WorldWideScience

Sample records for equivalence ratio measurements

  1. Measurement of the tissue to A-150 tissue equivalent plastic kerma ratio at two p(66)Be neutron therapy facilities

    International Nuclear Information System (INIS)

    Langen, K M; Binns, P J; Schreuder, A N; Lennox, A J; Deluca, P M Jr.

    2003-01-01

    The ICRU tissue to A-150 tissue equivalent plastic kerma ratio is needed for neutron therapy dosimetry. The current ICRU protocol for neutron dosimetry recommends using a common conversion factor of 0.95 at all high-energy neutron therapy facilities. In an effort to determine facility specific ICRU tissue to A-150 plastic kerma ratios, an experimental approach was pursued. Four low pressure proportional counters that differed in wall materials (i.e. A-150, carbon, zirconium and zirconium-oxide) were used as dosimeters and integral kerma ratios were determined directly in the clinical beam. Measurements were performed at two p(66)Be facilities: iThemba LABS near Cape Town and Fermilab near Chicago. At the iThemba facility the clinical neutron beam is routinely filtered by a flattening and hardening filter combination. The influence of beam filtration on the kerma ratio was evaluated. Using two recent gas-to-wall dose conversion factor (r m,g value) evaluations a mean ICRU tissue to A-150 plastic kerma ratio of 0.93 ± 0.05 was determined for the clinical beam at iThemba LABS. The respective value for the Fermilab beam is 0.95 ± 0.05. The experimentally determined ICRU tissue to A-150 plastic kerma ratios for the two clinical beams are in agreement with theoretical evaluations. Beam filtration reduces the kerma ratio by 3 ± 2%

  2. Equivalence ratio and constriction effects on RBCC thrust augmentation

    Science.gov (United States)

    Koupriyanov, M.; Etele, J.

    2011-06-01

    A theoretical analysis of a variable area rocket based combined cycle engine with and without simultaneous mixing and combustion is presented. The flowfield is solved using a steady, quasi-one-dimensional, inviscid control volume formulation with combustion effects included via a generalized equilibrium calculation. Compression augmentation is shown to be sensitive to the equivalence ratio within the primary rocket chamber, where ejector section performance is greatest at both low and high equivalence ratios but near a minimum at stoichiometric conditions. The thrust generated by the RBCC engine compared to that generated by the same rocket in isolation can be increased by as much as 12% at constriction ratios of between 45% and 50%. Thrust augmentation is also shown to vary with equivalence ratio, where for a fixed geometry the maximum thrust is generated at equivalence ratios slightly below unity.

  3. Chemiluminescence-based multivariate sensing of local equivalence ratios in premixed atmospheric methane-air flames

    Energy Technology Data Exchange (ETDEWEB)

    Tripathi, Markandey M.; Krishnan, Sundar R.; Srinivasan, Kalyan K.; Yueh, Fang-Yu; Singh, Jagdish P.

    2011-09-07

    Chemiluminescence emissions from OH*, CH*, C2, and CO2 formed within the reaction zone of premixed flames depend upon the fuel-air equivalence ratio in the burning mixture. In the present paper, a new partial least square regression (PLS-R) based multivariate sensing methodology is investigated and compared with an OH*/CH* intensity ratio-based calibration model for sensing equivalence ratio in atmospheric methane-air premixed flames. Five replications of spectral data at nine different equivalence ratios ranging from 0.73 to 1.48 were used in the calibration of both models. During model development, the PLS-R model was initially validated with the calibration data set using the leave-one-out cross validation technique. Since the PLS-R model used the entire raw spectral intensities, it did not need the nonlinear background subtraction of CO2 emission that is required for typical OH*/CH* intensity ratio calibrations. An unbiased spectral data set (not used in the PLS-R model development), for 28 different equivalence ratio conditions ranging from 0.71 to 1.67, was used to predict equivalence ratios using the PLS-R and the intensity ratio calibration models. It was found that the equivalence ratios predicted with the PLS-R based multivariate calibration model matched the experimentally measured equivalence ratios within 7%; whereas, the OH*/CH* intensity ratio calibration grossly underpredicted equivalence ratios in comparison to measured equivalence ratios, especially under rich conditions ( > 1.2). The practical implications of the chemiluminescence-based multivariate equivalence ratio sensing methodology are also discussed.

  4. Mixed field dose equivalent measuring instruments

    International Nuclear Information System (INIS)

    Brackenbush, L.W.; McDonald, J.C.; Endres, G.W.R.; Quam, W.

    1985-01-01

    In the past, separate instruments have been used to monitor dose equivalent from neutrons and gamma rays. It has been demonstrated that it is now possible to measure simultaneously neutron and gamma dose with a single instrument, the tissue equivalent proportional counter (TEPC). With appropriate algorithms dose equivalent can also be determined from the TEPC. A simple ''pocket rem meter'' for measuring neutron dose equivalent has already been developed. Improved algorithms for determining dose equivalent for mixed fields are presented. (author)

  5. Simultaneous equivalence ratio and velocity measurements for non-stationary combustion study in a stratified flow; Mesures couplees de richesse et de vitesse pour la combustion instationnaire en ecoulement stratifie

    Energy Technology Data Exchange (ETDEWEB)

    Pasquier-Guilbert, N

    2004-12-15

    Simultaneous knowledge of local velocity and equivalence ratio is very important in numerous combustion applications and especially for direct injection engines where the flame propagates through a heterogeneous concentration distribution of fuel-air mixture. This study reproduce heterogeneities of equivalence ratio with propane and air in a constant volume combustion vessel. The local influence of velocity and equivalence ratio on the propagation of a spark-ignited flame is studied. To create a stratification, a rich axisymmetric pulsed jet is injected in a leaner chamber and the mixing is ignited. Two optical diagnostics are used simultaneously, PIV for velocity and FARLIF for equivalence ratio, with or without combustion. All properties and range of applications of PIV and FARLIF have been verified. These methods were then used to study the characteristics of stratified combustion. (author)

  6. Possibility and necessity measures and integral equivalence

    Czech Academy of Sciences Publication Activity Database

    Chen, T.; Mesiar, Radko; Li, J.; Stupňanová, A.

    2017-01-01

    Roč. 86, č. 1 (2017), s. 62-72 ISSN 0888-613X Institutional support: RVO:67985556 Keywords : Integral equivalence * Necessity measure * Possibility measure * Survival function * Universal integral Subject RIV: BA - General Mathematics OBOR OECD: Statistics and probability Impact factor: 2.845, year: 2016 http://library.utia.cas.cz/separaty/2017/E/mesiar-0477092.pdf

  7. Measurements of the personal dose equivalent

    International Nuclear Information System (INIS)

    Scarlat, F.; Scarisoreanu, A.; Badita, E.; Oane, M.; Mitru, E.

    2008-01-01

    Full text: The paper presents the results of measurements related to the personal dose equivalent in the rooms adjacent to NILPRP 7 MeV linear accelerator, by means of the secondary standard chamber T34035 Hp(10). The chamber was calibrated by PTB at S- 137 Cs (E av = 661.6 keV, T 1/2 11050 days) and has N H = 3.17x10 6 Sv/C calibration factor for the personal dose equivalent, Hp(10), at a depth of 10 mm in climatic reference conditions. The measurements were made for the two operation mode of the 7 MeV linac: electrons and bremsstrahlung

  8. Response of partially premixed flames to acoustic velocity and equivalence ratio perturbations

    Energy Technology Data Exchange (ETDEWEB)

    Kim, K.T.; Lee, J.G.; Quay, B.D.; Santavicca, D.A. [Center for Advanced Power Generation, Department of Mechanical and Nuclear Engineering, The Pennsylvania State University, University Park, PA (United States)

    2010-09-15

    This article describes an experimental investigation of the forced response of a swirl-stabilized partially premixed flame when it is subjected to acoustic velocity and equivalence ratio fluctuations. The flame's response is analyzed using phase-resolved CH{sup *} chemiluminescence images and flame transfer function (FTF) measurements, and compared with the response of a perfectly premixed flame under acoustic perturbations. The nonlinear response of the partially premixed flame is manifested by a partial extinction of the reaction zone, leading to rapid reduction of flame surface area. This nonlinearity, however, is observed only when the phase difference between the acoustic velocity and the equivalence ratio at the combustor inlet is close to zero. The condition, {delta}{phi}{sub {phi}}'-V'{approx}0 , indicates that reactant mixtures with high equivalence ratio impinge on the flame front with high velocity, inducing large fluctuations of the rate of heat release. It is found that the phase difference between the acoustic velocity and equivalence ratio nonuniformities is a key parameter governing the linear/nonlinear response of a partially premixed flame, and it is a function of modulation frequency, inlet velocity, fuel injection location, and fuel injector impedance. The results presented in this article will provide insight into the response of a partially premixed flame, which has not been well explored to date. (author)

  9. The equivalent pore aspect ratio as a tool for pore type prediction in carbonate reservoirs

    OpenAIRE

    FOURNIER , François; Pellerin , Matthieu; Villeneuve , Quentin; Teillet , Thomas; Hong , Fei; Poli , Emmanuelle; Borgomano , Jean; Léonide , Philippe; Hairabian , Alex

    2018-01-01

    International audience; The equivalent pore aspect ratios (EPAR) provide a tool to detect pore types by combining P-and S-wave velocities, porosity, bulk density and mineralogical composition of carbonate rocks. The integration of laboratory measurements, well log data and petrographic analysis of 468 carbonate samples from various depositional and diagenetic settings (Lower Cretaceous pre-salt non-marine carbonates from offshore Brazil, Lower Cretaceous shallow-water platform carbonates from...

  10. Periodic equivalence ratio modulation method and apparatus for controlling combustion instability

    Science.gov (United States)

    Richards, George A.; Janus, Michael C.; Griffith, Richard A.

    2000-01-01

    The periodic equivalence ratio modulation (PERM) method and apparatus significantly reduces and/or eliminates unstable conditions within a combustion chamber. The method involves modulating the equivalence ratio for the combustion device, such that the combustion device periodically operates outside of an identified unstable oscillation region. The equivalence ratio is modulated between preselected reference points, according to the shape of the oscillation region and operating parameters of the system. Preferably, the equivalence ratio is modulated from a first stable condition to a second stable condition, and, alternatively, the equivalence ratio is modulated from a stable condition to an unstable condition. The method is further applicable to multi-nozzle combustor designs, whereby individual nozzles are alternately modulated from stable to unstable conditions. Periodic equivalence ratio modulation (PERM) is accomplished by active control involving periodic, low frequency fuel modulation, whereby low frequency fuel pulses are injected into the main fuel delivery. Importantly, the fuel pulses are injected at a rate so as not to affect the desired time-average equivalence ratio for the combustion device.

  11. Application of A150-plastic equivalent gases in microdosimetric measurements

    International Nuclear Information System (INIS)

    DeLuca, P.M. Jr.; Higgins, P.D.; Pearson, D.W.; Schell, M.; Attix, F.H.

    1981-01-01

    Neutron dosimetry measurements with ionization chambers, for the most part, employ tissue equivalent plastic-walled cavities (Shonka A150) filled with either air or a methane-base tissue-like gas. The atomic composition of TE-gas and A150 plastic are not matched and are quite dissimilar from muscle. Awschalom and Attix (1980) have partially resolved the problem by formulating a novel A150-plastic equivalent gas. This establishes a homogeneous wall-gas cavity dosimeter for neutron measurements and confines the necessary corrections to the applications of kerma ratios. In this report, we present measurements of applications of two A150-plastic equivalent gases in a low pressure spherical proportional counter. Gas gains and alpha-particle resolutions were determined. For these A150-mixtures as well as a methane-based TE-gas and an Ar-CO 2 mixture, we report measurements of event size distributions from exposure to a beam of 14.8 MeV neutrons

  12. Reproducibility of isotope ratio measurements

    International Nuclear Information System (INIS)

    Elmore, D.

    1981-01-01

    The use of an accelerator as part of a mass spectrometer has improved the sensitivity for measuring low levels of long-lived radionuclides by several orders of magnitude. However, the complexity of a large tandem accelerator and beam transport system has made it difficult to match the precision of low energy mass spectrometry. Although uncertainties for accelerator measured isotope ratios as low as 1% have been obtained under favorable conditions, most errors quoted in the literature for natural samples are in the 5 to 20% range. These errors are dominated by statistics and generally the reproducibility is unknown since the samples are only measured once

  13. Risk measurement with equivalent utility principles

    NARCIS (Netherlands)

    Denuit, M.; Dhaene, J.; Goovaerts, M.; Kaas, R.; Laeven, R.

    2006-01-01

    Risk measures have been studied for several decades in the actuarial literature, where they appeared under the guise of premium calculation principles. Risk measures and properties that risk measures should satisfy have recently received considerable attention in the financial mathematics

  14. Dynamic equivalence relation on the fuzzy measure algebras

    Directory of Open Access Journals (Sweden)

    Roya Ghasemkhani

    2017-04-01

    Full Text Available The main goal of the present paper is to extend classical results from the measure theory and dynamical systems to the fuzzy subset setting. In this paper, the notion of  dynamic equivalence relation is introduced and then it is proved that this relation is an equivalence relation. Also, a new metric on the collection of all equivalence classes is introduced and it is proved that this metric is complete.

  15. School Principals' Leadership Skills: Measurement Equivalence across Cultures

    Science.gov (United States)

    Da'as, Rima'a

    2017-01-01

    Despite substantial interest and research in measuring leader's skills, little is known about the measurement equivalence and mean differences in the scores measuring principals' skills (cognitive, interpersonal, strategic) across cultures (collectivism versus individualism). The aim of the present study was to assess measurement…

  16. Skin Dose Equivalent Measurement from Neutron-Deficient Isotopes

    International Nuclear Information System (INIS)

    Hsu, Hsiao-Hua; Costigan, Steve A.; Romero, Leonard L.; Whicker, Jeffrey J.

    1997-12-01

    Neutron-deficient-isotopes decay via positron emission and/or electron capture often followed by x-ray, gamma-ray, and 0.511 MeV photons from positron annihilation. For cases of significant area and/or personnel contamination with these isotopes, determination of skin dose equivalent (SDE) is required by 10CFR835. For assessment of SDE, we evaluated the MICROSPEC-2(TM) system manufactured by Bubble Technology Industries of Canada which uses three different probes for dose measurement. We used two probes: (1) the X-probe which measures lower energy (4 - 120 keV) photon energy distributions and determines deep dose equivalent, SDE and dose equivalent to eyes, and (2) the B-probe which measures electron (positron) energy distributions, and determines skin dose equivalent. Also, the measured photon and beta spectra can be used to identify radioactive isotopes in the contaminated area. Measurements with several neutron-deficient sources showed that this system provided reasonably accurate SDE rate measurements when compared with calculated benchmark SDE rates with an average percent difference of 40%. Variations were expected because of differences between the assumed geometries used by MlCROSPEC-2 and the calculations when compared to the measurement conditions

  17. Estimation of equivalence ratio distribution in diesel spray using a computational fluid dynamics

    Science.gov (United States)

    Suzuki, Yasumasa; Tsujimura, Taku; Kusaka, Jin

    2014-08-01

    It is important to understand the mechanism of mixing and atomization of the diesel spray. In addition, the computational prediction of mixing behavior and internal structure of a diesel spray is expected to promote the further understanding about a diesel spray and development of the diesel engine including devices for fuel injection. In this study, we predicted the formation of diesel fuel spray with 3D-CFD code and validated the application by comparing experimental results of the fuel spray behavior and the equivalence ratio visualized by Layleigh-scatter imaging under some ambient, injection and fuel conditions. Using the applicable constants of KH-RT model, we can predict the liquid length spray on a quantitative level. under various fuel injection, ambient and fuel conditions. On the other hand, the change of the vapor penetration and the fuel mass fraction and equivalence ratio distribution with change of fuel injection and ambient conditions quantitatively. The 3D-CFD code used in this study predicts the spray cone angle and entrainment of ambient gas are predicted excessively, therefore there is the possibility of the improvement in the prediction accuracy by the refinement of fuel droplets breakup and evaporation model and the quantitative prediction of spray cone angle.

  18. Is the dose equivalent index a quantity to be measured

    International Nuclear Information System (INIS)

    Wagner, S.R.

    1980-01-01

    ICRP introduced the concept of Effective Dose Equivalent H(sub)E and fixed the basic limits of radiation exposure in terms of H(sub)I. As H(sub)E cannot be measured, ICRP stated that with external exposure to penetrating radiation the limitation of the Dose Equivalent Index H(sub)I would afford at least as good a level of protection. However, difficulties arise in measuring H(sub)I and in calibrating instruments in terms of H(sub)I, since the height and location of the dose equivalent maximum in the sphere which is the phantom used in the definition of H(sub)I, depend on the energy and the angular distribution of the incident radiation. That is, H(sub)I is not an additive quantity relative to the partial H(sub)I(sub)i-values of the different energy and angular components. Hence, 1) the distribution of dose equivalent in the sphere must be measured in full for a determination of H(sub)I, and 2) it is not possible to calibrate an instrument which does not exhibit the scattering and absorption properties of the sphere, consistently for arbitrary radiation fields in terms of H(sub)I. Thus the calibration in an unidirectional beam would infer an uncertainty which may amount to a factor of up to 4. This would hardly be tolerable as a base for radiation protection provisions. An alternative is to introduce operational quantities which are additive, e.g. 1) the sum of maxima of the dose equivalent distributions in the sphere produced by different radiation components, and 2) the mean dose equivalent in the sphere. Their relation to H(sub)E for different types of radiation and consequences on secondary limits are discussed. (H.K.)

  19. An experimental and numerical analysis of the influence of the inlet temperature, equivalence ratio and compression ratio on the HCCI auto-ignition process of Primary Reference Fuels in an engine

    OpenAIRE

    Machrafi, Hatim; Cavadias

    2008-01-01

    In order to understand better the auto-ignition process in an HCCI engine, the influence of some important parameters on the auto-ignition is investigated. The inlet temperature, the equivalence ratio and the compression ratio were varied and their influence on the pressure, the heat release and the ignition delays were measured, The inlet temperature was changed from 25 to 70 degrees C and the equivalence ratio from 0.18 to 0.41, while the compression ratio varied from 6 to 13.5. The fuels t...

  20. THE EFFECTS OF EQUIVALENCE RATIO ON THE FORMATION OF POLYCYCLIC AROMATIC HYDROCARBONS AND SOOT IN PREMIXED ETHANE FLAMES. (R825412)

    Science.gov (United States)

    AbstractThe formation of polycyclic aromatic hydrocarbons (PAH) and soot has been investigated in atmospheric-pressure, laminar, ethane/oxygen/argon premixed flames as a function of mixture equivalence ratio. Mole fraction profiles of major products, trace aromatics, ...

  1. Lay understanding of forensic statistics: Evaluation of random match probabilities, likelihood ratios, and verbal equivalents.

    Science.gov (United States)

    Thompson, William C; Newman, Eryn J

    2015-08-01

    Forensic scientists have come under increasing pressure to quantify the strength of their evidence, but it is not clear which of several possible formats for presenting quantitative conclusions will be easiest for lay people, such as jurors, to understand. This experiment examined the way that people recruited from Amazon's Mechanical Turk (n = 541) responded to 2 types of forensic evidence--a DNA comparison and a shoeprint comparison--when an expert explained the strength of this evidence 3 different ways: using random match probabilities (RMPs), likelihood ratios (LRs), or verbal equivalents of likelihood ratios (VEs). We found that verdicts were sensitive to the strength of DNA evidence regardless of how the expert explained it, but verdicts were sensitive to the strength of shoeprint evidence only when the expert used RMPs. The weight given to DNA evidence was consistent with the predictions of a Bayesian network model that incorporated the perceived risk of a false match from 3 causes (coincidence, a laboratory error, and a frame-up), but shoeprint evidence was undervalued relative to the same Bayesian model. Fallacious interpretations of the expert's testimony (consistent with the source probability error and the defense attorney's fallacy) were common and were associated with the weight given to the evidence and verdicts. The findings indicate that perceptions of forensic science evidence are shaped by prior beliefs and expectations as well as expert testimony and consequently that the best way to characterize and explain forensic evidence may vary across forensic disciplines. (c) 2015 APA, all rights reserved).

  2. Impact of Equivalence Ratio on the Macrostructure of Premixed Swirling CH 4 /Air and CH 4 /O 2 /CO 2 Flames

    KAUST Repository

    Watanabe, Hirotatsu

    2015-06-15

    Premixed CH4/O2/CO2 flames (oxy-flames) and CH4/air flames (air-flames) were experimentally studied in a swirl-stabilized combustor. For comparing oxy and air flames, the same equivalence ratio and adiabatic flame temperature were used. CO2 dilution was adjusted to attain the same adiabatic temperature for the oxy-flame and the corresponding air-flame while keeping the equivalence ratio and Reynolds number (=20,000) the same. For high equivalence ratios, we observed flames stabilized along the inner and outer shear layers of the swirling flow and sudden expansion, respectively, in both flames. However, one notable difference between the two flames appears as the equivalence ratio reaches 0.60. At this point, the outer shear layer flame disappears in the air-flame while it persists in the oxy-flame, despite the lower burning velocity of the oxy-flame. Prior PIV measurements (Ref. 9) showed that the strains along the outer shear layer are higher than along the inner shear layer. Therefore, the extinction strain rates in both flames were calculated using a counter-flow premixed twin flame configuration. Calculations at the equivalence ratio of 0.60 show that the extinction strain rate is higher in the oxy than in the air flame, which help explain why it persists on the outer shear layer with higher strain rate. It is likely that extinction strain rates contribute to the oxy-flame stabilization when air flame extinguish in the outer shear layer. However, the trend reverses at higher equivalence ratio, and the cross point of the extinction strain rate appears at equivalence ratio of 0.64.

  3. Annual Equivalent Value, Benefit Cost Ratio, and Composite Performance Index as Valuation Appraisal Support of Teakwood Plantation

    Directory of Open Access Journals (Sweden)

    Sugiharto Soeleman

    2014-04-01

    Full Text Available Teak (Tectona grandis L.f is a premium high-value hardwood species being viewed as the most preferred species for investment opportunity. Recently, there has been a gradual move away from state control of teakwood plantation toward the participation of private enterprises. Several enterprises offer investment opportunity of teakwood plantation in which one of the main selling points being offered is a quick harvesting schedule. A quick harvesting time, however, might not provide the best outcome to the investors. This research exercise and compare the valuation appraisal of different harvesting schedules. The research focused on project planning, enterprise budget, financial projection, and valuation measurements to arrive at overall appraisal. To avoid any possible bias of individual investor's preference on common valuation criteria such as total investment, net cash flow (NCF, net present value (NPV, internal rate of return (IRR, profit on investment (P/I, and payback period (PBP, 3 otherS criteria namely benefit cost ratio (BCR, annual equivalent value (AEV, and composite performance index (CPI have been applied to arrive at a more fair valuation. It is concluded that the longer the harvesting schedule, the better valuation outcome could be achieved, and therefore, investors should critically review any investment proposal in accordance to their preference on valuation criteria. Keywords : annual equivalent value, benefit cost ratio, composite performance index, valuation appraisal

  4. Measurement Of Lead Equivalent Thickness For Irradiation Room: An Analysis

    International Nuclear Information System (INIS)

    Mohd Khalid Matori; Azuhar Ripin; Husaini Salleh; Mohd Khairusalih Mohd Zin; Muhammad Jamal Muhd Isa; Mohd Faizal Abdul Rahman

    2014-01-01

    The Malaysian Ministry of Health (MOH) has established that the irradiation room must have a sufficient thickness of shielding to ensure that requirements for the purpose of radiation protection of patients, employees and the public are met. This paper presents a technique using americium-241 source to test and verify the integrity of the shielding thickness in term of lead equivalent for irradiation room at health clinics own by MOH. Results of measurement of 8 irradiation rooms conducted in 2014 were analyzed for this presentation. Technical comparison of the attenuation of gamma rays from Am-241 source through the walls of the irradiation room and pieces of lead were used to assess the lead equivalent thickness of the walls. Results showed that almost all the irradiation rooms tested meet the requirements of the Ministry of Health and is suitable for the installation of the intended diagnostic X-ray apparatus. Some specific positions such as door knobs and locks, electrical plug sockets were identified with potential to not met the required lead equivalent thickness hence may contribute to higher radiation exposure to workers and the public. (author)

  5. Effect of Nickel Equivalent on Austenite Transition Ratio in Ni-Mn-Cu Cast Iron

    Directory of Open Access Journals (Sweden)

    Janus A.

    2013-06-01

    Full Text Available Determined was quantitative effect of nickel equivalent value on austenite decomposition degree during cooling-down castings of Ni-Mn- Cu cast iron. Chemical composition of the alloy was 1.8 to 5.0 % C, 1.3 to 3.0 % Si, 3.1 to 7.7 % Ni, 0.4 to 6.3 % Mn, 0.1 to 4.9 % Cu, 0.14 to 0.16 % P and 0.03 to 0.04 % S. Analysed were castings with representative wall thickness 10, 15 and 20 mm. Scope of the examination comprised chemical analysis (including WDS, microscopic observations (optical and scanning microscopy, image analyser, as well as Brinell hardness and HV microhardness measurements of structural components.

  6. Isotope determinations of renal clearance equivalent with physiological clearance measurements

    International Nuclear Information System (INIS)

    Junges, R.

    1983-01-01

    The concept of renal clearance in nuclear medicine describes the tubular secretion and glomerular filtration of a substance being removed from the blood plasma. The concept of clearance as used physiologically is rather wider and includes consideration of the outflow of the substances remained back in the kidneys. The present paper discusses clearance measurements as seen from a thermodynamic point of view, in which isotope clearances become equivalent with the physiological concept of clearance. In addition, it is possible to quantify each single step of the excretory function of each kidney separately. (orig.) [de

  7. A Study on the Effects of Compression Ratio, Engine Speed and Equivalence Ratio on HCCI Combustion of DME

    DEFF Research Database (Denmark)

    Pedersen, Troels Dyhr; Schramm, Jesper

    2007-01-01

    An experimental study has been carried out on the homogeneous charge compression ignition (HCCI) combustion of Dimethyl Ether (DME). The study was performed as a parameter variation of engine speed and compression ratio on excess air ratios of approximately 2.5, 3 and 4. The compression ratio was...

  8. A Study on the Effects of Compression Ratio, Engine Speed and Equivalence Ratio on HCCI Combustion of DME

    DEFF Research Database (Denmark)

    Pedersen, Troels Dyhr; Schramm, Jesper

    2007-01-01

    An experimental study has been carried out on the homogeneous charge compression ignition (HCCI) combustion of Dimethyl Ether (DME). The study was performed as a parameter variation of engine speed and compression ratio on excess air ratios of approximately 2.5, 3 and 4. The compression ratio...... was adjusted in steps to find suitable regions of operation, and the effect of engine speed was studied at 1000, 2000 and 3000 RPM. It was found that leaner excess air ratios require higher compression ratios to achieve satisfactory combustion. Engine speed also affects operation significantly....

  9. Uranium isotope ratio measurements in field settings

    International Nuclear Information System (INIS)

    Shaw, R.W.; Barshick, C.M.; Young, J.P.; Ramsey, J.M.

    1997-01-01

    The authors have developed a technique for uranium isotope ratio measurements of powder samples in field settings. Such a method will be invaluable for environmental studies, radioactive waste operations, and decommissioning and decontamination operations. Immediate field data can help guide an ongoing sampling campaign. The measurement encompasses glow discharge sputtering from pressed sample hollow cathodes, high resolution laser spectroscopy using conveniently tunable diode lasers, and optogalvanic detection. At 10% 235 U enrichment and above, the measurement precision for 235 U/( 235 U+ 238 U) isotope ratios was ±3%; it declined to ±15% for 0.3% (i.e., depleted) samples. A prototype instrument was constructed and is described

  10. Measuring Poisson Ratios at Low Temperatures

    Science.gov (United States)

    Boozon, R. S.; Shepic, J. A.

    1987-01-01

    Simple extensometer ring measures bulges of specimens in compression. New method of measuring Poisson's ratio used on brittle ceramic materials at cryogenic temperatures. Extensometer ring encircles cylindrical specimen. Four strain gauges connected in fully active Wheatstone bridge self-temperature-compensating. Used at temperatures as low as liquid helium.

  11. Determination of the equivalent intergranular void ratio - Application to the instability and the critical state of silty sand

    Directory of Open Access Journals (Sweden)

    Nguyen Trung-Kien

    2017-01-01

    Full Text Available This paper presents an experimental study of mechanical response of natural Camargue silty sand. The analysis of test results used the equivalent intergranular void ratio instead of the global void ratio. The calculation of equivalent intergranular void ratio requires the determination of parameter b which represents, physically, the fraction of active fines participating on the chain forces network, hence the strength of the soil. A new formula for determining the parameter b by using an approach based on the coordination number distribution and probability calculation is proposed. The validation of the developed relationship was done through back-analysis of published datasets in literature on the effect of fines content on silty sand behavior. It is shown that the equivalent intergranular void ratio calculated with the b value obtained by the new formula is able to provide strong correlation to not only the critical state of but also the onset of instability of various silty sands, in different terms as peak deviator stress, peak stress ratio or cyclic resistance. Therefore, it is suggested that the use of the equivalent void ratio concept and the new b calculating formula is highly desirable in predicting of the silty sand behavior.

  12. Measurement equivalence and differential item functioning in family psychology.

    Science.gov (United States)

    Bingenheimer, Jeffrey B; Raudenbush, Stephen W; Leventhal, Tama; Brooks-Gunn, Jeanne

    2005-09-01

    Several hypotheses in family psychology involve comparisons of sociocultural groups. Yet the potential for cross-cultural inequivalence in widely used psychological measurement instruments threatens the validity of inferences about group differences. Methods for dealing with these issues have been developed via the framework of item response theory. These methods deal with an important type of measurement inequivalence, called differential item functioning (DIF). The authors introduce DIF analytic methods, linking them to a well-established framework for conceptualizing cross-cultural measurement equivalence in psychology (C.H. Hui and H.C. Triandis, 1985). They illustrate the use of DIF methods using data from the Project on Human Development in Chicago Neighborhoods (PHDCN). Focusing on the Caregiver Warmth and Environmental Organization scales from the PHDCN's adaptation of the Home Observation for Measurement of the Environment Inventory, the authors obtain results that exemplify the range of outcomes that may result when these methods are applied to psychological measurement instruments. (c) 2005 APA, all rights reserved

  13. Application of the modified chi-square ratio statistic in a stepwise procedure for cascade impactor equivalence testing.

    Science.gov (United States)

    Weber, Benjamin; Lee, Sau L; Delvadia, Renishkumar; Lionberger, Robert; Li, Bing V; Tsong, Yi; Hochhaus, Guenther

    2015-03-01

    Equivalence testing of aerodynamic particle size distribution (APSD) through multi-stage cascade impactors (CIs) is important for establishing bioequivalence of orally inhaled drug products. Recent work demonstrated that the median of the modified chi-square ratio statistic (MmCSRS) is a promising metric for APSD equivalence testing of test (T) and reference (R) products as it can be applied to a reduced number of CI sites that are more relevant for lung deposition. This metric is also less sensitive to the increased variability often observed for low-deposition sites. A method to establish critical values for the MmCSRS is described here. This method considers the variability of the R product by employing a reference variance scaling approach that allows definition of critical values as a function of the observed variability of the R product. A stepwise CI equivalence test is proposed that integrates the MmCSRS as a method for comparing the relative shapes of CI profiles and incorporates statistical tests for assessing equivalence of single actuation content and impactor sized mass. This stepwise CI equivalence test was applied to 55 published CI profile scenarios, which were classified as equivalent or inequivalent by members of the Product Quality Research Institute working group (PQRI WG). The results of the stepwise CI equivalence test using a 25% difference in MmCSRS as an acceptance criterion provided the best matching with those of the PQRI WG as decisions of both methods agreed in 75% of the 55 CI profile scenarios.

  14. Ratio method of measuring W boson mass

    Energy Technology Data Exchange (ETDEWEB)

    Guo, Feng [Stony Brook Univ., NY (United States)

    2010-08-01

    This dissertation describes an alternative method of measuring the W boson mass in DØ experiment. Instead of extracting MW from the fitting of W → ev fast Monte Carlo simulations to W → ev data as in the standard method, we make the direct fit of transverse mass between W → ev data and Z → ee data. One of the two electrons from Z boson is treated as a neutrino in the calculation of transverse mass. In ratio method, the best fitted scale factor corresponds to the ratio of W and Z boson mass (MW/MZ). Given the precisely measured Z boson mass, W mass is directly fitted from W → ev and Z → ee data. This dissertation demonstrates that ratio method is a plausible method of measuring the W boson mass. With the 1 fb-1 DØ Run IIa dataset, ratio method gives MW = 80435 ± 43(stat) ± 26(sys) MeV.

  15. Effect of Temperature, Pressure and Equivalence Ratio on Ignition Delay in Ignition Quality Tester (IQT): Diesel,n-Heptane, andiso-Octane Fuels under Low Temperature Conditions

    KAUST Repository

    Yang, Seung Yeon

    2015-11-02

    Effects of temperature, pressure and global equivalence ratio on total ignition delay time in a constant volume spray combustion chamber were investigated for diesel fuel along with the primary reference fuels (PRFs) of n-heptane and iso-octane in relatively low temperature conditions to simulate unsteady spray ignition behavior. A KAUST Research ignition quality tester (KR-IQT) was utilized, which has a feature of varying temperature, pressure and equivalence ratio using a variable displacement fuel pump. A gradient method was adopted in determining the start of ignition in order to compensate pressure increase induced by low temperature heat release. Comparison of this method with other existing methods was discussed. Ignition delay times were measured at various equivalence ratios (0.5-1.7) with the temperatures of initial charge air in the range from 698 to 860 K and the pressures in the range of 1.5 to 2.1 MPa, pertinent to low temperature combustion (LTC) conditions. An attempt to scale the effect of pressure on total ignition delay was undertaken and the equivalence ratio exponent and activation energy in the Arrhenius expression of total ignition delay were determined. Ignition delay results indicated that there were strong correlations of pressure, temperature, and equivalence ratio under most conditions studied except at relatively low pressures. Diesel (DCN 52.5) and n-heptane (DCN 54) fuels exhibited reasonably similar ignition delay characteristics, while iso-octane showed a distinct behavior under low temperature regime having a two-stage ignition, which substantiate the adoption of the gradient method in determining ignition delay.

  16. Annual Equivalent Value, Benefit Cost Ratio, and Composite Performance Index as Valuation Appraisal Support of Teakwood Plantation

    Directory of Open Access Journals (Sweden)

    Sugiharto Soeleman

    2014-04-01

    Full Text Available Teak (Tectona grandis L.f is a premium high-value hardwood species being viewed as the most preferred species for investment opportunity. Recently, there has been a gradual move away from state control of teakwood plantation toward the participation of private enterprises. Several enterprises offer investment opportunity of teakwood plantation in which one of the main selling points being offered is a quick harvesting schedule. A quick harvesting time, however, might not provide the best outcome to the investors. This research exercise and compare the valuation appraisal of different harvesting schedules. The research focused on project planning, enterprise budget, financial projection, and valuation measurements to arrive at overall appraisal. To avoid any possible bias of individual investor's preference on common valuation criteria such as total investment, net cash flow (NCF, net present value (NPV, internal rate of return (IRR, profit on investment (P/I, and payback period (PBP, 3 otherS criteria namely benefit cost ratio (BCR, annual equivalent value (AEV, and composite performance index (CPI have been applied to arrive at a more fair valuation. It is concluded that the longer the harvesting schedule, the better valuation outcome could be achieved, and therefore, investors should critically review any investment proposal in accordance to their preference on valuation criteria.

  17. Application of the high-temperature ratio method for evaluation of the depth distribution of dose equivalent in a water-filled phantom on board space station Mir

    International Nuclear Information System (INIS)

    Berger, T.; Hajek, M.; Schoener, W.; Fugger, M.; Vana, N.; Akatov, Y.; Shurshakov, V.; Arkhangelsky, V.; Kartashov, D.

    2002-01-01

    A water-filled tissue equivalent phantom with a diameter of 35 cm was developed at the Institute for Biomedical Problems, Moscow, Russia. It contains four channels perpendicular to each other, where dosemeters can be exposed at different depths. Between May 1997 and February 1999 the phantom was installed at three different locations on board the Mir space station. Thermoluminescence dosemeters (TLDs) were exposed at various depths inside the phantom either parallel or perpendicular to the hull of the spacecraft. The high-temperature ratio (HTR) method was used for the evaluation of the TLDs. The method was developed at the Atominstitute of the Austrian Universities, Vienna, Austria, and has already been used for measurements in mixed radiation fields on earth and in space with great success. It uses the changes of peak height ratios in LiF:Mg,Ti glow curves in dependence on the linear energy transfer (LET), and therefore allows determination of an 'averaged' LET as well as measurement of the absorbed dose. A mean quality factor and, subsequently, the dose equivalent can be calculated according to the Q(LET ( ) relationship proposed by the ICRP. The small size of the LiF dosemeters means that the HTR method can be used to determine the gradient of absorbed dose and dose equivalent inside the tissue equivalent body. (author)

  18. Neutron measurements with a tissue-equivalent phantom

    Energy Technology Data Exchange (ETDEWEB)

    Smith, J W [Health Physics Division, Atomic Energy Establishment, Harwell (United Kingdom)

    1962-03-15

    This Appendix 3E of the dosimetry experiment at the R-B reactor describes the apparatus used and presents the obtained results. The phantom used was a 1/4-inch thick polythene container, 60 cm high, of elliptical cross-section, with a major axis of 36 cm and a minor axis of 20 cm. This was filled with an approximately tissue-equivalent liquid. A light but rigid internal framework of Perspex supported a series of small detectors through the phantom. The detectors used in the first high-level run at Vinca, to measure flux above 0.5 MeV, were 0.5-cm wide track plates wrapped in cadmium foil. Each track plate was a sandwich of two Ilford El 50 - mu emulsions, with glass backing, separated by a 250-mu polythene radiator, and was oriented at an angle of 45 deg to the front surface of the phantom. Under these conditions the response is constant with neutron energy between 0.5 MeV and 8 MeV at 1.26 X 10 sup - sup 3 tracks/neutron to within +- 15%. The detectors used in the second high-level run were gold foils (260 mg/cm sup 2 thick) for determination of the show neutron distribution. Previous experiments with 0.13 MeV, 2.5 MeV, 14 MeV and Po-Be neutrons have shown that the shape of the curve through a phantom obtained from these gold foils is the same as that given by either manganese foils or sodium samples despite the difference in resonance integrals. From the relaxation length of the neutron flux in the phantom, as measured by the track plates, the mean energy of the neutrons with energies greater than 0.5 MeV may be found by comparison with the relaxation lengths obtained by irradiation of the phantom with monoenergetic neutrons. The results of these experiments are given. Track plate results from the Vinca experiment are shown. It can be seen that the backscattered fast flux is about one-third of the incident fast flux and that the energy indicated by the shape of the curve is considerably lower than the energy of the direct neutrons. It seems possible that the high

  19. Neutron measurements with a tissue-equivalent phantom

    Energy Technology Data Exchange (ETDEWEB)

    Smith, J W [Health Physics Division, Atomic Energy Establishment, Harwell (United Kingdom)

    1962-03-01

    This Appendix 3E of the dosimetry experiment at the R-B reactor describes the apparatus used and presents the obtained results. The phantom used was a 1/4-inch thick polythene container, 60 cm high, of elliptical cross-section, with a major axis of 36 cm and a minor axis of 20 cm. This was filled with an approximately tissue-equivalent liquid. A light but rigid internal framework of Perspex supported a series of small detectors through the phantom. The detectors used in the first high-level run at Vinca, to measure flux above 0.5 MeV, were 0.5-cm wide track plates wrapped in cadmium foil. Each track plate was a sandwich of two Ilford El 50 - {mu} emulsions, with glass backing, separated by a 250-{mu} polythene radiator, and was oriented at an angle of 45 deg to the front surface of the phantom. Under these conditions the response is constant with neutron energy between 0.5 MeV and 8 MeV at 1.26 X 10{sup -3} tracks/neutron to within {+-} 15%. The detectors used in the second high-level run were gold foils (260 mg/cm{sup 2} thick) for determination of the show neutron distribution. Previous experiments with 0.13 MeV, 2.5 MeV, 14 MeV and Po-Be neutrons have shown that the shape of the curve through a phantom obtained from these gold foils is the same as that given by either manganese foils or sodium samples despite the difference in resonance integrals. From the relaxation length of the neutron flux in the phantom, as measured by the track plates, the mean energy of the neutrons with energies greater than 0.5 MeV may be found by comparison with the relaxation lengths obtained by irradiation of the phantom with monoenergetic neutrons. The results of these experiments are given. Track plate results from the Vinca experiment are shown. It can be seen that the backscattered fast flux is about one-third of the incident fast flux and that the energy indicated by the shape of the curve is considerably lower than the energy of the direct neutrons. It seems possible that the

  20. Is the dose equivalent index a quantity to be measured

    International Nuclear Information System (INIS)

    Wagner, S.R.

    1980-01-01

    The following modifying factors are briefly considered in relation to the ambiguities and limitations of the Dose Equivalent Index: 1) Variations with time or of the movement of the exposed person 2) Irradiation geometry 3) Effect of radiation energy 4) Instrument performance and calibration, and other operational quantities. (U.K.)

  1. The European Person Equivalent: Measuring the personal environmental space

    DEFF Research Database (Denmark)

    Hauschild, Michael Zwicky; Wenzel, Henrik

    2001-01-01

    The European person equivalent (PE) is a quantification of the environmental impact caused annually by the activities of an average European. It comprises contributions to all the major environmental impacts from global to local as well as our consumption of resources. Similarly, the targeted...... European person equivalent is a quantification of the average person’s environmental impact in a near future according to the current politically set environmental targets. In addition to expressing the current societal priorities in pollution reduction, the targeted PE expresses the environmental space...... available to all of us according to the current environmental policy. Both concepts were developed in the mid-nineties for use in life cycle impact assessment to help comparisons across different environmental impact categories. Since then they have shown their value as a pedagogic tool in the presentation...

  2. Acceleration Measurements Using Smartphone Sensors: Dealing with the Equivalence Principle

    OpenAIRE

    Monteiro, Martín; Cabeza, Cecilia; Martí, Arturo C.

    2014-01-01

    Acceleration sensors built into smartphones, i-pads or tablets can conveniently be used in the physics laboratory. By virtue of the equivalence principle, a sensor fixed in a non-inertial reference frame cannot discern between a gravitational field and an accelerated system. Accordingly, acceleration values read by these sensors must be corrected for the gravitational component. A physical pendulum was studied by way of example, and absolute acceleration and rotation angle values were derived...

  3. Teacher ratings of ODD symptoms: measurement equivalence across Malaysian Malay, Chinese and Indian children.

    Science.gov (United States)

    Gomez, Rapson

    2014-04-01

    The study examined the measurement equivalence for teacher ratings across Malaysian Malay, Chinese and Indian children. Malaysian teachers completed ratings of the ODD symptoms for 574 Malay, 247 Chinese and 98 Indian children. The results supported the equivalences for the configural, metric, and error variances models, and the equivalences for ODD latent variances and mean scores. Together, these findings suggest good support for measurement and structural equivalences of the ODD symptoms across these ethnic groups. The theoretical and clinical implications of the findings for cross-cultural equivalence of the ODD symptoms are discussed. Copyright © 2013 Elsevier B.V. All rights reserved.

  4. Effect of compression ratio, equivalence ratio and engine speed on the performance and emission characteristics of a spark ignition engine using hydrogen as a fuel

    Energy Technology Data Exchange (ETDEWEB)

    Sadiq Al-Baghdadi, M.A.R. [University of Babylon (Iraq). Dept. of Mechanical Engineering

    2004-12-01

    The present energy situation has stimulated active research interest in non-petroleum and non-polluting fuels, particularly for transportation, power generation, and agricultural sectors. Researchers have found that hydrogen presents the best and an unprecedented solution to the energy crises and pollution problems, due to its superior combustion qualities and availability. This paper discusses analytically and provides data on the effect of compression ratio, equivalence ratio and engine speed on the engine performance, emissions and pre-ignition limits of a spark ignition engine operating on hydrogen fuel. These data are important in order to understand the interaction between engine performance and emission parameters, which will help engine designers when designing for hydrogen. (author)

  5. Novel method for equivalent stiffness and Coulomb's damping ratio analyses of leaf spring

    International Nuclear Information System (INIS)

    Wen Jun, Wu; Yu, Xiang; Le Mei, Zhu; Li Jun, He

    2012-01-01

    The leaf spring is a representative type of laminated structure. Based on the linear theories of curve beams, the first derivatives of the leave's status vector of the leaf spring are provided. The first derivatives of the combination status-vector are obtained by properly dealing with the nonlinear interacted forces between adjacent leaves. Moreover, the precise integration technology and the transform matrix method are introduced to solve the equations. The force displacement curve of a leaf spring is then calculated separately by using the present method and the finite element software ANSYS. From the results, the precision and advantages of the present methods for analyzing the leaf spring are revealed. The Coulomb's damping ratio of the leaf spring is studied by using the present method

  6. Effects of language of assessment on the measurement of acculturation: measurement equivalence and cultural frame switching.

    Science.gov (United States)

    Schwartz, Seth J; Benet-Martínez, Verónica; Knight, George P; Unger, Jennifer B; Zamboanga, Byron L; Des Rosiers, Sabrina E; Stephens, Dionne P; Huang, Shi; Szapocznik, José

    2014-03-01

    The present study used a randomized design, with fully bilingual Hispanic participants from the Miami area, to investigate 2 sets of research questions. First, we sought to ascertain the extent to which measures of acculturation (Hispanic and U.S. practices, values, and identifications) satisfied criteria for linguistic measurement equivalence. Second, we sought to examine whether cultural frame switching would emerge--that is, whether latent acculturation mean scores for U.S. acculturation would be higher among participants randomized to complete measures in English and whether latent acculturation mean scores for Hispanic acculturation would be higher among participants randomized to complete measures in Spanish. A sample of 722 Hispanic students from a Hispanic-serving university participated in the study. Participants were first asked to complete translation tasks to verify that they were fully bilingual. Based on ratings from 2 independent coders, 574 participants (79.5% of the sample) qualified as fully bilingual and were randomized to complete the acculturation measures in either English or Spanish. Theoretically relevant criterion measures--self-esteem, depressive symptoms, and personal identity--were also administered in the randomized language. Measurement equivalence analyses indicated that all of the acculturation measures--Hispanic and U.S. practices, values, and identifications-met criteria for configural, weak/metric, strong/scalar, and convergent validity equivalence. These findings indicate that data generated using acculturation measures can, at least under some conditions, be combined or compared across languages of administration. Few latent mean differences emerged. These results are discussed in terms of the measurement of acculturation in linguistically diverse populations. 2014 APA

  7. An experimental and numerical analysis of the influence of the inlet temperature, equivalence ratio and compression ratio on the HCCI auto-ignition process of Primary Reference Fuels in an engine

    Energy Technology Data Exchange (ETDEWEB)

    Machrafi, Hatim [UPMC Universite Paris 06, LGPPTS, Ecole Nationale Superieure de Chimie de Paris, 11, rue de Pierre et Marie Curie, 75005 Paris (France); UPMC Universite Paris 06, Institut Jean Le Rond D' Alembert (France); Cavadiasa, Simeon [UPMC Universite Paris 06, Institut Jean Le Rond D' Alembert (France)

    2008-11-15

    In order to understand better the auto-ignition process in an HCCI engine, the influence of some important parameters on the auto-ignition is investigated. The inlet temperature, the equivalence ratio and the compression ratio were varied and their influence on the pressure, the heat release and the ignition delays were measured. The inlet temperature was changed from 25 to 70 C and the equivalence ratio from 0.18 to 0.41, while the compression ratio varied from 6 to 13.5. The fuels that were investigated were PRF40 and n-heptane. These three parameters appeared to decrease the ignition delays, with the inlet temperature having the least influence and the compression ratio the most. A previously experimentally validated reduced surrogate mechanism, for mixtures of n-heptane, iso-octane and toluene, has been used to explain observations of the auto-ignition process. The same kinetic mechanism is used to better understand the underlying chemical and physical phenomena that make the influence of a certain parameter change according to the operating conditions. This can be useful for the control of the auto-ignition process in an HCCI engine. (author)

  8. Blood pressure measurements in the ankle are not equivalent to ...

    African Journals Online (AJOL)

    Background. Blood pressure (BP) is often measured on the ankle in the emergency department (ED), but this has never been shown to be an acceptable alternative to measurements performed on the arm. Objective. To establish whether the differences between arm and ankle non-invasive BP measurements were clinically ...

  9. Influence of fuel type, dilution and equivalence ratio on the emission reduction from the auto-ignition in an Homogeneous Charge Compression Ignition engine

    Energy Technology Data Exchange (ETDEWEB)

    Machrafi, Hatim [UPMC Universite Paris 06, ENSCP, 11 rue de Pierre et Marie Curie, 75005 Paris (France); UPMC Universite Paris 06, Institut Jean Le Rond D' Alembert, 4 place Jussieu, 75252 Paris cedex 05 (France); Universite Libre de Bruxelles, TIPs - Fluid Physics, CP165/67, 50 Avenue F.D. Roosevelt, 1050 Brussels (Belgium); Cavadias, Simeon [UPMC Universite Paris 06, ENSCP, 11 rue de Pierre et Marie Curie, 75005 Paris (France); UPMC Universite Paris 06, Institut Jean Le Rond D' Alembert, 4 place Jussieu, 75252 Paris cedex 05 (France); Amouroux, Jacques [UPMC Universite Paris 06, ENSCP, 11 rue de Pierre et Marie Curie, 75005 Paris (France)

    2010-04-15

    One technology that seems to be promising for automobile pollution reduction is the Homogeneous Charge Compression Ignition (HCCI). This technology still faces auto-ignition and emission-control problems. This paper focuses on the emission problem, since it is incumbent to realize engines that pollute less. For this purpose, this paper presents results concerning the measurement of the emissions of CO, NO{sub x}, CO{sub 2}, O{sub 2} and hydrocarbons. HCCI conditions are used, with equivalence ratios between 0.26 and 0.54, inlet temperatures of 70 C and 120 C and compression ratios of 10.2 and 13.5, with different fuel types: gasoline, gasoline surrogate, diesel, diesel surrogate and mixtures of n-heptane/toluene. The effect of dilution is considered for gasoline, while the effect of the equivalence ratio is considered for all the fuels. No significant amount of NO{sub x} has been measured. It appeared that the CO, O{sub 2} and hydrocarbon emissions were reduced by decreasing the toluene content of the fuel and by decreasing the dilution. The opposite holds for CO{sub 2}. The reduction of the hydrocarbon emission appears to compete with the reduction of the CO{sub 2} emission. Diesel seemed to produce less CO and hydrocarbons than gasoline when auto-ignited. An example of emission reduction control is presented in this paper. (author)

  10. Measurement equivalence of patient safety climate in Chinese hospitals: can we compare across physicians and nurses?

    Science.gov (United States)

    Zhu, Junya

    2018-06-11

    Self-report instruments have been widely used to better understand variations in patient safety climate between physicians and nurses. Research is needed to determine whether differences in patient safety climate reflect true differences in the underlying concepts. This is known as measurement equivalence, which is a prerequisite for meaningful group comparisons. This study aims to examine the degree of measurement equivalence of the responses to a patient safety climate survey of Chinese hospitals and to demonstrate how the measurement equivalence method can be applied to self-report climate surveys for patient safety research. Using data from the Chinese Hospital Survey of Patient Safety Climate from six Chinese hospitals in 2011, we constructed two groups: physicians and nurses (346 per group). We used multiple-group confirmatory factor analyses to examine progressively more stringent restrictions for measurement equivalence. We identified weak factorial equivalence across the two groups. Strong factorial equivalence was found for Organizational Learning, Unit Management Support for Safety, Adequacy of Safety Arrangements, Institutional Commitment to Safety, Error Reporting and Teamwork. Strong factorial equivalence, however, was not found for Safety System, Communication and Peer Support and Staffing. Nevertheless, further analyses suggested that nonequivalence did not meaningfully affect the conclusions regarding physician-nurse differences in patient safety climate. Our results provide evidence of at least partial equivalence of the survey responses between nurses and physicians, supporting mean comparisons of its constructs between the two groups. The measurement equivalence approach is essential to ensure that conclusions about group differences are valid.

  11. Incorporating Measurement Non-Equivalence in a Cross-Study Latent Growth Curve Analysis.

    Science.gov (United States)

    Flora, David B; Curran, Patrick J; Hussong, Andrea M; Edwards, Michael C

    2008-10-01

    A large literature emphasizes the importance of testing for measurement equivalence in scales that may be used as observed variables in structural equation modeling applications. When the same construct is measured across more than one developmental period, as in a longitudinal study, it can be especially critical to establish measurement equivalence, or invariance, across the developmental periods. Similarly, when data from more than one study are combined into a single analysis, it is again important to assess measurement equivalence across the data sources. Yet, how to incorporate non-equivalence when it is discovered is not well described for applied researchers. Here, we present an item response theory approach that can be used to create scale scores from measures while explicitly accounting for non-equivalence. We demonstrate these methods in the context of a latent curve analysis in which data from two separate studies are combined to create a single longitudinal model spanning several developmental periods.

  12. Mathematical model to predict temperature profile and air–fuel equivalence ratio of a downdraft gasification process

    International Nuclear Information System (INIS)

    Jaojaruek, Kitipong

    2014-01-01

    Highlights: • A mathematical model based on finite computation analysis was developed. • Model covers all zones of gasification process which will be useful to improve gasifier design. • Model can predict temperature profile, feedstock consumption rate and reaction equivalent ratio (ϕ). • Model-predicted parameters fitted well with experimental values. - Abstract: A mathematical model for the entire length of a downdraft gasifier was developed using thermochemical principles to derive energy and mass conversion equations. Analysis of heat transfer (conduction, convection and radiation) and chemical kinetic technique were applied to predict the temperature profile, feedstock consumption rate (FCR) and reaction equivalence ratio (RER). The model will be useful for designing gasifiers, estimating output gas composition and gas production rate (GPR). Implicit finite difference method solved the equations on the considered reactor length (50 cm) and diameter (20 cm). Conversion criteria for calculation of temperature and feedstock consumption rate were 1 × 10 −6 °C and 1 × 10 −6 kg/h, respectively. Experimental validation showed that model outputs fitted well with experimental data. Maximum deviation between model and experimental data of temperature, FCR and RER were 52 °C at combustion temperature 663 °C, 0.7 kg/h at the rate 8.1 kg/h and 0.03 at the RER 0.42, respectively. Experimental uncertainty of temperature, FCR and RER were 24.4 °C, 0.71 kg/h and 0.04, respectively, on confidence level of 95%

  13. The Use Of Optical Properties Of Cr-39 In Alpha Particle Equivalent Dose Measurements

    International Nuclear Information System (INIS)

    Shnishin, K.A.

    2007-01-01

    In this work, optical properties of alpha irradiated Cr-39 were measured as a function of optical photon wavelength from 200-1100 nm. Optical energy gap and optical absorption at finite wavelength was also calculated and correlated to alpha fluence and dose equivalent. Alpha doses were calculated from the corresponding irradiation fluence and specific energy loss using TRIM computer program. It was found that, the optical absorption of unattached Cr-39 was varied with alpha fluence and corresponding equivalent doses. Also the optical energy gab was varied with fluence and dose equivalent of alpha particles. This work introduces a reasonably simple method for the Rn dose equivalent calculation by Cr-39 track

  14. Effect of Temperature, Pressure and Equivalence Ratio on Ignition Delay in Ignition Quality Tester (IQT): Diesel,n-Heptane, andiso-Octane Fuels under Low Temperature Conditions

    KAUST Repository

    Yang, Seung Yeon; Naser, Nimal; Chung, Suk-Ho; Cha, Junepyo

    2015-01-01

    -octane in relatively low temperature conditions to simulate unsteady spray ignition behavior. A KAUST Research ignition quality tester (KR-IQT) was utilized, which has a feature of varying temperature, pressure and equivalence ratio using a variable displacement fuel

  15. Cross-Ethnicity Measurement Equivalence of Family Coping for Breast Cancer Survivors

    Science.gov (United States)

    Lim, Jung-won; Townsend, Aloen

    2012-01-01

    Objective: The current study examines the equivalence of a measure of family coping, the Family Crisis Oriented Personal Evaluation scales (F-COPES), in Chinese American and Korean American breast cancer survivors (BCS). Methods: Factor structure and cross-ethnicity equivalence of the F-COPES were tested using structural equation modeling with 157…

  16. A Study on intelligent measurement of nuclear explosion equivalent in atmosphere

    International Nuclear Information System (INIS)

    Wang Desheng; Wu Xiaohong

    1999-01-01

    Measurement of nuclear explosion equivalent in atmosphere is an important subject for nuclear survey. Based on the relations between nuclear explosion equivalent and the minimum illuminance time of light radiation from nuclear explosion. The method of RC differential valley time detection and mean-time taking is presented the method, using a single-chip computer as a intelligent part, can realize intelligent measurement of minimum illuminance time with high reliability and low power consumption. This method provides a practical mean for quick, accurate and reliable measurement of nuclear explosion equivalent in atmosphere

  17. Measurement of ambient dose equivalent H*(10) and directional dose equivalent H'(0.07) with pocket sized survey meters

    International Nuclear Information System (INIS)

    Iwatschenko, Michael

    2008-01-01

    Full text: In many parts of the world, predominantly in Europe, small sized survey meters based on Geiger-Mueller or proportional counters are widely used for dose rate and dose equivalent rate measurements, while in other regions, especially in the U.S., ionisation chambers are preferred for this task. This paper tries to shed some light on the likely reasons for these two diverging instrumental inclinations. Their respective strengths and weaknesses is analyzed in respect to energy response, dose rate measuring range, size, weight and susceptibility to environmental influences. Furthermore the response and limitations regarding the measurement of pulsed radiation (medical X-ray and CT-devices, accelerators, non-destructive testing) is discussed. A newly developed pocket size instrument based on a pan-cake Geiger-Mueller tube is used as an example to explain the capability and flexibility of modern survey meters. The RadEye B20 is a compact multi-purpose dose rate meter and contamination meter for alpha, beta, gamma and X-ray radiation. By virtue of carefully designed multi-layer gamma energy filters, H*(10) (deep dose) or H'(0,07) (shallow dose) measurements from 17 - 1300 keV can be performed. The instrument can even be worn in a belt holster, so that the impact to the mobility of the user is minimized. For emergency response purposes alpha and beta contamination can be discriminated using another optional filter; a simple sample changer adapter can extend the scope of application. Immediate and reproducible counter measurements, e.g. of smear tests can be performed locally. (author)

  18. Guideline values for skin decontamination measures based on nuclidspecific dose equivalent rate factors

    International Nuclear Information System (INIS)

    Pfob, H.; Heinemann, G.

    1992-01-01

    Corresponding dose equivalent rate factors for various radionuclides are now available for determining the skin dose caused by skin contamination. These dose equivalent rate factors take into account all contributions from the types of radiation emitted. Any limits for skin decontamination measures are nowhere contained or determined yet. However, radiological protection does in practice require at least guideline values in order to prevent unsuitable or detrimental measures that can be noticed quite often. New calculations of dose equivalent rate factors for the skin now make the recommendation of guideline values possible. (author)

  19. Equity-regarding poverty measures: differences in needs and the role of equivalence scales

    OpenAIRE

    Udo Ebert

    2010-01-01

    The paper investigates the definition of equity-regarding poverty measures when there are different household types in the population. It demonstrates the implications of a between-type regressive transfer principle for poverty measures, for the choice of poverty lines, and for the measurement of living standard. The role of equivalence scales, which are popular in empirical work on poverty measurement, is clarified.

  20. Mechanical properties investigation on single-wall ZrO2 nanotubes: A finite element method with equivalent Poisson's ratio for chemical bonds

    Science.gov (United States)

    Yang, Xiao; Li, Huijian; Hu, Minzheng; Liu, Zeliang; Wärnå, John; Cao, Yuying; Ahuja, Rajeev; Luo, Wei

    2018-04-01

    A method to obtain the equivalent Poisson's ratio in chemical bonds as classical beams with finite element method was proposed from experimental data. The UFF (Universal Force Field) method was employed to calculate the elastic force constants of Zrsbnd O bonds. By applying the equivalent Poisson's ratio, the mechanical properties of single-wall ZrNTs (ZrO2 nanotubes) were investigated by finite element analysis. The nanotubes' Young's modulus (Y), Poisson's ratio (ν) of ZrNTs as function of diameters, length and chirality have been discussed, respectively. We found that the Young's modulus of single-wall ZrNTs is calculated to be between 350 and 420 GPa.

  1. Cross-Ethnic Measurement Equivalence of the RCMAS in Latino and Caucasian Youth with Anxiety Disorders

    OpenAIRE

    Pina, Armando A.; Little, Michelle; Knight, George P.; Silverman, Wendy K.

    2009-01-01

    The measurement equivalence of the Revised Children's Manifest Anxiety Scale (RCMAS) was examined in a sample of 667 Caucasian and Latino youth referred to an anxiety disorders specialty clinic. Findings supported the factorial invariance of the Physiological Anxiety, Worry/Oversensitivity, and Social Concerns/Concentration subscales as well as the construct validity equivalence of the Total Anxiety scale. These findings suggest that the RCMAS can be used with Latino youth in cross-ethnic res...

  2. Radon and daughters in cigarette smoke measured with SSNTD and corresponding committed equivalent dose to respiratory tract

    International Nuclear Information System (INIS)

    Misdaq, M.A.; Flata, K.

    2003-01-01

    Uranium ( 238 U) and Thorium ( 232 Th) contents were measured inside various tobacco samples by using a method based on determining detection efficiencies of the CR-39 and LR-115 II solid state nuclear track detector (SSNTD) for the emitted alpha particles. Alpha and beta activities per unit volume, due to radon ( 222 Rn), thoron ( 220 Rn) and their decay products, were evaluated inside cigarette smokes of tobacco samples studied. Annual committed equivalent doses due to short-lived radon decay products from the inhalation of various cigarette smokes were determined in the thoracic and extrathoracic regions of the respiratory tract. Three types of cigarettes made in Morocco of black tobacco show higher annual committed equivalent doses in the extrathoracic and thoracic regions of the respiratory tract than the other studied cigarettes (except one type of cigarettes made in France of yellow tobacco); their corresponding annual committed equivalent dose ratios are larger than 1.8. Measured annual committed equivalent doses ranged from 1.8x10 -9 to 1.10x10 -3 Sv yr -1 in the extrathoracic region and from 1.3x10 -10 to 7.6x10 -6 Sv yr -1 in the thoracic region of the respiratory tract for a smoker consuming 20 cigarettes a day

  3. Measurement of californium-252 gamma photons depth dose distribution in tissue equivalent material. Vol. 4

    Energy Technology Data Exchange (ETDEWEB)

    Fadel, M A; El-Fiki, M A; Eissa, H M; Abdel-Hafez, A; Naguib, S H [National Institute of Standards, Cairo (Egypt)

    1996-03-01

    Phantom of tissue equivalent material with and without bone was used measuring depth dose distribution of gamma-rays from californium-252 source. The source was positioned at center of perspex walled phantom. Depth dose measurements were recorded for X, Y and Z planes at different distances from source. TLD 700 was used for measuring the dose distribution. Results indicate that implantation of bone in tissue equivalent medium cause changes in the gamma depth dose distribution which varies according to variation in bone geometry. 9 figs.

  4. Tissue equivalent detector measurements on Mir space station. Comparison with other data

    Energy Technology Data Exchange (ETDEWEB)

    Bottollier-Depois, J.F. [CEA Centre d`Etudes de Fontenay-aux-Roses, 92 (France). Dept. de Protection de la Sante de l`Homme et de Dosimetrie; Siegrist, M. [Centre National d`Etudes Spatiales (CNES), 31 - Toulouse (France); Duvivier, E.; Almarcha, B. [STEEL Technologies, Mazeres sur Salat (France); Dachev, T.P.; Semkova, J.V. [Bulgarian Academy of Sciences, Sofia (Bulgaria). Central Lab. of Solar Energy and New Energy Sources; Petrov, V.M.; Bengin, V.; Koslova, S.B. [Institute of Biomedical Problems, Moscow (Russian Federation)

    1995-12-31

    The measurement of the dose received by the cosmonauts, due to cosmic radiations, during a space mission is an important parameter to estimate the radiological risk. Tissue equivalent measurements of radiation environment inside the MIR space station were performed continuously since July 1992. Interesting results about radiation measurements show (a) the South Atlantic Anomaly (SAA) crossing, (c) the increase of radiation near the poles and (d) the effects of solar eruptions. These data are compared with solid state detector (SSD) and other tissue equivalent proportional counter (TEPC) results. (authors). 4 refs., 7 figs.

  5. Tissue equivalent detector measurements on Mir space station. Comparison with other data

    International Nuclear Information System (INIS)

    Bottollier-Depois, J.F.; Duvivier, E.; Almarcha, B.; Dachev, T.P.; Semkova, J.V.

    1995-01-01

    The measurement of the dose received by the cosmonauts, due to cosmic radiations, during a space mission is an important parameter to estimate the radiological risk. Tissue equivalent measurements of radiation environment inside the MIR space station were performed continuously since July 1992. Interesting results about radiation measurements show (a) the South Atlantic Anomaly (SAA) crossing, (c) the increase of radiation near the poles and (d) the effects of solar eruptions. These data are compared with solid state detector (SSD) and other tissue equivalent proportional counter (TEPC) results. (authors). 4 refs., 7 figs

  6. New equivalent-electrical circuit model and a practical measurement method for human body impedance.

    Science.gov (United States)

    Chinen, Koyu; Kinjo, Ichiko; Zamami, Aki; Irei, Kotoyo; Nagayama, Kanako

    2015-01-01

    Human body impedance analysis is an effective tool to extract electrical information from tissues in the human body. This paper presents a new measurement method of impedance using armpit electrode and a new equivalent circuit model for the human body. The lowest impedance was measured by using an LCR meter and six electrodes including armpit electrodes. The electrical equivalent circuit model for the cell consists of resistance R and capacitance C. The R represents electrical resistance of the liquid of the inside and outside of the cell, and the C represents high frequency conductance of the cell membrane. We propose an equivalent circuit model which consists of five parallel high frequency-passing CR circuits. The proposed equivalent circuit represents alpha distribution in the impedance measured at a lower frequency range due to ion current of the outside of the cell, and beta distribution at a high frequency range due to the cell membrane and the liquid inside cell. The calculated values by using the proposed equivalent circuit model were consistent with the measured values for the human body impedance.

  7. Term-equivalent functional brain maturational measures predict neurodevelopmental outcomes in premature infants.

    Science.gov (United States)

    El Ters, Nathalie M; Vesoulis, Zachary A; Liao, Steve M; Smyser, Christopher D; Mathur, Amit M

    2018-04-01

    Term equivalent age (TEA) brain MRI identifies preterm infants at risk for adverse neurodevelopmental outcomes. But some infants may experience neurodevelopmental impairments even in the absence of neuroimaging abnormalities. Evaluate the association of TEA amplitude-integrated EEG (aEEG) measures with neurodevelopmental outcomes at 24-36 months corrected age. We performed aEEG recordings and brain MRI at TEA (mean post-menstrual age of 39 (±2) weeks in a cohort of 60 preterm infants born at a mean gestational age of 26 (±2) weeks. Forty-four infants underwent Bayley Scales of Infant Development, 3rd Edition (BSID-III) testing at 24-36 months corrected age. Developmental delay was defined by a score greater than one standard deviation below the mean (neurodevelopmental outcomes was assessed using odds ratio, then adjusted for confounding variables using logistic regression. Infants with developmental delay in any domain had significantly lower values of SEF 90 . Absent cyclicity was more prevalent in infants with cognitive and motor delay. Both left and right SEF 90  neurodevelopmental outcomes. Therefore, a larger study is needed to validate these results in premature infants at low and high risk of brain injury. Copyright © 2018. Published by Elsevier B.V.

  8. Measurement of cardiopulmonary performance during acute exposure to a 2440-m equivalent atmosphere

    Science.gov (United States)

    Levitan, B. M.; Bungo, M. W.

    1982-01-01

    Each of 20 subjects (ranging in age from 18 to 38 years, 15 being male, five female) was given two Bruce Protocol symptom-limited maximum treadmill stress tests, breathing sea-level compressed air (20.9% O2) for one test and a 2440-m equivalent (15.5% O2) for the other. A significant difference was found to exist between measured VO2 max (p less than 0.0002) and exercise time (p less than 0.0004) for the two conditions. No significant differences were observed in heart rate or the recovery time to a respiratory quotient of less than 1. Hemoglobin saturation, as measured by an ear oximeter, averaged 95% for sea-level and 91% for the 2440-m equivalent gases. These results support a 2440-m equivalent contingency atmosphere in the Space Shuttle prior to donning a low-pressure suit for the purpose reducing nitrogen washout times.

  9. Measurements of K/Π ratio in cosmic radiation

    International Nuclear Information System (INIS)

    Mahon, J.R.P.

    1986-01-01

    Measurements of k/Π ratio in cosmic radiation by its half lives and its fluxes, were carried out. The kaon flux was obtained using the Cherenkov detector, and for pion flux scintillation detectors were used. The final results of K/Π ratio ∼ 0.2 was obtained. (M.C.K.) [pt

  10. Influence of ethanol admixture on the determination of equivalence ratios in DISI engines by laser-induced fluorescence.

    Science.gov (United States)

    Storch, Michael; Lind, Susanne; Will, Stefan; Zigan, Lars

    2016-10-20

    In this work, the planar laser-induced fluorescence of a fuel tracer is applied for the analysis of mixture formation for various ethanol/iso-octane blends in a direct-injection spark-ignition (DISI) engine. The tracer triethylamine (TEA) was added to pure iso-octane and ethanol as well as to their blends E20 and E85 for the measurement of the fuel/air ratio. In general, ethanol blending strongly affects the mixture formation process, which is caused by specific physical fuel properties influencing the evaporation process of ethanol in comparison to iso-octane. As interactions of the fuel and tracer fluorescence appear possible, TEA fluorescence was studied for different fuel blends in a cuvette, in a calibration cell under constant conditions, and in an optically accessible internal combustion engine at late injection timing. It was found that ethanol blending strongly affects the fluorescence intensity of TEA in the liquid phase, which can be explained by the interaction of the tracer and ethanol molecules. However, in the gas phase a quantification of the fuel/air ratio is possible for different ethanol fuel blends, which is demonstrated in a DISI engine. Under stratified charge conditions the engine results showed a significant impact of a high amount of ethanol on the mixture formation process, leading to a leaner mixture in comparison to iso-octane.

  11. Effect of cigarette smoke on the measured equivalent volume activity of 222Rn in air

    International Nuclear Information System (INIS)

    Tuckova, S.; Tykva, R.

    1994-01-01

    The effect of cigarette smoke in air on the increase of the measured equivalent volume activity of 222 Rn is demonstrated. After introduction of the smoke from one cigarette into 1 m 3 of air, this value increased up to ten times as shown be the method of sucking air through a filter. (author) 5 refs.; 1 fig

  12. Measurement Equivalence across Racial/Ethnic Groups of the Mood and Feelings Questionnaire for Childhood Depression

    Science.gov (United States)

    Banh, My K.; Crane, Paul K.; Rhew, Isaac; Gudmundsen, Gretchen; Stoep, Ann Vander; Lyon, Aaron; McCauley, Elizabeth

    2012-01-01

    As research continues to document differences in the prevalence of mental health problems such as depression across racial/ethnic groups, the issue of measurement equivalence becomes increasingly important to address. The Mood and Feelings Questionnaire (MFQ) is a widely used screening tool for child and adolescent depression. This study applied a…

  13. Does the EDI Equivalently Measure Facets of School Readiness for Aboriginal and Non-Aboriginal Children?

    Science.gov (United States)

    Muhajarine, Nazeem; Puchala, Chassidy; Janus, Magdalena

    2011-01-01

    The aim of the current paper was to examine the equivalence of the Early Development Instrument (EDI), a teacher rating measure of school readiness, for Aboriginal and non-Aboriginal children. The current study used an approach, which analyzes the structure and properties of the EDI at the subdomain level. Similar subdomain score distributions…

  14. Dispositional resistance to change: Measurement equivalence and the link to personal values across 17 nations

    Czech Academy of Sciences Publication Activity Database

    Oreg, S.; Bayazit, M.; Vakola, M.; Arciniega, L.; Armenakis, A.; Barkauskiene, R.; Bozionelos, N.; Ferič, I.; Fujimoto, Y.; Gonzáles, L.; Han, J.; Hetland, H.; Hřebíčková, Martina; Jimmieson, N.; Kordačová, J.; Kotrla Topič, M.; Mitsuhashi, H.; Mlacić, B.; Ohly, S.; Saksvik, I.; Saksvik, P.O.; van Dam, K.

    2008-01-01

    Roč. 93, č. 4 (2008), s. 935-944 ISSN 0021-9010 R&D Projects: GA AV ČR IAA700250702 Institutional research plan: CEZ:AV0Z70250504 Keywords : resistance to change * personal values * measurement equivalence Subject RIV: AN - Psychology Impact factor: 3.769, year: 2008

  15. Path integral measure and the fermion-boson equivalence in the Schwinger model

    International Nuclear Information System (INIS)

    Maiella, G.

    1980-02-01

    I perform a change of field variables in the Schwinger model using the non-invariance of path integral measure under γ 5 transformations. The known equivalence of the model with a bosonic field theory and the Kogut-Susskind dipole mechanism is then derived. (author)

  16. Fast fission ratio and relative conversion ratio measurements in gadolinium poisoned water moderated UO2 lattices

    International Nuclear Information System (INIS)

    Murphy, M.F.

    1984-01-01

    A programme of criticality experiments has been carried out for BNFL by the Battelle reactor facility at Pacific Northwest Laboratories in Washington State, USA. A series of water moderated lattices of 4.3% enriched, 12.7 mm diameter, UO 2 fuel rods was studied, the fuel pitch was varied and the effects of gadolinium poison were measured. This report deals with the measurement of Fast Fission Ratios and Relative Conversion Ratios at the centre of five of the critical lattices. The Fast Fission Ratio (FFR) is defined here as the ratio of the fission rate per atom of U238, to the fission rate per atom of U235. The Relative Conversion Ratio (RCR) is defined as the ratio of the capture rate per ,atom of U238, to the fission rate per atom of U235, in the reactor fuel, relative to the corresponding ratio in a well thermalised neutron spectrum. A major aspect of these measurements was that the packs of foils were prepared at AEEW Winfrith, despatched to the USA for irradiation and returned to Winfrith for counting. This resulted in a considerable logistics problem but by good planning and the co-operation and diligence of all concerned this problem was overcome. However, the long distance involved inevitably meant that samples were not available for measurement until about 28 hours after the irradiation. It was therefore necessary to modify the techniques that are normally used in the Reactor Physics Division Counting Laboratory, where samples are normally available about two hours after shut-down. The techniques used and the results obtained are given below

  17. Lead Equivalent Thickness Measurement for Mixed Compositions of Barium Plaster Block

    International Nuclear Information System (INIS)

    Norriza Mohd Isa; Muhammad Jamal Muhammad Isa; Nur Shahriza Zainuddin; Mohd Khairusalih Md Zin; Shahrul Azlan Azizan

    2016-01-01

    Measurement of lead equivalent thickness for ionizing radiation exposure room wall shall be performed as stated in Malaysian Standard MS 838. A few numbers of sample blocks with different mixture of barium plaster compositions based and varies certain thickness as a shielding material for exposure room wall belong to a local company were tested by using Cs-137, Co-60 and Am-241 with different activities . Radiations passed through the samples were detected with calibrated survey meter. The distance between radiation source and the detector is about 40 cm. Lead uniformity test on the samples was also determined at three labeled points on the samples. Lead equivalent thicknesses for the samples were evaluated based on a calibration graph that was plotted with lead sheets and with the radiation sources. Results shown that lead equivalent thickness for the samples with same actual physical thickness represent different values for different sources. (author)

  18. Analyzing the Measurement Equivalence of a Translated Test in a Statewide Assessment Program

    Directory of Open Access Journals (Sweden)

    Jorge Carvajal-Espinoza

    2016-09-01

    Full Text Available When tests are translated into one or more languages, the question of the equivalence of items across language forms arises. This equivalence can be assessed at the scale level by means of a multiple group confirmatory factor analysis (CFA in the context of structural equation modeling. This study examined the measurement equivalence of a Spanish translated version of a statewide Mathematics test originally constructed in English by using a multi-group CFA approach. The study used samples of native speakers of the target language of the translation taking the test in both the source and target language, specifically Hispanics taking the test in English and Spanish. Test items were grouped in twelve facet-representative parcels. The parceling was accomplished by grouping items that corresponded to similar content and computing an average for each parcel. Four models were fitted to examine the equivalence of the test across groups. The multi-group CFA fixed factor loadings across groups and results supported the equivalence of the two language versions (English and Spanish of the test. The statistical techniques implemented in this study can also be used to address the performance on a test based on dichotomous or dichotomized variables such as gender, socioeconomic status, geographic location and other variables of interest.

  19. Absorbed dose measurement by using tissue equivalent ionization chamber (pair ionization chamber) in the Yayoi reactor

    International Nuclear Information System (INIS)

    Sasuga, N.; Okamura, K.; Terakado, T.; Mabuchi, Y.; Nakagawa, T.; Sukegawa, Toshio; Aizawa, C.; Saito, I.; Oka, Yoshiaki

    1998-01-01

    Each dose rate of neutron and gamma ray in the thermal column of the Yayoi reactor, in which an epithermal neutron field will be used for the boron neutron capture therapy, was measured by using a tissue equivalent ionization chamber and a graphite chamber. The tissue equivalent ionization chamber has some response to both neutron and gamma ray, but the graphite chamber has a few response to the neutron, so called pair ionization chamber method. The epithermal neutron fluxes of the thermal column were calculated by ANISN (one dimensional neutron-gamma transport code). A measured value for gamma dose rate by the pair ionization chamber agrees relevantly with a calculated result. For neutron dose rate, however, the measured value was too much small in comparison with the calculated result. The discrepancy between the measured value and the calculated result for neutron dose rate is discussed in detail in the report. (M. Suetake)

  20. Business sustainability performance measurement: Eco-ratio analysis

    Directory of Open Access Journals (Sweden)

    Collins C. Ngwakwe

    2016-12-01

    Full Text Available Eco-aware customers and stakeholders are demanding for a measurement that links environmental performance with other business operations. To bridge this seemingly measurement gap, this paper suggests ‘Eco-Ratio Analysis’ and proposes an approach for conducting eco-ratio analysis. It is argued that since accounting ratios function as a tool for evaluating corporate financial viability by management and investors, eco-ratio analysis should be brought to the fore to provide a succinct measurement about the linkage between environmental performance and conventional business performance. It is hoped that this suggestion will usher in a nuance debate and approach in the teaching, research and practice of environmental management and sustainability accounting

  1. Nondestructive measurement of the grid ratio using a single image

    International Nuclear Information System (INIS)

    Pasciak, A. S.; Jones, A. Kyle

    2009-01-01

    The antiscatter grid is an essential part of modern radiographic systems. Since the introduction of the antiscatter grid, however, there have been few methods proposed for acceptance testing and verification of manufacturer-supplied grid specifications. The grid ratio (r) is an important parameter describing the antiscatter grid because it affects many other grid quality metrics, such as the contrast improvement ratio (K), primary transmission (T p ), and scatter transmission (T s ). Also, the grid ratio in large part determines the primary clinical use of the grid. To this end, the authors present a technique for the nondestructive measurement of the grid ratio of antiscatter grids. They derived an equation that can be used to calculate the grid ratio from a single off-focus flat field image by exploiting the relationship between grid cutoff and off-focus distance. The calculation can be performed by hand or with included analysis software. They calculated the grid ratios of several different grids throughout the institution, and afterward they destructively measured the grid ratio of a nominal r8 grid previously evaluated with the method. They also studied the sensitivity of the method to technical factors and choice of parameters. With one exception, the results for the grids found in the institution were in agreement with the manufacturer's specifications and international standards. The nondestructive evaluation of the r8 grid indicated a ratio of 7.3, while the destructive measurement indicated a ratio of 7.53±0.28. Repeated evaluations of the same grid yielded consistent results. The technique provides the medical physicist with a new tool for quantitative evaluation of the grid ratio, an important grid performance criterion. The method is robust and repeatable when appropriate choices of technical factors and other parameters are made.

  2. Americium-241 use of measurement lead equivalent thickness for medical x-ray room: A review

    International Nuclear Information System (INIS)

    Mohd Khalid Matori; Husaini Saleh; Abd Aziz Mhd Ramli; Muhammad Jamal Md Isa; Mohd Firdaus Abd Rahman; Zainal Jamaluddin

    2010-01-01

    Lead equivalent thickness measurement of a shielding material in diagnostic radiology is very important to ensure that requirements for the purpose of radiation protection of patients, employees and the public are met. The Malaysian Ministry of Health (MOH) has established that the irradiation room must have sufficient shielding thickness, for example for general radiography it must be at least equal to 2.0 mm of Pb, for panoramic dental radiography at least equal to 1.5 mm of Pb and for mammography should be a minimum of 1.0 mm of Pb. This paper presents a technique using americium-241 source to test and verify the integrity of the shielding thickness in term of lead equivalent for X-ray room at health centres. Results of measurement of 30 irradiation rooms conducted from 2009 to mid 2010 were analyzed for this presentation. Technical comparison of the attenuation of gamma rays from Am-241 source through the walls of the irradiation room and pieces of lead were used to assess the lead equivalent thickness of the walls. Results showed that 96.7 % of the irradiation rooms tested meet the requirements of the Ministry of Health and is suitable for the installation of the intended diagnostic X-ray apparatus. Some specific positions such as door knobs and locks, electrical plug sockets were identified with potential to not met the required lead equivalent thickness hence may contribute to higher radiation exposure to workers and the public. (author)

  3. Snowpack snow water equivalent measurement using the attenuation of cosmic gamma radiation

    International Nuclear Information System (INIS)

    Osterhuber, R.; Condreva, K.

    1998-01-01

    Incoming, background cosmic radiation constantly fluxes through the earth's atmosphere. The high energy gamma portion of this radiation penetrates many terrestrial objects, including the winter snowpack. The attenuation of this radiation is exponentially related to the mass of the medium through which it penetrates. For the past three winters, a device measuring cosmic gamma radiation--and its attenuation through snow--has been installed at the Central Sierra Snow Laboratory, near Donner Pass, California. This gamma sensor, measuring energy levels between 5 and 15 MeV, has proved to be an accurate, reliable, non-invasive, non-mechanical instrument with which to measure the total snow water equivalent of a snowpack. This paper analyzes three winters' worth of data and discusses the physics and practical application of the sensor for the collection of snow water equivalent data from a remote location

  4. Precise and accurate isotope ratio measurements by ICP-MS.

    Science.gov (United States)

    Becker, J S; Dietze, H J

    2000-09-01

    The precise and accurate determination of isotope ratios by inductively coupled plasma mass spectrometry (ICP-MS) and laser ablation ICP-MS (LA-ICP-MS) is important for quite different application fields (e.g. for isotope ratio measurements of stable isotopes in nature, especially for the investigation of isotope variation in nature or age dating, for determining isotope ratios of radiogenic elements in the nuclear industry, quality assurance of fuel material, for reprocessing plants, nuclear material accounting and radioactive waste control, for tracer experiments using stable isotopes or long-lived radionuclides in biological or medical studies). Thermal ionization mass spectrometry (TIMS), which used to be the dominant analytical technique for precise isotope ratio measurements, is being increasingly replaced for isotope ratio measurements by ICP-MS due to its excellent sensitivity, precision and good accuracy. Instrumental progress in ICP-MS was achieved by the introduction of the collision cell interface in order to dissociate many disturbing argon-based molecular ions, thermalize the ions and neutralize the disturbing argon ions of plasma gas (Ar+). The application of the collision cell in ICP-QMS results in a higher ion transmission, improved sensitivity and better precision of isotope ratio measurements compared to quadrupole ICP-MS without the collision cell [e.g., for 235U/238U approximately 1 (10 microg x L(-1) uranium) 0.07% relative standard deviation (RSD) vs. 0.2% RSD in short-term measurements (n = 5)]. A significant instrumental improvement for ICP-MS is the multicollector device (MC-ICP-MS) in order to obtain a better precision of isotope ratio measurements (with a precision of up to 0.002%, RSD). CE- and HPLC-ICP-MS are used for the separation of isobaric interferences of long-lived radionuclides and stable isotopes by determination of spallation nuclide abundances in an irradiated tantalum target.

  5. Analytical Validation of Accelerator Mass Spectrometry for Pharmaceutical Development: the Measurement of Carbon-14 Isotope Ratio

    International Nuclear Information System (INIS)

    Keck, B.D.; Ognibene, T.; Vogel, J.S.

    2010-01-01

    Accelerator mass spectrometry (AMS) is an isotope based measurement technology that utilizes carbon-14 labeled compounds in the pharmaceutical development process to measure compounds at very low concentrations, empowers microdosing as an investigational tool, and extends the utility of 14 C labeled compounds to dramatically lower levels. It is a form of isotope ratio mass spectrometry that can provide either measurements of total compound equivalents or, when coupled to separation technology such as chromatography, quantitation of specific compounds. The properties of AMS as a measurement technique are investigated here, and the parameters of method validation are shown. AMS, independent of any separation technique to which it may be coupled, is shown to be accurate, linear, precise, and robust. As the sensitivity and universality of AMS is constantly being explored and expanded, this work underpins many areas of pharmaceutical development including drug metabolism as well as absorption, distribution and excretion of pharmaceutical compounds as a fundamental step in drug development. The validation parameters for pharmaceutical analyses were examined for the accelerator mass spectrometry measurement of 14 C/C ratio, independent of chemical separation procedures. The isotope ratio measurement was specific (owing to the 14 C label), stable across samples storage conditions for at least one year, linear over 4 orders of magnitude with an analytical range from one tenth Modern to at least 2000 Modern (instrument specific). Further, accuracy was excellent between 1 and 3 percent while precision expressed as coefficient of variation is between 1 and 6% determined primarily by radiocarbon content and the time spent analyzing a sample. Sensitivity, expressed as LOD and LLOQ was 1 and 10 attomoles of carbon-14 (which can be expressed as compound equivalents) and for a typical small molecule labeled at 10% incorporated with 14 C corresponds to 30 fg equivalents. AMS

  6. Analytical Validation of Accelerator Mass Spectrometry for Pharmaceutical Development: the Measurement of Carbon-14 Isotope Ratio.

    Energy Technology Data Exchange (ETDEWEB)

    Keck, B D; Ognibene, T; Vogel, J S

    2010-02-05

    Accelerator mass spectrometry (AMS) is an isotope based measurement technology that utilizes carbon-14 labeled compounds in the pharmaceutical development process to measure compounds at very low concentrations, empowers microdosing as an investigational tool, and extends the utility of {sup 14}C labeled compounds to dramatically lower levels. It is a form of isotope ratio mass spectrometry that can provide either measurements of total compound equivalents or, when coupled to separation technology such as chromatography, quantitation of specific compounds. The properties of AMS as a measurement technique are investigated here, and the parameters of method validation are shown. AMS, independent of any separation technique to which it may be coupled, is shown to be accurate, linear, precise, and robust. As the sensitivity and universality of AMS is constantly being explored and expanded, this work underpins many areas of pharmaceutical development including drug metabolism as well as absorption, distribution and excretion of pharmaceutical compounds as a fundamental step in drug development. The validation parameters for pharmaceutical analyses were examined for the accelerator mass spectrometry measurement of {sup 14}C/C ratio, independent of chemical separation procedures. The isotope ratio measurement was specific (owing to the {sup 14}C label), stable across samples storage conditions for at least one year, linear over 4 orders of magnitude with an analytical range from one tenth Modern to at least 2000 Modern (instrument specific). Further, accuracy was excellent between 1 and 3 percent while precision expressed as coefficient of variation is between 1 and 6% determined primarily by radiocarbon content and the time spent analyzing a sample. Sensitivity, expressed as LOD and LLOQ was 1 and 10 attomoles of carbon-14 (which can be expressed as compound equivalents) and for a typical small molecule labeled at 10% incorporated with {sup 14}C corresponds to 30 fg

  7. Measurement of the temperature coefficient of ratio transformers

    Science.gov (United States)

    Briggs, Matthew E.; Gammon, Robert W.; Shaumeyer, J. N.

    1993-01-01

    We have measured the temperature coefficient of the output of several ratio transformers at ratios near 0.500,000 using an ac bridge and a dual-phase, lock-in amplifier. The two orthogonal output components were each resolved to +/- ppb of the bridge drive signal. The results for three commercial ratio transformers between 20 and 50 C range from 0.5 to 100 ppb/K for the signal component in phase with the bridge drive, and from 4 to 300 ppb/K for the quadrature component.

  8. Measurement of absorbed dose with a bone-equivalent extrapolation chamber

    International Nuclear Information System (INIS)

    DeBlois, Francois; Abdel-Rahman, Wamied; Seuntjens, Jan P.; Podgorsak, Ervin B.

    2002-01-01

    A hybrid phantom-embedded extrapolation chamber (PEEC) made of Solid Water trade mark sign and bone-equivalent material was used for determining absorbed dose in a bone-equivalent phantom irradiated with clinical radiation beams (cobalt-60 gamma rays; 6 and 18 MV x rays; and 9 and 15 MeV electrons). The dose was determined with the Spencer-Attix cavity theory, using ionization gradient measurements and an indirect determination of the chamber air-mass through measurements of chamber capacitance. The collected charge was corrected for ionic recombination and diffusion in the chamber air volume following the standard two-voltage technique. Due to the hybrid chamber design, correction factors accounting for scatter deficit and electrode composition were determined and applied in the dose equation to obtain absorbed dose in bone for the equivalent homogeneous bone phantom. Correction factors for graphite electrodes were calculated with Monte Carlo techniques and the calculated results were verified through relative air cavity dose measurements for three different polarizing electrode materials: graphite, steel, and brass in conjunction with a graphite collecting electrode. Scatter deficit, due mainly to loss of lateral scatter in the hybrid chamber, reduces the dose to the air cavity in the hybrid PEEC in comparison with full bone PEEC by 0.7% to ∼2% depending on beam quality and energy. In megavoltage photon and electron beams, graphite electrodes do not affect the dose measurement in the Solid Water trade mark sign PEEC but decrease the cavity dose by up to 5% in the bone-equivalent PEEC even for very thin graphite electrodes (<0.0025 cm). In conjunction with appropriate correction factors determined with Monte Carlo techniques, the uncalibrated hybrid PEEC can be used for measuring absorbed dose in bone material to within 2% for high-energy photon and electron beams

  9. Measurement Equivalence of the Empowerment Scale for White and Black Persons with Severe Mental Illness

    Science.gov (United States)

    Morris, Scott B.; Huang, Jialin; Zhao, Lei; Sergent, Jessica D.; Neuhengen, Jonas

    2014-01-01

    Objective The current study examined the measurement equivalence on a measure of personal empowerment for African American and White consumers of mental health services. Methods Confirmatory Factor Analysis was used to assess measurement equivalences of the 28-item Empowerment Scale (Rogers, Chamberlin, Ellison & Crean, 1997), using data from 1,035 White and 301 African American persons with severe mental illness. Results Metric invariance of the Empowerment Scale was supported, in that the factor structure and loadings were equivalent across groups. Scalar invariance was violated on three items; however, the impact of these items on scale scores was quite small. Finally, subscales of empowerment tended to be more highly inter-correlated for African American than for White respondents. Conclusions and Implications for Practice Results generally support the use of Empowerment Scale for ethnic group comparisons. However, subtle differences in the psychometric properties of this measure suggest that African Americans and White individuals may conceptualize the construct of empowerment in different ways. Specifically, African American respondents had a lower threshold for endorsing some items on the self-esteem and powerlessness dimensions. Further, White respondents viewed the three dimensions of empowerment (self-esteem, powerlessness and activism) as more distinct, whereas these three traits were more strongly interrelated for African Americans. PMID:24884300

  10. Measurement equivalence of the newly developed Quality of Life in Childhood Epilepsy Questionnaire (QOLCE-55).

    Science.gov (United States)

    Ferro, Mark A; Goodwin, Shane W; Sabaz, Mark; Speechley, Kathy N

    2016-03-01

    The aim of this study was to examine measurement equivalence of the newly developed Quality of Life in Childhood Epilepsy Questionnaire (QOLCE-55) across age, sex, and time in a representative sample of children with newly diagnosed epilepsy. Data come from 373 children enrolled in the Health-related Quality of Life in Children with Epilepsy Study (HERQULES), a multisite prospective cohort study. Measurement equivalence was examined using a multiple-group confirmatory factor analysis framework, whereby increasingly stringent parameter constraints are imposed on the model. Comparison groups were stratified based on age (4-7 years vs. 8-12 years), sex (male vs. female), and time (measurement of health-related quality of life at diagnosis vs. 24 months later). The QOLCE-55 demonstrated measurement equivalence at the level of strict invariance for each model tested--age: χ(2) (3,123) = 4,097.3, p QOLCE-55 are perceived similarly among groups stratified by age, sex, and time and provide further evidence supporting the validity of the scale in children with epilepsy. Health professionals and researchers should be confident that group comparisons made using the QOLCE-55 are unbiased and that any group differences detected are meaningful; that is, not related to differences in the interpretation of items by informants. Future research replicating these findings is encouraged. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.

  11. Toxic Combustion Product Yields as a Function of Equivalence Ratio and Flame Retardants in Under-Ventilated Fires: Bench-Large-Scale Comparisons

    Directory of Open Access Journals (Sweden)

    David A. Purser

    2016-09-01

    Full Text Available In large-scale compartment fires; combustion product yields vary with combustion conditions mainly in relation to the fuel:air equivalence ratio (Φ and the effects of gas-phase flame retardants. Yields of products of inefficient combustion; including the major toxic products CO; HCN and organic irritants; increase considerably as combustion changes from well-ventilated (Φ < 1 to under-ventilated (Φ = 1–3. It is therefore essential that bench-scale toxicity tests reproduce this behaviour across the Φ range. Yield data from repeat compartment fire tests for any specific fuel show some variation on either side of a best-fit curve for CO yield as a function of Φ. In order to quantify the extent to which data from the steady state tube furnace (SSTF [1]; ISO TS19700 [2] represents compartment fire yields; the range and average deviations of SSTF data for CO yields from the compartment fire best-fit curve were compared to those for direct compartment fire measurements for six different polymeric fuels with textile and non-textile applications and for generic post-flashover fire CO yield data. The average yields; range and standard deviations of the SSTF data around the best-fit compartment fire curves were found to be close to those for the compartment fire data. It is concluded that SSTF data are as good a predictor of compartment fire yields as are repeat compartment fire test data.

  12. LITERATURE SURVEY ON ISOTOPIC ABUNDANCE RATIO MEASUREMENTS - 2001-2005

    International Nuclear Information System (INIS)

    HOLDEN, N.E.

    2005-01-01

    Along with my usual weekly review of the published literature for new nuclear data, I also search for new candidates for best measurements of isotopic abundances from a single source. Most of the published articles, that I previously had found in the Research Library at the Brookhaven Lab, have already been sent to the members of the Atomic Weights Commission, by either Michael Berglund or Thomas Walczyk. In the last few days, I checked the published literature for any other articles in the areas of natural variations in isotopic abundance ratios, measurements of isotopic abundance ratios on samples of extra-terrestrial material and isotopic abundance ratio measurements performed using ICPMS instruments. Hopefully this information will be of interest to members of the Commission, the sub-committee on isotopic abundance measurements (SIAM), members of the former sub-committee on natural isotopic fractionation (SNIF), the sub-committee on extra-terrestrial isotope ratios (SETIR), the RTCE Task Group and the Guidelines Task Group, who are dealing with ICPMS and TIMS comparisons. In the following report, I categorize the publications in one of four areas. Measurements performed using either positive or negative ions with Thermal Ionization Mass Spectrometer, TIMS, instruments; measurements performed on Inductively Coupled Plasma Mass Spectrometer, ICPMS, instruments; measurements of natural variations of the isotopic abundance ratios; and finally measurements on extra-terrestrial samples with instrumentation of either type. There is overlap in these areas. I selected out variations and ET results first and then categorized the rest of the papers by TIMS and ICPMS

  13. Measurement of Tau Branching Ratios to Five Charged Hadrons

    CERN Document Server

    Ackerstaff, K.; Allison, John; Altekamp, N.; Anderson, K.J.; Anderson, S.; Arcelli, S.; Asai, S.; Ashby, S.F.; Axen, D.; Azuelos, G.; Ball, A.H.; Barberio, E.; Barlow, Roger J.; Bartoldus, R.; Batley, J.R.; Baumann, S.; Bechtluft, J.; Behnke, T.; Bell, Kenneth Watson; Bella, G.; Bentvelsen, S.; Bethke, S.; Betts, S.; Biebel, O.; Biguzzi, A.; Bird, S.D.; Blobel, V.; Bloodworth, I.J.; Bobinski, M.; Bock, P.; Bohme, J.; Boutemeur, M.; Braibant, S.; Bright-Thomas, P.; Brown, Robert M.; Burckhart, H.J.; Burgard, C.; Burgin, R.; Capiluppi, P.; Carnegie, R.K.; Carter, A.A.; Carter, J.R.; Chang, C.Y.; Charlton, David G.; Chrisman, D.; Ciocca, C.; Clarke, P.E.L.; Clay, E.; Cohen, I.; Conboy, J.E.; Cooke, O.C.; Couyoumtzelis, C.; Coxe, R.L.; Cuffiani, M.; Dado, S.; Dallavalle, G.Marco; Davis, R.; De Jong, S.; del Pozo, L.A.; De Roeck, A.; Desch, K.; Dienes, B.; Dixit, M.S.; Doucet, M.; Dubbert, J.; Duchovni, E.; Duckeck, G.; Duerdoth, I.P.; Eatough, D.; Estabrooks, P.G.; Etzion, E.; Evans, H.G.; Fabbri, F.; Fanfani, A.; Fanti, M.; Faust, A.A.; Fiedler, F.; Fierro, M.; Fischer, H.M.; Fleck, I.; Folman, R.; Furtjes, A.; Futyan, D.I.; Gagnon, P.; Gary, J.W.; Gascon, J.; Gascon-Shotkin, S.M.; Geich-Gimbel, C.; Geralis, T.; Giacomelli, G.; Giacomelli, P.; Gibson, V.; Gibson, W.R.; Gingrich, D.M.; Glenzinski, D.; Goldberg, J.; Gorn, W.; Grandi, C.; Gross, E.; Grunhaus, J.; Gruwe, M.; Hanson, G.G.; Hansroul, M.; Hapke, M.; Hargrove, C.K.; Hartmann, C.; Hauschild, M.; Hawkes, C.M.; Hawkings, R.; Hemingway, R.J.; Herndon, M.; Herten, G.; Heuer, R.D.; Hildreth, M.D.; Hill, J.C.; Hillier, S.J.; Hobson, P.R.; Hocker, James Andrew; Homer, R.J.; Honma, A.K.; Horvath, D.; Hossain, K.R.; Howard, R.; Huntemeyer, P.; Igo-Kemenes, P.; Imrie, D.C.; Ishii, K.; Jacob, F.R.; Jawahery, A.; Jeremie, H.; Jimack, M.; Joly, A.; Jones, C.R.; Jovanovic, P.; Junk, T.R.; Karlen, D.; Kartvelishvili, V.; Kawagoe, K.; Kawamoto, T.; Kayal, P.I.; Keeler, R.K.; Kellogg, R.G.; Kennedy, B.W.; Klier, A.; Kluth, S.; Kobayashi, T.; Kobel, M.; Koetke, D.S.; Kokott, T.P.; Kolrep, M.; Komamiya, S.; Kowalewski, Robert V.; Kress, T.; Krieger, P.; von Krogh, J.; Kyberd, P.; Lafferty, G.D.; Lanske, D.; Lauber, J.; Lautenschlager, S.R.; Lawson, I.; Layter, J.G.; Lazic, D.; Lee, A.M.; Lefebvre, E.; Lellouch, D.; Letts, J.; Levinson, L.; Liebisch, R.; List, B.; Littlewood, C.; Lloyd, A.W.; Lloyd, S.L.; Loebinger, F.K.; Long, G.D.; Losty, M.J.; Ludwig, J.; Lui, D.; Macchiolo, A.; Macpherson, A.; Mannelli, M.; Marcellini, S.; Markopoulos, C.; Martin, A.J.; Martin, J.P.; Martinez, G.; Mashimo, T.; Mattig, Peter; McDonald, W.John; McKenna, J.; Mckigney, E.A.; McMahon, T.J.; McPherson, R.A.; Meijers, F.; Menke, S.; Merritt, F.S.; Mes, H.; Meyer, J.; Michelini, A.; Mihara, S.; Mikenberg, G.; Miller, D.J.; Mir, R.; Mohr, W.; Montanari, A.; Mori, T.; Nagai, K.; Nakamura, I.; Neal, H.A.; Nellen, B.; Nisius, R.; O'Neale, S.W.; Oakham, F.G.; Odorici, F.; Ogren, H.O.; Oreglia, M.J.; Orito, S.; Palinkas, J.; Pasztor, G.; Pater, J.R.; Patrick, G.N.; Patt, J.; Perez-Ochoa, R.; Petzold, S.; Pfeifenschneider, P.; Pilcher, J.E.; Pinfold, J.; Plane, David E.; Poffenberger, P.; Poli, B.; Polok, J.; Przybycien, M.; Rembser, C.; Rick, H.; Robertson, S.; Robins, S.A.; Rodning, N.; Roney, J.M.; Roscoe, K.; Rossi, A.M.; Rozen, Y.; Runge, K.; Runolfsson, O.; Rust, D.R.; Sachs, K.; Saeki, T.; Sahr, O.; Sang, W.M.; Sarkisian, E.K.G.; Sbarra, C.; Schaile, A.D.; Schaile, O.; Scharf, F.; Scharff-Hansen, P.; Schieck, J.; Schmitt, B.; Schmitt, S.; Schoning, A.; Schorner, T.; Schroder, Matthias; Schumacher, M.; Schwick, C.; Scott, W.G.; Seuster, R.; Shears, T.G.; Shen, B.C.; Shepherd-Themistocleous, C.H.; Sherwood, P.; Siroli, G.P.; Sittler, A.; Skuja, A.; Smith, A.M.; Snow, G.A.; Sobie, R.; Soldner-Rembold, S.; Sproston, M.; Stahl, A.; Stephens, K.; Steuerer, J.; Stoll, K.; Strom, David M.; Strohmer, R.; Stumpf, L.; Tafirout, R.; Talbot, S.D.; Tanaka, S.; Taras, P.; Tarem, S.; Teuscher, R.; Thiergen, M.; Thomson, M.A.; von Torne, E.; Torrence, E.; Towers, S.; Trigger, I.; Trocsanyi, Z.; Tsur, E.; Turcot, A.S.; Turner-Watson, M.F.; Van Kooten, Rick J.; Vannerem, P.; Verzocchi, M.; Vikas, P.; Voss, H.; Wackerle, F.; Wagner, A.; Ward, C.P.; Ward, D.R.; Watkins, P.M.; Watson, A.T.; Watson, N.K.; Wells, P.S.; Wermes, N.; White, J.S.; Wilson, G.W.; Wilson, J.A.; Wyatt, T.R.; Yamashita, S.; Yekutieli, G.; Zacek, V.; Zer-Zion, D.

    1999-01-01

    The branching ratios of the decay of the tau lepton to five charged hadrons have been measured with the OPAL detector at LEP using data collected between 1991 and 1995 at e+e- centre-of-mass energies close to the Z resonance. The branching ratios are measured to be BR(tau- to 3h-2h+nutau) = 0.091+-0.014+-0.005% BR(tau- to 3h-2h+pi0nutau) = 0.027+-0.018+-0.007% where the first error is statistical and the second systematic.

  14. Testing measurement equivalence of eudaimonic and hedonic entertainment motivations in a cross-cultural comparison

    OpenAIRE

    Odağ, Özen; Hofer, Matthias; Schneider, Frank M; Knop, Katharina

    2016-01-01

    Within Hofstede’s framework of individualistic and collectivistic cultures, this contribution examines measurement equivalence of hedonic and eudaimonic entertainment motivations in two different cultures, namely Germany representing a more individualistic culture (N = 180) and Turkey representing a more collectivistic culture (N = 97). By means of a multi-group confirmatory factor analysis, we could secure configural invariance for both hedonic and eudaimonic entertainment motivations across...

  15. Development, Reliability, and Equivalence of an Alternate Form for the CQ Duty Performance-Based Measure

    Science.gov (United States)

    2017-10-01

    CQD-O Funding Support: This grant None. 14 There were no other individuals who contributed at least one person month over the past year ...Dysfunction; W81XWH-14-1-0198). - Awarded funding for 2 new grants in the past year . The Purpose Project Feasibility Study (Engelsma Family Foundation) is...repeated as a post-treatment outcome measure due to learning effects. Therefore, an equivalent alternate form is needed. Research Question #1. Can an

  16. Evaluation of the water equivalence of solid phantoms using gamma ray transmission measurements

    International Nuclear Information System (INIS)

    Hill, R.F.; Brown, S.; Baldock, C.

    2008-01-01

    Gamma ray transmission measurements have been used to evaluate the water equivalence of solid phantoms. Technetium-99m was used in narrow beam geometry and the transmission of photons measured, using a gamma camera, through varying thickness of the solid phantom material and water. Measured transmission values were compared with Monte Carlo calculated transmission data using the EGSnrc Monte Carlo code to score fluence in a geometry similar to that of the measurements. The results indicate that the RMI457 Solid Water, CMNC Plastic Water and PTW RW3 solid phantoms had similar transmission values as compared to water to within ±1.5%. However, Perspex had a greater deviation in the transmission values up to ±4%. The agreement between the measured and EGSnrc calculated transmission values agreed to within ±1% over the range of phantom thickness studied. The linear attenuation coefficients at the gamma ray energy of 140.5 keV were determined from the measured and EGSnrc calculated transmission data and compared with predicted values derived from data provided by the National Institute of Standards and Technology (NIST) using the XCOM program. The coefficients derived from the measured data were up to 6% lower than those predicted by the XCOM program, while the coefficients determined from the Monte Carlo calculations were between measured and XCOM values. The results indicate that a similar process can be followed to determine the water equivalency of other solid phantoms and at other photon energies

  17. Magnetic Resonance Signal Intensity Ratio Measurement Before Uterine Artery Embolization

    DEFF Research Database (Denmark)

    Duvnjak, Stevo; Ravn, Pernille; Green, Anders

    2017-01-01

    , 52 patients were included in this prospective study. The SI ratio before UFE was calculated using circular region of interests placed on the dominant fibroid and the iliac muscle. The SI fibroid-to-iliac muscle ratio was calculated as SI of the dominant fibroid/SI of the iliac muscle on T1-, T2......-, and T1 post-contrast-weighted sequences. The dominant fibroid volume was measured and analyzed before and after UFE. RESULTS: In all, 46 patients who completed the three-month follow-up MRI were available for analysis. The correlation between SI fibroid-to-muscle ratio at the T2-weighted sequence...... positive correlation (r = 0.439, p T2-weighted sequence. The area under curve (AUC) for SI fibroid-to-muscle ratio on T2-weighted sequence was 0.776. For the other parameters, the AUC values were 0.512, 0.671, and 0.578, respectively. CONCLUSION: SI...

  18. What Do Contrast Threshold Equivalent Noise Studies Actually Measure? Noise vs. Nonlinearity in Different Masking Paradigms.

    Directory of Open Access Journals (Sweden)

    Alex S Baldwin

    Full Text Available The internal noise present in a linear system can be quantified by the equivalent noise method. By measuring the effect that applying external noise to the system's input has on its output one can estimate the variance of this internal noise. By applying this simple "linear amplifier" model to the human visual system, one can entirely explain an observer's detection performance by a combination of the internal noise variance and their efficiency relative to an ideal observer. Studies using this method rely on two crucial factors: firstly that the external noise in their stimuli behaves like the visual system's internal noise in the dimension of interest, and secondly that the assumptions underlying their model are correct (e.g. linearity. Here we explore the effects of these two factors while applying the equivalent noise method to investigate the contrast sensitivity function (CSF. We compare the results at 0.5 and 6 c/deg from the equivalent noise method against those we would expect based on pedestal masking data collected from the same observers. We find that the loss of sensitivity with increasing spatial frequency results from changes in the saturation constant of the gain control nonlinearity, and that this only masquerades as a change in internal noise under the equivalent noise method. Part of the effect we find can be attributed to the optical transfer function of the eye. The remainder can be explained by either changes in effective input gain, divisive suppression, or a combination of the two. Given these effects the efficiency of our observers approaches the ideal level. We show the importance of considering these factors in equivalent noise studies.

  19. SU-F-I-05: Dose Symmetry for CTDI Equivalent Measurements with Limited Angle CBCT

    Energy Technology Data Exchange (ETDEWEB)

    Singh, V [Henry Ford Hospital, Detroit, MI (United States); McKenney, S [Children’s National Medical Center, Washington, DC (United States); Sunde, P [Radcal, Inc, Monrovia, CA (United States); Feng, W [New York Presbyterian Hospital, Tenafly, NJ (United States); Bakalyar, D [Henry Ford Health System, Detroit, MI (United States)

    2016-06-15

    Purpose: CTDI measurements, useful for characterizing the x-ray output for multi-detector CT (MDCT), require a 360° rotation of the gantry; this presents a problem for cone beam CT (CBCT) due to its limited angular rotation. The purpose of this work is to demonstrate a methodology for overcoming this limited angular rotation so that CTDI measurements can also be made on CBCT systems making it possible to compare the radiation output from both types of system with a common metric. Methods: The symmetry of the CTDI phantom allows a 360° CTDI measurement to be replaced with two 180° measurements. A pencil chamber with a real-time digitizer was placed at the center of the head phantom (16 cm, PMMA) and the resulting exposure measurement from a 180° acquisition was doubled. A pair of edge measurements, each obtained with the gantry passing through the same 180 arc, was obtained with the pencil chamber at opposite edges of the diameter of the phantom and then summed. The method was demonstrated on a clinical CT scanner (Philips, Brilliance6) and then implemented on an interventional system (Siemens, Axiom Artis). Results: The equivalent CTDI measurement agreed with the conventional CTDI measurement within 8%. The discrepancy in the two measurements is largely attributed to uncertainties in cropping the waveform to a 180°acquisition. (Note: Because of the reduced fan angle in the CBCT, CTDI is not directly comparable to MDCT values when a 32 cm phantom is used.) Conclusion: The symmetry-based CTDI measurement is an equivalent measurement to the conventional CTDI measurement when the fan angle is large enough to encompass the phantom diameter. This allows a familiar metric of radiation output to be employed on systems with a limited angular rotation.

  20. Measurement of neutron dose equivalent outside and inside of the treatment vault of GRID therapy

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xudong; Charlton, Michael A.; Esquivel, Carlos; Eng, Tony Y.; Li, Ying; Papanikolaou, Nikos [University of Texas Health Science Center, San Antonio, Texas 78229 (United States)

    2013-09-15

    Purpose: To evaluate the neutron and photon dose equivalent rates at the treatment vault entrance (H{sub n,D} and H{sub G}), and to study the secondary radiation to the patient in GRID therapy. The radiation activation on the grid was studied.Methods: A Varian Clinac 23EX accelerator was working at 18 MV mode with a grid manufactured by .decimal, Inc. The H{sub n,D} and H{sub G} were measured using an Andersson–Braun neutron REM meter, and a Geiger Müller counter. The radiation activation on the grid was measured after the irradiation with an ion chamber γ-ray survey meter. The secondary radiation dose equivalent to patient was evaluated by etched track detectors and OSL detectors on a RANDO{sup ®} phantom.Results: Within the measurement uncertainty, there is no significant difference between the H{sub n,D} and H{sub G} with and without a grid. However, the neutron dose equivalent to the patient with the grid is, on average, 35.3% lower than that without the grid when using the same field size and the same amount of monitor unit. The photon dose equivalent to the patient with the grid is, on average, 44.9% lower. The measured average half-life of the radiation activation in the grid is 12.0 (±0.9) min. The activation can be categorized into a fast decay component and a slow decay component with half-lives of 3.4 (±1.6) min and 15.3 (±4.0) min, respectively. There was no detectable radioactive contamination found on the surface of the grid through a wipe test.Conclusions: This work indicates that there is no significant change of the H{sub n,D} and H{sub G} in GRID therapy, compared with a conventional external beam therapy. However, the neutron and scattered photon dose equivalent to the patient decrease dramatically with the grid and can be clinical irrelevant. Meanwhile, the users of a grid should be aware of the possible high dose to the radiation worker from the radiation activation on the surface of the grid. A delay in handling the grid after the beam

  1. The Galileo System of Measurement: Preliminary Evidence for Precision, Stability, and Equivalance to Traditional Measures

    Science.gov (United States)

    Gillham, James; Woelfel, Joseph

    1977-01-01

    Describes the Galileo system of measurement operations including reliability and validity data. Illustrations of some of the relations between Galileo measures and traditional procedures are provided. (MH)

  2. On the equivalence of generalized least-squares approaches to the evaluation of measurement comparisons

    Science.gov (United States)

    Koo, A.; Clare, J. F.

    2012-06-01

    Analysis of CIPM international comparisons is increasingly being carried out using a model-based approach that leads naturally to a generalized least-squares (GLS) solution. While this method offers the advantages of being easier to audit and having general applicability to any form of comparison protocol, there is a lack of consensus over aspects of its implementation. Two significant results are presented that show the equivalence of three differing approaches discussed by or applied in comparisons run by Consultative Committees of the CIPM. Both results depend on a mathematical condition equivalent to the requirement that any two artefacts in the comparison are linked through a sequence of measurements of overlapping pairs of artefacts. The first result is that a GLS estimator excluding all sources of error common to all measurements of a participant is equal to the GLS estimator incorporating all sources of error, including those associated with any bias in the standards or procedures of the measuring laboratory. The second result identifies the component of uncertainty in the estimate of bias that arises from possible systematic effects in the participants' measurement standards and procedures. The expression so obtained is a generalization of an expression previously published for a one-artefact comparison with no inter-participant correlations, to one for a comparison comprising any number of repeat measurements of multiple artefacts and allowing for inter-laboratory correlations.

  3. Testing for Measurement and Structural Equivalence in Large-Scale Cross-Cultural Studies: Addressing the Issue of Nonequivalence

    Science.gov (United States)

    Byrne, Barbara M.; van de Vijver, Fons J. R.

    2010-01-01

    A critical assumption in cross-cultural comparative research is that the instrument measures the same construct(s) in exactly the same way across all groups (i.e., the instrument is measurement and structurally equivalent). Structural equation modeling (SEM) procedures are commonly used in testing these assumptions of multigroup equivalence.…

  4. Comparison between measured and design dose rate equivalents on board of Nuclear Ship Mutsu

    International Nuclear Information System (INIS)

    Yamaji, Akio; Sakamoto, Yukio

    1993-01-01

    The power-up test of the Nuclear Ship Mutsu was restarted in March 1990 and completed successfully in February 1991. The experimental voyages were carried out for about one year and all experiments were completed in February 1992. A comparison between the measured and design dose rate equivalents on board is described with showing a modified method in the shielding design. The measured values were obtained extensively in the cavity between the primary and secondary shields, in the double bottom, outside the secondary shield, and on the surface of the main coolant loop. The shielding design calculations were made with the most conservative geometries and material compositions within the allowed tolerance. In addition, a conservative model was adopted in case of performing the approximation due to the geometrical restriction of calculation code. The computational accuracies were evaluated based on various experimental analyses. The evaluated value was used as the design value. The shield structures were determined with a judgement that the real value does not exceed the design value. The adequacy of the judgement was confirmed by measurements on board. The measured dose rate equivalents in all positions on board satisfied the design criteria. (author)

  5. Determination of the conversion coefficient for ambient dose equivalent, H(10), from air kerma measurements

    International Nuclear Information System (INIS)

    Gonzalez J, F.; Alvarez R, J. T.

    2015-09-01

    Namely the operational magnitudes can be determined by the product of a conversion coefficient by exposure air kerma or fluence, etc. In particular in Mexico for the first time is determined the conversion coefficient (Cc) for operational magnitude Environmental Dose Equivalent H(10) by thermoluminescence dosimetry (TLD) technique. First 30 TLD-100 dosimeters are calibrated in terms of air kerma, then these dosimeters are irradiated inside a sphere ICRU type of PMMA and with the aid of theory cavity the absorbed dose in PMMA is determined at a depth of 10 mm within the sphere D PMMA (10), subsequently absorbed dose to ICRU tissue is corrected and the dose equivalent H(10) is determined. The Cc is determined as the ratio of H(10)/K a obtaining a value of 1.20 Sv Gy -1 with a u c = 3.66%, this being consistent with the published value in ISO-4037-3 of 1.20 Sv Gy -1 with a u c = 2%. (Author)

  6. In vivo dissolution measurement with indium-111 summation peak ratios

    International Nuclear Information System (INIS)

    Jay, M.; Woodward, M.A.; Brouwer, K.R.

    1985-01-01

    Dissolution of [ 111 In]labeled tablets was measured in vivo in a totally noninvasive manner by using a modification of the perturbed angular correlation technique known as the summation peak ratio method. This method, which requires the incorporation of only 10-12 microCi into the dosage form, provided reliable dissolution data after oral administration of [ 111 In]lactose tablets. These results were supported by in vitro experiments which demonstrated that the dissolution rate as measured by the summation peak ratio method was in close agreement with the dissolution rate of salicylic acid in a [ 111 In]salicylic acid tablet. The method has the advantages of using only one detector, thereby avoiding the need for complex coincidence counting systems, requiring less radioactivity, and being potentially applicable to a gamma camera imaging system

  7. Measurement of boron isotope ratios in groundwater studies

    International Nuclear Information System (INIS)

    Porteous, N.C.; Walsh, J.N.; Jarvis, K.E.

    1995-01-01

    Boron is present at low levels in groundwater and rainfall in the UK, ranging between 2 and 200 ng ml -1 . A sensitive technique has been developed using inductively coupled plasma mass spectrometry (ICP-MS) to measure boron isotope ratios at low concentrations with a precision (s r ) of between 0.1 and 0.2%. Samples were evaporated to increase elemental boron concentrations to 200 ng ml -1 and interfering matrix elements were removed by an adapted cation-exchange separation procedure. The validity of measuring boron isotopic ratios by ICP-MS at this concentration level is discussed in relation to the theoretical instrument precision attainable based on counting statistics. (author)

  8. Test of tissue-equivalent scintillation detector for dose measurement of megavoltage beams

    International Nuclear Information System (INIS)

    Geso, M.; Ackerly, T.; Clift, M.A.

    2000-01-01

    Full text: The measurement of depth doses and profiles for a stereotactic radiotherapy beam presents special problems associated with the small beam size compared to the dosimeter's active detection area. In this work a locally fabricated organic plastic scintillator detector has been used to measure the depth dose and profile of a stereotactic radiotherapy beam. The 6MV beam is 1.25 cm diameter at isocentre, typical of small field stereotactic radiosurgery. The detector is a water/tissue equivalent plastic scintillator that is accompanied by Cerenkov subtraction detector. In this particular application, a negligible amount of Cerenkov light was detected. A photodiode and an electronic circuit is used instead of a photomultiplier for signal amplification. Comparison with data using a diode detector and a small size ionization chamber, indicate that the organic plastic scintillator detector is a valid detector for stereotactic radiosurgery dosimetry. The tissue equivalence of the organic scintillator also holds the promise of accurate dosimetry in the build up region. Depth doses measured using our plastic scintillator agree to within about 1% with those obtained using commercially available silicon diodes. Beam profiles obtained using plastic scintillator presents correct field width to within 0.35 mm, however some artifacts are visible in the profiles. These artifacts are about 5% discrepancy which has been shown not to be a significant factor in stereotactic radiotherapy dosimetry. Copyright (2000) Australasian College of Physical Scientists and Engineers in Medicine

  9. Measurement of the Λ→n+γ branching ratio

    International Nuclear Information System (INIS)

    Noble, A.J.; Larson, K.D.; Bassalleck, B.; Fickinger, W.J.; Hall, J.R.; Hallin, A.L.; Hasinoff, M.D.; Horvath, D.; Lowe, J.; McIntyre, E.K.; Measday, D.F.; Miller, J.P.; Roberts, B.L.; Robinson, D.K.; Sakitt, M.; Salomon, M.; Waltham, C.E.; Warner, T.M.; Whitehouse, D.A.; Wolfe, D.M.

    1992-01-01

    The branching ratio for the Λ weak radiative decay has been measured to be B(Λ→n+γ)/(Λ→anything) =[1.78±0.24(stat)± 0.16 0.14 (syst)]x10 -3 . A low-energy kaon beam was used to produce the Λ hyperons via the reaction K - +p→Λ+π 0 at rest. Photons from the signal channel and π 0 decay were detected with a NaI(Tl) array. The final spectrum contains 287 events after background subtraction, an order of magnitude more events than from the only previous measurement

  10. Equivalent circuit parameters of nickel/metal hydride batteries from sparse impedance measurements

    Science.gov (United States)

    Nelatury, Sudarshan Rao; Singh, Pritpal

    In a recent communication, a method for extracting the equivalent circuit parameters of a lead acid battery from sparse (only three) impedance spectroscopy observations at three different frequencies was proposed. It was based on an equivalent circuit consisting of a bulk resistance, a reaction resistance and a constant phase element (CPE). Such a circuit is a very appropriate model of a lead-acid cell at high state of charge (SOC). This paper is a sequel to it and presents an application of it in case of nickel/metal hydride (Ni/MH) batteries, which also at high SOC are represented by the same circuit configuration. But when the SOC of a Ni/MH battery under interrogation goes low, The EIS curve has a positive slope at the low frequency end and our technique yields complex values for the otherwise real circuit parameters, suggesting the need for additional elements in the equivalent circuit and a definite relationship between parameter consistency and SOC. To improvise the previous algorithm, in order that it works reasonably well at both high and low SOCs, we propose three more measurements—two at very low frequencies to include the Warburg response and one at a high frequency to model the series inductance, in addition to the three in the mid frequency band—totally six measurements. In most of the today's instrumentation, it is the user who should choose the circuit configuration and the number of frequencies where impedance should be measured and the accompanying software performs data fitting by complex nonlinear least squares. The proposed method has built into it an SOC-based decision-making capability—both to choose the circuit configuration and to estimate the values of the circuit elements.

  11. Effects of Tillage Systems on Changes of Soil Nutrients, Yield and Land Equivalent Ratio in Roselle – Green Gram Intercropping

    Directory of Open Access Journals (Sweden)

    A Hodiani mehr

    2017-10-01

    Full Text Available Introduction Intercropping is one of the components of sustainable agriculture and as part of crop rotation in the design of sustainable system. One of the benefits of intercropping is greater use of available resources. The aims of this study were to evaluate different tillage systems and cropping patterns of Roselle and Green Gram on some soil nutrients and the use efficiency of environmental resources. Usually, intercropping used at Low fertility soil with low input conditions in the tropics region. Bahrani et al. (2007 reported that no tillage systems compared with conventional tillage with crop residue, were increased soil organic carbon content in maize production. Ramroudi et al. (2011 expressed conventional tillage reduced amount of nitrogen compared to no tillage system. Material and Methods The research was conducted at Zabol city. Split plot experiment performed based on a randomized complete block design with three replications. Main plot was three levels of tillage system (zero (without plowing, reduced (disk and conventional tillage (disc plow and sub plot was planting ratio with five levels (pure culture of Roselle, pure culture of Green gram, 50% roselle+50% green gram, 25% roselle+75% green gram, 75% roselle+25% green gram were considered. Preparing the ground in mid-June 2012, according to the type of plowing was performed. For comparison of means were used by Duncan's test at 5% probability. Results and Discussion The effects of tillage systems, planting ratios and interaction of tillage systems × planting ratio on soil organic carbon and nitrogen were very significant. The highest and lowest levels of organic carbon were obtained in zero tillage (1.14% and conventional tillage systems (0.63 %, respectively. The highest and lowest nitrogen of soil after harvest, of pure culture of Green gram (0.11 % and 75 % of Roselle + 25% Green gram intercropping (0.06 % were obtained respectively, Tillage system could not affected the

  12. Blood pressure measurements in the ankle are not equivalent to blood pressure measurements in the arm.

    Science.gov (United States)

    Goldstein, Lara Nicole; Wells, Mike; Sliwa, Karen

    2014-07-25

    Blood pressure (BP) is often measured on the ankle in the emergency department (ED), but this has never been shown to be an acceptable alternative to measurements performed on the arm. To establish whether the differences between arm and ankle non-invasive BP measurements were clinically relevant (i.e. a difference of ≥10 mmHg). This was a prospective cross-sectional study in an urban ED making use of a convenience sample of 201 patients (18 - 50 years of age) who were not in need of emergency medical treatment. BP was measured in the supine position on both arms and ankles with the correct size cuff according to the manufacturer's guidelines. The arm and ankle BP measurements were compared. There was a clinically and statistically significant difference between arm and ankle systolic BP (SBP) and mean arterial pressure (MAP) (-13 mmHg, 95% confidence interval (CI) -28 - 1 mmHg and -5 mmHg, 95% CI -13 - 4 mmHg, respectively), with less difference in diastolic BP (DBP) (2 mmHg, 95% CI -7 - 10 mmHg). Only 37% of SBP measurements and 83% of MAP measurements were within an error range of 10 mmHg, while 95% of DBP measurements agreed within 10 mmHg. While the average differences (or the bias) were generally not large, large variations in individual patients (indicating poor precision) made the prediction of arm BP from ankle measurements unreliable. Ankle BP cannot be used as a substitute for arm BP in the ED.

  13. A Time-Measurement System Based on Isotopic Ratios

    International Nuclear Information System (INIS)

    Vo, Duc T.; Karpius, P.J.; MacArthur, D.W.; Thron, J.L.

    2007-01-01

    A time-measurement system can be built based on the ratio of gamma-ray peak intensities from two radioactive isotopes. The ideal system would use a parent isotope with a short half-life decaying to a long half-life daughter. The activities of the parent-daughter isotopes would be measured using a gamma-ray detector system. The time can then be determined from the ratio of the activities. The best-known candidate for such a system is the 241 Pu- 241 Am parent-daughter pair. However, this 241 Pu- 241 Am system would require a high-purity germanium detector system and sophisticated software to separate and distinguish between the many gamma-ray peaks produced by the decays of the two isotopes. An alternate system would use two different isotopes, again one with a short half-life and one with a half-life that is long relative to the other. The pair of isotopes 210 Pb and 241 Am (with half-lives of 22 and 432 years, respectively) appears suitable for such a system. This time-measurement system operates by measuring the change in the ratio of the 47-keV peak of 210 Pb to the 60-keV peak of 241 Am. For the system to work reasonably well, the resolution of the detector would need to be such that the two gamma-ray peaks are well separated so that their peak areas can be accurately determined using a simple region-of-interest (ROI) method. A variety of detectors were tested to find a suitable system for this application. The results of these tests are presented here.

  14. First measurement of the Omega /sup -/ decay branching ratios

    CERN Document Server

    Bourquin, M; Chatelus, Y; Chollet, J C; Degré, A; Froidevaux, D; Fyfe, A R; Gaillard, J M; Gee, C N P; Gibson, W M; Igo-Kemenes, P; Jeffreys, P W; Merkel, B; Morand, R; Plothow, H; Repellin, J P; Saunders, B J; Sauvage, G; Schiby, B; Siebert, H W; Smith, V J; Streit, K P; Strub, R; Thresher, J J; Tovey, Stuart N

    1979-01-01

    In an experiment in the CERN-SPS charged-hyperon beam, the main Omega /sup -/ decay branching ratios have been measured to be Gamma ( Omega /sup -/ to Lambda K/sup -/)/ Gamma (all)=0.686+or-0.013, Gamma ( Omega /sup -/ to Xi /sup 0/ pi /sup -/)/ Gamma (all) =0.234+or-0.013, Gamma ( Omega /sup -/ to Xi /sup -/ pi /sup 0/)/ Gamma (all)=0.080+or-0.008. The relative branching ratio of the two Xi pi modes provides a test of the Delta I=1/2 rule in decuplet-octet transitions. A search has also been made for the rare decay modes Omega /sup -/ to Lambda pi /sup -/, Omega /sup -/ to Xi /sup -/ gamma , Omega /sup -/ to Xi /sup -/ pi /sup +/ pi /sup -/ and Omega /sup -/ to Xi /sup 0/e/sup -/ nu . (6 refs).

  15. Measurements of thorium-B (212Pb) in the outdoor environment and evaluation of equivalent dose

    International Nuclear Information System (INIS)

    Mohammed, A.; El-Hussein, A.; Ali, A.E.

    2000-01-01

    The activity size distribution of unattached as well as attached 212 Pb to aerosol particles was measured in the open air of El-Minia City, Egypt. The samples were collected using a wire screen diffusion battery technique and a low pressure cascade impactor. The mean activity median thermodynamic diameter (AMTD) of unattached 212 Pb was determined to be 1.4 nm with a relative mean geometric standard deviation (σ g ) of 1.55. A mean unattached fraction (f p ) of 0.03±0.007 was obtained at a mean aerosol particle concentration of 32x10 3 cm -3 . Sometimes the f p values were less than the detection limit of 0.008. The mean concentration of activity of 212 Pb was found to be 9.6±1.1 mBq m -3 . The mean activity median aerodynamic diameter (AMAD) of the accumulation mode of attached 212 Pb was determined to be 360 nm with a mean (σ g ) of 2.7. The mean value of specific air activity concentration of 212 Pb associated with that mode was determined to be 303±12 mBq m -3 . With a dosimetric model calculation (International Commission on Radiological Protection. Human respiratory tract model for radiological protection. Oxford: Pergamon Press, ICRP Publication 66, 1994) the total deposition fractions as well as total equivalent and effective dose have been evaluated considering the obtained parameters of the activity size distributions. At a total deposition fraction of about 97% for unattached activities the total equivalent and effective doses to the lung were determined to be about 0.18 and 0.02 μSv, respectively, while total equivalent and effective doses of about 0.45 and 0.05 μ Sv, respectively, were determined at a total deposition fraction of about 23% for the attached activities

  16. The simulated measurements of area and personal neutron-gamma dose equivalent in the building of HWRR

    International Nuclear Information System (INIS)

    Chen Changmao; Wen Youqin; Su Jingling; Liu Shuying; Liu Nairong

    1988-01-01

    The measuring methods and results for area and personal n-γ dose equivalent in the building of HWRR of Institute of Atomic Energy were reported. The reactor operated 4440 hours during 1985, the average themal power was 11 MW. The average area n-γ dose equivalents of the basement, experimental hall, corridors and laboratories in the building were 12.2, 11.6, 0.45 and 0.23 cSv/a, respectively. The fraction of the neutron dose equivalent in any working area was less than 21%. The average personal n-γ dose equivalent to radiation workers in the building was about 0.49 cSv/a, the γ dose equivalent was a major component. The measuring methods were compared

  17. Race/ethnicity and measurement equivalence of the Everyday Discrimination Scale.

    Science.gov (United States)

    Kim, Giyeon; Sellbom, Martin; Ford, Katy-Lauren

    2014-09-01

    The present study examines the effect of race/ethnicity on measurement equivalence of the Everyday Discrimination Scale (EDS; Williams, Yu, Jackson, & Anderson, 1997). Drawn from the Collaborative Psychiatric Epidemiology Surveys (CPES; Alegría, Jackson, Kessler, & Takeuchi, 2008), adults aged 18 and older from four racial/ethnic groups were selected for analyses: 884 non-Hispanic Whites, 4,950 Blacks, 2,733 Hispanics/Latinos, and 2,089 Asians. Multiple-group confirmatory factor analyses were conducted. After adjusting for age and gender, the underlying construct of the EDS was invariant across four racial/ethnic groups, with Item 7 ("People act as if they're better than you are") associated with lower intercepts for the Hispanic/Latino and Asian groups relative to the non-Hispanic White and Black groups. In terms of latent factor differences, Blacks tended to score higher on the latent construct compared to other racial/ethnic groups, whereas Asians tended to score lower on the latent construct compared to Whites and Hispanics/Latinos. Findings suggest that although the EDS in general assesses the underlying construct of perceived discrimination equivalently across diverse racial/ethnic groups, caution is needed when Item 7 is used among Hispanics/Latinos or Asians. Implications are discussed in cultural and methodological contexts. PsycINFO Database Record (c) 2014 APA, all rights reserved.

  18. Measurement of the first Townsend ionization coefficient in a methane-based tissue-equivalent gas

    Energy Technology Data Exchange (ETDEWEB)

    Petri, A.R. [Instituto de Pesquisas Energéticas e Nucleares, Cidade Universitária, 05508-000 São Paulo (Brazil); Gonçalves, J.A.C. [Instituto de Pesquisas Energéticas e Nucleares, Cidade Universitária, 05508-000 São Paulo (Brazil); Departamento de Física, Pontifícia Universidade Católica de São Paulo, 01303-050 São Paulo (Brazil); Mangiarotti, A. [Instituto de Física - Universidade de São Paulo, Cidade Universitária, 05508-080 São Paulo (Brazil); Botelho, S. [Instituto de Pesquisas Energéticas e Nucleares, Cidade Universitária, 05508-000 São Paulo (Brazil); Bueno, C.C., E-mail: ccbueno@ipen.br [Instituto de Pesquisas Energéticas e Nucleares, Cidade Universitária, 05508-000 São Paulo (Brazil)

    2017-03-21

    Tissue-equivalent gases (TEGs), often made of a hydrocarbon, nitrogen, and carbon dioxide, have been employed in microdosimetry for decades. However, data on the first Townsend ionization coefficient (α) in such mixtures are scarce, regardless of the chosen hydrocarbon. In this context, measurements of α in a methane-based tissue-equivalent gas (CH{sub 4} – 64.4%, CO{sub 2} – 32.4%, and N{sub 2} – 3.2%) were performed in a uniform field configuration for density-normalized electric fields (E/N) up to 290 Td. The setup adopted in our previous works was improved for operating at low pressures. The modifications introduced in the apparatus and the experimental technique were validated by comparing our results of the first Townsend ionization coefficient in nitrogen, carbon dioxide, and methane with those from the literature and Magboltz simulations. The behavior of α in the methane-based TEG was consistent with that observed for pure methane. All the experimental results are included in tabular form in the .

  19. Equivalent dose measurements on board an Armenian Airline flight and Concord (9-17 km)

    International Nuclear Information System (INIS)

    Akopova, A.B.; Melkonyan, A.A.; Tatikyan, S.Sh.; Capdevielle, J-N.

    2002-01-01

    The results of investigations of the neutron component (E=1-10 MeV) of cosmic radiation on board the 'Armenian Airlines' aircrafts using nuclear photoemulsion are presented. The emulsions were exposed on the flights from Yerevan to Moscow, St.-Petersburg, Beirut, Athens, Frankfurt, Amsterdam, Paris and Sofia, and on Concord supersonic flights from Paris to New York. The dependence of the neutron fluxes, and on absorbed and equivalent doses on the flight parameters were investigated. On the flights of the supersonic Concord, with an altitude of 17 km, the neutron fluxes were essentially higher in comparison to those measured on Armenian airliners. It is interesting to note, that the neutron flux and equivalent dose rate decrease with altitude up to 470 km in space, for example, on board the STS-57. The shape of the differential energy spectrum for fast neutrons is the same on all Armenian airlines flights, but significantly different at 17 km altitude, where the flux in the energy region above 3 MeV is increasing

  20. Equivalent dose measurements on board an Armenian Airline flight and Concord (9-17 km)

    Energy Technology Data Exchange (ETDEWEB)

    Akopova, A.B. E-mail: akopova@lx2.yerphi.am; Melkonyan, A.A.; Tatikyan, S.Sh.; Capdevielle, J-N

    2002-12-01

    The results of investigations of the neutron component (E=1-10 MeV) of cosmic radiation on board the 'Armenian Airlines' aircrafts using nuclear photoemulsion are presented. The emulsions were exposed on the flights from Yerevan to Moscow, St.-Petersburg, Beirut, Athens, Frankfurt, Amsterdam, Paris and Sofia, and on Concord supersonic flights from Paris to New York. The dependence of the neutron fluxes, and on absorbed and equivalent doses on the flight parameters were investigated. On the flights of the supersonic Concord, with an altitude of 17 km, the neutron fluxes were essentially higher in comparison to those measured on Armenian airliners. It is interesting to note, that the neutron flux and equivalent dose rate decrease with altitude up to 470 km in space, for example, on board the STS-57. The shape of the differential energy spectrum for fast neutrons is the same on all Armenian airlines flights, but significantly different at 17 km altitude, where the flux in the energy region above 3 MeV is increasing.

  1. Aircraft gamma-ray spectrometry in snow-water equivalent measurement

    International Nuclear Information System (INIS)

    Kuittinen, R.; Vironmaeki, J.

    1979-01-01

    During the winter periods 1976-1977 and 1977-1978 the Hydrological Office at the National Board of Waters and the Geological Survey of Finland carried out a joint study to evaluate usefuluess of gamma-ray spectrometry in snow-water equivalent measurement. A multichannel gamma-ray spectrometer was fitted in a DC-3 aircraft. Fourteen snow courses were operated using both the gravimetric method and the gamma-ray method. The snow courses were located in southern Finland in forest, swamp and agricultural land. The results shows that the gamma ray method can be considered suitable for use in Finnish conditions and the accuracy of the gamma-ray method is almost of the same magnitude as the accuracy of the gravimetric method. (Auth.)

  2. Automated system for equivalent noise charge measurements from 10 ns to 10 μs

    International Nuclear Information System (INIS)

    La Taille, C. de.

    1992-07-01

    Noise measurements versus filter time constant constitute a very powerful method to investigate series, parallel and 1/f noise contributions in front end electronics. Usually performed with a set of filters and a multichannel analyser, they are tedious and often limited to values greater than 100 ns. A very low noise bipolar filter is described whose time constant can be selected via GPIB bus from 10 ns to 10 μs in 10 steps. The data are transferred from a digital scope to a computer which generates a baseline histogram and determines the overall gain. The Equivalent Noise Charge is then calculated for each time constant and a fit to the results determines the various noise parameters. (author) 13 refs., 10 figs., 1 tab

  3. Aircraft gamma-ray spectrometry in snow-water equivalent measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kuittinen, R [National Board of Waters (Finland); Vironmaeki, J [Geological Survey of Finland

    1979-01-01

    During the winter periods 1976-1977 and 1977-1978 the Hydrological Office at the National Board of Waters and the Geological Survey of Finland carried out a joint study to evaluate usefuluess of gamma-ray spectrometry in snow-water equivalent measurement. A multichannel gamma-ray spectrometer was fitted in a DC-3 aircraft. Fourteen snow courses were operated using both the gravimetric method and the gamma-ray method. The snow courses were located in southern Finland in forest, swamp and agricultural land. The results shows that the gamma ray method can be considered suitable for use in Finnish conditions and the accuracy of the gamma-ray method is almost of the same magnitude as the accuracy of the gravimetric method.

  4. Aircraft gamma-ray spectrometry in snow-water equivalent measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kuittinen, R; Vironmaeki, J

    1979-01-01

    During the winter periods of 1976 to 1977 and 1977 to 1978, the Hydrological Office at the National Boards of Waters and the Geological Survey of Finland carried out a joint study to evaluate usefulness of gamma-ray spectrometry in snowwater equivalent measurement. A multichannel gamma-ray spectrometry was fitted out in a DC-3 aircraft. Fourteen snow courses were operated using gravimetric method and gamma-ray method. The snow courses were located in southern Finland in forest, swamp and agricultural land. The results show that the gamma ray method can be considered suitable for use in Finnish conditions and the accuracy of the gamma-ray method is almost of the same magnitude of the accuracy of the gravimetric method.

  5. Measuring snow water equivalent from common-offset GPR records through migration velocity analysis

    Science.gov (United States)

    St. Clair, James; Holbrook, W. Steven

    2017-12-01

    Many mountainous regions depend on seasonal snowfall for their water resources. Current methods of predicting the availability of water resources rely on long-term relationships between stream discharge and snowpack monitoring at isolated locations, which are less reliable during abnormal snow years. Ground-penetrating radar (GPR) has been shown to be an effective tool for measuring snow water equivalent (SWE) because of the close relationship between snow density and radar velocity. However, the standard methods of measuring radar velocity can be time-consuming. Here we apply a migration focusing method originally developed for extracting velocity information from diffracted energy observed in zero-offset seismic sections to the problem of estimating radar velocities in seasonal snow from common-offset GPR data. Diffractions are isolated by plane-wave-destruction (PWD) filtering and the optimal migration velocity is chosen based on the varimax norm of the migrated image. We then use the radar velocity to estimate snow density, depth, and SWE. The GPR-derived SWE estimates are within 6 % of manual SWE measurements when the GPR antenna is coupled to the snow surface and 3-21 % of the manual measurements when the antenna is mounted on the front of a snowmobile ˜ 0.5 m above the snow surface.

  6. Measuring snow water equivalent from common-offset GPR records through migration velocity analysis

    Directory of Open Access Journals (Sweden)

    J. St. Clair

    2017-12-01

    Full Text Available Many mountainous regions depend on seasonal snowfall for their water resources. Current methods of predicting the availability of water resources rely on long-term relationships between stream discharge and snowpack monitoring at isolated locations, which are less reliable during abnormal snow years. Ground-penetrating radar (GPR has been shown to be an effective tool for measuring snow water equivalent (SWE because of the close relationship between snow density and radar velocity. However, the standard methods of measuring radar velocity can be time-consuming. Here we apply a migration focusing method originally developed for extracting velocity information from diffracted energy observed in zero-offset seismic sections to the problem of estimating radar velocities in seasonal snow from common-offset GPR data. Diffractions are isolated by plane-wave-destruction (PWD filtering and the optimal migration velocity is chosen based on the varimax norm of the migrated image. We then use the radar velocity to estimate snow density, depth, and SWE. The GPR-derived SWE estimates are within 6 % of manual SWE measurements when the GPR antenna is coupled to the snow surface and 3–21 % of the manual measurements when the antenna is mounted on the front of a snowmobile  ∼  0.5 m above the snow surface.

  7. Measurement of shoulder motion fraction and motion ratio

    International Nuclear Information System (INIS)

    Kang, Yeong Han

    2006-01-01

    This study was to understand about the measurement of shoulder motion fraction and motion ratio. We proposed the radiological criterior of glenohumeral and scapulothoracic movement ratio. We measured the motion fraction of the glenohumeral and scapulothoracic movement using CR (computed radiological system) of arm elevation at neutral, 90 degree, full elevation. Central ray was 15 .deg., 19 .deg., 22 .deg. to the cephald for the parallel scapular spine, and the tilting of torso was external oblique 40 .deg., 36 .deg., 22 .deg. for perpendicular to glenohumeral surface. Healthful donor of 100 was divided 5 groups by age (20, 30, 40, 50, 60). The angle of glenohumeral motion and scapulothoracic motion could be taken from gross arm angle and radiological arm angle. We acquired 3 images at neutral, 90 .deg. and full elevation position and measured radiographic angle of glenoheumeral, scapulothoracic movement respectively. While the arm elevation was 90 .deg., the shoulder motion fraction was 1.22 (M), 1.70 (W) in right arm and 1.31, 1.54 in left. In full elevation, Right arm fraction was 1.63, 1.84 and left was 1.57, 1.32. In right dominant arm (78%), 90 .deg. and Full motion fraction was 1.58, 1.43, in left (22%) 1.82, 1.94. In generation 20, 90 .deg. and Full motion fraction was 1.56, 1.52, 30' was 1.82, 1.43, 40' was 1.23, 1.16, 50' was 1.80, 1.28,60' was 1.24, 1.75. There was not significantly by gender, dominant arm and age. The criteria of motion fraction was useful reference for clinical diagnosis the shoulder instability

  8. Validation of daily urinary creatinine excretion measurement by muscle-creatinine equivalence.

    Science.gov (United States)

    Iacone, Roberto; D'Elia, Lanfranco; Guida, Bruna; Barbato, Antonio; Scanzano, Clelia; Strazzullo, Pasquale

    2018-02-09

    Twenty-four-hour urinary creatinine excretion (24hUCrE) is strongly correlated with skeletal muscle mass (SMM). This study suggests how to exploit the power of the SMM-24hUCrE correlation to assess the accuracy of 24hUCrE measurement. Four hundred and sixty-six men, a subgroup of participants in the 2002-2004 follow-up examination of the Olivetti Heart Study, performed a 24-h urine collection to measure 24hUCrE and underwent bioelectrical impedance analysis to evaluate SMM. Linear regression analysis between 24hUCrE and SMM was used to calculate the muscle-creatinine equivalence and to develop an equation to predict the 24hUCrE depending on SMM. The accuracy of the 24hUCrE measurement was assessed using the change in the SMM-24hUCrE correlation coefficient upon variation in the percentage deviation (%D) between the measured and predicted 24hUCrE. The calculated muscle-creatinine equivalence was 1 g of 24hUCrE = 22.73 kg of SMM. The %Ds and the corresponding SMM-24hUCrE correlation coefficients were as follows: %D = 3.0, r = .997; %D = 4.7, r = .989; %D = 8.1, r = .963; %D = 10.5, r = .940; %D = 12.6, r = .909; %D = 18.9, r = .825; %D = 25.8, r = .707; %D = 33.5, r = .595; %D = 41.4, r = .453. The increase in %D corresponds to a reduced correlation between muscle mass and creatinine excretion, which indicated a poor performance in the measurement of the 24hUCrE. For studies on single individuals, where small variations in 24hUCrE could be significant, a %D up to 12.6% is suggested; on the other hand, a wider %D interval could be acceptable for population studies. © 2018 Wiley Periodicals, Inc.

  9. An equivalent method of mixed dielectric constant in passive microwave/millimeter radiometric measurement

    Science.gov (United States)

    Su, Jinlong; Tian, Yan; Hu, Fei; Gui, Liangqi; Cheng, Yayun; Peng, Xiaohui

    2017-10-01

    Dielectric constant is an important role to describe the properties of matter. This paper proposes This paper proposes the concept of mixed dielectric constant(MDC) in passive microwave radiometric measurement. In addition, a MDC inversion method is come up, Ratio of Angle-Polarization Difference(RAPD) is utilized in this method. The MDC of several materials are investigated using RAPD. Brightness temperatures(TBs) which calculated by MDC and original dielectric constant are compared. Random errors are added to the simulation to test the robustness of the algorithm. Keywords: Passive detection, microwave/millimeter, radiometric measurement, ratio of angle-polarization difference (RAPD), mixed dielectric constant (MDC), brightness temperatures, remote sensing, target recognition.

  10. Measurement equivalence of the German Job Satisfaction Survey used in a multinational organization: implications of Schwartz's culture model.

    Science.gov (United States)

    Liu, Cong; Borg, Ingwer; Spector, Paul E

    2004-12-01

    The authors tested measurement equivalence of the German Job Satisfaction Survey (GJSS) using structural equation modeling methodology. Employees from 18 countries and areas provided data on 5 job satisfaction facets. The effects of language and culture on measurement equivalence were examined. A cultural distance hypothesis, based on S. H. Schwartz's (1999) theory, was tested with 4 cultural groups: West Europe, English speaking, Latin America, and Far East. Findings indicated the robustness of the GJSS in terms of measurement equivalence across countries. The survey maintained high transportability across countries speaking the same language and countries sharing similar cultural backgrounds. Consistent with Schwartz's model, a cultural distance effect on scale transportability among scales used in maximally dissimilar cultures was detected. Scales used in the West Europe group showed greater equivalence to scales used in the English-speaking and Latin America groups than scales used in the Far East group. 2004 APA, all rights reserved

  11. Toward Ensuring Health Equity: Readability and Cultural Equivalence of OMERACT Patient-reported Outcome Measures.

    Science.gov (United States)

    Petkovic, Jennifer; Epstein, Jonathan; Buchbinder, Rachelle; Welch, Vivian; Rader, Tamara; Lyddiatt, Anne; Clerehan, Rosemary; Christensen, Robin; Boonen, Annelies; Goel, Niti; Maxwell, Lara J; Toupin-April, Karine; De Wit, Maarten; Barton, Jennifer; Flurey, Caroline; Jull, Janet; Barnabe, Cheryl; Sreih, Antoine G; Campbell, Willemina; Pohl, Christoph; Duruöz, Mehmet Tuncay; Singh, Jasvinder A; Tugwell, Peter S; Guillemin, Francis

    2015-12-01

    The goal of the Outcome Measures in Rheumatology (OMERACT) 12 (2014) equity working group was to determine whether and how comprehensibility of patient-reported outcome measures (PROM) should be assessed, to ensure suitability for people with low literacy and differing cultures. The English, Dutch, French, and Turkish Health Assessment Questionnaires and English and French Osteoarthritis Knee and Hip Quality of Life questionnaires were evaluated by applying 3 readability formulas: Flesch Reading Ease, Flesch-Kincaid grade level, and Simple Measure of Gobbledygook; and a new tool, the Evaluative Linguistic Framework for Questionnaires, developed to assess text quality of questionnaires. We also considered a study assessing cross-cultural adaptation with/without back-translation and/or expert committee. The results of this preconference work were presented to the equity working group participants to gain their perspectives on the importance of comprehensibility and cross-cultural adaptation for PROM. Thirty-one OMERACT delegates attended the equity session. Twenty-six participants agreed that PROM should be assessed for comprehensibility and for use of suitable methods (4 abstained, 1 no). Twenty-two participants agreed that cultural equivalency of PROM should be assessed and suitable methods used (7 abstained, 2 no). Special interest group participants identified challenges with cross-cultural adaptation including resources required, and suggested patient involvement for improving translation and adaptation. Future work will include consensus exercises on what methods are required to ensure PROM are appropriate for people with low literacy and different cultures.

  12. Comparison of the Pentacam equivalent keratometry reading and IOL Master keratometry measurement in intraocular lens power calculations.

    Science.gov (United States)

    Karunaratne, Nicholas

    2013-12-01

    To compare the accuracy of the Pentacam Holladay equivalent keratometry readings with the IOL Master 500 keratometry in calculating intraocular lens power. Non-randomized, prospective clinical study conducted in private practice. Forty-five consecutive normal patients undergoing cataract surgery. Forty-five consecutive patients had Pentacam equivalent keratometry readings at the 2-, 3 and 4.5-mm corneal zone and IOL Master keratometry measurements prior to cataract surgery. For each Pentacam equivalent keratometry reading zone and IOL Master measurement the difference between the observed and expected refractive error was calculated using the Holladay 2 and Sanders, Retzlaff and Kraff theoretic (SRKT) formulas. Mean keratometric value and mean absolute refractive error. There was a statistically significantly difference between the mean keratometric values of the IOL Master, Pentacam equivalent keratometry reading 2-, 3- and 4.5-mm measurements (P variance). There was no statistically significant difference between the mean absolute refraction error for the IOL Master and equivalent keratometry readings 2 mm, 3 mm and 4.5 mm zones for either the Holladay 2 formula (P = 0.14) or SRKT formula (P = 0.47). The lowest mean absolute refraction error for Holladay 2 equivalent keratometry reading was the 4.5 mm zone (mean 0.25 D ± 0.17 D). The lowest mean absolute refraction error for SRKT equivalent keratometry reading was the 4.5 mm zone (mean 0.25 D ± 0.19 D). Comparing the absolute refraction error of IOL Master and Pentacam equivalent keratometry reading, best agreement was with Holladay 2 and equivalent keratometry reading 4.5 mm, with mean of the difference of 0.02 D and 95% limits of agreement of -0.35 and 0.39 D. The IOL Master keratometry and Pentacam equivalent keratometry reading were not equivalent when used only for corneal power measurements. However, the keratometry measurements of the IOL Master and Pentacam equivalent keratometry reading 4.5 mm may be

  13. Measurement of the equivalent dose in quartz using a regenerative-dose single-aliquot protocol

    International Nuclear Information System (INIS)

    Murray, A.S.; Roberts, R.G.

    1998-01-01

    The principles behind a regenerative-dose single-aliquot protocol are outlined. It is shown for three laboratory-bleached Australian sedimentary quartz samples that the relative change in sensitivity of the optically stimulated luminescence (OSL) during a repeated measurement cycle (consisting of a dose followed by a 10 s preheat at a given temperature and then a 100 s exposure to blue/green light at 125 deg. C) is very similar to that of the 110 deg. C thermoluminescence (TL) peak measured during the preheat cycle. The absolute change in the TL sensitivity with preheat temperature is different for samples containing a natural or a regenerative dose. Furthermore, the absolute change in sensitivity in both the OSL and TL signals is non-linear with regeneration cycle, but the relative change in the OSL signal compared to the following 110 deg. C TL measurement is well approximated by a straight line. Both signals are thought to use the same luminescence centres, and so some common behaviour is not unexpected. A new regenerative-dose protocol is presented which makes use of this linear relationship to correct for sensitivity changes with regeneration cycle, and requires only one aliquot for the estimation of the equivalent dose (D e ). The protocol has been applied to quartz from nine Australian sites. To illustrate the value of the regenerative-dose single-aliquot approach, the apparent values of D e for 13 samples, containing doses of between 0.01 and 100 Gy, have been measured at various preheat temperatures of between 160 and 300 deg. C, using a single aliquot for each D e measurement. Excellent agreement is found between these single-aliquot estimates of D e and those obtained from additive-dose multiple-aliquot and single-aliquot protocols, over the entire dose range

  14. Techniques for enhancing durability and equivalence ratio control in a rich-lean, three-stage ground power gas turbine combustor

    Science.gov (United States)

    Schultz, D. F.

    1982-01-01

    Rig tests of a can-type combustor were performed to demonstrate two advanced ground power engine combustor concepts: steam cooled rich-burn combustor primary zones for enhanced durability; and variable combustor geometry for three stage combustion equivalence ratio control. Both concepts proved to be highly successful in achieving their desired objectives. The steam cooling reduced peak liner temperatures to less than 800 K. This offers the potential of both long life and reduced use of strategic materials for liner fabrication. Three degrees of variable geometry were successfully implemented to control airflow distribution within the combustor. One was a variable blade angle axial flow air swirler to control primary airflow while the other two consisted of rotating bands to control secondary and tertiary or dilution air flow.

  15. Metabolic equivalents of task are confounded by adiposity, which disturbs objective measurement of physical activity

    Directory of Open Access Journals (Sweden)

    Tuomo T Tompuri

    2015-08-01

    Full Text Available Physical activity refers any bodily movements produced by skeletal muscles that expends energy. Hence the amount and the intensity of physical activity can be assessed by energy expenditure. Metabolic equivalents of task (MET are multiplies of the resting metabolism reflecting metabolic rate during exercise. The standard MET is defined as 3.5 ml/min/kg. However, the expression of energy expenditure by body weight to normalize the size differences between subjects causes analytical hazards: scaling by body weight does not have a physiological, mathematical, or physical rationale. This review demonstrates by examples that false methodology may cause paradoxical observations if physical activity would be assessed by body weight scaled values such as standard METs. While standard METs are confounded by adiposity, lean mass proportional measures of energy expenditure would enable a more truthful choice to assess physical activity. While physical activity as a behavior and cardiorespiratory fitness or adiposity as a state represents major determinants of public health, specific measurements of health determinants must be understood to enable a truthful evaluation of the interactions and their independent role as a health predictor.

  16. Well-being as a moving target: measurement equivalence of the Bradburn Affect Balance Scale.

    Science.gov (United States)

    Maitland, S B; Dixon, R A; Hultsch, D F; Hertzog, C

    2001-03-01

    Although the Bradburn Affect Balance scale (ABS) is a frequently used two-factor indicator of well-being in later life, its measurement and invariance properties are not well documented. We examined these issues using confirmatory factor analyses of cross-sectional (adults ages 54-87 years) and longitudinal data from the Victoria Longitudinal Study. Stability of the positive and negative affect factors was moderate across a 3-year period. Overall, factor loadings for positive affect items were invariant over time with the exception of the pleased item. Negative affect items were time invariant. However, age-group comparisons between young-old and old-old groups revealed age differences in loadings for the upset item at Time 1. Finally, gender groups differed in loadings for the top of the world and going your way items. Thus a pattern of partial measurement equivalence characterized item response to the ABS. Our results suggest that group comparisons and longitudinal change in ABS scale scores of positive and negative affect should be interpreted with caution.

  17. Regional inter-comparison of measurements of personal dose equivalent Hp(10) using photon beams

    International Nuclear Information System (INIS)

    Bero, M.; Zahili, M.; Kharita, M.H.

    2012-11-01

    The overall objective is to verify performance and to improve the Individual Monitoring services (IMS). This can be achieved with the following specific objectives of the intercomparison:1. To assess the capabilities of the dosimetry services to measure the quantity H p (10) in photon (gamma and x-ray) fields. 2. To help the participating Member States in achieving sufficiently accurate dosimetry service and, if necessary, 3. To provide guidelines for improvements and not simply a test of the performance of the existing dosimetric service. Actually a significant improvement has been achieved by the participants in the accuracy of evaluating personal dose equivalent from 15% in the first phase to 5% in the second phase. Some participants used the results of the inter-comparison to verify the calibration and to improve their dosimetric procedures, but from the results it was clear that some participants need to a technical support especially in calibration and using their measuring system in the field of personal monitoring. The conclusion contains advises, solutions, propositions and evaluation for all situations which noticed during the intercomparison. (authors)

  18. Equilibrium gas-oil ratio measurements using a microfluidic technique.

    Science.gov (United States)

    Fisher, Robert; Shah, Mohammad Khalid; Eskin, Dmitry; Schmidt, Kurt; Singh, Anil; Molla, Shahnawaz; Mostowfi, Farshid

    2013-07-07

    A method for measuring the equilibrium GOR (gas-oil ratio) of reservoir fluids using microfluidic technology is developed. Live crude oils (crude oil with dissolved gas) are injected into a long serpentine microchannel at reservoir pressure. The fluid forms a segmented flow as it travels through the channel. Gas and liquid phases are produced from the exit port of the channel that is maintained at atmospheric conditions. The process is analogous to the production of crude oil from a formation. By using compositional analysis and thermodynamic principles of hydrocarbon fluids, we show excellent equilibrium between the produced gas and liquid phases is achieved. The GOR of a reservoir fluid is a key parameter in determining the equation of state of a crude oil. Equations of state that are commonly used in petroleum engineering and reservoir simulations describe the phase behaviour of a fluid at equilibrium state. Therefore, to accurately determine the coefficients of an equation of state, the produced gas and liquid phases have to be as close to the thermodynamic equilibrium as possible. In the examples presented here, the GORs measured with the microfluidic technique agreed with GOR values obtained from conventional methods. Furthermore, when compared to conventional methods, the microfluidic technique was simpler to perform, required less equipment, and yielded better repeatability.

  19. Cross-cultural measurement equivalence of the EQ-5D-5L items for English-speaking Asians in Singapore.

    Science.gov (United States)

    Luo, N; Wang, Y; How, C H; Wong, K Y; Shen, L; Tay, E G; Thumboo, J; Herdman, M

    2015-06-01

    To investigate how the response labels of the 5-level EQ-5D (EQ-5D-5L) items are interpreted and used by English-speaking Chinese and non-Chinese Singaporeans, as a means to assessing whether those items are cross-culturally equivalent health-status measures in this Asian population. In face-to-face interviews, Chinese, Malay and Indian visitors to a primary care institution in Singapore were asked to rate the relative severity conveyed by EQ-5D-5L response labels, each containing the keyword of 'no(t),' 'slight(ly),' 'moderate(ly),' 'severe(ly),' or 'unable'/'extreme(ly),' using a 0-100 numerical rating scale. Participants were also asked to describe 25 hypothetical health states using the EQ-5D-5L response labels. Differences between Chinese and Malay/Indian participants in label interpretation and selection were examined using multivariate regression analysis to adjust for participant characteristics. The differences in adjusted mean severity scores for individual EQ-5D-5L labels between Chinese (n = 148) and non-Chinese (Malay: n = 53; Indian: n = 56) participants ranged from 0.0 to 9.0. The relative severity of the labels to the participants supported the ordinality of the EQ-5D-5L response labels and was similar across ethnic groups. Chinese and non-Chinese participants selected similar response labels to describe each hypothetical health state, with the adjusted odds ratios of selecting any type of the five response labels for non-Chinese versus Chinese participants ranging from 0.92 to 1.15 (p > 0.05 for all). The EQ-5D-5L items are likely to generate equivalent health outcomes between English-speaking Chinese and non-Chinese Singaporeans.

  20. Noise Measurements of High Aspect Ratio Distributed Exhaust Systems

    Science.gov (United States)

    Bridges, James E.

    2015-01-01

    This paper covers far-field acoustic measurements of a family of rectangular nozzles with aspect ratio 8, in the high subsonic flow regime. Several variations of nozzle geometry, commonly found in embedded exhaust systems, are explored, including bevels, slants, single broad chevrons and notches, and internal septae. Far-field acoustic results, presented previously for the simple rectangular nozzle, showed that increasing aspect ratio increases the high frequency noise, especially directed in the plane containing the minor axis of the nozzle. Detailed changes to the nozzle geometry generally made little difference in the noise, and the differences were greatest at low speed. Having an extended lip on one broad side (bevel) did produce up to 3 decibels more noise in all directions, while extending the lip on the narrow side (slant) produced up to 2 decibels more noise, primarily on the side with the extension. Adding a single, non-intrusive chevron, made no significant change to the noise, while inverting the chevron (notch) produced up to 2decibels increase in the noise. Having internal walls (septae) within the nozzle, such as would be required for structural support or when multiple fan ducts are aggregated, reduced the noise of the rectangular jet, but could produce a highly directional shedding tone from the septae trailing edges. Finally, a nozzle with both septae and a beveled nozzle, representative of the exhaust system envisioned for a distributed electric propulsion aircraft with a common rectangular duct, produced almost as much noise as the beveled nozzle, with the septae not contributing much reduction in noise.

  1. Developing a single-aliquot protocol for measuring equivalent dose in biogenic carbonates

    International Nuclear Information System (INIS)

    Stirling, R.J.; Duller, G.A.T.; Roberts, H.M.

    2012-01-01

    Exploiting biogenic carbonates as thermoluminescence dosimeters requires an understanding of trap kinetics and an appropriate sequence with which to measure equivalent dose. The trap kinetics of two high temperature peaks (peaks II and III) from calcitic snail opercula have been investigated resulting in the calculation of lifetimes of 7.4 × 10 7 and 1.4 × 10 11 years for the two peaks respectively. Two measurement sequences, based upon changes in the application and measurement of a test dose, have been applied to peaks II and III, and though both methods were equally successful in dose recovery and production of a dose response curve some differences were observed. Primarily, the use of method 1 lead to dose dependant sensitivity change implying competition effects occurring during irradiation; method 2 did not experience this phenomenon. As a consequence method 2 was chosen as the most appropriate protocol for single-aliquot dating of this material. When assessing the TL behaviour of the two peaks, peak II performed poorly in dose recovery experiments recovering a dose 60–100% larger than that applied. Disproportionate growth of peak II in response to a beta dose applied prior to measurement, compared to growth following regeneration doses indicated that peak II was not suitable for use in single-aliquot protocols. However, dose recovery results for peak III were all within errors of unity of the given dose, and peak III was therefore chosen as the most appropriate peak for TL dosimetry in these single-aliquot procedures. The lifetime of charge in peak III is sufficient to date over many millions of years, and furthermore using the chosen method 2 the dose response curve has a D 0 of 3,250 ± 163 Gy allowing dating to over 3 million years.

  2. Measuring Depression in a Non-Western War-Affected Displaced Population: Measurement Equivalence of the Beck Depression Inventory

    Directory of Open Access Journals (Sweden)

    Nuwan Jayawickreme

    2017-09-01

    Full Text Available Depression is commonly seen in survivors of conflict and disaster across the world. There is a dearth of research on the validity of commonly used measures of depression in these populations. Measurements of depression that are used in multiple contexts need to meet measurement equivalence, i.e., the instrument measures the same construct in the same manner across different groups. The Beck Depression Inventory (BDI was administered to female trauma survivors in the United States (n = 268 and female survivors of war in Sri Lanka (n = 149. Three metrics of measurement equivalence—structural, metric, and scalar—were examined. Two- and three-factor structures of the BDI that have been identified in other populations did not provide a good fit for our data. However, a bifactor model revealed a similar general distress dimension across populations, but dissimilar secondary dimensions or subfactors. The Sri Lankan subfactor comprised of predominantly somatic symptoms and the United States subfactor comprised of cognitive and somatic symptoms. While intercepts of individual BDI items differed, their differences seem to be offsetting. Total BDI scores across these two populations are roughly comparable, although caution is recommended when interpreting them. Making comparisons on subscales is not recommended.

  3. A method to generate equivalent energy spectra and filtration models based on measurement for multidetector CT Monte Carlo dosimetry simulations

    International Nuclear Information System (INIS)

    Turner, Adam C.; Zhang Di; Kim, Hyun J.; DeMarco, John J.; Cagnon, Chris H.; Angel, Erin; Cody, Dianna D.; Stevens, Donna M.; Primak, Andrew N.; McCollough, Cynthia H.; McNitt-Gray, Michael F.

    2009-01-01

    The purpose of this study was to present a method for generating x-ray source models for performing Monte Carlo (MC) radiation dosimetry simulations of multidetector row CT (MDCT) scanners. These so-called ''equivalent'' source models consist of an energy spectrum and filtration description that are generated based wholly on the measured values and can be used in place of proprietary manufacturer's data for scanner-specific MDCT MC simulations. Required measurements include the half value layers (HVL 1 and HVL 2 ) and the bowtie profile (exposure values across the fan beam) for the MDCT scanner of interest. Using these measured values, a method was described (a) to numerically construct a spectrum with the calculated HVLs approximately equal to those measured (equivalent spectrum) and then (b) to determine a filtration scheme (equivalent filter) that attenuates the equivalent spectrum in a similar fashion as the actual filtration attenuates the actual x-ray beam, as measured by the bowtie profile measurements. Using this method, two types of equivalent source models were generated: One using a spectrum based on both HVL 1 and HVL 2 measurements and its corresponding filtration scheme and the second consisting of a spectrum based only on the measured HVL 1 and its corresponding filtration scheme. Finally, a third type of source model was built based on the spectrum and filtration data provided by the scanner's manufacturer. MC simulations using each of these three source model types were evaluated by comparing the accuracy of multiple CT dose index (CTDI) simulations to measured CTDI values for 64-slice scanners from the four major MDCT manufacturers. Comprehensive evaluations were carried out for each scanner using each kVp and bowtie filter combination available. CTDI experiments were performed for both head (16 cm in diameter) and body (32 cm in diameter) CTDI phantoms using both central and peripheral measurement positions. Both equivalent source model types

  4. Study of response of radiation monitors for environmental dose equivalent measurements

    International Nuclear Information System (INIS)

    Souza, Macilene N.; Khoury, H.J.

    2005-01-01

    The environmental dose equivalent H * (10), is the magnitude recommended by ICRU 39 for environmental monitoring in fields of radiation of photons. Most of the equipment used for area monitoring, only quantifies the magnitudes exposure or dose not being designed to this new magnitude. In Brazil, particularly, is not yet regulated the use of H * (10). However, with the revision of the standard 3.01 it will necessary the use of monitors that allow the achievement of measures according to H * (10). The transition for using new magnitudes will be a slow process and the contribution that the laboratories of metrology of ionizing radiation in the country can give is, at first, promote and create the habit of using the unit Sievert (Sv) in the calibration of the instruments, and that is the unit recommended for H * (10). In a second step, the tests for determining the response of the instruments for H * (10) should be made and this is the harder step, taking into account the large number of area monitors around the country. These tests will provide information about the limitations of the instrument to the new magnitude, that is, the range where the instrument will have the best performance in quantification of new magnitude. This paper evaluates the performance for H * (10), with the variation of energy and angle of incidence of radiation, of three of the most used monitors in the country

  5. The equivalence of two phylogenetic biodiversity measures: the Shapley value and Fair Proportion index.

    Science.gov (United States)

    Hartmann, Klaas

    2013-11-01

    Most biodiversity conservation programs are forced to prioritise species in order to allocate their funding. This paper contains a mathematical proof that provides biological support for one common approach based on phylogenetic indices. Phylogenetic trees describe the evolutionary relationships between a group of taxa. Two indices for computing the distinctiveness of each taxon in a phylogenetic tree are considered here-the Shapley value and the Fair Proportion index. These indices provide a measure of the importance of each taxon for overall biodiversity and have been used to prioritise taxa for conservation. The Shapley value is the biodiversity contribution a taxon is expected to make if all taxa are equally likely to become extinct. This interpretation makes it appealing to use the Shapley value in biodiversity conservation applications. The Fair Proportion index lacks a convenient interpretation, however it is significantly easier to calculate and understand. It has been empirically observed that there is a high correlation between the two indices. This paper shows the mathematical basis for this correlation and proves that as the number of taxa increases, the indices become equivalent. Consequently in biodiversity prioritisation the simpler Fair Proportion index can be used whilst retaining the appealing interpretation of the Shapley value.

  6. A measurable Lawson criterion and hydro-equivalent curves for inertial confinement fusion

    International Nuclear Information System (INIS)

    Zhou, C. D.; Betti, R.

    2008-01-01

    It is shown that the ignition condition (Lawson criterion) for inertial confinement fusion (ICF) can be cast in a form dependent on the only two parameters of the compressed fuel assembly that can be measured with existing techniques: the hot spot ion temperature (T i h ) and the total areal density (ρR tot ), which includes the cold shell contribution. A marginal ignition curve is derived in the ρR tot , T i h plane and current implosion experiments are compared with the ignition curve. On this plane, hydrodynamic equivalent curves show how a given implosion would perform with respect to the ignition condition when scaled up in the laser-driver energy. For 3 i h > n i h > n 2.6 · tot > n >50 keV 2.6 · g/cm 2 , where tot > n and i h > n are the burn-averaged total areal density and hot spot ion temperature, respectively. Both quantities are calculated without accounting for the alpha-particle energy deposition. Such a criterion can be used to determine how surrogate D 2 and subignited DT target implosions perform with respect to the one-dimensional ignition threshold.

  7. Quantifying sex, race, and age specific differences in bone microstructure requires measurement of anatomically equivalent regions.

    Science.gov (United States)

    Ghasem-Zadeh, Ali; Burghardt, Andrew; Wang, Xiao-Fang; Iuliano, Sandra; Bonaretti, Serena; Bui, Minh; Zebaze, Roger; Seeman, Ego

    2017-08-01

    Individuals differ in forearm length. As microstructure differs along the radius, we hypothesized that errors may occur when sexual and racial dimorphisms are quantified at a fixed distance from the radio-carpal joint. Microstructure was quantified ex vivo in 18 cadaveric radii using high resolution peripheral quantitative computed tomography and in vivo in 158 Asian and Caucasian women and men at a fixed region of interest (ROI), a corrected ROI positioned at 4.5-6% of forearm length and using the fixed ROI adjusted for cross sectional area (CSA), forearm length or height. Secular effects of age were assessed by comparing 38 younger and 33 older women. Ex vivo, similar amounts of bone mass fashioned adjacent cross sections. Larger distal cross sections had thinner porous cortices of lower matrix mineral density (MMD), a larger medullary CSA and higher trabecular density. Smaller proximal cross-sections had thicker less porous cortices of higher MMD, a small medullary canal with little trabecular bone. Taller persons had more distally positioned fixed ROIs which moved proximally when corrected. Shorter persons had more proximally positioned fixed ROIs which moved distally when corrected, so dimorphisms lessened. In the corrected ROIs, in Caucasians, women had 0.6 SD higher porosity and 0.6 SD lower trabecular density than men (pmicrostructure requires measurement of anatomically equivalent regions. Copyright © 2017 Elsevier Inc. All rights reserved.

  8. Measurement equivalence of the BDSx scale with young and older adults with bipolar disorder.

    Science.gov (United States)

    O'Rourke, Norm; Bachner, Yaacov G; Canham, Sarah L; Sixsmith, Andrew; Study Team, Badas

    2018-05-01

    Instruments developed for mental health research are commonly devised and validated with young adults only. However, the measurement properties of these scales may differ over the lifespan. For this study, we set out to demonstrate the psychometric equivalence of the BDSx scale with an international sample of young and older adults with bipolar disorder (BD). We independently replicated the 4-factor model of BDSx responses with young and older participants (M = 45.63, range 19-87 years of age); we then compared the psychometric properties between models. This allowed us to compare responses to each BDSx item between groups, and the strength of association among depression and hypo/mania factors (cognitive depressive symptoms, somatic depressive symptoms, affrontive symptoms of hypo/mania, elation/loss of insight). Young and older adults responded to 19 of 20 BDSx items in similar ways. Only responses to the 'talkative' item were significantly higher for younger adults. Correlations between depression and mania factors are statistically indistinguishable between age groups. This suggests that symptoms cluster and present similarly for young and older adults with BD. The BDSx is currently being used for ecological momentary sampling of mood by the BADAS (Bipolar Affective Disorder and older Adults) Study app for iPhone. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Velocity ratio measurement using the frequency of gyro backward wave

    International Nuclear Information System (INIS)

    Muggli, P.; Tran, M.Q.; Tran, T.M.

    1990-10-01

    The operating diagram of a low quality factor, 8GHz TE 01 0 gyrotron exhibits oscillations between 6.8 and 7.3GHz. These oscillations are identified as the backward wave component of the TE 21 0 traveling mode. As the resonance condition of this mode depends on the average parallel velocity [ > of the beam electrons (ω BW ≅Ω C /γ - k [ [ >), the measurement of ω BW for given Ω C and γ, is used as a diagnostic for the beam electrons velocity ratio α= / [ >. The values of α, deduced from ω BW through the linear dispersion relation for the electron cyclotron instability in an infinite waveguide, are unrealistic. A non-linear simulation code gives α values which are in very good agreement with the ones predicted by a particle trajectory code (+10% to +20%). We find numerically that the particles' velocity dispersion in vperpendicular and v [ increases ω BW . This effect explains part of the discrepancy between the values of α inferred from ω BW without velocity dispersion and the expected values. (author) 10 refs., 6 figs., 1 tab

  10. Measuring the differences in work ratios between pediatric and adult ophthalmologic examinations.

    Science.gov (United States)

    Hyun, Joo; Chang, Jee Ho; Kim, Seung Hoon; Park, Song Hee; Kim, Sunghoon

    2017-06-01

    To assess the differences in work needed for pediatric and adult ophthalmologic examinations. Seven ophthalmology residents conducted slit-lamp and refraction examinations on children 3-7 years of age and adults 20-69 years of age. The examiners reported the magnitude estimate (ME) of their work in relation to two references (cross-reference ME): average adult examination and average pediatric examination. The examination time was also measured. For the slit-lamp examination, 50 children and 58 adults were recruited. The ME was 1.45 (95% CI, 1.30-1.62) times higher for the pediatric examinations than for the adult examinations when the reference was an average adult case. With respect to time, the pediatric examinations took 1.22 (95% CI, 1.06-1.41) times longer than the adult examinations. For the refraction examinations, 58 children and 96 adults were recruited. The ME was 1.35 (95% CI, 1.21-1.52) times higher for the pediatric examinations. The pediatric examination took 1.32 (95% CI, 1.16-1.50) times longer than the adult examination. The cross-reference ME ratios measuring the pediatric over adult examinations against both the pediatric and adult reference cases were equivalent in both the slit-lamp and the refraction examinations; however, the ME and time ratios of the pediatric over the adult examinations were not equivalent for the slit-lamp or for the refraction examinations. The cross-reference ME showed that pediatric ophthalmologic examinations require more work than the adult examination with validity and reliability. The time estimate was insufficient as a single indicator for work estimation. Copyright © 2017 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  11. Testing measurement equivalence of experienced holiday quality: Evidence on built-in bias in the Flash Eurobarometer survey data

    NARCIS (Netherlands)

    Gelissen, J.P.T.M.

    2018-01-01

    In this contribution, we evaluate the degree of measurement equivalence between countries and over time for a measure of experienced holiday quality that has repeatedly been included in a public opinion survey series of high policy relevance: the Flash Eurobarometer survey series (2014–2016). The

  12. The lack of cross-national equivalence of a therapist adherence measure (TAM-R) in multisystemic therapy (MST)

    NARCIS (Netherlands)

    Lange, A.M.C.; Scholte, R.H.J.; Geffen, W. van; Timman, R.; Busschbach, J.J.V. van; Rijken, R.E.A. van der

    2016-01-01

    This two-study report investigates the equivalence of the Dutch Therapist Adherence Measure Revised (TAM-R) to the US original. The TAM-R is a questionnaire measuring therapist adherence to the treatment model of Multisystemic Therapy (MST). Monitoring of therapist adherence is essential for

  13. The Effect of Small Sample Size on Measurement Equivalence of Psychometric Questionnaires in MIMIC Model: A Simulation Study

    Directory of Open Access Journals (Sweden)

    Jamshid Jamali

    2017-01-01

    Full Text Available Evaluating measurement equivalence (also known as differential item functioning (DIF is an important part of the process of validating psychometric questionnaires. This study aimed at evaluating the multiple indicators multiple causes (MIMIC model for DIF detection when latent construct distribution is nonnormal and the focal group sample size is small. In this simulation-based study, Type I error rates and power of MIMIC model for detecting uniform-DIF were investigated under different combinations of reference to focal group sample size ratio, magnitude of the uniform-DIF effect, scale length, the number of response categories, and latent trait distribution. Moderate and high skewness in the latent trait distribution led to a decrease of 0.33% and 0.47% power of MIMIC model for detecting uniform-DIF, respectively. The findings indicated that, by increasing the scale length, the number of response categories and magnitude DIF improved the power of MIMIC model, by 3.47%, 4.83%, and 20.35%, respectively; it also decreased Type I error of MIMIC approach by 2.81%, 5.66%, and 0.04%, respectively. This study revealed that power of MIMIC model was at an acceptable level when latent trait distributions were skewed. However, empirical Type I error rate was slightly greater than nominal significance level. Consequently, the MIMIC was recommended for detection of uniform-DIF when latent construct distribution is nonnormal and the focal group sample size is small.

  14. The Effect of Small Sample Size on Measurement Equivalence of Psychometric Questionnaires in MIMIC Model: A Simulation Study.

    Science.gov (United States)

    Jamali, Jamshid; Ayatollahi, Seyyed Mohammad Taghi; Jafari, Peyman

    2017-01-01

    Evaluating measurement equivalence (also known as differential item functioning (DIF)) is an important part of the process of validating psychometric questionnaires. This study aimed at evaluating the multiple indicators multiple causes (MIMIC) model for DIF detection when latent construct distribution is nonnormal and the focal group sample size is small. In this simulation-based study, Type I error rates and power of MIMIC model for detecting uniform-DIF were investigated under different combinations of reference to focal group sample size ratio, magnitude of the uniform-DIF effect, scale length, the number of response categories, and latent trait distribution. Moderate and high skewness in the latent trait distribution led to a decrease of 0.33% and 0.47% power of MIMIC model for detecting uniform-DIF, respectively. The findings indicated that, by increasing the scale length, the number of response categories and magnitude DIF improved the power of MIMIC model, by 3.47%, 4.83%, and 20.35%, respectively; it also decreased Type I error of MIMIC approach by 2.81%, 5.66%, and 0.04%, respectively. This study revealed that power of MIMIC model was at an acceptable level when latent trait distributions were skewed. However, empirical Type I error rate was slightly greater than nominal significance level. Consequently, the MIMIC was recommended for detection of uniform-DIF when latent construct distribution is nonnormal and the focal group sample size is small.

  15. Politico-economic equivalence

    DEFF Research Database (Denmark)

    Gonzalez Eiras, Martin; Niepelt, Dirk

    2015-01-01

    Traditional "economic equivalence'' results, like the Ricardian equivalence proposition, define equivalence classes over exogenous policies. We derive "politico-economic equivalence" conditions that apply in environments where policy is endogenous and chosen sequentially. A policy regime and a st......Traditional "economic equivalence'' results, like the Ricardian equivalence proposition, define equivalence classes over exogenous policies. We derive "politico-economic equivalence" conditions that apply in environments where policy is endogenous and chosen sequentially. A policy regime...... their use in the context of several applications, relating to social security reform, tax-smoothing policies and measures to correct externalities....

  16. Lalinet status - station expansion and lidar ratio systematic measurements

    Directory of Open Access Journals (Sweden)

    Landulfo Eduardo

    2018-01-01

    Full Text Available LALINET is expanding regionally to guarantee spatial coverage over South and Central Americas. One of the network goals is to obtain a set of regional representative aerosol optical properties such as particle backscatter, extinction and lidar ratio. Given the North-South extension and influence of distinct airmass circulation patterns it is paramount to distinguish these optical parameters in order to gain better perfomance in radiation transfer models. A set of lidar ratio data is presented.

  17. Simulation studies on a prototype ionization chamber for measurement of personal dose equivalent, Hp(10)

    International Nuclear Information System (INIS)

    Cardoso, J.; Oliveira, C.; Carvalho, A.F.

    2005-01-01

    Full text: The Metrological Laboratory of lonizing Radiation and Radioactivity (LMRIR) of Nuclear and Technological Institute (ITN) has designed and constructed a prototype ionization chamber for direct measurement of the personal dose equivalent, H p (10), similar to the developed by the Physikalisch-Technische Bundesanstalt (PTB) and now commercialized by PTW. Tests already performed had shown that the behaviour of this chamber is very close to the PTB chamber, namely the energy dependence for the x-ray radiation qualities of the ISO 4037-1 narrow series N-30, N-40, N-60, N-80, N-100 and N-120 and also for gamma radiation of 137 Cs and 60 Co. However, the results obtained also show a high dependence on the energy for some incident radiation angles and a low magnitude of the electrical response of the ionization chamber. In order to try to optimize the performance of the chamber, namely to decrease the energy dependence and to improve the magnitude of the electrical response of the ionization chamber, the LMRIR initiated numerical simulation of this ionization chamber using a Monte-Carlo method for simulation of radiation transport using, in a first step, the MCNPX code. So, simulation studies of some physical parameters are been performed in order to optimize the response of the ionization chamber, namely the diameter of the central electrode of the ionization chamber, the thickness of the front wall of the ionization chamber, among others. Preliminary results show that probably the actual geometry of the ionization chamber is not yet the optimized configuration. The simulation study will carry on in order to find the optimum geometry. (author)

  18. Combining virtual observatory and equivalent source dipole approaches to describe the geomagnetic field with Swarm measurements

    Science.gov (United States)

    Saturnino, Diana; Langlais, Benoit; Amit, Hagay; Civet, François; Mandea, Mioara; Beucler, Éric

    2018-03-01

    A detailed description of the main geomagnetic field and of its temporal variations (i.e., the secular variation or SV) is crucial to understanding the geodynamo. Although the SV is known with high accuracy at ground magnetic observatory locations, the globally uneven distribution of the observatories hampers the determination of a detailed global pattern of the SV. Over the past two decades, satellites have provided global surveys of the geomagnetic field which have been used to derive global spherical harmonic (SH) models through some strict data selection schemes to minimise external field contributions. However, discrepancies remain between ground measurements and field predictions by these models; indeed the global models do not reproduce small spatial scales of the field temporal variations. To overcome this problem we propose to directly extract time series of the field and its temporal variation from satellite measurements as it is done at observatory locations. We follow a Virtual Observatory (VO) approach and define a global mesh of VOs at satellite altitude. For each VO and each given time interval we apply an Equivalent Source Dipole (ESD) technique to reduce all measurements to a unique location. Synthetic data are first used to validate the new VO-ESD approach. Then, we apply our scheme to data from the first two years of the Swarm mission. For the first time, a 2.5° resolution global mesh of VO time series is built. The VO-ESD derived time series are locally compared to ground observations as well as to satellite-based model predictions. Our approach is able to describe detailed temporal variations of the field at local scales. The VO-ESD time series are then used to derive global spherical harmonic models. For a simple SH parametrization the model describes well the secular trend of the magnetic field both at satellite altitude and at the surface. As more data will be made available, longer VO-ESD time series can be derived and consequently used to

  19. Measured Neutron Spectra and Dose Equivalents From a Mevion Single-Room, Passively Scattered Proton System Used for Craniospinal Irradiation

    Energy Technology Data Exchange (ETDEWEB)

    Howell, Rebecca M., E-mail: rhowell@mdanderson.org [Department of Radiation Physics, The University of Texas M. D. Anderson Cancer Center, Houston, Texas (United States); Burgett, Eric A.; Isaacs, Daniel [Department of Nuclear Engineering, Idaho State University, Pocatello, Idaho (United States); Price Hedrick, Samantha G.; Reilly, Michael P.; Rankine, Leith J.; Grantham, Kevin K.; Perkins, Stephanie; Klein, Eric E. [Department of Radiation Oncology, Washington University, St. Louis, Missouri (United States)

    2016-05-01

    Purpose: To measure, in the setting of typical passively scattered proton craniospinal irradiation (CSI) treatment, the secondary neutron spectra, and use these spectra to calculate dose equivalents for both internal and external neutrons delivered via a Mevion single-room compact proton system. Methods and Materials: Secondary neutron spectra were measured using extended-range Bonner spheres for whole brain, upper spine, and lower spine proton fields. The detector used can discriminate neutrons over the entire range of the energy spectrum encountered in proton therapy. To separately assess internally and externally generated neutrons, each of the fields was delivered with and without a phantom. Average neutron energy, total neutron fluence, and ambient dose equivalent [H* (10)] were calculated for each spectrum. Neutron dose equivalents as a function of depth were estimated by applying published neutron depth–dose data to in-air H* (10) values. Results: For CSI fields, neutron spectra were similar, with a high-energy direct neutron peak, an evaporation peak, a thermal peak, and an intermediate continuum between the evaporation and thermal peaks. Neutrons in the evaporation peak made the largest contribution to dose equivalent. Internal neutrons had a very low to negligible contribution to dose equivalent compared with external neutrons, largely attributed to the measurement location being far outside the primary proton beam. Average energies ranged from 8.6 to 14.5 MeV, whereas fluences ranged from 6.91 × 10{sup 6} to 1.04 × 10{sup 7} n/cm{sup 2}/Gy, and H* (10) ranged from 2.27 to 3.92 mSv/Gy. Conclusions: For CSI treatments delivered with a Mevion single-gantry proton therapy system, we found measured neutron dose was consistent with dose equivalents reported for CSI with other proton beamlines.

  20. Laser induced breakdown in gas mixtures. Experimental and statistical investigation on n-decane ignition: Pressure, mixture composition and equivalence ratio effects.

    Science.gov (United States)

    Mokrani, Nabil; Gillard, Philippe

    2018-03-26

    This paper presents a physical and statistical approach to laser-induced breakdown in n-decane/N 2  + O 2 mixtures as a function of incident or absorbed energy. A parametric study, with pressure, fuel purity and equivalence ratio, was conducted to determine the incident and absorbed energies involved in producing breakdown, followed or not by ignition. The experiments were performed using a Q-switched Nd-YAG laser (1064 nm) inside a cylindrical 1-l combustion chamber in the range of 1-100 mJ of incident energy. A stochastic study of breakdown and ignition probabilities showed that the mixture composition had a significant effect on ignition with large variation of incident or absorbed energy required to obtain 50% of breakdown. It was observed that the combustion products absorb more energy coming from the laser. The effect of pressure on the ignition probabilities of lean and near stoichiometric mixtures was also investigated. It was found that a high ignition energy E50% is required for lean mixtures at high pressures (3 bar). The present study provides new data obtained on an original experimental setup and the results, close to laboratory-produced laser ignition phenomena, will enhance the understanding of initial conditions on the breakdown or ignition probabilities for different mixtures. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Gasification of Rice Husk in a Downdraft Gasifier: The Effect of Equivalence Ratio on the Gasification Performance, Properties, and Utilization Analysis of Byproducts of Char and Tar

    Directory of Open Access Journals (Sweden)

    Zhongqing Ma

    2015-03-01

    Full Text Available Rice husks (RH are a potential biomass source for bio-energy production in China, such as bio-gas production by gasification technology. In this paper, a bench-scale downdraft fixed bed gasifier (DFBG and a tar sampling system were designed. The effect of equivalence ratio (ER on gasification performance in terms of the temperature in the gasifier, the composition distribution of the producer gas, and the tar content in the producer gas was studied. The maximum lower heating value of 4.44 MJ/Nm3, minimum tar content of 1.34 g/Nm3, and maximum cold gas efficiency of 50.85% were obtained at ER of 0.211. In addition, the characteristics of gasification byproducts, namely bio-char and bio-tar, were analyzed. The proximate and ultimate analysis (especially of the alkali metal, the surface morphology, the surface area, and the pore size distribution of the rice husk char (RHC were obtained by the use of X-ray fluorescence (XRF and scanning electron microscopy (SEM, as well as by using the Brunauer-Emmett-Teller (BET method. The components of light tar and heavy tar were obtained by using gas chromatography-mass spectrometry (GC-MS.

  2. The cross-cultural equivalence of parental rearing measure : EAABU-C

    NARCIS (Netherlands)

    Dekovic, M; ten Have, M; Vollebergh, WAM; Pels, T; Oosterwegel, A; Wissink, IB; De Winter, AF; Verhulst, FC; Ormel, J

    2006-01-01

    We examined the cross-cultural equivalence of a widely used instrument that assesses perceived parental rearing, the EMBU-C, among native Dutch and immigrant adolescents living in The Netherlands. The results of a multigroup confirmatory factor analysis indicated that the factor structure of the

  3. Tail asymptotics for the supremum of an infinitely divisible field with convolution equivalent Lévy measure

    DEFF Research Database (Denmark)

    Rønn-Nielsen, Anders; Jensen, Eva B. Vedel

    We consider a continuous, infinitely divisible random field in Rd given as an integral of a kernel function with respect to a Lévy basis with convolution equivalent Lévy measure. For a large class of such random fields we compute the asymptotic probability that the supremum of the field exceeds...

  4. Retrieval of Effective Correlation Length and Snow Water Equivalent from Radar and Passive Microwave Measurements

    Directory of Open Access Journals (Sweden)

    Juha Lemmetyinen

    2018-01-01

    Full Text Available Current methods for retrieving SWE (snow water equivalent from space rely on passive microwave sensors. Observations are limited by poor spatial resolution, ambiguities related to separation of snow microstructural properties from the total snow mass, and signal saturation when snow is deep (~>80 cm. The use of SAR (Synthetic Aperture Radar at suitable frequencies has been suggested as a potential observation method to overcome the coarse resolution of passive microwave sensors. Nevertheless, suitable sensors operating from space are, up to now, unavailable. Active microwave retrievals suffer, however, from the same difficulties as the passive case in separating impacts of scattering efficiency from those of snow mass. In this study, we explore the potential of applying active (radar and passive (radiometer microwave observations in tandem, by using a dataset of co-incident tower-based active and passive microwave observations and detailed in situ data from a test site in Northern Finland. The dataset spans four winter seasons with daily coverage. In order to quantify the temporal variability of snow microstructure, we derive an effective correlation length for the snowpack (treated as a single layer, which matches the simulated microwave response of a semi-empirical radiative transfer model to observations. This effective parameter is derived from radiometer and radar observations at different frequencies and frequency combinations (10.2, 13.3 and 16.7 GHz for radar; 10.65, 18.7 and 37 GHz for radiometer. Under dry snow conditions, correlations are found between the effective correlation length retrieved from active and passive measurements. Consequently, the derived effective correlation length from passive microwave observations is applied to parameterize the retrieval of SWE using radar, improving retrieval skill compared to a case with no prior knowledge of snow-scattering efficiency. The same concept can be applied to future radar

  5. Errors in estimating neutron quality factor using lineal energy distributions measured in tissue-equivalent proportional counters

    International Nuclear Information System (INIS)

    Borak, T.B.; Stinchcomb, T.G.

    1982-01-01

    Neutron dose equivalent is obtained from quality factors which are defined in terms of LET. It is possible to estimate the dose averaged quality factor, antiQ, directly from distributions in lineal energy, y, that are measured in tissue-equivalent proportional counters. This eliminates a mathematical transformation of the absorbed dose from D(y) to D(L). We evaluate the inherent error in computing Q from D(y) rather than D(L) for neutron spectra below 4 MeV. The effects of neutron energy and simulated tissue diameters within a gas cavity are examined in detail. (author)

  6. Measuring liquidity on stock market: impact on liquidity ratio

    OpenAIRE

    Siniša Bogdan; Suzana Bareša; Saša Ivanović

    2012-01-01

    The purpose – It is important to emphasize that liquidity on Croatian stock market is low, the purpose of this paper is to test empirically and find out which variables make crucial role in decision making process of investing in stocks. Design – This paper explores the impact of various liquidity variables on liquidity ratio since it is still insufficiently researched topic. Methodology –This research uses secondary and primary data available from Croatian stock market. Considering pri...

  7. The equivalent circuit of single crab muscle fibers as determined by impedance measurements with intracellular electrodes.

    Science.gov (United States)

    Eisenberg, R S

    1967-07-01

    The input impedance of muscle fibers of the crab was determined with microelectrodes over the frequency range 1 cps to 10 kc/sec. Care was taken to analyze, reduce, and correct for capacitive artifact. One dimensional cable theory was used to determine the properties of the equivalent circuit of the membrane admittance, and the errors introduced by the neglect of the three dimensional spread of current are discussed. In seven fibers the equivalent circuit of an element of the membrane admittance must contain a DC path and two capacitances, each in series with a resistance. In two fibers, the element of membrane admittance could be described by one capacitance in parallel with a resistance. In several fibers there was evidence for a third very large capacitance. The values of the elements of the equivalent circuit depend on which of several equivalent circuits is chosen. The circuit (with a minimum number of elements) that was considered most reasonably consistent with the anatomy of the fiber has two branches in parallel: one branch having a resistance R(e) in series with a capacitance C(e); the other branch having a resistance R(b) in series with a parallel combination of a resistance R(m) and a capacitance C(m). The average circuit values (seven fibers) for this model, treating the fiber as a cylinder of sarcolemma without infoldings or tubular invaginations, are R(e) = 21 ohm cm(2); C(e) = 47 microf/cm(2); R(b) = 10.2 ohm cm(2); R(m) = 173 ohm cm(2); C(m) = 9.0 microf/cm(2). The relation of this equivalent circuit and another with a nonminimum number of circuit elements to the fine structure of crab muscle is discussed. In the above equivalent circuit R(m) and C(m) are attributed to the sarcolemma; R(e) and C(e), to the sarcotubular system; and R(b), to the amorphous material found around crab fibers. Estimates of actual surface area of the sarcolemma and sarcotubular system permit the average circuit values to be expressed in terms of unit membrane area. The

  8. Application of combined TLD and CR-39 PNTD method for measurement of total dose and dose equivalent on ISS

    International Nuclear Information System (INIS)

    Benton, E.R.; Deme, S.; Apathy, I.

    2006-01-01

    To date, no single passive detector has been found that measures dose equivalent from ionizing radiation exposure in low-Earth orbit. We have developed the I.S.S. Passive Dosimetry System (P.D.S.), utilizing a combination of TLD in the form of the self-contained Pille TLD system and stacks of CR-39 plastic nuclear track detector (P.N.T.D.) oriented in three mutually orthogonal directions, to measure total dose and dose equivalent aboard the International Space Station (I.S.S.). The Pille TLD system, consisting on an on board reader and a large number of Ca 2 SO 4 :Dy TLD cells, is used to measure absorbed dose. The Pille TLD cells are read out and annealed by the I.S.S. crew on orbit, such that dose information for any time period or condition, e.g. for E.V.A. or following a solar particle event, is immediately available. Near-tissue equivalent CR-39 P.N.T.D. provides Let spectrum, dose, and dose equivalent from charged particles of LET ∞ H 2 O ≥ 10 keV/μm, including the secondaries produced in interactions with high-energy neutrons. Dose information from CR-39 P.N.T.D. is used to correct the absorbed dose component ≥ 10 keV/μm measured in TLD to obtain total dose. Dose equivalent from CR-39 P.N.T.D. is combined with the dose component <10 keV/μm measured in TLD to obtain total dose equivalent. Dose rates ranging from 165 to 250 μGy/day and dose equivalent rates ranging from 340 to 450 μSv/day were measured aboard I.S.S. during the Expedition 2 mission in 2001. Results from the P.D.S. are consistent with those from other passive detectors tested as part of the ground-based I.C.C.H.I.B.A.N. intercomparison of space radiation dosimeters. (authors)

  9. Noise equivalent count measurements in a neuro-PET scanner with retractable septa

    International Nuclear Information System (INIS)

    Bailey, D.L.; Jones, T.; Spinks, T.J.; Gilardi, M.C.; Townsend, D.W.

    1990-01-01

    This paper reports on the removal of interplane septa in a PET scanner that enables acquisition of all possible lines of response (3D mode) in an effort to maximize the available number of detected events. One problem with this method at high countrates, however, is a markedly increased deadtime and randoms rate, which has a deleterious effect on data quality. The noise-equivalent countrate (NEC) performance of a neuro-PET scanner has been determined with and without interplane septa on uniform cylindrical phantoms of differing radii and in human studies to assess the optimum countrate conditions that realize the maximum gain. In the brain, the effective gain in NEC performance for 3D ranges from >5 at low countrates to ∼3.3 at 200 kcps (equivalent to 37 kcps in 2D). The gains of the 3D method assessed by this analysis are significant, and are shown to be highly dependent on countrate and object dimensions

  10. Development of neutron dosimeter using CR-39 for measurement of ambient dose equivalent

    International Nuclear Information System (INIS)

    Maki, Daisuke; Shinozaki, Wakako; Ohguchi, Hiroyuki; Yamamoto, Takayoshi; Nakamura, Takayoshi

    2010-01-01

    A CR-39 has good advantages such as cumulative type dosimeter, small fading effect and gamma-ray insensitive. Therefore, we developed the wide energy-range environmental neutron dosimeter using eight CR-39s for area monitoring in this study. This dosimeter is made of octagonal columnar polyethylene block which height is 60 mm and bottom side is 25 mm. The dosimeter contains two types of CR-39s for fast neutron detection and slow neutron detection. Four CR-39s for fast neutron detection are used for detection of recoil protons produced by H (n, p) reactions. Four CR-39s for slow neutron detection are used with boron nitride converter to detect alpha-rays produced by 10 B (n, α) 7 Li reactions. Ambient dose equivalent is obtained by adding the number of etch-pits observed in four CR-39s for fast neutron detection to the number of etch-pits observed in four CR-39s for slow neutron detection with appropriate constants respectively. Dosimeters were irradiated with some energetic neutrons and evaluated results of ambient dose equivalent were compared with results from neutron transport calculations. Energy response of dosimeter shows good agreement with neutron fluence to ambient dose equivalent conversion coefficients. Directional dependence of dosimeter is at the same level as the rem-counter. (author)

  11. Dynamic Equivalent Modeling of a Grid-Tied Microgrid Based on Characteristic Model and Measurement Data

    Directory of Open Access Journals (Sweden)

    Changchun Cai

    2017-11-01

    Full Text Available Microgrids can significantly improve the utilization of distributed generation (DG and the reliability of the power supply. However, in the grid-tied operational mode, the interaction between the microgrid and the distribution network cannot be ignored. The paper proposes an equivalent modeling method for the microgrid under grid-tied mode based on a characteristic model. It can simplify the microgrid model in the numerical simulation of the distribution network. The proposed equivalent model can present the dynamic response of a microgrid but not miss any of its primary characteristics. The characteristic model is represented by a low-order time-varying differential equation with the same characteristics of the original microgrid system. During the modeling process, the voltage and the power exchanged between the microgrid and distribution network are collected as the training data for the identification of model parameters. A recursive damped least squares algorithm (RDLS is used for the parameter identification. A microgrid system containing different DGs is built to test the proposed modeling method in DIgSILENT, and the results show that the proposed dynamic equivalent modeling method is effective and the characteristic model can present the dynamic behaviors of the detailed model of a microgrid.

  12. Covariances for measured activation and fission ratios data

    International Nuclear Information System (INIS)

    Smith, D.L.; Meadows, J.W.; Watanabe, Y.

    1986-01-01

    Methods which are routinely used in the determination of covariance matrices for both integral and differential activation and fission-ratios data acquired at the Argonne National Laboratory Fast-Neutron Generator Facility (FNG) are discussed. Special consideration is given to problems associated with the estimation of correlations between various identified sources of experimental error. Approximation methods which are commonly used to reduce the labor involved in this analysis to manageable levels are described. Results from some experiments which have been recently carried out in this laboratory are presented to illustrate these procedures. 13 refs., 1 fig., 5 tabs

  13. Effects of finite aspect ratio on wind turbine airfoil measurements

    DEFF Research Database (Denmark)

    Kiefer, Janik; Miller, Mark A.; Hultmark, Marcus

    2016-01-01

    Wind turbines partly operate in stalled conditions within their operational cycle. To simulate these conditions, it is also necessary to obtain 2-D airfoil data in terms of lift and drag coefficients at high angles of attack. Such data has been obtained previously, but often at low aspect ratios...... and only barely past the stall point, where strong wall boundary layer influence is expected. In this study, the influence of the wall boundary layer on 2D airfoil data, especially in the post stall domain, is investigated. Here, a wind turbine airfoil is tested at different angles of attack and with two...

  14. Simulation and experimental study of an indigenously designed and constructed THGEM-based microdosimeter for dose-equivalent measurement

    International Nuclear Information System (INIS)

    Moslehi, A.; Raisali, G.; Lamehi, M.

    2016-01-01

    Most of the GEM/THGEM-based microdosimetric detectors presented in the literature simulate 2 μm of tissue which results in a flat neutron dose-equivalent response in the MeV region. The objective of this work was to introduce a neutron microdosimeter with a more extended flat response. In this regard, a THGEM-based microdosimeter with plexiglas walls, simulating 1 μm of tissue was designed and constructed. Its performance was investigated by both simulation and experimentation to determine the microdosimetric quantity of “lineal energy”. In the simulation study, lineal energy distribution, mean quality factor and dose-equivalent response of the microdosimeter for eleven neutron energies from 10 keV to 14 MeV, along with the energy spectrum of "2"4"1Am-Be neutrons, were calculated by the Geant4 simulation toolkit. Obtained lineal energy distributions were compatible with the distributions determined by a Rossi counter. Also, the mean quality factors agreed well with the values reported by the ICRU report 40 which confirmed tissue equivalent behavior of the microdosimeter. They were different from the effective quality factor values within 15% between 20 keV and 14 MeV. This led to a flat dose-equivalent response with 20% difference from a median value of 0.82 in the above energy range which was an improvement compared with other THGEM-based detectors, simulating 2 μm of tissue. In spite of the satisfactory determination of the dose-equivalent, the microdosimeter had low detection sensitivity. In the experimental study, the measured lineal energy distribution of "2"4"1Am-Be neutrons was in agreement with the simulated distribution. Further, the measured mean quality factor and dose-equivalent differed by 1.5% and 3.5%, respectively, from the calculated values. Finally, it could be concluded that the investigated microdosimeter reliably determined the desired dose-equivalent value of each neutron field with every energy spectrum lying between 20 keV and

  15. Calculations and measurements of the scintillator-to-water stopping power ratio of liquid scintillators for use in proton radiotherapy

    International Nuclear Information System (INIS)

    Scott Ingram, W.; Robertson, Daniel; Beddar, Sam

    2015-01-01

    Liquid scintillators are a promising detector for high-resolution three-dimensional proton therapy dosimetry. Because the scintillator comprises both the active volume of the detector and the phantom material, an ideal scintillator will exhibit water equivalence in its radiological properties. One of the most fundamental of these is the scintillator’s stopping power. The objective of this study was to compare calculations and measurements of scintillator-to-water stopping power ratios to evaluate the suitability of the liquid scintillators BC-531 and OptiPhase HiSafe 3 for proton dosimetry. We also measured the relative scintillation output of the two scintillators. Both calculations and measurements show that the linear stopping power of OptiPhase is significantly closer to water than that of BC-531. BC-531 has a somewhat higher scintillation output. OptiPhase can be mixed with water at high concentrations, which further improves its scintillator-to-water stopping power ratio. However, this causes the solution to become cloudy, which has a negative impact on the scintillation output and spatial resolution of the detector. OptiPhase is preferred over BC-531 for proton dosimetry because its density and scintillator-to-water stopping power ratio are more water equivalent

  16. Measurement of the ratios of branching fractions and.

    Science.gov (United States)

    Abulencia, A; Acosta, D; Adelman, J; Affolder, T; Akimoto, T; Albrow, M G; Ambrose, D; Amerio, S; Amidei, D; Anastassov, A; Anikeev, K; Annovi, A; Antos, J; Aoki, M; Apollinari, G; Arguin, J-F; Arisawa, T; Artikov, A; Ashmanskas, W; Attal, A; Azfar, F; Azzi-Bacchetta, P; Azzurri, P; Bacchetta, N; Bachacou, H; Badgett, W; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Baroiant, S; Bartsch, V; Bauer, G; Bedeschi, F; Behari, S; Belforte, S; Bellettini, G; Bellinger, J; Belloni, A; Ben-Haim, E; Benjamin, D; Beretvas, A; Beringer, J; Berry, T; Bhatti, A; Binkley, M; Bisello, D; Bishai, M; Blair, R E; Blocker, C; Bloom, K; Blumenfeld, B; Bocci, A; Bodek, A; Boisvert, V; Bolla, G; Bolshov, A; Bortoletto, D; Boudreau, J; Bourov, S; Boveia, A; Brau, B; Bromberg, C; Brubaker, E; Budagov, J; Budd, H S; Budd, S; Burkett, K; Busetto, G; Bussey, P; Byrum, K L; Cabrera, S; Campanelli, M; Campbell, M; Canelli, F; Canepa, A; Carlsmith, D; Carosi, R; Carron, S; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chang, S H; Chapman, J; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, I; Cho, K; Chokheli, D; Chou, J P; Chu, P H; Chuang, S H; Chung, K; Chung, W H; Chung, Y S; Ciljak, M; Ciobanu, C I; Ciocci, M A; Clark, A; Clark, D; Coca, M; Connolly, A; Convery, M E; Conway, J; Cooper, B; Copic, K; Cordelli, M; Cortiana, G; Cruz, A; Cuevas, J; Culbertson, R; Cyr, D; Daronco, S; D'Auria, S; D'onofrio, M; Dagenhart, D; de Barbaro, P; De Cecco, S; Deisher, A; De Lentdecker, G; Dell'Orso, M; Demers, S; Demortier, L; Deng, J; Deninno, M; De Pedis, D; Derwent, P F; Dionisi, C; Dittmann, J; DiTuro, P; Dörr, C; Dominguez, A; Donati, S; Donega, M; Dong, P; Donini, J; Dorigo, T; Dube, S; Ebina, K; Efron, J; Ehlers, J; Erbacher, R; Errede, D; Errede, S; Eusebi, R; Fang, H C; Farrington, S; Fedorko, I; Fedorko, W T; Feild, R G; Feindt, M; Fernandez, J P; Field, R; Flanagan, G; Flores-Castillo, L R; Foland, A; Forrester, S; Foster, G W; Franklin, M; Freeman, J C; Fujii, Y; Furic, I; Gajjar, A; Gallinaro, M; Galyardt, J; Garcia, J E; Sciverez, M Garcia; Garfinkel, A F; Gay, C; Gerberich, H; Gerchtein, E; Gerdes, D; Giagu, S; Giannetti, P; Gibson, A; Gibson, K; Ginsburg, C; Giolo, K; Giordani, M; Giunta, M; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldschmidt, N; Goldstein, J; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Gotra, Y; Goulianos, K; Gresele, A; Griffiths, M; Grinstein, S; Grosso-Pilcher, C; Grundler, U; da Costa, J Guimaraes; Haber, C; Hahn, S R; Hahn, K; Halkiadakis, E; Hamilton, A; Han, B-Y; Handler, R; Happacher, F; Hara, K; Hare, M; Harper, S; Harr, R F; Harris, R M; Hatakeyama, K; Hauser, J; Hays, C; Hayward, H; Heijboer, A; Heinemann, B; Heinrich, J; Hennecke, M; Herndon, M; Heuser, J; Hidas, D; Hill, C S; Hirschbuehl, D; Hocker, A; Holloway, A; Hou, S; Houlden, M; Hsu, S-C; Huffman, B T; Hughes, R E; Huston, J; Ikado, K; Incandela, J; Introzzi, G; Iori, M; Ishizawa, Y; Ivanov, A; Iyutin, B; James, E; Jang, D; Jayatilaka, B; Jeans, D; Jensen, H; Jeon, E J; Jones, M; Joo, K K; Jun, S Y; Junk, T R; Kamon, T; Kang, J; Karagoz-Unel, M; Karchin, P E; Kato, Y; Kemp, Y; Kephart, R; Kerzel, U; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, M S; Kim, S B; Kim, S H; Kim, Y K; Kirby, M; Kirsch, L; Klimenko, S; Klute, M; Knuteson, B; Ko, B R; Kobayashi, H; Kondo, K; Kong, D J; Konigsberg, J; Korytov, A; Kotwal, A V; Kovalev, A; Kraus, J; Kravchenko, I; Kreps, M; Kreymer, A; Kroll, J; Krumnack, N; Kruse, M; Krutelyov, V; Kuhlmann, S E; Kusakabe, Y; Kwang, S; Laasanen, A T; Lai, S; Lami, S; Lami, S; Lammel, S; Lancaster, M; Lander, R L; Lannon, K; Lath, A; Latino, G; Lazzizzera, I; Lecci, C; LeCompte, T; Lee, J; Lee, J; Lee, S W; Lefèvre, R; Leonardo, N; Leone, S; Levy, S; Lewis, J D; Li, K; Lin, C; Lin, C S; Lindgren, M; Lipeles, E; Liss, T M; Lister, A; Litvintsev, D O; Liu, T; Liu, Y; Lockyer, N S; Loginov, A; Loreti, M; Loverre, P; Lu, R-S; Lucchesi, D; Lujan, P; Lukens, P; Lungu, G; Lyons, L; Lys, J; Lysak, R; Lytken, E; Mack, P; MacQueen, D; Madrak, R; Maeshima, K; Maksimovic, P; Manca, G; Margaroli, F; Marginean, R; Marino, C; Martin, A; Martin, M; Martin, V; Martínez, M; Maruyama, T; Matsunaga, H; Mattson, M E; Mazini, R; Mazzanti, P; McFarland, K S; McGivern, D; McIntyre, P; McNamara, P; McNulty, R; Mehta, A; Menzemer, S; Menzione, A; Merkel, P; Mesropian, C; Messina, A; von der Mey, M; Miao, T; Miladinovic, N; Miles, J; Miller, R; Miller, J S; Mills, C; Milnik, M; Miquel, R; Miscetti, S; Mitselmakher, G; Miyamoto, A; Moggi, N; Mohr, B; Moore, R; Morello, M; Fernandez, P Movilla; Mülmenstädt, J; Mukherjee, A; Mulhearn, M; Muller, Th; Mumford, R; Murat, P; Nachtman, J; Nahn, S; Nakano, I; Napier, A; Naumov, D; Necula, V; Neu, C; Neubauer, M S; Nielsen, J; Nigmanov, T; Nodulman, L; Norniella, O; Ogawa, T; Oh, S H; Oh, Y D; Okusawa, T; Oldeman, R; Orava, R; Osterberg, K; Pagliarone, C; Palencia, E; Paoletti, R; Papadimitriou, V; Papikonomou, A; Paramonov, A A; Parks, B; Pashapour, S; Patrick, J; Pauletta, G; Paulini, M; Paus, C; Pellett, D E; Penzo, A; Phillips, T J; Piacentino, G; Piedra, J; Pitts, K; Plager, C; Pondrom, L; Pope, G; Portell, X; Poukhov, O; Pounder, N; Prakoshyn, F; Pronko, A; Proudfoot, J; Ptohos, F; Punzi, G; Pursley, J; Rademacker, J; Rahaman, A; Rakitin, A; Rappoccio, S; Ratnikov, F; Reisert, B; Rekovic, V; van Remortel, N; Renton, P; Rescigno, M; Richter, S; Rimondi, F; Rinnert, K; Ristori, L; Robertson, W J; Robson, A; Rodrigo, T; Rogers, E; Rolli, S; Roser, R; Rossi, M; Rossin, R; Rott, C; Ruiz, A; Russ, J; Rusu, V; Ryan, D; Saarikko, H; Sabik, S; Safonov, A; Sakumoto, W K; Salamanna, G; Salto, O; Saltzberg, D; Sanchez, C; Santi, L; Sarkar, S; Sato, K; Savard, P; Savoy-Navarro, A; Scheidle, T; Schlabach, P; Schmidt, E E; Schmidt, M P; Schmitt, M; Schwarz, T; Scodellaro, L; Scott, A L; Scribano, A; Scuri, F; Sedov, A; Seidel, S; Seiya, Y; Semenov, A; Semeria, F; Sexton-Kennedy, L; Sfiligoi, I; Shapiro, M D; Shears, T; Shepard, P F; Sherman, D; Shimojima, M; Shochet, M; Shon, Y; Shreyber, I; Sidoti, A; Sinervo, P; Sisakyan, A; Sjolin, J; Skiba, A; Slaughter, A J; Sliwa, K; Smirnov, D; Smith, J R; Snider, F D; Snihur, R; Soderberg, M; Soha, A; Somalwar, S; Sorin, V; Spalding, J; Spinella, F; Squillacioti, P; Stanitzki, M; Staveris-Polykalas, A; Denis, R St; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Stuart, D; Suh, J S; Sukhanov, A; Sumorok, K; Sun, H; Suzuki, T; Taffard, A; Tafirout, R; Takashima, R; Takeuchi, Y; Takikawa, K; Tanaka, M; Tanaka, R; Tecchio, M; Teng, P K; Terashi, K; Tether, S; Thom, J; Thompson, A S; Thomson, E; Tipton, P; Tiwari, V; Tkaczyk, S; Toback, D; Tollefson, K; Tomura, T; Tonelli, D; Tönnesmann, M; Torre, S; Torretta, D; Tourneur, S; Trischuk, W; Tsuchiya, R; Tsuno, S; Turini, N; Ukegawa, F; Unverhau, T; Uozumi, S; Usynin, D; Vacavant, L; Vaiciulis, A; Vallecorsa, S; Varganov, A; Vataga, E; Velev, G; Veramendi, G; Veszpremi, V; Vickey, T; Vidal, R; Vila, I; Vilar, R; Vollrath, I; Volobouev, I; Würthwein, F; Wagner, P; Wagner, R G; Wagner, R L; Wagner, W; Wallny, R; Walter, T; Wan, Z; Wang, M J; Wang, S M; Warburton, A; Ward, B; Waschke, S; Waters, D; Watts, T; Weber, M; Wester, W C; Whitehouse, B; Whiteson, D; Wicklund, A B; Wicklund, E; Williams, H H; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, C; Worm, S; Wright, T; Wu, X; Wynne, S M; Yagil, A; Yamamoto, K; Yamaoka, J; Yamashita, Y; Yang, C; Yang, U K; Yao, W M; Yeh, G P; Yoh, J; Yorita, K; Yoshida, T; Yu, I; Yu, S S; Yun, J C; Zanello, L; Zanetti, A; Zaw, I; Zetti, F; Zhang, X; Zhou, J; Zucchelli, S

    2006-05-19

    We report an observation of the decay B(O)(S) --> D(-)(s)pi(+) in pp collisions at radical S = 1.96 TeV using 115 pb(-1) of data collected by the CDF II detector at the Fermilab Tevatron. We observe 83 +/- 11(stat) B(O)(s) --> D(-)(s)pi(+) candidates, representing a large increase in statistics over previous measurements and the first observation of this decay at a pp collider. We present the first measurement of the relative branching fraction Beta(B(O)(s) --> D(-)(s)pi(+))/Beta(B(0) --> D(-)(pi)(+)) = 1.32 +/- 0.18(stat) +/- 0.38(syst). We also measure Beta(B(+) --> D(0)pi(+))/Beta(B(0) -->D(-)pi(+)) = 1.97 +/- 0.10(stat) +/- 0.21(syst), which is consistent with previous measurements.

  17. Measurement of the K+ --> pi+ nu nu branching ratio

    Energy Technology Data Exchange (ETDEWEB)

    Adler, S.; /Brookhaven; Anisimovsky, V.V.; /Moscow, INR; Aoki, M.; /TRIUMF; Ardebili, M.; /Princeton U.; Artamonov, A.V.; /Serpukhov, IHEP; Atiya, M.; /Brookhaven; Bassalleck, B.; /New Mexico U.; Bazarko, A.O.; /Princeton U.; Bhuyan, B.; /Brookhaven; Blackmore, E.W.; /TRIUMF; Bryman, D.A.; /British Columbia U. /Tsinghua U., Beijing /TRIUMF

    2008-03-01

    Experiment E949 at Brookhaven National Laboratory studied the rare decay K{sup +}-->pi{sup +} nu{ovr {nu}} and other processes with an exposure of 1.77 x 10{sup 12} k{sup +}'s. The data were analyzed using a blind analysis technique yielding one candidate event with an estimated background of 0.30 {+-} 0.03 events. Combining this result with the observation of two candidate events by the predecessor experiment E787 gave the branching ratio B(K{sup +}-->pi{sup +} nu{ovr {nu}}) = (1.47{sub -0.89}{sup +1.30}) x 10{sup -10}, consistent with the standard model prediction of (0.74 {+-} 0.20) x 10{sup -10}. This is a more detailed report of results previously published [V.V. Anisimovsky et al., Phys. Rev. Lett. 93, 031801 (2004)].

  18. Ambient dose equivalent measurements in secondary radiation fields at proton therapy facility CCB IFJ PAN in Krakow using recombination chambers

    Directory of Open Access Journals (Sweden)

    Jakubowska Edyta A.

    2016-03-01

    Full Text Available This work presents recombination methods used for secondary radiation measurements at the Facility for Proton Radiotherapy of Eye Cancer at the Institute for Nuclear Physics, IFJ, in Krakow (Poland. The measurements of H*(10 were performed, with REM-2 tissue equivalent chamber in two halls of cyclotrons AIC-144 and Proteus C-235 and in the corridors close to treatment rooms. The measurements were completed by determination of gamma radiation component, using a hydrogen-free recombination chamber. The results were compared with the measurements using rem meter types FHT 762 (WENDI-II and NM2 FHT 192 gamma probe and with stationary dosimetric system.

  19. Diurnal measurement of equilibrium equivalent radon/thoron concentration using time integrated flow mode grab sampler

    International Nuclear Information System (INIS)

    Pant, P.; Kandari, T.; Ramola, R.C.; Semwal, C.P.; Prasad, M.

    2018-01-01

    The basic processes which influenced the concentration of radon and thoron decay products are- attachment, recoil and deposition and by the room specific parameters of radon exhalation and ventilation. The freshly formed decay products have a high diffusivities (especially in air) and ability to stick to surfaces. According to UNSCEAR 1977, radon daughters may be combined as the so called equilibrium equivalent concentration which is related to the potential alpha energy distribution concentration. In the present study an effort has been made to see the diurnal variation of radon and thoron progeny concentration using time integrated flow mode sampler

  20. Measurement equivalence of the CES-D 8 depression-scale among the ageing population in eleven European countries.

    Science.gov (United States)

    Missinne, Sarah; Vandeviver, Christophe; Van de Velde, Sarah; Bracke, Piet

    2014-07-01

    Depression is one of the most prevalent mental disorders in later life. However, despite considerable research attention, great confusion remains regarding the association between ageing and depression. There is doubt as to whether a depression scale performs identically for different age groups and countries. Although measurement equivalence is a crucial prerequisite for valid comparisons across age groups and countries, it has not been established for the eight-item version of the Centre for Epidemiological Studies Depression Scale (CES-D8). Using multi-group confirmatory factor analysis, we assess configural, metric, and scalar measurement equivalence across two age groups (50-64 years of age and 65 or older) in eleven European countries, employing data from the Survey of Health, Ageing, and Retirement (SHARE). Results indicate that the construct of depression is comparable across age and country groups, allowing the substantive interpretation of correlates and mean levels of depressive symptoms. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Method for measuring and evaluation dose equivalent rate from fast neutrons in mixed gamma-neutron fields around particles accelerators

    International Nuclear Information System (INIS)

    Cruceru, I.; Sandu, M.; Cruceru, M.

    1994-01-01

    A method for measuring and evaluation of doses and dose equivalent rate in mixed gamma- neutron fields is discussed in this paper. The method is basedon a double detector system consist of an ionization chamber with components made from a plastic scintillator, coupled to on photomultiplier. Generally the radiation fields around accelerators are complex, often consisting of many different ionizing radiations extending over a broad range of energies. This method solve two major difficulties: determination of response functions of radiation detectors; interpretation of measurement and determination of accuracy. The discrimination gamma-fast neutrons is assured directly without a pulse shape discrimination circuit. The method is applied to mixed fields in which particle energies are situated in the energy range under 20 MeV and an izotropic emision (Φ=10 4 -10 11 n.s -1 ). The dose equivalent rates explored is 0.01mSV--0.1SV

  2. A simplified, improved method for making amplifier equivalent noise charge measurements using a new generation digitizing oscilloscope

    International Nuclear Information System (INIS)

    Zimmerman, T.

    1990-10-01

    Historically a variety of methods have been used to measure the equivalent noise charge (ENC) of amplifier/shaper systems for high energy physics. Some of these methods require several pieces of special test equipment and a fair amount of effort. The advent of digitizing oscilloscopes with statistics capabilities makes it possible to perform certain types of noise measurements accurately with very little effort. This paper describes the noise measurement method of a time invariant amplifier/shaper and of a time variant correlated sampling system, using a Tektronix DSA602 Digitizing Signal Analyzer. 4 figs

  3. Standardization for oxygen isotope ratio measurement - still an unsolved problem.

    Science.gov (United States)

    Kornexl; Werner; Gehre

    1999-07-01

    Numerous organic and inorganic laboratory standards were gathered from nine European and North American laboratories and were analyzed for their delta(18)O values with a new on-line high temperature pyrolysis system that was calibrated using Vienna standard mean ocean water (VSMOW) and standard light Antartic precipitation (SLAP) internationally distributed reference water samples. Especially for organic materials, discrepancies between reported and measured values were high, ranging up to 2 per thousand. The reasons for these discrepancies are discussed and the need for an exact and reliable calibration of existing reference materials, as well as for the establishment of additional organic and inorganic reference materials is stressed. Copyright 1999 John Wiley & Sons, Ltd.

  4. Installation with magnetic suspension of test bodies for measurement of small forces. Verification of equivalence of inertial and gravitational mass

    International Nuclear Information System (INIS)

    Kalebin, S.M.

    1988-01-01

    Torsion installation with magnetic suspension of test bodies for detection of small forces is considered. Installation application for verification of equivalence of inertial and gravitational mass in the case of test body incidence on the Earth (Etvesh experiment) and in the case of their incidene on the Sun (Dicke experiment) is discussed. The total mass of test bodies, produced in the form of cylinders with 3 cm radius, equals 50 kg (one lead body and one copper body); beam radius of test bodies equals 3 cm (the cylinders are tight against one another); ferrite cylinder with 3 cm radius and 10 cm height is used for their suspension in magnetic field. Effect of thermal noise and electromagnetic force disturbances on measurement results is considered. Conducted calculations show that suggested installation enables to improve the accuracy of verifying mentioned equivalence at least by one order and upwards. This suggests that such installation is a matter of interest for experiments on small force detection

  5. Measurement of dose equivalent distribution on-board commercial jet aircraft

    International Nuclear Information System (INIS)

    Kubancak, J.; Ambrozova, I.; Ploc, O.; Pachnerova Brabcova, K.; Stepan, V.; Uchihori, Y.

    2014-01-01

    The annual effective doses of aircrew members often exceed the limit of 1 mSv for the public due to the increased level of cosmic radiation at the flight altitudes, and thus, it is recommended to monitor them [International Commission on Radiation Protection. 1990 Recommendations of the International Commission on Radiological Protection. ICRP Publication 60. Ann. ICRP 21(1-3), (1991)]. According to the Monte Carlo simulations [Battistoni, G., Ferrari, A., Pelliccioni, M. and Villari, R. Evaluation of the doses to aircrew members taking into consideration the aircraft structures. Adv. Space Res. 36, 1645-1652 (2005) and Ferrari, A., Pelliccioni, M. and Villari, R. Evaluation of the influence of aircraft shielding on the aircrew exposure through an aircraft mathematical model. Radiat. Prot. Dosim. 108(2), 91-105 (2004)], the ambient dose equivalent rate H*(10) depends on the location in the aircraft. The aim of this article is to experimentally evaluate H*(10) on-board selected types of aircraft. The authors found that H*(10) values are higher in the front and the back of the cabin and lesser in the middle of the cabin. Moreover, total dosimetry characteristics obtained in this way are in a reasonable agreement with other data, in particular with the above-mentioned simulations. (authors)

  6. Comparison between the calculated and measured dose distributions for four beams of 6 MeV linac in a human-equivalent phantom

    Directory of Open Access Journals (Sweden)

    Reda Sonia M.

    2006-01-01

    Full Text Available Radiation dose distributions in various parts of the body are of importance in radiotherapy. Also, the percent depth dose at different body depths is an important parameter in radiation therapy applications. Monte Carlo simulation techniques are the most accurate methods for such purposes. Monte Carlo computer calculations of photon spectra and the dose ratios at surfaces and in some internal organs of a human equivalent phantom were performed. In the present paper, dose distributions in different organs during bladder radiotherapy by 6 MeV X-rays were measured using thermoluminescence dosimetry placed at different points in the human-phantom. The phantom was irradiated in exactly the same manner as in actual bladder radiotherapy. Four treatment fields were considered to maximize the dose at the center of the target and minimize it at non-target healthy organs. All experimental setup information was fed to the MCNP-4b code to calculate dose distributions at selected points inside the proposed phantom. Percent depth dose distribution was performed. Also, the absorbed dose as ratios relative to the original beam in the surrounding organs was calculated by MCNP-4b and measured by thermoluminescence dosimetry. Both measured and calculated data were compared. Results indicate good agreement between calculated and measured data inside the phantom. Comparison between MCNP-4b calculations and measurements of depth dose distribution indicated good agreement between both.

  7. [Comparison study on subjective and objective measurements of the accommodative convergence to accommodation ratio].

    Science.gov (United States)

    Xu, Jing-jing; Xu, Dan; Huang, Tao; Jiang, Jian; Lü, Fan

    2012-05-01

    To detect the accommodative convergence to accommodation (AC/A) ratios measured respectively by objective and subjective methods. The differences and its relative factors were explored. Forty young volunteers were measured by eye tracker to get the amount of convergence when fixating at the target at 100 cm, 50 cm, 33 cm and 25 cm and were measured by infrared auto-refractor to get corresponding accommodative responses. AC/A ratio based on these two measurements were compared with the calculated and the gradient AC/A ratio from Von Graefe tests. Mean value of stimulated AC/A ratio measured by eye tracker was higher than the calculated and gradient AC/A ratio by Von Graefe method (P = 0.003, 0.001). There are statistic correlation (r = 0.871, P = 0.000) and difference (P = 0.000) between stimulated AC/A ratio and response AC/A ratios both measured by eye tracker, and the difference trends to be greater with the higher AC/A ratio. The objective AC/A ratio is usually higher than the clinical subjective measurement because of more proximal effect. The response AC/A ratio measured objectively may reveal realistically the mutual effect and relationship between accommodation and convergence and it seems to be more credible to be the monitor parameter on progression of myopia in clinics.

  8. Equivalent risky allocation: The new ERA of risk measurement for heterogeneous investors

    NARCIS (Netherlands)

    Plunus, S.; Gillet, R.; Hübner, G.M.B.J.

    2015-01-01

    This paper introduces an investor-specific risk measure derived from the linear-exponential (linex) utility function. It combines the notions of risk perception and risk aversion. To make this measure interpretable and comparable with others like variance or value-at-risk, it is translated into an

  9. Measurement Equivalence in ADL and IADL Difficulty Across International Surveys of Aging: Findings From the HRS, SHARE, and ELSA

    Science.gov (United States)

    Kasper, Judith D.; Brandt, Jason; Pezzin, Liliana E.

    2012-01-01

    Objective. To examine the measurement equivalence of items on disability across three international surveys of aging. Method. Data for persons aged 65 and older were drawn from the Health and Retirement Survey (HRS, n = 10,905), English Longitudinal Study of Aging (ELSA, n = 5,437), and Survey of Health, Ageing and Retirement in Europe (SHARE, n = 13,408). Differential item functioning (DIF) was assessed using item response theory (IRT) methods for activities of daily living (ADL) and instrumental activities of daily living (IADL) items. Results. HRS and SHARE exhibited measurement equivalence, but 6 of 11 items in ELSA demonstrated meaningful DIF. At the scale level, this item-level DIF affected scores reflecting greater disability. IRT methods also spread out score distributions and shifted scores higher (toward greater disability). Results for mean disability differences by demographic characteristics, using original and DIF-adjusted scores, were the same overall but differed for some subgroup comparisons involving ELSA. Discussion. Testing and adjusting for DIF is one means of minimizing measurement error in cross-national survey comparisons. IRT methods were used to evaluate potential measurement bias in disability comparisons across three international surveys of aging. The analysis also suggested DIF was mitigated for scales including both ADL and IADL and that summary indexes (counts of limitations) likely underestimate mean disability in these international populations. PMID:22156662

  10. EPA scientists develop Federal Reference & Equivalent Methods for measuring key air pollutants

    Science.gov (United States)

    EPA operates a nationwide air monitoring network to measure six primary air pollutants: carbon monoxide, lead, sulfur dioxide, ozone, nitrogen dioxide, and particulate matter as part of its mission to protect human health and the environment.

  11. Conjugacy, orbit equivalence and classification of measure-preserving group actions

    DEFF Research Database (Denmark)

    Törnquist, Asger Dag

    2009-01-01

    We prove that if G is a countable discrete group with property (T) over an infinite subgroup HG which contains an infinite Abelian subgroup or is normal, then G has continuum-many orbit-inequivalent measure-preserving almost-everywhere-free ergodic actions on a standard Borel probability space...... and Weiss for conjugacy of measure-preserving ergodic almost-everywhere-free actions of discrete countable groups....

  12. The intercomparison of 137Cs irradiator output measurement and personal dose equivalent, Hp(10), using TLD and film

    International Nuclear Information System (INIS)

    Nazaroh; Susetyo Trijoko; Sri Inang Sunaryati

    2010-01-01

    Intercomparison of output measurement of 137 Cs irradiator and personal dose equivalent, Hp(10) using TLD and film have been carried out in the year of 2006 to 2008. According to IAEA recommendation, intercomparison is one of audit activities but it is performed in the spirit of collaboration and support rather than in the spirit of inspection. The aim of intercomparison of output measurement of 137 Cs irradiator is to verify the dose stated by the participant laboratories. Intercomparison is also to assess the competency of the participant, to keep traceability and consistency of measurement result, to assure that instrument work correctly and the result of evaluation was in agreement, and also for fulfilling one of the clauses of ISO-17025-2005. Besides that, this intercomparison aimed to facilitate link between the system and members of national measurement and transfer of experience in measurement technique and dose evaluation of radiation. The benefit of intercomparison is important among others as tests of proficiency in dose evaluation or measurement, upgrading quality of service and for obeying supervisor body legislation (BAPETEN). TLD was used as a means of output 137 Cs irradiator measurement, whereas film and TLD were used for dose intercomparison. This paper presented result of intercomparison of output measurement and evaluation of personal dose equivalent, Hp(10) in the year of 2006 to 2008 followed by 6 participants: Balai Pengamanan Fasilitas Kesehatan (BPFK) Jakarta, Medan, Surabaya, Makasar, PTLR and Laboratory of Keselamatan dan Kesehatan Lingkungan (KKL)-PTKMR BATAN. In this intercomparison, the dose of TLD stated by participant were compared with the dose measured by Radiation Metrology Laboratory (LMR), and the results showed the differences were within 10 %, so it was satisfied. The results of intercomparison of personal dose equivalent, Hp(10) were evaluated based on ISO/IEC Guide 43-1, 1997 analysis and expressed as E n . The values of E n

  13. Stable isotope ratio measurements in hydrogen, nitrogen, and oxygen using Raman scattering

    International Nuclear Information System (INIS)

    Harney, R.C.; Bloom, S.D.; Milanovich, F.P.

    1975-01-01

    A method for measuring stable isotope ratios using laser Raman scattering was developed which may prove of significant utility and benefit in stable isotope tracer studies. Crude isotope ratio measurements obtained with a low-power laser indicate that with current technology it should be possible to construct an isotope ratio measurement system using laser Raman scattering that is capable of performing 0.1 percent accuracy isotope ratio measurements of 16 O/ 18 O in natural abundance oxygen gas or 14 N/ 15 N in natural abundance nitrogen gas in times less than two minutes per sample. Theory pertinent to the technique, designs of specific isotope ratio spectrometer systems, and data relating to isotope ratio measurements in hydrogen, nitrogen, and oxygen are presented. In addition, the current status of several studies utilizing this technique is discussed. (auth)

  14. Development, optimisation, and application of ICP-SFMS methods for the measurement of isotope ratios

    International Nuclear Information System (INIS)

    Stuerup, S.

    2000-07-01

    The measurement of isotopic composition and isotope ratios in biological and environmental samples requires sensitive, precise, and accurate analytical techniques. The analytical techniques used are traditionally based on mass spectrometry, among these techniques is the ICP-SFMS technique, which became commercially available in the mid 1990s. This technique is characterised by high sensitivity, low background, and the ability to separate analyte signals from spectral interferences. These features are beneficial for the measurement of isotope ratios and enable the measurement of isotope ratios of elements, which it has not previously been possible to measure due to either spectral interferences or poor sensitivity. The overall purpose of the project was to investigate the potential of the single detector ICP-SFMS technique for the measurement of isotope ratios in biological and environmental samples. One part of the work has focused on the fundamental aspects of the ICP-SFMS technique with special emphasize on the features important to the measurement of isotope ratios, while another part has focused on the development, optimisation and application of specific methods for the measurement of isotope ratios of elements of nutritional interest and radionuclides. The fundamental aspects of the ICP-SFMS technique were investigated theoretically and experimentally by the measurement of isotope ratios applying different experimental conditions. It was demonstrated that isotope ratios could be measured reliably using ICP-SFMS by educated choice of acquisition parameters, scanning mode, mass discrimination correction, and by eliminating the influence of detector dead time. Applying the knowledge gained through the fundamental study, ICP-SFMS methods for the measurement of isotope ratios of calcium, zinc, molybdenum and iron in human samples and a method for the measurement of plutonium isotope ratios and ultratrace levels of plutonium and neptunium in environmental samples

  15. Measurement equivalence of the food related lifestyle instrument (FRL) in Ireland and Great Britain

    DEFF Research Database (Denmark)

    O´Sullivan, C.; Scholderer, Joachim; Cowan, Cathal

    2005-01-01

    The food-related lifestyle instrument (FRL) is tested for cross-cultural validity. Representative consumer samples from the UK 1998 ( N = 1000) and Ireland 2001 (N = 1024) are compared using multi-sample confirmatory factor analysis with structured means. The results suggest that, in all five FRL...... domains, the measurement characteristics of the survey instrument were completely invariant across the two cultures. No indication was found of any bias. Regarding future applications of the FRL, it can be concluded that the instrument has identical measurement characteristics when applied to consumer...

  16. Rotor equivalent wind speed for power curve measurement – comparative exercise for IEA Wind Annex 32

    DEFF Research Database (Denmark)

    Wagner, Rozenn; Cañadillas, B.; Clifton, A.

    2014-01-01

    was the definition of the segment area used as weighting for the wind speeds measured at the various heights in the calculation of the REWS. This comparative exercise showed that the REWS method results in a significant difference compared to the standard method using the wind speed at hub height in conditions...

  17. Measurement Equivalence of the Autism Symptom Phenotype in Children and Youth

    Science.gov (United States)

    Duku, Eric; Szatmari, Peter; Vaillancourt, Tracy; Georgiades, Stelios; Thompson, Ann; Liu, Xiao-Qing; Paterson, Andrew D.; Bennett, Terry

    2013-01-01

    Background: The Autism Diagnostic Interview-Revised (ADI-R) is a gold standard assessment of Autism Spectrum Disorder (ASD) symptoms and behaviours. A key underlying assumption of studies using the ADI-R is that it measures the same phenotypic constructs across different populations (i.e. males/females, younger/older, verbal/nonverbal). The…

  18. The prospect for fuel ion ratio measurements in ITER by collective Thomson scattering

    DEFF Research Database (Denmark)

    Stejner Pedersen, Morten; Korsholm, Søren Bang; Nielsen, Stefan Kragh

    2012-01-01

    We show that collective Thomson scattering (CTS) holds the potential to become a new diagnostic principle for measurements of the fuel ion ratio, nT/nD, in ITER. Fuel ion ratio measurements will be important for plasma control and machine protection in ITER. Measurements of ion cyclotron structures...... in CTS spectra have been suggested as the basis for a new fuel ion ratio diagnostic which would be well suited for reactor environments and capable of providing spatially resolved measurements in the plasma core. Such measurements were demonstrated in recent experiments in the TEXTOR tokamak. Here we...... conduct a sensitivity study to investigate the potential measurement accuracy of a CTS fuel ion ratio diagnostic on ITER. The study identifies regions of parameter space in which CTS can be expected to provide useful information on plasma composition, and we find that a CTS fuel ion ratio diagnostic could...

  19. The equidosemeter ED-02 as a device for dose equivalent measurements in mixed neutron and photon radiation fields

    International Nuclear Information System (INIS)

    Abrosimov, A.I.; Alekseev, A.G.; Antipov, V.A.; Golovachik, V.T.

    1985-01-01

    The equidosemeter ED-02 is to be used for simultaneous measurements of the dose equivalent, absorbed dose, and mean quality factor of mixed radiations. The detector is a tissue equivalent spherical low-pressure proportional counter tube the signal of which is simultaneously recorded in two channels - a current channel and a pulse one. The current channel is linear and its response proportional to the absorbed dose. The pulse channel includes a nonlinear pulse amplitude converter the characteristic of which, taking into account the required dependence of the mean quality factor on linear energy transfer, has been chosen in such a way that in final counting the pulse channel response is proportional to the difference between dose equivalent and absorbed dose. On the basis of calculations of event spectra in the sensitive volume of the detector, the energy dependence of the dosemeter sensitivity is analysed for neutron energies up to 20 MeV. The characteristic of the nonlinear converter has been calculated on the basis of the construction parameters of the detector and optimized with respect to a representative sample of neutron spectra beyond the shields of nuclear plants. The heterogeneity of the detector, i.e. the difference between the atomic composition of wall and filling and the composition of soft biological tissue as well as the effect of the conducting coating of the case cathode, has been taken into consideration. Moreover, the test results of the device in mixed neutron-photon fields of 60 Co, 239 Pu-α-Be and 252 Cf radioisotope sources are presented. The main measuring error of dose characteristics is shown to be less than 20% in the dose range 1 x 10 -3 to 4 x 10 -3 Sv/h. (author)

  20. Water-equivalent one-dimensional scintillating fiber-optic dosimeter for measuring therapeutic photon beam

    International Nuclear Information System (INIS)

    Moon, Jinsoo; Won Jang, Kyoung; Jae Yoo, Wook; Han, Ki-Tek; Park, Jang-Yeon; Lee, Bongsoo

    2012-01-01

    In this study, we fabricated a one-dimensional scintillating fiber-optic dosimeter, which consists of 9 scintillating fiber-optic dosimeters, septa, and PMMA blocks for measuring surface and percentage depth doses of a therapeutic photon beam. Each dosimeter embedded in the 1-D scintillating fiber-optic dosimeter is composed of square type organic scintillators and plastic optical fibers. Also black PVC films are used as septa to minimize cross-talk between the scintillating fiber-optic dosimeters. To construct a dosimeter system, a 1-D scintillating fiber-optic dosimeter and a CMOS image sensor were combined with 20 m-length plastic optical fibers. Using the dosimeter system, we measured surface and percentage depth doses of 6 and 15 MV photon beams and compared the results with those of EBT films and an ionization chamber. - Highlights: ► Fabrication of a one-dimensional scintillating fiber-optic dosimeter. ► The one-dimensional scintillating fiber-optic dosimeter has 9 scintillating fiber-optic dosimeters. ► Measurements of surface and percentage depth doses of a therapeutic photon beam. ► The results were compared with those of EBT films and an ionization chamber.

  1. Simultaneous measurement of quantum yield ratio and absorption ratio between acceptor and donor by linearly unmixing excitation-emission spectra.

    Science.gov (United States)

    Zhang, C; Lin, F; DU, M; Qu, W; Mai, Z; Qu, J; Chen, T

    2018-02-13

    Quantum yield ratio (Q A /Q D ) and absorption ratio (K A /K D ) in all excitation wavelengths used between acceptor and donor are indispensable to quantitative fluorescence resonance energy transfer (FRET) measurement based on linearly unmixing excitation-emission spectra (ExEm-spFRET). We here describe an approach to simultaneously measure Q A /Q D and K A /K D values by linearly unmixing the excitation-emission spectra of at least two different donor-acceptor tandem constructs with unknown FRET efficiency. To measure the Q A /Q D and K A /K D values of Venus (V) to Cerulean (C), we used a wide-field fluorescence microscope to image living HepG2 cells separately expressing each of four different C-V tandem constructs at different emission wavelengths with 435 nm and 470 nm excitation respectively to obtain the corresponding excitation-emission spectrum (S DA ). Every S DA was linearly unmixed into the contributions (weights) of three excitation-emission spectra of donor (W D ) and acceptor (W A ) as well as donor-acceptor sensitisation (W S ). Plot of W S /W D versus W A /W D for the four C-V plasmids from at least 40 cells indicated a linear relationship with 1.865 of absolute intercept (Q A /Q D ) and 0.273 of the reciprocal of slope (K A /K D ), which was validated by quantitative FRET measurements adopting 1.865 of Q A /Q D and 0.273 of K A /K D for C32V, C5V, CVC and VCV constructs respectively in living HepG2 cells. © 2018 The Authors Journal of Microscopy © 2018 Royal Microscopical Society.

  2. Measurement of the anisotropy ratios in MgB2 single crystals

    International Nuclear Information System (INIS)

    Kim, Heon-Jung; Kang, Byeongwon; Lee, Hyun-Sook; Lee, Sung-Ik

    2006-01-01

    We present our recent measurements on the anisotropy ratios of MgB 2 single crystals. Our measurements indicate that the anisotropy ratios of the penetration depth and of the upper critical field have different magnitudes and temperature dependences, as predicted by theoretical calculations. These results imply that the two-gap nature can strongly influence the superconducting properties of MgB 2

  3. An Analytical Model of Leakage Neutron Equivalent Dose for Passively-Scattered Proton Radiotherapy and Validation with Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, Christopher; Newhauser, Wayne, E-mail: newhauser@lsu.edu [Department of Physics and Astronomy, Louisiana State University and Agricultural and Mechanical College, 202 Nicholson Hall, Baton Rouge, LA 70803 (United States); Mary Bird Perkins Cancer Center, 4950 Essen Lane, Baton Rouge, LA 70809 (United States); Farah, Jad [Institut de Radioprotection et de Sûreté Nucléaire, Service de Dosimétrie Externe, BP-17, 92262 Fontenay-aux-Roses (France)

    2015-05-18

    Exposure to stray neutrons increases the risk of second cancer development after proton therapy. Previously reported analytical models of this exposure were difficult to configure and had not been investigated below 100 MeV proton energy. The purposes of this study were to test an analytical model of neutron equivalent dose per therapeutic absorbed dose (H/D) at 75 MeV and to improve the model by reducing the number of configuration parameters and making it continuous in proton energy from 100 to 250 MeV. To develop the analytical model, we used previously published H/D values in water from Monte Carlo simulations of a general-purpose beamline for proton energies from 100 to 250 MeV. We also configured and tested the model on in-air neutron equivalent doses measured for a 75 MeV ocular beamline. Predicted H/D values from the analytical model and Monte Carlo agreed well from 100 to 250 MeV (10% average difference). Predicted H/D values from the analytical model also agreed well with measurements at 75 MeV (15% average difference). The results indicate that analytical models can give fast, reliable calculations of neutron exposure after proton therapy. This ability is absent in treatment planning systems but vital to second cancer risk estimation.

  4. An Analytical Model of Leakage Neutron Equivalent Dose for Passively-Scattered Proton Radiotherapy and Validation with Measurements

    International Nuclear Information System (INIS)

    Schneider, Christopher; Newhauser, Wayne; Farah, Jad

    2015-01-01

    Exposure to stray neutrons increases the risk of second cancer development after proton therapy. Previously reported analytical models of this exposure were difficult to configure and had not been investigated below 100 MeV proton energy. The purposes of this study were to test an analytical model of neutron equivalent dose per therapeutic absorbed dose (H/D) at 75 MeV and to improve the model by reducing the number of configuration parameters and making it continuous in proton energy from 100 to 250 MeV. To develop the analytical model, we used previously published H/D values in water from Monte Carlo simulations of a general-purpose beamline for proton energies from 100 to 250 MeV. We also configured and tested the model on in-air neutron equivalent doses measured for a 75 MeV ocular beamline. Predicted H/D values from the analytical model and Monte Carlo agreed well from 100 to 250 MeV (10% average difference). Predicted H/D values from the analytical model also agreed well with measurements at 75 MeV (15% average difference). The results indicate that analytical models can give fast, reliable calculations of neutron exposure after proton therapy. This ability is absent in treatment planning systems but vital to second cancer risk estimation

  5. An analytical model of leakage neutron equivalent dose for passively-scattered proton radiotherapy and validation with measurements.

    Science.gov (United States)

    Schneider, Christopher; Newhauser, Wayne; Farah, Jad

    2015-05-18

    Exposure to stray neutrons increases the risk of second cancer development after proton therapy. Previously reported analytical models of this exposure were difficult to configure and had not been investigated below 100 MeV proton energy. The purposes of this study were to test an analytical model of neutron equivalent dose per therapeutic absorbed dose  at 75 MeV and to improve the model by reducing the number of configuration parameters and making it continuous in proton energy from 100 to 250 MeV. To develop the analytical model, we used previously published H/D values in water from Monte Carlo simulations of a general-purpose beamline for proton energies from 100 to 250 MeV. We also configured and tested the model on in-air neutron equivalent doses measured for a 75 MeV ocular beamline. Predicted H/D values from the analytical model and Monte Carlo agreed well from 100 to 250 MeV (10% average difference). Predicted H/D values from the analytical model also agreed well with measurements at 75 MeV (15% average difference). The results indicate that analytical models can give fast, reliable calculations of neutron exposure after proton therapy. This ability is absent in treatment planning systems but vital to second cancer risk estimation.

  6. The new remcounter LB6411: Measurement of neutron ambient dose equivalent H*(10) according to ICRP60 with high sensitivity

    International Nuclear Information System (INIS)

    Klett, A.; Burgkhardt, B.

    1996-01-01

    Since the International Commission on Radiological Protection has issued in publication ICRP60 new recommendations on radiation protection quantities, in neutron monitoring there is now increasing Interest in commercially available instruments optimized and calibrated for the measurement of ambient dose equivalent H*(10). Therefore within a joint cooperation between the Research Center Karlsruhe and EG ampersand G Berthold the neutron-dose-rate meter LB6411 was newly developed. The detector system with integrated electronics has a 3 He proportional counter tube centered in a moderating sphere. The response between thermal energies and 20 MeV was optimized with the help of extensive MCNP Monte-Carlo calculations. The instrument has extremely high sensitivity of approximately 3 counts per nSv and can be used both as a portable or as a stationary neutron monitor. Fluence responses and angular dependencies had been measured in monoenergetic neutron beams provided by the Physikalisch-Technische Bundesanstalt (PTB) in Braunschweig, Germany. The ambient dose equivalent response of the LB6411 is reported over the whole energy range

  7. Equivalent Lagrangians

    International Nuclear Information System (INIS)

    Hojman, S.

    1982-01-01

    We present a review of the inverse problem of the Calculus of Variations, emphasizing the ambiguities which appear due to the existence of equivalent Lagrangians for a given classical system. In particular, we analyze the properties of equivalent Lagrangians in the multidimensional case, we study the conditions for the existence of a variational principle for (second as well as first order) equations of motion and their solutions, we consider the inverse problem of the Calculus of Variations for singular systems, we state the ambiguities which emerge in the relationship between symmetries and conserved quantities in the case of equivalent Lagrangians, we discuss the problems which appear in trying to quantize classical systems which have different equivalent Lagrangians, we describe the situation which arises in the study of equivalent Lagrangians in field theory and finally, we present some unsolved problems and discussion topics related to the content of this article. (author)

  8. Measurement of conversion coefficients between air Kerma and personal dose equivalent and backscatter factors for diagnostic X-ray beams

    International Nuclear Information System (INIS)

    Rosado, Paulo Henrique Goncalves

    2008-01-01

    Two sets of quantities are import in radiological protection: the protection and operational quantities. Both sets can be related to basic physical quantities such as kerma through conversion coefficients. For diagnostic x-ray beams the conversion coefficients and backscatter factors have not been determined yet, those parameters are need for calibrating dosimeters that will be used to determine the personal dose equivalent or the entrance skin dose. Conversion coefficients between air kerma and personal dose equivalent and backscatter factors were experimentally determined for the diagnostic x-ray qualities RQR and RQA recommended by the International Electrotechnical Commission (IEC). The air kerma in the phantom and the mean energy of the spectrum were measured for such purpose. Harshaw LiF-100H thermoluminescent dosemeters (TLD) were used for measurements after being calibrated against an 180 cm 3 Radcal Corporation ionization chamber traceable to a reference laboratory. A 300 mm x 300 mm x 150 mm polymethylmethacrylate (PMMA) slab phantom was used for deep-dose measurements. Tl dosemeters were placed in the central axis of the x-ray beam at 5, 10, 15, 25 and 35 mm depth in the phantom upstream the beam direction Another required parameter for determining the conversion coefficients from was the mean energy of the x-ray spectrum. The spectroscopy of x-ray beams was done with a CdTe semiconductor detector that was calibrated with 133 Ba, 241 Am and 57 Co radiation sources. Measurements of the x-ray spectra were carried out for all RQR and RQA IEC qualities. Corrections due to the detector intrinsic efficiency, total energy absorption, escape fraction of the characteristic x-rays, Compton effect and attenuation in the detector were done aiming an the accurate determination of the mean energy. Measured x-ray spectra were corrected with the stripping method by using these response functions. The typical combined standard uncertainties of conversion coefficients and

  9. Radiographic measurement of the cardiothoracic ratio in pet macaques from Sulawesi, Indonesia

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, Michael A. [Department of Social Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, Ontario M1C 1A4 (Canada)], E-mail: schillaci@utsc.utoronto.ca; Parish, Stephanie [Department of Social Sciences, University of Toronto Scarborough, 1265 Military Trail, Toronto, Ontario M1C 1A4 (Canada); Jones-Engel, Lisa [National Primate Research Center, University of Washington, 1705 N.E. Pacific Street, Seattle, WA 98195 (United States)

    2009-11-15

    The relative size of the heart, as measured by the cardiothoracic ratio, is often used as an index of ventricular hypertrophy-an important measure of myocardial pathophysiology in human primates. Despite its widespread use in human medicine, use of the cardiothoracic ratio in nonhuman primate veterinary medicine has been poorly documented. This report describes the results of our radiographic study of the cardiothoracic ratio in a sample of pet monkeys from Sulawesi, Indonesia. We assessed the effects of age and sex on cardiothoracic ratios, and compared our estimates with those presented in the literature for the Formosan macaque (Macaca cyclopis). Our results indicated a significant difference between the Sulawesi macaque species groupings in cardiothoracic ratios. Sex and age-related differences were not significant. Comparisons of cardiothoracic ratios with published ratios indicated similarity between M. cyclopis and Macaca nigra, but not between M. cyclopis and Macaca tonkeana.

  10. Radiographic measurement of the cardiothoracic ratio in pet macaques from Sulawesi, Indonesia

    International Nuclear Information System (INIS)

    Schillaci, Michael A.; Parish, Stephanie; Jones-Engel, Lisa

    2009-01-01

    The relative size of the heart, as measured by the cardiothoracic ratio, is often used as an index of ventricular hypertrophy-an important measure of myocardial pathophysiology in human primates. Despite its widespread use in human medicine, use of the cardiothoracic ratio in nonhuman primate veterinary medicine has been poorly documented. This report describes the results of our radiographic study of the cardiothoracic ratio in a sample of pet monkeys from Sulawesi, Indonesia. We assessed the effects of age and sex on cardiothoracic ratios, and compared our estimates with those presented in the literature for the Formosan macaque (Macaca cyclopis). Our results indicated a significant difference between the Sulawesi macaque species groupings in cardiothoracic ratios. Sex and age-related differences were not significant. Comparisons of cardiothoracic ratios with published ratios indicated similarity between M. cyclopis and Macaca nigra, but not between M. cyclopis and Macaca tonkeana.

  11. Fermat's principle and the formal equivalence of local light-ray rotation and refraction at the interface between homogeneous media with a complex refractive index ratio.

    Science.gov (United States)

    Sundar, Bhuvanesh; Hamilton, Alasdair C; Courtial, Johannes

    2009-02-01

    We derive a formal description of local light-ray rotation in terms of complex refractive indices. We show that Fermat's principle holds, and we derive an extended Snell's law. The change in the angle of a light ray with respect to the normal of a refractive index interface is described by the modulus of the refractive index ratio; the rotation around the interface normal is described by the argument of the refractive index ratio.

  12. Investigations into the Impact of the Equivalence Ratio on Turbulent Premixed Combustion Using Particle Image Velocimetry and Large Eddy Simulation Techniques: “V” and “M” Flame Configurations in a Swirl Combustor

    KAUST Repository

    Kewlani, Gaurav

    2016-03-24

    Turbulent premixed combustion is studied using experiments and numerical simulations in an acoustically uncoupled cylindrical sudden-expansion swirl combustor, and the impact of the equivalence ratio on the flame–flow characteristics is analyzed. In order to numerically capture the inherent unsteadiness exhibited in the flow, the large eddy simulation (LES) technique based on the artificial flame thickening combustion model is employed. The experimental data are obtained using particle image velocimetry. It is observed that changes in heat loading, in the presence of wall confinement, significantly influence the flow field in the wake region, the stabilization location of the flame, and the flame intensity. Specifically, increasing the equivalence ratio drastically reduces the average inner recirculation zone size and causes transition of the flame macrostructure from the “V” configuration to the “M” configuration. In other words, while the flame stabilizes along the inner shear layer for the V flame, a persistent diffuse reaction zone is also manifested along the outer shear layer for the M flame. The average chemiluminescence intensity increases in the case of the M flame macrostructure, while the axial span of the reaction zone within the combustion chamber decreases. The predictions of the numerical approach resemble the experimental observations, suggesting that the LES framework can be an effective tool for examining the effect of heat loading on flame–flow interactions and the mechanism of transition of the flame macrostructure with a corresponding change in the equivalence ratio.

  13. The Historical Loss Scale: Longitudinal measurement equivalence and prospective links to anxiety among North American indigenous adolescents.

    Science.gov (United States)

    Armenta, Brian E; Whitbeck, Les B; Habecker, Patrick N

    2016-01-01

    Thoughts of historical loss (i.e., the loss of culture, land, and people as a result of colonization) are conceptualized as a contributor to the contemporary distress experienced by North American Indigenous populations. Although discussions of historical loss and related constructs (e.g., historical trauma) are widespread within the Indigenous literature, empirical efforts to understand the consequence of historical loss are limited, partially because of the lack of valid assessments. In this study we evaluated the longitudinal measurement properties of the Historical Loss Scale (HLS)-a standardized measure that was developed to systematically examine the frequency with which Indigenous individuals think about historical loss-among a sample of North American Indigenous adolescents. We also test the hypothesis that thoughts of historical loss can be psychologically distressing. Via face-to-face interviews, 636 Indigenous adolescents from a single cultural group completed the HLS and a measure of anxiety at 4 time-points, which were separated by 1- to 2-year intervals (Mage = 12.09 years, SD = .86, 50.0% girls at baseline). Responses to the HLS were explained well by 3-factor (i.e., cultural loss, loss of people, and cultural mistreatment) and second-order factor structures. Both of these factor structures held full longitudinal metric (i.e., factor loadings) and scalar (i.e., intercepts) equivalence. In addition, using the second-order factor structure, more frequent thoughts of historical loss were associated with increased anxiety. The identified 3-factor and second-order HLS structures held full longitudinal measurement equivalence. Moreover, as predicted, our results suggest that historical loss can be psychologically distressing for Indigenous adolescents. (c) 2016 APA, all rights reserved).

  14. Present status of ambient dose equivalent rate and radioactive substance concentration measurements in working environment. (3) Measuring instruments for ionizing radiation in working environments

    International Nuclear Information System (INIS)

    Matsubara, Shohei

    2006-01-01

    In order to measure the airborne radioactive substance concentration in working environments, some kinds of sampler such as dust sampler and iodine sampler, measuring instruments (alpha and beta spectrometer, and liquid scintillation counter), monitor (dust-, iodine- and gas-monitor), survey meter for measuring gamma ray dose rate are stated. The measurement method of α, β and γ-ray nuclides and ambient dose-equivalent at 10 mm was explained. Some examples of the list of dust sampler, filter, tritium sampler, dust monitor, iodine monitor, gas monitor, and survey meter on the market are shown. There are so many kinds of measuring instruments for ionizing radiation in working environment that the best instrument for measurement should be selected. The environment conditions such as sample form, temperature and humidity have to be considered in order to evaluate the measurement values. (S.Y.)

  15. Measurement of the charge ratio of atmospheric muons with the CMS detector

    CERN Document Server

    AUTHOR|(CDS)2070976

    2010-01-01

    5 GeV/c to 1 TeV/c. The surface flux ratio is measured to be 1.2766 $\\pm$ 0.0032 (stat.) $\\pm$ 0.0032 (syst.), independent of the muon momentum, below 100 GeV/c. This is the most precise measurement to date. At higher momenta the data are consistent with an increase of the charge ratio, in agreement with cosmic-ray shower models and compatible with previous measurements by deep-underground experiments.

  16. WIPP WAC Equivalence Support Measurements for Low-Level Sludge Waste at Los Alamos National Laboratory - 12242

    Energy Technology Data Exchange (ETDEWEB)

    Gruetzmacher, Kathleen M.; Bustos, Roland M.; Ferran, Scott G.; Gallegos, Lucas E. [Los Alamos National Laboratory, Los Alamos, New Mexico 87545 (United States); Lucero, Randy P. [Pajarito Scientific Corporation, Santa Fe, New Mexico 87507 (United States)

    2012-07-01

    Los Alamos National Laboratory (LANL) uses the Nevada National Security Site (NNSS) as an off-site disposal facility for low-level waste (LLW), including sludge waste. NNSS has issued a position paper that indicates that systems that are not certified by the Carlsbad Field Office (CBFO) for Waste Isolation Pilot Plant (WIPP) disposal of Transuranic (TRU) waste must demonstrate equivalent practices to the CBFO certified systems in order to assign activity concentration values to assayed items without adding in the Total Measurement Uncertainty (TMU) when certifying waste for NNSS disposal. Efforts have been made to meet NNSS requirements to accept sludge waste for disposal at their facility. The LANL LLW Characterization Team uses portable high purity germanium (HPGe) detector systems for the nondestructive assay (NDA) of both debris and sludge LLW. A number of performance studies have been conducted historically by LANL to support the efficacy and quality of assay results generated by the LANL HPGe systems, and, while these detector systems are supported by these performance studies and used with LANL approved procedures and processes, they are not certified by CBFO for TRU waste disposal. Beginning in 2009, the LANL LLW Characterization Team undertook additional NDA measurements of both debris and sludge simulated waste containers to supplement existing studies and procedures to demonstrate full compliance with the NNSS position paper. Where possible, Performance Demonstration Project (PDP) drums were used for the waste matrix and PDP sources were used for the radioactive sources. Sludge drums are an example of a matrix with a uniform distribution of contaminants. When attempting to perform a gamma assay of a sludge drum, it is very important to adequately simulate this uniform distribution of radionuclides in order to accurately model the assay results. This was accomplished by using a spiral radial source tube placement in a sludge drum rather than the standard

  17. Computer-controlled detection system for high-precision isotope ratio measurements

    International Nuclear Information System (INIS)

    McCord, B.R.; Taylor, J.W.

    1986-01-01

    In this paper the authors describe a detection system for high-precision isotope ratio measurements. In this new system, the requirement for a ratioing digital voltmeter has been eliminated, and a standard digital voltmeter interfaced to a computer is employed. Instead of measuring the ratio of the two steadily increasing output voltages simultaneously, the digital voltmeter alternately samples the outputs at a precise rate over a certain period of time. The data are sent to the computer which calculates the rate of charge of each amplifier and divides the two rates to obtain the isotopic ratio. These results simulate a coincident measurement of the output of both integrators. The charge rate is calculated by using a linear regression method, and the standard error of the slope gives a measure of the stability of the system at the time the measurement was taken

  18. Raman scattering method and apparatus for measuring isotope ratios and isotopic abundances

    International Nuclear Information System (INIS)

    Harney, R.C.; Bloom, S.D.

    1978-01-01

    Raman scattering is used to measure isotope ratios and/or isotopic abundances. A beam of quasi-monochromatic photons is directed onto the sample to be analyzed, and the resulting Raman-scattered photons are detected and counted for each isotopic species of interest. These photon counts are treated mathematically to yield the desired isotope ratios or isotopic abundances

  19. Fat to muscle ratio measurements with dual energy x-ray absorbtiometry

    Energy Technology Data Exchange (ETDEWEB)

    Chen, A. [Shenzhen College of International Education, 1st HuangGang Park St., Shenzhen, GuangDong (China); Luo, J. [Department of Biomedical Engineering, University at Buffalo, 332 Bonner Hall, Buffalo, NY 14260-1920 (United States); Wang, A. [Department of Computer Science, Carnegie Mellon University, Pittsburgh, PA 15213 (United States); Broadbent, C. [School of Engineering, Columbia University, 1130 Amsterdam Av., New York, NY 10027 (United States); Zhong, J. [Department of English, Dartmouth College, 6032 Sanborn House, Hanover, NH 03755 (United States); Dilmanian, F.A. [Departments of Radiation Oncology, Neurology, and Radiology, Stony Brook University, Stony Brook, NY 11794 (United States); Zafonte, F.; Zhong, Z. [National Synchrotron Light Source II, Brookhaven National Laboratory, Bldg. 743, Upton, NY 11973 (United States)

    2015-07-11

    Accurate measurement of the fat-to-muscle ratio in animal model is important for obesity research. An efficient way to measure the fat to muscle ratio in animal model using dual-energy absorptiometry is presented in this paper. A radioactive source exciting x-ray fluorescence from a target material is used to provide the two x-ray energies needed. The x-rays, after transmitting through the sample, are measured with an energy-sensitive Ge detector. Phantoms and specimens were measured. The results showed that the method was sensitive to the fat to muscle ratios with good linearity. A standard deviation of a few percent in the fat to muscle ratio could be observed with the x-ray dose of 0.001 mGy.

  20. Principles of fuel ion ratio measurements in fusion plasmas by collective Thomson scattering

    DEFF Research Database (Denmark)

    Stejner Pedersen, Morten; Nielsen, Stefan Kragh; Bindslev, Henrik

    2011-01-01

    ratio. Measurements of the fuel ion ratio will be important for plasma control and machine protection in future experiments with burning fusion plasmas. Here we examine the theoretical basis for fuel ion ratio measurements by CTS. We show that the sensitivity to plasma composition is enhanced......For certain scattering geometries collective Thomson scattering (CTS) measurements are sensitive to the composition of magnetically confined fusion plasmas. CTS therefore holds the potential to become a new diagnostic for measurements of the fuel ion ratio—i.e. the tritium to deuterium density...... by the signatures of ion cyclotron motion and ion Bernstein waves which appear for scattering geometries with resolved wave vectors near perpendicular to the magnetic field. We investigate the origin and properties of these features in CTS spectra and give estimates of their relative importance for fuel ion ratio...

  1. Evaluation of electrical impedance ratio measurements in accuracy of electronic apex locators.

    Science.gov (United States)

    Kim, Pil-Jong; Kim, Hong-Gee; Cho, Byeong-Hoon

    2015-05-01

    The aim of this paper was evaluating the ratios of electrical impedance measurements reported in previous studies through a correlation analysis in order to explicit it as the contributing factor to the accuracy of electronic apex locator (EAL). The literature regarding electrical property measurements of EALs was screened using Medline and Embase. All data acquired were plotted to identify correlations between impedance and log-scaled frequency. The accuracy of the impedance ratio method used to detect the apical constriction (APC) in most EALs was evaluated using linear ramp function fitting. Changes of impedance ratios for various frequencies were evaluated for a variety of file positions. Among the ten papers selected in the search process, the first-order equations between log-scaled frequency and impedance were in the negative direction. When the model for the ratios was assumed to be a linear ramp function, the ratio values decreased if the file went deeper and the average ratio values of the left and right horizontal zones were significantly different in 8 out of 9 studies. The APC was located within the interval of linear relation between the left and right horizontal zones of the linear ramp model. Using the ratio method, the APC was located within a linear interval. Therefore, using the impedance ratio between electrical impedance measurements at different frequencies was a robust method for detection of the APC.

  2. Evaluation of electrical impedance ratio measurements in accuracy of electronic apex locators

    Directory of Open Access Journals (Sweden)

    Pil-Jong Kim

    2015-05-01

    Full Text Available Objectives The aim of this paper was evaluating the ratios of electrical impedance measurements reported in previous studies through a correlation analysis in order to explicit it as the contributing factor to the accuracy of electronic apex locator (EAL. Materials and Methods The literature regarding electrical property measurements of EALs was screened using Medline and Embase. All data acquired were plotted to identify correlations between impedance and log-scaled frequency. The accuracy of the impedance ratio method used to detect the apical constriction (APC in most EALs was evaluated using linear ramp function fitting. Changes of impedance ratios for various frequencies were evaluated for a variety of file positions. Results Among the ten papers selected in the search process, the first-order equations between log-scaled frequency and impedance were in the negative direction. When the model for the ratios was assumed to be a linear ramp function, the ratio values decreased if the file went deeper and the average ratio values of the left and right horizontal zones were significantly different in 8 out of 9 studies. The APC was located within the interval of linear relation between the left and right horizontal zones of the linear ramp model. Conclusions Using the ratio method, the APC was located within a linear interval. Therefore, using the impedance ratio between electrical impedance measurements at different frequencies was a robust method for detection of the APC.

  3. Long distance elementary measurement of the radiation dose ratio produced by neutron activation

    International Nuclear Information System (INIS)

    Zhou Changgeng; Lou Benchao; Wu Chunlei; Hu Yonghong; Li Yan

    2009-04-01

    The working principle and the structure and performances of a long distance controllable individual radiation dose ratio instrument are described. The radiation dose ratio produced by neutron activation is elementarily measured by using this instrument in the neutron generator hall with high neutron yield. When neutron yield arrives to 2 x 10 11 s -1 , the radiation dose ratio produced by neutron activation is 99.9 μSv/h in 1 h after the generator being stopped. The radiation dose ratio is reduced to 24.4 μSv/h in 39 h after the generator being stopped. When neutron yield is 3.2 x 10 10 s -1 , the radiation dose ratio produced by neutron activation is 21.9 μSv/h in 36 min, after the generator being stopped. The measurement results may provide reference for physical experimenters and neutron generator operators. (authors)

  4. Measurement of the atmospheric muon charge ratio with the OPERA detector

    CERN Document Server

    Agafonova, N.; Aoki, S.; Ariga, A.; Ariga, T.; Autiero, D.; Badertscher, A.; Bagulya, A.; Bertolin, A.; Besnier, M.; Bick, D.; Boyarkin, V.; Bozza, C.; Brugiere, T.; Brugnera, R.; Brunetti, G.; Buontempo, S.; Cazes, A.; Chaussard, L.; Chernyavsky, M.; Chiarella, V.; Chon-Sen, N.; Chukanov, A.; Cozzi, M.; D'Amato, G.; Dal Corso, F.; D'Ambrosio, N.; De Lellis, G.; Declais, Y.; De Serio, M.; Di Capua, F.; Di Ferdinando, D.; Di Giovanni, A.; Di Marco, N.; Dmitrievski, S.; Dracos, M.; Duchesneau, D.; Dusini, S.; Ebert, J.; Egorov, O.; Enikeev, R.; Ereditato, A.; Esposito, L.S.; Favier, J.; Felici, G.; Ferber, T.; Fini, R.; Frekers, D.; Fukuda, T.; Fukushima, C.; Galkin, V.I.; Garfagnini, A.; Giacomelli, G.; Giorgini, M.; Goellnitz, C.; Goldberg, J.; Golubkov, D.; Goncharova, L.; Gornushkin, Y.; Grella, G.; Grianti, F.; Guler, M.; Gustavino, C.; Hagner, C.; Hamada, K.; Hara, T.; Hierholzer, M.; Hoshino, K.; Ieva, M.; Jakovcic, K.; Jollet, C.; Juget, F.; Kazuyama, M.; Kim, S.H.; Kimura, M.; Klicek, B.; Knuesel, J.; Kodama, K.; Komatsu, M.; Kose, U.; Kreslo, I.; Kubota, H.; Lazzaro, C.; Lenkeit, J.; Ljubicic, A.; Longhin, A.; Lutter, G.; Malgin, A.; Mandrioli, G.; Marotta, A.; Marteau, J.; Matsuo, T.; Matveev, V.; Mauri, N.; Medinaceli, E.; Meisel, F.; Meregaglia, A.; Migliozzi, P.; Mikado, S.; Miyamoto, S.; Monacelli, P.; Morishima, K.; Moser, U.; Muciaccia, M.T.; Naganawa, N.; Naka, T.; Nakamura, M.; Nakano, T.; Naumov, D.; Nikitina, V.; Niwa, K.; Nonoyama, Y.; Ogawa, S.; Olchevski, A.; Oldorf, C.; Orlova, G.; Osedlo, V.; Paniccia, M.; Paoloni, A.; Park, B.D.; Park, I.G.; Pastore, A.; Patrizii, L.; Pennacchio, E.; Pessard, H.; Pilipenko, V.; Pistillo, C.; Policastro, G.; Polukhina, N.; Pozzato, M.; Pretzl, K.; Publichenko, P.; Pupilli, F.; Rescigno, R.; Roganova, T.; Rokujo, H.; Romano, G.; Rosa, G.; Rostovtseva, I.; Rubbia, A.; Russo, A.; Ryasny, V.; Ryazhskaya, O.; Sato, O.; Sato, Y.; Schembri, A.; Schmidt Parzefall, W.; Schroeder, H.; Scotto Lavina, L.; Sheshukov, A.; Shibuya, H.; Simone, S.; Sioli, M.; Sirignano, C.; Sirri, G.; Song, J.S.; Spinetti, M.; Stanco, L.; Starkov, N.; Stipcevic, M.; Strauss, T.; Strolin, P.; Takahashi, S.; Tenti, M.; Terranova, F.; Tezuka, I.; Tioukov, V.; Tolun, P.; Tran, T.; Tufanli, S.; Vilain, P.; Vladimirov, M.; Votano, L.; Vuilleumier, J.L.; Wilquet, G.; Wonsak, B.; Yakushev, V.; Yoon, C.S.; Yoshioka, T.; Yoshida, J.; Zaitsev, Y.; Zemskova, S.; Zghiche, A.; Zimmermann, R.

    2010-01-01

    The OPERA detector at the Gran Sasso underground laboratory (LNGS) was used to measure the atmospheric muon charge ratio in the TeV energy region. We analyzed 403069 atmospheric muons corresponding to 113.4 days of livetime during the 2008 CNGS run. We computed separately the muon charge ratio for single and for multiple muon events in order to select different energy regions of the primary cosmic ray spectrum and to test the charge ratio dependence on the primary composition. The measured charge ratio values were corrected taking into account the charge-misidentification errors. Data have also been grouped in five bins of the "vertical surface energy". A fit to a simplified model of muon production in the atmosphere allowed the determination of the pion and kaon charge ratios weighted by the cosmic ray energy spectrum.

  5. Effective dose equivalent

    International Nuclear Information System (INIS)

    Huyskens, C.J.; Passchier, W.F.

    1988-01-01

    The effective dose equivalent is a quantity which is used in the daily practice of radiation protection as well as in the radiation hygienic rules as measure for the health risks. In this contribution it is worked out upon which assumptions this quantity is based and in which cases the effective dose equivalent can be used more or less well. (H.W.)

  6. Measurement of the initial conversion ratio in AQUILON and EDF 2 reactors

    International Nuclear Information System (INIS)

    Bergeron, J.; Le Baud, P.; Sautiez, B.

    1968-01-01

    In natural uranium fuelled reactors, it is important to know the initial conversion ratio, i.e. the ratio of uranium 238 absorption to uranium 235 destruction. The separation of absorption products from fission products is a difficult feature in the measurement of the conversion ratio. A physical method was chosen, the γγ coincidence technique which uses the properties of the decay scheme of neptunium 239 and allows the neptunium activity to be separated from the fission product activity, with some corrections. Detectors of natural uranium are used. The accuracy obtained in the measurements is of the order of 2%. (authors) [fr

  7. Effect of heterophoria measurement technique on the clinical accommodative convergence to accommodation ratio.

    Science.gov (United States)

    Escalante, Jaime Bernal; Rosenfield, Mark

    2006-05-01

    Measurement of the stimulus accommodative convergence to accommodation (AC/A) ratio is a standard procedure in clinical optometric practice. Typically, heterophoria is assessed at several accommodative stimulus levels, and the gradient of the vergence to accommodation function computed. A number of procedures are available for the subjective measurement of heterophoria, but it is unclear whether the use of different vergence measurement techniques will alter the obtained AC/A value. Accordingly, the current study compared AC/A ratios measured using 3 clinical subjective heterophoria tests, namely the von Graefe (VG), Maddox Rod (MR), and Modified Thorington (MT) procedures. The AC/A ratio was measured in 60 visually normal subjects between 20 and 25 years of age using each of the 3 procedures listed above. The accommodative stimulus was varied by the introduction of +/-1.00 diopter (D) spherical lenses over the distance refractive correction while subjects viewed a target at a viewing distance of 40 cm. To examine the repeatability of each procedure, the AC/A ratio was measured on 2 separate occasions for each measurement technique, with the 2 sessions being separated by at least 24 hours. Mean values of stimulus AC/A ratio measured using the VG, MR, and MT procedures were 3.47, 2.99, and 2.46Delta/D, respectively. These differences were significant (p=0.0001). In addition, the coefficient of repeatability for the 3 techniques was 2.22, 1.99, and 1.20 Delta/D, respectively. Ratios obtained using the Modified Thorington technique with +/-1.00 D lenses showed the best repeatability, whereas the poorest repeatability was found with the von Graefe technique when only +1.00 D lenses were used to vary the accommodative stimulus. Accordingly, we recommend that that Modified Thorington procedure with +/-1.00 D lenses be used to quantify heterophoria during clinical measurement of the stimulus AC/A ratio.

  8. Measurement of the super-allowed branching ratio of $^{10}$C

    CERN Multimedia

    We propose to measure the super-allowed branching ratio of $^{10}$C, the lightest of all nuclei decaying by a $0^{+} \\rightarrow 0^{+}$ transition. The light nuclei have a much stronger impact on limits of physics beyond the standard model than heavier nuclei. We propose a measurement which should reach a precision similar to the two latest measurements, however, with a different method employing a precisely efficiency-calibrated germanium detector. As no method exists to greatly improve on previous results, the branching ratio has to be measured with independent methods.

  9. Measurement of Poisson's ratio of nonmetallic materials by laser holographic interferometry

    Science.gov (United States)

    Zhu, Jian T.

    1991-12-01

    By means of the off-axis collimated plane wave coherent light arrangement and a loading device by pure bending, Poisson's ratio values of CFRP (carbon fiber-reinforced plactics plates, lay-up 0 degree(s), 90 degree(s)), GFRP (glass fiber-reinforced plactics plates, radial direction) and PMMA (polymethyl methacrylate, x, y direction) have been measured. In virtue of this study, the ministry standard for the Ministry of Aeronautical Industry (Testing method for the measurement of Poisson's ratio of non-metallic by laser holographic interferometry) has been published. The measurement process is fast and simple. The measuring results are reliable and accurate.

  10. Measurements of K shell absorption jump factors and jump ratios using EDXRF technique

    Science.gov (United States)

    Kacal, Mustafa Recep; Han, İbrahim; Akman, Ferdi

    2015-04-01

    In the present work, the K-shell absorption jump factors and jump ratios for 30 elements between Ti ( Z = 22) and Er ( Z = 68) were measured by energy dispersive X-ray fluorescence (EDXRF) technique. The jump factors and jump ratios for these elements were determined by measuring the K shell fluorescence parameters such as the Kα X-ray production cross-sections, K shell fluorescence yields, Kβ-to- Kα X-rays intensity ratios, total atomic absorption cross sections and mass attenuation coefficients. The measurements were performed using an Am-241 radioactive point source and a Si (Li) detector in direct excitation and transmission experimental geometry. The results for jump factors and jump ratios were compared with theoretically calculated and the ones available in the literature.

  11. A meta-analytic review of measurement equivalence study findings of the SF-36® and SF-12® Health Surveys across electronic modes compared to paper administration.

    Science.gov (United States)

    White, Michelle K; Maher, Stephen M; Rizio, Avery A; Bjorner, Jakob B

    2018-04-16

    Patient-reported outcome (PRO) measures originally developed for paper administration are increasingly being administered electronically in clinical trials and other health research studies. Three published meta-analyses of measurement equivalence among paper and electronic modes aggregated findings across hundreds of PROs, but there has not been a similar meta-analysis that addresses a single PRO, partly because there are not enough published measurement equivalence studies using the same PRO. Because the SF-36 (R) Health Survey (SF-36) is a widely used PRO, the aim of this study was to conduct a meta-analysis of measurement equivalence studies of this survey. A literature search of several medical databases used search terms for variations of "SF-36" or "SF-12" and "equivalence" in the title or abstract of English language publications. The eight scale scores and two summary measures of the SF-36 and SF-12 were transformed to norm-based scores (NBS) using developer guidelines. A threshold of within ± 2 NBS points was set as the margin of equivalence. Comprehensive meta-analysis software was used. Twenty-five studies were included in the meta-analysis. Results indicated that mean differences across domains and summary scores ranged from 0.01 to 0.39 while estimates of agreement ranged from 0.76 to 0.91, all well within the equivalence threshold. Moderator analyses showed that time between administration, survey language, and type of electronic device did not influence equivalence. The results of the meta-analysis support equivalence of paper-based and electronic versions of the SF-36 and SF-12 across a variety of disease populations, countries, and electronic modes.

  12. Measurement of the inclusive charmless and double-charm B branching ratios

    CERN Document Server

    Abreu, P; Adye, T; Adzic, P; Alekseev, G D; Alemany, R; Allport, P P; Almehed, S; Amaldi, Ugo; Amato, S; Andersson, P; Andreazza, A; Antilogus, P; Apel, W D; Arnoud, Y; Åsman, B; Augustin, J E; Augustinus, A; Baillon, Paul; Bambade, P; Barão, F; Barbier, R; Bardin, Dimitri Yuri; Barker, G; Baroncelli, A; Bärring, O; Bates, M J; Battaglia, Marco; Baubillier, M; Becks, K H; Begalli, M; Beillière, P; Belokopytov, Yu A; Belous, K S; Benvenuti, Alberto C; Bérat, C; Berggren, M; Bertini, D; Bertrand, D; Besançon, M; Bianchi, F; Bigi, M; Bilenky, S M; Billoir, P; Bizouard, M A; Bloch, D; Bonesini, M; Bonivento, W; Boonekamp, M; Booth, P S L; Borgland, A W; Borisov, G; Bosio, C; Botner, O; Boudinov, E; Bouquet, B; Bourdarios, C; Bowcock, T J V; Bozovic, I; Bozzo, M; Branchini, P; Brand, K D; Brenke, T; Brenner, R A; Brown, R; Brückman, P; Brunet, J M; Bugge, L; Buran, T; Burgsmüller, T; Buschmann, P; Cabrera, S; Caccia, M; Calvi, M; Camacho-Rozas, A J; Camporesi, T; Canale, V; Canepa, M; Carena, F; Carroll, L; Caso, Carlo; Castillo-Gimenez, M V; Cattai, A; Cavallo, F R; Cerruti, C; Chabaud, V; Chapkin, M M; Charpentier, P; Chaussard, L; Checchia, P; Chelkov, G A; Chen, M; Chierici, R; Chliapnikov, P V; Chochula, P; Chorowicz, V; Chudoba, J; Collins, P; Colomer, M; Contri, R; Cortina, E; Cosme, G; Cossutti, F; Cowell, J H; Crawley, H B; Crennell, D J; Crosetti, G; Cuevas-Maestro, J; Czellar, S; D'Almagne, B; Damgaard, G; Dauncey, P D; Davenport, Martyn; Da Silva, W; Deghorain, A; Della Ricca, G; Delpierre, P A; Demaria, N; De Angelis, A; de Boer, Wim; De Brabandere, S; De Clercq, C; La Vaissière, C de; De Lotto, B; De Min, A; De Paula, L S; Dijkstra, H; Di Ciaccio, Lucia; Di Diodato, A; Djannati, A; Dolbeau, J; Doroba, K; Dracos, M; Drees, J; Drees, K A; Dris, M; Duperrin, A; Durand, J D; Edsall, D M; Ehret, R; Eigen, G; Ekelöf, T J C; Ekspong, Gösta; Ellert, M; Elsing, M; Engel, J P; Erzen, B; Espirito-Santo, M C; Falk, E; Fanourakis, G K; Fassouliotis, D; Fayot, J; Feindt, Michael; Fenyuk, A; Ferrari, P; Ferrer, A; Fichet, S; Firestone, A; Fischer, P A; Flagmeyer, U; Föth, H; Fokitis, E; Fontanelli, F; Formenti, F; Franek, B J; Frodesen, A G; Frühwirth, R; Fulda-Quenzer, F; Fuster, J A; Galloni, A; Gamba, D; Gandelman, M; García, C; García, J; Gaspar, C; Gaspar, M; Gasparini, U; Gavillet, P; Gazis, E N; Gelé, D; Gerber, J P; Gerdyukov, L N; Ghodbane, N; Glege, F; Gokieli, R; Golob, B; González-Caballero, I; Gopal, Gian P; Gorn, L; Górski, M; Gracco, Valerio; Grahl, J; Graziani, E; Green, C; Grefrath, A; Gris, P; Grosdidier, G; Grzelak, K; Günther, M; Guy, J; Hahn, F; Hahn, S; Haider, S; Hajduk, Z; Hallgren, A; Hamacher, K; Harris, F J; Hedberg, V; Heising, S; Henriques, R P; Hernández, J J; Herquet, P; Herr, H; Hessing, T L; Heuser, J M; Higón, E; Holmgren, S O; Holt, P J; Holthuizen, D J; Hoorelbeke, S; Houlden, M A; Hrubec, Josef; Huet, K; Hultqvist, K; Jackson, J N; Jacobsson, R; Jalocha, P; Janik, R; Jarlskog, C; Jarlskog, G; Jarry, P; Jean-Marie, B; Johansson, E K; Jönsson, L B; Jönsson, P E; Joram, C; Juillot, P; Kapusta, F; Karafasoulis, K; Katsanevas, S; Katsoufis, E C; Keränen, R; Khokhlov, Yu A; Khomenko, B A; Khovanskii, N N; King, B J; Kjaer, N J; Klapp, O; Klein, H; Kluit, P M; Knoblauch, D; Kokkinias, P; Koratzinos, M; Korcyl, K; Kostyukhin, V; Kourkoumelis, C; Kuznetsov, O; Krammer, Manfred; Kreuter, C; Kronkvist, I J; Krumshtein, Z; Kubinec, P; Kucewicz, W; Kurvinen, K L; Lacasta, C; Lamsa, J; Lanceri, L; Lane, D W; Langefeld, P; Laugier, J P; Lauhakangas, R; Leder, Gerhard; Ledroit, F; Lefébure, V; Legan, C K; Leisos, A; Leitner, R; Lemonne, J; Lenzen, Georg; Lepeltier, V; Lesiak, T; Lethuillier, M; Libby, J; Liko, D; Lipniacka, A; Lippi, I; Lörstad, B; Loken, J G; Lopes, J H; López, J M; Loukas, D; Lutz, P; Lyons, L; MacNaughton, J N; Mahon, J R; Maio, A; Malek, A; Malmgren, T G M; Malychev, V; Mandl, F; Marco, J; Marco, R P; Maréchal, B; Margoni, M; Marin, J C; Mariotti, C; Markou, A; Martínez-Rivero, C; Martínez-Vidal, F; Martí i García, S; Matorras, F; Matteuzzi, C; Matthiae, Giorgio; Mazzucato, F; Mazzucato, M; McCubbin, M L; McKay, R; McNulty, R; McPherson, G; Medbo, J; Meroni, C; Meyer, W T; Michelotto, M; Migliore, E; Mirabito, L; Mitaroff, Winfried A; Mjörnmark, U; Moa, T; Møller, R; Mönig, K; Monge, M R; Moreau, X; Morettini, P; Münich, K; Mulders, M; Mundim, L M; Murray, W J; Muryn, B; Myatt, Gerald; Myklebust, T; Naraghi, F; Navarria, Francesco Luigi; Navas, S; Nawrocki, K; Negri, P; Némécek, S; Neufeld, N; Neumann, W; Neumeister, N; Nicolaidou, R; Nielsen, B S; Nieuwenhuizen, M; Nikolaenko, V; Nikolenko, M; Niss, P; Nomerotski, A; Normand, Ainsley; Nygren, A; Oberschulte-Beckmann, W; Obraztsov, V F; Olshevskii, A G; Onofre, A; Orava, Risto; Orazi, G; Österberg, K; Ouraou, A; Paganini, P; Paganoni, M; Paiano, S; Pain, R; Paiva, R; Palka, H; Papadopoulou, T D; Papageorgiou, K; Pape, L; Parkes, C; Parodi, F; Parzefall, U; Passeri, A; Pegoraro, M; Peralta, L; Pernegger, H; Pernicka, Manfred; Perrotta, A; Petridou, C; Petrolini, A; Phillips, H T; Piana, G; Pierre, F; Pimenta, M; Piotto, E; Podobnik, T; Podobrin, O; Pol, M E; Polok, G; Poropat, P; Pozdnyakov, V; Privitera, P; Pukhaeva, N; Pullia, Antonio; Radojicic, D; Ragazzi, S; Rahmani, H; Rames, J; Ratoff, P N; Read, A L; Rebecchi, P; Redaelli, N G; Regler, Meinhard; Reid, D; Reinhardt, R; Renton, P B; Resvanis, L K; Richard, F; Rídky, J; Rinaudo, G; Røhne, O M; Romero, A; Ronchese, P; Rosenberg, E I; Rosinsky, P; Roudeau, Patrick; Rovelli, T; Ruhlmann-Kleider, V; Ruiz, A; Saarikko, H; Sacquin, Yu; Sadovskii, A; Sajot, G; Salt, J; Sampsonidis, D; Sannino, M; Schneider, H; Schwickerath, U; Schyns, M A E; Scuri, F; Seager, P; Sedykh, Yu; Segar, A M; Sekulin, R L; Shellard, R C; Sheridan, A; Silvestre, R; Simonetto, F; Sissakian, A N; Skaali, T B; Smadja, G; Smirnov, N; Smirnova, O G; Smith, G R; Solovyanov, O; Sopczak, André; Sosnowski, R; Souza-Santos, D; Spassoff, Tz; Spiriti, E; Sponholz, P; Squarcia, S; Stampfer, D; Stanescu, C; Stanic, S; Stapnes, Steinar; Stavitski, I; Stevenson, K; Stocchi, A; Strauss, J; Strub, R; Stugu, B; Szczekowski, M; Szeptycka, M; Tabarelli de Fatis, T; Chikilev, O G; Tegenfeldt, F; Terranova, F; Thomas, J; Tilquin, A; Timmermans, J; Tkatchev, L G; Todorov, T; Todorova, S; Toet, D Z; Tomaradze, A G; Tomé, B; Tonazzo, A; Tortora, L; Tranströmer, G; Treille, D; Tristram, G; Trombini, A; Troncon, C; Tsirou, A L; Turluer, M L; Tyapkin, I A; Tyndel, M; Tzamarias, S; Überschär, B; Ullaland, O; Uvarov, V; Valenti, G; Vallazza, E; van Apeldoorn, G W; van Dam, P; Van Eldik, J; Van Lysebetten, A; Van Vulpen, I B; Vassilopoulos, N; Vegni, G; Ventura, L; Venus, W A; Verbeure, F; Verlato, M; Vertogradov, L S; Verzi, V; Vilanova, D; Vincent, P; Vitale, L; Vlasov, E; Vodopyanov, A S; Vrba, V; Wahlen, H; Walck, C; Waldner, F; Weiser, C; Wetherell, Alan M; Wicke, D; Wickens, J H; Wilkinson, G R; Williams, W S C; Winter, M; Witek, M; Wlodek, T; Wolf, G; Yi, J; Yushchenko, O P; Zaitsev, A; Zalewska-Bak, A; Zalewski, Piotr; Zavrtanik, D; Zevgolatakos, E; Zimin, N I; Zucchelli, G C; Zumerle, G

    1998-01-01

    The DELPHI experiment at LEP has measured the inclusive charmless $B$ hadron decay branching ratio, the $B$ branching ratio into two charmed particles, and the total number of charmed particles per $B$ decay, using the hadronic Z data taken between 1992 and 1995. The results are extracted from a fit to the $b$-tagging probability distribution based on the precise impact parameter measurements made using the microvertex detector. The inclusive charmless $B$ branching ratio, including $B$ decays into hidden charm ($c\\bar{c}$), is measured to be $0.033 \\pm 0.021$. The $B$ branching ratio into two open charmed particles is $0.136 \\pm 0.042$. The mean number of charmed particles per $B$ decay (including hidden charm) is $1.147 \\pm 0.041$. After subtracting the $B$ decay branching ratio into hidden charm, the charmless $B$ branching ratio is found to be $0.007 \\pm 0.021$, compatible with the Standard Model expectation. Models that predict an additional contribution to the charmless $B$ branching ratio of 0.037 or h...

  13. Measurement of characteristic prompt gamma rays emitted from oxygen and carbon in tissue-equivalent samples during proton beam irradiation.

    Science.gov (United States)

    Polf, Jerimy C; Panthi, Rajesh; Mackin, Dennis S; McCleskey, Matt; Saastamoinen, Antti; Roeder, Brian T; Beddar, Sam

    2013-09-07

    The purpose of this work was to characterize how prompt gamma (PG) emission from tissue changes as a function of carbon and oxygen concentration, and to assess the feasibility of determining elemental concentration in tissues irradiated with proton beams. For this study, four tissue-equivalent water-sucrose samples with differing densities and concentrations of carbon, hydrogen, and oxygen were irradiated with a 48 MeV proton pencil beam. The PG spectrum emitted from each sample was measured using a high-purity germanium detector, and the absolute detection efficiency of the detector, average beam current, and delivered dose distribution were also measured. Changes to the total PG emission from (12)C (4.44 MeV) and (16)O (6.13 MeV) per incident proton and per Gray of absorbed dose were characterized as a function of carbon and oxygen concentration in the sample. The intensity of the 4.44 MeV PG emission per incident proton was found to be nearly constant for all samples regardless of their carbon concentration. However, we found that the 6.13 MeV PG emission increased linearly with the total amount (in grams) of oxygen irradiated in the sample. From the measured PG data, we determined that 1.64 × 10(7) oxygen PGs were emitted per gram of oxygen irradiated per Gray of absorbed dose delivered with a 48 MeV proton beam. These results indicate that the 6.13 MeV PG emission from (16)O is proportional to the concentration of oxygen in tissue irradiated with proton beams, showing that it is possible to determine the concentration of oxygen within tissues irradiated with proton beams by measuring (16)O PG emission.

  14. MOSFET dosimeter depth-dose measurements in heterogeneous tissue-equivalent phantoms at diagnostic x-ray energies

    International Nuclear Information System (INIS)

    Jones, A.K.; Pazik, F.D.; Hintenlang, D.E.; Bolch, W.E.

    2005-01-01

    The objective of the present study was to explore the use of the TN-1002RD metal-oxide-semiconductor field effect transistor (MOSFET) dosimeter for measuring tissue depth dose at diagnostic photon energies in both homogeneous and heterogeneous tissue-equivalent materials. Three cylindrical phantoms were constructed and utilized as a prelude to more complex measurements within tomographic physical phantoms of pediatric patients. Each cylindrical phantom was constructed as a stack of seven 5-cm-diameter and 1-cm-thick discs of materials radiographically representative of either soft tissue (S), bone (B), or lung tissue (L) at diagnostic photon energies. In addition to a homogeneous phantom of soft tissue (SSSSSSS), two heterogeneous phantoms were constructed: SSBBSSS and SBLLBSS. MOSFET dosimeters were then positioned at the interface of each disc, and the phantoms were then irradiated at 66 kVp and 200 mAs. Measured values of absorbed dose at depth were then compared to predicated values of point tissue dose as determined via Monte Carlo radiation transport modeling. At depths exceeding 2 cm, experimental results matched the computed values of dose with high accuracy regardless of the dosimeter orientation (epoxy bubble facing toward or away from the x-ray beam). Discrepancies were noted, however, between measured and calculated point doses near the surface of the phantom (surface to 2 cm depth) when the dosimeters were oriented with the epoxy bubble facing the x-ray beam. These discrepancies were largely eliminated when the dosimeters were placed with the flat side facing the x-ray beam. It is therefore recommended that the MOSFET dosimeters be oriented with their flat sides facing the beam when they are used at shallow depths or on the surface of either phantoms or patients

  15. Measurement of a Cosmographic Distance Ratio with Galaxy and Cosmic Microwave Background Lensing.

    Science.gov (United States)

    Miyatake, Hironao; Madhavacheril, Mathew S; Sehgal, Neelima; Slosar, Anže; Spergel, David N; Sherwin, Blake; van Engelen, Alexander

    2017-04-21

    We measure the gravitational lensing shear signal around dark matter halos hosting constant mass galaxies using light sources at z∼1 (background galaxies) and at the surface of last scattering at z∼1100 (the cosmic microwave background). The galaxy shear measurement uses data from the CFHTLenS survey, and the microwave background shear measurement uses data from the Planck satellite. The ratio of shears from these cross-correlations provides a purely geometric distance measurement across the longest possible cosmological lever arm. This is because the matter distribution around the halos, including uncertainties in galaxy bias and systematic errors such as miscentering, cancels in the ratio for halos in thin redshift slices. We measure this distance ratio in three different redshift slices of the constant mass (CMASS) sample and combine them to obtain a 17% measurement of the distance ratio, r=0.390_{-0.062}^{+0.070}, at an effective redshift of z=0.53. This is consistent with the predicted ratio from the Planck best-fit cold dark matter model with a cosmological constant cosmology of r=0.419.

  16. New Measurement of the π → eν branching ratio

    International Nuclear Information System (INIS)

    Dixit, M.S.; Bryman, D.A.; Dubois, R.; Numao, T.; Olaniyi, B.; Olin, A.; Berghofer, D.; Poutissou, J.-M.; Macdonald, J.A.

    1982-11-01

    A new measurement of the π → eν branching ratio yields GAMMA(π→eν + π→eνγ) / GAMMA(π→μν + π→γνμ) = (1.218 +- 0.014) x 10 -4 . The measured value is in good agreement with the standard model prediction incorporating electron-muon universality

  17. Measurement of the super-allowed branching ratio of $^{22}$Mg

    CERN Multimedia

    We propose to measure the super-allowed branching ratio and the half-life of $^{22}$Mg, one of the least-well-measured $0^{+} \\rightarrow 0^{+}$ transitions of the 14 nuclei used to determine V$_{ud}$ and to test the unitarity of the CKM matrix. We propose measurements which should allow to significantly improve the precision on the super-allowed branching ratio employing a precisely efficiency calibrated germanium detector and on the half-life. As no method exists to greatly improve (e.g. an order of magnitude) on previous results, the branching ratio and the half-life have to be measured several times with independent methods and in independent experiments.

  18. Measurement of the charge ratio of atmospheric muons with the CMS detector

    Energy Technology Data Exchange (ETDEWEB)

    Khachatryan, Vardan [Yerevan Physics Inst. (Armenia); et al.

    2010-08-01

    We present a measurement of the ratio of positive to negative muon fluxes from cosmic ray interactions in the atmosphere, using data collected by the CMS detector both at ground level and in the underground experimental cavern at the CERN LHC. Muons were detected in the momentum range from 5 GeV/c to 1 TeV/c. The surface flux ratio is measured to be 1.2766 \\pm 0.0032(stat.) \\pm 0.0032 (syst.), independent of the muon momentum, below 100 GeV/c. This is the most precise measurement to date. At higher momenta the data are consistent with an increase of the charge ratio, in agreement with cosmic ray shower models and compatible with previous measurements by deep-underground experiments.

  19. Estimation of (n,f) Cross-Sections by Measuring Reaction Probability Ratios

    Energy Technology Data Exchange (ETDEWEB)

    Plettner, C; Ai, H; Beausang, C W; Bernstein, L A; Ahle, L; Amro, H; Babilon, M; Burke, J T; Caggiano, J A; Casten, R F; Church, J A; Cooper, J R; Crider, B; Gurdal, G; Heinz, A; McCutchan, E A; Moody, K; Punyon, J A; Qian, J; Ressler, J J; Schiller, A; Williams, E; Younes, W

    2005-04-21

    Neutron-induced reaction cross-sections on unstable nuclei are inherently difficult to measure due to target activity and the low intensity of neutron beams. In an alternative approach, named the 'surrogate' technique, one measures the decay probability of the same compound nucleus produced using a stable beam on a stable target to estimate the neutron-induced reaction cross-section. As an extension of the surrogate method, in this paper they introduce a new technique of measuring the fission probabilities of two different compound nuclei as a ratio, which has the advantage of removing most of the systematic uncertainties. This method was benchmarked in this report by measuring the probability of deuteron-induced fission events in coincidence with protons, and forming the ratio P({sup 236}U(d,pf))/P({sup 238}U(d,pf)), which serves as a surrogate for the known cross-section ratio of {sup 236}U(n,f)/{sup 238}U(n,f). IN addition, the P({sup 238}U(d,d{prime}f))/P({sup 236}U(d,d{prime}f)) ratio as a surrogate for the {sup 237}U(n,f)/{sup 235}U(n,f) cross-section ratio was measured for the first time in an unprecedented range of excitation energies.

  20. Measurement of β/Λ ratio in IEA-R1 reactor using noise technique

    International Nuclear Information System (INIS)

    Moreira, J.M.L.; Kassar, E.

    1986-01-01

    The ratio β/Λ for the IEA-R1 reactor is obtained experimentally through the noise analysis technique. This technique is based on the determination of the power spectral density of the reactor neutron population, with the reactor in a subcritical state driven by a 'white' neutron source. A ratio β/Λ of 43,5 s -1 is estimated from the break frequency of the measured transfer function of the IEA-R1 reactor. (Author) [pt

  1. Measurement of the atmospheric muon charge ratio with the OPERA detector

    OpenAIRE

    Mauri, Nicoletta

    2011-01-01

    The atmospheric muon charge ratio, defined as the number of positive over negative charged muons, is an interesting quantity for the study of high energy hadronic interactions in atmosphere and the nature of the primary cosmic rays. The measurement of the charge ratio in the TeV muon energy range allows to study the hadronic interactions in kinematic regions not yet explored at accelerators. The OPERA experiment is a hybrid electronic detector/emulsion apparatus, located in the undergroun...

  2. Measurement of the cosmic ray muon charge ratio with the OPERA detector

    International Nuclear Information System (INIS)

    Mauri, N.; Sioli, M.

    2012-01-01

    The OPERA detector at the Gran Sasso underground laboratory (LNGS) was used to measure the cosmic ray muon charge ratio R μ =N μ + /N μ − in the TeV energy region. R μ is shown as a function of the “vertical surface energy” E μ cosθ. A fit to a simplified model of muon production in atmosphere allowed the determination of the pion and kaon charge ratios weighted by the cosmic ray energy spectrum.

  3. Evaluation of precision in measurements of uranium isotope ratio by thermionic mass spectrometry

    International Nuclear Information System (INIS)

    Moraes, N.M.P. de; Rodrigues, C.

    1977-01-01

    The parameters which affect the precision and accuracy of uranium isotopic ratios measurements by thermionic mass spectrometry are discussed. A statistical designed program for the analysis of the internal and external variances are presented. It was done an application of this statistical methods, in order to get mass discrimination factor, and its standard mean deviation, by using some results already published for 235 U/ 238 U ratio in NBS uranium samples, and natural uranium [pt

  4. An approach for measuring the {sup 129}I/{sup 127}I ratio in fish samples

    Energy Technology Data Exchange (ETDEWEB)

    Kusuno, Haruka, E-mail: kusuno@um.u-tokyo.ac.jp [The University Museum, The University of Tokyo, 3-7-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Matsuzaki, Hiroyuki [The University Museum, The University of Tokyo, 3-7-1 Hongo, Bunkyo-ku, Tokyo 113-0033 (Japan); Nagata, Toshi; Miyairi, Yosuke; Yokoyama, Yusuke [Atmosphere and Ocean Research Institute, The University of Tokyo, 5-1-5, Kashiwanoha, Kashiwa-shi, Chiba 277-8564 (Japan); Ohkouchi, Naohiko [Japan Agency for Marine-Earth Science and Technology, 2-15, Natsushima-cho, Yokosuka-city, Kanagawa 237-0061 (Japan)

    2015-10-15

    The {sup 129}I/{sup 127}I ratio in marine fish samples was measured employing accelerator mass spectrometry. The measurement was successful because of the low experimental background of {sup 129}I. Pyrohydrolysis was applied to extract iodine from fish samples. The experimental background of pyrohydrolysis was checked carefully and evaluated as 10{sup 4}–10{sup 5} atoms {sup 129}I/combustion. The methodology employed in the present study thus required only 0.05–0.2 g of dried fish samples. The methodology was then applied to obtain the {sup 129}I/{sup 127}I ratio of marine fish samples collected from the Western Pacific Ocean as (0.63–1.2) × 10{sup −10}. These values were similar to the ratio for the surface seawater collected at the same station, 0.4 × 10{sup −10}. The {sup 129}I/{sup 127}I ratio of IAEA-414, which was a mix of fish from the Irish Sea and the North Sea, was also measured and determined as 1.82 × 10{sup −7}. Consequently, fish from the Western Pacific Ocean and the North Sea were distinguished by their {sup 129}I/{sup 127}I ratios. The {sup 129}I/{sup 127}I ratio is thus a direct indicator of the area of habitat of fish.

  5. Intercomparison of measurements of personal dose equivalent Hp(10) in photon fields in the West Asia Region

    International Nuclear Information System (INIS)

    2007-01-01

    In accordance with its statutory function, the International Atomic Energy Agency (IAEA) has been assisting its Member States in establishing and upgrading their radiation protection infrastructures, including activities in occupation radiation protection. Individual external dosimetry services for photon radiation have been under establishment or upgrading with support through the Technical Cooperation Model Projects RAW/9/006, Upgrading Radiation Protection Infrastructure (concluded in 2000), and RAW/9/008, Development of Technical Capabilities for Sustainable Radiation and Waste Safety Infrastructure (2001-2004), in all the participating countries in the West Asia Region. Two regional training courses were organized by the IAEA, in Germany in 1998, on Design, Implementation and Management of Individual Monitoring Services (IMS), and in the Syrian Arabic Republic in 2001, on Assessment of Occupational Exposure due to External Sources, under the above stated projects. However, no performance testing has yet been carried out and no regional intercomparisons have been established before in this region. Only two Member States from the region (the Syrian Arab Republic and Lebanon) participated in the interregional Intercomparison for Individual Monitoring of Radiological Measurements for Purposes of Monitoring Personal Dose Equivalent Hp(10) in 1999

  6. Validation of a dual-isotope plasma ratio method for measurement of cholesterol absorption in rats

    International Nuclear Information System (INIS)

    Zilversmit, D.B.; Hughes, L.B.

    1974-01-01

    Several methods for measuring cholesterol absorption in the rat have been compared. After administration of an oral dose of labeled cholesterol ( 14 C or 3 H) and an intravenous dose of colloidal labeled cholesterol ( 3 H or 14 C) the ratio of the two labels in plasma or whole blood 48 hr or more after dosing compared closely to the ratio of areas under the respective specific activity-time curves. The area ratio method is independent of a time lag between the appearance of oral and intravenous label in the bloodstream. Both measures of cholesterol absorption agree fairly well with a method based on measuring the unabsorbed dietary cholesterol in a pooled fecal sample. The plasma isotope ratio method gave more reproducible results than the fecal collection method when the measurement was repeated in the same animals 5 days after the first measurement. Cholesterol absorption was overestimated by the use of Tween 20-solubilized labeled cholesterol for the intravenous dose. The plasma disappearance curves of injected labeled colloidal cholesterol and cholesterol-labeled chylomicrons infused intravenously over a 3.5-h period in the same animal coincided within experimental error from the first day until 75 days after injection. The plasma isotope ratio method for cholesterol absorption gave the same results in rats practicing coprophagy as in those in which this practice was prevented. The addition of sulfaguanidine to the diet lowered cholesterol absorption as measured by the plasma isotope ratio to the same degree as that measured by the fecal collection method. (U.S.)

  7. Development and design of a bone-equivalent cortical shell phantom to determine accuracy measures on DXA and PQCT scanners

    International Nuclear Information System (INIS)

    Khoo, B.C.C.; Beck, T.J. Johns; Turk, B.; Price, R.I.

    2004-01-01

    were fairly accurately rendered by pQCT, less accurately by DXA HSA. These encouraging results provide impetus towards the design of an anthropometric hip phantom, using this CSC mixture as a cortical-bone equivalent material, for more clinically realistic accuracy measures of structural geometry derived from pQCT, DXA HSA and CT. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  8. Measurement of the fission ratio for several configurations of uranium oxide rod clusters

    International Nuclear Information System (INIS)

    Pattenden, S.K.; Patterson, C.R.

    1962-02-01

    This report describes measurements of the fission ratio for a single fuel channel of oxide rod clusters in an essentially infinite block of graphite. The measurements were made using the 'catcher-foil' technique, the activities of the catcher foils being measured by β-counting. Results are given, for 37-rod; 18-rod; 7-rod and 3-rod clusters, and are compared with theoretical predictions. (author)

  9. Absolute measurement of the isotopic ratio of a water sample with very low deuterium content

    International Nuclear Information System (INIS)

    Hagemann, R.; Nief, G.; Roth, E.

    1968-01-01

    The presence of H 3+ ions which are indistinguishable from HD + ions presents the principal difficulty encountered in the measurement of isotopic ratios of water samples with very low deuterium contents using a mass spectrometer. Thus, when the sample contains no deuterium, the mass spectrometer does not indicate zero. By producing, in situ, from the sample to be measured, water vapor with an isotopic ratio very close to zero using a small distilling column, this difficulty is overcome. This column, its operating parameters, as well as the way in which the measurements are made are described. An arrangement is employed in which the isotopic ratios can be measured with a sensitivity better than 0.01 x 10 -6 . The method is applied to the determination of the isotopic ratios of three low deuterium content water samples. The results obtained permit one to assign to the sample with the lowest deuterium content an absolute value equal to 1.71 ± 0.03 ppm. This water sample is a primary standard from which is determined the isotopic ratio of a natural water sample which serves as the laboratory standard. (author) [fr

  10. Equivalencies Regarding the Measurement and Constructs of Self-Esteem and Major Life Events in an Asian-Pacific Islander Sampler.

    Science.gov (United States)

    Miyamoto, Robin H.; Hishinuma, Earl S.; Nishimura, Stephanie T.; Nahulu, Linda B.; Andrade, Naleen N.; Johnson, Ronald C.; Makini, George K., Jr.; Yuen, Noelle Y. C.; Kim, S. Peter; Goebert, Deborah A.; Carlton, Barry S.; Bell, Cathy K.

    2001-01-01

    Examines aspects of self-esteem measures and major life events using the 10-item Rosenberg Self-Esteem Scale (RSES) with Hawaiian, part-Hawaiian, and non-Hawaiian high school students (N=816). There was a lack of consensus regarding the dimensions of RSES as previously reported. Measurement equivalency findings concerning RSES caution against…

  11. Using Rasch Measurement To Investigate the Cross-form Equivalence and Clinical Utility of Spanish and English Versions of a Diabetes Questionnaire: A Pilot Study.

    Science.gov (United States)

    Gerber, Ben; Smith, Everett V., Jr.; Girotti, Mariela; Pelaez, Lourdes; Lawless, Kimberly; Smolin, Louanne; Brodsky, Irwin; Eiser, Arnold

    2002-01-01

    Used Rasch measurement to study the psychometric properties of data obtained from a newly developed Diabetes Questionnaire designed to measure diabetes knowledge, attitudes, and self-care. Responses of 26 diabetes patients to the English version of the questionnaire and 24 patients to the Spanish version support the cross-form equivalence and…

  12. Isomeric ratio measurements for the radiative neutron capture 176Lu(n,γ at DANCE

    Directory of Open Access Journals (Sweden)

    Denis-Petit D.

    2017-01-01

    Full Text Available The isomeric ratios for the neutron capture reaction 176Lu(n,γ to the Jπ = 5/2−, 761.7 keV, T1/2 = 32.8 ns and the Jπ = 15/2+, 1356.9 keV, T1/2 = 11.1 ns levels of 177Lu, have been measured for the first time with the Detector for Advanced Neutron Capture Experiments (DANCE at the Los Alamos National Laboratory. These measured isomeric ratios are compared with TALYS calculations.

  13. Platinum stable isotope ratio measurements by double-spike multiple collector ICPMS

    DEFF Research Database (Denmark)

    Creech, John; Baker, Joel; Handler, Monica

    2013-01-01

    We present a new technique for the precise determination of platinum (Pt) stable isotope ratios by multiple-collector inductively coupled plasma mass spectrometry (MC-ICPMS) using two different Pt double-spikes ( Pt-Pt and Pt-Pt). Results are expressed relative to the IRMM-010 Pt isotope standard......) can be obtained on Pt stable isotope ratios with either double-spike. Elemental doping tests reveal that double-spike corrected Pt stable isotope ratios are insensitive to the presence of relatively high (up to 10%) levels of matrix elements, although the Pt-Pt double-spike is affected by an isobaric...... = 7.308%) results in a redefined Pt atomic weight of 195.08395 ± 0.00068. Using our technique we have measured small, reproducible and statistically significant offsets in Pt stable isotope ratios between different Pt element standards and the IRMM-010 standard, which potentially indicates...

  14. Gyrokinetic equivalence

    International Nuclear Information System (INIS)

    Parra, Felix I; Catto, Peter J

    2009-01-01

    We compare two different derivations of the gyrokinetic equation: the Hamiltonian approach in Dubin D H E et al (1983 Phys. Fluids 26 3524) and the recursive methodology in Parra F I and Catto P J (2008 Plasma Phys. Control. Fusion 50 065014). We prove that both approaches yield the same result at least to second order in a Larmor radius over macroscopic length expansion. There are subtle differences in the definitions of some of the functions that need to be taken into account to prove the equivalence.

  15. Cross-cultural measurement equivalence of the 5-level EQ-5D (EQ-5D-5L) in patients with type 2 diabetes mellitus in Singapore.

    Science.gov (United States)

    Wang, Ye; Tan, Ngiap-Chuan; Tay, Ee-Guan; Thumboo, Julian; Luo, Nan

    2015-07-16

    This study aimed to assess the measurement equivalence of the 5-level EQ-5D (EQ-5D-5L) among the English, Chinese, and Malay versions. A convenience sample of patients with type 2 diabetes mellitus were enrolled from a public primary health care institution in Singapore. The survey questionnaire comprised the EQ-5D-5L and questions assessing participants' socio-demographic and clinical characteristics. Multiple linear regression models were used to assess the difference in EQ-5D-5L index (calculated using an interim algorithm) and EQ-visual analog scale (EQ-VAS) scores across survey language (Chinese vs. English, Malay vs. English, and Malay vs. Chinese). Measurement equivalence was examined by comparing the 90% confidence interval of difference in the EQ-5D-5L index and EQ-VAS scores with a pre-determined equivalence margin. Multiple logistic regression models were used to assess the response patterns of the 5 Likert-type items of the EQ-5D-5L across survey language. Equivalence was demonstrated between the Chinese and English versions and between the Malay and English versions of the EQ-5D-5L index scores. Equivalence was also demonstrated between the Chinese and English versions and between the Malay and Chinese versions of the EQ-VAS scores. Equivalence could not be determined between the Malay and Chinese versions of the EQ-5D-5L index score and between the Malay and English versions of the EQ-VAS score. No significant difference was found in responses to EQ-5D-5L items between any languages, except that patients who chose to complete the Chinese version were more likely to report "no problems" in mobility compared to those who completed the Malay version of the questionnaire. This study provided evidence for the measurement equivalence of the different language versions of EQ-5D-5L in Singapore.

  16. The measurement of mass spectrometric peak height ratio of helium isotope in trace samples

    International Nuclear Information System (INIS)

    Sun Mingliang

    1989-01-01

    An experiment study on the measurement of mass spectrometric peak height ratio of helium isotope in the trace gaseous sample is discussed by using the gas purification line designed by the authors and model VG-5400 static-vacuum noble gas mass spectrometer imported and air helium as a standard. The results show that the amount of He and Ne in natural gas sample is 99% after purification. When the amount of He in Mass Spectrometer is more than 4 x 10 -7 cm 3 STP, it's sensitivity remains stable, about 10 -4 A/cm 3 STP He and the precision of 3 He/ 4 He ratio within the following 17 days is 1.32%. The 'ABA' pattern and experiment condition in the measurement of mass spectrometric peak height ratio of He isotope are presented

  17. Measurement of the atmospheric muon charge ratio with the OPERA detector

    International Nuclear Information System (INIS)

    Agafonova, N.; Boyarkin, V.; Enikeev, R.; Malgin, A.; Matveev, V.; Ryasny, V.; Ryazhskaya, O.; Yakushev, V.; Anokhina, A.; Galkin, V.I.; Nikitina, V.; Osedlo, V.; Publichenko, P.; Roganova, T.; Aoki, S.; Hara, T.; Rokujo, H.; Ariga, A.; Ariga, T.; Ereditato, A.; Juget, F.; Knuesel, J.; Kreslo, I.; Lutter, G.; Meisel, F.; Moser, U.; Pistillo, C.; Pretzl, K.; Vuilleumier, J.L.; Autiero, D.; Brugiere, T.; Cazes, A.; Chaussard, L.; Declais, Y.; Marteau, J.; Pennacchio, E.; Tran, T.; Badertscher, A.; Lazzaro, C.; Rubbia, A.; Strauss, T.; Bagulya, A.; Chernyavsky, M.; Goncharova, L.; Orlova, G.; Polukhina, N.; Starkov, N.; Vladimirov, M.; Bertolin, A.; Dal Corso, F.; Dusini, S.; Besnier, M.; Duchesneau, D.; Favier, J.; Pessard, H.; Zghiche, A.; Bick, D.; Ebert, J.; Ferber, T.; Goellnitz, C.; Hagner, C.; Lenkeit, J.; Oldorf, C.; Schmidt Parzefall, W.; Wonsak, B.; Zimmermann, R.; Bozza, C.; D'Amato, G.; Grella, G.; Policastro, G.; Rescigno, R.; Romano, G.; Sirignano, C.; Brugnera, R.; Garfagnini, A.; Kose, U.; Brunetti, G.; Giacomelli, G.; Giorgini, M.; Mauri, N.; Pozzato, M.; Sioli, M.; Tenti, M.; Buontempo, S.; Chukanov, A.; Di Capua, F.; Marotta, A.; Migliozzi, P.; Scotto Lavina, L.; Tioukov, V.; Chiarella, V.; Felici, G.; Grianti, F.; Paniccia, M.; Paoloni, A.; Spinetti, M.; Terranova, F.; Votano, L.; Chon-Sen, N.; Dracos, M.; Jollet, C.; Meregaglia, A.; Cozzi, M.; D'Ambrosio, N.; Di Giovanni, A.; Esposito, L.S.; Gustavino, C.; De Lellis, G.; Russo, A.; Strolin, P.; De Serio, M.; Fini, R.; Ieva, M.; Di Ferdinando, D.; Mandrioli, G.; Medinaceli, E.; Patrizii, L.; Sirri, G.; Di Marco, N.; Monacelli, P.; Park, B.D.; Park, I.G.; Pupilli, F.; Dmitrievski, S.; Gornushkin, Y.; Naumov, D.; Olchevski, A.; Sheshukov, A.; Zemskova, S.; Egorov, O.; Golubkov, D.; Rostovtseva, I.; Zaitsev, Y.; Frekers, D.; Pilipenko, V.; Fukuda, T.; Hamada, K.; Hoshino, K.; Kazuyama, M.; Komatsu, M.; Kubota, H.; Miyamoto, S.; Morishima, K.; Naganawa, N.; Naka, T.; Nakamura, M.; Nakano, T.; Niwa, K.; Nonoyama, Y.; Sato, O.; Takahashi, S.; Yoshioka, T.; Yoshida, J.; Fukushima, C.; Kimura, M.; Matsuo, T.; Mikado, S.; Ogawa, S.; Shibuya, H.; Goldberg, J.; Guler, M.; Tolun, P.; Tufanli, S.; Hierholzer, M.; Jakovcic, K.; Klicek, B.; Ljubicic, A.; Stipcevic, M.; Kim, S.H.; Song, J.S.; Yoon, C.S.; Kodama, K.; Longhin, A.; Stanco, L.; Muciaccia, M.T.; Pastore, A.; Simone, S.; Rosa, G.; Schembri, A.; Sato, Y.; Tezuka, I.; Schroeder, H.; Vilain, P.; Wilquet, G.

    2010-01-01

    The OPERA detector at the Gran Sasso underground laboratory (LNGS) was used to measure the atmospheric muon charge ratio R μ =N μ + /N μ - in the TeV energy region. We analyzed 403069 atmospheric muons corresponding to 113.4 days of lifetime during the 2008 CNGS run. We computed separately the muon charge ratio for single and for multiple muon events in order to select different energy regions of the primary cosmic ray spectrum and to test the R μ dependence on the primary composition. The measured R μ values were corrected taking into account the charge-misidentification errors. Data have also been grouped in five bins of the ''vertical surface energy'' E μ cos θ. A fit to a simplified model of muon production in the atmosphere allowed the determination of the pion and kaon charge ratios weighted by the cosmic ray energy spectrum. (orig.)

  18. Improving snow water equivalent simulations in an alpine basin using blended gage precipitation and snow pillow measurements

    Science.gov (United States)

    Sohrabi, M.; Safeeq, M.; Conklin, M. H.

    2017-12-01

    Snowpack is a critical freshwater reservoir that sustains ecosystem, natural habitat, hydropower, agriculture, and urban water supply in many areas around the world. Accurate estimation of basin scale snow water equivalent (SWE), through both measurement and modeling, has been significantly recognized to improve regional water resource management. Recent advances in remote data acquisition techniques have improved snow measurements but our ability to model snowpack evolution is largely hampered by poor knowledge of inherently variable high-elevation precipitation patterns. For a variety of reasons, majority of the precipitation gages are located in low and mid-elevation range and function as drivers for basin scale hydrologic modeling. Here, we blend observed gage precipitation from low and mid-elevation with point observations of SWE from high-elevation snow pillow into a physically based snow evolution model (SnowModel) to better represent the basin-scale precipitation field and improve snow simulations. To do this, we constructed two scenarios that differed in only precipitation. In WTH scenario, we forced the SnowModel using spatially distributed gage precipitation data. In WTH+SP scenario, the model was forced with spatially distributed precipitation data derived from gage precipitation along with observed precipitation from snow pillows. Since snow pillows do not directly measure precipitation, we uses positive change in SWE as a proxy for precipitation. The SnowModel was implemented at daily time step and 100 m resolution for the Kings River Basin, USA over 2000-2014. Our results show an improvement in snow simulation under WTH+SP as compared to WTH scenario, which can be attributed to better representation in high-elevation precipitation patterns under WTH+SP. The average Nash Sutcliffe efficiency over all snow pillow and course sites was substantially higher for WTH+SP (0.77) than for WTH scenario (0.47). The maximum difference in observed and simulated

  19. A novel method for patient exit and entrance dose prediction based on water equivalent path length measured with an amorphous silicon electronic portal imaging device

    Science.gov (United States)

    Kavuma, Awusi; Glegg, Martin; Metwaly, Mohamed; Currie, Garry; Elliott, Alex

    2010-01-01

    In vivo dosimetry is one of the quality assurance tools used in radiotherapy to monitor the dose delivered to the patient. Electronic portal imaging device (EPID) images for a set of solid water phantoms of varying thicknesses were acquired and the data fitted onto a quadratic equation, which relates the reduction in photon beam intensity to the attenuation coefficient and material thickness at a reference condition. The quadratic model is used to convert the measured grey scale value into water equivalent path length (EPL) at each pixel for any material imaged by the detector. For any other non-reference conditions, scatter, field size and MU variation effects on the image were corrected by relative measurements using an ionization chamber and an EPID. The 2D EPL is linked to the percentage exit dose table, for different thicknesses and field sizes, thereby converting the plane pixel values at each point into a 2D dose map. The off-axis ratio is corrected using envelope and boundary profiles generated from the treatment planning system (TPS). The method requires field size, monitor unit and source-to-surface distance (SSD) as clinical input parameters to predict the exit dose, which is then used to determine the entrance dose. The measured pixel dose maps were compared with calculated doses from TPS for both entrance and exit depth of phantom. The gamma index at 3% dose difference (DD) and 3 mm distance to agreement (DTA) resulted in an average of 97% passing for the square fields of 5, 10, 15 and 20 cm. The exit dose EPID dose distributions predicted by the algorithm were in better agreement with TPS-calculated doses than phantom entrance dose distributions.

  20. The value of pulmonary vessel CT measuring and calculating of relative ratio

    International Nuclear Information System (INIS)

    Ji Jiansong; Xu Xiaoxiong; Lv Suzhen; Zhao Zhongwei; Wang Zufei; Xu Min; Gong Jianping

    2004-01-01

    Objective: To evaluate value of CT measurement and calculation of vessels of isolate pig lung, by compare with measurement and calculation of resin cast of them. Methods: CT scanned and measured the four isolated pig lung which vessels were full with ABS liquid or self-solidification resin liquid, and calculate the relative ratio of superior/inferior order and vein/artery of same order. After resin cast were made, measure and calculate the same as CT did. Results: Second order of calculation of vein/artery of same order by the two method had statistic difference (P 0.05). Conclusion: CT has high value in calculation of the relative ratio of superior/inferior order

  1. Tolerance analysis in manufacturing using process capability ratio with measurement uncertainty

    DEFF Research Database (Denmark)

    Mahshid, Rasoul; Mansourvar, Zahra; Hansen, Hans Nørgaard

    2017-01-01

    . In this paper, a new statistical analysis was applied to manufactured products to assess achieved tolerances when the process is known while using capability ratio and expanded uncertainty. The analysis has benefits for process planning, determining actual precision limits, process optimization, troubleshoot......Tolerance analysis provides valuable information regarding performance of manufacturing process. It allows determining the maximum possible variation of a quality feature in production. Previous researches have focused on application of tolerance analysis to the design of mechanical assemblies...... malfunctioning existing part. The capability measure is based on a number of measurements performed on part’s quality variable. Since the ratio relies on measurements, elimination of any possible error has notable negative impact on results. Therefore, measurement uncertainty was used in combination with process...

  2. The measurement and interpretation of Ne VII spectral line intensity ratios

    International Nuclear Information System (INIS)

    Lang, J.

    1983-03-01

    Results are presented for the measurement, using the branching ratios calibration method, of the spectral intensities of Ne VII lines emitted from a theta-pinch plasma whose electron temperature and density have been found by laser scattering and alternate techniques. (author)

  3. Measurement of signal-to-noise ratio performance of TV fluoroscopy systems

    International Nuclear Information System (INIS)

    Geluk, R.J.

    1985-01-01

    A method has been developed for direct measurement of Signal-to-Noise ratio performance on X-ray TV systems. To this end the TV signal resulting from a calibrated test object, is compared with the noise level in the image. The method is objective and produces instantaneous readout, which makes it very suitable for system evaluation under dynamic conditions. (author)

  4. High-precision branching-ratio measurement for the superallowed β+ emitter 74Rb

    Science.gov (United States)

    Dunlop, R.; Ball, G. C.; Leslie, J. R.; Svensson, C. E.; Towner, I. S.; Andreoiu, C.; Chagnon-Lessard, S.; Chester, A.; Cross, D. S.; Finlay, P.; Garnsworthy, A. B.; Garrett, P. E.; Glister, J.; Hackman, G.; Hadinia, B.; Leach, K. G.; Rand, E. T.; Starosta, K.; Tardiff, E. R.; Triambak, S.; Williams, S. J.; Wong, J.; Yates, S. W.; Zganjar, E. F.

    2013-10-01

    A high-precision branching-ratio measurement for the superallowed β+ decay of 74Rb was performed at the TRIUMF Isotope Separator and Accelerator (ISAC) radioactive ion-beam facility. The scintillating electron-positron tagging array (SCEPTAR), composed of 10 thin plastic scintillators, was used to detect the emitted β particles; the 8π spectrometer, an array of 20 Compton-suppressed HPGe detectors, was used for detecting γ rays that were emitted following Gamow-Teller and nonanalog Fermi β+ decays of 74Rb; and the Pentagonal Array of Conversion Electron Spectrometers (PACES), an array of 5 Si(Li) detectors, was employed for measuring β-delayed conversion electrons. Twenty-three excited states were identified in 74Kr following 8.241(4)×108 detected 74Rb β decays. A total of 58 γ-ray and electron transitions were placed in the decay scheme, allowing the superallowed branching ratio to be determined as B0=99.545(31)%. Combined with previous half-life and Q-value measurements, the superallowed branching ratio measured in this work leads to a superallowed ft value of 3082.8(65) s. Comparisons between this superallowed ft value and the world-average-corrected Ft¯ value, as well as the nonanalog Fermi branching ratios determined in this work, provide guidance for theoretical models of the isospin-symmetry-breaking corrections in this mass region.

  5. Technical note: using Distributed Temperature Sensing for Bowen ratio evaporation measurements

    NARCIS (Netherlands)

    Schilperoort, B.; Coenders, Miriam; Luxemburg, W.M.J.; Jimenez Rodriguez, C.D.; Cisneros Vaca2, C.; Savenije, Hubert

    2017-01-01

    Rapid improvements in the precision and spatial resolution of Distributed Temperature Sensing (DTS) technology now allows its use in hydrological and atmospheric sciences. Introduced by Euser [Hydrol. Earth Syst. Sci., 18, 2021–2032 (2014)] is the use of DTS for measuring the Bowen ratio (BR-DTS),

  6. Measurement of stable isotope ratio of organic carbon in water samples

    International Nuclear Information System (INIS)

    Fujii, Toshihiro; Otsuki, Akira

    1977-01-01

    A new method for the measurement of stable isotope ratios was investigated and applied to organic carbon's isotope ratio measurements in water samples. A few river water samples from Tsuchiura city were tested. After the wet oxidation of organic carbons to carbon dioxide in a sealed ampoule, the isotope ratios were determined with the gas chromatograph-quadrupole mass spectrometer combined with a total organic carbon analyser, under the dynamic conditions. The GC-MS had been equipped with the multiple ion detector-digital integrator system. The ion intensities at m/e 44 and 45 were simultaneously measured at a switching rate of 1 ms. The measurements with carbon dioxide acquired from sodium carbonate (53 μg) gave the isotope ratios with the variation coefficient of 0.62%. However, the variation coefficients obtained from organic carbons in natural water samples were 2 to 3 times as high as that from sodium carbonate. This method is simple and rapid and may be applied to various fields especially in biology and medicine. (auth.)

  7. Sacroiliac Joint/Sacrum Uptake Ratio Measured by Quantitative Sacroiliac Joint Scintigraphy

    International Nuclear Information System (INIS)

    Lee, Young Yiul; Park, Seon Yang; Lee, Myung Chul; Choi, Sang Jae; Cho, Bo Youn; Choe, Kang Won; Koh, Chang Soon

    1982-01-01

    To evaluate the diagnostic usefulness and significance of quantitative sacroiliac joint scintigraphy in the assessment of sacroiliitis, we measured Sacroiliac Joint/Sacrum Uptake Ratio (SIS Ratio) by region of interest (ROI) method using 99m Tc-methylene diphosphonate. The observed results were as follows:1) Using ROI method, the SIS ratios for the control group of 65 persons were 1.05±0.08 (left) and 1.06±0.07 (right) which were narrower in range than those of slice method (mean±S.D.) 2) The effects of age, gender and laterality on SIS ratio were not significant. 3) In left side, one of 6 patients with rheumatoid arthritis had SIS ratio in excess of 2 standard deviation of normal control group, and remainder had SIS ratios within normal limit. In right side, 3 patients had SIS ratios in excess of 2 standard deviation of normal control group, and remainder, within normal limit. 4) In both sacroiliac joint, 2 of 3 patients having sacroiliitis clinically with Reiter's syndrome whose pelvis A-P X-ray findings showed normal had high SIS ratios (left/right; 1.31/1.69, 1.90/1.80), but SIS ratio of one patient who bad no evidence of sacroiliitis clinically was within normal limit. 5) In 6 patients with ankylosing spondylitis in both sacroiliac joints, q whose pelvis A-P X-ray findings showed severe sclerotic change of sacroiliac pints had SIS ratio within normal limit or below that of normal control group, and SIS ratios of 2 patients whose pelvis A-P X-ray findings showed were increased. 6) 4 of 5 patients with low back pain of which cause could not be evaluated clinically and radiologically had SIS ratios in excess of that of normal control group. It would be concluded the quantitative sacroiliac joint scintigraphy is useful and sensitive screening method in the diagnosis as well as in the assessment clinical activity of sacroiliitis.

  8. An impedance bridge measuring the capacitance ratio in the high frequency range up to 1 MHz

    International Nuclear Information System (INIS)

    Kim, Dan Bee; Lee, Hyung Kew; Kim, Wan-Seop

    2017-01-01

    This paper describes a 2-terminal-pair impedance bridge, measuring the capacitance ratio in the high frequency range up to 1 MHz. The bridge was configured with two voltage sources and a phase control unit which enabled the bridge balance by synchronizing the voltage sources with an enhanced phase resolution. Without employing the transformers such as inductive voltage divider, injection and detection transformers, etc, the bridge system is quite simple to set up, and the balance procedure is quick and easy. Using this dual-source coaxial bridge, the 1:1 and 10:1 capacitance ratios were measured with 1 pF–1 nF capacitors in the frequency range from 1 kHz to 1 MHz. The measurement values obtained by the dual-source bridge were then compared with reference values measured using a commercial precision capacitance bridge of AH2700A, the Z -matrix method developed by ourselves, and the 4-terminal-pair coaxial bridge by the Czech Metrological Institute. All the measurements agreed within the reference uncertainty range of an order of 10 −6 –10 −5 , proving the bridge ability as a trustworthy tool for measuring the capacitance ratio in the high frequency range. (paper)

  9. Stochastic Dominance and Omega Ratio: Measures to Examine Market Efficiency, Arbitrage Opportunity, and Anomaly

    Directory of Open Access Journals (Sweden)

    Xu Guo

    2017-10-01

    Full Text Available Both stochastic dominance and Omegaratio can be used to examine whether the market is efficient, whether there is any arbitrage opportunity in the market and whether there is any anomaly in the market. In this paper, we first study the relationship between stochastic dominance and the Omega ratio. We find that second-order stochastic dominance (SD and/or second-order risk-seeking SD (RSD alone for any two prospects is not sufficient to imply Omega ratio dominance insofar that the Omega ratio of one asset is always greater than that of the other one. We extend the theory of risk measures by proving that the preference of second-order SD implies the preference of the corresponding Omega ratios only when the return threshold is less than the mean of the higher return asset. On the other hand, the preference of the second-order RSD implies the preference of the corresponding Omega ratios only when the return threshold is larger than the mean of the smaller return asset. Nonetheless, first-order SD does imply Omega ratio dominance. Thereafter, we apply the theory developed in this paper to examine the relationship between property size and property investment in the Hong Kong real estate market. We conclude that the Hong Kong real estate market is not efficient and there are expected arbitrage opportunities and anomalies in the Hong Kong real estate market. Our findings are useful for investors and policy makers in real estate.

  10. Intercomparison of personal dose equivalent measurements by active personal dosimeters. Final report of a joint IAEA-EURADOS project

    International Nuclear Information System (INIS)

    2007-11-01

    standard laboratory. The final results, as assessed by the irradiation laboratories and discussed with the APD suppliers, were: - The general dosimetric performance of the tested APD is comparable with the performance of standard passive dosimetric systems; - The accuracy at reference photon radiation, the reproducibility and the repeatability of measurements are even better than for most passive dosimeters; - Only three devices have given satisfactory results both for 60 kV (RQR4) and for 120 kV (RQR9) pulsed radiation. Not all the devices have been designed for any radiation field and the end-user should at least take into account information about the dose equivalent rate and energy ranges before using the dosimeters. The performance results confirm that the IEC standard requirements are adequate but that they can be insufficient for some applications such as with pulsed radiation fields

  11. Temperature Measurements in the Solar Transition Region Using N III Line Intensity Ratios

    Science.gov (United States)

    Doron, R.; Doschek, G. A.; Laming, J. M.; Feldman, U.; Bhatia, A. K.

    2003-01-01

    UV emission from B-like N and O ions a rather rare opportunity for recording spectral lines in a narrow wavelength range that can potentially be used to derive temperatures relevant to the solar transition region. In these ions, the line intensity ratios of the type (2s2p(sup 2) - 2p(sup 3)) / (2s(sup 2)2p - 2s2p(sup 2)) are very sensitive to the electron temperature. Additionally, the lines involving the ratios fall within a range of only - 12 A; in N III the lines fall in the 980 - 992 A range and in O IV in the 780 - 791 A range. In this work, we explore the use of these atomic systems, primarily in N III, for temperature diagnostics of the transition region by analyzing UV spectra obtained by the Solar Ultraviolet Measurements of Emitted Radiation (SUMER) spectrometer flown on the Solar and Heliospheric Observatory (SOHO). The N III temperature-sensitive line ratios are measured in more than 60 observations. Most of the measured ratios correspond to temperatures in the range 5.7x10(exp 4) - 6.7x10(exp 4) K. This range is considerably lower than the calculated temperature of maximum abundance of N III, which is approx. 7.6x10(exp 4) K. Detailed analysis of the spectra further indicates that the measured ratios are probably somewhat overestimated due to resonant scattering effects in the 2s(sup 2)2p - 2s2p(sup 2) lines and small blends in the 2s2p(sup 2) - 2p3 lines. Actual lower ratios would only increase the disagreement between the ionization balance calculations and present temperature measurements based on a collisional excitation model. In the case of the O IV spectra, we determined that due to the close proximity in wavelength of the weak line (2s2p(sup 2)-2p3 transitions) to a strong Ne VIII line, sufficiently accurate ratio measurements cannot be obtained. Subject headings: atomic data --- atomic processes --- Sun: transition region --- Sun: U V radiation --- techniques: spectroscopic

  12. Design and Analyses of High Aspect Ratio Nozzles for Distributed Propulsion Acoustic Measurements

    Science.gov (United States)

    Dippold, Vance F., III

    2016-01-01

    A series of three convergent round-to-rectangular high-aspect ratio nozzles were designed for acoustics measurements. The nozzles have exit area aspect ratios of 8:1, 12:1, and 16:1. With septa inserts, these nozzles will mimic an array of distributed propulsion system nozzles, as found on hybrid wing-body aircraft concepts. Analyses were performed for the three nozzle designs and showed that the flow through the nozzles was free of separated flow and shocks. The exit flow was mostly uniform with the exception of a pair of vortices at each span-wise end of the nozzle.

  13. High-precision branching-ratio measurement for the superallowed β+ emitter 26Alm

    Science.gov (United States)

    Finlay, P.; Ball, G. C.; Leslie, J. R.; Svensson, C. E.; Andreoiu, C.; Austin, R. A. E.; Bandyopadhyay, D.; Cross, D. S.; Demand, G.; Djongolov, M.; Ettenauer, S.; Garrett, P. E.; Green, K. L.; Grinyer, G. F.; Hackman, G.; Leach, K. G.; Pearson, C. J.; Phillips, A. A.; Rand, E. T.; Sumithrarachchi, C. S.; Triambak, S.; Williams, S. J.

    2012-05-01

    A high-precision branching-ratio measurement for the superallowed β+ emitter 26Alm was performed at the TRIUMF-ISAC radioactive ion beam facility. An upper limit of ⩽12 ppm at 90% confidence level was found for the second forbidden β+ decay of 26Alm to the 21+ state at 1809 keV in 26Mg. An inclusive upper limit of ⩽15 ppm at 90% confidence level was found when considering all possible nonanalog β+/EC decay branches of 26Alm, resulting in a superallowed branching ratio of 100.0000-0.0015+0%.

  14. Measurement of the cosmic ray muon charge ratio with the OPERA detector

    OpenAIRE

    Mauri, N; Siol, M

    2010-01-01

    The OPERA detector at the Gran Sasso underground laboratory (LNGS) was used to measure the cosmic ray muon charge ratio Rμ = Nμ+/Nμ− in the TeV energy region. We analyzed 403069 cosmic ray muons corresponding to 113.4 days of livetime during the 2008 CNGS run. We computed separately the muon charge ratio for single and for multiple muon events in order to select different energy regions of the primary cosmic ray spectrum and to test the Rμ dependence on the primary composition. Rμ is also sho...

  15. Measurement of lime/silica ratio in concrete using PGNAA technique

    Energy Technology Data Exchange (ETDEWEB)

    Naqvi, A.A. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)]. E-mail: aanaqvi@kfupm.edu.sa; Nagadi, M.M. [Department of Physics, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia); Al-Amoudi, O.S.B. [Department of Civil Engineering, King Fahd University of Petroleum and Minerals, Dhahran 31261 (Saudi Arabia)

    2005-12-01

    Prompt gamma neutron activation analysis (PGNAA) technique has been used to determine lime/silica ratio in concrete samples using an accelerator-based PGNAA facility. The ratio was determined from the measured yield of 6.42 MeV prompt {gamma}-rays of calcium and 4.93 MeV {gamma}-rays of silicon from the six concrete samples. The experimental results were compared with the results of the Monte Carlo simulations. An excellent agreement has been achieved between the two. The study has demonstrated successful use of the accelerator-based PGNAA setup in non-destructive analysis of the concrete samples.

  16. The fast ratio: A rapid measure for testing the dominance of the fast component in the initial OSL signal from quartz

    International Nuclear Information System (INIS)

    Durcan, Julie A.; Duller, Geoff A.T.

    2011-01-01

    The signal from the fast component is usually considered preferable for quartz optically stimulated luminescence (OSL) dating, however its presence in a continuous wave (CW) OSL signal is often assumed, rather than verified. This paper presents an objective measure (termed the fast ratio) for testing the dominance of the fast component in the initial part of a quartz OSL signal. The ratio is based upon the photo ionisation cross-sections of the fast and medium components and the power of the measurement equipment used to record the OSL signal, and it compares parts of the OSL signal selected to represent the fast and medium components. The ability of the fast ratio to distinguish between samples whose CW-OSL signal is dominated by the fast and non-fast components is demonstrated by comparing the fast ratio with the contribution of the fast component calculated from curve deconvolution of measured OSL signals and from simulated data. The ratio offers a rapid method for screening a large number of OSL signals obtained for individual equivalent dose estimates, it can be calculated and applied as easily as other routine screening methods, and is transferrable between different aliquots, samples and measurement equipment. - Highlights: → Fast ratio is a measure which tests dominance of fast component in quartz OSL signals. → A fast ratio above 20 implies a CW-OSL signal is dominated by fast component. → Fast ratio can be easily and rapidly applied to a large number of OSL signals. → Uses include signal comparison, data screening, identify need for further analysis.

  17. The Measurement of Fuel-Air Ratio by Analysis for the Oxidized Exhaust Gas

    Science.gov (United States)

    Gerrish, Harold C.; Meem, J. Lawrence, Jr.

    1943-01-01

    An investigation was made to determine a method of measuring fuel-air ratio that could be used for test purposes in flight and for checking conventional equipment in the laboratory. Two single-cylinder test engines equipped with typical commercial engine cylinders were used. The fuel-air ratio of the mixture delivered to the engines was determined by direct measurement of the quantity of air and of fuel supplied and also by analysis of the oxidized exhaust gas and of the normal exhaust gas. Five fuels were used: gasoline that complied with Army-Navy fuel Specification No. AN-VV-F-781 and four mixtures of this gasoline with toluene, benzene, and xylene. The method of determining the fuel-air ratio described in this report involves the measurement of the carbon-dioxide content of the oxidized exhaust gas and the use of graphs for the presented equation. This method is considered useful in aircraft, in the field, or in the laboratory for a range of fuel-air ratios from 0.047 to 0.124.

  18. The Measurement of Fuel-air Ratio by Analysis of the Oxidized Exhaust Gas

    Science.gov (United States)

    Memm, J. Lawrence, Jr.

    1943-01-01

    An investigation was made to determine a method of measuring fuel-air ratio that could be used for test purposes in flight and for checking conventional equipment in the laboratory. Two single-cylinder test engines equipped with typical commercial engine cylinders were used. The fuel-air ratio of the mixture delivered to the engines was determined by direct measurement of the quantity of air and of fuel supplied and also by analysis of the oxidized exhaust gas and of the normal exhaust gas. Five fuels were used: gasoline that complied with Army-Navy Fuel Specification, No. AN-VV-F-781 and four mixtures of this gasoline with toluene, benzene, and xylene. The method of determining the fuel-air ratio described in this report involves the measurement of the carbon-dioxide content of the oxidized exhaust gas and the use of graphs or the presented equation. This method is considered useful in aircraft, in the field, or in the laboratory for a range of fuel-air ratios from 0.047 to 0.124

  19. High Precision Measurement of the Proton Elastic Form Factor Ratio at Low Q2

    Energy Technology Data Exchange (ETDEWEB)

    Xiaohui Zhan

    2009-12-01

    A high precision measurement of the proton elastic form factor ratio µpGEp/GMp in the range Q2 = 0.3–0.7 GeV2/c2 was performed using recoil polarimetry in Jefferson Lab Hall A. In this low Q2 range, previous data from LEDEX [5] along with many fits and calculations [2, 3, 4] indicate substantial deviations of the ratio from unity. In this new measurement, with 80% polarized electron beam for 24 days, we are able to achieve <1% statistical uncertainty. Preliminary results are a few percent lower than expected from previous world data and fits, indicating a smaller GEp at this region. Beyond the intrinsic interest in nucleon structure, the improved form factor measurements also have implications for DVCS, determinations of the proton Zemach radius and strangeness form factors through parity violation experiments.

  20. Measurement of the Ratio of the B-0 -> D*(-)iota(+)v(iota) and B-0 -> D*(-) mu(+)v(mu) Branching Fractions Using Three-Prong tau-Lepton Decays

    NARCIS (Netherlands)

    Aaij, R.; Adeva, B.; Adinolfi, M.; Ajaltouni, Z.; Akar, S.; Albrecht, J.; Alessio, F.; Dufour, L.; Mulder, M; Onderwater, C. J. G.; Pellegrino, A.; Tolk, S.; van Veghel, M.

    2018-01-01

    The ratio of branching fractions R(D*(-)) equivalent to B(B-0 -> D*(-) iota(+)v(iota))/B(B-0 -> D*(-) mu+ v(mu)) is measured using a data sample of proton-proton collisions collected with the LHCb detector at center-of-mass energies of 7 and 8 TeV, corresponding to an integrated luminosity of 3

  1. Applicability of an improved Trolox equivalent antioxidant capacity (TEAC) assay for evaluation of antioxidant capacity measurements of mixtures

    NARCIS (Netherlands)

    Berg, R. van den; Haenen, G.R.M.M.; Berg, H. van den; Bast, A.

    1999-01-01

    The TEAC (Trolox equivalent antioxidant capacity) assay is based on scavenging of 2,2'-azinobis-(3- ethylbenzothiazoline-6-sulfonate) radical anions (ABTS(.-)). In this report we describe a modification based on pre-generation of the ABTS radical anions with a thermolabile azo compound, 2,2'-azobis-

  2. Measuring Child Poverty in South Africa: Sensitivity to the Choice of Equivalence Scale and an Updated Profile

    Science.gov (United States)

    Streak, Judith Christine; Yu, Derek; Van der Berg, Servaas

    2009-01-01

    This paper offers evidence on the sensitivity of child poverty in South Africa to changes in the adult equivalence scale (AES) and updates the child poverty profile based on the Income and Expenditure Survey 2005/06. Setting the poverty line at the 40th percentile of households calculated with different AESs the scope and composition of child…

  3. Performance tests and comparison of microdosimetric measurements with four tissue-equivalent proportional counters in scanning proton therapy

    Czech Academy of Sciences Publication Activity Database

    Farah, J.; De Saint-Hubert, M.; Mojzeszek, N.; Chiriotti, S.; Gryzinski, M.; Ploc, Ondřej; Trompier, F.; Turek, Karel; Vanhavere, F.; Olko, P.

    2017-01-01

    Roč. 96, JAN (2017), s. 42-52 ISSN 1350-4487 EU Projects: European Commission(XE) 662287 - CONCERT Institutional support: RVO:61389005 Keywords : tissue-equivalent proportional counters * microdosimetry * proton therapy * stray neutrons and prothons Subject RIV: JF - Nuclear Energetics OBOR OECD: Nuclear related engineering Impact factor: 1.442, year: 2016

  4. An appraisal of subcooled boiling and slip ratio from measurements made in Lingen BWR

    International Nuclear Information System (INIS)

    Nash, G.

    1977-08-01

    Measurements of steam bubble velocities and voidage have been made in the relatively small Core B of Lingen BWR. The results of axial scanning in one radial position have produced experimental values of slip ratio, power (from a travelling incore probe), voidage and coolant mean density over the core height for this position. This one set of distributions has enabled us to test current UKAEA models of subcooled boiling and slip ratio against experiment. From the comparisons, it appears that we can predict the onset of voiding well, but the assumption that a constant fraction of the heat flux forms steam in the subcooled region needs modifying. Of four slip options tested, the current one used by HAMBO and JOSHUA III (Bankoff-Jones) predicts too high a slip ratio. A closer fit to experiment comes from the new Bryce flow-dependent slip option. Any changes in the modelling must be checked, however, with coupled thermal hydraulics-neutronics computations. (author)

  5. Measurement of the cosmic ray muon charge ratio with the OPERA detector

    CERN Document Server

    Mauri, N

    2010-01-01

    The OPERA detector at the Gran Sasso underground laboratory (LNGS) was used to measure the cosmic ray muon charge ratio Rμ = Nμ+/Nμ− in the TeV energy region. We analyzed 403069 cosmic ray muons corresponding to 113.4 days of livetime during the 2008 CNGS run. We computed separately the muon charge ratio for single and for multiple muon events in order to select different energy regions of the primary cosmic ray spectrum and to test the Rμ dependence on the primary composition. Rμ is also shown as a function of the Òvertical surface energyÓ Eμ cos !. A Þt to a simpliÞed model of muon pro- duction in atmosphere allowed the determination of the pion and kaon charge ratios weighted by the cosmic ray energy spectrum.

  6. The Role of Equivalence and Order Relations in the Development and Coordination of the Concepts of Unit Size and Number of Units in Selected Conservation Type Measurement Problems.

    Science.gov (United States)

    Carpenter, Thomas P.

    The major purpose of this study was 1) to investigate the development of the concept of a unit of measure and the coordination of unit size and the number of units 2) to relate this development to the development of conservation and 3) to determine the role of equivalence and nonequivalence relations in certain conservation and measurement…

  7. On-line component ratio measurement of oil/gas/water mixtures using an admittance sensor

    Energy Technology Data Exchange (ETDEWEB)

    Andersen, J A

    1984-01-01

    The operator of a production platform is primarily interested in which types of fluids a well is producing and how quickly these different components are being produced. The component ratio and production rate of a well vary during the life of a field. To optimize production, measurement of each well's output is thus desirable. Current designs for subsea production systems lack means of continuously measuring three-component flows. A new method of component ratio measurement is described. The fraction of oil, gas and water flowing between two insulated electrode plates is determined by measuring both the electrical conductance and suseptance across the sensor. A preliminary evaluation of the new measurement system has been performed using a process oil/ water/air mixture. The method is not limited to small pipe diameters. The only possible limitation is that for low velocities in very large pipe diameters an in-line mixer may be required. Advantages of this new system are that real-time measurement of void fraction and water content is possible if a non-intrusive rugged sensor is used, and there are no range limitations, as each component may be measured for any given concentration. 4 references.

  8. Gross Motor Function Measure Evolution Ratio: Use as a Control for Natural Progression in Cerebral Palsy.

    Science.gov (United States)

    Marois, Pierre; Marois, Mikael; Pouliot-Laforte, Annie; Vanasse, Michel; Lambert, Jean; Ballaz, Laurent

    2016-05-01

    To develop a new way to interpret Gross Motor Function Measure (GMFM-66) score improvement in studies conducted without control groups in children with cerebral palsy (CP). The curves, which describe the pattern of motor development according to the children's Gross Motor Function Classification System level, were used as historical control to define the GMFM-66 expected natural evolution in children with CP. These curves have been modeled and generalized to fit the curve to particular children characteristics. Research center. Not applicable. Not applicable. Not applicable. Assuming that the GMFM-66 score evolution followed the shape of the Rosenbaum curves, by taking into account the age and GMFM-66 score of children, the expected natural evolution of the GMFM-66 score was predicted for any group of children with CP who were Ratio, was defined as follows: Gross Motor Function Measure Evolution Ratio=measured GMFM-66 score change/expected natural evolution. For practical or ethical reasons, it is almost impossible to use control groups in studies evaluating effectiveness of many therapeutic modalities. The Gross Motor Function Measure Evolution Ratio gives the opportunity to take into account the expected natural evolution of the gross motor function of children with CP, which is essential to accurately interpret the therapy effect on the GMFM-66. Copyright © 2016 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  9. Measurement of the ratio h / e with a photomultiplier tube and a set of LEDs

    International Nuclear Information System (INIS)

    Loparco, F; Malagoli, M S; Rainò, S; Spinelli, P

    2017-01-01

    We propose a laboratory experience aimed at undergraduate physics students to understand the main features of the photoelectric effect and to perform a measurement of the ratio h / e , where h is Planck’s constant and e is the electron charge. The experience is based on the method developed by Millikan for his measurements of the photoelectric effect in the years from 1912 to 1915. The experimental setup consists of a photomultiplier tube (PMT) equipped with a voltage divider properly modified to set variable retarding potentials between the photocathode and the first dynode, and a set of LEDs emitting at different wavelengths. The photocathode is illuminated with the various LEDs and, for each wavelength of the incident light, the output anode current is measured as a function of the retarding potential applied between the cathode and the first dynode. From each measurement, a value of the stopping potential for the anode current is derived. Finally, the stopping potentials are plotted as a function of the frequency of the incident light, and a linear fit is performed. The slope and the intercept of the line allow one to respectively evaluate the ratio h / e and the ratio W / e , where W is the work function of the photocathode. (paper)

  10. Simulation and Measurement of Neuroelectrodes' Characteristics with Integrated High Aspect Ratio Nano Structures

    Directory of Open Access Journals (Sweden)

    Christoph Nick

    2015-07-01

    Full Text Available Improving the interface between electrodes and neurons has been the focus of research for the last decade. Neuroelectrodes should show small geometrical surface area and low impedance for measuring and high charge injection capacities for stimulation. Increasing the electrochemically active surface area by using nanoporous electrode material or by integrating nanostructures onto planar electrodes is a common approach to improve this interface. In this paper a simulation approach for neuro electrodes' characteristics with integrated high aspect ratio nano structures based on a point-contact-model is presented. The results are compared with experimental findings conducted with real nanostructured microelectrodes. In particular, effects of carbon nanotubes and gold nanowires integrated onto microelectrodes are described. Simulated and measured impedance properties are presented and its effects onto the transfer function between the neural membrane potential and the amplifier output signal are studied based on the point-contact-model. Simulations show, in good agreement with experimental results, that electrode impedances can be dramatically reduced by the integration of high aspect ratio nanostructures such as gold nanowires and carbon nanotubes. This lowers thermal noise and improves the signal-to-noise ratio for measuring electrodes. It also may increase the adhesion of cells to the substrate and thus increase measurable signal amplitudes.

  11. Basic study of water-cement ratio evaluation for fresh mortar using an ultrasonic measurement technique

    International Nuclear Information System (INIS)

    Hamza Haffies Ismail; Murata, Yorinobu

    2009-01-01

    The objective of this research is for the basic study of ultrasonic evaluation method for the determination of the water-cement-ratio (W/C) in fresh concrete at the early age of hardening. Water-cement ratio is a important parameter to evaluate the strength of concrete for concrete construction. Using an ultrasonic pulse measurement technique, wave velocity and frequency variations depend on the age of concrete during hardening process could be evaluated. As a sample test, fresh mortar of water-cement ratio of 40 %, 50% and 60 % was poured into cylindrical plastic mould form (φ100 mm x 50 mm). For an ultrasonic pulse wave transmission technique, two wide band ultrasonic transducers were set on the top and bottom surface of mortar, and start measuring from 10 minutes after pouring water until 60 minutes of 5 minutes of intervals. As a result, it was confirmed that wave velocity and center frequency were changed with the age of mortar depends on the water-cement ratio. (author)

  12. Neutron spectrometer for DD/DT burning ratio measurement in fusion experimental reactor

    International Nuclear Information System (INIS)

    Asai, Keisuke; Naoi, Norihiro; Iguchi, Tetsuo; Watanabe, Kenichi; Kawarabayashi, Jun; Nishitani, Takeo

    2006-01-01

    The most feasible fuels for a fusion reactor are D (Deuterium) and T (Tritium). DD and/or DT fusion reaction or nuclear burning reaction provides two kinds of neutrons, DD neutron and DT neutron, respectively. DD/DT burning ratio, which can be estimated by DD/DT neutron ratio in the burning plasma, is essential for burn control, alpha particle emission rate monitoring and tritium fuel cycle estimation. Here we propose a new neutron spectrometer for the absolute DD/DT burning ratio measurement. The system consists of a Proton Recoil Telescope (PRT) and a Time-of-Flight (TOF) technique. We have conducted preliminary experiments with a prototype detector and a DT neutron beam (φ20 mm) at the Fusion Neutronics Source, Japan Atomic Energy Agency (JAEA), to assess its basic performance. The detection efficiency obtained by the experiment is consistent with the calculation results in PRT, and sufficient energy resolution for the DD/DT neutron discrimination has been achieved in PRT and TOF. The validity of the Monte Carlo calculation has also been confirmed by comparing the experimental results with the calculation results. The design consideration of this system for use in ITER (International Thermonuclear Experimental Reactor) has shown that this system is capable of monitoring the line-integrated DD/DT burning ratio for the plasma core line of sight with the required measurement accuracy of 20% in the upper 4 decades of the ITER operation (fusion power: 100 kW-700 MW). (author)

  13. Strain ratio measurement of femoral cartilage by real-time elastosonography: preliminary results

    International Nuclear Information System (INIS)

    Ipek, Ali; Unal, Ozlem; Kartal, Merve Gulbiz; Arslan, Halil; Isik, Cetin; Bozkurt, Murat

    2015-01-01

    The purpose of this study was to evaluate strain ratio measurement of femoral cartilage using real-time elastosonography. Twenty-five patients with femoral cartilage pathology on MRI (study group) were prospectively compared with 25 subjects with normal findings on MRI (control group) using real-time elastosonography. Strain ratio measurements of pathologic and normal cartilage were performed and compared, both within the study group and between the two groups. Elastosonography colour-scale coding showed a colour change from blue to red in pathologic cartilage and only blue colour-coding in normal cartilage. In the study group, the median strain ratio was higher in pathologic cartilage areas compared to normal areas (median, 1.49 [interquartile range, 0.80-2.53] vs. median, 0.01 [interquartile range, 0.01-0.01], p < 0.001, respectively). The median strain ratio of the control group was 0.01 (interquartile range, 0.01-0.01), and there was no significant difference compared to normal areas of the study group. There was, however, a significant difference between the control group cartilage and pathologic cartilage of the study group (p < 0.001). Elastosonography may be an effective, easily accessible, and relatively simple tool to demonstrate pathologic cartilage and to differentiate it from normal cartilage in the absence of advanced imaging facility such as MRI. (orig.)

  14. A measurement of the branching ratio for the Σ+ → pγ decay

    International Nuclear Information System (INIS)

    Hessey, N.P.; Lowe, J.; Booth, E.C.; Gall, K.P.; McIntyre, E.K.; Miller, J.P.; Roberts, B.L.; Whitehouse, D.A.; Fickinger, W.J.; Robinson, D.K.; Hasinoff, M.D.; Measday, D.F.; Noble, A.J.; Horvath, D.; Salomon, M.

    1989-01-01

    We have measured the weak radiative decay branching ratio (Σ + → pγ)/(Σ + → pπ 0 ). The experiment was carried out at Brookhaven National Laboratory using a low-energy separated K - beam stopping in liquid hydrogen. The Σ + was tagged by observing the pion from K - p → Σ + π - in a range telescope, and the gamma was detected in a segmented NaI detector. The result is (2.81 ± 0.39 +0.21 0.43 ) x 10 -3 , which is consistent with previous measurements. This corresponds to a branching ratio for (Σ + → pγ)/(Σ + → all) of (1.45 ± 0.20 +0.11 0.22 ) x 10 -3 , where the quoted errors are statistical and systematic, respectively. A total of 408 signal events were observed, doubling the previous world total. (orig.)

  15. Generalized weighted ratio method for accurate turbidity measurement over a wide range.

    Science.gov (United States)

    Liu, Hongbo; Yang, Ping; Song, Hong; Guo, Yilu; Zhan, Shuyue; Huang, Hui; Wang, Hangzhou; Tao, Bangyi; Mu, Quanquan; Xu, Jing; Li, Dejun; Chen, Ying

    2015-12-14

    Turbidity measurement is important for water quality assessment, food safety, medicine, ocean monitoring, etc. In this paper, a method that accurately estimates the turbidity over a wide range is proposed, where the turbidity of the sample is represented as a weighted ratio of the scattered light intensities at a series of angles. An improvement in the accuracy is achieved by expanding the structure of the ratio function, thus adding more flexibility to the turbidity-intensity fitting. Experiments have been carried out with an 850 nm laser and a power meter fixed on a turntable to measure the light intensity at different angles. The results show that the relative estimation error of the proposed method is 0.58% on average for a four-angle intensity combination for all test samples with a turbidity ranging from 160 NTU to 4000 NTU.

  16. Stable Carbon Isotope Ratio (δ13C Measurement of Graphite Using EA-IRMS System

    Directory of Open Access Journals (Sweden)

    Andrius Garbaras

    2015-06-01

    Full Text Available δ13C values in non-irradiated natural graphite were measured. The measurements were carried out using an elemental analyzer combined with stable isotope ratio mass spectrometer (EA-IRMS. The samples were prepared with ground and non-ground graphite, the part of which was mixed with Mg (ClO42. The best combustion of graphite in the oxidation furnace of the elemental analyzer was achieved when the amount of pulverized graphite ranged from 200 to 490 µg and the mass ratio C:Mg(ClO42 was approximately 1:10. The method for the graphite burning avoiding the isotope fractionation is proposed.DOI: http://dx.doi.org/10.5755/j01.ms.21.2.6873

  17. Measurement and application of purine derivatives: Creatinine ratio in spot urine samples of ruminants

    International Nuclear Information System (INIS)

    Chen, X.B.; Jayasuriya, M.C.N.; Makkar, H.P.S.

    2004-01-01

    The daily excretion of purine derivatives in urine has been used to estimate the supply of microbial protein to ruminant animals. The method provides a simple and non-invasive tool to indicate the nutritional status of farm animals. However due to the need for complete collection of urine the potential application at farm level is restricted. Research conducted under the FAO/IAEA Co-ordinated Research Project has indicated that it is possible to use the purine derivatives:creatinine ratio measured in several spot urine samples collected within a day, as an index of microbial protein supply in a banding system for farm application. Some theoretical and experimental aspects in the measurement of purine derivatives:creatinine ratio in spot urine samples and the possible application of the banding system at the farm level are discussed. (author)

  18. Evaluating signal-to-noise ratios, loudness, and related measures as indicators of airborne sound insulation.

    Science.gov (United States)

    Park, H K; Bradley, J S

    2009-09-01

    Subjective ratings of the audibility, annoyance, and loudness of music and speech sounds transmitted through 20 different simulated walls were used to identify better single number ratings of airborne sound insulation. The first part of this research considered standard measures such as the sound transmission class the weighted sound reduction index (R(w)) and variations of these measures [H. K. Park and J. S. Bradley, J. Acoust. Soc. Am. 126, 208-219 (2009)]. This paper considers a number of other measures including signal-to-noise ratios related to the intelligibility of speech and measures related to the loudness of sounds. An exploration of the importance of the included frequencies showed that the optimum ranges of included frequencies were different for speech and music sounds. Measures related to speech intelligibility were useful indicators of responses to speech sounds but were not as successful for music sounds. A-weighted level differences, signal-to-noise ratios and an A-weighted sound transmission loss measure were good predictors of responses when the included frequencies were optimized for each type of sound. The addition of new spectrum adaptation terms to R(w) values were found to be the most practical approach for achieving more accurate predictions of subjective ratings of transmitted speech and music sounds.

  19. Quantitative stress measurement of elastic deformation using mechanoluminescent sensor: An intensity ratio model

    Science.gov (United States)

    Cai, Tao; Guo, Songtao; Li, Yongzeng; Peng, Di; Zhao, Xiaofeng; Liu, Yingzheng

    2018-04-01

    The mechanoluminescent (ML) sensor is a newly developed non-invasive technique for stress/strain measurement. However, its application has been mostly restricted to qualitative measurement due to the lack of a well-defined relationship between ML intensity and stress. To achieve accurate stress measurement, an intensity ratio model was proposed in this study to establish a quantitative relationship between the stress condition and its ML intensity in elastic deformation. To verify the proposed model, experiments were carried out on a ML measurement system using resin samples mixed with the sensor material SrAl2O4:Eu2+, Dy3+. The ML intensity ratio was found to be dependent on the applied stress and strain rate, and the relationship acquired from the experimental results agreed well with the proposed model. The current study provided a physical explanation for the relationship between ML intensity and its stress condition. The proposed model was applicable in various SrAl2O4:Eu2+, Dy3+-based ML measurement in elastic deformation, and could provide a useful reference for quantitative stress measurement using the ML sensor in general.

  20. Accurate branching ratio measurements in 23Na(p,γ)24Mg

    International Nuclear Information System (INIS)

    Boydell, S.G.; Sargood, D.G.

    1975-01-01

    The reaction 23 Na(p,γ) 24 Mg has been investigated in the proton energy range 0.3-1.75 MeV. Gamma ray spectra were measured for 22 resonances with Ge(Li) detectors which were carefully calibrated for relative peak efficiencies. Allowance was made for the effect of anisotropies in all the emitted γ-rays. The spectra have been analysed to give branching ratios for bound and unbound levels. (author)

  1. New measurement of BR(D→ρμν)BR(D→Kμν) branching ratio

    Science.gov (United States)

    FOCUS Collaboration; Link, J. M.; Yager, P. M.; Anjos, J. C.; Bediaga, I.; Castromonte, C.; Machado, A. A.; Magnin, J.; Massafferri, A.; de Miranda, J. M.; Pepe, I. M.; Polycarpo, E.; Dos Reis, A. C.; Carrillo, S.; Casimiro, E.; Cuautle, E.; Sánchez-Hernández, A.; Uribe, C.; Vá, F.; Agostino, L.; Cinquini, L.; Cumalat, J. P.; O'Reilly, B.; Segoni, I.; Stenson, K.; Butler, J. N.; Cheung, H. W. K.; Chiodini, G.; Gaines, I.; Garbincius, P. H.; Garren, L. A.; Gottschalk, E.; Kasper, P. H.; Kreymer, A. E.; Kutschke, R.; Wang, M.; Benussi, L.; Bertani, M.; Bianco, S.; Fabbri, F. L.; Pacetti, S.; Zallo, A.; Reyes, M.; Cawlfield, C.; Kim, D. Y.; Rahimi, A.; Wiss, J.; Gardner, R.; Kryemadhi, A.; Chung, Y. S.; Kang, J. S.; Ko, B. R.; Kwak, J. W.; Lee, K. B.; Cho, K.; Park, H.; Alimonti, G.; Barberis, S.; Boschini, M.; Cerutti, A.; D'Angelo, P.; Dicorato, M.; Dini, P.; Edera, L.; Erba, S.; Inzani, P.; Leveraro, F.; Malvezzi, S.; Menasce, D.; Mezzadri, M.; Moroni, L.; Pedrini, D.; Pontoglio, C.; Prelz, F.; Rovere, M.; Sala, S.; Davenport, T. F.; Arena, V.; Boca, G.; Bonomi, G.; Gianini, G.; Liguori, G.; Lopes Pegna, D.; Merlo, M. M.; Pantea, D.; Ratti, S. P.; Riccardi, C.; Vitulo, P.; Gö, C.; Otalora, J.; Hernandez, H.; Lopez, A. M.; Mendez, H.; Paris, A.; Quinones, J.; Ramirez, J. E.; Zhang, Y.; Wilson, J. R.; Handler, T.; Mitchell, R.; Engh, D.; Hosack, M.; Johns, W. E.; Luiggi, E.; Moore, J. E.; Nehring, M.; Sheldon, P. D.; Vaandering, E. W.; Webster, M.; Sheaff, M.

    2006-06-01

    Using data collected by the FOCUS experiment at Fermilab, we present a new measurement of the charm semileptonic branching ratio BR(D→ρμν)BR(D→Kμν). From a sample of 320±44 and 11372±161D→ρμν and D→Kπμν events respectively, we find BR(D→ρμν)BR(D→Kμν)=0.041±0.006 (stat)±0.004 (syst).

  2. Evaluating the reliability of uranium concentration and isotope ratio measurements via an interlaboratory comparison program

    International Nuclear Information System (INIS)

    Oliveira Junior, Olivio Pereira de; Oliveira, Inez Cristina de; Pereira, Marcia Regina; Tanabe, Eduardo

    2009-01-01

    The nuclear fuel cycle is a strategic area for the Brazilian development because it is associated with the generation of electricity needed to boost the country economy. Uranium is one the chemical elements in this cycle and its concentration and isotope composition must be accurately known. In this present work, the reliability of the uranium concentration and isotope ratio measurements carried out at the CTMSP analytical laboratories is evaluated by the results obtained in an international interlaboratory comparison program. (author)

  3. Measurement invariance within and between individuals: a distinct problem in testing the equivalence of intra- and inter-individual model structures.

    Science.gov (United States)

    Adolf, Janne; Schuurman, Noémi K; Borkenau, Peter; Borsboom, Denny; Dolan, Conor V

    2014-01-01

    We address the question of equivalence between modeling results obtained on intra-individual and inter-individual levels of psychometric analysis. Our focus is on the concept of measurement invariance and the role it may play in this context. We discuss this in general against the background of the latent variable paradigm, complemented by an operational demonstration in terms of a linear state-space model, i.e., a time series model with latent variables. Implemented in a multiple-occasion and multiple-subject setting, the model simultaneously accounts for intra-individual and inter-individual differences. We consider the conditions-in terms of invariance constraints-under which modeling results are generalizable (a) over time within subjects, (b) over subjects within occasions, and (c) over time and subjects simultaneously thus implying an equivalence-relationship between both dimensions. Since we distinguish the measurement model from the structural model governing relations between the latent variables of interest, we decompose the invariance constraints into those that involve structural parameters and those that involve measurement parameters and relate to measurement invariance. Within the resulting taxonomy of models, we show that, under the condition of measurement invariance over time and subjects, there exists a form of structural equivalence between levels of analysis that is distinct from full structural equivalence, i.e., ergodicity. We demonstrate how measurement invariance between and within subjects can be tested in the context of high-frequency repeated measures in personality research. Finally, we relate problems of measurement variance to problems of non-ergodicity as currently discussed and approached in the literature.

  4. Measurement of the ratio of hydrogen to deuterium at the KSTAR 2009 experimental campaign

    International Nuclear Information System (INIS)

    Kwak, Jong-Gu; Wang, Son Jong; Kim, Sun Ho; Park, Jae Min; Na, Hoon Kyun

    2010-01-01

    The control of the ratio of hydrogen to the deuterium is one of the very important issues for ion cyclotron range of frequency (ICRF) minority heating as well as the plasma wall interaction in the tokamak. The ratio of hydrogen to deuterium during the tokamak shot was deduced from the emission spectroscopy measurements during the KSTAR 2009 experimental campaign. Graphite tiles were used for the plasma facing components (PFCs) at KSTAR and its surface area exposed to the plasma was about 11 m 2 . The data showed that it remained as high as around 50% during the campaign period because graphite tiles were exposed to the air for about two months and the hydrogen contents at the tiles are not fully pumped out due to the lack of baking on the PFC in the 2009 campaign. The validation of the spectroscopy method was checked by using the Zeeman effects and the ratio of hydrogen to the deuterium is compared with results from the residual gas analysis. During the tokamak shot, the ratio is low below 10% initially and saturated after around 1 s. When there is a hydrogen injection to the vessel via ion cyclotron wall conditioning and the boronization process where the carbone is used, the ratio of the hydrogen to the deuterium is increased by up to 100% and it recovers to around 50% after one day of operation. However it does not decrease below 50% at the end of the experimental campaign. It was found that the full baking on the PFC (with a high temperature and sufficient vacuum pumping) is required for the ratio control which guarantees the efficient ICRF heating at the KSTAR 2010 experimental campaign.

  5. Optimising neutron polarizers--measuring the flipping ratio and related quantities

    CERN Document Server

    Goossens, D J

    2002-01-01

    The continuing development of gaseous spin polarized sup 3 He transmission filters for use as neutron polarizers makes the choice of optimum thickness for these filters an important consideration. The 'quality factors' derived for the optimisation of transmission filters for particular measurements are general to all neutron polarizers. In this work optimisation conditions for neutron polarizers are derived and discussed for the family of studies related to measuring the flipping ratio from samples. The application of the optimisation conditions to sup 3 He transmission filters and other types of neutron polarizers is discussed. Absolute comparisons are made between the effectiveness of different types of polarizers for this sort of work.

  6. Isotope ratio measurements of uranium by LA-HR-ICP-MS

    Energy Technology Data Exchange (ETDEWEB)

    Marin, Rafael C.; Sarkis, Jorge E.S., E-mail: rafael.marin@usp.b, E-mail: jesarkis@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    This work describes the utilization of Laser Ablation High Resolution Inductively Mass Spectrometry (LA-HR-ICP-MS) technique for the determination of uranium isotope composition in a UO{sub 2} pellet (CRM -125A) supplied and certified by the New Brunswick Laboratory (NBL). To carry out the adjustments of the parameters was used a glass standard NIST 610, supplied and certified by National Institute of Standards and Technology (NIST). The precision of the measurements were improved by adjusting the following parameters: RF power, laser beam diameter, defocusing of laser beam, laser energy, laser energy-density, auxiliary gas and sample gas. The measurements were performed on a continuous ablation with low energy density and defocusing, which demonstrated to be the optimum to reach the best signal stability. Isotope ratios, {sup 234}U/{sup 238}U, {sup 235}U/{sup 238}U and {sup 236}U/{sup 238}U were measured, reaching relative standard deviations (RSD) from 1.55% to 7.60%. The parameters which caused the greatest impact in order to improve the signal stability were RF power, defocusing and laser beam diameter. The results presented by the measurements revealed that the Laser ablation ICP-MS technique offers a rapid and accurate way to perform uranium isotope ratios without any sample preparation, since it allows carrying out the measurements straight on the sample, besides to preserve the testimony that is very important for safeguards and nuclear forensics purposes. (author)

  7. Differential Drell-Yan measurements and Z/top-pair cross section ratios

    CERN Document Server

    Zinser, Markus; The ATLAS collaboration

    2017-01-01

    Precision measurements of the Drell-Yan production of W and Z bosons at the LHC provide a benchmark of our understanding of perturbative QCD and electroweak processes and probe the proton structure in a unique way. The ATLAS collaboration performed a precision Z/gamma* measurement at a center of mass energy of 8 TeV in the di-lepton mass range up to the TeV scale. These are performed double-differentially in dilepton mass and rapidity or dilepton mass and rapidity separation. The measurements are compared to state-of-the-art theory calculations and are found to bring strong constraints on the high x partons and the poorly constrained photon content of the proton. Z cross sections are also measured at a center-of-mass energies of 8TeV and 13TeV, and cross-section ratios to the top-quark pair production have been derived. This ratio measurement leads to a cancellation of several systematic effects and allows therefore for a high precision comparison to the theory predictions.

  8. High precision measurements of carbon isotopic ratio of atmospheric methane using a continuous flow mass spectrometer

    Directory of Open Access Journals (Sweden)

    Shinji Morimoto

    2009-03-01

    Full Text Available A high-precision measurement system for the carbon isotope ratio of atmospheric CH4 (δ^(13CH_4 was developed using a pre-concentration device for CH4 and a gas chromatograph-combustion-isotope ratio mass spectrometer (GC-C-IRMS. The measurement system required 100 mlSTP of an atmospheric air sample, corresponding to approximately 0.18μlSTP of CH_4, to determine the δ^(13CH_4 value with a reproducibility of 0.07‰. Replicated analyses of a CH_4-in-air standard gas during the period from 2002 to 2008 indicated that the value of δ^(13CH_4 measured by this system was consistent within the measurement reproducibility. To evaluate the δ^(13CH_4 measurement system, thus developed, diurnal variations of the atmospheric CH_4 concentration and δ^(13CH_4 were observed in the northern part of the Tokyo metropolitan area. From the relationship between the CH_4 concentration and δ^(13CH_4, dominant sources of the observed CH4 fluctuations were identified.

  9. Measurement of the form factor ratios in semileptonic decays of charm mesons

    International Nuclear Information System (INIS)

    R. Zaliznyak

    1999-01-01

    I have measured the form factor ratios r 2 = A 2 (0)/A 1 (0) and r V = V (0)/A 1 (0) in the semileptonic charm meson decay D + → (anti K) *0 e + ν e from data collected by the Fermilab E791 collaboration. Form factors are introduced in the calculation of the hadronic current in semileptonic decays of strange, charm, or bottom mesons, such as D + → (anti K) *0 e + ν e . Semileptonic decays provide insight into quark coupling to the W boson since the leptonic and hadronic amplitudes in the Feynman diagram for the decay are completely separate. There are no strong interactions between the final state leptons and quarks. A number of theoretical models predict the values of the form factors for D + → (anti K) *0 e + ν e , though there is a large range of predictions. E791 is a hadroproduction experiment that recorded over 20 billion interactions with a 500 GeV π - beam incident on five thin targets during the 1991-92 Fermilab fixed-target run. Approximately 3000 D + → (anti K) *0 e + ν e decays are fully reconstructed. In order to extract the form factor ratios from the data, I implement a multidimensional unbinned maximum likelihood fit with a large sample of simulated (Monte Carlo) D + → (anti K) *0 e + ν e events. The large E791 data sample provides the most precise measurement of the form factor ratios to date. The measured values for the form factor ratios are r 2 = 0.71 ± 0.08 ± 0.09 and r V = 1.84 ± 0.11 ± 0.08. These results are in good agreement with some Lattice Gauge calculations. However the agreement with quark model predictions is not as good

  10. Residual Resistivity Ratio (RRR) Measurements of LHC Superconducting NbTi Cable Strands

    CERN Document Server

    Charifoulline, Z

    2006-01-01

    The Rutherford-type superconducting NbTi cables of the LHC accelerator are currently manufactured by six industrial companies. As a part of the acceptance tests, the Residual Resistivity Ratio (RRR) of superconducting strands is systematically measured on virgin strands to qualify the strands before cabling and on extracted strands to qualify the cables and to check the final heat treatment (controlled oxidation to control interstrand resistance). More than 12000 samples of virgin and extracted strands have been measured during last five years. Results show good correlation with the measurements done by the companies and reflect well the technological process of cable production (strand annealing, cabling, cable heat treatment). This paper presents a description of the RRR-test station and the measurement procedure, the summary of the results over all suppliers and finally the correlation between RRR-values of the cables and the magnets.

  11. Broadband measurements of high-frequency electric field levels and exposure ratios determination

    Directory of Open Access Journals (Sweden)

    Vulević Branislav

    2017-01-01

    Full Text Available The exposure of people to high-frequency electromagnetic fields (over 100 kHz that emanate from modern wireless information transmission systems is inevitable in modern times. Due to the rapid development of new technologies, measuring devices and their connection to measuring systems, the first fifteen years of the 21st century are characterized by the appearance of different approaches to measurements. This prompts the need for the assessment of the exposure of people to these fields. The main purpose of this paper is to show how to determine the exposure ratios based on the results of broadband measurements of the high-frequency electric field in the range of 3 MHz to 18 GHz in the environment.

  12. White-tailed deer age ratios as herd management and predator impact measures in Pennsylvania

    Science.gov (United States)

    Rosenberry, Christopher S.; Norton, Andrew S.; Diefenbach, Duane R.; Fleegle, Jeannine T.; Wallingford, Bret D.

    2011-01-01

    A review of the Pennsylvania Game Commission's (PGC) deer management program and public concern about predator impacts on deer (Odocoileus virginianus) populations compelled the PGC to investigate the role of age ratios in developing management recommendations. Age ratios, such as proportion of juveniles in the antlerless harvest, may provide an index to population productivity and predator impacts. We estimated proportion of juveniles in the antlerless harvest from hunter-killed deer, population trends using the Pennsylvania (USA) sex–age–kill model, and reproduction from road-killed females. Using these estimates and a simulation model, we concluded that no single age-ratio value would serve as a reliable measure of population status. Wildlife Management Unit-specific trends in proportion of juveniles in the antlerless harvest and population trends provided the most relevant management information. We also provide an example decision chart to guide management actions in response to declining age ratios in the harvest. Although predator management activities and juvenile survival studies are often desired by the public, our decision-chart example indicated a number of deer management options exist before investing resources in predator management activities and juvenile survival studies.

  13. Evaluation of the Urine Protein/Creatinine Ratio Measured with the Dipsticks Clinitek Atlas PRO 12.

    Science.gov (United States)

    Hermida, Fernando J; Soto, Sonia; Benitez, Alfonso J

    2016-01-01

    Screening for urine proteins is recommended for the detection of albuminuria in high risk groups. The aim of this study was to compare the Clinitek Atlas PRO12 reagent urine strip with quantitative methods for the determination of protein/creatinine ratio and to evaluate the usefulness of the semi-quantitative Clinitek Atlas PRO12 reagent urine strip as a tool in the early detection of albuminuria among the general population. Six hundred first morning urine specimens were collected from outpatients with various clinical conditions. The results showed that the test data for the urine dipstick Clinitek Atlas PRO12 show good agreement with the quantitative measurement of protein, creatinine and protein/creatinine ratio. In addition, this study shows that 97.2% of the samples which gave "normal" protein/creatinine ratios by the semi-quantitative method, showed albumin/creatinine ratio < 30 mg/g by the quantitative methods. Our results show that Clinitek Atlas PRO12 reagent strips can be used for the purposes of albuminuria screening in the general population.

  14. The use of Am-241 as Equivalence Thickness Measurement for Irradiation Room at National institute for Cancer and Malacca Hospital: A Review

    International Nuclear Information System (INIS)

    Mohd Khalid Matori; Azuhar Ripin; Husaini Salleh

    2013-01-01

    Lead equivalent thickness measurement of a shielding material in diagnostic radiology is very important to ensure that requirements for the purpose of radiation protection of patients, employees and the public are met. The Malaysian Ministry of Health (MOH) has established that the irradiation room must have sufficient shielding thickness, for example for general radiography it must be at least equal to 2.0 mm of Pb, for panoramic dental radiography at least equal to 1.5 mm of Pb and for mammography should be a minimum of 1.0 mm of Pb. This paper presents a technique using americium-241 source to test and verify the integrity of the shielding thickness in term of lead equivalent for irradiation room at National Institute for Cancer (IKN) and General Malacca Hospital. Results of measurement of 10 irradiation rooms conducted in 2012 were analyzed for this presentation. Technical comparison of the attenuation of gamma rays from Am-241 source through the walls of the irradiation room and pieces of lead were used to assess the lead equivalent thickness of the walls. Results showed that almost all the irradiation rooms tested meet the requirements of the Ministry of Health and is suitable for the installation of the intended diagnostic X-ray apparatus. Some specific positions such as door knobs and locks, electrical plug sockets were identified with potential to not met the required lead equivalent thickness hence may contribute to higher radiation exposure to workers and the public. (author)

  15. Gyromagnetic ratios of excited states in 198Pt; measurements and interacting boson approximation model calculations

    Science.gov (United States)

    Stuchbery, A. E.; Ryan, C. G.; Bolotin, H. H.; Morrison, I.; Sie, S. H.

    1981-07-01

    The enhanced transient hyperfine field manifest at the nuclei of swiftly recoiling ions traversing magnetized ferromagnetic materials was utilized to measure the gyromagnetic ratios of the 2 +1, 2 +2 and 4 +1 states in 198Pt by the thin-foil technique. The states of interest were populated by Coulomb excitation using a beam of 220 MeV 58Ni ions. The results obtained were: g(2 +1) = 0.324 ± 0.026; g(2 +2) = 0.34 ± 0.06; g(4 +1) = 0.34 ± 0.06. In addition, these measurements served to discriminate between the otherwise essentially equally probable values previously reported for the E2/M1 ratio of the 2 +2 → 2 +1 transition in 198Pt. We also performed interacting boson approximation (IBA) model-based calculations in the O(6) limit symmetry, with and without inclusion of a small degree of symmetry breaking, and employed the M1 operator in both first- and second-order to obtain M1 selection rules and to calculate gyromagnetic ratios of levels. When O(6) symmetry is broken, there is a predicted departure from constancy of the g-factors which provides a good test of the nuclear wave function. Evaluative comparisons are made between these experimental and predicted g-factors.

  16. High-precision branching ratio measurement for the superallowed β+ emitter 62Ga

    International Nuclear Information System (INIS)

    Finlay, P.E.J.

    2007-01-01

    A high-precision branching ratio measurement for the superallowed β + decay of 62 Ga was performed at the Isotope Separator and Accelerator radioactive ion beam facility. An array of 20 high-purity germanium detectors known as the 8π spectrometer was employed to detect the rays emitted following the Gamow-Teller and non-analog Fermi decays of 62 Ga, while the plastic scintillator array known as SCEPTAR was used to detect the emitted particles. A total of 32 γ rays were identified, establishing the superallowed branching ratio to be 99:859(8)%. Combined with the most recent half-life and Q-value measurements for 62 Ga, this branching ratio yields an ft-value of 3074.3 ± 1.1 s. Comparisons between the superallowed ft-value determined in this work and the world average Ft-bar are made, providing a benchmark for the refinement of theoretical models used to describe isospin-symmetry breaking in A ≥ 62 nuclei. (author)

  17. High-precision branching ratio measurement for the superallowed β+ emitter Ga62

    Science.gov (United States)

    Finlay, P.; Ball, G. C.; Leslie, J. R.; Svensson, C. E.; Towner, I. S.; Austin, R. A. E.; Bandyopadhyay, D.; Chaffey, A.; Chakrawarthy, R. S.; Garrett, P. E.; Grinyer, G. F.; Hackman, G.; Hyland, B.; Kanungo, R.; Leach, K. G.; Mattoon, C. M.; Morton, A. C.; Pearson, C. J.; Phillips, A. A.; Ressler, J. J.; Sarazin, F.; Savajols, H.; Schumaker, M. A.; Wong, J.

    2008-08-01

    A high-precision branching ratio measurement for the superallowed β+ decay of Ga62 was performed at the Isotope Separator and Accelerator (ISAC) radioactive ion beam facility. The 8π spectrometer, an array of 20 high-purity germanium detectors, was employed to detect the γ rays emitted following Gamow-Teller and nonanalog Fermi β+ decays of Ga62, and the SCEPTAR plastic scintillator array was used to detect the emitted β particles. Thirty γ rays were identified following Ga62 decay, establishing the superallowed branching ratio to be 99.858(8)%. Combined with the world-average half-life and a recent high-precision Q-value measurement for Ga62, this branching ratio yields an ft value of 3074.3±1.1 s, making Ga62 among the most precisely determined superallowed ft values. Comparison between the superallowed ft value determined in this work and the world-average corrected F tmacr value allows the large nuclear-structure-dependent correction for Ga62 decay to be experimentally determined from the CVC hypothesis to better than 7% of its own value, the most precise experimental determination for any superallowed emitter. These results provide a benchmark for the refinement of the theoretical description of isospin-symmetry breaking in A⩾62 superallowed decays.

  18. Measurement of the TeV atmospheric muon charge ratio with the complete OPERA data set

    Science.gov (United States)

    Agafonova, N.; Aleksandrov, A.; Anokhina, A.; Aoki, S.; Ariga, A.; Ariga, T.; Bender, D.; Bertolin, A.; Bozza, C.; Brugnera, R.; Buonaura, A.; Buontempo, S.; Büttner, B.; Chernyavsky, M.; Chukanov, A.; Consiglio, L.; D'Ambrosio, N.; De Lellis, G.; De Serio, M.; Del Amo Sanchez, P.; Di Crescenzo, A.; Di Ferdinando, D.; Di Marco, N.; Dmitrievski, S.; Dracos, M.; Duchesneau, D.; Dusini, S.; Dzhatdoev, T.; Ebert, J.; Ereditato, A.; Fini, R. A.; Fukuda, T.; Galati, G.; Garfagnini, A.; Giacomelli, G.; Göllnitz, C.; Goldberg, J.; Gornushkin, Y.; Grella, G.; Guler, M.; Gustavino, C.; Hagner, C.; Hara, T.; Hollnagel, A.; Hosseini, B.; Ishida, H.; Ishiguro, K.; Jakovcic, K.; Jollet, C.; Kamiscioglu, C.; Kamiscioglu, M.; Kawada, J.; Kim, J. H.; Kim, S. H.; Kitagawa, N.; Klicek, B.; Kodama, K.; Komatsu, M.; Kose, U.; Kreslo, I.; Lauria, A.; Lenkeit, J.; Ljubicic, A.; Longhin, A.; Loverre, P.; Malgin, A.; Malenica, M.; Mandrioli, G.; Matsuo, T.; Matveev, V.; Mauri, N.; Medinaceli, E.; Meregaglia, A.; Mikado, S.; Monacelli, P.; Montesi, M. C.; Morishima, K.; Muciaccia, M. T.; Naganawa, N.; Naka, T.; Nakamura, M.; Nakano, T.; Nakatsuka, Y.; Niwa, K.; Ogawa, S.; Okateva, N.; Olshevsky, A.; Omura, T.; Ozaki, K.; Paoloni, A.; Park, B. D.; Park, I. G.; Pasqualini, L.; Pastore, A.; Patrizii, L.; Pessard, H.; Pistillo, C.; Podgrudkov, D.; Polukhina, N.; Pozzato, M.; Pupilli, F.; Roda, M.; Rokujo, H.; Roganova, T.; Rosa, G.; Ryazhskaya, O.; Sato, O.; Schembri, A.; Shakiryanova, I.; Shchedrina, T.; Sheshukov, A.; Shibuya, H.; Shiraishi, T.; Shoziyoev, G.; Simone, S.; Sioli, M.; Sirignano, C.; Sirri, G.; Spinetti, M.; Stanco, L.; Starkov, N.; Stellacci, S. M.; Stipcevic, M.; Strolin, P.; Takahashi, S.; Tenti, M.; Terranova, F.; Tioukov, V.; Tufanli, S.; Vilain, P.; Vladimirov, M.; Votano, L.; Vuilleumier, J. L.; Wilquet, G.; Wonsak, B.; Yoon, C. S.; Zemskova, S.; Zghiche, A.

    2014-07-01

    The OPERA detector, designed to search for oscillations in the CNGS beam, is located in the underground Gran Sasso laboratory, a privileged location to study TeV-scale cosmic rays. For the analysis here presented, the detector was used to measure the atmospheric muon charge ratio in the TeV region. OPERA collected charge-separated cosmic ray data between 2008 and 2012. More than 3 million atmospheric muon events were detected and reconstructed, among which about 110000 multiple muon bundles. The charge ratio was measured separately for single and for multiple muon events. The analysis exploited the inversion of the magnet polarity which was performed on purpose during the 2012 Run. The combination of the two data sets with opposite magnet polarities allowed minimizing systematic uncertainties and reaching an accurate determination of the muon charge ratio. Data were fitted to obtain relevant parameters on the composition of primary cosmic rays and the associated kaon production in the forward fragmentation region. In the surface energy range 1-20 TeV investigated by OPERA, is well described by a parametric model including only pion and kaon contributions to the muon flux, showing no significant contribution of the prompt component. The energy independence supports the validity of Feynman scaling in the fragmentation region up to TeV/nucleon primary energy.

  19. Measurement of transparency ratios for protons from short-range correlated pairs

    Science.gov (United States)

    Hen, O.; Hakobyan, H.; Shneor, R.; Piasetzky, E.; Weinstein, L. B.; Brooks, W. K.; May-Tal Beck, S.; Gilad, S.; Korover, I.; Beck, A.; Adhikari, K. P.; Aghasyan, M.; Amaryan, M. J.; Anefalos Pereira, S.; Arrington, J. R.; Baghdasaryan, H.; Ball, J.; Battaglieri, M.; Batourine, V.; Bedlinskiy, I.; Biselli, A. S.; Bono, J.; Boiarinov, S.; Briscoe, W. J.; Burkert, V. D.; Carman, D. S.; Celentano, A.; Chandavar, S.; Cole, P. L.; Contalbrigo, M.; Crede, V.; D'Angelo, A.; Dashyan, N.; De Vita, R.; De Sanctis, E.; Deur, A.; Djalali, C.; Dodge, G. E.; Doughty, D.; Dupre, R.; Egiyan, H.; El Alaoui, A.; El Fassi, L.; Eugenio, P.; Fedotov, G.; Fegan, S.; Fleming, J. A.; Gabrielyan, M. Y.; Gevorgyan, N.; Gilfoyle, G. P.; Giovanetti, K. L.; Girod, F. X.; Goetz, J. T.; Gohn, W.; Golovatch, E.; Gothe, R. W.; Griffioen, K. A.; Guo, L.; Hafidi, K.; Harrison, N.; Heddle, D.; Hicks, K.; Holtrop, M.; Hyde, C. E.; Ilieva, Y.; Ireland, D. G.; Ishkhanov, B. S.; Isupov, E. L.; Jo, H. S.; Joo, K.; Keller, D.; Khandaker, M.; Khetarpal, P.; Kim, A.; Klein, F. J.; Koirala, S.; Kubarovsky, A.; Kubarovsky, V.; Kuhn, S. E.; Livingston, K.; Lu, H. Y.; MacGregor, I. J. D.; Martinez, D.; Mayer, M.; McKinnon, B.; Mineeva, T.; Mokeev, V.; Montgomery, R. A.; Moutarde, H.; Munevar, E.; Munoz Camacho, C.; Mustapha, B.; Nadel-Turonski, P.; Nasseripour, R.; Niccolai, S.; Niculescu, G.; Niculescu, I.; Osipenko, M.; Ostrovidov, A. I.; Pappalardo, L. L.; Paremuzyan, R.; Park, K.; Park, S.; Pasyuk, E.; Phelps, E.; Phillips, J. J.; Pisano, S.; Pivnyuk, N.; Pogorelko, O.; Pozdniakov, S.; Price, J. W.; Procureur, S.; Protopopescu, D.; Puckett, A. J. R.; Raue, B. A.; Rimal, D.; Ripani, M.; Ritchie, B. G.; Rosner, G.; Rossi, P.; Sabatié, F.; Saini, M. S.; Schott, D.; Schumacher, R. A.; Seraydaryan, H.; Sharabian, Y. G.; Smith, G. D.; Sober, D. I.; Sokhan, D.; Stepanyan, S. S.; Stepanyan, S.; Strauch, S.; Taiuti, M.; Tang, W.; Taylor, C. E.; Tian, Ye; Tkachenko, S.; Ungaro, M.; Vernarsky, B.; Vlassov, A.; Voskanyan, H.; Voutier, E.; Walford, N. K.; Watts, D. P.; Wood, M. H.; Zachariou, N.; Zana, L.; Zhang, J.; Zheng, X.; Zonta, I.

    2013-05-01

    Nuclear transparency, Tp (A), is a measure of the average probability for a struck proton to escape the nucleus without significant re-interaction. Previously, nuclear transparencies were extracted for quasi-elastic A (e ,e‧ p) knockout of protons with momentum below the Fermi momentum, where the spectral functions are well known. In this Letter we extract a novel observable, the transparency ratio, Tp (A) /Tp(12 C), for knockout of high-missing-momentum protons from the breakup of short-range correlated pairs (2N-SRC) in Al, Fe and Pb nuclei relative to C. The ratios were measured at momentum transfer Q2 ⩾ 1.5(GeV /c) 2 and xB ⩾ 1.2 where the reaction is expected to be dominated by electron scattering from 2N-SRC. The transparency ratios of the knocked-out protons coming from 2N-SRC breakup are 20-30% lower than those of previous results for low missing momentum. They agree with Glauber calculations and agree with renormalization of the previously published transparencies as proposed by recent theoretical investigations. The new transparencies scale as A - 1 / 3, which is consistent with dominance of scattering from nucleons at the nuclear surface.

  20. A new approach to estimate nuclide ratios from measurements with activities close to background

    International Nuclear Information System (INIS)

    Kirchner, G.; Steiner, M.; Zaehringer, M.

    2009-01-01

    Measurements of low-level radioactivity often give results of the order of the detection limit. For many applications, interest is not only in estimating activity concentrations of a single radioactive isotope, but focuses on multi-isotope analyses, which often enable inference on the source of the activity detected (e.g. from activity ratios). Obviously, such conclusions become questionable if the measurement merely gives a detection limit for a specific isotope. This is particularly relevant if the presence of an isotope, which shows a low signal only (e.g. due to a short half-life or a small transition probability), is crucial for gaining the information of interest. This paper discusses a new approach which has the potential to solve these problems. Using Bayesian statistics, a method is presented which allows statistical inference on nuclide ratios taking into account both prior knowledge and all information collected from the measurements. It is shown that our method allows quantitative conclusion to be drawn if counts of single isotopes are low or become even negative after background subtraction. Differences to the traditional statistical approach of specifying decision thresholds or detection limits are highlighted. Application of this new approach is illustrated by a number of examples of environmental low-level radioactivity measurements. The capabilities of our approach for spectrum interpretation and source identification are demonstrated with real spectra from air filters, sewage sludge and soil samples.

  1. Preliminary results of oxygen isotope ratio measurement with a particle-gamma coincidence method

    Energy Technology Data Exchange (ETDEWEB)

    Borysiuk, Maciek, E-mail: maciek.borysiuk@pixe.lth.se; Kristiansson, Per; Ros, Linus; Abdel, Nassem S.; Elfman, Mikael; Nilsson, Charlotta; Pallon, Jan

    2015-04-01

    The possibility to study variations in the oxygen isotopic ratio with photon tagged nuclear reaction analysis (pNRA) is evaluated in the current work. The experiment described in the article was performed at Lund Ion Beam Analysis Facility (LIBAF) with a 2 MeV deuteron beam. Isotopic fractionation of light elements such as carbon, oxygen and nitrogen is the basis of many analytical tools in hydrology, geology, paleobiology and paleogeology. IBA methods provide one possible tool for measurement of isotopic content. During this experimental run we focused on measurement of the oxygen isotopic ratio. The measurement of stable isotopes of oxygen has a number of applications; the particular one driving the current investigation belongs to the field of astrogeology and specifically evaluation of fossil extraterrestrial material. There are three stable isotopes of oxygen: {sup 16}O, {sup 17}O and {sup 18}O. We procured samples highly enriched with all three isotopes. Isotopes {sup 16}O and {sup 18}O were easily detected in the enriched samples, but no significant signal from {sup 17}O was detected in the same samples. The measured yield was too low to detect {sup 18}O in a sample with natural abundances of oxygen isotopes, at least in the current experimental setup, but the spectral line from the reaction with {sup 16}O was clearly visible.

  2. Measurement of the proton form factor ratio at low momentum transfer

    Energy Technology Data Exchange (ETDEWEB)

    Friedman, Moshe [Hebrew Univ. of Jerusalem (Israel)

    2016-08-01

    Experiment E08-007-II measured the proton elastic form factor ratio μGE=GM in the momentum transfer range of Q2 ~ 0.02 - 0.08 GeV2, the lowest ever measured by polarization transfer techniques. The experiment was performed at the Thomas Jefferson National Accelerator Facility in Newport News, Virginia, USA during 2012. A polarized electron beam with energies of 1.1, 1.7, and 2.2 GeV was elastically scattered off a polarized solid NH3 target. The asymmetries between the cross section of positive and negative helicity states of the beam were determined. These asymmetries can be used to determine the form factor ratio. In this thesis, we present the asymmetry analysis of the experiment, discuss the main challenges and show preliminary results for part of the data. Preliminary asymmetries indicate an increase in the form factor ratio above unity. However, a complete analysis is required before any conclusion can be made. Further analysis is ongoing, and final asymmetry results and form factor extraction is expected during 2017. We also present first results for 14N asymmetries for elastic and quasi-elastic scattering. The measured asymmetries are in agreement with the shell model approximation, within the low accuracy of the measurement. A change in the asymmetry sign between the elastic and the quasi-elastic processes is seen, and should motivate further theoretical studies. These experimental asymmetries will also be useful for systematic studies of other experiments using polarized NH3 targets.

  3. Determination of hydrogen/deuterium ratio with neutron measurements on MAST

    Energy Technology Data Exchange (ETDEWEB)

    Klimek, I., E-mail: iwona.klimek@physics.uu.se; Cecconello, M.; Ericsson, G. [Department of Physics and Astronomy, Uppsala University, Uppsala (Sweden); Sharapov, S. E.; Harrison, J. [CCFE, Culham Science Centre, Abingdon (United Kingdom)

    2014-11-15

    On MAST, compressional Alfvén eigenmodes can be destabilized by the presence of a sufficiently large population of energetic particles in the plasma. This dependence was studied in a series of very similar discharges in which increasing amounts of hydrogen were puffed into a deuterium plasma. A simple method to estimate the isotopic ratio n{sub H}/n{sub D} using neutron emission measurements is here described. The inferred isotopic ratio ranged from 0.0 to 0.6 and no experimental indication of changes in radial profile of n{sub H}/n{sub D} were observed. These findings are confirmed by TRANSP/NUBEAM simulations of the neutron emission.

  4. A measurement of the semileptonic branching ratio BR(b-baryon $\\rightarrow p l\\overline{\

    CERN Document Server

    Barate, R; Décamp, D; Ghez, P; Goy, C; Lees, J P; Lucotte, A; Minard, M N; Nief, J Y; Pietrzyk, B; Boix, G; Casado, M P; Chmeissani, M; Crespo, J M; Delfino, M C; Fernández, E; Fernández-Bosman, M; Garrido, L; Graugès-Pous, E; Juste, A; Martínez, M; Merino, G; Miquel, R; Mir, L M; Park, I C; Pascual, A; Perlas, J A; Riu, I; Sánchez, F; Colaleo, A; Creanza, D; De Palma, M; Gelao, G; Iaselli, Giuseppe; Maggi, G; Maggi, M; Marinelli, N; Nuzzo, S; Ranieri, A; Raso, G; Ruggieri, F; Selvaggi, G; Silvestris, L; Tempesta, P; Tricomi, A; Zito, G; Huang, X; Lin, J; Ouyang, Q; Wang, T; Xie, Y; Xu, R; Xue, S; Zhang, J; Zhang, L; Zhao, W; Abbaneo, D; Alemany, R; Becker, U; Bright-Thomas, P G; Casper, David William; Cattaneo, M; Cerutti, F; Ciulli, V; Dissertori, G; Drevermann, H; Forty, Roger W; Frank, M; Hagelberg, R; Hansen, J B; Harvey, J; Janot, P; Jost, B; Lehraus, Ivan; Mato, P; Minten, Adolf G; Moneta, L; Pacheco, A; Pusztaszeri, J F; Ranjard, F; Rolandi, Luigi; Rousseau, D; Schlatter, W D; Schmitt, M; Schneider, O; Tejessy, W; Teubert, F; Tomalin, I R; Wachsmuth, H W; Wagner, A; Ajaltouni, Ziad J; Badaud, F; Chazelle, G; Deschamps, O; Falvard, A; Ferdi, C; Gay, P; Guicheney, C; Henrard, P; Jousset, J; Michel, B; Monteil, S; Montret, J C; Pallin, D; Perret, P; Podlyski, F; Proriol, J; Rosnet, P; Fearnley, Tom; Hansen, J D; Hansen, J R; Hansen, P H; Nilsson, B S; Rensch, B; Wäänänen, A; Daskalakis, G; Kyriakis, A; Markou, C; Simopoulou, Errietta; Siotis, I; Vayaki, Anna; Blondel, A; Bonneaud, G R; Brient, J C; Bourdon, P; Rougé, A; Rumpf, M; Valassi, Andrea; Verderi, M; Videau, H L; Candlin, D J; Parsons, M I; Boccali, T; Focardi, E; Parrini, G; Zachariadou, K; Corden, M; Georgiopoulos, C H; Jaffe, D E; Antonelli, A; Bencivenni, G; Bologna, G; Bossi, F; Campana, P; Capon, G; Chiarella, V; Felici, G; Laurelli, P; Mannocchi, G; Murtas, F; Murtas, G P; Passalacqua, L; Pepé-Altarelli, M; Curtis, L; Dorris, S J; Halley, A W; Lynch, J G; Negus, P; O'Shea, V; Raine, C; Scarr, J M; Smith, K; Teixeira-Dias, P; Thompson, A S; Thomson, E; Thomson, F; Buchmüller, O L; Dhamotharan, S; Geweniger, C; Graefe, G; Hanke, P; Hansper, G; Hepp, V; Kluge, E E; Putzer, A; Sommer, J; Tittel, K; Werner, S; Wunsch, M; Beuselinck, R; Binnie, David M; Cameron, W; Dornan, Peter J; Girone, M; Goodsir, S M; Martin, E B; Moutoussi, A; Nash, J; Sedgbeer, J K; Spagnolo, P; Williams, M D; Ghete, V M; Girtler, P; Kneringer, E; Kuhn, D; Rudolph, G; Betteridge, A P; Bowdery, C K; Buck, P G; Colrain, P; Crawford, G; Finch, A J; Foster, F; Hughes, G; Jones, R W L; Williams, M I; Giehl, I; Greene, A M; Hoffmann, C; Jakobs, K; Kleinknecht, K; Quast, G; Renk, B; Rohne, E; Sander, H G; Van Gemmeren, P; Zeitnitz, C; Aubert, Jean-Jacques; Benchouk, C; Bonissent, A; Bujosa, G; Carr, J; Coyle, P; Diaconu, C A; Etienne, F; Leroy, O; Motsch, F; Payre, P; Talby, M; Sadouki, A; Thulasidas, M; Trabelsi, K; Aleppo, M; Antonelli, M; Ragusa, F; Berlich, R; Blum, Walter; Büscher, V; Dietl, H; Ganis, G; Gotzhein, C; Kroha, H; Lütjens, G; Lutz, Gerhard; Mannert, C; Männer, W; Moser, H G; Richter, R H; Rosado-Schlosser, A; Schael, S; Settles, Ronald; Seywerd, H C J; Stenzel, H; Wiedenmann, W; Wolf, G; Boucrot, J; Callot, O; Chen, S; Choi, Y; Cordier, A; Davier, M; Duflot, L; Grivaz, J F; Heusse, P; Höcker, A; Jacholkowska, A; Kim, D W; Le Diberder, F R; Lefrançois, J; Lutz, A M; Nikolic, I A; Schune, M H; Tournefier, E; Veillet, J J; Videau, I; Zerwas, D; Azzurri, P; Bagliesi, G; Batignani, G; Bettarini, S; Bozzi, C; Calderini, G; Carpinelli, M; Ciocci, M A; Dell'Orso, R; Fantechi, R; Ferrante, I; Foà, L; Forti, F; Giassi, A; Giorgi, M A; Gregorio, A; Ligabue, F; Lusiani, A; Marrocchesi, P S; Messineo, A; Palla, Fabrizio; Rizzo, G; Sanguinetti, G; Sciabà, A; Steinberger, Jack; Tenchini, Roberto; Tonelli, G; Vannini, C; Venturi, A; Verdini, P G; Blair, G A; Bryant, L M; Chambers, J T; Green, M G; Medcalf, T; Perrodo, P; Strong, J A; Von Wimmersperg-Töller, J H; Botterill, David R; Clifft, R W; Edgecock, T R; Haywood, S; Norton, P R; Thompson, J C; Wright, A E; Bloch-Devaux, B; Colas, P; Emery, S; Kozanecki, Witold; Lançon, E; Lemaire, M C; Locci, E; Pérez, P; Rander, J; Renardy, J F; Roussarie, A; Schuller, J P; Schwindling, J; Trabelsi, A; Vallage, B; Black, S N; Dann, J H; Johnson, R P; Kim, H Y; Konstantinidis, N P; Litke, A M; McNeil, M A; Taylor, G; Booth, C N; Brew, C A J; Cartwright, S L; Combley, F; Kelly, M S; Lehto, M H; Reeve, J; Thompson, L F; Affholderbach, K; Böhrer, A; Brandt, S; Cowan, G D; Grupen, Claus; Saraiva, P; Smolik, L; Stephan, F; Apollonio, M; Bosisio, L; Della Marina, R; Giannini, G; Gobbo, B; Musolino, G; Rothberg, J E; Wasserbaech, S R; Armstrong, S R; Charles, E; Elmer, P; Ferguson, D P S; Gao, Y; González, S; Greening, T C; Hayes, O J; Hu, H; Jin, S; McNamara, P A; Nachtman, J M; Nielsen, J; Orejudos, W; Pan, Y B; Saadi, Y; Scott, I J; Walsh, J; Wu Sau Lan; Wu, X; Yamartino, J M; Zobernig, G

    1998-01-01

    Inclusive pi^+/-, K^+/- (p,pbar) production is investigated using data recorded by the ALEPH detector between 1992 and 1994. The momentum spectra and multiplicities are measured separately in Z -->bbar, Z-->ccbar and Z-->uubar,ddbar,ssbar decays. The number of protons found in b-hadron decays is used to estimate the fraction of b-baryons in b-events to be (10.2 +/- 0.7 +/- 2.7)%. From an additional study of proton-lepton correlations in b events the branching ratio Br(b-baryon --> plnuX) = (4.63 +/- 0.72 +/- 0.98)% is obtained. The ratio Br(b-baryon --> plnuX)/ Br(b-baryon --> pX) is found to be 0.080 +/- 0.012 +/- 0.014.

  5. Measurement of the nuclear multiplicity ratio for Ks0 hadronization at CLAS

    Science.gov (United States)

    Daniel, A.; Hicks, K.; Brooks, W. K.; Hakobyan, H.; Adhikari, K. P.; Adikaram, D.; Aghasyan, M.; Amarian, M.; Anghinolfi, M.; Avakian, H.; Baghdasaryan, H.; Battaglieri, M.; Batourine, V.; Bedlinskiy, I.; Bennett, R. P.; Biselli, A. S.; Bookwalter, C.; Briscoe, W. J.; Burkert, V. D.; Carman, D. S.; Casey, L.; Celentano, A.; Chandavar, S.; Cole, P. L.; Contalbrigo, M.; Crede, V.; D'Angelo, A.; Dashyan, N.; De Vita, R.; De Sanctis, E.; Deur, A.; Dey, B.; Dickson, R.; Djalali, C.; Dodge, G. E.; Doughty, D.; Egiyan, H.; El Fassi, L.; Elouadrhiri, L.; Eugenio, P.; Fedotov, G.; Fegan, S.; Gabrielyan, M. Y.; Gevorgyan, N.; Gilfoyle, G. P.; Giovanetti, K. L.; Girod, F. X.; Goetz, J. T.; Gohn, W.; Golovatch, E.; Gothe, R. W.; Griffioen, K. A.; Guidal, M.; Guo, L.; Hanretty, C.; Heddle, D.; Holtrop, M.; Hyde, C. E.; Ilieva, Y.; Ireland, D. G.; Ishkhanov, B. S.; Isupov, E. L.; Jawalkar, S. S.; Jo, H. S.; Joo, K.; Kalantarians, N.; Keller, D.; Khandaker, M.; Khetarpal, P.; Kim, A.; Kim, W.; Klein, A.; Klein, F. J.; Kubarovsky, V.; Kuleshov, S. V.; Kuznetsov, V.; Lu, H. Y.; MacGregor, I. J. D.; Mao, Y.; Markov, N.; Mayer, M.; McAndrew, J.; McKinnon, B.; Meyer, C. A.; Mineeva, T.; Mirazita, M.; Mokeev, V.; Moutarde, H.; Munevar, E.; Nadel-Turonski, P.; Ni, A.; Niccolai, S.; Niculescu, G.; Niculescu, I.; Osipenko, M.; Ostrovidov, A. I.; Paolone, M.; Pappalardo, L.; Paremuzyan, R.; Park, K.; Park, S.; Pasyuk, E.; Anefalos Pereira, S.; Phelps, E.; Pisano, S.; Pogorelko, O.; Pozdniakov, S.; Price, J. W.; Procureur, S.; Protopopescu, D.; Raue, B. A.; Ricco, G.; Rimal, D.; Ripani, M.; Rosner, G.; Rossi, P.; Sabatié, F.; Saini, M. S.; Salgado, C.; Schott, D.; Schumacher, R. A.; Seraydaryan, H.; Sharabian, Y. G.; Smith, G. D.; Sober, D. I.; Sokhan, D.; Stepanyan, S. S.; Stepanyan, S.; Strauch, S.; Taiuti, M.; Tang, W.; Taylor, C. E.; Tkachenko, S.; Ungaro, M.; Vernarsky, B.; Vineyard, M. F.; Voskanyan, H.; Voutier, E.; Watts, D. P.; Weinstein, L. B.; Weygand, D. P.; Wood, M. H.; Zana, L.; Zachariou, N.; Zhao, B.; Zhao, Z. W.

    2011-11-01

    The influence of cold nuclear matter on lepto-production of hadrons in semi-inclusive deep inelastic scattering is measured using the CLAS detector in Hall B at Jefferson Lab and a 5.014 GeV electron beam. We report the Ks0 multiplicity ratios for targets of C, Fe, and Pb relative to deuterium as a function of the fractional virtual photon energy z transferred to the Ks0 and the transverse momentum squared pT2 of the Ks0. We find that the multiplicity ratios for Ks0 are reduced in the nuclear medium at high z and low pT2, with a trend for the Ks0 transverse momentum to be broadened in the nucleus for large pT2.

  6. Evaluation strategies for isotope ratio measurements of single particles by LA-MC-ICPMS.

    Science.gov (United States)

    Kappel, S; Boulyga, S F; Dorta, L; Günther, D; Hattendorf, B; Koffler, D; Laaha, G; Leisch, F; Prohaska, T

    2013-03-01

    Data evaluation is a crucial step when it comes to the determination of accurate and precise isotope ratios computed from transient signals measured by multi-collector-inductively coupled plasma mass spectrometry (MC-ICPMS) coupled to, for example, laser ablation (LA). In the present study, the applicability of different data evaluation strategies (i.e. 'point-by-point', 'integration' and 'linear regression slope' method) for the computation of (235)U/(238)U isotope ratios measured in single particles by LA-MC-ICPMS was investigated. The analyzed uranium oxide particles (i.e. 9073-01-B, CRM U010 and NUSIMEP-7 test samples), having sizes down to the sub-micrometre range, are certified with respect to their (235)U/(238)U isotopic signature, which enabled evaluation of the applied strategies with respect to precision and accuracy. The different strategies were also compared with respect to their expanded uncertainties. Even though the 'point-by-point' method proved to be superior, the other methods are advantageous, as they take weighted signal intensities into account. For the first time, the use of a 'finite mixture model' is presented for the determination of an unknown number of different U isotopic compositions of single particles present on the same planchet. The model uses an algorithm that determines the number of isotopic signatures by attributing individual data points to computed clusters. The (235)U/(238)U isotope ratios are then determined by means of the slopes of linear regressions estimated for each cluster. The model was successfully applied for the accurate determination of different (235)U/(238)U isotope ratios of particles deposited on the NUSIMEP-7 test samples.

  7. Sensitivity of film measured off-axis ratios to film calibration curve using radiochromic film

    International Nuclear Information System (INIS)

    Garcia-Hernandez, Diana; Larraga-Gutierrez, Jose M.

    2011-01-01

    Off-axis ratios of conical beams generated with a stereotactic radiosurgery-dedicated Linac were measured with EBT2 film and stereotactic diode. The sensitivity of both full width at half maximum (FWHM) and penumbras (80-20% and 90-10%, respectively), with respect to the characteristics of the film calibration curve fit, was investigated. In all cases, penumbras resulted to be more sensitive than FWHM. However, these differences were, in general, smaller than the ones found between EBT2 reference values and the stereotactic diode measurements. The larger variation in OAR parameters was found to depend on whether the fit intersected or not the origin. A 1D gamma-index analysis showed this difference can be important in all measured conical beams. (author)

  8. New recommendations for dose equivalent

    International Nuclear Information System (INIS)

    Bengtsson, G.

    1985-01-01

    In its report 39, the International Commission on Radiation Units and Measurements (ICRU), has defined four new quantities for the determination of dose equivalents from external sources: the ambient dose equivalent, the directional dose equivalent, the individual dose equivalent, penetrating and the individual dose equivalent, superficial. The rationale behind these concepts and their practical application are discussed. Reference is made to numerical values of these quantities which will be the subject of a coming publication from the International Commission on Radiological Protection, ICRP. (Author)

  9. Electron temperature measurement by a helium line intensity ratio method in helicon plasmas

    International Nuclear Information System (INIS)

    Boivin, R.F.; Kline, J.L.; Scime, E.E.

    2001-01-01

    Electron temperature measurements in helicon plasmas are difficult. The presence of intense rf fields in the plasma complicates the interpretation of Langmuir probe measurements. Furthermore, the non-negligible ion temperature in the plasma considerably shortens the lifetime of conventional Langmuir probes. A spectroscopic technique based on the relative intensities of neutral helium lines is used to measure the electron temperature in the HELIX (Hot hELicon eXperiment) plasma [P. A. Keiter et al., Phys. Plasmas 4, 2741 (1997)]. This nonintrusive diagnostic is based on the fact that electron impact excitation rate coefficients for helium singlet and triplet states differ as a function of the electron temperature. The different aspects related to the validity of this technique to measure the electron temperature in rf generated plasmas are discussed in this paper. At low plasma density (n e ≤10 11 cm -3 ), this diagnostic is believed to be very reliable since the population of the emitting level can be easily estimated with reasonable accuracy by assuming that all excitation originates from the ground state (steady-state corona model). At higher density, secondary processes (excitation transfer, excitation from metastable, cascading) become more important and a more complex collisional radiative model must be used to predict the electron temperature. In this work, different helium transitions are examined and a suitable transition pair is identified. For an electron temperature of 10 eV, the line ratio is measured as a function of plasma density and compared to values predicted by models. The measured line ratio function is in good agreement with theory and the data suggest that the excitation transfer is the dominant secondary process in high-density plasmas

  10. Estimation of uncertainty bounds for individual particle image velocimetry measurements from cross-correlation peak ratio

    International Nuclear Information System (INIS)

    Charonko, John J; Vlachos, Pavlos P

    2013-01-01

    Numerous studies have established firmly that particle image velocimetry (PIV) is a robust method for non-invasive, quantitative measurements of fluid velocity, and that when carefully conducted, typical measurements can accurately detect displacements in digital images with a resolution well below a single pixel (in some cases well below a hundredth of a pixel). However, to date, these estimates have only been able to provide guidance on the expected error for an average measurement under specific image quality and flow conditions. This paper demonstrates a new method for estimating the uncertainty bounds to within a given confidence interval for a specific, individual measurement. Here, cross-correlation peak ratio, the ratio of primary to secondary peak height, is shown to correlate strongly with the range of observed error values for a given measurement, regardless of flow condition or image quality. This relationship is significantly stronger for phase-only generalized cross-correlation PIV processing, while the standard correlation approach showed weaker performance. Using an analytical model of the relationship derived from synthetic data sets, the uncertainty bounds at a 95% confidence interval are then computed for several artificial and experimental flow fields, and the resulting errors are shown to match closely to the predicted uncertainties. While this method stops short of being able to predict the true error for a given measurement, knowledge of the uncertainty level for a PIV experiment should provide great benefits when applying the results of PIV analysis to engineering design studies and computational fluid dynamics validation efforts. Moreover, this approach is exceptionally simple to implement and requires negligible additional computational cost. (paper)

  11. Measurement of the tau lifetime and leptonic branching ratios in L3

    International Nuclear Information System (INIS)

    Garcia-Abia, P.

    2001-01-01

    Using data collected with the L3 detector near the Z resonance corresponding to an integrated luminosity of 150 pb -1 the lifetime of the tau lepton is measured to be τ τ = 293.2 ± 2.0(stat.) ± 1.5(sys.) fs, and the branching ratios of the tau lepton into electron and muon are measured to be B(τ → eν-bar e ν τ ) = (17.806 ± 0.104 (stat.)±0.076(sys.))% and B(τ → μν-bar μ ν τ ) = (17.342 ± 0.110 (stat.)±0.067(sys.))%, respectively. From these results the ratio of the charged current coupling constants g μ /g e , g τ /g e and g τ /g μ are determined and support the lepton universality hypothesis. The Fermi-constant and the coupling constant of the strong interaction at the tau mass are obtained from these measurements

  12. Signal-to-noise ratio measurement in parallel MRI with subtraction mapping and consecutive methods

    International Nuclear Information System (INIS)

    Imai, Hiroshi; Miyati, Tosiaki; Ogura, Akio; Doi, Tsukasa; Tsuchihashi, Toshio; Machida, Yoshio; Kobayashi, Masato; Shimizu, Kouzou; Kitou, Yoshihiro

    2008-01-01

    When measuring the signal-to-noise ratio (SNR) of an image the used parallel magnetic resonance imaging, it was confirmed that there was a problem in the application of past SNR measurement. With the method of measuring the noise from the background signal, SNR with parallel imaging was higher than that without parallel imaging. In the subtraction method (NEMA standard), which sets a wide region of interest, the white noise was not evaluated correctly although SNR was close to the theoretical value. We proposed two techniques because SNR in parallel imaging was not uniform according to inhomogeneity of the coil sensitivity distribution and geometry factor. Using the first method (subtraction mapping), two images were scanned with identical parameters. The SNR in each pixel divided the running mean (7 by 7 pixels in neighborhood) by standard deviation/√2 in the same region of interest. Using the second (consecutive) method, more than fifty consecutive scans of the uniform phantom were obtained with identical scan parameters. Then the SNR was calculated from the ratio of mean signal intensity to the standard deviation in each pixel on a series of images. Moreover, geometry factors were calculated from SNRs with and without parallel imaging. The SNR and geometry factor using parallel imaging in the subtraction mapping method agreed with those of the consecutive method. Both methods make it possible to obtain a more detailed determination of SNR in parallel imaging and to calculate the geometry factor. (author)

  13. Odds Ratio Product of Sleep EEG as a Continuous Measure of Sleep State

    Science.gov (United States)

    Younes, Magdy; Ostrowski, Michele; Soiferman, Marc; Younes, Henry; Younes, Mark; Raneri, Jill; Hanly, Patrick

    2015-01-01

    Study Objectives: To develop and validate an algorithm that provides a continuous estimate of sleep depth from the electroencephalogram (EEG). Design: Retrospective analysis of polysomnograms. Setting: Research laboratory. Participants: 114 patients who underwent clinical polysomnography in sleep centers at the University of Manitoba (n = 58) and the University of Calgary (n = 56). Interventions: None. Measurements and Results: Power spectrum of EEG was determined in 3-second epochs and divided into delta, theta, alpha-sigma, and beta frequency bands. The range of powers in each band was divided into 10 aliquots. EEG patterns were assigned a 4-digit number that reflects the relative power in the 4 frequency ranges (10,000 possible patterns). Probability of each pattern occurring in 30-s epochs staged awake was determined, resulting in a continuous probability value from 0% to 100%. This was divided by 40 (% of epochs staged awake) producing the odds ratio product (ORP), with a range of 0–2.5. In validation testing, average ORP decreased progressively as EEG progressed from wakefulness (2.19 ± 0.29) to stage N3 (0.13 ± 0.05). ORP sleep and ORP > 2.0 predicted wakefulness in > 95% of 30-s epochs. Epochs with intermediate ORP occurred in unstable sleep with a high arousal index (> 70/h) and were subject to much interrater scoring variability. There was an excellent correlation (r2 = 0.98) between ORP in current 30-s epochs and the likelihood of arousal or awakening occurring in the next 30-s epoch. Conclusions: Our results support the use of the odds ratio product (ORP) as a continuous measure of sleep depth. Citation: Younes M, Ostrowski M, Soiferman M, Younes H, Younes M, Raneri J, Hanly P. Odds ratio product of sleep EEG as a continuous measure of sleep state. SLEEP 2015;38(4):641–654. PMID:25348125

  14. Online stable carbon isotope ratio measurement in formic acid, acetic acid, methanol and ethanol in water by high performance liquid chromatography-isotope ratio mass spectrometry

    International Nuclear Information System (INIS)

    Tagami, Keiko; Uchida, Shigeo

    2008-01-01

    A suitable analysis condition was determined for high performance liquid chromatography-isotope ratio mass spectrometry (HPLC-IRMS) while making sequential measurements of stable carbon isotope ratios of δ 13 C in formic acid, acetic acid, methanol and ethanol dissolved in water. For this online column separation method, organic reagents are not applicable due to carbon contamination; thus, water and KH 2 PO 4 at low concentrations were tested as mobile phase in combination with a HyPURITY AQUASTAR TM column. Formic acid, acetic acid, methanol and ethanol were separated when 2 mM KH 2 PO 4 aqueous solution was used. Under the determined analysis condition for HPLC-IRMS, carbon concentrations could be measured quantitatively as well as carbon isotope ratio when carbon concentration was higher than 0.4 mM L for each chemical

  15. Recent Developments in Trace, Ultratrace and Isotope Ratio Measurements in Inductively Coupled Plasma Mass Spectrometry

    International Nuclear Information System (INIS)

    Zahran, N. F.

    2004-01-01

    Inductively coupled plasma mass spectrometry (ICP-MS) and Laser Ablation (LA-ICP-MS) are recent techniques for trace, ultratrace and isotope ratio measurements. Main features of these techniques and their figure of merit and capabilities are discussed. An overview of ICP-MS instrument is presented in addition to its precision, accuracy and detection limits. Uses of ICP-MS in environmental monitoring in some cases for detection of some radio nuclides are presented. Two geological applications namely, zircon grains analysis and age dating of Rb-Sr method are presented. Zn elemental and isotopic analyses in blood and serum as a biological application is shown. (Author)

  16. Measurement of the branching ratio and polarization for J/psi→γf(1270)

    International Nuclear Information System (INIS)

    Edwards, C.; Partridge, R.; Peck, C.; Porter, F.C.; Antreasyan, D.; Gu, Y.F.; Kollmann, W.; Richardson, M.; Strauch, K.; Wacker, K.; Weinstein, A.; Aschman, D.; Burnett, T.; Cavalli-Sforza, M.; Coyne, D.; Newman, C.; Sadrozinski, H.F.W.; Gelphman, D.; Hofstadter, R.; Horisberger, R.; Kirkbride, I.; Kolanoski, H.; Koenigsmann, K.; Lee, R.; Liberman, A.; O'Reilly, J.; Osterheld, A.; Pollock, B.; Tompkins, J.; Bloom, E.; Bulos, F.; Chestnut, R.; Gaiser, J.; Godfrey, J.; Kiesling, C.; Lockman, W.; Oreglia, M.; Scharre, D.L

    1982-01-01

    The decay J/psi→γf(1270), f(1270)→π 0 π 0 has been studied. The γf decay branching ratio is measured to be (1.48 +- 0.25 +- 0.30) x 10 -3 . A fit to the f production and decay angular distributions yields the values A 1 /A 0 = 0.88 +- 0.13 and A 2 /A 0 = 0.04 +- 0.19, where A/sub lambda/ are the f helicity amplitudes. These results disagree with the values predicted from a QCD two-gluon-exchange model

  17. Measurements of neutron fluxes and cadmium ratio at equilibrium core in JRR-3M

    International Nuclear Information System (INIS)

    Ohtomo, Akitoshi; Sasajima, Fumio; Ishida, Takuya; Shigemoto, Masamitsu; Takahashi, Hidetake; Maejima, Takeshi; Sekine, Katsunori.

    1993-08-01

    Construction and characteristics tests of JRR-3M (Modified JRR-3) had been completed on October 1990, and the reactor reached to equilibrium core in July 1991. Measurements of neutron flux and cadmium ratio in Hydraulic irradiation facility (HR) and Pneumatic irradiation facility (PN) at 20 MW reactor power were carried out for the equilibrium core from May to August 1991 and for the latest core in April 1993. The results at the equilibrium core and the latest core are described in this paper. (author)

  18. WormGender - Open-Source Software for Automatic Caenorhabditis elegans Sex Ratio Measurement.

    Directory of Open Access Journals (Sweden)

    Marta K Labocha

    Full Text Available Fast and quantitative analysis of animal phenotypes is one of the major challenges of current biology. Here we report the WormGender open-source software, which is designed for accurate quantification of sex ratio in Caenorhabditis elegans. The software functions include, i automatic recognition and counting of adult hermaphrodites and males, ii a manual inspection feature that enables manual correction of errors, and iii flexibility to use new training images to optimize the software for different imaging conditions. We evaluated the performance of our software by comparing manual and automated assessment of sex ratio. Our data showed that the WormGender software provided overall accurate sex ratio measurements. We further demonstrated the usage of WormGender by quantifying the high incidence of male (him phenotype in 27 mutant strains. Mutants of nine genes (brc-1, C30G12.6, cep-1, coh-3, him-3, him-5, him-8, skr-1, unc-86 showed significant him phenotype. The WormGender is written in Java and can be installed and run on both Windows and Mac platforms. The source code is freely available together with a user manual and sample data at http://www.QuantWorm.org/. The source code and sample data are also available at http://dx.doi.org/10.6084/m9.figshare.1541248.

  19. Development of snow water equivalent survey methods using airborne gamma measurements. Research progress, January 1975--September 1975 and suggested directions for future work

    International Nuclear Information System (INIS)

    Fritzsche, A.; Jupiter, C.

    1975-01-01

    This is a summary of the progress made during the period March 1975 through September 1975 on EG and G's support of the National Oceanic and Atmospheric Administration for development of airborne techniques for measurement of the water equivalent of snow and soil moisture. The work included a series of snow and soil moisture surveys and development of a new detector and data acquisition system. The status of this work is summarized here together with a review of plans for the immediate future

  20. Measuring instruments of the Physikalisch-Technische Bundesanstalt for realization of the units of the dosimetric quantities standard ion dose, photon-equivalent dose and air-kerma

    International Nuclear Information System (INIS)

    Engelke, B.A.; Oetzmann, W.; Struppek, G.

    1988-08-01

    The realization of the units of the dosimetric quantities exposure, air-kerma and photon-equivalent dose is an important task of the Physikalisch-Technische Bundesanstalt. The report describes the measuring instruments and other technical equipment as well as the determination of the numerous corrections needed. All data and correction factors required for the realization of the units mentioned above are given in many diagrams and tables. (orig.) [de

  1. Cultural and semantic equivalence of the activity measure post-acute care (AM-PAC) after its translation into Mandarin Chinese.

    Science.gov (United States)

    Chang, Feng-Hang; Ni, Pengsheng; Chiou, Hung-Yi; Hou, Wen-Hsuan; Jette, Alan M

    2018-03-21

    The purpose of this study was to investigate the cultural and semantic equivalence of the Activity Measure Post-Acute Care (AM-PAC) outpatient short forms after they were translated from American English to Mandarin Chinese. This study was conducted with a composite sample of a group of 483 American adults (mean age 63.1 years, 42.4% males) and 553 Taiwanese adults (mean age 60.6 years, 47.2% males) who were undergoing home care or outpatient rehabilitation services. A confirmatory factor analysis tested the cultural equivalence of the AM-PAC dimensions between the US and Taiwanese samples. Semantic equivalence was tested through an item response theory-based differential item functioning (DFI) analysis. Results of the confirmatory factor analysis demonstrated good model-data fit of the AM-PAC in both the US and Taiwanese samples. Significant DFI was found for six Basic Mobility items, two Daily Activity items, and four Applied Cognition items. A DFI-adjusted conversion table was generated to transform the raw scores of the measure for comparisons between the two countries. This study provides evidence to support the conceptual equivalence of the AM-PAC when used in rehabilitation patients between American and Taiwanese cultural contexts. Some DFI items between the two groups were found, suggesting that some differences in semantic understanding of these items between cultures require cross-cultural adjustments. Implications for Rehabilitation Cultural equivalence needs to be tested before applying a clinical measure to another context. The findings of this study supported the three activity domains that the Activity Measure Post-Acute Care measures: Basic Mobility, Daily Activity, and Applied Cognition, which are all important rehabilitation outcomes that need to be assessed and monitored across rehabilitation settings. Differential item functioning was observed between the English and Chinese versions of the Activity Measure Post-Acute Care, indicating that

  2. The stability of H/V spectral ratios from noise measurements in Armutlu Peninsula (Turkey)

    Energy Technology Data Exchange (ETDEWEB)

    Livaoğlu, Hamdullah, E-mail: hamdullah.livaoglu@kocaeli.edu.tr; Irmak, T. Serkan; Caka, Deniz; Yavuz, Evrim; Tunç, B.; Baris, S. [Faculty of Engineering, Department of Geophysics, Kocaeli University, 41380, Kocaeli (Turkey); Lühr, B. G.; Woith, H. [GFZ, German Research Centre for Geoscience, Postsdam (Germany)

    2016-04-18

    The horizontal to vertical spectral ratio (H/V) method has been successfully using in order to estimate the fundamental resonance frequency of the sedimentary cover, its thickness and amplification factor since at least 3 decades. There are numerous studies have been carried out on the stability of the H/V spectral ratios. Almost all studies showed that fundamental frequency is stable even measurements are repeated at different times. From this point of view, the results will show us an approach whether the stations are suitable for accurate estimate of earthquake studies and engineering purposes or not. Also we want to see if any effects of the amplification factor changing on the seismograms for Armutlu Seismic Network (ARNET) even though seismic stations are established far away from cultural noise and located on hard rock sites. It has been selected one hour recorded data of all stations during the most stationary times. The amplification and resonant frequency variations of H/V ratio were calculated to investigate temporal stability in time. There is a total harmony in fundamental frequencies values and H/V spectral ratio values in time-lagged periods. Some stations shows secondary minor peaks in high frequency band due to a shallow formation effect or cultural noises around. In the east side of the area ILYS station shows amplitude peak in lower fundamental frequency band from expected. This could compose a high amplification in lower frequencies and so that yield less reliable results in local earthquakes studies. By the experimental results from ambient noise analysis, it could be worked up for relocation of one station.

  3. Measurement of the form factor ratios in semileptonic decays of charm mesons

    Energy Technology Data Exchange (ETDEWEB)

    Zaliznyak, Renata [Stanford Univ., CA (United States)

    1998-05-01

    I have measured the form factor ratios r2 = A2 (0)/A1 (0) and rV = V (0)/A1 (0) in the semileptonic charm meson decay D+ → $\\bar{K}$*0 e+ve from data collected by the Fermilab E791 collaboration. Form factors are introduced in the calculation of the hadronic current in semileptonic decays of strange, charm, or bottom mesons, such as D+ → $\\bar{K}$*0 e+ ve . Semileptonic decays provide insight into quark coupling to the W boson since the leptonic and hadronic amplitudes in the Feynman diagram for the decay are completely separate. There are no strong interactions between the final state leptons and quarks. A number of theoretical models predict the values of the form factors for D+ → $\\bar{K}$*0 e+ ve , though there is a large range of predictions. E791 is a hadroproduction experiment that recorded over 20 billion interactions with a 500 GeV π- beam incident on five thin targets during the 1991-92 Fermilab fixed-target run. Approximately 3000 D+ → $\\bar{K}$*0 e+ ve decays are fully reconstructed. In order to extract the form factor ratios from the data, I implement a multidimensional unbinned maximum likelihood fit with a large sample of simulated (Monte Carlo) D+ → $\\bar{K}$*0 e+ve events. The large E791 data sample provides the most precise measurement of the form factor ratios to date. The measured values for the form factor ratios are r2 = 0.71 ± 0.08 ± 0.09 and rV = 1.84 ± 0.11 ±} 0.08. These results are in good agreement with some Lattice Gauge calculations. However the agreement with quark model predictions is not as good.

  4. Correlation techniques for the improvement of signal-to-noise ratio in measurements with stochastic processes

    CERN Document Server

    Reddy, V R; Reddy, T G; Reddy, P Y; Reddy, K R

    2003-01-01

    An AC modulation technique is described to convert stochastic signal variations into an amplitude variation and its retrieval through Fourier analysis. It is shown that this AC detection of signals of stochastic processes when processed through auto- and cross-correlation techniques improve the signal-to-noise ratio; the correlation techniques serve a similar purpose of frequency and phase filtering as that of phase-sensitive detection. A few model calculations applied to nuclear spectroscopy measurements such as Angular Correlations, Mossbauer spectroscopy and Pulse Height Analysis reveal considerable improvement in the sensitivity of signal detection. Experimental implementation of the technique is presented in terms of amplitude variations of harmonics representing the derivatives of normal spectra. Improved detection sensitivity to spectral variations is shown to be significant. These correlation techniques are general and can be made applicable to all the fields of particle counting where measurements ar...

  5. a High-Precision Branching-Ratio Measurement for the Superallowed β+ Emitter 74Rb

    Science.gov (United States)

    Dunlop, R.; Chagnon-Lessard, S.; Finlay, P.; Garrett, P. E.; Hadinia, B.; Leach, K. G.; Svensson, C. E.; Wong, J.; Ball, G.; Garnsworthy, A. B.; Glister, J.; Hackman, G.; Tardiff, E. R.; Triambak, S.; Williams, S. J.; Leslie, J. R.; Andreoiu, C.; Chester, A.; Cross, D.; Starosta, K.; Yates, S. W.; Zganjar, E. F.

    2013-03-01

    Precision measurements of superallowed Fermi beta decay allow for tests of the Cabibbo-Kobayashi-Maskawa matrix (CKM) unitarity, the conserved vector current hypothesis, and the magnitude of isospin-symmetry-breaking effects in nuclei. A high-precision measurement of the branching ratio for the β+ decay of 74Rb has been performed at the Isotope Separator and ACcelerator (ISAC) facility at TRIUMF. The 8π spectrometer, an array of 20 close-packed HPGe detectors, was used to detect gamma rays emitted following the decay of 74Rb. PACES, an array of 5 Si(Li) detectors, was used to detect emitted conversion electrons, while SCEPTAR, an array of plastic scintillators, was used to detect emitted beta particles. A total of 51γ rays have been identified following the decay of 21 excited states in the daughter nucleus 74Kr.

  6. Technical note: Using distributed temperature sensing for Bowen ratio evaporation measurements

    Science.gov (United States)

    Schilperoort, Bart; Coenders-Gerrits, Miriam; Luxemburg, Willem; Jiménez Rodríguez, César; Cisneros Vaca, César; Savenije, Hubert

    2018-01-01

    Rapid improvements in the precision and spatial resolution of distributed temperature sensing (DTS) technology now allow its use in hydrological and atmospheric sciences. Introduced by ) is the use of DTS for measuring the Bowen ratio (BR-DTS), to estimate the sensible and latent heat flux. The Bowen ratio is derived from DTS-measured vertical profiles of the air temperature and wet-bulb temperature. However, in previous research the measured temperatures were not validated, and the cables were not shielded from solar radiation. Additionally, the BR-DTS method has not been tested above a forest before, where temperature gradients are small and energy storage in the air column becomes important. In this paper the accuracy of the wet-bulb and air temperature measurements of the DTS are verified, and the resulting Bowen ratio and heat fluxes are compared to eddy covariance data. The performance of BR-DTS was tested on a 46 m high tower in a mixed forest in the centre of the Netherlands in August 2016. The average tree height is 26 to 30 m, and the temperatures are measured below, in, and above the canopy. Using the vertical temperature profiles the storage of latent and sensible heat in the air column was calculated. We found a significant effect of solar radiation on the temperature measurements, leading to a deviation of up to 3 K. By installing screens, the error caused by sunlight is reduced to under 1 K. Wind speed seems to have a minimal effect on the measured wet-bulb temperature, both below and above the canopy. After a simple quality control, the Bowen ratio measured by DTS correlates well with eddy covariance (EC) estimates (r2 = 0.59). The average energy balance closure between BR-DTS and EC is good, with a mean underestimation of 3.4 W m-2 by the BR-DTS method. However, during daytime the BR-DTS method overestimates the available energy, and during night-time the BR-DTS method estimates the available energy to be more negative. This difference could be

  7. On the Use of Line Depth Ratios to Measure Starspot Properties on Magnetically Active Stars

    Science.gov (United States)

    O'Neal, Douglas

    2006-07-01

    Photometric and spectroscopic techniques have proven to be effective ways to measure the properties of dark, cool starspots on magnetically active stars. Recently, a technique was introduced using atomic line depth ratios (LDRs) to measure starspot properties. Carefully reproducing this technique using a new set of spectroscopic observations of active stars, we find that the LDR technique encounters difficulties, specifically by overestimating spot temperatures (because the atomic lines blend with titanium oxide absorption in cooler spots) and by not tightly constraining the filling factor of spots. While the use of LDRs for active star studies has great promise, we believe that these concerns need to be addressed before the technique is more widely applied. This paper includes data taken at McDonald Observatory of the University of Texas at Austin.

  8. Electron density profile measurements from hydrogen line intensity ratio method in Versatile Experimental Spherical Torus

    Energy Technology Data Exchange (ETDEWEB)

    Kim, YooSung; Shi, Yue-Jiang, E-mail: yjshi@snu.ac.kr; Yang, Jeong-hun; Kim, SeongCheol; Kim, Young-Gi; Dang, Jeong-Jeung; Yang, Seongmoo; Jo, Jungmin; Chung, Kyoung-Jae [Department of Nuclear Engineering, Seoul National University, Seoul 151-744 (Korea, Republic of); Oh, Soo-Ghee [Division of Energy Systems Research, Ajou University, Suwon 442-749 (Korea, Republic of); Hwang, Y. S. [Department of Nuclear Engineering, Seoul National University, Seoul 151-744 (Korea, Republic of); Center for Advanced Research in Fusion Reactor Engineering, Seoul National University, Seoul 151-744 (Korea, Republic of)

    2016-11-15

    Electron density profiles of versatile experiment spherical torus plasmas are measured by using a hydrogen line intensity ratio method. A fast-frame visible camera with appropriate bandpass filters is used to detect images of Balmer line intensities. The unique optical system makes it possible to take images of H{sub α} and H{sub β} radiation simultaneously, with only one camera. The frame rate is 1000 fps and the spatial resolution of the system is about 0.5 cm. One-dimensional local emissivity profiles have been obtained from the toroidal line of sight with viewing dumps. An initial result for the electron density profile is presented and is in reasonable agreement with values measured by a triple Langmuir probe.

  9. Measurement of the positron to electron ratio in the cosmic rays above 5 GeV

    International Nuclear Information System (INIS)

    Golden, R.L.; Stochaj, S.J.; Stephens, S.A.; Aversa, F.; Barbiellini, G.; Boezio, M.; Bravar, U.; Colavita, A.; Fratnik, F.

    1995-12-01

    As part of a series of experiments to search for antimatter in cosmic rays, the NMSU balloon-borne magnet spectrometer was configured for a flight to study positrons. Two completely new instruments, a transition radiation detector and a silicon-tungsten imaging calorimeter, were added to the magnet spectrometer. These two detectors provided a proton rejection factor better than (3) (10) 4 . This instrument was flown from Fort Sumner, NM at an average depth of 4.5 g/cm 2 of residual atmosphere for a period of 25 hours. The paper reports the measured fraction of positrons e + /e + +e - from about 5 to 60 GeV at the top of the atmosphere. The measurements do not show any compelling evidence for an increase in this ratio with energy and the results are consistent with a constant fraction of 0.78±0.016 over the entire region

  10. The differential Howland current source with high signal to noise ratio for bioimpedance measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jinzhen; Li, Gang; Lin, Ling, E-mail: linling@tju.edu.cn [State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin, People' s Republic of China, and Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin University, Tianjin (China); Qiao, Xiaoyan [College of Physics and Electronic Engineering, Shanxi University, Shanxi (China); Wang, Mengjun [School of Information Engineering, Hebei University of Technology, Tianjin (China); Zhang, Weibo [Institute of Acupuncture and Moxibustion China Academy of Chinese Medical Sciences, Beijing (China)

    2014-05-15

    The stability and signal to noise ratio (SNR) of the current source circuit are the important factors contributing to enhance the accuracy and sensitivity in bioimpedance measurement system. In this paper we propose a new differential Howland topology current source and evaluate its output characters by simulation and actual measurement. The results include (1) the output current and impedance in high frequencies are stabilized after compensation methods. And the stability of output current in the differential current source circuit (DCSC) is 0.2%. (2) The output impedance of two current circuits below the frequency of 200 KHz is above 1 MΩ, and below 1 MHz the output impedance can arrive to 200 KΩ. Then in total the output impedance of the DCSC is higher than that of the Howland current source circuit (HCSC). (3) The SNR of the DCSC are 85.64 dB and 65 dB in the simulation and actual measurement with 10 KHz, which illustrates that the DCSC effectively eliminates the common mode interference. (4) The maximum load in the DCSC is twice as much as that of the HCSC. Lastly a two-dimensional phantom electrical impedance tomography is well reconstructed with the proposed HCSC. Therefore, the measured performance shows that the DCSC can significantly improve the output impedance, the stability, the maximum load, and the SNR of the measurement system.

  11. Magnetisation transfer ratio measurement in the cervical spinal cord: a preliminary study in multiple sclerosis

    Energy Technology Data Exchange (ETDEWEB)

    Silver, N.C. [NMR Research Unit and Department of Clinical Neurology, Institute of Neurology, Queen Square, London WC1N 3BG (United Kingdom); Barker, G.J. [NMR Research Unit and Department of Clinical Neurology, Institute of Neurology, Queen Square, London WC1N 3BG (United Kingdom); Losseff, N.A. [NMR Research Unit and Department of Clinical Neurology, Institute of Neurology, Queen Square, London WC1N 3BG (United Kingdom); Gawne-Cain, M.L. [NMR Research Unit and Department of Clinical Neurology, Institute of Neurology, Queen Square, London WC1N 3BG (United Kingdom); MacManus, D.G. [NMR Research Unit and Department of Clinical Neurology, Institute of Neurology, Queen Square, London WC1N 3BG (United Kingdom); Thompson, A.J. [NMR Research Unit and Department of Clinical Neurology, Institute of Neurology, Queen Square, London WC1N 3BG (United Kingdom); Miller, D.H. [NMR Research Unit and Department of Clinical Neurology, Institute of Neurology, Queen Square, London WC1N 3BG (United Kingdom)

    1997-06-01

    MRI readily detects the lesions of multiple sclerosis (MS) in the brain and spinal cord. Conventional MRI sequences do not, however, permit distinction between the various pathological characteristics (oedema, demyelination, axonal loss and gliosis) of lesions in MS. Magnetisation transfer (MT) imaging may be more specific in distinguishing the pathologies responsible for disability in MS, namely demyelination and axonal loss, and therefore may have a potential role in monitoring treatment. We have applied MT imaging to the cervical spinal cord to see if it is feasible to measure MT ratios (MTR) in this region where pathological changes may result in considerable disability. We studied 12 patients with MS and 12 age- and sex-matched normal controls using a sagittal T2-weighted fast spin-echo sequence with and without an MT pulse. The median value for cervical cord mean MTR measurement in normal controls was 19.30 % units (interquartile range 19.05-19.55), whereas values were significantly lower in MS patients (median = 17.95 % units, interquartile range 17.25-19.00, P = 0.0004). There was a low intrarater variability for repeated mean MTR measurements. We conclude that it is possible to measure MTR in the cervical spinal cord, that a significant reduction occurs in patients with MS, and that there may be a role for this measure in future MS treatment trials. (orig.). With 2 figs., 1 tab.

  12. Uncertainty assessment in gamma spectrometric measurements of plutonium isotope ratios and age

    Energy Technology Data Exchange (ETDEWEB)

    Ramebaeck, H., E-mail: henrik.ramebeck@foi.se [Swedish Defence Research Agency, FOI, Division of CBRN Defence and Security, SE-901 82 Umea (Sweden); Chalmers University of Technology, Department of Chemical and Biological Engineering, Nuclear Chemistry, SE-412 96 Goeteborg (Sweden); Nygren, U.; Tovedal, A. [Swedish Defence Research Agency, FOI, Division of CBRN Defence and Security, SE-901 82 Umea (Sweden); Ekberg, C.; Skarnemark, G. [Chalmers University of Technology, Department of Chemical and Biological Engineering, Nuclear Chemistry, SE-412 96 Goeteborg (Sweden)

    2012-09-15

    A method for the assessment of the combined uncertainty in gamma spectrometric measurements of plutonium composition and age was evaluated. Two materials were measured. Isotope dilution inductively coupled plasma sector field mass spectrometry (ID-ICP-SFMS) was used as a reference method for comparing the results obtained with the gamma spectrometric method for one of the materials. For this material (weapons grade plutonium) the measurement results were in agreement between the two methods for all measurands. Moreover, the combined uncertainty in all isotope ratios considered in this material (R{sub Pu238/Pu239}, R{sub Pu240/Pu239}, R{sub Pu241/Pu239}, and R{sub Am241/Pu241} for age determination) were limited by counting statistics. However, the combined uncertainty for the other material (fuel grade plutonium) were limited by the response fit, which shows that the uncertainty in the response function is important to include in the combined measurement uncertainty of gamma spectrometric measurements of plutonium.

  13. Magnetisation transfer ratio measurement in the cervical spinal cord: a preliminary study in multiple sclerosis

    International Nuclear Information System (INIS)

    Silver, N.C.; Barker, G.J.; Losseff, N.A.; Gawne-Cain, M.L.; MacManus, D.G.; Thompson, A.J.; Miller, D.H.

    1997-01-01

    MRI readily detects the lesions of multiple sclerosis (MS) in the brain and spinal cord. Conventional MRI sequences do not, however, permit distinction between the various pathological characteristics (oedema, demyelination, axonal loss and gliosis) of lesions in MS. Magnetisation transfer (MT) imaging may be more specific in distinguishing the pathologies responsible for disability in MS, namely demyelination and axonal loss, and therefore may have a potential role in monitoring treatment. We have applied MT imaging to the cervical spinal cord to see if it is feasible to measure MT ratios (MTR) in this region where pathological changes may result in considerable disability. We studied 12 patients with MS and 12 age- and sex-matched normal controls using a sagittal T2-weighted fast spin-echo sequence with and without an MT pulse. The median value for cervical cord mean MTR measurement in normal controls was 19.30 % units (interquartile range 19.05-19.55), whereas values were significantly lower in MS patients (median = 17.95 % units, interquartile range 17.25-19.00, P 0.0004). There was a low intrarater variability for repeated mean MTR measurements. We conclude that it is possible to measure MTR in the cervical spinal cord, that a significant reduction occurs in patients with MS, and that there may be a role for this measure in future MS treatment trials. (orig.). With 2 figs., 1 tab

  14. First shock tuning and backscatter measurements for large case-to-capsule ratio beryllium targets

    Science.gov (United States)

    Loomis, Eric; Yi, Austin; Kline, John; Kyrala, George; Simakov, Andrei; Wilson, Doug; Ralph, Joe; Dewald, Eduard; Strozzi, David; Celliers, Peter; Millot, Marius; Tommasini, Riccardo

    2016-10-01

    The current under performance of target implosions on the National Ignition Facility (NIF) has necessitated scaling back from high convergence ratio to access regimes of reduced physics uncertainties. These regimes, we expect, are more predictable by existing radiation hydrodynamics codes giving us a better starting point for isolating key physics questions. One key question is the lack of predictable in-flight and hot spot shape due to a complex hohlraum radiation environment. To achieve more predictable, shape tunable implosions we have designed and fielded a large 4.2 case-to-capsule ratio (CCR) target at the NIF using 6.72 mm diameter Au hohlraums and 1.6 mm diameter Cu-doped Be capsules. Simulations show that at these dimensions during a 10 ns 3-shock laser pulse reaching 270 eV hohlraum temperatures, the interaction between hohlraum and capsule plasma, which at lower CCR lead to beam propagation impedance by artificial plasma stagnation, are reduced. In this talk we will present measurements of early time drive symmetry using two-axis line-imaging velocimetry (VISAR) and streaked radiography measuring velocity of the imploding shell and their comparisons to post-shot calculations using the code HYDRA (Lawrence Livermore National Laboratory).

  15. Measurement of mercury isotopic ratio in stone meteorites by neutron activation analysis

    International Nuclear Information System (INIS)

    Thakur, A.N.

    1997-01-01

    196 Hg and 202 Hg isotopes have been measured by neutron activation analysis in samples of twelve stone meteorites. Hg is extracted from an irradiated sample by stepwise heating. The mercury concentrations vary from 0.07 to 33 ppm. While most of the samples give 196 Hg/ 202 Hg ratios similar to terrestrial value within error limits, in some cases large anomalies are observed. A number of control experiments have been devised, that show the absence of experimental artifacts, during sample preparation, neutron irradiation, chemical separation and counting stages. Several anomalous and normal Hg distillate have been re-irradiated as Hg-diethyl-dithio-carbamate complex to eliminate the influence of neutron self shielding and interfering reactions from matrix elements. The isotopic ratio patterns persist in the distillates too proving that any artifacts during meteorite irradiation and measurement are essentially absent. Both positive and negative anomalies are observed: however, the negative anomalies are much more frequent and abundant. In an extreme case of fine grained magnetic particles of Ambapur Nagla the 196 Hg is apparently absent in the Hg released at 100 deg C. A 2σ 196 Hg/ 202 Hg value is only 6% relative to the monitor. This experiment shows the robustness of neutron activation analysis and suggest some constrains on the formation history of stone meteorites. (author)

  16. Using hyperentanglement to enhance resolution, signal-to-noise ratio, and measurement time

    Science.gov (United States)

    Smith, James F.

    2017-03-01

    A hyperentanglement-based atmospheric imaging/detection system involving only a signal and an ancilla photon will be considered for optical and infrared frequencies. Only the signal photon will propagate in the atmosphere and its loss will be classical. The ancilla photon will remain within the sensor experiencing low loss. Closed form expressions for the wave function, normalization, density operator, reduced density operator, symmetrized logarithmic derivative, quantum Fisher information, quantum Cramer-Rao lower bound, coincidence probabilities, probability of detection, probability of false alarm, probability of error after M measurements, signal-to-noise ratio, quantum Chernoff bound, time-on-target expressions related to probability of error, and resolution will be provided. The effect of noise in every mode will be included as well as loss. The system will provide the basic design for an imaging/detection system functioning at optical or infrared frequencies that offers better than classical angular and range resolution. Optimization for enhanced resolution will be included. The signal-to-noise ratio will be increased by a factor equal to the number of modes employed during the hyperentanglement process. Likewise, the measurement time can be reduced by the same factor. The hyperentanglement generator will typically make use of entanglement in polarization, energy-time, orbital angular momentum and so on. Mathematical results will be provided describing the system's performance as a function of loss mechanisms and noise.

  17. Determination of integrated neutron flux by the measurement of the isotopic ratios of cadmium and gadolinium

    International Nuclear Information System (INIS)

    Tomiyoshi, Irene Akemy

    1982-01-01

    In this work, the possibility of the indirect determination of the integrated neutron flux, through the change of isotopic ratios of cadmium and gadolinium was investigated. The samples of cadmium we/e gadolinium were irradiated in the IEA-Rl reactor. These elements were chosen because they have high thermal neutron absorption cross section which permit the change in the isotopic composition during a short irradiation time to be measured accurately. The isotopic ratios were measured with a thermionic mass spectrometer the silica-gel technique and arrangement with single filament were used for the cadmium analysis, where as the oxi - reduction technique and arrangement with double filaments were used for gadolinium analysis. The mass fractionation effects for cadmium and gadolinium were corrected respectively by the exponential and potential expansion of the isotopic fractionation factor per atomic mass unit. The flux values supplied by the Centro de Operacao e Utilizacao do Reator de Pesquisas do IPEN were extrapolated. These values and the integrated flux values obtained experimentally were compared. (author)

  18. High-precision lead isotope ratio measurement by inductively coupled plasma multiple collector mass spectrometry

    International Nuclear Information System (INIS)

    Walder, A.J.; Furuta, Naoki.

    1993-01-01

    An inductively coupled plasma (ICP) ion source coupled to a magnetic sector mass analyser equipped with seven Faraday detectors has been used to measure the lead isotope ratios in solutions of Sanshiro Pond sediment collected at the University of Tokyo, airborne particulates collected at Shinjuku in Tokyo and Merck multielement standard product number 97279494. A thallium correction technique was utilized to allow a simultaneous correction for mass bias. This work followed an earlier interlaboratory comparison study of the above-mentioned solutions using ICP quadrupole mass spectrometry, and has demonstrated a considerable improvement in analytical precision. The following isotope ratio measurements were recorded. Pond sediment solution containing 82 ng ml -1 lead: 206 Pb/ 204 Pb=17.762±0.014; 206 Pb/ 207 Pb=1.1424±0.0009; 208 Pb/ 204 Pb=37.678±0.034. Airborne particulate solution containing 45 ng ml -1 lead: 206 Pb/ 204 Pb=17.969±0.006; 206 Pb/ 207 Pb=1.1528±0.0003; 208 Pb/ 204 Pb=37.915±0.021. Merck multielement standard solution containing 100 ng ml -1 lead: 206 Pb/ 204 Pb=19.255±0.015; 206 Pb/ 207 Pb=1.2238±0.0004; 208 Pb/ 204 Pb=38.476±0.021 (All errors are given as ±2 standard deviations). (author)

  19. Theory and Measurement of Signal-to-Noise Ratio in Continuous-Wave Noise Radar.

    Science.gov (United States)

    Stec, Bronisław; Susek, Waldemar

    2018-05-06

    Determination of the signal power-to-noise power ratio on the input and output of reception systems is essential to the estimation of their quality and signal reception capability. This issue is especially important in the case when both signal and noise have the same characteristic as Gaussian white noise. This article considers the problem of how a signal-to-noise ratio is changed as a result of signal processing in the correlation receiver of a noise radar in order to determine the ability to detect weak features in the presence of strong clutter-type interference. These studies concern both theoretical analysis and practical measurements of a noise radar with a digital correlation receiver for 9.2 GHz bandwidth. Firstly, signals participating individually in the correlation process are defined and the terms signal and interference are ascribed to them. Further studies show that it is possible to distinguish a signal and a noise on the input and output of a correlation receiver, respectively, when all the considered noises are in the form of white noise. Considering the above, a measurement system is designed in which it is possible to represent the actual conditions of noise radar operation and power measurement of a useful noise signal and interference noise signals—in particular the power of an internal leakage signal between a transmitter and a receiver of the noise radar. The proposed measurement stands and the obtained results show that it is possible to optimize with the use of the equipment and not with the complex processing of a noise signal. The radar parameters depend on its prospective application, such as short- and medium-range radar, ground-penetrating radar, and through-the-wall detection radar.

  20. Determination of /sup 240/Pu//sup 239/Pu ratio in the environmental samples based on the measurement of Lx/. cap alpha. -ray activity ratio

    Energy Technology Data Exchange (ETDEWEB)

    Komura, K.; Sakanoue, M.; Yamamoto, M.

    1984-06-01

    The determination of the /sup 240/Pu//sup 239/Pu isotopic ratio in environmental samples has been attempted by the measurement of the Lx/..cap alpha..-ray activity ratio using a Ge-LEPS (low-energy photon spectrometer) and a surface-barrier Si detector. By this method, interesting data were obtained for various samples collected from Thule, Greenland, Bikini Atoll and Nagasaki, as well as for some soils collected from near and off-site locations of atomic power stations.

  1. Measurement of microenvironmental ozone concentrations in Durham, North Carolina, using a 2B Technologies 205 Federal Equivalent Method monitor and an interference-free 2B Technologies 211 monitor.

    Science.gov (United States)

    Johnson, Ted; Capel, Jim; Ollison, Will

    2014-03-01

    During August and September of 2012, researchers conducted a microenvironmental (ME) monitoring study in Durham, North Carolina, using two 2B Technologies O3 monitors: a dual-beam model 205 Federal Equivalent Method (FEM) 254 nm photometer and a newly developed model 211 interference-free dual-beam photometer. The two monitors were mounted in a wheeled, fan-cooled suitcase together with a battery, a disposable N2O cartridge for the model 211 monitor and filtered sample lines. A scripted technician made paired O3 measurements in a variety of MEs within 2 miles of a fixed-site FEM O3 photometer at the Durham National GuardArmory. The ratio of the 211 to Armory O3 concentrations tended to be lowest (0.8) for 104 outdoor MEs. The mean values of the ratio for in-vehicle MEs tended to fall between 0.2 and 0.7--the mean for all 27 in-car tests was 0.3. The ratio values for indoor MEs tended to be higher when the enclosure was well ventilated. The outdoor ratios tended to be lower when the measurement was made downwind of nearby roadways, likely due to exhaust NO. The in-vehicle ratios tended to be larger with windows open than closed; the smallest occurred with closed windows, active air conditioning, and vent recirculation. The 205 - 211 measurement differences were generally small, with 94% of the 176 sample differences below 5 ppb. Five differences were above 10 ppb with the largest values (173.9 and 63.6 ppb) occurring inside a violin repair shop. Roadway proximity tended to increase the differences for outdoor locations. The largest in-vehicle difference (6 ppb) occurred at a convenience store service station. As addressed in regulatory models, such differences may reduce estimated population O3 exposure by 30-50% in indoor and in-vehicle MEs where individuals spend more than 80% of their time. Computer models used to estimate exposures of human populations-such as the Air Pollution Exposure Model (APEX) developed by the U.S. Environmental Protection Agency-can be

  2. Measurement of soil carbon oxidation state and oxidative ratio by 13C nuclear magnetic resonance

    Science.gov (United States)

    Hockaday, W.C.; Masiello, C.A.; Randerson, J.T.; Smernik, R.J.; Baldock, J.A.; Chadwick, O.A.; Harden, J.W.

    2009-01-01

    The oxidative ratio (OR) of the net ecosystem carbon balance is the ratio of net O2 and CO2 fluxes resulting from photosynthesis, respiration, decomposition, and other lateral and vertical carbon flows. The OR of the terrestrial biosphere must be well characterized to accurately estimate the terrestrial CO2 sink using atmospheric measurements of changing O2 and CO2 levels. To estimate the OR of the terrestrial biosphere, measurements are needed of changes in the OR of aboveground and belowground carbon pools associated with decadal timescale disturbances (e.g., land use change and fire). The OR of aboveground pools can be measured using conventional approaches including elemental analysis. However, measuring the OR of soil carbon pools is technically challenging, and few soil OR data are available. In this paper we test three solid-state nuclear magnetic resonance (NMR) techniques for measuring soil OR, all based on measurements of the closely related parameter, organic carbon oxidation state (Cox). Two of the three techniques make use of a molecular mixing model which converts NMR spectra into concentrations of a standard suite of biological molecules of known C ox. The third technique assigns Cox values to each peak in the NMR spectrum. We assess error associated with each technique using pure chemical compounds and plant biomass standards whose Cox and OR values can be directly measured by elemental analyses. The most accurate technique, direct polarization solid-state 13C NMR with the molecular mixing model, agrees with elemental analyses to ??0.036 Cox units (??0.009 OR units). Using this technique, we show a large natural variability in soil Cox and OR values. Soil Cox values have a mean of -0.26 and a range from -0.45 to 0.30, corresponding to OR values of 1.08 ?? 0.06 and a range from 0.96 to 1.22. We also estimate the OR of the carbon flux from a boreal forest fire. Analysis of soils from nearby intact soil profiles imply that soil carbon losses associated

  3. Optical 'dampening' of the refractive error to axial length ratio: implications for outcome measures in myopia control studies.

    Science.gov (United States)

    Cruickshank, Fiona E; Logan, Nicola S

    2018-05-01

    To gauge the extent to which differences in the refractive error axial length relationship predicted by geometrical optics are observed in actual refractive/biometric data. This study is a retrospective analysis of existing data. Right eye refractive error [RX] and axial length [AXL] data were collected on 343 6-to-7-year-old children [mean 7.18 years (S.D. 0.35)], 294 12-to-13-year-old children [mean 13.12 years (S.D. 0.32)] and 123 young adults aged 18-to-25-years [mean 20.56 years (S.D. 1.91)]. Distance RX was measured with the Shin-Nippon NVision-K 5001 infrared open-field autorefractor. Child participants were cyclopleged prior to data collection (1% Cyclopentolate Hydrochloride). Myopia was defined as a mean spherical equivalent [MSE] ≤-0.50 D. Axial length was measured using the Zeiss IOLMaster 500. Optical modelling was based on ray tracing and manipulation of parameters of a Gullstrand reduced model eye. There was a myopic shift in mean MSE with age (6-7 years +0.87 D, 12-13 years -0.06 D and 18-25 years -1.41 D), associated with an increase in mean AXL (6-7 years 22.70 mm, 12-13 years 23.49 mm and 18-25 years 23.98 mm). There was a significant negative correlation between MSE and AXL for all age groups (all p theory predicts that there will be a reduction in the RX: AXL ratio with longer eyes. The participant data although adhering to this theory show a reduced effect, with eyes with longer axial lengths having a lower refractive error to axial length ratio than predicted by model eye calculations. We propose that in myopia control intervention studies when comparing efficacy, consideration should be given to the dampening effect seen with a longer eye. © 2018 The Authors. Ophthalmic and Physiological Optics published by John Wiley & Sons Ltd on behalf of College of Optometrists.

  4. Particle image velocimetry correlation signal-to-noise ratio metrics and measurement uncertainty quantification

    International Nuclear Information System (INIS)

    Xue, Zhenyu; Charonko, John J; Vlachos, Pavlos P

    2014-01-01

    In particle image velocimetry (PIV) the measurement signal is contained in the recorded intensity of the particle image pattern superimposed on a variety of noise sources. The signal-to-noise-ratio (SNR) strength governs the resulting PIV cross correlation and ultimately the accuracy and uncertainty of the resulting PIV measurement. Hence we posit that correlation SNR metrics calculated from the correlation plane can be used to quantify the quality of the correlation and the resulting uncertainty of an individual measurement. In this paper we extend the original work by Charonko and Vlachos and present a framework for evaluating the correlation SNR using a set of different metrics, which in turn are used to develop models for uncertainty estimation. Several corrections have been applied in this work. The SNR metrics and corresponding models presented herein are expanded to be applicable to both standard and filtered correlations by applying a subtraction of the minimum correlation value to remove the effect of the background image noise. In addition, the notion of a ‘valid’ measurement is redefined with respect to the correlation peak width in order to be consistent with uncertainty quantification principles and distinct from an ‘outlier’ measurement. Finally the type and significance of the error distribution function is investigated. These advancements lead to more robust and reliable uncertainty estimation models compared with the original work by Charonko and Vlachos. The models are tested against both synthetic benchmark data as well as experimental measurements. In this work, U 68.5 uncertainties are estimated at the 68.5% confidence level while U 95 uncertainties are estimated at 95% confidence level. For all cases the resulting calculated coverage factors approximate the expected theoretical confidence intervals, thus demonstrating the applicability of these new models for estimation of uncertainty for individual PIV measurements. (paper)

  5. Particle image velocimetry correlation signal-to-noise ratio metrics and measurement uncertainty quantification

    Science.gov (United States)

    Xue, Zhenyu; Charonko, John J.; Vlachos, Pavlos P.

    2014-11-01

    In particle image velocimetry (PIV) the measurement signal is contained in the recorded intensity of the particle image pattern superimposed on a variety of noise sources. The signal-to-noise-ratio (SNR) strength governs the resulting PIV cross correlation and ultimately the accuracy and uncertainty of the resulting PIV measurement. Hence we posit that correlation SNR metrics calculated from the correlation plane can be used to quantify the quality of the correlation and the resulting uncertainty of an individual measurement. In this paper we extend the original work by Charonko and Vlachos and present a framework for evaluating the correlation SNR using a set of different metrics, which in turn are used to develop models for uncertainty estimation. Several corrections have been applied in this work. The SNR metrics and corresponding models presented herein are expanded to be applicable to both standard and filtered correlations by applying a subtraction of the minimum correlation value to remove the effect of the background image noise. In addition, the notion of a ‘valid’ measurement is redefined with respect to the correlation peak width in order to be consistent with uncertainty quantification principles and distinct from an ‘outlier’ measurement. Finally the type and significance of the error distribution function is investigated. These advancements lead to more robust and reliable uncertainty estimation models compared with the original work by Charonko and Vlachos. The models are tested against both synthetic benchmark data as well as experimental measurements. In this work, {{U}68.5} uncertainties are estimated at the 68.5% confidence level while {{U}95} uncertainties are estimated at 95% confidence level. For all cases the resulting calculated coverage factors approximate the expected theoretical confidence intervals, thus demonstrating the applicability of these new models for estimation of uncertainty for individual PIV measurements.

  6. Ozone mixing ratios inside tropical deep convective clouds from OMI satellite measurements

    Directory of Open Access Journals (Sweden)

    J. R. Ziemke

    2009-01-01

    Full Text Available We have developed a new technique for estimating ozone mixing ratio inside deep convective clouds. The technique uses the concept of an optical centroid cloud pressure that is indicative of the photon path inside clouds. Radiative transfer calculations based on realistic cloud vertical structure as provided by CloudSat radar data show that because deep convective clouds are optically thin near the top, photons can penetrate significantly inside the cloud. This photon penetration coupled with in-cloud scattering produces optical centroid pressures that are hundreds of hPa inside the cloud. We combine measured column ozone and the optical centroid cloud pressure derived using the effects of rotational-Raman scattering to estimate O3 mixing ratio in the upper regions of deep convective clouds. The data are obtained from the Ozone Monitoring Instrument (OMI onboard NASA's Aura satellite. Our results show that low O3 concentrations in these clouds are a common occurrence throughout much of the tropical Pacific. Ozonesonde measurements in the tropics following convective activity also show very low concentrations of O3 in the upper troposphere. These low amounts are attributed to vertical injection of ozone poor oceanic boundary layer air during convection into the upper troposphere followed by convective outflow. Over South America and Africa, O3 mixing ratios inside deep convective clouds often exceed 50 ppbv which are comparable to mean background (cloud-free amounts and are consistent with higher concentrations of injected boundary layer/lower tropospheric O3 relative to the remote Pacific. The Atlantic region in general also consists of higher amounts of O3 precursors due to both biomass burning and lightning. Assuming that O3 is well mixed (i.e., constant mixing ratio with height up to the tropopause, we can estimate the stratospheric column O3 over

  7. Dimensional measurement of micro parts with high aspect ratio in HIT-UOI

    Science.gov (United States)

    Dang, Hong; Cui, Jiwen; Feng, Kunpeng; Li, Junying; Zhao, Shiyuan; Zhang, Haoran; Tan, Jiubin

    2016-11-01

    Micro parts with high aspect ratios have been widely used in different fields including aerospace and defense industries, while the dimensional measurement of these micro parts becomes a challenge in the field of precision measurement and instrument. To deal with this contradiction, several probes for the micro parts precision measurement have been proposed by researchers in Center of Ultra-precision Optoelectronic Instrument (UOI), Harbin Institute of Technology (HIT). In this paper, optical fiber probes with structures of spherical coupling(SC) with double optical fibers, micro focal-length collimation (MFL-collimation) and fiber Bragg grating (FBG) are described in detail. After introducing the sensing principles, both advantages and disadvantages of these probes are analyzed respectively. In order to improve the performances of these probes, several approaches are proposed. A two-dimensional orthogonal path arrangement is propounded to enhance the dimensional measurement ability of MFL-collimation probes, while a high resolution and response speed interrogation method based on differential method is used to improve the accuracy and dynamic characteristics of the FBG probes. The experiments for these special structural fiber probes are given with a focus on the characteristics of these probes, and engineering applications will also be presented to prove the availability of them. In order to improve the accuracy and the instantaneity of the engineering applications, several techniques are used in probe integration. The effectiveness of these fiber probes were therefore verified through both the analysis and experiments.

  8. Amphibious hearing in ringed seals (Pusa hispida): underwater audiograms, aerial audiograms and critical ratio measurements.

    Science.gov (United States)

    Sills, Jillian M; Southall, Brandon L; Reichmuth, Colleen

    2015-07-01

    Ringed seals (Pusa hispida) are semi-aquatic marine mammals with a circumpolar Arctic distribution. In this study, we investigate the amphibious hearing capabilities of ringed seals to provide auditory profiles for this species across the full range of hearing. Using psychophysical methods with two trained ringed seals, detection thresholds for narrowband signals were measured under quiet, carefully controlled environmental conditions to generate aerial and underwater audiograms. Masked underwater thresholds were measured in the presence of octave-band noise to determine critical ratios. Results indicate that ringed seals possess hearing abilities comparable to those of spotted seals (Phoca largha) and harbor seals (Phoca vitulina), and considerably better than previously reported for ringed and harp seals. Best sensitivity was 49 dB re. 1 µPa (12.8 kHz) in water, and -12 dB re. 20 µPa (4.5 kHz) in air, rivaling the acute hearing abilities of some fully aquatic and terrestrial species in their respective media. Critical ratio measurements ranged from 14 dB at 0.1 kHz to 31 dB at 25.6 kHz, suggesting that ringed seals--like other true seals--can efficiently extract signals from background noise across a broad range of frequencies. The work described herein extends similar research on amphibious hearing in spotted seals recently published by the authors. These parallel studies enhance our knowledge of the auditory capabilities of ice-living seals, and inform effective management strategies for these and related species in a rapidly changing Arctic environment. © 2015. Published by The Company of Biologists Ltd.

  9. Semi-automated measurements of heart-to-mediastinum ratio on 123I-MIBG myocardial scintigrams by using image fusion method with chest X-ray images

    Science.gov (United States)

    Kawai, Ryosuke; Hara, Takeshi; Katafuchi, Tetsuro; Ishihara, Tadahiko; Zhou, Xiangrong; Muramatsu, Chisako; Abe, Yoshiteru; Fujita, Hiroshi

    2015-03-01

    MIBG (iodine-123-meta-iodobenzylguanidine) is a radioactive medicine that is used to help diagnose not only myocardial diseases but also Parkinson's diseases (PD) and dementia with Lewy Bodies (DLB). The difficulty of the segmentation around the myocardium often reduces the consistency of measurement results. One of the most common measurement methods is the ratio of the uptake values of the heart to mediastinum (H/M). This ratio will be a stable independent of the operators when the uptake value in the myocardium region is clearly higher than that in background, however, it will be unreliable indices when the myocardium region is unclear because of the low uptake values. This study aims to develop a new measurement method by using the image fusion of three modalities of MIBG scintigrams, 201-Tl scintigrams, and chest radiograms, to increase the reliability of the H/M measurement results. Our automated method consists of the following steps: (1) construct left ventricular (LV) map from 201-Tl myocardium image database, (2) determine heart region in chest radiograms, (3) determine mediastinum region in chest radiograms, (4) perform image fusion of chest radiograms and MIBG scintigrams, and 5) perform H/M measurements on MIBG scintigrams by using the locations of heart and mediastinum determined on the chest radiograms. We collected 165 cases with 201-Tl scintigrams and chest radiograms to construct the LV map. Another 65 cases with MIBG scintigrams and chest radiograms were also collected for the measurements. Four radiological technologists (RTs) manually measured the H/M in the MIBG images. We compared the four RTs' results with our computer outputs by using Pearson's correlation, the Bland-Altman method, and the equivalency test method. As a result, the correlations of the H/M between four the RTs and the computer were 0.85 to 0.88. We confirmed systematic errors between the four RTs and the computer as well as among the four RTs. The variation range of the H

  10. Measurement of extrapolation curves for the secondary pattern of beta radiation Nr. 86 calibrated in rapidity of absorbed dose for tissue equivalent by the Physikalisch Technische Bundesanstalt

    International Nuclear Information System (INIS)

    Alvarez R, J.T.

    1988-10-01

    The following report has as objective to present the obtained results of measuring - with a camera of extrapolation of variable electrodes (CE) - the dose speed absorbed in equivalent fabric given by the group of sources of the secondary pattern of radiation Beta Nr. 86, (PSB), and to compare this results with those presented by the calibration certificates that accompany the PSB extended by the primary laboratory Physikalisch Technische Bundesanstalt, (PTB), of the R.F.A. as well as the uncertainties associated to the measure process. (Author)

  11. ICP-MS with hexapole collision cell for isotope ratio measurements of Ca, Fe, and Se.

    Science.gov (United States)

    Boulyga, S F; Becker, J S

    2001-07-01

    To avoid mass interferences on analyte ions caused by argon ions and argon molecular ions via reactions with collision gases, an rf hexapole filled with helium and hydrogen has been used in inductively coupled plasma mass spectrometry (ICP-MS), and its performance has been studied. Up to tenfold improvement in sensitivity was observed for heavy elements (m > 100 u), because of better ion transmission through the hexapole ion guide. A reduction of argon ions Ar+ and the molecular ions of argon ArX+ (X = O, Ar) by up to three orders of magnitude was achieved in a hexapole collision cell of an ICP-MS ("Platform ICP", Micromass, Manchester, UK) as a result of gas-phase reactions with hydrogen when the hexapole bias (HB) was set to 0 V; at an HB of 1.6 V argon, and argon-based ions of masses 40 u, 56 u, and 80 u, were reduced by approximately four, two, and five orders of magnitude, respectively. The signal-to-noise ratio 80Se/ 40Ar2+ was improved by more than five orders of magnitude under optimized experimental conditions. Dependence of mass discrimination on collision-cell properties was studied in the mass range 10 u (boron) to 238 u (uranium). Isotopic analysis of the elements affected by mass-spectrometric interference, Ca, Fe, and Se, was performed using a Meinhard nebulizer and an ultrasonic nebulizer (USN). The measured isotope ratios were comparable with tabulated values from IUPAC. Precision of 0.26%, 0.19%, and 0.12%, respectively, and accuracy of 0.13% 0.25%, and 0.92%, respectively, was achieved for isotope ratios 44Ca/ 40Ca and 56Fe/57Fe in 10 microg L(-1) solution nebulized by means of a USN and for 78Se/80Se in 100 microg L(-1) solution nebulized by means of a Meinhard nebulizer.

  12. Uranium Age Determination by Measuring the 230Th / 234U Ratio

    International Nuclear Information System (INIS)

    LAMONT, STEPHEN P.

    2004-01-01

    A radiochemical isotope dilution mass spectrometry method has been developed to determine the age of uranium materials. The amount of 230Th activity, the first progeny of 234U, that had grown into a small uranium metal sample was used to determine the elapsed time since the material was last radiochemically purified. To preserve the sample, only a small amount of oxidized uranium was removed from the surface of the sample and dissolved. Aliquots of the dissolved sample were spiked with 233U tracer and radiochemically purified by anion-exchange chromatography. The 234U isotopic concentration was then determined by thermal ionization mass spectrometry. Additional aliquots of the sample were spiked with 229Th tracer, and the thorium was purified using two sequential anion-exchange chromatography separations. The isotopic concentrations of 230Th and 232Th were determined by TIMS. The lack of any 232Th confirmed the assumption that all thorium was removed from the uranium sample at the time of purification. The 230Th and 234U mass concentrations were converted to activities and the 230Th/234U ratio for the sample was calculated. The experimental 230Th/234U ratio showed the uranium in this sample was radiochemically purified in about 1945. Isotope dilution thermal ionization mass spectrometry has sufficient sensitivity to determine the age of 100 samples of uranium. This method could certainly be employed as a nuclear forensic method to determine the age of small quantities of uranium metal or salts. Accurate determination of the ultra-trace 230Th radiochemically separated from the uranium is possible due to the use of 229Th as an isotope dilution tracer. The precision in the experimental age of the uranium could be improved by making additional replicate measurements of the 230Th/234U isotopic ratio or using a larger initial sample

  13. Measurement of relative L X-ray intensity ratio following radioactive decay and photoionization

    Energy Technology Data Exchange (ETDEWEB)

    Yalcin, P. [Department of Science Education, Faculty of Education, Erzincan University, 24030 Erzincan (Turkey)], E-mail: pasayalcin@hotmail.com; Porikli, S.; Kurucu, Y.; Sahin, Y. [Department of Physics, Faculty of Sciences, Atatuerk University, 25240 Erzurum (Turkey)

    2008-05-22

    The measurements of the L X-ray intensity ratio I(L{alpha})/I(L{beta}), I(L{alpha})/I(L{gamma}), I(L{alpha})/I(L{iota}), I(L{beta})/I(L{gamma}) and I(L{iota})/I(L{gamma}) for elements Dy, Ho, Yb, W, Hg, Tl and Pb were experimentally determined both by photon excitation, in which 59.5 keV {gamma}-rays from a filtered radioisotope {sup 241}Am was used, and by the radioactive decay of {sup 160}Tb, {sup 160}Er, {sup 173}Lu, {sup 182}Re, {sup 201}Tl, {sup 203}Pb and {sup 207}Bi. L X-rays emitted by samples were counted by a Si(Li) detector with resolution 160 eV at 5.9 keV. Obtained values were compared with the calculated theoretical values. Theoretical values of the I(L{alpha}/L{beta}), I(L{alpha}/L{gamma}), I(L{alpha}/L{iota}), I(L{beta}/L{gamma}) and I(L{iota}/L{gamma}) intensity ratios were calculated using theoretically tabulated values of subshell photoionization cross-section, fluorescence yield, fractional X-ray emission rates, Coster-Kronig transition probabilities. It was observed that present values agree with previous theoretical and other available experimental results.

  14. Precision measurement of the ratio of the $\\Lambda^0_b$ to $\\overline{B}^0$ lifetimes

    CERN Document Server

    Aaij, Roel; Adinolfi, Marco; Affolder, Anthony; Ajaltouni, Ziad; Albrecht, Johannes; Alessio, Federico; Alexander, Michael; Ali, Suvayu; Alkhazov, Georgy; Alvarez Cartelle, Paula; Alves Jr, Antonio; Amato, Sandra; Amerio, Silvia; Amhis, Yasmine; Anderlini, Lucio; Anderson, Jonathan; Andreassen, Rolf; Andreotti, Mirco; Andrews, Jason; Appleby, Robert; Aquines Gutierrez, Osvaldo; Archilli, Flavio; Artamonov, Alexander; Artuso, Marina; Aslanides, Elie; Auriemma, Giulio; Baalouch, Marouen; Bachmann, Sebastian; Back, John; Badalov, Alexey; Balagura, Vladislav; Baldini, Wander; Barlow, Roger; Barschel, Colin; Barsuk, Sergey; Barter, William; Batozskaya, Varvara; Bauer, Thomas; Bay, Aurelio; Beddow, John; Bedeschi, Franco; Bediaga, Ignacio; Belogurov, Sergey; Belous, Konstantin; Belyaev, Ivan; Ben-Haim, Eli; Bencivenni, Giovanni; Benson, Sean; Benton, Jack; Berezhnoy, Alexander; Bernet, Roland; Bettler, Marc-Olivier; van Beuzekom, Martinus; Bien, Alexander; Bifani, Simone; Bird, Thomas; Bizzeti, Andrea; Bjørnstad, Pål Marius; Blake, Thomas; Blanc, Frédéric; Blouw, Johan; Blusk, Steven; Bocci, Valerio; Bondar, Alexander; Bondar, Nikolay; Bonivento, Walter; Borghi, Silvia; Borgia, Alessandra; Borsato, Martino; Bowcock, Themistocles; Bowen, Espen Eie; Bozzi, Concezio; Brambach, Tobias; van den Brand, Johannes; Bressieux, Joël; Brett, David; Britsch, Markward; Britton, Thomas; Brook, Nicholas; Brown, Henry; Bursche, Albert; Busetto, Giovanni; Buytaert, Jan; Cadeddu, Sandro; Calabrese, Roberto; Callot, Olivier; Calvi, Marta; Calvo Gomez, Miriam; Camboni, Alessandro; Campana, Pierluigi; Campora Perez, Daniel; Caponio, Francesco; Carbone, Angelo; Carboni, Giovanni; Cardinale, Roberta; Cardini, Alessandro; Carranza-Mejia, Hector; Carson, Laurence; Carvalho Akiba, Kazuyoshi; Casse, Gianluigi; Cassina, Lorenzo; Castillo Garcia, Lucia; Cattaneo, Marco; Cauet, Christophe; Cenci, Riccardo; Charles, Matthew; Charpentier, Philippe; Cheung, Shu-Faye; Chiapolini, Nicola; Chrzaszcz, Marcin; Ciba, Krzystof; Cid Vidal, Xabier; Ciezarek, Gregory; Clarke, Peter; Clemencic, Marco; Cliff, Harry; Closier, Joel; Coca, Cornelia; Coco, Victor; Cogan, Julien; Cogneras, Eric; Collins, Paula; Comerma-Montells, Albert; Contu, Andrea; Cook, Andrew; Coombes, Matthew; Coquereau, Samuel; Corti, Gloria; Counts, Ian; Couturier, Benjamin; Cowan, Greig; Craik, Daniel Charles; Cruz Torres, Melissa Maria; Cunliffe, Samuel; Currie, Robert; D'Ambrosio, Carmelo; Dalseno, Jeremy; David, Pascal; David, Pieter; Davis, Adam; De Bonis, Isabelle; De Bruyn, Kristof; De Capua, Stefano; De Cian, Michel; De Miranda, Jussara; De Paula, Leandro; De Silva, Weeraddana; De Simone, Patrizia; Decamp, Daniel; Deckenhoff, Mirko; Del Buono, Luigi; Déléage, Nicolas; Derkach, Denis; Deschamps, Olivier; Dettori, Francesco; Di Canto, Angelo; Dijkstra, Hans; Donleavy, Stephanie; Dordei, Francesca; Dorigo, Mirco; Dorosz, Piotr; Dosil Suárez, Alvaro; Dossett, David; Dovbnya, Anatoliy; Dupertuis, Frederic; Durante, Paolo; Dzhelyadin, Rustem; Dziurda, Agnieszka; Dzyuba, Alexey; Easo, Sajan; Egede, Ulrik; Egorychev, Victor; Eidelman, Semen; Eisenhardt, Stephan; Eitschberger, Ulrich; Ekelhof, Robert; Eklund, Lars; El Rifai, Ibrahim; Elsasser, Christian; Esen, Sevda; Falabella, Antonio; Färber, Christian; Farinelli, Chiara; Farry, Stephen; Ferguson, Dianne; Fernandez Albor, Victor; Ferreira Rodrigues, Fernando; Ferro-Luzzi, Massimiliano; Filippov, Sergey; Fiore, Marco; Fiorini, Massimiliano; Fitzpatrick, Conor; Fontana, Marianna; Fontanelli, Flavio; Forty, Roger; Francisco, Oscar; Frank, Markus; Frei, Christoph; Frosini, Maddalena; Fu, Jinlin; Furfaro, Emiliano; Gallas Torreira, Abraham; Galli, Domenico; Gambetta, Silvia; Gandelman, Miriam; Gandini, Paolo; Gao, Yuanning; Garofoli, Justin; Garra Tico, Jordi; Garrido, Lluis; Gaspar, Clara; Gauld, Rhorry; Gavardi, Laura; Gersabeck, Evelina; Gersabeck, Marco; Gershon, Timothy; Ghez, Philippe; Gianelle, Alessio; Giani', Sebastiana; Gibson, Valerie; Giubega, Lavinia-Helena; Gligorov, Vladimir; Göbel, Carla; Golubkov, Dmitry; Golutvin, Andrey; Gomes, Alvaro; Gordon, Hamish; Grabalosa Gándara, Marc; Graciani Diaz, Ricardo; Granado Cardoso, Luis Alberto; Graugés, Eugeni; Graziani, Giacomo; Grecu, Alexandru; Greening, Edward; Gregson, Sam; Griffith, Peter; Grillo, Lucia; Grünberg, Oliver; Gui, Bin; Gushchin, Evgeny; Guz, Yury; Gys, Thierry; Hadjivasiliou, Christos; Haefeli, Guido; Haen, Christophe; Hafkenscheid, Tom; Haines, Susan; Hall, Samuel; Hamilton, Brian; Hampson, Thomas; Hansmann-Menzemer, Stephanie; Harnew, Neville; Harnew, Samuel; Harrison, Jonathan; Hartmann, Thomas; He, Jibo; Head, Timothy; Heijne, Veerle; Hennessy, Karol; Henrard, Pierre; Henry, Louis; Hernando Morata, Jose Angel; van Herwijnen, Eric; Heß, Miriam; Hicheur, Adlène; Hill, Donal; Hoballah, Mostafa; Hombach, Christoph; Hulsbergen, Wouter; Hunt, Philip; Hussain, Nazim; Hutchcroft, David; Hynds, Daniel; Idzik, Marek; Ilten, Philip; Jacobsson, Richard; Jaeger, Andreas; Jans, Eddy; Jaton, Pierre; Jawahery, Abolhassan; Jing, Fanfan; John, Malcolm; Johnson, Daniel; Jones, Christopher; Joram, Christian; Jost, Beat; Jurik, Nathan; Kaballo, Michael; Kandybei, Sergii; Kanso, Wallaa; Karacson, Matthias; Karbach, Moritz; Kelsey, Matthew; Kenyon, Ian; Ketel, Tjeerd; Khanji, Basem; Khurewathanakul, Chitsanu; Klaver, Suzanne; Kochebina, Olga; Komarov, Ilya; Koopman, Rose; Koppenburg, Patrick; Korolev, Mikhail; Kozlinskiy, Alexandr; Kravchuk, Leonid; Kreplin, Katharina; Kreps, Michal; Krocker, Georg; Krokovny, Pavel; Kruse, Florian; Kucharczyk, Marcin; Kudryavtsev, Vasily; Kurek, Krzysztof; Kvaratskheliya, Tengiz; La Thi, Viet Nga; Lacarrere, Daniel; Lafferty, George; Lai, Adriano; Lambert, Dean; Lambert, Robert W; Lanciotti, Elisa; Lanfranchi, Gaia; Langenbruch, Christoph; Langhans, Benedikt; Latham, Thomas; Lazzeroni, Cristina; Le Gac, Renaud; van Leerdam, Jeroen; Lees, Jean-Pierre; Lefèvre, Regis; Leflat, Alexander; Lefrançois, Jacques; Leo, Sabato; Leroy, Olivier; Lesiak, Tadeusz; Leverington, Blake; Li, Yiming; Liles, Myfanwy; Lindner, Rolf; Linn, Christian; Lionetto, Federica; Liu, Bo; Liu, Guoming; Lohn, Stefan; Longstaff, Ian; Lopes, Jose; Lopez-March, Neus; Lowdon, Peter; Lu, Haiting; Lucchesi, Donatella; Luo, Haofei; Luppi, Eleonora; Lupton, Oliver; Machefert, Frederic; Machikhiliyan, Irina V; Maciuc, Florin; Maev, Oleg; Malde, Sneha; Manca, Giulia; Mancinelli, Giampiero; Manzali, Matteo; Maratas, Jan; Marconi, Umberto; Marin Benito, Carla; Marino, Pietro; Märki, Raphael; Marks, Jörg; Martellotti, Giuseppe; Martens, Aurelien; Martín Sánchez, Alexandra; Martinelli, Maurizio; Martinez Santos, Diego; Martinez Vidal, Fernando; Martins Tostes, Danielle; Massafferri, André; Matev, Rosen; Mathe, Zoltan; Matteuzzi, Clara; Mazurov, Alexander; McCann, Michael; McCarthy, James; McNab, Andrew; McNulty, Ronan; McSkelly, Ben; Meadows, Brian; Meier, Frank; Meissner, Marco; Merk, Marcel; Milanes, Diego Alejandro; Minard, Marie-Noelle; Molina Rodriguez, Josue; Monteil, Stephane; Moran, Dermot; Morandin, Mauro; Morawski, Piotr; Mordà, Alessandro; Morello, Michael Joseph; Mountain, Raymond; Muheim, Franz; Müller, Katharina; Muresan, Raluca; Muryn, Bogdan; Muster, Bastien; Naik, Paras; Nakada, Tatsuya; Nandakumar, Raja; Nasteva, Irina; Needham, Matthew; Neri, Nicola; Neubert, Sebastian; Neufeld, Niko; Nguyen, Anh Duc; Nguyen, Thi-Dung; Nguyen-Mau, Chung; Nicol, Michelle; Niess, Valentin; Niet, Ramon; Nikitin, Nikolay; Nikodem, Thomas; Novoselov, Alexey; Oblakowska-Mucha, Agnieszka; Obraztsov, Vladimir; Oggero, Serena; Ogilvy, Stephen; Okhrimenko, Oleksandr; Oldeman, Rudolf; Onderwater, Gerco; Orlandea, Marius; Otalora Goicochea, Juan Martin; Owen, Patrick; Oyanguren, Maria Arantza; Pal, Bilas Kanti; Palano, Antimo; Palombo, Fernando; Palutan, Matteo; Panman, Jacob; Papanestis, Antonios; Pappagallo, Marco; Pappalardo, Luciano; Parkes, Christopher; Parkinson, Christopher John; Passaleva, Giovanni; Patel, Girish; Patel, Mitesh; Patrignani, Claudia; Pavel-Nicorescu, Carmen; Pazos Alvarez, Antonio; Pearce, Alex; Pellegrino, Antonio; Pepe Altarelli, Monica; Perazzini, Stefano; Perez Trigo, Eliseo; Perret, Pascal; Perrin-Terrin, Mathieu; Pescatore, Luca; Pesen, Erhan; Pessina, Gianluigi; Petridis, Konstantin; Petrolini, Alessandro; Picatoste Olloqui, Eduardo; Pietrzyk, Boleslaw; Pilař, Tomas; Pinci, Davide; Pistone, Alessandro; Playfer, Stephen; Plo Casasus, Maximo; Polci, Francesco; Poluektov, Anton; Polycarpo, Erica; Popov, Alexander; Popov, Dmitry; Popovici, Bogdan; Potterat, Cédric; Powell, Andrew; Prisciandaro, Jessica; Pritchard, Adrian; Prouve, Claire; Pugatch, Valery; Puig Navarro, Albert; Punzi, Giovanni; Qian, Wenbin; Rachwal, Bartolomiej; Rademacker, Jonas; Rakotomiaramanana, Barinjaka; Rama, Matteo; Rangel, Murilo; Raniuk, Iurii; Rauschmayr, Nathalie; Raven, Gerhard; Reichert, Stefanie; Reid, Matthew; dos Reis, Alberto; Ricciardi, Stefania; Richards, Alexander; Rinnert, Kurt; Rives Molina, Vincente; Roa Romero, Diego; Robbe, Patrick; Roberts, Douglas; Rodrigues, Ana Barbara; Rodrigues, Eduardo; Rodriguez Perez, Pablo; Roiser, Stefan; Romanovsky, Vladimir; Romero Vidal, Antonio; Rotondo, Marcello; Rouvinet, Julien; Ruf, Thomas; Ruffini, Fabrizio; Ruiz, Hugo; Ruiz Valls, Pablo; Sabatino, Giovanni; Saborido Silva, Juan Jose; Sagidova, Naylya; Sail, Paul; Saitta, Biagio; Salustino Guimaraes, Valdir; Sanmartin Sedes, Brais; Santacesaria, Roberta; Santamarina Rios, Cibran; Santovetti, Emanuele; Sapunov, Matvey; Sarti, Alessio; Satriano, Celestina; Satta, Alessia; Savrie, Mauro; Savrina, Darya; Schiller, Manuel; Schindler, Heinrich; Schlupp, Maximilian; Schmelling, Michael; Schmidt, Burkhard; Schneider, Olivier; Schopper, Andreas; Schune, Marie Helene; Schwemmer, Rainer; Sciascia, Barbara; Sciubba, Adalberto; Seco, Marcos; Semennikov, Alexander; Senderowska, Katarzyna; Sepp, Indrek; Serra, Nicola; Serrano, Justine; Seyfert, Paul; Shapkin, Mikhail; Shapoval, Illya; Shcheglov, Yury; Shears, Tara; Shekhtman, Lev; Shevchenko, Oksana; Shevchenko, Vladimir; Shires, Alexander; Silva Coutinho, Rafael; Simi, Gabriele; Sirendi, Marek; Skidmore, Nicola; Skwarnicki, Tomasz; Smith, Anthony; Smith, Edmund; Smith, Eluned; Smith, Jackson; Smith, Mark; Snoek, Hella; Sokoloff, Michael; Soler, Paul; Soomro, Fatima; Souza, Daniel; Souza De Paula, Bruno; Spaan, Bernhard; Sparkes, Ailsa; Spinella, Franco; Spradlin, Patrick; Stagni, Federico; Stahl, Sascha; Steinkamp, Olaf; Stevenson, Scott; Stoica, Sabin; Stone, Sheldon; Storaci, Barbara; Stracka, Simone; Straticiuc, Mihai; Straumann, Ulrich; Stroili, Roberto; Subbiah, Vijay Kartik; Sun, Liang; Sutcliffe, William; Swientek, Stefan; Syropoulos, Vasileios; Szczekowski, Marek; Szczypka, Paul; Szilard, Daniela; Szumlak, Tomasz; T'Jampens, Stephane; Teklishyn, Maksym; Tellarini, Giulia; Teodorescu, Eliza; Teubert, Frederic; Thomas, Christopher; Thomas, Eric; van Tilburg, Jeroen; Tisserand, Vincent; Tobin, Mark; Tolk, Siim; Tomassetti, Luca; Tonelli, Diego; Topp-Joergensen, Stig; Torr, Nicholas; Tournefier, Edwige; Tourneur, Stephane; Tran, Minh Tâm; Tresch, Marco; Tsaregorodtsev, Andrei; Tsopelas, Panagiotis; Tuning, Niels; Ubeda Garcia, Mario; Ukleja, Artur; Ustyuzhanin, Andrey; Uwer, Ulrich; Vagnoni, Vincenzo; Valenti, Giovanni; Vallier, Alexis; Vazquez Gomez, Ricardo; Vazquez Regueiro, Pablo; Vázquez Sierra, Carlos; Vecchi, Stefania; Velthuis, Jaap; Veltri, Michele; Veneziano, Giovanni; Vesterinen, Mika; Viaud, Benoit; Vieira, Daniel; Vilasis-Cardona, Xavier; Vollhardt, Achim; Volyanskyy, Dmytro; Voong, David; Vorobyev, Alexey; Vorobyev, Vitaly; Voß, Christian; Voss, Helge; de Vries, Jacco; Waldi, Roland; Wallace, Charlotte; Wallace, Ronan; Wandernoth, Sebastian; Wang, Jianchun; Ward, David; Watson, Nigel; Webber, Adam Dane; Websdale, David; Whitehead, Mark; Wicht, Jean; Wiechczynski, Jaroslaw; Wiedner, Dirk; Wilkinson, Guy; Williams, Matthew; Williams, Mike; Wilson, Fergus; Wimberley, Jack; Wishahi, Julian; Wislicki, Wojciech; Witek, Mariusz; Wormser, Guy; Wotton, Stephen; Wright, Simon; Wu, Suzhi; Wyllie, Kenneth; Xie, Yuehong; Xing, Zhou; Yang, Zhenwei; Yuan, Xuhao; Yushchenko, Oleg; Zangoli, Maria; Zavertyaev, Mikhail; Zhang, Feng; Zhang, Liming; Zhang, Wen Chao; Zhang, Yanxi; Zhelezov, Alexey; Zhokhov, Anatoly; Zhong, Liang; Zvyagin, Alexander

    2014-01-01

    The LHCb measurement of the lifetime ratio of the $\\Lambda^0_b$ to the $\\overline{B}^0$ meson is updated using data corresponding to an integrated luminosity of 3.0 fb$^{-1}$ collected using 7 and 8 TeV centre-of-mass energy $pp$ collisions at the LHC. The decay modes used are $\\overline{\\Lambda}^0_b \\to J/\\psi p K^-$ and $\\overline{B}^0 \\to J/\\psi \\pi^+ K^-$, where the $\\pi^+K^-$ mass is consistent with that of the $\\overline{K}^{*0}(892)$ meson. The lifetime ratio is determined with unprecedented precision to be $0.974\\pm0.006\\pm0.004$, where the first uncertainty is statistical and the second systematic. This result is in agreement with original theoretical predictions based on the heavy quark expansion. Using the current world average of the $\\overline{B}^0$ lifetime, the $\\Lambda^0_b$ lifetime is found to be $1.479 \\pm 0.009 \\pm 0.010$ ps.

  15. Measurement of fluorescent probes concentration ratio in the cerebrospinal fluid for early detection of Alzheimer's disease

    Science.gov (United States)

    Harbater, Osnat; Gannot, Israel

    2014-03-01

    The pathogenic process of Alzheimer's Disease (AD), characterized by amyloid plaques and neurofibrillary tangles in the brain, begins years before the clinical diagnosis. Here, we suggest a novel method which may detect AD up to nine years earlier than current exams, minimally invasive, with minimal risk, pain and side effects. The method is based on previous reports which relate the concentrations of biomarkers in the Cerebrospinal Fluid (CSF) (Aβ and Tau proteins) to the future development of AD in mild cognitive impairment patients. Our method, which uses fluorescence measurements of the relative concentrations of the CSF biomarkers, replaces the lumbar puncture process required for CSF drawing. The process uses a miniature needle coupled trough an optical fiber to a laser source and a detector. The laser radiation excites fluorescent probes which were prior injected and bond to the CSF biomarkers. Using the ratio between the fluorescence intensities emitted from the two biomarkers, which is correlated to their concentration ratio, the patient's risk of developing AD is estimated. A theoretical model was developed and validated using Monte Carlo simulations, demonstrating the relation between fluorescence emission and biomarker concentration. The method was tested using multi-layered tissue phantoms simulating the epidural fat, the CSF in the sub-arachnoid space and the bone. These phantoms were prepared with different scattering and absorption coefficients, thicknesses and fluorescence concentrations in order to simulate variations in human anatomy and in the needle location. The theoretical and in-vitro results are compared and the method's accuracy is discussed.

  16. Estimating back to front ratio of wire screen for measurement of thoron decay products

    International Nuclear Information System (INIS)

    Koli, Amruta; Khandare, Pallavi; Joshi, Manish; Mariam; Khan, Arshad; Sapra, B.K.

    2016-01-01

    Wire screens are widely used for measuring the fine fraction of radon/thoron decay products. Their capture efficiencies are generally defined at low aerosol concentration conditions as well as at low sampling flow rates. Effect of changes in sampling flow rate and aerosol concentration on wire screen capture efficiencies and counting correction factor has been studied in this work. Controlled experiments have been conducted using two different mesh sizes at two different aerosol concentration conditions. Experimental results were compared with the existing theories for capture efficiencies of wire screens given by Cheng and Yeh (1980) and Alonso et al. (2001); and semi empirical relation for the front to total ratio given by Solomon and Ren (1992). Theoretical predictions have been found to be relatively close to the experimental findings for moderate aerosol conditions but disagreement was observed in case of high aerosol concentration. The possible reasons for these differences have been discussed in this work. - Highlights: • Effect of Fiber Reynolds number on capture efficiency and back to front ratio of wire screen. • Experiments with Thoron decay products at moderate and elevated aerosol concentrations. • Comparison with theoretical estimates. • Fair agreement observed for moderate aerosol concentration.

  17. Measurement Equivalence of the Patient Reported Outcomes Measurement Information System® (PROMIS®) Applied Cognition - General Concerns, Short Forms in Ethnically Diverse Groups.

    Science.gov (United States)

    Fieo, Robert; Ocepek-Welikson, Katja; Kleinman, Marjorie; Eimicke, Joseph P; Crane, Paul K; Cella, David; Teresi, Jeanne A

    2016-01-01

    The goals of these analyses were to examine the psychometric properties and measurement equivalence of a self-reported cognition measure, the Patient Reported Outcome Measurement Information System ® (PROMIS ® ) Applied Cognition - General Concerns short form. These items are also found in the PROMIS Cognitive Function (version 2) item bank. This scale consists of eight items related to subjective cognitive concerns. Differential item functioning (DIF) analyses of gender, education, race, age, and (Spanish) language were performed using an ethnically diverse sample ( n = 5,477) of individuals with cancer. This is the first analysis examining DIF in this item set across ethnic and racial groups. DIF hypotheses were derived by asking content experts to indicate whether they posited DIF for each item and to specify the direction. The principal DIF analytic model was item response theory (IRT) using the graded response model for polytomous data, with accompanying Wald tests and measures of magnitude. Sensitivity analyses were conducted using ordinal logistic regression (OLR) with a latent conditioning variable. IRT-based reliability, precision and information indices were estimated. DIF was identified consistently only for the item, brain not working as well as usual. After correction for multiple comparisons, this item showed significant DIF for both the primary and sensitivity analyses. Black respondents and Hispanics in comparison to White non-Hispanic respondents evidenced a lower conditional probability of endorsing the item, brain not working as well as usual. The same pattern was observed for the education grouping variable: as compared to those with a graduate degree, conditioning on overall level of subjective cognitive concerns, those with less than high school education also had a lower probability of endorsing this item. DIF was also observed for age for two items after correction for multiple comparisons for both the IRT and OLR-based models: "I have had

  18. Measurement and properties of the dose-area product ratio in external small-beam radiotherapy.

    Science.gov (United States)

    Niemelä, Jarkko; Partanen, Mari; Ojala, Jarkko; Sipilä, Petri; Björkqvist, Mikko; Kapanen, Mika; Keyriläinen, Jani

    2017-06-21

    In small-beam radiation therapy (RT) the measurement of the beam quality parameter, i.e. the tissue-phantom ratio or TPR 20,10 , using a conventional point detector is a challenge. To obtain reliable results, one has to consider potential sources of error, including volume averaging and adjustment of the point detector into the narrow beam. To overcome these challenges, a different type of beam quality parameter in small beams was studied, namely the dose-area product ratio, or DAPR 20,10 . With this method, the measurement of a dose-area product (DAP) using a large-area plane-parallel chamber (LAC) eliminates the uncertainties in detector positioning and volume averaging that are present when using a point detector. In this study, the properties of the DAPR 20,10 of a cone-collimated 6 MV photon beam were investigated using Monte Carlo (MC) calculations and the obtained values were compared to measurements obtained using two LAC detectors, PTW Type 34073 and PTW Type 34070. In addition, the possibility of determining the DAP using EBT3 film and a Razor diode detector was studied. The determination of the DAPR 20,10 value was found to be feasible in external small-beam radiotherapy using cone-collimated beams with diameters from 4-40 mm, based on the results of the two LACs, the MC calculations and the Razor diode. The measurements indicated a constant DAPR 20,10 value for fields 20-40 mm in diameter, with a maximum relative change of 0.6%, but an increase of 7.0% for fields from 20-4 mm in diameter for the PTW Type 34070 chamber. Simulations and measurements showed an increase of DAPR 20,10 with increasing LAC size or dose integral area for the studied 4-40 mm cone-collimated 6 MV photon beams. This has the consequence that there should be a reference to the size of the used LAC active area or the DAP integration area with the reported DAPR 20,10 value.

  19. Oceans circulation and electron cyclotron resonance sources: Measurement of the AR-39 isotopic ratio in Seawater

    International Nuclear Information System (INIS)

    Gaelens, M.; Loiselet, M.; Ryckewaert, G.; Pardo, R.C.; Scott, R.H.; Vondrasek, R.; Collon, Ph.; Kutchera, W.

    2004-01-01

    The radionuclide 39 Ar is produced in the atmosphere by cosmic rays and has an isotopic abundance of 8.1x10 -16 . Because its half life (T 1/2 =269 years) is well matched to the time periods involved in the oceanic currents around the Earth, the measurement of the 39 Ar isotopic ratio is an ideal tool to date ocean water from different depths. It would complement the information gained by the 14 C measurements (T 1/2 =5730 years). However, the measurement of the isotopic ratio 39 Ar/ 40 Ar is a technical challenge: 1 L of modern ocean water contains ∼6500 atoms of 39 Ar, and produces ∼17 decays per year. Although it has been possible to detect the 39 Ar decays in large volumes of sea water by using the low level counting technique, the possibility of measuring the number of 39 Ar atoms faster and in smaller samples using the accelerator mass spectrometry (AMS) technique would be a major breakthrough for this type of measurement. The development of a viable AMS method for 39 Ar has been underway for several years at Argonne National Laboratory, and is presently hampered by the presence of stable 39 K ions coming from the ion source. Although the intensity of this isobaric contaminant is low (∼pA extracted from the source), it has to be compared with the 39 Ar beam intensity (atoms per minutes). In order to separate these two beams (whose mass difference is only 1.6x10 -5 ), the intensity of the 39 K beam coming from the ion source has to be reduced by several orders of magnitude. This reduction has been investigated both at Argonne National Laboratory and at Louvain-la-Neuve. Two techniques have been tried out. In the first, a quartz liner is used to provide a clean surface, while in the second these impurities are buried in a SiO 2 layer formed in situ by running the source with a mixture of silane and oxygen. The 39 K background has been reduced by a factor of 100 with these treatments. These techniques and their results obtained both at Argonne and Louvain

  20. Measurement and properties of the dose-area product ratio in external small-beam radiotherapy

    Science.gov (United States)

    Niemelä, Jarkko; Partanen, Mari; Ojala, Jarkko; Sipilä, Petri; Björkqvist, Mikko; Kapanen, Mika; Keyriläinen, Jani

    2017-06-01

    In small-beam radiation therapy (RT) the measurement of the beam quality parameter, i.e. the tissue-phantom ratio or TPR20,10, using a conventional point detector is a challenge. To obtain reliable results, one has to consider potential sources of error, including volume averaging and adjustment of the point detector into the narrow beam. To overcome these challenges, a different type of beam quality parameter in small beams was studied, namely the dose-area product ratio, or DAPR20,10. With this method, the measurement of a dose-area product (DAP) using a large-area plane-parallel chamber (LAC) eliminates the uncertainties in detector positioning and volume averaging that are present when using a point detector. In this study, the properties of the DAPR20,10 of a cone-collimated 6 MV photon beam were investigated using Monte Carlo (MC) calculations and the obtained values were compared to measurements obtained using two LAC detectors, PTW Type 34073 and PTW Type 34070. In addition, the possibility of determining the DAP using EBT3 film and a Razor diode detector was studied. The determination of the DAPR20,10 value was found to be feasible in external small-beam radiotherapy using cone-collimated beams with diameters from 4-40 mm, based on the results of the two LACs, the MC calculations and the Razor diode. The measurements indicated a constant DAPR20,10 value for fields 20-40 mm in diameter, with a maximum relative change of 0.6%, but an increase of 7.0% for fields from 20-4 mm in diameter for the PTW Type 34070 chamber. Simulations and measurements showed an increase of DAPR20,10 with increasing LAC size or dose integral area for the studied 4-40 mm cone-collimated 6 MV photon beams. This has the consequence that there should be a reference to the size of the used LAC active area or the DAP integration area with the reported DAPR20,10 value.

  1. Experimental study on occurrence-time ratio measurements of air entrainment in a suction sump

    International Nuclear Information System (INIS)

    Inagaki, K; Funaki, J; Hirata, K

    2009-01-01

    In order to get accurate measurements of air entrainment in a suction sump, we design some new simple bubble sensors, which can detect the existence of air bubbles inside a suction pipe with no disturbances by the sensors and with a fine spatial resolution. We force on an intermittency factor γ, that is, an occurrence-time ratio of the air entrainment, and compare the result by the present sensor with those by conventional two methods; namely, visual and auditory ones. As a result, we show the criteria which specify lower-accuracy conditions in the conventional methods. By the visual method, the accuracy of the γ becomes low, when γ is less than 0.05. By the auditory method, the accuracy of γ becomes low, when the submergence depth S of the suction pipe is close to the critical one S c .

  2. First observation of the decay Bs0-->Ds-Ds+ and measurement of its branching ratio.

    Science.gov (United States)

    Aaltonen, T; Adelman, J; Akimoto, T; Albrow, M G; Alvarez González, B; Amerio, S; Amidei, D; Anastassov, A; Annovi, A; Antos, J; Aoki, M; Apollinari, G; Apresyan, A; Arisawa, T; Artikov, A; Ashmanskas, W; Attal, A; Aurisano, A; Azfar, F; Azzi-Bacchetta, P; Azzurri, P; Bacchetta, N; Badgett, W; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Baroiant, S; Bartsch, V; Bauer, G; Beauchemin, P-H; Bedeschi, F; Bednar, P; Behari, S; Bellettini, G; Bellinger, J; Belloni, A; Benjamin, D; Beretvas, A; Beringer, J; Berry, T; Bhatti, A; Binkley, M; Bisello, D; Bizjak, I; Blair, R E; Blocker, C; Blumenfeld, B; Bocci, A; Bodek, A; Boisvert, V; Bolla, G; Bolshov, A; Bortoletto, D; Boudreau, J; Boveia, A; Brau, B; Bridgeman, A; Brigliadori, L; Bromberg, C; Brubaker, E; Budagov, J; Budd, H S; Budd, S; Burkett, K; Busetto, G; Bussey, P; Buzatu, A; Byrum, K L; Cabrera, S; Campanelli, M; Campbell, M; Canelli, F; Canepa, A; Carlsmith, D; Carosi, R; Carrillo, S; Carron, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chang, S H; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, K; Chokheli, D; Chou, J P; Choudalakis, G; Chuang, S H; Chung, K; Chung, W H; Chung, Y S; Ciobanu, C I; Ciocci, M A; Clark, A; Clark, D; Compostella, G; Convery, M E; Conway, J; Cooper, B; Copic, K; Cordelli, M; Cortiana, G; Crescioli, F; Cuenca Almenar, C; Cuevas, J; Culbertson, R; Cully, J C; Dagenhart, D; Datta, M; Davies, T; de Barbaro, P; De Cecco, S; Deisher, A; De Lentdecker, G; De Lorenzo, G; Dell'Orso, M; Demortier, L; Deng, J; Deninno, M; De Pedis, D; Derwent, P F; Di Giovanni, G P; Dionisi, C; Di Ruzza, B; Dittmann, J R; D'Onofrio, M; Donati, S; Dong, P; Donini, J; Dorigo, T; Dube, S; Efron, J; Erbacher, R; Errede, D; Errede, S; Eusebi, R; Fang, H C; Farrington, S; Fedorko, W T; Feild, R G; Feindt, M; Fernandez, J P; Ferrazza, C; Field, R; Flanagan, G; Forrest, R; Forrester, S; Franklin, M; Freeman, J C; Furic, I; Gallinaro, M; Galyardt, J; Garberson, F; Garcia, J E; Garfinkel, A F; Gerberich, H; Gerdes, D; Giagu, S; Giakoumopolou, V; Giannetti, P; Gibson, K; Gimmell, J L; Ginsburg, C M; Giokaris, N; Giordani, M; Giromini, P; Giunta, M; Glagolev, V; Glenzinski, D; Gold, M; Goldschmidt, N; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Goulianos, K; Gresele, A; Grinstein, S; Grosso-Pilcher, C; Grundler, U; Guimaraes da Costa, J; Gunay-Unalan, Z; Haber, C; Hahn, K; Hahn, S R; Halkiadakis, E; Hamilton, A; Han, B-Y; Han, J Y; Handler, R; Happacher, F; Hara, K; Hare, D; Hare, M; Harper, S; Harr, R F; Harris, R M; Hartz, M; Hatakeyama, K; Hauser, J; Hays, C; Heck, M; Heijboer, A; Heinemann, B; Heinrich, J; Henderson, C; Herndon, M; Heuser, J; Hewamanage, S; Hidas, D; Hill, C S; Hirschbuehl, D; Hocker, A; Hou, S; Houlden, M; Hsu, S-C; Huffman, B T; Hughes, R E; Husemann, U; Huston, J; Incandela, J; Introzzi, G; Iori, M; Ivanov, A; Iyutin, B; James, E; Jayatilaka, B; Jeans, D; Jeon, E J; Jindariani, S; Johnson, W; Jones, M; Joo, K K; Jun, S Y; Jung, J E; Junk, T R; Kamon, T; Kar, D; Karchin, P E; Kato, Y; Kephart, R; Kerzel, U; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, J E; Kim, M J; Kim, S B; Kim, S H; Kim, Y K; Kimura, N; Kirsch, L; Klimenko, S; Klute, M; Knuteson, B; Ko, B R; Koay, S A; Kondo, K; Kong, D J; Konigsberg, J; Korytov, A; Kotwal, A V; Kraus, J; Kreps, M; Kroll, J; Krumnack, N; Kruse, M; Krutelyov, V; Kubo, T; Kuhlmann, S E; Kuhr, T; Kulkarni, N P; Kusakabe, Y; Kwang, S; Laasanen, A T; Lai, S; Lami, S; Lammel, S; Lancaster, M; Lander, R L; Lannon, K; Lath, A; Latino, G; Lazzizzera, I; Lecompte, T; Lee, J; Lee, J; Lee, Y J; Lee, S W; Lefèvre, R; Leonardo, N; Leone, S; Levy, S; Lewis, J D; Lin, C; Lin, C S; Linacre, J; Lindgren, M; Lipeles, E; Lister, A; Litvintsev, D O; Liu, T; Lockyer, N S; Loginov, A; Loreti, M; Lovas, L; Lu, R-S; Lucchesi, D; Lueck, J; Luci, C; Lujan, P; Lukens, P; Lungu, G; Lyons, L; Lys, J; Lysak, R; Lytken, E; Mack, P; Macqueen, D; Madrak, R; Maeshima, K; Makhoul, K; Maki, T; Maksimovic, P; Malde, S; Malik, S; Manca, G; Manousakis, A; Margaroli, F; Marino, C; Marino, C P; Martin, A; Martin, M; Martin, V; Martínez, M; Martínez-Ballarín, R; Maruyama, T; Mastrandrea, P; Masubuchi, T; Mattson, M E; Mazzanti, P; McFarland, K S; McIntyre, P; McNulty, R; Mehta, A; Mehtala, P; Menzemer, S; Menzione, A; Merkel, P; Mesropian, C; Messina, A; Miao, T; Miladinovic, N; Miles, J; Miller, R; Mills, C; Milnik, M; Mitra, A; Mitselmakher, G; Miyake, H; Moed, S; Moggi, N; Moon, C S; Moore, R; Morello, M; Movilla Fernandez, P; Mülmenstädt, J; Mukherjee, A; Muller, Th; Mumford, R; Murat, P; Mussini, M; Nachtman, J; Nagai, Y; Nagano, A; Naganoma, J; Nakamura, K; Nakano, I; Napier, A; Necula, V; Neu, C; Neubauer, M S; Nielsen, J; Nodulman, L; Norman, M; Norniella, O; Nurse, E; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Oldeman, R; Orava, R; Osterberg, K; Pagan Griso, S; Pagliarone, C; Palencia, E; Papadimitriou, V; Papaikonomou, A; Paramonov, A A; Parks, B; Pashapour, S; Patrick, J; Pauletta, G; Paulini, M; Paus, C; Pellett, D E; Penzo, A; Phillips, T J; Piacentino, G; Piedra, J; Pinera, L; Pitts, K; Plager, C; Pondrom, L; Portell, X; Poukhov, O; Pounder, N; Prakoshyn, F; Pronko, A; Proudfoot, J; Ptohos, F; Punzi, G; Pursley, J; Rademacker, J; Rahaman, A; Ramakrishnan, V; Ranjan, N; Redondo, I; Reisert, B; Rekovic, V; Renton, P; Rescigno, M; Richter, S; Rimondi, F; Ristori, L; Robson, A; Rodrigo, T; Rogers, E; Rolli, S; Roser, R; Rossi, M; Rossin, R; Roy, P; Ruiz, A; Russ, J; Rusu, V; Saarikko, H; Safonov, A; Sakumoto, W K; Salamanna, G; Saltó, O; Santi, L; Sarkar, S; Sartori, L; Sato, K; Savoy-Navarro, A; Scheidle, T; Schlabach, P; Schmidt, E E; Schmidt, M A; Schmidt, M P; Schmitt, M; Schwarz, T; Scodellaro, L; Scott, A L; Scribano, A; Scuri, F; Sedov, A; Seidel, S; Seiya, Y; Semenov, A; Sexton-Kennedy, L; Sfyria, A; Shalhout, S Z; Shapiro, M D; Shears, T; Shepard, P F; Sherman, D; Shimojima, M; Shochet, M; Shon, Y; Shreyber, I; Sidoti, A; Sinervo, P; Sisakyan, A; Slaughter, A J; Slaunwhite, J; Sliwa, K; Smith, J R; Snider, F D; Snihur, R; Soderberg, M; Soha, A; Somalwar, S; Sorin, V; Spalding, J; Spinella, F; Spreitzer, T; Squillacioti, P; Stanitzki, M; St Denis, R; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Stuart, D; Suh, J S; Sukhanov, A; Sun, H; Suslov, I; Suzuki, T; Taffard, A; Takashima, R; Takeuchi, Y; Tanaka, R; Tecchio, M; Teng, P K; Terashi, K; Thom, J; Thompson, A S; Thompson, G A; Thomson, E; Tipton, P; Tiwari, V; Tkaczyk, S; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Tourneur, S; Trischuk, W; Tu, Y; Turini, N; Ukegawa, F; Uozumi, S; Vallecorsa, S; van Remortel, N; Varganov, A; Vataga, E; Vázquez, F; Velev, G; Vellidis, C; Veszpremi, V; Vidal, M; Vidal, R; Vila, I; Vilar, R; Vine, T; Vogel, M; Volobouev, I; Volpi, G; Würthwein, F; Wagner, P; Wagner, R G; Wagner, R L; Wagner-Kuhr, J; Wagner, W; Wakisaka, T; Wallny, R; Wang, S M; Warburton, A; Waters, D; Weinberger, M; Wester, W C; Whitehouse, B; Whiteson, D; Wicklund, A B; Wicklund, E; Williams, G; Williams, H H; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, C; Wright, T; Wu, X; Wynne, S M; Yagil, A; Yamamoto, K; Yamaoka, J; Yamashita, T; Yang, C; Yang, U K; Yang, Y C; Yao, W M; Yeh, G P; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Yu, S S; Yun, J C; Zanello, L; Zanetti, A; Zaw, I; Zhang, X; Zheng, Y; Zucchelli, S

    2008-01-18

    We report the observation of the exclusive decay Bs0-->Ds-Ds+ at the 7.5 standard deviation level using 355 pb(-1) of data collected by the CDF II detector in pp collisions at sqrt[s]=1.96 TeV at the Fermilab Tevatron. We measure the relative branching ratio B(Bs0-->Ds-Ds+)/B(B0-->D-Ds+)=1.44(-0.44)(+0.48). Using the world average value for B(B0-->D-Ds+), we find B(Bs0-->Ds-Ds+)=(9.4(-4.2)(+4.4))x10(-3). This provides a lower bound DeltaGammasCP/Gammas>or=2B(Bs0-->Ds-Ds+)>1.2x10(-2) at 95% C.L.

  3. A new strain gage method for measuring the contractile strain ratio of Zircaloy tubing

    International Nuclear Information System (INIS)

    Hwang, S.K.; Sabol, G.P.

    1988-01-01

    An improved strain gage method for determining the contractile strain ratio (CSR) of Zircaloy tubing was developed. The new method consists of a number of load-unload cyclings at approximately 0.2% plastic strain interval. With this method the CSR of Zircaloy-4 tubing could be determined accurately because it was possible to separate the plastic strains from the elastic strain involvement. The CSR values determined by use of the new method were in good agreement with those calculated from conventional post-test manual measurements. The CSR of the tubing was found to decrease with the amount of deformation during testing because of uneven plastic flow in the gage section. A new technique of inscribing gage marks by use of a YAG laser is discussed. (orig.)

  4. Measurement of the branching ratio for η→π0γγ decay

    International Nuclear Information System (INIS)

    Prakhov, S.; Nefkens, B.M.K.; Clajus, M.; Marusic, A.; McDonald, S.; Phaisangittisakul, N.; Price, J.W.; Starostin, A.; Tippens, W.B.; Allgower, C.E.; Spinka, H.; Bekrenev, V.; Koulbardis, A.; Kozlenko, N.; Kruglov, S.; Lopatin, I.; Briscoe, W.J.; Shafi, A.; Comfort, J.R.; Craig, K.

    2005-01-01

    The branching ratio (BR) for the rare decay η→π 0 γγ was measured with the Crystal Ball multiphoton spectrometer. The result, BR(η→π 0 γγ)=(3.5±0.7 stat ±0.6 syst )x10 -4 , is in agreement with calculations of chiral perturbation theory to third order. We have used a sample of 28 million η mesons produced at the BNL Alternating Gradient Synchrotron using the π - p→ηn reaction close to threshold. We detail the intricate extraction of the signal, which has about 1.6 thousand η→π 0 γγ events, from the overwhelming background of η→3π 0 decays and from the π - p→π 0 π 0 n reaction

  5. Shape coexistence from lifetime and branching-ratio measurements in 68,70Ni

    Directory of Open Access Journals (Sweden)

    B.P. Crider

    2016-12-01

    Full Text Available Shape coexistence near closed-shell nuclei, whereby states associated with deformed shapes appear at relatively low excitation energy alongside spherical ones, is indicative of the rapid change in structure that can occur with the addition or removal of a few protons or neutrons. Near 68Ni (Z=28, N=40, the identification of shape coexistence hinges on hitherto undetermined transition rates to and from low-energy 0+ states. In 68,70Ni, new lifetimes and branching ratios have been measured. These data enable quantitative descriptions of the 0+ states through the deduced transition rates and serve as sensitive probes for characterizing their nuclear wave functions. The results are compared to, and consistent with, large-scale shell-model calculations which predict shape coexistence. With the firm identification of this phenomenon near 68Ni, shape coexistence is now observed in all currently accessible regions of the nuclear chart with closed proton shells and mid-shell neutrons.

  6. Measurement of the Branching Ratio Lambda_c+ -> p pi+ pi-

    Energy Technology Data Exchange (ETDEWEB)

    Lopez-Hinojosa, Guillermo; /San Luis Potosi U.

    2008-03-01

    The confirmation of the Cabibbo-suppressed charm baryon decay mode {Lambda}{sub c}{sup +} {yields} p{pi}{sup +}{pi}{sup -} is reported. All data analyzed are from SELEX, a fixed target experiment at Fermilab that took data during 1996 and 1997, mainly with a 600 GeV/c {Sigma}{sup -} beam. The branching ratio of the Cabibbo-suppressed decay mode {Lambda}{sub c}{sup +} {yields} p{pi}{sup +}{pi}{sup -} relative to the Cabibbo-favored mode {Lambda}{sub c}{sup +} {yields} pK{sup -}{pi}{sup +} is measured to be: {Gamma}({Lambda}{sub c}{sup +} {yields} p{pi}{sup +}{pi}{sup -})/{Gamma}({Lambda}{sub c}{sup +} {yields} pK{sup -}{pi}{sup +}) = 0.103 {+-} 0.022.

  7. Accuracy of signal-to-noise ratio measurement method for magnetic resonance images

    International Nuclear Information System (INIS)

    Ogura, Akio; Miyai, Akira; Maeda, Fumie; Fukutake, Hiroyuki; Kikumoto, Rikiya

    2003-01-01

    The signal-to-noise ratio (SNR) of a magnetic resonance image is a common measure of imager performance. However, evaluations for the calculation of the SNR use various methods. A problem with measuring SNR is caused by the distortion of noise statistics in commonly used magnitude images. In this study, measurement accuracy was compared among four methods of evaluating SNR according to the size and position of regions of interest (ROIs). The results indicated that the method that used the difference between two images showed the best agreement with the theoretical value. In the method that used a single image, the SNR calculated by using a small size of ROI showed better agreement with the theoretical value because of noise bias and image artifacts. However, in the method that used the difference between two images, a large size of ROI was better in reducing statistical errors. In the same way, the methods that used air noise and air signal were better when applied to a large ROI. In addition, the image subtraction process used to calculate pixel-by-pixel differences in images may reach zero on a minus pixel value when using an image processor with the MRI system and apparatuses associated with it. A revised equation is presented for this case. It is important to understand the characteristics of each method and to choose a suitable method carefully according to the purpose of the study. (author)

  8. Energy intensity ratios as net energy measures of United States energy production and expenditures

    International Nuclear Information System (INIS)

    King, C W

    2010-01-01

    In this letter I compare two measures of energy quality, energy return on energy invested (EROI) and energy intensity ratio (EIR) for the fossil fuel consumption and production of the United States. All other characteristics being equal, a fuel or energy system with a higher EROI or EIR is of better quality because more energy is provided to society. I define and calculate the EIR for oil, natural gas, coal, and electricity as measures of the energy intensity (units of energy divided by money) of the energy resource relative to the energy intensity of the overall economy. EIR measures based upon various unit prices for energy (e.g. $/Btu of a barrel of oil) as well as total expenditures on energy supplies (e.g. total dollars spent on petroleum) indicate net energy at different points in the supply chain of the overall energy system. The results indicate that EIR is an easily calculated and effective proxy for EROI for US oil, gas, coal, and electricity. The EIR correlates well with previous EROI calculations, but adds additional information on energy resource quality within the supply chain. Furthermore, the EIR and EROI of oil and gas as well as coal were all in decline for two time periods within the last 40 years, and both time periods preceded economic recessions.

  9. O/M ratio measurement in pure and mixed oxide fuels - where are we now?

    Energy Technology Data Exchange (ETDEWEB)

    Rubin, J.; Chidester, K.; Thompson, M. [Los Alamos National Lab., NM (United States)

    2001-07-01

    The scale-down in the US and Russian nuclear weapons stockpiles has produced a surplus of weapons grade plutonium and highly enriched uranium. The incorporation into mixed-oxide fuel (MOX) is one of the currently favored routes for surplus weapons-grade plutonium. The use of MOX as a nuclear reactor fuel is well established, particularly in Europe and Japan but not in the US. The primary purpose of this investigation was to evaluate existing analytical techniques for their applicability to O/M (oxygen-to-metal ratio) measurements of MOX derived from excess weapons plutonium. The second objective of this investigation was to bring up-to-date the literature on O/M measurement methods, which has not been undertaken in over 20 years. There are several classification schemes that can be used to organize O/M measurement methods. The most popular schemes are based on (a) whether the analysis is performed in solution (wet chemical) or on solid material (dry), and (b) whether the concentration of major constituents are analyzed directly (direct) or are inferred (indirect). Solid state coulometric titration is currently used extensively in studies of phase equilibria, defect chemistry, thermochemical measurement of oxides, including ferrites. Regardless of which indirect method is used (solid state coulometric titration or thermogravimetry), a primary, direct method will also be required for the establishment of the MO{sub 2} reference state, determination of method bias, and periodic calibration. It was recommended that the following direct method be adapted for this purpose: oxygen measurement by inert gas fusion/carbon reduction, and total U, Pu by controlled potential coulometry. In a table are listed the experimental values of accuracy for about 30 O/M methods. (A.C.)

  10. Amphibious hearing in spotted seals (Phoca largha): underwater audiograms, aerial audiograms and critical ratio measurements.

    Science.gov (United States)

    Sills, Jillian M; Southall, Brandon L; Reichmuth, Colleen

    2014-03-01

    Spotted seals (Phoca largha) inhabit Arctic regions that are facing both rapid climate change and increasing industrialization. While little is known about their sensory capabilities, available knowledge suggests that spotted seals and other ice seals use sound to obtain information from the surrounding environment. To quantitatively assess their auditory capabilities, the hearing of two young spotted seals was tested using a psychophysical paradigm. Absolute detection thresholds for tonal sounds were measured in air and under water over the frequency range of hearing, and critical ratios were determined using octave-band masking noise in both media. The behavioral audiograms show a range of best sensitivity spanning four octaves in air, from approximately 0.6 to 11 kHz. The range of sensitive hearing extends across seven octaves in water, with lowest thresholds between 0.3 and 56 kHz. Critical ratio measurements were similar in air and water and increased monotonically from 12 dB at 0.1 kHz to 30 dB at 25.6 kHz, indicating that the auditory systems of these seals are quite efficient at extracting signals from background noise. This study demonstrates that spotted seals possess sound reception capabilities different from those previously described for ice seals, and more similar to those reported for harbor seals (Phoca vitulina). The results are consistent with the amphibious lifestyle of these seals and their apparent reliance on sound. The hearing data reported herein are the first available for spotted seals and can inform best management practices for this vulnerable species in a changing Arctic.

  11. Measurement of 233U/234U ratios in contaminated groundwater using alpha spectrometry

    International Nuclear Information System (INIS)

    Harrison, Jennifer J.; Payne, Timothy E.; Wilsher, Kerry L.; Thiruvoth, Sangeeth; Child, David P.; Johansen, Mathew P.; Hotchkis, Michael A.C.

    2016-01-01

    The uranium isotope 233 U is not usually observed in alpha spectra from environmental samples due to its low natural and fallout abundance. It may be present in samples from sites in the vicinity of nuclear operations such as reactors or fuel reprocessing facilities, radioactive waste disposal sites or sites affected by clandestine nuclear operations. On an alpha spectrum, the two most abundant alpha emissions of 233 U (4.784 MeV, 13.2%; and 4.824 MeV, 84.3%) will overlap with the 234 U doublet peak (4.722 MeV, 28.4%; and 4.775 MeV, 71.4%), if present, resulting in a combined 233+234 U multiplet. A technique for quantifying both 233 U and 234 U from alpha spectra was investigated. A series of groundwater samples were measured both by accelerator mass spectrometry (AMS) to determine 233 U/ 234 U atom and activity ratios and by alpha spectrometry in order to establish a reliable 233 U estimation technique using alpha spectra. The Genie™ 2000 Alpha Analysis and Interactive Peak Fitting (IPF) software packages were used and it was found that IPF with identification of three peaks ( 234 U minor, combined 234 U major and 233 U minor, and 233 U major) followed by interference correction on the combined peak and a weighted average activity calculation gave satisfactory agreement with the AMS data across the 233 U/ 234 U activity ratio range (0.1–20) and 233 U activity range (2–300 mBq) investigated. Correlation between the AMS 233 U and alpha spectrometry 233 U was r 2  = 0.996 (n = 10). - Highlights: • Describes a technique for deconvoluting the combined 233 U and 234 U multiplet in alpha spectra. • Enables 233 U and 234 U activities and 233 U/ 234 U ratios to be quantified without requiring additional analysis and measurement. • Applicable to an environmental matrix (groundwater) using standard alpha spectrometry counting equipment, operation and set-up.

  12. Improved environmental and forensics measurements using multiple ion counters in isotope ratio mass spectrometry

    International Nuclear Information System (INIS)

    Goldberg, S.A.; Richter, S.; Schwieters, H.

    2002-01-01

    Full text: A new detector system designed for isotope ratio mass spectrometers provides improved precision on measurements of samples with very low amounts ( -11 grams) of analyte. An array of continuous dynode electron multipliers has been installed on a new ThermoFinnigan MAT Triton thermal ionization mass spectrometer acquired by the New Brunswick Laboratory. These ion counters are modifications of miniaturized, commercially-available continuous dynode electron multipliers. They can be readily installed to replace individual Faraday cups in a multi-detector mass spectrometer or bundled together and located along the detector plane with a set of Faraday cups. On the New Brunswick Laboratory mass spectrometer, nine Faraday cups, one conventional discrete dynode electron multiplier, and seven miniaturized ion counters were installed. Six of the small ion counters were bundled together and positioned on the high mass side of the Low 4 Faraday cup. One additional ion counter was positioned on the low mass side of the Low 4 Faraday cup. This arrangement allows for the simultaneous measurement of all uranium (including 233 U) or plutonium (including 244 Pu) isotopes, and allows for the measurement of larger 238 U intensities on the Faraday cup if needed. Unit mass spacing of U, Pu, or other actinides is readily achieved by the use of a mass dispersion zoom lens. The advantage of multiple ion counting is the simultaneous collection of isotopes. It overcomes many of the problems such as transient signal variation in sample emission and ionization. For a given sample, multiple ion counting generates a greater number of counts for each isotope relative to single detector ion counting and provides improved counting statistics by a factor of two or more. Initial tests indicate that the multiple ion counters exhibit high counting efficiency, a dark noise of less than 10 counts per minute and typically less than 1 count per minute, and show linear response characteristics over

  13. Cross-Language Measurement Equivalence of the Center for Epidemiologic Studies Depression (CES-D) Scale in Systemic Sclerosis: A Comparison of Canadian and Dutch Patients

    Science.gov (United States)

    Kwakkenbos, Linda; Arthurs, Erin; van den Hoogen, Frank H. J.; Hudson, Marie; van Lankveld, Wim G. J. M.; Baron, Murray; van den Ende, Cornelia H. M.; Thombs, Brett D.

    2013-01-01

    Objectives Increasingly, medical research involves patients who complete outcomes in different languages. This occurs in countries with more than one common language, such as Canada (French/English) or the United States (Spanish/English), as well as in international multi-centre collaborations, which are utilized frequently in rare diseases such as systemic sclerosis (SSc). In order to pool or compare outcomes, instruments should be measurement equivalent (invariant) across cultural or linguistic groups. This study provides an example of how to assess cross-language measurement equivalence by comparing the Center for Epidemiologic Studies Depression (CES-D) scale between English-speaking Canadian and Dutch SSc patients. Methods The CES-D was completed by 922 English-speaking Canadian and 213 Dutch SSc patients. Confirmatory factor analysis (CFA) was used to assess the factor structure in both samples. The Multiple-Indicator Multiple-Cause (MIMIC) model was utilized to assess the amount of differential item functioning (DIF). Results A two-factor model (positive and negative affect) showed excellent fit in both samples. Statistically significant, but small-magnitude, DIF was found for 3 of 20 items on the CES-D. The English-speaking Canadian sample endorsed more feeling-related symptoms, whereas the Dutch sample endorsed more somatic/retarded activity symptoms. The overall estimate in depression scores between English and Dutch was not influenced substantively by DIF. Conclusions CES-D scores from English-speaking Canadian and Dutch SSc patients can be compared and pooled without concern that measurement differences may substantively influence results. The importance of assessing cross-language measurement equivalence in rheumatology studies prior to pooling outcomes obtained in different languages should be emphasized. PMID:23326538

  14. Equivalence of a Measurement Model of Cognitive Abilities in U.S. Standardization and Australian Neuroscience Samples

    Science.gov (United States)

    Bowden, Stephen C.; Weiss, Lawrence G.; Holdnack, James A.; Bardenhagen, Fiona J.; Cook, Mark J.

    2008-01-01

    A psychological measurement model provides an explicit definition of (a) the theoretical and (b) the numerical relationships between observed scores and the latent variables that underlie the observed scores. Examination of the metric invariance of a measurement model involves testing the hypothesis that all components of the model relating…

  15. A dual tracer ratio method for comparative emission measurements in an experimental dairy housing

    Science.gov (United States)

    Mohn, Joachim; Zeyer, Kerstin; Keck, Margret; Keller, Markus; Zähner, Michael; Poteko, Jernej; Emmenegger, Lukas; Schrade, Sabine

    2018-04-01

    Agriculture, and in particular dairy farming, is an important source of ammonia (NH3) and non-carbon dioxide greenhouse gas (GHG) emissions. This calls for the development and quantification of effective mitigation strategies. Our study presents the implementation of a dual tracer ratio method in a novel experimental dairy housing with two identical, but spatially separated housing areas. Modular design and flexible floor elements allow the assessment of structural, process engineering and organisational abatement measures at practical scale. Thereby, the emission reduction potential of specific abatement measures can be quantified in relation to a reference system. Emissions in the naturally ventilated housing are determined by continuous dosing of two artificial tracers (sulphur hexafluoride SF6, trifluoromethylsulphur pentafluoride SF5CF3) and their real-time detection in the ppt range with an optimized GC-ECD method. The two tracers are dosed into different experimental sections, which enables the independent assessment of both housing areas. Mass flow emissions of NH3 and GHGs are quantified by areal dosing of tracer gases and multipoint sampling as well as real-time analysis of both tracer and target gases. Validation experiments demonstrate that the technique is suitable for both areal and point emission sources and achieves an uncertainty of less than 10% for the mass emissions of NH3, methane (CH4) and carbon dioxide (CO2), which is superior to other currently available methods. Comparative emission measurements in this experimental dairy housing will provide reliable, currently unavailable information on emissions for Swiss dairy farming and demonstrate the reduction potential of mitigation measures for NH3, GHGs and potentially other pollutants.

  16. Testing Measurement Invariance Using MIMIC: Likelihood Ratio Test with a Critical Value Adjustment

    Science.gov (United States)

    Kim, Eun Sook; Yoon, Myeongsun; Lee, Taehun

    2012-01-01

    Multiple-indicators multiple-causes (MIMIC) modeling is often used to test a latent group mean difference while assuming the equivalence of factor loadings and intercepts over groups. However, this study demonstrated that MIMIC was insensitive to the presence of factor loading noninvariance, which implies that factor loading invariance should be…

  17. Measuring the B± → [D0 → f] K± branching ratio

    International Nuclear Information System (INIS)

    Limosani, A.

    2000-01-01

    Full text: The poster will detail the endeavour to measure the branching ratio for the charged B meson decay to neutral D and charged K meson, where D decays to a non-CP eigenstate i.e. B± → [D 0 /D 0 → f] K ± . The specific mode 'f' will be the doubly Cabibbo suppressed decay D 0 → K + π - . This measurement coupled with auxiliary information about D decays can be used to determine angle Φ 3 of the Unitarity triangle2. This triangle represents one of the unitary relations of the CKM matrix. The elements that contribute to this relation are directly related to the phenomena of CP Violation in B decays. The degree of violation observed will provide a good test of the minimal standard model and the proposed extensions. The poster will show the results of simulation studies conducted with QQ98 event generator, GSIM Monte Carlo of the BELLE detector response, and my own analysis code written as a module in BASF (Belle user Analysis Simulation Framework). The BELLE experiment is currently running at the KEK-B factory in Tsukuba, Japan. These studies should place a lower limit on the number of charged B events, needed to observe the nominated decay with the BELLE detector

  18. Improvement of the tetrachloromercurate absorption technique for measuring low atmospheric SO2 mixing ratios

    Science.gov (United States)

    Jaeschke, W.; Beltz, N.; Haunold, W.; Krischke, U.

    1997-07-01

    During the Gas-Phase Sulfur Intercomparison Experiment (GASIE) in 1994 an analytical system for measuring sulfur dioxide mixing ratios at low parts per trillion (pptv) levels was employed. It is based on the absorption of SO2 on a tetrachloromercurate(II)-impregnated filter. The subsequent analysis uses a chemiluminescence reaction by treating the resulting disulfitomercurate(II) complex with an acidic cerium sulfate solution. An improved sampling device has been introduced that increases the maximum sampling volume from 200 L to 500 L. It is also possible to determine the blank value accurately for each sample. The absorption efficiency of the sampling system is 98.7±6.4% at a nominal flow rate of 10 L/min. The calculated (3σ) detection limit is 3±1 pptv SO2. The sample solution is stable for up to 30 days, which allows the samples to be safely stored or shipped before analysis. This permits the use of a sensitive, compact, and reliable sampling system in the field with subsequent analysis under optimal conditions in the laboratory. A continuous flow chemiluminescence (CFCL) analyzer for on-line measurements is also presented. The system is based on the same chemical principles as the described filter technique.

  19. Branching Ratios and Spectral Functions of $\\tau$ Decays final ALEPH measurements and physics implications

    CERN Document Server

    Schael, S.; Bruneliere, R.; De Bonis, I.; Decamp, D.; Goy, C.; Jezequel, S.; Lees, J.-P.; Martin, F.; Merle, E.; Minard, M.-N.; Pietrzyk, B.; Trocme, B.; Bravo, S.; Casado, M.P.; Chmeissani, M.; Crespo, J.M.; Fernandez, E.; Fernandez-Bosman, M.; Garrido, Ll.; Martinez, M.; Pacheco, A.; Ruiz, H.; Colaleo, A.; Creanza, D.; De Filippis, N.; de Palma, M.; Iaselli, G.; Maggi, G.; Maggi, M.; Nuzzo, S.; Ranieri, A.; Raso, G.; Ruggieri, F.; Selvaggi, G.; Silvestris, L.; Tempesta, P.; Tricomi, A.; Zito, G.; Huang, X.; Lin, J.; Ouyang, Q.; Wang, T.; Xie, Y.; Xu, R.; Xue, S.; Zhang, J.; Zhang, L.; Zhao, W.; Abbaneo, D.; Barklow, T.; Buchmuller, O.; Cattaneo, M.; Clerbaux, B.; Drevermann, H.; Forty, R.W.; Frank, M.; Gianotti, F.; Hansen, J.B.; Harvey, J.; Hutchcroft, D.E.; Janot, P.; Jost, B.; Kado, M.; Mato, P.; Moutoussi, A.; Ranjard, F.; Rolandi, L.; Schlatter, D.; Teubert, F.; Valassi, A.; Videau, I.; Badaud, F.; Dessagne, S.; Falvard, A.; Fayolle, D.; Gay, P.; Jousset, J.; Michel, B.; Monteil, S.; Pallin, D.; Pascolo, J.M.; Perret, P.; Hansen, J.D.; Hansen, J.R.; Hansen, P.H.; Kraan, A.C.; Nilsson, B.S.; Kyriakis, A.; Markou, C.; Simopoulou, E.; Vayaki, A.; Zachariadou, K.; Blondel, A.; Brient, J.-C.; Machefert, F.; Rouge, A.; Videau, H.; Ciulli, V.; Focardi, E.; Parrini, G.; Antonelli, A.; Antonelli, M.; Bencivenni, G.; Bossi, F.; Capon, G.; Cerutti, F.; Chiarella, V.; Laurelli, P.; Mannocchi, G.; Murtas, G.P.; Passalacqua, L.; Kennedy, J.; Lynch, J.G.; Negus, P.; O'Shea, V.; Thompson, A.S.; Wasserbaech, S.; Cavanaugh, R.; Dhamotharan, S.; Geweniger, C.; Hanke, P.; Hepp, V.; Kluge, E.E.; Putzer, A.; Stenzel, H.; Tittel, K.; Wunsch, M.; Phys., Kirchhoff Inst.; Beuselinck, R.; Cameron, W.; Davies, G.; Dornan, P.J.; Girone, M.; Marinelli, N.; Nowell, J.; Rutherford, S.A.; Sedgbeer, J.K.; Thompson, J.C.; White, R.; Ghete, V.M.; Girtler, P.; Kneringer, E.; Kuhn, D.; Rudolph, G.; Bouhova-Thacker, E.; Bowdery, C.K.; Clarke, D.P.; Ellis, G.; Finch, A.J.; Foster, F.; Hughes, G.; Jones, R.W.L.; Pearson, M.R.; Robertson, N.A.; Smizanska, M.; van der Aa, O.; Delaere, C.; Leibenguth, G.; Lemaitre, V.; Blumenschein, U.; Holldorfer, F.; Jakobs, K.; Kayser, F.; Muller, A.-S.; Renk, B.; Sander, H.-G.; Schmeling, S.; Wachsmuth, H.; Zeitnitz, C.; Ziegler, T.; Bonissent, A.; Coyle, P.; Curtil, C.; Ealet, A.; Fouchez, D.; Payre, P.; Tilquin, A.; Ragusa, F.; David, A.; Dietl, H.; Ganis, G.; Huttmann, K.; Lutjens, G.; Manner, W.; Moser, H.-G.; Settles, R.; Villegas, M.; Wolf, G.; Boucrot, J.; Callot, O.; Davier, M.; Duflot, L.; Grivaz, J.-F.; Heusse, Ph.; Hocker, Andreas; Jacholkowska, A.; Serin, L.; Veillet, J.-J.; Yuan, C.Z.; Zhang, Z.Q.; Azzurri, P.; Bagliesi, Giuseppe; Boccali, T.; Foa, L.; Giammanco, A.; Giassi, A.; Ligabue, F.; Messineo, A.; Palla, F.; Sanguinetti, G.; Sciaba, A.; Sguazzoni, G.; Spagnolo, P.; Tenchini, R.; Venturi, A.; Verdini, P.G.; Awunor, O.; Blair, G.A.; Cowan, G.; Garcia-Bellido, A.; Green, M.G.; Medcalf, T.; Misiejuk, A.; Strong, J.A.; Teixeira-Dias, P.; Clifft, R.W.; Edgecock, T.R.; Norton, P.R.; Tomalin, I.R.; Ward, J.J.; Bloch-Devaux, Brigitte; Boumediene, D.; Colas, P.; Fabbro, B.; Lancon, E.; Lemaire, M.-C.; Locci, E.; Perez, P.; Rander, J.; Tuchming, B.; Vallage, G.; Litke, A.M.; Taylor, G.; Booth, C.N.; Cartwright, S.; Combley, F.; Hodgson, P.N.; Lehto, M.; Thompson, L.F.; Bohrer, A.; Brandt, S.; Grupen, C.; Hess, J.; Ngac, A.; Prange, G.; Borean, C.; Giannini, G.; He, H.; Putz, J.; Rothberg, J.; Armstrong, S.R.; Berkelman, Karl; Cranmer, K.; Ferguson, D.P.S.; Gao, Y.; Gonzalez, S.; Hayes, O.J.; Hu, H.; Jin, S.; Kile, J.; McNamara, P.A., III; Nielsen, J.; Pan, Y.B.; von Wimmersperg-Toeller, J.H.; Wiedenmann, W.; Wu, J.; Wu, Sau Lan; Wu, X.; Zobernig, G.; Dissertori, G.

    2005-01-01

    The full LEP-1 data set collected with the ALEPH detector at the $Z$ pole during 1991-1995 is analysed in order to measure the $\\tau$ decay branching fractions. The analysis follows the global method used in the published study based on 1991-1993 data, but several improvements are introduced, especially concerning the treatment of photons and $\\pi^0$'s. Extensive systematic studies are performed, in order to match the large statistics of the data sample corresponding to over 300\\,000 measured and identified $\\tau$ decays. Branching fractions are obtained for the two leptonic channels and eleven hadronic channels defined by their respective numbers of charged particles and $\\pi^0$'s. Using previously published ALEPH results on final states with charged and neutral kaons, corrections are applied to the hadronic channels to derive branching ratios for exclusive final states without kaons. Thus the analyses of the full LEP-1 ALEPH data are combined to yield a complete description of $\\tau$ decays, encompassing 22...

  20. Shock tube measurements of the branching ratios of propene + OH -> products

    KAUST Repository

    Khaled, Fathi

    2014-07-25

    Absolute rate coefficients for the reaction of OH radical with propene (C3H6) and five deutrated isotopes, propene-1-d1 (CDHCHCH3), propene-1,1-d2 (CD2CHCH3), propene-2-d1 (CH2CDCH3), propene-3,3,3-d3 (CH2CHCD3), and propene-d6 (C3D6), were measured in a shock tube behind reflected shock conditions over the temperature range of 812 K – 1460 K and pressures near 1 atm. The reaction progress was followed by monitoring OH radical near 306.7 nm using UV laser absorption. The first experimental measurements for the branching ratio of the title reaction are reported and compared with theoretical calculations. The allylic H atom abstraction of propene by OH radicals was found to be the most dominant reaction pathway followed by propen-1-yl and propen-2-yl channels over the entire temperature range of this study which is in line with theoretical predictions. Arrhenius parameters for various site-specific rate coefficients are provided for kinetic modeling.

  1. Measurement of circumsolar ratio in high dust loading regions using a photographic method

    Science.gov (United States)

    Al-Ansary, Hany; Shafiq, Talha; Rizvi, Arslan; El-Leathy, Abdelrahman

    2017-06-01

    Performance of concentrating solar power (CSP) plants is highly affected by direct normal irradiance (DNI). However, it is also important to consider circumsolar radiation in any simulation of a CSP plant, especially in desert regions where dust loading in the atmosphere is expected. There are a number of methods to measure circumsolar radiation. However, most of them require expensive instrumentation. This work introduces a simple method to estimate circumsolar radiation. It involves taking high-resolution photographs of the sun and processing them using a computer code that identifies the sun's disk. The code then uses pixel intensities to obtain the solar intensity distribution across the sun's disk and in the aureole region. The solar intensity distribution is then used to obtain the circumsolar ratio (CSR) which represents the shape of the sun. To test this method, numerous photos of the sun were taken during the month of April and September 2016 at King Saud University in Riyadh, Saudi Arabia. Riyadh is a region that is well known for high dust-loading, especially during the summer. Two days of different atmospheric conditions were selected in September for comparative analysis. Results show that this method produces repeatable results, and that the CSR can increase significantly due to high dust loading and passing clouds. The CSR is found to be a strong function of DNI, ranging from about 4.5% at DNI values above 800 W/m2 and increasing to as much as 8.5% when DNI drops to about 400 W/m2, due to passing clouds. Furthermore, the results show that circumsolar ratio tends to be high in the early morning and late afternoon due to the high air mass, while its values tend to be lowest around solar noon when the air mass is lowest.

  2. ICP-MS with hexapole collision cell for isotope ratio measurements of Ca, Fe, and Se

    Energy Technology Data Exchange (ETDEWEB)

    Boulyga, S.F. [Radiation Physics and Chemistry Problems Inst., Minsk (Belarus); Becker, J.S. [Central Department for Analytical Chemistry, Research Centre Juelich (Germany)

    2001-07-01

    To avoid mass interferences on analyte ions caused by argon ions and argon molecular ions via reactions with collision gases, an rf hexapole filled with helium and hydrogen has been used in inductively coupled plasma mass spectrometry (ICP-MS), and its performance has been studied. Up to tenfold improvement in sensitivity was observed for heavy elements (m > 100 u), because of better ion transmission through the hexapole ion guide. A reduction of argon ions Ar{sup +} and the molecular ions of argon ArX{sup +} (X = O, Ar) by up to three orders of magnitude was achieved in a hexapole collision cell of an ICP-MS (''Platform ICP'', Micromass, Manchester, UK) as a result of gas-phase reactions with hydrogen when the hexapole bias (HB) was set to 0 V; at an HB of 1.6 V argon, and argon-based ions of masses 40 u, 56 u, and 80 u, were reduced by approximately four, two, and five orders of magnitude, respectively. The signal-to-noise ratio {sup 80}Se/ {sup 40}Ar{sub 2}{sup +} was improved by more than five orders of magnitude under optimized experimental conditions. Dependence of mass discrimination on collision-cell properties was studied in the mass range 10 u (boron) to 238 u (uranium). Isotopic analysis of the elements affected by mass-spectrometric interference, Ca, Fe, and Se, was performed using a Meinhard nebulizer and an ultrasonic nebulizer (USN). The measured isotope ratios were comparable with tabulated values from IUPAC. Precision of 0.26%, 0.19%, and 0.12%, respectively, and accuracy of 0.13% 0.25%, and 0.92%, respectively, was achieved for isotope ratios {sup 44}Ca/ {sup 40}Ca and {sup 56}Fe/{sup 57}Fe in 10 {mu}g L{sup -1} solution nebulized by means of a USN and for {sup 78}Se/{sup 80}Se in 100 {mu}g L{sup -1} solution nebulized by means of a Meinhard nebulizer. (orig.)

  3. arXiv Measurement of the ratio of the $B^0 \\to D^{*-} \\tau^+ \

    CERN Document Server

    Aaij, Roel; LHCb Collaboration; Adinolfi, Marco; Ajaltouni, Ziad; Akar, Simon; Albrecht, Johannes; Alessio, Federico; Alexander, Michael; Alfonso Albero, Alejandro; Ali, Suvayu; Alkhazov, Georgy; Alvarez Cartelle, Paula; Alves Jr, Antonio Augusto; Amato, Sandra; Amerio, Silvia; Amhis, Yasmine; An, Liupan; Anderlini, Lucio; Andreassi, Guido; Andreotti, Mirco; Andrews, Jason; Appleby, Robert; Archilli, Flavio; d'Argent, Philippe; Arnau Romeu, Joan; Artamonov, Alexander; Artuso, Marina; Aslanides, Elie; Auriemma, Giulio; Baalouch, Marouen; Babuschkin, Igor; Bachmann, Sebastian; Back, John; Badalov, Alexey; Baesso, Clarissa; Baker, Sophie; Balagura, Vladislav; Baldini, Wander; Baranov, Alexander; Barlow, Roger; Barschel, Colin; Barsuk, Sergey; Barter, William; Baryshnikov, Fedor; Batozskaya, Varvara; Battista, Vincenzo; Bay, Aurelio; Beaucourt, Leo; Beddow, John; Bedeschi, Franco; Bediaga, Ignacio; Beiter, Andrew; Bel, Lennaert; Beliy, Nikita; Bellee, Violaine; Belloli, Nicoletta; Belous, Konstantin; Belyaev, Ivan; Ben-Haim, Eli; Bencivenni, Giovanni; Benson, Sean; Beranek, Sarah; Berezhnoy, Alexander; Bernet, Roland; Berninghoff, Daniel; Bertholet, Emilie; Bertolin, Alessandro; Betancourt, Christopher; Betti, Federico; Bettler, Marc-Olivier; van Beuzekom, Martinus; Bezshyiko, Iaroslava; Bifani, Simone; Billoir, Pierre; Birnkraut, Alex; Bitadze, Alexander; Bizzeti, Andrea; Bjørn, Mikkel; Blake, Thomas; Blanc, Frederic; Blouw, Johan; Blusk, Steven; Bocci, Valerio; Boettcher, Thomas; Bondar, Alexander; Bondar, Nikolay; Bonivento, Walter; Bordyuzhin, Igor; Borgheresi, Alessio; Borghi, Silvia; Borisyak, Maxim; Borsato, Martino; Bossu, Francesco; Boubdir, Meriem; Bowcock, Themistocles; Bowen, Espen Eie; Bozzi, Concezio; Braun, Svende; Britton, Thomas; Brodzicka, Jolanta; Brundu, Davide; Buchanan, Emma; Burr, Christopher; Bursche, Albert; Buytaert, Jan; Byczynski, Wiktor; Cadeddu, Sandro; Cai, Hao; Calabrese, Roberto; Calladine, Ryan; Calvi, Marta; Calvo Gomez, Miriam; Camboni, Alessandro; Campana, Pierluigi; Campora Perez, Daniel Hugo; Capriotti, Lorenzo; Carbone, Angelo; Carboni, Giovanni; Cardinale, Roberta; Cardini, Alessandro; Carniti, Paolo; Carson, Laurence; Carvalho Akiba, Kazuyoshi; Casse, Gianluigi; Cassina, Lorenzo; Castillo Garcia, Lucia; Cattaneo, Marco; Cavallero, Giovanni; Cenci, Riccardo; Chamont, David; Chapman, Matthew George; Charles, Matthew; Charpentier, Philippe; Chatzikonstantinidis, Georgios; Chefdeville, Maximilien; Chen, Shanzhen; Cheung, Shu Faye; Chitic, Stefan-Gabriel; Chobanova, Veronika; Chrzaszcz, Marcin; Chubykin, Alexsei; Ciambrone, Paolo; Cid Vidal, Xabier; Ciezarek, Gregory; Clarke, Peter; Clemencic, Marco; Cliff, Harry; Closier, Joel; Coco, Victor; Cogan, Julien; Cogneras, Eric; Cogoni, Violetta; Cojocariu, Lucian; Collins, Paula; Colombo, Tommaso; Comerma-Montells, Albert; Contu, Andrea; Cook, Andrew; Coombs, George; Coquereau, Samuel; Corti, Gloria; Corvo, Marco; Costa Sobral, Cayo Mar; Couturier, Benjamin; Cowan, Greig; Craik, Daniel Charles; Crocombe, Andrew; Cruz Torres, Melissa Maria; Currie, Robert; D'Ambrosio, Carmelo; Da Cunha Marinho, Franciole; Dall'Occo, Elena; Dalseno, Jeremy; Davis, Adam; De Aguiar Francisco, Oscar; De Bruyn, Kristof; De Capua, Stefano; De Cian, Michel; De Miranda, Jussara; De Paula, Leandro; De Serio, Marilisa; De Simone, Patrizia; Dean, Cameron Thomas; Decamp, Daniel; Del Buono, Luigi; Dembinski, Hans Peter; Demmer, Moritz; Dendek, Adam; Derkach, Denis; Deschamps, Olivier; Dettori, Francesco; Dey, Biplab; Di Canto, Angelo; Di Nezza, Pasquale; Dijkstra, Hans; Dordei, Francesca; Dorigo, Mirco; Dosil Suárez, Alvaro; Douglas, Lauren; Dovbnya, Anatoliy; Dreimanis, Karlis; Dufour, Laurent; Dujany, Giulio; Dungs, Kevin; Durante, Paolo; Dzhelyadin, Rustem; Dziewiecki, Michal; Dziurda, Agnieszka; Dzyuba, Alexey; Déléage, Nicolas; Easo, Sajan; Ebert, Marcus; Egede, Ulrik; Egorychev, Victor; Eidelman, Semen; Eisenhardt, Stephan; Eitschberger, Ulrich; Ekelhof, Robert; Eklund, Lars; Ely, Scott; Esen, Sevda; Evans, Hannah Mary; Evans, Timothy; Falabella, Antonio; Farley, Nathanael; Farry, Stephen; Fay, Robert; Fazzini, Davide; Federici, Luca; Ferguson, Dianne; Fernandez, Gerard; Fernandez Declara, Placido; Fernandez Prieto, Antonio; Ferrari, Fabio; Ferreira Rodrigues, Fernando; Ferro-Luzzi, Massimiliano; Filippov, Sergey; Fini, Rosa Anna; Fiore, Marco; Fiorini, Massimiliano; Firlej, Miroslaw; Fitzpatrick, Conor; Fiutowski, Tomasz; Fleuret, Frederic; Fohl, Klaus; Fontana, Marianna; Fontanelli, Flavio; Forshaw, Dean Charles; Forty, Roger; Franco Lima, Vinicius; Frank, Markus; Frei, Christoph; Fu, Jinlin; Funk, Wolfgang; Furfaro, Emiliano; Färber, Christian; Gabriel, Emmy; Gallas Torreira, Abraham; Galli, Domenico; Gallorini, Stefano; Gambetta, Silvia; Gandelman, Miriam; Gandini, Paolo; Gao, Yuanning; Garcia Martin, Luis Miguel; García Pardiñas, Julián; Garra Tico, Jordi; Garrido, Lluis; Garsed, Philip John; Gascon, David; Gaspar, Clara; Gavardi, Laura; Gazzoni, Giulio; Gerick, David; Gersabeck, Evelina; Gersabeck, Marco; Gershon, Timothy; Ghez, Philippe; Gianì, Sebastiana; Gibson, Valerie; Girard, Olivier Göran; Giubega, Lavinia-Helena; Gizdov, Konstantin; Gligorov, Vladimir; Golubkov, Dmitry; Golutvin, Andrey; Gomes, Alvaro; Gorelov, Igor Vladimirovich; Gotti, Claudio; Govorkova, Ekaterina; Grabowski, Jascha Peter; Graciani Diaz, Ricardo; Granado Cardoso, Luis Alberto; Graugés, Eugeni; Graverini, Elena; Graziani, Giacomo; Grecu, Alexandru; Greim, Roman; Griffith, Peter; Grillo, Lucia; Gruber, Lukas; Gruberg Cazon, Barak Raimond; Grünberg, Oliver; Gushchin, Evgeny; Guz, Yury; Gys, Thierry; Göbel, Carla; Hadavizadeh, Thomas; Hadjivasiliou, Christos; Haefeli, Guido; Haen, Christophe; Haines, Susan; Hamilton, Brian; Han, Xiaoxue; Hancock, Thomas Henry; Hansmann-Menzemer, Stephanie; Harnew, Neville; Harnew, Samuel; Harrison, Jonathan; Hasse, Christoph; Hatch, Mark; He, Jibo; Hecker, Malte; Heinicke, Kevin; Heister, Arno; Hennessy, Karol; Henrard, Pierre; Henry, Louis; van Herwijnen, Eric; Heß, Miriam; Hicheur, Adlène; Hill, Donal; Hombach, Christoph; Hopchev, Plamen Hristov; Huard, Zachary; Hulsbergen, Wouter; Humair, Thibaud; Hushchyn, Mikhail; Hutchcroft, David; Ibis, Philipp; Idzik, Marek; Ilten, Philip; Jacobsson, Richard; Jalocha, Pawel; Jans, Eddy; Jawahery, Abolhassan; Jiang, Feng; John, Malcolm; Johnson, Daniel; Jones, Christopher; Joram, Christian; Jost, Beat; Jurik, Nathan; Kandybei, Sergii; Karacson, Matthias; Kariuki, James Mwangi; Karodia, Sarah; Kazeev, Nikita; Kecke, Matthieu; Kelsey, Matthew; Kenzie, Matthew; Ketel, Tjeerd; Khairullin, Egor; Khanji, Basem; Khurewathanakul, Chitsanu; Kirn, Thomas; Klaver, Suzanne; Klimaszewski, Konrad; Klimkovich, Tatsiana; Koliiev, Serhii; Kolpin, Michael; Komarov, Ilya; Kopecna, Renata; Koppenburg, Patrick; Kosmyntseva, Alena; Kotriakhova, Sofia; Kozeiha, Mohamad; Kravchuk, Leonid; Kreps, Michal; Krokovny, Pavel; Kruse, Florian; Krzemien, Wojciech; Kucewicz, Wojciech; Kucharczyk, Marcin; Kudryavtsev, Vasily; Kuonen, Axel Kevin; Kurek, Krzysztof; Kvaratskheliya, Tengiz; Lacarrere, Daniel; Lafferty, George; Lai, Adriano; Lanfranchi, Gaia; Langenbruch, Christoph; Latham, Thomas; Lazzeroni, Cristina; Le Gac, Renaud; van Leerdam, Jeroen; Leflat, Alexander; Lefrançois, Jacques; Lefèvre, Regis; Lemaitre, Florian; Lemos Cid, Edgar; Leroy, Olivier; Lesiak, Tadeusz; Leverington, Blake; Li, Pei-Rong; Li, Tenglin; Li, Yiming; Li, Zhuoming; Likhomanenko, Tatiana; Lindner, Rolf; Lionetto, Federica; Liu, Xuesong; Loh, David; Loi, Angelo; Longstaff, Iain; Lopes, Jose; Lucchesi, Donatella; Lucio Martinez, Miriam; Luo, Haofei; Lupato, Anna; Luppi, Eleonora; Lupton, Oliver; Lusiani, Alberto; Lyu, Xiao-Rui; Machefert, Frederic; Maciuc, Florin; Macko, Vladimir; Mackowiak, Patrick; Maddrell-Mander, Samuel; Maev, Oleg; Maguire, Kevin; Maisuzenko, Dmitrii; Majewski, Maciej Witold; Malde, Sneha; Malinin, Alexander; Maltsev, Timofei; Manca, Giulia; Mancinelli, Giampiero; Manning, Peter Michael; Marangotto, Daniele; Maratas, Jan; Marchand, Jean François; Marconi, Umberto; Marin Benito, Carla; Marinangeli, Matthieu; Marino, Pietro; Marks, Jörg; Martellotti, Giuseppe; Martin, Morgan; Martinelli, Maurizio; Martinez Santos, Diego; Martinez Vidal, Fernando; Martins Tostes, Danielle; Massacrier, Laure Marie; Massafferri, André; Matev, Rosen; Mathad, Abhijit; Mathe, Zoltan; Matteuzzi, Clara; Mauri, Andrea; Maurice, Emilie; Maurin, Brice; Mazurov, Alexander; McCann, Michael; McNab, Andrew; McNulty, Ronan; Mead, James Vincent; Meadows, Brian; Meaux, Cedric; Meier, Frank; Meinert, Nis; Melnychuk, Dmytro; Merk, Marcel; Merli, Andrea; Michielin, Emanuele; Milanes, Diego Alejandro; Millard, Edward James; Minard, Marie-Noelle; Minzoni, Luca; Mitzel, Dominik Stefan; Mogini, Andrea; Molina Rodriguez, Josue; Mombächer, Titus; Monroy, Igancio Alberto; Monteil, Stephane; Morandin, Mauro; Morello, Michael Joseph; Morgunova, Olga; Moron, Jakub; Morris, Adam Benjamin; Mountain, Raymond; Muheim, Franz; Mulder, Mick; Mussini, Manuel; Müller, Dominik; Müller, Janine; Müller, Katharina; Müller, Vanessa; Naik, Paras; Nakada, Tatsuya; Nandakumar, Raja; Nandi, Anita; Nasteva, Irina; Needham, Matthew; Neri, Nicola; Neubert, Sebastian; Neufeld, Niko; Neuner, Max; Nguyen, Thi Dung; Nguyen-Mau, Chung; Nieswand, Simon; Niet, Ramon; Nikitin, Nikolay; Nikodem, Thomas; Nogay, Alla; O'Hanlon, Daniel Patrick; Oblakowska-Mucha, Agnieszka; Obraztsov, Vladimir; Ogilvy, Stephen; Oldeman, Rudolf; Onderwater, Gerco; Ossowska, Anna; Otalora Goicochea, Juan Martin; Owen, Patrick; Oyanguren, Maria Aranzazu; Pais, Preema Rennee; Palano, Antimo; Palutan, Matteo; Papanestis, Antonios; Pappagallo, Marco; Pappalardo, Luciano; Parker, William; Parkes, Christopher; Passaleva, Giovanni; Pastore, Alessandra; Patel, Mitesh; Patrignani, Claudia; Pearce, Alex; Pellegrino, Antonio; Penso, Gianni; Pepe Altarelli, Monica; Perazzini, Stefano; Perret, Pascal; Pescatore, Luca; Petridis, Konstantinos; Petrolini, Alessandro; Petrov, Aleksandr; Petruzzo, Marco; Picatoste Olloqui, Eduardo; Pietrzyk, Boleslaw; Pikies, Malgorzata; Pinci, Davide; Pisani, Flavio; Pistone, Alessandro; Piucci, Alessio; Placinta, Vlad-Mihai; Playfer, Stephen; Plo Casasus, Maximo; Polci, Francesco; Poli Lener, Marco; Poluektov, Anton; Polyakov, Ivan; Polycarpo, Erica; Pomery, Gabriela Johanna; Ponce, Sebastien; Popov, Alexander; Popov, Dmitry; Poslavskii, Stanislav; Potterat, Cédric; Price, Eugenia; Prisciandaro, Jessica; Prouve, Claire; Pugatch, Valery; Puig Navarro, Albert; Pullen, Hannah Louise; Punzi, Giovanni; Qian, Wenbin; Quagliani, Renato; Quintana, Boris; Rachwal, Bartlomiej; Rademacker, Jonas; Rama, Matteo; Ramos Pernas, Miguel; Rangel, Murilo; Raniuk, Iurii; Ratnikov, Fedor; Raven, Gerhard; Ravonel Salzgeber, Melody; Reboud, Meril; Redi, Federico; Reichert, Stefanie; dos Reis, Alberto; Remon Alepuz, Clara; Renaudin, Victor; Ricciardi, Stefania; Richards, Sophie; Rihl, Mariana; Rinnert, Kurt; Rives Molina, Vicente; Robbe, Patrick; Rodrigues, Ana Barbara; Rodrigues, Eduardo; Rodriguez Lopez, Jairo Alexis; Rodriguez Perez, Pablo; Rogozhnikov, Alexey; Roiser, Stefan; Rollings, Alexandra Paige; Romanovskiy, Vladimir; Romero Vidal, Antonio; Ronayne, John William; Rotondo, Marcello; Rudolph, Matthew Scott; Ruf, Thomas; Ruiz Valls, Pablo; Ruiz Vidal, Joan; Saborido Silva, Juan Jose; Sadykhov, Elnur; Sagidova, Naylya; Saitta, Biagio; Salustino Guimaraes, Valdir; Sanchez Mayordomo, Carlos; Sanmartin Sedes, Brais; Santacesaria, Roberta; Santamarina Rios, Cibran; Santimaria, Marco; Santovetti, Emanuele; Sarpis, Gediminas; Sarti, Alessio; Satriano, Celestina; Satta, Alessia; Saunders, Daniel Martin; Savrina, Darya; Schael, Stefan; Schellenberg, Margarete; Schiller, Manuel; Schindler, Heinrich; Schlupp, Maximilian; Schmelling, Michael; Schmelzer, Timon; Schmidt, Burkhard; Schneider, Olivier; Schopper, Andreas; Schreiner, HF; Schubert, Konstantin; Schubiger, Maxime; Schune, Marie Helene; Schwemmer, Rainer; Sciascia, Barbara; Sciubba, Adalberto; Semennikov, Alexander; Sergi, Antonino; Serra, Nicola; Serrano, Justine; Sestini, Lorenzo; Seyfert, Paul; Shapkin, Mikhail; Shapoval, Illya; Shcheglov, Yury; Shears, Tara; Shekhtman, Lev; Shevchenko, Vladimir; Siddi, Benedetto Gianluca; Silva Coutinho, Rafael; Silva de Oliveira, Luiz Gustavo; Simi, Gabriele; Simone, Saverio; Sirendi, Marek; Skidmore, Nicola; Skwarnicki, Tomasz; Smith, Eluned; Smith, Iwan Thomas; Smith, Jackson; Smith, Mark; Soares Lavra, Lais; Sokoloff, Michael; Soler, Paul; Souza De Paula, Bruno; Spaan, Bernhard; Spradlin, Patrick; Sridharan, Srikanth; Stagni, Federico; Stahl, Marian; Stahl, Sascha; Stefko, Pavol; Stefkova, Slavomira; Steinkamp, Olaf; Stemmle, Simon; Stenyakin, Oleg; Stepanova, Margarita; Stevens, Holger; Stone, Sheldon; Storaci, Barbara; Stracka, Simone; Stramaglia, Maria Elena; Straticiuc, Mihai; Straumann, Ulrich; Sun, Liang; Sutcliffe, William; Swientek, Krzysztof; Syropoulos, Vasileios; Szczekowski, Marek; Szumlak, Tomasz; Szymanski, Maciej Pawel; T'Jampens, Stephane; Tayduganov, Andrey; Tekampe, Tobias; Tellarini, Giulia; Teubert, Frederic; Thomas, Eric; van Tilburg, Jeroen; Tilley, Matthew James; Tisserand, Vincent; Tobin, Mark; Tolk, Siim; Tomassetti, Luca; Tonelli, Diego; Toriello, Francis; Tourinho Jadallah Aoude, Rafael; Tournefier, Edwige; Traill, Murdo; Tran, Minh Tâm; Tresch, Marco; Trisovic, Ana; Tsaregorodtsev, Andrei; Tsopelas, Panagiotis; Tully, Alison; Tuning, Niels; Ukleja, Artur; Ustyuzhanin, Andrey; Uwer, Ulrich; Vacca, Claudia; Vagner, Alexander; Vagnoni, Vincenzo; Valassi, Andrea; Valat, Sebastien; Valenti, Giovanni; Vazquez Gomez, Ricardo; Vazquez Regueiro, Pablo; Vecchi, Stefania; van Veghel, Maarten; Velthuis, Jaap; Veltri, Michele; Veneziano, Giovanni; Venkateswaran, Aravindhan; Verlage, Tobias Anton; Vernet, Maxime; Vesterinen, Mika; Viana Barbosa, Joao Vitor; Viaud, Benoit; Vieira, Daniel; Vieites Diaz, Maria; Viemann, Harald; Vilasis-Cardona, Xavier; Vitti, Marcela; Volkov, Vladimir; Vollhardt, Achim; Voneki, Balazs; Vorobyev, Alexey; Vorobyev, Vitaly; Voß, Christian; de Vries, Jacco; Vázquez Sierra, Carlos; Waldi, Roland; Wallace, Charlotte; Wallace, Ronan; Walsh, John; Wang, Jianchun; Ward, David; Wark, Heather Mckenzie; Watson, Nigel; Websdale, David; Weiden, Andreas; Whitehead, Mark; Wicht, Jean; Wilkinson, Guy; Wilkinson, Michael; Williams, Mark Richard James; Williams, Matthew; Williams, Mike; Williams, Timothy; Wilson, Fergus; Wimberley, Jack; Winn, Michael Andreas; Wishahi, Julian; Wislicki, Wojciech; Witek, Mariusz; Wormser, Guy; Wotton, Stephen; Wraight, Kenneth; Wyllie, Kenneth; Xie, Yuehong; Xu, Zhirui; Yang, Zhenwei; Yang, Zishuo; Yao, Yuezhe; Yin, Hang; Yu, Jiesheng; Yuan, Xuhao; Yushchenko, Oleg; Zarebski, Kristian Alexander; Zavertyaev, Mikhail; Zhang, Liming; Zhang, Yanxi; Zhelezov, Alexey; Zheng, Yangheng; Zhu, Xianglei; Zhukov, Valery; Zonneveld, Jennifer Brigitta; Zucchelli, Stefano

    2018-04-26

    The ratio of branching fractions R(D*-)≡B(B0→D*-τ+ντ)/B(B0→D*-μ+νμ) is measured using a data sample of proton-proton collisions collected with the LHCb detector at center-of-mass energies of 7 and 8 TeV, corresponding to an integrated luminosity of 3  fb-1. For the first time, R(D*-) is determined using the τ-lepton decays with three charged pions in the final state. The B0→D*-τ+ντ yield is normalized to that of the B0→D*-π+π-π+ mode, providing a measurement of B(B0→D*-τ+ντ)/B(B0→D*-π+π-π+)=1.97±0.13±0.18, where the first uncertainty is statistical and the second systematic. The value of B(B0→D*-τ+ντ)=(1.42±0.094±0.129±0.054)% is obtained, where the third uncertainty is due to the limited knowledge of the branching fraction of the normalization mode. Using the well-measured branching fraction of the B0→D*-μ+νμ decay, a value of R(D*-)=0.291±0.019±0.026±0.013 is established, where the third uncertainty is due to the limited knowledge of the branching frac...

  4. Measurements of Relative Biological Effectiveness and Oxygen Enhancement Ratio of Fast Neutrons of Different Energies

    Energy Technology Data Exchange (ETDEWEB)

    Barendsen, G. W.; Broerse, J. J. [Radiobiological Institute of the Health Research Council TNO, Rijswijk (ZH) (Netherlands)

    1968-03-15

    Impairment of the reproductive capacity of cultured cells of human kidney origin (T-l{sub g} cells) has been measured by the Puck cloning technique. From the dose-survival curves obtained in these experiments by irradiation of cells in equilibrium with air and nitrogen, respectively, the relative biological effectiveness (RBE) and the oxygen enhancement ratios (OER) were determined for different beams of fast neutrons. Monoenergetic neutrons of 3 and 15 MeV energy, fission spectrum fast neutrons (mean energy about 1.5 MeV), neutrons produced by bombarding Be with cyclotron-accelerated 16 MeV deuterons (mean energy about 6 MeV) and neutrons produced by bombarding Be with cyclotron- accelerated 20 MeV {sup 3}He ions (mean energy about 10 MeV) have been compared with 250 kVp X-rays as a standard reference. The RBE for 50% cell survival varies from 4.7 for fission-spectrum fast neutrons to 2.7 for 15 MeV monoenergetic neutrons. The OER is not strongly dependent on the neutron energy for the various beams investigated. For the neutrons with the highest and lowest energies used OER values of 1.6 {+-} 0.2 and 1.5 {+-} 0.1 were measured. An interpretation of these data on the basis of the shapes of the LET spectra is proposed and an approximate verification of this hypothesis is provided from measurements in which secondary particle equilibrium was either provided for or deliberately eliminated. (author)

  5. Forensic analysis of explosives using isotope ratio mass spectrometry (IRMS)--part 1: instrument validation of the DELTAplusXP IRMS for bulk nitrogen isotope ratio measurements.

    Science.gov (United States)

    Benson, Sarah J; Lennard, Christopher J; Hill, David M; Maynard, Philip; Roux, Claude

    2010-01-01

    A significant amount of research has been conducted into the use of stable isotopes to assist in determining the origin of various materials. The research conducted in the forensic field shows the potential of isotope ratio mass spectrometry (IRMS) to provide a level of discrimination not achievable utilizing traditional forensic techniques. Despite the research there have been few, if any, publications addressing the validation and measurement uncertainty of the technique for forensic applications. This study, the first in a planned series, presents validation data for the measurement of bulk nitrogen isotope ratios in ammonium nitrate (AN) using the DELTA(plus)XP (Thermo Finnigan) IRMS instrument equipped with a ConFlo III interface and FlashEA 1112 elemental analyzer (EA). Appropriate laboratory standards, analytical methods and correction calculations were developed and evaluated. A validation protocol was developed in line with the guidelines provided by the National Association of Testing Authorities, Australia (NATA). Performance characteristics including: accuracy, precision/repeatability, reproducibility/ruggedness, robustness, linear range, and measurement uncertainty were evaluated for the measurement of nitrogen isotope ratios in AN. AN (99.5%) and ammonium thiocyanate (99.99+%) were determined to be the most suitable laboratory standards and were calibrated against international standards (certified reference materials). All performance characteristics were within an acceptable range when potential uncertainties, including the manufacturer's uncertainty of the technique and standards, were taken into account. The experiments described in this article could be used as a model for validation of other instruments for similar purposes. Later studies in this series will address the more general issue of demonstrating that the IRMS technique is scientifically sound and fit-for-purpose in the forensic explosives analysis field.

  6. Risk Measure and Early-Warning System of China's Stock Market Based on Price-Earnings Ratio and Price-to-Book Ratio

    Directory of Open Access Journals (Sweden)

    Rongda Chen

    2014-01-01

    Full Text Available Based on the actual situation of China's stock market, this paper proposes a method for measuring the stock market's risk and early-warning methods which are based on price-to-earnings ratio and price-to-book ratio. The study found that the method of VaR can capture the bigger daily drops in a period, and if the drop is at the periodical top of the index, the probability of a sharp index decline will be very high. It also confirmed that the method is feasible and practical for people to use. In the long run, this method really can send early-warning signals of sharp decline; the warning levels increase as the index rises. The study also found that index will not fall after every warning but will continue going forward because of inertia, particularly during a big trend.

  7. Pitfalls with the use of enhancement ratios or normalized excess mixing ratios measured in plumes to characterize pollution sources and aging

    Directory of Open Access Journals (Sweden)

    R. J. Yokelson

    2013-08-01

    Full Text Available Normalized excess mixing ratios (NEMRs, also known as enhancement ratios, are a common way to characterize plumes of pollution in atmospheric research. As single-source pollutant plumes disperse in the atmosphere, they are diluted by mixing with the adjacent background air. Changes in the composition of this background air can cause large changes to the NEMR that is subsequently measured by remote-sensing, airborne, or ground-based instruments. This scenario is common when boundary layer plumes enter the free troposphere and could also impact long-range transport or plumes near the top of the troposphere. We provide a context for these issues and an example showing that neglect of this effect could lead to serious errors in data interpretation.

  8. Qualified measurement setup of polarization extinction ratio for Panda PMF with LC/UPC connector

    Science.gov (United States)

    Thongdaeng, Rutsuda; Worasucheep, Duang-rudee; Ngiwprom, Adisak

    2018-03-01

    Polarization Extinction Ratio (PER) is one of the key parameters for Polarization Maintaining Fiber (PMF) connector. Based on our previous studies, the bending radius of fiber greater than 1.5 cm will not affect the insertion loss of PMF [1]. Moreover, the measured PER of Panda PMF with LC/UPC connectors is more stable when that PMF is coiled around a hot rod with a minimum of 3-cm in diameter at 75°C temperature [2]. Hence, the hot rod with less constrained 6-cm in diameter at constant 75°C was selected for this PER measurement. Two PER setups were verified and compared for measuring LC/UPC PMF connectors. The Polarized Laser Source (PLS) at 1550 nm wavelength and PER meter from OZ Optics were used in both setups, in which the measured connector was connected to PLS at 0° angle while the other end was connected to PER meter. In order to qualify our setups, the percentage of Repeatability and Reproducibility (%R&R) were tested and calculated. In each setup, the PER measurement was repeated 3 trials by 3 appraisers using 10 LC/UPC PMF connectors (5 LC/UPC PMF patchcords with 3.5+/-0.5 meters in length) in random order. The 1st setup, PMF was coiled at a larger 20-cm diameter for 3 to 5 loops and left in room temperature during the test. The 2nd setup, PMF was coiled around a hot rod at constant 75°C with 6-cm diameter for 8 to 10 loops for at least 5 minutes before testing. There are 3 ranges of %R&R acceptation guide line: <10% is acceptable, between 10% - 30% is marginal, and <30% is unacceptable. According to our results, the %R&R of the 1st PER test setup was 16.2% as marginality, and the 2nd PER test setup was 8.9% as acceptance. Thus, providing the better repeatability and reproducibility, this 2nd PER test setup having PMF coiled around a hot rod at constant 75°C with 6-cm diameter was selected for our next study of the impact of hot temperature on PER in LC/UPC PMF connector.

  9. The Multidimensionality of Prosocial Behaviors and Evidence of Measurement Equivalence in Mexican American and European American Early Adolescents

    Science.gov (United States)

    Carlo, Gustavo; Knight, George P.; McGinley, Meredith; Zamboanga, Byron L.; Jarvis, Lorna Hernandez

    2010-01-01

    There is growing recognition of the need to examine distinct forms of prosocial behaviors and to conduct research on prosocial behaviors among ethnic minorities. Middle school students (mean age = 12.67 years; 54% girls; European American, n = 290; Mexican American, n = 152) completed a multidimensional measure of prosocial behavior and measures…

  10. Influence of accommodative lag upon the far-gradient measurement of accommodative convergence to accommodation ratio in strabismic patients.

    Science.gov (United States)

    Miyata, Manabu; Hasebe, Satoshi; Ohtsuki, Hiroshi

    2006-01-01

    To determine the influence of the lag of accommodation (LOA) on the accommodative convergence to accommodation (AC/A) ratio measured by the far-gradient method in strabismic patients. The AC/A ratio was measured with a distance target viewed with and without -3.00 diopter (D) addition lenses in 63 patients with different types of strabismus (age range, 7-34 years; range of strabismic angle, -60 to +40 prism diopters; refractive error range, -7.33 to +6.63 D). The LOA for the same lens was measured with an open-view-type autorefractometer. The stimulus AC/A ratio and the AC/A ratio adjusted by the individually measured LOA (adjusted AC/A ratio) were compared. The mean +/- SD of the LOA to the -3.00 D lenses was 1.06 +/- 0.43 D. The mean adjusted AC/A ratio was 41% greater than the stimulus AC/A ratio. The LOA differed widely among patients (0.13 to 2.14 D), and a large LOA tended to appear in myopic or young patients. The AC/A ratio obtained using the conventional far-gradient method is significantly biased by the LOA, and thus does not always represent the actual relationship between accommodation and vergence control systems. Copyright Japanese Ophthalmological Society 2006.

  11. Investigating measurement equivalence of visual analogue scales and Likert-type scales in Internet-based personality questionnaires.

    Science.gov (United States)

    Kuhlmann, Tim; Dantlgraber, Michael; Reips, Ulf-Dietrich

    2017-12-01

    Visual analogue scales (VASs) have shown superior measurement qualities in comparison to traditional Likert-type response scales in previous studies. The present study expands the comparison of response scales to properties of Internet-based personality scales in a within-subjects design. A sample of 879 participants filled out an online questionnaire measuring Conscientiousness, Excitement Seeking, and Narcissism. The questionnaire contained all instruments in both answer scale versions in a counterbalanced design. Results show comparable reliabilities, means, and SDs for the VAS versions of the original scales, in comparison to Likert-type scales. To assess the validity of the measurements, age and gender were used as criteria, because all three constructs have shown non-zero correlations with age and gender in previous research. Both response scales showed a high overlap and the proposed relationships with age and gender. The associations were largely identical, with the exception of an increase in explained variance when predicting age from the VAS version of Excitement Seeking (B10 = 1318.95, ΔR(2) = .025). VASs showed similar properties to Likert-type response scales in most cases.

  12. Open-air ionisation chambers with walls of soft-tissue equivalent material for measuring photon doses

    International Nuclear Information System (INIS)

    Vialettes, H.; Anceau, J.C.; Grand, M.; Petit, G.

    1968-01-01

    The ionisation chambers presented in this report constitute a contribution to research into methods of carrying out correct determinations in the field of health physics. The use of a mixture of teflon containing 42.5 per cent by weight of carbon for the chamber walls makes it possible to measure directly the dose absorbed in air through 300 mg/cm 2 of soft tissue and, consequently, the dose absorbed in the soft tissues with a maximum error of 10 per cent for photon energies of between 10 keV and 10 MeV. Furthermore since this material does not contain hydrogen, the chamber has a sensitivity to neutrons which is much less than other chambers in current use. Finally the shape of these chambers has been studied with a view to obtaining a satisfactory measurement from the isotropy point of view; for example for gamma radiation of 27 keV, the 3 litre chamber is isotropic to within 10 per cent over 270 degrees, and the 12 litre chamber is isotropic to within 10 per cent over 300 degrees; for 1.25 MeV gamma radiation this range is extended over 330 degrees for the 3 litre chamber, and 360 degrees for the 12 litre chamber. This report presents the measurements carried out with these chambers as well as the results obtained. These results are then compared to those obtained with other chambers currently used in the field of health physics. (authors) [fr

  13. Shape coexistence from lifetime and branching-ratio measurements in "6"8","7"0Ni

    International Nuclear Information System (INIS)

    Crider, B. P.; Prokop, C. J.; Liddick, S. N.; Al-Shudifat, M.; Ayangeakaa, A. D.

    2016-01-01

    Shape coexistence near closed-shell nuclei, whereby states associated with deformed shapes appear at relatively low excitation energy alongside spherical ones, is indicative of the rapid change in structure that can occur with the addition or removal of a few protons or neutrons. Near "6"8Ni (Z=28, N=40), the identification of shape coexistence hinges on hitherto undetermined transition rates to and from low-energy 0+ states. In "6"8","7"0Ni, new lifetimes and branching ratios have been measured. These data enable quantitative descriptions of the 0+ states through the deduced transition rates and serve as sensitive probes for characterizing their nuclear wave functions. The results are compared to, and consistent with, large-scale shell-model calculations which predict shape coexistence. With the firm identification of this phenomenon near "6"8Ni, shape coexistence is now observed in all currently accessible regions of the nuclear chart with closed proton shells and mid-shell neutrons.

  14. Measurement system analysis (MSA) of the isotopic ratio for uranium isotope enrichment process control

    Energy Technology Data Exchange (ETDEWEB)

    Medeiros, Josue C. de; Barbosa, Rodrigo A.; Carnaval, Joao Paulo R., E-mail: josue@inb.gov.br, E-mail: rodrigobarbosa@inb.gov.br, E-mail: joaocarnaval@inb.gov.br [Industrias Nucleares do Brasil (INB), Rezende, RJ (Brazil)

    2013-07-01

    Currently, one of the stages in nuclear fuel cycle development is the process of uranium isotope enrichment, which will provide the amount of low enriched uranium for the nuclear fuel production to supply 100% Angra 1 and 20% Angra 2 demands. Determination of isotopic ration n({sup 235}U)/n({sup 238}U) in uranium hexafluoride (UF{sub 6} - used as process gas) is essential in order to control of enrichment process of isotopic separation by gaseous centrifugation cascades. The uranium hexafluoride process is performed by gas continuous feeding in separation unit which uses the centrifuge force principle, establishing a density gradient in a gas containing components of different molecular weights. The elemental separation effect occurs in a single ultracentrifuge that results in a partial separation of the feed in two fractions: an enriched on (product) and another depleted (waste) in the desired isotope ({sup 235}UF{sub 6}). Industrias Nucleares do Brasil (INB) has used quadrupole mass spectrometry (QMS) by electron impact (EI) to perform isotopic ratio n({sup 235}U)/n({sup 238}U) analysis in the process. The decision of adjustments and change te input variables are based on the results presented in these analysis. A study of stability, bias and linearity determination has been performed in order to evaluate the applied method, variations and systematic errors in the measurement system. The software used to analyze the techniques above was the Minitab 15. (author)

  15. Measurement of the ratio of liquid to solid phases in a continuous ingot

    International Nuclear Information System (INIS)

    Deryabina, G.N.; Ripp, A.G.

    1980-01-01

    A radiometric method of measuring the ratio of liquid and solid phases (crust thickness) in a continuous ingot for automation of the continuous steel casting process, has been proposed. The essence of the method is, that radiation flux, bearing information on the object tested, is transformed in a succession of electric pulses, which is processed afterwords for obtaining necessary information. In this case either the flux of non-scattered radiation, passed through the object, or the flux of single-scattered radiation reflected from the object is registered. Block-diagram and specifications of a radiometric device with the Co source of 50 gxequiv. Ra activity developed for this purpose are presented. The technique for calibration ob the device and the results of its tests, are described. It is shown, that introduction of such devices for the control crust thickness at the installations of continuous steel casting of metallurgical works would permit to exercise casting in the optimum regime, to exclude metal leakage, to increase its quality and yield of the useful metal

  16. Alternatives to isotope ratio mass spectrometry for the measurement of deuterium content of body water

    International Nuclear Information System (INIS)

    Bluck, L.J.C.

    2000-01-01

    The measurement of breast milk intake using the isotope dilution techniques is now well established. The methodology involves the administration of a bolus of tracer followed by observation of the kinetics of its passage though the system. For example in the popular 'dose to the mother' method a dose of labeled water is administered to the mother, and over the following days samples of body fluids are taken and the concentration of tracer determined in order to establish the rate of loss of tracer from her body. Likewise samples are taken from the breast fed infant in order to determine the rates of tracer intake and subsequent loss. Deuterium is the tracer of choice for these experiments since it is non-radioactive, and therefore suitable for use in these vulnerable subject groups, and also because of its relative cheapness. Conventionally isotope ratio mass spectrometry (IRMS) has been used for the determination of the amount of deuterium in the body fluids. However this methodology is expensive (an instrument might typically cost US$ 150,000), and it requires a considerable amount of dedicated technical expertise for its operation. Consequently such instrumentation is not widely available, and this has limited the number and scope of studies using this technique. Recently there have been reports of possible alternative technologies for the determination of deuterium in body water which appear attractive because of the wider general availability of the equipment required. It is the purpose of this report to assess these reported methods for their suitability for breast milk intake measurements

  17. The day to night absorption ratio in auroral and subauroral zone riometer measurements during auroral absorption

    International Nuclear Information System (INIS)

    Ranta, H.; Ranta, A.; Rosenberg, T.J.

    1984-01-01

    The day to night ratio of auroral absorption has been studied using data from auroral and subauroral latitudes and by application of different kinds of statistical analyses. Ratios between 0.5 and 3.0 are obtained, depending on the criteria applied to the selection of data. Previous studies obtained similar ratios, but reached different conclusions about the effective solar control of auroral absorption. It is concluded here that evidence of solar control of the day to night ratio of auroral absorption, or the lack thereof, cannot be extracted by these statistical analyses. (author)

  18. Measurement and Study of Lidar Ratio by Using a Raman Lidar in Central China

    Directory of Open Access Journals (Sweden)

    Wei Wang

    2016-05-01

    Full Text Available We comprehensively evaluated particle lidar ratios (i.e., particle extinction to backscatter ratio at 532 nm over Wuhan in Central China by using a Raman lidar from July 2013 to May 2015. We utilized the Raman lidar data to obtain homogeneous aerosol lidar ratios near the surface through the Raman method during no-rain nights. The lidar ratios were approximately 57 ± 7 sr, 50 ± 5 sr, and 22 ± 4 sr under the three cases with obviously different pollution levels. The haze layer below 1.8 km has a large particle extinction coefficient (from 5.4e-4 m−1 to 1.6e-4 m−1 and particle backscatter coefficient (between 1.1e-05 m−1sr−1 and 1.7e-06 m−1sr−1 in the heavily polluted case. Furthermore, the particle lidar ratios varied according to season, especially between winter (57 ± 13 sr and summer (33 ± 10 sr. The seasonal variation in lidar ratios at Wuhan suggests that the East Asian monsoon significantly affects the primary aerosol types and aerosol optical properties in this region. The relationships between particle lidar ratios and wind indicate that large lidar ratio values correspond well with weak winds and strong northerly winds, whereas significantly low lidar ratio values are associated with prevailing southwesterly and southerly wind.

  19. Measurement and Study of Lidar Ratio by Using a Raman Lidar in Central China.

    Science.gov (United States)

    Wang, Wei; Gong, Wei; Mao, Feiyue; Pan, Zengxin; Liu, Boming

    2016-05-18

    We comprehensively evaluated particle lidar ratios (i.e., particle extinction to backscatter ratio) at 532 nm over Wuhan in Central China by using a Raman lidar from July 2013 to May 2015. We utilized the Raman lidar data to obtain homogeneous aerosol lidar ratios near the surface through the Raman method during no-rain nights. The lidar ratios were approximately 57 ± 7 sr, 50 ± 5 sr, and 22 ± 4 sr under the three cases with obviously different pollution levels. The haze layer below 1.8 km has a large particle extinction coefficient (from 5.4e-4 m(-1) to 1.6e-4 m(-1)) and particle backscatter coefficient (between 1.1e-05 m(-1)sr(-1) and 1.7e-06 m(-1)sr(-1)) in the heavily polluted case. Furthermore, the particle lidar ratios varied according to season, especially between winter (57 ± 13 sr) and summer (33 ± 10 sr). The seasonal variation in lidar ratios at Wuhan suggests that the East Asian monsoon significantly affects the primary aerosol types and aerosol optical properties in this region. The relationships between particle lidar ratios and wind indicate that large lidar ratio values correspond well with weak winds and strong northerly winds, whereas significantly low lidar ratio values are associated with prevailing southwesterly and southerly wind.

  20. Determination of dose equivalent with tissue-equivalent proportional counters

    International Nuclear Information System (INIS)

    Dietze, G.; Schuhmacher, H.; Menzel, H.G.

    1989-01-01

    Low pressure tissue-equivalent proportional counters (TEPC) are instruments based on the cavity chamber principle and provide spectral information on the energy loss of single charged particles crossing the cavity. Hence such detectors measure absorbed dose or kerma and are able to provide estimates on radiation quality. During recent years TEPC based instruments have been developed for radiation protection applications in photon and neutron fields. This was mainly based on the expectation that the energy dependence of their dose equivalent response is smaller than that of other instruments in use. Recently, such instruments have been investigated by intercomparison measurements in various neutron and photon fields. Although their principles of measurements are more closely related to the definition of dose equivalent quantities than those of other existing dosemeters, there are distinct differences and limitations with respect to the irradiation geometry and the determination of the quality factor. The application of such instruments for measuring ambient dose equivalent is discussed. (author)

  1. Metric and structural equivalence of core cognitive abilities measured with the Wechsler Adult Intelligence Scale-III in the United States and Australia.

    Science.gov (United States)

    Bowden, Stephen C; Lissner, Dianne; McCarthy, Kerri A L; Weiss, Lawrence G; Holdnack, James A

    2007-10-01

    Equivalence of the psychological model underlying Wechsler Adult Intelligence Scale-Third Edition (WAIS-III) scores obtained in the United States and Australia was examined in this study. Examination of metric invariance involves testing the hypothesis that all components of the measurement model relating observed scores to latent variables are numerically equal in different samples. The assumption of metric invariance is necessary for interpretation of scores derived from research studies that seek to generalize patterns of convergent and divergent validity and patterns of deficit or disability. An Australian community volunteer sample was compared to the US standardization data. A pattern of strict metric invariance was observed across samples. In addition, when the effects of different demographic characteristics of the US and Australian samples were included, structural parameters reflecting values of the latent cognitive variables were found not to differ. These results provide important evidence for the equivalence of measurement of core cognitive abilities with the WAIS-III and suggest that latent cognitive abilities in the US and Australia do not differ.

  2. Measurements of the Proton Elastic-Form-Factor Ratio μpGEp/GMp at Low Momentum Transfer

    International Nuclear Information System (INIS)

    Ron, G.; Piasetzky, E.; Pomerantz, I.; Shneor, R.; Glister, J.; Lee, B.; Choi, Seonho; Kang, H.; Oh, Y.; Song, J.; Yan, X.; Allada, K.; Dutta, C.; Armstrong, W.; Meziani, Z.-E.; Yao, H.; Arrington, J.; Solvignon, P.; Beck, A.; May-Tal Beck, S.

    2007-01-01

    High-precision measurements of the proton elastic form-factor ratio, μ p G E p /G M p , have been made at four-momentum transfer, Q 2 , values between 0.2 and 0.5 GeV 2 . The new data, while consistent with previous results, clearly show a ratio less than unity and significant differences from the central values of several recent phenomenological fits. By combining the new form-factor ratio data with an existing cross-section measurement, one finds that in this Q 2 range the deviation from unity is primarily due to G E p being smaller than expected

  3. Gating in time domain as a tool for improving the signal-to-noise ratio of beam transfer function measurements

    CERN Document Server

    Oeftiger, U; Caspers, Fritz

    1992-01-01

    For the measurement of Beam Transfer Functions the signal-to-noise ratio is of great importance. In order to get a reasonable quality of the measured data one may apply averaging and smoothing. In the following another technique called time gating to improve the quality of the measurement will be described. By this technique the measurement data are Fourier transformed and then modified in time domain. Tune gating suppresses signal contributions that are correlated to a time interval when no interesting information is expected. Afterivards an inverse Fourier transform leads to data in frequency domain with an improved signal to noise ratio.

  4. On the cross-sensitivity between water vapor mixing ratio and stable isotope measurements of in-situ analyzers

    KAUST Repository

    Parkes, Stephen

    2015-04-01

    In recent years there has been an increasing amount of water vapor stable isotope data collected using in-situ instrumentation. A number of papers have characterized the performance of these in-situ analyzers and suggested methods for calibrating raw measurements. The cross-sensitivity of the isotopic measurements on the mixing ratio has been shown to be a major uncertainty and a variety of techniques have been suggested to characterize this inaccuracy. However, most of these are based on relating isotopic ratios to water vapor mixing ratios from in-situ analyzers when the mixing ratio is varied and the isotopic composition kept constant. An additional correction for the span of the isotopic ratio scale is then applied by measuring different isotopic standards. Here we argue that the water vapor cross-sensitivity arises from different instrument responses (span and offset) of the parent H2O isotope and the heavier isotopes, rather than spectral overlap that could cause a true variation in the isotopic ratio with mixing ratio. This is especially relevant for commercial laser optical instruments where absorption lines are well resolved. Thus, the cross-sensitivity determined using more conventional techniques is dependent on the isotopic ratio of the standard used for the characterization, although errors are expected to be small. Consequently, the cross-sensitivity should be determined by characterizing the span and zero offset of each isotope mixing ratio. In fact, this technique makes the span correction for the isotopic ratio redundant. In this work we model the impact of changes in the span and offset of the heavy and light isotopes and illustrate the impact on the cross-sensitivity of the isotopic ratios on water vapor. This clearly shows the importance of determining the zero offset for the two isotopes. The cross-sensitivity of the isotopic ratios on water vapor is then characterized by determining the instrument response for the individual isotopes for a

  5. On the cross-sensitivity between water vapor mixing ratio and stable isotope measurements of in-situ analyzers

    KAUST Repository

    Parkes, Stephen; Wang,  Lixin; McCabe, Matthew

    2015-01-01

    In recent years there has been an increasing amount of water vapor stable isotope data collected using in-situ instrumentation. A number of papers have characterized the performance of these in-situ analyzers and suggested methods for calibrating raw measurements. The cross-sensitivity of the isotopic measurements on the mixing ratio has been shown to be a major uncertainty and a variety of techniques have been suggested to characterize this inaccuracy. However, most of these are based on relating isotopic ratios to water vapor mixing ratios from in-situ analyzers when the mixing ratio is varied and the isotopic composition kept constant. An additional correction for the span of the isotopic ratio scale is then applied by measuring different isotopic standards. Here we argue that the water vapor cross-sensitivity arises from different instrument responses (span and offset) of the parent H2O isotope and the heavier isotopes, rather than spectral overlap that could cause a true variation in the isotopic ratio with mixing ratio. This is especially relevant for commercial laser optical instruments where absorption lines are well resolved. Thus, the cross-sensitivity determined using more conventional techniques is dependent on the isotopic ratio of the standard used for the characterization, although errors are expected to be small. Consequently, the cross-sensitivity should be determined by characterizing the span and zero offset of each isotope mixing ratio. In fact, this technique makes the span correction for the isotopic ratio redundant. In this work we model the impact of changes in the span and offset of the heavy and light isotopes and illustrate the impact on the cross-sensitivity of the isotopic ratios on water vapor. This clearly shows the importance of determining the zero offset for the two isotopes. The cross-sensitivity of the isotopic ratios on water vapor is then characterized by determining the instrument response for the individual isotopes for a

  6. Cross-cultural measurement equivalence of the Revised Conflict Tactics Scales (CTS2 Portuguese version used to identify violence within couples

    Directory of Open Access Journals (Sweden)

    Claudia Leite Moraes

    2002-06-01

    Full Text Available Following a previous evaluation of concept, item and semantic equivalences, this paper assesses the measurement equivalence between a Portuguese version of Revised Conflict Tactics Scales (CTS2 and the original instrument conceived in English. The CTS2 has been widely used to tap violence between couples. An intra-observer reliability evaluation involved 165 replications carried out within a 24-48 hour period. Kappa point-estimates were above 0.75 for all scales except sexual coercion. The analysis of internal consistency concerned 768 subjects with complete sets of items. Kuder-Richardson-20 estimates ranged from 0.65 to 0.86. Results were similar to those found in the original instrument in English for the negotiation, psychological aggression and physical violence scales, yet not so for the sexual coercion and injury scales. Factor analysis identified factors with a recognizable correspondence to the underlying dimensions, although a few inconsistencies were detected. For the assessment of construct validity (n = 528 associations between the instrument's scales were evaluated, as well as the relationships between violence and putative underlying dimensions. Overall, the findings suggest that the version can be used in the Brazilian context, although further investigation should be carried out to unveil some important remaining issues.

  7. Airborne gamma-radiation snow water-equivalent and soil-moisture measurements and satellite areal extent of snow-cover measurements. A user's guide. Version 3.0

    International Nuclear Information System (INIS)

    Carroll, T.; Allen, M.

    1988-01-01

    The National Remote Sensing Hydrology Program is managed by the Office of Hydrology and consists of the Airborne Snow Survey Section and the Satellite Hydrology Section. The Airborne Snow Survey Section makes airborne snow water-equivalent and soil-moisture measurements over large areas of the country subject to a severe and chronic snowmelt flooding threat. The User's Guide is intended primarily to provide field hydrologists with some background on the technical and administrative aspects of the National Remote Sensing Hydrology Program. The guide summarizes the techniques and procedures used to make and distribute real-time, operational airborne snow water-equivalent measurements and satellite areal extent of snow-cover measurements made over large areas of the country. The current airborne and satellite databases are summarized, and procedures to access the real-time observations through both AFOS and through a commercial, electronic bulletin board system are given in the appendices

  8. Measurement of the 13C/12C ratio of soil-plant individual sugars by gas chromatography/combustion/isotope-ratio mass spectrometry of silylated derivatives.

    Science.gov (United States)

    Derrien, Delphine; Balesdent, Jérôme; Marol, Christine; Santaella, Catherine

    2003-01-01

    Carbohydrate is an important pool in the terrestrial carbon cycle. The potential offered by natural and artificial 13C-labelling techniques should therefore be applied to the investigation of the dynamics of individual sugars in soils. For this reason, we evaluated the method of 13C sugar analysis by gas chromatography/combustion/isotope-ratio mass spectrometry (GC/C/IRMS) after hydrolysis and direct trimethylsilylation. Trimethylsilylation involved the addition of several carbon atoms per sugar. These atoms have to be taken into account in the estimation of the carbon isotope ratio. The analysis of standard and natural pentoses and hexoses of known 13C enrichments revealed that the number of analysed added carbon atoms was less than expected from stoichiometry. This was attributed to incomplete derivatization and/or incomplete oxidation of methylsilyl carbon before IRMS. Using a calibration of the number of analysed added carbon atoms, the isotope excess of enriched samples could be determined with a relative error close to 5%. Concerning the determination of natural abundances by GC/C/IRMS, we could measure the delta 13C of standard C3- and C4-derived sugars with an accuracy of +/-1.5 per thousand using the previous calibration. We were able to apply this technique to plant-soil systems labelled by pulse-chase of 13CO2, revealing the nature and dynamics of sugars in the plant rhizosphere. Copyright 2003 John Wiley & Sons, Ltd.

  9. High-precision half-life and branching-ratio measurements for superallowed Fermi β+ emitters at TRIUMF - ISAC

    Science.gov (United States)

    Laffoley, A. T.; Dunlop, R.; Finlay, P.; Grinyer, G. F.; Andreoiu, C.; Austin, R. A. E.; Ball, G. C.; Bandyopadhyay, D.; Blank, B.; Bouzomita, H.; Chagnon-Lessard, S.; Chester, A.; Cross, D. S.; Demand, G.; Diaz Varela, A.; Djongolov, M.; Ettenauer, S.; Garnsworthy, A. B.; Garrett, P. E.; Giovinazzo, J.; Glister, J.; Green, K. L.; Hackman, G.; Hadinia, B.; Jamieson, D. S.; Ketelhut, S.; Leach, K. G.; Leslie, J. R.; Pearson, C. J.; Phillips, A. A.; Rand, E. T.; Starosta, K.; Sumithrarachchi, C. S.; Svensson, C. E.; Tardiff, E. R.; Thomas, J. C.; Towner, I. S.; Triambak, S.; Unsworth, C.; Williams, S. J.; Wong, J.; Yates, S. W.; Zganjar, E. F.

    2014-03-01

    A program of high-precision half-life and branching-ratio measurements for superallowed Fermi β emitters is being carried out at TRIUMF's Isotope Separator and Accelerator (ISAC) radioactive ion beam facility. Recent half-life measurements for the superallowed decays of 14O, 18Ne, and 26Alm, as well as branching-ratio measurements for 26Alm and 74Rb are reported. These results provide demanding tests of the Standard Model and the theoretical isospin symmetry breaking (ISB) corrections in superallowed Fermi β decays.

  10. Measures of effect size for chi-squared and likelihood-ratio goodness-of-fit tests.

    Science.gov (United States)

    Johnston, Janis E; Berry, Kenneth J; Mielke, Paul W

    2006-10-01

    A fundamental shift in editorial policy for psychological journals was initiated when the fourth edition of the Publication Manual of the American Psychological Association (1994) placed emphasis on reporting measures of effect size. This paper presents measures of effect size for the chi-squared and the likelihood-ratio goodness-of-fit statistic tests.

  11. Measurements of Pu239:U235 fission ratio using foils at temperatures up to 400 deg. C

    Energy Technology Data Exchange (ETDEWEB)

    Carter, D H; Puckett, B J; Richards, A E [General Reactor Physics Division, Atomic Energy Establishment, Winfrith, Dorchester, Dorset (United Kingdom)

    1964-05-15

    The paper describes the use of activation foils for the measurement of Pu239:U235 fission ratios in subcritical lattices at temperatures up to 390 deg C. Counting techniques and the method of analysis of the results are described in detail and the results are compared with fission chamber measurements. (author) 4 refs., 6 figs., 7 tabs.

  12. Measurement of the ratio σ{tt}/σ{Z/γ{*}→ll} and precise extraction of the tt cross section.

    Science.gov (United States)

    Aaltonen, T; Adelman, J; Alvarez González, B; Amerio, S; Amidei, D; Anastassov, A; Annovi, A; Antos, J; Apollinari, G; Apresyan, A; Arisawa, T; Artikov, A; Asaadi, J; Ashmanskas, W; Attal, A; Aurisano, A; Azfar, F; Badgett, W; Barbaro-Galtieri, A; Barnes, V E; Barnett, B A; Barria, P; Bartos, P; Bauer, G; Beauchemin, P-H; Bedeschi, F; Beecher, D; Behari, S; Bellettini, G; Bellinger, J; Benjamin, D; Beretvas, A; Bhatti, A; Binkley, M; Bisello, D; Bizjak, I; Blair, R E; Blocker, C; Blumenfeld, B; Bocci, A; Bodek, A; Boisvert, V; Bortoletto, D; Boudreau, J; Boveia, A; Brau, B; Bridgeman, A; Brigliadori, L; Bromberg, C; Brubaker, E; Budagov, J; Budd, H S; Budd, S; Burkett, K; Busetto, G; Bussey, P; Buzatu, A; Byrum, K L; Cabrera, S; Calancha, C; Camarda, S; Campanelli, M; Campbell, M; Canelli, F; Canepa, A; Carls, B; Carlsmith, D; Carosi, R; Carrillo, S; Carron, S; Casal, B; Casarsa, M; Castro, A; Catastini, P; Cauz, D; Cavaliere, V; Cavalli-Sforza, M; Cerri, A; Cerrito, L; Chang, S H; Chen, Y C; Chertok, M; Chiarelli, G; Chlachidze, G; Chlebana, F; Cho, K; Chokheli, D; Chou, J P; Chung, K; Chung, W H; Chung, Y S; Chwalek, T; Ciobanu, C I; Ciocci, M A; Clark, A; Clark, D; Compostella, G; Convery, M E; Conway, J; Corbo, M; Cordelli, M; Cox, C A; Cox, D J; Crescioli, F; Cuenca Almenar, C; Cuevas, J; Culbertson, R; Cully, J C; Dagenhart, D; Datta, M; Davies, T; de Barbaro, P; De Cecco, S; Deisher, A; De Lorenzo, G; Dell'orso, M; Deluca, C; Demortier, L; Deng, J; Deninno, M; d'Errico, M; Di Canto, A; di Giovanni, G P; Di Ruzza, B; Dittmann, J R; D'Onofrio, M; Donati, S; Dong, P; Dorigo, T; Dube, S; Ebina, K; Elagin, A; Erbacher, R; Errede, D; Errede, S; Ershaidat, N; Eusebi, R; Fang, H C; Farrington, S; Fedorko, W T; Feild, R G; Feindt, M; Fernandez, J P; Ferrazza, C; Field, R; Flanagan, G; Forrest, R; Frank, M J; Franklin, M; Freeman, J C; Furic, I; Gallinaro, M; Galyardt, J; Garberson, F; Garcia, J E; Garfinkel, A F; Garosi, P; Gerberich, H; Gerdes, D; Gessler, A; Giagu, S; Giakoumopoulou, V; Giannetti, P; Gibson, K; Gimmell, J L; Ginsburg, C M; Giokaris, N; Giordani, M; Giromini, P; Giunta, M; Giurgiu, G; Glagolev, V; Glenzinski, D; Gold, M; Goldschmidt, N; Golossanov, A; Gomez, G; Gomez-Ceballos, G; Goncharov, M; González, O; Gorelov, I; Goshaw, A T; Goulianos, K; Gresele, A; Grinstein, S; Grosso-Pilcher, C; Group, R C; Grundler, U; Guimaraes da Costa, J; Gunay-Unalan, Z; Haber, C; Hahn, S R; Halkiadakis, E; Han, B-Y; Han, J Y; Happacher, F; Hara, K; Hare, D; Hare, M; Harr, R F; Hartz, M; Hatakeyama, K; Hays, C; Heck, M; Heinrich, J; Herndon, M; Heuser, J; Hewamanage, S; Hidas, D; Hill, C S; Hirschbuehl, D; Hocker, A; Hou, S; Houlden, M; Hsu, S-C; Hughes, R E; Hurwitz, M; Husemann, U; Hussein, M; Huston, J; Incandela, J; Introzzi, G; Iori, M; Ivanov, A; James, E; Jang, D; Jayatilaka, B; Jeon, E J; Jha, M K; Jindariani, S; Johnson, W; Jones, M; Joo, K K; Jun, S Y; Jung, J E; Junk, T R; Kamon, T; Kar, D; Karchin, P E; Kato, Y; Kephart, R; Ketchum, W; Keung, J; Khotilovich, V; Kilminster, B; Kim, D H; Kim, H S; Kim, H W; Kim, J E; Kim, M J; Kim, S B; Kim, S H; Kim, Y K; Kimura, N; Kirsch, L; Klimenko, S; Kondo, K; Kong, D J; Konigsberg, J; Korytov, A; Kotwal, A V; Kreps, M; Kroll, J; Krop, D; Krumnack, N; Kruse, M; Krutelyov, V; Kuhr, T; Kulkarni, N P; Kurata, M; Kwang, S; Laasanen, A T; Lami, S; Lammel, S; Lancaster, M; Lander, R L; Lannon, K; Lath, A; Latino, G; Lazzizzera, I; Lecompte, T; Lee, E; Lee, H S; Lee, J S; Lee, S W; Leone, S; Lewis, J D; Lin, C-J; Linacre, J; Lindgren, M; Lipeles, E; Lister, A; Litvintsev, D O; Liu, C; Liu, T; Lockyer, N S; Loginov, A; Lovas, L; Lucchesi, D; Lueck, J; Lujan, P; Lukens, P; Lungu, G; Lys, J; Lysak, R; Macqueen, D; Madrak, R; Maeshima, K; Makhoul, K; Maksimovic, P; Malde, S; Malik, S; Manca, G; Manousakis-Katsikakis, A; Margaroli, F; Marino, C; Marino, C P; Martin, A; Martin, V; Martínez, M; Martínez-Ballarín, R; Mastrandrea, P; Mathis, M; Mattson, M E; Mazzanti, P; McFarland, K S; McIntyre, P; McNulty, R; Mehta, A; Mehtala, P; Menzione, A; Mesropian, C; Miao, T; Mietlicki, D; Miladinovic, N; Miller, R; Mills, C; Milnik, M; Mitra, A; Mitselmakher, G; Miyake, H; Moed, S; Moggi, N; Mondragon, M N; Moon, C S; Moore, R; Morello, M J; Morlock, J; Movilla Fernandez, P; Mülmenstädt, J; Mukherjee, A; Muller, Th; Murat, P; Mussini, M; Nachtman, J; Nagai, Y; Naganoma, J; Nakamura, K; Nakano, I; Napier, A; Nett, J; Neu, C; Neubauer, M S; Neubauer, S; Nielsen, J; Nodulman, L; Norman, M; Norniella, O; Nurse, E; Oakes, L; Oh, S H; Oh, Y D; Oksuzian, I; Okusawa, T; Orava, R; Osterberg, K; Pagan Griso, S; Pagliarone, C; Palencia, E; Papadimitriou, V; Papaikonomou, A; Paramanov, A A; Parks, B; Pashapour, S; Patrick, J; Pauletta, G; Paulini, M; Paus, C; Peiffer, T; Pellett, D E; Penzo, A; Phillips, T J; Piacentino, G; Pianori, E; Pinera, L; Pitts, K; Plager, C; Pondrom, L; Potamianos, K; Poukhov, O; Prokoshin, F; Pronko, A; Ptohos, F; Pueschel, E; Punzi, G; Pursley, J; Rademacker, J; Rahaman, A; Ramakrishnan, V; Ranjan, N; Redondo, I; Renton, P; Renz, M; Rescigno, M; Richter, S; Rimondi, F; Ristori, L; Robson, A; Rodrigo, T; Rodriguez, T; Rogers, E; Rolli, S; Roser, R; Rossi, M; Rossin, R; Roy, P; Ruiz, A; Russ, J; Rusu, V; Rutherford, B; Saarikko, H; Safonov, A; Sakumoto, W K; Santi, L; Sartori, L; Sato, K; Savoy-Navarro, A; Schlabach, P; Schmidt, A; Schmidt, E E; Schmidt, M A; Schmidt, M P; Schmitt, M; Schwarz, T; Scodellaro, L; Scribano, A; Scuri, F; Sedov, A; Seidel, S; Seiya, Y; Semenov, A; Sexton-Kennedy, L; Sforza, F; Sfyrla, A; Shalhout, S Z; Shears, T; Shepard, P F; Shimojima, M; Shiraishi, S; Shochet, M; Shon, Y; Shreyber, I; Simonenko, A; Sinervo, P; Sisakyan, A; Slaughter, A J; Slaunwhite, J; Sliwa, K; Smith, J R; Snider, F D; Snihur, R; Soha, A; Somalwar, S; Sorin, V; Squillacioti, P; Stanitzki, M; St Denis, R; Stelzer, B; Stelzer-Chilton, O; Stentz, D; Strologas, J; Strycker, G L; Suh, J S; Sukhanov, A; Suslov, I; Taffard, A; Takashima, R; Takeuchi, Y; Tanaka, R; Tang, J; Tecchio, M; Teng, P K; Thom, J; Thome, J; Thompson, G A; Thomson, E; Tipton, P; Ttito-Guzmán, P; Tkaczyk, S; Toback, D; Tokar, S; Tollefson, K; Tomura, T; Tonelli, D; Torre, S; Torretta, D; Totaro, P; Tourneur, S; Trovato, M; Tsai, S-Y; Tu, Y; Turini, N; Ukegawa, F; Uozumi, S; van Remortel, N; Varganov, A; Vataga, E; Vázquez, F; Velev, G; Vellidis, C; Vidal, M; Vila, I; Vilar, R; Vogel, M; Volobouev, I; Volpi, G; Wagner, P; Wagner, R G; Wagner, R L; Wagner, W; Wagner-Kuhr, J; Wakisaka, T; Wallny, R; Wang, S M; Warburton, A; Waters, D; Weinberger, M; Weinelt, J; Wester, W C; Whitehouse, B; Whiteson, D; Wicklund, A B; Wicklund, E; Wilbur, S; Williams, G; Williams, H H; Wilson, P; Winer, B L; Wittich, P; Wolbers, S; Wolfe, C; Wolfe, H; Wright, T; Wu, X; Würthwein, F; Yagil, A; Yamamoto, K; Yamaoka, J; Yang, U K; Yang, Y C; Yao, W M; Yeh, G P; Yi, K; Yoh, J; Yorita, K; Yoshida, T; Yu, G B; Yu, I; Yu, S S; Yun, J C; Zanetti, A; Zeng, Y; Zhang, X; Zheng, Y; Zucchelli, S

    2010-07-02

    We report a measurement of the ratio of the tt to Z/γ{*} production cross sections in sqrt[s]=1.96  TeV pp collisions using data corresponding to an integrated luminosity of up to 4.6  fb{-1}, collected by the CDF II detector. The tt cross section ratio is measured using two complementary methods, a b-jet tagging measurement and a topological approach. By multiplying the ratios by the well-known theoretical Z/γ{*}→ll cross section predicted by the standard model, the extracted tt cross sections are effectively insensitive to the uncertainty on luminosity. A best linear unbiased estimate is used to combine both measurements with the result σ{tt}=7.70±0.52  pb, for a top-quark mass of 172.5  GeV/c{2}.

  13. Investigation of a new LiF TLD individual dosimeter for measuring personal dose equivalent Hp(d) on different phantoms

    International Nuclear Information System (INIS)

    Jin Hua

    1993-01-01

    The paper describes the design of a new LiF TL dosimeter optimized for measuring personal dose equivalent, H p (d). The results obtained with four types of different phantoms, i.e. a PMMA slab, water slab, ICRU sphere and Alderson Rando phantom, and pertinent conversion coefficients show, that the conversion coefficients for the TE slab phantom are suitable for the calibration of TLD individual dosimeters on a PMMA slab phantom. In the energy range 17 keV to 1250 keV the energy response for H 0 (10) and H p (0.07) is within-20% to 8.4% for frontal irradiation. For angles within +- 60 degree the dosimeters indicate H p (10) within 0 to 22.5%, and H p (0.07) within-11.1% to 1.3%. respectively

  14. Measurement equivalence of the KINDL questionnaire across child self-reports and parent proxy-reports: a comparison between item response theory and ordinal logistic regression.

    Science.gov (United States)

    Jafari, Peyman; Sharafi, Zahra; Bagheri, Zahra; Shalileh, Sara

    2014-06-01

    Measurement equivalence is a necessary assumption for meaningful comparison of pediatric quality of life rated by children and parents. In this study, differential item functioning (DIF) analysis is used to examine whether children and their parents respond consistently to the items in the KINDer Lebensqualitätsfragebogen (KINDL; in German, Children Quality of Life Questionnaire). Two DIF detection methods, graded response model (GRM) and ordinal logistic regression (OLR), were applied for comparability. The KINDL was completed by 1,086 school children and 1,061 of their parents. While the GRM revealed that 12 out of the 24 items were flagged with DIF, the OLR identified 14 out of the 24 items with DIF. Seven items with DIF and five items without DIF were common across the two methods, yielding a total agreement rate of 50 %. This study revealed that parent proxy-reports cannot be used as a substitute for a child's ratings in the KINDL.

  15. An assessment method of dose equivalent due to indoor 220Rn progeny by using 220Rn concentration measured at a 20 cm distance from wall

    International Nuclear Information System (INIS)

    Iida, T.; Ikebe, Y.; Okamoto, K.; Guo, Q.; Yamasaki, T.

    1996-01-01

    A pair of passive cup monitors with a different air exchange openings was developed for measuring simultaneously 222 Rn and 220 Rn concentrations. Indoor 220 Rn concentrations were very high in traditional Japanese dwellings with soil walls. The 220 Rn concentration decreases exponentially with the distance from wall. The effective diffusion coefficient of 220 Rn in dwelling and the exhalation rate of 220 Rn from wall were evaluated from the distribution of the 220 Rn concentrations. Then, indoor 220 Rn progeny concentration could be estimated from the 220 Rn concentration at a 20 cm distance from wall. From the results of the surveys. the average annual effective dose equivalent due to 220 Rn progeny was expected to be 0.67 mSv/year in the traditional Japanese dwellings. (author)

  16. Extinction-to-Backscatter Ratios of Saharan Dust Layers Derived from In-Situ Measurements and CALIPSO Overflights During NAMMA

    Science.gov (United States)

    Omar, Ali H.; Liu, Zhaoyan; Vaughan, Mark A.; Hu, Yongxiang; Ismail, Syed; Powell, Kathleen A.; Winker, David M.; Trepte, Charles R.; Anderson, Bruce E.

    2010-01-01

    We determine the aerosol extinction-to-backscatter (Sa) ratios of dust using airborne in-situ measurements of microphysical properties, and CALIPSO observations during the NASA African Monsoon Multidisciplinary Analyses (NAMMA). The NAMMA field experiment was conducted from Sal, Cape Verde during Aug-Sept 2006. Using CALIPSO measurements of the attenuated backscatter of lofted Saharan dust layers, we apply the transmittance technique to estimate dust Sa ratios at 532 nm and a 2-color method to determine the corresponding 1064 nm Sa. Using this method, we found dust Sa ratios of 39.8 plus or minus 1.4 sr and 51.8 plus or minus 3.6 sr at 532 nm and 1064 nm, respectively. Secondly, Sa ratios at both wavelengths is independently calculated using size distributions measured aboard the NASA DC-8 and estimates of Saharan dust complex refractive indices applied in a T-Matrix scheme. We found Sa ratios of 39.1 plus or minus 3.5 sr and 50.0 plus or minus 4 sr at 532 nm and 1064 nm, respectively, using the T-Matrix calculations applied to measured size spectra. Finally, in situ measurements of the total scattering (550 nm) and absorption coefficients (532 nm) are used to generate an extinction profile that is used to constrain the CALIPSO 532 nm extinction profile.

  17. Isotopic ratio measurement using a double focusing magnetic sector mass analyser with an inductively coupled plasma as an ion source

    International Nuclear Information System (INIS)

    Walder, A.J.; Freedman, P.A.

    1992-01-01

    An inductively coupled plasma source was coupled to a magnetic sector mass analyser equipped with seven Faraday detectors. An electrostatic filter located between the plasma source and the magnetic sector was used to create a double focusing system. Isotopic ratio measurements of uranium and lead standards revealed levels of internal and external precision comparable to those obtained using thermal inonization mass spectrometry. An external precision of 0.014% was obtained from the 235 U: 238 U measurement of six samples of a National Bureau of Standards (NBS) Standard Reference Material (SRM) U-500, while an RSD of 0.022% was obtained from the 206 Pb: 204 Pb measurement of six samples of NBS SRM Pb-981. Measured isotopic ratios deviated from the NBS value by approximately 0.9% per atomic mass unit. This deviation approximates to a linear function of mass bias and can therefore be corrected for by the analysis of standards. The analysis of NBS SRM Sr-987 revealed superior levels of internal and external precision. The normalization of the 87 Sr: 86 Sr ratio to the 86 Sr: 88 Sr ratio reduced the RSD to approximately 0.008%. The measured ratio was within 0.01% of the NBS value and the day-to-day reproducibility was consistent within one standard deviation. (author)

  18. One-Dimensional-Ratio Measures of Atrophy Progression in Multiple Sclerosis as Evaluated by Longitudinal Magnetic Resonance Imaging

    International Nuclear Information System (INIS)

    Martola, J.; Wiberg Kristoffersen, M.; Aspelin, P.; Stawiarz, L.; Fredrikson, S.; Hillert, J.; Bergstroem, J.; Flodmark, O.

    2009-01-01

    Background: For decades, normalized one-dimensional (1D) measures have been used in the evaluation of brain atrophy. In multiple sclerosis (MS), the use of normalized linear measures over longitudinal follow-up remains insufficiently documented. Purpose: To evaluate the association between different regional atrophy measures and disability in MS patients over four decades in a longitudinal cross-sectional study. Material and Methods: 37 consecutively selected MS patients were included. At baseline, patients had a range of disease duration (1-33 years) and age (24-65 years). Each patient was followed by magnetic resonance imaging (MRI) for a mean of 9.25 years (range 7.3-10 years). Four 1D measures were applied at three time points on axial 5-mm T1-weighted images. Three clinical MS subgroups were represented: relapsing-remitting MS (RRMS), secondary progressive MS (SPMS), and primary progressive MS (PPMS). Results: There were significant changes in all 1D ratios during follow-up. The Evans ratio (ER) and the bifrontal ratio (BFR) were associated with the development of disability. Changes of ER and BFR reflected more aggressive disease progression, as expressed by MS severity score (MSSS). Conclusion: All four normalized ratios showed uniform atrophy progression, suggesting a consistent rate of atrophy over long-term disease duration independent of MS course. Disability status correlated with 1D measures, suggesting that serial evaluation of Evans and bifrontal ratios might contribute to the radiological evaluation of MS patients

  19. First Measurement of the 14N/15N Ratio in the Analog of the Sun Progenitor OMC-2 FIR4

    Science.gov (United States)

    Kahane, Claudine; Jaber Al-Edhari, Ali; Ceccarelli, Cecilia; López-Sepulcre, Ana; Fontani, Francesco; Kama, Mihkel

    2018-01-01

    We present a complete census of the 14N/15N isotopic ratio in the most abundant N-bearing molecules toward the cold envelope of the protocluster OMC-2 FIR4, the best known Sun progenitor. To this scope, we analyzed the unbiased spectral survey obtained with the IRAM 30 m telescope at 3, 2, and 1 mm. We detected several lines of CN, HCN, HNC, HC3N, N2H+, and their respective 13C and 15N isotopologues. The lines’ relative fluxes are compatible with LTE conditions, and moderate line opacities have been corrected via a population diagram method or theoretical relative intensity ratios of the hyperfine structures. The five species lead to very similar 14N/15N isotopic ratios, without any systematic difference between amine- and nitrile-bearing species as previously found in other protostellar sources. The weighted average of the 14N/15N isotopic ratio is 270 ± 30. This 14N/15N value is remarkably consistent with the [250–350] range measured for the local galactic ratio but significantly differs from the ratio measured in comets (around 140). High-angular resolution observations are needed to examine whether this discrepancy is maintained at smaller scales. In addition, using the CN, HCN, and HC3N lines, we derived a 12C/13C isotopic ratio of 50 ± 5.

  20. A measurement of the ratio of W + 1 jet to W + 0 jets cross sections and comparisons to QCD

    International Nuclear Information System (INIS)

    Abachi, S.

    1996-07-01

    A preliminary measurement of the ratio, R 10 , of the production cross sections for W + 1 Jet and W + 0 Jets processes at √s = 1,800 GeV by the D0 Collaboration is presented. A comparison of this ratio is made to next-to-leading order calculations and the implications of these comparisons, especially for the extraction of a value for the strong coupling constant α s (M W 2 ), are discussed

  1. Combining tracer flux ratio methodology with low-flying aircraft measurements to estimate dairy farm CH4 emissions

    Science.gov (United States)

    Daube, C.; Conley, S.; Faloona, I. C.; Yacovitch, T. I.; Roscioli, J. R.; Morris, M.; Curry, J.; Arndt, C.; Herndon, S. C.

    2017-12-01

    Livestock activity, enteric fermentation of feed and anaerobic digestion of waste, contributes significantly to the methane budget of the United States (EPA, 2016). Studies question the reported magnitude of these methane sources (Miller et. al., 2013), calling for more detailed research of agricultural animals (Hristov, 2014). Tracer flux ratio is an attractive experimental method to bring to this problem because it does not rely on estimates of atmospheric dispersion. Collection of data occurred during one week at two dairy farms in central California (June, 2016). Each farm varied in size, layout, head count, and general operation. The tracer flux ratio method involves releasing ethane on-site with a known flow rate to serve as a tracer gas. Downwind mixed enhancements in ethane (from the tracer) and methane (from the dairy) were measured, and their ratio used to infer the unknown methane emission rate from the farm. An instrumented van drove transects downwind of each farm on public roads while tracer gases were released on-site, employing the tracer flux ratio methodology to assess simultaneous methane and tracer gas plumes. Flying circles around each farm, a small instrumented aircraft made measurements to perform a mass balance evaluation of methane gas. In the course of these two different methane quantification techniques, we were able to validate yet a third method: tracer flux ratio measured via aircraft. Ground-based tracer release rates were applied to the aircraft-observed methane-to-ethane ratios, yielding whole-site methane emission rates. Never before has the tracer flux ratio method been executed with aircraft measurements. Estimates from this new application closely resemble results from the standard ground-based technique to within their respective uncertainties. Incorporating this new dimension to the tracer flux ratio methodology provides additional context for local plume dynamics and validation of both ground and flight-based data.

  2. A measurement of the branching ratio Σ+→rhoγ/Σ+→rhoπ0

    International Nuclear Information System (INIS)

    1985-06-01

    In an experiment performed in the CERN SPS hyperon beam a value for the branching ratio, Σ + →rhoγ/Σ + →rhoπ 0 of (2.46 sub(-0.35)sup(+0.30))x10 -3 , has been obtained corresponding to a branching ratio Σ + →rhoγ/Σ + → all of (1.27 sub(-0.18)sup(+0.16))x10 -3 . This result is discussed in the context of present understanding of hyperon radiative decays. (author)

  3. Measurements of the Poisson ratio and fragility of glass-forming liquids

    DEFF Research Database (Denmark)

    Christensen, Tage Emil; Olsen, Niels Boye

    Recently much attention has been given to models and phenomenology of glass-forming liquids that correlates fast and slow degrees of freedom . In particular the Poisson ratio has been correlated with fragility. We present data on shear - and bulk modulus obtained by the techniques...... of the piezoelectric transducers PBG and PSG on a number of glass-forming liquids. Hereby the Poisson ratio can be found. Furthermore the PSG also gives the temperature dependence of shear viscosity and thereby the fragility. The validity of the conjectured relation is discussed...

  4. Reduction of determinate errors in mass bias-corrected isotope ratios measured using a multi-collector plasma mass spectrometer

    International Nuclear Information System (INIS)

    Doherty, W.

    2015-01-01

    A nebulizer-centric instrument response function model of the plasma mass spectrometer was combined with a signal drift model, and the result was used to identify the causes of the non-spectroscopic determinate errors remaining in mass bias-corrected Pb isotope ratios (Tl as internal standard) measured using a multi-collector plasma mass spectrometer. Model calculations, confirmed by measurement, show that the detectable time-dependent errors are a result of the combined effect of signal drift and differences in the coordinates of the Pb and Tl response function maxima (horizontal offset effect). If there are no horizontal offsets, then the mass bias-corrected isotope ratios are approximately constant in time. In the absence of signal drift, the response surface curvature and horizontal offset effects are responsible for proportional errors in the mass bias-corrected isotope ratios. The proportional errors will be different for different analyte isotope ratios and different at every instrument operating point. Consequently, mass bias coefficients calculated using different isotope ratios are not necessarily equal. The error analysis based on the combined model provides strong justification for recommending a three step correction procedure (mass bias correction, drift correction and a proportional error correction, in that order) for isotope ratio measurements using a multi-collector plasma mass spectrometer

  5. Uncertainties achievable for uranium isotope-amount ratios. Estimates based on the precision and accuracy of recent characterization measurements

    International Nuclear Information System (INIS)

    Mathew, K.J.; Essex, R.M.; Gradle, C.; Narayanan, U.

    2015-01-01

    Certified reference materials (CRMs) recently characterized by the NBL for isotope-amount ratios are: (i) CRM 112-A, Uranium (normal) Metal Assay and Isotopic Standard, (ii) CRM 115, Uranium (depleted) Metal Assay and Isotopic Standard, and (iii) CRM 116-A, Uranium (enriched) Metal Assay and Isotopic Standard. NBL also completed re-characterization of the isotope-amount ratios in CRM 125-A, Uranium (UO 2 ) Pellet Assay, Isotopic, and Radio-chronometric Standard. Three different TIMS analytical techniques were employed for the characterization analyses. The total evaporation technique was used for the major isotope-amount ratio measurement, the modified total evaporation technique was used for both the major and minor isotope-amount ratios, and minor isotope-amount ratios were also measured using a Conventional technique. Uncertainties for the characterization studies were calculated from the combined TIMS data sets following the ISO Guide to the expression of uncertainty in measurement. The uncertainty components for the isotope-amount ratio values are discussed. (author)

  6. Study of the matrix specific mass discrimination effects during inductively coupled plasma mass spectrometry isotope ratio measurements

    International Nuclear Information System (INIS)

    Vassileva, E.; Quetel, Ch.R.

    2004-01-01

    Sample matrix related effects on mass discrimination during inductively coupled plasma mass spectrometry (ICP-MS) isotope ratio measurements have only been rarely reported. However, they can lead to errors larger than the uncertainty claimed on the ratio results when not properly taken into account or corrected for. These matrix specific affects were experienced during an Isotope Dilution Mass Spectrometry (IDMS) campaign we carried out for the certification of the Cd amount content in some food digest samples (7% acidity and salts content around 450μg g -1 ). Dilution was not possible for Cd only present at the low ng g -1 level. Up to 1% difference was observed on Cd isotope ratio results between measurements performed directly or after matrix separation. This was a significant difference considering that less than 1.5% relative combined uncertainty was eventually estimated for these IDMS measurements. Similar results could be obtained either way after the implementation of necessary corrections. The direct measurement approach associated to a correction for mass discrimination effects using the food digest sample itself (and the IUPAC table values as reference for the natural Cd isotopic composition) was preferred as it was the easiest. Consequently, the impact of matrix effects on mass discrimination during isotope ratio measurements with two types of ICP- MS (quadrupole and magnetic sector instruments) was studied for 4 elements (Li, Cu, Cd and Tl). Samples of varying salinity (up to 0.25%) and acidity (up to 7%) characteristics were prepared using isotopic certified reference materials of these elements. The long term and short-term stability, respectively reproducibility and repeatability, of the results, as well as the evolution of the difference to certified ratio values were monitored. As expected the 13 investigated isotopic ratios were all sensitive to variations in salt and acid concentrations. Our experiments also showed that simultaneous variation

  7. Comparison of hamstring/quadriceps ratio between isoinertial and isokinetic measurements

    NARCIS (Netherlands)

    Da Silva, Bruna G C; Bottaro, Martim; Weber, Fernanda S.; Radaelli, Regis; Gaya, Anelise R.; Cardoso, Marcelo S.; Brown, Lee E.; Carregaro, Rodrigo; Pinto, Ronei S.

    2013-01-01

    OBJECTIVE: To determine the applicability and predictive accuracy of an isoinertial resistance machine for the assessment of hamstring/quadriceps conventional (concentric) ratio (CR). METHOD: Thirty-two resistance trained young men (23.53 ± 3.2 yrs) were tested using dedicated instruments to obtain

  8. The measurement of house prices : A review of the sale price appraisal ratio method

    NARCIS (Netherlands)

    De Haan, J.; Van der Wal, E.B.; De Vries, P.

    2009-01-01

    The sale price appraisal ratio (SPAR) method has been applied in a number of countries to construct house price indexes. This paper reviews the statistical and index number properties of the SPAR approach. Three types of SPAR indexes are distinguished: a weighted index, which aims at tracking the

  9. A Novel Frequency Measurement Method Suitable for a Large Frequency Ratio Condition

    Institute of Scientific and Technical Information of China (English)

    ZHOU Wei; XUAN Zong-Qiang; YU Jian-Guo; WANG Hai; ZHOU Hui; LI Zhi-Qi

    2004-01-01

    @@ As for the obstacles to direct comparison between superhigh and lower frequencies, we accomplish the accurate comparison between low and microwave frequencies with the 105 ratios of the operating frequencies on the basis of phase comparison between the signals whose frequencies are related by an arbitrary integer. This method is simple and accurate, and will be widely used as a special frequency comparison approach.

  10. High dynamic range isotope ratio measurements using an analog electron multiplier

    Czech Academy of Sciences Publication Activity Database

    Williams, P.; Lorinčík, Jan; Franzreb, K.; Herwig, R.

    2013-01-01

    Roč. 45, č. 1 (2013), s. 549-552 ISSN 0142-2421 R&D Projects: GA MŠk ME 894 Institutional support: RVO:67985882 Keywords : Isotope ratios * electron multiplier * dynamic range Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.393, year: 2013

  11. Measurement of Muscle Protein Fractional Synthetic Rate by Capillary Gas Chromatography/Combustion Isotope Ratio Mass Spectrometry

    OpenAIRE

    Yarasheski, Kevin E.; Smith, Kenneth; Rennie, Michael J.; Bier, Dennis M.

    1992-01-01

    The measurement of skeletal muscle protein fractional synthetic rate using an infusion of (1-13C)leucine and measuring the isotopic abundance of the tracer in skeletal muscle protein by preparative gas chromatography (GC)/ninhydrin isotope ratio mass spectrometry (IRMS) is laborious and subject to errors owing to contamination by 12C. The purpose of this study was to compare muscle (13C)leucine enrichment measured with the conventional preparative GC/ninhydrin IRMS approach to a new, continuo...

  12. Prospects for measuring the branching ratio of the rare B0s→μ+μ- decay with the ATLAS experiment

    International Nuclear Information System (INIS)

    Sipica, Valentin

    2011-09-01

    The Large Hadron Collider (LHC) located at the CERN laboratory in Geneva provides p-p collisions at a centre-of-mass energy of √(s)=7 TeV. The study of the rare B 0 s →μ + μ - decay is among the research topics of ATLAS, one of the main experiments at the LHC. This decay is highly suppressed in the Standard Model of particle physics and may give an indirect evidence for New Physics models. This PhD thesis investigates prospects for measuring the branching ratio of the B 0 s →μ + μ - decay with the ATLAS experiment. The analysis is based on Monte Carlo data, with p-p collisions generated at a centre-of-mass energy of √(s)=10 TeV. The strategy employed is to calculate the B 0 s →μ + μ - branching ratio relative to the branching ratio of the B + → J/ψ(μ + μ - )K + decay. The dominant background channel is the b anti b→μ + μ - X combinatorial background. True B 0 s →μ + μ - decay candidates are separated from the much larger amount of combinatorial background events using several discriminating quantities. Upper limits on the B 0 s → μ + μ - branching ratio are computed using a Bayesian and a frequentist method. The expected precision of the branching ratio measurement is estimated for different values of the integrated luminosity. An expected upper limit on the branching ratio is computed to BR(B 0 s →μ + μ - ) -8 at a 95% confidence level for 1 fb -1 . The precision of the ATLAS measurement of the branching ratio will reach a level compatible with the best current measurements with about 2-5 fb -1 of data.

  13. The social and community opportunities profile social inclusion measure: Structural equivalence and differential item functioning in community mental health residents in Hong Kong and the United Kingdom.

    Science.gov (United States)

    Huxley, Peter John; Chan, Kara; Chiu, Marcus; Ma, Yanni; Gaze, Sarah; Evans, Sherrill

    2016-03-01

    China's future major health problem will be the management of chronic diseases - of which mental health is a major one. An instrument is needed to measure mental health inclusion outcomes for mental health services in Hong Kong and mainland China as they strive to promote a more inclusive society for their citizens and particular disadvantaged groups. To report on the analysis of structural equivalence and item differentiation in two mentally unhealthy and one healthy sample in the United Kingdom and Hong Kong. The mental health sample in Hong Kong was made up of non-governmental organisation (NGO) referrals meeting the selection/exclusion criteria (being well enough to be interviewed, having a formal psychiatric diagnosis and living in the community). A similar sample in the United Kingdom meeting the same selection criteria was obtained from a community mental health organisation, equivalent to the NGOs in Hong Kong. Exploratory factor analysis and logistic regression were conducted. The single-variable, self-rated 'overall social inclusion' differs significantly between all of the samples, in the way we would expect from previous research, with the healthy population feeling more included than the serious mental illness (SMI) groups. In the exploratory factor analysis, the first two factors explain between a third and half of the variance, and the single variable which enters into all the analyses in the first factor is having friends to visit the home. All the regression models were significant; however, in Hong Kong sample, only one-fifth of the total variance is explained. The structural findings imply that the social and community opportunities profile-Chinese version (SCOPE-C) gives similar results when applied to another culture. As only one-fifth of the variance of 'overall inclusion' was explained in the Hong Kong sample, it may be that the instrument needs to be refined using different or additional items within the structural domains of inclusion.

  14. Psychological Measurement Needs Units, Ratios, and Real Quantities: A Commentary on Humphry

    Science.gov (United States)

    Kyngdon, Andrew

    2011-01-01

    Behavioral scientists have struggled with units of measurement for as long as they have struggled with measurement itself. Psychology's sole attempt at an explicit unit of measurement--the Lexile Framework for Reading (Stenner, Burdick, Sanford, & Burdick, 2006)--has been and continues to be ignored by the psychometric "cognoscenti."…

  15. Direct isotope ratio measurement of uranium metal by emission spectrometry on a laser-produced plasma

    International Nuclear Information System (INIS)

    Pietsch, W.; Petit, A.; Briand, A.

    1995-01-01

    The method of Optical Emission Spectrometry on a Laser-Produced Plasma (OES/LPP) at reduced pressure has been studied for the determination of the uranium isotope ratio ( 235 U/ 238 U). Spectral profiles of the investigated transition U-II 424.437 nm show the possibility to obtain an isotopic spectral resolution in a laser-produced plasma under exactly defined experimental conditions. Spectroscopic data and results are presented. (author)

  16. Measurement of the natural variation of 13C/12C isotope ratio in organic samples

    International Nuclear Information System (INIS)

    Ducatti, C.

    1977-01-01

    The isotopic ratio analysis for 13 C/ 12 C by mass spectrometry using a 'Working standard' allows the study of 13 C natural variation in organic material, with a total analytical error of less than 0,2%. Equations were derived in order to determine 13 C/ 12 C and 18 O/ 16 O ratios related to the 'working standard' CENA-std and to the international standard PDB. Isotope ratio values obtained with samples prepared in two different combustion apparatus were compared; also the values obtained preparing samples by acid decomposition of carbonaceous materials were compared with the values obtained in different international laboratories. Utilizing the methodology proposed, several leaves collected at different heights of different vegetal species, found 'inside' and 'outside' of the Ducke Forest Reserve, located in the Amazon region, are analysed. It is found that the 13 C natural variation depends upon metabolic process and environmental factors, both being factors which may be qualified as parcial influences on the CO 2 cycle in the forest. (author) [pt

  17. Can T1 w/T2 w ratio be used as a myelin-specific measure in subcortical structures? Comparisons between FSE-based T1 w/T2 w ratios, GRASE-based T1 w/T2 w ratios and multi-echo GRASE-based myelin water fractions.

    Science.gov (United States)

    Uddin, Md Nasir; Figley, Teresa D; Marrie, Ruth Ann; Figley, Chase R

    2018-03-01

    Given the growing popularity of T 1 -weighted/T 2 -weighted (T 1 w/T 2 w) ratio measurements, the objective of the current study was to evaluate the concordance between T 1 w/T 2 w ratios obtained using conventional fast spin echo (FSE) versus combined gradient and spin echo (GRASE) sequences for T 2 w image acquisition, and to compare the resulting T 1 w/T 2 w ratios with histologically validated myelin water fraction (MWF) measurements in several subcortical brain structures. In order to compare these measurements across a relatively wide range of myelin concentrations, whole-brain T 1 w magnetization prepared rapid acquisition gradient echo (MPRAGE), T 2 w FSE and three-dimensional multi-echo GRASE data were acquired from 10 participants with multiple sclerosis at 3 T. Then, after high-dimensional, non-linear warping, region of interest (ROI) analyses were performed to compare T 1 w/T 2 w ratios and MWF estimates (across participants and brain regions) in 11 bilateral white matter (WM) and four bilateral subcortical grey matter (SGM) structures extracted from the JHU_MNI_SS 'Eve' atlas. Although the GRASE sequence systematically underestimated T 1 w/T 2 w values compared to the FSE sequence (revealed by Bland-Altman and mountain plots), linear regressions across participants and ROIs revealed consistently high correlations between the two methods (r 2 = 0.62 for all ROIs, r 2 = 0.62 for WM structures and r 2 = 0.73 for SGM structures). However, correlations between either FSE-based or GRASE-based T 1 w/T 2 w ratios and MWFs were extremely low in WM structures (FSE-based, r 2 = 0.000020; GRASE-based, r 2 = 0.0014), low across all ROIs (FSE-based, r 2 = 0.053; GRASE-based, r 2 = 0.029) and moderate in SGM structures (FSE-based, r 2 = 0.20; GRASE-based, r 2 = 0.17). Overall, our findings indicated a high degree of correlation (but not equivalence) between FSE-based and GRASE-based T 1 w/T 2 w ratios, and low correlations between T 1 w/T 2 w ratios and MWFs. This

  18. Measurement of L3 subshell absorption jump ratios and jump factors for high Z elements using EDXRF technique

    International Nuclear Information System (INIS)

    Kaçal, M.R.

    2014-01-01

    Energy dispersive X-ray fluorescence technique (EDXRF) has been employed for measuring L 3 -subshell absorption jump ratios, r L 3 and jump factors, J L 3 for high Z elements. Jump factors and jump ratios for these elements have been determined by measuring L 3 subshell fluorescence parameters such as L 3 subshell X-ray production cross section σ L 3 , L 3 subshell fluorescence yield, ω L 3 , total L 3 subshell and higher subshells photoionization cross section σ L T . Measurements were performed using a Cd-109 radioactive point source and an Si(Li) detector in direct excitation experimental geometry. Measured values for jump factors and jump ratios have been compared with theoretically calculated and other experimental values. - Highlights: • This paper regards L 3 subshell absorption jump ratios and jump factors using the EDXRF method. • These parameters were measured using a new method. • This method is more useful than other methods which require much effort. • Results are in good agreement with theoretical and experimental values

  19. Laser Velocimeter Measurements in the Pump of an Automotive Torque Converter Part I – Effect of Speed Ratio

    Directory of Open Access Journals (Sweden)

    Steven B. Ainley

    2000-01-01

    Full Text Available A torque converter was tested at four turbine/pump rotational speed ratios (0.200, 0.400, 0.600, and 0.800 all with a constant pump rotational speed in order to determine the effect of speed ratio on the torque converter pump flow field. Laser velocimetry was used to measure three components of velocity within the pump and a shaft encoder was employed to record the instantaneous pump angular position. Shaft encoder information was correlated with measured velocities to develop flow field blade-to-blade profiles and vector plots. Measurements were obtained in both the pump mid- and exit planes for all four speed ratios. Results showed large separation regions and jet/wake flows throughout the pump. The midplane flow was found to have strong counter-clockwise secondary components and the exit plane flow had strong clockwise secondary components. Mass flows were calculated from the velocity data and were found to decrease as the speed ratio was increased. Also, the vorticity and slip factors were calculated from the experimental data and are included. The mid-plane slip factors compare favorably to those for conventional centrifugal pumps but less slip was present in the exit plane than the mid-plane. Neither the slip factor nor the vorticity were seen to be strongly affected by the speed ratio. Finally, the torque core-to-shell and blade-to-blade torque distributions are presented for both planes.

  20. Pupil to limbus ratio: Introducing a simple objective measure using two-box method for measuring early anisocoria and progress of pupillary change in the ICU

    Directory of Open Access Journals (Sweden)

    Deb Kumar Mojumder

    2015-01-01

    Full Text Available Introduction: Measurement of static pupillary size in the ICU is of importance in cases of acutely expanding intracranial mass lesions. The inaccuracies with subjective assessment of pupillary size by medical personnel preclude its use in emergent neurological situations. Objective: To determine if the ratio of pupil to limbus diameter (PLD ratio measured by a two-box method is a reliable measure of pupil size for detecting early anisocoria and measuring pupillary changes. Materials and Methods: The PLD ratio was defined as the ratio of the pupillary diameter measured at a para-horizontal axial plane with the limbus diameter measured at the same or parallel axial plane. A two-box method was used to estimate the diameters of imaged pupils. Eyes were imaged using an iPhone 4S cellphone camera. Background illumination was measured and kept constant. The pupils of a 78-year-old woman, who presented with a large intra-axial parenchymal hemorrhage, were imaged. The patient had left pupillary miosis in dark but not in bright light. After presenting this case along with the images of the pupillary examination, a group of 21 medical staff were asked several questions on the pupillary examination. Reliability of PLD ratio were assessed via standard error of mean (S.E.M of PLD ratios for 3 different subjects each imaged under constant illumination and fixation but from different angles to the optical axis. Results: Analysis of questionnaire data together with PLD ratios revealed that ~ 14% and 10% of participants could estimate the pupillary size in darkness and bright light respectively but none were simultaneously accurate indicating that subjective assessment of pupillary size was unreliable. The approach towards a systematic pupillary examination was inconsistent among the participants. The PLD ratio was found to be a reliable measure of pupillary size with standard error of mean below 0.1 mm for the three subjects tested. Conclusion: Static pupillary

  1. Equivalence principles and electromagnetism

    Science.gov (United States)

    Ni, W.-T.

    1977-01-01

    The implications of the weak equivalence principles are investigated in detail for electromagnetic systems in a general framework. In particular, it is shown that the universality of free-fall trajectories (Galileo weak equivalence principle) does not imply the validity of the Einstein equivalence principle. However, the Galileo principle plus the universality of free-fall rotation states does imply the Einstein principle.

  2. Vitamin A equivalency of beta-carotene in healthy adults: limitation of the extrinsic dual-isotope dilution technique to measure matrix effect.

    NARCIS (Netherlands)

    Loo-Bouwman, C.A. Van; West, C.E.; Breemen, R.B. van; Zhu, D.; Siebelink, E.; Versloot, P.; Hulshof, P.J.; Lieshout, M. van; Russel, F.G.M.; Schaafsma, G.; Naber, A.H.J.

    2009-01-01

    Data on the vitamin A equivalency of beta-carotene in food are inconsistent. We quantified the vitamin A equivalency (microg) of beta-carotene in two diets using the dual-isotope dilution technique and the oral-faecal balance technique. A diet-controlled, cross-over intervention study was conducted

  3. Vitamin A equivalency of ß-carotene in healthy adults: limitation of the extrinsic dual-isotope dilution technique to measure matrix effect

    NARCIS (Netherlands)

    Bouwman, C.A.; West, C.E.; Breemen, van R.B.; Zhu, D.; Siebelink, E.; Versloot, P.; Hulshof, P.J.M.; Lieshout, van M.; Russel, F.G.M.; Schaafsma, G.; Naber, T.H.J.

    2009-01-01

    Data on the vitamin A equivalency of ß-carotene in food are inconsistent. We quantified the vitamin A equivalency (¿g) of ß-carotene in two diets using the dual-isotope dilution technique and the oral¿faecal balance technique. A diet-controlled, cross-over intervention study was conducted in