WorldWideScience

Sample records for european water samples

  1. EU-wide survey of polar organic persistent pollutants in European river waters

    International Nuclear Information System (INIS)

    Loos, Robert; Gawlik, Bernd Manfred; Locoro, Giovanni; Rimaviciute, Erika; Contini, Serafino; Bidoglio, Giovanni

    2009-01-01

    This study provides the first EU-wide reconnaissance of the occurrence of polar organic persistent pollutants in European river waters. More than 100 individual water samples from over 100 European rivers from 27 European Countries were analysed for 35 selected compounds, comprising pharmaceuticals, pesticides, PFOS, PFOA, benzotriazoles, hormones, and endocrine disrupters. Around 40 laboratories participated in this sampling exercise. The most frequently and at the highest concentration levels detected compounds were benzotriazole, caffeine, carbamazepine, tolyltriazole, and nonylphenoxy acetic acid (NPE 1 C). Only about 10% of the river water samples analysed could be classified as 'very clean' in terms of chemical pollution. The rivers responsible for the major aqueous emissions of PFOS and PFOA from the European Continent could be identified. For the target compounds chosen, we are proposing 'indicative warning levels' in surface waters, which are (for most compounds) close to the 90th percentile of all water samples analysed. - More than 100 river water samples from 27 European Countries were analysed for 35 selected polar organic contaminants

  2. EU-wide survey of polar organic persistent pollutants in European river waters

    Energy Technology Data Exchange (ETDEWEB)

    Loos, Robert [European Commission, Joint Research Centre, Institute for Environment and Sustainability, Via Enrico Fermi, 21020 Ispra (Italy)], E-mail: robert.loos@jrc.it; Gawlik, Bernd Manfred; Locoro, Giovanni; Rimaviciute, Erika; Contini, Serafino; Bidoglio, Giovanni [European Commission, Joint Research Centre, Institute for Environment and Sustainability, Via Enrico Fermi, 21020 Ispra (Italy)

    2009-02-15

    This study provides the first EU-wide reconnaissance of the occurrence of polar organic persistent pollutants in European river waters. More than 100 individual water samples from over 100 European rivers from 27 European Countries were analysed for 35 selected compounds, comprising pharmaceuticals, pesticides, PFOS, PFOA, benzotriazoles, hormones, and endocrine disrupters. Around 40 laboratories participated in this sampling exercise. The most frequently and at the highest concentration levels detected compounds were benzotriazole, caffeine, carbamazepine, tolyltriazole, and nonylphenoxy acetic acid (NPE{sub 1}C). Only about 10% of the river water samples analysed could be classified as 'very clean' in terms of chemical pollution. The rivers responsible for the major aqueous emissions of PFOS and PFOA from the European Continent could be identified. For the target compounds chosen, we are proposing 'indicative warning levels' in surface waters, which are (for most compounds) close to the 90th percentile of all water samples analysed. - More than 100 river water samples from 27 European Countries were analysed for 35 selected polar organic contaminants.

  3. Participation in European water policy

    NARCIS (Netherlands)

    J.A. van Ast (Jacko); S.P. Boot (Sander Paul)

    2003-01-01

    textabstractThis paper considers the possibilities for interactive policy-making in European water management. In the new European Water Framework Directive, public information and consultation are major elements in the procedure (process) that leads to River Basin Management Plans. In general,

  4. Sample Transport for a European Sample Curation Facility

    Science.gov (United States)

    Berthoud, L.; Vrublevskis, J. B.; Bennett, A.; Pottage, T.; Bridges, J. C.; Holt, J. M. C.; Dirri, F.; Longobardo, A.; Palomba, E.; Russell, S.; Smith, C.

    2018-04-01

    This work has looked at the recovery of Mars Sample Return capsule once it arrives on Earth. It covers possible landing sites, planetary protection requirements, and transportation from the landing site to a European Sample Curation Facility.

  5. Inorganic chemical quality of European tap-water: 1. Distribution of parameters and regulatory compliance

    International Nuclear Information System (INIS)

    Banks, David; Birke, Manfred; Flem, Belinda; Reimann, Clemens

    2015-01-01

    Highlights: • A pan-European survey comprises >60 inorganic parameters in 579 tap water samples. • Compliance with standards for inorganic parameters is good (>99% in EU states). • Around 1% non-compliance is observed for arsenic and 0.2% for uranium. • No sample of water contained nitrate in excess of 45 mg/L. • A weak co-variation in Cu and Pb could indicate derivation from plumbing. - Abstract: 579 tap water samples were collected at the European scale and analysed in a single laboratory for more than 60 parameters. This dataset is evaluated here in terms of the statistical distribution of the analysed parameters and compliance with EU and international drinking water regulations. For most parameters a 99% (or better) degree of compliance was achieved. Among the parameters with the higher rates of non-compliance are: arsenic (1% non-compliance in EU member states, 1.6% when samples from non-EU states are also considered) and sodium (0.6%/1.0%). The decision by the WHO to raise its provisional guideline from 15 μg/L (WHO, 2004) to 30 μg/L (WHO, 2011) has reduced non-compliance for uranium from 1.0% to 0.2%. Despite the fact that tap water (i.e. presumed treated water) was collected, many observations can still be interpreted in terms of hydrogeochemical processes. The dataset demonstrates the potential value of very cost-effective, low-density sampling approaches at a continental (European) scale

  6. Determination of tributyltin in whole water matrices under the European Water Framework Directive.

    Science.gov (United States)

    Richter, Janine; Fettig, Ina; Philipp, Rosemarie; Jakubowski, Norbert; Panne, Ulrich; Fisicaro, Paola; Alasonati, Enrica

    2016-08-12

    Monitoring of water quality is important to control water pollution. Contamination of the aquatic system has a large effect on human health and the environment. Under the European Water Framework Directive (WFD) 2000/60/EC and the related directive on environmental quality standards (EQS) in the field of water policy 2008/105/EC, the need for sensitive reference methods was highlighted. Since tributyltin (TBT) is one of the WFD listed priority substances a method was developed which is capable to qualify and quantify the pollutant at the required low WFD EQS of 0.2ngL(-1) in whole water bodies, i.e. in non-filtered water samples with dissolved organic carbon and suspended particulate matter. Therefore special attention was paid on the interaction of TBT with the suspended particulate matter and humic substances to obtain a complete representation of the pollution in surface waters. Different water samples were investigated varying the content of organic dissolved and suspended matter. Quantification was performed using species-specific isotope dilution (SSID) and gas chromatography with inductively coupled plasma mass spectrometry (GC-ICP-MS). Different sample treatment strategies were evaluated and compared. The process of internal standard addition was investigated and optimized, hence the equilibrium between internal standards and matrix is of primary importance to perform accurate SSID. Samples spiked at EQS level were analyzed with a recovery between 95 and 105 %. Additionally real surface water samples were investigated and the TBT concentration for the whole water body was determined and compared with conventional routine analysis method. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Inorganic chemical quality of European tap-water: 2. Geographical distribution

    International Nuclear Information System (INIS)

    Flem, B.; Reimann, C.; Birke, M.; Banks, D.; Filzmoser, P.; Frengstad, B.

    2015-01-01

    Highlights: • European scale comparison of tap water. • 579 tap water samples have been analyses for more than 60 parameters. • Chemical geographical distribution. • Water treatment processes. • Importance of geology on tap water quality. - Abstract: 579 tap water samples were collected at the European scale and analysed at a single laboratory for more than 60 parameters. This dataset is analysed here in terms of the spatial and national distribution of the analysed inorganic chemical parameters. The distribution of most parameters is controlled by various artificial and natural factors (land use, distribution network, water source and treatment, geographical location and geology). The distribution of nitrate can be interpreted in terms of land use and climate. Water treatment affects the distribution of phosphorus in tap water; especially the policy of adding phosphate to potable water in the UK to suppress plumbosolvency. The distribution of alkalinity, Ca, Mg, Sr and Li appears to reflect both water source (low in surface waters) and the geological contrast between base-poor crystalline rock terrains and carbonate rich sedimentary rock. The Scandinavian nations’ tap water shows the highest concentrations of most of the rare earth elements, probably reflecting their geological availability and mobility in low pH raw water sources. The distribution of fluoride, uranium and arsenic also appear to exhibit geological and source (groundwater versus surface water) controls. Hungary returns several high As results, which may reflect As-rich reducing groundwaters of the Pannonian basin. Much Estonian tap water reflects a very specific hydrochemical environment, namely Palaeozoic near-coastal aquifers, which yield deep, reducing or saline groundwater (possibly influenced by marine intrusion), enriched in Ba, B, Br − , Cl − , Eu, F − , I, Li, K, Mn and Na

  8. EURO-CARES as Roadmap for a European Sample Curation Facility

    Science.gov (United States)

    Brucato, J. R.; Russell, S.; Smith, C.; Hutzler, A.; Meneghin, A.; Aléon, J.; Bennett, A.; Berthoud, L.; Bridges, J.; Debaille, V.; Ferrière, L.; Folco, L.; Foucher, F.; Franchi, I.; Gounelle, M.; Grady, M.; Leuko, S.; Longobardo, A.; Palomba, E.; Pottage, T.; Rettberg, P.; Vrublevskis, J.; Westall, F.; Zipfel, J.; Euro-Cares Team

    2018-04-01

    EURO-CARES is a three-year multinational project funded under the European Commission Horizon2020 research program to develop a roadmap for a European Extraterrestrial Sample Curation Facility for samples returned from solar system missions.

  9. European supercritical water cooled reactor

    International Nuclear Information System (INIS)

    Schulenberg, T.; Starflinger, J.; Marsault, P.; Bittermann, D.; Maraczy, C.; Laurien, E.; Lycklama a Nijeholt, J.A.; Anglart, H.; Andreani, M.; Ruzickova, M.; Toivonen, A.

    2011-01-01

    Highlights: → The HPLWR reactor design is an example of a supercritical water cooled reactor. → Cladding material tests have started but materials are not yet satisfactory. → Numerical heat transfer predictions are promising but need further validation. → The research project is most suited for nuclear education and training. - Abstract: The High Performance Light Water Reactor (HPLWR), how the European Supercritical Water Cooled Reactor is called, is a pressure vessel type reactor operated with supercritical water at 25 MPa feedwater pressure and 500 o C average core outlet temperature. It is designed and analyzed by a European consortium of 10 partners and 3 active supporters from 8 Euratom member states in the second phase of the HPLWR project. Most emphasis has been laid on a core with a thermal neutron spectrum, consisting of small fuel assemblies in boxes with 40 fuel pins each and a central water box to improve the neutron moderation despite the low coolant density. Peak cladding temperatures of the fuel rods have been minimized by heating up the coolant in three steps with intermediate coolant mixing. The containment design with its safety and residual heat removal systems is based on the latest boiling water reactor concept, but with different passive high pressure coolant injection systems to cause a forced convection through the core. The design concept of the steam cycle is indicating the envisaged efficiency increase to around 44%. Moreover, it provides the constraints to design the components of the balance of the plant. The project is accompanied by numerical studies of heat transfer of supercritical water in fuel assemblies and by material tests of candidate cladding alloys, performed by the consortium and supported by additional tests of the Joint Research Centre of the European Commission. Besides the scientific and technical progress, the HPLWR project turned out to be most successful in training the young generation of nuclear engineers

  10. Towards the review of the European Union Water Framework Directive: Recommendations for more efficient assessment and management of chemical contamination in European surface water resources.

    Science.gov (United States)

    Brack, Werner; Dulio, Valeria; Ågerstrand, Marlene; Allan, Ian; Altenburger, Rolf; Brinkmann, Markus; Bunke, Dirk; Burgess, Robert M; Cousins, Ian; Escher, Beate I; Hernández, Félix J; Hewitt, L Mark; Hilscherová, Klára; Hollender, Juliane; Hollert, Henner; Kase, Robert; Klauer, Bernd; Lindim, Claudia; Herráez, David López; Miège, Cécil; Munthe, John; O'Toole, Simon; Posthuma, Leo; Rüdel, Heinz; Schäfer, Ralf B; Sengl, Manfred; Smedes, Foppe; van de Meent, Dik; van den Brink, Paul J; van Gils, Jos; van Wezel, Annemarie P; Vethaak, A Dick; Vermeirssen, Etienne; von der Ohe, Peter C; Vrana, Branislav

    2017-01-15

    Water is a vital resource for natural ecosystems and human life, and assuring a high quality of water and protecting it from chemical contamination is a major societal goal in the European Union. The Water Framework Directive (WFD) and its daughter directives are the major body of legislation for the protection and sustainable use of European freshwater resources. The practical implementation of the WFD with regard to chemical pollution has faced some challenges. In support of the upcoming WFD review in 2019 the research project SOLUTIONS and the European monitoring network NORMAN has analyzed these challenges, evaluated the state-of-the-art of the science and suggested possible solutions. We give 10 recommendations to improve monitoring and to strengthen comprehensive prioritization, to foster consistent assessment and to support solution-oriented management of surface waters. The integration of effect-based tools, the application of passive sampling for bioaccumulative chemicals and an integrated strategy for prioritization of contaminants, accounting for knowledge gaps, are seen as important approaches to advance monitoring. Including all relevant chemical contaminants in more holistic "chemical status" assessment, using effect-based trigger values to address priority mixtures of chemicals, to better consider historical burdens accumulated in sediments and to use models to fill data gaps are recommended for a consistent assessment of contamination. Solution-oriented management should apply a tiered approach in investigative monitoring to identify toxicity drivers, strengthen consistent legislative frameworks and apply solutions-oriented approaches that explore risk reduction scenarios before and along with risk assessment. Copyright © 2016. Published by Elsevier B.V.

  11. Towards the review of the European Union Water Framework management of chemical contamination in European surface water resources

    NARCIS (Netherlands)

    Brack, Werner; Dulio, Valeria; Ågerstrand, Marlene; Allan, Ian; Altenburger, Rolf; Brinkmann, Markus; Bunke, Dirk; Burgess, Robert M.; Cousins, Ian; Escher, Beate I.; Hernández, Félix J.; Hewitt, L.M.; Hilscherová, Klára; Hollender, Juliane; Hollert, Henner; Kase, Robert; Klauer, Bernd; Lindim, Claudia; Herráez, David López; Miège, Cécil; Munthe, John; O'Toole, Simon; Posthuma, Leo; Rüdel, Heinz; Schäfer, Ralf B.; Sengl, Manfred; Smedes, Foppe; Meent, van de Dik; Brink, van den Paul J.; Gils, van Jos; Wezel, van Annemarie P.; Vethaak, A.D.; Vermeirssen, Etienne; Ohe, von der Peter C.; Vrana, Branislav

    2017-01-01

    Water is a vital resource for natural ecosystems and human life, and assuring a high quality of water and protecting it from chemical contamination is a major societal goal in the European Union. The Water Framework Directive (WFD) and its daughter directives are the major body of legislation for

  12. European Water Footprint Scenarios for 2050

    Directory of Open Access Journals (Sweden)

    A. Ertug Ercin

    2016-05-01

    Full Text Available This study develops water footprint scenarios for Europe for 2050, at the country level, based on projections regarding population and economic growth, production and trade patterns, consumption patterns (diets and bioenergy use and technological development. The objective is to estimate possible future changes in the green, blue and grey water footprint (WF of production and consumption, to analyze the main drivers of projected changes and to assess Europe’s future dependence on water resources elsewhere in the world. We develop four scenarios, considering globalization versus regional self-sufficiency, and development driven by economic objectives versus development driven by social and environmental objectives. The study shows that the most critical driver of change affecting Europe’s future WF is the consumption pattern. The WFs of both production and consumption in Western Europe increase under scenarios with high meat consumption and decrease with low-meat scenarios. Besides, additional water demands from increasing biofuel needs will put further pressure on European water resources. The European countries with a large ratio of external to total WF of consumption in 2000 decrease their dependencies on foreign water resources in 2050.

  13. The Occurrence and Toxicity of Disinfection Byproducts in European Drinking Waters in Relation with the HIWATE Epidemiology Study

    Science.gov (United States)

    Jeong, Clara H.; Wagner, Elizabeth D.; Siebert, Vincent R.; Anduri, Sridevi; Richardson, Susan D.; Daiber, Eric J.; McKague, A. Bruce; Kogevinas, Manolis; Villanueva, Cristina M.; Goslan, Emma H.; Luo, Wentai; Isabelle, Lorne M.; Pankow, James F.; Grazuleviciene, Regina; Cordier, Sylvaine; Edwards, Susan C.; Righi, Elena; Nieuwenhuijsen, Mark J.; Plewa, Michael J.

    2012-01-01

    The HIWATE (Health Impacts of long-term exposure to disinfection byproducts in drinking WATEr) project was a systematic analysis that combined the epidemiology on adverse pregnancy outcomes and other health effects with long term exposure to low levels of drinking water disinfection byproducts (DBPs) in the European Union. The present study focused on the relationship of the occurrence and concentration of DBPs with in vitro mammalian cell toxicity. Eleven drinking water samples were collected from 5 European countries. Each sampling location corresponded with an epidemiological study for the HIWATE program. Over 90 DBPs were identified; the range in the number of DBPs and their levels reflected the diverse collection sites, different disinfection processes, and the different characteristics of the source waters. For each sampling site, chronic mammalian cell cytotoxicity correlated highly with the numbers of DBPs identified and the levels of DBP chemical classes. Although there was a clear difference in the genotoxic responses among the drinking waters, these data did not correlate as well with the chemical analyses. Thus, the agents responsible for the genomic DNA damage observed in the HIWATE samples may be due to unresolved associations of combinations of identified DBPs, unknown emerging DBPs that were not identified, or other toxic water contaminants. This study represents the first to integrate quantitative in vitro toxicological data with analytical chemistry and human epidemiologic outcomes for drinking water DBPs. PMID:22958121

  14. Tributyltin--critical pollutant in whole water samples--development of traceable measurement methods for monitoring under the European Water Framework Directive (WFD) 2000/60/EC.

    Science.gov (United States)

    Richter, Janine; Fettig, Ina; Philipp, Rosemarie; Jakubowski, Norbert

    2015-07-01

    Tributyltin is listed as one of the priority substances in the European Water Framework Directive (WFD). Despite its decreasing input in the environment, it is still present and has to be monitored. In the European Metrology Research Programme project ENV08, a sensitive and reliable analytical method according to the WFD was developed to quantify this environmental pollutant at a very low limit of quantification. With the development of such a primary reference method for tributyltin, the project helped to improve the quality and comparability of monitoring data. An overview of project aims and potential analytical tools is given.

  15. Towards a benchmarking paradigm in European water utilities

    NARCIS (Netherlands)

    Marques, R.C.; de Witte, K.

    2010-01-01

    This article explains the benefits of using benchmarking tools in the public sector to drive up performance. The authors examine the case of European water utilities, focusing on four countries: Portugal, Belgium, The Netherlands and the UK. They argue for the creation of a European ‘observatory’ to

  16. Trace element analysis of mineral water samples by PIXE and ICP-MS

    International Nuclear Information System (INIS)

    Kennedy, V.John; Augusthy, A.; Varier, K. M.; Magudapathy, P.; Panchapakesan, S.; Nair, K.G.M.

    1998-01-01

    Trace elements present in bottled mineral water have been studied by PIXE and ICP-MS. Samples from ten different brands of brands of bottled mineral water were prepared by preconcentration techniques. Measurements were carried out using the 2 MeV proton beam obtained from 3 MV Tandem pelletron accelerator at the Institute of Physics, Bhubaneswar. Our results are compared with Indian standard packaged natural mineral water specifications, World Health Organisation (WHO) and European guidelines for drinking water standards. Concentration of aluminum was found to be more in one of the brands. In general, our results are comparable to the above standards. (author)

  17. Polyfluorinated chemicals in European surface waters, ground- and drinking waters

    NARCIS (Netherlands)

    Eschauzier, C.; de Voogt, P.; Brauch, H.-J.; Lange, F.T.; Knepper, T.P.; Lange, F.T.

    2012-01-01

    Polyfluorinated chemicals (PFCs), especially short chain fluorinated alkyl sulfonates and carboxylates, are ubiquitously found in the environment. This chapter aims at giving an overview of PFC concentrations found in European surface, ground- and drinking waters and their behavior during

  18. Evaluating the quality of sampling frames used in European cross-national surveys

    NARCIS (Netherlands)

    Maineri, A.M.; Scherpenzeel, A.; Bristle, Johanna; Pflüger, Senta-Melissa; Butt, Sarah; Zins, Stefan; Emery, Tom; Luijkx, R.

    This report addresses the quality of the population registers which are currently being used as sampling frames in countries participating in the four cross-European surveys cooperating in SERISS: the European Social Survey (ESS), the European Values Study (EVS), the Gender and Generations Program

  19. Reactor water sampling device

    International Nuclear Information System (INIS)

    Sakamaki, Kazuo.

    1992-01-01

    The present invention concerns a reactor water sampling device for sampling reactor water in an in-core monitor (neutron measuring tube) housing in a BWR type reactor. The upper end portion of a drain pipe of the reactor water sampling device is attached detachably to an in-core monitor flange. A push-up rod is inserted in the drain pipe vertically movably. A sampling vessel and a vacuum pump are connected to the lower end of the drain pipe. A vacuum pump is operated to depressurize the inside of the device and move the push-up rod upwardly. Reactor water in the in-core monitor housing flows between the drain pipe and the push-up rod and flows into the sampling vessel. With such a constitution, reactor water in the in-core monitor housing can be sampled rapidly with neither opening the lid of the reactor pressure vessel nor being in contact with air. Accordingly, operator's exposure dose can be reduced. (I.N.)

  20. European union water policy--tasks for implementing "Water Framework Directive" in pre-accession countries.

    Science.gov (United States)

    Sözen, Seval; Avcioglu, Ebru; Ozabali, Asli; Görgun, Erdem; Orhon, Derin

    2003-08-01

    Water Framework Directive aiming to maintain and improve the aquatic environment in the EU was launched by the European Parliament in 2000. According to this directive, control of quantity is an ancillary element in securing good water quality and therefore measures on quantity, serving the objective of ensuring good quality should also be established. Accordingly, it is a comprehensive and coordinated package that will ensure all European waters to be protected according to a common standard. Therefore, it refers to all other Directives related to water resources management such as Urban Wastewater Treatment Directive Nitrates Directive, Drinking Water Directive, Integrated Pollution Prevention Control etc. Turkey, as a candidate state targeting full-membership, should comply the necessary preparations for the implementation of the "Water Framework Directive" as soon as possible. In this study, the necessary legislative, political, institutional, and technical attempts of the pre-accession countries have been discussed and effective recommendations have been offered for future activities in Turkey.

  1. An Approach for harmonizing European Water Portals

    Science.gov (United States)

    Pesquer, Lluís; Stasch, Christoph; Masó, Joan; Jirka, Simon; Domingo, Xavier; Guitart, Francesc; Turner, Thomas; Hinderk Jürrens, Eike

    2017-04-01

    A number of European funded research projects is developing novel solutions for water monitoring, modeling and management. To generate innovations in the water sector, third parties from industry and the public sector need to take up the solutions and bring them into the market. A variety of portals exists to support this move into the market. Examples on the European level are the EIP Water Online Marketplace(1), the WaterInnEU Marketplace(2), the WISE RTD Water knowledge portal(3), the WIDEST- ICT for Water Observatory(4) or the SWITCH-ON Virtual Product Market and Virtual Water-Science Laboratory(5). Further innovation portals and initiatives exist on the national or regional level, for example, the Denmark knows water platform6 or the Dutch water alliance(7). However, the different portals often cover the same projects, the same products and the same services. Since they are technically separated and have their own data models and databases, people need to duplicate information and maintain it at several endpoints. This requires additional efforts and hinders the interoperable exchange between these portals and tools using the underlying data. In this work, we provide an overview on the existing portals and present an approach for harmonizing and integrating common information that is provided across different portals. The approach aims to integrate the common in formation in a common database utilizing existing vocabularies, where possible. An Application Programming Interface allows access the information in a machine-readable way and utilizing the information in other applications beyond description and discovery purposes. (1) http://www.eip-water.eu/my-market-place (2) https://marketplace.waterinneu.org (3) http://www.wise-rtd.info/ (4) http://iwo.widest.eu (5) http://www.switch-on-vwsl.eu/ (6) http://www.rethinkwater.dk/ (7) http://wateralliance.nl/

  2. European scale climate information services for water use sectors

    NARCIS (Netherlands)

    Vliet, van M.T.H.; Donnelly, Chantal; Strömbäck, Lena; Capell, René; Ludwig, Fulco

    2015-01-01

    This study demonstrates a climate information service for pan-European water use sectors that are vulnerable to climate change induced hydrological changes, including risk and safety (disaster preparedness), agriculture, energy (hydropower and cooling water use for thermoelectric power) and

  3. Comparison of trace metal bioavailabilities in European coastal waters using mussels from Mytilus edulis complex as biomonitors

    NARCIS (Netherlands)

    Przytarska, J.E.; Sokołowski, A.; Wołowicz, M.; Hummel, H.; Jansen, J.M.

    2010-01-01

    Mussels from Mytilus edulis complex were used as biomonitors of the trace metals Fe, Mn, Pb, Zn, and Cu at 17 sampling sites to assess the relative bioavailability of metals in coastal waters around the European continent. Because accumulated metal concentrations in a given area can differ

  4. Impact of the European Water framework directive on knowledge of biodiversity Impact of the European Water framework directive on knowledge of biodiversity

    Directory of Open Access Journals (Sweden)

    Christine Argillier and Mario Lepage

    2011-03-01

    Full Text Available The European Water framework directive requires observation and monitoring of certain biological communities to assess the ecological status of aquatic environments. How does the WFD contribute to knowledge and evaluation of aquatic biodiversity? What may be the results in terms of monitoring?The concept of biodiversity is complex and difficult to describe in an exhaustive manner. The Water Framework Directive (WFD, through its aquatic ecosystem monitoring network, aims to assess the ecological and chemical status of water bodies. This assessment requires observations on certain biological communities in a definite number of European sites representing continental, transitional and coastal water bodies. Consequently, the WFD contributes to improving knowledge on biodiversity. Nevertheless, genetic diversity and some communities are clearly not targeted and the monitoring networks are not well designed to assess changes in biodiversity. However, we may expect improvements in scientific knowledge of ecosystems and in the monitoring programmes that will make possible better convergence of environmental objectives.

  5. European water law in transition: the challenge of integration

    NARCIS (Netherlands)

    Rijswick, H.F.M.W. van

    2005-01-01

    European and domestic national water law have witnessed a number of developments, which can be described as the development from a national territorial approach towards a transnational integrated approach. Initially, Dutch water law for example, sought to offer protection against flooding. More

  6. Towards the review of the European Union Water Framework ...

    Science.gov (United States)

    Water is a vital resource for natural ecosystems and human life, and assuring a high quality of water and protectingit from chemical contamination is a major societal goal in the European Union. The Water Framework Directive(WFD) and its daughter directives are the major body of legislation for the protection and sustainable use of Europeanfreshwater resources. The practical implementation of the WFD with regard to chemical pollution has facedsome challenges. In support of the upcoming WFD review in 2019 the research project SOLUTIONS and the Europeanmonitoring network NORMAN has analyzed these challenges, evaluated the state-of-the-art of the science andsuggested possible solutions. We give 10 recommendations to improve monitoring and to strengthen comprehensiveprioritization, to foster consistent assessment and to support solution-oriented management of surface waters.The integration of effect-based tools, the application of passive sampling for bioaccumulative chemicals and an integratedstrategy for prioritization of contaminants, accounting for knowledge gaps, are seen as important approachesto advance monitoring. Including all relevant chemical contaminants in more holistic “chemical status”assessment, using effect-based trigger values to address priority mixtures of chemicals, to better consider historicalburdens accumulated in sediments and to use models to fill data gaps are recommended for a consistent assessmentof contamination. Solution-oriented m

  7. Developing Water Sampling Standards

    Science.gov (United States)

    Environmental Science and Technology, 1974

    1974-01-01

    Participants in the D-19 symposium on aquatic sampling and measurement for water pollution assessment were informed that determining the extent of waste water stream pollution is not a cut and dry procedure. Topics discussed include field sampling, representative sampling from storm sewers, suggested sampler features and application of improved…

  8. Towards the review of the European Union Water Framework Directive: Recommendations for more efficient assessment and management of chemical contamination in European surface water resources

    Science.gov (United States)

    Water is a vital resource for natural ecosystems and human life, and assuring a high quality of water and protectingit from chemical contamination is a major societal goal in the European Union. The Water Framework Directive(WFD) and its daughter directives are the major body of ...

  9. Development of a water quality index based on a European ...

    African Journals Online (AJOL)

    This index has advantages over pre-existing indices by reflecting the appropriateness of water for specific use, e.g. drinking water supply rather than general supply, and has been developed by studying the supranational standard, i.e. the European Community Standard. Three classification schemes for water quality are ...

  10. Towards the review of the European Union Water Framework Directive: Recommendations for more efficient assessment and management of chemical contamination in European surface water resources

    NARCIS (Netherlands)

    Brack, W.; Dulio, V.; Agerstrand, M.; Allan, I.; Altenburger, R.; Brinkmann, M.; Bunke, D.; Burgess, R.M.; Cousins, I.; Escher, B.I.; Hernandez, F.J.; Hewitt, L.M.; Hilscherova, K.; Hollender, J.; Hollert, H.; Kase, R.; Klauer, B.; Lindim, C.; Herraez, D.L.; Miege, C.; Munthe, J.; O'Toole, S.; Posthuma, L.; Rudel, H.; Schafer, R.B.; Sengl, M.; Smedes, F.; van de Meent, D.; van den Brink, P.J.; van Gils, J.; van Wezel, A.P.; Vethaak, A.D.; Vermeirssen, E.; von der Ohe, P.C.; Vrana, B.

    2017-01-01

    Water is a vital resource for natural ecosystems and human life, and assuring a high quality of water and protecting it from chemical contamination is a major societal goal in the European Union. The Water Framework Directive (WFD) and its daughter directives are the major body of legislation for

  11. European supercritical water cooled reactor (HPLWR Phase 2 project)

    International Nuclear Information System (INIS)

    Schulenberg, Thomas; Starflinger, Joerg; Marsault, Philippe; Bittermann, Dietmar; Maraczy, Czaba; Laurien, Eckart; Lycklama, Jan Aiso; Anglart, Henryk; Andreani, Michele; Ruzickova, Mariana; Heikinheimo, Liisa

    2010-01-01

    The High Performance Light Water Reactor (HPLWR), how the European Supercritical Water Cooled Reactor is called, is a pressure vessel type reactor operated with supercritical water at 25 MPa feedwater pressure and 500 deg C maximum core outlet temperature. It is designed and analyzed by a European consortium of 13 partners from 8 Euratom member states in the second phase of the HPLWR project. Most emphasis has been laid on a core with a thermal neutron spectrum, consisting of small, housed fuel assemblies with 40 fuel pins each and a central water box to improve the neutron moderation despite the low coolant density. Peak cladding temperatures of the fuel rods have been minimized by heating up the coolant in three steps with intermediate coolant mixing. The innovative core design with upward and downward flow through its assemblies has been studied with neutronic, thermal-hydraulic and stress analyses and has been reviewed carefully in a mid-term assessment. The containment design with its safety and residual heat removal systems is based on the latest boiling water reactor concept, but with different passive high pressure coolant injection systems to cause a forced convection through the core. The design concept of the steam cycle is indicating the envisaged efficiency increase to around 44%. Moreover, it provides the constraints to design the components of the balance of the plant. The project is accompanied by numerical studies of heat transfer of supercritical water in fuel assemblies and by material tests of candidate cladding alloys, performed by the consortium and supported by additional tests of the Joint Research Centre of the European Commission. An overview of results achieved up to now, given in this paper, is illustrating the latest scientific and technological advances. (author)

  12. The need for (further) development of water treatment processes against the background of the European water outline regulation

    International Nuclear Information System (INIS)

    Hurst, S.; Boerke, P.; Abo-Rady, M.; Engelmann, U.; Felix, M.

    2005-01-01

    In the German state of Sachsen, large areas have been contaminated by coal, lignite and uranium mining. Pollutants like sulfate, chloride, heavy metals and radionuclides are emitted into groundwater and surface water. Regeneration of the water according to the European Water Directive (EG-WRRL) can be achieved only by (further) development of passive water treatment methods. This means that pollutants, seepage mechanisms and experience so far must be revisited. Exemplary technologies are presented which are low-cost, sustainable and appropriate for the conditions prevailing in Sachsen. Areas that require further investigation are defined, and it is shown how the European water standards may be achieved. (orig.)

  13. Are Lead Exposures a Risk in European Fresh Waters? A Regulatory Assessment Accounting for Bioavailability.

    Science.gov (United States)

    Peters, Adam; Wilson, Iain; Merrington, Graham; Chowdhury, M Jasim

    2018-01-01

    An indicative compliance assessment of the Europe-wide bioavailable lead Environmental Quality Standard of 1.2 µg L -1 (EQS) was undertaken against regulatory freshwater monitoring data from six European member states and FOREGS database. Bio-met, a user-friendly tool based upon Biotic Ligand Models (BLMs) was used to account for bioavailability, along with the current European Water Framework Directive lead dissolved organic carbon correction approach. The outputs from both approaches were compared to the BLM. Of the 9054 freshwater samples assessed only 0.6% exceeded the EQS of 1.2 µg L -1 after accounting for bioavailability. The data showed that ambient background concentrations of lead across Europe are unlikely to influence general compliance with the EQS, although there may be isolated local issues. The waters showing the greatest sensitivity to potential lead exposures are characterized by relatively low DOC (< 0.5 mg L -1 ), regardless of the pH and calcium concentrations.

  14. The radiological exposure of the population of the European Community from radioactivity in North European marine waters Project 'Marina'

    International Nuclear Information System (INIS)

    1990-01-01

    Project Marina was set up by the Commission of the European Communities in 1985 to look at the radiological impact of radionuclides, both natural and anthropogenic, in northern European marine waters. This paper is a summary of project Marina's work and its conclusions

  15. Evaluation of the toxicological properties of ground- and surface-water samples from the Aral Sea Basin

    International Nuclear Information System (INIS)

    Bosch, K.; Erdinger, L.; Ingel, F.; Khussainova, S.; Utegenova, E.; Bresgen, N.; Eckl, P.M.

    2007-01-01

    In order to determine whether there is a potential health risk associated with the water supply in the Aral Sea Basin, ground- and surface-water samples were collected in and around Aralsk and from the Aral Sea in 2002. Water samples from Akchi, a small town close to Almaty, served as controls. Bioassays with different toxicological endpoints were employed to assess the general toxicological status. Additionally, the samples were analysed for microbial contamination. The samples were tested in the primary hepatocyte assay for their potential to induce micronuclei and chromosomal aberrations as cumulative indicators for genotoxicity. In parallel, the effects on cell proliferation evidenced by mitotic index and cytotoxicity such as the appearance of necrotic and apoptotic cells, were determined. Furthermore, samples were examined using the Microtox assay for general toxicity. Chemical analysis according to European regulations was performed and soil and water samples were analysed for DDT and DDE. The results obtained indicated no increased cyto- or genotoxic potential of the water samples, nor levels of DDT or DDE exceeding the thresholds levels suggested by WHO. Our data therefore do not support the hypothesis that the contamination of the drinking water in and around Aralsk is responsible for the health effects previously described such as increased rates of liver disease and in particular liver cancer. Microbiological analysis, however, revealed the presence of contamination in most samples analysed

  16. The European water framework directive: A challenge for nearshore, coastal and continental shelf research

    Science.gov (United States)

    Borja, Ángel

    2005-09-01

    The European Water Framework Directive (WFD) establishes a framework for the protection of groundwater, inland surface waters, estuarine waters, and coastal waters. The WFD constitutes a new view of the water resources management in Europe because, for the first time, water management is: (i) based mainly upon biological and ecological elements, with ecosystems being at the centre of the management decisions; (ii) applied to European water bodies, as a whole; and (iii) based upon the whole river basin, including also the adjacent coastal area. Although the marine water bodies affected by the WFD relate to only 19.8% of the whole of the European continental shelf, its application constitutes a challenge and an opportunity in nearshore, coastal and continental shelf research. This contribution highlights some of the main tasks and the research to be undertaken in the coming years, proposing investigations into: typologies; physico-chemical processes; indicator species; reference conditions; integration of the quality assessment; methodologies in determining ecological status, etc.

  17. European landscape architecture and territorial strategies for water landscapes

    DEFF Research Database (Denmark)

    Diedrich, Lisa Babette

    2010-01-01

    This article sums up the author’s lecture at the 2009 Sydney Resilient Water Landscapes Symposium and presents a series of realized or planned European landscape architectural and urbanistic projects on water landscapes taken from the recently published book On Site/ Landscape Architecture Europe...... and accompanying reflections. The hypothesis is that further scientific research can help defining weaknesses and strengths of the existing water landscape designs in terms of resilience, extract principles and tools, improve the weak ones and communicate the strong ones and develop general quality criteria...... and tools for future resilient water landscapes....

  18. Peer Effects on Obesity in a Sample of European Children

    DEFF Research Database (Denmark)

    Gwozdz, Wencke; Sousa-Poza, Alfonso; Reisch, Lucia A.

    2015-01-01

    This study analyzes peer effects on childhood obesity using data from the first two waves of the IDEFICS study, which applies several anthropometric and other measures of fatness to approximately 14,000 children aged two to nine participating in both waves in 16 regions of eight European countries....... Peers are defined as same-sex children in the same school and age group. The results show that peer effects do exist in this European sample but that they differ among both regions and different fatness measures. Peer effects are larger in Spain, Italy, and Cyprus – the more collectivist regions in our...... sample – while waist circumference generally gives rise to larger peer effects than BMI. We also provide evidence that parental misperceptions of their own children's weight goes hand in hand with fatter peer groups, supporting the notion that in making such assessments, parents compare their children...

  19. Spatial and seasonal variation in diversity and structure of microbial biofilms on marine plastics in Northern European waters.

    Science.gov (United States)

    Oberbeckmann, Sonja; Loeder, Martin G J; Gerdts, Gunnar; Osborn, A Mark

    2014-11-01

    Plastic pollution is now recognised as a major threat to marine environments and marine biota. Recent research highlights that diverse microbial species are found to colonise plastic surfaces (the plastisphere) within marine waters. Here, we investigate how the structure and diversity of marine plastisphere microbial community vary with respect to season, location and plastic substrate type. We performed a 6-week exposure experiment with polyethylene terephthalate (PET) bottles in the North Sea (UK) as well as sea surface sampling of plastic polymers in Northern European waters. Scanning electron microscopy revealed diverse plastisphere communities comprising prokaryotic and eukaryotic microorganisms. Denaturing gradient gel electrophoresis (DGGE) and sequencing analysis revealed that plastisphere microbial communities on PET fragments varied both with season and location and comprised of bacteria belonging to Bacteroidetes, Proteobacteria, Cyanobacteria and members of the eukaryotes Bacillariophyceae and Phaeophyceae. Polymers sampled from the sea surface mainly comprised polyethylene, polystyrene and polypropylene particles. Variation within plastisphere communities on different polymer types was observed, but communities were primarily dominated by Cyanobacteria. This research reveals that the composition of plastisphere microbial communities in marine waters varies with season, geographical location and plastic substrate type. © 2014 Federation of European Microbiological Societies. Published by John Wiley & Sons Ltd. All rights reserved.

  20. Water born pollutants sampling using porous suction samples

    International Nuclear Information System (INIS)

    Baig, M.A.

    1997-01-01

    The common standard method of sampling water born pollutants in the vadoze zone is core sampling and it is followed by extraction of pore fluid. This method does not allow sampling at the same location next time and again later on. There is an alternative approach for sampling fluids (water born pollutants) from both saturated and unsaturated regions of vadose zone using porous suction samplers. There are three types of porous suction samplers, vacuum-operated, pressure-vacuum lysimeters, high pressure vacuum samples. The suction samples are operated in the range of 0-70 centi bars and usually consist of ceramic and polytetrafluorethylene (PTFE). The operation range of PTFE is higher than ceramic cups. These samplers are well suited for in situ and repeated sampling form the same location. This paper discusses the physical properties and operating condition of such samplers to the utilized under our environmental sampling. (author)

  1. The European pressurized water reactor

    International Nuclear Information System (INIS)

    Leny, J.C.

    1993-01-01

    The present state of development of the European Pressurized Water Reactor (EPR) is outlined. During the so-called harmonization phase, the French and German utilities drew up their common requirements and evaluated the reactor concept developed until then with respect to these requirements. A main result of the harmonization phase was the issue, in September 1993, of the 'EPR Conceptual Safety Feature Review File' to be jointly assessed by the safety authorities in France and Germany. The safety objectives to be met by the EPR are specified in the second part of the paper, and some details of the primary and secondary side safety systems are given. (orig.) [de

  2. Managed aquifer recharge with reclaimed water: approaches to a European guidance framework.

    Science.gov (United States)

    Hochstrat, R; Wintgens, T; Kazner, C; Jeffrey, P; Jefferson, B; Melin, T

    2010-01-01

    Managed Aquifer Recharge (MAR) with reclaimed water plays a particular role in water stress mitigation, due to both the large potential benefits achieved in terms of sustainable water resources management as well as the complexity of the planning and implementation. This paper focuses on the role of policy in establishing water quality related legal frameworks that are crucial for MAR development. It analyses and compares the current practice of shaping boundary conditions, particularly in a European context but with some international comparison. The work reports on the legal aspects considered most relevant for MAR in the European Union and summarises issues addressed in aquifer recharge regulations and guidelines. Some potential actions are proposed to develop a suitable guidance framework for further exploitation of MAR benefits.

  3. A Comparison of Soil-Water Sampling Techniques

    Science.gov (United States)

    Tindall, J. A.; Figueroa-Johnson, M.; Friedel, M. J.

    2007-12-01

    The representativeness of soil pore water extracted by suction lysimeters in ground-water monitoring studies is a problem that often confounds interpretation of measured data. Current soil water sampling techniques cannot identify the soil volume from which a pore water sample is extracted, neither macroscopic, microscopic, or preferential flowpath. This research was undertaken to compare values of extracted suction lysimeters samples from intact soil cores with samples obtained by the direct extraction methods to determine what portion of soil pore water is sampled by each method. Intact soil cores (30 centimeter (cm) diameter by 40 cm height) were extracted from two different sites - a sandy soil near Altamonte Springs, Florida and a clayey soil near Centralia in Boone County, Missouri. Isotopically labeled water (O18? - analyzed by mass spectrometry) and bromide concentrations (KBr- - measured using ion chromatography) from water samples taken by suction lysimeters was compared with samples obtained by direct extraction methods of centrifugation and azeotropic distillation. Water samples collected by direct extraction were about 0.25 ? more negative (depleted) than that collected by suction lysimeter values from a sandy soil and about 2-7 ? more negative from a well structured clayey soil. Results indicate that the majority of soil water in well-structured soil is strongly bound to soil grain surfaces and is not easily sampled by suction lysimeters. In cases where a sufficient volume of water has passed through the soil profile and displaced previous pore water, suction lysimeters will collect a representative sample of soil pore water from the sampled depth interval. It is suggested that for stable isotope studies monitoring precipitation and soil water, suction lysimeter should be installed at shallow depths (10 cm). Samples should also be coordinated with precipitation events. The data also indicate that each extraction method be use to sample a different

  4. Investigative studies on water contamination in Bangladesh. Primary treatment of water samples at the sampling site

    International Nuclear Information System (INIS)

    Sera, K.; Islam, Md. Shafiqul; Takatsuji, T.; Nakamura, T.; Goto, S.; Takahashi, C.; Saitoh, Y.

    2010-01-01

    Arsenic concentration in 13 well waters, 9 pond waters, 10 agricultural waters and a coconut juice taken in Comilla district, Bangladesh, where the problem of arsenic pollution is the most severe, was investigated. High-level arsenic is detected even in the well water which has been kept drinking by the people. Relatively high arsenic concentration was detected for some pond and farm waters even though the sampling was performed just after the rainy season and the waters were expected to be highly diluted. Clear relationship was observed in elemental compositions between the pond water and the coconut juice collected at the edge of the water. These results are expected to become the basic information for evaluating the risk of individual food such as cultured fishes, shrimps and farm products, and for controlling total intakes of arsenic. In order to solve the problem of transportation of water samples internationally, a simple method of target preparation performed at the sampling site was established and its validity was confirmed. All targets were prepared at the sampling sites in this study on the basis of this method. (author)

  5. Recovery of acidified European surface waters

    Czech Academy of Sciences Publication Activity Database

    Wright, R. F.; Larssen, T.; Camarero, L.; Cosby, B. J.; Ferrier, R. C.; Helliwell, R.; Forsius, M.; Jenkins, A.; Kopáček, Jiří; Majer, V.; Moldan, F.; Posch, M.; Rogora, M.; Schöpp, W.

    2005-01-01

    Roč. 39, č. 3 (2005), 64A-72A ISSN 0013-936X. [ Acid Rain 2005. International Conference on Acid Deposition /7./. Prague, 12.06.2005-17.06.2005] Grant - others:EC(XE) EMERGE EVK1-CT-1999-00032; EC(XE) RECOVER:2010 EVK1-CT-1999-00018; DEFRA(GB) EPG 1/3/194; ICST(ES) REN2000-0889/GLO Institutional research plan: CEZ:AV0Z60170517 Keywords : acid ification * recovery * European lake districts Subject RIV: DJ - Water Pollution ; Quality Impact factor: 4.054, year: 2005

  6. The implications of economic development, climate change and European Water Policy on surface water quality threats

    Directory of Open Access Journals (Sweden)

    Jolanta Dąbrowska

    2017-06-01

    Full Text Available The paper presents historical background, up-to-date situation and future perspectives for the development of nutrient pollution threats to European surface water quality, as well as the evolution of the approach to water pollution. Utilized agricultural area in European countries is slightly diminishing, however the consumption of mineral fertilisers is steadily increasing. The consumption in Europe in the years 2015–2030 is projected to increase by 10%, and in the world by 20%. Both climate changes leading to the increase of temperature even of ca. 6°C (in comparison to the pre-industrial period and accelerated soil erosion due to high intensity rainfall cause increased productivity of water ecosystems. Those aspects have to be taken into consideration in water management. Due to legal regulations introduced in the last twenty years, wastewater treatment has been made more effective and population connected to wastewater treatment systems has increased. The improvement has been seen mainly in eastern and southern parts of Europe. After the implementation of Water Framework Directive theories regarding modern water management have been developed, with the aim to increase the ecosystem’s capacity and its resilience to climate changes and anthropopressure.

  7. Water chemistry control practices and data of the European BWR fleet

    International Nuclear Information System (INIS)

    Stellwag, B.; Laendner, A.; Weiss, S.; Huettner, F.

    2010-01-01

    Nineteen BWR plants are in operation in Europe, nine built by ASEA Atom, six by Siemens KWU and four by General Electric. This paper gives an overview of water chemistry operation practices and parameters of the European BWR plants. General design characteristics of the plants are described. Chemistry control strategies and underlying water chemistry guidelines are summarized. Chemistry data are presented and discussed with regard to plant design characteristics. The paper is based on a contract of the European BWR Forum with AREVA on a chemistry sourcebook for member plants. The survey of chemistry data was conducted for the years 2002 to 2008. (author)

  8. Sources of variability in the determination by evaporation method of gross alpha activity in water samples

    Energy Technology Data Exchange (ETDEWEB)

    Baeza, A.; Corbacho, J.A. [LARUEX, Caceres (Spain). Environmental Radioactivity Lab.

    2013-07-01

    Determining the gross alpha activity concentration of water samples is one way to screen for waters whose radionuclide content is so high that its consumption could imply surpassing the Total Indicative Dose as defined in European Directive 98/83/EC. One of the most commonly used methods to prepare the sources to measure gross alpha activity in water samples is desiccation. Its main advantages are the simplicity of the procedure, the low cost of source preparation, and the possibility of simultaneously determining the gross beta activity. The preparation of the source, the construction of the calibration curves, and the measurement procedure itself involve, however, various factors that may introduce sufficient variability into the results to significantly affect the screening process. We here identify the main sources of this variability, and propose specific procedures to follow in the desiccation process that will reduce the uncertainties, and ensure that the result is indeed representative of the sum of the activities of the alpha emitters present in the sample. (orig.)

  9. Radon measurement in Malaysia water samples

    International Nuclear Information System (INIS)

    Ibrahim, A.B.; Rosli Mahat; Yusof Md Amin

    1995-01-01

    This paper reported the results of the measurement of radon in local water. The water samples collected were rainwater, river water, seawater, well water or ground water at area of State of Selangor and Kuala Lumpur. The samples were collected in scintillation cell ZnS(Ag) through Radon Degassing Unit RDU 200. Alpha activity was counted with scintillation counters RD 200 at energy 5.5 MeV. (author)

  10. ENVIRONMENTAL MANAGEMENT OF MINE WATER, CONSIDERING EUROPEAN WATER LEGISLATION. CASE STUDY OF MEGALOPOLIS MINES

    OpenAIRE

    Dimitrakopoulos, D.; Vassiliou, E.; Tsangaratos, P.; Ilia, I.

    2017-01-01

    Mining activities causes many environmental problems to the surrounding areas, as other industrial activities do also. However mine water pollution, is considered a tough task to handle, as it requires specific regulations, quite distinct from those applicable to most other industrial processes. Even though there are several federal laws and regulations in Greece and in the European Union that influences the mining industry and mine water management, still certain factors complicates their im...

  11. Water sampling techniques for continuous monitoring of pesticides in water

    Directory of Open Access Journals (Sweden)

    Šunjka Dragana

    2017-01-01

    Full Text Available Good ecological and chemical status of water represents the most important aim of the Water Framework Directive 2000/60/EC, which implies respect of water quality standards at the level of entire river basin (2008/105/EC and 2013/39/EC. This especially refers to the control of pesticide residues in surface waters. In order to achieve the set goals, a continuous monitoring program that should provide a comprehensive and interrelated overview of water status should be implemented. However, it demands the use of appropriate analysis techniques. Until now, the procedure for sampling and quantification of residual pesticide quantities in aquatic environment was based on the use of traditional sampling techniques that imply periodical collecting of individual samples. However, this type of sampling provides only a snapshot of the situation in regard to the presence of pollutants in water. As an alternative, the technique of passive sampling of pollutants in water, including pesticides has been introduced. Different samplers are available for pesticide sampling in surface water, depending on compounds. The technique itself is based on keeping a device in water over a longer period of time which varies from several days to several weeks, depending on the kind of compound. In this manner, the average concentrations of pollutants dissolved in water during a time period (time-weighted average concentrations, TWA are obtained, which enables monitoring of trends in areal and seasonal variations. The use of these techniques also leads to an increase in sensitivity of analytical methods, considering that pre-concentration of analytes takes place within the sorption medium. However, the use of these techniques for determination of pesticide concentrations in real water environments requires calibration studies for the estimation of sampling rates (Rs. Rs is a volume of water per time, calculated as the product of overall mass transfer coefficient and area of

  12. Biomass and abundance biases in European standard gillnet sampling

    Czech Academy of Sciences Publication Activity Database

    Šmejkal, Marek; Ricard, Daniel; Prchalová, Marie; Říha, Milan; Muška, Milan; Blabolil, Petr; Čech, Martin; Vašek, Mojmír; Jůza, Tomáš; Herreras, A.M.; Encina, L.; Peterka, Jiří; Kubečka, Jan

    2015-01-01

    Roč. 10, č. 3 (2015), e0122437 E-ISSN 1932-6203 R&D Projects: GA MŠk(CZ) EE2.3.20.0204; GA ČR(CZ) GPP505/12/P647; GA MŠk(CZ) EE2.3.30.0032 Institutional support: RVO:60077344 Keywords : fish sampling * gillnets * large meshes * mesh size selectivity * Improvement of European standard EN 14757 * bream (Abramis brama) Subject RIV: GL - Fishing Impact factor: 3.057, year: 2015

  13. Water constraints on European power supply under climate change: impacts on electricity prices

    NARCIS (Netherlands)

    Vliet, van M.T.H.; Vögele, S.; Rübbelke, D.

    2013-01-01

    Recent warm, dry summers showed the vulnerability of the European power sector to low water availability and high river temperatures. Climate change is likely to impact electricity supply, in terms of both water availability for hydropower generation and cooling water usage for thermoelectric power

  14. Simulated oxygen isotopes in cave drip water and speleothem calcite in European caves

    Directory of Open Access Journals (Sweden)

    A. Wackerbarth

    2012-11-01

    Full Text Available Interpreting stable oxygen isotope (δ18O records from stalagmites is still one of the complex tasks in speleothem research. Here, we present a novel model-based approach, where we force a model describing the processes and modifications of δ18O from rain water to speleothem calcite (Oxygen isotope Drip water and Stalagmite Model – ODSM with the results of a state-of-the-art atmospheric general circulation model enhanced by explicit isotope diagnostics (ECHAM5-wiso. The approach is neither climate nor cave-specific and allows an integrated assessment of the influence of different varying climate variables, e.g. temperature and precipitation amount, on the isotopic composition of drip water and speleothem calcite.

    First, we apply and evaluate this new approach under present-day climate conditions using observational data from seven caves from different geographical regions in Europe. Each of these caves provides measured δ18O values of drip water and speleothem calcite to which we compare our simulated isotope values. For six of the seven caves modeled δ18O values of drip water and speleothem calcite are in good agreement with observed values. The mismatch of the remaining caves might be caused by the complexity of the cave system, beyond the parameterizations included in our cave model.

    We then examine the response of the cave system to mid-Holocene (6000 yr before present, 6 ka climate conditions by forcing the ODSM with ECHAM5-wiso results from 6 ka simulations. For a set of twelve European caves, we compare the modeled mid-Holocene-to-modern difference in speleothem calcite δ18O to available measurements. We show that the general European changes are simulated well. However, local discrepancies are found, and might be explained either by a too low model resolution, complex local soil-atmosphere interactions affecting evapotranspiration or by cave specific factors

  15. Energy efficiency in the European water industry. A compendium of best practices and case studies

    Energy Technology Data Exchange (ETDEWEB)

    Frijns, J. [Watercycle Research Institute KWR, Nieuwegein (Netherlands); Uijterlinde, C. [Foundation for Applied Water Research STOWA, Amersfoort (Netherlands)

    2010-02-15

    This European report on best practices of energy efficiency in the water industry showcases 23 energy efficiency initiatives which were collected as case studies from European water utilities. The 25 case studies presented in this report will be submitted to UKWIR and Black and Veatch, for potential inclusion in the Global Water Research Coalition (GWRC) global compendium of best practice case studies. The aim of the GWRC-compendium is to identify the promising developments and future opportunities to help deliver incremental improvements in energy efficiency through optimisation of existing assets and operations. But also more substantial improvements in energy efficiency from the adoption of novel (but proven at full scale) technologies. The European report describes case studies from: Belgium, Denmark, France, Germany, Hungary, Netherlands, Norway, Spain and Switzerland. Black and Veatch has gathered furthermore information on 47 cases from the UK. These are reported separately and are not included in this European overview.

  16. Natural Water Retention Measures (NWRM): from Design to Implementation through European Projects

    International Nuclear Information System (INIS)

    Magdaleno Mas, F.; Dalacamara Andres, G.

    2015-01-01

    The Centre for Applied Technique Studies (CETA) of CEDEX has been working over the last few years in different European projects related with the design and development of natural water retention measures (NWRM). These are a number of measures, boosted by the Water Unit of the Environment Directorate-General of the European Commission. with close links to green infrastructures, which try to integrate, from a multifunctional approach, different legal and technical requirements aimed at a better adaptation to extreme hydro meteorological events, environmental protection and conservation, and maintenance of ecosystem services. This paper reviews the underpinning foundations of the concept and the mechanisms for designing and implementing NWRM. It also shows the way they can be applied, by presenting different initiatives developed by CETA since 2008 in Navarra (Arga-Aragon rivers system). For fulfilling those works, CETA has collaborated with environmental and hydraulic authorities of Navarra. It has also actively cooperated with research centres, such as the Institute IMDEA Water. specifically in a European project devoted to the diffusion, assessment, and presentation of NWRM within the context of the EU River Basin Districts. (Author)

  17. Transboundary river basin management in Europe
    Legal instruments to comply with European water management obligations in case of transboundary water pollution and floods

    Directory of Open Access Journals (Sweden)

    Andrea M. Keessen

    2008-12-01

    Full Text Available Although modern European water policy follows a river basin approach where Member States have to cooperate in order to achieve a ‘good status’ of their water bodies, the obligations arising from the European water directives are to be achieved by each Member State individually. This situation creates problems when water pollution and water quantity problems cross borders. It is still unclear whether Member States can be held responsible for not achieving objectives due to causes (partly originating abroad. This article describes some of the legal instruments that water authorities have at their disposal to comply with the European water management obligations in case of transboundary water pollution and floods and thus shape transboundary river management. The article describes instruments to create, implement and enforce transboundary cooperation, and addresses the possibility of transboundary compensation if cooperation fails. Here, the focus is on a civil lawsuit before a domestic court.

  18. Results of environmental radioactivity measurements in the Member States of the European Community for air - deposition - water - milk. 1981

    International Nuclear Information System (INIS)

    1983-01-01

    This is the 21st report on ambient radioactivity published by the Health and Safety Directorate of the Commission of the European Communities. It was drawn up using the data collected by stations responsible for environmental radioactivity monitoring in Member States. The results are extracts from the data sent to the Commission under Article 36 of the Treaty of Rome establishing the European Atomic Energy Community. The results presented in this report deal with radioactivity of the air, deposition, surface water and milk during 1981 in the ten Member States of the European Community, viz. Belgium, Denmark, Federal Republic of Germany, Greece, France, Ireland, Italy, Luxembourg, the Netherlands and the United Kingdom. The results are presented under four main headings: artificial radioactivity in the air at ground level; artificial radioactivity in deposition; radioactivity of water; radioactivity of milk. The report also contains the list of sampling stations and laboratories, together with a list of publications by Member States in this field. This report places special emphasis on the measurement results for specific radionuclides, but it also contains data on total beta activity so as to ensure continuity vis-a-vis previous and provide comparative values

  19. Free water {sup 3}H concentration in diet samples collected during 1969-88 in Akita, Japan

    Energy Technology Data Exchange (ETDEWEB)

    Hisamatsu, S. [Institute for Environmental Sciences, Rokkasho, Aomori (Japan); Inoue, Y.; Miyamoto, K. [National Inst. of Radiological Sciences, Chiba (Japan); Takizawa, Y. [National Institute for Minamata Disease, Minamata, Kumamoto (Japan)

    2000-05-01

    Fallout {sup 3}H concentrations in diet samples collected during 1969-88 in Akita Prefecture are reported in this paper. Since {sup 3}H is a potential nuclear fuel for fusion reactors in future, its environmental behavior is important for dose assessment of released {sup 3}H from the plants. Tritium in foods is classified into two types; free water {sup 3}H (FWT) and organically-bound {sup 3}H (OBT). The FWT is practically separated by means of freeze-drying, while the OBT is measured with water sample collected by combustion of dried sample. The OBT concentrations in foods and human tissue samples were reported for {sup 3}H originating from nuclear weapon fallout. We already published {sup 3}H concentrations in diet samples collected in Akita City during 1985-88. Although results for the samples collected in U.S.A. and European countries in the 1970s showed higher specific activity of OBT than FWT, our recent results in Japan indicate almost the same specific activity between them. Since the measurements for the samples in 1960s and 1970s are important to understand the long-term movement of {sup 3}H in the environment, we have searched old diet samples. Recently, diet samples collected in Akita Prefecture during 1969-80 were found and obtained for {sup 3}H analysis. The samples were originally gathered for nutrition survey programs and consisted of duplicate diet samples for 1 day from 10-30 persons. Food samples excluding boiled rice which is the staple food was homogenized by electric mixers after adding tap water. Then, the food and the boiled rice samples were stored in a refrigerator at -20degC. Free water in the samples was collected with lyophilization, then {sup 3}H in the water sample was measured after purification with low-level liquid scintillation counters. The free water {sup 3}H concentrations were measured for 57 diet samples (dish excluding boiled rice) and 17 boiled rice samples. The free water {sup 3}H concentrations in diet and rice samples

  20. Constructing a Strategic, National Resource: European Policies and the Up-Scaling of Water Services in the Algarve, Portugal

    Science.gov (United States)

    Thiel, Andreas

    2010-07-01

    Water management has been significantly reshaped throughout recent decades in Europe and worldwide. Vivid examples of this restructuring include Southern European coastal zones which have been transformed into the European “pleasure periphery” over the last 40 years, requiring significant changes in water service provision. Taking it as an illustrative case of the Southern European coastal freshwater crisis and the way different European Member States have dealt with it, the article provides an account of the Algarve, indicative of typical Portuguese dynamics, and compares it with developments in other European countries. Expanding demands on water services in this region led to a crisis situation throughout the nineties, which was resolved by shifting physical infrastructures and competencies to the supra-local level. The re-scaling of water management was instrumental to expanding national control over the sector at the expense of local authorities and privatization. The national level used European funds and regulations to re-configure the institutional and infrastructure set-up in order to provide for tourism and agricultural expansion. Quality tourism was constructed as a decentral, hegemonic state spatial project, with the Algarvian’s entire water resource base being put at its disposal. The solution found illustrates a modified version of the supply side and surface water oriented “hydraulic paradigm” in Portugal: geared towards tourism and urban areas and the maintenance of irrigation agriculture. Delays in infrastructures, ideological preferences, maintaining national control over strategic water services and territoriality contributed towards the construction of water services as part of this hegemonic state spatial strategy for tourism expansion.

  1. New priority substances of the European Water Framework Directive: biocides, pesticides and brominated flame retardants in the aquatic environment of Denmark.

    Science.gov (United States)

    Vorkamp, Katrin; Bossi, Rossana; Bester, Kai; Bollmann, Ulla E; Boutrup, Susanne

    2014-02-01

    The biocides cybutryn (Irgarol) and terbutryn, the herbicides aclonifen and bifenox, the insecticides cypermethrin and heptachlor/heptachlor epoxide and the brominated flame retardant hexabromocyclododecane (HBCD) are new priority substances of the Water Framework Directive of the European Union. In order to gain knowledge about their presence in the aquatic environment in an off-season situation with regard to pesticide and biocide applications, these substances were analysed in freshwater, seawater and fish samples from Denmark. Aclonifen, bifenox, cypermethrin and heptachlor were below the limits of detection (LODs) in all samples. However, the LODs for cypermethrin and heptachlor exceeded the annual average environmental quality standards (AA-EQSs). Cybutryn, terbutryn, heptachlor epoxide and HBCD were detected in the majority of samples, with detection frequencies of 100% for heptachlor epoxide and HBCD in water and 90% in fish. No concentration was above maximum allowable concentration (MAC)-EQS values, but AA-EQS values were exceeded for all four compounds by several samples, including 100% of the water samples with regard to heptachlor epoxide. Methodological issues remain for cypermethrin, and to a certain extent for heptachlor/heptachlor epoxide, for which water LODs were above AA-EQSs although a water volume of 12L was combined with very sensitive high resolution mass spectrometry. © 2013.

  2. Strategies for monitoring the emerging polar organic contaminants in water with emphasis on integrative passive sampling.

    Science.gov (United States)

    Söderström, Hanna; Lindberg, Richard H; Fick, Jerker

    2009-01-16

    Although polar organic contaminants (POCs) such as pharmaceuticals are considered as some of today's most emerging contaminants few of them are regulated or included in on-going monitoring programs. However, the growing concern among the public and researchers together with the new legislature within the European Union, the registration, evaluation and authorisation of chemicals (REACH) system will increase the future need of simple, low cost strategies for monitoring and risk assessment of POCs in aquatic environments. In this article, we overview the advantages and shortcomings of traditional and novel sampling techniques available for monitoring the emerging POCs in water. The benefits and drawbacks of using active and biological sampling were discussed and the principles of organic passive samplers (PS) presented. A detailed overview of type of polar organic PS available, and their classes of target compounds and field of applications were given, and the considerations involved in using them such as environmental effects and quality control were discussed. The usefulness of biological sampling of POCs in water was found to be limited. Polar organic PS was considered to be the only available, but nevertheless, an efficient alternative to active water sampling due to its simplicity, low cost, no need of power supply or maintenance, and the ability of collecting time-integrative samples with one sample collection. However, the polar organic PS need to be further developed before they can be used as standard in water quality monitoring programs.

  3. First Record of Anisakis simplex Third-Stage Larvae (Nematoda, Anisakidae in European Hake Merluccius merluccius lessepsianus in Egyptian Water

    Directory of Open Access Journals (Sweden)

    Yasmin Abou-Rahma

    2016-01-01

    Full Text Available The prevalence of infection and the identification of anisakid larvae in European hake Merluccius merluccius lessepsianus from Hurghada City, Red Sea Governorate, Egypt, were investigated. Fish samples were collected during the period of February and November 2014. Twenty-two (36.66% out of sixty examined fish specimens were found to be naturally infected with Anisakis type I larvae mostly found as encapsulated larvae in visceral organs. There was a positive relationship between host length/weight and prevalence of infection. Based on morphological, morphometric, and molecular analyses, these nematodes were identified as third-stage larvae of Anisakis simplex. The present study was considered as the first report of anisakid larvae from European hake in the Egyptian water.

  4. First Record of Anisakis simplex Third-Stage Larvae (Nematoda, Anisakidae) in European Hake Merluccius merluccius lessepsianus in Egyptian Water

    Science.gov (United States)

    Abou-Rahma, Yasmin; Abdel-Gaber, Rewaida; Kamal Ahmed, Amira

    2016-01-01

    The prevalence of infection and the identification of anisakid larvae in European hake Merluccius merluccius lessepsianus from Hurghada City, Red Sea Governorate, Egypt, were investigated. Fish samples were collected during the period of February and November 2014. Twenty-two (36.66%) out of sixty examined fish specimens were found to be naturally infected with Anisakis type I larvae mostly found as encapsulated larvae in visceral organs. There was a positive relationship between host length/weight and prevalence of infection. Based on morphological, morphometric, and molecular analyses, these nematodes were identified as third-stage larvae of Anisakis simplex. The present study was considered as the first report of anisakid larvae from European hake in the Egyptian water. PMID:26925257

  5. Inventing a paradigm of piped water: the evolution of urban water concessions on the European continent, 1800-1970

    NARCIS (Netherlands)

    Braadbaart, O.D.

    2007-01-01

    European foundries master the art of mass-producing cast iron pipes in the early 1800s (Cast Iron Soil Pipe Institute 2006:1). Slow sand filters, buried pipes with bell and spigot joints, steam powered pumps, and water towers make for a universally applicable technology for urban water supply. Piped

  6. Water sampling device for fuel rod failure monitoring

    International Nuclear Information System (INIS)

    Oogami, Hideaki; Echigoya, Hironori; Matsuoka, Tesshi.

    1991-01-01

    The device of the present invention accurately samples coolants in a channel box as sampling water even if the upper end of the channel box of a fuel assembly is positioned at the same height or lower than the upper end of an upper lattice plate. An existent device comprises an outer cap, an inner cap, an air supply pipe and a water sampling tube. In addition, the device of the present invention comprises a sealing material disposed at the end of the outer cap for keeping liquid sealing with the upper lattice plate and a water level monitoring pipe extended to lower than the inner cap passing through the liquid sealing of the outer cap for sucking the atmosphere in the outer cap. Pressurized air is sent through the air supply pipe, to lower the water level of the coolants in the outer cap and the water level monitoring pipe sucks the pressurized air, by which the inside and the outside of the channel box are partitioned. Subsequently, if the sample water is sampled by a sampling tube, sampling water which enables accurate evaluation for radioactivity concentration in the fuel assembly can be obtained. (I.S.)

  7. European community light water reactor safety research projects. Experimental issue

    International Nuclear Information System (INIS)

    1975-01-01

    Research programs on light water reactor safety currently carried out in the European Community are presented. They cover: accident conditions (LOCA, ECCS, core meltdown, external influences, etc...), fault and accident prevention and means of mitigation, normal operation conditions, on and off site implications and equipment under severe accident conditions, and miscellaneous subjects

  8. Spectrophotometric Determination of Boron in Environmental Water Samples

    International Nuclear Information System (INIS)

    San San; Khin Win Kyi; Kwaw Naing

    2002-02-01

    The present paper deals with the study on the methods for the determination of boron in the environmental water samples. The standard methods which are useful for this determination are discussed thoroughly in this work. Among the standard methods approved by American Public Health Association, the carmine method was selected for this study. Prior to the determination of boron in the water samples, the precision and accuracy of the methods of choice were examined by using standard boron solutions. The determination of Boron was carried out by using water samples, waste water from Aquaculture Research Centre, University of Yangon, the Ayeyarwady River water near Magway Myathalon Pagoda in Magway Division, ground water from Sanchaung Township, and tap water from Universities' Research Centre, University of Yangon. Analyses of these water samples were done and statistical treatment of the results was carried out. (author)

  9. Extensive cultivation of soil and water samples yields various pathogens in patients with cystic fibrosis but not Burkholderia multivorans.

    Science.gov (United States)

    Peeters, Charlotte; Depoorter, Eliza; Praet, Jessy; Vandamme, Peter

    2016-11-01

    While the epidemiology of Burkholderia cepacia complex (Bcc) bacteria in cystic fibrosis (CF) patients suggests that Burkholderia multivorans is acquired from environmental sources, this species has rarely been isolated from soil and water samples. Multiple isolation strategies were applied to water and soil samples that were previously shown to be B. multivorans PCR positive. These included direct plating and liquid enrichment procedures and the use of selective media, acclimatizing recovery and co-cultivation with CF sputum. MALDI-TOF mass spectrometry and sequence analysis of 16S rRNA and housekeeping genes were used to identify all isolates. None of the approaches yielded B. multivorans isolates. Other Burkholderia species, several Gram-negative non-fermenting bacteria (including Cupriavidus, Inquilinus, Pandoraea, Pseudomonas and Stenotrophomonas) and rapidly growing mycobacteria (including Mycobacterium chelonae) were all isolated from water and soil samples. The use of Bcc isolation media yielded a surprisingly wide array of rare but often clinically relevant CF pathogens, confirming that soil and water are reservoirs of these infectious agents. Copyright © 2016 European Cystic Fibrosis Society. Published by Elsevier B.V. All rights reserved.

  10. UMTRA project water sampling and analysis plan, Maybell, Colorado

    International Nuclear Information System (INIS)

    1994-06-01

    This water sampling and analysis plan (WSAP) describes planned water sampling activities and provides the regulatory and technical basis for ground water sampling in 1994 at the US Department of Energy's (DOE) Uranium Mill Tailings Remedial Action (UMTRA) Project site in Maybell, Colorado. The WSAP identifies and justifies sampling locations, analytical parameters, and sampling frequencies at the site. The ground water data will be used for site characterization and risk assessment. The regulatory basis for the ground water and surface water monitoring activities is derived from the EPA regulations in 40 CFR Part 192 (1993) and the proposed EPA standards of 1987 (52 FR 36000). Sampling procedures are guided by the UMTRA Project standard operating procedures (SOP) (JEG, n.d.), the Technical Approach Document (TAD) (DOE, 1989), and the most effective technical approach for the site. This WSAP also includes a summary and the results of water sampling activities from 1989 through 1992 (no sampling was performed in 1993)

  11. Sampling art for ground-water monitoring wells in nuclide migration

    International Nuclear Information System (INIS)

    Liu Wenyuan; Tu Guorong; Dang Haijun; Wang Xuhui; Ke Changfeng

    2010-01-01

    Ground-Water sampling is one of the key parts in field nuclide migration. The objective of ground-water sampling program is to obtain samples that are representative of formation-quality water. In this paper, the ground-water sampling standards and the developments of sampling devices are reviewed. We also designed the sampling study projects which include the sampling methods, sampling parameters and the elementary devise of two types of ground-Water sampling devices. (authors)

  12. Natural Radioactivity Pattern of Surabaya Water Environmental Samples

    International Nuclear Information System (INIS)

    Rosidi; Agus Taftazani

    2007-01-01

    The gross β radioactivity and natural radionuclide of Surabaya environmental samples pattern have been evaluated. The environmental samples were chosen randomly at 12 locations. The environment samples were water (fresh, estuary and coastal), sediment, eichhornia crassipes (Mart) Solms, Mangrove (Rhizophora stylosa), (Moolgarda delicatus) fish and (Johnius (Johnieops) borneensis) (Sharpnose hammer croaker) fish. The water sample was evaporated; the sediment sample was dried and ground; the biotic samples was burnt at the temperature 500 °C ; The gross β measurement using GM detector and the radionuclides has been identified by γ spectrometer. From the investigation results could be concluded that the natural radioactivity of environmental samples was very low. gross-β of water samples were lower than the threshold value of local government regulation of Surabaya no: 2 year 2004 (1 Bq/L). The distribution of gross-β activity of eichhornia crassipes (Mart) Solms was higher than the other biotic, water and sediment samples as well as the accumulation of radionuclides in the water organism was taken place. The result of identification using γ spectrometer has detected 7 of radionuclides, i.e 210 Pb, 212 Pb, 214 Pb, 208 Tl, 214 Bi, 228 Ac, and 40 K in all sample. The distribution factor of sediment F D was less than bioaccumulation factor of biotic F B and it indicates that there the radionuclide accumulation migration follows the pattern of water - sediment - biotic sample. (author)

  13. UMTRA project water sampling and analysis plan, Naturita, Colorado

    International Nuclear Information System (INIS)

    1994-04-01

    Surface remedial action is scheduled to begin at the Naturita UMTRA Project processing site in the spring of 1994. No water sampling was performed during 1993 at either the Naturita processing site (NAT-01) or the Dry Flats disposal site (NAT-12). Results of previous water sampling at the Naturita processing site indicate that ground water in the alluvium is contaminated as a result of uranium processing activities. Baseline ground water conditions have been established in the uppermost aquifer at the Dry Flats disposal site. Water sampling activities scheduled for April 1994 include preconstruction sampling of selected monitor wells at the processing site, surface water sampling of the San Miguel River, sampling of several springs/seeps in the vicinity of the disposal site, and sampling of two monitor wells in Coke Oven Valley. The monitor well locations provide sampling points to characterize ground water quality and flow conditions in the vicinity of the sites. The list of analytes has been updated to reflect constituents related to uranium processing activities and the parameters needed for geochemical evaluation. Water sampling will be conducted annually at minimum during the period of construction activities

  14. Catch me if you can: Comparing ballast water sampling skids to traditional net sampling

    Science.gov (United States)

    Bradie, Johanna; Gianoli, Claudio; Linley, Robert Dallas; Schillak, Lothar; Schneider, Gerd; Stehouwer, Peter; Bailey, Sarah

    2018-03-01

    With the recent ratification of the International Convention for the Control and Management of Ships' Ballast Water and Sediments, 2004, it will soon be necessary to assess ships for compliance with ballast water discharge standards. Sampling skids that allow the efficient collection of ballast water samples in a compact space have been developed for this purpose. We ran 22 trials on board the RV Meteor from June 4-15, 2015 to evaluate the performance of three ballast water sampling devices (traditional plankton net, Triton sampling skid, SGS sampling skid) for three organism size classes: ≥ 50 μm, ≥ 10 μm to Natural sea water was run through the ballast water system and untreated samples were collected using paired sampling devices. Collected samples were analyzed in parallel by multiple analysts using several different analytic methods to quantify organism concentrations. To determine whether there were differences in the number of viable organisms collected across sampling devices, results were standardized and statistically treated to filter out other sources of variability, resulting in an outcome variable representing the mean difference in measurements that can be attributed to sampling devices. These results were tested for significance using pairwise Tukey contrasts. Differences in organism concentrations were found in 50% of comparisons between sampling skids and the plankton net for ≥ 50 μm, and ≥ 10 μm to < 50 μm size classes, with net samples containing either higher or lower densities. There were no differences for < 10 μm organisms. Future work will be required to explicitly examine the potential effects of flow velocity, sampling duration, sampled volume, and organism concentrations on sampling device performance.

  15. Advances in Radiocarbon Measurement of Water Samples

    Energy Technology Data Exchange (ETDEWEB)

    Janovics, R.; Molnar, M.; Major, I. [Institute of Nuclear Research (ATO MKI), Hungarian Academy of Sciences, H-4001 Debrecen (Hungary); Svetlik, I. [Department of Radiation Dosimetry, Nuclear Physics Institute AS CR, Prague (Czech Republic); Wacker, L. [Institute for Particle Physics, ETH Hoenggerberg, Zuerich (Switzerland)

    2013-07-15

    In this paper two very different and novel methods for the {sup 14}C measurement of water samples are presented. The first method uses direct absorption into a scintillation cocktail and a following liquid scintillation measurement. Typical sample size is 20-40 L and overall uncertainty is {+-} 2% for modern samples. It is a very cost effective and easy to use method based on a novel and simple static absorption process for the CO{sub 2} extracted from groundwater. The other very sensitive method is based on accelerator mass spectrometry (AMS) using a gas ion source. With a MICADAS type AMS system we demonstrated that you can routinely measure the {sup 14}C content of 1 mL of water sample with better than 1% precision (for a modern sample). This direct {sup 14}C AMS measurement of water takes less than 20 minutes including sample preparation. (author)

  16. UMTRA project water sampling and analysis plan, Gunnison, Colorado

    International Nuclear Information System (INIS)

    1994-06-01

    This water sampling and analysis plan summarizes the results of previous water sampling activities and the plan for water sampling activities for calendar year 1994. A buffer zone monitoring plan is included as an appendix. The buffer zone monitoring plan is designed to protect the public from residual contamination that entered the ground water as a result of former milling operations. Surface remedial action at the Gunnison Uranium Mill Tailings Remedial Action Project site began in 1992; completion is expected in 1995. Ground water and surface water will be sampled semiannually in 1994 at the Gunnison processing site (GUN-01) and disposal site (GUN-08). Results of previous water sampling at the Gunnison processing site indicate that ground water in the alluvium is contaminated by the former uranium processing activities. Background ground water conditions have been established in the uppermost aquifer (Tertiary gravels) at the Gunnison disposal site. The monitor well locations provide a representative distribution of sampling points to characterize ground water quality and ground water flow conditions in the vicinity of the sites. The list of analytes has been modified with time to reflect constituents that are related to uranium processing activities and the parameters needed for geochemical evaluation. Water sampling will be conducted at least semiannually during and one year following the period of construction activities, to comply with the ground water protection strategy discussed in the remedial action plan (DOE, 1992a)

  17. Gas-driven pump for ground-water samples

    Science.gov (United States)

    Signor, Donald C.

    1978-01-01

    Observation wells installed for artificial-recharge research and other wells used in different ground-water programs are frequently cased with small-diameter steel pipe. To obtain samples from these small-diameter wells in order to monitor water quality, and to calibrate solute-transport models, a small-diameter pump with unique operating characteristics is required that causes a minimum alternation of samples during field sampling. A small-diameter gas-driven pump was designed and built to obtain water samples from wells of two-inch diameter or larger. The pump is a double-piston type with the following characteristics: (1) The water sample is isolated from the operating gas, (2) no source of electricity is ncessary, (3) operation is continuous, (4) use of compressed gas is efficient, and (5) operation is reliable over extended periods of time. Principles of operation, actual operation techniques, gas-use analyses and operating experience are described. Complete working drawings and a component list are included. Recent modifications and pump construction for high-pressure applications also are described. (Woodard-USGS)

  18. European Climate Change Programme. Working Group II. Impacts and Adaptation. Water Management. Sectoral Report

    International Nuclear Information System (INIS)

    2007-03-01

    Adaptation is a new policy area for the European climate change policy. The Impacts and Adaptation Workgroup has been set up as part of European Climate Change Programme (ECCP II). The main objective of the workgroup is to explore options to improve Europe's resilience to Climate Change Impacts, to encourage the integration of climate change adaptation into other policy areas at the European, national and regional level and to define the role of EU-wide policies complementing action by Member States. The aim of this initial programme of work is to identify good practice in the development of adaptation policy and foster learning from different sectoral experiences and explore a possible EU role in adaptation policies. The Commission has led a series of 10 sectoral meetings looking at adaptation issues for different sectors. One of these meetings looked at the impacts on the water cycle and water resources management and prediction of extreme events in particular. This report summarises the state of play in the Water Resources sector in relation to adaptation to climate change on the basis of the information gathered at the stakeholder meeting on 11 April, 2006

  19. Implementation options for DNA-based identification into ecological status assessment under the European Water Framework Directive.

    Science.gov (United States)

    Hering, Daniel; Borja, Angel; Jones, J Iwan; Pont, Didier; Boets, Pieter; Bouchez, Agnes; Bruce, Kat; Drakare, Stina; Hänfling, Bernd; Kahlert, Maria; Leese, Florian; Meissner, Kristian; Mergen, Patricia; Reyjol, Yorick; Segurado, Pedro; Vogler, Alfried; Kelly, Martyn

    2018-07-01

    Assessment of ecological status for the European Water Framework Directive (WFD) is based on "Biological Quality Elements" (BQEs), namely phytoplankton, benthic flora, benthic invertebrates and fish. Morphological identification of these organisms is a time-consuming and expensive procedure. Here, we assess the options for complementing and, perhaps, replacing morphological identification with procedures using eDNA, metabarcoding or similar approaches. We rate the applicability of DNA-based identification for the individual BQEs and water categories (rivers, lakes, transitional and coastal waters) against eleven criteria, summarised under the headlines representativeness (for example suitability of current sampling methods for DNA-based identification, errors from DNA-based species detection), sensitivity (for example capability to detect sensitive taxa, unassigned reads), precision of DNA-based identification (knowledge about uncertainty), comparability with conventional approaches (for example sensitivity of metrics to differences in DNA-based identification), cost effectiveness and environmental impact. Overall, suitability of DNA-based identification is particularly high for fish, as eDNA is a well-suited sampling approach which can replace expensive and potentially harmful methods such as gill-netting, trawling or electrofishing. Furthermore, there are attempts to replace absolute by relative abundance in metric calculations. For invertebrates and phytobenthos, the main challenges include the modification of indices and completing barcode libraries. For phytoplankton, the barcode libraries are even more problematic, due to the high taxonomic diversity in plankton samples. If current assessment concepts are kept, DNA-based identification is least appropriate for macrophytes (rivers, lakes) and angiosperms/macroalgae (transitional and coastal waters), which are surveyed rather than sampled. We discuss general implications of implementing DNA-based identification

  20. Untangling the effects of multiple human stressors and their impacts on fish assemblages in European running waters.

    Science.gov (United States)

    Schinegger, Rafaela; Palt, Martin; Segurado, Pedro; Schmutz, Stefan

    2016-12-15

    This work addresses human stressors and their impacts on fish assemblages at pan-European scale by analysing single and multiple stressors and their interactions. Based on an extensive dataset with 3105 fish sampling sites, patterns of stressors, their combination and nature of interactions, i.e. synergistic, antagonistic and additive were investigated. Geographical distribution and patterns of seven human stressor variables, belonging to four stressor groups (hydrological-, morphological-, water quality- and connectivity stressors), were examined, considering both single and multiple stressor combinations. To quantify the stressors' ecological impact, a set of 22 fish metrics for various fish assemblage types (headwaters, medium gradient rivers, lowland rivers and Mediterranean streams) was analysed by comparing their observed and expected response to different stressors, both acting individually and in combination. Overall, investigated fish sampling sites are affected by 15 different stressor combinations, including 4 stressors acting individually and 11 combinations of two or more stressors; up to 4 stressor groups per fish sampling site occur. Stressor-response analysis shows divergent results among different stressor categories, even though a general trend of decreasing ecological integrity with increasing stressor quantity can be observed. Fish metrics based on density of species 'intolerant to water quality degradation' and 'intolerant to oxygen depletion" responded best to single and multiple stressors and their interactions. Interactions of stressors were additive (40%), synergistic (30%) or antagonistic (30%), emphasizing the importance to consider interactions in multi-stressor analyses. While antagonistic effects are only observed in headwaters and medium-gradient rivers, synergistic effects increase from headwaters over medium gradient rivers and Mediterranean streams to large lowland rivers. The knowledge gained in this work provides a basis for

  1. Radon in water samples around Ningyo Toge area

    Energy Technology Data Exchange (ETDEWEB)

    Furuta, Sadaaki [Power Reactor and Nuclear Fuel Development Corp., Kamisaibara, Okayama (Japan). Ningyo Toge Works

    1997-02-01

    Radon concentrations of river water and drinking water were surveyed. Water samples were collected from the region around Ningyo-Toge Works which were positioned on a granitic layer having uranium deposit. Each sample was taken using a separating funnel and the radioactivity was counted by liquid scintillation counter (ALOKA, LB-2). Since there were old working places of mine in the region, mine drainages from them were also analyzed. The radon concentration of drinking water from the region ranged from 0.1 to 230 Bq/l. The samples with a higher activity than 100 Bq/l were water from springs or wells and the area of the highest Rn concentration was on a typical granitic layer, suggesting some geographic effects on Rn concentration. Some samples of drinking water had slightly higher levels of Rn, probably due to the utilization of underflow as its source. The mean concentration of Rn became higher in the order; river water, drinking water, mine drainage in the region. In addition, a negative correlation between Rn concentration of water and the river flow rate was observed in this region. (M.N.)

  2. Water sample-collection and distribution system

    Science.gov (United States)

    Brooks, R. R.

    1978-01-01

    Collection and distribution system samples water from six designated stations, filtered if desired, and delivers it to various analytical sensors. System may be controlled by Water Monitoring Data Acquisition System or operated manually.

  3. Quality-control design for surface-water sampling in the National Water-Quality Network

    Science.gov (United States)

    Riskin, Melissa L.; Reutter, David C.; Martin, Jeffrey D.; Mueller, David K.

    2018-04-10

    The data-quality objectives for samples collected at surface-water sites in the National Water-Quality Network include estimating the extent to which contamination, matrix effects, and measurement variability affect interpretation of environmental conditions. Quality-control samples provide insight into how well the samples collected at surface-water sites represent the true environmental conditions. Quality-control samples used in this program include field blanks, replicates, and field matrix spikes. This report describes the design for collection of these quality-control samples and the data management needed to properly identify these samples in the U.S. Geological Survey’s national database.

  4. The WIPP Water Quality Sampling Program

    International Nuclear Information System (INIS)

    Uhland, D.; Morse, J.G.; Colton, D.

    1986-01-01

    The Waste Isolation Pilot Plant (WIPP), a Department of Energy facility, will be used for the underground disposal of wastes. The Water Quality Sampling Program (WQSP) is designed to obtain representative and reproducible water samples to depict accurate water composition data for characterization and monitoring programs in the vicinity of the WIPP. The WQSP is designed to input data into four major programs for the WIPP project: Geochemical Site Characterization, Radiological Baseline, Environmental Baseline, and Performance Assessment. The water-bearing units of interest are the Culebra and Magneta Dolomite Members of the Rustler Formation, units in the Dewey Lake Redbeds, and the Bell Canyon Formation. At least two chemically distinct types of water occur in the Culebra, one being a sodium/potassium chloride water and the other being a calcium/magnesium sulfate water. Water from the Culebra wells to the south of the WIPP site is distinctly fresher and tends to be of the calcium/magnesium sulfate type. Water in the Culebra in the north and around the WIPP site is distinctly fresher and tends to be of the sodium/potassium chloride type and is much higher in total dissolved solids. The program, which is currently 1 year old, will continue throughout the life of the facility as part of the Environmental Monitoring Program

  5. Validation of single-sample doubly labeled water method

    International Nuclear Information System (INIS)

    Webster, M.D.; Weathers, W.W.

    1989-01-01

    We have experimentally validated a single-sample variant of the doubly labeled water method for measuring metabolic rate and water turnover in a very small passerine bird, the verdin (Auriparus flaviceps). We measured CO 2 production using the Haldane gravimetric technique and compared these values with estimates derived from isotopic data. Doubly labeled water results based on the one-sample calculations differed from Haldane values by less than 0.5% on average (range -8.3 to 11.2%, n = 9). Water flux computed by the single-sample method differed by -1.5% on average from results for the same birds based on the standard, two-sample technique (range -13.7 to 2.0%, n = 9)

  6. Design description of the European pressurized water reactor

    International Nuclear Information System (INIS)

    Leverenz, R.

    1999-01-01

    The EPR (the European Pressurized Water Reactor) is an evolutionary PWR developed by Nuclear Power International and its parent companies, Framatome and Siemens, in co-operation with Electricite de France and German Utilities. NPI can rely on the huge experience gained by its parent companies; they have constructed more than 100 nuclear power plants throughout the world. The total installed capacity exceeds 100,000 MW - about 25% of the total world-wide figure. Following the conceptual design phase of the so-called Common Product conducted by NPI, Framatome and Siemens, from 1989 through 1991, Electricite de France (EDF) and several major German utilities decided to merge their own development programmes, - the N4 Plus and REP 2000 projects on the French side and the further development of the KONVOI technology on the German side, - with the NPI project. From that time on, the NPI project became one single common development line for both countries. In parallel, EDF and the German utilities decided to establish, together with other European utilities, specifications that would represent common utility views on the design and performance of future nuclear power plants. These are documented in the European Utility Requirements (EURs). The basic design has been completed in 1997, and in 1998 a design optimization is being carried out with the goal to even increase the economic competitiveness of nuclear power. This paper provides a brief design description of the EPR. (author)

  7. EURO-CARES: European Roadmap for a Sample Return Curation Facility and Planetary Protection Implications.

    Science.gov (United States)

    Brucato, John Robert

    2016-07-01

    A mature European planetary exploration program and evolving sample return mission plans gathers the interest of a wider scientific community. The interest is generated from studying extraterrestrial samples in the laborato-ry providing new opportunities to address fundamental issues on the origin and evolution of the Solar System, on the primordial cosmochemistry, and on the nature of the building blocks of terrestrial planets and on the origin of life. Major space agencies are currently planning for missions that will collect samples from a variety of Solar Sys-tem environments, from primitive (carbonaceous) small bodies, from the Moon, Mars and its moons and, final-ly, from icy moons of the outer planets. A dedicated sample return curation facility is seen as an essential re-quirement for the receiving, assessment, characterization and secure preservation of the collected extraterrestrial samples and potentially their safe distribution to the scientific community. EURO-CARES is a European Commission study funded under the Horizon-2020 program. The strategic objec-tive of EURO-CARES is to create a roadmap for the implementation of a European Extraterrestrial Sample Cu-ration Facility. The facility has to provide safe storage and handling of extraterrestrial samples and has to enable the preliminary characterization in order to achieve the required effectiveness and collaborative outcomes for the whole international scientific community. For example, samples returned from Mars could pose a threat on the Earth's biosphere if any living extraterrestrial organism are present in the samples. Thus planetary protection is an essential aspect of all Mars sample return missions that will affect the retrival and transport from the point of return, sample handling, infrastructure methodology and management of a future curation facility. Analysis of the state of the art of Planetary Protection technology shows there are considerable possibilities to define and develop

  8. Income, Economic Structure and Trade: Impacts on Recent Water Use Trends in the European Union

    Directory of Open Access Journals (Sweden)

    Rosa Duarte

    2018-01-01

    Full Text Available From the mid-1990s to the recent international economic crisis, the European Union (EU27 experienced a significant economic growth and a flat population increase. During these years, the water resources directly used by the EU countries displayed a growing but smooth trend. However, European activities intensively demanded water resources throughout the whole global supply chain. The growth rate of embodied water use was three times higher than the growth in water directly used by these economies. This was mainly due to the large upsurge of virtual water imports in the EU (e.g., about 25% of the change in water imports in the world was directly linked to the increasing imports in the EU27 countries. In this context, we analyze water use changes in the EU27 from 1995 to 2009, combining the production and consumption perspectives. To that aim, we use the environmentally extended input-output approach to obtain the volume of water embodied in domestic production and in trade flows at the sector and country levels. In the empirical analysis, we utilize multi-regional input-output data from the World Input Output Database. In addition, by means of a structural decomposition analysis we identify and quantify the factors explaining changes in these trends. We focus both on the role of domestic production and trade and estimate the associated intensity, technology and scale effects. This analysis is done for different clusters, identifying singular patterns depending on income criteria. Our results confirm the boost of demand growth in that period, the positive but negligible effect of structural change, and the decline in water intensity which, however, was not enough to compensate the effects on water associated to the economic expansion in the period. These findings also point at a gradual substitution of domestic water use for virtual water imports. More concretely, in most countries the food industry tended to reduce its backward linkages with the

  9. Biogeography of Wood-Boring Crustaceans (Isopoda: Limnoriidae) Established in European Coastal Waters

    Science.gov (United States)

    Borges, Luísa M. S.; Merckelbach, Lucas M.; Cragg, Simon M.

    2014-01-01

    Marine wood-borers of the Limnoriidae cause great destruction to wooden structures exposed in the marine environment. In this study we collated occurrence data obtained from field surveys, spanning over a period of 10 years, and from an extensive literature review. We aimed to determine which wood-boring limnoriid species are established in European coastal waters; to map their past and recent distribution in Europe in order to infer species range extension or contraction; to determine species environmental requirements using climatic envelopes. Of the six species of wood-boring Limnoria previously reported occurring in Europe, only Limnoria lignorum, L. quadripunctata and L. tripunctata are established in European coastal waters. L. carinata and L. tuberculata have uncertain established status, whereas L. borealis is not established in European waters. The species with the widest distribution in Europe is Limnoria lignorum, which is also the most tolerant species to a range of salinities. L. quadripunctata and L. tripunctata appear to be stenohaline. However, the present study shows that both L. quadripunctata and L. tripunctata are more widespread in Europe than previous reports suggested. Both species have been found occurring in Europe since they were described, and their increased distribution is probably the results of a range expansion. On the other hand L. lignorum appears to be retreating poleward with ocean warming. In certain areas (e.g. southern England, and southern Portugal), limnoriids appear to be very abundant and their activity is rivalling that of teredinids. Therefore, it is important to monitor the distribution and destructive activity of these organisms in Europe. PMID:25313796

  10. The development of water services and their interaction with water resources in European and Brazilian cities

    Science.gov (United States)

    Barraqué, B.; Formiga Johnsson, R. M.; Nogueira de Paiva Britto, A. L.

    2008-08-01

    The extension and complexity of large cities creates "urban water" and a related issue: public water services, including public water supply, sewage collection and treatment, and storm water control, had previously become a policy sector separate from water resource allocation issues thanks to water transport and treatment technologies. Large metropolitan areas today cannot take nature for granted anymore, and they need to protect water resources, if only to reduce the long term cost of transporting and treating water. In this paper, we compare the historical development of water services in European and Brazilian metropolitan areas, placing the technological developments in their geographic, socio-economic and political contexts. Our frame is to follow the successive contributions of civil engineering, sanitary engineering, and environmental engineering: the "quantity of water" and civil engineering paradigm allowed to mobilise water in and out of the city, and up the hills or the floors; in the "water quality" and chemical/sanitary engineering paradigm, water treatment gave more freedom to cities to take water from rivers closer to them, but also to reduce sewer discharge impacts; lastly, the environmental engineering paradigm proposes to overcome the supply side perspective, by introducing demand side management, water conservation, water allocation flexibilisation, and an integrated approach to water services, water resources management, and land use policies.

  11. Environmental health research in the UK and European Union : research priorities in water and air pollution control

    Energy Technology Data Exchange (ETDEWEB)

    Ince, M; Wheatley, A [Loughborough Univ. of Technology (United Kingdom). Dept. of Civil Engineering

    1997-12-31

    The contents are involvement of the European community, integration of research and development programmes ; surface water quality and pollution incidents; surface water pollution in the UK ; eutrophication ; drinking water quality ; causes and current treatment for removal of pollutants ; future causes of water pollution ; and , water and wastewater research.

  12. Environmental health research in the UK and European Union : research priorities in water and air pollution control

    International Nuclear Information System (INIS)

    Ince, M.; Wheatley, A.

    1996-01-01

    The contents are involvement of the European community, integration of research and development programmes ; surface water quality and pollution incidents; surface water pollution in the UK ; eutrophication ; drinking water quality ; causes and current treatment for removal of pollutants ; future causes of water pollution ; and , water and wastewater research

  13. Drinking Water Disinfection By-products, Genetic Polymorphisms, and Birth Outcomes in a European Mother-Child Cohort Study.

    Science.gov (United States)

    Kogevinas, Manolis; Bustamante, Mariona; Gracia-Lavedán, Esther; Ballester, Ferran; Cordier, Sylvaine; Costet, Nathalie; Espinosa, Ana; Grazuleviciene, Regina; Danileviciute, Asta; Ibarluzea, Jesus; Karadanelli, Maria; Krasner, Stuart; Patelarou, Evridiki; Stephanou, Euripides; Tardón, Adonina; Toledano, Mireille B; Wright, John; Villanueva, Cristina M; Nieuwenhuijsen, Mark

    2016-11-01

    We examined the association between exposure during pregnancy to trihalomethanes, the most common water disinfection by-products, and birth outcomes in a European cohort study (Health Impacts of Long-Term Exposure to Disinfection By-Products in Drinking Water). We took into account exposure through different water uses, measures of water toxicity, and genetic susceptibility. We enrolled 14,005 mothers (2002-2010) and their children from France, Greece, Lithuania, Spain, and the UK. Information on lifestyle- and water-related activities was recorded. We ascertained residential concentrations of trihalomethanes through regulatory records and ad hoc sampling campaigns and estimated route-specific trihalomethane uptake by trimester and for whole pregnancy. We examined single nucleotide polymorphisms and copy number variants in disinfection by-product metabolizing genes in nested case-control studies. Average levels of trihalomethanes ranged from around 10 μg/L to above the regulatory limits in the EU of 100 μg/L between centers. There was no association between birth weight and total trihalomethane exposure during pregnancy (β = 2.2 g in birth weight per 10 μg/L of trihalomethane, 95% confidence interval = 3.3, 7.6). Birth weight was not associated with exposure through different routes or with specific trihalomethane species. Exposure to trihalomethanes was not associated with low birth weight (odds ratio [OR] per 10 μg/L = 1.02, 95% confidence interval = 0.95, 1.10), small-for-gestational age (OR = 0.99, 0.94, 1.03) and preterm births (OR = 0.98, 0.9, 1.05). We found no gene-environment interactions for mother or child polymorphisms in relation to preterm birth or small-for-gestational age. In this large European study, we found no association between birth outcomes and trihalomethane exposures during pregnancy in the total population or in potentially genetically susceptible subgroups. (See video abstract at http://links.lww.com/EDE/B104.).

  14. Soil Gas Sample Handling: Evaluation of Water Removal and Sample Ganging

    Energy Technology Data Exchange (ETDEWEB)

    Fritz, Brad G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Abrecht, David G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Hayes, James C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Mendoza, Donaldo P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-10-31

    Soil gas sampling is currently conducted in support of Nuclear Test Ban treaty verification. Soil gas samples are collected and analyzed for isotopes of interest. Some issues that can impact sampling and analysis of these samples are excess moisture and sample processing time. Here we discuss three potential improvements to the current sampling protocol; a desiccant for water removal, use of molecular sieve to remove CO2 from the sample during collection, and a ganging manifold to allow composite analysis of multiple samples.

  15. Ground-water sample collection and analysis plan for the ground-water surveillance project

    International Nuclear Information System (INIS)

    Bryce, R.W.; Evans, J.C.; Olsen, K.B.

    1991-12-01

    The Pacific Northwest Laboratory performs ground-water sampling activities at the US Department of Energy's (DOE's) Hanford Site in support of DOE's environmental surveillance responsibilities. The purpose of this document is to translate DOE's General Environmental Protection Program (DOE Order 5400.1) into a comprehensive ground-water sample collection and analysis plan for the Hanford Site. This sample collection and analysis plan sets forth the environmental surveillance objectives applicable to ground water, identifies the strategy for selecting sample collection locations, and lists the analyses to be performed to meet those objectives

  16. Description of European Space Agency (ESA) Concept Development for a Mars Sample Receiving Facility (MSRF)

    Science.gov (United States)

    Vrublevskis, J.; Berthoud, L.; Guest, M.; Smith, C.; Bennett, A.; Gaubert, F.; Schroeven-Deceuninck, H.; Duvet, L.; van Winnendael, M.

    2018-04-01

    This presentation gives an overview of the several studies conducted for the European Space Agency (ESA) since 2007, which progressively developed layouts for a potential implementation of a Mars Sample Receiving Facility (MSRF).

  17. Evaluation of damages of airplane crash in European Advanced Boiling Water Reactor (EU-ABWR)

    International Nuclear Information System (INIS)

    Kamei, Kazuhiro; Tanoue, Tetsuharu; Kataoka, Kazuyoshi; Jimbo, Masakazu

    2011-01-01

    European Advanced Boiling Water Reactor (EU-ABWR) is developed by Toshiba. EU-ABWR accommodates an armored reactor building against Airplane Crash (APC), severe accident mitigation systems, N+2 principle in safety systems and a large output of 1600 MWe. Thanks to above mentioned features, EU-ABWR's design objectives and principles are consistent with safety requirements in an European market. In this paper, evaluation of damages induced by APC has been summarized. (author)

  18. PCR detection of Burkholderia multivorans in water and soil samples.

    Science.gov (United States)

    Peeters, Charlotte; Daenekindt, Stijn; Vandamme, Peter

    2016-08-12

    Although semi-selective growth media have been developed for the isolation of Burkholderia cepacia complex bacteria from the environment, thus far Burkholderia multivorans has rarely been isolated from such samples. Because environmental B. multivorans isolates mainly originate from water samples, we hypothesized that water rather than soil is its most likely environmental niche. The aim of the present study was to assess the occurrence of B. multivorans in water samples from Flanders (Belgium) using a fast, culture-independent PCR assay. A nested PCR approach was used to achieve high sensitivity, and specificity was confirmed by sequencing the resulting amplicons. B. multivorans was detected in 11 % of the water samples (n = 112) and 92 % of the soil samples (n = 25) tested. The percentage of false positives was higher for water samples compared to soil samples, showing that the presently available B. multivorans recA primers lack specificity when applied to the analysis of water samples. The results of the present study demonstrate that B. multivorans DNA is commonly present in soil samples and to a lesser extent in water samples in Flanders (Belgium).

  19. The future of Managed Aquifer Recharge in Italy: the European FPVII MARSOL Project and the European Innovation Partnership on Water Mar to Market

    Directory of Open Access Journals (Sweden)

    Rudy Rossetto

    2014-09-01

    Full Text Available Water scarcity, especially in the Mediterranean rim, poses the relevant issue of water saving in human activities and of finding new sources of water, also for agro-ecosystem maintenance. Managed Aquifer Recharge (MAR techniques constitute a promising solution to the above-mentioned issue. In this contribution, we discuss the state of MAR application in Italy also in relation to some projects co-funded by the European Union. Some ideas for the large scale application of these techniques for non-conventional water use are presented.

  20. Sampling procedure, receipt and conservation of water samples to determine environmental radioactivity

    International Nuclear Information System (INIS)

    Herranz, M.; Navarro, E.; Payeras, J.

    2009-01-01

    The present document informs about essential goals, processes and contents that the subgroups Sampling and Samples Preparation and Conservation believe they should be part of the procedure to obtain a correct sampling, receipt, conservation and preparation of samples of continental, marine and waste water before qualifying its radioactive content.

  1. The development of water services and their interaction with water resources in European and Brazilian cities

    Directory of Open Access Journals (Sweden)

    B. Barraqué

    2008-08-01

    Full Text Available The extension and complexity of large cities creates "urban water" and a related issue: public water services, including public water supply, sewage collection and treatment, and storm water control, had previously become a policy sector separate from water resource allocation issues thanks to water transport and treatment technologies. Large metropolitan areas today cannot take nature for granted anymore, and they need to protect water resources, if only to reduce the long term cost of transporting and treating water. In this paper, we compare the historical development of water services in European and Brazilian metropolitan areas, placing the technological developments in their geographic, socio-economic and political contexts. Our frame is to follow the successive contributions of civil engineering, sanitary engineering, and environmental engineering: the "quantity of water" and civil engineering paradigm allowed to mobilise water in and out of the city, and up the hills or the floors; in the "water quality" and chemical/sanitary engineering paradigm, water treatment gave more freedom to cities to take water from rivers closer to them, but also to reduce sewer discharge impacts; lastly, the environmental engineering paradigm proposes to overcome the supply side perspective, by introducing demand side management, water conservation, water allocation flexibilisation, and an integrated approach to water services, water resources management, and land use policies.

  2. UMTRA water sampling and analysis plan, Green River, Utah

    International Nuclear Information System (INIS)

    Papusch, R.

    1993-12-01

    The purpose of this water sampling and analysis plan (WSAP) is to provide a basis for groundwater and surface water sampling at the Green River Uranium Mill Tailing Remedial Action (UMTRA) Project site. This WSAP identifies and justifies the sampling locations, analytical parameters, detection limits, and sampling frequency for the monitoring locations

  3. Results of environmental radioactivity measurements in the Member States of the European Community for air - deposition - water - milk - 1977

    International Nuclear Information System (INIS)

    1979-01-01

    The present document is the seventeenth report published by the Health and Safety Directorate of the Commission of the European Communities concerning ambient radioactivity. It was drawn up using the data collected by the stations responsible for environmental radioactivity monitoring in the Member States. The results are extracts from the data sent to the Commission in application of Article 36 of the Treaty of Rome establishing the European Atomic Energy Community. The results presented in this report deal with radioactive contamination of the air, precipitation and fallout, surface water and milk during 1977 in the nine Member States of the European Community, viz. Belgium, Denmark, the Federal Republic of Germany, France, Italy, Ireland, Luxembourg, the Netherlands and the United Kingdom. The report also contains supplementary data on short-lived radioelements detected during the fourth quarter of 1977, the list of sampling stations and laboratories together With a list of publications by Member States in this field. This report places special emphasis on the measurement results for specific radionuclides, but it also contains data on total beta activity so as to ensure continuity vis-a-vis previous reports and provide comparative values

  4. Physico-chemical characteristics of water sample from Aiba Stream ...

    African Journals Online (AJOL)

    This study aimed at assessing the effectiveness of solar distillation in purification of water. The water sample collected from Aiba stream was subjected to double slope solar water distillation unit. The physico- chemical characteristics of the raw sample and the distillate were determined using standard methods. The.

  5. Measurement of 90Sr in fresh water samples

    International Nuclear Information System (INIS)

    Belanova, A.; Meresova, J.; Svetlik, I.; Tomaskova, L.

    2008-01-01

    This preliminary study show new experimental approach to the determination of the radionuclide 90 Sr in water samples. The new method of dynamic windows utilizing liquid scintillation counting was applied on model and surface water samples. Our results show the demand of separation technique with significantly higher yields. (authors)

  6. Diverse replication-associated protein encoding circular DNA viruses in guano samples of Central-Eastern European bats.

    Science.gov (United States)

    Kemenesi, Gábor; Kurucz, Kornélia; Zana, Brigitta; Földes, Fanni; Urbán, Péter; Vlaschenko, Anton; Kravchenko, Kseniia; Budinski, Ivana; Szodoray-Parádi, Farkas; Bücs, Szilárd; Jére, Csaba; Csősz, István; Szodoray-Parádi, Abigél; Estók, Péter; Görföl, Tamás; Boldogh, Sándor; Jakab, Ferenc

    2018-03-01

    Circular replication-associated protein encoding single-stranded DNA (CRESS DNA) viruses are increasingly recognized worldwide in a variety of samples. Representative members include well-described veterinary pathogens with worldwide distribution, such as porcine circoviruses or beak and feather disease virus. In addition, numerous novel viruses belonging to the family Circoviridae with unverified pathogenic roles have been discovered in different human samples. Viruses of the family Genomoviridae have also been described as being highly abundant in different faecal and environmental samples, with case reports showing them to be suspected pathogens in human infections. In order to investigate the genetic diversity of these viruses in European bat populations, we tested guano samples from Georgia, Hungary, Romania, Serbia and Ukraine. This resulted in the detection of six novel members of the family Circoviridae and two novel members of the family Genomoviridae. Interestingly, a gemini-like virus, namely niminivirus, which was originally found in raw sewage samples in Nigeria, was also detected in our samples. We analyzed the nucleotide composition of members of the family Circoviridae to determine the possible host origins of these viruses. This study provides the first dataset on CRESS DNA viruses of European bats, and members of several novel viral species were discovered.

  7. Water Property Models as Sovereignty Prerogatives: European Legal Perspectives in Comparison

    Directory of Open Access Journals (Sweden)

    Dario Casalini

    2010-08-01

    Full Text Available Water resources in European legal systems have always been vested in sovereign power, regardless of their legal nature as goods vested in State property or as res communes omnium not subject to ownership. The common legal foundation of sovereign power over water resources departed once civil law jurisdictions leveled the demesne on ownership model, by introducing public ownership in the French codification of 1804, while common law jurisdiction developed a broader legal concept of property that includes even the rights to use res communes. The models led respectively to the establishment of administrative systems of water rights and markets of water rights. According to the first, public authorities’ power to manage and preserve water resources is grounded in a derogatory regime, whereby water rights, grounded on licenses or concessions, are neither transferable nor tradeable. On the contrary, environmental and social concerns in water market schemes must be enforced by means of regulation, thus limiting private property rights on water, in compliance with the constitutional and common law constraints set out to protect the minimum content of property as a fundamental human right.

  8. Reduced European emissions of S and N - Effects on air concentrations, deposition and soil water chemistry in Swedish forests

    Energy Technology Data Exchange (ETDEWEB)

    Pihl Karlsson, Gunilla, E-mail: gunilla.pihl.karlsson@ivl.se [IVL Swedish Environmental Research Institute, Box 5302, SE-400 14 Gothenburg (Sweden); Akselsson, Cecilia, E-mail: cecilia.akselsson@nateko.lu.se [Department of Earth and Ecosystem Sciences, Lund University, Soelvegatan 12, SE-223 62 Lund (Sweden); Hellsten, Sofie, E-mail: sofie.hellsten@ivl.se [IVL Swedish Environmental Research Institute, Box 5302, SE-400 14 Gothenburg (Sweden); Karlsson, Per Erik, E-mail: pererik.karlsson@ivl.se [IVL Swedish Environmental Research Institute, Box 5302, SE-400 14 Gothenburg (Sweden)

    2011-12-15

    Changes in sulphur and nitrogen pollution in Swedish forests have been assessed in relation to European emission reductions, based on measurements in the Swedish Throughfall Monitoring Network. Measurements were analysed over 20 years with a focus on the 12-year period 1996 to 2008. Air concentrations of SO{sub 2} and NO{sub 2}, have decreased. The SO{sub 4}-deposition has decreased in parallel with the European emission reductions. Soil water SO{sub 4}-concentrations have decreased at most sites but the pH, ANC and inorganic Al-concentrations indicated acidification recovery only at some of the sites. No changes in the bulk deposition of inorganic nitrogen could be demonstrated. Elevated NO{sub 3}-concentrations in the soil water occurred at irregular occasions at some southern sites. Despite considerable air pollution emission reductions in Europe, acidification recovery in Swedish forests soils is slow. Nitrogen deposition to Swedish forests continues at elevated levels that may lead to leaching of nitrate to surface waters. - Highlights: > S deposition to Swedish forests has decreased in parallel with European emissions. > Soil water pH, ANC and inorganic Al-concentrations indicated a slow recovery. > The bulk deposition of inorganic nitrogen over Sweden has not decreased. > Continued N deposition to Swedish forests may cause leaching of N to surface waters. - Reduced European emissions have led to decreased acidic deposition and a slow recovery of soil water but nitrogen deposition remains the same in Swedish forests.

  9. The asian decapod Hemigrapsus penicillatus (de Haan, 1835) (Grapsidae, Decapoda) introduced in European waters: status quo and future perspective

    Science.gov (United States)

    Gollasch, S.

    1998-09-01

    The Asian decapod Hemigrapsus penicillatus (de Haan, 1835) was first recorded in European waters in 1994. The first specimens were collected in the estuary of Charente Maritime on the west coast of France close to La Rochelle. The current range in Europe covers Spanish shallow water habitats of the Bay of Biscay to areas north of La Rochelle (France). Densities of up to 20 specimens per square metre occur. This species has a high temperature and salinity tolerace and will expand its distribution in European waters. It is not clear whether this crab was introduced by shipping in ballast water or as a fouling organism. Based on a study of ship hull fouling in German dry docks this account provides evidence that hull fouling is a likely vector for the introduction of this crab. In August 1993, six juvenile specimens of H. penicillatus were removed from the hull of a car-carrier. After its journey from Japan into European waters this vessel docked in the port of Bremerhaven (Germany) for a routine inspection and coating with antifouling paint.

  10. Self-similar distribution of oil spills in European coastal waters

    International Nuclear Information System (INIS)

    Redondo, Jose M; Platonov, Alexei K

    2009-01-01

    Marine pollution has been highlighted thanks to the advances in detection techniques as well as increasing coverage of catastrophes (e.g. the oil tankers Amoco Cadiz, Exxon Valdez, Erika, and Prestige) and of smaller oil spills from ships. The new satellite based sensors SAR and ASAR and new methods of oil spill detection and analysis coupled with self-similar statistical techniques allow surveys of environmental pollution monitoring large areas of the ocean. We present a statistical analysis of more than 700 SAR images obtained during 1996-2000, also comparing the detected small pollution events with the historical databases of great marine accidents during 1966-2004 in European coastal waters. We show that the statistical distribution of the number of oil spills as a function of their size corresponds to Zipf's law, and that the common small spills are comparable to the large accidents due to the high frequency of the smaller pollution events. Marine pollution from tankers and ships, which has been detected as oil spills between 0.01 and 100 km 2 , follows the marine transit routes. Multi-fractal methods are used to distinguish between natural slicks and spills, in order to estimate the oil spill index in European coastal waters, and in particular, the north-western Mediterranean Sea, which, due to the influence of local winds, shows optimal conditions for oil spill detection.

  11. UMTRA project water sampling and analysis plan -- Shiprock, New Mexico

    International Nuclear Information System (INIS)

    1994-02-01

    Water sampling and analysis plan (WSAP) is required for each U.S. Department of Energy (DOE) Uranium Mill Tailings Remedial Action (UMTRA) Project site to provide a basis for ground water and surface water sampling at disposal and former processing sites. This WSAP identifies and justifies the sampling locations, analytical parameters, detection limits, and sampling frequency for the monitoring stations at the Navaho Reservation in Shiprock, New Mexico, UMTRA Project site. The purposes of the water sampling at Shiprock for fiscal year (FY) 1994 are to (1) collect water quality data at new monitoring locations in order to build a defensible statistical data base, (2) monitor plume movement on the terrace and floodplain, and (3) monitor the impact of alluvial ground water discharge into the San Juan River. The third activity is important because the community of Shiprock withdraws water from the San Juan River directly across from the contaminated alluvial floodplain below the abandoned uranium mill tailings processing site

  12. Analysis of phthalate esters contamination in drinking water samples ...

    African Journals Online (AJOL)

    The optimum condition method was successfully applied to the analysis of phthalate esters contamination in bottled drinking water samples. The concentration of DMP, DEP and DBP in drinking water samples were below allowable levels, while the DEHP concentration in three samples was found to be greater than the ...

  13. Determination of Phthalates in Drinking Water Samples

    African Journals Online (AJOL)

    user

    successfully applied to the analysis of phthalate esters contamination in bottled drinking water samples. ... esters are used in the manufacturing of polyvinyl chloride. (PVC). ... water, soil, air, food products and the human body. (Castillo et al.

  14. Climate Change and European Water Bodies, a Review of Existing Gaps and Future Research Needs: Findings of the ClimateWater Project

    Science.gov (United States)

    Garnier, Monica; Harper, David M.; Blaskovicova, Lotta; Hancz, Gabriella; Janauer, Georg A.; Jolánkai, Zsolt; Lanz, Eva; Porto, Antonio Lo; Mándoki, Monika; Pataki, Beata; Rahuel, Jean-Luc; Robinson, Victoria J.; Stoate, Chris; Tóth, Eszter; Jolánkai, Géza

    2015-08-01

    There is general agreement among scientists that global temperatures are rising and will continue to increase in the future. It is also agreed that human activities are the most important causes of these climatic variations, and that water resources are already suffering and will continue to be greatly impaired as a consequence of these changes. In particular, it is probable that areas with limited water resources will expand and that an increase of global water demand will occur, estimated to be around 35-60 % by 2025 as a consequence of population growth and the competing needs of water uses. This will cause a growing imbalance between water demand (including the needs of nature) and supply. This urgency demands that climate change impacts on water be evaluated in different sectors using a cross-cutting approach (Contestabile in Nat Clim Chang 3:11-12, 2013). These issues were examined by the EU FP7-funded Co-ordination and support action "ClimateWater" (bridging the gap between adaptation strategies of climate change impacts and European water policies). The project studied adaptation strategies to minimize the water-related consequences of climate change and assessed how these strategies should be taken into consideration by European policies. This article emphasizes that knowledge gaps still exist about the direct effects of climate change on water bodies and their indirect impacts on production areas that employ large amounts of water (e.g., agriculture). Some sectors, such as ecohydrology and alternative sewage treatment technologies, could represent a powerful tool to mitigate climate change impacts. Research needs in these still novel fields are summarized.

  15. Climate Change and European Water Bodies, a Review of Existing Gaps and Future Research Needs: Findings of the ClimateWater Project.

    Science.gov (United States)

    Garnier, Monica; Harper, David M; Blaskovicova, Lotta; Hancz, Gabriella; Janauer, Georg A; Jolánkai, Zsolt; Lanz, Eva; Lo Porto, Antonio; Mándoki, Monika; Pataki, Beata; Rahuel, Jean-Luc; Robinson, Victoria J; Stoate, Chris; Tóth, Eszter; Jolánkai, Géza

    2015-08-01

    There is general agreement among scientists that global temperatures are rising and will continue to increase in the future. It is also agreed that human activities are the most important causes of these climatic variations, and that water resources are already suffering and will continue to be greatly impaired as a consequence of these changes. In particular, it is probable that areas with limited water resources will expand and that an increase of global water demand will occur, estimated to be around 35-60% by 2025 as a consequence of population growth and the competing needs of water uses. This will cause a growing imbalance between water demand (including the needs of nature) and supply. This urgency demands that climate change impacts on water be evaluated in different sectors using a cross-cutting approach (Contestabile in Nat Clim Chang 3:11-12, 2013). These issues were examined by the EU FP7-funded Co-ordination and support action "ClimateWater" (bridging the gap between adaptation strategies of climate change impacts and European water policies). The project studied adaptation strategies to minimize the water-related consequences of climate change and assessed how these strategies should be taken into consideration by European policies. This article emphasizes that knowledge gaps still exist about the direct effects of climate change on water bodies and their indirect impacts on production areas that employ large amounts of water (e.g., agriculture). Some sectors, such as ecohydrology and alternative sewage treatment technologies, could represent a powerful tool to mitigate climate change impacts. Research needs in these still novel fields are summarized.

  16. Preconcentration NAA for simultaneous multielemental determination in water sample

    International Nuclear Information System (INIS)

    Chatt, A.

    1999-01-01

    Full text: Environment concerns with water, air, land and their interrelationship viz., human beings, fauna and flora. One of the important environmental compartments is water. Elements present in water might face a whole lot of physico-chemical conditions. This poses challenges to measure their total concentrations as well as different species. Preconcentration of the elements present in water samples is a necessary requisites in water analysis. For multi elements concentration measurements, Neutron Activation Analysis (NAA) is one of the preferred analytical techniques due to its sensitivity and selectivity. In this talk preconcentration NAA for multielemental determination in water sample determination will be discussed

  17. The European Pressurized Water Reactor. A safe and competitive solution for future energy needs

    International Nuclear Information System (INIS)

    Leverenz, R.; Gerhard, L.; Goebel, A.

    2004-01-01

    The European Pressurized Water Reactor - the EPR - is a PWR in the 1600 MW class. Its design is based on experience feedback from several thousand reactors x years of light water reactor operation worldwide, primarily those incorporating the most recent technologies: the French N4 and the German KONVOI reactors. It is an evolutionary design that ensures continuity in the mastery of PWR technology, minimizing the risk for the customer. (author)

  18. [Detection of Cryptospordium spp. in environmental water samples by FTA-PCR].

    Science.gov (United States)

    Zhang, Xiao-Ping; Zhu, Qian; He, Yan-Yan; Jiang, Li; Jiang, Shou-Fu

    2011-02-01

    To establish a FTA-polymeras chain reaction (FTA-PCR) method in detection of Cryptospordium spp. in different sources of water. The semi automated immunomagnetic separation (IMS) of Cryptospordium oocysts in environmental water samples was performed firstly, and then genomic DNA of Cryptospordium oocysts was extracted by FTA filters disk. Oligonucleotide primers were designed based on the DNA fragment of the 18 S rRNA gene from C. parvum. Plate DNA was amplified with primers in PCR. The control DNA samples from Toxoplasma gondii,Sarcocystis suihominis, Echinococcus granulosus, and Clonorchis sinensis were amplified simultaneously. All PCR products were detected by agar electrophoresis dyed with ethidium bromide. The 446 bp fragment of DNA was detected in all samples of C. parvum, C. andersoni, and C. baileyi, while it was not detected in control groups in laboratory. No positive samples were found from 10 samples collected from tape water in 5 districts of Shanghai City by FTA-PCR. Nine positive samples were detected totally from 70 different environmental water samples, there were 0 out of 15 samples from the source of tape water, 2 out of 25 from the Huangpu River, 5 out of 15 from rivers around the animal farmers, 1 out of 9 from output water of contaminating water treatment factory, 1 out of 6 from the out gate of living contaminating water. The 446 bp fragment was detected from all the amplified positive water samples. FTA-PCR is an efficient method for gene detection of Cryptospordium oocysts, which could be used in detection of environmental water samples. The contamination degree of Cryptospordium oocysts in the river water around animal farms is high.

  19. Detection of pesticides residues in water samples from organic and conventional paddy fields of Ledang, Johor, Malaysia

    Science.gov (United States)

    Abdullah, Md Pauzi; Othman, Mohamed Rozali; Ishak, Anizan; Nabhan, Khitam Jaber

    2016-11-01

    Pesticides have been used extensively by the farmers in Malaysia during the last few decades. Sixteen water samples, collected from paddy fields both organic and conventional, from Ledang, Johor, were analyzed to determine the occurrence and distribution of organochlorine (OCPs) and organophosphorus (OPPs) pesticide residues. GC-ECD instrument was used to identify and determine the concentrations of these pesticide residues. Pesticide residues were detected in conventional fields in the range about 0.036-0.508 µg/L higher than detected in organic fields about 0.015-0.428 µg/L. However the level of concentration of pesticide residues in water sample from both paddy fields are in the exceed limit for human consumption, according to European Economic Commission (EEC) (Directive 98/83/EC) at 0.1 µg/L for any pesticide or 0.5 µg/L for total pesticides. The results that the organic plot is still contaminated with pesticides although pesticides were not use at all in plot possibly from historical used as well as from airborne contamination.

  20. Carbon and water balance of European croplands throughout the 20th century

    Science.gov (United States)

    Gervois, SéBastien; Ciais, Philippe; de Noblet-Ducoudré, Nathalie; Brisson, Nadine; Vuichard, Nicolas; Viovy, Nicolas

    2008-06-01

    We assessed the effects of rising atmospheric CO2, changing climate, and farmers' practice on the carbon and water balance of European croplands during the past century (1901-2000). The coupled vegetation-crop model ORCHIDEE-STICS is applied over western Europe for C3 crops (winter wheat) and for maize, with prescribed historical agricultural practice changes. Not surprisingly, the enormous crop yield increase observed in all European regions, 300-400% between 1950 and 2000, is found to be dominantly explained by improved practice and varieties selection, rather than by rising CO2 (explaining a ˜11% uniform increase in yield) and changing climate (no further change in yield on average, but causing a decrease of ˜19% in the southern Iberian Peninsula). Agricultural soil carbon stocks in Europe are modeled to have decreased between 1950 and 1970, and since then to have increased again. Thus, the current stocks only differ by 1 ± 6 tC ha-1 from their 1900 value. Compensating effects of increasing yields on the one hand (increasing stocks) and of higher harvest index values and ploughing on the other hand (decreasing stocks) occur. Each of these processes taken individually has the potential to strongly alter the croplands soil carbon balance in the model. Consequently, large uncertainties are associated to the estimated change in carbon stocks between 1901 and 2001, roughly ±6 tC ha-1 a-1. In our most realistic simulation, the current cropland carbon balance is a net sink of 0.16 ± 0.15 tC ha-1 a-1. The annual water balance of cropland soils is influenced by increasing crop water use efficiency, one third of which is caused by rising CO2. However, increasing water use efficiency occurred mainly in spring and winter, when water is not limiting for plant growth, whereas no strong savings of soil water are achieved in summer through elevated CO2. Overall, trends in cultivation practices have caused a 3 times larger increase of water use efficiency than rising CO2.

  1. UMTRA Project water sampling and analysis plan, Gunnison, Colorado: Revision 1

    International Nuclear Information System (INIS)

    1994-11-01

    This water sampling and analysis plan summarizes the results of previous water sampling activities and the plan for future water sampling activities, in accordance with the Guidance Document for Preparing Sampling and Analysis Plans for UMTRA Sites. A buffer zone monitoring plan for the Dos Rios Subdivision is included as an appendix. The buffer zone monitoring plan was developed to ensure continued protection to the public from residual contamination. The buffer zone is beyond the area depicted as contaminated ground water due to former milling operations. Surface remedial action at the Gunnison Uranium Mill Tailings Remedial Action Project site began in 1992; completion is expected in 1995. Ground water and surface water will be sampled semiannually at the Gunnison processing site and disposal site. Results of previous water sampling at the Gunnison processing site indicate that ground water in the alluvium is contaminated by the former uranium processing activities. Background ground water conditions have been established in the uppermost aquifer at the Gunnison disposal site. The monitor well locations provide a representative distribution of sampling points to characterize ground water quality and ground water flow conditions in the vicinity of the sites. The list of analytes has been modified with time to reflect constituents that are related to uranium processing activities and the parameters needed for geochemical evaluation

  2. Monolith Chromatography as Sample Preparation Step in Virome Studies of Water Samples.

    Science.gov (United States)

    Gutiérrez-Aguirre, Ion; Kutnjak, Denis; Rački, Nejc; Rupar, Matevž; Ravnikar, Maja

    2018-01-01

    Viruses exist in aquatic media and many of them use this media as transmission route. Next-generation sequencing (NGS) technologies have opened new doors in virus research, allowing also to reveal a hidden diversity of viral species in aquatic environments. Not surprisingly, many of the newly discovered viruses are found in environmental fresh and marine waters. One of the problems in virome research can be the low amount of viral nucleic acids present in the sample in contrast to the background ones (host, eukaryotic, prokaryotic, environmental). Therefore, virus enrichment prior to NGS is necessary in many cases. In water samples, an added problem resides in the low concentration of viruses typically present in aquatic media. Different concentration strategies have been used to overcome such limitations. CIM monoliths are a new generation of chromatographic supports that due to their particular structural characteristics are very efficient in concentration and purification of viruses. In this chapter, we describe the use of CIM monolithic chromatography for sample preparation step in NGS studies targeting viruses in fresh or marine water. The step-by-step protocol will include a case study where CIM concentration was used to study the virome of a wastewater sample using NGS.

  3. Reduction of hexavalent chromium in water samples acidified for preservation

    Science.gov (United States)

    Stollenwerk, K.G.; Grove, D.B.

    1985-01-01

    Reduction of hexavalent chromium, Cr(VI), in water samples, preserved by standard techniques, was investigated. The standard preservation technique for water samples that are to be analyzed for Cr(VI) consists of filtration through a 0.45-??m membrane, acidification to a pH plastic bottles. Batch experiments were conducted to evaluate the effect of H+ concentration, NO2, temperature, and dissolved organic carbon (DOC) on the reduction of Cr(VI) to Cr(III). The rate of reduction of Cr(VI) to Cr(III) increased with increasing NO2, DOC, H+, and temperature. Reduction of Cr(VI) by organic matter occurred in some samples even though the samples were unacidified. Reduction of Cr(VI) is inhibited to an extent by storing the sample at 4??C. Stability of Cr(VI) in water is variable and depends on the other constituents present in the sample. Water samples collected for the determination of Cr(VI) should be filtered (0.45-??m membrane), refrigerated, and analyzed as quickly as possible. Water samples should not be acidified. Measurement of total Cr in addition to Cr(VI) can serve as a check for Cr(VI) reduction. If total Cr is greater than Cr(VI), the possibility that Cr(VI) reduction has occurred needs to be considered.The rate of reduction of Cr(VI) to Cr(III) increased with increasing NO//2, DOC, H** plus , and temperature. Reduction of Cr(VI) by organic matter occurred in some samples even though the samples were unacidified. Reduction of Cr(VI) is inhibited to an extent by storing the sample at 4 degree C. Stability of Cr(VI) in water is variable and depends on the other constituents present in the sample. Water samples collected for the determination of Cr(VI) should be filtered (0. 45- mu m membrane), refrigerated, and analyzed as quickly as possible. Water samples should not be acidified. Measurement of total Cr in addition to Cr(VI) can serve as a check for Cr(VI) reduction. If total Cr is greater than Cr(VI), the possibility that Cr(VI) reduction has occurred needs

  4. Microbial Condition of Water Samples from Foreign Fuel Storage Facilities

    International Nuclear Information System (INIS)

    Berry, C.J.

    1998-01-01

    In order to assess the microbial condition of foreign spent nuclear fuel storage facilities and their possible impact on SRS storage basins, twenty-three water samples were analyzed from 12 different countries. Fifteen of the water samples were analyzed and described in an earlier report (WSRC-TR-97-00365 [1]). This report describes nine additional samples received from October 1997 through March 1998. The samples include three from Australia, two from Denmark and Germany and one sample from Italy and Greece. Each water sample was analyzed for microbial content and activity as determined by total bacteria, viable aerobic bacteria, viable anaerobic bacteria, viable sulfate-reducing bacteria, viable acid-producing bacteria and enzyme diversity. The results for each water sample were then compared to all other foreign samples analyzed to date and monthly samples pulled from the receiving basin for off-site fuel (RBOF), at SRS. Of the nine samples analyzed, four samples from Italy, Germany and Greece had considerably higher microbiological activity than that historically found in the RBOF. This microbial activity included high levels of enzyme diversity and the presence of viable organisms that have been associated with microbial influenced corrosion in other environments. The three samples from Australia had microbial activities similar to that in the RBOF while the two samples from Denmark had lower levels of microbial activity. These results suggest that a significant number of the foreign storage facilities have water quality standards that allow microbial proliferation and survival

  5. Press kit. EPR (European pressurized water reactor). The advanced nuclear reactor

    International Nuclear Information System (INIS)

    2004-10-01

    Nuclear energy, which provides a steady supply of electricity at low cost, has its rightful place in the energy mix of the 21 century, which puts the emphasis on sustainable development. In this framework, this document presents the advantages of the EPR (European Pressurized water Reactor). The EPR is the only third generation reactor under construction today. It is an evolutionary reactor that represents a new generation of pressurized water reactors with no break in the technology used for the most recent models. The EPR can guarantee a safe, inexpensive electricity supply, without adding to the greenhouse effect. It meets the requirements of the safety authorities and lives up to the expectations of electricity utilities. (A.L.B.)

  6. Sampling procedure for lake or stream surface water chemistry

    Science.gov (United States)

    Robert Musselman

    2012-01-01

    Surface waters collected in the field for chemical analyses are easily contaminated. This research note presents a step-by-step detailed description of how to avoid sample contamination when field collecting, processing, and transporting surface water samples for laboratory analysis.

  7. Saving the Planet’s Climate or Water Resources? The Trade-Off between Carbon and Water Footprints of European Biofuels

    Directory of Open Access Journals (Sweden)

    Markus Berger

    2015-05-01

    Full Text Available Little information regarding the global water footprint of biofuels consumed in Europe is available. Therefore, the ultimate origin of feedstock underlying European biodiesel and bioethanol consumption was investigated and combined with the irrigation requirements of different crops in different countries. A (blue water consumption of 1.9 m3 in 12 countries per GJ of European biodiesel and 3.3 m3 in 23 countries per GJ of bioethanol was determined. Even though this represents an increase by a factor of 60 and 40 compared to fossil diesel and gasoline, these figures are low compared to global average data. The assessment of local consequences has shown that the irrigation of sunflower seed in Spain causes 50% of the impacts resulting from biodiesel—even though it constitutes only 0.9% of the feedstock. In case of bioethanol production, the irrigation of sugar cane in Egypt, which constitutes only 0.7% of the underlying feedstock, causes 20% of the impacts. In a case study on passenger cars, it was shown that biofuels can reduce the global warming potential by circa 50% along the product life cycle. However, the price of this improvement is an approximate 19 times increased water consumption, and resulting local impacts are even more severe.

  8. Analytical study on the determination of boron in environmental water samples

    International Nuclear Information System (INIS)

    Lopez, F.J.; Gimenez, E.; Hernandez, F.

    1993-01-01

    An analytical study on the determination of boron in environmental water samples was carried out. The curcumin and carmine standard methods were compared with the most recent Azomethine-H method in order to evaluate their analytical characteristics and feasibility for the analysis of boron in water samples. Analyses of synthetic water, ground water, sea water and waste water samples were carried out and a statistical evaluation of the results was made. The Azomethine-H method was found to be the most sensitive (detection limit 0.02 mg l -1 ) and selective (no interference of commonly occurring ions in water was observed), showing also the best precision (relative standard deviation lower than 4%). Moreover, it gave good results for all types of samples analyzed. The accuracy of this method was tested by the addition of known amounts of standard solutions to different types of water samples. The slopes of standard additions and direct calibration graphs were similar and recoveries of added boron ranged from 99 to 107%. (orig.)

  9. Heel blood sampling in European neonatal intensive care units: compliance with pain management guidelines

    DEFF Research Database (Denmark)

    Losacco, Valentina; Cuttini, Marina; Greisen, Gorm

    2011-01-01

    Objective To describe the use of heel blood sampling and non-pharmacological analgesia in a large representative sample of neonatal intensive care units (NICUs) in eight European countries, and compare their self-reported practices with evidence-based recommendations. Methods Information on use...... of heel blood sampling and associated procedures (oral sweet solutions, non-nutritive sucking, swaddling or positioning, topical anaesthetics and heel warming) were collected through a structured mail questionnaire. 284 NICUs (78% response rate) participated, but only 175 with >/=50 very low birth weight...... admissions per year were included in this analysis. Results Use of heel blood sampling appeared widespread. Most units in the Netherlands, UK, Denmark, Sweden and France predominantly adopted mechanical devices, while manual lance was still in use in the other countries. The two Scandinavian countries...

  10. UMTRA Project water sampling and analysis plan, Gunnison, Colorado. Revision 2

    International Nuclear Information System (INIS)

    1995-09-01

    Surface remedial action at the Gunnison Uranium Mill Tailings Remedial Action Project site began in 1992; completion is expected in 1995. Ground water and surface water will be sampled semiannually at the Gunnison processing site (GUN-01) and disposal site (GUN-08). Results of previous water sampling at the Gunnison processing site indicate that ground water in the alluvium is contaminated by the former uranium processing activities. Background ground water conditions have been established in the uppermost aquifer (Tertiary gravels) at the Gunnison disposal site. Semiannual water sampling is scheduled for the spring and fall. Water quality sampling is conducted at the processing site (1) to ensure protection of human health and the environment, (2) for ground water compliance monitoring during remedial action construction, and (3) to define the extent of contamination. At the processing site, the frequency and duration of sampling will be dependent upon the nature and extent of residual contamination and the compliance strategy chosen. The monitor well locations provide a representative distribution of sampling points to characterize ground water quality and ground water flow conditions in the vicinity of the sites. The list of analytes has been modified with time to reflect constituents that are related to uranium processing activities and the parameters needed for geochemical evaluation

  11. Leaf gas exchange performance and the lethal water potential of five European species during drought.

    Science.gov (United States)

    Li, Shan; Feifel, Marion; Karimi, Zohreh; Schuldt, Bernhard; Choat, Brendan; Jansen, Steven

    2016-02-01

    Establishing physiological thresholds to drought-induced mortality in a range of plant species is crucial in understanding how plants respond to severe drought. Here, five common European tree species were selected (Acer campestre L., Acer pseudoplatanus L., Carpinus betulus L., Corylus avellana L. and Fraxinus excelsior L.) to study their hydraulic thresholds to mortality. Photosynthetic parameters during desiccation and the recovery of leaf gas exchange after rewatering were measured. Stem vulnerability curves and leaf pressure-volume curves were investigated to understand the hydraulic coordination of stem and leaf tissue traits. Stem and root samples from well-watered and severely drought-stressed plants of two species were observed using transmission electron microscopy to visualize mortality of cambial cells. The lethal water potential (ψlethal) correlated with stem P99 (i.e., the xylem water potential at 99% loss of hydraulic conductivity, PLC). However, several plants that were stressed beyond the water potential at 100% PLC showed complete recovery during the next spring, which suggests that the ψlethal values were underestimated. Moreover, we observed a 1 : 1 relationship between the xylem water potential at the onset of embolism and stomatal closure, confirming hydraulic coordination between leaf and stem tissues. Finally, ultrastructural changes in the cytoplasm of cambium tissue and mortality of cambial cells are proposed to provide an alternative approach to investigate the point of no return associated with plant death. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  12. UMTRA project water sampling and analysis plan, Monument Valley, Arizona

    International Nuclear Information System (INIS)

    1994-04-01

    The Monument Valley Uranium Mill Tailings Remedial Action (UMTRA) Project site in Cane Valley is a former uranium mill that has undergone surface remediation in the form of tailings and contaminated materials removal. Contaminated materials from the Monument Valley (Arizona) UMTRA Project site have been transported to the Mexican Hat (Utah) UMTRA Project site for consolidation with the Mexican Hat tailings. Tailings removal was completed in February 1994. Three geologic units at the site contain water: the unconsolidated eolian and alluvial deposits (alluvial aquifer), the Shinarump Conglomerate (Shinarump Member), and the De Chelly Sandstone. Water quality analyses indicate the contaminant plume has migrated north of the site and is mainly in the alluvial aquifer. An upward hydraulic gradient in the De Chelly Sandstone provides some protection to that aquifer. This water sampling and analysis plan recommends sampling domestic wells, monitor wells, and surface water in April and September 1994. The purpose of sampling is to continue periodic monitoring for the surface program, evaluate changes to water quality for site characterization, and provide data for the baseline risk assessment. Samples taken in April will be representative of high ground water levels and samples taken in September will be representative of low ground water levels. Filtered and nonfiltered samples will be analyzed for plume indicator parameters and baseline risk assessment parameters

  13. PIXE analysis applied to characterized water samples

    International Nuclear Information System (INIS)

    Santos, Maristela S.; Carneiro, Luana Gomes; Medeiros, Geiza; Sampaio, Camilla; Martorell, Ana Beatriz Targino; Gouvea, Stella; Cunha, Kenya Moore Dias da

    2011-01-01

    Araxa, in Brazil, is a naturally high background area located in the State of Minas Gerais with a population of about 93 672 people. Araxa is historical city famous for its mineral water sources and mud from Termas de Araxa spa, which have been used for therapeutic, and recreation purposes. Other important aspect of economy of the city are mining and metallurgic industries. In the Araxa area is located the largest deposit of pyrochlore, a niobium mineral, and also a deposit of apatite, a phosphate mineral both containing Th and U associated to crystal lattice. The minerals are obtained from open pit mines, the minerals are processed in industrial also located in city of Araxa, these plants process the pyrochlore and apatite to obtain the Fe-Nb alloy and the concentrate of phosphate, respectively. Studies were developed in this area to assessment the occupational risk of the workers due to exposure to dust particles during the routine working, however very few studies evaluated the water contamination outside the mines in order to determine the metal (stables elements) concentrations in water and also the concentrations of the radionuclides in water. This paper presents the previous results of a study to identify and determine the concentrations of metals (stables elements) and radionuclides in river around the city. The water from these rivers is used as drinking water and irrigation water. The water samples were collected in different rivers around the Araxa city and the samples were analyzed using PIXE technique. A proton beam of 2 MeV obtained from the van de Graaff electrostatic accelerator was used to induce the characteristic X-rays. S, K, Ca, Cr, Mn, Fe, Ni, Zn, Ba, Pb and U were identified in the mass spectrum of the samples. The elemental mass concentrations were compared using a non-parametric statistical test. The results of the statistical test showed that the elemental mass concentrations did not present the same distribution. These results indicated

  14. European identity: A lot of water will pass...

    Directory of Open Access Journals (Sweden)

    Šuvaković Uroš V.

    2015-01-01

    Full Text Available The basic problem that the process of Euro integrations faces today is the absence of the European identity. There are ideas how it could be built, on what it should be based, but the basic problem is the EU has give up in a great extent from the real European values - the ideals like freedom, equality, solidarity, social justice, etc. Human rights are the European achievement, but a distinctive, therefore identity difference between the European and the Anglo-American interpretation is that the European variant guaranteed social-economic rights, which was actually a concretization of the great ideal of solidarity. Today, with prevailing ideology of globalism, just this element of human rights has been brutally waded, a part of the European identity with it. A similar situation is with what the Europeans consider the greatest achievement of the EU - free movement of people, goods and capital. Free movement of people is questioned by building barbed wires and creation of a new ante murale christianitatis, even in Islamic states, far away from the Schengen Area that is proclaimed untouchable. Moreover, all those people swarming to the Europe actually have close connections with it - they originate from former European colonies, brutally exploited by their metropolises for decades and centuries. Not only that, but recently their new 'Europeanization' has been attempted through the initialization of the 'Arab Spring' , which resulted with increase of the Islamic fundamentalism, disintegration of certain Arab states and tribal war in them, increase of terrorism and, of course, migrants from those areas. Although it would be justified to try to return the evil gotten to them at least partly, by refusing to accept the miserable the Europe gives the mortal strike to some of the main values that are considered its identity characteristics - free movement of people and solidarity. All this, actually, indicates on the absence of the European identity

  15. Mass transfer of H2O between petroleum and water: implications for oil field water sample quality

    International Nuclear Information System (INIS)

    McCartney, R.A.; Ostvold, T.

    2005-01-01

    Water mass transfer can occur between water and petroleum during changes in pressure and temperature. This process can result in the dilution or concentration of dissolved ions in the water phase of oil field petroleum-water samples. In this study, PVT simulations were undertaken for 4 petroleum-water systems covering a range of reservoir conditions (80-185 o C; 300-1000 bar) and a range of water-petroleum mixtures (volume ratios of 1:1000-300:1000) to quantify the extent of H 2 O mass transfer as a result of pressure and temperature changes. Conditions were selected to be relevant to different types of oil field water sample (i.e. surface, downhole and core samples). The main variables determining the extent of dilution and concentration were found to be: (a) reservoir pressure and temperature, (b) pressure and temperature of separation of water and petroleum, (c) petroleum composition, and (d) petroleum:water ratio (PWR). The results showed that significant dilution and concentration of water samples could occur, particularly at high PWR. It was not possible to establish simple guidelines for identifying good and poor quality samples due to the interplay of the above variables. Sample quality is best investigated using PVT software of the type used in this study. (author)

  16. Estimates of microbial quality and concentration of copper in distributed drinking water are highly dependent on sampling strategy.

    Science.gov (United States)

    Lehtola, Markku J; Miettinen, Ilkka T; Hirvonen, Arja; Vartiainen, Terttu; Martikainen, Pertti J

    2007-12-01

    The numbers of bacteria generally increase in distributed water. Often household pipelines or water fittings (e.g., taps) represent the most critical location for microbial growth in water distribution systems. According to the European Union drinking water directive, there should not be abnormal changes in the colony counts in water. We used a pilot distribution system to study the effects of water stagnation on drinking water microbial quality, concentration of copper and formation of biofilms with two commonly used pipeline materials in households; copper and plastic (polyethylene). Water stagnation for more than 4h significantly increased both the copper concentration and the number of bacteria in water. Heterotrophic plate counts were six times higher in PE pipes and ten times higher in copper pipes after 16 h of stagnation than after only 40 min stagnation. The increase in the heterotrophic plate counts was linear with time in both copper and plastic pipelines. In the distribution system, bacteria originated mainly from biofilms, because in laboratory tests with water, there was only minor growth of bacteria after 16 h stagnation. Our study indicates that water stagnation in the distribution system clearly affects microbial numbers and the concentration of copper in water, and should be considered when planning the sampling strategy for drinking water quality control in distribution systems.

  17. Water sampling device for detecting fuel failure

    International Nuclear Information System (INIS)

    Masubuchi, Yukio.

    1997-01-01

    A notched portion is formed at the lower end of an outer cap, and an extensible air bag is disposed being in contact with the inner side of the notched portion. A compressed air is sent into the outer gap through an air supply pipe to urge coolants thereby lowering the water level. A portion of the compressed air gets out of the outer gap from the notched portion, and if air bubbles are observed on the surface of coolants in a pressure vessel of a reactor, the outer cap is confirmed to be attached to the upper lattice plate. Compressed air is supplied to the air bag to close the notched portion. Then, coolants are sucked from a water level confirmation pipe. The level of coolants is further lowered, and the compressed air is sucked from the water level confirmation pipe instead of the coolants. Then, the level of the coolants at the inner side of the inner cap is confirmed to be made lower than the upper end of the channel box of a reactor fuel assembly. Then, coolants in the channel box are sampled, as a specimen water, through a water sampling pipe. (I.N.)

  18. UMTRA project water sampling and analysis plan, Tuba City, Arizona

    International Nuclear Information System (INIS)

    1996-02-01

    Planned, routine ground water sampling activities at the U.S. Department of Energy (DOE) Uranium Mill Tailings Remedial Action (UMTRA) Project site in Tuba City, Arizona, are described in the following sections of this water sampling and analysis plan (WSAP). This plan identifies and justifies the sampling locations, analytical parameters, detection limits, and sampling frequency for the stations routinely monitored at the site. The ground water data are used for site characterization and risk assessment. The regulatory basis for routine ground water monitoring at UMTRA Project sites is derived from the U.S. Environmental Protection Agency (EPA) regulations in 40 CFR Part 192 (1994) and the final EPA standards of 1995 (60 FR 2854). Sampling procedures are guided by the UMTRA Project standard operating procedures (SOP) (JEG, n.d.), and the most effective technical approach for the site

  19. European CO2 emission trends: A decomposition analysis for water and aviation transport sectors

    International Nuclear Information System (INIS)

    Andreoni, V.; Galmarini, S.

    2012-01-01

    A decomposition analysis is used to investigate the main factors influencing the CO 2 emissions of European transport activities for the period 2001–2008. The decomposition method developed by Sun has been used to investigate the carbon dioxide emissions intensity, the energy intensity, the structural changes and the economy activity growth effects for the water and the aviation transport sectors. The analysis is based on Eurostat data and results are presented for 14 Member States, Norway and EU27. Results indicate that economic growth has been the main factor behind the carbon dioxide emissions increase in EU27 both for water and aviation transport activities. -- Highlights: ► Decomposition analysis is used to investigate factors that influenced the energy-related CO 2 emissions of European transport. ► Economic growth has been the main factor affecting the energy-related CO 2 emissions increases. ► Investigating the CO 2 emissions drivers is the first step to define energy efficiency policies and emission reduction strategies.

  20. Organophosphorus and Carbamate Pesticide Residues Detected in Water Samples Collected from Paddy and Vegetable Fields of the Savar and Dhamrai Upazilas in Bangladesh

    Directory of Open Access Journals (Sweden)

    Nurul Karim

    2012-09-01

    Full Text Available Several types of organophosphorous and carbamate pesticides have been used extensively by the farmers in Bangladesh during the last few decades. Twenty seven water samples collected from both paddy and vegetable fields in the Savar and Dhamrai Upazilas in Bangladesh were analyzed to determine the occurrence and distribution of organo-phosphorus (chlorpyrifos, malathion and diazinon and carbamate (carbaryl and carbofuran pesticide residues. A high performance liquid chromatograph instrument equipped with a photodiode array detector was used to determine the concentrations of these pesticide residues. Diazinon and carbofuran were detected in water samples collected from Savar Upazila at 0.9 μg/L and 198.7 μg/L, respectively. Malathion was also detected in a single water sample at 105.2 μg/L from Dhamrai Upazila. Carbaryl was the most common pesticide detected in Dhamrai Upazila at 14.1 and 18.1 μg/L, while another water sample from Dhamrai Upazila was contaminated with carbofuran at 105.2 μg/L. Chlorpyrifos was not detected in any sample. Overall, the pesticide residues detected were well above the maximum acceptable levels of total and individual pesticide contamination, at 0.5 and 0.1 μg/L, respectively, in water samples recommended by the European Economic Community (Directive 98/83/EC. The presence of these pesticide residues may be attributed by their intense use by the farmers living in these areas. Proper handling of these pesticides should be ensured to avoid direct or indirect exposure to these pesticides.

  1. UMTRA project water sampling and analysis plan, Grand Junction, Colorado

    International Nuclear Information System (INIS)

    1994-07-01

    Surface remedial action will be completed at the Grand Junction processing site during the summer of 1994. Results of 1993 water sampling indicate that ground water flow conditions and ground water quality at the processing site have remained relatively constant with time. Uranium concentrations in ground water continue to exceed the maximum concentration limits, providing the best indication of the extent of contaminated ground water. Evaluation of surface water quality of the Colorado River indicate no impact from uranium processing activities. No compliance monitoring at the Cheney disposal site has been proposed because ground water in the Dakota Sandstone (uppermost aquifer) is classified as limited-use (Class 111) and because the disposal cell is hydrogeologically isolated from the uppermost aquifer. The following water sampling and water level monitoring activities are planned for calendar year 1994: (i) Semiannual (early summer and late fall) sampling of six existing monitor wells at the former Grand Junction processing site. Analytical results from this sampling will be used to continue characterizing hydrogeochemical trends in background ground water quality and in the contaminated ground water area resulting from source term (tailings) removal. (ii) Water level monitoring of approximately three proposed monitor wells projected to be installed in the alluvium at the processing site in September 1994. Data loggers will be installed in these wells, and water levels will be electronically monitored six times a day. These long-term, continuous ground water level data will be collected to better understand the relationship between surface and ground water at the site. Water level and water quality data eventually will be used in future ground water modeling to establish boundary conditions in the vicinity of the Grand Junction processing site. Modeling results will be used to help demonstrate and document the potential remedial alternative of natural flushing

  2. Water resources management and European integration of Serbia

    Directory of Open Access Journals (Sweden)

    Todić Dragoljub

    2015-01-01

    Full Text Available The paper points to the main elements important for understanding the obligations arising from the process of accession of the Republic of Serbia (RS to the European Union (EU as related to water resources management. The general framework is determined by the importance of water resources for contemporary international relations as well as the rules governing the process of harmonizing the national legislation with the EU legislation. This paper provides an overview of the most important regulations of the RS and the EU in the field of water resources management, including its status in international treaties. Drawing upon the rules governing the harmonization process, the paper provides indicators of the achieved level of compliance of national legislation with key EU regulations in the field of water resources management. The provided analysis is based on the premise that the process of joining the EU is the main factor that determines the current position and policy of RS in the field of water resources management. In that context, management of water resources falls into the group of EU regulations which are, within the framework of Chapter 27, most difficult to transpose and apply in the internal legal system. Although the process of harmonizing the national legislation with the EU legislation has been underway as regards a vast number of regulations, the process of reaching full compliance is likely to take a couple of years. Concurrently, it has been estimated that the full implementation of legislation harmonized with the EU legislation will take at least two decades, primarily due to the substantial financial resources to be invested in the development of water infrastructure. In terms of participation in the activities undertaken within the framework of international agreements in the field of water resources management and the state's membership in relevant international treaties, it is noted that in the last decade the RS has

  3. UMTRA project water sampling and analysis plan, Mexican Hat, Utah

    International Nuclear Information System (INIS)

    1994-04-01

    The Mexican Hat, Utah, Uranium Mill Tailings Remedial Action (UMTRA) Project site is a former uranium mill that is undergoing surface remediation in the form of on-site tailings stabilization. Contaminated surface materials from the Monument Valley, Arizona, UMTRA Project site have been transported to the Mexican Hat site and are being consolidated with the Mexican Hat tailings. The scheduled completion of the tailings disposal cell is August 1995. Water is found in two geologic units at the site: the Halgaito Shale Formation and the Honaker Trail Formation. The tailings rest on the Halgaito Shale, and water contained in that unit is a result of milling activities and, to a lesser extent, water released from the tailings from compaction during remedial action construction of the disposal cell. Water in the Halgaito Shale flows through fractures and discharges at seeps along nearby arroyos. Flow from the seeps will diminish as water drains from the unit. Ground water in the lower unit, the Honaker Trail Formation, is protected from contamination by an upward hydraulic gradient. There are no nearby water supply wells because of widespread poor background ground water quality and quantity, and the San Juan River shows no impacts from the site. This water sampling and analysis plan (WSAP) recommends sampling six seeps and one upgradient monitor well compared in the Honaker Trail Formation. Samples will be taken in April 1994 (representative of high group water levels) and September 1994 (representative of low ground water levels). Analyses will be performed on filtered samples for plume indicator parameters

  4. Uranium content measurement in drinking water samples using track etch technique

    International Nuclear Information System (INIS)

    Kumar, Mukesh; Kumar, Ajay; Singh, Surinder; Mahajan, R.K.; Walia, T.P.S.

    2003-01-01

    The concentration of uranium has been assessed in drinking water samples collected from different locations in Bathinda district, Punjab, India. The water samples are taken from hand pumps and tube wells. Uranium is determined using fission track technique. Uranium concentration in the water samples varies from 1.65±0.06 to 74.98±0.38 μg/l. These values are compared with safe limit values recommended for drinking water. Most of the water samples are found to have uranium concentration above the safe limit. Analysis of some heavy metals (Zn, Cd, Pb and Cu) in water is also done in order to see if some correlation exists between the concentration of uranium and these heavy metals. A weak positive correlation has been observed between the concentration of uranium and heavy metals of Pb, Cd and Cu

  5. Impacts of European livestock production: nitrogen, sulphur, phosphorus and greenhouse gas emissions, land-use, water eutrophication and biodiversity

    International Nuclear Information System (INIS)

    Leip, Adrian; Grizzetti, Bruna; Weiss, Franz; Billen, Gilles; Garnier, Josette; Lassaletta, Luis; Reis, Stefan; Sutton, Mark A; Simpson, David; De Vries, Wim; Westhoek, Henk

    2015-01-01

    Livestock production systems currently occupy around 28% of the land surface of the European Union (equivalent to 65% of the agricultural land). In conjunction with other human activities, livestock production systems affect water, air and soil quality, global climate and biodiversity, altering the biogeochemical cycles of nitrogen, phosphorus and carbon. Here, we quantify the contribution of European livestock production to these major impacts. For each environmental effect, the contribution of livestock is expressed as shares of the emitted compounds and land used, as compared to the whole agricultural sector. The results show that the livestock sector contributes significantly to agricultural environmental impacts. This contribution is 78% for terrestrial biodiversity loss, 80% for soil acidification and air pollution (ammonia and nitrogen oxides emissions), 81% for global warming, and 73% for water pollution (both N and P). The agriculture sector itself is one of the major contributors to these environmental impacts, ranging between 12% for global warming and 59% for N water quality impact. Significant progress in mitigating these environmental impacts in Europe will only be possible through a combination of technological measures reducing livestock emissions, improved food choices and reduced food waste of European citizens. (letter)

  6. Tracer element studies on deep water formation and circulation in the European Artic Sea

    International Nuclear Information System (INIS)

    Boenisch, G.

    1991-01-01

    Tracer element investigations (tritium, helium 3, carbon 14, argon 39, krypton 85 and fluorohydrocarbons) were carried out in the European Arctic Sea. The findings are discussed with a view to their validity in the case of deep water formation and circulation. The data cover the period of 1972 through 1989. (BBR) [de

  7. Determination of Phenols in Water Samples using a Supported ...

    African Journals Online (AJOL)

    The sample preparation method was tested for the determination of phenols in river water samples and landfill leachate. Concentrations of phenols in river water were found to be in the range 4.2 μg L–1 for 2-chlorophenol to 50 μg L–1 for 4-chlorophenol. In landfill leachate, 4-chlorophenol was detected at a concentration ...

  8. UMTRA Project water sampling and analysis plan, Durango, Colorado. Revision 1

    International Nuclear Information System (INIS)

    1995-09-01

    Planned, routine ground water sampling activities at the US Department of Energy (DOE) Uranium Mill Tailings Remedial Action (UMTRA) Project site in Durango, Colorado, are described in this water sampling and analysis plan. The plan identifies and justifies the sampling locations, analytical parameters, detection limits, and sampling frequency for the routine monitoring stations at the site. The ground water data are used to characterize the site ground water compliance strategies and to monitor contaminants of potential concern identified in the baseline risk assessment (DOE, 1995a). Regulatory basis for routine ground water monitoring at UMTRA Project sites is derived from the US EPA regulations in 40 CFR Part 192 (1994) and EPA standards of 1995 (60 FR 2854). Sampling procedures are guided by the UMTRA Project standard operating procedures (SOP) (JEG, n.d.), the Technical Approach Document (TAD) (DOE, 1989), and the most effective technical approach for the site

  9. chemical and microbiological assessment of surface water samples

    African Journals Online (AJOL)

    PROF EKWUEME

    were investigated in this study: Nine samples from different surface water bodies, two samples from two effluent sources ... Ezeagu, Udi, Nkanu, Oji River and some parts of Awgu and Aninri ..... Study of Stream Output from Small Catchments.

  10. UMTRA Project water sampling and analysis plan, Belfield and Bowman, North Dakota

    International Nuclear Information System (INIS)

    1994-08-01

    Surface remedial action is scheduled to begin at the Belfield and Bowman Uranium Mill Tailings Remedial Action (UMTRA) Project sites in the spring of 1996. Water sampling was conducted in 1993 at both the Belfield processing site and the Bowman processing/disposal site. Results of the sampling at both sites indicate that ground water conditions have remained relatively stable over time. Water sampling activities are not scheduled for 1994 because ground water conditions at the two sites are relatively stable, the 1993 sampling was comprehensive, and surface remediation activities are not scheduled to start until 1996. The next water sampling event is scheduled before the start of remedial activities and will include sampling selected monitor wells at both sites and several domestic wells in the vicinity

  11. UMTRA project water sampling and analysis plan, Salt Lake City, Utah

    International Nuclear Information System (INIS)

    1994-06-01

    Surface remedial action was completed at the Salt Lake City, Utah, Uranium Mill Tailings Remedial Action (UMTRA) Project site in the fall of 1987. Results of water sampling for the years 1992 to 1994 indicate that site-related ground water contamination occurs in the shallow unconfined aquifer (the uppermost aquifer). With respect to background ground water quality, contaminated ground water in the shallow, unconfined aquifer has elevated levels of chloride, sodium, sulfate, total dissolved solids, and uranium. No contamination associated with the former tailings pile occurs in levels exceeding background in ground water in the deeper confined aquifer. This document provides the water sampling and analysis plan for ground water monitoring at the former uranium processing site in Salt Lake City, Utah (otherwise known as the ''Vitro'' site, named after the Vitro Chemical Company that operated the mill). All contaminated materials removed from the processing site were relocated and stabilized in a disposal cell near Clive, Utah, some 85 miles west of the Vitro site (known as the ''Clive'' disposal site). No ground water monitoring is being performed at the Clive disposal site, since concurrence of the remedial action plan by the US Nuclear Regulatory Commission and completion of the disposal cell occurred before the US Environmental Protection Agency issued draft ground water standards in 1987 (52 FR 36000) for cleanup, stabilization, and control of residual radioactive materials at the disposal site. In addition, the likelihood of post-closure impact on the ground water is minimal to nonexistent, due to the naturally poor quality of the ground water. Water sampling activities planned for calendar year 1994 consist of sampling ground water from nine monitor wells to assess the migration of contamination within the shallow unconfined aquifer and sampling ground water from two existing monitor wells to assess ground water quality in the confined aquifer

  12. The collection and field chemical analysis of water samples

    International Nuclear Information System (INIS)

    Korte, N.E.; Ealey, D.T.; Hollenbach, M.H.

    1984-01-01

    A successful water sampling program requires a clear understanding of appropriate measurement and sampling procedures in order to obtain reliable field data and representative samples. It is imperative that the personnel involved have a thorough knowledge of the limitations of the techniques being used. Though this seems self-evident, many sampling and field-chemical-analysis programs are still not properly conducted. Recognizing these problems, the Department of Energy contracted with Bendix Field Engineering Corporation through the Technical Measurements Center to develop and select procedures for water sampling and field chemical analysis at waste sites. The fundamental causese of poor field programs are addressed in this paper, largely through discussion of specific field-measurement techniques and their limitations. Recommendations for improvement, including quality-assurance measures, are also presented

  13. European brown hare syndrome virus in free-ranging European brown hares from Argentina

    DEFF Research Database (Denmark)

    Frolich, K.; Kujawski, G.E.J.G.; Rudolph, M.

    2003-01-01

    From 1998 to 2000, serum samples of 80 shot European brown hares (Lepus europaeus) from Argentina were examined for antibodies against European brown hare syndrome virus (EBHSV) and 80 spleen samples were tested for EBHSV-antigen by enzyme linked immunosorbent assay (ELISA). Nine hares were posit...... in these hares. This is the first report of antibodies to EBHSV, EBHSV-antigen, and electron microscopy findings in free-ranging European brown hares from South America....

  14. Pesticide residues analysis in water samples of Nagarpur and Saturia Upazila, Bangladesh

    Science.gov (United States)

    Hasanuzzaman, M.; Rahman, M. A.; Islam, M. S.; Salam, M. A.; Nabi, M. R.

    2018-03-01

    Pesticides used to protect the crops from pest attack in the agricultural fields pose harmful effect to the non-target organisms such as human and many other aquatic and terrestrial organisms either directly or indirectly through food chain. The present study was conducted to monitor a total of seven pesticide residues under organochlorine, organophosphorus and carbamate pesticides in three different sources of pond water, paddy field water and tube-well water from Nagarpur Upazila and paddy field water in the company of Dhaleshwari and Gazikhali river water from Saturia Upazila, Bangladesh. A total of 40 water samples were analyzed using high-performance liquid chromatography equipped with ultraviolet detector. Among the organophosphorus pesticides, diazinon was detected in eight water samples at a concentration ranging from 4.11 to 257.91 μg/l whereas, malathion was detected only in one water sample at a concentration of 84.64 μg/l and chlorpyrifos pesticide was also detected only in one water sample and the concentration was 37.3 μg/l. Trace amount of carbaryl was identified but it was below the detection limit. None of the tested water samples was found to be contaminated with DDT or its metabolites (DDE and DDD). The water samples contaminated with the suspected pesticides were above the acceptable limit except for the fish pond samples of Sahabatpur and Dubaria union. To control the misuse of pesticides and to reduce the possible health risk, appropriate control systems of pests such as integrated pest management system should be implemented immediately by the authorities of the country.

  15. bacteriological analysis of well water samples in sagamu.

    African Journals Online (AJOL)

    Dr Oboro VO

    Department of Pharmaceutical Microbiology, Faculty of Pharmacy, Olabisi Onabanjo University, Ago-Iwoye, Nigeria. *Correspondence. ... All the water samples exceeded the standard limit of the most probable ... or disinfection and this could lead to outbreak of water borne diseases. ... The bottle was brought up to a surface.

  16. Comparative Study of Radon Concentration with Two Techniques and Elemental Analysis in Drinking Water Samples of the Jammu District, Jammu and Kashmir, India.

    Science.gov (United States)

    Kumar, Ajay; Kaur, Manpreet; Mehra, Rohit; Sharma, Dinesh Kumar; Mishra, Rosaline

    2017-10-01

    The level of radon concentration has been assessed using the Advanced SMART RnDuo technique in 30 drinking water samples from Jammu district, Jammu and Kashmir, India. The water samples were collected from wells, hand pumps, submersible pumps, and stored waters. The randomly obtained 14 values of radon concentration in water sources using the SMART RnDuo technique have been compared and cross checked by a RAD7 device. A good positive correlation (R = 0.88) has been observed between the two techniques. The overall value of radon concentration in various water sources has ranged from 2.45 to 18.43 Bq L, with a mean value of 8.24 ± 4.04 Bq L, and it agreed well with the recommended limit suggested by the European Commission and UNSCEAR. However, the higher activity of mean radon concentration was found in groundwater drawn from well, hand and submersible pumps as compared to stored water. The total annual effective dose due to radon inhalation and ingestion ranged from 6.69 to 50.31 μSv y with a mean value of 22.48 ± 11.03 μSv y. The total annual effective dose was found to lie within the safe limit (100 μSv y) suggested by WHO. Heavy metal analysis was also carried out in various water sources by using an atomic absorption spectrophotometer (AAS), and the highest value of heavy metals was found mostly in groundwater samples. The obtained results were compared with Indian and International organizations like WHO and the EU Council. Among all the samples, the elemental analysis is not on the exceeding side of the permissible limit.

  17. Radioactivity in waste water samples from COGEMA supplied by Greenpeace

    International Nuclear Information System (INIS)

    Reinen, H.A.J.M.; Kwakman, P.J.M.; Overwater, R.M.W.; Tax, R.B.; Nissan, L.A.

    1999-01-01

    The environmental organization Greenpeace sampled waste water from the reprocessing plant COGEMA in La Hague, France, in May 1999. On request of the Inspection Environmental Hygiene, The Dutch National Institute for Public Health and Environmental Protection (RIVM) determined the radioactivity of the waste water samples. 5 refs

  18. Effect of spatial sampling from European flux towers for estimating carbon and water fluxes with artificial neural network

    DEFF Research Database (Denmark)

    Papale, D.; Black, T Andrew; Carvalhais, Nuno

    2015-01-01

    -output relationships, while prediction for conditions outside the training domain is generally uncertain. In this work, artificial neural networks (ANNs) were used for the prediction of gross primary production (GPP) and latent heat flux (LE) on local and European scales with the aim to assess the portion...

  19. Water Intake and Hydration Indices in Healthy European Adults: The European Hydration Research Study (EHRS).

    Science.gov (United States)

    Malisova, Olga; Athanasatou, Adelais; Pepa, Alex; Husemann, Marlien; Domnik, Kirsten; Braun, Hans; Mora-Rodriguez, Ricardo; Ortega, Juan F; Fernandez-Elias, Valentin E; Kapsokefalou, Maria

    2016-04-06

    Hydration status is linked with health, wellness, and performance. We evaluated hydration status, water intake, and urine output for seven consecutive days in healthy adults. Volunteers living in Spain, Germany, or Greece (n = 573, 39 ± 12 years (51.1% males), 25.0 ± 4.6 kg/m² BMI) participated in an eight-day study protocol. Total water intake was estimated from seven-day food and drink diaries. Hydration status was measured in urine samples collected over 24 h for seven days and in blood samples collected in fasting state on the mornings of days 1 and 8. Total daily water intake was 2.75 ± 1.01 L, water from beverages 2.10 ± 0.91 L, water from foods 0.66 ± 0.29 L. Urine parameters were: 24 h volume 1.65 ± 0.70 L, 24 h osmolality 631 ± 221 mOsmol/kg Η2Ο, 24 h specific gravity 1.017 ± 0.005, 24 h excretion of sodium 166.9 ± 54.7 mEq, 24 h excretion of potassium 72.4 ± 24.6 mEq, color chart 4.2 ± 1.4. Predictors for urine osmolality were age, country, gender, and BMI. Blood indices were: haemoglobin concentration 14.7 ± 1.7 g/dL, hematocrit 43% ± 4% and serum osmolality 294 ± 9 mOsmol/kg Η2Ο. Daily water intake was higher in summer (2.8 ± 1.02 L) than in winter (2.6 ± 0.98 L) (p = 0.019). Water intake was associated negatively with urine specific gravity, urine color, and urine sodium and potassium concentrations (p < 0.01). Applying urine osmolality cut-offs, approximately 60% of participants were euhydrated and 20% hyperhydrated or dehydrated. Most participants were euhydrated, but a substantial number of people (40%) deviated from a normal hydration level.

  20. Equivalency testing of TTC Tergitol 7 agar (ISO 9308-1:2000) with five culture media for the detection of E. coli in water samples in Greece.

    Science.gov (United States)

    Mavridou, A; Smeti, E; Mandilara, G; Mandilara, G; Boufa, P; Vagiona-Arvanitidou, M; Vantarakis, A; Vassilandonopoulou, G; Pappa, O; Roussia, V; Tzouanopoulos, A; Livadara, M; Aisopou, I; Maraka, V; Nikolaou, E; Mandilara, G

    2010-01-01

    In this study ten laboratories in Greece compared the performance of reference method TTC Tergitol 7 Agar (with the additional test of beta-glucuronidase production) with five alternative methods, to detect E. coli in water, in line with European Water Directive recommendations. The samples were prepared by spiking drinking water with sewage effluent following a standard protocol. Chlorinated and non-chlorinated samples were used. The statistical analysis was based on the mean relative difference of confirmed counts and was performed in line with ISO 17994. The results showed that in total, three of the alternative methods (Chromocult Coliform agar, Membrane Lauryl Sulfate agar and Trypton Bilex-glucuronidase medium) were not different from TTC Tergitol 7 agar (TTC Tergitol 7 agar vs Chromocult Coliform agar, 294 samples, mean RD% 5.55; vs MLSA, 302 samples, mean RD% 1; vs TBX, 297 samples, mean RD% -2.78). The other two alternative methods (Membrane Faecal coliform medium and Colilert 18/ Quantitray) gave significantly higher counts than TTC Tergitol 7 agar (TTC Tergitol 7 agar vs MFc, 303 samples, mean RD% 8.81; vs Colilert-18/Quantitray, 76 samples, mean RD% 18.91). In other words, the alternative methods generated performance that was as reliable as, or even better than, the reference method. This study will help laboratories in Greece overcome culture and counting problems deriving from the EU reference method for E. coli counts in water samples.

  1. The Water Reuse project: Sustainable waste water re-use technologies for irrigated land in NIS and southern European states; project overview and results.

    Science.gov (United States)

    van den Elsen, E.; Doerr, S.; Ritsema, C. J.

    2009-04-01

    In irrigated areas in the New Independent States (NIS) and southern European States, inefficient use of conventional water resources occurs through incomplete wetting of soils, which causes accelerated runoff and preferential flow, and also through excessive evaporation associated with unhindered capillary rise. Furthermore, a largely unexploited potential exists to save conventional irrigation water by supplementation with organic-rich waste water, which, if used appropriately, can also lead to improvements to soil physical properties and soil nutrient and organic matter content. This project aims to (a) reduce irrigation water losses by developing, evaluating and promoting techniques that improve the wetting properties of soils, and (b) investigate the use of organic-rich waste water as a non-conventional water resource in irrigation and, in addition, as a tool in improving soil physical properties and soil nutrient and organic matter content. Key activities include (i) identifying, for the NIS and southern European partner countries, the soil type/land use combinations, for which the above approaches are expected to be most effective and their implementation most feasible, using physical and socio-economic research methods, and (ii) examining the water saving potential, physical, biological and chemical effects on soils of the above approaches, and also their impact on performance. Expected outputs include techniques for sustainable improvements in soil wettability management as a novel approach in water saving, detailed evaluation of the prospects and effects of using supplemental organic-rich waste waters in irrigation, an advanced process-based numerical hydrological model, fully adapted to quantify and upscale resulting water savings and nutrient and potential contaminant fluxes for irrigated areas, and identification of suitable areas in the NIS and Mediterranean (in soil, land use, legislative and socio-economic terms) for implementation.

  2. Detection of protozoa in water samples by formalin/ether concentration method.

    Science.gov (United States)

    Lora-Suarez, Fabiana; Rivera, Raul; Triviño-Valencia, Jessica; Gomez-Marin, Jorge E

    2016-09-01

    Methods to detect protozoa in water samples are expensive and laborious. We evaluated the formalin/ether concentration method to detect Giardia sp., Cryptosporidium sp. and Toxoplasma in water. In order to test the properties of the method, we spiked water samples with different amounts of each protozoa (0, 10 and 50 cysts or oocysts) in a volume of 10 L of water. Immunofluorescence assay was used for detection of Giardia and Cryptosporidium. Toxoplasma oocysts were identified by morphology. The mean percent of recovery in 10 repetitions of the entire method, in 10 samples spiked with ten parasites and read by three different observers, were for Cryptosporidium 71.3 ± 12, for Giardia 63 ± 10 and for Toxoplasma 91.6 ± 9 and the relative standard deviation of the method was of 17.5, 17.2 and 9.8, respectively. Intraobserver variation as measured by intraclass correlation coefficient, was fair for Toxoplasma, moderate for Cryptosporidium and almost perfect for Giardia. The method was then applied in 77 samples of raw and drinkable water in three different plant of water treatment. Cryptosporidium was found in 28 of 77 samples (36%) and Giardia in 31 of 77 samples (40%). Theses results identified significant differences in treatment process to reduce the presence of Giardia and Cryptosporidium. In conclusion, the formalin ether method to concentrate protozoa in water is a new alternative for low resources countries, where is urgently need to monitor and follow the presence of theses protozoa in drinkable water. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Cadmium determination in natural waters at the limit imposed by European legislation by isotope dilution and TiO2 solid-phase extraction.

    Science.gov (United States)

    García-Ruiz, Silvia; Petrov, Ivan; Vassileva, Emilia; Quétel, Christophe R

    2011-11-01

    The cadmium content in surface water is regulated by the last European Water Framework Directive to a maximum between 0.08 and 0.25 μg L(-1) depending on the water type and hardness. Direct measurement of cadmium at this low level is not straightforward in real samples, and we hereby propose a validated method capable of addressing cadmium content below μg L(-1) level in natural water. It is based on solid-phase extraction using TiO(2) nanoparticles as solid sorbent (0.05 g packed in mini-columns) to allow the separation and preconcentration of cadmium from the sample, combined to direct isotope dilution and detection by inductively coupled plasma mass spectrometry (ID-ICP-MS). The extraction setup is miniaturised and semi-automated to reduce risks of sample contamination and improve reproducibility. Procedural blanks for the whole measurement process were 5.3 ± 2.8 ng kg(-1) (1 s) for 50 g of ultrapure water preconcentrated ten times. Experimental conditions influencing the separation (including loading pH, sample flow rates, and acid concentration in the eluent) were evaluated. With isotope dilution the Cd recovery rate does not have to be evaluated carefully. Moreover, the mathematical model associated to IDMS is known, and provides transparency for the uncertainty propagation. Our validation protocol was in agreement with guidelines of the ISO/IEC 17025 standard (chapter 5.4.5). Firstly, we assessed the experimental factors influencing the final result. Secondly, we compared the isotope ratios measured after our separation procedure to the reference values obtained with a different protocol for the digested test material IMEP-111 (mineral feed). Thirdly, we analysed the certified reference material BCR-609 (groundwater). Finally, combined uncertainties associated to our results were estimated according to ISO-GUM guidelines (typically, 3-4% k = 2 for a cadmium content of around 100 ng kg(-1)). We applied the developed method to the groundwater and wastewater

  4. UMTRA Project water sampling and analysis plan, Salt Lake City, Utah. Revision 1

    International Nuclear Information System (INIS)

    1995-06-01

    This water sampling and analysis plan describes planned, routine ground water sampling activities at the US Department of Energy Uranium Mill Tailings Remedial Action Project site in Salt Lake City, Utah. This plan identifies and justifies sampling locations, analytical parameters, detection limits, and sampling frequencies for routine monitoring of ground water, sediments, and surface waters at monitoring stations on the site

  5. Determination of organotin compounds in waters by headspace solid phase microextraction gas chromatography triple quadrupole tandem mass spectrometry under the European Water Framework Directive.

    Science.gov (United States)

    Moscoso-Pérez, C; Fernández-González, V; Moreda-Piñeiro, J; López-Mahía, P; Muniategui-Lorenzo, S; Prada-Rodríguez, D

    2015-03-13

    The European Union Water Framework Directive (2013/39/EU) sets very restrictive environmental quality standards for 45 priority substances and other pollutants, including organotin compounds (OTCs). Therefore, it is necessary to develop analytical methods in compliance with the environmental quality standard (EQSs) proposed to protect the aquatic environment and humans. The proposed method (HS-SPME-GC-QqQ-MS/MS) allows the determination of OTCs, i.e. monobutyltin (MBT), dibutyltin (DBT) and TBT in water in the range of few ng L(-1). The method is nearly full automated, sensitive and simple; it involves less reagents, reduces waste, and is less-time consuming than traditional methods for OTCs. As such, the procedure connects with the principles of green analytical chemistry. Additionally, good precision (RSD<20%), a very low method quantification limit (MQL) (0.76 ng L(-1) for TBT by using only 10 mL of sample) and excellent linearity (range MQL-20 ng L(-1)) are achieved. Under these conditions, the very restrictive limits for the environmental quality standards (EQS) fixed by the 2013/39/EU Directive are achieved. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Water Sample Points, Navajo Nation, 2000, USACE

    Data.gov (United States)

    U.S. Environmental Protection Agency — This point shapefile presents the locations and results for water samples collected on the Navajo Nation by the US Army Corps of Engineers (USACE) for the US...

  7. Contamination of Ground Water Samples from Well Installations

    DEFF Research Database (Denmark)

    Grøn, Christian; Madsen, Jørgen Øgaard; Simonsen, Y.

    1996-01-01

    Leaching of a plasticizer, N-butylbenzenesulfonamide, from ground water multilevel sampling installations in nylon has been demonstrated. The leaching resulted in concentrations of DOC and apparent AOX, both comparable with those observed in landfill contaminated ground waters. It is concluded...... that nylon should not be used in studies of contamination with organic compounds....

  8. Throwing velocities, anthropometric characteristics, and efficacy indices of women's European water polo subchampions.

    Science.gov (United States)

    Alcaraz, Pedro E; Abraldes, J Arturo; Ferragut, Carmen; Rodríguez, Nuria; Argudo, Francisco M; Vila, Helena

    2011-11-01

    Water polo is a team sport characterized by a high-intensity, intermittent activity, where technical and tactical aspect are of a great importance. For that reason, the main aim of this study was to define the anthropometrical characteristics, maximum isometric grip strength, training and competition throwing velocities, and the efficacy indices in female high-level water polo players. A second purpose was to examine the differences between the throwing velocities in training vs. European championships in the water polo female national team. Ten elite trained female water polo players participated in this study. Before the competitive phase of their season, the following measures were taken: standard anthropometry, static and dynamic training throwing velocities, and hand-grip dynamometry. In the competitive phase, efficacy indices, average and maximum throwing velocities from all the participants were also determined. Significant differences (p ≤ 0.05) were found between different training situations and different competitive throwing velocities. We concluded that elite female water polo players modify their throwing velocity depending if the throw is performed during training or competitive situation.

  9. Differences in microbial community composition between injection and production water samples of water flooding petroleum reservoirs

    Directory of Open Access Journals (Sweden)

    P. K. Gao

    2015-06-01

    Full Text Available Microbial communities in injected water are expected to have significant influence on those of reservoir strata in long-term water flooding petroleum reservoirs. To investigate the similarities and differences in microbial communities in injected water and reservoir strata, high-throughput sequencing of microbial partial 16S rRNA of the water samples collected from the wellhead and downhole of injection wells, and from production wells in a homogeneous sandstone reservoir and a heterogeneous conglomerate reservoir were performed. The results indicate that a small number of microbial populations are shared between the water samples from the injection and production wells in the sandstone reservoir, whereas a large number of microbial populations are shared in the conglomerate reservoir. The bacterial and archaeal communities in the reservoir strata have high concentrations, which are similar to those in the injected water. However, microbial population abundance exhibited large differences between the water samples from the injection and production wells. The number of shared populations reflects the influence of microbial communities in injected water on those in reservoir strata to some extent, and show strong association with the unique variation of reservoir environments.

  10. Comparison of methods for enumeration of total coliforms and Escherichia coli in water samples in the Netherlands

    NARCIS (Netherlands)

    Schets FM; Nobel PJ; Strating S; Mooijman KA; Engels GB; Brouwer A; Kiwa; PWN; MGB

    2001-01-01

    The new European Drinking Water Directive (December 1998) defines a reference method for estimating the concentration of coliforms and Escherichia coli in drinking water. Laboratories may use other methods, but should demonstrate that results obtained are at least as reliable as those produced with

  11. Sampling trace organic compounds in water: a comparison of a continuous active sampler to continuous passive and discrete sampling methods.

    Science.gov (United States)

    Coes, Alissa L; Paretti, Nicholas V; Foreman, William T; Iverson, Jana L; Alvarez, David A

    2014-03-01

    A continuous active sampling method was compared to continuous passive and discrete sampling methods for the sampling of trace organic compounds (TOCs) in water. Results from each method are compared and contrasted in order to provide information for future investigators to use while selecting appropriate sampling methods for their research. The continuous low-level aquatic monitoring (CLAM) sampler (C.I.Agent® Storm-Water Solutions) is a submersible, low flow-rate sampler, that continuously draws water through solid-phase extraction media. CLAM samplers were deployed at two wastewater-dominated stream field sites in conjunction with the deployment of polar organic chemical integrative samplers (POCIS) and the collection of discrete (grab) water samples. All samples were analyzed for a suite of 69 TOCs. The CLAM and POCIS samples represent time-integrated samples that accumulate the TOCs present in the water over the deployment period (19-23 h for CLAM and 29 days for POCIS); the discrete samples represent only the TOCs present in the water at the time and place of sampling. Non-metric multi-dimensional scaling and cluster analysis were used to examine patterns in both TOC detections and relative concentrations between the three sampling methods. A greater number of TOCs were detected in the CLAM samples than in corresponding discrete and POCIS samples, but TOC concentrations in the CLAM samples were significantly lower than in the discrete and (or) POCIS samples. Thirteen TOCs of varying polarity were detected by all of the three methods. TOC detections and concentrations obtained by the three sampling methods, however, are dependent on multiple factors. This study found that stream discharge, constituent loading, and compound type all affected TOC concentrations detected by each method. In addition, TOC detections and concentrations were affected by the reporting limits, bias, recovery, and performance of each method. Published by Elsevier B.V.

  12. Sampling trace organic compounds in water: a comparison of a continuous active sampler to continuous passive and discrete sampling methods

    Science.gov (United States)

    Coes, Alissa L.; Paretti, Nicholas V.; Foreman, William T.; Iverson, Jana L.; Alvarez, David A.

    2014-01-01

    A continuous active sampling method was compared to continuous passive and discrete sampling methods for the sampling of trace organic compounds (TOCs) in water. Results from each method are compared and contrasted in order to provide information for future investigators to use while selecting appropriate sampling methods for their research. The continuous low-level aquatic monitoring (CLAM) sampler (C.I.Agent® Storm-Water Solutions) is a submersible, low flow-rate sampler, that continuously draws water through solid-phase extraction media. CLAM samplers were deployed at two wastewater-dominated stream field sites in conjunction with the deployment of polar organic chemical integrative samplers (POCIS) and the collection of discrete (grab) water samples. All samples were analyzed for a suite of 69 TOCs. The CLAM and POCIS samples represent time-integrated samples that accumulate the TOCs present in the water over the deployment period (19–23 h for CLAM and 29 days for POCIS); the discrete samples represent only the TOCs present in the water at the time and place of sampling. Non-metric multi-dimensional scaling and cluster analysis were used to examine patterns in both TOC detections and relative concentrations between the three sampling methods. A greater number of TOCs were detected in the CLAM samples than in corresponding discrete and POCIS samples, but TOC concentrations in the CLAM samples were significantly lower than in the discrete and (or) POCIS samples. Thirteen TOCs of varying polarity were detected by all of the three methods. TOC detections and concentrations obtained by the three sampling methods, however, are dependent on multiple factors. This study found that stream discharge, constituent loading, and compound type all affected TOC concentrations detected by each method. In addition, TOC detections and concentrations were affected by the reporting limits, bias, recovery, and performance of each method.

  13. The European Pressurized Water Reactor (EPR). State of the art after the preliminary design phase

    International Nuclear Information System (INIS)

    Bouteille, F.; Schneider, D.

    2002-01-01

    The European Pressurized Water Reactor (EPR) is an evolutionary development of the pressurized water reactor product lines built by Framatome and Siemens in France and Germany. Under the technical leadership of both nuclear power plant suppliers (now merged in Framatome ANP, a joint venture of AREVA and Siemens) the future-oriented plant concepts was developed in close cooperation with German and French utilities and in compliance with the European Utility Requirements. The EPR has safety features with which even extremely improbable, beyond design-basis events can be controlled and their effects can be limited to such an extent that no emergency response actions need be taken outside of the immediate plant site. This also means that safety systems prevent containment failure even in the improbable case of a core melt. This was confirmed by the French and German reactor safety authorities. The selected high thermal output also insures the economic viability of the innovative reactor concept, so that the power generation costs which can be achieved with the EPR will be absolutely competitive with those of fossil energy carriers. Framatome ANP has thus developed a pressurized water reactor ready for offer at the right time, which can completely fulfill the most rigorous requirements in terms of nuclear safety and economy. (Author)

  14. Radiation dose-dependent risk on individuals due to ingestion of uranium and radon concentration in drinking water samples of four districts of Haryana, India

    Science.gov (United States)

    Panghal, Amanjeet; Kumar, Ajay; Kumar, Suneel; Singh, Joga; Sharma, Sumit; Singh, Parminder; Mehra, Rohit; Bajwa, B. S.

    2017-06-01

    Uranium gets into drinking water when the minerals containing uranium are dissolved in groundwater. Uranium and radon concentrations have been measured in drinking water samples from different water sources such as hand pumps, tube wells and bore wells at different depths from various locations of four districts (Jind, Rohtak, Panipat and Sonipat) of Haryana, India, using the LED flourimetry technique and RAD7, electronic silicon solid state detector. The uranium (238U) and radon (222Rn) concentrations in water samples have been found to vary from 1.07 to 40.25 µg L-1 with an average of 17.91 µg L-1 and 16.06 ± 0.97 to 57.35 ± 1.28 Bq L-1 with an average of 32.98 ± 2.45 Bq L-1, respectively. The observed value of radon concentration in 43 samples exceeded the recommended limits of 11 Bq L-1 (USEPA) and all the values are within the European Commission recommended limit of 100 Bq L-1. The average value of uranium concentration is observed to be within the safe limit recommended by World Health Organization (WHO) and Atomic Energy Regulatory Board. The annual effective dose has also been measured in all the water samples and is found to be below the prescribed dose limit of 100 µSv y-1 recommended by WHO. Risk assessment of uranium in water is also calculated using life time cancer risk, life time average daily dose and hazard quotient. The high uranium concentration observed in certain areas is due to interaction of ground water with the soil formation of this region and the local subsurface geology of the region.

  15. Concentration of ions in selected bottled water samples sold in Malaysia

    Science.gov (United States)

    Aris, Ahmad Zaharin; Kam, Ryan Chuan Yang; Lim, Ai Phing; Praveena, Sarva Mangala

    2013-03-01

    Many consumers around the world, including Malaysians, have turned to bottled water as their main source of drinking water. The aim of this study is to determine the physical and chemical properties of bottled water samples sold in Selangor, Malaysia. A total of 20 bottled water brands consisting of `natural mineral (NM)' and `packaged drinking (PD)' types were randomly collected and analyzed for their physical-chemical characteristics: hydrogen ion concentration (pH), electrical conductivity (EC) and total dissolved solids (TDS), selected major ions: calcium (Ca), potassium (K), magnesium (Mg) and sodium (Na), and minor trace constituents: copper (Cu) and zinc (Zn) to ascertain their suitability for human consumption. The results obtained were compared with guideline values recommended by World Health Organization (WHO) and Malaysian Ministry of Health (MMOH), respectively. It was found that all bottled water samples were in accordance with the guidelines set by WHO and MMOH except for one sample (D3) which was below the pH limit of 6.5. Both NM and PD bottled water were dominated by Na + K > Ca > Mg. Low values for EC and TDS in the bottled water samples showed that water was deficient in essential elements, likely an indication that these were removed by water treatment. Minerals like major ions were present in very low concentrations which could pose a risk to individuals who consume this water on a regular basis. Generally, the overall quality of the supplied bottled water was in accordance to standards and guidelines set by WHO and MMOH and safe for consumption.

  16. Bacterial contamination of water samples in Gabon, 2013

    Directory of Open Access Journals (Sweden)

    Jonas Ehrhardt

    2017-10-01

    Full Text Available Contamination of water is a major burden in the public health setting of developing countries. We therefore assessed the quality of water samples in Gabon in 2013. The main findings were a contamination rate with coliforms of 13.5% and the detection of a possible environmental reservoir for extended spectrum beta-lactamase-producing bacteria.

  17. Portable field water sample filtration unit

    International Nuclear Information System (INIS)

    Hebert, A.J.; Young, G.G.

    1977-01-01

    A lightweight back-packable field-tested filtration unit is described. The unit is easily cleaned without cross contamination at the part-per-billion level and allows rapid filtration of boiling hot and sometimes muddy water. The filtration results in samples that are free of bacteria and particulates and which resist algae growth even after storage for months. 3 figures

  18. Estimating an appropriate sampling frequency for monitoring ground water well contamination

    International Nuclear Information System (INIS)

    Tuckfield, R.C.

    1994-01-01

    Nearly 1,500 ground water wells at the Savannah River Site (SRS) are sampled quarterly to monitor contamination by radionuclides and other hazardous constituents from nearby waste sites. Some 10,000 water samples were collected in 1993 at a laboratory analysis cost of $10,000,000. No widely accepted statistical method has been developed, to date, for estimating a technically defensible ground water sampling frequency consistent and compliant with federal regulations. Such a method is presented here based on the concept of statistical independence among successively measured contaminant concentrations in time

  19. Polymeric ionic liquid-based portable tip microextraction device for on-site sample preparation of water samples.

    Science.gov (United States)

    Chen, Lei; Pei, Junxian; Huang, Xiaojia; Lu, Min

    2018-06-05

    On-site sample preparation is highly desired because it avoids the transportation of large-volume samples and ensures the accuracy of the analytical results. In this work, a portable prototype of tip microextraction device (TMD) was designed and developed for on-site sample pretreatment. The assembly procedure of TMD is quite simple. Firstly, polymeric ionic liquid (PIL)-based adsorbent was in-situ prepared in a pipette tip. After that, the tip was connected with a syringe which was driven by a bidirectional motor. The flow rates in adsorption and desorption steps were controlled accurately by the motor. To evaluate the practicability of the developed device, the TMD was used to on-site sample preparation of waters and combined with high-performance liquid chromatography with diode array detection to measure trace estrogens in water samples. Under the most favorable conditions, the limits of detection (LODs, S/N = 3) for the target analytes were in the range of 4.9-22 ng/L, with good coefficients of determination. Confirmatory study well evidences that the extraction performance of TMD is comparable to that of the traditional laboratory solid-phase extraction process, but the proposed TMD is more simple and convenient. At the same time, the TMD avoids complicated sampling and transferring steps of large-volume water samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Water-quality assessment of south-central Texas : comparison of water quality in surface-water samples collected manually and by automated samplers

    Science.gov (United States)

    Ging, Patricia B.

    1999-01-01

    Surface-water sampling protocols of the U.S. Geological Survey National Water-Quality Assessment (NAWQA) Program specify samples for most properties and constituents to be collected manually in equal-width increments across a stream channel and composited for analysis. Single-point sampling with an automated sampler (autosampler) during storms was proposed in the upper part of the South-Central Texas NAWQA study unit, raising the question of whether property and constituent concentrations from automatically collected samples differ significantly from those in samples collected manually. Statistical (Wilcoxon signed-rank test) analyses of 3 to 16 paired concentrations for each of 26 properties and constituents from water samples collected using both methods at eight sites in the upper part of the study unit indicated that there were no significant differences in concentrations for dissolved constituents, other than calcium and organic carbon.

  1. A device for fresh water sampling before radioactive measurements

    International Nuclear Information System (INIS)

    Maubert, Henri; Picat, Philippe.

    1982-06-01

    On account of the many field operations carried out by the laboratory, a water sampling device has been developed. This portable autonomous device performs in situ water filtration and concentration on ion exchange resins and activated carbon columns. The device is described and the trapping performance for 8 radionuclides is given. A comparison is made with the so-called evaporation method. The effects of the treatment of the filtrating elements on the radioactive results are studied. This sampling method is very sensitive [fr

  2. Cadmium determination in natural waters at the limit imposed by European legislation by isotope dilution and TiO{sub 2} solid-phase extraction

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Ruiz, Silvia; Quetel, Christophe R. [Institute for Reference Materials and Measurements, Joint Research Centre - European Commission, Geel (Belgium); Petrov, Ivan [Institute for Reference Materials and Measurements, Joint Research Centre - European Commission, Geel (Belgium); Universite Libre de Bruxelles, Department of Earth and Environmental Sciences, Brussels (Belgium); Vassileva, Emilia [Institute for Reference Materials and Measurements, Joint Research Centre - European Commission, Geel (Belgium); IAEA-Marine Environment Laboratories, Monaco (Monaco)

    2011-11-15

    The cadmium content in surface water is regulated by the last European Water Framework Directive to a maximum between 0.08 and 0.25 {mu}g L{sup -1} depending on the water type and hardness. Direct measurement of cadmium at this low level is not straightforward in real samples, and we hereby propose a validated method capable of addressing cadmium content below {mu}g L{sup -1} level in natural water. It is based on solid-phase extraction using TiO{sub 2} nanoparticles as solid sorbent (0.05 g packed in mini-columns) to allow the separation and preconcentration of cadmium from the sample, combined to direct isotope dilution and detection by inductively coupled plasma mass spectrometry (ID-ICP-MS). The extraction setup is miniaturised and semi-automated to reduce risks of sample contamination and improve reproducibility. Procedural blanks for the whole measurement process were 5.3 {+-} 2.8 ng kg{sup -1} (1 s) for 50 g of ultrapure water preconcentrated ten times. Experimental conditions influencing the separation (including loading pH, sample flow rates, and acid concentration in the eluent) were evaluated. With isotope dilution the Cd recovery rate does not have to be evaluated carefully. Moreover, the mathematical model associated to IDMS is known, and provides transparency for the uncertainty propagation. Our validation protocol was in agreement with guidelines of the ISO/IEC 17025 standard (chapter 5.4.5). Firstly, we assessed the experimental factors influencing the final result. Secondly, we compared the isotope ratios measured after our separation procedure to the reference values obtained with a different protocol for the digested test material IMEP-111 (mineral feed). Thirdly, we analysed the certified reference material BCR-609 (groundwater). Finally, combined uncertainties associated to our results were estimated according to ISO-GUM guidelines (typically, 3-4% k = 2 for a cadmium content of around 100 ng kg{sup -1}). We applied the developed method to the

  3. Qualilty, isotopes, and radiochemistry of water sampled from the Upper Moenkopi Village water-supply wells, Coconino County, Arizona

    Science.gov (United States)

    Carruth, Rob; Beisner, Kimberly; Smith, Greg

    2013-01-01

    The Hopi Tribe Water Resources Program has granted contracts for studies to evaluate water supply conditions for the Moenkopi villages in Coconino County, Arizona. The Moenkopi villages include Upper Moenkopi Village and the village of Lower Moencopi, both on the Hopi Indian Reservation south of the Navajo community of Tuba City. These investigations have determined that water supplies are limited and vulnerable to several potential sources of contamination, including the Tuba City Landfill and a former uranium processing facility known as the Rare Metals Mill. Studies are ongoing to determine if uranium and other metals in groundwater beneath the landfill are greater than regional groundwater concentrations. The source of water supply for the Upper Moenkopi Village is three public-supply wells. The wells are referred to as MSW-1, MSW-2, and MSW-3 and all three wells obtain water from the regionally extensive N aquifer. The N aquifer is the principal aquifer in this region of northern Arizona and consists of thick beds of sandstone between less permeable layers of siltstone and mudstone. The relatively fine-grained character of the N aquifer inhibits rapid movement of water and large yields to wells. In recent years, water levels have declined in the three public-supply wells, causing concern that the current water supply will not be able to accommodate peak demand and allow for residential and economic growth. Analyses of major ions, nutrients, selected trace metals, stable and radioactive isotopes, and radiochemistry were performed on the groundwater samples from the three public-supply wells to describe general water-quality conditions and groundwater ages in and immediately surrounding the Upper Moenkopi Village area. None of the water samples collected from the public-supply wells exceeded the U.S. Environmental Protection Agency primary drinking water standards. The ratios of the major dissolved ions from the samples collected from MSW-1 and MSW-2 indicate

  4. 8. European sewage and refuse symposium. Documentation

    International Nuclear Information System (INIS)

    1990-01-01

    The subject of the 8. European Sewage and Refuse Symposium is covered under the following headings: collection and control in sewers, industrial waste water management, pretreatment, combined treatment, special cases, industrial waste water sludges disposal and the European waste business. (orig./BBR)

  5. Determining the impacts of trawling on benthic function in European waters : a biological traits approach

    DEFF Research Database (Denmark)

    Bolam, Stefan; Kenny, Andrew; Garcia, Clement

    characteristics, have allowed us to better understand the interactions between the benthic fauna and their environment at a functional level. We present the initial findings of work conducted under the auspices of the EU-funded project ‘BENTHIS’ which aims to improve our understanding of the impacts of trawling...... on benthic ecosystem functioning over much larger spatial scales than previously undertaken. Biological traits information from 887 stations across European waters (Norwegian, UK, Belgian, Dutch, Danish waters, the Mediterranean and Black Sea) were analysed to: i) quantify the relationships between infaunal...

  6. Sea-water/groundwater interactions along a small catchment of the European Atlantic coast

    International Nuclear Information System (INIS)

    Einsiedl, Florian

    2012-01-01

    The geochemistry and isotopic composition of a karstic coastal aquifer in western Ireland has shed light on the effect of sea-water/groundwater interactions on the water quality of Ireland’s Atlantic coastal zone. The use of stable isotope data from the IAEA precipitation station in Valentia, located in SW Ireland has facilitated the characterization of groundwater recharge conditions in the western part of Ireland and suggests that groundwater is mostly replenished by the isotopically light winter precipitation. The dissolved SO 4 2- in the karstic groundwater that was collected during baseflow conditions with δ 34 S values between 4.6‰ and 18‰ may be composed of S stemming from three principal sources: SO 4 2- derived from precipitation which is composed of both sea-spray S (δ 34 S: 20‰) and an isotopically light anthropogenic source (δ 34 S: 1–5‰), SO 4 2- stemming from animal slurries (δ 34 S: ∼5‰), and intruding sea-water SO 4 2- (δ 34 S: 20.2‰). The isotopic composition of δ 18 O in dissolved groundwater SO 4 2- collected during baseflow conditions is interpreted as reflecting sea-water intrusion to the karstic coastal groundwater system. The highest δ 18 O values in dissolved groundwater SO 4 2- were in samples collected near the coast (4.8 ± 0.4‰) and the lowest (2 ± 0.5‰) were collected further inland. The δ 15 N and δ 18 O values of groundwater NO 3 - were between 3.4‰ and 11.4‰ and approximately 7.7‰, respectively, and reflect geochemical conditions in the aquifer that do not promote attenuation of NO 3 - through denitrification. As a result N loading to Kinvara Bay that is controlled by submarine groundwater discharge (SGD) was calculated as 5 tons/day on average compared to an estimated N-input that derives from precipitation of approximately 2.5 tons/a. SGD into the bay may result in near coastal sea-water quality changes. These results represent one of the first studies addressing the effect of groundwater

  7. UMTRA water sampling and analysis plan, Tuba City, Arizona

    International Nuclear Information System (INIS)

    1993-09-01

    The purpose of this document is to provide background, guidance, and justification for fiscal year (FY) 1994 water sampling activities for the uranium mil tailings site at Tuba City, Arizona. This sampling and analysis plan will form the basis for groundwater sampling and analysis work orders to be implemented in FY94

  8. Condensed tannins in extracts from European medicinal plants and herbal products.

    Science.gov (United States)

    Ropiak, Honorata M; Ramsay, Aina; Mueller-Harvey, Irene

    2016-03-20

    Medicinal plant materials are not usually analysed for condensed tannins (CT). Thirty commercially available European medicinal plants and herbal products were screened for CT and fourteen CT samples were analysed in detail. This is also the first comprehensive CT analysis of pine buds, walnut leaves, heather flowers and great water dock roots. Acetone/water extracts contained between 3.2 and 25.9 g CT/100g of extract, had CT with mean degrees of polymerisation of 2.9 to 13.3, procyanidin/prodelphinidin ratios of 1.6/98.4 to 100/0 and cis/trans flavan-3-ol ratios of 17.7/82.3 to 97.3/2.7. The majority of samples contained procyanidins, four contained A-type linkages (blackthorn flowers, heather flowers, bilberry leaves and cowberry leaves) and one sample also had galloylated procyanidins (great water dock roots). Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Prospects for plutonium recycling in light-water reactors in the European Communities

    International Nuclear Information System (INIS)

    Haijtink, B.

    1977-01-01

    On the basis of a forecast on nuclear power installation programmes and spent nuclear fuel reprocessing capacities in the European Community, an assessment has been made of the developmnt of the plutonium handling industry up to the year 1990. Data on plutonium recovered in the reprocessing plants, requirements for fuelling the fast-breeder reactors and the remaining stockpile have been evaluated. A possible strategy for recycling the plutonium surplus in light-water reactors has been developed and its effects as regards saving on requirements for natural uranium and enrichment services have been estimated

  10. Solvent-assisted dispersive solid-phase extraction: A sample preparation method for trace detection of diazinon in urine and environmental water samples.

    Science.gov (United States)

    Aladaghlo, Zolfaghar; Fakhari, Alireza; Behbahani, Mohammad

    2016-09-02

    In this research, a sample preparation method termed solvent-assisted dispersive solid-phase extraction (SA-DSPE) was applied. The used sample preparation method was based on the dispersion of the sorbent into the aqueous sample to maximize the interaction surface. In this approach, the dispersion of the sorbent at a very low milligram level was received by inserting a solution of the sorbent and disperser solvent into the aqueous sample. The cloudy solution created from the dispersion of the sorbent in the bulk aqueous sample. After pre-concentration of the diazinon, the cloudy solution was centrifuged and diazinon in the sediment phase dissolved in ethanol and determined by gas chromatography-flame ionization detector. Under the optimized conditions (pH of solution=7.0, Sorbent: benzophenone, 2%, Disperser solvent: ethanol, 500μL, Centrifuge: centrifuged at 4000rpm for 3min), the method detection limit for diazinon was 0.2, 0.3, 0.3 and 0.3μgL(-1) for distilled water, lake water, waste water and urine sample, respectively. Furthermore, the pre-concentration factor was 363.8, 356.1, 360.7 and 353.38 in distilled water, waste water, lake water and urine sample, respectively. SA-DSPE was successfully used for trace monitoring of diazinon in urine, lake and waste water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  11. Preconcentration of uranium in water samples using dispersive ...

    African Journals Online (AJOL)

    Preconcentration of uranium in water samples using dispersive liquid-liquid micro- extraction coupled with solid-phase extraction and determination with inductively coupled plasma-optical emission spectrometry.

  12. Uranium and thorium determination in water samples taken along River Kura

    International Nuclear Information System (INIS)

    Ahmadov, M.M.; Ibadov, N.A.; Safarova, K.S.; Humbatov, F.Y.; Suleymanov, B.A.

    2014-01-01

    Full text : In the present investigation, uranium and thorium concentration in rivers water of Azerbaijan has been measured using inductively coupled plasma mass spectrometry. The Agilent 7700x series ICP-MS applied for analysis of water samples. This method is based on direct introduction of samples, without any chemical pre-treatment, into an inductively coupled plasma plasma mass spectrometer. Uranium and thorium was determined at the mass mass numbers of 238 and 232 respectively using Bi-209 as internal standard. The main purpose of the study is to measure the level of uranium and thorium in water samples taken along river Kura

  13. Further European initiatives and regulations concerning radiation protection: drinking water guideline, maximum permissible contamination in food products and feeding stuff

    International Nuclear Information System (INIS)

    Mundigl, Stefan

    2013-01-01

    The radiation protection community has observed intensively the development of basic safety standards concerning protection against hazards of ionizing radiation. The new core part of the European radiation protection legislation is complemented by several specialized regulations relevant for radiation protection. Besides the existing regulations in the field of emergency protection the European Commission initiated a drinking water guideline that will be published in the near future. Furthermore the European commission approved a revised regulation concerning the maximum permissible contamination limits for food products and feeding stuff in case of a future nuclear accident. Together with the new radiation protection basic standards a new complete, coherent and modernized European regulation package will be accomplished.

  14. Mutagenicity of drinking water sampled from the Yangtze River and Hanshui River (Wuhan section) and correlations with water quality parameters.

    Science.gov (United States)

    Lv, Xuemin; Lu, Yi; Yang, Xiaoming; Dong, Xiaorong; Ma, Kunpeng; Xiao, Sanhua; Wang, Yazhou; Tang, Fei

    2015-03-31

    A total of 54 water samples were collected during three different hydrologic periods (level period, wet period, and dry period) from Plant A and Plant B (a source for Yangtze River and Hanshui River water, respectively), and several water parameters, such as chemical oxygen demand (COD), turbidity, and total organic carbon (TOC), were simultaneously analyzed. The mutagenicity of the water samples was evaluated using the Ames test with Salmonella typhimurium strains TA98 and TA100. According to the results, the organic compounds in the water were largely frame-shift mutagens, as positive results were found for most of the tests using TA98. All of the finished water samples exhibited stronger mutagenicity than the relative raw and distribution water samples, with water samples collected from Plant B presenting stronger mutagenic strength than those from Plant A. The finished water samples from Plant A displayed a seasonal-dependent variation. Water parameters including COD (r = 0.599, P = 0.009), TOC (r = 0.681, P = 0.02), UV254 (r = 0.711, P = 0.001), and total nitrogen (r = 0.570, P = 0.014) exhibited good correlations with mutagenicity (TA98), at 2.0 L/plate, which bolsters the argument of the importance of using mutagenicity as a new parameter to assess the quality of drinking water.

  15. Classification and authentication of unknown water samples using machine learning algorithms.

    Science.gov (United States)

    Kundu, Palash K; Panchariya, P C; Kundu, Madhusree

    2011-07-01

    This paper proposes the development of water sample classification and authentication, in real life which is based on machine learning algorithms. The proposed techniques used experimental measurements from a pulse voltametry method which is based on an electronic tongue (E-tongue) instrumentation system with silver and platinum electrodes. E-tongue include arrays of solid state ion sensors, transducers even of different types, data collectors and data analysis tools, all oriented to the classification of liquid samples and authentication of unknown liquid samples. The time series signal and the corresponding raw data represent the measurement from a multi-sensor system. The E-tongue system, implemented in a laboratory environment for 6 numbers of different ISI (Bureau of Indian standard) certified water samples (Aquafina, Bisleri, Kingfisher, Oasis, Dolphin, and McDowell) was the data source for developing two types of machine learning algorithms like classification and regression. A water data set consisting of 6 numbers of sample classes containing 4402 numbers of features were considered. A PCA (principal component analysis) based classification and authentication tool was developed in this study as the machine learning component of the E-tongue system. A proposed partial least squares (PLS) based classifier, which was dedicated as well; to authenticate a specific category of water sample evolved out as an integral part of the E-tongue instrumentation system. The developed PCA and PLS based E-tongue system emancipated an overall encouraging authentication percentage accuracy with their excellent performances for the aforesaid categories of water samples. Copyright © 2011 ISA. Published by Elsevier Ltd. All rights reserved.

  16. Improved prediction of vegetation composition in NW European softwater lakes by combining location, water and sediment chemistry

    DEFF Research Database (Denmark)

    Pulido Pérez, Cristina; Jensen, Kaj Sand; Lucassen, Esther C.H.E.T.

    2012-01-01

    Isoetids, as indicators of near-pristine softwater lakes, have a high priority in national and international (European Water Directive Framework) assessments of ecological lake quality. Our main goal was to identify the most important environmental factors that influence the composition of plant...

  17. Variability in the Water Footprint of Arable Crop Production across European Regions

    Directory of Open Access Journals (Sweden)

    Anne Gobin

    2017-02-01

    Full Text Available Crop growth and yield are affected by water use during the season: the green water footprint (WF accounts for rain water, the blue WF for irrigation and the grey WF for diluting agri-chemicals. We calibrated crop yield for FAO’s water balance model “Aquacrop” at field level. We collected weather, soil and crop inputs for 45 locations for the period 1992–2012. Calibrated model runs were conducted for wheat, barley, grain maize, oilseed rape, potato and sugar beet. The WF of cereals could be up to 20 times larger than the WF of tuber and root crops; the largest share was attributed to the green WF. The green and blue WF compared favourably with global benchmark values (R2 = 0.64–0.80; d = 0.91–0.95. The variability in the WF of arable crops across different regions in Europe is mainly due to variability in crop yield ( c v ¯ = 45% and to a lesser extent to variability in crop water use ( c v ¯ = 21%. The WF variability between countries ( c v ¯ = 14% is lower than the variability between seasons ( c v ¯ = 22% and between crops ( c v ¯ = 46%. Though modelled yields increased up to 50% under sprinkler irrigation, the water footprint still increased between 1% and 25%. Confronted with drainage and runoff, the grey WF tended to overestimate the contribution of nitrogen to the surface and groundwater. The results showed that the water footprint provides a measurable indicator that may support European water governance.

  18. An Optimized Method for Quantification of Pathogenic Leptospira in Environmental Water Samples.

    Science.gov (United States)

    Riediger, Irina N; Hoffmaster, Alex R; Casanovas-Massana, Arnau; Biondo, Alexander W; Ko, Albert I; Stoddard, Robyn A

    2016-01-01

    Leptospirosis is a zoonotic disease usually acquired by contact with water contaminated with urine of infected animals. However, few molecular methods have been used to monitor or quantify pathogenic Leptospira in environmental water samples. Here we optimized a DNA extraction method for the quantification of leptospires using a previously described Taqman-based qPCR method targeting lipL32, a gene unique to and highly conserved in pathogenic Leptospira. QIAamp DNA mini, MO BIO PowerWater DNA and PowerSoil DNA Isolation kits were evaluated to extract DNA from sewage, pond, river and ultrapure water samples spiked with leptospires. Performance of each kit varied with sample type. Sample processing methods were further evaluated and optimized using the PowerSoil DNA kit due to its performance on turbid water samples and reproducibility. Centrifugation speeds, water volumes and use of Escherichia coli as a carrier were compared to improve DNA recovery. All matrices showed a strong linearity in a range of concentrations from 106 to 10° leptospires/mL and lower limits of detection ranging from Leptospira in environmental waters (river, pond and sewage) which consists of the concentration of 40 mL samples by centrifugation at 15,000×g for 20 minutes at 4°C, followed by DNA extraction with the PowerSoil DNA Isolation kit. Although the method described herein needs to be validated in environmental studies, it potentially provides the opportunity for effective, timely and sensitive assessment of environmental leptospiral burden.

  19. The Climaware project: Impacts of climate change on water resources management - regional strategies and European view

    Science.gov (United States)

    Thirel, Guillaume; D'Agostino, Daniela; Démerliac, Stéphane; Dorchies, David; Flörke, Martina; Jay-Allemand, Maxime; Jost, Claudine; Kehr, Katrin; Perrin, Charles; Scardigno, Alessandra; Schneider, Christof; Theobald, Stephan; Träbing, Klaus

    2014-05-01

    Climate projections produced with CMIP5 and applied by the Intergovernmental Panel on Climate Change (IPCC) in its fifth assessment report indicate that changes in precipitation and temperature are expected to occur throughout Europe in the 21th century, with a likely decrease of water availability in many regions. Besides, water demand is also expected to increase, in link with these expected climate modifications, but also due to socio-economic and demographic changes. In this respect, the use of future freshwater resources may not be sustainable from the current water management perspective. Therefore adaptation strategies will most likely be needed to cope with these evolutions. In this context, the main objective of the ClimAware project (2010-2013 - www.uni-kassel.de/fb14/wasserbau/CLIMAWARE/, a project implemented within the IWRM-NET Funding Initiative) was to analyse the impacts of climate change (CC) on freshwater resources at the continental and regional scales and to identify efficient adaptation strategies to improve water management for various socio-economic sectors. This should contribute to a more effective implementation of the Water Framework Directive (WFD) and its instruments (river basin management plans, programmes of measures). The project developed integrated measures for improved freshwater management under CC constraints. More specifically, the objectives of the ClimAware project were to: • elaborate quantitative projections of changes in river flows and consequences such as flood frequency, drought occurrence and sectorial water uses. • analyse the effect of CC on the hydromorphological reference conditions of rivers and therefore the definition of "good status". • define management rules/strategies concerning dam management and irrigation practices on different time perspectives. • investigate uncertainties in climate model - scenario combinations. The research approach considered both European and regional perspectives, to get

  20. UMTRA Project water sampling and analysis plan, Grand Junction, Colorado. Revision 1, Version 6

    International Nuclear Information System (INIS)

    1995-09-01

    This water sampling and analysis plan describes the planned, routine ground water sampling activities at the Grand Junction US DOE Uranium Mill Tailings Remedial Action (UMTRA) Project site (GRJ-01) in Grand Junction, Colorado, and at the Cheney Disposal Site (GRJ-03) near Grand Junction. The plan identifies and justifies the sampling locations, analytical parameters, detection limits, and sampling frequencies for the routine monitoring stations at the sites. Regulatory basis is in the US EPA regulations in 40 CFR Part 192 (1994) and EPA ground water quality standards of 1995 (60 FR 2854). This plan summarizes results of past water sampling activities, details water sampling activities planned for the next 2 years, and projects sampling activities for the next 5 years

  1. Supplement to the UMTRA project water sampling and analysis plan, Slick Rock, Colorado

    International Nuclear Information System (INIS)

    1995-09-01

    The water sampling and analysis plan (WSAP) provides the regulatory and technical basis for ground water and surface water sampling at the Uranium Mill Tailings Remedial Action (UMTRA) Project Union Carbide (UC) and North Continent (NC) processing sites and the Burro Canyon disposal site near Slick Rock, Colorado. The initial WSAP was finalized in August 1994 and will be completely revised in accordance with the WSAP guidance document (DOE, 1995) in late 1996. This version supplements the initial WSAP, reflects only minor changes in sampling that occurred in 1995, covers sampling scheduled for early 1996, and provides a preliminary projection of the next 5 years of sampling and monitoring activities. Once surface remedial action is completed at the former processing sites, additional and more detailed hydrogeologic characterization may be needed to develop the Ground Water Program conceptual ground water model and proposed compliance strategy. In addition, background ground water quality needs to be clearly defined to ensure that the baseline risk assessment accurately estimated risks from the contaminants of potential concern in contaminated ground water at the UC and NC sites

  2. Water and chemical input via hydrometeors in central European mountains with Szrenica as an example

    Science.gov (United States)

    Błaś, M.; Sobik, M.; Polkowska, Ż.; Cichała-Kamrowska, K.

    2010-07-01

    of precipitation (880 µMoles•l 1), with nitrates, ammonia and sulphates as major ions (27%, 26% and 11% respectively). It is due to the more polluted nature of the boundary layer than the free atmosphere, as well as fog water originating in low-level air. That is also the reason why chemical composition of low-level clouds forms an appriopriate indicator of the local and regional scale anthropogenic pollution and for larger scale comparisons of chemical components in cloudy environments. Summarizing, direct pollutant deposition via cloud droplets to vegetation is larger than via precipitation because of much higher pollutant concentration of the former. Dew and hoarfrost provide water quantities much lower to fog or rain, but is a modest supplementary source of water (approximately 0,8% when compare with precipitation). They appear especially during the anticyclonic type of weather with no wind and clear night skies, rare at summit position. TIC for dew and hoarfrost samples was a bit higher in comparison with precipitation (346 µMoles•l-1), but chemical composition quite different to others hydrometeors (chloride - 20%, sodium - 19% and calcium - 18%). It might be explained by air subsidence from the upper part of atmosphere, typical for the mountain summits in anticyclonic type of weather. Stable thermal stratification limits vertical air pollutant transport, especially of anthropogenic origin, and the thickness of the atmospheric mixing layer is visibly lessened. Hence, maritime aerosol is much more important in such circumstances. Both climate and landscape in Poland are similar to major part of central and western Europe so you can expect that relationship between different components of water flux and pollutant deposition observed at the Mt. Szrenica are applicable also to other European countries where similar natural conditions are found.

  3. Major inorganic elements in tap water samples in Peninsular Malaysia.

    Science.gov (United States)

    Azrina, A; Khoo, H E; Idris, M A; Amin, I; Razman, M R

    2011-08-01

    Quality drinking water should be free from harmful levels of impurities such as heavy metals and other inorganic elements. Samples of tap water collected from 24 locations in Peninsular Malaysia were determined for inorganic element content. Minerals and heavy metals were analysed by spectroscopy methods, while non-metal elements were analysed using test kits. Minerals and heavy metals determined were sodium, magnesium, potassium, calcium, chromium, manganese, iron, nickel, copper, zinc, arsenic, cadmium and lead while the non-metal elements were fluoride, chloride, nitrate and sulphate. Most of the inorganic elements found in the samples were below the maximum permitted levels recommended by inter-national drinking water standard limits, except for iron and manganese. Iron concentration of tap water from one of the locations was higher than the standard limit. In general, tap water from different parts of Peninsular Malaysia had low concentrations of heavy metals and inorganic elements.

  4. Water quality monitoring: A comparative case study of municipal and Curtin Sarawak's lake samples

    Science.gov (United States)

    Anand Kumar, A.; Jaison, J.; Prabakaran, K.; Nagarajan, R.; Chan, Y. S.

    2016-03-01

    In this study, particle size distribution and zeta potential of the suspended particles in municipal water and lake surface water of Curtin Sarawak's lake were compared and the samples were analysed using dynamic light scattering method. High concentration of suspended particles affects the water quality as well as suppresses the aquatic photosynthetic systems. A new approach has been carried out in the current work to determine the particle size distribution and zeta potential of the suspended particles present in the water samples. The results for the lake samples showed that the particle size ranges from 180nm to 1345nm and the zeta potential values ranges from -8.58 mV to -26.1 mV. High zeta potential value was observed in the surface water samples of Curtin Sarawak's lake compared to the municipal water. The zeta potential values represent that the suspended particles are stable and chances of agglomeration is lower in lake water samples. Moreover, the effects of physico-chemical parameters on zeta potential of the water samples were also discussed.

  5. Exploring the potential impact of implementing carbon capture technologies in fossil fuel power plants on regional European water stress index levels

    NARCIS (Netherlands)

    Schakel, W.B.; Pfister, Stephan; Ramirez, C.A.

    Equipping power plants with carbon capture technology can affect cooling demand and water use. This study has explored the potential impact of large scale deployment of power plants with carbon capture technologies on future regional water stress in Europe. A database including 458 of European

  6. Spatially based methods to assess the ecological status of riverine fish assemblages in European ecoregions

    NARCIS (Netherlands)

    Schmutz, S.; Beier, U.; Bohmer, J.; Leeuw, de J.J.

    2007-01-01

    The objective was to develop spatially based (type-specific) methods to assess the ecological status of European rivers according to the EU Water Framework Directive. Some 15 000 samples from about 8000 sites were pre-classified within a five-tiered classification system based on hydromorphological

  7. Monitoring and sampling perched ground water in a basaltic terrain

    International Nuclear Information System (INIS)

    Hubbell, J.M.

    1990-01-01

    Perched ground water zones are often overlooked in monitoring plans, but they can provide significant information on water and contaminant movement. This paper presents information about perched ground water obtained from drilling and monitoring at a hazardous and radioactive waste disposal site at the Idaho National Engineering Laboratory. Six of forty-five wells drilled at the Radioactive Waste Management Complex have detected perched water in basalts above sedimentary interbeds. Perched water has been detected at depths of 90 and 210 ft below land surface, approximately 370 ft above the regional water table. Eighteen years of water level measurements from one well at a depth of 210 ft indicate a consistent source of water. Water level data indicate a seasonal fluctuation. The maximum water level in this well varies within a 0.5 ft interval, suggesting the water level reaches equilibrium with the inflow to the well at this height. Volatile organic constituents have been detected in concentrations from 1.2 to 1.4 mg/L of carbon tetrachloride. Eight other volatile organics have been detected. The concentrations of organics are consistent with the prevailing theory of movement by diffusion in the gaseous phase. Results of tritium analyses indicate water has moved to a depth of 86 ft in 17 yr. Results of well sampling analyses indicate monitoring and sampling of perched water can be a valuable resource for understanding the hydrogeologic environment of the vadose zone at disposal sites

  8. Physicochemical transformation and algal toxicity of engineered nanoparticles in surface water samples

    International Nuclear Information System (INIS)

    Zhang, Luqing; Li, Jingyi; Yang, Kun; Liu, Jingfu; Lin, Daohui

    2016-01-01

    Most studies on the behavior and toxicity of engineered nanoparticles (NPs) have been conducted in artificial water with well-controlled conditions, which are dramatically different from natural waters with complex compositions. To better understand the fate and toxicity of NPs in the natural water environment, physicochemical transformations of four NPs (TiO_2, ZnO, Ag, and carbon nanotubes (CNTs)) and their toxicities towards a unicellular green alga (Chlorella pyrenoidosa) in four fresh water and one seawater sample were investigated. Results indicated that water chemistry had profound effects on aggregation, dissolution, and algal toxicity of the NPs. The strongest homoaggregation of the NPs was associated with the highest ionic strength, but no obvious correlation was observed between the homoaggregation of NPs and pH or dissolved organic matter content of the water samples. The greatest dissolution of ZnO NPs also occurred in seawater with the highest ionic strength, while the dissolution of Ag NPs varied differently from ZnO NPs. The released Zn"2"+ and especially Ag"+ mainly accounted for the algal toxicity of ZnO and Ag NPs, respectively. The NP-cell heteroagglomeration occurred generally for CNTs and Ag NPs, which contributed to the observed nanotoxicity. However, there was no significant correlation between the observed nanotoxicity and the type of NP or the water chemistry. It was thus concluded that the physicochemical transformations and algal toxicities of NPs in the natural water samples were caused by the combined effects of complex water quality parameters rather than any single influencing factor alone. These results will increase our knowledge on the fate and effects of NPs in the aquatic environment. - Highlights: • Transformation and algal toxicity of four NPs in five surface water samples were studied. • The transformation and toxicity were dependent on the types of NPs and water samples. • No single water parameter alone was

  9. Water and steam sampling systems; Provtagningssystem foer vatten och aanga

    Energy Technology Data Exchange (ETDEWEB)

    Hellman, Mats

    2009-10-15

    The supervision of cycle chemistry can be divided into two parts, the sampling system and the chemical analysis. In modern steam generating plants most of the chemical analyses are carried out on-line. The detection limits of these analyzers are pushed downward to the ppt-range (parts per trillion), however the analyses are not more correct than the accuracy of the sampling system. A lot of attention has been put to the analyzers and the statistics to interpret the results but the sampling procedures has gained much less attention. This report aims to give guidance of the considerations to be made regarding sampling systems. Sampling is necessary since most analysis of interesting parameters cannot be carried out in- situ on-line in the steam cycle. Today's on-line instruments for pH, conductivity, silica etc. are designed to meet a water sample at a temperature of 10-30 deg C. This means that the sampling system has to extract a representative sample from the process, transport and cool it down to room temperature without changing the characteristics of the fluid. In the literature research work, standards and other reports can be found. Although giving similar recommendations in most aspects there are some discrepancies that may be confusing. This report covers all parts in the sampling system: Sample points and nozzles; Sample lines; Valves, regulating and on-off; Sample coolers; Temperature, pressure and flow rate control; Cooling water; and Water recovery. On-line analyzers connecting to the sampling system are not covered. This report aims to clarify what guidelines are most appropriate amongst the existing ones. The report should also give guidance to the design of the sampling system in order to achieve representative samples. In addition to this the report gives an overview of the fluid mechanics involved in sampling. The target group of this report is owners and operators of steam generators, vendors of power plant equipment, consultants working in

  10. Why European Entrepreneurs in the Water and Waste Management Sector Are Willing to Go beyond Environmental Legislation

    Directory of Open Access Journals (Sweden)

    Adrián Rabadán

    2017-02-01

    Full Text Available Sustainability in the water sector in Europe is a major concern, and compliance with the current legislation alone does not seem to be enough to face major challenges like climate change or population growth and concentration. The greatest potential for improvement appears when companies decide to take a step forward and go beyond environmental legislation. This study focuses on the environmental responsibility (ER of European small and medium-sized enterprises (SMEs in the water and waste management sector and analyzes the drivers that lead these firms to the adoption of more sustainable practices. Our results show that up to 40% of European SMEs within this industry display environmental responsibility. Market pull has a low incidence in encouraging ER, while values and the strategic decisions of entrepreneurs seem decisive. Policy makers should prioritize subsidies over fiscal incentives because they show greater potential to promote the adoption of environmental responsibility among these firms.

  11. Collection and preparation of water samples for hydrogeochemical reconnaissance

    International Nuclear Information System (INIS)

    Baucom, E.I.; Ferguson, R.B.; Wallace, R.M.

    1977-01-01

    A method based on ion exchange and neutron activation analysis (NAA) was developed and field-tested to determine uranium over the range 0.02 to 10,000 ppb in natural water using a single procedure. Water samples are filtered in the field using a specially-designed one-liter filter apparatus pressurized to 40 psig with an inert gas. The filtered water is treated with a high purity, mixed cation-anion resin in the hydronium-hydroxide form. All ions are removed from solution under the strong driving force of the neutralization reaction. Anionic, cationic, and natural complexes of uranium can be concentrated with this method. Field tests showed greater than 95 percent recovery of 13 elements analyzed (including greater than 99 percent recovery of uranium) and greater than or equal to 90 percent recovery of 4 other elements. Uranium collected on the resin was quantitatively determined by NAA. Coefficient of variation for sampling plus analysis was less than 20 percent for samples containing more than 0.1 ppb uranium. Advantages of this method include: (1) wide dynamic range, (2) low detection limit for uranium (0.02 ppb), (3) high precision and accuracy, (4) relatively low cost, (5) high-yield recovery from low-level aqueous samples without risk of loss to containers, (6) decreased risk of significant sample contamination compared with other low-level methods, (7) production of stable samples suitable for retrievable storage, and(8) concentration of other ions that can be determined by NAA. This paper presents (1) background regarding development of procedures for sample collection and preparation, (2) results of development programs, (3) description of equipment and field procedures, and (4) preliminary conclusions regarding use of this technology for hydrogeochemical reconnaissance for uranium

  12. Sampling and analysis for radon-222 dissolved in ground water and surface water

    Science.gov (United States)

    DeWayne, Cecil L.; Gesell, T.F.

    1992-01-01

    Radon-222 is a naturally occurring radioactive gas in the uranium-238 decay series that has traditionally been called, simply, radon. The lung cancer risks associated with the inhalation of radon decay products have been well documented by epidemiological studies on populations of uranium miners. The realization that radon is a public health hazard has raised the need for sampling and analytical guidelines for field personnel. Several sampling and analytical methods are being used to document radon concentrations in ground water and surface water worldwide but no convenient, single set of guidelines is available. Three different sampling and analytical methods - bubbler, liquid scintillation, and field screening - are discussed in this paper. The bubbler and liquid scintillation methods have high accuracy and precision, and small analytical method detection limits of 0.2 and 10 pCi/l (picocuries per liter), respectively. The field screening method generally is used as a qualitative reconnaissance tool.

  13. SPME GC/MS determination of organochlorine pesticides in water samples

    Directory of Open Access Journals (Sweden)

    Yerbolat Sailaukhanuly

    2013-05-01

    Full Text Available Headspace solid phase microextraction (HS-SPME in combination with gas chromatography and mass-spectrometry (GC/MS was studied for analysis of water samples. The organochlorine pesticides (OCPs, p,p'-DDT, p,p'-DDD, and p,p'-DDE were collected and analyzed by GC/MS. To select of effective fiber coatings four types of SPME fibers were examined and compared. The parameters effecting the efficiency of HS-SPME such as extraction and pre-incubation time and extraction temperature, effect of solvent nature, ionic strength were studied to obtain optimal parameters. The method was developed using spiked water samples in a concentration range  10 - 500 ng/L. The calibration curve was linear over the studied concentration range with r≥0.9925. The detection limits varied from 1.57 to 2.08 ng/L. An authentic water samples from contaminated lake with OCPs were analyzed by developed method.

  14. A satellite-based climatology (1989-2012) of lake surface water temperature from AVHRR 1-km for Central European water bodies

    Science.gov (United States)

    Riffler, Michael; Wunderle, Stefan

    2013-04-01

    The temperature of lakes is an important parameter for lake ecosystems influencing the speed of physio-chemical reactions, the concentration of dissolved gazes (e.g. oxygen), and vertical mixing. Even small temperature changes might have irreversible effects on the lacustrine system due to the high specific heat capacity of water. These effects could alter the quality of lake water depending on parameters like lake size and volume. Numerous studies mention lake water temperature as an indicator of climate change and in the Global Climate Observing System (GCOS) requirements it is listed as an essential climate variable. In contrast to in situ observations, satellite imagery offers the possibility to derive spatial patterns of lake surface water temperature (LSWT) and their variability. Moreover, although for some European lakes long in situ time series are available, the temperatures of many lakes are not measured or only on a non-regular basis making these observations insufficient for climate monitoring. However, only few satellite sensors offer the possibility to analyze time series which cover more than 20 years. The Advanced Very High Resolution Radiometer (AVHRR) is among these and has been flown on the National Oceanic and Atmospheric Administration (NOAA) Polar Operational Environmental Satellites (POES) and on the Meteorological Operational Satellites (MetOp) from the European Organisation for the Exploitation of Meteorological Satellites (EUMETSAT) as a heritage instrument for almost 35 years. It will be carried on for at least ten more years finally offering a unique opportunity for satellite-based climate studies. Herein we present the results from a study initiated by the Swiss GCOS office to generate a satellite-based LSWT climatology for the pre-alpine water bodies in Switzerland. It relies on the extensive AVHRR 1-km data record (1985-2012) of the Remote Sensing Research Group at the University of Bern (RSGB) and has been derived from the AVHRR/2

  15. Set Up of an Automatic Water Quality Sampling System in Irrigation Agriculture

    Directory of Open Access Journals (Sweden)

    Emanuel Heinz

    2013-12-01

    Full Text Available We have developed a high-resolution automatic sampling system for continuous in situ measurements of stable water isotopic composition and nitrogen solutes along with hydrological information. The system facilitates concurrent monitoring of a large number of water and nutrient fluxes (ground, surface, irrigation and rain water in irrigated agriculture. For this purpose we couple an automatic sampling system with a Wavelength-Scanned Cavity Ring Down Spectrometry System (WS-CRDS for stable water isotope analysis (δ2H and δ18O, a reagentless hyperspectral UV photometer (ProPS for monitoring nitrate content and various water level sensors for hydrometric information. The automatic sampling system consists of different sampling stations equipped with pumps, a switch cabinet for valve and pump control and a computer operating the system. The complete system is operated via internet-based control software, allowing supervision from nearly anywhere. The system is currently set up at the International Rice Research Institute (Los Baños, The Philippines in a diversified rice growing system to continuously monitor water and nutrient fluxes. Here we present the system’s technical set-up and provide initial proof-of-concept with results for the isotopic composition of different water sources and nitrate values from the 2012 dry season.

  16. Effects of sterilization treatments on the analysis of TOC in water samples.

    Science.gov (United States)

    Shi, Yiming; Xu, Lingfeng; Gong, Dongqin; Lu, Jun

    2010-01-01

    Decomposition experiments conducted with and without microbial processes are commonly used to study the effects of environmental microorganisms on the degradation of organic pollutants. However, the effects of biological pretreatment (sterilization) on organic matter often have a negative impact on such experiments. Based on the principle of water total organic carbon (TOC) analysis, the effects of physical sterilization treatments on determination of TOC and other water quality parameters were investigated. The results revealed that two conventional physical sterilization treatments, autoclaving and 60Co gamma-radiation sterilization, led to the direct decomposition of some organic pollutants, resulting in remarkable errors in the analysis of TOC in water samples. Furthermore, the extent of the errors varied with the intensity and the duration of sterilization treatments. Accordingly, a novel sterilization method for water samples, 0.45 microm micro-filtration coupled with ultraviolet radiation (MCUR), was developed in the present study. The results indicated that the MCUR method was capable of exerting a high bactericidal effect on the water sample while significantly decreasing the negative impact on the analysis of TOC and other water quality parameters. Before and after sterilization treatments, the relative errors of TOC determination could be controlled to lower than 3% for water samples with different categories and concentrations of organic pollutants by using MCUR.

  17. The Alaska Commercial Fisheries Water Quality Sampling Methods and Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    Folley, G.; Pearson, L.; Crosby, C. [Alaska Dept. of Environmental Conservation, Soldotna, AK (United States); DeCola, E.; Robertson, T. [Nuka Research and Planning Group, Seldovia, AK (United States)

    2006-07-01

    A comprehensive water quality sampling program was conducted in response to the oil spill that occurred when the M/V Selendang Ayu ship ran aground near a major fishing port at Unalaska Island, Alaska in December 2004. In particular, the sampling program focused on the threat of spilled oil to the local commercial fisheries resources. Spill scientists were unable to confidently model the movement of oil away from the wreck because of limited oceanographic data. In order to determine which fish species were at risk of oil contamination, a real-time assessment of how and where the oil was moving was needed, because the wreck became a continual source of oil release for several weeks after the initial grounding. The newly developed methods and procedures used to detect whole oil during the sampling program will be presented in the Alaska Commercial Fisheries Water Quality Sampling Methods and Procedures Manual which is currently under development. The purpose of the manual is to provide instructions to spill managers while they try to determine where spilled oil has or has not been encountered. The manual will include a meaningful data set that can be analyzed in real time to assess oil movement and concentration. Sections on oil properties and processes will be included along with scientific water quality sampling methods for whole and dissolved phase oil to assess potential contamination of commercial fishery resources and gear in Alaska waters during an oil spill. The manual will present a general discussion of factors that should be considered when designing a sampling program after a spill. In order to implement Alaska's improved seafood safety measures, the spatial scope of spilled oil must be known. A water quality sampling program can provide state and federal fishery managers and food safety inspectors with important information as they identify at-risk fisheries. 11 refs., 7 figs.

  18. Evaluation of storage and filtration protocols for alpine/subalpine lake water quality samples

    Science.gov (United States)

    John L. Korfmacher; Robert C. Musselman

    2007-01-01

    Many government agencies and other organizations sample natural alpine and subalpine surface waters using varying protocols for sample storage and filtration. Simplification of protocols would be beneficial if it could be shown that sample quality is unaffected. In this study, samples collected from low ionic strength waters in alpine and subalpine lake inlets...

  19. Identification and quantification of pesticide residues in water samples of Dhamrai Upazila, Bangladesh

    Science.gov (United States)

    Hasanuzzaman, M.; Rahman, M. A.; Salam, M. A.

    2017-10-01

    Being agricultural country, different types of pesticides are widely used in Bangladesh to prevent the crop losses due to pest attack which are ultimately drain to the water bodies. The present study was conducted to identify and quantify the organochlorine (DDT, DDE and DDD), organophosphorus (malathion, diazinon and chloropyrifos) and carbamate (carbaryl) residues in water samples of different sources from Dhamrai upazila of Bangladesh using high performance liquid chromatography (HPLC) equipped with ultra violate (UV) detector. Thirty water samples from fish pond, cultivated land and tube-well were collected in winter season to analyze the pesticide residues. Among the organophosphorus pesticides, malathion was present in seven water samples ranging from 42.58 to 922.8 μg/L, whereas diazinon was detected in water sample-8 (WS-8) and the concentration was 31.5 μg/L. None of the tested water samples was found to be contaminated with chlorpyrifos, carbaryl or DDT and its metabolites (DDE and DDD). Except for a tube-well water sample, concentrations of the detected residues are above the acceptable limit for human body as assigned by different organizations. To avoid the possible health hazards, the indiscriminate application of pesticides should be restricted and various substitute products like bio-pesticide should be introduced in a broad scale as soon as possible.

  20. Water sampling using a drone at Yugama crater lake, Kusatsu-Shirane volcano, Japan

    Science.gov (United States)

    Terada, Akihiko; Morita, Yuichi; Hashimoto, Takeshi; Mori, Toshiya; Ohba, Takeshi; Yaguchi, Muga; Kanda, Wataru

    2018-04-01

    Remote sampling of water from Yugama crater lake at Kusatsu-Shirane volcano, Japan, was performed using a drone. Despite the high altitude of over 2000 m above sea level, our simple method was successful in retrieving a 250 mL sample of lake water. The procedure presented here is easy for any researcher to follow who operates a drone without additional special apparatus. We compare the lake water sampled by drone with that sampled by hand at a site where regular samplings have previously been carried out. Chemical concentrations and stable isotope ratios are largely consistent between the two techniques. As the drone can fly automatically with the aid of navigation by Global Navigation Satellite System (GNSS), it is possible to repeatedly sample lake water from the same location, even when entry to Yugama crater lake is restricted due to the risk of eruption.[Figure not available: see fulltext.

  1. Bioaccumulation and biomagnification of classical flame retardants, related halogenated natural compounds and alternative flame retardants in three delphinids from Southern European waters

    International Nuclear Information System (INIS)

    Barón, E.; Giménez, J.; Verborgh, P.; Gauffier, P.; De Stephanis, R.; Eljarrat, E.; 2O Building, Scientific and Technological Park of the University of Girona, Emili Grahit 101, 17003 Girona (Spain))" data-affiliation=" (Institute of Environmental Assessment and Water Research Studies (IDAEA), Spanish Council for Scientific Research (CSIC), Jordi Girona 18-26, 08034 Barcelona (Spain); Catalan Institute for Water Research (ICRA), H2O Building, Scientific and Technological Park of the University of Girona, Emili Grahit 101, 17003 Girona (Spain))" >Barceló, D.

    2015-01-01

    Occurrence and behaviour of classical (PBDEs) and alternative (HNs, HBB, PBEB, DBDPE and HBCD) flame retardants, together with naturally produced MeO-PBDEs, were studied in short-beaked common dolphin (Delphinus delphis), bottlenose dolphin (Tursiops truncatus) and long-finned pilot whale (Globicephala melas) in two sampling locations from Southern European waters. PBDEs, Dec 602, Dec 603, DP, α-HBCD and two MeO-PBDEs were detected in all three species. ∑PBDEs were between 17 and 2680 ng/g lw; ∑HNs were between 1.1 and 59 ng/g lw; α-HBCD levels ranged between 3.2 and 641 ng/g lw; ∑MeO-PBDEs were between 34 and 1966 ng/g lw. Bottlenose dolphins were the most contaminated species and some individuals could present health risk for endocrine disruption since levels found were above the reported threshold (1500 ng/g lw). Stable isotope analysis was used to evaluate the biomagnification capacity of these compounds. PBDEs, MeO-PBDEs and Dec 602 showed a significant positive correlation with trophic position. - Highlights: • Several FRs were detected in three dolphin species from Southern European waters. • Concentrations of classical FRs were higher than concentrations of alternative FRs. • MeO-PBDE concentrations were generally similar to PBDE concentrations. • Evidence of biomagnification capacity of some FRs was observed. • Some individuals were above the threshold level associated to endocrine disruption. - Bioaccumulation and biomagnification of halogenated compounds in dolphins

  2. Exploring the Legionella pneumophila positivity rate in hotel water samples from Antalya, Turkey.

    Science.gov (United States)

    Sepin Özen, Nevgün; Tuğlu Ataman, Şenay; Emek, Mestan

    2017-05-01

    The genus Legionella is a fastidious Gram-negative bacteria widely distributed in natural waters and man made water supply systems. Legionella pneumophila is the aetiological agent of approximately 90% of reported Legionellosis cases, and serogroup 1 is the most frequent cause of infections. Legionnaires' disease is often associated with travel and continues to be a public health concern at present. The correct water management quality practices and rapid methods for analyzing Legionella species in environmental water is a key point for the prevention of Legionnaires' disease outbreaks. This study aimed to evaluate the positivity rates and serotyping of Legionella species from water samples in the region of Antalya, Turkey, which is an important tourism center. During January-December 2010, a total of 1403 samples of water that were collected from various hotels (n = 56) located in Antalya were investigated for Legionella pneumophila. All samples were screened for L. pneumophila by culture method according to "ISO 11731-2" criteria. The culture positive Legionella strains were serologically identified by latex agglutination test. A total of 142 Legionella pneumophila isolates were recovered from 21 (37.5%) of 56 hotels. The total frequency of L. pneumophila isolation from water samples was found as 10.1%. Serological typing of 142 Legionella isolates by latex agglutination test revealed that strains belonging to L. pneumophila serogroups 2-14 predominated in the examined samples (85%), while strains of L. pneumophila serogroup 1 were less numerous (15%). According to our knowledge, our study with the greatest number of water samples from Turkey demonstrates that L. pneumophila serogroups 2-14 is the most common isolate. Rapid isolation of L. pneumophila from environmental water samples is essential for the investigation of travel related outbreaks and the possible resources. Further studies are needed to have epidemiological data and to determine the types of L

  3. Combining Mass Spectrometry and Toxicology for a Multi-Country European Epidemiologic Study on Drinking Water Disinfection By-Products

    Science.gov (United States)

    The HiWATE (Health Impacts of long-term exposure to disinfection by-products in drinking WATEr) project is the first systematic analysis that combines the epidemiology on adverse pregnancy outcomes with analytical chemistry and analytical biology in the European Union. This study...

  4. Determination of pyridine in soil and water samples of a polluted area

    International Nuclear Information System (INIS)

    Peters, R.J.B.; Renesse van Duivenbode, J.A.D. van

    1994-01-01

    A method for the analyses of pyridine in environmental samples is described. For soil samples a distillation procedure followed by an extraction, an acidic extraction or a Soxhlet extraction can be used. For water samples a distillation procedure followed by extraction can be employed. Deuterated pyridine is used as an internal standard and the extracts are analyzed by GC-MS. The recoveries of the methods are higher than 80%; the detection limits for pyridine are 0.01 mg/kg for soil samples and 0.2 μg/l for water samples. (orig.)

  5. Franco-German nuclear cooperation: from the 'common product' to the first European pressurized water reactor

    International Nuclear Information System (INIS)

    Vignon, D.

    1999-01-01

    It has now been 10 years since Framatome and Siemens decided to collaborate on the design and sales of an advanced nuclear power plant (NPP) model based on pressurized water reactor (PWR) technology. Originally called the 'common product', this model was renamed the European pressurized water reactor when Electricite de France (EDF) and the German electric utilities joined this cooperative development effort in 1992. Since the beginning, this cooperation has been formalized in the framework of an agreement that led to the founding of a joint and equally owned subsidiary, Nucler Power International (NPI), which is reponsible for leading the development of the new model and later handling its export sales

  6. A QUANTITATIVE EVALUATION OF THE WATER DISTRIBUTION IN A SOIL SAMPLE USING NEUTRON IMAGING

    Directory of Open Access Journals (Sweden)

    Jan Šácha

    2016-10-01

    Full Text Available This paper presents an empirical method by Kang et al. recently proposed for correcting two-dimensional neutron radiography for water quantification in soil. The method was tested on data from neutron imaging of the water infiltration in a soil sample. The raw data were affected by neutron scattering and by beam hardening artefacts. Two strategies for identifying the correction parameters are proposed in this paper. The method has been further developed for the case of three-dimensional neutron tomography. In a related experiment, neutron imaging is used to record ponded-infiltration experiments in two artificial soil samples. Radiograms, i.e., two-dimensional projections of the sample, were acquired during infiltration. A calculation was made of the amount of water and its distribution within the radiograms, in the form of two-dimensional water thickness maps. Tomograms were reconstructed from the corrected and uncorrected water thickness maps to obtain the 3D spatial distribution of the water content within the sample. Without the correction, the beam hardening and the scattering effects overestimated the water content values close to the perimeter of the sample, and at the same time underestimated the values close to the centre of the sample. The total water content of the entire sample was the same in both cases. The empirical correction method presented in this study is a relatively accurate, rapid and simple way to obtain the quantitatively determined water content from two-dimensional and three-dimensional neutron images. However, an independent method for measuring the total water volume in the sample is needed in order to identify the correction parameters.

  7. Environmental costs of a river watershed within the European water framework directive: Results from physical hydronomics

    International Nuclear Information System (INIS)

    Martinez, A.; Uche, J.; Valero, A.; Valero-Delgado, A.

    2010-01-01

    Physical hydronomics (PH) is the specific application of thermodynamics that physically characterizes the governance of water bodies, i.e., the Water Framework Directive (WFD) for European Union citizens. In this paper, calculation procedures for the exergy analysis of river basins are developed within the WFD guidelines and a case study is developed. Therefore, it serves as an example for the feasible application of PH in the environmental cost assessment of water bodies, accordingly to the principle of recovery of the costs related to water services in accordance with the polluter pays principle, one of the milestones of the WFD. The Foix River watershed, a small river located at the Inland Basins of Catalonia (IBC), has been analyzed. Main results, difficulties, and constraints encountered are shown in the paper. Following WFD's quantity and quality objectives previously defined, water costs are calculated and the equivalence between the exergy loss due to water users and the exergy variation along the river are also analyzed.

  8. Development of a water quality index based on a European ...

    African Journals Online (AJOL)

    2006-08-24

    Aug 24, 2006 ... The mathematical equations to transform the actual concentration values ... The application of the new index was demonstrated at a sampling station on ..... Descriptive statistics of reservoir water quality data set. Variable. Unit.

  9. European Drought and Water Scarcity Policies

    NARCIS (Netherlands)

    Özerol, Gül; Stein, Ulf; Troeltzsch, Jenny; Landgrebe, Ruta; Szendrenyi, Anna; Vidaurre, Rodrigo; Bressers, Hans; Bressers, Nanny; Larrue, Corinne

    2016-01-01

    Over the last decade, Europe’s drought management and policy has been characterized by a predominantly crisis-oriented approach. However, the widening gap between the impacts of drought episodes and the ability to prepare, manage and mitigate such droughts has motivated the European Union (EU) to

  10. Preconcentration and determination of heavy metals in water, sediment and biological samples

    Directory of Open Access Journals (Sweden)

    Shirkhanloo Hamid

    2011-01-01

    Full Text Available In this study, a simple, sensitive and accurate column preconcentration method was developed for the determination of Cd, Cu and Pb ions in river water, urine and sediment samples by flame atomic absorption spectrometry. The procedure is based on the retention of the analytes on a mixed cellulose ester membrane (MCEM column from buffered sample solutions and then their elution from the column with nitric acid. Several parameters, such as pH of the sample solution, volume of the sample and eluent and flow rates of the sample were evaluated. The effects of diverse ions on the preconcentration were also investigated. The recoveries were >95 %. The developed method was applied to the determination of trace metal ions in river water, urine and sediment samples, with satisfactory results. The 3δ detection limits for Cu, Pb and Cd were found to be 2, 3 and 0.2 μg dm−3, respectively. The presented procedure was successfully applied for determination of the copper, lead and cadmium contents in real samples, i.e., river water and biological samples.

  11. Estimating the tritium input to groundwater from wine samples: Groundwater and direct run-off contribution to Central European surface waters

    International Nuclear Information System (INIS)

    Roether, W.

    1967-01-01

    A model is derived which allows a quantitative evaluation of wine tritium data. It is shown that the tritium content of a wine sample is not determined exclusively by water taken up by the roots, but is also influenced to a large extent by direct exchange with atmospheric moisture. The soil-water fraction amounts normally to not more than 40%. Thus, wine is a sample partly of atmospheric moisture at ground level, partly of soil moisture, integrated over a period around three weeks before vintage. The tritium content of two sets of wine samples originating from two selected sites in the Federal Republic of Germany and dating back to 1949 is reported. For the period since records of the tritium content of rain in Europe have become available comparisons of wine tritium with reported tritium activities of rain are in favour of the model outlined. The first distinguishable influence of bomb tritium shows up in the 1953 wine, whilst no detectable response to Castle tritium is found in 1954. By comparison with recorded rain activities at Ottawa, Canada, it is concluded that Castle influenced the tritium fall-out in Central Europe much less than it did at Ottawa. For the period before 1955 the tritium activity of the annual groundwater recharge, including pre-thermonuclear recharge in Central Europe, is estimated from the wine data. An estimation of the total assimilation of pre-thermonuclear tritium into the ocean at 50 degrees N is also given, which points to a value of 1-1.5 atoms/cm 2 s. It is shown that in further uses of pre-thermonuclear wines the possibility that samples have been contaminated by penetration of thermonuclear tritium through the bottle seals must be considered. The estimates of the tritium activities of groundwater recharge are based on the fact that in our climate the main contribution to groundwater is made up by autumn and winter precipitation. Because of this correlation with season the groundwater recharge is much lower in tritium than the

  12. Summary of Inorganic Compositional Data for Groundwater, Soil-Water, and Surface-Water Samples at the Headgate Draw Subsurface Drip Irrigation Site

    Energy Technology Data Exchange (ETDEWEB)

    Geboy, Nicholas J.; Engle, Mark A.; Schroeder, Karl T.; Zupanic, John W.

    2007-01-01

    As part of a 5-year project on the impact of subsurface drip irrigation (SDI) application of coalbed-methane (CBM) produced waters, water samples were collected from the Headgate Draw SDI site in the Powder River Basin, Wyoming, USA. This research is part of a larger study to understand short- and long-term impacts on both soil and water quality from the beneficial use of CBM waters to grow forage crops through use of SDI. This document provides a summary of the context, sampling methodology, and quality assurance and quality control documentation of samples collected prior to and over the first year of SDI operation at the site (May 2008-October 2009). This report contains an associated database containing inorganic compositional data, water-quality criteria parameters, and calculated geochemical parameters for samples of groundwater, soil water, surface water, treated CBM waters, and as-received CBM waters collected at the Headgate Draw SDI site.

  13. The european passive plant (EPP) design: compliance with the european utilities requirements (EUR)

    International Nuclear Information System (INIS)

    Noviello, L.; Oyarzabal, M.

    1996-01-01

    Back 1986, most of the European firms have participated to the American program called the Advanced Light Water Reactors (ALWR) including the development of the Utilities Requirements as well as four projects as for instance AP600. Later, in the year 1990, seven European firms have begun to develop the European Utilities Requirements. This development is justified by the fact that the lessons learned by the nuclear power plants designs programs of the years 1980 can be incorporated and the European specific conditions can be taken into consideration. Thus, in 1994, eight European firms - Westinghouse and their industrial partners - have decided to launch a multiphase program in order to check the AP600 compliance with the European Utilities Requirements (EUR) and to develop the required alterations. Today, the phase I of the EPP (European Passive Plant) program has been completed. In this phase, the main important objectives have been reached. (O.M.)

  14. Seasonal Variations in Stable Isotope Ratios of Oxygen and Hydrogen in Two Tundra Rivers in NE European Russia

    Energy Technology Data Exchange (ETDEWEB)

    Huitu, E.; Arvola, L. [Lammi Biological Station, University of Helsinki (Finland); Sonninen, E. [Radiocarbon Dating Laboratory, University of Helsinki (Finland)

    2013-07-15

    The variability in stable isotope ratios of oxygen and hydrogen ({delta} {sup 18}O and {delta}{sup 2}H values) in river waters in northeast European Russia was studied for the period from July 2007 to october 2008. Exceptional isotope composition in precipitation obtained during the sampling period was clearly traced in the composition of river waters. Water from permafrost thawing did not make a great contribution to river flow. (author)

  15. A confirmatory holding time study for purgeable VOCs in water samples

    International Nuclear Information System (INIS)

    West, O.R.; Bayne, C.K.; Siegrist, R.L.; Holden, W.H.; Bottrell, D.W.

    1996-01-01

    Analyte stability during pre-analytical storage is essential to the accurate quantification contaminants in environmental samples. This is particularly true for volatile organic compounds (VOCS) which can easily volatilize and/or degrade during sample storage. Recognizing this, regulatory agencies require water samples be collected in vials without headspace and stored at 4 degrees C, and that analyses be conducted within 14 days, 2048 even if samples are acid-preserved. Since the selection of a 14-day holding time was largely arbitrary, the appropriateness of this requirement must be re-evaluated. The goal of the study described here was to provide regulatory agencies with the necessary data to extend the maximum holding time for properly preserved VOC water samples to 28 days

  16. Genotoxicity assessment of water sampled from R-11 reservoir by means of allium test

    Energy Technology Data Exchange (ETDEWEB)

    Bukatich, E.; Pryakhin, E. [Urals Research Center for Radiation Medicine (Russian Federation); Geraskin, S. [Russian Institute of Agricultural Radiology and Agroecology (Russian Federation)

    2014-07-01

    The Mayak PA was the first enterprise for the production of weapon-grade plutonium in Russia and it incorporates uranium-graphite reactors for plutonium production and radiochemical facilities for its separation. Radiochemical processing resulted in huge volumes of liquid radioactive wastes of different specific activities. To reduce the radionuclides release into the environment, a system of bypasses and ponds (the Techa Cascade Reservoirs system) to store low-activity liquid wastes has been constructed in the upper reaches of the Techa River. Currently, industrial reservoirs of Mayak PA contain over 350 million m{sup 3} of low-level radioactive liquid wastes with total activity over 7.4 x 10{sup 15} Bq. Reservoir R-11 is the final reservoir in the Techa Cascade Reservoirs system. The average specific activity of main radionuclides in the water of R-11 are: {sup 90}Sr - 1.4x10{sup 3} Bq/l; {sup 137}Cs - 3 Bq/l; {sup 3}H - 7x10{sup 2} Bq/l; α-emitting radionuclides - 2.6 x 10{sup -1} Bq/l. In our study the Allium-test was employed to estimate reservoir R-11 water genotoxic effects. In 2012, 3 water samples were collected in different parts of reservoir R-11. Water samples from the Shershnevskoye reservoir (artificial reservoir on the Miass River designed for Chelyabinsk city water supply) were used as natural control. Samples of distilled and bottled water were used as an additional laboratory control. The common onion, Allium cepa L. (Stuttgarter Riesen) was used. Healthy equal-sized bulbs were soaked for 24 hours at +4±2 deg. C to synchronize cell division. The bulbs were maintained in distilled water at +23 deg. C until roots have grown up to 2±1 mm length and then plunged into water samples. Control samples remained in distilled and bottled water as well as in water samples from the Shershnevskoye reservoir (natural control). Roots of the 18±3 mm length were randomly sampled and fixed in an alcohol/acetic acid mixture. For microscopic analysis, squashed

  17. Comparison of POCIS passive samplers vs. composite water sampling: A case study.

    Science.gov (United States)

    Criquet, Justine; Dumoulin, David; Howsam, Michael; Mondamert, Leslie; Goossens, Jean-François; Prygiel, Jean; Billon, Gabriel

    2017-12-31

    The relevance of Polar Organic Chemical Integrative Samplers (POCIS) was evaluated for the assessment of concentrations of 46 pesticides and 19 pharmaceuticals in a small, peri-urban river with multi-origin inputs. Throughout the period of POCIS deployment, 24h-average water samples were collected automatically, and showed the rapid temporal evolution of concentrations of several micropollutants, as well as permitting the calculation of average concentrations in the water phase for comparison with those estimated from POCIS passive samplers. In the daily water samples, cyproconazol, epoxyconazol and imidacloprid showed high temporal variations with concentrations ranging from under the limit of detection up to several hundreds of ngL -1 . Erythromycin, cyprofloxacin and iopromide also increased rapidly up to tens of ngL -1 within a few days. Conversely, atrazine, caffeine, diclofenac, and to a lesser extent carbamazepine and sucralose, were systematically present in the water samples and showed limited variation in concentrations. For most of the substances studied here, the passive samplers gave reliable average concentrations between the minimal and maximal daily concentrations during the time of deployment. For pesticides, a relatively good correlation was clearly established (R 2 =0.89) between the concentrations obtained by POCIS and those gained from average water samples. A slight underestimation of the concentration by POCIS can be attributed to inappropriate sampling rates extracted from the literature and for our system, and new values are proposed. Considering the all data set, 75% of the results indicate a relatively good agreement between the POCIS and the average water samples concentration (values of the ratio ranging between 0,33 and 3). Note further that this agreement between these concentrations remains valid considering different sampling rates extracted from the literature. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. WAVE-E: The WAter Vapour European-Explorer Mission

    Science.gov (United States)

    Jimenez-LLuva, David; Deiml, Michael; Pavesi, Sara

    2017-04-01

    In the last decade, stratosphere-troposphere coupling processes in the Upper Troposphere Lower Stratosphere (UTLS) have been increasingly recognized to severely impact surface climate and high-impact weather phenomena. Weakened stratospheric circumpolar jets have been linked to worldwide extreme temperature and high-precipitation events, while anomalously strong stratospheric jets can lead to an increase in surface winds and tropical cyclone intensity. Moreover, stratospheric water vapor has been identified as an important forcing for global decadal surface climate change. In the past years, operational weather forecast and climate models have adapted a high vertical resolution in the UTLS region in order to capture the dynamical processes occurring in this highly stratified region. However, there is an evident lack of available measurements in the UTLS region to consistently support these models and further improve process understanding. Consequently, both the IPCC fifth assessment report and the ESA-GEWEX report 'Earth Observation and Water Cycle Science Priorities' have identified an urgent need for long-term observations and improved process understanding in the UTLS region. To close this gap, the authors propose the 'WAter Vapour European - Explorer' (WAVE-E) space mission, whose primary goal is to monitor water vapor in the UTLS at 1 km vertical, 25 km horizontal and sub-daily temporal resolution. WAVE-E consists of three quasi-identical small ( 500 kg) satellites (WAVE-E 1-3) in a constellation of Sun-Synchronous Low Earth Orbits, each carrying a limb sounding and cross-track scanning mid-infrared passive spectrometer (824 cm-1 to 829 cm-1). The core of the instruments builds a monolithic, field-widened type of Michelson interferometer without any moving parts, rendering it rigid and fault tolerant. Synergistic use of WAVE-E and MetOp-NG operational satellites is identified, such that a data fusion algorithm could provide water vapour profiles from the

  19. Use of an Electronic Tongue System and Fuzzy Logic to Analyze Water Samples

    Science.gov (United States)

    Braga, Guilherme S.; Paterno, Leonardo G.; Fonseca, Fernando J.

    2009-05-01

    An electronic tongue (ET) system incorporating 8 chemical sensors was used in combination with two pattern recognition tools, namely principal component analysis (PCA) and Fuzzy logic for discriminating/classification of water samples from different sources (tap, distilled and three brands of mineral water). The Fuzzy program exhibited a higher accuracy than the PCA and allowed the ET to classify correctly 4 in 5 types of water. Exception was made for one brand of mineral water which was sometimes misclassified as tap water. On the other hand, the PCA grouped water samples in three clusters, one with the distilled water; a second with tap water and one brand of mineral water, and the third with the other two other brands of mineral water. Samples in the second and third clusters could not be distinguished. Nevertheless, close grouping between repeated tests indicated that the ET system response is reproducible. The potential use of the Fuzzy logic as the data processing tool in combination with an electronic tongue system is discussed.

  20. Tritium analysis in environmental samples around Nuclear Power Plants and nationwide surveillance of radionuclides in some environmental samples(meat and drinking water)

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yong Woo; Han, Man Jung; Cho, Seong Won; Cho, Hong Jun; Oh, Hyeon Kyun; Lee, Jeong Min; Chang, Jae Sook [KORTIC, Taejon (Korea, Republic of)

    2001-12-15

    12 kind of environmental samples such as soil, underground water, seawater, etc. around the Nuclear Power Plants(NPP) and surface seawater around the Korea peninsula were sampled, For the samples of rain, pine-needle, air, seawater, underground water, chinese cabbage, grain of rice and milk sampled around NPP, and surface seawater and rain sampled all around country, tritium concentration was measured, The tritium concentration in the tap water and the gamma activity in the domestic and imported beef that were sampled at ward in the large city in Korea(Seoul, Pusan, Taegu, Taejun, Inchun, Kwangju) were analyzed for the meat and drinking waters. As the results of analyzing, tritium concentration in rain and tap water were very low all around country, but a little higher around the NPP than general surrounding. At the Wolsung NPP, tritium concentration was descend according to distance from the stack. Tritium activity of surface seawater around the Korea peninsula was also, very low. The measured radioactive elements in the beef is the same as the radioactive elements on the earth surface.

  1. Societal Drivers of European Water Governance: A Comparison of Urban River Restoration Practices in France and Germany

    Directory of Open Access Journals (Sweden)

    Aude Zingraff-Hamed

    2017-03-01

    Full Text Available The European water governance took a decisive turn with the formulation of the Water Framework Directive (WFD, which demands the restoration of all water bodies that did not achieve sufficient ecological status. Urban rivers are particularly impaired by human activities and their restorations are motivated by multiple ecological and societal drivers, such as requirements of laws and legislation, and citizen needs for a better quality of life. In this study we investigated the relative influence of socio-political and socio-cultural drivers on urban river restorations by comparing projects of different policy contexts and cultural norms to cross-fertilize knowledge. A database of 75 projects in French and German major cities was compiled to apply (a a comparative statistical analysis of main project features, i.e., motivation, goals, measures, morphological status, and project date; and (b a qualitative textual analysis on project descriptions and titles. The results showed that despite a powerful European directive, urban river restoration projects still keep national specificities. The WFD drives with more intensity German, rather than French, urban river restoration. This study showed the limits of macro-level governance and the influence of microlevel governance driven by societal aspects such as nature perception and relationships between humans and rivers.

  2. Concentration of polycyclic aromatic hydrocarbons in water samples from different stages of treatment

    Science.gov (United States)

    Pogorzelec, Marta; Piekarska, Katarzyna

    2017-11-01

    The aim of this study was to analyze the presence and concentration of selected polycyclic aromatic hydrocarbons in water samples from different stages of treatment and to verify the usefulness of semipermeable membrane devices for analysis of drinking water. For this purpose, study was conducted for a period of 5 months. Semipermeable membrane devices were deployed in a surface water treatment plant located in Lower Silesia (Poland). To determine the effect of water treatment on concentration of PAHs, three sampling places were chosen: raw water input, stream of water just before disinfection and treated water output. After each month of sampling SPMDs were changed for fresh ones and prepared for further analysis. Concentrations of fifteen polycyclic aromatic hydrocarbons were determined by high performance liquid chromatography (HPLC). Presented study indicates that the use of semipermeable membrane devices can be an effective tool for the analysis of aquatic environment, including monitoring of drinking water, where organic micropollutants are present at very low concentrations.

  3. Concentration of polycyclic aromatic hydrocarbons in water samples from different stages of treatment

    Directory of Open Access Journals (Sweden)

    Pogorzelec Marta

    2017-01-01

    Full Text Available The aim of this study was to analyze the presence and concentration of selected polycyclic aromatic hydrocarbons in water samples from different stages of treatment and to verify the usefulness of semipermeable membrane devices for analysis of drinking water. For this purpose, study was conducted for a period of 5 months. Semipermeable membrane devices were deployed in a surface water treatment plant located in Lower Silesia (Poland. To determine the effect of water treatment on concentration of PAHs, three sampling places were chosen: raw water input, stream of water just before disinfection and treated water output. After each month of sampling SPMDs were changed for fresh ones and prepared for further analysis. Concentrations of fifteen polycyclic aromatic hydrocarbons were determined by high performance liquid chromatography (HPLC. Presented study indicates that the use of semipermeable membrane devices can be an effective tool for the analysis of aquatic environment, including monitoring of drinking water, where organic micropollutants are present at very low concentrations.

  4. European research and development programme for water-cooled lithium-lead blankets: present status and future work

    International Nuclear Information System (INIS)

    Giancarli, L.; Leroy, P.; Proust, E.; Raepsaet, X.

    1992-01-01

    The European R and D programme in support of the development of water-cooled Pb-17Li blankets for DEMO aims at improving the data base concerning tritium behaviour and compatibility between blanket materials. The four main areas of the experimental programme are structural material corrosion by Pb-17Li, tritium extraction and permeation control.=, Pb-17Li physico-chemistry, and water/Pb-17Li interaction. This paper describes the most significant results obtained to date in the various experiments performed in Europe and the future programme required to complete the data base by 1994. 28 refs

  5. Forsmark site investigation. Hydrochemical monitoring of groundwaters and surface waters. Results from water sampling in the Forsmark area, January-December 2009

    Energy Technology Data Exchange (ETDEWEB)

    Nilsson, Ann-Chatrin (ed.); Berg, Cecilia; Harrstroem, Johan; Joensson, Stig; Thur, Pernilla (Geosigma AB (Sweden)); Borgiel, Micke; Qvarfordt, Susanne (Sveriges Vattenekologer AB (Sweden))

    2010-09-15

    The fifth year (2009) of hydrochemical monitoring of groundwaters, surface waters and precipitation in Forsmark is documented in the report. The hydrochemical monitoring programme 2009 included water sampling from: - percussion- and core boreholes equipped with installations for long-term pressure monitoring, tracer tests and water sampling in packed off borehole sections, sampling and analysis performed twice (spring and autumn), - near surface groundwaters (sampling four times a year), - private wells (once per year in October), - surface waters (eleven sampling occasions per year). Due to the somewhat different performance of the hydrogeochemical monitoring of the deep groundwaters during the autumn 2009 compared to previous years, some new findings and knowledge were obtained: 1) Removal of water volumes corresponding to three to five times the volume of the borehole section (the routine procedure) is seldom enough to obtain a complete exchange of the water present in the borehole section when the pumping starts. 2) It is likely that the elevated sulphide concentrations observed in the monitoring programme /1/ is due to contamination from initial water present in the borehole sections when the pumping starts. This water may have a very high sulphide concentration. Dirty water in tubes and in stand pipes may also contribute to the enhanced sulphide concentration. 3) Plug flow calculations will be introduced in the future as a new routine procedure to estimate the water volumes to be removed, in order to exchange the section water volume, prior to groundwater sampling in delimited borehole sections. During the autumn sampling, sample series of five samples per sampling location were collected during continuous pumping in thirteen selected borehole sections. Furthermore, special efforts were put on cleaning of stand pipes and exchange of water prior to sampling. The analytical protocol was rather extensive and included sulphide and uranium analyses for each sample

  6. Forsmark site investigation. Hydrochemical monitoring of groundwaters and surface waters. Results from water sampling in the Forsmark area, January-December 2009

    International Nuclear Information System (INIS)

    Nilsson, Ann-Chatrin; Borgiel, Micke; Qvarfordt, Susanne

    2010-09-01

    The fifth year (2009) of hydrochemical monitoring of groundwaters, surface waters and precipitation in Forsmark is documented in the report. The hydrochemical monitoring programme 2009 included water sampling from: - percussion- and core boreholes equipped with installations for long-term pressure monitoring, tracer tests and water sampling in packed off borehole sections, sampling and analysis performed twice (spring and autumn), - near surface groundwaters (sampling four times a year), - private wells (once per year in October), - surface waters (eleven sampling occasions per year). Due to the somewhat different performance of the hydrogeochemical monitoring of the deep groundwaters during the autumn 2009 compared to previous years, some new findings and knowledge were obtained: 1) Removal of water volumes corresponding to three to five times the volume of the borehole section (the routine procedure) is seldom enough to obtain a complete exchange of the water present in the borehole section when the pumping starts. 2) It is likely that the elevated sulphide concentrations observed in the monitoring programme /1/ is due to contamination from initial water present in the borehole sections when the pumping starts. This water may have a very high sulphide concentration. Dirty water in tubes and in stand pipes may also contribute to the enhanced sulphide concentration. 3) Plug flow calculations will be introduced in the future as a new routine procedure to estimate the water volumes to be removed, in order to exchange the section water volume, prior to groundwater sampling in delimited borehole sections. During the autumn sampling, sample series of five samples per sampling location were collected during continuous pumping in thirteen selected borehole sections. Furthermore, special efforts were put on cleaning of stand pipes and exchange of water prior to sampling. The analytical protocol was rather extensive and included sulphide and uranium analyses for each sample

  7. The relationship between phytoplankton distribution and water column characteristics in North West European shelf sea waters.

    Science.gov (United States)

    Fehling, Johanna; Davidson, Keith; Bolch, Christopher J S; Brand, Tim D; Narayanaswamy, Bhavani E

    2012-01-01

    Phytoplankton underpin the marine food web in shelf seas, with some species having properties that are harmful to human health and coastal aquaculture. Pressures such as climate change and anthropogenic nutrient input are hypothesized to influence phytoplankton community composition and distribution. Yet the primary environmental drivers in shelf seas are poorly understood. To begin to address this in North Western European waters, the phytoplankton community composition was assessed in light of measured physical and chemical drivers during the "Ellett Line" cruise of autumn 2001 across the Scottish Continental shelf and into adjacent open Atlantic waters. Spatial variability existed in both phytoplankton and environmental conditions, with clear differences not only between on and off shelf stations but also between different on shelf locations. Temperature/salinity plots demonstrated different water masses existed in the region. In turn, principal component analysis (PCA), of the measured environmental conditions (temperature, salinity, water density and inorganic nutrient concentrations) clearly discriminated between shelf and oceanic stations on the basis of DIN:DSi ratio that was correlated with both salinity and temperature. Discrimination between shelf stations was also related to this ratio, but also the concentration of DIN and DSi. The phytoplankton community was diatom dominated, with multidimensional scaling (MDS) demonstrating spatial variability in its composition. Redundancy analysis (RDA) was used to investigate the link between environment and the phytoplankton community. This demonstrated a significant relationship between community composition and water mass as indexed by salinity (whole community), and both salinity and DIN:DSi (diatoms alone). Diatoms of the Pseudo-nitzschia seriata group occurred at densities potentially harmful to shellfish aquaculture, with the potential for toxicity being elevated by the likelihood of DSi limitation of

  8. The relationship between phytoplankton distribution and water column characteristics in North West European shelf sea waters.

    Directory of Open Access Journals (Sweden)

    Johanna Fehling

    Full Text Available Phytoplankton underpin the marine food web in shelf seas, with some species having properties that are harmful to human health and coastal aquaculture. Pressures such as climate change and anthropogenic nutrient input are hypothesized to influence phytoplankton community composition and distribution. Yet the primary environmental drivers in shelf seas are poorly understood. To begin to address this in North Western European waters, the phytoplankton community composition was assessed in light of measured physical and chemical drivers during the "Ellett Line" cruise of autumn 2001 across the Scottish Continental shelf and into adjacent open Atlantic waters. Spatial variability existed in both phytoplankton and environmental conditions, with clear differences not only between on and off shelf stations but also between different on shelf locations. Temperature/salinity plots demonstrated different water masses existed in the region. In turn, principal component analysis (PCA, of the measured environmental conditions (temperature, salinity, water density and inorganic nutrient concentrations clearly discriminated between shelf and oceanic stations on the basis of DIN:DSi ratio that was correlated with both salinity and temperature. Discrimination between shelf stations was also related to this ratio, but also the concentration of DIN and DSi. The phytoplankton community was diatom dominated, with multidimensional scaling (MDS demonstrating spatial variability in its composition. Redundancy analysis (RDA was used to investigate the link between environment and the phytoplankton community. This demonstrated a significant relationship between community composition and water mass as indexed by salinity (whole community, and both salinity and DIN:DSi (diatoms alone. Diatoms of the Pseudo-nitzschia seriata group occurred at densities potentially harmful to shellfish aquaculture, with the potential for toxicity being elevated by the likelihood of DSi

  9. Evaluation of the Bacterial Status of Water Samples at Umudike Abia ...

    African Journals Online (AJOL)

    77.78%), Proteus spp.(66.67%), Serratia spp.(55.5%) and Vibro spp.(22.2%). The occurrence of the water borne pathogens appeared limited to the stream water samples, hence, continuous consumption without adequate treatment is potentially dangerous. Keywords: Water, rainwater, stream, bacteria, coliforms, pathogen ...

  10. Algae viability over time in a ballast water sample

    Science.gov (United States)

    Gollasch, Stephan; David, Matej

    2018-03-01

    The biology of vessels' ballast water needs to be analysed for several reasons, one of these being performance tests of ballast water management systems. This analysis includes a viability assessment of phytoplankton. To overcome logistical problems to get algae sample processing gear on board of a vessel to document algae viability, samples may be transported to land-based laboratories. Concerns were raised how the storage conditions of the sample may impact algae viability over time and what the most appropriate storage conditions were. Here we answer these questions with a long-term algae viability study with daily sample analysis using Pulse-Amplitude Modulated (PAM) fluorometry. The sample was analysed over 79 days. We tested different storage conditions: fridge and room temperature with and without light. It seems that during the first two weeks of the experiment the viability remains almost unchanged with a slight downwards trend. In the continuing period, before the sample was split, a slightly stronger downwards viability trend was observed, which occurred at a similar rate towards the end of the experiment. After the sample was split, the strongest viability reduction was measured for the sample stored without light at room temperature. We concluded that the storage conditions, especially regarding temperature and light exposure, have a stronger impact on algae viability compared to the storage duration and that inappropriate storage conditions reduce algal viability. A sample storage time of up to two weeks in a dark and cool environment has little influence on the organism viability. This indicates that a two week time duration between sample taking on board a vessel and the viability measurement in a land-based laboratory may not be very critical.

  11. EUROPEAN POLICY CONCERNING THE PROTECTION OF THE QUALITY OF THE ENVIRONMENTAL FACTOR - WATER

    Directory of Open Access Journals (Sweden)

    FLORICA BRASOVEANU

    2012-05-01

    Full Text Available European Union environmental policy, as was established in the EC Treaty aims at ensuring environmental sustainability activities through its inclusion in EU sectoral policies, by developing measures to prevent by following the basic principles of sustainable development and by taking joint responsibilities. Environmental legislation is one of those tools that combine management of natural resources with the prevention and control of the pollution. These laws attempt to prevent, or at least limit the effects of environmental degradation caused by the phenomenon of pollution. Environmental legislation should primarily be flexible in the sense to allow the fulfillment of current and the future goals in order to stimulate sustainable development concept and to base on general criteria for the purposes of allowing the extension to complex environmental problems. The environmental legislation is due to focus on integrating the source - effect policy, that is to focus on regulations for issuing permits for pollution, but also the responsibility of companies and citizens.Despite the significant improvements that have occurred especially in reducing air and water pollution, European legislation should be developed further. It is true that there are still many points that require completion and perfection, but the path followed is the best. In the European Union the process of implementation and adoption of new regulations on environmental protection (regulations, directives, decisions,recommendations to combat the causes of degradation of environmental quality and life quality time with them continues.

  12. Determination of anionic concentrations in ground water samples using ion chromatography

    International Nuclear Information System (INIS)

    Prathibha, P.; Saradhi, I.V.; Pandit, G.G.; Puranik, V.D.

    2011-01-01

    Ion chromatography is a powerful separation technique for the quantitative measurement of anions in aqueous samples as well as in soil, sediment and air particulate samples leached in aqueous solutions. Ion chromatographic technique is developed by making use of suppressed ion conductivity detection (Small et.al.,1975) and it is a rapid multi ion analysis technique. The time, processing and effort required for the analysis of anions is much less compared to other techniques available such as ion selective electrode technique. In the present paper ground water samples collected around New BARC campus, Visakhapatnam are analyzed for anions using Ion chromatograph. The data generated will establish the current baseline status of the ionic contaminants in the study area. Groundwater samples are collected at 13 locations around BARC Vizag campus covering 30 km radius in September, 2009, April and July, 2010. The water samples include samples from hand pump and open wells in villages. The water samples are analyzed for fluoride, chloride, nitrate and sulphate using Metrohm make Ion chromatograph. The fluoride concentration in samples varied from 0.22 to 1.26 ppm, chloride from 18.7 to 810.9, nitrate from 1.34 to 378.5 ppm and sulphate from 13.29 to 250.69 ppm. No significant seasonal variations are observed in the samples collected from various locations except chloride at two locations. Ions Chromatograph is found to be a useful tool for simultaneous analysis of environmental samples with good accuracy where the concentrations of anions vary within an order of magnitude among them themselves. (author)

  13. Recovery of diverse microbes in high turbidity surface water samples using dead-end ultrafiltration.

    Science.gov (United States)

    Mull, Bonnie; Hill, Vincent R

    2012-12-01

    Dead-end ultrafiltration (DEUF) has been reported to be a simple, field-deployable technique for recovering bacteria, viruses, and parasites from large-volume water samples for water quality testing and waterborne disease investigations. While DEUF has been reported for application to water samples having relatively low turbidity, little information is available regarding recovery efficiencies for this technique when applied to sampling turbid water samples such as those commonly found in lakes and rivers. This study evaluated the effectiveness of a DEUF technique for recovering MS2 bacteriophage, enterococci, Escherichia coli, Clostridium perfringens, and Cryptosporidium parvum oocysts in surface water samples having elevated turbidity. Average recovery efficiencies for each study microbe across all turbidity ranges were: MS2 (66%), C. parvum (49%), enterococci (85%), E. coli (81%), and C. perfringens (63%). The recovery efficiencies for MS2 and C. perfringens exhibited an inversely proportional relationship with turbidity, however no significant differences in recovery were observed for C. parvum, enterococci, or E. coli. Although ultrafilter clogging was observed, the DEUF method was able to process 100-L surface water samples at each turbidity level within 60 min. This study supports the use of the DEUF method for recovering a wide array of microbes in large-volume surface water samples having medium to high turbidity. Published by Elsevier B.V.

  14. Monitoring and sampling perched ground water in a basaltic terrain

    International Nuclear Information System (INIS)

    Hubbell, J.M.

    1990-01-01

    Perched ground water zones can provide significant information on water and contaminant movement. This paper presents information about perched ground water obtained from drilling and monitoring at a hazardous and radioactive waste disposal site at the Idaho National Engineering Laboratory. Six of forty-five wells drilled at the Radioactive Waste Management Complex have detected perched water in basalts above sedimentary interbeds. This paper describes the distribution and characteristics of perched ground water. It discusses perched water below the surficial sediments in wells at the RWMC, the characteristics of chemical constituents found in perched water, the implications for contaminant transport in the unsaturated zone of water, and the lateral extent of perched water. Recommendations are made to increase the probability of detecting and sampling low yield perched water zones. 6 refs., 6 figs., 2 tabs

  15. UMTRA project water sampling and analysis plan, Durango, Colorado

    International Nuclear Information System (INIS)

    1994-01-01

    Surface remedial action has been completed at the Uranium Mill Tailings Remedial Action Project in Durango, Colorado. Contaminated soil and debris have been removed from the former processing site and placed in the Bodo Canyon disposal cell. Ground water at the former uranium mill/tailings site and raffinate pond area has been contaminated by the former milling operations. The ground water at the disposal site was not impacted by the former milling operations at the time of the cell's construction. Activities for fiscal 1994 involve ground water sampling and site characterization of the disposal site

  16. Inter-laboratory exercise on steroid estrogens in aqueous samples

    International Nuclear Information System (INIS)

    Heath, E.; Kosjek, T.; Andersen, H.R.; Holten Luetzhoft, H.-C.; Adolfson Erici, M.; Coquery, M.; Duering, R.-A.; Gans, O.; Guignard, C.; Karlsson, P.; Manciot, F.; Moldovan, Z.; Patureau, D.; Cruceru, L.; Sacher, F.; Ledin, A.

    2010-01-01

    An inter-laboratory comparison exercise was organized among European laboratories, under the aegis of EU COST Action 636: 'Xenobiotics in Urban Water Cycle'. The objective was to evaluate the performance of testing laboratories determining 'Endocrine Disrupting Compounds' (EDC) in various aqueous matrices. As the main task three steroid estrogens: 17α-ethinylestradiol, 17β-estradiol and estrone were determined in four spiked aqueous matrices: tap water, river water and wastewater treatment plant influent and effluent using GC-MS and LC-MS/MS. Results were compared and discussed according to the analytical techniques applied, the accuracy and reproducibility of the analytical methods and the nature of the sample matrices. Overall, the results obtained in this inter-laboratory exercise reveal a high level of competence among the participating laboratories for the detection of steroid estrogens in water samples indicating that GC-MS as well as LC-MS/MS can equally be employed for the analysis of natural and synthetic hormones. - Herein are presented the results of the first international inter-laboratory study on determination of selected steroid hormones in environmental aqueous samples.

  17. Determination of thiobencarb in water samples by gas ...

    African Journals Online (AJOL)

    Homogeneous liquid-liquid microextraction via flotation assistance (HLLME-FA) coupled with gas chromatography-flame ionization detection (GC-FID) was applied for the extraction and determination of thiobencarb in water samples. In this study, a special extraction cell was designed to facilitate collection of the ...

  18. Effects of physical and chemical heterogeneity on water-quality samples obtained from wells

    Science.gov (United States)

    Reilly, Thomas E.; Gibs, Jacob

    1993-01-01

    Factors that affect the mass of chemical constituents entering a well include the distributions of flow rate and chemical concentrations along and near the screened or open section of the well. Assuming a layered porous medium (with each layer being characterized by a uniform hydraulic conductivity and chemical concentration), a knowledge of the flow from each layer along the screened zone and of the chemical concentrations in each layer enables the total mass entering the well to be determined. Analyses of hypothetical systems and a site at Galloway, NJ, provide insight into the temporal variation of water-quality data observed when withdrawing water from screened wells in heterogeneous ground-water systems.The analyses of hypothetical systems quantitatively indicate the cause-and-effect relations that cause temporal variability in water samples obtained from wells. Chemical constituents that have relatively uniform concentrations with depth may not show variations in concentrations in the water discharged from a well after the well is purged (evacuation of standing water in the well casing). However, chemical constituents that do not have uniform concentrations near the screened interval of the well may show variations in concentrations in the well discharge water after purging because of the physics of ground-water flow in the vicinity of the screen.Water-quality samples were obtained through time over a 30 minute period from a site at Galloway, NJ. The water samples were analyzed for aromatic hydrocarbons, and the data for benzene, toluene, and meta+para xylene were evaluated for temporal variations. Samples were taken from seven discrete zones, and the flow-weighted concentrations of benzene, toluene, and meta+para xylene all indicate an increase in concentration over time during pumping. These observed trends in time were reproduced numerically based on the estimated concentration distribution in the aquifer and the flow rates from each zone.The results of

  19. Sampling and Analysis Plan for the 105-N Basin Water

    International Nuclear Information System (INIS)

    R.O. Mahood

    1997-01-01

    This sampling and analysis plan defines the strategy, and field and laboratory methods that will be used to characterize 105-N Basin water. The water will be shipped to the 200 Area Effluent Treatment Facility for treatment and disposal as part of N Reactor deactivation. These analyses are necessary to ensure that the water will meet the acceptance criteria of the ETF, as established in the Memorandum of Understanding for storage and treatment of water from N-Basin (Appendix A), and the characterization requirements for 100-N Area water provided in a letter from ETF personnel (Appendix B)

  20. 222Rn in water: A comparison of two sample collection methods and two sample transport methods, and the determination of temporal variation in North Carolina ground water

    International Nuclear Information System (INIS)

    Hightower, J.H. III

    1994-01-01

    Objectives of this field experiment were: (1) determine whether there was a statistically significant difference between the radon concentrations of samples collected by EPA's standard method, using a syringe, and an alternative, slow-flow method; (2) determine whether there was a statistically significant difference between the measured radon concentrations of samples mailed vs samples not mailed; and (3) determine whether there was a temporal variation of water radon concentration over a 7-month period. The field experiment was conducted at 9 sites, 5 private wells, and 4 public wells, at various locations in North Carolina. Results showed that a syringe is not necessary for sample collection, there was generally no significant radon loss due to mailing samples, and there was statistically significant evidence of temporal variations in water radon concentrations

  1. UMTRA Project water sampling and analysis plan: Canonsburg and Burrell, Pennsylvania

    International Nuclear Information System (INIS)

    1994-03-01

    Surface remedial action was completed at the Canonsburg and Burrell UMTRA Project sites in southwestern Pennsylvania in 1985 and 1987, respectively. Results of 1993 water sampling indicate ground water flow conditions and ground water quality at both sites have remained relatively consistent with time. Uranium concentrations in ground water continue to exceed the maximum concentration limit (MCL) at the Canonsburg site; no MCLs are exceeded in ground water at the Burrell site. Surface water quality shows no evidence of impact from the sites

  2. Determination of 40K in water samples

    International Nuclear Information System (INIS)

    Delgado, C. E.; Miranda C, L.; Cuevas J, A. K.; Vega C, H. R.

    2014-10-01

    The natural water used for human consumption comes from different sources, which may contain suspended solids in varying proportions. In groundwater, the source of suspended solids is related to the dissolution of mineral strata by the waters and leaching of rocks. Also, the radioactivity could concentrate on the bodies of slow-moving water that eventually could present a risk to ecosystems, as well as for the consumer. The water usually contains several natural radionuclides as: tritium, radon, radio, uranium isotopes, etc. The objective of this study was to evaluate the concentration of 40 K in water from different areas of Zacatecas state (Mexico). Four water samples were taken in triplicate from different areas; the 40 K concentration was measured with a spectrum metric system of gamma radiation with NaI (Tl) scintillation detector of 7.62 cm. In the measuring process a standard was prepared using water and KCl analytic grade where the 40 K concentration is 6.25 mol/Lt adding 250 mg/ml of potassium. Also the system was calibrated in energy using 3 point sources of 137 Cs, diameter 22 Na and 7.62 cm of height, using containers Marinelli and 60 Co. In the obtained spectra was observed that the photon of 1.432 MeV that emits the 40 K when decaying is the most important. The highest concentration was of 123 ± 5.2 Bq/lt and the lowest was of 9 ± 0.4 Bq/lt. Under the standards of drinking water, an amount of 40 K deposits an effective dose which contributes to annual dose received by people. (Author)

  3. Sampling method of water sources at study site Taiping, Perak and Pulau Burung, Penang for research on pollutant movement in underground water

    International Nuclear Information System (INIS)

    Mohd Rifaie Mohd Murtadza; Mohd Tadza Abdul Rahman; Kamarudin Samuding; Roslanzairi Mostapa

    2005-01-01

    This paperwork explain the method of water sampling being used to take the water samples from the study sites in Taiping, Perak and Pulau Burung, Pulau Pinang. The sampling involve collecting of water samples for groundwater from boreholes and surface water from canal, river, pond, and ex-mining pond from several locations at the study sites. This study also elaborates the instruments and chemical used. The main purpose of this sampling are to obtain the important water quality parameters such as pH, conductivity, Total Dissolved Solid (TDS), heavy metals, anions, cations, and environmental isotopes delta values (d) for 18O, Deuterium dan Tritium. A correct sampling method according to standard is very important to ensure an accurate and precise results. With this, the data from the laboratory tests result can be fully utilized to make the interpretation of the pollutants movement. (Author)

  4. An opacity-sampled treatment of water vapor

    Science.gov (United States)

    Alexander, David R.; Augason, Gordon C.; Johnson, Hollis R.

    1989-01-01

    Although the bands of H2O are strong in the spectra of cool stars and calculations have repeatedly demonstrated their significance as opacity sources, only approximate opacities are currently available, due both to the difficulty of accounting for the millions of lines involved and to the inadequacy of laboratory and theoretical data. To overcome these obstacles, a new treatment is presented, based upon a statistical representation of the water vapor spectrum derived from available laboratory data. This statistical spectrum of water vapor employs an exponential distribution of line strengths and random positions of lines whose overall properties are forced to reproduce the mean opacities observed in the laboratory. The resultant data set is then treated by the opacity-sampling method exactly as are all other lines, both molecular and atomic. Significant differences are found between the results of this improved treatment and the results obtained with previous treatments of water-vapor opacity.

  5. Supplement to the UMTRA Project water sampling and analysis plan, Maybell, Colorado

    International Nuclear Information System (INIS)

    1995-09-01

    This water sampling and analysis plan (WSAP) supplement supports the regulatory and technical basis for water sampling at the Maybell, Colorado, Uranium Mill Tailings Remedial Action (UMTRA) Project site, as defined in the 1994 WSAP document for Maybell (DOE, 1994a). Further, this supplement serves to confirm our present understanding of the site relative to the hydrogeology and contaminant distribution as well as our intention to continue to use the sampling strategy as presented in the 1994 WSAP document for Maybell. Ground water and surface water monitoring activities are derived from the US Environmental Protection Agency regulations in 40 CFR Part 192 (1994) and 60 CFR 2854 (1 995). Sampling procedures are guided by the UMTRA Project standard operating procedures (JEG, n.d.), the Technical Approach Document (DOE, 1989), and the most effective technical approach for the site. Additional site-specific documents relevant to the Maybell site are the Maybell Baseline Risk Assessment (currently in progress), the Maybell Remedial Action Plan (RAP) (DOE, 1994b), and the Maybell Environmental Assessment (DOE, 1995)

  6. Delivery and fate of fluvial water and sediment to the sea: a marine geologist's view of European rivers

    Directory of Open Access Journals (Sweden)

    John D. Milliman

    2001-12-01

    resulted in increased shoreline erosion. Decreased nutrient fluxes almost certainly will affect water quality in European coastal waters, and decreased silicate delivery by some dammed rivers may result in proliferation of new (and perhaps harmful estuarine and coastal ecosystems. Everything points to further changes as European rivers and their drainage basins continue to change in the coming years.

  7. preconcentration of uranium in water samples using dispersive

    African Journals Online (AJOL)

    B. S. Chandravanshi

    Atomic Energy Organization of Iran, P.O. Box 14395-836, Tehran, Iran. 2Department of ... A new liquid phase microextraction method based on the dispersion of an extraction solvent into aqueous phase ... optical emission spectrometry, Uranium, Water samples ..... The validation of the presented procedure was performed ...

  8. Water evaporation: a transition path sampling study.

    Science.gov (United States)

    Varilly, Patrick; Chandler, David

    2013-02-07

    We use transition path sampling to study evaporation in the SPC/E model of liquid water. On the basis of thousands of evaporation trajectories, we characterize the members of the transition state ensemble (TSE), which exhibit a liquid-vapor interface with predominantly negative mean curvature at the site of evaporation. We also find that after evaporation is complete, the distributions of translational and angular momenta of the evaporated water are Maxwellian with a temperature equal to that of the liquid. To characterize the evaporation trajectories in their entirety, we find that it suffices to project them onto just two coordinates: the distance of the evaporating molecule to the instantaneous liquid-vapor interface and the velocity of the water along the average interface normal. In this projected space, we find that the TSE is well-captured by a simple model of ballistic escape from a deep potential well, with no additional barrier to evaporation beyond the cohesive strength of the liquid. Equivalently, they are consistent with a near-unity probability for a water molecule impinging upon a liquid droplet to condense. These results agree with previous simulations and with some, but not all, recent experiments.

  9. Glufosinate ammonium clean-up procedure from water samples using SPE

    Science.gov (United States)

    Tayeb M., A.; Ismail B., S.; Mardiana-Jansar, K.; Ta, Goh Choo; Agustar, Hani Kartini

    2015-09-01

    For the determination of glufosinate ammonium residue in soil and water samples, different solid phase extraction (SPE) sorbent efficiency was studied. Four different SPE sorbents i.e.: CROMABOND PS-H+, CROMABOND PS-OH-, ISOLUTE ENV+, Water Sep-Pak and OASIS HLB were used. Sample clean-up performance was evaluated using high performance liquid chromatography (Agilent 1220 infinity LC) with fluorescence detector. Detection of FMO-derivatives was done at λ ex = 260 nm and λ em= 310 nm. OASIS HLB column was the most suitable for the clean-up in view of the overall feasibility of the analysis.

  10. USDA Forest Service national protocols for sampling air pollution-sensitive waters

    Science.gov (United States)

    T. J. Sullivan

    2012-01-01

    The first step in designing a surface water sampling program is identifying one or more problems or questions that require information on water quality. Common water quality problems include nutrient enrichment (from a variety of causes), effects of atmospheric deposition (acidification, eutrophication, toxicity), and effects of major disturbances such as fire or pest...

  11. Determination of total alpha index in samples of see water by coprecipitation method

    International Nuclear Information System (INIS)

    Suarez-Navarro, J.A.; Pujol, L.; Pozuelo, M.; Pablo, A. de

    1998-01-01

    An environmental radiological monitoring network in the Spanish sea waters was set up by CEDEX in 1993. Water radioactivity is determined quarterly in eleven sampling points along the Spanish coast. The gross alpha activity is one of the parameters to be determined. The usual method for monitoring the gross alpha activity includes sample evaporation to dryness on a disk and counting using ZnS(Ag) scintillation detector. Nevertheless, the gross alpha activity determination in saline waters, such as sea waters, is troublesome, because mass attenuation is high and a very small of water is needed (0.2 ml). The coprecipitation method allows to analyze 500 ml water samples, so the detection limit is reduced and sensitivity is improved. In this work, the coprecipitation method was used to determine the gross alpha activity in the radiological network of the Spanish coast sea waters during 1996 and 1997. Gross alpha activity was very homogenous. It averaged 0.0844±0.0086 Bq.1''1 and ranged from 0.062 to 0.102 Bq.1''1. In collaboration with CIEMAT a set of samples was analyzed, they averaged 0.0689±0.0074 Bq.1''1 and ranged from 0.056 to 0.082 Bq.1''1. (Author) 5 refs

  12. Heavy water standards. Qualitative analyses, sample treating, stocking and manipulation

    International Nuclear Information System (INIS)

    Pavelescu, M.; Steflea, D.; Mihancea, I.; Varlam, M.; Irimescu, R.

    1995-01-01

    This paper presents methods and procedures for measuring heavy water concentration, and also sampling, stocking and handling of samples to be analysed. The main concentration analysis methods are: mass spectrometry, for concentrations less then 1%, densitometry, for concentrations within the range 1% - 99% and infrared spectrometry for concentrations above 99%. Procedures of sampling, processing and purification appropriate to these measuring methods were established. 1 Tab

  13. Ground-water sampling of the NNWSI (Nevada Nuclear Waste Storage Investigation) water table test wells surrounding Yucca Mountain, Nevada

    International Nuclear Information System (INIS)

    Matuska, N.A.

    1988-12-01

    The US Geological Survey (USGS), as part of the Nevada Nuclear Waste Storage Investigation (NNWSI) study of the water table in the vicinity of Yucca Mountain, completed 16 test holes on the Nevada Test Site and Bureau of Land Management-administered lands surrounding Yucca Mountain. These 16 wells are monitored by the USGS for water-level data; however, they had not been sampled for ground-water chemistry or isotropic composition. As part of the review of the proposed Yucca Mountain high-level nuclear waste repository, the Desert Research Institute (DRI) sampled six of these wells. The goal of this sampling program was to measure field-dependent parameters of the water such as electrical conductivity, pH, temperature and dissolved oxygen, and to collect samples for major and minor element chemistry and isotopic analysis. This information will be used as part of a program to geochemically model the flow direction between the volcanic tuff aquifers and the underlying regional carbonate aquifer

  14. Methods for collecting algal samples as part of the National Water-Quality Assessment Program

    Science.gov (United States)

    Porter, Stephen D.; Cuffney, Thomas F.; Gurtz, Martin E.; Meador, Michael R.

    1993-01-01

    Benthic algae (periphyton) and phytoplankton communities are characterized in the U.S. Geological Survey's National Water-Quality Assessment Program as part of an integrated physical, chemical, and biological assessment of the Nation's water quality. This multidisciplinary approach provides multiple lines of evidence for evaluating water-quality status and trends, and for refining an understanding of the factors that affect water-quality conditions locally, regionally, and nationally. Water quality can be characterized by evaluating the results of qualitative and quantitative measurements of the algal community. Qualitative periphyton samples are collected to develop of list of taxa present in the sampling reach. Quantitative periphyton samples are collected to measure algal community structure within selected habitats. These samples of benthic algal communities are collected from natural substrates, using the sampling methods that are most appropriate for the habitat conditions. Phytoplankton samples may be collected in large nonwadeable streams and rivers to meet specific program objectives. Estimates of algal biomass (chlorophyll content and ash-free dry mass) also are optional measures that may be useful for interpreting water-quality conditions. A nationally consistent approach provides guidance on site, reach, and habitat selection, as well as information on methods and equipment for qualitative and quantitative sampling. Appropriate quality-assurance and quality-control guidelines are used to maximize the ability to analyze data locally, regionally, and nationally.

  15. Monitoring of fluoride in water samples using a smartphone

    International Nuclear Information System (INIS)

    Levin, Saurabh; Krishnan, Sunderrajan; Rajkumar, Samuel; Halery, Nischal; Balkunde, Pradeep

    2016-01-01

    In several parts of India, groundwater is the only reliable, year round source for drinking water. Prevention of fluorosis, a chronic disease resulting from excess intake of fluoride, requires the screening of all groundwater sources for fluoride in endemic areas. In this paper, the authors present a field deployable colorimetric analyzer based on an inexpensive smartphone embedded with digital camera for taking photograph of the colored solution as well as an easy-fit, and compact sample chamber (Akvo Caddisfly). Phones marketed by different smartphone makers were used. Commercially available zirconium xylenol orange reagent was used for determining fluoride concentration. A software program was developed to use with the phone for recording and analyzing the RGB color of the picture. Linear range for fluoride estimation was 0–2 mg l"−"1. Around 200 samples, which consisted of laboratory prepared as well as field samples collected from different locations in Karnataka, India, were tested with Akvo Caddisfly. The results showed a significant positive correlation between Ion Selective Electrode (ISE) method and Akvo Caddisfly (Phones A, B and C), with correlation coefficient ranging between 0.9952 and 1.000. In addition, there was no significant difference in the mean fluoride content values between ISE and Phone B and C except for Phone A. Thus the smartphone method is economical and suited for groundwater fluoride analysis in the field. - Highlights: • Fluoride is an inorganic pollutant in ground water, affecting human health. • A colorimetric method for measurement of fluoride in drinking water with smartphone • Measurement is by mixing water with zirconyl xylenol orange complex reagent. • Results are comparable with laboratory-based ion selective fluoride electrode method.

  16. Monitoring of fluoride in water samples using a smartphone

    Energy Technology Data Exchange (ETDEWEB)

    Levin, Saurabh [Akvo Foundation (Netherlands); Krishnan, Sunderrajan [INREM Foundation (India); Rajkumar, Samuel; Halery, Nischal; Balkunde, Pradeep [Akvo Foundation (Netherlands)

    2016-05-01

    In several parts of India, groundwater is the only reliable, year round source for drinking water. Prevention of fluorosis, a chronic disease resulting from excess intake of fluoride, requires the screening of all groundwater sources for fluoride in endemic areas. In this paper, the authors present a field deployable colorimetric analyzer based on an inexpensive smartphone embedded with digital camera for taking photograph of the colored solution as well as an easy-fit, and compact sample chamber (Akvo Caddisfly). Phones marketed by different smartphone makers were used. Commercially available zirconium xylenol orange reagent was used for determining fluoride concentration. A software program was developed to use with the phone for recording and analyzing the RGB color of the picture. Linear range for fluoride estimation was 0–2 mg l{sup −1}. Around 200 samples, which consisted of laboratory prepared as well as field samples collected from different locations in Karnataka, India, were tested with Akvo Caddisfly. The results showed a significant positive correlation between Ion Selective Electrode (ISE) method and Akvo Caddisfly (Phones A, B and C), with correlation coefficient ranging between 0.9952 and 1.000. In addition, there was no significant difference in the mean fluoride content values between ISE and Phone B and C except for Phone A. Thus the smartphone method is economical and suited for groundwater fluoride analysis in the field. - Highlights: • Fluoride is an inorganic pollutant in ground water, affecting human health. • A colorimetric method for measurement of fluoride in drinking water with smartphone • Measurement is by mixing water with zirconyl xylenol orange complex reagent. • Results are comparable with laboratory-based ion selective fluoride electrode method.

  17. RA-226 concentration in water samples near uranium mines and in marine fishes

    International Nuclear Information System (INIS)

    Porntepkasemsan, B.

    1987-11-01

    Radium-226 and calcium were measured in water samples from the vicinity of three uranium mines and in fish samples collected from Puget sound, Washington State. The radium content of the samples were below the maximum permissible concentration 3 pCi/L for drinking water recommended by the Public Health Service and U.S. Environmental Protection Agency. The mean value of Ra-226 in water was 0.428 pCi/L and ranged from 0.043 to 1.552 pCi/L, whereas calcium content ranged from 3.0 to 190.0 mg/L. Ra-226 concentrations and calcium content in whole fish were 0.833-20.328 pCi/kg wet wt. and 114.1-259.3 mg/g ash, respectively. Results of the study indicated that Ra-226 concentration in water was correlated with calcium concentration but that this correlation was not observed in fish sample except English sole

  18. An Environmental Risk Assessment for Human-Use Trimethoprim in European Surface Waters

    Science.gov (United States)

    Straub, Jürg Oliver

    2013-01-01

    An environmental risk assessment (ERA) for the aquatic compartment in Europe from human use was developed for the old antibiotic Trimethoprim (TMP), comparing exposure and effects. The exposure assessment is based on European risk assessment default values on one hand and is refined with documented human use figures in Western Europe from IMS Health and measured removal in wastewater treatment on the other. The resulting predicted environmental concentrations (PECs) are compared with measured environmental concentrations (MECs) from Europe, based on a large dataset incorporating more than 1800 single MECs. On the effects side, available chronic ecotoxicity data from the literature were complemented by additional, new chronic results for fish and other organisms. Based on these data, chronic-based deterministic predicted no effect concentrations (PNECs) were derived as well as two different probabilistic PNEC ranges. The ERA compares surface water PECs and MECs with aquatic PNECs for TMP. Based on all the risk characterization ratios (PEC÷PNEC as well as MEC÷PNEC) and risk graphs, there is no significant risk to surface waters. PMID:27029296

  19. An Environmental Risk Assessment for Human-Use Trimethoprim in European Surface Waters

    Directory of Open Access Journals (Sweden)

    Jürg Oliver Straub

    2013-03-01

    Full Text Available An environmental risk assessment (ERA for the aquatic compartment in Europe from human use was developed for the old antibiotic Trimethoprim (TMP, comparing exposure and effects. The exposure assessment is based on European risk assessment default values on one hand and is refined with documented human use figures in Western Europe from IMS Health and measured removal in wastewater treatment on the other. The resulting predicted environmental concentrations (PECs are compared with measured environmental concentrations (MECs from Europe, based on a large dataset incorporating more than 1800 single MECs. On the effects side, available chronic ecotoxicity data from the literature were complemented by additional, new chronic results for fish and other organisms. Based on these data, chronic-based deterministic predicted no effect concentrations (PNECs were derived as well as two different probabilistic PNEC ranges. The ERA compares surface water PECs and MECs with aquatic PNECs for TMP. Based on all the risk characterization ratios (PEC÷PNEC as well as MEC÷PNEC and risk graphs, there is no significant risk to surface waters.

  20. Monitoring the aftermath of Flint drinking water contamination crisis: Another case of sampling bias?

    Science.gov (United States)

    Goovaerts, Pierre

    2017-07-15

    The delay in reporting high levels of lead in Flint drinking water, following the city's switch to the Flint River as its water supply, was partially caused by the biased selection of sampling sites away from the lead pipe network. Since Flint returned to its pre-crisis source of drinking water, the State has been monitoring water lead levels (WLL) at selected "sentinel" sites. In a first phase that lasted two months, 739 residences were sampled, most of them bi-weekly, to determine the general health of the distribution system and to track temporal changes in lead levels. During the same period, water samples were also collected through a voluntary program whereby concerned citizens received free testing kits and conducted sampling on their own. State officials relied on the former data to demonstrate the steady improvement in water quality. A recent analysis of data collected by voluntary sampling revealed, however, an opposite trend with lead levels increasing over time. This paper looks at potential sampling bias to explain such differences. Although houses with higher WLL were more likely to be sampled repeatedly, voluntary sampling turned out to reproduce fairly well the main characteristics (i.e. presence of lead service lines (LSL), construction year) of Flint housing stock. State-controlled sampling was less representative; e.g., sentinel sites with LSL were mostly built between 1935 and 1950 in lower poverty areas, which might hamper our ability to disentangle the effects of LSL and premise plumbing (lead fixtures and pipes present within old houses) on WLL. Also, there was no sentinel site with LSL in two of the most impoverished wards, including where the percentage of children with elevated blood lead levels tripled following the switch in water supply. Correcting for sampling bias narrowed the gap between sampling programs, yet overall temporal trends are still opposite. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Ion Chromatographic Analyses of Sea Waters, Brines and Related Samples

    OpenAIRE

    Nataša Gros

    2013-01-01

    This review focuses on the ion chromatographic methods for the analyses of natural waters with high ionic strength. At the beginning a natural diversity in ionic composition of waters is highlighted and terminology clarified. In continuation a brief overview of other review articles of potential interest is given. A review of ion chromatographic methods is organized in four sections. The first section comprises articles focused on the determination of ionic composition of water samples as com...

  2. Eco-Efficiency Actions and Firm Growth in European SMEs

    Directory of Open Access Journals (Sweden)

    Elisenda Jové-Llopis

    2018-01-01

    Full Text Available This study investigates the effects of eco-efficiency actions on firm performance in terms of sales growth in an extensive sample of 11,336 small- and medium-sized enterprises (SMEs located in 28 European countries. Our empirical results suggest that not all eco-strategies are positively related to better performance, at least not in the short term. We found that European companies using renewable energies, and recycling or designing products that are easier to maintain, repair, or reuse, perform better. Those that aim to reduce water or energy pollution, however, seemed to show a negative correlation to firm growth. Our results also indicate that high investment in eco-strategies improves firm growth, particularly in new members that joined the EU from 2004 onwards. Finally, we observed a U-shaped relationship between eco-strategies and firm growth, which indicates that a greater breadth of eco-strategies is associated with better firm performance. However, few European SMEs are able to either invest heavily or undertake multiple eco-strategies, thus leaving room for policy interventions.

  3. Light-water reactors reference system classification for the European reliability data system (ERDS)

    International Nuclear Information System (INIS)

    Melis, M.; Mancini, G.

    1982-01-01

    The reference system classification represents a basic stage in the organization of the European reliability data system (ERDS) for light-water reactors, a project actually in development at the Joint Research Centre, Ispra. This project is concerned with operational reliability data collection from the various ''national'' data banks, and centralization in a European reliability data system, so improving the significance of the resulting reliability evaluations. In the framework of the ERDS project, the reference system classification provides a LWR functional break-down and represents a plant-unique identification in the process of homogenization of event-data coming from the various ''national'' organizations. The report, after a brief description of the main objectives of the ERDS project, reviews the criteria followed in the elaboration of the reference system classification; then the detailed classification is presented. The nuclear power station is subdivided in about 180 systems. To each system a sheet is associated, containing: a comprehensive description of system-functions and boundaries; a descritpion of the plant operating mode, linked to the various system functions; a list of the main interface system; and finally, a list of the main components, including type and safety classification

  4. “Nanofiltration” Enabled by Super-Absorbent Polymer Beads for Concentrating Microorganisms in Water Samples

    Science.gov (United States)

    Xie, Xing; Bahnemann, Janina; Wang, Siwen; Yang, Yang; Hoffmann, Michael R.

    2016-01-01

    Detection and quantification of pathogens in water is critical for the protection of human health and for drinking water safety and security. When the pathogen concentrations are low, large sample volumes (several liters) are needed to achieve reliable quantitative results. However, most microbial identification methods utilize relatively small sample volumes. As a consequence, a concentration step is often required to detect pathogens in natural waters. Herein, we introduce a novel water sample concentration method based on superabsorbent polymer (SAP) beads. When SAP beads swell with water, small molecules can be sorbed within the beads, but larger particles are excluded and, thus, concentrated in the residual non-sorbed water. To illustrate this approach, millimeter-sized poly(acrylamide-co-itaconic acid) (P(AM-co-IA)) beads are synthesized and successfully applied to concentrate water samples containing two model microorganisms: Escherichia coli and bacteriophage MS2. Experimental results indicate that the size of the water channel within water swollen P(AM-co-IA) hydrogel beads is on the order of several nanometers. The millimeter size coupled with a negative surface charge of the beads are shown to be critical in order to achieve high levels of concentration. This new concentration procedure is very fast, effective, scalable, and low-cost with no need for complex instrumentation. PMID:26876979

  5. 222Rn determination in water and brine samples using liquid scintillation spectrometry

    International Nuclear Information System (INIS)

    Oliveira, Thiago C.; Oliveira, Arno H.

    2017-01-01

    Liquid scintillation spectrometry (LSC) is the most common technique used for 222 Rn determination in environmental aqueous sample. In this study, the performance of water-miscible (Ultima Gold AB) and immiscible (Optiscint) liquid scintillation cocktails has been compared for different matrices. 241 Am, 90 Sr and 226 Ra standard solutions were used for LSC calibration. 214 Po region was defined as better for both cocktails. Counting efficiency of 76 % and optimum PSA level of 95 for Ultima Gold AB cocktail, and counting efficiency of 82 % and optimum PSA level of 85 for Optiscint cocktail were obtained. Both cocktails showed similar results when applied for 222 Rn activity determination in water and brine samples. However the Optiscint is recommended due to its quenching resistance. Limit of detection of 0.08 and 0.06 Bq l -1 were obtained for water samples using a sample:cocktail ratio of 10:12 mL for Ultima Gold AB and Optiscint cocktails, respectively. Limit of detection of 0.08 and 0.04 Bq l -1 were obtained for brine samples using a sample:cocktail ratio of 8:12 mL for Ultima Gold AB and Optiscint cocktails, respectively. (author)

  6. Propagation of errors from a null balance terahertz reflectometer to a sample's relative water content

    International Nuclear Information System (INIS)

    Hadjiloucas, S; Walker, G C; Bowen, J W; Zafiropoulos, A

    2009-01-01

    The THz water content index of a sample is defined and advantages in using such metric in estimating a sample's relative water content are discussed. The errors from reflectance measurements performed at two different THz frequencies using a quasi-optical null-balance reflectometer are propagated to the errors in estimating the sample water content index.

  7. Measurement of extremely (2) H-enriched water samples by laser spectrometry: application to batch electrolytic concentration of environmental tritium samples.

    Science.gov (United States)

    Wassenaar, L I; Kumar, B; Douence, C; Belachew, D L; Aggarwal, P K

    2016-02-15

    Natural water samples artificially or experimentally enriched in deuterium ((2) H) at concentrations up to 10,000 ppm are required for various medical, environmental and hydrological tracer applications, but are difficult to measure using conventional stable isotope ratio mass spectrometry. Here we demonstrate that off-axis integrated cavity output (OA-ICOS) laser spectrometry, along with (2) H-enriched laboratory calibration standards and appropriate analysis templates, allows for low-cost, fast, and accurate determinations of water samples having δ(2) HVSMOW-SLAP values up to at least 57,000 ‰ (~9000 ppm) at a processing rate of 60 samples per day. As one practical application, extremely (2) H-enriched samples were measured by laser spectrometry and compared to the traditional (3) H Spike-Proxy method in order to determine tritium enrichment factors in the batch electrolysis of environmental waters. Highly (2) H-enriched samples were taken from different sets of electrolytically concentrated standards and low-level (tritium samples, and all cases returned accurate and precise initial low-level (3) H results. The ability to quickly and accurately measure extremely (2) H-enriched waters by laser spectrometry will facilitate the use of deuterium as a tracer in numerous environmental and other applications. For low-level tritium operations, this new analytical ability facilitated a 10-20 % increase in sample productivity through the elimination of spike standards and gravimetrics, and provides immediate feedback on electrolytic enrichment cell performance. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  8. Design, analysis, and interpretation of field quality-control data for water-sampling projects

    Science.gov (United States)

    Mueller, David K.; Schertz, Terry L.; Martin, Jeffrey D.; Sandstrom, Mark W.

    2015-01-01

    The process of obtaining and analyzing water samples from the environment includes a number of steps that can affect the reported result. The equipment used to collect and filter samples, the bottles used for specific subsamples, any added preservatives, sample storage in the field, and shipment to the laboratory have the potential to affect how accurately samples represent the environment from which they were collected. During the early 1990s, the U.S. Geological Survey implemented policies to include the routine collection of quality-control samples in order to evaluate these effects and to ensure that water-quality data were adequately representing environmental conditions. Since that time, the U.S. Geological Survey Office of Water Quality has provided training in how to design effective field quality-control sampling programs and how to evaluate the resultant quality-control data. This report documents that training material and provides a reference for methods used to analyze quality-control data.

  9. Hexagonal ice in pure water and biological NMR samples

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, Thomas; Gath, Julia; Hunkeler, Andreas; Ernst, Matthias, E-mail: maer@ethz.ch [ETH Zurich, Physical Chemistry (Switzerland); Böckmann, Anja, E-mail: a.bockmann@ibcp.fr [UMR 5086 CNRS, Université de Lyon 1, Institut de Biologie et Chimie des Protéines (France); Meier, Beat H., E-mail: beme@ethz.ch [ETH Zurich, Physical Chemistry (Switzerland)

    2017-01-15

    Ice, in addition to “liquid” water and protein, is an important component of protein samples for NMR spectroscopy at subfreezing temperatures but it has rarely been observed spectroscopically in this context. We characterize its spectroscopic behavior in the temperature range from 100 to 273 K, and find that it behaves like pure water ice. The interference of magic-angle spinning (MAS) as well as rf multiple-pulse sequences with Bjerrum-defect motion greatly influences the ice spectra.

  10. Supplement to the UMTRA Project water sampling and analysis plan, Monument Valley, Arizona

    International Nuclear Information System (INIS)

    1995-09-01

    This water sampling and analysis plan (WSAP) supplement supports the regulatory and technical basis for water sampling at the Riverton, Wyoming, Uranium Mill Tailings Remedial Action (UMTRA) Project site, as defined in the 1994 WSAP document for Riverton (DOE, 1994). Further, the supplement serves to confirm the Project's present understanding of the site relative to the hydrogeology and contaminant distribution as well as the intent to continue to use the sampling strategy as presented in the 1994 WSAP document for Riverton. Ground water and surface water monitoring activities are derived from the US Environmental Protection Agency regulations in 40 CFR Part 192 and 60 FR 2854. Sampling procedures are guided by the UMTRA Project standard operating procedures (JEG, n.d.), the Technical Approach Document (DOE, 1989), and the most effective technical approach for the site. Additional site-specific documents relevant to the Riverton site are the Riverton Baseline Risk Assessment (BLRA) (DOE, 1995a) and the Riverton Site Observational Work Plan (SOWP) (DOE, 1995b)

  11. Research on How to Remove Efficiently the Condensate Water of Sampling System

    International Nuclear Information System (INIS)

    Cho, SungHwan; Kim, MinSoo; Choi, HoYoung; In, WonHo

    2015-01-01

    Corrosion was caused in the measurement chamber inside the O 2 and H 2 analyzer, and thus measuring the concentration of O 2 and H 2 was not possible. It was confirmed that the cause of the occurrence of condensate water is due to the temperature difference caused during the process of the internal gas of the disposal and degasifier tank being brought into the analyzer. Thus, a heating system was installed inside and outside of the sampling panel for gas to remove generated condensate water in the analyzer and pipe. For the case where condensate water is not removed by the heating system, drain port is also installed in the sampling panel for gas to collect the condensate water of the sampling system. It was verified that there is a great volume of condensate water existing in the pipe line during the purging process after installing manufactured goods. The condensate water was fully removed by the installed heating cable and drain port. The heating cable was operated constantly at a temperature of 80 to 90 .deg. C, which allows the precise measurement of gas concentration and longer maintenance duration by blocking of the condensate water before being produced. To install instruments for measuring the gas, such as an O 2 and H 2 analyzer etc., consideration regarding whether there condensate water is present due to the temperature difference between the measuring system and analyzer is required

  12. Research on How to Remove Efficiently the Condensate Water of Sampling System

    Energy Technology Data Exchange (ETDEWEB)

    Cho, SungHwan; Kim, MinSoo; Choi, HoYoung; In, WonHo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    Corrosion was caused in the measurement chamber inside the O{sub 2} and H{sub 2} analyzer, and thus measuring the concentration of O{sub 2} and H{sub 2} was not possible. It was confirmed that the cause of the occurrence of condensate water is due to the temperature difference caused during the process of the internal gas of the disposal and degasifier tank being brought into the analyzer. Thus, a heating system was installed inside and outside of the sampling panel for gas to remove generated condensate water in the analyzer and pipe. For the case where condensate water is not removed by the heating system, drain port is also installed in the sampling panel for gas to collect the condensate water of the sampling system. It was verified that there is a great volume of condensate water existing in the pipe line during the purging process after installing manufactured goods. The condensate water was fully removed by the installed heating cable and drain port. The heating cable was operated constantly at a temperature of 80 to 90 .deg. C, which allows the precise measurement of gas concentration and longer maintenance duration by blocking of the condensate water before being produced. To install instruments for measuring the gas, such as an O{sub 2} and H{sub 2} analyzer etc., consideration regarding whether there condensate water is present due to the temperature difference between the measuring system and analyzer is required.

  13. Tritium concentrations in environmental water and food samples collected around the vicinity of the PNPP-1

    International Nuclear Information System (INIS)

    Garcia, T.Y.; Enriquez, S.O.; Duran, E.B.

    1986-01-01

    The natural radioactivity levels of tritium in environmental samples collected around the vicinity and more distant environment of the first Philippine Nuclear Power Plant (PNPP-1) in Bataan were assessed. The samples analyzed consisted of water samples such as seawater, freshwater, drinking water, groundwater and rainwater; and food samples such as cereals, vegetables, fruits; meat, milk fish and crustaceans. Tritium concentrations in water samples were determined by distillation and liquid scintillation counting techniques. The food samples were analyzed for tissue-free water tritium by the freezing-drying method followed by liquid scintillation counting techniques. (Auth.) 13 refs

  14. Water quality monitoring: A comparative case study of municipal and Curtin Sarawak's lake samples

    International Nuclear Information System (INIS)

    Kumar, A Anand; Prabakaran, K; Nagarajan, R; Jaison, J; Chan, Y S

    2016-01-01

    In this study, particle size distribution and zeta potential of the suspended particles in municipal water and lake surface water of Curtin Sarawak's lake were compared and the samples were analysed using dynamic light scattering method. High concentration of suspended particles affects the water quality as well as suppresses the aquatic photosynthetic systems. A new approach has been carried out in the current work to determine the particle size distribution and zeta potential of the suspended particles present in the water samples. The results for the lake samples showed that the particle size ranges from 180nm to 1345nm and the zeta potential values ranges from -8.58 mV to -26.1 mV. High zeta potential value was observed in the surface water samples of Curtin Sarawak's lake compared to the municipal water. The zeta potential values represent that the suspended particles are stable and chances of agglomeration is lower in lake water samples. Moreover, the effects of physico-chemical parameters on zeta potential of the water samples were also discussed. (paper)

  15. Impact of recharge through residual oil upon sampling of underlying ground water

    International Nuclear Information System (INIS)

    Wise, W.R.; Chang, Chichung; Klopp, R.A.; Bedient, P.B.

    1991-01-01

    At an aviation gasoline spill site in Traverse City, Michigan, historical records indicate a positive correlation between significant rainfall events and increased concentrations of slightly soluble organic compounds in the monitoring wells of the site. To investigate the recharge effect on ground water quality due to infiltrating water percolating past residual oil and into the saturated zone, an in situ infiltration experiment was performed at the site. Sampling cones were set at various depths below a circular test area, 13 feet (4 meters) in diameter. Rainfall was simulated by sprinkling the test area at a rate sufficiently low to prevent runoff. The sampling cones for soil-gas and ground water quality were installed in the unsaturated and saturated zones to observed the effects of the recharge process. Infiltrated water was determined to have transported organic constituents of the residual oil, specifically benzene, toluene, ethylbenzene, and ortho-xylene (BTEX), into the ground water beneath the water table, elevating the aqueous concentrations of these constituents in the saturated zone. Soil-gas concentrations of the organic compounds in the unsaturated zone increased with depth and time after the commencement of infiltration. Reaeration of the unconfined aquifer via the infiltrated water was observed. It is concluded that water quality measurements are directly coupled to recharge events for the sandy type of aquifer with an overlying oil phase, which was studied in this work. Ground water sampling strategies and data analysis need to reflect the effect of recharge from precipitation on shallow, unconfined aquifers where an oil phase may be present

  16. UMTRA project water sampling and analysis plan, Falls City, Texas. Revision 1

    International Nuclear Information System (INIS)

    1995-09-01

    Planned, routine ground water sampling activities at the US Department of Energy (DOE) Uranium Mill Tailings Remedial Action (UMTRA) Project site near Falls City, Texas, are described in this water sampling and analysis plan (WSAP). The following plan identifies and justifies the sampling locations, analytical parameters, and sampling frequency for the routine monitoring stations at the site. The ground water data are used for site characterization and risk assessment. The regulatory basis for routine ground water monitoring at UMTRA Project sites is derived from the US Environmental Protection Agency (EPA) regulations in 40 CFR Part 192. Sampling procedures are guided by the UMTRA Project standard operating procedures (SOP) (JEG, n.d.), the Technical Approach Document (TAD) (DOE, 1989), and the most effective technical approach for the site. The Falls City site is in Karnes County, Texas, approximately 8 miles [13 kilometers southwest of the town of Falls City and 46 mi (74 km) southeast of San Antonio, Texas. Before surface remedial action, the tailings site consisted of two parcels. Parcel A consisted of the mill site, one mill building, five tailings piles, and one tailings pond south of Farm-to-Market (FM) Road 1344 and west of FM 791. A sixth tailings pile designated Parcel B was north of FM 791 and east of FM 1344

  17. First Total Reflection X-Ray Fluorescence round-robin test of water samples: Preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Borgese, Laura; Bilo, Fabjola [Chemistry for Technologies Laboratory, University of Brescia, Brescia (Italy); Tsuji, Kouichi [Graduate School of Engineering, Osaka City University, Osaka (Japan); Fernández-Ruiz, Ramón [Servicio Interdepartamental de Investigación (SIdI), Laboratorio de TXRF, Universidad Autónoma de Madrid, Madrid (Spain); Margui, Eva [Department of Chemistry, University of Girona, Girona (Spain); Streli, Christina [TU Wien, Atominstitut,Radiation Physics, Vienna (Austria); Pepponi, Giancarlo [Fondazione Bruno Kessler, Povo, Trento (Italy); Stosnach, Hagen [Bruker Nano GmbH, Berlin (Germany); Yamada, Takashi [Rigaku Corporation, Takatsuki, Osaka (Japan); Vandenabeele, Peter [Department of Archaeology, Ghent University, Ghent (Belgium); Maina, David M.; Gatari, Michael [Institute of Nuclear Science and Technology, University of Nairobi, Nairobi (Kenya); Shepherd, Keith D.; Towett, Erick K. [World Agroforestry Centre (ICRAF), Nairobi (Kenya); Bennun, Leonardo [Laboratorio de Física Aplicada, Departamento de Física, Universidad de Concepción (Chile); Custo, Graciela; Vasquez, Cristina [Gerencia Química, Laboratorio B025, Centro Atómico Constituyentes, San Martín (Argentina); Depero, Laura E., E-mail: laura.depero@unibs.it [Chemistry for Technologies Laboratory, University of Brescia, Brescia (Italy)

    2014-11-01

    Total Reflection X-Ray Fluorescence (TXRF) is a mature technique to evaluate quantitatively the elemental composition of liquid samples deposited on clean and well polished reflectors. In this paper the results of the first worldwide TXRF round-robin test of water samples, involving 18 laboratories in 10 countries are presented and discussed. The test was performed within the framework of the VAMAS project, interlaboratory comparison of TXRF spectroscopy for environmental analysis, whose aim is to develop guidelines and a standard methodology for biological and environmental analysis by means of the TXRF analytical technique. - Highlights: • The discussion of the first worldwide TXRF round-robin test of water samples (18 laboratories of 10 countries) is reported. • Drinking, waste, and desalinated water samples were tested. • Data dispersion sources were identified: sample concentration, preparation, fitting procedure, and quantification. • The protocol for TXRF analysis of drinking water is proposed.

  18. Lazy ecologist’s guide to water beetle diversity: Which sampling methods are the best?

    Czech Academy of Sciences Publication Activity Database

    Klečka, Jan; Boukal S., David

    2011-01-01

    Roč. 11, č. 2 (2011), s. 500-508 ISSN 1470-160X Grant - others:EU Marie Curie European Reintegration Grant "AquaMod"(CZ) PERG04-GA-2008-239543 Institutional research plan: CEZ:AV0Z50070508 Keywords : aquatic insect * sampling methods * rarefaction Subject RIV: EH - Ecology, Behaviour Impact factor: 2.695, year: 2011

  19. Ionizing radiation as optimization method for aluminum detection from drinking water samples

    International Nuclear Information System (INIS)

    Bazante-Yamguish, Renata; Geraldo, Aurea Beatriz C.; Moura, Eduardo; Manzoli, Jose Eduardo

    2013-01-01

    The presence of organic compounds in water samples is often responsible for metal complexation; depending on the analytic method, the organic fraction may dissemble the evaluation of the real values of metal concentration. Pre-treatment of the samples is advised when organic compounds are interfering agents, and thus sample mineralization may be accomplished by several chemical and/or physical methods. Here, the ionizing radiation was used as an advanced oxidation process (AOP), for sample pre-treatment before the analytic determination of total and dissolved aluminum by ICP-OES in drinking water samples from wells and spring source located at Billings dam region. Before irradiation, the spring source and wells' samples showed aluminum levels of 0.020 mg/l and 0.2 mg/l respectively; after irradiation, both samples showed a 8-fold increase of aluminum concentration. These results are discussed considering other physical and chemical parameters and peculiarities of sample sources. (author)

  20. Fluoroquinolone antibiotics in environmental waters: sample preparation and determination.

    Science.gov (United States)

    Speltini, Andrea; Sturini, Michela; Maraschi, Federica; Profumo, Antonella

    2010-04-01

    The aim of this review is to provide a general overview on the analytical methods proposed in the last decade for trace fluoroquinolone (FQ) determination in environmental waters. A large number of studies have been developed on this topic in reason of the importance of their monitoring in the studies of environmental mobility and potential degradation pathways. Every step of the analysis has been carefully considered, with a particular attention to sample preparation, in relationship with the problems involved in the analysis of real matrices. The different strategies to minimise interference from organic matter and to achieve optimal sensitivity, especially important in those samples with lower FQ concentrations, were also highlighted. Results and progress in this field have been described and critically commented. Moreover, a worldwide overview on the presence of FQs in the environmental waters has been reported.

  1. Determination of rare earth elements in natural water samples – A review of sample separation, preconcentration and direct methodologies

    Energy Technology Data Exchange (ETDEWEB)

    Fisher, Andrew, E-mail: afisher@plymouth.ac.uk [School of Geography, Earth and Environmental Sciences, Plymouth University, Drake Circus, Plymouth, Devon, PL4 8AA (United Kingdom); Kara, Derya [Department of Chemistry, Art and Science Faculty, Balikesir University, 10100, Balikesir (Turkey)

    2016-09-07

    This review discusses and compares the methods given for the determination of rare earth elements (REE) in natural water samples, including sea, river, lake, tap, ground and waste waters as well as Antarctic ice. Since REE are at very low concentrations in natural waters, numerous different preconcentration methods have been proposed to enable their measurement. These include liquid liquid extraction, dispersive liquid-liquid micro-extraction and solidified floating drop micro-extraction. In addition to liquid-liquid extraction methods, solid phase extraction using commercial resins, resins made in-house, silica-based exchange materials and other solid media is also discussed. These and other techniques such as precipitation/co-precipitation and flotation are compared in terms of speed, preconcentration factors achieved, precision, accuracy and limits of detection (LOD). Some papers have discussed the direct determination of REE in these sample types. Some have used specialised sample introduction systems such as ultrasonic nebulization whereas others have used a standard sample introduction system coupled with inductively coupled plasma mass spectrometry (ICP-MS) detection. These direct methods have also been discussed and compared. - Highlights: • The determination of rare earth elements in waters is reviewed. • Assorted preconcentration techniques are discussed and evaluated. • Detection techniques include atomic spectrometry, potentiometry and spectrophotometry. • Special nebulisers and electrothermal vaporization approaches are reviewed.

  2. Fast and effective determination of strontium-90 in high volumes water samples

    International Nuclear Information System (INIS)

    Basarabova, B.; Dulanska, S.

    2014-01-01

    A simple and fast method was developed for determination of 90 Sr in high volumes of water samples from vicinity of nuclear power facilities. Samples were taken from the environment near Nuclear Power Plants in Jaslovske Bohunice and Mochovce in Slovakia. For determination of 90 Sr was used solid phase extraction using commercial sorbent Analig R Sr-01 from company IBC Advanced Technologies, Inc.. Determination of 90 Sr was performed with dilute solution of HNO 3 (1.5-2 M) and also tested in base medium with NaOH. For elution of 90 Sr was used eluent EDTA with pH in range 8-9. To achieve fast determination, automation was applied, which brings significant reduction of separation time. Concentration of water samples with evaporation was not necessary. Separation was performed immediately after filtration of analyzed samples. The aim of this study was development of less expensive, time unlimited and energy saving method for determination of 90 Sr in comparison with conventional methods. Separation time for fast-flow with volume of 10 dm 3 of water samples was 3.5 hours (flow-rate approximately 3.2 dm 3 / 1 hour). Radiochemical strontium yield was traced by using radionuclide 85 Sr. Samples were measured with HPGe detector (High-purity Germanium detector) at energy E φ = 514 keV. By using Analig R Sr-01 yields in range 72 - 96 % were achieved. Separation based on solid phase extraction using Analig R Sr-01 employing utilization of automation offers new, fast and effective method for determination of 90 Sr in water matrix. After ingrowth of yttrium samples were measured by Liquid Scintillation Spectrometer Packard Tricarb 2900 TR with software Quanta Smart. (authors)

  3. Determination of Sr-90 in rain water samples

    International Nuclear Information System (INIS)

    Lima, M.F.; Cunha, I.I.L.

    1988-01-01

    A work that aim is to establish radiochemical method for the determination of Sr-90 in rain water samples has been studied, as a step in an environmental monitoring program of radioactive elements. The analysis includes the preconcentration of strontium diluted in a large volume sample by precipitation of strontium as carbonate, separation of strontium from interfering elements (calcium, barium and rare earths), separation of strontium from ytrium, precipitation of purified strontium and ytrium respectively as carbonate and oxalate, and counting of Sr-90 and Y-90 activities in a low background anticoincidence beta counter. (author) [pt

  4. The Asian decapod Hemigrapsus penicillatus (de Haan, 1835) (Grapsidae, Decapoda) introduced in European waters: status quo and future perspectives

    OpenAIRE

    Gollasch, Stephan

    1999-01-01

    The Asian decapod Hemigrapsus penicillatus (de Haan, 1835) was first recorded in European waters in 1994. The first specimens were collected in the estuary of Charente Maritime on the west coast of France close to La Rochelle. The current range in Europe covers Spanish shallow water habitats of the Bay of Biscay to areas north of La Rochelle (France). Densities of up to 20 specimens per square metre occur. This species has a high temperature and salinity tolerace and will expand its distribut...

  5. Inter-laboratory exercise on steroid estrogens in aqueous samples

    Energy Technology Data Exchange (ETDEWEB)

    Heath, E., E-mail: ester.heath@ijs.s [Department of Environmental Sciences, Jozef Stefan Institute, Jamova 39, 1000 Ljubljana (Slovenia); Kosjek, T. [Department of Environmental Sciences, Jozef Stefan Institute, Jamova 39, 1000 Ljubljana (Slovenia); Andersen, H.R.; Holten Luetzhoft, H.-C. [Department of Environmental Engineering, Technical University of Denmark, Miljoevej 113, DK-2800 Kgs. Lyngby (Denmark); Adolfson Erici, M. [Stockholm University, ITM SE-106 91 Stockholm (Sweden); Coquery, M. [Cemagref, U.R. QELY, F-69336 Lyon (France); Duering, R.-A. [Giessen University, Institute of Soil Science and Soil Conservation, Giessen (Germany); Gans, O. [Umweltbundesamt GmbH, Unit Organic Analysis, Spittelauer Laende 5, 1090 Vienna (Austria); Guignard, C. [CRP Gabriel Lippmann, EVA, 41 rue du Brill, L-4422 Belvaux (Luxembourg); Karlsson, P. [Lantmannen Analycen AB, Research and Development, Sjoehagsgatan 3 Box 905, 5319, Lidkoeping (Sweden); Manciot, F. [CAE VEOLIA ENVIRONMENT, 1 Place de Turenne, 94417 Saint Maurice Cedex (France); Moldovan, Z. [National Institute of Research and Development for Isotopic and Molecular Technology, Mass Spectrometry Department, Str. Donath 65-103, 400293 Cluj-Napoca (Romania); Patureau, D. [INRA, UR50, Laboratoire de Biotechnologie de l' Environnemet (LBE), Avenue des etangs, F-11100 Narbonne (France); Cruceru, L. [Pollution Control Department, National Research Institute for Industrial Ecology (ECOIND), Sos.Panduri 90-92, sector 5, Bucharest (Romania); Sacher, F. [DVGW-Technologiezentrum Wasser, Karlsruher Strasse 84, 76139 Karlsruhe (Germany); Ledin, A. [Department of Environmental Engineering, Technical University of Denmark, Miljoevej 113, DK-2800 Kgs. Lyngby (Denmark)

    2010-03-15

    An inter-laboratory comparison exercise was organized among European laboratories, under the aegis of EU COST Action 636: 'Xenobiotics in Urban Water Cycle'. The objective was to evaluate the performance of testing laboratories determining 'Endocrine Disrupting Compounds' (EDC) in various aqueous matrices. As the main task three steroid estrogens: 17alpha-ethinylestradiol, 17beta-estradiol and estrone were determined in four spiked aqueous matrices: tap water, river water and wastewater treatment plant influent and effluent using GC-MS and LC-MS/MS. Results were compared and discussed according to the analytical techniques applied, the accuracy and reproducibility of the analytical methods and the nature of the sample matrices. Overall, the results obtained in this inter-laboratory exercise reveal a high level of competence among the participating laboratories for the detection of steroid estrogens in water samples indicating that GC-MS as well as LC-MS/MS can equally be employed for the analysis of natural and synthetic hormones. - Herein are presented the results of the first international inter-laboratory study on determination of selected steroid hormones in environmental aqueous samples.

  6. A simplified method for low-level tritium measurement in the environmental water samples

    International Nuclear Information System (INIS)

    Sakuma, Yoichi; Yamanishi, Hirokuni; Ogata, Yoshimune

    2004-01-01

    Low level liquid scintillation counting took much time with a lot of doing to distill off the impurities in the sample water before mixing the sample with the liquid scintillation cocktail. In the light of it, we investigated the possibility of an alternative filtration method for sample purification. The tritium concentration in the environmental water has become very low, and the samples have to be treated by electrolysis enrichment with a liquid scintillation analyzer. Using the solid polymer electrolyte enriching device, there is no need to add neither any electrolyte nor the neutralization after the concentration. If we could replace the distillation process with the filtration, the procedure would be simplified very much. We investigated the procedure and we were able to prove that the reverse osmosis (RO) filtration was available. Moreover, in order to rationalize all through the measurement method, we examined the followings: (1) Improvement of the enriching apparatus. (2) Easier measurement of heavy water concentration using a density meter, instead of a mass spectrometer. The concentration of water samples was measured to determine the enrichment rate of tritium during the electrolysis enrichment. (author)

  7. Efficient sample preparation method based on solvent-assisted dispersive solid-phase extraction for the trace detection of butachlor in urine and waste water samples.

    Science.gov (United States)

    Aladaghlo, Zolfaghar; Fakhari, Alireza; Behbahani, Mohammad

    2016-10-01

    In this work, an efficient sample preparation method termed solvent-assisted dispersive solid-phase extraction was applied. The used sample preparation method was based on the dispersion of the sorbent (benzophenone) into the aqueous sample to maximize the interaction surface. In this approach, the dispersion of the sorbent at a very low milligram level was achieved by inserting a solution of the sorbent and disperser solvent into the aqueous sample. The cloudy solution created from the dispersion of the sorbent in the bulk aqueous sample. After pre-concentration of the butachlor, the cloudy solution was centrifuged and butachlor in the sediment phase dissolved in ethanol and determined by gas chromatography with flame ionization detection. Under the optimized conditions (solution pH = 7.0, sorbent: benzophenone, 2%, disperser solvent: ethanol, 500 μL, centrifuged at 4000 rpm for 3 min), the method detection limit for butachlor was 2, 3 and 3 μg/L for distilled water, waste water, and urine sample, respectively. Furthermore, the preconcentration factor was 198.8, 175.0, and 174.2 in distilled water, waste water, and urine sample, respectively. Solvent-assisted dispersive solid-phase extraction was successfully used for the trace monitoring of butachlor in urine and waste water samples. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  8. Parasites as biological tags in marine fisheries research: European Atlantic waters.

    Science.gov (United States)

    Mackenzie, K; Hemmingsen, W

    2015-01-01

    Studies of the use of parasites as biological tags for stock identification and to follow migrations of marine fish, mammals and invertebrates in European Atlantic waters are critically reviewed and evaluated. The region covered includes the North, Baltic, Barents and White Seas plus Icelandic waters, but excludes the Mediterranean and Black Seas. Each fish species or ecological group of species is treated separately. More parasite tag studies have been carried out on Atlantic herring Clupea harengus than on any other species, while cod Gadus morhua have also been the subject of many studies. Other species that have been the subjects of more than one study are: blue whiting Micromesistius poutassou, whiting Merlangius merlangus, haddock Melanogrammus aeglefinus, Norway pout Trisopterus esmarkii, horse mackerel Trachurus trachurus and mackerel Scomber scombrus. Other species are dealt with under the general headings redfishes, flatfish, tunas, anadromous fish, elasmobranchs, marine mammals and invertebrates. A final section highlights how parasites can be, and have been, misused as biological tags, and how this can be avoided. It also reviews recent developments in methodology and parasite genetics, considers the potential effects of climate change on the distributions of both hosts and parasites, and suggests host-parasite systems that should reward further research.

  9. Report on water quality, sediment and water chemistry data for water and sediment samples collected from source areas to Melton Hill and Watts Bar reservoirs

    International Nuclear Information System (INIS)

    Tomaszewski, T.M.; Bruggink, D.J.; Nunn, D.L.

    1995-01-01

    Contamination of surface water and sediments in the Clinch River and Watts Bar Reservoir (CR/WBR) system as a result of past and present activities by the US Department of Energy (DOE) on the Oak Ridge Reservation (ORR) and also activities by non-ORR facilities are being studied by the Clinch River Environmental Restoration Program (CR-ERP). Previous studies have documented the presence of heavy metals, organics, and radionuclides in the sediments of reservoirs in the vicinity. In support of the CR-ERP, during the summer of 1991, TVA collected and evaluated water and sediment samples from swimming areas and municipal water intakes on Watts Bar Reservoir, Melton Hill Reservoir and Norris Reservoir, which was considered a source of less-contaminated reference or background data. Despite the numerous studies, until the current work documented by this report, relatively few sediment or water samples had been collected by the CR-ERP in the immediate vicinity of contaminant point sources. This work focused on water and sediment samples taken from points immediately downstream from suspected effluent point sources both on and off the ORR. In August and September, 1994, TVA sampled surface water and sediment at twelve locations in melton Hill and Watts Bar Reservoirs

  10. Filtration recovery of extracellular DNA from environmental water samples

    Science.gov (United States)

    qPCR methods are able to analyze DNA from microbes within hours of collecting water samples, providing the promptest notification and public awareness possible when unsafe pathogenic levels are reached. Health risk, however, may be overestimated by the presence of extracellular ...

  11. [Detecting Thallium in Water Samples using Dispersive Liquid Phase Microextraction-Graphite Furnace Atomic Absorption Spectroscopy].

    Science.gov (United States)

    Zhu, Jing; Li, Yan; Zheng, Bo; Tang, Wei; Chen, Xiao; Zou, Xiao-li

    2015-11-01

    To develope a method of solvent demulsification dispersive liquid phase microextraction (SD-DLPME) based on ion association reaction coupled with graphite furnace atomic absorption spectroscopy (GFAAS) for detecting thallium in water samples. Methods Thallium ion in water samples was oxidized to Tl(III) with bromine water, which reacted with Cl- to form TlCl4-. The ionic associated compound with trioctylamine was obtained and extracted. DLPME was completed with ethanol as dispersive solvent. The separation of aqueous and organic phase was achieved by injecting into demulsification solvent without centrifugation. The extractant was collected and injected into GFAAS for analysis. With palladium colloid as matrix modifier, a two step drying and ashing temperature programming process was applied for high precision and sensitivity. The linear range was 0.05-2.0 microg/L, with a detection limit of 0.011 microg/L. The relative standard derivation (RSD) for detecting Tl in spiked water sample was 9.9%. The spiked recoveries of water samples ranged from 94.0% to 103.0%. The method is simple, sensitive and suitable for batch analysis of Tl in water samples.

  12. Catalogue of European earthquakes and an atlas of European seismic maps

    International Nuclear Information System (INIS)

    Van Gils, J.M.

    1988-01-01

    The Catalogue of European earthquakes and an atlas of European seismic maps has been prepared in the framework of the activities of the CEC Working Group on the safety of ligh-water reactors. Seismic hazards are considered to be an important element of possible external accidents to be taken into account in the design, construction, and operation of nuclear power plants. The report relies on the data base available, the historical as well as the present-day data. After a short historical review, actually-used intensity scales are discussed. The scale applied in European countries and the one proposed in the United States of America are compared. The different seismic maps of interest are explained and a mathematical procedure presented which allows, under certain conditions, to draw seismic maps by computer facilities

  13. Microwave-assisted headspace single-drop microextration of chlorobenzenes from water samples

    Energy Technology Data Exchange (ETDEWEB)

    Vidal, Lorena [Departamento de Quimica Analitica, Nutricion y Bromatologia, Universidad de Alicante, P.O. Box 99, E-03080 Alicante (Spain); Domini, Claudia E. [Departamento de Quimica Analitica, Nutricion y Bromatologia, Universidad de Alicante, P.O. Box 99, E-03080 Alicante (Spain); Grane, Nuria [Departamento de Quimica Analitica, Nutricion y Bromatologia, Universidad de Alicante, P.O. Box 99, E-03080 Alicante (Spain); Psillakis, Elefteria [Department of Environmental Engineering, Technical University of Crete, Polytechneioupolis, GR-73100 Chania, Crete (Greece); Canals, Antonio [Departamento de Quimica Analitica, Nutricion y Bromatologia, Universidad de Alicante, P.O. Box 99, E-03080 Alicante (Spain)]. E-mail: a.canals@ua.es

    2007-05-29

    A one-step and in-situ sample preparation method used for quantifying chlorobenzene compounds in water samples has been developed, coupling microwave and headspace single-drop microextraction (MW-HS-SDME). The chlorobenzenes in water samples were extracted directly onto an ionic liquid single-drop in headspace mode under the aid of microwave radiation. For optimization, a Plackett-Burman screening design was initially used, followed by a mixed-level factorial design. The factors considered were: drop volume, aqueous sample volume, stirring speed, ionic strength, extraction time, ionic liquid type, microwave power and length of the Y-shaped glass-tube. The optimum experimental conditions found from this statistical evaluation were: a 5 {mu}L microdrop of 1-hexyl-3-methylimidazolium hexafluorophosphate exposed for 20 min to the headspace of a 30 mL aqueous sample, irradiated by microwaves at 200 W and placed in a 50 mL spherical flask connected to a 25 cm Y-shaped glass-tube. Under the optimised experimental conditions, the response of a high performance liquid chromatographic system was found to be linear over the range studied and with correlation coefficients ranging between 0.9995 and 0.9999. The method showed a good level of repeatability, with relative standard deviations varying between 2.3 and 8.3% (n = 5). Detection limits were found in the low {mu}g L{sup -1} range varying between 0.016 and 0.039 {mu}g L{sup -1}. Overall, the performance of the proposed method demonstrated the favourable effect of microwave sample irradiation upon HS-SDME. Finally, recovery studies from different types of environmental water samples revealed that matrix had little effect upon extraction.

  14. Microwave-assisted headspace single-drop microextration of chlorobenzenes from water samples

    International Nuclear Information System (INIS)

    Vidal, Lorena; Domini, Claudia E.; Grane, Nuria; Psillakis, Elefteria; Canals, Antonio

    2007-01-01

    A one-step and in-situ sample preparation method used for quantifying chlorobenzene compounds in water samples has been developed, coupling microwave and headspace single-drop microextraction (MW-HS-SDME). The chlorobenzenes in water samples were extracted directly onto an ionic liquid single-drop in headspace mode under the aid of microwave radiation. For optimization, a Plackett-Burman screening design was initially used, followed by a mixed-level factorial design. The factors considered were: drop volume, aqueous sample volume, stirring speed, ionic strength, extraction time, ionic liquid type, microwave power and length of the Y-shaped glass-tube. The optimum experimental conditions found from this statistical evaluation were: a 5 μL microdrop of 1-hexyl-3-methylimidazolium hexafluorophosphate exposed for 20 min to the headspace of a 30 mL aqueous sample, irradiated by microwaves at 200 W and placed in a 50 mL spherical flask connected to a 25 cm Y-shaped glass-tube. Under the optimised experimental conditions, the response of a high performance liquid chromatographic system was found to be linear over the range studied and with correlation coefficients ranging between 0.9995 and 0.9999. The method showed a good level of repeatability, with relative standard deviations varying between 2.3 and 8.3% (n = 5). Detection limits were found in the low μg L -1 range varying between 0.016 and 0.039 μg L -1 . Overall, the performance of the proposed method demonstrated the favourable effect of microwave sample irradiation upon HS-SDME. Finally, recovery studies from different types of environmental water samples revealed that matrix had little effect upon extraction

  15. Method validation to determine total alpha beta emitters in water samples using LSC

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Nashawati, A.; Al-akel, B.; Saaid, S.

    2006-06-01

    In this work a method was validated to determine gross alpha and beta emitters in water samples using liquid scintillation counter. 200 ml of water from each sample were evaporated to 20 ml and 8 ml of them were mixed with 12 ml of the suitable cocktail to be measured by liquid scintillation counter Wallac Winspectral 1414. The lower detection limit by this method (LDL) was 0.33 DPM for total alpha emitters and 1.3 DPM for total beta emitters. and the reproducibility limit was (± 2.32 DPM) and (±1.41 DPM) for total alpha and beta emitters respectively, and the repeatability limit was (±2.19 DPM) and (±1.11 DPM) for total alpha and beta emitters respectively. The method is easy and fast because of the simple preparation steps and the large number of samples that can be measured at the same time. In addition, many real samples and standard samples were analyzed by the method and showed accurate results so it was concluded that the method can be used with various water samples. (author)

  16. Direct sampling of chemical weapons in water by photoionization mass spectrometry.

    Science.gov (United States)

    Syage, Jack A; Cai, Sheng-Suan; Li, Jianwei; Evans, Matthew D

    2006-05-01

    The vulnerability of water supplies to toxic contamination calls for fast and effective means for screening water samples for multiple threats. We describe the use of photoionization (PI) mass spectrometry (MS) for high-speed, high-throughput screening and molecular identification of chemical weapons (CW) threats and other hazardous compounds. The screening technology can detect a wide range of compounds at subacute concentrations with no sample preparation and a sampling cycle time of approximately 45 s. The technology was tested with CW agents VX, GA, GB, GD, GF, HD, HN1, and HN3, in addition to riot agents and precursors. All are sensitively detected and give simple PI mass spectra dominated by the parent ion. The target application of the PI MS method is as a routine, real-time early warning system for CW agents and other hazardous compounds in air and in water. In this work, we also present comprehensive measurements for water analysis and report on the system detection limits, linearity, quantitation accuracy, and false positive (FP) and false negative rates for concentrations at subacute levels. The latter data are presented in the form of receiver operating characteristic curves of the form of detection probability P(D) versus FP probability P(FP). These measurements were made using the CW surrogate compounds, DMMP, DEMP, DEEP, and DIMP. Method detection limits (3sigma) obtained using a capillary injection method yielded 1, 6, 3, and 2 ng/mL, respectively. These results were obtained using 1-microL injections of water samples without any preparation, corresponding to mass detection limits of 1, 6, 3, and 2 pg, respectively. The linear range was about 3-4 decades and the dynamic range about 4-5 decades. The relative standard deviations were generally <10% at CW subacute concentrations levels.

  17. Prevalence of Cryptosporidium and Giardia lamblia in Water Samples from Jeddah and Makkah Cities

    Directory of Open Access Journals (Sweden)

    Haytham Ahmed Zakai

    2014-01-01

    Full Text Available Water contamination by Giardia lamblia and Cryptosporidium is one of the causes of diarrhoea throughout the world.  A total of 161 and 84 samples were collected from Jeddah and Makkah cities, respectively.  Each sample was concentrated by double centrifugation and the sediment was examined as a wet smear and after staining with Trichrome and Kinyoun stains.  The results showed that 56 (35% and 1 (0.62 % samples of Jeddah were positive for the oocyst of Cryptosporidium and cyst of Giardia, whereas only 21 (25% and 2 (2.4 % samples of Makkah showed positivity for oocysts and cyst of these parasites. Overall Cryptosporidium contamination in bottled water and water from filling stations was 6.8% and 17.4%, respectively. Maximum contamination for Cryptosporidium was recorded in tap water which was 51% and 25% in Jeddah and Makkah, respectively.

  18. Absolute measurement of the isotopic ratio of a water sample with very low deuterium content

    International Nuclear Information System (INIS)

    Hagemann, R.; Nief, G.; Roth, E.

    1968-01-01

    The presence of H 3+ ions which are indistinguishable from HD + ions presents the principal difficulty encountered in the measurement of isotopic ratios of water samples with very low deuterium contents using a mass spectrometer. Thus, when the sample contains no deuterium, the mass spectrometer does not indicate zero. By producing, in situ, from the sample to be measured, water vapor with an isotopic ratio very close to zero using a small distilling column, this difficulty is overcome. This column, its operating parameters, as well as the way in which the measurements are made are described. An arrangement is employed in which the isotopic ratios can be measured with a sensitivity better than 0.01 x 10 -6 . The method is applied to the determination of the isotopic ratios of three low deuterium content water samples. The results obtained permit one to assign to the sample with the lowest deuterium content an absolute value equal to 1.71 ± 0.03 ppm. This water sample is a primary standard from which is determined the isotopic ratio of a natural water sample which serves as the laboratory standard. (author) [fr

  19. Measurement of stable isotope ratio of organic carbon in water samples

    International Nuclear Information System (INIS)

    Fujii, Toshihiro; Otsuki, Akira

    1977-01-01

    A new method for the measurement of stable isotope ratios was investigated and applied to organic carbon's isotope ratio measurements in water samples. A few river water samples from Tsuchiura city were tested. After the wet oxidation of organic carbons to carbon dioxide in a sealed ampoule, the isotope ratios were determined with the gas chromatograph-quadrupole mass spectrometer combined with a total organic carbon analyser, under the dynamic conditions. The GC-MS had been equipped with the multiple ion detector-digital integrator system. The ion intensities at m/e 44 and 45 were simultaneously measured at a switching rate of 1 ms. The measurements with carbon dioxide acquired from sodium carbonate (53 μg) gave the isotope ratios with the variation coefficient of 0.62%. However, the variation coefficients obtained from organic carbons in natural water samples were 2 to 3 times as high as that from sodium carbonate. This method is simple and rapid and may be applied to various fields especially in biology and medicine. (auth.)

  20. Supplement to the UMTRA Project water sampling and analysis plan, Mexican Hat, Utah

    International Nuclear Information System (INIS)

    1995-09-01

    This water sampling and analysis plan (WSAP) supplement supports the regulatory and technical basis for water sampling at the Mexican Hat, Utah, Uranium Mill Tailings Remedial Action (UMTRA) Project site, as defined in the 1994 WSAP document for Mexican Hat (DOE, 1994). Further, the supplement serves to confirm our present understanding of the site relative to the hydrogeology and contaminant distribution as well as our intention to continue to use the sampling strategy as presented in the 1994 WSAP document for Mexican Hat. Ground water and surface water monitoring activities are derived from the US Environmental Protection Agency regulations in 40 CFR Part 192 (1991) and 60 FR 2854 (1995). Sampling procedures are guided by the UMTRA Project standard operating procedures (JEG, n.d.), the Technical Approach Document (DOE, 1989), and the most effective technical approach for the site. Additional site-specific documents relevant to the Mexican Hat site are the Mexican Hat Long-Term Surveillance Plan (currently in progress), and the Mexican Hat Site Observational Work Plan (currently in progress)

  1. Understanding the origin and evolution of water in the Moon through lunar sample studies.

    Science.gov (United States)

    Anand, Mahesh; Tartèse, Romain; Barnes, Jessica J

    2014-09-13

    A paradigm shift has recently occurred in our knowledge and understanding of water in the lunar interior. This has transpired principally through continued analysis of returned lunar samples using modern analytical instrumentation. While these recent studies have undoubtedly measured indigenous water in lunar samples they have also highlighted our current limitations and some future challenges that need to be overcome in order to fully understand the origin, distribution and evolution of water in the lunar interior. Another exciting recent development in the field of lunar science has been the unambiguous detection of water or water ice on the surface of the Moon through instruments flown on a number of orbiting spacecraft missions. Considered together, sample-based studies and those from orbit strongly suggest that the Moon is not an anhydrous planetary body, as previously believed. New observations and measurements support the possibility of a wet lunar interior and the presence of distinct reservoirs of water on the lunar surface. Furthermore, an approach combining measurements of water abundance in lunar samples and its hydrogen isotopic composition has proved to be of vital importance to fingerprint and elucidate processes and source(s) involved in giving rise to the lunar water inventory. A number of sources are likely to have contributed to the water inventory of the Moon ranging from primordial water to meteorite-derived water ice through to the water formed during the reaction of solar wind hydrogen with the lunar soil. Perhaps two of the most striking findings from these recent studies are the revelation that at least some portions of the lunar interior are as water-rich as some Mid-Ocean Ridge Basalt source regions on Earth and that the water in the Earth and the Moon probably share a common origin. © 2014 The Author(s) Published by the Royal Society. All rights reserved.

  2. The European EUCCLID pilot study on care and complications in an unselected sample of people with type 2 diabetes in primary care

    DEFF Research Database (Denmark)

    Gorter, K.J.; Wens, J.; Khunti, K.

    2010-01-01

    indicators, UKPDS-risk engine, psychological and general well-being. RESULTS: We included 103 participants from 22 GPs in 11 countries. Central data and laboratory samples were successfully collected. Of the participants 54% were female, mean age was 66 years and mean duration of diabetes was 9.6 years......BACKGROUND: European studies on quality of diabetes care in an unselected primary care diabetes population are scarce. RESEARCH QUESTION: To test the feasibility of the set-up and logistics of a cross-sectional EUropean study on Care and Complications in patients with type 2 diabetes (T2DM......) in Primary Care (EUCCLID) in 12 European countries. METHOD: One rural and one urban practice from each country participated. The central coordinating centre randomly selected five patients from each practice. Patient characteristics were assessed including medical history, anthropometric measures, quality...

  3. Uranium in Kosovo's drinking water.

    Science.gov (United States)

    Berisha, Fatlume; Goessler, Walter

    2013-11-01

    The results of this paper are an initiation to capture the drinking water and/or groundwater elemental situation in the youngest European country, Kosovo. We aim to present a clear picture of the natural uranium concentration in drinking water and/or groundwater as it is distributed to the population of Kosovo. Nine hundred and fifty-one (951) drinking water samples were analyzed by inductively coupled plasma mass spectrometry (ICPMS). The results are the first countrywide interpretation of the uranium concentration in drinking water and/or groundwater, directly following the Kosovo war of 1999. More than 98% of the samples had uranium concentrations above 0.01 μg L(-1), which was also our limit of quantification. Concentrations up to 166 μg L(-1) were found with a mean of 5 μg L(-1) and median 1.6 μg L(-1) were found. Two point six percent (2.6%) of the analyzed samples exceeded the World Health Organization maximum acceptable concentration of 30 μg L(-1), and 44.2% of the samples exceeded the 2 μg L(-1) German maximum acceptable concentrations recommended for infant food preparations. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Natural radioactivity in various water samples and radiation dose estimations in Bolu province, Turkey.

    Science.gov (United States)

    Gorur, F Korkmaz; Camgoz, H

    2014-10-01

    The level of natural radioactivity for Bolu province of north-western Turkey was assessed in this study. There is no information about radioactivity measurement reported in water samples in the Bolu province so far. For this reason, gross α and β activities of 55 different water samples collected from tap, spring, mineral, river and lake waters in Bolu were determined. The mean activity concentrations were 68.11 mBq L(-1), 169.44 mBq L(-1) for gross α and β in tap water. For all samples the gross β activity is always higher than the gross α activity. All value of the gross α were lower than the limit value of 500 mBq L(-1) while two spring and one mineral water samples were found to have gross β activity concentrations of greater than 1000 mBq L(-1). The associated age-dependent dose from all water ingestion in Bolu was estimated. The total dose for adults had an average value exceeds the WHO recommended limit value. The risk levels from the direct ingestion of the natural radionuclides in tap and mineral water in Bolu were determinated. The mean (210)Po and (228)Ra risk the value of tap and mineral waters slightly exceeds what some consider on acceptable risk of 10(-4) or less. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Radiation hazard indices of soil and water samples in Northern Malaysian Peninsula.

    Science.gov (United States)

    Almayahi, B A; Tajuddin, A A; Jaafar, M S

    2012-11-01

    The radioactivity quantity and quality were determined in soil and water samples in Northern Malaysian Peninsula (NMP) using HPGe spectroscopy and GR-135 spectrometer. The (226)Ra, (232)Th and (40)K concentrations in soil samples are 57±2, 68±4 and 427±17 Bq kg(-1), respectively, whereas in water samples were found to be 2.86±0.79, 3.78±1.73 and 152±12 Bq l(-1), respectively. These concentrations are within those reported from literature in other countries in the world. The radiological hazard indices of the samples were also calculated. The mean values obtained from soil samples are 186 Bq kg(-1), 88 nGy h(-1), 108 μSv y(-1), 0.50 and 0.65 for Radium Equivalent Activity (Ra(eq)), Absorbed Dose Rates (D(R)), Annual Effective Dose Rates (ED), External Hazard Index (H(ex)) and Internal Hazard Index (H(in)) respectively, whereas, for water samples were found to be 20, 10, 13, 0.05 and 0.06, respectively. All the health hazard indices are well below their recommended limits, except in two soil sampling sites which were found to be (*)025 (1.1 H(ex)) and (*)026 (1.1 H(ex), 1.6 H(in)). The calculated and the measured gamma dose rates had a good correlation coefficient, R=0.88. Moreover, the average value radon is 20 (in the range of 7-64) Bq m(-3), a positive correlation (R=0.81) was observed between the (222)Rn and (226)Ra concentrations in samples measured by the SNC continuous radon monitor (model 1029, Sun Nuclear Corporation) and HPGe detector, respectively. Some soils in this study with H(in) and H(ex)samples, therefore, water after processing and filtration is safe and suitable for use in household and industrial purposes. Copyright © 2012 Elsevier Ltd. All rights reserved.

  6. CERN’s Drinking Water

    CERN Multimedia

    GS Department

    CERN’s drinking water is monitored on a regular basis. A certified independent laboratory takes and analyses samples to verify that the water complies with national and European regulations for safe drinking water. Nevertheless, the system that supplies our drinking water is very old and occasionally, especially after work has been carried out on the system, the water may become cloudy or discoloured, due to traces of corrosion. For this reason, we recommend: Never use hot water from the tap for drinking or cooking. If you need hot water, then draw water from the cold water tap and heat it. Only drink or cook with cold water. Let the cold water run until it is clear before drinking or making your tea or coffee. If you have any questions about the quality of CERN’s drinking water, please contact: Jerome Espuche (GS/SEM), Serge Deleval (EN/CV) or Jonathan Gulley (DG/SCG).

  7. CERN’s Drinking Water

    CERN Multimedia

    GS Department

    2009-01-01

      CERN’s drinking water is monitored, with regular samples being taken and analysed by a certified independent laboratory, which checks on compliance with national and European regulations for safe drinking water. Nevertheless, the drinking water network is very old and occasionally, especially after work has been carried out on the network, the clarity and colour of the water can be adversely affected due to high levels of corrosion in suspension. Some basic recommendations should always be followed:   Never use hot water from the tap for drinking or cooking. If you need hot water, then draw water from the cold water tap before heating it. Only drink or cook with cold water. Let the cold water run until you notice that the water has become clear.   If you have questions about the quality of CERN’s drinking water, then please contact: Jerome Espuche (GS/SEM), Serge Deleval (EN/CV) or Jonathan Gulley (DG/SCG).

  8. CERN’s Drinking Water

    CERN Multimedia

    GS Department

      CERN’s drinking water is monitored, with regular samples being taken and analysed by a certified independent laboratory, which checks on compliance with national and European regulations for safe drinking water. Nevertheless, the drinking water network is very old and occasionally, especially after work has been carried out on the network, the clarity and colour of the water can be adversely affected due to high levels of corrosion in suspension. Some basic recommendations should always be followed: Never use hot water from the tap for drinking or cooking. If you need hot water, then draw water from the cold water tap before heating it. Only drink or cook with cold water. Let the cold water run until you notice that the water has become clear. If you have questions about the quality of CERN’s drinking water, then please contact: Jerome Espuche (GS/SEM), Serge Deleval (EN/CV) or Jonathan Gulley (DG/SCG).

  9. Development of a protocol for sampling and analysis of ballast water in Jamaica

    Directory of Open Access Journals (Sweden)

    Achsah A Mitchell

    2014-09-01

    Full Text Available The transfer of ballast by the international shipping industry has negatively impacted the environment. To design such a protocol for the area, the ballast water tanks of seven bulk cargo vessels entering a Jamaican port were sampled between January 28, 2010 and August 17, 2010. Vessels originated from five ports and used three main routes, some of which conducted ballast water exchange. Twenty-six preserved and 22 live replicate zooplankton samples were obtained. Abundance and richness were higher than at temperate ports. Exchange did not alter the biotic composition but reduced the abundance. Two of the live sample replicates, containing 31.67 and 16.75 viable individuals m-3, were non-compliant with the International Convention for the Control and Management of Ships’ Ballast Water and Sediments. Approximately 12% of the species identified in the ballast water were present in the waters nearest the port in 1995 and 11% were present in the entire bay in 2005. The protocol designed from this study can be used to aid the establishment of a ballast water management system in the Caribbean or used as a foundation for the development of further protocols.

  10. Radium 226 and lead 210 water extraction from mill tailings samples

    International Nuclear Information System (INIS)

    Fourcade, N.; Zettwoog, P.; Mery, G.

    1994-01-01

    Depositories for waste from the processing of uranium ore may release seepage waters into the environment through their impoundments. Seepage waters, when percolating through the wastes, extract radium 226. In the design or rehabilitation stage of such depositories, the exposure of critical groups of the population to radium 226 from the ground water pathway must be assessed. The same applies to lead 210. The first step is to assess the possibility of extracting the radium 226 and the lead 210 from samples of solid wastes and sludges in laboratory tests using water from the site. Extensive tests of this type were carried out in our laboratories between 1982 and 1991 on samples of mill tailings which had been collected in six installations of COGEMA and its subsidiaries. The main results are presented and analyzed. Physical, chemical and mineralogical factors influencing the leaching rates and the total quantity of water-extractable radium 226 are identified. In the case of a wet storage option, a tentative modelling of the water extraction phenomenon is proposed for the prediction of the source term both in the short term, and in the long term when all more or less soluble salts have been eliminated from the solid wastes

  11. In situ sampling of interstitial water from lake sediments

    NARCIS (Netherlands)

    Brinkman, Albertus G.; van Raaphorst, Wim; Lijklema, Lambertus

    1982-01-01

    A sampler with a relatively high resolution has been developed, which allows interstitial water to be obtained from lake sediments at well defined depths, without serious disturbance of sediment structure. Oxidation effects are excluded. Sampling time is in the order of a day. Installation requires

  12. Passive Sampling in Regulatory Chemical Monitoring of Nonpolar Organic Compounds in the Aquatic Environment

    DEFF Research Database (Denmark)

    Booij, Kees; Robinson, Craig D; Burgess, Robert M

    2016-01-01

    We reviewed compliance monitoring requirements in the European Union, the United States, and the Oslo-Paris Convention for the protection of the marine environment of the North-East Atlantic, and evaluated if these are met by passive sampling methods for nonpolar compounds. The strengths...... is the best available technology for chemical monitoring of nonpolar organic compounds. Key issues to be addressed by scientists and environmental managers are outlined....... and shortcomings of passive sampling are assessed for water, sediments, and biota. Passive water sampling is a suitable technique for measuring concentrations of freely dissolved compounds. This method yields results that are incompatible with the EU's quality standard definition in terms of total concentrations...

  13. Solid phase extraction for determination of 90Sr in water sample

    International Nuclear Information System (INIS)

    Ometakova, J.

    2009-01-01

    We studied the use of an extraction chromatography for determination of 90 Sr in samples of contaminated water. The aim of the thesis was to compare selected products from the point of view of the strontium yields and time needed. Three commercial products: 3M Empore Strontium Rad Disk, AnaLig, Sr-Resin and two classical methods: liquid-liquid extraction with tributylphosphate and carbonate co-precipitation (to eliminate interferers) were used for separation of 90 Sr. The water sample was used in radiochemical analysis for determination volume activity of 90 Sr. A radiochemical strontium yield was traced by using radionuclide 85 Sr. Samples were counted over a two week period to monitor the ingrowth of 90 Y on TRI CARB LSC counter. Samples were measured using an HPGe detector to find out 85 Sr recoveries at 514 keV line and they were counted directly by Cherenkov counting after the growth of 90 Y using TriCarb LSC counter after a two- week period (author)

  14. UMTRA project water sampling and analysis plan, Ambrosia Lake, New Mexico

    International Nuclear Information System (INIS)

    1994-02-01

    This water sampling and analysis plan (WSAP) provides the basis for ground water sampling at the Ambrosia Lake Uranium Mill Tailings Remedial Action (UMTRA) Project site during fiscal year 1994. It identifies and justifies the sampling locations, analytical parameters, detection limits, and sampling frequency for the monitoring locations and will be updated annually. The Ambrosia Lake site is in McKinley County, New Mexico, about 40 kilometers (km) (25 miles [mi]) north of Grants, New Mexico, and 1.6 km (1 mi) east of New Mexico Highway 509 (Figure 1.1). The town closest to the tailings pile is San Mateo, about 16 km ( 10 mi) southeast (Figure 1.2). The former mill and tailings pile are in Section 28, and two holding ponds are in Section 33, Township 14 North, Range 9 West. The site is shown on the US Geological Survey (USGS) map (USGS, 1980). The site is approximately 2100 meters (m) (7000 feet [ft]) above sea level

  15. Performance of a hydrostatic sampler for collecting samples at the water-sediment interface in lakes

    Directory of Open Access Journals (Sweden)

    Fernando PEDROZO

    2008-02-01

    Full Text Available The water-sediment interface plays a significant role in the determination of the trophic degree of a waterbody. Numerous redox reactions take place there, resulting in the release of contaminants from the sediments to the water column. The aim of the present work was to develop an equipment for collecting samples from the water-sediment interface. Such equipment was to have a simple design, low construction cost, no depth limitations, and high levels of personal safety and to be reliable in the collection of samples. The performance of the hydrostatic sampler thus developed was tested against samples collected either remotely with a corer or directly with syringes by autonomous divers. The hydrostatic sampler permits access to depths where the costs of the traditional diving methodology are expensive, and where working conditions are dangerous for the diver. The hydrostatic sampler provides an additional means of collecting samples from the water-sediment interface, which together with pore-water samples, facilitates the investigation and understanding of chemical mechanisms in lakes, for instance, those that control the P release from sediment to the water column.

  16. White HDPE bottles as source of serious contamination of water samples with Ba and Zn.

    Science.gov (United States)

    Reimann, Clemens; Grimstvedt, Andreas; Frengstad, Bjørn; Finne, Tor Erik

    2007-03-15

    During a recent study of surface water quality factory new white high-density polyethylene (HDPE) bottles were used for collecting the water samples. According to the established field protocol of the Geological Survey of Norway the bottles were twice carefully rinsed with water in the field prior to sampling. Several blank samples using milli-Q (ELGA) water (>18.2 MOmega) were also prepared. On checking the analytical results the blanks returned values of Ag, Ba, Sr, V, Zn and Zr. For Ba and Zn the values (c. 300 microg/l and 95 microg/l) were about 10 times above the concentrations that can be expected in natural waters. A laboratory test of the bottles demonstrated that the bottles contaminate the samples with significant amounts of Ba and Zn and some Sr. Simple acid washing of the bottles prior to use did not solve the contamination problem for Ba and Zn. The results suggest that there may exist "clean" and "dirty" HDPE bottles depending on manufacturer/production process. When collecting water samples it is mandatory to check bottles regularly as a possible source of contamination.

  17. High-frequency, long-duration water sampling in acid mine drainage studies: a short review of current methods and recent advances in automated water samplers

    Science.gov (United States)

    Chapin, Thomas

    2015-01-01

    Hand-collected grab samples are the most common water sampling method but using grab sampling to monitor temporally variable aquatic processes such as diel metal cycling or episodic events is rarely feasible or cost-effective. Currently available automated samplers are a proven, widely used technology and typically collect up to 24 samples during a deployment. However, these automated samplers are not well suited for long-term sampling in remote areas or in freezing conditions. There is a critical need for low-cost, long-duration, high-frequency water sampling technology to improve our understanding of the geochemical response to temporally variable processes. This review article will examine recent developments in automated water sampler technology and utilize selected field data from acid mine drainage studies to illustrate the utility of high-frequency, long-duration water sampling.

  18. Multielement neutron activation analysis of underground water samples

    International Nuclear Information System (INIS)

    Kusaka, Yuzuru; Tsuji, Haruo; Fujimoto, Yuzo; Ishida, Keiko; Mamuro, Tetsuo.

    1980-01-01

    An instrumental neutron activation analysis by gamma-ray spectrometry with high resolution and large volume Ge (Li) detectors followed by data processing with an electronic computer was applied to the multielemental analysis to elucidate the chemical qualities of the underground water which has been widely used in the sake brewing industries in Mikage, Uozaki and Nishinomiya districts, called as miyamizu. The evaporated residues of the water samples were subjected to the neutron irradiations in reactor for 1 min at a thermal flux of 1.5 x 10 12 n.cm -2 .sec -1 and for 30 hrs at a thermal flux of 9.3 x 10 11 n.cm -2 .sec -1 or for 5 hrs at a thermal flux of 3.9 x 10 12 n.cm -2 .sec -1 . Thus, 11 elements in the former short irradiation and 38 elements in the latter two kinds of long irradiation can be analyzed. Conventional chemical analysis including atomic absorption method and others are also applied on the same samples, and putting the all results together, some considerations concerning the geochemical meaning of the analytical values are made. (author)

  19. Determination of radiocesium in environmental water samples using copper ferro(II)cyanide and sodium tetraphenylborate

    International Nuclear Information System (INIS)

    Popov, L.; Kuleff, I.; Djingova, R.

    2006-01-01

    A procedure for the radiochemical separation and radiochemical purification of radiocesium ( 134 Cs and 137 Cs) in bulk environmental water samples is proposed. Radiocesium was removed from the water by cation-exchange with copper ferro(II)cyanide and was purified by precipitation with sodium tetraphenylborate. The influence of the concentration of potassium in the water sample on the chemical yield was investigated. The validation of the proposed method was carried out by analyzing reference materials. The application of the method was demonstrated with the determination of the concentration of radiocesium in water samples from rivers around NPP 'Kozloduy', Bulgaria, Danube and Ogosta. (author)

  20. Detection by PCR of pathogenic protozoa in raw and drinkable water samples in Colombia.

    Science.gov (United States)

    Triviño-Valencia, Jessica; Lora, Fabiana; Zuluaga, Juan David; Gomez-Marin, Jorge E

    2016-05-01

    We evaluated the presence of DNA of Giardia, Toxoplasma, and Cryptosporidium by PCR, and of Giardia and Cryptosporidium genera by immunofluorescence antibody test (IFAT), in water samples, before, during, and after plant treatment for drinkable water. We applied this method in 38 samples of 10 l of water taken from each of the water treatment steps and in 8 samples taken at home (only for Toxoplasma PCR) in Quindio region in Colombia. There were 8 positive samples for Cryptosporidium parvum (21 %), 4 for Cryptosporidium hominis (10.5 %), 27 for Toxoplasma gondii (58.6 %), 2 for Giardia duodenalis assemblage A (5.2 %), and 5 for G. duodenalis assemblage B (13.1 %). By IFAT, 23 % were positive for Giardia and 21 % for Cryptosporidium. An almost perfect agreement was found between IFAT and combined results of PCR, by Kappa composite proportion analysis. PCR positive samples were significantly more frequent in untreated raw water for C. parvum (p = 0.02). High mean of fecal coliforms, high pH values, and low mean of chlorine residuals were strongly correlated with PCR positivity for G. duodenalis assemblage B. High pH value was correlated with PCR positivity for C. parvum. Phylogenetic analysis of DNA sequences was possible, showing water and human clinical sequences for Toxoplasma within the same phylogenetic group for B1 repeated sequence. PCR assay is complementary to IFAT assay for monitoring of protozoa in raw and drinkable water, enabling species identification and to look for phylogenetic analysis in protozoa from human and environmental sources.

  1. Review of robust measurement of phosphorus in river water: sampling, storage, fractionation and sensitivity

    Directory of Open Access Journals (Sweden)

    H. P. Jarvie

    2002-01-01

    Full Text Available This paper reviews current knowledge on sampling, storage and analysis of phosphorus (P in river waters. Potential sensitivity of rivers with different physical, chemical and biological characteristics (trophic status, turbidity, flow regime, matrix chemistry is examined in terms of errors associated with sampling, sample preparation, storage, contamination, interference and analytical errors. Key issues identified include: The need to tailor analytical reagents and concentrations to take into account the characteristics of the sample matrix. The effects of matrix interference on the colorimetric analysis. The influence of variable rates of phospho-molybdenum blue colour formation. The differing responses of river waters to physical and chemical conditions of storage. The higher sensitivities of samples with low P concentrations to storage and analytical errors. Given high variability of river water characteristics in space and time, no single standardised methodology for sampling, storage and analysis of P in rivers can be offered. ‘Good Practice’ guidelines are suggested, which recommend that protocols for sampling, storage and analysis of river water for P is based on thorough site-specific method testing and assessment of P stability on storage. For wider sampling programmes at the regional/national scale where intensive site-specific method and stability testing are not feasible, ‘Precautionary Practice’ guidelines are suggested. The study highlights key areas requiring further investigation for improving methodological rigour. Keywords: phosphorus, orthophosphate, soluble reactive, particulate, colorimetry, stability, sensitivity, analytical error, storage, sampling, filtration, preservative, fractionation, digestion

  2. European attitudes to water pricing

    DEFF Research Database (Denmark)

    Jensen, Anne Kejser

    2016-01-01

    , there is a need for increased understanding of the implementation process and the attitudes towards implementation among the general public. This paper explores the spatial heterogeneity in the public attitude towards internalizing environmental and resource costs in the price of water across the EU regions....... Within an extensive spatial dataset constructed for the purpose, we estimate the effect of individual information levels and affordability concerns on the attitude towards environmental water pricing. Information about water problems is found to have a significant and positive effect on attitudes...

  3. Ion Chromatographic Analyses of Sea Waters, Brines and Related Samples

    Directory of Open Access Journals (Sweden)

    Nataša Gros

    2013-06-01

    Full Text Available This review focuses on the ion chromatographic methods for the analyses of natural waters with high ionic strength. At the beginning a natural diversity in ionic composition of waters is highlighted and terminology clarified. In continuation a brief overview of other review articles of potential interest is given. A review of ion chromatographic methods is organized in four sections. The first section comprises articles focused on the determination of ionic composition of water samples as completely as possible. The sections—Selected Anions, Selected Cations and Metals—follow. The most essential experimental conditions used in different methods are summarized in tables for a rapid comparison. Techniques encountered in the reviewed articles comprise: direct determinations of ions in untreated samples with ion- or ion-exclusion chromatography, or electrostatic ion chromatography; matrix elimination with column-switching; pre-concentration with a chelation ion chromatography and purge-and-trap pre-concentration. Different detection methods were used: non-suppressed conductometric or suppressed conductometric, direct spectrometric or spectrometric after a post-column derivetization, and inductively coupled plasma in combination with optical emission or mass spectrometry.

  4. The regulation of diffuse pollution in the European Union: science, governance and water resource management

    Directory of Open Access Journals (Sweden)

    Sarah Hendry

    2012-11-01

    Full Text Available Reducing diffuse pollution is a perpetuating problem for environmental regulators. This paper will consider novel ways to regulate its impacts on the aquatic environment, with particular reference to rural landuse. It will look at the relationship between science, policy and law, and the contributions of integrated water resources management and governance at regional, national and river basin scales. Regulatory frameworks for water in the European Union will be explored, along with their implementation nationally in Scotland and at catchment scale in the Tweed river basin. It will conclude that regulation has a role to play, but that it is necessary to take a visionary holistic and integrated approach, nesting regulation within a governance framework that involves all stakeholders and takes full account of developing science and socio-economic drivers to meet environmental objectives.

  5. Estimation of uranium in drinking water samples collected from different locations across Tarapur, India

    International Nuclear Information System (INIS)

    Dusane, C.B.; Maity, Sukanta; Sahu, S.K.; Pandit, G.G.

    2015-01-01

    In this study, drinking water samples were collected from different locations across Tarapur, India for screening uranium contents. Uranium concentrations were determined by differential pulse adsorptive stripping voltammetry (DPASV). Uranium concentration in water samples varied in a wide range from 0.6-7.9 μg L -1 . Results were compared with the international water quality guidelines World Health Organization (WHO, 2011) and were found within the permissible limit. Results were also compared with the safe limit values for drinking water recommended by national organization like Atomic Energy Regulatory Board (AERB). (author)

  6. Measurement of the tritium concentration in the fractionated distillate from environmental water samples.

    Science.gov (United States)

    Atkinson, Robert; Eddy, Teresa; Kuhne, Wendy; Jannik, Tim; Brandl, Alexander

    2014-09-01

    Standard procedures for the measurement of tritium in water samples often require distillation of an appropriate sample aliquot. This distillation process may result in a fractionation of tritiated water and regular light water due to the vapor pressure isotope effect, introducing either a bias or an additional contribution to the total tritium measurement uncertainty. The current study investigates the relative change in vapor pressure isotope effect in the course of the distillation process, distinguishing it from and extending previously published measurements. The separation factor as a quantitative measure of the vapor pressure isotope effect is found to assume values of 1.04 ± 0.036, 1.05 ± 0.026, and 1.07 ± 0.038, depending on the vigor of the boiling process during distillation of the sample. A lower heat setting in the experimental setup, and therefore a less vigorous boiling process, results in a larger value for the separation factor. For a tritium measurement in water samples where the first 5 mL are discarded, the tritium concentration could be underestimated by 4-7%. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Estimation of uranium in different types of water and sand samples by adsorptive stripping voltammetry

    International Nuclear Information System (INIS)

    Bhalke, Sunil; Raghunath, Radha; Mishra, Suchismita; Suseela, B.; Tripathi, R.M.; Pandit, G.G.; Shukla, V.K.; Puranik, V.D.

    2005-01-01

    A method is standardized for the estimation of uranium by adsorptive stripping voltammetry using chloranilic acid (CAA) as complexing agent. The optimum parameters to get best sensitivity and good reproducibility for uranium were 60s adsorption time, pH 1.8, chloranilic acid (2x10 -4 M) and 0.002M EDTA. The peak potential under this condition was found to be -0.03 V. With these optimum parameters a sensitivity of 1.19 nA/nM uranium was observed. Detection limit for this optimum parameter was found to be 0.55 nM. This can be further improved by increasing adsorption time. Using this method, uranium was estimated in different type of water samples such as seawater, synthetic seawater, stream water, tap water, well water, bore well water and process water. This method has also been used for estimation of uranium in sand, organic solvent used for extraction of uranium from phosphoric acid and its raffinate. Sample digestion procedures used for estimation of uranium in various matrices are discussed. It has been observed from the analysis that the uranium peak potentials changes with matrix of the sample, hence, standard addition method is the best method to get reliable and accurate results. Quality assurance of the standardized method is verified by analyzing certified reference water sample from USDOE, participating intercomparison exercises and also by estimating uranium content in water samples both by differential pulse adsorptive stripping voltammetric and laser fluorimetric techniques. (author)

  8. Effects of soil water saturation on sampling equilibrium and kinetics of selected polycyclic aromatic hydrocarbons.

    Science.gov (United States)

    Kim, Pil-Gon; Roh, Ji-Yeon; Hong, Yongseok; Kwon, Jung-Hwan

    2017-10-01

    Passive sampling can be applied for measuring the freely dissolved concentration of hydrophobic organic chemicals (HOCs) in soil pore water. When using passive samplers under field conditions, however, there are factors that might affect passive sampling equilibrium and kinetics, such as soil water saturation. To determine the effects of soil water saturation on passive sampling, the equilibrium and kinetics of passive sampling were evaluated by observing changes in the distribution coefficient between sampler and soil (K sampler/soil ) and the uptake rate constant (k u ) at various soil water saturations. Polydimethylsiloxane (PDMS) passive samplers were deployed into artificial soils spiked with seven selected polycyclic aromatic hydrocarbons (PAHs). In dry soil (0% water saturation), both K sampler/soil and k u values were much lower than those in wet soils likely due to the contribution of adsorption of PAHs onto soil mineral surfaces and the conformational changes in soil organic matter. For high molecular weight PAHs (chrysene, benzo[a]pyrene, and dibenzo[a,h]anthracene), both K sampler/soil and k u values increased with increasing soil water saturation, whereas they decreased with increasing soil water saturation for low molecular weight PAHs (phenanthrene, anthracene, fluoranthene, and pyrene). Changes in the sorption capacity of soil organic matter with soil water content would be the main cause of the changes in passive sampling equilibrium. Henry's law constant could explain the different behaviors in uptake kinetics of the selected PAHs. The results of this study would be helpful when passive samplers are deployed under various soil water saturations. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. A rapid and sensitive analytical method for the determination of 14 pyrethroids in water samples.

    Science.gov (United States)

    Feo, M L; Eljarrat, E; Barceló, D

    2010-04-09

    A simple, efficient and environmentally friendly analytical methodology is proposed for extracting and preconcentrating pyrethroids from water samples prior to gas chromatography-negative ion chemical ionization mass spectrometry (GC-NCI-MS) analysis. Fourteen pyrethroids were selected for this work: bifenthrin, cyfluthrin, lambda-cyhalothrin, cypermethrin, deltamethrin, esfenvalerate, fenvalerate, fenpropathrin, tau-fluvalinate, permethrin, phenothrin, resmethrin, tetramethrin and tralomethrin. The method is based on ultrasound-assisted emulsification-extraction (UAEE) of a water-immiscible solvent in an aqueous medium. Chloroform was used as extraction solvent in the UAEE technique. Target analytes were quantitatively extracted achieving an enrichment factor of 200 when 20 mL aliquot of pure water spiked with pyrethroid standards was extracted. The method was also evaluated with tap water and river water samples. Method detection limits (MDLs) ranged from 0.03 to 35.8 ng L(-1) with RSDs values or =0.998. Recovery values were in the range of 45-106%, showing satisfactory robustness of the method for analyzing pyrethroids in water samples. The proposed methodology was applied for the analysis of river water samples. Cypermethrin was detected at concentration levels ranging from 4.94 to 30.5 ng L(-1). Copyright 2010 Elsevier B.V. All rights reserved.

  10. Robowell: An automated process for monitoring ground water quality using established sampling protocols

    Science.gov (United States)

    Granato, G.E.; Smith, K.P.

    1999-01-01

    Robowell is an automated process for monitoring selected ground water quality properties and constituents by pumping a well or multilevel sampler. Robowell was developed and tested to provide a cost-effective monitoring system that meets protocols expected for manual sampling. The process uses commercially available electronics, instrumentation, and hardware, so it can be configured to monitor ground water quality using the equipment, purge protocol, and monitoring well design most appropriate for the monitoring site and the contaminants of interest. A Robowell prototype was installed on a sewage treatment plant infiltration bed that overlies a well-studied unconfined sand and gravel aquifer at the Massachusetts Military Reservation, Cape Cod, Massachusetts, during a time when two distinct plumes of constituents were released. The prototype was operated from May 10 to November 13, 1996, and quality-assurance/quality-control measurements demonstrated that the data obtained by the automated method was equivalent to data obtained by manual sampling methods using the same sampling protocols. Water level, specific conductance, pH, water temperature, dissolved oxygen, and dissolved ammonium were monitored by the prototype as the wells were purged according to U.S Geological Survey (USGS) ground water sampling protocols. Remote access to the data record, via phone modem communications, indicated the arrival of each plume over a few days and the subsequent geochemical reactions over the following weeks. Real-time availability of the monitoring record provided the information needed to initiate manual sampling efforts in response to changes in measured ground water quality, which proved the method and characterized the screened portion of the plume in detail through time. The methods and the case study described are presented to document the process for future use.

  11. The Scaling of Water Governance Tasks: A Comparative Federal Analysis of the European Union and Australia

    Science.gov (United States)

    Benson, David; Jordan, Andrew

    2010-07-01

    Conflicts over how to “scale” policy-making tasks have characterized environmental governance since time immemorial. They are particularly evident in the area of water policy and raise important questions over the democratic legitimacy, economic efficiency and effectiveness of allocating (or “scaling”) tasks to some administrative levels as opposed to others. This article adopts a comparative federalism perspective to assess the “optimality” of scaling—either upward or downward—in one issue area, namely coastal recreational water quality. It does so by comparing the scaling of recreational water quality tasks in the European Union (EU) and Australia. It reveals that the two systems have adopted rather different approaches to scaling and that this difference can partly be accounted for in federal theoretical terms. However, a much greater awareness of the inescapably political nature of scaling processes is nonetheless required. Finally, some words of caution are offered with regard to transferring policy lessons between these two jurisdictions.

  12. Analytical determination of traced elements in concrete samples used in nuclear reactors of the European Community

    International Nuclear Information System (INIS)

    May, S.; Piccot, D.

    1984-01-01

    In reactor dismantling residual radioacting of concrete used, especially in biological shield can brought problems for treatment and disposal. Radioactivity of concrete from reactors can be forecasted if element content is known. Elements producing long life radionuclides are: chlorine, calcium nickel, cobalt, niobium, europium and samarium. Neutron activation analysis is used for determination of these elements whithout chemical separation for Ca, Co, Eu and Sm and with radiochemical separation for Cl, Ni and Nb. A lot of elements, less interesting are also determined by gamma spectrometry after irradiation. It was possible to determine 29 elements in 21 concrete samples from different European Community reactors

  13. Are we Europeans?: Correlates and the relation between national and European identity

    Directory of Open Access Journals (Sweden)

    Mihić Vladimir

    2009-01-01

    Full Text Available Researches of the correlates of the national identity are plentiful both in Serbian and foreign literature. However, in the past decade or so, a new social identity starts to make its way into the researches of the social psychologists-European identity or the sense of belonging to the Europe and the Europeans. This paper deals with the relation between national and European identity, as well as with the correlates of both of these, or one of them. The sample consisted of 451 subjects, all residents of major cities in the Vojvodina region (northern Serbia, divided into several categories-ethnicity (Serbs and Hungarians, educational level (primary and secondary school or University degree, gender and age. Several scales have been used: Cinnirela's national and European identity scale, Collective self-esteem scale, scale measuring attitudes towards the European integration-STEIN and Social dominance orientation scale-SDO. The questionnaire with the demographic characteristics has also been the part of the instrument. The research has been conducted in 2005 and 2006 in the all of the major Vojvodinian cities. Results show the relation between national and European identity is foggy, but general conclusion is that we can observe them as independent identities. The correlates of the national identity were ethnicity, high social dominance orientation, high collective self-esteem and negative attitude towards the European integrations. Correlates of the European identity were fewer: ethnicity, positive attitude towards the European integration and low social dominance orientation.

  14. Presence of pesticide residues in water, sediment and biological samples taken from aquatic environments in Honduras

    International Nuclear Information System (INIS)

    Meyer, D.E.

    1999-01-01

    The objective of this study was to detect the presence of persistent pesticides in water, sediment and biological samples taken from aquatic environments in Honduras during the period 1995-98. Additionally, the LC 50 for 2 fungicides and 2 insecticides on post-larval Penaeus vannamei was determined in static water bioassays. A total of 80 water samples, 16 sediment samples and 7 biological samples (fish muscle tissue) were analyzed for detection of organochlorine and organophosphate pesticide residues. The results of sample analyses indicate a widespread contamination of Honduran continental and coastal waters with organochlorine pesticides. Most detections were of low ( 50 values and were therefore found to be much more toxic to the post-larval shrimp than the fungicides tridemorph and propiconazole. (author)

  15. EPR (European Pressurized water Reactor) The advanced nuclear reactor

    International Nuclear Information System (INIS)

    2004-01-01

    Nuclear energy, which provides a steady supply of electricity at low cost, has its rightful place in the energy mix of the 21. century, which puts the emphasis on sustainable development. The EPR is the only 3. generation reactor under construction today. It is an evolutionary reactor that represents a new generation of pressurized water reactors with no break in the technology used for the most recent models. The EPR was developed by Framatome and Siemens, whose nuclear activities were combined in January 2001 to form Framatome ANP, a subsidiary of AREVA and Siemens. EDF and the major German electricity companies played an active part in the project. The safety authorities of the two countries joined forces to bring their respective safety standards into line and draw up joint design rules for the new reactor. The project had three objectives: meet the requirements of European utilities, comply with the safety standards laid down by the French safety authority for future pressurized water reactors, in concert with its German counterpart, and make nuclear energy even more competitive than energy generated using fossil fuels. The EPR can guarantee a safe, inexpensive electricity supply, without adding to the greenhouse effect. It meets the requirements of the safety authorities and lives up to the expectations of electricity utilities. This document presents the main characteristics of the EPR, and in particular the additional measures to prevent the occurrence of events likely to damage the core, the leak-tight containment, the measures to reduce the exposure of operating and maintenance personnel, the solutions for an even greater protection of the environment. The foreseen development of the EPR in France and abroad (Finland, China, the United States) is summarized

  16. Soil and Water – What is Detectable through Microbiological Sample Preparation Techniques

    Science.gov (United States)

    The concerns of a potential terrorist’s use of biological agents in soil and ground water are articulated by comparisons to major illnesses in this Country involving contaminated drinking water sources. Objectives are focused on the importance of sample preparation in the rapid, ...

  17. Relationship of land use to water quality in the Chesapeake Bay region. [water sampling and photomapping river basins

    Science.gov (United States)

    Correll, D. L.

    1978-01-01

    Both the proportions of the various land use categories present on each watershed and the specific management practices in use in each category affect the quality of runoff waters, and the water quality of the Bay. Several permanent and portable stations on various Maryland Rivers collect volume-integrated water samples. All samples are analyzed for a series of nutrient, particulate, bacterial, herbicide, and heavy metal parameters. Each basin is mapped with respect to land use by the analysis of low-elevation aerial photos. Analyses are verified and adjusted by ground truth surveys. Data are processed and stored in the Smithsonian Institution data bank. Land use categories being investigated include forests/old fields, pastureland, row crops, residential areas, upland swamps, and tidal marshes.

  18. Determination of different contaminants in selective drinking water samples collected from Peshawar valley area

    International Nuclear Information System (INIS)

    Ihsanullah; Khan, M.; Khattak, T.N.; Sattar, A.

    1999-01-01

    Among the pollutants carried through sewage, industrial effluents, fertilizers, pesticides; heavy metals and various pathogenic bacteria are directly related to human/animal diseases. Samples of drinking water were collected from different locations, in the Peshawar area. Cadmium, lead and copper levels in these samples were determined by potentiometric stripping analysis (PSA). The data indicated wide variation in the concentration of these heavy metals. Variation in results is discussed on the basis of some possible sources of contamination. The concentration of cadmium and lead in all the samples was higher compared to the values given in the guideline of World Health Organization (WHO) for drinking water. Copper was below the detection limit in majority of the samples. The values of Cd, Pb and Cu were in the range of 0.023-2.75, 0.025-1.88 and 0-0.67 mg/1 respectively. Various physical quality indices (ph, electrical conductivity and total solids) and pathogenic bacteria (E. coli and total coliforms) were also determined in water samples. Most of the drinking waters was found contaminated with higher levels of Cd and Pb and pathogenic bacteria and hence, considered unfit for drinking purposes. (author)

  19. 137Caesium in samples of wild-grown Boletus edulis Bull. from Lucca province (Tuscany, Italy) and other Italian and European geographical areas.

    Science.gov (United States)

    Betti, Laura; Palego, Lionella; Lucacchini, Antonio; Giannaccini, Gino

    2017-01-01

    Samples of the edible mushroom Boletus edulis Bull. were studied to assess the risk for human health related to their content of the artificial radionuclide 137 Cs. Fresh B. edulis carpophores were collected in four undeveloped microhabitats of Lucca province (Tuscany, North-Central Italy). Dried non-cultivated samples coming from this same district and 11 other Italian provinces or European countries were instead purchased fromcommercial sources. Contents of 137 Cs, reported as Bq kg ‒1 dry weight (dw), were measured by γ-spectrometry. The radionuclide concentration varied depending on the gathering site in fresh samples, with 41.8 ± 5.2 Bq kg ‒1 dw at site 1 (Tosco-Emiliani Apennine) and four-fold less, 12.8 ± 1.3 Bq kg ‒1 dw, at site 2 (Apuan Alps). Moreover, fresh or dried carpophores from Lucca province displayed among the lowest 137 Cs contents in Europe. Average 137 Cs levels in all analysed samples were substantially below the legal threshold for edible mushrooms, 600 Bq kg ‒1 dw. Conclusively, we report that 137 Cs amounts in B. edulis depend on both the distance from the Chernobyl accident and multifactorial features of collection sites. We also show that the consumption of European B. edulis does not represent a major health risk with respect to 137 Cs radio contamination.

  20. Umbrella sampling of proton transfer in a creatine-water system

    Science.gov (United States)

    Ivchenko, Olga; Bachert, Peter; Imhof, Petra

    2014-04-01

    Proton transfer reactions are among the most common processes in chemistry and biology. Proton transfer between creatine and surrounding solvent water is underlying the chemical exchange saturation transfer used as a contrast in magnetic resonance imaging. The free energy barrier, determined by first-principles umbrella sampling simulations (EaDFT 3 kcal/mol) is in the same order of magnitude as the experimentally obtained activation energy. The underlying mechanism is a first proton transfer from the guanidinium group to the water pool, followed by a second transition where a proton is "transferred back" from the nearest water molecule to the deprotonated nitrogen atom of creatine.

  1. GROUND WATER SAMPLING OF VOCS IN THE WATER/CAPILLARY FRINGE AREA FOR VAPOR INTRUSION ASSESSMENT

    Science.gov (United States)

    Vapor intrusion has recently been considered a major pathway for increased indoor air contamination from certain volatile organic contaminants (VOCs). The recent Draft EPA Subsurface Vapor Intrusion Guidance Document states that ground water samples should be obtained from the u...

  2. Evaluation of the Purge Water Management System (PWMS) monitor well sampling technology at SRS

    International Nuclear Information System (INIS)

    Hiergesell, R.A.; Cardoso-Neto, J.E.; Williams, D.W.

    1997-01-01

    Due to the complex issues surrounding Investigation Derived Waste (IDW) at SRS, the Environmental Restoration Division has been exploring new technologies to deal with the purge water generated during monitoring well sampling. Standard procedures for sampling generates copious amounts of purge water that must be managed as hazardous waste, when containing hazardous and/or radiological contaminants exceeding certain threshold levels. SRS has obtained Regulator approval to field test an innovative surface release prevention mechanism to manage purge water. This mechanism is referred to as the Purge Water Management System (PWMS) and consists of a collapsible bladder situated within a rigid metal tank

  3. Polyhydroxyalkanoate Production on Waste Water Treatment Plants: Process Scheme, Operating Conditions and Potential Analysis for German and European Municipal Waste Water Treatment Plants

    Directory of Open Access Journals (Sweden)

    Timo Pittmann

    2017-06-01

    Full Text Available This work describes the production of polyhydroxyalkanoates (PHA as a side stream process on a municipal waste water treatment plant (WWTP and a subsequent analysis of the production potential in Germany and the European Union (EU. Therefore, tests with different types of sludge from a WWTP were investigated regarding their volatile fatty acids (VFA production-potential. Afterwards, primary sludge was used as substrate to test a series of operating conditions (temperature, pH, retention time (RT and withdrawal (WD in order to find suitable settings for a high and stable VFA production. In a second step, various tests regarding a high PHA production and stable PHA composition to determine the influence of substrate concentration, temperature, pH and cycle time of an installed feast/famine-regime were conducted. Experiments with a semi-continuous reactor operation showed that a short RT of 4 days and a small WD of 25% at pH = 6 and around 30 °C is preferable for a high VFA production rate (PR of 1913 mgVFA/(L×d and a stable VFA composition. A high PHA production up to 28.4% of cell dry weight (CDW was reached at lower substrate concentration, 20 °C, neutral pH-value and a 24 h cycle time. A final step a potential analysis, based on the results and detailed data from German waste water treatment plants, showed that the theoretically possible production of biopolymers in Germany amounts to more than 19% of the 2016 worldwide biopolymer production. In addition, a profound estimation regarding the EU showed that in theory about 120% of the worldwide biopolymer production (in 2016 could be produced on European waste water treatment plants.

  4. Monitoring of uranium concentrations in water samples collected near potentially hazardous objects in North-West Tajikistan.

    Science.gov (United States)

    Zoriy, P; Schläger, M; Murtazaev, K; Pillath, J; Zoriy, M; Heuel-Fabianek, B

    2018-01-01

    The water contamination near ecologically problematic objects was investigated between 2009 and 2014 in North-West Tajikistan as a part of a joint project between Forschungszentrum Jülich and Khujand State University. The main part of this work was the determination of uranium in water samples collected near the Degmay tailings dump, the Taboshar pit lake and the Syr Darya river. More than 130 water samples were collected and analyzed to monitor the uranium concentration near the investigated areas. Two different mass spectrometers and an ion chromatograph were used for element concentration measurements. Based on the results obtained, the uranium influence of the Degmay tailings on the rivers Khoja-Bakyrgan-Say and Syr Darya and surrounding water was not found. The uranium concentration in water samples was monitored for a lengthy period at seven locations Great differences in the uranium concentration in waters collected in 2010, 2011, 2012, 2013 for each location were not observed. Drinking water samples from the region of North-West Tajikistan were analyzed and compared with the World Health Organization's guidelines. Seven out of nine drinking water samples near Taboshar exceeded the WHO guideline value for uranium concentrations (30 μg/L). The average uranium concentration of water samples from Syr Darya for the period from 2009 to 2014 was determined to be 20.1 (±5.2) μg/L. The uranium contamination of the Syr Darya was determined from the western border to the eastern border and the results are shown in this paper. Copyright © 2017 Elsevier Ltd. All rights reserved.

  5. Genome-wide association study meta-analysis of European and Asian-ancestry samples identifies three novel loci associated with bipolar disorder.

    Science.gov (United States)

    Chen, D T; Jiang, X; Akula, N; Shugart, Y Y; Wendland, J R; Steele, C J M; Kassem, L; Park, J-H; Chatterjee, N; Jamain, S; Cheng, A; Leboyer, M; Muglia, P; Schulze, T G; Cichon, S; Nöthen, M M; Rietschel, M; McMahon, F J; Farmer, A; McGuffin, P; Craig, I; Lewis, C; Hosang, G; Cohen-Woods, S; Vincent, J B; Kennedy, J L; Strauss, J

    2013-02-01

    Meta-analyses of bipolar disorder (BD) genome-wide association studies (GWAS) have identified several genome-wide significant signals in European-ancestry samples, but so far account for little of the inherited risk. We performed a meta-analysis of ∼750,000 high-quality genetic markers on a combined sample of ∼14,000 subjects of European and Asian-ancestry (phase I). The most significant findings were further tested in an extended sample of ∼17,700 cases and controls (phase II). The results suggest novel association findings near the genes TRANK1 (LBA1), LMAN2L and PTGFR. In phase I, the most significant single nucleotide polymorphism (SNP), rs9834970 near TRANK1, was significant at the P=2.4 × 10(-11) level, with no heterogeneity. Supportive evidence for prior association findings near ANK3 and a locus on chromosome 3p21.1 was also observed. The phase II results were similar, although the heterogeneity test became significant for several SNPs. On the basis of these results and other established risk loci, we used the method developed by Park et al. to estimate the number, and the effect size distribution, of BD risk loci that could still be found by GWAS methods. We estimate that >63,000 case-control samples would be needed to identify the ∼105 BD risk loci discoverable by GWAS, and that these will together explain <6% of the inherited risk. These results support previous GWAS findings and identify three new candidate genes for BD. Further studies are needed to replicate these findings and may potentially lead to identification of functional variants. Sample size will remain a limiting factor in the discovery of common alleles associated with BD.

  6. {sup 222}Rn determination in water and brine samples using liquid scintillation spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira, Thiago C.; Oliveira, Arno H., E-mail: oliveiratco2010@gmail.com [Universidade Federal de Minas Gerais (DEN/UFMG), Belo Horizonte (Brazil). Departamento de Engenharia Nuclear; Monteiro, Roberto P.G.; Moreira, Rubens M., E-mail: rpgm@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN-CNEN-MG), Belo Horizonte, MG (Brazil)

    2017-07-01

    Liquid scintillation spectrometry (LSC) is the most common technique used for {sup 222}Rn determination in environmental aqueous sample. In this study, the performance of water-miscible (Ultima Gold AB) and immiscible (Optiscint) liquid scintillation cocktails has been compared for different matrices. {sup 241}Am, {sup 90}Sr and {sup 226}Ra standard solutions were used for LSC calibration. {sup 214}Po region was defined as better for both cocktails. Counting efficiency of 76 % and optimum PSA level of 95 for Ultima Gold AB cocktail, and counting efficiency of 82 % and optimum PSA level of 85 for Optiscint cocktail were obtained. Both cocktails showed similar results when applied for {sup 222}Rn activity determination in water and brine samples. However the Optiscint is recommended due to its quenching resistance. Limit of detection of 0.08 and 0.06 Bq l{sup -1} were obtained for water samples using a sample:cocktail ratio of 10:12 mL for Ultima Gold AB and Optiscint cocktails, respectively. Limit of detection of 0.08 and 0.04 Bq l{sup -1} were obtained for brine samples using a sample:cocktail ratio of 8:12 mL for Ultima Gold AB and Optiscint cocktails, respectively. (author)

  7. TRENDS IN AUTHORITARIANISM: EVIDENCE FROM 31 EUROPEAN COUNTRIES

    Directory of Open Access Journals (Sweden)

    Sabrina de Regt

    2011-01-01

    Full Text Available To date, few studies have been conducted on trendsin authoritarian attitudes,despite the importance of this research in our understanding of undemocraticmovements in society. Studies that have surveyed trends in authoritarianism arealready rather outdated, often based on student samples and conducted in only alimited number of countries. Furthermore, until now, no study had tested whetherthe meaning of authoritarianism is invariant acrosstime. Using theEuropeanValues Study,we examined trends in authoritarianism in 31 European countriesover the last decade (1999-2008, based on representative samples. It was foundthat in many Western European countries, with the exception of the Netherlands,authoritarianism declined significantly over the last decade. However, in some,mostly Eastern European countries, levels of authoritarianism actually increasedsignificantly during the last decade. Changing levels of authoritarianism werelinked to extreme-right and anti-democratic sentiment in European societies.

  8. Microbiology of the surface water samples in the high background radiation areas of Ramsar, Iran

    International Nuclear Information System (INIS)

    Motamedifar, Mohammad; Zamani, Khosrow; Sedigh, Hadi; Mortazavi, Seyed Mohammad Javad; Taeb, Shahram; Haghani, M.; Mortazavi, Seyed Ali Reza; Soofi, Amir

    2014-01-01

    Residents of high background radiation areas of Ramsar have lived in these areas for many generations and received radiation doses much higher than the dose limit recommended by ICRP for radiation workers. The radioactivity of the high background radiation areas of Ramsar is reported to be due to 226 Ra and its decay products, which have been brought to the surface by the waters of hot springs. Over the past years the department has focused on different aspects of the health effects of the elevated levels of natural radiation in Ramsar. This study was aimed to perform a preliminary investigation on the bioeffects of exposure to elevated levels of natural radiation on the microbiology of surface water samples. Water samples were collected from surface water streams in Talesh Mahalleh district, Ramsar as well as a nearby area with normal levels of background radiation. Only two strains of bacteria, that is, Providencia stuartii and Shimwellia blattae, could be isolated from the water samples collected from high background radiation areas, while seven strains (Escherichia coli, Enterobacter asburiae, Klebsiella pneumoniae, Shigella dysenteriae, Buttiauxella agerstis, Tatumella punctuata and Raoultella ornithinolytica) were isolated from the water samples collected from normal background radiation areas. All the bacteria isolated from water samples of high and normal background radiation areas were sensitive to ultraviolet radiation, heat, betadine, alcohol, and deconex. Although other investigators have reported that bacteria isolated from hot springs show radioresistance, the results reported here do not reveal any adaptive response. (author)

  9. Analysis of bromate in drinking water using liquid chromatography-tandem mass spectrometry without sample pretreatment.

    Science.gov (United States)

    Kosaka, Koji; Asami, Mari; Takei, Kanako; Akiba, Michihiro

    2011-01-01

    An analytical method for determining bromate in drinking water was developed using liquid chromatography-tandem mass spectrometry (LC-MS/MS). The (18)O-enriched bromate was used as an internal standard. The limit of quantification (LOQ) of bromate was 0.2 µg/L. The peak of bromate was separated from those of coexisting ions (i.e., chloride, nitrate and sulfate). The relative and absolute recoveries of bromate in two drinking water samples and in a synthesized ion solution (100 mg/L chloride, 10 mg N/L nitrate, and 100 mg/L sulfate) were 99-105 and 94-105%, respectively. Bromate concentrations in 11 drinking water samples determined by LC-MS/MS were water without sample pretreatment.

  10. Natural radioactivity in private water supplies in Devon

    International Nuclear Information System (INIS)

    Talbot, D.; Davis, J.; Rainey, M.

    2000-01-01

    This report details a study of the occurrence of natural radioactivity in private water Supplies in West Devon. Supplies sourced from wells, springs boreholes and a small number surface supplies were sampled. The findings of a laboratory simulation of the radon content in drinks such as tea, coffee and squash are also presented. Of supplies sampled in phase one of the work approximately 8% of tap water and 9% of samples directly from the supply contained radon at concentrations exceeding the draft European Union Commission Recommendation action level of 1000 Bq/I for individual and public water supplies. In a small number of supplies 238 U is present at levels exceeding 2 μg/I, the World Health Organisation (WHO) provisional guideline value for uranium in drinking water. The final aspect of the study looked at seasonal variation in the radon content of selected supplies. This showed considerable variability in radon concentration over the course of a week and between studies carried out several months apart. (author)

  11. Evaluation of methods to sample fecal indicator bacteria in foreshore sand and pore water at freshwater beaches.

    Science.gov (United States)

    Vogel, Laura J; Edge, Thomas A; O'Carroll, Denis M; Solo-Gabriele, Helena M; Kushnir, Caitlin S E; Robinson, Clare E

    2017-09-15

    Fecal indicator bacteria (FIB) are known to accumulate in foreshore beach sand and pore water (referred to as foreshore reservoir) where they act as a non-point source for contaminating adjacent surface waters. While guidelines exist for sampling surface waters at recreational beaches, there is no widely-accepted method to collect sand/sediment or pore water samples for FIB enumeration. The effect of different sampling strategies in quantifying the abundance of FIB in the foreshore reservoir is unclear. Sampling was conducted at six freshwater beaches with different sand types to evaluate sampling methods for characterizing the abundance of E. coli in the foreshore reservoir as well as the partitioning of E. coli between different components in the foreshore reservoir (pore water, saturated sand, unsaturated sand). Methods were evaluated for collection of pore water (drive point, shovel, and careful excavation), unsaturated sand (top 1 cm, top 5 cm), and saturated sand (sediment core, shovel, and careful excavation). Ankle-depth surface water samples were also collected for comparison. Pore water sampled with a shovel resulted in the highest observed E. coli concentrations (only statistically significant at fine sand beaches) and lowest variability compared to other sampling methods. Collection of the top 1 cm of unsaturated sand resulted in higher and more variable concentrations than the top 5 cm of sand. There were no statistical differences in E. coli concentrations when using different methods to sample the saturated sand. Overall, the unsaturated sand had the highest amount of E. coli when compared to saturated sand and pore water (considered on a bulk volumetric basis). The findings presented will help determine the appropriate sampling strategy for characterizing FIB abundance in the foreshore reservoir as a means of predicting its potential impact on nearshore surface water quality and public health risk. Copyright © 2017 Elsevier Ltd. All rights

  12. Screening and Quantification of Aliphatic Primary Alkyl Corrosion Inhibitor Amines in Water Samples by Paper Spray Mass Spectrometry.

    Science.gov (United States)

    Jjunju, Fred P M; Maher, Simon; Damon, Deidre E; Barrett, Richard M; Syed, S U; Heeren, Ron M A; Taylor, Stephen; Badu-Tawiah, Abraham K

    2016-01-19

    Direct analysis and identification of long chain aliphatic primary diamine Duomeen O (n-oleyl-1,3-diaminopropane), corrosion inhibitor in raw water samples taken from a large medium pressure water tube boiler plant water samples at low LODs (corrosion inhibitors in an industrial water boiler plant and other related samples in the water treatment industry. This approach was applied for the analysis of three complex water samples including feedwater, condensate water, and boiler water, all collected from large medium pressure (MP) water tube boiler plants, known to be dosed with varying amounts of polyamine and amine corrosion inhibitor components. Polyamine chemistry is widely used for example in large high pressure (HP) boilers operating in municipal waste and recycling facilities to prevent corrosion of metals. The samples used in this study are from such a facility in Coventry waste treatment facility, U.K., which has 3 × 40 tonne/hour boilers operating at 17.5 bar.

  13. Water pollution screening by large-volume injection of aqueous samples and application to GC/MS analysis of a river Elbe sample

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, S.; Efer, J.; Engewald, W. [Leipzig Univ. (Germany). Inst. fuer Analytische Chemie

    1997-03-01

    The large-volume sampling of aqueous samples in a programmed temperature vaporizer (PTV) injector was used successfully for the target and non-target analysis of real samples. In this still rarely applied method, e.g., 1 mL of the water sample to be analyzed is slowly injected direct into the PTV. The vaporized water is eliminated through the split vent. The analytes are concentrated onto an adsorbent inside the insert and subsequently thermally desorbed. The capability of the method is demonstrated using a sample from the river Elbe. By means of coupling this method with a mass selective detector in SIM mode (target analysis) the method allows the determination of pollutants in the concentration range up to 0.01 {mu}g/L. Furthermore, PTV enrichment is an effective and time-saving method for non-target analysis in SCAN mode. In a sample from the river Elbe over 20 compounds were identified. (orig.) With 3 figs., 2 tabs.

  14. Fipronil and two of its transformation products in water and European eel from the river Elbe.

    Science.gov (United States)

    Michel, N; Freese, M; Brinkmann, M; Pohlmann, J-D; Hollert, H; Kammann, U; Haarich, M; Theobald, N; Gerwinski, W; Rotard, W; Hanel, R

    2016-10-15

    Fipronil is an insecticide which, based on its mode of action, is intended to be predominantly toxic towards insects. Fipronil bioaccumulates and some of its transformation products were reported to be similar or even more stable in the environment and to show an enhanced toxicity against non-target organisms compared to the parent compound. The current study investigated the occurrence of Fipronil and two of its transformation products, Fipronil-desulfinyl and Fipronil-sulfone, in water as well as muscle and liver samples of eels from the river Elbe (Germany). In water samples total concentrations of FIP, FIP-d and FIP-s ranged between 0.5-1.6ngL(-1) with FIP being the main component in all water samples followed by FIP-s and FIP-d. In contrast, FIP-s was the main component in muscle and liver tissues of eels with concentrations of 4.05±3.73ngg(-1) ww and 19.91±9.96ngg(-1) ww, respectively. Using a physiologically based toxicokinetic (PBTK) model for moderately hydrophobic organic chemicals, the different distributions of FIP, FIP-d and FIP-s in water and related tissue samples could be attributed to metabolic processes of eels. The measured concentrations in water of all analytes and their fractional distribution did not reflect the assumed seasonal application of FIP and it seems that the water was constantly contaminated with FIP, FIP-d and FIP-s. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Sample collections from healthy volunteers for biological variation estimates' update: a new project undertaken by the Working Group on Biological Variation established by the European Federation of Clinical Chemistry and Laboratory Medicine.

    Science.gov (United States)

    Carobene, Anna; Strollo, Marta; Jonker, Niels; Barla, Gerhard; Bartlett, William A; Sandberg, Sverre; Sylte, Marit Sverresdotter; Røraas, Thomas; Sølvik, Una Ørvim; Fernandez-Calle, Pilar; Díaz-Garzón, Jorge; Tosato, Francesca; Plebani, Mario; Coşkun, Abdurrahman; Serteser, Mustafa; Unsal, Ibrahim; Ceriotti, Ferruccio

    2016-10-01

    Biological variation (BV) data have many fundamental applications in laboratory medicine. At the 1st Strategic Conference of the European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) the reliability and limitations of current BV data were discussed. The EFLM Working Group on Biological Variation is working to increase the quality of BV data by developing a European project to establish a biobank of samples from healthy subjects to be used to produce high quality BV data. The project involved six European laboratories (Milan, Italy; Bergen, Norway; Madrid, Spain; Padua, Italy; Istanbul, Turkey; Assen, The Netherlands). Blood samples were collected from 97 volunteers (44 men, aged 20-60 years; 43 women, aged 20-50 years; 10 women, aged 55-69 years). Initial subject inclusion required that participants completed an enrolment questionnaire to verify their health status. The volunteers provided blood specimens once per week for 10 weeks. A short questionnaire was completed and some laboratory tests were performed at each sampling consisting of blood collected under controlled conditions to provide serum, K2EDTA-plasma and citrated-plasma samples. Samples from six out of the 97 enroled subjects were discarded as a consequence of abnormal laboratory measurements. A biobank of 18,000 aliquots was established consisting of 120 aliquots of serum, 40 of EDTA-plasma, and 40 of citrated-plasma from each subject. The samples were stored at -80 °C. A biobank of well-characterised samples collected under controlled conditions has been established delivering a European resource to enable production of contemporary BV data.

  16. Parameters optimization using experimental design for headspace solid phase micro-extraction analysis of short-chain chlorinated paraffins in waters under the European water framework directive.

    Science.gov (United States)

    Gandolfi, F; Malleret, L; Sergent, M; Doumenq, P

    2015-08-07

    The water framework directives (WFD 2000/60/EC and 2013/39/EU) force European countries to monitor the quality of their aquatic environment. Among the priority hazardous substances targeted by the WFD, short chain chlorinated paraffins C10-C13 (SCCPs), still represent an analytical challenge, because few laboratories are nowadays able to analyze them. Moreover, an annual average quality standards as low as 0.4μgL(-1) was set for SCCPs in surface water. Therefore, to test for compliance, the implementation of sensitive and reliable analysis method of SCCPs in water are required. The aim of this work was to address this issue by evaluating automated solid phase micro-extraction (SPME) combined on line with gas chromatography-electron capture negative ionization mass spectrometry (GC/ECNI-MS). Fiber polymer, extraction mode, ionic strength, extraction temperature and time were the most significant thermodynamic and kinetic parameters studied. To determine the suitable factors working ranges, the study of the extraction conditions was first carried out by using a classical one factor-at-a-time approach. Then a mixed level factorial 3×2(3) design was performed, in order to give rise to the most influent parameters and to estimate potential interactions effects between them. The most influent factors, i.e. extraction temperature and duration, were optimized by using a second experimental design, in order to maximize the chromatographic response. At the close of the study, a method involving headspace SPME (HS-SPME) coupled to GC/ECNI-MS is proposed. The optimum extraction conditions were sample temperature 90°C, extraction time 80min, with the PDMS 100μm fiber and desorption at 250°C during 2min. Linear response from 0.2ngmL(-1) to 10ngmL(-1) with r(2)=0.99 and limits of detection and quantification, respectively of 4pgmL(-1) and 120pgmL(-1) in MilliQ water, were achieved. The method proved to be applicable in different types of waters and show key advantages, such

  17. A rapid and simple separation method of Tc-99 in water samples

    International Nuclear Information System (INIS)

    Uchida, Shigeo; Tagami, Keiko

    1999-01-01

    Technetium-99 ( 99 Tc) is one of the important elements on safety evaluation of reprocessing plant and waste disposal plant, because it is a long half-life nuclide and large fission yield (about 6%) from 235 U and 239 Pu. We studied in this work a rapid and simple separation method of 99 Tc in water samples by ICP-MS. Tc in 2 litre of inland water or 1.5 litre of sea water sample solutions was condensed and separated by mini-column resin (TEVA·Spec resin) (Eichrom Co., Ltd.). The experimental results showed the best conditions as followed that 1) after controlling 0.1M nitric acid sample solution, passed it through the column, 2) then the inhibitory elements such as Ru are removed by 40 ml of 2M nitric acid solution, and 3) Tc was recovered by 4 ml of 8M nitric acid solution. 95% or more recovery of Tc was obtained. 100% Ru, an inhibited element of ICP-MS, was removed. The elute obtained from 4 ml of 8M nitric acid solution was diluted ten times with pure water and 99 Tc was measured by ICP-MS. The limit of detection of 2 litre inland water and 1.5 litre sea water were 3 mBql -1 and 4 mBql -1 , respectively. The organic compounds were not removed before running to column, because the concentration of organic compounds was not so large. When large amounts of them are contained, they should be removed. If suspended materials absorb Tc, Tc should be changed to TcO 4 - . (S.Y.)

  18. Study of the concentration of 7 Be in samples of rain water

    International Nuclear Information System (INIS)

    Quintero P, E.; Rojas M, V.P.

    2004-01-01

    This work shows the methodology carried out for the determination of 7 Be in samples of rain water and the obtained results of the concentration of having said radionuclide in this sampled matrix during the last five years in the Nuclear Center of Mexico. (Author)

  19. Microbial diversity in firework chemical exposed soil and water samples collected in Virudhunagar district, Tamil Nadu, India.

    Science.gov (United States)

    Dhasarathan, P; Theriappan, P; Ashokraja, C

    2010-03-01

    Microbial diversity of soil and water samples collected from pyrochemicals exposed areas of Virdhunagar district (Tamil Nadu, India) was studied. Soil and water samples from cultivable area, waste land and city area of the same region were also studied for a comparative acount. There is a remarkable reduction in total heterotrophic bacterial population (THB) in pyrochemicals exposed soil and water samples (42 × 10(4) CFU/g and 5.6 × 10(4) CFU/ml respectively), compared to the THB of cultivable area soil and water samples (98 × 10(7) CFU/g and 38.6 × 10(7) CFU/ml). The generic composition the THB of the pyrochemicals exposed samples too exhibited considerable change compared to other samples. Pseudomonas sp. was the predominant one (41.6%) followed by Achromobacter sp. (25%) in pyrochemical exposed soil and Pseudomonas sp. was the predominant one (25%) in pyrochemical exposed water samples followed by Bacillus sp. (25%) and Micrococcus sp. (16.6%). It was observed that Cornybacterium sp. and Micrococcus sp. were absent completely in pyrochemical exposed soil and Achromobacter sp. was missing in the pyrochemical exposed water samples, which were present in the other samples. The outcome of this study clearly demonstrates that pollutants such as chemicals used in pyrotechniques affect the microbial biodiversity and suitable measures have to be taken to control the pollution level and to save biodiversity.

  20. Effects of water treatment and sample granularity on radiation sensitivity and stability of EPR signals in X-ray irradiated bone samples

    International Nuclear Information System (INIS)

    Ciesielski, Bartlomiej; Krefft, Karolina; Penkowski, Michal; Kaminska, Joanna; Drogoszewska, Barbara

    2014-01-01

    The article describes effects of sample conditions during its irradiation and electron paramagnetic resonance (EPR) measurements on the background (BG) and dosimetric EPR signals in bone. Intensity of the BG signal increased up to two to three times after crushing of bone to sub-millimetre grains. Immersion of samples in water caused about 50 % drop in intensity of the BG component followed by its regrowth in 1-2 months. Irradiation of bone samples produced an axial dosimetric EPR signal (radiation-induced signal) attributed to hydroxyapatite component of bone. This signal was stable and was not affected by water. In samples irradiated in dry conditions, EPR signal similar to the native BG was also generated by radiation. In samples irradiated in wet conditions, this BG-like component was initially much smaller than in bone irradiated as dry, but increased in time, reaching similar levels as in dry-irradiated samples. It is concluded that accuracy of EPR dosimetry in bones can be improved, if calibration of the samples is done by their irradiations in wet conditions. (authors)

  1. Micellar electrokinetic chromatographic determination of triazine herbicides in water samples.

    Science.gov (United States)

    Li, Zhi; Zhang, Shuaihua; Yin, Xiaofang; Wang, Chun; Wang, Zhi

    2014-09-01

    Dispersive liquid-liquid microextraction combined with online sweeping preconcentration in micellar electrokinetic chromatography was developed for the simultaneous determination of five triazine herbicides (atrazine, simazine, propazine, prometon and simetryn) in water samples. Several experimental parameters affecting the extraction efficiencies such as the type and volume of both the extraction and dispersive solvents, the addition of salt to sample solution, the extraction time and the pH of the sample solution were investigated. Under optimum conditions, the linearity of the method was good in the range from 0.33 to 20 ng mL(-1) for simazine, propazine, atrazine and simetryn, and from 0.17 to 20 ng mL(-1) for prometon, respectively. The sensitivity enrichment factors were in the range from 1750 to 2100, depending on the compound. The limit of detection (S/N = 3) ranged from 0.05 to 0.10 ng mL(-1). The developed method was successfully applied to the analysis of the five triazines in river, ground and well waters. © The Author [2013]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Daily variations of delta 18O and delta D in daily samplings of air water vapour and rain water in the Amazon Basin

    International Nuclear Information System (INIS)

    Matsui, E.; Salati, E.; Ribeiro, M.N.G.; Tancredi, A.C.F.N.S.; Reis, C.M. dos

    1984-01-01

    The movement of rain water in the soil from 0 to 120 cm depth using delta 18 O weekly variations is studied. A study of the delta D variability in water vapour and rain water samples during precipitation was also done, the samples being collected a 3 minute intervals from the beginning to the end of precipitation. (M.A.C.) [pt

  3. Water Quality Sampling Locations Along the Shoreline of the Columbia River, Hanford Site, Washington

    Energy Technology Data Exchange (ETDEWEB)

    Peterson, Robert E.; Patton, Gregory W.

    2009-12-14

    As environmental monitoring evolved on the Hanford Site, several different conventions were used to name or describe location information for various sampling sites along the Hanford Reach of the Columbia River. These methods range from handwritten descriptions in field notebooks to the use of modern electronic surveying equipment, such as Global Positioning System receivers. These diverse methods resulted in inconsistent archiving of analytical results in various electronic databases and published reports because of multiple names being used for the same site and inaccurate position data. This document provides listings of sampling sites that are associated with groundwater and river water sampling. The report identifies names and locations for sites associated with sampling: (a) near-river groundwater using aquifer sampling tubes; (b) riverbank springs and springs areas; (c) pore water collected from riverbed sediment; and (d) Columbia River water. Included in the listings are historical names used for a particular site and the best available geographic coordinates for the site, as of 2009. In an effort to create more consistency in the descriptive names used for water quality sampling sites, a naming convention is proposed in this document. The convention assumes that a unique identifier is assigned to each site that is monitored and that this identifier serves electronic database management requirements. The descriptive name is assigned for the convenience of the subsequent data user. As the historical database is used more intensively, this document may be revised as a consequence of discovering potential errors and also because of a need to gain consensus on the proposed naming convention for some water quality monitoring sites.

  4. The footprint of bottom trawling in European waters

    NARCIS (Netherlands)

    Eigaard, Ole R.; Bastardie, Francois; Hintzen, Niels T.; Buhl-Mortensen, Lene; Buhl-Mortensen, Pål; Catarino, Rui; Dinesen, Grete E.; Egekvist, Josefine; Fock, Heino O.; Geitner, Kerstin; Gerritsen, Hans D.; González, Manuel Marín; Jonsson, Patrik; Kavadas, Stefanos; Laffargue, Pascal; Lundy, Mathieu; Gonzalez-Mirelis, Genoveva; Nielsen, J.R.; Papadopoulou, Nadia; Posen, Paulette E.; Pulcinella, Jacopo; Russo, Tommaso; Sala, Antonello; Silva, Cristina; Smith, Christopher J.; Vanelslander, Bart; Rijnsdorp, Adriaan D.

    2017-01-01

    Mapping trawling pressure on the benthic habitats is needed as background to support an ecosystem approach to fisheries management. The extent and intensity of bottom trawling on the European continental shelf (0-1000 m) was analysed from logbook statistics and vessel monitoring system data for

  5. The installation of a multiport ground-water sampling system in the 300 Area

    International Nuclear Information System (INIS)

    Gilmore, T.J.

    1989-06-01

    In 1988, the Pacific Northwest Laboratory installed a multiport groundwater sampling system in well 399-1-20, drilled north of the 300 Area on the Hanford Site in southwestern Washington State. The purpose of installing the multiport system is to evaluate methods of determining the vertical distribution of contaminants and hydraulic heads in ground water. Well 399-1-20 is adjacent to a cluster of four Resource Conservation and Recovery Act (RCRA) ground-water monitoring wells. This proximity makes it possible to compare sampling intervals and head measurements between the multiport system and the RCRA monitoring wells. Drilling and installation of the multiport system took 42 working days. Six sampling ports were installed in the upper unconfined aquifer at depths of approximately 120, 103, 86, 74, 56, and 44 feet. The locations of the sampling ports were determined by the hydrogeology of the area and the screened intervals of adjacent ground-water monitoring wells. The system was installed by backfilling sand around the sampling ports and isolating the ports with bentonite seals. The method proved adequate. For future installation, however, development and evaluation of an alternative method is recommended. In the alternative method suggested, the multiport system would be placed inside a cased and screened well, using packers to isolate the sampling zones. 4 refs., 8 figs., 1 tab

  6. Guidance document for preparing water sampling and analysis plans for UMTRA Project sites. Revision 1

    International Nuclear Information System (INIS)

    1995-09-01

    A water sampling and analysis plan (WSAP) is prepared for each Uranium Mill Tailings Remedial Action (UMTRA) Project site to provide the rationale for routine ground water sampling at disposal sites and former processing sites. The WSAP identifies and justifies the sampling locations, analytical parameters, detection limits, and sampling frequency for the routine ground water monitoring stations at each site. This guidance document has been prepared by the Technical Assistance Contractor (TAC) for the US Department of Energy (DOE). Its purpose is to provide a consistent technical approach for sampling and monitoring activities performed under the WSAP and to provide a consistent format for the WSAP documents. It is designed for use by the TAC in preparing WSAPs and by the DOE, US Nuclear Regulatory Commission, state and tribal agencies, other regulatory agencies, and the public in evaluating the content of WSAPS

  7. Drinking Water Quality Forecast of Peshawar Valley on the Basis of Sample Data

    International Nuclear Information System (INIS)

    Khan, S.U.; Bangash, F.K.

    2001-01-01

    Microbiological and related parameters of 75 portable water samples collected from source, distribution line and consumer tap in 25 different locations were investigated. The findings were used to forecast statistically the quality of drinking water of hole valley at all three sites and compared with WHO's standards. The study shows that the valley has good water deposits and suitable for drinking purposes however the same quality is not maintained throughout the distribution systems. The presence of total and fecal coliform in the samples collected from distribution line and consumer tap shows the mixing of wastewater through leaky joints and corroded underground supply system. The study also shows poor disinfecting practices in the study area. On the basis of this study we can say that the area got excellent subsoil water deposits but most of the consumers are supplied with water not fit for drinking purposes which is the main cause of Heath problems in the area. (author)

  8. Sampling design and procedures for fixed surface-water sites in the Georgia-Florida coastal plain study unit, 1993

    Science.gov (United States)

    Hatzell, H.H.; Oaksford, E.T.; Asbury, C.E.

    1995-01-01

    The implementation of design guidelines for the National Water-Quality Assessment (NAWQA) Program has resulted in the development of new sampling procedures and the modification of existing procedures commonly used in the Water Resources Division of the U.S. Geological Survey. The Georgia-Florida Coastal Plain (GAFL) study unit began the intensive data collection phase of the program in October 1992. This report documents the implementation of the NAWQA guidelines by describing the sampling design and procedures for collecting surface-water samples in the GAFL study unit in 1993. This documentation is provided for agencies that use water-quality data and for future study units that will be entering the intensive phase of data collection. The sampling design is intended to account for large- and small-scale spatial variations, and temporal variations in water quality for the study area. Nine fixed sites were selected in drainage basins of different sizes and different land-use characteristics located in different land-resource provinces. Each of the nine fixed sites was sampled regularly for a combination of six constituent groups composed of physical and chemical constituents: field measurements, major ions and metals, nutrients, organic carbon, pesticides, and suspended sediments. Some sites were also sampled during high-flow conditions and storm events. Discussion of the sampling procedure is divided into three phases: sample collection, sample splitting, and sample processing. A cone splitter was used to split water samples for the analysis of the sampling constituent groups except organic carbon from approximately nine liters of stream water collected at four fixed sites that were sampled intensively. An example of the sample splitting schemes designed to provide the sample volumes required for each sample constituent group is described in detail. Information about onsite sample processing has been organized into a flowchart that describes a pathway for each of

  9. Metal-organic framework based in-syringe solid-phase extraction for the on-site sampling of polycyclic aromatic hydrocarbons from environmental water samples.

    Science.gov (United States)

    Zhang, Xiaoqiong; Wang, Peiyi; Han, Qiang; Li, Hengzhen; Wang, Tong; Ding, Mingyu

    2018-04-01

    In-syringe solid-phase extraction is a promising sample pretreatment method for the on-site sampling of water samples because of its outstanding advantages of portability, simple operation, short extraction time, and low cost. In this work, a novel in-syringe solid-phase extraction device using metal-organic frameworks as the adsorbent was fabricated for the on-site sampling of polycyclic aromatic hydrocarbons from environmental waters. Trace polycyclic aromatic hydrocarbons were effectively extracted through the self-made device followed by gas chromatography with mass spectrometry analysis. Owing to the excellent adsorption performance of metal-organic frameworks, the analytes could be completely adsorbed during one adsorption cycle, thus effectively shortening the extraction time. Moreover, the adsorbed analytes could remain stable on the device for at least 7 days, revealing the potential of the self-made device for on-site sampling of degradable compounds in remote regions. The limit of detection ranged from 0.20 to 1.9 ng/L under the optimum conditions. Satisfactory recoveries varying from 84.4 to 104.5% and relative standard deviations below 9.7% were obtained in real samples analysis. The results of this study promote the application of metal-organic frameworks in sample preparation and demonstrate the great potential of in-syringe solid-phase extraction for the on-site sampling of trace contaminants in environmental waters. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  10. Infrared thermometry and the crop water stress index. II. Sampling procedures and interpretation

    International Nuclear Information System (INIS)

    Gardner, B.R.; Nielsen, D.C.; Shock, C.C.

    1992-01-01

    Infrared thermometry can be a valuable research and production tool for detecting and quantifying water stress in plants, as shown by a large volume of published research. Users of infrared thermometers (IRT) should be aware of the many equipment, environmental, and plant factors influencing canopy temperature measured by an IRT. The purpose of this paper is to describe factors influencing measured plant temperature, outline sampling procedures that will produce reliable Crop Water Stress Index (CWSI) values, and offer interpretations of CWSI and plant temperatures relative to crop production and other water stress parameters by reviewing previously conducted research. Factors that are considered are IRT condition, configuration, and position; psychrometer location; wind speed; solar radiation; time of day; leaf area and orientation; and appropriate non-water-stressed baseline equation. Standard sampling and CWSI calculation procedures are proposed. Use of CWSI with crops varying in type of response to water stress is described. Previously conducted research on plant temperatures or CWSI is tabulated by crop and water stress parameters measured. The paper provides valuable information to assist interested users of IRTs in making reliable water stress measurements. (author)

  11. Infrared thermometry and the crop water stress index. II. Sampling procedures and interpretation

    Energy Technology Data Exchange (ETDEWEB)

    Gardner, B. R. [BP Research, Cleveland, OH (United States); Nielsen, D. C.; Shock, C. C.

    1992-10-15

    Infrared thermometry can be a valuable research and production tool for detecting and quantifying water stress in plants, as shown by a large volume of published research. Users of infrared thermometers (IRT) should be aware of the many equipment, environmental, and plant factors influencing canopy temperature measured by an IRT. The purpose of this paper is to describe factors influencing measured plant temperature, outline sampling procedures that will produce reliable Crop Water Stress Index (CWSI) values, and offer interpretations of CWSI and plant temperatures relative to crop production and other water stress parameters by reviewing previously conducted research. Factors that are considered are IRT condition, configuration, and position; psychrometer location; wind speed; solar radiation; time of day; leaf area and orientation; and appropriate non-water-stressed baseline equation. Standard sampling and CWSI calculation procedures are proposed. Use of CWSI with crops varying in type of response to water stress is described. Previously conducted research on plant temperatures or CWSI is tabulated by crop and water stress parameters measured. The paper provides valuable information to assist interested users of IRTs in making reliable water stress measurements. (author)

  12. Halogenated methanesulfonic acids: A new class of organic micropollutants in the water cycle.

    Science.gov (United States)

    Zahn, Daniel; Frömel, Tobias; Knepper, Thomas P

    2016-09-15

    Mobile and persistent organic micropollutants may impact raw and drinking waters and are thus of concern for human health. To identify such possible substances of concern nineteen water samples from five European countries (France, Switzerland, The Netherlands, Spain and Germany) and different compartments of the water cycle (urban effluent, surface water, ground water and drinking water) were enriched with mixed-mode solid phase extraction. Hydrophilic interaction liquid chromatography - high resolution mass spectrometry non-target screening of these samples led to the detection and structural elucidation of seven novel organic micropollutants. One structure could already be confirmed by a reference standard (trifluoromethanesulfonic acid) and six were tentatively identified based on experimental evidence (chloromethanesulfonic acid, dichloromethanesulfonic acid, trichloromethanesulfonic acid, bromomethanesulfonic acid, dibromomethanesulfonic acid and bromochloromethanesulfonic acid). Approximated concentrations for these substances show that trifluoromethanesulfonic acid, a chemical registered under the European Union regulation REACH with a production volume of more than 100 t/a, is able to spread along the water cycle and may be present in concentrations up to the μg/L range. Chlorinated and brominated methanesulfonic acids were predominantly detected together which indicates a common source and first experimental evidence points towards water disinfection as a potential origin. Halogenated methanesulfonic acids were detected in drinking waters and thus may be new substances of concern. Copyright © 2016 Elsevier Ltd. All rights reserved.

  13. Evaluation of the Validity of Groundwater Samples Obtained Using the Purge Water Management System at SRS

    International Nuclear Information System (INIS)

    Beardsley, C.C.

    1999-01-01

    As part of the demonstration testing of the Purge Water Management System (PWMS) technology at the Savannah River Site (SRS), four wells were equipped with PWMS units in 1997 and a series of sampling events were conducted at each during 1997-1998. Three of the wells were located in A/M Area while the fourth was located at the Old Radioactive Waste Burial Ground in the General Separations Area.The PWMS is a ''closed-loop'', non-contact, system used to collect and return purge water to the originating aquifer after a sampling event without having significantly altered the water quality. One of the primary concerns as to its applicability at SRS, and elsewhere, is whether the PWMS might resample groundwater that is returned to the aquifer during the previous sampling event. The purpose of the present investigation was to compare groundwater chemical analysis data collected at the four test wells using the PWMS vs. historical data collected using the standard monitoring program methodology to determine if the PWMS provides representative monitoring samples.The analysis of the groundwater chemical concentrations indicates that the PWMS sampling methodology acquired representative groundwater samples at monitoring wells ABP-1A, ABP-4, ARP-3 and BGO-33C. Representative groundwater samples are achieved if the PWMS does not resample groundwater that has been purged and returned during a previous sampling event. Initial screening calculations, conducted prior to the selection of these four wells, indicated that groundwater velocities were high enough under the ambient hydraulic gradients to preclude resampling from occurring at the time intervals that were used at each well. Corroborating evidence included a tracer test that was conducted at BGO-33C, the high degree of similarity between analyte concentrations derived from the PWMS samples and those obtained from historical protocol sampling, as well as the fact that PWMS data extend all previously existing concentration

  14. Pore water sampling in acid sulfate soils: a new peeper method.

    Science.gov (United States)

    Johnston, Scott G; Burton, Edward D; Keene, Annabelle F; Bush, Richard T; Sullivan, Leigh A; Isaacson, Lloyd

    2009-01-01

    This study describes the design, deployment, and application of a modified equilibration dialysis device (peeper) optimized for sampling pore waters in acid sulfate soils (ASS). The modified design overcomes the limitations of traditional-style peepers, when sampling firm ASS materials over relatively large depth intervals. The new peeper device uses removable, individual cells of 25 mL volume housed in a 1.5 m long rigid, high-density polyethylene rod. The rigid housing structure allows the device to be inserted directly into relatively firm soils without requiring a supporting frame. The use of removable cells eliminates the need for a large glove-box after peeper retrieval, thus simplifying physical handling. Removable cells are easily maintained in an inert atmosphere during sample processing and the 25-mL sample volume is sufficient for undertaking multiple analyses. A field evaluation of equilibration times indicates that 32 to 38 d of deployment was necessary. Overall, the modified method is simple and effective and well suited to acquisition and processing of redox-sensitive pore water profiles>1 m deep in acid sulfate soil or any other firm wetland soils.

  15. Evaluation of wastewater contaminant transport in surface waters using verified Lagrangian sampling

    Science.gov (United States)

    Antweiler, Ronald C.; Writer, Jeffrey H.; Murphy, Sheila F.

    2014-01-01

    Contaminants released from wastewater treatment plants can persist in surface waters for substantial distances. Much research has gone into evaluating the fate and transport of these contaminants, but this work has often assumed constant flow from wastewater treatment plants. However, effluent discharge commonly varies widely over a 24-hour period, and this variation controls contaminant loading and can profoundly influence interpretations of environmental data. We show that methodologies relying on the normalization of downstream data to conservative elements can give spurious results, and should not be used unless it can be verified that the same parcel of water was sampled. Lagrangian sampling, which in theory samples the same water parcel as it moves downstream (the Lagrangian parcel), links hydrologic and chemical transformation processes so that the in-stream fate of wastewater contaminants can be quantitatively evaluated. However, precise Lagrangian sampling is difficult, and small deviations – such as missing the Lagrangian parcel by less than 1 h – can cause large differences in measured concentrations of all dissolved compounds at downstream sites, leading to erroneous conclusions regarding in-stream processes controlling the fate and transport of wastewater contaminants. Therefore, we have developed a method termed “verified Lagrangian” sampling, which can be used to determine if the Lagrangian parcel was actually sampled, and if it was not, a means for correcting the data to reflect the concentrations which would have been obtained had the Lagrangian parcel been sampled. To apply the method, it is necessary to have concentration data for a number of conservative constituents from the upstream, effluent, and downstream sites, along with upstream and effluent concentrations that are constant over the short-term (typically 2–4 h). These corrections can subsequently be applied to all data, including non-conservative constituents. Finally, we

  16. Evaluation of wastewater contaminant transport in surface waters using verified Lagrangian sampling.

    Science.gov (United States)

    Antweiler, Ronald C; Writer, Jeffrey H; Murphy, Sheila F

    2014-02-01

    Contaminants released from wastewater treatment plants can persist in surface waters for substantial distances. Much research has gone into evaluating the fate and transport of these contaminants, but this work has often assumed constant flow from wastewater treatment plants. However, effluent discharge commonly varies widely over a 24-hour period, and this variation controls contaminant loading and can profoundly influence interpretations of environmental data. We show that methodologies relying on the normalization of downstream data to conservative elements can give spurious results, and should not be used unless it can be verified that the same parcel of water was sampled. Lagrangian sampling, which in theory samples the same water parcel as it moves downstream (the Lagrangian parcel), links hydrologic and chemical transformation processes so that the in-stream fate of wastewater contaminants can be quantitatively evaluated. However, precise Lagrangian sampling is difficult, and small deviations - such as missing the Lagrangian parcel by less than 1h - can cause large differences in measured concentrations of all dissolved compounds at downstream sites, leading to erroneous conclusions regarding in-stream processes controlling the fate and transport of wastewater contaminants. Therefore, we have developed a method termed "verified Lagrangian" sampling, which can be used to determine if the Lagrangian parcel was actually sampled, and if it was not, a means for correcting the data to reflect the concentrations which would have been obtained had the Lagrangian parcel been sampled. To apply the method, it is necessary to have concentration data for a number of conservative constituents from the upstream, effluent, and downstream sites, along with upstream and effluent concentrations that are constant over the short-term (typically 2-4h). These corrections can subsequently be applied to all data, including non-conservative constituents. Finally, we show how data

  17. Difficulties in obtaining representative samples for compliance with the Ballast Water Management Convention

    Digital Repository Service at National Institute of Oceanography (India)

    Carney, K.J; Basurko, O.C; Pazouki, K.; Marsham, S.; Delany, J; Desai, D.V.; Anil, A.C; Mesbahi, E.

    water, the shape, size and number of ballast tanks and the heterogeneous distribution of organisms within tanks. These factors hinder efforts to obtain samples that truly represent the total ballast water onboard a vessel. A known cell density...

  18. Determination of radiocaesium in agriculture-related water samples containing suspended solids using gelling method

    International Nuclear Information System (INIS)

    Matsunami, Hisaya; Shin, Moono; Takahashi, Yoshihiko; Shinano, Takuro; Kitajima, Shiori; Tsuchiya, Takashi

    2015-01-01

    After the TEPCO Fukushima Dai-ichi Nuclear Power Plant accident in 2011, the radiocaesium, which flowed into the paddy fields via irrigation water, have been widely investigated. When the concentration of radiocaesium in the water samples containing suspended solids were directly measured using a high purity germanium detector with a 2 L marinelli beaker, the radiocaesium concentration might be overestimated due to the sedimentation of the suspended solids during the measurement time. In fact, the values obtained by the direct method were higher than those obtained by the filtering method and/or the gelling method in most of the agriculture-related water samples. We concluded that the gelling method using sodium polyacrylate can be widely adapted for the analysis of the total radiocaesium in the agriculture-related water samples because of its many advantage such as simple preparation procedure, accurate analysis values, excellent long-term stability of geometry and low operating cost. (author)

  19. Determination of Cs-134 and Cs-137 rain water samples

    International Nuclear Information System (INIS)

    Lima, M.F.; Mazzilli, B.

    1988-01-01

    In order to setting an environmental monitoring program at IPEN, was developed a fast and simple methodology for concentration of Cs-134 and Cs-137 in rain water. This procedure consists in the precipitation of cesium and others cathions of its family (NH 4 + , K + and Rb + ) by ammonium molybdophosphate. The measures of the desintegration rates of Cs-134 and Cs-137 was done by gamma spectrometry in a Ge(Li) detector. After setting up the ideal experimental conditions, the procedure was used to analyze four samples of rain water. (author) [pt

  20. Source Classification Framework for an optimized European wide Emission Control Strategy

    DEFF Research Database (Denmark)

    Lützhøft, Hans-Christian Holten; Donner, Erica; Ledin, Anna

    2011-01-01

    of the PS environmental emission. The SCF also provides a well structured approach for European pollutant source and release classification and management. With further European wide implementation, the SCF has the potential or an optimized ECS in order to obtain good chemical status of European water...

  1. Demonstration/Validation of the Snap Sampler Passive Ground Water Sampling Device

    Science.gov (United States)

    2011-06-01

    purging and sampling protocol. Analytes that were measured at the Pease site included total and dissolved concentrations of arsenic (As), calcium ...samples remain in the original bottle in which they were collected, presumably losses of volatiles and changes in concentrations of dissolved gases or...because of excavation and removal. This has resulted in hydraulically interconnected bedrock and overburden water- bearing zones in much of this area

  2. Assessment of Heavy Metals in Water Samples of Certain Locations Situated Around Tumkur, Karnataka, India

    Directory of Open Access Journals (Sweden)

    C. Vijaya Bhaskar

    2010-01-01

    Full Text Available Surface water and groundwater samples of certain locations namely Kallambella, Bugudanahalli, Maidala, Honnudike, Kunigal, Kadaba and Hebbur, situated around Tumkur were assessed in the month of September 2008 for pH, EC and heavy metals Cd, Cu, Fe, Hg, Mn, Zn and Ni. The pH vales of surface waters were in alkaline range of 7.8-8.2 and are well within safe limits for crop production. The pH of ground- water was in the range of 7.6-8.4. The conductivity was in the range of 0.20-0.68 mS/cm and 0.34-2.44 mS/cm for surface and groundwaters respectively. High EC value of Kallambella groundwater accounts for its salinity. All surface waters except Honnudike and Hebbur samples contain low concentrations of these metals and are ideal for irrigation. Though the samples from Honnudike, Kadaba and Hebbur have high iron concentration, only Honnudike and Hebbur samples have exceeded the limit of 5 mg/L required for irrigation. In groundwaters the concentrations of all these heavy metals except copper are also well in permissible limits and suitable for drinking. Cu, Fe, Ni and Zn were detected in all the samples and found in the range of 0.094-0.131, 0.958-12.537, 0.020-0.036 and 0.082-1.139 mg/L respectively in surface waters and these are in the range of 0.132-0.142, 0.125-1.014, 0.028-0.036 and 0.003-0.037 mg/L in ground- waters. The elements cadmium, mercury and manganese are absent in all the samples.

  3. [Microbiological public health aspects in the use of rain water as water reservoirs for toilet flushing, garden irrigation and laundry].

    Science.gov (United States)

    Holländer, R; Bullermann, M; Gross, C; Hartung, H; König, K; Lücke, F K; Nolde, E

    1996-05-01

    From a total of 102 rain water cisterns in use for toilet flushing, garden irrigation and laundering washing about 1,600 water samples were collected and subjected to microbiological analysis. The assays included aerobic heterotrophic microorganisms growing at 20 and 37 degrees C, respectively, as well as the identification of Escherichia coli, coliform organisms, faecal streptococci, Pseudomonas aeruginosa, staphylococci, yersiniae, salmonellae, shigellae, legionellae and yeasts. The median of the total number of cells per ml was 1,200 at 20 degrees C and 230 at 37 degrees C, respectively. Approximately 26 E. coli cells and 198 coliform organisms (median values) were found per 100 ml. In the case of cisterns manufactured of plastic the total number of cells was generally found to be lower than in samples collected from concrete or brick-made storage tanks. With the exception of the ubiquitously distributed organism Pseudomonas aeruginosa (found in 11.8% of the samples) and salmonella in only one sample, no other pathogens were detected. More than 95% of all analysed samples met the quality standards for bathing waters as set by the European Community. Provided certain precautions are taken, such as strict separation of mains for drinking water and rain water, as well as correct labelling of pipelines and collection sites, the use of rain water for toilet flushing, garden irrigation and laundry washing presents no unacceptable risk to public health.

  4. Procedures for the collection and preservation of groundwater and surface water samples and for the installation of monitoring wells

    International Nuclear Information System (INIS)

    Korte, N.; Kearl, P.

    1984-01-01

    Proper sampling procedures are essential for a successful water-quality monitoring program. It must be emphasized, however, that it is impossible to maintain absolutely in-situ conditions when collecting and preserving a water sample, whether from a flowing stream or an aquifer. Consequently, the most that can reasonably be expected is to collect a best possible sample with minimal disturbance. This document describes procedures for installing monitoring wells and for collecting samples of surface water and groundwater. The discussion of monitoring wells includes mention of multilevel sampling and a general overview of vadose-zone monitoring. Guidelines for well installation are presented in detail. The discussion of water-sample collection contains evaluations of sampling pumps, filtration equipment, and sample containers. Sample-preservation techniques, as published by several government and private sources, are reviewed. Finally, step-by-step procedures for collection of water samples are provided; these procedures address such considerations as necessary equipment, field operations, and written documentation. Separate procedures are also included for the collection of samples for determination of sulfide and for reactive aluminum. The report concludes with a brief discussion of adverse sampling, conditions that may significantly affect the quality of the data. Appendix A presents a rationale for the development and use of statistical considerations in water sampling to ensure a more complete water quality monitoring program. 51 references, 9 figures, 4 tables

  5. Results of environmental radioactivity measurements in the Member States of European Community for air-deposition-water 1973-1974, milk 1972-1973-1974

    International Nuclear Information System (INIS)

    1977-01-01

    The present document is the fifteenth report published by the Health and Safety Directorate of the Commission of the European Communities concerning ambient radioactivity and using the data collected by the stations in charge of the surveillance of the environmental radioactivity in Member States. The results are compiled and extracted from the data sent to the Commission in application of Article 36 of the Treaty of Rome instituting the European Atomic Energy Community. It is the first document in which data from Denmark, Ireland and the United Kingdom which joined the European Community on 1 January 1973 are included in addition to data from Belgium, the Federal Republic of Germany, France, Italy, Luxembourg and the Netherlands. The results presented in this report cover the years 1973 and 1974 for air deposition and surface water and the years 1972, 1973 and 1974 for milk

  6. Introduction of Flame Atomic Absorption Spectrometry (FAAS) For River Water Samples Analysis

    International Nuclear Information System (INIS)

    Shakirah Abd Shukor; Mohd Suhaimi Hamzah; Shamsiah Abdul Rahman

    2015-01-01

    Metal contamination in water is a major component in the determination of water quality monitoring. In spite of the viability of several other metal ion analysis techniques for river water, atomic absorption spectroscopy (AAS) method is most commonly used due to the reproducibility results, short analysis time, cost effective, lower level detection and robust. Therefore, this article gives an overview on the principles, instrumentation techniques, sample preparations, instrument calibration and data analysis in a simple manner for beginner. (author)

  7. The Baltic Sea Experiment (BALTEX): A European contribution to the investigation of the energy and water cycle over a large drainage basin

    DEFF Research Database (Denmark)

    Raschke, E.; Meywerk, J.; Warrach, K.

    2001-01-01

    The Baltic Sea Experiment (BALTEX) is one of the five continental-scale experiments of the Global Energy and Water Cycle Experiment (GEWEX). More than 50 research groups from 14 European countries are participating in this project to measure and model the energy and water cycle over the large...... drainage basin of the Baltic Sea in northern Europe. BALTEX aims to provide a better understanding of the processes of the climate system and to improve and to validate the water cycle in regional numerical models for weather forecasting and climate studies. A major effort is undertaken to couple...

  8. External quality control in ground-water sampling and analysis at the Hanford Site

    International Nuclear Information System (INIS)

    Hall, S.H.; Juracich, S.P.

    1991-11-01

    At the US Department of Energy's Hanford Site, external Quality Control (QC) for ground-water monitoring is extensive and has included routine submittal of intra- and interlaboratory duplicate samples, blind samples, and several kinds of blank samples. Examination of the resulting QC data for nine of the constituents found in ground water at the Hanford Site shows that the quality of analysis has generally been within the expectations of precision and accuracy that have been established by the US Environmental Protection Agency (EPA). The constituents subjected to review were nitrate, chromium, sodium, fluoride, carbon tetrachloride, tritium, ammonium, trichloroethylene, and cyanide. Of these, the fluoride measurements were notable exceptions and were poor by EPA standards. The review has shown that interlaboratory analysis of duplicate samples yields the most useful QC data for evaluating laboratory performance in determining commonly encountered constituents. For rarely encountered constituents, interlaboratory comparisons may be augmented with blind samples (synthetic samples of known composition). Intralaboratory comparisons, blanks, and spikes should be generally restricted to studies of suspected or known sample contamination and to studies of the adequacy of sampling and analytical procedures

  9. Defining an optimum pumping-time requirement for sampling ground-water wells on the Hanford site

    International Nuclear Information System (INIS)

    Scharnhorst, N.L.

    1982-04-01

    The objective was to determine the optimum time period necessary to pump water from a well before a representative sample of the ground water can be obtained. It was assumed that a representative sample has been collected if the concentration of chemical parameters is the same in a number of samples taken consecutively, so that the concentration of parameters does not vary with time of collection. Ground-water samples used in this project were obtained by pumping selected wells on the Hanford Site. At each well, samples were taken at two minute intervals, and on each sample various chemical analyses were performed. Samples were checked for pH, sulfate, iron, specific conductivity, chloride, nitrate and alkalinity. The data showed that pH, alkalinity, sulfate and specific conductivity levels stabilized almost immediately after pumping of the well began. In many wells, the chloride and nitrate levels were unstable throughout the 38-minute sampling period. Iron levels, however, did not behave in either fashion. The concentration of iron in the samples was high when pumping began but dropped rapidly as pumping continued. The best explanation for this is that iron is flushed from the sides of the casing into the well when pumping begins. After several minutes of pumping, most of the dissolved iron is washed from the well casing and the iron concentration reaches a stable plateau representative of the iron concentration in the ground water.Since iron concentration takes longest to stabilize, the optimum pumping time for a well is based on the iron stabilization time for that well

  10. Developing the European Center of Competence on VVER-Type Nuclear Power Reactors

    Science.gov (United States)

    Geraskin, Nikolay; Pironkov, Lyubomir; Kulikov, Evgeny; Glebov, Vasily

    2017-01-01

    This paper presents the results of the European educational projects CORONA and CORONA-II which are dedicated to preserving and further developing nuclear knowledge and competencies in the area of VVER-type nuclear power reactors technologies (Water-Water Energetic Reactor, WWER or VVER). The development of the European Center of Competence for…

  11. Heavy Metals in Salt and Water Samples from Maharloo Lake and their Comparison with Metal Concentrations in Samples from Sirjan, Lar, and Firoozabad Salt Mines

    Directory of Open Access Journals (Sweden)

    Farahnaz Sabet

    2015-03-01

    Full Text Available Maharloo Lake is one of the most important water ecosystems in Iran, which is nowadays exposed to multiple risks and threats due to poor water management, salt extraction, and heavy metal pollution. In this study, the concentrations of such heavy metals as chromium, copper, zinc, arsenic, cadmium, and lead in both water and salt samples collected from areas in the north and south of the lake were determined by atomic absorption (AA-670G after the samples had been digested. Results showed that metal concentrations in the salt samples taken from both the northern and southern areas had identical mean values in the order of Cr> Cu> As> Cd> Pb. An almost similar pattern was detected in metal concentrations in water samples taken from the same areas but with a slight difference in the way they were ordered (Cr> Cu> As> Pb> Cd. It was found that both water and salt samples collected from the northern areas had higher metal concentrations, except for that of Pb which was slightly lower. Comparison of the mean values of metal concentrations in the Salt Lake and those of Sirjan, Lar, and Firoozabad salt mines revealed that copper, cadmium, and lead had their highest concentrations in the Salt Lake while arsenic and chromium recorded their highest values in samples taken from Lar and Firoozabad salt mines, respectively. Based on these findings, it may be concluded that the increased metal concentrations observed in samples from both northern and southern areas of the lake are due to the sewage and effluents from urban, industrial, and hospital sources in Shiraz disposed into the lake as well as such other human activities as farming in the areas around the lake, especially in the northern stretches. These observations call for preventive measures to avoid further water quality degradation in the area.

  12. Characterization samples of Tigris river water treated with nano colloidal silver (physically, chemically, microbiologically)

    International Nuclear Information System (INIS)

    Dumboos, H. I.; Beden, S. J.; Zouari, K.; Chkir, N.; Ahmed, H. A.

    2012-12-01

    Many researches of using nano silver in purification of drinking water from bacteria and its effect on stan dared properties as drinking water were established. Two stages accomplished in these projects. First stage include preparation of colloidal silver with characterization process and prepare water samples through sedimentation, filtration process, PH and turbidity measure then treated with colloidal silver in volume ratio (0.1-Λ) ml/100ml. The second stage represent select the better results from stage one and take samples to determine the standard characterization values with chemical, physical and microbiological taste. Results will be compared with Iraq standard certification. (Author)

  13. DETERMINATION OF ORGANOCHLORINE PESTICIDES IN DRINKING WATERS SAMPLED FROM CLUJ AND HUNEDOARA COUNTIES

    Directory of Open Access Journals (Sweden)

    MARIA-ELISABETA LOVÁSZ

    2011-03-01

    Full Text Available Determination of organochlorine pesticides in drinking waterssampled from Cluj and Hunedoara counties. Pesticides are found scattered indifferent environmental factors (water, air, soil wherefrom they are drawn off byvegetal and animal organisms. Water pollution by pesticides results from the plantprotection products industry and also from massive application of these resourcesin agriculture and other branches of economy. Pesticides can reach surface wateralong with dripping waters and by infiltration may reach the groundwater layers,organochlorine pesticides are most often found in the water sources (dieldrin,endrin, DDT, aldrin, lindane, heptachlor, etc. due to their increased persistence inthe external environment. This study followed up the determination oforganochlorine pesticides in 14 drinking water samples collected from the outputof water treatment plants in Cluj and Hunedoara counties that process surfacewater and deep-water sources. For identification of organochlorine pesticides, thegas chromatographic method after liquid-liquid extraction was used, by a gascromatograph Shimadzu GC 2010 with detector ECD (Electron CaptureDetection. There were not detected higher values than the method detection limit(0.01 μg/l in the drinking water samples collected and analyzed for both totalorganochlorine pesticides and components, which were well below the maximumconcentration admitted by Law 452/2002 regarding drinking water quality. Resultsare correlated with the sanitary protection areas for water sources and with the useof agricultural lands in the area. The solution to reduce risk of pesticides use isecological agriculture , which gains increasingly more ground in Romania too.

  14. Novel concepts for preparation of reference materials as whole water samples for priority substances at nanogram-per-liter level using model suspended particulate matter and humic acids

    NARCIS (Netherlands)

    Elordui-Zapatarietxe, S.; Fettig, I.; Philipp, R.; Gantois, F.; Lalère, B.; Swart, C.; Petrov, P.; Goenaga-Infante, H.; Vanermen, G.; Boom, G.; Emteborg, H.

    2015-01-01

    One of the unresolved issues of the European Water Framework Directive is the unavailability of realistic water reference materials for the organic priority pollutants at low nanogram-per-liter concentrations. In the present study, three different types of ready-to-use water test materials were

  15. Physiological response of wild dugongs (Dugong dugon) to out-of-water sampling for health assessment

    Science.gov (United States)

    Lanyon, Janet M.; Sneath, Helen L.; Long, Trevor; Bonde, Robert K.

    2010-01-01

    The dugong (Dugong dugon) is a vulnerable marine mammal with large populations living in urban Queensland waters. A mark-recapture program for wild dugongs has been ongoing in southern Queensland since 2001. This program has involved capture and in-water sampling of more than 700 dugongs where animals have been held at the water surface for 5 min to be gene-tagged, measured, and biopsied. In 2008, this program expanded to examine more comprehensively body condition, reproductive status, and the health of wild dugongs in Moreton Bay. Using Sea World's research vessel, captured dugongs were lifted onto a boat and sampled out-of-water to obtain accurate body weights and morphometrics, collect blood and urine samples for baseline health parameters and hormone profiles, and ultrasound females for pregnancy status. In all, 30 dugongs, including two pregnant females, were sampled over 10 d and restrained on deck for up to 55 min each while biological data were collected. Each of the dugongs had their basic temperature-heart rate-respiration (THR) monitored throughout their period of handling, following protocols developed for the West Indian manatee (Trichechus manatus). This paper reports on the physiological response of captured dugongs during this out-of-water operation as indicated by their vital signs and the suitability of the manatee monitoring protocols to this related sirenian species. A recommendation is made that the range of vital signs of these wild dugongs be used as benchmark criteria of normal parameters for other studies that intend to sample dugongs out-of-water.

  16. Heterogeneity of the environmental regulation of industrial wastewater: European wineries.

    Science.gov (United States)

    Román-Sánchez, Isabel M; Aznar-Sánchez, José A; Belmonte-Ureña, Luis J

    2015-01-01

    The European legislation of the pollution of industrial wastewater shows a high degree of heterogeneity. This fact implies that there is a market failure with relevant consequences. Within the European Union, each Member State performs a specific transposition of the Water Framework Directive 2000/60. The member states introduce different sanitation fees to correct water pollution. In this paper, the case of the European wine industry is analyzed. It studies the sanitation fees of the five major wine producing countries: France, Italy, Spain, Germany and Portugal. Results show significant differences among the wastewater fees and the study reveals how such heterogeneity leads to relevant market distortions. The research concludes that more homogeneous environmental regulation would promote more sustainable wine production processes with more efficient water management and purification systems, as well as the introduction of cutting edge technologies.

  17. Low incidence of clonality in cold water corals revealed through the novel use of a standardized protocol adapted to deep sea sampling

    Science.gov (United States)

    Becheler, Ronan; Cassone, Anne-Laure; Noël, Philippe; Mouchel, Olivier; Morrison, Cheryl L.; Arnaud-Haond, Sophie

    2017-11-01

    Sampling in the deep sea is a technical challenge, which has hindered the acquisition of robust datasets that are necessary to determine the fine-grained biological patterns and processes that may shape genetic diversity. Estimates of the extent of clonality in deep-sea species, despite the importance of clonality in shaping the local dynamics and evolutionary trajectories, have been largely obscured by such limitations. Cold-water coral reefs along European margins are formed mainly by two reef-building species, Lophelia pertusa and Madrepora oculata. Here we present a fine-grained analysis of the genotypic and genetic composition of reefs occurring in the Bay of Biscay, based on an innovative deep-sea sampling protocol. This strategy was designed to be standardized, random, and allowed the georeferencing of all sampled colonies. Clonal lineages discriminated through their Multi-Locus Genotypes (MLG) at 6-7 microsatellite markers could thus be mapped to assess the level of clonality and the spatial spread of clonal lineages. High values of clonal richness were observed for both species across all sites suggesting a limited occurrence of clonality, which likely originated through fragmentation. Additionally, spatial autocorrelation analysis underlined the possible occurrence of fine-grained genetic structure in several populations of both L. pertusa and M. oculata. The two cold-water coral species examined had contrasting patterns of connectivity among canyons, with among-canyon genetic structuring detected in M. oculata, whereas L. pertusa was panmictic at the canyon scale. This study exemplifies that a standardized, random and georeferenced sampling strategy, while challenging, can be applied in the deep sea, and associated benefits outlined here include improved estimates of fine grained patterns of clonality and dispersal that are comparable across sites and among species.

  18. Determination of 222Rn in water samples from wells and springs in Tokyo by a modified integral counting method

    International Nuclear Information System (INIS)

    Homma, Y.; Murase, Y.; Handa, K.; Murakami, I.

    1997-01-01

    222 Rn in 2L-water samples was extracted with 30 mL toluene, and 21 mL of the toluene solution was transferred into a liquid scintillation vial, in which PPO - 2,5-diphenyloxazole was placed in advance. The total activity of 222 Rn in the water sample was calculated based on the Ostwald's coefficient of solubilities of 222 Rn in toluene and water at the temperature of the sample water and the volume of water and toluene. About 40% of 222 Rn dissolved in 2L-water sample can be collected. After allowing to stand for 3.5 h, the equilibrium mixture of 222 Rn and its daughters was measured with an Aloka liquid scintillation spectrometer using a modified integral counting method which extrapolates the integral counting curve not to the zero pulse-height, but to the zero detection threshold, an average energy required to produce a measurable pulse, of the liquid scintillation spectrometer. The general method which agitates water sample (usually about 10 mL) with a liquid scintillation cocktail is practical when the activity of 222 Rn is high. By adding 10 mL of water sample, however, it is possible also to add variable amounts of quencher. In some cases water sample is preserved with nitric acid. The slope of the integral counting rate curve increases as quench level of the sample increases. Therefore, it is clear that the modified integral counting method gives more accurate 222 Rn concentrations for water samples of strong quench than the conventional integral counting method. 222 Rn sample of 0.2 Bq/L can be determined within an overall uncertainty of 3.1%

  19. Uranium and coexisting element behaviour in surface waters and associated sediments with varied sampling techniques used for uranium exploration

    International Nuclear Information System (INIS)

    Wenrich-Verbeek, K.J.

    1977-01-01

    Optimum sampling methods in surface water and associated sediments for use in uranium exploration are being studied at thirty sites in Colorado, New Mexico, Arizona and Utah. For water samples, filtering is recommended to increase sample homogeneity and reproducibility because for most elements studied water samples which were allowed to remain unfiltered until time of analysis contained higher concentrations than field-filtered samples of the same waters. Acidification of unfiltered samples resulted in still higher concentrations. This is predominantly because of leaching of the elements from the suspended fraction. U in water correslates directly with Ca, Mg, Na, K, Ba, B, Li and As. In stream sediments, U and other trace elements are concentrated in the finer size fractions. Accordingly, in prospecting, grain size fractions less than 90 μm (170 mesh) should be analyzed for U. A greater number of elements (21) show a significant positive correlation with U in stream sediments than in water. Results have revealed that anomalous concentrations of U found in water may not be detected in associated sediments and vice versa. Hence, sampling of both surface water and coexisting sediment is strongly recommended

  20. Inter-laboratory exercise on steroid estrogens in aqueous samples

    DEFF Research Database (Denmark)

    Heath, E.; Kosjek, T.; Andersen, Henrik Rasmus

    2010-01-01

    to the analytical techniques applied, the accuracy and reproducibility of the analytical methods and the nature of the sample matrices. Overall, the results obtained in this inter-laboratory exercise reveal a high level of competence among the participating laboratories for the detection of steroid estrogens......An inter-laboratory comparison exercise was organized among European laboratories, under the aegis of EU COST Action 636: "Xenobiotics in Urban Water Cycle" The objective was to evaluate the performance of testing laboratories determining "Endocrine Disrupting Compounds" (EDC) in various aqueous...

  1. Radioactivity in north European waters: report of Working Group 2 of CEC project MARINA

    International Nuclear Information System (INIS)

    Camplin, W.C.; Aarkrog, A.

    1989-01-01

    The primary objective of Working Group 2 of Project MARINA was to consider recent measurements of environmental radioactivity in north European waters and to use this, and other information, to report likely magnitude of doses to the critical group from marine pathways. The monitoring data were supplemented, where appropriate, with predictions from simple models. The major sources of radioactivity studied were as follows: (i) liquid wastes from nuclear fuel reprocessing plants, (Sellafield, Dounreay, Cap de la Hague); (ii) liquid wastes from nuclear power plants and other major nuclear industry sites, (including Belgium, Denmark, France, Finland, GDR, FDR, Netherlands, Sweden, UK, USSR); (iii) solid waste disposal in the deep north-east Atlantic; (iv) fallout from Chernobyl; and (v) naturally-occurring radionuclides. (author)

  2. Emerging genotype (GGIIb) of norovirus in drinking water, Sweden.

    Science.gov (United States)

    Nygård, Karin; Torvén, Maria; Ancker, Camilla; Knauth, Siv Britt; Hedlund, Kjell-Olof; Giesecke, Johan; Andersson, Yvonne; Svensson, Lennart

    2003-12-01

    From May through June 2001, an outbreak of acute gastroenteritis that affected at least 200 persons occurred in a combined activity camp and conference center in Stockholm County. The source of illness was contaminated drinking water obtained from private wells. The outbreak appears to have started with sewage pipeline problems near the kitchen, which caused overflow of the sewage system and contaminated the environment. While no pathogenic bacteria were found in water or stools specimens, norovirus was detected in 8 of 11 stool specimens and 2 of 3 water samples by polymerase chain reaction. Nucleotide sequencing of amplicons from two patients and two water samples identified an emerging genotype designated GGIIb, which was circulating throughout several European countries during 2000 and 2001. This investigation documents the first waterborne outbreak of viral gastroenteritis in Sweden, where nucleotide sequencing showed a direct link between contaminated water and illness.

  3. Studies of radon mitigation in well water by aeration

    International Nuclear Information System (INIS)

    Mafra, Karina Cristina; Paschuk, Sergei A.; Denyak, Valeriy; Reque, Marilson; Correa, Janine Nicolosi; Barbosa, Laercio

    2011-01-01

    The 222 Rn concentration in natural water in different countries usually is about few Bq/L and is the subject of the National legislation as well as International norms and recommendations. The United States Environmental Protection Agency (USEPA) established a limit of 11.1 Bq/L for the radon level in drinking water and this limit is considered as guideline in Canada and many countries of the European Union. This work presents the results of study of radon ( 222 Rn) concentration reduction in well water using the aeration process developed at the Laboratory of Applied Nuclear Physics of the Federal University of Technology (UTFPR). The water samples were collected from a well at Pinheirinho region of Curitiba in 2011. Experimental setup was based on the Radon Monitor (AlphaGUARD). The 222 Rn concentration was analyzed using the software DataEXPERT by Genitron Instruments, taking into account the volume of water sample, its temperature, atmospheric pressure and the total volume of the air in the vessels. Initial concentration of radon in water samples was 28,67 Bq/L which is bigger than maximum concentration recommended by USEPA. The mitigation was performed by means of diffusion aeration of water samples of 15L during the time interval of 24 hours following a period of 4 days. The efficiency of aeration mitigation was controlled by comparing the activity of radon in aerated water with reference water samples that were not aerated. Obtained results show very satisfactory decrease of 222 Rn activity in water samples even after few hours of intense aeration. (author)

  4. Evaluation of different conditions and culture media for the recovery of Aeromonas spp. from water and shellfish samples.

    Science.gov (United States)

    Latif-Eugenín, F; Beaz-Hidalgo, R; Figueras, M J

    2016-09-01

    To perform a comparative study for determining the optimum culture method (direct plating or enrichment) and medium (ampicillin dextrin agar (ADA), starch ampicillin agar (SAA), bile salts irgasan brilliant green modified (BIBG-m)) for recovering Aeromonas species from water and shellfish samples. By direct culture, Aeromonas was detected in 65% (13/20) of the water samples and in 54·5% (6/11) of the shellfish samples. However, when a pre-enrichment step was included, the number of positive water samples increased to 75% (15/20) and the ones of shellfish to 90·1% (10/11). The enriched culture significantly favoured (P culture medium for detecting Aeromonas from water was ADA. However, no differences were observed in the case of shellfish samples (P > 0·05). Isolation of Aeromonas media from water was favoured (P culture method and medium used influenced the recovery of some Aeromonas species from water and shellfish samples. This fact should be considered in future prevalence studies to avoid overestimating the above mentioned Aeromonas species. © 2016 The Society for Applied Microbiology.

  5. [Optimization of solid-phase extraction for enrichment of toxic organic compounds in water samples].

    Science.gov (United States)

    Zhang, Ming-quan; Li, Feng-min; Wu, Qian-yuan; Hu, Hong-ying

    2013-05-01

    A concentration method for enrichment of toxic organic compounds in water samples has been developed based on combined solid-phase extraction (SPE) to reduce impurities and improve recoveries of target compounds. This SPE method was evaluated in every stage to identify the source of impurities. Based on the analysis of Waters Oasis HLB without water samples, the eluent of SPE sorbent after dichloromethane and acetone contributed 85% of impurities during SPE process. In order to reduce the impurities from SPE sorbent, soxhlet extraction of dichloromethane followed by acetone and lastly methanol was applied to the sorbents for 24 hours and the results had proven that impurities were reduced significantly. In addition to soxhlet extraction, six types of prevalent SPE sorbents were used to absorb 40 target compounds, the lgK(ow) values of which were within the range of 1.46 and 8.1, and recovery rates were compared. It was noticed and confirmed that Waters Oasis HLB had shown the best recovery results for most of the common testing samples among all three styrenedivinylbenzene (SDB) polymer sorbents, which were 77% on average. Furthermore, Waters SepPak AC-2 provided good recovery results for pesticides among three types of activated carbon sorbents and the average recovery rates reached 74%. Therefore, Waters Oasis HLB and Waters SepPak AC-2 were combined to obtain a better recovery and the average recovery rate for the tested 40 compounds of this new SPE method was 87%.

  6. The correlation of arsenic levels in drinking water with the biological samples of skin disorders

    Energy Technology Data Exchange (ETDEWEB)

    Kazi, Tasneem Gul [Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan)], E-mail: tgkazi@yahoo.com; Arain, Muhammad Balal [Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan)], E-mail: bilal_ku2004@yahoo.com; Baig, Jameel Ahmed [Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan)], E-mail: jab_mughal@yahoo.com; Jamali, Muhammad Khan [Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan)], E-mail: mkhanjamali@yahoo.com; Afridi, Hassan Imran [Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan)], E-mail: hassanimranafridi@yahoo.com; Jalbani, Nusrat [Pakistan Council for Scientific and Industrial Research, University Road Karachi-75280 (Pakistan)], E-mail: nusratjalbani_21@yahoo.com; Sarfraz, Raja Adil [Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan)], E-mail: rajaadilsarfraz@gmail.com; Shah, Abdul Qadir [Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan)], E-mail: aqshah07@yahoo.com; Niaz, Abdul [Center of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080 (Pakistan)], E-mail: niazchemist2k6@yahoo.com

    2009-01-15

    Arsenic (As) poisoning has become a worldwide public health concern. The skin is quite sensitive to As and skin lesions are the most common and earliest nonmalignant effects associated to chronic As exposure. In 2005-2007, a survey was carried out on surface and groundwater arsenic contamination and relationships between As exposure via the drinking water and related adverse health effects (melanosis and keratosis) on villagers resides on the banks of Manchar lake, southern part of Sindh, Pakistan. We screened the population from arsenic-affected villages, 61 to 73% population were identified patients suffering from chronic arsenic toxicity. The effects of As toxicity via drinking water were estimated by biological samples (scalp hair and blood) of adults (males and females), have or have not skin problem (n = 187). The referent samples of both genders were also collected from the areas having low level of As (< 10 {mu}g/L) in drinking water (n = 121). Arsenic concentration in drinking water and biological samples were analyzed using electrothermal atomic absorption spectrometry. The range of arsenic concentrations in lake surface water was 35.2-158 {mu}g/L, which is 3-15 folds higher than World Health Organization [WHO, 2004. Guidelines for drinking-water quality third ed., WHO Geneva Switzerland.]. It was observed that As concentration in the scalp hair and blood samples were above the range of permissible values 0.034-0.319 {mu}g As/g for hair and < 0.5-4.2 {mu}g/L for blood. The linear regressions showed good correlations between arsenic concentrations in water versus hair and blood samples of exposed skin diseased subjects (R{sup 2} = 0.852 and 0.718) as compared to non-diseased subjects (R{sup 2} = 0.573 and 0.351), respectively.

  7. European perspectives on regional estimates of standing water bodies and the relevance of man-made ponds

    Science.gov (United States)

    Terasmaa, Jaanus; Bartout, Pascal; Marzecova, Agata; Touchart, Laurent; Koff, Tiiu; Choffel, Quentin; Kapanen, Galina; Maleval, Véronique; Millot, Camille; Qsair, Zoubida; Vandel, Egert

    2015-04-01

    Until recently, the small water bodies have been disregarded in the environmental management and protection policies. For example, the European Water Framework Directive 2000/60/EC proposes the threshold surface area of water bodies for typology and reporting as 50 ha. The inventories on state level or scientific studies took into account smaller water bodies (e.g. third higher than officially registered inventories. Also, in Estonia, the water bodies with a surface area below 1 ha are almost 50 times more abundant than those above 1 ha and 92% of all standing water bodies are smaller than 0.2 ha. Using the OpenStreetMap database we will discuss the differences between global inventories and EU-level analysis. We will show the alternative regional estimates of water bodies with the surface size threshold limit 0.01 ha which will illustrate the quantitative importance of very small often man-made ponds, which are however, abundant cultural heritage in many parts of Europe. Secondly, by comparing detailed national inventories compiled for France and Estonia, we will introduce usefulness of the the 'local to global' approach in which the local databases may significantly strengthen the precision of the regional (EU) level analysis. Overall, we will disss that all standing water bodies - including small and man-made ponds - play an important role in ecosystem services and require careful management to avoid hydrological and environmental deterioration. References: Verpoorter et al. (2014) Geophysical Research Letters, 41. Bartout & Touchart,(2013) Annales de Géographie, 691. Downing et al., (2006) Limnology and Oceanography, 51(5). Kuusisto & Raatikainen, (1988) Terra, 102. Meybeck, (1995) in Lerman et al., Physics and chemistry of lakes. Rjanžin, (2005) Priroda, 4.

  8. Variation of the 18O/16O ratio in water samples from branches

    International Nuclear Information System (INIS)

    Foerstel, H.; Huetzen, H.

    1979-06-01

    The studies of the water turnover of plants may use the labelling of water by its natural variation of the 18 O/ 16 O ratio. The basic value of such a study is the isotope ratio in soil water, which is represented by the 18 O/ 16 O ratio in water samples from stem and branches, too. During the water transport from the soil water reservoir to the leaves of trees, no fractionation of the oxygen isotopes occurs. The oxygen isotope ratio within a single twig varies about +- 0 / 00 (variation given as standard deviation of the delta-values), within the stem of a large tree about +- 2 0 / 00 . The results of water from stems of different trees at the site of the Nuclear Research Center Juelich scatter about +- 1 0 / 00 . The delta-values from a larger area (Rur valley-Eifel hills-Mosel valley), which were collected in October 1978 during the end of the vegetation period, showed a standard deviation between +- 2.2 (Rur valley) and +- 3.6 0 / 00 (Eifel hills). The 18 O/ 16 O-delta-values of a beech wood from Juelich site are in the range of - 7.3 and - 10.1 0 / 00 (mean local precipitation 1974 - 1977: - 7.4 0 / 00 ). At the hill site near Cologne (Bergisches Land, late September 1978) we observed an oxygen isotope ratio of - 9.1 0 / 00 (groundwater at the neighbourhood between - 7.6 and 8.7 0 / 00 ). In October 1978 at an area from the Netherlands to the Mosel valley we found delta-values of branch water between - 13.9 (lower Ruhr valley) and - 13.1 (Eifel hills to Mosel valley) in comparison to groundwater samples from the same region: - 7.55 and - 8.39. There was no significant difference between delta-values from various species or locations within this area. Groundwater samples should normally represent the 18 O/ 16 O ratio of local precipitation. The low delta-values of branch water could be due to the rapid uptake of precipitation water of low 18 O content in autumn to the water transport system of plants. (orig.) [de

  9. Spectrophotometric determination of mercury in water samples after preconcentration using dispersive liquid-liquid microextraction.

    Science.gov (United States)

    Lemos, Valfredo Azevedo; dos Santos, Liz Oliveira; Silva, Eldevan dos Santos; Vieira, Emanuel Vitor dos Santos

    2012-01-01

    A simple method for the determination of mercury in water samples after preconcentration using dispersive liquid-liquid microextraction is described. The procedure is based on the extraction of mercury in the form of a complex and its subsequent determination by spectrophotometry. The complex is formed between Hg(II) and 2-(2-benzothiazolylazo)-p-cresol. The detection at 650 nm is performed directly in the metal-rich phase, which is spread on a triacetylcellulose membrane. The method eliminates the need to use a cuvet or large quantities of samples and reagents. The parameters that influence the preconcentration were studied, and the analytical characteristics were determined. The enrichment factor and the consumptive index for this method were 64 and 0.16 mL, respectively. The LOD (3.3 microg/L) and LOQ (11.1 microg/L) were also determined. The accuracy of the method was tested by the determination of mercury in certified reference materials BCR 397 (Human Hair) and SRM 2781 (Domestic Sludge). The method was applied to the determination of mercury in samples of drinking water, sea water, and river water.

  10. Determination of geostatistically representative sampling locations in Porsuk Dam Reservoir (Turkey)

    Science.gov (United States)

    Aksoy, A.; Yenilmez, F.; Duzgun, S.

    2013-12-01

    Several factors such as wind action, bathymetry and shape of a lake/reservoir, inflows, outflows, point and diffuse pollution sources result in spatial and temporal variations in water quality of lakes and reservoirs. The guides by the United Nations Environment Programme and the World Health Organization to design and implement water quality monitoring programs suggest that even a single monitoring station near the center or at the deepest part of a lake will be sufficient to observe long-term trends if there is good horizontal mixing. In stratified water bodies, several samples can be required. According to the guide of sampling and analysis under the Turkish Water Pollution Control Regulation, a minimum of five sampling locations should be employed to characterize the water quality in a reservoir or a lake. The European Union Water Framework Directive (2000/60/EC) states to select a sufficient number of monitoring sites to assess the magnitude and impact of point and diffuse sources and hydromorphological pressures in designing a monitoring program. Although existing regulations and guidelines include frameworks for the determination of sampling locations in surface waters, most of them do not specify a procedure in establishment of monitoring aims with representative sampling locations in lakes and reservoirs. In this study, geostatistical tools are used to determine the representative sampling locations in the Porsuk Dam Reservoir (PDR). Kernel density estimation and kriging were used in combination to select the representative sampling locations. Dissolved oxygen and specific conductivity were measured at 81 points. Sixteen of them were used for validation. In selection of the representative sampling locations, care was given to keep similar spatial structure in distributions of measured parameters. A procedure was proposed for that purpose. Results indicated that spatial structure was lost under 30 sampling points. This was as a result of varying water

  11. European Marine Observation and Data Network EMODnet Physics

    Directory of Open Access Journals (Sweden)

    Antonio Novellino

    2014-10-01

    Full Text Available Recently the European Commission undertook steps towards a European Marine Observation and Data Network (EMODnet in order to standardize method for observing and assessing the grade of the Member States seas and improve access to high quality data. Since 2008-2009, European Commission, represented by the Directorate-General for Maritime Affairs and Fisheries (DG MARE, is running several service contracts for creating pilot thematic components of the ur-EMODNET: Biology, Bathymetry, Chemistry, Geology, Habitats, and Physics.The existing EMODnet-Physics portal (www.emodnet-physics.eu is based on a strong collaboration between EuroGOOS member institutes and its regional operational oceanographic systems (ROOSs, and the National Oceanographic Data Centres (NODCs, and it is a marine observation information system. It includes systems for physical data from the whole Europe (wave height andperiod, temperature of the water column, wind speed and direction, salinity of the water column, horizontal velocity of the water column, light attenuation, and sea level provided mainly by fixed stations and ferry-box platforms, discovering related data sets (both near real time and historical data sets, viewing and downloading of the data from about 2100 platforms (www.emodnetphysics.eu/map and thus contributing towards the definition of an operational European Marine Observation and Data Network (EMODnet.

  12. Paper-Based Analytical Device for Zinc Ion Quantification in Water Samples with Power-Free Analyte Concentration

    Directory of Open Access Journals (Sweden)

    Hiroko Kudo

    2017-04-01

    Full Text Available Insufficient sensitivity is a general issue of colorimetric paper-based analytical devices (PADs for trace analyte detection, such as metal ions, in environmental water. This paper demonstrates the colorimetric detection of zinc ions (Zn2+ on a paper-based analytical device with an integrated analyte concentration system. Concentration of Zn2+ ions from an enlarged sample volume (1 mL has been achieved with the aid of a colorimetric Zn2+ indicator (Zincon electrostatically immobilized onto a filter paper substrate in combination with highly water-absorbent materials. Analyte concentration as well as sample pretreatment, including pH adjustment and interferent masking, has been elaborated. The resulting device enables colorimetric quantification of Zn2+ in environmental water samples (tap water, river water from a single sample application. The achieved detection limit of 0.53 μM is a significant improvement over that of a commercial colorimetric Zn2+ test paper (9.7 μM, demonstrating the efficiency of the developed analyte concentration system not requiring any equipment.

  13. The water footprint of agricultural products in European river basins

    International Nuclear Information System (INIS)

    Vanham, D; Bidoglio, G

    2014-01-01

    This work quantifies the agricultural water footprint (WF) of production (WF prod, agr ) and consumption (WF cons, agr ) and the resulting net virtual water import (netVW i, agr ) of 365 European river basins for a reference period (REF, 1996–2005) and two diet scenarios (a healthy diet based upon food-based dietary guidelines (HEALTHY) and a vegetarian (VEG) diet). In addition to total (tot) amounts, a differentiation is also made between the green (gn), blue (bl) and grey (gy) components. River basins where the REF WF cons, agr, tot exceeds the WF prod, agr, tot (resulting in positive netVW i, agr, tot values), are found along the London–Milan axis. These include the Thames, Scheldt, Meuse, Seine, Rhine and Po basins. River basins where the WF prod, agr, tot exceeds the WF cons, agr, tot are found in Western France, the Iberian Peninsula and the Baltic region. These include the Loire, Ebro and Nemunas basins. Under the HEALTHY diet scenario, the WF cons, agr, tot of most river basins decreases (max −32%), although it was found to increase in some basins in northern and eastern Europe. This results in 22 river basins, including the Danube, shifting from being net VW importers to being net VW exporters. A reduction (max −46%) in WF cons, agr, tot is observed for all but one river basin under the VEG diet scenario. In total, 50 river basins shift from being net VW importers to being net exporters, including the Danube, Seine, Rhone and Elbe basins. Similar observations are made when only the gn + bl and gn components are assessed. When analysing only the bl component, a different river basin pattern is observed. (letters)

  14. Effect of Water-Glass Coating on HA and HA-TCP Samples for MSCs Adhesion, Proliferation, and Differentiation

    Directory of Open Access Journals (Sweden)

    Indu Bajpai

    2016-01-01

    Full Text Available Ca-P and silicon based materials have become very popular as bone tissue engineering materials. In this study, water-glass (also known as sodium silicate glass was coated on sintered hydroxyapatite (HA and HA-TCP (TCP stands for tricalcium phosphate samples and subsequently heat-treated at 600°C for 2 hrs. X-rays diffraction showed the presence of β- and α-TCP phases along with HA in the HA-TCP samples. Samples without coating, with water-glass coating, and heat-treated after water-glass coating were used to observe the adhesion and proliferation response of bone marrow derived-mesenchymal stem cells (MSCs. Cell culture was carried out for 4 hrs, 1 day, and 7 days. Interestingly, all samples showed similar response for cell adhesion and proliferation up to 7-day culture but fibronectin, E-cadherin, and osteogenic differentiation related genes (osteocalcin and osteopontin were significantly induced in heat-treated water-glass coated HA-TCP samples. A water-glass coating on Ca-P samples was not found to influence the cell proliferation response significantly but activated some extracellular matrix genes and induced osteogenic differentiation in the MSCs.

  15. Adaptive Kalman Filter Based on Adjustable Sampling Interval in Burst Detection for Water Distribution System

    Directory of Open Access Journals (Sweden)

    Doo Yong Choi

    2016-04-01

    Full Text Available Rapid detection of bursts and leaks in water distribution systems (WDSs can reduce the social and economic costs incurred through direct loss of water into the ground, additional energy demand for water supply, and service interruptions. Many real-time burst detection models have been developed in accordance with the use of supervisory control and data acquisition (SCADA systems and the establishment of district meter areas (DMAs. Nonetheless, no consideration has been given to how frequently a flow meter measures and transmits data for predicting breaks and leaks in pipes. This paper analyzes the effect of sampling interval when an adaptive Kalman filter is used for detecting bursts in a WDS. A new sampling algorithm is presented that adjusts the sampling interval depending on the normalized residuals of flow after filtering. The proposed algorithm is applied to a virtual sinusoidal flow curve and real DMA flow data obtained from Jeongeup city in South Korea. The simulation results prove that the self-adjusting algorithm for determining the sampling interval is efficient and maintains reasonable accuracy in burst detection. The proposed sampling method has a significant potential for water utilities to build and operate real-time DMA monitoring systems combined with smart customer metering systems.

  16. Sampling problems and the determination of mercury in surface water, seawater, and air

    International Nuclear Information System (INIS)

    Das, H.A.; van der Sloot, H.A.

    1976-01-01

    Analysis of surface water for mercury comprises the determination of both ionic and organically bound mercury in solution and that of the total mercury content of the suspended matter. Eventually, metallic mercury has to be determined too. Requirements for the sampling procedure are given. A method for the routine determination of mercury in surface water and seawater was developed and applied to Dutch surface waters. The total sample volume is 2500 ml. About 500 ml is used for the determination of the content of suspended matter and the total amount of mercury in the water. The sample is filtered through a bed of previously purified active charcoal at a low flow-rate. The main portion ca. 2000 ml) passes a flow-through centrifuge to separate the solid fraction. One liter is used to separate ''inorganic'' mercury by reduction, volatilization in an airstream and adsorption on active charcoal. The other liter is led through a column of active charcoal to collect all mercury. The procedures were checked with 197 Hg radiotracer both as an ion and incorporated in organic compounds. The mercury is determined by thermal neutron activation, followed by volatilization in a tube furnace and adsorption on a fresh carbon bed. The limit of determination is approximately equal to 1 ng 1 -1 . The rate of desorption from and adsorption on suspended material has been measured as a function of a pH of the solution for Hg +2 and various other ions. It can be concluded that only the procedure mentioned above does not disturb the equilibrium. The separation of mercury from air is obtained by suction of 1 m 3 through a 0.22 μm filter and a charcoal bed. The determination is then performed as in the case of the water samples

  17. Two ;pillars; of cold-water coral reefs along Atlantic European margins: Prevalent association of Madrepora oculata with Lophelia pertusa, from reef to colony scale

    Science.gov (United States)

    Arnaud-Haond, S.; Van den Beld, I. M. J.; Becheler, R.; Orejas, C.; Menot, L.; Frank, N.; Grehan, A.; Bourillet, J. F.

    2017-11-01

    The scleractinian coral Lophelia pertusa has been the focus of deep-sea research since the recognition of the vast extent of coral reefs in North Atlantic waters two decades ago, long after their existence was mentioned by fishermen. These reefs where shown to provide habitat, concentrate biomass and act as feeding or nursery grounds for many species, including those targeted by commercial fisheries. Thus, the attention given to this cold-water coral (CWC) species from researchers and the wider public has increased. Consequently, new research programs triggered research to determine the full extent of the corals geographic distribution and ecological dynamics of ;Lophelia reefs;. The present study is based on a systematic standardised sampling design to analyze the distribution and coverage of CWC reefs along European margins from the Bay of Biscay to Iceland. Based on Remotely Operated Vehicle (ROV) image analysis, we report an almost systematic occurrence of Madrepora oculata in association with L. pertusa with similar abundances of both species within explored reefs, despite a tendency of increased abundance of L. pertusa compared to M. oculata toward higher latitudes. This systematic association occasionally reached the colony scale, with ;twin; colonies of both species often observed growing next to each other when isolated structures were occurring off-reefs. Finally, several ;false chimaera; were observed within reefs, confirming that colonial structures can be ;coral bushes; formed by an accumulation of multiple colonies even at the inter-specific scale, with no need for self-recognition mechanisms. Thus, we underline the importance of the hitherto underexplored M. oculata in the Eastern Atlantic, re-establishing a more balanced view that both species and their yet unknown interactions are required to better elucidate the ecology, dynamics and fate of European CWC reefs in a changing environment.

  18. Sampling analytical tests and destructive tests for quality assurance

    International Nuclear Information System (INIS)

    Saas, A.; Pasquini, S.; Jouan, A.; Angelis, de; Hreen Taywood, H.; Odoj, R.

    1990-01-01

    In the context of the third programme of the European Communities on the monitoring of radioactive waste, various methods have been developed for the performance of sampling and measuring tests on encapsulated waste of low and medium level activity, on the one hand, and of high level activity, on the other hand. The purpose was to provide better quality assurance for products to be stored on an interim or long-term basis. Various testing sampling means are proposed such as: - sampling of raw waste before conditioning and determination of the representative aliquot, - sampling of encapsulated waste on process output, - sampling of core specimens subjected to measurement before and after cutting. Equipment suitable for these sampling procedures have been developed and, in the case of core samples, a comparison of techniques has been made. The results are described for the various analytical tests carried out on the samples such as: - mechanical tests, - radiation resistance, - fire resistance, - lixiviation, - determination of free water, - biodegradation, - water resistance, - chemical and radiochemical analysis. Every time it was possible, these tests were compared with non-destructive tests on full-scale packages and some correlations are given. This word has made if possible to improve and clarify sample optimization, with fine sampling techniques and methodologies and draw up characterization procedures. It also provided an occasion for a first collaboration between the laboratories responsible for these studies and which will be furthered in the scope of the 1990-1994 programme

  19. Water Consumption in European Children: Associations with Intake of Fruit Juices, Soft Drinks and Related Parenting Practices.

    Science.gov (United States)

    Mantziki, Krystallia; Renders, Carry M; Seidell, Jaap C

    2017-05-31

    Background : High intake of fruit juices and soft drinks contributes to excessive weight gain and obesity in children. Furthermore, parenting practices play an important role in the development of children's dietary habits. The way parents play this role in the development of their children's choices of beverages is still unclear. Objectives : To study the associations: (1) of both fruit juices and soft drinks consumption with water consumption of children and (2) The associations between parenting practices towards fruit juices and soft drinks and water consumption of children. Design : Cross-sectional data from 6 to 8 year old children from seven European communities ( n = 1187) were collected. Associations among fruit juices, soft drinks, the respective parenting practices and the child's water consumption were assessed by parental questionnaires. Results : The consumption of water was inversely associated with that of soft drinks but not with the consumption of fruit juices. The child's water intake was favorably influenced when stricter parenting practices towards soft drinks were adopted (e.g., less parental allowance, low home availability and high parental self-efficacy in managing intake). There was less influence observed of parenting practices towards fruit juices. Fruit juices were consumed more often than soft drinks. Conclusions : Low consumption of soft drinks-and not of fruit juices-was associated with high water consumption in children in the current study. Moreover, parenting practices towards both fruit juices and soft drinks were associated with the water intake of the children, irrespective of their socio-economic status.

  20. Detection of Waterborne Protozoa, Viruses, and Bacteria in Groundwater and Other Water Samples in the Kathmandu Valley, Nepal

    Science.gov (United States)

    Haramoto, E.

    2018-03-01

    In this study, the prevalence of various waterborne pathogens in water samples collected in the Kathmandu Valley, Nepal, and the applicability of Escherichia coli as an indicator of pathogen contamination in groundwater were assessed. Fifty-three water samples, including shallow groundwater and river water, were analyzed to examine the presence of protozoan (oo)cysts via fluorescence microscopy and that of viral and bacterial genomes via quantitative PCR. At least one of the seven types of pathogens tested (i.e., Cryptosporidium, Giardia, human adenoviruses, noroviruses of genogroups I and II, group A rotaviruses, and Vibrio cholerae) was detected in 68% (15/22) of the shallow dug well water samples; groundwater in the shallow dug wells was more contaminated compared with that in shallow tube wells (8/15, 53%). River water and sewage samples were contaminated with extremely high concentrations of multiple pathogens, whereas a tap water sample supplied by a water tanker tested positive for human adenoviruses and V. cholerae. The detection of host-specific Bacteroidales genetic markers revealed the effects of human and animal feces on groundwater contamination. The tested pathogens were sometimes detected even in E. coli-negative groundwater samples, indicative of the limitations of using E. coli as an indicator for waterborne pathogens in groundwater.

  1. Die-back of Phragmites australis in European wetlands: an overview of the European Research Programme on Reed Die-Back and Progression (1993-1994)

    NARCIS (Netherlands)

    Van der Putten, W.H.

    1997-01-01

    Reed (Phragmites australis (Cav.) Trin. ex Steudel) is one of the dominant plant species in European land-water ecotones. During the past decades reed belts have died back, especially in central and eastern Europe. The aim of the European Research Programme on Reed Die-back and Progression (EUREED),

  2. Membrane solid-phase extraction: Field application for isolation of polycyclic aromatic hydrocarbons from water samples

    International Nuclear Information System (INIS)

    Furlong, E.T.; Koleis, J.C.; Gates, P.M.

    1995-01-01

    Solid-phase extraction (SPE) membranes (M-SPE) were used to isolate microgram-per-liter to nanogram-per-liter quantities of polycyclic aromatic hydrocarbons (PAH) in 4- to 8-liter ground-water samples from a crude-oil-contaminated ground-water site near Bemidji, Minnesota. The M-SPE method was evaluated (1) under laboratory conditions using reagent water fortified with individual PAH at 1.23 micrograms per liter, and (2) at the Bemidji site. At the site, ground-water samples were processed and PAH isolated using a M-SPE system connected directly to the well pump. Following sample isolation, all M-SPE samples were extracted using dichloromethane and analyzed by gas chromatography-mass spectrometry with selected-ion monitoring. Operationally, the M-SPE method provided a simple means to isolate PAH on site at the wellhead, particularly for anoxic water samples. Acceptable recoveries, ranging from 56 to over 100 percent, were observed for lower molecular weight PAH (naphthalene to pyrene) using the M-SPE method. Recoveries using M-SPE were somewhat lower, but reproducible, for higher molecular weight PAH (chrysene to benzo[ghi]perylene), ranging from 18 to 56 percent. M-SPE provides the capability to collect and field isolate PAH from a sufficiently large number of samples to identify environmental chemical processes occurring at individual compound concentrations of 50 to 1,200 nanograms per liter. Using M-SPE, the potential for facilitated transport of PAH by in situ-derived dissolved organic carbon (DOC) was evaluated at the site. Plots comparing DOC and PAH concentrations indicate that PAH concentrations increase exponentially with linear increases in DOC concentrations

  3. Genetic Population Structure and Demographic History of the Widespread Common Shipworm Teredo navalis Linnaeus 1758 (Mollusca: Bivalvia: Teredinidae in European Waters Inferred from Mitochondrial COI Sequence Data

    Directory of Open Access Journals (Sweden)

    Ronny Weigelt

    2017-06-01

    Full Text Available The first documented scientific reports of the common marine shipworm Teredo navalis (Bivalvia for Central European waters date back to the time between 1700 and 1730 in the Netherlands. During the following centuries there were several irregular mass occurrences reported for both the North Sea and the Baltic Sea. These events were accompanied by massive destruction of wooden ships and coastal protection structures. In this study, the first population analysis of T. navalis is presented with the aim to detect the genetic population structure in the waters of Central Europe. The mtDNA COI (cytochrome c oxidase subunit I locus was found as suitable molecular marker and hence a 675 bp gene fragment was studied. A total of 352 T. navalis specimens from 13 different sampling sites distributed across Central Europe were examined. Subsequently, various population genetic indices including FST values and an AMOVA analysis were applied for the description of the population structure. To visualize the distribution of haplotypes at the different sampling sites two median-joining networks were calculated. In addition, the past demographic structure of the T. navalis population was analyzed, among others by calculating Tajima's D, Fu's F and the mismatch distribution. Finally, all computations of the population genetic indices could not reveal differentiated populations or any kind of distinct population structure in T. navalis. The network analyses revealed “star-like” patterns without differentiated substructures or demes. Therefore, it can be assumed that a sudden expansion of this species took place without any indications of neither a bottleneck nor a founder effect for the study area. The results of this study support the concept of a regional panmictic population in the waters of Central Europe with unhindered migration of individuals (e.g., via pelagic larvae between the various sampling sites as reflected by a high gene flow.

  4. A Numerical Investigation on the Effect of Gas Pressure on the Water Saturation of Compacted Bentonite-Sand Samples

    Directory of Open Access Journals (Sweden)

    Jiang-Feng Liu

    2017-01-01

    Full Text Available In deep geological disposal for high-level radioactive waste, the generated gas can potentially affect the sealing ability of bentonite buffers. There is a competition between water and gas: the former provides sealing by swelling bentonite, and the latter attempts to desaturate the bentonite buffer. Thus, this study focused on numerically modelling the coupling effects of water and gas on the water saturation and sealing efficiency of compacted bentonite-sand samples. Different gas pressures were applied to the top surface of an upper sample, whereas the water pressure on the bottom side of the lower sample was maintained at 4 MPa. The results indicated that gas pressure did not significantly affect the saturation of the bentonite-sand sample until 2 MPa. At 2 MPa, the degree of water saturation of the upper sample was close to 1.0. As the gas pressure increased, this influence was more apparent. When the gas pressure was 6 MPa or higher, it was difficult for the upper sample to become fully saturated. Additionally, the lower sample was desaturated due to the high gas pressure. This indicated that gas pressure played an important role in the water saturation process and can affect the sealing efficiency of bentonite-based buffer materials.

  5. Determination of colloidal and dissolved silver in water samples using colorimetric solid-phase extraction.

    Science.gov (United States)

    Hill, April A; Lipert, Robert J; Porter, Marc D

    2010-03-15

    The increase in bacterial resistance to antibiotics has led to resurgence in the use of silver as a biocidal agent in applications ranging from washing machine additives to the drinking water treatment system on the International Space Station (ISS). However, growing concerns about the possible toxicity of colloidal silver to bacteria, aquatic organisms and humans have led to recently issued regulations by the US EPA and FDA regarding the usage of silver. As part of an ongoing project, we have developed a rapid, simple method for determining total silver, both ionic (silver(I)) and colloidal, in 0.1-1mg/L aqueous samples, which spans the ISS potable water target of 0.3-0.5mg/L (total silver) and meets the US EPA limit of 0.1mg/L in drinking water. The method is based on colorimetric solid-phase extraction (C-SPE) and involves the extraction of silver(I) from water samples by passage through a solid-phase membrane impregnated with the colorimetric reagent DMABR (5-[4-(dimethylamino)benzylidene]rhodanine). Silver(I) exhaustively reacts with impregnated DMABR to form a colored compound, which is quantified using a handheld diffuse reflectance spectrophotometer. Total silver is determined by first passing the sample through a cartridge containing Oxone, which exhaustively oxidizes colloidal silver to dissolved silver(I). The method, which takes less than 2 min to complete and requires only approximately 1 mL of sample, has been validated through a series of tests, including a comparison with the ICP-MS analysis of a water sample from ISS that contained both silver(I) and colloidal silver. Potential earth-bound applications are also briefly discussed. Copyright (c) 2009 Elsevier B.V. All rights reserved.

  6. Metal quantification in water and sediment samples of billings reservoir by SR-TXRF

    International Nuclear Information System (INIS)

    Sampaio, Sergio Arnaud; Moreira, Silvana; Vives, Ana Elisa Sirito de

    2007-01-01

    Billings is the largest reservoir water of the metropolitan Sao Paulo area, with approximately 100km 2 of water. Its basin hydrographic occupies more than 500km 2 in six cities. It concentrates the largest industrial park of South America and only its margins are busy for almost a million inhabitants. The quality of its waters is, therefore, constant of concern of the whole society. In this work the Synchrotron Radiation Total Reflection X Ray Fluorescence (SR-TXRF) is applied for the identification and quantification of metals in waters and sediments of the Billings dam. A comparison of the levels of metals found with the maximum permissive limits established by the Brazilian legislation was made. The purpose of social context is to contribute for the preservation of the local springs and the rational use of its waters. For the field work they were chosen 19 collection points, included the margins and the central portion of the dam, in agreement with similar approaches the those adopted by the Company of Technology of Environmental Sanitation of Sao Paulo State (CETESB).The water and sediment samples, as well as the certified and standard samples, were analyzed at Brazilian Synchrotron Light Laboratory (LNLS), Campinas, SP, Brazil. Results indicate that the water and the sediments of the reservoir have concentrations above the legal limits. (author)

  7. Metal quantification in water and sediment samples of billings reservoir by SR-TXRF

    Energy Technology Data Exchange (ETDEWEB)

    Sampaio, Sergio Arnaud; Moreira, Silvana [Universidade Estadual de Campinas (UNICAMP), Campinas, SP (Brazil). Faculdade de Engenharia Civil, Arquitetura e Urbanismo]. E-mails: silvana@fec.unicamp.br; sergioarnaud@hotmail.com; Vives, Ana Elisa Sirito de [Universidade Metodista de Piracicaba (UNIMEP), Santa Barbara D' Oeste, SP (Brazil). Faculdade de Engenharia Civil, Arquitetura e Urbanismo]. E-mail: aesvives@unimep.br

    2007-07-01

    Billings is the largest reservoir water of the metropolitan Sao Paulo area, with approximately 100km{sup 2} of water. Its basin hydrographic occupies more than 500km{sup 2} in six cities. It concentrates the largest industrial park of South America and only its margins are busy for almost a million inhabitants. The quality of its waters is, therefore, constant of concern of the whole society. In this work the Synchrotron Radiation Total Reflection X Ray Fluorescence (SR-TXRF) is applied for the identification and quantification of metals in waters and sediments of the Billings dam. A comparison of the levels of metals found with the maximum permissive limits established by the Brazilian legislation was made. The purpose of social context is to contribute for the preservation of the local springs and the rational use of its waters. For the field work they were chosen 19 collection points, included the margins and the central portion of the dam, in agreement with similar approaches the those adopted by the Company of Technology of Environmental Sanitation of Sao Paulo State (CETESB).The water and sediment samples, as well as the certified and standard samples, were analyzed at Brazilian Synchrotron Light Laboratory (LNLS), Campinas, SP, Brazil. Results indicate that the water and the sediments of the reservoir have concentrations above the legal limits. (author)

  8. Sampling designs and methods for estimating fish-impingement losses at cooling-water intakes

    International Nuclear Information System (INIS)

    Murarka, I.P.; Bodeau, D.J.

    1977-01-01

    Several systems for estimating fish impingement at power plant cooling-water intakes are compared to determine the most statistically efficient sampling designs and methods. Compared to a simple random sampling scheme the stratified systematic random sampling scheme, the systematic random sampling scheme, and the stratified random sampling scheme yield higher efficiencies and better estimators for the parameters in two models of fish impingement as a time-series process. Mathematical results and illustrative examples of the applications of the sampling schemes to simulated and real data are given. Some sampling designs applicable to fish-impingement studies are presented in appendixes

  9. [Identification of Systemic Contaminations with Legionella Spec. in Drinking Water Plumbing Systems: Sampling Strategies and Corresponding Parameters].

    Science.gov (United States)

    Völker, S; Schreiber, C; Müller, H; Zacharias, N; Kistemann, T

    2017-05-01

    After the amendment of the Drinking Water Ordinance in 2011, the requirements for the hygienic-microbiological monitoring of drinking water installations have increased significantly. In the BMBF-funded project "Biofilm Management" (2010-2014), we examined the extent to which established sampling strategies in practice can uncover drinking water plumbing systems systemically colonized with Legionella. Moreover, we investigated additional parameters that might be suitable for detecting systemic contaminations. We subjected the drinking water plumbing systems of 8 buildings with known microbial contamination (Legionella) to an intensive hygienic-microbiological sampling with high spatial and temporal resolution. A total of 626 drinking hot water samples were analyzed with classical culture-based methods. In addition, comprehensive hygienic observations were conducted in each building and qualitative interviews with operators and users were applied. Collected tap-specific parameters were quantitatively analyzed by means of sensitivity and accuracy calculations. The systemic presence of Legionella in drinking water plumbing systems has a high spatial and temporal variability. Established sampling strategies were only partially suitable to detect long-term Legionella contaminations in practice. In particular, the sampling of hot water at the calorifier and circulation re-entrance showed little significance in terms of contamination events. To detect the systemic presence of Legionella,the parameters stagnation (qualitatively assessed) and temperature (compliance with the 5K-rule) showed better results. © Georg Thieme Verlag KG Stuttgart · New York.

  10. Data Validation Package October 2015 Groundwater and Surface Water Sampling at the Monticello, Utah, Processing Site January 2016

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Jason [U.S. Dept. of Energy, Washington, DC (United States). Office of Legacy Management; Smith, Fred [Navarro Research and Engineering, Inc., Oak Ridge, TN (United States)

    2016-01-21

    Sampling Period: October 12–14, 2015. This semiannual event includes sampling groundwater and surface water at the Monticello Mill Tailings Site. Sampling and analyses were conducted as specified in the 2004 Monticello Mill Tailings Site Operable Unit III Post-Record of Decision Monitoring Plan, Draft Final and Sampling and Analysis Plan for U.S. Department of Energy Office of Legacy Management Sites (LMS/PRO/S04351, continually updated). Samples were collected from 52 of 61 planned locations (15 of 17 former mill site wells, 17 of 18 downgradient wells, 9 of 9 downgradient permeable reactive barrier wells, 2 of 7 seeps and wetlands, and 9 of 10 surface water locations). Locations MW00-07, Seep 1, Seep 2, Seep 3, Seep 5, Seep 6, SW00-01, T01-13, and T01-19 were not sampled because of insufficient water availability. All samples were filtered as specified in the monitoring plan. Duplicate samples were collected from surface water location W3-04 and from monitoring wells 82-08, 92-09, and 92-10. Water levels were measured at all but one sampled well and an additional set of wells. The contaminants of concern (COCs) for the Monticello Mill Tailings Site are arsenic, manganese, molybdenum, nitrate + nitrite as nitrogen (nitrate + nitrite as N), selenium, uranium, and vanadium. Time-concentration graphs of the COCs for all groundwater and surface water locations are included in this report. Locations with COCs that exceeded remediation goals are listed.

  11. Aircraft-crash-protected roof design for the European SBWR

    International Nuclear Information System (INIS)

    Posta, B.A.; Kadar, I.; Rao, A.S.

    1995-01-01

    The European utility requirement document (EURD) places significant emphasis on aircraft crash protection of the reactor building - Alternative concepts were evaluated for protecting the dry-well head and the fuel pool from the effect of the spalling concrete for the General Electric Company's European simplified boiling water reactor (ESBWR) designs

  12. Studies on radon concentration in underground water samples in and around Kabini river basin

    International Nuclear Information System (INIS)

    Yashaswini, T.; Ningappa, C.; Niranjan, R.S.; Sannappa, J.

    2017-01-01

    Radon is a radioactive inert gas, a decay product of radium, causes environmental health problems like lung cancer. Radium present in the earth crest continuously releases radon into underground water. From the point view of health, the study of radon concentration level in underground water base line data is important. In the present study, radon concentration in underground water have been measured in 40 underground water samples collected in and around Kabini River of Karnataka State by using Emanometry technique. The radon concentration in the study area varies from 21.2 to 168.2Bq.l -1 with a geometrical mean value of 73.3 Bq.l -1 . The physicochemical parameters of water such as chloride, Fluoride, nitrite, sulphate, TDS are measured in the same samples in order to know about the impact of these parameters on radon concentration and their health risks to the general public. The experimental techniques and results obtained are discussed in the presentation. (author)

  13. Comparison of Water Flows in Four European Lagoon Catchments under a Set of Future Climate Scenarios

    Directory of Open Access Journals (Sweden)

    Cornelia Hesse

    2015-02-01

    Full Text Available Climate change is supposed to remarkably affect the water resources of coastal lagoons as they are highly vulnerable to changes occurring at their catchment and/or ocean or sea boundaries. Probable impacts of projected climate changes on catchment hydrology and freshwater input were assessed using the eco-hydrological model SWIM (Soil and Water Integrated Model for the drainage areas of four European lagoons: Ria de Aveiro (Portugal, Mar Menor (Spain, Tyligulskyi Liman (Ukraine and Vistula Lagoon (Poland/Russia under a set of 15 climate scenarios covering the time period until the year 2100. Climate change signals for all regions show continuously increasing trends in temperature, but various trends in precipitation. Precipitation is projected to decrease in two catchments on the Iberian Peninsula and increase in the Baltic region catchment, and does not show a clear trend in the catchment located near the Black Sea. The average projected changes in freshwater inputs reflect these changes in climate conditions, but often show variability between the scenarios, in future periods, and within the catchments. According to the individual degrees of water management influences in the four drainage basins, the climate sensitivity of river inflows is differently pronounced in each.

  14. Characteristics of Beverage Consumption Habits among a Large Sample of French Adults: Associations with Total Water and Energy Intakes

    Directory of Open Access Journals (Sweden)

    Fabien Szabo de Edelenyi

    2016-10-01

    Full Text Available Background: Adequate hydration is a key factor for correct functioning of both cognitive and physical processes. In France, public health recommendations about adequate total water intake (TWI only state that fluid intake should be sufficient, with particular attention paid to hydration for seniors, especially during heatwave periods. The objective of this study was to calculate the total amount of water coming from food and beverages and to analyse characteristics of consumption in participants from a large French national cohort. Methods: TWI, as well as contribution of food and beverages to TWI was assessed among 94,939 adult participants in the Nutrinet-Santé cohort (78% women, mean age 42.9 (SE 0.04 using three 24-h dietary records at baseline. Statistical differences in water intakes across age groups, seasons and day of the week were assessed. Results: The mean TWI was 2.3 L (Standard Error SE 4.7 for men and 2.1 L (SE 2.4 for women. A majority of the sample did comply with the European Food Safety Authority (EFSA adequate intake recommendation, especially women. Mean total energy intake (EI was 1884 kcal/day (SE 1.5 (2250 kcal/day (SE 3.6 for men and 1783 kcal/day (SE 1.5 for women. The contribution to the total EI from beverages was 8.3%. Water was the most consumed beverage, followed by hot beverages. The variety score, defined as the number of different categories of beverages consumed during the three 24-h records out of a maximum of 8, was positively correlated with TWI (r = 0.4; and with EI (r = 0.2, suggesting that beverage variety is an indicator of higher consumption of food and drinks. We found differences in beverage consumptions and water intakes according to age and seasonality. Conclusions: The present study gives an overview of the water intake characteristics in a large population of French adults. TWI was found to be globally in line with public health recommendations.

  15. Analysis of trace uranium and plutonium in environmental water sample by ICP-MS

    International Nuclear Information System (INIS)

    Liu Xuemei

    2004-12-01

    The analysis of trace Uranium and Plutonium in environmental water is very important in the environment inspect. The preparation method of water samples are introduced and several common used method are compared. The analysis process and the calibration method with ICP-MS are discussed in detail considering present conditions. (author)

  16. [Monitoring microbiological safety of small systems of water distribution. Comparison of two sampling programs in a town in central Italy].

    Science.gov (United States)

    Papini, Paolo; Faustini, Annunziata; Manganello, Rosa; Borzacchi, Giancarlo; Spera, Domenico; Perucci, Carlo A

    2005-01-01

    To determine the frequency of sampling in small water distribution systems (distribution. We carried out two sampling programs to monitor the water distribution system in a town in Central Italy between July and September 1992; the Poisson distribution assumption implied 4 water samples, the assumption of negative binomial distribution implied 21 samples. Coliform organisms were used as indicators of water safety. The network consisted of two pipe rings and two wells fed by the same water source. The number of summer customers varied considerably from 3,000 to 20,000. The mean density was 2.33 coliforms/100 ml (sd= 5.29) for 21 samples and 3 coliforms/100 ml (sd= 6) for four samples. However the hypothesis of homogeneity was rejected (p-value samples (beta= 0.24) than with 21 (beta= 0.05). For this small network, determining the samples' size according to heterogeneity hypothesis strengthens the statement that water is drinkable compared with homogeneity assumption.

  17. Protection of drinking water reservoirs in buried glacial valleys in the ice-marginal landscape for securing future demand in the European perspective (ENCORE-Project).

    Science.gov (United States)

    Smit, F. W. H.; Bregman, E. P. H.

    2012-04-01

    Quaternary glaciations have left a significant sedimentological fingerprint in the subsurface of north Europe, in the form of buried glacial valleys. These structures are important drinking water reservoirs for millions of people in the ice-marginal landscape, but are increasingly threatened by anthropogenic pollution (nitrate, sulphate and organic pollutants) and geogenic pollution (salinization). That is one of the conclusion of a recent overview study in the IML of northern Europe from the North Sea to the southern Baltic area. Adequate policy making is yet not possible for several reasons: - Large amounts of data are needed to get a good grip on the lateral continuity of the complex infill. - The BurVal Working Group (2006) has shown that a combination of high resolution seismic survey, together with transient electromagnetic (TEM) surveys can provide realistic data for 3D hydrogeological models. However, these data have not yet been retrieved on a European scale. - Available borehole data can only be used as control points in 3D hydrological models, since the infill of buried glacial valleys is often lateral too complex to make sound interpolations possible. Pollution in buried glacial valleys crosses national borders in northern Europe and therefore national geological surveys have to cooperate in a newly formed European project on protection of these structures. The ENCORE - project (Environmental Conference of the European Regions) has shown in the past that it can facilitate fruitful European cooperation, which is urgently needed due to the costs of gathering data and due to knowledge gaps between different countries. By working together in a European context, these problems can be reduced so that better policy making is possible in order to secure our future drinking water availability.

  18. A GIS model-based assessment of the environmental distribution of γ-hexachlorocyclohexane in European soils and waters

    International Nuclear Information System (INIS)

    Vizcaino, P.; Pistocchi, A.

    2010-01-01

    The MAPPE GIS based multimedia model is used to produce a quantitative description of the behaviour of γ-hexachlorocyclohexane (γ-HCH) in Europe, with emphasis on continental surface waters. The model is found to reasonably reproduce γ-HCH distributions and variations along the years in atmosphere and soil; for continental surface waters, concentrations were reasonably well predicted for year 1995, when lindane was still used in agriculture, while for 2005, assuming severe restrictions in use, yields to substantial underestimation. Much better results were yielded when same mode of release as in 1995 was considered, supporting the conjecture that for γ-HCH, emission data rather that model structure and parameterization can be responsible for wrong estimation of concentrations. Future research should be directed to improve the quality of emission data. Joint interpretation of monitoring and modelling results, highlights that lindane emissions in Europe, despite the marked decreasing trend, persist beyond the provisions of existing legislation. - An spatially-explicit multimedia modelling strategy was applied to describe the historical distribution of γ-HCH in European soils and surface waters.

  19. Pre-concentration of uranium from water samples by dispersive liquid-liquid micro-extraction

    Energy Technology Data Exchange (ETDEWEB)

    Khajeh, Mostafa; Nemch, Tabandeh Karimi [Zabol Univ. (Iran, Islamic Republic of). Dept. of Chemistry

    2014-07-01

    In this study, a simple and rapid dispersive liquid-liquid microextraction (DLLME) was developed for the determination of uranium in water samples prior to high performance liquid chromatography with diode array detection. 1-(2-pyridylazo)-2-naphthol (PAN) was used as complexing agent. The effect of various parameters on the extraction step including type and volume of extraction and dispersive solvents, pH of solution, concentration of PAN, extraction time, sample volume and ionic strength were studied and optimized. Under the optimum conditions, the limit of detection (LOD) and preconcentration factor were 0.3 μg L{sup -1} and 194, respectively. Furthermore, the relative standard deviation of the ten replicate was <2.6%. The developed procedure was then applied to the extraction and determination of uranium in the water samples.

  20. Pre-concentration of uranium from water samples by dispersive liquid-liquid micro-extraction

    International Nuclear Information System (INIS)

    Khajeh, Mostafa; Nemch, Tabandeh Karimi

    2014-01-01

    In this study, a simple and rapid dispersive liquid-liquid microextraction (DLLME) was developed for the determination of uranium in water samples prior to high performance liquid chromatography with diode array detection. 1-(2-pyridylazo)-2-naphthol (PAN) was used as complexing agent. The effect of various parameters on the extraction step including type and volume of extraction and dispersive solvents, pH of solution, concentration of PAN, extraction time, sample volume and ionic strength were studied and optimized. Under the optimum conditions, the limit of detection (LOD) and preconcentration factor were 0.3 μg L -1 and 194, respectively. Furthermore, the relative standard deviation of the ten replicate was <2.6%. The developed procedure was then applied to the extraction and determination of uranium in the water samples.

  1. Statistical analysis of fluoride levels in human urine and drinking water samples of fluorinated area of punjab (pakistan)

    International Nuclear Information System (INIS)

    Qayyum, M.; Zaman, W.U.; Rehman, R.; Ahmad, B.; Ahmad, M.; Ali, S.; Murtaza, S

    2013-01-01

    Increasing fluoride levels in drinking water of fluorinated areas of world leading to fluorosis. For bio-monitoring of fluorosis patients, fluoride levels were determined in drinking water and human urine samples of different individuals having dental fluorosis and bony deformities from fluorotic area of Punjab (Sham Ki Bhatiyan, Pakistan) and then compared with reference samples of non fluorotic area (Queens Road, Lahore, Pakistan) using ion selective electrode methodology. Fluoride levels in fluorinated area differ significantly from control group (p < 0.05). In drinking water and human urine samples, fluoride levels in fluorinated areas were: 136.192 +- 67.836 and 94.484 +- 36.572 micro molL/sup -1/ respectively, whereas in control samples, fluoride concentrations were: 19.306 +- 2.109 and 47.154 +- 22.685 micro molL/sup -1/ in water and urine samples correspondingly. Pearson's correlation data pointed out the fact that that human urine and water fluoride concentrations have a significant positive dose response relationship with the prevalence of dental and skeletal fluorosis in fluorotic areas having higher fluoride levels in drinking water. (author)

  2. Detection of toxic compounds in real water samples using a conductometric tyrosinase biosensor

    International Nuclear Information System (INIS)

    Anh, Tuan Mai; Dzyadevych, Sergei V.; Prieur, Nicolas; Duc, Chien Nguyen; Pham, T.D.; Renault, Nicole Jaffrezic; Chovelon, Jean-Marc

    2006-01-01

    A conductometric tyrosinase biosensor for the detection of some toxic compounds including diuron, atrazine, and copper ions was developed. The work of this biosensor is based on the principle of change of conductivity of the enzyme membrane when tyrosinase either interacts with 4-chlorophenol substrate or is inhibited by pollutants. The different samples tested were solutions containing diuron, atrazine, copper, lead and zinc ions, mixtures of copper/atrazine or copper/diuron and real water samples coming from a Vietnamese river. In the last case, classical techniques such as GC-MS or atomic absorption spectrometry were used in order to estimate exact concentration of these species in real water samples. Results have shown that such a biosensor could be used as an early warning system for the detection of these pollutants, as no matrix effect coming from the real sample was observed and no synergetic or antagonist effects were found for the mixture of toxic compounds. In addition, results were coherent with the content of the tyrosinase inhibitors

  3. Detection of toxic compounds in real water samples using a conductometric tyrosinase biosensor

    Energy Technology Data Exchange (ETDEWEB)

    Anh, Tuan Mai [Laboratoire d' Application de la Chimie a l' Environnement, UMR CNRS 5634, Universite Claude Bernard Lyon I, 43 Boulevard du 11 Nov. 1918, 69622 Villeurbanne Cedex (France); International Training Institute for Materials Science (ITIMS), Hanoi University of Technology, 1 Dai Co Viet, Hanoi, Vietnam (Viet Nam); Dzyadevych, Sergei V. [Laboratory of Biomolecular Electronics, Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine, 150 Zabolotnogo Str., Kiev 03143 (Ukraine); Prieur, Nicolas [Institute of Natural Products Chemistry, Vietnam National Centre for Science and Technology, Hoang Quoc Viet Str., Hanoi, Vietnam (Viet Nam); Duc, Chien Nguyen [International Training Institute for Materials Science (ITIMS), Hanoi University of Technology, 1 Dai Co Viet, Hanoi, Vietnam (Viet Nam); Pham, T.D. [International Training Institute for Materials Science (ITIMS), Hanoi University of Technology, 1 Dai Co Viet, Hanoi, Vietnam (Viet Nam); Renault, Nicole Jaffrezic [Ecole Centrale de Lyon, CEGELY, UMR CNRS 5005, 36 Avenue Guy de Collongue, 69134 Ecully Cedex (France); Chovelon, Jean-Marc [Laboratoire d' Application de la Chimie a l' Environnement, UMR CNRS 5634, Universite Claude Bernard Lyon I, 43 Boulevard du 11 Nov. 1918, 69622 Villeurbanne Cedex (France)]. E-mail: chovelon@univ-lyon1.fr

    2006-03-15

    A conductometric tyrosinase biosensor for the detection of some toxic compounds including diuron, atrazine, and copper ions was developed. The work of this biosensor is based on the principle of change of conductivity of the enzyme membrane when tyrosinase either interacts with 4-chlorophenol substrate or is inhibited by pollutants. The different samples tested were solutions containing diuron, atrazine, copper, lead and zinc ions, mixtures of copper/atrazine or copper/diuron and real water samples coming from a Vietnamese river. In the last case, classical techniques such as GC-MS or atomic absorption spectrometry were used in order to estimate exact concentration of these species in real water samples. Results have shown that such a biosensor could be used as an early warning system for the detection of these pollutants, as no matrix effect coming from the real sample was observed and no synergetic or antagonist effects were found for the mixture of toxic compounds. In addition, results were coherent with the content of the tyrosinase inhibitors.

  4. Determination of lead at nanogram level in water samples by ...

    African Journals Online (AJOL)

    A novel method of chemistry applicable to the determination of trace lead in water samples based on the resonance light scattering (RLS) technique has been developed. In dilute phosphoric acid medium, in the presence of a large excess of I-, Pb(II) can form [PbI4]2-, which further reacts with tetrabutyl ammonium bromide ...

  5. 129I, 60Co, and 106Ru measurements on water samples from the Hanford project environs

    International Nuclear Information System (INIS)

    Brauer, F.P.; Rieck, H.G. Jr.

    1973-01-01

    Groundwater flow and contamination patterns beneath the Hanford project reservation have been studied since the early days of the project. The measurement of radioactive materials at concentrations much below those required for radiation protection are useful for tracing groundwater movement and detection of potential contamination problems before they are apt to occur. Groundwater samples from a number of wells on or near the Hanford reservation have been analyzed for 129 I by neutron activation analysis and for gamma radioactivity by low-level coincidence gamma-ray spectrometry. The major radionuclides in addition to natural radioactivity detected in the underground waters by gamma-ray spectrometry were 106 Ru and 60 Co. Local river and rain water samples were also analyzed for 129 I and long-lived radionuclides. Special sample collection methods were developed to prevent contamination of the water samples during collection. Anions travel farther than cations in underground water systems since soils are primarily cation exchangers and retain the cations. Anion exchange techniques were used in the field and the laboratory to recover the desired radionuclides. Sample sizes ranged up to several thousand liters. This paper discusses the sample collection methods,analysis methods, and results obtained. The methods used were found to provide high sensitivity for groundwater studies. (auth)

  6. Concentration and characteristics of depleted uranium in biological and water samples collected in Bosnia and Herzegovina

    International Nuclear Information System (INIS)

    Jia Guogang; Belli, Maria; Sansone, Umberto; Rosamilia, Silvia; Gaudino, Stefania

    2006-01-01

    During Balkan conflicts in 1994-1995, depleted uranium (DU) ordnance was employed and was left in the battlefield. Health concern is related to the risk arising from contamination of the environment with DU penetrators and dust. In order to evaluate the impact of DU on the environment and population in Bosnia and Herzegovina, radiological survey of DU in biological and water samples were carried out over the period 12-24 October 2002. The uranium isotopic concentrations in biological samples collected in Bosnia and Herzegovina, mainly lichens, mosses and barks, were found to be in the range of 0.27-35.7 Bq kg -1 for 238 U, 0.24-16.8 Bq kg -1 for 234 U, and 0.02-1.11 Bq kg -1 for 235 U, showing uranium levels to be higher than in the samples collected at the control site. Moreover, the 236 U in some of the samples was detectable. The isotopic ratios of 234 U/ 238 U showed DU to be detectable in many biological samples at most sites examined, but in very low levels. The presence of DU in the biological samples was as a result of DU contamination in air. The uranium concentrations in water samples collected in Bosnia and Herzegovina were found to be in the range of 0.27-16.2 mBq l -1 for 238 U, 0.41-15.6 mBq l -1 for 234 U and 0.012-0.695 mBq l -1 for 235 U, and two water samples were observed to be DU positive; these values are much lower than those in mineral water found in central Italy and below the WHO guideline for public drinking water. From radiotoxicological point of view, at this moment there is no significant radiological risk related to these investigated sites in terms of possible DU contamination of water and/or plants

  7. Water reactor fuel research at the Joint Research Centre of the Commission of the European Union

    Energy Technology Data Exchange (ETDEWEB)

    Markgraf, J [HFR Unit, Inst. for Advanced Materials, Petten (Netherlands)

    1997-12-01

    The JRC programmes 1995-1998 are in progress within 8 JRC Institutes located within different research centres situated in five member states of the European Union. Except for the area of reactor safety and waste management, there are no JRC research programmes related to water reactor fuel directly. However, the JRC is providing support on basis of contracts and cooperations to bilateral and international R and D programmes through access to its large test facilities like the High Flux Reactor at the JRC Petten and the hot cell facilities of the Transuranium Institute at the JRC Karlsruhe. Access is available to customers from all over the world. 3 tabs.

  8. Cost-effective sampling of ground water monitoring wells. Revision 1

    International Nuclear Information System (INIS)

    Ridley, M.; Johnson, V.

    1995-11-01

    CS is a systematic methodology for estimating the lowest-frequency sampling schedule for a given groundwater monitoring location which will still provide needed information for regulatory and remedial decision-making. Increases in frequency dictated by remedial actions are left to the judgement of personnel reviewing the recommendations. To become more applicable throughout the life cycle of a ground water cleanup project or for compliance monitoring, several improvements are envisioned, including: chemical signature analysis to identify minimum suites of contaminants for a well, a simple flow and transport model so that sampling of downgradient wells are increased before movement of contamination, and a sampling cost estimation capability. By blending qualitative and quantitative approaches, we hope to create a defensible system while retaining interpretation ease and relevance to decision making

  9. Detection of viable Helicobacter pylori inside free-living amoebae in wastewater and drinking water samples from Eastern Spain.

    Science.gov (United States)

    Moreno-Mesonero, Laura; Moreno, Yolanda; Alonso, José Luis; Ferrús, M Antonia

    2017-10-01

    Helicobacter pylori is one of the most concerning emerging waterborne pathogens. It has been suggested that it could survive in water inside free-living amoebae (FLA), but nobody has studied this relationship in the environment yet. Thus, we aimed to detect viable H. pylori cells from inside FLA in water samples. Sixty-nine wastewater and 31 drinking water samples were collected. FLA were purified and identified by PCR and sequencing. For exclusively detecting H. pylori inside FLA, samples were exposed to sodium hypochlorite and assayed by specific PMA-qPCR, DVC-FISH and culture. FLA were detected in 38.7% of drinking water and 79.7% of wastewater samples, even after disinfection. In wastewater, Acanthamoeba spp. and members of the family Vahlkampfiidae were identified. In drinking water, Acanthamoeba spp. and Echinamoeba and/or Vermamoeba were present. In 39 (58.2%) FLA-positive samples, H. pylori was detected by PMA-qPCR. After DVC-FISH, 21 (31.3%) samples harboured viable H. pylori internalized cells. H. pylori was cultured from 10 wastewater samples. To our knowledge, this is the first report that demonstrates that H. pylori can survive inside FLA in drinking water and wastewater, strongly supporting the hypothesis that FLA could play an important role in the transmission of H. pylori to humans. © 2017 Society for Applied Microbiology and John Wiley & Sons Ltd.

  10. A large replication study and meta-analysis in European samples provides further support for association of AHI1 markers with schizophrenia

    DEFF Research Database (Denmark)

    Ingason, Andrés; Giegling, Ina; Cichon, Sven

    2010-01-01

    The Abelson helper integration site 1 (AHI1) gene locus on chromosome 6q23 is among a group of candidate loci for schizophrenia susceptibility that were initially identified by linkage followed by linkage disequilibrium mapping, and subsequent replication of the association in an independent sample....... Here, we present results of a replication study of AHI1 locus markers, previously implicated in schizophrenia, in a large European sample (in total 3907 affected and 7429 controls). Furthermore, we perform a meta-analysis of the implicated markers in 4496 affected and 18,920 controls. Both...... as the neighbouring phosphodiesterase 7B (PDE7B)-may be considered candidates for involvement in the genetic aetiology of schizophrenia....

  11. Analysis of ground water and soil samples from severely arsenic affected blocks of Murshidabad district

    Directory of Open Access Journals (Sweden)

    Manali Biswas

    2017-10-01

    Full Text Available Contamination of groundwater and soil by arsenic is a serious threat to existence of mankind on the globe. Arsenic contaminates soil and groundwater by natural biogeochemical cycles. However, due to anthropogenic activities like indiscriminant use of arsenic in disinfectants, weedicides, medicines and fertilizers, arsenic toxicity is a severe environmental issue, both at national and global level. U.S. Environmental Protection Agency and World Health Organization prescribed the permissible limit of arsenic in drinking water to be 10 µg/l. Exposure to arsenic at higher levels over a considerable period of time leads to skin lesions and cancer, disorders of cardiovascular, respiratory, gastrointestinal, hepatic and renal systems. Murshidabad is one of the severely arsenic affected districts of West Bengal. We have analyzed soil and groundwater samples from some of the highly arsenic affected blocks of Murshidabad district. Both the soil and groundwater samples have an alkaline pH, a characteristic of the presence of arsenic in the tested samples. Unfortunately, the socio-economic conditions of these villages force the residents to use groundwater as the source of drinking water. Presence of considerably high amount of total dissolved solids in water samples make them further unfit for consumption. High amount of phosphate and iron present in some of the water samples takes a toll on the detoxification and excretory system of the body, if those water samples are consumed on a regular manner. Contamination of soil by the aforesaid contaminants results in biomagnification of these pollutants in the food chain. We could also isolate certain potentially arsenic resistant bacteria from the contaminated soil and water samples. At the next level we have surveyed an arsenic affected village to analyze the clinical manifestation of arsenic poisoning. In this village subjects developed rampant skin lesions throughout the body due to exposure to arsenic

  12. Tritium Activity Measurement of Water Samples Using Liquid Scintillation Counter and Electrolytical Enrichment

    International Nuclear Information System (INIS)

    Baresic, J.; Krajcar Bronic, I.; Horvatincic, N.; Obelic, B.; Sironic, A.; Kozar-Logar J.

    2011-01-01

    Tritium (3H) activity of natural waters (precipitation, groundwater, surface waters) has recently become too low to be directly measured by low-level liquid scintillation (LSC) techniques. It is therefore necessary to perform electrolytical enrichment of tritium in such waters prior to LSC measurements. Electrolytical enrichment procedure has been implemented at the Rudjer Boskovic Institute (RBI) Tritium Laboratory in 2008, and since then 19 electrolyses have been completed. The mean enrichment factor E (a ratio between the final and initial 3H activities) after stabilisation of the system is E R BI = 22.5 @ 0.5, and the mean enrichment parameter (which describes the process of water mass reduction during electrolysis) is P R BI 0.949 @ 0.003. These values are comparable with those obtained at the Jo@ef Stefan Institute (JSI) Laboratory for liquid scintillation counting, at the electrolysis equipment of the same producer (AGH University of Science and Technology, Krakow, Poland) after 66 electrolyses carried out under identical conditions since 2007: E J SI = 18.9 @ 1.5, and P J SI = 0.896 @ 0.021. Both RBI and JSI laboratories have Ultra-low-level LSC Quantulus 1220 (Wallac, PerkinElmer) for measurement of 3H activity. A set of water samples having 3H activities in the range from 0 TU (''dead-water'' samples) to 18 000 TU (1 TU 0.118 Bq/L) were measured at both laboratories. Samples having 3H activity <200 TU were electrolytically enriched, while the others were measured directly in LSC. A very good agreement was obtained (correlation coefficient 0.991). Both laboratories participated in the IAEA TRIC2008 international intercomparison exercise. The analyses of reported 3H activity results in terms of z and u parameters showed that all results in both laboratories were acceptable. (author)

  13. Discarded fish in European waters: general patterns and contrasts

    DEFF Research Database (Denmark)

    Uhlmann, Sebastian S.; Helmond, Aloysius T. M. van; Stefansdottir, Elisabet Kemp

    2014-01-01

    To reduce the practice of discarding commercially fished organisms, several measures such as a discard ban and extra allowances on top of landings quotas (“catch quota”) have been proposed by the European Commission. However, for their development and successful implementation, an understanding...

  14. Natural Water Retention Measures (NWRM): from Design to Implementation through European Projects; Las Medidas Naturales de Retencion de Agua: del diseno a la implementacion a traves de proyectos europeos

    Energy Technology Data Exchange (ETDEWEB)

    Magdaleno Mas, F.; Dalacamara Andres, G.

    2015-07-01

    The Centre for Applied Technique Studies (CETA) of CEDEX has been working over the last few years in different European projects related with the design and development of natural water retention measures (NWRM). These are a number of measures, boosted by the Water Unit of the Environment Directorate-General of the European Commission. with close links to green infrastructures, which try to integrate, from a multifunctional approach, different legal and technical requirements aimed at a better adaptation to extreme hydro meteorological events, environmental protection and conservation, and maintenance of ecosystem services. This paper reviews the underpinning foundations of the concept and the mechanisms for designing and implementing NWRM. It also shows the way they can be applied, by presenting different initiatives developed by CETA since 2008 in Navarra (Arga-Aragon rivers system). For fulfilling those works, CETA has collaborated with environmental and hydraulic authorities of Navarra. It has also actively cooperated with research centres, such as the Institute IMDEA Water. specifically in a European project devoted to the diffusion, assessment, and presentation of NWRM within the context of the EU River Basin Districts. (Author)

  15. Carbon, land, and water footprint accounts for the European Union: consumption, production, and displacements through international trade.

    Science.gov (United States)

    Steen-Olsen, Kjartan; Weinzettel, Jan; Cranston, Gemma; Ercin, A Ertug; Hertwich, Edgar G

    2012-10-16

    A nation's consumption of goods and services causes various environmental pressures all over the world due to international trade. We use a multiregional input-output model to assess three kinds of environmental footprints for the member states of the European Union. Footprints are indicators that take the consumer responsibility approach to account for the total direct and indirect effects of a product or consumption activity. We quantify the total environmental pressures (greenhouse gas emissions: carbon footprint; appropriation of biologically productive land and water area: land footprint; and freshwater consumption: water footprint) caused by consumption in the EU. We find that the consumption activities by an average EU citizen in 2004 led to 13.3 tCO(2)e of induced greenhouse gas emissions, appropriation of 2.53 gha (hectares of land with global-average biological productivity), and consumption of 179 m(3) of blue water (ground and surface water). By comparison, the global averages were 5.7 tCO(2)e, 1.23 gha, and 163 m(3) blue water, respectively. Overall, the EU displaced all three types of environmental pressures to the rest of the world, through imports of products with embodied pressures. Looking at intra-EU displacements only, the UK was the most important displacer overall, while the largest net exporters of embodied environmental pressures were Poland (greenhouse gases), France (land), and Spain (freshwater).

  16. Spraguea lophii (Microsporidia) parasitizing blackbellied angler (Lophius budegassa) and angler (L. piscatorius) in European Atlantic waters

    Science.gov (United States)

    Landa, Jorge; Cañás, Lucía

    2017-12-01

    Blackbellied angler (Lophius budegassa) and angler (L. piscatorius) are two important commercial species in the Bay of Biscay and the European fisheries infected by the microsporidian parasite Spraguea lophii. Samplings of both anglerfish were performed from a nine year time-series (2006-2014) from commercial fleet and bottom research surveys operating in southern Bay of Biscay and Galician waters (ICES Div. VIIIc and IXa2), Celtic Sea (Div. VIIh), south-western Ireland (Div. VIIj and VIIk), western Ireland and Porcupine Bank (Div. VIIb and VIIc). Length and sex of fish and presence or absence of the parasite were recorded. The prevalence by Spraguea was used to analyse the infection level. The role of each variable (fish length, fish sex, geographical area and year) and the interactions among them on the Spraguea prevalence were analyzed by using a binomial GLM. Area and fish length had a more relevant effect on the infestation of both anglerfish, while the impact of the year and fish sex was less evident. The Spraguea prevalence by area ranged between 11% and 52% in L. budegassa and between 39% and 66% in L. piscatorius. This is the first study in which the prevalence of this parasite in L. budegassa is analyzed in several areas and inter-annually compared. A non-linear relationship with a sharp increment of the prevalence with fish length was obtained in both anglerfish. The results were compared with those from the scarce previous studies and discussed.

  17. Analytical results for 544 water samples collected in the Attean Quartz Monzonite in the vicinity of Jackman, Maine

    Science.gov (United States)

    Ficklin, W.H.; Nowlan, G.A.; Preston, D.J.

    1983-01-01

    Water samples were collected in the vicinity of Jackman, Maine as a part of the study of the relationship of dissolved constituents in water to the sediments subjacent to the water. Each sample was analyzed for specific conductance, alkalinity, acidity, pH, fluoride, chloride, sulfate, phosphate, nitrate, sodium, potassium, calcium, magnesium, and silica. Trace elements determined were copper, zinc, molybdenum, lead, iron, manganese, arsenic, cobalt, nickel, and strontium. The longitude and latitude of each sample location and a sample site map are included in the report as well as a table of the analytical results.

  18. Use of Cdse/ZnS quantum dots for sensitive detection and quantification of paraquat in water samples

    Energy Technology Data Exchange (ETDEWEB)

    Durán, Gema M. [Department of Analytical Chemistry and Food Technology, University of Castilla – La Mancha, Avenida Camilo José Cela, 10, 13004 Ciudad Real (Spain); IRICA (Regional Institute of Applied Scientific Research), Avenida Camilo José Cela, s/n., 13071 Ciudad Real (Spain); Contento, Ana M. [Department of Analytical Chemistry and Food Technology, University of Castilla – La Mancha, Avenida Camilo José Cela, 10, 13004 Ciudad Real (Spain); Ríos, Ángel, E-mail: Angel.Rios@uclm.es [Department of Analytical Chemistry and Food Technology, University of Castilla – La Mancha, Avenida Camilo José Cela, 10, 13004 Ciudad Real (Spain)

    2013-11-01

    Graphical abstract: -- Highlights: •Analytical use of CdSe/ZnS quantum dots. •Methodology for water solubilization of CdSe/ZnS QDs. •Sensitive and selective reaction with paraquat herbicide. •Application to water samples. -- Abstract: Based on the highly sensitive fluorescence change of water-soluble CdSe/ZnS core-shell quantum dots (QD) by paraquat herbicide, a simple, rapid and reproducible methodology was developed to selectively determine paraquat (PQ) in water samples. The methodology enabled the use of simple pretreatment procedure based on the simple water solubilization of CdSe/ZnS QDs with hydrophilic heterobifunctional thiol ligands, such as 3-mercaptopropionic acid (3-MPA), using microwave irradiation. The resulting water-soluble QDs exhibit a strong fluorescence emission at 596 nm with a high and reproducible photostability. The proposed analytical method thus satisfies the need for a simple, sensible and rapid methodology to determine residues of paraquat in water samples, as required by the increasingly strict regulations for health protection introduced in recent years. The sensitivity of the method, expressed as detection limits, was as low as 3.0 ng L{sup −1}. The lineal range was between 10–5 × 10{sup 3} ng L{sup −1}. RSD values in the range of 71–102% were obtained. The analytical applicability of proposed method was demonstrated by analyzing water samples from different procedence.

  19. Use of Cdse/ZnS quantum dots for sensitive detection and quantification of paraquat in water samples

    International Nuclear Information System (INIS)

    Durán, Gema M.; Contento, Ana M.; Ríos, Ángel

    2013-01-01

    Graphical abstract: -- Highlights: •Analytical use of CdSe/ZnS quantum dots. •Methodology for water solubilization of CdSe/ZnS QDs. •Sensitive and selective reaction with paraquat herbicide. •Application to water samples. -- Abstract: Based on the highly sensitive fluorescence change of water-soluble CdSe/ZnS core-shell quantum dots (QD) by paraquat herbicide, a simple, rapid and reproducible methodology was developed to selectively determine paraquat (PQ) in water samples. The methodology enabled the use of simple pretreatment procedure based on the simple water solubilization of CdSe/ZnS QDs with hydrophilic heterobifunctional thiol ligands, such as 3-mercaptopropionic acid (3-MPA), using microwave irradiation. The resulting water-soluble QDs exhibit a strong fluorescence emission at 596 nm with a high and reproducible photostability. The proposed analytical method thus satisfies the need for a simple, sensible and rapid methodology to determine residues of paraquat in water samples, as required by the increasingly strict regulations for health protection introduced in recent years. The sensitivity of the method, expressed as detection limits, was as low as 3.0 ng L −1 . The lineal range was between 10–5 × 10 3 ng L −1 . RSD values in the range of 71–102% were obtained. The analytical applicability of proposed method was demonstrated by analyzing water samples from different procedence

  20. Estimation of radon concentration in soil and groundwater samples of Northern Rajasthan, India

    International Nuclear Information System (INIS)

    Mittal, Sudhir; Asha Rani; Mehra, Rohit

    2015-01-01

    In the present investigation, analysis of radon concentration in 20 water and soil samples collected from different locations of Bikaner and Jhunjhunu districts of Rajasthan, India has been carried out by using RAD7 an electronic Radon detector. The water samples are taken from hand pumps and tube wells having depths ranging from 50 to 600 feet. All the soil gas measurements have been carried out at 100 cm depth. The measured radon concentration in water samples lies in the range from 0.50 to 22 Bq l -1 with the mean value of 4.42 Bq l -1 . Only in one water sample radon concentration is found to be higher than the safe limit of 11 Bq l -1 recommended US Environmental Protection Agency (USEPA, 1991). The measured value of radon concentration in all ground water samples is within the safe limit from 4 to 40 Bq l -1 recommended by United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR, 2008). The total annual effective dose estimated due to radon concentration in water ranges from 1.37 to 60 μSV y -1 with the mean value of 12.08 μSV y -1 . The total annual effective dose from all locations of our studied area is found to be well within the safe limit 0.1 mSv y -1 recommended by World Health Organization (WHO, 2004) and European Council (ED, 1998). Radon measurement in soil samples varies from 941 to 10050 Bq m -3 with the mean value of 4561 Bq m -3 , The radon concentration observed from the soil samples from our study area lies within the range reported by other investigators. Moreover a positive correlation of radon concentration in water with soil samples has been observed. It was observed that the soil and water of Bikaner and Jhunjhunu districts are suitable for drinking and construction purpose without posing any health hazard. (author)

  1. Water Consumption in European Children: Associations with Intake of Fruit Juices, Soft Drinks and Related Parenting Practices

    Directory of Open Access Journals (Sweden)

    Krystallia Mantziki

    2017-05-01

    Full Text Available Background: High intake of fruit juices and soft drinks contributes to excessive weight gain and obesity in children. Furthermore, parenting practices play an important role in the development of children’s dietary habits. The way parents play this role in the development of their children’s choices of beverages is still unclear. Objectives: To study the associations: (1 of both fruit juices and soft drinks consumption with water consumption of children and (2 The associations between parenting practices towards fruit juices and soft drinks and water consumption of children. Design: Cross-sectional data from 6 to 8 year old children from seven European communities (n = 1187 were collected. Associations among fruit juices, soft drinks, the respective parenting practices and the child’s water consumption were assessed by parental questionnaires. Results: The consumption of water was inversely associated with that of soft drinks but not with the consumption of fruit juices. The child’s water intake was favorably influenced when stricter parenting practices towards soft drinks were adopted (e.g., less parental allowance, low home availability and high parental self-efficacy in managing intake. There was less influence observed of parenting practices towards fruit juices. Fruit juices were consumed more often than soft drinks. Conclusions: Low consumption of soft drinks—and not of fruit juices—was associated with high water consumption in children in the current study. Moreover, parenting practices towards both fruit juices and soft drinks were associated with the water intake of the children, irrespective of their socio-economic status.

  2. The origin of water in the primitive Moon as revealed by the lunar highlands samples

    Science.gov (United States)

    Barnes, Jessica J.; Tartèse, Romain; Anand, Mahesh; McCubbin, Francis M.; Franchi, Ian A.; Starkey, Natalie A.; Russell, Sara S.

    2014-03-01

    The recent discoveries of hydrogen (H) bearing species on the lunar surface and in samples derived from the lunar interior have necessitated a paradigm shift in our understanding of the water inventory of the Moon, which was previously considered to be a ‘bone-dry’ planetary body. Most sample-based studies have focused on assessing the water contents of the younger mare basalts and pyroclastic glasses, which are partial-melting products of the lunar mantle. In contrast, little attention has been paid to the inventory and source(s) of water in the lunar highlands rocks which are some of the oldest and most pristine materials available for laboratory investigations, and that have the potential to reveal the original history of water in the Earth-Moon system. Here, we report in-situ measurements of hydroxyl (OH) content and H isotopic composition of the mineral apatite from four lunar highlands samples (two norites, a troctolite, and a granite clast) collected during the Apollo missions. Apart from troctolite in which the measured OH contents in apatite are close to our analytical detection limit and its H isotopic composition appears to be severely compromised by secondary processes, we have measured up to ˜2200 ppm OH in the granite clast with a weighted average δD of ˜ -105±130‰, and up to ˜3400 ppm OH in the two norites (77215 and 78235) with weighted average δD values of -281±49‰ and -27±98‰, respectively. The apatites in the granite clast and the norites are characterised by higher OH contents than have been reported so far for highlands samples, and have H isotopic compositions similar to those of terrestrial materials and some carbonaceous chondrites, providing one of the strongest pieces of evidence yet for a common origin for water in the Earth-Moon system. In addition, the presence of water, of terrestrial affinity, in some samples of the earliest-formed lunar crust suggests that either primordial terrestrial water survived the aftermath

  3. Development and evaluation of a gas chromatographic method for the determination of triazine herbicides in natural water samples

    Science.gov (United States)

    Steinheimer, T.R.; Brooks, M.G.

    1984-01-01

    A multi-residue method is described for the determination of triazine herbicides in natural water samples. The technique uses solvent extraction followed by gas chromatographic separation and detection employing nitrogen-selective devices. Seven compounds can be determined simultaneously at a nominal detection limit of 0.1 ??g/L in a 1-litre sample. Three different natural water samples were used for error analysis via evaluation of recovery efficiencies and estimation of overall method precision. As an alternative to liquid-liquid partition (solvent extraction) for removal of compounds of interest from water, solid-phase extraction (SPE) techniques employing chromatographic grade silicas with chemically modified surfaces have been examined. SPE is found to provide rapid and efficient concentration with quantitative recovery of some triazine herbicides from natural water samples. Concentration factors of 500 to 1000 times are obtained readily by the SPE technique.A multi-residue method is described for the determination of triazine herbicides in natural water samples. The technique uses solvent extraction followed by gas chromatographic separation and detection employing nitrogen-selective devices. Seven compounds can be determined simultaneously at a nominal detection limit of 0. 1 mu g/L in a 1-litre sample. As an alternative to liquid-liquid partition (solvent extraction) for removal of compounds of interest from water, solid-phase extraction (SPE) techniques employing chromatographic grade silicas with chemically modified surfaces have been examined. SPE is found to provide rapid and efficient concentration with quantitative recovery of some triazine herbicides from natural water samples. Concentration factors of 500 to 1000 times are obtained readily by the SPE technique.

  4. Enrichment and determination of small amounts of 90Sr/90Y in water samples

    International Nuclear Information System (INIS)

    Mundschenk, H.

    1979-01-01

    Small amounts of 90 Sr/ 90 Y can be concentrated from large volumes of surface water (100 l) by precipitation of the phosphates, using bentonite as adsorber matrix. In the case of samples containing no or nearly no suspended matter (tap water, ground water, sea water), the daughter 90 Y can be extracted directly by using filter beds impregnated with HDEHP. The applicability of both techniques is demonstrated under realistic conditions. (orig.) 891 HP/orig. 892 MKO [de

  5. Beverage and water intake of healthy adults in some European countries.

    Science.gov (United States)

    Nissensohn, Mariela; Castro-Quezada, Itandehui; Serra-Majem, Lluis

    2013-11-01

    Nutritional surveys frequently collect some data of consumption of beverages; however, information from different sources and different methodologies raises issues of comparability. The main objective of this review was to examine the available techniques used for assessing beverage intake in European epidemiological studies and to describe the most frequent method applied to assess it. Information of beverage intake available from European surveys and nutritional epidemiological investigations was obtained from gray literature. Twelve articles were included and relevant data were extracted. The studies were carried out on healthy adults by different types of assessments. The most frequent tool used was a 7-d dietary record. Only Germany used a specific beverage assessment tool (Beverage Dietary History). From the limited data available and the diversity of the methodology used, the results show that consumption of beverages is different between countries. Current epidemiological studies in Europe focusing on beverage intake are scarce. Further research is needed to clarify the amount of beverage intake in European population.

  6. Using Lagrangian sampling to study water quality during downstream transport in the San Luis Drain, California, USA

    Science.gov (United States)

    Volkmar, E.C.; Dahlgren, R.A.; Stringfellow, W.T.; Henson, S.S.; Borglin, S.E.; Kendall, C.; Van Nieuwenhuyse, E. E.

    2011-01-01

    To investigate the mechanism for diel (24h) changes commonly observed at fixed sampling locations and how these diel changes relate to downstream transport in hypereutrophic surface waters, we studied a parcel of agricultural drainage water as it traveled for 84h in a concrete-lined channel having no additional water inputs or outputs. Algal fluorescence, dissolved oxygen, temperature, pH, conductivity, and turbidity were measured every 30min. Grab samples were collected every 2h for water quality analyses, including nutrients, suspended sediment, and chlorophyll/pheophytin. Strong diel patterns were observed for dissolved oxygen, pH, and temperature within the parcel of water. In contrast, algal pigments and nitrate did not exhibit diel patterns within the parcel of water, but did exhibit strong diel patterns for samples collected at a fixed sampling location. The diel patterns observed at fixed sampling locations for these constituents can be attributed to algal growth during the day and downstream transport (washout) of algae at night. Algal pigments showed a rapid daytime increase during the first 48h followed by a general decrease for the remainder of the study, possibly due to sedimentation and photobleaching. Algal growth (primarily diatoms) was apparent each day during the study, as measured by increasing dissolved oxygen concentrations, despite low phosphate concentrations (<0.01mgL-1). ?? 2011 Elsevier B.V.

  7. Sampling and chemical analysis in environmental samples around Nuclear Power Plants and some environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yong Woo; Han, Man Jung; Cho, Seong Won; Cho, Hong Jun; Oh, Hyeon Kyun; Lee, Jeong Min; Chang, Jae Sook [KORTIC, Taejon (Korea, Republic of)

    2002-12-15

    Twelve kinds of environmental samples such as soil, seawater, underground water, etc. around Nuclear Power Plants(NPPs) were collected. Tritium chemical analysis was tried for the samples of rain water, pine-needle, air, seawater, underground water, chinese cabbage, a grain of rice and milk sampled around NPPs, and surface seawater and rain water sampled over the country. Strontium in the soil that sere sampled at 60 point of district in Korea were analyzed. Tritium were sampled at 60 point of district in Korea were analyzed. Tritium were analyzed in 21 samples of surface seawater around the Korea peninsular that were supplied from KFRDI(National Fisheries Research and Development Institute). Sampling and chemical analysis environmental samples around Kori, Woolsung, Youngkwang, Wooljin Npps and Taeduk science town for tritium and strontium analysis was managed according to plans. Succeed to KINS after all samples were tried.

  8. Determination of radon and radium concentrations in drinking water samples around the city of Kutahya

    International Nuclear Information System (INIS)

    Sahin, L.; Cetinkaya, H.; Murat Sac, M.; Ichedef, M.

    2013-01-01

    The concentration of radium and radon has been determined in drinking water samples collected from various locations of Kutahya city, Turkey. The water samples are taken from public water sources and tap water, with the collector chamber method used to measure the radon and radium concentration. The radon concentration ranges between 0.1 and 48.6±1.7 Bq l -1 , while the radium concentration varies from a minimum detectable activity of -1 in Kutahya city. In addition to the radon and radium levels, parameters such as pH, conductivity and temperature of the water, humidity, pressure, elevation and the coordinates of the sampling points have also been measured and recorded. The annual effective dose from radon and radium due to typical water usage has been calculated. The resulting contribution to the annual effective dose due to radon ingestion varies between 0.3 and 124.2 μSv y -1 ; the contribution to the annual effective dose due to radium ingestion varies between 0 and 143.3 μSv y -1 ; the dose contribution to the stomach due to radon ingestion varies between 0.03 and 14.9 μSv y -1 . The dose contribution due to radon inhalation ranges between 0.3 and 122.5 μSv y -1 , assuming a typical transfer of radon in water to the air. For the overwhelming majority of the Kutahya population, it is determined that the average radiation exposure from drinking water is less than 73.6μmSv y -1 . (authors)

  9. Autonomous water sampling for long-term monitoring of trace metals in remote environments.

    Science.gov (United States)

    Kim, Hyojin; Bishop, James K B; Wood, Todd J; Fung, Inez Y

    2012-10-16

    A remotely controlled autonomous method for long-term high-frequency sampling of environmental waters in remote locations is described. The method which preserves sample integrity of dissolved trace metals and major ions for month-long periods employs a gravitational filtration system (GFS) that separates dissolved and particulate phases as samples are collected. The key elements of GFS are (1) a modified "air-outlet" filter holder to maximize filtration rate and thus minimize filtration artifacts; and (2) the direct delivery of filtrate to dedicated bottle sets for specific analytes. Depth and screen filter types were evaluated with depth filters showing best performance. GFS performance is validated using ground, stream, and estuary waters. Over 30 days of storage, samples with GFS treatment had average recoveries of 95 ± 19% and 105 ± 7% of Fe and Mn, respectively; without GFS treatment, average recoveries were only 16% and 18%. Dissolved major cations K, Mg, and Na were stable independent of collection methodology, whereas Ca in some groundwater samples decreased up to 42% without GFS due to CaCO(3) precipitation. In-field performance of GFS equipped autosamplers is demonstrated using ground and streamwater samples collected at the Angelo Coast Range Reserve, California from October 3 to November 4 2011.

  10. European Communities (Drinking water) Regulations, 2000

    International Nuclear Information System (INIS)

    2000-12-01

    These Regulations were adopted as Statutory Instrument No. 439 of 2000 on 18 December 2000 and come in to operation on 1 January 2004. The regulations give effect to provisions of EU Council Directive 98/83/EC on the quality of water intended for human consumption.. They prescribe quality standards to be applied in relation to certain supplies of drinking water. S.I. 439 of 2000 stipulates that the radiation dose arising from one year's consumption of drinking water should not exceed 0.1 mSv. It further stipulates that the dose calculation should include contributions from all natural and artificial radionuclides with the exception of tritium, potassium-40, radon and radon decay products

  11. Removal of arsenic from ground water samples collected from West Bengal, India

    International Nuclear Information System (INIS)

    Ajith, Nicy; Swain, K.K.; Dalvi, Aditi A.; Verma, R.

    2015-01-01

    Arsenic contamination in ground water is one of the major concerns in many parts of the world including Bangladesh and India. Considering the high toxicity of arsenic, World Health Organization (WHO) has set a provisional guideline value of 10 μg L -1 for arsenic in drinking water. Several methods have been adopted for the removal of arsenic from drinking water. Most of the methods fail to remove As(III), the most toxic form of arsenic. An extra oxidative treatment step is essential for effective removal of total arsenic. Manganese dioxide (MnO 2 ) oxidizes As(III) to As(V). Removal of arsenic from water using manganese dioxide has been reported. During this work, removal of arsenic from ground water samples collected from arsenic contaminated area of West Bengal, India were carried out using MnO 2

  12. Results of environmental radioactivity measurements in the member states of the European Community for air, deposition, water, milk, 1975-1976

    International Nuclear Information System (INIS)

    1978-01-01

    The present document is the sixteenth report published by the Health and Safety Directorate of the Commission of the European Communities concerning ambient radioactivity. It was drawn up using the data collected by the stations in charge of the surveillance of environmental radioactivity in the Member States. The results are extracts from the data sent to the Commission in application of Article 36 of the Treaty of Rome instituting the European Atomic Energy Community. This is the second document which includes data from the enlarged community-viz. Belgium, the Federal Republic of Germany, France, Italy, Luxembourg, the Netherlands, plus Denmark, Ireland and the United Kingdom, who joined the Community on 1 January 1973. The results presented in this report deal with radioactive contamination of the air, precipitaton and fallout, surface water and milk during 1975 and 1976

  13. Trends in analytical methodologies for the determination of alkylphenols and bisphenol A in water samples.

    Science.gov (United States)

    Salgueiro-González, N; Muniategui-Lorenzo, S; López-Mahía, P; Prada-Rodríguez, D

    2017-04-15

    In the last decade, the impact of alkylphenols and bisphenol A in the aquatic environment has been widely evaluated because of their high use in industrial and household applications as well as their toxicological effects. These compounds are well-known endocrine disrupting compounds (EDCs) which can affect the hormonal system of humans and wildlife, even at low concentrations. Due to the fact that these pollutants enter into the environment through waters, and it is the most affected compartment, analytical methods which allow the determination of these compounds in aqueous samples at low levels are mandatory. In this review, an overview of the most significant advances in the analytical methodologies for the determination of alkylphenols and bisphenol A in waters is considered (from 2002 to the present). Sample handling and instrumental detection strategies are critically discussed, including analytical parameters related to quality assurance and quality control (QA/QC). Special attention is paid to miniaturized sample preparation methodologies and approaches proposed to reduce time- and reagents consumption according to Green Chemistry principles, which have increased in the last five years. Finally, relevant applications of these methods to the analysis of water samples are examined, being wastewater and surface water the most investigated. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Innovative sampling and extraction methods for the determination of nonsteroidal anti-inflammatory drugs in water.

    Science.gov (United States)

    Tanwar, Shivani; Di Carro, Marina; Magi, Emanuele

    2015-03-15

    Two different innovative approaches were used for the determination of nonsteroidal anti-inflammatory drugs (NSAIDs) in water: stir bar sorptive extraction (SBSE) and passive sampling, followed by electrospray ionization liquid chromatography-tandem mass spectrometry. SBSE was developed by comparing EG-Silicone and PDMS stir bars and optimizing main parameters to attain high preconcentration. Quantitative analysis was carried out by mass spectrometry in negative ionization mode and multiple reaction monitoring. The SBSE-LC-MS/MS method provided satisfactory figures of merit with LOD (7.5-71 ng L(-1)) and LOQ (22.5-213 ng L(-1)). The developed method was successfully applied to real samples collected from river water and wastewater effluents. The obtained results showed the presence of all analytes at trace levels, in a wide range of concentrations. The passive sampling approach was carried out by using Polar Organic Chemical Integrative Sampler (POCIS); samplers were deployed for 15 days in river and tap water, allowing to detect analytes at ultra-trace levels. Time-Weighted Average concentration of NSAIDs in river water was estimated in the range 0.33-0.46 ng L(-1), using the sampling rates previously obtained by means of a simple calibration system. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Development of a double containment concept for the European pressurized water reactor

    International Nuclear Information System (INIS)

    Costaz, J.L.; Bonhomme, N.; L'Huby, Y.; Sidaner, J.F.

    1994-01-01

    This paper addresses the development of a double containment concept for the European Pressurized Water Reactor. Specification of containment leak tightness during severe hazards resulting from core melt scenarios is part of the safety goals defined for the EPR project. These safety goals include retention of molten core, mitigation of hydrogen deflagration or explosion risks and decay heat removal. The main new containment structural design loads which have been defined, including containment pressure and temperature conditions following possible postulated-core melt events, are recalled in the paper. The feasibility of a double containment with a prestressed concrete inner containment taking into account these new design loads but based upon experience gained within the well tested concept of concrete double wall containment used in 1400 MW nuclear power plants which have already been built in France, is presented. The main characteristics of such a prestressed inner containment are described. Limits and further possible optimization for even more severe design loads (including liner option) are indicated. Experimental works including a large scale mock up are already under way. (author). 2 refs., 4 figs

  16. The EU Nitrates Directive: A European Approach to Combat Water Pollution from Agriculture

    Directory of Open Access Journals (Sweden)

    Gert J. Monteny

    2001-01-01

    Full Text Available From 1991 onward, the European Union (EU member states have had to comply with the Nitrates Directive. The aim of this directive is to sustainably protect ground and surface waters from pollution with nitrogen (nitrate originating from agriculture. Agriculture is, on an EU level, the largest single source of nitrate (runoff, leaching pollution, although households and industries also contribute to some extent. An important element in the directive is the reporting every 4 years on the monitoring of ground- and surface-water quality. Furthermore, all 15 member states are compelled to designate so-called Nitrate Vulnerable Zones (NVZs. These are regions where the nitrate concentrations in the groundwater amount to 50 mg/l or more. In addition to Codes of Good Agricultural Practice, valid on a countrywide basis and often consisting of voluntary-based measures, specific Action Programmes with mandatory measures have to be developed for the NVZs. The first reporting period ended in 1995. This paper describes the progress in member states’ compliance with the Nitrates Directive during the second period (1996–1999, with a focus on the agricultural practices and action pro- grammes. An evaluation of the member states’ reports shows that good progress is being made on the farmers’ awareness of the need to comply with EU regulations on the protection of the aquatic environment. Action programmes are valuable tools to enforce measures that lead to a reduction of the water pollution by agricultural activities. Regional projects show that significant improvements can be achieved (e.g., reduced fertiliser inputs while maintaining crop yields and thus maintaining the economic potential of agriculture.

  17. Evaluating Sex and Age Differences in ADI-R and ADOS Scores in a Large European Multi-Site Sample of Individuals with Autism Spectrum Disorder

    Science.gov (United States)

    Tillmann, J.; Ashwood, K.; Absoud, M.; Bölte, S.; Bonnet-Brilhault, F.; Buitelaar, J. K.; Calderoni, S.; Calvo, R.; Canal-Bedia, R.; Canitano, R.; De Bildt, A.; Gomot, M.; Hoekstra, P. J.; Kaale, A.; McConachie, H.; Murphy, D. G.; Narzisi, A.; Oosterling, I.; Pejovic-Milovancevic, M.; Persico, A. M.; Puig, O.; Roeyers, H.; Rommelse, N.; Sacco, R.; Scandurra, V.; Stanfield, A. C.; Zander, E.; Charman, T.

    2018-01-01

    Research on sex-related differences in Autism Spectrum Disorder (ASD) has been impeded by small samples. We pooled 28 datasets from 18 sites across nine European countries to examine sex differences in the ASD phenotype on the ADI-R (376 females, 1763 males) and ADOS (233 females, 1187 males). On the ADI-R, early childhood restricted and…

  18. Something Old, Something New, Something Borrowed and Something Blue
    Tackling Diffuse Water Pollution from Agriculture in China: Drawing Inspiration from the European Union

    Directory of Open Access Journals (Sweden)

    Liping Dai

    2014-05-01

    Full Text Available Diffuse water pollution caused by agriculture is increasingly recognized as a major contributor to water pollution both in China and in Europe. A great deal of effort has been spent on mechanisms to address such pollution, especially through legislation and policy. The legal challenge for China is to develop an adequate legal framework to tackle diffuse pollution. By providing an overview of the current policy design regarding diffuse water pollution management in both China and the European Union, this article discusses the extent to which the EU legal framework could provide inspiration for China.

  19. Determination of some organophosphorus pesticides in water and watermelon samples by microextraction prior to high-performance liquid chromatography.

    Science.gov (United States)

    Wang, Chun; Wu, Qiuhua; Wu, Chunxia; Wang, Zhi

    2011-11-01

    A novel method based on simultaneous liquid-liquid microextraction and carbon nanotube reinforced hollow fiber microporous membrane solid-liquid phase microextraction has been developed for the determination of six organophosphorus pesticides, i.e. isocarbophos, phosmet, parathion-methyl, triazophos, fonofos and phoxim, in water and watermelon samples prior to high-performance liquid chromatography (HPLC). Under the optimum conditions, the method shows a good linearity within a range of 1-200 ng/mL for water samples and 5-200 ng/g for watermelon samples, with the correlation coefficients (r) varying from 0.9990 to 0.9997 and 0.9986 to 0.9995, respectively. The limits of detection (LODs) were in the range between 0.1 and 0.3 ng/mL for water samples and between 1.0 and 1.5 ng/g for watermelon samples. The recoveries of the method at spiking levels of 5.0 and 50.0 ng/mL for water samples were between 85.4 and 100.8%, and at spiking levels of 5.0 and 50.0 ng/g for watermelon samples, they were between 82.6 and 92.4%, with the relative standard deviations (RSDs) varying from 4.5-6.9% and 5.2-7.4%, respectively. The results suggested that the developed method represents a simple, low-cost, high analytes preconcentration and excellent sample cleanup procedure for the determination of organophosphorus pesticides in water and watermelon samples. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Development of a novel method for simultaneous concentration of viruses and protozoa from a single water sample.

    Science.gov (United States)

    Haramoto, Eiji; Katayama, Hiroyuki; Asami, Mari; Akiba, Michihiro

    2012-06-01

    A novel method, electronegative membrane-vortex (EMV) method, was developed for simultaneous concentration of viruses and protozoa from a single water sample. Viruses and protozoa in a water sample were mixed with a cation solution and adsorbed on an electronegative membrane. Concentrated virus and protozoa samples were obtained as supernatant and pellet fractions, respectively, by vigorous vortex mixing of the membrane and centrifugation of the eluted material. The highest recovery efficiencies of model microbes from river water and tap water by this EMV method were obtained using a mixed cellulose ester membrane with a pore size of 0.45 μm (Millipore) as the electronegative membrane and MgCl(2) as the cation solution. The recovery was 27.7-86.5% for poliovirus, 25.7-68.3% for coliphage Qβ, 28.0-60.0% for Cryptosporidium oocysts, and 35.0-53.0% for Giardia cysts. The EMV method detected successfully indigenous viruses and protozoa in wastewater and river water samples from the Kofu basin, Japan, showing an overall positive rate of 100% (43/43) for human adenovirus, 79% (34/43) for norovirus GI, 65% (28/43) for norovirus GII, 23% (10/43) for Cryptosporidium oocysts, and 60% (26/43) for Giardia cysts. By direct DNA sequencing, a total of four genotypes (AI, AII, B, and G) of Giardia intestinalis were identified in the water samples, indicating that the river water was contaminated with feces from various mammals, including humans. Copyright © 2012 Elsevier B.V. All rights reserved.