WorldWideScience

Sample records for equipment safety devices

  1. NASA safety standard for lifting devices and equipment

    Science.gov (United States)

    1990-09-01

    NASA's minimum safety requirements are established for the design, testing, inspection, maintenance, certification, and use of overhead and gantry cranes (including top running monorail, underhung, and jib cranes), mobile cranes, derrick hoists, and special hoist supported personnel lifting devices (these do not include elevators, ground supported personnel lifts, or powered platforms). Minimum requirements are also addressed for the testing, inspection, and use of Hydra-sets, hooks, and slings. Safety standards are thoroughly detailed.

  2. Equipment abnormality monitoring device

    International Nuclear Information System (INIS)

    Ando, Yasumasa

    1991-01-01

    When an operator hears sounds in a plantsite, the operator compares normal sounds of equipment which he previously heard and remembered with sounds he actually hears, to judge if they are normal or abnormal. According to the method, there is a worry that abnormal conditions can not be appropriately judged in a case where the number of objective equipments is increased and in a case that the sounds are changed gradually slightly. Then, the device of the present invention comprises a plurality of monitors for monitoring the operation sound of equipments, a recording/reproducing device for recording and reproducing the signals, a selection device for selecting the reproducing signals among the recorded signals, an acoustic device for converting the signals to sounds, a switching device for switching the signals to be transmitted to the acoustic device between to signals of the monitor and the recording/reproducing signals. The abnormality of the equipments can be determined easily by comparing the sounds representing the operation conditions of equipments for controlling the plant operation and the sounds recorded in their normal conditions. (N.H.)

  3. 76 FR 23255 - Federal Motor Vehicle Safety Standards; Lamps, Reflective Devices, and Associated Equipment

    Science.gov (United States)

    2011-04-26

    ... petitions for reconsideration from Harley-Davidson Motor Company (January 18, 2008) and Ford Motor Company... [Docket No. NHTSA-2007-28322] Federal Motor Vehicle Safety Standards; Lamps, Reflective Devices, and... part, the petitions for reconsideration of the December 4, 2007, final rule reorganizing Federal Motor...

  4. 77 FR 71717 - Federal Motor Vehicle Safety Standards; Lamps, Reflective Devices, and Associated Equipment

    Science.gov (United States)

    2012-12-04

    ... compliance strategies, potentially imposing costs on manufacturers while not improving safety. V. Regulatory... tort cause of action is impliedly preempted. See Geier v. American Honda Motor Co., 529 U.S. 861 (2000...

  5. 76 FR 41181 - Federal Motor Vehicle Safety Standards; Lamps, Reflective Devices, and Associated Equipment

    Science.gov (United States)

    2011-07-13

    ... to restore the blue and green color boundaries to Federal Motor Vehicle Safety Standard (FMVSS) No... number in the heading of this document, by any of the following methods: Federal eRulemaking Portal: Go... comment, if submitted on behalf of an association, business, labor union, etc.). You may review DOT's...

  6. A novel mechanical design of broken rope protection device for enhancing the safety performances of overhead manned equipment in coal mine

    Directory of Open Access Journals (Sweden)

    Xiaoguang Zhang

    2015-08-01

    Full Text Available A novel mechanical design of the broken rope protection device is proposed to enhance the safety performances of the overhead manned equipment. According to the operating characteristics and functional requirements of the overhead manned equipment, a three-dimensional mechanical model of the broken rope protection device was redesigned. Based on the known parameters of the mechanical model, the stress and strength of the main components are readjusted using the statics characteristics of finite element analysis. To ensure the reliability of the control system of the broken rope protection device, the process of people’s falling, the response performance of the tension sensor, and the signal extraction of the broken rope are analyzed under different loading and unloading speeds. The working principle of the broken rope protection device is expounded in detail. The experimental results showed that better effect is obtained by the new broken rope protection device, which is characterized by good durability, low investment, and high reliability.

  7. ACED devices and SECAF supports for the control of structure, pipe network and equipment behaviour at seismic movements in order to enhance the safety margin

    International Nuclear Information System (INIS)

    Serban, Viorel; Prisecaru, I.; Cretu, D.; Moldoveanu, T.

    2002-01-01

    In order to enhance the safety margin of structure, pipe networks and equipment associated to the existing NPPs, the classic consolidation solutions are very expensive and many times, impossible to be implemented. Structures, pipe networks, systems and equipment have geometries imposed by the basic construction requirements, operating and safety requirements and their modifications is not always possible. In order to enhance the strength capacity of (new or old) structures, systems and equipment mechanical devices with controlled elasticity and damping (ACED) have been designed, constructed and experimented. These devices are capable to support very large static loads over which dynamic loads (shock, vibration and seismic movements) overlap (which are damped). To increase the strength capacity of (new or existing) pipe networks and equipment connecting with pipes, SECAF supports that allow displacements from thermal expansions with low reaction force have been designed, constructed and experimented. SECAF supports are capable elastically to take permanent loads over which shocks, vibrations and seismic movements (which are damp) overlap. ACED devices and SECAF supports can be used to rehabilitate the existing NPPs with law financial costs and an increase of their strength capacity up to 100% under seismic movements, shocks and vibrations. ACED devices and SECAF supports do not require maintenance, are not affected by presence of a radiation field and their estimated service-life is similar to the NPPs

  8. [Prevention of medical device-related adverse events in hospitals: Specifying the recommendations of the German Coalition for Patient Safety (APS) for users and operators of anaesthesia equipment].

    Science.gov (United States)

    Bohnet-Joschko, Sabine; Zippel, Claus; Siebert, Hartmut

    2015-01-01

    The use and organisation of medical technology has an important role to play for patient and user safety in anaesthesia. Specification of the recommendations of the German Coalition for Patient Safety (APS) for users and operators of anaesthesia equipment, explore opportunities and challenges for the safe use and organisation of anaesthesia devices. We conducted a literature search in Medline/PubMed for studies dealing with the APS recommendations for the prevention of medical device-related risks in the context of anaesthesia. In addition, we performed an internet search for reports and recommendations focusing on the use and organisation of medical devices in anaesthesia. Identified studies were grouped and assigned to the recommendations. The division into users and operators was maintained. Instruction and training in anaesthesia machines is sometimes of minor importance. Failure to perform functional testing seems to be a common cause of critical incidents in anaesthesia. There is a potential for reporting to the federal authority. Starting points for the safe operation of anaesthetic devices can be identified, in particular, at the interface of staff, organisation, and (anaesthesia) technology. The APS recommendations provide valuable information on promoting the safe use of medical devices and organisation in anaesthesia. The focus will be on risks relating to the application as well as on principles and materials for the safe operation of anaesthesia equipment. Copyright © 2015. Published by Elsevier GmbH.

  9. Optimization of safety equipment outages improves safety

    International Nuclear Information System (INIS)

    Cepin, Marko

    2002-01-01

    Testing and maintenance activities of safety equipment in nuclear power plants are an important potential for risk and cost reduction. An optimization method is presented based on the simulated annealing algorithm. The method determines the optimal schedule of safety equipment outages due to testing and maintenance based on minimization of selected risk measure. The mean value of the selected time dependent risk measure represents the objective function of the optimization. The time dependent function of the selected risk measure is obtained from probabilistic safety assessment, i.e. the fault tree analysis at the system level and the fault tree/event tree analysis at the plant level, both extended with inclusion of time requirements. Results of several examples showed that it is possible to reduce risk by application of the proposed method. Because of large uncertainties in the probabilistic safety assessment, the most important result of the method may not be a selection of the most suitable schedule of safety equipment outages among those, which results in similarly low risk. But, it may be a prevention of such schedules of safety equipment outages, which result in high risk. Such finding increases the importance of evaluation speed versus the requirement of getting always the global optimum no matter if it is only slightly better that certain local one

  10. Safety rod driving device

    International Nuclear Information System (INIS)

    Murakami, Kiyonobu; Kurosaki, Akira.

    1988-01-01

    Purpose: To rapidly insert safety rods for a criticality experiment device into a reactor core container to stop the criticality reaction thereby prevent reactivity accidents. Constitution: A cylinder device having a safety rod as a cylinder rod attached with a piston at one end is constituted. The piston is elevated by pressurized air and attracted and fixed by an electromagnet which is a stationary device disposed at the upper portion of the cylinder. If the current supply to the electromagnet is disconnected, the safety rod constituting the cylinder rod is fallen together with the piston to the lower portion of the cylinder. Since the cylinder rod driving device has neither electrical motor nor driving screw as in the conventional device, necessary space can be reduced and the weight is decreased. In addition, since the inside of the nuclear reactor can easily be shielded completely from the external atmosphere, leakage of radioactive materials can be prevented. (Horiuchi, T.)

  11. Inspection device for buried equipment

    International Nuclear Information System (INIS)

    Hanawa, Jun.

    1994-01-01

    In an inspection device for a buried equipment, a rail is suspended at the upper portion of a vessel of a pit-vessel type pump buried in a plant building floor, and a truck movable vertical in the vessel along the rail, and an ultrasonic wave probe contained in the truck and urged to the vessel by an electromagnet are disposed. In addition, an elevator moving vertically along a shaft is disposed, and an arm having the ultrasonic probe disposed at the end portion and driven by a piston are disposed to the elevator. The ultrasonic wave probe moves vertically together with the truck along the rail in the vessel while being urged to the vessel by the electromagnet to inspect and measure the state at the inner and outer surfaces of the vessel. Further, the length of the arm is controlled so as to set a predetermined distance between the ultrasonic wave probe and the vessel. Subsequently, the elevator is moved vertically along a shaft passing through a shaft hole of a mount, and the shaft is rotated thereby enabling to inspect and measure the state of the inner and outer surfaces of the vessel. (N.H.)

  12. Safety device of thermonuclear device

    International Nuclear Information System (INIS)

    Aoki, Isao; Ueda, Shuzo; Seki, Yasushi; Sakurai, Akiko; Kasahara, Fumio; Obara, Atsushi; Yamauchi, Michinori.

    1997-01-01

    The present invention provides a safety device against an event of intrusion of coolants in a vacuum vessel. Namely, a coolant supply system comprises cooling tubes for supplying coolants to main reactor structure components including a vacuum vessel. A detection means detects leakage of coolants in the vacuum vessel. A coolant supply control means controls the supply of coolants to the main reactor structural components based on the leakage detection signals of the detection means. A stagnated material discharging means discharges stagnated materials in the main reactor structural components caused by the leakage of coolants. The leakage of coolants (for example, water) in the vacuum vessel can thus be detected by the water detection device in the vacuum vessel. A control value of a coolant supply means is closed by the leakage detection signals. The supply of coolants to the main reactor structural components is restricted to suppress the leakage. The stagnated materials are discharged to a tank by way of a water draining valve. (I.S.)

  13. Special Equipment and/or Devices.

    Science.gov (United States)

    National Sanitation Foundation, Ann Arbor, MI.

    This standard covers the sanitation requirements for equipment and/or devices used in the storage, preparation, or handling of foods and beverages. The National Sanitation Foundation's basic criteria for the evaluation of special equipment and/or devices has been prepared to fulfill several specific needs, its major function being to serve as a…

  14. Discussion on the safety classification of nuclear safety mechanical equipment

    International Nuclear Information System (INIS)

    Shen Wei

    2010-01-01

    The purpose and definition of the equipment safety classification in nuclear plant are introduced. The differences of several safety classification criterions are compared, and the object of safety classification is determined. According to the regulation, the definition and category of the safety functions are represented. The safety classification method, safety classification process, safety class interface, and the requirement for the safety class mechanical equipment are explored. At last, the relation of the safety classification between the mechanical and electrical equipment is presented, and the relation of the safety classification between mechanical equipment and system is also presented. (author)

  15. Pump safety device

    International Nuclear Information System (INIS)

    Timmermans, Francis; Vandervorst, Jean.

    1981-01-01

    Safety device for longitudinally leak proofing the shaft of a pump in the event of the fracture of the dynamic seal separating the pump fluid high pressure chamber from the low pressure chamber. It is designed for fitting to the primary pumps of nuclear reactors. It includes a hollow cyclindrical piston located coaxially around the pump shaft and normally housed in a chamber provided for this purpose in the fixed housing of the dynamic seal, and means for moving this piston coaxially so as to compress a safety O ring between the shaft and the piston in the event of the dynamic seal failing [fr

  16. 30 CFR 250.611 - Traveling-block safety device.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Traveling-block safety device. 250.611 Section... Traveling-block safety device. After May 31, 1989, all units being used for well-workover operations which have both a traveling block and a crown block shall be equipped with a safety device which is designed...

  17. 30 CFR 250.511 - Traveling-block safety device.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Traveling-block safety device. 250.511 Section... Traveling-block safety device. All units being used for well-completion operations that have both a traveling block and a crown block must be equipped with a safety device that is designed to prevent the...

  18. Procurement strategic analysis of nuclear safety equipment

    International Nuclear Information System (INIS)

    Wu Caixia; Yang Haifeng; Li Xiaoyang; Li Shixin

    2013-01-01

    The nuclear power development plan in China puts forward a challenge on procurement of nuclear safety equipment. Based on the characteristics of the procurement of nuclear safety equipment, requirements are raised for procurement process, including further clarification of equipment technical specification, establishment and improvement of the expert database of the nuclear power industry, adoption of more reasonable evaluation method and establishment of a unified platform for nuclear power plants to procure nuclear safety equipment. This paper makes recommendation of procurement strategy for nuclear power production enterprises from following aspects, making a plan of procurement progress, dividing procurement packages rationally, establishing supplier database through qualification review and implementing classified management, promoting localization process of key equipment continually and further improving the system and mechanism of procurement of nuclear safety equipment. (authors)

  19. Safety status system for operating room devices.

    Science.gov (United States)

    Guédon, Annetje C P; Wauben, Linda S G L; Overvelde, Marlies; Blok, Joleen H; van der Elst, Maarten; Dankelman, Jenny; van den Dobbelsteen, John J

    2014-01-01

    Since the increase of the number of technological aids in the operating room (OR), equipment-related incidents have come to be a common kind of adverse events. This underlines the importance of adequate equipment management to improve the safety in the OR. A system was developed to monitor the safety status (periodic maintenance and registered malfunctions) of OR devices and to facilitate the notification of malfunctions. The objective was to assess whether the system is suitable for use in an busy OR setting and to analyse its effect on the notification of malfunctions. The system checks automatically the safety status of OR devices through constant communication with the technical facility management system, informs the OR staff real-time and facilitates notification of malfunctions. The system was tested for a pilot period of six months in four ORs of a Dutch teaching hospital and 17 users were interviewed on the usability of the system. The users provided positive feedback on the usability. For 86.6% of total time, the localisation of OR devices was accurate. 62 malfunctions of OR devices were reported, an increase of 12 notifications compared to the previous year. The safety status system was suitable for an OR complex, both from a usability and technical point of view, and an increase of reported malfunctions was observed. The system eases monitoring the safety status of equipment and is a promising tool to improve the safety related to OR devices.

  20. Development of superconducting equipment for fusion device

    International Nuclear Information System (INIS)

    Konno, Masayuki; Ueda, Toshio; Hiue, Hisaaki; Ohgushi, Kouzou

    1993-01-01

    At Fuji Electric Co., Ltd., the development of superconductivity was started from 1960, and superconducting equipment for fusion device has been developed for ten years. The superconducting equipment, which is developed for fusion by Fuji Electric Co., Ltd., are able to be grouped in three categories which are current lead, superconducting coil and superconducting bus-line. The current lead is an electrical feeder between a superconducting coil and an electrical power supply. The rated current of developed current lead is 30kA at continuous use and 100kA at short time use respectively. The advanced disk type coil is developed for the toroidal field coil and some coils are developed for critical current measurement. Superconductor is applied to the superconducting bus-line between the superconducting coils and the current leads, and the bus-line is being developed for the Large Helical Device. This report describes an abstract of these equipment. (author)

  1. Medical Device Safety

    Science.gov (United States)

    A medical device is any product used to diagnose, cure, or treat a condition, or to prevent disease. They ... may need one in a hospital. To use medical devices safely Know how your device works. Keep ...

  2. Safety in Cryogenics – Safety device sizing

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    The calculation is separated in three operations: o The estimation of the loads arriving on the component to protect, o The calculation of the mass flow to evacuate, o And the sizing of the safety device.

  3. Safety management of software-based equipment

    CERN Document Server

    Boulanger, Jean-Louis

    2013-01-01

    A review of the principles of the safety of software-based equipment, this book begins by presenting the definition principles of safety objectives. It then moves on to show how it is possible to define a safety architecture (including redundancy, diversification, error-detection techniques) on the basis of safety objectives and how to identify objectives related to software programs. From software objectives, the authors present the different safety techniques (fault detection, redundancy and quality control). "Certifiable system" aspects are taken into account throughout the book. C

  4. Device for diagnoising abnormalities of equipments

    International Nuclear Information System (INIS)

    Nakano, Hiroshi.

    1986-01-01

    Purpose: To measure the collision energy easily and at high accuracy by applying impact shocks at known collision energy from a simulated acoustic wave generator and using the generated acoustic signal as reference data. Constitution: A plurality of acoustic detectors are attached to the surface of a nuclear reactor pressure vessel. These acoustic detectors are connected respectively to an abnormality diagnosis device for equipments. Then, when metal obstacles collide against the inner surface of the reactor pressure vessel, acoustic signals generated upon collision are detected by the acoustic detectors and acoustic information thus obtained from the acoustic detectors determines the colliding position of the metal obstacles by means of the abnormality diagnosis device and then the collision energy is measured. In this case, by applying impact shocks at known collision energy near the colliding position of metal obstacles determined by the abnormality diagnosis device, collision energy can be determined at a higher accuracy. (Kawakami, Y.)

  5. The french safety approach regarding equipment qualification

    International Nuclear Information System (INIS)

    Jalouneix, J.; Deletre, G.; Henry, J.Y.; Rousseau, L.

    1989-10-01

    The qualification of the equipment, used in France on nuclear reactors and reactor components, is discussed. The approach on safety involves the qualification of mechanical and electrical components, under operating and under seismic conditions. The principles of the qualification program and the list of the equipment concerned, are given. The conditions in which qualification tests are performed and the methods applied, are summarized. The actions for preserving the qualification procedures, are considered

  6. Failure diagnosis aiding device for plant equipment

    International Nuclear Information System (INIS)

    Uhara, Yoshihiko.

    1990-01-01

    The present invention intends to improve the efficiency of trouble shooting for equipments of industrial plants such as nuclear power plants. The device of the present invention comprises an intelligence base and an inference mechanism base. The intelligence base comprises a rule base, an information storing section having a part frame and a working frame and a user's frame. The parts frame contains the failure rate on every parts and data on related operations. The working frame contains the importance and frequency of working. The user's frame contains parameters showing the extent of user's skills. The rule base, the parts frame and the working frame can be selected in accordance with the extent of the user's skill in the inference mechanism. With such a constitution, failures can be checked with the intelligence base in accordance with the knowledges for the failures of the equipments and the extent of user's skill by way of the inference mechanism. (I.S.)

  7. Seismic qualification of non-safety class equipment whose failure would damage safety class equipment

    International Nuclear Information System (INIS)

    LaSalle, F.R.

    1991-01-01

    Both Code of Federal Regulations, Title 10, Part 50, and US Department of Energy Order 6340.1A have requirements to assess the interaction of non-safety and safety class structures and equipment during a seismic event to maintain the safety function. At the Hanford Site, a cost effective program has been developed to perform the evaluation of non-safety class equipment. Seismic qualification is performed by analysis, test, or upgrading of the equipment to ensure the integrity of safety class structures and equipment. This paper gives a brief overview and synopsis that address design analysis guidelines including applied loading, damping values, component anchorage, allowable loads, and stresses. Test qualification of equipment and walkdown acceptance criteria for heating ampersand ventilation (H ampersand V) ducting, conduit, cable tray, missile zone of influence, as well as energy criteria are presented

  8. Electronic equipment and software for device 'FAZA'

    International Nuclear Information System (INIS)

    Avdeev, S.P.; Karnaukhov, V.A.; Kuznetsov, V.D.; Petrov, L.A.; Oeschler, H.; Lips, F.; Bart, R.

    1992-01-01

    Electronic equipment and software for the device FAZA are described. The device, designed for studying the nuclear multifragmentation process, consists of 5 time-of-flight telescopes, a position-sensitive avalanche chamber and 58 PM tubes. The time resolution of the time-of-flight telescopes is 0.5 ns, which allows a velocity resolution of 1.5%. The spatial resolution of the large avalanche counter is 4 mm, which allows angular resolution of 1 deg. Analogue signals from each PM tube come to two ADCs, to which strobes are supplied with a 400 ns shift. It allows codes corresponding to Cherenkov radiation and deexcitation of CsJ(Tl) to be distinguished in a two-dimensional plot. 8 refs.; 2 figs

  9. Safety requirements and feedback of commonly used material handling equipment

    International Nuclear Information System (INIS)

    Pathak, M.K.

    2009-01-01

    Different types of cranes, hoists, chain pulley blocks are the most commonly used material handling equipment in industry along with attachments like chains, wire rope slings, d-shackles, etc. These equipment are used at work for transferring loads from one place to another and attachments are used for anchoring, fixing or supporting the load. Selection of the correct equipment, identification of the equipment planning of material handling operation, examination/testing of the equipment, education and training of the persons engaged in operation of the material handling equipment can reduce the risks to safety of people in workplace. Different safety systems like boom angle indicator, overload tripping device, limit switches, etc. should be available in the cranes for their safe use. Safety requirement for safe operation of material handling equipment with emphasis on different cranes and attachments particularly wire rope slings and chain slings have been brought out in this paper. An attempt has also been made to bring out common nature of deficiencies observed during regulatory inspection carried out by AERB. (author)

  10. 30 CFR 77.410 - Mobile equipment; automatic warning devices.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Mobile equipment; automatic warning devices. 77... UNDERGROUND COAL MINES Safeguards for Mechanical Equipment § 77.410 Mobile equipment; automatic warning devices. (a) Mobile equipment such as front-end loaders, forklifts, tractors, graders, and trucks, except...

  11. Safety device for nuclear reactor

    International Nuclear Information System (INIS)

    Jacquelin, Roland.

    1977-01-01

    This invention relates to a safety device for a nuclear reactor, particularly a liquid metal (generally sodium) cooled fast reactor. This safety device includes an absorbing element with a support head connected by a disconnectable connector formed by the armature of an electromagnet at the end of an axially mobile vertical control rod. This connection is so designed that in the event of it becoming disconnected, the absorbing element gravity slides in a passage through the reactor core into an open container [fr

  12. 49 CFR 238.230 - Safety appliances-new equipment.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Safety appliances-new equipment. 238.230 Section... I Passenger Equipment § 238.230 Safety appliances—new equipment. (a) Applicability. This section..., 2007, that is equipped with a safety appliance, required by the “manner of application” provisions in...

  13. Reactor safety device

    International Nuclear Information System (INIS)

    Okada, Yasumasa.

    1987-01-01

    Purpose: To scram control rods by processing signals from a plurality of temperature detectors and generating abnormal temperature warning upon occurrence of abnormal temperature in a nuclear reactor. Constitution: A temperature sensor comprising a plurality of reactors each having a magnetic body as the magnetic core having a curie point different from each other and corresponding to the abnormal temperature against which reactor core fuels have to be protected is disposed in an identical instrumentation well near the reactor core fuel outlet/inlet of a reactor. A temperature detection device actuated upon detection of an abnormal temperature by the abrupt reduction of the reactance of each of the reactors is disposed. An OR circuit and an AND circuit for conducting OR and AND operations for each of the abnormal temperature detection signals from the temperature detection device are disposed. The output from the OR circuit is used as the abnormal temperature warning signal, while the output from the AND circuit is utilized as a signal for actuating the scram operation of control rod drive mechanisms. Accordingly, it is possible to improve the reliability of the reactor scram system, particularly, improve the reliability under a high temperature atmosphere. (Kamimura, M.)

  14. Three equipment concepts for the Fusion Engineering Device

    International Nuclear Information System (INIS)

    Spampinato, P.T.; Masson, L.S.; Watts, K.D.; Grant, N.R.; Kuban, D.P.

    1982-01-01

    Maintenance equipment which is needed to remotely handle fusion device components is being conceptually developed for the Fusion Engineering Design Center. This will test the assumption that these equipment needs can be satisfied by present technology. In addition, the development of equipment conceptual designs will allow for cost estimates which have a much higher degree of certainty. Accurate equipment costs will be useful for assessments which trade off gains in availability as a function of increased investments in maintenance equipment

  15. Guideline on evaluation and acceptance of commercial grade digital equipment for nuclear safety applications

    International Nuclear Information System (INIS)

    1996-10-01

    Nuclear power plants are increasingly upgrading their instrumentation and control (I ampersand C) systems with commercial digital equipment, which allows them to continue meeting safety and reliability requirements while controlling operating costs. However, the use of commercial software-based devices for safety related applications has raised new issues that impact design, procurement, and licensing activities. This guideline describes a consistent, comprehensive approach for the evaluation and acceptance of commercial digital equipment for nuclear safety systems

  16. Pediatric interventional radiography equipment: safety considerations

    International Nuclear Information System (INIS)

    Strauss, Keith J.

    2006-01-01

    This paper discusses pediatric image quality and radiation dose considerations in state-of-the-art fluoroscopic imaging equipment. Although most fluoroscopes are capable of automatically providing good image quality on infants, toddlers, and small children, excessive radiation dose levels can result from design deficiencies of the imaging device or inappropriate configuration of the equipment's capabilities when imaging small body parts. Important design features and setup choices at installation and during the clinical use of the imaging device can improve image quality and reduce radiation exposure levels in pediatric patients. Pediatric radiologists and cardiologists, with the help of medical physicists, need to understand the issues involved in creating good image quality at reasonable pediatric patient doses. The control of radiographic technique factors by the generator of the imaging device must provide a large dynamic range of mAs values per exposure pulse during both fluoroscopy and image recording as a function of patient girth, which is the thickness of the patient in the posterior-anterior projection at the umbilicus (less than 10 cm to greater than 30 cm). The range of pulse widths must be limited to less than 10 ms in children to properly freeze patient motion. Variable rate pulsed fluoroscopy can be leveraged to reduce radiation dose to the patient and improve image quality. Three focal spots with nominal sizes of 0.3 mm to 1 mm are necessary on the pediatric unit. A second, lateral imaging plane might be necessary because of the child's limited tolerance of contrast medium. Spectral and spatial beam shaping can improve image quality while reducing the radiation dose. Finally, the level of entrance exposure to the image receptor of the fluoroscope as a function of operator choices, of added filter thickness, of selected pulse rate, of the selected field-of-view and of the patient girth all must be addressed at installation. (orig.)

  17. Safety device for nuclear reactors

    International Nuclear Information System (INIS)

    Gruhl, H.

    1974-01-01

    The safety device is used to capture fragments of the lid of a pressure vessel when this vessel ruptures. It consists of a catcher structure attached to the concrete vessel, which is open at the top, and surrounding the pressure vessel. The catcher structure in this case may be designed as a ring installed very close to the concrete vessel, as a closure plate or may be made of transverse beams arranged parallel to each other. It is anchored either rigidly or elastically to the concrete vessel by means of springs or to the foundation by means of steel stretching members. (DG) [de

  18. Plutonium finishing plant safety systems and equipment list

    International Nuclear Information System (INIS)

    Bergquist, G.G.

    1995-01-01

    The Safety Equipment List (SEL) supports Analysis Report (FSAR), WHC-SD-CP-SAR-021 and the Plutonium Finishing Plant Operational Safety Requirements (OSRs), WHC-SD-CP-OSR-010. The SEL is a breakdown and classification of all Safety Class 1, 2, and 3 equipment, components, or system at the Plutonium Finishing Plant complex

  19. Reliability analysis of PLC safety equipment

    Energy Technology Data Exchange (ETDEWEB)

    Yu, J.; Kim, J. Y. [Chungnam Nat. Univ., Daejeon (Korea, Republic of)

    2006-06-15

    FMEA analysis for Nuclear Safety Grade PLC, failure rate prediction for nuclear safety grade PLC, sensitivity analysis for components failure rate of nuclear safety grade PLC, unavailability analysis support for nuclear safety system.

  20. Reliability analysis of PLC safety equipment

    International Nuclear Information System (INIS)

    Yu, J.; Kim, J. Y.

    2006-06-01

    FMEA analysis for Nuclear Safety Grade PLC, failure rate prediction for nuclear safety grade PLC, sensitivity analysis for components failure rate of nuclear safety grade PLC, unavailability analysis support for nuclear safety system

  1. Equipment abnormality monitoring method and device therefor

    International Nuclear Information System (INIS)

    Yamada, Izumi; Asakura, Yamato; Uemura, Hiroshi; Uchida, Shunsuke; Oyamada, Osamu; Oyobe, Koji.

    1994-01-01

    In the present invention, it is judged whether the operation state of equipments used in a plant are normal or not by using learning performances. That is, a plurality of monitoring parameters are measured for an equipment. Previously determined monitoring parameters are extracted. A leaning mode or a monitoring mode is selected. In the leaning mode, based on the values of previously determined monitoring parameters, values of other monitoring parameters during normal states are learned. In the monitoring mode, based on the values of the previously determined monitoring parameters, typical values of other leaned monitoring parameters are outputted. The typical values of other normal monitoring parameters after learning and the values of other parameters at the present time are compared. If the values of the other parameters at the present time are out of normal range, it is judged as abnormal, and the result is alarmed and displayed. (I.S.)

  2. Sodium cleaning device for nuclear reactor equipments

    International Nuclear Information System (INIS)

    Fujisawa, Morio.

    1985-01-01

    Purpose: To enable sodium cleaning over the entire length of large size equipments such as control rod drives and primary coolant recycling pumps for use in FBR type reactors. Constitution: A plurality of warm water supply nozzles each having a valve are connected at varying height on the side of a cleaning tank, to which an exhaust line is connected. These nozzles are connected with an exhaust port at the bottom of the tank to constitute a pipeway for cleaning warm water recycling line including a water feed pump and a feedwater heater. The water level in the tank is changed stepwise by successively selecting the warm water feed nozzles. Further, the warm water in the tank is recyclically fed through the nozzles selected at each step of the water level through the recycle line while warming. On the other hand, the pressure inside the tank is reduced through the exhaust line, whereby the warm water in the tank is boiled at low temperature to clean-up sodium on the equipments to be cleaned over the entire length. (Horiuchi, T.)

  3. A Study on Performance and Safety Tests of Defibrillator Equipment

    Directory of Open Access Journals (Sweden)

    Tavakoli Golpaygani A.

    2017-12-01

    Full Text Available Introduction: Nowadays, more than 10,000 different types of medical devices can be found in hospitals. This way, medical electrical equipment is being employed in a wide variety of fields in medical sciences with different physiological effects and measurements. Hospitals and medical centers must ensure that their critical medical devices are safe, accurate, reliable and operational at the required level of performance. Defibrillators are critical resuscitation devices. The use of reliable defibirillators has led to more effective treatments and improved patient safety through better control and management of complications during Cardiopulmonary Resuscitation (CPR. Materials and Methods: The metrological reliability of twenty frequent use, manual defibrillators in use ten hospitals (4 private and 6 public in one of the provinces of Iran according to international and national standards was evaluated. Results: Quantitative analysis of control and instrument accuracy showed the amount of the obtained results in many units are critical which had less value over the standard limitations especially in devices with poor battery. For the accuracy of delivered energy analysis, only twelve units delivered acceptable output values and the precision in the output energy measurements especialy in weak battry condition, after activation of discharge alarm, were low. Conclusion: Obtained results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially for high risk instruments. It is also necessary to provide training courses on the fundumentals of operation and performane parameters for medical staff in the field of meterology in medicine and how one can get good accuracy results especially in high risk medical devices.

  4. A Study on Performance and Safety Tests of Defibrillator Equipment.

    Science.gov (United States)

    Tavakoli Golpaygani, A; Movahedi, M M; Reza, M

    2017-12-01

    Nowadays, more than 10,000 different types of medical devices can be found in hospitals. This way, medical electrical equipment is being employed in a wide variety of fields in medical sciences with different physiological effects and measurements. Hospitals and medical centers must ensure that their critical medical devices are safe, accurate, reliable and operational at the required level of performance. Defibrillators are critical resuscitation devices. The use of reliable defibirillators has led to more effective treatments and improved patient safety through better control and management of complications during Cardiopulmonary Resuscitation (CPR). The metrological reliability of twenty frequent use, manual defibrillators in use ten hospitals (4 private and 6 public) in one of the provinces of Iran according to international and national standards was evaluated. Quantitative analysis of control and instrument accuracy showed the amount of the obtained results in many units are critical which had less value over the standard limitations especially in devices with poor battery. For the accuracy of delivered energy analysis, only twelve units delivered acceptable output values and the precision in the output energy measurements especialy in weak battry condition, after activation of discharge alarm, were low. Obtained results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially for high risk instruments. It is also necessary to provide training courses on the fundumentals of operation and performane parameters for medical staff in the field of meterology in medicine and how one can get good accuracy results especially in high risk medical devices.

  5. Safety of mechanical devices. Safety of automation systems

    International Nuclear Information System (INIS)

    Pahl, G.; Schweizer, G.; Kapp, K.

    1985-01-01

    The paper deals with the classic procedures of safety engineering in the sectors mechanical engineering, electrical and energy engineering, construction and transport, medicine technology and process technology. Particular stress is laid on the safety of automation systems, control technology, protection of mechanical devices, reactor safety, mechanical constructions, transport systems, railway signalling devices, road traffic and protection at work in chemical plans. (DG) [de

  6. Experience of safety and performance improvement for fuel handling equipment

    International Nuclear Information System (INIS)

    Gyoon Chang, Sang; Hee Lee, Dae

    2014-01-01

    The purpose of this study is to provide experience of safety and performance improvement of fuel handling equipment for nuclear power plants in Korea. The fuel handling equipment, which is used as an important part of critical processes during the refueling outage, has been improved to enhance safety and to optimize fuel handling procedures. Results of data measured during the fuel reloading are incorporated into design changes. The safety and performance improvement for fuel handling equipment could be achieved by simply modifying the components and improving the interlock system. The experience provided in this study can be useful lessons for further improvement of the fuel handling equipment. (authors)

  7. Materials for electrochemical device safety

    Science.gov (United States)

    Vissers, Daniel R.; Amine, Khalil; Thackeray, Michael M.; Kahaian, Arthur J.; Johnson, Christopher S.

    2015-04-07

    An electrochemical device includes a thermally-triggered intumescent material or a gas-triggered intumescent material. Such devices prevent or minimize short circuits in a device that could lead to thermal run-away. Such devices may include batteries or supercapacitors.

  8. Safety lock for radiography exposure device

    International Nuclear Information System (INIS)

    Gaines, T.M.

    1982-01-01

    A safety lock for securing a radiation source in a radiography exposure device is disclosed. The safety lock prevents the inadvertent extension of the radiation source from the exposure device. The exposure devices are used extensively in industry for nondestructive testing of metal materials for defect. Unnecessary exposure of the radiographer or operator occurs not infrequently due to operator's error in believing that the radiation source is secured in the exposure device when, in fact, it is not. The present invention solves this problem of unnecessary exposure by releasingly trapping the radiation source in the shield of the radiography exposure device each time the source is retracted therein so that it is not inadvertently extended therefrom without the operator resetting the safety lock, thereby releasing the radiation source. Further, the safety lock includes an indicator which indicates when the source is trapped in the exposure device and also when it is untrapped. The safety lock is so designed that it does not prevent the return of the source to the trapped, shielded position in the exposure device. Further the safety lock includes a key means for locking the radiation source in the trapped position. The key means cannot be actuated until said radiation source is in said trapped position to further insure the safety lock cannot be inadvertently locked with the source untrapped and thus still extendable from the exposure device

  9. Safety code 19: recommended safety procedures for the selection, installation and use of x-ray diffraction equipment

    International Nuclear Information System (INIS)

    1984-01-01

    This document is one of a series of Safety Codes prepared by the Radiation Protection Bureau to set out requirements for the safe use of radiation emitting devices. The equipment and installation guidelines and safety procedures detailed in this Code are primarily for the instruction and guidance of persons employed in Federal Public Service Departments and Agencies, as well as those coming under the jurisdiction of the Canada Labour Code. This Safety Code is also intended to assist other users of X-ray diffraction equipment to select safe equipment and to install and use it so that the radiation hazard to the operator and other persons in its vicinity is negligible. It should be noted that facilities under provincial jurisdiction may be subject to requirements specified under provincial statutes. This Code supersedes Safety Code RPD-SC-7, entitled 'Requirements For Non-Medical X-Ray Equipment, Use and Installation', insofar as X-ray diffraction equipment is concerned, and it is intended to complement X-ray equipment design, construction and performance standards promulgated under the Radiation Emitting Devices Act

  10. Design review report for modifications to RMCS safety class equipment

    International Nuclear Information System (INIS)

    Corbett, J.E.

    1997-01-01

    This report documents the completion of the formal design review for modifications to the Rotary Mode Core Sampling (RMCS) safety class equipment. These modifications are intended to support core sampling operations in waste tanks requiring flammable gas controls. The objective of this review was to approve the Engineering Change Notices affecting safety class equipment used in the RMCS system. The conclusion reached by the review committee was that these changes are acceptable

  11. Design review report for modifications to RMCS safety class equipment

    Energy Technology Data Exchange (ETDEWEB)

    Corbett, J.E.

    1997-05-30

    This report documents the completion of the formal design review for modifications to the Rotary Mode Core Sampling (RMCS) safety class equipment. These modifications are intended to support core sampling operations in waste tanks requiring flammable gas controls. The objective of this review was to approve the Engineering Change Notices affecting safety class equipment used in the RMCS system. The conclusion reached by the review committee was that these changes are acceptable.

  12. The effect of using road safety equipment and systems and ...

    African Journals Online (AJOL)

    The effect of using road safety equipment and systems and determine their role on ... traffic control equipment situation and by multi-criteria weighting systems AHP ... The results have shown that indices median, lighting and panel type and the ...

  13. Management information system of medical equipment using mobile devices

    Science.gov (United States)

    Núñez, C.; Castro, D.

    2011-09-01

    The large numbers of technologies currently incorporated into mobile devices transform them into excellent tools for capture and to manage the information, because of the increasing computing power and storage that allow to add many miscellaneous applications. In order to obtain benefits of these technologies, in the biomedical engineering field, it was developed a mobile information system for medical equipment management. The central platform for the system it's a mobile phone, which by a connection with a web server, it's capable to send and receive information relative to any medical equipment. Decoding a type of barcodes, known as QR-Codes, the management process is simplified and improved. These barcodes identified the medical equipments in a database, when these codes are photographed and decoded with the mobile device, you can access to relevant information about the medical equipment in question. This Project in it's actual state is a basic support tool for the maintenance of medical equipment. It is also a modern alternative, competitive and economic in the actual market.

  14. Evidence for the safety assurance of the radiation associated equipments for stat-up check

    International Nuclear Information System (INIS)

    Takahashi, Yasuyuki; Igarashi, Hiroshi; Saito, Kyoko; Kawaharada, Yasuhiro; Hirano, Kunihiro; Murase, Kenya; Mochizuki, Teruhito

    2008-01-01

    Based on the new amendment of the Medical Service Law and the Pharmaceutical Affairs Law, the safety control for the medical equipments and devices was strengthened; and a radiological technologist should be stipulated as a safety control manager for the medical equipments and devices. Although it is thought that Start-up check is important for the safety assurance, the enforcement situation is not clear until now. In this report, on the occasion of the start-up of the new Law, questionnaire about the start up check (time and a check items) were investigated from 56 hospitals applying the visit interview. Modality by modality check up time was obtained from 261 institutions by the descriptive study paper type. Start-up check and arming up were applied for almost all modalities about 30 minutes before start of the clinical tests. The check up items for the medical equipments and devices depended on each hospital. Therefore, safety assurance should be established, cooperating with the medical equipment distributors, the hospital sharing the checked results for the patients' safety. (author)

  15. Safety Review related to Commercial Grade Digital Equipment in Safety System

    International Nuclear Information System (INIS)

    Yu, Yeongjin; Park, Hyunshin; Yu, Yeongjin; Lee, Jaeheung

    2013-01-01

    The upgrades or replacement of I and C systems on safety system typically involve digital equipment developed in accordance with non-nuclear standards. However, the use of commercial grade digital equipment could include the vulnerability for software common-mode failure, electromagnetic interference and unanticipated problems. Although guidelines and standards for dedication methods of commercial grade digital equipment are provided, there are some difficulties to apply the methods to commercial grade digital equipment for safety system. This paper focuses on regulatory guidelines and relevant documents for commercial grade digital equipment and presents safety review experiences related to commercial grade digital equipment in safety system. This paper focuses on KINS regulatory guides and relevant documents for dedication of commercial grade digital equipment and presents safety review experiences related to commercial grade digital equipment in safety system. Dedication including critical characteristics is required to use the commercial grade digital equipment on safety system in accordance with KEPIC ENB 6370 and EPRI TR-106439. The dedication process should be controlled in a configuration management process. Appropriate methods, criteria and evaluation result should be provided to verify acceptability of the commercial digital equipment used for safety function

  16. Control of Nuclear Materials and Special Equipment (Nuclear Safety Regulations)

    International Nuclear Information System (INIS)

    Cizmek, A.; Prah, M.; Medakovic, S.; Ilijas, B.

    2008-01-01

    Based on Nuclear Safety Act (OG 173/03) the State Office for Nuclear Safety (SONS) in 2008 adopted beside Ordinance on performing nuclear activities (OG 74/06) and Ordinance on special conditions for individual activities to be performed by expert organizations which perform activities in the area of nuclear safety (OG 74/06) the new Ordinance on the control of nuclear material and special equipment (OG 15/08). Ordinance on the control of nuclear material and special equipment lays down the list of nuclear materials and special equipment as well as of nuclear activities covered by the system of control of production of special equipment and non-nuclear material, the procedure for notifying the intention to and filing the application for a license to carry out nuclear activities, and the format and contents of the forms for doing so. This Ordinance also lays down the manner in which nuclear material records have to be kept, the procedure for notifying the State administration organization (regulatory body) responsible for nuclear safety by the nuclear material user, and the keeping of registers of nuclear activities, nuclear material and special equipment by the State administration organization (regulatory body) responsible for nuclear safety, as well as the form and content of official nuclear safety inspector identification card and badge.(author)

  17. Nuclear power plants. Electrical equipment of the safety system. Qualification

    International Nuclear Information System (INIS)

    2001-01-01

    This International Standard applies to electrical parts of safety systems employed at nuclear power plants, including components and equipment of any interface whose failure could affect unfavourably properties of the safety system. The standard also applies to non-electrical safety-related interfaces. Furthermore, the standard describes the generic process of qualification certification procedures and methods of qualification testing and related documentation. (P.A.)

  18. Monitoring Device Safety in Interventional Cardiology

    OpenAIRE

    Matheny, Michael E.; Ohno-Machado, Lucila; Resnic, Frederic S.

    2006-01-01

    Objective: A variety of postmarketing surveillance strategies to monitor the safety of medical devices have been supported by the U.S. Food and Drug Administration, but there are few systems to automate surveillance. Our objective was to develop a system to perform real-time monitoring of safety data using a variety of process control techniques.

  19. Nuclear reactor core safety device

    International Nuclear Information System (INIS)

    Colgate, S.A.

    1977-01-01

    The danger of a steam explosion from a nuclear reactor core melt-down can be greatly reduced by adding a gasifying agent to the fuel that releases a large amount of gas at a predetermined pre-melt-down temperature that ruptures the bottom end of the fuel rod and blows the finely divided fuel into a residual coolant bath at the bottom of the reactor. This residual bath should be equipped with a secondary cooling loop

  20. Nuclear reactor safety protection device

    International Nuclear Information System (INIS)

    Okido, Fumiyasu; Noguchi, Atomi; Matsumiya, Shoichi; Furusato, Ken-ichiro; Arita, Setsuo.

    1994-01-01

    The device of the present invention extremely reduces a probability of causing unnecessary scram of a nuclear reactor. That is, four control devices receive signals from each of four sensors and output four trip signals respectively in a quardruplicated control device. Each of the trip signals and each of trip signals via a delay circuit are inputted to a logical sum element. The output of the logical sum circuit is inputted to a decision of majority circuit. The decision of majority circuit controls a scram pilot valve which conducts scram of the reactor by way of a solenoid coils. With such procedures, even if surge noises of a short pulse width are mixed to the sensor signals and short trip signals are outputted, there is no worry that the scram pilot valve is actuated. Accordingly, factors of lowering nuclear plant operation efficiency due to erroneous reactor scram can be reduced. (I.S.)

  1. [Implementation of safety devices: biological accident prevention].

    Science.gov (United States)

    Catalán Gómez, M Teresa; Sol Vidiella, Josep; Castellà Castellà, Manel; Castells Bo, Carolina; Losada Pla, Nuria; Espuny, Javier Lluís

    2010-04-01

    Accidental exposures to blood and biological material were the most frequent and potentially serious accidents in healthcare workers, reported in the Prevention of Occupational Risks Unit within 2002. Evaluate the biological percutaneous accidents decrease after a progressive introduction of safety devices. Biological accidents produced between 2.002 and 2.006 were analyzed and reported by the injured healthcare workers to the Level 2b Hospital Prevention of Occupational Risk Unit with 238 beds and 750 employees. The key of the study was the safety devices (peripheral i.v. catheter, needleless i.v. access device and capillary blood collection lancet). Within 2002, 54 percutaneous biological accidents were registered and 19 in 2006, that represents a 64.8% decreased. There has been no safety devices accident reported involving these material. Accidents registered during the implantation period occurred because safety devices were not used at that time. Safety devices have proven to be effective in reducing needle stick percutaneous accidents, so that they are a good choice in the primary prevention of biological accidents contact.

  2. Inquiry about the uses of special equipment (CT equipment, angiography systems, mammography devices, screens)

    International Nuclear Information System (INIS)

    Schwager, P.; Stieve, F.E.

    1986-01-01

    There are at least 1100 special devices in medical establishment in Bavaria which require special inspection and surveillance with regard to quality of equipment and radiation protection. In addition, there are at least 53 tomographs available for operation, and at least 120 installed X-ray screens. These devices need special approval testing and quality control services as they contribute a very significant amount of the medically indicated radiation exposure of the population. Appropriate measures are explained that can be applied in order to reduce the medical radiation exposure to an optimum. (orig.) [de

  3. Nuclear safety regulation on nuclear safety equipment activities in relation to human and organizational factors

    International Nuclear Information System (INIS)

    Li Tianshu

    2013-01-01

    Based on years of knowledge in nuclear safety supervision and experience of investigating and dealing with violation events in repair welding of DFHM, this paper analyzes major faults in manufacturing and maintaining activities of nuclear safety equipment in relation to human and organizational factors. It could be deducted that human and organizational factors has definitely become key features in the development of nuclear energy and technology. Some feasible measures to reinforce supervision on nuclear safety equipment activities have also been proposed. (author)

  4. Guidelines for nuclear reactor equipments safety-analysis

    International Nuclear Information System (INIS)

    1978-01-01

    The safety analysis in approving the applications for nuclear reactor constructions (or alterations) is performed by the Committee on Examination of Reactor Safety in accordance with various guidelines prescribed by the Atomic Energy Commission. In addition, the above Committee set forth its own regulations for the safety analysis on common problems among various types of nuclear reactors. This book has collected and edited those guidelines and regulations. It has two parts: Part I includes the guidelines issued to date by the Atomic Energy Commission: and Part II - regulations of the Committee. Part I has collected 8 categories of guidelines which relate to following matters: nuclear reactor sites analysis guidelines and standards for their applications; standard exposure dose of plutonium; nuclear ship operation guidelines; safety design analysis guidelines for light-water type, electricity generating nuclear reactor equipments; safety evaluation guidelines for emergency reactor core cooling system of light-water type power reactors; guidelines for exposure dose target values around light-water type electricity generating nuclear reactor equipments, and guidelines for evaluation of above target values; and meteorological guidelines for the safety analysis of electricity generating nuclear reactor equipments. Part II includes regulations of the Committee concerning - the fuel assembly used in boiling-water type and in pressurized-water type reactors; techniques of reactor core heat designs, etc. in boiling-water reactors; and others

  5. Auxetic foam for snowsport safety devices

    OpenAIRE

    Allen, Tom; Duncan, Olly; Foster, Leon; Senior, Terry; Zampieri, Davide; Edeh, Victor; Alderson, Andrew

    2017-01-01

    Skiing and snowboarding are popular snow-sports with inherent risk of injury. There is potential to reduce the prevalence of injuries by improving and implementing snow-sport safety devices with the application of advanced materials. This paper investigates the application of auxetic foam to snow-sport safety devices. Composite pads - consisting of foam covered with a semi-rigid shell - were investigated as a simple model of body armour and a large 70 x 355 x 355 mm auxetic foam sample was fa...

  6. NIF special equipment construction health and safety plan

    Energy Technology Data Exchange (ETDEWEB)

    Sawicki, R.H.

    1997-07-28

    The purpose of this plan is to identify how the construction and deployment activities of the National Ignition Facility (NIF) Special Equipment (SE) will be safely executed. This plan includes an identification of (1) the safety-related responsibilities of the SE people and their interaction with other organizations involved; (2) safety related requirements, policies, and documentation; (3) a list of the potential hazards unique to SE systems and the mechanisms that will be implemented to control them to acceptable levels; (4) a summary of Environmental Safety and Health (ES&H) training requirements; and (5) requirements of contractor safety plans that will be developed and used by all SE contractors participating in site activities. This plan is a subsidiary document to the NIF Construction Safety Program (CSP) and is intended to compliment the requirements stated therein with additional details specific to the safety needs of the SE construction-related activities. If a conflict arises between these two documents, the CSP will supersede. It is important to note that this plan does not list all of the potential hazards and their controls because the design and safety analysis process is still ongoing. Additional safety issues win be addressed in the Final Safety Analysis Report, Operational Safety Procedures (OSPs), and other plans and procedures as described in Section 3.0 of this plan.

  7. NIF special equipment construction health and safety plan

    International Nuclear Information System (INIS)

    Sawicki, R.H.

    1997-01-01

    The purpose of this plan is to identify how the construction and deployment activities of the National Ignition Facility (NIF) Special Equipment (SE) will be safely executed. This plan includes an identification of (1) the safety-related responsibilities of the SE people and their interaction with other organizations involved; (2) safety related requirements, policies, and documentation; (3) a list of the potential hazards unique to SE systems and the mechanisms that will be implemented to control them to acceptable levels; (4) a summary of Environmental Safety and Health (ES ampersand H) training requirements; and (5) requirements of contractor safety plans that will be developed and used by all SE contractors participating in site activities. This plan is a subsidiary document to the NIF Construction Safety Program (CSP) and is intended to compliment the requirements stated therein with additional details specific to the safety needs of the SE construction-related activities. If a conflict arises between these two documents, the CSP will supersede. It is important to note that this plan does not list all of the potential hazards and their controls because the design and safety analysis process is still ongoing. Additional safety issues win be addressed in the Final Safety Analysis Report, Operational Safety Procedures (OSPs), and other plans and procedures as described in Section 3.0 of this plan

  8. Regulatory Activities on Civil Nuclear Safety Equipment in China

    International Nuclear Information System (INIS)

    Gaoshang, Lu; Choi, Kwang Sik

    2011-01-01

    It is stipulated in IAEA Fundamental Safety Principles (SF1) that the fundamental safety objective is to protect people and the environment from harmful effects of ionizing radiation. The fundamental safety objective applies for all facilities and activities and for all stages over the lifetime of a facility or radiation source, including planning, sitting, design, manufacturing, construction, commissioning and operation, as well as decommissioning and closure. So, according to the requirement, the related activities such as design, manufacturing, installation and non-destructive test that conducted on civil nuclear equipment should be well controlled by the vendors, the owner of the nuclear power plants and the regulatory body. To insure the quality of those equipment, Chinese government had taken a series of measures to regulate the related activities on them

  9. Stakeholder challenges in purchasing medical devices for patient safety.

    Science.gov (United States)

    Hinrichs, Saba; Dickerson, Terry; Clarkson, John

    2013-03-01

    This study identifies the stakeholders who have a role in medical device purchasing within the wider system of health-care delivery and reports on their particular challenges to promote patient safety during purchasing decisions. Data was collected through observational work, participatory workshops, and semi-structured qualitative interviews, which were analyzed and coded. The study takes a systems-based and engineering design approach to the study. Five hospitals took part in this study, and the participants included maintenance, training, clinical end-users, finance, and risk departments. The main stakeholders for purchasing were identified to be staff from clinical engineering (Maintenance), device users (Clinical), device trainers (Training), and clinical governance for analyzing incidents involving devices (Risk). These stakeholders display varied characteristics in terms of interpretation of their own roles, competencies for selecting devices, awareness and use of resources for purchasing devices, and attitudes toward the purchasing process. The role of "clinical engineering" is seen by these stakeholders to be critical in mediating between training, technical, and financial stakeholders but not always recognized in practice. The findings show that many device purchasing decisions are tackled in isolation, which is not optimal for decisions requiring knowledge that is currently distributed among different people within different departments. The challenges expressed relate to the wider system of care and equipment management, calling for a more systemic view of purchasing for medical devices.

  10. Radiation safety of sealed sources and equipment containing them

    International Nuclear Information System (INIS)

    1993-01-01

    The guide gives information and requirements concerning the technical construction, installation, use and licensing of devices containing sealed radioactive sources in order to ensure the operational safety. The requirements are in accordance with the international standards ISO 1677, ISO 2919, ISO 7205 and Nordic Recommendations on radiation protection for radionuclide gauges in permanent installation. The guide explains also the practical measures that must be taken into account when a radiation device is repaired, maintained or removed from the use. (8 refs.)

  11. Standardization and improvement of safety for radioisotope equipped instruments

    International Nuclear Information System (INIS)

    Sumi, Tetsuo

    1980-01-01

    The safety for radioisotope-equipped instruments is considered. The one is the safety for the source assembly. The radioisotopes employed for radioisotope-equipped instruments are sealed sources which are used in the state of being contained in the enclosures. Many of the enclosures are provided with shutter mechanism for the purpose of emitting radiation only during the period required. If the possible troubles that might lead to the accidents are sampled out of the results of field operation of radiation instruments, and the safety measures for source enclosures are considered in connection with these troubles, it is no exaggeration to say that the safety for source enclosures has been maintained by preventing the critical accidents by the management of users and the cooperation of manufactures though there were the chance for investigating the safety in the common field and the establishment of JIS Z 4614 standard. Another consideration is concerned with the measures to improve the safety. No accident in the past never guarantees no accident in the future. Accumulation of experience is most effective for those measures, and the more experiences the better. It may be most effective that the manufacturers disclose their experiences each other from the wide outlook overcoming the barrier of trade secret. Fortunately, such consciousness has risen since a few years ago, and the investigation group is doing the works in the Japan Radioisotope Association. On the other hand, the reasonable revision of the radiation injury prevention law is desired. (Wakatsuki, Y.)

  12. Discussion on unpacking inspection of imported civil nuclear safety equipment

    International Nuclear Information System (INIS)

    Li Chan; Zhang Wenguang; Li Maolin; Li Shixin; Jin Gang; Yao Yuan

    2014-01-01

    This paper introduces the purpose, contents, process and requirements of unpacking inspection which is the second stage of safety inspection of imported civil nuclear safety equipment, expresses review key points on application documents of unpacking inspection, processes of witness on-the-spot before unpacking inspection outside the civil nuclear facilities by the test agency, discusses understanding of unpacking inspection, supervision of manufacture, inspection prior to shipment, supervision of loading and acceptance by the unit operating civil nuclear facilities, reports on unpacking inspection. Some suggestions on reinforcing the unpacking inspection in China are concerned. (authors)

  13. Comparison of safety equipment between London underground and Beijing subway

    Science.gov (United States)

    Chen, T.; Zhang, S. Y.; Zhao, L. Z.; Xia, J. J.; Fu, X. C.; Bao, Z. M.; Chen, Y.; Zhang, X. Z.; Wang, R. J.; Hu, C.; Jing, L. S.; Wang, Y.

    2017-06-01

    The purpose of this paper was to improve the safety equipment’s effectiveness through the comparison. Firstly, the history and safety accident of London Underground and Beijing Subway were shown. Secondly, fire equipment between these two cities was compared including station’s hardware installations and carriage’s hardware installations. Thirdly, the relative software installations were also compared such as emergency drills. The results showed that Beijing Subway’s hardware installations were better than London. However, London Underground’s some installations were more effective than Beijing. Both cities would pay more attention on anti-terrorist in tunnel.

  14. Aspects of safety assessments for package with additional equipment components

    International Nuclear Information System (INIS)

    Reiche, I.; Boerst, F.M.; Krietsch, T.

    2004-01-01

    Many paragraphs in TS-R-1 contain the terms ''package'' or ''packaging''. These terms are defined in TS-R-1 paras 230 and 231 and explained in TS-G-1.1 paras 230.1 - 230.6. The importance of a consistent understanding of these definitions has been shown by recent discussions during the assessment of applications for package design approval. There was disagreement, if equipment components attached to the container body during transport, e.g. a transport frame, should be considered part of the package and taken into account in the safety assessment for the package. Discussions were also caused by the way inner design components are treated in the safety assessment of the package. This paper summarises the regulatory requirements to such additional equipment components and presents the way of their inclusion into the package design approval process in Germany

  15. 30 CFR 250.806 - Safety and pollution prevention equipment quality assurance requirements.

    Science.gov (United States)

    2010-07-01

    ... 30 Mineral Resources 2 2010-07-01 2010-07-01 false Safety and pollution prevention equipment... Gas Production Safety Systems § 250.806 Safety and pollution prevention equipment quality assurance... install only certified safety and pollution prevention equipment (SPPE) in wells located on the OCS. SPPE...

  16. Technical evaluation of seismic qualification of safety-related equipment

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yang Hui; Park, Heong Gee; Park, Yeong Seok [Univ. of Incheon, Incheon (Korea, Republic of)

    1994-04-15

    This study is purposed to evaluate the technical acceptability of the procedures and techniques of seismic qualifications which were performed for the YGN 3 and 4 safety-related equipment.This study is also targeted to suggest a systematized technical procedure guide for the effective performance and review of the seismic qualification, which reflects the most up-to-date licensing requirements and state-of the-art.

  17. Safety for Compressed Gas and Air Equipment. Module SH-26. Safety and Health.

    Science.gov (United States)

    Center for Occupational Research and Development, Inc., Waco, TX.

    This student module on safety for compressed gas and air equipment is one of 50 modules concerned with job safety and health. This module presents technical data about commonly used gases and stresses the procedures necessary for safe handling of compressed gases. Following the introduction, 14 objectives (each keyed to a page in the text) the…

  18. Software used to size the safety devices

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    To avoid mistakes during the calculation, CEA/SBT has decided to write a software that take into account all the situations it is possible to encountered (subcritical state, supercritical state, …). The goal is to permit to the engineer in charge of a cryostat manufacturing to perform this calculation; he is the only person able to do the accidental analysis which is fundamental for the sizing of the safety device. The software performed will be presented.

  19. Autonomous booster device of a safety valve

    International Nuclear Information System (INIS)

    Namand, H.

    1983-01-01

    The invention concerns an autonomous booster device of a protection safety valve of a pressure vessel. The valve comprises a hollow structure, a seat connected with a mobile flap forming one piece with a stem and a calibration spring bearing on the stem and on the valve structure to maintain the flap bearing on the seat. The stem of the flap is prolongated in a box forming one piece with the valve structure and receives an added push of a spring. The box acts as a pressure device of which the piston can exercise on the stem a push opposite to and larger than the spring one. The feeding device of the pressure box is finally described in detail [fr

  20. Method of operator safety assessment for underground mobile mining equipment

    Science.gov (United States)

    Działak, Paulina; Karliński, Jacek; Rusiński, Eugeniusz

    2018-01-01

    The paper presents a method of assessing the safety of operators of mobile mining equipment (MME), which is adapted to current and future geological and mining conditions. The authors focused on underground mines, with special consideration of copper mines (KGHM). As extraction reaches into deeper layers of the deposit it can activate natural hazards, which, thus far, have been considered unusual and whose range and intensity are different depending on the field of operation. One of the main hazards that affect work safety and can become the main barrier in the exploitation of deposits at greater depths is climate threat. The authors have analysed the phenomena which may impact the safety of MME operators, with consideration of accidents that have not yet been studied and are not covered by the current safety standards for this group of miners. An attempt was made to develop a method for assessing the safety of MME operators, which takes into account the mentioned natural hazards and which is adapted to current and future environmental conditions in underground mines.

  1. Method of operator safety assessment for underground mobile mining equipment

    Directory of Open Access Journals (Sweden)

    Działak Paulina

    2018-01-01

    Full Text Available The paper presents a method of assessing the safety of operators of mobile mining equipment (MME, which is adapted to current and future geological and mining conditions. The authors focused on underground mines, with special consideration of copper mines (KGHM. As extraction reaches into deeper layers of the deposit it can activate natural hazards, which, thus far, have been considered unusual and whose range and intensity are different depending on the field of operation. One of the main hazards that affect work safety and can become the main barrier in the exploitation of deposits at greater depths is climate threat. The authors have analysed the phenomena which may impact the safety of MME operators, with consideration of accidents that have not yet been studied and are not covered by the current safety standards for this group of miners. An attempt was made to develop a method for assessing the safety of MME operators, which takes into account the mentioned natural hazards and which is adapted to current and future environmental conditions in underground mines.

  2. Quality and safety based management of radiological and clinical equipment

    International Nuclear Information System (INIS)

    Arora, S.; Saini, P.S.

    2001-01-01

    TQM (Total quality management) is the 'buzz' acronym expected in almost every aspect of industrial manufacturing, product development and services solicited by the outside agencies. The correct management of the many technological resources in health institutions in terms of efficiency, effectiveness and safety is a necessity in view of the criteria on which modern medicine is based. Almost all activities -be they diagnostic, therapeutic and rehabilitative - carried out within a modern hospital are based on widespread application of equipment and technology, the efficiency of which can directly influence the quality of service offered to the patient

  3. Co-operation Equipment Qualification for Safety grade I and C Equipment between Russia and Korea

    International Nuclear Information System (INIS)

    Ham, J. K.; Lee, D. H.; Park, J. W.; Jeong, M. H.; Choi, Y. H.; Suh, J. J.; Jang, T. H.

    2007-06-01

    Equipment Qualification technology for I and C system on nuclear grade have been approved with accurate and safe for verifying and validation. It contributes to acknowledge of reliability and to review of user approval. Also it did not completely satisfied the requirement of Russia, it can be satisfied by bit of modification on design. It is expected to support the export of safety PLC to nuclear power plant. Proven EQ technology is required on the further markets of nuclear. Therefore, comparison test with foreign country is necessary to support the mutual accreditation of EQ for export of domestic products

  4. Co-operation Equipment Qualification for Safety grade I and C Equipment between Russia and Korea

    Energy Technology Data Exchange (ETDEWEB)

    Ham, J. K.; Lee, D. H.; Park, J. W.; Jeong, M. H.; Choi, Y. H.; Suh, J. J.; Jang, T. H. [Korea Testing Laboratory, Seoul (Korea, Republic of)

    2007-06-15

    Equipment Qualification technology for I and C system on nuclear grade have been approved with accurate and safe for verifying and validation. It contributes to acknowledge of reliability and to review of user approval. Also it did not completely satisfied the requirement of Russia, it can be satisfied by bit of modification on design. It is expected to support the export of safety PLC to nuclear power plant. Proven EQ technology is required on the further markets of nuclear. Therefore, comparison test with foreign country is necessary to support the mutual accreditation of EQ for export of domestic products.

  5. Safety equipment and methods for evaluating its effectiveness

    Energy Technology Data Exchange (ETDEWEB)

    Evdokimov, F I; Nadtoka, T B [DPI (Ukraine)

    1993-05-01

    Analyzes relations between technologies (especially for roof support) used in black coal mining and work safety in mines. The share of manual work and accident rate are compared for mining by narrow and wide web shearer loaders and by coal plows with powered and individual support. Protection from occupational injury is discussed at three levels: safety engineering, work organization and the human factor. A method of evaluating the social and economic effectiveness of protection from occupational injury developed at the DPI institute is presented. The method uses the knowledge of probability distribution of failure situations, failures and protective means to determine the probabilistic characteristics of the functioning of protection systems and to calculate, for a given period, the occurrence probability and mean number of accidents. Each state of the system is characterized by determined social and/or economic results. The method was used in designing equipment intended for protective power cut-off in electric mine networks.

  6. Configuration control during maintenance of safety related equipment

    International Nuclear Information System (INIS)

    Irish, C.S.

    2001-01-01

    Possibly the most important aspect of performing maintenance of safety related equipment is maintaining the component's original design basis. Assuring that the repaired item will perform the same safety function within the original performance and equipment qualification parameters is commonly referred to as configuration control. Maintaining configuration control of a technologically current well documented item is easy. Unfortunately, this does not describe most safety related items requiring maintenance within the global nuclear industry. Items such as motors, transformers, metal clad switchgear (low and medium voltage circuit breakers), refrigeration compressors, and electronic components (i.e. circuit boards, power supplies, regulators, etc.) which routinely require repair have been in service for twenty plus years. As a result, finding replacement parts and or material to repair the items to the original condition is becoming more and more difficult. An added difficulty is the lack of original technical documentation available on the item which is being repaired. The lack of technical documentation makes it difficult to identify replacement material and parts when the original part or material is not available. The lack of documentation also makes it difficult to test the repaired item to make sure that the original configuration has been maintained after the repair. The presentation will discuss the details of repairing various items including motors, metal clad switchgear, refrigeration compressors and power supplies and the controls which are necessary to maintain the configuration of the original item. The discussion will include the Quality Assurance and engineering necessary to identify and evaluate replacement material and parts necessary to perform repairs on safety related equipment when the original material or part is not available. Examples of repairs which required different parts or materials than the original to be used in the repair will be

  7. Configuration control during maintenance of safety related equipment

    International Nuclear Information System (INIS)

    Irish, C.S.

    2003-01-01

    Possibly the most important aspect of performing maintenance of safety related equipment is maintaining the component's original design basis. Assuring that the repaired item will perform the same safety function within the original performance and equipment qualification parameters is commonly referred to as configuration control. Maintaining configuration control of a technologically current well documented item is easy. Unfortunately, this does not describe most safety related items requiring maintenance within the global nuclear industry. Items such as motors, transformers, metal clad switchgear (low and medium voltage circuit breakers), refrigeration compressors, and electronic components (i.e. circuit boards, power supplies, regulators, etc.) which routinely require repair have been in service for twenty plus years. As a result, finding replacement parts and or material to repair the items to the original condition is becoming more and more difficult. An added difficulty is the lack of original technical documentation available on the item which is being repaired. The lack of technical documentation makes it difficult to identify replacement material and parts when the original part or material is not available. The lack of documentation also makes it difficult to test the repaired item to make sure that the original configuration has been maintained after the repair. The presentation will discuss the details of repairing various items including motors, metal clad switchgear, refrigeration compressors and power supplies and the controls which are necessary to maintain the configuration of the original item. The discussion will include the Quality Assurance and engineering necessary to identify and evaluate replacement material and parts necessary to perform repairs on safety related equipment when the original material or part is not available. Examples of repairs which required different parts or materials than the original to be used in the repair will be

  8. Material & equipment, procurement & maintenance: Impact on blood safety.

    Science.gov (United States)

    Emmanuel, Jean C

    2010-01-01

    Blood Transfusion Safety is dependent on effectively organised and managed blood services, which have adequate financial resources, skilled manpower, appropriate infrastructure and quality management systems in place. 80% of the world's population has access to 20% of the supply blood products, of which little is consistently safe. HIV highlighted the importance of blood safety. The lack of effective blood services in low human development index (LHDI), developing countries, has lead to international funding and capacity building for more than three decades. The initial strategies focused on providing HIV testing reagents to prevention transmission, however this only addresses one part of blood safety. Blood safety is not only dependent on preventing HIV transmission. In many populations there are other infectious agents, which have a higher prevalence. Ensuring the correct blood is provided to the patient depends on: well managed services with effective leadership and adequate budgets; capacity building and retention of skilled experienced staff; availability of laboratory equipment, correctly maintained; blood cold chain systems; procedures for tendering, purchasing and ensuring an unbroken supply of reagents and consumables; and quality management systems. Barriers for simplified effective tendering, procurement and contracting require urgent attention and coordination of all funding organisations to ensure an unbroken supply of reagents. Copyright 2009. Published by Elsevier Ltd.

  9. A Study on Performance and Safety Tests of Electrosurgical Equipment.

    Science.gov (United States)

    Tavakoli Golpaygani, A; Movahedi, M M; Reza, M

    2016-09-01

    Modern medicine employs a wide variety of instruments with different physiological effects and measurements. Periodic verifications are routinely used in legal metrology for industrial measuring instruments. The correct operation of electrosurgical generators is essential to ensure patient's safety and management of the risks associated with the use of high and low frequency electrical currents on human body. The metrological reliability of 20 electrosurgical equipment in six hospitals (3 private and 3 public) was evaluated in one of the provinces of Iran according to international and national standards. The achieved results show that HF leakage current of ground-referenced generators are more than isolated generators and the power analysis of only eight units delivered acceptable output values and the precision in the output power measurements was low. Results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially in high risk instruments. It is also necessary to provide training courses for operating staff in the field of meterology in medicine to be acquianted with critical parameters to get accuracy results with operation room equipment.

  10. A Study on Performance and Safety Tests of Electrosurgical Equipment

    Directory of Open Access Journals (Sweden)

    Tavakoli Golpaygani A.

    2016-09-01

    Full Text Available Introduction: Modern medicine employs a wide variety of instruments with different physiological effects and measurements. Periodic verifications are routinely used in legal metrology for industrial measuring instruments. The correct operation of electrosurgical generators is essential to ensure patient’s safety and management of the risks associated with the use of high and low frequency electrical currents on human body. Material and Methods: The metrological reliability of 20 electrosurgical equipment in six hospitals (3 private and 3 public was evaluated in one of the provinces of Iran according to international and national standards. Results: The achieved results show that HF leakage current of ground-referenced generators are more than isolated generators and the power analysis of only eight units delivered acceptable output values and the precision in the output power measurements was low. Conclusion: Results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially in high risk instruments. It is also necessary to provide training courses for operating staff in the field of meterology in medicine to be acquianted with critical parameters to get accuracy results with operation room equipment.

  11. Considerations concerning the reliability of reactor safety equipment

    International Nuclear Information System (INIS)

    Furet, J.; Guyot, Ch.

    1967-01-01

    A review is made of the circumstances which favor a good collection of maintenance data at the C.E.A. The large amount of data to be treated has made necessary the use of a computer for analyzing automatically the results collected. Here, only particular aspects of the reliability from the point of view of the electronics used for nuclear reactor control will be dealt with: sale and unsafe failures; probability of survival (in the case of reactor safety); availability. The general diagrams of the safety assemblies which have been drawn up for two types of reactor (power reactor and low power experimental reactor) are given. Results are presented of reliability analysis which could be applied to the use of functional modular elements, developed industrially in France. Improvement of this reliability appears to be fairly limited by an increase in the redundancy; on the other hand it is shown how it may be very markedly improved by the use of automatic tests with different frequencies for detecting unsafe failures rates of measurements for the sub-assemblies and for the logic sub-assemblies. Finally examples are given to show the incidence of the complexity and of the use of different technologies in reactor safety equipment on the reliability. (authors) [fr

  12. Evaluation of safety requirements of erbium laser equipment used in dentistry

    International Nuclear Information System (INIS)

    Braga, Flavio Hamilton

    2002-01-01

    The erbium laser (Er:YAG) has been used in several therapeutic processes. Erbium lasers, however, operate with energies capable to produce lesions in biological tissues. Aiming the safe use, the commercialization of therapeutic laser equipment is controlled in Brazil, where the equipment should comply with quality and safety requirement prescribed in technical regulations. The objective of this work is to evaluate the quality and safety requirements of a commercial therapeutic erbium laser according to Brazilian regulations, and to discuss a risk control program intended to minimize the accidental exposition at dangerous laser radiation levels. It was verified that the analyzed laser can produce lesions in the skin and eyes, when exposed to laser radiation at distances smaller than 80 cm by 10 s or more. In these conditions, the use of protection glasses is recommended to the personnel that have access to the laser operation ambient. It was verified that the user's training and the presence of a target indicator are fundamental to avoid damages in the skin and buccal cavity. It was also verified that the knowledge and the correct use of the equipment safety devices, and the application of technical and administrative measures is efficient to minimize the risk of dangerous expositions to the laser radiation. (author)

  13. A preliminary design of mechanical device on industrial digital radiography equipment design

    International Nuclear Information System (INIS)

    Nur Khasan; Samuel Praptoyo

    2015-01-01

    A preliminary design of mechanical device on industrial digital radiography equipment has been done. this design is intended as a basis for the manufacture of complete facilities for the realization a prototype on industrial digital radiography equipment. the design and construction were carried out by paying attention to the general configuration of the basic design in which its mechanical design has several components with specific dimensions and heavy mass. this design consist of a main frame holder, flat panel detector support and hydraulic hand stacker for mounting the x-ray machine. this mechanical device design will then be fabricated to facilitate and assist work of digital radiographic retrieval. computer application programs sketch-up is used to draw this design and the analysis stress of autodesk inventor to analysis the strength construction design. the results of this design are the configuration drawing, sketch drawings of construction and the safety factor of construction design with a minimum value of 2.39 as well as a maximum value of 15 when to be simulated by the load 500 Kg which is 4 times of total workload. (author)

  14. Industrial high pressure applications. Processes, equipment and safety

    Energy Technology Data Exchange (ETDEWEB)

    Eggers, Rudolf (ed.) [Technische Univ. Hamburg-Harburg, Hamburg (Germany). Inst. fuer Thermische Verfahrenstechnik

    2012-07-01

    Industrial high pressure processes open the door to many reactions that are not possible under 'normal' conditions. These are to be found in such different areas as polymerization, catalytic reactions, separations, oil and gas recovery, food processing, biocatalysis and more. The most famous high pressure process is the so-called Haber-Bosch process used for fertilizers and which was awarded a Nobel prize. Following an introduction on historical development, the current state, and future trends, this timely and comprehensive publication goes on to describe different industrial processes, including methanol and other catalytic syntheses, polymerization and renewable energy processes, before covering safety and equipment issues. With its excellent choice of industrial contributions, this handbook offers high quality information not found elsewhere, making it invaluable reading for a broad and interdisciplinary audience.

  15. Nuclear safety: a large scale quality audit of pressurized equipment

    International Nuclear Information System (INIS)

    Faudon, Valerie

    2016-01-01

    This article notably refers to, quotes and comments a hearing organised by the French Public Office for the Assessment Scientific and Technological Choices (OPECST) on the issue of safety of pressurized equipment in nuclear reactors, and which gathered the main concerned actors (Areva, EDF, IRSN, ASN) to have an overview of quality controls in AREVA NP fabrication plants. Two different issues have been addressed: a technical metallurgical issue related to some boiler-making parts, and an issue related to quality assurance. These issues concern different older reactors (Fessenheim for example) as well as new ones (EPR Flamanville). The article indicates the different measures planned, envisaged or already implemented by the concerned actors in order to improve knowledge in the boiler-making industry, and to ensure a better quality

  16. 33 CFR 159.131 - Safety: Incinerating device.

    Science.gov (United States)

    2010-07-01

    ... (CONTINUED) POLLUTION MARINE SANITATION DEVICES Design, Construction, and Testing § 159.131 Safety.... Unitized incineration devices must completely burn to a dry, inert ash, a simultaneous defecation and...

  17. 46 CFR 189.60-10 - Cargo Ship Safety Equipment Certificate.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 7 2010-10-01 2010-10-01 false Cargo Ship Safety Equipment Certificate. 189.60-10... VESSELS INSPECTION AND CERTIFICATION Certificates Under International Convention for Safety of Life at Sea, 1974 § 189.60-10 Cargo Ship Safety Equipment Certificate. (a) All vessels on an international voyage...

  18. 46 CFR 91.60-10 - Cargo Ship Safety Equipment Certificate.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 4 2010-10-01 2010-10-01 false Cargo Ship Safety Equipment Certificate. 91.60-10... VESSELS INSPECTION AND CERTIFICATION Certificates Under International Convention for Safety of Life at Sea, 1974 § 91.60-10 Cargo Ship Safety Equipment Certificate. (a) All vessels on an international voyage are...

  19. 38 CFR 17.155 - Minimum standards of safety and quality for automotive adaptive equipment.

    Science.gov (United States)

    2010-07-01

    ... safety and quality for automotive adaptive equipment. 17.155 Section 17.155 Pensions, Bonuses, and... Minimum standards of safety and quality for automotive adaptive equipment. (a) The Under Secretary for... officials that it meets implicit standards of safety and quality adopted by the industry or as later...

  20. Safety equipment list for the light duty utility arm system

    International Nuclear Information System (INIS)

    Barnes, G.A.

    1998-01-01

    The initial issue (Revision 0) of this Safety Equipment List (SEL) for the Light Duty Utility Arm (LDUA) requires an explanation for both its existence and its being what it is. All LDUA documentation leading up to creation of this SEL, and the SEL itself, is predicated on the LDUA only being approved for use in waste tanks designated as Facility Group 3, i.e., it is not approved for use in Facility Group 1 or 2 waste tanks. Facility Group 3 tanks are those in which a spontaneous or induced hydrogen gas release would be small, localized, and would not exceed 25% of the LFL when mixed with the remaining air volume in the dome space; exceeding these parameters is considered unlikely. Thus, from a NFPA flammable gas environment perspective the waste tank interior is not classified as a hazardous location. Furthermore, a hazards identification and evaluation (HNF-SD-WM-HIE-010, REV 0) performed for the LDUA system concluded that the consequences of actual LDUA system postulated accidents in Flammable Gas Facility Group 3 waste tanks would have either NO IMPACT or LOW IMPACT on the offsite public and onsite worker. Therefore, from a flammable gas perspective, there is not a rationale for classifying any of SSCs associated with the LDUA as either Safety Class (SC) or Safety Significant (SS) SSCs, which, by default, categorizes them as General Service (GS) SSCs. It follows then, based on current PHMC procedures (HNF-PRO-704 and HNF-IP-0842, Vol IV, Section 5.2) for SEL creation and content, and from a flammable gas perspective, that an SEL is NOT REQ at sign D HOWEVER exclamation point exclamation point exclamation point There is both a precedent and a prudency to capture all SSCS, which although GS, contribute to a Defense-In-Depth (DID) approach to the design and use of equipment in potentially flammable gas environments. This Revision 0 of the LDUA SEL has been created to capture these SSCs and they are designated as GS-DID in this document. The specific reasons for

  1. The Role of Patient Safety in the Device Purchasing Process

    National Research Council Canada - National Science Library

    Johnson, Todd R; Zhang, Jiajie; Patel, Vimla L; Keselman, Alla; Tang, Xiaozhou; Brixey, Juliana J; Paige, Danielle; Turley, James P

    2005-01-01

    To examine how patient safety considerations are incorporated into medical device purchase decisions, individuals involved in recent infusion pump purchasing decisions at three different health care...

  2. Safety equipment list for 241-C-106 waste retrieval, Project W-320: Revision 1

    International Nuclear Information System (INIS)

    Conner, J.C.

    1994-01-01

    The goals of the C-106 sluicing operation are: (1) to stabilize the tank by reducing the heat load in the tank to less than 42 MJ/hr (40,000 Btu/hour), and (2) to initiate demonstration of single-shell tank (SST) retrieval technology. The purpose of this supporting document (SD) is as follows: (1) to provide safety classifications for items (systems, structures, equipment, components, or parts) for the waste retrieval sluicing system (WRSS), and (2) to document and methodology used to develop safety classifications. Appropriate references are made with regard to use of existing systems, structures, equipments, components, and parts for C-106 single-shell transfer tank located in the C Tank Farm, and 241-AY-102 (AY-102) double shell receiver tanks (DST) located in the Aging Waste Facility (AWF). The Waste Retrieval Sluicing System consists of two transfer lines that would connect the two tanks, one to carry the sluiced waste slurry to AY-102, and the other to return the supernatant liquid to C-106. The supernatant, or alternate fluid, will be used to mobilize waste in C-106 for the sluicing process. The equipment necessary for the WRSS include pumps in each tank, sluicers to direct the supernatant stream in C-106, a slurry distributor in AY-102, HVAC for C-106, instrumentation and control devices, and other existing components as required

  3. Regulatory Experience of the Embedded Digital Devices for Safety I and C Systems on Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y. M.; Lee, H. K.; Park, H. S. [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2016-10-15

    Conventional I and C(Instrumentation and Control) systems are tend to becoming unavailable and being replaced by smart equipment. These smart equipment is usually called embedded digital devices (EDDs) or industrial digital devices of limited functionality. Usually, some of these devices are found embedded in plant equipment such as sensing instrumentation, motors, pumps, actuators and breakers. They typically have a micro-processor, RAM, communication interface, a power source, etc. The U.S. Nuclear Regulatory Commission (US NRC) is concerning that these EDDs might exist in procured equipment used in safety systems without the devices having been explicitly identified in procurement documentation. This paper addresses the regulatory experiences of KINS of the EDDs for safety I and C systems and the future works for them. In this paper, we showed regulatory experiences of EDDs which used for safety grade equipment. EDDs might exist in safety grade procured equipment without explicit identification. Undetected defects of EDDs might be the potential safety concerns. EDDs should meet certain specific requirements in order to be selected and used in safety I and C system. We have plan to develop technical positions for identification and qualifying them. The technical position will address, but may not be limited to, quality and reliability, CCFs via software errors, EMC, and CGID for EDDs.

  4. [Equipment design for magnetic therapy and "Polus" devices].

    Science.gov (United States)

    Viktorov, V A; Malkov, Iu V

    1994-01-01

    Low-frequency magnetotherapy is among the most original therapeutical techniques since it is effective in treating most diseases and has practically no contraindications. Due to atraumaticity of a low-frequency electromagnetic field, the application of magnetotherapy is indicated in geriatric care, in particular. The VNIIMP-VITA Joint-Stock Company has developed a family of the Polyus system equipment for magnetotherapy, whereby all the well-known therapeutical procedures of low-frequency magnetotherapy can be performed. The magnetotherapeutic room equipped with Polyus-2D, Polyus-3, and Polyus-4 ensures a complete set of magneto-therapeutical exposure. The rooms are supplied by the VNIIMP-VITA Joint-Stock Company.

  5. Safety syringes and anti-needlestick devices in orthopaedic surgery.

    Science.gov (United States)

    Sibbitt, Wilmer L; Band, Philip A; Kettwich, Lawrence G; Sibbitt, Cristina R; Sibbitt, Lori J; Bankhurst, Arthur D

    2011-09-07

    The American Academy of Orthopaedic Surgery (AAOS), The Joint Commission, the Occupational Safety and Health Administration (OSHA), and the Needlestick Safety and Prevention Act encourage the integration of safety-engineered devices to prevent needlestick injuries to health-care workers and patients. We hypothesized that safety syringes and needles could be used in outpatient orthopaedic injection and aspiration procedures. The study investigated the orthopaedic uses and procedural idiosyncrasies of safety-engineered devices, including (1) four safety needles (Eclipse, SafetyGlide, SurGuard, and Magellan), (2) a mechanical safety syringe (RPD), (3) two automatic retractable syringes (Integra, VanishPoint), (4) three manual retractable syringes (Procedur-SF, Baksnap, Invirosnap), and (5) three shielded syringes (Safety-Lok, Monoject, and Digitally Activated Shielded [DAS] Syringe). The devices were first tested ex vivo, and then 1300 devices were used for 425 subjects undergoing outpatient arthrocentesis, intra-articular injections, local anesthesia, aspiration biopsy, and ultrasound-guided procedures. During the clinical observation, there were no accidental needlesticks (0 needlesticks per 1300 devices). Safety needles could be successfully used on a Luer syringe but were limited to ≤1.5 in (≤3.81 cm) in length and the shield could interfere with sonography. The mechanical safety syringes functioned well in all orthopaedic procedures. Automatic retractable syringes were too small for arthrocentesis of the knee, and the plunger blew out and prematurely collapsed with high-pressure injections. The manual retractable syringes and shielded syringes could be used with conventional needles for most orthopaedic procedures. The most effective and reliable safety devices for orthopaedic syringe procedures are shielded safety needles, mechanical syringes, manual retractable syringes, and shielded syringes, but not automatic retractable syringes. Even when adopting

  6. Vapor generator equipped with a migrant body trapping device

    International Nuclear Information System (INIS)

    Pascal, Y.

    1994-01-01

    In a nuclear plant vapor generator, a device is foreseen to prevent objects coming from dryers, further to assembly, to subsequent interventions or to a fortuitous removal when operating, from coming jam between generator tubes. This device, which for example looks like a grid, is put above an horizontal plate to which are fixed the high ends of the pipes containing the cyclone separators. It determines crossings whose higher dimensions are lower to the minimal gap separating the tubes. (Author). 2 figs., 3 refs

  7. Clothing, equipment and devices for personnel protection: Its selection according to occupational risks

    International Nuclear Information System (INIS)

    1989-01-01

    This Venezuelan standard establishes the selection of the type of clothing, equipment and devices for personnel protection, to be used by workers according to the occupational risk they deal with, in order to avoid or to reduce the factors that can, directly or indirectly, affect their physical integrity. For the risks not contemplated in this norm, the selection of the type of clothing, equipment and devices for personnel protection, must be done following the corresponding international standard [es

  8. An evaluation of sharp safety blood evacuation devices.

    Science.gov (United States)

    Ford, Joanna; Phillips, Peter

    This article describes an evaluation of three sharp safety blood evacuation devices in seven Welsh NHS boards and the Welsh Blood Service. Products consisted of two phlebotomy needles possessing safety shields and one phlebotomy device with wings, tubing and a retractable needle. The device companies provided the devices and appropriate training. Participating healthcare workers used the safety device instead of the conventional device to sample blood during the evaluation period and each type of device was evaluated in random order. Participants filled in a questionnaire for each type of device and then a further questionnaire comparing the two shielded evacuation needles with each other Results showed that responses to all three products were fairly positive, although each device was not liked by everyone who used it. When the two shielded evacuation devices were compared with each other, most users preferred the device with the shield positioned directly above the needle to the device with the shield at the side. However, in laboratory tests, the preferred device produced more fluid splatter than the other shielded device on activation.

  9. Safety systems I/C equipment reliability analyses of the Kozloduy NPP units 3 and 4

    Energy Technology Data Exchange (ETDEWEB)

    Halev, G; Christov, N [Risk Engineering Ltd., Sofia (Bulgaria)

    1996-12-31

    The purpose of the analysis is to assess the safety systems I/C equipment reliability. The assessment includes: quantification of the safety systems unavailability due to component failures; definition of the minimal cut sets leading to the analysed safety systems failure; quantification of the I/C equipment importance measures of the dominant contribution components. The safety systems I/C equipment reliability has been analysed using PSAPACK (a code for probabilistic safety assessment). Fault trees for the following safety systems of the Kozloduy-3 and Kozloduy-4 reactors have been constructed: neutron flow control equipment, reactor protection system, main coolant pumps, pressurizer safety valves `Sempell`, steam dump systems, spray system, low pressure injection system, emergency feeding water system, essential service water system. THree separate reports have been issued containing the performed analyses and results. 1 ref.

  10. A study on developpement of guideline on writing technical document for electrical medical devices: Dental x-ray equipment

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Youl; Kim, Jae Ryang; Lee, Jun Ho; Park, Chang Won [Division of Medical Device Research, National Institute of Food and Drug Safety Evaluation, Mnistry of Food and Drug Safety (Korea, Republic of)

    2016-12-15

    Due to recent population aging, the number of check-up for senior citizens has increased steadily. According to this trend, the market size of dental X-ray equipment and the number of approval and review for these devices have simultaneously increased. The technical document of medical device is required for approval and review for medical device, and medical device companies needs to have work comprehension and expertise, as the document needs to include the overall contents such as performances, test criteria, etc.. Yet, since most of domestic manufacturers or importers of medical devices are small businesses, it is difficult for them to recruit professional manpower for approval of medical devices, and submission of inaccurate technical documents has increased. These problems lead to delay of the approval process and to difficulties in quick entering into the market. Especially, the Ministry of Food and Drug safety (MFDS) standards of a dental extra-oral X-ray equipment, a dental intra-oral X-ray equipment, an arm-type computed tomography, and a portable X-ray system have been recently enacted or not. this guideline of dental X-ray equipment adjusting revised standards was developed to help relative companies and reviewers. For this study, first, the methods to write technical document have been reviewed with revised international and domestic regulations and system. Second, the domestic and foreign market status of each item has been surveyed and analyzed. Third, the contents of technical documents already approved by MFDS have been analyzed to select the correct example, test items, criteria, and methods. Finally, the guideline has been developed based on international and domestic regulation, through close review of a consultative body composed of academic, industrial, research institute and government experts.

  11. A study on developpement of guideline on writing technical document for electrical medical devices: Dental x-ray equipment

    International Nuclear Information System (INIS)

    Lee, Seung Youl; Kim, Jae Ryang; Lee, Jun Ho; Park, Chang Won

    2016-01-01

    Due to recent population aging, the number of check-up for senior citizens has increased steadily. According to this trend, the market size of dental X-ray equipment and the number of approval and review for these devices have simultaneously increased. The technical document of medical device is required for approval and review for medical device, and medical device companies needs to have work comprehension and expertise, as the document needs to include the overall contents such as performances, test criteria, etc.. Yet, since most of domestic manufacturers or importers of medical devices are small businesses, it is difficult for them to recruit professional manpower for approval of medical devices, and submission of inaccurate technical documents has increased. These problems lead to delay of the approval process and to difficulties in quick entering into the market. Especially, the Ministry of Food and Drug safety (MFDS) standards of a dental extra-oral X-ray equipment, a dental intra-oral X-ray equipment, an arm-type computed tomography, and a portable X-ray system have been recently enacted or not. this guideline of dental X-ray equipment adjusting revised standards was developed to help relative companies and reviewers. For this study, first, the methods to write technical document have been reviewed with revised international and domestic regulations and system. Second, the domestic and foreign market status of each item has been surveyed and analyzed. Third, the contents of technical documents already approved by MFDS have been analyzed to select the correct example, test items, criteria, and methods. Finally, the guideline has been developed based on international and domestic regulation, through close review of a consultative body composed of academic, industrial, research institute and government experts

  12. IEEE standard for design qualification of safety systems equipment used in nuclear power generating stations

    International Nuclear Information System (INIS)

    Anon.

    1980-01-01

    This standard is written to serve as a general standard for qualification of all types of safety systems equipment, mechanical and instrumentation as well as electrical. It also establishes principles and procedures to be followed in preparing specific safety systems equipment standards. Guidance for qualifying specific safety systems equipment may be found in various specific equipment qualification standards that are now available or are being prepared. It is required that safety systems equipment in nuclear power generating stations meet or exceed its performance requirements throughout its installed life. This is accomplished by a disciplined program of design qualification and quality assurance of design, production, installation, maintenance and surveillance. This standard is for the design qualification section of the program only. Design qualification is intended to demonstrate the capability of the equipment design to perform its safety function(s) over the expected range of normal, abnormal, design basis event, post design basis event, and in-service test conditions. Inherent to design qualification is the requirement for demonstration, within limitations afforded by established technical state-of-the-art, that in-service aging throughout the qualified life established for the equipment will not degrade safety systems equipment from its original design condition to the point where it cannot perform its required safety function(s), upon demand. The above requirement reflects the primary role of design qualification to provide reasonable assurance that design- and age-related common failure modes will not occur during performance of safety function(s) under postulated service conditions

  13. 1E Qualification of Electrical Equipment - Requirement for Safety Nuclear Power Plants

    International Nuclear Information System (INIS)

    Geambasu, C.; Segarceanu, D.; Albu, J.

    2002-01-01

    The paper presents the qualification methods of the safety related equipment according to the safety class 1E. There are presented the qualification principles, procedure and documents, emphasis being laid on the qualification approach by type tests. This approach assumes the equipment test under both normal and accident conditions (design basis events) simulating the operational conditions and covers the largest part of electrical equipment from a nuclear power plant.The safety related equipment is to be qualified is subjected to a sequential test that will be detailed in the paper. (author)

  14. A Handbook for Public Playground Safety. Volume II: Technical Guidelines for Equipment and Surfacing.

    Science.gov (United States)

    Consumer Product Safety Commission, Washington, DC.

    This handbook suggests safety guidelines for public playground equipment and describes various surfaces used under the equipment and possible injuries resulting from falls. The handbook is intended for use mainly by manufacturers, installers, school and park officials, and others interested in technical criteria for public playground equipment.…

  15. AERB information booklet: personal protective equipment- safety footwear

    International Nuclear Information System (INIS)

    1992-01-01

    The main classes of safety footwear required for industrial operations in the units of Department of Atomic Energy are the following; leather safety boots and shoes, firemen's leather boots - Wellington type, electrical safety shoes, chemical safety shoes, shoes suitable for mining operations. The criteria to be adopted for selection of safety shoes for nuclear installations are given. (M.K.V.). 5 annexures, 1 appendix

  16. Safety problems with the use of medical equipment/devices

    NARCIS (Netherlands)

    Rademakers, C.

    2009-01-01

    In the past decennia medical technology has rapidly developed. Nowadays it plays an important role in all medical fields. It introduced technologic solutions for many medical problems and it definitely increased the possibilities in the medical field to increase the quality of life. However with

  17. Safety considerations in the design of the fusion engineering device

    International Nuclear Information System (INIS)

    Barrett, R.J.

    1983-01-01

    Safety considerations play a significant role in the design of a near-term Fusion Engineering Device (FED). For the safety of the general public and the plant workers, the radiation environment caused by the reacting plasma and the potential release of tritium fuel are the dominant considerations. The U.S. Department of Energy (DOE) regulations and guidelines for radiation protection have been reviewed and are being applied to the device design. Direct radiation protection is provided by the device shield and the reactor building walls. Radiation from the activated device components and the tritium fuel is to be controlled with shielding, contamination control, and ventilation. The potential release of tritium from the plant has influenced the selection of reactor building and plant designs and specifications. The safety of the plant workers is affected primarily by the radiation from the activated device components and from plasma chamber debris. The highly activated device components make it necessary to design many of the maintenance activities in the reactor building for totally remote operation. The hot cell facility has evolved as a totally remote maintenance facility due to the high radiation levels of the device components. Safety considerations have had substantial impacts on the design of FED. Several examples of safety-related design impacts are discussed in the paper. Feasible solutions have been identified for all outstanding safety-related items, and additional optimization of these solutions is anticipated in future design studies

  18. A new approach to determine the environmental qualification requirements for the safety related equipment

    International Nuclear Information System (INIS)

    Hasnaoui, C.; Parent, G.

    2000-01-01

    The objective of the environmental qualification of safety related equipment is to ensure that the plant defense-in-depth is not compromised by common mode failures following design basis accidents with a harsh environment. A new approach based on safety functions has been developed to determine what safety-related equipment is required to function during and after a design basis accident, as well as their environmental qualification requirements. The main feature of this approach is to use auxiliary safety functions established from safety requirements as credited in the safety analyses. This approach is undertaken in three steps: identification of the auxiliary safety functions of each main safety function; determination of the main equipment groups required for each auxiliary safety function; and review of the safety analyses for design basis accidents in order to determine the credited auxiliary safety functions and their mission times for each accident scenario. Some of the benefits of the proposed approach for the determination of the safety environmental qualification requirements are: a systematic approach for the review of safety analyses based on a safety function check list, and the insurance, with the availability of the safety functions, that Gentilly-2 defense-in-depth would not be compromised by design basis accidents with a harsh environment. (author)

  19. Alternative water injection device to reactor equipment facility

    International Nuclear Information System (INIS)

    Yamashita, Masahiro.

    1995-01-01

    The device of the present invention injects water to the reactor and the reactor container continuously for a long period of time for preventing occurrence of a severe accident in a BWR type reactor and maintaining the integrity of the reactor container even if the accident should occur. Namely, diesel-driven pumps disposed near heat exchangers of a reactor after-heat removing system (RHR) are operated before the reactor is damaged by the after heat to cause reactor melting. A sucking valve disposed to a pump sucking pipeline connecting a secondary pipeline of the RHR heat exchanger and the diesel driving pump is opened. A discharge valve disposed to a pump discharge pipeline connecting a primary pipeline of the RHR heat exchanger and the diesel driving pump is opened. With such procedures, sea water is introduced from a sea water taking port through the top end of the secondary pipeline of the RHR heat exchanger and water is injected into the inside of the pressure vessel or the reactor container by way of the primary pipeline of the RHR heat exchanger. As a result, the reactor core is prevented from melting even upon occurrence of a severe accident. (I.S.)

  20. Safety work with MRI devices in medicine

    International Nuclear Information System (INIS)

    Zivkovic, D.; Hrnjak, M.

    1999-01-01

    This paper gives the basis of biological effects of physical factors which could affect personnel working on MRI devices and patients, and corresponding protection measures. Medical personnel working with MRI devices and patients could be exposed to static magnetic field, time varying fields and radiofrequency radiation, danger from electric current and chemical matters, and there is a high risk from moving metal objects which could wound the persons near-by. The protection from static magnetic field could be ensured by increasing the distance from the source. If MRI device is put in Faradays cage it could be corresponding protection of radiofrequency radiation. (author)

  1. Motorcycle safety device investigation: A case study on airbags

    Indian Academy of Sciences (India)

    analysis methods for research evaluation of rider crash protective devices fitted to ... The safety evaluation is then based on simulation of the 200 impact types. ... with recording of ISO 13232 car-front impact tests to evaluate the qualitative.

  2. The basic discussion on nuclear power safety improvement based on nuclear equipment design

    International Nuclear Information System (INIS)

    Zhao Feiyun; Yao Yangui; Yu Hao; He Yinbiao; Gao Lei; Yao Weida

    2013-01-01

    The safety of strengthening nuclear power design was described based on nuclear equipment design after Fukushima nuclear accident. From these aspects, such as advanced standard system, advanced design method, suitable test means, consideration of beyond design basis event, and nuclear safety culture construction, the importance of nuclear safety improvement was emphatically presented. The enlightenment was given to nuclear power designer. (authors)

  3. Staff report on the environmental qualification of safety-related electrical equipment

    International Nuclear Information System (INIS)

    1977-12-01

    The current NRC safety review process for nuclear power plants includes criteria related to the qualification of certain electrical equipment. These criteria require that electrical equipment important to safety must be qualified to function in the environment that might result from various accident conditions. Although such criteria have been applied since the early days of commercial nuclear power, the details of these criteria have been changed over the years. The evolution of environmental qualification of safety-related electrical equipment is described in Appendix A

  4. Safety and feasibility research of CIPT-Ⅱ irradiation device

    International Nuclear Information System (INIS)

    Zhang Zhihua; Mi Xiangmiao; Li Rundong

    2014-01-01

    CITP-Ⅱ irradiation device, which is specially designed for fusion tritium breeder research, works in a thermal neutron reactor. With lithium orthosilicate as the breeder, the safety analysis was done to work out the device's influence on physical parameters of the reactor and get the breeder's temperature distribution and thermo-technical features in the n-γ field. The stiffness and strength were checked, and also the safety characters of the device were assessed. The feasibility of gap gas regulating the temperature and gas refueling the breeder was demonstrated. The calculation and analysis results provide data for comprehensive performance assessment. (authors)

  5. Rumble devices for road traffic safety

    CSIR Research Space (South Africa)

    Jobson, AJ

    1973-01-01

    Full Text Available on the approaches to hazardous curves or intersections. City and town engineers had little to report on rumble installations but showed a keen interest in their potential usefulness. Each type of rumble device has certain merits and these are discussed...

  6. Recommended safety procedures for the selection, installation and use of baggage inspection x-ray equipment

    International Nuclear Information System (INIS)

    1978-05-01

    Good X-ray equipment alone will not preclude unnecessary exposure to x-radiation. The equipment must be installed, maintained and used by adequately trained personnel, with due regard for the inherent hazards of such equipment and an appreciation of the need to observe proper operational procedures. It is the intent of this Code to define equipment specifications and conditions of installation and use for baggage inspection X-ray equipment, such that the hazard to operating personnel and the general public from such devices remains negligibly small. (auth)

  7. Supraglottic devices as alternative equipment to airway management in state of sudden cardiac arrest

    Directory of Open Access Journals (Sweden)

    Rafał Czyż

    2017-08-01

    All of supraglottic devices are characterized by easiness in applying without experience in use them. Additionally time need to airway management in use of them is many times shorter than with traditional endotracheal intubation. Fundamental defect in these devices is a fact that they don’t provide total safety before aspiration for chime. Current literature shows us that supraglottic airway devices are perfect alternative to endotracheal intubation.

  8. The tendency of medical electrical equipment - IEC 60601-2-54: Particular requirements for the basic safety and essential performance of x-ray equipment for radiography and radioscopy

    International Nuclear Information System (INIS)

    Roh, Young Hoon; Kim, Jung Min

    2015-01-01

    Medical electrical equipment - Part 1: General requirement for basic safety and essential performance of MFDS was revised as 3th edition and Medical electrical equipment Part 2-54: Particular requirements for the basic safety and essential performance of X-ray equipment will be expected to be announced as notification. Therefore this technical report was written to introduce provision of the particular requirements, replacement, addition, amendment. The purpose of this particular requirements is to secure requirements for basic safety and essential performance of X-ray equipment for radiography and radioscopy. X-ray high voltage generator, mechanical protective device, protection against radiation is included in this particular requirements. Medical electrical equipment - Part 1, Part 1-2, Part 1-3 is applied to this particular requirements. If the requirements is announced as notification, It is expected to widen understanding for basic safety and essential performance of X-ray equipment for radiography and radioscopy and play a part to internationalize of medical equipment

  9. Simulating The Technological Movements Of The Equipment Used For Manufacturing Prosthetic Devices Using 3D Models

    Science.gov (United States)

    Chicea, Anca-Lucia

    2015-09-01

    The paper presents the process of building geometric and kinematic models of a technological equipment used in the process of manufacturing devices. First, the process of building the model for a six axes industrial robot is presented. In the second part of the paper, the process of building the model for a five-axis CNC milling machining center is also shown. Both models can be used for accurate cutting processes simulation of complex parts, such as prosthetic devices.

  10. Tritium radioluminescent devices, Health and Safety Manual

    Energy Technology Data Exchange (ETDEWEB)

    Traub, R.J.; Jensen, G.A.

    1995-06-01

    This document consolidates available information on the properties of tritium, including its environmental chemistry, its health physics, and safe practices in using tritium-activated RL lighting. It also summarizes relevant government regulations on RL lighting. Chapters are divided into a single-column part, which provides an overview of the topic for readers simply requiring guidance on the safety of tritium RL lighting, and a dual-column part for readers requiring more technical and detailed information.

  11. Tritium radioluminescent devices, Health and Safety Manual

    International Nuclear Information System (INIS)

    Traub, R.J.; Jensen, G.A.

    1995-06-01

    This document consolidates available information on the properties of tritium, including its environmental chemistry, its health physics, and safe practices in using tritium-activated RL lighting. It also summarizes relevant government regulations on RL lighting. Chapters are divided into a single-column part, which provides an overview of the topic for readers simply requiring guidance on the safety of tritium RL lighting, and a dual-column part for readers requiring more technical and detailed information

  12. Navigation Tools and Equipment and How They Have Improved Aviation Safety

    OpenAIRE

    Sulaiman D. S Alsahli FadalahassanALfadala

    2017-01-01

    This paper highlights the impact of navigation tools and equipment, such as the GPS, navigation radar, and other communications tools, which aid in ensuring aviation safety. It emphasizes the need for aviation safety and how these navigation methods are of great help to reduce the hazards and clearly indicate the problems related to the aircraft, aircraft traffic management, weather disturbances, among others. It also recommends how these tools and equipment must be further developed to promo...

  13. 49 CFR 214.507 - Required safety equipment for new on-track roadway maintenance machines.

    Science.gov (United States)

    2010-10-01

    ... maintenance machines. 214.507 Section 214.507 Transportation Other Regulations Relating to Transportation... Roadway Maintenance Machines and Hi-Rail Vehicles § 214.507 Required safety equipment for new on-track roadway maintenance machines. (a) Each new on-track roadway maintenance machine shall be equipped with: (1...

  14. FAST and SAFE Passive Safety Devices for Sodium-cooled Fast Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Hartanto, Donny; Kim, Chihyung; Kim, In-Hyung; Kim, Yonghee [KAIST, Daejeon (Korea, Republic of)

    2015-05-15

    The major factor is the impact of the neutron spectral hardening. The second factor that affects the CVR is reduced capture by the coolant when the coolant voiding occurs. To improve the CVR, many ideas and concepts have been proposed, which include introduction of an internal blanket, spectrum softening, or increasing the neutron leakage. These ideas may reduce the CVR, but they deteriorate the neutron economy. Another potential solution is to adopt a passive safety injection device such as the ARC (autonomous reactivity control) system, which is still under development. In this paper, two new concepts of passive safety devices are proposed. The devices are called FAST (Floating Absorber for Safety at Transient) and SAFE (Static Absorber Feedback Equipment). Their purpose is to enhance the negative reactivity feedback originating from the coolant in fast reactors. SAFE is derived to balance the positive reactivity feedback due to sodium coolant temperature increases. It has been demonstrated that SAFE allows a low-leakage SFR to achieve a self-shutdown and self-controllability even though the generic coolant temperature coefficient is quite positive and the coolant void reactivity can be largely managed by the new FAST device. It is concluded that both FAST and SAFE devices will improve substantially the fast reactor safety and they deserve more detailed investigations.

  15. Safety considerations in the design of the Fusion Engineering Device

    International Nuclear Information System (INIS)

    Barrett, R.J.

    1983-01-01

    The US Department of Energy (DOE) regulations and guidelines for radiation protection have been reviewed and are being applied to the device design. Direct radiation protection is provided by the device shield and the reactor building walls. Radiation from the activated device components and the tritium fuel is to be controlled with shielding, contamination control, and ventilation. The potential release of tritium from the plant has influenced the selection of reactor building and plant designs and specifications. The safety of the plant workers is affected primarily by the radiation from the activated device components and from plasma chamber debris

  16. A safety control device for detecting undesirable conditions

    Energy Technology Data Exchange (ETDEWEB)

    1974-09-26

    The invention relates to safety control devices. It deals with a device adapted to transmit a warning signal and to the detection of an undesirable condition in an associated apparatus, said device comprising switching means comprising transistors mounted in a reaction path, feeding means for opening the switching means whenever an undesirable condition has been detected by sensors, whereby an oscillator is caused to stop oscillating, and an outlet device controlled by the oscillator stoppage. This can be applied to the supervision of nuclear reactor.

  17. Design and fabrication of equipment and devices for a Radiotherapy department

    International Nuclear Information System (INIS)

    Picon, C.L.; Zaharia B, M.

    1998-01-01

    The objective of this work is to present the possibility to design and construct utilizing local technology, a series of equipment and devices necessaries for a routine in a Radiotherapy Department with typical budget in the Latin-American hospitals. (Author)

  18. 48 CFR 252.239-7016 - Telecommunications security equipment, devices, techniques, and services.

    Science.gov (United States)

    2010-10-01

    ... 48 Federal Acquisition Regulations System 3 2010-10-01 2010-10-01 false Telecommunications... SOLICITATION PROVISIONS AND CONTRACT CLAUSES Text of Provisions And Clauses 252.239-7016 Telecommunications... clause: Telecommunications Security Equipment, Devices, Techniques, and Services (DEC 1991) (a...

  19. System constitution of plasma high frequency heating device and element equipment

    International Nuclear Information System (INIS)

    Nagashima, Takashi

    1988-01-01

    On the high frequency heating device used for nuclear fusion experiment, the system constitution and the main items of development for the element equipment are described. As for the high frequency heating device, large technical progress was observed in the past 10 years as the second stage heating for tokamaks and one of the main means of current drive. At present, three frequency zones are regarded as promising for plasma high frequency heating in large nuclear fusion devices, and the experiment of 10 MW class is in progress at JT-60, JET and so on. There are electron cyclotron heating, lower hybrid resonance frequency heating and ion cyclotron range of frquency heating. The basic constitution of these heating devices includes a high frequency source, a transmission system, a connection system, and a common system for control, cooling, record and others. The ECH device using gyrotrons of several tens GHz, the LHRF heating device using large power klystrons up to several GHz and the ICRF heating device up to 200 MHz are briefly explained. The main element equipments composing the high frequency heating systems of several tens MW are discussed. (Kako, I.)

  20. L-038: EPR-First Responders: Forces / safety equipment. Action Guides

    International Nuclear Information System (INIS)

    2011-01-01

    This conference is about the actions carry out by the forces and the safety equipment in a radiological emergency. The security area, the victims, the hospitals, the police vehicles area, the safety cordon, the evacuation, the contamination level and the risk of life are important aspects to be considered by the first responders.

  1. 26 CFR 1.187-1 - Amortization of certain coal mine safety equipment.

    Science.gov (United States)

    2010-04-01

    ... 26 Internal Revenue 3 2010-04-01 2010-04-01 false Amortization of certain coal mine safety... (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Itemized Deductions for Individuals and Corporations (continued) § 1.187-1 Amortization of certain coal mine safety equipment. (a) Allowance of deduction—(1) In...

  2. 46 CFR 31.40-10 - Cargo Ship Safety Equipment Certificate-T/ALL.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 1 2010-10-01 2010-10-01 false Cargo Ship Safety Equipment Certificate-T/ALL. 31.40-10 Section 31.40-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS INSPECTION AND CERTIFICATION Certificates Under International Convention for Safety of Life at Sea, 1974 § 31.40-10 Cargo Ship...

  3. Application of quality assurance program to safety related aging equipment or components

    International Nuclear Information System (INIS)

    Papaiya, N.C.

    1990-01-01

    This paper addresses how quality assurance programs and their criteria are applied to safety related and aging equipment or components used in commercial nuclear plant applications. The QA Programs referred to are 10CFR50 Appendix B and EPRI NP-5652. The QA programs as applicable are applied to equipment/component aging qualification, preventive maintenance, surveillance testing and procurement engineering. The intent of this paper is not the technical issues, methods and research of aging. The paper addresses QA program's application to age-related equipment or components in safety related applications. Quality Assurance Program 10CFR50 Appendix B applies to all safety related aging components or equipment related to the qualification program and associated preventive maintenance and surveillance testing programs. Quality Assurance involvement with procurement engineering for age-related commercial grade items supports EPRI NP-5652 and assures that the dedicated OGI is equal to the item purchased as a basic component to 10CFR50 Appendix B requirements

  4. Safety of nursing staff and determinants of adherence to personal protective equipment.

    Science.gov (United States)

    Neves, Heliny Carneiro Cunha; Souza, Adenícia Custódia Silva e; Medeiros, Marcelo; Munari, Denize Bouttelet; Ribeiro, Luana Cássia Miranda; Tipple, Anaclara Ferreira Veiga

    2011-01-01

    A qualitative study conducted in a teaching hospital with 15 nursing professionals. Attempted to analyze the reasons, attitudes and beliefs of nursing staff regarding adherence to personal protective equipment. Data were collected through focus groups, analyzed by the method of interpretation of meanings, considering Rosenstock's model of health beliefs as a reference framework. Data revealed two themes: Occupational safety and Interpersonal Relationship. We identified several barriers that interfere in matters of safety and personal protective equipment, such as communication, work overload, physical structure, accessibility of protective equipment and organizational and management aspects. Adherence to personal protective equipment is determined by the context experienced in the workplace, as well as by individual values and beliefs, but the decision to use the personal protective equipment is individual.

  5. Construction Site Workers’ Awareness on Using Safety Equipment: Case Study

    Directory of Open Access Journals (Sweden)

    Ulang N. Md

    2014-01-01

    Full Text Available Construction sector is an important sector and contributed significantly to national development. However, this sector poses higher risk to accident. This is due to fact that construction site can be considered as a dangerous zone to workers and to the public. Due to the variety of cases occurs on site, the contractor will usually have to pay the cost related to accidents in the form of higher insurance premium. Despite various measures, accidents still occur at construction sites. Personal Protective Equipment (PPE is one of the important means to protect the wearer from hazards in the workplace. Since this equipment is the last frontier of the wearer from worksite hazards, it is important to select it based on the job scope and the intended protection. Therefore, this study was formulated to find out the level of knowledge and awareness of construction workers on PPE usage. It was also important to know what make the workers would want or do not want to use the PPE. It was found in this study that the level of awareness and knowledge among workers on the proper use of PPE is moderate. Construction sites accident can be further be reduced with proper implementation of PPE voluntarily by all workers.

  6. Criticality safety concerns of uranium deposits in cascade equipment

    International Nuclear Information System (INIS)

    Plaster, M.J.

    1996-01-01

    The Paducah and Portsmouth Gaseous Diffusion Plants enrich uranium in the 235 U isotope by diffusing gaseous uranium hexafluoride (UF 6 ) through a porous barrier. The UF 6 gaseous diffusion cascade utilized several thousand open-quotes stagesclose quotes of barrier to produce highly enriched uranium (HEU). Historically, Portsmouth has enriched the Paducah Gaseous Diffusion Plant's product (typically 1.8 wt% 235 U) as well as natural enrichment feed stock up to 97 wt%. Due to the chemical reactivity of UF 6 , particularly with water, the formation of solid uranium deposits occur at a gaseous diffusion plant. Much of the equipment operates below atmospheric pressure, and deposits are formed when atmospheric air enters the cascade. Deposits may also be formed from UF 6 reactions with oil, UF 6 reactions with the metallic surfaces of equipment, and desublimation of UF 6 . The major deposits form as a result of moist air in leakage due to failure of compressor casing flanges, blow-off plates, seals, expansion joint convolutions, and instrument lines. This report describes criticality concerns and deposit disposition

  7. A fence with several safety wires with alarm equipment

    International Nuclear Information System (INIS)

    Osterburg, G.

    1977-01-01

    The patent claim concerns a safety arrangement for objects in the open against unauthorised interference. A fence provided with several safety wires is used for this purpose. Each wire has a piezo-electric transmitter at one end, and has a piezo-electric receiver at the other end, which converts the mechanical vibrations into electrical signals. The piezo-electric receiver is connected via an amplifier to the piezo-electric transmitter of the next wire, which initiates the latter to produce mechanical vibrations and so on, until the transmitter of the first wire is reached again, so that a closed feed-back loop is formed. An electronic evaluation circuit is connected between one of the amplfiers and the subsequent transmitter, which on loss of vibration due to touching, hold. (ORU) [de

  8. Safety review for seismic qualification on nuclear power plant equipment

    International Nuclear Information System (INIS)

    Fang Qingxian

    1995-01-01

    The standards and requirements for seismic qualification of nuclear power plant's component have been fully addressed, including the scope of seismic qualification, the approach and the method of common seismic qualification, the procedure of the seismic tests, and the criteria for the seismic qualification review. The problems discovered in the safety review and the solution for these problems and some other issues are also discussed

  9. Push Off 2000 : new oilfield safety device catching on

    Energy Technology Data Exchange (ETDEWEB)

    Mowers, J.

    2006-12-15

    Fuel gas scrubbers use production gas to operate oil batteries, well separators, dehydrators, compressors, and pneumatic and pressure controls. Once an internal float gets stuck, production is stopped. The Push Off 2000 is a new safety device for fuel gas scrubbers which allows operators to easily dislodge a stuck internal float by activating the tool, which is mounted on top of the vessel. The device was developed after an operator suffered burns from a flash explosion that occurred after using a hammer to strike the fuel gas scrubber. The hammer method is the usual method of dealing with stuck internal floats, and can also jeopardize the integrity of the vessel, releasing gas or liquid hydrocarbons into the environment. The Push Off 2000 is expected to reduce costly facility downtime and increase revenue generating production time. Over 50 oil and gas companies have the Push Off 2000 device installed on fuel gas scrubber units at their facilities, and have recognized the safety and economic merits of the tool. The patented device has been approved by the Alberta Boilers Safety Association, the British Columbia Boiler and Elevator Safety Branch, and the Saskatchewan Boiler and Pressure Vessel Safety Unit. 1 fig.

  10. CFD Analysis of the Safety Injection Tank and Fluidic Device

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Jai Oan; Nietiadi, Yohanes Setiawan; Lee, Jeong Ik [KAIST, Daejeon (Korea, Republic of); Addad, Yacine [KUSTAR, Abu Dhabi (United Arab Emirates)

    2016-05-15

    One of the most important components in the ECCS is the safety injection tank (SIT). Inside the SIT, a fluidic device is installed, which passively controls the mass flow of the safety injection and eliminates the need for low pressure safety injection pumps. As more passive safety mechanisms are being pursued, it has become more important to understand flow structure and the loss mechanism within the fluidic device. Current computational fluid dynamics (CFD) calculations have had limited success in predicting the fluid flow accurately. This study proposes to find a more exact result using CFD and more realistic modeling to predict the performance during accident scenarios more accurately. The safety injection tank with fluidic device was analyzed thoroughly using CFD. The preliminary calculation used 60,000 meshes for the initial test calculation. The results fit the experimental results surprisingly despite its coarse grid. Nonetheless, the mesh resolution was increased to capture the vortex in the fluidic device precisely. Once a detailed CFD computation is finished, a small-scale experiment will be conducted for the given conditions. Using the experimental results and the CFD model, physical models can be improved to fit the results more accurately.

  11. Novel AC Servo Rotating and Linear Composite Driving Device for Plastic Forming Equipment

    Science.gov (United States)

    Liang, Jin-Tao; Zhao, Sheng-Dun; Li, Yong-Yi; Zhu, Mu-Zhi

    2017-07-01

    The existing plastic forming equipment are mostly driven by traditional AC motors with long transmission chains, low efficiency, large size, low precision and poor dynamic response are the common disadvantages. In order to realize high performance forming processes, the driving device should be improved, especially for complicated processing motions. Based on electric servo direct drive technology, a novel AC servo rotating and linear composite driving device is proposed, which features implementing both spindle rotation and feed motion without transmission, so that compact structure and precise control can be achieved. Flux switching topology is employed in the rotating drive component for strong robustness, and fractional slot is employed in the linear direct drive component for large force capability. Then the mechanical structure for compositing rotation and linear motion is designed. A device prototype is manufactured, machining of each component and the whole assembly are presented respectively. Commercial servo amplifiers are utilized to construct the control system of the proposed device. To validate the effectiveness of the proposed composite driving device, experimental study on the dynamic test benches are conducted. The results indicate that the output torque can attain to 420 N·m and the dynamic tracking errors are less than about 0.3 rad in the rotating drive. the dynamic tracking errors are less than about 1.6 mm in the linear feed. The proposed research provides a method to construct high efficiency and accuracy direct driving device in plastic forming equipment.

  12. Analysis of Medical Equipment Management in Relation to the Mandatory Medical Equipment Safety Manager (MESM in Japan

    Directory of Open Access Journals (Sweden)

    Kai Ishida

    2014-01-01

    Full Text Available Half a decade has passed since the fifth revision of the medical law and mandatory appointment of a medical equipment safety manager (MESM in hospitals in Japan. During this period, circumstances have changed regarding maintenance of medical equipment (ME. We conducted a survey to examine these changes and the current situation in ME management. Maintenance of ME and related work were found to have increased in many hospitals, but the number of clinical engineering technologists (CETs has only slightly increased. The appointed MESM was a CET or physician in most hospitals. In hospitals where physicians were appointed as the MESM, 81% had operation managers. Many respondents commented that it was difficult for one person to cover all the tasks required by the MESM, due to a lack of knowledge, too much work, or other reasons. This suggests the importance of an operation manager for ME to work under the MESM.

  13. Safety technology: Emergency equipment and sea rescue techniques

    Energy Technology Data Exchange (ETDEWEB)

    1986-06-01

    In June 1986, a two day workshop was convened to review mobile offshore drilling unit (MODU) evacuation research and development (R D) requirements for programs currently sponsored by the Marine Engineering Committee for PERD (Panel on Energy Research and Development) task 6.2. The proceedings of the workshop are presented in terms of: evacuation technology needs; a review of current R D projects for their relevance to the technological needs; recommended changes to current projects where warranted; and recommended priority R D projects that are not presently being undertaken to meet the evacuation technology needs. Current R D projects reviewed include: preferred orientation and displacement (PROD) lifeboat launching, personal transfer baskets, arctic escape system (AES), fast rescue craft (FRC), helicopter survival suits, diving bell emergency heaters, working immersion suits, diving bell emergency ascent system, undersea robotics systems and DCIEM decompression tables. It was concluded that gaps in offshore safety/evacuation capability cannot be adequately addressed by one or two major projects. Rather, a wider range of problems exist that require attention through a greater financial commitment than is presently the case. Government-industry cooperation in this field is required. Overall, the projects were judged to have been well planned, managed, and relevant to offshore safety needs. The only exception was a feeling that diving related projects consummed a disproportionate share of the available funding. Further, there was some reservation that the robotics study was outside the 6.2 PERD R D mandate. A list of recommendations is presented. 1 tab.

  14. Product-based Safety Certification for Medical Devices Embedded Software.

    Science.gov (United States)

    Neto, José Augusto; Figueiredo Damásio, Jemerson; Monthaler, Paul; Morais, Misael

    2015-01-01

    Worldwide medical device embedded software certification practices are currently focused on manufacturing best practices. In Brazil, the national regulatory agency does not hold a local certification process for software-intensive medical devices and admits international certification (e.g. FDA and CE) from local and international industry to operate in the Brazilian health care market. We present here a product-based certification process as a candidate process to support the Brazilian regulatory agency ANVISA in medical device software regulation. Center of Strategic Technology for Healthcare (NUTES) medical device embedded software certification is based on a solid safety quality model and has been tested with reasonable success against the Class I risk device Generic Infusion Pump (GIP).

  15. Photodetection, photon event localization and position tomography device comprising a gammagraphy camera equipped wit such devices

    International Nuclear Information System (INIS)

    Jatteau, M.R.

    1984-01-01

    This device of photodetection and photon event (and noticeably scintillations) localization comprises at least a photomultiplier tube with unique photomultiplying structure and in front of this tube, a net of juxtaposed conduction metal wires excited by voltage pulses. This net comprises only 2n metallic wires to assure the localization of 2sup(2n) possible positions, and that is one of its characteristics [fr

  16. Safety Features of Material and Personnel Movement Devices. Module SH-25. Safety and Health.

    Science.gov (United States)

    Center for Occupational Research and Development, Inc., Waco, TX.

    This student module on safety features of material and personnel movement devices is one of 50 modules concerned with job safety and health. This module covers safe conditions and operating practices for conveyors, elevators, escalators, moving walks, manlifts, forklifts, and motorized hand trucks. Following the introduction, 10 objectives (each…

  17. Factors affecting the utilization of safety devices by commercial ...

    African Journals Online (AJOL)

    Background: Motorcycle crashes are common causes of morbidity and mortality for both riders and passengers. To prevent and reduce the severity of injuries sustained through road traffic accidents (RTA) many countries enforce the use of safety devices while riding. Certain factors including non-enforcement of the existing ...

  18. Utilization of ocular safety devices among Sawmill workers in Nigeria

    African Journals Online (AJOL)

    Objective: The study was carried out to assess the use of eye safety devices in sawmill workers in Nigeria. Methods: A cross-sectional study of sawmill workers was carried out using pretested questionnaires. Ocular examination was done on site with a pen torch, portable hand-held slit lamp bio-microscope and direct ...

  19. A study on enforcement effects of radiation safety control regulations for diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Sung, Mo IL; Park, Myeong Hwan; Kwon, Duk Moon; Lee, Joon IL

    1999-01-01

    The purposes of this study are to analyze the realities after enforcements of safety control regulations for diagnostic X-ray equipment and to suggest means for an improvement of low radiation safety control. A questionnaire survey for medical radiologic technologists was carried out to determine enforcement effects of the safety control regulations. The results of analysis from the survey are as follows. That is, most of he respondents realized the importance of the radiation safety control system, but about a half of them revealed that regulations were not well observed in accordance with their purposes. Only 43.9 percent of the respondents took an active part in quality control of radiation. And responsibility, sex, age, and knowledge for safety control were important indicators for observations of the regulations. Training for the safety control regulations are needed to ensure safety control and proper usage of diagnostic X-ray equipment. And management of organizations using diagnostic X-ray equipment have to understand and stress the importance of radiation safety control system. (author)

  20. Use of digital computing devices in systems important to safety

    International Nuclear Information System (INIS)

    1986-01-01

    The incorporation of digital computing devices in systems important to safety now is progressing fast in several countries, including Canada, France, Federal Republic of Germany, Japan, USA. There are now reactors with microprocessors in some trip systems. The major functions of those systems are: reactor trip initiation, display, monitoring, testing, re-calibration of detectors. The benefits of moving to a fully computerized shut-down system should be improved reliability, greater flexibility, better man-machine interface, improved testing, higher reactor output and lower overall cost. With the introduction of computer devices in systems important to safety, plant availability and safety are improved because disturbances are treated before they lead to safety action, in this way helping the operator to avoid errors. The Meeting presentations were divided into sessions devoted to the following topics: Needs for the use of digital devices (DCD) in safety important systems (SIS) (5 papers); Problems raised by the integration SIS in the NPP control (7 papers); Description and presentation of DCD of SIS (6 papers); Results of experiences in engineering, manufacture, qualification operation of DCD hardware and software (5 papers). A separate abstract was prepared for each of these papers

  1. The design of an energy harvesting device for prolonging the working time of DC equipment

    Science.gov (United States)

    Wen, Yayuan; Deng, Huaxia; Zhang, Jin; Yu, Liandong

    2016-01-01

    Energy harvesting (EH) derives from the idea of converting the ambient energy into electric energy, which can solve the problem of DC supply for some electronic equipment. PZT is a typical piezoelectric material of inorganic, which has been developed as EH devices to transfer ambient vibration energy into electric energy. However, these PZT devices require relatively violent excitation, and easy to be fatigue fracture under the resonance condition. In this paper, PVDF, which is a kind of soft piezoelectric polymer, is adopted for developing transducer. The PVDF devices are flexible and have longer life time than PZT devices under the harmonic environment. The EH researches are mainly focused on the development of energy transfer efficiency either by the mechanical structure of transducer or the improvement of circuit. However, the practicality and stability of the EH devices are important in the practical engineering applications. In this paper, a charge amplifier is introduced in the circuit in order to guarantee the stability of the battery charging under small ambient vibration conditions. The model of the mechanical structure of PVDF and the electric performance of circuit are developed. The experimental results and simulation show that the stability of battery charging is improved and the working time of DC equipment is prolonged.

  2. MRI with cardiac pacing devicesSafety in clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Kaasalainen, Touko, E-mail: touko.kaasalainen@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Department of Physics, University of Helsinki (Finland); Pakarinen, Sami, E-mail: sami.pakarinen@hus.fi [HUS Department of Cardiology, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Kivistö, Sari, E-mail: sari.kivisto@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Holmström, Miia, E-mail: miia.holmstrom@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Hänninen, Helena, E-mail: helena.hanninen@hus.fi [HUS Department of Cardiology, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Peltonen, Juha, E-mail: juha.peltonen@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Department of Biomedical Engineering and Computational Science, School of Science, Aalto University, Helsinki (Finland); Lauerma, Kirsi, E-mail: kirsi.lauerma@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland); Sipilä, Outi, E-mail: outi.sipila@hus.fi [HUS Medical Imaging Center, Helsinki University Central Hospital, POB 340 (Haartmaninkatu 4), 00290 Helsinki (Finland)

    2014-08-15

    Objectives: The aim of this study was to introduce a single centre “real life” experience of performing MRI examinations in clinical practice on patients with cardiac pacemaker systems. Additionally, we aimed to evaluate the safety of using a dedicated safety protocol for these patients. Materials and methods: We used a 1.5 T MRI scanner to conduct 68 MRI scans of different body regions in patients with pacing systems. Of the cardiac devices, 32% were MR-conditional, whereas the remaining 68% were MR-unsafe. We recorded the functional parameters of the devices prior, immediately after, and approximately one month after the MRI scanning, and compared the device parameters to the baseline values. Results: All MRI examinations were completed safely, and each device could be interrogated normally following the MRI. We observed no changes in the programmed parameters of the devices. For most of the participants, the distributions of the immediate and one-month changes in the device parameters were within 20% of the baseline values, although some changes approached clinically important thresholds. Furthermore, we observed no differences in the variable changes between MR-conditional and MR-unsafe pacing systems, or between scans of the thorax area and other scanned areas. Conclusion: MRI in patients with MR-conditional pacing systems and selected MR-unsafe systems could be performed safely under strict conditions in this study.

  3. The Difficult Airway Society 'ADEPT' guidance on selecting airway devices: the basis of a strategy for equipment evaluation.

    Science.gov (United States)

    Pandit, J J; Popat, M T; Cook, T M; Wilkes, A R; Groom, P; Cooke, H; Kapila, A; O'Sullivan, E

    2011-08-01

    Faced with the concern that an increasing number of airway management devices were being introduced into clinical practice with little or no prior evidence of their clinical efficacy or safety, the Difficult Airway Society formed a working party (Airway Device Evaluation Project Team) to establish a process by which the airway management community within the profession could itself lead a process of formal device/equipment evaluation. Although there are several national and international regulations governing which products can come on to the market and be legitimately sold, there has hitherto been no formal professional guidance relating to how products should be selected (i.e. purchased). The Airway Device Evaluation Project Team's first task was to formulate such advice, emphasising evidence-based principles. Team discussions led to a definition of the minimum level of evidence needed to make a pragmatic decision about the purchase or selection of an airway device. The Team concluded that this definition should form the basis of a professional standard, guiding those with responsibility for selecting airway devices. We describe how widespread adoption of this professional standard can act as a driver to create an infrastructure in which the required evidence can be obtained. Essential elements are that: (i) the Difficult Airway Society facilitates a coherent national network of research-active units; and (ii) individual anaesthetists in hospital trusts play a more active role in local purchasing decisions, applying the relevant evidence and communicating their purchasing decisions to the Difficult Airway Society. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

  4. Impact of pre-conditioning on the qualification of safety-related equipment

    International Nuclear Information System (INIS)

    Isgro, J.R.

    1982-01-01

    This paper shares some recent experiences on the effects of preconditioning on the qualification of safety-related equipment not located in a harsh environment. Environmental and seismic qualification testing programs were conducted following the guidelines of IEEE 323-1974, IEEE 344-1975 and appropriate IEEE daughter standards, where available. The examples that follow will illustrate the degree of pre-conditioning of safety-related equipment qualified to the requirements of IEEE-323-1974, and its effect on the outcome of the qualification program

  5. Investigation of potential fire-related damage to safety-related equipment in nuclear power plants

    International Nuclear Information System (INIS)

    Wanless, J.

    1985-11-01

    Based on a review of vendor information, fire damage reports, equipment qualification and hydrogen burn test results, and material properties, thirty-three types of equipment found in nuclear power plants were ranked in terms of their potential sensitivity to fire environments. The ranking considered both the functional requirements and damage proneness of each component. A further review of the seven top-ranked components was performed, considering the relative prevalence and potential safety significance of each. From this, relays and hand switches dominate as first choices for fire damage testing with logic equipment, power supplies, transmitters, and motor control centers as future candidates

  6. Technical diagnostics - equipment monitoring for increasing safety and availability of nuclear power plants

    International Nuclear Information System (INIS)

    Sturm, A.; Foerster, R.

    1977-01-01

    Utilization of technical diagnostics in equipment monitoring of nuclear power plants for ensuring nuclear safety, economic availability, and for decision making on necessary maintenance is reviewed. Technical diagnostics is subdivided into inspection and early detection of malfunctions. Moreover, combination of technical diagnostics and equipment monitoring, integration of technical diagnostics into maintenance strategy, and problems of introducing early detection of malfunctions into maintenance management of nuclear power plants are also discussed. In addition, a compilation of measuring techniques used in technical diagnostics has been made. The international state of the art of equipment monitoring in PWR nuclear power plants is illustrated by description of the sound and vibration measuring techniques. (author)

  7. Unresolved Safety Issue A-46 - seismic qualification of equipment in operating plants

    International Nuclear Information System (INIS)

    Anderson, N.

    1985-01-01

    Seismic Qualification of Equipment in Operating Plants was designated as an Unresolved Safety Issue (USI) in December, 1980. The USI A-46 program was developed in early 1981 to investigate the adequacy of mechanical and electrical equipment in operating plants to withstand a safe shutdown earthquake. The approach taken was to develop viable, cost effective alternatives to current seismic qualification licensing requirements which could be applied to operating nuclear power plants. The tasks investigated include: (1) identification of seismic sensitive systems and equipment; (2) assessment of adequacy of existing seismic qualification methods; (3) development and assessment of in-situ test procedures to assist in qualification of equipment; (4) seismic qualification of equipment using seismic experience data; and (5) development of methods to generate generic floor response spectra. Progress to date and plans for completion of resolution are reported

  8. Design and construction of safety devices utilizing methods of measurement and control engineering

    Energy Technology Data Exchange (ETDEWEB)

    Greiner, B; Weidlich, S

    1982-08-01

    This article considers a proposed concept for the design and construction of measurement and control devices for the safety of chemical plants with the aim of preventing danger to persons and the environment and damage. Such measurement and control devices are generally employed when primary measures adopted for plant safety, such as safety valves, collection vessels, etc. are not applicable or insufficient by themselves. The concept regards the new sheet no. 3 of the VDI/VDE code draft 2180 ''Safety of chemical engineering plant'' and proposes a further subdivision of class A into safety classes A0, A1, and A2. Overall, it is possible, on the basis of the measures for raising the availability of measurement and control equipment which are presented in this article, to make selection appropriate to the potential danger involved. The proposed procedure should not, however, be regarded as a rigid scheme but rather as leading to a systematic view and supporting decisions resting on sound operating experience.

  9. Universal Safety Distance Alert Device for Road Vehicles

    Directory of Open Access Journals (Sweden)

    Matic Virant

    2016-04-01

    Full Text Available Driving with too short of a safety distance is a common problem in road traffic, often with traffic accidents as a consequence. Research has identified a lack of vehicle-mountable devices for alerting the drivers of trailing vehicles about keeping a sufficient safe distance. The principal requirements for such a device were defined. A conceptual study was performed in order to select the components for the integration of the device. Based on the results of this study, a working prototype of a flexible, self-contained device was designed, built and tested. The device is intended to be mounted on the rear of a vehicle. It uses radar as the primary distance sensor, assisted with a GPS receiver for velocity measurement. A Raspberry Pi single-board computer is used for data acquisition and processing. The alerts are shown on an LED-matrix display mounted on the rear of the host vehicle. The device software is written in Python and provides automatic operation without requiring any user intervention. The tests have shown that the device is usable on almost any motor vehicle and performs reliably in simulated and real traffic. The open issues and possibilities for future improvements are presented in the Discussion.

  10. Safety of Magnetic Resonance Imaging in Patients with Cardiac Devices.

    Science.gov (United States)

    Nazarian, Saman; Hansford, Rozann; Rahsepar, Amir A; Weltin, Valeria; McVeigh, Diana; Gucuk Ipek, Esra; Kwan, Alan; Berger, Ronald D; Calkins, Hugh; Lardo, Albert C; Kraut, Michael A; Kamel, Ihab R; Zimmerman, Stefan L; Halperin, Henry R

    2017-12-28

    Patients who have pacemakers or defibrillators are often denied the opportunity to undergo magnetic resonance imaging (MRI) because of safety concerns, unless the devices meet certain criteria specified by the Food and Drug Administration (termed "MRI-conditional" devices). We performed a prospective, nonrandomized study to assess the safety of MRI at a magnetic field strength of 1.5 Tesla in 1509 patients who had a pacemaker (58%) or an implantable cardioverter-defibrillator (42%) that was not considered to be MRI-conditional (termed a "legacy" device). Overall, the patients underwent 2103 thoracic and nonthoracic MRI examinations that were deemed to be clinically necessary. The pacing mode was changed to asynchronous mode for pacing-dependent patients and to demand mode for other patients. Tachyarrhythmia functions were disabled. Outcome assessments included adverse events and changes in the variables that indicate lead and generator function and interaction with surrounding tissue (device parameters). No long-term clinically significant adverse events were reported. In nine MRI examinations (0.4%; 95% confidence interval, 0.2 to 0.7), the patient's device reset to a backup mode. The reset was transient in eight of the nine examinations. In one case, a pacemaker with less than 1 month left of battery life reset to ventricular inhibited pacing and could not be reprogrammed; the device was subsequently replaced. The most common notable change in device parameters (>50% change from baseline) immediately after MRI was a decrease in P-wave amplitude, which occurred in 1% of the patients. At long-term follow-up (results of which were available for 63% of the patients), the most common notable changes from baseline were decreases in P-wave amplitude (in 4% of the patients), increases in atrial capture threshold (4%), increases in right ventricular capture threshold (4%), and increases in left ventricular capture threshold (3%). The observed changes in lead parameters

  11. Condition Monitoring and Fault Diagnosis for an Antifalling Safety Device

    Directory of Open Access Journals (Sweden)

    Guangxiang Yang

    2015-01-01

    Full Text Available There is a constant need for the safe operation and reliability of antifalling safety device (AFSD of an elevator. This paper reports an experimental study on rotation speed and catching torque monitoring and fault diagnosis of an antifalling safety device in a construction elevator. Denoising the signal using wavelet transform is presented in this paper. Based on the denoising effects for several types of wavelets, the sym8 wavelet basis, which introduces the high order approximation and an adaptive threshold, is employed for denoising the signal. The experimental result shows a maximum data error reduction of 7.5% is obtained and SNRs (signal-to-noise ratio of rotation speed and catching torque are improved for 3.9% and 6.4%, respectively.

  12. A safety equipment list for rotary mode core sampling systems operation in single shell flammable gas tanks; TOPICAL

    International Nuclear Information System (INIS)

    SMALLEY, J.L.

    1999-01-01

    This document identifies all interim safety equipment to be used for rotary mode core sampling of single-shell flammable gas tanks utilizing Rotary Mode Core Sampling systems (RMCS). This document provides the safety equipment for RMCS trucks HO-68K-4600, HO-68K-4647, trucks three and four respectively, and associated equipment. It is not intended to replace or supersede WHC-SD-WM-SEL-023, (Kelly 1991), or WHC-SD-WM-SEL-032, (Corbett 1994), which classifies 80-68K-4344 and HO-68K-4345 respectively. The term ''safety equipment'' refers to safety class (SC) and safety significant (SS) equipment, where equipment refers to structures, systems and components (SSC's). The identification of safety equipment in this document is based on the credited design safety features and analysis contained in the Authorization Basis (AB) for rotary mode core sampling operations in single-shell flammable gas tanks. This is an interim safety classification since the AB is interim. This document will be updated to reflect the final RMCS equipment safety classification designations upon completion of a final AB which will be implemented with the release of the Final Safety Analysis Report (FSAR)

  13. A safety equipment list for rotary mode core sampling systems operation in single shell flammable gas tanks

    International Nuclear Information System (INIS)

    SMALLEY, J.L.

    1999-01-01

    This document identifies all interim safety equipment to be used for rotary mode core sampling of single-shell flammable gas tanks utilizing Rotary Mode Core Sampling systems (RMCS). This document provides the safety equipment for RMCS trucks HO-68K-4600, HO-68K-4647, trucks three and four respectively, and associated equipment. It is not intended to replace or supersede WHC-SD-WM-SEL-023, (Kelly 1991), or WHC-SD-WM-SEL-032, (Corbett 1994), which classifies 80-68K-4344 and HO-68K-4345 respectively. The term ''safety equipment'' refers to safety class (SC) and safety significant (SS) equipment, where equipment refers to structures, systems and components (SSC's). The identification of safety equipment in this document is based on the credited design safety features and analysis contained in the Authorization Basis (AB) for rotary mode core sampling operations in single-shell flammable gas tanks. This is an interim safety classification since the AB is interim. This document will be updated to reflect the final RMCS equipment safety classification designations upon completion of a final AB which will be implemented with the release of the Final Safety Analysis Report (FSAR)

  14. On safety 1E qualification of electrical equipment for nuclear power stations

    International Nuclear Information System (INIS)

    Segarceanu, D.; Geambasu, C.; Avramescu, M.

    1995-01-01

    Electrical equipment and systems for the emergency shutdown of a nuclear reactor are qualified according to safety class 1E. Methods of qualification meeting the requirements should be used, either individually or in combination include, type-test qualification, qualification by operating experience, qualification by analysis, combined qualification. These methods qualification principles, procedures and documents are discussed. (N.T.). 1 fig

  15. Safety analysis report for packaging (onsite) decontaminated equipment self-container

    International Nuclear Information System (INIS)

    Boehnke, W.M.

    1998-01-01

    The purpose of this Safety Analysis Report for Packaging (SARP) is to demonstrate that specific decontaminated equipment can be safely used as its own self-container. As a Decontaminated Equipment Self-Container (also referred to as a self-container), no other packaging, such as a burial box, would be required to transport the equipment onsite. The self-container will consist of a piece of equipment or apparatus which has all readily removable interior contamination removed, all of its external openings sealed, and all external surfaces decontaminated to less than 2000 dpm/100 cm for gamma-emitting radionuclides and less than 220 dpm/100 CM2 for alpha-emitting radionuclides

  16. Equipment line-up developed for structuring programmed digital systems important to safety

    International Nuclear Information System (INIS)

    Remus, L.; Colling, J.M.; Buisson, J.

    1986-01-01

    The use of the programmed digital techniques in systems important to safety led to developing equipment line-ups which allow to procedure, through using a restricted number of sub-assemblies, a variety of facilities capable of performing diversified functions. Upon remembering the requirements that such equipment are required to meet (quality assurance both at the design and production stages, qualification, testing opportunities, etc.) the equipments produced by MERLIN GERIN are described in this paper. Such equipments include a whole set of printed circuit boards, plug-in units with self-engaging connectors and the related cabinets to accomodate them. The following systems are made up of such equipments: Digital integrated protection system; Rod control and monitoring system; Reactor power distribution monitoring equipment. This equipment line-up has been gradually complemented and is still further expanding both as a result of the component further development or for the purpose of meeting new requirements or applications (new digital neutron instrumentation, local area networks). Experience gained thus far provides us with the capability of working out in a short time programmed systems for further applications in the nuclear power field

  17. A Wii-controlled safety device for electric chainsaws

    Directory of Open Access Journals (Sweden)

    R. Gubiani

    2013-09-01

    Full Text Available Forestry continues to represent one of the most hazardous economic sectors of human activity, and historically, the operation of chainsaws has mainly been restricted to professional lumberjacks. In recent years, because of low cost, chainsaws have become popular among unprofessionals, e.g. for cutting firewood and trimming trees. Serious or lethal lesions due to the use of chainsaws or electric chainsaws are often observed by traumatologists or forensic pathologists. Such serious accidents often occur during occupational activities and are essentially due to kickback or uncorrected use of the tool, or when the operator falls down losing the control of the implement. A new device in order to stop a cutting chain was developed and adapted to an electric chainsaw. The device is based on a Wiimote controller (Nintendo™, including two accelerometers and two gyroscopes for detecting rotation and inclination. A Bluetooth wireless technology is used to transfer data to a portable computer. The data collected about linear and angular acceleration are filtered by an algorithm, based on the Euclid norm, capable to distinguishing between normal movements and dangerous chainsaw movements. The result show a good answer to device and when happen a dangerous situation an alarm signal is sent back to the implement in order to stop the cutting chain. The device show a correct behavior in tested dangerous situations and is envisaged to extend to combustion engine chainsaws, as well as to other portable equipment used in agriculture and forestry operations and for this objectives were patented.

  18. Periodic orbits of solar sail equipped with reflectance control device in Earth-Moon system

    Science.gov (United States)

    Yuan, Jianping; Gao, Chen; Zhang, Junhua

    2018-02-01

    In this paper, families of Lyapunov and halo orbits are presented with a solar sail equipped with a reflectance control device in the Earth-Moon system. System dynamical model is established considering solar sail acceleration, and four solar sail steering laws and two initial Sun-sail configurations are introduced. The initial natural periodic orbits with suitable periods are firstly identified. Subsequently, families of solar sail Lyapunov and halo orbits around the L1 and L2 points are designed with fixed solar sail characteristic acceleration and varying reflectivity rate and pitching angle by the combination of the modified differential correction method and continuation approach. The linear stabilities of solar sail periodic orbits are investigated, and a nonlinear sliding model controller is designed for station keeping. In addition, orbit transfer between the same family of solar sail orbits is investigated preliminarily to showcase reflectance control device solar sail maneuver capability.

  19. Evaluating and Predicting Patient Safety for Medical Devices With Integral Information Technology

    Science.gov (United States)

    2005-01-01

    323 Evaluating and Predicting Patient Safety for Medical Devices with Integral Information Technology Jiajie Zhang, Vimla L. Patel, Todd R...errors are due to inappropriate designs for user interactions, rather than mechanical failures. Evaluating and predicting patient safety in medical ...the users on the identified trouble spots in the devices. We developed two methods for evaluating and predicting patient safety in medical devices

  20. Development of a Test Equipment for Performance Evaluation of Safety Systems

    International Nuclear Information System (INIS)

    Kim, S. J.; Kwon, S. M.; Lee, J. M.; Kim, C. K.; Cho, C. H.; Chun, J. H.; Park, M. K.

    2004-07-01

    The purpose of this study is to develop a test equipment for performance evaluation of safety systems in nuclear power plants. First, we develop an input-output simulator for reactor protection systems, ESF component control systems, and a data acquisition system for these I/O simulators as a hardware for this equipment. Then, we develop a software for human-machine interface system, which is easy-to-use and easy-to-modify. In addition, a simulation tool for a reactor trip switch gear is developed

  1. An examination of safety reports involving electronic flight bags and portable electronic devices

    Science.gov (United States)

    2014-06-01

    The purpose of this research was to develop a better understanding of safety considerations with the use of Electronic Flight Bags (EFBs) and Portable Electronic Devices (PEDs) by examining safety reports from Aviation Safety Reporting System (ASRS),...

  2. Effect of electronic device use on pedestrian safety : a literature review.

    Science.gov (United States)

    2016-04-01

    This literature review on the effect of electronic device use on pedestrian safety is part of a research project sponsored by the Office of Behavioral Safety Research in the National Highway Traffic Safety Administration (NHTSA). An extensive literat...

  3. Safety plan for the cooperative telerobotic retrieval system equipment development area

    Energy Technology Data Exchange (ETDEWEB)

    Haney, T.J.; Jessmore, J.J.

    1995-07-01

    This plan establishes guidelines to minimize safety risks for the cooperative telerobotic retrieval project at the North Boulevard Annex (NBA). This plan has the dual purpose of minimizing safety risks to workers and visitors and of securing sensitive equipment from inadvertent damage by nonqualified personnel. This goal will be accomplished through physical control of work zones and through assigned responsibilities for project personnel. The scope of this plan is limited to establishing the working zone boundaries and entry requirements, and assigning responsibilities for project personnel. This plan does not supersede current safety organization responsibilities for the Landfill Stabilization Focus Area Transuranic (LSFA TRU) Arid outlined in the Environment, Safety, Health, and Quality Plan for the Buried Waste Integrated Demonstration Program; Tenant Manual; Idaho Falls Building Emergency Control Plan;; applicable Company Procedures; the attached Interface Agreement (Appendix A).

  4. Safety plan for the cooperative telerobotic retrieval system equipment development area

    International Nuclear Information System (INIS)

    Haney, T.J.; Jessmore, J.J.

    1995-07-01

    This plan establishes guidelines to minimize safety risks for the cooperative telerobotic retrieval project at the North Boulevard Annex (NBA). This plan has the dual purpose of minimizing safety risks to workers and visitors and of securing sensitive equipment from inadvertent damage by nonqualified personnel. This goal will be accomplished through physical control of work zones and through assigned responsibilities for project personnel. The scope of this plan is limited to establishing the working zone boundaries and entry requirements, and assigning responsibilities for project personnel. This plan does not supersede current safety organization responsibilities for the Landfill Stabilization Focus Area Transuranic (LSFA TRU) Arid outlined in the Environment, Safety, Health, and Quality Plan for the Buried Waste Integrated Demonstration Program; Tenant Manual; Idaho Falls Building Emergency Control Plan;; applicable Company Procedures; the attached Interface Agreement (Appendix A)

  5. ACCIDENT WITH NEEDLESTICK: KNOWLEDGE AND USE OF SAFETY DEVICE

    Directory of Open Access Journals (Sweden)

    Sandra Maria Souza da Silva

    2016-07-01

    Full Text Available Health workers engaged in labour activities in environments surrounded the occupational hazards. Identify knowledge and use of safety devide for preventing accidents with sharp objects between nurses and nurse technicians, workers of the Intensive Care Unit, Emergency and Surgical Block, during the month of may 2015. Exploratory study, quantitative, developed in a teaching hospital in in Recife-PE. The data collection was conducted using a questionnaire prepared by the research authors. The results were submitted to descriptive statistical analysis, being evidenced that, although data indicate high rate of respondents know and use products with referencing safety devices to prevent accidents, cite gloves and masks as representatives of those materials, which requires clarification in discussion of the study. It is necessary to guide and clarify as to such mechanisms, through the permanent education, and training among workers.

  6. The method for assurance to operational safety of cryogenics equipment through definite maintenance

    International Nuclear Information System (INIS)

    Anghel, Vasile

    2004-01-01

    The present paper reports about a method of ensuring operational safety of cryogenics equipment through specific maintenance measures which imply a definite concept of maintainability and operational reliability, methods of maintenance, necessary logistic and necessary personnel. The stages of the concept should succeed in a logical order and must be based on detailed analyses of the process of maintenance. The method starts from the operation conditions of cryogenic equipment in nuclear regime. Thus maintenance policy must be well defined within the boundaries of the nuclear plant through definition of coherent objectives and responsibility delegation for the personnel implied in maintenance activity. This method ensures performance in maintenance and an efficient feedback from equipment analysis. (author)

  7. Device for positioning and generation of an element of track model and slice of the MELAS automatic equipment

    International Nuclear Information System (INIS)

    Kryutchenko, E.V.; Fedotov, V.S.

    1979-01-01

    The structure and organization of the device for positioning and generation of element of track model and slice of the MELAS automatic equipment which is developed for measuring films from big bubble chambers, is described. Main features of the device are studied and characteristics are given as well

  8. Interim staff position on environmental qualification of safety-related electrical equipment: including staff responses to public comments. Regulatory report

    International Nuclear Information System (INIS)

    Szukiewicz, A.J.

    1981-07-01

    This document provides the NRC staff positions regarding selected areas of environmental qualification of safety-related electrical equipment, in the resolution of Unresolved Safety Issue A-24, 'Qualification of Class IE Safety-Related Equipment.' The positions herein are applicable to plants that are or will be in the construction permit (CP) or operating license (OL) review process and that are required to satisfy the requirements set forth in either the 1971 or the 1974 version of IEEE-323 standard

  9. Safety analysis report for packaging onsite long-length contaminated equipment transport system

    International Nuclear Information System (INIS)

    McCormick, W.A.

    1997-01-01

    This safety analysis report for packaging describes the components of the long-length contaminated equipment (LLCE) transport system (TS) and provides the analyses, evaluations, and associated operational controls necessary for the safe use of the LLCE TS on the Hanford Site. The LLCE TS will provide a standardized, comprehensive approach for the disposal of approximately 98% of LLCE scheduled to be removed from the 200 Area waste tanks

  10. Safety of nursing staff and determinants of adherence to personal protective equipment

    OpenAIRE

    Neves,Heliny Carneiro Cunha; Souza,Adenícia Custódia Silva e; Medeiros,Marcelo; Munari,Denize Bouttelet; Ribeiro,Luana Cássia Miranda; Tipple,Anaclara Ferreira Veiga

    2011-01-01

    A qualitative study conducted in a teaching hospital with 15 nursing professionals. Attempted to analyze the reasons, attitudes and beliefs of nursing staff regarding adherence to personal protective equipment. Data were collected through focus groups, analyzed by the method of interpretation of meanings, considering Rosenstock’s model of health beliefs as a reference framework. Data revealed two themes: Occupational safety and Interpersonal Relationship. We identified several barriers that i...

  11. Environmental qualification - walkdowns: The documentation of configuration information for safety related components, equipment and systems

    International Nuclear Information System (INIS)

    Melmer, J.; Waters, M.

    1995-01-01

    Environmental Qualification walkdowns are conducted to collect field data to verify/validate/document configurations of safety related equipment and systems. This paper describes the process for conducting walkdowns and the justification for using an electronic format. The following are described: a) Background; b) Preparing, executing and processing walkdowns; c) Hardware/software; d) Impact of a paperless system on walkdown execution, maintenance and work planning; e) Other applications for the technology

  12. Improvement suggestions on license extension management for civil nuclear safety equipment activities

    International Nuclear Information System (INIS)

    Sun Xingjian; Liu Hongji; Han Guoli; Jia Fengcai

    2013-01-01

    Based on the concepts of Clear Requirements, Comprehensive Review, Objective Assessment, Dynamic Management, this paper gives improvement suggestions on license extension management for civil nuclear safety equipment design, manufacture, installation and non-destructive examination activities, which include establishing a relatively unified license extension review standard, combining multi-views and close linking license review and supervision, full utilizing the daily supervision and inspection results, as well as further improving motivation and elimination mechanism. (authors)

  13. Safety analysis report for packaging, onsite, long-length contaminated equipment transport system

    Energy Technology Data Exchange (ETDEWEB)

    McCormick, W.A.

    1997-05-09

    This safety analysis report for packaging describes the components of the long-length contaminated equipment (LLCE) transport system (TS) and provides the analyses, evaluations, and associated operational controls necessary for the safe use of the LLCE TS on the Hanford Site. The LLCE TS will provide a standardized, comprehensive approach for the disposal of approximately 98% of LLCE scheduled to be removed from the 200 Area waste tanks.

  14. Safety and efficacy for new techniques and imaging using new equipment to support European legislation: An EU coordination action

    International Nuclear Information System (INIS)

    Zoetelief, J.; Faulkner, K.

    2008-01-01

    The past two decades have witnessed a technologically driven revolution in radiology. At the centre of these developments has been the use of computing. These developments have also been driven by the introduction of new detector and imaging devices in radiology and nuclear medicine, as well as the widespread application of computing techniques to enhance and extract information within the images acquired. Further advances have been introduced into digital practice. These technological developments, however, have not been matched by justification and optimisation studies to ensure that these new imaging devices and techniques are as effective as they might be, or performed at the lowest possible dose. The work programme of the SENTINEL Coordination Action was subdivided into eight work packages: functional performance and standards; efficacy and safety in digital radiology, dentistry and nuclear medicine, cardiology, interventional radiology, population screening/sensitive groups; justification, ethics and efficacy; good practice guidance and training; and project management. The intention of the work programme was to underwrite the safety, efficacy and ethical aspects of digital practice as well as to protect and add value to the equipment used in radiology. (authors)

  15. Verification of BGA type FPGA logic applied to a control equipment with Safety Class using the special socket

    International Nuclear Information System (INIS)

    Chung, YounHu; Yoo, Kwanwoo; Lee, Myeongkyun; Yun, Donghwa

    2015-01-01

    This article aims to provide the verification method for BGA-type FPGA of Programmable Logic Controller (PLC) developed as Safety Class. The logic of FPGA in the control device with Safety Class is the circuit to control overall logic of PLC. This device converts to the different module from the input signals for both digital and analogue of the equipment in the field and outputs their data. In addition, it should perform the logical controls such as backplane communication control and data communication. We suggest acquiring method of the data signal with efficient logic using the socket in this article. Proposed test socket is made by simpler process than former one, and the process is done in batches by which cost can be reduces, and the test socket can be quickly produced in response to any request. Also, it is possible to reduce the wear by reducing the contact force of the ball phenomenon. The structure on the basis of silicon can be reduced the modification, and it has excellent linearity. At the logic verification, the operation that state data block is designed in the FPGA could be easily confirmed by using a socket

  16. Spent nuclear fuel project cold vacuum drying facility safety equipment list

    International Nuclear Information System (INIS)

    IRWIN, J.J.

    1999-01-01

    This document provides the safety equipment list (SEL) for the Cold Vacuum Drying Facility (CVDF). The SEL was prepared in accordance with the procedure for safety structures, systems, and components (SSCs) in HNF-PRO-516, ''Safety Structures, Systems, and Components,'' Revision 0 and HNF-PRO-097, Engineering Design and Evaluation, Revision 0. The SEL was developed in conjunction with HNF-SO-SNF-SAR-O02, Safety Analysis Report for the Cold Vacuum Drying Facility, Phase 2, Supporting Installation of Processing Systems (Garvin 1998). The SEL identifies the SSCs and their safety functions, the design basis accidents for which they are required to perform, the design criteria, codes and standards, and quality assurance requirements that are required for establishing the safety design basis of the SSCs. This SEL has been developed for the CVDF Phase 2 Safety Analysis Report (SAR) and shall be updated, expanded, and revised in accordance with future phases of the CVDF SAR until the CVDF final SAR is approved

  17. Radiation protection in dentistry. Recommended safety procedures for the use of dental x-ray equipment. Safety code 30

    International Nuclear Information System (INIS)

    1994-01-01

    The Radiation Protection Bureau has prepared a series of documents on safety codes to set out requirements for the safe use of radiation-emitting equipment. This Safety Code has been prepared to provide specific guidance to the dentist, dental hygienist, dental assistant and other support personnel concerned with safety procedures and equipment performance. Dental radiography is one of the most valuable tools used in modern dental health care. It makes possible the diagnosis of physical conditions that would otherwise be difficult to identify. The use of dental radiological procedures must be carefully managed, because x-radiation has the potential for damaging healthy cells and tissues. Although no known occurrence of cancer or genetic damage has been observed from radiation doses delivered in modern dentistry, and until more evidence is available, one should practice radiation hygiene with the same care as would be dictated if a hazard were known to exist. The aim of radiation protection in dentistry is to obtain the desired clinical information with minimal radiation exposure to patients, dental personnel and the public. 15 tabs

  18. Radiation protection in dentistry. Recommended safety procedures for the use of dental x-ray equipment. Safety code 30

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The Radiation Protection Bureau has prepared a series of documents on safety codes to set out requirements for the safe use of radiation-emitting equipment. This Safety Code has been prepared to provide specific guidance to the dentist, dental hygienist, dental assistant and other support personnel concerned with safety procedures and equipment performance. Dental radiography is one of the most valuable tools used in modern dental health care. It makes possible the diagnosis of physical conditions that would otherwise be difficult to identify. The use of dental radiological procedures must be carefully managed, because x-radiation has the potential for damaging healthy cells and tissues. Although no known occurrence of cancer or genetic damage has been observed from radiation doses delivered in modern dentistry, and until more evidence is available, one should practice radiation hygiene with the same care as would be dictated if a hazard were known to exist. The aim of radiation protection in dentistry is to obtain the desired clinical information with minimal radiation exposure to patients, dental personnel and the public. 15 tabs.

  19. Preliminary safety equipment list for Tank 241-C-106 Manipulator Retrieval System, Project W-340

    International Nuclear Information System (INIS)

    Guthrie, R.L.

    1994-01-01

    This document identifies the anticipated safety classification of the estimated major subsystems, based on the projected major functions, that will be used as guidance for the development of the conceptual design of the Manipulator Retrieval System for Tank 241-C-106. This document is intended to be updated as the design of the Manipulator Retrieval System evolves through the conceptual and definitive design phases. The Manipulator Retrieval System is to be capable of removing the hardened sludge heel at the bottom of single shell Tank 241-C-106 and to perform an overall clean out of the tank that leaves a maximum of 360 ft 3 (TPA milestone M-45-00). The thickness of the heel prior to initiation of waste retrieval with the Manipulator Retrieval System is estimated to be 1- to 2-ft. The Manipulator Retrieval System is currently in the pre-conceptual phase with no definitive systems or subsystems. The anticipated retrieval functions for the Manipulator Retrieval System is based on Table 6-2 of WHC-SD-W340-ES-001, Rev. 1. Projected equipment to accomplish these functions were based on the following systems and equipment: Rotary Mode Core Sampling Equipment (WHC-SD-WM-SEL-032); Light Duty Utility Arm System Equipment (WHC-SD-WM-SEL-034); Single Shell Tanks Equipment (WHC-SD-WM-SEL-020)

  20. Evaluation of Generic Issue 57: Effects of fire protection system actuation on safety-related equipment

    International Nuclear Information System (INIS)

    Lambright, J.; Bohn, M.; Lynch, J.; Ross, S.; Brosseau, D.

    1992-12-01

    Nuclear power plants have experienced actuations of fire protection systems (FPSs) under conditions for which these systems were not intended to actuate and also have experienced advertent actuations with the presence of a fire. These actuations have often damaged safety-related equipment. A review of the impact of past occurrences of both types of such events and their impact on plant safety systems, an analysis of the risk impacts of such events on nuclear power plant safety, and a cost-benefit analysis of potential corrective measures have been performed. Thirteen different scenarios leading to actuation of fire protection systems due to a variety of causes were identified. These scenarios ranged from inadvertent actuation caused by human error to hardware failure, and include seismic root causes and seismic/fire interactions. A quantification of these thirteen root causes, where applicable, was performed on generically applicable scenarios. This document, Volume 4, contains appendices E and F of this report

  1. Fundamentals of a graded approach to safety-related equipment setpoints

    International Nuclear Information System (INIS)

    Woodruff, B.A.; Cash, J.S. Jr.; Bockhorst, R.M.

    1993-01-01

    The concept of using a graded approach to reconstitute instrument setpoints associated with safety-related equipment was first presented to the industry by the U.S. Nuclear Regulatory Commission during the 1992 ISA/POWID Symposium in Kansas City, Missouri. The graded approach establishes that the manner in which a utility analyzes and documents setpoints is related to each setpoint's relative importance to safety. This allows a utility to develop separate requirements for setpoints of varying levels of safety significance. A graded approach to setpoints is a viable strategy that minimizes extraneous effort expended in resolving difficult issues that arise when formal setpoint methodology is applied blindly to all setpoints. Close examination of setpoint methodology reveals that the application of a graded approach is fundamentally dependent on the analytical basis of each individual setpoint

  2. Factors Influencing the Safety Behavior of German Equestrians: Attitudes towards Protective Equipment and Peer Behaviors

    Directory of Open Access Journals (Sweden)

    Christina-Maria Ikinger

    2016-02-01

    Full Text Available Human interactions with horses entail certain risks. Although the acceptance and use of protective gear is increasing, a high number of incidents and very low or inconsistent voluntary use of safety equipment are reported. While past studies have examined factors influencing the use of safety gear, they have explored neither their influence on the overall safety behavior, nor their relative influence in relation to each other. The aim of the present study is to fill this gap. We conducted an online survey with 2572 participants. By means of a subsequent multiple regression analysis, we explored 23 different variables in view of their influence on the protective behavior of equestrians. In total, we found 17 variables that exerted a significant influence. The results show that both having positive or negative attitudes towards safety products as well as the protective behavior of other horse owners or riding pupils from the stable have the strongest influence on the safety behavior of German equestrians. We consider such knowledge to be important for both scientists and practitioners, such as producers of protective gear or horse sport associations who might alter safety behavior in such a way that the number of horse-related injuries decreases in the long term.

  3. Plant equipment integrity monitoring and diagnosing method and device therefor, plant equipment maintenance and inspection time determining method and device therefor, as well as nuclear power plant

    International Nuclear Information System (INIS)

    Kato, Takahiko; Ando, Masashi; Osumi, Katsumi; Horiuchi, Tetsuo; Asakura, Yamato; Akamine, Kazuhiko.

    1995-01-01

    The present invention can accurately forecast a time for occurrence of troubles of plant equipments in contact with recycling water, to conduct its maintenance and inspection before occurrence of the troubles. Namely, change of water quality in plant equipments caused by corrosion of recycling water occurred in constitutional parts of the plant equipments is measured. The time upon occurrence of the troubles of the plant equipments to corrosion of the recycling water is forecast based on the measured value. A time till the occurrence of the change of water quality after starting the use of the plant equipments is calculated based on the measured value. The calculated time is compared with a correlation between the time of occurrence of the troubles after starting the use of the plant equipments and the time of occurrence of change of the water quality, to forecast the time of occurrence of the troubles. Preferably, electroconductivity and pH of recycling water in the inside or at the exit of the plant equipments are measured as an object for the measurement of change of water quality. (I.S.)

  4. Seismic qualification of equipment in operating nuclear power plants: Unresolved Safety Issue A-46

    International Nuclear Information System (INIS)

    Chang, T.Y.

    1987-02-01

    The margin of safety provided in existing nuclear power plant equipment to resist seismically induced loads and perform their intended safety functions may vary considerably, because of significant changes in design criteria and methods for the seismic qualification of equipment over the years. Therefore, the seismic qualification of equipment in operating plants must be reassessed to determine whether requalification is necessary. The objective of technical studies performed under the Task Action Plan A-46 was to establish an explicit set of guidelines and acceptance criteria to judge the adequacy of equipment under seismic loading at all operating plants, in lieu of requiring qualification to the current criteria that are applied to new plants. This report summarizes the work accomplished on USI A-46. In addition, the collection and review of seismic experience data and existing seismic test data are presented. Staff assessment of work accomplished under USI A-46 leads to the conclusion that the use of seismic experience data provides the most reasonable alternative to current qualification criteria. Consideration of seismic qualification by use of experience data was a specific task in USI A-46. Several other A-46 tasks serve to support the use of an experienced data base. The principal technical finding of USI A-46 is that seismic experience data, supplemented by existing seismic test data, applied in accordance with the guidelines developed, can be used to verify the seismic adequacy of mechanical and electrical equipment in operating nuclear plants. Explicit seismic qualification should be required only if seismic experience data or existing test data on similar components cannot be shown to apply

  5. Evaluation of Electrical Characteristics of Protective Equipment - a Prerequisite for Ensuring Safety and Health of Workers at Work

    Science.gov (United States)

    Buică, G.; Beiu, C.; Antonov, A.; Dobra, R.; Păsculescu, D.

    2017-06-01

    The protecting electrical equipment in use are subject to various factors generated by the use, maintenance, storage and working environment, which may change the characteristics of protection against electric shock. The study presents the results of research on the behaviour over time of protective characteristics of insulating covers of material of work equipment in use, in order to determine the type and periodicity of safety tests. There were tested and evaluated safety equipment with plastic and insulating rubber covers used in operations of verifying functionality, safety and maintenance of machinery used in manufacturing industries and specific services from electric, energy and food sector.

  6. Development of a handmade device for collimation and central ray alignment tests in medical X-ray equipment

    International Nuclear Information System (INIS)

    Cruz, B.L. da; Brito, E.B.; Gomes, A.S.

    2017-01-01

    Ordinance 453/98 of the Ministry of Health establishes that medical X-ray equipment should be monitored by tests that prove its efficiency. This practice is called quality control (QC), and two important tests jointly evaluate the operation of the collimation and alignment systems of the central axis of the X-ray beam. The low supply and the high cost generate allegations of difficulties in the periodic realization of the tests. The aim of this work is to design, make and evaluate the performance of a handmade device for the mentioned tests, using low cost materials. Once built, the device had its performance evaluated and compared with the traditionally marketed device. The handmade device proved to be fit in its functions. It is possible to make a device that tests X-ray medical equipment, using the radiology technologist himself as the test runner. Radiation protection is promoted and legislation with no real financial burden

  7. Interim safety equipment list for 241-C-106 waste retrieval, project W-320

    International Nuclear Information System (INIS)

    Conner, J.C.

    1996-01-01

    The purpose of this supporting document is to provide safety classifications for systems, structures, and components of the Tank 241-C-106 Waste Retrieval Sluicing System (WRSS) and to document the methodology used to develop these safety classifications. The WRSS requires two transfer lines, one to carry sluiced waste slurry to tank 241-AY-102 and the other to return supernatant to tank 241-C-106; pumps in each tank; sluicers to direct the supernatant stream inside tank 241-C-106; a slurry distributor in tank 241-AY-102; heating, ventilation, and air conditioning for tank 241-C-106; and instrumentation and control devices

  8. Interim safety equipment list for 241-C-106 waste retrieval, project W-320

    Energy Technology Data Exchange (ETDEWEB)

    Conner, J.C.

    1996-01-25

    The purpose of this supporting document is to provide safety classifications for systems, structures, and components of the Tank 241-C-106 Waste Retrieval Sluicing System (WRSS) and to document the methodology used to develop these safety classifications. The WRSS requires two transfer lines, one to carry sluiced waste slurry to tank 241-AY-102 and the other to return supernatant to tank 241-C-106; pumps in each tank; sluicers to direct the supernatant stream inside tank 241-C-106; a slurry distributor in tank 241-AY-102; heating, ventilation, and air conditioning for tank 241-C-106; and instrumentation and control devices.

  9. On the preparation of fire-wood splitting machines equipped with feeder devices

    International Nuclear Information System (INIS)

    Jaeaeskelaeinen, M.

    1995-01-01

    As part of the Bionergy research programme, the TTS Institute's Department of Forestry conducted a study on firewood splitting machines manufactured by Bilke Oy and Peurala Oy. The said machines are the first of their kind in Finland to be equipped with a feeder device. The Bilke unit is fed by a conveyor belt arrangement while the Peurala unit is equipped with a feeder roll. In addition, both machine types are equipped with a conveyor belt discharging device (e.g. for discharging split wood directly into a trailer). The Bilke unit can also be operated on extraction racks in the woods as the stems due to be split are fed into it from the side and the conveyor discharges the split wood rearwards into the trailer. The trailer can be hooked onto the splitting unit's draw-hook. At the landing, the Bilke unit was used to split a total of 14.2 m 3 and the Peurala unit 8.0 m 3 of approx. 3-metrelong stems averaging 9 cm in diameter. In addition to this, the Bilke unit was used to split ca. 17 m 3 of 3.5 metre-long stems with on average diameter of ca. 6 cm; the stems were in bunches alongside the extraction racks. The person operating the machines for the purposes of this study was a 27-year- old forest worker. The mean productivity achieved at the landing when using the Bilke unit was 7.7 m 3 while that of the Peurala unit was 5.8 m 3 per effective hour. When operated in the woods, the productivity achieved with the Bilke unit (excluding felling-cross cutting-delimbing-bunching and forest haulage work) was 2.8 m 3 /h. When applying a productivity of 1.7 m 3 for felling-cross cutting- delimbing-bunching work and 5.5. m 3 for forest haulage, the entire harvesting chain's productivity was 0.9 m 3 per effective hour

  10. Analysis of the steel braced frames equipped with ADAS devices under the far field records

    Directory of Open Access Journals (Sweden)

    Mahmoud Bayat

    Full Text Available The usefulness of supplementary energy dissipation devices is now quite well-known in earthquake structural engineering for reducing the earthquake-induced response of structural systems. The seismic behavior of structures with supplemental ADAS devices is concerned in this study. In this paper, the ratio of the hysteretic energy to input energy is compared in different structural systems. The main purpose of this paper is to evaluate the behavior of structures equipped with yielding dampers (ADAS, located in far fields based on energy concepts. In order to optimize their seismic behavior, the codes and solutions are also presented. Three cases including five, ten and fifteen-story three-bay Concentric Braced Frames (CBF with and without ADAS were selected. The PERFORM 3D.V4 software along with three earthquake records (Northridge, Imperial Valley and Tabas is used for nonlinear time history analysis and the conclusions are drawn upon energy criterion. The effect of PGA variation and height of the frames are also considered in the study. Finally, to increase the energy damping ability and reduce the destructive effects in structures on an earthquake event, so that a great amount of induced energy is damped and destruction of the structure is prevented as much as possible by using ADAS dampers.

  11. Functionality of road safety devices – identification and analysis of factors

    Directory of Open Access Journals (Sweden)

    Jeliński Łukasz

    2017-01-01

    Full Text Available Road safety devices are designed to protect road users from the risk of injury or death. The principal type of restraint is the safety barrier. Deployed on sites with the highest risk of run-off-road accidents, safety barriers are mostly found on bridges, flyovers, central reservations, and on road edges which have fixed obstacles next to them. If properly designed and installed, safety barriers just as other road safety devices, should meet a number of functional features. This report analyses factors which may deteriorate functionality, ways to prevent this from happening and the thresholds for loss of road safety device functionality.

  12. Shields calculations for teletherapy equipment. Regulatory approach of the National Center of Nuclear Safety

    International Nuclear Information System (INIS)

    Fuente P, A. de la; Dumenigo G, C.; Quevedo G, J.R.; Lopez F, Y.

    2006-01-01

    The evaluation of applications of construction licenses for the new services of radiotherapy has occupied a significant space in the activity developed by the National Center of Nuclear Safety (CNSN) in the last 2 years. Presently work the experiences of the authors in the evaluation of the required shield for the local where cobalt therapy equipment and lineal accelerators of medical use are used its are exposed, the practical problems detected are approached during the application of the methodologies recommended in both cases and its are discussed which have been the suppositions of items accepted by the Regulatory Authority for the realization of these shield calculations. The accumulated experience allows to assure that the realistic application of the item data and the rational use of the engineering logic makes possible to design local for radiotherapy equipment that fulfill the established dose restrictions in the in use legislation in Cuba, without it implies an excessive expense of construction materials. (Author)

  13. Safety of information in electronic equipment influenced by the charged space particles

    Directory of Open Access Journals (Sweden)

    Ksenia Gennad’evna Sizova

    2016-10-01

    Full Text Available A version of the existing evaluation method of electronic equipment to the influence of charged space particles causing single event effects for the purpose of improving the accuracy of calculation in the field of information safety is suggested. On the basis of the existing and modified methods radiation tolerance of real payload spacecraft responsible for the security of transmitted information are defined. The results of comparison are introduced. Significant differences not only in quantitative but also in qualitative character of tolerance indicators are revealed. It is demonstrated that the modified method allows to take into account the functional complexity of the hardware and the application efficiency of the sophisticated single event effects protection tools. To confirm the applicability of the modified method of equipment tolerance evaluation method to the influence of charged space particles causing single event effects proposals to the procedure of ground tests of the payload and the space experiment are developed.

  14. 78 FR 29392 - Embedded Digital Devices in Safety-Related Systems, Systems Important to Safety, and Items Relied...

    Science.gov (United States)

    2013-05-20

    ... NUCLEAR REGULATORY COMMISSION [NRC-2013-0098] Embedded Digital Devices in Safety-Related Systems, Systems Important to Safety, and Items Relied on for Safety AGENCY: Nuclear Regulatory Commission. ACTION... (NRC) is issuing for public comment Draft Regulatory Issue Summary (RIS) 2013-XX, ``Embedded Digital...

  15. RESULTS OF THE SURVEY CONDUCTED AMONG OPHTHALMOLOGISTS ON THE ISSUE OF EQUIPMENT OF MEDICAL INSTITUTIONS WITH OPHTHALMOLOGY DEVICES

    Directory of Open Access Journals (Sweden)

    S. V. Seraphimov

    2017-01-01

    Full Text Available Introduction. The problem of limited accessibility and quality of ophthalmic medical care remains one of the leading ones in the national healthcare. This article presents results of the survey conducted among ophthalmologists about the effect of large-scale equipment of all medical institutions in the Leningrad Region with modern ophthalmologic devices over the recent years.Objective is to determine the contribution of the health care modernization program to equipping the medical institutions of the Leningrad Region with modern ophthalmologic medical devices, and to identify the main areas for improving the ophthalmologic care for residents of the Leningrad region with cataracts.Materials and methods. According to a specially developed questionnaire, 105 ophthalmologists from the Leningrad Region were interviewed. The survey was conducted among physicians working both in out-patient medical facilities and in medical facilities with in-patient modalities.Results. The results of the study confirmed positive changes that occurred in recent years as a result of equipping medical institutions with modern medical devices. Almost two-thirds (59.9% of respondents noted that equipping with modern medical devices had a significant impact on the quality of the medical and diagnostic measures carried out in healthcare facilities of the region.Conclusions. The equipment had a significant impact on the diagnosis and treatment of all kinds of diseases of the eye and its appendages, especially such eye disease which is so common among the population of the Leningrad Region as cataracts (75.0 per 100 ophthalmologists surveyed. At the same time, in spite of these efforts, the standard for equipping ophthalmologic departments in individual medical institutions has not been fully provided. Only every fifth (20.9% ophthalmologist noted during the survey that the list of available ophthalmic devices was sufficient, and that they all worked properly.

  16. The Design of Transportation Equipment in Terms of Human Capabilities. The Role of Engineering Psychology in Transport Safety.

    Science.gov (United States)

    McFarland, Ross A.

    Human factors engineering is considered with regard to the design of safety factors for aviation and highway transportation equipment. Current trends and problem areas are identified for jet air transportation and for highway transportation. Suggested solutions to transportation safety problems are developed by applying the techniques of human…

  17. Safety analysis and evaluation of the next fusion device

    International Nuclear Information System (INIS)

    Kobayashi, Shigetada; Honda, Tsutomu; Ohmura, Hiroshi; Kawai, Masayoshi; Shimizu, Takeshi; Yamaoka, Mitsuaki; Nakahara, Katsuhiko; Seki, Yasushi.

    1988-12-01

    As a part of safety evaluation, a probabilistic risk assessment (PRA) has been attempted for the Next Fusion Device system. Among the various events related to safety, a number of representative events have been selected for assessment, from the events in normal operation state, repair and maintenance state and accidental state. In the first chapter, in order to conduct the probabilistic risk assessment of the whole Fusion Experimental Reactor (FER), the data base required for the analysis was investigated in 1.1, the results on the failure mode and effects analysis (FMEA), accident sequence, radioactive inventory leakage flow path, event tree analysis (ETA) and fault tree analysis (FTA) were summarized in 1.2 to 1.5, respectively. Based on these results, accident initiating events were evaluated in 1.6, and overall risk was assessed in 1.7 and the tasks for the future were summarized in 1.8. It is important to analyze and evaluate various events during normal operations, repair and maintenance and accidents. However, due to the large uncertainties in the modeling of phenomena or the data base, there are many events for which realistic analyses are difficult. Three such events were selected and studied in chapter two. In 2.1, the temperature rise in the reactor structure after the Loss-of-Coolant-Accident caused by the decay heat under various heat removal conditions were investigated. In 2.2, the radiation dose of personnel during repair and maintenance period caused by the release of activated dust were estimated. Lastly, in 2.3 tritium behavior in the stainless steel first wall and graphite armour were studied. (author)

  18. Resolution of Unresolved Safety Issue A-48, ''Hydrogen control measures and effects of hydrogen burns on safety equipment''

    International Nuclear Information System (INIS)

    Ferrell, C.M.; Soffer, L.

    1989-09-01

    Unresolved Safety Issue (USI) A-48 arose as a result of the large amount of hydrogen generated and burned within containment during the Three Mile Island accident. This issue covers hydrogen control measures for recoverable degraded-core accidents for all boiling-water reactors (BWRs) and those pressurized-water reactors (PWRs) with ice-condenser containments. The Commission and the nuclear industry have sponsored extensive research in this area, which has led to significant revision of the Commission's hydrogen control regulations, given in Title 10, Code of Federal Regulations, Part 50 (10 CFR 50), Section 50.44. BWRs having Mark I and II containments are presently required to operate with inerted containment atmospheres that effectively prevent hydrogen combustion. BWRs with Mark III containments and PWRs with ice-condenser containments are now required to be equipped with hydrogen control systems to protect containment integrity and safety systems inside containment. Industry has chosen to use hydrogen igniter systems to burn hydrogen produced in a controlled fashion to prevent damage. An independent review by a Committee of the National Research Council concluded that, for most accident scenarios, current regulatory requirements make it highly unlikely that hydrogen detonation would be the cause of containment failure. On the basis of the extensive research effort conducted and current regulatory requirements, including their implementation, the staff concludes that no new regulatory guidance on hydrogen control for recoverable degraded-core accidents for these types of plants is necessary and that USI A-48 is resolved

  19. Equipment Qualification and Environment Establishment for COTS Dedication of Safety Grade PC

    International Nuclear Information System (INIS)

    Ahn, Kwang Chul; Bin, Chang Sun; Kwon, Yoon Kwang; Kang, Shin Woo; Koh, Sung Won; Shon, Eui Chan; Jang, Hyun Doo; Song, Il Sup; Lee, Hyun Noh

    2010-08-01

    Safety grade PCs are required for protection systems of SKN 3 and 4 nuclear power plant and subsequent plants. Commercial grade item (CGI) dedication should be carried out to utilize a commercial PC as a safety grade PC of nuclear power plants. This project is aimed to perform the equipment qualification of the commercial PC, and review and improve the quality system of the PC supplier. As a result of the EQ for the CGI dedication, selected military PCs have passed the environment test, the seismic test, and the EMI test required for the digital controllers of nuclear plants. In addition, a walk-through of the quality system of the PC supplier, ISO 9001, was carried out and the quality system was improved. History data for the PC was gathered. As the analysis of the history data showed that operating experience time of the PC is longer than the plant life time, the history data could be used as an evidence of acceptance. After dedicated according to the CGI dedication process, military rugged PCs could be used for safety grade PCs

  20. Study concerning the power plant control and safety equipment by integrated distributed systems

    International Nuclear Information System (INIS)

    Optea, I.; Oprea, M.; Stanescu, P.

    1995-01-01

    The paper deals with the trends existing in the field of nuclear control and safety equipment and systems, proposing a high-efficiency integrated system. In order to enhance the safety of the plant and reliability of the structure system and components, we present a concept based on the latest computer technology with an open, distributed system, connected by a local area network with high redundancy. A modern conception for the control and safety system is to integrate all the information related to the reactor protection, active engineered safeguard and auxiliary systems parameters, offering a fast flow of information between all the agencies concerned so that situations can be quickly assessed. The integrated distributed control is based on a high performance operating system for realtime applications, flexible enough for transparent networking and modular for demanding configurations. The general design considerations for nuclear reactors instrumentation reliability and testing methods for real-time functions under dynamic regime are presented. Taking into account the fast progress in information technology, we consider the replacement of the old instrumentation of Cernavoda-1 NPP by a modern integrated system as an economical and efficient solution for the next units. (Author) 20 Refs

  1. Evaluation of safety requirements of erbium laser equipment used in dentistry; Avaliacao de requisitos de seguranca de um equipamento a laser de erbio para fins odontologicos

    Energy Technology Data Exchange (ETDEWEB)

    Braga, Flavio Hamilton

    2002-07-01

    The erbium laser (Er:YAG) has been used in several therapeutic processes. Erbium lasers, however, operate with energies capable to produce lesions in biological tissues. Aiming the safe use, the commercialization of therapeutic laser equipment is controlled in Brazil, where the equipment should comply with quality and safety requirement prescribed in technical regulations. The objective of this work is to evaluate the quality and safety requirements of a commercial therapeutic erbium laser according to Brazilian regulations, and to discuss a risk control program intended to minimize the accidental exposition at dangerous laser radiation levels. It was verified that the analyzed laser can produce lesions in the skin and eyes, when exposed to laser radiation at distances smaller than 80 cm by 10 s or more. In these conditions, the use of protection glasses is recommended to the personnel that have access to the laser operation ambient. It was verified that the user's training and the presence of a target indicator are fundamental to avoid damages in the skin and buccal cavity. It was also verified that the knowledge and the correct use of the equipment safety devices, and the application of technical and administrative measures is efficient to minimize the risk of dangerous expositions to the laser radiation. (author)

  2. Safety evaluation in the development of medical devices and combination products

    CERN Document Server

    Gad, Shayne C

    2008-01-01

    Capturing the growth of the global medical device market in recent years, this practical new guide is essential for all who are responsible for ensuring safety in the use and manufacture of medical devices. It has been extensively updated to reflect significant advances, incorporating combination products and helpful case examples of current real-life problems in the field.The Third Edition explores these key current trends:global device marketscontinually advancing technologythe increasing harmonization of device safety regulation worldwideEach aspect of safety evaluation is considered in ter

  3. Decree No85-968 of 27 August 1986 amending Article R.233-83 of the Labour Code and defining the health and safety conditions to be met by gamma industrial radiography equipment

    International Nuclear Information System (INIS)

    1986-01-01

    This Decree, amending Article R 233-83 of the Labour Code, applies to gamma-ray industrial radiography equipment whether mobile or fixed. It contains specific technical conditions concerning the equipment, in particular, safety devices located at the entry and exit points of the source's shield. The equipment must carry a notice mentioning''Radioactive''prepared by the constructor or the importer of the source, which explains the conditions for handling, setting-up, use and maintenance of the source, including the frequency of revisions. The Decree entered into force on 1 June 1986. (NEA) [fr

  4. Safety evaluation for packaging transportation of equipment for tank 241-C-106 waste sluicing system

    International Nuclear Information System (INIS)

    Calmus, D.B.

    1994-01-01

    A Waste Sluicing System (WSS) is scheduled for installation in nd waste storage tank 241-C-106 (106-C). The WSS will transfer high rating sludge from single shell tank 106-C to double shell waste tank 241-AY-102 (102-AY). Prior to installation of the WSS, a heel pump and a transfer pump will be removed from tank 106-C and an agitator pump will be removed from tank 102-AY. Special flexible receivers will be used to contain the pumps during removal from the tanks. After equipment removal, the flexible receivers will be placed in separate containers (packagings). The packaging and contents (packages) will be transferred from the Tank Farms to the Central Waste Complex (CWC) for interim storage and then to T Plant for evaluation and processing for final disposition. Two sizes of packagings will be provided for transferring the equipment from the Tank Farms to the interim storage facility. The packagings will be designated as the WSSP-1 and WSSP-2 packagings throughout the remainder of this Safety Evaluation for Packaging (SEP). The WSSP-1 packagings will transport the heel and transfer pumps from 106-C and the WSSP-2 packaging will transport the agitator pump from 102-AY. The WSSP-1 and WSSP-2 packagings are similar except for the length

  5. 77 FR 35745 - Highway Safety Programs; Conforming Products List of Screening Devices To Measure Alcohol in...

    Science.gov (United States)

    2012-06-14

    ..., battery powered device with a semiconductor sensor. (2) Alcohol Countermeasure Systems Corp., submitted...-0062] Highway Safety Programs; Conforming Products List of Screening Devices To Measure Alcohol in... Screening Devices to Measure Alcohol in Bodily Fluids dated, March 31, 2008 (73 FR 16956). DATES: Effective...

  6. Synergistic behaviour of nuclear radiation, temperature-humidity extremes and LOCA situation on safety and safety-related equipment in Indian nuclear power plants

    International Nuclear Information System (INIS)

    Kulkarni, R.D.; Bora, J.S.; Prakash, Ravi; Agarwal, Vivek; Sundersingh, V.P.

    2002-01-01

    Full text: The general philosophy for the instrumentation in nuclear power plants is based on the use of equipment/instruments which are capable of continuous satisfactory operation over a long period of time with minimum attention. Long term reliability under varying service conditions is of prime importance. The reliability of nuclear power plant depends on the reliability of safety and safety-related electronic instruments/ equipment used for performing the crucial tasks. The electrical and electronic systems/ circuits/ components of the equipment used in reactor safety systems (e.g. reactor protection system, emergency core cooling system, etc.) and reactor safety-related systems (e.g. reactor containment isolation and cooling system, reactor shutdown system, etc.) are responsible for safe and reliable operation of a nuclear power plant. The performance of reactor safety and safety-related equipment/instruments viz. pressure and differential pressure transmitter, amplifier for ion chamber, etc. has been evaluated under synergistic atmosphere including LOCA to find out the critical link in the circuits and subsequent modifications are suggested. The mathematical representation of the generated database has been done to estimate the life span of the instruments and accordingly the guidelines has been prepared for the operational staff to avoid the forced outage of the plant. All the details are included and mathematical models are presented to predict the future performances

  7. Technical basis for environmental qualification of microprocessor-based safety-related equipment in nuclear power plants

    International Nuclear Information System (INIS)

    Korsah, K.; Wood, R.T.; Hassan, M.; Tanaka, T.J.

    1998-01-01

    This document presents the results of studies sponsored by the Nuclear Regulatory Commission (NRC) to provide the technical basis for environmental qualification of computer-based safety equipment in nuclear power plants. The studies were conducted by Oak Ridge National Laboratory (ORNL), Sandia National Laboratories (SNL), and Brookhaven National Laboratory (BNL). The studies address the following: (1) adequacy of the present test methods for qualification of digital I and C systems; (2) preferred (i.e., Regulatory Guide-endorsed) standards; (3) recommended stressors to be included in the qualification process during type testing; (4) resolution of need for accelerated aging for equipment to be located in a benign environment; and (5) determination of an appropriate approach for addressing the impact of smoke in digital equipment qualification programs. Significant findings from the studies form the technical basis for a recommended approach to the environmental qualification of microprocessor-based safety-related equipment in nuclear power plants

  8. Technical basis for environmental qualification of microprocessor-based safety-related equipment in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Korsah, K.; Wood, R.T. [Oak Ridge National Lab., TN (United States); Hassan, M. [Brookhaven National Lab., Upton, NY (United States); Tanaka, T.J. [Sandia National Labs., Albuquerque, NM (United States)

    1998-01-01

    This document presents the results of studies sponsored by the Nuclear Regulatory Commission (NRC) to provide the technical basis for environmental qualification of computer-based safety equipment in nuclear power plants. The studies were conducted by Oak Ridge National Laboratory (ORNL), Sandia National Laboratories (SNL), and Brookhaven National Laboratory (BNL). The studies address the following: (1) adequacy of the present test methods for qualification of digital I and C systems; (2) preferred (i.e., Regulatory Guide-endorsed) standards; (3) recommended stressors to be included in the qualification process during type testing; (4) resolution of need for accelerated aging for equipment to be located in a benign environment; and (5) determination of an appropriate approach for addressing the impact of smoke in digital equipment qualification programs. Significant findings from the studies form the technical basis for a recommended approach to the environmental qualification of microprocessor-based safety-related equipment in nuclear power plants.

  9. Manual on safety aspects of the design and equipment of hot laboratories. 1981 ed

    International Nuclear Information System (INIS)

    1981-01-01

    This manual covers the general principles of planning and design of areas inside laboratories according to the varying potential radiation and contamination hazards; enclosures for radioactive material containment; viewing and lighting systems and various types of manipulators; transfer and transport of radioactive materials within the laboratories; air cleaning and ventilation systems, with particular reference to IAEA Safety Series No.17; techniques for controlling air pollution from the operation of nuclear facilities; various radioactive waste disposal systems; criticality control; fire protection; personnel monitoring, including changing-room monitoring and protective clothing; standardization and automation; and administrative controls. Although alpha, beta, gamma technologies have developed separately, equipment used in radioactive work is common to many operations. There is a step change in technology between work with uranium and plutonium and between work with plutonium and other transuranics; with plutonium one enters the field of alpha, beta, gamma technology. This manual reports the basic requirements and gives reference to more sophisticated techniques available. It is not concerned with work on a commercial scale. Other publications of interest in this context, for instance IAEA Safety Series No.39, are referenced for more detailed information.

  10. Just a piece of equipment? The importance of medical device education.

    Science.gov (United States)

    Brand, Darren

    2012-12-01

    The use of medical devices is an increasingly important element of a healthcare professional's role. It is crucial that users receive regular teaching and education to ensure that they are competent in the use of devices. This is particularly relevant in the increasingly litigious society in which we live. This article focuses upon the importance of a medical device education.

  11. Guidelines for evaluation of anchorage adequacy for safety-related equipment typically used on WWER-type NPPs

    International Nuclear Information System (INIS)

    Masopust, R.

    1999-01-01

    This report describes the criteria which should be met when the capacity evaluation of anchorage of safety related equipment is performed for the WWER type NPPs. It should be noted that these criteria were developed specifically for anchorage of WWER type equipment and components to the concrete or steel building structures and they cover different types of anchor bolts and other anchorage details which are typical just for the existing, constructed or reconstructed WWER type NPPs. The screening approach for verifying of equipment anchorage presented in this report is based on a combination of inspections, calculations, and engineering judgement

  12. Study on a quantitative evaluation method of equipment maintenance level and plant safety level for giant complex plant system

    International Nuclear Information System (INIS)

    Aoki, Takayuki

    2010-01-01

    In this study, a quantitative method on maintenance level which is determined by the two factors, maintenance plan and field work implementation ability by maintenance crew is discussed. And also a quantitative evaluation method on safety level for giant complex plant system is discussed. As a result of consideration, the following results were obtained. (1) It was considered that equipment condition after maintenance work was determined by the two factors, maintenance plan and field work implementation ability possessed by maintenance crew. The equipment condition determined by the two factors was named as 'equipment maintenance level' and its quantitative evaluation method was clarified. (2) It was considered that CDF in a nuclear power plant, evaluated by using a failure rate counting the above maintenance level was quite different from CDF evaluated by using existing failure rates including a safety margin. Then, the former CDF was named as 'plant safety level' of plant system and its quantitative evaluation method was clarified. (3) Enhancing equipment maintenance level means an improvement of maintenance quality. That results in the enhancement of plant safety level. Therefore, plant safety level should be always watched as a plant performance indicator. (author)

  13. Comparing non-safety with safety device sharps injury incidence data from two different occupational surveillance systems.

    Science.gov (United States)

    Mitchell, A H; Parker, G B; Kanamori, H; Rutala, W A; Weber, D J

    2017-06-01

    The United States Occupational Safety and Health Administration (OSHA) Bloodborne Pathogens Standard as amended by the Needlestick Safety and Prevention Act requiring the use of safety-engineered medical devices to prevent needlesticks and sharps injuries has been in place since 2001. Injury changes over time include differences between those from non-safety compared with safety-engineered medical devices. This research compares two US occupational incident surveillance systems to determine whether these data can be generalized to other facilities and other countries either with legislation in place or considering developing national policies for the prevention of sharps injuries among healthcare personnel. Copyright © 2017 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  14. Design of Hack-Resistant Diabetes Devices and Disclosure of Their Cyber Safety.

    Science.gov (United States)

    Sackner-Bernstein, Jonathan

    2017-03-01

    The focus of the medical device industry and regulatory bodies on cyber security parallels that in other industries, primarily on risk assessment and user education as well as the recognition and response to infiltration. However, transparency of the safety of marketed devices is lacking and developers are not embracing optimal design practices with new devices. Achieving cyber safe diabetes devices: To improve understanding of cyber safety by clinicians and patients, and inform decision making on use practices of medical devices requires disclosure by device manufacturers of the results of their cyber security testing. Furthermore, developers should immediately shift their design processes to deliver better cyber safety, exemplified by use of state of the art encryption, secure operating systems, and memory protections from malware.

  15. Description of the microbial ecology evaluation device, flight equipment, and ground transporter

    Science.gov (United States)

    Chassay, C. E.; Taylor, G. R.

    1973-01-01

    Exposure of test systems in space required the fabrication of specialized hardware termed a Microbial Ecology Evaluation Device that had individual test chambers and a complex optical filter system. The characteristics of this device and the manner in which it was deployed in space are described.

  16. Shielding of the 9 TW pulse thermonuclear device equipment from electromagnetic noise

    International Nuclear Information System (INIS)

    Zajtsev, V.I.; Kopyrina, R.I.; Kostromin, A.P.; Olejnik, G.M.

    1990-01-01

    A complex of technical solutions providing for reliable noise-immunity of information-measuring systems, is realized at the ANGARA-5 device. The main method of noise elimination consists in the measurement system shielding and careful wiring of various conductors through the shield. The level of noises connected with the device operation does not exceed 30 mV

  17. Inherent Risk or Risky Decision? Coach's Failure to Use Safety Device an Assumed Risk

    Science.gov (United States)

    Dodds, Mark A.; Bochicchio, Kristi Schoepfer

    2013-01-01

    The court examined whether a coach's failure to implement a safety device during pitching practice enhanced the risk to the athlete or resulted in a suboptimal playing condition, in the context of the assumption of risk doctrine.

  18. IE Information Notice No. 85-08: Industry experience on certain materials used in safety-related equipment

    International Nuclear Information System (INIS)

    Jordan, E.L.

    1992-01-01

    This information notice is being issued to provide licensees and construction permit holders with information pertaining to the behavior of certain materials used in safety-related equipment. The materials, as described below, were observed to have the potential of degrading the operability of safety-related equipment. These observations were made during environmental qualification testing and/or during routine inspection of in-service equipment. The notice describes the following: elastomeric seals used in personnel air locks for the reactor containment systems; epoxy phenolic coating applied to the lower portion of the interior surface of diesel oil storage tanks; the use of Viton elastomer as the seal material in hydrogen recombiner applications; and environmental qualification of ASCO NP valves with Viton and ethylene propylene parts

  19. Evaluation of the Safety of the Taraklamp Male Circumcision Device ...

    African Journals Online (AJOL)

    SITWALA COMPUTERS

    an effective additional means of preventing transmission of the HIV virus from ... country and include: cultural tradition, pain, and safety, as ... effective. Thus, the World Health Organization (WHO) has ..... systematic review and meta-analysis.

  20. Disinfection protocols for necropsy equipment in rabies laboratories: Safety of personnel and diagnostic outcome.

    Science.gov (United States)

    Aiello, Roberta; Zecchin, Barbara; Tiozzo Caenazzo, Silvia; Cattoli, Giovanni; De Benedictis, Paola

    2016-08-01

    In the last decades, molecular techniques have gradually been adopted for the rapid confirmation of results obtained through gold standard methods. However, international organisations discourage their use in routine laboratory investigations for rabies post-mortem diagnosis, as they may lead to false positive results due to cross-contamination. Cleaning and disinfection are essential to prevent cross-contamination of samples in the laboratory environment. The present study evaluated the efficacy of selected disinfectants on rabies-contaminated necropsy equipment under organic challenge using a carrier-based test. The occurrence of detectable Rabies virus (RABV) antigen, viable virus and RNA was assessed through the gold standard Fluorescent Antibody Test, the Rabies Tissue Culture Infection Test and molecular techniques, respectively. None of the tested disinfectants proved to be effective under label conditions. Off label disinfection protocols were found effective for oxidizing agents and phenolic, only. Biguanide and quaternary ammonium compound were both ineffective under all tested conditions. Overall, discordant results were obtained when different diagnostic tests were compared, which means that in the presence of organic contamination common disinfectants may not be effective enough on viable RABV or RNA. Our results indicate that an effective disinfection protocol should be carefully validated to guarantee staff safety and reliability of results. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  1. A device for reduction of metal oxides generated in electrokinetic separation equipment

    International Nuclear Information System (INIS)

    Kim, Gye-Nam; Kim, Seung-Soo; Kim, Il-Gook; Jeong, Jung-Whan; Choi, Jong-Won

    2015-01-01

    For a reduction of waste electrolyte volume and metal oxide volume, the reuse period of the waste electrolyte in the electrokinetic decontamination experiment and the method of a reduction of metal oxide volume in the cathode chamber were drawn out through several experiments with the manufactured 1.2 ton electrokinetic decontamination equipment. The optimum pH of electrolyte in cathode chamber for a reduction of volume of metal oxides was below 2.35. Indoor electrokinetic decontamination equipment for treatment of 1.2 tons of the contaminated soil per batch was manufactured to remove uranium from soil with high removal efficiency during a short time. For a reduction of waste electrolyte volume and metal oxide volume, the reuse period of waste electrolyte in the electrokinetic decontamination experiment and the method of a reduction of metal oxide volume in the cathode chamber were drawn out through several experiments with the manufactured electrokinetic equipment. Indoor electrokinetic decontamination equipment for treatment of 1.2 tons of the contaminated soil was manufactured to remove uranium from soil during a short time

  2. A device for reduction of metal oxides generated in electrokinetic separation equipment

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Gye-Nam; Kim, Seung-Soo; Kim, Il-Gook; Jeong, Jung-Whan; Choi, Jong-Won [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2015-10-15

    For a reduction of waste electrolyte volume and metal oxide volume, the reuse period of the waste electrolyte in the electrokinetic decontamination experiment and the method of a reduction of metal oxide volume in the cathode chamber were drawn out through several experiments with the manufactured 1.2 ton electrokinetic decontamination equipment. The optimum pH of electrolyte in cathode chamber for a reduction of volume of metal oxides was below 2.35. Indoor electrokinetic decontamination equipment for treatment of 1.2 tons of the contaminated soil per batch was manufactured to remove uranium from soil with high removal efficiency during a short time. For a reduction of waste electrolyte volume and metal oxide volume, the reuse period of waste electrolyte in the electrokinetic decontamination experiment and the method of a reduction of metal oxide volume in the cathode chamber were drawn out through several experiments with the manufactured electrokinetic equipment. Indoor electrokinetic decontamination equipment for treatment of 1.2 tons of the contaminated soil was manufactured to remove uranium from soil during a short time.

  3. 49 CFR 571.108, Nt. - Standard No. 108; Lamps, reflective devices, and associated equipment.

    Science.gov (United States)

    2010-10-01

    ... subparagraph (f) of this paragraph, and after cooling to room ambient temperature, a test specimen shall show....4Except for multifunction school activity buses, each school bus shall be equipped with a system of either: (a) Four red signal lamps designed to conform to SAE Standard J887, School Bus Red Signal Lamps, July...

  4. 47 CFR 2.803 - Marketing of radio frequency devices prior to equipment authorization.

    Science.gov (United States)

    2010-10-01

    ... advised in writing at the time of the offer for sale that the equipment is subject to the FCC rules and... authority of a local FCC licensed service provider. However, the licensee must grant permission to the... party has the product measured to ensure compliance at the end user's location, the product does not...

  5. Electronic Equipment of Self-Actuated Mobile Device for Load Carrying

    Directory of Open Access Journals (Sweden)

    T. Janecka

    1994-12-01

    Full Text Available The device dealt in this work is determined namely for carrying invalid persons on various types of stairs or other not flat surfaces. But it can serve also to other purposes.To enable fulfilling all given demands, the design was consulted with other research workers solving the tasks of similar features.Resulting mechanical device, enabling aspects of movement required, is controlled by electronic and microprocessor circuits that obtain the input information from sensitive units investigating the terrain.

  6. Comparison and Analysis of IEEE 344 and IEC 60980 standards for harmonization of seismic qualification of safety-related equipment

    International Nuclear Information System (INIS)

    Lee, Young Ok; Kim, Jong Seog; Seo, Jeong Ho; Kim, Myung Jun

    2011-01-01

    The seismic qualification of safety related equipment in nuclear power plants should demonstrate an equipment's ability to perform its safety function during/or after the time it is subjected to the forces resulting from one SSE. In addition, the equipment must withstand the effects of a number of OBEs, preceding the SSE. IEEE 344 and IEC 60980 present the criteria for establishing procedures demonstrating that the Class 1E equipment can meet its performance requirement during seismic events. Currently, IEEE 344 is used for regulation of nuclear power plant in the United State whereas IEC 60980 is mainly used in Europe. In particular, NPPs of France and China apply with RCC-E and GB that are domestic standards, respectively. Equipment supplier and Utility have difficulties because of different applicable standards. Equipment supplier to export S/R components/equipment to other standard area performs additional seismic qualification. For example, equipment are qualifies according to IEC 60980, RCC-E, GB although they have been qualified in accordance with IEEE 344. Also, utility to attempt power up-rate, life extension of NPP constructed under rules of RCC-E such as Ulchin NPP 1 and 2 has similar difficulties. RCC-E endorses IEC 60980 and GB is almost same as IEC 60980 except minor difference of earthquake environment definition. Therefore this paper surveys the similarities and differences between IEEE 344 and IEC 60980. In addition, this paper considers how the two sets of standards may be used in a complementary fashion to be possible using one or the other standard area

  7. 78 FR 17415 - Medical Devices; Availability of Safety and Effectiveness Summaries for Premarket Approval...

    Science.gov (United States)

    2013-03-21

    ... its decision. The regulations provide that FDA publish a quarterly list of available safety and..., FDA-2012-M-1183, and FDA-2012-M-1184] Medical Devices; Availability of Safety and Effectiveness.... SUMMARY: The Food and Drug Administration (FDA) is publishing a list of premarket approval applications...

  8. 77 FR 60704 - Medical Devices; Availability of Safety and Effectiveness Summaries for Premarket Approval...

    Science.gov (United States)

    2012-10-04

    ... regulations provide that FDA publish a quarterly list of available safety and effectiveness summaries of PMA...-0638] Medical Devices; Availability of Safety and Effectiveness Summaries for Premarket Approval... Administration (FDA) is publishing a list of premarket approval applications (PMAs) that have been approved. This...

  9. 78 FR 35284 - Medical Devices; Availability of Safety and Effectiveness Summaries for Premarket Approval...

    Science.gov (United States)

    2013-06-12

    ... summaries of safety and effectiveness data to the Division of Dockets Management (HFA-305), Food and Drug... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket Nos. FDA-2013-M-0036... Devices; Availability of Safety and Effectiveness Summaries for Premarket Approval Applications AGENCY...

  10. 76 FR 31965 - Medical Devices; Availability of Safety and Effectiveness Summaries for Premarket Approval...

    Science.gov (United States)

    2011-06-02

    ... summaries of safety and effectiveness data to the Division of Dockets Management (HFA-305), Food and Drug... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket Nos. FDA-2011-M-0034... Devices; Availability of Safety and Effectiveness Summaries for Premarket Approval Applications AGENCY...

  11. Permitting product liability litigation for FDA-approved drugs and devices promotes patient safety.

    Science.gov (United States)

    Kesselheim, A S

    2010-06-01

    In 2008 and 2009, the Supreme Court reviewed the question of whether patients injured by dangerous prescription drugs or medical devices can bring tort lawsuits against pharmaceutical and device manufacturers. The Court ruled that claims against device manufacturers were preempted while claims against pharmaceutical manufacturers were not. The threat of product liability lawsuits promotes patient safety by encouraging manufacturers to take greater responsibility in providing clear warnings about known adverse effects of their products.

  12. Safety and efficiency of emergency department interrogation of cardiac devices.

    Science.gov (United States)

    Neuenschwander, James F; Peacock, W Frank; Migeed, Madgy; Hunter, Sara A; Daughtery, John C; McCleese, Ian C; Hiestand, Brian C

    2016-12-01

    Patients with implanted cardiac devices may wait extended periods for interrogation in emergency departments (EDs). Our purpose was to determine if device interrogation could be done safely and faster by ED staff. Prospective randomized, standard therapy controlled, trial of ED staff device interrogation vs. standard process (SP), with 30-day follow-up. Eligibility criteria: ED presentation with a self-report of a potential device related complaint, with signed informed consent. SP interrogation was by company representative or hospital employee. Of 60 patients, 42 (70%) were male, all were white, with a median (interquartile range) age of 71 (64 to 82) years. No patient was lost to follow up. Of all patients, 32 (53%) were enrolled during business hours. The overall median (interquartile range) ED vs. SP time to interrogation was 98.5 (40 to 260) vs. 166.5 (64 to 412) minutes (P=0.013). While ED and SP interrogation times were similar during business hours, 102 (59 to 138) vs. 105 (64 to 172) minutes (P=0.62), ED interrogation times were shorter vs. SP during non-business hours; 97 (60 to 126) vs. 225 (144 to 412) minutes, P=0.002, respectively. There was no difference in ED length of stay between the ED and SP interrogation, 249 (153 to 390) vs. 246 (143 to 333) minutes (P=0.71), regardless of time of presentation. No patient in any cohort suffered an unplanned medical contact or post-discharge adverse device related event. ED staff cardiac device interrogations are faster, and with similar 30-day outcomes, as compared to SP.

  13. Regulatory analysis for resolution of Unresolved Safety Issue A-46, seismic qualification of equipment in operating plants

    International Nuclear Information System (INIS)

    Chang, T.Y.; Anderson, N.R.

    1987-02-01

    The margin of safety provided in existing nuclear power plant equipment to resist seismically induced loads and perform required safety functions may vary considerably, because of significant changes in design criteria and methods for the seismic qualification of equipment over the years. Therefore, the seismic qualification of equipment in operating plants must be reassessed to determine whether requalification is necessary. The objective of technical studies performed under Task Action Plan A-46 was to establish an explicit set of guidelines and acceptance criteria to judge the adequacy of equipment under seismic loading at all operating plants, in lieu of requiring these plants to meet the criteria that are applied to new plants. This report presents the regulatory analysis for Unresolved Safety Issue (USI) A-46. It includes: Statement of the Problem; the Objective of USI A-46; a Summary of A-46 Tasks; a Proposed Implementation Procedure; a Value-Impact Analysis; Application of the Backfit Rule; 10 CFR 50.109; Implementation; and Operating Plants To Be Reviewed to USI A-46 Requirements

  14. Evaluation of the safety of the Taraklamp male circumcision device ...

    African Journals Online (AJOL)

    Background: Male circumcision has been proved to be an effective additional means of preventing transmission of the HIV virus from females to males in heterosexual relationships with efficacy of up to 60%. Many methods and devices for adult male circumcision have now been developed. However, there are still concerns ...

  15. 75 FR 45696 - Pipeline Safety: Personal Electronic Device Related Distractions

    Science.gov (United States)

    2010-08-03

    ... DEPARTMENT OF TRANSPORTATION Pipeline and Hazardous Materials Safety Administration [Docket No... and operators of natural gas and hazardous liquid pipeline facilities are required to have and follow.... Advisory Bulletin (ADB-10-06) To: Owners and Operators of Hazardous Liquid and Natural Gas Pipeline Systems...

  16. Situation analysis of physical independence of the equipment and safety circuits of Almaraz NPP regarding R.G. 1.75 rev.3 (2005)

    International Nuclear Information System (INIS)

    Seijas Portela, S.

    2010-01-01

    Situation analysis of physical independence of the electrical equipment and circuits CN safety Almaraz about R.G. 1.75 rev. 3. (2005) The aim of this paper is to present the work done in the analysis of the physical separation of redundant safety electrical equipment (emergency diesel generators, medium voltage, electrical cabinets, etc.) and physical separation of circuits and electrical conduits.

  17. Effects of safety climate on safety norm violations: exploring the mediating role of attitudinal ambivalence toward personal protective equipment.

    Science.gov (United States)

    Cavazza, Nicoletta; Serpe, Alessandra

    2009-01-01

    Research on the role of organizational and psychosocial factors in influencing risk behaviors and the likelihood of injury at work showed that safety climate also has great impact on workers' behavior. However, the mechanisms through which this impact operates are still partially unclear. In order to explore the role that attitudinal ambivalence toward wearing PPE might play in mediating the impact of safety climate on safety norm violations, a questionnaire was administered to 345 Italian workers. Three dimensions of safety climate (i.e., company safety concern, senior managers' safety concern, supervisors' attitudes towards safety) were found to be positively associated with the individual ambivalence level, whereas the fourth one (i.e., work pressure) was negatively correlated with it. In turn, low levels of ambivalence were associated with a lower tendency to break the safety norms, even though the perception of a good safety climate also maintained a direct effect on unsafe behaviors. Designers of training program for the prevention of work related injuries must pay great attention to the psycho-social factors (such as the effects of the safety climate perception by employees on their attitudes and behaviors), and include specific contents into the prevention programs in order to improve workers compliance with safety norms.

  18. Ionizing secondary radiation generated by analog radiological and digital coronary cine angiographic equipment. Influence of external protection devices

    International Nuclear Information System (INIS)

    Ramirez N, Alfredo; Farias Ch, Eric; Silva J, Ana Maria; Leyton L, Fernando; Oyarzun C, Carlos; Ugalde P, Hector; Dussaillant, Gaston; Cumsille G, Angel

    2000-01-01

    Exposure to ionizing radiation is a know hazard of radiological procedures. Aim: to compare the emission of secondary ionizing radiation from two coronary angiographic equipments, one with digital and the other with analog image generation. To evaluate the effectiveness of external radiological protection devices. Material and methods: environmental and fluoroscopy generated radiation in the cephalic region of the patient was measured during diagnostic coronary angiographies. Ionizing radiation generated in anterior left oblique protection (ALO) and anterior right oblique protection (ARO) were measured with and without leaded protections. In 19 patients (group 1), a digital equipment was used and in 21 (group 2), an analog equipment. Results: header radiation for group 1 and 2 was 1194±337 and 364±222 μGray/h respectively (p≤0.001). During fluoroscopy and with leaded protection generated radiation for groups 1 and 2 was 612±947 and 70±61μGray/h respectively (p≤0.001). For ALO projection, generated for groups 1 and 2 was 105±47 and 71±192 μGray/h respectively (p≤0.001). During filming the radiation for ALO projection for groups 1 and 2 was 7252±9569 and 1671±2038 μGray/h respectively (p=0.03). Out of the protection zone, registered radiation during fluoroscopy for groups 1 and 2 was 2800±1741 and 1318±954 μGray/h respectively (p≤0.001); during filming, the figures were 15500±5840 and 18961±10599 μGray/h respectively (NS). Conclusions: digital radiological equipment has a lower level of ionizing radiation emission than the analog equipment

  19. Artifical Excitation of Ferro-Resonance for Testing Electrotechnical Equipment in Distribution Devices with Increased Voltage

    Directory of Open Access Journals (Sweden)

    Ye. V. Dmitriev

    2006-01-01

    Full Text Available On the basis of the developed device for protection against of ferro-resonant and high-frequency cumulative over-voltages an algorithm for obtaining a voltage imitating ferro-resonant over-voltages is proposed in the paper. This algorithm presupposes to apply a voltage to the secondary transformer side from an extraneous source is proposed.

  20. Safety shutdowns and failures of the RA reactor equipment; Sigurnosna zaustavljanja i kvarovi opreme na reaktoru RA

    Energy Technology Data Exchange (ETDEWEB)

    Mitrovic, S [Institut za nuklearne nauke ' Boris Kidric' , Vinca, Belgrade (Yugoslavia)

    1966-07-01

    This report is an attempt of statistical analysis of the failures occurred during RA reactor operation. A list of failures occurred on the RA equipment during 1965 is included. Failures were related to the following systems: dosimetry system (22%), safety and control system (7%), heavy water system (2%), technical water (4%), helium system (2%), measuring instruments (30%), transport, ventilation, power supply systems (32%). A review of safety shutdowns from 1962 to 1966 is included as well, as a comparison with three similar reactors. Although the number of events used for statistical analysis was not adequate, it has been concluded that RA reactor operation was stable and reliable.

  1. 76 FR 78 - Federal Motor Vehicle Safety Standard; Engine Control Module Speed Limiter Device

    Science.gov (United States)

    2011-01-03

    ... [Docket No. NHTSA-2007-26851] Federal Motor Vehicle Safety Standard; Engine Control Module Speed Limiter... occupants. IIHS stated that on-board electronic engine control modules (ECM) will maintain the desired speed... be equipped with an electronic control module (ECM) that is capable of limiting the maximum speed of...

  2. In-use NOx emissions from model year 2010 and 2011 heavy-duty diesel engines equipped with aftertreatment devices.

    Science.gov (United States)

    Misra, Chandan; Collins, John F; Herner, Jorn D; Sax, Todd; Krishnamurthy, Mohan; Sobieralski, Wayne; Burntizki, Mark; Chernich, Don

    2013-07-16

    The California Air Resources Board (ARB) undertook this study to characterize the in-use emissions of model year (MY) 2010 or newer diesel engines. Emissions from four trucks: one equipped with an exhaust gas recirculation (EGR) and three equipped with EGR and a selective catalytic reduction (SCR) device were measured on two different routes with three different payloads using a portable emissions measurement system (PEMS) in the Sacramento area. Results indicated that brake-specific NOx emissions for the truck equipped only with an EGR were independent of the driving conditions. Results also showed that for typical highway driving conditions, the SCR technology is proving to be effective in controlling NOx emissions. However, under operations where the SCR's do not reach minimum operating temperature, like cold starts and some low load/slow speed driving conditions, NOx emissions are still elevated. The study indicated that strategies used to maintain exhaust temperature above a certain threshold, which are used in some of the newer SCRs, have the potential to control NOx emissions during certain low-load/slow speed driving conditions.

  3. Safety device and machine system of nuclear power plant

    International Nuclear Information System (INIS)

    1978-10-01

    It introduces principle and kinds of heat power including heat balance and nuclear power. It explains a lot of technical terms about the nuclear power system, which are primary loop, reactor, steam generator, primary coolant pump and pressurizer in PWR, chemical and volume control system, component cooling system, safety injection system, and spent fuel cooling and storage system in auxiliary system, liquid solid and gaseous waste disposal system in radwaste disposal, gland sealing system, turbine instrumentation, turning gear, hydrogen cooling system, condenser, feedwater heater, degenerate heater, auxiliary heat exchanger, centrifugal pump, rotary reciprocating and tank and pressure vessel.

  4. Safety equipment list for the 241-SY-101 RAPID mitigation project

    International Nuclear Information System (INIS)

    Morris, K.L.

    1999-01-01

    This document provides the safety classification for the safety (safety class and safety RAPID Mitigation Project. This document is being issued as the project SEL until the supporting authorization basis documentation, this document will be superseded by the TWRS SEL (LMHC 1999), documentation istlralized. Upon implementation of the authorization basis significant) structures, systems, and components (SSCS) associated with the 241-SY-1O1 which will be updated to include the information contained herein

  5. Safety equipment list for the 241-SY-101 RAPID mitigation project

    Energy Technology Data Exchange (ETDEWEB)

    MORRIS, K.L.

    1999-06-29

    This document provides the safety classification for the safety (safety class and safety RAPID Mitigation Project. This document is being issued as the project SEL until the supporting authorization basis documentation, this document will be superseded by the TWRS SEL (LMHC 1999), documentation istlralized. Upon implementation of the authorization basis significant) structures, systems, and components (SSCS) associated with the 241-SY-1O1 which will be updated to include the information contained herein.

  6. Seismic qualification of equipment in operating nuclear power plants. Unresolved safety issue A-46, draft report for comment

    International Nuclear Information System (INIS)

    Chang, T.Y.

    1985-08-01

    The margin of safety provided in existing nuclear power plant equipment to resist seismically induced loads and perform their intended safety functions may vary considerably, because of significant changes in design criteria and methods for the seismic qualification of equipment over the years. Therefore, the seismic qualification of equipment in operating plants should be reassessed to determine whether requalification is necessary. The objective of technical studies performed under the Task Action Plan A-46 was to establish an explicit set of guidelines and acceptance criteria to judge the adequacy of equipment under seismic loading at all operating plants, in lieu of requiring qualification to the current criteria that are applied to new plants. This report summarizes the work accomplished on USI A-46 by the Nuclear Regulatory Commission staff and its contractors, Idaho National Engineering Laboratory, Southwest Research Institute, Brookhaven National Laboratory, and Lawrence Livermore National Laboratory. In addition, the collection and review of seismic experience data by the Seismic Qualification Utility Group and the review and recommendations of a group of seismic consultants, the Senior Seismic Review Advisory Panel, are presented. Staff assessment of work accomplished under USI A-46 leads to the conclusion that the use of seismic experience data provides the most reasonable alternative to current qualification criteria. Consideration of seismic qualification by use of experience data was a specific task in USI A-46. Several other A-46 tasks serve to support the use of an experience data base

  7. Electromagnetic device of the safety screw-nut type

    International Nuclear Information System (INIS)

    Defaucheux, Jean; Guedj, Freddy.

    1981-01-01

    System providing for the vertical displacement of nuclear reactor control rods in a non-magnetic and cylindrical leak tight containment. This device is composed of a stator located around the upper part of the containment and, inside this containment, a rotor also in the upper part of this containment, which is free in axial translation along its shaft which it drives rotationally but which is fixed in translation. This shaft drives a threaded rod working in conjunction with a nut and able to slide vertically without turning inside the containment and supporting the reactor control rods. When the stator is not powered, the threaded rod and nut assembly falls to the bottom of the containment and may be easily raised by powering the stator [fr

  8. Italy: Analysis of Solutions for Passively Actuated Safety Shutdown Devices

    International Nuclear Information System (INIS)

    Burgazzi, L.

    2015-01-01

    This article looks at different special shutdown systems specifically engineered for prevention of severe accidents, to be implemented on Fast Reactors, with main focus on the investigation of the performance of the self-actuated shutdown systems in Sodium Fast Reactors. The passive shut-down systems are designed to shut-down system only by inherent passive reactivity feedback mechanism, under unprotected accident conditions, implying failure of reactor protection system. They are conceived to be self-actuated without any signal elaboration, since the actuation of the system is triggered by the effects induced by the transient like material dilatation, in case of overheating of the coolant for instance, according to Fast Reactor design to meet the safety requirements

  9. Integration of transport and handling equipment at CERN criteria to satisfy operational needs and safety aspects

    CERN Document Server

    Bertone, C; CERN. Geneva. TS Department

    2004-01-01

    Within the last 4 years TS-IC-HM (former ST-HM group) integrated about 150 transport and handling supplies including 29 cranes, 20 fork lift trucks, 60 tunnel vehicles. Most of these are standardised supplies, but very often special functionality has been implemented and the complexity of the equipment has been increased. With the Rocla cryo-dipol transporters even prototype equipment was integrated that had been specially designed for CERN. This paper discusses the differences regarding the actions that have to be performed when the different kind of equipment have to be integrated.

  10. Blast Analysis of Laminated Glass Curtain Walls Equipped by Viscoelastic Dissipative Devices

    Directory of Open Access Journals (Sweden)

    Chiara Bedon

    2012-09-01

    Full Text Available Nonlinear numerical simulations are reported for a conventional unitized laminated glass curtain wall subjected to high- and low-level air blast loading. The studied curtain wall, spanning floor to floor, consisted of a laminated glass panel, a continuous bead of structural silicone sealant, a split screw spline frame and four rigid brackets. Firstly, a linear elastic FE-model (M01 is presented to investigate dynamic stresses and deflections due to explosion, by taking into account geometrical nonlinearities. Since, in similar glazing systems, it is important to take into account the possible cracking of glass lites, a second model (M02, calibrated to previous experimental data, is proposed. In it, glass behaves as a brittle-elastic material, whereas an elastoplastic characteristic curve is assumed for mullions. As a result, the design explosion seriously affects the main components of the curtain wall, especially the bead of silicone. To address these criticalities, additional viscoelastic (VE devices are installed at the frame corners (M03. Their effectiveness explains the additional deformability provided to the conventional curtain wall, as well as the obvious dissipation of the incoming energy due to blast loading. Structural and energy capabilities provided by devices are highlighted by means of numerical simulations.

  11. Health and safety manual

    International Nuclear Information System (INIS)

    1980-02-01

    The manual consists of the following chapters: general policies and administration; the Environmental Health and Safety Department; the Medical Services Department: biological hazards; chemical safety; confined space entry; cryogenic safety; electrical safety; emergency plans; engineering and construction; evacuations, trenching, and shoring; fire safety; gases, flammable and compressed; guarding, mechanical; ladders and scaffolds, work surfaces; laser safety; materials handling and storage; noise; personal protective equipment; pressure safety; radiation safety, ionizing and non-ionizing; sanitation; seismic safety; training, environmental health and safety; tools, power and hand-operated; traffic and transportation; and warning signs and devices

  12. Normal people working in normal organizations with normal equipment: system safety and cognition in a mid-air collision.

    Science.gov (United States)

    de Carvalho, Paulo Victor Rodrigues; Gomes, José Orlando; Huber, Gilbert Jacob; Vidal, Mario Cesar

    2009-05-01

    A fundamental challenge in improving the safety of complex systems is to understand how accidents emerge in normal working situations, with equipment functioning normally in normally structured organizations. We present a field study of the en route mid-air collision between a commercial carrier and an executive jet, in the clear afternoon Amazon sky in which 154 people lost their lives, that illustrates one response to this challenge. Our focus was on how and why the several safety barriers of a well structured air traffic system melted down enabling the occurrence of this tragedy, without any catastrophic component failure, and in a situation where everything was functioning normally. We identify strong consistencies and feedbacks regarding factors of system day-to-day functioning that made monitoring and awareness difficult, and the cognitive strategies that operators have developed to deal with overall system behavior. These findings emphasize the active problem-solving behavior needed in air traffic control work, and highlight how the day-to-day functioning of the system can jeopardize such behavior. An immediate consequence is that safety managers and engineers should review their traditional safety approach and accident models based on equipment failure probability, linear combinations of failures, rules and procedures, and human errors, to deal with complex patterns of coincidence possibilities, unexpected links, resonance among system functions and activities, and system cognition.

  13. Manual on Safety Aspects of the Design and Equipment of Hot Laboratories

    International Nuclear Information System (INIS)

    1969-01-01

    With the development of atomic energy application and research, hot laboratories are now being constructed in a number of countries. The present publication describes and discusses experience in several countries in designing equipment for these laboratories. The safe handling of highly radioactive substances is the main purpose of hot laboratory design and equipment. The manual aims at helping those persons, particularly in the developing countries, who plan to design and construct a new hot laboratory or modify an existing one. It does not deal in great detail with the engineering design of protective and handling equipment; these matters can be found in the comprehensive list of references. The manual itself covers only basic ideas and different approaches in the design of laboratory building, hot cells, shielded and glove boxes, fume cupboards, and handling and viewing equipment. Systems for transferring materials and main services are also discussed.

  14. Stress corrosion cracking of equipment materials in domestic pressurized water reactors and the relevant safety management

    International Nuclear Information System (INIS)

    Sun Haitao

    2015-01-01

    International and domestic research and project state about stress corrosion cracking of nuclear equipments and materials (including austenitic stainless steel and nickel based alloys) in pressurized water reactor are discussed, and suggestions on how to prevent, mitigate ana deal with the stress corrosion cracking issues in domestic reactors are given in this paper based on real case analysis and study ondomestic nuclear equipment and material stress corrosion cracking failure. (author)

  15. Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device

    Directory of Open Access Journals (Sweden)

    Jong-Gu Choi

    2011-01-01

    Full Text Available To measure precise blood pressure (BP and pulse rate without using a cuff, we have developed an arterial pulsimeter consisting of a small, portable apparatus incorporating a Hall device. Regression analysis of the pulse wave measured during testing of the arterial pulsimeter was conducted using two equations of the BP algorithm. The estimated values of BP obtained by the cuffless arterial pulsimeter over 5 s were compared with values obtained using electronic or liquid mercury BP meters. The standard deviation between the estimated values and the measured values for systolic and diastolic BP were 8.3 and 4.9, respectively, which are close to the range of values of the BP International Standard. Detailed analysis of the pulse wave measured by the cuffless radial artery pulsimeter by detecting changes in the magnetic field can be used to develop a new diagnostic algorithm for BP, which can be applied to new medical apparatus such as the radial artery pulsimeter.

  16. Safety catching device for pipes in missile shielding cylinders of nuclear power plants

    International Nuclear Information System (INIS)

    Hering, S.; Doll, B.

    1976-01-01

    The safety catching device consists of a steel wire passed in U-shape around the pipe to be caught and supported by two anchor ties embedded in the concrete of the missile shielding cylinder. This flexible catching device is to cause the energy released in case of a pipe rupture to be absorbed and no dangerous bending shesses to be transferred to the walls of the missile shielding cylinder. (UWI) [de

  17. 77 FR 71752 - Federal Motor Vehicle Safety Standards; Lamps, Reflective Devices, and Associated Equipment

    Science.gov (United States)

    2012-12-04

    ... Optical Character Recognition (OCR) process, thus allowing the agency to search and copy certain portions of your submissions.\\9\\ \\9\\ Optical character recognition (OCR) is the process of converting an image...

  18. 76 FR 48009 - Federal Motor Vehicle Safety Standards; Lamps, Reflective Devices, and Associated Equipment

    Science.gov (United States)

    2011-08-08

    ... (AAM), Ford Motor Company (Ford), Nissan North America (Nissan), Toyota Motor North America (Toyota... ``* * * of multiple compartment lamps or * * *''. Toyota requested that paragraph S14.3.1 be modified to use... photometric requirements of DRLs. Valeo claimed that there is no way to reconcile Table 1 of SAE J222 (DEC...

  19. 77 FR 40843 - Federal Motor Vehicle Safety Standard No. 108; Lamp, Reflective Devices, and Associated Equipment

    Science.gov (United States)

    2012-07-11

    ... limiting the impacts of glare. Our current standard primarily treats a headlamp as a separate piece of...) at any time by going to http://www.regulations.gov . Follow the online instructions for accessing the dockets. You may also read the materials at the Docket Management Facility by going to the street address...

  20. 75 FR 21567 - Federal Motor Vehicle Safety Standard No. 108; Lamp, Reflective Devices and Associated Equipment...

    Science.gov (United States)

    2010-04-26

    ... the motorcycle headlighting system location requirements for a single headlamp with multiple light sources. The current standard requires that the light sources contained in a single motorcycle headlamp containing multiple light sources be located on the vertical centerline of the vehicle or horizontally...

  1. 78 FR 54209 - Federal Motor Vehicle Safety Standards; Lamps, Reflective Devices, and Associated Equipment

    Science.gov (United States)

    2013-09-03

    ... traffic management organizations use license plate recognition (reading) technology to read license plate... plate recognition technology to read license plate characters. NHTSA seeks comment as to whether... negatively affect the ability of license plate recognition technology to read license plate characters. \\6...

  2. Performance Verification for Safety Injection Tank with Fluidic Device

    International Nuclear Information System (INIS)

    Yune, Seok Jeong; Kim, Da Yong

    2014-01-01

    In LBLOCA, the SITs of a conventional nuclear power plant deliver excessive cooling water to the reactor vessel causing the water to flow into the containment atmosphere. In an effort to make it more efficient, Fluidic Device (FD) is installed inside a SIT of Advanced Power Reactor 1400 (APR 1400). FD, a complete passive controller which doesn't require actuating power, controls injection flow rates which are susceptible to a change in the flow resistance inside a vortex chamber of FD. When SIT Emergency Core Cooling (ECC) water level is above the top of the stand pipe, the water enters the vortex chamber through both the top of the stand pipe and the control ports resulting in injection of the water at a large flow rate. When the water level drops below the top of the stand pipe, the water only enters the vortex chamber through the control ports resulting in vortex formation in the vortex chamber and a relatively small flow injection. Performance verification of SIT shall be carried out because SITs play an integral role to mitigate accidents. In this paper, the performance verification method of SIT with FD is presented. In this paper, the equations for calculation of flow resistance coefficient (K) are induced to evaluate on-site performance of APR 1400 SIT with FD. Then, the equations are applied to the performance verification of SIT with FD and good results are obtained

  3. Research Devices Maintenance Programs and Safety Network Infrastructures in Nuclear Malaysia

    International Nuclear Information System (INIS)

    Zainudin Jaafar; Muhammad Zahidee Taat; Ishak Mansor

    2015-01-01

    Instrumentation and Automation Center (PIA) is responsible in carrying out maintenance work for building safety infrastructure and area for nuclear scientific and research work. Care cycle and nuclear scientific tools starting from the preparation of specifications until devices disposal- to get the maximum output from devices therefore PIA has introduced Effective and Comprehensive Maintenance Plan under Management/ Trust/ Development/ Science Fund budgets and also user, Asset Management, caring and handling of the devices. This paper also discussed more on case study related to using and handling so that it can be guidance and standard when its involving mishandling, improper maintenance, inadequacy of supervision and others including improvement suggestion programs. (author)

  4. Regulatory analysis for the resolution of generic issue 57: Effects of Fire Protection System Actuation on Safety-Related Equipment

    International Nuclear Information System (INIS)

    Woods, H.W.

    1993-10-01

    Actuation of Fire Protection Systems (FPS) in Nuclear Power Plants have resulted in adverse interactions with equipment important to safety. Precursor operational experience has shown that 37% of all FPS actuations damaged some equipment, and 20% of all FPS actuations have resulted in a plant transient and reactor trip. On an average 0.17 FPS actuations per reactor year have been experienced in nuclear power plants in this country. This report presents the regulatory analysis for GI-57, ''Effects of Fire Protection System Actuation on Safety-Related Equipment''. The risk reduction estimates, cost/benefit analyses, and other insights gained during this effort have shown that implementation of the recommendations contained in this report can significantly reduce risk, and that these improvements can be warranted in accordance with the backfit rule, 10 CFR 50.109(a)(3). However, plant specific analyses are required in order to identify such improvements. Generic analyses can not serve to identify improvements that could be warranted for individual, specific plants. Plant specific analyses of the type needed for this purpose are underway as part of the Individual Plant Examination of External Events (IPEEE) program

  5. Risk assessment of medical devices: evaluation of microbiological and toxicological safety

    International Nuclear Information System (INIS)

    Dorpema, J.W.

    1995-01-01

    Safety assessment of medical devices includes sterilization and biological evaluation or biocompatability testing. Sterilization by ETO gas is criticised for their carcinogenic potency or even banned. Mutual acceptance of biological evaluation test results is promoted by a laboratory accreditation and qualification program. (Author)

  6. Safety motion increase of trains by improvement diagnostics process devices of railway automation

    Directory of Open Access Journals (Sweden)

    B.M.Bondarenko

    2012-12-01

    Full Text Available The complex use of methods of nondestructive check for the automated diagnostics electromagnetic relays of railway automation the first class reliability is offered. The methods determination of their mechanical parameters are resulted, that allows to exclude a human factor from the control, promote reliability of devices railway automation and safety motion of railway transport.

  7. The Challenges of Balancing Safety and Security in Implantable Medical Devices.

    Science.gov (United States)

    Katzis, Konstantinos; Jones, Richard W; Despotou, George

    2016-01-01

    Modern Implantable Medical Devices (IMDs), implement capabilities that have contributed significantly to patient outcomes, as well as quality of life. The ever increasing connectivity of IMD's does raise security concerns though there are instances where implemented security measures might impact on patient safety. The paper discusses challenges of addressing both of these attributes in parallel.

  8. Safety and effectiveness considerations for clinical studies of visual prosthetic devices

    Science.gov (United States)

    Cohen, Ethan D.

    2007-03-01

    With the advent of new designs of visual prostheses for the blind, FDA is faced with developing guidance for evaluating their engineering, safety and patient performance. Visual prostheses are considered significant risk medical devices, and their use in human clinical trials must be approved by FDA under an investigation device exemption (IDE). This paper contains a series of test topics and design issues that sponsors should consider in order to assess the safety and efficacy of their device. The IDE application includes a series of pre-clinical and clinical data sections. The pre-clinical section documents laboratory, animal and bench top performance tests of visual prostheses safety and reliability to support a human clinical trial. The materials used in constructing the implant should be biocompatible, sterile, corrosion resistant, and able to withstand any forces exerted on it during normal patient use. The clinical data section is composed of items related to patient-related evaluation of device performance. This section documents the implantation procedure, trial design, statistical analysis and how visual performance is assessed. Similar to cochlear implants, a visual prosthesis is expected to last in the body for many years, and good pre-clinical and clinical testing will help ensure its safety, durability and effectiveness.

  9. The Impact Of Occupational Hazards In Workplaces - Maintenance, A Main Target For Ensuring The Safety Of Working Equipment

    Science.gov (United States)

    Antonov, Anca Elena; Buica, Georgeta; Darabont, Doru Costin; Beiu, Constantin

    2015-07-01

    For use of work equipment having the economic performance and the highest level of safety, it must be ensured that it complies with the conditions set by the manufacturer in terms of putting into service, use and maintenance operations, ensuring appropriate technical and environmental requirements, including appropriate measures and means of protection. The research aimed to identify and analyze the occupational hazards associated to maintenance operations, in terms of the history of the adjustments, maintenance, cleaning and repair, including the case that occur after the incidents, capital repairs and upgrades. The results of the research consisted in the development of recommendations on the effective management of maintenance activities of work equipment and a software model to enable an efficient management of maintenance, as a tool for occupational hazards in companies - premise for increasing the competitiveness of employers in the market economy.

  10. Methods for medical device and equipment procurement and prioritization within low- and middle-income countries: findings of a systematic literature review.

    Science.gov (United States)

    Diaconu, Karin; Chen, Yen-Fu; Cummins, Carole; Jimenez Moyao, Gabriela; Manaseki-Holland, Semira; Lilford, Richard

    2017-08-18

    Forty to 70 % of medical devices and equipment in low- and middle-income countries are broken, unused or unfit for purpose; this impairs service delivery to patients and results in lost resources. Undiscerning procurement processes are at the heart of this issue. We conducted a systematic review of the literature to August 2013 with no time or language restrictions to identify what product selection or prioritization methods are recommended or used for medical device and equipment procurement planning within low- and middle-income countries. We explore the factors/evidence-base proposed for consideration within such methods and identify prioritization criteria. We included 217 documents (corresponding to 250 texts) in the narrative synthesis. Of these 111 featured in the meta-summary. We identify experience and needs-based methods used to reach procurement decisions. Equipment costs (including maintenance) and health needs are the dominant issues considered. Extracted data suggest that procurement officials should prioritize devices with low- and middle-income country appropriate technical specifications - i.e. devices and equipment that can be used given available human resources, infrastructure and maintenance capacity. Suboptimal device use is directly linked to incomplete costing and inadequate consideration of maintenance services and user training during procurement planning. Accurate estimation of life-cycle costing and careful consideration of device servicing are of crucial importance.

  11. Emergent risks to workplace safety as a result of IT connections of and between work equipment

    NARCIS (Netherlands)

    Steijn, W.; Vorm, J. van der; Luijf, E.; Gallis, R.; Beek, D. van der

    2016-01-01

    The ever-greater integration of new technologies in work equipment is regarded by some as the fourth industrial revolution1 and referred to as ‘smart industry’2. Examples that come to mind include automation through the use of embedded software, remotely controlling heavy materials, and the

  12. The performance of a prototype device designed to evaluate general quality parameters of X-ray equipment

    International Nuclear Information System (INIS)

    Murata, C.H.; Fernandes, D.C.; Lavínia, N.C.; Caldas, L.V.E; Pires, S.R; Medeiros, R.B.

    2014-01-01

    a multifunctional instrument that can appropriately evaluate the performance of radiological equipment. - Highlights: • An instrument was developed to evaluate the performance of radiological equipment. • The prototype containing solid detector was compared with commercial instruments. • The prototype device shows comparable reproducibility and accuracy with commercial instruments. • The prototype can be used for evaluate kVp, exposure time, and HVL using a single X-ray exposure

  13. 21 CFR 866.4540 - Immunonephelometer equipment.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents § 866.4540 Immunonephelometer equipment. (a) Identification. Immunonephelometer equipment for clinical use...

  14. 21 CFR 866.4520 - Immunofluorometer equipment.

    Science.gov (United States)

    2010-04-01

    ...) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents § 866.4520 Immunofluorometer equipment. (a) Identification. Immunofluorometer equipment for clinical use with...

  15. 78 FR 16358 - Safety Advisory 2013-02; Low-Speed, Wheel-Climb Derailments of Passenger Equipment With “Stiff...

    Science.gov (United States)

    2013-03-14

    ..., Staff Director, Motive Power and Equipment Division, Office of Railroad Safety, FRA, 1200 New Jersey Avenue SE., Washington, DC 20590, telephone (202) 493-6322; or Anna Nassif Winkle, Trial Attorney, Office... studies conducted by the equipment manufacturer and FRA using computer modeling indicate that an uneven...

  16. Height, fun and safety in the design of children's playground equipment.

    Science.gov (United States)

    Wakes, Sarah; Beukes, Amanda

    2012-01-01

    The study reported in this paper adopted a holistic design approach to investigate issues associated with height related playground injuries from a users' perspective. The main objective was to gain an understanding of the relationship between height and fun so as to establish practical guidelines for addressing the causes of height related injuries whilst maintaining the attributes of playground equipment that children find fun and challenging. Results show that, on the one hand, the risk of injury increases when height is coupled with the use of upper body strength and, on the other hand, that coordination is a greater source of fun and challenge than height for children. Accordingly, it is suggested that the level of risk of injury attached to children's playground equipment can be reduced when the use of lower body strength and coordination are combined with lower free fall heights.

  17. 10 CFR 32.101 - Schedule B-prototype tests for luminous safety devices for use in aircraft.

    Science.gov (United States)

    2010-01-01

    ....101 Schedule B—prototype tests for luminous safety devices for use in aircraft. An applicant for a... 10 Energy 1 2010-01-01 2010-01-01 false Schedule B-prototype tests for luminous safety devices for use in aircraft. 32.101 Section 32.101 Energy NUCLEAR REGULATORY COMMISSION SPECIFIC DOMESTIC LICENSES...

  18. Reliability prediction for the vehicles equipped with advanced driver assistance systems (ADAS and passive safety systems (PSS

    Directory of Open Access Journals (Sweden)

    Balbir S. Dhillon

    2012-10-01

    Full Text Available The human error has been reported as a major root cause in road accidents in today’s world. The human as a driver in road vehicles composed of human, mechanical and electrical components is constantly exposed to changing surroundings (e.g., road conditions, environmentwhich deteriorate the driver’s capacities leading to a potential accident. The auto industries and transportation authorities have realized that similar to other complex and safety sensitive transportation systems, the road vehicles need to rely on both advanced technologies (i.e., Advanced Driver Assistance Systems (ADAS and Passive Safety Systems (PSS (e.g.,, seatbelts, airbags in order to mitigate the risk of accidents and casualties. In this study, the advantages and disadvantages of ADAS as active safety systems as well as passive safety systems in road vehicles have been discussed. Also, this study proposes models that analyze the interactions between human as a driver and ADAS Warning and Crash Avoidance Systems and PSS in the design of vehicles. Thereafter, the mathematical models have been developed to make reliability prediction at any given time on the road transportation for vehicles equipped with ADAS and PSS. Finally, the implications of this study in the improvement of vehicle designs and prevention of casualties are discussed.

  19. 30 CFR 57.9330 - Clearance for surface equipment.

    Science.gov (United States)

    2010-07-01

    ... NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Loading, Hauling, and Dumping Safety Devices, Provisions, and Procedures for Roadways, Railroads, and Loading and... the farthest projection of moving railroad equipment shall be provided on at least one side of the...

  20. Semiconductor Manufacturing equipment introduction

    International Nuclear Information System (INIS)

    Im, Jong Sun

    2001-02-01

    This book deals with semiconductor manufacturing equipment. It is comprised of nine chapters, which are manufacturing process of semiconductor device, history of semiconductor manufacturing equipment, kinds and role of semiconductor manufacturing equipment, construction and method of semiconductor manufacturing equipment, introduction of various semiconductor manufacturing equipment, spots of semiconductor manufacturing, technical elements of semiconductor manufacturing equipment, road map of technology of semiconductor manufacturing equipment and semiconductor manufacturing equipment in the 21st century.

  1. Systems analysis of radiation safety during dismantling of power-plant equipment at a nuclear power station

    International Nuclear Information System (INIS)

    Bylkin, B.K.; Shpitser, V.Ya.

    1993-01-01

    A systems analysis of the radiation safety makes possible an ad hoc determination of the elements forming the system, as well as the establishment of the characteristics of their interaction with radiation-effect factors. Here the authors will present part of the hierarchical analysis procedure, consisting in general of four separate procedures. The purpose is to investigate and analyze the mean and stable (on the average) indices of radiation safety, within the framework of alternative mathematical models of dismantling the power-plant equipment of a nuclear power station. The following three of the four procedures are discussed: (1) simulated projection, of the processing of radioactive waste; (2) analysis of the redistribution of radionuclides during the industrial cycle of waste treatment; (3) planning the collective dose load during the dismantling operation. Within the framework of the first of these procedures, the solutions to the problem of simulating a waste-treatment operation of maximum efficiency are analyzed. This analysis is based on the use of a data base for the parameters of the installations, assemblies, and equipment, enabling the integration of these in a simulation of a complex automated facility. The results were visualized in an AUTOCAD-10 medium using a graphical data base containing an explanation of the rooms

  2. Terms standardization between the rules of diagnosis radiation equipment safety management and atomic energy law: problems and suggestions

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hwa Gon; Kang, Se Sik; Kim, Chang Soo; Park, Cheol Seo [Catholic University of Pusan, Busan (Korea, Republic of)

    2006-03-15

    The rules and terms are described different meaning in this results the research is accomplished for preventing practical workers from confusion. Atomic law are kept up modification and development in our situation by the ICRP's recommendation, on the other hand, the rules of diagnosis radiation equipment safety managements are modified partial, then resulted in confusion. The study was comparison between the rules of diagnosis radiation equipment safety management and atomic energy law, and the modification items obtained were as follows. With each other different the terms and units are used. With the exception of special terms for affairs usage, it is needless to say that common term uniformity is standardized. The standardization of rules and guidance have not need to confusion radiological practical workers. The following is omitted. The radiation protection against the patient and the hospital visitor. Radiation dose limit of the woman patient who is in the process of becoming pregnant. Radiation dose limit of the person who is not regarded as medical exposure. The control of the exposure of pregnant of women at work.

  3. Terms standardization between the rules of diagnosis radiation equipment safety management and atomic energy law: problems and suggestions

    International Nuclear Information System (INIS)

    Kim, Hwa Gon; Kang, Se Sik; Kim, Chang Soo; Park, Cheol Seo

    2006-01-01

    The rules and terms are described different meaning in this results the research is accomplished for preventing practical workers from confusion. Atomic law are kept up modification and development in our situation by the ICRP's recommendation, on the other hand, the rules of diagnosis radiation equipment safety managements are modified partial, then resulted in confusion. The study was comparison between the rules of diagnosis radiation equipment safety management and atomic energy law, and the modification items obtained were as follows. With each other different the terms and units are used. With the exception of special terms for affairs usage, it is needless to say that common term uniformity is standardized. The standardization of rules and guidance have not need to confusion radiological practical workers. The following is omitted. The radiation protection against the patient and the hospital visitor. Radiation dose limit of the woman patient who is in the process of becoming pregnant. Radiation dose limit of the person who is not regarded as medical exposure. The control of the exposure of pregnant of women at work

  4. Independent assembly technology for DCS safety equipment in nuclear power plant

    International Nuclear Information System (INIS)

    Hao Aixia

    2014-01-01

    A independent assembly technology of identification and verification was proposed, which included special process, wiring process and verification process. The safety reliability and practicability of the proposed technology were verified according to the application in FirmSys assembly implemented by China Techenergy Co., Ltd. (author)

  5. Evaluation of microwave detection equipment in terms of reliability, durability and pedestrian safety.

    NARCIS (Netherlands)

    Schagen, I. van & Sherborne, D.

    1991-01-01

    Urban traffic light cycle times are almost exclusively directed at maximizing throughput and minimizing delay of motorized traffic. The needs of pedestrians and pedal cyclists are of minor importance and their delay times are usually disregarded. Both safety and mobility of pedestrians and pedal

  6. Methodology of assessment of the impact on the risk of changes in peak times of unavailability of safety equipment integrating treatment and analysis of uncertainties

    International Nuclear Information System (INIS)

    Martorell, S.; Villamizar, M.; Marton, I.; Villanueva, J. f.; Carlos, S.; Sanchez, A. I.

    2013-01-01

    Surveillance of safety equipment requirements form parts of the technical specifications of Performance included in the bases of operation of nuclear power plants license, so they are center of attention in the study of improvements to the safety of the operation of the plant using different methods, both traditional deterministic as probabilistic.

  7. Passive safety device and internal short tested method for energy storage cells and systems

    Science.gov (United States)

    Keyser, Matthew; Darcy, Eric; Long, Dirk; Pesaran, Ahmad

    2015-09-22

    A passive safety device for an energy storage cell for positioning between two electrically conductive layers of the energy storage cell. The safety device also comprising a separator and a non-conductive layer. A first electrically conductive material is provided on the non-conductive layer. A first opening is formed through the separator between the first electrically conductive material and one of the electrically conductive layers of the energy storage device. A second electrically conductive material is provided adjacent the first electrically conductive material on the non-conductive layer, wherein a space is formed on the non-conductive layer between the first and second electrically conductive materials. A second opening is formed through the non-conductive layer between the second electrically conductive material and another of the electrically conductive layers of the energy storage device. The first and second electrically conductive materials combine and exit at least partially through the first and second openings to connect the two electrically conductive layers of the energy storage device at a predetermined temperature.

  8. Framework conditions and requirements to ensure the technical functional safety of reprocessed medical devices.

    Science.gov (United States)

    Kraft, Marc

    2008-09-03

    Testing and restoring technical-functional safety is an essential part of medical device reprocessing. Technical functional tests have to be carried out on the medical device in the course of the validation of reprocessing procedures. These ensure (in addition to the hygiene tests) that the reprocessing procedure is suitable for the medical device. Functional tests are, however, also a part of reprocessing procedures. As a stage in the reprocessing, they ensure for the individual medical device that no damage or other changes limit the performance. When determining which technical-functional tests are to be carried out, the current technological standard has to be taken into account in the form of product-specific and process-oriented norms. Product-specific norms primarily define safety-relevant requirements. The risk management method described in DIN EN ISO 14971 is the basis for recognising hazards; the likelihood of such hazards arising can be minimised through additional technical-functional tests, which may not yet have been standardised. Risk management is part of a quality management system, which must be bindingly certified for manufacturers and processors of critical medical devices with particularly high processing demands by a body accredited by the competent authority.

  9. Safety evaluation of stamp type digital microneedle devices in hairless mice.

    Science.gov (United States)

    Park, Kui Young; Jang, Woo Sun; Lim, Yun Young; Ahn, Joo Hee; Lee, Sang Jin; Kim, Chan Woong; Kim, Sung Eun; Kim, Beom Joon; Kim, Myeung Nam

    2013-02-01

    Microneedles provide a minimally invasive means to transport molecules into the skin. A number of specific strategies have been employed to use microneedles for transdermal delivery. The purpose of this study was to investigate the safety of two new digital microneedle devices (Digital Hand® and Digital Pro®; Bomtech Electronics Co., Ltd., Seoul, Korea) for the perforation of skin in skin-hairless-1 mice. This device replaces conventional needles and is designed specifically for intradermal delivery. We used two newly developed digital microneedle devices to perforate the skin of skin-hairless-1 mice. We conducted a comparative study of the two digital microneedle devices and DTS® (Disk type-microneedle Therapy System; DTS lab., Seoul, Korea). To evaluate skin stability, we performed visual and dermatoscopic inspections, measurements of transepidermal water loss, and biopsies. The two novel digital microneedle devices did not induce significant abnormalities of the skin on visual or dermatoscopic inspection, regardless of needle size (0.25~2.0 mm). No significant histopathological changes, such as inflammatory cell infiltration, desquamation of the stratum corneum, or disruption of the basal layer, were observed. The digital microneedle devices and microneedle therapy system produced similar results on measures of skin stability. These two novel digital microneedle devices are safe transdermal drug delivery systems.

  10. Absolute air filtering equipment in the nuclear industrie. Design - Safety - Experience

    International Nuclear Information System (INIS)

    Lucas, J.C.

    1977-01-01

    The problems encountered in the design of absolute filters (HEPA FILTERS) are presented: glass-fibre filter papers; standards and characteristics: efficiency, fire-resistance, humidity-resistance, radiation-resistance, etc; various types of paper folding: deep folds and small folds, dihedrally mounted; filtering elements; designs; characteristics and quality control; The design of filtration equipment is also analysed: mounting in metal or concrete casings. French and American designs (Regulatory Guide 1-52); and gas-tight casings allowing contaminated filters to be renewed without breaking the gas-tight seal

  11. An overview of review guidelines for HDL programmable devices in nuclear safety systems

    International Nuclear Information System (INIS)

    Komanduri, Raghavan; Srivani, L.; Thirugnana Murthy, D.

    2013-01-01

    HDL programmable devices viz. CPLDs and FPGAs are increasingly being used to implement digital designs in the I and C systems performing safety functions of nuclear power plants. Synthesizable RTL descriptions manually written in HDLs are the first step in developing industry standard large scale digital designs. The reliability of the implementation is determined by the methodologies followed by the designer during development. Very few guidelines on HPD design practices, specific to nuclear industry are available. This paper presents an overview of the existing guidelines such as IEC 62566 and U.S. NRC's 'Review guidelines for FPGAs in nuclear power plant safety systems'. (author)

  12. An experimental study of the flow characteristics of fluidic device in a passive safety injection tank

    International Nuclear Information System (INIS)

    Cho, Seok; Song, Chul Hwa; Won, Suon Yeon; Min, Kyong Ho; Chung, Moon Ki

    1998-01-01

    It is considered to adopt passive safety injection tank (SIT) as a enhanced safety feature in KNGR. Passive SIT employs a vortex chamber as a fluidic device, which control injection flow rate passively by the variation of flow resistance produced by vortex intensity within the vortex chamber. To investigate the flow characteristics of the vortex chamber many tests have been carried out by using small-scale test facility. In this report the effects of geometric parameters of vortex chamber on discharge flow characteristics and the velocity measurement result of flow field, measured by PIV, are presented and discussed. (author). 25 refs., 11 tabs., 31 figs

  13. Self-centering and damping capabilities of a tension-compression device equipped with superelastic NiTi wires

    International Nuclear Information System (INIS)

    Soul, H; Yawny, A

    2015-01-01

    The hysteretic damping capacity and high recoverable strains characterizing the superelastic response of shape memory alloys (SMA) make these materials attractive for protection systems of structures subjected to dynamic loads. A successful implementation however is conditioned by functional fatigue exhibited by the SMA when subjected to cyclic loading. The residual deformation upon cycling and the efficiency in material usage are the two most restrictive issues in this sense. In this paper, a device equipped with superelastic NiTi SMA wires and capable of supporting external tension compression loads with optimized properties is presented. It is shown how the introduction of the wires’ pre-straining allows for the absorption of deleterious residual deformation without affecting the self-centering capabilities upon unloading, in contrast with what occurs for pre-strained tendons. These features were experimentally verified in an in-scale prototype composed of two 1.2 mm diameter superelastic NiTi SMA wires. In order to numerically assess the dynamic response of a simple structure subjected to seismic excitations, a multilinear superelasticity model for the NiTi wires was developed. (paper)

  14. Safety, efficacy, and performance of implanted recycled cardiac rhythm management (CRM) devices in underprivileged patients.

    Science.gov (United States)

    Hasan, Reema; Ghanbari, Hamid; Feldman, Dustin; Menesses, Daniel; Rivas, Daniel; Zakhem, Nicole C; Duarte, Carlos; Machado, Christian

    2011-06-01

    Patients in underdeveloped nations have limited access to life-saving medical technology including cardiac rhythm management (CRM) devices. We evaluated alternative means to provide such technology to this patient population while assessing the safety and efficacy of such a practice. Patients in the United States with clinical indications for extraction of CRM devices were consented. Antemortem CRM devices were cleaned and sterilized following a protocol established at our institution. Surveillance in vitro cultures were performed for quality assurance. The functional status of pulse generators was tested with a pacing system analyzer to confirm at least 70% battery life. Most generators were transported, in person, to an implanting institution in Nicaragua. Recipients with a Class I indication for CRM implantation, and meeting economical criteria set forth, were consented for implantation of a recycled device. Between 2003 and 2009, implantation was performed in 17 patients with an average age of 42.1 ± 20.3 years. Of the 17 patients, nine were male and eight were female. Mean follow-up was 68 ± 38 months. Device evaluation occurred prior to discharge, 4 weeks post implantation, and every 6 months thereafter. There were three deaths during the follow-up period secondary to myocardial infarction, stroke, and heart failure. Hematoma formation occurred in one patient. No infections, early battery depletion, or device malfunction were identified during follow-up. Our case series is the longest follow-up of recipients of recycled antemortem CRM devices. Our findings support the feasibility and safety of this alternative acquisition of life-saving technology. ©2011, The Authors. Journal compilation ©2011 Wiley Periodicals, Inc.

  15. Leaving patients to their own devices? Smart technology, safety and therapeutic relationships.

    Science.gov (United States)

    Ho, Anita; Quick, Oliver

    2018-03-06

    This debate article explores how smart technologies may create a double-edged sword for patient safety and effective therapeutic relationships. Increasing utilization of health monitoring devices by patients will likely become an important aspect of self-care and preventive medicine. It may also help to enhance accurate symptom reports, diagnoses, and prompt referral to specialist care where appropriate. However, the development, marketing, and use of such technology raise significant ethical implications for therapeutic relationships and patient safety. Drawing on lessons learned from other direct-to-consumer health products such as genetic testing, this article explores how smart technology can also pose regulatory challenges and encourage overutilization of healthcare services. In order for smart technology to promote safer care and effective therapeutic encounters, the technology and its utilization must be safe. This article argues for unified regulatory guidelines and better education for both healthcare providers and patients regarding the benefits and risks of these devices.

  16. IEEE Std 600: IEEE trial-use standard requirements for organizations that conduct qualification testing of safety systems equipment for use in nuclear power generating stations

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    The purpose of this standard is to provide requirements for establishing a program for conducting qualification tests of safety systems equipment used in nuclear power generating stations. Compliance with the requirements of this standard does not assure the adequacy of the qualification tests performed. This standard applies to organizations that conduct qualification tests on equipment that has a definable safety function and is an identifiable part of a safety system for use in nuclear power generating stations. It requires a technical program, a quality assurance program, and a demonstrated ability to meet specified technical requirements. It does not apply to materials tests, production tests, normal performance testing, qualification by analysis, qualification by operating experience, or reliability tests such as diesel-generator multiple start tests. The intent of this standard is to achieve greater consistency, reliability, and reproducibility of test results and to provide adequate control of qualification testing of safety systems equipment

  17. Certification of boiler safety equipment with ALSPA P320 system, to IEC 61508 standard; Certification des equipements de securite chaudiere avec le systeme ALSPA P320 selon la norme IEC 61508

    Energy Technology Data Exchange (ETDEWEB)

    Dalzon, J.P. [Alstom Power (France)

    2002-02-01

    Safety and environmental protection are major priorities governing Alstom work on control systems (Alspa P320) for power plant applications, especially when potentially dangerous processes like high-power flame boilers (typically rated at 100 to 600 MW) are involved. Here, automatic protection chains are implemented to guard against the risk of serious incident such as explosion and equipment destruction. In this kind of situation, the IEC 61508 standard provides baseline specifications for certification of safety systems. (authors)

  18. Design and fabrication of equipment and devices for a Radiotherapy department; Diseno y fabricacion de equipos y aditamentos para un departamento de Radioterapia

    Energy Technology Data Exchange (ETDEWEB)

    Picon, C.L.; Zaharia B, M. [Departamento de Radioterapia. Instituto de Enfermedades Neoplasicas, Av. Angamos Este 2520, Lima (Peru)

    1998-12-31

    The objective of this work is to present the possibility to design and construct utilizing local technology, a series of equipment and devices necessaries for a routine in a Radiotherapy Department with typical budget in the Latin-American hospitals. (Author)

  19. The design study of the JT-60SU device. No.8. Nuclear shielding and safety design

    Energy Technology Data Exchange (ETDEWEB)

    Miya, Naoyuki; Kikuchi, Mitsuru; Ushigusa, Kenkichi [Japan Atomic Energy Research Inst., Naka, Ibaraki (Japan). Naka Fusion Research Establishment] [and others

    1998-03-01

    Results of nuclear shielding design study and safety analysis for the steady-state tokamak device JT-60SU are described. D-T operation (option) for two years is adopted in addition to ten years operation using deuterium. Design work has been done in accordance with general laws for radioisotopes handling in Japan as a guideline of safety evaluation, which is applied to the operation of present JT-60U device. Optimization of the shielding design for the device structure including vacuum vessel has been presented to meet with allowable limits of biological shielding determined in advance. It is shown that JT-60SU can be operated safely in the present JT-60 experimental building. It is planed to use 100g/year of tritium in D-T operation phase. A concept of multiple -barrier system is applied to the facility design to prevent propagation of tritium, in which the torus hall and the tritium removal room provide the tertiary confinement. From the design of atmosphere detritiation system for accidental tritium release, it is shown that tritium concentration level can be reduced to the allowable level after two weeks with reasonable compact size components. Safety assessment related to activation of coolant/air, and atmospheric tritium effluents are discussed. (author)

  20. The safety of non-incineration waste disposal devices in four hospitals of Tehran.

    Science.gov (United States)

    Farshad, Aliasghar; Gholami, Hamid; Farzadkia, Mahdi; Mirkazemi, Roksana; Kermani, Majid

    2014-01-01

    The safe management of hospital waste is a challenge in many developing countries. The aim of this study was to compare volatile organic compounds (VOCs) emissions and the microbial disinfectant safety in non-incineration waste disposal devices. VOC emissions and microbial infections were measured in four non-incineration waste disposal devices including: autoclave with and without a shredder, dry heat system, and hydroclave. Using NIOSH and US EPA-TO14 guidelines, the concentration and potential risk of VOCs in emitted gases from four devices were assessed. ProSpore2 biological indicators were used to assess the microbial analysis of waste residue. There was a significant difference in the type and concentration of VOCs and microbial infection of residues in the four devices. Emissions from the autoclave with a shredder had the highest concentration of benzene, ethyl benzene, xylene, and BTEX, and emissions from the hydroclave had the highest concentration of toluene. The highest level of microbial infection was observed in the residues of the autoclave without a shredder. There is an increased need for proper regulation and control of non-incinerator devices and for monitoring and proper handling of these devices in developing countries.

  1. The safety of non-incineration waste disposal devices in four hospitals of Tehran

    Science.gov (United States)

    Farshad, Aliasghar; Gholami, Hamid; Farzadkia, Mahdi; Mirkazemi, Roksana; Kermani, Majid

    2014-01-01

    Background: The safe management of hospital waste is a challenge in many developing countries. Objectives: The aim of this study was to compare volatile organic compounds (VOCs) emissions and the microbial disinfectant safety in non-incineration waste disposal devices. Methods: VOC emissions and microbial infections were measured in four non-incineration waste disposal devices including: autoclave with and without a shredder, dry heat system, and hydroclave. Using NIOSH and US EPA-TO14 guidelines, the concentration and potential risk of VOCs in emitted gases from four devices were assessed. ProSpore2 biological indicators were used to assess the microbial analysis of waste residue. Results: There was a significant difference in the type and concentration of VOCs and microbial infection of residues in the four devices. Emissions from the autoclave with a shredder had the highest concentration of benzene, ethyl benzene, xylene, and BTEX, and emissions from the hydroclave had the highest concentration of toluene. The highest level of microbial infection was observed in the residues of the autoclave without a shredder. Conclusions: There is an increased need for proper regulation and control of non-incinerator devices and for monitoring and proper handling of these devices in developing countries. PMID:25000113

  2. Thermal-Responsive Polymers for Enhancing Safety of Electrochemical Storage Devices.

    Science.gov (United States)

    Yang, Hui; Leow, Wan Ru; Chen, Xiaodong

    2018-03-01

    Thermal runway constitutes the most pressing safety issue in lithium-ion batteries and supercapacitors of large-scale and high-power density due to risks of fire or explosion. However, traditional strategies for averting thermal runaway do not enable the charging-discharging rate to change according to temperature or the original performance to resume when the device is cooled to room temperature. To efficiently control thermal runaway, thermal-responsive polymers provide a feasible and reversible strategy due to their ability to sense and subsequently act according to a predetermined sequence when triggered by heat. Herein, recent research progress on the use of thermal-responsive polymers to enhance the thermal safety of electrochemical storage devices is reviewed. First, a brief discussion is provided on the methods of preventing thermal runaway in electrochemical storage devices. Subsequently, a short review is provided on the different types of thermal-responsive polymers that can efficiently avoid thermal runaway, such as phase change polymers, polymers with sol-gel transitions, and polymers with positive temperature coefficients. The results represent the important development of thermal-responsive polymers toward the prevention of thermal runaway in next-generation smart electrochemical storage devices. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Device for removing hydrogen gas from the safety containment vessel of a nuclear reactor

    International Nuclear Information System (INIS)

    Stiefel, M.

    1983-01-01

    The safe processing of all concentrations of gas mixtures should be possible with such a device using a thermal recombiner of compact construction. A recombiner consisting of a metal case and diverter sheets situated in it is heated by induction. The incoming pipe for the gas mixture enriched with hydrogen and the outgoing pipe for the gas mixture with low hydrogen content are connected together by a three way valve. The third connection to the safety valve takes the larger port of the gas mixture with low hydrogen content back to the safety containment vessel. Sufficient amount of the gas mixture with low hydrogen content is taken via the three way valve to the safety containment vessel to ensure that the hydrogen content of the gas mixture taken to the recombiner remains below the 4% by volume limit. (orig./PW)

  4. Prevention of Medical Device-Related Pressure Injuries Associated With Respiratory Equipment Use in a Critical Care Unit: A Quality Improvement Project.

    Science.gov (United States)

    Padula, Cynthia A; Paradis, Heidi; Goodwin, Robert; Lynch, Judith; Hegerich-Bartula, Deborah

    Medical devices have been identified as an extrinsic risk factor for development of pressure injuries, with as many as 30% to 70% of medical device-related pressure injuries resulting from respiratory equipment. This article describes a quality improvement project undertaken to reduce the occurrence of respiratory device-related pressure injuries in a critically care unit. Multiple actions were implemented to achieve this goal. Respiratory therapists were trained to document occurrences on a daily basis, and apparent cause analyses were conducted on each occurrence. An interdisciplinary team conducted biweekly rounds on patients with respiratory devices and consulted other professionals as indicated. Nurses and respiratory therapists attended an evidence-based, collaborative, educational offering and completed a measure of team functioning before the program and at the end of the study period. The occurrence rates of respiratory device-related pressure injuries were reduced over the project period, and these changes were sustained over the subsequent 12 months.

  5. Contributions to the research programs in nuclear and industrial electronics, domestic production of instrumentation, safety and control systems and equipment for nuclear reactors and auxiliary installations

    International Nuclear Information System (INIS)

    Talpariu, C; Talpariu, J.; Matei, C.

    2001-01-01

    Domestic production of component system and equipment for the control and safety of nuclear facilities was one of the priority objective of the Nuclear Research Institute Pitesti. The problems addressed were particularly related to design and production of analog and digital equipment for measurements, triggering and display of the values of process parameters as well as to regulating complex functions of this equipment. Associated to this effort were the research works concerning: - reliability and in-service life-time of the electronic components and equipment in the safety and control systems for nuclear processes; - radiation endurance of industrial electronic components; utilization of whirling currents in calandria tube testing; - expert systems and applications in nuclear reactor control and safety; design and testing methods of process real time software packages for safety in control critical systems for nuclear domain. There are presented characteristics of the following equipment: 1. amplifier for ionization chambers with triggering comparator circuits for the CANDU 600 reactor shut down system; 2. amplifier for ionization chambers without triggering comparator circuits for power regulating system; 3. safety and regulating computerized system for C9 and C5 cans; 4. acquisition system for dosimetric data in nuclear facilities; 5. program able digital comparator for the reactor shut down system; 6. stationary gamma areal monitors for CANDU 600 reactors and other nuclear facilities

  6. Safety assessment on the key equipment of coal gasification based on SDG-HAZOP method

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, B.; Xu, X.; Ma, X.; Wu, C. [Beijing University of Chemical Technology, Beijing (China)

    2008-07-15

    An example of the coal gasification process was introduced after the explanation of the graphical representation method known as the sign directed graph (SDG). The systematic modeling procedure was also introduced. Firstly, the key variables of the whole system were selected. Then the relationship equations were listed. Finally, the SDG-HAZOP (hazard and operability) model was derived after attaching the abnormal causes and adverse consequences. In order to get a credible SDG model, the model was checked by technicians in the factory. Based on computer-aided analysis, this model can express almost all the dangerous features of the gasification process. It can also reveal the mechanisms of danger propagation, which may effectively help safety engineers to identify potential hazards. 15 refs., 4 figs., 1 tab.

  7. Managing NIF safety equipment in a high neutron and gamma radiation environment.

    Science.gov (United States)

    Datte, Philip; Eckart, Mark; Jackson, Mark; Khater, Hesham; Manuel, Stacie; Newton, Mark

    2013-06-01

    The National Ignition Facility (NIF) is a 192 laser beam facility that supports the Inertial Confinement Fusion program. During the ignition experimental campaign, the NIF is expected to perform shots with varying fusion yield producing 14 MeV neutrons up to 20 MJ or 7.1 × 10(18) neutrons per shot and a maximum annual yield of 1,200 MJ. Several infrastructure support systems will be exposed to varying high yield shots over the facility's 30-y life span. In response to this potential exposure, analysis and testing of several facility safety systems have been conducted. A detailed MCNP (Monte Carlo N-Particle Transport Code) model has been developed for the NIF facility, and it includes most of the major structures inside the Target Bay. The model has been used in the simulation of expected neutron and gamma fluences throughout the Target Bay. Radiation susceptible components were identified and tested to fluences greater than 10(13) (n cm(-2)) for 14 MeV neutrons and γ-ray equivalent. The testing includes component irradiation using a 60Co gamma source and accelerator-based irradiation using 4- and 14- MeV neutron sources. The subsystem implementation in the facility is based on the fluence estimates after shielding and survivability guidelines derived from the dose maps and component tests results. This paper reports on the evaluation and implementation of mitigations for several infrastructure safety support systems, including video, oxygen monitoring, pressure monitors, water sensing systems, and access control interfaces found at the NIF.

  8. Economic benefits of safety-engineered sharp devices in Belgium - a budget impact model.

    Science.gov (United States)

    Hanmore, Emma; Maclaine, Grant; Garin, Fiona; Alonso, Alexander; Leroy, Nicolas; Ruff, Lewis

    2013-11-25

    Measures to protect healthcare workers where there is risk of injury or infection from medical sharps became mandatory in the European Union (EU) from May 2013. Our research objective was to estimate the net budget impact of introducing safety-engineered devices (SEDs) for prevention of needlestick injuries (NSIs) in a Belgian hospital. A 5-year incidence-based budget impact model was developed from the hospital inpatient perspective, comparing costs and outcomes with SEDs and prior-used conventional (non-safety) devices. The model accounts for device acquisition costs and costs of NSI management in 4 areas of application where SEDs are currently used: blood collection, infusion, injection and diabetes insulin administration. Model input data were sourced from the Institut National d'Assurance Maladie-Invalidité, published studies, clinical guidelines and market research. Costs are discounted at 3%. For a 420-bed hospital, 100% substitution of conventional devices by SEDs is estimated to decrease the cumulative 5-year incidence of NSIs from 310 to 75, and those associated with exposure to blood-borne viral diseases from 60 to 15. Cost savings from managing fewer NSIs more than offset increased device acquisition costs, yielding estimated 5-year overall savings of €51,710. The direction of these results is robust to a range of sensitivity and model scenario analyses. The model was most sensitive to variation in the acquisition costs of SEDs, rates of NSI associated with conventional devices, and the acquisition costs of conventional devices. NSIs are a significant potential risk with the use of sharp devices. The incidence of NSIs and the costs associated with their management can be reduced through the adoption of safer work practices, including investment in SEDs. For a Belgian hospital, the budget impact model reports that the incremental acquisition costs of SEDs are offset by the savings from fewer NSIs. The availability of more robust data for NSI reduction

  9. Home Healthcare Medical Devices: A Checklist

    Science.gov (United States)

    ... not using it. Contact your doctor and home healthcare team often to review your health condition. * Check ... assurance of their safety and effectiveness. A home healthcare medical device is any product or equipment used ...

  10. The efficacy and safety of a novel posterior scleral reinforcement device in rabbits

    Energy Technology Data Exchange (ETDEWEB)

    Yuan, Yongguang; Zong, Yao; Zheng, Qishan [State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou (China); Qian, Garrett [University of New South Wales (Australia); Qian, Xiaobin; Li, Yujie; Shao, Wanwen [State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou (China); Gao, Qianying, E-mail: gaoqy@mail.sysu.edu.cn [State Key Laboratory of Ophthalmology, Zhongshan Ophthalmic Center, Sun Yat-sen University, Guangzhou (China)

    2016-05-01

    Purpose: To evaluate the efficacy and safety of posterior scleral reinforcement (PSR) device for myopia suppression in rabbits' eyes. Methods: PSR surgery was performed on the normal 12 8-week-old New Zealand white rabbits' right eyes. To determine efficacy of the device, ophthalmic examination would be taken at pre-operation and post-operation (1 week, 1 month, 3 months, 6 months, and 1 year), such as A-ultrasound, diopter and B-ultrasound. Evaluation of safety were based on the following indicators: intraocular pressure (IOP), slit lamp, fundus photography, fundus fluorescein angiography and pathological examination after surgery. The efficacy and safety of PSR device were evaluated by comparison (treated eyes and contralateral eyes) of pre and post-operation. Results: The novel PSR device could significantly shorten axial length (preoperative axial length: 16.36 ± 0.14 mm, postoperative 1 week, 1 month, 3 months, 6 months and 1 year axial lengths: 15.03 ± 0.28 mm, 15.23 ± 0.32 mm, 15.39 ± 0.31 mm, 15.45 ± 0.22 mm and 15.45 ± 0.22 mm; P = 0.00037 < 0.001) in the treated eyes (right eyes) after surgery. At different postoperative time points, the B-ultrasound images showed that the PSR located in appropriate position and supported the posterior sclera very well. At the same time, IOP of treated eyes kept a relatively stable level (preoperative IOP: 12.56 ± 2.01 mmHg, postoperative IOP: ranging from 11.33 ± 1.23 mmHg to 13.44 ± 2.19 mmHg, P > 0.05) post-operation 1 year. During observation period, there was no significant inflammatory reaction and complications such as anterior chamber flare, empyema, endophthalmitis, vitreous hemorrhage, retina detachment and retinal choroid neovascularization by slit lamp, fundus photography and fundus fluorescein angiography. In addition, there were no pathologic changes be found by comparison treated eyes group and contralateral group eyes based on pathological examinations. Conclusions: In vivo study

  11. Selection of equipment for equipment qualification

    International Nuclear Information System (INIS)

    Torr, K.G.

    1989-01-01

    This report describes the methodology applied in selecting equipment in the special safety systems for equipment qualification in the CANDU 600 MW nuclear generating stations at Gentilly 2 and Point Lepreau. Included is an explanation of the selection procedure adopted and the rationale behind the criteria used in identifying the equipment. The equipment items on the list have been grouped into three priority categories as a planning aid to AECB staff for a review of the qualification status of the special safety systems

  12. Two NextGen Air Safety Tools: An ADS-B Equipped UAV and a Wake Turbulence Estimator

    Science.gov (United States)

    Handley, Ward A.

    Two air safety tools are developed in the context of the FAA's NextGen program. The first tool addresses the alarming increase in the frequency of near-collisions between manned and unmanned aircraft by equipping a common hobby class UAV with an ADS-B transponder that broadcasts its position, speed, heading and unique identification number to all local air traffic. The second tool estimates and outputs the location of dangerous wake vortex corridors in real time based on the ADS-B data collected and processed using a custom software package developed for this project. The TRansponder based Position Information System (TRAPIS) consists of data packet decoders, an aircraft database, Graphical User Interface (GUI) and the wake vortex extension application. Output from TRAPIS can be visualized in Google Earth and alleviates the problem of pilots being left to imagine where invisible wake vortex corridors are based solely on intuition or verbal warnings from ATC. The result of these two tools is the increased situational awareness, and hence safety, of human pilots in the National Airspace System (NAS).

  13. Cocoa Farmers' Compliance with Safety Precautions in Spraying Agrochemicals and Use of Personal Protective Equipment (PPE) in Cameroon.

    Science.gov (United States)

    Oyekale, Abayomi Samuel

    2018-02-13

    The inability of farmers to comply with essential precautions in the course of spraying agrochemicals remains a policy dilemma, especially in developing countries. The objectives of this paper were to assess compliance of cocoa farmers with agrochemical safety measures, analyse the factors explaining involvement of cocoa farmers in the practice of reusing agrochemical containers and wearing of personal protective equipment (PPE). Data were collected with structured questionnaires from 667 cocoa farmers from the Centre and South West regions in Cameroon. Data analyses were carried out with Probit regression and Negative Binomial regression models. The results showed that average cocoa farm sizes were 3.55 ha and 2.82 ha in South West and Centre regions, respectively, and 89.80% and 42.64% complied with manufacturers' instructions in the use of insecticides. Eating or drinking while spraying insecticides and fungicides was reported by 4.20% and 5.10% of all farmers in the two regions, respectively. However, 37.78% and 57.57% of all farmers wore hand gloves and safety boots while spraying insecticides in the South West and Centre regions of Cameroon, respectively. In addition, 7.80% of all the farmers would wash agrochemical containers and use them at home, while 42.43% would wash and use them on their farms. Probit regression results showed that probability of reusing agrochemical containers was significantly influenced ( p agrochemicals.

  14. Cocoa Farmers’ Compliance with Safety Precautions in Spraying Agrochemicals and Use of Personal Protective Equipment (PPE) in Cameroon

    Science.gov (United States)

    2018-01-01

    The inability of farmers to comply with essential precautions in the course of spraying agrochemicals remains a policy dilemma, especially in developing countries. The objectives of this paper were to assess compliance of cocoa farmers with agrochemical safety measures, analyse the factors explaining involvement of cocoa farmers in the practice of reusing agrochemical containers and wearing of personal protective equipment (PPE). Data were collected with structured questionnaires from 667 cocoa farmers from the Centre and South West regions in Cameroon. Data analyses were carried out with Probit regression and Negative Binomial regression models. The results showed that average cocoa farm sizes were 3.55 ha and 2.82 ha in South West and Centre regions, respectively, and 89.80% and 42.64% complied with manufacturers’ instructions in the use of insecticides. Eating or drinking while spraying insecticides and fungicides was reported by 4.20% and 5.10% of all farmers in the two regions, respectively. However, 37.78% and 57.57% of all farmers wore hand gloves and safety boots while spraying insecticides in the South West and Centre regions of Cameroon, respectively. In addition, 7.80% of all the farmers would wash agrochemical containers and use them at home, while 42.43% would wash and use them on their farms. Probit regression results showed that probability of reusing agrochemical containers was significantly influenced (p agrochemicals. PMID:29438333

  15. Screening of external hazards for NPP with bank type reactor. Modeling of safety related systems and equipment for RBMK. Probabilistic assessment of NPP safety on aircraft impact. Progress report

    International Nuclear Information System (INIS)

    Kostarev, V.

    1999-01-01

    This progress report was produced within the frame of IAEA research project on screening the hazards for NPP with bank type reactor. It covers the following tasks; development of the model for the primary loop system of RBMK; developing the models for safety related equipment of RBMK; developing of models for safety related models of EGP-6 type reactor (Bilibinskaya Nuclear Co-generated heat and Power Plant); and probabilistic assessment of NPP safety on aircraft impact

  16. 41 CFR 102-34.250 - Do Federal employees in Government motor vehicles have to use all safety devices and follow all...

    Science.gov (United States)

    2010-07-01

    ... safety devices and follow all safety guidelines? Yes, Federal employees in Government motor vehicles have... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Do Federal employees in Government motor vehicles have to use all safety devices and follow all safety guidelines? 102-34.250 Section...

  17. Cocoa Farmers’ Compliance with Safety Precautions in Spraying Agrochemicals and Use of Personal Protective Equipment (PPE in Cameroon

    Directory of Open Access Journals (Sweden)

    Abayomi Samuel Oyekale

    2018-02-01

    Full Text Available The inability of farmers to comply with essential precautions in the course of spraying agrochemicals remains a policy dilemma, especially in developing countries. The objectives of this paper were to assess compliance of cocoa farmers with agrochemical safety measures, analyse the factors explaining involvement of cocoa farmers in the practice of reusing agrochemical containers and wearing of personal protective equipment (PPE. Data were collected with structured questionnaires from 667 cocoa farmers from the Centre and South West regions in Cameroon. Data analyses were carried out with Probit regression and Negative Binomial regression models. The results showed that average cocoa farm sizes were 3.55 ha and 2.82 ha in South West and Centre regions, respectively, and 89.80% and 42.64% complied with manufacturers’ instructions in the use of insecticides. Eating or drinking while spraying insecticides and fungicides was reported by 4.20% and 5.10% of all farmers in the two regions, respectively. However, 37.78% and 57.57% of all farmers wore hand gloves and safety boots while spraying insecticides in the South West and Centre regions of Cameroon, respectively. In addition, 7.80% of all the farmers would wash agrochemical containers and use them at home, while 42.43% would wash and use them on their farms. Probit regression results showed that probability of reusing agrochemical containers was significantly influenced (p < 0.05 by region of residence of cocoa farmers, gender, possession of formal education and farming as primary occupation. The Negative Binomial regression results showed that the log of number PPE worn was significantly influenced (p < 0.10 by region, marital status, attainment of formal education, good health, awareness of manufacturers’ instructions, land area and contact index. It was among others concluded that efforts to train farmers on the need to be familiar with manufacturers’ instructions and use PPE would enhance

  18. Field Safety Notes in Product Problems of Medical Devices for Use in Pulmonology.

    Science.gov (United States)

    Hannig, Jürgen; Siekmeier, Rüdiger

    2015-01-01

    The current European system for medical devices is governed by three EC directives: the Medical Device Directive 93/42/EEC, the In-Vitro Diagnostic Directive 98/79/EC and the Active Implantable Medical Device Directive 90/385/EEC and regulates marketing and post-market surveillance of medical devices in the European Economic Area. In cases of incidents and field safety corrective actions (FSCA) manufacturers have to inform the responsible Competent Authority, which is the Federal Institute for Drugs and Medical Devices (BfArM) and the public by field safety notices (FSN). In this study we analyzed FSN of medical devices exclusively serving for diagnostics or treatment in pulmonology (e.g. nebulizers, oxygen concentrators, pulse oximeters, lung function analyzers, and non-active devices for treatment). FSCA and FSN publicized by BfArM in 2005-2013 were analyzed in respect to the MEDDEV 2.12-1 rev 8. In total 41 FSCA were publicized for the included products. German and English FSN were found in 36/35 cases, respectively. FSN were clearly characterized as FSN in 22/20 cases and declaration of the type of action was found in 27/26 cases, respectively. Product names were provided in all cases. Lot numbers or other information for product characterization were available in 7/8 and 26/24 cases, respectively. Detailed information regarding FSCA and product malfunction were found in 27/33 and 36/35 cases, respectively. Information on product related risks with previous use of the affected product was provided in 24/23 cases. In 34/34 cases manufacturers provided information to mitigate product related risks. Requests to pass FSN to persons needing awareness were found in 10/14 cases. Contact data were provided in 30/30 cases. Confirmation that the Competent Authority was informed was found in 12/14 cases and in 19/18 cases a customer confirmation was included. The obtained data suggest that there is an increasing annual number of FSCA and most FSN fulfill the criteria of

  19. Monitoring readiness of safety relevant devices in nuclear power plants by means of CRT-colour displays

    International Nuclear Information System (INIS)

    Haubert, R.; Stokke, R.

    1980-01-01

    The development of an information system for monitoring readiness of safety relevant devices is encouraged by the requirements of KTA-rule 3501 (DIN 25434), which states in section 4.9.1.1. 'A display shall be provided for giving a survey of the condition of the components of the reactor protection system and the active engineered safeguards including their energy and auxiliary media supplies'. In the first stage of the development which was reported at the Enlarged Halden Programme Group Meeting in Loen, Norway, 5th-9th June, 1978, only the components of parts of a BWR-protection system were considered and no display was provided. This paper outlines the next step in the development which comprises implementation of the active engineered safeguards into the system and development of a display system based on a colour CRT-screen. A prototype of this computer-based system for monitoring of protection systems has been established, and it is planned to demonstrate this prototype system using the computer equipment at GRS, Garching (orig./HP)

  20. Safety catching device for pipe lines in missile shielding cylinders of nuclear power plants

    International Nuclear Information System (INIS)

    Hering, S.; Doll, B.

    1975-01-01

    The safety catching device for pipes in the missile shielding cylinders consists of a flexible steel cable surrounding the pipe in a distance in U-shape. The arrester cable - which works as a spring and is freely movable in all directions - is attached to the cylinder wall. For this, the ends of the cable are primarily fastened to anchor boxes which are then inserted in a stay tube with the same axis as the cable ends. The anchor boxes are fastened to the outer wall of the missile shielding cylinder by anchor bolts and holding plates. (DG/AK) [de

  1. Safety and efficacy of a low-cost glaucoma drainage device for refractory childhood glaucoma.

    Science.gov (United States)

    Kaushik, Sushmita; Kataria, Pankaj; Raj, Srishti; Pandav, Surinder Singh; Ram, Jagat

    2017-12-01

    To evaluate the safety and efficacy of a low-cost glaucoma drainage device (GDD), Aurolab aqueous drainage implant (AADI), similar in design to the Baerveldt glaucoma implant (BGI), in refractory childhood glaucoma. This prospective interventional study was conducted in a tertiary care postgraduate teaching institute. Children aged glaucoma valve implant in children. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. Device for increasing the safety in the environment of nuclear facilities in case of containment failure

    International Nuclear Information System (INIS)

    Morlock, G.; Wiesemes, J.; Bachner, D.

    1978-01-01

    In order to increase the safety in the environment of nuclear facilities, e.g. in case of containment failure, with respect to released radioactive material new or existing facilities are covered with ground. The ground material has got a consistency very much reducing the permeability for liquids and gases. In addition irrigation devices for keeping the ground wet and/or intermediate layers of films pervious to water, e.g. perforated sheets, may be provided. Additionally the ground is protected against frost. Especially suited for ground material is clay. (DG) [de

  3. [Rehabilitation of women suffering chronic cystitis in the postmenopausal period with the use of an AMUS-01 - Intramag apparatus equipped with a Rektomassazher device].

    Science.gov (United States)

    Azizov, A P; Azizova, P A; Beliaev, A A; Konova, A N; Raĭgorodskiĭ, Iu M

    2011-01-01

    The objective of the present study was to develop a rationale for the local treatment of chronic recurring cystitis in the postmenopausel period. To this effect, 76 patients at the mean age of 66.4 years with this pathology were examined and the data obtained were compared with observations of control postmenopausel women receiving traditional local substitution hormonal therapy. In the patients of the study group, this treatment was supplemented by intravaginal vibro-magnetotherapy and the conventional antibacterial therapy was replaced by local electrophoresis. All local physiotherapeutic procedures were performed with the use of a AMUS-01 - Intramag apparatus equipped with a Rektomassazher device an AMUS-01 - Intramag apparatus equipped with a Rektomassazher device. The immunological analysis of vaginal secretion coupled to bacterial and clinical investigations have demonstrated the advantages of the combined local treatment including physiotherapy. The integral efficacy index was by a factor of 1.8 higher than in the control group.

  4. Safety Analysis of 'Older/Aged' Handling and Transportation Equipment for Heavy Loads, Radioactive Waste and Materials in Accordance with German Nuclear Standards KTA 3902, 3903 and 3905

    International Nuclear Information System (INIS)

    Macias, P.; Prucker, E.; Stang, W.

    2006-01-01

    The purpose of this paper is to present a general safety analysis of important handling and transportation processes and their related equipment ('load chains' consisting of cranes, load-bearing equipment and load-attaching points). This project was arranged by the responsible Bavarian ministry for environment, health and consumer protection (StMUGV) in agreement with the power plant operators of all Bavarian nuclear power plants to work out potential safety improvements. The range of the equipment (e.g. reactor building, crane, refuelling machine, load-bearing equipment and load-attaching points) covers the handling and transportation of fuel elements (e. g. with fuel flasks), heavy loads (e.g. reactor pressure vessel closure head, shielding slabs) and radioactive materials and waste (e.g. waste flasks, control elements, fuel channels, structure elements). The handling equipment was subjected to a general safety analysis taking into account the ageing of the equipment and the progress of standards. Compliance with the current valid requirements of the state of science and technology as required by German Atomic Act and particularly of the nuclear safety KTA-standards (3902, 3903 and 3905) was examined. The higher protection aims 'safe handling and transportation of heavy loads and safe handling of radioactive materials and waste' of the whole analysis are to avoid a criticality accident, the release of radioactivity and inadmissible effects on important technical equipment and buildings. The scope of the analysis was to check whether these protection aims were fulfilled for all important technical handling and transportation processes. In particularly the design and manufacturing of the components and the regulations of the handling itself were examined. (authors)

  5. Design of hoisting device used in nuclear power plants. KTA safety engineering code. Draft amendment, as of 6/98

    International Nuclear Information System (INIS)

    1998-06-01

    The draft amendment specifies, according to the hazards involved, (a) the general provisions, (b) additional provisions supplementing the general provisions, (c) more stringent provisions relating to aggravated risks, applicable to lifting gear, and (d) additional requirements for elevators in reactor containments and refuelling equipment, to be taken into account in the design of hoisting device used in nuclear power plants. The term hoisting device in this context covers elevators, cranes, winches, trolleys, load carrying equipment, and LWR refuelling machines as are used in nuclear power plants. (orig./CB) [de

  6. The collection, storage and use of equipment performance data for the safety and reliability assessment of nuclear power plants

    International Nuclear Information System (INIS)

    Fothergill, C.D.H.

    1975-01-01

    It has been characteristic of the Nuclear Industry that it should grow up in an atmosphere where reliability and operational safety considerations have been of vital importance. Consequently all aspects of Nuclear Power Reactor design, construction and operation (in the U.K.A.E.A.) are subjected to rigorous reliability assessments, beginning with the automatic protective devices and the safety shut-down systems. This has resulted in the setting up of large and small private data stores to support this upsurgence of Safety and Reliability assessment work. Unfortunately, much of the information being stored and published falls short of the minimum requirements of Safety Assessors and Reliability Analysts who need to make use of it. That there is still an urgent need for more work to be done in the Reliability Data field is universally acknowledged. The characteristics which make up good quality reliability data must be defined and achievable minimum standards must be set for its identification, collection, storage and retrieval. To this end the United Kingdom Atomic Energy Authority have set up the Systems Reliability Service Data Bank. This includes a computerized storage facility comprised of two principal data stores: (i) Reliability Data Store, (ii) Event Data Store. The figures available in the Reliability Data Store range from those relating to the lifetimes of minute components to those obtained from the assessment of whole plants and complete assemblies. These data have been accumulated from many reliable sources both inside and outside the Nuclear Industry, including the transfer of 'live' data generated from the results of reliability surveillance exercises associated with Event Data collection. Computer techniques developed specifically for the Reliability Data Store enable further 'processing' of these data to be carried out. The Event Data Store consists of three discrete computerized data stores, each one providing the necessary storage, retrieval and

  7. ALARA issues arising for safety and security of radiation sources and security screening devices - Summary and recommendations of the 12. European ALARA network workshop

    International Nuclear Information System (INIS)

    Shaw, P.; Crouail, P.; Drouet, F.

    2010-01-01

    The 12. European ALARA Network (EAN) workshop on 'ALARA issues arising for safety and security of radiation sources and security screening devices' took place in Vienna (Austria) in October 2009. The aim of that workshop was to consider how the implementation of ALARA3, in terms of planned and emergency situations, involving worker and public doses, is affected by the introduction of security-related measures. In the case of new equipment and procedures, there was also the question of whether exposures arising from security screening devices can be justified and optimised. This workshop consisted of invited oral presentations, which highlighted the main issues, and half of the programme was devoted to discussions within working groups on specific topics. During their discussions, the working groups identified recommendations dealing with the following topics: the implementation of the Code of Conduct and HASS4 - ensuring ALARA; balancing security and safety - how to achieve an optimum solution; the management of an emergency exposure situation from an ALARA perspective; the justification and optimisation of the use of security devices. The objective of this paper is to present the main conclusions and recommendations produced during the workshop. Individual presentations (papers and slides) as well as the reports from the working groups are available to download on the EAN web site (http://www.eu-alara.net). (authors)

  8. Hoisting appliances and fuel handling equipment at nuclear facilities

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1988-12-31

    The guide is followed by the Finnish Centre for Radiation and Nuclear Safety (STUK) in regulating hoisting and handling equipment Class 3 at nuclear facilities. The guide is applied e.g. to the following equipment: reactor building overhead cranes, hoisting appliances at nuclear fuel storages, fuel handling machines, other hoisting appliances, which because of nuclear safety aspects are classified in Safety Class 3, and load-bearing devices connected with the above equipment, such as replaceable hoisting tools and auxiliary lifting devices. The regulating of hoisting and handling equipment comprises the following stages: handling of preliminary and final safety analysis reports, inspection of the construction plan, supervision of fabrication and construction inspection, and supervision of initial start-up and commissioning inspection. 36 refs. Translation. The original text is published under the same guide number. The guide is valid from 5 January 1987 and will be in force until further notice.

  9. Hoisting appliances and fuel handling equipment at nuclear facilities

    International Nuclear Information System (INIS)

    1987-01-01

    The guide is followed by the Finnish Centre for Radiation and Nuclear Safety (STUK) in regulating hoisting and handling equipment Class 3 at nuclear facilities. The guide is applied e.g. to the following equipment: reactor building overhead cranes, hoisting appliances at nuclear fuel storages, fuel handling machines, other hoisting appliances, which because of nuclear safety aspects are classified in Safety Class 3, and load-bearing devices connected with the above equipment, such as replaceable hoisting tools and auxiliary lifting devices. The regulating of hoisting and handling equipment comprises the following stages: handling of preliminary and final safety analysis reports, inspection of the construction plan, supervision of fabrication and construction inspection, and supervision of initial start-up and commissioning inspection

  10. Visual communication and terminal equipment

    International Nuclear Information System (INIS)

    Kang, Cheol Hui

    1988-06-01

    This book is divided two parts about visual communication and terminal equipment. The first part introduces visual communication, which deals with foundation of visual communication, technique of visual communication, equipment of visual communication, a facsimile and pictorial image system. The second part contains terminal equipment such as telephone, terminal equipment for data transmission on constitution and constituent of terminal equipment for data transmission, input device and output device, terminal device and up-to-date terminal device.

  11. Visual communication and terminal equipment

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Cheol Hui

    1988-06-15

    This book is divided two parts about visual communication and terminal equipment. The first part introduces visual communication, which deals with foundation of visual communication, technique of visual communication, equipment of visual communication, a facsimile and pictorial image system. The second part contains terminal equipment such as telephone, terminal equipment for data transmission on constitution and constituent of terminal equipment for data transmission, input device and output device, terminal device and up-to-date terminal device.

  12. High field MRI: safety and protection problems related to the installation and the management of a 4T equipment

    International Nuclear Information System (INIS)

    Russo, A.; Speranza, A.; DELIA, R.; ANTOLINI, R.; FERRARI, P.; FILIPPI, M.

    2006-01-01

    The Physics Department of Trento University (Italy), in collaboration with Bruker Biospin decided to set up a 4 T MR system for research in the neurological field as well as on the biological effects of high field MRI. Nowadays the number of similar apparatus set up in the world is very low, several of these operate in the USA, some in Australia and one in Israel. Due to the very low diffusion of these equipments and to the few knowledge today available about the biological effects by clinical application of high field MRI, the problems related to the installation of the apparatus from the safety point of view are not well standardized. Therefore, in Trento, it has been necessary to deal with many problems regarding the set up of the MRI apparatus, taking also into account the current law in Italy with respect the safety and protection in MRI applications. In the present paper the Authors show the carried out studies and analyses, in relation to the organization of the safety aspects. These studies have resulted in arranging specific guidelines for: working in controlled way; emergency procedures for the patient advanced life support; procedures for the protocol of patient protection; rules for the safety of the operators, patients and general public. The carried out analyses have mainly taken into account the danger identification and the risk evaluation. For this reason it was set up a test protocol regarding:the performing tests, the very detailed test modalities for their periodic performance and the test sequence. For the patient safety and protection it has been necessary to put care, in the first step of the survey, to the subjects in critical situations, due to: working activity, clinical history, health conditions of the patient at the moment of the examination. So it has been necessary to set up an anamnesis questionnaire for the patient, finalized to spot: (1) the patients with particular contraindications for the MR examination; (2) the patients which

  13. High field MRI: safety and protection problems related to the installation and the management of a 4T equipment

    Energy Technology Data Exchange (ETDEWEB)

    Russo, A.; Speranza, A. [National Research Council, Institute of Bioimaging and Biostructures- Dep.of Biomorphological and Functional Sciences - University Federico II, Napoli (Italy); DELIA, R. [University of Rome - Medicine and Surgery Faculty - La Sapienza Sez. Rieti (Italy); ANTOLINI, R. [University of Trento - Department of Physics, Trento (Italy); FERRARI, P. [University of Trento - Direction of Polo di Rovereto, Trento (Italy); FILIPPI, M. [University of Trento Prevention and Protection Service, Trento (Italy)

    2006-07-01

    The Physics Department of Trento University (Italy), in collaboration with Bruker Biospin decided to set up a 4 T MR system for research in the neurological field as well as on the biological effects of high field MRI. Nowadays the number of similar apparatus set up in the world is very low, several of these operate in the USA, some in Australia and one in Israel. Due to the very low diffusion of these equipments and to the few knowledge today available about the biological effects by clinical application of high field MRI, the problems related to the installation of the apparatus from the safety point of view are not well standardized. Therefore, in Trento, it has been necessary to deal with many problems regarding the set up of the MRI apparatus, taking also into account the current law in Italy with respect the safety and protection in MRI applications. In the present paper the Authors show the carried out studies and analyses, in relation to the organization of the safety aspects. These studies have resulted in arranging specific guidelines for: working in controlled way; emergency procedures for the patient advanced life support; procedures for the protocol of patient protection; rules for the safety of the operators, patients and general public. The carried out analyses have mainly taken into account the danger identification and the risk evaluation. For this reason it was set up a test protocol regarding:the performing tests, the very detailed test modalities for their periodic performance and the test sequence. For the patient safety and protection it has been necessary to put care, in the first step of the survey, to the subjects in critical situations, due to: working activity, clinical history, health conditions of the patient at the moment of the examination. So it has been necessary to set up an anamnesis questionnaire for the patient, finalized to spot: (1) the patients with particular contraindications for the MR examination; (2) the patients which

  14. Statistical analysis of the behaviour of the mechanical equipment of EDFs power plants - evaluation of the availability and safety of thermal and nuclear units

    International Nuclear Information System (INIS)

    Procaccia, H.; Brillon, A.; Cravero, M.; Lucenet, G.

    1975-01-01

    The investigation and research directorate of EDF has undertaken a statistical analysis of the behaviour of large mechanical equipment at conventional power stations during the ten years following the operating reports of these stations. It has thus been possible to determine the intrinsic reliability, the failure rate, the mean repair time, and the mean good operating time of feed water reheating points, power turbines, pumps and boilers of the various EDF plants (125 and 250 MW) leading to a consideration of the feasibility of an extrapolation to present and future plants. Based on these elementary investigation two methods of calculation have been developed. One is used to assess the overall availability of a thermal or nuclear power station based on the knowledge of the failure rates of the equipment, each piece of equipment being associated with an idea of its technical importance in the functioning of the equipment. A numerical application is given for 125 and 250 MW conventional plants. The purpose of the other method is to estimate the operational safety of the safety equipment of nuclear power stations, based on the development of tree diagrams for faults in basic equipment. A numerical example is given for the cooling systems for Phenix and for one of the Super Phenix versions. (author)

  15. Considerations concerning the reliability of reactor safety equipment; Considerations sur la fiabilite des ensembles de securite de reacteurs

    Energy Technology Data Exchange (ETDEWEB)

    Furet, J; Guyot, Ch [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires

    1967-07-01

    A review is made of the circumstances which favor a good collection of maintenance data at the C.E.A. The large amount of data to be treated has made necessary the use of a computer for analyzing automatically the results collected. Here, only particular aspects of the reliability from the point of view of the electronics used for nuclear reactor control will be dealt with: sale and unsafe failures; probability of survival (in the case of reactor safety); availability. The general diagrams of the safety assemblies which have been drawn up for two types of reactor (power reactor and low power experimental reactor) are given. Results are presented of reliability analysis which could be applied to the use of functional modular elements, developed industrially in France. Improvement of this reliability appears to be fairly limited by an increase in the redundancy; on the other hand it is shown how it may be very markedly improved by the use of automatic tests with different frequencies for detecting unsafe failures rates of measurements for the sub-assemblies and for the logic sub-assemblies. Finally examples are given to show the incidence of the complexity and of the use of different technologies in reactor safety equipment on the reliability. (authors) [French] On rappelle les circonstances qui favorisent au C.E.A. la collecte d'une information valable des resultats de la maintenance. L'importance des donnees a traiter a rendu necessaire l'utilisation d'une calculatrice poux l'analyse automatique des resultats recueillis. On se limitera ici aux aspects particuliers de la fiabilite du point de vue de l'electronique pour le controle et la commande de reacteurs nucleaires: pannes sures et pannes non sures; probabilite de survie dans le cas de la securite des reacteurs; facteur de disponibilite. Les schemas de principe des ensembles de securite definis pour deux types de reacteurs (reacteur de puissance et reacteur experimental de faible puissance) sont indiques. On

  16. 'The Closer'-percutaneous vascular suture device: evaluation of safety and performance in neuroangiography

    International Nuclear Information System (INIS)

    Henk, Christine B.; Grampp, Stephan; Heimberger, Karl; Czerny, Christian; Schindler, Erwin; Mostbeck, Gerhard H.

    2003-01-01

    Objective: To evaluate the use of the suture mediated vascular closure device concerning practicability and safety in clinical angiography practice. Material and methods: One hundred and seventeen patients (59 female, 58 male, mean age 40.9±13.4) underwent percutaneous closure of common femoral arterial puncture sites following diagnostic neuroangiography using the suture device 'the Closer' (Perclose Inc., Redwood City, CA, USA). Primary success, early problems (within 24 h) and late complications were evaluated. Complications were graded as minor and severe with or without need of surgical intervention and categorized by type. Parameters such as age, gender, sheath size and number of previous arterial punctures were evaluated with respect to complications. Results: Percutaneous closure was primary successful in 85% (100/117). The overall complication rate was 32% (28% mild n=35, 4% severe n=6, which needed surgical intervention). All but one problem occurred within the first 24 h after the suture. Additional manual compression was necessary in 32 cases (25%). There was no significant difference in age and gender between the groups with and without complications. Sheath size was significantly larger (P<0.01) and numbers of preceding angiograms were significantly higher (P<0.01) in the complications group compared with uncomplicated cases. Conclusion: The evaluated percutaneous vascular suture device is useful in clinical practice but limitations concerning patient selection seem to emerge in order to avoid complications

  17. Safety analysis of an irradiation device for 99Mo production in RA-3 reactor

    International Nuclear Information System (INIS)

    Lerner, Ana Maria; Madariaga, Marcelo; Waldman, Ricardo

    2000-01-01

    The Argentine RA-3 research reactor (5 MW) has been converted to LEU fuel more than nine years ago. Since then, it has been operating with LEU fuel, which has been designed and fabricated at the National Atomic Energy Commission (CNEA). The Nuclear Regulatory Authority (ARN) is the institution in charge of the installation safety control. It is under this framework that the ARN has elaborated a neutronic calculation model for the RA-3 core, paying special attention to the device presently used for the irradiation of (HEU) 235 U targets required to obtain 9 '9Mo as a fission product. A regulatory analysis of results is carried out in the framework of ARN standards for fixed experiments. For such purpose, calculated reactivity values associated with such device are compared with recently measured values at the installation. Finally, and according to guidelines established in the first part of this work, a calculation model for a new device proposed by CNEA for the irradiation of metallic (LEU) uranium targets and still at its design stage, is here analysed. (author)

  18. Nuclear criticality safety and time reactivity enhancement aspects of energy amplifier system devices

    Energy Technology Data Exchange (ETDEWEB)

    Siciliano, F [ENEA, Centro Ricerche Trisaia, Rotondelle, Matera (Italy). Direzione INFO

    1995-12-01

    As far as the Rubbia`s and colleagues proposal of innovating Energy Amplifier system (E.A.s.) device driven by a particle beam accelerator is concerned, four basic topics are comprised in the present paper: (1) A short outline of the nuclear aspects of Th-U and U-Pu fuel cycles regarding their general breeding and efficiency features. (2) The needed nuclear criticality control requirements have been studied in terms of safety regulating parameters on the basis of the ThO2 mixed oxides selected as fuel kind for the E.A.s. device technology development. Particular attention is devoted to time evolution of neutron multiplication factor since delayed development of the 233U buildup and so system reactivity are expected in the Th-U cycle. (3) Code E.A.s. device irradiation and post-irradiation modelling for determining higher actinides buildup, fission products formation and fuel consumption trends as function of time, system enrichment degree and flux level parameters. (4) The confirmation, on the basis of the same specific power irradiation, of expected actinides waste obtainment cleaner than the one deriving from the U-Pu cycle utilization. For this end, a model comparison of equivalent enriched fissile nuclides in both cycles has been devised as having, within the range of 0-700 days, ten irradiation periods of about 53 MW/ton specific power and equivalent cooling time post-irradiation periods.

  19. Hydrodynamics of Safety Injection Tank with Fluidic Device in Recent Regulation

    Energy Technology Data Exchange (ETDEWEB)

    Bang, Young Seok; Yoo, Seung Hun [Korea Institute of Nuclear Safety, Daejeon (Korea, Republic of)

    2016-10-15

    Safety Injection Tank (SIT) with Fluidic Device (FD) has been used in several APR1400 nuclear power plants. It was designed to provide a longer passive safety injection than the existing accumulator to improve the safety for Large Break Loss-of-Coolant Accident (LBLOCA) by changing the injected flow through the FD and the standpipe of the SIT. As a result, high flow injection phase and the subsequent low flow one can be achieved as longer than the existing accumulator. The present paper discusses the major concerns related to SIT hydrodynamics and the directions to resolution recently concerned. Modeling of SIT/FD by total hydraulic resistances, potential of nitrogen intrusion, and effect of initial pressure of SIT testing are included. Based on the discussion, a table of the important phenomena of the SIT/FD was proposed with the relevancy of the calculation models applied. The present paper discussed the SIT hydrodynamics including the modeling of SIT/FD by total hydraulic resistances, potential of nitrogen intrusion, and effect of initial pressure of SIT testing. Also a table of the important phenomena of the SIT/FD was proposed with the relevancy of the calculation models applied. The following conclusions are obtained uncertainty due to the assumption of the total Kfactor as constant for high flow, transition phase, and low flow phase should be considered and nitrogen intrusion phenomena during the transition phase should be considered with a conservatism, especially considering the current situation of nonmeasuring the standpipe level.

  20. Hydrodynamics of Safety Injection Tank with Fluidic Device in Recent Regulation

    International Nuclear Information System (INIS)

    Bang, Young Seok; Yoo, Seung Hun

    2016-01-01

    Safety Injection Tank (SIT) with Fluidic Device (FD) has been used in several APR1400 nuclear power plants. It was designed to provide a longer passive safety injection than the existing accumulator to improve the safety for Large Break Loss-of-Coolant Accident (LBLOCA) by changing the injected flow through the FD and the standpipe of the SIT. As a result, high flow injection phase and the subsequent low flow one can be achieved as longer than the existing accumulator. The present paper discusses the major concerns related to SIT hydrodynamics and the directions to resolution recently concerned. Modeling of SIT/FD by total hydraulic resistances, potential of nitrogen intrusion, and effect of initial pressure of SIT testing are included. Based on the discussion, a table of the important phenomena of the SIT/FD was proposed with the relevancy of the calculation models applied. The present paper discussed the SIT hydrodynamics including the modeling of SIT/FD by total hydraulic resistances, potential of nitrogen intrusion, and effect of initial pressure of SIT testing. Also a table of the important phenomena of the SIT/FD was proposed with the relevancy of the calculation models applied. The following conclusions are obtained uncertainty due to the assumption of the total Kfactor as constant for high flow, transition phase, and low flow phase should be considered and nitrogen intrusion phenomena during the transition phase should be considered with a conservatism, especially considering the current situation of nonmeasuring the standpipe level

  1. Electronic equipment and radioisotope devices developed in the Institute of Physics and Nuclear Techniques in the years 1975-1983

    International Nuclear Information System (INIS)

    1983-01-01

    A short review of 43 devices developed in the Institute of Physics and Nuclear Techniques of Academy of Mining and Metallurgy in the years 1975-1983 is given. 20 radioisotope arrangements, 14 electronic devices, 7 detectors for gas chromatography and X-ray detection as well as 2 arrangements for sample preparation are presented. (author)

  2. Electromagnetic interference from radio frequency identification inducing potentially hazardous incidents in critical care medical equipment

    NARCIS (Netherlands)

    Togt, R. van der; Lieshout, E.J. van; Hensbroek, R.; Beinat, E.; Binnekade, J.M.; Bakker, P.J.M.

    2008-01-01

    Context: Health care applications of autoidentification technologies, such as radio frequency identification (RFID), have been proposed to improve patient safety and also the tracking and tracing of medical equipment. However, electromagnetic interference (EMI) by RFID on medical devices has never

  3. Nuclear fast neutron reactor cooled by a liquid metal and of which internal structures are equipped with a thermal protection device

    International Nuclear Information System (INIS)

    Lemercier, G.; Lions, N.

    1986-01-01

    The internal structures of a nuclear fast neutron reactor are covered at least partially, on the most hot side, by a thermal protection device. This device comprises modular plates arranged end to end with a certain play between themselves and taking approximately the shape of the internal structures. Each plate is fixed in its center on the internal structures by a stud. A small plate fixed at one of the corners of each plate and covering partially the adjacent plates ensures the safety fixing of these ones [fr

  4. Guide On Safety Tests

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1987-05-15

    This book tells US important things to do safety tests, which includes basic caution for experiment treatment of used materials such as ignition substance inflammables, explosive substance and toxic substance, handling of used equipment like inflammable device, machine, high pressure device, high pressure gas, and high energy device, first aid such as addiction by drug, flame, radiation exposure, and heart massage treatment of waste in laboratory like cautions on general treatment, handling of inorganic waste, organic waste and waste treatment with disposal facilities.

  5. Guide On Safety Tests

    International Nuclear Information System (INIS)

    1987-05-01

    This book tells US important things to do safety tests, which includes basic caution for experiment treatment of used materials such as ignition substance inflammables, explosive substance and toxic substance, handling of used equipment like inflammable device, machine, high pressure device, high pressure gas, and high energy device, first aid such as addiction by drug, flame, radiation exposure, and heart massage treatment of waste in laboratory like cautions on general treatment, handling of inorganic waste, organic waste and waste treatment with disposal facilities.

  6. Ministerial Decision No 116 on the export of some materials, equipment and devices in the field of atomic energy

    International Nuclear Information System (INIS)

    1977-01-01

    This decision of the Ministry of Trade and Industry contains a list of equipment, facilities and materials other than nuclear materials the export of which requires a special permit in accordance with the Atomic Energy Act. The content of the list follows closely the trigger list defined by Memorandum B in the Appendix to IAEA document INFCIRC/209. (NEA) [fr

  7. Developments of radiation safety requirements for the management of radiation devices

    International Nuclear Information System (INIS)

    Lee, Hee Seock; Choi, Jin Ho; Cheong, Yuon Young

    2002-03-01

    The approach of the risk-informed regulatory options was studied to develop the radiation safety requirements for the managements for radiation devices. The task analysis, exposure, accident scenario development, risk analysis, and systematic approach for regulatory options was considered in full, based on the NRC report, 'NUREG/CR-6642', and the translation of its core part was conducted for ongoing research. In this methodology, the diamond tree that includes human factors, etc, additionally with normal event tree, was used. According to the analysis results of this approach, the risk analysis and the development of regulatory options were applied for the electron linear accelerators and the qualitative results were obtained. Because the field user groups were participated in this study could contribute to the basis establishment of the risk-informed regulation policy through securing consensus and inducing particle interests. It will make an important role of establishing the detail plan of ongoing research

  8. Safety implications of a graphite oxidation accident in the compact ignition tokamak device

    International Nuclear Information System (INIS)

    Merrill, B.J.; O'Brien, M.H.

    1989-01-01

    This paper addresses the possible safety consequences of an air ingress accident for the Compact Ignition Tokamak (CIT) device. An experimental program was undertaken to determine oxidation rates of four nuclear grade graphites in air at temperatures ranging from 800 to 1800 C and flow velocities from 3 to 7 m/s. On the basis of these test results, an analytic model was developed to assess the extent of first wall/divertor protective tile oxidation and the amount of energy released from this oxidation. For CIT, a significant restriction to vacuum vessel air inflow will be provided by the air seals and walls of the surrounding test cells. Under these conditions, the graphite oxidation reaction inside the vacuum vessel will become oxygen starved within minutes of the onset of this event. Since significant oxidation rates were not achieved, the heat release did not elevate structural temperatures to levels of concern with regard to activated material release. 7 refs., 9 figs

  9. Developments of radiation safety requirements for the management of radiation devices

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hee Seock [Pohang Accelerator Lab, Pohang (Korea, Republic of); Choi, Jin Ho [Gachun University of Medicine and science, Incheon (Korea, Republic of); Cheong, Yuon Young [Asan Medical Center, Seoul (Korea, Republic of)] (and others)

    2002-03-15

    The approach of the risk-informed regulatory options was studied to develop the radiation safety requirements for the managements for radiation devices. The task analysis, exposure, accident scenario development, risk analysis, and systematic approach for regulatory options was considered in full, based on the NRC report, 'NUREG/CR-6642', and the translation of its core part was conducted for ongoing research. In this methodology, the diamond tree that includes human factors, etc, additionally with normal event tree, was used. According to the analysis results of this approach, the risk analysis and the development of regulatory options were applied for the electron linear accelerators and the qualitative results were obtained. Because the field user groups were participated in this study could contribute to the basis establishment of the risk-informed regulation policy through securing consensus and inducing particle interests. It will make an important role of establishing the detail plan of ongoing research.

  10. On the choice of structures of equipment for preliminary data processing for a data acquisition subsystem of the automation control system for controlling technological parameters of tokamak devices

    International Nuclear Information System (INIS)

    Bondarenko, I.M.; Gerasimov, V.P.; Mozin, I.V.; Repin, S.S.; Skosarev, V.A.

    1982-01-01

    The necessity is substantiated to use a complex approach to constructing measuring channels of data acquisition subsystems in automation control systems for controlling technological processes in tokamak thermonuclear installations including preliminary data processing equipment, incorporated devices and measuring converters, which enables to minimize the whole bulk of equipment units, while attaining the best metrological features of the channels. Some examples are given designing measuring channels for different kind of signals. Special attention is paid to the choice of structures of measuring channels for signals from sensors under high voltage isolated from the ground potential. It is found reasonable to use analog-time data conversion and optoelectronic isolating elements from the viewpoint of simplicity of apparatus, good manufacturing technology and adjusting measuring channels elements

  11. Modernization of Unit 2 at Oskarshamn NPP- Main Objectives, Experience from Design, Separation of Operational and Nuclear Safety Equipment - Lessons Learned

    International Nuclear Information System (INIS)

    Kanaan, Salah K.

    2015-01-01

    This paper aims to give a picture of Oskarshamn Nuclear Power Plant (OKG) experience from design for one of the biggest modernization project in the world and focuses on what was learned that is specific to robustness of electrical power systems, especially through Fukushima Station Blackout (SBO). The planning for unit 2 at OKG was initiated in 1967 and the plant was completed on time and was synchronized to the grid October 2, 1974 and is of type BWR. Unit 2 was originally on 580 MW. In 1982 a thermal power up-rate was performed, from 1700 MWh to 1800 MWh (106% reactor output). A decision was made to perform a modernization and a new power up-rate to 850 MW and there were several reasons for this decision; New safety regulations from Swedish Radiation Safety Authority (SSM), Ageing of important components and the initial focus was on safety and availability - Project Plant Life Extension (Plex) was established and became the largest nuclear power modernization in the world. The modernization will lead to: - New safety concept with 4 divisions instead for existing 2 with 2 new buildings South Electrical Building (SEB) and North Electrical Building (NEB); - Completely new software - based equipments for monitoring, control and I and C; - New Low Pressure Turbine, new generator and main transformer; - New MCR and simulator; - Compliance with modern reactor safety requirements; - Redundancy, Separation, Diversification, Earthquake; - Reinforcement of existing safety functions; - New Electricity - I and C (electric power incl. reinforced emergency power and control systems); - New buildings for Electricity - I and C; - Reinforcement of existing process systems as well as installation of new ones. Based on studies and good experiences on how to separate the operational and the safety equipment, the project led to a completely new safety concept. The safety concept is based on fully understanding the safety system that shall encompass all of the elements required to

  12. "Do-It-Yourself" reliable pH-stat device by using open-source software, inexpensive hardware and available laboratory equipment.

    Science.gov (United States)

    Milanovic, Jovana Z; Milanovic, Predrag; Kragic, Rastislav; Kostic, Mirjana

    2018-01-01

    In this paper, we present the construction of a reliable and inexpensive pH stat device, by using open-source "OpenPhControl" software, inexpensive hardware (a peristaltic and a syringe pump, Arduino, a step motor…), readily available laboratory devices: a pH meter, a computer, a webcam, and some 3D printed parts. We provide a methodology for the design, development and test results of each part of the device, as well as of the entire system. In addition to dosing reagents by means of a low-cost peristaltic pump, we also present carefully controlled dosing of reagents by an open-source syringe pump. The upgrading of the basic open-source syringe pump is given in terms of pump control and application of a larger syringe. In addition to the basic functions of pH stat, i.e. pH value measurement and maintenance, an improvement allowing the device to be used for potentiometric titration has been made as well. We have demonstrated the device's utility when applied for cellulose fibers oxidation with 2,2,6,6-tetramethylpiperidine-1-oxyl radical, i.e. for TEMPO-mediated oxidation. In support of this, we present the results obtained for the oxidation kinetics, the consumption of added reagent and experimental repeatability. Considering that the open-source scientific tools are available to everyone, and that researchers can construct and adjust the device according to their needs, as well as, that the total cost of the open-source pH stat device, excluding the existing laboratory equipment (pH meter, computer and glossary) was less than 150 EUR, we believe that, at a small fraction of the cost of available commercial offers, our open-source pH stat can significantly improve experimental work where the use of pH stat is necessary.

  13. Personal Protective Equipment

    National Research Council Canada - National Science Library

    1998-01-01

    ... of personal protective equipment A safety program for new employees is a necessary part of any orientation program An on-going safety program should be used to motivate employees to continue to use...

  14. On the effect of the near field records on the steel braced frames equipped with energy dissipating devices

    Directory of Open Access Journals (Sweden)

    Mahmoud Bayat

    Full Text Available The behavior of braced steel frame structures is of special importance due to its extensive use. Also the application of active and semi-active control systems, regarding to their benefits in obtaining better seismic performance has increased significantly. The majority of the works on steel structures and steel connections has been done under far field records, and the behavior of steel frame structures equipped with yielding dampers under these circumstances has not yet been fully analyzed. The main purpose of this paper is to determine the behavior of structures equipped with yielding dampers, located in near field based on energy concepts. In order to optimize their seismic behavior, the codes and solutions are also presented.The selected system is a braced steel frame system which is equipped with yielding dampers and the analysis is performed using the "Perform 3D V.4" software and the conclusions are drawn upon energy criterion. The effect of PGA variation and height of the frames are also considered in the study .Finally, using the above mentioned results, a proper solution is presented for typical systems in order to increase the energy damping ability and reduce the destructive effects in structures on an earthquake event, so that a great amount of induced energy is damped and destruction of the structure is prevented as much as possible.

  15. α-spectrometric device equipped with semi-conductors for direct measurement of transuranium elements on large area filters

    International Nuclear Information System (INIS)

    Fessler, H.; Pawelzik, J.

    1984-10-01

    A device was developed with an array of 8 silicon surface barrier detectors inside a vacuum chamber containing a rotating sample holder for large areas (200 mm diameter) aerosol filters. It serves for quick identification of α-emitters on these aerosol filters, and allows to measure the α-particles with a relatively constant efficiency along a filter diameter. Thus, the radiochemical treatment of single filters can be avoided. Troubles appeared in the course of development of defective semiconductors and their temperature dependence. To suppress the influence of temperature a cooling device was built. During practical testing a cross-efficiency of 13.6% was measured. It is possible to identify α-emitting nuclides with an activity of 10 -1 Bq per sample during about 2 hours of measuring time. Appropriate methodes of calculation are indicated. The data output of the device is suited for transfer to a computer. (orig./HP) [de

  16. Safety, effectiveness and acceptability of the PrePex device for adult male circumcision in Kenya.

    Directory of Open Access Journals (Sweden)

    Paul J Feldblum

    Full Text Available To assess the safety, effectiveness and acceptability of the PrePex device for adult medical male circumcision (MMC in routine service delivery in Kenya.We enrolled 427 men ages 18-49 at one fixed and two outreach clinics. Procedures were performed by trained clinical officers and nurses. The first 50 enrollees were scheduled for six follow-up visits, and remaining men were followed at Days 7 and 42. We recorded adverse events (AEs and time to complete healing, and interviewed men about acceptability and pain.Placement and removal procedures each averaged between 3 and 4 minutes. Self-reported pain was minimal during placement but was fleetingly intense during removal. The rate of moderate/severe AEs was 5.9% overall (95% confidence interval [CI] 3.8%-8.5%, all of which resolved without sequelae. AEs included 5 device displacements, 2 spontaneous foreskin detachments, and 9 cases of insufficient foreskin removal. Surgical completion of MMC was required for 9 men (2.1%. Among the closely monitored first 50 participants, the probability of complete healing by Day 42 was 0.44 (95% CI 0.30-0.58, and 0.90 by Day 56. A large majority of men was favorable about their MMC procedure and would recommend PrePex to friends and family.The PrePex device was effective for MMC in Kenya, and well-accepted. The AE rate was higher than reported for surgical procedures there, or in previous PrePex studies. Healing time is longer than following surgical circumcision. Provider experience and clearer counseling on post-placement and post-removal care should lead to lower AE rates.ClinicalTrials.gov NCT01711411.

  17. Operating room fire prevention: creating an electrosurgical unit fire safety device.

    Science.gov (United States)

    Culp, William C; Kimbrough, Bradly A; Luna, Sarah; Maguddayao, Aris J

    2014-08-01

    To reduce the incidence of surgical fires. Operating room fires represent a potentially life-threatening hazard and are triggered by the electrosurgical unit (ESU) pencil. Carbon dioxide is a fire suppressant and is a routinely used medical gas. We hypothesize that a shroud of protective carbon dioxide covering the tip of the ESU pencil displaces oxygen, thereby preventing fire ignition. Using 3-dimensional modeling techniques, a polymer sleeve was created and attached to an ESU pencil. This sleeve was connected to a carbon dioxide source and directed the gas through multiple precisely angled ports, generating a cone of fire-suppressive carbon dioxide surrounding the active pencil tip. This device was evaluated in a flammability test chamber containing 21%, 50%, and 100% oxygen with sustained ESU activation. The sleeve was tested with and without carbon dioxide (control) until a fuel was ignited or 30 seconds elapsed. Time to ignition was measured by high-speed videography. Fires were ignited with each control trial (15/15 trials). The control group median ± SD ignition time in 21% oxygen was 3.0 ± 2.4 seconds, in 50% oxygen was 0.1 ± 1.8 seconds, and in 100% oxygen was 0.03 ± 0.1 seconds. No fire was observed when the fire safety device was used in all concentrations of oxygen (0/15 trials; P fire ignition was 76% to 100%. A sleeve creating a cone of protective carbon dioxide gas enshrouding the sparks from an ESU pencil effectively prevents fire in a high-flammability model. Clinical application of this device may reduce the incidence of operating room fires.

  18. Twenty-third water reactor safety information meeting. Volume 3, structural and seismic engineering, primary systems integrity, equipment operability and aging, ECCS strainer blockage research and regulatory issues

    Energy Technology Data Exchange (ETDEWEB)

    Monteleone, S. [comp.] [Brookhaven National Lab., Upton, NY (United States)

    1996-03-01

    This three-volume report contains papers presented at the Twenty- Third Water Reactor Safety Information Meeting held at the Bethesda Marriott Hotel, Bethesda, Maryland, October 23-25, 1995. The papers are printed in the order of their presentation in each session and describe progress and results of programs in nuclear safety research conducted in this country and abroad. Foreign participation in the meeting included papers presented by researchers from France, Italy, Japan, Norway, Russia, Sweden, and Switzerland. This document, Volume 3, presents topics in Structural & Seismic Engineering, Primary Systems Integrity, Equipment Operability and Aging, and ECCS Strainer Blockage Research & Regulatory Issues. Individual papers have been cataloged separately.

  19. Twenty-third water reactor safety information meeting. Volume 3, structural and seismic engineering, primary systems integrity, equipment operability and aging, ECCS strainer blockage research and regulatory issues

    International Nuclear Information System (INIS)

    Monteleone, S.

    1996-03-01

    This three-volume report contains papers presented at the Twenty- Third Water Reactor Safety Information Meeting held at the Bethesda Marriott Hotel, Bethesda, Maryland, October 23-25, 1995. The papers are printed in the order of their presentation in each session and describe progress and results of programs in nuclear safety research conducted in this country and abroad. Foreign participation in the meeting included papers presented by researchers from France, Italy, Japan, Norway, Russia, Sweden, and Switzerland. This document, Volume 3, presents topics in Structural ampersand Seismic Engineering, Primary Systems Integrity, Equipment Operability and Aging, and ECCS Strainer Blockage Research ampersand Regulatory Issues. Individual papers have been cataloged separately

  20. Test equipment used for radiation protection type testing of aerosol filters at the National Board of Nuclear Safety and Radiation Protection (SAAS)

    International Nuclear Information System (INIS)

    Ullmann, W.; Przyborowski, S.

    1977-01-01

    Following a description of the overall design of test equipment developed in the SAAS for radiation protection type testing of aerosol filters, the most important physical and technical details concerning the preparation and measurement of test aerosols as well as the sampling procedure upstream and downstream of the filter to the tested, are comprehensively discussed. Furthermore, experiences gained during several years with different devices for mixing and diluting the aerosols are reported. (author)

  1. "Do-It-Yourself" reliable pH-stat device by using open-source software, inexpensive hardware and available laboratory equipment

    Science.gov (United States)

    Kragic, Rastislav; Kostic, Mirjana

    2018-01-01

    In this paper, we present the construction of a reliable and inexpensive pH stat device, by using open-source “OpenPhControl” software, inexpensive hardware (a peristaltic and a syringe pump, Arduino, a step motor…), readily available laboratory devices: a pH meter, a computer, a webcam, and some 3D printed parts. We provide a methodology for the design, development and test results of each part of the device, as well as of the entire system. In addition to dosing reagents by means of a low-cost peristaltic pump, we also present carefully controlled dosing of reagents by an open-source syringe pump. The upgrading of the basic open-source syringe pump is given in terms of pump control and application of a larger syringe. In addition to the basic functions of pH stat, i.e. pH value measurement and maintenance, an improvement allowing the device to be used for potentiometric titration has been made as well. We have demonstrated the device’s utility when applied for cellulose fibers oxidation with 2,2,6,6-tetramethylpiperidine-1-oxyl radical, i.e. for TEMPO-mediated oxidation. In support of this, we present the results obtained for the oxidation kinetics, the consumption of added reagent and experimental repeatability. Considering that the open-source scientific tools are available to everyone, and that researchers can construct and adjust the device according to their needs, as well as, that the total cost of the open-source pH stat device, excluding the existing laboratory equipment (pH meter, computer and glossary) was less than 150 EUR, we believe that, at a small fraction of the cost of available commercial offers, our open-source pH stat can significantly improve experimental work where the use of pH stat is necessary. PMID:29509793

  2. Endovenous mechanochemical ablation of great saphenous vein incompetence using the ClariVein device: a safety study

    NARCIS (Netherlands)

    Eekeren, R. van; Boersma, D.; Elias, S.; Holewijn, S.; Werson, D.A.; Vries, J.P. de; Reijnen, M.M.P.J.

    2011-01-01

    PURPOSE: To evaluate the feasibility and safety of endovenous mechanochemical ablation (MOCA) for the treatment of great saphenous vein (GSV) incompetence. METHODS: The newly developed ClariVein device uses a technique that combines mechanical endothelial damage using a rotating wire with the

  3. Traffic sounds and cycling safety : the use of electronic devices by cyclists and the quietness of hybrid and electric cars.

    NARCIS (Netherlands)

    Stelling-Konczak, A. Hagenzieker, M.P. & Wee, B. van

    2015-01-01

    The growing popularity of electric devices and the increasing number of hybrid and electric cars have recently raised concerns about the use of auditory signals by vulnerable road users. This paper consolidates current knowledge about the two trends in relation to cycling safety. Both a literature

  4. The performance of a prototype device designed to evaluate general quality parameters of X-ray equipment

    Science.gov (United States)

    Murata, C. H.; Fernandes, D. C.; Lavínia, N. C.; Caldas, L. V. E.; Pires, S. R.; Medeiros, R. B.

    2014-02-01

    The performance of radiological equipment can be assessed using non-invasive methods and portable instruments that can analyze an X-ray beam with just one exposure. These instruments use either an ionization chamber or a state solid detector (SSD) to evaluate X-ray beam parameters. In Brazil, no such instruments are currently being manufactured; consequently, these instruments come at a higher cost to users due to importation taxes. Additionally, quality control tests are time consuming and impose a high workload on the X-ray tubes when evaluating their performance parameters. The assessment of some parameters, such as the half-value layer (HVL), requires several exposures; however, this can be reduced by using a SSD that requires only a single exposure. One such SSD uses photodiodes designed for high X-ray sensitivity without the use of scintillation crystals. This sensitivity allows one electron-hole pair to be created per 3.63 eV of incident energy, resulting in extremely high and stable quantum efficiencies. These silicon photodiodes operate by absorbing photons and generating a flow of current that is proportional to the incident power. The aim of this study was to show the response of the solid sensor PIN RD100A detector in a multifunctional X-ray analysis system that is designed to evaluate the average peak voltage (kVp), exposure time, and HVL of radiological equipment. For this purpose, a prototype board that uses four SSDs was developed to measure kVp, exposure time, and HVL using a single exposure. The reproducibility and accuracy of the results were compared to that of different X-ray beam analysis instruments. The kVp reproducibility and accuracy results were 2% and 3%, respectively; the exposure time reproducibility and accuracy results were 2% and 1%, respectively; and the HVL accuracy was ±2%. The prototype's methodology was able to calculate these parameters with appropriate reproducibility and accuracy. Therefore, the prototype can be considered

  5. Information booklet on personal protective equipment: eye and face protection

    International Nuclear Information System (INIS)

    1992-01-01

    In all work places where hazards of various kinds are present and the same cannot be totally controlled by engineering methods, suitable personal protective equipment (PPE) shall be used. There are several types of eye and face protection devices available in the market and it is important that employees use the proper type for the particular job. The main classes of eye and face protection devices required for the industrial operations are as follows: (a) eye protection devices which includes: (i) safety goggles (ii) safety spectacles (iii) safety clipons and eye and face protection devices which are (i) eye shield, (ii) face shield, (iii) wire mesh screen guard. Guide lines for selecting appropriate ear and face protection equipment for nuclear installations are given. (M.K.V.). 4 annexures, 1 appendix

  6. Feasibility and Safety of Endovascular Stripping of Totally Implantable Venous Access Devices

    International Nuclear Information System (INIS)

    Heye, Sam; Maleux, Geert; Goossens, G. A.; Vaninbroukx, Johan; Jerôme, M.; Stas, M.

    2012-01-01

    Purpose: To evaluate the safety and feasibility of percutaneous stripping of totally implantable venous access devices (TIVAD) in case of catheter-related sleeve and to report a technique to free the catheter tip from vessel wall adherence. Materials and Methods: A total of 37 stripping procedures in 35 patients (14 men, 40%, and 21 women, 60%, mean age 53 ± 14 years) were reviewed. Totally implantable venous access devices were implanted because of malignancy in most cases (85.7%). Catheter-related sleeve was confirmed as cause of persistent catheter dysfunction despite instillation of thrombolytics. A technique to mobilize the catheter tip from the vessel wall was used when stripping with the snare catheter was impossible. Technical success, complication rate, and outcome were noted. Results: A total of 55.9% (n = 19) of the 34 technically successful procedures (91.9%) could be done with the snare catheter. In 15 cases (44.1%), additional maneuvers to free the TIVAD’s tip from the vessel wall were needed. Success rate was not significantly lower before (72.4%) than after (96.7%) implementation of the new technique (P = 0.09). No complications were observed. Follow-up was available in 67.6% of cases. Recurrent catheter dysfunction was found in 17 TIVADs (78.3%) at a mean of 137.7 days and a median of 105 days. Conclusions: Stripping of TIVADs is technically feasible and safe, with an overall success rate of 91.9%. Additional endovascular techniques to mobilize the distal catheter tip from the wall of the superior vena cava or right atrium to allow encircling the TIVAD tip with the snare catheter may be needed in 44.1% of cases.

  7. Healthcare Provider Attitudes of Safety of Intrauterine Devices in the Postpartum Period.

    Science.gov (United States)

    Rauh-Benoit, Lisa A; Tepper, Naomi K; Zapata, Lauren B; Whiteman, Maura K; Curtis, Kathryn M; Mandel, Michele G; Marchbanks, Polly A; Jamieson, Denise J

    2017-07-01

    Immediate postpartum intrauterine devices (IUDs) have been underutilized in the United States despite their known safety. Understanding how providers' attitudes contribute to underutilization is important in improving access. Our objective was to examine healthcare providers' perceptions of the safety of immediate postpartum IUDs before publication of United States contraceptive guidelines. We analyzed survey data collected from December 2009 to March 2010 from 635 office-based physicians and 1368 Title X clinic providers (overall response rate of 64.8%). Providers were asked how safe they thought copper and levonorgestrel (LNG) IUDs were in postpartum women (very safe, safe, unsafe, very unsafe, and unsure). Multivariable logistic regression was used to calculate adjusted odds ratios (aORs) and 95% confidence intervals (95% CIs) for characteristics associated with considering immediate and delayed postpartum IUDs to be safe. Less than 40% of respondents considered immediate or delayed IUD insertion to be safe. Providers with postpartum IUD insertion to be safe compared with unsafe/unsure (aOR 0.18, 95% CI 0.04-0.84 for copper IUD and aOR 0.17, 95% CI 0.04-0.81 for LNG-IUD). Providers without training in postpartum or interval copper IUD insertion had decreased odds of considering immediate postpartum copper IUD insertion (aOR 0.40, 95% CI 0.16-0.79) and delayed postpartum insertion for both IUD types to be safe (aOR 0.34, 95% CI 0.18-0.66 for copper IUD and aOR 0.41, 95% CI 0.21-0.77 for LNG-IUD). Before United States contraceptive guidelines, a majority of providers perceived immediate postpartum IUDs to be unsafe.

  8. Development of Pneumatic Aerodynamic Devices to Improve the Performance, Economics, and Safety of Heavy Vehicles

    International Nuclear Information System (INIS)

    Robert J. Englar

    2000-01-01

    Under contract to the DOE Office of Heavy Vehicle Technologies, the Georgia Tech Research Institute (GTRI) is developing and evaluating pneumatic (blown) aerodynamic devices to improve the performance, economics, stability and safety of operation of Heavy Vehicles. The objective of this program is to apply the pneumatic aerodynamic aircraft technology previously developed and flight-tested by GTRI personnel to the design of an efficient blown tractor-trailer configuration. Recent experimental results obtained by GTRI using blowing have shown drag reductions of 35% on a streamlined automobile wind-tunnel model. Also measured were lift or down-load increases of 100-150% and the ability to control aerodynamic moments about all 3 axes without any moving control surfaces. Similar drag reductions yielded by blowing on bluff afterbody trailers in current US trucking fleet operations are anticipated to reduce yearly fuel consumption by more than 1.2 billion gallons, while even further reduction is possible using pneumatic lift to reduce tire rolling resistance. Conversely, increased drag and down force generated instantaneously by blowing can greatly increase braking characteristics and control in wet/icy weather due to effective ''weight'' increases on the tires. Safety is also enhanced by controlling side loads and moments caused on these Heavy Vehicles by winds, gusts and other vehicles passing. This may also help to eliminate the jack-knifing problem if caused by extreme wind side loads on the trailer. Lastly, reduction of the turbulent wake behind the trailer can reduce splash and spray patterns and rough air being experienced by following vehicles. To be presented by GTRI in this paper will be results developed during the early portion of this effort, including a preliminary systems study, CFD prediction of the blown flowfields, and design of the baseline conventional tractor-trailer model and the pneumatic wind-tunnel model

  9. Development of Pneumatic Aerodynamic Devices to Improve the Performance, Economics, and Safety of Heavy Vehicles

    Energy Technology Data Exchange (ETDEWEB)

    Robert J. Englar

    2000-06-19

    Under contract to the DOE Office of Heavy Vehicle Technologies, the Georgia Tech Research Institute (GTRI) is developing and evaluating pneumatic (blown) aerodynamic devices to improve the performance, economics, stability and safety of operation of Heavy Vehicles. The objective of this program is to apply the pneumatic aerodynamic aircraft technology previously developed and flight-tested by GTRI personnel to the design of an efficient blown tractor-trailer configuration. Recent experimental results obtained by GTRI using blowing have shown drag reductions of 35% on a streamlined automobile wind-tunnel model. Also measured were lift or down-load increases of 100-150% and the ability to control aerodynamic moments about all 3 axes without any moving control surfaces. Similar drag reductions yielded by blowing on bluff afterbody trailers in current US trucking fleet operations are anticipated to reduce yearly fuel consumption by more than 1.2 billion gallons, while even further reduction is possible using pneumatic lift to reduce tire rolling resistance. Conversely, increased drag and down force generated instantaneously by blowing can greatly increase braking characteristics and control in wet/icy weather due to effective ''weight'' increases on the tires. Safety is also enhanced by controlling side loads and moments caused on these Heavy Vehicles by winds, gusts and other vehicles passing. This may also help to eliminate the jack-knifing problem if caused by extreme wind side loads on the trailer. Lastly, reduction of the turbulent wake behind the trailer can reduce splash and spray patterns and rough air being experienced by following vehicles. To be presented by GTRI in this paper will be results developed during the early portion of this effort, including a preliminary systems study, CFD prediction of the blown flowfields, and design of the baseline conventional tractor-trailer model and the pneumatic wind-tunnel model.

  10. 21 CFR 866.4500 - Immunoelectrophoresis equipment.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents... clinical use with its electrical power supply is a device used for separating protein molecules...

  11. A clinical comparison of safety and efficacy in phacoemulsification with versus without ophthalmic viscoelastic device.

    Science.gov (United States)

    Kugu, Suleyman; Erdogan, Gurkan; Sahin Sevim, M; Ozerturk, Yusuf

    2015-03-01

    To evaluate in a comparative manner the safety and efficacy of 1.0% sodium-Hyaluronate used during capsulorhexis and intraocular lens (IOL) implantation in phacoemulsification surgery. 1.0% sodium-Hyaluronate, which is commonly used as one of the ophthalmic viscoelastic devices, was compared to intraocular irrigating solution, which can bring up these effects. In addition, the effect of both methods on occurring corneal endothelial cell (CEC) loss was investigated. Each group comprised 19 eyes. The mean preoperative CEC density was 2525.68 ± 181.85 in Group H and 2514.16 ± 174.59 in Group V; no statistically significant difference was found between the groups (p > 0.05). Preoperative and postoperative first and twelfth week CEC densities were 2438.21 ± 198.12 (p  0.05). Although it was found that there was no statistically difference in terms of preventing CEC loss between 1.0% sodium-Hyaluronate and the irrigation method during phacoemulsification, it was observed clinically that 1.0% sodium-hyaluronate can make the procedure easy, safer, very helpful, especially for understanding phacoemulsification.

  12. The impact of different types of assistive devices on gait measures and safety in Huntington's disease.

    Directory of Open Access Journals (Sweden)

    Anne D Kloos

    Full Text Available BACKGROUND: Gait and balance impairments lead to frequent falls and injuries in individuals with Huntington's disease (HD. Assistive devices (ADs such as canes and walkers are often prescribed to prevent falls, but their efficacy is unknown. We systematically examined the effects of different types of ADs on quantitative gait measures during walking in a straight path and around obstacles. METHODS: Spatial and temporal gait parameters were measured in 21 subjects with HD as they walked across a GAITRite walkway under 7 conditions (i.e., using no AD and 6 commonly prescribed ADs: a cane, a weighted cane, a standard walker, and a 2, 3 or 4 wheeled walker. Subjects also were timed and observed for number of stumbles and falls while walking around two obstacles in a figure-of-eight pattern. RESULTS: Gait measure variability (i.e., coefficient of variation, an indicator of fall risk, was consistently better when using the 4WW compared to other ADs. Subjects also walked the fastest and had the fewest number of stumbles and falls when using the 4WW in the figure-of-eight course. Subjects walked significantly slower using ADs compared to no AD both across the GAITRite and in the figure-of-eight. Measures reflecting gait stability and safety improved with the 4WW but were made worse by some other ADs.

  13. The impact of different types of assistive devices on gait measures and safety in Huntington's disease.

    Science.gov (United States)

    Kloos, Anne D; Kegelmeyer, Deborah A; White, Susan E; Kostyk, Sandra K

    2012-01-01

    Gait and balance impairments lead to frequent falls and injuries in individuals with Huntington's disease (HD). Assistive devices (ADs) such as canes and walkers are often prescribed to prevent falls, but their efficacy is unknown. We systematically examined the effects of different types of ADs on quantitative gait measures during walking in a straight path and around obstacles. Spatial and temporal gait parameters were measured in 21 subjects with HD as they walked across a GAITRite walkway under 7 conditions (i.e., using no AD and 6 commonly prescribed ADs: a cane, a weighted cane, a standard walker, and a 2, 3 or 4 wheeled walker). Subjects also were timed and observed for number of stumbles and falls while walking around two obstacles in a figure-of-eight pattern. Gait measure variability (i.e., coefficient of variation), an indicator of fall risk, was consistently better when using the 4WW compared to other ADs. Subjects also walked the fastest and had the fewest number of stumbles and falls when using the 4WW in the figure-of-eight course. Subjects walked significantly slower using ADs compared to no AD both across the GAITRite and in the figure-of-eight. Measures reflecting gait stability and safety improved with the 4WW but were made worse by some other ADs.

  14. New vision of the control organisms in industrial safety and maintenance, based approach to new pressure equipment

    International Nuclear Information System (INIS)

    Bernardez Garcia, A.

    2010-01-01

    Control agencies are companies dedicated to the verification of compliance with the safety of products and facilities as administrative regulation in industrial safety through certification activities, testing, inspection or audit.Changes have been made that will stimulate the increase of companies engaged in this sector.

  15. Wheeled mobility device transportation safety in fixed route and demand-responsive public transit vehicles within the United States.

    Science.gov (United States)

    Frost, Karen L; van Roosmalen, Linda; Bertocci, Gina; Cross, Douglas J

    2012-01-01

    An overview of the current status of wheelchair transportation safety in fixed route and demand-responsive, non-rail, public transportation vehicles within the US is presented. A description of each mode of transportation is provided, followed by a discussion of the primary issues affecting safety, accessibility, and usability. Technologies such as lifts, ramps, securement systems, and occupant restraint systems, along with regulations and voluntary industry standards have been implemented with the intent of improving safety and accessibility for individuals who travel while seated in their wheeled mobility device (e.g., wheelchair or scooter). However, across both fixed route and demand-responsive transit systems a myriad of factors such as nonuse and misuse of safety systems, oversized wheeled mobility devices, vehicle space constraints, and inadequate vehicle operator training may place wheeled mobility device (WhMD) users at risk of injury even under non-impact driving conditions. Since WhMD-related incidents also often occur during the boarding and alighting process, the frequency of these events, along with factors associated with these events are described for each transit mode. Recommendations for improving WhMD transportation are discussed given the current state of

  16. Sharps injuries in UK health care: a review of injury rates, viral transmission and potential efficacy of safety devices.

    Science.gov (United States)

    Elder, Alexander; Paterson, Caron

    2006-12-01

    To review the literature on sharps injuries and occupational bloodborne virus transmission in health care in the UK and the worldwide evidence for injury prevention of sharps safety devices. Literature review by online database and Internet resource search. Twenty-four relevant publications were identified regarding UK reported sharps injury rates. UK studies showed as much as a 10-fold difference between injuries reported through standard reporting systems (0.78-5.15 per 100 person-years) and rates estimated from retrospective questionnaires of clinical populations (30-284 per 100 person-years). National surveillance data from England, Wales and Northern Ireland gives a rate of 1.43 known hepatitis C virus or human immunodeficiency virus (HIV) transmissions to health care workers per annum. When extrapolated, this suggests an approximate rate of 0.009 such viral transmissions per 1000 hospital beds per annum. Risk of infection from sources with no risk factors is extremely small (less than one in one million for HIV transmission based on Scottish data). Thirty-one studies on the efficacy of sharps safety devices showed evidence of a reduction in injuries, with the greatest reductions achieved by blunt suture needles and safety cannulae. Although injuries remain common, confirmed viral transmission in the UK has been relatively rare. The degree of under-reporting of sharps injuries may be as much as 10-fold. Safety-engineered devices are likely to be effective at injury reduction.

  17. Basic concepts and issues: a primer on distribution and sales representative agreements in the medical device and durable medical equipment industries.

    Science.gov (United States)

    Burow, Heiko E; Kolls, Raymond C

    2006-01-01

    Counsel for a manufacturer of medical devices or durable medical equipment must have working knowledge of various legal disciplines to draft contracts with intermediaries (sales representatives and distributors) for the marketing and sale of the manufacturer's products. If the manufacturer wishes to sell its products abroad, counsel must become familiar with the laws and business practices of the target country, and methods of gaining access to the foreign market. This Article gives readers an overview of the applicable legal principles, under U.S. and foreign laws, in the areas of agency, contracts, healthcare regulation, consumer protection, intellectual property protection, and dealer protection. To aid counsel in drafting intermediary agreements, specific contractual terms and issues are explored in depth, including: appointment clauses, performance provisions, provisions concerning pricing and payment, protective clauses (shielding the manufacturer from liability), term and termination provisions, independent contractor clauses, export control clauses, recordkeeping and audit provisions, choice of law clauses, and dispute resolution clauses.

  18. Improving eye safety in citrus harvest crews through the acceptance of personal protective equipment, community-based participatory research, social marketing, and community health workers.

    Science.gov (United States)

    Tovar-Aguilar, J Antonio; Monaghan, Paul F; Bryant, Carol A; Esposito, Andrew; Wade, Mark; Ruiz, Omar; McDermott, Robert J

    2014-01-01

    For the last 10 years, the Partnership for Citrus Workers Health (PCWH) has been an evidence-based intervention program that promotes the adoption of protective eye safety equipment among Spanish-speaking farmworkers of Florida. At the root of this program is the systematic use of community-based preventive marketing (CBPM) and the training of community health workers (CHWs) among citrus harvester using popular education. CBPM is a model that combines the organizational system of community-based participatory research (CBPR) and the strategies of social marketing. This particular program relied on formative research data using a mixed-methods approach and a multilevel stakeholder analysis that allowed for rapid dissemination, effective increase of personal protective equipment (PPE) usage, and a subsequent impact on adoptive workers and companies. Focus groups, face-to-face interviews, surveys, participant observation, Greco-Latin square, and quasi-experimental tests were implemented. A 20-hour popular education training produced CHWs that translated results of the formative research to potential adopters and also provided first aid skills for eye injuries. Reduction of injuries is not limited to the use of safety glasses, but also to the adoption of timely intervention and regular eye hygiene. Limitations include adoption in only large companies, rapid decline of eye safety glasses without consistent intervention, technological limitations of glasses, and thorough cost-benefit analysis.

  19. [Hydrotherapy equipment].

    Science.gov (United States)

    Tsibikov, V B; Ragozin, S I; Mikheeva, L V

    1985-01-01

    A flow-chart is developed demonstrating the relation between medical and prophylactic institutions within the organizational structure of the rehabilitation system and main types of rehabilitation procedures. In order to ascertain the priority in equipping rehabilitation services with adequate hardware the special priority criterion is introduced. The highest priority is assigned to balneotherapeutic and fangotherapeutic services. Based on the operation-by-operation analysis of clinical processes related to service and performance of balneologic procedures the preliminary set of clinical devices designed for baths, basins and showers in hospitals and rehabilitation departments is defined in a generalized form.

  20. A systematic review of light-based home-use devices for hair removal and considerations on human safety

    DEFF Research Database (Denmark)

    Thaysen-Petersen, D; Bjerring, P; Dierickx, C

    2012-01-01

    To systematically review and evaluate the efficacy and human safety of currently available home-based optical hair removal devices. Methods A comprehensive Pub Med literature search was conducted which systematically identified publications of relevance. Prospective clinical trials were included whether controlled......, uncontrolled or randomized and with a sample size of at least 10 individuals. Results We identified a total of seven studies: one controlled (CT) and six uncontrolled trials (UCTs). No randomized controlled trials (RCT) were recognized. The best evidence was found for IPL (intense pulsed light) (three devices...

  1. Improving Patient Safety with X-Ray and Anesthesia Machine Ventilator Synchronization: A Medical Device Interoperability Case Study

    Science.gov (United States)

    Arney, David; Goldman, Julian M.; Whitehead, Susan F.; Lee, Insup

    When a x-ray image is needed during surgery, clinicians may stop the anesthesia machine ventilator while the exposure is made. If the ventilator is not restarted promptly, the patient may experience severe complications. This paper explores the interconnection of a ventilator and simulated x-ray into a prototype plug-and-play medical device system. This work assists ongoing interoperability framework development standards efforts to develop functional and non-functional requirements and illustrates the potential patient safety benefits of interoperable medical device systems by implementing a solution to a clinical use case requiring interoperability.

  2. Home Safe Home: Appliances, Tools, and Small Equipment. Proceed with Caution: Consumer Safety in the Home, III.

    Science.gov (United States)

    Saskatchewan Consumer and Commercial Affairs, Regina.

    Many accidents in the home are caused by faulty, defective or improperly designed tools, appliances, and equipment. Government, non-governmental organizations, and industries cooperate to develop and implement standards for the safe design and manufacture of consumer products. This booklet provides information to help consumers select products,…

  3. Improved Safety and Efficacy of Small-Bore Feeding Tube Confirmation Using an Electromagnetic Placement Device.

    Science.gov (United States)

    Powers, Jan; Luebbehusen, Michael; Aguirre, Lillian; Cluff, Julia; David, Mary Ann; Holly, Vince; Linford, Lorraine; Park, Nancy; Brunelle, Rocco

    2018-04-01

    Early enteral nutrition has been shown to decrease complications and improve patient outcomes. Post pyloric feeding is recommended for patients with gastric intolerance or at high risk for aspiration. Feeding tube placement can be challenging and pose risk of pulmonary complications. Reliance on radiographic confirmation for feeding tube placement exposes the patient to radiation. Electromagnetic placement device (EMPD) may offer a method to minimize pulmonary complications, increase successful placement, and decrease radiation exposure to the patient. The purpose of this study was to evaluate the safety and efficacy of using EMPD verification, instead of routine abdominal radiographic confirmation, for small-bore feeding tube placement. Variables evaluated were adverse events, utilization of radiographs for confirmation, and success rate of feeding tube placement in the ordered location. Two time frames were reviewed. In a 1-year period, 3754 small-bore feeding tubes were placed using EMPD, with zero adverse events noted. Radiographic confirmation was utilized in 0%-29.2% of the EMPD placed tubes. Successful placement of feeding tubes using EMPD ranged from 94%-99.6%. During a 5-year period, 7081 EMPD feeding tubes were evaluated. One adverse event, pneumothorax, occurred during the placement of these 7081 tubes, for a rate of 0.014%. Feeding tube placement confirmation is safe and efficacious via EMPD providing an effective method of feeding tube placement with a success rate >94% into the desired location. EMPD is an accurate verification method of distal tip location, eliminating the need for routine abdominal radiographic confirmation. © 2018 American Society for Parenteral and Enteral Nutrition.

  4. Recommended safety guides for industrial laboratories and shops

    Science.gov (United States)

    Allison, W. W.

    1971-01-01

    Booklet provides references to 29 publications providing information on hazard control and approved safety practices. Areas include pressurized gas and vacuum systems. Guidelines are presented for safeguarding facilities where machinery, equipment, electrical devices, or hazardous chemicals are used.

  5. Safety and effectiveness of repeat arterial closure using the AngioSeal device in patients with hepatic malignancy.

    Science.gov (United States)

    Hieb, Robert A; Neisen, Melissa J; Hohenwalter, Eric J; Molnar, Jim A; Rilling, William S

    2008-12-01

    To retrospectively evaluate the safety and effectiveness of the use of the AngioSeal device for repeat arterial closure in patients with hepatic malignancy. A retrospective analysis of patients with hepatic malignancy who had undergone repeated arterial closure with the AngioSeal device was performed. All charts for patients undergoing transarterial chemoembolization or TheraSphere radioembolization were reviewed for the method of hemostasis and the number of arterial closures. A total of 53 patients (58.5% men, 41.5% women; mean age, 58.7 years) had repeat AngioSeal arterial puncture closure after chemoembolization or TheraSphere treatment. Percutaneous closure of the common femoral artery with the AngioSeal device was performed in accordance with the manufacturer's recommendations. The patients were examined for complications on follow-up. Effectiveness was defined by the ability to obtain satisfactory hemostasis. Safety was assessed by the absence of groin complications and by vessel patency on follow-up angiograms of the puncture site obtained at subsequent liver-directed therapy sessions. Fifty-three patients in this study group had a total of 203 common femoral artery punctures. There were a total of 161 closures with the AngioSeal device (79.3%): 58 (36%) single closures and 103 (64.0%) repeat closures. Of the 161 attempts at AngioSeal closure, there was one closure failure in the single-puncture group, yielding a success rate of 98.3%; and one closure failure in the repeat-puncture group, yielding a success rate of 99%. In these two patients, hemostasis was achieved with traditional manual compression without the need for any other device, and no complications were noted. The overall success rate of AngioSeal device closure was 98.7%. The repeat use of the AngioSeal closure device is safe and effective in patients with hepatic malignancy undergoing regional oncologic interventional procedures.

  6. Recommended safety procedures for the selection and use of demonstration-type gas discharge devices in schools

    International Nuclear Information System (INIS)

    1979-01-01

    A 1972 survey of 30 Ottawa secondary schools revealed a total of 347 actual or potential X-ray sources available in these schools. More than half of these sources were gas discharge tubes. Some gas discharge tubes, in particular the cold cathode type, can emit X-rays at significantly high levels. Unless such tubes are used carefully, and with regard for good radiation safety practices, they can result in exposures to students that are in excess of the maximum levels recommended by the International Commission on Radiological Protection. Several cases of the recommended dose being exceeded were found in the classes surveyed. This document has been prepared to assist science teachers and others using demonstration-type gas discharge devices to select and use such devices so as to present negligible risk to themselves and students. Useful information on safety procedures to be followed when performing demonstrations or experiments is included. (J.T.A.)

  7. Probabilistic methods of optimization of scheduled tests for heat equipment of safety systems of reactor at full power

    International Nuclear Information System (INIS)

    Bilej, D.V.; Fridman, N.A.; Kolykhanov, V.N.; Skalozubov, V.I.

    2004-01-01

    This article generalises the basic results of a long-term teamwork with respect to a scientific and technical substantiation of perfection of the regulations of safe operation power units with VVER. This perfection is concerning a periodicity and volumes of tests of safety systems when a reactor works at full power. The article shows that the application of the probabilistic approaches connected to minimisation of a risk criterion function is an effective methodical base for the optimisation. For certain safety systems of serial power units with VVER 1000 the results of calculated substantiations are presented

  8. Benefits of Digital Equipment Generic Qualification Activities

    International Nuclear Information System (INIS)

    Thomas, James E.; Steiman, Samuel C.

    2002-01-01

    As a result of nuclear power plant instrumentation and control obsolescence issues, there have been numerous activities during recent years relating to the qualification of digital equipment. Some of these activities have been 'generic' in nature in that the qualification was not limited to plant specific applications, but was intended to cover a broad base of potential applications of the digital equipment. These generic qualifications have been funded by equipment manufacturers and by utility groups and organizations. The generic activities sponsored by the Electric Power Research Institute (EPRI) have been pilot projects for an overall generic qualification approach. The primary benefit resulting from the generic qualification work to date is that a number of digital platforms and digital devices are now available for use in various nuclear safety-related applications. Many of the tests and evaluations necessary to support plant specific applications have been completed. The amount of data and documentation that each utility must develop on a case by case basis has been significantly reduced. There are also a number of additional benefits resulting from these industry efforts. The challenges and difficulties in qualifying digital equipment for safety-related applications are now more clearly understood. EPRI has published a lessons learned document (EPRI Report 1001452, Generic Qualification of Commercial Grade Digital Devices: Lessons Learned from Initial Pilots, which covers several different qualification areas, including device selection, project planning, vendor surveys and design reviews, and electromagnetic compatibility (EMC) qualification. Application of the experience and lessons learned from the EPRI pilot activities should help reduce the effort and cost required for future qualification work. Most generic qualification activities for commercial equipment have been conducted using the approach of EPRI TR-106439, Guideline on Evaluation and Acceptance

  9. Association between Workplace and Housing Conditions and Use of Pesticide Safety Practices and Personal Protective Equipment among North Carolina Farmworkers in 2010

    Directory of Open Access Journals (Sweden)

    DL Levesque

    2012-03-01

    Full Text Available Background: There are inconsistencies about the effects of farmworker housing and workplace conditions and use of self-protective behavior practices and personal protective equipment (PPE. Objective: To investigate the association between workplace and housing conditions and farmworker use of pesticide safety practices and PPE. Methods: This study was conducted in 4 counties in North Carolina, USA, from July to October, 2010, during the agricultural growing season. Farmworkers working in agriculture aged 18 to 62 (n=187 were administered a structured questionnaire to collect self-reported measures on housing and workplace conditions. Use of pesticide safety and PPE were examined by asking questions about wearing gloves, wearing socks, and wearing a hat. Chi-square and multiple logistic regression analyses were used for statistical analyses. Results: Farmworkers reporting availability of enough hot and cold water for bathing and doing laundry were 13.6 times more likely to use pesticide safety practices (adjusted OR: 13.6, 95% CI: 1.4–135.4, whereas, those who reported that soap for handwashing was always or usually available while doing agricultural work were 7.8 times more likely to use pesticide safety practices (adjusted OR: 7.8, 95% CI: 3.3–18.5. Farmworkers that reported access to water to wash their hands with while performing agricultural work were more likely to use PPE (adjusted OR: 3.4, 95% CI: 1.3–9.2. Conclusions: Some migrant farmworker labor camps are not supplying acceptable housing conditions such as 1 handwashing sink per 6 people (n=10, 5.4%. Use of pesticide safety practices and PPE is greater when farmers provide decontamination supplies. Improvement of housing and workplace conditions are crucial to increase use of pesticide safety practices and PPE.

  10. Safety in the operating room during orthopedic trauma surgery-incidence of adverse events related to technical equipment and logistics

    NARCIS (Netherlands)

    van Delft, E. A. K.; Schepers, T.; Bonjer, H. J.; Kerkhoffs, G. M. M. J.; Goslings, J. C.; Schep, N. W. L.

    2017-01-01

    Safety in the operating room is widely debated. Adverse events during surgery are potentially dangerous for the patient and staff. The incidence of adverse events during orthopedic trauma surgery is unknown. Therefore, we performed a study to quantify the incidence of these adverse events. Primary

  11. Equipment maintenance as a tool for raising of safety and efficiency of the NPP'Kozloduy' operation

    International Nuclear Information System (INIS)

    Kichev, E.

    1999-01-01

    The role of the maintenance in the NPP management is discussed. The main links in the management are: NPP executives and their position; maintenance; quantitative characteristics of the maintenance. The described management process gives the opportunity the maintenance optimization on different levels: component, system, unit, plant. The results are valid for other areas with high safety requirements

  12. 10 CFR 50.49 - Environmental qualification of electric equipment important to safety for nuclear power plants.

    Science.gov (United States)

    2010-01-01

    ... important to safety for nuclear power plants. 50.49 Section 50.49 Energy NUCLEAR REGULATORY COMMISSION... nuclear power plants. (a) Each holder of or an applicant for an operating license issued under this part... nuclear power plant for which the certifications required under § 50.82(a)(1) or § 52.110(a)(1) of this...

  13. Engineering task plan for the annual revision of the rotary mode core sampling system safety equipment list

    International Nuclear Information System (INIS)

    BOGER, R.M.

    1999-01-01

    This Engineering Task Plan addresses an effort to provide an update to the RMCS Systems 3 and 4 SEL and DCM in order to incorporate the changes to the authorization basis implemented by HNF-SD-WM-BIO-001, Rev. 0 (Draft), Addendum 5 , Safety Analysis for Rotary Mode Core Sampling. Responsibilities, task description, cost estimate, and schedule are presented

  14. ''Safety rules of fatigue damage for nuclear facilities pressurized equipment at the sizing and the operation stage''

    International Nuclear Information System (INIS)

    Grandemange, J.M.; Faidy, C.

    2001-01-01

    This paper presents the method applied in the nuclear industry in the domain of the fatigue risk safety. It recalls the fatigue curves origins and presents the technical requirements implemented during the design and the construction. It also presents the follow-up of transients in service and the periodical examinations. (A.L.B.)

  15. Instructions included? Make safety training part of medical device procurement process.

    Science.gov (United States)

    Keller, James P

    2010-04-01

    Before hospitals embrace new technologies, it's important that medical personnel agree on how best to use them. Likewise, hospitals must provide the support to operate these sophisticated devices safely. With this in mind, it's wise for hospitals to include medical device training in the procurement process. Moreover, purchasing professionals can play a key role in helping to increase the amount of user training for medical devices and systems. What steps should you take to help ensure that new medical devices are implemented safely? Here are some tips.

  16. Process and device for reducing the presence in the safety containment of a nuclear reactor

    International Nuclear Information System (INIS)

    Stiefel, M.

    1981-01-01

    If faults occur, the excess pressure in the safety containment has to be reduced. Part of the gas contents of the safety containment is drawn off for this purpose. Hydrogen up to a maximum of 3.5% by volume is added to the drawn-off gas. The gas enriched with hydrogen is taken through a recombiner, where part of the oxygen content of the gas burns with the hydrogen, producing water. The gas with reduced oxygen content is returned to the safety containment via the free end of an annular pipe. The pressure existing in the safety containment is reduced according to the reduction in oxygen content. (orig./HP) [de

  17. SAFETY

    CERN Multimedia

    M. Plagge, C. Schaefer and N. Dupont

    2013-01-01

    Fire Safety – Essential for a particle detector The CMS detector is a marvel of high technology, one of the most precise particle measurement devices we have built until now. Of course it has to be protected from external and internal incidents like the ones that can occur from fires. Due to the fire load, the permanent availability of oxygen and the presence of various ignition sources mostly based on electricity this has to be addressed. Starting from the beam pipe towards the magnet coil, the detector is protected by flooding it with pure gaseous nitrogen during operation. The outer shell of CMS, namely the yoke and the muon chambers are then covered by an emergency inertion system also based on nitrogen. To ensure maximum fire safety, all materials used comply with the CERN regulations IS 23 and IS 41 with only a few exceptions. Every piece of the 30-tonne polyethylene shielding is high-density material, borated, boxed within steel and coated with intumescent (a paint that creates a thick co...

  18. Electromedical devices test laboratories accreditation

    International Nuclear Information System (INIS)

    Murad, C; Rubio, D; Ponce, S; Alvarez Abri, A; Terron, A; Vicencio, D; Fascioli, E

    2007-01-01

    In the last years, the technology and equipment at hospitals have been increase in a great way as the risks of their implementation. Safety in medical equipment must be considered an important issue to protect patients and their users. For this reason, test and calibrations laboratories must verify the correct performance of this kind of devices under national and international standards. Is an essential mission for laboratories to develop their measurement activities taking into account a quality management system. In this article, we intend to transmit our experience working to achieve an accredited Test Laboratories for medical devices in National technological University

  19. Extraglottic airway devices: technology update

    Directory of Open Access Journals (Sweden)

    Sharma B

    2017-08-01

    Full Text Available Bimla Sharma, Chand Sahai, Jayashree Sood Department of Anaesthesiology, Pain and Perioperative Medicine, Sir Ganga Ram Hospital, New Delhi, India Abstract: Extraglottic airway devices (EADs have revolutionized the field of airway management. The invention of the laryngeal mask airway was a game changer, and since then, there have been several innovations to improve the EADs in design, functionality, safety and construction material. These have ranged from changes in the shape of the mask, number of cuffs and material used, like rubber, polyvinylchloride and latex. Phthalates, which were added to the construction material in order to increase device flexibility, were later omitted when this chemical was found to have serious adverse reproductive outcomes. The various designs brought out by numerous companies manufacturing EADs resulted in the addition of several devices to the airway market. These airway devices were put to use, many of them with inadequate or no evidence base regarding their efficacy and safety. To reduce the possibility of compromising the safety of the patient, the Difficult Airway Society (DAS formed the Airway Device Evaluation Project Team (ADEPT to strengthen the evidence base for airway equipment and vet the new extraglottic devices. A preuse careful analysis of the design and structure may help in better understanding of the functionality of a particular device. In the meantime, the search for the ideal EAD continues. Keywords: extraglottic airway devices, laryngeal mask airway, other extraglottic airway devices, safety, technology update

  20. Efficiency and safety of percuSurge distal protection device in acute ...

    African Journals Online (AJOL)

    user

    2011-04-25

    Apr 25, 2011 ... myocardial infarction. The long-term effects of the distal protection device are still in controversy. The enhanced myocardial efficacy and recovery by aspiration of liberated debris (EMERALD) trial failed to show the effectiveness of the distal protection device in patients with AMI (Yamada and Topol, 2000).

  1. The working of RVNRL pilot plant of Rubber Board and it's safety devices

    International Nuclear Information System (INIS)

    Britto, I.J.; Thomas, E.V.

    1996-01-01

    A pilot plant for producing radiation vulcanized natural rubber latex (RVNRL) was established at Rubber Board, India in 1992. Irradiation is done by a batch process in the plant. The plant has a versatile safety system for safety of operators and people working in and around the plant

  2. 75 FR 38532 - Medical Devices; Availability of Safety and Effectiveness Summaries for Premarket Approval...

    Science.gov (United States)

    2010-07-02

    ... summaries of safety and effectiveness data to the Division of Dockets Management (HFA-305), Food and Drug... Safety and Effectiveness Summaries for Premarket Approval Applications AGENCY: Food and Drug... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket Nos. FDA-2010-M-0068...

  3. 78 FR 50422 - Medical Devices; Availability of Safety and Effectiveness Summaries for Premarket Approval...

    Science.gov (United States)

    2013-08-19

    ... summaries of safety and effectiveness data to the Division of Dockets Management (HFA-305), Food and Drug... of Safety and Effectiveness Summaries for Premarket Approval Applications AGENCY: Food and Drug... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket Nos. FDA-2013-M-0462...

  4. 75 FR 36099 - Medical Devices; Availability of Safety and Effectiveness Summaries for Premarket Approval...

    Science.gov (United States)

    2010-06-24

    ... summaries of safety and effectiveness data to the Division of Dockets Management (HFA-305), Food and Drug...; Availability of Safety and Effectiveness Summaries for Premarket Approval Applications AGENCY: Food and Drug... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket Nos. FDA-2009-M-0317...

  5. Medical devices, electronic health records and assuring patient safety : Future challenges?

    NARCIS (Netherlands)

    Kalkman, Cor J.

    2015-01-01

    The patient safety movement was triggered by publications showing that modern health care is more unsafe than road travel and that more patients are killed annually by avoidable adverse events than by breast cancer [1]. As a result, an urgent need to improve patient safety has dominated

  6. Estimating Safety Effects of Green-Man Countdown Devices at Signalized Pedestrian Crosswalk Based on Cellular Automata

    Directory of Open Access Journals (Sweden)

    Chen Chai

    2017-01-01

    Full Text Available Safety effects of Green-Man Countdown Device (GMCD at signalized pedestrian crosswalks are evaluated. Pedestrian behavior at GMCD and non-GMCD crosswalks is observed and analyzed. A microsimulation model is developed based on field observations to estimate safety performance. Simulation outputs allow analysts to assess the impacts of GMCD at various conditions with different geometric layout, traffic and pedestrian volumes, and the green time. According to simulation results, it is found that the safety impact of GMCD is affected by traffic condition as well as different time duration within green-man signal phase. In general, GMCD increases average walking velocity, especially during the last few seconds. The installation of GMCD improves safety performance generally, especially at more crowded crossings. Conflict severity is increased during last 10 s after GMCD installation. Findings from this study suggest that the current practice, which is to install GMCD at more crowded crosswalks or near the school zone, is effective. Moreover, at crosswalks with GMCD, longer all red signal phase is suggested to improve pedestrian safety during intergreen period.

  7. Renewal of radiological equipment.

    Science.gov (United States)

    2014-10-01

    In this century, medical imaging is at the heart of medical practice. Besides providing fast and accurate diagnosis, advances in radiology equipment offer new and previously non-existing options for treatment guidance with quite low morbidity, resulting in the improvement of health outcomes and quality of life for the patients. Although rapid technological development created new medical imaging modalities and methods, the same progress speed resulted in accelerated technical and functional obsolescence of the same medical imaging equipment, consequently creating a need for renewal. Older equipment has a high risk of failures and breakdowns, which might cause delays in diagnosis and treatment of the patient, and safety problems both for the patient and the medical staff. The European Society of Radiology is promoting the use of up-to-date equipment, especially in the context of the EuroSafe Imaging Campaign, as the use of up-to-date equipment will improve quality and safety in medical imaging. Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or renewal. This plan should look forward a minimum of 5 years, with annual updates. Teaching points • Radiological equipment has a definite life cycle span, resulting in unavoidable breakdown and decrease or loss of image quality which renders equipment useless after a certain time period.• Equipment older than 10 years is no longer state-of-the art equipment and replacement is essential. Operating costs of older equipment will be high when compared with new equipment, and sometimes maintenance will be impossible if no spare parts are available.• Older equipment has a high risk of failure and breakdown, causing delays in diagnosis and treatment of the patient and safety problems both for the patient and the medical staff.• Every healthcare institution or authority should have a plan for medical imaging equipment upgrade or replacement. This plan should look forward a

  8. The risk of a safety-critical event associated with mobile device use in specific driving contexts.

    Science.gov (United States)

    Fitch, Gregory M; Hanowski, Richard J; Guo, Feng

    2015-01-01

    We explored drivers' mobile device use and its associated risk of a safety-critical event (SCE) in specific driving contexts. Our premise was that the SCE risk associated with mobile device use increases when the driving task becomes demanding. Data from naturalistic driving studies involving commercial motor vehicle drivers and light vehicle drivers were partitioned into subsets representative of specific driving contexts. The subsets were generated using data set attributes that included level of service and relation to junction. These attributes were selected based on exogenous factors known to alter driving task demands. The subsets were analyzed using a case-cohort approach, which was selected to complement previous investigations of mobile device SCE risk using naturalistic driving data. Both commercial motor vehicle and light vehicle drivers varied as to how much they conversed on a mobile device but did not vary their engagement in visual-manual subtasks. Furthermore, commercial motor vehicle drivers conversed less frequently as the driving task demands increased, whereas light vehicle drivers did not. The risk of an SCE associated with mobile device use was dependent on the subtask performed and the driving context. Only visual-manual subtasks were associated with an increased SCE risk, whereas conversing was associated with a decreased risk in some driving contexts. Drivers' engagement in mobile device subtasks varies by driving context. The SCE risk associated with mobile device use is dependent on the types of subtasks performed and the driving context. The findings of this exploratory study can be applied to the design of driver-vehicle interfaces that mitigate distraction by preventing visual-manual subtasks while driving.

  9. Toward a treaty on safety and cost-effectiveness of pharmaceuticals and medical devices: enhancing an endangered global public good

    Directory of Open Access Journals (Sweden)

    Faunce Thomas

    2006-03-01

    Full Text Available Abstract • Expert evaluations of the safety, efficacy and cost-effectiveness of pharmaceutical and medical devices, prior to marketing approval or reimbursement listing, collectively represent a globally important public good. The scientific processes involved play a major role in protecting the public from product risks such as unintended or adverse events, sub-standard production and unnecessary burdens on individual and governmental healthcare budgets. • Most States now have an increasing policy interest in this area, though institutional arrangements, particularly in the area of cost-effectiveness analysis of medical devices, are not uniformly advanced and are fragile in the face of opposing multinational industry pressure to recoup investment and maintain profit margins. • This paper examines the possibility, in this context, of States commencing negotiations toward bilateral trade agreement provisions, and ultimately perhaps a multilateral Treaty, on safety, efficacy and cost-effectiveness analysis of pharmaceuticals and medical devices. Such obligations may robustly facilitate a conceptually interlinked, but endangered, global public good, without compromising the capacity of intellectual property laws to facilitate local product innovations.

  10. Safety and protection problems in the management of a plant with cyclotron, radiopharmacy laboratory and PET/CT equipment

    International Nuclear Information System (INIS)

    Russo, A.; Speranza, A.; Panico, M.; Delia, R.; Casale, M.; Salvatore, M.

    2006-01-01

    The importance of Positron Emission Tomography (PET) is spreading and increasing in many clinical diagnostic fields, as well as the oncology, the cardiology, the neurology and so on. A strong input to the diffusion of this imaging technique from the research field to clinical one has been given either by the development of knowledge about PET or the modern technologies, which allow to set up at very suitable prices and in very little volumes, like in an hospital site, complete systems, which consist of: Cyclotron; Radiopharmacy Laboratory; one or more either PET or PET/CT. Such set-up arrangement allows to carry out highly innovative diagnostic examinations with a remarkable achievement of diagnostic quality and large number of daily examinations. In this paper the authors show the achieved know-how with respect to radioprotection for the set-up and running management of two systems such as PET/CT tomography unit, cyclotron and radiopharmacy laboratory, installed one in the Imaging Diagnostic Department of the Hospital of Naples University and used only for medical and research purposes, and the other one in A.C.O.M. (Advanced Center of Oncology in Macerata), used for commercial and research purposes. The following safety problems have been considered: the facility lay-out; the optimisation of the paths either for the operator, or the patients and the radiotracers; the guide lines for the protection and the safety of the patients, operators and general population, in relation to the utilization and the management of either the more common radiotracers (18 F and 11 C) or those in research progress, for example 64 Cu and 124 I; the protocol set up for the image quality control in relation to the patient protection and safety. The above problems have also been considered, taking into account the Italian regulation and the International Recommendations. (authors)

  11. Safety and protection problems in the management of a plant with cyclotron, radiopharmacy laboratory and PET/CT equipment

    Energy Technology Data Exchange (ETDEWEB)

    Russo, A.; Speranza, A.; Panico, M. [University Federico-2, National Research Council - Institute of Biostructures and Bioimaging and Dept. of Bio-morphological and Functional Sciences, Napoli (Italy); Delia, R. [University La Sapienza - sez. Rieti, Faculty of Medicine, Rome (Italy); Casale, M. [University Federico-2, Dept. of Physics - Health Physics School, Napoli (Italy); Salvatore, M. [University Federico-2 and National Research Council - Institute of Biostructures and Bioimaging, Dept. of Bio-morphological and Functional Sciences, Napoli (Italy)

    2006-07-01

    The importance of Positron Emission Tomography (PET) is spreading and increasing in many clinical diagnostic fields, as well as the oncology, the cardiology, the neurology and so on. A strong input to the diffusion of this imaging technique from the research field to clinical one has been given either by the development of knowledge about PET or the modern technologies, which allow to set up at very suitable prices and in very little volumes, like in an hospital site, complete systems, which consist of: Cyclotron; Radiopharmacy Laboratory; one or more either PET or PET/CT. Such set-up arrangement allows to carry out highly innovative diagnostic examinations with a remarkable achievement of diagnostic quality and large number of daily examinations. In this paper the authors show the achieved know-how with respect to radioprotection for the set-up and running management of two systems such as PET/CT tomography unit, cyclotron and radiopharmacy laboratory, installed one in the Imaging Diagnostic Department of the Hospital of Naples University and used only for medical and research purposes, and the other one in A.C.O.M. (Advanced Center of Oncology in Macerata), used for commercial and research purposes. The following safety problems have been considered: the facility lay-out; the optimisation of the paths either for the operator, or the patients and the radiotracers; the guide lines for the protection and the safety of the patients, operators and general population, in relation to the utilization and the management of either the more common radiotracers (18 F and 11 C) or those in research progress, for example 64 Cu and 124 I; the protocol set up for the image quality control in relation to the patient protection and safety. The above problems have also been considered, taking into account the Italian regulation and the International Recommendations. (authors)

  12. Risk Informed Safety Margin Characterization Case Study: Selection of Electrical Equipment To Be Subjected to Environmental Qualification

    Energy Technology Data Exchange (ETDEWEB)

    D. Blanchard; R. Youngblood

    2012-04-01

    In general, the margins-based safety case helps the decision-maker manage plant margins most effectively. It tells the plant decision-maker such things as what margin is present (at the plant level, at the functional level, at the barrier level, at the component level), and where margin is thin or perhaps just degrading. If the plant is safe, it tells the decision-maker why the plant is safe and where margin needs to be maintained, and perhaps where the plant can afford to relax.

  13. FDA Proposes New Safety Measures for Indoor Tanning Devices: The Facts

    Science.gov (United States)

    ... Related Consumer Updates Indoor Tanning: The Risks of Ultraviolet Rays 5 Tips for a Healthy Vacation More in Consumer Updates Animal & Veterinary Children's Health Cosmetics Dietary Supplements Drugs Food Medical Devices Nutrition Radiation-Emitting Products Tobacco Products ...

  14. Analysis of existing work-zone devices with MASH safety performance criteria.

    Science.gov (United States)

    2009-02-01

    Crashworthy, work-zone, portable sign support systems accepted under NCHRP Report No. 350 were analyzed to : predict their safety peformance according to the TL-3 MASH evaluation criteria. An analysis was conducted to determine : which hardware param...

  15. Safety

    International Nuclear Information System (INIS)

    1998-01-01

    A brief account of activities carried out by the Nuclear power plants Jaslovske Bohunice in 1997 is presented. These activities are reported under the headings: (1) Nuclear safety; (2) Industrial and health safety; (3) Radiation safety; and Fire protection

  16. Enhanced-safety underground nuclear power plants based on the use of proven ship-building equipment and technology

    International Nuclear Information System (INIS)

    Pashin, V.M.; Petrov, E.L.; Khazov, B.S.

    1995-01-01

    Investigations performed in the last few years by the State Science Center of the Russian Federation - Academician A. N. Krylov Central Scientific-Research Institute, together with specialized enterprises of the Ministry of Atomic Energy of the Russian Federation, Sudprom, and other agencies of Russia, have shown the promise of marine nuclear power plants for producing underground nuclear power plants with a higher degree of protection from external and internal actions of different intensity. The concept was developed on the basis of an analysis of the energy supply in different regions of Russia and the near-abroad using fossil fuels (lignite, oil, natural gas). The change in the international environment, which makes it possible to convert the military technology, frees the industrial potential and skilled workers in Russia for development of products for the national economy. Stricter international standards and rules for increased safety and protection of nuclear power plants made it necessary to develop a new generation of reactors for ground-based power plants, which under the modern economic conditions cannot be implemented within the time periods acceptable for economics for most of the countries surrounding Russia. In the development of a new generation of ground-based nuclear power plants, the intense improvement of the aviation and space technology must be taken into account. This is connected with the increase in the catastrophes and the threat they present to the safety of unprotected power plants. This article is an abstract of the entire report

  17. Patent foramen ovale closure using a bioabsorbable closure device: safety and efficacy at 6-month follow-up.

    Science.gov (United States)

    Van den Branden, Ben J; Post, Martijn C; Plokker, Herbert W; ten Berg, Jurriën M; Suttorp, Maarten J

    2010-09-01

    The aim of this study was to assess the mid-term safety and efficacy of percutaneous patent foramen ovale (PFO) closure using a bioabsorbable device (BioSTAR, NMT Medical, Boston, Massachusetts). Closure of PFO in patients with cryptogenic stroke has proven to be safe and effective using different types of permanent devices. All consecutive patients who underwent percutaneous PFO closure with the bioabsorbable closure device between November 2007 and January 2009 were included. Residual shunt was assessed using contrast transthoracic echocardiography. Sixty-two patients (55% women, mean age 47.7 ± 11.8 years) underwent PFO closure. The in-hospital complications were a surgical device retrieval in 2 patients (3.2%), device reposition in 1 (1.6%), and a minimal groin hematoma in 6 patients (9.7%). The short-term complications at 1-month follow-up (n = 60) were a transient ischemic attack in the presence of a residual shunt in 1 patient and new supraventricular tachycardia in 7 patients (11.3%). At 6-month follow-up (n = 60), 1 patient without residual shunt developed a transient ischemic attack and 1 developed atrial fibrillation. A mild or moderate residual shunt was noted in 51.7%, 33.9%, and 23.7% after 1-day, 1-month, and 6-month follow-up, respectively. A large shunt was present in 8.3%, 3.4%, and 0% after 1-day, 1-month, and 6-month follow-up. Closure of PFO using the bioabsorbable device is associated with a low complication rate and a low recurrence rate of embolic events. However, a relatively high percentage of mild or moderate residual shunting is still present at 6-month follow-up. Copyright © 2010 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  18. Development of methodologies for optimization of surveillance testing and maintenance of safety related equipment at NPPs. Report of a research coordination meeting. Working material

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-09-01

    This report summarizes the results of the first meeting of the Coordinated Research Programme (CRP) on Development of Methodologies for Optimization of Surveillance Testing and Maintenance of Safety Related Equipment at NPPs, held at the Agency Headquarters in Vienna, from 16 to 20 December 1996. The purpose of this Research Coordination Meeting (RCM) was that all Chief Scientific Investigators of the groups participating in the CRP presented an outline of their proposed research projects. Additionally, the participants discussed the objective, scope, work plan and information channels of the CRP in detail. Based on these presentations and discussions, the entire project plan was updated, completed and included in this report. This report represents a common agreed project work plan for the CRP. Refs, figs, tabs.

  19. Improving the Efficiency of Administrative Decision-Making when Monitoring Reliability and Safety of Oil and Gas Equipment

    Directory of Open Access Journals (Sweden)

    Zemenkova Maria

    2016-01-01

    Full Text Available Methodology of rapid assessment of reliability index was developed based on system analysis of technological parameters. Within functioning of on-line monitoring system of reliability index of industrial facility this method allows to increase efficiency of making managerial decisions on technical and preventive maintenance. The technique is based on the analysis of technological parameters of operational modes of pipeline transport facilities registered by dispatcher controls. The created technique can be used by the operating, research, design institutes and oil and gas transport enterprises when declaring industrial safety. The received mathematical models allow federal services of supervision, the independent expert organizations to predict the development of reliability in the registered block of dispatching data either in real time mode, or taking into account the dynamics of service conditions of the object.

  20. Safety evaluation report on Westinghouse Electric Company ECCS evaluation model for plants equipped with upper head injection

    International Nuclear Information System (INIS)

    Lauben, G.N.; Wagner, N.H.; Israel, S.L.; McPherson, G.D.; Hodges, M.W.

    1978-04-01

    For plants which include an ice condenser containment concept, Westinghouse has planned an additional safety system known as the upper head injection (UHI) system to augment the emergency core cooling system. This system is comprised of additional accumulator tanks and piping arranged to supply cooling water to the top of the core during the blowdown period following a postulated large-break loss-of-coolant accident (LOCA). The objective of UHI is to add to the core cooling provided by the conventional emergency core cooling system (ECCS) and so permit operation at linear heat rates comparable to those permitted in plants utilizing the dry containment concept. In this way, plants which include the UHI system would have greater operating flexibility while still meeting the acceptance criteria as defined in paragraph 50.46 of 10 CFR Part 50. This review is concerned with those changes to the Westinghouse ECCS evaluation model that have been proposed for the UHI-LOCA model

  1. Regulations No. 59 of 20 February 1978 on X-ray skin therapy equipment up to 50 kV

    International Nuclear Information System (INIS)

    1978-01-01

    These regulations lay down the provisions to be complied with for the protection of medical staff and patients when using X-ray equipment for skin therapy. The operators of such equipment must comply with the technical guidelines contained in the regulations and provision is made for annual inspections to ensure that the devices meet the necessary safety standards. (NEA) [fr

  2. Augmented reality for improved safety

    CERN Multimedia

    Stefania Pandolfi

    2016-01-01

    Sometimes, CERN experts have to operate in low visibility conditions or in the presence of possible hazards. Minimising the duration of the operation and reducing the risk of errors is therefore crucial to ensuring the safety of personnel. The EDUSAFE project integrates different technologies to create a wearable personnel safety system based on augmented reality.    The EDUSAFE integrated safety system uses a camera mounted on the helmet to monitor the working area.  In its everyday operation of machines and facilities, CERN adopts a whole set of measures and safety equipment to ensure the safety of its personnel, including personal wearable safety devices and access control systems. However, sometimes, scheduled and emergency maintenance work needs to be done in zones with potential cryogenic hazards, in the presence of radioactive equipment or simply in demanding conditions where visibility is low and moving around is difficult. The EDUSAFE Marie Curie Innovative&...

  3. 78 FR 25916 - Authorization of Radiofrequency Equipment

    Science.gov (United States)

    2013-05-03

    ...] Authorization of Radiofrequency Equipment AGENCY: Federal Communications Commission. ACTION: Proposed rule... bodies, and measurement procedures used to determine RF equipment compliance. The Commission believes... Commission is responsible for an equipment authorization program for radiofrequency (RF) devices under part 2...

  4. A novel safety device with metal counter meshing gears discriminator directly driven by axial flux permanent magnet micromotors based on MEMS technology

    Science.gov (United States)

    Zhang, Weiping; Chen, Wenyuan; Zhao, Xiaolin; Li, Shengyong; Jiang, Yong

    2005-08-01

    In a novel safety device based on MEMS technology for high consequence systems, the discriminator consists of two groups of metal counter meshing gears and two pawl/ratchet wheel mechanisms. Each group of counter meshing gears is onepiece and driven directly by an axial flux permanent magnet micromotor respectively. The energy-coupling element is an optical shutter with two collimators and a coupler wheel. The safety device's probability is less than 1/106. It is fabricated by combination of an LiGA-like process and precision mechanical engineering. The device has simple structure, few dynamic problems, high strength and strong reliability.

  5. Safety-related control air systems

    International Nuclear Information System (INIS)

    Anon.

    1977-01-01

    This Standard applies to those portions of the control air system that furnish air required to support, control, or operate systems or portions of systems that are safety related in nuclear power plants. This Standard relates only to the air supply system(s) for safety-related air operated devices and does not apply to the safety-related air operated device or to air operated actuators for such devices. The objectives of this Standard are to provide (1) minimum system design requirements for equipment, piping, instruments, controls, and wiring that constitute the air supply system; and (2) the system and component testing and maintenance requirements

  6. 76 FR 47210 - Medical Devices; Availability of Safety and Effectiveness Summaries for Premarket Approval...

    Science.gov (United States)

    2011-08-04

    ... placed on the Internet. Section 10.33(b) provides that FDA may, for good cause, extend this 30-day period.......... Chestnut Medical Pipeline embolization device.... April 6, 2011. Technologies, Inc. P100034 FDA-2011-M-0295... Scientific Corp ION paclitaxel-eluting coronary April 22, 2011. stent system (monorail and over- the-wire...

  7. 78 FR 950 - Medical Devices; Availability of Safety and Effectiveness Summaries for Premarket Approval...

    Science.gov (United States)

    2013-01-07

    ..., FDA- 2012-M-0965, FDA-2012-M-0968, FDA-2012-M-1011, and FDA-2012-M-1013] Medical Devices; Availability.... Glucose Monitoring System (TGMS). P000008/S017, FDA-2012-M-1013.. Allergan, Inc..... LAP-BAND \\TM\\ February 16, 2011. Adjustable Gastric Banding System. P100049, FDA-2012-M-0893....... Torax Medical, Inc...

  8. Analysis of solutions for passively activated safety shutdown devices for SFR

    International Nuclear Information System (INIS)

    Burgazzi, Luciano

    2013-01-01

    Highlights: • Innovative systems for emergency shut down of fast reactors are proposed. • The concepts of inherent and passive safety are put forward. • The relative analysis in terms of safety and reliability is presented. • A comparative assessment among the concepts is performed. • Path forward is tracked. -- Abstract: In order to enhance the inherent safety of fast reactors, innovative reactivity control systems have been proposed for intrinsic ultimate shut-down instead of conventional scram rods, to cope with the potential consequences of severe unprotected transient accidents, such as an energetic core disruptive accident, as in case of sodium fast reactors. The passive shut-down systems are designed to shut-down system only by inherent passive reactivity feedback mechanism, under unprotected accident conditions, implying failure of reactor protection system. They are conceived to be self-actuated without any signal elaboration, since the actuation of the system is triggered by the effects induced by the transient like material dilatation, in case of overheating of the coolant for instance, according to fast reactor design to meet the safety requirements. This article looks at different special shutdown systems specifically engineered for prevention of severe accidents, to be implemented on fast reactors, with main focus on the investigation of the performance of the self-actuated shutdown systems in sodium fast reactors

  9. 75 FR 11624 - Highway Safety Programs; Conforming Products List of Evidential Breath Alcohol Measurement Devices

    Science.gov (United States)

    2010-03-11

    ... X PBA 3000[dash]P X X PBA 3000C X X Alcohol Data Sensor X X Phoenix X X Phoenix 6.0 X X EV 30 X X FC...-0016] Highway Safety Programs; Conforming Products List of Evidential Breath Alcohol Measurement... 71480) for instruments that conform to the Model Specifications for Evidential Breath Alcohol...

  10. Modified enforcement policy relating to 10 CFR 50.49, ''Environmental qualification of electrical equipment important to safety for nuclear power plants'' (Generic Letter 88-07)

    International Nuclear Information System (INIS)

    Miraglia, F.J.

    1992-01-01

    Generic Letters, Bulletins, and Information Notices have been issued to provide guidance regarding the application and enforcement of 10 CFR 50.49, ''Environmental Qualification of Electric Equipment Important to Safety for Nuclear Power Plants.'' Generic Letter 85-15, issued August 6, 1985, and Generic Letter 86-15, issued September 22, 1986, provided information related to the deadlines for compliance with 10 CFR 50.49 and possible civil penalties applicable to licensees who were not in compliance with the rule as of the November 30, 1985 deadline. Upon review, the Commission found that the EQ Enforcement Policy promulgated in Generic Letter 86-15, could result in imposition of civil penalties that did not properly reflect the safety significance of EQ violations with respect to civil penalties imposed in the past. In the interest of continuing a tough but fair enforcement policy, the Commission determined that the EQ Enforcement Policy should be revised. The purpose of this letter is to provide a modification to the NRC's enforcement policy, as approved by the Commission, for environmental qualification (EQ) violations. This letter replaces the guidance provided in Generic Letters 85-15 and 86-15

  11. Establishment of experimental equipments in irradiation technology development building (2)

    International Nuclear Information System (INIS)

    Shibata, Hiroshi; Nakano, Hiroko; Suzuki, Yoshitaka; Ohtsuka, Noriaki; Nishikata, Kaori; Takeuchi, Tomoaki; Hirota, Noriaki; Tsuchiya, Kunihiko

    2018-01-01

    From the viewpoints of utilization improvement of the Japan Materials Testing Reactor (JMTR), the experimental devices have been established for the out-pile tests in the irradiation technology development building. The devices for the irradiation capsule assembly, material tests and inspections were established at first and experimental data were accumulated before the neutron irradiation tests. On the other hand, after the Great East Japan Earthquake, the repairs and earthquake-resistant measures of the existing devices were carried out. New devices and equipments were also established for the R and D program for power plant safety enhancement of the Agency for Natural Resources and Energy, Ministry of Economy, Trade and Industry (METI) and 99 Mo/ 99m Tc production development under the Tsukuba International Strategic Zone. This report describes the outline and basic operation manuals of the devices established from 2011 to 2016 and the management points for the safety works in the irradiation technology development building. (author)

  12. Comparison of the efficacy and safety of thrombectomy devices in acute stroke : a network meta-analysis of randomized trials.

    Science.gov (United States)

    Saber, Hamidreza; Rajah, Gary B; Kherallah, Riyad Y; Jadhav, Ashutosh P; Narayanan, Sandra

    2017-12-15

    Mechanical thrombectomy (MT) is increasingly used for large-vessel occlusions (LVO), but randomized clinical trial (RCT) level data with regard to differences in clinical outcomes of MT devices are limited. We conducted a network meta-analysis (NMA) that enables comparison of modern MT devices (Trevo, Solitaire, Aspiration) and strategies (stent retriever vs aspiration) across trials. Relevant RCTs were identified by a systematic review. The efficacy outcome was 90-day functional independence (modified Rankin Scale (mRS) score 0-2). Safety outcomes were 90-day catastrophic outcome (mRS 5-6) and symptomatic intracranial hemorrhage (sICH). Fixed-effect Bayesian NMA was performed to calculate risk estimates and the rank probabilities. In a NMA of six relevant RCTs (SWIFT, TREVO2, EXTEND-IA, SWIFT-PRIME, REVASCAT, THERAPY; total of 871 patients, 472 Solitaire vs medical-only, 108 Aspiration vs medical-only, 178 Trevo vs Merci, and 113 Solitaire vs Merci) with medical-only arm as the reference, Trevo had the greatest functional independence (OR 4.14, 95% credible interval (CrI) 1.41-11.80; top rank probability 92%) followed by Solitaire (OR 2.55, 95% CrI 1.75-3.74; top rank probability 72%). Solitaire and Aspiration devices had the greatest top rank probability with respect to low sICH and catastrophic outcomes (76% and 91%, respectively), but without significant differences between each other. In a separate network of seven RCTs (MR-CLEAN, ESCAPE, EXTEND-IA, SWIFT-PRIME, REVASCAT, THERAPY, ASTER; 1737 patients), first-line stent retriever was associated with a higher top rank probability of functional independence than aspiration (95% vs 54%), with comparable safety outcomes. These findings suggest that Trevo and Solitaire devices are associated with a greater likelihood of functional independence whereas Solitaire and Aspiration devices appear to be safer. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights

  13. Safety and efficacy of cervical laminoplasty using a piezosurgery device compared with a high-speed drill.

    Science.gov (United States)

    Li, Kunpeng; Zhang, Wen; Li, Bin; Xu, Hui; Li, Zhong; Luo, Dawei; Zhang, Jingtao; Ma, Jinzhu

    2016-09-01

    Piezosurgery is a relatively new osteotomy technique using microvibrations of scalpels at ultrasonic frequencies to perform safe and effective osteotomies without damage to adjacent soft tissue, which is widely used in spinal, oral, and maxillofacial surgery. We hypothesized that such a device could also be useful in cervical laminoplasty. The purpose of this study was to compare the safety and efficacy of a piezosurgery device with those of a highspeed drill in cervical laminoplasty. A prospectively randomized clinical study was designed. Forty-two consecutive patients were enrolled in the study. All patients underwent modified expansive open-door laminoplasty and were randomly divided into 2 groups according to the instrument for transection of the lamina, using high-speed drill (drill group) or piezosurgery device (piezosurgery group). The operation time, intraoperative blood loss, and postoperative drainage were recorded. Japanese Orthopedic Association (JOA) score and visual analogue scale (VAS) as clinical assessments were quantified. No significant difference was observed in the operation time between the 2 groups. In the piezosurgery group, there were less loss of the intraoperative blood and postoperative drainage compared with the drill group. However, clinical results (VAS and JOA scores) showed no significant difference between both groups during the all follow-up periods. The piezosurgery is a useful instrument and at least as safe and efficacious as the conventional high-speed drill in cervical laminoplasty.

  14. Neutronic, thermal-hydraulics and safety calculations of a Miniplate Irradiation Device (MID) of dispersion type fuel elements

    International Nuclear Information System (INIS)

    Domingos, Douglas Borges

    2010-01-01

    Neutronic, thermal-hydraulics and accident analysis calculations were developed to estimate the safety of a Miniplate Irradiation Device (MID) to be placed in the IEA-R1 reactor core. The irradiation device is used to receive miniplates of U 3 O 8 -Al and U 3 Si 2 - Al dispersion fuels, LEU type (19.75 % 235 U) with uranium densities of, respectively, 3.2 gU/cm 3 and 4.8 gU/cm 3 . The fuel miniplates will be irradiated to nominal 235 U burnup levels of 50% and 80%, in order to qualify the above high-density dispersion fuels to be used in the Brazilian Multipurpose Reactor (RMB), now in the conception phase. For the neutronic calculation, the computer codes CITATION and 2DB were utilized. The computer code FLOW was used to calculate the coolant flow rate in the irradiation device, allowing the determination of the fuel miniplate temperatures with the computer model MTRCR-IEA-R1. A postulated Loss of Coolant Accident (LOCA) was analyzed with the computer codes LOSS and TEMPLOCA, allowing the calculation of the fuel miniplate temperatures after the reactor pool draining. The calculations showed that the irradiation should occur without adverse consequences in the IEA-R1 reactor. (author)

  15. The Development of Computer Code for Safety Injection Tank (SIT) with Fluidic Device(FD) Blowdown Test

    International Nuclear Information System (INIS)

    Lee, Joo Hee; Kim, Tae Han; Choi, Hae Yun; Lee, Kwang Won; Chung, Chang Kyu

    2007-01-01

    Safety Injection Tanks (SITs) with the Fluidic Device (FD) of APR1400 provides a means of rapid reflooding of the core following a large break Loss Of Coolant Accident (LOCA), and keeping it covered until flow from the Safety Injection Pump (SIP) becomes available. A passive FD can provide two operation stages of a safety water injection into the RCS and allow more effective use of borated water in case of LOCA. Once a large break LOCA occurs, the system will deliver a high flow rate of cooling water for a certain period of time, and thereafter, the flow rate is reduced to a lower flow rate. The conventional computer code 'TURTLE' used to simulate the blowdown of OPR1000 SIT can not be directly applied to simulate a blowdown process of the SIT with FD. A new computer code is needed to be developed for the blowdown test evaluation of the APR1400 SIT with FD. Korea Power Engineering Company (KOPEC) has developed a new computer code to analyze the characteristics of the SIT with FD and validated the code through the comparison of the calculation results with the test results obtained by Ulchin 5 and 6 units pre-operational test and VAlve Performance Evaluation Rig (VAPER) tests performed by The Korea Atomic Energy Research Institute (KAERI)

  16. Plant control device

    International Nuclear Information System (INIS)

    Sato, Masuo; Ono, Makoto.

    1995-01-01

    A plant control device comprises an intellectual instrumentation group for measuring a predetermined process amount, an intellectual equipment group operating in accordance with a self-countermeasure, a system information space for outputting system information, a system level monitoring and diagnosing information generalization section for outputting system information, a system level maintenance information generalization section for outputting information concerning maintenance, a plant level information space and a plant level information generalization section. Each of them determines a state of the plant autonomously, and when abnormality is detected, each of the intellectual instrumentation, equipments and systems exchange information with each other, to conduct required operations including operations of intellectual robots, as required. Appropriate countermeasures for gauges, equipments and systems can be conducted autonomously at a place where operators can not access to improve reliability of complicate operations in the working site, as well as improve plant safety and reliability. (N.H.)

  17. Simulation experiments concerning functioning tests of technical safety devices with process computers. Pt. 2

    International Nuclear Information System (INIS)

    Hawickhorst, W.

    1976-12-01

    Computerized inspection techniques of engineered safety systems improve the diagnosis capability, relative to the presently used techniques, even if anticipated system disturbances can only be qualitatively predicted. To achieve this, the system to be inspected must be partitioned into small subsystems, which can be treated independently from each other. This report contains the formulation of a standardized inspection concept based on system decomposition. Its performance is discussed by means of simulation experiments. (orig.) [de

  18. Evaluation on thermal-hydraulic characteristics for passive safety device of APR1400

    Energy Technology Data Exchange (ETDEWEB)

    Yoo, Seong Yeon; Lee, S. H.; Son, M. K. [Korea Association for Nuclear Technology, Taejon (Korea, Republic of); Jee, M. S.; Chung, M. H. [Chungnam National Univ., Taejon (Korea, Republic of)

    2001-07-15

    To establish evaluation and verification guideline for the APR1400, thermal-hydraulic characteristics for fuel rod bundle, reactor vessel and fluidic device is analyzed using FLUENT. Scope and major results of research are as follows : Thermal-hydraulic characteristics for nuclear fuel rod bundle: design data for nuclear fuel rod bundle and structure are surveyed, and 3 x 3 sub-channel model is adopted to investigate the fluid flow and heat transfer characteristics in fuel rod bundle. Computational results are compared with the heat transfer data measured by naphthalene sublimation method, and numerical analysis and evaluation are performed at various design conditions and flow conditions. Thermal-hydraulic characteristics for reactor vessel: reactor vessel design data are surveyed to develop numerical model. Porous media model is applied for fuel rod bundle, and full-scale, three dimensional simulation is performed at actual operating conditions. Distributions of velocity, pressure and temperature are discussed. Flow characteristics for fluidic device: three dimensional numerical model for fluidic device is developed, and numerical results are compared with experimental data obtained at KAERI in order to verify numerical simulation. In addition, variation of flow rate is investigated at various elapsed times after valve operating, and flow characteristics is analyzed at low and high flow rate conditions, respectively.

  19. Efficacy and Safety of REVIVE SE Thrombectomy Device for Acute Ischemic Stroke: River JAPAN (Reperfuse Ischemic Vessels with Endovascular Recanalization Device in Japan).

    Science.gov (United States)

    Sakai, Nobuyuki; Ota, Shinzo; Matsumoto, Yasushi; Kondo, Rei; Satow, Tetsu; Kubo, Michiya; Tsumoto, Tomoyuki; Enomoto, Yukiko; Kataoka, Taketo; Imamura, Hirotoshi; Todo, Kenichi; Hayakawa, Mikito; Yamagami, Hiroshi; Toyoda, Kazunori; Ito, Yasushi; Sugiu, Kenji; Matsumaru, Yuji; Yoshimura, Shinichi

    2018-04-15

    REVIVE SE (REVIVE) is a closed-ended, self-expanding stent retriever used in the RIVER JAPAN study. We present our early experience with REVIVE for revascularization of acute ischemic stroke (AIS) in patients who have failed or are ineligible for intravenous recombinant tissue plasminogen activator treatment. This prospective, single-arm, non-randomized, multicenter registry study followed up patients undergoing mechanical thrombectomy with REVIVE for 90 days. The primary endpoint was a post-procedure Thrombolysis in Cerebral Infarction (TICI) score ≥2a. Secondary endpoints were clot migration/embolization; recanalization without symptomatic intracranial hemorrhage (ICH) at 24 h; symptomatic ICH; good neurological outcome (modified Rankin Scale score ≤2 National Institute of Health Stroke Scale (NIHSS) score decrease ≥10) at day 90; device- or procedure-related serious adverse events (SAEs) and mortality at day 90. To confirm non-inferiority of REVIVE, results were compared with historical data of the Merci Retriever. About 49 patients were enrolled (median age 73 years; males 46.9%; middle cerebral artery (MCA) occlusion 83.7%; median NIHSS score 17). A post-procedure TICI score ≥2a was observed in 73.5% (36/49, 95% confidence interval [CI] 58.9-85.1) of patients. No post-procedural clot migration/embolization events occurred. Successful recanalization without symptomatic ICH was observed in 62.5% (30/48, 95% CI 47.4-76.0). The good neurological outcome was achieved in 66.7% (32/48) patients. Symptomatic ICH and device- or procedure-related SAEs were reported in 6.3% and 12.2% of patients, respectively. Two deaths were reported. REVIVE demonstrated equivalent efficacy and safety as the Merci Retriever. Results suggest that REVIVE is effective and safe in recanalizing occluded intracranial arteries in AIS.

  20. Analysis of the network protection devices action connected with the Krsko NPP operation safety

    International Nuclear Information System (INIS)

    Omahen, P.; Struc, S.

    1995-01-01

    The example of failure that took place in Zagreb on 30 March, 1995, has been investigated in order to obtain appropriate answers to the unexpected electric power system (ESP) response and consecutive outage of the Krsko nuclear power plant (NPP). The analysis has been made of particular operating and stability conditions, related to the functioning of distance relays line protection. Using a consequent simulation model of the EPS (European interconnection) under specified fault condition, the research of EPS operation (relays action) and stability has been done. The appropriate simulation results have been compared to the available measured data which had been collected by the SOREL on-line data acquisition system. In the end, a practise proposal for measures to be taken with the target of achieving the foreseen and expected operation of the EPS equipment that effects operation of the Krsko NPP is given. (author)

  1. Normas básicas de seguridad durante el manejo de equipos de radiaciones no ionizantes Safety basic rules when handling non-ionizing radiation equipment

    Directory of Open Access Journals (Sweden)

    Rosa María Armida Bretones

    2012-03-01

    this Prevention Department in cooperation with The Medical Physics Department a procedure based on basic preventive criteria has been elaborated to guarantee health and safety of the employees who handle non-ionizing radiation emitting equipment in our hospital and specialized centers. To draw the procedure: scientific literature related to the electromagnetic fields effects over health has been checked, periodical working meetings have been held between both above mentioned departments; non-ionizing radiation equipment have been identified as well as the places they are based or used; and expert people advice has been used. The procedure sets control and follow-up measurements both for people and equipment such as follows: Shortwave, microwave and magnetic therapy, Nuclear magnetic resonance, Laser, Ultraviolet radiation. The procedure and illustrative posters have been deployed to the linked departments, the information and training having been given to the employees who work with kind of equipment.

  2. The role of man in ensuring the safety of nuclear devices

    International Nuclear Information System (INIS)

    Bilek, M.

    1983-01-01

    The impact of the human factor on the safety and reliability of nuclear power plant operation is discussed and its critical aspects are pointed out: shortcomings in the design of the control room, in the organization and control of the plant and in regulations and working procedures and errors in the training of operators. The question is discussed of the operator's behavior during predicted and unpredicted failure of the system and his ability to recieve and process information. Securing the safe and reliable operation of nuclear power plants can substantially influence the current attitude of the public to their construction. (J.B.)

  3. SAFETY

    CERN Multimedia

    Niels Dupont

    2013-01-01

    CERN Safety rules and Radiation Protection at CMS The CERN Safety rules are defined by the Occupational Health & Safety and Environmental Protection Unit (HSE Unit), CERN’s institutional authority and central Safety organ attached to the Director General. In particular the Radiation Protection group (DGS-RP1) ensures that personnel on the CERN sites and the public are protected from potentially harmful effects of ionising radiation linked to CERN activities. The RP Group fulfils its mandate in collaboration with the CERN departments owning or operating sources of ionising radiation and having the responsibility for Radiation Safety of these sources. The specific responsibilities concerning "Radiation Safety" and "Radiation Protection" are delegated as follows: Radiation Safety is the responsibility of every CERN Department owning radiation sources or using radiation sources put at its disposition. These Departments are in charge of implementing the requi...

  4. Elimination of nuclear device in tunnel 108K. Safety of works and ecological cleanness

    International Nuclear Information System (INIS)

    Andrusenko, B. A.; Kuznetsov, Yu. I.; Litvinov, B. V.; Nechai, V. Z.; Smirnov, V. Z.; Zherbina, A.N.; Kozlov, E. P.; Matuschenko, A. M.; Zhantikin, T. M.; Smagulov, S. G.; Tukhvatulin, Sh. T.

    1997-01-01

    This paper represents the Russian and Kazakhstan specialists activity on ND elimination located in tunnel 108K at the former Semipalatinsk test site. The completed works system which is a great realized ecologically clean project for the interests of the solution of ecological problems and environment protection at the Semipalatinsk test site, is considered successively in this paper. The special attention is paid to the measures the application of which allowed to provide the absolute observance of ecological cleanness and operation safety - expertise of radiation and ecological project safety, joint radio-ecological control before and after the ND elimination, procedures of the end ND box opening, visualization and decision on the ND state, and the coordinated physical measuring as well confirming the fact of the charge BB acting and ND elimination. The paper gives the detailed comments on the realized project decisions for the stemming complex erection the use of which provided the safe disposal and sealing of chemical BB explosion products and atomized fission materials in the end box and allowed to prevent their release into the day surface. While erecting the stemming complex the new materials of stemming and stemming work technology of principle were used. The basic experiments outcomes and argumentation of the obtained experience use during the joint work while preparing and realizing the further International Agreements on the former Semipalatinsk test site, are presented in the paper conclusion

  5. Process and device for controlling the operatability of a measuring channel in safety arrangements

    International Nuclear Information System (INIS)

    Edelmann, M.

    1983-01-01

    In addition to the neutron - and temperature - measuring channels, the detectors and thermocouples for active functional testing are also included in the safety circuits. The measuring parameter (neutron flux or coolant outlet temperature) is modulated by the output control system or output and/or coolant flow. This modulation is determined using an auxillary parameter (movement of control rods or neutron flux). To represent the actual value of the measuring parameter to be compared with the previously determined reference value, there is a division of the relative change of the neutron flux or the coolant outlet temperature by the change of control rod position or reactor output caused by it. The effect of the auxiliary parameter on the measured parameter is measured by the cross correlation of both of them and of the auxiliary parameter directly or by auto correlation. The coarse and fine monitoring of the measuring channels takes place with different time constants. (orig./PW)

  6. Safety

    International Nuclear Information System (INIS)

    2001-01-01

    This annual report of the Senior Inspector for the Nuclear Safety, analyses the nuclear safety at EDF for the year 1999 and proposes twelve subjects of consideration to progress. Five technical documents are also provided and discussed concerning the nuclear power plants maintenance and safety (thermal fatigue, vibration fatigue, assisted control and instrumentation of the N4 bearing, 1300 MW reactors containment and time of life of power plants). (A.L.B.)

  7. "We can't get along without each other": Qualitative interviews with physicians about device industry representatives, conflict of interest and patient safety.

    Directory of Open Access Journals (Sweden)

    Anna R Gagliardi

    Full Text Available Physician relationships with device industry representatives have not been previously assessed. This study explored interactions with device industry representatives among physicians who use implantable cardiovascular and orthopedic devices to identify whether conflict of interest (COI is a concern and how it is managed.A descriptive qualitative approach was used. Physicians who implant orthopedic and cardiovascular devices were identified in publicly available directories and web sites, and interviewed about their relationships with device industry representatives. Sampling was concurrent with data collection and analysis. Data were analyzed and discussed using constant comparative technique by all members of the research team.Twenty-two physicians (10 cardiovascular, 12 orthopedic were interviewed. Ten distinct representative roles were identified: purchasing, training, trouble-shooting, supplying devices, assisting with device assembly and insertion, supporting operating room staff, mitigating liability, conveying information about recalls, and providing direct and indirect financial support. Participants recognized the potential for COI but representatives were present for the majority of implantations. Participants revealed a tension between physicians and representatives that was characterized as "symbiotic", but required physicians to be vigilant about COI and patient safety, particularly because representatives varied regarding disclosure of device defects. They described a concurrent tension between hospitals, whose policies and business practices were focused on cost-control, and physicians who were required to comply with those policies and use particular devices despite concerns about their safety and effectiveness.Given the potential for COI and threats to patient safety, further research is needed to establish the clinical implications of the role of, and relationship with device industry representatives; and whether and how

  8. Guidelines on the safety of light-based home-use hair removal devices from the European Society for Laser Dermatology

    DEFF Research Database (Denmark)

    Town, Graham; Ash, C; Dierickx, C

    2012-01-01

    . These guidelines provide a definition of light-based home-use technology, to inform healthcare professionals about home-use light-based technology and encourage manufacturers wishing to sell in Europe to adopt 'best practice'. The review presents the current status on standards and regulation issues and considers...... home-use safety issues, encompassing human, device and electrical safety, given risks to the eyes and skin from optical radiation both to the consumer and persons in the vicinity. Proposed technical measurement methodology is considered with focus on recognized critical parameters for the safe use...... of light-based hair removal technology including recording the technical performance and safety claims of a range of home-use hair removal devices. The literature review emphasizes potential adverse incidents and safety aspects of treating cosmetic conditions, such as unwanted hair growth. Although some...

  9. Eat-by-light fiber-optic and micro-optic devices for food quality and safety assessment

    Science.gov (United States)

    Mignani, A. G.; Ciaccheri, L.; Cucci, C.; Mencaglia, A. A.; Cimato, A.; Attilio, C.; Thienpont, H.; Ottevaere, H.; Paolesse, R.; Mastroianni, M.; Monti, D.; Buonocore, G.; Del Nobile, A.; Mentana, A.; Grimaldi, M. F.; Dall'Asta, C.; Faccini, A.; Galaverna, G.; Dossena, A.

    2007-06-01

    A selection is presented of fiber-optic and micro-optic devices that have been designed and tested for guaranteeing the quality and safety of typical foods, such as extra virgin olive oil, beer, and milk. Scattered colorimetry is used to authenticate various types of extra virgin olive oil and beer, while a fiber-optic-based device for UV-VIS-NIR absorption spectroscopy is exploited in order to obtain the hyperspectral optical signature of olive oil. This is done not only for authentication purposes, but also so as to correlate the spectral data with the content of fatty acids, which are important nutritional factors. A micro-optic sensor for the detection of olive oil aroma that is capable of distinguishing different ageing levels of extra virgin olive oil is also presented. It shows effective potential for acting as a smart cap of bottled olive oil in order to achieve a non-destructive olfactory perception of oil ageing. Lastly, a compact portable fluorometer for the rapid monitoring of the carcinogenic M1 aflatoxin in milk, is experimented.

  10. Eat-by-light: fiber-optic and micro-optic devices for food safety and quality assessment

    Science.gov (United States)

    Mignani, A. G.; Ciaccheri, L.; Cucci, C.; Mencaglia, A. A.; Cimato, A.; Attilio, C.; Thienpont, H.; Ottevaere, H.; Paolesse, R.; Mastroianni, M.; Monti, D.; Buonocore, G.; Del Nobile, A.; Mentana, A.; Dall'Asta, C.; Faccini, A.; Galaverna, G.; Dossena, A.

    2007-07-01

    A selection of fiber-optic and micro-optic devices is presented designed and tested for monitoring the quality and safety of typical foods, namely the extra virgin olive oil, the beer, and the milk. Scattered colorimetry is used for the authentication of various types of extra virgin olive oil and beer, while a fiber-optic-based device for UV-VIS-NIR absorption spectroscopy is exploited in order to obtain the hyperspectral optical signature of olive oil. This is done not only for authentication purposes, but also so as to correlate the spectral data with the content of fatty acids that are important nutritional factors. A micro-optic sensor for the detection of olive oil aroma is presented. It is capable of distinguishing different ageing levels of extra virgin olive oil. It shows effective potential for acting as a smart cap of bottled olive oil in order to achieve a non-destructive olfactory perception of oil ageing. Lastly, a compact portable fluorometer is experimented for the rapid monitoring of the carcinogenic M1 aflatoxin in milk.

  11. Proximal Occlusion of Medium-Sized Vessels with the Penumbra Occlusion Device: A Study of Safety and Efficacy

    Energy Technology Data Exchange (ETDEWEB)

    Jambon, E.; Petitpierre, F. [Pellegrin Hospital, Department of Radiology (France); Brizzi, V.; Dubuisson, V. [Pellegrin Hospital, Department of Surgery (France); Bras, Y. Le; Grenier, N.; Cornelis, F., E-mail: cornelisfrancois@gmail.com [Pellegrin Hospital, Department of Radiology (France)

    2017-02-15

    PurposeTo retrospectively investigate the safety and efficacy of hybrid proximal coiling of various medium-sized vessels (4 to 8 mm) using the Penumbra Occlusion Device (POD).Materials and MethodsFrom October 2014 to February 2016, 37 proximal embolizations were performed with PODs in 36 patients (mean age: 50.8, range: 10–86; 29 male, 7 female). Vessel occlusions were achieved under fluoroscopic guidance using a 2.7 French microcatheter. Among the 36 vessels targeted, 16 were splenic arteries, 11 renal arteries, 4 mesenteric arteries, 3 arteriovenous fistulae, 1 iliac artery, and 1 gonadal vein. Intermittent follow-up angiography was performed to assess the flow for final occlusion. Outcomes and complications were assessed by clinical and/or imaging follow-up.ResultsTo produce proximal occlusion of the intended vessels, the POD was used alone in 19 embolizations (51.4 %). In 12 procedures (32.4 %), POD was used as a coil constrainer to secure the coil construct. In 6 procedures (16.2 %), additional embolic devices were used to achieve vessel occlusion after initial POD deployment. After a mean follow-up of 3.2 months, no POD migration was observed but two complications occurred (5.4 %): one post embolic syndrome and one extensive infarction with splenic abscess.ConclusionThe POD system allows safe and effective proximal embolization of medium-sized vessels in a variety of clinical settings.

  12. Safety, efficacy, and usage compliance of home-use device utilizing RF and light energies for treating periorbital wrinkles.

    Science.gov (United States)

    Gold, Michael H; Biron, Julie; Levi, Liora; Sensing, Whitney

    2017-03-01

    The aging process is often associated with undesirable effects on facial skin such as skin redundancy, reduction of elasticity, and increased wrinkling. Radiofrequency (RF) and light-emitting diodes (LEDs) are widely used, clinically proven technologies for skin rejuvenation. This study aimed to evaluate the safety, efficacy, and usage compliance of the home-use device, utilizing RF and LED energies, for self-treatment of periorbital wrinkles and improvement of skin appearance. Thirty-three subjects performed 21 treatment sessions every other day, over 6 weeks on the periorbital areas. In addition, two maintenance treatments were conducted 1 and 2 months following treatment end. Each subject served as his/her own control, comparing results before treatment, and 3 months following treatment end. Thirty subjects completed the study. A blinded, independent photographs assessment of three dermatologists demonstrated an average reduction of 1.49 Fitzpatrick scores (P Skin Tightening (HST) device offers a safe and effective in-home noninvasive technique to improve the appearance of age-related periorbital wrinkles. © 2016 Wiley Periodicals, Inc.

  13. 21 CFR 866.4830 - Rocket immunoelectro-phoresis equipment.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES IMMUNOLOGY AND MICROBIOLOGY DEVICES Immunology Laboratory Equipment and Reagents... equipment for clinical use is a device used to perform a specific test on proteins by using a procedure...

  14. The effect of safety education based on Health Belief Model (HBM on the workers practice of Borujen industrial town in using the personal protection respiratory equipments

    Directory of Open Access Journals (Sweden)

    A. Hasanzadeh

    2008-04-01

    Full Text Available Background and aims   Every year 50-158 million occupational diseases and job accidents occur in the world. Studies on the job injuries show that about 150000 injuries occur annually in  Iran. Unhealthy behaviors are important problems in public health. Education is one of the best ways to change unhealthy behaviors. Interventions based on model and theories have many  capacities for behavior change. Health Belief Model is one of the health education models that are  useful for behavior change. This research has been performed in order to assess the effect of health  education program based on health belief model (HBM to prevent occupational respiratory   diseases in workers.   Methods   Aquasi-experimental design was used for this interventional study, in which 88 of workers of Borujen industrial town participated, who were randomly assigned to experimental and control group. Data collecting tool were a self-administered questionnaire including 53 questions based on health belief model that was completed by the workers, in addition to the performance check list which was conducted by researcher via insensible controlling the workers' safety behaviour. Validity and reliability of the tools were examined prior to the study. Educational  intervention was conducted in the first stage following by the second data collection one month  later. The data of both experimental and control group were compared statistically before and  after the intervention.   Results   The results showed that the mean of the grade of all parts of health belief model  (HBM and performance mark of the workers about safety and use of personal respiratory  preventive equipment in experimental group after educational intervention compared to prior the  study and also compared to control group were significantly increased.   Conclusion   The results of this survey showed that by enhancement of health belief model (HBM components including

  15. Safety equipment in a reactor

    International Nuclear Information System (INIS)

    Shiratori, Hirozo; Ishiyama, Satoshi; Ugawa, Yukio.

    1976-01-01

    Object: To safely retain, even if fuel should be molten and flown through the bottom of a container in a reactor, the molten fuel to remove heat generation of the fuel to prevent occurrence of a critical trouble. Structure: A reactor container housing a core and coolant has thereunder a separation dome in a central portion thereof and a partitioning plate coaxially and circularly disposed in the periphery of the separation dome, with a tray formed of magnesium oxide being disposed. Further, a cooling path system is provided so as to surround the tray. The cooling path system and the reactor container are surrounded and protected by a reactor wall provided with heat insulating refractory bricks, a coolant pouring system extends through the reactor wall, and the coolant is supplied to the tray. (Furukawa, Y.)

  16. Iloprost infusion by a new device as a portable syringe pump: safety, tolerability and agreement

    Directory of Open Access Journals (Sweden)

    Paola Faggioli

    2012-12-01

    Full Text Available Background Iloprost, prostacyclin (PGI2 analogue, effective in treatment of peripheral arterial disease, secondary Raynaud's phenomenon (RP to connective tissue disease (CTD, vasculitis, pulmonary hypertension, is usually infused through peristaltic pump, or recently through a flow regulator.Materials and methods We tested a new portable syringe pump (Pompa Infonde®, Italfarmaco S.p.A., Cinisello Balsamo, Milano on 120 patients affected by RP to CTD and cryoglobulinaemia, in iloprost therapy with a flow regulator.Results Iloprost infused through portable syringe pump is better tolerated, better appreciated by the patients and nurses and no difference was observed on therapeutic effects, with a lower incidence of side effects statistically significant. Only 3 patients were unable to tolerate the device (2 for changes in pressure and 1 for fear and shifted to traditional method of iloprost infusion.Conclusions Iloprost infusion through the portable syringe Pompa Infonde® appears to be safe, better tolerated, more acceptable and equally effective compared to infusion through a flow regulator.

  17. Automatic filling of liquid nitrogen traps auxiliary safety devices of a pumping unit

    International Nuclear Information System (INIS)

    Chatel, S.

    1969-01-01

    The liquid nitrogen traps in our laboratories are generally filled at fixed time intervals, the supply being cut when the liquid flowing through the overflow pipe acts on a lever to which is fixed a small cup fitted with a hole which allows the water of condensation to escape. This system is reliable. After a certain time however, the escape hole blocks up, water accumulates and the lever arm no longer works properly. Furthermore the duration of any cuts in the current, is added to the fixed time intervals, and in this case there can be a lack of liquid nitrogen for several hours after the current has been restored. The device described here avoids these problems. A stainless steel tube containing a copper wire passes into the trap and is immersed in the nitrogen which boils at its tip. A mercury manometer with concentric reservoirs, or an oil manometer, acting on two micro switches through a floater, records the pressure corresponding to the difference in level and controls the filling operation. If there is a lack of nitrogen, a valve can be closed by means of a falling weight, or a diffusion pump can be cut off; one time switch and at least two relays are required. One single relay can be used to control, the supply of several similar traps placed in series [fr

  18. Equipment considerations

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Trace or ultratrace analyses require that the HPLC equipment used, including the detector, be optimal for such determinations. HPLC detectors are discussed at length in Chapter 4; discussion here is limited to the rest of the equipment. In general, commercial equipment is adequate for trace analysis; however, as the authors approach ultratrace analysis, it becomes very important to examine the equipment thoroughly and optimize it, where possible. For this reason they will review the equipment commonly used in HPLC and discuss the optimization steps. Detectability in HPLC is influenced by two factors (1): (a) baseline noise or other interferences that lead to errors in assigning the baseline absorbance; (b) peak width. 87 refs

  19. Investigations of operational incidents without reactor scram (ATWS) and other selected safety devices

    International Nuclear Information System (INIS)

    Ullrich, W.; Frisch, W.

    1976-09-01

    The most important results may be summarized as follows: Analyses performed up to now show that the primary system is not directly endangered by any overpressure, as 1,1 times the design pressure will not be exceeded in light water reactors. In smaller areas of the reactor core, hazards may exist for several fuel rods. Here, additional tests are still required, especially during failures with a considerable lowering of the water level in the pressure vessel of BWRs or during failures with a very high steam development combined with pump failures in a PWR. Generally, computer models used are suitable to perform ATWS analyses. The confidence in the relatively recent PWR-models should be confirmed by comparison with other models and by reexaminations. Reliability studies of pressure relief systems and of those systems functioning in case of a scram, generally reveal that systems are of a high quality design. Deficiencies insofar as they have been recognized in time, have been eliminated during the licensing procedure. The determined nonavailability data for reactor scrams (RESA) are between 2 x 10 -6 and 5 x 10 -6 . Quantitive treatment of common mode failures is very difficult. First attempts for a solution have been made and results are given in chapters 8 and 9. More extensive studies should be performed in order to adequately quantify the common mode failures and in order to permit them to be handled as an integral part of reliability analyses. Results of analyses performed for BWRs and PWRs led to the conclusion that additional hardware measures on a large scale are not necessary now. Chapter 10, however, proposes possible improvements concerning the existing engineered safegurads for both the BWR and the PWR. These proposals should be discussed with the RSK and manufacturers and utilities as well, in order to achieve an optimum safety standard and to avoid a priori any adverse effect. (orig./HP) [de

  20. Design and construction of engineering test device of a multi-purpose radwaste incineration system

    International Nuclear Information System (INIS)

    Wang Peiyi; Zhou Lianquan; Ma Mingxie; Qiu Mingcai; Yang Liguo; Li Xiaohai; Zhang Xiaobin; Lu Xiaowu; Dong Jingling; Wang Xujin; Li Chuanlian; Yang Baomin

    2002-01-01

    The author describes designs of main un-standard devices, monitoring system and safety system, as well as construction of the engineering system devices for a multi-purpose radwaste incineration system. Un-standard devices include waste crusher, pyrolysis furnace, incinerator furnace, cool stream dilution device and bag filter, etc. The monitoring system mainly includes industrial controlled computer, supported by conventional electrical equipment and instruments. Designs of system safety takes account of containment of radioactive materials fire-prevention, explosion prevention, anti-corrosion, redundance and reservation, emergency system, controlling and electric safety system, etc. Results show that main technological system remains good airtight with leakage ratio at 0.67%

  1. Safety and efficacy of the Aperio thrombectomy device when compared to the Solitaire AB/FR and the Revive devices in a pulsatile flow system.

    Science.gov (United States)

    Saleh, Mahdi; Spence, John Nathan; Nayak, Sanjeev; Pearce, Gillian; Tennuci, Christopher; Roffe, Christine

    2012-01-01

    There are a limited number of studies comparing the Aperio mechanical thrombectomy device to other stent-based devices. In this paper, we compared the Aperio thrombectomy device to the Solitaire AB, FR and Revive devices in a model of the middle cerebral artery (MCA) within a modified pulsatile flow system. Thrombi made of lamb's blood were placed into a pulsatile flow system perfused with Hartmann's solution at 80 bpm with a mean pressure of 90 mm Hg. 30 experiments were run with each device. Recanalization rates were similar for all three devices (90% with the Solitaire AB, FR, 80% with the Revive, and 90% with the Aperio). The mean number of attempts to retrieve the thrombus was also similar for all three devices (1.7 with the Solitaire AB, FR, 2.1 with the Revive, 1.6 with the Aperio). Clot fragmentation and embolization rates revealed no statistical significance but there was a trend towards lower embolization rates with the Aperio (23% compared to 40% with the Solitaire AB, FR and 47% with the Revive). The Aperio was the fastest to recanalize the MCA (mean of 66 seconds compared to 186 seconds for the Solitaire AB, FR and 169 seconds for the Revive). In this in vitro setting, the Aperio device seems to be an efficacious and safe device when compared to other similar clinically used mechanical thrombectomy devices. Larger clinical trials are warranted.

  2. Situation analysis of physical independence of the equipment and safety circuits of Almaraz NPP regarding R.G. 1.75 rev.3 (2005); Analisis de la situacion de la independencia fisica de los equipos y circuitos electricos de seguridad de C. N. Almaraz respecto a la R. G. 1.75 rev 3 (2005)

    Energy Technology Data Exchange (ETDEWEB)

    Seijas Portela, S.

    2010-07-01

    Situation analysis of physical independence of the electrical equipment and circuits CN safety Almaraz about R.G. 1.75 rev. 3. (2005) The aim of this paper is to present the work done in the analysis of the physical separation of redundant safety electrical equipment (emergency diesel generators, medium voltage, electrical cabinets, etc.) and physical separation of circuits and electrical conduits.

  3. Safety of mechanical chest compression devices AutoPulse and LUCAS in cardiac arrest: a randomized clinical trial for non-inferiority

    NARCIS (Netherlands)

    Koster, Rudolph W.; Beenen, Ludo F.; van der Boom, Esther B.; Spijkerboer, Anje M.; Tepaske, Robert; van der Wal, Allart C.; Beesems, Stefanie G.; Tijssen, Jan G.

    2017-01-01

    Aims Mechanical chest compression (CC) during cardiopulmonary resuscitation (CPR) with AutoPulse or LUCAS devices has not improved survival from cardiac arrest. Cohort studies suggest risk of excess damage. We studied safety of mechanical CC and determined possible excess damage compared with manual

  4. Assisting the older driver : intersection design and in-car devices to improve the safety of the older driver. Proefschrift Rijksuniversiteit Groningen RUG, Groningen.

    NARCIS (Netherlands)

    Davidse, R.J.

    2007-01-01

    In this thesis, the main focus was on assistive devices that may improve and prolong the safe mobility of older drivers. Older drivers form a group of road users that is getting more and more attention in road safety research and policy. An important reason for this growing interest is the increase

  5. Clinical efficacy and safety evaluation of a novel fractional unipolar radiofrequency device on facial tightening: A preliminary report.

    Science.gov (United States)

    Suh, Dong Hye; Byun, Eun Jung; Lee, Sang Jun; Song, Kye Yong; Kim, Hei Sung

    2017-06-01

    Previous studies have shown that radiofrequency (RF) energy is safe and effective for improving skin laxity. Unlike monopolar and bipolar devices, little has been studied with the unipolar hand piece. We sought to evaluate the safety and efficacy of a novel fractional unipolar RF device on facial tightening. This was a retrospective, single-center study of 14 subjects with age-related facial laxity who underwent five sessions of fractional unipolar RF at an interval of 2 weeks, and then followed-up for 3 months. Standardized photos were taken at baseline and at 3-months follow-up, and were assessed by two independent dermatologists using a 4-point scale (0=no improvement, 1=mild improvement, 2=moderate improvement, 3=significant improvement). Punch biopsies (2 mm) were performed and a questionnaire was used to evaluate the patient's satisfaction and the incidence of adverse reactions. Fourteen subjects with mild to moderate age-related facial laxity were included in the study. The mean age of the subjects was 49.7 years (range 32-80). 35.7% of the subjects showed significant improvement, 50% moderate improvement, and 14.3% slight improvement of facial laxity in their follow-up photos. About 85.7% of the patients replied that they were either greatly satisfied or satisfied with the results at 3-months follow-up. Skin biopsies revealed an increase in collagen in the dermis. None of the subjects experienced any serious adverse events during or after the procedure. Our findings suggest that fractional Unipolar RF can be safely performed on the face and is effective in skin tightening. It has a great advantage over other forms of RF by being entirely painless. © 2017 Wiley Periodicals, Inc.

  6. Safety, efficacy, and intraoperative characteristics of DisCoVisc and Healon ophthalmic viscosurgical devices for cataract surgery

    Directory of Open Access Journals (Sweden)

    Modi SS

    2011-09-01

    Full Text Available Satish S Modi1, James A Davison2, Tom Walters3 1Seeta Eye Centers, Poughkeepsie, NY, USA; 2Wolfe Clinic, Marshalltown, IA, USA; 3Texas Eye Care, Austin, TX, USA Purpose: To evaluate the safety and efficacy of DisCoVisc ophthalmic viscosurgical device (OVD, Alcon Laboratories, Inc with respect to a comparator, Healon OVD (Advanced Medical Optics, Inc. Patients and methods: In this prospective study, patients with cataracts were randomized to an OVD, and then received phacoemulsification and injection of an intraocular lens. After each surgery, unmasked investigators completed subjective questionnaires about OVD characteristics during each stage of the procedure. Masked technicians evaluated objective safety parameters of intraocular pressure (IOP and endothelial cell density, with 90 days of follow-up. Results: The DisCoVisc OVD group (128 eyes and the Healon OVD group (121 eyes had statistically similar outcomes for IOP and for endothelial cell loss. Subjectively assessed viscosity was statistically different (P < 0.0001, with Healon OVD most often rated “cohesive” and DisCoVisc OVD most often rated “both dispersive and cohesive”. Workspace maintenance differed between groups (P < 0.0001, with workspace most frequently rated “full chamber maintained” when using DisCoVisc OVD and most frequently rated “workspace maintained” when using Healon OVD. “Flat” or “shallow” workspace ratings occurred only in the Healon OVD group. Conclusion: DisCoVisc OVD had both cohesive and dispersive properties, and was safe and effective for every stage of cataract surgery. Keywords: cataract, endothelial cell density, viscoelastic, phacoemulsification

  7. Seismic qualification of equipment

    International Nuclear Information System (INIS)

    Heidebrecht, A.C.; Tso, W.K.

    1983-03-01

    This report describes the results of an investigation into the seismic qualification of equipment located in CANDU nuclear power plants. It is particularly concerned with the evaluation of current seismic qualification requirements, the development of a suitable methodology for the seismic qualification of safety systems, and the evaluation of seismic qualification analysis and testing procedures

  8. Safety Evakuation Of Triga-2000 Reactor Operation Viewed From Safety Culture

    International Nuclear Information System (INIS)

    Karliana, Itjeu

    2001-01-01

    The safety evaluation activities of TRIGA-2000 operation viewed from safety culture performed by questioners data collected from the operators and supervisor site of TRIGA-2000 P3TN, Bandung. There are 9 activity aspects surveyed, for instant to avail the policy of safety from their chairman, safety management, education and training, emergency aids planning, safety consultancy, accident information, safety analysis, safety devices, safety and occupational health. The surveying undertaken by filling the questioner that containing of 9 activity aspects and 20 samples of employees. The safety evaluation results' of the operation personnel in TRIGA-2000 P3TN are good implemented by both the operators and supervisors should be improve and attention need to provide the equipment's. The education and training especially for safety refreshment must be performing

  9. [Equipping the bacteriological laboratories of a tuberculosis service as the most important element of assurance of the quality and safety of their work].

    Science.gov (United States)

    Sevast'ianova, E V; Martynova, L P; Barilo, V N; Golyshevskaia, V I; Shul'gina, M V

    2009-01-01

    By taking into account the present requirements for the equipping of the laboratories, the authors have drawn up the minimum standard list of equipment, as well as a list of additional equipment for the specialized bacteriological laboratory of a tuberculosis-controlling institution, which performs microbiological studies for the diagnosis and control of chemotherapy for tuberculosis. The specifications and characteristics of the baric types of equipment used to fit out the laboratories under the present conditions are described. Equipping the laboratories in accordance with the draw-up lists is shown to ensure a qualitative, effective, and safe work. Recommendations on how to supply the laboratories with equipment, to make the optimal choice, and to use consumables for tests are given.

  10. 30 CFR 77.506 - Electric equipment and circuits; overload and short-circuit protection.

    Science.gov (United States)

    2010-07-01

    ... short-circuit protection. 77.506 Section 77.506 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION... circuits; overload and short-circuit protection. Automatic circuit-breaking devices or fuses of the correct type and capacity shall be installed so as to protect all electric equipment and circuits against short...

  11. Radiation emitting devices regulations

    International Nuclear Information System (INIS)

    1970-01-01

    The Radiation Emitting Devices Regulations are the regulations referred to in the Radiation Emitting Devices Act and relate to the operation of devices. They include standards of design and construction, standards of functioning, warning symbol specifications in addition to information relating to the seizure and detention of machines failing to comply with the regulations. The radiation emitting devices consist of the following: television receivers, extra-oral dental x-ray equipment, microwave ovens, baggage inspection x-ray devices, demonstration--type gas discharge devices, photofluorographic x-ray equipment, laser scanners, demonstration lasers, low energy electron microscopes, high intensity mercury vapour discharge lamps, sunlamps, diagnostic x-ray equipment, ultrasound therapy devices, x-ray diffraction equipment, cabinet x-ray equipment and therapeutic x-ray equipment

  12. A review of the literature pertaining to the efficacy, safety, educational requirements, uses and usage of mechanical adjusting devices

    Science.gov (United States)

    Taylor, Shane H; Arnold, Nicole D; Biggs, Lesley; Colloca, Christopher J; Mierau, Dale R; Symons, Bruce P; Triano, John J

    2004-01-01

    Over the past decade, mechanical adjusting devices (MADs) were a major source of debate within the Chiropractors’ Association of Saskatchewan (CAS). Since Saskatchewan was the only jurisdiction in North America to prohibit the use of MADs, the CAS established a committee in 2001 to review the literature on MADs. The committee evaluated the literature on the efficacy, safety, and uses of moving stylus instruments within chiropractic practice, and the educational requirements for chiropractic practice. Following the rating criteria for the evaluation of evidence, as outlined in the Clinical Guidelines for Chiropractic Practice in Canada (1994), the committee reviewed 55 articles – all of which pertained to the Activator. Of the 55 articles, 13 were eliminated from the final study. Of the 42 remaining articles, 6 were rated as class 1 evidence; 11 were rated as class 2 evidence and 25 were rated as class 3 evidence. In this article – the second in a series of two – we review the results of uses and usage, safety and educational requirements. Of the 30 articles designated under the category of usage, 3 were rated as Class 1 evidence; 9 studies were classified as Class 2 evidence and 18 were rated as Class 3 evidence. Overall the committee reached consensus that in clinical practice, there is broad application of these procedures. A minority report was written arguing that the reviewer was unable to reach a conclusion about the use of the Activator Instrument other than it is used as a clinical and research tool. Of the 16 studies that dealt either explicitly or implicitly with safety, 4 were Class 1 evidence; 3 were Class 2 evidence and 9 were Class 3 evidence. Overall the committee reached consensus that the evidence supports that the Activator instrument is safe and has no more relative risk than do manual HVLA procedures. A minority report was written arguing that there is no evidence either to support or refute the view that MAD is safe. Of the 5 studies

  13. Safety-related control air systems - approved 1977

    International Nuclear Information System (INIS)

    Anon.

    1978-01-01

    This standard applies to those portions of the control air system that furnish air required to support, control, or operate systems or portions of systems that are safety related in nuclear power plants. This standard relates only to the air supply system(s) for safety-related air operated devices and does not apply to the safety-related air operated device or to air operated actuators for such devices. The objectives of this standard are to provide (1) minimum system design requirements for equipment, piping, instruments, controls, and wiring that constitute the air supply system; and (2) the system and component testing and maintenance requirements

  14. EAS Equipment Authorization Grantee Registrations

    Data.gov (United States)

    Federal Communications Commission — EAS (Equipment Authorization System). Radio Frequency (RF) devices are required to be properly authorized under 47 CFR Part 2 prior to being marketed or imported...

  15. Functional safety requirements of the propulsion and power supply equipment of the MAGLEV system; Umgang mit funktionalen Sicherheitsanforderungen bei Antrieb und Energieversorgung der Magnetbahn

    Energy Technology Data Exchange (ETDEWEB)

    Stephan, A. [IFB Inst. fuer Bahntechnik GmbH, Dresden (Germany)

    2008-07-01

    In the Transrapid high-speed MAGLEV railway system, the operating control subsystem provides for the higher-level safety function. Within the system also selected components of the stationary linear-motor drive have important safety functions. Under the approval procedure, the safety-relevant functions must be certified. This makes specific requirements on the development and integration of the components used. (orig.)

  16. Reactor safety

    International Nuclear Information System (INIS)

    Butz, H.P.; Heuser, F.W.; May, H.

    1985-01-01

    The paper comprises an introduction into nuclear physics bases, the safety concept generally speaking, safety devices of pwr type reactors, accident analysis, external influences, probabilistic safety assessment and risk studies. It further describes operational experience, licensing procedures under the Atomic Energy Law, research in reactor safety and the nuclear fuel cycle. (DG) [de

  17. The history of anaesthetic equipment evaluation in the United Kingdom: lessons for developing future strategy.

    Science.gov (United States)

    Wilkes, A R; Pandit, J J; O'Sullivan, E

    2011-12-01

    Recent guidance published by the Association of Anaesthetists of Great Britain and Ireland encourages the purchase of equipment based on evidence of safety and performance. For many years, evidence of the safety and performance of anaesthetic equipment was published by various government departments and agencies. However, these schemes were gradually eroded over time such that many devices entered the market with little or no clinical evidence of their efficacy. This recently led to the Difficult Airway Society's issuing guidance to its members on how best to select new airway devices; guidance that was based on the available evidence. This article provides a short history of the evaluation of anaesthetic equipment in the United Kingdom. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

  18. Two Different Maintenance Strategies in the Hospital Environment: Preventive Maintenance for Older Technology Devices and Predictive Maintenance for Newer High-Tech Devices.

    Science.gov (United States)

    Sezdi, Mana

    2016-01-01

    A maintenance program generated through the consideration of characteristics and failures of medical equipment is an important component of technology management. However, older technology devices and newer high-tech devices cannot be efficiently managed using the same strategies because of their different characteristics. This study aimed to generate a maintenance program comprising two different strategies to increase the efficiency of device management: preventive maintenance for older technology devices and predictive maintenance for newer high-tech devices. For preventive maintenance development, 589 older technology devices were subjected to performance verification and safety testing (PVST). For predictive maintenance development, the manufacturers' recommendations were used for 134 high-tech devices. These strategies were evaluated in terms of device reliability. This study recommends the use of two different maintenance strategies for old and new devices at hospitals in developing countries. Thus, older technology devices that applied only corrective maintenance will be included in maintenance like high-tech devices.

  19. Plant operation monitoring method and device therefor

    International Nuclear Information System (INIS)

    Ando, Tsugio; Matsuki, Tsutomu.

    1997-01-01

    The present invention provides a method of and a device for monitoring the operation of a nuclear power plant during operation, which improves the safety and reliability of operation without increasing an operator's burden. Namely, a chief in charge orally instruct an operation to an operator upon the operation of a plant constituent equipment. The operator points the equipment and calls the name. Actual operation instruction for the equipment is inputted after confirmation by oral response. The voices of theses series of operation instruction/point-calling/response confirmation are taken into a voice recognition processing device. The processing device discriminates each of the person who calls, and discriminates the content of the calls and objective equipments to be operated. Then, the series of procedures and contents of the operation for the equipments previously disposed in the data base are compared with the order of inputted calls, discriminated contents and the objective equipments to be operated. If they are not agreed with each other, the operation instruction is blocked even if actual operation instructions are inputted. (I.S.)

  20. SAFETY

    CERN Multimedia

    C. Schaefer and N. Dupont

    2013-01-01

      “Safety is the highest priority”: this statement from CERN is endorsed by the CMS management. An interpretation of this statement may bring you to the conclusion that you should stop working in order to avoid risks. If the safety is the priority, work is not! This would be a misunderstanding and misinterpretation. One should understand that “working safely” or “operating safely” is the priority at CERN. CERN personnel are exposed to different hazards on many levels on a daily basis. However, risk analyses and assessments are done in order to limit the number and the gravity of accidents. For example, this process takes place each time you cross the road. The hazard is the moving vehicle, the stake is you and the risk might be the risk of collision between both. The same principle has to be applied during our daily work. In particular, keeping in mind the general principles of prevention defined in the late 1980s. These principles wer...