WorldWideScience

Sample records for evaluate liquid cooling

  1. Toxicological evaluation of liquids proposed for use in direct contact liquid--liquid heat exchangers for solar heated and cooled buildings

    Energy Technology Data Exchange (ETDEWEB)

    Buchan, R.M.; Majestic, J.R.; Billau, R.

    1976-09-01

    This report contains the results of the toxicological evaluation part of the project entitled, ''Direct Contact Liquid-Liquid Heat Exchangers for Solar Heated and Cooled Buildings.'' Obviously any liquid otherwise suitable for use in such a device should be subjected to a toxicological evaluation. 34 liquids (24 denser than water, 10 less dense) have physical and chemical properties that would make them suitable for use in such a device. In addition to the complexity involved in selecting the most promising liquids from the standpoint of their chemical and physical properties is added the additional difficulty of also considering their toxicological properties. Some of the physical and chemical properties of these liquids are listed. The liquids are listed in alphabetical order within groups, the denser than water liquids are listed first followed by those liquids less dense than water.

  2. Characteristic evaluation of cooling technique using liquid nitrogen and metal porous media

    Energy Technology Data Exchange (ETDEWEB)

    Tanno, Yusuke; Ito, Satoshi; Hashizume, Hidetoshi [Department of Quantum Science and Energy Engineering, Graduate School of Engineering, Tohoku University, Sendai, Miyagi 980-8579 (Japan)

    2014-01-29

    A remountable high-temperature superconducting magnet, whose segments can be mounted and demounted repeatedly, has been proposed for construction and maintenance of superconducting magnet and inner reactor components of a fusion reactor. One of the issues in this design is that the performance of the magnet deteriorates by a local temperature rise due to Joule heating in jointing regions. In order to prevent local temperature rise, a cooling system using a cryogenic coolant and metal porous media was proposed and experimental studies have been carried out using liquid nitrogen. In this study, flow and heat transfer characteristics of cooling system using subcooled liquid nitrogen and bronze particle sintered porous media are evaluated through experiments in which the inlet degree of subcooling and flow rate of the liquid nitrogen. The flow characteristics without heat input were coincided with Ergun’s equation expressing single-phase flow in porous materials. The obtained boiling curve was categorized into three conditions; convection region, nucleate boiling region and mixed region with nucleate and film boiling. Wall superheat did not increase drastically with porous media after departure from nucleate boiling point, which is different from a situation of usual boiling curve in a smooth tube. The fact is important characteristic to cooling superconducting magnet to avoid its quench. Heat transfer coefficient with bronze particle sintered porous media was at least twice larger than that without the porous media. It was also indicated qualitatively that departure from nucleate boiling point and heat transfer coefficient depends on degree of subcooling and mass flow rate. The quantitative evaluation of them and further discussion for the cooling system will be performed as future tasks.

  3. Thermal Manikin Evaluation of Liquid Cooling Garments Intended for Use in Hazardous Waste Management

    Energy Technology Data Exchange (ETDEWEB)

    Dionne, J. P.; Semeniuk, K.; Makris, A.; Teal, W.; Laprise, B.

    2003-02-26

    Thermal manikins are valuable tools for quantitatively evaluating the performance of protective clothing ensembles and microclimate cooling systems. The goal of this investigation was to examine the performance of Coretech personal cooling systems, designed to reduce the effects of physiological and environmental heat stress, using a sweating thermal manikin. A sweating manikin takes into account the effective physiological evaporative heat transfer. Three tubesuits containing different densities of tubing were evaluated on the thermal manikin in conjunction with body armor and two Chemical-Biological suits (SPM and JSLIST). The experiments were carried out in an environmental chamber set at a temperature of 35 C with a relative humidity of 30%. For the tubesuits, two flow rates were tested and the heat removal rates were obtained by measuring the amount of power required to maintain the manikin's surface at a constant temperature of 35 C. The sweating rates were adjusted to maintain a fully wetted manikin surface at the above environmental conditions. For fluid flow rates ranging from approximately 250 to 750 ml/min, and inlet temperatures to the tubesuit ranging from 7 to 10 C, heat removal rates between 220 W to 284 W were measured, indicating the effectiveness of tubesuits at removing excessive body heat. This research was performed at the U.S. Army Soldier and Biological Chemical Command (SBCCOM) in Natick, Massachusetts.

  4. Innovation Incubator: LiquidCool Solutions Technical Evaluation. Laboratory Study and Demonstration Results of a Directed-Flow, Liquid Submerged Server for High-Efficiency Data Centers

    Energy Technology Data Exchange (ETDEWEB)

    Kozubal, Eric J [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2017-12-12

    LiquidCool Solutions (LCS) has developed liquid submerged server (LSS) technology that changes the way computer electronics are cooled. The technology provides an option to cool electronics by the direct contact flow of dielectric fluid (coolant) into a sealed enclosure housing all the electronics of a single server. The intimate dielectric fluid contact with electronics improves the effectiveness of heat removal from the electronics.

  5. FTU cooled liquid lithium upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Iafrati, M., E-mail: matteo.iafrati@enea.it [Associazione Euratom-ENEA sulla Fusione, C. R. Frascati, C. P. 65-00044 Frascati, Rome (Italy); Apicella, M.L.; Boncagni, L. [Associazione Euratom-ENEA sulla Fusione, C. R. Frascati, C. P. 65-00044 Frascati, Rome (Italy); Lyublinski, I. [JSC “RED STAR”, Moscow (Russian Federation); Mazzitelli, G. [Associazione Euratom-ENEA sulla Fusione, C. R. Frascati, C. P. 65-00044 Frascati, Rome (Italy); Vertkov, A. [JSC “RED STAR”, Moscow (Russian Federation)

    2017-04-15

    In the framework of the liquid lithium limiter experiment in Frascati a new auxiliary system was developed in order to provide a better control of the energy fluid vector. The cooled liquid lithium system (CLL) was installed for the first time at the end of 2013, it uses overheated water to heat the lithium and to extract, at the same time, the heat from the metal surface when it gets wet by the plasma. A first version of the system, developed and presented in previous papers, has been modified to optimize the heat flux measurement on the liquid lithium surface. The changes include a new power supply logic for the heating system, new sensors and new read-out electronics compatible with the implementation of a real time control system. The prototype was updated with the aim of achieving a low cost and versatile control system.

  6. Liquid metal cooled nuclear reactor plant system

    Science.gov (United States)

    Hunsbedt, Anstein; Boardman, Charles E.

    1993-01-01

    A liquid metal cooled nuclear reactor having a passive cooling system for removing residual heat resulting for fuel decay during reactor shutdown, or heat produced during a mishap. The reactor system is enhanced with sealing means for excluding external air from contact with the liquid metal coolant leaking from the reactor vessel during an accident. The invention also includes a silo structure which resists attack by leaking liquid metal coolant, and an added unique cooling means.

  7. Small Liquid Metal Cooled Reactor Safety Study

    Energy Technology Data Exchange (ETDEWEB)

    Minato, A; Ueda, N; Wade, D; Greenspan, E; Brown, N

    2005-11-02

    The Small Liquid Metal Cooled Reactor Safety Study documents results from activities conducted under Small Liquid Metal Fast Reactor Coordination Program (SLMFR-CP) Agreement, January 2004, between the Central Research Institute of the Electric Power Industry (CRIEPI) of Japan and the Lawrence Livermore National Laboratory (LLNL)[1]. Evaluations were completed on topics that are important to the safety of small sodium cooled and lead alloy cooled reactors. CRIEPI investigated approaches for evaluating postulated severe accidents using the CANIS computer code. The methods being developed are improvements on codes such as SAS 4A used in the US to analyze sodium cooled reactors and they depend on calibration using safety testing of metal fuel that has been completed in the TREAT facility. The 4S and the small lead cooled reactors in the US are being designed to preclude core disruption from all mechanistic scenarios, including selected unprotected transients. However, postulated core disruption is being evaluated to support the risk analysis. Argonne National Laboratory and the University of California Berkeley also supported LLNL with evaluation of cores with small positive void worth and core designs that would limit void worth. Assessments were also completed for lead cooled reactors in the following areas: (1) continuing operations with cladding failure, (2) large bubbles passing through the core and (3) recommendations concerning reflector control. The design approach used in the US emphasizes reducing the reactivity in the control mechanisms with core designs that have essentially no, or a very small, reactivity change over the core life. This leads to some positive void worth in the core that is not considered to be safety problem because of the inability to identify scenarios that would lead to voiding of lead. It is also believed that the void worth will not dominate the severe accident analysis. The approach used by 4S requires negative void worth throughout

  8. Liquid metal cooled reactors for space power applications

    Science.gov (United States)

    Bailey, S.; Vaidyanathan, S.; Van Hoomissen, J.

    1985-01-01

    The technology basis for evaluation of liquid metal cooled space reactors is summarized. Requirements for space nuclear power which are relevant to selection of the reactor subsystem are then reviewed. The attributes of liquid metal cooled reactors are considered in relation to these requirements in the areas of liquid metal properties, neutron spectrum characteristics, and fuel form. Key features of typical reactor designs are illustrated. It is concluded that liquid metal cooled fast spectrum reactors provide a high confidence, flexible option for meeting requirements for SP-100 and beyond.

  9. Liquid Cooling Technology Increases Exercise Efficiency

    Science.gov (United States)

    2015-01-01

    To keep astronauts' airtight spacesuits from becoming hot and humid, Ames Research Center developed liquid cooling garments that were integrated into each suit's long underwear. Vasper Systems, in San Jose, California, is using the technology in its liquid-cooled compression cuffs, which help people exercise more efficiently by concentrating lactic acid in their muscles.

  10. A Liquid Desiccant Enhanced Two Stage Evaporative Cooling System—Development and Performance Evaluation of a Test Rig

    Directory of Open Access Journals (Sweden)

    M. Mujahid Rafique

    2017-12-01

    Full Text Available Desiccant technology is found to be a good alternative to conventional cooling systems. It can provide better thermal comfort under hot and humid climatic conditions. The major component of a liquid desiccant cooling system is the desiccant dehumidifier which controls the latent cooling load. In this paper, a newly developed liquid desiccant enhanced evaporative cooling system has been tested experimentally. The effects of ambient conditions and other parameters on the performance of the system are investigated. The system performance curves which help to determine the air outlet conditions and coefficient of performance (COP of the system are drawn for a wide range of ambient air humidity ratios (0.010–0.026 kg/kg, ambient air temperature (25–40 °C, process air flow rate (1.5–8.0 kg/m2·s, regeneration air flow rate (1.5–4.5 kg/m2·s, and regeneration temperature (55–85 °C. The results showed that better supply air conditions are achieved for hot and humid climatic conditions with effectiveness of the system largely dependent on process and regeneration air flow rates, regeneration temperature, and humidity ratio of process air. The dehumidification performance is increased by 62% for a change of ambient air humidity ratio from 0.01 to 0.025 kg/kg. The thermal coefficient of performance improved by 50% for the above variation in humidity ratio. This shows that such thermally activated systems are feasible options for hot and humid climatic conditions as indicated by better performance under these conditions.

  11. Investigation of cooling and lubricating liquids

    OpenAIRE

    Heisel, Uwe; Lutz, Marcel

    1993-01-01

    Considering increasing waste disposal problems in the area of cooling and lubricating liquids as well as their potential of health hazard and environmental endangering the question is to ask to what extend the customary way of cooling and lubrication in metalworking is still in keeping with the times. Several approaches to solve this problem seem to be suitable to guarantee a better human and environmental agreeableness as well as a smaller consumption. To make a reliable statement about the ...

  12. Regenerative cooling for liquid rocket engines

    Science.gov (United States)

    Qi, Feng

    1995-01-01

    Heat transfer in the thrust chamber is of great importance in the design of liquid propellant rocket engines. Regenerative cooling is an advanced method which can ensure not only the proper running but also higher performance of a rocket engine. The theoretical model is complicated, it relates to fluid dynamics, heat transfer, combustion, etc... In this paper, a regenerative cooling model is presented. Effects such as radiation, heat transfer to environment, variable thermal properties and coking are included in the model. This model can be applied to all kinds of liquid propellant rocket engines as well as similar constructions. The modularized computer code is completed in the work.

  13. Direct Liquid Cooling for Electronic Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Coles, Henry; Greenberg, Steve

    2014-03-01

    This report documents a demonstration of an electronic--equipment cooling system in the engineering prototype development stage that can be applied in data centers. The technology provides cooling by bringing a water--based cooling fluid into direct contact with high--heat--generating electronic components. This direct cooling system improves overall data center energy efficiency in three ways: High--heat--generating electronic components are more efficiently cooled directly using water, capturing a large portion of the total electronic equipment heat generated. This captured heat reduces the load on the less--efficient air--based data center room cooling systems. The combination contributes to the overall savings. The power consumption of the electronic equipment internal fans is significantly reduced when equipped with this cooling system. The temperature of the cooling water supplied to the direct cooling system can be much higher than that commonly provided by facility chilled water loops, and therefore can be produced with lower cooling infrastructure energy consumption and possibly compressor-free cooling. Providing opportunities for heat reuse is an additional benefit of this technology. The cooling system can be controlled to produce high return water temperatures while providing adequate component cooling. The demonstration was conducted in a data center located at Lawrence Berkeley National Laboratory in Berkeley, California. Thirty--eight servers equipped with the liquid cooling system and instrumented for energy measurements were placed in a single rack. Two unmodified servers of the same configuration, located in an adjacent rack, were used to provide a baseline. The demonstration characterized the fraction of heat removed by the direct cooling technology, quantified the energy savings for a number of cooling infrastructure scenarios, and provided information that could be used to investigate heat reuse opportunities. Thermal measurement data were used

  14. Liquid Acquisition Device Testing with Sub-Cooled Liquid Oxygen

    Science.gov (United States)

    Jurns, John M.; McQuillen, John B.

    2008-01-01

    When transferring propellant in space, it is most efficient to transfer single phase liquid from a propellant tank to an engine. In earth s gravity field or under acceleration, propellant transfer is fairly simple. However, in low gravity, withdrawing single-phase fluid becomes a challenge. A variety of propellant management devices (PMD) are used to ensure single-phase flow. One type of PMD, a liquid acquisition device (LAD) takes advantage of capillary flow and surface tension to acquire liquid. Previous experimental test programs conducted at NASA have collected LAD data for a number of cryogenic fluids, including: liquid nitrogen (LN2), liquid oxygen (LOX), liquid hydrogen (LH2), and liquid methane (LCH4). The present work reports on additional testing with sub-cooled LOX as part of NASA s continuing cryogenic LAD development program. Test results extend the range of LOX fluid conditions examined, and provide insight into factors affecting predicting LAD bubble point pressures.

  15. Liquid-cooled nuclear reactor. [Patent:; PWR

    Energy Technology Data Exchange (ETDEWEB)

    Deinlein, H.; Kummer, G.

    1980-04-24

    H/sub 2/ is directly added to the coolant circuit. This requires a pipe bypassing the volume expansion tank and being connected with the suction side of the high pressure pump. The supply of H/sub 2/ is realized via ceramic filter catridges in a liquid cooled part of the pipe at the suction side of the high pressure pump. Thus, the danger of oxyhydrogen explosions is avoided.

  16. Cooling by immersion in liquid nitrogen

    Science.gov (United States)

    Listerman, Thomas W.; Boshinski, Thomas A.; Knese, Lynn F.

    1986-06-01

    When an object is cooled by immersion in a liquid, there is an unexpected increase in the violence of boiling just before the boiling stops. Most people seem fascinated by this phenomenon yet few are acquainted with its explanation in terms of a change in the heat-transfer mechanism from film boiling to nucleate boiling. We have developed two variations of an intermediate level undergraduate laboratory experiment to measure the heat-transfer rate after a sample is immersed in liquid nitrogen. The temperature of the sample, as measured by a thermocouple, is recorded as a function of time using either a potentiometer strip-chart recorder or a digital voltmeter-microcomputer combination. The heat-transfer rate as a function of sample temperature is computed from these results, and the reason for the effect is clearly seen.

  17. Espresso coffee foam delays cooling of the liquid phase.

    Science.gov (United States)

    Arii, Yasuhiro; Nishizawa, Kaho

    2017-04-01

    Espresso coffee foam, called crema, is known to be a marker of the quality of espresso coffee extraction. However, the role of foam in coffee temperature has not been quantitatively clarified. In this study, we used an automatic machine for espresso coffee extraction. We evaluated whether the foam prepared using the machine was suitable for foam analysis. After extraction, the percentage and consistency of the foam were measured using various techniques, and changes in the foam volume were tracked over time. Our extraction method, therefore, allowed consistent preparation of high-quality foam. We also quantitatively determined that the foam phase slowed cooling of the liquid phase after extraction. High-quality foam plays an important role in delaying the cooling of espresso coffee.

  18. RF cavity using liquid dielectric for tuning and cooling

    Science.gov (United States)

    Popovic, Milorad [Warrenville, IL; Johnson, Rolland P [Newport News, VA

    2012-04-17

    A system for accelerating particles includes an RF cavity that contains a ferrite core and a liquid dielectric. Characteristics of the ferrite core and the liquid dielectric, among other factors, determine the resonant frequency of the RF cavity. The liquid dielectric is circulated to cool the ferrite core during the operation of the system.

  19. Investigation of the cooling film distribution in liquid rocket engine

    Directory of Open Access Journals (Sweden)

    Luís Antonio Silva

    2011-05-01

    Full Text Available This study presents the results of the investigation of a cooling method widely used in the combustion chambers, which is called cooling film, and it is applied to a liquid rocket engine that uses as propellants liquid oxygen and kerosene. Starting from an engine cooling, whose film is formed through the fuel spray guns positioned on the periphery of the injection system, the film was experimentally examined, it is formed by liquid that seeped through the inner wall of the combustion chamber. The parameter used for validation and refinement of the theoretical penetration of the film was cooling, as this parameter is of paramount importance to obtain an efficient thermal protection inside the combustion chamber. Cold tests confirmed a penetrating cold enough cooling of the film for the length of the combustion chamber of the studied engine.

  20. Efficient energy storage in liquid desiccant cooling systems

    Energy Technology Data Exchange (ETDEWEB)

    Hublitz, Astrid

    2008-07-18

    Liquid Desiccant Cooling Systems (LDCS) are open loop sorption systems for air conditioning that use a liquid desiccant such as a concentrated salt solution to dehumidify the outside air and cool it by evaporative cooling. Thermochemical energy storage in the concentrated liquid desiccant can bridge power mismatches between demand and supply. Low-flow LDCS provide high energy storage capacities but are not a state-of-the-art technology yet. The key challenge remains the uniform distribution of the liquid desiccant on the heat and mass transfer surfaces. The present research analyzes the factors of influence on the energy storage capacity by simulation of the heat and mass transfer processes and specifies performance goals for the distribution of the process media. Consequently, a distribution device for the liquid desiccant is developed that reliably meets the performance goals. (orig.)

  1. Thermohydraulic safety issues for liquid metal cooled systems

    Energy Technology Data Exchange (ETDEWEB)

    Gerbeth, Gunter; Stefani, Frank [Helmholtz-Zentrum Dresden-Rossendorf (HZDR) e.V., Dresden (Germany). Inst. of Fluid Dynamics; Eckert, Sven

    2016-05-15

    In this paper recent developments of various techniques for single-phase and two-phase flow measurements with relevance to liquid metal cooled systems will be presented. Further, the status of the DRESDYN platform for large-scale experiments with liquid sodium is sketched.

  2. Demonstration of liquid crystal for barocaloric cooling application

    OpenAIRE

    Xie, Zhongjian; Zhu, Yao

    2016-01-01

    Current vapor-compression technology is based on the gas-liquid transition of hazardous gas. The alternative cooling technology focuses on the solid caloric material. A new liquid barocaloric material, i.e. the liquid crystal, is proved to be potential for cooling application primarily (based on other literatures). Its phase transition needs a small stress (tens of MPa) and can be operated near room temperature. It has a large entropy change of ~200 J.K-1.kg-1 (0.2 J.K-1.cm-1). There is no br...

  3. Liquid metal reactor air cooling baffle

    Science.gov (United States)

    Hunsbedt, A.

    1994-08-16

    A baffle is provided between a relatively hot containment vessel and a relatively cold silo for enhancing air cooling performance. The baffle includes a perforate inner wall positionable outside the containment vessel to define an inner flow riser therebetween, and an imperforate outer wall positionable outside the inner wall to define an outer flow riser therebetween. Apertures in the inner wall allow thermal radiation to pass laterally therethrough to the outer wall, with cooling air flowing upwardly through the inner and outer risers for removing heat. 3 figs.

  4. Development of a Very Dense Liquid Cooled Compute Platform

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, Phillip N.; Lipp, Robert J.

    2013-12-10

    The objective of this project was to design and develop a prototype very energy efficient high density compute platform with 100% pumped refrigerant liquid cooling using commodity components and high volume manufacturing techniques. Testing at SLAC has indicated that we achieved a DCIE of 0.93 against our original goal of 0.85. This number includes both cooling and power supply and was achieved employing some of the highest wattage processors available.

  5. Economizer Based Data Center Liquid Cooling with Advanced Metal Interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Timothy Chainer

    2012-11-30

    A new chiller-less data center liquid cooling system utilizing the outside air environment has been shown to achieve up to 90% reduction in cooling energy compared to traditional chiller based data center cooling systems. The system removes heat from Volume servers inside a Sealed Rack and transports the heat using a liquid loop to an Outdoor Heat Exchanger which rejects the heat to the outdoor ambient environment. The servers in the rack are cooled using a hybrid cooling system by removing the majority of the heat generated by the processors and memory by direct thermal conduction using coldplates and the heat generated by the remaining components using forced air convection to an air- to- liquid heat exchanger inside the Sealed Rack. The anticipated benefits of such energy-centric configurations are significant energy savings at the data center level. When compared to a traditional 10 MW data center, which typically uses 25% of its total data center energy consumption for cooling this technology could potentially enable a cost savings of up to $800,000-$2,200,000/year (assuming electricity costs of 4 to 11 cents per kilowatt-hour) through the reduction in electrical energy usage.

  6. Critical Current Test of Liquid Hydrogen Cooled HTC Superconductors under External Magnetic Field

    Science.gov (United States)

    Shirai, Yasuyuki; Shiotsu, Masahiro; Tatsumoto, Hideki; Kobayashi, Hiroaki; Naruo, Yoshihiro; Nonaka, Satoshi; Inatani, Yoshifumi

    High-Tc (HTC) superconductors including MgB2 will show excellent properties under temperature of Liquid Hydrogen (LH2:20K), which has large latent heat and low viscosity coefficient. In order to design and fabricate the LH2 cooled superconducting energy devices, we must clear the cooling property of LH2 for superconductors, the cooling system and safety design of LH2 cooled superconducting devices and electro-magnetic property evaluation of superconductors (BSCCO, REBCO and MgB2) and their magnets cooled by LH2. As the first step of the study, an experimental setup which can be used for investigating heat transfer characteristics of LH2 in a pool and also in forced flow (circulation loop with a pump), and also for evaluation of electro-magnetic properties of LH2 cooled superconductors under external magnetic field (up to 7 T). In this paper, we will show a short sketch of the experimental set-up, practical experiences in safety operation of liquid hydrogen cooling system and example test results of critical current evaluation of HTC superconductors cooled by LH2.

  7. Correlation of liquid-film cooling mass transfer data.

    Science.gov (United States)

    Gater, R. A.; L'Ecuyer, M. R.

    1972-01-01

    An empirical correlation proposed by Gater and Ecuyer (1970) for liquid-film cooling mass transfer, accounting for film roughness and entrainment effects, is extended to include liquid films of arbitrary length. A favorable comparison between the predicted results and the experimental data of Kinney et al. (1952) and Emmons and Warner (1964) shows the utility of the mass transfer correlation for predictions over a wide range of experimental parameters.

  8. Regeneratively Cooled Liquid Oxygen/Methane Technology Development

    Science.gov (United States)

    Robinson, Joel W.; Greene, Christopher B.; Stout, Jeffrey

    2012-01-01

    The National Aeronautics & Space Administration (NASA) has identified Liquid Oxygen (LOX)/Liquid Methane (LCH4) as a potential propellant combination for future space vehicles based upon exploration studies. The technology is estimated to have higher performance and lower overall systems mass compared to existing hypergolic propulsion systems. NASA-Marshall Space Flight Center (MSFC) in concert with industry partner Pratt & Whitney Rocketdyne (PWR) utilized a Space Act Agreement to test an oxygen/methane engine system in the Summer of 2010. PWR provided a 5,500 lbf (24,465 N) LOX/LCH4 regenerative cycle engine to demonstrate advanced thrust chamber assembly hardware and to evaluate the performance characteristics of the system. The chamber designs offered alternatives to traditional regenerative engine designs with improvements in cost and/or performance. MSFC provided the test stand, consumables and test personnel. The hot fire testing explored the effective cooling of one of the thrust chamber designs along with determining the combustion efficiency with variations of pressure and mixture ratio. The paper will summarize the status of these efforts.

  9. Computer Simulation of the Cool Down of the ATLAS Liquid Argon Barrel Calorimeter

    CERN Document Server

    Korperud, N; Fabre, C; Owren, G; Passardi, Giorgio

    2002-01-01

    The ATLAS electromagnetic barrel calorimeter consists of a liquid argon detector with a total mass of 120 tonnes. This highly complicated structure, fabricated from copper, lead, stainless steel and glass-fiber reinforced epoxy will be placed in an aluminum cryostat. The cool down process of the detector will be limited by the maximum temperature differences accepted by the composite structure so as to avoid critical mechanical stresses. A computer program simulating the cool down of the detector by calculating the local heat transfer throughout a simplified model has been developed. The program evaluates the cool down time as a function of different contact gasses filling the spaces within the detector.

  10. Liquid Cooling System for CPU by Electroconjugate Fluid

    Directory of Open Access Journals (Sweden)

    Yasuo Sakurai

    2014-06-01

    Full Text Available The dissipated power of CPU for personal computer has been increased because the performance of personal computer becomes higher. Therefore, a liquid cooling system has been employed in some personal computers in order to improve their cooling performance. Electroconjugate fluid (ECF is one of the functional fluids. ECF has a remarkable property that a strong jet flow is generated between electrodes when a high voltage is applied to ECF through the electrodes. By using this strong jet flow, an ECF-pump with simple structure, no sliding portion, no noise, and no vibration seems to be able to be developed. And then, by the use of the ECF-pump, a new liquid cooling system by ECF seems to be realized. In this study, to realize this system, an ECF-pump is proposed and fabricated to investigate the basic characteristics of the ECF-pump experimentally. Next, by utilizing the ECF-pump, a model of a liquid cooling system by ECF is manufactured and some experiments are carried out to investigate the performance of this system. As a result, by using this system, the temperature of heat source of 50 W is kept at 60°C or less. In general, CPU is usually used at this temperature or less.

  11. Numerical study of wave disturbance in liquid cooling film

    Directory of Open Access Journals (Sweden)

    S.R. Shine

    2013-06-01

    Full Text Available Transient numerical simulations are carried out to investigate the liquid-gas interface characteristics associated with liquid film cooling flows. A two-dimensional axisymmetric multi-phase numerical model using finite volume formulation is developed. The model has been validated against available experimental data for liquid-film cooling flows inside tubes. The model has been used to predict the interface characteristics for a variety of imposed parameters and momentum flux ratios under cold flow conditions wherein both the coolant and mainstream are maintained at the same temperature. Disturbance waves are observed at the liquid-gas interface for coolant flows above a critical value and after a finite distance from the inlet. The distance toward the wave inception point increased with the increase of momentum flux ratio. However, at higher momentum flux ratios, the properties of the disturbance waves did not vary significantly. The parameters related to the liquid-gas interface waves, namely, wave velocity, frequency, amplitude and wave length have been analyzed in detail. Analysis indicates that the liquid entrainment is due to the shearing of the disturbance wave crest.

  12. Thermally safe operation of a cooled semi-batch reactor: slow liquid-liquid reactions

    NARCIS (Netherlands)

    Steensma, M.; Westerterp, K.R.

    1988-01-01

    Thermally safe operation of a semi-batch reactor (SBR) implies that conditions leading to strong accumulation of unreacted reactants must be avoided. All thermal responses of a SBR, in which a slow liquid-liquid reaction takes place, can be represented in a diagram with the kinetics, cooling

  13. New Mexico cloud super cooled liquid water survey final report 2009.

    Energy Technology Data Exchange (ETDEWEB)

    Beavis, Nick; Roskovensky, John K.; Ivey, Mark D.

    2010-02-01

    Los Alamos and Sandia National Laboratories are partners in an effort to survey the super-cooled liquid water in clouds over the state of New Mexico in a project sponsored by the New Mexico Small Business Assistance Program. This report summarizes the scientific work performed at Sandia National Laboratories during the 2009. In this second year of the project a practical methodology for estimating cloud super-cooled liquid water was created. This was accomplished through the analysis of certain MODIS sensor satellite derived cloud products and vetted parameterizations techniques. A software code was developed to analyze multiple cases automatically. The eighty-one storm events identified in the previous year effort from 2006-2007 were again the focus. Six derived MODIS products were obtained first through careful MODIS image evaluation. Both cloud and clear-sky properties from this dataset were determined over New Mexico. Sensitivity studies were performed that identified the parameters which most influenced the estimation of cloud super-cooled liquid water. Limited validation was undertaken to ensure the soundness of the cloud super-cooled estimates. Finally, a path forward was formulized to insure the successful completion of the initial scientific goals which include analyzing different of annual datasets, validation of the developed algorithm, and the creation of a user-friendly and interactive tool for estimating cloud super-cooled liquid water.

  14. Liquid nitrogen cooling in IR thermography applied to steel specimen

    Science.gov (United States)

    Lei, L.; Ferrarini, G.; Bortolin, A.; Cadelano, G.; Bison, P.; Maldague, X.

    2017-05-01

    Pulsed Thermography (PT) is one of the most common methods in Active Thermography procedures of the Thermography for NDT & E (Nondestructive Testing & Evaluation), due to the rapidity and convenience of this inspection technique. Flashes or lamps are often used to heat the samples in the traditional PT. This paper mainly explores exactly the opposite external stimulation in IR Thermography: cooling instead of heating. A steel sample with flat-bottom holes of different depths and sizes has been tested. Liquid nitrogen (LN2) is sprinkled on the surface of the specimen and the whole process is captured by a thermal camera. To obtain a good comparison, two other classic NDT techniques, Pulsed Thermography and Lock-In Thermography, are also employed. In particular, the Lock-in method is implemented with three different frequencies. In the image processing procedure, the Principal Component Thermography (PCT) method has been performed on all thermal images. For Lock-In results, both Phase and Amplitude images are generated by Fast Fourier Transform (FFT). Results show that all techniques presented part of the defects while the LN2 technique displays the flaws only at the beginning of the test. Moreover, a binary threshold post-processing is applied to the thermal images, and by comparing these images to a binary map of the location of the defects, the corresponding Receiver Operating Characteristic (ROC) curves are established and discussed. A comparison of the results indicates that the better ROC curve is obtained using the Flash technique with PCT processing method.

  15. Liquid-cooled nuclear reactor. Kernreaktor mit einem fluessigen Kuehlmittel

    Energy Technology Data Exchange (ETDEWEB)

    Deinlein, H.; Kummer, G.

    1984-07-26

    H/sub 2/ is directly added to the coolant circuit. This requires a pipe bypassing the volume expansion tank and being connected with the suction side of the high pressure pump. The supply of H/sub 2/ is realized via ceramic filter catridges in a liquid cooled part of the pipe at the suction side of the high pressure pump. Thus, the danger of oxyhydrogen explosions is avoided.

  16. MHD considerations for a self-cooled liquid lithium blanket

    Energy Technology Data Exchange (ETDEWEB)

    Sze, D.K.; Mattas, R.F.; Hull, A.B.; Picologlou, B.F.; Smith, D.L.

    1992-03-01

    The magnetohydrodynamic (MHD) effects can present a feasibility issue for a self-cooled liquid metal blanket of magnetically confined fusion reactors, especially inboard regime of a tokamak. This pressure drop can be significantly reduced by using insulated wall structure. A self-healing insulating coating has been identified, which will reduce the pressure drop by more than a factor of 10. The future research direction to further quantify the performance of this coating is also outlined.

  17. High Performance Mars Liquid Cooling and Ventilation Garment Project

    Science.gov (United States)

    Terrier, Douglas; Clayton, Ronald; Whitlock, David; Conger, Bruce

    2015-01-01

    EVA space suit mobility in micro-gravity is enough of a challenge and in the gravity of Mars, improvements in mobility will enable the suited crew member to efficiently complete EVA objectives. The idea proposed is to improve thermal efficiencies of the liquid cooling and ventilation garment (LCVG) in the torso area in order to free up the arms and legs by removing the liquid tubes currently used in the ISS EVA suit in the limbs. By using shaped water tubes that greatly increase the contact area with the skin in the torso region of the body, the heat transfer efficiency can be increased to provide the entire liquid cooling requirement and increase mobility by freeing up the arms and legs. Additional potential benefits of this approach include reduced LCVG mass, enhanced evaporation cooling, increased comfort during Mars EVA tasks, and easing of the overly dry condition in the helmet associated with the Advanced Extravehicular Mobility Unit (EMU) ventilation loop currently under development.

  18. Simplified thermochemistry of oxygen in lithium and sodium for liquid metal cooling systems

    Science.gov (United States)

    Tower, L. K.

    1972-01-01

    Plots of oxygen chemical potential against composition of lithium-oxygen solutions and sodium-oxygen solutions for a range of temperature were constructed. For each liquid metal two such plots were prepared. For one plot ideal solution behavior was assumed. For the other plot, existing solubility limit data for oxygen in the liquid metal were used to determine a first-order term for departure from ideality. The use of the plots in evaluating the oxygen gettering capability of refractory metals in liquid metal cooling systems is illustrated by a simple example involving lithium, oxygen, and hafnium.

  19. Liquid desiccant dehumidification and regeneration process to meet cooling and freshwater needs of desert greenhouses

    KAUST Repository

    Lefers, Ryan

    2016-04-19

    Agriculture accounts for ~70% of freshwater usage worldwide. Seawater desalination alone cannot meet the growing needs for irrigation and food production, particularly in hot, desert environments. Greenhouse cultivation of high-value crops uses just a fraction of freshwater per unit of food produced when compared with open field cultivation. However, desert greenhouse producers face three main challenges: freshwater supply, plant nutrient supply, and cooling of the greenhouse. The common practice of evaporative cooling for greenhouses consumes large amounts of fresh water. In Saudi Arabia, the most common greenhouse cooling schemes are fresh water-based evaporative cooling, often using fossil groundwater or energy-intensive desalinated water, and traditional refrigeration-based direct expansion cooling, largely powered by the burning of fossil fuels. The coastal deserts have ambient conditions that are seasonally too humid to support adequate evaporative cooling, necessitating additional energy consumption in the dehumidification process of refrigeration-based cooling. This project evaluates the use of a combined-system liquid desiccant dehumidifier and membrane distillation unit that can meet the dual needs of cooling and freshwater supply for a greenhouse in a hot and humid environment. © 2016 Balaban Desalination Publications. All rights reserved.

  20. Comparison of immersed liquid and air cooling of NASA's Airborne Information Management System

    Science.gov (United States)

    Hoadley, A. W.; Porter, A. J.

    1992-01-01

    The Airborne Information Management System (AIMS) is currently under development at NASA Dryden Flight Research Facility. The AIMS is designed as a modular system utilizing surface mounted integrated circuits in a high-density configuration. To maintain the temperature of the integrated circuits within manufacturer's specifications, the modules are to be filled with Fluorinert FC-72. Unlike ground based liquid cooled computers, the extreme range of the ambient pressures experienced by the AIMS requires the FC-72 be contained in a closed system. This forces the latent heat absorbed during the boiling to be released during the condensation that must take within the closed module system. Natural convection and/or pumping carries the heat to the outer surface of the AIMS module where the heat transfers to the ambient air. This paper will present an evaluation of the relative effectiveness of immersed liquid cooling and air cooling of the Airborne Information Management System.

  1. Solar assisted liquid desiccant cooling using clay based membranes

    Directory of Open Access Journals (Sweden)

    Priya S. Shanmuga

    2018-01-01

    Full Text Available The environmental concerns have led to the urge of the usage of non-conventional energy resources like solar, wind, thermal, geothermal etc. which provide enormous source of energy without causing any further diminution of the environment. Instead of the conventional HVAC systems that cause colossal environmental perils, usage of liquid desiccants in coming in vogue whereby reducing ecological threats. Moreover, solar assisted systems provide further impulse to such systems. This paper discusses about the various comparisons between liquid desiccants: Lithium chloride, Potassium formate and Calcium chloride and concludes that potassium formate is the best desiccant to be used among the three. Potassium formate (HCOOK is used which is cheaper and less corrosive as compared to the other aqueous salts, and has a negative crystallization temperature. Potassium formate is a new liquid desiccant and thus, not much research is available currently. The weather conditions of Manipal provide an appropriate condition for the experimentations of solar aided liquid desiccant evaporative cooling systems due to its humid climate and intense solar radiation obtained. The small scale experimentation also encounters the problem of liquid desiccant carryover by the air flow, with the help of clay based membranes which are again cheap, environmentally benign and obtained in a facile way. The projected system takes complete advantage of pure solar energy aimed at the regeneration of liquid desiccant.

  2. Time-resolved crystallization of deeply cooled liquid hydrogen isotopes

    Energy Technology Data Exchange (ETDEWEB)

    Kuehnel, Matthias

    2014-02-15

    This thesis serves two main purposes: 1. The introduction of a novel experimental method to investigate phase change dynamics of supercooled liquids 2. First-time measurements for the crystallization behaviour for hydrogen isotopes under various conditions (1) The new method is established by the synergy of a liquid microjet of ∼ 5 μm diameter and a scattering technique with high spatial resolution, here linear Raman spectroscopy. Due to the high directional stability and the known velocity of the liquid filament, its traveling axis corresponds to a time axis static in space. Utilizing evaporative cooling in a vacuum environment, the propagating liquid cools down rapidly and eventually experiences a phase transition to the crystalline state. This temporal evolution is probed along the filament axis, ultimately resulting in a time resolution of 10 ns. The feasibility of this approach is proven successfully within the following experiments. (2) A main object of study are para-hydrogen liquid filaments. Raman spectra reveal a temperature gradient of the liquid across the filament. This behaviour can quantitatively be reconstructed by numerical simulations using a layered model and is rooted in the effectiveness of evaporative cooling on the surface and a finite thermal conductivity. The deepest supercoolings achieved are ∼ 30% below the melting point, at which the filament starts to solidify from the surface towards the core. With a crystal growth velocity extracted from the data the appropriate growth mechanism is identified. The crystal structure that initially forms is metastable and probably the result of Ostwald's rule of stages. Indications for a transition within the solid towards the stable equilibrium phase support this interpretation. The analog isotope ortho-deuterium is evidenced to behave qualitatively similar with quantitative differences being mass related. In further measurements, isotopic mixtures of para-hydrogen and ortho-deuterium are

  3. Development and fabrication of an advanced liquid cooling garment

    Science.gov (United States)

    Leith, J. R.; Hixon, C. W.

    1976-01-01

    The elastomeric film fin/tube concept which was developed is a composite of polyurethane film, fine expanded silver mesh, a serpentine pattern polyurethane transport tubing and an integral comfort liner, all bonded via adhesive application and vacuum-bagged for final cure. As demonstrated by thermal analysis, the composite garment material is capable of removing a 293 watt (1000 BTU/hr) metabolic load through a head and torso cooling area of .46 sq m (5 sq ft) with tube spacing of slightly under one inch. A total of 60 test elements, each .15m x .15m (6 in. x 6 in.) were fabricated in support of the liquid cooling garment concept development. In parallel with the fabrication of these elements a continuing series of laboratory tests to support the fabrication techniques was carried out. The elements and supporting tests are described.

  4. Permeability evolution model and numerical analysis of coupled coal deformation, failure and liquid nitrogen cooling

    Directory of Open Access Journals (Sweden)

    Chunhui ZHANG

    Full Text Available How to quantitatively evaluate the permeability change of coalbed subjected to liquid nitrogen cooling is a key issue of enhanced-permeability technology of coalbed. To analyze the evolution process of permeability of coupled coal deformation, failure and liquid introgen cooling, the coal is supposed as elastic, brittle and plastic material. Its deformation process includes elastic deformation stage, brittle strength degradation stage and residual plastic flow stage. Combined with strength degradation index, dilatancy index of the element and Mohr-Column strength criterion, the element scale constitutive model with the effects of confining pressure on peak-post mechanical behaviors is built. Based on the deformation process of coal rock, there exist two stages of permeability evolution of the element including decrease of permeability due to elastic contraction and increase due to coal rock element's failure. The relationships between the permeability and elastic deformation, shear failure and tension failure for coal are studied. The permeability will be influenced by the change of pore space due to elastic contraction or tension of element. Conjugate shear zones appear during the shear failure of the element, in which the flow follows so-called cubic law between smooth parallel plates. The calculation formulas of the permeability and the aperture of the fractures are given out based on the volumetric strain. When tension failure criterion is satisfied with the rock element fails and two orthogonal fractures appear. The calculation formulas of the permeability and the width of the fractures are given out based on the volumetric strain. Further, combined with the thermal conduction theory the permeability evolution model of coupled coal deformation, failure and liquid nitrogen cooling is presented. Then Fish function method in FLAC is employed to perform the model. The permeability's evolution process for coal bed cryogenically stimulated

  5. Experimental evaluation of cooling efficiency of the high performance cooling device

    Energy Technology Data Exchange (ETDEWEB)

    Nemec, Patrik, E-mail: patrik.nemec@fstroj.uniza.sk; Malcho, Milan, E-mail: milan.malcho@fstroj.uniza.sk [University of Žilina, Faculty of Mechanical Engineering, Department of Power Engineering, Univerzitna 1, 010 26 Žilina (Slovakia)

    2016-06-30

    This work deal with experimental evaluation of cooling efficiency of cooling device capable transfer high heat fluxes from electric elements to the surrounding. The work contain description of cooling device, working principle of cooling device, construction of cooling device. Experimental part describe the measuring method of device cooling efficiency evaluation. The work results are presented in graphic visualization of temperature dependence of the contact area surface between cooling device evaporator and electronic components on the loaded heat of electronic components in range from 250 to 740 W and temperature dependence of the loop thermosiphon condenser surface on the loaded heat of electronic components in range from 250 to 740 W.

  6. Experimental Evidence for a Liquid-Liquid Crossover in Deeply Cooled Confined Water

    Science.gov (United States)

    Cupane, Antonio; Fomina, Margarita; Piazza, Irina; Peters, Judith; Schirò, Giorgio

    2014-11-01

    In this work we investigate, by means of elastic neutron scattering, the pressure dependence of mean square displacements (MSD) of hydrogen atoms of deeply cooled water confined in the pores of a three-dimensional disordered SiO2 xerogel; experiments have been performed at 250 and 210 K from atmospheric pressure to 1200 bar. The "pressure anomaly" of supercooled water (i.e., a mean square displacement increase with increasing pressure) is observed in our sample at both temperatures; however, contrary to previous simulation results and to the experimental trend observed in bulk water, the pressure effect is smaller at lower (210 K) than at higher (250 K) temperature. Elastic neutron scattering results are complemented by differential scanning calorimetry data that put in evidence, besides the glass transition at about 170 K, a first-order-like endothermic transition occurring at about 230 K that, in view of the neutron scattering results, can be attributed to a liquid-liquid crossover. Our results give experimental evidence for the presence, in deeply cooled confined water, of a crossover occurring at about 230 K (at ambient pressure) from a liquid phase predominant at 210 K to another liquid phase predominant at 250 K; therefore, they are fully consistent with the liquid-liquid transition hypothesis.

  7. Monitoring system for a liquid-cooled nuclear fission reactor

    Science.gov (United States)

    DeVolpi, Alexander

    1987-01-01

    A monitoring system for detecting changes in the liquid levels in various regions of a water-cooled nuclear power reactor, viz., in the downcomer, in the core, in the inlet and outlet plenums, at the head, and elsewhere; and also for detecting changes in the density of the liquid in these regions. A plurality of gamma radiation detectors are used, arranged vertically along the outside of the reactor vessel, and collimator means for each detector limits the gamma-radiation it receives as emitting from only isolated regions of the vessel. Excess neutrons produced by the fission reaction will be captured by the water coolant, by the steel reactor walls, or by the fuel or control structures in the vessel. Neutron capture by steel generates gamma radiation having an energy level of the order of 5-12 MeV, whereas neutron capture by water provides an energy level of approximately 2.2 MeV, and neutron capture by the fission fuel or its cladding provides an energy level of 1 MeV or less. The intensity of neutron capture thus changes significantly at any water-metal interface. Comparative analysis of adjacent gamma detectors senses changes from the normal condition with liquid coolant present to advise of changes in the presence and/or density of the coolant at these specific regions. The gamma detectors can also sense fission-product gas accumulation at the reactor head to advise of a failure of fuel-pin cladding.

  8. Use of volatile organic solvents in headspace liquid-phase microextraction by direct cooling of the organic drop using a simple cooling capsule.

    Science.gov (United States)

    Ghiasvand, Ali Reza; Yazdankhah, Fatemeh; Hajipour, Somayeh

    2016-08-01

    A low-cost and simple cooling-assisted headspace liquid-phase microextraction device for the extraction and determination of 2,6,6-trimethyl-1,3 cyclohexadiene-1-carboxaldehyde (safranal) in Saffron samples, using volatile organic solvents, was fabricated and evaluated. The main part of the cooling-assisted headspace liquid-phase microextraction system was a cooling capsule, with a Teflon microcup to hold the extracting organic solvent, which is able to directly cool down the extraction phase while the sample matrix is simultaneously heated. Different experimental factors such as type of organic extraction solvent, sample temperature, extraction solvent temperature, and extraction time were optimized. The optimal conditions were obtained as: extraction solvent, methanol (10 μL); extraction temperature, 60°C; extraction solvent temperature, 0°C; and extraction time, 20 min. Good linearity of the calibration curve (R(2) = 0.995) was obtained in the concentration range of 0.01-50.0 μg/mL. The limit of detection was 0.001 μg/mL. The relative standard deviation for 1.0 μg/mL of safranal was 10.7% (n = 6). The proposed cooling-assisted headspace liquid-phase microextraction device was coupled (off-line) to high-performance liquid chromatography and used for the determination of safranal in Saffron samples. Reasonable agreement was observed between the results of the cooling-assisted headspace liquid-phase microextraction high-performance liquid chromatography method and those obtained by a validated ultrasound-assisted solvent extraction procedure. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Evaluation of cooling tower environmental effects

    Energy Technology Data Exchange (ETDEWEB)

    Nicholas, G.W.; Sopocy, D.M.

    1974-11-01

    Cooling towers interact with the environment through the discharge of blowdown to a lake or stream and through the emission of moisture and warmed air to the atmosphere. The environmental effects of these interactions can be evaluated by measuring various physical and chemical properties of the cooling system and of the ambient meteorology and hydrology. Blowdown parameters used in this evaluation are temperature, pH, flow rate, total dissolved solids, biocide, and inhibitor concentrations. In addition to meteorological parameters, the atmospheric parameters which require evaluation include fogging, drift, salt deposition, and moist plume characteristics. The instrumentation needs for monitoring these parameters are discussed with respect to current status. Concepts and instrumentation requiring additional development are also cited. Instrumentation required for the measurement of meteorology, humidity, wind speed and direction, atmospheric temperature and stability, height of the mixed layer, fogging, visibility, and drift are included. Fog dispersal techniques are mentioned. (Air Pollut. Abstr.)

  10. Development of self-cooled liquid metal breeder blankets

    Energy Technology Data Exchange (ETDEWEB)

    Malang, S.; Tillack, M.S. [comps.; Barleon, L.; Baumgaertner, S.; Borgstedt, H.U.; Buehler, L.; Buerkle, G.; Dammel, F.; Feuerstein, H.; Fischer, U.; Gabel, K.; Gerhardt, H.; Glasbrenner, H.; Heider, T.; Jordan, T.; Kleefeldt, K.; Kleykamp, H.; Lindau, R.; Moeslang, A.; Norajitra, F.; Reimann, G.; Reimann, J.; Riesch-Oppermann, H.; Ritzhaupt-Kleissl, H.J.; Schleisiek, K.; Schmitz, G.; Schnauder, H.; Stieglitz, R.; Tellini, B.; Tsige-Tamirat, H.

    1995-11-01

    The development of liquid metal breeder blankets for fusion reactors has been performed in the Forschungszentrum Karlsruhe as a part of the European fusion blanket development program with the aim to select the two most promising concepts in 1995 for further development. In this report are described the designs of self-cooled blankets together with the results of the accompanying R and D program of the years 1992-1995. The program includes design studies as well as theoretical and experimental work in the fields of neutronics, magneto-hydrodynamics, thermohydraulics, mechanical stresses, compatibility and purification of lead-lithium, tritium extraction and control, safety, reliability, electrical insulating coatings, and fabrication technologies for blanket segments. (orig.) 250 refs.

  11. Reliability and Maintainability Data for Liquid Metal Cooling Systems

    Energy Technology Data Exchange (ETDEWEB)

    Cadwallader, Lee Charles [Idaho National Laboratory

    2015-05-01

    One of the coolants of interest for future fusion breeding blankets is lead-lithium. As a liquid metal it offers the advantages of high temperature operation for good station efficiency, low pressure, and moderate flow rate. This coolant is also under examination for use in test blanket modules to be used in the ITER international project. To perform reliability, availability, maintainability and inspectability (RAMI) assessment as well as probabilistic safety assessment (PSA) of lead-lithium cooling systems, component failure rate data are needed to quantify the system models. RAMI assessment also requires repair time data and inspection time data. This paper presents a new survey of the data sets that are available at present to support RAMI and PSA quantification. Recommendations are given for the best data values to use when quantifying system models.

  12. Liquid cooled plate heat exchanger for battery cooling of an electric vehicle (EV)

    Science.gov (United States)

    Rahman, M. M.; Rahman, H. Y.; Mahlia, T. M. I.; Sheng, J. L. Y.

    2016-03-01

    A liquid cooled plate heat exchanger was designed to improve the battery life of an electric vehicle which suffers from premature aging or degradation due to the heat generation during discharging and charging period. Computational fluid dynamics (CFD) was used as a tool to analyse the temperature distribution when a constant surface heat flux was set at the bottom surface of the battery. Several initial and boundary conditions were set based on the past studies on the plate heat exchanger in the simulation software. The design of the plate heat exchanger was based on the Nissan Leaf battery pack to analyse the temperature patterns. Water at different mass flow rates was used as heat transfer fluid. The analysis revealed the designed plate heat exchanger could maintain the surface temperature within the range of 20 to 40°C which is within the safe operating temperature of the battery.

  13. Evaluation of helium cooling for fusion divertors

    Energy Technology Data Exchange (ETDEWEB)

    Baxi, C.B.

    1993-09-01

    The divertors of future fusion reactors will have a power throughput of several hundred MW. The peak heat flux on the diverter surface is estimated to be 5 to 15 MW/m{sup 2} at an average heat flux of 2 MW/m{sup 2}. The divertors have a requirement of both minimum temperature (100{degrees}C) and maximum temperature. The minimum temperature is dictated by the requirement to reduce the absorption of plasma, and the maximum temperature is determined by the thermo-mechanical properties of the plasma facing materials. Coolants that have been considered for fusion reactors are water, liquid metals and helium. Helium cooling has been shown to be very attractive from safety and other considerations. Helium is chemically and neutronically inert and is suitable for power conversion. The challenges associated with helium cooling are: (1) Manifold sizes; (2) Pumping power; and (3) Leak prevention. In this paper the first two of the above design issues are addressed. A variety of heat transfer enhancement techniques are considered to demonstrate that the manifold sizes and the pumping power can be reduced to acceptable levels. A helium-cooled diverter module was designed and fabricated by GA for steady-state heat flux of 10 MW/m{sup 2}. This module was recently tested at Sandia National Laboratories. At an inlet pressure of 4 MPa, the module was tested at a steady-state heat flux of 10 MW/m{sup 2}. The pumping power required was less than 1% of the power removed. These results verified the design prediction.

  14. Design and Comparative Analysis of a Retrofitted Liquid Cooling System for High-Power Actuators

    Directory of Open Access Journals (Sweden)

    Nicholas Paine

    2015-08-01

    Full Text Available This paper presents an in-depth system-level experimental analysis comparing air-cooled and liquid-cooled commercial off-the-shelf (COTS electric motors. Typically, liquid-cooled electric motors are reserved for large, expensive, high-end applications where the design of the motor’s electromagnetic components are closely coupled to its cooling system. By applying liquid cooling to a pre-existing motor design, this work helps bring the performance advantages of liquid cooling to smaller scale and lower cost applications. Prior work in this area gives little insight to designers of such systems. Conversely, this work aims to improve the understanding of liquid-cooled COTS motors by reporting empirically-observed factors of improvement for motor current, torque, output power and system efficiency. These measurements are obtained using a new liquid-cooled motor housing design that improves the ease of maintenance and component reuse compared to existing work. It is confirmed that datasheet motor thermal properties may serve as a reasonable guide for anticipating continuous torque performance, but may over-specify continuous power output. For the motor used in this test, continuous torque output is increased by a factor of 2.58, matching to within 9% of expected datasheet values. Continuous power output is increased by a factor of two with only 2.2% reduced efficiency compared to air-cooling.

  15. Delamination of graphite oxide in a liquid upon cooling.

    Science.gov (United States)

    Talyzin, Alexandr V; Klechikov, Alexey; Korobov, Mikhail; Rebrikova, Anastasiya T; Avramenko, Nataliya V; Gholami, M Fardin; Severin, Nikolai; Rabe, Jürgen P

    2015-08-07

    Graphite oxide (GO) in liquid acetonitrile undergoes a transition from an ordered phase around ambient temperature to a gel-like disordered phase at temperatures below 260 K, as demonstrated by in situ X-ray diffraction. The stacking order of GO layers is restored below the freezing point of acetonitrile (199 K). The reversible swelling transition between a stacked crystalline phase and an amorphous delaminated state observed upon cooling provides an unusual example of increased structural disorder at lower temperatures. The formation of the gel-like phase is attributed to the thermo-responsive conformational change of individual GO flakes induced by stronger solvation. Scanning force microscopy demonstrates that GO flakes deposited onto a solid substrate from acetonitrile dispersions at a temperature below 260 K exhibit corrugations and wrinkling which are not observed for the flakes deposited at ambient temperature. The thermo-responsive transition between the delaminated and stacked phases reported here can be used for sonication-free dispersion of graphene oxide, micro-container applications, or the preparation of new composite materials.

  16. Experimentally Determined Heat Transfer Coefficients for Spacesuit Liquid Cooled Garments

    Science.gov (United States)

    Bue, Grant; Watts, Carly; Rhodes, Richard; Anchondo, Ian; Westheimer, David; Campbell, Colin; Vonau, Walt; Vogel, Matt; Conger, Bruce

    2015-01-01

    A Human-In-The-Loop (HITL) Portable Life Support System 2.0 (PLSS 2.0) test has been conducted at NASA Johnson Space Center in the PLSS Development Laboratory from October 27, 2014 to December 19, 2014. These closed-loop tests of the PLSS 2.0 system integrated with human subjects in the Mark III Suit at 3.7 psi to 4.3 psi above ambient pressure performing treadmill exercise at various metabolic rates from standing rest to 3000 BTU/hr (880 W). The bulk of the PLSS 2.0 was at ambient pressure but effluent water vapor from the Spacesuit Water Membrane Evaporator (SWME) and the Auxiliary Membrane Evaporator (Mini-ME), and effluent carbon dioxide from the Rapid Cycle Amine (RCA) were ported to vacuum to test performance of these components in flight-like conditions. One of the objectives of this test was to determine the heat transfer coefficient (UA) of the Liquid Cooling Garment (LCG). The UA, an important factor for modeling the heat rejection of an LCG, was determined in a variety of conditions by varying inlet water temperature, flowrate, and metabolic rate. Three LCG configurations were tested: the Extravehicular Mobility Unit (EMU) LCG, the Oceaneering Space Systems (OSS) LCG, and the OSS auxiliary LCG. Other factors influencing accurate UA determination, such as overall heat balance, LCG fit, and the skin temperature measurement, will also be discussed.

  17. Design analyses of self-cooled liquid metal blankets

    Energy Technology Data Exchange (ETDEWEB)

    Gohar, Y.

    1986-12-01

    A trade-off study of liquid metal self-cooled blankets was carried out to define the performance of these blankets and to determine the potential to operate at the maximum possible values of the performance parameters. The main parameters considered during the course of the study were the tritium breeding ratio (TBR), the blanket energy multiplication factor, the energy fraction lost to the shield, the lithium-6 enrichment in the breeder material, the total blanket thickness, the reflector material selection, and the compositions of the different blanket zones. Also, a study was carried out to assess the impact of different reactor design choices on the reactor performance parameters. The design choices include the impurity control system (limiter or divertor), the material choice for the limiter, the elimination of tritium breeding from the inboard section of tokamak reactors, and the coolant choice for the nonbreeding inboard blanket. In addition, tritium breeding benchmark calculations were performed using different transport codes and nuclear data libraries. The importance of the TBR in the blanket design motivated the benchmark calculations.

  18. Solutions for Liquid Nitrogen Pre-Cooling in Helium Refrigeration Cycles

    CERN Document Server

    Wagner, U

    2000-01-01

    Pre-cooling of helium by means of liquid nitrogen is the oldest and one of the most common process features used in helium liquefiers and refrigerators. Its two principle tasks are to allow or increase the rate of pure liquefaction, and to permit the initial cool-down of large masses to about 80 K. Several arrangements for the pre-cooling process are possible depending on the desired application. Each arrangement has its proper advantages and drawbacks. The aim of this paper is to review the possible process solutions for liquid nitrogen pre-cooling and their particularities.

  19. Liquid Cooling of Tractive Lithium Ion Batteries Pack with Nanofluids Coolant.

    Science.gov (United States)

    Li, Yang; Xie, Huaqing; Yu, Wei; Li, Jing

    2015-04-01

    The heat generated from tractive lithium ion batteries during discharge-charge process has great impacts on the performances of tractive lithium ion batteries pack. How to solve the thermal abuse in tractive lithium ion batteries pack becomes more and more urgent and important for future development of electrical vehicles. In this work, TiO2, ZnO and diamond nanofluids are prepared and utilized as coolants in indirect liquid cooling of tractive lithium ion batteries pack. The results show that nanofluids present superior cooling performance to that of pure fluids and the diamond nanofluid presents relatively excellent cooling abilities than that of TiO2 and ZnO nanofluids. During discharge process, the temperature distribution of batteries in batteries pack is uniform and stable, due to steady heat dissipation by indirect liquid cooling. It is expected that nanofluids could be considered as a potential alternative for indirect liquid cooling in electrical vehicles.

  20. MEMS based pumped liquid cooling systems for micro/nano spacecraft thermal control

    Science.gov (United States)

    Birur, G. C.; Shakkottai, P.; Sur, T. W

    2001-01-01

    The objective is to develop MEMS based pumped liquid cooling system for removing over 20 W/cm squared from high power density microelectronics and science payloads considered for future micro/nano sciencecraft.

  1. CTE-Matched, Liquid-Cooled, High Thermal Conductivity Heat Sink Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose the development of a CTE-matched, liquid-cooled, high thermal conductivity heat sink for use in spacecraft thermal management applications. The material...

  2. A Liquid Hydrogen Cooler with a Cooling Capacity of 20 Watts Project

    Data.gov (United States)

    National Aeronautics and Space Administration — For the future spaceport and long-term storage of liquid hydrogen NASA requires cryocoolers that can provide cooling power in the range of 20 watts at 20 K. The...

  3. Light-Weight, Low-Cost, Single-Phase, Liquid-Cooled Cold Plate (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Narumanchi, S.

    2013-07-01

    This presentation, 'Light-Weight, Low-Cost, Single-Phase Liquid-Cooled Cold Plate,' directly addresses program goals of increased power density, specific power, and lower cost of power electronics components through improved thermal management.

  4. Light-Weight, Single-Phase, Liquid-Cooled Cold Plate (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Narumanchi, S.

    2013-07-01

    This presentation, 'Light-Weight, Low-Cost, Single-Phase Liquid-Cooled Cold Plate,' directly addresses program goals of increased power density, specific power, and lower cost of power electronics components through improved thermal management.

  5. Direct-to-chip liquid cooling for reducing power consumption in a subarctic supercomputer centre

    OpenAIRE

    Ovaska, Seppo J.; Dragseth, Roy Einar; Hanssen, Svenn Agnar

    2016-01-01

    Publisher's pdf. Source at http://doi.org/10.1504/IJHPCN.2016.076269 Reduction of data centre power consumption is a timely challenge. Waste heat reuse is another focus area when developing energy efficient and sustainable data centres. And these two issues are interconnected through liquid cooling of server racks and/or direct-to-chip liquid cooling. Both of these solutions make it possible to transfer a significant proportion of the waste heat energy back to profitable use. Nevertheless,...

  6. Energy efficient data center liquid cooling with geothermal enhancement

    Energy Technology Data Exchange (ETDEWEB)

    Chainer, Timothy J.; Parida, Pritish R.

    2017-11-07

    A data center cooling system is operated in a first mode, and has an indoor portion wherein heat is absorbed from components in the data center by a heat transfer fluid, and an outdoor heat exchanger portion and a geothermal heat exchanger portion. The first mode includes ambient air cooling of the heat transfer fluid in the outdoor heat exchanger portion and/or geothermal cooling of the heat transfer fluid in the geothermal heat exchanger portion. Based on an appropriate metric, a determination is made that a switch should be made from the first mode to a second mode; and, in response, the data center cooling system is switched to the second mode. The second mode is different than the first mode.

  7. Development of a technique to evaluate the performance of cooling headers and its applications in POSCO plate mills

    Directory of Open Access Journals (Sweden)

    Kang Jong-Hoon

    2016-01-01

    Full Text Available Hundreds of thousands of liquid jet nozzles are widely used in controling cooling equipment to accelerate the cooling of hot plates. The holes of these nozzles become clogged or the hole size becomes smaller as foreign substances like grease, scrap, and mud containing cooling water are flushed through. In this case, cooling water sprays abnormally through the partially clogged or restricted nozzle. This causes inhomogeneous cooling of hot plates. The objective of this study is to develop an evaluation system of cooling headers including nozzles. This paper presents the method to evaluate the conditions of spraying nozzles. The sensor developed in this research measures the liquid column of spraying nozzles using differential pressure between the inside sensor block and ambient air. In addition, the results of a field test in a real, large factory are introduced in this paper.

  8. Numerical study of liquid film cooling in a rocket combustion chamber

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, H.W.; Tao, W.Q.; He, Y.L.; Zhang, W. [State Key Laboratory of Multiphase Flow in Power Engineering, Xi' an Jiaotong University, Xi' an (China)

    2006-01-15

    A numerical study is reported to investigate the liquid film cooling in a rocket combustion chamber. Mass, momentum and heat transfer characteristics through the interface are considered in detail. A marching procedure is employed for solution of the respective governing equations for the liquid film and gas stream together. The standard turbulence k-{epsilon} model is used to simulate the turbulence gas flow and a modified van Driest model is adopted to simulate the turbulent liquid film flow. Radiation of gas stream is also considered and simulated with the flux model. Downstream of the liquid film the gaseous film cooling is numerically studied simultaneously. Results are presented for a mixed gases-water system under different condition. Various effects on the liquid film length are examined in detail. There is a good agreement between the numerical prediction and experimental result on the liquid film length. (author)

  9. Analysis of a liquid metal cooled blanket transient using ATHENA

    Energy Technology Data Exchange (ETDEWEB)

    Roth, P.A.; Chow, H.

    1985-01-01

    A comprehensive safety analysis code called ATHENA, Advanced Thermal Hydraulic Energy Network Analyzer, is being developed by EG and G Idaho as part of the Fusion Safety Program. This code can be used to analyze transients and system interactions in fusion reactors with a wide variety of coolant, breeder, structural, and magnet materials. In the past, the code has been used to analyze a helium cooled blanket module and a water cooled blanket concept. As new concepts in fusion reactor designs evolve, the ATHENA code developers will add the necessary capabilities to model those concepts.

  10. The development of evaporative liquid film model for analysis of passive containment cooling system

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hong June; Hwang, Young Dong; Kim, Hee Cheol; Kim, Young In; Chang, Moon Hee

    2000-07-01

    An analytical model was developed to simulate behavior of the liquid film formed on the outside surface of the steel containment vessel of PCCS including the ellipsoidal dome and the vertical wall. The model was coupled with CFX code using the user subroutines provided by the code, and a series of numerical calculations were performed to evaluate the evaporative heat transfer coefficient at the interface. Numerical results for Sherwood number and evaporative heat transfer coefficient were compared with the experimental data. The results were in good agreement with the experimental data. The calculated liquid film thickness showed good agreement with that of Sun except an upper portion of the channel. The model was applied to the full scale of PCCS to investigate the effects of dome and chimney on the evaporation rate. The results showed that the heat transfer coefficient in the dome region, where the flow cross-sectional area decreases and the swirling occurs, was lower than that of the vertical annulus region. The calculated evaporative heat transfer coefficient was about 20 times larger than that of the dry cooling. Sensitivity studies on the gap size and the wall temperature were also performed to figure out their effects on the heat transfer coefficient and inlet air average velocity. Through the analysis of the dryout point, the minimum liquid film flow rate to cover the entire surface of the vessel was estimated.

  11. Liquid metal corrosion/erosion investigations of structure materials in lead cooled systems: Part 1

    Science.gov (United States)

    Kieser, M.; Muscher, H.; Weisenburger, A.; Heinzel, A.; Müller, G.

    2009-08-01

    In future lead cooled nuclear power systems the heavy liquid-metal pump will be placed in the hot temperature region of the reactor. This combines corrosion problematic at elevated temperatures with erosion at the impeller of the pump. Several steels designed for conventional mechanical high loaded pumps and the SiSiC have been tested in oxygen containing stagnant lead (10 -6 and 10 -8 wt%) at 550 and 600 °C for 2000 and 4000 h in the COSTA-facilities. Only SiSiC shows no influence by the liquid metal. No dissolution attack occurs at cast iron steels but inner oxidation takes place. NORILOY shows no dissolution attack. All other steels are attacked by liquid lead at one of the conditions. To evaluate the erosion-corrosion attack a new test facility allowing velocities of the lead of up to 20 m/s was designed and constructed. With a CFD-code the behaviour and flow velocity of the lead are simulated.

  12. The Small Modular Liquid Metal Cooled Reactor: A New Approach to Proliferation Risk Management

    Energy Technology Data Exchange (ETDEWEB)

    Smith, C F; Crawford, D; Cappiello, M; Minato, A; Herczeg, J W

    2003-11-12

    There is an ongoing need to supply energy to small markets and remote locations with limited fossil fuel infrastructures. The Small, Modular, Liquid-Metal-Cooled Reactor, also referred to as SSTAR (Small, Secure, Transportable, Autonomous Reactor), can provide reliable and cost-effective electricity, heat, fresh water, and potentially hydrogen transportation fuels for these markets. An evaluation of a variety of reactor designs indicates that SSTAR, with its secure, long-life core, has many advantages for deployment into a variety of national and international markets. In this paper, we describe the SSTAR concept and its approach to safety, security, environmental and non-proliferation. The system would be design-certified using a new license-by-test approach, and demonstrated for commercial deployment anywhere in the world. The project addresses a technology development need (i.e., a small secure modular system for remote sites) that is not otherwise addressed in other currently planned research programs.

  13. Assessment of an active liquid cooling garment intended for use in a hot environment.

    Science.gov (United States)

    Bartkowiak, Grazyna; Dabrowska, Anna; Marszalek, Anna

    2017-01-01

    This paper discusses the construction of a designed active liquid cooling garment (LCG) that has been developed in order to reduce thermal discomfort of persons working in hot environments. It consists of clothing with a tube system distributing a cooling liquid, a sensor measuring the microclimate under the clothing, and a portable cooling unit with a module controlling the temperature of the cooling liquid depending on the microclimate temperature under the clothing. The LCG was validated through tests on volunteers in a climatic chamber at 30 °C, a relative humidity of 40%, and an air movement rate of 0.4 m/s. The obtained test results confirmed the beneficial effects of the cooling system used on mean weighted skin temperature, the physical parameters of the microclimate under the clothing, and the participants' subjective assessments, as well as confirmed that the functioning of the control system regulating liquid temperature in the LCG was correct. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Updated reference design of a liquid metal cooled tandem mirror fusion breeder

    Energy Technology Data Exchange (ETDEWEB)

    Berwald, D.H.; Whitley, R.H.; Garner, J.K.; Gromada, R.J.; McCarville, T.J.; Moir, R.W.; Lee, J.D.; Bandini, B.R.; Fulton, F.J.; Wong, C.P.C.; Maya, I.; Hoot, C.G.; Schultz, K.R.; Miller, L.G.; Beeston, J.M.; Harris, B.L.; Westman, R.A.; Ghoniem, N.M.; Orient, G.; Wolfer, M.; DeVan, J.H.; Torterelli, P.

    1985-09-01

    Detailed studies of key techinical issues for liquid metal cooled fusion breeder (fusion-fission hybrid blankets) have been performed during the period 1983-4. Based upon the results of these studies, the 1982 reference liquid metal cooled tandem mirror fusion breeder blanket design was updated and is described. The updated reference blankets provides increased breeding and lower technological risk in comparison with the original reference blanket. In addition to the blanket design revisions, a plant concept, cost, and fuel cycle economics assessment is provided. The fusion breeder continues to promise an economical source of fissile fuel for the indefinite future.

  15. Analysis of a liquid metal cooled blanket transient using ATHENA

    Energy Technology Data Exchange (ETDEWEB)

    Roth, P.A.; Chow, H.

    1985-07-01

    The ATHENA code is being developed by EG and G Idaho as a general purpose thermal hydraulics code for safety transient analysis in fusion reactors. This report documents the use of ATHENA to model a lithium-lead cooled fusion reactor design. The code models the MHD effects resulting from the flow of a conducting fluid through a strong steady magnetic field. The code performed well within the range of available lithium-lead properties. The results from calculations of several operational transients and a loss of pumping power are reported.

  16. Evaluation of thermal-storage concepts for solar cooling applications

    Science.gov (United States)

    Hughes, P. J.; Morehouse, J. H.; Choi, M. K.; White, N. M.; Scholten, W. B.

    1981-10-01

    Various configuration concepts for utilizing thermal energy storage to improve the thermal and economic performance of solar cooling systems for buildings were analyzed. The storge concepts evaluated provide short-term thermal storge via the bulk containment of water or salt hydrates. The evaluations were made for both residential-size cooling systems (3-ton) and small commercial-size cooling systems (25-ton). The residential analysis considers energy requirements for space heating, space cooling and water heating, while the commercial building analysis is based only on energy requirements for space cooling. The commercial building analysis considered a total of 10 different thermal storage/solar systems, 5 each for absorption and Rankine chiller concepts. The residential analysis considered 4 thermal storage/solar systems, all utilizing an absorption chiller. The trade-offs considered include: cold-side versus hot-side storage, single vs multiple stage storage, and phase-change vs sensible heat storage.

  17. Estimation of turbulent mixing model for the application to liquid metal-cooled reactors

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, H. Y.; Ha, K. S.; Chang, W. P.; Lee, Y. B.; Heo, S

    2003-12-01

    It is required to model accurately the inter-subchannel mixing phenomenon for the improved prediction in the subchannel analysis and the flow blockage analysis of a Liquid Metal-cooled Reactor (LMR). When there exists a single-phase flow in the subchannels, the mixing of mass, energy and momentum between the subchannels can be divided into two parts, the diversion flow due to the pressure gradient and the cross flow mainly due to the turbulent mixing. To enlarge the understanding on turbulent mixing, the general turbulent models of zero-equation model, one-equation model and two-equation model are briefly introduced. Further, the turbulent mixing models, which are used in the subchannel codes such as MATRA-LMR, COBRA-IV, SABRE and ASFRE-III, are summarized. The bases of the turbulent mixing models in most subchannel codes are the mixing-length theory and the research results obtained before 1980's. The SABRE code includes the forms of one-equation model and two-equation model, but some experimental constants are essential to use those models. The recent experimental and analytical studies on turbulent mixing are surveyed and the important results are summarized. Some state-of-the-art turbulent mixing models are implemented in MATRA-LMR code and the effect of the models was evaluated for ORNL 19-pin data. The results imply the correlation by Rehme is the most suitable as a turbulent model for liquid metal-cooled reactors for wide range of fluidic conditions. To get more accurate distributions of flow and temperature for low flow conditions, it is recommended to have more accurate thermal conduction correction factor.

  18. Regeneratively Cooled Liquid Oxygen/Methane Technology Development Between NASA MSFC and PWR

    Science.gov (United States)

    Robinson, Joel W.; Greene, Christopher B.; Stout, Jeffrey B.

    2012-01-01

    The National Aeronautics & Space Administration (NASA) has identified Liquid Oxygen (LOX)/Liquid Methane (LCH4) as a potential propellant combination for future space vehicles based upon exploration studies. The technology is estimated to have higher performance and lower overall systems mass compared to existing hypergolic propulsion systems. NASA-Marshall Space Flight Center (MSFC) in concert with industry partner Pratt & Whitney Rocketdyne (PWR) utilized a Space Act Agreement to test an oxygen/methane engine system in the Summer of 2010. PWR provided a 5,500 lbf (24,465 N) LOX/LCH4 regenerative cycle engine to demonstrate advanced thrust chamber assembly hardware and to evaluate the performance characteristics of the system. The chamber designs offered alternatives to traditional regenerative engine designs with improvements in cost and/or performance. MSFC provided the test stand, consumables and test personnel. The hot fire testing explored the effective cooling of one of the thrust chamber designs along with determining the combustion efficiency with variations of pressure and mixture ratio. The paper will summarize the status of these efforts.

  19. Modeling of the Evaporative Cooling of Running-Down Liquid Films in the Slit Channel of the Spraying Device of a Cooling Tower

    Science.gov (United States)

    Dashkov, G. V.; Malenko, G. L.; Solodukhin, A. D.; Tyutyuma, V. D.

    2014-11-01

    This paper presents the results of computational modeling of the nonstationary evaporative cooling of a liquid film running down a vertical surface cooled by a turbulent vapor-air counterflow. The heat and mass transfer problem has been formulated in conjugate form. The calculation data on the total heat flow density at the interface for various instants of time are given.

  20. Liquid nitrogen cooling considerations of the Compact Ignition Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Dabiri, A.E.

    1986-10-01

    A simple model was developed to estimate the cooldown time between pulses of toroidal field (TF) coils of the Compact Ignition Tokamak (CIT) using liquid nitrogen. Good agreement was obtained between the analysis results and those measured in the early fusion experimental devices. A cooldown time of about 1 h would reduce the TF coil temperature to about 80 K. An R and D experimental program is required to determine the actual cooldown time between pulses, an issue in the conceptual design of the CIT.

  1. Thermal profile analysis of Doubly-Fed induction generator based wind power converter with air and liquid cooling methods

    DEFF Research Database (Denmark)

    Zhou, Dao; Blaabjerg, Frede; Lau, Mogens

    2013-01-01

    Today, wind power generation system keeps on moving from onshore to offshore and also upscaling in size. As the lifetime of the wind power converter is prolonged to 20–25 years, this paper will investigate and compare different cooling methods for power modules — the air cooling and the liquid...... cooling seen from a thermal profile assessment point of view. Firstly, an analytical approach from loss profile to thermal profile for the power semiconductor is proposed and verified in a 2 MW Doubly-Fed Induction Generator (DFIG) based wind turbine system. Then, the typical air cooling and liquid...... cooling in wind power converter are analyzed and compared in terms of the mean junction temperature and the junction temperature fluctuation. It is concluded that the liquid cooling approach has a similar junction temperature fluctuation but gives a lower mean junction temperature than the air cooling...

  2. New method for vitrifying water and other liquids by rapid cooling of their aerosols

    Science.gov (United States)

    Mayer, Erwin

    1985-07-01

    A method for the vitrification of pure liquid water and dilute aqueous solutions is described which is the only one without a liquid cryomedium for heat transfer: rapid cooling of aqueous aerosol droplets on a solid cryoplate. This method is not limited to water and aqueous solutions, but can be used for the vitrification of any liquid aerosol, the only impurity being some codeposited vapor. The method can be applied in diverse fields such as cryobiology, cryomicroscopy, and low-temperature spectroscopy of water and dilute aqueous solutions to avoid the formation of crystalline ice.

  3. Mathematical Model-Based Temperature Preparation of Liquid-Propellant Components Cooled by Liquid Nitrogen in the Heat Exchanger with a Coolant

    Directory of Open Access Journals (Sweden)

    S. K. Pavlov

    2014-01-01

    Full Text Available Before fuelling the tanks of missiles, boosters, and spacecraft with liquid-propellant components (LPC their temperature preparation is needed. The missile-system ground equipment performs this operation during prelaunch processing of space-purpose missiles (SPM. Usually, the fuel cooling is necessary to increase its density and provide heat compensation during prelaunch operation of SPM. The fuel temperature control systems (FTCS using different principles of operation and types of coolants are applied for fuel cooling.To determine parameters of LPC cooling process through the fuel heat exchange in the heat exchanger with coolant, which is cooled by liquid nitrogen upon contact heat exchange in the coolant reservoir, a mathematical model of this process and a design technique are necessary. Both allow us to determine design parameters of the cooling system and the required liquid nitrogen reserve to cool LPC to the appropriate temperature.The article presents an overview of foreign and domestic publications on cooling processes research and implementation using cryogenic products such as liquid nitrogen. The article draws a conclusion that it is necessary to determine the parameters of LPC cooling process through the fuel heat exchange in the heat exchanger with coolant, which is liquid nitrogen-cooled upon contact heat exchange in the coolant reservoir allowing to define rational propellant cooling conditions to the specified temperature.The mathematical model describes the set task on the assumption that a heat exchange between the LPC and the coolant in the heat exchanger and with the environment through the walls of tanks and pipelines of circulation loops is quasi-stationary.The obtained curves allow us to calculate temperature changes of LPC and coolant, cooling time and liquid nitrogen consumption, depending on the process parameters such as a flow rate of liquid nitrogen, initial coolant temperature, pump characteristics, thermal

  4. Fail-safe system for activity cooled supersonic and hypersonic aircraft. [using liquid hydrogen fuel

    Science.gov (United States)

    Jones, R. A.; Braswell, D. O.; Richie, C. B.

    1975-01-01

    A fail-safe-system concept was studied as an alternative to a redundant active cooling system for supersonic and hypersonic aircraft which use the heat sink of liquid-hydrogen fuel for cooling the aircraft structure. This concept consists of an abort maneuver by the aircraft and a passive thermal protection system (TPS) for the aircraft skin. The abort manuever provides a low-heat-load descent from normal cruise speed to a lower speed at which cooling is unnecessary, and the passive TPS allows the aircraft skin to absorb the abort heat load without exceeding critical skin temperature. On the basis of results obtained, it appears that this fail-safe-system concept warrants further consideration, inasmuch as a fail-safe system could possibly replace a redundant active cooling system with no increase in weight and would offer other potential advantages.

  5. A pump driving liquid cooling circuit method for the aperture of an infrared cold optical system

    Science.gov (United States)

    Xie, RongJian

    2017-06-01

    To enhance the optical recognition and wavelength filtering of an infrared cold optical system, some lens need to be maintained within a certain temperature range, which requires specific thermal management of the aperture. A 250K liquid cooling circuit designed for this purpose is introduced, and the experimental results established and operated in a vacuum environmental simulation chamber is carried out and analyzed. A practical cooling power source of radiation cooling equipment is adopted and the sun exposure heat load is imitated by array of planar membrane heaters attached on the specific designed structure of the aperture. Controlling the aperture temperature and improving the optical system performance are proved effective. Numerical optimization of the cooling circuit and simulation of the aperture are performed , and the factors affect the optical system performance in the mean time are also investigated.

  6. Progress on the Liquid Hydrogen Absorber for the MICE Cooling Channel

    CERN Document Server

    Cummings, M A C

    2005-01-01

    This report describes the progress made on the design of the liquid hydrogen absorber for the international Muon Ionization Cooling Experiment (MICE). The absorber consists of a 21-liter vessel that contains liquid hydrogen (1.5 kg) or liquid helium (2.63 kg). The cryogen vessel is within the warm bore of the superconducting focusing magnet for the MICE. The purpose of the magnet is to provide a low beam beta region within the absorber. For safety reasons, the vacuum vessel for the hydrogen absorber is separated from the vacuum vessel for the superconducting magnet and the vacuum that surrounds the RF cavities or the detector. The absorber has two 300 mm-diameter thin aluminum windows. The vacuum vessel around the absorber has a pair of thin aluminum windows that separate the absorber vacuum space from adjacent vacuum spaces. The absorber will be cooled down using a heat exchanger that is built into the absorber walls. Liquid nitrogen is used to cool the absorber to 80 K. Liquid helium completes the absorber ...

  7. The boson peak of deeply cooled confined water reveals the existence of a low-temperature liquid-liquid crossover

    Science.gov (United States)

    Cupane, Antonio; Fomina, Margarita; Schirò, Giorgio

    2014-11-01

    The Boson peak of deeply cooled water confined in the pores of a silica xerogel is studied by inelastic neutron scattering at different hydration levels to separate the contributions from matrix, water on the pore surfaces and "internal" water. Our results reveal that at high hydration level, where the contribution from internal water is dominant, the temperature dependence of the Boson peak intensity shows an inflection point at about 225 K. The complementary use of differential scanning calorimetry to describe the thermodynamics of the system allows identifying the inflection point as the signature of a water liquid-liquid crossover.

  8. Research and Development Roadmaps for Liquid Metal Cooled Fast Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Kim, T. K. [Argonne National Lab. (ANL), Argonne, IL (United States); Grandy, C. [Argonne National Lab. (ANL), Argonne, IL (United States); Natesan, K. [Argonne National Lab. (ANL), Argonne, IL (United States); Sienicki, J. [Argonne National Lab. (ANL), Argonne, IL (United States); Hill, R. [Argonne National Lab. (ANL), Argonne, IL (United States)

    2017-04-20

    The United States Department of Energy (DOE) commissioned the development of technology roadmaps for advanced (non-light water reactor) reactor concepts to help focus research and development funding over the next five years. The roadmaps show the research and development needed to support demonstration of an advanced (non-LWR) concept by the early 2030s, consistent with DOE’s Vision and Strategy for the Development and Deployment of Advanced Reactors. The intent is only to convey the technical steps that would be required to achieve such a goal; the means by which DOE will determine whether to invest in specific tasks will be treated separately. The starting point for the roadmaps is the Technical Readiness Assessment performed as part of an Advanced Test and Demonstration Reactor study released in 2016. The roadmaps were developed based upon a review of technical reports and vendor literature summarizing the technical maturity of each concept and the outstanding research and development needs. Critical path tasks for specific systems were highlighted on the basis of time and resources needed to complete the tasks and the importance of the system to the performance of the reactor concept. The roadmaps are generic, i.e. not specific to a particular vendor’s design but vendor design information may have been used as representative of the concept family. In the event that both near-term and more advanced versions of a concept are being developed, either a single roadmap with multiple branches or separate roadmaps for each version were developed. In each case, roadmaps point to a demonstration reactor (engineering or commercial) and show the activities that must be completed in parallel to support that demonstration in the 2030-2035 window. This report provides the roadmaps for two fast reactor concepts, the Sodium-cooled Fast Reactor (SFR) and the Lead-cooled Fast Reactor (LFR). The SFR technology is mature enough for commercial demonstration by the early 2030s

  9. Advances in liquid metal cooled ADS systems, and useful results for the design of IFMIF

    Energy Technology Data Exchange (ETDEWEB)

    Massaut, V.; Debruyn, D. [SCK CEN, Mol (Belgium); Decreton, M. [Ghent Univ., Dept. of Applied Physics (Belgium)

    2007-07-01

    Full text of publication follows: Liquid metal cooled Accelerator Driven Systems (ADS) have a lot of design commonalities with the design of IFMIF. The use of a powerful accelerator and a liquid metal spallation source makes it similar to the main features of the IFMIF irradiator. Developments in the field of liquid metal ADS can thus be very useful for the design phase of IFMIF, and synergy between both domains should be enhanced to avoid dubbing work already done. The liquid metal ADS facilities are developed for testing materials under high fast (> 1 MeV) neutron flux, and also for studying the transmutation of actinides as foreseen in the P and T (Partitioning and Transmutation) strategy of future fission industry. The ADS are mostly constituted of a sub-critical fission fuel assembly matrix, a spallation source (situated at the centre of the fuel arrangement) and a powerful accelerator targeting the spallation source. In liquid metal ADS, the spallation source is a liquid metal (like Pb-Bi) which is actively cooled to remove the power generated by the particle beam, spallation reactions and neutrons. Based on an advanced ADS design (e.g. the MYRRHA/XT-ADS facility), the paper shows the various topics which are common for both facilities (ADS and IFMIF) and highlights their respective specificities, leading to focused R and D activities. This would certainly cover the common aspects related to high power accelerators, liquid metal targets and beam-target coupling. But problems of safety, radioprotection, source heating and cooling, neutrons shielding, etc... lead also to common features and developments. Results already obtained for the ADS development will illustrate this synergy. This paper will therefore allow to take profit of recent developments in both fission and fusion programs and enhance the collaboration among the R and D teams in both domains. (authors)

  10. Simulation of parameters of the vapor-liquid compression cooling system of power machines

    Science.gov (United States)

    Karelin, D. L.

    2017-09-01

    The paper presents a mathematical model of the cooling system with vapor-liquid compression installation modified with an additional allowance for the effect of mass flow rate of ambient air on a heat transfer in the system’s heat exchanger-condenser. Also the correction factors considering the difference between the mean log and the mean arithmetic temperature pressure are introduced. The results of numerical simulation showed that the efficiency of the proposed cooling system is 149% and 200% higher than the classical at the ambient temperature plus 10°C and 50°C respectively.

  11. Modeling of cooling channel flow in liquid-propellant rocket engines

    OpenAIRE

    Pizzarelli, Marco

    2008-01-01

    Ever since the development of liquid rocket engine, there has been a need to predict the peak heat flux that affects the engine material and thus to control the wall thermal behavior of rocket engine. To prevent thermal failure, the engine is generally cooled by means of a coolant that flows in passages that line the hottest part of the engine (i.e., combustion chamber and nozzle wall). This is the fluid-cooling system. If the coolant is one of the propellants, once it passes through th...

  12. PERFORMANCE EVALUATION OF CEILING RADIANT COOLING SYSTEM IN COMPOSITE CLIMATE

    Energy Technology Data Exchange (ETDEWEB)

    Sharma, Anuj [Malaviya National Institute of Technology (MNIT), Jaipur, India; Mathur, Jyotirmay [Malaviya National Institute of Technology (MNIT), Jaipur, India; Bhandari, Mahabir S [ORNL

    2015-01-01

    Radiant cooling systems are proving to be an energy efficient solution due to higher thermal capacity of cooling fluid especially for the buildings that require individual zone controls and where the latent loads are moderate. The Conventional air conditioners work at very low temperature i.e.5-8 c (refrigerant evaporator inlet) while the radiant cooling systems, also referred as high temperature cooling system, work at high temperatures i.e. 14-18 c. The radiant cooling systems can maintain lower MRT (Mean Radiant Temperature) as ceiling panels maintain uniform temperature gradient inside room and provide higher human comfort. The radiant cooling systems are relatively new systems and their operation and energy savings potential are not quantified for a large number of buildings and operational parameters. Moreover, there are only limited numbers of whole building simulation studies have been carried out for these systems to have a full confidence in the capability of modelling tools to simulate these systems and predict the impact of various operating parameters. Theoretically, savings achieve due to higher temperature set point of chilled water, which reduces chiller-running time. However, conventional air conditioner runs continuously to maintain requisite temperature. In this paper, experimental study for performance evaluation of radiant cooling system carried out on system installed at Malaviya National Institute of Technology Jaipur. This paper quantifies the energy savings opportunities and effective temperature by radiant cooling system at different chilled water flow rates and temperature range. The data collected/ analysed through experimental study will used for calibration and validation of system model of building prepared in building performance simulation software. This validated model used for exploring optimized combinations of key parameters for composite climate. These optimized combinations will used in formulation of radiant cooling system

  13. Evaluation Tool of Climate Potential for Ventilative Cooling

    DEFF Research Database (Denmark)

    Belleri, Annamaria; Psomas, Theofanis Ch.; Heiselberg, Per Kvols

    2015-01-01

    . Within IEA Annex 62 project, national experts are working on the development of a climate evaluation tool, which aims at assessing the potential of ventilative cooling by taking into account also building envelope thermal properties, internal gains and ventilation needs. The analysis is based on a single......The new initiatives and regulations towards nearly zero energy buildings forces designers to exploit the cooling potential of the climate to reduce the overheating occurrence and to improve thermal comfort indoors. Climate analysis is particularly useful at early design stages to support decision...... making towards cost-effective passive cooling solution e.g. ventilative cooling. As buildings with different use patterns, envelope characteristics and internal loads level do not follow equally the external climate condition, the climate analysis cannot abstract from building characteristics and use...

  14. Transient state study of electric motor heating and phase change solid-liquid cooling

    Energy Technology Data Exchange (ETDEWEB)

    Bellettre, J.; Sartre, V.; Lallemand, A. [Centre National de la Recherche Scientifique (CNRS), Centre de Thermique de Lyon, Villeurbanne, 69 (France); Biais, F. [AUXILEC, Chatou, 78 (France)

    1997-01-01

    This study reports on modelling of an autosynchronous electric motor stator, operating at transient state. The developed model, of the modal type, includes around 20 nodes. The simulations showed that hot spots are localized on the winding heads and led to the choice of a solid-liquid phase change cooling system. The comparison between simulation and experiment permitted the identification of unknown parameters. The model gives a good accuracy during steady-state and in the rising temperature phase. The modelling of the phase change cooling is realized by the addition of two nodes. The sensitivity analysis to PCM properties shows that the hot spot temperature decreases with increasing conductivities, inertia and latent heat of melting of the PCM and with decreasing melting temperature. Gallium (metal melting at 30{sup o}C) is the best PCM for the cooling of hot spots and P116 paraffin is the best non-metallic PCM. (author)

  15. Coolant and ambient temperature control for chillerless liquid cooled data centers

    Energy Technology Data Exchange (ETDEWEB)

    Chainer, Timothy J.; David, Milnes P.; Iyengar, Madhusudan K.; Parida, Pritish R.; Simons, Robert E.

    2017-08-29

    Cooling control methods and systems include measuring a temperature of air provided to one or more nodes by an air-to-liquid heat exchanger; measuring a temperature of at least one component of the one or more nodes and finding a maximum component temperature across all such nodes; comparing the maximum component temperature to a first and second component threshold and comparing the air temperature to a first and second air threshold; and controlling a proportion of coolant flow and a coolant flow rate to the air-to-liquid heat exchanger and the one or more nodes based on the comparisons.

  16. Interfacial tension in cooled heterogeneous liquid acetonitrile-ethyl acetate-isopropanol-water-phenol systems

    Science.gov (United States)

    Rudakov, O. B.; Khorokhordina, E. A.; Preobrazhenskii, M. A.

    2017-04-01

    It is found that the tension at the interfacial boundary of liquid phases formed by mixtures of acetonitrile-ethyl acetate-isopropanol (85 : 15 : 0 and 80 : 15 : 5 vol/vol/vol %) and water at 263 K falls exponentially as the concentration of phenols grows within 0-1 mg/mL. It is shown that the relatively low values of interfacial tension (11-32 mN/m) observed in cooled heterogeneous systems promote the redistribution of phenols between two liquid phases.

  17. Design and simulation of liquid cooled system for power battery of PHEV

    Science.gov (United States)

    Wang, Jianpeng; Xu, Haijun; Xu, Xiaojun; Pan, Cunyun

    2017-09-01

    Various battery chemistries have different responses to failure, but the most common failure mode of a cell under abusive conditions is the generation of heat and gas. To prevent battery thermal abuse, a battery thermal management system is essential. An excellent design of battery thermal management system can ensure that the battery is working at a suitable temperature and keeps the battery temperature diffenence at 2-3 °C. This paper presents a thermal-elcetric coupling model for a 37Ah lithium battery using AMESim. A liquid cooled system of hybrid electric vehicle power battery is designed to control the battery temperature.A liquid cooled model of thermal management system is built using AMESim, the simulation results showed that the temperature difference within 3°C of cell in the pack.

  18. Development of an enhanced liquid for electronic cooling

    Science.gov (United States)

    Mossaz, S.; Gruss, J. A.; Poncelet, O.; Berne, P.

    2014-07-01

    Development of NEPCM (Nanoparticle Encapsulated Phase Change Material) nanofluids using low melting temperature metals is a very pertinent area of research in the context of effective thermal management solutions. Compared to a pure fluid, these nanofluids have a higher heat capacity during the phase change and it is possible to improve the heat transfer, as a result of this phase change. To appreciate the merits, in terms of energy, an energy Performance Evaluation Criteria (PEC) has been defined as the ratio of heat transfer rate at fixed pumping power. The numerical results obtained show an improvement around 20% of this energetic criterion at low ΔT compared to the base fluid. A status of the development of these fluids in our laboratory is given in this paper. From an experimental point of view, a specific test loop has been developed in order to test thermo hydraulic performance in a controlled manner in laminar and turbulent conditions at imposed heat flux with a small volume of fluid (350 ml). The test loop was validated with pure water and the choice of materials used has been defined but not yet tested.

  19. Double-Sided Liquid Cooling for Power Semiconductor Devices Using Embedded Power Technology

    OpenAIRE

    Charboneau, Bryan Charles

    2005-01-01

    Power electronics is a constantly growing and demanding technical field. Consumer demand and developing technologies have made the improvement of power density a primary emphasis of research for this area. Power semiconductors present some of the major challenges for increasing system level power density due to high loss density and interconnection requirements. Advanced cooling schemes, such as double-sided, forced liquid convection or multi-phase flow, can be implemented with non-wire bo...

  20. A low-cost-solar liquid desiccant system for residential cooling

    Science.gov (United States)

    Ware, Joel D., III

    The use of liquid desiccants for dehumidification of heating, ventilation, and air conditioning (HVAC) process air is becoming a more promising concept as the drive for energy conservation continues to grow. Recently, liquid desiccant systems have been implemented on the commercial level in conjunction with evaporative coolers and have recorded energy savings upwards of 50%. The aim of this research is to test the potential liquid desiccant systems have on the residential level when paired with a conventional vapor compression cycle and to construct a system that would overcome some of its barriers to the residential market. A complete low-cost-solar liquid desiccant system was designed, constructed, and tested in the Off-Grid Zero Emissions Building (OGZEB) at the Florida State University. Key design characteristics include turbulent process air flow through the conditioner and airside heating in the regenerator. The system was tested in the two following ways: (1) for the energy savings while maintaining a constant temperature over a twenty four hour period and (2) for the energy savings over a single cooling cycle. The liquid desiccant system achieved a maximum energy savings of 38% over a complete day and 52% over a single cooling cycle. It was projected that the system has the potential to save 1064 kWh over the course of a year. When combined with a renewable source of heat for regeneration, liquid desiccant systems become very cost effective. The levelized cost of energy for the combination of the liquid desiccant system and solar thermal collectors was calculated to be 7.06 C/kWh with a payback period of 4.4 years. This research provides evidence of the technology's potential on the residential sector and suggests ways for it to become competitive in the market.

  1. Feasibility and economic evaluation of low-cost evaporative cooling ...

    African Journals Online (AJOL)

    A fixed operating air flow rate of 4.3 kg- 1 was used to evaluate cooling performance and energy efficiency ratio of the cooler. The results showed that the indoor dry bulb temperature significantly (P < 0.001) drops parallel with a significant (P < 0.001) rise in relative humidity during storage. The energy efficiency ratio ...

  2. Performance of a 10-kJ SMES model cooled by liquid hydrogen thermo-siphon flow for ASPCS study

    Science.gov (United States)

    Makida, Y.; Shintomi, T.; Hamajima, T.; Ota, N.; Katsura, M.; Ando, K.; Takao, T.; Tsuda, M.; Miyagi, D.; Tsujigami, H.; Fujikawa, S.; Hirose, J.; Iwaki, K.; Komagome, T.

    2015-12-01

    We propose a new electrical power storage and stabilization system, called an Advanced Superconducting Power Conditioning System (ASPCS), which consists of superconducting magnetic energy storage (SMES) and hydrogen energy storage, converged on a liquid hydrogen station for fuel cell vehicles. A small 10- kJ SMES system, in which a BSCCO coil cooled by liquid hydrogen was installed, was developed to create an experimental model of an ASPCS. The SMES coil is conductively cooled by liquid hydrogen flow through a thermo-siphon line under a liquid hydrogen buffer tank. After fabrication of the system, cooldown tests were carried out using liquid hydrogen. The SMES coil was successfully charged up to a nominal current of 200 A. An eddy current loss, which was mainly induced in pure aluminum plates pasted onto each pancake coils for conduction cooling, was also measured.

  3. An experimental investigation of liquid methane convection and boiling in rocket engine cooling channels

    Science.gov (United States)

    Trujillo, Abraham Gerardo

    In the past decades, interest in developing hydrocarbon-fueled rocket engines for deep spaceflight missions has continued to grow. In particular, liquid methane (LCH4) has been of interest due to the weight efficiency, storage, and handling advantages it offers over several currently used propellants. Deep space exploration requires reusable, long life rocket engines. Due to the high temperatures reached during combustion, the life of an engine is significantly impacted by the cooling system's efficiency. Regenerative (regen) cooling is presented as a viable alternative to common cooling methods such as film and dump cooling since it provides improved engine efficiency. Due to limited availability of experimental sub-critical liquid methane cooling data for regen engine design, there has been an interest in studying the heat transfer characteristics of the propellant. For this reason, recent experimental studies at the Center for Space Exploration Technology Research (cSETR) at the University of Texas at El Paso (UTEP) have focused on investigating the heat transfer characteristics of sub-critical CH4 flowing through sub-scale cooling channels. To conduct the experiments, the csETR developed a High Heat Flux Test Facility (HHFTF) where all the channels are heated using a conduction-based thermal concentrator. In this study, two smooth channels with cross sectional geometries of 1.8 mm x 4.1 mm and 3.2 mm x 3.2 mm were tested. In addition, three roughened channels all with a 3.2 mm x 3.2 mm square cross section were also tested. For the rectangular smooth channel, Reynolds numbers ranged between 68,000 and 131,000, while the Nusselt numbers were between 40 and 325. For the rough channels, Reynolds numbers ranged from 82,000 to 131,000, and Nusselt numbers were between 65 and 810. Sub-cooled film-boiling phenomena were confirmed for all the channels presented in this work. Film-boiling onset at Critical Heat Flux (CHF) was correlated to a Boiling Number (Bo) of

  4. Progress on the MICE Liquid Absorber Cooling and Cryogenic Distribution System

    CERN Document Server

    Green, Michael; Bradshaw, Thomas W; Cummings, M A C; Drumm, Paul V; Ishimoto, Shigeru; Ivanyushenkov, Yury; Lau, Wing; Yang, Stephanie

    2005-01-01

    This report describes the progress made on the design of the liquid hydrogen absorber for the international Muon Ionization Cooling Experiment (MICE). The absorber consists of a 21-liter vessel that contains liquid hydrogen (1.5 kg) or liquid helium (2.63 kg). The cryogen vessel is within the warm bore of the superconducting focusing magnet for the MICE. The purpose of the magnet is to provide a low beam beta region within the absorber. For safety reasons, the vacuum vessel for the hydrogen absorber is separated from the vacuum vessel for the superconducting magnet and the vacuum that surrounds the RF cavities or the detector. The absorber has two 300 mm-diameter thin aluminum windows. The vacuum vessel around the absorber has a pair of thin aluminum windows that separate the absorber vacuum space from adjacent vacuum spaces. Because the muon beam in MICE is of low intensity, there is no beam heating in the absorber. As a result, the absorber can be cooled using a single 4 K cooler. This report describes prog...

  5. Ice Pack Heat Sink Subsystem - Phase I. [astronaut liquid cooling garment design and testing

    Science.gov (United States)

    Roebelen, G. J., Jr.

    1973-01-01

    This paper describes the design and test at one-g of a functional laboratory model (non-flight) Ice Pack Heat Sink Subsystem to be used eventually for astronaut cooling during manned space missions. In normal use, excess heat in the liquid cooling garment (LCG) coolant is transferred to a reusable/regenerable ice pack heat sink. For emergency operation, or for extension of extravehicular activity mission time after all the ice has melted, water from the ice pack is boiled to vacuum, thereby continuing to remove heat from the LCG coolant. This subsystem incorporates a quick connect/disconnect thermal interface between the ice pack heat sink and the subsystem heat exchanger.

  6. Cooling process of liquid propellant rocket by means of kerosene-alumina nanofluid

    Directory of Open Access Journals (Sweden)

    Mostafa Mahmoodi

    2016-12-01

    Full Text Available Heat transfer augmentation of kerosene-alumina nanofluid is studied for the possible use in the regenerative cooling channel of semi cryogenic engine. The basic partial differential equations are reduced to ordinary differential equations which are solved using differential transformation method. Velocity and temperature profiles as well as the skin friction coefficient and Nusselt number are determined. The influence of pertinent parameters such as nanofluid volume fraction, viscosity parameter and Eckert number on the flow and heat transfer characteristics is discussed. The results indicate that adding alumina into the fuel of liquid rocket engine (kerosene can be considered as the way of enhancing cooling process of chamber and nozzle walls. Nusselt number is an increasing function of viscosity parameter and nanoparticle volume fraction while it is a decreasing function of Eckert number.

  7. Method for forming a liquid cooled airfoil for a gas turbine

    Science.gov (United States)

    Grondahl, Clayton M.; Willmott, Leo C.; Muth, Myron C.

    1981-01-01

    A method for forming a liquid cooled airfoil for a gas turbine is disclosed. A plurality of holes are formed at spaced locations in an oversized airfoil blank. A pre-formed composite liquid coolant tube is bonded into each of the holes. The composite tube includes an inner member formed of an anti-corrosive material and an outer member formed of a material exhibiting a high degree of thermal conductivity. After the coolant tubes have been bonded to the airfoil blank, the airfoil blank is machined to a desired shape, such that a portion of the outer member of each of the composite tubes is contiguous with the outer surface of the machined airfoil blank. Finally, an external skin is bonded to the exposed outer surface of both the machined airfoil blank and the composite tubes.

  8. Feasibility analysis of two-phase MHD energy conversion for liquid metal cooled reactors

    Energy Technology Data Exchange (ETDEWEB)

    Wu Qiao [Department of Nuclear Engineering and Radiation Health Physics, Oregon State University, Corvallis, OR 97331 (United States)], E-mail: qiao@engr.orst.edu; Schubring, DuWayne L. [Department of Nuclear Engineering and Radiation Health Physics, Oregon State University, Corvallis, OR 97331 (United States); Sienicki, James J. [Reactor Engineering Division, Argonne National Laboratory, Argonne, IL 60439 (United States)

    2007-11-15

    A two-phase MHD energy conversion unit is proposed to a liquid metal cooled fast reactor. Using supercritical CO{sub 2} as the working fluid in the gas cycle without considering friction and heat losses, the optimized cycles efficiency is obtained, which is about 5% higher than that of the gas turbine Brayton cycle with the same regenerator/compressor configurations. Based on a simple MHD power analysis and the two-phase homogeneous flow model, the important system operational conditions were estimated. The results suggest that a liquid lead pump of at least 20% of the MHD power output is needed in order to convert the 400 MW reactor heat into electricity at the specified thermal efficiency, unless a mixture foam flow of void fraction greater than 80% is achievable at very high mixture velocity.

  9. Formation of metastabil liquid phases in the isotonic solution of sodium cloraide during cooling

    Directory of Open Access Journals (Sweden)

    A. T. Ходько

    2016-07-01

    Full Text Available In this paper the cooling process cryomicroscopy of 0.15 M of isotonic sodium chloride solution was conducted. It was shown that there is liquidliquid phase change before the crystallization process. As a result, the coarse system (highly concentrated emulsion was formed. The dispersed phase and the disperse medium in a binary system with the same qualitative chemical composition differ in concentration. Therefore, the greater is the volume ratio of the coexisting phases, the greater is the difference in their quantitative compositions. The dispersed phase, that composes the main volume in the system under investigation, should have lower NaCl concentration than the disperse medium and the initial solution. In this case it will be hypotonic (and disperse medium – hypertonic in relation to cytoplasm of human internal environment. This physical-chemical factor, which hasn’t been considered previously, might be responsible for osmotic damage in living cells during cryopreservation of cell suspensions.

  10. Development of preliminary design program for combustor of regenerative cooled liquid rocket engine

    Science.gov (United States)

    Cho, Won Kook; Seol, Woo Seok; Son, Min; Seo, Min Kyo; Koo, Jaye

    2011-10-01

    An integrated program was established to design a combustor for a liquid rocket engine and to analyze regenerative cooling results on a preliminary design level. Properties of burnt gas from a kerosene-LOx mixture in the combustor and rocket performance were calculated from CEA which is the code for the calculation of chemical equilibrium. The heat transfer of regenerative cooling was analyzed by using SUPERTRAPP code for coolant properties and by one-dimensional correlations of the heat transfer coefficient from the combustor liner to the coolant. Profiles of the combustors of F-1 and RS-27A engines were designed from similar input data and the present results were compared to actual data for validation. Finally, the combustors of 30 tonf class, 75 tonf class and 150 tonf class were designed from the required thrust, combustion chamber, exit pressure and mixture ratio of propellants. The wall temperature, heat flux and pressure drop were calculated for heat transfer analysis of regenerative cooling using the profiles.

  11. Innovative radiation-based direct heat exchanger (DHX) for liquid metal cooled reactors

    Energy Technology Data Exchange (ETDEWEB)

    De Santis, Andrea, E-mail: andrea.desantis@uniroma1.it [“SAPIENZA” University of Rome, DIAEE, Corso Vittorio Emanuele II 244, 00186 Rome (Italy); Vitale Di Maio, Damiano; Caruso, Gianfranco [“SAPIENZA” University of Rome, DIAEE, Corso Vittorio Emanuele II 244, 00186 Rome (Italy); Manni, Fabio [S.R.S. Servizi di Ricerche e Sviluppo S.r.l., Rome (Italy)

    2013-10-15

    Highlights: • An innovative DHRS for liquid metal fast breeder reactors has been proposed. • A parametric CFD analyses of the DHX performances have been performed. • A comparison between SFR and LFR applications has been performed. -- Abstract: Considering the importance of safety features in the development of Generation IV nuclear reactors, an innovative and passive decay heat removal system (DHRS) has been proposed for liquid metal cooled reactors. The attention is here focused on the direct heat exchanger (DHX) of the system constituted by a bayonet tube that allows to remove the decay heat from the primary coolant; both primary and secondary fluids flow in natural circulation. Since each bayonet tube is equipped with a vacuum gap, the most important heat transfer mechanism characterizing the DHX is radiation. Furthermore, the presence of the vacuum gap guarantees a physical separation and a complete decoupling between primary and secondary fluids, enhancing the safety features of the whole system. Several CFD analyses have been carried out in order to obtain a characterization of the DHX both for sodium and lead cooled fast reactors, in order to optimize the DHX geometry on the basis of the specific application, and the results are discussed in the paper.

  12. Experiments on FTU with an actively water cooled liquid lithium limiter

    Energy Technology Data Exchange (ETDEWEB)

    Mazzitelli, G., E-mail: giuseppe.mazzitelli@enea.it [Associazione EURATOM-ENEA sulla Fusione, C.R. Frascati, C.P. 65-00044 Frascati, Rome (Italy); Apicella, M.L.; Apruzzese, G.; Crescenzi, F.; Iannone, F.; Maddaluno, G. [Associazione EURATOM-ENEA sulla Fusione, C.R. Frascati, C.P. 65-00044 Frascati, Rome (Italy); Pericoli-Ridolfini, V. [Associazione EURATOM-ENEA sulla Fusione, CREATE, Università di Napoli Federico II, 80125 Napoli (Italy); Roccella, S.; Reale, M.; Viola, B. [Associazione EURATOM-ENEA sulla Fusione, C.R. Frascati, C.P. 65-00044 Frascati, Rome (Italy); Lyublinski, I.; Vertkov, A. [JSC “RED STAR”, Moscow (Russian Federation)

    2015-08-15

    In order to prevent the overheating of the liquid Li surface and the consequent Li evaporation for T > 500 °C, an advanced version of the liquid lithium limiter has been realized and installed on FTU. This new system, named Cooled Lithium Limiter (CLL), has been optimized to demonstrate the lithium limiter capability to sustain thermal loads as high as 10 MW/m{sup 2} with up to 5 s of plasma pulse duration. The CLL operates with an actively cooled system with water circulation at the temperature of about 200 °C, for heating lithium up to the melting point and for the heat removal during the plasma discharges. To characterize CLL during discharges, a fast infrared camera and the spectroscopic signals from Li and D atom emission have been used. The experiments analyzed so far and simulated by ANSYS code, point out that heat loads as high as 2 MW/m{sup 2} for 1.5 s have been withstood without problems.

  13. A Method Based on Radiative Cooling for Detecting Structural Changes in Undercooled Metallic Liquids

    Science.gov (United States)

    Rulison, Aaron J.; Rhim, Won-Kyu

    1995-01-01

    We introduce a structure-sensitive parameter for undercooled melts which can be measured in containerless processing experiments. We have established that the ratio, R(T), of hemispherical total emissivity epsilon(sub T)(T) to constant-pressure specific heat c(sub p)(T) can serve as an indicator which is sensitive to any changes in short range atomic order in undercooled metallic melts. R(T) (triple bonds) epsilon(sub T)(T)/c(sub p)(T) values for nickel, zirconium, and silicon have been obtained using the high temperature electrostatic levitator while the levitated melts were undergoing purely radiative cooling into the deeply undercooled region. R(T) plots for undercooled liquid nickel and zirconium indicate no significant change in short-range structure from their melting temperatures to 15% undercooling. In contrast, liquid silicon shows marked short-range structural changes beginning above its melting temperature and extending throughout the undercooled region. The short-range structure of liquid silicon is related to the highly-directional covalent bonding which characterizes its solid form. The nickel and zirconium data show that epsilon(sub T) varies linearly with T, in support of metal emissivity theories.

  14. Technical Evaluation of Side Stream Filtration for Cooling Towers

    Energy Technology Data Exchange (ETDEWEB)

    None

    2012-10-01

    Cooling towers are an integral component of many refrigeration systems, providing comfort or process cooling across a broad range of applications. Cooling towers represent the point in a cooling system where heat is dissipated to the atmosphere through evaporation. Cooling towers are commonly used in industrial applications and in large commercial buildings to release waste heat extracted from a process or building system through evaporation of water.

  15. An alternative solution for heavy liquid metal cooled reactors fuel assemblies

    Energy Technology Data Exchange (ETDEWEB)

    Vitale Di Maio, Damiano, E-mail: damiano.vitaledimaio@uniroma1.it [“SAPIENZA” University of Rome – DIAEE, Corso Vittorio Emanuele II, 244, 00186 Rome (Italy); Cretara, Luca; Giannetti, Fabio [“SAPIENZA” University of Rome – DIAEE, Corso Vittorio Emanuele II, 244, 00186 Rome (Italy); Peluso, Vincenzo [“ENEA”, Via Martiri di Monte Sole 4, 40129 Bologna (Italy); Gandini, Augusto [“SAPIENZA” University of Rome – DIAEE, Corso Vittorio Emanuele II, 244, 00186 Rome (Italy); Manni, Fabio [“SRS Engineering Design S.r.l.”, Vicolo delle Palle 25-25/b, 00186 Rome (Italy); Caruso, Gianfranco [“SAPIENZA” University of Rome – DIAEE, Corso Vittorio Emanuele II, 244, 00186 Rome (Italy)

    2014-10-15

    Highlights: • A new fuel assembly locking system for heavy metal cooled reactor is proposed. • Neutronic, mechanical and thermal-hydraulic evaluations of the system behavior have been performed. • A comparison with other solutions has been presented. - Abstract: In the coming future, the electric energy production from nuclear power plants will be provided by both thermal reactors and fast reactors. In order to have a sustainable energy production through fission reactors, fast reactors should provide an increasing contribution to the total electricity production from nuclear power plants. Fast reactors have to achieve economic and technical targets of Generation IV. Among these reactors, Sodium cooled Fast Reactors (SFRs) and Lead cooled Fast Reactors (LFRs) have the greatest possibility to be developed as industrial power plants within few decades. Both SFRs and LFRs require a great R and D effort to overcome some open issues which affect the present designs (e.g. sodium-water reaction for the SFRs, erosion/corrosion for LFRs, etc.). The present paper is mainly focused on LFR fuel assembly (FA) design: issues linked with the high coolant density of lead or lead–bismuth eutectic cooled reactors have been investigated and an innovative solution for the core mechanical design is here proposed and analyzed. The solution, which foresees cylindrical fuel assemblies and exploits the buoyancy force due to the lead high density, allows to simplify the FAs locking system, to reduce their length and could lead to a more uniform neutron flux distribution.

  16. Annular core liquid-salt cooled reactor with multiple fuel and blanket zones

    Science.gov (United States)

    Peterson, Per F.

    2013-05-14

    A liquid fluoride salt cooled, high temperature reactor having a reactor vessel with a pebble-bed reactor core. The reactor core comprises a pebble injection inlet located at a bottom end of the reactor core and a pebble defueling outlet located at a top end of the reactor core, an inner reflector, outer reflector, and an annular pebble-bed region disposed in between the inner reflector and outer reflector. The annular pebble-bed region comprises an annular channel configured for receiving pebble fuel at the pebble injection inlet, the pebble fuel comprising a combination of seed and blanket pebbles having a density lower than the coolant such that the pebbles have positive buoyancy and migrate upward in said annular pebble-bed region toward the defueling outlet. The annular pebble-bed region comprises alternating radial layers of seed pebbles and blanket pebbles.

  17. Vacuum Plasma Spray Forming of Copper Alloy Liners for Regeneratively Cooled Liquid Rocket Combustion Chambers

    Science.gov (United States)

    Zimmerman, Frank

    2003-01-01

    Vacuum plasma spray (VPS) has been demonstrated as a method to form combustion chambers from copper alloys NARloy-Z and GRCop-84. Vacuum plasma spray forming is of particular interest in the forming of CuCrNb alloys such as GRCop-84, developed by NASA s Glenn Research Center, because the alloy cannot be formed using conventional casting and forging methods. This limitation is related to the levels of chromium and niobium in the alloy, which exceed the solubility limit in copper. Until recently, the only forming process that maintained the required microstructure of CrNb intermetallics was powder metallurgy formation of a billet from powder stock, followed by extrusion. This severely limits its usefulness in structural applications, particularly the complex shapes required for combustion chamber liners. This paper discusses the techniques used to form combustion chambers from CuCrNb and NARloy-Z, which will be used in regeneratively cooled liquid rocket combustion chambers.

  18. Comparison of three MHD flow control methods for self-cooled liquid metal blankets

    Energy Technology Data Exchange (ETDEWEB)

    Walker, J.S.; Picologlou, B.F.

    1986-01-01

    The heat deposition in a blanket is concentrated near the first wall. Uniform liquid-metal velocity in a self-cooled blanket is unattractive, because it leads to low mixed-mean temperature rise through the blanket and reduced power conversion efficiency. The objective of MHD flow control is to use the electromagnetic forces to produce a non-uniform velocity distribution which gives a uniform temperature distribution over the thickness of the blanket. Three methods of MHD flow control are presented here and the MHD pressure drops corresponding to the three methods are compared. One of the methods, although successful at achieving nonuniform velocity profiles, permits a large circulation of electric current which produces a high pressure drop. The analytical results do not indicate a clear choice between the other two methods. The analytical results do point to possible difference in heat transfer performance with the two methods.

  19. Evaluation of gas cooling for pressurized phosphoric acid fuel cell stacks

    Science.gov (United States)

    Farooque, M.; Skok, A. J.; Maru, H. C.; Kothmann, R. E.; Harry, R. W.

    1983-01-01

    Gas cooling is a more reliable, less expensive and a more simple alternative to conventional liquid cooling for heat removal from the phosphoric acid fuel cell (PAFC). The feasibility of gas cooling has already been demonstrated in atmospheric pressure stacks. This paper presents theoretical and experimental investigation of gas cooling for pressurized PAFC. Two approaches to gas cooling, Distributed Gas Cooling (DIGAS) and Separated Gas Cooling (SGC) were considered, and a theoretical comparison on the basis of cell performance indicated SGC to be superior to DIGAS. The feasibility of SGC was experimentally demonstrated by operating a 45-cell stack for 700 hours at pressure, and determining thermal response and the effect of other related parameters.

  20. ANTEO+: A subchannel code for thermal-hydraulic analysis of liquid metal cooled systems

    Energy Technology Data Exchange (ETDEWEB)

    Lodi, F., E-mail: francesco.lodi5@unibo.it [DIN – Laboratory of Montecuccolino, University of Bologna, Via dei Colli 16, 40136 Bologna (Italy); Grasso, G., E-mail: giacomo.grasso@enea.it [ENEA (Italian National Agency for New Technologies, Energy and Sustainable Economic Development), via Martiri di Monte Sole, 4, 40129 Bologna (Italy); Mattioli, D., E-mail: davide.mattioli@enea.it [ENEA (Italian National Agency for New Technologies, Energy and Sustainable Economic Development), via Martiri di Monte Sole, 4, 40129 Bologna (Italy); Sumini, M., E-mail: marco.sumini@unibo.it [DIN – Laboratory of Montecuccolino, University of Bologna, Via dei Colli 16, 40136 Bologna (Italy)

    2016-05-15

    Highlights: • The code structure is presented in detail. • The performed validation is outlined. • Results are critically discussed assessing code accuracy. • Conclusions are drawn and ground for future work identified. - Abstract: Liquid metal cooled fast reactors are promising options for achieving the high degrees of safety and sustainability demanded by the Generation IV paradigm. Among the critical aspects to be addressed in the design process, thermal-hydraulics is one of the most challenging; in order to embed safety in the core conceptualization, these aspects are to be considered at the very beginning of the design process, and translated in a design perspective. For achieving these objectives the subchannel code ANTEO+ has been conceived, able to simulate pin bundle arrangements cooled by liquid metals. The main purposes of ANTEO+ are simplifying the problem description maintaining the required accuracy, enabling a more transparent interface with the user, and having a clear and identifiable application domain, in order to help the user interpreting the results and, mostly, defining their confidence. Since ANTEO+ relies on empirical correlations, the validation phase is of paramount importance along with a clear discussion on the simplifications adopted in modeling the conservation equations. In the present work a detailed description of ANTEO+ structure is given along with a thorough validation of the main models implemented for flow split, pressure drops and subchannel temperatures. The analysis confirmed the ability of ANTEO+ in reproducing experimental data in its anticipated validity domain, with a relatively high degree of accuracy when compared to other classical subchannel tools like ENERGY-II, COBRA-IV-I-MIT and BRS-TVS.

  1. Weakly doped InP layers prepared by liquid phase epitaxy using a modulated cooling rate

    Science.gov (United States)

    Krukovskyi, R.; Mykhashchuk, Y.; Kost, Y.; Krukovskyi, S.; Saldan, I.

    2017-04-01

    Epitaxial structures based on InP are widely used to manufacture a number of devices such as microwave transistors, light-emitting diodes, lasers and Gunn diodes. However, their temporary instability caused by heterogeneity of resistivity along the layer thickness and the influence of various external or internal factors prompts the need for the development of a new reliable technology for their preparation. Weak doping by Yb, Al and Sn together with modulation of the cooling rate applied to prepare InP epitaxial layers is suggested to be adopted within the liquid phase epitaxy (LPE) method. The experimental results confirm the optimized conditions created to get a uniform electron concentration in the active n-InP layer. A sharp profile of electron concentration in the n+-InP(substrate)/n-InP/n+-InP epitaxial structure was observed experimentally at the proposed modulated cooling rate of 0.3 °С-1.5 °С min-1. The proposed technological method can be used to control the electrical and physical properties of InP epitaxial layers to be used in Gunn diodes.

  2. Advanced gas cooled nuclear reactor materials evaluation and development program

    Energy Technology Data Exchange (ETDEWEB)

    1977-01-01

    Results of work performed from January 1, 1977 through March 31, 1977 on the Advanced Gas Cooled Nuclear Reactor Materials Evaluation and Development Program are presented. The objectives of this program are to evaluate candidate alloys for Very High Temperature Reactor (VHTR) Process Heat and Direct Cycle Helium Turbine (DCHT) applications, in terms of the effect of simulated reactor primary coolant (impure Helium), high temperatures, and long time exposures, on the mechanical properties and structural and surface stability of selected candidate alloys. A second objective is to select and recommend materials for future test facilities and more extensive qualification programs. Work covered in this report includes progress to date on alloy selection for VHTR Nuclear Process Heat (NPH) applications and for DCHT applications. The present status on the simulated reactor helium loop design and on designs for the testing and analysis facilities and equipment is discussed.

  3. Helium-Cooled Refractory Alloys First Wall and Blanket Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Wong, C.P.C.; Nygren, R.E.; Baxi, C.B.; Fogarty, P.; Ghoniem, N.; Khater, H.; McCarthy, K.; Merrill, B.; Nelson, B.; Reis, E.E.; Sharafat, S.; Schleicher, R.; Sze, D.K.; Ulrickson, M.; Willms, S.; Youssef, M.; Zinkel, S.

    1999-08-01

    Under the APEX program the He-cooled system design task is to evaluate and recommend high power density refractory alloy first wall and blanket designs and to recommend and initiate tests to address critical issues. We completed the preliminary design of a helium-cooled, W-5Re alloy, lithium breeder design and the results are reported in this paper. Many areas of the design were assessed, including material selection, helium impurity control, and mechanical, nuclear and thermal hydraulics design, and waste disposal, tritium and safety design. System study results show that at a closed cycle gas turbine (CCGT) gross thermal efficiency of 57.5%, a superconducting coil tokamak reactor, with an aspect ratio of 4, and an output power of 2 GWe, can be projected to have a cost of electricity at 54.6 mill/kWh. Critical issues were identified and we plan to continue the design on some of the critical issues during the next phase of the APEX design study.

  4. DEVELOPMENT AND FIELD EVALUATION OF LIQUID ...

    African Journals Online (AJOL)

    ACSS

    2016-02-26

    Feb 26, 2016 ... DEVELOPMENT AND FIELD EVALUATION OF LIQUID INOCULANTS WITH NATIVE. Bradyrhizobial STRAINS ... on peanut (Arachis hypogaea L.) production under field conditions at Córdoba province in Argentina. The efficient N fixing ..... are adapted to local ecological conditions. (Svenning et al., 2001; ...

  5. Design of Cooling Channels of Preburners for Small Liquid Rocket Engines with Computational Flow and Heat Transfer Analysis

    Directory of Open Access Journals (Sweden)

    Insang Moon

    2011-09-01

    Full Text Available A series of computational analyses was performed to predict the cooling process by the cooling channel of preburners used for kerosene-liquid oxygen staged combustion cycle rocket engines. As an oxygen-rich combustion occurs in the kerosene fueled preburner, it is of great importance to control the wall temperature so that it does not exceed the critical temperature. However, since the heat transfer is proportional to the speed of fluid running inside the channel, the high heat transfer leads to a trade-off of pressure loss. For this reason, it is necessary to establish a certain criteria between the pressure loss and the heat transfer or the wall surface temperature. The design factors of the cooling channel were determined by the computational research, and a test model was manufactured. The test model was used for the hot fire tests to prove the function of the cooling mechanism, among other purposes.

  6. Pilot-scale cooling tower to evaluate corrosion, scaling, and biofouling control strategies for cooling system makeup water.

    Science.gov (United States)

    Chien, S H; Hsieh, M K; Li, H; Monnell, J; Dzombak, D; Vidic, R

    2012-02-01

    Pilot-scale cooling towers can be used to evaluate corrosion, scaling, and biofouling control strategies when using particular cooling system makeup water and particular operating conditions. To study the potential for using a number of different impaired waters as makeup water, a pilot-scale system capable of generating 27,000 kJ∕h heat load and maintaining recirculating water flow with a Reynolds number of 1.92 × 10(4) was designed to study these critical processes under conditions that are similar to full-scale systems. The pilot-scale cooling tower was equipped with an automatic makeup water control system, automatic blowdown control system, semi-automatic biocide feeding system, and corrosion, scaling, and biofouling monitoring systems. Observed operational data revealed that the major operating parameters, including temperature change (6.6 °C), cycles of concentration (N = 4.6), water flow velocity (0.66 m∕s), and air mass velocity (3660 kg∕h m(2)), were controlled quite well for an extended period of time (up to 2 months). Overall, the performance of the pilot-scale cooling towers using treated municipal wastewater was shown to be suitable to study critical processes (corrosion, scaling, biofouling) and evaluate cooling water management strategies for makeup waters of complex quality.

  7. Evaluation of two cooling systems under a firefighter coverall

    NARCIS (Netherlands)

    Teunissen, L.P.J.; Wang, L.C.; Chou, S.N.; Huang, C.; Jou, G.T.; Daanen, H.A.M.

    2014-01-01

    Firemen often suffer from heat strain. This study investigated two chest cooling systems for use under a firefighting suit. In nine male subjects, a vest with water soaked cooling pads and a vest with water perfused tubes were compared to a control condition. Subjects performed 30 min walking and 10

  8. An experimental investigation on liquid methane heat transfer enhancement through the use of longitudinal fins in cooling channels

    Science.gov (United States)

    Galvan, Manuel de Jesus

    In the past years, hydrocarbon fuels have been the focus of attention as the interest in developing reusable, high-performing liquid rocket engines has grown. Liquid methane (LCH4) has been of particular interest because of the cost, handling, and storage advantages that it presents when compared to currently used propellants. Deep space exploration requires thrusters that can operate reliably during long-duration missions. One of the challenges in the development of a reliable engine has been providing adequate combustion chamber cooling to prevent engine failure. Regenerative (regen) cooling has presented itself as an appealing option because it provides improved cooling and engine efficiency over other types of cooling, such as film or dump cooling. Due to limited availability of experimental sub-critical liquid methane cooling data for pressure-fed regen engine design, there has been an interest in studying the heat transfer characteristics of the propellant. For this reason, recent experimental studies at the Center for Space Exploration Technology Research (cSETR) at the University of Texas at El Paso (UTEP) have focused on investigating the heat transfer characteristics of sub-critical CH4 flowing through smooth sub-scale cooling channels. In addition to investigating smooth channels, the cSETR has conducted experiments to investigate the effects of internal longitudinal fins on the heat transfer of methane. To conduct the experiments, the cSETR developed a conduction-based thermal concentrator known as the High Heat Flux Test Facility (HHFTF) in which the channels are heated. In this study, a smooth channel and three channels with longitudinal fins all with cross sectional geometries of 3.2 mm x 3.2 mm were tested. The Nusselt numbers ranged from 70 and 510, and Reynolds numbers were between 50,000 and 128,000. Sub-cooled film-boiling phenomena were discovered in the data pertaining to the smooth and two finned channels. Sub-cooled film-boiling was not

  9. Experimentally Determined Overall Heat Transfer Coefficients for Spacesuit Liquid Cooled Garments

    Science.gov (United States)

    Bue, Grant; Rhodes, Richard; Anchondo, Ian; Westheimer, David; Campbell, Colin; Vogel, Matt; Vonaue, Walt; Conger, Bruce; Stein, James

    2015-01-01

    A Human-In-The-Loop (HITL) Portable Life Support System 2.0 (PLSS 2.0) test has been conducted at NASA Johnson Space Center in the PLSS Development Laboratory from October 27, 2014 to December 19, 2014. These closed-loop tests of the PLSS 2.0 system integrated with human subjects in the Mark III Suit at 3.7 psi to 4.3 psi above ambient pressure performing treadmill exercise at various metabolic rates from standing rest to 3000 BTU/hr (880 W). The bulk of the PLSS 2.0 was at ambient pressure but effluent water vapor from the Spacesuit Water Membrane Evaporator (SWME) and the Auxiliary Membrane Evaporator (Mini-ME), and effluent carbon dioxide from the Rapid Cycle Amine (RCA) were ported to vacuum to test performance of these components in flight-like conditions. One of the objectives of this test was to determine the overall heat transfer coefficient (UA) of the Liquid Cooling Garment (LCG). The UA, an important factor for modeling the heat rejection of an LCG, was determined in a variety of conditions by varying inlet water temperature, flow rate, and metabolic rate. Three LCG configurations were tested: the Extravehicular Mobility Unit (EMU) LCG, the Oceaneering Space Systems (OSS) LCG, and the OSS auxiliary LCG. Other factors influencing accurate UA determination, such as overall heat balance, LCG fit, and the skin temperature measurement, will also be discussed.

  10. Spectroscopic measurements of lithium influx from an actively water-cooled liquid lithium limiter on FTU

    Energy Technology Data Exchange (ETDEWEB)

    Apruzzese, G.M., E-mail: gerarda.apruzzese@enea.it; Apicella, M.L.; Maddaluno, G.; Mazzitelli, G.; Viola, B.

    2017-04-15

    Since 2006, experiments using a liquid lithium limiter (LLL) were successfully performed on FTU, pointing out the problem of the quantity of lithium in the plasma, especially in conditions of strong evaporation due to the high temperature of limiter surface. In order to avoid the strong evaporation it is necessary to control the temperature by removing the heat from the limiter during the plasma exposure. To explore this issue a new actively cooled lithium limiter (CLL) has been installed and tested in FTU. Suitable monitors to detect the presence of lithium in the plasma are the spectroscopic diagnostics in the visible range that permit to measure the flux of lithium, coming from the limiter surface, through the brightness of the LiI spectral lines. For this aim an Optical Multichannel Analyser (OMA) spectrometer and a single wavelength impurities monitor have been used. The analysis of the Li influx signals has permitted to monitor the effects of interaction between the plasma and the limiter connected to the thermal load. Particular attention has been paid on the possible occurrence of sudden rise of the signals, which is an index of a strong interaction that could lead to a disruption. On the other hand, the appearance of significant signals gives useful indication if the interaction with the plasma has taken place.

  11. Evaluating the income and employment impacts of gas cooling technologies

    Energy Technology Data Exchange (ETDEWEB)

    Hughes, P.J. [Oak Ridge National Lab., TN (United States); Laitner, S.

    1995-03-01

    The purpose of this study is to estimate the potential employment and income benefits of the emerging market for gas cooling products. The emphasis here is on exports because that is the major opportunity for the U.S. heating, ventilating, and air-conditioning (HVAC) industry. But domestic markets are also important and considered here because without a significant domestic market, it is unlikely that the plant investments, jobs, and income associated with gas cooling exports would be retained within the United States. The prospects for significant gas cooling exports appear promising for a variety of reasons. There is an expanding need for cooling in the developing world, natural gas is widely available, electric infrastructures are over-stressed in many areas, and the cost of building new gas infrastructure is modest compared to the cost of new electric infrastructure. Global gas cooling competition is currently limited, with Japanese and U.S. companies, and their foreign business partners, the only product sources. U.S. manufacturers of HVAC products are well positioned to compete globally, and are already one of the faster growing goods-exporting sectors of the U.S. economy. Net HVAC exports grew by over 800 percent from 1987 to 1992 and currently exceed $2.6 billion annually (ARI 1994). Net gas cooling job and income creation are estimated using an economic input-output model to compare a reference case to a gas cooling scenario. The reference case reflects current policies, practices, and trends with respect to conventional electric cooling technologies. The gas cooling scenario examines the impact of accelerated use of natural gas cooling technologies here and abroad.

  12. Effects of liquid cooling garments on recovery and performance time in individuals performing strenuous work wearing a firefighter ensemble.

    Science.gov (United States)

    Kim, Jung-Hyun; Coca, Aitor; Williams, W Jon; Roberge, Raymond J

    2011-07-01

    This study investigated the effects of body cooling using liquid cooling garments (LCG) on performance time (PT) and recovery in individuals wearing a fully equipped prototype firefighter ensemble (PFE) incorporating a self-contained breathing apparatus (SCBA). Six healthy male participants (three firefighters and three non-firefighters) completed six experimental sessions in an environmental chamber (35°C, 50% relative humidity), consisting of three stages of 15 min exercise at 75% VO2max, and 10 min rest following each exercise stage. During each session, one of the following six conditions was administered in a randomized order: control (no cooling, CON); air ventilation of exhaust SCBA gases rerouted into the PFE (AV); top cooling garment (TCG); TCG combined with AV (TCG+AV); a shortened whole body cooling garment (SCG), and SCG combined with AV (SCG+AV). Results showed that total PT completed was longer under SCG and SCG+AV compared with CON, AV, TCG, and TCG+AV (pAV>TCG=TCG+AV>SCG>SCG+AV) without a statistical difference between the conditions (prest and prolongs performance time in subsequent bouts of exercise. LCG also appears to be an effective method for body cooling that promotes heat dissipation during uncompensable heat stress.

  13. Modeling Single-Phase and Boiling Liquid Jet Impingement Cooling in Power Electronics

    Energy Technology Data Exchange (ETDEWEB)

    Narumanchi, S. V. J.; Hassani, V.; Bharathan, D.

    2005-12-01

    Jet impingement has been an attractive cooling option in a number of industries over the past few decades. Over the past 15 years, jet impingement has been explored as a cooling option in microelectronics. Recently, interest has been expressed by the automotive industry in exploring jet impingement for cooling power electronics components. This technical report explores, from a modeling perspective, both single-phase and boiling jet impingement cooling in power electronics, primarily from a heat transfer viewpoint. The discussion is from the viewpoint of the cooling of IGBTs (insulated-gate bipolar transistors), which are found in hybrid automobile inverters.

  14. Evaluating the usability of a commercial cooling vest in the Hong Kong industries.

    Science.gov (United States)

    Chan, Albert P; Yang, Yang; Song, Wen-Fang

    2017-02-28

    The provision of appropriate personal cooling vests is recognized as an effective measure to combat heat stress. However, personal cooling vests are not widely implemented in the Hong Kong industries. The current study aims to evaluate the usability of a hybrid cooling vest that is associated with the success of its application in industrial settings. A self-administrated questionnaire focusing on 10 subjective attributes of cooling effect, ergonomic design and usability of a hybrid cooling vest was administered with 232 occupational workers in the construction, horticultural and cleaning, airport apron services and kitchen and catering industries. A structural equation model estimated by analysis of moment structures was constructed to evaluate the usability of the cooling vest, as influenced by cooling effect and ergonomic design. Results showed that cooling effect (path coefficient = 0.69, p nature of the structural relationships among the subjective perceptions of personal cooling vests. The empirical findings furnish sound evidence for further optimization of the hybrid cooling vest in terms of cooling effect and ergonomic design for occupational workers.

  15. Economic evaluation of geothermal power generation, heating, and cooling

    Energy Technology Data Exchange (ETDEWEB)

    Kanoglu, Mehmet; Cengel, Yunus A. [Nevada Univ., Dept. of Mechanical Engineering, Reno, NV (United States)

    1999-06-01

    Economic analysis of a typical geothermal resource shows that potential revenues from geothermal heating or cooling can be much larger than those from power generation alone. Geothermal heating may generate up to about 3.1 times and geothermal absorption cooling 2.9 times as much revenue as power generation alone. Similarly, combined power generation and heating may generate about 2.1 times and combined power generation and cooling about 1.2 times as much revenue as power generation alone. Cost and payback period comparison appear to favor power generation, followed by district heating. (Author)

  16. Cooling of a multichip electronic module by means of confined two-dimensional jets of dielectric liquid

    Science.gov (United States)

    Wadsworth, D. C.; Mudawar, I.

    1990-11-01

    Experiments were performed to investigate single-phase heat transfer from a smooth 12.7 x 12.7-sq-mm simulated chip to a two-dimensional jet of dielectric FC-72 liquid issuing from a thin rectangular slot into a channel confined between the chip surface and nozzle plate. The effects of jet width, confinement channel height, and impingement velocity have been examined. Channel height had a negligible effect on the heat-transfer performance of the jet. A correlation for the convective heat-transfer coefficient is presented as a function of jet width, heater length, flow velocity, and fluid properties. A self-contained multichip cooling module consisting of a 3 x 3 array of heat sources confirmed the uniformity and predictability of cooling for each of the nine chips, and proved the cooling module is well suited for packaging large arrays of high-power-density chips.

  17. Engineering studies to support a liquid sodium cooled pebble bed target/blanket for an accelerator breeder

    Energy Technology Data Exchange (ETDEWEB)

    Cooper, K.C.; Malenfant, R.E.

    1977-01-01

    Preliminary calculations on using a liquid sodium cooled pebble bed of thorium metal for the target and blanket of a particle accelerator to convert fertile material to fissile have indicated the concept has considerable merit. Fuel management is simple and continuous on-line feed is effected. Additional features include excellent heat transfer, low pressure drop, minimization of structures and enhanced safety. Promising features strongly suggest that the work be continued to further refine the studies. Although specific to the target and blanket of the accelerator breeder concept, the work is readily extended to a high efficiency liquid metal cooled nuclear reactor employing a pebble bed as the fuel. 10 refs., 4 figs., 1 tab.

  18. Evaluation of liquid ingestion after bariatric surgery

    Directory of Open Access Journals (Sweden)

    Roberto Oliveira Dantas

    2011-03-01

    Full Text Available CONTEXT: Bariatric surgery is an effective treatment for obesity; however, after surgery the patient may have difficulty in swallowing liquid and solid foods. OBJECTIVES: To evaluate liquid ingestion in patients who had undergone bariatric surgery. METHOD: We studied 43 volunteers with normal body mass index (BMI (BMI: 18.5-24.9 kg/m², 55 subjects with class III obesity (BMI: >40.0 kg/m², and 48 subjects with bariatric surgery for treatment of class III obesity. The method chosen for evaluation was the water swallowing test. The subjects drank in triplicate 50 mL of water while being precisely timed and the number of swallows were counted. RESULTS: There was no difference between subjects with normal BMI and subjects with class III obesity. During the first 2 months after bariatric surgery the patients showed an increase in the time needed to drink the entire volume, in the number of swallows, and in the inter-swallow interval, and a decrease in the volume swallowing capacity (volume/swallowing and swallowing flow rate (volume swallowed/second. After 2 months, the results of the swallowing measurements moved in the direction of normal values. CONCLUSION: Bariatric surgery may cause more intense alterations of liquid bolus swallowing within 2 months after the procedure, which moved to normal values after this time.

  19. Heat pipe radiation cooling evaluation: Task 2 concept studies report

    Energy Technology Data Exchange (ETDEWEB)

    Silverstein, C.C.

    1991-10-01

    This report presents the result of Task 2, Concept Studies for Heat Pipe Radiation Cooling (HPRC), which was performed for Los Alamos National Laboratory under Contract 9-XT1-U9567. Studies under a prior contract defined a reference HPRC conceptual design for hypersonic aircraft engines operating at Mach 5 and an altitude of 80,000 ft. Task 2 involves the further investigation of heat pipe radiation cooling (HPRC) systems for additional design and operating conditions.

  20. Evaluation of Active Cooling Systems for Non-Residential Buildings

    Directory of Open Access Journals (Sweden)

    M.A. Othuman Mydin

    2014-05-01

    Full Text Available Cooling systems are an essential element in many facets of modern society including cars, computers and buildings. Cooling systems are usually divided into two types: passive and active. Passive cooling transfers heat without using any additional energy while active cooling is a type of heat transfer that uses powered devices such as fans or pumps. This paper will focus on one particular type of passive cooling: air-conditioning systems. An air-conditioning system is defined as controlled air movement, temperature, humidity and cleanliness of a building area. Air conditioning consists of cooling and heating. Therefore, the air-conditioning system should be able to add and remove heat from the area. An air-conditioning system is defined as a control or treatment of air in a confined space. The process that occurs is the air-conditioning system absorbs heat and dust while, at the same time, cleaning the air breathed into a closed space. The purpose of air-conditioning is to maintain a comfortable atmosphere for human life and to meet user requirements. In this paper, air-conditioning systems for non-residential buildings will be presented and discussed.

  1. Traction Drive Inverter Cooling with Submerged Liquid Jet Impingement on Microfinned Enhanced Surfaces (Presentation)

    Energy Technology Data Exchange (ETDEWEB)

    Waye, S.; Narumanchi, S.; Moreno, G.

    2014-09-01

    Jet impingement is one means to improve thermal management for power electronics in electric-drive traction vehicles. Jet impingement on microfin-enhanced surfaces further augments heat transfer and thermal performance. A channel flow heat exchanger from a commercial inverter was characterized as a baseline system for comparison with two new prototype designs using liquid jet impingement on plain and microfinned enhanced surfaces. The submerged jets can target areas with the highest heat flux to provide local cooling, such as areas under insulated-gate bipolar transistors and diode devices. Low power experiments, where four diodes were powered, dissipated 105 W of heat and were used to validate computational fluid dynamics modeling of the baseline and prototype designs. Experiments and modeling used typical automotive flow rates using water-ethylene glycol as a coolant (50%-50% by volume). The computational fluid dynamics model was used to predict full inverter power heat dissipation. The channel flow and jet impingement configurations were tested at full inverter power of 40 to 100 kW (output power) on a dynamometer, translating to an approximate heat dissipation of 1 to 2 kW. With jet impingement, the cold plate material is not critical for the thermal pathway. A high-temperature plastic was used that could eventually be injection molded or formed, with the jets formed from a basic aluminum plate with orifices acting as nozzles. Long-term reliability of the jet nozzles and impingement on enhanced surfaces was examined. For jet impingement on microfinned surfaces, thermal performance increased 17%. Along with a weight reduction of approximately 3 kg, the specific power (kW/kg) increased by 36%, with an increase in power density (kW/L) of 12% compared with the baseline channel flow configuration.

  2. Theoretical prediction of the effect of heat transfer parameters on cooling rates of liquid-filled plastic straws used for cryopreservation of spermatozoa.

    Science.gov (United States)

    Sansinen, M; Santos, M V; Zaritzky, N; Baez, R; Chirife, J

    2010-01-01

    Heat transfer plays a key role in cryopreservation of liquid semen in plastic straws. The effect of several parameters on the cooling rate of a liquid-filled polypropylene straw when plunged into liquid nitrogen was investigated using a theoretical model. The geometry of the straw containing the liquid was assimilated as two concentric finite cylinders of different materials: the fluid and the straw; the unsteady-state heat conduction equation for concentric cylinders was numerically solved. Parameters studied include external (convection) heat transfer coefficient (h), the thermal properties of straw manufacturing material and wall thickness. It was concluded that the single most important parameter affecting the cooling rate of a liquid column contained in a straw is the external heat transfer coefficient in LN2. Consequently, in order to attain maximum cooling rates, conditions have to be designed to obtain the highest possible heat transfer coefficient when the plastic straw is plunged in liquid nitrogen.

  3. Assessment of external heat transfer coefficient during oocyte vitrification in liquid and slush nitrogen using numerical simulations to determine cooling rates.

    Science.gov (United States)

    Santos, M V; Sansinena, M; Zaritzky, N; Chirife, J

    2012-01-01

    In oocyte vitrification, plunging directly into liquid nitrogen favor film boiling and strong nitrogen vaporization. A survey of literature values of heat transfer coefficients (h) for film boiling of small metal objects with different geometries plunged in liquid nitrogen revealed values between 125 to 1000 W per per square m per K. These h values were used in a numerical simulation of cooling rates of two oocyte vitrification devices (open-pulled straw and Cryotop), plunged in liquid and slush nitrogen conditions. Heat conduction equation with convective boundary condition was considered a linear mathematical problem and was solved using the finite element method applying the variational formulation. COMSOL Multiphysics was used to simulate the cooling process of the systems. Predicted cooling rates for OPS and Cryotop when cooled at -196 degree C (liquid nitrogen) or -207 degree C (average for slush nitrogen) for heat transfer coefficients estimated to be representative of film boiling, indicated lowering the cooling temperature produces only a maximum 10 percent increase in cooling rates; confirming the main benefit of plunging in slush over liquid nitrogen does not arise from their temperature difference. Numerical simulations also demonstrated that a hypothetical four-fold increase in the cooling rate of vitrification devices when plunging in slush nitrogen would be explained by an increase in heat transfer coefficient. This improvement in heat transfer (i.e., high cooling rates) in slush nitrogen is attributed to less or null film boiling when a sample is placed in slush (mixture of liquid and solid nitrogen) because it first melts the solid nitrogen before causing the liquid to boil and form a film.

  4. A Film Cooling Model for a RP-1/GOX Staged Combustion Liquid Rocket Engine (Preprint)

    National Research Council Canada - National Science Library

    Haberlen, Philip A; Greisen, Daniel A; Anderson, William E

    2007-01-01

    .... An existing film cooling model was modified and applied to these experimental results. The resultant model predicted combustion chamber adiabatic wall temperature profiles for input propellant flow conditions and chamber geometry...

  5. An experimental investigation of the cooling channel geometry effects on the internal forced convection of liquid methane

    Science.gov (United States)

    Trejo, Adrian

    Rocket engine fuel alternatives have been an area of discussion for use in high performance engines and deep spaceflight missions. In particular, LCH4 has showed promise as an alternative option in regeneratively cooled rocket engines due to its non-toxic nature, similar storage temperatures to liquid oxygen, and its potential as an in situ resource. However, data pertaining to the heat transfer characteristics of LCH4 is limited. For this reason, a High Heat Transfer Test Facility (HHTTF) at the University of Texas at El Paso's (UTEP) Center for Space Exploration Technology and Research has been developed for the purpose of flowing LCH4 through several heated tube geometry designs subjected to a constant heat flux. In addition, a Methane Condensing Unit (MCU) is integrated to the system setup to supply LCH4 to the test facility. Through the use of temperature and pressure measurements, this experiment will serve not only to study the heat transfer characteristics of LCH4; it serves as a method of simulating the cooling channels of a regeneratively cooled rocket engine at a subscale level. The cross sections for the cooling channels investigated are a 1.8 mm x 1.8 mm square channel, 1.8 mm x 4.1 mm rectangular channel, 3.2 mm and 6.34 mm inside diameter channel, and a 1.8 mm x 14.2 mm high aspect ratio cooling channel (HARCC). The test facility is currently designed for test pressures between 1.03 MPa to 2.06 MPa and heat fluxes up to 5 MW/m2. Results show that at the given test pressures, the Reynolds number reaches up to 140,000 for smaller cooling channels (3.2 mm diameter tube and 1.8 mm x 4.1 mm rectangle) while larger cooling channel geometries (6.35 mm diameter and HARCC) reached Reynolds number around 70,000. Nusselt numbers reached as high as 320 and 265 for a 3.2 mm diameter tube and 1.8 mm x 4.1 mm rectangular channel respectively. For cooling channel geometries with 6.35 mm diameter and HARCC geometry, Nusselt numbers reached 136 (excluding an outlier

  6. Kilowatt-level direct-'refractive index matching liquid'-cooled Nd:YLF thin disk laser resonator.

    Science.gov (United States)

    Ye, Zhibin; Liu, Chong; Tu, Bo; Wang, Ke; Gao, Qingsong; Tang, Chun; Cai, Zhen

    2016-01-25

    A direct-liquid-cooled Nd:YLF thin disk laser resonator is presented, which features the use of refractive index matching liquid (RIML) as coolant. Highly uniform pump intensity distribution with rectangular shape is realized by using metallic planar waveguides. Much attention has been paid on the design of the gain module, including how to achieve excellent cooling ability with multi-channel coolers and how to choose the doping levels of the crystals for realizing well-distributed pump absorption. The flow velocity of the coolant is found to be a key parameter for laser performance and optimized to keep it in laminar flow status for dissipating unwanted heat load. A single channel device is used to measure the convective heat transfer coefficient (CHTC) at different flow velocities. Accordingly, the thermal stress in the disk is analyzed numerically and the maximum permissible thermal load is estimated. Experimentally, with ten pieces of a-cut Nd:YLF thin disks of different doping levels, a linear polarized laser with an average output power of 1120 W is achieved at the pump power of 5202 W, corresponding to an optical-optical efficiency of 21.5%, and a slope efficiency of 30.8%. Furthermore, the wavefront aberration of the gain module is measured to be quite weak, with a peak to valley (PV) value of 4.0 μm when it is pumped at 5202 W, which enables the feasibility of its application in an unstable resonator. To the best of our knowledge, this is the first demonstration of kilowatt-level direct-'refractive index matching liquid'-cooled Nd:YLF thin disk laser resonator.

  7. Field evaluation of performance of radiant heating/cooling ceiling panel system

    DEFF Research Database (Denmark)

    Li, Rongling; Yoshidomi, Togo; Ooka, Ryozo

    2015-01-01

    heating/coolingceiling panel system is used. However, no standard exists for the in situ performance evaluation of radiantheating/cooling ceiling systems; furthermore, no published database is available for comparison. Thus,this study aims to not only clarify the system performance but also to share our...... experience and our resultsfor them to serve as a reference for other similar projects. Here, the system performance in relation toits heating/cooling capacity and thermal comfort has been evaluated. The heat transfer coefficient fromwater to room was 3.7 W/(m2K) and 4.8 W/(m2K) for heating and cooling cases...

  8. Survey and evaluation of available thermal insulation materials for use on solar heating and cooling systems

    Energy Technology Data Exchange (ETDEWEB)

    1980-03-01

    This is the final report of a survey and evaluation of insulation materials for use with components of solar heating and cooling systems. The survey was performed by mailing questionnaires to manufacturers of insulation materials and by conducting an extensive literature search to obtain data on relevant properties of various types of insulation materials. The study evaluated insulation materials for active and passive solar heating and cooling systems and for multifunction applications. Primary and secondary considerations for selecting insulation materials for various components of solar heating and cooling systems are presented.

  9. Computational and experimental study on supersonic film cooling for liquid rocket nozzle applications

    Directory of Open Access Journals (Sweden)

    Vijayakumar Vishnu

    2015-01-01

    Full Text Available An experimental and computational investigation of supersonic film cooling (SFC was conducted on a subscale model of a rocket engine nozzle. A computational model of a convergent-divergent nozzle was generated, incorporating a secondary injection module for film cooling in the divergent section. Computational Fluid Dynamic (CFD simulations were run on the model and different injection configurations were analyzed. The CFD simulations also analyzed the parameters that influence film cooling effectiveness. Subsequent to the CFD analysis and literature survey an angled injection configuration was found to be more effective, therefore the hardware was fabricated for the same. The fabricated nozzle was later fixed to an Air-Kerosene combustor and numerous sets of experiments were conducted in order to ascertain the effect on film cooling on the nozzle wall. The film coolant employed was gaseous Nitrogen. The results showed substantial cooling along the walls and a considerable reduction in heat transfer from the combustion gas to the wall of the nozzle. Finally the computational model was validated using the experimental results. There was fairly good agreement between the predicted nozzle wall temperature and the value obtained through experiments.

  10. The Heat and Mass Transfer Processes at the Cooling of Strong Heated Sphere in a Cold Liquid

    Science.gov (United States)

    Puzina, Yu Yu

    2017-10-01

    Some new experimental results of continuum mechanics problems in two-phase systems are described. The processes of heat and mass transfer during cooling of strong heated sphere in the subcooled liquid are studied. Due to high level of heater temperature the stable vapor film is formed on the sphere surface. Calculation of steady-state transport processes at vapor – water interface is carried out using methods of molecular-kinetic theory. Heat transfer in vapor by thermal conductivity and natural convection in liquid are considered. Pressure balance is provided by hydrostatic pressure and non-equilibrium boundary condition. The results of the calculations are analyzed by comparison with previous data and experimental results.

  11. Liquid-cooled Ti:Sapphire thin disk amplifiers for high average power 100-TW systems.

    Science.gov (United States)

    Nagymihaly, R S; Cao, H; Papp, D; Hajas, G; Kalashnikov, M; Osvay, K; Chvykov, V

    2017-03-20

    In this work, numerical heat transfer simulations of direct water-cooled gain modules for thin disk (TD) Ti:Sapphire (Ti:Sa) power amplifiers are presented. By using the TD technique in combination with the extraction during pumping (EDP) method 100-TW class amplifiers operating around 300 W average power could be reached in the future. Single and double-sided cooling arrangements were investigated for several coolant flow velocities. Simulations which upscale the gain module for multiple kilowatts of average power were also performed for large aperture Ti:Sa disks and for multiple disks with several coolant channels.

  12. Monitoring system for a liquid-cooled nuclear fission reactor. [PWR

    Science.gov (United States)

    DeVolpi, A.

    1984-07-20

    The invention provides improved means for detecting the water levels in various regions of a water-cooled nuclear power reactor, viz., in the downcomer, in the core, in the inlet and outlet plenums, at the head, and elsewhere; and also for detecting the density of the water in these regions. The invention utilizes a plurality of exterior gamma radiation detectors and a collimator technique operable to sense separate regions of the reactor vessel to give respectively, unique signals for these regions, whereby comparative analysis of these signals can be used to advise of the presence and density of cooling water in the vessel.

  13. Ecotoxicological evaluation of magnetic ionic liquids.

    Science.gov (United States)

    Sintra, Tânia E; Nasirpour, Maryam; Siopa, Filipa; Rosatella, Andreia A; Gonçalves, Fernando; Coutinho, João A P; Afonso, Carlos A M; Ventura, Sónia P M

    2017-09-01

    Although magnetic ionic liquids (MILs) are not yet industrially applied, their continued development and eventual commercial use may lead to their appearance into the aquatic ecosystem through accidental spills or effluents, consequently promoting aquatic contaminations. Furthermore, the deficient information and uncertainty surrounding the environmental impact of MILs could be a major barrier to their widespread industrial application and international registration. Thus, in the present work, a range of cholinium salt derivatives with magnetic properties was synthesized and their ecotoxicity was evaluated towards the luminescent bacteria Vibrio fischeri. The results suggest that all MILs structures tested are moderately toxic, or even toxic, to the bacteria. Furthermore, their toxicity is highly dependent on the structural modifications of the cation, namely the alkyl side chain length and the number of hydroxyethyl groups, as well as the atomic number of the metal anion. Finally, from the magnetic anions evaluated, the [MnCl4](2-) is the less toxic. In order to improve the knowledge for the prospective design of environmentally safer MILs, it is important to expand this study to other aquatic organisms at different trophic levels. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. Numerical simulation of the heat transfer at cooling a high-temperature metal cylinder by a flow of a gas-liquid medium

    Science.gov (United States)

    Makarov, S. S.; Lipanov, A. M.; Karpov, A. I.

    2017-10-01

    The numerical modeling results for the heat transfer during cooling a metal cylinder by a gas-liquid medium flow in an annular channel are presented. The results are obtained on the basis of the mathematical model of the conjugate heat transfer of the gas-liquid flow and the metal cylinder in a two-dimensional nonstationary formulation accounting for the axisymmetry of the cooling medium flow relative to the cylinder longitudinal axis. To solve the system of differential equations the control volume approach is used. The flow field parameters are calculated by the SIMPLE algorithm. To solve iteratively the systems of linear algebraic equations the Gauss-Seidel method with under-relaxation is used. The results of the numerical simulation are verified by comparing the results of the numerical simulation with the results of the field experiment. The calculation results for the heat transfer parameters at cooling the high-temperature metal cylinder by the gas-liquid flow are obtained with accounting for evaporation. The values of the rate of cooling the cylinder by the laminar flow of the cooling medium are determined. The temperature change intensity for the metal cylinder is analyzed depending on the initial velocity of the liquid flow and the time of the cooling process.

  15. Comparison of heat transfer in liquid and slush nitrogen by numerical simulation of cooling rates for French straws used for sperm cryopreservation.

    Science.gov (United States)

    Sansinena, M; Santos, M V; Zaritzky, N; Chirife, J

    2012-05-01

    Slush nitrogen (SN(2)) is a mixture of solid nitrogen and liquid nitrogen, with an average temperature of -207 °C. To investigate whether plunging a French plastic straw (commonly used for sperm cryopreservation) in SN(2) substantially increases cooling rates with respect to liquid nitrogen (LN(2)), a numerical simulation of the heat conduction equation with convective boundary condition was used to predict cooling rates. Calculations performed using heat transfer coefficients in the range of film boiling confirmed the main benefit of plunging a straw in slush over LN(2) did not arise from their temperature difference (-207 vs. -196 °C), but rather from an increase in the external heat transfer coefficient. Numerical simulations using high heat transfer (h) coefficients (assumed to prevail in SN(2)) suggested that plunging in SN(2) would increase cooling rates of French straw. This increase of cooling rates was attributed to a less or null film boiling responsible for low heat transfer coefficients in liquid nitrogen when the straw is placed in the solid-liquid mixture or slush. In addition, predicted cooling rates of French straws in SN(2) tended to level-off for high h values, suggesting heat transfer was dictated by heat conduction within the liquid filled plastic straw. Copyright © 2012 Elsevier Inc. All rights reserved.

  16. Failure detection of liquid cooled electronics in sealed packages. [in airborne information management system

    Science.gov (United States)

    Hoadley, A. W.; Porter, A. J.

    1991-01-01

    The theory and experimental verification of a method of detecting fluid-mass loss, expansion-chamber pressure loss, or excessive vapor build-up in NASA's Airborne Information Management System (AIMS) are presented. The primary purpose of this leak-detection method is to detect the fluid-mass loss before the volume of vapor on the liquid side causes a temperature-critical part to be out of the liquid. The method detects the initial leak after the first 2.5 pct of the liquid mass has been lost, and it can be used for detecting subsequent situations including the leaking of air into the liquid chamber and the subsequent vapor build-up.

  17. Direct Evaporatrive Coolers of Gases and Liquids with Lowered Limit of Cooling

    Directory of Open Access Journals (Sweden)

    Doroshenko A.V.

    2015-12-01

    Full Text Available We have developed main technical solutions solution of indirect evaporative water and air coolers with reduced cooling limit. Packed part of heat-mass transfer devices is made of the film type based monoblock compositions of polymer materials. A mathematical model describing the processes of joint heat and mass transfer in evaporative coolers is executed. A comparative analysis of the possibilities of coolers designed based on experimental data on the efficiency of processes of heat and mass transfer.

  18. Performance evaluation of ejector expansion combined cooling and power cycles

    Science.gov (United States)

    Ghaebi, Hadi; Rostamzadeh, Hadi; Matin, Pouria Seyed

    2017-09-01

    This paper studies performance characteristics of a basic ejector expansion combined cooling and power cycle (EECCPC) as well as three modified ones. These modified cycles are EECCPC incorporating turbine bleeding, regenerative EECCP cycle, and EECCP cycle incorporating with both turbine bleeding and regeneration. The expansion valve has been replaced by a two-phase ejector-expander in the traditional CCP cycle to improve the first and second-law efficiencies. Furthermore, the exergy destruction for components of the systems as well as the whole systems has been calculated, leading to determination of the main source of irreversibility in different cycles. The results of the exergy analysis reveals that the generator has the major contribution role in the overall losses of the systems. The results also show that the EECCP cycle surpasses the TCCP cycle in terms of thermal and exergy efficiencies. As a matter of fact, the thermal and exergy efficiencies are improved by 6.02, and 5.44%, respectively, throughout this successive modification. At last, sensitivity analysis of different key parameters on performance of the cycles has been investigated. It is shown that one can obtain higher thermal efficiency by increasing of the generator and evaporator temperatures or decreasing of the condenser temperature.

  19. Low-enrichment and long-life Scalable LIquid Metal cooled small Modular (SLIMM-1.2) reactor

    Energy Technology Data Exchange (ETDEWEB)

    El-Genk, Mohamed S., E-mail: mgenk@unm.edu [Institute for Space and Nuclear Power Studies, University of New Mexico, Albuquerque, NM (United States); Nuclear Engineering Department, University of New Mexico, Albuquerque, NM (United States); Mechanical Engineering Department, University of New Mexico, Albuquerque, NM (United States); Chemical and Biological Engineering Department, University of New Mexico, Albuquerque, NM (United States); Palomino, Luis M.; Schriener, Timothy M. [Institute for Space and Nuclear Power Studies, University of New Mexico, Albuquerque, NM (United States); Nuclear Engineering Department, University of New Mexico, Albuquerque, NM (United States)

    2017-05-15

    Highlights: • Developed low enrichment and natural circulation cooled SLIMM-1.2 SMR for generating 10–100 MW{sub th}. • Neutronics analyses estimate operation life and temperature reactivity feedback. • At 100 MW{sub th}, SLIMM-1.2 operates for 6.3 FPY without refueling. • SLIMM-1.2 has relatively low power peaking and maximum UN fuel temperature < 1400 K. - Abstract: The Scalable LIquid Metal cooled small Modular (SLIMM-1.0) reactor with uranium nitride fuel enrichment of 17.65% had been developed for generating 10–100 MW{sub th} continuously, without refueling for ∼66 and 5.9 full power years, respectively. Natural circulation of in-vessel liquid sodium (Na) cools the core of this fast energy spectrum reactor during nominal operation and after shutdown, with the aid of a tall chimney and an annular Na/Na heat exchanger (HEX) of concentric helically coiled tubes. The HEX at the top of the downcomer maximizes the static pressure head for natural circulation. In addition to the independent emergency shutdown (RSS) and reactor control (RC), the core negative temperature reactivity feedback safely decreases the reactor thermal power, following modest increases in the temperatures of UN fuel and in-vessel liquid sodium. The decay heat is removed from the core by natural circulation of in-vessel liquid sodium, with aid of the liquid metal heat pipes laid along the reactor vessel wall, and the passive backup cooling system (BCS) using natural circulation of ambient air along the outer surface of the guard vessel wall. This paper investigates modifying the SLIMM-1.0 reactor design to lower the UN fuel enrichment. To arrive at a final reactor design (SLIMM-1.2), the performed neutronics and reactivity depletion analyses examined the effects of various design and material choices on both the cold-clean and the hot-clean excess reactivity, the reactivity shutdown margin, the full power operation life at 100 MW{sub th}, the fissile production and depletion, the

  20. Terahertz optical properties of LBO crystal upon cooling to liquid nitrogen temperature

    Science.gov (United States)

    Nikolaev, N. A.; Andreev, Yu M.; Kononova, N. G.; Mamrashev, A. A.; Antsygin, V. D.; Kokh, K. A.; Kokh, A. E.; Losev, V. F.; Potaturkin, O. I.

    2018-01-01

    The anisotropy of optical properties of nonlinear lithium borate (LBO) crystals in the range of 0.2–2 THz is investigated by time-domain THz spectroscopy at room temperature and at T = 81 K. It is shown that the birefringence dramatically decreases upon cooling, as a result of which phase-matching conditions cannot be implemented. At the same time, the absorption coefficients αx and αy are found to decrease significantly with decreasing temperature, due to which the LBO crystal becomes a promising material for generating THz radiation via optical rectification and fabricating periodic structures and optical elements.

  1. Effect of sintering columns on the heat transfer and flow characteristics of the liquid cooling vapor chambers

    Science.gov (United States)

    Naphon, Paisarn; Wiriyasart, Songkran

    2016-09-01

    The results of the heat and flow characteristics of working fluid inside the vapor chamber with different sintering columns of 20, 81, 225 are presented. The vapor chambers with one inlet port and four outlet ports are tested by using water as coolant. Parametric studies including different heat fluxes, number and size of wick columns, and flow rate of coolants on the cooling performance are considered. A three-dimensional heat and mass transfer model for vapor chamber with wick and without sintering plate and sintering columns are developed. The numerical simulation results show the velocity and pressure distribution of liquid and vapor phases of the working fluid inside the vapor chamber. It is found that the number of wick column have an important influence to the velocity and pressure phenomena of working fluid which results in thermal performance of vapor chamber. Reasonable agreement is obtained from the comparison between the measured data and the predicted results.

  2. On the Importance of the Heat and Mass Transfer Resistances in Internally-Cooled Liquid Desiccant Dehumidifiers and Regenerators

    Energy Technology Data Exchange (ETDEWEB)

    Woods, Jason D [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Kozubal, Eric J [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-02-06

    Liquid desiccant heat and mass exchangers are a promising technology for efficient humidity control in buildings. Many researchers have investigated these exchangers, often using numerical models to predict their performance. However, there is a lack of information in the literature on the magnitude of the heat and mass transfer resistances, both for the dehumidifier (which absorbs moisture from the air) and the regenerator (which heats the liquid desiccant to re-concentrate it). This article focuses on internally-cooled, 3-fluid exchangers in a parallel plate geometry. Water heats or cools a desiccant across a plate, and the desiccant absorbs or releases water into an airstream through a membrane. A sensitivity analysis was used to estimate the importance of each of the heat and mass transfer resistances (air, membrane, desiccant, plate, water), and how it changes with different design geometries. The results show that, for most designs, the latent and sensible heat transfer of the dehumidifier is dominated by the air mass transfer resistance and air heat transfer resistance, respectively. The air mass transfer resistance is also important for the regenerator, but much less so; the change in the desiccant equilibrium humidity ratio due to a change in either temperature or desiccant mass fraction is much higher at the regenerator's higher temperatures. This increases the importance of (1) getting heat from the water to the desiccant/membrane interface, and (2) diffusing salt ions quickly away from the desiccant/membrane interface. The membrane heat transfer and water heat transfer resistances were found to be the least important. These results can help inform decisions about what simplifying assumptions to make in numerical models, and can also help in designing these exchangers by understanding which resistances are most important.

  3. Fabrication and Properties of Micro-Nanoencapsulated Phase Change Materials for Internally-Cooled Liquid Desiccant Dehumidification.

    Science.gov (United States)

    Niu, Xiaofeng; Xu, Qing; Zhang, Yi; Zhang, Yue; Yan, Yufeng; Liu, Tao

    2017-04-29

    Micro-nanoencapsulated phase change materials (M-NEPCMs) are proposed to be useful in liquid desiccant dehumidification by restraining the temperature rise in the moisture-removal process and improving the dehumidification efficiency. In this paper, the n-octadecane M-NEPCMs with desirable thermal properties for internally-cooled dehumidification were fabricated by using compound emulsifiers through the in-situ polymerization method. Melamine-formaldehyde resin was used as the shell material. The effects of the mixing ratio, emulsification methods and amount of the compound emulsifiers on the morphology, size and thermal properties of the M-NEPCMs were investigated experimentally. The optimum weight mixing ratio of the compound emulsifiers is SDS (sodium dodecyl sulfate):Tween80 (polyoxyethylene sorbitan monooleate):Span80 (sorbitan monooleate) = 0.1:0.6:0.3, which achieves the best stability of the n-octadecane emulsion. When the compound emulsifiers are 10 wt. % of the core material, the melting enthalpy of M-NEPCMs reaches its maximum of 145.26 J/g of capsules, with an encapsulation efficiency of 62.88% and a mean diameter of 636 nm. The sub-cooling of the prepared M-NEPCMs is lower than 3 °C, with an acceptable thermal reliability after the thermal cycling test. A pre-emulsification prior to the addition of deionized water in the emulsification is beneficial to the morphology of the capsules, as the phase change enthalpy can be increased by 123.7%.

  4. Establishment of critical hygiene indices for meat cooling processes evaluated by a temperature function integration method.

    Science.gov (United States)

    Lovatt, Simon J; Bell, R Graham; Le Roux, Guillaume J

    2006-09-01

    A temperature function integration technique that involves the calculation of the potential growth of Escherichia coli to obtain a process hygiene index (PHI) is the New Zealand industry standard method for assessing the potential for growth of enteric bacteria during meat cooling processes. The existing criteria to determine the acceptability of a cooling process with PHI values take no account of the differences between meat products and thus limit processing flexibility. A methodology was developed to set criteria for processing acceptability, based on the frequency distribution of the indicator organism E. coli number on meat carcasses immediately after slaughter (in log2 CFU per square centimeter) and a requirement that the E. coli numbers at the end of the cooling process be less than or equal to some maximum acceptable level. This methodology was used, along with accepted guidelines for maximum acceptable levels of E. coli in the meat and measured initial E. coli numbers for the whole New Zealand meat industry, to develop a set of PHI criteria that would be satisfied by a good-practice meat processing operation. A Monte Carlo modeling approach was used to illustrate the implications of these criteria if they had been applied to cooling processes for beef and lamb previously evaluated by the authors. If the proposed criteria were adopted, the maximum allowable PHI for beef cooling could be higher than that for lamb cooling because of the lower initial E. coli numbers found on beef than on lamb carcasses.

  5. Evaluating the Effectiveness of Cooling Vest in a Hot and Humid Environment.

    Science.gov (United States)

    Yi, Wen; Zhao, Yijie; Chan, Albert P C

    2017-05-01

    This study aims to evaluate the effectiveness of a newly designed hybrid cooling vest for construction workers in alleviating heat stress. Two types of cooling vests, namely, a commonly worn Vest A and a newly designed Vest B, were tested in a climatic chamber environment (34.0°C temperature, 60% relative humidity, and 0.4 m s-1 air velocity) using a sweating thermal manikin. Four test scenarios were included: fan off with no phase change materials (PCMs) (Fan-off), fan on with no PCMs (Fan-on), fan off with completely solidified PCMs (PCM + Fan-off), and fan on with completely solidified PCMs (PCM + Fan-on). Test results showed that Vests A and B provided a continuous cooling effect during the 3-h test. The average cooling power for the torso region of Vest B was 67 W, which was higher than that of Vest A (56 W). The addition of PCMs offered a cooling effect of approximately 60 min. Ventilation fans considerably improved the evaporative heat loss compared with the Fan-off condition. The newly designed hybrid cooling vest (Vest B) may be an effective means to reduce heat strain and enhance work performance in a hot and humid environment.

  6. Evaluation of solid–liquid interface profile during continuous casting ...

    Indian Academy of Sciences (India)

    Home; Journals; Bulletin of Materials Science; Volume 24; Issue 4. Evaluation of solid–liquid interface profile during continuous casting by a spline based formalism. S K Das. Metals and Alloys Volume ... Keywords. Continuous casting; solidification; solid–liquid interface; front tracking algorithm; phase change; heat transfer.

  7. A thermomechanical model for the fragmentation of a liquid metal droplet cooled by water

    Science.gov (United States)

    Ivochkin, Yu P.; Monastyrskiy, V. P.

    2017-11-01

    A thermo mechanical aspect of the fragmentation of a liquid metal droplet, solidified as it falls into cold water, is considered in the presented model. The formation of a solid phase in the form of continuous, fluid-tight and relatively rigid casting skin results in a pressure decrease inside the droplet due to the difference between liquid and solid metal density. Because of the high compression modulus of the melt, the pressure in the droplet becomes negative when the thickness of the solid skin achieves several microns. The tensile stress in the melt results in the deformation of the casting skin or the melt’s continuity violation in the form of a shrinkage pore. The rupture of the deformed solid crust results in the penetration of steam jets into the liquid part of the drop. Due to the difference in pressure in the surrounding steam and in the droplet, the casting skin is crushed and the melt is blown out. Both scenarios contribute to the hydrodynamic destruction of the droplet. The suggested thermo mechanical model gives a qualitative explanation for experimental data. In the experimental part of the work, droplets of molten Sn were solidified in water. The solidified pieces of the droplets usually include deformed, thin-walled shells and dispersed particles. On a qualitative level the composition and shape of the solid fragments can be explained within the bounds of the suggested thermo mechanical model.

  8. Photodetachment, electron cooling, and recombination, in a series of neat aliphatic room temperature ionic liquids.

    Science.gov (United States)

    Molins i Domenech, Francesc; Healy, Andrew T; Blank, David A

    2015-08-14

    Transient absorption following photodetachment of a series of neat methyl-alkyl-pyrrolidinium bis(trifluoromethylsulfonyl)amides at 6.20 eV was measured with sub-picosecond time resolution in the visible and near-IR portions of the spectrum. This series spans the onset of structuring in the liquids in the form of polarity alternation. Excitation promotes the electron into a delocalized state with a very large reactive radius. Strong transient absorption is observed in the visible spectrum with a ∼700 fs lifetime, and much weaker, long-lived absorption is observed in the near-IR spectrum. Absorption in the visible is shown to be consistent with the hole, and absorption in the near-IR is assigned to the free solvated electron. Yield of free electrons is estimated at ∼4%, is insensitive to the size of the cation, and is determined in less than 1 ps. Solvation of free electrons depends strongly on the size of the cation and correlates well with the viscosity of the liquid. In addition to radiolytic stability of the aliphatic cations, ultrafast, efficient recombination of separated charge in NTf2 (-) based ionic liquids following photo-excitation near the band-gap may prevent subsequent reactive damage associated with anions.

  9. Deformation behavior of two continuously cooled vanadium microalloyed steels at liquid nitrogen temperature

    Directory of Open Access Journals (Sweden)

    Glišić Dragomir M.

    2013-01-01

    Full Text Available The aim of this work was to establish deformation behaviour of two vanadium microalloyed medium carbon steels with different contents of carbon and titanium by tensile testing at 77 K. Samples were reheated at 1250°C/30 min and continuously cooled at still air. Beside acicular ferrite as dominant morphology in both microstructures, the steel with lower content of carbon and negligible amount of titanium contains considerable fraction of grain boundary ferrite and pearlite. It was found that Ti-free steel exhibits higher strain hardening rate and significantly lower elongation at 77 K than the fully acicular ferrite steel. The difference in tensile behavior at 77 K of the two steels has been associated with the influence of the pearlite, together with higher dislocation density of acicular ferrite. [Projekat Ministarstva nauke Republike Srbije, br. OI174004

  10. Advanced Liquid Cooling for a Traction Drive Inverter Using Jet Impingement and Microfinned Enhanced Surfaces: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Waye, S. K.; Narumanchi, S.; Mihalic, M.; Moreno, G.; Bennion, K.; Jeffers, J.

    2014-08-01

    Jet impingement on plain and micro-finned enhanced surfaces was compared to a traditional channel flow configuration. The jets provide localized cooling to areas heated by the insulated-gate bipolar transistor and diode devices. Enhanced microfinned surfaces increase surface area and thermal performance. Using lighter materials and designing the fluid path to manage pressure losses increases overall performance while reducing weight, volume, and cost. Powering four diodes in the center power module of the inverter and computational fluid dynamics (CFD) modeling was used to characterize the baseline as well as jet-impingement-based heat exchangers. CFD modeling showed the thermal performance improvements should hold for a fully powered inverter. Increased thermal performance was observed for the jet-impingement configurations when tested at full inverter power (40 to 100 kW output power) on a dynamometer. The reliability of the jets and enhanced surfaces over time was also investigated. Experimentally, the junction-to- coolant thermal resistance was reduced by up to 12.5% for jet impingement on enhanced surfaces s compared to the baseline channel flow configuration. Base plate-to-coolant (convective) resistance was reduced by up to 37.0% for the jet-based configuration compared to the baseline, suggesting that while improvements to the cooling side reduce overall resistance, reducing the passive stack resistance may contribute to lowering overall junction-to-coolant resistance. Full inverter power testing showed reduced thermal resistance from the middle of the module baseplate to coolant of up to 16.5%. Between the improvement in thermal performance and pumping power, the coefficient of performance improved by up to 13% for the jet-based configuration.

  11. Energy evaluation of an evaporative cooling system using water driven ejector

    Directory of Open Access Journals (Sweden)

    Cíntia Carla Melgaço de Oliveira

    2014-06-01

    Full Text Available The search for efficient and accessible cooling systems has increased worldwide. This study aims to build and evaluate an evaporative cooling system using a water driven ejector, allowing it to be installed in places with plenty of water. The system was investigated varying the flow rate and temperature of the circulating water, temperature of the replacement water, and coefficient of performance. The best vacuum obtained was 8.5 kPa at nominal operating conditions of 4.1 ± 0.1 m³/h and 5 ± 0.5 ºC for the circulating water reaching the temperature of 9.7 ± 0.5 ºC. The pulse-like disturbance generated by replacing the cooling water at different periods of times did not result in significant affect vacuum destabilization and the temperature rise in the cooling tank. The coefficient of performance of the system at the highest thermal power of 92.27 W was 0.077, which was underestimated due to possible problems related to pump efficiency. The system evaluated under the conditions proposed can be very efficient for cooling fluids at higher temperatures, and it can be complementary to main refrigeration systems.

  12. Status of Physics and Safety Analyses for the Liquid-Salt-Cooled Very High-Temperature Reactor (LS-VHTR)

    Energy Technology Data Exchange (ETDEWEB)

    Ingersoll, DT

    2005-12-15

    A study has been completed to develop a new baseline core design for the liquid-salt-cooled very high-temperature reactor (LS-VHTR) that is better optimized for liquid coolant and that satisfies the top-level operational and safety targets, including strong passive safety performance, acceptable fuel cycle parameters, and favorable core reactivity response to coolant voiding. Three organizations participated in the study: Oak Ridge National Laboratory (ORNL), Idaho National Laboratory (INL), and Argonne National Laboratory (ANL). Although the intent was to generate a new reference LS-VHTR core design, the emphasis was on performing parametric studies of the many variables that constitute a design. The results of the parametric studies not only provide the basis for choosing the optimum balance of design options, they also provide a valuable understanding of the fundamental behavior of the core, which will be the basis of future design trade-off studies. A new 2400-MW(t) baseline design was established that consists of a cylindrical, nonannular core cooled by liquid {sup 7}Li{sub 2}BeF{sub 4} (Flibe) salt. The inlet and outlet coolant temperatures were decreased by 50 C, and the coolant channel diameter was increased to help lower the maximum fuel and vessel temperatures. An 18-month fuel cycle length with 156 GWD/t burnup was achieved with a two-batch shuffling scheme, while maintaining a core power density of 10 MW/m{sup 3} using graphite-coated uranium oxicarbide particle fuel enriched to 15% {sup 235}U and assuming a 25 vol-% packing of the coated particles in the fuel compacts. The revised design appears to have excellent steady-state and transient performance. The previous concern regarding the core's response to coolant voiding has been resolved for the case of Flibe coolant by increasing the coolant channel diameter and the fuel loading. Also, the LSVHTR has a strong decay heat removal performance and appears capable of surviving a loss of forced

  13. Eddy Current Loss Induced in Aluminum Thermal Conduction Strips for ASPCS Coils Indirectly Cooled by Liquid Hydrogen through Thermo-siphon System

    Science.gov (United States)

    Ota, Narumi; Katsura, Masashi; Ando, Kennosuke; Takao, Tomoaki; Shintomi, Takakazu; Makida, Yasuhiro; Hamajima, Takataro; Tsuda, Makoto; Miyagi, Daisuke; Tsujigami, Hiroshi; Fujikawa, Shizuichi; Semba, Toshiaki; Iwaki, Katsuya

    To promote renewable energy sources, we proposed a new system called the Advanced Superconducting Power Conditioning System (ASPCS), which consists of Superconducting Magnetic Energy Storage-system (SMES), Electrolyzer, and Fuel Cell, and is also combined with a liquid hydrogen station for vehicles. The SMES plays a role to compensate the fast fluctuations generated by the renewable energies. In case of the ASPCS with a capacity of 5 MW, we designed the 50 MJ-class SMES composed of 4 solenoid coils. The winding of the solenoid coils is double pancake and a basic coil is 2 m in diameter and 0.5 m in height. Each SMES coil is wound with MgB2 conductor and indirectly cooled at 20 K by liquid hydrogen flowing through a thermo-siphon cooling system. Pure aluminum strips are inserted between the double-pancake coils and the pure aluminum plates gathering the strips lead to liquid hydrogen pipes. This scheme enables the strips and the plates to transfer the heat load in the coils to the cooling pipes and keep the coils at low temperature. On the other hand, we must consider that the strips generate eddy current loss which is strongly affected by a width of the strips. At the same time as the primary study of the SMES coils, we experimented on the thermo-siphon cooling system and investigated the relationship between the heat load and the heat extraction ability of the cooling system. The experiments showed that the cooling system could proficiently function. The estimation of eddy current loss from the particular cooling aluminum strips for the SMES in the ASPCS is reported with the results of the thermo-siphon driving experiment.

  14. Experiments on solar photovoltaic power generation using concentrator and liquid cooling

    Science.gov (United States)

    Beam, B. H.; Hansen, C. F.

    1975-01-01

    Calculations and experimental data are presented leading to the development of a practical, economical solar photovoltaic power supply. The concept involves concentration of sunlight up to about 100 times normal solar intensity in a solar tracking collector and directing this to an array of solar cells. The cells are immersed in water circulated from a thermal reservoir which limits cell temperature rise to about 20 C above ambient during the day and which cools to ambient temperature during the night. Experiments were conducted on solar cells using a Fresnel lens for magnification, a telescope equatorial mount with clock drive, and tap water circulated through the solar cell holder cavity. Test results show that cells operate satisfactorily under these conditions. Power outputs achieved experimentally with cell optimized for 25 suns were linear with concentration to about 15 suns. Cells optimized for 100 suns were not available, but a corresponding linear relation of power output with concentration is anticipated. Test results have been used in a design analysis of the cost of systems utilizing this technique.

  15. Intermediate strength alloys for high temperature service in liquid-salt cooled energy systems

    Science.gov (United States)

    Muralidharan, Govindarajan; Wilson, Dane Francis; Holcomb, David Eugene

    2017-06-20

    An alloy consists essentially of, in terms of weight percent: 6 to 8.5 Cr, 5.5 to 13.5 Mo, 0.4 to 7.5 W, 1 to 2 Ti, 0.7 to 0.85 Mn, 0.05 to 0.3 Al, up to to 0.1 Co, 0.08 to 0.5 C, 1 to 5 Ta, 1 to 4 Nab, 1 to 3 Hf, balance Ni. The alloy is characterized by, at 850.degree. C., a yield strength of at least 36 Ksi, a tensile strength of at least 40 Ksi, a creep rupture life at 12 Ksi of at least 72.1 hours, and a corrosion rate, expressed in weight loss [g/(cm2sec)].times.10.sup.-11 during a 1000 hour immersion in liquid FLiNaK at 850.degree. C., in the range of 8 to 25.

  16. Intermediate strength alloys for high temperature service in liquid-salt cooled energy systems

    Energy Technology Data Exchange (ETDEWEB)

    Muralidharan, Govindarajan; Wilson, Dane Francis; Holcomb, David Eugene

    2017-06-20

    An alloy is composed essentially of, in terms of weight percent: 6 to 8.5 Cr, 5.5 to 13.5 Mo, 0.4 to 7.5 W, 1 to 2 Ti, 0.7 to 0.85 Mn, 0.05 to 0.3 Al, 0.08 to 0.5 C, 0 to 1 Nb, with the balance Ni, the alloy being characterized by, at 850.degree. C., a yield strength of at least 25 Ksi, a tensile strength of at least 30 Ksi, a creep rupture life at 12 Ksi of at least 45 hours, and a corrosion rate, expressed in weight loss [g/(cm.sup.2 sec)]10.sup.-11 during a 1000 hour immersion in liquid FLiNaK at 850.degree. C., in the range of 6 to 39.

  17. Assessment of liquid hydrogen cooled MgB2 conductors for magnetically confined fusion

    Science.gov (United States)

    Glowacki, B. A.; Nuttall, W. J.

    2008-02-01

    Importantly environmental factors are not the only policy-driver for the hydrogen economy. Over the timescale of the development of fusion energy systems, energy security issues are likely to motivate a shift towards both hydrogen production and fusion as an energy source. These technologies combine local control of the system with the collaborative research interests of the major energy users in the global economy. A concept Fusion Island Reactor that might be used to generate H2 (rather than electricity) is presented. Exploitation of produced hydrogen as a coolant and as a fuel is proposed in conjunction with MgB2 conductors for the tokomak magnets windings, and electrotechnical devices for Fusion Island's infrastructure. The benefits of using MgB2 over the Nb-based conductors during construction, operation and decommissioning of the Fusion Island Reactor are presented. The comparison of Nb3Sn strands for ITER fusion magnet with newly developed high field composite MgB2 PIT conductors has shown that at 14 Tesla MgB2 possesses better properties than any of the Nb3Sn conductors produced. In this paper the potential of MgB2 conductors is examined for tokamaks of both the conventional ITER type and a Spherical Tokamak geometry. In each case MgB2 is considered as a conductor for a range of field coil applications and the potential for operation at both liquid helium and liquid hydrogen temperatures is considered. Further research plans concerning the application of MgB2 conductors for Fusion Island are also considered.

  18. Performance evaluation of radiant cooling system application on a university building in Indonesia

    Science.gov (United States)

    Satrio, Pujo; Sholahudin, S.; Nasruddin

    2017-03-01

    The paper describes a study developed to estimate the energy savings potential of a radiant cooling system installed in an institutional building in Indonesia. The simulations were carried out using IESVE to evaluate thermal performance and energy consumption The building model was calibrated using the measured data for the installed radiant system. Then this calibrated model was used to simulate the energy consumption and temperature distribution to determine the proportional energy savings and occupant comfort under different systems. The result was radiant cooling which integrated with a Dedicated Outside Air System (DOAS) could make 41,84% energy savings compared to the installed cooling system. The Computational Fluid Dynamics (CFD) simulation showed that a radiant system integrated with DOAS provides superior human comfort than a radiant system integrated with Variable Air Volume (VAV). Percentage People Dissatisfied was kept below 10% using the proposed system.

  19. Computational Analysis of Supercritical Carbon Dioxide Gas Turbine for Liquid Metal Cooled Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Wi S.; Suh, Kune Y. [Seoul National University, Seoul (Korea, Republic of)

    2008-10-15

    Energy demands at a remote site are increased as the world energy requirement diversifies so that they should generate power on their own site. A Small Modular Reactor (SMR) becomes a viable option for these sites. Generally, the economic feasibility of a high power reactor is greater than that for SMR. As a result the supercritical fluid driven Brayton cycle is being considered for a power conversion system to increase economic competitiveness of SMR. The Brayton cycle efficiency is much higher than that for the Rankine cycle. Moreover, the components of the Brayton cycle are smaller than Rankine cycle's due to high heat capacity when a supercritical fluid is adopted. A lead (Pb) cooled SMR, BORIS, and a supercritical fluid driven Brayton cycle, MOBIS, are being developed at the Seoul National University (SNU). Dostal et al. have compared some advanced power cycles and proposed the use of a supercritical carbon dioxide (SCO{sub 2}) driven Brayton cycle. According to their suggestion SCO{sub 2} is adopted as a working fluid for MOBIS. The turbo machineries are most important components for the Brayton cycle. The turbo machineries of Brayton cycle consists of a turbine to convert kinetic energy of the fluid into mechanical energy of the shaft, and a compressor to recompress and recover the driving force of the working fluid. Therefore, turbine performance is one of the pivotal factors in increasing the cycle efficiency. In MOBIS a supercritical gas turbine is designed in the Gas Advanced Turbine Operation (GATO) and analyzed in the Turbine Integrated Numerical Analysis (TINA). A three-dimensional (3D) numerical analysis is employed for more detailed design to account for the partial flow which the one-dimensional (1D) analysis cannot consider.

  20. Neturonic performance of two European breeder-inside-tube (BIT) blankets for demo: The helium cooled ceramic LiAlO{sub 2} with be multiplier and the water cooled liquid Li17Pb

    Energy Technology Data Exchange (ETDEWEB)

    Petrizzi, L.; Rado, V. [Centro Ricerche Energia Frascati, Rome (Italy)

    1994-12-31

    In the European Community (EC) Test Blanket programme a selection is foreseen, by 1995 of two blanket designs among those under investigation which can be divided in two groups: those using a solid ceramic breeder, all of them helium cooled and with Be neutron multiplier and those using the Ll{sub 17}-Pb liquid metal breeder which could be self or water cooled, depending on the proposal. The design studies have been carried out according to the latest DEMONET specification (2200 MW fusion power, 20000 hours irradiation full power). The present study concerns the most recent neutronic analyses of the two blankets design in which there is ENEA contribution. Both are based on a BIT concept with poloidal running breeding elements which follow the first wall curvature: (1) the helium cooled ceramic BIT with {gamma}-LiAlO{sub 2} breeder material (75% Ll{sup 6} enriched) and Be as neutron multiplier, which has been studied by ENEA since a long time and from 1990, jointly developed with CEA; (2) the water cooled liquid Li{sub 17}Pb (90% Ll{sup 6} enriched) inside cylindrical breeder modules which was originally proposed by JRC Ispra and now it is jointly developed CEA and ENEA.

  1. Fabrication and Properties of Micro-Nanoencapsulated Phase Change Materials for Internally-Cooled Liquid Desiccant Dehumidification

    Directory of Open Access Journals (Sweden)

    Xiaofeng Niu

    2017-04-01

    Full Text Available Micro-nanoencapsulated phase change materials (M-NEPCMs are proposed to be useful in liquid desiccant dehumidification by restraining the temperature rise in the moisture-removal process and improving the dehumidification efficiency. In this paper, the n-octadecane M-NEPCMs with desirable thermal properties for internally-cooled dehumidification were fabricated by using compound emulsifiers through the in-situ polymerization method. Melamine-formaldehyde resin was used as the shell material. The effects of the mixing ratio, emulsification methods and amount of the compound emulsifiers on the morphology, size and thermal properties of the M-NEPCMs were investigated experimentally. The optimum weight mixing ratio of the compound emulsifiers is SDS (sodium dodecyl sulfate:Tween80 (polyoxyethylene sorbitan monooleate:Span80 (sorbitan monooleate = 0.1:0.6:0.3, which achieves the best stability of the n-octadecane emulsion. When the compound emulsifiers are 10 wt. % of the core material, the melting enthalpy of M-NEPCMs reaches its maximum of 145.26 J/g of capsules, with an encapsulation efficiency of 62.88% and a mean diameter of 636 nm. The sub-cooling of the prepared M-NEPCMs is lower than 3 °C, with an acceptable thermal reliability after the thermal cycling test. A pre-emulsification prior to the addition of deionized water in the emulsification is beneficial to the morphology of the capsules, as the phase change enthalpy can be increased by 123.7%.

  2. Evaluating Cool Impervious Surfaces: Application to an Energy-Efficient Residential Roof and to City Pavements

    Science.gov (United States)

    Rosado, Pablo Javier

    heating savings of 4% and electric heating savings of 3%. The slightly positive fractional annual heating energy savings likely resulted from the tile roof's high thermal capacitance, which increased the overnight temperature of the attic air. Thus cool tile roofs should be perceived as a technology that provides energy and environmental benefits during the cooling season as well as the heating season. The second topic investigates the direct and indirect effects of cool pavements on the energy use of California's building stock. First, a simple urban canyon model was developed to calculate the canyon albedo after the user provides the solar position, canyon orientation, and dimensions of the canyon walls, road, and setbacks. Next, a method is presented to correct the values of temperature changes obtained from previous urban climate models to values that would be obtained from canyon geometries that distinguish between road and setbacks (e.g. sidewalk, front yard). The new canyon model is used to scale the temperature changes obtained from a recent urban climate model that simulated the climatological impact of cool pavements on various California cities. The adjusted temperature changes are then combined with building energy simulations to investigate the effect of cool pavements on the cooling, heating, and lighting energy uses of buildings as well as the environmental impact related to these energy uses. Net (direct + indirect) conditioning (cooling + heating) energy savings and environmental savings from cool pavements were smaller in residential buildings than in commercial buildings. Additionally, residential buildings strongly dominate the building stock in all of the evaluated cities. Therefore, even though most cities yielded conditioning energy and environmental savings, they were small due to the minuscule savings from the residential buildings. When increasing the albedo by 0.20 of all public pavements in different California cities, Los Angeles was the city

  3. Performance evaluation of three different types of local evaporative cooling pads in greenhouses in Sudan

    OpenAIRE

    Ahmed, Egbal Mohammed; Abaas, Osama; Ahmed, Mohammed; Ismail, Mohd Rodzi

    2010-01-01

    This study was conducted in Date Palm Technology Company Limited, Shambat, Khartoum State. To evaluate performance of three types of evaporative cooling pads for greenhouses (celdek pads, straw pads and sliced wood pads), as compared to the conditions outside the greenhouses (control), for pads. Performance evaluation includes environmental parameters (temperature and relative humidity at 8 am, 1 pm and 6 pm) and crop parameters (length and stem diameter, leaves number and width, fruit length...

  4. Experimental study of conjugate heat transfer from liquid metal layer cooled by overlying freon

    Energy Technology Data Exchange (ETDEWEB)

    Cho, J.S.; Suh, K.Y.; Chung, C.H. [Seoul National University, Seoul (Korea, Republic of); Park, R.J.; Kim, S.B. [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    2001-07-01

    Steady-state and transient experiments were performed for the heat transfer from the liquid metal pool with overlying Freon (R113) coolant in the process of boiling. The simulant molten pool material is tin (Sn) with the melting temperature of 232 Celsius degrees. The metal pool is heated from the bottom surface and the coolant is injected onto the molten metal pool. Tests were conducted under the condition of the bottom surface heating in the test section and the forced convection of the R113 coolant being injected onto the molten metal pool. The bottom heating condition was varied from 8 kW to 14 kW. The temperature distributions of the metal layer and coolant were obtained in the steady-state experiment. The boiling mechanism of the R113 coolant was changed from the nucleate boiling to film boiling in the transient experiment. The critical heat flux (CHF) phenomenon was observed during the transition from the nucleate boiling to the film boiling. Also, the Nusselt (Nu) number and the Rayleigh (Ra) number in the molten metal pool region were obtained as functions of time. Analysis was done for the relationship between the heat flux and the temperature difference between the metal layer surface and the boiling coolant. In this experiment, the heat transfer is achieved with accompanying solidification in the molten metal pool by the boiling R113 coolant there above. The present test results of the natural convection heat transfer on the molten metal pool are higher than those of the liquid metal natural convection heat transfer without coolant boiling. It can be interpreted that the heat transfer rate is enhanced by the overlying boiling coolant having the high heat removal rate. Analysis of the relationship between the heat flux and the difference between the metal layer surface temperature and the coolant bulk boiling temperature revealed that the CHF occurs when the temperature difference reaches a neighborhood of 50 Celsius degrees. Also, if the temperature

  5. High strength alloys for high temperature service in liquid-salt cooled energy systems

    Science.gov (United States)

    Holcomb, David E.; Muralidharan, Govindarajan; Wilson, Dane F.

    2017-01-10

    An essentially cobalt-free alloy consists essentially of, in terms of weight percent: 6.3 to 7.2 Cr, 0.5 to 2 Al, 0 to 5 Fe, 0.7 to 0.8 Mn, 9 to 12.5 Mo, 0 to 6 Ta, 0.75 to 3.5 Ti, 0.01 to 0.25 Nb, 0.2 to 0.6 W, 0.02 to 0.04 C, 0 to 0.001 B, 0.0001 to 0.002 N, balance Ni. The alloy is characterized by a .gamma.' microstructural component in the range of 3 to 17.6 weight percent of the total composition. The alloy is further characterized by, at 850.degree. C., a yield strength of at least 60 Ksi, a tensile strength of at least 70 Ksi, a creep rupture life at 12 Ksi of at least 700 hours, and a corrosion rate, expressed in weight loss [g/(cm.sup.2sec)]10.sup.-11 during a 1000 hour immersion in liquid FLiNaK at 850.degree. C., in the range of 5.5 to 17.

  6. High strength alloys for high temperature service in liquid-salt cooled energy systems

    Energy Technology Data Exchange (ETDEWEB)

    Holcomb, David E.; Muralidharan, Govindarajan; Wilson, Dane F.

    2017-01-10

    An essentially cobalt-free alloy consists essentially of, in terms of weight percent: 6.3 to 7.2 Cr, 0.5 to 2 Al, 0 to 5 Fe, 0.7 to 0.8 Mn, 9 to 12.5 Mo, 0 to 6 Ta, 0.75 to 3.5 Ti, 0.01 to 0.25 Nb, 0.2 to 0.6 W, 0.02 to 0.04 C, 0 to 0.001 B, 0.0001 to 0.002 N, balance Ni. The alloy is characterized by a .gamma.' microstructural component in the range of 3 to 17.6 weight percent of the total composition. The alloy is further characterized by, at 850.degree. C., a yield strength of at least 60 Ksi, a tensile strength of at least 70 Ksi, a creep rupture life at 12 Ksi of at least 700 hours, and a corrosion rate, expressed in weight loss [g/(cm.sup.2sec)]10.sup.-11 during a 1000 hour immersion in liquid FLiNaK at 850.degree. C., in the range of 5.5 to 17.

  7. Standard Practice for Laboratory Screening of Metallic Containment Materials for Use With Liquids in Solar Heating and Cooling Systems

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1980-01-01

    1.1 This practice covers several laboratory test procedures for evaluating corrosion performance of metallic containment materials under conditions similar to those that may occur in solar heating and cooling systems. All test results relate to the performance of the metallic containment material only as a part of a metal/fluid pair. Performance in these laboratory test procedures, taken by itself, does not necessarily constitute an adequate basis for acceptance or rejection of a particular metal/fluid pair in solar heating and cooling systems, either in general or in a particular design. This practice is not intended to preclude the use of other screening tests, particularly when those tests are designed to more closely simulate field service conditions. 1.2 This practice describes apparatus and procedures for several tests, any one or more of which may be used to evaluate the deterioration of the metallic containment material in a metal/fluid pair. The procedures are designed to permit simulation, heating...

  8. Correlation of cylinder-head temperatures and coolant heat rejections of a multicylinder, liquid-cooled engine of 1710-cubic-inch displacement

    Science.gov (United States)

    Lundin, Bruce T; Povolny, John H; Chelko, Louis J

    1949-01-01

    Data obtained from an extensive investigation of the cooling characteristics of four multicylinder, liquid-cooled engines have been analyzed and a correlation of both the cylinder-head temperatures and the coolant heat rejections with the primary engine and coolant variables was obtained. The method of correlation was previously developed by the NACA from an analysis of the cooling processes involved in a liquid-cooled-engine cylinder and is based on the theory of nonboiling, forced-convection heat transfer. The data correlated included engine power outputs from 275 to 1860 brake horsepower; coolant flows from 50 to 320 gallons per minute; coolants varying in composition from 100 percent water to 97 percent ethylene glycol and 3 percent water; and ranges of engine speed, manifold pressure, carburetor-air temperature, fuel-air ratio, exhaust-gas pressure, ignition timing, and coolant temperature. The effect on engine cooling of scale formation on the coolant passages of the engine and of boiling of the coolant under various operating conditions is also discussed.

  9. Satellite Testbed for Evaluating Cryogenic-Liquid Behavior in Microgravity

    Science.gov (United States)

    Putman, Philip Travis (Inventor)

    2017-01-01

    Provided is a testbed for conducting an experiment on a substance in a cryogenic liquid state in a microgravity environment. The testbed includes a frame with rectangular nominal dimensions, and a source section including a supply of the substance to be evaluated in the cryogenic liquid state. An experiment section includes an experiment vessel in fluid communication with the storage section to receive the substance from the storage section and condense the substance into the cryogenic liquid state. A sensor is adapted to sense a property of the substance in the cryogenic liquid state in the experiment vessel as part of the experiment. A bus section includes a controller configured to control delivery of the substance from the storage section to the experiment vessel, and receive property data indicative of the property sensed by the sensor for subsequent evaluation on Earth.

  10. Evaluation of mercury in the liquid waste processing facilities

    Energy Technology Data Exchange (ETDEWEB)

    Jain, Vijay [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Shah, Hasmukh [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Occhipinti, John E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Wilmarth, William R. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Edwards, Richard E. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2015-08-13

    This report provides a summary of Phase I activities conducted to support an Integrated Evaluation of Mercury in Liquid Waste System (LWS) Processing Facilities. Phase I activities included a review and assessment of the liquid waste inventory and chemical processing behavior of mercury using a system by system review methodology approach. Gaps in understanding mercury behavior as well as action items from the structured reviews are being tracked. 64% of the gaps and actions have been resolved.

  11. Integral and Separate Effects Tests for Thermal Hydraulics Code Validation for Liquid-Salt Cooled Nuclear Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, Per

    2012-10-30

    The objective of the 3-year project was to collect integral effects test (IET) data to validate the RELAP5-3D code and other thermal hydraulics codes for use in predicting the transient thermal hydraulics response of liquid salt cooled reactor systems, including integral transient response for forced and natural circulation operation. The reference system for the project is a modular, 900-MWth Pebble Bed Advanced High Temperature Reactor (PB-AHTR), a specific type of Fluoride salt-cooled High temperature Reactor (FHR). Two experimental facilities were developed for thermal-hydraulic integral effects tests (IETs) and separate effects tests (SETs). The facilities use simulant fluids for the liquid fluoride salts, with very little distortion to the heat transfer and fluid dynamics behavior. The CIET Test Bay facility was designed, built, and operated. IET data for steady state and transient natural circulation was collected. SET data for convective heat transfer in pebble beds and straight channel geometries was collected. The facility continues to be operational and will be used for future experiments, and for component development. The CIET 2 facility is larger in scope, and its construction and operation has a longer timeline than the duration of this grant. The design for the CIET 2 facility has drawn heavily on the experience and data collected on the CIET Test Bay, and it was completed in parallel with operation of the CIET Test Bay. CIET 2 will demonstrate start-up and shut-down transients and control logic, in addition to LOFC and LOHS transients, and buoyant shut down rod operation during transients. Design of the CIET 2 Facility is complete, and engineering drawings have been submitted to an external vendor for outsourced quality controlled construction. CIET 2 construction and operation continue under another NEUP grant. IET data from both CIET facilities is to be used for validation of system codes used for FHR modeling, such as RELAP5-3D. A set of

  12. Evaluation on Long-term Cooling of CANDU after Sump Blockage using MARS-KS

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Seon Oh; Cho, Yong Jin [KINS, Daejeon (Korea, Republic of); Kim, Sung Joong [Hanyang University, Seoul (Korea, Republic of)

    2016-05-15

    There was a real incident that part of the fibrous insulation debris stripped by steam jet was transported to the pool and clogged the intake strainers of the drywell spray system, which revealed a weakness in the defense-in-depth concept which under other circumstances could have led to the ECCS failing to provide coolant to the core. Since the above Barseback-2 incident in 1992, lots of the international activities have been carried out to identify essential parameters and physical phenomena and to promote consensus on the technical issues, important for safety and possible paths for their resolution. In nuclear power plant under operation, if an unplanned reactor trip or a power reduction occurs, operators are required to maintain the reactor in a stable state according to emergency operating procedure (EOP) and to take diagnosis and appropriate mitigation actions if necessary. Subject to the EOP of Wolsong unit 1 (the first Korean PHWR NPP) under LOCA, intact or broken loops are diagnosed using the available plant information such as pressure and temperature of outlet headers. For the intact loop, effective long-term cooling is envisioned through the operation of shutdown cooling system as implemented in the EOP. In this work, the adequacy of long-term cooling during the recirculation phase of LOCA was evaluated under the postulated condition of the reduced flow path of the recirculation sump due to the inflow of substantial amount of debris released by the break flow with high energy. For the intact loop, although the incipience of boiling in the fuel channel was evaluated to occur, the effective long-term cooling can be achieved through the shutdown cooling system as guided in the EOP.

  13. Parameter analysis for feasibility evaluation of shallow groundwater cooling of power plants

    Science.gov (United States)

    Dirix, Katrijn; Harcouët-Menou, Virginie; Van Bael, Johan; Laenen, Ben

    2017-04-01

    This paper presents the first results of a finite difference-based numerical model, aiming to evaluate the potential of a new cooling concept that is based on the use of closed loop groundwater cooling integrated in a binary cycle. The new concept includes the seasonal combination of air cooling and shallow groundwater cooling and is part of the H2020 MATChING project. The proposed cooling system under investigation will be compared with dry type cooler condenser (e.g. air cooled condenser systems) and aims to reduce overall water withdrawal without compromising the energy efficiency of the system. The pilot site for this evaluation is the geothermal Balmatt site in Mol-Dessel, Belgium. When operating at its full potential, this site could produce up to 27 MW of heat. To (partly) cool this heat, water from the permeable Miocene 'Diest formation' could be used in a closed loop, i.e. without consuming water. This aquifer is located at a depth of 35 to 151 m bgl, consists of glauconitic coarse sands and has an average permeability of 10 m/day. The water has a temperature of ca. 12°C. In the design under evaluation, this water will be heated up to a maximum of 22°C after passing through the condenser. During summer months, the water will be injected directly back into the aquifer, while in winter, additional cooling will be realised using an air cooler before injecting the water (at ca. 6 °C). By adding this extra cooling step, the lifetime of the system will increase significantly. To cool the large amount of rejected heat, over 2000 m3/h of water needs to be extracted from the aquifer, requiring the installation of several doublet systems. The feasibility of such an installation depends on several interdependent factors, such as temperature, pressure, well distance, distance between the doublets, permeability and natural flow conditions. Since no exact values of most of these factors are available, a large uncertainty exists for feasibility predictions. To assess

  14. Evaluation of a Passive Heat Exchanger Based Cooling System for Fuel Cell Applications

    Science.gov (United States)

    Colozza, Anthony J.; Burke, Kenneth A.

    2011-01-01

    Fuel cell cooling is conventionally performed with an actively controlled, dedicated coolant loop that exchanges heat with a separate external cooling loop. To simplify this system the concept of directly cooling a fuel cell utilizing a coolant loop with a regenerative heat exchanger to preheat the coolant entering the fuel cell with the coolant exiting the fuel cell was analyzed. The preheating is necessary to minimize the temperature difference across the fuel cell stack. This type of coolant system would minimize the controls needed on the coolant loop and provide a mostly passive means of cooling the fuel cell. The results indicate that an operating temperature of near or greater than 70 C is achievable with a heat exchanger effectiveness of around 90 percent. Of the heat exchanger types evaluated with the same type of fluid on the hot and cold side, a counter flow type heat exchanger would be required which has the possibility of achieving the required effectiveness. The number of heat transfer units required by the heat exchanger would be around 9 or greater. Although the analysis indicates the concept is feasible, the heat exchanger design would need to be developed and optimized for a specific fuel cell operation in order to achieve the high effectiveness value required.

  15. Development of a 1000 kVA oxide superconducting transformer cooled by liquid nitrogen. 4. Ac loss properties.; Ekitai chisso reikyaku 1000 kVA sankabutsu chodendo hen'atsuki no kaihatsu 4. Koryu sonshitsu tokusei

    Energy Technology Data Exchange (ETDEWEB)

    Iwakuma, M.; Fukuda, Y.; Matsumura, K. [Kyushu Univ., Fukuoka (JP)] [and others

    2000-05-29

    In this study group, it developed the liquid nitrogen cooling 22kV/6.9kV-1000kVA single phase superconducting transformer using the Bi2223 superconducting wire rod with the aim of the superconduction of the transformer for urban area underground substation this time. In this paper, ac loss characteristics of the superconductive winding are reported. In developed superconductive winding, the ac loss occupies over half of all thermal load, and it becomes important characteristics, which decide necessary cooling unit capacity and equipment efficiency. In this study, it put principal objective for the establishment of ac loss evaluation technique in the design and ac loss measuring technique of actual equipment. (NEDO)

  16. Evaluation of floor cooling on lactating sows under mild and moderate heat stress

    Science.gov (United States)

    The effectiveness of sow cooling pads during lactation was evaluated under mild and moderate heat stress conditions. The moderate heat stress room was targeted to achieve 32°C from 0800 to 1600 h and 27°C for the rest of the day. The mild heat stress room was targeted to achieve 27°C and 22°C for th...

  17. Design of Complex Systems to Achieve Passive Safety: Natural Circulation Cooling of Liquid Salt Pebble Bed Reactors

    Science.gov (United States)

    Scarlat, Raluca Olga

    This dissertation treats system design, modeling of transient system response, and characterization of individual phenomena and demonstrates a framework for integration of these three activities early in the design process of a complex engineered system. A system analysis framework for prioritization of experiments, modeling, and development of detailed design is proposed. Two fundamental topics in thermal-hydraulics are discussed, which illustrate the integration of modeling and experimentation with nuclear reactor design and safety analysis: thermal-hydraulic modeling of heat generating pebble bed cores, and scaled experiments for natural circulation heat removal with Boussinesq liquids. The case studies used in this dissertation are derived from the design and safety analysis of a pebble bed fluoride salt cooled high temperature nuclear reactor (PB-FHR), currently under development in the United States at the university and national laboratories level. In the context of the phenomena identification and ranking table (PIRT) methodology, new tools and approaches are proposed and demonstrated here, which are specifically relevant to technology in the early stages of development, and to analysis of passive safety features. A system decomposition approach is proposed. Definition of system functional requirements complements identification and compilation of the current knowledge base for the behavior of the system. Two new graphical tools are developed for ranking of phenomena importance: a phenomena ranking map, and a phenomena identification and ranking matrix (PIRM). The functional requirements established through this methodology were used for the design and optimization of the reactor core, and for the transient analysis and design of the passive natural circulation driven decay heat removal system for the PB-FHR. A numerical modeling approach for heat-generating porous media, with multi-dimensional fluid flow is presented. The application of this modeling

  18. RESEARCH OF PROCESSES OF HEAT TRANSFER IN THE COOLING SYSTEM ELEMENTS REA, MADE ON THE BASIS OF MELTING HEAT ACCUMULATORS WITH ADDITIONAL LIQUID HEAT SINK

    Directory of Open Access Journals (Sweden)

    T. A. Ismailov

    2014-01-01

    Full Text Available The paper considers the system of cooling elements REA with intermittent by heat, made on the basis of melting heat accumulators with additional liquid heat sink. The basic computational relations for theoretical studies. Presents the dependence of the length of stable work of the REA element in ensuring its temperature conditions of the investigated system.

  19. Fusible heat sink materials - Evaluation of alternate candidates. [for PLSS cooling systems

    Science.gov (United States)

    Selvaduray, Guna S.; Lomax, W. C.

    1992-01-01

    Fusible heat sinks are a possible source for thermal regulation of space suited astronauts. Materials with greater thermal storage capability than water could enable both an extension of time between recharging and/or a reduction in size and/or mass. An extensive literature search identified 1,215 candidates with a solid-liquid transformation within the temperature range of -13 C to 5 C. Based on data available in the literature, several candidates with a cooling capacity significantly greater than water were identified. Measurements of the transformation temperature and enthalpy of transformation were then undertaken with a differential scanning calorimeter in order to confirm the accuracy of the literature. Laboratory measurements have thus far not been able to corroborate the extremely high values found from the literature. This paper presents the approach for materials selection utilized in this study, the experimental procedure, and the results of the measurements thus far undertaken.

  20. Evaluation of Hole Quality in Hardened Steel with High-Speed Drilling Using Different Cooling Systems

    Directory of Open Access Journals (Sweden)

    Lincoln Cardoso Brandão

    2011-01-01

    Full Text Available This work evaluates the hole quality on AISI H13 hardened steel using high-speed drilling. Specimens were machined with new and worn out drills with 8.6 mm diameter and (TiAlN coating. Two levels of cutting speed and three levels of cooling/lubrication systems (flooded, minimum lubrication quantity, and dry were used. The hole quality is evaluated on surface roughness (Ra parameter, diameter error, circularity, and cylindricity error. A statistical analysis of the results shows that the cooling/lubrication system significantly affects the hole quality for all measured variables. This analysis indicates that dry machining produces the worst results. Higher cutting speeds not only prove beneficial to diameter error and circularity errors, but also show no significant difference on surface roughness and cylindricity errors. The effects of the interaction between the cooling/lubrication systems, tool wear, and cutting speed indicate that only cylindricity error is influenced. Thus, the conclusion is that the best hole quality is produced with a higher cutting speed using flooded or minimum lubrication quantity independent of drill wear.

  1. Analysis of data user's needs for performance evaluation of solar heating and cooling systems

    Science.gov (United States)

    Christensen, D. L.

    1978-01-01

    In a successful data acquisition program, the information needs must be evaluated, the design and cost factors of the program must be determined, and a data management loop must be organized and operated in order to collect, process, and disseminate the needed information in useable formats. This paper describes each of these program elements in detail as an aid for the solar heating and cooling data manager and user to implement effective data acquisition and monitoring systems. Consideration is given to the development of evaluation techniques which will aid in the determination of solar energy systems performances.

  2. Evaluation of the Impact of Slab Foundation Heat Transfer on Heating and Cooling in Florida

    Energy Technology Data Exchange (ETDEWEB)

    Parker, D. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Kono, J. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Vieira, R. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Gu, L. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States)

    2016-09-01

    During the last three decades of energy-efficiency research, there has been limited study of heat transfer to slab-on-grade foundations in cooling-dominated climates. Most experimental research has focused on the impact of slab-on-grade foundations and insulation schemes on heat losses in heating-dominated climates. This is surprising because the floor area in single-family homes is generally equal to wall area, window area, or attic area, all of which have been extensively evaluated for heat-transfer properties. Moreover, slab foundations are the most common foundation type in cooling-dominated climates. Slab-on-grade construction is very popular in southern states, accounting for 77% of new home floors according to 2014 U.S. Census data. There is a widespread perception that tile flooring, as opposed to carpet, provides a cooler home interior in warm climates. Empirical research is needed because building energy simulation software programs running DOE-2 and EnergyPlus engines often rely on simplified models to evaluate the influence of flooring on interior temperature, even though in some cases more detailed models exist. The U.S. Department of Energy Building America Partnership for Improved Residential Construction (BA-PIRC) performed experiments in the Florida Solar Energy Center’s Flexible Residential Test Facility intended to assess for the first time (1) how slab-on-grade construction influences interior cooling in a cooling-dominated climate and (2) how the difference in a carpeted versus uncarpeted building might influence heating and cooling energy use. Two nominally identical side-by-side residential buildings were evaluated during the course of 1 year, from 2014 to 2015: the east building with a pad and carpet floor and the west building with a bare slab floor. A detailed grid shows temperature measurements taken on the slab surface at various locations as well as at depths of 1.0 ft, 2 ft, 5.0 ft, 10.0 ft, and 20.0 ft below the surface. Temperature

  3. Energy and environmental evaluation of combined cooling heating and power system

    Science.gov (United States)

    Bugaj, Andrzej

    2017-11-01

    The paper addresses issues involving problems of implementing combined cooling, heating and power (CCHP) system to industrial facility with well-defined demand profiles of cooling, heating and electricity. The application of CCHP system in this particular industrial facility is being evaluated by comparison with the reference system that consists of three conventional methods of energy supply: (a) electricity from external grid, (b) heat from gas-fired boilers and (c) cooling from vapour compression chillers run by electricity from the grid. The CCHP system scenario is based on the combined heat and power (CHP) plant with gas turbine-compressor arrangement and water/lithium bromide absorption chiller of a single-effect type. Those two scenarios are analysed in terms of annual primary energy usage as well as emissions of CO2. The results of the analysis show an extent of primary energy savings of the CCHP system in comparison with the reference system. Furthermore, the environmental impact of the CCHP usage, in the form of greenhouse gases emission reductions, compares quite favourably with the reference conventional option.

  4. Energy and environmental evaluation of combined cooling heating and power system

    Directory of Open Access Journals (Sweden)

    Bugaj Andrzej

    2017-01-01

    Full Text Available The paper addresses issues involving problems of implementing combined cooling, heating and power (CCHP system to industrial facility with well-defined demand profiles of cooling, heating and electricity. The application of CCHP system in this particular industrial facility is being evaluated by comparison with the reference system that consists of three conventional methods of energy supply: (a electricity from external grid, (b heat from gas-fired boilers and (c cooling from vapour compression chillers run by electricity from the grid. The CCHP system scenario is based on the combined heat and power (CHP plant with gas turbine-compressor arrangement and water/lithium bromide absorption chiller of a single-effect type. Those two scenarios are analysed in terms of annual primary energy usage as well as emissions of CO2. The results of the analysis show an extent of primary energy savings of the CCHP system in comparison with the reference system. Furthermore, the environmental impact of the CCHP usage, in the form of greenhouse gases emission reductions, compares quite favourably with the reference conventional option.

  5. Provisioning cooling elements for chillerless data centers

    Energy Technology Data Exchange (ETDEWEB)

    Chainer, Timothy J.; Parida, Pritish R.

    2018-02-13

    Systems and methods for cooling include one or more computing structure, an inter-structure liquid cooling system that includes valves configured to selectively provide liquid coolant to the one or more computing structures; a heat rejection system that includes one or more heat rejection units configured to cool liquid coolant; and one or more liquid-to-liquid heat exchangers that include valves configured to selectively transfer heat from liquid coolant in the inter-structure liquid cooling system to liquid coolant in the heat rejection system. Each computing structure further includes one or more liquid-cooled servers; and an intra-structure liquid cooling system that has valves configured to selectively provide liquid coolant to the one or more liquid-cooled servers.

  6. Subjective evaluation of different ventilation concepts combined with radiant heating and cooling

    DEFF Research Database (Denmark)

    Krajcik, Michal; Tomasi, Roberta; Simone, Angela

    2012-01-01

    Sixteen subjects evaluated the indoor environment in four experiments with different combinations of ventilation and radiant heating/cooling systems. Two test setups simulated a room in a low energy building with a single occupant during winter. The room was equipped either by a ventilation system...... with displacement ventilation. Vertical air temperature distribution was more uniform for floor heating than for warm air heating, but there was no significant difference in thermal perception between the two mixing ventilation systems. For the summer conditions the subjects voted warmer than predicted by the PMV...

  7. Growing correlation length on cooling below the onset of caging in a simulated glass-forming liquid

    DEFF Research Database (Denmark)

    Lačević, N.; Starr, F. W.; Schrøder, Thomas

    2002-01-01

    We present a calculation of a fourth-order, time-dependent density correlation function that measures higher-order spatiotemporal correlations of the density of a liquid. From molecular dynamics simulations of a glass-forming Lennard-Jones liquid, we find that the characteristic length scale...... of the dynamics of the liquid in the alpha-relaxation regime....

  8. Liquid flat plate collector and pump for solar heating and cooling systems: A collection of quarterly reports

    Science.gov (United States)

    1978-01-01

    Progress in the development, fabrication, and delivery of solar subsystems consisting of a solar operated pump, and solar collectors which can be used in solar heating and cooling, or hot water, for single family, multifamily, or commercial applications is reported.

  9. Comprehensive Evaluation of Biological Growth Control by Chlorine-Based Biocides in Power Plant Cooling Systems Using Tertiary Effluent

    Science.gov (United States)

    Chien, Shih-Hsiang; Dzombak, David A.; Vidic, Radisav D.

    2013-01-01

    Abstract Recent studies have shown that treated municipal wastewater can be a reliable cooling water alternative to fresh water. However, elevated nutrient concentration and microbial population in wastewater lead to aggressive biological proliferation in the cooling system. Three chlorine-based biocides were evaluated for the control of biological growth in cooling systems using tertiary treated wastewater as makeup, based on their biocidal efficiency and cost-effectiveness. Optimal chemical regimens for achieving successful biological growth control were elucidated based on batch-, bench-, and pilot-scale experiments. Biocide usage and biological activity in planktonic and sessile phases were carefully monitored to understand biological growth potential and biocidal efficiency of the three disinfectants in this particular environment. Water parameters, such as temperature, cycles of concentration, and ammonia concentration in recirculating water, critically affected the biocide performance in recirculating cooling systems. Bench-scale recirculating tests were shown to adequately predict the biocide residual required for a pilot-scale cooling system. Optimal residuals needed for proper biological growth control were 1, 2–3, and 0.5–1 mg/L as Cl2 for NaOCl, preformed NH2Cl, and ClO2, respectively. Pilot-scale tests also revealed that Legionella pneumophila was absent from these cooling systems when using the disinfectants evaluated in this study. Cost analysis showed that NaOCl is the most cost-effective for controlling biological growth in power plant recirculating cooling systems using tertiary-treated wastewater as makeup. PMID:23781129

  10. Evaluation of the Passive Cooling Strategies for Pei Min Sport Complex

    Science.gov (United States)

    Yam, K. S.; Yem, W. L.; Lee, V. C. C.

    2017-07-01

    This paper presents a modelling study on the evaluation of the passive cooling strategies for Pei Min sport complex at Miri. The squash centre has experienced excessively high temperature during peak hours that results in complains from the users. We discussed several passive cooling mechanisms and proposed four strategies for the sport centre. Thermal energy simulations were performed on these strategies using OpenStudio to evaluate their impact on the hourly temperature profile within the building. It was found that the peak temperature during the noon was significantly reduced when conductive material was applied at the lower surface of the roof, and the top of the roof was coated with white paint. However, insulating the roof also leads to weaker heat dispersion from the building which lower the rate of temperature drop in the late afternoon. Partitioning the roof was found to have similar effect as insulating roof. Air infiltration is essential for promoting air movement and regulating the temperature within the building. It was found the complex already have sufficient opening for the full effect of air infiltration.

  11. Performance power evaluation of DC fan cooling system for PV panel by using ANSYS CFX

    Science.gov (United States)

    Syafiqah, Z.; Amin, N. A. M.; Irwan, Y. M.; Irwanto, M.; Leow, W. Z.; Amelia, A. R.

    2017-09-01

    A research has been conducted to find the optimum combination for DC fan air cooling system of photovoltaic (PV) panel. During normal operation of PV panel, it is estimated that only 15 % of solar radiation is converted into electrical energy. Meanwhile, the rest of the solar radiation is converted into heat energy which affects the performance of the PV panel. Therefore, the aim of this research is to investigate the performance power evaluation of DC fan cooling system for PV panel by using ANSYS CFX. The effect of airflow configuration of DC fan has been investigated. This is to analyze whether the airflow circulation of DC fan cause a change towards the maximum temperature of PV panel. Besides, the impact of varying number of DC fans attached at the back of PV panel is evaluated. The result of airflow circulation of DC fan has been discussed. Meanwhile, with the increment number of DC fans, the PV panel temperature drops significantly. As a conclusion, the optimum number of DC fans is two with the combination of inlet airflow.

  12. Preliminary evaluation of a pre-industrial air-cooled LiBr-H2O small capacity absorption machine

    OpenAIRE

    Farnós Baulenas, Joan; Castro González, Jesús; Morales Ruíz, Sergio; García Rivera, Eduardo; Oliva Llena, Asensio

    2014-01-01

    The paper describes the thermal design, and evaluates the preliminary operational results of a small capacity pre-industrial LiBr-H2O air-cooled absorption machine in order to validate a numerical model and apply it to simulate a new 7kW LiBr-H2O air-cooled absorption chiller, conceived for low temperature driven, solar cooling or wasted heat. This numerical model is able to simulate the dynamical thermohydraulic behavior of a single-effect absorption machine in transient conditions, being im...

  13. Study of evaluation methods for in-vessel corium retention through external vessel cooling and safety of reactor cavity

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Hoon; Chang, Soon Heung; Choi, Tae Hoon; Kim, Hyun Sop; Yang, Soo Hyung; Kim, Soo Hyung; Kim, Seung Hop; An Hyung Taek; Jeong, Yong Hoon; Huh, Gyun Young [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    1998-03-15

    Cooling methodologies for the molten corium resulted from the severe accident of the nuclear power plant is suggested as one of most important items for the safety of the NPP. In this regard, considerable experimental and analytical works have been devoted. In the 1st phase of this project, present status related to the external reactor vessel cooling for the retention of the corium in the reactor vessel and corium at the reactor cavity have been investigated and preliminary studies have been accomplished for the detail evaluation of the each cooling methodology. The preliminary studies include the analysis and detail investigation of the possible phenomena, investigation of the heat transfer correlations and preliminary evaluation of the external reactor vessel cooling using the developed computer code.

  14. Experimental evaluation of an adaptive Joule–Thomson cooling system including silicon-microfabricated heat exchanger and microvalve components

    OpenAIRE

    Zhu, Weibin; Park, Jong M.; White, Michael J.; Nellis, Gregory F.; Gianchandani, Yogesh B.

    2011-01-01

    This article reports the evaluation of a Joule–Thomson (JT) cooling system that combines two custom micromachined components—a Si/glass-stack recuperative heat exchanger and a piezoelectrically actuated expansion microvalve. With the microvalve controlling the flow rate, this system can modulate cooling to accommodate varying refrigeration loads. The perforated plate Si/glass heat exchanger is fabricated with a stack of alternating silicon plates and Pyrex glass spacers. The microvalve utiliz...

  15. Solid state and sub-cooled liquid vapour pressures of substituted dicarboxylic acids using Knudsen Effusion Mass Spectrometry (KEMS and Differential Scanning Calorimetry

    Directory of Open Access Journals (Sweden)

    A. M. Booth

    2010-05-01

    Full Text Available Solid state vapour pressures of a selection of atmospherically important substituted dicarboxylic acids have been measured using Knudsen Effusion Mass Spectrometry (KEMS over a range of 20 K (298–318 K. Enthalpies of fusion and melting points obtained using Differential Scanning Calorimetry (DSC were used to obtain sub-cooled liquid vapour pressures. They have been compared to estimation methods used on the E-AIM website. These methods are shown to poorly represent – OH groups in combination with COOH groups. Partitioning calculations have been performed to illustrate the impact of the different estimation methods on organic aerosol mass compared to the use of experimental data.

  16. Evaluation of thermal striping for the plugging system in the secondary auxiliary cooling system in JOYO

    Energy Technology Data Exchange (ETDEWEB)

    Isozaki, Kazunori; Ogawa, Tooru; Kubo, Atsuhiko; Aoki, Hiroshi; Ozawa, Kenji [Power Reactor and Nuclear Fuel Development Corp., Oarai, Ibaraki (Japan). Oarai Engineering Center; Sugaya, Kazushi

    1998-05-01

    Scrutiny based on the convenient evaluation to verify whether we have the place where thermal striping in the pipe confluence part was thought to be a primary factor for the heavy accident or not has been done in JOYO. As the result, the big temperature difference ({Delta}Tin) existed at the inner pipe confluence part of the plugging system in the secondary main and auxiliary cooling system. Therefore, detailed evaluation of thermal striping was needed. With the thermocouples of high response installed, the temperature fluctuation in outer surface of the pipe was measured on the secondary auxiliary plugging system for the reason why the temperature difference ({Delta}Tin) was the biggest. And, the temperature fluctuation in inner surface of the pipe and stress occurring in the pipe plate thickness direction was evaluated by means of non-linear structure analysis system FINAS`. The above-mentioned evaluation results were as follows. (1) The maximum temperature fluctuation occurring in the pipe was always located from the center of inner pipe confluence to 10 mm position of the down-stream side. (2) The maximum temperature fluctuation range was about 33degC in outer surface of the pipe. And, controlling frequency of the temperature fluctuation was 0.04 Hz and 0.09 Hz. (3) Time delay was almost never contained in the temperature fluctuation elements between inner and outer surface of the pipe. And, the big temperature distribution did not occur in the pipe plate thickness direction was confirmed that the big temperature distribution did not occur in the pipe plate thickness direction. The temperature fluctuation range in the pipe inner surface was almost the same as that of the pipe outer surface. It was confirmed that the stress occurring there was enough lowered than the design fatigue limit of SUS304 which was the materials in the confluence part of the plugging system inner part in the secondary main and auxiliary cooling system. (J.P.N.)

  17. TASK 2.5.7 FIELD EXPERIMENTS TO EVALUATE COOL-COLORED ROOFING

    Energy Technology Data Exchange (ETDEWEB)

    Miller, William A [ORNL; Cherry, Nigel J [ORNL; Allen, Richard Lowell [ORNL; Childs, Phillip W [ORNL; Atchley, Jerald Allen [ORNL; Ronnen, Levinson [Lawrence Berkeley National Laboratory (LBNL); Akbari, Hashem [Lawrence Berkeley National Laboratory (LBNL); Berhahl, Paul [Lawrence Berkeley National Laboratory (LBNL)

    2010-03-01

    counter battens, providing a nailing surface for the concrete tile. This double batten construction forms an inclined air channel running from the soffit to the ridge. The bottom surface of the channel is formed by the roof decking and is relatively flat and smooth. The top surface is created by the underside of the roofing tiles, and is designed to be an air permeable covering to alleviate the underside air pressure and minimize wind uplift on the tiles. The resulting air flows also have a cooling influence which further complicates prediction of the heat penetrating through the deck because an accurate measure of the airflow is required to predict the heat transfer. Measured temperatures and heat flows at the roof surface, within the attic and at the ceiling of the houses are discussed as well as the power usage to help gauge the benefit of cool-pigmented reflective roof products fitted with and without ventilation above the roof deck. Ventilation occurring above the deck is an inherent feature for tile roof assemblies, and is formed by an air space between the exterior face of the roof sheathing and the underside of the tile. The greater the tile s profile the greater is the effect of the ventilation which herein is termed above-sheathing ventilation (ASV). However, because of the complexity of the thermally induced flow, little credit is allowed by state and federal building codes. ASHRAE (2005) provides empirical data for the effective thermal resistance of plane air spaces. A -in. (0.0191-m) plane air space inclined at 45 with the horizontal has an RUS-0.85 (RSI-0.15) . Our intent is to help further deploy cool color pigments in roofs by conducting field experiments to evaluate the new cool-colored roofing materials in the hot climate of Southern California. The collected data will be used to showcase and market the performance of new cool-roof products and also to help formulate and validate computer codes capable of calculating the heat transfer occurring within

  18. Performance Evaluation of an In-Wheel Motor Cooling System in an Electric Vehicle/Hybrid Electric Vehicle

    Directory of Open Access Journals (Sweden)

    Dong Hyun Lim

    2014-02-01

    Full Text Available High power and miniaturization of motors in an in-wheel drive system, which is installed inside the wheels of a vehicle, are required for directly driving the wheels. In addition, an efficient cooling system is required to ensure high driving performance and durability. This study experimentally evaluated the heat dissipation performance of a 35-kW-class large-capacity in-wheel motor equipped with an internal-circulation-type oil-cooling system that exhibits high cooling performance and can be easily miniaturized to this motor. Temperatures of the coil and stator core of cooling systems with and without a radiator were measured in real time under in-wheel motor driving conditions. It was found that operating the cooling system at a continuous-rating maximum speed without the radiator was difficult. We confirmed that under continuous-rating base speed and continuous-rating maximum speed driving conditions, the cooling system with the radiator showed thermally stable operation. Furthermore, under maximum-rating base speed and maximum-rating maximum speed driving conditions, the cooling system with the radiator provided additional driving times of approximately 22 s and 2 s, respectively.

  19. Performance evaluation of combined ejector LiBr/H2O absorption cooling cycle

    Directory of Open Access Journals (Sweden)

    Hasan Sh. Majdi

    2016-03-01

    Full Text Available The objective of this work is to develop a computer simulation program to evaluate the performance of solar-assited combined ejector absorption (single-effect cooling system using LiBr/H2O as a working fluid and operating under steady-state conditions. The ejector possess no moving parts and is simple and reliable, which makes it attractive for combination with single-stage absorption cycle for further improvement to the system's performance. In this research, improvement to the system is achieved by utilizing the potential kinetic energy of the ejector to enhance refrigeration efficiency. The effects of the entrainment ratio of the ejector, operating temperature, on the thermal loads, and system performance have been investigated. The results showed that the evaporator and condenser loads, post-addition of the ejector, is found to be permanently higher than that in the basic cycle, which indicates a significant enhancement of the proposed cycle and the cooling capacity of the system increasing with the increase in evaporator temperature and entrainment ratio. The COP of the modified cycle is improved by up to 60 % compared with that of the basic cycle at the given condition. This process stabilizes the refrigeration system, enhanced its function, and enabled the system to work under higher condenser temperatures.

  20. Vaporization Would Cool Primary Battery

    Science.gov (United States)

    Bhandari, Pradeep; Miyake, Robert N.

    1991-01-01

    Temperature of discharging high-power-density primary battery maintained below specified level by evaporation of suitable liquid from jacket surrounding battery, according to proposal. Pressure-relief valve regulates pressure and boiling temperature of liquid. Less material needed in cooling by vaporization than in cooling by melting. Technique used to cool batteries in situations in which engineering constraints on volume, mass, and location prevent attachment of cooling fins, heat pipes, or like.

  1. Liquidity in JGB Markets: An Evaluation from Transaction Data

    OpenAIRE

    Tetsuo Kurosaki; Yusuke Kumano; Kota Okabe; Teppei Nagano

    2015-01-01

    There is no single, widely-accepted definition of "market liquidity" even though the expression "market liquidity is high/low" is frequently used, and measuring market liquidity is not easy. Recognizing these challenges, this paper formulates a set of new liquidity indicators using transaction data of the markets related to Japanese government bonds (JGBs), including futures, cash, and special collateral (SC) repo, thereby examining market liquidity from various angles. Traditional liquidity ...

  2. Super-cooled liquid water topped sub-arctic clouds and precipitation - investigation based on combination of ground-based in-situ and remote-sensing observations

    Science.gov (United States)

    Hirsikko, Anne; Brus, David; O'Connor, Ewan J.; Filioglou, Maria; Komppula, Mika; Romakkaniemi, Sami

    2017-04-01

    In the high and mid latitudes super-cooled liquid water layers are frequently observed on top of clouds. These layers are difficult to forecast with numerical weather prediction models, even though, they have strong influence on atmospheric radiative properties, cloud microphysical properties, and subsequently, precipitation. This work investigates properties of super-cooled liquid water layer topped sub-arctic clouds and precipitation observed with ground-based in-situ (cloud probes) and remote-sensing (a cloud radar, Doppler and multi-wavelength lidars) instrumentation during two-month long Pallas Cloud Experiment (PaCE 2015) in autumn 2015. Analysis is based on standard Cloudnet scheme supplemented with new retrieval products of the specific clouds and their properties. Combination of two scales of observation provides new information on properties of clouds and precipitation in the sub-arctic Pallas region. Current status of results will be presented during the conference. The authors acknowledge financial support by the Academy of Finland (Centre of Excellence Programme, grant no 272041; and ICINA project, grant no 285068), the ACTRIS2 - European Union's Horizon 2020 research and innovation programme under grant agreement No 654109, the KONE foundation, and the EU FP7 project BACCHUS (grant no 603445).

  3. A simple and rapid liquid chromatographic assay for evaluation of potentially counterfeit Tamiflu.

    Science.gov (United States)

    Lindegårdh, N; Hien, T T; Farrar, J; Singhasivanon, P; White, N J; Day, N P J

    2006-10-11

    A simple and rapid liquid chromatographic assay for the evaluation of potentially counterfeit oseltamivir (Tamiflu has been developed and assessed. The assay uses approximately 1mg Tamiflu powder when used for authentication and content estimate. The procedure was validated using 50 replicates analysed during five independent series with a total R.S.D. of 11.2%. The assay can also be used to monitor the exact content of oseltamivir in Tamiflu capsules. One Tamiflu capsule was transferred to a 250mL volumetric flask and 150mL water was added. The flask was placed in an ultrasonic bath at 40 degrees C for 20min to dissolve the capsule. The solution was allowed to cool to room temperature before the flask was filled up to the mark (250mL). A small aliquot was centrifuged and then directly injected into the LC-system for quantification. Oseltamivir was analysed by liquid chromatography with UV detection on a Hypersil Gold column (150mmx4.6mm) using a mobile phase containing methanol-phosphate buffer (pH 2.5; 0.1M) (50:50, v/v) at a flow rate of 1.0mL/min. The assay was implemented for the analysis of Tamiflu purchased over the Internet and at local pharmacies in Thailand and Vietnam.

  4. Performance evaluation of three different types of local evaporative cooling pads in greenhouses in Sudan.

    Science.gov (United States)

    Ahmed, Egbal Mohammed; Abaas, Osama; Ahmed, Mohammed; Ismail, Mohd Rodzi

    2011-01-01

    This study was conducted in Date Palm Technology Company Limited, Shambat, Khartoum State. To evaluate performance of three types of evaporative cooling pads for greenhouses (celdek pads, straw pads and sliced wood pads), as compared to the conditions outside the greenhouses (control), for pads. Performance evaluation includes environmental parameters (temperature and relative humidity at 8 am, 1 pm and 6 pm) and crop parameters (length and stem diameter, leaves number and width, fruit length and diameter, fruit weight and dry matter and yield). The results obtained for the temperature at 8 am showed that there was no significant difference (0.05) inside the greenhouses, while a high significant difference between the conditions inside and outside of the greenhouses was found. Significant differences were found at 1 pm and 6 pm between all treatments as compared to the conditions outside the greenhouses, and the results obtained for relative humidity showed high significant differences at 8 am and 1 pm inside the greenhouses and between inside and outside the greenhouse, respectively, while there was no significant difference at 6 pm inside the greenhouses and between inside and outside the greenhouses. On the other hand, the results obtained for crop parameters showed that there were significant differences between all parameters inside the greenhouses and outside the greenhouses; however, the greenhouses with sliced wood pads gave the highest yield and the greenhouses with straw pads gave the least and conditions outside gave the lowest. This study indicated that the sliced wood pads are better than the other evaporative cooling pads.

  5. Infrared camera evaluation of the cooling effect of triamcinolone acetonide aerosol.

    Science.gov (United States)

    Linkner, Rita V; Sohn, Andrew; Goldenberg, Kristin A; Lebwohl, Mark

    2013-11-01

    Triamcinolone acetonide spray is a topical corticosteroid indicated for the relief of inflammatory/pruritic manifestations of corticosteroid-responsive dermatoses. There are clinical reports of an antipruritic, cooling sensation appreciated upon application. This study was designed to quantify the cryotherapeutic cooling effect of triamcinolone acetonide spray. Using an infrared video camera, skin surface temperature was evaluated for change upon application of the triamcinolone acetonide and two comparator ingredient components of triamcinolone acetonide: ethanol alcohol in a non-aerosolized spray and triamcinolone acetonide cream. This was an open-label, single center, comparator study. This study enrolled 20 subjects with a diagnosis of either an acute or chronic steroid-responsive dermatosis. Ten additional controls were also enrolled. Using an infrared video camera, skin surface temperature was evaluated for change upon application of the triamcinolone acetonide and two comparator ingredient components of triamcinolone acetonide:ethanol alcohol in a non-aerosolized spray and triamcinolone acetonide cream. Across every study cohort, the average change in skin surface temperature with triamcinolone acetonide (between 16-18°C; P<0.001 for all comparisons, Figures 1 and 2) was significantly greater than the change demonstrated by both the non-aerosolized spray (between 5-7°C) and the triamcinolone acetonide cream (between 5.0-6.5°C). The transient temperature change of nearly 20°C with triamcinolone acetonide is most likely attributable to the refrigerant properties of the isobutane propellant of this product. Similar to other common cryotherapy methods, triamcinolone acetonide can achieve very low skin surface temperatures, which may result in localized relief of pruritus.

  6. Neutronic performance of two European breeder-inside-tube (BIT) blankets for DEMO: the helium-cooled ceramic LiAlO{sub 2} with Be multiplier and the water-cooled liquid Li{sub 17}Pb

    Energy Technology Data Exchange (ETDEWEB)

    Petrizzi, L. [Associazione EURATOM-ENEA sulla Fusione, Frascati (Italy); Rado, V. [Associazione EURATOM-ENEA sulla Fusione, Frascati (Italy)

    1995-03-01

    In support of ENEA activity in the European Community Test Programme, neutron analysis has been performed on the two latest blanket designs: helium-cooled ceramic breeder-inside-tube (BIT) (with LiAlO{sub 2} and Be multiplier) and water-cooled liquid Li{sub 17}Pb in cylindrical modules (CM). The powerful MCNP Monte Carlo code was used (version 4.2). A detailed and accurate description of the geometrical model has been performed by inserting the main reactor details and avoiding breeder material dilution inside the modules. The tritium breeding ratio (TBR) performance is low for the solid breeder BIT blanket (with 10 ports 1.011) due mainly to low blanket coverage near the exhaust duct, and this solution should be revised. The CM Li{sub 17}Pb blanket reaches a sufficient TBR (1.059, with ports) to rely on tritium self-sufficiency. Shielding properties, with respect to the toroidal field coils, have been estimated in a simplified model by means of the ANISN code, supplied with a nuclear data library consistent with that used by MCNP. The analysis suggests that a careful shield thickness/composition design should be used to ensure the shielding capability of the whole blanket plus shield system. (orig.).

  7. Effects of cryogenic cooling by liquid nitrogen jet on forces, temperature and surface residual stresses in grinding steels

    Science.gov (United States)

    Paul, S.; Chattopadhyay, A. B.

    Grinding is a widely employed finishing process for different materials such as metals, ceramics, glass, carbides, rocks, etc. to achieve good geometrical (form) and dimensional accuracy with acceptable surface finish and surface integrity. However, it is inherently characterized by high specific energy requirements, unlike other conventional machining processes such as turning, milling, etc., which lead to a high grinding zone temperature and poor surface integrity. Many methods have been investigated to control this high grinding zone temperature, but all have their shortfalls, both technological and environmental, in exchange for controlling the grinding zone temperature. This paper briefly discusses the results obtained with regard to grinding forces, specific energy, grinding zone temperature and surface residual stress when using cryogenic cooling and compares them to the results from dry grinding and grinding with soluble oil. Cryogenic cooling seems to have the edge over other coolants in terms of controlling the temperature, residual stresses and grinding forces, and it is also environment friendly.

  8. Enhancement and performance evaluation for heat transfer of air cooling zone for reduction system of sponge titanium

    Science.gov (United States)

    Wang, Wenhao; Wu, Fuzhong; Jin, Huixin

    2017-02-01

    Since the magnesiothermic reduction employed in current sponge titanium is a highly exothermic reaction, the TiCl4 feed rate is carried out slowly to keep a suitable temperature in reduction reactor, which accounts for an extremely low level of productivity and energy efficiency. In order to shorten the production cycle and improve the energy efficiency, an enhancing scheme is proposed to enhance the heat transfer of air cooling zone for reduction system. The air cooling zone and enhancing scheme are firstly introduced. And then, the heat transfer characteristics of cooling zone are obtained by theoretical analysis and experimental date without enhancing scheme. Finally, the enhancement is analyzed and evaluated. The results show that the fitting results of heat transfer coefficients can be used to evaluate the heat transfer enhancement of cooling zone. Heat sources temperatures have a limited decreasing, heat transfer rate increases obviously with the enhanced cooling, and the TiCl4 feed rate can be increased significantly by 9.61 %. And the measured and calculated results are good enough to meet the design requirements.

  9. Evaluation of the NightCool Nocturnal Radiation Cooling Concept: Annual Performance Assessment in Scale Test Buildings Stage Gate 1B

    Energy Technology Data Exchange (ETDEWEB)

    Parker, Danny S. [Florida Solar Energy Center, Cocoa, FL (United States); Sherwin, John R. [Florida Solar Energy Center, Cocoa, FL (United States)

    2008-03-01

    In this report, data is presented on the long-term comparative with all of NightCool system fully operational, with circulating fans when attic conditions are favorable for nocturnal cooling and with conventional air conditioning at other times. Data is included for a full year of the cooling season in Central Florida, which stretches from April to November of 2007.

  10. Performance Evaluation of a Software Engineering Tool for Automated Design of Cooling Systems in Injection Moulding

    NARCIS (Netherlands)

    Jauregui Becker, Juan Manuel; Tosello, Guido; Houten, Fred J.A.M.; Hansen, Hans N.

    2013-01-01

    This paper presents a software tool for automating the design of cooling systems for injection moulding and a validation of its performance. Cooling system designs were automatically generated by the proposed software tool and by applying a best practice tool engineering design approach. The two

  11. Fan and Pad Evaporative Cooling System for Greenhouses: Evaluation of a Numerical and Analytical Model

    NARCIS (Netherlands)

    Sapounas, A.; Nikita-Martzopoulou, Ch.; Bartzanas, T.; Kittas, C.

    2008-01-01

    An experimental greenhouse equipped with fan and pad evaporative cooling is analysed using two different models. The first one consists of a numerical simulation approach applying a commercial CFD code. The main aspects of evaporative cooling systems, in terms of heat and mass transfer and both the

  12. Not cool with cooling

    Science.gov (United States)

    Blain, Barry

    2010-09-01

    I confess that I may have missed the point of Roland Ennos's article "Urban cool" (August pp22-25), which describes methods of cooling cities by mitigating and reversing the effect of solar heating and includes an illustration of "evapotranspiration" in, of all places, Greater Manchester.

  13. Switching Properties of Liquid Nitrogen Cooled IGBTs and 24 kA Demonstration of Current Multiplier by Inductive Storage

    Science.gov (United States)

    Yamada, S.; Nakayama, H.; Aso, Y.

    2014-05-01

    We had been developing a current multiplier by inductive storage (CMIS). The CMIS consists of 24 storage copper coils, which soaked into the liquid nitrogen, demonstrates a 24 kA of output current and the continuous current pulses of 3 pulses per second. Switching performance of the IGBTs and diode were tested in the liquid nitrogen bath. These experimental data were used to design the mega-ampere class CMIS. The system consists of the superconductive magnet section with a temperature of 20 K and the IGBT control switch section with a temperature of 77 K.

  14. Comparison of mineral oil and esters as cooling liquids in high voltage transformer in aspect of environment protection

    Directory of Open Access Journals (Sweden)

    Dombek Grzegorz

    2017-01-01

    Full Text Available The article presents the results of computer simulation of temperature field of transformer filled with mineral oil and alternatives insulating liquids which include synthetic and natural esters. The analysis was based on the results of computer simulation of temperature field of 10 MVA distribution transformer, using the program COMSOL Multiphysics.

  15. 30 CFR 250.248 - What solid and liquid wastes and discharges information and cooling water intake information must...

    Science.gov (United States)

    2010-07-01

    ... Mineral Resources MINERALS MANAGEMENT SERVICE, DEPARTMENT OF THE INTERIOR OFFSHORE OIL AND GAS AND SULPHUR OPERATIONS IN THE OUTER CONTINENTAL SHELF Plans and Information Contents of Development and Production Plans... quantity, and composition of solid and liquid wastes (such as spent drilling fluids, drill cuttings, trash...

  16. Cryogenic generator cooling

    Science.gov (United States)

    Eckels, P. W.; Fagan, T. J.; Parker, J. H., Jr.; Long, L. J.; Shestak, E. J.; Calfo, R. M.; Hannon, W. F.; Brown, D. B.; Barkell, J. W.; Patterson, A.

    The concept for a hydrogen cooled aluminum cryogenic generator was presented by Schlicher and Oberly in 1985. Following their lead, this paper describes the thermal design of a high voltage dc, multimegawatt generator of high power density. The rotor and stator are cooled by saturated liquid and supercritical hydrogen, respectively. The brushless exciter on the same shaft is also cooled by liquid hydrogen. Component development testing is well under way and some of the test results concerning the thermohydraulic performance of the conductors are reported. The aluminum cryogenic generator's characteristics are attractive for hydrogen economy applications.

  17. Model-Based Fault Detection and Isolation of a Liquid-Cooled Frequency Converter on a Wind Turbine

    DEFF Research Database (Denmark)

    Li, Peng; Odgaard, Peter Fogh; Stoustrup, Jakob

    2012-01-01

    With the rapid development of wind energy technologies and growth of installed wind turbine capacity in the world, the reliability of the wind turbine becomes an important issue for wind turbine manufactures, owners, and operators. The reliability of the wind turbine can be improved by implementing...... on the developed dynamical model. The designed fault detection and isolation algorithm is applied on a set of measured experiment data in which different faults are artificially introduced to the scaled cooling system. The experimental results conclude that the different faults are successfully detected...

  18. Evaluation of Liquid-Liquid Extraction Process for Separating Acrylic Acid Produced From Renewable Sugars

    Science.gov (United States)

    Alvarez, M. E. T.; Moraes, E. B.; Machado, A. B.; Maciel Filho, R.; Wolf-Maciel, M. R.

    In this article, the separation and the purification of the acrylic acid produced from renewable sugars were studied using the liquid-liquid extraction process. Nonrandom two-liquids and universal quasi-chemical models and the prediction method univeral quasi-chemical functional activity coefficients were used for generating liquid-liquid equilibrium diagrams for systems made up of acrylic acid, water, and solvents (diisopropyl ether, isopropyl acetate, 2-ethyl hexanol, and methyl isobutyl ketone) and the results were compared with available liquid-liquid equilibrium experimental data. Aspen Plus (Aspen Technology, Inc., version 2004.1) software was used for equilibrium and process calculations. High concentration of acrylic acid was obtained in this article using diisopropyl ether as solvent.

  19. Experimental evaluation of an adaptive Joule-Thomson cooling system including silicon-microfabricated heat exchanger and microvalve components.

    Science.gov (United States)

    Zhu, Weibin; Park, Jong M; White, Michael J; Nellis, Gregory F; Gianchandani, Yogesh B

    2011-03-01

    This article reports the evaluation of a Joule-Thomson (JT) cooling system that combines two custom micromachined components-a Si/glass-stack recuperative heat exchanger and a piezoelectrically actuated expansion microvalve. With the microvalve controlling the flow rate, this system can modulate cooling to accommodate varying refrigeration loads. The perforated plate Si/glass heat exchanger is fabricated with a stack of alternating silicon plates and Pyrex glass spacers. The microvalve utilizes a lead zirconate titanate actuator to push a Si micromachined valve seat against a glass plate, thus modulating the flow passing through the gap between the valve seat and the glass plate. The fabricated heat exchanger has a footprint of 1 × 1 cm(2) and a length of 35 mm. The size of the micromachined piezoelectrically actuated valve is about 1 × 1 × 1 cm(3). In JT cooling tests, the temperature of the system was successfully controlled by adjusting the input voltage of the microvalve. When the valve was fully opened (at an input voltage of -30 V), the system cooled down to a temperature as low as 254.5 K at 430 kPa pressure difference between inlet and outlet at steady state and 234 K at 710 kPa in a transient state. The system provided cooling powers of 75 mW at 255 K and 150 mW at 258 K. Parasitic heat loads at 255 K are estimated at approximately 700 mW.

  20. Technical and economical evaluation of a district cooling system in a commercial area

    Energy Technology Data Exchange (ETDEWEB)

    Holler, S. e-mail: s.holler@mvv.de

    2008-09-15

    As part of a feasibility study a theoretical comparison of technical and economical aspects for a district cooling system in a commercial area in Mannheim, Germany has been made. On the basis of a newly developed cadastre of cooling a suitable site was selected for further examination. Different technical concepts including compression and absorption chillers as well as a cool thermal storage have been analysed. Under the specific premises of the chosen commercial district a cold water system with centralised centrifugal compressors and chilled water storage is the most economic alternative

  1. Use and Evaluation of a Cooling Aid in Laser-Assisted Dental Surgery: An Innovative Study.

    Science.gov (United States)

    Bernardi, Sara; Mummolo, Stefano; Zeka, Keti; Pajewski, Leonardo; Continenza, Maria Adelaide; Marzo, Giuseppe

    2016-06-01

    The aim of this study was to evaluate the beneficial effect of NeoHeal during laser-assisted oral surgery. Laser-assisted surgery is a less invasive technique than conventional surgery using a blade; however, the heat produced by the laser can damage tissue proximal to the treated area. We hypothesized the hydrogel NeoHeal could be applied during oral surgery and have similar benefits as those already described for dermatological surgery. In our randomized controlled trial, we first selected 30 patients who were to undergo laser surgical intervention using a diode laser. Both at the end of intervention and at follow-up, each patient filled out a questionnaire comprising two questions. The answers to the questions were statistically analyzed with regard to frequency of each response, and validated by the Wilcoxon test with a p value <0.05 being considered significant. The use of NeoHeal significantly reduced the pain experienced by patients both during the intervention and at the 7-day follow-up. NeoHeal clearly reduces surgery-related pain experienced by patients. The results show positive feedback from the patients, demonstrating how the hydrogel pads are necessary, useful, and effective as a cooling aid in laser-assisted dental surgery.

  2. PERFORMANCE EVALUATION OF LIQUID-COOLED PHOTOVOLTAIC SYSTEM USING NUMERICAL METHOD

    Directory of Open Access Journals (Sweden)

    Yasaman Khanjari

    2016-12-01

    Full Text Available The purpose of present study is establishing a simulation model to consider the performance of a water photovoltaic thermal system (PV/T via the computational fluid dynamics method (CFD. The proposed model includes a water riser tube and an absorber plate to consider the conduction and convection heat transfer mechanisms. The simulation process was carried out in the ANSYS FLUENT software. The effects of two different parameters on the efficiency and performance of the system were investigated numerically. The performance of the PV/T system versus the changes in the absorbed radiation on the plate and the fluid inlet temperature were analyzed. The temperature distribution of different sections of the system was obtained. For validation of the presented method, a comparison study was carried out with the experimental results in the literature; satisfactory convergences were found between the measured data and the experimental results.

  3. Comparative evaluation of pebble-bed and prismatic fueled high-temperature gas-cooled reactors

    Energy Technology Data Exchange (ETDEWEB)

    Kasten, P.R.; Bartine, D.E.

    1981-01-01

    A comparative evaluation has been performed of the HTGR and the Federal Republic of Germany's Pebble Bed Reactor (PBR) for potential commercial applications in the US. The evaluation considered two reactor sizes (1000 and 3000 MW(t)) and three process applications (steam cycle, direct cycle, and process heat, with outlet coolant temperatures of 750, 850, and 950/sup 0/C, respectively). The primary criterion for the comparison was the levelized (15-year) cost of producing electricity or process heat. Emphasis was placed on the cost impact of differences between the prismatic-type HTGR core, which requires periodic refuelings during reactor shutdowns, and the pebble bed PBR core, which is refueled continuously during reactor operations. Detailed studies of key technical issues using reference HTGR and PBR designs revealed that two cost components contributing to the levelized power costs are higher for the PBR: capital costs and operation and maintenance costs. A third cost component, associated with nonavailability penalties, tended to be higher for the PBR except for the process heat application, for which there is a large uncertainty in the HTGR nonavailability penalty at the 950/sup 0/C outlet coolant temperature. A fourth cost component, fuel cycle costs, is lower for the PBR, but not sufficiently lower to offset the capital cost component. Thus the HTGR appears to be slightly superior to the PBR in economic performance. Because of the advanced development of the HTGR concept, large HTGRs could also be commercialized in the US with lower R and D costs and shorter lead times than could large PBRs. It is recommended that the US gas-cooled thermal reactor program continue giving primary support to the HTGR, while also maintaining its cooperative PBR program with FRG.

  4. Testing and performance analysis of a hollow fiber-based core for evaporative cooling and liquid desiccant dehumidification

    DEFF Research Database (Denmark)

    Jradi, Muhyiddine; Riffat, Saffa

    2016-01-01

    In this study, an innovative heat and mass transfer core is proposed to provide thermal comfort and humidity control using a hollow fiber contactor with multiple bundles of micro-porous hollow fibers. The hollow fiberbased core utilizes 12 bundles aligned vertically, each with 1,000 packed polypr...... of 47%. Being cheap and simple to design with their attractive heat and mass transfer characteristics and the corresponding large surface area-to-volume ratio, hollow fiber membrane contactors provide a promising alternative for cooling and dehumidification applications.......In this study, an innovative heat and mass transfer core is proposed to provide thermal comfort and humidity control using a hollow fiber contactor with multiple bundles of micro-porous hollow fibers. The hollow fiberbased core utilizes 12 bundles aligned vertically, each with 1,000 packed...

  5. Liquid hot NAGMA cooled to 0.4 K: benchmark thermochemistry of a gas-phase peptide.

    Science.gov (United States)

    Leavitt, Christopher M; Moore, Kevin B; Raston, Paul L; Agarwal, Jay; Moody, Grant H; Shirley, Caitlyne C; Schaefer, Henry F; Douberly, Gary E

    2014-10-16

    Vibrational spectroscopy and helium nanodroplet isolation are used to determine the gas-phase thermochemistry for isomerization between conformations of the model dipeptide, N-acetylglycine methylamide (NAGMA). A two-stage oven source is implemented to produce a gas-phase equilibrium distribution of NAGMA conformers, which is preserved when individual molecules are captured and cooled to 0.4 K by He nanodroplets. With polarization spectroscopy, the IR spectrum in the NH stretch region is assigned to a mixture of two conformers having intramolecular hydrogen bonds composed of either five- or seven-membered rings, C5 and C7, respectively. The C5 to C7 interconversion enthalpy and entropy, obtained from a van't Hoff analysis, are -4.52 ± 0.12 kJ/mol and -12.4 ± 0.2 J/(mol · K), respectively. The experimental thermochemistry is compared to high-level electronic structure theory computations.

  6. Optimization of multi response in end milling process of ASSAB XW-42 tool steel with liquid nitrogen cooling using Taguchi-grey relational analysis

    Science.gov (United States)

    Norcahyo, Rachmadi; Soepangkat, Bobby O. P.

    2017-06-01

    A research was conducted for the optimization of the end milling process of ASSAB XW-42 tool steel with multiple performance characteristics based on the orthogonal array with Taguchi-grey relational analysis method. Liquid nitrogen was applied as a coolant. The experimental studies were conducted under varying the liquid nitrogen cooling flow rates (FL), and the end milling process variables, i.e., cutting speed (Vc), feeding speed (Vf), and axial depth of cut (Aa). The optimized multiple performance characteristics were surface roughness (SR), flank wear (VB), and material removal rate (MRR). An orthogonal array, signal-to-noise (S/N) ratio, grey relational analysis, grey relational grade, and analysis of variance were employed to study the multiple performance characteristics. Experimental results showed that flow rate gave the highest contribution for reducing the total variation of the multiple responses, followed by cutting speed, feeding speed, and axial depth of cut. The minimum surface roughness, flank wear, and maximum material removal rate could be obtained by using the values of flow rate, cutting speed, feeding speed, and axial depth of cut of 0.5 l/minute, 109.9 m/minute, 440 mm/minute, and 0.9 mm, respectively.

  7. Characterizing Flow-Induced Vibrations of Fuel Assemblies for Future Liquid Metal Cooled Nuclear Reactors Using Quasi-Distributed Fibre-Optic Sensors

    Directory of Open Access Journals (Sweden)

    Ben De Pauw

    2017-08-01

    Full Text Available Excessive vibration of nuclear reactor components, such as the heat exchanger or the fuel assembly should be avoided as these can compromise the lifetime of these components and potentially lead to safety hazards. This issue is particularly relevant to new reactor designs that use liquid metal coolants. However, identifying adequate sensors or techniques that can be successfully applied to record the vibrations of the components in a flow of liquid metal at elevated temperatures is very challenging. In this paper, we demonstrate the precise measurements of the vibrations of a very representative mock-up of a fuel assembly in a lead-bismuth eutectic cooled installation using quasi-distributed fibre Bragg grating (FBG based sensors. The unique properties of these sensors, in combination with a dedicated integration and mounting approach, allows for accounting of the severe geometrical constraints and allows characterizing the vibration of the fuel assembly elements under nominal operation conditions. To that aim, we instrumented a single fuel pin within the fuel assembly with 84 FBGs, and conducted spectral measurements with an acquisition rate of up to 5000 measurements per second, enabling the monitoring of local strains of a few με. These measurements provide the information required to assess vibration-related safety hazards.

  8. Test of a cryogenic set-up for a 10 meter long liquid nitrogen cooled superconducting power cable

    DEFF Research Database (Denmark)

    Træholt, Chresten; Rasmussen, Carsten; Kühle (fratrådt), Anders Van Der Aa

    2000-01-01

    of a superconducting cable includes the thermal insulation of the cable, the current- and coolant feed-throughs and possibly dynamic vacuum control. Since feed-throughs represent major sources of heat in-leak to the cryogenic system it is important to optimise the design and the number of these in a superconducting...... cable. We report on our experimental set-up for testing a 10 meter long high temperature superconducting cable with a critical current of 3.2 kA at 77K. The set-up consists of a custom designed cable end termination, current lead, coolant feed-through, liquid nitrogen closed loop circulation system...

  9. Gas turbine cooling system

    Science.gov (United States)

    Bancalari, Eduardo E.

    2001-01-01

    A gas turbine engine (10) having a closed-loop cooling circuit (39) for transferring heat from the hot turbine section (16) to the compressed air (24) produced by the compressor section (12). The closed-loop cooling system (39) includes a heat exchanger (40) disposed in the flow path of the compressed air (24) between the outlet of the compressor section (12) and the inlet of the combustor (14). A cooling fluid (50) may be driven by a pump (52) located outside of the engine casing (53) or a pump (54) mounted on the rotor shaft (17). The cooling circuit (39) may include an orifice (60) for causing the cooling fluid (50) to change from a liquid state to a gaseous state, thereby increasing the heat transfer capacity of the cooling circuit (39).

  10. Evaluating the Physiological and Perceptual Responses of Wearing a Newly Designed Cooling Vest for Construction Workers.

    Science.gov (United States)

    Zhao, Yijie; Yi, Wen; Chan, Albert P C; Wong, Francis K W; Yam, Michael C H

    2017-08-01

    Construction workers are subjected to heat stress because of the hot environment, physically demanding tasks, and/or personal protective equipment. A tailor-made cooling vest that protects construction workers from heat-related injuries was developed. The purpose of the study is to examine a newly designed cooling vest's effectiveness in alleviating physiological and perceptual strain in a hot and humid environment. Twelve male participants performed two trials, i.e., cooling vest (VEST) and control (CON) in a climatic chamber controlled at 37°C temperature, 60% relative humidity, 0.3 m/s air velocity, and 450 W/m2 solar radiation to simulate the summer working environment of construction sites. Two bouts of treadmill exercise intermitted with 30-minute passive recovery were designed to simulate the practical work-rest schedule of the construction industry. The cooling vest was used during the passive recovery period in the VEST condition, and the results were compared with that of no cooling vest in the CON condition. The results revealed that the newly designed cooling vest can significantly alleviate heat strain and improve thermal comfort, based on the decrease in body temperature, heart rate, and subjective perceptions (including perceived exertion, thermal, wetness, and comfort sensation) of the participants. It can also prolong work duration in the subsequent exercise. The cooling countermeasures proposed in this study will be able to provide an effective solution in situations that involve repeated bouts of outdoor construction work. © The Author 2017. Published by Oxford University Press on behalf of the British Occupational Hygiene Society.

  11. High Performance Torso Cooling Garment

    Science.gov (United States)

    Conger, Bruce; Makinen, Janice

    2016-01-01

    The concept proposed in this paper is to improve thermal efficiencies of the liquid cooling and ventilation garment (LCVG) in the torso area, which could facilitate removal of LCVG tubing from the arms and legs, thereby increasing suited crew member mobility. EVA space suit mobility in micro-gravity is challenging, and it becomes even more challenging in the gravity of Mars. By using shaped water tubes that greatly increase the contact area with the skin in the torso region of the body, the heat transfer efficiency can be increased. This increase in efficiency could provide the required liquid cooling via torso tubing only; no arm or leg LCVG tubing would be required. Benefits of this approach include increased crewmember mobility, enhanced evaporation cooling, increased comfort during Mars EVA tasks, and easing of the overly dry condition in the helmet associated with the Advanced Extravehicular Mobility Unit (EMU) ventilation loop currently under development. This report describes analysis and test activities performed to evaluate the potential improvements to the thermal performance of the LCVG. Analyses evaluated potential tube shapes for improving the thermal performance of the LCVG. The analysis results fed into the selection of flat flow strips to improve thermal contact with the skin of the suited test subject. Testing of small segments was performed to compare thermal performance of the tubing approach of the current LCVG to the flat flow strips proposed as the new concept. Results of the testing is presented along with recommendations for future development of this new concept.

  12. Temperature Field Accurate Modeling and Cooling Performance Evaluation of Direct-Drive Outer-Rotor Air-Cooling In-Wheel Motor

    Directory of Open Access Journals (Sweden)

    Feng Chai

    2016-10-01

    Full Text Available High power density outer-rotor motors commonly use water or oil cooling. A reasonable thermal design for outer-rotor air-cooling motors can effectively enhance the power density without the fluid circulating device. Research on the heat dissipation mechanism of an outer-rotor air-cooling motor can provide guidelines for the selection of the suitable cooling mode and the design of the cooling structure. This study investigates the temperature field of the motor through computational fluid dynamics (CFD and presents a method to overcome the difficulties in building an accurate temperature field model. The proposed method mainly includes two aspects: a new method for calculating the equivalent thermal conductivity (ETC of the air-gap in the laminar state and an equivalent treatment to the thermal circuit that comprises a hub, shaft, and bearings. Using an outer-rotor air-cooling in-wheel motor as an example, the temperature field of this motor is calculated numerically using the proposed method; the results are experimentally verified. The heat transfer rate (HTR of each cooling path is obtained using the numerical results and analytic formulas. The influences of the structural parameters on temperature increases and the HTR of each cooling path are analyzed. Thereafter, the overload capability of the motor is analyzed in various overload conditions.

  13. The evaluation of pressure effects on the ex-vessel cooling for KNGR with MELCOR

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jong Hwa; Park, Soo Yong; Kim, Dong Ha

    2001-03-01

    In this report, the effect of external vessel cooling on debris coolability and vessel integrity for the KNGR were examined from the two typical pressure range of high(170 bar) and low(5 bar)case using the lower plenum model in MELCOR1.8.4. As the conditions of these calculations, 80 ton of debris was relocated simultaneously into the lower vessel head and the debris relocation temperature from the core region was 2700 K. The decay heat has been assumed to be that of one hour after reactor shutdown. The creep failure of the vessel wall was simulated with 1-D model, which can consider the rapid temperature gradient over the wall thickness during the ex-vessel cooling. From the calculation results, both the coolant temperature and the total amount of coolant mass injected into the cavity are known to be the important factors in determining the time period to keep the external vessel cool. Therefore, a long-term strategy to keep the coolant temperature subcooled throughout the transient is suggested to sustain or prolong the effect of external vessel cooling. Also, it is expected that to keep the primary side at low pressure and to perform the ex-vessel flooding be the essential conditions to sustain the vessel integrity. From MELCOR, the penetration failure always occurs after relocation regardless of the RCS pressure or availability of the external vessel cooling. Therefore, It is expected that the improvement of the model for the penetration tube failure will be necessary.

  14. An Evaluation of a Passively Cooled Cylindrical Spectrometer Array in Lunar Orbit

    Science.gov (United States)

    Waggoner, Jason

    2014-01-01

    This thesis will evaluate a passively cooled cylindrical spectrometer array in lunar orbit characterizing the thermal response in order to provide context for decision-making to scientists and engineers. To provide perspective on thermal issues and controls of space science instruments, a background search of historical lunar missions is provided. Next, a trial science mission is designed and analyzed which brings together the elements of the background search, lunar orbit environment and passive cooling. Finally, the trial science mission analysis results are provided along with the conclusions drawn. Scintillators are materials that when struck by particle radiation, absorb the particle energy which is then reemitted as light in or near the visible range. Nuclear astrophysics utilizes scintillating materials for observation of high-energy photons which are generated by sources such as solar flares, supernovae and neutron stars. SPMs are paired with inorganic scintillators to detect the light emitted which is converted into electronic signals. The signals are captured and analyzed in order to map the number and location of the high-energy sources. The SPM is utilized as it has single photon sensitivity, low voltage requirements and a fast response. SPMs are also compact, relatively inexpensive and allow the usage of lower-cost scintillating materials within the spectrometer. These characteristics permit large-area arrays while lowering cost and power requirements. The ability of a spectrometer to record and identify the interaction of high-energy photons for scientific return is not a trivial matter. Background noise is generated when particles that have not originated from the desired distant source impact the spectrometer. Additionally, thermally induced electrical signals are randomly generated within the SPM even in the absence of light which is referred to as dark current. Overcoming these obstacles requires greater light emittance and energy resolution with

  15. Performance Evaluation of a Software Engineering Tool for Automated Design of Cooling Systems in Injection Moulding

    DEFF Research Database (Denmark)

    Jauregui-Becker, Juan M.; Tosello, Guido; van Houten, Fred J.A.M.

    2013-01-01

    This paper presents a software tool for automating the design of cooling systems for injection moulding and a validation of its performance. Cooling system designs were automatically generated by the proposed software tool and by applying a best practice tool engineering design approach. The two...... different design methods (i.e. automatic and manual) were applied to the mould design of two thin-walled products, namely a rectangular flat box and a cylindrical container with a flat base. Injection moulding process simulations based on the finite element method were performed to assess the quality...

  16. Application of ATHLET/DYN3D coupled codes system for fast liquid metal cooled reactor steady state simulation

    Science.gov (United States)

    Ivanov, V.; Samokhin, A.; Danicheva, I.; Khrennikov, N.; Bouscuet, J.; Velkov, K.; Pasichnyk, I.

    2017-01-01

    In this paper the approaches used for developing of the BN-800 reactor test model and for validation of coupled neutron-physic and thermohydraulic calculations are described. Coupled codes ATHLET 3.0 (code for thermohydraulic calculations of reactor transients) and DYN3D (3-dimensional code of neutron kinetics) are used for calculations. The main calculation results of reactor steady state condition are provided. 3-D model used for neutron calculations was developed for start reactor BN-800 load. The homogeneous approach is used for description of reactor assemblies. Along with main simplifications, the main reactor BN-800 core zones are described (LEZ, MEZ, HEZ, MOX, blankets). The 3D neutron physics calculations were provided with 28-group library, which is based on estimated nuclear data ENDF/B-7.0. Neutron SCALE code was used for preparation of group constants. Nodalization hydraulic model has boundary conditions by coolant mass-flow rate for core inlet part, by pressure and enthalpy for core outlet part, which can be chosen depending on reactor state. Core inlet and outlet temperatures were chosen according to reactor nominal state. The coolant mass flow rate profiling through the core is based on reactor power distribution. The test thermohydraulic calculations made with using of developed model showed acceptable results in coolant mass flow rate distribution through the reactor core and in axial temperature and pressure distribution. The developed model will be upgraded in future for different transient analysis in metal-cooled fast reactors of BN type including reactivity transients (control rods withdrawal, stop of the main circulation pump, etc.).

  17. Experimental evaluation of an adaptive Joule–Thomson cooling system including silicon-microfabricated heat exchanger and microvalve components

    Science.gov (United States)

    Zhu, Weibin; Park, Jong M.; White, Michael J.; Nellis, Gregory F.; Gianchandani, Yogesh B.

    2011-01-01

    This article reports the evaluation of a Joule–Thomson (JT) cooling system that combines two custom micromachined components—a Si/glass-stack recuperative heat exchanger and a piezoelectrically actuated expansion microvalve. With the microvalve controlling the flow rate, this system can modulate cooling to accommodate varying refrigeration loads. The perforated plate Si/glass heat exchanger is fabricated with a stack of alternating silicon plates and Pyrex glass spacers. The microvalve utilizes a lead zirconate titanate actuator to push a Si micromachined valve seat against a glass plate, thus modulating the flow passing through the gap between the valve seat and the glass plate. The fabricated heat exchanger has a footprint of 1×1 cm2 and a length of 35 mm. The size of the micromachined piezoelectrically actuated valve is about 1×1×1 cm3. In JT cooling tests, the temperature of the system was successfully controlled by adjusting the input voltage of the microvalve. When the valve was fully opened (at an input voltage of −30 V), the system cooled down to a temperature as low as 254.5 K at 430 kPa pressure difference between inlet and outlet at steady state and 234 K at 710 kPa in a transient state. The system provided cooling powers of 75 mW at 255 K and 150 mW at 258 K. Parasitic heat loads at 255 K are estimated at approximately 700 mW. PMID:21552354

  18. Efficiency Evaluation on a CoolMos Switching and IGBT Conducting Multilevel Inverter

    DEFF Research Database (Denmark)

    Anthon, Alexander; Zhang, Zhe; Andersen, Michael A. E.

    2015-01-01

    This paper deals with a three-level inverter topology in the 3 kW range as an alternative to commonly used three-level topologies. The topology is attractive for having low switching losses due to the utilization of CoolMos switching devices while keeping conduction losses low due to the utilizat...

  19. Evaluation of Cooling Rate Effects on the Mechanical Properties of Die Cast Magnesium Alloy AM60

    Science.gov (United States)

    Sharifi, P.; Fan, Y.; Anaraki, H. B.; Banerjee, A.; Sadayappan, K.; Wood, J. T.

    2016-10-01

    With the increased application of magnesium high-pressure die castings (HPDC), it is necessary to better understand process-structure-mechanical properties. In the case of HPDC, ductility and yield strength strongly depend on porosity, grain size, and the skin thickness. In this contribution, a new method is developed which employs knowledge of local cooling rates to predict the grain size and the skin thickness of HPDC magnesium components. The centreline cooling curve, together with the die temperature, and the thermodynamic properties of the alloy are then used as inputs to compute the solution to the Stefan problem of a moving phase boundary, thereby providing the through-thickness cooling curves at each chosen location of the casting. The local cooling rate is used to calculate the resulting grain size and skin thickness via established relationships. The prediction of skin thickness and average grain size of skin region determined from this method compares quite well with the experimental results. Due to the presence of externally solidified grains, this method underestimates the grain size value in the core region, as compared to the experiment. Finally, we predict the locally varying yield strength using a modified Hall-Petch equation.

  20. Numerical evaluation of spherical geometry approximation for heating and cooling of irregular shaped food products.

    Science.gov (United States)

    Uyar, Rahmi; Erdogdu, Ferruh

    2012-07-01

    Irregular shapes of food products add difficulties in modeling of food processes, and using actual geometries might be in expense of computing time without offering any advantages in heating and cooling processes. In this study, a three-dimensional scanner was used to obtain geometrical description of strawberry, pear, and potato, and cooling-heating simulations were carried out in a computational heat transfer program. Then, spherical assumption was applied to compare center and volume average temperature changes using volume to surface area ratios of these samples to define their characteristic length. In addition, spherical assumption for a finite cylinder and a cube was also applied to demonstrate the effect of sphericity. Geometries with sphericity values above 0.9 were determined to hold the spherical assumption. Irregular shapes of food products add difficulties in modeling of heating and cooling processes of food products. In addition, using actual geometries are in expense of computational time without offering any advantages. Hence, spherical approximation for irregular geometries was demonstrated under sphericity values of 0.9. This approach might help in developing better heating and cooling processes. © 2012 Institute of Food Technologists®

  1. Evaluating the performance of a new model for predicting the growth of Clostridium perfringens in cooked, uncured meat and poultry products under isothermal, heating, and dynamically cooling conditions

    Science.gov (United States)

    Clostridium perfringens Type A is a significant public health threat and may germinate, outgrow, and multiply during cooling of cooked meats. This study evaluates a new C. perfringens growth model in IPMP Dynamic Prediction using the same criteria and cooling data in Mohr and others (2015), but inc...

  2. Analysis of liquid-metal-jet impingement cooling in a corner region and for a row of jets

    Science.gov (United States)

    Siegel, R.

    1975-01-01

    A conformal mapping method was used to analyze liquid-metal-jet impingement heat transfer. The jet flow region and energy equation are transformed to correspond to uniform flow in a parallel plate channel with nonuniform heat addition along a portion of one wall. The exact solution for the wall-temperature distribution was obtained in the transformed channel, and the results are mapped back into the physical plane. Two geometries are analyzed. One is for a single slot jet directed either into an interior corner formed by two flat plates, or over the external sides of the corner; the flat plates are uniformly heated, and the corner can have various included angles. The heat-transfer coefficient at the stagnation point at the apex of the plates is obtained as a function of the corner angle, and temperature distributions are calculated along the heated walls. The second geometry is an infinite row of uniformly spaced parallel slot jets impinging normally against a uniformly heated plate. The heat-transfer behavior is obtained as a function of the spacing between the jets. Results are given for several jet Peclet numbers from 5 to 50.

  3. Cold-induced vasoconstriction may persist long after cooling ends: an evaluation of multiple cryotherapy units.

    Science.gov (United States)

    Khoshnevis, Sepideh; Craik, Natalie K; Diller, Kenneth R

    2015-09-01

    Localized cooling is widely used in treating soft tissue injuries by modulating swelling, pain, and inflammation. One of the primary outcomes of localized cooling is vasoconstriction within the underlying skin. It is thought that in some instances, cryotherapy may be causative of tissue necrosis and neuropathy via cold-induced ischaemia leading to nonfreezing cold injury (NFCI). The purpose of this study is to quantify the magnitude and persistence of vasoconstriction associated with cryotherapy. Data are presented from testing with four different FDA approved cryotherapy devices. Blood perfusion and skin temperature were measured at multiple anatomical sites during baseline, active cooling, and passive rewarming periods. Local cutaneous blood perfusion was depressed in response to cooling the skin surface with all devices, including the DonJoy (DJO, p = 2.6 × 10(-8)), Polar Care 300 (PC300, p = 1.1 × 10(-3)), Polar Care 500 Lite (PC500L, p = 0.010), and DeRoyal T505 (DR505, p = 0.016). During the rewarming period, parasitic heat gain from the underlying tissues and the environment resulted in increased temperatures of the skin and pad for all devices, but blood perfusion did not change significantly, DJO (n.s.), PC300 (n.s.), PC500L (n.s.), and DR505 (n.s.). The results demonstrate that cryotherapy can create a deep state of vasoconstriction in the local area of treatment. In the absence of independent stimulation, the condition of reduced blood flow persists long after cooling is stopped and local temperatures have rewarmed towards the normal range, indicating that the maintenance of vasoconstriction is not directly dependent on the continuing existence of a cold state. The depressed blood flow may dispose tissue to NFCI.

  4. Evaluation of a Liquid Amine System for Spacecraft Carbon Dioxide Control

    Science.gov (United States)

    Breaux, D. K.; Friedel, P.; Hwang, K. C.; Probert, G.; Ruder, J. M.; Sawamura, L.

    1974-01-01

    The analytical and experimental studies are described which were directed toward the acquisition of basic information on utilizing a liquid amine sorbent for in use in a CO2 removal system for manned spacecraft. Liquid amine systems are successfully used on submarines for control of CO2 generated by the crew, but liquid amines were not previously considered for spacecraft applications due to lack of development of satisfactory rotary phase separators. Developments in this area now make consideration of liquid amines practical for spacecraft system CO2 removal. The following major tasks were performed to evaluate liquid amine systems for spacecraft: (1) characterization, through testing, of the basic physical and thermodynamic properties of the amine solution; (2) determination of the dynamic characteristics of a cocurrent flow absorber; and (3) evaluation, synthesis, and selection of a liquid amine system concept oriented toward low power requirements. A low weight, low power system concept was developed. Numerical and graphical data are accompanied by pertinent observations.

  5. Preapplication safety evaluation report for the Power Reactor Innovative Small Module (PRISM) liquid-metal reactor. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Donoghue, J.E.; Donohew, J.N.; Golub, G.R.; Kenneally, R.M.; Moore, P.B.; Sands, S.P.; Throm, E.D.; Wetzel, B.A. [Nuclear Regulatory Commission, Washington, DC (United States). Associate Directorate for Advanced Reactors and License Renewal

    1994-02-01

    This preapplication safety evaluation report (PSER) presents the results of the preapplication desip review for die Power Reactor Innovative Small Module (PRISM) liquid-mew (sodium)-cooled reactor, Nuclear Regulatory Commission (NRC) Project No. 674. The PRISM conceptual desip was submitted by the US Department of Energy in accordance with the NRC`s ``Statement of Policy for the Regulation of Advanced Nuclear Power Plants`` (51 Federal Register 24643). This policy provides for the early Commission review and interaction with designers and licensees. The PRISM reactor desip is a small, modular, pool-type, liquid-mew (sodium)-cooled reactor. The standard plant design consists of dim identical power blocks with a total electrical output rating of 1395 MWe- Each power block comprises three reactor modules, each with a thermal rating of 471 MWt. Each module is located in its own below-grade silo and is co to its own intermediate heat transport system and steam generator system. The reactors utilize a metallic-type fuel, a ternary alloy of U-Pu-Zr. The design includes passive reactor shutdown and passive decay heat removal features. The PSER is the NRC`s preliminary evaluation of the safety features in the PRISM design, including the projected research and development programs required to support the design and the proposed testing needs. Because the NRC review was based on a conceptual design, the PSER did not result in an approval of the design. Instead it identified certain key safety issues, provided some guidance on applicable licensing criteria, assessed the adequacy of the preapplicant`s research and development programs, and concluded that no obvious impediments to licensing the PRISM design had been identified.

  6. An empirical model of global climate – Part 1: A critical evaluation of volcanic cooling

    Directory of Open Access Journals (Sweden)

    T. Canty

    2013-04-01

    Full Text Available Observed reductions in Earth's surface temperature following explosive volcanic eruptions have been used as a proxy for geoengineering of climate by the artificial enhancement of stratospheric sulfate. Earth cools following major eruptions due to an increase in the reflection of sunlight caused by a dramatic enhancement of the stratospheric sulfate aerosol burden. Significant global cooling has been observed following the four major eruptions since 1900: Santa María, Mount Agung, El Chichón and Mt. Pinatubo, leading IPCC (2007 to state "major volcanic eruptions can, thus, cause a drop in global mean surface temperature of about half a degree Celsius that can last for months and even years". We use a multiple linear regression model applied to the global surface temperature anomaly to suggest that exchange of heat between the atmosphere and ocean, driven by variations in the strength of the Atlantic Meridional Overturning Circulation (AMOC, has been a factor in the decline of global temperature following these eruptions. The veracity of this suggestion depends on whether sea surface temperature (SST in the North Atlantic, sometimes called the Atlantic Multidecadal Oscillation, but here referred to as Atlantic Multidecadal Variability (AMV, truly represents a proxy for the strength of the AMOC. Also, precise quantification of global cooling due to volcanoes depends on how the AMV index is detrended. If the AMV index is detrended using anthropogenic radiative forcing of climate, we find that surface cooling attributed to Mt. Pinatubo, using the Hadley Centre/University of East Anglia surface temperature record, maximises at 0.14 °C globally and 0.32 °C over land. These values are about a factor of 2 less than found when the AMV index is neglected in the model and quite a bit lower than the canonical 0.5 °C cooling usually attributed to Pinatubo. This result is driven by the high amplitude, low frequency component of the AMV index

  7. Subjective evaluation of different ventilation concepts combined with radiant heating and cooling

    DEFF Research Database (Denmark)

    Krajcik, Michal; Tomasi, Roberta; Simone, Angela

    2012-01-01

    with displacement ventilation. Vertical air temperature distribution was more uniform for floor heating than for warm air heating, but there was no significant difference in thermal perception between the two mixing ventilation systems. For the summer conditions the subjects voted warmer than predicted by the PMV...... supplying warm air space heating or by a combination of radiant floor heating and mixing ventilation system. Next two test setups simulated an office room with two occupants during summer, ventilated and cooled by a single displacement ventilation system or by a radiant floor cooling combined...... and about one third preferred more air movement. No significant difference in thermal perception between the two displacement ventilation systems was found....

  8. Second sector cool down

    CERN Multimedia

    2007-01-01

    At the beginning of July, cool-down is starting in the second LHC sector, sector 4-5. The cool down of sector 4-5 may occasionally generate mist at Point 4, like that produced last January (photo) during the cool-down of sector 7-8.Things are getting colder in the LHC. Sector 7-8 has been kept at 1.9 K for three weeks with excellent stability (see Bulletin No. 16-17 of 16 April 2007). The electrical tests in this sector have got opt to a successful start. At the beginning of July the cryogenic teams started to cool a second sector, sector 4-5. At Point 4 in Echenevex, where one of the LHC’s cryogenic plants is located, preparations for the first phase of the cool-down are underway. During this phase, the sector will first be cooled to 80 K (-193°C), the temperature of liquid nitrogen. As for the first sector, 1200 tonnes of liquid nitrogen will be used for the cool-down. In fact, the nitrogen circulates only at the surface in the ...

  9. Performance evaluation on an air-cooled heat exchanger for alumina nanofluid under laminar flow.

    Science.gov (United States)

    Teng, Tun-Ping; Hung, Yi-Hsuan; Teng, Tun-Chien; Chen, Jyun-Hong

    2011-08-09

    This study analyzes the characteristics of alumina (Al2O3)/water nanofluid to determine the feasibility of its application in an air-cooled heat exchanger for heat dissipation for PEMFC or electronic chip cooling. The experimental sample was Al2O3/water nanofluid produced by the direct synthesis method at three different concentrations (0.5, 1.0, and 1.5 wt.%). The experiments in this study measured the thermal conductivity and viscosity of nanofluid with weight fractions and sample temperatures (20-60°C), and then used the nanofluid in an actual air-cooled heat exchanger to assess its heat exchange capacity and pressure drop under laminar flow. Experimental results show that the nanofluid has a higher heat exchange capacity than water, and a higher concentration of nanoparticles provides an even better ratio of the heat exchange. The maximum enhanced ratio of heat exchange and pressure drop for all the experimental parameters in this study was about 39% and 5.6%, respectively. In addition to nanoparticle concentration, the temperature and mass flow rates of the working fluid can affect the enhanced ratio of heat exchange and pressure drop of nanofluid. The cross-section aspect ratio of tube in the heat exchanger is another important factor to be taken into consideration.

  10. Stochastic Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Blaskiewicz, M.

    2011-01-01

    Stochastic Cooling was invented by Simon van der Meer and was demonstrated at the CERN ISR and ICE (Initial Cooling Experiment). Operational systems were developed at Fermilab and CERN. A complete theory of cooling of unbunched beams was developed, and was applied at CERN and Fermilab. Several new and existing rings employ coasting beam cooling. Bunched beam cooling was demonstrated in ICE and has been observed in several rings designed for coasting beam cooling. High energy bunched beams have proven more difficult. Signal suppression was achieved in the Tevatron, though operational cooling was not pursued at Fermilab. Longitudinal cooling was achieved in the RHIC collider. More recently a vertical cooling system in RHIC cooled both transverse dimensions via betatron coupling.

  11. Evaluation of a Sodium–Water Reaction Event Caused by Steam Generator Tubes Break in the Prototype Generation IV Sodium-cooled Fast Reactor

    Directory of Open Access Journals (Sweden)

    Sang June Ahn

    2016-08-01

    Full Text Available The prototype generation IV sodium-cooled fast reactor (PGSFR has been developed by the Korea Atomic Energy Research Institute. This reactor uses sodium as a reactor coolant to transfer the core heat energy to the turbine. Sodium has chemical characteristics that allow it to violently react with materials such as a water or steam. When a sodium–water reaction (SWR occurs due to leakage or breakage of steam generator tubes, high-pressure waves and corrosive reaction products are produced, which threaten the structural integrity of the components of the intermediate heat-transfer system (IHTS and the safety of the primary heat-transfer system (PHTS. In the PGSFR, SWR events are included in the design-basis event. This event should be analyzed from the viewpoint of the integrities of the IHTS and fuel rods. To evaluate the integrity of the IHTS based on the consequences of the SWR, the behaviors of the generated high-pressure waves are analyzed at the major positions of a failed IHTS loop using a sodium–water advanced analysis method-II code. The integrity of the fuel rods must be consistently maintained below the safety acceptance criteria to avoid the consequences of the SWR. The integrity of the PHTS is evaluated using the multidimensional analysis of reactor safety-liquid metal reactor code to model the whole plant.

  12. Safety evaluation for packaging transport of LSA-II liquids in MC-312 cargo tanks

    Energy Technology Data Exchange (ETDEWEB)

    Carlstrom, R.F.

    1996-09-11

    This safety evaluation for packaging authorizes the onsite transfer of bulk LSA-II radioactive liquids in the 222-S Laboratory Cargo Tank and Liquid Effluent Treatment Facility Cargo Tanks (which are U.S. Department of Transportation MC-312 specification cargo tanks) from their operating facilities to tank farm facilities.

  13. Experimental evaluation of dry/wet air-cooled heat exchangers. Progress report

    Energy Technology Data Exchange (ETDEWEB)

    Hauser, S.G.; Gruel, R.L.; Huenefeld, J.C.; Eschbach, E.J.; Johnson, B.M.; Kreid, D.K.

    1982-08-01

    The ultimate goal of this project was to contribute to the development of improved cooling facilities for power plants. Specifically, the objective during FY-81 was to experimentally determine the thermal performance and operating characteristics of an air-cooled heat exchanger surface manufactured by the Unifin Company. The performance of the spiral-wound finned tube surface (Unifin) was compared with two inherently different platefin surfaces (one developed by the Trane Co. and the other developed by the HOETERV Institute) which were previously tested as a part of the same continuing program. Under dry operation the heat transfer per unit frontal area per unit inlet temperature difference (ITD) of the Unifin surface was 10% to 20% below that of the other two surfaces at low fan power levels. At high fan power levels, the performances of the Unifin and Trane surfaces were essentially the same, and 25% higher than the HOETERV surface. The design of the Unifin surface caused a significantly larger air-side pressure drop through the heat exchanger both in dry and deluge operation. Generally higher overall heat transfer coefficients were calculated for the Unifin surface under deluged operation. They ranged from 2.0 to 3.5 Btu/hr-ft/sup 2/-/sup 0/F as compared to less than 2.0 Btu hr-ft/sup 2/-/sup 0/F for the Trane and HOETERV surfaces under similar conditions. The heat transfer enhancement due to the evaporative cooling effect was also measureably higher with the Unifin surface as compared to the Trane surface. This can be primarily attributed to the better wetting characteristics of the Unifin surface. If the thermal performance of the surfaces are compared at equal face velocities, the Unifin surface is as much as 35% better. This method of comparison accounts for the wetting characteristics while neglecting the effect of pressure drop. Alternatively the surfaces when compared at equal pressure drop essentially the same thermal performance.

  14. Prevention and early intervention of anxiety problems in young children: A pilot evaluation of Cool Little Kids Online

    Directory of Open Access Journals (Sweden)

    Amy J. Morgan

    2016-05-01

    Full Text Available Anxiety disorders are common, debilitating, and begin early in life. Early intervention to prevent anxiety disorders in children who are at risk could have long-term impact. The ‘Cool Little Kids’ parenting group program has previously been shown to be efficacious in preventing anxiety disorders in temperamentally inhibited young children. Wider dissemination of the program could be achieved with an internet-based delivery platform, affording greater accessibility and convenience for parents. The aim of this study was to evaluateCool Little Kids Online’, a newly developed online version of the existing parenting group program. Fifty-one parents of children aged 3–6 years were recruited to evaluate the online program's acceptability and preliminary efficacy in reducing inhibited young children's anxiety problems. Parents were randomized to receive either a clinician-supported version or an unsupported version of the program. Parents had 10 weeks to access the program and completed questionnaires at baseline and post-intervention. Both groups showed medium-to-large reductions in children's anxiety symptoms, emotional symptoms, number of child anxiety diagnoses, and improvements in life interference from anxiety. The effect of clinician support was inconsistent and difficult to interpret. Parents reported high levels of satisfaction with the program. These encouraging results indicate that the online version is acceptable and useful for parents with temperamentally inhibited young children. Cool Little Kids Online may be a promising direction for improving access to an evidence-based prevention and early intervention program for child anxiety problems. A large randomized trial is warranted to further evaluate efficacy.

  15. Evaluation of proposed German safety criteria for high-temperature gas-cooled reactors

    Energy Technology Data Exchange (ETDEWEB)

    Barsell, A.W.

    1980-05-01

    This work reviews proposed safety criteria prepared by the German Bundesministerium des Innern (BMI) for future licensing of gas-cooled high-temperature reactor (HTR) concepts in the Federal Republic of Germany. Comparison is made with US General Design Criteria (GDCs) in 10CFR50 Appendix A and with German light water reactor (LWR) criteria. Implications for the HTR design relative to the US design and safety approach are indicated. Both inherent characteristics and design features of the steam cycle, gas turbine, and process heat concepts are taken into account as well as generic design options such as a pebble bed or prismatic core.

  16. Performance Evaluation of Liquid Fuel 2-Dimethyl Amino Ethyl Azide (DMAZ) with Liquid Oxidizers

    Science.gov (United States)

    Pakdehi, Shahram G.; Ajdari, S.; Hashemi, A.; Keshavarz, Mohammad Hossein

    2015-01-01

    2-Dimethyl amino ethyl azide (DMAZ) has attracted much attention as a suitable liquid fuel replacement for monomethyl hydrazine (MMH) and unsymmetrical dimethyl hydrazine (UDMH) in propellant systems because, in contrast to these fuels, it is nontoxic. In this article, performance and ignition delay of DMAZ were studied with common liquid oxidizers including inhibited red fuming nitric acid (IRFNA), anhydrous nitric acid, dinitrogen tetroxide (N2O4), hydrogen peroxide (H2O2), liquid oxygen (LOX), and mixed oxides of nitrogen (MON). Results showed that combustion of DMAZ and LOX provides the highest specific impulse (305.8 s) compared to the other mentioned oxidizers. Moreover, DMAZ and H2O2 gave the highest density specific impulse (360.2 s) at an optimum oxidizer-to-fuel ratio due to the higher density of hydrogen peroxide. Furthermore, a mixture of DMAZ and N2O4 had the minimum ignition delay time (68 ms). Therefore, it seems that the DMAZ-N2O4 propellant combination is suitable for space systems.

  17. Fuel and Core Design Options to Overcome the Heavy Metal Loading Limit and Improve Performance and Safety of Liquid Salt Cooled Reactors

    Energy Technology Data Exchange (ETDEWEB)

    Petrovic, Bojan [Georgia Inst. of Technology, Atlanta, GA (United States); Maldonado, Ivan [Univ. of Tennessee, Knoxville, TN (United States)

    2016-04-14

    The research performed in this project addressed the issue of low heavy metal loading and the resulting reduced cycle length with increased refueling frequency, inherent to all FHR designs with solid, non-movable fuel based on TRISO particles. Studies performed here focused on AHTR type of reactor design with plate (“plank”) fuel. Proposal to FY12 NEUP entitled “Fuel and Core Design Options to Overcome the Heavy Metal Loading Limit and Improve Performance and Safety of Liquid Salt Cooled Reactors” was selected for award, and the 3-year project started in August 2012. A 4-month NCE was granted and the project completed on December 31, 2015. The project was performed by Georgia Tech (Prof. Bojan Petrovic, PI) and University of Tennessee (Prof. Ivan Maldonado, Co-PI), with a total funding of $758,000 over 3 years. In addition to two Co-PIs, the project directly engaged 6 graduate students (at doctoral or MS level) and 2 postdoctoral researchers. Additionally, through senior design projects and graduate advanced design projects, another 23 undergraduate and 12 graduate students were exposed to and trained in the salt reactor technology. We see this as one of the important indicators of the project’s success and effectiveness. In the process, 1 journal article was published (with 3 journal articles in preparation), together with 8 peer-reviewed full conference papers, 8 peer-reviewed extended abstracts, as well as 1 doctoral dissertation and 2 master theses. The work included both development of models and methodologies needed to adequately analyze this type of reactor, fuel, and its fuel cycle, as well as extensive analyses and optimization of the fuel and core design.

  18. Critical evaluation of high-temperature gas-cooled reactors applicable to coal conversion

    Energy Technology Data Exchange (ETDEWEB)

    Spiewak, I.; Jones, J.E. Jr.; Rittenhouse, P.L.; DeStefano, J.R.; Delene, J.G.

    1975-12-01

    A critical review is presented of the technology and costs of very high-temperature gas-cooled reactors (VHTRs) applicable to nuclear coal conversion. Coal conversion processes suitable for coupling to reactors are described. Vendor concepts of the VHTR are summarized. The materials requirements as a function of process temperature in the range 1400 to 2000/sup 0/F are analyzed. Components, environmental and safety factors, economics and nuclear fuel cycles are reviewed. It is concluded that process heat supply in the range 1400 to 1500/sup 0/F could be developed with a high degree of assurance. Process heat at 1600/sup 0/F would require considerably more materials development. While temperatures up to 2000/sup 0/F appear to be attainable, considerably more research and risk were involved. A demonstration plant would be required as a step in the commercialization of the VHTR.

  19. Maryland Power Plant Cooling-Water Intake Regulations and their Application in Evaluation of Adverse Environmental Impact

    Directory of Open Access Journals (Sweden)

    Richard McLean

    2002-01-01

    Full Text Available Maryland’s cooling-water intake and discharge regulations, the Code of Maryland Regulations (COMAR 26.08.03, stem from Sections 316(a and (b of the Clean Water Act (CWA. COMAR 26.08.03.05 and litigative and administrative rulings stipulate that the location, design, construction, and capability of cooling-water intake structures must reflect the best technology available (BTA for minimizing adverse environmental impacts (AEIs, providing that the costs of implementing the BTA are not wholly disproportionate to the expected environmental benefits. Maryland law exempts facilities that withdraw less than 10 million gallons/day (MGD and less than 20% of stream or net flow by the intake. If not exempt, BTA must be installed if the cost of doing so is less than five times the value of fish impinged annually. Through site-specific studies and the use of a Spawning and Nursery Area of Consequence (SNAC model applied to Representative Important Species, several power plants were evaluated to determine if they have had an adverse effect on spawning and nursery areas of consequence. Examples of application of the Maryland law to a number of power plants in the state are presented, together with the outcome of their evaluation.

  20. Effect of soda lime flux on evaluation of the critical cooling rate of Pd82Si18 amorphous ribbon

    Directory of Open Access Journals (Sweden)

    Xutong Wang

    2017-09-01

    Full Text Available Herein, we propose an experimental method based on the Barandiaran–Colmenero relation for evaluating the critical cooling rate (Rc of Pd82Si18 amorphous ribbon. In this method, to determine the inherent Rc of glass ribbon, heterogeneous nucleation is suppressed during the differential scanning calorimeter measurement process by adding soda lime flux. The Rc values of Pd82Si18 amorphous ribbon were determined before and after soda lime treatment. The experimental results indicate that the Rc values of the treated and non-treated ribbon are 10.27 and 148.39 K/s, respectively. The Rc value of the treated sample is in good agreement with a previous experimental result. Johnson’s relation gives Rc = 22.86 K/s, which confirms the validity of the present results. The results indicate that soda lime flux greatly suppresses heterogeneous nucleation during the measurement process and the inherent Rc of Pd82Si18 is revised. This method provides a new way for evaluating the critical cooling rate by suppressing heterogeneous nucleation.

  1. LHC cooling gains ground

    CERN Multimedia

    Huillet-Miraton Catherine

    The nominal cryogenic conditions of 1.9 K have been achieved in sectors 5-6 and 7-8. This means that a quarter of the machine has reached the nominal conditions for LHC operation, having attained a temperature of below 2 K (-271°C), which is colder than interstellar space! Elsewhere, the cryogenic system in Sector 8-1 has been filled with liquid helium and cooled to 2K and will soon be available for magnet testing. Sectors 6-7 and 2-3 are being cooled down and cool-down operations have started in Sector 3-4. Finally, preparations are in hand for the cool-down of Sector 1-2 in May and of Sector 4-5, which is currently being consolidated. The LHC should be completely cold for the summer. For more information: http://lhc.web.cern.ch/lhc/Cooldown_status.htm.

  2. Dynamic data evaluation for solid-liquid equilibria

    DEFF Research Database (Denmark)

    Cunico, Larissa; Ceriani, Roberta; Kang, Jeong Won

    The accuracy and reliability of the measured data sets to be used in regression of model parameters is an important issue related to modeling of phase equilibria. It is clear that good parameters for any model cannot be obtained from low quality data. A thermodynamic consistency test for solid...... of the developed tests were based in the quality tests proposed for VLE data by Kang et al. [3] and a methodology that combines solute activity coefficients in the liquid phase at infinite dilution and a theoretically based term to account for the non-ideality in dilute solutions are discussed. In this work, case...

  3. Performance evaluation of organic emulsion liquid membrane on phenol removal

    CERN Document Server

    Ng, Y S; Hashim, M A

    2014-01-01

    The percentage removal of phenol from aqueous solution by emulsion liquid membrane and emulsion leakage was investigated experimentally for various parameters such as membrane:internal phase ratio, membrane:external phase ratio, emulsification speed, emulsification time, carrier concentration, surfactant concentration and internal agent concentration. These parameters strongly influence the percentage removal of phenol and emulsion leakage. Under optimum membrane properties, the percentage removal of phenol was as high as 98.33%, with emulsion leakage of 1.25%. It was also found that the necessity of carrier for enhancing phenol removal was strongly dependent on the internal agent concentration.

  4. Advanced Gas Cooled Nuclear Reactor Materials Evaluation and Development Program. Progress report, January 1, 1980-March 31, 1980

    Energy Technology Data Exchange (ETDEWEB)

    1980-06-25

    Results are presented of work performed on the Advanced Gas-Cooled Nuclear Reactor Materials Evaluation and Development Program. The objectives of this program are to evaluate candidate alloys for Very High Temperature Reactor (VHTR) Nuclear Process Heat (NPH) and Direct Cycle Helium Turbine (DCHT) applications, in terms of the effect of simulated reactor primary coolant (helium containing small amounts of various other gases), high temperatures, and long time exposures, on the mechanical properties and structural and surface stability of selected candidate alloys. A second objective is to select and recommend materials for future test facilities and more extensive qualification programs. Included are the activities associated with the status of the simulated reactor helium supply system, testing equipment and gas chemistry analysis instrumentation and equipment. The progress in the screening test program is described, including screening creep results and metallographic analysis for materials thermally exposed or tested at 750, 850, and 950/sup 0/C.

  5. Advanced gas cooled nuclear reactor materials evaluation and development program. Progress report, January 1, 1979-March 31, 1979

    Energy Technology Data Exchange (ETDEWEB)

    1979-07-19

    This report presents the results of work performed from January 1, 1979 through March 31, 1979 on the Advanced Gas Cooled Nuclear Reactor Materials Evaluation and Development Program. The objectives of this program are to evaluate candidate alloys for Very High Temperature Reactor (VHTR) Nuclear Process Heat (NPH) and Direct Cycle Helium Turbine (DCHT) applications, in terms of the effect of simulated reactor primary coolant (helium containing small amounts of various other gases), high temperatures, and long time exposures, on the mechanical properties and structural and surface stability of selected candidate alloys. Work covered in this report includes the activities associated with the creep-rupture testing of the test materials for the purpose of verifying the stresses selected for the screening creep test program, and the status of the simulated reactor helium supply system, testing equipment, and gas chemistry analysis instrumentation and equipment.

  6. Advanced gas cooled nuclear reactor materials evaluation and development program. Progress report, September 23, 1976--December 31, 1976

    Energy Technology Data Exchange (ETDEWEB)

    1977-01-01

    This report presents the results of work performed from September 23, 1976 through December 31, 1976 on the Advanced Gas Cooled Nuclear Reactor Materials Evaluation and Development Program. The objectives of this program are to evaluate candidate alloys for Very High Temperature Reactor (VHTR) Process Heat and Direct Cycle Helium Turbine (DCHT) applications, in terms of the affect of simulated reactor primary coolant (impure Helium), high temperatures, and long time exposures, on the mechanical properties and structural and surface stability of selected candidate alloys. A second objective is to select and recommend materials for future test facilities and more extensive qualification programs. Work covered in this report includes progress to date on alloy selection for VHTR Nuclear Process Heat (NPH) applications and for DCHT applications. The present status on the simulated reactor helium loop design and on designs for the testing and analysis facilities and equipment is discussed.

  7. Advanced Gas Cooled Nuclear Reactor Materials Evaluation and Development Program. Progress report, October 1, 1978--December 31, 1978

    Energy Technology Data Exchange (ETDEWEB)

    1979-03-09

    Results of work performed from October 1, 1978 through December 31, 1978 on the Advanced Gas Cooled Nuclear Reactor Materials Evaluation and Development Program is presented. Objectives are to evaluate candidate alloys for Very High Temperature Reactor (VHTR) Nuclear Process Heat (NPH) and Direct Cycle Helium Turbine (DCHT) applications, in terms of the effect of simulated reactor primary coolant (helium containing small amounts of various other gases), high temperatures, and long time exposures, on the mechanical properties and structural and surface stability of selected candidate alloys, and selection of materials for future test facilities and more extensive qualification programs. The activities associated with the characterization of the materials for the screening test program, and the status of the simulated reactor helium supply system, testing equipment, and gas chemistry analysis instrumentation and equipment are included. The status of the data management system is presented.

  8. Advanced gas cooled nuclear reactor materials evaluation and development program. Progress report, July 1--September 30, 1978

    Energy Technology Data Exchange (ETDEWEB)

    1978-11-24

    Results of work performed from July 1, 1978 through September 30, 1978 on the Advanced Gas Cooled Nuclear Reactor Materials Evaluation and Development Program are presented. Candidate alloys were evaluated for Very High Temperature Reactor Nuclear Process Heat (NPH) and Direct Cycle Helium Turbine (DCHT) applications, in terms of the affect of simulated reactor primary coolant (Helium containing small amounts of various other gases), the high temperatures, and long time exposures, on the mechanical properties and structural and surface stability of selected candidate alloys. The activities associated with the characterization of the materials for the screening test program are reported, i.e., test specimen preparation, information from the materials characterization tests performed by General Electric, and the status of the simulated reactor helium supply system, testing equipment, and gas chemistry analysis instrumentation and equipment. The status of the data management system is presented.

  9. Advanced Gas-Cooled Nuclear Reactor Materials Evaluation and Development Program. Progress report, July 1, 1979-September 30, 1979

    Energy Technology Data Exchange (ETDEWEB)

    1980-03-07

    The results of work performed from July 1, 1979 through September 30, 1979 on the Advanced Gas-Cooled Nuclear Reactor Materials Evaluation and Development Program are presented. The objectives of this program are to evaluate candidate alloys for Very High Temperature Reactor (VHTR) Nuclear Process Heat (NPH) and Direct Cycle Helium Turbine (DCHT) applications, in terms of the effect of simulated reactor primary coolant (helium containing small amounts of various other gases), high temperatures, and long time exposures, on the mechanical properties and structural and surface stability of selected candidate alloys. A second objective is to select and recommend materials for future test facilities and more extensive qualification programs. Work covered in this report includes the activities associated with the status of the simulated reactor helium supply system, testing equipment, and gas chemistry analysis instrumentation and equipment. The status of the data management system is presented. In addition, the progress in the screening test program is described.

  10. Advanced Gas-Cooled Nuclear Reactor Materials Evaluation and Development Program. Progress report, April 1, 1979-June 30, 1979

    Energy Technology Data Exchange (ETDEWEB)

    1980-01-25

    The results are presented of work performed on the Advanced Gas-Cooled Nuclear Reactor Materials Evaluation and Development Program. The objectives of this program are to evaluate candidate alloys for Very High Temperature Reactor (VHTR) Nuclear Process Heat (NPH) and Direct Cycle Helium Turbine (DCHT) applications, in terms of the effect of simulated reactor primary coolant (helium containing small amounts of various other gases), high temperatures, and long time exposures, on the mechanical properties and structural and surface stability of selected candidate alloys. A second objective is to select and recommend materials for future test facilities and more extensive qualification programs. Work covered in this report includes the activities associated with the status of the simulated reactor helium supply system, testing equipment, and gas chemistry analysis instrumentation and equipment. The status of the data management system is presented. In addition, the progress in the screening test program is described.

  11. Designing of the cooling vest from paraffin compounds and evaluation of its impact under laboratory hot conditions

    Directory of Open Access Journals (Sweden)

    Saeid Yazdanirad

    2016-01-01

    Conclusions: The designed cooling vest with low cost can be used to prevent thermal strain and to increase the physiological stability against the heat. However, the latent heat of this cooling vest was low.

  12. Evaluation of solar thermal driven cooling system in office buildings in Saudi Arabia

    Science.gov (United States)

    Linjawi, Majid T.; Talal, Qazi; Al-Sulaiman, Fahad A.

    2017-11-01

    In this study solar driven absorption chiller is used to reduce the peak cooling load in office buildings in Saudi Arabia for different selected cities. The study is conducted for six cities of Abha, Dhahran, Hail, Jeddah, Nejran and Riyadh under three operating durations of 4, 6, and 8 hours using flat plate or evacuated tube collectors. The energy analysis concluded that flat plate collectors are better than evacuated tube collectors. However, the results from economic analysis suggest that while proposing a gas fired absorption chiller will reduce running costs, further reduction by using solar collectors is not feasible because of its high initial cost. At the best case scenario the Net Present Value of a 10 Ton Absorption chiller operated by natural gas boiler and two large flat plate collectors (12m2 each) running for 8 hours/day, 5days/week has a value of 117,000 and Internal Rate of Return (IRR) of 12%. Solar driven absorption chiller could be more feasible if the gas prices increases or the solar collector prices decreases significantly. Finally, government economic incentives and taxes are recommended to provide a boost for the feasibility of such projects.

  13. Safety Design and Evaluation in a Large-Scale Japan Sodium-Cooled Fast Reactor

    Directory of Open Access Journals (Sweden)

    H. Yamano

    2012-01-01

    Full Text Available As a next-generation plant, a large-scale Japan sodium-cooled fast reactor (JSFR adopts a number of innovative technologies in order to achieve economic competitiveness, enhanced reliability, and safety. This paper describes safety requirements for JSFR conformed to the defense-in-depth principle in IAEA. Specific design features of JSFR are a passive reactor shutdown system and a recriticality-free concept against anticipated transients without scram (ATWS in design extension conditions (DECs. A fully passive decay heat removal system with natural circulation is also introduced for design-basis events (DBEs and DECs. In this paper, the safety design accommodation in JSFR was validated by safety analyses for representative DBEs: primary pump seizure and long-term loss-of-offsite power accidents. The safety analysis also showed the effectiveness of the passive shutdown system against a typical ATWS. Severe accident analysis supported by safety experiments and phenomenological consideration led to the feasibility of in-vessel retention without energetic recriticality. Moreover, a probabilistic safety assessment indicated to satisfy the risk target.

  14. EVALUATION OF METHODS OF ANALYSIS TO DETERMINE THE SOMATIC CELL COUNT IN RAW MILK, KEPT IN THE COOLING TANK

    Directory of Open Access Journals (Sweden)

    Manoel Pereira Neto

    2014-06-01

    Full Text Available We analyzed the quality of raw milk from eight dairy property in Rio Grande do Norte, Brazil, stored in a cooling tank, in order to evaluate methods for determining somatic cell counts (SCC. The Somaticell® kit and a portable Direct Cell Counter (DCC were compared with each other and with the MilkoScanTM FT+ (FOSS Denmark, which uses Fourier Transform Infrared Spectroscopy (FTIS. Direct cell counter data were processed for somatic cell scores (log-transformed somatic cell count and analyzed with the SAS®, Statistical Analysis System. Comparison of means and correlation of somatic cell scores were conducted using Pearson’s correlation coefficient and the Tukey Test at 1%. No significant difference was observed for comparison of means. The correlation between somatic cell scores was significant, that is, 0.907 and 0.876 between the MilkoScanTM FT + and the Somaticell® kit and Direct Cell Count (DCC respectively, and 0.943 between the Somaticell® kit and Direct Cell Count (DCC. The methods can be recommended for monitoring the quality of raw milk kept in a cooling tank in the production unit.

  15. Status report. KfK contribution to the development of DEMO-relevant test blankets for NET/ITER. Pt. 1: Self-cooled liquid metal breeder blanket. Vol. 1. Summary

    Energy Technology Data Exchange (ETDEWEB)

    Malang, S.; Reimann, J.; Sebening, H. [comps.; Barleon, L.; Bogusch, E.; Bojarsky, E.; Borgstedt, H.U.; Buehler, L.; Casal, V.; Deckers, H.; Feuerstein, H.; Fischer, U.; Frees, G.; Graebner, H.; John, H.; Jordan, T.; Kramer, W.; Krieg, R.; Lenhart, L.; Malang, S.; Meyder, R.; Norajitra, P.; Reimann, J.; Schwenk-Ferrero, A.; Schnauder, H.; Stieglitz, R.; Oschinski, J.; Wiegner, E.

    1991-12-01

    A self-cooled liquid metal breeder blanket for a fusion DEMO-reactor and the status of the development programme is described as a part of the European development programme of DEMO relevant test blankets for NET/ITER. Volume 1 (KfK 4907) contains a summary, Volume 2 (KfK 4908) a more detailed version of the report. Both volumes contain sections on previous studies on self-cooled liquid metal breeder blankets, the reference blanket design for a DEMO-reactor, a typical test blanket design including the ancillary loop system and the building requirements for NET/ITER together with the present status of the associated R and D-programme in the fields of neutronics, magnetohydrodynamics, tritium removal and recovery, liquid metal compatibility and purification, ancillary loop system, safety and reliability. An outlook is given regarding the required R and D-programme for the self-cooled liquid metal breeder blanket prior to tests in NET/ITER and the relevant test programme to be performed in NET/ITER. (orig.). [Deutsch] Ein selbstgekuehltes Fluessigmetall-Brutblanket fuer einen DEMO Fusionsreaktor und der Stand der Entwicklungsarbeiten, als Teil des Europaeischen Entwicklungsprogramms fuer ein DEMO-relevantes Testblanket fuer NET/ITER werden beschrieben. Band 1 (KfK 4907) enthaelt die Zusammenfassung und Band 2 (KfK 4708) den detaillierten Bericht. In den beiden Berichten werden bisher durchgefuehrte Untersuchungen fuer selbstgekuehlte Fluessigmetallbrutblankets beschrieben. Es werden der Referenzentwurf fuer das DEMO-Reaktorblanket und ein typischer Entwurf fuer ein Testblanket in NET/ITER mit den dazugehoerigen externen Kreislaeufen und einem Komponentenaufstellungsplan vorgestellt. Der augenblickliche Stand der Forschungs- und Entwicklungsarbeiten bezueglich: Neutronenrechnungen, Magnetohydrodynamik (MHD), Tritiumgewinnung, Bestaendigkeit im Fluessigmetall, Fluessigmetallreinigung sowie Sicherheit und Zuverlaessigkeit der Kreislaeufe wird aufgezeigt. Es wird ein

  16. Status report. KfK contribution to the development of DEMO-relevant test blankets for NET/ITER. Pt. 1: Self-cooled liquid metal breeder blanket. Vol. 2. Detailed version

    Energy Technology Data Exchange (ETDEWEB)

    John, H.; Malang, S.; Sebening, H. [comps.; Barleon, L.; Bojarsky, E.; Borgstedt, H.U.; Buehler, L.; Casal, V.; Deckers, H.; Feuerstein, H.; Fischer, U.; Frees, G.; Graebner, H.; John, H.; Jordan, T.; Kramer, W.; Krieg, R.; Lenhart, L.; Meyder, R.; Norajitra, P.; Reiser, H.; Reimann, J.; Schwenk-Ferrero, A.; Schnauder, H.; Stieglitz, R.; Oschinski, J.; Wiegner, E. [Kernforschungszentrum Karlsruhe GmbH (Germany). Projekt Kernfusion; Bogusch, E. [Interatom GmbH, Bergisch Gladbach (Germany)

    1991-12-01

    A self-cooled liquid metal breeder blanket for a fusion DEMO-reactor and the status of the development programme is described as a part of the European development programme of DEMO relevant test blankets for NET/ITER. Volume 1 (KfK 4907) contains a summary. Volume 2 (KfK 4908) a more detailed version of the report. Both volumes contain sections on previous studies on self-cooled liquid metal breeder blankets, the reference blanket design for a DEMO-reactor, a typical test blanket design including the ancillary loop system and the building requirements for NET/ITER together with the present status of the associated RandD-programme in the fields of neutronics, magnetohydrodynamics, tritium removal and recovery, liquid metal compatibility and purification, ancillary loop system, safety and reliability. An outlook is given regarding the required RandD-programme for the self-cooled liquid metal breeder blanket prior to tests in NET/ITER and the relevant test programme to be performed in NET/ITER. (orig.). [Deutsch] Ein selbstgekuehltes Fluessigmetall-Brutblanket fuer einen DEMO Fusionsreaktor und der Stand der Entwicklungsarbeiten, als Teil des Europaeischen Entwicklungsprogramms fuer ein DEMO-relevantes Testblanket fuer NET/ITER werden beschrieben. Band 1 (KfK 4907) enthaelt die Zusammenfassung und Band 2 (KfK 4708) den detaillierten Bericht. In den beiden Berichten werden bisher durchgefuehrte Untersuchungen fuer selbstgekuehlte Fluessigmetallbrutblankets beschrieben. Es werden der Referenzentwurf fuer das DEMO-Reaktorblanket und ein typischer Entwurf fuer ein Testblanket in NET/ITER mit den dazugehoerigen externen Kreislaeufen und einem Komponentenaufstellungsplan vorgestellt. Der augenblickliche Stand der Forschungs- und Entwicklungsarbeiten bezueglich: Neutronenrechnungen, Magnetohydrodynamik (MHD), Tritiumgewinnung, Bestaendigkeit im Fluessigmetall, Fluessigmetallreinigung und Sicherheit und Zuverlaessigkeit der Kreislaeufe wird aufgezeigt. Es wird ein Ausblick

  17. An experiment to evaluate liquid hydrogen storage in space

    Science.gov (United States)

    Eberhardt, R. N.; Fester, D. A.; Johns, W. A.; Marino, J. S.

    1981-01-01

    The design and verification of a Cryogenic Fluid Management Experiment for orbital operation on the Shuttle is described. The experiment will furnish engineering data to establish design criteria for storage and supply of cryogenic fluids, mainly hydrogen, for use in low gravity environments. The apparatus comprises an LAD (liquid acquisition device) and a TVS (thermodynamic vent system). The hydrogen will be either vented or forced out by injected helium and the flow rates will be monitored. The data will be compared with ground-based simulations to determine optimal flow rates for the pressurizing gas and the release of the cryogenic fluid. It is noted that tests on a one-g, one-third size LAD system are under way.

  18. Synthesis of benzoazole ionic liquids and evaluation of their antimicrobial activity

    Directory of Open Access Journals (Sweden)

    Łukasz Czekański

    2014-07-01

    Full Text Available A new class of chemicals composed not of molecules but ions, an organic cation and an organic or inorganic anion, has recently attracted attention. When these new kind of salts are in the liquid state below 100 oC, they are named ionic liquids (ILs. In this work, the synthesis of ionic liquids obtained from a 2-mercaptobenzimidazole, 2-mercaptobenzoxazole or 2-mercaptobenzothiazole anion and 1-alkyl-3-methylimidazolium or choline cation are described. The antimicrobial activity against several Gram-positive and Gram-negative bacteria and a yeast was also evaluated.

  19. Energy and Exergy Analysis for Improving the Energy Performance of Air-Cooled Liquid Chillers by Different Condensing-Coil Configurations

    Directory of Open Access Journals (Sweden)

    Tzong-Shing Lee

    2012-03-01

    Full Text Available This study constructed a parameter analysis for improving the energy performance of air-cooled water chillers by altering the angle configuration of the condenser coils. The mathematical models for energy and exergy analyses of the individual components and overall system of air-cooled water chillers are presented. This study investigated the potential enhancement of performance efficiency in air-cooled chillers and the energy conversion efficiency of each component, in order to determine how the angle configuration of condenser coils influences chiller performance. This study found that the overall performance of an air-cooled chiller could be improved by approximately 3.4%, and the total irreversibility could be reduced by approximately 2.7%. With each 1% increase in average wind speed over the condenser coils, the overall performance of an air‑cooled chiller was found to be enhanced by approximately 0.43%, and its total irreversibility was reduced by approximately 0.35%. The results of this study can be effectively applied to air-cooled condenser units, and can provide an important basis of reference for developing and enhancing the energy efficiency of air-cooled chillers.

  20. Evaluation of mercury in liquid waste processing facilities - Phase I report

    Energy Technology Data Exchange (ETDEWEB)

    Jain, V. [Savannah River Site (SRS), Aiken, SC (United States); Occhipinti, J. E. [Savannah River Site (SRS), Aiken, SC (United States); Shah, H. [Savannah River Site (SRS), Aiken, SC (United States); Wilmarth, W. R. [Savannah River Site (SRS), Aiken, SC (United States); Edwards, R. E. [Savannah River Site (SRS), Aiken, SC (United States)

    2015-07-01

    This report provides a summary of Phase I activities conducted to support an Integrated Evaluation of Mercury in Liquid Waste System (LWS) Processing Facilities. Phase I activities included a review and assessment of the liquid waste inventory and chemical processing behavior of mercury using a system by system review methodology approach. Gaps in understanding mercury behavior as well as action items from the structured reviews are being tracked. 64% of the gaps and actions have been resolved.

  1. Evaluation of Mercury in Liquid Waste Processing Facilities - Phase I Report

    Energy Technology Data Exchange (ETDEWEB)

    Jain, V. [Savannah River Site (SRS), Aiken, SC (United States); Occhipinti, J. [Savannah River Site (SRS), Aiken, SC (United States); Shah, H. [Savannah River Site (SRS), Aiken, SC (United States); Wilmarth, B. [Savannah River Site (SRS), Aiken, SC (United States); Edwards, R. [Savannah River Site (SRS), Aiken, SC (United States)

    2015-07-01

    This report provides a summary of Phase I activities conducted to support an Integrated Evaluation of Mercury in Liquid Waste System (LWS) Processing Facilities. Phase I activities included a review and assessment of the liquid waste inventory and chemical processing behavior of mercury using a system by system review methodology approach. Gaps in understanding mercury behavior as well as action items from the structured reviews are being tracked. 64% of the gaps and actions have been resolved.

  2. Method for evaluating the system instrumentation for loose part detection in the primary cooling circuit of French PWRs

    Energy Technology Data Exchange (ETDEWEB)

    Gerardin, J.P.; Donnette, J.E

    1995-05-01

    The purpose of the loose part detection system is to trigger an alarm whenever it is warranted, to localize, and to provide information on the type of loose part involved and the damages it may provoke. It is therefore indispensable to have efficient instrumentation, beginning with the sensors which must provide us with a response to all mechanical impacts in natural trapping areas (reactor vessel and steam generator water box). A series of mass- and energy-calibrated impacts have been generated on 45 points in the primary cooling system of a nuclear plant unit in the startup phase. This test provided insights into the relationship between sensor signals and various impact parameters such as velocity of impact or loose part mass. Once these parameters were known, it was possible to define a method for evaluating the detection threshold of sensors depending on the way they are mounted. (author)

  3. Computational fluid dynamics evaluation of liquid food thermal process in a brick shaped package

    Directory of Open Access Journals (Sweden)

    Pedro Esteves Duarte Augusto

    2012-03-01

    Full Text Available Food processes must ensure safety and high-quality products for a growing demand consumer creating the need for better knowledge of its unit operations. The Computational Fluid Dynamics (CFD has been widely used for better understanding the food thermal processes, and it is one of the safest and most frequently used methods for food preservation. However, there is no single study in the literature describing thermal process of liquid foods in a brick shaped package. The present study evaluated such process and the influence of its orientation on the process lethality. It demonstrated the potential of using CFD to evaluate thermal processes of liquid foods and the importance of rheological characterization and convection in thermal processing of liquid foods. It also showed that packaging orientation does not result in different sterilization values during thermal process of the evaluated fluids in the brick shaped package.

  4. Information technology equipment cooling system

    Science.gov (United States)

    Schultz, Mark D.

    2014-06-10

    According to one embodiment, a system for removing heat from a rack of information technology equipment may include a sidecar indoor air to liquid heat exchanger that cools warm air generated by the rack of information technology equipment. The system may also include a liquid to liquid heat exchanger and an outdoor heat exchanger. The system may further include configurable pathways to connect and control fluid flow through the sidecar heat exchanger, the liquid to liquid heat exchanger, the rack of information technology equipment, and the outdoor heat exchanger based upon ambient temperature and/or ambient humidity to remove heat from the rack of information technology equipment.

  5. Comparison of burnout characteristics in jet impingement cooling and stray cooling

    Science.gov (United States)

    Cho, C. S. K.; Wu, K.

    Characteristics of spray cooling and jet impingement methods were investigated. The jet impingement cooling method created a large dry area on the test surface when the burnout heat flux was approached. In the spray cooling method, a liquid film with nucleate boiling was maintained for the entire experiment until a burnout was occurred. The spray cooling method produced a higher burnout heat flux than the jet impingement cooling method for the same liquid flow rate. In the spray cooling method, sprayed droplet velocity was a parameter for determining the burnout heat flux. The burnout heat flux in jet impingement cooling also showed dependency on the liquid jet velocity. Results of two methods for cooling the surface area were compared and correlated with the Weber number.

  6. Experimental evaluation of a pre-industrial air-cooled LiBr-H2O small capacity absorption machine

    OpenAIRE

    Farnós Baulenas, Joan; Castro González, Jesús; García-Rivera, Eduardo; Oliva Llena, Asensio; Chiva Segura, Jorge

    2011-01-01

    The paper studies thermal design and describes the experimental set-up of a domestic-scale prototype experimental cooling system based on a 7kW of nominal capacity single-stage small LiBr-H2O air-cooled absorption machine. The paper illustrates the characteristics based on a methodical procedure for the design and sizing of the small capacity air-cooled absorption machine. Peer Reviewed

  7. Ventilative Cooling

    DEFF Research Database (Denmark)

    Heiselberg, Per Kvols; Kolokotroni, Maria

    -of-the-art of ventilative cooling potentials and limitations, its consideration in current energy performance regulations, available building components and control strategies and analysis methods and tools. In addition, the report provides twenty six examples of operational buildings using ventilative cooling ranging from...

  8. Evaluating the Performance of a New Model for Predicting the Growth of Clostridium perfringens in Cooked, Uncured Meat and Poultry Products under Isothermal, Heating, and Dynamically Cooling Conditions.

    Science.gov (United States)

    Huang, Lihan

    2016-07-01

    Clostridium perfringens type A is a significant public health threat and its spores may germinate, outgrow, and multiply during cooling of cooked meats. This study applies a new C. perfringens growth model in the USDA Integrated Pathogen Modeling Program-Dynamic Prediction (IPMP Dynamic Prediction) Dynamic Prediction to predict the growth from spores of C. perfringens in cooked uncured meat and poultry products using isothermal, dynamic heating, and cooling data reported in the literature. The residual errors of predictions (observation-prediction) are analyzed, and the root-mean-square error (RMSE) calculated. For isothermal and heating profiles, each data point in growth curves is compared. The mean residual errors (MRE) of predictions range from -0.40 to 0.02 Log colony forming units (CFU)/g, with a RMSE of approximately 0.6 Log CFU/g. For cooling, the end point predictions are conservative in nature, with an MRE of -1.16 Log CFU/g for single-rate cooling and -0.66 Log CFU/g for dual-rate cooling. The RMSE is between 0.6 and 0.7 Log CFU/g. Compared with other models reported in the literature, this model makes more accurate and fail-safe predictions. For cooling, the percentage for accurate and fail-safe predictions is between 97.6% and 100%. Under criterion 1, the percentage of accurate predictions is 47.5% for single-rate cooling and 66.7% for dual-rate cooling, while the fail-dangerous predictions are between 0% and 2.4%. This study demonstrates that IPMP Dynamic Prediction can be used by food processors and regulatory agencies as a tool to predict the growth of C. perfringens in uncured cooked meats and evaluate the safety of cooked or heat-treated uncured meat and poultry products exposed to cooling deviations or to develop customized cooling schedules. This study also demonstrates the need for more accurate data collection during cooling. Published 2016. This article is a U.S. Government work and is in the public domain in the USA.

  9. An evaluation of cis- and trans-retinol contents in juices using dispersive liquid-liquid microextraction coupled to liquid chromatography with fluorimetric detection.

    Science.gov (United States)

    Viñas, Pilar; Bravo-Bravo, María; López-García, Ignacio; Hernández-Córdoba, Manuel

    2013-01-15

    This study describes a method for coupling dispersive liquid-liquid microextraction (DLLME) and normal-phase liquid chromatography (NP-LC) with fluorescence detection for vitamin A determination with the view to developing a new green sample preparation technique. Parameters affecting DLLME, including the nature and volume of both extractant and disperser solvents, salt addition and time and speed of the centrifugation step, were optimized. The sample was saponified according to European Standards to convert all forms of vitamin A to retinol. For microextraction, 8 mL water were placed in a glass tube with conical bottom and the saponified sample consisting of 2 mL of the methanolic extract containing 100 μL tetrachloroethane was rapidly injected by syringe, thereby forming a cloudy solution. Phase separation was performed by centrifugation, and a volume of 20 μL of the sedimented phase was analyzed by NP-LC. The enrichment factor, calculated as the ratio between the slopes of DLLME-LC and direct LC, was 50 ± 3. The matrix effect was evaluated for different juice samples, and it was concluded that sample quantification can be carried out by aqueous calibration when the standards are also submitted to saponification. The proposed method was applied for determining both cis- and trans-retinol isomers in commercial juices of different types. The intraday and interday precisions were lower than 6% in terms of relative standard deviation. The method was validated using two certified reference materials. Copyright © 2012 Elsevier B.V. All rights reserved.

  10. Evaluation of the thermal performance with different fin shapes of the air-cooled heat sink for power electronic applications

    Directory of Open Access Journals (Sweden)

    Chang-Woo Han

    2016-01-01

    Full Text Available The proper selection of the heat sink, which is attached at the insulated-gate bipolar transistor (IGBT module to dissipate heat by electric losses of the IGBT/diode chips, is important to satisfy the design criterion of the IGBT module. Prior to the performance evaluation of the air-cooled heat sink using the numerical method, the suitability of the simulation model was validated through the experimental result of the developed product. The simulation model predicted the hotspot temperature on the heat sink within a margin of error of 5.6 percent. From the verified numerical method, the thermal performance of the heat sink was evaluated according to the shape of the fins. The heat sink with the perforated fins had an excellent thermal performance because the rate of increment of the dissipation area was greater than the rate of decrement of the convection coefficient. The selected heat sink with the perforated fins was attached at the IGBT module and the junction temperature of the IGBT module was predicted. The predicted junction temperature was 131.4°C and the result satisfied the design criterion of 140.0°C.

  11. Evaluation of cool season precipitation event characteristics over the Northeast US in a suite of downscaled climate model hindcasts

    Science.gov (United States)

    Loikith, Paul C.; Waliser, Duane E.; Kim, Jinwon; Ferraro, Robert

    2017-08-01

    Cool season precipitation event characteristics are evaluated across a suite of downscaled climate models over the northeastern US. Downscaled hindcast simulations are produced by dynamically downscaling the Modern-Era Retrospective Analysis for Research and Applications version 2 (MERRA2) using the National Aeronautics and Space Administration (NASA)-Unified Weather Research and Forecasting (WRF) regional climate model (RCM) and the Goddard Earth Observing System Model, Version 5 (GEOS-5) global climate model. NU-WRF RCM simulations are produced at 24, 12, and 4-km horizontal resolutions using a range of spectral nudging schemes while the MERRA2 global downscaled run is provided at 12.5-km. All model runs are evaluated using four metrics designed to capture key features of precipitation events: event frequency, event intensity, even total, and event duration. Overall, the downscaling approaches result in a reasonable representation of many of the key features of precipitation events over the region, however considerable biases exist in the magnitude of each metric. Based on this evaluation there is no clear indication that higher resolution simulations result in more realistic results in general, however many small-scale features such as orographic enhancement of precipitation are only captured at higher resolutions suggesting some added value over coarser resolution. While the differences between simulations produced using nudging and no nudging are small, there is some improvement in model fidelity when nudging is introduced, especially at a cutoff wavelength of 600 km compared to 2000 km. Based on the results of this evaluation, dynamical regional downscaling using NU-WRF results in a more realistic representation of precipitation event climatology than the global downscaling of MERRA2 using GEOS-5.

  12. Solar radiation and cooling load calculation for radiant systems: Definition and evaluation of the Direct Solar Load

    DEFF Research Database (Denmark)

    Causone, Francesco; Corgnati, Stefano P.; Filippi, Marco

    2010-01-01

    The study of the influence of solar radiation on the built environment is a basic issue in building physics and currently it is extremely important because glazed envelopes are widely used in contemporary architecture. In the present study, the removal of solar heat gains by radiant cooling systems...... is investigated. Particular attention is given to the portion of solar radiation converted to cooling load, without taking part in thermal absorption phenomena due to the thermal mass of the room. This specific component of the cooling load is defined as the Direct Solar Load. A simplified procedure to correctly...... calculate the magnitude of the Direct Solar Load in cooling load calculations is proposed and it is implemented with the Heat Balance method and the Radiant Time Series method. The F ratio of the solar heat gains directly converted to cooling load, in the case of a low thermal mass radiant ceiling...

  13. Information technology equipment cooling method

    Science.gov (United States)

    Schultz, Mark D.

    2015-10-20

    According to one embodiment, a system for removing heat from a rack of information technology equipment may include a sidecar indoor air to liquid heat exchanger that cools air utilized by the rack of information technology equipment to cool the rack of information technology equipment. The system may also include a liquid to liquid heat exchanger and an outdoor heat exchanger. The system may further include configurable pathways to connect and control fluid flow through the sidecar heat exchanger, the liquid to liquid heat exchanger, the rack of information technology equipment, and the outdoor heat exchanger based upon ambient temperature and/or ambient humidity to remove heat generated by the rack of information technology equipment.

  14. Evaluation of five procedures for measuring nonstandard doses of nifedipine liquid.

    Science.gov (United States)

    Rosen, W J; Johnson, C E

    1989-11-01

    Five methods for removing the maximum volume of liquid from a nifedipine capsule were evaluated for efficiency and reproducibility, and the concentration of nifedipine in Procardia and Adalat 10- and 20-mg capsules was determined The methods evaluated were the needle puncture and squeeze method; the scissors method; the needle and syringe, one-hole method; the needle and syringe, two-hole method; and the capsule in syringe barrel method. The liquid content of 10 Adalat 10-mg capsules was removed by each method, the volume was determined by the weight and specific gravity of the nifedipine liquid, and the mean volumes of nifedipine liquid were compared. A stepwise procedure for using the needle and syringe, one-hole method was developed. The mean nifedipine concentration in Procardia 10- and 20-mg capsules was determined by ultraviolet spectrophotometry by using 30 capsules of each brand and strength. The needle and syringe methods were the most reproducible and efficient procedures for obtaining a desired milligram dosage of nifedipine from the capsules. The two-hole method would be less practical in the clinical setting, however, because it is time consuming and cumbersome. The mean assayed nifedipine concentration in the Procardia and Adalat 10- and 20-mg capsules was within 10% of the concentration reported by the manufacturer for each specific product lot number. Based on reproducibility and efficiency, the needle and syringe methods are the best methods for quantitation of liquid nifedipine doses for patient administration.

  15. An energetic evaluation of dissolution corrosion capabilities of liquid metals on iron surface.

    Science.gov (United States)

    Xu, Yichun; Song, Chi; Zhang, Yange; Liu, C S; Pan, B C; Wang, Zhiguang

    2014-08-21

    Using first principles calculations, dissolution corrosion of liquid metals on iron surfaces has been investigated by calculating adsorption energies of metal atoms in the liquid phase on the surface and escape energies of surface Fe atoms. The adsorption energies, characterizing the stability of the adsorbed atoms on the investigated surfaces, show that Bi is more stable than Pb and Au. The escape energies, representing the energy required for an Fe atom to escape from the surface, show that adsorbed Pb makes surface Fe atoms escape more easily than Bi and Au. The combination of adsorption energy and escape energy indicates that the corrosion capabilities of liquid metals decrease in the order Bi > Pb > Au. This is further proved by the investigation of surface properties, such as inter-layer distance, magnetic momentum and charge density difference. The results are consistent with experimental results that Fe can be corroded more severely in Bi than in Pb. In the case of liquid alloys, chemical proportions of compositions are incorporated to evaluate the corrosion capabilities of Pb-Bi eutectic (LBE) and Pb-Au eutectic (LGE). It is found that LBE has more severe corrosion capability than LGE. The energetic calculation is further developed in evaluating the effect of alloying elements in popular steels on the dissolution corrosion. The results indicate that Si, V, Nb and Mo may mitigate the dissolution corrosion of martensite steels in liquid Pb, Bi and Au.

  16. Principal components analysis for quality evaluation of cooled banana 'Nanicão' in different packing

    Directory of Open Access Journals (Sweden)

    Sanches Juliana

    2003-01-01

    Full Text Available This work aims determinate the evaluation of the quality of 'Nanicão' banana, submitted to two conditions of storage temperature and three different kinds of package, using the technique of the Analysis of Principal Components (ACP, as a basis for an Analysis of Variance. The fruits used were 'Nanicão' bananas, at ripening degree 3, that is, more green than yellow. The packages tested were: "Torito" wood boxes, load capacity: 18 kg; "½ box" wood boxes, load capacity: 13 kg; and cardboard boxes, load capacity: 18 kg. The temperatures assessed were: room temperature (control; and (13±1ºC, with humidity controlled to 90±2,5%. Fruits were discarded when a sensory analysis determined they had become unfit for consumption. Peel coloration, percentages of imperfection, fresh mass, total acidity, pH, total soluble solids and percentages of sucrose were assessed. A completely randomized design with a 2-factorial treatment structure (packing X temperature was used. The obtained data were analyzed through a multivariate analysis known as Principal Components Analysis, using S-plus 4.2. The conclusion was that the best packages to preserve the fruit were the ½ box ones, which proves that it is necessary to reduce the number of fruits per package to allow better ventilation and decreases mechanical injuries and ensure quality for more time.

  17. Evaluated kinetic and photochemical data for atmospheric chemistry: Volume VI – heterogeneous reactions with liquid substrates

    Directory of Open Access Journals (Sweden)

    M. Ammann

    2013-08-01

    Full Text Available This article, the sixth in the ACP journal series, presents data evaluated by the IUPAC Task Group on Atmospheric Chemical Kinetic Data Evaluation. It covers the heterogeneous processes involving liquid particles present in the atmosphere with an emphasis on those relevant for the upper troposphere/lower stratosphere and the marine boundary layer, for which uptake coefficients and adsorption parameters have been presented on the IUPAC website since 2009. The article consists of an introduction and guide to the evaluation, giving a unifying framework for parameterisation of atmospheric heterogeneous processes. We provide summary sheets containing the recommended uptake parameters for the evaluated processes. The experimental data on which the recommendations are based are provided in data sheets in separate appendices for the four surfaces considered: liquid water, deliquesced halide salts, other aqueous electrolytes and sulfuric acid.

  18. Thermal Predictions of the Cooling of Waste Glass Canisters

    Energy Technology Data Exchange (ETDEWEB)

    Donna Post Guillen

    2014-11-01

    Radioactive liquid waste from five decades of weapons production is slated for vitrification at the Hanford site. The waste will be mixed with glass forming additives and heated to a high temperature, then poured into canisters within a pour cave where the glass will cool and solidify into a stable waste form for disposal. Computer simulations were performed to predict the heat rejected from the canisters and the temperatures within the glass during cooling. Four different waste glass compositions with different thermophysical properties were evaluated. Canister centerline temperatures and the total amount of heat transfer from the canisters to the surrounding air are reported.

  19. Passive Two-Phase Cooling of Automotive Power Electronics: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Moreno, G.; Jeffers, J. R.; Narumanchi, S.; Bennion, K.

    2014-08-01

    Experiments were conducted to evaluate the use of a passive two-phase cooling strategy as a means of cooling automotive power electronics. The proposed cooling approach utilizes an indirect cooling configuration to alleviate some reliability concerns and to allow the use of conventional power modules. An inverter-scale proof-of-concept cooling system was fabricated, and tests were conducted using the refrigerants hydrofluoroolefin HFO-1234yf and hydrofluorocarbon HFC-245fa. Results demonstrated that the system can dissipate at least 3.5 kW of heat with 250 cm3 of HFC-245fa. An advanced evaporator design that incorporates features to improve performance and reduce size was conceived. Simulation results indicate its thermal resistance can be 37% to 48% lower than automotive dual side cooled power modules. Tests were also conducted to measure the thermal performance of two air-cooled condensers--plain and rifled finned tube designs. The results combined with some analysis were then used to estimate the required condenser size per operating conditions and maximum allowable system (i.e., vapor and liquid) temperatures.

  20. ICPP radioactive liquid and calcine waste technologies evaluation final report and recommendation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-04-01

    Using a formalized Systems Engineering approach, the Latched Idaho Technologies Company developed and evaluated numerous alternatives for treating, immobilizing, and disposing of radioactive liquid and calcine wastes at the Idaho Chemical Processing Plant. Based on technical analysis data as of March, 1995, it is recommended that the Department of Energy consider a phased processing approach -- utilizing Radionuclide Partitioning for radioactive liquid and calcine waste treatment, FUETAP Grout for low-activity waste immobilization, and Glass (Vitrification) for high-activity waste immobilization -- as the preferred treatment and immobilization alternative.

  1. Utilization of municipal wastewater for cooling in thermoelectric power plants: Evaluation of the combined cost of makeup water treatment and increased condenser fouling

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Michael E. [Illinois Inst. of Technology, Chicago, IL (United States). Dept. of Chemical and Biological Engineering; Theregowda, Ranjani B. [Carnegie Mellon Univ., Pittsburgh, PA (United States). Dept of Civil and Mechanical Engineering; Safari, Iman [Illinois Inst. of Technology, Chicago, IL (United States). Dept. of Chemical and Biological Engineering; Abbasian, Javad [Illinois Inst. of Technology, Chicago, IL (United States). Dept. of Chemical and Biological Engineering; Arastoopour, Hamid [Illinois Inst. of Technology, Chicago, IL (United States). Dept. of Chemical and Biological Engineering; Dzombak, David A. [Carnegie Mellon Univ., Pittsburgh, PA (United States). Dept of Civil and Mechanical Engineering; Hsieh, Ming-Kai [Tamkang Univ., Taipei (Taiwan). Waer Resources Management and Policy Research Center; Miller, David C. [National Energy Technology Lab. (NETL), Morgantown, WV (United States)

    2013-10-01

    A methodology is presented to calculate the total combined cost (TCC) of water sourcing, water treatment and condenser fouling in the recirculating cooling systems of thermoelectric power plants. The methodology is employed to evaluate the economic viability of using treated municipal wastewater (MWW) to replace the use of freshwater as makeup water to power plant cooling systems. Cost analyses are presented for a reference power plant and five different tertiary treatment scenarios to reduce the scaling tendencies of MWW. Results indicate that a 550 MW sub-critical coal fired power plant with a makeup water requirement of 29.3 ML/day has a TCC of $3.0 - 3.2 million/yr associated with the use of treated MWW for cooling. (All costs USD 2009). This translates to a freshwater conservation cost of $0.29/kL, which is considerably lower than that of dry air cooling technology, $1.5/kL, as well as the 2020 conservation cost target set by the U.S. Department of Energy, $0.74/kL. Results also show that if the available price of freshwater exceeds that of secondary-treated MWW by more than $0.13-0.14/kL, it can be economically advantageous to purchase secondary MWW and treat it for utilization in the recirculating cooling system of a thermoelectric power plant.

  2. Evaluation of radiation heat transfer in porous medial: Application for a pebble bed modular reactor cooled by CO2 gas

    Directory of Open Access Journals (Sweden)

    Sidi-Ali Kamel

    2013-01-01

    Full Text Available This work analyses the contribution of radiation heat transfer in the cooling of a pebble bed modular reactor. The mathematical model, developed for a porous medium, is based on a set of equations applied to an annular geometry. Previous major works dealing with the subject have considered the forced convection mode and often did not take into account the radiation heat transfer. In this work, only free convection and radiation heat transfer are considered. This can occur during the removal of residual heat after shutdown or during an emergency situation. In order to derive the governing equations of radiation heat transfer, a steady-state in an isotropic and emissive porous medium (CO2 is considered. The obtained system of equations is written in a dimensionless form and then solved. In order to evaluate the effect of radiation heat transfer on the total heat removed, an analytical method for solving the system of equations is used. The results allow quantifying both radiation and free convection heat transfer. For the studied situation, they show that, in a pebble bed modular reactor, more than 70% of heat is removed by radiation heat transfer when CO2 is used as the coolant gas.

  3. Isolation of a sulfide-producing bacterial consortium from cooling-tower water: Evaluation of corrosive effects on galvanized steel.

    Science.gov (United States)

    Ilhan-Sungur, Esra; Ozuolmez, Derya; Çotuk, Ayşın; Cansever, Nurhan; Muyzer, Gerard

    2017-02-01

    Sulfidogenic Clostridia and sulfate reducing bacteria (SRB) often cohabit in nature. The presence of these microorganisms can cause microbially influenced corrosion (MIC) of materials in different ways. To investigate this aspect, bacteria were isolated from cooling tower water and used in corrosion tests of galvanized steel. The identity of the isolates was determined by comparative sequence analysis of PCR-amplified 16S rDNA gene fragments, separated by denaturing gradient gel electrophoresis (DGGE). This analysis showed that, in spite of the isolation process, colonies were not pure and consisted of a mixture of bacteria affiliated with Desulfosporosinus meridiei and Clostridium sp. To evaluate the corrosive effect, galvanized steel coupons were incubated with a mixed culture for 4, 8, 24, 72, 96, 168, 360 and 744 h, along with a control set in sterile culture medium only. The corrosion rate was determined by weight loss, and biofilm formation and corroded surfaces were observed by scanning electron microscopy (SEM). Although the sulfide-producing bacterial consortium led to a slight increase in the corrosion of galvanized steel coupons, when compared to the previous studies it can be said that Clostridium sp. can reduce the corrosive effect of the Desulfosporosinus sp. strain. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. Advanced gas cooled nuclear reactor materials evaluation and development program. Selection of candidate alloys. Vol. 1. Advanced gas cooled reactor systems definition

    Energy Technology Data Exchange (ETDEWEB)

    Marvin, M.D.

    1978-10-31

    Candidate alloys for a Very High Temperature Reactor (VHTR) Nuclear Process Heal (NPH) and Direct Cycle Helium Turbine (DCHT) applications in terms of the effect of the primary coolant exposure and thermal exposure were evaluated. (FS)

  5. Intake and physiological response of Jersey cows to cooling ...

    African Journals Online (AJOL)

    In order to evaluate the response of Jersey cows to cooling measures in a hot environment, four cows were subjected to four cooling treatments using a Latin square design. Treatments consists of control (access to shade without extra cooling), cooling with fan, cooling with shower, cooling with fan and shower. Animals ...

  6. Treatment option evaluation for liquid effluent secondary streams on the Hanford Site

    Energy Technology Data Exchange (ETDEWEB)

    Holter, G.M.; Triplett, M.B.; Fow, C.L.; White, M.K.

    1988-08-01

    This study, conducted by the Pacific Northwest Laboratory (PNL) for Westinghouse Hanford Company (WHC), examines the range of secondary waste types and volumes likely to result from treatment of contaminated liquid effluents. Alternatives for treatment of these effluents were considered, taking into account the implementation of the ''best-available technology'' as assumed in current and ongoing engineering studies for treating the various liquid effluent waste streams. These treatment alternatives, and potential variations in the operating schedules for Hanford Site facilities generating contaminated liquid effluents, were evaluated to project an estimated range for the volume of each of the various secondary waste streams that are likely to be generated. The conclusions and recommendations were developed, based on these estimates. 23 refs., 34 figs., 16 tabs.

  7. Theoretical investigations on improving performance of cooling systems for fuel cell vehicles; Theoretische Untersuchungen zur Kuehlleistungssteigerung durch innovative Kuehlsysteme fuer Brennstoffzellen-Elektrofahrzeuge

    Energy Technology Data Exchange (ETDEWEB)

    Reichler, Mark

    2008-04-01

    In this work theoretical investigations are carried out for cooling systems, which are used in fuel cell vehicles. This work focuses mainly on the capability of increasing the heat rejection rate by using new alternative cooling systems and by improving the conventional cooling system. Fuel cell vehicles have a higher demand of heat rejection to the ambient than comparable vehicles with combustion engine. The performance of conventional liquid cooling systems, especially at high loads and high ambient temperatures, is often not sufficient anymore. Hence, cooling systems with improved performance are necessary for fuel cell vehicles. The investigations in this work are based on DaimlerChrysler's ''A-Class'' having a PEM-Fuel Cell system integrated. Specific computational models are developed for radiators and condensers to evaluate the performance of different cooling concepts. The models are validated with experimental data. Based on an intensive investigation in the open literature the state of the art of cooling systems for fuel cell vehicles is depicted. Furthermore new cooling concepts as an alternative to the liquid cooling system are presented. The method of cooling the fuel cell by using two-phase transition shows the greatest capability to increase the cooling performance. Hence, this concept is investigated in detail. Two different concepts with three different refrigerants (R113, R245fa und R236fa) are analyzed. Cooling performance of this concept shows improvement of 18.2 up to 32.6 % compared to the conventional liquid cooling system. Thus, a two phase cooling system represents an alternative cooling system for fuel cell vehicles, which should be closer investigated by experiments. (orig.)

  8. CO$_2$ cooling experience (LHCb)

    CERN Document Server

    Van Lysebetten, Ann; Verlaat, Bart

    2007-01-01

    The thermal control system of the LHCb VErtex LOcator (VELO) is a two-phase C0$_2$ cooling system based on the 2-Phase Accumulator Controlled Loop (2PACL) method. Liquid carbon dioxide is mechanically pumped in a closed loop, chilled by a water-cooled freon chiller and evaporated in the VELO detector. The main goal of the system is the permanent cooling of the VELO silicon sensors and of the heat producing front-end electronics inside a vacuum environment. This paper describes the design and the performance of the system. First results obtained during commissioning are also presented.

  9. Graphite-modified cooling ceiling. A comparative evaluation of the performance; Graphitmodifizierte Kuehldecken. Eine vergleichende Bewertung zur Leistungsfaehigkeit

    Energy Technology Data Exchange (ETDEWEB)

    Hauser, Gerd [Technische Univ. Muenchen (Germany); Fraunhofer-Institut fuer Bauphysik, Stuttgart (Germany); Hausladen, Gerhard [Technische Univ. Muenchen (Germany); Ingenieurbuero Hausladen GmbH, Muenchen (Germany); Jacobsen, Cornelia; Hutter, Christina; Hanusch, Christoph [Ingenieurbuero Hausladen GmbH, Muenchen (Germany); Schlitzberger, Stephan [Ingenieurbuero fuer Bauphysik Prof. Dr. Hauser GmbH, Kassel (Germany)

    2013-03-01

    In most cases, the utilization of graphite-modified building materials enhances their thermal conductivity. Thus, chilled ceiling systems achieve an enhanced thermal absorption in comparison to commercial chilled ceiling systems. For this, a simulation for the estimation of the thermal comfort as well as for the quantification of the impacts on the demand of electricity for the refrigeration is performed. The enhanced cooling capacity of the graphite-modified cooling ceiling 'Ecophit' affects the operation positively.

  10. Utilizing of inner porous structure in injection moulds for application of special cooling method

    Science.gov (United States)

    Seidl, M.; Bobek, J.; Šafka, J.; Habr, J.; Nováková, I.; Běhálek, L.

    2016-04-01

    The article is focused on impact evaluation of controlled inner structure of production tools and new cooling method on regulation of thermal processes for injection moulding technology. The mould inserts with porous structure were cooled by means of liquid CO2 which is very progressive cooling method and enables very fast and intensive heat transfer among the plastic product, the production tool and cooling medium. The inserts were created using rapid prototype technology (DLSM) and they had a bi-component structure consisting of thin compact surface layer and defined porous inner structure of open cell character where liquid CO2 was flowing through. This analyse includes the evaluation of cooling efficiency for different inner structures and different time profiles for dosing of liquid CO2 into the porous structure. The thermal processes were monitored using thermocouples and IR thermal analyse of product surface and experimental device. Intensive heat removal influenced also the final structure and the shape and dimensional accuracy of the moulded parts that were made of semi-crystalline polymer. The range of final impacts of using intensive cooling method on the plastic parts was defined by DSC and dimensional analyses.

  11. DESIGN OF A SIMPLE SLOW COOLING DEVICE FOR CRYOPRESERVATION OF SMALL BIOLOGICAL SAMPLES.

    Science.gov (United States)

    de Paz, Leonardo Juan; Robert, Maria Celeste; Graf, Daniel Adolfo; Guibert, Edgardo Elvio; Rodriguez, Joaquin Valentin

    2015-01-01

    Slow cooling is a cryopreservation methodology where samples are cooled to its storage temperature at controlled cooling rates. Design, construction and evaluation of a simple and low cost device for slow cooling of small biological samples. The device was constructed based on Pye's freezer idea. A Dewar flask filled with liquid nitrogen was used as heat sink and a methanol bath containing the sample was cooled at constant rates using copper bars as heat conductor. Sample temperature may be lowered at controlled cooling rate (ranging from 0.4°C/min to 6.0°C/min) down to ~-60°C, where it could be conserved at lower temperatures. An example involving the cryopreservation of Neuro-2A cell line showed a marked influence of cooling rate over post preservation cell viability with optimal values between 2.6 and 4.6°C/min. The cooling device proved to be a valuable alternative to more expensive systems allowing the assessment of different cooling rates to evaluate the optimal condition for cryopreservation of such samples.

  12. Reducing the Liquid Helium Consumption of Superconducting Rock Magnetometers (SRMs) used in Paleomagnetic and Rock Magnetic studies: Gallium Lubrication of Gifford-McMahon Cryocoolers Leads to a Dramatic Increase in Cool-down Efficiency, and a Drop in Liquid Helium Consumption

    Science.gov (United States)

    Kirschvink, J. L.

    2015-12-01

    Two-stage Gifford-McMahon helium-gas cryocoolers have been used for the past 40+ years in a wide variety of cryogenic applications, including reducing the liquid helium consumption of SRMs. However, the cooling efficiency depends greatly on the friction of the displacement pistons, which need to be replaced every few years. This and the rising cost of liquid helium are major headaches in the operation of modern paleomagnetic laboratories. Although the development of efficient pulse-tube cryocoolers has eliminated the need for liquid helium in new superconducting magnetometers, there are still nearly 100 older SRMs around the globe that use liquid helium. In a failed attempt to replace the Gifford-McMahon unit on one of Caltech's SRMs with a pulse-tube, we irreversibly contaminated the cylindrical surfaces of the stainless-steel heat exchanger with a thin film of gallium, a non-toxic metal that has a melting temperature of ~ 30˚C. Liquid gallium will diffuse into other metals, altering their surface properties. We noticed that the next cryocooler-assisted cool down of the SRM went nearly twice as fast as in previous cycles, and the helium boiloff rate for the past 2 years has stabilized at less than half of its average over the past 30 years. It seems that the thin layer of gallium may be reducing the sliding friction of the Gifford-McMahon cryocoolers. We recently tested this on a second SRM, with similar results. We found that the inner cryocooler surface reached its equilibrium temperature in about 1/3 of the time that it took in previous cool-down cycles. WSGI also confirmed that this cool-down was unusually efficient compared to other instruments they have built. Subsequent records of the helium gas boiloff show that this system is also running at about half of its former loss rate. Based on these two results, we tentatively recommend this simple procedure any time cold-head swaps are performed on these cryocoolers.

  13. Evaluation of silicon, calcium and magnesium in liquid fertilizers on sorghum growth in the greenhouse

    Directory of Open Access Journals (Sweden)

    Mario A. Araya

    2015-11-01

    Full Text Available The effect of liquid fertilizers with Si, Ca or Mg on the growth of sorghum (Sorghum bicolor was evaluated in an Ultisol under greenhouse conditions. Four liquid fertilizers (two potassium silicates, calcium carbonate and magnesium oxide were applied into the soil in liquids at doses of 2 and 4 ml.pot-1, plus a control, in a randomized unrestricted design with 9 treatments and 4 replicates. Growth variables, assessed 45 days after sowing, were dry weight of root and aerial parts. Analysis of soil and plant at the end of the test was performed. The application of Ca and Mg significantly increased growth and nutrient uptake of sorghum. Liquid calcium carbonate promoted the highest values of dry biomass and absorption of N, P, Ca, S, Cu, Zn, Mn and B. Si sources had no significant effects on biomass, except for K silicate with Ca and Mg at the dose of 4 ml.pot-1, which also produced a significant increase in K absorption. Calcium carbonate and magnesium oxide significantly increased soil pH and decreased exchangeable acidity and Al, and also increased Ca or Mg content in the soil.

  14. [Evaluation of genotyping of human papilomavirus by a new DNA liquid chip based on Luminex XMAP].

    Science.gov (United States)

    Deng, Xiao-mei; Liu, Min; Zheng, Gui-xi; Wang, Chuan-xin; Zhang, Jian; Li, Wei

    2009-12-01

    To evaluate the diagnostic value of Luminex XMAP liquid chip for HPV detection. Detect HPV DNA with the liquid chip and HC II in 264 cases, including 231 of cervical cancer and 33 of cervical scrapes. The accordance of two methods were compared and DNA sequencing was performed in conflicting samples and single (infection samples. There is an excellent agreement between the methods. The overall incidence of HPV was 82.95%, the most common genotypes were HPV 16, 52, 58, 18, 11, 31, 6, 39, 33, 56, 70. Among all the positive types, 117 were single type and 102 were multiple types, and 87.43% were high-risk HPV genotypes and 12.57% were low-risk genotypes. Based on the criteria of histology and pathology, the sensitivity, specificity, positive and negative-predictive value of HPV liquid chip and HC II for detecting all cases of CIN II, III and carcinomas were respectively 93.07%, 87.88%, 98.17%, 64.44% and 94.81%, 87.88%, 98.21%, 70.73%. The common types of HPV infection are 16, 52, 58, 18, 11, 6, 56 and 31. Multiplex HPV genotyping by Luminex XMAP liquid chip appears to be highly suitable for diagnostic screening and large-scale epidemiological studies.

  15. Engineering evaluation of alternatives: Technologies for monitoring interstitial liquids in single-shell tanks

    Energy Technology Data Exchange (ETDEWEB)

    Brevick, C.H. [ICF Kaiser Hanford Co., Richland, WA (United States); Jenkins, C.E. [Westinghouse Hanford Co., Richland, WA (United States)

    1996-02-01

    A global search of mature, emerging, and conceptual tank liquid monitoring technologies, along with a historical review of Hanford tank farm waste monitoring instrumentation, was conducted to identify methods for gauging the quantity of interstitial waste liquids contained in Hanford SSTs. Upon completion of the search, an initial screening of alternatives was conducted to identify candidates which might be capable of monitoring interstitial tank liquids. The nine candidate technologies that were selected, evaluated, and ranked are summarized. Hydrostatic tank gauging (HTG) is the technology generally recommended for gauging the quantity of process materials contained in Hanford SSTs. HTG is a mass-based technique that has the capability for continuous remote monitoring. HTG has the advantages of no moving parts, intrinsic safety, and potentially gauging a one-million gal tank with a precision of approximately {+-}500 pounds (i.e., {+-}62 gal of water or {+-}0.02 in. of level in a 75 ft diameter tank). HTG is relatively inexpensive and probe design, construction, testing, installation, and operation should be straightforward. HTG should be configured as part of a hybrid tank gauging system. A hybrid system employs two or more independent measurement systems which function in concert to provide redundancy, improved accuracy, and maximum information at minimum cost. An excellent hybrid system choice for monitoring interstitial liquids in SSTs might be the combination of HTG with thermal differential technology.

  16. Study of evaluation methods for in-vessel corium retention through external vessel cooling and safety of reactor cavity

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Hoon; Chang, Soon Heung; Kim, Soo Hyung; Kim, Kee Poong; Lee, Hyoung Wook; Jang, Kwang Keol; Jeong, Yong Hoon; Kim, Sang Jin; Lee, Seong Jin [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of); Park, Jae Hong [Korea Institute of Nuclear Safety, Taejon (Korea, Republic of)

    2001-03-15

    In this work, assessment system for methodology for reactor pressure vessel integrity is developed. Assessment system is make up of severe accident assessment code which can calculate the conditions of plant and structural analysis code which can assess the integrity of reactor vessel using given plant conditions. An assessment of cavity flooding using containment spray system has been done. As a result, by the containment spray, cavity can be flooded successfully and CCI can be reduced. The technical backgrounds for external vessel cooling and corium cooling on the cavity are summarized and provided in this report.

  17. Quality evaluation of extemporaneous delayed-release liquid formulations of lansoprazole.

    Science.gov (United States)

    Melkoumov, Alexandre; Soukrati, Amina; Elkin, Igor; Forest, Jean-Marc; Hildgen, Patrice; Leclair, Grégoire

    2011-11-01

    The quality attributes of extemporaneous delayed-release liquid formulations of lansoprazole for oral administration were evaluated. A novel liquid formulation (3 mg/mL) of Prevacid FasTab in an Ora-Blend vehicle was prepared and compared with the Prevacid FasTab 30 mg and Prevacid-sodium bicarbonate 1 M formulation (3 mg/mL). The latter formulation was combined with hydrochloric acid 0.1 N, and the remaining lansoprazole content was assayed by high-performance liquid chromatography (HPLC). A batch of delayed-release liquid formulation was prepared to evaluate content uniformity. For content assay, three samples were prepared for each evaluated condition and each sample was analyzed in triplicate by HPLC. The lansoprazole in the sodium bicarbonate formulation was extensively degraded by quantities of hydrochloric acid 0.1 N in excess of 100 mL. Storage time and temperature had a significant effect on lansoprazole stability in the Ora-Blend formulation. The drug remained stable for seven days when the formulation was stored at 4.5-5.5 °C, but storage at 21-22 °C or the reduction of pH with citric acid accelerated lansoprazole degradation. The amount of lansoprazole released from the Ora-Blend formulation during the buffer stage of the dissolution test decreased with increases in formulation storage time, in formulation storage temperature, and in the amount of lansoprazole released and degraded during the acid stage of the test. An extemporaneous formulation consisting of lansoprazole microgranules in Ora-Blend maintained acceptable quality attributes when stored for three days at 4.5-5.5 °C.

  18. Evaluation of Open Cell Foam Heat Transfer Enhancement for Liquid Rocket Engine

    Science.gov (United States)

    Chung, J. N.; Tully, Landon; Kim, Jung Hwan; Jones, Gregg W.; Watkins, William

    2006-01-01

    As NASA pursues the exploration mission, advanced propulsion for the next generation of spacecraft will be needed. These new propulsion systems will require higher performance and increased durability, despite current limitations on materials. A break-through technology is needed in the thrust chamber. In this paper the idea of using a porous metallic foam is examined for its potential cooling enhancement capabilities. The goal is to increase the chamber wall cooling without creating an additional pressure drop penalty. A feasibility study based on experiments at laboratory-scale conditions was performed and analysis at rocket conditions is underway. In the experiment, heat transfer and pressure drop data were collected using air as the coolant in a copper or nickel foam filled annular channel. The foam-channel performance was evaluated based on comparison with conventional microchannel cooling passages under equal pressure drop conditions. The heat transfer enhancement of the foam channel over the microchannel ranges from 130% to 172%. The enhancement is relatively independent of the pressure drop and increases with decreasing pore size. A direct numerical simulation model of the foam heat exchange has been built. The model is based on the actual metal foam microstructure of thin ligaments (0.2- 0.3 mm in diameter) that form a network of interconnected open-cells. The cell dimension is around 2 mm. The numerical model was built using the FLUENT CFD code. Comparison of the pressure drop results predicted by the current model with those experimental data of Leong and Jin [8] shows favorable comparisons. Pressure drop predictions have been made using hydrogen as a coolant at typical rocket conditions. Conjugate heat transfer analysis using the foam filled channel is planned for the future.

  19. Pharmacoeconomic evaluation of the costs incurred by the ASP Messina for home therapy with liquid oxygen

    Directory of Open Access Journals (Sweden)

    Salvatore Coppolino

    2010-03-01

    Full Text Available Chronic obstructive pulmonary disease (COPD is a very frequent disease in all industrialized countries. The cost for the community includes cost for hospitalisations, doctor visits, home care, rehabilitation, loss of working days, etc. From a therapeutical point of view, an effective progression of therapy and patients survival can be obtained only by stopping smoking and by following a long term oxygen therapy. The aim of this retrospective study is to evaluate costs of liquid oxygen therapy performed at home. Obtained results are very encouraging because a part from being cheap they also provide a better evaluation of the prescribed therapy which can also be extended to gaseous oxygen.

  20. Compact photomultiplier housing with controlled cooling.

    Science.gov (United States)

    SHARDANAND

    1972-01-01

    Description of a compact photomultiplier housing which can provide controlled cooling to the photomultiplier tube down to -90 C. The cooling is accomplished by flowing liquid nitrogen cooled helium gas through a series of coils which envelop the photocathode portion of the tube. The temperature is controlled by controlling the flow of the gas with a fine adjustable needle valve. The temperature is measured near the photocathode of the photomultiplier by a calibrated thermistor.

  1. A very cool cooling system

    CERN Multimedia

    Antonella Del Rosso

    2015-01-01

    The NA62 Gigatracker is a jewel of technology: its sensor, which delivers the time of the crossing particles with a precision of less than 200 picoseconds (better than similar LHC detectors), has a cooling system that might become the precursor to a completely new detector technique.   The 115 metre long vacuum tank of the NA62 experiment. The NA62 Gigatracker (GTK) is composed of a set of three innovative silicon pixel detectors, whose job is to measure the arrival time and the position of the incoming beam particles. Installed in the heart of the NA62 detector, the silicon sensors are cooled down (to about -20 degrees Celsius) by a microfluidic silicon device. “The cooling system is needed to remove the heat produced by the readout chips the silicon sensor is bonded to,” explains Alessandro Mapelli, microsystems engineer working in the Physics department. “For the NA62 Gigatracker we have designed a cooling plate on top of which both the silicon sensor and the...

  2. HYBRID COOLING SYSTEM FOR INDUSTRIAL APPLICATION

    African Journals Online (AJOL)

    ES Obe

    1980-03-01

    Mar 1, 1980 ... phase alone. The enhanced cooling rate yielded speed increase in production by about 65%. The system also reduced the level of noise due to air blast at the press by limiting the use of compressed air. This cooling unit could also be used in iron and steel industries. NOTATION m liquid-to-air mass flow ...

  3. Neutronic performance of two european breeder-inside tube (BIT) blankets for DEMO: Helium-cooled ceramic LiAlO{sub 2} with Be multiplier and water-cooled liquid Li17Pb 2103. international symposium on fusion nuclear technologies (ISFNT-3)

    Energy Technology Data Exchange (ETDEWEB)

    Petrizzi, L.; Rado, V. [Associazione EURATOM-ENEA sulla Fusione, Frascati (Italy)

    1994-11-01

    In support of ENEA (Italian Agency for New Technologies, Energy and the Environment) activity in the European Community Test Programme, a neutronic analysis has been performed on the two latest blanket design relative to helium-cooled ceramic BIT (breeder-inside-tube) (with LiAIO{sub 2} and Be multiplier) and the water-cooled liquid Li17Pb in cylindrical modules. At this scope the powerful MCNP Monte Carlo code has been used (version 4). A detailed and accurate description of the geometrical model has been performed inserting the main reactor details and avoiding breeder material dilution inside the modules. TBR performance is low for the solid breeder BIT (with 10 ports 1.011) due mainly to low blanket coverage near the exhaust duct and this solution should be revised. CM Li17Pb blanket reaches sufficient TBR (1.059, with ports) to rely on tritium self-sufficiency. Shielding properties, with respect to the toroidal field coils, have been estimated in a simplified model by means of the ANISN code, supplied with nuclear data library coherent with the one used by MCNP. The analysis suggests a careful shield thickness/composition design to be confident on the shielding capability of the whole blanket and shield system.

  4. Evaluation on the electrochemically deposited alkoxy thiourea as liquid crystalline semiconductor film

    Science.gov (United States)

    Rahamathullah, Rafizah; Khairul, Wan M.

    2017-12-01

    A new class of liquid crystalline film of alkoxy thiourea which was successfully deposited on indium tin oxide (ITO) coated substrate via electrochemical deposition method. The relationship between liquid crystal molecular structure, phase transition temperature and electrical performance was evaluated. The mesomorphic properties were identified via polarized optic microscopy (POM) which displayed cholesteric phase and their corresponding transition enthalpies were respectively recorded at 20.25 kJ mol-1. The findings from the conductivity analysis revealed that the fabricated film exhibits good electrical performance with an increasing conductivity up to 0.2170 S cm-1 under maximum light intensity of 100 W m-2. Therefore, this proposed type of molecular framework has given an ideal indication to act as semiconductor materials and has opened wide potential for application in organic electronic devices.

  5. Theory of tapered laser cooling

    Energy Technology Data Exchange (ETDEWEB)

    Okamoto, Hiromi; Wei, J.

    1998-03-25

    A theory of tapered laser cooling for fast circulating ion beams in a storage ring is constructed. The authors describe the fundamentals of this new cooling scheme, emphasizing that it might be the most promising way to beam crystallization. The cooling rates are analytically evaluated to study the ideal operating condition. They discuss the physical implication of the tapering factor of cooling laser, and show how to determine its optimum value. Molecular dynamics method is employed to demonstrate the validity of the present theory.

  6. Topical report: Natural convection shutdown heat removal test facility (NSTF) evaluation for generating additional reactor cavity cooling system (RCCS) data.

    Energy Technology Data Exchange (ETDEWEB)

    Farmer, M. T.; Kilsdonk, D. J.; Tzanos, C.P.; Lomperski, S.; Aeschlimann, R.W.; Pointer, D.; Nuclear Engineering Division

    2005-09-01

    As part of the Department of Energy (DOE) Generation IV roadmapping activity, the Very High Temperature gas cooled Reactor (VHTR) has been selected as the principal concept for hydrogen production and other process-heat applications such as district heating and potable water production. On this basis, the DOE has selected the VHTR for additional R&D with the ultimate goal of demonstrating emission-free electricity and hydrogen production with this advanced reactor concept. One of the key passive safety features of the VHTR is the potential for decay heat removal by natural circulation of air in a Reactor Cavity Cooling System (RCCS). The air-cooled RCCS concept is notably similar to the Reactor Vessel Auxiliary Cooling System (RVACS) that was developed for the General Electric PRISM sodium-cooled fast reactor. As part of the DOE R&D program that supported the development of this fast reactor concept, the Natural Convection Shutdown Heat Removal Test Facility (NSTF) was developed at ANL to provide proof-of-concept data for the RVACS under prototypic natural convection flow, temperature, and heat flux conditions. Due to the similarity between RVACS and the RCCS, current VHTR R&D plans call for the utilization of the NSTF to provide RCCS model development and validation data, in addition to supporting design validation and optimization activities. Both air-cooled and water-cooled RCCS designs are to be included. In support of this effort, ANL has been tasked with the development of an engineering plan for mechanical and instrumentation modifications to NSTF to ensure that sufficiently detailed temperature, heat flux, velocity and turbulence profiles are obtained to adequately qualify the codes under the expected range of air-cooled RCCS flow conditions. Next year, similar work will be carried out for the alternative option of a water-cooled RCCS design. Analysis activities carried out in support of this experiment planning task have shown that: (a) in the RCCS, strong

  7. Evaluation of the cool-down behaviour of ITER FW beryllium tiles for an early failure detection

    Directory of Open Access Journals (Sweden)

    Thomas Weber

    2016-12-01

    Full Text Available The design of the first wall in ITER foresees several hundred thousand beryllium tiles, which are bonded to the water-cooled CuCrZr supporting structure. Due to the nature of a Tokamak reactor this bonding is faced to thermal fatigue. Since the failure of a single tile might already have a major impact on the operability of ITER, comprehensive high heat flux tests are performed on prototypes prior to the acceptance of manufacturing procedures. For a deeper understanding of the temperature curves, which were and will be measured by IR devices of these first wall prototypes, thermo-mechanical FEM simulations shall demonstrate the possibilities of an early bonding failure detection. Hereby, the maximum temperatures for each cycle as well as the cool-down behaviour are the input data.

  8. Evaluation of dry feeding and liquid feeding to lactating sows under high temperature environment

    Directory of Open Access Journals (Sweden)

    J. S. Hong

    2016-10-01

    Full Text Available Abstract Background Liquid feeding system has been introduced to domestic swine farms, but negative cognition about liquid feeding system has been remained for feed waste decay related with poor management and microbial contamination. For these reasons, this study was conducted to evaluate the effects of feeding method in lactating sows. Methods A total of 30 mixed-parity (average 4.13 lactating sows (Yorkshire × Landrace with an initial BW of 218.8 ± 19.5kg was used in a 3 week trial. Sows were allotted to 1 of 2 treatments in a completely randomized design by their body weight, backfat thickness, parity and alive litter weight. One of treatments was dry feeding and the other was liquid feeding (water to feed ratio, 1:1. Experimental diets contained 3265 kcal ME/kg, 12.6 % CP, 5.76 % EE, 1.09 % total lysine, 0.25 % total methionine, as fed basis. Results Dry feeding treatment had high body weight loss rather than liquid feeding treatment (P = 0.04. Dry feeding treatment had tendency to increase litter weight at 21d of lactation (P = 0.06 and litter weight gain (P = 0.04 during lactation period (0–3 week. Sows fed dry feeding method made milk containing high content of casein and total solid rather than sows fed liquid feeding method (P = 0.04. In addition, dry feeding treatment had tendency to higher content of milk fat, protein and solid not fat on 21d of lactation (P = 0.07. Sows fed dry feeding type also showed higher milk energy content in milk of 21d lactation (P = 0.05. Furthermore, liquid feeding treatment showed high occurrence in feed waste during lactation period (P < 0.01. Conclusion Dry feeding method was more suitable feeding method to lactating sows under high temperature environment like lactating barn.

  9. JANNAF "Test and Evaluation Guidelines for Liquid Rocket Engines": Status and Application

    Science.gov (United States)

    Parkinson, Douglas; VanLerberghe, Wayne M.; Rahman, Shamim A.

    2017-01-01

    For many decades, the U.S. rocket propulsion industrial base has performed remarkably in developing complex liquid rocket engines that can propel critical payloads into service for the nation, as well as transport people and hardware for missions that open the frontiers of space exploration for humanity. This has been possible only at considerable expense given the lack of detailed guidance that captures the essence of successful practices and knowledge accumulated over five decades of liquid rocket engine development. In an effort to provide benchmarks and guidance for the next generation of rocket engineers, the Joint Army Navy NASA Air Force (JANNAF) Interagency Propulsion Committee published a liquid rocket engine (LRE) test and evaluation (T&E) guideline document in 2012 focusing on the development challenges and test verification considerations for liquid rocket engine systems. This document has been well received and applied by many current LRE developers as a benchmark and guidance tool, both for government-driven applications as well as for fully commercial ventures. The USAF Space and Missile Systems Center (SMC) has taken an additional near-term step and is directing activity to adapt and augment the content from the JANNAF LRE T&E guideline into a standard for potential application to future USAF requests for proposals for LRE development initiatives and launch vehicles for national security missions. A draft of this standard was already sent out for review and comment, and is intended to be formally approved and released towards the end of 2017. The acceptance and use of the LRE T&E guideline is possible through broad government and industry participation in the JANNAF liquid propulsion committee and associated panels. The sponsoring JANNAF community is expanding upon this initial baseline version and delving into further critical development aspects of liquid rocket propulsion testing at the integrated stage level as well as engine component level, in

  10. Cubic liquid crystalline nanoparticles: optimization and evaluation for ocular delivery of tropicamide.

    Science.gov (United States)

    Verma, Purnima; Ahuja, Munish

    2016-10-01

    The purpose of this study was to investigate the potential of cubic liquid crystalline nanoparticles for ocular delivery of tropicamide. Ultrasound-assisted fragmentation of cubic liquid crystalline bulk phases resulted in cubic liquid crystalline nanoparticles employing Pluronic F127 as dispersant. The effects of process variables such as sonication time, sonication amplitude, sonication depth, and pre-mixing time on particle size and polydispersity index was investigated using central composite design. The morphology of tropicamide-loaded nanoparticles was found to be nearly cubical in shape by transmission electron microscopy observation. Further, small angle X-ray scattering experiment confirmed the presence of D and P phase cubic structures in coexistence. The optimized tropicamide-loaded cubic nanoparticles showed in vitro corneal permeation of tropicamide across isolated porcine cornea comparable to its commercial preparation, Tropicacyl®. Ocular tolerance was evaluated by Hen's egg-chorioallantoic membrane test and histological studies. The results of in vivo mydriatic response study demonstrated a remarkably higher area under mydriatic response curve (AUC0→1440 min) values of cubic nanoparticles over Tropicacyl® indicating better therapeutic value of cubic nanoparticles. Furthermore, tropicamide-loaded cubic nanoparticles exhibited prolonged mydriatic effect on rabbits as compared to commercial conventional aqueous ophthalmic solution.

  11. REACTOR COOLING

    Science.gov (United States)

    Quackenbush, C.F.

    1959-09-29

    A nuclear reactor with provisions for selectively cooling the fuel elements is described. The reactor has a plurality of tubes extending throughout. Cylindrical fuel elements are disposed within the tubes and the coolant flows through the tubes and around the fuel elements. The fuel elements within the central portion of the reactor are provided with roughened surfaces of material. The fuel elements in the end portions of the tubes within the reactor are provlded with low conduction jackets and the fuel elements in the region between the central portion and the end portions are provided with smooth surfaces of high heat conduction material.

  12. Cool collapsible

    OpenAIRE

    Linnér, Fredrik

    2010-01-01

    Cool collabsible är ett projekt som har handlat om att skapa ett hopfällbart utomhusbord. Arbetet har utförts tillsammans med aka buna design consult. Projektet har fokuserats på att hitta en funktion, teknik och material för att sedan transformera detta till ett innovativt utomhusbord. Genom ett utförligt arbete med att definiera målgruppen skapades ramar som format ett bord till den typiska brukaren. Resultatet blev ett hopfällbart bord som hämtat sin inspiration från naturen. Ett bord som ...

  13. Calculation of liquid-cooled finplate tube heat exchangers for the dehumidification of air with an enhanced water load; Berechnung fluessigkeitsgekuehlter Lamellenrohr-Waermeuebertrager zur Entfeuchtung von Luft mit hoher Wasserbeladung

    Energy Technology Data Exchange (ETDEWEB)

    Sievers, Martin [Stuttgart Univ. (Germany). Inst. fuer Thermodynamik der Luft- und Raumfahrt; Sievers, Uwe [Hochschule fuer Angewandte Wissenschaften Hamburg (Germany). Inst. fuer Energiesysteme und Brennstoffzellentechnik

    2011-07-01

    Demoisturizing of air or combustion gases is a process step in many air conditioners, energy engineering plants and chemical plants, e.g. high-efficiency boilers, fuel cell systems, and sea water desalination systems. By cooling a gas-steam mixture down to below condensation temperature, the steam will be partly condensed, and the condensate will then be separated from the gaseous gas-steam mixture. Sea water desalination plants ave higher temperatures and higher air moisture at the demoisturizer inlet, so some of the common assumptions for calculation of combined heat and mass transfer are not applicable. The publication presents equations for calculating the demoisturizing of air with high water content, as in sea water desalination systems or fuel cell systems, for liquid-cooled finned-tube heat exchangers. The coupled heat and mass transfer is calculated without the common simplifying assumptions, and the calculation method based on the cell method is validated on the basis of measurements. [German] Die Entfeuchtung von Luft oder Verbrennungsgasen ist ein Prozessschritt, der in verschiedenen Anlagen der Klimatechnik, der Energietechnik und der Verfahrenstechnik auftritt. Beispiele sind Klimaanlagen in Gebaeuden und Fahrzeugen, Brennwertkessel, Brennstoffzellenanlagen und Meerwasserentsalzungsanlagen. In diesen wird durch Abkuehlung eines Gas-Dampf-Gemisches unter seine Taupunkttemperatur der Dampf teilweise kondensiert und anschliessend die Kondensatphase von dem gasfoermig verbleibenden Gas-Dampf-Gemisch abgetrennt. In Meerwasserentsalzungsanlagen zur Gewinnung von Trink- oder Brauchwasser, die nach dem Luftbefeuchtungs-Entfeuchtungs-(HDH)-Prinzip arbeiten, liegen die Temperatur und die Wasserbeladung der feuchten Luft am Eintritt in den Entfeuchter deutlich hoeher als in herkoemmlichen Klimaanlagen. Deshalb treffen hier einige uebliche vereinfachende Annahmen zur Berechnung des gekoppelten Waerme- und Stoffuebergangs nicht zu. Fuer fluessigkeitsgekuehlte

  14. Performance evaluation of passive containment cooling system of an advanced PWR using coupled RELAP5/GOTHIC simulation

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Zheng, E-mail: hzheng@kth.se; Ma, Weimin, E-mail: weimin@kth.se

    2016-12-15

    Highlights: • A coupled model was developed to simulate the simultaneous response of PCS and the containment during LOCA. • The designed PCS can effectively mitigate the accident for a long term. • The loop height has a significant effect on the performance and working mode. • A feed-and-bleed operation for the cooling tank is proposed to further mitigate the accident. • A simplified analytical model for the feed-and-bleed operation is developed. - Abstract: Motivated to investigate the thermal–hydraulic characteristics and performance of a passive containment cooling system (PCS) for a Generation III pressurized water reactor (PWR), a coupled RELAP5/GOTHIC model was developed, which was then employed to simultaneously simulate the transient responses of the PCS and the containment during a large break loss of coolant accident of the reactor. The results show that the PCS is capable of lowering the containment pressure to an acceptable level for a long period (up to 3 days). In a separate-effect study, it was found that the height of the PCS loop plays an important role in determining the flow characteristics and heat removal performance of the PCS. Within the range of the considered loop heights, phase change occurs in the riser of the loop after the height exceeds a specific value (between 13 m and 15 m), below which only single-phase flow takes place. With increasing height of the loop, the heat removal capability increases monotonically at first; however, it is no longer sensitive to the height after two-phase flow appears. Finally, a feed-and-bleed operation for the cooling tank of the PCS was proposed as an enhancement measure of the heat removal capacity, and the simulation results show it further mitigates the accident. Moreover, a simplified analytical model is developed to predict the impact of the feed-and-bleed flowrate on the PCS performance, which can be used in engineering design.

  15. Evaluation of Compatibility of a Gum Mastic Liquid Adhesive and Liquid Adhesive Remover With an Alcoholic Chlorhexidine Gluconate Skin Preparation.

    Science.gov (United States)

    Ryder, Marcia; Duley, Collette

    The compatibility of a 2% chlorhexidine gluconate/70% isopropyl alcohol (CHG/IPA) skin preparation with a gum mastic liquid adhesive (GMLA) and liquid adhesive remover (LAR) was assessed in healthy volunteers. Twenty subjects completed test material combination with microbial sampling at 3- and 7-day time points. Mean log10 reductions from baseline for normal flora were assessed. There was no significant difference in reduction of normal flora on skin prepped with CHG/IPA versus skin prepped with CHG/IPA followed by GMLA or LAR. The conclusion of the study was that the use of GMLA or LAR with CHG/IPA does not affect the antiseptic effectiveness of CHG/IPA.

  16. [Systematic evaluation of retention behavior of carbohydrates in hydrophilic interaction liquid chromatography].

    Science.gov (United States)

    Fu, Qing; Wang, Jun; Liang, Tu; Xu, Xiaoyong; Jin, Yu

    2013-11-01

    A systematic evaluation of retention behavior of carbohydrates in hydrophilic interaction liquid chromatography (HILIC) was performed. The influences of mobile phase, stationary phase and buffer salt on the retention of carbohydrates were investigated. According to the results, the retention time of carbohydrates decreased as the proportion of acetonitrile in mobile phase decreased. Increased time of carbohydrates was observed as the concentration of buffer salt in mobile phase increased. The retention behavior of carbohydrates was also affected by organic solvent and HILIC stationary phase. Furthermore, an appropriate retention equation was used in HILIC mode. The retention equation lnk = a + blnC(B) + cC(B) could quantitatively describe the retention factors of carbohydrates of plant origin with good accuracy: the relative error of the predicted time to actual time was less than 0.3%. The evaluation results could provide guidance for carbohydrates to optimize the experimental conditions in HILIC method development especially for carbohydrate separation

  17. Colorado State University program for developing, testing, evaluating and optimizing solar heating and cooling systems: Project status report for the months of October and November, 1994

    Energy Technology Data Exchange (ETDEWEB)

    1994-12-01

    This report describes a project to develop tools for evaluating solar heating and cooling systems. Current work on this project has been to validate the Florida Solar Energy Center`s (FSEC) models of the Solahart 302K and 302K-AS systems to prepare a rating for the Sacramento Municipal Utility District`s rebate program for solar domestic hot water heaters. A preliminary rating has been issued by FSEC and updated ratings will be released as necessary. Two of the problems that were mentioned in the August/September report are addressed and a tank heat loss test is discussed. Work continues on improving and validating the models.

  18. Evaluation of a pediatric liquid formulation to improve 6-mercaptopurine therapy in children.

    Science.gov (United States)

    Tiphaine, Adam de Beaumais; Hjalgrim, Lisa Lynqsie; Nersting, Jacob; Breitkreutz, Joerg; Nelken, Brigitte; Schrappe, Martin; Stanulla, Martin; Thomas, Caroline; Bertrand, Yves; Leverger, Guy; Baruchel, André; Schmiegelow, Kjeld; Jacqz-Aigrain, Evelyne

    2016-02-15

    6-mercaptopurine (6-MP), a key drug for treatment of acute lymphoblastic leukemia (ALL), has until recently had no adequate formulation for pediatric patients. Several approaches have been taken but the only oral paraben-free 6-MP liquid formulation named Loulla was developed and evaluated in the target population. Preclinical and clinical evaluations were performed according to a Pediatric Investigation Plan, in order to apply for a Pediatric Use Marketing Authorization. The pre-clinical study assessed the maximum tolerated dosage-volume and evaluated local mucosal toxicity of 28 daily administrations in treated compared to controls gold hamsters. The multi-centre clinical study was single-dose, open-label, crossover trial, conducted in 15 ALL children during maintenance therapy. The bioavailability and palatability of a single 50mg fixed dose of Loulla compared to 50mg registered tablets were evaluated in a random order on two consecutive days. Seven blood samples over 9h were obtained each day to determine 6-MP pharmacokinetic parameters, including Tmax, Cmax, AUC0-9 and AUC0-∞. A questionnaire adapted to children testing Loulla palatability and preference for either Loulla or the usual 6-MP tablet was completed. Occurrence of adverse events was determined at study visits by vital sign measurements, patient's spontaneous reporting, investigator's questioning and clinical examination. The preclinical study in gold hamsters showed that dosage-volume of 75 mg/kg/day was well tolerated. The relative bioavailability of liquid Loulla formulation compared to the reference presentation is 76% for AUC0-9 and AUC0-∞ and 80% for Cmax. The taste of Loulla and the mouth feeling after ingestion compare favorably to the tablet. No adverse event occurred. Pharmacokinetic, palatability and safety data support the use of Loulla in children. Copyright © 2015 Elsevier B.V. All rights reserved.

  19. Oil cooled, hermetic refrigerant compressor

    Science.gov (United States)

    English, W.A.; Young, R.R.

    1985-05-14

    A hermetic refrigerant compressor having an electric motor and compressor assembly in a hermetic shell is cooled by oil which is first cooled in an external cooler and is then delivered through the shell to the top of the motor rotor where most of it is flung radially outwardly within the confined space provided by the cap which channels the flow of most of the oil around the top of the stator and then out to a multiplicity of holes to flow down to the sump and provide further cooling of the motor and compressor. Part of the oil descends internally of the motor to the annular chamber to provide oil cooling of the lower part of the motor, with this oil exiting through vent hole also to the sump. Suction gas with entrained oil and liquid refrigerant therein is delivered to an oil separator from which the suction gas passes by a confined path in pipe to the suction plenum and the separated oil drops from the separator to the sump. By providing the oil cooling of the parts, the suction gas is not used for cooling purposes and accordingly increase in superheat is substantially avoided in the passage of the suction gas through the shell to the suction plenum. 3 figs.

  20. Cool visitors

    CERN Document Server

    2006-01-01

    Pictured, from left to right: Tim Izo (saxophone, flute, guitar), Bobby Grant (tour manager), George Pajon (guitar). What do the LHC and a world-famous hip-hop group have in common? They are cool! On Saturday, 1st July, before their appearance at the Montreux Jazz Festival, three members of the 'Black Eyed Peas' came on a surprise visit to CERN, inspired by Dan Brown's Angels and Demons. At short notice, Connie Potter (Head of the ATLAS secretariat) organized a guided tour of ATLAS and the AD 'antimatter factory'. Still curious, lead vocalist Will.I.Am met CERN physicist Rolf Landua after the concert to ask many more questions on particles, CERN, and the origin of the Universe.

  1. Cool Snacks

    DEFF Research Database (Denmark)

    Krogager, Stinne Gunder Strøm; Grunert, Klaus G; Brunsø, Karen

    2016-01-01

    Young people snack and their snacking habits are not always healthy. We address the questions whether it is possible to develop a new snack product that adolescents will find attractive, even though it is based on ingredients as healthy as fruits and vegetables, and we argue that developing...... such a product requires an interdisciplinary effort where researchers with backgrounds in psychology, anthropology, media science, philosophy, sensory science and food science join forces. We present the COOL SNACKS project, where such a blend of competences was used first to obtain thorough insight into young...... people's snacking behaviour and then to develop and test new, healthier snacking solutions. These new snacking solutions were tested and found to be favourably accepted by young people. The paper therefore provides a proof of principle that the development of snacks that are both healthy and attractive...

  2. Majorana One-Tonne Cryostat Cooling Conceptual Feasibility Study

    Energy Technology Data Exchange (ETDEWEB)

    Reid, Douglas J.; Orrell, John L.; Fast, James E.; Aguayo Navarrete, Estanislao

    2011-02-17

    This report evaluates the conceptual plans for a one-tonne (S4) cryostat cooling design. This document is based upon previous design work and experimental results used to evaluate the current MAJORANA DEMONSTRATOR (MJD) thermal design. A feasibility study of a cooling system for S4 based on the MJD thermosyphon experiment is presented. The one-tonne experiment will be a scaled up version of the MJD. There will be many cryostats for the S4 experiment. In this document a cryostat with up to 19 strings of Germanium crystals is analyzed. Aside from an extra outer ring of crystals, the geometry of both systems’ cryostats is very similar. The materials used in the fabrication of both ultra-low background experiments will be underground electroformed copper. The current MJD uses a two-phase liquid-gas cooling system to ensure constant operating temperature. This document presents a theoretical investigation of a cooling system for the S4 experiment and evaluates the heat transfer performance requirements for such a system.

  3. Evaluation of Variable Refrigerant Flow Systems Performance on Oak Ridge National Laboratory s Flexible Research Platform: Part 1 Cooling Season Analysis

    Energy Technology Data Exchange (ETDEWEB)

    Im, Piljae [ORNL; Malhotra, Mini [ORNL; Munk, Jeffrey D [ORNL

    2016-08-01

    This report provides second-year cooling season test results for the multi-year project titled “Evaluation of Variable Refrigeration Flow (VRF) System on Oak Ridge National Laboratory (ORNL)’s Flexible Research Platform (FRP).” The purpose of the second-year project was to (1) evaluate the full- and partload performance of VRF systems compared with an existing baseline heating, ventilation, and airconditioning (HVAC) system, which is a conventional rooftop unit (RTU) variable-air-volume (VAV) system with electric resistance heating and (2) use hourly building energy simulation to evaluate the energy savings potential of using VRF systems in major US cities. The second-year project performance period was from July 2015 through June 2016.

  4. Performance and evaluation of gas engine driven rooftop air conditioning equipment at the Willow Grove (PA) Naval Air Station. Interim report, 1992 cooling season

    Energy Technology Data Exchange (ETDEWEB)

    Armstrong, P.R.; Conover, D.R.

    1993-05-01

    In a field evaluation conducted for the US Department of Energy (DOE) Office of Federal Energy Management Program (FEMP), the Pacific Northwest Laboratory (PNL) examined the performance of a new US energy-related technology under the FEMP Test Bed Demonstration Program. The technology was a 15-ton natural gas engine driven roof top air conditioning unit. Two such units were installed on a naval retail building to provide space conditioning to the building. Under the Test Bed Demonstration Program, private and public sector interests are focused to support the installation and evaluation of new US technologies in the federal sector. Participating in this effort under a Cooperative Research and Development Agreement (CRADA) with DOE were the American Gas Cooling Center, Philadelphia Electric Company, Thermo King Corporation, and the US Naval Air Station at Willow Grove, Pennsylvania. Equipment operating and service data as well as building interior and exterior conditions were secured for the 1992 cooling season. Based on a computer assessment of the building using standard weather data, a comparison was made with the energy and operating costs associated with the previous space conditioning system. Based on performance during the 1992 cooling season and adjusted to a normal weather year, the technology will save the site $6,000/yr in purchased energy costs. An additional $9,000 in savings due to electricity demand ratchet charge reductions will also be realized. Detailed information on the technology, the installation, and the results of the technology test are provided to illustrate the advantages to the federal sector of using this technology. A history of the CRADA development process is also reported.

  5. Influence of cryogenic cooling on surface grinding of stainless steel 316

    Science.gov (United States)

    Manimaran, G.; Pradeep kumar, M.; Venkatasamy, R.

    2014-01-01

    The objective of the present investigation is to evaluate the improvements in the grinding force and surface roughness by the application of LN2 (liquid nitrogen) as a coolant in the cryogenic grinding process. Cryogenic machining is an environment concerned green manufacturing process. The grinding experiments were conducted on stainless steel 316 in three environments, namely, dry, wet and cryogenic cooling. The experimental results show that a reduction in the grinding zone temperature leads to excellent benefits in the machining performance. The cryogenic coolant offers 37% and 13% reduction in the grinding forces compared to dry and wet cooling. The surface roughness under cryogenic cooling is found to produce 59% and 32% lesser values and fewer defects, compared to surfaces ground with dry and wet cooling. The enhancements realized by the delivery pressure of the cryogen, with respect to the grinding forces, and surface roughness were also studied.

  6. Cooled membrane for high sensitivity gas sampling.

    Science.gov (United States)

    Jiang, Ruifen; Pawliszyn, Janusz

    2014-04-18

    A novel sample preparation method that combines the advantages of high surface area geometry and cold surface effect was proposed to achieve high sensitivity gas sampling. To accomplish this goal, a device that enables the membrane to be cooled down was developed for sampling, and a gas chromatograph-mass spectrometer was used for separation and quantification analysis. Method development included investigation of the effect of membrane temperature, membrane size, gas flow rate and humidity. Results showed that high sensitivity for equilibrium sampling, such as limonene sampling in the current study could be achieved by either cooling down the membrane and/or using a large volume extraction phase. On the other hand, for pre-equilibrium extraction, in which the extracted amount was mainly determined by membrane surface area and diffusion coefficient, high sensitivity could be obtained by using thinner membranes with a larger surface and/or a higher sampling flow rate. In addition, humidity showed no significant influence on extraction efficiency, due to the absorption property of the liquid extraction phase. Next, the limit of detection (LOD) was found, and the reproducibility of the developed cooled membrane gas sampling method was evaluated. Results showed that LODs with a membrane diameter of 19mm at room temperature sampling were 9.2ng/L, 0.12ng/L, 0.10ng/L for limonene, cinnamaldehyde and 2-pentadecanone, respectively. Intra- and inter-membrane sampling reproducibility revealed RSD% lower than 8% and 13%, respectively. Results uniformly demonstrated that the proposed cooled membrane device could serve as an alternative powerful tool for future gas sampling. Copyright © 2014 Elsevier B.V. All rights reserved.

  7. Fast cooling techniques for gravitational wave antennas

    CERN Document Server

    Furtado, S R

    2002-01-01

    The resonant-mass technique for the detection of gravitational waves may involve, in the near future, the cooling of very large masses (about 100 tons) from room temperature (300 K) to extreme cryogenic temperatures (20 mK). To cool these detectors to cryogenic temperatures an exchange gas (helium) is used, and the heat is removed from the antenna to the cold reservoir by thermal conduction and natural convection. With the current technique, cooling times of about 1 month can be obtained for cylindrical bar antennas of 2.5 tons. Should this same technique be used to cool a 100 ton spherical antenna the cooling time would be about 10 months, making the operation of these antennas impracticable. In this paper, we study the above-mentioned cooling technique and others, such as thermal switching and forced convection from room temperature to liquid nitrogen temperature (77 K) using an aluminium truncated icosahedron of 19 kg weight and 25 cm diameter.

  8. Design and evaluation of a new Peltier-cooled laser ablation cell with on-sample temperature control.

    Science.gov (United States)

    Konz, Ioana; Fernández, Beatriz; Fernández, M Luisa; Pereiro, Rosario; Sanz-Medel, Alfredo

    2014-01-27

    A new custom-built Peltier-cooled laser ablation cell is described. The proposed cryogenic cell combines a small internal volume (20 cm(3)) with a unique and reliable on-sample temperature control. The use of a flexible temperature sensor, directly located on the sample surface, ensures a rigorous sample temperature control throughout the entire analysis time and allows instant response to any possible fluctuation. In this way sample integrity and, therefore, reproducibility can be guaranteed during the ablation. The refrigeration of the proposed cryogenic cell combines an internal refrigeration system, controlled by a sensitive thermocouple, with an external refrigeration system. Cooling of the sample is directly carried out by 8 small (1 cm×1 cm) Peltier elements placed in a circular arrangement in the base of the cell. These Peltier elements are located below a copper plate where the sample is placed. Due to the small size of the cooling electronics and their circular allocation it was possible to maintain a peephole under the sample for illumination allowing a much better visualization of the sample, a factor especially important when working with structurally complex tissue sections. The analytical performance of the cryogenic cell was studied using a glass reference material (SRM NIST 612) at room temperature and at -20°C. The proposed cell design shows a reasonable signal washout (signal decay within less than 10 s to background level), high sensitivity and good signal stability (in the range 6.6-11.7%). Furthermore, high precision (0.4-2.6%) and accuracy (0.3-3.9%) in the isotope ratio measurements were also observed operating the cell both at room temperature and at -20°C. Finally, experimental results obtained for the cell application to qualitative elemental imaging of structurally complex tissue samples (e.g. eye sections from a native frozen porcine eye and fresh flower leaves) demonstrate that working in cryogenic conditions is critical in such

  9. Osmosis process for leachate treatment in industrial platform: Economic and performances evaluations to zero liquid discharge.

    Science.gov (United States)

    Cingolani, Diego; Eusebi, Anna Laura; Battistoni, Paolo

    2017-12-01

    The industrial processes require large quantities of water. The presence of discharges results not only in significant environmental impact but implies wastage of water resources. This problem could be solved treating and reusing the produced wastewaters and applying the new zero liquid discharge approach. This paper discusses the design and the performances of reverse osmosis membranes for the upgrading of full scale platform for industrial liquid wastes. The final effluent from the ultrafiltration unit of the full scale plant was monitored to design the reverse osmosis unit. Previous modelling phase was used to evaluate the specific ordinary and maintenance costs and the final effluent quality (2.7 €/m 3 ). The system was designed in triple stages at different operative pressures. The economic feasibility and the payback period of the technology at different percentages of produced permeate were determined. The recovery of 90% was identified as profitable for the reverse osmosis application. One experimental pilot plant applying the reverse osmosis was used to test the final effluent. Moreover, the same flow was treated with second pilot system based on the forward osmosis process. The final efficiencies were compared. Removals higher than 95% using the reverse system were obtained for the main macropollutants and ions. No sustainable applicability of the forward osmosis was determined. Copyright © 2016 Elsevier Ltd. All rights reserved.

  10. Validation evaluation of the technological process of leonurus turkestanicus liquid extract production

    Directory of Open Access Journals (Sweden)

    Олеся Владимировна Сермухамедова

    2016-01-01

    Full Text Available Aim. The transfer of Leonurus turkestanicus liquid extract production technology and its validation at LLC «FitOleum» (GMP compliance report conclusion CT PK 1617-2006 «Good Manufacturing Practice. Remedies production. Basic provisions» № 18, Nov. 21, 2014..Methods. Different known statistical methods have been used to evaluate and to interpret both technological parameters and indicators that were determined during quality control of herbal material, intermediate product, and final product. A Statistical process control (SPC concept is applied as a basis for all accepted international instruments ICH Q8 «Pharmaceutical Development», ICH Q10 «Pharmaceutical Quality System», PAT Concept, and FDA Guidance for Process Validation.Results. As a result of research normative documents that regulate manufacturing process in the test conditions have been developed. A comparable data across technological parameters of three consistently manufactured test production series have been obtained, as well as validity of the extract production technological process has been proved.Conclusion. On the basis of research, the experimental-industrial procedure for Leonurus turkestanicus herb liquid extract production at the LLC «FitOleum» has been developed

  11. Performance evaluation of integrated solid-liquid wastes treatment technology in palm oil industry

    Science.gov (United States)

    Amelia, J. R.; Suprihatin, S.; Indrasti, N. S.; Hasanudin, U.; Fujie, K.

    2017-05-01

    The oil palm industry significantly contributes to environmental degradation if without waste management properly. The newest alternative waste management that might be developed is by utilizing the effluent of POME anaerobic digestion with EFB through integrated anaerobic decomposition process. The aim of this research was to examine and evaluate the integrated solid-liquid waste treatment technology in the view point of greenhouse gasses emission, compost, and biogas production. POME was treated in anaerobic digester with loading rate about 1.65 gCOD/L/day. Treated POME with dosis of 15 and 20 L/day was sprayed to the anaerobic digester that was filled of 25 kg of EFB. The results of research showed that after 60 days, the C/N ratio of EFB decreased to 12.67 and 10.96 for dosis of treated POME 15 and 20 L/day, respectively. In case of 60 day decomposition, the integrated waste treatment technology could produce 51.01 and 34.34 m3/Ton FFB which was equivalent with 636,44 and 466,58 kgCO2e/ton FFB for dosis of treated POME 15 and 20 L/day, respectively. The results of research also showed that integrated solid-liquid wastes treatment technology could reduce GHG emission about 421.20 and 251.34 kgCO2e/ton FFB for dosis of treated POME 15 and 20 L/day, respectively.

  12. Evaluation of transport properties of nanofiltration membranes exposed to radioactive liquid waste

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Elizabeth E.M.; Barbosa, Celina C.R.; Bastos, Edna T.R., E-mail: eemo@ien.gov.br [Instituto de Engenharia Nuclear (IEN/CNEN-RJ), Rio de Janeira, RJ (Brazil); Afonso, Julio C., E-mail: Julio@iq.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Inst. de Quimica. Dept. de Quimica Analitica

    2011-07-01

    The application of membrane separation processes (PSM) for treatment of radioactive waste requires the selection of a suitable membrane for the treatment of waste, as the membrane will be directly exposed to the radioactive liquid waste, and also exposed to ionizing radiation. The nanofiltration membrane is most suitable for treatment of radioactive waste, since it has high rejection of multivalent ions. Usually the membranes are made of polymers and depending on the composition of the waste, type and dose of radiation absorbed may be changes in the structure of the membrane, resulting in loss of its transport properties. We tested two commercial nanofiltration membranes: NF and SW Dow/Filmtec. The waste liquid used was obtained in the process of conversion of uranium hexafluoride gas to solid uranium dioxide, known as 'carbonated water'. The membranes were characterized as their transport properties (hydraulic permeability, permeate flux and salt rejection) before and after their immersion in the waste for 24 hours. The surface of the membranes was also evaluated by SEM and FTIR. It was observed that in both the porosity of the membrane selective layer was altered, but not the membrane surface charge, which is responsible for the selectivity of the membrane. The NF membranes and SW showed uranium ion rejection of 64% and 55% respectively. (author)

  13. Evaluation of a liquid dispenser for assay development and enzymology in 1536-well format.

    Science.gov (United States)

    Butendeich, Heike; Pierret, Noëlle M; Numao, Shin

    2013-06-01

    Although developments in liquid dispensers have made the use of 1536-well plates for high-throughput screening (HTS) standard, there is still a gap in dispenser technology for performing matrix experiments with several components. Experiments such as those performed during assay development and enzymological studies are therefore still performed by manual pipetting in lower-density plates. We have evaluated a new dispenser, the Certus liquid dispenser (Gyger Fluidics GmbH, Switzerland), that is capable of flexible dispensing in 1536-well format, with a dead volume of less than 200 µL. Taking advantage of the precision of the dispenser for volumes down to 50 nL, we have created concentration gradients on plates by dispensing different volumes of reagent and then backfilling with buffer. Using this method and the flexibility of the dispenser software, we have performed several multidimensional experiments varying two to three components, including an assay development for an HTS, a mode of inhibition study, and a cofactor optimization, in which we determined 32 KM values. Overall, the flexibility of the plate layout for multiple components, the accuracy to dispense volumes ranging 2 log orders, and minimal reagent usage enable this dispenser for complex biochemical experiments.

  14. Cooling lubricants; Kuehlschmierstoffe

    Energy Technology Data Exchange (ETDEWEB)

    Pfeiffer, W. [Berufsgenossenschaftliches Inst. fuer Arbeitssicherheit, St. Augustin (Germany); Breuer, D. [Berufsgenossenschaftliches Inst. fuer Arbeitssicherheit, St. Augustin (Germany); Blome, H. [Berufsgenossenschaftliches Inst. fuer Arbeitssicherheit, St. Augustin (Germany); Deininger, C. [Berufsgenossenschaftliches Inst. fuer Arbeitssicherheit, St. Augustin (Germany); Hahn, J.U. [Berufsgenossenschaftliches Inst. fuer Arbeitssicherheit, St. Augustin (Germany); Kleine, H. [Berufsgenossenschaftliches Inst. fuer Arbeitssicherheit, St. Augustin (Germany); Nies, E. [Berufsgenossenschaftliches Inst. fuer Arbeitssicherheit, St. Augustin (Germany); Pflaumbaum, W. [Berufsgenossenschaftliches Inst. fuer Arbeitssicherheit, St. Augustin (Germany); Stockmann, R. [Berufsgenossenschaftliches Inst. fuer Arbeitssicherheit, St. Augustin (Germany); Willert, G. [Berufsgenossenschaftliches Inst. fuer Arbeitssicherheit, St. Augustin (Germany); Sonnenschein, G. [Maschinenbau- und Metall-Berufsgenossenschaft, Duesseldorf (Germany)

    1996-08-01

    As a rule, the base substances used are certain liquid hydrocarbons from mineral oils as well as from native and synthetic oils. Through the addition of further substances the cooling lubricant takes on the particular qualities required for the use in question. Employees working with cooling lubricants are exposed to various hazards. The assessment of the concentrations at the work station is carried out on the basis of existing technical rules for contact with hazardous substances. However, the application/implementation of compulsory investigation and supervision in accordance with these rules is made difficult by the fact that cooling lubricants are, as a rule, made up of complicated compound mixtures. In addition to protecting employees from exposure to mists and vapours from the cooling lubricants, protection for the skin is also of particular importance. Cooling lubricants should not, if at all possible, be brought into contact with the skin. Cleansing the skin and skin care is just as important as changing working clothes regularly, and hygiene and cleanliness at the workplace. Unavoidable emissions are to be immediately collected at the point where they arise or are released and safely disposed of. This means taking into account all sources of emissions. The programme presented in this report therefore gives a very detailed account of the individual protective measures and provides recommendations for the design of technical protection facilities. (orig./MG) [Deutsch] Als Basisstoffe dienen in der Regel bestimmte fluessige Kohlenwasserstoffverbindungen aus Mineraloelen sowie aus nativen oder synthetischen Oelen. Durch die Zugabe von weiteren Stoffen erlangt der Kuehlschmierstoff seine fuer den jeweiligen Anwendungsabfall geforderten Eigenschaften. Beschaeftigte, die mit Kuehlschmierstoffen umgehen, sind unterschiedliche Gefahren ausgesetzt. Die Beurteilung der Kuehlschmierstoffkonzentrationen in der Luft am Arbeitsplatz erfolgt auf der Grundlage bestehender

  15. Critical evaluation of equilibrium constants involving 8-hydroxyquinoline and its metal chelates critical evaluation of equilibrium constants in solution : part b : equilibrium constants of liquid-liquid distribution systems

    CERN Document Server

    Stary, J

    1979-01-01

    Critical Evaluation of Equilibrium Constants Involving 8-Hydroxyquinoline and Its Metal Chelates presents and evaluates the published data on the solubility, dissociation, and liquid-liquid distribution of oxine and its metal chelates to recommend the most reliable numerical data. This book explores the dissociation constants of oxine in aqueous solutions.Organized into four chapters, this book begins with an overview of the characteristics of 8-hydroxyquinoline (oxine). This text then examines the total solubility of oxine in aqueous solution at different pH values. Other chapters consider th

  16. Preparation and evaluation of pillararene bonded silica gel stationary phases for high performance liquid chromatography.

    Science.gov (United States)

    Zhao, Wenjie; Chu, Jianxiang; Xie, Fuwei; Duan, Qunpeng; He, Lijun; Zhang, Shusheng

    2017-02-17

    Pillararene bonded stationary phases for high performance liquid chromatography were prepared using 3-aminopropyltriethoxysilane as coupling reagent. The structure of the new materials was characterized by infrared spectroscopy, elemental analysis and thermogravimetric analysis. The chromatographic performance and retention mechanism of the new stationary phases were evaluated in reversed-phase mode compared with C18 using different solute probes including Tanaka test solutes, polycyclic aromatic hydrocarbons, phenols and aromatic positional isomers. The new stationary phases could provide various interactions for different solutes, such as hydrophobic, hydrogen bonding, π-π and inclusion interactions. The synergistic effects resulting from aromatic rings, oxygen atoms, alkyl linkers and cavities in the new host molecules improved the separation selectivity by multiple retention mechanisms. Such hybrid stationary phases can provide more versatility and have great potential for the analysis of complex samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  17. Thermal performance evaluation of the Suncatcher SH-11 (liquid) solar collector

    Science.gov (United States)

    1980-01-01

    The procedures used and the results obtained during the evaluation test program on the Solar Unlimited, Inc., Suncatcher SH-11 (liquid) solar collector are presented. The flat-plate collector case assembly is made of .08 inch aluminum 3003 H14 riveted with fiberglass board insulation. The absorber consists of collared aluminum fins mechanically bonded to 3/8 inch copper tubing and coated with 3M Nextel black. Water is used as the working fluid. The glazing is made of a single glass, 1/8 inch water white, tempered and antireflective. The collector weight is 85 pounds with overall external dimensions of about 35.4 in x 82.0 in x 4.0 in. Thermal performance data on the Solar Unlimited Suncatcher SH-11 solar collector under simulated conditions were conducted using the MSFC Solar Simulator.

  18. EVALUATION OF THE VIABILITY OF PLEUROTUS SPP. STRAINS AFTER LIQUID NITROGEN CRYOPRESERVATION

    Directory of Open Access Journals (Sweden)

    Lara-Herrera Isabel

    1998-01-01

    Full Text Available Viability of 6 mushroom strains of the Pleurotus genus (2 from P. djamor var. djamor, 1 from P. ostreatus var. ostreatus, 2 from P. ostreatus var. columbinus and 1 from P. pulmonarius after liquid nitrogen cryopreservation (-196º was evaluated. The contact time for the mycelia of these strains with the cryoprotectant (glycerol was studied 1, 2 and 3 hours before freezing. We also tested the effect of different times (5, 10 and 15 minutes and temperatures (30, 45 and 60ºC of the thawing system for mycelial recovery. The results showed a marked tendency toward faster mycelial recovery when samples were thawed at 30ºC, while at 60ºC no recovery was observed. A change in thawing and contact times with the cryoprotectant did not affect the results significantly, as the thawing temperature and strain employed affected.

  19. Multicentre evaluation of Capture Assay Radim Liquid Allergen for measurement of specific IgE antibodies.

    Science.gov (United States)

    Banfi, G; Ferrara, F; Bonini, P; Colombo, G; Plebani, M; Borghesan, F; Faggian, D; Caputo, M; Andri, L; Senna, G E

    1995-10-01

    A multicentre trial of Capture Assay Radim Liquid Allergen was performed to define the sensitivity, specificity and clinical reliability of the system in diagnostic allergology. The results of the evaluation were compared with clinical data and in vivo testing. Good agreement was obtained for Dermatophagoides pteronyssinus (D1), Cat's epithelium (E1), Betula verrucosa (T3) and Olea europea (T9), Artemisia vulgaris (W6) and Parietaria officinalis (W19). Some spreading of data was observed for Artemisia absinthium (W5), Cynodon dactylon (G2), and Lolium perenne (G5). We found a high number of negative cases for Alternaria alternata (M6). The advantages offered by the system are the automation, the small quantity of serum requested, the supply of quantitative results in international units of specific IgE, the user-friendly software. The data are sufficiently reliable for the diagnostic system to be introduced into the clinical laboratory allergological routine.

  20. Storage of liquid, radioactive wastes

    Energy Technology Data Exchange (ETDEWEB)

    Hesky, H.; Wunderer, A.

    1983-08-02

    When reprocessing spent nuclear fuel, liquid radioactive wastes are obtained and, is generated from fission within the waste, and oxyhydrogen may be set free by radiolysis. The fission heat generated within the liquid wastes is carried off by evaporation cooling and, the vapor so formed condensed and recycled into the storage vessel for the liquid wastes. The oxyhydrogen is then diluted with the vapor formed during evaporation cooling and converted catalytically.

  1. Rigorous evaluation of chemical measurement uncertainty: liquid chromatographic analysis methods using detector response factor calibration

    Science.gov (United States)

    Toman, Blaza; Nelson, Michael A.; Bedner, Mary

    2017-06-01

    Chemical measurement methods are designed to promote accurate knowledge of a measurand or system. As such, these methods often allow elicitation of latent sources of variability and correlation in experimental data. They typically implement measurement equations that support quantification of effects associated with calibration standards and other known or observed parametric variables. Additionally, multiple samples and calibrants are usually analyzed to assess accuracy of the measurement procedure and repeatability by the analyst. Thus, a realistic assessment of uncertainty for most chemical measurement methods is not purely bottom-up (based on the measurement equation) or top-down (based on the experimental design), but inherently contains elements of both. Confidence in results must be rigorously evaluated for the sources of variability in all of the bottom-up and top-down elements. This type of analysis presents unique challenges due to various statistical correlations among the outputs of measurement equations. One approach is to use a Bayesian hierarchical (BH) model which is intrinsically rigorous, thus making it a straightforward method for use with complex experimental designs, particularly when correlations among data are numerous and difficult to elucidate or explicitly quantify. In simpler cases, careful analysis using GUM Supplement 1 (MC) methods augmented with random effects meta analysis yields similar results to a full BH model analysis. In this article we describe both approaches to rigorous uncertainty evaluation using as examples measurements of 25-hydroxyvitamin D3 in solution reference materials via liquid chromatography with UV absorbance detection (LC-UV) and liquid chromatography mass spectrometric detection using isotope dilution (LC-IDMS).

  2. Rigorous evaluation of chemical measurement uncertainty: Liquid chromatographic analysis methods using detector response factor calibration.

    Science.gov (United States)

    Toman, Blaza; Nelson, Michael A; Bedner, Mary

    2017-06-01

    Chemical measurement methods are designed to promote accurate knowledge of a measurand or system. As such, these methods often allow elicitation of latent sources of variability and correlation in experimental data. They typically implement measurement equations that support quantification of effects associated with calibration standards and other known or observed parametric variables. Additionally, multiple samples and calibrants are usually analyzed to assess accuracy of the measurement procedure and repeatability by the analyst. Thus, a realistic assessment of uncertainty for most chemical measurement methods is not purely bottom-up (based on the measurement equation) or top-down (based on the experimental design), but inherently contains elements of both. Confidence in results must be rigorously evaluated for the sources of variability in all of the bottom-up and top-down elements. This type of analysis presents unique challenges due to various statistical correlations among the outputs of measurement equations. One approach is to use a Bayesian hierarchical (BH) model which is intrinsically rigorous, thus making it a straightforward method for use with complex experimental designs, particularly when correlations among data are numerous and difficult to elucidate or explicitly quantify. In simpler cases, careful analysis using GUM Supplement 1 (MC) methods augmented with random effects meta analysis yields similar results to a full BH model analysis. In this article we describe both approaches to rigorous uncertainty evaluation using as examples measurements of 25-hydroxyvitamin D3 in solution reference materials via liquid chromatography with UV absorbance detection (LC-UV) and liquid chromatography mass spectrometric detection using isotope dilution (LC-IDMS).

  3. Evaluation of nanoflow liquid chromatography high resolution mass spectrometry for pesticide residue analysis in food.

    Science.gov (United States)

    Moreno-González, David; Pérez-Ortega, Patricia; Gilbert-López, Bienvenida; Molina-Díaz, Antonio; García-Reyes, Juan F; Fernández-Alba, Amadeo R

    2017-08-25

    This article reports on the evaluation of nanoflow liquid chromatography-mass spectrometry (LC-MS) for pesticide residue analysis in food. The approach is based on the use of reversed-phase C18nano columns with an integrated emitter, so that separation, ionization and detection are performed minimizing dead volumes. The use of nanoflow not only increases ionization efficiency and minimizes ionization suppression but also boost sensitivity compared to analytical-scale LC-MS methods. The nanoflow LC system was combined with full-scan high resolution mass spectrometry using a Q-Exactive Orbitrap instrument. The analytical performance was assessed for over 60 representative pesticides in five representative commodities (tomato, baby food, orange, fruit-based jam and olive oil). The sensitivity achieved with this configuration enables the implementation of high dilution factors (eg. 1:20, 1:50 or beyond) in pesticide residue workflows without compromising sensitivity, featuring limits of quantitation in the low ng kg-1 range. Using this dilution factors, signal suppression was found negligible in most cases (<10% in most cases, especially with 1:50 dilution), so that matrix-matched standards may be skipped, thus simplifying laboratory workflows. The robustness of the nanoflow LC system and its capability to withstand long analytical runs was also evaluated. Appropriate precision in terms of peak area and retention time was obtained at different concentration levels for over 125 injections without any instrument servicing. The main benefits of the nanoflow liquid chromatography approach are the high sensitivity gain and the outstanding reduction in matrix effects thanks to the high sample dilution factors that can be implemented, along with the substantial reduction in solvent usage. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. ATLAS' major cooling project

    CERN Multimedia

    2005-01-01

    In 2005, a considerable effort has been put into commissioning the various units of ATLAS' complex cryogenic system. This is in preparation for the imminent cooling of some of the largest components of the detector in their final underground configuration. The liquid helium and nitrogen ATLAS refrigerators in USA 15. Cryogenics plays a vital role in operating massive detectors such as ATLAS. In many ways the liquefied argon, nitrogen and helium are the life-blood of the detector. ATLAS could not function without cryogens that will be constantly pumped via proximity systems to the superconducting magnets and subdetectors. In recent weeks compressors at the surface and underground refrigerators, dewars, pumps, linkages and all manner of other components related to the cryogenic system have been tested and commissioned. Fifty metres underground The helium and nitrogen refrigerators, installed inside the service cavern, are an important part of the ATLAS cryogenic system. Two independent helium refrigerators ...

  5. Intrinsic Evaporative Cooling by Hygroscopic Earth Materials

    Directory of Open Access Journals (Sweden)

    Alexandra R. Rempel

    2016-08-01

    Full Text Available The phase change of water from liquid to vapor is one of the most energy-intensive physical processes in nature, giving it immense potential for cooling. Diverse evaporative cooling strategies have resulted worldwide, including roof ponds and sprinklers, courtyard fountains, wind catchers with qanats, irrigated green roofs, and fan-assisted evaporative coolers. These methods all require water in bulk liquid form. The evaporation of moisture that has been sorbed from the atmosphere by hygroscopic materials is equally energy-intensive, however, yet has not been examined for its cooling potential. In arid and semi-arid climates, hygroscopic earth buildings occur widely and are known to maintain comfortable indoor temperatures, but evaporation of moisture from their walls and roofs has been regarded as unimportant since water scarcity limits irrigation and rainfall; instead, their cool interiors are attributed to well-established mass effects in delaying the transmission of sensible gains. Here, we investigate the cooling accomplished by daily cycles of moisture sorption and evaporation which, requiring only ambient humidity, we designate as “intrinsic” evaporative cooling. Connecting recent soil science to heat and moisture transport studies in building materials, we use soils, adobe, cob, unfired earth bricks, rammed earth, and limestone to reveal the effects of numerous parameters (temperature and relative humidity, material orientation, thickness, moisture retention properties, vapor diffusion resistance, and liquid transport properties on the magnitude of intrinsic evaporative cooling and the stabilization of indoor relative humidity. We further synthesize these effects into concrete design guidance. Together, these results show that earth buildings in diverse climates have significant potential to cool themselves evaporatively through sorption of moisture from humid night air and evaporation during the following day’s heat. This finding

  6. Design, evaluation and recommedation effort relating to the modification of a residential 3-ton absorption cycle cooling unit for operation with solar energy

    Science.gov (United States)

    Merrick, R. H.; Anderson, P. P.

    1973-01-01

    The possible use of solar energy powered absorption units to provide cooling and heating of residential buildings is studied. Both, the ammonia-water and the water-lithium bromide cycles, are considered. It is shown that the air cooled ammonia water unit does not meet the criteria for COP and pump power on the cooling cycle and the heat obtained from it acting as a heat pump is at too low a temperature. If the ammonia machine is water cooled it will meet the design criteria for cooling but can not supply the heating needs. The water cooled lithium bromide unit meets the specified performance for cooling with appreciably lower generator temperatures and without a mechanical solution pump. It is recommeded that in the demonstration project a direct expansion lithium bromide unit be used for cooling and an auxiliary duct coil using the solar heated water be employed for heating.

  7. Progress of thermal hydraulic evaluation methods and experimental studies on a sodium-cooled fast reactor and its safety in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Kamide, Hideki, E-mail: kamide.hideki@jaea.go.jp; Ohshima, Hiroyuki, E-mail: ohshima.hiroyuki@jaea.go.jp; Sakai, Takaaki, E-mail: sakai.takaaki@jaea.go.jp; Tanaka, Masaaki, E-mail: tanaka.masaaki@jaea.go.jp

    2017-02-15

    Highlights: • Thermal hydraulic issues for safety design criteria of sodium cooled fast reactors. • Measurement of velocity data in a subchannel surrounded by wire wrapped fuel-pins. • Statistical evaluation of core hot spot temperature during natural circulation. • Simulation of dynamics of molten fuel pool in a core disruptive accident. • V&V procedure of a multi-dimensional thermal hydraulic code on thermal striping. - Abstract: In the framework of the Generation-IV International Forum, the safety design criteria (SDC) incorporating safety-related R&D results on innovative technologies and lessons learned from Fukushima Dai-ichi nuclear power plants accident has been established to provide the set of general criteria for the safety designs of structures, systems and components of Generation-IV Sodium-cooled Fast Reactors (Gen-IV SFRs). A number of thermal-hydraulic evaluations are necessary to meet the concept of the criteria in the design studies of Gen-IV SFRs. This paper focuses on four kinds of thermal-hydraulic issues associated with the SDC, i.e., fuel subassembly thermal-hydraulics, natural circulation decay heat removal, core disruptive accidents, and thermal striping. Progress of evaluation methods on these issues is shown with activities on verification and validation (V&V) and experimental studies towards commercialization of SFR in Japan. These evaluation methods are planned to be eventually integrated into a comprehensive numerical simulation system that can be applied to all possible phenomena in SFR systems and that can be expected to become an effective tool for the development of human resource and the handing our knowledge and technologies down.

  8. Living Liquid: Design and Evaluation of an Exploratory Visualization Tool for Museum Visitors.

    Science.gov (United States)

    Ma, J; Liao, I; Ma, Kwan-Liu; Frazier, J

    2012-12-01

    Interactive visualizations can allow science museum visitors to explore new worlds by seeing and interacting with scientific data. However, designing interactive visualizations for informal learning environments, such as museums, presents several challenges. First, visualizations must engage visitors on a personal level. Second, visitors often lack the background to interpret visualizations of scientific data. Third, visitors have very limited time at individual exhibits in museums. This paper examines these design considerations through the iterative development and evaluation of an interactive exhibit as a visualization tool that gives museumgoers access to scientific data generated and used by researchers. The exhibit prototype, Living Liquid, encourages visitors to ask and answer their own questions while exploring the time-varying global distribution of simulated marine microbes using a touchscreen interface. Iterative development proceeded through three rounds of formative evaluations using think-aloud protocols and interviews, each round informing a key visualization design decision: (1) what to visualize to initiate inquiry, (2) how to link data at the microscopic scale to global patterns, and (3) how to include additional data that allows visitors to pursue their own questions. Data from visitor evaluations suggests that, when designing visualizations for public audiences, one should (1) avoid distracting visitors from data that they should explore, (2) incorporate background information into the visualization, (3) favor understandability over scientific accuracy, and (4) layer data accessibility to structure inquiry. Lessons learned from this case study add to our growing understanding of how to use visualizations to actively engage learners with scientific data.

  9. Renewable Heating and Cooling

    Science.gov (United States)

    Renewable heating and cooling is a set of alternative resources and technologies that can be used in place of conventional heating and cooling technologies for common applications such as water heating, space heating, space cooling and process heat.

  10. Evaluation of Tool Path Strategy and Cooling Condition Effects on the Cutting Force and Surface Quality in Micromilling Operations

    Directory of Open Access Journals (Sweden)

    Ugur Koklu

    2017-10-01

    Full Text Available Compared to milling on a macro scale, the micromilling process has several cumbersome points that need to be addressed. Rapid tool wear and fracture, severe burr formation, and poor surface quality are the major problems encountered in the micromilling process. This study aimed to reveal the effect of cutting path strategies on the cutting force and surface quality in the micromilling of a pocket. The hatch zigzag tool path strategy and the contour climb tool path strategy under different cooling conditions (e.g., dry, air blow, and flood coolant at fixed cutting parameters. The micromilling tests revealed that better results were obtained with the use of the contour tool path strategy in terms of cutting forces (by up to ~43% compared to the dry condition and surface quality (by up to ~44% compared to the air blow condition when compared to the hatch tool path strategy. In addition, the flood coolant reduces the cutting temperature and eliminates chips to significantly enhance the quality of the micro milled surface.

  11. Restaurant food cooling practices.

    Science.gov (United States)

    Brown, Laura Green; Ripley, Danny; Blade, Henry; Reimann, Dave; Everstine, Karen; Nicholas, Dave; Egan, Jessica; Koktavy, Nicole; Quilliam, Daniela N

    2012-12-01

    Improper food cooling practices are a significant cause of foodborne illness, yet little is known about restaurant food cooling practices. This study was conducted to examine food cooling practices in restaurants. Specifically, the study assesses the frequency with which restaurants meet U.S. Food and Drug Administration (FDA) recommendations aimed at reducing pathogen proliferation during food cooling. Members of the Centers for Disease Control and Prevention's Environmental Health Specialists Network collected data on food cooling practices in 420 restaurants. The data collected indicate that many restaurants are not meeting FDA recommendations concerning cooling. Although most restaurant kitchen managers report that they have formal cooling processes (86%) and provide training to food workers on proper cooling (91%), many managers said that they do not have tested and verified cooling processes (39%), do not monitor time or temperature during cooling processes (41%), or do not calibrate thermometers used for monitoring temperatures (15%). Indeed, 86% of managers reported cooling processes that did not incorporate all FDA-recommended components. Additionally, restaurants do not always follow recommendations concerning specific cooling methods, such as refrigerating cooling food at shallow depths, ventilating cooling food, providing open-air space around the tops and sides of cooling food containers, and refraining from stacking cooling food containers on top of each other. Data from this study could be used by food safety programs and the restaurant industry to target training and intervention efforts concerning cooling practices. These efforts should focus on the most frequent poor cooling practices, as identified by this study.

  12. A simplified simulation model for a HPDC die with conformal cooling channels

    Science.gov (United States)

    Frings, Markus; Behr, Marek; Elgeti, Stefanie

    2017-10-01

    In general, the cooling phase of the high-pressure die casting process is based on complex physical phenomena: so-lidification of molten material; heat exchange between cast part, die and cooling fluid; turbulent flow inside the cooling channels that needs to be considered when computing the heat flux; interdependency of properties and temperature of the cooling liquid. Intuitively understanding and analyzing all of these effects when designing HPDC dies is not feasible. A remedy that has become available is numerical design, based for example on shape optimization methods. However, current computing power is not sufficient to perform optimization while at the same time fully resolving all physical phenomena. But since in HPDC suitable objective functions very often lead to integral values, e.g., average die temperature, this paper identifies possible simplifications in the modeling of the cooling phase. As a consequence, the computational effort is reduced to an acceptable level. A further aspect that arises in the context of shape optimization is the evaluation of shape gradients. The challenge here is to allow for large shape deformations without remeshing. In our approach, the cooling channels are described by their center lines. The flow profile of the cooling fluid is then estimated based on experimental data found in literature for turbulent pipe flows. In combination, the heat flux throughout cavity, die, and cooling channel can be described by one single advection-diffusion equation on a fixed mesh. The parameters in the equation are adjusted based on the position of cavity and cooling channel. Both results contribute towards a computationally efficient, yet accurate method, which can be employed within the frame of shape optimization of cooling channels in HPDC dies.

  13. Evaluation of aminoacids in irradiated beans (Vigna unguiculata (L.) Walp) by high performance liquid chromatography (HPLC)

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Keila S. Cople; Souza, Luciana B.; Coelho, Maysa J.; Lima, Antonio L. Santos; Hernandes, Nilber K. [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil). Secao de Engenharia Nuclear]. E-mail: keila@ime.eb.br; Godoy, Ronoel L.O. [EMBRAPA Agroindustria de Alimentos, Rio de Janeiro, RJ (Brazil)]. E-mail: ronoel@ctaa.embrapa.br

    2007-07-01

    Fradinho-bean (Vigna unguiculata (L.) Walp) is originated from Africa and is known in Brazil as 'caupi', 'corda' or 'macassar'. It is grown in the interior of Northeast Brazil (semi-arid region) and can be found in parts of the North, being one of the most important components of people's diet in those regions. The Northeast area produces around 429,375 ton of fradinho-bean per year. Leguminous plants are very important sources of proteins, vitamins, carbohydrates and minerals. This kind of bean is an excellent source of proteins (around 23- 25% of its nutritional content), being superior to regular beans (Phaseolus vulgaris). The irradiation process is an alternative to avoid post-harvesting losses, without changing the nutritional value of food. This study has the objective to evaluate the effect of different gamma irradiation doses (0.0; 0.5; 1.0; 2.5; 5.0 and 10.0 kGy) on aminoacid content of fradinho-bean by high performance liquid chromatography (HPLC) and the accompanying of the grains during storage time of 6 months. After irradiation, the bean grains went through a milling process in order to make flour for posterior extraction. A liquid chromatographer Waters, model Alliance 2695, with fluorescent detector Waters 2475, having a mobile phase with gradient elution of sodium acetate. acetonitrile and Milli-Q water, was employed. The flux used was 1 mL/min and the injection volume of 10 {mu}L. The column (C 18 150.0 x 3.9 mm) was kept at 36 deg C. The results show that gamma irradiation is a promise process for fradinho bean during conservation storage time of 6 months, until the dose of 10.0 kGy. Even the most radio-sensitive aminoacids like aromatics and basic lateral chains were preserved. (author)

  14. Evaluation of Liquid and Bait Insecticides against the Dark Rover Ant (Brachymyrmex patagonicus

    Directory of Open Access Journals (Sweden)

    Javier G. Miguelena

    2014-11-01

    Full Text Available Dark rover ants (Brachymyrmex patagonicus, Mayr are an exotic ant species native to South America that has recently spread through the southern US. We evaluated the residual activity of three liquid insecticides (indoxacarb, fipronil and lambda-cyhalothrin as potential barrier treatments against these ants. The factors we considered include the use of a porous or non-porous surface, a short or long exposure time and the changes in insecticide activity after treatment during a 90 day period. We also tested the effect of baits containing three different active ingredients (imidacloprid, sodium tetraborate and indoxacarb on colony fragments of this species for a 15 day period. Both lambda-cyhalothrin® and indoxacarb® resulted in high levels of ant mortality up to 90 days after application. The results of exposure to fipronil® resembled those from the control treatment. Application of insecticides on a porous surface and the shorter exposure time generally resulted in greater ant survival. Of the baits tested, only the imidacloprid based one decreased ant survival significantly during the evaluation period. Within three days, the imidacloprid bait produced over 50% mortality which increased to over 95% by the end of the experiment. Results from the other two bait treatments were not significantly different from the control.

  15. A Process for Evaluating Adverse Environmental Impacts by Cooling-Water System Entrainment at a California Power Plant

    Directory of Open Access Journals (Sweden)

    C.P. Ehrler

    2002-01-01

    Full Text Available A study to determine the effects of entrainment by the Diablo Canyon Power Plant (DCPP was conducted between 1996 and 1999 as required under Section 316(b of the Clean Water Act. The goal of this study was to present the U.S. Environmental Protection Agency (EPA and Central Coast Regional Water Quality Control Board (CCRWQCB with results that could be used to determine if any adverse environmental impacts (AEIs were caused by the operation of the plant’s cooling-water intake structure (CWIS. To this end we chose, under guidance of the CCRWQCB and their entrainment technical working group, a unique approach combining three different models for estimating power plant effects: fecundity hindcasting (FH, adult equivalent loss (AEL, and the empirical transport model (ETM. Comparisons of the results from these three approaches provided us a relative measure of confidence in our estimates of effects. A total of 14 target larval fish taxa were assessed as part of the DCPP 316(b. Example results are presented here for the kelp, gopher, and black-and-yellow (KGB rockfish complex and clinid kelpfish. Estimates of larval entrainment losses for KGB rockfish were in close agreement (FH is approximately equals to 550 adult females per year, AEL is approximately equals to 1,000 adults [male and female] per year, and ETM = larval mortality as high as 5% which could be interpreted as ca. 2,600 1 kg adult fish. The similar results from the three models provided confidence in the estimated effects for this group. Due to lack of life history information needed to parameterize the FH and AEL models, effects on clinid kelpfish could only be assessed using the ETM model. Results from this model plus ancillary information about local populations of adult kelpfish suggest that the CWIS might be causing an AEI in the vicinity of DCPP.

  16. SU-C-213-07: Fabrication and Testing of a 3D-Printed Small Animal Rectal Cooling Device to Evaluate Local Hypothermia as a Radioprotector During Prostate SBRT

    Energy Technology Data Exchange (ETDEWEB)

    Hrycushko, B; Chopra, R; Futch, C; Bing, C; Wodzak, M; Stojadinovic, S; Jiang, S; Medin, P [UT Southwestern Medical Center, Dallas, TX (United States)

    2015-06-15

    Purpose: The protective effects of induced or even accidental hypothermia on the human body are widespread with several medical uses currently under active research. In vitro experiments using human cell lines have shown hypothermia provides a radioprotective effect that becomes more pronounced at large, single-fraction doses common to SBRT treatments. Relevant to prostate SBRT, this work details the fabrication and testing of a 3D-printed cooling device to facilitate the investigation of the radioprotective effect of local hypothermia on the rat rectum. Methods: A 3cm long, two-channel rectal cooling device was designed in SOLIDWORKS CAD for 3D printing. The water intake nozzle is connected to a 1mm diameter brass pipe from which water flows and circulates back around to the exit nozzle. Both nozzles are connected by plastic tubing to a water chiller pump. Following leak-proof testing, fiber optic temperature probes were used to evaluate the temperature over time when placed adjacent to the cooling device within a rat rectum. MRI thermometry characterized the relative temperature distribution in concentric ROIs surrounding the probe. CBCT images from a small-animal irradiator were evaluated for imaging artifacts which could affect Monte Carlo dose calculations during treatment planning. Results: The rectal temperature adjacent to the cooling device decreased from body temperature (37°C) to 15°C in 10–20 minutes from device insertion. Rectal temperature was maintained at 15±3°C during active cooling. MRI thermometry tests revealed a steep temperature gradient with increasing distance from the cooling device, with the desired temperature range maintained within the surrounding few millimeters. Conclusion: A 3D printed rectal cooling device was fabricated for the purpose of inducing local hypothermia in rat rectums. Rectal cooling capabilities were characterized in-vivo to facilitate an investigation of the radioprotective effect of hypothermia for late rectal

  17. Evaluation of fuel fabrication and the back end of the fuel cycle for light-water- and heavy-water-cooled nuclear power reactors

    Energy Technology Data Exchange (ETDEWEB)

    Carter, W.L.; Olsen, A.R.

    1979-06-01

    The classification of water-cooled nuclear reactors offers a number of fuel cycles that present inherently low risk of weapons proliferation while making power available to the international community. Eight fuel cycles in light water reactor (LWR), heavy water reactor (HWR), and the spectral shift controlled reactor (SSCR) systems have been proposed to promote these objectives in the International Fuel Cycle Evaluation (INFCE) program. Each was examined in an effort to provide technical and economic data to INFCE on fuel fabrication, refabrication, and reprocessing for an initial comparison of alternate cycles. The fuel cycles include three once-through cycles that require only fresh fuel fabrication, shipping, and spent fuel storage; four cycles that utilize denatured uranium--thorium and require all recycle operations; and one cycle that considers the LWR--HWR tandem operation requiring refabrication but no reprocessing.

  18. Experimental evaluation of a breadboard heat and product-water removal system for a space-power fuel cell designed with static water removal and evaporative cooling

    Science.gov (United States)

    Hagedorn, N. H.; Prokipius, P. R.

    1977-01-01

    A test program was conducted to evaluate the design of a heat and product-water removal system to be used with fuel cell having static water removal and evaporative cooling. The program, which was conducted on a breadboard version of the system, provided a general assessment of the design in terms of operational integrity and transient stability. This assessment showed that, on the whole, the concept appears to be inherently sound but that in refining this design, several facets will require additional study. These involve interactions between pressure regulators in the pumping loop that occur when they are not correctly matched and the question of whether an ejector is necessary in the system.

  19. Evaluation of finite element formulations for transient conduction forced-convection analysis. [of heat transfer for active cooling of hypersonic airframe and engine structures

    Science.gov (United States)

    Thornton, E. A.; Wieting, A. R.

    1979-01-01

    Conventional versus upwind convective finite elements, and lumped versus consistent formulations for practical conduction/forced convection analysis are evaluated on the basis of numerical studies, with finite element and finite difference lumped-parameter temperatures compared to closed-form analytical solutions for convection problems. Attention is given to two practical combined conduction and forced convection applications, stressing that the finite element method, showing superior accuracy, is competitive with the finite difference lumped-parameter method. Also considered are the computational time savings offered by the zero capacitance nodes procedure and comparative finite element and finite difference lumped-parameter computer times. The present study has reference to the design of actively cooled engine and airframe structures for hypersonic flight.

  20. Evaluation of an Absorption Heat Pump to Mitigate Plant Capacity Reduction Due to Ambient Temperature Rise for an Air-Cooled Ammonia and Water Cycle: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Bharathan, D.; Nix, G.

    2001-08-06

    Air-cooled geothermal plants suffer substantial decreases in generating capacity at increased ambient temperatures. As the ambient temperature rises by 50 F above a design value of 50 F, at low brine-resource temperatures, the decrease in generating capacity can be more than 50%. This decrease is caused primarily by increased condenser pressure. Using mixed-working fluids has recently drawn considerable attention for use in power cycles. Such cycles are more readily amenable to use of absorption ''heat pumps.'' For a system that uses ammonia and water as the mixed-working fluid, this paper evaluates using an absorption heat pump to reduce condenser backpressure. At high ambient temperatures, part of the turbine exhaust vapor is absorbed into a circulating mixed stream in an absorber in series with the main condenser. This steam is pumped up to a higher pressure and heated to strip the excess vapor, which is recondensed using an additional air-cooled condenser. The operating conditions are chosen to reconstitute this condensate back to the same concentration as drawn from the original system. We analyzed two power plants of nominal 1-megawatt capacity. The design resource temperatures were 250 F and 300 F. Ambient temperature was allowed to rise from a design value of 50 F to 100 F. The analyses indicate that using an absorption heat pump is feasible. For the 300 F resource, an increased brine flow of 30% resulted in a net power increase of 21%. For the 250 F resource, the increase was smaller. However, these results are highly plant- and equipment-specific because evaluations must be carried out at off-design conditions for the condenser. Such studies should be carried out for specific power plants that suffer most from increased ambient temperatures.

  1. MULTIFUNCTIONAL SOLAR SYSTEMS FOR HEATING AND COOLING

    Directory of Open Access Journals (Sweden)

    Doroshenko A.V.

    2010-12-01

    Full Text Available The basic circuits of multifunctional solar systems of air drainage, heating (hot water supply and heating, cooling and air conditioning are developed on the basis of open absorption cycle with a direct absorbent regeneration. Basic decisions for new generation of gas-liquid solar collectors are developed. Heat-mass-transfer apparatus included in evaporative cooling system, are based on film interaction of flows of gas and liquid and in them, for the creation of nozzle, multi-channel structures from polymeric materials and porous ceramics are used. Preliminary analysis of multifunctional systems possibilities is implemented.

  2. Evaluation of Liquid-Based Swab Transport Systems against the New Approved CLSI M40-A2 Standard.

    Science.gov (United States)

    Gizzie, Nina; Adukwu, Emmanuel

    2016-04-01

    Following revised information pertaining to newer swab types and testing protocols in the new CLSI M40-A2 standard, we evaluated three liquid swab transport systems for the recovery of aerobic, anaerobic, and fastidious organisms at room temperature and at 4°C. All tested liquid swab transport systems were fully compliant with the M40-A2 standard, with acceptable performance at both temperatures after the full specified holding period, using both qualitative (roll-plate) and quantitative (swab elution) methods. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  3. Evaluation of coverage, retention patterns and selectivity of seven liquid chromatographic methods for metabolomics

    OpenAIRE

    Wernisch, Stefanie; Pennathur, Subramaniam

    2016-01-01

    Liquid chromatography-mass spectrometry (LC-MS)-based metabolomics studies require highly selective and efficient chromatographic techniques. Typically employed reversed-phase (RP) methods fail to target polar metabolites but the introduction of hydrophilic interaction liquid chromatography (HILIC) is slow due to perceived issues of reproducibility and ruggedness and a limited understanding of the complex retention mechanisms.

  4. Laboratory evaluation of thermal protective clothing performance upon hot liquid splash.

    Science.gov (United States)

    Gholamreza, Farzan; Song, Guowen

    2013-07-01

    This study provides an understanding of heat and mass transfer through materials exposed to hot liquid splash, a relatively unexplored hazard in the safety clothing industry. Selected fabrics and layered systems were exposed to three hot liquids to study the effects of hot liquids and configuration. To explore the energy transfer mechanisms, a modified apparatus (based on ASTM F 2701-08) was developed to assess the protection performance provided by a fabric when exposed to a hot liquid. The modified test method allows measurement of the energy absorbed by the sensor, and with the use of a skin model, the time required to produce a second-degree burn injury was predicted. The preliminary testing demonstrated that mass transfer of the hot liquid through the fabric is the main factor contributing to burn injury. Key factors that determine the level of protection that a fabric system provides are summarized.

  5. Evaluation of a New Automated Processing System (TACAS™ Pro) for Liquid-Based Procedures.

    Science.gov (United States)

    Kuramoto, Hiroyuki; Sugimoto, Naoko; Iwami, Yoshiko; Kato, Chizuyo; Hori, Masuko; Iida, Manichi

    2015-01-01

    To evaluate a fully automated processing system (TACAS™ Pro) for liquid-based procedures (LBPs). Materials were 3,483 and additionally 502 specimens that were taken at Kanagawa Health Service Association. Specimens obtained with a Cervex-Brush® were first smeared to glass slides using one side of the brush and then processed to TACAS Pro. (1) The microscopy watching time per normal case was 3.65 ± 0.85 min in the conventional procedure, whereas in the LBP it was 1.95 ± 0.60 min, and the latter reduced workload to 53%. (2) The handling time of TACAS Pro per day was 2 h and 25.8 min. The workload at a laboratory offset it and revealed the work saving to be 63.8%. (3) Unsatisfactory rates were 0% in the conventional procedure, whereas in the LBP it was 1.88% at first. The latter rate decreased to 0.5% after system improvement. (4) Specimens which may disturb microscopy analysis were found in 1.06%, including 3 cases of possible carry-over of cells to the following slides. An additional study with the revised system confirmed no carry-over. (5) Incidences of abnormal cytology were consistent between the two methods. The revised automated processing system TACAS Pro is a feasible and useful LBP and reduces the workload of cytology laboratories. © 2015 S. Karger AG, Basel.

  6. Evaluation of the sorption mechanism of ionic liquids onto multi-walled carbon nanotubes.

    Science.gov (United States)

    Wojsławski, Jerzy; Białk-Bielińska, Anna; Paszkiewicz, Monika; Toński, Michał; Stepnowski, Piotr; Dołżonek, Joanna

    2018-01-01

    The knowledge of the sorption mechanism of different chemicals onto third generation carbon sorbents such as carbon nanotubes (CNTs) is needed in order to project systems for the effective removal of pollutants from the environment. This paper reports evaluation of the sorption mechanism of selected ionic liquids (ILs), being considered as potential pollutant in environment, onto various CNTs. CNTs characterized by the smallest diameter and the biggest surface area showed the highest sorption capacity to isolate ILs from an aqueous solution. CNTs with a bigger diameter, a functionalized surface and particularly a helical shape showed a lower sorption capacity. The sorption mechanism has been defined as complex, including van der Waals, π-π and electrostatic interactions with dominating π-π interactions. Due to the relatively high sorption coefficient (355.98 ± 20.69-6397.10 ± 355.42 L kg-1 depending on the IL) the study showed that multi-walled carbon nanotubes can potentially be used to effectively isolate ILs from an aqueous solution. Moreover, proved in this study, the fast sorption kinetic, and uncomplicated regeneration process, leading to an even higher sorption capacity, means that CNTs are promising material which could find potential applications in the treatment of water contaminated by ILs. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Environmental Impact of Ionic Liquids: Automated Evaluation of the Chemical Oxygen Demand of Photochemically Degraded Compounds.

    Science.gov (United States)

    Costa, Susana P F; Pereira, Sarah A P; Pinto, Paula C A G; Araujo, André R T S; Passos, Marieta L C; Saraiva, M Lúcia M F S

    2017-05-19

    A novel automated fluorimetric technique was developed for the assessment of the chemical oxygen demand (COD) of ionic liquids (ILs) and combined with a photodegradation step to promote IL degradation. The method was implemented on a sequential injection analysis (SIA) system and is based on the reduction of cerium(IV) in the presence of irradiated ILs. Compounds incorporating the chloride anion were found to exhibit higher COD values and 1-butyl-3-methylimidazolium chloride ([bmim]+ [Cl]- ), 1-butyl-1-methylpyrrolidinium chloride ([bmpyr]+ [Cl]- ), and1-hexyl-3-methylimidazolium chloride ([hmim]+ [Cl]- ) also exhibited considerable photodegradability, whereas the cholinium cation and methanesulfonate and tetrafluoroborate anions showed resistance to photolysis. The developed methodology proved to be a simple, affordable, and robust method, showing good repeatability under the tested conditions (rsd evaluation of compounds' potential impact in the aquatic field. Additionally, the photolysis step presents an attractive option to promote degradation of ILs prior to their release into wastewater. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Hydrogeologic Evaluation of a Ground-Source Cooling System at the BSF/CSF on the Battelle Campus: Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Freedman, Vicky L.; Mackley, Rob D.; Waichler, Scott R.; Horner, Jacob A.; Moon, Thomas W.; Newcomer, Darrell R.; DeSmet, Darrell J.; Lindsey, K. A.; Porcello, J. J.

    2010-05-12

    conductivity estimates for the Ringold Formation. Two different operational scenarios were simulated using conservative assumptions, such as the absence of river water intrusion in the near shore groundwater. When seasonal injection of warm and cool water occurred, temperature impacts were insignificant at the Columbia River (< +0.2ºC), irrespective of the hydraulic conductivity estimate. The second operational scenario simulated continuous heat rejection, a condition anticipated once the BSF/CSF is fully loaded with laboratory and computer equipment. For the continuous heat rejection case, where hourly peak conditions were simulated as month-long peaks, the maximum change in temperature along the shoreline was ~1ºC. If this were to be interpreted as an absolute change in a static river temperature, it could be considered significant. However, the warmer-than-ambient groundwater flux that would potentially discharge to the Columbia River is very small relative to the flow in the river. For temperatures greater than 17.0ºC, the flow relative to a low-flow condition in the river is only 0.012%. Moreover, field data has shown that diurnal fluctuations in temperature are as high as 5ºC along the shoreline.

  9. Laser-induced thermotherapy for lung tissue--evaluation of two different internally cooled application systems for clinical use.

    Science.gov (United States)

    Ritz, Joerg P; Lehmann, Kai S; Mols, Anke; Frericks, Bernd; Knappe, Verena; Buhr, Heinz J; Holmer, Christoph

    2008-04-01

    carbonizations only started to occur at 28 W (33,600 J). Under in vivo conditions, all pigs tolerated the LITT procedure well without complications. Besides a typical cooling effect in the vicinity of blood vessels, the thermal lesions were about three times smaller than the ex vivo lesions. Both the percutaneous and the open LITT application system induced reproducible, clinically relevant lung lesions. The percutaneous puncture set generated large relevant lesions, although its usability is limited by its restricted capacity and high carbonization risk. It is suitable for powers up to 22 W. The intraoperative application system allows higher energy exposure to induce larger lesion volumes. This study elucidates the dose-effect relation of two clinically relevant puncture sets.

  10. Performance Evaluation of a High Bandwidth Liquid Fuel Modulation Valve for Active Combustion Control

    Science.gov (United States)

    Saus, Joseph R.; DeLaat, John C.; Chang, Clarence T.; Vrnak, Daniel R.

    2012-01-01

    At the NASA Glenn Research Center, a characterization rig was designed and constructed for the purpose of evaluating high bandwidth liquid fuel modulation devices to determine their suitability for active combustion control research. Incorporated into the rig s design are features that approximate conditions similar to those that would be encountered by a candidate device if it were installed on an actual combustion research rig. The characterized dynamic performance measures obtained through testing in the rig are planned to be accurate indicators of expected performance in an actual combustion testing environment. To evaluate how well the characterization rig predicts fuel modulator dynamic performance, characterization rig data was compared with performance data for a fuel modulator candidate when the candidate was in operation during combustion testing. Specifically, the nominal and off-nominal performance data for a magnetostrictive-actuated proportional fuel modulation valve is described. Valve performance data were collected with the characterization rig configured to emulate two different combustion rig fuel feed systems. Fuel mass flows and pressures, fuel feed line lengths, and fuel injector orifice size was approximated in the characterization rig. Valve performance data were also collected with the valve modulating the fuel into the two combustor rigs. Comparison of the predicted and actual valve performance data show that when the valve is operated near its design condition the characterization rig can appropriately predict the installed performance of the valve. Improvements to the characterization rig and accompanying modeling activities are underway to more accurately predict performance, especially for the devices under development to modulate fuel into the much smaller fuel injectors anticipated in future lean-burning low-emissions aircraft engine combustors.

  11. Three-dimensional evaluation of postoperative swelling in treatment of zygomatic bone fractures using two different cooling therapy methods: a randomized, observer-blind, prospective study.

    Science.gov (United States)

    Modabber, Ali; Rana, Madiha; Ghassemi, Alireza; Gerressen, Marcus; Gellrich, Nils-Claudius; Hölzle, Frank; Rana, Majeed

    2013-07-29

    Surgical treatment and complications in patients with zygomatic bone fractures can lead to a significant degree of tissue trauma resulting in common postoperative symptoms and types of pain, facial swelling and functional impairment. Beneficial effects of local cold treatment on postoperative swelling, edema, pain, inflammation, and hemorrhage, as well as the reduction of metabolism, bleeding and hematomas, have been described.The aim of this study was to compare postoperative cooling therapy applied through the use of cooling compresses with the water-circulating cooling face mask manufactured by Hilotherm in terms of beneficial impact on postoperative facial swelling, pain, eye motility, diplopia, neurological complaints and patient satisfaction. Forty-two patients were selected for treatment of unilateral zygomatic bone fractures and were divided randomly to one of two treatments: either a Hilotherm cooling face mask or conventional cooling compresses. Cooling was initiated as soon as possible after surgery until postoperative day 3 and was applied continuously for 12 hours daily. Facial swelling was quantified through a three-dimensional optical scanning technique. Furthermore, pain, neurological complaints, eye motility, diplopia and patient satisfaction were observed for each patient. Patients receiving a cooling therapy by Hilotherm demonstrated significantly less facial swelling, less pain, reduced limitation of eye motility and diplopia, fewer neurological complaints and were more satisfied compared to patients receiving conventional cooling therapy. Hilotherapy is more efficient in managing postoperative swelling and pain after treatment of unilateral zygomatic bone fractures than conventional cooling. German Clinical Trials Register ID: DRKS00004846.

  12. Performance and evaluation of gas-engine-driven split-system cooling equipment at the Willow Grove Naval Air Station

    Energy Technology Data Exchange (ETDEWEB)

    Armstrong, P.R.; Schmelzer, J.R.

    1997-01-01

    DOE`s Federal Energy Management Program supports efforts to reduce energy use and associated expenditures within the federal sector; one such effort, the New Technology Demonstration Program (NTDP)(formerly the Test Bed Demonstration program), seeks to evaluate new energy saving US technologies and secure their more timely adoption by the federal government. This report describes the field evaluation conducted to examine the performance of a 15-ton natural-gas-engine- driven, split-system, air-conditioning unit. The unit was installed at a multiple-use building at Willow Grove Naval Air Station, a regular and reserve training facility north of Philadelphia, and its performance was monitored under the NTDP.

  13. Design and demonstration of heat pipe cooling for NASP and evaluation of heating methods at high heating rates

    Energy Technology Data Exchange (ETDEWEB)

    Merrigan, M.A.; Sena, J.T.

    1989-01-01

    An evaluation of two heating methods for demonstration of NASP leading edge heat pipe technology was conducted. The heating methods were and rf induction heated plasma jet and direct rf induction. Tests were conducted to determine coupling from the argon plasma jet on a surface physically similar to a heat pipe. A molybdenum tipped calorimeter was fabricated and installed in an rf induction heated plasma jet for the test. The calorimetric measurements indicated a maximum power coupling of approximately 500 W/cm{sup 2} with the rf plasma jet. The effect of change in gas composition on the heating rate was investigated using helium. An alternative to the plasma heating of a heat pipe tip, an rf concentrator was evaluated for coupling to the hemispherical tip of a heat pipe. A refractory metal heat pipe was designed, fabricated, and tested for the evaluation. The heat pipe was designed for operation at 1400 to 1900 K with power input to 1000 W/cm{sup 2} over a hemispherical nose tip. Power input of 800 W/cm{sup 2} was demonstrated using the rf concentrator. 2 refs., 13 figs.

  14. The MICE Demonstration of Muon Ionization Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Lagrange, Jean-Baptiste [Imperial Coll., London; Hunt, Christopher [Imperial Coll., London; Palladino, Vittorio [INFN, Naples; Pasternak, Jaroslaw [Imperial Coll., London

    2016-06-01

    Muon beams of low emittance provide the basis for the intense, well-characterised neutrino beams necessary to elucidate the physics of flavour at the Neutrino Factory and to provide lepton-antilepton collisions up to several TeV at the Muon Collider. The international Muon Ionization Cooling Experiment (MICE) will demonstrate muon ionization cooling, the technique proposed to reduce the phase-space volume occupied by the muon beam at such facilities. In an ionization-cooling channel, the muon beam traverses a material (the absorber) loosing energy, which is replaced using RF cavities. The combined effect is to reduce the transverse emittance of the beam (transverse cooling). The configuration of MICE required to deliver the demonstration of ionization cooling is being prepared in parallel to the execution of a programme designed to measure the cooling properties of liquid-hydrogen and lithium hydride. The design of the cooling-demonstration experiment will be presented together with a summary of the performance of each of its components and the cooling performance of the experiment.

  15. Evaluation of transfer rates of multiple pesticides from green tea into infusion using water as pressurized liquid extraction solvent and ultra-performance liquid chromatography tandem mass spectrometry.

    Science.gov (United States)

    Chen, Hongping; Pan, Meiling; Liu, Xin; Lu, Chengyin

    2017-02-01

    Pesticide residues could be transferred from tea into its infusion and by-products, and subsequently consumed by humans. Extra extraction conditions may induce more pesticide leaching into the infusion and by-products of tea and cause greater damage to humans. The aim of this study is to evaluate the infusion of multiple pesticides from green tea into hot water via pressurized liquid extraction. The results showed that pesticides in spiked samples generally have higher leaching (0.8-45.0%) than those in the positive samples. There was a marked rise of transfer rates when water solubility increased from 20mgL(-1) to 450mgL(-1) and LogKow decreased from 6 to 4. All pesticides had more leaching into hot water using pressurized liquid extraction than traditional tea brewing. This study helps in risk assessment of pesticide residues and in the formulation of maximum residue levels (MRLs) in tea and its by-products. Copyright © 2016 Elsevier Ltd. All rights reserved.

  16. Restaurant Food Cooling Practices†

    Science.gov (United States)

    BROWN, LAURA GREEN; RIPLEY, DANNY; BLADE, HENRY; REIMANN, DAVE; EVERSTINE, KAREN; NICHOLAS, DAVE; EGAN, JESSICA; KOKTAVY, NICOLE; QUILLIAM, DANIELA N.

    2017-01-01

    Improper food cooling practices are a significant cause of foodborne illness, yet little is known about restaurant food cooling practices. This study was conducted to examine food cooling practices in restaurants. Specifically, the study assesses the frequency with which restaurants meet U.S. Food and Drug Administration (FDA) recommendations aimed at reducing pathogen proliferation during food cooling. Members of the Centers for Disease Control and Prevention’s Environmental Health Specialists Network collected data on food cooling practices in 420 restaurants. The data collected indicate that many restaurants are not meeting FDA recommendations concerning cooling. Although most restaurant kitchen managers report that they have formal cooling processes (86%) and provide training to food workers on proper cooling (91%), many managers said that they do not have tested and verified cooling processes (39%), do not monitor time or temperature during cooling processes (41%), or do not calibrate thermometers used for monitoring temperatures (15%). Indeed, 86% of managers reported cooling processes that did not incorporate all FDA-recommended components. Additionally, restaurants do not always follow recommendations concerning specific cooling methods, such as refrigerating cooling food at shallow depths, ventilating cooling food, providing open-air space around the tops and sides of cooling food containers, and refraining from stacking cooling food containers on top of each other. Data from this study could be used by food safety programs and the restaurant industry to target training and intervention efforts concerning cooling practices. These efforts should focus on the most frequent poor cooling practices, as identified by this study. PMID:23212014

  17. Flat structure cooled detector assembly

    Science.gov (United States)

    Reeb, Nathalie; Coutures, Bernard; Gerin, Nicolas; Reale, S.; Guille, B.

    1994-07-01

    Long wavelength IR detectors need to be cooled at cryogenic temperature to achieve high performances. This specific need makes it difficult to integrate the detector because of high cost of dewar and cooling device designed to fulfill severe vibration conditions. A new era for IR detection could begin with flat structures allowing intrinsic vibration resistance for detectors to be plugged on electronics board. Sofradir has carried out a study about feasibility of detector dewar assembly including a flat Joule-Thomson cooler with porous heat exchanger in cooperation with Air Liquide. The aim of this paper is to put forward the interest of such a product. The very good results achieved demonstrate a promising future for such flat structure detector assembly.

  18. Evaluation of the Initial Isothermal Physics Measurements at the Fast Flux Test Facility, a Prototypic Liquid Metal Fast Breeder Reactor

    Energy Technology Data Exchange (ETDEWEB)

    John D. Bess

    2010-03-01

    The Fast Flux Test Facility (FFTF) was a 400-MWt, sodium-cooled, low-pressure, high-temperature, fast-neutron flux, nuclear fission reactor plant designed for the irradiation testing of nuclear reactor fuels and materials for the development of liquid metal fast breeder reactors (LMFBRs). The FFTF was fueled with plutonium-uranium mixed oxide (MOX) and reflected by Inconel-600. Westinghouse Hanford Company operated the FFTF as part of the Hanford Engineering Development Laboratory (HEDL) for the U.S. Department of Energy on the Hanford Site near Richland, Washington. Although the FFTF was a testing facility not specifically designed to breed fuel or produce electricity, it did provide valuable information for LMFBR projects and base technology programs in the areas of plant system and component design, component fabrication, prototype testing, and site construction. The major objectives of the FFTF were to provide a strong, disciplined engineering base for the LMFBR program, provide fast flux testing for other U.S. programs, and contribute to the development of a viable self-sustaining competitive U.S. LMFBR industry. During its ten years of operation, the FFTF acted as a national research facility to test advanced nuclear fuels, materials, components, systems, nuclear power plant operating and maintenance procedures, and active and passive reactor safety technologies; it also produced a large number of isotopes for medical and industrial users, generated tritium for the U.S. fusion research program, and participated in cooperative, international research work. Prior to the implementation of the reactor characterization program, a series of isothermal physics measurements were performed; this acceptance testing program consisted of a series of control rod worths, critical rod positions, subcriticality measurements, maximum reactivity addition rates, shutdown margins, excess reactivity, and isothermal temperature coefficient reactivity. The results of these

  19. SEPARATE DIGESTION OF LIQUID AND SOLID FRACTIONS OF THERMALLY PRETREATED SECONDARY SLUDGE. ASSESSMENT AND GLOBAL EVALUATION

    Directory of Open Access Journals (Sweden)

    S. I. Pérez-Elvira

    Full Text Available Abstract The fractioning into separate liquid and solid fractions obtained by centrifugation of thickened fresh and thermally pretreated (170 ºC, 50 minutes secondary sludge showed that 30% of the particulate organic matter was released during the pretreatment, correspondingly increasing the methane production of the particulate matter by 30% (from 259 to 329 mL CH4/g VSfed. The responsible of this enhancement was the liquid fraction, as the biodegradability of the solid fraction remained constant after the pretreatment. Mass balances showed that 34% of the VS were released to the liquid fraction, generating nearly 50% of the total methane produced, with much faster kinetics compared to the solid fraction. These results support the hypothesis of a separate liquid-solid digestion of thermally pretreated sludge, which would result in decreasing the digestion volume to half while duplicating the methane productivity per kilogram of sludge fed to digestion.

  20. Scale-up and evaluation of high solid ionic liquid pretreatment and enzymatic hydrolysis of switchgrass

    National Research Council Canada - National Science Library

    Li, Chenlin; Tanjore, Deepti; He, Wei; Wong, Jessica; Gardner, James L; Sale, Kenneth L; Simmons, Blake A; Singh, Seema

    2013-01-01

    Ionic liquid (IL) pretreatment is receiving significant attention as a potential process that enables fractionation of lignocellulosic biomass and produces high yields of fermentable sugars suitable for the production of renewable fuels...

  1. Transmission-lattice based geometric phase analysis for evaluating the dynamic deformation of a liquid surface.

    Science.gov (United States)

    Shi, Wenxiong; Huang, Xianfu; Liu, Zhanwei

    2014-05-05

    Quantitatively measuring a dynamic liquid surface often presents a challenge due to high transparency, fluidity and specular reflection. Here, a novel Transmission-Lattice based Geometric Phase Analysis (TLGPA) method is introduced. In this method, a special lattice is placed underneath a liquid to be tested and, when viewed from above, the phase of the transmission-lattice image is modulated by the deformation of the liquid surface. Combining this with multi-directional Newton iteration algorithms, the dynamic deformation field of the liquid surface can be calculated from the phase variation of a series of transmission-lattice images captured at different moments. The developed method has the advantage of strong self-adaption ability to initial lattice rotational errors and this is discussed in detail. Dynamic 3D ripples formation and propagation was investigated and the results obtained demonstrated the feasibility of the method.

  2. Toxicological evaluation of a novel cooling compound: 2-(4-methylphenoxy)-N-(1H-pyrazol-3-yl)-N-(2-thienylmethyl)acetamide.

    Science.gov (United States)

    Karanewsky, Donald S; Arthur, Amy J; Liu, Hanghui; Chi, Bert; Markison, Stacy

    2015-01-01

    A toxicological evaluation of a novel cooling agent, 2-(4-methylphenoxy)- N -(1 H -pyrazol-3-yl)- N -(2-thienylmethyl) acetamide (S2227; CAS 1374760-95-8), was completed for the purpose of assessing its safety for use in food and beverage applications. S2227 undergoes rapid oxidative metabolism in vitro , and in rat and dog pharmacokinetic studies is rapidly converted to its component carboxylic acid and secondary amine. S2227 was not found to be mutagenic or clastogenic in vitro , and did not induce micronuclei in polychromatic erythrocytes in vivo . The secondary amine hydrolysis product, N -(2-thienylmethyl)-1 H -pyrazol-3-amine (M179), was also evaluated for genotoxicity. In subchronic oral toxicity studies in rats, the no-observed-adverse-effect-level (NOAEL) for S2227 was 100 mg/kg/day (highest dose tested) when administered by oral gavage for 90 consecutive days. Furthermore, S2227 demonstrated a lack of maternal toxicity, as well as adverse effects on fetal morphology at the highest dose tested, providing a NOAEL of 1000 mg/kg/day for both maternal toxicity and embryo/fetal development when administered orally during gestation to pregnant rats.

  3. Evaluation of ionic liquid epoxy carbon fiber composites in a cryogenic environment

    Science.gov (United States)

    Lyne, Christopher T.; Henry, Christopher R.; Kaukler, William F.; Grugel, R. N.

    2018-03-01

    A novel ionic liquid epoxy (ILE) was used to fabricate carbon fiber composite discs which were then subjected to biaxial strain testing in liquid nitrogen. The ILE composite showed a greater strain-to-failure at cryogenic temperatures when compared to a commercial epoxy. This result is likely an effect, as shown in micrographs, of the strong ILE bonding with the carbon fibers as well as it exhibiting plastic deformation at the fracture surface.

  4. Adiabatic Cooling of Antiprotons

    CERN Document Server

    Gabrielse, G; McConnell, R; Richerme, P; Kalra, R; Novitski, E; Grzonka, D; Oelert, W; Sefzick, T; Zielinski, M; Fitzakerley, D; George, M C; Hessels, E A; Storry, C H; Weel, M; Mullers, A; Walz, J

    2011-01-01

    Adiabatic cooling is shown to be a simple and effective method to cool many charged particles in a trap to very low temperatures. Up to 3 x 10(6) (p) over bar are cooled to 3.5 K-10(3) times more cold (p) over bar and a 3 times lower (p) over bar temperature than previously reported. A second cooling method cools (p) over bar plasmas via the synchrotron radiation of embedded (p) over bar (with many fewer (p) over bar than (p) over bar) in preparation for adiabatic cooling. No (p) over bar are lost during either process-a significant advantage for rare particles.

  5. Development and Evaluation of Liquid and Solid Self-Emulsifying Drug Delivery Systems for Atorvastatin

    Directory of Open Access Journals (Sweden)

    Anna Czajkowska-Kośnik

    2015-11-01

    Full Text Available The objective of this work was to design and characterize liquid and solid self-emulsifying drug delivery systems (SEDDS for poorly soluble atorvastatin. To optimize the composition of liquid atorvastatin-SEDDS, solubility tests, pseudoternary phase diagrams, emulsification studies and other in vitro examinations (thermodynamic stability, droplet size and zeta potential analysis were performed. Due to the disadvantages of liquid SEDDS (few choices for dosage forms, low stability and portability during the manufacturing process, attempts were also made to obtain solid SEDDS. Solid SEDDS were successfully obtained using the spray drying technique from two optimized liquid formulations, CF3 and OF2. Despite liquid SEDDS formulation, CF3 was characterized by lower turbidity, higher percentage transmittance and better self-emulsifying properties, and based on the in vitro dissolution study it can be concluded that better solubilization properties were exhibited by solid formulation OF2. Overall, the studies demonstrated the possibility of formulating liquid and solid SEEDS as promising carriers of atorvastatin. SEDDS, with their unique solubilization properties, provide the opportunity to deliver lipophilic drugs to the gastrointestinal tract in a solubilized state, avoiding dissolution—a restricting factor in absorption rate of BCS Class 2 drugs, including atorvastatin.

  6. Evaluation of a liquid embolization agent (Onyx) for transcatheter embolization for renal vascular lesions

    Energy Technology Data Exchange (ETDEWEB)

    Rennert, Janine; Herold, T.; Schreyer, A.G.; Jung, E.M.; Mueller-Wille, R.; Zorger, N. [Inst. fuer Roentgendiagnostik, Klinikum der Univ. Regensburg (Germany); Banas, B.; Feuerbach, S. [Medizinische Klinik, Nephrologie, Univ. Regensburg (Germany); Lenhart, M. [Klinik fuer Diagnostische und Interventionelle Radiologie, Sozialstiftung Bamberg (Germany)

    2009-10-15

    Purpose: to evaluate the therapeutic outcome after endovascular treatment of renal vascular lesions using the liquid embolization agent, Onyx. Materials and methods: between 2004 and 2008 nine patients with renal vascular lesions were treated with transcatheter arterial embolization using Onyx. The renal vascular lesions consisted of 4 AV-fistulas, a pseudoaneurysm, bleeding from a single subsegmental artery, diffuse parenchymal bleeding after trauma, septic embolizations and multiple aneurysms in endocarditis. All patients underwent selective angiography of the renal artery. A dimethyl sulfoxide (DMSO)-compatible microcatheter was used and Onyx was injected. The technical and clinical success rate, examination time and procedure-related complications were documented. Results: the overall technical and clinical success rate was 100%. One patient had to be treated twice due to recurrent bleeding after an accidental puncture with a drainage catheter. No loss of viable renal tissue occurred in 4 cases. In 4 patients mild to moderate parenchyma loss was noted. In one patient having diffuse renal bleeding, occlusion of the main renal artery was performed. No procedure-related complications were noted. The mean examination time was 16.17 min when treating with Onyx alone and 60 min when using a combination of Onyx and coils. Within an average follow-up period of 21 months, no recurrent renal bleeding or recurrent AV-fistulas occurred. Conclusion: Onyx is an effective embolization agent for the treatment of renal vascular lesions. It allows controlled and quick application with low complication rates and a short examination time as a standalone agent or in combination with coils. (orig.)

  7. Use of fluorocarbons in the cooling of LHC experiments

    CERN Document Server

    Pimenta dos Santos, M

    2003-01-01

    Perfluorochemicals sold by 3M under the trade name 3M Fluorinert Electronic Liquids have been used for many years as heat transfer media in a variety of industries. The suitability of these liquids for the cooling of LHC experiment originates from their high dielectric strength as well as from their chemical stability under ionizing radiation. The Fluorinerts are clear, colorless, non-flammable with low toxicity and low corrosiveness. Additionally, they offer low global waming potential – GWP – and zero ozone-depletion potential – ODP. Some examples of fluorinert application in the cooling of LHC experiments will be presented : (a) the ATLAS Inner detector C3F8 evaporative cooling system (b) the ATLAS TRF C6F14 monophase cooling system and (c) the ALICE SPD “active heat pipe” C4F10 evaporative cooling system. A brief comparison of evaporative and monophase cooling systems will be outlined.

  8. Advanced Gas Cooled Nuclear Reactor Materials Evaluation and Development Program. Quarterly progress report, April 1, 1977--June 30, 1977

    Energy Technology Data Exchange (ETDEWEB)

    1977-01-01

    The objectives of this program are to evaluate candidate alloys of Very High Temperature Reactor (VHTR) Process Heat and Direct Cycle helium Turbine (DCHT) applications, in terms of the effects of simulated reactor primary coolant (impure helium), high temperatures, and long time exposures on the mechanical properties and structural and surface stability of selected candidate alloys. A second objective is to select and recommend materials for future test facilities and more extensive qualification programs. Work covered in the report includes completion of alloy selection for the screening tests. The alloys selected for potential VHTR Nuclear Process Heat (NPH) applications and for potential DCHT applications are listed. The present status on the simulated reactor helium loop design and construction and the design and construction progress on the testing and analysis facilities and equipment are discussed.

  9. Advanced gas cooled nuclear reactor materials evaluation and development program. Progress report, April 1--June 30, 1978

    Energy Technology Data Exchange (ETDEWEB)

    1978-08-31

    The objectives of the program are to evaluate candidate alloys for Very High Temperature Reactor Nuclear Process Heat (NPH) and Direct Cycle Helium Turbine (DCHT) applications, in terms of the affect of simulated reactor primary coolant (Helium containing small amounts of various other gases), high temperatures, and long time exposures, on the mechanical properties and structural and surface stability of selected candidate alloys. A second objective is to select and recommend materials for future test facilities and more extensive qualification programs. Work covered in the report includes the activities associated with the procurement of the materials for the screening test program, information from vendor certification for the materials receiver, and preliminary information from the materials characterization tests performed by General Electric. The construction status of the simulated reactor helium supply system, testing equipment, and gas chemistry analysis instrumentation and equipment are discussed. The status of the data management system is also reviewed.

  10. The ATLAS LARG ROD G-Links Cooling System

    CERN Document Server

    Hubaut, F; Repain, P; Rossel, F; Vincent, D

    2004-01-01

    In this note is described the water cooling system that will be implemented on the ROD boards of the liquid argon calorimeter detectors in order to guarantee a proper behavior of the optical reception of the data.

  11. LOX/Methane Regeneratively-Cooled Rocket Engine Development Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Design, build, and test a 5,000 lbf thrust regeneratively cooled combustion chamber at JSC for a low pressure liquid oxygen/methane engine. The engine demonstrates...

  12. Advanced Gas Cooled Nuclear Reactor Materials Evaluation and Development Program. Progress report, July 1, 1980-September 30, 1980

    Energy Technology Data Exchange (ETDEWEB)

    1980-12-12

    Objectives of this program are to evaluate candidate alloys for Very High Temperature Reactor (VHTR) Nuclear Process Heat (NPH) and Direct Cycle Helium Turbine (DCHT) applications, in terms of the effect of simulated reactor primary coolant (helium containing small amounts of various other gases), high temperatures, and long time exposures, on the mechanical properties and structural and surface stability of selected candidate alloys. A second objective is to select and recommend materials for future test facilities and more extensive qualification programs. Work covered in this report includes the activities associated with the status of the simulated reactor helium supply system, testing equipment and gas chemistry analysis instrumentation and equipment. The progress in the screening test program is described: screening creep results and metallographic analysis for materials thermally exposed or tested at 750, 850, 950 and 1050/sup 0/C. Initiation of controlled purity helium creep-rupture testing in the intensive screening test program is discussed. In addition, the results of 1000-hour exposures at 750 and 850/sup 0/C on several experimental alloys are discussed.

  13. Advanced Gas Cooled Nuclear Reactor Materials Evaluation and Development Program. Progress report, April 1, 1980-June 30, 1980

    Energy Technology Data Exchange (ETDEWEB)

    1980-11-14

    Objectives of this program are to evaluate candidate alloys for Very High Temperature Reactor (VHTR) Nuclear Process Heat (NPH) and Direct Cycle Helium Turbine (DCHT) applications, in terms of the effect of simulated reactor primary coolant (helium containing small amounts of various other gases), high temperatures, and long time exposures, on the mechanical properties and structural and surface stability of selected candidate alloys. A second objective is to select and recommend materials for future test facilities and more extensive qualification programs. Work covered in this report includes the activities associated with the status of the simulated reactor helium supply system, testing equipment and gas chemistry analysis instrumentation and equipment. The progress in the screening test program is described; this includes: screening creep results and metallographic analysis for materials thermally exposed or tested at 750, 850 and 950/sup 0/C. The initiation of air creep-rupture testing in the intensive screening test program is discussed. In addition, the status of the data management system is described.

  14. Assessment of Proliferation Resistance of Closed Nuclear Fuel Cycle System with Sodium Cooled Fast Reactors Using INPRO Evaluation Methodology

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young In; Hahn, Do Hee; Won, Byung Chool; Lee, Dong Uk

    2007-11-15

    Using the INPRO methodology, the proliferation resistance of an innovative nuclear energy system(INS) defined as a closed nuclear fuel cycle system consisting of KALIMER and pyroprocessing, has been assessed. Considering a very early development stage of the INS concept, the PR assessment is carried out based on intrinsic features, if required information and data are not available. The PR assessment of KALIMER and JSFR using the INPRO methodology affirmed that an adequate proliferation resistance has been achieved in both INSs CNFC-SFR, considering the assessor's progress and maturity of design development. KALIMER and JSFR are developed or being developed conforming to the targets and criteria defined for developing Gen IV nuclear reactor system. Based on these assessment results, proliferation resistance and physical protection(PR and PP) of KALIMER and JSFR are evaluated from the viewpoint of requirements for future nuclear fuel cycle system. The envisioned INSs CNFC-SFR rely on active plutonium management based on a closed fuel cycle, in which a fissile material is recycled in an integrated fuel cycle facility within proper safeguards. There is no isolated plutonium in the closed fuel cycle. The material remains continuously in a sequence of highly radioactive matrices within inaccessible facilities. The proliferation resistance assessment should be an ongoing analysis that keeps up with the progress and maturity of the design of Gen IV SFR.

  15. Preliminary studies for the LHCb vertex detector cooling system

    CERN Document Server

    Doets, M; Ferro-Luzzi, Massimiliano

    2000-01-01

    99-046 "We present some preliminary studies for the design of a cooling system for the LHCb silicon vertex detector. We consider the case of a cooling system using CO2 in the gas-liquid mixed phase as a coolant. Based on these considerations, we sketch a possible design."

  16. Evaluation of genotoxicity of liquid effluents from gas washing systems by means of bioassay Trad-MCN

    Energy Technology Data Exchange (ETDEWEB)

    Machado, Alessandra Carla Fattori Ergesse [Centro Tecnologico da Marinha em Sao Paulo (CTMSP), SP (Brazil). Div. de Monitoracao Ambiental], E-mail: alessandra@ctmsp.mar.mil.br; Alves, Edenise Segala [Instituto de Botanica de Sao Paulo, SP (Brazil). Secao de Anatomia], E-mail: ealves@ibot.sp.gov.br

    2007-07-01

    In the gas washing systems the gaseous emissions from a facility are forced through an absorbing liquid preventing pollutants to be dispersed into the atmosphere. In the Centro Tecnologico da Marinha em Sao Paulo/Centro Experimental Aramar (CEA), the gas washing are used to control the emissions from the uranium enrichment facilities. Uranium. fluoride, ammonia and hydrogen fluoride are the main contaminants, all heavily toxic. Biological assays, using plants or other living organisms, have been used to assess genotoxic agents in the environment. Among the bioassays using plants, the Trad-MCN has been used extensively, as it allows the evaluation of liquid or gaseous contaminants. The species Tradescantia pallida (Rose) was exposed in a dynamic system to liquid effluents from CEA. A positive control was the exposure to formaldehyde 10% in water, known as a very toxic solution, and the negative control was the exposure to filtered air. The protocol established by Ma (1983) for hybrid clones and validated for the T. pallida by Guimaraes (2003) was used to perform the Trad-MCN assays. Only preparations containing early tetrads were scored. In that context, the present study objectifies to evaluate, by the Trad-MCN bioassay, the genotoxicity of the solution from the gas washing and, also, evaluate the efficiency of that system. The results obtained show that the T. pallida is a sensitive bioindicator for the pollutants tested and can be useful for in vitro environmental monitoring under controlled conditions. (author)

  17. Liquid water infiltration into a layered snowpack: evaluation of a 3-D water transport model with laboratory experiments

    Science.gov (United States)

    Hirashima, Hiroyuki; Avanzi, Francesco; Yamaguchi, Satoru

    2017-11-01

    The heterogeneous movement of liquid water through the snowpack during precipitation and snowmelt leads to complex liquid water distributions that are important for avalanche and runoff forecasting. We reproduced the formation of capillary barriers and the development of preferential flow through snow using a three-dimensional water transport model, which was then validated using laboratory experiments of liquid water infiltration into layered, initially dry snow. Three-dimensional simulations assumed the same column shape and size, grain size, snow density, and water input rate as the laboratory experiments. Model evaluation focused on the timing of water movement, thickness of the upper layer affected by ponding, water content profiles and wet snow fraction. Simulation results showed that the model reconstructs relevant features of capillary barriers, including ponding in the upper layer, preferential infiltration far from the interface, and the timing of liquid water arrival at the snow base. In contrast, the area of preferential flow paths was usually underestimated and consequently the averaged water content in areas characterized by preferential flow paths was also underestimated. Improving the representation of preferential infiltration into initially dry snow is necessary to reproduce the transition from a dry-snow-dominant condition to a wet-snow-dominant one, especially in long-period simulations.

  18. Evaluation of energy use in district heating and cooling plant using sewage and one using air as heat source; Gesui netsuriyo chiiki reidanbo to kuki netsuriyo chiiki reidan no tonyu enerugi kaiseki

    Energy Technology Data Exchange (ETDEWEB)

    Arashi, N. [Hitachi Ltd., Tokyo (Japan). Power and Industurial Systems R and D Laboratory; Inaba, A. [National Institute for Resources and Environment, Ibaraki (Japan)

    2000-05-20

    The efficiency of energy usage of a district heating and cooling plant using sewage water as heat source and sink, was evaluated by investigating the data of the district heat demand and energy supply to the plant, which were collected at the Koraku - 1 Chome plant in Tokyo central region. Through analyzing these data, it was clarified that the overall COPs of the plant were 3.17 for cooling and 2.65 for heating. COP was then compared with that of another plant using air as heat source and sink. The overall COPs of this plant which were calculated according to the atmospheric temperature, were 2.54 for cooling in summer and 2.28 for heating in winter. The differences in COPs were due to the temperature differences between sewage water and air. As a result for COP differences, the district heating and cooling plant using sewage water could be more energy saving, up to 20 % for cooling in summer and 14 % for heating in winter, compared with the counterpart plant that uses air as heat source and sink. (author)

  19. A new thermodynamic expression for Gibbs free energy difference ΔG between the under-cooled liquid and on microstructure of near-eutectic Al-13wt%Si alloy

    Directory of Open Access Journals (Sweden)

    Xi Xiao

    2008-05-01

    Full Text Available Under cooling rates of 2 ℃/s and 10 ℃/s, the influences of B content on the microstructure of near eutectic Al-13.0wt%Si alloy have been investigated. Results showed that the addition of boron resulted in refi nement of eutectic grains, and to some extent, had an inhibiting effect on precipitation of the primary phases, and the refi ning and inhibiting effects are much more obvious at higher cooling rate. When B was not added, higher cooling rate promoted the a-Al dendrites formation. At lower cooling rate, the addition of B did not cause the so called "columnar to equiaxed transition (CET", however, at higher cooling rate, this transition was obvious. After the addition of B, the nucleation temperature TN ascended and nucleation mode changed from nucleation mode of from wall towards centre (without B addition to a nucleation mode that the eutectic nucleated evenly throughout whole sample (with B added. It can be concluded that the addition of B offers a large amount of nuclei for eutectic solidifi cation, as a result, the eutectic grains was refi ned. Higher cooling rate will lead to more nuclei, so the effects on the refi nement of eutectic grains and on suppression of primary phases are increased.

  20. Evaluation of a silicon oxynitride hydrophilic interaction liquid chromatography column in saccharide and glycoside separations.

    Science.gov (United States)

    Wan, Huihui; Sheng, Qianying; Zhong, Hongmin; Guo, Xiujie; Fu, Qing; Liu, Yanfang; Xue, Xingya; Liang, Xinmiao

    2015-05-01

    The retention characteristics of a silicon oxynitride stationary phase for carbohydrate separation were studied in hydrophilic interaction chromatography mode. Four saccharides including mono-, di-, and trisaccharides were employed to investigate the effects of water content and buffer concentration in the mobile phase on hydrophilic interaction liquid chromatography retention. For the tested saccharides, the silicon oxynitride column demonstrated excellent performance in terms of separation efficiency, hydrophilicity, and interesting separation selectivity for carbohydrates compared to the bare silica stationary phase. Finally, the silicon oxynitride hydrophilic interaction liquid chromatography column was employed in the separation of complex samples of fructooligosaccharides, saponins, and steviol glycoside from natural products. The resulting chromatograms demonstrated good separation efficiency and longer retention compared with silica, which further confirmed the advantages and potential application of silicon oxynitride stationary phase for hydrophilic interaction liquid chromatography separation. © 2015 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. CFD MODELING AND ANALYSIS FOR A-AREA AND H-AREA COOLING TOWERS

    Energy Technology Data Exchange (ETDEWEB)

    Lee, S.; Garrett, A.; Bollinger, J.

    2009-09-02

    Mechanical draft cooling towers are designed to cool process water via sensible and latent heat transfer to air. Heat and mass transfer take place simultaneously. Heat is transferred as sensible heat due to the temperature difference between liquid and gas phases, and as the latent heat of the water as it evaporates. Mass of water vapor is transferred due to the difference between the vapor pressure at the air-liquid interface and the partial pressure of water vapor in the bulk of the air. Equations to govern these phenomena are discussed here. The governing equations are solved by taking a computational fluid dynamics (CFD) approach. The purpose of the work is to develop a three-dimensional CFD model to evaluate the flow patterns inside the cooling tower cell driven by cooling fan and wind, considering the cooling fans to be on or off. Two types of the cooling towers are considered here. One is cross-flow type cooling tower located in A-Area, and the other is counterflow type cooling tower located in H-Area. The cooling tower located in A-Area is mechanical draft cooling tower (MDCT) consisting of four compartment cells as shown in Fig. 1. It is 13.7m wide, 36.8m long, and 9.4m high. Each cell has its own cooling fan and shroud without any flow communications between two adjacent cells. There are water distribution decks on both sides of the fan shroud. The deck floor has an array of about 25mm size holes through which water droplet falls into the cell region cooled by the ambient air driven by fan and wind, and it is eventually collected in basin area. As shown in Fig. 1, about 0.15-m thick drift eliminator allows ambient air to be humidified through the evaporative cooling process without entrainment of water droplets into the shroud exit. The H-Area cooling tower is about 7.3 m wide, 29.3 m long, and 9.0 m high. Each cell has its own cooling fan and shroud, but each of two corner cells has two panels to shield wind at the bottom of the cells. There is some

  2. Cooling of chiller condensers by district cooling in supermarkets; Kylning av kylmaskiners kondensorer med fjaerrkyla i livsmedelsbutiker

    Energy Technology Data Exchange (ETDEWEB)

    Haglund Stignor, Caroline [Swedish National Testing and Research Inst., Boraas (Sweden)

    2003-07-01

    Cooling of the chiller condensers in supermarkets can be performed in different ways. To start with, the condensers can be cooled by use of outdoor air in dry coolers, but the ventilation air can also perform the cooling, totally or partially. In such a way the total or a part of the heating demand of the supermarket might be covered. A third alternative for condenser cooling is use of district cooling. However, in such a case the possibility to heat the supermarket by heat recovery is lost. The purpose of this study is to outline when district cooling offers the most advantageous alternative for condenser cooling in comparison to the other alternatives. This assessment is to be performed taking costs, electricity use and environmental impact into consideration separately. The results from calculations for a case supermarket show that the price for district cooling is generally to high for making it profitable for a supermarket to cool the condensers by district cooling. However, cooling the condensers by district cooling might lead to savings for the supermarket, both in terms of investments and use of electricity. This leads to the fact that cooling the condensers by district cooling could offer a profitable alternative for the supermarket, if the prices are adapted to this type of costumer. Hopefully, such a business could be profitable for the producers of district cooling as well. In addition, there are other advantages associated with condenser cooling by district cooling, which are hard to evaluate in economic terms. When it comes to the comparison of electricity use, it is shown that condenser cooling by district cooling is the alternative that uses least electricity in a national point of view, if the district cooling is produced by a deep-water source. In this comparison, the electricity used for production of district cooling and district heating is included as well. If district cooling is co-produced with district heating in heat pumps, the result is

  3. Preparation and chromatographic evaluation of a cysteine-bonded zwitterionic hydrophilic interaction liquid chromatography stationary phase.

    Science.gov (United States)

    Shen, Aijin; Guo, Zhimou; Cai, Xiaoming; Xue, Xingya; Liang, Xinmiao

    2012-03-09

    A cysteine-bonded zwitterionic hydrophilic interaction chromatography (HILIC) stationary phase (Click TE-Cys) was prepared based on the "thiol-ene" click chemistry. The Click TE-Cys material was characterized by solid state ¹³C cross polarization/magic-angle spinning (CP/MAS) NMR and elemental analysis. The dynamic evaluation for cytosine, cytidine and orotic acid was performed using Van Deemter plots. The plate height values were no more than 24 μm for the flow rate between 0.5 and 5.4 mm s⁻¹ (0.3-3.5 mL min⁻¹), which proved the excellent separation efficiency of Click TE-Cys stationary phase. The influences of the content of water, concentration of salt and pH of the buffer solution on the retention of model compounds were investigated. The results demonstrated that the separation of polar analytes was dominated by the partitioning mechanism, while the contribution of electrostatic interaction was minor. The thermodynamic characteristic of Click TE-Cys stationary phase was also studied according to van't Hoff plot. An exothermic process for transferring analytes from the mobile phase to the stationary phase was observed and a linear relationship for ln k and 1/T was achieved, indicating no change of retention mechanism within the measured temperature range. Besides, the zwitterionic stationary phase exhibited good stability. Considering the high hydrophilicity of Click TE-Cys stationary phase, the application in the separation of protein tryptic digests was carried out using hydrophilic interaction chromatography-electrospray ionization mass spectrometry (HILIC-ESI-MS). More peaks were adequately resolved on the Click TE-Cys column comparing with that on the TSK Amide-80 column. In addition, the orthogonality between HILIC and RPLC system was investigated utilizing geometric approach. The XTerra MS C₁₈ and Click TE-Cys column displayed great difference in separation selectivity, with the orthogonality reaching 88.0%. On the other hand, the

  4. Influence of cryogenic cooling rate on mechanical properties of tool steels

    Science.gov (United States)

    Mazor, G.; Ladizhensky, I.; Shapiro, A.

    2017-09-01

    The effect of the rapid cryogenic treatment on hardness and wear resistance of several kinds of tool steel was examined. Two ways of cryogenic cooling were evaluated: direct immersion of the metallic samples into liquid nitrogen and three-stage rapid cryogenic cooling (1 - precooling in LN2 to -20°C, 2 - formation on the sample of a frost layer from air by natural humidity, 3 - second cooling of the frost-covered sample in LN2 to -195.7°C). Material in “as is” conditions and after a preliminary heat treatment (850°C) were used as the reference points. The HV microhardness and the wear rate under dry abrasive friction were evaluated. Despite the very different types of the examined metals’ nature, microstructure, and hardening mechanisms, the rapid cryogenic cooling improves both the hardness and the wear resistance values. For all investigated metals rapid cryogenic cooling assisted with the frost layer produces the best results.

  5. Cooling water distribution system

    Science.gov (United States)

    Orr, Richard

    1994-01-01

    A passive containment cooling system for a nuclear reactor containment vessel. Disclosed is a cooling water distribution system for introducing cooling water by gravity uniformly over the outer surface of a steel containment vessel using an interconnected series of radial guide elements, a plurality of circumferential collector elements and collector boxes to collect and feed the cooling water into distribution channels extending along the curved surface of the steel containment vessel. The cooling water is uniformly distributed over the curved surface by a plurality of weirs in the distribution channels.

  6. Scanning electron microscope evaluation of chlorhexidine gel and liquid associated with sodium hypochlorite cleaning on the root canal walls.

    Science.gov (United States)

    Valera, Marcia Carneiro; Chung, Adriana; Menezes, Márcia Maciel; Fernandes, Carlos Eduardo Fernandes; Carvalho, Cláudio Antonio Talge; Camargo, Samira Esteves Afonso; Camargo, Carlos Henrique Ribeiro

    2010-11-01

    The aim of this study was to evaluate, by scanning electronic microscopy (SEM), the cleaning of the root canal walls after instrumentation and irrigation with 2.5% sodium hypochlorite (NaOCl) associated with 2% chlorhexidine (CHX) gel or liquid, combined or not with 17% ethylenediamine tetra-acetic acid (EDTA). Sixty single-root human teeth were subjected to standardized root canal instrumentation with different irrigants (n = 10): G1) NaOCl + CHX liquid; G2) NaOCl + CHX liquid + EDTA + saline solution; G3) NaOCl + CHX gel; G4) NaOCl + CHX gel + EDTA + saline solution; G5) saline solution; G6) saline solution + EDTA. After instrumentation, the teeth were prepared for SEM analysis (×500 and ×2,000) to evaluate the cleaning of the cervical, middle, and apical thirds. The area analyzed was quantified according to the percentage of open and closed tubules, and data were statistically analyzed by analysis of variance and Tukey tests (P = .05). The number of open tubules was highest in G4 in all root thirds, showing statistically significant difference from G1, G2, and G5 (P < .05). G1 presented higher quantity of closed tubules significant than G2. Irrigation with NaOCl and CHX gel followed by EDTA and saline solution produced greater cleaning of the root canal walls. Copyright © 2010 Mosby, Inc. All rights reserved.

  7. Evaluating Ionic Liquids as Hypergolic Fuels: Exploring Reactivity from Molecular Structure

    Science.gov (United States)

    2014-01-27

    and n- octane . Samples were weighed and sealed in aluminum pans (5–15 mg) and heated at a rate of 5 o C/min to 100 o C. Following the initial...Ignition: An Informal History of Liquid Rocket Propellants, Rutgers University Press: New Brunswick, NJ, 1972. DISTRIBUTION A: Approved for public

  8. Evaluation of methods describing the flow of gas-liquid mixture in wells

    Energy Technology Data Exchange (ETDEWEB)

    Salim, P.H.; Stanislav, J.F. (Calgary Univ., AB (Canada))

    1994-02-01

    The simulataneous gas-liquid flow in pipes is of interest to petroleum, chemical and nuclear industries. Numerous empirical correlations have been proposed to estimate the pressure drop and liquid holdup for flow of gas-liquid mixtures, only a few of which are in current use. Ansari et al. (1990) published a comprehensive mechanistic model which describes the hydrodynamics of gas-liquid flow in horizontal and vertical pipes. A study was conducted to compare the individual performances of selected correlations and models with data obtained from both the field and laboratory sources. Most of the field data were for annular mist flow. The laboratory data are reported for air-water mixtures and this eliminates the need for flash-type calculations. However, the field data were obtained on hydrocarbon systems, and any inaccuracies in connection with C[sub 7+] fractions may potentially obscure the results of the calculations. It was found that the empirical correlations of Orkiszewski and Duns and Ros appear to be less efficient than methods derived from mechanistic concepts. The Ansari et al. method seems to be the most promising of all, however additional study is required for a definite conclusion. 31 refs., 7 tabs.

  9. The empirical evaluation of thermal conduction coefficient of some liquid composite heat insulating materials

    Science.gov (United States)

    Anisimov, M. V.; Rekunov, V. S.; Babuta, M. N.; Bach Lien, Nguyen Thi Hong

    2016-02-01

    We experimentally determined the coefficients of thermal conductivity of some ultra thin liquid composite heat insulating coatings, for sample #1 λ = 0.086 W/(m·°C), for sample #2 λ = 0.091 W/(m·°C). We performed the measurement error calculation. The actual thermal conduction coefficient of the studied samples was higher than the declared one. The manufactures of liquid coatings might have used some "ideal" conditions when defining heat conductivity in the laboratory or the coefficient was obtained by means of theoretical solution of heat conduction problem in liquid composite insulating media. However, liquid insulating coatings are of great interest to builders, because they allow to warm objects of complex geometric shapes (valve chambers, complex assemblies, etc.), which makes them virtually irreplaceable. The proper accounting of heating qualities of paints will allow to avoid heat loss increase above the specified limits in insulated pipes with heat transfer materials or building structures, as well as protect them from possible thawing in the period of subzero weather.

  10. Evaluation of a Clostridium perfringens Predictive Model, Developed under Isothermal Conditions in Broth, To Predict Growth in Ground Beef during Cooling

    OpenAIRE

    Smith, Sarah; Schaffner, Donald W.

    2004-01-01

    Proper temperature control is essential in minimizing Clostridium perfringens germination, growth, and toxin production. The U.S. Department of Agriculture (USDA) Food Safety and Inspection Service (FSIS) offers two options for the cooling of meat products: follow a standard time-temperature schedule or validate that alternative cooling regimens result in no more than a 1-log10 CFU/g increase of C. perfringens and no growth of Clostridium botulinum. A mathematical model developed by Juneja et...

  11. Synthesis and toxicity evaluation of hydrophobic ionic liquids for volatile organic compounds biodegradation in a two-phase partitioning bioreactor

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Castillo, Alfredo Santiago [Ecole Nationale Supérieure de Chimie de Rennes, CNRS, UMR 6226, 11 Allée de Beaulieu, CS 50837, 35708 Rennes Cedex 7 (France); Université européenne de Bretagne (France); Guihéneuf, Solène, E-mail: solene.guiheneuf@wanadoo.fr [Université européenne de Bretagne, Université de Rennes 1, Sciences Chimiques de Rennes, UMR, CNRS 6226, Groupe Ingénierie Chimique & Molécules Pour le Vivant (ICMV), Bât. 10A, Campus de Beaulieu, Avenue du Général Leclerc, CS 74205, 35042 Rennes cedex (France); Le Guével, Rémy [Plate-forme ImPACcell Structure Fédérative de Recherche BIOSIT Université de Rennes 1, Bat. 8, Campus de Villejean, 2 Avenue du Pr. Leon Bernard, CS 34317, 35043 Rennes Cedex (France); Biard, Pierre-François [Ecole Nationale Supérieure de Chimie de Rennes, CNRS, UMR 6226, 11 Allée de Beaulieu, CS 50837, 35708 Rennes Cedex 7 (France); Université européenne de Bretagne (France); and others

    2016-04-15

    Highlights: • Description of a VOC depollution system suitable with industrial processes, TPPB. • Novel association of TPPB and hydrophobic ionic liquids. • Synthesis of several hydrophobic ionic liquids designed to fit desired properties. • Toxicity evaluation of these ILs towards cells, animals and bacteria. - Abstract: Synthesis of several hydrophobic ionic liquids (ILs), which might be selected as good candidates for degradation of hydrophobic volatile organic compounds in a two-phase partitioning bioreactor (TPPB), were carried out. Several bioassays were also realized, such as toxicity evaluation on activated sludge and zebrafish, cytotoxicity, fluoride release in aqueous phase and biodegradability in order to verify their possible effects in case of discharge in the aquatic environment and/or human contact during industrial manipulation. The synthesized compounds consist of alkylimidazoliums, functionalized imidazoliums, isoqinoliniums, triazoliums, sulfoniums, pyrrolidiniums and morpholiniums and various counter-ions such as: PF{sub 6}{sup −}, NTf{sub 2}{sup −} and NfO{sup −}. Toxicity evaluation on activated sludge of each compound (5% v/v of IL) was assessed by using a glucose uptake inhibition test. Toxicity against zebrafish and cytotoxicity were evaluated by the ImPACCell platform of Rennes (France). Fluoride release in water was estimated by regular measurements using ion chromatography equipment. IL biodegradability was determined by measuring BOD{sub 28} of aqueous samples (compound concentration,1 mM). All ILs tested were not biodegradable; while some of them were toxic toward activated sludge. Isoquinolinium ILs were toxic to human cancerous cell lines. Nevertheless no toxicity was found against zebrafish Danio rerio. Only one IL released fluoride after long-time agitation.

  12. Liquids and liquid mixtures

    CERN Document Server

    Rowlinson, J S; Baldwin, J E; Buckingham, A D; Danishefsky, S

    2013-01-01

    Liquids and Liquid Mixtures, Third Edition explores the equilibrium properties of liquids and liquid mixtures and relates them to the properties of the constituent molecules using the methods of statistical thermodynamics. Topics covered include the critical state, fluid mixtures at high pressures, and the statistical thermodynamics of fluids and mixtures. This book consists of eight chapters and begins with an overview of the liquid state and the thermodynamic properties of liquids and liquid mixtures, including vapor pressure and heat capacities. The discussion then turns to the thermodynami

  13. Temperature responsive cooling apparatus

    Energy Technology Data Exchange (ETDEWEB)

    Weker, M.L.; Stearns, R.M.

    1987-08-11

    A temperature responsive cooling apparatus is described for an air conditioner or refrigeration system in operative association with a reservoir of fluid, the air conditioner or refrigeration system having an air cooled coil and means for producing a current of air for cooling the coil, the temperature responsive cooling apparatus comprising: (a) means for transferring the fluid from the reservoir to the air conditioner temperature responsive cooling apparatus, (b) a fluid control device activated by the current of air for cooling the coil; (c) a temperature activated, nonelectrical device for terminating and initiating the flow of fluid therethrough in an intermittent fashion for enhancing the operability of the compressor associated with the refrigeration system and for reducing the quantity of fluid required to cool the coil of the refrigeration system, (d) a fluid treatment device for preventing, reducing or mitigating the deposition of nonevaporative components on the air cooled coil, and (e) means for dispersing the fluid to the air cooled coil from the fluid control device for cooling the coil and increasing the efficiency of the air conditioner thereby reducing the cost of operating and maintaining the air conditioner without damaging the air conditioner and without the deposition of nonevaporative components thereupon.

  14. Transfer Efficiency and Cooling Cost by Thermal Loss based on Nitrogen Evaporation Method for Superconducting MAGLEV System

    Science.gov (United States)

    Chung, Y. D.; Kim, D. W.; Lee, C. Y.

    2017-07-01

    This paper presents the feasibility of technical fusion between wireless power transfer (WPT) and superconducting technology to improve the transfer efficiency and evaluate operating costs such as refrigerant consumption. Generally, in WPT technology, the various copper wires have been adopted. From this reason, the transfer efficiency is limited since the copper wires of Q value are intrinsically critical point. On the other hand, as superconducting wires keep larger current density and relatively higher Q value, the superconducting resonance coil can be expected as a reasonable option to deliver large transfer power as well as improve the transfer ratio since it exchanges energy at a much higher rate and keeps stronger magnetic fields out. However, since superconducting wires should be cooled indispensably, the cooling cost of consumed refrigerant for resonance HTS wires should be estimated. In this study, the transmission ratios using HTS resonance receiver (Rx) coil and various cooled and noncooled copper resonance Rx coils were presented under non cooled copper antenna within input power of 200 W of 370 kHz respectively. In addition, authors evaluated cooling cost of liquid nitrogen for HTS resonance coil and various cooled copper resonance coils based on nitrogen evaporation method.

  15. Evaluation of Properties of Mineral Trioxide Aggregate with Methyl Cellulose as Liquid.

    Science.gov (United States)

    Dianat, Omid; Naseri, Mandana; Tabatabaei, Seyedeh Farnaz

    2017-01-01

    Mineral trioxide aggregate (MTA) is extensively used in endodontics. However, MTA is difficult to handle because of its granular consistency, low mechanical properties and initial looseness. The objective of this study was to assess the compressive strength (CS), diametral tensile strength (DTS), and pH of set MTA using methyl cellulose as liquid. White ProRoot MTA was used as the control group; modified MTA cement was prepared by mixing Portland cement, bismuth oxide and calcium sulfate (75%, 20% and 5%, respectively) as the experiment group. Methyl cellulose was used as hydrating liquid and compared with distilled water. The data were analyzed by two-way ANOVA. The pH values of modified MTA cement set using deionized water and methyl cellulose were slightly, but not significantly, different (P>0.05). The DTS and CS tests for modified MTA cement hydrated with methyl cellulose showed a significant difference at one day and one week (PMTA.

  16. Evaluation of liquid-fed ceramic melter scale-up correlations

    Energy Technology Data Exchange (ETDEWEB)

    Koegler, S.S.; Mitchell, S.J.

    1988-08-01

    This study was conducted to determine the parameters governing factors of scale for liquid-fed ceramic melters (LFCMs) in order to design full-scale melters using smaller-scale melter data. Results of melter experiments conducted at Pacific Northwest Laboratory (PNL) and Savannah River Laboratory (SRL) are presented for two feed compositions and five different liquid-fed ceramic melters. The melter performance data including nominal feed rate and glass melt rate are correlated as a function of melter surface area. Comparisons are made between the actual melt rate data and melt rates predicted by a cold cap heat transfer model. The heat transfer model could be used in scale-up calculations, but insufficient data are available on the cold cap characteristics. Experiments specifically designed to determine heat transfer parameters are needed to further develop the model. 17 refs.

  17. Engineering evaluation of solids/liquids separation processes applicable to sludge treatment project

    Energy Technology Data Exchange (ETDEWEB)

    Duncan, J.B.

    1998-08-25

    This engineering study looks at the solids/liquids separation unit operations after the acid dissolution of the K Basin sludge treatment. Unit operations considered were centrifugation, filtration (cartridge, cross flow, and high shear filtration) and gravity settling. The recommended unit operations for the solids/liquids separations are based upon the efficiency, complexity, and off-the-shelf availability and adaptability. The unit operations recommended were a Robatel DPC 900 centrifuge followed by a nuclearized 31WM cartridge filter. The Robatel DPC 900 has been successfully employed in the nuclear industry on a world wide scale. The 31WM cartridge filter has been employed for filtration campaigns in both the government and civilian nuclear arenas.

  18. Biomedical Application of Aerospace Personal Cooling Systems

    Science.gov (United States)

    Ku, Yu-Tsuan E.; Lee, Hank C.; Montgomery, Leslie D.; Webbon, Bruce W.; Kliss, Mark (Technical Monitor)

    1997-01-01

    Personal thermoregulatory systems which are used by astronauts to alleviate thermal stress during extravehicular activity have been applied to the therapeutic management of multiple sclerosis. However, little information is available regarding the physiologic and circulatory changes produced by routine operation of these systems. The objectives of this study were to compare the effectiveness of two passive and two active cooling vests and to measure the body temperature and circulatory changes produced by each cooling vest configuration. The MicroClimate Systems and the Life Enhancement Tech(LET) lightweight liquid cooling vests, the Steele Vest and LET's Zipper Front Garment were used to cool the chest region of 10 male and female subjects (25 to 55 yr.) in this study. Calf, forearm and finger blood flows were measured using a tetrapolar impedance rheograph. The subjects, seated in an upright position at normal room temperature (approx.22C), were tested for 60 min. with the cooling system operated at its maximum cooling capacity. Blood flows were recorded continuously using a computer data acquisition system with a sampling frequency of 250 Hz. Oral, right and left ear temperatures and cooling system parameters were logged manually every 5 min. Arm, leg, chest and rectal temperatures; heart rate; respiration; and an activity index were recorded continuously on a U.F.I., Inc. Biolog ambulatory monitor. In general, the male and female subjects' oral and ear temperature responses to cooling were similar for all vest configurations tested. Oral temperatures during the recovery period were significantly (P<0.05) lower than during the control period, approx. 0.2 - 0.5C, for both men and women wearing any of the four different garments. The corresponding ear temperatures were significantly (P<0.05) decreased approx.0.2 - 0.4C by the end of the recovery period. Compared to the control period, no significant differences were found in rectal temperatures during cooling and

  19. The Liquid State

    Indian Academy of Sciences (India)

    gas laws when the gases are compressed and cooled. Otherwise, one cannot account for liquefaction of gases. The picture of intermolecular interaction which emerged from the study of gases is shown in Figure 1. Even in liquids molecules move in random directions with random velocities. This movement of molecules in a ...

  20. Evaluation of Sloped Bottom Tuned Liquid Damper for Reduction of Seismic Response of Tall Buildings

    Science.gov (United States)

    Patil, G. R.; Singh, K. D.

    2016-12-01

    Due to migration of people to urban area, high land costs and use of light weight materials modern buildings tend to be taller, lighter and flexible. These buildings possess low damping. This increases the possibility of failure during earthquake ground motion and also affect the serviceability during wind vibrations. Out of many available techniques today, to reduce the response of structure under dynamic loading, Tuned Liquid Damper (TLD) is a recent technique to mitigate seismic response. However TLD has been used to mitigate the wind induced structural vibrations. Flat bottom TLD gives energy back to the structure after event of dynamic loading and it is termed as beating. Beating affects the performance of TLD. Study attempts to analyze the effectiveness of sloped bottom TLD for reducing seismic vibrations of structure. Concept of equivalent flat bottom LD has been used to analyze sloped bottom TLD. Finite element method (EM) is used to model the structure and the liquid in the TLD. MATLAB code is developed to study the response of structure, the liquid sloshing in the tank and the coupled fluid-structure interaction. A ten storey two bay RC frame is analyzed for few inputs of ground motion. A sinusoidal ground motion corresponding to resonance condition with fundamental frequency of frame is analyzed. In the analysis the inherent damping of structure is not considered. Observations from the study shows that sloped bottom TLD uses less amount of liquid than flat bottom TLD. Also observed that efficiency of sloped bottom TLD can be improved if it is properly tuned.

  1. Evaluation and significance of hyperchromatic crowded groups (HCG in liquid-based paps

    Directory of Open Access Journals (Sweden)

    Chivukula Mamatha

    2007-01-01

    Full Text Available Abstract Objective Hyperchromatic crowded groups (HCG, a term first introduced into the cytology literature by DeMay in 1995, are commonly observed in Pap tests and may rarely be associated with serious but difficult to interpret lesions. In this study, we specifically defined HCG as dark crowded cell groups with more than 15 cells which can be identified at 10× screening magnification. Methods We evaluated consecutive liquid-based (Surepath Pap tests from 601 women (age 17–74 years, mean age 29.4 yrs and observed HCG in 477 cases. In all 477 HCG cases, Pap tests were found to be satisfactory and to contain an endocervical sample. HCG were easily detectible at 10× screening magnification (size up to 400 um, mean 239.5 um and ranged from 1 to 50 (mean 19.5 per Pap slide. Results HCG predominantly represented 3-Dimensional groups of endocervical cells with some nuclear overlap (379/477 – 79%, reactive endocervical cells with relatively prominent nucleoli and some nuclear crowding (29/477 – 6%, clusters of inflammatory cells (25/477 – 5.2%, parabasal cells (22/477 – 4.6%, endometrial cells (1/477 – 0.2%. Epithelial cell abnormalities (ECA were present in only 21 of 477 cases (4.6%. 18 of 21 women with HCG-associated ECA were less than 40 years old; only 3 were =/> 40 years. HCG-associated final abnormal Pap test interpretations were as follows: ASCUS (6/21 – 28%, LSIL (12/21 – 57%, ASC-H (2/21 – 9.5%, and HSIL/CIN2-3 (3/21 – 14%. The association of HCG with ECA was statistically significant (p = 0.0174. chi-square test. In patients with ECA, biopsy results were available in 10 cases, and 4 cases of biopsy-proven CIN2/3 were detected. Among these four cases, HCG in the Pap tests, in retrospect represented the lesional high grade cells in three cases (one HSIL case and two ASC-H cases. Interestingly, none of the 124 cases without HCG were found to have an epithelial cell abnormality. Conclusion We conclude: a. HCG are observed

  2. Evaluation of industrially applied heat-transfer fluids as liquid organic hydrogen carrier systems.

    Science.gov (United States)

    Brückner, Nicole; Obesser, Katharina; Bösmann, Andreas; Teichmann, Daniel; Arlt, Wolfgang; Dungs, Jennifer; Wasserscheid, Peter

    2014-01-01

    Liquid organic hydrogen carrier (LOHC) systems offer a very attractive method for the decentralized storage of renewable excess energy. In this contribution, industrially well-established heat-transfer oils (typically sold under trade names, e.g., Marlotherm) are proposed as a new class of LOHC systems. It is demonstrated that the liquid mixture of isomeric dibenzyltoluenes (m.p. -39 to -34 °C, b.p. 390 °C) can be readily hydrogenated to the corresponding mixture of perhydrogenated analogues by binding 6.2 wt% of H2. The liquid H2 -rich form can be stored and transported similarly to diesel fuel. It readily undergoes catalytic dehydrogenation at temperatures above 260 °C, which proves its applicability as a reversible H2 carrier. The presented LOHC systems are further characterized by their excellent technical availability at comparably low prices, full registration of the H2 -lean forms, and excellent thermal stabilities. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Performance evaluation of microbial electrochemical systems operated with Nafion and supported ionic liquid membranes.

    Science.gov (United States)

    Koók, László; Nemestóthy, Nándor; Bakonyi, Péter; Zhen, Guangyin; Kumar, Gopalakrishnan; Lu, Xueqin; Su, Lianghu; Saratale, Ganesh Dattatraya; Kim, Sang-Hyoun; Gubicza, László

    2017-05-01

    In this work, the performance of dual-chamber microbial fuel cells (MFCs) constructed either with commonly used Nafion® proton exchange membrane or supported ionic liquid membranes (SILMs) was assessed. The behavior of MFCs was followed and analyzed by taking the polarization curves and besides, their efficiency was characterized by measuring the electricity generation using various substrates such as acetate and glucose. By using the SILMs containing either [C6mim][PF6] or [Bmim][NTf2] ionic liquids, the energy production of these MFCs from glucose was comparable to that obtained with the MFC employing polymeric Nafion® and the same substrate. Furthermore, the MFC operated with [Bmim][NTf2]-based SILM demonstrated higher energy yield in case of low acetate loading (80.1 J g-1 CODin m-2 h-1) than the one with the polymeric Nafion® N115 (59 J g-1 CODin m-2 h-1). Significant difference was observed between the two SILM-MFCs, however, the characteristics of the system was similar based on the cell polarization measurements. The results suggest that membrane-engineering applying ionic liquids can be an interesting subject field for bioelectrochemical system research. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Evaluation of Properties of Mineral Trioxide Aggregate with Methyl Cellulose as Liquid

    Directory of Open Access Journals (Sweden)

    Omid Dianat

    2017-02-01

    Full Text Available Objectives: Mineral trioxide aggregate (MTA is extensively used in endodontics. However, MTA is difficult to handle because of its granular consistency, low mechanical properties and initial looseness. The objective of this study was to assess the compressive strength (CS, diametral tensile strength (DTS, and pH of set MTA using methyl cellulose as liquid.Materials and Methods: White ProRoot MTA was used as the control group; modified MTA cement was prepared by mixing Portland cement, bismuth oxide and calcium sulfate (75%, 20% and 5%, respectively as the experiment group. Methyl cellulose was used as hydrating liquid and compared with deionized water. The data were analyzed by two-way ANOVA.Results: The pH values of modified MTA cement set using deionized water and methyl cellulose were slightly, but not significantly, different (P>0.05. The DTS and CS tests for modified MTA cement hydrated with methyl cellulose showed a significant difference at one day and one week (P<0.05.Conclusions: The results suggest that using methyl cellulose as the hydrating liquid enhances some mechanical properties but does not compromise pH of white ProRoot MTA.Keywords: Compressive Strength; Mineral Trioxide Aggregate; Tensile Strength

  5. Characteristic Evaluation on the Cooling Performance of an Electrical Air Conditioning System Using R744 for a Fuel Cell Electric Vehicle

    Directory of Open Access Journals (Sweden)

    Moo-Yeon Lee

    2012-05-01

    Full Text Available The objective of this study was to investigate the cooling performance characteristics of an electrical air conditioning system using R744 as an alternative of R-134a for a fuel cell electric vehicle. In order to analyze the cooling performance characteristics of the air conditioning system using R744 for a fuel cell electric vehicle, an electrical air conditioning system using R744 was developed and tested under various operating conditions according to both inlet air conditions of the gas cooler and evaporator and compressor speed. The cooling capacity and coefficient of performance (COP forcooling of the tested air conditioning system were up to 6.4 kW and 2.5, respectively. In addition, the electrical air conditioning system with R744 using an inverter driven compressor showed better performance than the conventional air conditioning system with R-134a under the same operating conditions. The observed cooling performance of the developed electrical air conditioning system was found to be sufficient for cooling loads under various real driving conditions for a fuel cell electric vehicle.

  6. Evaporative Cooling Availability in Water Based Sensible Cooling Systems

    OpenAIRE

    Costelloe, Ben; Finn, Donal

    2001-01-01

    Recent developments have prompted a review of evaporative cooling technology as an effective means of cooling modern deep plan buildings. Prominent among these developments is the success of high temperature sensible cooling systems, such as chilled ceilings, which require a supply of cooling water at 14 to 18°C. Crucial to the success of evaporative cooling technology, as a significant means of cooling in modern applications, is the ability to generate cooling water, in an indirect circuit, ...

  7. Radiant Floor Cooling Systems

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.

    2008-01-01

    In many countries, hydronic radiant floor systems are widely used for heating all types of buildings such as residential, churches, gymnasiums, hospitals, hangars, storage buildings, industrial buildings, and smaller offices. However, few systems are used for cooling.This article describes a floor...... cooling system that includes such considerations as thermal comfort of the occupants, which design parameters will influence the cooling capacity and how the system should be controlled. Examples of applications are presented....

  8. Translucency and color stability of resin composite and dental adhesives as modeling liquids - A one-year evaluation.

    Science.gov (United States)

    Sedrez-Porto, José Augusto; Münchow, Eliseu Aldrighi; Cenci, Maximiliano Sérgio; Pereira-Cenci, Tatiana

    2017-07-03

    The aim of this study is to evaluate the influence of modeling liquids on the translucency and color shade of resin composites (RCs) after one year of storage. RC specimens were prepared using either a conventional insertion technique (control; without modeling liquid) or a restorative dental modeling insertion technique (RDMIT) with dental adhesives as modeling liquids (Scotchbond™ Multi-Purpose [SBMP; 3M ESPE] or Adper™ Single Bond 2 [SB; 3M ESPE]). The initial colors of the specimens were obtained with a digital spectrophotometer and the CIEL*a*b* color system, after which specimens were stored (37°C) in distilled water or red wine for 12 months. Color measurements were reassessed after 6 and 12 months of storage, and scanning electron microscopy was performed after 12 months. Translucency and color change (ΔE*) were calculated and analyzed using ANOVA and Tukey's test (α = 5%). RC samples prepared via RDMIT showed a translucency similar to that of control samples. ΔE* was also less intense for RCs containing SBMP than for RCs containing SB. Specimens stored in wine showed a clear pattern of degradation, especially in the control group, and surface degradation seemed to be less intense for specimens prepared with SBMP and SB than for specimens without. Specimens stored in water did not show clear evidence of surface degradation. RDMIT appears to be an interesting approach to reduce ΔE* in RCs over time without negative effects on the translucency of the material. However, the modeling liquid should feature a hydrophobic composition, similar to that used in the SBMP group, the achieve the best results.

  9. Translucency and color stability of resin composite and dental adhesives as modeling liquids – A one-year evaluation

    Directory of Open Access Journals (Sweden)

    José Augusto SEDREZ-PORTO

    2017-07-01

    Full Text Available Abstract The aim of this study is to evaluate the influence of modeling liquids on the translucency and color shade of resin composites (RCs after one year of storage. RC specimens were prepared using either a conventional insertion technique (control; without modeling liquid or a restorative dental modeling insertion technique (RDMIT with dental adhesives as modeling liquids (Scotchbond™ Multi-Purpose [SBMP; 3M ESPE] or Adper™ Single Bond 2 [SB; 3M ESPE]. The initial colors of the specimens were obtained with a digital spectrophotometer and the CIEL*a*b* color system, after which specimens were stored (37°C in distilled water or red wine for 12 months. Color measurements were reassessed after 6 and 12 months of storage, and scanning electron microscopy was performed after 12 months. Translucency and color change (ΔE* were calculated and analyzed using ANOVA and Tukey’s test (α = 5%. RC samples prepared via RDMIT showed a translucency similar to that of control samples. ΔE* was also less intense for RCs containing SBMP than for RCs containing SB. Specimens stored in wine showed a clear pattern of degradation, especially in the control group, and surface degradation seemed to be less intense for specimens prepared with SBMP and SB than for specimens without. Specimens stored in water did not show clear evidence of surface degradation. RDMIT appears to be an interesting approach to reduce ΔE* in RCs over time without negative effects on the translucency of the material. However, the modeling liquid should feature a hydrophobic composition, similar to that used in the SBMP group, the achieve the best results.

  10. Evaluation of the ionization quenching correction for several liquid scintillators; Evaluacion de la extincion por ionizacion para diversos liquidos centelleadores

    Energy Technology Data Exchange (ETDEWEB)

    Los Arcos, J. M.; Borras, C.

    1990-07-01

    The most appropriate computational model for the ionization quenching function Q(E) is analyzed for electrons in liquid scintillators. A numerical evaluation of Q(E) from 0.1 keV to 3 MeV which the kB parameter varying between 0.005 and 0.010 cm/MeV is presented for seven scintillators; Toluene, Toluene-Alcohol, PCS, Toluene-CCl4, INSTAGEL, Dioxane-Naphtalene and HISAFE II. The numerical result are summarized as tables of Ieast squares fitting coefficient which make easy the computation of Q(E). (Author)

  11. Design and Performance Evaluation of Optical Ethernet Switching Architecture with Liquid Crystal on Silicon-Based Beam-Steering Technology

    Science.gov (United States)

    Cheng, Yuh-Jiuh; Chou, H.-H.; Shiau, Yhi; Cheng, Shu-Ying

    2016-07-01

    A non-blocking optical Ethernet switching architecture with liquid crystal on a silicon-based beam-steering switch and optical output buffer strategies are proposed. For preserving service packet sequencing and fairness of routing sequence, priority and round-robin algorithms are adopted at the optical output buffer in this research. Four methods were used to implement tunable fiber delay modules for the optical output buffers to handle Ethernet packets with variable bit-rates. The results reported are based on the simulations performed to evaluate the proposed switching architecture with traffic analysis under a traffic model captured from a real-core network.

  12. Sterilization by Cooling in Isochoric Conditions: The Case of Escherichia coli.

    Science.gov (United States)

    Salinas-Almaguer, Samuel; Angulo-Sherman, Abril; Sierra-Valdez, Francisco Javier; Mercado-Uribe, Hilda

    2015-01-01

    High hydrostatic pressure (HHP) affects the structure, metabolism and survival of micro-organisms including bacteria. For this reason HHP is a promising treatment in the food industry. The aim of this work is to evaluate the effect of high pressure, under isochoric cooling conditions, on Escherichia coli, where such high pressure develops due to the fact water cannot expand. We combine survival curves obtained by spectrophotometry and images of atomic force microscopy in this study. Our results show that cooling at -20 and -30°C leads to a partial destruction of a Escherichia coli population. However, cooling at -15°C causes a total extermination of bacteria. This intriguing result is explained by the phase diagram of water. In the first case, the simultaneous formation of ice III and ice Ih crystals provides a safe environment for bacteria. In the second case (-15°C) Escherichia coli remains in a metastable and amorphous free-of-crystals liquid subjected to high pressure. Our work is the first experimental study carried out to inactivate Escherichia coli under isochoric cooling conditions. Unlike HHP, which is based on the application of an external load to augment the pressure, this technique only requires cooling. The method could be used for annihilation of other Escherichia coli strains and perhaps other micro-organisms.

  13. Sterilization by Cooling in Isochoric Conditions: The Case of Escherichia coli.

    Directory of Open Access Journals (Sweden)

    Samuel Salinas-Almaguer

    Full Text Available High hydrostatic pressure (HHP affects the structure, metabolism and survival of micro-organisms including bacteria. For this reason HHP is a promising treatment in the food industry. The aim of this work is to evaluate the effect of high pressure, under isochoric cooling conditions, on Escherichia coli, where such high pressure develops due to the fact water cannot expand. We combine survival curves obtained by spectrophotometry and images of atomic force microscopy in this study. Our results show that cooling at -20 and -30°C leads to a partial destruction of a Escherichia coli population. However, cooling at -15°C causes a total extermination of bacteria. This intriguing result is explained by the phase diagram of water. In the first case, the simultaneous formation of ice III and ice Ih crystals provides a safe environment for bacteria. In the second case (-15°C Escherichia coli remains in a metastable and amorphous free-of-crystals liquid subjected to high pressure. Our work is the first experimental study carried out to inactivate Escherichia coli under isochoric cooling conditions. Unlike HHP, which is based on the application of an external load to augment the pressure, this technique only requires cooling. The method could be used for annihilation of other Escherichia coli strains and perhaps other micro-organisms.

  14. Initial Cooling Experiment (ICE)

    CERN Multimedia

    Photographic Service; CERN PhotoLab

    1978-01-01

    In 1977, in a record-time of 9 months, the magnets of the g-2 experiment were modified and used to build a proton/antiproton storage ring: the "Initial Cooling Experiment" (ICE). It served for the verification of the cooling methods to be used for the "Antiproton Project". Stochastic cooling was proven the same year, electron cooling followed later. Also, with ICE the experimental lower limit for the antiproton lifetime was raised by 9 orders of magnitude: from 2 microseconds to 32 hours. For its previous life as g-2 storage ring, see 7405430. More on ICE: 7711282, 7809081, 7908242.

  15. Turbine airfoil cooling system with cooling systems using high and low pressure cooling fluids

    Science.gov (United States)

    Marsh, Jan H.; Messmann, Stephen John; Scribner, Carmen Andrew

    2017-10-25

    A turbine airfoil cooling system including a low pressure cooling system and a high pressure cooling system for a turbine airfoil of a gas turbine engine is disclosed. In at least one embodiment, the low pressure cooling system may be an ambient air cooling system, and the high pressure cooling system may be a compressor bleed air cooling system. In at least one embodiment, the compressor bleed air cooling system in communication with a high pressure subsystem that may be a snubber cooling system positioned within a snubber. A delivery system including a movable air supply tube may be used to separate the low and high pressure cooling subsystems. The delivery system may enable high pressure cooling air to be passed to the snubber cooling system separate from low pressure cooling fluid supplied by the low pressure cooling system to other portions of the turbine airfoil cooling system.

  16. Wet cooling towers: rule-of-thumb design and simulation

    Energy Technology Data Exchange (ETDEWEB)

    Leeper, Stephen A. [EG and G Idaho, Inc., Idaho Falls, ID (United States)

    1981-07-01

    A survey of wet cooling tower literature was performed to develop a simplified method of cooling tower design and simulation for use in power plant cycle optimization. The theory of heat exchange in wet cooling towers is briefly summarized. The Merkel equation (the fundamental equation of heat transfer in wet cooling towers) is presented and discussed. The cooling tower fill constant (Ka) is defined and values derived. A rule-of-thumb method for the optimized design of cooling towers is presented. The rule-of-thumb design method provides information useful in power plant cycle optimization, including tower dimensions, water consumption rate, exit air temperature, power requirements and construction cost. In addition, a method for simulation of cooling tower performance at various operating conditions is presented. This information is also useful in power plant cycle evaluation. Using the information presented, it will be possible to incorporate wet cooling tower design and simulation into a procedure to evaluate and optimize power plant cycles.

  17. Standing Slow MHD Waves in Radiatively Cooling Coronal Loops

    Indian Academy of Sciences (India)

    In particular, the background plasma is assumed to be radiatively cooling. The effects of cooling on longitudinal slow MHD modes is analytically evaluated by choosing a simple form of radiative function, that ensures the temperature evolution of the background plasma due to radiation, coincides with the observed cooling ...

  18. Immersion Cooling of Electronics in DoD Installations

    Energy Technology Data Exchange (ETDEWEB)

    Coles, Henry [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Herrlin, Magnus [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2017-08-15

    A considerable amount of energy is consumed to cool electronic equipment in data centers. A method for substantially reducing the energy needed for this cooling was demonstrated. The method involves immersing electronic equipment in a non-conductive liquid that changes phase from a liquid to a gas. The liquid used was 3M Novec 649. Two-phase immersion cooling using this liquid is not viable at this time. The primary obstacles are IT equipment failures and costs. However, the demonstrated technology met the performance objectives for energy efficiency and greenhouse gas reduction. Before commercialization of this technology can occur, a root cause analysis of the failures should be completed, and the design changes proven.

  19. Performance evaluation of a solar air-heating and nocturnal cooling system in CSU Solar House II. Final report, June 1, 1977-September 30, 1978

    Energy Technology Data Exchange (ETDEWEB)

    Karaki, S.

    1979-04-01

    The solar heating system in Solar House II consists of 67.1 m/sup 2/ of double-glazed air-heating collectors with flat-black absorbers, 10.3 m/sup 3/ of pebble bed storage, air-to-water heat exchanger for preheating domestic water and one blower to circulate the air through the system. The nocturnal cooling system consists of an evaporative cooler and utilizes the pebble bed for cool storage. A schematic diagram of the system is shown.

  20. Majorana One-Tonne Cryostat Cooling Conceptual Feasibility Study Rev 1

    Energy Technology Data Exchange (ETDEWEB)

    Reid, Douglas J.; Fast, James E.; Orrell, John L.; Aguayo Navarrete, Estanislao

    2011-06-27

    This report evaluates the conceptual plans for a cryostat cooling design for the MAJORANA DEMONSTRATOR (MJD) one-tonne (S4) experiment. This document is based upon previous design work and experimental results used to evaluate the current MJD thermal design. A feasibility study of a cooling system for S4 based on the MJD thermosiphon experiment is presented. The one-tonne experiment will be a scaled up version of the MJD. There will be many cryostats in the S4 experiment. In this document a cryostat with up to 19 strings of germanium crystals is analyzed. Aside from an extra outer ring of crystals, the geometry of the cryostat for S4 is very similar to that for the MJD thermosiphon experiment. The materials used in the fabrication of both of these ultra-low background experiments will be underground-electroformed copper. The current MJD uses a two-phase liquid-gas cooling system to provide constant operating temperature. This document presents a theoretical investigation of a cooling system for the S4 experiment and evaluates the heat transfer performance requirements for such a system.

  1. An intercomparison of radar-based liquid cloud microphysics retrievals and implications for model evaluation studies

    Directory of Open Access Journals (Sweden)

    D. Huang

    2012-06-01

    Full Text Available This paper presents a statistical comparison of three cloud retrieval products of the Atmospheric Radiation Measurement (ARM program at the Southern Great Plains (SGP site from 1998 to 2006: MICROBASE, University of Utah (UU, and University of North Dakota (UND products. The probability density functions of the various cloud liquid water content (LWC retrievals appear to be consistent with each other. While the mean MICROBASE and UU cloud LWC retrievals agree well in the middle of cloud, the discrepancy increases to about 0.03 gm−3 at cloud top and cloud base. Alarmingly large differences are found in the droplet effective radius (re retrievals. The mean MICROBASE re is more than 6 μm lower than the UU re, whereas the discrepancy is reduced to within 1 μm if columns containing raining and/or mixed-phase layers are excluded from the comparison. A suite of stratified comparisons and retrieval experiments reveal that the LWC difference stems primarily from rain contamination, partitioning of total liquid later path (LWP into warm and supercooled liquid, and the input cloud mask and LWP. The large discrepancy among the re retrievals is mainly due to rain contamination and the presence of mixed-phase layers. Since rain or ice particles are likely to dominate radar backscattering over cloud droplets, the large discrepancy found in this paper can be thought of as a physical limitation of single-frequency radar approaches. It is therefore suggested that data users should use the retrievals with caution when rain and/or mixed-phase layers are present in the column.

  2. Optimum cooling of data centers application of risk assessment and mitigation techniques

    CERN Document Server

    Dai, Jun; Das, Diganta; Pecht, Michael G

    2014-01-01

    This book provides data center designers and operators with methods by which to assess and mitigate the risks associated with utilization of optimum cooling solutions. The goal is to provide readers with sufficient knowledge to implement measures such as free air cooling or direct liquid immersion cooling properly, or combination of existing and emerging cooling technologies in data centers, base stations, and server farms. This book also: Discusses various telecommunication infrastructures, with an emphasis on data centers and base stations Covers the most commonly known energy and power management techniques, as well as emerging cooling solutions for data centers Describes the risks to the electronic equipment fitted in these installations and the methods of risk mitigation Devotes  a particular focus to an up-to-date review of the emerging cooling methods (such as free air cooling and direct liquid immersion cooling) and tools and best practices for designers, technology developers, installation operators...

  3. Evaluation of Carbon Composite Overwrap Pressure Vessels Fabricated Using Ionic Liquid Epoxies Project

    Science.gov (United States)

    Grugel, Richard

    2015-01-01

    The intent of the work proposed here is to ascertain the viability of ionic liquid (IL) epoxy based carbon fiber composites for use as storage tanks at cryogenic temperatures. This IL epoxy has been specifically developed to address composite cryogenic tank challenges associated with achieving NASA's in-space propulsion and exploration goals. Our initial work showed that an unadulterated ionic liquid (IL) carbon-fiber composite exhibited improved properties over an optimized commercial product at cryogenic temperatures. Subsequent investigative work has significantly improved the IL epoxy and our first carbon-fiber Composite Overwrap Pressure Vessel (COPV) was successfully fabricated. Here additional COPVs, using a further improved IL epoxy, will be fabricated and pressure tested at cryogenic temperatures with the results rigorously analyzed. Investigation of the IL composite for lower pressure liner-less cryogenic tank applications will also be initiated. It is expected that the current Technology Readiness Level (TRL) will be raised from about TRL 3 to TRL 5 where unambiguous predictions for subsequent development/testing can be made.

  4. Laser diode package with enhanced cooling

    Energy Technology Data Exchange (ETDEWEB)

    Deri, Robert J [Pleasanton, CA; Kotovsky, Jack [Oakland, CA; Spadaccini, Christopher M [Oakland, CA

    2011-09-13

    A laser diode package assembly includes a reservoir filled with a fusible metal in close proximity to a laser diode. The fusible metal absorbs heat from the laser diode and undergoes a phase change from solid to liquid during the operation of the laser. The metal absorbs heat during the phase transition. Once the laser diode is turned off, the liquid metal cools off and resolidifies. The reservoir is designed such that that the liquid metal does not leave the reservoir even when in liquid state. The laser diode assembly further includes a lid with one or more fin structures that extend into the reservoir and are in contact with the metal in the reservoir.

  5. Laser diode package with enhanced cooling

    Energy Technology Data Exchange (ETDEWEB)

    Deri, Robert J; Kotovsky, Jack; Spadaccini, Christopher M

    2012-06-26

    A laser diode package assembly includes a reservoir filled with a fusible metal in close proximity to a laser diode. The fusible metal absorbs heat from the laser diode and undergoes a phase change from solid to liquid during the operation of the laser. The metal absorbs heat during the phase transition. Once the laser diode is turned off, the liquid metal cools off and resolidifies. The reservoir is designed such that that the liquid metal does not leave the reservoir even when in liquid state. The laser diode assembly further includes a lid with one or more fin structures that extend into the reservoir and are in contact with the metal in the reservoir.

  6. Laser diode package with enhanced cooling

    Energy Technology Data Exchange (ETDEWEB)

    Deri, Robert J [Pleasanton, CA; Kotovsky, Jack [Oakland, CA; Spadaccini, Christopher M [Oakland, CA

    2012-06-12

    A laser diode package assembly includes a reservoir filled with a fusible metal in close proximity to a laser diode. The fusible metal absorbs heat from the laser diode and undergoes a phase change from solid to liquid during the operation of the laser. The metal absorbs heat during the phase transition. Once the laser diode is turned off, the liquid metal cools off and resolidifies. The reservoir is designed such that that the liquid metal does not leave the reservoir even when in liquid state. The laser diode assembly further includes a lid with one or more fin structures that extend into the reservoir and are in contact with the metal in the reservoir.

  7. Central cooling: absorptive chillers

    Energy Technology Data Exchange (ETDEWEB)

    Christian, J.E.

    1977-08-01

    This technology evaluation covers commercially available single-effect, lithium-bromide absorption chillers ranging in nominal cooling capacities of 3 to 1,660 tons and double-effect lithium-bromide chillers from 385 to 1,060 tons. The nominal COP measured at operating conditions of 12 psig input steam for the single-effect machine, 85/sup 0/ entering condenser water, and 44/sup 0/F exiting chilled-water, ranges from 0.6 to 0.65. The nominal COP for the double-effect machine varies from 1.0 to 1.15 with 144 psig entering steam. Data are provided to estimate absorption-chiller performance at off-nominal operating conditions. The part-load performance curves along with cost estimating functions help the system design engineer select absorption equipment for a particular application based on life-cycle costs. Several suggestions are offered which may be useful for interfacing an absorption chiller with the remaining Integrated Community Energy System. The ammonia-water absorption chillers are not considered to be readily available technology for ICES application; therefore, performance and cost data on them are not included in this evaluation.

  8. Evaluation of a pediatric liquid formulation to improve 6-mercaptopurine therapy in children

    DEFF Research Database (Denmark)

    Tiphaine, Adam de Beaumais; Hjalgrim, Lisa Lynqsie; Nersting, Jacob

    2016-01-01

    and evaluated in the target population. Preclinical and clinical evaluations were performed according to a Pediatric Investigation Plan, in order to apply for a Pediatric Use Marketing Authorization. METHODS: The pre-clinical study assessed the maximum tolerated dosage-volume and evaluated local mucosal...

  9. Solar absorption cooling

    NARCIS (Netherlands)

    Kim, D.S.

    2007-01-01

    As the world concerns more and more on global climate changes and depleting energy resources, solar cooling technology receives increasing interests from the public as an environment-friendly and sustainable alternative. However, making a competitive solar cooling machine for the market still

  10. Cooling of electronic equipment

    DEFF Research Database (Denmark)

    A. Kristensen, Anders Schmidt

    2003-01-01

    Cooling of electronic equipment is studied. The design size of electronic equipment decrease causing the thermal density to increase. This affect the cooling which can cause for example failures of critical components due to overheating or thermal induced stresses. Initially a pin fin heat sink...

  11. Measure Guideline: Ventilation Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Springer, D.; Dakin, B.; German, A.

    2012-04-01

    The purpose of this measure guideline on ventilation cooling is to provide information on a cost-effective solution for reducing cooling system energy and demand in homes located in hot-dry and cold-dry climates. This guideline provides a prescriptive approach that outlines qualification criteria, selection considerations, and design and installation procedures.

  12. The final cool down

    CERN Multimedia

    Thursday 29th May, the cool-down of the final sector (sector 4-5) of LHC has begun, one week after the start of the cool-down of sector 1-2. It will take five weeks for the sectors to be cooled from room temperature to 5 K and a further two weeks to complete the cool down to 1.9 K and the commissioning of cryogenic instrumentation, as well as to fine tune the cryogenic plants and the cooling loops of cryostats.Nearly a year and half has passed since sector 7-8 was cooled for the first time in January 2007. For Laurent Tavian, AT/CRG Group Leader, reaching the final phase of the cool down is an important milestone, confirming the basic design of the cryogenic system and the ability to operate complete sectors. “All the sectors have to operate at the same time otherwise we cannot inject the beam into the machine. The stability and reliability of the cryogenic system and its utilities are now very important. That will be the new challenge for the coming months,” he explains. The status of the cool down of ...

  13. Renewables for Heating and Cooling

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2007-07-01

    This timely report examines the technologies, current markets and relative costs for heat and cold production using biomass, geothermal and solar-assisted systems. It evaluates a range of national case studies and relevant policies. Should the successful and more cost-effective policies be implemented by other countries, then the relatively untapped economic potential of renewable energy heating and cooling systems could be better realised, resulting in potential doubling of the present market within the next few years.

  14. Emerging Two-Phase Cooling Technologies for Power Electronic Inverters

    Energy Technology Data Exchange (ETDEWEB)

    Hsu, J.S.

    2005-08-17

    In order to meet the Department of Energy's (DOE's) FreedomCAR and Vehicle Technologies (FVCT) goals for volume, weight, efficiency, reliability, and cost, the cooling of the power electronic devices, traction motors, and generators is critical. Currently the power electronic devices, traction motors, and generators in a hybrid electric vehicle (HEV) are primarily cooled by water-ethylene glycol (WEG) mixture. The cooling fluid operates as a single-phase coolant as the liquid phase of the WEG does not change to its vapor phase during the cooling process. In these single-phase systems, two cooling loops of WEG produce a low temperature (around 70 C) cooling loop for the power electronics and motor/generator, and higher temperature loop (around 105 C) for the internal combustion engine. There is another coolant option currently available in automobiles. It is possible to use the transmission oil as a coolant. The oil temperature exists at approximately 85 C which can be utilized to cool the power electronic and electrical devices. Because heat flux is proportional to the temperature difference between the device's hot surface and the coolant, a device that can tolerate higher temperatures enables the device to be smaller while dissipating the same amount of heat. Presently, new silicon carbide (SiC) devices and high temperature direct current (dc)-link capacitors, such as Teflon capacitors, are available but at significantly higher costs. Higher junction temperature (175 C) silicon (Si) dies are gradually emerging in the market, which will eventually help to lower hardware costs for cooling. The development of high-temperature devices is not the only way to reduce device size. Two-phase cooling that utilizes the vaporization of the liquid to dissipate heat is expected to be a very effective cooling method. Among two-phase cooling methods, different technologies such as spray, jet impingement, pool boiling and submersion, etc. are being developed. The

  15. Experimental and numerical investigation on the performance of an internally cooled dehumidifier

    Science.gov (United States)

    Turgut, Oguz Emrah; Çoban, Mustafa Turhan

    2016-12-01

    Liquid desiccant based dehumidifiers are important components of the air conditioning applications. Internally cooled dehumidifiers with liquid desiccants are deemed to be superior to the adiabatic types, thanks to the cooling medium which takes away the latent heat of vaporization occured when moist air contacts with liquid desiccant. However, its utilization in industrial applications is restricted due to the inherent corrosive characteristics of the liquid desiccants. In this study, an experimental chamber is built for epoxy coated plate fin type dehumidifier which is used in order to diminish the corrosive effect of the lithium chloride aqueous solution. Dehumidification effectiveness and moisture removal rate, two parameter indices, are adopted to measure the performance of the air conditioning system. The effect of inlet operating parameters on moisture removal rates is extensively analyzed. Two dimensional numerical model adapted from the conservation principles is utilized for obtainment of output parameters. Experimental results are compared with the numerical model and comparisons show that numerical outputs agrees with the experimental results. And also, dehumidification performance of lithium chloride and lithium bromide aqueous solutions are evaluated and compared against each other.

  16. Emergency Cooling of Nuclear Power Plant Reactors With Heat Removal By a Forced-Draft Cooling Tower

    Energy Technology Data Exchange (ETDEWEB)

    Murav’ev, V. P., E-mail: murval1@mail.ru

    2016-07-15

    The feasibility of heat removal during emergency cooling of a reactor by a forced-draft cooling tower with accumulation of the peak heat release in a volume of precooled water is evaluated. The advantages of a cooling tower over a spray cooling pond are demonstrated: it requires less space, consumes less material, employs shorter lines in the heat removal system, and provides considerably better protection of the environment from wetting by entrained moisture.

  17. INITIAL COOLING EXPERIMENT (ICE)

    CERN Multimedia

    CERN PhotoLab

    1979-01-01

    ICE was built in 1977, using the modified bending magnets of the g-2 muon storage ring (see 7405430). Its purpose was to verify the validity of stochastic and electron cooling for the antiproton project. Stochastic cooling proved a resounding success early in 1978 and the antiproton project could go ahead, now entirely based on stochastic cooling. Electron cooling was experimented with in 1979. The 26 kV equipment is housed in the cage to the left of the picture, adjacent to the "e-cooler" located in a straight section of the ring. With some modifications, the cooler was later transplanted into LEAR (Low Energy Antiproton Ring) and then, with further modifications, into the AD (Antiproton Decelerator), where it cools antiprotons to this day (2006). See also: 7711282, 7802099, 7809081.

  18. Initial Cooling Experiment (ICE)

    CERN Multimedia

    CERN PhotoLab

    1978-01-01

    ICE was built in 1977, in a record time of 9 months, using the modified bending magnets of the g-2 muon storage ring. Its purpose was to verify the validity of stochastic and electron cooling for the antiproton project, to be launched in 1978. Already early in 1978, stochastic cooling proved a resounding success, such that the antiproton (p-pbar)project was entirely based on it. Tests of electron cooling followed later: protons of 46 MeV kinetic energy were cooled with an electron beam of 26 kV and 1.3 A. The cage seen prominently in the foreground houses the HV equipment, adjacent to the "cooler" installed in a straight section of the ring. With some modifications, the cooler was later transplanted into LEAR (Low Energy Antiproton Ring) and then, with further modifications, into the AD (Antiproton Decelerator), where it cools antiprotons to this day (2006). See also: 7711282, 7802099, 7908242.

  19. Development and evaluation of consolidated bioprocessing yeast for ethanol production from ionic liquid-pretreated bagasse.

    Science.gov (United States)

    Amoah, Jerome; Ishizue, Naoya; Ishizaki, Miki; Yasuda, Misa; Takahashi, Kenji; Ninomiya, Kazuaki; Yamada, Ryosuke; Kondo, Akihiko; Ogino, Chiaki

    2017-12-01

    This work aimed to study the use of consolidated bioprocess (CBP) yeast expressing five cellulase genes (BGL, XYNII, EGII, CBHI and CBHII) for ethanol production from ionic liquid-pretreated bagasse and Laubholz unbleached Kraft pulp (LUKP). A proposed screening method shows that the optimal cellulase ratio varies for each biomass substrate, and thus it is essential to breed CBP yeast having optimal cellulase-displaying ratio for the target biomass. CBP yeast specialized towards bagasse produced 0.93g/l ethanol whiles that for LUKP produced 0.71g/l ethanol, which is approximately 4 and 2-fold, respectively, higher than that of the wild type. The cell-surface displayed enzymes synergistically contributed to the degradation of the biomass. The developed CBP yeast is a potential cheap source for consolidated bioprocessing of ethanol and the proposed screening method can be used for matching CBP yeast to a target biomass. Copyright © 2017. Published by Elsevier Ltd.

  20. Evaluation of microstructure and mechanical properties of liquid phase diffusion bonded ODS steels

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Sanghoon, E-mail: sh-noh@iae.kyoto-u.ac.jp [Graduate School of Energy Science, Kyoto University, Gokasho, Uji, Kyoto (Japan); Kasada, Ryuta; Oono, Naoko; Iwata, Noriyuki; Kimura, Akihiko [Institute of Advanced Energy, Kyoto University, Gokasho, Uji, Kyoto (Japan)

    2010-12-15

    Transient liquid phase bonding (TLPB) was employed to join ODS ferritic steel blocks using an amorphous inset material based on Fe-3B-5Si composition with high vacuum uni-axial hot press. The microstructure and mechanical properties were investigated. The TLPB ODS steel showed rather homogeneous distribution of the insert material elements at joined region, while Y-Ti-O precipitation and grain growth up to 20 {mu}m occurred at the region. The TLPB ODS steel had a fairly good tensile strength, which was up to 90% of base material, at temperatures from room temperature to 700 deg. C. However, it showed poor elongation and impact fracture energy compared to base material, which is considered to be due to the existence of Y-Ti-O precipitate at bonding interface and large grained insert material.