menarini HA-8180V

    Directory of Open Access Journals (Sweden)

    José María Maesa

    2016-08-01

    Full Text Available Objectives: To evaluate the Bio-Rad D-100®, an HPLC analyzer for glycated hemoglobin (HbA1c determination, and to compare its performance with the Menarini HA-8180V® and Sysmex G8®. Methods: Method comparison was performed according to Clinical and Laboratory Standards Institute (CLSI EP9-A2 guidelines. We selected 100 samples from the routine laboratory workload and analyzed them in duplicate with the three analyzers. The imprecision study was performed according to CLSI EP5-A2 guidelines for both inter-assay and intra-assay variability. Bias was assessed with external quality control material. To establish linearity, CLSI EP6-A protocol was followed. Results: Method comparison (95% confidence intervals in parentheses: D-100 vs G8: Passing-Bablok regression; y=0.973(0.963–0.983×−0.07(−0.07−0.069; r=0.9989. Bland-Altman mean difference: −0.229%HbA1c (−0.256: −0.202; Relative bias plot: D-100/G8 vs D100-G8 mean ratio=0.971(0.967−0.975. D-100 vs HA-8180V: Passing-Bablok regression; y=0.944(0.932–0.958×−0.078(0.024−0.173; r=0.9989. Bland-Altman mean difference: −0.363%HbA1c (−0.401: −0.325; Relative bias plot D-100/HA-8180V vs D100-HA-8180V mean ratio=0.955(0.952−0.958. Inter-assay coefficient of variation (CV: 0.81%. Intra-assay CV: 1.04% (low level, and 0.78% (high level. Bias against target value=2.332%. Linearity: r2=0.998 in the concentration range 4.4−13.9%HbA1c. Carry-over: 0.0024%. Conclusions: The Bio-Rad D-100 shows good correlation with G8 and HA-8180V. There is a small proportional systematic difference (2.7% and 5.6%, respectively in both comparisons. Inter and intra-assay CVs are both lower than the lowest CV obtained in studies performed with D-100 and other instruments. Keywords: Glycated hemoglobin, High performance liquid chromatography, Analyzer, Intra-assay variability, Inter-assay variability

  13. Transmission assessment surveys (TAS to define endpoints for lymphatic filariasis mass drug administration: a multicenter evaluation.

    Directory of Open Access Journals (Sweden)

    Brian K Chu

    Full Text Available BACKGROUND: Lymphatic filariasis (LF is targeted for global elimination through treatment of entire at-risk populations with repeated annual mass drug administration (MDA. Essential for program success is defining and confirming the appropriate endpoint for MDA when transmission is presumed to have reached a level low enough that it cannot be sustained even in the absence of drug intervention. Guidelines advanced by WHO call for a transmission assessment survey (TAS to determine if MDA can be stopped within an LF evaluation unit (EU after at least five effective rounds of annual treatment. To test the value and practicality of these guidelines, a multicenter operational research trial was undertaken in 11 countries covering various geographic and epidemiological settings. METHODOLOGY: The TAS was conducted twice in each EU with TAS-1 and TAS-2 approximately 24 months apart. Lot quality assurance sampling (LQAS formed the basis of the TAS survey design but specific EU characteristics defined the survey site (school or community, eligible population (6-7 year olds or 1(st-2(nd graders, survey type (systematic or cluster-sampling, target sample size, and critical cutoff (a statistically powered threshold below which transmission is expected to be no longer sustainable. The primary diagnostic tools were the immunochromatographic (ICT test for W. bancrofti EUs and the BmR1 test (Brugia Rapid or PanLF for Brugia spp. EUs. PRINCIPAL FINDINGS/CONCLUSIONS: In 10 of 11 EUs, the number of TAS-1 positive cases was below the critical cutoff, indicating that MDA could be stopped. The same results were found in the follow-up TAS-2, therefore, confirming the previous decision outcome. Sample sizes were highly sex and age-representative and closely matched the target value after factoring in estimates of non-participation. The TAS was determined to be a practical and effective evaluation tool for stopping MDA although its validity for longer-term post

  14. Transmission assessment surveys (TAS) to define endpoints for lymphatic filariasis mass drug administration: a multicenter evaluation.

    Science.gov (United States)

    Chu, Brian K; Deming, Michael; Biritwum, Nana-Kwadwo; Bougma, Windtaré R; Dorkenoo, Améyo M; El-Setouhy, Maged; Fischer, Peter U; Gass, Katherine; Gonzalez de Peña, Manuel; Mercado-Hernandez, Leda; Kyelem, Dominique; Lammie, Patrick J; Flueckiger, Rebecca M; Mwingira, Upendo J; Noordin, Rahmah; Offei Owusu, Irene; Ottesen, Eric A; Pavluck, Alexandre; Pilotte, Nils; Rao, Ramakrishna U; Samarasekera, Dilhani; Schmaedick, Mark A; Settinayake, Sunil; Simonsen, Paul E; Supali, Taniawati; Taleo, Fasihah; Torres, Melissa; Weil, Gary J; Won, Kimberly Y

    2013-01-01

    Lymphatic filariasis (LF) is targeted for global elimination through treatment of entire at-risk populations with repeated annual mass drug administration (MDA). Essential for program success is defining and confirming the appropriate endpoint for MDA when transmission is presumed to have reached a level low enough that it cannot be sustained even in the absence of drug intervention. Guidelines advanced by WHO call for a transmission assessment survey (TAS) to determine if MDA can be stopped within an LF evaluation unit (EU) after at least five effective rounds of annual treatment. To test the value and practicality of these guidelines, a multicenter operational research trial was undertaken in 11 countries covering various geographic and epidemiological settings. The TAS was conducted twice in each EU with TAS-1 and TAS-2 approximately 24 months apart. Lot quality assurance sampling (LQAS) formed the basis of the TAS survey design but specific EU characteristics defined the survey site (school or community), eligible population (6-7 year olds or 1(st)-2(nd) graders), survey type (systematic or cluster-sampling), target sample size, and critical cutoff (a statistically powered threshold below which transmission is expected to be no longer sustainable). The primary diagnostic tools were the immunochromatographic (ICT) test for W. bancrofti EUs and the BmR1 test (Brugia Rapid or PanLF) for Brugia spp. EUs. In 10 of 11 EUs, the number of TAS-1 positive cases was below the critical cutoff, indicating that MDA could be stopped. The same results were found in the follow-up TAS-2, therefore, confirming the previous decision outcome. Sample sizes were highly sex and age-representative and closely matched the target value after factoring in estimates of non-participation. The TAS was determined to be a practical and effective evaluation tool for stopping MDA although its validity for longer-term post-MDA surveillance requires further investigation.

  15. 201Tl scintigraphic evaluation of tumor mass and viability of bone and soft-tissue tumors

    International Nuclear Information System (INIS)

    Tsuda, Takatoshi; Kubota, Masahiro; Yoshida, Satoru; Shibata, Masahito; Wakabayashi, Jun-ichi; Obata, Hiroyuki; Matsuyama, Toshikatsu; Usui, Masamichi; Ishii, Sei-ichi.

    1994-01-01

    To characterize 201 Tl uptake in patients with bone and soft-tissue tumor, we studied 49 patients with surgically proven tumors and one patient with a tumor diagnosed arteriographically. In 37 of our 50 patients, the tumor was evaluated with 201 Tl and arteriography. Moreover, in 14 of patients with pre-operative chemotherapy, pathologic changes were graded on the basis of percent tumor necrosis as defined histologically. The percent tumor necrosis histologically was compared with changes in the scintigraphic and conventional angiographic studies. Radiologic comparisons demonstrated a high degree of correlation with images of 201 Tl and both arterial and blood pool phase of 99m Tc-HMDP. Ninety-six percent of 28 malignant tumors had positive 201 Tl uptake. None of the patients showed any thallium accumulation in the soft tissues or skeleton adjacent to the lesion. Activity of 201 Tl was mainly dependent upon a tumor blood flow and a vascular density. In of 14 cases with the preoperative chemotherapeutic treatment, 201 Tl scintigraphic changes showed concordance with % tumor necrosis. Thallium-201 was superior to 99m Tc-HMDP in predicting tumor response to chemotherapy. Interestingly, delayed images of 99m Tc-HMDP of 5 responders with >90% tumor necrosis showed decreased uptake in the adjacent bone to the tumor mass lesions. It seems to be quite all right to consider that a major determinant of 201 Tl uptake is intratumoral angiogenecity, which is closely connected with tumor viability. Therefore, 201 Tl is a sensitive radiopharmaceutical for detection of vascular rich bone and soft-tissue tumors, and appears to be a simple and an accurate test for evaluating the response to specific therapeutic regimens of malignant bone and soft-tissue tumors. (author)

  16. Evaluation of the relationship between age, gender, and body mass index, and lumbar facet joint pain

    Directory of Open Access Journals (Sweden)

    Arman Taheri

    2016-01-01

    Full Text Available Introduction: Lumbar facet joint pain accounts for 5-15% of the cases of chronic, axial low back pain. Most commonly, facetogenic pain is the result of repetitive stress and/or cumulative low level trauma, leading to inflammation and stretching of the joint capsule. Patients and Methods: In this descriptive study 76 patients who were diagnosed, after a diagnostic block, as having lumbar facet joint pain were evaluated by their age, sex, and body mass index (BMI. Data were collected according to a checklist and entered to SPSS version 16. Results: The mean age of the participants was 48.53 years; the participants included 44 women and 32 men. Lumbar facet joint pain was more frequent in the age range of 40-55 years. With respect to BMI, lumbar facet joint pain was most frequently seen in patients with BMI of 24.5-29.5 kg/m 2 (40.8%. Conclusion: Based on our findings, the chances of developing lumbar facet joint pain is more in women who are between 40 years and 55 years of age and whose BMI is 24.5-29.5 kg/m 2 .

  17. The Frasnian-Famennian mass killing event(s), methods of identification and evaluation

    Science.gov (United States)

    Geldsetzer, H. H. J.

    1988-01-01

    The absence of an abnormally high number of earlier Devonian taxa from Famennian sediments was repeatedly documented and can hardly be questioned. Primary recognition of the event(s) was based on paleontological data, especially common macrofossils. Most paleontologists place the disappearance of these common forms at the gigas/triangularis contact and this boundary was recently proposed as the Frasnian-Famennian (F-F) boundary. Not unexpectedly, alternate F-F positions were suggested caused by temporary Frasnian survivors or sudden post-event radiations of new forms. Secondary supporting evidence for mass killing event(s) is supplied by trace element and stable isotope geochemistry but not with the same success as for the K/T boundary, probably due to additional 300 ma of tectonic and diagenetic overprinting. Another tool is microfacies analysis which is surprisingly rarely used even though it can explain geochemical anomalies or paleontological overlap not detectable by conventional macrofacies analysis. The combination of microfacies analysis and geochemistry was applied at two F-F sections in western Canada and showed how interdependent the two methods are. Additional F-F sections from western Canada, western United States, France, Germany and Australia were sampled or re-sampled and await geochemical/microfacies evaluation.

  18. Prolegomena to any future computer evaluation of the QCD mass spectrum

    International Nuclear Information System (INIS)

    Parisi, G.

    1984-01-01

    In recent years we have seen many computer based evaluations of the QCD mass spectrum. At the present moment a reliable control of the systematic errors is not yet achieved; as far as the main sources of systematic errors are the non zero values of the lattice spacing and the finite size of the box, in which the hadrons are confined, we need to do extensive computations on lattices of different shapes in order to be able to extrapolate to zero lattice spacing and to infinite box. While it is necessary to go to larger lattices, we also need efficient algorithms in order to minimize the statistical and systematic errors and to decrease the CPU time (and the memory) used in the computation. In these lectures the reader will find a review of the most common algorithms (with the exclusion of the application to gauge theories of the hopping parameter expansion in the form proposed: it can be found in Montvay's contribution to this school); the weak points of the various algorithms are discussed and, when possible, the way to improve them is suggested. For reader convenience the basic formulae are recalled in the second section; in section three we find a discussion of finite volume effects, while the effects of a finite lattice spacing are discussed in section four; some techniques for fighting against the statistical errors and the critical slowing down are found in section five and six respectively. Finally the conclusions are in section seven

  19. Evaluation of 14C abundance in soil respiration using accelerator mass spectrometry

    International Nuclear Information System (INIS)

    Koarashi, Jun; Iida, Takao; Moriizumi, Jun; Asano, Tomohiro

    2004-01-01

    To clarify the behavior of 14 C in terrestrial ecosystems, 14 C abundance in soil respiration was evaluated in an urban forest with a new method involving a closed chamber technique and 14 C measurement by accelerator mass spectrometry (AMS). Soil respiration had a higher Δ 14 C than the contemporary atmosphere. This indicates that a significant portion of soil respiration is derived from the decomposition of soil organic matter enriched in 14 C by atmospheric nuclear weapons tests, with a notable time lag between atmospheric 14 C addition and re-emission from soil. On the other hand, δ 14 C in soil respiration demonstrated that 14 C abundance ratio itself in soil-respired CO 2 is not always high compared with that in atmospheric CO 2 because of the isotope fractionation during plant photosynthesis and microbial decomposition of soil organic matter. The Δ 14 C in soil respiration was slightly lower in August than in March, suggesting a relatively high contribution of plant root respiration and decomposition of newly accumulated and/or 14 C-depleted soil organic matter to the total soil respiration in August

  20. Evaluation of PCR electrospray-ionization mass spectrometry for rapid molecular diagnosis of bovine mastitis.

    Science.gov (United States)

    Perreten, Vincent; Endimiani, Andrea; Thomann, Andreas; Wipf, Juliette R K; Rossano, Alexandra; Bodmer, Michèle; Raemy, Andreas; Sannes-Lowery, Kristin A; Ecker, David J; Sampath, Rangarajan; Bonomo, Robert A; Washington, Cicely

    2013-06-01

    Bovine mastitis, an inflammatory disease of the mammary gland, is one of the most costly diseases affecting the dairy industry. The treatment and prevention of this disease is linked heavily to the use of antibiotics in agriculture and early detection of the primary pathogen is essential to control the disease. Milk samples (n=67) from cows suffering from mastitis were analyzed for the presence of pathogens using PCR electrospray-ionization mass spectrometry (PCR/ESI-MS) and were compared with standard culture diagnostic methods. Concurrent identification of the primary mastitis pathogens was obtained for 64% of the tested milk samples, whereas divergent results were obtained for 27% of the samples. The PCR/ESI-MS failed to identify some of the primary pathogens in 18% of the samples, but identified other pathogens as well as microorganisms in samples that were negative by culture. The PCR/ESI-MS identified bacteria to the species level as well as yeasts and molds in samples that contained a mixed bacterial culture (9%). The sensitivity of the PCR/ESI-MS for the most common pathogens ranged from 57.1 to 100% and the specificity ranged from 69.8 to 100% using culture as gold standard. The PCR/ESI-MS also revealed the presence of the methicillin-resistant gene mecA in 16.2% of the milk samples, which correlated with the simultaneous detection of staphylococci including Staphylococcus aureus. We demonstrated that PCR/ESI-MS, a more rapid diagnostic platform compared with bacterial culture, has the significant potential to serve as an important screening method in the diagnosis of bovine clinical mastitis and has the capacity to be used in infection control programs for both subclinical and clinical disease. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  1. ASDA - Advanced Suit Design Analyzer computer program

    Science.gov (United States)

    Bue, Grant C.; Conger, Bruce C.; Iovine, John V.; Chang, Chi-Min

    1992-01-01

    An ASDA model developed to evaluate the heat and mass transfer characteristics of advanced pressurized suit design concepts for low pressure or vacuum planetary applications is presented. The model is based on a generalized 3-layer suit that uses the Systems Integrated Numerical Differencing Analyzer '85 in conjunction with a 41-node FORTRAN routine. The latter simulates the transient heat transfer and respiratory processes of a human body in a suited environment. The user options for the suit encompass a liquid cooled garment, a removable jacket, a CO2/H2O permeable layer, and a phase change layer.

  2. High-precision measurement of phenylalanine δ15N values for environmental samples: a new approach coupling high-pressure liquid chromatography purification and elemental analyzer isotope ratio mass spectrometry.

    Science.gov (United States)

    Broek, Taylor A B; Walker, Brett D; Andreasen, Dyke H; McCarthy, Matthew D

    2013-11-15

    Compound-specific isotope analysis of individual amino acids (CSI-AA) is a powerful new tool for tracing nitrogen (N) source and transformation in biogeochemical cycles. Specifically, the δ(15)N value of phenylalanine (δ(15)N(Phe)) represents an increasingly used proxy for source δ(15)N signatures, with particular promise for paleoceanographic applications. However, current derivatization/gas chromatography methods require expensive and relatively uncommon instrumentation, and have relatively low precision, making many potential applications impractical. A new offline approach has been developed for high-precision δ(15)N measurements of amino acids (δ(15)N(AA)), optimized for δ(15)N(Phe) values. Amino acids (AAs) are first purified via high-pressure liquid chromatography (HPLC), using a mixed-phase column and automated fraction collection. The δ(15)N values are determined via offline elemental analyzer-isotope ratio mass spectrometry (EA-IRMS). The combined HPLC/EA-IRMS method separated most protein AAs with sufficient resolution to obtain accurate δ(15)N values, despite significant intra-peak isotopic fractionation. For δ(15)N(Phe) values, the precision was ±0.16‰ for standards, 4× better than gas chromatography/combustion/isotope ratio mass spectrometry (GC/C/IRMS; ±0.64‰). We also compared a δ(15)N(Phe) paleo-record from a deep-sea bamboo coral from Monterey Bay, CA, USA, using our method versus GC/C/IRMS. The two methods produced equivalent δ(15)N(Phe) values within error; however, the δ(15)N(Phe) values from HPLC/EA-IRMS had approximately twice the precision of GC/C/IRMS (average stdev of 0.27‰ ± 0.14‰ vs 0.60‰ ± 0.20‰, respectively). These results demonstrate that offline HPLC represents a viable alternative to traditional GC/C/IMRS for δ(15)N(AA) measurement. HPLC/EA-IRMS is more precise and widely available, and therefore useful in applications requiring increased precision for data interpretation (e.g. δ(15)N paleoproxies

  3. Evaluation and optimization of high-performance liquid chromatography coupled with high-resolution mass spectrometry for phospholipid quantitation.

    Science.gov (United States)

    Fu, Mingkun; Xu, Wei; Lu, Qing; Pan, Guoyu; Varga, Csanad

    2014-04-15

    High-performance liquid chromatography coupled with high-resolution mass spectrometry (HPLC/HRMS) provides an attractive alternative to the traditional triple quadrupole mass spectrometry selected reaction monitoring (SRM) methodology in the field of quantitation. An LTQ Orbitrap Velos mass spectrometer coupled with a Shimadzu UHPLC system was used. A mass extraction window (MEW) was defined to mathematically correlate with mass resolving power (MRP). Five MRP measurement conditions at 7500, 15,000, 30,000, 60,000, and 100,000, and five MEW widths at 10%, 20%, 50%, and 100% of ±1000000/MRP, and were utilized as the experimental conditions. Comparison of profile and centroid algorithms was evaluated as well. Selection of pH 8.5 buffer, C4 column, 20% IPA, and 10 ppm H3 PO4 , minimized hydrophobic and silanol interactions to enhance separation. Narrowing the MEW minimized background noise, while over-narrowing the MEW gave signal loss due to mass accuracy deviation. The mass accuracy deviation was larger for lower MRP measurements especially with centriod data, and hence a profile algorithm was recommended. The post-ionization signal suppression was observed with low MRP and was further confirmed with the analysis of multi-level linearity. It was found that the HPLC/HRMS method with conditions of 20% ±1000000/MRP as MEW, 30,000 or 60,000 MRP, and profile algorithm, provide optimum results for quantitation of seven model phospholipids. Copyright © 2014 John Wiley & Sons, Ltd.

  4. Evaluation of lead isotope compositions of NIST NBS 981 measured by thermal ionization mass spectrometer and multiple-collector inductively coupled plasma mass spectrometer

    Directory of Open Access Journals (Sweden)

    Honglin Yuan

    2016-09-01

    Full Text Available Because Pb isotopes can be used for tracing, they are widely used in many disciplines. The detection and analysis of Pb isotopes of bulk samples are usually conducted using thermal ionization mass spectrometer (TIMS and multiple-collector inductively coupled plasma mass spectrometer (MC-ICP-MS, both of which need external reference materials with known isotopic compositions to correct for the mass discrimination effect produced during analysis. NIST NBS 981 is the most widely used reference material for Pb isotope analysis; however, the isotopic compositions reported by various analytical laboratories, especially those using TIMS, vary from each other. In this study, we statistically evaluated 229 reported TIMS analysis values collected by GeoReM in the last 30 years, 176 reported MC-ICP-MS analysis values, and 938 MC-ICP-MS analysis results from our laboratory in the last five years. After careful investigation, only 40 TIMS results were found to have double or triple spikes. The ratios of the overall weighted averages, 206Pb/204Pb, 207Pb/204Pb, and 208Pb/204Pb, obtained from 40 spiked TIMS reports and 1114 MC-ICP-MS results of NIST NBS 981 isotopes were 16.9406 ± 0.0003 (2s, 15.4957 ± 0.0002 (2s, and 36.7184 ± 0.0007 (2s, respectively.

  5. Diagnostic performance of quantitative shear wave elastography in the evaluation of solid breast masses: determination of the most discriminatory parameter.

    Science.gov (United States)

    Au, Frederick Wing-Fai; Ghai, Sandeep; Moshonov, Hadas; Kahn, Harriette; Brennan, Cressida; Dua, Hemi; Crystal, Pavel

    2014-09-01

    The purpose of this article is to assess the diagnostic performance of quantitative shear wave elastography in the evaluation of solid breast masses and to determine the most discriminatory parameter. B-mode ultrasound and shear wave elastography were performed before core biopsy of 123 masses in 112 women. The diagnostic performance of ultrasound and quantitative shear wave elastography parameters (mean elasticity, maximum elasticity, and elasticity ratio) were compared. The added effect of shear wave elastography on the performance of ultrasound was determined. The mean elasticity, maximum elasticity, and elasticity ratio were 24.8 kPa, 30.3 kPa, and 1.90, respectively, for 79 benign masses and 130.7 kPa, 154.9 kPa, and 11.52, respectively, for 44 malignant masses (p shear wave elastography parameter was higher than that of ultrasound (p shear wave elastography parameters to the evaluation of BI-RADS category 4a masses, about 90% of masses could be downgraded to BI-RADS category 3. The numbers of downgraded masses were 40 of 44 (91%) for mean elasticity, 39 of 44 (89%) for maximum elasticity, and 42 of 44 (95%) for elasticity ratio. The numbers of correctly downgraded masses were 39 of 40 (98%) for mean elasticity, 38 of 39 (97%) for maximum elasticity, and 41 of 42 (98%) for elasticity ratio. There was improvement in the diagnostic performance of ultrasound of mass assessment with shear wave elastography parameters added to BI-RADS category 4a masses compared with ultrasound alone. Combined ultrasound and elasticity ratio had the highest improvement, from 35.44% to 87.34% for specificity, from 45.74% to 80.77% for positive predictive value, and from 57.72% to 90.24% for accuracy (p shear wave elastography parameters of benign and malignant solid breast masses. By adding shear wave elastography parameters to BI-RADS category 4a masses, we found that about 90% of them could be correctly downgraded to BI-RADS category 3, thereby avoiding biopsy. Elasticity ratio

  6. Evaluation of aerosol composition changes in the last 60 years around southeastern Greenland by analyzing micro-inclusions in the SE-Dome ice core using Raman spectroscopy.

    Science.gov (United States)

    Ando, T.; Iizuka, Y.; Ohno, H.; Sugiyama, S.

    2017-12-01

    Emission regulation of anthropogenic NOX and SOX since late 90's rather caused excess atmospheric ammonium (NH3) in agricultural regions (Warner et al., 2017, Geophys. Res. Lett.). The Arctic is one of the most sensitive areas for future warming. Aerosols in the Arctic are transported from the Northern Hemisphere and mostly experience wet deposition (Breider et al., 2014, Jour. of Geophys. Res.: Atmos.). Ice cores preserve past water-soluble aerosols. From these viewpoints, ice cores from the Arctic is suitable to evaluate recent variation in aerosol composition due to human activity in the Northern Hemisphere and aerosol transportation. We analyzed ion concentrations in the ice core samples from a southeastern dome in Greenland (SE-Dome). The concentrations increased for NH4+ and decreased for SO42- after late 90's. The NH4+ increasing trend is due to excess NH3 emission in North America. Cloud nuclei formation depends on chemical form of aerosols. Thus, differences in chemical forms of these ammonium aerosols in SE-Dome samples are important to evaluate the effect on climate change in Greenland. In this study, we identified the chemical form of aerosols (water-soluble inclusions) in the SE-Dome ice core by using micro-Raman spectroscopy. SE-Dome ice core samples were collected in 2015 and enabled us to reconstruct seasonal variation owing to extremely higher accumulation rate ( 1m/yr.). The ice samples were sublimated and accumulated inclusions on the Ni sheets in a clean booth under -22 degrees Celsius. We identified CaSO4, Na2SO4, (NH4)2SO4, NaNO3, NH4NO3 by Raman spectra. This is the first report to identify ammonium salts ((NH4)2SO4 and NH4NO3) from ice core sample. In the summer samples, the relative abundances of CaSO4 and NaNO3 are lower but (NH4)2SO4 are higher than those in the spring samples. NH4+ rapidly react with SO24- under higher temperature. Higher concentration of NH3 in the warmest season possibly enhanced the formation of (NH4)2SO4 in North

  7. Methods of analyzing crude oil

    Science.gov (United States)

    Cooks, Robert Graham; Jjunju, Fred Paul Mark; Li, Anyin; Rogan, Iman S.

    2017-08-15

    The invention generally relates to methods of analyzing crude oil. In certain embodiments, methods of the invention involve obtaining a crude oil sample, and subjecting the crude oil sample to mass spectrometry analysis. In certain embodiments, the method is performed without any sample pre-purification steps.

  8. Mass Customization of Teaching and Training in Organizations: Design Principles and Prototype Evaluation

    Science.gov (United States)

    Nistor, Nicolae; Dehne, Anina; Drews, Frank Thomas

    2010-01-01

    In search of methods that improve the efficiency of teaching and training in organizations, several authors point out that mass customization (MC) is a principle that covers individual needs of knowledge and skills and, at the same time limits the development costs of customized training to those of mass training. MC is proven and established in…

  9. Comparative evaluation of left ventricular mass regression after aortic valve replacement: a prospective randomized analysis

    Directory of Open Access Journals (Sweden)

    Kiessling Arndt H

    2011-10-01

    Full Text Available Abstract Background We assessed the hemodynamic performance of various prostheses and the clinical outcomes after aortic valve replacement, in different age groups. Methods One-hundred-and-twenty patients with isolated aortic valve stenosis were included in this prospective randomized randomised trial and allocated in three age-groups to receive either pulmonary autograft (PA, n = 20 or mechanical prosthesis (MP, Edwards Mira n = 20 in group 1 (age 75. Clinical outcomes and hemodynamic performance were evaluated at discharge, six months and one year. Results In group 1, patients with PA had significantly lower mean gradients than the MP (2.6 vs. 10.9 mmHg, p = 0.0005 with comparable left ventricular mass regression (LVMR. Morbidity included 1 stroke in the PA population and 1 gastrointestinal bleeding in the MP subgroup. In group 2, mean gradients did not differ significantly between both populations (7.0 vs. 8.9 mmHg, p = 0.81. The rate of LVMR and EF were comparable at 12 months; each group with one mortality. Morbidity included 1 stroke and 1 gastrointestinal bleeding in the stentless and 3 bleeding complications in the MP group. In group 3, mean gradients did not differ significantly (7.8 vs 6.5 mmHg, p = 0.06. Postoperative EF and LVMR were comparable. There were 3 deaths in the stented group and no mortality in the stentless group. Morbidity included 1 endocarditis and 1 stroke in the stentless compared to 1 endocarditis, 1 stroke and one pulmonary embolism in the stented group. Conclusions Clinical outcomes justify valve replacement with either valve substitute in the respective age groups. The PA hemodynamically outperformed the MPs. Stentless valves however, did not demonstrate significantly superior hemodynamics or outcomes in comparison to stented bioprosthesis or MPs.

  10. Evaluation of the relationship and genetic overlap between Kashin-Beck disease and body mass index.

    Science.gov (United States)

    Wen, Y; Hao, J; Xiao, X; Guo, X; Wang, W; Yang, T; Shen, H; Tian, Q; Tan, L; Deng, H-W; Zhang, F

    2016-11-01

    Body mass index (BMI) is one of the major factors affecting the development of osteoarthritis (OA) but there is currently no information available regarding the relationship between BMI and Kashin-Beck disease (KBD). Our aim in this study was to investigate the relationship and genetic overlap between BMI and KBD. A total of 2050 Han Chinese subjects participated in this study. Using a cohort of 333 grade I KBD patients, logistic regression analysis was conducted to evaluate the correlation between BMI and KBD. Another independent sample of 1717 subjects was genotyped for a genome-wide association study (GWAS) using Affymetrix Human SNP 6.0 Arrays. Single nucleotide polymorphism (SNP) effect concordance analysis (SECA) was applied to the GWAS summaries of KBD and BMI for pleiotropy analysis. Genome-wide bivariate association analysis (GWBAA) of KBD and BMI was carried out to identify the genes with pleiotropic effects on KBD and BMI. The relevance of identified genes with KBD was validated by gene expression profiling and immunohistochemistry. BMI correlated positively with knee movement disorder in KBD (coefficient β = 0.068, p = 0.045). SECA identified a significant pleiotropic effect (empirical p = 0.021) between KBD and BMI. In the GWBAA, the rs1893577 of the ADAMTS1 gene achieved the most significant association signal (p = 7.38 × 10 -9 ). ADAMTS1 was also up-regulated in KBD vs. normal (ratio = 2.64 ± 2.80) and KBD vs. OA (ratio = 2.31 ± 2.01). The rate of ADAMTS1-positive chondrocytes in KBD was significantly higher than that in OA (p < 0.05) and healthy controls (p < 0.05). Our results suggest that ADAMTS1 is a novel susceptibility gene for KBD.

  11. Easy Extraction Method To Evaluate δ13C Vanillin by Liquid Chromatography-Isotopic Ratio Mass Spectrometry in Chocolate Bars and Chocolate Snack Foods.

    Science.gov (United States)

    Bononi, Monica; Quaglia, Giancarlo; Tateo, Fernando

    2015-05-20

    An easy extraction method that permits the use of a liquid chromatography-isotopic ratio mass spectrometry (LC-IRMS) system to evaluate δ(13)C of vanillin in chocolate products and industrial flavorings is presented. The method applies the determination of stable isotopes of carbon to discriminate between natural vanillin from vanilla beans and vanillin from other sources (mixtures from beans, synthesis, or biotechnology). A series of 13 chocolate bars and chocolate snack foods available on the Italian market and 8 vanilla flavorings derived from industrial quality control processes were analyzed. Only 30% of products considered in this work that declared "vanilla" on the label showed data that permitted the declaration "vanilla" according to European Union (EU) Regulation 1334/2008. All samples not citing "vanilla" or "natural flavoring" on the label gave the correct declaration. The extraction method is presented with data useful for statistical evaluation.

  12. Climate Model Diagnostic Analyzer

    Science.gov (United States)

    Lee, Seungwon; Pan, Lei; Zhai, Chengxing; Tang, Benyang; Kubar, Terry; Zhang, Zia; Wang, Wei

    2015-01-01

    The comprehensive and innovative evaluation of climate models with newly available global observations is critically needed for the improvement of climate model current-state representation and future-state predictability. A climate model diagnostic evaluation process requires physics-based multi-variable analyses that typically involve large-volume and heterogeneous datasets, making them both computation- and data-intensive. With an exploratory nature of climate data analyses and an explosive growth of datasets and service tools, scientists are struggling to keep track of their datasets, tools, and execution/study history, let alone sharing them with others. In response, we have developed a cloud-enabled, provenance-supported, web-service system called Climate Model Diagnostic Analyzer (CMDA). CMDA enables the physics-based, multivariable model performance evaluations and diagnoses through the comprehensive and synergistic use of multiple observational data, reanalysis data, and model outputs. At the same time, CMDA provides a crowd-sourcing space where scientists can organize their work efficiently and share their work with others. CMDA is empowered by many current state-of-the-art software packages in web service, provenance, and semantic search.

  13. Evaluation of the national tobacco control mass media campaign in China

    Directory of Open Access Journals (Sweden)

    Xuezheng Jin

    2018-03-01

    The mass media campaign reinforced people's knowledge and attitudes about harmful health effects of smoking and SHS exposure, increased people's desire to quit, and improved people's support for smoking bans in public places.

  14. A clinical study evaluating bone mineral mass in the radius during skeletal growth

    International Nuclear Information System (INIS)

    Hagino, Hiroshi

    1989-01-01

    Using 125-I single photon absorptiometry, bone mineral measurements were performed on 206 healthy Japanese children (2 to 19 years of age). Bone mineral content (BMC), bone width (BW) and BMC/BW values were determined for the radius at distal 1/6 site (metaphysis) and distal 1/3 site (diaphysis). BMC/BW values at both sites correlated well with body height and weight. Bone mass in the diaphysis (distal 1/3 site) increased linearly during the 2-19 years of skeletal growth, but bone mass in the metaphysis (1/6 site) increased steeply during the pubertal period. In children receiving glucocorticoid therapy, bone mass was reduced in proportion to the duration of drug administration. In children under anticonvulsant therapy, the yearly increse in bone mass was significantly low especially in those patients with poor physical activity levels. Bone mineral decrease in the radius occurred in the children with hypopituitalism, hypothyroidism (cretinism), hyperthyroidism and Turner's syndrome. (author)

  15. Evaluation of precision in measurements of uranium isotope ratio by thermionic mass spectrometry

    International Nuclear Information System (INIS)

    Moraes, N.M.P. de; Rodrigues, C.

    1977-01-01

    The parameters which affect the precision and accuracy of uranium isotopic ratios measurements by thermionic mass spectrometry are discussed. A statistical designed program for the analysis of the internal and external variances are presented. It was done an application of this statistical methods, in order to get mass discrimination factor, and its standard mean deviation, by using some results already published for 235 U/ 238 U ratio in NBS uranium samples, and natural uranium [pt

  16. Children's self-perceived bodily competencies and associations with motor skills, body mass index, teachers' evaluations, and parents' concerns

    DEFF Research Database (Denmark)

    Toftegaard-Stoeckel, Jan; Groenfeldt, Vivian; Andersen, Lars Bo

    2010-01-01

    The associations between physical competence, self-perceived bodily competence, parental concern for their children's motor skill development, and teachers' evaluation of their bodily competence were assessed in 646 six- to seven-year-olds. Physical competence was assessed by the German motor...... ability test "Korperkoordinationstest fur Kinder", while the children's, their parents', and their teachers' evaluations were obtained through questionnaires. Parental concern, teacher evaluation, and a high body mass index were the strongest predictors of low physical competence (motor skill quotient ...

  17. A Pivotal Study of Optoacoustic Imaging to Diagnose Benign and Malignant Breast Masses: A New Evaluation Tool for Radiologists.

    Science.gov (United States)

    Neuschler, Erin I; Butler, Reni; Young, Catherine A; Barke, Lora D; Bertrand, Margaret L; Böhm-Vélez, Marcela; Destounis, Stamatia; Donlan, Pamela; Grobmyer, Stephen R; Katzen, Janine; Kist, Kenneth A; Lavin, Philip T; Makariou, Erini V; Parris, Tchaiko M; Schilling, Kathy J; Tucker, F Lee; Dogan, Basak E

    2018-05-01

    Purpose To compare the diagnostic utility of an investigational optoacoustic imaging device that fuses laser optical imaging (OA) with grayscale ultrasonography (US) to grayscale US alone in differentiating benign and malignant breast masses. Materials and Methods This prospective, 16-site study of 2105 women (study period: 12/21/2012 to 9/9/2015) compared Breast Imaging Reporting and Data System (BI-RADS) categories assigned by seven blinded independent readers to benign and malignant breast masses using OA/US versus US alone. BI-RADS 3, 4, or 5 masses assessed at diagnostic US with biopsy-proven histologic findings and BI-RADS 3 masses stable at 12 months were eligible. Independent readers reviewed US images obtained with the OA/US device, assigned a probability of malignancy (POM) and BI-RADS category, and locked results. The same independent readers then reviewed OA/US images, scored OA features, and assigned OA/US POM and a BI-RADS category. Specificity and sensitivity were calculated for US and OA/US. Benign and malignant mass upgrade and downgrade rates, positive and negative predictive values, and positive and negative likelihood ratios were compared. Results Of 2105 consented subjects with 2191 masses, 100 subjects (103 masses) were analyzed separately as a training population and excluded. An additional 202 subjects (210 masses) were excluded due to technical failures or incomplete imaging, 72 subjects (78 masses) due to protocol deviations, and 41 subjects (43 masses) due to high-risk histologic results. Of 1690 subjects with 1757 masses (1079 [61.4%] benign and 678 [38.6%] malignant masses), OA/US downgraded 40.8% (3078/7535) of benign mass reads, with a specificity of 43.0% (3242/7538, 99% confidence interval [CI]: 40.4%, 45.7%) for OA/US versus 28.1% (2120/7543, 99% CI: 25.8%, 30.5%) for the internal US of the OA/US device. OA/US exceeded US in specificity by 14.9% (P < .0001; 99% CI: 12.9, 16.9%). Sensitivity for biopsied malignant masses was 96

  18. Combining blue native polyacrylamide gel electrophoresis with liquid chromatography tandem mass spectrometry as an effective strategy for analyzing potential membrane protein complexes of Mycobacterium bovis bacillus Calmette-Guérin

    Directory of Open Access Journals (Sweden)

    Li Weijun

    2011-01-01

    Full Text Available Abstract Background Tuberculosis is an infectious bacterial disease in humans caused primarily by Mycobacterium tuberculosis, and infects one-third of the world's total population. Mycobacterium bovis bacillus Calmette-Guérin (BCG vaccine has been widely used to prevent tuberculosis worldwide since 1921. Membrane proteins play important roles in various cellular processes, and the protein-protein interactions involved in these processes may provide further information about molecular organization and cellular pathways. However, membrane proteins are notoriously under-represented by traditional two-dimensional polyacrylamide gel electrophoresis (2-D PAGE and little is known about mycobacterial membrane and membrane-associated protein complexes. Here we investigated M. bovis BCG by an alternative proteomic strategy coupling blue native PAGE to liquid chromatography tandem mass spectrometry (LC-MS/MS to characterize potential protein-protein interactions in membrane fractions. Results Using this approach, we analyzed native molecular composition of protein complexes in BCG membrane fractions. As a result, 40 proteins (including 12 integral membrane proteins, which were organized in 9 different gel bands, were unambiguous identified. The proteins identified have been experimentally confirmed using 2-D SDS PAGE. We identified MmpL8 and four neighboring proteins that were involved in lipid transport complexes, and all subunits of ATP synthase complex in their monomeric states. Two phenolpthiocerol synthases and three arabinosyltransferases belonging to individual operons were obtained in different gel bands. Furthermore, two giant multifunctional enzymes, Pks7 and Pks8, and four mycobacterial Hsp family members were determined. Additionally, seven ribosomal proteins involved in polyribosome complex and two subunits of the succinate dehydrogenase complex were also found. Notablely, some proteins with high hydrophobicity or multiple transmembrane

  19. Combining blue native polyacrylamide gel electrophoresis with liquid chromatography tandem mass spectrometry as an effective strategy for analyzing potential membrane protein complexes of Mycobacterium bovis bacillus Calmette-Guérin.

    Science.gov (United States)

    Zheng, Jianhua; Wei, Candong; Zhao, Lina; Liu, Liguo; Leng, Wenchuan; Li, Weijun; Jin, Qi

    2011-01-18

    Tuberculosis is an infectious bacterial disease in humans caused primarily by Mycobacterium tuberculosis, and infects one-third of the world's total population. Mycobacterium bovis bacillus Calmette-Guérin (BCG) vaccine has been widely used to prevent tuberculosis worldwide since 1921. Membrane proteins play important roles in various cellular processes, and the protein-protein interactions involved in these processes may provide further information about molecular organization and cellular pathways. However, membrane proteins are notoriously under-represented by traditional two-dimensional polyacrylamide gel electrophoresis (2-D PAGE) and little is known about mycobacterial membrane and membrane-associated protein complexes. Here we investigated M. bovis BCG by an alternative proteomic strategy coupling blue native PAGE to liquid chromatography tandem mass spectrometry (LC-MS/MS) to characterize potential protein-protein interactions in membrane fractions. Using this approach, we analyzed native molecular composition of protein complexes in BCG membrane fractions. As a result, 40 proteins (including 12 integral membrane proteins), which were organized in 9 different gel bands, were unambiguous identified. The proteins identified have been experimentally confirmed using 2-D SDS PAGE. We identified MmpL8 and four neighboring proteins that were involved in lipid transport complexes, and all subunits of ATP synthase complex in their monomeric states. Two phenolpthiocerol synthases and three arabinosyltransferases belonging to individual operons were obtained in different gel bands. Furthermore, two giant multifunctional enzymes, Pks7 and Pks8, and four mycobacterial Hsp family members were determined. Additionally, seven ribosomal proteins involved in polyribosome complex and two subunits of the succinate dehydrogenase complex were also found. Notablely, some proteins with high hydrophobicity or multiple transmembrane helixes were identified well in our work. In this

  20. A Bayesian geostatistical approach for evaluating the uncertainty of contaminant mass discharges from point sources

    Science.gov (United States)

    Troldborg, M.; Nowak, W.; Binning, P. J.; Bjerg, P. L.

    2012-12-01

    Estimates of mass discharge (mass/time) are increasingly being used when assessing risks of groundwater contamination and designing remedial systems at contaminated sites. Mass discharge estimates are, however, prone to rather large uncertainties as they integrate uncertain spatial distributions of both concentration and groundwater flow velocities. For risk assessments or any other decisions that are being based on mass discharge estimates, it is essential to address these uncertainties. We present a novel Bayesian geostatistical approach for quantifying the uncertainty of the mass discharge across a multilevel control plane. The method decouples the flow and transport simulation and has the advantage of avoiding the heavy computational burden of three-dimensional numerical flow and transport simulation coupled with geostatistical inversion. It may therefore be of practical relevance to practitioners compared to existing methods that are either too simple or computationally demanding. The method is based on conditional geostatistical simulation and accounts for i) heterogeneity of both the flow field and the concentration distribution through Bayesian geostatistics (including the uncertainty in covariance functions), ii) measurement uncertainty, and iii) uncertain source zone geometry and transport parameters. The method generates multiple equally likely realizations of the spatial flow and concentration distribution, which all honour the measured data at the control plane. The flow realizations are generated by analytical co-simulation of the hydraulic conductivity and the hydraulic gradient across the control plane. These realizations are made consistent with measurements of both hydraulic conductivity and head at the site. An analytical macro-dispersive transport solution is employed to simulate the mean concentration distribution across the control plane, and a geostatistical model of the Box-Cox transformed concentration data is used to simulate observed

  1. The effectiveness of FDG PET/CT for evaluation of intracardiac mass and pericardiac lesions

    International Nuclear Information System (INIS)

    Hwang, H. S; Yun, M. J.; Lee, J. D

    2004-01-01

    Fluorodeoxyglucose positron emission tomography has been known to be useful in diagnosis and staging of malignancy. FDG PET has high sensitivity and easily detects malignant lesions that are missed and overlooked in anatomic imaging modality. We assessed the impact of FDG PET/CT compared to echocardiogram and enhanced CT scan. Five patients of intra- and pericardiac lesions were included in this study. All patients underwent PET/CT(GE Discovery ST), enhanced CT scan and echocardiogram. Two patients were non-small cell lung cancer, one of RV metastatic mass, the other of pericardial metastasis in RV region. One of melanoma with systemic metastases, had RA malignant masses. One of suspicious lung cancer and intracardiac mass, has proved to benign LA thrombosis. One of lymphoma showed suspicious cardiac mass, but revealed no abnormality in echocardiogram. FDG PET/CT is sensitive and useful method to detect intra- and pericardiac mass in patients with suspected malignancy. All patients except lymphoma were correctly diagnosed using FDG PET/ICT

  2. Evaluation of mixing and mass transfer in a stirred pilot scale bioreactor utilizing CFD

    DEFF Research Database (Denmark)

    Bach, Christian; Yang, Jifeng; Larsson, Hilde Kristina

    2017-01-01

    Knowledge and prediction of mixing and mass transfer in agitated bioreactors is fundamental for process development and scale up. In particular key process parameters such as mixing time and volumetric mass transfer coefficient are essential for bioprocess development. In this work the mixing...... and mass transfer performance of a high power agitated pilot scale bioreactor has been characterized using a novel combination of computational fluid dynamics (CFD) and experimental investigations. The effect of turbulence inside the vessel was predicted using a standard RANS k-ε model. Mixing time...... transfer coefficients were in accordance with the experimental data. This work illustrates the possibility of predicting the two phase fluid dynamic performance of an agitated pilot scale bioreactor using validated CFD models. These models can be applied to illustrate the effect of changing the physical...

  3. Evaluation of fat-free mass by whole-body counter in Japanese healthy young adults

    International Nuclear Information System (INIS)

    Morita, N.; Takamura, N.; Murakami, T.; Jo, O.; Aoyagi, K.; Yamashita, S.; Okumura, Y.

    2007-01-01

    Whole-body counters (WBCs) are special instruments for measuring internal irradiation doses and are usually housed within or around nuclear facilities in the event of unexpected radiation emergencies. As a substantial proportion of total body potassium (TBK) is found in fat-free mass (FFM), FFM volume can be predicted from WBC-measured 40 K. We screened TBK in Japanese healthy young adults using a WBC and found strong linear correlations between TBK and lean body mass (LBM) and body mass index (r = 0.97, P<0.01 and r = 0.47, P<0.01, respectively). Multiple linear regression analysis, following adjustments for sex, indicates that only LBM has a significant correlation with TBK (P<0.01). These results strongly support the feasibility of using WBCs for estimating FFM. (authors)

  4. Application of Bayesian geostatistics for evaluation of mass discharge uncertainty at contaminated sites

    Science.gov (United States)

    Troldborg, Mads; Nowak, Wolfgang; Lange, Ida V.; Santos, Marta C.; Binning, Philip J.; Bjerg, Poul L.

    2012-09-01

    Mass discharge estimates are increasingly being used when assessing risks of groundwater contamination and designing remedial systems at contaminated sites. Such estimates are, however, rather uncertain as they integrate uncertain spatial distributions of both concentration and groundwater flow. Here a geostatistical simulation method for quantifying the uncertainty of the mass discharge across a multilevel control plane is presented. The method accounts for (1) heterogeneity of both the flow field and the concentration distribution through Bayesian geostatistics, (2) measurement uncertainty, and (3) uncertain source zone and transport parameters. The method generates conditional realizations of the spatial flow and concentration distribution. An analytical macrodispersive transport solution is employed to simulate the mean concentration distribution, and a geostatistical model of the Box-Cox transformed concentration data is used to simulate observed deviations from this mean solution. By combining the flow and concentration realizations, a mass discharge probability distribution is obtained. The method has the advantage of avoiding the heavy computational burden of three-dimensional numerical flow and transport simulation coupled with geostatistical inversion. It may therefore be of practical relevance to practitioners compared to existing methods that are either too simple or computationally demanding. The method is demonstrated on a field site contaminated with chlorinated ethenes. For this site, we show that including a physically meaningful concentration trend and the cosimulation of hydraulic conductivity and hydraulic gradient across the transect helps constrain the mass discharge uncertainty. The number of sampling points required for accurate mass discharge estimation and the relative influence of different data types on mass discharge uncertainty is discussed.

  5. Evaluation of online carbon isotope dilution mass spectrometry for the purity assessment of synthetic peptide standards

    Energy Technology Data Exchange (ETDEWEB)

    Díaz, Sergio Cueto; Ruiz Encinar, Jorge, E-mail: ruizjorge@uniovi.es; García Alonso, J. Ignacio, E-mail: jiga@uniovi.es

    2014-09-24

    Highlights: • Purity assessment of peptide standards applicable to any water soluble peptide. • Online {sup 13}C isotope dilution mass spectrometry. • Mass flow chromatogram from measured 44/45 isotope ratios. • Validation by the analysis of NIST 8327. - Abstract: We present a novel method for the purity assessment of peptide standards which is applicable to any water soluble peptide. The method is based on the online {sup 13}C isotope dilution approach in which the peptide is separated from its related impurities by liquid chromatography (LC) and the eluent is mixed post-column with a continuous flow of {sup 13}C-enriched sodium bicarbonate. An online oxidation step using sodium persulfate in acidic media at 99 °C provides quantitative oxidation to {sup 12}CO{sub 2} and {sup 13}CO{sub 2} respectively which is extracted to a gaseous phase with the help of a gas permeable membrane. The measurement of the isotope ratio 44/45 in the mass spectrometer allows the construction of the mass flow chromatogram. As the only species that is finally measured in the mass spectrometer is CO{sub 2}, the peptide content in the standard can be quantified, on the base of its carbon content, using a generic primary standard such as potassium hydrogen phthalate. The approach was validated by the analysis of a reference material (NIST 8327), and applied to the quantification of two commercial synthetic peptide standards. In that case, the results obtained were compared with those obtained using alternative methods, such as amino acid analysis and ICP-MS. The results obtained proved the value of the method for the fast, accurate and precise mass purity assignment of synthetic peptide standards.

  6. Added value of shear-wave elastography for evaluation of breast masses detected with screening US imaging.

    Science.gov (United States)

    Lee, Su Hyun; Chang, Jung Min; Kim, Won Hwa; Bae, Min Sun; Seo, Mirinae; Koo, Hye Ryoung; Chu, A Jung; Gweon, Hye Mi; Cho, Nariya; Moon, Woo Kyung

    2014-10-01

    To evaluate the additional value of shear-wave elastography (SWE) to B-mode ultrasonography (US) and to determine an appropriate guideline for the combined assessment of screening US-detected breast masses. This study was conducted with institutional review board approval, and written informed consent was obtained. From March 2010 to February 2012, B-mode US and SWE were performed in 159 US-detected breast masses before biopsy. For each lesion, Breast Imaging Reporting and Data System (BI-RADS) category on B-mode US images and the maximum stiffness color and elasticity values on SWE images were assessed. A guideline for adding SWE data to B-mode US was developed with the retrospective cohort to improve diagnostic performance in sensitivity and specificity and was validated in a distinct prospective cohort of 207 women prior to biopsy. Twenty-one of 159 masses in the development cohort and 12 of 207 breast masses in the validation cohort were malignant. In the development cohort, when BI-RADS category 4a masses showing a dark blue color or a maximum elasticity value of 30 kPa or less on SWE images were downgraded to category 3, specificity increased from 9.4% (13 of 138) to 59.4% (82 of 138) and 57.2% (79 of 138) (P breast masses. BI-RADS category 4a masses detected at US screening that showed a dark blue color or a maximum elasticity value of 30 kPa or less on SWE images can be safely followed up instead of performing biopsy. © RSNA, 2014.

  7. Artificial Intelligence-Based Student Learning Evaluation: A Concept Map-Based Approach for Analyzing a Student's Understanding of a Topic

    Science.gov (United States)

    Jain, G. Panka; Gurupur, Varadraj P.; Schroeder, Jennifer L.; Faulkenberry, Eileen D.

    2014-01-01

    In this paper, we describe a tool coined as artificial intelligence-based student learning evaluation tool (AISLE). The main purpose of this tool is to improve the use of artificial intelligence techniques in evaluating a student's understanding of a particular topic of study using concept maps. Here, we calculate the probability distribution of…

  8. Evaluation of ECG-gated [(11)C]acetate PET for measuring left ventricular volumes, mass, and myocardial external efficiency.

    Science.gov (United States)

    Hansson, Nils Henrik; Tolbod, Lars; Harms, Johannes; Wiggers, Henrik; Kim, Won Yong; Hansen, Esben; Zaremba, Tomas; Frøkiær, Jørgen; Jakobsen, Steen; Sørensen, Jens

    2016-08-01

    Noninvasive estimation of myocardial external efficiency (MEE) requires measurements of left ventricular (LV) oxygen consumption with [(11)C]acetate PET in addition to LV stroke volume and mass with cardiovascular magnetic resonance (CMR). Measuring LV geometry directly from ECG-gated [(11)C]acetate PET might enable MEE evaluation from a single PET scan. Therefore, we sought to establish the accuracy of measuring LV volumes, mass, and MEE directly from ECG-gated [(11)C]acetate PET. Thirty-five subjects with aortic valve stenosis underwent ECG-gated [(11)C]acetate PET and CMR. List mode PET data were rebinned into 16-bin ECG-gated uptake images before measuring LV volumes and mass using commercial software and compared to CMR. Dynamic datasets were used for calculation of mean LV oxygen consumption and MEE. LV mass, volumes, and ejection fraction measured by CMR and PET correlated strongly (r = 0.86-0.92, P PET (P PET-based MEE, corrected for bias, correlated fairly with PET/CMR-based MEE (r = 0.60, P PET-based MEE bias was strongly associated with LV wall thickness. Although analysis-related improvements in accuracy are recommended, LV geometry estimated from ECG-gated [(11)C]acetate PET correlate excellently with CMR and can indeed be used to evaluate MEE.

  9. 99mTc-HYNIC-TOC imaging in the evaluation of pancreatic masses which are potential neuroendocrine tumors.

    Science.gov (United States)

    Qiao, Zhen; Zhang, Jingjing; Jin, Xiaona; Huo, Li; Zhu, Zhaohui; Xing, Haiqun; Li, Fang

    2015-05-01

    The aim of this investigation was to determine the accuracy of the findings and the diagnoses of Tc-hydrazinonicotinyl-Tyr3-octreotide scan (Tc-HYNIC-TOC imaging) in patients with pancreatic masses which were potential neuroendocrine tumors. Records of total 20 patients with pancreatic masses were retrospectively reviewed. All of the patients had been revealed by abdominal contrast CT and possibility of neuroendocrine tumors could not be excluded by CT imaging before Tc-HYNIC-TOC imaging. Tc-HYNIC-TOC imaging was performed at 1 and 4 hours post-tracer injection, and SPECT/CT images of the abdomen were also acquired. The image findings were compared to final diagnoses which were made from pathological examination. Among all 20 pancreatic masses evaluated, there were 16 malignant lesions which included 1 ductal adenocarcinoma and 15 neuroendocrine tumors. Tc-HYNIC-TOC imaging identified 14 of 15 pancreatic neuroendocrine tumors and excluded 4 of 5 lesions which were not neuroendocrine tumors. The overall sensitivity, specificity, and accuracy was therefore 93.3% (14 of 15), 80% (4 of 5), and 90.0% (18 of 20), respectively, in our patient population. Tc-HYNIC-TOC imaging provides reasonable accuracy in the evaluation pancreatic mass suspected to be neuroendocrine tumors.

  10. Evaluation of information-theoretic similarity measures for content-based retrieval and detection of masses in mammograms

    International Nuclear Information System (INIS)

    Tourassi, Georgia D.; Harrawood, Brian; Singh, Swatee; Lo, Joseph Y.; Floyd, Carey E.

    2007-01-01

    The purpose of this study was to evaluate image similarity measures employed in an information-theoretic computer-assisted detection (IT-CAD) scheme. The scheme was developed for content-based retrieval and detection of masses in screening mammograms. The study is aimed toward an interactive clinical paradigm where physicians query the proposed IT-CAD scheme on mammographic locations that are either visually suspicious or indicated as suspicious by other cuing CAD systems. The IT-CAD scheme provides an evidence-based, second opinion for query mammographic locations using a knowledge database of mass and normal cases. In this study, eight entropy-based similarity measures were compared with respect to retrieval precision and detection accuracy using a database of 1820 mammographic regions of interest. The IT-CAD scheme was then validated on a separate database for false positive reduction of progressively more challenging visual cues generated by an existing, in-house mass detection system. The study showed that the image similarity measures fall into one of two categories; one category is better suited to the retrieval of semantically similar cases while the second is more effective with knowledge-based decisions regarding the presence of a true mass in the query location. In addition, the IT-CAD scheme yielded a substantial reduction in false-positive detections while maintaining high detection rate for malignant masses

  11. Why Band-Aids Don't Work: Analyzing and Evaluating No Child Left Behind (NCLB) in Light of Constructivist Philosophy, Theory, and Practice

    Science.gov (United States)

    Shapiro, Arthur; Thompson, Alana S.

    2008-01-01

    In this paper the No Child Left Behind (NCLB) Act, a top-down, one-size-fits-all coercive nostrum constructed by politicians purportedly to improve all American public schools that piddles with symptoms rather than deal with root causes, is first delineated and analyzed. Its departure from local educational governance to an accountability-focused…

  12. Evaluation of water content in rock mass by electromagnetic and resistivity tomography. Denjiha, hiteiko tomography ni yoru ganban no gansui jotai hyoka

    Energy Technology Data Exchange (ETDEWEB)

    Inaba, T; Inoue, M; Matsumoto, K [Kajima Corp., Tokyo (Japan)

    1993-10-31

    As a method to evaluate the rock mass, electromagnetic tomography and resistivity tomography were tested on the original site. The electromagnetic tomography can tomographically analyze the propagation velocity and initial amplitude damping. The resistivity tomography uses a finite element method from the initial resistivity distribution model and finally gives a model which is nearly equal to the actual resistivity distribution. Both the above tomographic analyses can detect the crushed spot as a low velocity, high damping and low resistivity spot. However, the electromagnetic tomography could detect finer structure than the resistivity tomography. The water content of rock mass was evaluated from the damping coefficient which was given by the amplitude damping tomography of electromagnetic wave. If it is compared with the water content which is given by the dielectric constant of velocity tomography, there partially exists discrepancy between both, because the damping coefficient contains information on cracks which disperse and reflect the electromagnetic wave. Between the resistivity and porosity, there exists a known experimental formula, which was satisfied by the presently given resistivity. 9 refs., 10 figs.

  13. Evaluation of false positive responses by mass spectrometry and ion mobility spectrometry for the detection of trace explosives in complex samples

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, C.L., E-mail: clcrawf@sandia.gov; Hill, H.H.

    2013-09-17

    Graphical abstract: -- Highlights: •First study to use (−)SESI-IM-TOFMS to analyze complex mixtures of personal care products. •The study demonstrated, by identifying mobility and mass interferents with explosive signatures, which, if used separately, neither IMS nor MS alone would prevent every false positive for explosives when detected in the presence of a complex sample matrix. •Ingredients in common household cleaning products were shown to either enhance or suppress the ionization of explosives in a SESI-IM-TOFMS analysis. •Mobility separation provided real-time separation of ion species that indicated overlapping isotope peak patterns -- Abstract: Secondary electrospray ionization-ion mobility-time of flight mass spectrometry (SESI-IM-TOFMS) was used to evaluate common household products and food ingredients for any mass or mobility responses that produced false positives for explosives. These products contained ingredients which shared the same mass and mobility drift time ranges as the analyte ions for common explosives. The results of this study showed that the vast array of compounds in these products can cause either mass or mobility false positive responses. This work also found that two ingredients caused either enhanced or reduced ionization of the target analytes. Another result showed that an IMS can provide real-time separation of ion species that impede accurate mass identifications due to overlapping isotope peak patterns. The final result of this study showed that, when mass and mobility values were used to identify an ion, no false responses were found for the target explosives. The wider implication of these results is that the possibility exists for even greater occurrences of false responses from complex mixtures found in common products. Neither IMS nor MS alone can provide 100% assurance from false responses. IMS, due to its low cost, ease of operation, rugged reliability, high sensitivity and tunable selectivity, will remain

  14. Comparative Study for Evaluation of Mass Flow Rate for Simple Solar Still and Active with Heat Pump

    OpenAIRE

    Hidouri Khaoula; Benhmidene Ali; Chaouachi Bechir; Ravishankar Sathyamurthy

    2017-01-01

    In isolated and arid areas, especially in the almost Maghreb regions, the abundant solar radiation intensity along the year and the available brackish water resources are the two favorable conditions for using solar desalination technology to produce fresh water. The present study is based on the use of three groups of correlation, for evaluating mass transfer. Theoretical results are compared with those obtained experimentally for a Simple Solar Distiller (SSD) and a Simple Solar Distiller H...

  15. Evaluating heat-related mortality in Korea by objective classifications of 'air masses'

    Czech Academy of Sciences Publication Activity Database

    Kyselý, Jan; Huth, Radan; Kim, J.

    2010-01-01

    Roč. 30, č. 10 (2010), s. 1484-1501 ISSN 0899-8418 R&D Projects: GA ČR GC205/07/J044 Institutional research plan: CEZ:AV0Z30420517 Keywords : weather type classifications * air masses * biometeorology * human mortality * South Korea Subject RIV: DG - Athmosphere Sciences, Meteorology Impact factor: 2.479, year: 2010

  16. Exact evaluation of the mass gap in the O(N) non-linear sigma model

    International Nuclear Information System (INIS)

    Gliozzi, F.

    1985-01-01

    When the Luescher nonlocal quantum charges are transcribed in a lattice hamiltonian formalism, they become unusually manageable. Their conservation induces an exact expression for the mass of the low-lying vector multiplet of the theory. Its value in units Λsub(PV) (Pauli-Villars scale) reads simple m=exp[1/(N-2)]Λsub(PV). (orig.)

  17. Clinical study evaluating bone mineral mass in the radius during skeletal growth. Single photon absorptiometry

    Energy Technology Data Exchange (ETDEWEB)

    Hagino, Hiroshi

    1989-01-01

    Using 125-I single photon absorptiometry, bone mineral measurements were performed on 206 healthy Japanese children (2 to 19 years of age). Bone mineral content (BMC), bone width (BW) and BMC/BW values were determined for the radius at distal 1/6 site (metaphysis) and distal 1/3 site (diaphysis). BMC/BW values at both sites correlated well with body height and weight. Bone mass in the diaphysis (distal 1/3 site) increased linearly during the 2-19 years of skeletal growth, but bone mass in the metaphysis (1/6 site) increased steeply during the pubertal period. In children receiving glucocorticoid therapy, bone mass was reduced in proportion to the duration of drug administration. In children under anticonvulsant therapy, the yearly increse in bone mass was significantly low especially in those patients with poor physical activity levels. Bone mineral decrease in the radius occurred in the children with hypopituitalism, hypothyroidism (cretinism), hyperthyroidism and Turner's syndrome.

  18. Uncertainty evaluation of mass discharge estimates from a contaminated site using a fully Bayesian framework

    DEFF Research Database (Denmark)

    Troldborg, Mads; Nowak, W.; Tuxen, N.

    2010-01-01

    for each of the conceptual models considered. The probability distribution of mass discharge is obtained by combining all ensembles via BMA. The method was applied to a trichloroethylene-contaminated site located in northern Copenhagen. Four essentially different conceptual models based on two source zone...

  19. Evaluation of magnetization transfer ratio in ascites and pelvic cystic masses

    Energy Technology Data Exchange (ETDEWEB)

    Okada, Susumu [Nippon Medical School, Inba, Chiba (Japan). Chiba-Hokuso Hospital; Kato, Tomoyasu; Yamashita, Takashi [and others

    1997-12-01

    To investigate the feasibility of magnetization transfer contrast (MTC) in characterization of pelvic cystic masses and ascites, in vitro studies were performed. Cystic fluids were taken from operative specimens of ten ovarian cystic masses (five mucinous cystadenomas, one cystadenocarcinoma, two serous cystadenocarcinomas, two clear cell carcinomas) and three non-ovarian pelvic cysts (one paraovarian cyst, one pseudomyxoma peritonei, one pelvic abscess). Samples of ascitic flied were drawn by peritoneal puncture in twenty patients (thirteen with peritonitis carcinomatosa, five with liver dysfunction, two with renal dysfunction). Total protein content in ascitic fluids was measured. Magnetization transfer ratio (MTR) was calculated by the signal intensities under the gradient echo sequence with and without the application of off-resonance pulses. The relative signal intensities (RSI) relative to water in T{sub 1} and T{sub 2} weighted images were obtained using spin echo sequence. There was no correlation between histological type of pelvic mass and MTR and RSI. Good correlation (R{sup 2}=0.761) was obtained between MTR and protein content in ascitic fluids, whereas no correlation was noted between RSI and protein content in ascitic fluids. These results suggest that MTC is not useful in the characterization of pelvic masses but is applicable in the differentiation between exudative ascites and transudative ascites. (author)

  20. Greenland ice sheet surface mass balance: evaluating simulations and making projections with regional climate models

    NARCIS (Netherlands)

    Rae, J.G.L.; Aðalgeirsdóttir, G.; Edwards, T.L.; Fettweis, X.; Gregory, J.M.; Hewitt, H.T.; Lowe, J.A.; Lucas-Picher, P.; Mottram, R.H.; Payne, A.J.; Ridley, J.K.; Shannon, S.R.; van de Berg, W.J.; van de Wal, R.S.W.; van den Broeke, M.R.

    2012-01-01

    Four high-resolution regional climate models (RCMs) have been set up for the area of Greenland, with the aim of providing future projections of Greenland ice sheet surface mass balance (SMB), and its contribution to sea level rise, with greater accuracy than is possible from coarser-resolution

  1. Population-Based Evaluation of the "Livelighter" Healthy Weight and Lifestyle Mass Media Campaign

    Science.gov (United States)

    Morley, B.; Niven, P.; Dixon, H.; Swanson, M.; Szybiak, M.; Shilton, T.; Pratt, I. S.; Slevin, T.; Hill, D.; Wakefield, M.

    2016-01-01

    The Western Australian (WA) "LiveLighter" (LL) mass media campaign ran during June-August and September-October 2012. The principal campaign ad graphically depicts visceral fat of an overweight individual ("why" change message), whereas supporting ads demonstrate simple changes to increase activity and eat healthier…

  2. Differential predictors of transient stress versus posttraumatic stress disorder: evaluating risk following targeted mass violence.

    Science.gov (United States)

    Miron, Lynsey R; Orcutt, Holly K; Kumpula, Mandy J

    2014-11-01

    Schools have become a common incident site for targeted mass violence, including mass shootings. Although exposure to mass violence can result in significant distress, most individuals are able to fully recover over time, while a minority develop more pervasive pathology, such as PTSD. The present study investigated how several pre- and posttrauma factors predict posttraumatic stress symptoms (PTSS) in both the acute and distal aftermath of a campus mass shooting using a sample with known levels of pretrauma functioning (N=573). Although the largest proportion of participants evidenced resilience following exposure to the event (46.1%), many reported high rates of PTSS shortly after the shooting (42.1%) and a smaller proportion (11.9%) met criteria for probable PTSD both in the acute and more distal aftermath of the event. While several preshooting factors predicted heightened PTSS after the shooting, prior trauma exposure was the only preshooting variable shown to significantly differentiate between those who experienced transient versus prolonged distress. Among postshooting predictors, individuals reporting greater emotion dysregulation and peritraumatic dissociative experiences were over four times more likely to have elevated PTSS 8months postshooting compared with those reporting less dysregulation and dissociative experiences. Individuals with less exposure to the shooting, fewer prior traumatic experiences, and greater satisfaction with social support were more likely to recover from acute distress. Overall, results suggest that, while pretrauma factors may differentiate between those who are resilient in the aftermath of a mass shooting and those who experience heightened distress, several event-level and posttrauma coping factors help distinguish between those who eventually recover and those whose PTSD symptoms persist over time. Copyright © 2014. Published by Elsevier Ltd.

  3. A neutron activation analyzer

    International Nuclear Information System (INIS)

    Westphal, G.P.; Lemmel, H.; Grass, F.; De Regge, P.P.; Burns, K.; Markowicz, A.

    2005-01-01

    Dubbed 'Analyzer' because of its simplicity, a neutron activation analysis facility for short-lived isomeric transitions is based on a low-cost rabbit system and an adaptive digital filter which are controlled by a software performing irradiation control, loss-free gamma-spectrometry, spectra evaluation, nuclide identification and calculation of concentrations in a fully automatic flow of operations. Designed for TRIGA reactors and constructed from inexpensive plastic tubing and an aluminum in-core part, the rabbit system features samples of 5 ml and 10 ml with sample separation at 150 ms and 200 ms transport time or 25 ml samples without separation at a transport time of 300 ms. By automatically adapting shaping times to pulse intervals the preloaded digital filter gives best throughput at best resolution up to input counting rates of 10 6 cps. Loss-free counting enables quantitative correction of counting losses of up to 99%. As a test of system reproducibility in sample separation geometry, K, Cl, Mn, Mg, Ca, Sc, and V have been determined in various reference materials at excellent agreement with consensus values. (author)

  4. Evaluation of MALDI-TOF mass spectrometry for the competitiveness analysis of selected indigenous cowpea (Vigna unguiculata L. Walp.) Bradyrhizobium strains from Kenya.

    Science.gov (United States)

    Ndungu, Samuel Mathu; Messmer, Monika M; Ziegler, Dominik; Thuita, Moses; Vanlauwe, Bernard; Frossard, Emmanuel; Thonar, Cécile

    2018-06-01

    Cowpea N 2 fixation and yield can be enhanced by selecting competitive and efficient indigenous rhizobia. Strains from contrasting agro-ecologies of Kilifi and Mbeere (Kenya) were screened. Two pot experiments were established consisting of 13 Bradyrhizobium strains; experiment 1 (11 Mbeere + CBA + BK1 from Burkina Faso), experiment 2 (12 Kilifi + CBA). Symbiotic effectiveness was assessed (shoot biomass, SPAD index and N uptake). Nodule occupancy of 13 simultaneously co-inoculated strains in each experiment was analyzed by matrix-assisted laser desorption/ionization time of flight (MALDI-TOF) mass spectrometry (MS) to assess competitiveness. Strains varied in effectiveness and competitiveness. The four most efficient strains were further evaluated in a field trial in Mbeere during the 2014 short rains. Strains from bacteroids of cowpea nodules from pot and field experiments were accurately identified as Bradyrhizobium by MALDI-TOF based on the SARAMIS™ database. In the field, abundant indigenous populations 7.10 × 10 3 rhizobia g -1 soil, outcompeted introduced strains. As revealed by MALDI-TOF, indigenous strains clustered into six distinct groups (I, II, III, IV, V and VI), group III were most abundant occupying 80% of nodules analyzed. MALDI-TOF was rapid, affordable and reliable to identify Bradyrhizobium strains directly from nodule suspensions in competition pot assays and in the field with abundant indigenous strains thus, its suitability for future competition assays. Evaluating strain competitiveness and then symbiotic efficacy is proposed in bioprospecting for potential cowpea inoculant strains.

  5. A mise-a'-la-masse method for landfill contaminant plume evaluation

    International Nuclear Information System (INIS)

    Rowley, T.H.; Donaldson, P.R.; Osiensky, J.L.; Welham, J.A.

    1994-01-01

    A mise-a'-la-masse survey was conducted down gradient of the Bannock County Landfill, in Fort Hall Canyon, Idaho in 1993. Data collected during the survey were compared to seismic refraction data also collected at the site. The site at the mouth of Fort Hall Canyon is ideal for use of the mise-a'-la-masse method to characterize a contaminant plume under actual field conditions. A contaminant plume is believed to emanate from the Bannock County Landfill. The plume contains high concentrations of Dense Non-Aqueous Phase Liquids (DNAPLs) plus inorganic groundwater contaminants. These DNAPLs and inorganics have been detected in nearby domestic and municipal water supply wells. The field site is relatively free of cultural interference that would adversely affect electrical-potential fields. 18 refs., 4 figs

  6. Experimental analysis and evaluation of the mass transfer process in a trickle-bed reactor

    Directory of Open Access Journals (Sweden)

    J.D. Silva

    2003-10-01

    Full Text Available A transient experimental analysis of a three-phase descendent-cocurrent trickle-bed H2O/CH4-Ar/g -Al2O3 system was made using the stimulus-response technique, with the gas phase as a reference. Methane was used as a tracer and injected into the argon feed and the concentration vs time profiles were obtained at the entrance and exit of the bed, which were maintained at 298K and 1.013 10(5 Pa. A mathematical model for the tracer was developed to estimate the axial dispersion overall gas-liquid mass transfer and liquid-solid mass transfer coefficients. Experimental and theoretical results were compared and shown to be in good agreement. The model was validated by two additional experiments, and the values of the coefficients obtained above were confirmed.

  7. Review and evaluation of spark source mass spectrometry as an analytical method

    International Nuclear Information System (INIS)

    Beske, H.E.

    1981-01-01

    The analytical features and most important fields of application of spark source mass spectrometry are described with respect to the trace analysis of high-purity materials and the multielement analysis of technical alloys, geochemical and cosmochemical, biological and radioactive materials, as well as in environmental analysis. Comparisons are made to other analytical methods. The distribution of the method as well as opportunities for contract analysis are indicated and developmental tendencies discussed. (orig.) [de

  8. Evaluation of a mass screening of breast cancer with mammography in personnel of regional public schools

    International Nuclear Information System (INIS)

    Saito, Yoshihiro; Muto, Taisei; Asanuma, Taku; Horikoshi, Akira; Tsuchihara, Katsuo

    2009-01-01

    We have examined a total of 15,224 women in our hospital aiming at a mass screening of breast cancer with mammography (MMG) during the last 8 years. Subjected women were teachers or staffs of public schools in six prefectures in the Tohoku area. More than 90% of them were under 50 years old and women younger than 49 accounted for about half of them. A recall rate was 3.8%, and breast cancer was found in 55 women (0.36%) and the ratio of cancers diagnosed among recalled women was 9.5%. Twenty-one point eight percent of detected cancers were associated with calcification. The average diameter of the detected tumors in the screening group was 1.6 cm, whereas that of outpatients (controls) was 2.5 cm. Stage 0 and I cancer cases in the screening group accounted for 82.0%, whereas those in the outpatient group, 49.6%, indicating a significant increase in detection rate of early breast cancer in the screening compared to the outpatients group. However, detection rate of breast masses was 76.7% of all cases of breast tumor by means of MMG, versus 86.0% by means of physical examination. These results suggest that the mass screening by using physical examination and MMG, as well as ultrasonography, may provide a better clinical application for precise diagnosis, when it is done for working women in the regional public schools who are younger. (author)

  9. Bronsted acid site number evaluation using isopropylamine decomposition on Y-zeolite contaminated with vanadium in a simultaneous DSC-TGA analyzer

    International Nuclear Information System (INIS)

    Osorio Perez, Yonnathan; Forero, Liliam Alexandra Palomeque; Torres, Diana Vanessa Cristiano; Trujillo, Carlos Alexander

    2008-01-01

    Acid-site catalyzed decomposition of isopropylamine was followed in a simultaneous DSC-TGA analyzer. USY zeolite samples with and without vanadium were studied. Results show that acid sites number decreases linearly with vanadium concentration in zeolite indicating that vanadium neutralizes acid sites on catalyst and the metal is able to move on the surface of the solid. The neutralizing species probably contain only one vanadium atom. The reaction enthalpy plus desorption heat of the products show that vanadium preferentially neutralizes the strongest acid sites on the zeolite. The application of the simultaneous DSC-TGA technique to quantify Bronsted acid sites on solids by this reaction is novel

  10. On-Demand Urine Analyzer

    Science.gov (United States)

    Farquharson, Stuart; Inscore, Frank; Shende, Chetan

    2010-01-01

    A lab-on-a-chip was developed that is capable of extracting biochemical indicators from urine samples and generating their surface-enhanced Raman spectra (SERS) so that the indicators can be quantified and identified. The development was motivated by the need to monitor and assess the effects of extended weightlessness, which include space motion sickness and loss of bone and muscle mass. The results may lead to developments of effective exercise programs and drug regimes that would maintain astronaut health. The analyzer containing the lab-on-a- chip includes materials to extract 3- methylhistidine (a muscle-loss indicator) and Risedronate (a bone-loss indicator) from the urine sample and detect them at the required concentrations using a Raman analyzer. The lab-on- a-chip has both an extractive material and a SERS-active material. The analyzer could be used to monitor the onset of diseases, such as osteoporosis.

  11. Evaluation of autoradiographs and images of biological objects with the electronically operating image analyzer 'Densitron II'. II. Determination of the specific and total radioactivity of single cells

    Energy Technology Data Exchange (ETDEWEB)

    Hess, J; Korn, U; Freyer, K; Ermisch, A [Karl-Marx-Universitaet, Leipzig (German Democratic Republic). Sektion Biowissenschaften; Akademie der Wissenschaften der DDR, Leipzig. Zentralinstitut fuer Isotopen- und Strahlenforschung)

    1976-01-01

    Using the TV image analyzer Densitron, transparencies and areas can be measured by the grey value discrimination method equidensitometry. The time, necessary for one measurement, is approximately 1 min, the standard deviations do not exceed 2%. Microscopical objects such as single cells can be analyzed by this method. Photo-blackings and areas have been measured in autoradiographs of goldfish brain-sections after injection of /sup 3/H-phenylalanine. As a parallel, blacking and area calibration curves were obtained which allowed a conversion of the relative values into absolute ones. Using this conversion method, neurons of different brain regions were in the range from 104 to 1476..mu..m/sup 2/ in area and from 4.17 to 14.43..mu..Ci . cm/sup -3/ in specific radioactivity. The standard deviations of the absolute values were 6 and 4.5%, respectively. On the basis of these and additional values (thickness of section, number of sections per cell), calculations of the total radioactivity of a cell section or the whole cell can be made.

  12. Cytosolic distributions of highly toxic metals Cd and Tl and several essential elements in the liver of brown trout (Salmo trutta L.) analyzed by size exclusion chromatography and inductively coupled plasma mass spectrometry.

    Science.gov (United States)

    Dragun, Zrinka; Krasnići, Nesrete; Kolar, Nicol; Filipović Marijić, Vlatka; Ivanković, Dušica; Erk, Marijana

    2018-05-15

    Cytosolic distributions of nonessential metals Cd and Tl and seven essential elements among compounds of different molecular masses were studied in the liver of brown trout (Salmo trutta) from the karstic Krka River in Croatia. Analyses were done by size exclusion high performance liquid chromatography and high resolution inductively coupled plasma mass spectrometry. Common feature of Cd and Tl, as highly toxic elements, was their distribution within only two narrow peaks. The increase of cytosolic Cd concentrations was reflected in marked increase of Cd elution within low molecular mass peak (maximum at ∼15 kDa), presumably containing metallothioneins (MTs), which indicated successful Cd detoxification in brown trout liver under studied exposure conditions. Contrary, the increase of cytosolic Tl concentrations was reflected in marked increase of Tl elution within high molecular mass peak (maximum at 140 kDa), which probably indicated incomplete Tl detoxification. Common feature of the majority of studied essential elements was their distribution within more peaks, often broad and not well resolved, which is consistent with their numerous physiological functions. Among observed associations of essential metals/nonmetal to proteins, the following could be singled out: Cu and Zn association to MTs, Fe association to storage protein ferritin, and Se association to compounds of very low molecular masses (<5 kDa). The obtained results present the first step towards identification of metal-binding compounds in hepatic cytosol of brown trout, and thus a significant contribution to better understanding of metal fate in the liver of that important bioindicator species. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. Magnetic resonance evaluation of cardiac thrombi and masses by T1 and T2 mapping: an observational study.

    Science.gov (United States)

    Caspar, Thibault; El Ghannudi, Soraya; Ohana, Mickaël; Labani, Aïssam; Lawson, Aubrietia; Ohlmann, Patrick; Morel, Olivier; De Mathelin, Michel; Roy, Catherine; Gangi, Afshin; Germain, Philippe

    2017-04-01

    The purpose of this work was to evaluate CMR T1 and T2 mapping sequences in patients with intracardiac thrombi and masses in order to assess T1 and T2 relaxometry usefulness and to allow better etiological diagnosis. This observational study of patients scheduled for routine CMR was performed from September 2014 to August 2015. All patients referred to our department for a 1.5 T CMR were screened to participate. T1 mapping were acquired before and after Gadolinium injection; T2 mapping images were obtained before injection. 41 patients were included. 22 presented with cardiac thrombi and 19 with cardiac masses. The native T1 of thrombi was 1037 ± 152 ms (vs 1032 ± 39 ms for myocardium, p = 0.88; vs 1565 ± 88 ms for blood pool, p T2 were 74 ± 13 ms (vs 51 ± 3 ms for myocardium, p T2 consistently >70 ms. T1 and T2 mapping CMR sequences can be useful and represent a new approach for the evaluation of cardiac thrombi and masses.

  14. Air mass origins by back trajectory analysis for evaluating atmospheric 210Pb concentrations at Rokkasho, Aomori, Japan

    International Nuclear Information System (INIS)

    Akata, N.; Kawabata, H.; Hasegawa, H.; Kondo, K.; Chikuchi, Y.; Hisamatsu, S.; Inaba, J.; Sato, T.

    2009-01-01

    Atmospheric concentrations of 210 Pb change with various factors such as meso-scale meteorological conditions. We have already reported the biweekly atmospheric 210 Pb concentrations in Rokkasho, Japan for 5 years and found that they had clear seasonal variations: low concentrations in summer and high values in winter to spring. To study the reasons for the seasonal variations, the origins of the air mass flowing to Rokkasho were analyzed by 3-D backward air mass trajectory analysis. Routes of the calculated trajectories were classified into four regions: northeastern and southeastern Asian Continent, sea and other regions. The atmospheric 210 Pb concentrations were well correlated with the frequency of the routes through the northeastern Asian Continent. A non-linear multiple regression analysis of the 210 Pb concentrations and the relative frequencies of the four routes showed good fitting of the predicted values to the observed ones, and indicated that the atmospheric 210 Pb concentrations in Rokkasho depended on the frequency of the air mass from the northeastern Asian Continent. (author)

  15. Evaluation of the LTQ-Orbitrap mass spectrometer for the analysis of polymerase chain reaction products.

    Science.gov (United States)

    Manduzio, Hélène; Ezan, Eric; Fenaille, François

    2010-12-30

    We have investigated the potential and robustness of the off-line coupling of polymerase chain reaction (PCR) with electrospray ionization mass spectrometry (ESI-MS), for further applications in the screening of single-nucleotide polymorphisms (SNPs). This was based on recently reported data demonstrating that anion-exchange solid-phase extraction was the most efficient technique for efficiently desalting PCR products, with a recovery of ∼70%. Results showed that this purification approach efficiently removes almost all the chemicals commonly added to PCR buffers. ESI-MS analysis of a model 114-bp PCR product performed on the LTQ-Orbitrap instrument demonstrated that detection limits in the nM range along with an average mass measurement uncertainty of 9.15 ± 7.11 ppm can be routinely obtained using an external calibration. The PCR/ESI-MS platform was able to detect just a few copies of a targeted oligonucleotide. However, it was shown that if two PCR products are present in a mixture in a ratio higher than 10 to 1, the lower abundance one might not be reproducibly detected. Applications to SNPs demonstrated that an LTQ-Orbitrap with a resolution of 30 000 (at m/z 400) easily identified a single (A ↔ G) switch, i.e. a 16 Da difference, in binary mixtures of ∼ 35 kDa PCR products. Complementary experiments also showed that the combination of endonucleases and ESI-MS could be used to confirm base composition and sequence, and thus to screen for unknown polymorphisms in specific sequences. For example, a single (T ↔ A) switch (9 Da mass difference) was successfully identified in a 114-bp PCR product. Copyright © 2010 John Wiley & Sons, Ltd.

  16. Evaluation Of Mass Market Devices For The Documentation Of The Cultural Heritage

    Science.gov (United States)

    Aicardi, I.; Lingua, A.; Piras, M.

    2014-06-01

    The cultural and artistic heritage has always been at the center of activities aimed at its preservation and enhancement. Italy is a country particularly rich in terms of heritage to be protected, where the high-risk due to natural hazard, as earthquakes, landslides and floods, which are adds to human activities, contribute to make the heritage more frail, land needs to be safeguarded and enhanced and new mass market technology can be considered as innovative tools for the documentation of cultural heritage. In order to increase our country on the artistic point of view, it must be known in an historical and cultural way. Moreover, it is important also to define the cultural heritage on metric terms, to be able to describe and represent it with the best approach, with the purpose to offer to the people who comes to visit our beautiful country, the reliable model of some important object, that is no longer in exposition. The possibility to use the mass-market devices can allow us to realize it, because they are available for the greater part of the visitors, in a photogrammetric way to reconstruct our models. In the last years, these devices have been very improved and the embedded sensors are becoming more and more efficient in terms of precision and reliability. Also several small video cameras are now used to document our travels and activities and to share them through Internet. In this scenario, the aim of this research is to study and validate the possibility to use mass-market technology for this purpose, testing four different devices (smartphones and video cameras) for the documentation of the cultural heritage.

  17. Web server attack analyzer

    OpenAIRE

    Mižišin, Michal

    2013-01-01

    Web server attack analyzer - Abstract The goal of this work was to create prototype of analyzer of injection flaws attacks on web server. Proposed solution combines capabilities of web application firewall and web server log analyzer. Analysis is based on configurable signatures defined by regular expressions. This paper begins with summary of web attacks, followed by detection techniques analysis on web servers, description and justification of selected implementation. In the end are charact...

  18. Electron attachment analyzer

    International Nuclear Information System (INIS)

    Popp, P.; Grosse, H.J.; Leonhardt, J.; Mothes, S.; Oppermann, G.

    1984-01-01

    The invention concerns an electron attachment analyzer for detecting traces of electroaffine substances in electronegative gases, especially in air. The analyzer can be used for monitoring working places, e. g., in operating theatres. The analyzer consists of two electrodes inserted in a base frame of insulating material (quartz or ceramics) and a high-temperature resistant radiation source ( 85 Kr, 3 H, or 63 Ni)

  19. Evaluation by mass fragmentography of metabolic pathways of endogenous and exogenous compounds in eukaryote cell cultures

    International Nuclear Information System (INIS)

    Padieu, P.; Maume, B.F.

    1977-01-01

    Carbon-14 labelled compounds in cell cultures are used to establish the interconnections between different metabolic pathways as well as the competitive action of effectors on these different pathways. Analysis was performed by the GC-MS combination. Identification was carried out by comparison with the mass spectra of d9-TMS, 35 Cl-TMS and 37 Cl-TMS derivatizations of the culture extracts. Examples are given of the metabolic study of hormonal steroids and of safrale, a carcinogenic compound, by differentiated eukaryotic cells in cultures from the rat

  20. Application of Bayesian geostatistics for evaluation of mass discharge uncertainty at contaminated sites

    DEFF Research Database (Denmark)

    Troldborg, Mads; Nowak, Wolfgang; Lange, Ida Vedel

    2012-01-01

    , and (3) uncertain source zone and transport parameters. The method generates conditional realizations of the spatial flow and concentration distribution. An analytical macrodispersive transport solution is employed to simulate the mean concentration distribution, and a geostatistical model of the Box-Cox...... transformed concentration data is used to simulate observed deviations from this mean solution. By combining the flow and concentration realizations, a mass discharge probability distribution is obtained. The method has the advantage of avoiding the heavy computational burden of three-dimensional numerical...

  1. A Bayesian geostatistical approach for evaluating the uncertainty of contaminant mass discharges from point sources

    DEFF Research Database (Denmark)

    Troldborg, Mads; Nowak, Wolfgang; Binning, Philip John

    and the hydraulic gradient across the control plane and are consistent with measurements of both hydraulic conductivity and head at the site. An analytical macro-dispersive transport solution is employed to simulate the mean concentration distribution across the control plane, and a geostatistical model of the Box-Cox...... transformed concentration data is used to simulate observed deviations from this mean solution. By combining the flow and concentration realizations, a mass discharge probability distribution is obtained. Tests show that the decoupled approach is both efficient and able to provide accurate uncertainty...

  2. Critical Evaluation of Native Electrospray Ionization Mass Spectrometry for Fragment-Based Screening.

    Science.gov (United States)

    Göth, Melanie; Badock, Volker; Weiske, Jörg; Pagel, Kevin; Kuropka, Benno

    2017-08-08

    Fragment-based screening presents a promising alternative to high-throughput screening and has gained great attention in recent years. So far, only a few studies have discussed mass spectrometry as a screening technology for fragments. Herein, we report the application of native electrospray ionization mass spectrometry (MS) for screening defined sets of fragments against four different target proteins. Fragments were selected from a primary screening conducted with a thermal shift assay (TSA) and represented different binding categories. Our data indicated that, beside specific complex formation, many fragments show extensive multiple binding and also charge-state shifts. Both of these factors complicate automated data analysis and decrease the attractiveness of native MS as a primary screening tool for fragments. A comparison of the hits identified by native MS and TSA showed good agreement for two of the proteins. Furthermore, we discuss general challenges, including the determination of an optimal fragment concentration and the question of how to rank fragment hits according to their affinity. In conclusion, we consider native MS to be a highly valuable tool for the validation and deeper investigation of promising fragment hits rather than a method for primary screening. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Evaluating Urban Forms for Comparison Studies in the Massing Design Stage

    Directory of Open Access Journals (Sweden)

    Kian Wee Chen

    2017-06-01

    Full Text Available We introduce five performance indicators to facilitate the comparison of urban massing design in the early design stages. The five simple indicators are based on existing studies and cover three main performance areas that are sensitive to urban form changes: solar, ventilation, and connectivity potentials. The first three indicators—the non-solar heated façade to floor area index, daylight façade to floor area index, and photovoltaics envelope to floor area index—measure the solar potential. The frontal area index measures the ventilation potential and the route-directness index measures the connectivity potential. The indicators are simple to use, as they only require urban geometry data for their calculation. We demonstrate the indicators in two case studies; variations in the values of these indicators show that they are sensitive to urban form changes and can be used in comparative studies to identify better performing urban forms among massing designs. We implement the indicators as an open-source Python library, Pyliburo, that designers and researchers can readily access and integrate into their existing design workflows.

  4. Mass Media and Re-Branding Nigeria Project: A Historical Evaluation of a Failed Government Policy

    Directory of Open Access Journals (Sweden)

    Kelechi Johnmary Ani

    2014-03-01

    Full Text Available Mass media exercise extra-ordinary influence on the state and citizenry of every country and the ability of media to facilitate man’s behavioural change through its agenda- setting role makes them central in the re-branding process. The implication became that those politicians who champion the re-branding process tried to win the citizenry’s legitimacy through the media. This paper shows that the major challenges of the re-branding project include the inability of the Nigerian political leadership to re-brand themselves, corruption in every sphere of our national life, national insecurity, advance fee fraud, collapse of the education sector, poverty. It revealed that peace is a multi-dimensional term, which creates new environment for progressive nation building process. The rebranding project finally failed when the protagonist minister went to contest for senatorial election and his successor refused to step into her re-branding project shoes. This work called for the rise of a new government and media that would engage in ethical politics through sound leaders, priming, peace building, ethical education, etc as the roadmap to sustainable peace, security and national re-branding. The paper concluded by showing that it is only a national re-branding that is championed by the masses which can lead the citizenry to the desired goals of being a real Giant of Africa.

  5. Evaluating the contribution of differences in lean mass compartments for resting energy expenditure in African American and Caucasian American children.

    Science.gov (United States)

    Broadney, M M; Shareef, F; Marwitz, S E; Brady, S M; Yanovski, S Z; DeLany, J P; Yanovski, J A

    2018-04-26

    Resting energy expenditure (REE), adjusted for total lean mass (LM), is lower in African American (AA) than Caucasian American (CA) children. Some adult studies suggest that AA-CA differences in lean mass compartments explain this REE difference. Similar data are limited in children. To evaluate differences in compartment-specific lean mass between AA and CA children and examine the individual contributions of high-metabolic rate-at-rest trunk lean mass (TrLM) and low-metabolic-rate-at-rest appendicular lean mass (AppLM) for AA-CA differences in REE. We studied a convenience sample of 594 AA (n = 281) and CA (n = 313) children. REE was measured by using indirect calorimetry; dual-energy X-ray absorptiometry was used to assess body composition. ANCOVAs were performed to examine AA-CA differences in TrLM, AppLM and REE. After accounting for age, sex, height, pubertal development, bone mass and adiposity, REE was evaluated adjusting for total LM (model A) and separately adjusting for TrLM and AppLM (model B). African American children had greater adjusted AppLM (17.8 ± 0.2 [SE] vs. 16.0 ± 0.2 kg, p < 0.001) and lower TrLM (17.2 ± 0.2 vs. 17.7 ± 0.2 kg, p = 0.022) than CA children. REE adjusted for total LM was 77 ± 16 kcal/d lower in AA than CA (p < 0.001). However, after accounting separately for AppLM and TrLM, the discrepancy in REE between the groups declined to 28 ± 19 kcal/d (p = 0.14). In the adjusted model, both TrLM (p < 0.001) and AppLM (p < 0.027) were independently associated with REE. In children, AA-CA differences in REE appear mostly attributable to differences in body composition. Lower REE in AA children is likely due to lower TrLM and greater AppLM. Published 2018. This article is a U.S. Government work and is in the public domain in the USA.

  6. Nuclear power plant analyzer

    International Nuclear Information System (INIS)

    Stritar, A.

    1986-01-01

    The development of Nuclear Power Plant Analyzers in USA is described. There are two different types of Analyzers under development in USA, the forst in Idaho and Los Alamos national Lab, the second in brookhaven National lab. That one is described in detail. The computer hardware and the mathematical models of the reactor vessel thermalhydraulics are described. (author)

  7. Analyzing Peace Pedagogies

    Science.gov (United States)

    Haavelsrud, Magnus; Stenberg, Oddbjorn

    2012-01-01

    Eleven articles on peace education published in the first volume of the Journal of Peace Education are analyzed. This selection comprises peace education programs that have been planned or carried out in different contexts. In analyzing peace pedagogies as proposed in the 11 contributions, we have chosen network analysis as our method--enabling…

  8. Analyzing in the present

    DEFF Research Database (Denmark)

    Revsbæk, Line; Tanggaard, Lene

    2015-01-01

    The article presents a notion of “analyzing in the present” as a source of inspiration in analyzing qualitative research materials. The term emerged from extensive listening to interview recordings during everyday commuting to university campus. Paying attention to the way different parts of vari...

  9. Gearbox vibration diagnostic analyzer

    Science.gov (United States)

    1992-01-01

    This report describes the Gearbox Vibration Diagnostic Analyzer installed in the NASA Lewis Research Center's 500 HP Helicopter Transmission Test Stand to monitor gearbox testing. The vibration of the gearbox is analyzed using diagnostic algorithms to calculate a parameter indicating damaged components.

  10. A Study on evaluation of pitting characteristics of radioactive container materials and development of the program used for analyzing impedance spectrum

    Energy Technology Data Exchange (ETDEWEB)

    Pyun, Su Il; Moon, S. M.; Orr, S. J.; Kim, D. J.; Lee, W. J.; Jeong, I. J.; Shin, H. C.; Han, J. N.; Lee, M. H.; Lee, S. B. [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    1998-01-01

    Pitting corrosion of sensitized 316L stainless steel has been investigated as a function of the degree of sensitization in aqueous NaCl solution with various Cl{sup -} ion concentrations ([Cl{sup -}] = 0.005 (177.25 ppm); 0.01 (354.50 ppm); 0.05 (1772.5 ppm); 0.1 (3545 ppm); 0.5 M (17725 ppm)) at room temperature. The squared rod specimens of 316L stainless steel were thermally annealed at 700 C for various durations (0 h : non-sensitized specimen A; 8 h : moderately sensitized specimen B; 96 h : severely sensitized specimen C). The pitting corrosion resistance of the three kinds of specimens was evaluated by the potentio dynamic anodic polarization method, abrading electrode technique and ac{sup -}impedance spectroscopy. The measured potentiostatic decay current transient obtained just after interrupting the abrading action showed that the repassivation rate of the oxide film on the fresh bare surface of the specimen decreased in the order of specimens A, B and C in the early stage of the film formation. From the results of ac{sup -}impedance spectroscopy, the oxide film resistance R{sub ox} and oxide film capacitance C{sub ox} of specimens B and C in value were evaluated to be lower and higher, respectively, than those of specimen A and the repassivation rate and resistance value of the oxide film on the three kinds could be quantitatively calculated. 10 refs., 8 tabs., 31 figs.(author)

  11. Study on crystalline rock aiming at evaluation method of long-term behavior of rock mass (Joint research)

    International Nuclear Information System (INIS)

    Fukui, Katsunori; Hashiba, Kimihiro; Matsui, Hiroya

    2017-11-01

    It is important to evaluate the stability of a repository for high-level radioactive waste not only during the design, construction and operation phases, but also during the post-closure period, for time frames likely exceeding several millennia or longer. The rock mass around the tunnels could be deformed through time in response to time dependent behavior such as creep and stress relaxation. Therefore, development of methodology to evaluate the past long-term behavior of rock mass is considered to be an issue. In view of above points, this study has been started as a collaboration study with the University of Tokyo from Fiscal Year 2016. In FY 2016, creep testing on Tage tuff was continuously conducted. Existing theory of rate process and stochastic process was modified to be applied to evaluate effects of water, and then the modified theory was validated based on the results of strength and creep tests performed under dry and wet conditions. Furthermore, effects of water contents on stress-strain curves were examined by uniaxial compression testing under various water content conditions. (author)

  12. 'Sink or swim': an evaluation of the clinical characteristics of individuals with high bone mass.

    LENUS (Irish Health Repository)

    Gregson, C L

    2011-04-01

    High bone mineral density on routine dual energy X-ray absorptiometry (DXA) may indicate an underlying skeletal dysplasia. Two hundred fifty-eight individuals with unexplained high bone mass (HBM), 236 relatives (41% with HBM) and 58 spouses were studied. Cases could not float, had mandible enlargement, extra bone, broad frames, larger shoe sizes and increased body mass index (BMI). HBM cases may harbour an underlying genetic disorder. INTRODUCTION: High bone mineral density is a sporadic incidental finding on routine DXA scanning of apparently asymptomatic individuals. Such individuals may have an underlying skeletal dysplasia, as seen in LRP5 mutations. We aimed to characterize unexplained HBM and determine the potential for an underlying skeletal dysplasia. METHODS: Two hundred fifty-eight individuals with unexplained HBM (defined as L1 Z-score ≥ +3.2 plus total hip Z-score ≥ +1.2, or total hip Z-score ≥ +3.2) were recruited from 15 UK centres, by screening 335,115 DXA scans. Unexplained HBM affected 0.181% of DXA scans. Next 236 relatives were recruited of whom 94 (41%) had HBM (defined as L1 Z-score + total hip Z-score ≥ +3.2). Fifty-eight spouses were also recruited together with the unaffected relatives as controls. Phenotypes of cases and controls, obtained from clinical assessment, were compared using random-effects linear and logistic regression models, clustered by family, adjusted for confounders, including age and sex. RESULTS: Individuals with unexplained HBM had an excess of sinking when swimming (7.11 [3.65, 13.84], p < 0.001; adjusted odds ratio with 95% confidence interval shown), mandible enlargement (4.16 [2.34, 7.39], p < 0.001), extra bone at tendon\\/ligament insertions (2.07 [1.13, 3.78], p = 0.018) and broad frame (3.55 [2.12, 5.95], p < 0.001). HBM cases also had a larger shoe size (mean difference 0.4 [0.1, 0.7] UK sizes, p = 0.009) and increased BMI (mean difference 2.2 [1.3, 3.1] kg\\/m(2

  13. Comparison of Macular Integrity Assessment (MAIA ™, MP-3, and the Humphrey Field Analyzer in the Evaluation of the Relationship between the Structure and Function of the Macula.

    Directory of Open Access Journals (Sweden)

    Kazuyuki Hirooka

    Full Text Available This study was conducted in order to compare relationships between the macular visual field (VF mean sensitivity measured by MAIATM (Macular Integrity Assessment, MP-3, or Humphry field analyzer (HFA and the ganglion cell and inner plexiform layer (GCA thicknesses.This cross-sectional study examined 73 glaucoma patients and 19 normal subjects. All subjects underwent measurements for GCA thickness by Cirrus HD-OCT and static threshold perimetry using MAIATM, MP-3, or HFA. VF and OCT in the retinal view were used to examine both the global relationship between the VF sensitivity and GCA thickness, and the superior hemiretina and inferior hemiretina. The relationship between the GCA thickness and macular sensitivity was examined by Spearman correlation analysis.For each instrument, statistically significant macular VF sensitivity (dB and GCA thickness relationships were observed using the decibel scale (R = 0.547-0.687, all P < 0.001. The highest correlation for the global (R = 0.682 and the superior hemiretina (R = 0.594 GCA thickness-VF mean sensitivity was observed by the HFA. The highest correlation for the inferior hemiretina (R = 0.687 GCA thickness-VF mean sensitivity was observed by the MP-3. Among the three VF measurement instruments, however, no significant differences were found for the structure-function relationships.All three VF measurement instruments found similar structure-function relationships in the central VF.

  14. Evaluating statistical and clinical significance of intervention effects in single-case experimental designs: an SPSS method to analyze univariate data.

    Science.gov (United States)

    Maric, Marija; de Haan, Else; Hogendoorn, Sanne M; Wolters, Lidewij H; Huizenga, Hilde M

    2015-03-01

    Single-case experimental designs are useful methods in clinical research practice to investigate individual client progress. Their proliferation might have been hampered by methodological challenges such as the difficulty applying existing statistical procedures. In this article, we describe a data-analytic method to analyze univariate (i.e., one symptom) single-case data using the common package SPSS. This method can help the clinical researcher to investigate whether an intervention works as compared with a baseline period or another intervention type, and to determine whether symptom improvement is clinically significant. First, we describe the statistical method in a conceptual way and show how it can be implemented in SPSS. Simulation studies were performed to determine the number of observation points required per intervention phase. Second, to illustrate this method and its implications, we present a case study of an adolescent with anxiety disorders treated with cognitive-behavioral therapy techniques in an outpatient psychotherapy clinic, whose symptoms were regularly assessed before each session. We provide a description of the data analyses and results of this case study. Finally, we discuss the advantages and shortcomings of the proposed method. Copyright © 2014. Published by Elsevier Ltd.

  15. Evaluation of co-pyrolysis petrochemical wastewater sludge with lignite in a thermogravimetric analyzer and a packed-bed reactor: Pyrolysis characteristics, kinetics, and products analysis.

    Science.gov (United States)

    Mu, Lin; Chen, Jianbiao; Yao, Pikai; Zhou, Dapeng; Zhao, Liang; Yin, Hongchao

    2016-12-01

    Co-pyrolysis characteristics of petrochemical wastewater sludge and Huolinhe lignite were investigated using thermogravimetric analyzer and packed-bed reactor coupled with Fourier transform infrared spectrometer and gas chromatography. The pyrolysis characteristics of the blends at various sludge blending ratios were compared with those of the individual materials. Thermogravimetric experiments showed that the interactions between the blends were beneficial to generate more residues. In packed-bed reactor, synergetic effects promoted the release of gas products and left less liquid and solid products than those calculated by additive manner. Fourier transform infrared spectrometer analysis showed that main functional groups in chars gradually disappeared with pyrolysis temperatures increasing, and H 2 O, CH 4 , CO, and CO 2 appeared in volatiles during pyrolysis. Gas compositions analysis indicated that, the yields of H 2 and CO clearly increased as the pyrolysis temperature and sludge blending ratio increasing, while the changes of CH 4 and CO 2 yields were relatively complex. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Evaluation in the resonance range of nuclei with a mass number above 220

    International Nuclear Information System (INIS)

    Ribon, P.

    1970-01-01

    The author discusses the problems posed by the evaluation of neutron data for fissile or fertile nuclei in the range of resolved or unresolved resonances. It appears to take several years until the data of an experiment are used by the reactor physicists. If one wants to have recent data at one's disposal, one cannot have recourse to evaluated-data libraries. Moreover, the existing parameter sets are only fragmentary. A new evaluation is, therefore, necessary for nearly all of these nuclei, but it cannot be based upon different parameter sets; these are indeed contradictory, and the evaluator will have to go back to the original data. The author shows for the set of σ f of 235 U, that a careful comparison of the data shows up unsuspected local defects. Some examples illustrate the deviation between analyses carried out by different methods and between the results on the established divergences. The parameters or cross-sections are far from being known with the precision one would desire. This fact gives rise to anomalies in the interpretation of data necessary for understanding and simulation in the range of unresolved resonances. But the introduction of concepts connected with sub-threshold fission noticeably furthers this understanding. Therefore a comparison of the methods of analysis must be made in more and more accurate measurements (evaluation and correction of systematic errors). (author) [fr

  17. Computer-aided detection system for masses in automated whole breast ultrasonography: development and evaluation of the effectiveness

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeoung Hyun [Dept. of Radiology, Ewha Womans University Mokdong Hospital, Ewha Womans University School of Medicine, Seoul (Korea, Republic of); Cha, Joo Hee; Kim, Nam Kug; Chang, Young Jun; Kim, Hak Hee [Dept. of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Ko, Myung Su [Health Screening and Promotion Center, Asan Medical Center, Seoul (Korea, Republic of); Choi, Young Wook [Korea Electrotechnology Research Institute, Ansan (Korea, Republic of)

    2014-04-15

    The aim of this study was to evaluate the performance of a proposed computer-aided detection (CAD) system in automated breast ultrasonography (ABUS). Eighty-nine two-dimensional images (20 cysts, 42 benign lesions, and 27 malignant lesions) were obtained from 47 patients who underwent ABUS (ACUSON S2000). After boundary detection and removal, we detected mass candidates by using the proposed adjusted Otsu's threshold; the threshold was adaptive to the variations of pixel intensities in an image. Then, the detected candidates were segmented. Features of the segmented objects were extracted and used for training/testing in the classification. In our study, a support vector machine classifier was adopted. Eighteen features were used to determine whether the candidates were true lesions or not. A five-fold cross validation was repeated 20 times for the performance evaluation. The sensitivity and the false positive rate per image were calculated, and the classification accuracy was evaluated for each feature. In the classification step, the sensitivity of the proposed CAD system was 82.67% (SD, 0.02%). The false positive rate was 0.26 per image. In the detection/segmentation step, the sensitivities for benign and malignant mass detection were 90.47% (38/42) and 92.59% (25/27), respectively. In the five-fold cross-validation, the standard deviation of pixel intensities for the mass candidates was the most frequently selected feature, followed by the vertical position of the centroids. In the univariate analysis, each feature had 50% or higher accuracy. The proposed CAD system can be used for lesion detection in ABUS and may be useful in improving the screening efficiency.

  18. Cs+ ion source for secondary ion mass spectrometry

    International Nuclear Information System (INIS)

    Bentz, B.L.; Weiss, H.; Liebl, H.

    1981-12-01

    Various types of cesium ionization sources currently used in secondary ion mass spectrometry are briefly reviewed, followed by a description of the design and performance of a novel, thermal surface ionization Cs + source developed in this laboratory. The source was evaluated for secondary ion mass spectrometry applications using the COALA ion microprobe mass analyzer. (orig.)

  19. Evaluation of correction in shaping body mass women first adulthood with different personal features

    Directory of Open Access Journals (Sweden)

    S.A. Smaylova

    2013-06-01

    Full Text Available Assessed the effectiveness of training method of the "Shaping Classic" on the catabolic program correction of body weight the first mature age women with different personality characteristics. The study involved 20 women aged 26 - 30 years with a body mass index above average and high. Conducted anthropometric measurements. Used physiological tests, step test Prohorovtseva, engine test, psychodiagnostic methods. The efficiency of the program in reducing total body weight and body fat. The positive impact of the program on the functional state of the cardiovascular system and the musculoskeletal system is shown. Found that particular dispositions eating and self-esteem of women may reduce the level of impact of training. It is revealed that these features contribute to devaluing recommendations coach and weaken the motivation to train.

  20. Multi-centre evaluation of mass spectrometric identification of anaerobic bacteria using the VITEK® MS system.

    Science.gov (United States)

    Garner, O; Mochon, A; Branda, J; Burnham, C-A; Bythrow, M; Ferraro, M; Ginocchio, C; Jennemann, R; Manji, R; Procop, G W; Richter, S; Rychert, J; Sercia, L; Westblade, L; Lewinski, M

    2014-04-01

    Accurate and timely identification of anaerobic bacteria is critical to successful treatment. Classic phenotypic methods for identification require long turnaround times and can exhibit poor species level identification. Matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS) is an identification method that can provide rapid identification of anaerobes. We present a multi-centre study assessing the clinical performance of the VITEK(®) MS in the identification of anaerobic bacteria. Five different test sites analysed a collection of 651 unique anaerobic isolates comprising 11 different genera. Multiple species were included for several of the genera. Briefly, anaerobic isolates were applied directly to a well of a target plate. Matrix solution (α-cyano-4-hydroxycinnamic acid) was added and allowed to dry. Mass spectra results were generated with the VITEK(®) MS, and the comparative spectral analysis and organism identification were determined using the VITEK(®) MS database 2.0. Results were confirmed by 16S rRNA gene sequencing. Of the 651 isolates analysed, 91.2% (594/651) exhibited the correct species identification. An additional eight isolates were correctly identified to genus level, raising the rate of identification to 92.5%. Genus-level identification consisted of Actinomyces, Bacteroides and Prevotella species. Fusobacterium nucleatum, Actinomyces neuii and Bacteroides uniformis were notable for an increased percentage of no-identification results compared with the other anaerobes tested. VITEK(®) MS identification of clinically relevant anaerobes is highly accurate and represents a dramatic improvement over other phenotypic methods in accuracy and turnaround time. © 2013 The Authors Clinical Microbiology and Infection © 2013 European Society of Clinical Microbiology and Infectious Diseases.

  1. Prospective evaluation of EUS-guided fine needle biopsy in pancreatic mass lesions

    DEFF Research Database (Denmark)

    Larsen, M H; Fristrup, C W; Detlefsen, S

    2018-01-01

    Background and study aim : Due to the scarcity of specific data on endoscopic ultrasound (EUS)-guided fine-needle biopsies (SharkCore) FNB in the evaluation of pancreatic lesions, we performed a prospective study of the diagnostic performance of EUS SharkCore FNB in patients with pancreatic lesions...

  2. Performance evaluation of indigenous thermal ionization mass spectrometer for determination of 235U/238U atom ratios

    International Nuclear Information System (INIS)

    Alamelu, D.; Parab, A.R.; Sasi Bhushan, K.; Shah, Raju V.; Jagdish Kumar, S.; Rao, Radhika M.; Aggarwal, S.K.; Bhatia, R.K.; Yadav, V.K.; Sharma, Madhavi P.; Tulsyan, Puneet; Chavda, Pradip; Sriniwasan, P.

    2014-07-01

    A magnetic sector based Thermal Ionization Mass Spectrometer (TIMS) designed and developed at Technical Physics Division, B.A.R.C., was evaluated for its performance for the determination of 235 U/ 238 U atom ratios in uranium samples. This consisted of evaluating the precision and accuracy on the 235 U/ 238 U atom ratios in various isotopic reference materials as well as indigenously generated uranium samples. The results obtained by the indigenous TIMS were also compared with those obtained using a commercially available TIMS system. The internal and external precision were found to be around 0.1% for determining 235 U/ 238 U atom ratios close to those of natural uranium ( i.e. 0.00730). (author)

  3. Evaluation of mass transport property using natural uranium-series and thorium-series nuclides in the Toki Granite

    International Nuclear Information System (INIS)

    Hama, Katsuhiro

    2016-07-01

    The Mizunami Underground Research Laboratory (MIU) project is being pursued by the Japan Atomic Energy Agency (JAEA) to enhance the reliability of relevant disposal technologies through investigations of the deep geological environment within the host crystalline rock at Mizunami City in Gifu Prefecture, central Japan. The project proceeds in three overlapping phases, 'Phase I: Surface-based investigation Phase', 'Phase II: Construction Phase' and 'Phase III: Operation Phase'. As a part of the Phase III investigation, the mass transport property has been evaluated by using natural uranium-series and thorium-series nuclides in the Toki Granite. In this report, the compilation of existing data and preliminary evaluation was carried out. (author)

  4. Evaluating 3-D and 1-D mathematical models for mass transport in heterogeneous biofilms

    DEFF Research Database (Denmark)

    Morgenroth, Eberhard Friedrich; Eberl, H.; van Loosdrecht, M. C. M.

    2000-01-01

    Results from a three dimensional model for heterogeneous biofilms including the numerical solution of hydrodynamics were compared to simplified one dimensional models. A one dimensional model with a variable diffusion coefficient over the thickness of the biofilm was well suited to approximate...... average concentration profiles of three dimensional simulations of rough biofilms. A new compartmentalized one dimensional model is presented that is then used to evaluate effects of pores and channels on microbial competition in heterogeneous biofilms. Surface and pore regions of the biofilm are modeled...... using separate compartments coupled by a convective link. Local concentration profiles from the three dimensional simulations could be adequately reproduced using the compartmentalized one dimensional model. The compartmentalized one dimensional model was then used to evaluate bacterial competition...

  5. Population-based evaluation of the 'LiveLighter' healthy weight and lifestyle mass media campaign.

    Science.gov (United States)

    Morley, B; Niven, P; Dixon, H; Swanson, M; Szybiak, M; Shilton, T; Pratt, I S; Slevin, T; Hill, D; Wakefield, M

    2016-04-01

    The Western Australian (WA) 'LiveLighter' (LL) mass media campaign ran during June-August and September-October 2012. The principal campaign ad graphically depicts visceral fat of an overweight individual ('why' change message), whereas supporting ads demonstrate simple changes to increase activity and eat healthier ('how' to change message). Cross-sectional surveys among population samples aged 25-49 were undertaken pre-campaign (N= 2012) and following the two media waves (N= 2005 and N= 2009) in the intervention (WA) and comparison state (Victoria) to estimate the population impact of LL. Campaign awareness was 54% after the first media wave and overweight adults were more likely to recall LL and perceive it as personally relevant. Recall was also higher among parents, but equal between socio-economic groups. The 'why' message about health-harms of overweight rated higher than 'how' messages about lifestyle change, on perceived message effectiveness which is predictive of health-related intention and behaviour change. State-by-time interactions showed population-level increases in self-referent thoughts about the health-harms of overweight (P stereotypes of overweight individuals did not increase after LL aired. LL was associated with some population-level improvements in proximal and intermediate markers of campaign impact. However, sustained campaign activity will be needed to impact behaviour. © The Author 2016. Published by Oxford University Press.

  6. Electrostatic micromanipulation of a conductive particle by a single probe with consideration of an error in the evaluated mass

    International Nuclear Information System (INIS)

    Sawai, Kenji; Saito, Shigeki

    2010-01-01

    Recently, micromanipulation techniques for handling a conductive microparticle have been in demand. Electrostatic micromanipulation with a single probe is a promising technique for such manipulation. While the feasibility of the technique has been proved experimentally, the success rate of manipulation was 25%, and further improvements are required. To enhance the success rate and realize highly reliable electrostatic micromanipulation, this paper proposes an improved design of a voltage sequence which is applied to deposit a microparticle onto a substrate plate. It was found through investigation that the error in the evaluated mass of a microparticle must be considered in order to improve the success rate of the manipulation. Behavior of a microparticle during the electrostatic micromanipulation is calculated by a boundary element method, and the influence of error is discussed. An improved design of the applied voltage sequence that can tolerate an error in the evaluated mass is described. Moreover, the effectiveness of the newly designed voltage sequence in the electrostatic micromanipulation is experimentally shown.

  7. Analytical performance evaluation of the Elecsys® Cyclosporine and Elecsys® Tacrolimus assays on the cobas e411 analyzer

    Directory of Open Access Journals (Sweden)

    Maki Sasano

    2017-08-01

    Full Text Available Background: Cyclosporine (CsA and tacrolimus (TAC are immunosuppressant drugs that are often used to treat autoimmune diseases and as transplantation therapy; therefore, their concentrations need to be monitored carefully. We herein evaluated the analytical performance of the Elecsys® Cyclosporine and Elecsys® Tacrolimus assay kits, which have been newly developed to measure CsA and TAC concentrations in the whole blood. Methods: We used residual whole blood samples from autoimmune disease and transplantation patients who were being treated with CsA or TAC. CsA concentrations were measured using an affinity chrome-mediated immunoassay (ACMIA and an electrochemiluminescence immunoassay (ECLIA. TAC concentrations were measured using a chemiluminescence immunoassay (CLIA and ECLIA. We investigated assay precision, linearity, lower limit of quantitation (LOQ, stability of calibration, influence of interference substances and the hematocrit, correlation of ACMIA with ECLIA, and correlation of CLIA with ECLIA. Results: Within-assay coefficients of variation were 1.8−3.6% (CsA: 94−1238 ng/mL and 2.9−3.9% (TAC: 2.1−17.8 ng/mL, whereas day-to-day coefficients of variation ranged between 3.0−4.1% (CsA and 2.8−3.9% (TAC. The limits of quantitation were defined as the concentration at which the CV was approximately 10%. Each lower LOQ obtained was 16 ng/mL (CsA, and 0.95 ng/mL (TAC. CsA and TAC calibrations were stable for at least 21 days. Neither the presence of conjugated bilirubin, unconjugated bilirubin, chyle, and rheumatoid factor nor the hematocrit affected these assays. A method comparison using a standardized major axis regression analysis of ACMIA and ECLIA was r=0.995, y=0.924x −1.175, n=200 (CsA, while that of CLIA and ECLIA was r=0.994, y=1.080x −0.197, n=200 (TAC. Conclusions: The analytical performances of the Elecsys® Cyclosporine and Elecsys®Tacrolimus assays were acceptable

  8. Evaluation of the environmental and social sustainability policy of a mass tourism resort: A narrative account

    Directory of Open Access Journals (Sweden)

    Isabel Swart

    2012-09-01

    Full Text Available The recordation of the life stories of individuals residing in the community of Ledig, who have been dependent on the Sun City Resort situated in the Pilanesberg area in the North West Province of South Africa for their quality of life for more than 20 years, provided the basis for the evaluation of the environmental and social sustainability of this micro-cosmos on a multidisciplinary level. This study focused on the hermeneutical arch of narrative theory within the framework of human geography and sustainability science. The natural environment was evaluated for the role it plays in the sustainability of the livelihoods of the Ledig community members as well as the institutional life of the Sun City Resort. The results of this study suggested that the environmental policy for the Sun City Resort, formalised in 2004, has been guiding the Sun City Resort to contribute positively to the sustainability of the area. The study also demonstrated that a focus on the next generation of potential employees and the environmental education of all the communities were crucial to ensure the resilience of the social and ecological capacity of the area.

  9. Extraction spectrophotometric analyzer

    International Nuclear Information System (INIS)

    Batik, J.; Vitha, F.

    1985-01-01

    Automation is discussed of extraction spectrophotometric determination of uranium in a solution. Uranium is extracted from accompanying elements in an HCl medium with a solution of tributyl phosphate in benzene. The determination is performed by measuring absorbance at 655 nm in a single-phase ethanol-water-benzene-tributyl phosphate medium. The design is described of an analyzer consisting of an analytical unit and a control unit. The analyzer performance promises increased productivity of labour, improved operating and hygiene conditions, and mainly more accurate results of analyses. (J.C.)

  10. Evaluation of common mental disorders in women with polycystic ovary syndrome and its relationship with body mass index.

    Science.gov (United States)

    Rodrigues, Cristine Eliane Gomes; Ferreira, Luana de Lima; Jansen, Karen; Lopez, Mariane Ricardo Acosta; Drews Júnior, Cláudio Raul; Souza, Luciano Dias de Mattos

    2012-10-01

    To evaluate the prevalence of common mental disorders in women diagnosed with polycystic ovary syndrome as compared with paired controls without this syndrome. Cross-sectional study with a Control Group examining women between the ages of 18 and 30 who did not use antidepressants and who sought the Gynecology Service of the researched sites. For every woman diagnosed with the polycystic ovary syndrome, another with the same age, educational status and presence or absence of sexual partners was sought without this diagnosis. In total, 166 patients agreed to participate, consisting of 95 diagnosed with polycystic ovary syndrome and 71 in the Control Group. The diagnosis of polycystic ovary syndrome was made by the presence of two from three criteria: oligomenorrhea or amenorrhea, clinical or biochemical hyperandrogenism and polycystic ovaries on transvaginal ultrasound, following exclusion of patients with Cushing's syndrome, congenital adrenal hyperplasia, and androgen-secreting tumors. Weight and height were measured to calculate the body mass index. The Self-Reporting Questionnaire, which evaluated 20 items, was used as an indicator of common mental disorders. A χ² analysis stratified by the category of body mass index was used to compare the prevalence of common mental disorders, between the groups of women with and without the polycystic ovary syndrome. There were no significant differences in age, education, presence of sexual partners, ethnicity, socioeconomic status, use of psychiatric medication, and search for consultation in mental health between the studied groups. The prevalence of obese women with indications of common mental disorders was significantly higher in women with polycystic ovary syndrome than in the Control Group. In the group with healthy body mass index, the incidence of common mental disorders was statistically significant different between women with polycystic ovary syndrome and normal controls (p=0.008). Women with diagnosis of this

  11. Evaluation of the incorporation of Cariri stone in masses of ceramics tiles

    International Nuclear Information System (INIS)

    Barroso, M.D.B.; Pereira, F.M.; Santos, I.S.; Melo, P.S.; Vieira, F.M.; Marinho, R.M.M.

    2016-01-01

    Mining and laminated limestone processing operations called Cariri stone, located in the Sedimentary Basin of Araripe, in the southern state is an important economic sector of the State of Ceara. As a result of this operation produces a large amount of waste. This study aims to evaluate the effect of incorporation of this residue in the red ceramic as an alternative raw material for the production of tiles. The compositions were formulated and prepared specimens with 0% content 5%, 10%, 12%, 15% and 20% by weight of residue. The determination of physical and mechanical properties such as loss on ignition, linear shrinkage, water absorption and flexural strength was carried out on specimens uniaxially pressed at 27 MPa and sintered at 900 ° C. The results indicated that for a content to 10% by weight of waste there is an improvement of physical and mechanical properties. On the other hand higher amounts of residue compromise its mechanical properties. (author)

  12. Americal options analyzed differently

    NARCIS (Netherlands)

    Nieuwenhuis, J.W.

    2003-01-01

    In this note we analyze in a discrete-time context and with a finite outcome space American options starting with the idea that every tradable should be a martingale under a certain measure. We believe that in this way American options become more understandable to people with a good working

  13. Analyzing Political Television Advertisements.

    Science.gov (United States)

    Burson, George

    1992-01-01

    Presents a lesson plan to help students understand that political advertisements often mislead, lie, or appeal to emotion. Suggests that the lesson will enable students to examine political advertisements analytically. Includes a worksheet to be used by students to analyze individual political advertisements. (DK)

  14. Centrifugal analyzer development

    International Nuclear Information System (INIS)

    Burtis, C.A.; Bauer, M.L.; Bostick, W.D.

    1976-01-01

    The development of the centrifuge fast analyzer (CFA) is reviewed. The development of a miniature CFA with computer data analysis is reported and applications for automated diagnostic chemical and hematological assays are discussed. A portable CFA system with microprocessor was adapted for field assays of air and water samples for environmental pollutants, including ammonia, nitrates, nitrites, phosphates, sulfates, and silica. 83 references

  15. Mass concentration coupled with mass loading rate for evaluating PM_2_._5 pollution status in the atmosphere: A case study based on dairy barns

    International Nuclear Information System (INIS)

    Joo, HungSoo; Park, Kihong; Lee, Kwangyul; Ndegwa, Pius M.

    2015-01-01

    This study investigated particulate matter (PM) loading rates and concentrations in ambient air from naturally ventilated dairy barns and also the influences of pertinent meteorological factors, traffic, and animal activities on mass loading rates and mass concentrations. Generally, relationships between PM_2_._5 concentration and these parameters were significantly poorer than those between the PM loading rate and the same parameters. Although ambient air PM_2_._5 loading rates correlated well with PM_2_._5 emission rates, ambient air PM_2_._5 concentrations correlated poorly with PM_2_._5 concentrations in the barns. A comprehensive assessment of PM_2_._5 pollution in ambient air, therefore, requires both mass concentrations and mass loading rates. Emissions of PM_2_._5 correlated strongly and positively with wind speed, temperature, and solar radiation (R"2 = 0.84 to 0.99) and strongly but negatively with relative humidity (R"2 = 0.93). Animal activity exhibited only moderate effect on PM_2_._5 emissions, while traffic activity did not significantly affect PM_2_._5 emissions. - Highlights: • Sink PM_2_._5 loading rates correlate well with source PM_2_._5 emission rates. • Sink PM_2_._5 concentrations correlate poorly with source PM_2_._5 concentrations. • Mass loading rate complements mass concentration in appraising sink PM_2_._5 status. • PM_2_._5 emissions is dependent on wind speed, temp, solar strength, and RH. • Cow traffic activity affects PM_2_._5 emissions, while traffic activity does not. - Both PM mass loading rate and concentrations are required for comprehensive assessment of pollution potential of PM released into the atmosphere.

  16. Evaluation of The Value of Core Needle Biopsy in The Diagnosis of a Breast Mass

    Directory of Open Access Journals (Sweden)

    Asieh Sadat Fattahi

    2016-06-01

    Full Text Available Background: Core needle biopsy (CNB with histological findings is regarded as one of the most important diagnostic measures that make preoperative assessment and planning for appropriate treatment possible. The aim of this study was to determine the sensitivity and specificity of core biopsy results in our patients with benign and malignant breast lumps, especially for borderline breast lesions, by using a classification method.Methods: In this study, 116 patients who were referred to the Surgery Clinic of Ghaem Hospital, Mashhad University of Medical Sciences, Mashhad, Iran with breast lump and underwent diagnostic procedures such as mammography and ultrasound were selected. Core needle biopsy (Tru-cut #14 or 16 was performed. After that, excisional biopsy was done. The benign, malignant and unspecified samples obtained by core needle biopsy were evaluated with the samples of the surgical and pathological findings. Then, false positive, false negative, sensitivity, specificity, and diagnostic accuracy of the core needle biopsy method were calculated. Also, the National Health Service Breast Screening Program (NHSBSP classification was employed.Results: The mean age of the participants in this study was 39±13.13 years and the mean tumor size was 2.7 cm. An average of 3.35 biopsies was taken from all patients. Most of the pathology samples taken from CNB and excisional biopsy were compatible with invasive ductal carcinoma. Of the B type classifications, B5 was the most frequent in both methods. Borderline lesions B3 and B4 had a change in their category after surgery. About 2.5% of the samples in core biopsy were inadequate. Skin bruising was the most common core biopsy complication reported. While, the most common complication of excisional biopsy was hematoma. Accuracy, sensitivity, specificity, positive and negative predictive values of the core needle biopsy procedure compared with excisional biopsy was 95.5%, 92.6%, 100%, 100%, and 91

  17. [MALDI-TOF mass spectrometry: Evaluation of the preanalytical phase for identification of molds].

    Science.gov (United States)

    Maldonado, Ivana; García Ramírez, Dolores; Striebeck, Pablo; Lafage, Marcelo; Fernández Canigia, Liliana

    In order to optimize the identification of molds with MALDI-TOF MS, three protein extraction-methodologies were evaluated against 44 isolates: water extraction (WE), zirconium extraction (ZE) and the provider's recommended method (PRM). Two data bases were compared, Bruker (BK) and Bruker+National Institutes of Health. Considering both databases, results were respectively as follows: correct identification (CI) at gender level, 10 and 16 by WE; 27 and 32 by ZE and 18 and 23 by PRM; CI at species level, 5 and 7 by WE; 17 and 20 by ZE and 11 and 14 by PRM; non-reliable identification, 18 and 12 by WE; 9 and 4 by ZE and by PRM. No peaks were observed in 16 by WE, 8 by ZE and 17 by PRM. ZE showed the best perfomance (p<0.05). Copyright © 2016 Asociación Argentina de Microbiología. Publicado por Elsevier España, S.L.U. All rights reserved.

  18. Investigation on location-dependent detectability of a small mass for digital breast tomosynthesis evaluation

    Science.gov (United States)

    Lee, Changwoo; Baek, Jongduk; Park, Subok

    2016-03-01

    Digital breast tomosynthesis (DBT) is an emerging imaging modality for improved breast cancer detection and diagnosis [1-5]. Numerous efforts have been made to find quantitative metrics associated with mammographic image quality assessment, such as the exponent β of anatomical noise power spectrum, glandularity, contrast noise ratio, etc. [6-8]. In addition, with the use of Fourier-domain detectability for a task-based assessment of DBT, a stationarity assumption on reconstructed image statistics was often made [9-11], resulting in the use of multiple regions-of-interest (ROIs) from different locations in order to increase sample size. While all these metrics provide some information on mammographic image characteristics and signal detection, the relationship between these metrics and detectability in DBT evaluation has not been fully understood. In this work, we investigated spatial-domain detectability trends and levels as a function of the number of slices Ns at three different ROI locations on the same image slice, where background statistics differ in terms of the aforementioned metrics. Detectabilities for the three ROI locations were calculated using multi-slice channelized Hotelling observers with 2D/3D Laguerre-Gauss channels. Our simulation results show that detectability levels and trends as a function of Ns vary across these three ROI locations. They also show that the exponent β, mean glandularity, and mean attenuation coefficient vary across the three ROI locations but they do not necessarily predict the ranking of detectability levels and trends across these ROI locations.

  19. Evaluate the accuracy of the numerical solution of hydrogeological problems of mass transfer

    Directory of Open Access Journals (Sweden)

    Yevhrashkina G.P.

    2014-12-01

    Full Text Available In the hydrogeological task on quantifying pollution of aquifers the error are starting add up with moment organization of regime observation network as a source of information on the pollution of groundwater in order to evaluate migration options for future prognosis calculations. Optimum element regime observation network should consist of three drill holes on the groundwater flow at equal distances from one another and transversely to the flow of the three drill holes, and at equal distances. If the target of observation drill holes coincides with the stream line on which will then be decided by direct migration task, the error will be minimal. The theoretical basis and results of numerical experiments to assess the accuracy of direct predictive tasks planned migration of groundwater in the area of full water saturation. For the vadose zone, we consider problems of vertical salt transport moisture. All studies were performed by comparing the results of fundamental and approximate solutions in a wide range of characteristics of the processes, which are discussed in relation to ecological and hydrogeological conditions of mining regions on the example of the Western Donbass.

  20. Micronucleus test for radiation biodosimetry in mass casualty events: Evaluation of visual and automated scoring

    Energy Technology Data Exchange (ETDEWEB)

    Bolognesi, Claudia, E-mail: claudia.bolognesi@istge.i [Environmental Carcinogenesis Unit, National Cancer Research Institute, Largo R. Benzi 10, 16132 Genoa (Italy); Balia, Cristina; Roggieri, Paola [Environmental Carcinogenesis Unit, National Cancer Research Institute, Largo R. Benzi 10, 16132 Genoa (Italy); Cardinale, Francesco [Clinical Epidemiology Unit, National Cancer Research Institute, Largo R. Benzi 10, 16132 Genoa (Italy); Department of Health Sciences, University of Genoa, Genoa (Italy); Bruzzi, Paolo [Clinical Epidemiology Unit, National Cancer Research Institute, Largo R. Benzi 10, 16132 Genoa (Italy); Sorcinelli, Francesca [Environmental Carcinogenesis Unit, National Cancer Research Institute, Largo R. Benzi 10, 16132 Genoa (Italy); Laboratory of Genetics, Histology and Molecular Biology Section, Army Medical and Veterinary, Research Center, Via Santo Stefano Rotondo 4, 00184 Roma (Italy); Lista, Florigio [Laboratory of Genetics, Histology and Molecular Biology Section, Army Medical and Veterinary, Research Center, Via Santo Stefano Rotondo 4, 00184 Roma (Italy); D' Amelio, Raffaele [Sapienza, Universita di Roma II Facolta di Medicina e Chirurgia and Ministero della Difesa, Direzione Generale Sanita Militare (Italy); Righi, Enzo [Frascati National Laboratories, National Institute of Nuclear Physics, Via Enrico Fermi 40, 00044 Frascati, Rome (Italy)

    2011-02-15

    In the case of a large-scale nuclear or radiological incidents a reliable estimate of dose is an essential tool for providing timely assessment of radiation exposure and for making life-saving medical decisions. Cytogenetics is considered as the 'gold standard' for biodosimetry. The dicentric analysis (DA) represents the most specific cytogenetic bioassay. The micronucleus test (MN) applied in interphase in peripheral lymphocytes is an alternative and simpler approach. A dose-effect calibration curve for the MN frequency in peripheral lymphocytes from 27 adult donors was established after in vitro irradiation at a dose range 0.15-8 Gy of {sup 137}Cs gamma rays (dose rate 6 Gy min{sup -1}). Dose prediction by visual scoring in a dose-blinded study (0.15-4.0 Gy) revealed a high level of accuracy (R = 0.89). The scoring of MN is time consuming and requires adequate skills and expertise. Automated image analysis is a feasible approach allowing to reduce the time and to increase the accuracy of the dose estimation decreasing the variability due to subjective evaluation. A good correlation (R = 0.705) between visual and automated scoring with visual correction was observed over the dose range 0-2 Gy. Almost perfect discrimination power for exposure to 1-2 Gy, and a satisfactory power for 0.6 Gy were detected. This threshold level can be considered sufficient for identification of sub lethally exposed individuals by automated CBMN assay.

  1. One Sample, One Shot - Evaluation of sample preparation protocols for the mass spectrometric proteome analysis of human bile fluid without extensive fractionation.

    Science.gov (United States)

    Megger, Dominik A; Padden, Juliet; Rosowski, Kristin; Uszkoreit, Julian; Bracht, Thilo; Eisenacher, Martin; Gerges, Christian; Neuhaus, Horst; Schumacher, Brigitte; Schlaak, Jörg F; Sitek, Barbara

    2017-02-10

    The proteome analysis of bile fluid represents a promising strategy to identify biomarker candidates for various diseases of the hepatobiliary system. However, to obtain substantive results in biomarker discovery studies large patient cohorts necessarily need to be analyzed. Consequently, this would lead to an unmanageable number of samples to be analyzed if sample preparation protocols with extensive fractionation methods are applied. Hence, the performance of simple workflows allowing for "one sample, one shot" experiments have been evaluated in this study. In detail, sixteen different protocols implying modifications at the stages of desalting, delipidation, deglycosylation and tryptic digestion have been examined. Each method has been individually evaluated regarding various performance criteria and comparative analyses have been conducted to uncover possible complementarities. Here, the best performance in terms of proteome coverage has been assessed for a combination of acetone precipitation with in-gel digestion. Finally, a mapping of all obtained protein identifications with putative biomarkers for hepatocellular carcinoma (HCC) and cholangiocellular carcinoma (CCC) revealed several proteins easily detectable in bile fluid. These results can build the basis for future studies with large and well-defined patient cohorts in a more disease-related context. Human bile fluid is a proximal body fluid and supposed to be a potential source of disease markers. However, due to its biochemical composition, the proteome analysis of bile fluid still represents a challenging task and is therefore mostly conducted using extensive fractionation procedures. This in turn leads to a high number of mass spectrometric measurements for one biological sample. Considering the fact that in order to overcome the biological variability a high number of biological samples needs to be analyzed in biomarker discovery studies, this leads to the dilemma of an unmanageable number of

  2. Application and evaluation of the mass spectrometric isotope dilution technique in the determination of rare earths in geological materials

    International Nuclear Information System (INIS)

    Moraes, N.M.P. de.

    1988-01-01

    Establishment of the experimental procedures employed in the rare earth element determination of geological samples by mass spectrometric isotope dilution analysis is discussed in the present work. The procedures involve preparation and calibration of the isotope tracers isotope dilution, dissolution in a teflon pressure vessel, chemical separation and isotope analysis using a fully automated Micromass VG ISOTOPES model 354 thermal ionization mass spectrometer. For the initial chemical separation of total rare earths the cationic resin was employed and HC1 and HNO 3 acids as eluents. In the second step rare earths elements were separated into individual (La, Ce and Nd) and subgroups (Sm-Eu-Gd, Yb-Er-Dy) fractions using the same cationic resin and α-HIBA as eluent. Nine elements La, Ce, Nd, Sm, Eu, Gd, Dy, Er and Yb are determined by this method in the ''United States Geological Survey'' (USGS) standard samples GSP-1, AGV-1 and G-2, with an overall precision of +- 1 to 2% and an accuracy of 5%. The concentration of rare earth element determined in the standard sample PCC-1 showed that the total analytical blanks are in submicrogram levels. The concentration of rare earth elements in the same USGS standard samples were also determined by Instrumental neutron activation analysis, neutron activation analysis with chemical separation before irradiation and inductively coupled argon plasma spectroscopy. The chemical procedures employed for these methods are the same as that used for mass spectrometric isotope dilution. Based on the results obtained, each method was evaluated pointing out their merits and defects. The study clearly showed that the chemical procedure employed for all these techniques was satisfactory. (author) [pt

  3. Validated ultra-performance liquid chromatography-tandem mass spectrometry method for analyzing LSD, iso-LSD, nor-LSD, and O-H-LSD in blood and urine.

    Science.gov (United States)

    Chung, Angela; Hudson, John; McKay, Gordon

    2009-06-01

    The Royal Canadian Mounted Police Forensic Science and Identification Services was looking for a confirmatory method for lysergic acid diethylamide (LSD). As a result, an ultra-performance liquid chromatography-tandem mass spectrometry method was validated for the confirmation and quantitation of LSD, iso-LSD, N-demethyl-LSD (nor-LSD), and 2-oxo-3-hydroxy-LSD (O-H-LSD). Relative retention time and ion ratios were used as identification parameters. Limits of detection (LOD) in blood were 5 pg/mL for LSD and iso-LSD and 10 pg/mL for nor-LSD and O-H-LSD. In urine, the LOD was 10 pg/mL for all analytes. Limits of quantitation (LOQ) in blood and urine were 20 pg/mL for LSD and iso-LSD and 50 pg/mL for nor-LSD and O-H-LSD. The method was linear, accurate, and precise from 10 to 2000 pg/mL in blood and 20 to 2000 pg/mL in urine for LSD and iso-LSD and from 20 to 2000 pg/mL in blood and 50 to 2000 pg/mL in urine for nor-LSD and O-H-LSD with a coefficient of determination (R(2)) > or = 0.99. The method was applied to blinded biological control samples and biological samples taken from a suspected LSD user. This is the first reported detection of O-H-LSD in blood from a suspected LSD user.

  4. Soft Decision Analyzer

    Science.gov (United States)

    Lansdowne, Chatwin; Steele, Glen; Zucha, Joan; Schlesinger, Adam

    2013-01-01

    We describe the benefit of using closed-loop measurements for a radio receiver paired with a counterpart transmitter. We show that real-time analysis of the soft decision output of a receiver can provide rich and relevant insight far beyond the traditional hard-decision bit error rate (BER) test statistic. We describe a Soft Decision Analyzer (SDA) implementation for closed-loop measurements on single- or dual- (orthogonal) channel serial data communication links. The analyzer has been used to identify, quantify, and prioritize contributors to implementation loss in live-time during the development of software defined radios. This test technique gains importance as modern receivers are providing soft decision symbol synchronization as radio links are challenged to push more data and more protocol overhead through noisier channels, and software-defined radios (SDRs) use error-correction codes that approach Shannon's theoretical limit of performance.

  5. KWU Nuclear Plant Analyzer

    International Nuclear Information System (INIS)

    Bennewitz, F.; Hummel, R.; Oelmann, K.

    1986-01-01

    The KWU Nuclear Plant Analyzer is a real time engineering simulator based on the KWU computer programs used in plant transient analysis and licensing. The primary goal is to promote the understanding of the technical and physical processes of a nuclear power plant at an on-site training facility. Thus the KWU Nuclear Plant Analyzer is available with comparable low costs right at the time when technical questions or training needs arise. This has been achieved by (1) application of the transient code NLOOP; (2) unrestricted operator interaction including all simulator functions; (3) using the mainframe computer Control Data Cyber 176 in the KWU computing center; (4) four color graphic displays controlled by a dedicated graphic computer, no control room equipment; and (5) coupling of computers by telecommunication via telephone

  6. Evaluation of containment hydrogen and oxygen analyzers

    International Nuclear Information System (INIS)

    Booth, H.R.; Stanley, L.

    1993-02-01

    This report contains information concerning operation and calibration of detectors utilized at US nuclear power plants for determining concentration of hydrogen and oxygen within the containment structure.A study was prompted by reports that several plants had experienced problems in operating, calibrating, and maintaining the detectors supplied by various vendors. A survey of all nuclear power plants was conducted to identify the specific problems. Discussions were held with key vendors concerning these problems. The major area of interest was centered around problems associated with calibration of the detectors. Many variations from plant-to-plant concerning calibration accuracies, calibration time periods, and frequencies were identified. Another area of prime consideration involved variations as to maintenance of the equipment. Some plants devoted considerable effort to in-house maintenance of equipment while others relied heavily on the vendor for such maintenance. A workshop was conducted with key utility and vendor personnel in attendance to discuss findings of the survey. It was resolved that a much improved coordinated effort between the vendors and utilities would be initiated as a means to resolve existing problems

  7. Emission spectrometric isotope analyzer

    International Nuclear Information System (INIS)

    Mauersberger, K.; Meier, G.; Nitschke, W.; Rose, W.; Schmidt, G.; Rahm, N.; Andrae, G.; Krieg, D.; Kuefner, W.; Tamme, G.; Wichlacz, D.

    1982-01-01

    An emission spectrometric isotope analyzer has been designed for determining relative abundances of stable isotopes in gaseous samples in discharge tubes, in liquid samples, and in flowing gaseous samples. It consists of a high-frequency generator, a device for defined positioning of discharge tubes, a grating monochromator with oscillating slit and signal converter, signal generator, window discriminator, AND connection, read-out display, oscillograph, gas dosing device and chemical conversion system with carrier gas source and vacuum pump

  8. TRIPLE PHASE SPIRAL C.T. IN THE EVALUATION OF HEPATIC MASSES

    Directory of Open Access Journals (Sweden)

    Prasad

    2015-10-01

    Full Text Available BACKGROUND AND OBJECTIVE : The goal of the study is to determine the value of various phases of Triple, Helical CT, Hepatic arterial Phase (HAP, Portal venous phase (PVP and Equilibrium Phase (EP, is the detection and characterization of Hepatic Lesions and to evaluate whether u nenhanced and hepatic arterial phases when used in conjunction with porto venous phase would lead to detection of greater number of lesions or better characterization of lesion. METHODOLOGY : The study population consists of 50 Patients aged between 30 Years and 80 Years were examined with multiphase (plain, hepatic arterial, portal venous and equilibrium phases. Spiral CT of liver. Patients were referred for CT scan when liver diseases were suspected clinically, if ultrasound and other previous investi gations revealed lesions which had to be further evaluated by spiral CT and to detect liver metastases in known cases of primary extra hepatic malignancy. CT TECHNIQUE: Helical scanning of liver with Toshiba astein s4, continuous spiral run and the images were reconstructed at 5mm intervals. Contrast material 100ml was injected through 18 or 20G catheter at the rate of 3ml per second using automatic medrad power injector. Non - ionic contrast [IOHEXOl – 300mg perml was used in all the patients]. After obtaine d unenhanced CT scan HAP scanning was initiated 25 seconds after initiation of contrast injection. Portal venous phase scanning was initiated 60 - 65 seconds after start of contrast injection. Equilibrium phase scanning was initiated after 180 seconds after the start of contrast injection. IMAGE EVALUATION: All the images of 4 phases were reviewed. First Step : The presence, appearance and enhancement of each Lesion were noted in all phases and lesion were described Isodense, Hypodense Hyperdense based on thei r attenuation relative to liver parenchyma during that phase of scanning. Based on enhancement pattern of the lesion during various phases they were

  9. Mass rearing and augmentative biological control evaluation of Rhynocoris fuscipes (Hemiptera: Reduviidae) against multiple pests of cotton.

    Science.gov (United States)

    Tomson, Majesh; Sahayaraj, Kitherian; Kumar, Vivek; Avery, Pasco B; McKenzie, Cindy L; Osborne, Lance S

    2017-08-01

    Rhynocoris fuscipes (Fab.) (Hemiptera: Reduviidae) is a generalist predator of cotton pests and is commonly found inhabiting cotton-growing regions in southern India. With the goal of integrating this predator in standard management practices used against cotton pests on a commercial scale, (1) we developed a protocol for adult group rearing of this predator inside micro-environmental cages (MECs), and (2) we evaluated the biocontrol potential of mass-produced predators against cotton pests under potted and field conditions. Higher fecundity and adult longevity of R. fuscipes was recorded in the MECs than under natural growing conditions. The reduviid predator preferred stones and fallen leaves as hiding places in the MECs. The predator showed a higher biocontrol potential during the night hours against two pests, Phenacoccus solenopsis Tinsley and Dysdercus cingulatus (Fab.), than during the day under potted conditions. Under field conditions, R. fuscipes significantly reduced the population of Aphis gossypii Glover, P. solenopsis, D. cingulatus and Helicoverpa armigera (Hübner) by 28, 70, 29 and 50%, respectively. No negative impact of R. fuscipes was reported on other natural enemies present in the cotton agroecosystem. Significantly higher crop yield and cost benefit ratio were observed in R. fuscipes-released plots than in the control plots. The results suggest that R. fuscipes can be mass produced efficiently under controlled conditions in MECs, and used in an integrated management program for multiple cotton pests. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  10. The impact of evaluating platelet transfusion need by platelet mass index on reducing the unnecessary transfusions in newborns.

    Science.gov (United States)

    Kahvecioglu, Dilek; Erdeve, Omer; Alan, Serdar; Cakir, Ufuk; Yildiz, Duran; Atasay, Begum; Arsan, Saadet

    2014-11-01

    Almost 95% of the platelet transfusions (PTs) conducted in the neonatal intensive care unit (NICU) are prophylactic transfusions. Guidelines for prophylactic PTs are based on platelet counts, but not on platelet functions. Nowadays, in order to reduce unnecessary transfusions, utilizing platelet mass index (PMI) was investigated. The aim of study is to find out whether PTs performed in our NICU during last 2 years were in accordance with the current guideline and to evaluate whether the frequency of PTs should be reduced if PMI was considered. Forty-three infants who received 96 prophylactic PTs were enrolled in the study. The guideline utilized in our NICU advocate keeping the platelet count: (a) >100 000 in pre/post-operative, (b) >50 000 in unstable and (c) >20 000 in stable patients. According to PMI criteria, PT should be performed if PMI: (a) platelet functions into account may yield lower transfusion rate, lower costs and better conservation of blood bank resources.

  11. Dose evaluation in function of the thyroid captivation percentage and mass in patients under radiotherapy for toxic goiter treatment

    International Nuclear Information System (INIS)

    Alves, Aline Nunes; Antonio Filho, Joao

    2009-01-01

    Rarely the patient's metabolism is pondered when the quantity of radioactive material administrated to the patient is calculated. Nowadays, realizing till 150 mCi/g activities treatments are not indicated to toxic goiter radiotherapy. This paper objectives to establish a group of 13I -treatment options optimization for owner toxic goiter patients to maximize benefits and minimize radiological detriments. Methodology consisted of effective and absorbed whole-body and the other organs doses evaluations. And to observe the relation between these values and the thyroid mass and captivation percentage. The results, in spite of characteristic variations of each patient, showed such a homogeneity. This phenomenon happens because of explicit dependency on the real activity administrated to the patient. Used protocols for the toxic goiter treatment optimization avoiding waste of radioisotopes. (author)

  12. The nitro-reduced metabolite of nimesulide: Crystal structure, spectroscopic characterization, ESI-QTOF mass spectrometric analysis and antibacterial evaluation

    Science.gov (United States)

    Nunes, Julia H. B.; Nakahata, Douglas H.; Lustri, Wilton R.; Corbi, Pedro P.; de Paiva, Raphael E. F.

    2018-04-01

    Here we present a synthetic procedure, spectroscopic characterization and single-crystal X-ray structure for the nitro-reduced metabolite of the anti-inflammatory drug nimesulide, hereby referred to as NMS-NH2. The nitro-reduced metabolite was synthesized using the Béchamp reduction (iron powder under acidic media), leading to the conversion of the nitrobenzene group of nimesulide to an aniline. Mass spectrometry, infrared and nuclear magnetic resonance spectroscopies data are also provided for NMS-NH2, and discussed in comparison to nimesulide. NMS-NH2 was also evaluated in terms of its antibacterial activities, considering that the free sbnd NH2 group could allow the compound to act as a dihydropteroate synthase inhibitor. NMS-NH2 had a modest antibacterial activity against P. aeruginosa (5.0 mg mL-1), which was not observed for NMS.

  13. To evaluate the effect of pre-pregnancy body mass index on maternal and perinatal outcomes among adolescent pregnant women.

    Science.gov (United States)

    Kansu-Celik, Hatice; Kisa Karakaya, Burcu; Guzel, Ali Irfan; Tasci, Yasemin; Erkaya, Salim

    2017-07-01

    To evaluate the effect of pre-pregnancy body mass index on maternal and perinatal outcomes among adolescent pregnant women. We conducted this prospective cross-sectional study on 365 singleton adolescent pregnancies (aged between 16 and 20 years) at a Maternity Hospital, between December 2014 and March 2015. We divided participants into two groups based on pre-pregnancy body mass index (BMI): overweight and obese adolescent (BMI at or above 25.0 kg/m) and normal weight (BMI between 18.5 and 24.99 kg/m) adolescent. We used multivariate analysis to evaluate the association of the risk of adverse pregnancy outcomes and pre-pregnancy BMI. The prevalence of maternal overweight/obesity and normal weight was 34.6% (n = 80) and 65.4% (n = 261) in the study population, respectively. Compared with normal-weight teens (n = 234), overweight/obese teens (n = 71) were at higher risk for cesarean delivery (odds ratio [OR] 0.7, 95% confidence interval [CI] 0.4-1.4), preeclampsia (adjusted odds ratio [OR] 0.1, 95% confidence interval [CI] 0.02-0.9) and small of gestational age (odds ratio [OR] 0.2, 95% confidence interval [CI] 0.1-0.9). BMI increased during pre-pregnancy could be an important preventable risk factor for poor obstetric complications in adolescent pregnancies, and for these patients prevention strategies (e.g., nutritional counseling, weight-loss, regular physical activity) for obesity are recommended before getting pregnant.

  14. Evaluation of matrix effect in isotope dilution mass spectrometry based on quantitative analysis of chloramphenicol residues in milk powder

    International Nuclear Information System (INIS)

    Li, Xiu Qin; Yang, Zong; Zhang, Qing He; Li, Hong Mei

    2014-01-01

    Graphical abstract: -- Highlights: •We develop a strategy to evaluate matrix effect and its impact on the IDMS results. •Matrix effect and IDMS correction factor from different conditions are evaluated. •Ion suppression effect is observed in LLE and HLB pre-treated sample solutions. •Ion enhancement effect is found in MCX pre-treated sample solution. •IDMS correction factor in HLB and MCX solutions in three instruments is close to 1 -- Abstract: In the present study, we developed a comprehensive strategy to evaluate matrix effect (ME) and its impact on the results of isotope dilution mass spectrometry (IDMS) in analysis of chloramphenicol (CAP) residues in milk powder. Stable isotope-labeled internal standards do not always compensate ME, which brings the variation of the ratio (the peak area of analyte/the peak area of isotope). In our investigation, impact factors of this variation were studied in the extraction solution of milk powder using three mass spectrometers coupled with different ion source designs, and deuterium-labeled chloramphenicol (D5-CAP) was used as the internal standard. ME from mobile phases, sample solvents, pre-treatment methods, sample origins and instruments was evaluated, and its impact on the results of IDMS was assessed using the IDMS correction factor (θ). Our data showed that the impact of ME of mobile phase on the correction factor was significantly greater than that of sample solvent. Significant ion suppression and enhancement effects were observed in different pre-treated sample solutions. The IDMS correction factor in liquid–liquid extraction (LLE) and molecular imprinted polymer (MIP) extract with different instruments was greater or less 1.0, and the IDMS correction factor in hydrophilic lipophilic balance (HLB) and mix-mode cation exchange (MCX) extract with different instruments was all close to 1.0. To the instrument coupled with different ion source design, the impact of ME on IDMS quantitative results was

  15. An evaluation of a mass media campaign to encourage parents of adolescents to talk to their children about sex.

    Science.gov (United States)

    DuRant, Robert H; Wolfson, Mark; LaFrance, Betty; Balkrishnan, Rajesh; Altman, David

    2006-03-01

    We evaluated a mass media campaign in North Carolina that used television (TV) public service announcements (PSAs), radio PSAs, and billboards to encourage parents of adolescents to talk to their children about sex. The primary message of the campaign was "Talk to your kids about sex. Everyone else is." Thirty-two of the 100 counties in North Carolina were chosen to evaluate the mass media campaign. Paid TV PSAs were aired in 22 of these counties, radio PSAs were aired in 21 counties, and billboards were displayed in 6 counties over a period of 9 months. The counties in our sample varied from no exposure to exposure to all 3 types of media. To assess the impact of the campaign, a sample of 1,132 parents of adolescents living in the 32 counties was administered a postexposure survey via a telephone interview. Questions about exposure to the media campaign were embedded among questions concerning media exposure to other health-related messages. The parent survey assessed the frequency the parents reported exposure to each type of media message, correct knowledge of the message, and multiple item scales that assessed how often they had talked to their child about various issues related to sex during the previous 6 months, intentions to talk to their child about these issues during the next month, and attitudes about discussing sexual issues with their child. In bivariate analyses the levels of parental exposure to the 3 types of media messages were associated with both having talked to their children and intentions to talk to their children about sex (p TV PSA about sex, and frequency of hearing a radio PSA about sex and teenage pregnancy accounted for 12.8% (p TV PSA about sex, and frequency of hearing radio PSAs about sex accounted for 12.3% of the variation in parental intentions to talk to their child about sex during the next month. Exposure to each component of this mass media campaign was associated with parents recently having talked to their adolescent

  16. Electrodynamic thermogravimetric analyzer

    International Nuclear Information System (INIS)

    Spjut, R.E.; Bar-Ziv, E.; Sarofim, A.F.; Longwell, J.P.

    1986-01-01

    The design and operation of a new device for studying single-aerosol-particle kinetics at elevated temperatures, the electrodynamic thermogravimetric analyzer (EDTGA), was examined theoretically and experimentally. The completed device consists of an electrodynamic balance modified to permit particle heating by a CO 2 laser, temperature measurement by a three-color infrared-pyrometry system, and continuous weighing by a position-control system. In this paper, the position-control, particle-weight-measurement, heating, and temperature-measurement systems are described and their limitations examined

  17. Analyzing Chinese Financial Reporting

    Institute of Scientific and Technical Information of China (English)

    SABRINA; ZHANG

    2008-01-01

    If the world’s capital markets could use a harmonized accounting framework it would not be necessary for a comparison between two or more sets of accounting standards. However,there is much to do before this becomes reality.This article aims to pres- ent a general overview of China’s General Accepted Accounting Principles(GAAP), U.S.General Accepted Accounting Principles and International Financial Reporting Standards(IFRS),and to analyze the differ- ences among IFRS,U.S.GAAP and China GAAP using fixed assets as an example.

  18. Inductive dielectric analyzer

    International Nuclear Information System (INIS)

    Agranovich, Daniel; Popov, Ivan; Ben Ishai, Paul; Feldman, Yuri; Polygalov, Eugene

    2017-01-01

    One of the approaches to bypass the problem of electrode polarization in dielectric measurements is the free electrode method. The advantage of this technique is that, the probing electric field in the material is not supplied by contact electrodes, but rather by electromagnetic induction. We have designed an inductive dielectric analyzer based on a sensor comprising two concentric toroidal coils. In this work, we present an analytic derivation of the relationship between the impedance measured by the sensor and the complex dielectric permittivity of the sample. The obtained relationship was successfully employed to measure the dielectric permittivity and conductivity of various alcohols and aqueous salt solutions. (paper)

  19. Using Ramped Pyrolysis - Gas Chromatography - Mass Spectrometry to Evaluate Petroleum Hydrocarbons Following the Deepwater Horizon Oil Spill

    Science.gov (United States)

    Evans, M.; Rosenheim, B. E.; Bacosa, H. P.; Liu, J.; Liu, Z.

    2016-02-01

    In summer of 2010, the Deepwater Horizon oil spill polluted hundreds of miles of coastline along the Gulf of Mexico. A combination of human-mediated and natural weathering processes then altered the chemical composition (i.e. toxicity) of this spilled crude oil over time and space. One of the most important, yet challenging, aspects of oil spill science is to quantify these chemical changes in natural environments. In this study, we develop ramped pyrolysis - gas chromatography - mass spectrometry (Py-GC-MS) to address this challenge. In this technique, 0.1mg of freeze-dried sample is pyrolyzed over a gradual temperature ramp (50-650°C). The eluded gas is cold-trapped over different thermal ranges (a.k.a. thermal slicing) and each range is individually analyzed via GC-MS, yielding quantifiable, compound-specific results. Py-GC-MS with thermal slicing has never been used for petroleum hydrocarbon analysis, but it has many advantages - it uses minimal sample, is time efficient and does not require sample preparation (minimizing compound loss and increasing the analytical window). During development of this method, we analyzed oiled sediments and tar collected on Grand Isle, Louisiana from 2010-2012. We quantified n-alkane (C10-C38), polycyclic aromatic hydrocarbon (PAH) and hopane content and confirmed these results with traditional solvent extraction, silica gel fractionation and mass spectrometry. Overall, we found rapid depletion of n-alkanes and PAHs (>90% depletion) in all samples within one year of Deepwater Horizon. After this, n-alkanes were almost 100% depleted by 2012, while PAH degradation continued to a maximum total degradation of 99% and 98% in sediment and tar, respectively. This not only describes the fate of petroleum compounds in salt marshes and beach deposits over time, but also complements previous radiocarbon studies of the same samples showing different rates of degradation in different micro-environments. In addition, the results presented

  20. School Readiness Factor Analyzed.

    Science.gov (United States)

    Brenner, Anton; Scott, Leland H.

    This paper is an empirical statistical analysis and interpretation of data relating to school readiness previously examined and reported on a theoretical basis. A total of 118 white, middle class children from six consecutive kindergarten groups in Dearborn, Michigan were tested with seven instruments, evaluated in terms of achievement, ability,…

  1. Plutonium solution analyzer

    International Nuclear Information System (INIS)

    Burns, D.A.

    1994-09-01

    A fully automated analyzer has been developed for plutonium solutions. It was assembled from several commercially available modules, is based upon segmented flow analysis, and exhibits precision about an order of magnitude better than commercial units (0.5%-O.05% RSD). The system was designed to accept unmeasured, untreated liquid samples in the concentration range 40-240 g/L and produce a report with sample identification, sample concentrations, and an abundance of statistics. Optional hydraulics can accommodate samples in the concentration range 0.4-4.0 g/L. Operating at a typical rate of 30 to 40 samples per hour, it consumes only 0.074 mL of each sample and standard, and generates waste at the rate of about 1.5 mL per minute. No radioactive material passes through its multichannel peristaltic pump (which remains outside the glovebox, uncontaminated) but rather is handled by a 6-port, 2-position chromatography-type loop valve. An accompanying computer is programmed in QuickBASIC 4.5 to provide both instrument control and data reduction. The program is truly user-friendly and communication between operator and instrument is via computer screen displays and keyboard. Two important issues which have been addressed are waste minimization and operator safety (the analyzer can run in the absence of an operator, once its autosampler has been loaded)

  2. Multiple capillary biochemical analyzer

    Science.gov (United States)

    Dovichi, N.J.; Zhang, J.Z.

    1995-08-08

    A multiple capillary analyzer allows detection of light from multiple capillaries with a reduced number of interfaces through which light must pass in detecting light emitted from a sample being analyzed, using a modified sheath flow cuvette. A linear or rectangular array of capillaries is introduced into a rectangular flow chamber. Sheath fluid draws individual sample streams through the cuvette. The capillaries are closely and evenly spaced and