WorldWideScience

Sample records for equipment interface test

  1. Vehicle to Electric Vehicle Supply Equipment Smart Grid Communications Interface Research and Testing Report

    Energy Technology Data Exchange (ETDEWEB)

    Kevin Morrow; Dimitri Hochard; Jeff Wishart

    2011-09-01

    Plug-in electric vehicles (PEVs), including battery electric, plug-in hybrid electric, and extended range electric vehicles, are under evaluation by the U.S. Department of Energy's Advanced Vehicle Testing Activity (AVTA) and other various stakeholders to better understand their capability and potential petroleum reduction benefits. PEVs could allow users to significantly improve fuel economy over a standard hybrid electric vehicles, and in some cases, depending on daily driving requirements and vehicle design, PEVs may have the ability to eliminate petroleum consumption entirely for daily vehicle trips. The AVTA is working jointly with the Society of Automotive Engineers (SAE) to assist in the further development of standards necessary for the advancement of PEVs. This report analyzes different methods and available hardware for advanced communications between the electric vehicle supply equipment (EVSE) and the PEV; particularly Power Line Devices and their physical layer. Results of this study are not conclusive, but add to the collective knowledge base in this area to help define further testing that will be necessary for the development of the final recommended SAE communications standard. The Idaho National Laboratory and the Electric Transportation Applications conduct the AVTA for the United States Department of Energy's Vehicle Technologies Program.

  2. Equipment for hydraulic testing

    International Nuclear Information System (INIS)

    Jacobsson, L.; Norlander, H.

    1981-07-01

    Hydraulic testing in boreholes is one major task of the hydrogeological program in the Stripa Project. A new testing equipment for this purpose was constructed. It consists of a downhole part and a surface part. The downhole part consists of two packers enclosing two test-sections when inflated; one between the packers and one between the bottom packer and the bottom of the borehole. A probe for downhole electronics is also included in the downhole equipment together with electrical cable and nylon tubing. In order to perform shut-in and pulse tests with high accuracy a surface controlled downhole valve was constructed. The surface equipment consists of the data acquisition system, transducer amplifier and surface gauges. In the report detailed descriptions of each component in the whole testing equipment are given. (Auth.)

  3. Electromagnetic Interface Testing Facility

    Data.gov (United States)

    Federal Laboratory Consortium — The Electromagnetic Interface Testing facilitysupports such testing asEmissions, Field Strength, Mode Stirring, EMP Pulser, 4 Probe Monitoring/Leveling System, and...

  4. Equipment fragility testing

    International Nuclear Information System (INIS)

    Holman, G.S.; Chou, C.K.; Cummings, G.E.

    1985-01-01

    Current probabilistic risk assessment (PRA) methods for nuclear power plants utilize component fragilities which are for the most part based on a limited data base and engineering judgement. The seismic design of components is based on code limits and NRC requirements that do not reflect the actual capacity of a component to resist failure. In order to improve the present component fragility data base and establish component seismic design margins, the NRC has commissioned a projected three-year program to compile existing fragilities data and at the same time independently perform fragilities tests on selected mechanical and electrical components. This paper presents the planning and technical approach being taken by LLNL in the NRC Component Fragility Program

  5. AVM branch vibration test equipment

    International Nuclear Information System (INIS)

    Anne, J.P.

    1995-01-01

    An inventory of the test equipment of the AVM Branch ''Acoustic and Vibratory Mechanics Analysis Methods'' group has been undertaken. The purpose of this inventory is to enable better acquaintance with the technical characteristics of the equipment, providing an accurate definition of their functionalities, ad to inform potential users of the possibilities and equipment available in this field. The report first summarizes the various experimental surveys conduced. Then, using the AVM equipment database to draw up an exhaustive list of available equipment, it provides a full-scope picture of the vibration measurement systems (sensors, conditioners and exciters) and data processing resources commonly used on industrial sites and in laboratories. A definition is also given of a mobile test unit, called 'shelter', and a test bench used for the testing and performance rating of the experimental analysis methods developed by the group. The report concludes with a description of two fixed installations: - the calibration bench ensuring the requisite quality level for the vibration measurement systems ; - the training bench, whereby know-how acquired in the field in the field of measurement and experimental analysis processes is made available to others. (author). 27 refs., 15 figs., 2 appends

  6. Principles of interfacing computers to medical equipment.

    Science.gov (United States)

    Francis, J L; Martin, T R

    1990-12-01

    Table 3 shows a comparison of the interface standards considered. RS232 has the advantages of availability, flexibility and low cost. Variants on the standard overcome its limitations in data-rate and distance. The Centronics parallel standard is available on most personal computers and is particularly suitable for high data-rates over short distances. Other PC standards such as SCSI are special-purpose interfaces and therefore more difficult to use. GPIB is a robust and well-specified standard often used for the control of laboratory instruments.

  7. Imaging Sensor Flight and Test Equipment Software

    Science.gov (United States)

    Freestone, Kathleen; Simeone, Louis; Robertson, Byran; Frankford, Maytha; Trice, David; Wallace, Kevin; Wilkerson, DeLisa

    2007-01-01

    The Lightning Imaging Sensor (LIS) is one of the components onboard the Tropical Rainfall Measuring Mission (TRMM) satellite, and was designed to detect and locate lightning over the tropics. The LIS flight code was developed to run on a single onboard digital signal processor, and has operated the LIS instrument since 1997 when the TRMM satellite was launched. The software provides controller functions to the LIS Real-Time Event Processor (RTEP) and onboard heaters, collects the lightning event data from the RTEP, compresses and formats the data for downlink to the satellite, collects housekeeping data and formats the data for downlink to the satellite, provides command processing and interface to the spacecraft communications and data bus, and provides watchdog functions for error detection. The Special Test Equipment (STE) software was designed to operate specific test equipment used to support the LIS hardware through development, calibration, qualification, and integration with the TRMM spacecraft. The STE software provides the capability to control instrument activation, commanding (including both data formatting and user interfacing), data collection, decompression, and display and image simulation. The LIS STE code was developed for the DOS operating system in the C programming language. Because of the many unique data formats implemented by the flight instrument, the STE software was required to comprehend the same formats, and translate them for the test operator. The hardware interfaces to the LIS instrument using both commercial and custom computer boards, requiring that the STE code integrate this variety into a working system. In addition, the requirement to provide RTEP test capability dictated the need to provide simulations of background image data with short-duration lightning transients superimposed. This led to the development of unique code used to control the location, intensity, and variation above background for simulated lightning strikes

  8. Interface-based software testing

    OpenAIRE

    Aziz Ahmad Rais

    2016-01-01

    Software quality is determined by assessing the characteristics that specify how it should work, which are verified through testing. If it were possible to touch, see, or measure software, it would be easier to analyze and prove its quality. Unfortunately, software is an intangible asset, which makes testing complex. This is especially true when software quality is not a question of particular functions that can be tested through a graphical user interface. The primary objective of softwar...

  9. Interface-based software testing

    Directory of Open Access Journals (Sweden)

    Aziz Ahmad Rais

    2016-10-01

    Full Text Available Software quality is determined by assessing the characteristics that specify how it should work, which are verified through testing. If it were possible to touch, see, or measure software, it would be easier to analyze and prove its quality. Unfortunately, software is an intangible asset, which makes testing complex. This is especially true when software quality is not a question of particular functions that can be tested through a graphical user interface. The primary objective of software architecture is to design quality of software through modeling and visualization. There are many methods and standards that define how to control and manage quality. However, many IT software development projects still fail due to the difficulties involved in measuring, controlling, and managing software quality. Software quality failure factors are numerous. Examples include beginning to test software too late in the development process, or failing properly to understand, or design, the software architecture and the software component structure. The goal of this article is to provide an interface-based software testing technique that better measures software quality, automates software quality testing, encourages early testing, and increases the software’s overall testability

  10. Weight/balance portable test equipment

    International Nuclear Information System (INIS)

    Whitlock, R.W.

    1994-01-01

    This document shows the general layout, and gives a part description for the weight/balance test equipment. This equipment will aid in the regulation of the leachate loading of tanker trucks. The report contains four drawings with part specifications. The leachate originates from lined trenches

  11. Room temperature cryogenic test interface

    International Nuclear Information System (INIS)

    Faris, S. M.; Davidson, A.; Moskowitz, P. A.; Sai-Halasz, G. A.

    1985-01-01

    This interface permits the testing of high speed semiconductor devices (room-temperature chips) by a Josephson junction sampling device (cryogenic chip) without intolerable loss of resolution. The interface comprises a quartz pass-through plug which includes a planar transmission line interconnecting a first chip station, where the cryogenic chip is mounted, and a second chip station, where the semiconductor chip to be tested is temporarily mounted. The pass-through plug has a cemented long half-cylindrical portion and short half-cylindrical portion. The long portion carries the planar transmission line, the ends of which form the first and second chip mounting stations. The short portion completes the cylinder with the long portion for part of its length, where a seal can be achieved, but does not extend over the chip mounting stations. Sealing is by epoxy cement. The pass-through plug is sealed in place in a flange mounted to the chamber wall. The first chip station, with the cryogenic chip attached, extends into the liquid helium reservoir. The second chip station is in the room temperature environment required for semiconductor operation. Proper semiconductor operating temperature is achieved by a heater wire and control thermocouple in the vicinity of each other and the second chip mounting station. Thermal isolation is maintained by vacuum and seals. Connections for power and control, for test result signals, for temperature control and heating, and for vacuum complete the test apparatus

  12. Human-centered design of the human-system interfaces of medical equipment: thyroid uptake system

    International Nuclear Information System (INIS)

    Monteiro, Jonathan K.R.; Farias, Marcos S.; Santos, Isaac J.A. Luquetti; Monteiro, Beany G.

    2013-01-01

    Technology plays an important role in modern medical centers, making healthcare increasingly complex, relying on complex technical equipment. This technical complexity is particularly noticeable in the nuclear medicine. Poorly design human-system interfaces can increase the risks for human error. The human-centered approach emphasizes the development of the equipment with a deep understanding of the users activities, current work practices, needs and abilities of the users. An important concept of human-centered design is that the ease-of-use of the equipment can be ensured only if users are actively incorporated in all phases of the life cycle of design process. Representative groups of users are exposed to the equipment at various stages in development, in a variety of testing, evaluation and interviewing situations. The users feedback obtained is then used to refine the design, with the result serving as input to the next interaction of design process. The limits of the approach are that the users cannot address any particular future needs without prior experience or knowledge about the equipment operation. The aim of this paper is to present a methodological framework that contributes to the design of the human-system interfaces, through an approach related to the users and their activities. A case study is described in which the methodological framework is being applied in development of new human-system interfaces of the thyroid uptake system. (author)

  13. TMACS Test Procedure TP011: Panalarm Interface

    International Nuclear Information System (INIS)

    Seghers, R.; Washburn, S.J.

    1994-01-01

    The TMACS Software Test Procedures translate the project's acceptance criteria into test steps. The TMACS Test Plan (WHC-SD-WM-TP-148) is fulfilled when all Test Cases are approved. This Test Procedure tests the TMACS Panalarm Interface functions

  14. Operability test procedure [Tank] 241-SY-101 equipment removal system

    International Nuclear Information System (INIS)

    Mast, J.C.

    1994-01-01

    The 241-SY-101 equipment removal system (ERS) consists of components, equipment, instrumentation and procedures that will provide the means to disconnect, retrieve, contain, load and transport the Mitigation Pump Assembly (MPA) from waste Tank 241-SY-101 to the Central Waste Complex (CWC). The Operability Test Procedure (OTP) will test the interfaces between ERS components and will rehearse the procedure for MPA removal and transportation to the extent they can be mocked-up at the CTF (Cold Test Facility). At the conclusion of the OTP, the ERS components and equipment will be removed from the CTF, entered into the Component Based Recall System (CBRS), and stored until needed for actual MPA removal and transportation

  15. Communication interface and graphic module for audiometry equipment.

    Science.gov (United States)

    Gutiérrez Martinez, Josefina; Barraza López, Fernando; Guadarrama Lara, Alberto; Núñez Gaona, Marco Antonio; Delgado Esquerra, Ruth; Gutiérrez Farfán, Ileana

    2009-01-01

    The National Rehabilitation Institute (INR) in Mexico City purchased 12 Madsen Orbiter 922 audiometers in 2006. While this audiometer is excellent for diagnosing the degree and type of hearing loss, it has presented problems in transfering, saving and printing the results of special tests and logoaudiometry from audiometer to workstation with the NOAH-3 system. The data are lost when the audiometer is turned off or a new patient is captured. There is no database storing and, shortly after the results have been printed on the thermal paper, the audiograms are erased. This problem was addressed by designing and implementing the InterAudio (AAMS) communication and graphical interface. The limitations and scope of the Automatic Audiometric Measurement System were analyzed, then a search of technical information was performed that included the resources for designing, developing and implementing the transfer interface, the user's graphical module requirements, and the tools for printing and saving the study.

  16. Equipment qualification testing - a practical approach

    International Nuclear Information System (INIS)

    Davies, G.A.; McDougall, R.I.; Poirier, M.P.

    1996-01-01

    When nuclear safety equipment is credited with a Required Safety Function it must properly perform that function to facilitate safe control and/or shutdown of the plant during a design basis accident. When such equipment is required to be environmentally (EQ) and/or seismically qualified (SQ) for safety related use in CANDU nuclear power plants, the preferred method of qualification is by type testing. The qualification testing process requires that the test specimen equipment be subjected to the aging stressors associated with the normal service conditions that it would experience during it's required qualified (or service) life. Following the aging process, the test specimen is in a condition representative of that in which it would be at the end of its service life in the plant. The test specimen is then subjected to a simulated accident during which it must satisfy performance requirements thereby demonstrating that it can perform its required safety function. The performance requirements specified for the qualification testing must be designed to ensure that satisfactory performance of the safety function is demonstrated during the qualification program. This paper provides descriptions of practical methods used in the deriving and satisfying of relevant performance requirements during the qualification testing of safety related equipment. (author)

  17. Testing of FFTF fuel handling equipment

    International Nuclear Information System (INIS)

    Coleman, D.W.; Grazzini, E.D.; Hill, L.F.

    1977-07-01

    The Fast Flux Test Facility has several manual/computer controlled fuel handling machines which are exposed to severe environments during plant operation but still must operate reliably when called upon for reactor refueling. The test programs for two such machines--the Closed Loop Ex-Vessel Machine and the In-Vessel Handling Machine--are described. The discussion centers on those areas where design corrections or equipment repairs substantiated the benefits of a test program prior to plant operation

  18. LESSONS LEARNED IN TESTING OF SAFEGUARDS EQUIPMENT

    International Nuclear Information System (INIS)

    Pepper, S.; Farnitano, M.; Carelli, J.; Hazeltine, J.; Bailey, D.

    2001-01-01

    The International Atomic Energy Agency's (IAEA) Department of Safeguards uses complex instrumentation for the application of safeguards at nuclear facilities around the world. Often, this equipment is developed through cooperation with member state support programs because the Agency's requirements are unique and are not met by commercially available equipment. Before approving an instrument or system for routine inspection use, the IAEA subjects it to a series of tests designed to evaluate its reliability. In 2000, the IAEA began to observe operational failures in digital surveillance systems. In response to the observed failures, the IAEA worked with the equipment designer and manufacturer to determine the cause of failure. An action plan was developed to correct the performance issues and further test the systems to make sure that additional operational issues would not surface later. This paper addresses the steps taken to address operation issues related to digital image surveillance systems and the lessons learned during this process

  19. Lessons learned in testing of Safeguards equipment

    International Nuclear Information System (INIS)

    Pepper, Susan; Farnitano, Michael; Carelli, Joseph

    2001-01-01

    Upgrade Travel Funding' - This subtask provides funding for the upgrade of DIS equipment installed in the field; E.125.3, 'DIS Radiation Field Characterization' - This subtask provides for the procurement by the IAEA of radiation measurement equipment and technical assistance for the characterization of radiation conditions in the locations where DIS will be installed. This will help the IAEA ensure that the design specifications for the equipment are consistent with the location where the instrument will be used; E.125.4, 'DIS Design Limit Testing and Advise to Strengthen IAEA's Current Equipment Qualification Criteria' - Under this subtask, Wyle Laboratories and Quanterion Solutions will conduct SDIS design limit testing, including harsh environmental testing and accelerated aging, to determine the expected lifetime and produce a design limit report to include maximum operating environment vs. design limit analysis. Additionally, this task will include the development of a strengthened environmental qualification test plan and reliability and maintainability definition methodology for all safeguards equipment. The implementation of new equipment by the Department of Safeguards is costly. Expected costs associated with the implementation of equipment include capital costs, training and in some cases travel. The cost is dramatically increased when operational issues arise due to the costs of studying the issues, modifying and upgrading the equipment and additional travel. The U.S. Support Program believes that the IAEA's Division of Safeguards Technical Support (SGTS) must strengthen its equipment-testing program to ensure that the equipment it approves for inspection use is reliable and will not place additional burden on the Department of Safeguards' maintenance and inspection staff. The U.S. Support Program recognizes that SGTS already requires a series of fundamentally important and revealing tests, but we believe that additional tests should be added to the testing

  20. Development of Partial Discharging Simulation Test Equipment

    Science.gov (United States)

    Kai, Xue; Genghua, Liu; Yan, Jia; Ziqi, Chai; Jian, Lu

    2017-12-01

    In the case of partial discharge training for recruits who lack of on-site work experience, the risk of physical shock and damage of the test equipment may be due to the limited skill level and improper operation by new recruits. Partial discharge simulation tester is the use of simulation technology to achieve partial discharge test process simulation, relatively true reproduction of the local discharge process and results, so that the operator in the classroom will be able to get familiar with and understand the use of the test process and equipment.The teacher sets up the instrument to display different partial discharge waveforms so that the trainees can analyze the test results of different partial discharge types.

  1. Acceptance Test Report for the 241-AZ-101 Ultrasonic Interface Level Analyzer

    International Nuclear Information System (INIS)

    ANDREWS, J.E.

    2000-01-01

    This document comprises the Acceptance Test Report for the 241-AZ-101 Ultrasonic Interface Level Analyzer. This document presents the results of Acceptance Testing of the 241-AZ-101 Ultrasonic Interface Level Analyzers (URSILLAs). Testing of the URSILLAs was performed in accordance with ATP-260-001, ''URSILLA Pre-installation Acceptance Test Procedure''. The objective of the testing was to verify that all equipment and components function in accordance with design specifications and original equipment manufacturer's specifications

  2. Test and Analysis of Metallurgical Converter Equipment

    Directory of Open Access Journals (Sweden)

    Shan Pang

    2013-05-01

    Full Text Available Oxygen top-blow converter is the main equipment in steel making, and its work reliability decides the security and economy of steel production. Therefore, how to design and test analysis of convertor has been an important subject of industry research. Geometric modelling and structure analysis of converter tilting device by using Pro/E program .The design Principle, basic design structure were analyzed in detail. The computer simulation software of metallurgical converter equipment and how to use it were introduced .It developed by VC++ software. The position of barycentre and moment curve in No.3 and No.4 are calculated. The converter acceleration down dip can be resolved by comparing the moment curve and center curve.

  3. GMS/DACS interface acceptance test procedure

    International Nuclear Information System (INIS)

    Zuehlke, A.C.

    1994-01-01

    The readiness of the Data Acquisition and Control System (DACS) to provide monitoring of existing, and newly installed, instrumentation associated with the SY-101 tank Gas Monitoring Systems will be systematically evaluated by performance of this procedure. All new alarms will be verified to function at the required setpoints. The change of I/O Drop 17 to I/O Drop 13 will be checked to verify that all associated alarms and screen displays are correct. All new or changed Control Screens which provide operator interface with the Gas Monitoring Systems readouts during operations will be verified to be adequate and correct. The DACS, which is housed in a trailer located just outside of the north fence at the SY tank farm, receives input signals from a variety of sensors located in and around the SY-101 tank. These sensors provide information such as: tank vapor space and ventilation system H 2 concentration; tank waste temperature; tank pressure; waste density; operating pump parameters such as speed, flow, rotational position, discharge pressure, and internal temperature; strain (for major equipment); and waste level. The output of these sensors is conditioned and transmitted to the DACS computers where these signals are displayed, recorded, and monitored for out-of-specification conditions. If abnormal conditions are detected, then, in certain situations, the DACS automatically generates alarms and causes the system to abort pump operations. The portions of the system to be tested include: new RGA5 gas monitor; existing gas chromatographs; FTIR; B ampersand K (Photo) NH 3 equipment; any new or changed Genesis screens; and I/O Drop 13

  4. Earth Observing System (EOS)/ Advanced Microwave Sounding Unit-A (AMSU-A): Special Test Equipment. Software Requirements

    Science.gov (United States)

    Schwantje, Robert

    1995-01-01

    This document defines the functional, performance, and interface requirements for the Earth Observing System/Advanced Microwave Sounding Unit-A (EOS/AMSU-A) Special Test Equipment (STE) software used in the test and integration of the instruments.

  5. Research on the Reliability Testing of Electrical Automation Control Equipment

    OpenAIRE

    Yongjie Luo

    2014-01-01

    According to the author’s many years’ work experience, this paper first discusses the concepts of electrical automation control equipment reliability testing, and then analyzes the test method of electrical automation control equipment reliability testing, finally, on this basis, this article discusses how to determine the reliability test method of electrical automation control equipment. Results of this study will provide a useful reference for electrical automation control equipment reliab...

  6. MPLM On-Orbit Interface Dynamic Flexibility Modal Test

    Science.gov (United States)

    Bookout, Paul S.; Rodriguez, Pedro I.; Tinson, Ian; Fleming, Paolo

    2001-01-01

    Now that the International Space Station (ISS) is being constructed, payload developers have to not only verify the Shuttle-to-payload interface, but also the interfaces their payload will have with the ISS. The Multi Purpose Logistic Module (MPLM) being designed and built by Alenia Spazio in Torino, Italy is one such payload. The MPLM is the primary carrier for the ISS Payload Racks, Re-supply Stowage Racks, and the Resupply Stowage Platforms to re-supply the ISS with food, water, experiments, maintenance equipment and etc. During the development of the MPLM there was no requirement for verification of the on-orbit interfaces with the ISS. When this oversight was discovered, all the dynamic test stands had already been disassembled. A method was needed that would not require an extensive testing stand and could be completed in a short amount of time. The residual flexibility testing technique was chosen. The residual flexibility modal testing method consists of measuring the free-free natural frequencies and mode shapes along with the interface frequency response functions (FRF's). Analytically, the residual flexibility method has been investigated in detail by, MacNeal, Martinez, Carne, and Miller, and Rubin, but has not been implemented extensively for model correlation due to difficulties in data acquisition. In recent years improvement of data acquisition equipment has made possible the implementation of the residual flexibility method as in Admire, Tinker, and Ivey, and Klosterman and Lemon. The residual flexibility modal testing technique is applicable to a structure with distinct points (DOF) of contact with its environment, such as the MPLM-to-Station interface through the Common Berthing Mechanism (CBM). The CBM is bolted to a flange on the forward cone of the MPLM. During the fixed base test (to verify Shuttle interfaces) some data was gathered on the forward cone panels. Even though there was some data on the forward cones, an additional modal test was

  7. Constructing a User Interface for Cellular Phones Using Equipment and its Relations

    Directory of Open Access Journals (Sweden)

    Misayo Kitamura

    2003-04-01

    Full Text Available In a domain of SCADA (Supervisory Control And Data Acquisition systems, it is necessary to obtain information about plants such as water plants in remote places using a cellular phone in order to ascertain plant status in case of emergency.T o utilize the small screen of a cellular phone and to eliminate the engineering cost of creating de.nition data to show plant status, a method of constructing user interface using equipment in the plant and its relations is proposed. In this method, some equipment is selected from all supervised equipment using the relations between the equipment, and then the content to be displayed is generated dynamically using the selected equipment. The equipment in plants is organized as a graph structure, which involves the equipment and the relations between the equipment.T he relations adopted in this method are both the physical connections between the equipment and the conceptual relationships.The result of the selection depends on the relations and their parameter values called the context dependent weight, which changes dynamically by viewpoints.

  8. Acceptance Test Report for the 241-AZ-101 Ultrasonic Interface Level Analyzer

    Energy Technology Data Exchange (ETDEWEB)

    ANDREWS, J.E.

    2000-01-27

    This document comprises the Acceptance Test Report for the 241-AZ-101 Ultrasonic Interface Level Analyzer. This document presents the results of Acceptance Testing of the 241-AZ-101 Ultrasonic Interface Level Analyzers (URSILLAs). Testing of the URSILLAs was performed in accordance with ATP-260-001, ''URSILLA Pre-installation Acceptance Test Procedure''. The objective of the testing was to verify that all equipment and components function in accordance with design specifications and original equipment manufacturer's specifications.

  9. The digital ultrasonic test unit for automatic equipment

    International Nuclear Information System (INIS)

    Hiraoka, T.; Matsuyama, H.

    1976-01-01

    The operations and features of the ultrasonic test unit used and the digital data processing techniques employed are described. This unit is used for a few hundred multi-channel automatic ultrasonic test equipment

  10. A Test Procedure for Determining Models of LV Equipment

    NARCIS (Netherlands)

    Cuk, Vladimir; Cobben, Joseph F.G.; Kling, Wil L.; Timens, R.B.; Leferink, Frank Bernardus Johannes

    2009-01-01

    An automated test technique for determining parameters of low voltage equipment is presented in the paper. The aim of this research is to obtain simple models of household, office and industrial equipment which could be used to predict power quality problems during the design of low voltage

  11. Framed bit error rate testing for 100G ethernet equipment

    DEFF Research Database (Denmark)

    Rasmussen, Anders; Ruepp, Sarah Renée; Berger, Michael Stübert

    2010-01-01

    rate. As the need for 100 Gigabit Ethernet equipment rises, so does the need for equipment, which can properly test these systems during development, deployment and use. This paper presents early results from a work-in-progress academia-industry collaboration project and elaborates on the challenges...

  12. Waste Handling Equipment Development Test and Evaluation Study

    International Nuclear Information System (INIS)

    R.L. Tome

    1998-01-01

    The purpose of this study is to identify candidate Monitored Geologic Repository (MGR) surface waste handling equipment for development testing. This study will also identify strategies for performing the development tests. Development testing shall be implemented to support detail design and reduce design risks. Development testing shall be conducted to confirm design concepts, evaluate alternative design concepts, show the availability of needed technology, and provide design documentation. The candidate equipment will be selected from MGR surface waste handling equipment that is the responsibility of the Management and Operating Contractor (M and O) Surface Design Department. The equipment identified in this study is based on Viability Assessment (VA) design. The ''Monitored Geologic Repository Test and Evaluation Plan'' (MGR T and EP), Reference 5.1, was used as a basis for this study. The MGR T and EP reflects the extent of test planning and analysis that can be conducted, given the current status of the MGR requirements and latest VA design information. The MGR T and EP supports the appropriate sections in the license application (LA) in accordance with 10 CFR 60.2 1(c)(14). The MGR T and EP describes the following test activities: site characterization to confirm, by test and analysis, the suitability of the Yucca Mountain site for housing a geologic repository; development testing to investigate and document design concepts to reduce risk; qualification testing to verify equipment compliance with design requirements, specifications, and regulatory requirements; system testing to validate compliance with MGR requirements, which include the receipt, handling, retrieval, and disposal of waste; periodic performance testing to verify preclosure requirements and to demonstrate safe and reliable MGR operation; and performance confirmation modeling, testing, and analysis to verify adherence to postclosure regulatory requirements. Development test activities can be

  13. A compliance testing program for diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Hutchinson, D.E.; Cobb, B.J.; Jacob, C.S.

    1999-01-01

    Compliance testing is nominally that part of a quality assurance program dealing with those aspects of X-ray equipment performance that are subject to radiation control legislation. Quality assurance programs for medical X-ray equipment should be an integral part of the quality culture in health care. However while major hospitals and individual medical centers may implement such programs with some diligence, much X-ray equipment can remain unappraised unless there is a comprehensive regulatory inspection program or some form of compulsion on the equipment owner to implement a testing program. Since the late 1950s all X-ray equipment in the State of Western Australia has been inspected by authorized officers acting on behalf of the Radiological Council, the regulatory authority responsible for administration of the State's Radiation Safety Act. However, economic constraints, coupled with increasing X-ray equipment numbers and a geographically large State have significantly affected the inspection rate. Data available from inspections demonstrate that regular compliance and performance checks are essential in order to ensure proper performance and to minimize unnecessary patient and operator dose. To ensure that diagnostic X-ray equipment complies with accepted standards and performance criteria, the regulatory authority introduced a compulsory compliance testing program for all medical, dental and chiropractic diagnostic X-ray equipment effective from 1 January 1997

  14. CFC and HFC recycling equipments: Test performances

    International Nuclear Information System (INIS)

    Picini, P.; Caropreso, G.; Cicoli, G.; Posarelli, M.

    1996-12-01

    Actual regulatory conditions about ozone layer depleting chemicals set problems on their disposal and on the management of plants still using illegal CFCs. Anyway fluids that will replace CFCs (i.e. HFCs) will not be allowed to be spread into the atmosphere, due to their high costs and to the greenhouse effect. A viable solution would be the recovery, purification and recycle of contaminated fluids. ENEA (National Agency for New Technology, Energy and the Environment), in cooperation with ICF (Industria Componenti Frigoriferi) Company leader in the field of air refrigerating and conditioning, patented a device able to extract, to clean and to recycle CFC 12 and HFC 134a in the refrigerating systems. This paper presents experimental data from the qualification tests on a device performing the above mentioned operations regarding systems that use HFC 134a as process fluid

  15. Shaking table testing of electrical equipment in Argentina

    International Nuclear Information System (INIS)

    Carmona, J.S.; Zabala, F.; Santalucia, J.; Sisterna, C.; Magrini, M.; Oldecop, L.

    1995-01-01

    This paper describes the testing facility, the methodology applied and the results obtained in the seismic qualification tests of different types of electric equipment. These tests were carried out on a shaking table that was developed and built at the Earthquake Research Institute of the National University of San Juan, Argentine. The equipment tested consist of 500 KV and 132 KV current transformers, a 500 KV voltage transformer, a 145 KV disconnecter and a relay cabinet. The acceleration response of the tested equipment was measured at several locations distributed along its height, and strains were measured at critical points by strain gauges cemented on the base of the porcelain insulator. All the information was recorded with a data acquisition system at a sampling rate of 200 times per second in each channel. The facility developed at this Institute is the largest one in operation in Argentina at present and the equipment tested is the highest, heaviest and more slender one which has been seismically qualified on a shaking table in this country. These tests have been a valuable experience in the field of structural dynamic testing applied to equipment of hydroelectric and nuclear power plants. (author)

  16. Development of a Test Equipment for Performance Evaluation of Safety Systems

    International Nuclear Information System (INIS)

    Kim, S. J.; Kwon, S. M.; Lee, J. M.; Kim, C. K.; Cho, C. H.; Chun, J. H.; Park, M. K.

    2004-07-01

    The purpose of this study is to develop a test equipment for performance evaluation of safety systems in nuclear power plants. First, we develop an input-output simulator for reactor protection systems, ESF component control systems, and a data acquisition system for these I/O simulators as a hardware for this equipment. Then, we develop a software for human-machine interface system, which is easy-to-use and easy-to-modify. In addition, a simulation tool for a reactor trip switch gear is developed

  17. Method and equipment for treating waste water resulting from the technological testing processes of NPP equipment

    International Nuclear Information System (INIS)

    Radulescu, M. C.; Valeca, S.; Iorga, C.

    2016-01-01

    Modern methods and technologies coupled together with advanced equipment for treating residual substances resulted from technological processes are mandatory measures for all industrial facilities. The correct management of the used working agents and of the all wastes resulted from the different technological process (preparation, use, collection, neutralization, discharge) is intended to reduce up to removal of their potential negative impact on the environment. The high pressure and temperature testing stands from INR intended for functional testing of nuclear components (fuel bundles, fuelling machines, etc.) were included in these measures since the use of oils, demineralized water chemically treated, greases, etc. This paper is focused on the method and equipment used at INR Pitesti in the chemical treatment of demineralized waters, as well as the equipment for collecting, neutralizing and discharging them after use. (authors)

  18. Point-of-Care Test Equipment for Flexible Laboratory Automation.

    Science.gov (United States)

    You, Won Suk; Park, Jae Jun; Jin, Sung Moon; Ryew, Sung Moo; Choi, Hyouk Ryeol

    2014-08-01

    Blood tests are some of the core clinical laboratory tests for diagnosing patients. In hospitals, an automated process called total laboratory automation, which relies on a set of sophisticated equipment, is normally adopted for blood tests. Noting that the total laboratory automation system typically requires a large footprint and significant amount of power, slim and easy-to-move blood test equipment is necessary for specific demands such as emergency departments or small-size local clinics. In this article, we present a point-of-care test system that can provide flexibility and portability with low cost. First, the system components, including a reagent tray, dispensing module, microfluidic disk rotor, and photometry scanner, and their functions are explained. Then, a scheduler algorithm to provide a point-of-care test platform with an efficient test schedule to reduce test time is introduced. Finally, the results of diagnostic tests are presented to evaluate the system. © 2014 Society for Laboratory Automation and Screening.

  19. Definition of common support equipment and space station interface requirements for IOC model technology experiments

    Science.gov (United States)

    Russell, Richard A.; Waiss, Richard D.

    1988-01-01

    A study was conducted to identify the common support equipment and Space Station interface requirements for the IOC (initial operating capabilities) model technology experiments. In particular, each principal investigator for the proposed model technology experiment was contacted and visited for technical understanding and support for the generation of the detailed technical backup data required for completion of this study. Based on the data generated, a strong case can be made for a dedicated technology experiment command and control work station consisting of a command keyboard, cathode ray tube, data processing and storage, and an alert/annunciator panel located in the pressurized laboratory.

  20. Interfacing the septa movement (DC motor) equipment to the PS control system and the MIL1553 bus

    CERN Document Server

    Dehavay, Claude

    1993-01-01

    Continuing the rejuvenation of the PS Control system , it is planned to replace the Single Transceiver Hybrid used to interface the Septa Movement Equipment by a G64 system connected to the VME crate via the MIL1553 bus. This note explains the G64 hardware interface and details the standard message as defined in the Control Protocole for Power Converter, RF and Stepping Motor equipment.

  1. Initial acceptance test experience with FFTF plant equipment

    International Nuclear Information System (INIS)

    Brown, R.K.; Coleman, K.A.; Mahaffey, M.K.; McCargar, C.G.; Young, M.W.

    1978-09-01

    The purpose of this paper is to examine the initial acceptance test experience of certain pieces of auxiliary equipment of the Fast Flux Test Facility (FFTF). The scope focuses on the DHX blowers and drive train, inert gas blowers, H and V containment isolation valves, and the Surveillance and In-service Inspection (SISI) transporter and trolley. For each type of equipment, the discussion includes a summary of the design and system function, installation history, preoperational acceptance testing procedures and results, and unusual events and resolutions

  2. Evolution of seismic shock test qualification of equipment

    International Nuclear Information System (INIS)

    Berriaud, C.

    1979-01-01

    From the first nuclear power plants a new industrial problem is appeared: the seismic test qualification of equipment. Nothing was existing in this range. Methods and test experiments were to be studied and perfected in order to obtain safe results. This paper presents the evolution of this question up to now [fr

  3. Equipment qualification testing methodology research at Sandia Laboratories

    International Nuclear Information System (INIS)

    Jeppesen, D.

    1983-01-01

    The Equipment Qualification Research Testing (EQRT) program is an evolutionary outgrowth of the Qualification Testing Evaluation (QTE) program at Sandia. The primary emphasis of the program has been qualification methodology research. The EQRT program offers to the industry a research-oriented perspective on qualification-related component performance, as well as refinements to component testing standards which are based upon actual component testing research

  4. Interfacing the septa movement (DC motors) equipment to the PS control system and the MIL1553 bus

    CERN Document Server

    Dehavay, Claude

    1995-01-01

    Continuing the rejuvenation of the PS Control system , this application replaces the Single Transceiver Hybrid used to interface the Septa Movement Fquipment by a G64 system connected to the VME crate via the MIL1553 bus. This note explains the G64 hardware interface and details the standard message as defined in the Control Protocole for Power Converter, RF and Stepping Motor equipment.

  5. High level radioactive waste vitrification process equipment component testing

    International Nuclear Information System (INIS)

    Siemens, D.H.; Heath, W.O.; Larson, D.E.; Craig, S.N.; Berger, D.N.; Goles, R.W.

    1985-04-01

    Remote operability and maintainability of vitrification equipment were assessed under shielded-cell conditions. The equipment tested will be applied to immobilize high-level and transuranic liquid waste slurries that resulted from plutonium production for defense weapons. Equipment tested included: a turntable for handling waste canisters under the melter; a removable discharge cone in the melter overflow section; a thermocouple jumper that extends into a shielded cell; remote instrument and electrical connectors; remote, mechanical, and heat transfer aspects of the melter glass overflow section; a reamer to clean out plugged nozzles in the melter top; a closed circuit camera to view the melter interior; and a device to retrieve samples of the glass product. A test was also conducted to evaluate liquid metals for use in a liquid metal sealing system

  6. Reliability performance of standby equipment with periodic testing

    International Nuclear Information System (INIS)

    Sim, S.H.

    1985-11-01

    In this report, the reliability performance of standby equipment subjected to periodic testing is studied. analytical expressions have been derived for reliability measures, such as the man accumulated operating time to failure, the expected number of tests between two consecutive failures, the mean time to failure following an emergency start-up and the probability of failing to complete an emergency mission of a specified duration. These results are useful for the reliability assessment of standby equipment such as combustion turbine units of the emergency power supply system, and of the Class III power system at a nuclear generating station

  7. Diagnosis - Using automatic test equipment and artificial intelligence expert systems

    Science.gov (United States)

    Ramsey, J. E., Jr.

    Three expert systems (ATEOPS, ATEFEXPERS, and ATEFATLAS), which were created to direct automatic test equipment (ATE), are reviewed. The purpose of the project was to develop an expert system to troubleshoot the converter-programmer power supply card for the F-15 aircraft and have that expert system direct the automatic test equipment. Each expert system uses a different knowledge base or inference engine, basing the testing on the circuit schematic, test requirements document, or ATLAS code. Implementing generalized modules allows the expert systems to be used for any different unit under test. Using converted ATLAS to LISP code allows the expert system to direct any ATE using ATLAS. The constraint propagated frame system allows for the expansion of control by creating the ATLAS code, checking the code for good software engineering techniques, directing the ATE, and changing the test sequence as needed (planning).

  8. Ballooning test equipment for use in hot cells

    International Nuclear Information System (INIS)

    Broendsted, P.; Adrian, F.

    1979-12-01

    An equipment for testing the LOCA behaviour of irradiated cladding materials is described. The details of the construction and of the installation in the Hot Cells are reported. Pilot tests carried out showed that the performance of the system fulfills the basic experimental prerequisites, which were: heating rate of 2-3degC/s, final temperature 1150degC/s, internal pressure max. 30 atm, external pressure max. 1 atm, test atmosphere either air or steam. (author)

  9. Diagnostic x-ray equipment compliance and facility survey. Recommended procedures for equipment and facility testing

    International Nuclear Information System (INIS)

    1994-01-01

    The Radiation Protection Bureau has set out guidelines for the testing of diagnostic x-ray equipment and facilities. This guide provides information for the x-ray inspector, test engineer, technologist, medical physicist and any other person responsible for verifying the regulatory compliance or safety of diagnostic x-ray equipment and facilities. Diagnostic x-radiation is an essential part of present day medical practice. The largest contributor of irradiation to the general population comes from diagnostic x-radiation. Although individual irradiations are usually small, there is a concern of possible excess cancer risk when large populations are irradiated. Unnecessary irradiations to patients from radiological procedures can be significantly reduced with little or no decrease in the value of medical diagnostic information. This can be achieved by using well designed x-ray equipment which is installed, used and maintained by trained personnel, and by the adoption of standardized procedures. In general, when patient surface dose is reduced, there is a corresponding decrease in dose to x-ray equipment operators and other health care personnel. 2 tabs., 4 figs

  10. Diagnostic x-ray equipment compliance and facility survey. Recommended procedures for equipment and facility testing

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-12-31

    The Radiation Protection Bureau has set out guidelines for the testing of diagnostic x-ray equipment and facilities. This guide provides information for the x-ray inspector, test engineer, technologist, medical physicist and any other person responsible for verifying the regulatory compliance or safety of diagnostic x-ray equipment and facilities. Diagnostic x-radiation is an essential part of present day medical practice. The largest contributor of irradiation to the general population comes from diagnostic x-radiation. Although individual irradiations are usually small, there is a concern of possible excess cancer risk when large populations are irradiated. Unnecessary irradiations to patients from radiological procedures can be significantly reduced with little or no decrease in the value of medical diagnostic information. This can be achieved by using well designed x-ray equipment which is installed, used and maintained by trained personnel, and by the adoption of standardized procedures. In general, when patient surface dose is reduced, there is a corresponding decrease in dose to x-ray equipment operators and other health care personnel. 2 tabs., 4 figs.

  11. Inflatable Module Seal Interface Development and Testing

    Data.gov (United States)

    National Aeronautics and Space Administration — Develop a repeatable low permeable sealing interface evaluating O-ring, RTV bond and flowed RTV bond methods. Advanced Bladder materials (ArmorFlex, Nanoclay, etc)...

  12. Reliability and maintainability data acquisition in equipment development tests

    International Nuclear Information System (INIS)

    Haire, M.J.; Gift, E.H.

    1983-10-01

    The need for collection of reliability, maintainability, and availability data adds a new dimension to the data acquisition requirements of equipment development tests. This report describes the reliability and maintainability data that are considered necessary to ensure that sufficient and high quality data exist for a comprehensive, quantitative evaluation of equipment and system availability. These necessary data are presented as a set of data collection forms. Three data acquisition forms are discussed: an inventory and technical data form, which is filed by the design engineer when the design is finished or the equipment is received; an event report form, which is completed by the senior test operator at each shutdown; and a maintainability report, which is a collaborative effort between senior operators and lead engineers and is completed on restart. In addition, elements of a reliability, maintainability evaluation program are described. Emphasis is placed on the role of data, its storage, and use in such a program

  13. Evaluation of field test equipment for halide and DOP testing

    International Nuclear Information System (INIS)

    Schreiber, K.L.; Kovach, J.L.

    1975-01-01

    The Nucon Testing Services Department, field testing at power reactor sites, has performed tests using R-11, R-12, and R-112 in conjunction with gas chromatographs and direct reading halide detectors. The field operational experience with these detector systems, thus sensitivity, precision, and manner of field calibration, are presented. Laboratory experiments regarding 3 H-tagged methyl iodide for in place leak testing of adsorber systems indicate a low hazard, high reliability process for leak testing in facilities where atmospheric cross contamination occurs. (U.S.)

  14. Dynamic tension testing equipment for paperboard and corrugated fiberboard

    Science.gov (United States)

    W. D. Godshall

    1965-01-01

    The objective of this work was to develop a method, the testing equipment, and the instrumentation with which dynamic stress-strain information may be obtained for paperboards and built-up corrugated fiberboards as used in corrugated fiberboard containers. Much information is available on the properties of these materials when subjected to static or low rates of...

  15. Project W320 52-inch diameter equipment container load test: Test report

    International Nuclear Information System (INIS)

    Bellomy, J.R.

    1995-01-01

    This test report summarizes testing activities and documents the results of the load tests performed on-site and off-site to structural qualify the 52-inch equipment containers designed and fabricated under Project W-320

  16. Test cases for interface tracking methods: methodology and current status

    International Nuclear Information System (INIS)

    Lebaigue, O.; Jamet, D.; Lemonnier, E.

    2004-01-01

    Full text of publication follows:In the past decade, a large number of new methods have been developed to deal with interfaces in the numerical simulation of two-phase flows. We have collected a set of 36 test cases, which can be seen as a tool to help engineers and researchers selecting the most appropriate method(s) for their specific fields of application. This set can be use: - To perform an initial evaluation of the capabilities of available methods with regard to the specificity of the final application and the most important features to be recovered from the simulation. - To measure the maximum mesh size to be used for a given physical problem in order to obtain an accurate enough solution. - To assess and quantify the performances of a selected method equipped with its set of physical models. The computation of a well-documented test case allows estimating the error due to the numerical technique by comparison with reference solutions. This process is compulsory to gain confidence and credibility on the prediction capabilities of a numerical method and its physical models. - To broaden the capabilities of a given numerical technique. The test cases may be used to identify the need for improvement of the overall numerical scheme or to determine the physical part of the model, which is responsible for the observed limitations. Each test case falls within one of the following categories: - Analytical solutions of well-known sets of equations corresponding to simple geometrical situations. - Reference numerical solutions of moderately complex problems, produced by accurate methods (e.g., boundary Fitted coordinate method) on refined meshes. - Separate effects analytical experiments. The presentation will suggest how to use the test cases for assessing the physical models and the numerical methods. The expected fallout of using test cases is indeed on the one hand to identify the merits of existing methods and on the other hand to orient further research towards

  17. Development of automatic ultrasonic testing equipment for reactor pressure vessel

    International Nuclear Information System (INIS)

    Jang, Kee Ok; Park, Dae Yung; Park, Moon Hoh; Koo, Kil Mo; Park, Kwang Heui; Kang, Sang Sin; Bang, Heui Song; Noh, Heui Choong; Kong, Woon Sik

    1994-08-01

    The selected weld areas of reactor pressure vessel and adjacent piping are examined by remote mechanized ultrasonic testing(MUT) equipment. Since the MUT equipment was purchased from Southwest Research Institute (SwRI) in April 1985, we have performed 15 inservice inspections and 5 preservice inspections. However, the reliability of examination was recently decreased rapidly as the problems which results from the old age of equipment and the frequent movement to plant site to site have occurred frequently. Therefore, the 3-axis control system hardware in occurring many problems among the equipments of mechanized ultrasonic testing (MUT) was designed and developed to cover the examination areas of nozzle-shell weld as specified in ASME Code Section XI and to improve the examination reliability. The new 3-axis control system hardware with the performance of this project was developed to be compatible with the old one and it was used as dual system or spare parts of the old system. Furthermore, the established technologies are expected to be applied to the similar control systems in nuclear power plant. 17 figs, 2 pix, 2 tabs, 10 refs. (Author)

  18. Development of automatic ultrasonic testing equipment for reactor pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Jang, Kee Ok; Park, Dae Yung; Park, Moon Hoh; Koo, Kil Mo; Park, Kwang Heui; Kang, Sang Sin; Bang, Heui Song; Noh, Heui Choong; Kong, Woon Sik [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-08-01

    The selected weld areas of reactor pressure vessel and adjacent piping are examined by remote mechanized ultrasonic testing(MUT) equipment. Since the MUT equipment was purchased from Southwest Research Institute (SwRI) in April 1985, we have performed 15 inservice inspections and 5 preservice inspections. However, the reliability of examination was recently decreased rapidly as the problems which results from the old age of equipment and the frequent movement to plant site to site have occurred frequently. Therefore, the 3-axis control system hardware in occurring many problems among the equipments of mechanized ultrasonic testing (MUT) was designed and developed to cover the examination areas of nozzle-shell weld as specified in ASME Code Section XI and to improve the examination reliability. The new 3-axis control system hardware with the performance of this project was developed to be compatible with the old one and it was used as dual system or spare parts of the old system. Furthermore, the established technologies are expected to be applied to the similar control systems in nuclear power plant. 17 figs, 2 pix, 2 tabs, 10 refs. (Author).

  19. Automatic test equipment for C and I of compact LWR

    International Nuclear Information System (INIS)

    Mayya, Anuradha; Marathe, P.P.; Madala, Kalyan C.

    2014-01-01

    The C and I of compact LWR consist of a wide variety of electronic modules. Testing of these modules manually was found to be very cumbersome. To ease the testing of these modules, Automatic Test Equipments (ATE) were developed jointly by BARC and ECIL. This paper describes the design of two ATEs for testing 69 types of modules. A power supply ATE was developed for 43 types of power supply modules of type AC-AC, AC-DC, DC-DC and signal conditioning modules. A VME ATE was developed to test 26 types of VME bus based and other microcontroller based non-bussed modules. These ATEs are used for the automated black box testing of modules by feeding power and control inputs and checking the outputs without operator intervention. This paper describes the important considerations in design and the major design challenges. (author)

  20. An equipment test for grading lumber by transverse vibration technique

    Directory of Open Access Journals (Sweden)

    Marcelo Rodrigo Carreira

    2008-08-01

    Full Text Available Due to the great variability of its mechanical properties, the rational use of lumber for structural purposes is directly conditioned to its grading. There are several techniques available for grading structural lumber. The most relevant one is the transverse vibration technique which obtained reliable results in non-destructive evaluation of lumber. The purpose of this work is to present the bases for the mechanical grading of lumber and the results of the calibration test of the frst transverse vibration equipment developed in Brazil. In this research 30 beams of cupiúba (Goupia glabra with nominal dimensions of 5 cm X 10 cm X 300 cm, were used. The tests were accomplished at the Wood and Timber Structures Laboratory (LaMEM of the University of São Paulo (USP. The results showed a strong correlation between the elasticity modulus measured by the static bending test and the one obtained with the transverse vibration equipment, showing the high reliability of the vibration method for the grading of structural lumber. A determination coeffcient (R² of 0.896 was obtained with the Brazilian equipment, showing that it can be used in the grading of lumber.

  1. Development of automatic Ultrasonic testing equipment for reactor pressure vessel

    International Nuclear Information System (INIS)

    Kim, Kor R.; Kim, Jae H.; Lee, Jae C.

    1996-06-01

    The selected weld areas of a reactor pressure vessel and adjacent piping are examined by the remote mechanized ultrasonic testing (MUT) equipment. Since the MUT equipment was purchased from southwest Research Institute (SwRI) in April 1985, 15 inservice inspections and 5 preservice inspections are performed with this MUT equipment. However due to the old age of the equipment and frequent movements to plant sites, the reliability of examination was recently decreased rapidly and it is very difficult to keep spare parts. In order to resolve these problems and to meet the strong request from plant sites, we intend to develop a new 3-axis control system including hardware and software. With this control system, we expect more efficient and reliable examination of the nozzle to shell weld areas, which is specified in ASME Code Section XI. The new 3-axis control system hardware and software were designed and development of our own control system, the advanced technologies of computer control mechanism were established and examination reliability of the nozzle to shell weld area was improved. With the development of our 3-axis control system for PaR ISI-2 computer control system, the reliability of nozzle to shell weld area examination has been improved. The established technologies from the development and detailed analysis of existing control system, are expected to be applied to the similar control systems in nuclear power plants. (author). 12 refs., 4 tabs., 33 figs

  2. Development of automatic Ultrasonic testing equipment for reactor pressure vessel

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kor R.; Kim, Jae H.; Lee, Jae C.

    1996-06-01

    The selected weld areas of a reactor pressure vessel and adjacent piping are examined by the remote mechanized ultrasonic testing (MUT) equipment. Since the MUT equipment was purchased from southwest Research Institute (SwRI) in April 1985, 15 inservice inspections and 5 preservice inspections are performed with this MUT equipment. However due to the old age of the equipment and frequent movements to plant sites, the reliability of examination was recently decreased rapidly and it is very difficult to keep spare parts. In order to resolve these problems and to meet the strong request from plant sites, we intend to develop a new 3-axis control system including hardware and software. With this control system, we expect more efficient and reliable examination of the nozzle to shell weld areas, which is specified in ASME Code Section XI. The new 3-axis control system hardware and software were designed and development of our own control system, the advanced technologies of computer control mechanism were established and examination reliability of the nozzle to shell weld area was improved. With the development of our 3-axis control system for PaR ISI-2 computer control system, the reliability of nozzle to shell weld area examination has been improved. The established technologies from the development and detailed analysis of existing control system, are expected to be applied to the similar control systems in nuclear power plants. (author). 12 refs., 4 tabs., 33 figs.

  3. Specification and acceptance testing of nuclear medicine equipment

    International Nuclear Information System (INIS)

    Wegst, A.V.; Erickson, J.J.

    1984-01-01

    The purchase of nuclear medicine equipment is of prime importance in the operation of a clinical service. Failure to properly evaluate the potential uses of the instrumentation and the various operational characteristics of the equipment can often result in the purchase of inappropriate or inferior instruments. The magnitude of the purchase in terms of time and financial investments make it imperative that the purchase be approached in a systematic manner. Consideration of both the intended clinical functions and personnel requirements is important. It is necessary also to evaluate the ability of the equipment vendor to support the instrumentation after the purchase has been completed and the equipment installed in the clinical site. The desired specifications of the instrument characteristics should be stated in terms that can be verified by acceptance testing. The complexity of modern instrumentation and the sensitivity of it to the environment require the buyer to take into account the potential problems of controlling the temperature, humidity, and electrical power of the installation site. If properly and systematically approached, the purchase of new nuclear medicine instrumentation can result in the acquisition of a powerful diagnostic tool which will have a useful lifetime of many years. If not so approached, it may result in the expenditure of a large amount of money and personnel time without the concomitant return in useful clinical service. (author)

  4. Test method to assess interface adhesion in composite bonding

    NARCIS (Netherlands)

    Teixeira de Freitas, S.; Sinke, J.

    2015-01-01

    This paper introduces a new type of peel tests dedicated to composite bonding: Composite Peel Tests. This test is inspired on the standard floating roller peel test widely used for metal bonding. The aim of this study is to investigate the potential of the Composite Peel Test to assess interface

  5. TMACS Test Procedure TP008: SACS Interface. Revision 5

    International Nuclear Information System (INIS)

    Washburn, S.J.

    1994-01-01

    The TMACS Software Project Test Procedures translate the project's acceptance criteria into test steps. Software releases are certified when the affected Test Procedures are successfully performed and the customers authorize installation of these changes. This Test Procedure tests the TMACS SACS Interface functions

  6. Tests of the Royce ultrasonic interface level analyzer

    International Nuclear Information System (INIS)

    WITWER, K.S.

    1999-01-01

    This document describes testing carried out in 1995 on the Royce Interface Level Analyzer. The testing was carried out in the 305 Bldg., Engineering Testing Laboratory, 300 Area. The Level Analyzer was shown to be able to effectively locate the solid liquid interface layer of two different simulants under various conditions and was able to do so after being irradiated with over 5 million RADS gamma from a Cobalt 60 source

  7. Bidirectional converter interface for a battery energy storage test bench

    DEFF Research Database (Denmark)

    Trintis, Ionut; Thomas, Stephan; Blank, Tobias

    2011-01-01

    This paper presents the bidirectional converter interface for a 6 kV battery energy storage test bench. The power electronic interface consists a two stage converter topology having a low voltage dc-ac grid connected converter and a new dual active bridge dc-dc converter with high transformation...

  8. Technical baseline description for in situ vitrification laboratory test equipment

    International Nuclear Information System (INIS)

    Beard, K.V.; Bonnenberg, R.W.; Watson, L.R.

    1991-09-01

    IN situ vitrification (ISV) has been identified as possible waste treatment technology. ISV was developed by Pacific Northwest Laboratory (PNL), Richland, Washington, as a thermal treatment process to treat contaminated soils in place. The process, which electrically melts and dissolves soils and associated inorganic materials, simultaneously destroys and/or removes organic contaminants while incorporating inorganic contaminants into a stable, glass-like residual product. This Technical Baseline Description has been prepared to provide high level descriptions of the design of the Laboratory Test model, including all design modifications and safety improvements made to data. Furthermore, the Technical Baseline Description provides a basic overview of the interface documents for configuration management, program management interfaces, safety, quality, and security requirements. 8 figs

  9. Development of ultrasonic testing equipment incorporating electromagnetic acoustic transducer

    International Nuclear Information System (INIS)

    Sato, Michio; Kimura, Motohiko; Okano, Hideharu; Miyazawa, Tatsuo; Nagase, Koichi; Ishikawa, Masaaki

    1989-01-01

    An ultrasonic testing equipment for use in in-service inspection of nuclear power plant piping has been developed, which comprises an angle-beam electromagnetic acoustic transducer mounted on a vehicle for scanning the piping surface to be inspected. The transducer functions without direct contact with the piping surface through couplant, and the vehicle does not require a guide track installed on the piping surface, being equipped with magnetic wheels that adhere to the piping material, permitting it to travel along the circumferential weld joint of a carbon steel pipe. The equipment thus dispenses with the laborious manual work involved in preparing the piping for inspection, such as removal of protective coating, surface polishing and installation of guide track and thereby considerably reduces the duration of inspection. The functioning principle and structural features of the transducer and vehicle are described, together with the results of trial operation of a prototype unit, which proved a 1mm deep notch cut on a test piece of 25mm thick carbon steel plate to be locatable with an accuracy of ±2mm. (author)

  10. Organization of a joint operation of PC and CAMAC equipment using KK106 crate controller and MULTI interface

    International Nuclear Information System (INIS)

    Vagov, V.A.; Sirotin, A.P.; Tulaev, A.B.; Tumanov, A.V.

    1989-01-01

    Hardware and software which permit to provide a joint operation of IBM PC/XT/AT (or compatibles) with CAMAC equipment are described. Wide-spread in the JINR the 106 type interface is used as CAMAC Dataway controller and MULTI interface is used as PC-Bus adapter. MULTI additional on-board module Baby-106 that emulates cut-down UNIBUS for 106 type interface is designed. The means offered allow PC and CAMAC modules to operate jointly both via the program transfer channel and DMA channel. Maximum (hardware) performance is obtained in DMA case. 5 refs.; 1 fig

  11. Remote maintenance systems requirements are being developed to provide design guidelines for machine components, to define maintenance interfaces, and to quantify maintenance equipment and procedures needed

    International Nuclear Information System (INIS)

    Spampinato, P.T.; Tabor, M.A.

    1988-01-01

    Remote maintenance systems requirements are being developed to provide design guidelines for machine components, to define maintenance interfaces, and to quantify maintenance equipment and procedures needed

  12. Comparative tests of bench equipment for fuel control system testing of gas-turbine engine

    Science.gov (United States)

    Shendaleva, E. V.

    2018-04-01

    The relevance of interlaboratory comparative researches is confirmed by attention of world metrological community to this field of activity. Use of the interlaboratory comparative research methodology not only for single gages collation, but also for bench equipment complexes, such as modeling stands for fuel control system testing of gas-turbine engine, is offered. In this case a comparative measure of different bench equipment will be the control fuel pump. Ensuring traceability of measuring result received at test benches of various air enterprises, development and introduction of national standards to practice of bench tests and, eventually, improvement of quality and safety of a aircraft equipment is result of this approach.

  13. High Temperature Calcination - MACT Upgrade Equipment Pilot Plant Test

    Energy Technology Data Exchange (ETDEWEB)

    Richard D. Boardman; B. H. O& #39; Brien; N. R. Soelberg; S. O. Bates; R. A. Wood; C. St. Michel

    2004-02-01

    About one million gallons of acidic, hazardous, and radioactive sodium-bearing waste are stored in stainless steel tanks at the Idaho Nuclear Technology and Engineering Center (INTEC), which is a major operating facility of the Idaho National Engineering and Environmental Laboratory. Calcination at high-temperature conditions (600 C, with alumina nitrate and calcium nitrate chemical addition to the feed) is one of four options currently being considered by the Department of Energy for treatment of the remaining tank wastes. If calcination is selected for future processing of the sodium-bearing waste, it will be necessary to install new off-gas control equipment in the New Waste Calcining Facility (NWCF) to comply with the Maximum Achievable Control Technology (MACT) standards for hazardous waste combustors and incinerators. This will require, as a minimum, installing a carbon bed to reduce mercury emissions from their current level of up to 7,500 to <45 {micro}g/dscm, and a staged combustor to reduce unburned kerosene fuel in the off-gas discharge to <100 ppm CO and <10 ppm hydrocarbons. The staged combustor will also reduce NOx concentrations of about 35,000 ppm by 90-95%. A pilot-plant calcination test was completed in a newly constructed 15-cm diameter calciner vessel. The pilot-plant facility was equipped with a prototype MACT off-gas control system, including a highly efficient cyclone separator and off-gas quench/venturi scrubber for particulate removal, a staged combustor for unburned hydrocarbon and NOx destruction, and a packed activated carbon bed for mercury removal and residual chloride capture. Pilot-plant testing was performed during a 50-hour system operability test January 14-16, followed by a 100-hour high-temperature calcination pilot-plant calcination run January 19-23. Two flowsheet blends were tested: a 50-hour test with an aluminum-to-alkali metal molar ratio (AAR) of 2.25, and a 50-hour test with an AAR of 1.75. Results of the testing

  14. Development report: Automatic System Test and Calibration (ASTAC) equipment

    Science.gov (United States)

    Thoren, R. J.

    1981-01-01

    A microcomputer based automatic test system was developed for the daily performance monitoring of wind energy system time domain (WEST) analyzer. The test system consists of a microprocessor based controller and hybrid interface unit which are used for inputing prescribed test signals into all WEST subsystems and for monitoring WEST responses to these signals. Performance is compared to theoretically correct performance levels calculated off line on a large general purpose digital computer. Results are displayed on a cathode ray tube or are available from a line printer. Excessive drift and/or lack of repeatability of the high speed analog sections within WEST is easily detected and the malfunctioning hardware identified using this system.

  15. Equipment design for reliability testing of protection system

    International Nuclear Information System (INIS)

    Situmorang, Johnny; Tjahjono, H.; Santosa, A. Z.; Tjahjani, S.DT.; Ismu, P.H; Haryanto, D.; Mulyanto, D.; Kusmono, S

    1999-01-01

    The equipment for reliability testing of cable of protection system has been designed as a a furnace with the electric heater have a 4 kW power, and need time 10 minute to reach the designed maximum temperature 3000C. The dimension of furnace is 800 mm diameter and 2000 mm length is isolated use rockwool isolator and coated by aluminium. For the designed maximum temperature the surface temperature is 78 0c. Assemble of specimens is arranged horizontally in the furnace. The failure criteria will be defined based on the behaviour of the load circuit in each line of cable specimens

  16. Comparison of Automated Graphical User Interface Testing Tools

    OpenAIRE

    Gaber, Domen

    2018-01-01

    The thesis presents the analysis of modern tools for automated testing of various web based user interfaces. The purpose of the work is to compare specific test automation solutions and point out the most suitable test automation tool amongst them. One of the main goals of test automation is to gain faster execution when compared to manual testing and overall cost deduction. There are multiple test automation solutions available on the market, which differ in complexity of use, type of o...

  17. Helping Students Test Programs That Have Graphical User Interfaces

    Directory of Open Access Journals (Sweden)

    Matthew Thornton

    2008-08-01

    Full Text Available Within computer science education, many educators are incorporating software testing activities into regular programming assignments. Tools like JUnit and its relatives make software testing tasks much easier, bringing them into the realm of even introductory students. At the same time, many introductory programming courses are now including graphical interfaces as part of student assignments to improve student interest and engagement. Unfortunately, writing software tests for programs that have significant graphical user interfaces is beyond the skills of typical students (and many educators. This paper presents initial work at combining educationally oriented and open-source tools to create an infrastructure for writing tests for Java programs that have graphical user interfaces. Critically, these tools are intended to be appropriate for introductory (CS1/CS2 student use, and to dovetail with current teaching approaches that incorporate software testing in programming assignments. We also include in our findings our proposed approach to evaluating our techniques.

  18. Validation Testing for Automated Solubility Measurement Equipment Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Lachut, J. S. [Washington River Protection Solutions LLC, Richland, WA (United States)

    2016-01-11

    Laboratory tests have been completed to test the validity of automated solubility measurement equipment using sodium nitrate and sodium chloride solutions (see test plan WRPS-1404441, “Validation Testing for Automated Solubility Measurement Equipment”). The sodium nitrate solution results were within 2-3% of the reference values, so the experiment is considered successful using the turbidity meter. The sodium chloride test was done by sight, as the turbidity meter did not work well using sodium chloride. For example, the “clear” turbidity reading was 53 FNU at 80 °C, 107 FNU at 55 °C, and 151 FNU at 20 °C. The sodium chloride did not work because it is granular and large; as the solution was stirred, the granules stayed to the outside of the reactor and just above the stir bar level, having little impact on the turbidity meter readings as the meter was aimed at the center of the solution. Also, the turbidity meter depth has an impact. The salt tends to remain near the stir bar level. If the meter is deeper in the slurry, it will read higher turbidity, and if the meter is raised higher in the slurry, it will read lower turbidity (possibly near zero) because it reads the “clear” part of the slurry. The sodium chloride solution results, as measured by sight rather than by turbidity instrument readings, were within 5-6% of the reference values.

  19. The development of synthetic test procedure for hot cell equipment systems in IMEF

    International Nuclear Information System (INIS)

    Ahn, Sang Bok; Lee, Key Soon; Park, Dae Kyu; Hong, Kwon Pyo; Choo, Yong Sun

    1998-04-01

    Hot cell facility should be confirmed to operation safety through pre-commissioning test after construction. In this report, the detailed procedure of hot cell equipment are described. The contents are as follows: 1. Entrance equipment of hot cell 2. Specimen transportation equipment between hot cells 3. Waste discharge equipment in hot cell 4. Specimen loading equipment to hot cell 5. Interlinking equipment in hot cell. (author). 4 tabs

  20. SpaceWire: IP, Components, Development Support and Test Equipment

    Science.gov (United States)

    Parkes, S.; McClements, C.; Mills, S.; Martin, I.

    SpaceWire is a communications network for use onboard spacecraft. It is designed to connect high data-rate sensors, large solid-state memories, processing units and the downlink telemetry subsystem providing an integrated data-handling network. SpaceWire links are serial, high-speed (2 Mbits/sec to 400 Mbits/sec), bi-directional, full-duplex, pointto- point data links which connect together SpaceWire equipment. Application information is sent along a SpaceWire link in discrete packets. Control and time information can also be sent along SpaceWire links. SpaceWire is defined in the ECSS-E50-12A standard [1]. With the adoption of SpaceWire on many space missions the ready availability of intellectual property (IP) cores, components, software drivers, development support, and test equipment becomes a major issue for those developing satellites and their electronic subsystems. This paper describes the work being done at the University of Dundee and STAR-Dundee Ltd with ESA, BNSC and internal funding to make these essential items available. STAR-Dundee is a spin-out company of the University of Dundee set up specifically to support users of SpaceWire.

  1. Administration Interface in an e-Testing Software Platform

    Directory of Open Access Journals (Sweden)

    Diana BUTUCEA

    2011-09-01

    Full Text Available Administration interfaces represent a subject that requires an in-depth analysis. Due to the complex tasks it needs to execute, the developer of such interfaces must find a perfect balance between aesthetics, functionality, ergonomics and modularity of it. While web users become more and more selective into choosing the websites they browse, the interface of any application must be impeccable. Since e-testing software platforms require a complex content management system, the paper will provide arguments over functionality, aesthetics, ergonomics and modularity of such platforms. An in-depth comparison over four CMSs will be made and a model of implementation will also be presented focusing on the administration interface and the functionalities it offers.

  2. Measuring and test equipment control through bar-code technology

    International Nuclear Information System (INIS)

    Crockett, J.D.; Carr, C.C.

    1993-01-01

    Over the past several years, the use, tracking, and documentation of measuring and test equipment (M ampersand TE) has become a major issue. New regulations are forcing companies to develop new policies for providing use history, traceability, and accountability of M ampersand TE. This paper discusses how the Fast Flux Test Facility (FFTF), operated by Westinghouse Hanford Company and located at the Hanford site in Rich- land, Washington, overcame these obstacles by using a computerized system exercising bar-code technology. A data base was developed to identify M ampersand TE containing 33 separate fields, such as manufacturer, model, range, bar-code number, and other pertinent information. A bar-code label was attached to each piece of M ampersand TE. A second data base was created to identify the employee using the M ampersand TE. The fields contained pertinent user information such as name, location, and payroll number. Each employee's payroll number was bar coded and attached to the back of their identification badge. A computer program was developed to automate certain tasks previously performed and tracked by hand. Bar-code technology was combined with this computer program to control the input and distribution of information, eliminate common mistakes, electronically store information, and reduce the time required to check out the M ampersand TE for use

  3. Meteorological testing and analysis of sampling equipment for wet deposition

    International Nuclear Information System (INIS)

    Winkler, P.; Jobst, S.; Harder, C.

    1989-01-01

    11 rain collector types for wet deposition were subjected to a field test. Two of the nine types were identically constructed. The following measured values were analyzed: amount of rainfall, electrical conductivity, pH value, Cl - , NO 3 - , SO 4 = , NH 4 + , Na + , K + , Ca ++ , Mg ++ , Fe, Pb, Cu, Cd. The analysis was restricted to rainfall. In a basic study structural and statistical analyses of precipitations were made in order to find out from which extent of intensity resp. rain volume per rainfall the precipitations are important for wet deposition. Some sensors required intensities of nearly 1 mm/h in order to recognize all rainfalls. In order to reach a better standardization of the measuring technique the funnel geometry should be standardized. The current technique is not suited for correctly registering the deposition which is connected with light and very light rainfall. It was found out in rinsing tests with diluted HNO 3 that considerable amounts of trace metals accumulate at funnel walls and in headers, although the collecting device had been subjected to a thorough acid purification before. For the determination of the wet deposition of the trace metals problems arise if the samples are filtered and the filters are not analyzed. In that case particle-bound metals which are suspended in raindrops will not be registered. After comparing the equipment some of the devices were improved in order to eliminate known sources of contamination. (orig./KW) [de

  4. Field vibration test of principal equipment of nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Shiraki, Kazuhiro; Fujita, Katsuhisa; Kajimura, Motohiko; Ikegami, Yasuhiko; Hanzawa, Katsumi; Sakai, Yoshiyuki; Kokubo, Eiji; Igarashi, Shigeru

    1984-09-01

    Japan is one of the most earthquake-stricken countries in the world, and demands for aseismic design have become severer recently. In a nuclear power plant in particular, consisting of a reactor vessel and other facilities dealing with a radioactive substance in some form or other, it is essential from the standpoint of safety to eliminate any possibility of radioactive hazards for the local public, and the employees at the plant as well, if these facilities are struck by an earthquake. This paper is related to the reactor vessel, reactor primary cooling equipment and piping system and important general piping as examples of important facilities of a nuclear power plant, and discusses vibration tests of an actual plant in the field from the standpoint of enhancing the aseismic safety of the Mitsubishi PWR nuclear power plant. Especially concerning vibration test technology, the effects in the evaluation of aseismic safety and its limits are studied to prove how it contributes to the enhancement of the reliability of aseismic design of nuclear power plants.

  5. Design, analysis, and test of an active tubular interface

    Science.gov (United States)

    Elspass, Wilfried J.; Eerme, M.; Paradies, R.; Resch, Martin

    1997-06-01

    Space missions require higher and higher performance such as high pointing accuracy and stability, and high shape precision. Passive damping means often cannot fulfill the requirements. Besides space applications at the same time numerous applications in machine design require higher accuracy. For a lot of applications the passive measures come up against limits. Active technologies have to be considered more often. Active mechanical components are more and more used as a necessary step towards adaptive structures. Active mechanical interfaces are simpler systems having very useful applications and can be used as kind of test benches in order to master the most exacting technologies. The main advantages of such an active interface are the following: (1) state-of- the-art sensors and actuators can be used, (2) the mechanical design of the interface is conventional, (3) the passive behavior of the system is not deteriorated, (4) the design is compact and rather easy to integrate, (5) easy repair (replacement) of the active mechanical part, (6) standardization of the interfaces results in cost reductions. An important property in such intermediate step is that no major redesign of the conventionally designed mechanical structure should be needed. The design, numerical analysis, manufacturing and test of a fully integrated active tubular interface (ATI) is presented. The design of the ATI includes the optimal laminate stacking sequence with respect to maximum deformation efficiency. The results of an active damping application, an antenna support beam, including the controller layout are discussed.

  6. AIChe equipment testing procedure centrifugal compressors : a guide to performance evaluation and site testing

    CERN Document Server

    AIChE

    2013-01-01

    With its engineer-tested procedures and thorough explanations, Centrifugal Compressors is an essential text for anyone engaged in implementing new technology in equipment design, identifying process problems, and optimizing equipment performance.  This condensed book presents a step by step approach to preparing for, planning, executing, and analyzing tests of centrifugal compressors, with an emphasis on methods that can be conducted on-site and with an acknowledgement of the strengths and limitations of these methods. The book opens with an extensive and detailed section offering definitions

  7. The operator interface for the Mirror Fusion Test Facility

    International Nuclear Information System (INIS)

    Lang, N.C.

    1986-12-01

    The uncertain and most likely changing nature of a large experimental facility like MFTF, as well as its large number of control and monitor points, ruled against the traditional hardware approach involving walls of knobs, dials, oscilloscopes, and strip chart recorders. Rather, from the beginning, project management specified computer control of all systems, and operation of the complete MFTF under an integrated computer control system became a major engineering goal. The Integrated Controls and Diagnostics (ICADS) group was charged with the design and implementation of this control system. We designed a control system with an extremely flexible operator interface which uses computer generated CRT displays for output and pointing devices such as touch sensitive CRT overlays, mice, and joysticks for input. Construction of MFTF was completed at the end of 1985 within the project budget of $241.6M and was followed immediately by a 5 month long acceptance test. During this period (known as PACE test) operators, engineers, and physicists successfully used our computer control system daily to test MFTF. Much of their willingness to forsake the traditional hands-on hardware approach to testing was a result of the powerful and flexible operator interface to the MFTF control system. In this paper, we describe the operator interface with emphasis on the displays, the touch screens, and the mouse. We also report the experiences of users and, in particular, stress those aspects of the user interface they strongly liked and disliked

  8. Non-destructive testing: magnetizing equipment for magnetic particle inspection

    International Nuclear Information System (INIS)

    1975-07-01

    Magnetizing equipment for magnetic particle inspection serves to produce a magnetic field of suitable size and direction in a workpiece under examination. The characteristic parameters of this equipment are given in this standard along with their method of determination if this is necessary. (orig./AK) [de

  9. Configuration management plan for Machine Interface Test System (MITS)

    International Nuclear Information System (INIS)

    O'Neill, C.K.

    1980-01-01

    The discipline required by this plan will apply from the establishment of a configuration baseline until completion of the final test in the MITS. The plan applies to configured items of hardware and software as well as to the specifications and drawings for these items. The plan encompasses establishment of the facility baseline, interface definition, classes of change, change control, change paper, organizational responsibilities and relationships, test configuration (as opposed to facility), and configuration data retention

  10. Automation of a flocculation test for syphilis on Groupamatic equipment.

    Science.gov (United States)

    Garretta, M; Paris-Hamelin, A; Gener, J; Muller, A; Matte, C; Vaisman, A

    1975-01-01

    A flocculation reaction employing a cardiolipid antigen was used for syphilis screening on Groupamatic equipment in parallel with conventional screening reactions: Kolmer CF, RPCF, Kahn, Kline, and RPR. The positive samples were confirmed by FTA-200, FTA-ABS, TPI, and in some cases by TPHA. There were 5,212 known samples which had already been tested by all methods and of which 1,648 were positive, and 58,636 screened samples including 65 positives. Half of the samples in the first series were taken without anticoagulant; the remainder were collected in potassium EDTA. The percentage of false positives with the Groupamatic was about 1-4 per cent. The percentage of false negatives among positve (greater than or equal+) samples varied from 0-18 to 1-3 per cent.; on the other hand the sensitivity was less good for samples giving doubtful and/or dissociated reactions in conventional screening reactions. The specificity and sensitivity of this technique are acceptable for a blood transfusion centre. The reproducibility is excellent and the automatic reading of results accurate. Additional advantages are rapidity (340 samples processed per hour); simultaneous performance of eleven other immunohaematological reactions; no contamination between samples; automatic reading, interpretation, and print-out of results; and saving of time because samples are not filed sequentially and are automatically identified when the results are obtained. Although the importance of syphilis in blood transfusion seems small, estimates of the risk are difficult and further investigations are planned. Images PMID:1098731

  11. XPS Studies of LSCF Interfaces after Cell Testing

    Directory of Open Access Journals (Sweden)

    Gianfranco DiGiuseppe

    2018-01-01

    Full Text Available The motivation of this investigation is to explore the possibility of using the depth profile capability of XPS to study interfaces after SOFC button cell testing. The literature uses XPS to study various cathode materials but has devoted little to the understanding of various cathode interfaces especially after testing. In this work, an SOFC button cell is first tested, and then, the LSCF cathode, barrier layer, and electrolyte are sputtered away to study the behavior of different interfaces. This work has shown that some elements have moved into other layers of the SOFC cell. It is argued that the migration of the elements is partly due to a redeposition mechanism after atoms are sputtered away, while the rest is due to interdiffusion between the SDC and YSZ layers. However, additional work is needed to better understand the mechanism by which atoms move around at different interfaces. The cell electrochemical performance is also discussed in some details but is not the focus.

  12. Reviews Equipment: BioLite Camp Stove Game: Burnout Paradise Equipment: 850 Universal interface and Capstone software Equipment: xllogger Book: Science Magic Tricks and Puzzles Equipment: Spinthariscope Equipment: DC Power Supply HY5002 Web Watch

    Science.gov (United States)

    2013-05-01

    WE RECOMMEND BioLite CampStove Robust and multifaceted stove illuminates physics concepts 850 Universal interface and Capstone software Powerful data-acquisition system offers many options for student experiments and demonstrations xllogger Obtaining results is far from an uphill struggle with this easy-to-use datalogger Science Magic Tricks and Puzzles Small but perfectly formed and inexpensive book packed with 'magic-of-science' demonstrations Spinthariscope Kit for older students to have the memorable experience of 'seeing' radioactivity WORTH A LOOK DC Power Supply HY5002 Solid and effective, but noisy and lacks portability HANDLE WITH CARE Burnout Paradise Car computer game may be quick off the mark, but goes nowhere fast when it comes to lab use WEB WATCH 'Live' tube map and free apps would be a useful addition to school physics, but maths-questions website of no more use than a textbook

  13. Performance test of nutrient control equipment for hydroponic plants

    Science.gov (United States)

    Rahman, Nurhaidar; Kuala, S. I.; Tribowo, R. I.; Anggara, C. E. W.; Susanti, N. D.

    2017-11-01

    Automatic control equipment has been made for the nutrient content in irrigation water for hydroponic plants. Automatic control equipment with CCT53200E conductivity controller to nutrient content in irrigation water for hydroponic plants, can be used to control the amount of TDS of nutrient solution in the range of TDS numbers that can be set according to the range of TDS requirements for the growth of hydroponically cultivated crops. This equipment can minimize the work time of hydroponic crop cultivators. The equipment measurement range is set between 1260 ppm up to 1610 ppm for spinach plants. Caisim plants were included in this experiment along with spinach plants with a spinach plants TDS range. The average of TDS device is 1450 ppm, while manual (conventional) is 1610 ppm. Nutrient solution in TDS controller has pH 5,5 and temperature 29,2 °C, while manual is pH 5,6 and temperature 31,3 °C. Manually treatment to hydroponic plant crop, yields in an average of 39.6 grams/plant, greater than the yield of spinach plants with TDS control equipment, which is in an average of 24.6 grams / plant. The yield of caisim plants by manual treatment is in an average of 32.3 grams/crop, less than caisim crop yields with TDS control equipment, which is in an average of 49.4 grams/plant.

  14. EEG INTERFACE MODULE FOR COGNITIVE ASSESSMENT THROUGH NEUROPHYSIOLOGIC TESTS

    Directory of Open Access Journals (Sweden)

    Kundan Lal Verma

    2014-12-01

    Full Text Available The cognitive signal processing is one of the important interdisciplinary field came from areas of life sciences, psychology, psychiatry, engi-neering, mathematics, physics, statistics and many other fields of research. Neurophysiologic tests are utilized to assess and treat brain injury, dementia, neurological conditions, and useful to investigate psychological and psychiatric disorders. This paper presents an ongoing research work on development of EEG interface device based on the principles of cognitive assessments and instrumentation. The method proposed engineering and science of cogni-tive signal processing in case of brain computer in-terface based neurophysiologic tests. The future scope of this study is to build a low cost EEG device for various clinical and pre-clinical applications with specific emphasis to measure the effect of cognitive action on human brain.

  15. INTERFACE DEVICE FOR NONDESTRUCTIVE TESTING OF RESIDUAL SURFACE STRESSES

    Directory of Open Access Journals (Sweden)

    Gennady A. Perepelkin

    2016-01-01

    Full Text Available The paper considers the organization of connection of a personal computer with a device for nondestructive testing of residual surface stresses. The device works is based on the phenomenon of diffraction of ionizing radiation from the crystal lattice near the surface of the crystallites. Proposed software interface to the organization for each type of user: the device developers, administrators, users. Some aspects of the organization of communication microcontroller to a PC via USB-port

  16. Apollo experience report: Development flight instrumentation. [telemetry equipment for space flight test program

    Science.gov (United States)

    Farmer, N. B.

    1974-01-01

    Development flight instrumentation was delivered for 25 Apollo vehicles as Government-furnished equipment. The problems and philosophies of an activity that was concerned with supplying telemetry equipment to a space-flight test program are discussed. Equipment delivery dates, system-design details, and flight-performance information for each mission also are included.

  17. New equipment for the needs of mobile automatic ultrasonic testing

    International Nuclear Information System (INIS)

    Cost, H.; Vogt, M.

    1989-01-01

    A newly designed system of equipment - ECHOGRAPH 1030 MULTI - for multiplex operation is introduced. The frequency control unit which can distribute a pulse sequency frequency from a maximum of 8 KHz to up to 8 cycles and the monitor evaluation, are described. (MM) [de

  18. Zirconium Recycle Test Equipment for Hot Cell Operations

    International Nuclear Information System (INIS)

    Collins, Emory D.; DelCul, Guillermo Daniel; Spencer, Barry B.; Bradley, Eric Craig; Brunson, Ronald Ray

    2015-01-01

    The equipment components and assembly support work were modified for optimized, remote hot cell operations to complete this milestone. The modifications include installation of a charging door, Swagelok connector for the off-gas line between the reactor and condenser, and slide valve installation to permit attachment/replacement of the product salt collector bottle.

  19. A generalized development model for testing GPS user equipment

    Science.gov (United States)

    Hemesath, N.

    1978-01-01

    The generalized development model (GDM) program, which was intended to establish how well GPS user equipment can perform under a combination of jamming and dynamics, is described. The systems design and the characteristics of the GDM are discussed. The performance aspects of the GDM are listed and the application of the GDM to civil aviation is examined.

  20. Maintenance and test strategies to optimize NPP equipment performance

    International Nuclear Information System (INIS)

    Mayer, S.; Tomic, B.

    2000-01-01

    This paper proposes an approach to maintenance optimization of nuclear power plant components, which can help to increase both safety and availability. In order to evaluate the benefits of preventive maintenance on a quantitative basis, a software code has been developed for component performance and reliability simulation of safety related nuclear power plant equipment. A three state Markov model will be introduced, considering a degraded state in addition to an operational state and a failed state. (author)

  1. A Study on Performance and Safety Tests of Electrosurgical Equipment.

    Science.gov (United States)

    Tavakoli Golpaygani, A; Movahedi, M M; Reza, M

    2016-09-01

    Modern medicine employs a wide variety of instruments with different physiological effects and measurements. Periodic verifications are routinely used in legal metrology for industrial measuring instruments. The correct operation of electrosurgical generators is essential to ensure patient's safety and management of the risks associated with the use of high and low frequency electrical currents on human body. The metrological reliability of 20 electrosurgical equipment in six hospitals (3 private and 3 public) was evaluated in one of the provinces of Iran according to international and national standards. The achieved results show that HF leakage current of ground-referenced generators are more than isolated generators and the power analysis of only eight units delivered acceptable output values and the precision in the output power measurements was low. Results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially in high risk instruments. It is also necessary to provide training courses for operating staff in the field of meterology in medicine to be acquianted with critical parameters to get accuracy results with operation room equipment.

  2. A Study on Performance and Safety Tests of Electrosurgical Equipment

    Directory of Open Access Journals (Sweden)

    Tavakoli Golpaygani A.

    2016-09-01

    Full Text Available Introduction: Modern medicine employs a wide variety of instruments with different physiological effects and measurements. Periodic verifications are routinely used in legal metrology for industrial measuring instruments. The correct operation of electrosurgical generators is essential to ensure patient’s safety and management of the risks associated with the use of high and low frequency electrical currents on human body. Material and Methods: The metrological reliability of 20 electrosurgical equipment in six hospitals (3 private and 3 public was evaluated in one of the provinces of Iran according to international and national standards. Results: The achieved results show that HF leakage current of ground-referenced generators are more than isolated generators and the power analysis of only eight units delivered acceptable output values and the precision in the output power measurements was low. Conclusion: Results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially in high risk instruments. It is also necessary to provide training courses for operating staff in the field of meterology in medicine to be acquianted with critical parameters to get accuracy results with operation room equipment.

  3. Ergonomic Models of Anthropometry, Human Biomechanics and Operator-Equipment Interfaces

    Science.gov (United States)

    Kroemer, Karl H. E. (Editor); Snook, Stover H. (Editor); Meadows, Susan K. (Editor); Deutsch, Stanley (Editor)

    1988-01-01

    The Committee on Human Factors was established in October 1980 by the Commission on Behavioral and Social Sciences and Education of the National Research Council. The committee is sponsored by the Office of Naval Research, the Air Force Office of Scientific Research, the Army Research Institute for the Behavioral and Social Sciences, the National Aeronautics and Space Administration, and the National Science Foundation. The workshop discussed the following: anthropometric models; biomechanical models; human-machine interface models; and research recommendations. A 17-page bibliography is included.

  4. Test of remote control cutting equipment by Nd:YAG laser

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, Akio [Fuji Electric Corp. Research and Development Ltd., Yokosuka, Kanagawa (Japan); Hosoda, Hiroshi

    1997-11-01

    Technology of remote controlled cutting and reduction of generative secondary products have been required to the cutting system for decommissioning nuclear equipments. At a point of view that laser cutting technology by use of a Nd:YAG laser is effective, we have developed the laser cutting machine and carried out cutting tests for several stainless steel plates. This report is described the result of experiment by test equipment, about element technology of remote controlled cutting nuclear equipments. (author)

  5. Test of remote control cutting equipment by Nd:YAG laser

    International Nuclear Information System (INIS)

    Shimizu, Akio; Hosoda, Hiroshi.

    1997-01-01

    Technology of remote controlled cutting and reduction of generative secondary products have been required to the cutting system for decommissioning nuclear equipments. At a point of view that laser cutting technology by use of a Nd:YAG laser is effective, we have developed the laser cutting machine and carried out cutting tests for several stainless steel plates. This report is described the result of experiment by test equipment, about element technology of remote controlled cutting nuclear equipments. (author)

  6. LIQUID AIR INTERFACE CORROSION TESTING FOR FY2010

    International Nuclear Information System (INIS)

    Zapp, P.

    2010-01-01

    An experimental study was undertaken to investigate the corrosivity to carbon steel of the liquid-air interface of dilute simulated radioactive waste solutions. Open-circuit potentials were measured on ASTM A537 carbon steel specimens located slightly above, at, and below the liquid-air interface of simulated waste solutions. The 0.12-inch-diameter specimens used in the study were sized to respond to the assumed distinctive chemical environment of the liquid-air interface, where localized corrosion in poorly inhibited solutions may frequently be observed. The practical inhibition of such localized corrosion in liquid radioactive waste storage tanks is based on empirical testing and a model of a liquid-air interface environment that is made more corrosive than the underlying bulk liquid due to chemical changes brought about by absorbed atmospheric carbon dioxide. The chemical changes were assumed to create a more corrosive open-circuit potential in carbon in contact with the liquid-air interface. Arrays of 4 small specimens spaced about 0.3 in. apart were partially immersed so that one specimen contacted the top of the meniscus of the test solution. Two specimens contacted the bulk liquid below the meniscus and one specimen was positioned in the vapor space above the meniscus. Measurements were carried out for up to 16 hours to ensure steady-state had been obtained. The results showed that there was no significant difference in open-circuit potentials between the meniscus-contact specimens and the bulk-liquid-contact specimens. With the measurement technique employed, no difference was detected between the electrochemical conditions of the meniscus versus the bulk liquid. Stable open-circuit potentials were measured on the specimen located in the vapor space above the meniscus, showing that there existed an electrochemical connection through a thin film of solution extending up from the meniscus. This observation supports the Hobbs-Wallace model of the development

  7. 14 CFR Appendix J to Part 23 - HIRF Environments and Equipment HIRF Test Levels

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false HIRF Environments and Equipment HIRF Test Levels J Appendix J to Part 23 Aeronautics and Space FEDERAL AVIATION ADMINISTRATION, DEPARTMENT OF.... 23, App. J Appendix J to Part 23—HIRF Environments and Equipment HIRF Test Levels This appendix...

  8. Performance testing of medical US equipment using US phantom (ATS-539)

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Do Hyung [Daegu Branch, Korea Association of Health Promotion, Daegu (Korea, Republic of); Kwon, Deok Moon [Dept. of Radiology, Daegu Health College, Daegu (Korea, Republic of)

    2014-12-15

    This study is to provide accurate information as medical imaging equipment to check for the presence of body disease US equipment. We investigated the status of medical US equipment performance in Daegu and criteria US phantom (ATS-539) for US equipment performance measurements. The results in this study, 1. US phantom measurement results: The test passed rate were 88.6% and the failed rate were 11.4%. 2. The difference between the group of mean and the pass/failed groups were statistically significant. Focal zone and 4 mm functional resolution in the two items that are not present the passing standard. 3. The difference was statistically significant number of years and used equipment and pass the failed equipment (4.13 vs 7.25 years). We investigated the performance status of US equipment used in the clinical area in Daegu. The basis for the two items are not present this proposed passing standard. Equipment performance was associated with the number of years of using US equipment. It is necessary to maintain the best performance of the equipment phantom measurements for performance testing of US equipment.

  9. Performance testing of medical US equipment using US phantom (ATS-539)

    International Nuclear Information System (INIS)

    Kim, Do Hyung; Kwon, Deok Moon

    2014-01-01

    This study is to provide accurate information as medical imaging equipment to check for the presence of body disease US equipment. We investigated the status of medical US equipment performance in Daegu and criteria US phantom (ATS-539) for US equipment performance measurements. The results in this study, 1. US phantom measurement results: The test passed rate were 88.6% and the failed rate were 11.4%. 2. The difference between the group of mean and the pass/failed groups were statistically significant. Focal zone and 4 mm functional resolution in the two items that are not present the passing standard. 3. The difference was statistically significant number of years and used equipment and pass the failed equipment (4.13 vs 7.25 years). We investigated the performance status of US equipment used in the clinical area in Daegu. The basis for the two items are not present this proposed passing standard. Equipment performance was associated with the number of years of using US equipment. It is necessary to maintain the best performance of the equipment phantom measurements for performance testing of US equipment

  10. Seismic test qualification of electrical equipment - testing methods in use to EDF

    International Nuclear Information System (INIS)

    Fabries, R.

    1981-01-01

    At the beginning, for the 900 MW Power Plant level, the testing method in application used the single axis test by sine beat of 10 cycles according to the specifications of the guide IEEE 344-71. When the french guide UTEC 20-420 came into force we have had to define another testing method (EDF standard: HN20 E52) which utilize the single-axis test either by a sine beat of 5-cycles or by a synthetized time history. We present here the mains criterions allowing to justify: -The single-axis test. The single frequency wave (when the Initial Response Spectrum (IRS) present a narrow band). The use of one sine beat of 5-cycles or one synthetized time history. The need of taking into account the high stress level. This oligocyclic stress fatigue explains why one beat of 5-cycles may be as severe as one time history of 20 seconds (with the same level of strong response spectrum). Then, we conclude that the durating of the testing wave applied to the equipment shall be considered as a relative parameter only. The weight of the SSE tests by respect to the OBE tests. The precautions to take in order to: generate and check accurately the synthetized time history, choice the test frequencies when the sine beat is used. (orig./HP)

  11. The introduction of compulsory compliance testing of medical diagnostic x-ray equipment in Western Australia

    International Nuclear Information System (INIS)

    Rafferty, M. W.; Jacob, C. S.

    1995-01-01

    Performance testing of medical diagnostic X-ray equipment can reveal equipment faults which, while not always clinically detectable, may contribute to reduced image quality and unnecessary radiation exposure of both patients and staff. Routine testing of such equipment is highly desirable to identify such faults and allows them to be rectified. The Radiological council of Western Australia is moving towards requiring compulsory compliance testing of all (new and existing) medical diagnostic X-ray equipment that all new mobile radiographic and new mammographic X-ray equipment be issued with a compliance test certificate as a prerequisite for registration. Workbooks which provide details of the tests required and recommended test methods have been prepared for medical radiographic (mobile and fixed), fluoroscopic and mammographic X-ray equipment. It is intended that future workbooks include details of the tests and methods for dental and computed tomography X-ray units. The workbooks are not limited to the compliance testing of items as specified in the Regulations, but include tests for other items such as film processing, darkrooms and image quality (for fluoroscopic equipment). Many of the workbook tests could be used within a regular quality assurance program for diagnostic X-ray equipment. Persons who conduct such compliance tests will need to be licensed and have all test certificates endorsed by a qualified expert. Suitable training and assessment of compliance testers will be required. Notification of such tests (including non-compliant items and corrective actions taken) will be required by the Radiological Council as a condition of equipment registration. 9 refs

  12. A Study on Performance and Safety Tests of Defibrillator Equipment

    Directory of Open Access Journals (Sweden)

    Tavakoli Golpaygani A.

    2017-12-01

    Full Text Available Introduction: Nowadays, more than 10,000 different types of medical devices can be found in hospitals. This way, medical electrical equipment is being employed in a wide variety of fields in medical sciences with different physiological effects and measurements. Hospitals and medical centers must ensure that their critical medical devices are safe, accurate, reliable and operational at the required level of performance. Defibrillators are critical resuscitation devices. The use of reliable defibirillators has led to more effective treatments and improved patient safety through better control and management of complications during Cardiopulmonary Resuscitation (CPR. Materials and Methods: The metrological reliability of twenty frequent use, manual defibrillators in use ten hospitals (4 private and 6 public in one of the provinces of Iran according to international and national standards was evaluated. Results: Quantitative analysis of control and instrument accuracy showed the amount of the obtained results in many units are critical which had less value over the standard limitations especially in devices with poor battery. For the accuracy of delivered energy analysis, only twelve units delivered acceptable output values and the precision in the output energy measurements especialy in weak battry condition, after activation of discharge alarm, were low. Conclusion: Obtained results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially for high risk instruments. It is also necessary to provide training courses on the fundumentals of operation and performane parameters for medical staff in the field of meterology in medicine and how one can get good accuracy results especially in high risk medical devices.

  13. A Study on Performance and Safety Tests of Defibrillator Equipment.

    Science.gov (United States)

    Tavakoli Golpaygani, A; Movahedi, M M; Reza, M

    2017-12-01

    Nowadays, more than 10,000 different types of medical devices can be found in hospitals. This way, medical electrical equipment is being employed in a wide variety of fields in medical sciences with different physiological effects and measurements. Hospitals and medical centers must ensure that their critical medical devices are safe, accurate, reliable and operational at the required level of performance. Defibrillators are critical resuscitation devices. The use of reliable defibirillators has led to more effective treatments and improved patient safety through better control and management of complications during Cardiopulmonary Resuscitation (CPR). The metrological reliability of twenty frequent use, manual defibrillators in use ten hospitals (4 private and 6 public) in one of the provinces of Iran according to international and national standards was evaluated. Quantitative analysis of control and instrument accuracy showed the amount of the obtained results in many units are critical which had less value over the standard limitations especially in devices with poor battery. For the accuracy of delivered energy analysis, only twelve units delivered acceptable output values and the precision in the output energy measurements especialy in weak battry condition, after activation of discharge alarm, were low. Obtained results indicate a need for new and severe regulations on periodic performance verifications and medical equipment quality control program especially for high risk instruments. It is also necessary to provide training courses on the fundumentals of operation and performane parameters for medical staff in the field of meterology in medicine and how one can get good accuracy results especially in high risk medical devices.

  14. Test strategies for industrial testers for converter controls equipment

    International Nuclear Information System (INIS)

    Oleniuk, P.; Kasampalis, V.; Cosmo, M. Di; Nisbet, D.; Todd, B.; Uznański, S.

    2017-01-01

    Power converters and their controls electronics are key elements for the operation of the CERN accelerator complex, having a direct impact on its availability. To prevent early-life failures and provide means to verify electronics, a set of industrial testers is used throughout the converters controls electronics' life cycle. The roles of the testers are to validate mass production during the manufacturing phase and to provide means to diagnose and repair failed modules that are brought back from operation. In the converter controls electronics section of the power converters group in the technology department of CERN (TE/EPC/CCE), two main test platforms have been adopted: a PXI platform for mixed analogue-digital functional tests and a JTAG Boundary-Scan platform for digital interconnection and functional tests. Depending on the functionality of the device under test, the appropriate test platforms are chosen. This paper is a follow-up to results presented at the TWEPP 2015 conference, adding the boundary scan test platform and the first results from exploitation of the test system. This paper reports on the test software, hardware design and test strategy applied for a number of devices that has resulted in maximizing test coverage and minimizing test design effort.

  15. Seismic fragility capacity of equipment--horizontal shaft pump test

    International Nuclear Information System (INIS)

    Iijima, T.; Abe, H.; Suzuki, K.

    2005-01-01

    The current seismic fragility capacity of horizontal shaft pump is 1.6 x 9.8 m/s 2 (1.6 g), which was decided from previous vibration tests and we believe that it must have sufficient margin. The purpose of fragility capacity test is to obtain realistic seismic fragility capacity of horizontal shaft pump by vibration tests. Reactor Building Closed Cooling Water (RCW) Pump was tested as a typical horizontal shaft pump, and then bearings and liner rings were tested as important parts to evaluate critical acceleration and dispersion. Regarding RCW pump test, no damage was found, though maximum input acceleration level was 6 x 9.8 m/s 2 (6 g). Some kinds of bearings and liner rings were tested on the element test. Input load was based on seismic motion which was same with the RCW pump test, and maximum load was equivalent to over 20 times of design seismic acceleration. There was not significant damage that caused emergency stop of pump but degradation of surface roughness was found on some kinds of bearings. It would cause reduction of pump life, but such damage on bearings occurred under large seismic load condition that was equivalent to over 10 to 20 g force. Test results show that realistic fragility capacity of horizontal shaft pump would be at least four times as higher as current value which has been used for our seismic PSA. (authors)

  16. Acceptance test procedure for K basins dose reduction project clean and coat equipment

    International Nuclear Information System (INIS)

    Creed, R.F.

    1996-01-01

    This document is the Acceptance Test Procedure (ATP) for the clean and coat equipment designed by Oceaneering Hanford, Inc. under purchase order MDK-XVC-406988 for use in the 105 K East Basin. The ATP provides the guidelines and criteria to test the equipment's ability to clean and coat the concrete perimeter, divider walls, and dummy elevator pit above the existing water level. This equipment was designed and built in support of the Spent Nuclear Fuel, Dose Reduction Project. The ATP will be performed at the 305 test facility in the 300 Area at Hanford. The test results will be documented in WHC-SD-SNF-ATR-020

  17. Flexible thermal cycle test equipment for concentrator solar cells

    Science.gov (United States)

    Hebert, Peter H [Glendale, CA; Brandt, Randolph J [Palmdale, CA

    2012-06-19

    A system and method for performing thermal stress testing of photovoltaic solar cells is presented. The system and method allows rapid testing of photovoltaic solar cells under controllable thermal conditions. The system and method presents a means of rapidly applying thermal stresses to one or more photovoltaic solar cells in a consistent and repeatable manner.

  18. Systematic approach in protection and ergonomics testing personal protective equipment

    NARCIS (Netherlands)

    Hartog. E.A. den

    2009-01-01

    In the area of personal protection against chemical and biological (CB) agents there is a strong focus on testing the materials against the relevant threats. The testing programs in this area are elaborate and are aimed to guarantee that the material protects according to specifications. This

  19. Shuttle orbiter Ku-band radar/communications system design evaluation. Deliverable test equipment evaluation

    Science.gov (United States)

    Maronde, R. G.

    1980-07-01

    The Ku-band test equipment, known as the Deliverable System Test equipment (DSTE), is reviewed and evaluated. The DSTE is semiautomated and computer programs were generated for 14 communication mode tests and 17 radar mode tests. The 31 test modules provide a good cross section of tests with which to exercise the Ku-band system; however, it is very limited when being used to verify Ku-band system performance. More detailed test descriptions are needed, and a major area of concern is the DSTE sell-off procedure which is inadequate.

  20. 78 FR 63410 - Energy Conservation Program for Consumer Products: Test Procedures for Direct Heating Equipment...

    Science.gov (United States)

    2013-10-24

    ... test procedures for direct heating equipment and pool heaters established under the Energy Policy and... U.S.C. 6293(e)(2)) The current energy conservation standards for direct heating equipment and pool... DEPARTMENT OF ENERGY 10 CFR Part 430 [Docket Number EERE-2013-BT-TP-0004] RIN 1904-AC94 Energy...

  1. Tests of the particle physics-physical cosmology interface

    International Nuclear Information System (INIS)

    Schramm, D.N.

    1993-01-01

    Three interrelated interfaces of particle physics and physical cosmology are discussed: (1) inflation and other phase transitions; (2) Big Bang Nucleosynthesis (and also the quark-hadron transition); and (3) structure formation (including dark matter). Recent observations that affect each of these topics are discussed. Topic number 1 is shown to be consistent with the COBE observations but not proven and it may be having problems with some age-expansion data. Topic number 2 has now been well-tested and is an established ''pillar'' of the Big Bang. Topic number 3 is the prime arena of current physical cosmological activity. Experiments to resolve the current exciting, but still ambiguous, situation following the COBE results are discussed

  2. submitter Test strategies for industrial testers for converter controls equipment

    CERN Document Server

    Oleniuk, P; Kasampalis, V; Nisbet, D; Todd, B; Uznański, S

    2017-01-01

    Power converters and their controls electronics are key elements for the operation of the CERN accelerator complex, having a direct impact on its availability. To prevent early-life failures and provide means to verify electronics, a set of industrial testers is used throughout the converters controls electronics' life cycle. The roles of the testers are to validate mass production during the manufacturing phase and to provide means to diagnose and repair failed modules that are brought back from operation. In the converter controls electronics section of the power converters group in the technology department of CERN (TE/EPC/CCE), two main test platforms have been adopted: a PXI platform for mixed analogue-digital functional tests and a JTAG Boundary-Scan platform for digital interconnection and functional tests. Depending on the functionality of the device under test, the appropriate test platforms are chosen. This paper is a follow-up to results presented at the TWEPP 2015 conference, adding the boundary s...

  3. Direct ultimate disposal of spent fuel elements. Mechanical equipment tests

    International Nuclear Information System (INIS)

    Filbert, W.; Schrimpf, C.

    1990-02-01

    Simulation of the shaft transport of waste forms is described. Proceeding from a concept of a shaft hoist with a payload of 85 t, the applicability of the state of the art of essential components, such as hoisting machine, cage and hoisting cables, to such payloads is described. For these components a test stand has been planned which meets safety-related regulations. (DG) [de

  4. Novel Field Test Equipment for Lithium-Ion Batteries in Hybrid Electrical Vehicle Applications

    Directory of Open Access Journals (Sweden)

    Goran Lindbergh

    2011-04-01

    Full Text Available Lifetime testing of batteries for hybrid-electrical vehicles (HEV is usually performed in the lab, either at the cell, module or battery pack level. Complementary field tests of battery packs in vehicles are also often performed. There are, however, difficulties related to field testing of battery-packs. Some examples are cost issues and the complexity of continuously collecting battery performance data, such as capacity fade and impedance increase. In this paper, a novel field test equipment designed primarily for lithium-ion battery cell testing is presented. This equipment is intended to be used on conventional vehicles, not hybrid vehicles, as a cheaper and faster field testing method for batteries, compared to full scale HEV testing. The equipment emulates an HEV environment for the tested battery cell by using real time vehicle sensor information and the existing starter battery as load and source. In addition to the emulated battery cycling, periodical capacity and pulse testing capability are implemented as well. This paper begins with presenting some background information about hybrid electrical vehicles and describing the limitations with today’s HEV battery testing. Furthermore, the functionality of the test equipment is described in detail and, finally, results from verification of the equipment are presented and discussed.

  5. Cold Regions Logistic Supportability Testing of Electronic, Avionic and Communications Equipment.

    Science.gov (United States)

    1985-06-20

    Comment : 2. Have all data collected been reviewed for correctness and completeness? YES NO . Comment : 3. Were the facilities, test equipment...insufficient test planning? YES NO . Comment : 5. Were the test results compromised in any way due to test performance procedures? YES NO . Comment : 6. Were the...test results compromised in any way due to test control pro- cedures? YES NO Comment : 7. Were the test results compromised in any way due to data

  6. Advances in impact resistance testing for explosion-proof electrical equipment

    Directory of Open Access Journals (Sweden)

    Pasculescu Vlad Mihai

    2017-01-01

    Full Text Available The design, construction and exploitation of electrical equipment intended to be used in potentially explosive atmospheres presents a series of difficulties. Therefore, the approach of these phases requires special attention concerning technical, financial and occupational health and safety aspects. In order for them not to generate an ignition source for the explosive atmosphere, such equipment have to be subjected to a series of type tests aiming to decrease the explosion risk in technological installations which operate in potentially explosive atmospheres. Explosion protection being a concern of researchers and authorities worldwide, testing and certification of explosion-proof electrical equipment, required for their conformity assessment, are extremely important, taking into account the unexpected explosion hazard due to potentially explosive atmospheres, risk which has to be minimized in order to ensure the occupational health and safety of workers, for preventing material losses and for decreasing the environmental pollution. Besides others, one of the type tests, which shall be applied, for explosion-proof electrical equipment is the impact resistance test, described in detail in EN 60079 which specifies the general requirements for construction, testing and marking of electrical equipment and Ex components intended for use in explosive atmospheres. This paper presents an analysis on the requirements of the impact resistance test for explosion-proof electrical equipment and on the possibilities to improve this type of test, by making use of modern computer simulation tools based on finite element analysis, techniques which are widely used nowadays in the industry and for research purposes.

  7. Enhancing reliability of ultrasonic testing of welds of nuclear power plant equipment

    International Nuclear Information System (INIS)

    Shcherbinskij, V.G.

    1981-01-01

    Results of investigation of factors influencing the reliability of manual ultrasonic testing of welded joints and weld deposited metal power-generating equipment are presented. Recommendations on the enhancing of reliability are given [ru

  8. Fracture toughness versus micro-tensile bond strength testing of adhesive-dentin interfaces.

    Science.gov (United States)

    De Munck, Jan; Luehrs, Anne-Katrin; Poitevin, André; Van Ende, Annelies; Van Meerbeek, Bart

    2013-06-01

    To assess interfacial fracture toughness of different adhesive approaches and compare to a standard micro-tensile bond-strength (μTBS) test. Chevron-notched beam fracture toughness (CNB) was measured following a modified ISO 24370 standard. Composite bars with dimensions of 3.0×4.0×25 mm were prepared, with the adhesive-dentin interface in the middle. At the adhesive-dentin interface, a chevron notch was prepared using a 0.15 mm thin diamond blade mounted in a water-cooled diamond saw. Each specimen was loaded until failure in a 4-point bend test setup and the fracture toughness was calculated according to the ISO specifications. Similarly, adhesive-dentin micro-specimens (1.0×1.0×8-10 mm) were stressed in tensile until failure to determine the μTBS. A positive correlation (r(2)=0.64) was observed between CNB and μTBS, which however was only nearly statistically significant, mainly due to the dissimilar outcome of Scotchbond Universal (3M ESPE). While few μTBS specimens failed at the adhesive-dentin interface, almost all CNB specimens failed interfacially at the notch tip. Weibull moduli for interfacial fracture toughness were much higher than for μTBS (3.8-11.5 versus 2.7-4.8, respectively), especially relevant with regard to early failures. Although the ranking of the adhesives on their bonding effectiveness tested using CNB and μTBS corresponded well, the outcome of CNB appeared more reliable and less variable. Fracture toughness measurement is however more laborious and requires specific equipment. The μTBS nevertheless appeared to remain a valid method to assess bonding effectiveness in a versatile way. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  9. Versatile equipment for mechanical testing of active materials

    International Nuclear Information System (INIS)

    Bertsch, Johannes; Heimgartner, Peter

    2005-01-01

    At the Paul Scherrer Institute (PSI) 3 different project groups presently perform aging research on active materials. The research fields are fusion, high neutron flux targets and LWR relevant components. Up to now mechanical testing has been performed with small, low dose rate samples behind local shielding, not appropriate for highly activated material. To overcome this situation, a cell concept for active mechanical testing was elaborated and has been erected in PSI's Hotlab. It consists of 4 shielded cells. 3 connected cells are versatile and independently operable for highly beta/gamma active samples. One cell is an alpha/beta/gamma-box which will be realized in a second phase. This paper presents the versatility especially of the beta/gamma-cells: The different user groups perform experiments in these cells, whereas different machines can be placed into the cells. As consequence of the need of heavily shielded cell doors, a special strengthening and levelling of the floor has been required. In all cells the relevant media are installed. Besides the performance of the cells, the project progress as the difficulties and their solutions are described. (Author)

  10. Reliability of nondestructive testing of metal strength properties for power equipment

    International Nuclear Information System (INIS)

    Bugaj, N.V.; Lebedev, A.A.; Sharko, A.V.

    1985-01-01

    Ultrasonic control which is a constituent part of a complex control system which includes specimen-free (by hardness) tests, random breaking tests and acoustic measurements is stUdied for its reliability with respect to strength properties of power-equipment metal. Quantitative and alternative criteria are developed to estimate quality of elements for power-equipment according to results of metal strength properties. Acoustic control results are presented for ultimate strength in 12Kh1MF-steel

  11. Guidelines for Electromagnetic Interference Testing of Power Plant Equipment: Revision 3 to TR-102323

    Energy Technology Data Exchange (ETDEWEB)

    J. Cunningham and J. Shank

    2004-11-01

    To continue meeting safety and reliability requirements while controlling costs, operators of nuclear power plants must be able to replace and upgrade equipment in a cost-effective manner. One issue that has been problematic for new plant equipment and especially for digital instrumentation and control (I&C) systems in recent years is electromagnetic compatibility (EMC). The EMC issue usually involves testing to show that critical equipment will not be adversely affected by electromagnetic interference (EMI) in the plant environment. This guide will help nuclear plant engineers address EMC issues and qualification testing in a consistent, comprehensive manner.

  12. Guidelines for Electromagnetic Interference Testing of Power Plant Equipment: Revision 3 to TR-102323

    International Nuclear Information System (INIS)

    Cunningham, J.; Shank, J.

    2004-01-01

    To continue meeting safety and reliability requirements while controlling costs, operators of nuclear power plants must be able to replace and upgrade equipment in a cost-effective manner. One issue that has been problematic for new plant equipment and especially for digital instrumentation and control (I and C) systems in recent years is electromagnetic compatibility (EMC). The EMC issue usually involves testing to show that critical equipment will not be adversely affected by electromagnetic interference (EMI) in the plant environment. This guide will help nuclear plant engineers address EMC issues and qualification testing in a consistent, comprehensive manner

  13. Program outline of seismic fragility capacity tests on nuclear power plant equipment

    International Nuclear Information System (INIS)

    Lijima, T.; Abe, H.; Fujita, T.

    2004-01-01

    A seismic probabilistic safety assessment (PSA) is an available method to evaluate residual risk of nuclear plant that is designed with definitive seismic design condition. Seismic fragility capacity data are necessary for seismic PSA, but we don't have sufficient data of active components of nuclear plants in Japan. This paper describes a plan of seismic fragility capacity tests on nuclear power plant equipment. The purpose of those tests is to obtain seismic fragility capacity of important equipment from a safety design point of view. And the equipment for the fragility capacity tests were selected considering effect on core damage frequency (CDF) that was evaluated by our preliminary seismic PSA. Consequently horizontal shaft pump, electric cabinets, Control Rod Drive system (CRD system) of BWR and PWR plant and vertical shaft pump were selected. The seismic fragility capacity tests are conducted from phase-1 to phase-3, and horizontal shaft pump and electric cabinets are tested on phase-1. The fragility capacity test consists of two types of tests. One is actual equipment test and another is element test. On actual equipment test, a real size model is tested with high-level seismic motion, and critical acceleration and failure mode are investigated. Regarding fragility test phase-1, we selected typical type horizontal shaft pump and electric cabinets for the actual equipment test. Those were Reactor Building Closed Cooling Water (RCW) Pump and eight kinds of electric cabinets such as relay cabinet, motor control center. On the test phase-1, maximum input acceleration for the actual equipment test is intended to be 6-G-force. Since the shaking table of TADOTSU facility did not have capability for high acceleration, we made vibration amplifying system. In this system, amplifying device is mounted on original shaking table and it moves in synchronization with original table. The element test is conducted with many samples and critical acceleration, median and

  14. Methodically finding solutions of equipments for carrying out experiments in materials testing and research. Pt. 2

    International Nuclear Information System (INIS)

    Findeisen, D.; Nachtweide, D.; Kuntze, G.

    1983-01-01

    In comparison with the development of industrial products the development of test equipments is of special kind, which is demonstrated by methodical proceeding for finding solutions and by potentialities for technical design and production of test equipment engineering. Some general principles are turned out and explained by several realized examples of design belonging to the sphere of materials testing in den Federal Institute of Materials Testing (BAM) representative of other problems. User are large scientific institutes independent of university, scientific institutes as members of university just as test stands and quality control offices of industrial works. (orig.) [de

  15. Evaluation tests of the Instrumentation and Control equipment to use in nuclear power plants: its contribution to the improvement and quality certification of the Brazilian equipment

    International Nuclear Information System (INIS)

    Menezes, R.H.M. de; Peluso, M.A.V.

    1984-01-01

    This work presents the procedures used to evaluate Instrumentation Control equipment and reports the experience of integration among instrument user, manufacturer and test institution. It covers tests for equipments for conventional user and for specific application in Nuclear Power Stations. (Author) [pt

  16. System for routine testing of self-contained and airline breathing equipment

    Energy Technology Data Exchange (ETDEWEB)

    McDermott, H.J.; Hermens, G.A.

    1980-07-01

    A system for routine testing of self-contained and airline breathing equipment, developed by Shell Oil Co., for testing breathing equipment at one of its refineries, consists of an 80 psig air supply for airline respirators; a 500-2100 psig air supply for self-contained units; a regulator test system which uses a mannequin head that simulates human inhalation and which tests the ability of the regulator to keep the mask interior at the correct positive pressure; and an exhalation valve test system which identifies a leaky or sticking valve. The testing system has been in use for about 30 mo and has led to increased acceptance of respiratory protective equipment by workers.

  17. Welding of sule elements for nuclear reactors with solid state YAG laser using instrumentated testing equipments

    International Nuclear Information System (INIS)

    Bourgault, F.; Lacoste, J.; Schley, R.; Kluzinski, C.; Piednoir, P.

    1985-09-01

    The instrumentation of the equipment for carrying out safety tests on fuel elements for nuclear reactors requires special thermocouples adapted to the prevailing agressive medium. The investigations described deal essentially with the operational and metallurgical weldability tests out on the safety test zircaloy piping in the pressurized water circuit (PHEBUS-programme) [fr

  18. 42 CFR 493.1252 - Standard: Test systems, equipment, instruments, reagents, materials, and supplies.

    Science.gov (United States)

    2010-10-01

    ... 42 Public Health 5 2010-10-01 2010-10-01 false Standard: Test systems, equipment, instruments... SERVICES, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) STANDARDS AND CERTIFICATION LABORATORY... storage of reagents and specimens, accurate and reliable test system operation, and test result reporting...

  19. The qualification requirements for personnel carry out the testing for the pressure equipment materials

    International Nuclear Information System (INIS)

    Wojas, M.; Walczak, M.

    2006-01-01

    The article contains information about qualification requirements for personnel carry out the destructive and non-destructive testing for the pressure equipment materials based on the Directive 97/23/CE(PED). Competence laboratory carry out the testing. The responsibility lies with producer / employer. The producer / employer could elaborate the written practice procedure for qualification and certification testing personnel. (authors)

  20. Performance test of ex-core high temperature and high pressure water loop test equipment (Contract research)

    International Nuclear Information System (INIS)

    Nakano, Hiroko; Uehara, Toshiaki; Takeuchi, Tomoaki; Shibata, Hiroshi; Nakamura, Jinichi; Matsui, Yoshinori; Tsuchiya, Kunihiko

    2016-03-01

    In Japan Atomic Energy Agency, we started research and development so as to monitor the situations in the Nuclear Plant Facilities during a severe accident, such as a radiation-resistant monitoring camera, a radiation-resistant transmission system for conveying the in-core information, and a heat-resistant signal cable. As a part of developments of the heat-resistant signal cable, we prepared ex-core high-temperature and high-pressure water loop test equipment, which can simulate the conditions of BWRs and PWRs, for evaluating reliability and properties of sheath materials of the cable. This equipment consists of autoclave, water conditioning tank, high-pressure metering pump, preheater, heat exchanger and water purification equipment, etc. This report describes the basic design and the performance test results of ex-core high-temperature and high-pressure water loop test equipment. (author)

  1. Qualification of class 1e equipment: regulation, technological margins and test experience

    International Nuclear Information System (INIS)

    Pasco, Y.; Le Meur, M.; Henry, J.Y.; Droger, J.P.; Morange, E.; Roubault, J.

    1986-10-01

    French regulation requires licensee to qualify electrical equipment important to safety for service in nuclear power plants to ensure that the equipment can perform its safety function under the set of plausible operating conditions. The French regulatory texts entitled Fundamental safety rules have classified safety related electrical equipment in three main categories: k1, k2, k3, according to their location and operating conditions. The definition of a design basis accident test profile must account for margins applied to thermal hydraulic code outputs. Specific safety margins was added to cover uncertainties in qualification test representativity. Up to now, accidental sequence studies have shown the validity of such a qualification test profile. On the other hand, the results from post accident simulation tests have shown that it is useful not only to validate post accident operating life but also to reveal failures initiated during previous tests [fr

  2. Experience in testing and inspection and maintenance of material handling equipments

    International Nuclear Information System (INIS)

    Sharma, M.L.

    2009-01-01

    All the Industries, Power Projects/Stations, Organizations engaged in the field of process of manufacturing, power generation, transportation, design, layout, manufacturing, and supply have to utilize material handling equipment, machinery tools tackles, lifting gears for performing their tasks/activities. The major role of the material handling equipments play an important role and a component of 40% of the total activities of the system/process to achieve targeted output with the reliability and quality is performed by material handling equipment and machineries. The material handling equipment shall have to be chosen/selected to suit the process requirement at times to be specifically designed inspected and tested to meet the specific requirement. These equipment/machineries/lifting gears have to undergo for the periodical inspection and testing to qualify for further use in a specified period. All those equipment and machinery to be used for material handling if not found satisfactory during inspection and testing or otherwise also shall be dismantled/stripped to the extent of inspection requirement of the components/sub components and maintenance repair shall have to be done to make them worthy for reuse after testing and inspection duly witnessed by competent authority

  3. METHODOLOGICAL PROBLEMS AND WAYS OF CREATION OF THE AIRCRAFT EQUIPMENT TEST AUTOMATED MANAGEMENT SYSTEM

    Directory of Open Access Journals (Sweden)

    Vladimir Michailovich Vetoshkin

    2017-01-01

    Full Text Available The development of new and modernization of existing aviation equipment specimens of different classes are ac- companied and completed by the complex process of ground and flight tests. This phase of aviation equipment life cycle is implemented by means of organizational and technical systems - running centers. The latter include various proving grounds, measuring complex and systems, aircraft, ships, security and flight control offices, information processing laborato- ries and many other elements. The system analysis results of development challenges of the automated control systems of aviation equipment tests operations are presented. The automated control systems are in essence an automated data bank. The key role of development of flight tests automated control system in the process of creation of the automated control sys- tems of aviation equipment tests operations is substantiated. The way of the mobile modular measuring complexes integra- tion and the need for national methodologies and technological standards for database systems design concepts are grounded. Database system, as a central element in this scheme, provides collection, storing and updating of values of the elements described above in pace and the required frequency of the controlled object state monitoring. It is database system that pro- vides the supervisory unit with actual data corresponding to specific moments of time, which concern the state processes, assessments of the progress and results of flight experiments, creating the necessary environment for aviation equipment managing and testing as a whole. The basis for development of subsystems of automated control systems of aviation equip- ment tests operations are conceptual design processes of the respective database system, the implementation effectiveness of which largely determines the level of success and ability to develop the systems being created. Introduced conclusions and suggestions can be used in the

  4. Improving the Thermal Testing Technology of Technological Equipment of Autonomous Complexes

    Directory of Open Access Journals (Sweden)

    V. V. Chugunkov

    2017-01-01

    Full Text Available The environmental conditions of autonomous objects of different-purpose technical complexes are in close relationship with increased values of operating temperatures. This requires thermal pretesting of the process equipment. The publication [1] considers the thermal test conditions in which the equipment elements under test are placed in a heated water tank covered by the globe insulators where, under automatic temperature control using a block of heaters, they are then kept for a specified period of time at a specified temperature range. Such an approach to the thermal tests of equipment allows us to reduce, but not eliminate completely the mass flows of water from evaporation with reducing power consumption of test equipment.Despite the results achieved, even a little bit of water vapor available when conducting the thermal tests may cause a failure of equipment. Therefore, there is a need in test equipment modernization for complete eliminating the fluxes of mass water and better power consumption in the test process. To this end, it is proposed to place a three-layer bubble wrap on the open surface of water.To justify an efficiency of the proposed option was developed a mathematical model of heat and mass transfer processes that occur during thermal tests, taking into account the geometric and thermo-physical characteristics of test tank, polymer film, and equipment. Using the laws and equations of heat and mass transfer enabled us to determine the required capacities for heating the tank with water and equipment to the required temperature range for a specified time, as well as the mass flows of water when evaporating from the tank surface.The efficiency of the three-layer bubble film as compared with the globe insulators as the elements for covering the test tank the surface has been analysed on the basis of the results obtained.The proposed film coating allowed almost complete elimination of evaporation losses of water mass and almost 8

  5. First test of a CMS DT chamber equipped with full electronics in a muon beam

    CERN Multimedia

    Jesus Puerta-Pelayo

    2003-01-01

    A CMS DT chamber of MB3 type, equipped with the final version of a minicrate (containing all on-chamber trigger and readout electronics), was tested in a muon beam for the first time. The beam was bunched in 25 ns spills, allowing an LHC-like response of the chamber trigger. This test confirmed the excellent performance of the trigger design.

  6. The Northern Regional Programme for the acceptance testing of X-ray equipment

    International Nuclear Information System (INIS)

    Faulkner, K.; Harrison, R.M.; Kotre, C.J.; Smith, S.; Davies, M.; Barker, P.

    1989-01-01

    Since 1984 the Regional Medical Physics Department has participated in a regional acceptance testing programme for all X-ray equipment from mobile units to computed tomography scanners. The organizational and radiation physics aspects of the programme are described. Three levels of tests are performed by physicists: the first on installation, the second after 3 months, and the final visit just prior to the end of the manufacturer's warranty. The second test is only performed if any aspect of performance requires rechecking as a result of the first visit. Acceptance test protocols are based on those published by the Institute of Physical Sciences in Medicine. Details of the limiting values for the acceptance test measurements are given. The results of the programme are discussed. In some instances the testing has resulted in modifications to the design and construction of X-ray equipment. Acceptance testing is important in determining a baseline standard of performance against which routine quality assurance may be assessed. (author)

  7. The Northern regional programme for the acceptance testing of X-ray equipment

    International Nuclear Information System (INIS)

    Faulkner, K.; Harrison, R.M.; Kotre, C.J.; Smith, S.; Davies, M.; Barker, P.

    1989-01-01

    Since 1984 the UK Northern Regional Medical Physics Department has participated in a regional acceptance testing programme for all X-ray equipment from mobile units to computed tomography scanners. Organizational and radiation physics aspects of the programme are described. Three levels of tests are performed by physicists: the first on installation, the second after 3 months, the final visit just prior to the end of the manufacturers warranty. The second test is only performed if any aspect of performance requires rechecking as a result of the first. Acceptance test protocols are based on those published by the Institute of Physical Sciences in Medicine. Details limiting values for the acceptance test measurements are given. In some instances testing has resulted in modifications to the design and construction of X-ray equipment. Acceptance testing is important in determining a baseline standard of performance against which routine quality assurance may be assessed. (author)

  8. The use of fuzzy logic in quality control testing of automotive and tractor equipment

    Directory of Open Access Journals (Sweden)

    Korobko А.

    2016-08-01

    Full Text Available The article analyzes the relevance of the research topics, defines goals and objectives, subject and object of research. On the basis of the literature analysis, the following eduction was made: not all the test methods in road and agricultural vehicles (tractors contribute to the effective implementation of the requirements of normative documents including international, inter-laboratory comparative tests. The approach in laboratory testing to the synthesis adaptive system of metrological assurance the use of fuzzy logic is proposed. These labs conduct testing of automotive and tractor equipment. The decision is under risk. The scheme of metrological assurance system covers all parties to ensure the necessary accuracy of measurements and tests; the necessary normative-technical documentation is provided; availability of measuring instruments and test equipment, standards and reference measures; availability of qualified personnel; the assurance that test results are accurate (correct and precision; provides effective decisions based on objective information.

  9. Dispensing Equipment Testing with Mid-Level Ethanol/Gasoline Test Fluid: Summary Report

    Energy Technology Data Exchange (ETDEWEB)

    Boyce, K.; Chapin, J. T.

    2010-11-01

    The National Renewable Energy Laboratory's (NREL) Nonpetroleum-Based Fuel Task addresses the hurdles to commercialization of biomass-derived fuels and fuel blends. One such hurdle is the unknown compatibility of new fuels with current infrastructure, such as the equipment used at service stations to dispense fuel into automobiles. The U.S. Department of Energy's (DOE) Vehicle Technology Program and the Biomass Program have engaged in a joint project to evaluate the potential for blending ethanol into gasoline at levels higher than nominal 10 volume percent. This project was established to help DOE and NREL better understand any potentially adverse impacts caused by a lack of knowledge about the compatibility of the dispensing equipment with ethanol blends higher than what the equipment was designed to dispense. This report provides data about the impact of introducing a gasoline with a higher volumetric ethanol content into service station dispensing equipment from a safety and a performance perspective.

  10. Outline of sodium-water reaction test in case of large leak with SWAT-3 testing equipments

    International Nuclear Information System (INIS)

    Sato, Minoru

    1978-01-01

    The key component in sodium-cooled fast reactors in steam generators, and the sodium-water reaction owing to the break of heating tubes may cause serious damages in equipments and pipings. The main factor controlling this phenomenon is the rate of leak of water. When the rate of water leak is small, the propagation of heating tube breaking may occur owing to ''wastage phenomenon'', on the other hand, when the rate of water leak is large, the phenomena of explosive pressure and flow occur due to the reaction heat and a large quantity of hydrogen generated by the reaction. In PNC, the testing equipments of SWAT-2 for small water leak and SWAT-1 for large leak were constructed, and the development test has been carried out to establish the method of safety design experimentally. The synthetic test equipment for the safety of steam generators, SWAT-3, was constructed to carry out the large water leak test in the scale close to actual plants. The object of the test, the outline of the test equipment, the phenomena of pressure and flow in the water injection test, the confirmation of the occurrence of secondary breaking of adjacent heating tubes, and the disposal of reaction products are described in this paper. This test is till going on, and the final conclusion will be reported later. (Kako, I.)

  11. Thermal fatigue equipment to test joints of materials for high heat flux components

    International Nuclear Information System (INIS)

    Visca, E.; Libera, S.; Orsini, A.; Riccardi, B.; Sacchetti, M.

    2000-01-01

    The activity, carried out in the framework of an ITER divertor task, was aimed at defining a suitable method in order to qualify junctions between armour materials and heat sink of plasma-facing components (PFCs) mock-ups. An equipment able to perform thermal fatigue testing by electrical heating and active water-cooling was constructed and a standard for the sample was defined. In this equipment, during operation cycles, two samples are heated by thermal contact up to a relevant temperature value (350 deg. C) and then the water flow is switched on, thus producing fast cooling with time constants and gradients close to the real operating conditions. The equipment works with a test cycle of about 60 s and is suitable for continuous operation. A complete test consists of about 10000 cycles. After the assembling, the equipment and the control software were optimized to obtain a good reliability. Preliminary tests on mock-ups with flat CFC tiles joined to copper heat sink were performed. Finite-elements calculations were carried out in order to estimate the value of the thermal stresses arising close to the joint under the transient conditions that are characteristic of this equipment

  12. Radiation protection type testing and licensing of diagnostic X-ray equipment in the GDR

    International Nuclear Information System (INIS)

    Taschner, P.; Poulheim, K.F.; Feldheim, W.

    1987-01-01

    The results of more than 10 years experience in type testing and type licensing of diagnostic X-ray equipment with respect to meeting radiation protection requirements as well as the implications for the conduct of these procedures resulting from the introduction of new radiation protection legislation in 1983 and 1984, are described. At present an updated version of the 'Regulation of 16 December 1977 concerning radiation protection type testing and licensing of sealed radiation sources and equipment emitting ionizing radiation' is being prepared. (author)

  13. Dynamic characteristics of lead rubber bearings with dynamic two-dimensional test equipment

    International Nuclear Information System (INIS)

    Ohtori, Y.; Ishida, K.; Mazda, T.

    1994-01-01

    Although studies have previously been done on the static mechanical properties of lead rubber bearings, this study aims to grasp the dynamic characteristics of lead rubber bearings from experimental results, using two-dimensional dynamic test equipment which is designed to grasp in detail such dynamic characteristics as deformation capacity and proof stress. This paper describes the results from three types of tests: (1) dynamic mechanical properties tests, (2) cyclic loading tests, and (3) dynamic ultimate tests. Through these tests, it was confirmed that the dynamic characteristics of lead rubber bearings are independent of strain rate

  14. Development of the testing procedure for units and elements of mining equipment

    Directory of Open Access Journals (Sweden)

    P. B. Gerike

    2017-09-01

    Full Text Available The author considers in detail the stages of creating a testing procedure for mining equipment based on the complex implementation of principles of nondestructive testing and technical diagnostics. The author substantiates effectiveness of application of a complex diagnostic approach for assessing the state of metal structures and energy-mechanical equipment of mining machines. The opportunity for timely detection of defects, regardless of their type and degree of danger, presents itself only with a wide application of the modern methods of vibration diagnostics and nondestructive testing. The author substantiates the effectiveness of specific combination of methods of nondestructive testing, most optimally suited for solving given tasks. The article contains the developed complex of more than 120 diagnostic rules, suitable for performing automated analysis of vibroacoustic signal and revealing the main damages of energy-mechanical equipment based on selective groups of informative frequencies. The author formulates the main criteria that one can use as a basic platform for improving the methodology for normalizing the parameters of mechanical oscillations. The developed diagnostic criteria became a basis for the development of individual spectral masks suitable for performing the analysis of parameters of vibroacoustic waves generated during operation of mining equipment. The author proves necessity of transition of repair and maintenance divisions of industrial enterprises to the system of maintenance of machinery according to its actual technical state, and the developed complex of diagnostic rules for detecting defects can serve as a platform for the implementation of basic elements of this system. The author substantiates the principal validity of the developed methodology for testing mining machines equipment and its individual elements, such as the predictive modeling of degradation of technical state of mining equipment and the

  15. Study to Analyze the Acquisition of Automatic Test Equipment (ATE) Systems. Data Sequence Number A003

    Science.gov (United States)

    1973-12-27

    Systems Test Equipment Comparator, ASTEC ) at NAEC can provide a very accurate Ion a pin by pin basis) match between the UUT and ATE in their data bank...In addition, abbreviated summary data on the ATE is also available to users. ASTEC will also file the UUT data as part of its data bank so that

  16. 76 FR 77914 - Energy Conservation Program for Certain Commercial and Industrial Equipment: Test Procedures for...

    Science.gov (United States)

    2011-12-15

    ... lifetime. Correlated color temperature (CCT) and color rendering index (CRI) would also be measured as potential means to delineate equipment classes for HID lamps. This notice of proposed rulemaking (NOPR) also... Conditions a. Ambient Conditions i. Ambient Test Temperature ii. Air Speed b. Power Supply Characteristics i...

  17. 40 CFR 1065.910 - PEMS auxiliary equipment for field testing.

    Science.gov (United States)

    2010-07-01

    ..., you may route engine intake air or exhaust through a flow meter. Route the engine intake air or exhaust as follows: (1) Flexible connections. Use short flexible connectors where necessary. (i) You may use flexible connectors to enlarge or reduce the pipe diameters to match that of your test equipment...

  18. RESUME95 Nordic field test of mobile equipment for nuclear fall-out monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Bourgeois, C.; Bresson, J.; Chiffot, T.; Guillot, L. [Centre d`Etudes de Valduc, Direction des Applications Militaires, Commissaiat a L`Energie Atomique, Tille (France)

    1997-12-31

    Nordic Safety Research (NKS) organised in August 1995 a field test of various techniques and instrumentation for monitoring radioactive fall-out. In an emergency situation, after a major release of radioactive material, many different measuring systems are going to be used, ranging from small hand hold intensitometer to complex spectrometer systems. In this test the following type of equipment were tested: Airborne spectrometers; Carborne spectrometers and dose rate meters; In situ spectrometers and intensitometers. Helinuc team was equipped of an airborne system and of a germanium device for in situ measurements. Different tasks were specified for each team: Mapping caesium fall-out and natural activity over two areas of 18 and 5 km{sup 2}; Research of hidden sources. For measurements and data processing the respect of time allowed was strictly controlled for testing the ability of each team. (au).

  19. RESUME95 Nordic field test of mobile equipment for nuclear fall-out monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Bourgeois, C; Bresson, J; Chiffot, T; Guillot, L [Centre d` Etudes de Valduc, Direction des Applications Militaires, Commissaiat a L` Energie Atomique, Tille (France)

    1998-12-31

    Nordic Safety Research (NKS) organised in August 1995 a field test of various techniques and instrumentation for monitoring radioactive fall-out. In an emergency situation, after a major release of radioactive material, many different measuring systems are going to be used, ranging from small hand hold intensitometer to complex spectrometer systems. In this test the following type of equipment were tested: Airborne spectrometers; Carborne spectrometers and dose rate meters; In situ spectrometers and intensitometers. Helinuc team was equipped of an airborne system and of a germanium device for in situ measurements. Different tasks were specified for each team: Mapping caesium fall-out and natural activity over two areas of 18 and 5 km{sup 2}; Research of hidden sources. For measurements and data processing the respect of time allowed was strictly controlled for testing the ability of each team. (au).

  20. Handling and disposal of SP-100 ground test nuclear fuel and equipment

    International Nuclear Information System (INIS)

    Wilson, C.E.; Potter, J.D.; Hodgson, R.D.

    1990-05-01

    The post SP-100 reactor testing period will focus on defueling the reactor, packaging the various radioactive waste forms, and shipping this material to the appropriate locations. Remote-handling techniques will be developed to defuel the reactor. Packaging the spent fuel and activated reactor components is a challenge in itself. This paper presents an overview of the strategy, methods, and equipment that will be used during the closeout phase of nuclear testing

  1. Handling and disposal of SP-100 ground test nuclear fuel and equipment

    International Nuclear Information System (INIS)

    Wilson, C.E.; Potter, J.D.; Hodgson, R.D.

    1991-01-01

    The post SP-100 reactor testing period will focus on defueling the reactor, packaging the various radiactive waste forms, and shipping this material to the appropriate locations. Remote-handling techniques will be developed to defuel the reactor. Packaging the spent fuel and activated reactor components is a challenge in itself. This paper presents an overview of the strategy, methods, and equipment that will be used during the closeout phase of nuclear testing

  2. TANK 18 AND 19-F TIER 1A EQUIPMENT FILL MOCK UP TEST SUMMARY

    Energy Technology Data Exchange (ETDEWEB)

    Stefanko, D.; Langton, C.

    2011-11-04

    The United States Department of Energy (US DOE) has determined that Tanks 18-F and 19-F have met the F-Tank Farm (FTF) General Closure Plan Requirements and are ready to be permanently closed. The high-level waste (HLW) tanks have been isolated from FTF facilities. To complete operational closure they will be filled with grout for the purpose of: (1) physically stabilizing the tanks, (2) limiting/eliminating vertical pathways to residual waste, (3) discouraging future intrusion, and (4) providing an alkaline, chemical reducing environment within the closure boundary to control speciation and solubility of select radionuclides. Bulk waste removal and heel removal equipment remain in Tanks 18-F and 19-F. This equipment includes the Advance Design Mixer Pump (ADMP), transfer pumps, transfer jets, standard slurry mixer pumps, equipment-support masts, sampling masts, dip tube assemblies and robotic crawlers. The present Tank 18 and 19-F closure strategy is to grout the equipment in place and eliminate vertical pathways by filling voids in the equipment to vertical fast pathways and water infiltration. The mock-up tests described in this report were intended to address placement issues identified for grouting the equipment that will be left in Tank 18-F and Tank 19-F. The Tank 18-F and 19-F closure strategy document states that one of the Performance Assessment (PA) requirements for a closed tank is that equipment remaining in the tank be filled to the extent practical and that vertical flow paths 1 inch and larger be grouted. The specific objectives of the Tier 1A equipment grout mock-up testing include: (1) Identifying the most limiting equipment configurations with respect to internal void space filling; (2) Specifying and constructing initial test geometries and forms that represent scaled boundary conditions; (3) Identifying a target grout rheology for evaluation in the scaled mock-up configurations; (4) Scaling-up production of a grout mix with the target rheology

  3. Soundness confirmation through cold test of the system equipment of HTTR

    International Nuclear Information System (INIS)

    Ono, Masato; Shinohara, Masanori; Iigaki, Kazuhiko; Tochio, Daisuke; Nakagawa, Shigeaki; Shimazaki, Yosuke

    2014-01-01

    HTTR was established at the Oarai Research and Development Center of Japan Atomic Energy Agency, for the purpose of the establishment and upgrading of high-temperature gas-cooled reactor technology infrastructure. Currently, it performs a safety demonstration test in order to demonstrate the safety inherent in high-temperature gas-cooled reactor. After the Great East Japan Earthquake, it conducted confirmation test for the purpose of soundness survey of facilities and equipment, and it confirmed that the soundness of the equipment was maintained. After two years from the confirmation test, it has not been confirmed whether the function of dynamic equipment and the soundness such as the airtightness of pipes and containers are maintained after receiving the influence of damage or deterioration caused by aftershocks generated during two years or aging. To confirm the soundness of these facilities, operation under cold state was conducted, and the obtained plant data was compared with confirmation test data to evaluate the presence of abnormality. In addition, in order to confirm through cold test the damage due to aftershocks and degradation due to aging, the plant data to compare was supposed to be the confirmation test data, and the evaluation on abnormality of the plant data of machine starting time and normal operation data was performed. (A.O.)

  4. Coating and Interface Degradation of Coated steel, Part 2: Accelerated Laboratory Tests

    International Nuclear Information System (INIS)

    Cambier, S.M.; Frankel, G.S.

    2014-01-01

    In a previous paper, it was demonstrated that the measurement of cathodic delamination by the Scanning Kelvin Probe can assess the interface stability of poly(vinyl butyral) (PVB) coated steel after field exposure. This technique was utilized to characterize the degradation of the polymer/metal interface in several outdoor climates. In this paper, the effects of environmental factors on the interface degradation were investigated in the laboratory. The mechanisms measured in the field were reproduced to provide input in the development of an appropriate accelerated test for PVB coated steel. The ASTM B117 and G154 standardized tests were investigated individually and sequentially. The interface stability improved after 24 h of ASTM G154 exposure. After 144 h of exposure to ASTM G154 exposure, polymer oxidation took place simultaneously with interface degradation. The condensation phase of the ASTM G154 test was responsible for the interface improvement while the ultraviolet radiation triggered the interface degradation. Pre-exposure to ASTM G154 delayed wet de-adhesion during ASTM B117 exposure. After wet de-adhesion caused by 6 h of ASTM B117, exposure to ASTM G154 for 24 h increased the interface stability. The effects of ultraviolet radiation, relative humidity, temperature and environment on interface degradation were investigated in a special chamber. Humidity was the primary factor found to influence the interface improvement during G154 exposure. A wet/dry salt fog cycle with irradiation by an ultraviolet or filtered xenon arc lamp around room temperature was suggested to reproduce the competition between the interface improvement and the interface degradation that takes place in the field

  5. A Cross-Cultural Test of the Work-Family Interface in 48 Countries

    Science.gov (United States)

    Jeffrey Hill, E.; Yang, Chongming; Hawkins, Alan J.; Ferris, Maria

    2004-01-01

    This study tests a cross-cultural model of the work-family interface. Using multigroup structural equation modeling with IBM survey responses from 48 countries (N= 25,380), results show that the same work-family interface model that fits the data globally also fits the data in a four-group model composed of culturally related groups of countries,…

  6. Potentialities of fluorography in radiographic testing of nuclear power plant equipment

    International Nuclear Information System (INIS)

    Gromov, Yu.V.; Kapustin, V.I.

    1984-01-01

    Results of fluorography of steel 5-250 mm thick with the application of different radiation sources in accordance with existing test requirements and standards for NPP equipment under industrial conditions, are presented. Sensitivity curves of fluorographic and radiographic testing methods using the RUP-150/300-10 X-ray device, LUEh-15-15000 D linear accelerator flaw detectors with 192 Yr, 60 Co, 137 Cs sources, are given. The radiation energy range is 24O keV-8 MeV. It is shown that fluorographic method meets the requirements of sensitivity and is recommended to test welded joints 5-220 mm thick in NPP equipment under laboratory and industrial conditions

  7. Technical manual: operation and equipment instructions for in situ impulse test

    International Nuclear Information System (INIS)

    1979-11-01

    This manual describes the test equipment and procedures for a new field test which determines the shear modulus of a soil deposit at strain levels equivalent to those experienced during actual earthquakes. Results from this test are typically used as input parameters to response analyses for evaluating local soil effects during earthquake shaking. The test employs a cross-hole wave propagation procedure with velocity transducers located in closely spaced adjacent borings. Clear, consistent, and repeatable data in all types of soil and a method of data reduction different from conventional geophysical first arrival techniques are unique aspects of this new test. In addition to describing the principles of the test and data reduction procedures, major discussions of the field procedures are also included. Detailed drilling and testing information is provided both for planning and executing a test program

  8. Results from the Operational Testing of the Eaton Smart Grid Capable Electric Vehicle Supply Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, Brion [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2014-10-01

    The Idaho National Laboratory conducted testing and analysis of the Eaton smart grid capable electric vehicle supply equipment (EVSE), which was a deliverable from Eaton for the U.S. Department of Energy FOA-554. The Idaho National Laboratory has extensive knowledge and experience in testing advanced conductive and wireless charging systems though INL’s support of the U.S. Department of Energy’s Advanced Vehicle Testing Activity. This document details the findings from the EVSE operational testing conducted at the Idaho National Laboratory on the Eaton smart grid capable EVSE. The testing conducted on the EVSE included energy efficiency testing, SAE J1772 functionality testing, abnormal conditions testing, and charging of a plug-in vehicle.

  9. Results from Operational Testing of the Siemens Smart Grid-Capable Electric Vehicle Supply Equipment

    Energy Technology Data Exchange (ETDEWEB)

    Bennett, Brion [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2015-05-01

    The Idaho National Laboratory conducted testing and analysis of the Siemens smart grid capable electric vehicle supply equipment (EVSE), which was a deliverable from Siemens for the U.S. Department of Energy FOA-554. The Idaho National Laboratory has extensive knowledge and experience in testing advanced conductive and wireless charging systems though INL’s support of the U.S. Department of Energy’s Advanced Vehicle Testing Activity. This document details the findings from the EVSE operational testing conducted at the Idaho National Laboratory on the Siemens smart grid capable EVSE. The testing conducted on the EVSE included energy efficiency testing, SAE J1772 functionality testing, abnormal conditions testing, and charging of a plug-in vehicle.

  10. Test method research on weakening interface strength of steel - concrete under cyclic loading

    Science.gov (United States)

    Liu, Ming-wei; Zhang, Fang-hua; Su, Guang-quan

    2018-02-01

    The mechanical properties of steel - concrete interface under cyclic loading are the key factors affecting the rule of horizontal load transfer, the calculation of bearing capacity and cumulative horizontal deformation. Cyclic shear test is an effective method to study the strength reduction of steel - concrete interface. A test system composed of large repeated direct shear test instrument, hydraulic servo system, data acquisition system, test control software system and so on is independently designed, and a set of test method, including the specimen preparation, the instrument preparation, the loading method and so on, is put forward. By listing a set of test results, the validity of the test method is verified. The test system and the test method based on it provide a reference for the experimental study on mechanical properties of steel - concrete interface.

  11. Real-Time Extended Interface Automata for Software Testing Cases Generation

    Directory of Open Access Journals (Sweden)

    Shunkun Yang

    2014-01-01

    Full Text Available Testing and verification of the interface between software components are particularly important due to the large number of complex interactions, which requires the traditional modeling languages to overcome the existing shortcomings in the aspects of temporal information description and software testing input controlling. This paper presents the real-time extended interface automata (RTEIA which adds clearer and more detailed temporal information description by the application of time words. We also establish the input interface automaton for every input in order to solve the problems of input controlling and interface covering nimbly when applied in the software testing field. Detailed definitions of the RTEIA and the testing cases generation algorithm are provided in this paper. The feasibility and efficiency of this method have been verified in the testing of one real aircraft braking system.

  12. Real-Time Extended Interface Automata for Software Testing Cases Generation

    Science.gov (United States)

    Yang, Shunkun; Xu, Jiaqi; Man, Tianlong; Liu, Bin

    2014-01-01

    Testing and verification of the interface between software components are particularly important due to the large number of complex interactions, which requires the traditional modeling languages to overcome the existing shortcomings in the aspects of temporal information description and software testing input controlling. This paper presents the real-time extended interface automata (RTEIA) which adds clearer and more detailed temporal information description by the application of time words. We also establish the input interface automaton for every input in order to solve the problems of input controlling and interface covering nimbly when applied in the software testing field. Detailed definitions of the RTEIA and the testing cases generation algorithm are provided in this paper. The feasibility and efficiency of this method have been verified in the testing of one real aircraft braking system. PMID:24892080

  13. The Variation Test and Extraction Equipment to Optimum Asphalt by Using Gasoline Solvent

    Science.gov (United States)

    Soehardi, Fitridawati

    2017-12-01

    Based on the Binamarga Specification 2010 at third revision, the extraction test should be carried out using the specimen from the loose asphalt mixture extracted from the back of the finisher bitumen machine. The purpose of this research is to find out the result of pretest and posttest extraction asphalt content. The Extraction test using two equipment, they are Soklet and Centrifuge. The specimens was used AMP, Asphalt Finisher and Core, which involved gasoline solvent. Based on the asphalt level extraction test results, the appropriate equipment was used centrifuge with the level accuracy as requirement of Binamarga Specification 2010 at third revision and the level of ease used as equipment in the field study. The asphalt content obtained for AMP 5,51%, Asphalt Finisher5,46% and Core 5.34%. As for the socket asphalt content obtained is AMP 5.55%, Asphalt Finisher 5.50% and Core core 5. 41%. The extract test value of asphalt content decreased, so it can be formulated KA JMF value of Job mix used was 5.56% with the tolerance given according to Binamarga Specification 2010 at third revision is ± 0.30%. In accordance with the results obtained then the results of a centrifuge tool that matches and meets the requirements of time, accuracy of results and economic value.

  14. Retrofit of waste-to-energy facilities equipped with electrostatic precipitators. Volume III: Test protocol

    Energy Technology Data Exchange (ETDEWEB)

    Rigo, H.G. [Rigo & Rigo Associates, Inc., Berea, OH (US); Chandler, A.J. [A.J. Chandler & Associates, Inc., Toronto, Ontario (Canada)

    1996-04-01

    The American Society of Mechanical Engineers' [ASME] Center for Research and Technology Development [CRTD] has been awarded a subcontract by the National Renewable Energy Laboratory [NREL] to demonstrate the technical performance and viability of flue gas temperature control in combination with dry acid gas reagent and activated carbon injection at an existing electrostatic precipitator [ESP] equipped municipal waste combustor [MWC]. The objective of this proof-of-concept demonstration test is to economically and reliably meet 40 CFR 60 Subpart Cb Emissions Guidelines for MWC's at existing ESP equipped facilities. The effort is being directed by a Subcommittee of tile ASME Research Committee on Industrial and Municipal Wastes [RCIMW] chaired by Dave Hoecke. Mr. Greg Barthold of ASME/CRTD is the Project Manager. ASME/CRTD contracted with Rigo & Rigo Associates, Inc. in cooperation with A.J. Chandler & Associates, Ltd. to be the Principal Investigator for the project and manage the day-t o-day aspects of the program, conduct the testing reduce and interpret the data and prepare the report. Testing will be conducted at the 2 by 210 TPD, ESP equipped MWC at the Davis County Resource Recovery Facility in Layton, Utah. The test plan calls for duplicate metals (Cd, Pb and Hg), dioxin and acid gas runs.

  15. Evaluation of protection factor of respiratory protective equipment using indigenously developed protection factor test facility

    International Nuclear Information System (INIS)

    Patkulkar, D.S.; Ganesh, G.; Tripathi, R.M.

    2018-01-01

    Assigned protection factor (APF) is an indicator representing effectiveness of a respirator and it provides workplace level of respiratory protection for workers in providing protection against exposure to airborne contaminants Occupational Safety and Health Administration (OSHA) specifies 'Respirator APF' and 'Maximum Use Concentration' (MUC - a term derived using APF) shall be an integral part of Respirator Protection Standard. MUC establishes the maximum airborne concentration of a contaminant in which a respirator with a given APF may be used. The use of particulate respirators such as half face mask, full face mask and powered air purifying respirators is essential for radioactive jobs in nuclear facilities to prevent any intake of radionuclide. With this impetus, the Protection Factor Test Facility (PFTF) for testing and evaluation of respiratory protective equipment meeting relevant applicable standards was designed, fabricated and installed in Respiratory Protective Equipment Laboratory of Health Physics Division

  16. Progress in the integration of Test Blanket Systems in ITER equatorial port cells and in the interfaces definition

    Energy Technology Data Exchange (ETDEWEB)

    Pascal, R., E-mail: romain.pascal@iter.org [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Beloglazov, S.; Bonagiri, S. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Commin, L. [CEA, IRFM, Cadarache (France); Cortes, P.; Giancarli, L.M.; Gliss, C.; Iseli, M.; Lanza, R.; Levesy, B.; Martins, J.-P. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Neviere, J.-C. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Comex-Nucleaire, 13115 Saint Paul Lez Durance (France); Patisson, L.; Plutino, D.; Shu, W. [ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance (France); Swami, H.L. [Institute for Plasma Research, Bhat, Gandhinagar 382428 (India)

    2012-08-15

    Highlights: Black-Right-Pointing-Pointer The design integration of two test blanket systems in ITER port cell is addressed. Black-Right-Pointing-Pointer Definition of interfaces of TBSs with building and other ITER systems is done. Black-Right-Pointing-Pointer Designs of pipe forest, bioshield plug and ancillary equipment unit are described. Black-Right-Pointing-Pointer The maintenance of the two test blanket systems in ITER port cell is considered. Black-Right-Pointing-Pointer The management of the heat and tritium releases in the TBM port cell is described. - Abstract: In the framework of the TBM Program, three ITER vacuum vessel equatorial ports (no. 16, no. 18 and no. 02) have been allocated for the testing of up to six mock-ups of six different DEMO tritium breeding blankets. Each one is called a Test Blanket System (TBS). A TBS consists mainly of the Test Blanket Module (TBM), the in-vessel component facing the plasma, and several ancillary systems, in particular the cooling system and the tritium extraction system. Each port accommodates two TBMs and therefore the two TBSs have to share the corresponding port cell. This paper deals with the design integration aspects of the two TBSs in each port cell performed at ITER Organization (IO) with the corresponding definition of interfaces with other ITER systems. The performed activities have raised several issues that are discussed in the paper and for which design solutions are proposed.

  17. Application of new technologies for the nondestructive testing equipment Novovoronezh NPP-2 and Leningrad 2

    International Nuclear Information System (INIS)

    Nichev, V.; Cvitanović, M.; Nadinic, B.

    2016-01-01

    This presentation demonstrates the latest technology and means of nondestructive testing of equipment of reactor VVER-1200, realized at the Novovoronezh NPP-2 and Leningrad NPP-2. The developments are based on a contract between ATOMKOMPLEKT with HRID, Croatia as a designer and contractor and and Rosatom. The activities of the presented company and IQC are associated with the qualification of methodologies control of components important to safety as required by the European methodology and requirements of Russian legislation

  18. Performance Test of the Salt transfer and Pellet fabrication of UCl3 Making Equipment for Electrorefining

    International Nuclear Information System (INIS)

    Woo, M. S.; Jin, H. J.; Park, G. I.; Park, S. B.

    2014-01-01

    The process to produce a uranium chloride salt includes two steps: a reaction process of gaseous chlorine with liquid cadmium to form the CdCl 2 occurring in a Cd layer, followed by a process to produce UCl 3 by the reaction of U in the LiCl-KCl eutectic salt and CdCl 2 . Chemical reaction is next chlorination reaction; - Cd chlorination : Cd + Cl2 → CdCl 2 - U chlorination : 3CdCl2 + 2U → 3Cd + 2UCl 3 The apparatus for producing UCl 3 consists of a chlorine gas generator, a uranium chlorinator, a Cd distiller, the pelletizer, a off-gas wet scrubber and a dry scrubber. Salt transfer system set among reactors to transfer salt at 500 .deg. C. The temperature of the reactants is maintained at about 600 .deg. C. After the reaction is completed in the uranium chlorinator, The Salt product is transferred to the Cd distiller to decrease residual Cd concentration in the salts, and then salt is transferred to the mould of pelletizer by a transfer system to fabricate pellet type salt. Performance test of the salt transfer and pellet fabrication of its equipment was tested in this work. Performance test of the salt transfer and pellet fabrication of UCl3 making equipment for Electrorefining carried out in this work. The result of equipment test is that melted salt at 600 .deg. C was easy transferred by salt transfer equipment heated at 500 .deg. C. In this time, salt transfer was carried out by argon gas pressurization at 3bar. When velocity of salt transfer was controlled under reduce pressure, velocity of salt transfer was difficult to control. And when salt pellet was fabricated by the mold of pelletizer heated at 90 .deg. C better than mold of pelletizer heated at 200 .deg. C because salt melted prevent leakage from mold of pelletizer

  19. Spaceport Command and Control System User Interface Testing

    Science.gov (United States)

    Huesman, Jacob

    2016-01-01

    The Spaceport Command and Control System will be the National Aeronautics and Space Administration's newest system for launching commercial and government owned spacecraft. It's a large system with many parts all in need of testing. To improve upon testing already done by NASA engineers, the Engineering Directorate, Electrical Division (NE-E) of Kennedy Space Center has hired a group of interns each of the last few semesters to develop novel ways of improving the testing process.

  20. Molten Salt Test Loop (MSTL) system customer interface document.

    Energy Technology Data Exchange (ETDEWEB)

    Gill, David Dennis; Kolb, William J.; Briggs, Ronald D.

    2013-09-01

    The National Solar Thermal Test Facility at Sandia National Laboratories has a unique test capability called the Molten Salt Test Loop (MSTL) system. MSTL is a test capability that allows customers and researchers to test components in flowing, molten nitrate salt. The components tested can range from materials samples, to individual components such as flex hoses, ball joints, and valves, up to full solar collecting systems such as central receiver panels, parabolic troughs, or linear Fresnel systems. MSTL provides realistic conditions similar to a portion of a concentrating solar power facility. The facility currently uses 60/40 nitrate %E2%80%9Csolar salt%E2%80%9D and can circulate the salt at pressure up to 40 bar (600psi), temperature to 585%C2%B0C, and flow rate of 44-50kg/s(400-600GPM) depending on temperature. The purpose of this document is to provide a basis for customers to evaluate the applicability to their testing needs, and to provide an outline of expectations for conducting testing on MSTL. The document can serve as the basis for testing agreements including Work for Others (WFO) and Cooperative Research and Development Agreements (CRADA). While this document provides the basis for these agreements and describes some of the requirements for testing using MSTL and on the site at Sandia, the document is not sufficient by itself as a test agreement. The document, however, does provide customers with a uniform set of information to begin the test planning process.

  1. Thermal vacuum test of space equipment: tests of SIR-2 instrument Chandrayaan-1 mission

    Science.gov (United States)

    Sitek, P.

    2008-11-01

    We describe the reasons of proceeding Thermal-Vacuum tests for space electronic. We will answer on following questions: why teams are doing TV tests, what kind of phases should be simulated, which situations are the most critical during TV tests, what kind of results should be expected, which errors can be detect. As an example, will be shown TV-test of SIR-2 instrument for Chandrayaan-1 moon mission.

  2. Large Scale Leach Test Facility: Development of equipment and methods, and comparison to MCC-1 leach tests

    International Nuclear Information System (INIS)

    Pellarin, D.J.; Bickford, D.F.

    1985-01-01

    This report describes the test equipment and methods, and documents the results of the first large-scale MCC-1 experiments in the Large Scale Leach Test Facility (LSLTF). Two experiments were performed using 1-ft-long samples sectioned from the middle of canister MS-11. The leachant used in the experiments was ultrapure deionized water - an aggressive and well characterized leachant providing high sensitivity for liquid sample analyses. All the original test plan objectives have been successfully met. Equipment and procedures have been developed for large-sample-size leach testing. The statistical reliability of the method has been determined, and ''bench mark'' data developed to relate small scale leach testing to full size waste forms. The facility is unique, and provides sampling reliability and flexibility not possible in smaller laboratory scale tests. Future use of this facility should simplify and accelerate the development of leaching models and repository specific data. The factor of less than 3 for leachability, corresponding to a 200,000/1 increase in sample volume, enhances the credibility of small scale test data which precedes this work, and supports the ability of the DWPF waste form to meet repository criteria

  3. Seismic proving tests on the reliability for large components and equipment of nuclear power plants

    International Nuclear Information System (INIS)

    Ohno, Tokue; Tanaka, Nagatoshi

    1988-01-01

    Since Japan has destructive earthquakes frequently, the structural reliability for large components and equipment of nuclear power plants are rigorously required. They are designed using sophisticated seismic analyses and have not yet encountered a destructive earthquake. When nuclear power plants are planned, it is very important that the general public understand the structural reliability during and after an earthquake. Seismic Proving Tests have been planned by Ministry of International Trade and Industry (Miti) to comply with public requirement in Japan. A large-scale high-performance vibration table was constructed at Tasted Engineering Laboratory of Nuclear Power Engineering Test Center (NU PEC), in order to prove the structural reliability by vibrating the test model (of full scale or close to the actual size) in the condition of a destructive earthquake. As for the test models, the following four items were selected out of large components and equipment important to the safety: Reactor Containment Vessel; Primary Coolant Loop or Primary Loop Recirculation System; Reactor Pressure Vessel; and Reactor Core Internals. Here is described a brief of the vibration table, the test method and the results of the tests on PWR Reactor Containment Vessel and BWR Primary Loop Recirculation System (author)

  4. A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry

    International Nuclear Information System (INIS)

    Dong, Kyung Rae; Kim, Ho Sung; Jung, Woon Kwan

    2008-01-01

    =0.96), P2 - (spine: 0.002±0.018 g/cm 2 , %CV=0.55, Femur: 0.001±0.013 g/cm 2 , %CV=0.48) in Group 3. The average error±2SD, %CV, and r value was spine : 0.006±0.024 g/cm 2 , %CV=0.86, r=0.995, Femur: 0±0.014 g/cm 2 , %CV=0.54, r=0.998 in Group 4. Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of ±2% defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  5. A Study of Equipment Accuracy and Test Precision in Dual Energy X-ray Absorptiometry

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Kyung Rae [Dept. of Radiological Technology, Gwangju Health College, Gwangju (Korea, Republic of); Kim, Ho Sung [Dept. of Nuclear Medicine, Asan Medical Center, Seoul (Korea, Republic of); Jung, Woon Kwan [Dept. of Nuclear Energy Technology, Chosun University, Gwangju (Korea, Republic of)

    2008-03-15

    .94, Femur: 0.001{+-}0.019 g/cm{sup 2}, %CV=0.96), P2 - (spine: 0.002{+-}0.018 g/cm{sup 2}, %CV=0.55, Femur: 0.001{+-}0.013 g/cm{sup 2}, %CV=0.48) in Group 3. The average error{+-}2SD, %CV, and r value was spine : 0.006{+-}0.024 g/cm{sup 2}, %CV=0.86, r=0.995, Femur: 0{+-}0.014 g/cm{sup 2}, %CV=0.54, r=0.998 in Group 4. Both LUNAR ASP CV% and HOLOGIC Spine Phantom are included in the normal range of error of {+-}2% defined in ISCD. BMD measurement keeps a relatively constant value, so showing excellent repeatability. The Phantom has homogeneous characteristics, but it has limitations to reflect the clinical part including variations in patient's body weight or body fat. As a result, it is believed that quality control using Phantom will be useful to check mis-calibration of the equipment used. A value measured a patient two times with one equipment, and that of double-crossed two equipment are all included within 2SD Value in the Bland - Altman Graph compared results of Group 3 with Group 4. The r value of 0.99 or higher in Linear regression analysis(Regression Analysis) indicated high precision and correlation. Therefore, it revealed that two compatible equipment did not affect in tracking the patients. Regular testing equipment and capabilities of a tester, then appropriate calibration will have to be achieved in order to calculate confidential BMD.

  6. Interfacing and data acquisitioning of creep testing machines

    International Nuclear Information System (INIS)

    Rana, M.A.; Ahmad, Z.; Farooq, M.A.; Ali, L.; Mushtaq, N.

    1998-05-01

    Automation of DSM-6100-CREEP TESTING MACHINES is made by using an IBM PC/XT/AT compatibles along with DAS-16 High Speed Analog I/O board. Creep test parameters namely force, temperature and LVDTs (Linear Variable Differential Transducer) left and right are calibrated. Empirical formula for each parameter is developed to convert data, which is received in the form of counts, into engineering units. LVDT controller module is designed and fabricated to handle two LVDTs for data acquisition of a creep test required for it. (author)

  7. Double-shell tank integrity assessments ultrasonic test equipment performance test

    Energy Technology Data Exchange (ETDEWEB)

    Pfluger, D.C.

    1996-09-26

    A double-shell tank (DST) inspection (DSTI) system was performance tested over three months until August 1995 at Pittsburgh, Pennsylvania, completing a contract initiated in February 1993 to design, fabricate, and test an ultrasonic inspection system intended to provide ultrasonic test (UT) and visual data to determine the integrity of 28 DSTs at Hanford. The DSTs are approximately one-million-gallon underground radioactive-waste storage tanks. The test was performed in accordance with a procedure (Jensen 1995) that included requirements described in the contract specification (Pfluger 1995). This report documents the results of tests conducted to evaluate the performance of the DSTI system against the requirements of the contract specification. The test of the DSTI system also reflects the performance of qualified personnel and operating procedures.

  8. The study of human bodies' impedance networks in testing leakage currents of electrical equipments

    Science.gov (United States)

    Zhang, Zhaohui; Wang, Xiaofei

    2006-11-01

    In the testing of electrical equipments' leakage currents, impedance networks of human bodies are used to simulate the current's effect on human bodies, and they are key to the preciseness of the testing result. This paper analyses and calculates three human bodies' impedance networks of measuring electric burn current, perception or reaction current, let-go current in IEC60990, by using Matlab, compares the research result of current effect thresholds' change with sine wave's frequency published in IEC479-2, and amends parameters of measuring networks. It also analyses the change of perception or reaction current with waveform by Multisim.

  9. Development of hot test equipment for advanced nuclear fuel cycle development in JNC

    International Nuclear Information System (INIS)

    Nomura, K.; Shibata, A.; Nemoto, S.; Aoshima, A.; Funasaka, H.

    2001-01-01

    JNC (Japan nuclear fuel cycle development institute) has been developing a mini centrifugal contactor. JNC has experience of the development of the RETF (Recycle equipment test facility; under construction at Tokai-works) type centrifugal contactor and the mini centrifugal contactor is designed on the basis of this knowledge. The followings were carried out in order to estimate the performance of the mini centrifugal contactor: functional test for evaluating basic performance of this extractor, acid-solvent test and uranium test for confirming that sufficient performance is attained. The results showed wide performance in comparison with the mini mixer settler used so far and it is expected that shortening in operating time and higher efficiency of extracting tests will be achieved. (author)

  10. Test module development to detect the flase call probe pins on microeprocessor test equipment

    Science.gov (United States)

    Tang, L. W.; Ong, N. R.; Mohamad, I. S. B.; Alcain, J. B.; Retnasamy, V.

    2017-09-01

    Probe pins are useful for electrical testing of microelectronic components, printed circuit board assembly (PCBA), microprocessors and other electronic devices due to it provides the conductivity test based on specific device circuit design. During the repeatable test runs, the load of test modules, contact failures and the current conductivity induces layer wear off all the tip of probe pins contact. Contamination will be build-up on probe pins and increased contact resistivity which results of cost loss and time loss for rectifying programs, rectifying testers and exchanging new probe pins. In this study, a resistivity approach will be developed to provide "Testing of Test Probes". The test module based on "Four-wire Ohm measurement" method with two alternative ways of applying power supply, that are 9V from a single power supply and 5V from Arduino UNO power supply were demonstrated to measure the small resistance value of microprocessor probe pin. A microcontroller with VEE Pro software was used to record the measurement data. The accuracy of both test modules were calibrated under different temperature conditions and result shows that 9V from a single power supply test module has higher measurement accuracy.

  11. Investigation of possible methods for equipment self-tests in digital radiology

    International Nuclear Information System (INIS)

    Zoetelief, J.; Idris, H. H. E.; Jansen, J. T. M.

    2005-01-01

    Quality control in digital radiology can be time-consuming. Equipment self-tests may significantly decrease staff workload. The two most essential parameters for radiology systems are image quality and patient dose. Concerning patient dose, information on the dose-area product (DAP) values generally forms the basis for assessment of patient dose. DAP-values can be measured using a transmission ionisation chamber or calculated from equipment settings. In the present study, various image quality parameters were derived using a contrast-detail (C-D) phantom. The investigation included a computer-aided assessment of C-D images, which produced various parameters, and also parameters based upon scoring by human observers. In addition, another parameter was calculated from modulation transfer function (MTF) measurements. The automatically calculated parameters showed good correlation with human readings, although the number of X-ray systems studied is still limited. We propose a combined evaluation of DAP and automatically calculated C-D or MTF parameters for equipment self-tests. (authors)

  12. Development of a model and test equipment for cold flow tests at 500 atm of small nuclear light bulb configurations

    Science.gov (United States)

    Jaminet, J. F.

    1972-01-01

    A model and test equipment were developed and cold-flow-tested at greater than 500 atm in preparation for future high-pressure rf plasma experiments and in-reactor tests with small nuclear light bulb configurations. With minor exceptions, the model chamber is similar in design and dimensions to a proposed in-reactor geometry for tests with fissioning uranium plasmas in the nuclear furnace. The model and the equipment were designed for use with the UARL 1.2-MW rf induction heater in tests with rf plasmas at pressures up to 500 atm. A series of cold-flow tests of the model was then conducted at pressures up to about 510 atm. At 504 atm, the flow rates of argon and cooling water were 3.35 liter/sec (STP) and 26 gal/min, respectively. It was demonstrated that the model is capable of being operated for extended periods at the 500-atm pressure level and is, therefore, ready for use in initial high-pressure rf plasma experiments.

  13. Toxicity testing of polymer materials for dialysis equipment: reconsidering in vivo testing.

    Science.gov (United States)

    Sauer, U G; Liebsch, M; Kolar, R

    2000-01-01

    In fulfilment of the aims of the European Union Biocidal Directive (Directive 98/8/EC), Technical Guidance Documents are currently being compiled. Part I of these Technical Guidance Documents covers data requirements for active substances and biocidal products. The Three Rs principle has been applied in certain parts of the toxicity and ecotoxicity testing scheme for pesticides, such as testing for acute oral toxicity, skin and eye irritation, skin sensitisation, and dermal absorption. Further recommendations on how to proceed with regard to the continuing replacement, reduction and refinement of animal experiments in this field of regulatory testing are included for consideration. In this context, besides stressing the necessity to validate and accept further alternatives, emphasis is placed on providing the possibility of waiving unnecessary tests and on the continuous evaluation of whether certain tests are needed at all. 2000 FRAME.

  14. Status of NRC approval of EPRI electromagnetic interference susceptibility testing guidelines for digital equipment

    International Nuclear Information System (INIS)

    James, R.W.; Shank, J.W.; Yoder, C.

    1996-01-01

    Historically, nuclear power plants installing digital equipment have been required to conduct expensive, site-specific electromagnetic interference (EMI) surveys to demonstrate that EMI will not affect the operation of sensitive electronic equipment. Consequently, EPRI formed a Utility Working Group which developed a set of generic EMI susceptibility testing guidelines, which were published as an EPRI report in September 1994. These guidelines are based upon EMI survey data obtained from several different plants and include criteria for determining their applicability. The Working Group interacted with NRC staff to obtain NRC approval. In April 1996, the NRC issued a Safety Evaluation Report (SER) endorsing the guidelines as a valid means of demonstrating EMI compatibility. The issuance of this SER was conditional on issuing a revision to the EPRI EMI Guidelines. This paper summarizes the guidelines, the NRC SER, and the current status of Revision 1 to the report

  15. Qualification test of Class 1E equipment based on IEEE323 Std 2003

    International Nuclear Information System (INIS)

    Kim, J. S.; Jung, S. C.; Kim, T. R.

    2004-01-01

    IEEE Standard for Qualifying Class 1E Equipment has been updated to 2003 edition since the issue of IEEE Std 323-1971, 1974, 1983. NRC approved the IEEE Std 323-1974 as Qualification standard of Class 1E Equipment in domestic nuclear power plant. IEEE Std 323-2003 was issued in September of 2003 and utility is waiting the approval of NRC. IEEE Std 323-2003 suggest a new qualification technique which adopts the condition monitoring. Performance of two transient during DBA test is no longer recommended in IEEE Std 323-2003. IEEE323 Std 2003 included a chapter of ''extension of Qualified life'' to make available the life extension of components during plant life extension. For the efficient control of preserving EQ in domestic nuclear power plant, IEEE323 Std 2003 is strongly recommended

  16. FED firmware interface testing with pixel phase 1 emulator

    CERN Document Server

    Kilpatrick, Matthew

    2017-01-01

    A hardware emulation of the CMS pixel detector phase 1 upgrade front-end electronics has been developed to test and validate the architecture of the back-end electronics (FED) firmware. The emulation is implemented on a Virtex 6 FPGA on the CERN GLIB uTCA platform, utilizing an 8-way SFP FPGA Mezzanine Card to drive compatible optical transmitters to the back-end electronics at 400 bps. The firmware emulates the complex functions of the phase 1 pixel readout chips (PSI46digv2 and PROC600) and token bit manager ASICs and allows for possible abnormalities that can occur in the output data stream. The emulation implements both fixed data patterns that are used as test vectors and realistic simulated data to drive the readout of the FED at the expected data and trigger rates. Testing software was developed to control the emulator and verify correct transmission of data and exception handling in the FED. An installation has been integrated into the pixel DAQ test system at CMS to be used for fast validation of F...

  17. FED firmware interface testing with pixel phase 1 emulator

    CERN Document Server

    Kilpatrick, Matthew

    2018-01-01

    A hardware emulation of the CMS pixel detector phase 1 upgrade front-end electronics has been developed to test and validate the architecture of the back-end electronics (FED) firmware. The emulation is implemented on a Virtex 6 FPGA on the CERN GLIB uTCA platform, utilizing an 8-way SFP FPGA Mezzanine Card to drive compatible optical transmitters to the back-end electronics at 400 bps. The firmware emulates the complex functions of the phase 1 pixel readout chips (PSI46digv2 and PROC600) and token bit manager ASICs and allows for possible abnormalities that can occur in the output data stream. The emulation implements both fixed data patterns that are used as test vectors and realistic simulated data to drive the readout of the FED at the expected data and trigger rates. Testing software was developed to control the emulator and verify correct transmission of data and exception handling in the FED. An installation has been integrated into the pixel DAQ test system at CMS to be used for fast validation of F...

  18. Server Interface Descriptions for Automated Testing of JavaScript Web Applications

    DEFF Research Database (Denmark)

    Jensen, Casper Svenning; Møller, Anders; Su, Zhendong

    2013-01-01

    Automated testing of JavaScript web applications is complicated by the communication with servers. Specifically, it is difficult to test the JavaScript code in isolation from the server code and database contents. We present a practical solution to this problem. First, we demonstrate that formal...... server interface descriptions are useful in automated testing of JavaScript web applications for separating the concerns of the client and the server. Second, to support the construction of server interface descriptions for existing applications, we introduce an effective inference technique that learns...... communication patterns from sample data. By incorporating interface descriptions into the testing tool Artemis, our experimental results show that we increase the level of automation for high-coverage testing on a collection of JavaScript web applications that exchange JSON data between the clients and servers...

  19. Presentation of accessibility equipment for primary pipings, IHX, pumps and appertaining manipulator tests

    International Nuclear Information System (INIS)

    Hahn, G.; Hoeft, E.

    1980-01-01

    Accessibility and inservice procedure of SNR-300 components are described. Due to the high radiation level in the primary system it was necessary to develop special equipment to permit access to the testing components. The pertinent examination methods for surveying welding seams are acoustic (ultrasonic) and optical procedures (TV cameras, surface crack tests). This can be done by remote-controlled manipulators and special devices, which can transport the inspection system by rails to the testing position. Presently, relatively limited experience exists for such remote-controlled handling in nuclear power plants. Thus model experiments were carried out on a model pipe section at INTERATOM. The performed test shows that the concept planned to perform inservice by using remote-controlled manipulators can be realized successfully. (author)

  20. 46 CFR 133.45 - Tests and inspections of lifesaving equipment and arrangements.

    Science.gov (United States)

    2010-10-01

    ... of flotation equipment such as lifebuoys, lifejackets, immersion suits, work vests, lifefloats... mechanisms; (3) The proper condition of flotation equipment such as lifebuoys, lifejackets, immersion suits, work vests, lifefloats, buoyant apparatus, and associated equipment; (4) That each inflatable liferaft...

  1. Ion chamber-electrometer measurement system for radiation protection tests in X-ray equipment for interventional procedures

    International Nuclear Information System (INIS)

    Bottaro, Marcio

    2012-01-01

    A new parallel plate ionization chamber with volume of 500 cc and an electrometer with digital interface for data acquisition, configuring an ion chamber electrometer measurement system, were developed to comply with specific requirements for compulsory radiation protection tests in interventional X-ray equipment. The ion chamber has as main characteristics: low cost, mechanical strength and response variation with beam energy of less than 5% in the 40 kV to 150 kV range. The electrometer has a high gain (5x10 8 V/A) transimpedance amplifier circuit and a data acquisition and control system developed in LabVIEW ® platform, including an integrated power supply for the ion chamber bias with adjustable DC voltage output from O to 1000 V and an air density correction system. Electric field calculations, laboratory measurements in standard beams and computational simulations of radiation interactions in chamber volume with Monte Carlo Method were employed in the elaborated methodology of the ion chamber development, which was tested and validated. It was also developed a simplified methodology for electrometer calibration that assures metrological trustworthiness of the measurement system. Tests for the system performance evaluation as environmental influence response, energy response, angular dependency, linearity and air kerma and air kerma rate dependency were performed according to international standards and requirements. Additionally, for a detailed evaluation of the developed ion chamber, simulations with various scattered radiation spectra were performed. The system was applied in leakage radiation, residual radiation and scattered radiation tests, being compared with other reference systems and validated for laboratorial test routine. (author)

  2. Development of an automatic test equipment for nano gauging displacement transducers

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Y-C [National Yunlin University of Science and Technology, Taiwan (China); Jywe, W-Y [National Formosa University, Taiwan (China); Liu, C-H [National Formosa University, Taiwan (China)

    2005-01-01

    In order to satisfy the increasing demands on the precision in manufacturing technology, nanaometrology gradually becomes more important in manufacturing process. To ensure the precision of manufacture, precise measuring instruments and sensors play a decisive role for the accurate characterization and inspection of products. For linear length inspection, high precision gauging displacement transducers, i.e. nano gauging displacement transducers (NGDT), have been often utilized, which have been often utilized, which have the resolution in the nanometer range and can achieve an accuracy of less than 100 nm. Such measurement instruments include transducers based on electronic as well as optical measurement principles, e.g. inductive, incremental-optical or interference optical. To guarantee the accuracy and the traceability to the definition of the meter, calibration and test of NGDT are essential. Currently, there are some methods and machines for test of NGDT, but they suffer from various disadvantages. Some of them permit only manual test procedures which are time-consuming, e.g. with high accurate gauge blocks as material measures. Other tests can reach higher accuracy only in the micrometer range or result in uncertainties of more than 100 nm in the large measuring ranges. To realize the test of NGDT with a high resolution as well as a large measuring range, an automatic test equipment was constructed, that has a resolution of 1.24 nm, a measuring range of up to 20 nm (60 mm) and a measuring uncertainty of approximate {+-}10 nm can fulfil the requirements of high resolution within the nanometer range while simultaneously covering a large measuring range in the order of millimeters. The test system includes a stable frame, a polarization interferometer, an angle sensor, an angular control, a drive system and piezo translators. During the test procedure, the angular control and piezo translators minimize the Abbe error. For the automation of the test procedure a

  3. Development of an automatic test equipment for nano gauging displacement transducers

    International Nuclear Information System (INIS)

    Wang, Y-C; Jywe, W-Y; Liu, C-H

    2005-01-01

    In order to satisfy the increasing demands on the precision in manufacturing technology, nanaometrology gradually becomes more important in manufacturing process. To ensure the precision of manufacture, precise measuring instruments and sensors play a decisive role for the accurate characterization and inspection of products. For linear length inspection, high precision gauging displacement transducers, i.e. nano gauging displacement transducers (NGDT), have been often utilized, which have been often utilized, which have the resolution in the nanometer range and can achieve an accuracy of less than 100 nm. Such measurement instruments include transducers based on electronic as well as optical measurement principles, e.g. inductive, incremental-optical or interference optical. To guarantee the accuracy and the traceability to the definition of the meter, calibration and test of NGDT are essential. Currently, there are some methods and machines for test of NGDT, but they suffer from various disadvantages. Some of them permit only manual test procedures which are time-consuming, e.g. with high accurate gauge blocks as material measures. Other tests can reach higher accuracy only in the micrometer range or result in uncertainties of more than 100 nm in the large measuring ranges. To realize the test of NGDT with a high resolution as well as a large measuring range, an automatic test equipment was constructed, that has a resolution of 1.24 nm, a measuring range of up to 20 nm (60 mm) and a measuring uncertainty of approximate ±10 nm can fulfil the requirements of high resolution within the nanometer range while simultaneously covering a large measuring range in the order of millimeters. The test system includes a stable frame, a polarization interferometer, an angle sensor, an angular control, a drive system and piezo translators. During the test procedure, the angular control and piezo translators minimize the Abbe error. For the automation of the test procedure a

  4. Development of an automatic test equipment for nano gauging displacement transducers

    Science.gov (United States)

    Wang, Yung-Chen; Jywe, Wen-Yuh; Liu, Chien-Hung

    2005-01-01

    In order to satisfy the increasing demands on the precision in manufacturing technology, nanaometrology gradually becomes more important in manufacturing process. To ensure the precision of manufacture, precise measuring instruments and sensors play a decesive role for the accurate characterization and inspection of products. For linear length inspection, high precision gauging displacement transducers, i.e. nano gauging displacement transducers (NGDT), have been often utilized, which have been often utilized, which have the resolution in the nanometer range and can achieve an accuracy of less than 100 nm. Such measurement instruments include transducers based on electronic as well as optical measurement principles, e.g. inductive, incremental-optical or interference optical. To guarantee the accuracy and the traceability to the definition of the meter, calibration and test of NGDT are essential. Currently, there are some methods and machines for test of NGDT, but they suffer from various disadvantages. Some of them permit only manual test procedures which are time-consuming, e.g. with high accurate gauge blocks as material measures. Other tests can reach higher accuracy only in the micrometer range or result in uncertainties of more than 100 nm in the large measuring ranges. To realize the test of NGDT with a high resolution as well as a large measuring range, an automatic test equipment was constructed, that has a resolution of 1.24 nm, a measuring range of up to 20 nm (60 mm) and a measuring uncertainty of approximate ±10 nm can fulfil the requirements of high resolution within the nanometer range while simultaneously covering a large measuring range in the order of millimeters. The test system includes a stable frame, a polarization interferometer, an angle sensor, an angular control, a drive system and piezo translators. During the test procedure, the angular control and piezo translators minimize the Abbe error. For the automation of the test procedure a

  5. Underground Test Area Activity Communication/Interface Plan, Nevada National Security Site, Nevada, Revision 0

    Energy Technology Data Exchange (ETDEWEB)

    Farnham, Irene [Navarro, Las Vegas, NV (United States); Rehfeldt, Kenneth [Navarro, Las Vegas, NV (United States)

    2016-10-01

    The purpose of this plan is to provide guidelines for effective communication and interfacing between Underground Test Area (UGTA) Activity participants, including the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office (NNSA/NFO) and its contractors. This plan specifically establishes the following: • UGTA mission, vision, and core values • Roles and responsibilities for key personnel • Communication with stakeholders • Guidance in key interface areas • Communication matrix

  6. Site characterization and validation - equipment design and techniques used in single borehole hydraulic testing, simulated drift experiment and crosshole testing

    International Nuclear Information System (INIS)

    Holmes, D.C.; Sehlstedt, M.

    1991-10-01

    This report describes the equipment and techniques used to investigate the variation of hydrogeological parameters within a fractured crystalline rock mass. The testing program was performed during stage 3 of the site characterization and validation programme at the Stripa mine in Sweden. This programme used a multidisciplinary approach, combining geophysical, geological and hydrogeological methods, to determine how groundwater moved through the rock mass. The hydrogeological work package involved three components. Firstly, novel single borehole techniques (focused packer testing) were used to determine the distribution of hydraulic conductivity and head along individual boreholes. Secondly, water was abstracted from boreholes which were drilled to simulate a tunnel (simulated drift experiment). Locations and magnitudes of flows were measured together with pressure responses at various points in the SCV rock mass. Thirdly, small scale crosshole tests, involving detailed interference testing, were used to determine the variability of hydrogeological parameters within previously identified, significant flow zones. (au)

  7. Strength and leak testing of plasma activated bonded interfaces

    DEFF Research Database (Denmark)

    Visser, M.M.; Weichel, Steen; Reus, Roger De

    2002-01-01

    on detection of changes in membrane deflections. The detection limit for leak was 8E-13 mbar l/s. For comparison, strength and leak tests were also performed with regular fusion bonded wafers annealed at 1100 degreesC. The PAB was found to withstand post-processing steps such as RCA cleaning, 24 h in de......-ionised water (DIW), 24 h in 2.5% HF, 24 h in acetone and 60 s in a resist developer. By analysing the thin silicon oxide present on the surfaces to be bonded with optical methods, the influence of pre-cleaning and activation process parameters was investigated....

  8. Equipment for functional testing of the ALADIN TXA pulsed laser head

    Science.gov (United States)

    Emanuele, Stucchi; Franco, Trespidi; Enzo, Nava

    2017-11-01

    It is described a measurement instrument, used as Optical Ground Support Equipment, capable of performing the characterization of a pulsed laser beam. The instrument was developed for the functional testing of the EQM and FMs of the ALADIN laser transmitter (TXA). The performed measurements are: beam shaping, M2 measurement, beam angular stability, energy and wavelength measurements, pulse duration, polarization, pulse shape and spectral characterization, optical frequency stability measurement. The measurement system can work in automatic mode performing several measurements and providing automatic report generation.

  9. Instantaneous response spectrum in seismic testing of nuclear power plant equipment

    International Nuclear Information System (INIS)

    Morrone, A.

    1977-01-01

    Seismic response spectra, as used in seismic analyses, give the maximum responses of single degree of freedom oscillators without consideration of the different time in the seismic time history at which each of the maximum responses occur. For response spectrum seismic analysis, the use of time-independent maximum responses is appropriate. The time dependece is considered in a statistical manner, for multi-degree of freedom systems, usually by combining the modal effects by the square root of the sum of the squares. For seismic testing of electrical equipment. IEEE Std. 344-1975 makes use of the response spectrum to define the input motion of the shake table. One of the basic requirements is that the test response spectrum (TRS) that is, the response spectrum produced by the shake table motion, should envelop the required response spectrum (RRS) calculated from the building analysis at the support point of the equipment being tested. This paper presents the concept of instantaneous response spectrum (IRS) as the response of single degree of freedom oscillators at a particular time. It demonstrates that a shake table random motion whose standard TRS envelops the RRS does not necessarily satisfy the enveloping requirement instantaneously. (Auth.)

  10. PAT portable appliance testing : in-service inspection and testing of electrical equipment

    CERN Document Server

    Scaddan, Brian

    2015-01-01

    The Electricity at Work Regulations 1989 requires any electrical system to be constructed, maintained and used in such a manner as to prevent danger. This means that inspection and testing of systems, including portable appliances, is needed in order to determine if maintenance is required. This book explains in clear language what needs to be done and includes expert advice on legislation as well as actual testing. The book contains an appendix providing the electrical fundamentals needed by non-specialists and also has sample questions (with answers) for the C&G 2377 exam. It is also an ideal revision guide for the non-specialist, such as maintenance staff and caretakers who carry out these tasks part-time, alongside their many other duties.

  11. Vibrodynamical tests of RP equipment with application of imitation area of WWER-1000 reactor

    International Nuclear Information System (INIS)

    Khajretdinov, V.U.; Tarkhanov, V.V.; Rodionova, I.N.

    2015-01-01

    Performance of preoperational tests and measurements with application of imitation area of the reactor is a distinctive characteristic of putting into operation of NPP Units with WWER-1000/1200. The imitation area consists of 163 full-scale FA models, where fuel matrixes made of nuclear-fissionable material, are replaced by leaden simulators. Vibrodynamic tests involve inspection of hydrodynamic disturbances in the primary circuit (dynamic impact on the inspected elements), characteristics of vibration response of the main equipment stress-deformed state of bearing structure, and also parameters of moving and geometry of the inspected objects (boundary conditions at process simulation). Preoperational tests and measurements on the simulated area of WWER-1000/1200 are obligatory and performed at every unit of NPP of this type [ru

  12. Miravalles Geothermal Project: Portable Well Flow Test Equipment and Procedures Manual

    Energy Technology Data Exchange (ETDEWEB)

    None

    1980-05-01

    The well flow test program has been designed to facilitate the gathering of information, with portable test equipment, from various wells with regard to their capability of flow, the quality of steam produced at various back pressures, the composition and quantity of noncondensable gases flashed from the wells and the composition and quantity of solids in the well's liquid streams (brine). The test program includes procedures for obtaining the following basic flow data pertinent to the plant power cycle design: (1) Effluent steam and brine flows, pressures and temperatures; (2) Noncondensable and dissolved gas contents in steam and brine; (3) H{sub s}S content in gases formed; and (4) Solids content and chemical analysis of steam and brine.

  13. Development of In situ Geological Investigation and Test Equipment in KURT

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Yong Kweon; Kim, Kyung Su; Park, Kyung Woo; Koh, Yong Kweon; Choi, Jong Won [KAERI, Daejeon (Korea, Republic of)

    2010-12-15

    For establishment of the advanced infrastructures of KURT, geological investigation and in situ test equipment were installed. The optical sensor technique could be applicable to monitoring system for the safe operation of various kinds of facilities having static and/or dynamic characteristics, such as chemical plant, pipeline, rail, huge building, long and slim structures, bridge, subway and marine vessel. etc. The micro-seismic monitoring system is able to predict the location and timing of fracturing of rock mass and rock fall around an underground openings as well as analysis on safety of various kinds of engineering structures such as nuclear facilities and other structures. The straddle packer system for hydro-testing in a deep borehole will lead to not only improve current technical level in the field of hydraulic testing but also provide important information to radioactive waste disposal technology development and site characterization project

  14. West Valley Demonstration Project vitrification process equipment Functional and Checkout Testing of Systems (FACTS)

    International Nuclear Information System (INIS)

    Carl, D.E.; Paul, J.; Foran, J.M.; Brooks, R.

    1990-01-01

    The Vitrification Facility (VF) at the West Valley Demonstration Project was designed to convert stored radioactive waste into a stable glass for disposal in a federal repository. The Functional and Checkout Testing of Systems (FACTS) program was conducted from 1984 to 1989. During this time new equipment and processes were developed, installed, and implemented. Thirty-seven FACTS tests were conducted, and approximately 150,000 kg of glass were made by using nonradioactive materials to simulate the radioactive waste. By contrast, the planned radioactive operation is expected to produce approximately 500,000 kg of glass. The FACTS program demonstrated the effectiveness of equipment and procedures in the vitrification system, and the ability of the VF to produce quality glass on schedule. FACTS testing also provided data to validate the WVNS waste glass qualification method and verify that the product glass would meet federal repository acceptance requirements. The system was built and performed to standards which would have enabled it to be used in radioactive service. As a result, much of the VF tested, such as the civil construction, feed mixing and holding vessels, and the off-gas scrubber, will be converted for radioactive operation. The melter was still in good condition after being at temperature for fifty-eight of the sixty months of FACTS. However, the melter exceeded its recommended design life and will be replaced with a similar melter. Components that were not designed for remote operation and maintenance will be replaced with remote-use items. The FACTS testing was accomplished with no significant worker injury or environmental releases. During the last FACTS run, the VF processes approximated the remote-handling system that will be used in radioactive operations. Following this run the VF was disassembled for conversion to a radioactive process. Functional and checkout testing of new components will be performed prior to radioactive operation

  15. Open-Source Assisted Laboratory Automation through Graphical User Interfaces and 3D Printers: Application to Equipment Hyphenation for Higher-Order Data Generation.

    Science.gov (United States)

    Siano, Gabriel G; Montemurro, Milagros; Alcaráz, Mirta R; Goicoechea, Héctor C

    2017-10-17

    Higher-order data generation implies some automation challenges, which are mainly related to the hidden programming languages and electronic details of the equipment. When techniques and/or equipment hyphenation are the key to obtaining higher-order data, the required simultaneous control of them demands funds for new hardware, software, and licenses, in addition to very skilled operators. In this work, we present Design of Inputs-Outputs with Sikuli (DIOS), a free and open-source code program that provides a general framework for the design of automated experimental procedures without prior knowledge of programming or electronics. Basically, instruments and devices are considered as nodes in a network, and every node is associated both with physical and virtual inputs and outputs. Virtual components, such as graphical user interfaces (GUIs) of equipment, are handled by means of image recognition tools provided by Sikuli scripting language, while handling of their physical counterparts is achieved using an adapted open-source three-dimensional (3D) printer. Two previously reported experiments of our research group, related to fluorescence matrices derived from kinetics and high-performance liquid chromatography, were adapted to be carried out in a more automated fashion. Satisfactory results, in terms of analytical performance, were obtained. Similarly, advantages derived from open-source tools assistance could be appreciated, mainly in terms of lesser intervention of operators and cost savings.

  16. Composite Service Life Prediction via Fiber Bundle Testing. Evaluation of Testing Equipment and Data Acquisition System

    Science.gov (United States)

    1986-12-01

    strength critical application for modern composites were filament-wound pressure vessels using glass fibers. What has highly motivated the effort of...stiffness to weight ratios the use of which is of cruisial importance in the aerospace industry. Another highly motivating aspect was the very high...single filament r’iber testing and can become more 29 3> C o - Pwo PwS ?w4 Pw3 Pw2 Pwl PSD Ps5 PS4 Ps3 Ps2 PS! homoiogous correspondence t ~ to Life ( Laqt

  17. Evaluation of sex-related changes in skin topography and structure using innovative skin testing equipment.

    Science.gov (United States)

    Dąbrowska, M; Mielcarek, A; Nowak, I

    2018-04-29

    Evaluation of skin condition on the basis of parametrization and objective measurements of the parameters has become obligatory. The aim of this study was to assess sex-related changes in skin topography and structure using the skin testing equipment. The study was carried out on the group of 40 volunteers (20 females and 20 males) of the mean age 24 ± 3 years. The skin parameters were measured using 3 devices: Visioscan ®  VC 98 (skin topography), Visioline ® VL 650 (skin macro relief) and Ultrascan UC22 (ultrasound imaging of the skin). All measurements were performed on the inner part of the left forearm. The skin parameters measured revealed significant differences in skin surface and structure between females and males. The skin of all women subjects was more homogenous in its structure with the presence of more abundant superficial skin lines and wrinkles in comparison to male skin. The higher number of skin furrows in the skin of women is in agreement with literature reports claiming that men's skin has lower number of wrinkles which are deeper and more pronounced. Ultrasound imaging of the skin indicated greater thickness and lower density of the dermis of men subjects compared to those of females. Non-invasive methods of skin testing using new and advanced equipment have provided a possibility of objective parametrization and evaluation of sex-related changes in skin topography and structure. © 2018 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Development of an above-knee prosthesis equipped with a microcomputer-controlled knee joint: first test results.

    Science.gov (United States)

    Aeyels, B; Peeraer, L; Vander Sloten, J; Van der Perre, G

    1992-05-01

    The shortcomings of conventional above-knee prostheses are due to their lack of adaptive control. Implementation of a microcomputer controlling the knee joint in a passive way has been suggested to enhance the patient's gait comfort, safety and cosmesis. This approach was used in the design of a new prosthetic system for the above-knee amputee, and tested on one patient. The knee joint of a conventional, modular prosthesis was replaced by a knee joint mechanism, equipped with a controllable brake on the knee joint axis. Sensors and a microcomputer were added, keeping the system self-contained. The modularity of the design permits the use of an alternative, external, PC-based control unit, emulating the self-contained one, and offering extended data monitoring and storage facilities. For both units an operating environment was written, including sensor/actuator interfacing and the implementation of a real-time interrupt, executing the control algorithm. A double finite state approach was used in the design of the control algorithm. On a higher level, the mode identification algorithm reveals the patient's intent. Within a specific mode (lower level), the relevant mode control algorithm looks for the current phase within the gait cycle. Within a particular phase, a specific simple control action with the brake replaces normal knee muscle activity. Tests were carried out with one prosthetic patient using a basic control algorithm for level walking, allowing controlled knee flexion during stance phase. The technical feasibility of such a concept is illustrated by the test results, even though only flexion during early stance phase was controlled during the trials.(ABSTRACT TRUNCATED AT 250 WORDS)

  19. The Mirror Fusion Test Facility cryogenic system: Performance, management approach, and present equipment status

    International Nuclear Information System (INIS)

    Slack, D.S.; Chronis, W.C.

    1987-01-01

    The cryogenic system for the Mirror Fusion Test Facility (MFTF) is a 14-kW, 4.35-K helium refrigeration system that proved to be highly successful and cost-effective. All operating objectives were met, while remaining within a few percent of initial cost and schedule plans. The management approach used in MFTF allowed decisions to be made quickly and effectively, and it helped keep costs down. Manpower levels, extent and type of industrial participation, key aspects of subcontractor specifications, and subcontractor interactions are reviewed, as well as highlights of the system tests, operation, and present equipment status. Organizations planning large, high-technology systems may benefit from this experience with the MFTF cryogenic system

  20. Quality control test solutions for diagnostic radiology, nuclear medicine and health physics with PTW equipment

    International Nuclear Information System (INIS)

    Froescher, Olga

    2007-01-01

    Complete test of publication follows. In 1922 PTW-Freiburg was founded to produce and market a revolutionary new electromechanical component for measuring very small electrical charges. Today PTW is the specialist and one of the global market leaders for manufacturing and supplying high-quality products in diagnostic radiology, nuclear medicine, radiation therapy and health physics. The quality control of X-ray images is influenced by a number of parameters. To maintain a consistent performance of X-ray installations, quality checks have to be conducted regularly. PTW offers a variety of diagnostic test tools for different X-ray devices, and therefore to reduce patient exposure and costs for X-ray departments. PTW's 'Code of Practice' defines in an easy and compact way how to perform quality control measurements on different diagnostic X-ray installations. The necessary equipment for measuring main parameters as well as acceptable limits are mentioned accordingly. The 'Code of Practice' bases on actual standards.

  1. Using cyber vulnerability testing techniques to expose undocumented security vulnerabilities in DCS and SCADA equipment

    International Nuclear Information System (INIS)

    Pollet, J.

    2006-01-01

    This session starts by providing an overview of typical DCS (Distributed Control Systems) and SCADA (Supervisory Control and Data Acquisition) architectures, and exposes cyber security vulnerabilities that vendors never admit, but are found through a comprehensive cyber testing process. A complete assessment process involves testing all of the layers and components of a SCADA or DCS environment, from the perimeter firewall all the way down to the end devices controlling the process, including what to look for when conducting a vulnerability assessment of real-time control systems. The following systems are discussed: 1. Perimeter (isolation from corporate IT or other non-critical networks) 2. Remote Access (third Party access into SCADA or DCS networks) 3. Network Architecture (switch, router, firewalls, access controls, network design) 4. Network Traffic Analysis (what is running on the network) 5. Host Operating Systems Hardening 6. Applications (how they communicate with other applications and end devices) 7. End Device Testing (PLCs, RTUs, DCS Controllers, Smart Transmitters) a. System Discovery b. Functional Discovery c. Attack Methodology i. DoS Tests (at what point does the device fail) ii. Malformed Packet Tests (packets that can cause equipment failure) iii. Session Hijacking (do anything that the operator can do) iv. Packet Injection (code and inject your own SCADA commands) v. Protocol Exploitation (Protocol Reverse Engineering / Fuzzing) This paper will provide information compiled from over five years of conducting cyber security testing on control systems hardware, software, and systems. (authors)

  2. Using cyber vulnerability testing techniques to expose undocumented security vulnerabilities in DCS and SCADA equipment

    Energy Technology Data Exchange (ETDEWEB)

    Pollet, J. [PlantData Technologies, Inc., 1201 Louisiana Street, Houston, TX 77002 (United States)

    2006-07-01

    This session starts by providing an overview of typical DCS (Distributed Control Systems) and SCADA (Supervisory Control and Data Acquisition) architectures, and exposes cyber security vulnerabilities that vendors never admit, but are found through a comprehensive cyber testing process. A complete assessment process involves testing all of the layers and components of a SCADA or DCS environment, from the perimeter firewall all the way down to the end devices controlling the process, including what to look for when conducting a vulnerability assessment of real-time control systems. The following systems are discussed: 1. Perimeter (isolation from corporate IT or other non-critical networks) 2. Remote Access (third Party access into SCADA or DCS networks) 3. Network Architecture (switch, router, firewalls, access controls, network design) 4. Network Traffic Analysis (what is running on the network) 5. Host Operating Systems Hardening 6. Applications (how they communicate with other applications and end devices) 7. End Device Testing (PLCs, RTUs, DCS Controllers, Smart Transmitters) a. System Discovery b. Functional Discovery c. Attack Methodology i. DoS Tests (at what point does the device fail) ii. Malformed Packet Tests (packets that can cause equipment failure) iii. Session Hijacking (do anything that the operator can do) iv. Packet Injection (code and inject your own SCADA commands) v. Protocol Exploitation (Protocol Reverse Engineering / Fuzzing) This paper will provide information compiled from over five years of conducting cyber security testing on control systems hardware, software, and systems. (authors)

  3. Engineering Work Plan for the Development of Phased Startup Initiative (PSI) Phases 3 and 4 Test Equipment

    International Nuclear Information System (INIS)

    PITNER, A.L.

    2000-01-01

    A number of tools and equipment pieces are required to facilitate planned test operations during Phases 3 and 4 of the Phased Startup Initiative (PSI). These items will be used in assessing residual canister sludge quantities on cleaned fuel assemblies, sorting coarse and fine scrap fuel pieces, assessing the size distribution of scrap pieces, loading scrap into a canister, and measuring the depth of the accumulated scrap in a canister. This work plan supercedes those previously issued for development of several of these test items. These items will be considered prototype equipment until testing has confirmed their suitability for use in K West Basin. The process described in AP-EN-6-032 will be used to qualify the equipment for facility use. These items are considered non-OCRWM for PSI Phase 3 applications. The safety classification of this equipment is General Service, with Quality Level 0 (for PSI Phase 3). Quality Control inspections shall be performed to verify basic dimensions and overall configurations of fabricated components, and any special quality control verifications specified in this work plan (Section 3.1.5). These inspections shall serve to approve the test equipment for use in K West Basin (Acceptance Tag). This equipment is for information gathering only during PSI Phases 3 and 4 activities, and will be discarded at the completion of PSI. For equipment needed to support actual production throughput, development/fabrication/testing activities would be more rigorously controlled

  4. Follow-up of the evolution of the characteristics and performance of the equipments tested during a KALI campaign

    International Nuclear Information System (INIS)

    Rouaud, J.

    1985-01-01

    One of the four parts of the K1 qualification of the 1E equipments concerns the design basis accidents. The KALI loops allows to create the thermodynamic conditions of these accidents. This paper presents the PROCESS II which concerns the installation of the equipment in conditions representative of those met in nuclear power plants, the control assurance before, during and after the thermodynamic test. A list of qualification tests carried out on the KALI loop is finally given [fr

  5. Interface Testing for RTOS System Tasks based on the Run-Time Monitoring

    International Nuclear Information System (INIS)

    Sung, Ahyoung; Choi, Byoungju

    2006-01-01

    Safety critical embedded system requires high dependability of not only hardware but also software. It is intricate to modify embedded software once embedded. Therefore, it is necessary to have rigorous regulations to assure the quality of safety critical embedded software. IEEE V and V (Verification and Validation) process is recommended for software dependability, but a more quantitative evaluation method like software testing is necessary. In case of safety critical embedded software, it is essential to have a test that reflects unique features of the target hardware and its operating system. The safety grade PLC (Programmable Logic Controller) is a safety critical embedded system where hardware and software are tightly coupled. The PLC has HdS (Hardware dependent Software) and it is tightly coupled with RTOS (Real Time Operating System). Especially, system tasks that are tightly coupled with target hardware and RTOS kernel have large influence on the dependability of the entire PLC. Therefore, interface testing for system tasks that reflects the features of target hardware and RTOS kernel becomes the core of the PLC integration test. Here, we define interfaces as overlapped parts between two different layers on the system architecture. In this paper, we identify interfaces for system tasks and apply the identified interfaces to the safety grade PLC. Finally, we show the test results through the empirical study

  6. Interface Testing for RTOS System Tasks based on the Run-Time Monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Ahyoung; Choi, Byoungju [Ewha University, Seoul (Korea, Republic of)

    2006-07-01

    Safety critical embedded system requires high dependability of not only hardware but also software. It is intricate to modify embedded software once embedded. Therefore, it is necessary to have rigorous regulations to assure the quality of safety critical embedded software. IEEE V and V (Verification and Validation) process is recommended for software dependability, but a more quantitative evaluation method like software testing is necessary. In case of safety critical embedded software, it is essential to have a test that reflects unique features of the target hardware and its operating system. The safety grade PLC (Programmable Logic Controller) is a safety critical embedded system where hardware and software are tightly coupled. The PLC has HdS (Hardware dependent Software) and it is tightly coupled with RTOS (Real Time Operating System). Especially, system tasks that are tightly coupled with target hardware and RTOS kernel have large influence on the dependability of the entire PLC. Therefore, interface testing for system tasks that reflects the features of target hardware and RTOS kernel becomes the core of the PLC integration test. Here, we define interfaces as overlapped parts between two different layers on the system architecture. In this paper, we identify interfaces for system tasks and apply the identified interfaces to the safety grade PLC. Finally, we show the test results through the empirical study.

  7. Test of large-scale specimens and models as applied to NPP equipment materials

    International Nuclear Information System (INIS)

    Timofeev, B.T.; Karzov, G.P.

    1993-01-01

    The paper presents the test results on low-cycle fatigue, crack growth rate and fracture toughness of large-scale specimens and structures, manufactured from steel, widely applied in power engineering industry and used for the production of NPP equipment with VVER-440 and VVER-1000 reactors. The obtained results are compared with available test results of standard specimens and calculation relations, accepted in open-quotes Calculation Norms on Strength.close quotes At the fatigue crack initiation stage the experiments were performed on large-scale specimens of various geometry and configuration, which permitted to define 15X2MFA steel fracture initiation resistance by elastic-plastic deformation of large material volume by homogeneous and inhomogeneous state. Besides the above mentioned specimen tests in the regime of low-cycle loading, the test of models with nozzles were performed and a good correlation of the results on fatigue crack initiation criterium was obtained both with calculated data and standard low-cycle fatigue tests. It was noted that on the Paris part of the fatigue fracture diagram a specimen thickness increase does not influence fatigue crack growth resistance by tests in air both at 20 and 350 degrees C. The estimation of the comparability of the results, obtained on specimens and models was also carried out for this stage of fracture. At the stage of unstable crack growth by static loading the experiments were conducted on specimens of various thickness for 15X2MFA and 15X2NMFA steels and their welded joints, produced by submerged arc welding, in as-produced state (the beginning of service) and after embrittling heat treatment, simulating neutron fluence attack (the end of service). The obtained results give evidence of the possibility of the reliable prediction of structure elements brittle fracture using fracture toughness test results on relatively small standard specimens. 35 refs., 23 figs

  8. ENGINEERING DESIGN OPTIMIZATION OF HEEL TESTING EQUIPMENT IN THE EXPERIMENTAL VALIDATION OF SAFE WALKING

    Directory of Open Access Journals (Sweden)

    Cristiano Fragassa

    2017-06-01

    Full Text Available Experimental test methods for the evaluation of the resistance of heels of ladies' shoes in the case of impact loads are fully defined by International Organization for Standardization (ISO procedures that indicate all the conditions of experiment. A first Standard (ISO 19553 specifies the test method for determining the strength of the heels in the case of single impact. The result offers a valuation of the liability to fail under the sporadic heavy blows. A second Standard (ISO 19556 details a method for testing the capability of heels of women' shoes to survive to the repetition of small impacts provoked by normal walking. These Standards strictly define the features for two different testing devices (with specific materials, geometries, weights, etc. and all the experimental procedures to be followed during tests. On the contrary, this paper describes the technical solutions adopted to design one single experimental device able to perform impact testing of heels in both conditions. Joining the accuracy of mechanic movements with the speed of an electronic control system, a new and flexible equipment for the complete characterization of heels respect to (single or fatigue impacts was developed. Moreover a new level of performances in experimental validation of heel resistance was introduced by the versatility of the user-defined software control programs, able to encode every complex time-depending cycle of impact loads. Dynamic simulations permitted to investigate the impacts on heel in different conditions of testing, optimizing the machine design. The complexity of real stresses on shoes during an ordinary walk and in other common situations (as going up and downstairs was considered for a proper dimensioning.

  9. The role of a certified calibration laboratory in a station's measuring and test equipment calibration, repair, and documentation program

    International Nuclear Information System (INIS)

    Ebenstreit, K.; MacIntosh, N.

    1995-01-01

    This paper outlines the role of a Certified Calibration Laboratory in- ensuring that the requirements of Measuring and Test Equipment calibration, identification, and traceability are met and documented. The Nuclear environment is one which is subject to influences from numerous 'quality agents'. One of the fields which comes under the scrutiny of the quality agents is that of equipment calibration and repair (both field components and M and TE). There is a responsibility to produce a superior product for the Ontario Consumer. The maintenance and calibration of Station Systems and their components have a direct impact on this output. The Measuring and Test Equipment element in each of these needs can be addressed by having a defined group of Maintenance Staff to execute a Measuring and Test Equipment Program which meets specific parameters. (author)

  10. Determination of the bonding strength in solid oxide fuel cells' interfaces by Schwickerath crack initiation test

    DEFF Research Database (Denmark)

    Boccaccini, D. N.; Sevecek, O.; Frandsen, Henrik Lund

    2017-01-01

    An adaptation of the Schwickerath crack initiation test (ISO 9693) was used to determine the bonding strength between an anode support and three different cathodes with a solid oxide fuel cell interconnect. Interfacial elemental characterization of the interfaces was carried out by SEM/EDS analys...

  11. TESTAR : Tool Support for Test Automation at the User Interface Level

    NARCIS (Netherlands)

    Vos, Tanja E.J.; Kruse, Peter M.; Condori Fernandez, Nelly; Bauersfeld, Sebastian; Wegener, Joachim

    2015-01-01

    Testing applications with a graphical user interface (GUI) is an important, though challenging and time consuming task. The state of the art in the industry are still capture and replay tools, which may simplify the recording and execution of input sequences, but do not support the tester in finding

  12. Non-destructive testing of a NPP's metallic equipment during operation

    International Nuclear Information System (INIS)

    Brodskij, B.R.; Monina, Eh.F.

    1977-01-01

    Some nondestructive testing methods and facilities currently used in the USSR and overseas to remotely control the quality of a NPPs metallic equipment during operation are reviewed. The ultrasonic and γ scanning devices designed to verify the integrity of nuclear reactor pressure vessels and piping weldments are considered. The acoustic emission techniques, ultrasonic holography and routine ultrasonic fault detection are acknowledged the most promising and safe when applied to reactor vessels. On the other hand, the radiographic methods are pointed out not to quarantee the identification of a flaw. There is also a description of a container designed to maintain and repair a nuclear reactor in the highly radioactive environment. The increased interest of foreign firms towards acoustic emission techniques is stressed

  13. Assessing the Impact of Clothing and Individual Equipment (CIE) on Soldier Physical, Biomechanical, and Cognitive Performance Part 1: Test Methodology

    Science.gov (United States)

    2018-02-01

    29 during Soldier Equipment Configuration Impact on Performance: Establishing a Test Methodology for the...during ACSM’S resource manual for exercise testing and prescription Human Movement Science, 31(2), Proceedings of the 2016 American Biomechanics...Performance of Medium Rucksack Prototypes An investigation: Comparison of live-fire and weapon simulator test methodologies and the of three extremity armor

  14. A estrutura da representação social da morte na interface com as religiosidades em equipes multiprofissionais de saúde The structure of social representation of death in the interface with the religiosities of healthcare professionals groups

    Directory of Open Access Journals (Sweden)

    Alexsandro Medeiros do Nascimento

    2007-01-01

    Full Text Available O estudo objetivou acessar a estrutura da representação social da morte em equipes multiprofissionais de saúde na interface com a religiosidade, no que esta interfere nas significações atribuídas à morte por esta população em específico. Utilizou-se um instrumento com questões abertas e fechadas sobre a morte e o morrer, bem como sobre a vivência religiosa singular dos participantes. Protocolos escritos foram capturados em uma amostra de 80 profissionais (49 médicos, 13 psicólogas, 18 enfermeiras pertencentes a 10 equipes multiprofissionais de saúde. Estes foram analisados através de Análise de Conteúdo e de Análise de Estrutura de Similaridade (SSA e interpretados pela Teoria das Representações Sociais. Os dados revelaram uma interferência expressiva das crenças religiosas na estruturação da representação da Morte.The study aims to investigate the structure of social representation of death in a Healthcare professional group establishing an interface with religiosity and how the latter interferes in the meaning attributed to death by this specific population. Open and closed questions on death or the act of dying, and on the singular religious experience of the participants were applied. Written protocols were collected from a sample of 80 professionals (49 physicians, 13 psychologists, and 18 nurses, which were analyzed according to content analysis and non-metric multidimensional analysis, SSA (Similarity Structure Analysis, and interpreted according to the theory of Social Representations, revealing a significant interference of religious believes in the structure of death representation.

  15. Testing of Environmental Satellite Bus-Instrument Interfaces Using Engineering Models

    Science.gov (United States)

    Gagnier, Donald; Hayner, Rick; Nosek, Thomas; Roza, Michael; Hendershot, James E.; Razzaghi, Andrea I.

    2004-01-01

    This paper discusses the formulation and execution of a laboratory test of the electrical interfaces between multiple atmospheric scientific instruments and the spacecraft bus that carries them. The testing, performed in 2002, used engineering models of the instruments and the Aura spacecraft bus electronics. Aura is one of NASA s Earth Observatory System missions. The test was designed to evaluate the complex interfaces in the command and data handling subsystems prior to integration of the complete flight instruments on the spacecraft. A problem discovered during the flight integration phase of the observatory can cause significant cost and schedule impacts. The tests successfully revealed problems and led to their resolution before the full-up integration phase, saving significant cost and schedule. This approach could be beneficial for future environmental satellite programs involving the integration of multiple, complex scientific instruments onto a spacecraft bus.

  16. Equipping a glovebox for waste form testing and characterization of plutonium bearing materials

    International Nuclear Information System (INIS)

    Noy, M.; Johnson, S.G.; Moschetti, T.L.

    1997-01-01

    The recent decision by the Department of Energy to pursue a hybrid option for the disposition of weapons plutonium has created the need for additional facilities that can examine and characterize waste forms that contain Pu. This hybrid option consists of the placement of plutonium into stable waste forms and also into mixed oxide fuel for commercial reactors. Glass and glass-ceramic waste forms have a long history of being effective hosts for containing radionuclides, including plutonium. The types of tests necessary to characterize the performance of candidate waste forms include: static leaching experiments on both monolithic and crushed waste forms, microscopic examination, and density determination. Frequently, the respective candidate waste forms must first be produced using elevated temperatures and/or high pressures. The desired operations in the glovebox include, but are not limited to the following: (1) production of vitrified/sintered samples, (2) sampling of glass from crucibles or other vessels, (3) preparing samples for microscopic inspection and monolithic and crushed static leach tests, and (4) performing and analyzing leach tests in situ. This paper will describe the essential equipment and modifications that are necessary to successfully accomplish the goal of outfitting a glovebox for these functions

  17. The Tanzania experience: clinical laboratory testing harmonization and equipment standardization at different levels of a tiered health laboratory system.

    Science.gov (United States)

    Massambu, Charles; Mwangi, Christina

    2009-06-01

    The rapid scale-up of the care and treatment programs in Tanzania during the preceding 4 years has greatly increased the demand for quality laboratory services for diagnosis of HIV and monitoring patients during antiretroviral therapy. Laboratory services were not in a position to cope with this demand owing to poor infrastructure, lack of human resources, erratic and/or lack of reagent supply and commodities, and slow manual technologies. With the limited human resources in the laboratory and the need for scaling up the care and treatment program, it became necessary to install automated equipment and train personnel for the increased volume of testing and new tests across all laboratory levels. With the numerous partners procuring equipment, the possibility of a multitude of equipment platforms with attendant challenges for procurement of reagents, maintenance of equipment, and quality assurance arose. Tanzania, therefore, had to harmonize laboratory tests and standardize laboratory equipment at different levels of the laboratory network. The process of harmonization of tests and standardization of equipment included assessment of laboratories, review of guidelines, development of a national laboratory operational plan, and stakeholder advocacy. This document outlines this process.

  18. Brain-muscle-computer interface: mobile-phone prototype development and testing.

    Science.gov (United States)

    Vernon, Scott; Joshi, Sanjay S

    2011-07-01

    We report prototype development and testing of a new mobile-phone-based brain-muscle-computer interface for severely paralyzed persons, based on previous results from our group showing that humans may actively create specified power levels in two separate frequency bands of a single surface electromyography (sEMG) signal. EMG activity on the surface of a single face muscle site (auricularis superior) is recorded with a standard electrode. This analog electrical signal is imported into an Android-based mobile phone and digitized via an internal A/D converter. The digital signal is split, and then simultaneously filtered with two band-pass filters to extract total power within two separate frequency bands. The user-modulated power in each frequency band serves as two separate control channels for machine control. After signal processing, the Android phone sends commands to external devices via a Bluetooth interface. Users are trained to use the device via visually based operant conditioning, with simple cursor-to-target activities on the phone screen. The mobile-phone prototype interface is formally evaluated on a single advanced Spinal Muscle Atrophy subject, who has successfully used the interface in his home in evaluation trials and for remote control of a television. Development of this new device will not only guide future interface design for community use, but will also serve as an information technology bridge for in situ data collection to quantify human sEMG manipulation abilities for a relevant population.

  19. Is there a role for a test controller in the development of new ATC equipment?

    Science.gov (United States)

    Westrum, Ron

    1994-01-01

    Earl Wiener points out that human factors problems fixed during the R & D stage are paid for once. When they are not fixed during R & D, they are then paid for every day. How users are involved in the R & D process to assist in developing equipment is a critical issue. Effective involvement can produce real improvements. Ineffective involvement can produce inefficient kludges or systems that are actually dangerous. The underlying problem is the management of information and ideas. To develop a really generative system a great deal would have to change in the way that the FAA innovates. Use of test controllers would solve only some of the problems. For instance, we have cockpit resource management now for pilots; we may have it soon for controllers. But the management of ideas in the innovation process also needs intellectual resource management. Simply involving users is not enough. Brought in at the wrong point in the development process, users can block or compromise innovation. User involvement must be carefully considered. A test controller may be one solution to this problem. It might be necessary to have several kinds of test controllers (en route versus TRACON, for instance). No doubt further problems would surface in getting test controllers into operation. I would recommend that the FAA engage in a series of case studies of controller involvement in the innovation process. A systematic comparison of effective and ineffective cases would do much to clarify what we ought to do in the future. Unfortunately, I have been unable to find any cases where test controllers have been used. Perhaps we need to create some, to see how they work.

  20. An engineer's guide to automated testing of high-speed interfaces

    CERN Document Server

    Moreira, Jose

    2010-01-01

    Providing a complete introduction to the state-of-the-art in high-speed digital testing with automated test equipment (ATE), this practical resource is the first book focus exclusively on this increasingly important topic. Featuring clear examples, this one-stop reference covers all critical aspects of the subject, from high-speed digital basics, ATE instrumentation for digital applications, and test and measurements, to production testing, support instrumentation and text fixture design. This in-depth volume also discusses at advanced ATE topics, such as multiplexing of ATE pin channels and t

  1. Compliance testing of medical diagnostic x-ray equipment: three years experience of a public hospital in western Australia

    International Nuclear Information System (INIS)

    Tuchyna, T.; Jacob, C.S.

    2000-01-01

    Full text: A formal compliance testing program which began on 1 January 1997 called for all medical and diagnostic x-ray equipment to be tested according to protocols established by the Western Australian Radiological Council. This work describes the impact of the legislation three years post implementation on a major teaching Hospital with 45 x-ray tubes located throughout 37 rooms. Testing is performed prior to scheduled service by licensed compliance testers according to test methods specified in the Western Australian Compliance Testing Workbook, 1997. A dedicated non-invasive x-ray beam analyser is instrumental in accurately determining radiation output parameters of the generator and x-ray tube. Assessment of compliance is determined by a Qualified Expert. Repair and re-testing of non-compliant items is coordinated with service personnel. Notices of non-compliance were received for approximately 60% of the equipment in the Hospital following the equipment' first annual test. Reasons and seriousness of failure varied according to equipment category, test category, equipment use and age. The majority of non-compliance issues were resolved within 90 days. At the end of the third year of testing, approximately 75% of the x-ray units tested met the compliance criteria. The main reasons for non-compliance were found to be design limitations associated with old technology and the current radiation legislation that makes it difficult for older equipment to meet the stringent criteria. The number and categories of failure did not significantly decrease in the second or third years of testing. Exemptions from compliance criteria have been sought for two units on the basis of age and design. Units unable to meet the criteria following several repair attempts or where the cost of repair was deemed not justified, were decommissioned. Formal testing of medical x-ray equipment has demonstrated various non-compliance issues that did not significantly improve during the

  2. Design, construction and testing of replacement nuclear coolant pump stators to meet today's equipment reliability expectations

    International Nuclear Information System (INIS)

    Fostier, L.; Howell, D.

    2005-01-01

    The reliability expectations of equipment and components in today's nuclear power plant are much greater than three or more decades ago when nuclear plants were first constructed due to economic impact of a failure. Very few components in a pressurized water reactor plant can have as much impact of the plants capacity factor as a catastrophic failure of a reactor coolant pump winding. This paper describes the maintenance approach taken by one North American utility in attempt to preclude such failures. The paper will discuss the challenges of the reactor coolant pump application and the enhancements made in the winding design and construction by the supplier to address failure mechanisms so as to better meet present reliability expectations in accordance with dedicated specifications. The paper will also present the in-process and final testing requirements and limits imposed in an attempt to ensure quality of the machine windings, along with selected test results from the stators that have been designed and constructed to these specifications to date. (author)

  3. Nuclear electronic equipment for control and monitoring panel. Specifications and methods for testing radiation detectors

    International Nuclear Information System (INIS)

    Roguin, Andre.

    1976-02-01

    This document will be of interest to users and makers of neutron and gamma radiations detectors in the field of nuclear reactor control and protection. Information is given which will enable users to optimize their choice and methods of using equipment, and makers to optimize their methods of fabrication. It should also serve as a model from which official specifications, technical instructions and test methods for these detectors, could be established. A detailed description is given of the appropriate parameters, terminology and notations. General specifications, operating conditions and test methods are indicated. The following detectors are studied: in-core detectors: fission ionization chambers, self powered neutron detectors (S.P.N.D.); out-core detectors: boron ionization chambers (for monitoring), boron trifluoride proportional counter tubes, boron lined proportional counter tubes, helium-3 proportional counter tubes. The devices described in the document are intended for industrial radiation monitoring applications and not for calibration standards (dosimetry) or for health physics measurement purposes. They are characterized by their fidelity, fast response, reliability and long lifetimes [fr

  4. 46 CFR 199.45 - Tests and inspections of lifesaving equipment and arrangements.

    Science.gov (United States)

    2010-10-01

    ... such as lifebuoys, lifejackets, immersion suits, work vests, lifefloats, buoyant apparatus, and..., immersion suits, work vests, lifefloats, buoyant apparatus, and associated equipment; (4) The proper...

  5. Nuclear Technology. Course 32: Nondestructive Examination (NDE) Techniques II. Module 32-4, Operation of Magnetic Particle Test Equipment.

    Science.gov (United States)

    Groseclose, Richard

    This fourth in a series of six modules for a course titled Nondestructive Examination (NDE) Techniques II describes the specific technique variables and options which are available to the test technician, provides instructions for selecting and operating the appropriate test equipment, describes physical criteria for detectable discontinuities,…

  6. Methodical installations for fast resource testing of reliability of electrotechnical components intended for NPP equipment; Metodicheskie ustanovki dlya uskorennykh roesursnykh ispytanij na nadezhnost ` ehlektrotekhnicheskikh komplektuyushchikh, vkhodyashchikh v sostav oborudovaniya AEhS i yadernykh ustanovok

    Energy Technology Data Exchange (ETDEWEB)

    Shestakov, V S

    1994-12-31

    Installations for testing the electrotechnical equipment, microswitches for mechanical bend tests of cables as well as for high voltage tests of electrotechnical equipment are developed and described.

  7. Acceptance test procedure for the master equipment list (MEL)database system -- phase I

    International Nuclear Information System (INIS)

    Jech, J.B.

    1997-01-01

    The Waste Remediation System/.../Facilities Configuration Management Integration group has requested development of a system to help resolve many of the difficulties associated with management of master equipment list information. This project has been identified as Master Equipment List (MEL) database system. Further definition is contained in the system requirements specification (SRS), reference 7

  8. Radiation Tolerance Qualification Tests of the Final Source Interface Unit for the ALICE Experiment

    CERN Document Server

    Dénes, E; Futó, E; Kerék, A; Kiss, T; Molnár, J; Novák, D; Soós, C; Tölyhi, T; Van de Vyvre, P

    2007-01-01

    The ALICE Detector Data Link (DDL) is a high-speed optical link designed to interface the readout electronics of ALICE sub-detectors to the DAQ computers. The Source Interface Unit (SIU) of the DDL will operate in radiation environment. Previous tests showed that a configuration loss of SRAM-based FPGA devices may happen and the frequency of undetected data errors in the FPGA user memory area is also not acceptable. Therefore, we redesigned the SIU card using another FPGA based on flash technology. In order to detect bit errors in the user memory we added parity check logic to the design. The new SIU has been extensively tested using neutron and proton irradiation to verify its radiation tolerance. In this paper we summarize the design changes, introduce the final design, and the results of the radiation tolerance measurements on the final card.

  9. Study on cord/rubber interface at elevated temperatures by H-pull test method

    Science.gov (United States)

    Jamshidi, M.; Afshar, F.; Mohammadi, N.; Pourmahdian, S.

    2005-08-01

    Cords are used as reinforcing materials in rubber compounds. To increase cord/rubber interfacial adhesion, they are coated by an adhesive (usually based on resorcinol-formaldehyde-latex). These composites are used in many sectors such as tire and belt industries. Cord/rubber adhesion strength is an important aspect to determine the durability of system. Due to temperature increase during running tires, the adhesion energy becomes different from initial one. To study cord/rubber interface at elevated temperatures, H-adhesion test method was used. H-pull test is a simple method for adhesion evaluation at ambient temperature, so it is usually used for material quality control. In this research, cord/rubber systems were vulcanized at different temperatures and H-adhesion of samples were evaluated at elevated temperatures. Also cord/rubber interface was studied by ATR analyze to determine interfacial interactions kind.

  10. A user interface for the Kansas Geological Survey slug test model.

    Science.gov (United States)

    Esling, Steven P; Keller, John E

    2009-01-01

    The Kansas Geological Survey (KGS) developed a semianalytical solution for slug tests that incorporates the effects of partial penetration, anisotropy, and the presence of variable conductivity well skins. The solution can simulate either confined or unconfined conditions. The original model, written in FORTRAN, has a text-based interface with rigid input requirements and limited output options. We re-created the main routine for the KGS model as a Visual Basic macro that runs in most versions of Microsoft Excel and built a simple-to-use Excel spreadsheet interface that automatically displays the graphical results of the test. A comparison of the output from the original FORTRAN code to that of the new Excel spreadsheet version for three cases produced identical results.

  11. On-Line Radiation Test Facility for Industrial Equipment needed for the Large Hadron Collider at CERN

    CERN Document Server

    Rausch, R

    1999-01-01

    The future Large Hadron Collider to be built at CERN will use superconducting magnets cooled down to 1.2 K. To preserve the superconductivity, the energy deposition dose levels in equipment located outside the cryostat, in the LHC tunnel, are calculated to be of the order of 1 to 10 Gy per year. At such dose levels, no major radiation-damage problems are to be expected, and the possibility of installing Commercial Of The Shelf (COTS) electronic equipment in the LHC tunnel along the accelerator is considered. To this purpose, industrial electronic equipment and circuits have to be qualified and tested against radiation to insure their long term stability and reliability. An on-line radiation test facility has been setup at the CERN Super Proton Synchrotron (SPS) and a program of on-line tests for electronic equipment is ongoing. Equipment tested includes Industrial Programmable Logic Controllers (PLCs) from several manufacturers, standard VME modules, Fieldbuses like Profibus, WorldFIP and CAN, various electro...

  12. Determination of Cd, Cr, Hg and Pb in plastics from waste electrical and electronic equipment by inductively coupled plasma mass spectrometry with collision-reaction interface technology.

    Science.gov (United States)

    Santos, Mirian C; Nóbrega, Joaquim A; Cadore, Solange

    2011-06-15

    A procedure based on the use of a quadrupole inductively coupled plasma-mass spectrometer equipped with a collision-reaction interface (CRI) for control of spectral overlap interferences was developed for simultaneous determination of Cd, Cr, Hg, and Pb in plastics from waste electrical and electronic equipment (WEEE). The injection of H(2) and He (80 and 60 mL min(-1), respectively) into the sampled plasma, colliding and reacting with potentially interfering polyatomic ions, allows interference-free determination of chromium via its isotopes (52)Cr and (53)Cr that are freed from overlap due to the occurrence of (40)Ar(12)C(+), (40)Ar(12)C(1)H(+), (36)S(16)O(+) or (1)H(36)S(16)O(+). Cadmium, Hg and Pb were directly determined via their isotopes (110)Cd, (111)Cd, (112)Cd, (199)Hg, (200)Hg, (201)Hg, (202)Hg, (206)Pb, (207)Pb, and (208)Pb, without using CRI. The CRI can be quickly activated or deactivated before each analyte measurement. Limits of detection for (52)Cr were 0.04 or 0.14 μg L(-1) with He or H(2) injected in CRI. Cadmium and Pb have LODs between 0.02 and 0.08 μg L(-1) and Hg had 0.93-0.98 μg L(-1), without using CRI. Analyte concentrations for samples varied from 16 to 43, 1 to 11, 4 to 12, and 5 to 13 mg kg(-1) for Cr, Cd, Hg and Pb, respectively. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. Equipment for fully homologous bulb turbine model testing in Laval University

    International Nuclear Information System (INIS)

    Fraser R; Vallée D; Jean Y; Deschênes C

    2014-01-01

    Within the context of liberalisation of the energy market, hydroelectricity remains a first class source of clean and renewable energy. Combining the growing demand of energy, its increasing value and the appreciation associated to the sustainable development, low head sites formerly considered as non-profitable are now exploitable. Bulb turbines likely to equip such sites are traditionally developed on model using right angle transmission leading to piers enlargement for power take off shaft passage, thus restricting possibilities to have fully homologous hydraulic passages. Aiming to sustain good quality development on fully homologous scale model of bulb turbines, the Hydraulic Machines Laboratory (LAMH) of Laval University has developed a brake with an enhanced power to weight ratio. This powerful brake is small enough to be located in the bulb shell while dissipating power without mandatory test head reduction. This paper first presents the basic technology of this brake and its application. Then both its main performance capabilities and dimensional characteristics will be detailed. The instrumentation used to perform accurate measurements will be finally presented

  14. Nondestructive testing of delaminated interfaces between two materials using electromagnetic interrogation

    Science.gov (United States)

    Cakoni, Fioralba; de Teresa, Irene; Monk, Peter

    2018-06-01

    We consider the problem of detecting whether two materials that should be in contact have separated or delaminated using electromagnetic radiation. The interface damage is modeled as a thin opening between two materials of different electromagnetic properties. To derive a reconstruction algorithm that focuses on testing for the delamination at the interface between the two materials, we use the approximate asymptotic model for the forward problem derived in de Teresa (2017 PhD Thesis University of Delaware). In this model, the differential equations in the small opening are replaced by approximate transmission conditions for the electromagnetic fields across the interface. We also assume that the undamaged or background state is known and it is desired to find where the delamination has opened. We adapt the linear sampling method to this configuration in order to locate the damaged part of the interface from a knowledge of the scattered field and the undamaged configuration, but without needing to know the electromagnetic properties of the opening. Numerical examples are presented to validate our algorithm.

  15. Development of a handmade device for collimation and central ray alignment tests in medical X-ray equipment

    International Nuclear Information System (INIS)

    Cruz, B.L. da; Brito, E.B.; Gomes, A.S.

    2017-01-01

    Ordinance 453/98 of the Ministry of Health establishes that medical X-ray equipment should be monitored by tests that prove its efficiency. This practice is called quality control (QC), and two important tests jointly evaluate the operation of the collimation and alignment systems of the central axis of the X-ray beam. The low supply and the high cost generate allegations of difficulties in the periodic realization of the tests. The aim of this work is to design, make and evaluate the performance of a handmade device for the mentioned tests, using low cost materials. Once built, the device had its performance evaluated and compared with the traditionally marketed device. The handmade device proved to be fit in its functions. It is possible to make a device that tests X-ray medical equipment, using the radiology technologist himself as the test runner. Radiation protection is promoted and legislation with no real financial burden

  16. A method to evaluate the perceived ease of use of human-machine interface in agricultural tractors equipped with Continuously Variable Transmission (CVT)

    International Nuclear Information System (INIS)

    Caffaro, F.; Bisaglia, C.; Cutini, M.; Cremasco, M.M.; Cavallo, E.

    2017-01-01

    At the end of the 20th century the adoption of the Continuously Variable Transmission (CVT) was one of the disruptive technological advances in agricultural tractors. Several changes in the Human Machine Interface (HMI) of the tractor cab have been introduced to accommodate this technology. HMIs are known to raise issues about their ease of use; however, this topic has been under-investigated in the agricultural sector. The present study introduces a method to investigate the perceived ease of use of the HMI of agricultural tractors equipped with technological innovations. The HMI required to manage a CVT tractor was evaluated by sixteen tractor drivers (8 novices and 8 experts). During the first contact with the machine and after having performed two targeted tasks with the tractor, participants filled in a questionnaire about the ease of use of the controls and of the touch-screen display, and evaluated the general perception of ease of use, safety, quality and solidity of the machine. The trial pointed out some significant differences between novices and experts, thus confirming the validity of the proposed method. In particular, novice users showed some difficulties when interacting for the first time with the HMI of the CVT tractor working station, whereas experts did not report similar difficulties. Thus, expertise seems to play a role in determining the quality of the interaction with the HMI. Training interventions should be designed to help novices in increasing their expertise effectively, avoiding effort and errors and improving user’s comfort and system performance.

  17. A method to evaluate the perceived ease of use of human-machine interface in agricultural tractors equipped with Continuously Variable Transmission (CVT)

    Energy Technology Data Exchange (ETDEWEB)

    Caffaro, F.; Bisaglia, C.; Cutini, M.; Cremasco, M.M.; Cavallo, E.

    2017-07-01

    At the end of the 20th century the adoption of the Continuously Variable Transmission (CVT) was one of the disruptive technological advances in agricultural tractors. Several changes in the Human Machine Interface (HMI) of the tractor cab have been introduced to accommodate this technology. HMIs are known to raise issues about their ease of use; however, this topic has been under-investigated in the agricultural sector. The present study introduces a method to investigate the perceived ease of use of the HMI of agricultural tractors equipped with technological innovations. The HMI required to manage a CVT tractor was evaluated by sixteen tractor drivers (8 novices and 8 experts). During the first contact with the machine and after having performed two targeted tasks with the tractor, participants filled in a questionnaire about the ease of use of the controls and of the touch-screen display, and evaluated the general perception of ease of use, safety, quality and solidity of the machine. The trial pointed out some significant differences between novices and experts, thus confirming the validity of the proposed method. In particular, novice users showed some difficulties when interacting for the first time with the HMI of the CVT tractor working station, whereas experts did not report similar difficulties. Thus, expertise seems to play a role in determining the quality of the interaction with the HMI. Training interventions should be designed to help novices in increasing their expertise effectively, avoiding effort and errors and improving user’s comfort and system performance.

  18. W-026 acceptance test report system integration equipment (SIE)(submittal {number_sign} 018.6.A)

    Energy Technology Data Exchange (ETDEWEB)

    Watson, T.L.

    1997-01-27

    Acceptance testing of the System Integration Equipment (SIE) at Hanford was performed in two stages. The first was inconclusive, and resulted in a number of findings. These finding. are summarized as part of this report. The second stage of testing addressed these findings, and performed full system testing per the approved test procedure. This report includes summaries of all testing, results and finding.. Although the SIE did not in some cases perform as required for plant operations, it did perform per the system specification. (These discrepancies were noted and are addressed elsewhere.) Following testing, the system was formaLLy accepted. Documentation of this acceptance is incLuded in this report.

  19. Large scale access tests and online interfaces to ATLAS conditions databases

    International Nuclear Information System (INIS)

    Amorim, A; Lopes, L; Pereira, P; Simoes, J; Soloviev, I; Burckhart, D; Schmitt, J V D; Caprini, M; Kolos, S

    2008-01-01

    The access of the ATLAS Trigger and Data Acquisition (TDAQ) system to the ATLAS Conditions Databases sets strong reliability and performance requirements on the database storage and access infrastructures. Several applications were developed to support the integration of Conditions database access with the online services in TDAQ, including the interface to the Information Services (IS) and to the TDAQ Configuration Databases. The information storage requirements were the motivation for the ONline A Synchronous Interface to COOL (ONASIC) from the Information Service (IS) to LCG/COOL databases. ONASIC avoids the possible backpressure from Online Database servers by managing a local cache. In parallel, OKS2COOL was developed to store Configuration Databases into an Offline Database with history record. The DBStressor application was developed to test and stress the access to the Conditions database using the LCG/COOL interface while operating in an integrated way as a TDAQ application. The performance scaling of simultaneous Conditions database read accesses was studied in the context of the ATLAS High Level Trigger large computing farms. A large set of tests were performed involving up to 1000 computing nodes that simultaneously accessed the LCG central database server infrastructure at CERN

  20. Test equipment used for radiation protection type testing of aerosol filters at the National Board of Nuclear Safety and Radiation Protection (SAAS)

    International Nuclear Information System (INIS)

    Ullmann, W.; Przyborowski, S.

    1977-01-01

    Following a description of the overall design of test equipment developed in the SAAS for radiation protection type testing of aerosol filters, the most important physical and technical details concerning the preparation and measurement of test aerosols as well as the sampling procedure upstream and downstream of the filter to the tested, are comprehensively discussed. Furthermore, experiences gained during several years with different devices for mixing and diluting the aerosols are reported. (author)

  1. Evaluation of interface adhesion of hot-dipped zinc coating on TRIP steel with tensile testing and finite element calculation

    NARCIS (Netherlands)

    Song, G.M.; De Hosson, J.T.M.; Sloof, W.G.; Pei, Y.T.

    In this work, a methodology for the determination of the interface adhesion strength of zinc coating on TRIP steel is present. This method consists of a conventional tensile test in combination with finite element calculation. The relation between the average interface crack length and the applied

  2. Combining situated Cognitive Engineering with a novel testing method in a case study comparing two infusion pump interfaces

    NARCIS (Netherlands)

    Schnittker, R.; Schmettow, M.; Verhoeven, F.; Schraagen, J.M.C.

    2016-01-01

    We validated the usability of a new infusion pump interface designed with a situated Cognitive Engineering approach by comparing it to a reference interface using a novel testing method employing repeated measurements and process measures, in addition to traditional outcome measures. The sample

  3. Evaluation of climatic vibration testing on plastic waterproof enclosure for electronic equipment using ANSYS[reg] workbench

    International Nuclear Information System (INIS)

    Aw, K.C.; Huang, W.D.J.; De Silva, M.W.R.P.

    2007-01-01

    Designing and testing of waterproof enclosure for electronic equipment involves significant amount of time and resources. This paper concentrates on electronic equipment used for maritime application. Typical waterproof test perform is based on the IEC 60529 standards and is insufficient to determine its reliability. Since, these enclosures were subjected to environmental stress such as heat and vibration and there is a need to understand how these affect the waterproof performance. Simulation using ANSYS workbench software was performed to comprehend the effect of various parameters of accelerated testing performed on these waterproof enclosures. Experiments were performed to examine the correlation with simulation results. The results confirmed that accelerated testing with random vibration at cold temperature causes greatest stress and causes degradation to adhesive bonds and hence affect the waterproof performance

  4. Radon removal equipment based on aeration: A literature study of tests performed in Sweden between 1981 and 1996

    International Nuclear Information System (INIS)

    Mjoenes, L.

    2000-02-01

    In Sweden some principles to reduce the radon concentration in drinking water were tested in the beginning of the 1980s. Spray aeration under atmospheric pressure, diffused bubble aeration, aeration in the pressure tank and different combinations of these principles were studied. Aeration in the drill hole and adsorption on granulated activated char-coal were also tested. The best results, about 70 % reduction, were obtained with aeration in the pressure tank with a spray system combined with diffused air bubbling. The Oerebro project in the beginning of the 1990s included on site testing of five different aeration solutions: Aeration in the drill hole, aeration in the storage tank, ejector aeration, shallow tray aeration and packed column aeration. The radon removal efficiency varied between 20 % and 99 %. In 1994 a study intended to test the radon removal capacity of different water treatment equipment was performed. Six units of radon separators were included but most of the tested equipment was installed for other water treatment purposes. The performed measurements showed that the only types of equipment that reduce the radon concentration efficiently are radon separators and reverse osmosis filters. The radon removal capacity of the radon separators varied between 23 % and 97 %. In 1996 the nine most common radon separators on the Swedish market were tested. The results showed that the tested radon removal equipment worked well, although the technical quality and chosen technical solutions were not always the best. The radon removal capacity of the units participating in this test was in most cases between 96 and 99 %. In some cases the capacity exceeded 99 %. In order to reach this radon removal capacity the water must be recirculated in a storage tank under atmospheric pressure

  5. Opportunities for the Reduction of Substances and Equipment Impact on Personnel in Penetrant and Magnetic Particles Testing

    OpenAIRE

    Yaremenko, Yuriy

    2015-01-01

    Penetrant testing (PT) and magnetic particles inspection (MPI) are widespread methods of non-destructive testing which are not required a lot of investments for manual application and are simple in terms of discontinuous interpretation. On the other hand, work with chemicals requires special precautions, safety instructions and disposal limitations. Growing demand among customers to decrease impact of consumables and equipment on personnel and environment, shift producers’ priorities to devel...

  6. Radon removal equipment based on aeration: A literature study of tests performed in Sweden between 1981 and 1996

    Energy Technology Data Exchange (ETDEWEB)

    Mjoenes, L

    2000-02-01

    In Sweden some principles to reduce the radon concentration in drinking water were tested in the beginning of the 1980s. Spray aeration under atmospheric pressure, diffused bubble aeration, aeration in the pressure tank and different combinations of these principles were studied. Aeration in the drill hole and adsorption on granulated activated char-coal were also tested. The best results, about 70 % reduction, were obtained with aeration in the pressure tank with a spray system combined with diffused air bubbling. The Oerebro project in the beginning of the 1990s included on site testing of five different aeration solutions: Aeration in the drill hole, aeration in the storage tank, ejector aeration, shallow tray aeration and packed column aeration. The radon removal efficiency varied between 20 % and 99 %. In 1994 a study intended to test the radon removal capacity of different water treatment equipment was performed. Six units of radon separators were included but most of the tested equipment was installed for other water treatment purposes. The performed measurements showed that the only types of equipment that reduce the radon concentration efficiently are radon separators and reverse osmosis filters. The radon removal capacity of the radon separators varied between 23 % and 97 %. In 1996 the nine most common radon separators on the Swedish market were tested. The results showed that the tested radon removal equipment worked well, although the technical quality and chosen technical solutions were not always the best. The radon removal capacity of the units participating in this test was in most cases between 96 and 99 %. In some cases the capacity exceeded 99 %. In order to reach this radon removal capacity the water must be recirculated in a storage tank under atmospheric pressure.

  7. Robot services for elderly with cognitive impairment: testing usability of graphical user interfaces.

    Science.gov (United States)

    Granata, C; Pino, M; Legouverneur, G; Vidal, J-S; Bidaud, P; Rigaud, A-S

    2013-01-01

    Socially assistive robotics for elderly care is a growing field. However, although robotics has the potential to support elderly in daily tasks by offering specific services, the development of usable interfaces is still a challenge. Since several factors such as age or disease-related changes in perceptual or cognitive abilities and familiarity with computer technologies influence technology use they must be considered when designing interfaces for these users. This paper presents findings from usability testing of two different services provided by a social assistive robot intended for elderly with cognitive impairment: a grocery shopping list and an agenda application. The main goal of this study is to identify the usability problems of the robot interface for target end-users as well as to isolate the human factors that affect the use of the technology by elderly. Socio-demographic characteristics and computer experience were examined as factors that could have an influence on task performance. A group of 11 elderly persons with Mild Cognitive Impairment and a group of 11 cognitively healthy elderly individuals took part in this study. Performance measures (task completion time and number of errors) were collected. Cognitive profile, age and computer experience were found to impact task performance. Participants with cognitive impairment achieved the tasks committing more errors than cognitively healthy elderly. Instead younger participants and those with previous computer experience were faster at completing the tasks confirming previous findings in the literature. The overall results suggested that interfaces and contents of the services assessed were usable by older adults with cognitive impairment. However, some usability problems were identified and should be addressed to better meet the needs and capacities of target end-users.

  8. Estimation of carrier mobility at organic semiconductor/insulator interface using an asymmetric capacitive test structure

    Directory of Open Access Journals (Sweden)

    Rajesh Agarwal

    2016-04-01

    Full Text Available Mobility of carriers at the organic/insulator interface is crucial to the performance of organic thin film transistors. The present work describes estimation of mobility using admittance measurements performed on an asymmetric capacitive test structure. Besides the advantage of simplicity, it is shown that at low frequencies, the measured capacitance comes from a large area of channel making the capacitance-voltage characteristics insensitive to contact resistances. 2-D numerical simulation and experimental results obtained with Pentacene/Poly(4-vinyphenol system are presented to illustrate the operation and advantages of the proposed technique.

  9. Development of corrosion testing equipment under heat transfer and irradiation conditions to evaluate corrosion resistance of materials used in acid recovery evaporator. Contract research

    International Nuclear Information System (INIS)

    Motooka, Takafumi; Numata, Masami; Kiuchi, Kiyoshi

    2002-01-01

    We have been evaluated the safety for corrosion of various metals applied to acid recovery evaporators by the mock-up tests using small scaled equipment and the reference tests in laboratories with small specimens. These tests have been conducted under-radioactive environment. The environment in practical reprocessing plants has many radioactive species. Therefore, the effect of irradiation on corrosion should be evaluated in detail. In this study, we have developed the corrosion testing equipment, which is employed to simulate environments in the acid recovery evaporators. This report describes the specification of corrosion testing equipment and the results of primary, reference and hot tests. Using the equipment, the corrosion test under heat transfer and irradiation conditions have been carried out for 930 hours in safety. It is expectable that useful corrosion test data in radioactive environment are accumulated with this equipment in future, and help the adequate choice of corrosion test condition in laboratories. (author)

  10. The fracture strength by a torsion test at the implant-abutment interface.

    Science.gov (United States)

    Watanabe, Fumihiko; Hiroyasu, Kazuhiko; Ueda, Kazuhiko

    2015-12-01

    Fractured connections between implants and implant abutments or abutment screws are frequently encountered in a clinical setting. The purpose of this study was to investigate fracture strength using a torsion test at the interface between the implant and the abutment. Thirty screw-type implant with diameters of 3.3, 3.8, 4.3, 5.0, and 6.0 mm were submitted to a torsion test. Implants of each size were connected to abutments with abutment screws tightened to 20 N · cm. Mechanical stress was applied with a rotational speed of 3.6 °/min until fracture occurred, and maximum torque (fracture torque) and torsional yield strength were measured. The mean values were calculated and then compared using Tukey's test. The abutments were then removed, and the implant-abutment interfaces were examined using a scanning electron microscope (SEM). No significant differences in mean fracture torque were found among 3.3, 3.8, and 4.3 mm-diameter implants, but significant differences were found between these sizes and 5.0 and 6.0 mm-diameter implants (p abutment corresponding to the internal notches of the implant body had been destroyed. Smaller diameter implants demonstrated lower fracture torque and torsional yield strength than implants with larger diameters. In internal tube-in-tube connections, three abutment projections corresponding to rotation-prevention notches were destroyed in each implant.

  11. A method to evaluate the perceived ease of use of human-machine interface in agricultural tractors equipped with Continuously Variable Transmission (CVT

    Directory of Open Access Journals (Sweden)

    Federica Caffaro

    2018-02-01

    Full Text Available At the end of the 20th century the adoption of the Continuously Variable Transmission (CVT was one of the disruptive technological advances in agricultural tractors. Several changes in the Human Machine Interface (HMI of the tractor cab have been introduced to accommodate this technology. HMIs are known to raise issues about their ease of use; however, this topic has been under-investigated in the agricultural sector. The present study introduces a method to investigate the perceived ease of use of the HMI of agricultural tractors equipped with technological innovations. The HMI required to manage a CVT tractor was evaluated by sixteen tractor drivers (8 novices and 8 experts. During the first contact with the machine and after having performed two targeted tasks with the tractor, participants filled in a questionnaire about the ease of use of the controls and of the touch-screen display, and evaluated the general perception of ease of use, safety, quality and solidity of the machine. The trial pointed out some significant differences between novices and experts, thus confirming the validity of the proposed method. In particular, novice users showed some difficulties when interacting for the first time with the HMI of the CVT tractor working station, whereas experts did not report similar difficulties. Thus, expertise seems to play a role in determining the quality of the interaction with the HMI. Training interventions should be designed to help novices in increasing their expertise effectively, avoiding effort and errors and improving user’s comfort and system performance.

  12. Strain Gage Load Calibration of the Wing Interface Fittings for the Adaptive Compliant Trailing Edge Flap Flight Test

    Science.gov (United States)

    Miller, Eric J.; Holguin, Andrew C.; Cruz, Josue; Lokos, William A.

    2014-01-01

    This is the presentation to follow conference paper of the same name. The adaptive compliant trailing edge (ACTE) flap experiment safety of flight requires that the flap to wing interface loads be sensed and monitored in real time to ensure that the wing structural load limits are not exceeded. This paper discusses the strain gage load calibration testing and load equation derivation methodology for the ACTE interface fittings. Both the left and right wing flap interfaces will be monitored and each contains four uniquely designed and instrumented flap interface fittings. The interface hardware design and instrumentation layout are discussed. Twenty one applied test load cases were developed using the predicted in-flight loads for the ACTE experiment.

  13. Testing of wet scrap recovery equipment for mixed oxide scrap reprocessing

    International Nuclear Information System (INIS)

    Demiter, J.A.; Klem, M.J.; Owen, T.J.

    1984-08-01

    The Wet Scrap Recovery (WSR) program was initiated at the Hanford Engineering Development Laboratory (HEDL) by Westinghouse Hanford Company in Richland, Washington to demonstrate fuel fabrication scrap recovery and reconversion to fuel grade oxide powder using the continuous coprecipitation-calcination (COPRECAL) conversion process. Advancements in process control equipment and instrumentation were also developed and demonstrated

  14. 78 FR 64295 - Energy Conservation Program: Test Procedure for Commercial Refrigeration Equipment

    Science.gov (United States)

    2013-10-28

    ... they are consumer products or commercial and industrial equipment. Under 42 U.S.C. 6314(c)(1), no later... requirements a consumer would expect. DOE requests comment on the proposed definition for chef base or griddle... projection is normal to the plane of the door, and the way customers typically view products through the door...

  15. RESUME-95: Results of an International Field Test of Mobile Equipment for Emergency Response

    DEFF Research Database (Denmark)

    Hovgaard, Jens; Scott, Marian

    1997-01-01

    In 1995 the exercise RESUME-95 (Rapid Environmental Surveying Using Mobile Equipment) took place in Finland. Groups from 8 European countries joined the exercise. The methods used were airborne gamma-ray measurements, car-borne measurements and in situ stationary measurements. The results of the ...

  16. Manufacture research of the test equipment to measure the dose rate in high radiation medium

    International Nuclear Information System (INIS)

    Phan Luong Tuan; Nguyen Van Sy; Nguyen Xuan Vinh; Dang Quang Bao; Nguyen Thanh Hung; Pham Minh Duc; Nguyen Xuan Truong

    2017-01-01

    Photodiode BPW34 is operated as a low voltage counter tubes. When the radiation rays go into the BPW34,they will create a pairs of electron and hole. If setting the reverse bias in to the BPW34, a pulse is achieved and it can be amplified and processed. The STM32 is the microcontroller family which is developed base on ARM processors. The STM32 incorporated many new features such as ADC, I2C, etc. With the connectional ability to other devices, the STM32 is proving its advantages in the development of equipment.The application of irradiation technology in the economy-society increases widespread as food irradiation, mutant irradiation, etc. Until now the calculation the high dose rate at Hanoi Irradiation Center is identified by the Fricke, ECB dosimeters. The dosimeters must be destroyed in order to serve for dose rate determination. Manufacture research the equipment for dose rate calculation support to determine dose rate directly through the equipment’s signal and this equipment can be used multiple. This equipment can be connected to other devices to control the irradiation process better via signals. (author)

  17. Gas Atomization Equipment Statement of Work and Specification for Engineering design, Fabrication, Testing, and Installation

    Energy Technology Data Exchange (ETDEWEB)

    Boutaleb, T. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Pluschkell, T. P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-11-30

    The Gas Atomization Equipment will be used to fabricate metallic powder suitable for Powder Bed Fusion additive Manufacturing material to support Lawrence Livermore National Laboratory (LLNL) research and development. The project will modernize our capabilities to develop spherical reactive, refractory, and radioactive powders in the 10-75 μm diameter size range at LLNL.

  18. 77 FR 10291 - Energy Conservation Program: Test Procedure for Commercial Refrigeration Equipment

    Science.gov (United States)

    2012-02-21

    ... Volume and Total Shelf Area of Household Refrigerators and Household Wine Chillers''; and sections 5.1..., some equipment is designed for storing goods such as wine, candy, and flowers at temperatures that are..., No. 19 at p. 145), and offered that night curtains could provide benefits for doored cases. (Zero...

  19. Results from the Operational Testing of the General Electric Smart Grid Capable Electric Vehicle Supply Equipment (EVSE)

    Energy Technology Data Exchange (ETDEWEB)

    Carlson, Richard Barney [Idaho National Lab. (INL), Idaho Falls, ID (United States); Scoffield, Don [Idaho National Lab. (INL), Idaho Falls, ID (United States); Bennett, Brion [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2013-12-01

    The Idaho National Laboratory conducted testing and analysis of the General Electric (GE) smart grid capable electric vehicle supply equipment (EVSE), which was a deliverable from GE for the U.S. Department of Energy FOA-554. The Idaho National Laboratory has extensive knowledge and experience in testing advanced conductive and wireless charging systems though INL’s support of the U.S. Department of Energy’s Advanced Vehicle Testing Activity. This document details the findings from the EVSE operational testing conducted at the Idaho National Laboratory on the GE smart grid capable EVSE. The testing conducted on the EVSE included energy efficiency testing, SAE J1772 functionality testing, abnormal conditions testing, and charging of a plug-in vehicle.

  20. Approach to the assessment of the performance of nondestructive test methods in the manufacture of nuclear power station equipment

    International Nuclear Information System (INIS)

    Michaut, J.P.

    1996-01-01

    The safety of a nuclear power station lies largely in the possibility of ensuring, at the time of in service inspections on major equipment, that the extent of faults which may appear or develop is not greater than that of faults detrimental to behavior in service. This assurance is based on performance demonstration of the nondestructive test methods used for inspecting the equipment in service. This is the subject of numerous studies in various countries. To ensure that manufacturing faults likely to downgrade the safety of the equipment are not discovered in service, it seems desirable to make sure that the performance of the nondestructive test (NDT) methods which are going to be used in manufacture will be at least as high as those used in service and that they are therefore capable of guaranteeing detection of faults clearly less important than really harmful faults. The performance of NDT methods and their consistency with those which can be used in service is evaluated before the start of manufacture on a mock-up representative of the equipment itself. Information is given on research in progress on the bimetal welding of a pressurizer spray nozzle

  1. Strain transfer through film-substrate interface and surface curvature evolution during a tensile test

    Science.gov (United States)

    He, Wei; Han, Meidong; Goudeau, Philippe; Bourhis, Eric Le; Renault, Pierre-Olivier; Wang, Shibin; Li, Lin-an

    2018-03-01

    Uniaxial tensile tests on polyimide-supported thin metal films are performed to respectively study the macroscopic strain transfer through an interface and the surface curvature evolution. With a dual digital image correlation (DIC) system, the strains of the film and the substrate can be simultaneously measured in situ during the tensile test. For the true strains below 2% (far beyond the films' elastic limit), a complete longitudinal strain transfer is present irrespective of the film thickness, residual stresses and microstructure. By means of an optical surface profiler, the three-dimensional (3D) topography of film surface can be obtained during straining. As expected, the profile of the specimen center remains almost flat in the tensile direction. Nevertheless, a relatively significant curvature evolution (of the same order with the initial curvature induced by residual stresses) is observed along the transverse direction as a result of a Poisson's ratio mismatch between the film and the substrate. Furthermore, finite element method (FEM) has been performed to simulate the curvature evolution considering the geometric nonlinearity and the perfect strain transfer at the interface, which agrees well with the experimental results.

  2. CV equipment responsibilities

    CERN Document Server

    Pirollet, B

    2008-01-01

    This document describes the limits of the responsibilities of the TS/CV for fire fighting equipment at the LHC. The various interfaces, providers and users of the water supply systems and clean water raising systems are described.

  3. A test specimen for characterizing the fracture energy of interfaces in composites

    International Nuclear Information System (INIS)

    Shaw, L.; Abbaschian, R.

    1993-01-01

    A sandwich-type chevron-notched specimen, which has a phase angle of loading near zero, is proposed to measure interfacial fracture energy arising mainly from chemical bonding. With the specimen configuration of this kind, the advantages from both sandwich test specimens and chevron-notched specimens can be combined to provide an easy and accurate test for the measurement of interfacial fracture energy. The validity of the specimen has been analyzed in terms of the mechanics of sandwich-type specimens and chevron-notched specimens, and demonstrated using the Al 2 O 3 /Nb bimaterial system. The results show that for a phase angle of loading around -7 degrees the Al 2 O 3 /Nb interface has a fracture energy of 9.3 ± 0.2 J/m 2 . 39 refs

  4. Testing and interfacing intelligent power supplies for the Los Alamos National Laboratory Accelerator Complex

    International Nuclear Information System (INIS)

    Sturrock, J.C.; Cohen, S.; Weintraub, B.L.; Hayden, D.J.; Archuleta, S.F.

    1992-01-01

    New high-current, high-precision microprocessor-controlled power supplies, built by Alpha Scientific Electronics of Hayward, CA, have been installed at the Los Alamos National Laboratory Accelerator Complex. Each unit has sophisticated microprocessor control on-board and communicates via RS-422 (serial communications). The units use a high level ASCII-based control protocol. Performance tests were conducted to verify adherence to specification and to ascertain ultimate long-term stability. The ''front-end'' software used by the accelerator control system has been written to accommodate these new devices. The supplies are interfaced to the control system through a terminal server port connected to the site-wide ediernet backbone. Test design and results as well as details of the software implementation for the analog and digital control of the supplies through the accelerator control system are presented

  5. ITER L 7 duct remote handling equipment design report

    International Nuclear Information System (INIS)

    Millard, J.

    1996-09-01

    The operation, design and interfaces of the 'Duct Vehicle' and it's associated remote handling equipment are briefly described in this document. This equipment is being designed by Spar Aerospace Ltd. for the Divertor Test Platform as part of ITER Research and Development Project L-7. Canadian Fusion Fuels Technology Project funds this work as part of the Canadian Contribution to ITER. This document describes the equipment design status at the September 1996 design review. 23 figs

  6. Vacuum-to-air interface for the advanced test accelerator beam director

    International Nuclear Information System (INIS)

    Cruz, G.E.; Edwards, W.F.; Kavanagh, D.P.; Addis, R.B.; Weiss, W.C.; Livenspargar, C.M.

    1986-01-01

    A vacuum-to-air transition was created to facilitate the Lawrence Livermore National Laboratory's Advanced Test Accelerator (ATA) electron beam 1-Hz pulse rate. It is necessary that a pulsed particle beam go from a region at 10 -6 torr through a 1-cm-diam maximum aperture into a region at 760 torr. This must be accomplished without the use of windows or solid barriers. Two tests will be conducted on the vacuum-to-air interface. The first determines pressure profiles through 1.0-mm- and 10.0-mm-diam orifices. The second test employs an expendable foil and foil advancement mechanism. In this paper, the experimental results of the orifice test are presented and the analytical results are compared with the empirical results. The foil advancement test will be documented after the test is completed. The mechanism serves both as an orifice and as a fast-acting vacuum valve. In operation, the electron beam penetrates the thin foil, thereby creating an aperture of minimum geometry. During the balance of the pulse cycle, after the beam duration, the foil is advanced to seal the opening and recover the almost negligible loss in vacuum

  7. Cold Regions Logistic Supportability Testing of Construction, Support and Service Equipment.

    Science.gov (United States)

    1985-06-25

    1985 APPENDIX B - POST-TEST CHECKLIST 1. Have test data been collected, recorded, and presented in accordance . with this TOP? YES NO . Comment : 2...planning? YES NO . Comment : 5. Were the test results compromised in any way due to test performance procedures? YES NO . Comment : 6. Were the test results...compromised in any way due to test control pro- - cedures? YES NO Comment : 7. Were the test results compromised in any way due to data collection

  8. 77 FR 9859 - Lifesaving Equipment: Production Testing and Harmonization With International Standards

    Science.gov (United States)

    2012-02-21

    ... Prototype testing.... Manufacturers must obtain Units with rated All tests use the Units with rated (160.151... Liferafts Prototype testing.... Existing Certificates of No cost or benefit as All tests use the Costs of... designs, overseeing prototype construction, witnessing prototype testing, and monitoring production of the...

  9. Procedure for field axes measurement, beam indication adjustment, and figure of convergence determination within performance tests for radiation therapy equipment

    Energy Technology Data Exchange (ETDEWEB)

    Quast, U; Krause, K; Rassow, J [Essen Univ. (Gesamthochschule) (Germany, F.R.). Abt. fuer Klinische Strahlenphysik

    1976-09-01

    A routine measuring procedure for the verification of radiation field axes and figure of convergence within a spatial resolution of +- 0.5 mm is described. Measurements are done in two parallel planes in a certain distance before and behind the presumed isocentre. The used test arrangement permits rapid check and controlled adjustment of the alignment of beam or isocentre indicating devices for all isocentric radiation therapy equipment.

  10. Performance Test of the Salt transfer and Pellet fabrication of UCl{sub 3} Making Equipment for Electrorefining

    Energy Technology Data Exchange (ETDEWEB)

    Woo, M. S.; Jin, H. J.; Park, G. I.; Park, S. B. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-05-15

    The process to produce a uranium chloride salt includes two steps: a reaction process of gaseous chlorine with liquid cadmium to form the CdCl{sub 2} occurring in a Cd layer, followed by a process to produce UCl{sub 3} by the reaction of U in the LiCl-KCl eutectic salt and CdCl{sub 2}. Chemical reaction is next chlorination reaction; - Cd chlorination : Cd + Cl2 → CdCl{sub 2} - U chlorination : 3CdCl2 + 2U → 3Cd + 2UCl{sub 3} The apparatus for producing UCl{sub 3} consists of a chlorine gas generator, a uranium chlorinator, a Cd distiller, the pelletizer, a off-gas wet scrubber and a dry scrubber. Salt transfer system set among reactors to transfer salt at 500 .deg. C. The temperature of the reactants is maintained at about 600 .deg. C. After the reaction is completed in the uranium chlorinator, The Salt product is transferred to the Cd distiller to decrease residual Cd concentration in the salts, and then salt is transferred to the mould of pelletizer by a transfer system to fabricate pellet type salt. Performance test of the salt transfer and pellet fabrication of its equipment was tested in this work. Performance test of the salt transfer and pellet fabrication of UCl3 making equipment for Electrorefining carried out in this work. The result of equipment test is that melted salt at 600 .deg. C was easy transferred by salt transfer equipment heated at 500 .deg. C. In this time, salt transfer was carried out by argon gas pressurization at 3bar. When velocity of salt transfer was controlled under reduce pressure, velocity of salt transfer was difficult to control. And when salt pellet was fabricated by the mold of pelletizer heated at 90 .deg. C better than mold of pelletizer heated at 200 .deg. C because salt melted prevent leakage from mold of pelletizer.

  11. Design of electronic measurement and quench detection equipment for the Current Lead Test facility Karlsruhe (CuLTKa)

    International Nuclear Information System (INIS)

    Hollik, Markus; Fietz, Walter H.; Fink, Stefan; Gehrlein, Mirko; Heller, Reinhard; Lange, Christian; Möhring, Tobias

    2013-01-01

    The Current Lead Test facility Karlsruhe (CuLTKa) is under construction at the Karlsruhe Institute of Technology (KIT) to perform acceptance tests of high temperature superconductor (HTS) current leads (CL). CuLTKa is in progress and present planning expects the completion in 2013. The data acquisition system is based on a modular design with electronic measurement and monitoring equipment covering a test voltage of 50 kV DC against ground. It provides plug-in units which enable temperature and voltage measurement at high voltage potential and in addition quench detection units which detect a loss of superconductivity reliably and quickly to avoid damage of the superconducting device under test. Prototype units for quench detection, temperature and voltage measurement have been successfully tested. Six temperature measurement units are already in use in the KIT test facility TOSKA and operated reliably during the acceptance tests of the HTS current leads for Wendelstein 7-X (W7-X) in 2011/2012. CuLTKa will be used first for 26 current leads which will be built in KIT for the fusion experiment JT-60SA. The present paper gives an overview of the design of the electronic measurement and quench detection equipment

  12. Equipment for testing a group of nuclear reactor fuel elements for damage to the cans

    International Nuclear Information System (INIS)

    Mohm, F.

    1977-01-01

    Equipment is described for use in sodium cooled nuclear reactors, with which the fuel elements consisting of bundles of fuel and fertile rods can be examined for damage to the cans. Fission poducts occurring in the liquid coolant act as indicators. The coolant is sucked via pipelines which penetrate into the elements into a collecting container, and a special pipeline is available for every element of a group, where the highest points of individual pipelines at different hydrostatic heads are taken to the collecting container. This permits the checking of one line at a time due to pressure changes. (UWI) [de

  13. 40 CFR 1068.210 - What are the provisions for exempting test engines/equipment?

    Science.gov (United States)

    2010-07-01

    ... following things: (1) Show that the proposed test program has a valid purpose under paragraph (a) of this... at least the following things: (i) The technical nature of the test. (ii) The test site. (iii) The... testing exemption, we will send you a letter or a memorandum for your signature describing the basis and...

  14. The Equipment of Using AZOLLA for O2-Supplimentation and its Test

    Science.gov (United States)

    Liu, Xia-Shi; Chen, Min; Bian, Zu-Liang; Liu, Chung-Chu

    The water-consuming amount in a long-term astro-navigation is large. In order to reduce the burden of water supply from Earth ground, the space station needs to resolve the problems of water supply. For this reason, the recovery and regeneration of urine solution of spacemen, and its utilization possess a key importance. Many investigations on this aspect have been reported. Our research based on "biological absorption-purification-UV photocatalytic oxidation" techniques with a relevant treating equipment that for a comprehensive treatment to fresh urine of spacemen has been created. In this equipment, the urine solution was used as the nutrient solution for the biological parts in ecological life ensurant system, after absorbing the nutrient, it was decomposed, metabolized and purified in some distance, and created a favorable condition for the follow-up oxidation treatment by UV-Photocatalytic Oxidation. After these two processes, the treated urine solution reached the GB5749-85 standard of water quality. Some main indexes are as table one. Chroma<5-15 Feculent degree-NTU-1.20-3 --5 Total rigidity-according to CaCO3-mg/L-3.60-450 N-NO3--mg/L-0.60-20 Soluble total solid-mg/L-543-1000 Bacterial gross-cfu/ml-13-100 Coliform group-No./L-<3-3 Key words-Photocatalytic Oxidation , Ultraviolet

  15. The pharmaceutical vial capping process: Container closure systems, capping equipment, regulatory framework, and seal quality tests.

    Science.gov (United States)

    Mathaes, Roman; Mahler, Hanns-Christian; Buettiker, Jean-Pierre; Roehl, Holger; Lam, Philippe; Brown, Helen; Luemkemann, Joerg; Adler, Michael; Huwyler, Joerg; Streubel, Alexander; Mohl, Silke

    2016-02-01

    Parenteral drug products are protected by appropriate primary packaging to protect against environmental factors, including potential microbial contamination during shelf life duration. The most commonly used CCS configuration for parenteral drug products is the glass vial, sealed with a rubber stopper and an aluminum crimp cap. In combination with an adequately designed and controlled aseptic fill/finish processes, a well-designed and characterized capping process is indispensable to ensure product quality and integrity and to minimize rejections during the manufacturing process. In this review, the health authority requirements and expectations related to container closure system quality and container closure integrity are summarized. The pharmaceutical vial, the rubber stopper, and the crimp cap are described. Different capping techniques are critically compared: The most common capping equipment with a rotating capping plate produces the lowest amount of particle. The strength and challenges of methods to control the capping process are discussed. The residual seal force method can characterize the capping process independent of the used capping equipment or CCS. We analyze the root causes of several cosmetic defects associated with the vial capping process. Copyright © 2015 Elsevier B.V. All rights reserved.

  16. Nuclear electronic equipment for control and monitoring panel. Procedure guide for on-site tests of nuclear reactor instruments

    International Nuclear Information System (INIS)

    1975-10-01

    By the use of a procedure for on-site testing of nuclear reactor instruments it should be possible to judge their ability to guarantee the reactor safety and availability at the moment of divergence or during operation. Such a procedure must therefore be created as a work implement for the quick and reliable installation of electronic devices necessary for nuclear reactor control and supervision. A standard document is proposed for this purpose, allowing a ''test programme'' to be set up before the equipment is installed on the site [fr

  17. Hamamatsu C11204-01 calibration, test and design of a dedicated LabVIEW interface

    International Nuclear Information System (INIS)

    Nocerino, E.; Barbato, F.C.T.; De Asmundis, R.

    2017-01-01

    In the last 50 years solid state devices have been widely used as radiation detectors (photons, betas, fast electrons and heavy ions) thanks to the advantages they offer with respect to photomultiplier tubes technology. However, despite their benefits (low power consumption, small size, low costs), semiconductors are very sensitive to temperature variations. This means that for those experiments using solid state detectors without any thermal control, the correct operation of the detectors is affected by the environmental condition. To solve this problem Hamamatsu Photonics realized the C11204-01 device: a special voltage supply module for silicon photomultipliers which compensates the overvoltage at different temperatures. In the following work we present the results of the calibration of this device and a test we performed on a silicon photomultiplier, by means of a LabVIEW"T"M interface designed ad hoc for this purpose.

  18. Rolling contact fatigue in a vacuum test equipment and coating analysis

    CERN Document Server

    Danyluk, Michael

    2014-01-01

    This book deals with wear and performance testing of thin solid film lubrication and hard coatings in an ultra-high vacuum (UHV), a process which enables rapid accumulation of stress cycles compared with testing in oil at atmospheric pressure. The authors' lucid and authoritative narrative broadens readers' understanding of the benefits of UHV testing: a cleaner, shorter test is achieved in high vacuum, disturbance rejection by the deposition controller may be optimized for maximum fatigue life of the coating using rolling contact fatigue testing (RCF) in a high vacuum, and RCF testing in UHV

  19. Method of boundary testing of the electric circuits and its application for calculating electric tolerances. [electric equipment tests

    Science.gov (United States)

    Redkina, N. P.

    1974-01-01

    Boundary testing of electric circuits includes preliminary and limiting tests. Preliminary tests permit determination of the critical parameters causing the greatest deviation of the output parameter of the system. The boundary tests offer the possibility of determining the limits of the fitness of the system with simultaneous variation of its critical parameters.

  20. Design Study and Optimization of Irradiation Facilities for Detector and Accelerator Equipment Testing in the SPS North Area at CERN

    CERN Document Server

    AUTHOR|(CDS)2079748; Stekl, Ivan

    Due to increasing performance of LHC during the last years, the strong need of new detector and electronic equipment test areas at CERN appeared from user communities. This thesis reports on two test facilities: GIF++ and H4IRRAD. GIF++, an upgrade of GIF facility, is a combined high-intensity gamma and particle beam irradiation facility for testing detectors for LHC. It combines a high-rate 137Cs source, providing photons with energy of 662 keV, together with the high-energy secondary particle beam from SPS. H4IRRAD is a new mixed-field irradiation area, designed for testing LHC electronic equipment for radiation damage effects. In particular, large volume assemblies such as full electronic racks of high current power converters can be tested. The area uses alternatively an attenuated primary 400 GeV/c proton beam from SPS, or a secondary, mainly proton, beam of 280 GeV/c directed towards a copper target. Different shielding layers are used to reproduce a radiation field similar to the LHC “tunnel” and �...

  1. Ammunition Peculiar Equipment (APE) 1995, NIR Propellant Analyzer, to MIL-STD-398, Military Standard Shields, Operational for Ammunition Operations, Criteria for Design of and Tests for Acceptance

    National Research Council Canada - National Science Library

    2003-01-01

    ... (SJMAC-DEM) to test the Ammunition Peculiar Equipment (APE) 1995 NIR Propellant Analyzer, to MIL-STD-398, "Military Standard Shields, Operational for Ammunition Operations, Criteria for Design of and Tests for Acceptance...

  2. FEATURES OF RESOURCE TESTING OF THE HYDRAULIC BRAKE DRIVE ELEMENTS OF VEHICLES EQUIPPED WITH ABS

    Directory of Open Access Journals (Sweden)

    A. Revin

    2011-01-01

    Full Text Available The analysis of the resource testing facilities and methods of automobile brake cylinders in terms of ABS working process adequacy is carried out. A testing stand construction and a method of carrying out the resource testing of hydraulic drive elements of the automobile automated braking sys-tem is offered.

  3. Validation of the Operating and Support Cost Model for Avionics Automatic Test Equipment (OSCATE).

    Science.gov (United States)

    1980-06-01

    AFLCR 65-1 (56) DOD 4140 -32 (74) CODES DATA LISTED BY. ALC code, Division Code, Equipment Specialist Code, NSN DATA ORDERING SEQUENCEs This data is...PAJ6A 4140 -01-043-5035 .... IL0UERft1TfR 1002 1 319.55 22720 1 0 0 1003 0 14.55 0 0 0 10.00 0 0 1004 0 0 32.454 16.42 0 0 0 0 0 0 0 127 1101 PAJHA 4920...5320 480 CONTINUE 5330 60 To 150 5340 5350C *...*~****.*.s*..** 5360C *****eOUTPUT OPTION 7 5370C e**ss*** sae ******* 5380 500 PRINT 510 5390 510

  4. Instrument Control (iC) – An Open-Source Software to Automate Test Equipment

    Science.gov (United States)

    Pernstich, K. P.

    2012-01-01

    It has become common practice to automate data acquisition from programmable instrumentation, and a range of different software solutions fulfill this task. Many routine measurements require sequential processing of certain tasks, for instance to adjust the temperature of a sample stage, take a measurement, and repeat that cycle for other temperatures. This paper introduces an open-source Java program that processes a series of text-based commands that define the measurement sequence. These commands are in an intuitive format which provides great flexibility and allows quick and easy adaptation to various measurement needs. For each of these commands, the iC-framework calls a corresponding Java method that addresses the specified instrument to perform the desired task. The functionality of iC can be extended with minimal programming effort in Java or Python, and new measurement equipment can be addressed by defining new commands in a text file without any programming. PMID:26900522

  5. Instrument Control (iC) - An Open-Source Software to Automate Test Equipment.

    Science.gov (United States)

    Pernstich, K P

    2012-01-01

    It has become common practice to automate data acquisition from programmable instrumentation, and a range of different software solutions fulfill this task. Many routine measurements require sequential processing of certain tasks, for instance to adjust the temperature of a sample stage, take a measurement, and repeat that cycle for other temperatures. This paper introduces an open-source Java program that processes a series of text-based commands that define the measurement sequence. These commands are in an intuitive format which provides great flexibility and allows quick and easy adaptation to various measurement needs. For each of these commands, the iC-framework calls a corresponding Java method that addresses the specified instrument to perform the desired task. The functionality of iC can be extended with minimal programming effort in Java or Python, and new measurement equipment can be addressed by defining new commands in a text file without any programming.

  6. Equipment for long-term testing of material creep in liquid sodium

    International Nuclear Information System (INIS)

    Dufek, F.; Walder, V.; Cech, V.; Winkler, P.

    1980-01-01

    A sodium test plant is described and the methods are shown of securing the desired test specifications. The facility is used for the long-term testing of nonsteady material creep under the action of temperature and mechanical stress due to the static or pulsed overpressure of inert gas inside a tube specimen and a simultaneous effect of sodium flow on the outside wall. The test results are to be used for comparing Czechoslovak-made steels with foreign materials and also for testing the degradation effects of the above phenomena on the standardized long-term properties in inert and steady state conditions. (B.S.)

  7. The automated testing system of programs with the graphic user interface within the context of educational process

    OpenAIRE

    Sychev, O.; Kiryushkin, A.

    2009-01-01

    The paper describes the problems of automation of educational process at the course "Programming on high level language. Algorithmic languages". Complexities of testing of programs with the user interface are marked. Existing analogues was considered. Methods of automation of student's jobs testing are offered.

  8. The use of fuzzy logic in quality control testing of automotive and tractor equipment

    OpenAIRE

    Korobko А.; Mykhailova О.; Nazarko О.; Radchenko Yu.

    2016-01-01

    The article analyzes the relevance of the research topics, defines goals and objectives, subject and object of research. On the basis of the literature analysis, the following eduction was made: not all the test methods in road and agricultural vehicles (tractors) contribute to the effective implementation of the requirements of normative documents including international, inter-laboratory comparative tests. The approach in laboratory testing to the synthesis adaptive system of metrological a...

  9. The research of the test-class method based on interface object in the software integration test of the large container inspection system

    International Nuclear Information System (INIS)

    Sun Shaohua; Chen Zhiqiang; Zhang Li; Gao Wenhuan; Kang Kejun

    2000-01-01

    Software test is the important stage in software process. The has been mature theory, method and model for unit test in practice. But for integration test, there is not regular method to adhere to. The author presents a new method, developed during the development of the large container inspection system, named test class method based on interface object. In this method a set of basic test-class based on the concept of class in the object-oriented method is established and the method of combining the interface graph and the class set is used to describe the test process. So the strict control and the scientific management for the test process are achieved. The conception of test database is introduced in this method, thus the traceability and the repeatability of test process are improved

  10. The research of the test-class method based on interface object in the software integration test of the large container inspection system

    International Nuclear Information System (INIS)

    Sun Shaohua; Chen Zhiqiang; Zhang Li; Gao Wenhuan; Kang Kejun

    2001-01-01

    Software test is the important stage in software process. There has been mature theory, method and model for unit test in practice. But for integration test, there is not regular method to adhere to. The author presents a new method, developed during the development of the large container inspection system, named test-class method based on interface object. A set of basis test-class based on the concept of class in the object-oriented method is established and the method of combining the interface graph and the class set is used to describe the test process. So the strict control and the scientific management for the test process are achieved. The conception of test database is introduced in this method, thus the traceability and the repeatability of test process are improved

  11. 40 CFR 85.2231 - On-board diagnostic test equipment requirements.

    Science.gov (United States)

    2010-07-01

    ... PROGRAMS (CONTINUED) CONTROL OF AIR POLLUTION FROM MOBILE SOURCES Emission Control System Performance... evaluation status of supported monitors (test complete/test not complete) in Mode $01 PID $01, as well as be... have the capability to include bi-directional communication for control of the evaporative canister...

  12. Failure analysis on false call probe pins of microprocessor test equipment

    Science.gov (United States)

    Tang, L. W.; Ong, N. R.; Mohamad, I. S. B.; Alcain, J. B.; Retnasamy, V.

    2017-09-01

    A study has been conducted to investigate failure analysis on probe pins of test modules for microprocessor. The `health condition' of the probe pin is determined by the resistance value. A test module of 5V power supplied from Arduino UNO with "Four-wire Ohm measurement" method is implemented in this study to measure the resistance of the probe pins of a microprocessor. The probe pins from a scrapped computer motherboard is used as the test sample in this study. The functionality of the test module was validated with the pre-measurement experiment via VEE Pro software. Lastly, the experimental work have demonstrated that the implemented test module have the capability to identify the probe pin's `health condition' based on the measured resistance value.

  13. UsiGesture: Test and Evaluation of an Environment for Integrating Gestures in User Interfaces

    OpenAIRE

    Beuvens, François; Vanderdonckt, Jean

    2014-01-01

    User interfaces allowing gesture recognition and manipulation are becoming more and more popular these last years. It however remains a hard task for programmers to developer such interfaces : some knowledge of recognition systems is required, along with user experience and user interface management knowledge. It is often difficult for only one developer to handle all this knowledge by itself and it is why a team gathering different skills is most of the time needed. We previously presented a...

  14. Usability testing of the human-machine interface for the Light Duty Utility Arm System

    International Nuclear Information System (INIS)

    Kiebel, G.R.; Ellis, J.E.; Masliah, M.R.

    1994-01-01

    This report describes the usability testing that has been done for the control and data acquisition system for the Light Duty Utility Arm (LDUA) System. A program of usability testing has been established as a part of a process for making the LDUA as easy to use as possible. The LDUA System is being designed to deploy a family of tools, called End Effectors, into underground storage tanks by means of a robotic arm on the end of a telescoping mast, and to collect and manage the data that they generate. The LDUA System uses a vertical positioning mast, to lower the arm into a tank through an existing 30.5 cm access riser. A Mobile Deployment Subsystem is used to position the mast and arm over a tank riser for deployment, and to transport them from tank to tank. The LDUA System has many ancillary subsystems including the Operations Control Trailer, the Tank Riser Interface and Confinement Subsystem, the Decontamination Subsystem, and the End Effector Exchange Subsystem. This work resulted in the identification of several important improvements to the LDUA control and data acquisition system before the design was frozen. The most important of these were color coding of joints in motion, simultaneous operator control of multiple joints, and changes to the field-of-views of the camera lenses for the robot and other camera systems

  15. IEEE Std 600: IEEE trial-use standard requirements for organizations that conduct qualification testing of safety systems equipment for use in nuclear power generating stations

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    The purpose of this standard is to provide requirements for establishing a program for conducting qualification tests of safety systems equipment used in nuclear power generating stations. Compliance with the requirements of this standard does not assure the adequacy of the qualification tests performed. This standard applies to organizations that conduct qualification tests on equipment that has a definable safety function and is an identifiable part of a safety system for use in nuclear power generating stations. It requires a technical program, a quality assurance program, and a demonstrated ability to meet specified technical requirements. It does not apply to materials tests, production tests, normal performance testing, qualification by analysis, qualification by operating experience, or reliability tests such as diesel-generator multiple start tests. The intent of this standard is to achieve greater consistency, reliability, and reproducibility of test results and to provide adequate control of qualification testing of safety systems equipment

  16. Interlaboratory comparison and accreditation in quality control testing of diagnostic X-ray equipment

    International Nuclear Information System (INIS)

    Kepler, K.; Vladimirov, A.; Servomaa, A.

    2005-01-01

    The Univ. of Tartu provides a quality control service to the majority of diagnostic X-ray departments in Estonia. Its methodology has been adopted from the IEC and other relevant standards. Recently the Testing Centre of the Univ. of Tartu was accredited on this methodology by ISO/IEC 17025. Besides the implementation of the quality management system, participation in interlaboratory comparison (ILC) was one of the prerequisites for the accreditation. Tests for estimating reproducibility of tube voltage and dose rate, accuracy of the voltage and accuracy of exposure time were carried out on a diagnostic X-ray unit in the Radiation and Nuclear Safety Authority in Helsinki. The measurement performance was judged by calculating deviation En normalised with respect to the stated uncertainties. En values for all tests were less than unity and by the common ILC criteria the testing performance could be considered as acceptable. (authors)

  17. U.S. Army Natick Soldier Research, Development & Engineering Center Testing Facilities And Equipment. Second Edition

    Science.gov (United States)

    2011-04-01

    generators and cogenerators . Combustion efficiency, heat transfer, and energy balance are also determined to reconcile total energy in with total...Sand Bath .......................................... 16 Computerized Impact Testing System ............... 16 Pedar Dynamic Pressure System...33 Incline Impact Tester ...................................... 33 Environmental Chambers

  18. Revision to dedicated short range communication roadside equipment specification - RSU 4.1.Bench Test Plan.

    Science.gov (United States)

    2017-04-28

    The document describes the overall process for evaluating Dedicated Short Range Communication (DSRC) Roadside Units (RSU) against USDOT RSU Specification 4.1 in preparation for field evaluation. The Test Cases contained in this document only evaluate...

  19. 40 CFR 1068.415 - How do I test my engines/equipment?

    Science.gov (United States)

    2010-07-01

    ... POLLUTION CONTROLS GENERAL COMPLIANCE PROVISIONS FOR ENGINE PROGRAMS Selective Enforcement Auditing § 1068... for the year, you may test a minimum of one per 24-hour period. If you request and justify it, we may...

  20. Investigation with automatic ultrasonic equipment to trace flaws in a large test piece, and experience gained in carrying out inspections

    International Nuclear Information System (INIS)

    Lindner, J.P.

    1975-01-01

    Based on the FRG codes providing guide lines for the Reactor Safety Commission regarding the size and location of flaws to be detected during in-service inspections, investigations were carried out into the possibility of detecting defects in thick-walled reactor pressure vessel components with the aid of ultrasonic inspection systems. A large test rig was used and, in a similar manner to the in-service inspections on a reactor, the tests were carried out with remote-controlled, automatically guided inspection equipment. For this purpose, a test specimen weighing about 10 tons was produced and provided with two weld seams having a large number of artificial defects. Essential parameters for the various reflectors in the test specimen were the size, location, angle and roughness or structure of the reflecting surfaces. As it is known that austenitic cladding has a considerable influence on flaw detection, the tests were undertaken first without cladding and then with cladding. A manipulator was designed for automatic remote-controlled inspection with which the inspection system travels on a meandering route over the area to be inspected. The inspection system employed was of the same type as the one used for baseline tests during external inspections of reactor vessel walls with parallel surfaces. Digital data collection was by a magnetic tape recorder designed to store both the data of the ultrasonic inspection system as well as the allied position data. The data stored on the tape are evaluated with electronic data processing programmes especially developed for this purpose. These programmes allow locally coherent indication patterns to be prepared, thus simplifying the interpretation of the data obtained. The author initially describes the equipment with the aid of which the studies were undertaken. A detailed discussion is then presented on the design of the test specimen and the inspection systems employed. Following this, the results obtained are explained and

  1. Design of experiments and equipment to test the ballooning characteristics of CANDU pressure tubes

    International Nuclear Information System (INIS)

    Forrest, C.F.; Stern, F.; Hart, R.G.

    1992-01-01

    Experiments have been planned and an apparatus has been designed to enable creep testing of end-of-life pressure tube specimens in a LOCA environment. Effects that could be studied include: annealing of irradiation damage during transient heating; effects of hydride blisters on pressure tube ballooning strains; and, effects of uniformly-distributed hydrogen content on pressure tube ballooning strains. The proposed experimental program will consist of separate effects creep tests on pressure tube sections under transient heating conditions

  2. Study of the test method for prediction of air conditioning equipment seasonal performance

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, S.B.

    1980-05-01

    The test procedure, Method of Testing, Rating and Estimating the Seasonal Performance of Central Air-Conditioners and Heat Pumps Operating in the Cooling Mode, has been analyzed. The analysis of the test procedure incorporated two main functions: (1) to determine the validity of the test procedure; and (2) to determine if there are other alternate methods of obtaining the same results with less testing burden. Data were collected from industry and analyzed for any significant trends. Certain conclusions are drawn about the energy efficiency ratios, degradation coefficients and seasonal energy efficiency ratios. An error analysis was performed on the test procedure to determine the approximate amount of error when using this procedure. A semi-empirical model assuming a first order system response was developed to determine the factors that affect the part-load and cooling-load factors. The corresponding transient characteristics are then determined in terms of a single time constant. A thermostat demand cycle is used to determine the relationship between on-time and cycle-time. Recommendations are made regarding an alternate method being used to determine the seasonal energy efficiency ratio.

  3. Airside HVAC BESTEST. Adaptation of ASHRAE RP 865 Airside HVAC Equipment Modeling Test Cases for ASHRAE Standard 140. Volume 1, Cases AE101-AE445

    Energy Technology Data Exchange (ETDEWEB)

    Neymark, J. [J. Neymark & Associates, Golden, CO (United States); Kennedy, M. [Mike D. Kennedy, Inc., Townsend, WA (United States); Judkoff, R. [National Renewable Energy Lab. (NREL), Golden, CO (United States); Gall, J. [AAON, Inc., Tulsa, OK (United States); Knebel, D. [AAON, Inc., Tulsa, OK (United States); Henninger, R. [GARD Analytics, Inc., Arlington Heights, IL (United States); Witte, M. [GARD Analytics, Inc., Arlington Heights, IL (United States); Hong, T. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); McDowell, T. [Thermal Energy System Specialists, Madison, WI (United States); Yan, D. [Tsinghua Univ., Beijing (China); Zhou, X. [Tsinghua Univ., Beijing (China)

    2016-03-01

    This report documents a set of diagnostic analytical verification cases for testing the ability of whole building simulation software to model the air distribution side of typical heating, ventilating and air conditioning (HVAC) equipment. These cases complement the unitary equipment cases included in American National Standards Institute (ANSI)/American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE) Standard 140, Standard Method of Test for the Evaluation of Building Energy Analysis Computer Programs, which test the ability to model the heat-transfer fluid side of HVAC equipment.

  4. USE OF-EPR-DL FIELD TEST EQUIPMENT FOR DETECTION OF SIGMA PHASE

    Directory of Open Access Journals (Sweden)

    Abraão Danilo Gomes Barreto

    2014-06-01

    Full Text Available This work has objective to correlate the intergranular corrosion susceptibility test named EPR-DL (Electrochemical Potentiokinetic Reactivation of Double Loop with the sigma phase formation and other phases. It has been used samples from a UNS S32760 steel pipe for conducting various aging heat treatments. Held isothermal heat treatment at 850°C for 1 min, 10 min, 30 min, 1 h, 1h30min and 10 h. Each heat treated sample and as received were tested using the electrochemical polarization reactivation of double loop technique (EPR-DL. It was possible the detection of deleterious phases with DL-EPR portable cell. The EPR-DL test of some samples showed a second peak of reactivation in which the results showed that this peak might be associated with ferrite or be related to the presence of chi phase

  5. 76 FR 62961 - Lifesaving Equipment: Production Testing and Harmonization With International Standards

    Science.gov (United States)

    2011-10-11

    .... Protection of Children J. Indian Tribal Governments K. Energy Effects L. International Trade Impacts M... appropriate Coast Guard oversight ultimately promotes safety, flexibility, and autonomy by permitting experts... will accept test reports from Coast Guard-accepted independent laboratories in support of approvals for...

  6. 75 FR 71596 - Energy Efficiency Program for Certain Commercial and Industrial Equipment: Test Procedures for...

    Science.gov (United States)

    2010-11-24

    ... rulemaking because the provision within EISA which stipulates that off mode and standby mode energy usage... than night curtains made of plastic, linoleum, or other non- reflective materials. In addition, each... proposes a 6-hour test period to approximate the typical usage of a night curtain. In studies analyzing the...

  7. Development and Testing of an UltraBattery-Equipped Honda Civic Hybrid

    Energy Technology Data Exchange (ETDEWEB)

    Sally (Xiaolei) Sun; Tyler Gray; Pattie Hovorka; Jeffrey Wishart; Donald Karner; James Francfort

    2012-08-01

    The UltraBattery Retrofit Project DP1.8 and Carbon Enriched Project C3, performed by ECOtality North America (ECOtality) and funded by the U.S. Department of Energy and the Advanced Lead Acid Battery Consortium (ALABC), are established to demonstrate the suitability of advanced lead battery technology in hybrid electrical vehicles (HEVs). A profile, termed the “Simulated Honda Civic HEV Profile” (SHCHEVP) has been developed in Project DP1.8 in order to provide reproducible laboratory evaluations of different battery types under real-world HEV conditions. The cycle is based on the Urban Dynamometer Driving Schedule and Highway Fuel Economy Test cycles and simulates operation of a battery pack in a Honda Civic HEV. One pass through the SHCHEVP takes 2,140 seconds and simulates 17.7 miles of driving. A complete nickel metal hydride (NiMH) battery pack was removed from a Honda Civic HEV and operated under SHCHEVP to validate the profile. The voltage behavior and energy balance of the battery during this operation was virtually the same as that displayed by the battery when in the Honda Civic operating on the dynamometer under the Urban Dynamometer Driving Schedule and Highway Fuel Economy Test cycles, thus confirming the efficacy of the simulated profile. An important objective of the project has been to benchmark the performance of the UltraBatteries manufactured by both Furukawa Battery Co., Ltd., Japan (Furakawa) and East Penn Manufacturing Co., Inc. (East Penn). Accordingly, UltraBattery packs from both Furakawa and East Penn have been characterized under a range of conditions. Resistance measurements and capacity tests at various rates show that both battery types are very similar in performance. Both technologies, as well as a standard lead-acid module (included for baseline data), were evaluated under a simple HEV screening test. Both Furakawa and East Penn UltraBattery packs operated for over 32,000 HEV cycles, with minimal loss in performance; whereas the

  8. Inflatable Emergency Equipment I: Evaluation of Individual Inflatable Aviation Life Preserver Donning Tests

    Science.gov (United States)

    2014-12-01

    have to do so in the water. Shortly thereafter, the Survival Research Unit at CAMI devel- oped a prototype life preserver, with a primary goal of...calculate the various donning function times, as defined below. These were entered into IBM SPSS ® version 21 for statistical analysis. “TSO Test Time...inflation tubes, manual inflation triggering devices with pull tabs and CO2 cartridges, and designed to be reversible. The experimental life preserver

  9. Mirror fusion test facility cryogenic system - performance, management approach, and present equipment status

    International Nuclear Information System (INIS)

    Slack, D.S.; Chronis, W.C.

    1988-01-01

    The cryogenic system for the MFTF is a helium refrigeration system that proved to be successful and cost effective. All operating objectives were met while remaining within a few percent of the initial cost and schedule plans. The management approach used at MFTF is assessed. Manpower levels, extent and type of industrial participation, and subcontractor specifications and interactions are reviewed along with highlights of system testing, documentation, and operation

  10. Instantaneous response spectrum in seismic testing of nuclear power plant equipment

    International Nuclear Information System (INIS)

    Morrone, A.

    1977-01-01

    This paper presents the concept of instantaneous response spectrum (IRS) as the response of single degree of freedom oscillators at a particular time. It demonstrates that a shake table random motion whose standard TRS envelops the RRS does not necessarily satisfy the enveloping requirement instantaneously. That is, any one (or more) instantaneous required response spectrum (IRRS) is not enveloped by any instantaneous test response spectrum (ITRS). Response spectra from different time histories, including single frequency sine beat motion used in resonance testing, are compared for enveloping with maximum response and with the actual response at particular times. These comparisons are given for the enveloping of RRS and IRRS derived with a time history response calculated at a particular building elevation of a nuclear power plant. For the test motion, several of the most severe ITRS derived with a modified EL Centro motion and with a sine beat motion with ten cycles per beat were used. It is shown that although the TRS with the modified EL Centro motion enveloped the given RRS, the selected modified EL Centro ITRS did not envelop the corresponding IRRS. With the sine beat motion, even though the TRS did not fully envelop the given RRS, the resulting sine beat ITRS did not require a larger factor for full IRRS enveloping than those of the modified EL Centro motion

  11. Preliminary studies of tunnel interface response modeling using test data from underground storage facilities.

    Energy Technology Data Exchange (ETDEWEB)

    Sobolik, Steven Ronald; Bartel, Lewis Clark

    2010-11-01

    In attempting to detect and map out underground facilities, whether they be large-scale hardened deeply-buried targets (HDBT's) or small-scale tunnels for clandestine border or perimeter crossing, seismic imaging using reflections from the tunnel interface has been seen as one of the better ways to both detect and delineate tunnels from the surface. The large seismic impedance contrast at the tunnel/rock boundary should provide a strong, distinguishable seismic response, but in practice, such strong indicators are often lacking. One explanation for the lack of a good seismic reflection at such a strong contrast boundary is that the damage caused by the tunneling itself creates a zone of altered seismic properties that significantly changes the nature of this boundary. This report examines existing geomechanical data that define the extent of an excavation damage zone around underground tunnels, and the potential impact on rock properties such as P-wave and S-wave velocities. The data presented from this report are associated with sites used for the development of underground repositories for the disposal of radioactive waste; these sites have been excavated in volcanic tuff (Yucca Mountain) and granite (HRL in Sweden, URL in Canada). Using the data from Yucca Mountain, a numerical simulation effort was undertaken to evaluate the effects of the damage zone on seismic responses. Calculations were performed using the parallelized version of the time-domain finitedifference seismic wave propagation code developed in the Geophysics Department at Sandia National Laboratories. From these numerical simulations, the damage zone does not have a significant effect upon the tunnel response, either for a purely elastic case or an anelastic case. However, what was discovered is that the largest responses are not true reflections, but rather reradiated Stoneley waves generated as the air/earth interface of the tunnel. Because of this, data processed in the usual way may not

  12. Silicone Molding and Lifetime Testing of Peripheral Nerve Interfaces for Neuroprostheses

    Energy Technology Data Exchange (ETDEWEB)

    Gupte, Kimaya [Case Western Reserve Univ., Cleveland, OH (United States). Dept. of Biomedical Engineering; Tolosa, Vanessa [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States). Center for Micro- and Nanotechnology

    2016-08-10

    Implantable peripheral nerve cuffs have a large application in neuroprostheses as they can be used to restore sensation to those with upper limb amputations. Modern day prosthetics, while lessening the pain associated with phantom limb syndrome, have limited fine motor control and do not provide sensory feedback to patients. Sensory feedback with prosthetics requires communication between the nervous system and limbs, and is still a challenge to accomplish with amputees. Establishing this communication between the peripheral nerves in the arm and artificial limbs is vital as prosthetics research aims to provide sensory feedback to amputees. Peripheral nerve cuffs restore sensation by electrically stimulating certain parts of the nerve in order to create feeling in the hand. Cuff electrodes have an advantage over standard electrodes as they have high selective stimulation by bringing the electrical interface close to the neural tissue in order to selectively activate targeted regions of a peripheral nerve. In order to further improve the selective stimulation of these nerve cuffs, there is need for finer spatial resolution among electrodes. One method to achieve a higher spatial resolution is to increase the electrode density on the cuff itself. Microfabrication techniques can be used to achieve this higher electrode density. Using L-Edit, a layout editor, microfabricated peripheral nerve cuffs were designed with a higher electrode density than the current model. This increase in electrode density translates to an increase in spatial resolution by at least one order of magnitude. Microfabricated devices also have two separate components that are necessary to understand before implantation: lifetime of the device and assembly to prevent nerve damage. Silicone molding procedures were optimized so that devices do not damage nerves in vivo, and lifetime testing was performed on test microfabricated devices to determine their lifetime in vivo. Future work of this project

  13. German boiler and pressure vessel codes and standards: materials, manufacture, testing, equipment, erection and operation

    International Nuclear Information System (INIS)

    Steffen, H.P.

    1987-01-01

    The methods by which the safety objectives on the operation of steam boilers and pressure vessels in Germany can be reached are set out in Technical Rules which are compiled and established in technical committees. Typical applications are described in the Technical Rules. A chart shows how the laws, provisions and Technical Rules for the sections 'steam boiler plant' and 'pressure vessels' are interlinked. This chapter concentrates on legal aspects, materials, manufacture, testing, erection and operation of boilers and pressure vessels in Germany. (U.K.)

  14. Nuclear electronics equipment for control and monitoring panel. Ratemeter data and test methods

    International Nuclear Information System (INIS)

    1977-09-01

    This document first reviews the main notations used, and some definitions, then states its scope and gives a bibliography. The main characteristics of ratemeter electronic sub-assemblies are then given, and corresponding test methods are described. This type of instrument indicates, on a linear or logarithmic scale, the counting rate of pulses applied to its input. The document reviews analogue and digital ratemeters with linear or logarithmic characteristics, for general purpose applications, reactor control, health physics, plant and laboratory applications. The document is intended for electronics manufacturers, designers, persons participating in acceptance trials, plant operators and, generally, for members of the electronics profession [fr

  15. Sand and Dust Testing of Wheeled and Tracked Vehicles and Stationary Equipment

    Science.gov (United States)

    2009-11-18

    Vacuum pump Flow meter Measurement of dust mass ±2 percent ±4 percent ±0.0005 g Weight of air cleaner element ±0.5 percent (Total estimated error...samplers should be set to a flow rate that is isokinetic ) on the front of the vehicle, in the center of the grill or windshield, or the center of...3) Record the test bed vehicle odometer and hour meter reading. (4) Document the condition of the vehicle interior, exterior, and all

  16. Metrological analysis of constancy tests in conventional medical X-ray equipment

    International Nuclear Information System (INIS)

    Alvarenga, Frederico L.; Oliveira, Paulo Marcio C.; Squair, Peterson L.; Soares, Carlos M.; Silva, Teogenes A. da

    2005-01-01

    Constancy tests in x-ray diagnostic machines should follow performance requirements with the aim to verify their safety and quality and to protect workers, patients and public members that are or may be exposed to ionizing radiation risks. In the Brazilian state of Minas Gerais, from 1999 to 2004, 110 radiometric and evaluation reports of x-ray machines were issued by accredited professionals. Most of the reports did not provide the estimation of the measurement uncertainty that should be part of the results; it means that there is a lack of metrological care in such reports which may cause difficulties to get a conclusive analysis. In this work, relevant sources of uncertainties were identified and estimated for the following tests carried out in a conventional x-ray machine: high voltage accuracy and reproducibility, air kerma rate repeatability and linearity and half-value layer determination. This work gives details on the methodology and the expanded and combined uncertainty values for each measuring procedure, which may be adopted as representative values for analysis of radiometric report. (author)

  17. A unique laboratory test rig reduces the need for offshore tests to combat calcium naphthenate deposition in oilfield process equipment.

    Energy Technology Data Exchange (ETDEWEB)

    Mediaas, Heidi; Grande, Knut; Hustad, Britt-Marie; Hoevik, Kim Reidar; Kummernes, Hege; Nergaard, Bjoern; Vindstad, Jens Emil

    2006-03-15

    Producing and refining high-TAN crude oils introduces a number of challenges, among which calcium naphthenate deposition in process facilities is the most serious production issue. Until recently, the only option for studying chemicals and process parameters in order to prevent naphthenate deposition has been field tests. Statoil has now developed a small scale pilot plant where these experiments can be performed in the laboratory at Statoil's Research and Technology Center in Trondheim, Norway. The results from the pilot plant are in full agreement with the extensive naphthenate experience obtained from almost 9 years operation of the Heidrun oilfield. The design and operational procedures for this test facility are based on the recent discovery by Statoil and ConocoPhillips of the ARN acid. The ARN acid is a prerequisite for calcium naphthenate deposition. The new continuous flow pilot plant, the Naphthenate Rig, is used to develop new environmental friendly naphthenate inhibitors and to optimize process operating conditions. Since it operates on real crudes the need for field tests in qualifying new naphthenate inhibitors is reduced. To the best of our knowledge, the rig is the first of its kind in the world. (Author)

  18. Decree of the Czechoslovak Atomic Energy Commission No. 8 as of 25 June 1981 on the testing of equipment for radioactive waste transport, storage and disposal

    International Nuclear Information System (INIS)

    1995-01-01

    The Decree stipulates that manufacturers and users of equipment for radioactive waste transportation, storage and disposal are obliged to have the equipment tested. This duty concerns radioactive waste transport casks, shielding containers, etc., except for nuclear fuel transporting facilities. Authorization to act as the national testing body was granted to the Institute for Research, Production and Application of Radioisotopes. The Decree entered into force on 1 July 1981. (J.B.)

  19. Equipment, operation and some results from a hot test of the CTH actinide separation process

    International Nuclear Information System (INIS)

    Liljenzin, J.O.; Persson, G.

    1981-01-01

    The CTH actinide separation process has been tested by treating 16 l of 10 year old waste solution from PUREX reprocessing of metallic fuel. It was in general found to operate well and, in some respects, slightly better than design specifications. The extraction process removed more than 99.995% of initial alpha activity. After the sorption steps 5 Bq/l β-activity remained in solution. The modified reversed TALSPEAK process used to separate Am and Cm from the lanthanides gave an Am-Cm product with less than 0.7% of the lanthanides and vice versa. This result can probably be somewhat improved by continuous addition of lactic acid and closer pH control. (orig.)

  20. Light Duty Utility Arm interface control document plan

    International Nuclear Information System (INIS)

    Engstrom, J.W.

    1994-01-01

    This document describes the interface control documents that will be used to identify and control interface features throughout all phases of the Light Duty Utility Arm (LDUA) development and design. After the system is built, delivered and installed in the Cold Test Facility and later at the tank farm, the Interface Control Documents can be used in maintaining the configuration control process. The Interface Control Document will consist of Interface Control Drawings and a data base directly tied to the Interface Control Drawings. The data base can be used as an index to conveniently find interface information. Design drawings and other text documents that contain interface information will appear in the database. The Interface Control Drawings will be used to document and control the data and information that define the interface boundaries between systems, subsystems and equipment. Also, the interface boundaries will define the areas of responsibility for systems and subsystems. The drawing will delineate and identify all the physical and functional interfaces that required coordination to establish and maintain compatibility between the co-functioning equipment, computer software, and the tank farm facilities. An appendix contains the Engineering interface control database system riser manual

  1. Light Duty Utility Arm interface control document plan

    Energy Technology Data Exchange (ETDEWEB)

    Engstrom, J.W.

    1994-12-27

    This document describes the interface control documents that will be used to identify and control interface features throughout all phases of the Light Duty Utility Arm (LDUA) development and design. After the system is built, delivered and installed in the Cold Test Facility and later at the tank farm, the Interface Control Documents can be used in maintaining the configuration control process. The Interface Control Document will consist of Interface Control Drawings and a data base directly tied to the Interface Control Drawings. The data base can be used as an index to conveniently find interface information. Design drawings and other text documents that contain interface information will appear in the database. The Interface Control Drawings will be used to document and control the data and information that define the interface boundaries between systems, subsystems and equipment. Also, the interface boundaries will define the areas of responsibility for systems and subsystems. The drawing will delineate and identify all the physical and functional interfaces that required coordination to establish and maintain compatibility between the co-functioning equipment, computer software, and the tank farm facilities. An appendix contains the Engineering interface control database system riser manual.

  2. Simulation of ultra-long term behavior in HLW near-field by centrifugal model test. Part 1. Development of centrifugal equipment and centrifuge model test method

    International Nuclear Information System (INIS)

    Nishimoto, Soshi; Okada, Tetsuji; Sawada, Masataka

    2011-01-01

    The objective of this paper is to develop a centrifugal equipment which can continuously be run for a long time and a model test method in order to evaluate a long term behavior which is a coupled thermo-hydro-mechanical processes in the high level wastes geological disposal repository and the neighborhood (called 'near-field'). The centrifugal equipment of CRIEPI, 'CENTURY5000-THM', developed in the present study is able to run continuously up to six months. Therefore, a long term behavior in the near-field can be simulated in a short term, for instance, the behavior for 5000 equivalent years can be simulated in six months by centrifugalizing 100 G using a 1/100 size model. We carried out a test using a nylon specimen in a centrifugal force field of 30 G and confirmed the operations of CENTURY5000-THM, control and measurement for 11 days. As the results, it was able to control the stress in the pressure vessel and measure the values of strain, temperature and pressure. And, as a result of scanning the small model of near-field including the metal overpack, bentonite buffer and rock by a medical X-rays CT scanner, the internal structure of the model was able to be evaluated when the metal artifact was reduced. From these results, the evaluation for a long term behavior of a disposal repository by the method of centrifugal model test became possible. (author)

  3. WRAP TRUPACT loading systems operational test report

    International Nuclear Information System (INIS)

    DOSRAMOS, E.V.

    1999-01-01

    This Operational Test Report documents the operational testing of the TRUPACT process equipment HNF-3918, Revision 0, TRUPACT Operational Test Procedure. The test accomplished the following: Procedure validation; Facility equipment interface; Facility personnel support; and Subcontractor personnel support interface. Field changes are documented as test exceptions with resolutions. All resolutions are completed or a formal method is identified to track the resolution through to completion

  4. Tensile test and interface retention forces between wires and composites in lingual fixed retainers.

    Science.gov (United States)

    Paolone, Maria Giacinta; Kaitsas, Roberto; Obach, Patricia; Kaitsas, Vasilios; Benedicenti, Stefano; Sorrenti, Eugenio; Barberi, Fabrizio

    2015-06-01

    In daily orthodontic clinical practice retention is very important, and lingual retainers are part of this challenge. The failure of lingual retainers may be due to many factors. The aim of this study was to assess the retention forces and mechanical behavior of different types of wires matched with different kinds of composites in lingual retainers. A tensile test was performed on cylindrical composite test specimens bonded to orthodontic wires. The specimens were constructed using four different wires: a straight wire (Remanium .016×.022″ Dentaurum), two round twisted wires (Penta One .0215″ Masel, Gold Penta Twisted .0215″ Gold N'braces) and a rectangular braided wire (D-Rect .016×.022″ Ormco); and three composites: two micro-hybrids (Micro-Hybrid Enamel Plus HFO Micerium, and Micro-Hybrid SDR U Dentsply) and a micro-nano-filled composite (Micro-Nano-Filled Transbond LR 3M). The test was performed at a speed of 10mm/min on an Inström device. The wire was fixed with a clamp. The results showed that the bonding between wires and composites in lingual fixed retainers seemed to be lowest for rectangular smooth wires and increased in round twisted and rectangular twisted wires where the bonding was so strong that the maximum tension/bond strength was greater than the ultimate tensile strength of the wire. The highest values were in rectangular twisted wires. Concerning the composites, hybrid composites had the lowest interface bonding values and broke very quickly, while the nano- and micro-composites tolerated stronger forces and displayed higher bonding values. The best results were observed with the golden twisted wire and reached 21.46 MPa with the Transbond composite. With the rectangular braided wire the retention forces were so high that the Enamel Plus composite fractured when the load exceeded 154.6 N/MPa. When the same wire was combined with the Transbond LR either the wire or the composite broke when the force exceeded 240 N. The results of this

  5. POC-scale testing of an advanced fine coal dewatering equipment/technique

    Energy Technology Data Exchange (ETDEWEB)

    Groppo, J.G.; Parekh, B.K. [Univ. of Kentucky, Lexington, KY (United States); Rawls, P. [Department of Energy, Pittsburgh, PA (United States)

    1995-11-01

    Froth flotation technique is an effective and efficient process for recovering of ultra-fine (minus 74 {mu}m) clean coal. Economical dewatering of an ultra-fine clean coal product to a 20 percent level moisture will be an important step in successful implementation of the advanced cleaning processes. This project is a step in the Department of Energy`s program to show that ultra-clean coal could be effectively dewatered to 20 percent or lower moisture using either conventional or advanced dewatering techniques. As the contract title suggests, the main focus of the program is on proof-of-concept testing of a dewatering technique for a fine clean coal product. The coal industry is reluctant to use the advanced fine coal recovery technology due to the non-availability of an economical dewatering process. in fact, in a recent survey conducted by U.S. DOE and Battelle, dewatering of fine clean coal was identified as the number one priority for the coal industry. This project will attempt to demonstrate an efficient and economic fine clean coal slurry dewatering process.

  6. A spheromak ignition experiment reusing Mirror Fusion Test Facility (MFTF) equipment

    International Nuclear Information System (INIS)

    Fowler, T.K.

    1993-01-01

    Based on available experimental results and theory, a scenario is presented to achieve ohmic ignition in a spheromak by slow (∼ 10 sec.) helicity injection using power from the Mirror Fusion Test Facility (MFTF) substation. Some of the other parts needed (vacuum vessel, coils, power supplies, pumps, shielded building space) might also be obtained from MFTF or other salvage, as well as some components needed for intermediate experiments for additional verification of the concept (especially confinement scaling). The proposed ignition experiment would serve as proof-of-principle for the spheromak DT fusion reactor design published by Hagenson and Krakowski, with a nuclear island cost about ten times less than a tokamak of comparable power. Designs at even higher power density and lower cost might be possible using Christofilos' concept of a liquid lithium blanket. Since all structures would be protected from neutrons by the lithium blanket and the tritium inventory can be reduced by continuous removal from the liquid blanket, environmental and safety characteristics appear to be favorable

  7. A study on the test of efficiency of the diagnostic X-ray equipment according to their rectifications

    International Nuclear Information System (INIS)

    Seon, Jong Ryul

    1997-01-01

    For the efficient management of the diagnostic x-ray equipment, a nation-wide inspection of hospitals was performed by an inspection institute in Taejon in the first half of 1997. Among those hospitals inspected, 28 equipments(machines) which were over 500 mA were randomly selected according to their characteristics : 7 condenser type x-ray equipments, 7 three control phase of full wave rectification of type remote control x-ray equipments, 7 single phase of full wave rectification type for general radiography equipments, and 7 single phase of full wave rectification type of R/F equipments. We obtained the following results by conducting the experiment based on the efficiency of the equipments mentioned above. 1) When te equipments are analyzed, 2 out of 7 single phase of full wave rectification type of general radiography equipments(28.6%), 3 out of 7 single phase of full wave rectification type of R/F equipments(42.9%), 5 out of 7 three phase of full wave rectification type remote of control x-ray equipments(71.4%), and 4 out of 7 condenser type of x-ray equipments(57.1%) showed suitability. It proves the superiority of the three phase of full wave rectification type of remote control x-ray equipments. 2) From the overall analysis, only about 50% of the equipments(suitability of 14 out of 28) maintain the efficient management. Therefore, maintenance management of equipments is more necessary. If the efficiency of the x-ray equipment is uniformly maintained and managed to prevent the breakdown(trouble) beforehand especially through the continuous inspection of tube voltage, tube current, exposure time, and collimator, the financial loss and exposure dose to the patient, as well as the workers engaged in radiation, can be reduced for better medical service

  8. Towards a user-friendly brain-computer interface: initial tests in ALS and PLS patients.

    Science.gov (United States)

    Bai, Ou; Lin, Peter; Huang, Dandan; Fei, Ding-Yu; Floeter, Mary Kay

    2010-08-01

    Patients usually require long-term training for effective EEG-based brain-computer interface (BCI) control due to fatigue caused by the demands for focused attention during prolonged BCI operation. We intended to develop a user-friendly BCI requiring minimal training and less mental load. Testing of BCI performance was investigated in three patients with amyotrophic lateral sclerosis (ALS) and three patients with primary lateral sclerosis (PLS), who had no previous BCI experience. All patients performed binary control of cursor movement. One ALS patient and one PLS patient performed four-directional cursor control in a two-dimensional domain under a BCI paradigm associated with human natural motor behavior using motor execution and motor imagery. Subjects practiced for 5-10min and then participated in a multi-session study of either binary control or four-directional control including online BCI game over 1.5-2h in a single visit. Event-related desynchronization and event-related synchronization in the beta band were observed in all patients during the production of voluntary movement either by motor execution or motor imagery. The online binary control of cursor movement was achieved with an average accuracy about 82.1+/-8.2% with motor execution and about 80% with motor imagery, whereas offline accuracy was achieved with 91.4+/-3.4% with motor execution and 83.3+/-8.9% with motor imagery after optimization. In addition, four-directional cursor control was achieved with an accuracy of 50-60% with motor execution and motor imagery. Patients with ALS or PLS may achieve BCI control without extended training, and fatigue might be reduced during operation of a BCI associated with human natural motor behavior. The development of a user-friendly BCI will promote practical BCI applications in paralyzed patients. Copyright 2010 International Federation of Clinical Neurophysiology. All rights reserved.

  9. Guideline to good practices for control and calibration of measuring and test equipment (M ampersand TE) at DOE nuclear facilities

    International Nuclear Information System (INIS)

    1993-03-01

    The purpose of the Guideline to Good Practices for Control and Calibration of Measuring and Test Equipment (M ampersand TE) at DOE Nuclear Facilities is to provide contractor maintenance organizations with information that may be used for the development and implementation of a rigorously controlled maintenance program directed at controlling and calibrating M ampersand TE used for maintenance tasks at DOE nuclear facilities. This document is intended to be an example guideline for the implementation of DOE Order 4330.4A, Maintenance Management Program, Chapter II, Element 11. DOE contractors should not feel obligated to adopt all parts of this guide. Rather, they should use the information contained herein as a guide for developing an M ampersand TE program applicable to their facility

  10. Evaluation of ring shear testing as a characterization method for powder flow in small-scale powder processing equipment

    DEFF Research Database (Denmark)

    Søgaard, Søren Vinter; Pedersen, Troels; Allesø, Morten

    2014-01-01

    Powder flow in small-scale equipment is challenging to predict. To meet this need, the impact of consolidation during powder flow characterization, the level of consolidation existing during discharge of powders from a tablet press hopper and the uncertainty of shear and wall friction measurements...... normal stress were approximately 200Pa and 114Pa, respectively, in the critical transition from the converging to the lower vertical section of the hopper. The lower limit of consolidation for the shear and wall friction test was approximately 500Pa and 200Pa, respectively. At this consolidation level......, the wall and shear stress resolution influences the precision of the measured powder flow properties. This study highlights the need for an improved experimental setup which would be capable of measuring the flow properties of powders under very small consolidation stresses with a high shear stress...

  11. Characterization of a PET-NEMA/IEC body phantom for quality control tests of PET/CT equipment

    International Nuclear Information System (INIS)

    Oliveira, Cassio M.; Vieira, Igor F.; Lima, Fernando R.A.; Sa, Lidia V. de

    2011-01-01

    The Brazilian Sanitary Agency from Ministry of Health requires that all PET/CT equipment must undergo minimal quality control tests using manufacturer simulators. The PET-NEMA/IEC body phantom is recommended by the IEC and NEMA to perform acceptance testing and quality control in PET/CT equipment according to specific protocols. It is essential that all simulator components (spheres and body) are properly characterized in relation to their size and internal structure volumes, since they are used to calculate the overall activity concentration and the total weight. The objective of this work was characterize a PET-NEMA/IEC body phantom for the true reconstruction in computational modeling and correct analysis of experimental results. The simulator is basically composed of three structures: the body (simulating a portion of the chest), an inner cylinder (simulating the lung tissue) and a top cover in which are coupled spheres of different sizes simulating 'hot' (tumors) and cold lesions. The spheres were evaluated in terms of volume. The same evaluations were performed with the body of the simulator and the inner cylinder, beyond of analysis of their weights (filled with water) and wall thickness. The data showed that the total weight of the simulator with all its internal structures is 12.5 kg and the volume of the 'hot' and 'cold' spheres are approximately equal to those presented by the manufacturer. The inner cylinder volume showed a significant difference between the measured and the presented in the manual. The results were used for reconstruction of the simulator in computational modeling using the code GATE. (author)

  12. Microcomputer interfacing and applications

    CERN Document Server

    Mustafa, M A

    1990-01-01

    This is the applications guide to interfacing microcomputers. It offers practical non-mathematical solutions to interfacing problems in many applications including data acquisition and control. Emphasis is given to the definition of the objectives of the interface, then comparing possible solutions and producing the best interface for every situation. Dr Mustafa A Mustafa is a senior designer of control equipment and has written many technical articles and papers on the subject of computers and their application to control engineering.

  13. International Energy Agency Building Energy Simulation Test and Diagnostic Method for Heating, Ventilating, and Air-Conditioning Equipment Models (HVAC BESTEST); Volume 1: Cases E100-E200

    Energy Technology Data Exchange (ETDEWEB)

    Neymark, J.; Judkoff, R.

    2002-01-01

    This report describes the Building Energy Simulation Test for Heating, Ventilating, and Air-Conditioning Equipment Models (HVAC BESTEST) project conducted by the Tool Evaluation and Improvement International Energy Agency (IEA) Experts Group. The group was composed of experts from the Solar Heating and Cooling (SHC) Programme, Task 22, Subtask A. The current test cases, E100-E200, represent the beginning of work on mechanical equipment test cases; additional cases that would expand the current test suite have been proposed for future development.

  14. Development of sample assay system equipped with 3He Alternative Neutron Detectors (ASAS). (2) Results of ASAS measurement test

    International Nuclear Information System (INIS)

    Tanigawa, Masafumi; Mukai, Yasunobu; Kurita, Tsutomu; Makino, Risa; Nakamura, Hironobu; Tobita, Hiroshi; Ohzu, Akira; Kureta, Masatoshi; Seya, Michio

    2015-01-01

    Against the background of the serious shortage of 3 He gas, design and development of a new detector equipped ZnS/ 10 B 2 O 3 ceramic scintillation neutron detectors in JAEA, with the support of the government (the Ministry of Education, Culture, Sports, Science and Technology). The design of the alternative 3 He detector is referred from INVS (INVentory Sample assay system (HLNCC (High Level Neutron Coincidence Counter) type)) which is being used for the verification of MOX powder etc. and is named it as ASAS (Alternative Sample Assay System). In order to prove the Pu quantitative performance as an alternative technology, several measurement tests and comparison test with INVS were conducted using ASAS. In these tests, evaluation of fundamental performance (counting efficiency and die-away time) and uncertainty evaluations were implemented. As a result, although fundamental performance of ASAS was not achieved to the one of INVS, we could confirm that ASAS has almost the same Pu quantitative performance including measurement uncertainty as that of INVS. (author)

  15. A programming system for a modular, flexible multicomputer system for the automatic control of automated test equipment

    International Nuclear Information System (INIS)

    Schmidt, J.

    1984-11-01

    The hardware used is operationally directed, consisting of largely self-functioning, micro-computing modules, combined together over a parallel systembus. For communication purposes between the modules and to synchronize their activities a multi microcomputing operating system is being developed which corresponds to the specific demands of computerized process-control (handling of real-word events under real-time conditions and operation of several parallel-running subprocesses). In order to program the user-specific test cycles a programming language has to be made available which can be coordinated with the operational range of specific test equipment in terms of commands and syntax and which can also easily be learned by operators having no specialised knowledge of data processing. With this objective in mind, a structural system is developed in this work, by the aid of which application-oriented programming languages can be implemented. The adaption of the programming system to a wide spectrum of applications in automatic testing is facilitated by its modular structure. The efficiency of the system is demonstrated by means of an industrial pilot-scale implementation. (orig./HP) [de

  16. Nuclear power plants. Electrical equipment of the safety system. Qualification

    International Nuclear Information System (INIS)

    2001-01-01

    This International Standard applies to electrical parts of safety systems employed at nuclear power plants, including components and equipment of any interface whose failure could affect unfavourably properties of the safety system. The standard also applies to non-electrical safety-related interfaces. Furthermore, the standard describes the generic process of qualification certification procedures and methods of qualification testing and related documentation. (P.A.)

  17. Automatic system of tests for control equipment in combined cycle power stations; Sistema automatico de pruebas para equipos de control en centrales de ciclo combinado

    Energy Technology Data Exchange (ETDEWEB)

    Martinez M, Miguel A; Flores L, Zenon; Delgadillo V, Miguel A; Gutierrez A, Ruben [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico)

    2001-07-01

    This article deals on the Automatic System of Tests, denominated PROBADOR, used by the Gerencia de Control e Instrumentation (GCI) of the Instituto de Investigaciones Electricas (IIE)for the accomplishment of dynamic tests in laboratory, to the systems of acquisition and control developed with the electronic line SAC-IIE that are installed in the Thermoelectric Power station of Combined Cycle (CTCC) of Dos Bocas, Veracruz and Gomez Palacio, Durango, Mexico. Also the architecture, the functions that are carried out in the equipment of the System of Acquisition and control (SAC) and in the personal computer (PC) that conforms it are described, as well as the methodology used for the development of the tests. The PC constitutes Interface Man-Machine (IMM) and in the SAC equipment the simulation of the processes is made (by means of the execution of algebraic-differential equations) in the compressor, combustion chamber, gas turbine, heat recuperators, steam turbines and condenser equipment that integrate a CTCC. The equations that are used are based in the thermodynamics, flow dynamics and heat transfer; they become attached to the real process with a margin of error that is estimated in 10%. Finally, the tendencies of the PROBADOR and the technical and economic advantages are described that it has provided for the improvement in the performance of the control systems, before different situations, with no need to have the real process. [Spanish] Este articulo versa sobre el Sistema Automatico de Pruebas, denominado PROBADOR, utilizado por la Gerencia de Control e Instrumentacion (GCI) del Instituto de Investigaciones Electricas para la realizacion de pruebas dinamicas en laboratorio, a los sistemas de adquisicion y control desarrollado con la linea electronica SAC-IIE que estan instalados en las Centrales Termoelectricas de Ciclo Combinado (CTCC) de Dos Bocas, Veracruz y Gomez Palacio, Durango, Mexico. Tambien se describen la arquitectura, las funciones que se llevan

  18. A Software Prototype Development of Human System Interfaces for Human Factors Engineering Validation Tests of SMART MCR

    International Nuclear Information System (INIS)

    Lim, Jong Tae; Kang, Young Sun; Park, Byung Yul; Han, Kwan Ho; Yang, Sung Won; Oh, In Su; Kim, Myung Ju; Bae, Mun Jin; Nam, Gi Ho; Lim, Do Yeun

    2009-12-01

    This report's aim is to develop a software prototype that will be used in the partial dynamic mockup of SMART MCR(main control room). The software mainly consist of the plant a dynamic model and various operation displays that will be installed into MCR. They includes the codes such as main data processing logics like alarm reduction logic and display methods like ecological interface display and elastic tile alarm display developed by KAERI. The unit test and integrated test of them are performed according to predefined test procedure

  19. The North Carolina State University Libraries Search Experience: Usability Testing Tabbed Search Interfaces for Academic Libraries

    Science.gov (United States)

    Teague-Rector, Susan; Ballard, Angela; Pauley, Susan K.

    2011-01-01

    Creating a learnable, effective, and user-friendly library Web site hinges on providing easy access to search. Designing a search interface for academic libraries can be particularly challenging given the complexity and range of searchable library collections, such as bibliographic databases, electronic journals, and article search silos. Library…

  20. Magnet measurement interfacing to the G-64 Euro standard bus and testing G-64 modules

    International Nuclear Information System (INIS)

    Hogrefe, R.L.

    1995-01-01

    The Magnet Measurement system utilizes various modules with a G-64 Euro (Gespac) Standard Interface. All modules are designed to be software controlled, normally under the constraints of the OS-9 operating system with all data transfers to a host computer accomplished by a serial link

  1. 77 FR 9625 - Presentation of Final Conventional Conformance Test Criteria and Common Air Interface (CAI...

    Science.gov (United States)

    2012-02-17

    ... components of a land mobile radio (LMR) system. LMR systems are commonly used by emergency responders in portable handheld and mobile vehicle-mounted devices. Although formal standards are being developed, no process is currently in place to confirm that LMR equipment advertised as P25-compliant meets all aspects...

  2. Test methods for estimating the efficacy of the fast-acting disinfectant peracetic acid on surfaces of personal protective equipment.

    Science.gov (United States)

    Lemmer, K; Howaldt, S; Heinrich, R; Roder, A; Pauli, G; Dorner, B G; Pauly, D; Mielke, M; Schwebke, I; Grunow, R

    2017-11-01

    The work aimed at developing and evaluating practically relevant methods for testing of disinfectants on contaminated personal protective equipment (PPE). Carriers were prepared from PPE fabrics and contaminated with Bacillus subtilis spores. Peracetic acid (PAA) was applied as a suitable disinfectant. In method 1, the contaminated carrier was submerged in PAA solution; in method 2, the contaminated area was covered with PAA; and in method 3, PAA, preferentially combined with a surfactant, was dispersed as a thin layer. In each method, 0·5-1% PAA reduced the viability of spores by a factor of ≥6 log 10 within 3 min. The technique of the most realistic method 3 proved to be effective at low temperatures and also with a high organic load. Vaccinia virus and Adenovirus were inactivated with 0·05-0·1% PAA by up to ≥6 log 10 within 1 min. The cytotoxicity of ricin was considerably reduced by 2% PAA within 15 min of exposure. PAA/detergent mixture enabled to cover hydrophobic PPE surfaces with a thin and yet effective disinfectant layer. The test methods are objective tools for estimating the biocidal efficacy of disinfectants on hydrophobic flexible surfaces. © 2017 The Society for Applied Microbiology.

  3. Evolution of the argillite / CEM I interface at 70 C.: in situ tests and modelling results

    International Nuclear Information System (INIS)

    Lalan, P.; Dauzeres, A.; Barker, E.; De Windt, L.; Detilleux, V.; Desveaux, P.

    2015-01-01

    French radioactive waste disposal concept involves cementitious materials in a clayey host-rock. The presence of exothermic wastes in the storage cells may induce a temperature of about 70 Celsius degrees at the material interfaces. At present, experiment thermal conditions have been undertaken at about 20 C. degrees and studies at higher temperature are really scarce, especially experiments considering diffusion through the cement / clay interface. The still on-going study presented here is focusing on argillite / CEM-I interface. A one-year experiment under in situ conditions at the Tournemire experimental station (IRSN) was carried out and meanwhile, preliminary reactive transport modelling with HYTEC helped to understand the impact of a high temperature on the physico-chemical behaviour of cement / clay interface. The first results showed decalcification of cement and diffuse carbonation as well as a possible illite precipitation of clay-type phases. A C-S-H ribbon appeared at the interface between the two materials and a layer grew between the C-S-H ribbon and the cementitious material. This layer contained zeolites and behaved as a diffusive barrier. After one year of in situ interactions, the disturbance thickness was about 350 microns in CEM-I cement paste and about 100 microns in argillite. The modelling reproduced relatively well the experimentally observed processes but the extension of the disturbance is too wide and the zeolite layer is misplaced according to the experimental observations. This study highlights the lack of data at highest temperature on the reaction kinetics, diffusion coefficients but also on porosity variations. (authors)

  4. Ten years of sodium cooled steam generator tests on the C.G.V.S. Synthesis of the results obtained on these equipments and operation experiments of an industrial size test facility

    International Nuclear Information System (INIS)

    Fontaine, J.P.; Llory, M.; Quinet, J.L.

    1984-04-01

    From 1970 to 1980, Electricite de France carried out tests on four steam generators of the fast neutron reactor series on an industrial size testing equipment, the C.G.V.S. (large power testing Circuit for Steam Generators heated by Sodium). After a presentation of the testing installation, types of tests carried out and tested apparatus, a balance of lessons drawn from the circuit exploitation, and from the main results obtained on the tested equipments and on the means of calculation COPI and SICLE codes developed or adopted to simulate steam generator operation. 33 figs., 50 refs [fr

  5. Development of the electromagnetic tomography system. Field test results using existing equipment; EM tomography system no kaihatsu. Kison sochi ni yoru test sokutei kekka

    Energy Technology Data Exchange (ETDEWEB)

    Kumekawa, Y; Miura, Y; Takasugi, S [Geothermal Energy Research and Development Co. Ltd., Tokyo (Japan); Arai, E [Metal Mining Agency of Japan, Tokyo (Japan)

    1996-05-01

    With the purpose of developing an electromagnetic tomography system, an observation was carried out with existing equipment combined, and the data was analyzed. The measuring equipment consisted of existing borehole vertical magnetic field sensors as the sensor part, MT method receivers as the receiving device, and existing CSMT method transmitters as the transmitting device. The measuring was performed at the Richmond Field Station which was abundant in existing data and which had a comparatively simple resistivity structure. The borehole vertical magnetic field sensors were lowered inside the borehole, and signal sources were arranged at 10m apart on the traverse line in the direction from northeast to southwest with the borehole as the center. The analysis of the data was made with the use of EM1D by three models, namely, 10 ohm{center_dot}m homogeneous earth model, 100 ohm{center_dot}m homogeneous earth model, and horizontal 7 layer model prepared on the basis of electric logging results; and a comparative examination was made against the measured data. As a result, it was demonstrated that the test measurement agreed very well with the model from the electric logging results and that it was the data reflecting a resistivity structure. 8 refs., 6 figs.

  6. Glenn Heat Transfer Simulation and Solver Graphical User Interface: Development and Testing

    Science.gov (United States)

    Kardamis, Joseph R.

    2004-01-01

    this process with a graphical user interface (GUI) that combines the functionality of all the executables along with adding some new functionality, such as residuals graphing and boundary conditions creation. Upon my beginning here at Glenn, many parts of the GUI, which was developed in Java, were nonfunctional. There were also issues with cross-platforming, as systems in the branch were transitioning from Silicon Graphics (SGI) machines to Linux machines. My goals this summer are to finish the parts of the GUI that are not yet completed, fix parts that did not work correctly, expand the functionality to include other useful features, such as grid surface highlighting, and make the system compatible with both Linux and SGI. I will also be heavily testing the system and providing sufficient documentation on how to use the GUI, as no such documentation existed previously.

  7. Cognitive profile in elementary algebra: the PÉPITE test interface

    OpenAIRE

    Jean , Stéphanie; Delozanne , Elisabeth; Jacoboni , Pierre; Grugeon , Brigitte

    1998-01-01

    International audience; The work presented here is part of a multidisciplinary project, called the PÉPITE project. Its aim is to set up a system to diagnose student profiles starting from a multidimensional analysis grid to evaluate their competences in elementary algebra. This paper deals with the design, the making and the evaluation of an interface in Computer Based Learning Environments. In it, we present the method adopted to set up software which proposes tasks to the students and colle...

  8. Proposed limiting values for performance criteria in acceptance testing of diagnostic X-ray equipment in the Federal Republic of Germany

    International Nuclear Information System (INIS)

    Baeuml, A.

    1989-01-01

    In the Federal Republic of Germany a new X-ray ordinance came into force in 1988 containing a specific paragraph on quality assurance for all medical X-ray units stipulating acceptance tests, regular checks and supervision by medical bodies and the competent authorities. Acceptance testing is to be performed by engineers from equipment suppliers of manufacturers in new and existing installations. It is expected that the service engineers will adjust the equipment in such a way as to obtain optimal performance before measurements are made, the results of which are to be stated in a certificate describing quality status of the equipment. A working group has developed guidelines for these acceptance tests. Items to be measured are reported and proposed limiting values and their tolerances are discussed. (author)

  9. Proposed limiting values for performance criteria in acceptance testing of diagnostic X-ray equipment in the Federal Republic of Germany

    International Nuclear Information System (INIS)

    Baeuml, A.

    1989-01-01

    In the Federal Republic of Germany a new X-ray ordinance came into force in 1988 containing a specific paragraph on quality assurance for all medical X-ray units stipulating acceptance tests, regular checks and supervision by medical bodies and the competent authorities. Acceptance testing is to be performed by engineers from the equipment suppliers or manufacturers in new and also existing installations. It is expected that the service engineers will adjust the equipment in such a way as to obtain optimal performance before measurements are made, the results of which are to be stated in a certificate describing the quality status of the equipment. A working group has developed guidelines for these acceptance tests. The items to be measured are reported and the proposed limiting values and their tolerances are discussed. (author)

  10. Determination of the bonding strength in solid oxide fuel cells’interfaces by Schwickerath crack initiation test

    Czech Academy of Sciences Publication Activity Database

    Boccaccini, D. N.; Ševeček, O.; Frandsen, L. H.; Dlouhý, Ivo; Molin, S.; Charlas, B.; Hjelm, J.; Cannio, M.; Hendriksen, P. V.

    2017-01-01

    Roč. 37, č. 11 (2017), s. 3565-3578 ISSN 0955-2219 Institutional support: RVO:68081723 Keywords : Schwickerath crack-initiation test * Three-point bending test * SOFC interfaces * Metal-ceramic bond strength Subject RIV: JI - Composite Materials OBOR OECD: Composites (including laminates, reinforced plastics, cermets, combined natural and synthetic fibre fabrics Impact factor: 3.411, year: 2016 https://apps.webofknowledge.com/full_record.do?product=WOS&search_mode=GeneralSearch&qid=3&SID=S1ftxS2ACYn8QwRNK3P&page=1&doc=1

  11. Design and Realization of Universal Data Interface

    Directory of Open Access Journals (Sweden)

    Jong-Woo Kim

    2005-03-01

    Full Text Available KARI studied data interface of Space Applications for developing Space Experimental Instrument in International Space Station, designed, and manufactured the UDIS (International Sapce Station Universal Data Interface simulator according to requirements of the data interface. This paper explains the design and implementation of UDIS for space application. UDIS is the instrument which simulate to interface the data from ISS to experiment module, payload and habitation module and use the development of a experiment system in the space. This simulator will be used to the GSE (Ground Support Equipment for test of experiment system. By realization of the simulator, we ensure data interface skills for a manned-space data communication system.

  12. A novel blister test to evaluate the interface strength between nickel coating and low carbon steel substrate

    International Nuclear Information System (INIS)

    Xiao, L.H.; Su, Xu Ping.; Wang, J.H.; Zhou, Y.C.

    2009-01-01

    A novel blister test theory model was developed based on the bending theory of beams for assessing the interface strength of the nickel coating/low carbon steel substrate material system. The strain energy of the debonded nickel coating was calculated analytically and by finite element analysis, respectively. The analytic solutions agree well with the FE calculation results. Some blister tests were carried out on the WII-5 Computer Controlled Material Mechanical Properties Testing Machine, using four nickel-coated specimens type-A, -B, -C and -D which were electrodeposited on low carbon steel substrate. Here, types A, B, C and D correspond to the nickel coating thickness of 5 μm, 10 μm, 15μm and 25μm, respectively. The interface strength, evaluated by this blister test method, is 196.86 J/m 2 and 269.40 J/m 2 for type-C and -D specimens, respectively. However the tests demonstrate that the type-A and -B specimens were cut through by the spindle and no delaminations between the coating and the substrate could be found

  13. Automatic Web-Based, Radio-Network System To Monitor And Control Equipment For Investigating Gas Flux At Water - Air Interfaces

    Science.gov (United States)

    Duc, N. T.; Silverstein, S.; Wik, M.; Beckman, P.; Crill, P. M.; Bastviken, D.; Varner, R. K.

    2015-12-01

    Aquatic ecosystems are major sources of greenhouse gases (GHG). Robust measurements of natural GHG emissions are vital for evaluating regional to global carbon budgets and for assessing climate feedbacks on natural emissions to improve climate models. Diffusive and ebullitive (bubble) transport are two major pathways of gas release from surface waters. To capture the high temporal variability of these fluxes in a well-defined footprint, we designed and built an inexpensive automatic device that includes an easily mobile diffusive flux chamber and a bubble counter, all in one. Besides a function of automatically collecting gas samples for subsequent various analyses in the laboratory, this device utilizes low cost CO2 sensor (SenseAir, Sweden) and CH4 sensor (Figaro, Japan) to measure GHG fluxes. To measure the spatial variability of emissions, each of the devices is equipped with an XBee module to enable a local radio communication DigiMesh network for time synchronization and data readout at a server-controller station on the lakeshore. Software of this server-controller is operated on a low cost Raspberry Pi computer which has a 3G connection for remote monitoring - controlling functions from anywhere in the world. From field studies in Abisko, Sweden in summer 2014 and 2015, the system has resulted in measurements of GHG fluxes comparable to manual methods. In addition, the deployments have shown the advantage of a low cost automatic network system to study GHG fluxes on lakes in remote locations.

  14. Electrical equipment qualification

    International Nuclear Information System (INIS)

    Farmer, W.S.

    1983-01-01

    Electrical equipment qualification research programs being carried out by CEA, JAERI, and Sandia Laboratories are discussed. Objectives of the program are: (1) assessment of accident simulation methods for electrical equipment qualification testing; lower coarse (2) evaluation of equipment aging and accelerated aging methods; (3) determine radiation dose spectrum to electrical equipment and assess simulation methods for qualification; (4) identify inadequacies in electrical equipment qualification procedures and standards and potential failure modes; and (5) provide data for verifying and improving standards, rules and regulatory guides

  15. Design and Achievement of User Interface Automation Testing of Linux Based on Element Tree of DogTail

    Directory of Open Access Journals (Sweden)

    Yuan Wen-Chao

    2017-01-01

    Full Text Available As Linux gets more popular around the world, the advantage of the open source on software makes people do automated UI test by unified testing framework. UI software testing can guarantee the rationality of User Interface of Linux and accuracy of the UI’s widgets. In order to set free from fuzzy and repeated manual testing, and improve efficiency, this paper achieves automation testing of UI under Linux, and proposes a method to identify and test UI widgets under Linux, which is according to element tree of DogTail automaton testing framework. It achieves automation test of UI under Linux. According to this method, Aiming at the product of Red Hat Subscription Manager under Red Hat Enterprise Linux, it designs the automation test plan of this series of product’s dialogs. After many tests, it is indicated that this plan can identify UI widgets accurately and rationally, describe the structure of software clearly, avoid software errors and improve efficiency of the software. Simultaneously, it also can be used in the internationalization testing for checking translation during software internationalization.

  16. Usability testing of a respiratory interface using computer screen and facial expressions videos.

    Science.gov (United States)

    Oliveira, Ana; Pinho, Cátia; Monteiro, Sandra; Marcos, Ana; Marques, Alda

    2013-12-01

    Computer screen videos (CSVs) and users' facial expressions videos (FEVs) are recommended to evaluate systems performance. However, software combining both methods is often non-accessible in clinical research fields. The Observer-XT software is commonly used for clinical research to assess human behaviours. Thus, this study reports on the combination of CSVs and FEVs, to evaluate a graphical user interface (GUI). Eight physiotherapists entered clinical information in the GUI while CSVs and FEVs were collected. The frequency and duration of a list of behaviours found in FEVs were analysed using the Observer-XT-10.5. Simultaneously, the frequency and duration of usability problems of CSVs were manually registered. CSVs and FEVs timelines were also matched to verify combinations. The analysis of FEVs revealed that the category most frequently observed in users behaviour was the eye contact with the screen (ECS, 32±9) whilst verbal communication achieved the highest duration (14.8±6.9min). Regarding the CSVs, 64 problems, related with the interface (73%) and the user (27%), were found. In total, 135 usability problems were identified by combining both methods. The majority were reported through verbal communication (45.8%) and ECS (40.8%). "False alarms" and "misses" did not cause quantifiable reactions and the facial expressions problems were mainly related with the lack of familiarity (55.4%) felt by users when interacting with the interface. These findings encourage the use of Observer-XT-10.5 to conduct small usability sessions, as it identifies emergent groups of problems by combining methods. However, to validate final versions of systems further validation should be conducted using specialized software. © 2013 Published by Elsevier Ltd.

  17. On results of tests of thermal insulation structural fragments for in-vessel equipment and pipelines of the VG-400 plant on vibrational and acoustic loads

    International Nuclear Information System (INIS)

    Ledenko, S.A.; Andreev, V.A.; Mirenkov, A.F.; Zakharov, V.A.; Suvorov, V.E.; Prokimnov, V.V.

    1990-01-01

    Results of vibrostrength and acoustic fatigue tests of the fragments of thermal insulation for in-vessel equipment and pipelines of the VG-400 reactor are presented. The insulation structure is based on the insulation layer made of steel foil and carbon materials. Weak points in the insulation structure, namely - the welded joints of stiffening ribs - are detected in the course of testing. A conclusion is made on the possibility of vibrational test substitution for the acoustic ones

  18. Calibration voltage test of non invasive meter for radiodiagnostic on equipment of constant potential X-ray

    International Nuclear Information System (INIS)

    Ramos, Manoel M.O.; Peixoto, J. Guilherme P.; Pereira, Marco A.G.S.

    2009-01-01

    This work evaluates the utilization of the non invasive voltage meter PTW Diavolt Universal in industrial X ray equipment of constant potential. With the performed measurements, the conclusion is that conclusion is possible, once his use limits are identified

  19. Equipment considerations

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    Trace or ultratrace analyses require that the HPLC equipment used, including the detector, be optimal for such determinations. HPLC detectors are discussed at length in Chapter 4; discussion here is limited to the rest of the equipment. In general, commercial equipment is adequate for trace analysis; however, as the authors approach ultratrace analysis, it becomes very important to examine the equipment thoroughly and optimize it, where possible. For this reason they will review the equipment commonly used in HPLC and discuss the optimization steps. Detectability in HPLC is influenced by two factors (1): (a) baseline noise or other interferences that lead to errors in assigning the baseline absorbance; (b) peak width. 87 refs

  20. Electronic equipment packaging technology

    CERN Document Server

    Ginsberg, Gerald L

    1992-01-01

    The last twenty years have seen major advances in the electronics industry. Perhaps the most significant aspect of these advances has been the significant role that electronic equipment plays in almost all product markets. Even though electronic equipment is used in a broad base of applications, many future applications have yet to be conceived. This versatility of electron­ ics has been brought about primarily by the significant advances that have been made in integrated circuit technology. The electronic product user is rarely aware of the integrated circuits within the equipment. However, the user is often very aware of the size, weight, mod­ ularity, maintainability, aesthetics, and human interface features of the product. In fact, these are aspects of the products that often are instrumental in deter­ mining its success or failure in the marketplace. Optimizing these and other product features is the primary role of Electronic Equipment Packaging Technology. As the electronics industry continues to pr...

  1. Equipment for testing the indications accuracy of speedometers and altimeters existing on board aircraft and the tightness of the related pneumatic paths

    Directory of Open Access Journals (Sweden)

    Constantin PETRE

    2011-03-01

    Full Text Available The equipment is intended to testing the tightness of the catchment pneumatic system (Pitot tube, the transmission (pneumatic paths and the total and static air pressures processing (aircrafttype instruments in order to establish the main flight parameters and checking the correctness of the operation of related aircraft instruments: the altimeter and the speedometer.

  2. Indigenous Design for Automatic Testing of Tensile Strength Using Graphical User Interface

    OpenAIRE

    Ali Rafay; Junejo Faraz; Imtiaz Rafey; Shamsi Usama Sultan

    2016-01-01

    Tensile Testing is a fundamental material test to measure the tenacity and tensile strength. Tensile strength means ability to take tensile stress. This Universal Testing Machine is designed using Dual Cylinder Technique in order to comply with the maximun load (tensile force) with the reduction of minimum physical effort and minimized losses.It is to provide material testing opportunity to the students of different institutions, locally and globally, at lowest price; so that they can have a ...

  3. At the Interface between Language Testing and Second Language Acquisition: Language Ability and Context of Learning

    Science.gov (United States)

    Gu, Lin

    2014-01-01

    This study investigated the relationship between latent components of academic English language ability and test takers' study-abroad and classroom learning experiences through a structural equation modeling approach in the context of TOEFL iBT® testing. Data from the TOEFL iBT public dataset were used. The results showed that test takers'…

  4. Customer interface document for the Molten Salt Test Loop (MSTL) system.

    Energy Technology Data Exchange (ETDEWEB)

    Pettit, Kathleen; Kolb, William J.; Gill, David Dennis; Briggs, Ronald D.

    2012-03-01

    The National Solar Thermal Test Facility at Sandia National Laboratories has a unique test capability called the Molten Salt Test Loop (MSTL) system. MSTL is a test capability that allows customers and researchers to test components in flowing, molten nitrate salt. The components tested can range from materials samples, to individual components such as flex hoses, ball joints, and valves, up to full solar collecting systems such as central receiver panels, parabolic troughs, or linear Fresnel systems. MSTL provides realistic conditions similar to a portion of a concentrating solar power facility. The facility currently uses 60/40 nitrate 'solar salt' and can circulate the salt at pressure up to 600psi, temperature to 585 C, and flow rate of 400-600GPM depending on temperature. The purpose of this document is to provide a basis for customers to evaluate the applicability to their testing needs, and to provide an outline of expectations for conducting testing on MSTL. The document can serve as the basis for testing agreements including Work for Others (WFO) and Cooperative Research and Development Agreements (CRADA). While this document provides the basis for these agreements and describes some of the requirements for testing using MSTL and on the site at Sandia, the document is not sufficient by itself as a test agreement. The document, however, does provide customers with a uniform set of information to begin the test planning process.

  5. Asynchronous P300-based brain-computer interface to control a virtual environment: initial tests on end users.

    Science.gov (United States)

    Aloise, Fabio; Schettini, Francesca; Aricò, Pietro; Salinari, Serenella; Guger, Christoph; Rinsma, Johanna; Aiello, Marco; Mattia, Donatella; Cincotti, Febo

    2011-10-01

    Motor disability and/or ageing can prevent individuals from fully enjoying home facilities, thus worsening their quality of life. Advances in the field of accessible user interfaces for domotic appliances can represent a valuable way to improve the independence of these persons. An asynchronous P300-based Brain-Computer Interface (BCI) system was recently validated with the participation of healthy young volunteers for environmental control. In this study, the asynchronous P300-based BCI for the interaction with a virtual home environment was tested with the participation of potential end-users (clients of a Frisian home care organization) with limited autonomy due to ageing and/or motor disabilities. System testing revealed that the minimum number of stimulation sequences needed to achieve correct classification had a higher intra-subject variability in potential end-users with respect to what was previously observed in young controls. Here we show that the asynchronous modality performed significantly better as compared to the synchronous mode in continuously adapting its speed to the users' state. Furthermore, the asynchronous system modality confirmed its reliability in avoiding misclassifications and false positives, as previously shown in young healthy subjects. The asynchronous modality may contribute to filling the usability gap between BCI systems and traditional input devices, representing an important step towards their use in the activities of daily living.

  6. A Gaussian mixture model based adaptive classifier for fNIRS brain-computer interfaces and its testing via simulation

    Science.gov (United States)

    Li, Zheng; Jiang, Yi-han; Duan, Lian; Zhu, Chao-zhe

    2017-08-01

    Objective. Functional near infra-red spectroscopy (fNIRS) is a promising brain imaging technology for brain-computer interfaces (BCI). Future clinical uses of fNIRS will likely require operation over long time spans, during which neural activation patterns may change. However, current decoders for fNIRS signals are not designed to handle changing activation patterns. The objective of this study is to test via simulations a new adaptive decoder for fNIRS signals, the Gaussian mixture model adaptive classifier (GMMAC). Approach. GMMAC can simultaneously classify and track activation pattern changes without the need for ground-truth labels. This adaptive classifier uses computationally efficient variational Bayesian inference to label new data points and update mixture model parameters, using the previous model parameters as priors. We test GMMAC in simulations in which neural activation patterns change over time and compare to static decoders and unsupervised adaptive linear discriminant analysis classifiers. Main results. Our simulation experiments show GMMAC can accurately decode under time-varying activation patterns: shifts of activation region, expansions of activation region, and combined contractions and shifts of activation region. Furthermore, the experiments show the proposed method can track the changing shape of the activation region. Compared to prior work, GMMAC performed significantly better than the other unsupervised adaptive classifiers on a difficult activation pattern change simulation: 99% versus  brain-computer interfaces, including neurofeedback training systems, where operation over long time spans is required.

  7. IEEE Std 323-1983: IEEE standard for qualifying Class 1E equipment for nuclear power generating stations

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This standard describes the basic requirements for qualifying Class 1E equipment with interfaces that are to be used in nuclear power generating stations. The requirements presented include the principles, procedures, and methods of qualification. These qualification requirements, when met, will confirm the adequacy of the equipment design under normal, abnormal, design basis event, post design basis event, and in-service test conditions for the performance of safety function(s). The purpose of this standard is to identify requirements for the qualification of Class 1E equipment, including those interfaces whose failure could adversely affect the performance of Class 1E equipment and systems. The methods described shall be used for qualifying equipment, extending qualification, and updating qualification if the equipment is modified. Other issued IEEE standards which present qualification methods for specific equipment or components, or both, and those that deal with parts of the qualification program, may be used to supplement this standard, as applicable

  8. Functional Mobility Testing: A Novel Method to Establish Human System Interface Design Requirements

    Science.gov (United States)

    England, Scott A.; Benson, Elizabeth A.; Rajulu, Sudhakar

    2008-01-01

    Across all fields of human-system interface design it is vital to posses a sound methodology dictating the constraints on the system based on the capabilities of the human user. These limitations may be based on strength, mobility, dexterity, cognitive ability, etc. and combinations thereof. Data collected in an isolated environment to determine, for example, maximal strength or maximal range of motion would indeed be adequate for establishing not-to-exceed type design limitations, however these restraints on the system may be excessive over what is basally needed. Resources may potentially be saved by having a technique to determine the minimum measurements a system must accommodate. This paper specifically deals with the creation of a novel methodology for establishing mobility requirements for a new generation of space suit design concepts. Historically, the Space Shuttle and the International Space Station vehicle and space hardware design requirements documents such as the Man-Systems Integration Standards and International Space Station Flight Crew Integration Standard explicitly stated that the designers should strive to provide the maximum joint range of motion capabilities exhibited by a minimally clothed human subject. In the course of developing the Human-Systems Integration Requirements (HSIR) for the new space exploration initiative (Constellation), an effort was made to redefine the mobility requirements in the interest of safety and cost. Systems designed for manned space exploration can receive compounded gains from simplified designs that are both initially less expensive to produce and lighter, thereby, cheaper to launch.

  9. Development of a User Interface for the PVT SelfTest (PST)

    Data.gov (United States)

    National Aeronautics and Space Administration — The overarching goal of the project is to provide a brief, validated, zero upmass, performance test to provide astronauts with immediate feedback about cognitive...

  10. Modeling the fluid/soil interface erosion in the Hole Erosion Test

    Directory of Open Access Journals (Sweden)

    Kissi B.

    2012-07-01

    Full Text Available Soil erosion is a complex phenomenon which yields at its final stage to insidious fluid leakages under the hydraulic infrastructures known as piping and which are the main cause of their rupture. The Hole Erosion Test is commonly used to quantify the rate of piping erosion. In this work, The Hole Erosion Test is modelled by using Fluent software package. The aim is to predict the erosion rate of soil during the hole erosion test. The renormalization group theory – based k–ε turbulence model equations are used. This modelling makes it possible describing the effect of the clay concentration in flowing water on erosion. Unlike the usual one dimensional models, the proposed modelling shows that erosion is not uniform erosion along the hole length. In particular, the concentration of clay is found to increase noticeably the erosion rate.

  11. Grid Integration of PV Power based on PHIL testing using different Interface Algorithms

    DEFF Research Database (Denmark)

    Craciun, Bogdan-Ionut; Kerekes, Tamas; Sera, Dezso

    2013-01-01

    to be more active in grid support. Therefore, a better understanding and detailed analysis of the PV systems interaction with the grid is needed; hence power hardware in the loop (PHIL) testing involving PV power became an interesting subject to look into. To test PV systems for grid code (GC) compliance......Photovoltaic (PV) power among all renewable energies had the most accelerated growth rate in terms of installed capacity in recent years. Transmission System Operators (TSOs) changed their perspective about PV power and started to include it into their planning and operation, imposing PV systems...

  12. A minicomputer interface for realtime operations: an application to operant conditioning.

    Science.gov (United States)

    Mayor, S J; Wilson, J

    1975-09-01

    A PDP-12 interface was designed, constructed, and tested for realtime imput and output of binary information. Within limits this interface can be used with any peripheral device which operates in the binary mode. In addition to its generality of application the interface features include ease of expansion and low cost. A description of its design and operation is give here is terms of a typical application: the control of behavioral equipment (i.e. "Skinner Boxes") for operant conditioning.

  13. Performance and equipments upgrade of compact nuclear simulator

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jae Chang; Kwon, Kee Choon; Sim, Bong Shick; Kim, Jung Taek; Lee, Dong Young; Kim, Chang Hwoi; Park, Won Man; Song, Soon Ja; Yoo, Soon Duk; Yang, Kwang Nam

    1997-12-01

    The compact nuclear simulator (CNS) is installed in the Korea Atomic Energy Research Institute (KAERI) Nuclear Training Center in 1988. The CNS has been used for training of non-operator personnel such as NSSS design engineers, maintenance personnel, inspectors of regulatory body, etc. and for test facility of fuzzy control algorithm. The CNS was manufactured by KAERI and Studsvik (now Eurosim) joint project. The CNS mathematical modeling modeled a three loop Westinghouse Pressurizer Water Reactor (PWR), 993 MWe, mostly referred to as the Kori Unit 3 and 4 in Korea. But the main computer (Micro VAX II), a interface card between main computer and operator panel, and a graphic interface system are faced with frequent troubles by obsolescence and lack of spare parts. According to the above reasons, the CNS hardware should be replaced by state of the art equipment. It is planned to replace the main computer with HP workstation, a dedicated interface card with a PLC-based interface system, and a graphic interface system with an X-terminal based full graphics system. The software for a instructor console also will be modified text-based to Motif-based user interface. The Motif-based user interface provides more efficient and easy operation in a instructor console also will be modified text-based to Motif-based user interface. The Motif-based user interface provides more efficient and easy operation in a instructor console. (author). 124 refs., 2 tabs., 24 figs

  14. Adaptation of the Camera Link Interface for Flight-Instrument Applications

    Science.gov (United States)

    Randall, David P.; Mahoney, John C.

    2010-01-01

    COTS (commercial-off-the-shelf) hard ware using an industry-standard Camera Link interface is proposed to accomplish the task of designing, building, assembling, and testing electronics for an airborne spectrometer that would be low-cost, but sustain the required data speed and volume. The focal plane electronics were designed to support that hardware standard. Analysis was done to determine how these COTS electronics could be interfaced with space-qualified camera electronics. Interfaces available for spaceflight application do not support the industry standard Camera Link interface, but with careful design, COTS EGSE (electronics ground support equipment), including camera interfaces and camera simulators, can still be used.

  15. Standardized Laboratory Test Requirements for Hardening Equipment to Withstand Wave Impact Shock in Small High Speed Craft

    Science.gov (United States)

    2017-02-06

    axes. DRAFT NSWCCD-80-TR-2017/002 8 REFERENCES 1. Du Cane, P., The Planing Performance, Pressures , and Stresses in a High -Speed...Characterization of Individual Wave Slam Acceleration Responses for High Speed Craft, Proceedings of the 29 th American Towing Tank Conference...Methodologies for Small High -Speed Craft Structure, Equipment, Shock Isolation Seats, and Human Performance At-Sea, 10 th Symposium on High

  16. Quality assessment in in vivo NMR spectroscopy: V. Multicentre evaluation of prototype test objects and protocols for performance assessment in small bore MRS equipment

    DEFF Research Database (Denmark)

    Howe, F.A.; Canese, R; Podo, F

    1995-01-01

    This paper reports the results of multicentre studies aimed at designing, constructing, and evaluating prototype test objects for performance assessment in small-bore MRS systems, by utilizing the test protocols already proposed by the EEC COMAC-BME Concerted Action for clinical MRS equipment...... using ISIS as volume localization sequence in 31P MRS. The results suggested the interest of adopting some of these prototypes for improving the comparison of spectroscopy data obtained from different sites, for providing useful means of quality assurance in experimental MRS, and facilitating....... Three classes of test objects were considered: (1) a multicompartment test object for 31P MRS measurements performed with slice-selective sequences; (2) a two-compartment test object for volume-selection 1H MRS; and (3) two-compartment test objects for assessing the performance of experimental systems...

  17. Use of automated test equipment and open-quotes paperlessclose quotes process control to implement efficient production of SSC dipole magnets

    International Nuclear Information System (INIS)

    Tobin, T.; Fagan, R.; Mitchell, D.

    1994-01-01

    In an effort to minimize human error and maximize process control and test capabilities during Collider Dipole Magnets (CDM) production, General Dynamics is developing automated test and process control equipment; known as Test ampersand Process Control Modules (TPCM's). When used along with software designed to create open-quotes paperlessclose quotes process control documentation, the system becomes the Test ampersand Process Control System (TPCS). This system simplifies business decisions and eliminates some problems normally associated with process control documentation, while reducing human errors during CDM production. It is also designed to reduce test operator errors normally incurred during test setup and data analysis. The authors present an overview of the TPCS hardware and software being developed at General Dynamics, along with the process control techniques included in TPCS

  18. Implementation of a patient-facing genomic test report in the electronic health record using a web-application interface.

    Science.gov (United States)

    Williams, Marc S; Kern, Melissa S; Lerch, Virginia R; Billet, Jonathan; Williams, Janet L; Moore, Gregory J

    2018-05-30

    Genomic medicine is emerging into clinical care. Communication of genetic laboratory results to patients and providers is hampered by the complex technical nature of the laboratory reports. This can lead to confusion and misinterpretation of the results resulting in inappropriate care. Patients usually do not receive a copy of the report leading to further opportunities for miscommunication. To address these problems, interpretive reports were created using input from the intended end users, patients and providers. This paper describes the technical development and deployment of the first patient-facing genomic test report (PGR) within an electronic health record (EHR) ecosystem using a locally developed standards-based web-application interface. A patient-facing genomic test report with a companion provider report was configured for implementation within the EHR using a locally developed software platform, COMPASS™. COMPASS™ is designed to manage secure data exchange, as well as patient and provider access to patient reported data capture and clinical display tools. COMPASS™ is built using a Software as a Service (SaaS) approach which exposes an API that apps can interact with. An authoring tool was developed that allowed creation of patient-specific PGRs and the accompanying provider reports. These were converted to a format that allowed them to be presented in the patient portal and EHR respectively using the existing COMPASS™ interface thus allowing patients, caregivers and providers access to individual reports designed for the intended end user. The PGR as developed was shown to enhance patient and provider communication around genomic results. It is built on current standards but is designed to support integration with other tools and be compatible with emerging opportunities such as SMART on FHIR. This approach could be used to support genomic return of results as the tool is scalable and generalizable.

  19. Evaluation of sulfate reduction at experimentally induced mixing interfaces using small-scale push-pull tests in an aquifer-wetland system

    International Nuclear Information System (INIS)

    Kneeshaw, Tara A.; McGuire, Jennifer T.; Smith, Erik W.; Cozzarelli, Isabelle M.

    2007-01-01

    This paper presents small-scale push-pull tests designed to evaluate the kinetic controls on SO 4 2- reduction in situ at mixing interfaces between a wetland and aquifer impacted by landfill leachate at the Norman Landfill research site, Norman, OK. Quantifying the rates of redox reactions initiated at interfaces is of great interest because interfaces have been shown to be zones of increased biogeochemical transformations and thus may play an important role in natural attenuation. To mimic the aquifer-wetland interface and evaluate reaction rates, SO 4 2- -rich anaerobic aquifer water (∼100mg/LSO 4 2- ) was introduced into SO 4 2- -depleted wetland porewater via push-pull tests. Results showed SO 4 2- reduction was stimulated by the mixing of these waters and first-order rate coefficients were comparable to those measured in other push-pull studies. However, rate data were complex involving either multiple first-order rate coefficients or a more complex rate order. In addition, a lag phase was observed prior to SO 4 2- reduction that persisted until the mixing interface between test solution and native water was recovered, irrespective of temporal and spatial constraints. The lag phase was not eliminated by the addition of electron donor (acetate) to the injected test solution. Subsequent push-pull tests designed to elucidate the nature of the lag phase support the importance of the mixing interface in controlling terminal electron accepting processes. These data suggest redox reactions may occur rapidly at the mixing interface between injected and native waters but not in the injected bulk water mass. Under these circumstances, push-pull test data should be evaluated to ensure the apparent rate is actually a function of time and that complexities in rate data be considered

  20. Fiscal 1997 research report on the survey on public test and evaluation organizations for development of welfare equipment; 1997 nendo fukushi kiki kaihatsu ni kakawaru koteki shiken hyoka kikan chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    This research studies the construction policy of public test and evaluation systems for future development and practical use of welfare equipment, through survey on the current methods for development, practical test and evaluation of welfare equipment in countries advanced in welfare, and preparation of basic data for promoting establishment of public test and evaluation functions in Japan. Infrastructure preparation for standards and public test and evaluation organizations for developing welfare equipment is being promoted by Technical Laboratory of Bicycle Industry Promotion Association and some national organizations such as Product Evaluation Technical Center, Mechanical Engineering Laboratory, National Institute of Bioscience and Human Technology, and Living and JIS Center. However, preparation of objective and across test and evaluation systems for developing welfare equipment is still insufficient. Product Evaluation Technical Center is now approaching to evaluation and standardization of welfare equipment. Public test and evaluation organizations of the UK, Sweden and Denmark are presented. (NEDO)

  1. Evolution of the nondestructive testing equipment for neutron radiography in the framework of the programs of the Services des Piles de Saclay

    International Nuclear Information System (INIS)

    1980-10-01

    The progress made in neutron radiography testing equipment is made with respect to (a) the devices located inside reactor ponds (collimation, leak-tightness, irradiation devices, detection systems), (b) neutron radiography of active parts outside the reactor ponds (testing of fuel rods several metres long by a neutron radiography system by dry feed through), (3) neutron radiography on inactive materials (fitting an axial channel and a side channel in the Triton reactor), (4) neutron radiography on a neutron guide set up at the end of the Neutron Guide Hall associated with the Orphee reactor, i.e. 70 metres from it [fr

  2. Performance test of diamond-like carbon films for lubricating ITER blanket maintenance equipment under GPa-level high contact stress

    International Nuclear Information System (INIS)

    Takeda, Nobukazu; Kakudate, Satoshi; Nakahira, Masataka; Shibanuma, Kiyoshi

    2007-01-01

    Diamond-like carbon (DLC) coating was tested as a candidate solid lubricant for transmission gears of the maintenance equipment of the blanket of the ITER instead of an oil lubricant. The wear tests using the pin-on-disk method were performed on disks with SCM440 and SNCM420 as the base materials and coated with soft, layered, and hard DLCs. All cases satisfied the required allowable contact stress (2 GPa) and lifetime (10 4 cycles), and therefore the feasibility of the DLC coating was validated. Among the three types of DLCs, the soft DLC showed the best performance. (author)

  3. Controllable Grid Interface for Testing Ancillary Service Controls and Fault Performance of Utility-Scale Wind Power Generation: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Gevorgian, Vahan; Koralewicz, Przemyslaw; Wallen, Robb; Muljadi, Eduard

    2017-02-01

    The rapid expansion of wind power has led many transmission system operators to demand modern wind power plants to comply with strict interconnection requirements. Such requirements involve various aspects of wind power plant operation, including fault ride-through and power quality performance as well as the provision of ancillary services to enhance grid reliability. During recent years, the National Renewable Energy Laboratory (NREL) of the U.S. Department of Energy has developed a new, groundbreaking testing apparatus and methodology to test and demonstrate many existing and future advanced controls for wind generation (and other renewable generation technologies) on the multimegawatt scale and medium-voltage levels. This paper describes the capabilities and control features of NREL's 7-MVA power electronic grid simulator (also called a controllable grid interface, or CGI) that enables testing many active and reactive power control features of modern wind turbine generators -- including inertial response, primary and secondary frequency responses, and voltage regulation -- under a controlled, medium-voltage grid environment. In particular, this paper focuses on the specifics of testing the balanced and unbalanced fault ride-through characteristics of wind turbine generators under simulated strong and weak medium-voltage grid conditions. In addition, this paper provides insights on the power hardware-in-the-loop feature implemented in the CGI to emulate (in real time) the conditions that might exist in various types of electric power systems under normal operations and/or contingency scenarios. Using actual test examples and simulation results, this paper describes the value of CGI as an ultimate modeling validation tool for all types of 'grid-friendly' controls by wind generation.

  4. Glove-Enabled Computer Operations (GECO): Design and Testing of an Extravehicular Activity Glove Adapted for Human-Computer Interface

    Science.gov (United States)

    Adams, Richard J.; Olowin, Aaron; Krepkovich, Eileen; Hannaford, Blake; Lindsay, Jack I. C.; Homer, Peter; Patrie, James T.; Sands, O. Scott

    2013-01-01

    The Glove-Enabled Computer Operations (GECO) system enables an extravehicular activity (EVA) glove to be dual-purposed as a human-computer interface device. This paper describes the design and human participant testing of a right-handed GECO glove in a pressurized glove box. As part of an investigation into the usability of the GECO system for EVA data entry, twenty participants were asked to complete activities including (1) a Simon Says Games in which they attempted to duplicate random sequences of targeted finger strikes and (2) a Text Entry activity in which they used the GECO glove to enter target phrases in two different virtual keyboard modes. In a within-subjects design, both activities were performed both with and without vibrotactile feedback. Participants mean accuracies in correctly generating finger strikes with the pressurized glove were surprisingly high, both with and without the benefit of tactile feedback. Five of the subjects achieved mean accuracies exceeding 99 in both conditions. In Text Entry, tactile feedback provided a statistically significant performance benefit, quantified by characters entered per minute, as well as reduction in error rate. Secondary analyses of responses to a NASA Task Loader Index (TLX) subjective workload assessments reveal a benefit for tactile feedback in GECO glove use for data entry. This first-ever investigation of employment of a pressurized EVA glove for human-computer interface opens up a wide range of future applications, including text chat communications, manipulation of procedureschecklists, cataloguingannotating images, scientific note taking, human-robot interaction, and control of suit andor other EVA systems.

  5. Multi-Megawatt-Scale Power-Hardware-in-the-Loop Interface for Testing Ancillary Grid Services by Converter-Coupled Generation: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Koralewicz, Przemyslaw J [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Gevorgian, Vahan [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Wallen, Robert B [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2017-07-26

    Power-hardware-in-the-loop (PHIL) is a simulation tool that can support electrical systems engineers in the development and experimental validation of novel, advanced control schemes that ensure the robustness and resiliency of electrical grids that have high penetrations of low-inertia variable renewable resources. With PHIL, the impact of the device under test on a generation or distribution system can be analyzed using a real-time simulator (RTS). PHIL allows for the interconnection of the RTS with a 7 megavolt ampere (MVA) power amplifier to test multi-megawatt renewable assets available at the National Wind Technology Center (NWTC). This paper addresses issues related to the development of a PHIL interface that allows testing hardware devices at actual scale. In particular, the novel PHIL interface algorithm and high-speed digital interface, which minimize the critical loop delay, are discussed.

  6. Power Lawn Mower Assembler (agric. equip.) 6-94.352--Technical Report on Standardization of the General Aptitude Test Battery.

    Science.gov (United States)

    Manpower Administration (DOL), Washington, DC. U.S. Training and Employment Service.

    The United States Training and Employment Service General Aptitude Test Battery (GATB), first published in 1947, has been included in a continuing program of research to validate the tests against success in many different occupations. The GATB consists of 12 tests which measure nine aptitudes: General Learning Ability; Verbal Aptitude; Numerical…

  7. 40 CFR 85.2233 - Steady state test equipment calibrations, adjustments, and quality control-EPA 91.

    Science.gov (United States)

    2010-07-01

    ... continuing the test until HC levels drop below 20 ppm. (2) Automatic zero and span. The analyzer conducts an automatic zero and span check prior to each test. The span check must include the HC, CO, and CO2 channels... adjustment range of the analyzer, it must lock out from testing. (3) Low flow. The system locks out from...

  8. Melt processing and property testing of a model system of plastics contained in waste from electrical and electronic equipment.

    Science.gov (United States)

    Triantou, Marianna I; Tarantili, Petroula A; Andreopoulos, Andreas G

    2015-05-01

    In the present research, blending of polymers used in electrical and electronic equipment, i.e. acrylonitrile-butadiene-styrene terpolymer, polycarbonate and polypropylene, was performed in a twin-screw extruder, in order to explore the effect process parameters on the mixture properties, in an attempt to determine some characteristics of a fast and economical procedure for waste management. The addition of polycarbonate in acrylonitrile-butadiene-styrene terpolymer seemed to increase its thermal stability. Also, the addition of polypropylene in acrylonitrile-butadiene-styrene terpolymer facilitates its melt processing, whereas the addition of acrylonitrile-butadiene-styrene terpolymer in polypropylene improves its mechanical performance. Moreover, the upgrading of the above blends by incorporating 2 phr organically modified montmorillonite was investigated. The prepared nanocomposites exhibit greater tensile strength, elastic modulus and storage modulus, as well as higher melt viscosity, compared with the unreinforced blends. The incorporation of montmorillonite nanoplatelets in polycarbonate-rich acrylonitrile-butadiene-styrene terpolymer/polycarbonate blends turns the thermal degradation mechanism into a two-stage process. Alternatively to mechanical recycling, the energy recovery from the combustion of acrylonitrile-butadiene-styrene terpolymer/polycarbonate and acrylonitrile-butadiene-styrene terpolymer/polypropylene blends was recorded by measuring the gross calorific value. Comparing the investigated polymers, polypropylene presents the higher gross calorific value, followed by acrylonitrile-butadiene-styrene terpolymer and then polycarbonate. The above study allows a rough comparative evaluation of various methodologies for treating plastics from waste from electrical and electronic equipment. © The Author(s) 2015.

  9. Waste Isolation Pilot Plant Materials Interface Interactions Test: Papers presented at the Commission of European Communities workshop on in situ testing of radioactive waste forms and engineered barriers

    International Nuclear Information System (INIS)

    Molecke, M.A.; Sorensen, N.R.

    1993-08-01

    The three papers in this report were presented at the second international workshop to feature the Waste Isolation Pilot Plant (WIPP) Materials Interface Interactions Test (MIIT). This Workshop on In Situ Tests on Radioactive Waste Forms and Engineered Barriers was held in Corsendonk, Belgium, on October 13--16, 1992, and was sponsored by the Commission of the European Communities (CEC). The Studiecentrum voor Kernenergie/Centre D'Energie Nucleaire (SCK/CEN, Belgium), and the US Department of Energy (via Savannah River) also cosponsored this workshop. Workshop participants from Belgium, France, Germany, Sweden, and the United States gathered to discuss the status, results and overviews of the MIIT program. Nine of the twenty-five total workshop papers were presented on the status and results from the WIPP MIIT program after the five-year in situ conclusion of the program. The total number of published MIIT papers is now up to almost forty. Posttest laboratory analyses are still in progress at multiple participating laboratories. The first MIIT paper in this document, by Wicks and Molecke, provides an overview of the entire test program and focuses on the waste form samples. The second paper, by Molecke and Wicks, concentrates on technical details and repository relevant observations on the in situ conduct, sampling, and termination operations of the MIIT. The third paper, by Sorensen and Molecke, presents and summarizes the available laboratory, posttest corrosion data and results for all of the candidate waste container or overpack metal specimens included in the MIIT program

  10. Ion chamber-electrometer measurement system for radiation protection tests in X-ray equipment for interventional procedures; Sistema de medicao camara de ionizacao-eletrometro para ensaios de protecao radiologica em equipamentos de raios X para procedimentos intervencionistas

    Energy Technology Data Exchange (ETDEWEB)

    Bottaro, Marcio

    2012-07-01

    A new parallel plate ionization chamber with volume of 500 cc and an electrometer with digital interface for data acquisition, configuring an ion chamber electrometer measurement system, were developed to comply with specific requirements for compulsory radiation protection tests in interventional X-ray equipment. The ion chamber has as main characteristics: low cost, mechanical strength and response variation with beam energy of less than 5% in the 40 kV to 150 kV range. The electrometer has a high gain (5x10{sup 8} V/A) transimpedance amplifier circuit and a data acquisition and control system developed in LabVIEW Registered-Sign platform, including an integrated power supply for the ion chamber bias with adjustable DC voltage output from O to 1000 V and an air density correction system. Electric field calculations, laboratory measurements in standard beams and computational simulations of radiation interactions in chamber volume with Monte Carlo Method were employed in the elaborated methodology of the ion chamber development, which was tested and validated. It was also developed a simplified methodology for electrometer calibration that assures metrological trustworthiness of the measurement system. Tests for the system performance evaluation as environmental influence response, energy response, angular dependency, linearity and air kerma and air kerma rate dependency were performed according to international standards and requirements. Additionally, for a detailed evaluation of the developed ion chamber, simulations with various scattered radiation spectra were performed. The system was applied in leakage radiation, residual radiation and scattered radiation tests, being compared with other reference systems and validated for laboratorial test routine. (author)

  11. WIPP [Waste Isolation Pilot Plant]/SRL in situ tests: Part 2, Pictorial history of MIIT [Materials Interface Interactions Tests] and final MIIT matrices, assemblies, and sample listings

    International Nuclear Information System (INIS)

    Wicks, G.G.; Weinle, M.E.; Molecke, M.A.

    1987-01-01

    In situ testing of Savannah River Plant [SRP] waste glass is an important component in ensuring technical and public confidence in the safety and effective performance of the wasteforms. Savannah River Laboratory [SRL] is currently involved in joint programs involving field testing of SRP waste in Sweden, Belgium, and the United Kingdom. Most recently, this in situ effort has been expanded to include the first field tests to be conducted in the United States, involving burial of a variety of simulated nuclear waste systems. This new effort, called the Materials Interface Interactions Tests or MIIT, is a program jointly conducted by Sandia National Laboratory/Waste Isolation Pilot Plant [WIPP] and SRL. Over 1800 samples, supplied by the United States, France, West Germany, Belgium, Canada, Japan, and the United Kingdom, were buried approximately 650m below the earth's surface in the salt geology at WIPP, near Carlsbad, New Mexico. The MIIT program is one of the largest cooperative efforts ever undertaken in the waste management field; the data produced from these tests are designed to benefit a wide cross-section of the waste management community. An earlier document provided an overview of the WIPP MIIT program and described its place in the waste glass assessment program at Savannah River. This document represents the second in this series and its objectives include: (1) providing a pictorial history of assembly and installation of wasteforms, metals, and geologic samples in WIPP; (2) providing 'finalized and completed' sample matrices for the entire 7-part MIIT program; (3) documenting final sample assemblies by the use of schematic drawings, including each sample, its orientation, and its environment; and (4) providing a complete listing of all samples and the means for managing analyses and resulting data

  12. Equipment and Protocols for Quasi-Static and Dynamic Tests of Very-High-Strength Concrete (VHSC) and High-Strength High-Ductility Concrete (HSHDC)

    Science.gov (United States)

    2016-08-01

    Concrete (VHSC) and High-Strength High-Ductility Concrete (HSHDC) En gi ne er R es ea rc h an d D ev el op m en t Ce nt er Brett A...Very-High-Strength Concrete (VHSC) and High-Strength High-Ductility Concrete (HSHDC) Brett A. Williams, Robert D. Moser, William F. Heard, Carol F...equipment and protocols for tests of both very-high-strength concrete (VHSC) and high- strength high-ductility concrete (HSHDC) to predict blast

  13. Surface rheology and interface stability.

    Energy Technology Data Exchange (ETDEWEB)

    Yaklin, Melissa A.; Cote, Raymond O.; Moffat, Harry K.; Grillet, Anne Mary; Walker, Lynn; Koehler, Timothy P.; Reichert, Matthew D. (Carnegie Mellon University, Pittsburgh, PA); Castaneda, Jaime N.; Mondy, Lisa Ann; Brooks, Carlton, F.

    2010-11-01

    We have developed a mature laboratory at Sandia to measure interfacial rheology, using a combination of home-built, commercially available, and customized commercial tools. An Interfacial Shear Rheometer (KSV ISR-400) was modified and the software improved to increase sensitivity and reliability. Another shear rheometer, a TA Instruments AR-G2, was equipped with a du Nouey ring, bicone geometry, and a double wall ring. These interfacial attachments were compared to each other and to the ISR. The best results with the AR-G2 were obtained with the du Nouey ring. A Micro-Interfacial Rheometer (MIR) was developed in house to obtain the much higher sensitivity given by a smaller probe. However, it was found to be difficult to apply this technique for highly elastic surfaces. Interfaces also exhibit dilatational rheology when the interface changes area, such as occurs when bubbles grow or shrink. To measure this rheological response we developed a Surface Dilatational Rheometer (SDR), in which changes in surface tension with surface area are measured during the oscillation of the volume of a pendant drop or bubble. All instruments were tested with various surfactant solutions to determine the limitations of each. In addition, foaming capability and foam stability were tested and compared with the rheology data. It was found that there was no clear correlation of surface rheology with foaming/defoaming with different types of surfactants, but, within a family of surfactants, rheology could predict the foam stability. Diffusion of surfactants to the interface and the behavior of polyelectrolytes were two subjects studied with the new equipment. Finally, surface rheological terms were added to a finite element Navier-Stokes solver and preliminary testing of the code completed. Recommendations for improved implementation were given. When completed we plan to use the computations to better interpret the experimental data and account for the effects of the underlying bulk

  14. On the testing equipment and experimental techniques for the investigation of the photoviscoelastic behaviour of soft polymers

    International Nuclear Information System (INIS)

    Weber, H.

    1983-01-01

    Creep tests with uniaxial stress and pure shear have been carried out in order to determine the behaviour of soft plastics, which is governed by a non-linear material law, and to apply it to the photoelastic analysis of biaxial stress in plastic components under quasistatic and isothermal loads. The test facility is described as well as the technique applied to correct stress/creep curves for sigma=const. Results are presented for plane and tubular samples of soft PVC and an unsaturated polyester. (orig.) [de

  15. Kinetic Interface

    DEFF Research Database (Denmark)

    2009-01-01

    A kinetic interface for orientation detection in a video training system is disclosed. The interface includes a balance platform instrumented with inertial motion sensors. The interface engages a participant's sense of balance in training exercises.......A kinetic interface for orientation detection in a video training system is disclosed. The interface includes a balance platform instrumented with inertial motion sensors. The interface engages a participant's sense of balance in training exercises....

  16. Field Guide for Testing Existing Photovoltaic Systems for Ground Faults and Installing Equipment to Mitigate Fire Hazards

    Energy Technology Data Exchange (ETDEWEB)

    Brooks, William [Brooks Engineering, Vacaville, CA (United States); Basso, Thomas [National Renewable Energy Lab. (NREL), Golden, CO (United States); Coddington, Michael [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-10-01

    Ground faults and arc faults are the two most common reasons for fires in photovoltaic (PV) arrays and methods exist that can mitigate the hazards. This report provides field procedures for testing PV arrays for ground faults, and for implementing high resolution ground fault and arc fault detectors in existing and new PV system designs.

  17. Data center equipment location and monitoring system

    DEFF Research Database (Denmark)

    2011-01-01

    A data center equipment location system includes both hardware and software to provide for location, monitoring, security and identification of servers and other equipment in equipment racks. The system provides a wired alternative to the wireless RFID tag system by using electronic ID tags...... connected to each piece of equipment, each electronic ID tag connected directly by wires to a equipment rack controller on the equipment rack. The equipment rack controllers then link over a local area network to a central control computer. The central control computer provides an operator interface......, and runs a software application program that communicates with the equipment rack controllers. The software application program of the central control computer stores IDs of the equipment rack controllers and each of its connected electronic ID tags in a database.; The software application program...

  18. Nuclear electronic equipment for control and monitoring boards. Specifications and test methods of direct current period meters

    International Nuclear Information System (INIS)

    Roquefort, Henri; Chapelot; Ramard; Tardif; Tournier; Vaux

    1973-11-01

    After a few words of introduction, mention of the main notations used and the definition of certain terms, the field of application of the document is outlined and a list of references given. The main specifications of electronic 'direct current period meter' subassemblies for the monitoring, control and safety of nuclear reactors are then defined and the corresponding test methods described. The apparatus measures on a logarithmic scale the neutron fluence rate of a reactor by means of an ionisation chamber and supplies 'period' data relative to the fluence rate variation in time. The specifications and test methods are given for the different components: logarithmic amplifier, time derivative unit, threshold releases, high tension supply for ionisation chamber, auxiliary circuits and finally the complete period meter. (author) [fr

  19. Large-component handling equipment and its use

    International Nuclear Information System (INIS)

    Krieg, S.A.; Swannack, D.L.

    1983-01-01

    The Fast Flux Test Facility (FFTF) reactor systems have special requirements for component replacements during maintenance servicing. Replacement operations must address handling of equipment within shielded metal containers while maintaining an inert atmosphere to prevent reaction of sodium with air. Plant identification of a failed component results in selecting and assembling the maintenance cask and equipment transport system for transfer from the storage facility to the Reactor Containment Building (RCB). This includes a proper diameter and length cask, inert atmosphere control consoles, component lift fixture and support structure for interface with the facility area surrounding the component. This equipment is staged in modular groups in the Reactor Service Building for transfer through the equipment airlock to the containment interior. The failed component is generally prepared for replacement by installation of the special lifting fixture attachment. Assembly of the cask support structure is performed over the component position on the containment building operating floor. The cask and shroud from the reactor interface are inerted after all manual service connections and handling attachments are completed. The component is lifted from the reactor and into the cask interior through a floor valve which is then closed to isolate the component reactor port. The cask with sodium wetted component is transferred to a service/repair location, either within containment or outside, to the Maintenance Facility cleaning and repair area. The complete equipment and handling operations for replacement of a large reactor component are described

  20. Reduction of patient doses in X-ray diagnosis using quality control tests on image and equipment

    International Nuclear Information System (INIS)

    Milu, C.; Tomulescu, V.; Sorescu, Anca; Vladareanu, M.; Olteanu, B.; Enachescu, B.; Zaharia, N.; Lesaru, M.

    1997-01-01

    In the frame of a research program under the contract with the International Atomic Energy Agency (IAEA), several patient dose measurements were performed using thermoluminescent dosemeters (TLDs) before and after application of Quality Control tests and patient dose reduction methods. The paper evidenced the practical influence factors (like the need of use of high voltage technique) and possibilities for dose reduction keeping the image quality. (authors)

  1. The Effect of Specimen Size on the Results of Concrete Adiabatic Temperature Rise Test with Commercially Available Equipment

    Directory of Open Access Journals (Sweden)

    Byung Jae Lee

    2014-12-01

    Full Text Available In this study, adiabatic temperature rise tests depending on binder type and adiabatic specimen volume were performed, and the maximum adiabatic temperature rises and the reaction factors for each mix proportion were analyzed and suggested. The results indicated that the early strength low heat blended cement mixture had the lowest maximum adiabatic temperature rise (Q∞ and the ternary blended cement mixture had the lowest reaction factor (r. Also, Q and r varied depending on the adiabatic specimen volume even when the tests were conducted with a calorimeter, which satisfies the recommendations for adiabatic conditions. Test results show a correlation: the measurements from the 50 L specimens were consistently higher than those from the 6 L specimens. However, the Q∞ and r values of the 30 L specimen were similar to those of the 50 L specimen. Based on the above correlation, the adiabatic temperature rise of the 50 L specimen could be predicted using the results of the 6 L and 30 L specimens. Therefore, it is thought that this correlation can be used for on-site concrete quality control and basic research.

  2. The Effect of Specimen Size on the Results of Concrete Adiabatic Temperature Rise Test with Commercially Available Equipment.

    Science.gov (United States)

    Lee, Byung Jae; Bang, Jin Wook; Shin, Kyung Joon; Kim, Yun Yong

    2014-12-08

    In this study, adiabatic temperature rise tests depending on binder type and adiabatic specimen volume were performed, and the maximum adiabatic temperature rises and the reaction factors for each mix proportion were analyzed and suggested. The results indicated that the early strength low heat blended cement mixture had the lowest maximum adiabatic temperature rise ( Q ∞ ) and the ternary blended cement mixture had the lowest reaction factor ( r ). Also, Q and r varied depending on the adiabatic specimen volume even when the tests were conducted with a calorimeter, which satisfies the recommendations for adiabatic conditions. Test results show a correlation: the measurements from the 50 L specimens were consistently higher than those from the 6 L specimens. However, the Q ∞ and r values of the 30 L specimen were similar to those of the 50 L specimen. Based on the above correlation, the adiabatic temperature rise of the 50 L specimen could be predicted using the results of the 6 L and 30 L specimens. Therefore, it is thought that this correlation can be used for on-site concrete quality control and basic research.

  3. Characterization of a clay-rich rock through development and installation of specific hydrogeological and diffusion test equipment in deep boreholes

    Science.gov (United States)

    Delay, Jacques; Distinguin, Marc; Dewonck, Sarah

    Andra (Agence Nationale pour la Gestion des Déchets Radioactifs - National Radioactive Waste Management Agency) has developed specific tools and methodologies to evaluate and understand the main transport mechanisms of solute species in an argillaceous rock in the framework of the scientific program of the Meuse/Haute-Marne Underground Research Laboratory. This paper focuses on three specific equipments already installed in boreholes for the determination of convection and diffusion parameters in a very low permeability environment. The first one is a specific borehole completion for head and permeability measurements with an integrated wireless telemetry device. In 1995, Andra devised a probe equipped with a pressure sensor to monitor the long-term evolution of electro-magnetically transmitted pore pressures. The data gathered by this first device, and a second one installed in 2001, have shown the occurrence of overpressures in very low permeability formations. The second device is derived from the multipacker system used for monitoring the drainage of the Oxfordian limestone due to the sinking of the shaft above the Callovo-Oxfordian. It is used for obtaining from a single borehole, a pressure profile of the argillaceous formation and its encasing units. To date, the major information obtained with these two borehole equipments is the existence of a 25-35 m anomalous excess hydraulic head in the 130 m thick Callovo-Oxfordian argillaceous formation. Head values in the argillaceous rock exceed those in the overlying Oxfordian limestone by 25-35 m, and those in the underlying Dogger by over 45 m. The third equipment described in the paper, is derived from the experiment carried out at the Mont Terri rock laboratory since 1996 for the characterization of diffusion and retention processes. The system is adapted for a borehole drilled from the surface. The objectives of this experiment are as follows: Verification of the predominant role played by molecular diffusion

  4. Probabilistic methods of optimization of scheduled tests for heat equipment of safety systems of reactor at full power

    International Nuclear Information System (INIS)

    Bilej, D.V.; Fridman, N.A.; Kolykhanov, V.N.; Skalozubov, V.I.

    2004-01-01

    This article generalises the basic results of a long-term teamwork with respect to a scientific and technical substantiation of perfection of the regulations of safe operation power units with VVER. This perfection is concerning a periodicity and volumes of tests of safety systems when a reactor works at full power. The article shows that the application of the probabilistic approaches connected to minimisation of a risk criterion function is an effective methodical base for the optimisation. For certain safety systems of serial power units with VVER 1000 the results of calculated substantiations are presented

  5. [Hydrotherapy equipment].

    Science.gov (United States)

    Tsibikov, V B; Ragozin, S I; Mikheeva, L V

    1985-01-01

    A flow-chart is developed demonstrating the relation between medical and prophylactic institutions within the organizational structure of the rehabilitation system and main types of rehabilitation procedures. In order to ascertain the priority in equipping rehabilitation services with adequate hardware the special priority criterion is introduced. The highest priority is assigned to balneotherapeutic and fangotherapeutic services. Based on the operation-by-operation analysis of clinical processes related to service and performance of balneologic procedures the preliminary set of clinical devices designed for baths, basins and showers in hospitals and rehabilitation departments is defined in a generalized form.

  6. Hierarchy of on-orbit servicing interfaces

    Science.gov (United States)

    Moe, Rud V.

    1989-01-01

    A series of equipment interfaces is involved in on-orbit servicing operations. The end-to-end hierarchy of servicing interfaces is presented. The interface concepts presented include structure and handling, and formats for transfer of resources (power, data, fluids, etc.). Consequences on cost, performance, and service ability of the use of standard designs or unique designs with interface adapters are discussed. Implications of the interface designs compatibility with remote servicing using telerobotic servicers are discussed.

  7. Development of a new test for the easy characterization of the adhesion at the interface of bilayer tablets: proof-of-concept study by experimental design.

    Science.gov (United States)

    Busignies, Virginie; Mazel, Vincent; Diarra, Harona; Tchoreloff, Pierre

    2014-12-30

    Although, adhesion at the interface of bilayer tablets is critical for their design it is difficult to characterize this adhesion between layers. In view of this, a new test with an easy implementation was proposed for the characterization of the interface of bilayer tablets. This work is presented as a proof-of-concept study to investigate the reliability of this new test with regard to the effects of some critical process parameters (e.g., compaction pressure applied on each layer) and material attributes (e.g., elasticity of the layered materials) on the interfacial adhesion of bilayer tablets. This was investigated using a design of experiment approach and the results obtained were in good accordance with those obtained with other tests and thus, confirms the potential of such a method for the measurement of the interfacial adhesion of bilayer tablets. Copyright © 2014 Elsevier B.V. All rights reserved.

  8. Testing and start up of equipment in a substation; Pruebas y puesta en servicio del equipo de una subestacion

    Energy Technology Data Exchange (ETDEWEB)

    Raull-Martin, J. [Universidad Nacional Autonoma de Mexico, Mexico, D.F. (Mexico)

    2001-09-01

    The purpose of this paper is to present a summarized version of the test series required to determine out the final condition of the isolations, the continuity of the control circuits, as well as protection, measurement, sing-positing, alarms and the total substation performance. [Spanish] El proposito de este articulo es presentar en forma compacta la serie de pruebas que se requieren para determinar el estado final de los aislamientos, la continuidad de los circuitos de control, proteccion, medicion, senalizacion, alarmas, asi como el funcionamiento del conjunto de la subestacion. Se muestra una grafica K-Temperatura y de conexiones para las pruebas con megger. Se muestra un diagrama de conexiones para determinar las marcas de polaridad este tipo bushing e interruptores; asi como para el faseo de una proteccion diferencial. Se da el diagrama de faseo interno y energizado por el lado de 23 kV de una subestacion de 230 kV.

  9. Test equipment for a flywheel energy storage system using a magnetic bearing composed of superconducting coils and superconducting bulks

    International Nuclear Information System (INIS)

    Ogata, M; Matsue, H; Yamashita, T; Hasegawa, H; Nagashima, K; Maeda, T; Matsuoka, T; Mukoyama, S; Shimizu, H; Horiuchi, S

    2016-01-01

    Energy storage systems are necessary for renewable energy sources such as solar power in order to stabilize their output power, which fluctuates widely depending on the weather. Since ‘flywheel energy storage systems’ (FWSSs) do not use chemical reactions, they do not deteriorate due to charge or discharge. This is an advantage of FWSSs in applications for renewable energy plants. A conventional FWSS has capacity limitation because of the mechanical bearings used to support the flywheel. Therefore, we have designed a superconducting magnetic bearing composed of a superconducting coil stator and a superconducting bulk rotor in order to solve this problem, and have experimentally manufactured a large scale FWSS with a capacity of 100 kWh and an output power of 300 kW. The superconducting magnetic bearing can levitate 4 tons and enables the flywheel to rotate smoothly. A performance confirmation test will be started soon. An overview of the superconducting FWSS is presented in this paper. (paper)

  10. Development of Automatic Ultrasonic Testing Equipment for Pressure-Retaining Studs and Bolts in Nuclear Power Plant

    International Nuclear Information System (INIS)

    Suh, D. M.; Park, M. H.; Hong, S. S.

    1989-01-01

    Bolting degradation problems in primary coolant pressure boundary applications have become a major concern in the nuclear industry. In the bolts concerned, the failure mechanism was either corrosion wastage(loss of bolt diameter) or stress-corrosion cracking. Here the manual ultrasonic testing of RPV(Reactor Pressure Vessel) and RCP(Reactor Coolant Pump) stud has been performed. But it is difficult to detect indications because examiner can not exactly control the rotation angle and can not distinguish the indication from signals of bolt. In many cases, the critical sizes of damage depth are very small(1-2 mm order). At critical size, the crack tends to propagatecompletly through the bolt under stress, Resulting in total fracture. Automatic stud scanner for studs(bolts) was developed because the precise measurement of bolt diameter is required in this circumstance. By use of this scanner, the rotation angle of probe was exactly controlled and the exposure time of radiations was reduced

  11. Direct current linear measurement sub-assembly data and test methods. Nuclear electronic equipment for control and monitoring panel

    International Nuclear Information System (INIS)

    1977-12-01

    The M.C.H./M.E.N.T.3 document is concerned with sub-assemblies intended for measuring on a linear scale the neutron fluence rate or radiation dose rate when connected with nuclear detectors working in current. The symbols used are described. Some definitions and a bibliography are given. The main characteristics of direct current linear measurement sub-assemblies are then described together with corresponding test methods. This type of instrument indicates on a linear scale the level of a direct current applied to its input. The document reviews linear sub-assemblies for general purpose applications, difference amplifiers for monitoring, and averaging amplifiers. The document is intended for electronics manufacturers, designers, persons participating in acceptance trials and plant operators [fr

  12. The in vitro indirect cytotoxicity test and in vivo interface bioactivity evaluation of biodegradable FHA coated Mg-Zn alloys

    Energy Technology Data Exchange (ETDEWEB)

    Li Jianan [State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240 (China); Han Pei, E-mail: hanpei_cn@163.com [Orthopaedic Department of the 6th People' s Hospital, Shanghai Jiao Tong University, Shanghai 200233 (China); Ji Weiping [Orthopaedic Department of the 6th People' s Hospital, Shanghai Jiao Tong University, Shanghai 200233 (China); Song, Yang; Zhang, Shaoxiang; Chen Ying; Zhao Changli; Zhang Fan [State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240 (China); Zhang Xiaonong, E-mail: xnzhang@sjtu.edu.cn [State Key Laboratory of Metal Matrix Composites, School of Materials Science and Engineering, Shanghai Jiao Tong University, Shanghai 200240 (China); Key Laboratory of Inorganic Coating Materials, Chinese Academy of Sciences, Shanghai 200051 (China); Jiang Yao [Orthopaedic Department of the 6th People' s Hospital, Shanghai Jiao Tong University, Shanghai 200233 (China)

    2011-12-15

    A kind of biodegradable fluoridated hydroxyapatite (FHA) coating was prepared on Mg-Zn alloy to improve the interface bioactivity in bone healing via electrodeposition method. The in vitro cytotoxicity evaluation of the ions released during degradation was taken. No toxicity was shown and even higher cells' viability appeared on the 7th day compared with the normal culture case (negative control). In vivo implantation was carried out in the femoral condyle of adult New Zealand rabbits. The cross section showed by Micro-CT scan confirmed that the better interface contacts happened in the coated group after one month implantation. Also the coating left can still be normally observed by scanning electron microscope (SEM) with a little degradation. As a result, the FHA coating may be a promising candidate to enhance interface bioactivity for biodegradable Mg alloys in orthopaedics.

  13. Equipping community pharmacy workers as agents for health behaviour change: developing and testing a theory-based smoking cessation intervention.

    Science.gov (United States)

    Steed, Liz; Sohanpal, Ratna; James, Wai-Yee; Rivas, Carol; Jumbe, Sandra; Chater, Angel; Todd, Adam; Edwards, Elizabeth; Macneil, Virginia; Macfarlane, Fraser; Greenhalgh, Trisha; Griffiths, Chris; Eldridge, Sandra; Taylor, Stephanie; Walton, Robert

    2017-08-11

    To develop a complex intervention for community pharmacy staff to promote uptake of smoking cessation services and to increase quit rates. Following the Medical Research Council framework, we used a mixed-methods approach to develop, pilot and then refine the intervention. Phase I : We used information from qualitative studies in pharmacies, systematic literature reviews and the Capability, Opportunity, Motivation-Behaviour framework to inform design of the initial version of the intervention. Phase II : We then tested the acceptability of this intervention with smoking cessation advisers and assessed fidelity using actors who visited pharmacies posing as smokers, in a pilot study. Phase III : We reviewed the content and associated theory underpinning our intervention, taking account of the results of the earlier studies and a realist analysis of published literature. We then confirmed a logic model describing the intended operation of the intervention and used this model to refine the intervention and associated materials. Eight community pharmacies in three inner east London boroughs. 12 Stop Smoking Advisers. Two, 150 min, skills-based training sessions focused on communication and behaviour change skills with between session practice. The pilot study confirmed acceptability of the intervention and showed preliminary evidence of benefit; however, organisational barriers tended to limit effective operation. The pilot data and realist review pointed to additional use of Diffusion of Innovations Theory to seat the intervention in the wider organisational context. We have developed and refined an intervention to promote smoking cessation services in community pharmacies, which we now plan to evaluate in a randomised controlled trial. UKCRN ID 18446, Pilot. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. Interface strength of SiC/SiC composites with and without helium implantation using micro-indentation test

    International Nuclear Information System (INIS)

    Saito, M.; Ohtsuka, S.

    1998-01-01

    Helium implantation effects on interface strength of SiC/SiC composite were studied using the micro-indentation fiber push-out method. Helium implantation was carried out with an accelerator at about 400 K. Total amount of implanted helium was approximately 10000 appm. Increase of the fiber push-in load was observed in as-implanted specimen. After post-implantation-annealing at 1673 K for 1 h, the change of the fiber push-in load by helium implantation was not observed. Effects of helium implantation on the interface are discussed. (orig.)

  15. Seismic qualification of equipment

    International Nuclear Information System (INIS)

    Heidebrecht, A.C.; Tso, W.K.

    1983-03-01

    This report describes the results of an investigation into the seismic qualification of equipment located in CANDU nuclear power plants. It is particularly concerned with the evaluation of current seismic qualification requirements, the development of a suitable methodology for the seismic qualification of safety systems, and the evaluation of seismic qualification analysis and testing procedures

  16. Cryogenic equipment

    International Nuclear Information System (INIS)

    Leger, L.; Javellaud, J.; Caro, C.; Gilguy, R.; Testard, O.

    1966-06-01

    The cryostats presented here were built from standard parts; this makes it possible to construct a great variety of apparatus at minimum cost. The liquid nitrogen and helium reservoirs were designed so as to reduce losses to a minimum, and so as to make the cryostats as autonomous as possible. The experimental enclosure which is generally placed in the lower part of the apparatus requires a separate study in every case. Furthermore, complete assemblies such as transfer rods, isolated traps and high vacuum valves, were designed with a similar regard for the economic aspects and for the need for standardization. This equipment thus satisfies a great variety of experimental needs; it is readily adaptable and the consumptions of helium and liquid nitrogen are very low. (authors) [fr

  17. Development of methodologies for optimization of surveillance testing and maintenance of safety related equipment at NPPs. Report of a research coordination meeting. Working material

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-09-01

    This report summarizes the results of the first meeting of the Coordinated Research Programme (CRP) on Development of Methodologies for Optimization of Surveillance Testing and Maintenance of Safety Related Equipment at NPPs, held at the Agency Headquarters in Vienna, from 16 to 20 December 1996. The purpose of this Research Coordination Meeting (RCM) was that all Chief Scientific Investigators of the groups participating in the CRP presented an outline of their proposed research projects. Additionally, the participants discussed the objective, scope, work plan and information channels of the CRP in detail. Based on these presentations and discussions, the entire project plan was updated, completed and included in this report. This report represents a common agreed project work plan for the CRP. Refs, figs, tabs.

  18. Iodine and NOx behavior in the dissolver off-gas and IODOX [Iodine Oxidation] systems in the Oak Ridge National Laboratory Integrated Equipment Test facility

    International Nuclear Information System (INIS)

    Birdwell, J.F.

    1990-01-01

    This paper describes the most recent in a series of experiments evaluating the behavior of iodine and NO x in the Integrated Equipment Test (IET) Dissolver Off-Gas (DOG) System. This work was performed as part of a joint collaborative program between the US Department of Energy and the Power and Nuclear Fuel Development Corporation of Japan. The DOG system consists of two shell-and-tube heat exchangers in which water and nitric acid are removed from the dissolver off-gas by condensation, followed by a packed tower in which NO x is removed by absorption into a dilute nitric acid solution. The paper also describes the results of the operation of the Iodine Oxidation (IODOX) System. This system serves to remove iodine from the DOG system effluent by absorption into hyperazeotropic nitric acid. 7 refs., 11 figs., 10 tabs

  19. Demonstration of the iodine and NO/sub x/ removal systems in the Oak Ridge National Laboratory integrated equipment test facility

    International Nuclear Information System (INIS)

    Lewis, B.E.; Jubin, R.T.

    1987-03-01

    This report summarizes the findings from three sets of experiments on iodine and NO/sub x/ removal performance using dual downdraft condensers in the dissolver off-gas line. The initial experiments were conducted in the laboratory using glassware in proof-of-principle tests. Two additional sets of condenser experiments were conducted using equipment prototyical for a 0.5-t/d plant in the Integrated Equipment Test (IET) facility at the Oak Ridge National Laboratory. This report also describes the NO/sub x/ removal performance of a packed scrubber in the IET during the dissolution of depleted uranium oxides. The overall iodine pass-through efficiency of the condensers in the IET was high as desired. Removal efficiencies ranged from only 0.35 to 6.29%, indicating that the bulk of the iodine in the off-gas will be transferred on through the condensers to the iodox process for final disposal rather than recycled to the dissolver. The optimum operating temperature for the first condenser was in the range of 50 to 70 0 C, with the temperature of the second condenser held near 20 0 C. The NO/sub x/ removal performance of the combined dual condensers and packed scrubber resulted in effluent off-gas stream NO/sub x/ compositions of ∼0.4 to 1.0%, which are acceptable levels for the iodox process. The NO/sub x/ removal efficiency of the condensers ranged from ∼5 to 58%, but was generally around 20%. The removal efficiency of the packed tower scrubber was observed to be in the range of 40 to 60%. The NO/sub x/ removal performance of the condensers tended to complement the performance of the scrubber in that the condenser removal afficiency was high when the scrubber efficiency was low and vice versa

  20. Design and testing of Ground Penetrating Radar equipment dedicated for civil engineering applications: ongoing activities in Working Group 1 of COST Action TU1208

    Science.gov (United States)

    Pajewski, Lara; Manacorda, Guido; Persico, Raffaele

    2015-04-01

    This work aims at presenting the ongoing research activities carried out in Working Group 1 'Novel GPR instrumentation' of the COST (European COoperation in Science and Technology) Action TU1208 'Civil Engineering Applications of Ground Penetrating Radar' (www.GPRadar.eu). The principal goal of the COST Action TU1208 is to exchange and increase scientific-technical knowledge and experience of GPR techniques in civil engineering, simultaneously promoting throughout Europe the effective use of this safe and non-destructive technique in the monitoring of infrastructures and structures. Working Group 1 (WG1) of the Action focuses on the development of innovative GPR equipment dedicated for civil engineering applications. It includes three Projects. Project 1.1 is focused on the 'Design, realisation and optimisation of innovative GPR equipment for the monitoring of critical transport infrastructures and buildings, and for the sensing of underground utilities and voids.' Project 1.2 is concerned with the 'Development and definition of advanced testing, calibration and stability procedures and protocols, for GPR equipment.' Project 1.3 deals with the 'Design, modelling and optimisation of GPR antennas.' During the first year of the Action, WG1 Members coordinated between themselves to address the state of the art and open problems in the scientific fields identified by the above-mentioned Projects [1, 2]. In carrying our this work, the WG1 strongly benefited from the participation of IDS Ingegneria dei Sistemi, one of the biggest GPR manufacturers, as well as from the contribution of external experts as David J. Daniels and Erica Utsi, sharing with the Action Members their wide experience on GPR technology and methodology (First General Meeting, July 2013). The synergy with WG2 and WG4 of the Action was useful for a deep understanding of the problems, merits and limits of available GPR equipment, as well as to discuss how to quantify the reliability of GPR results. An

  1. Asynchronous P300-Based Brain-Computer Interface to Control a Virtual Environment : Initial Tests on End Users

    NARCIS (Netherlands)

    Aloise, Fabio; Schettini, Francesca; Arico, Pietro; Salinari, Serenella; Guger, Christoph; Rinsma, Johanna; Aiello, Marco; Mattia, Donatella; Cincotti, Febo

    2011-01-01

    Motor disability and/or ageing can prevent individuals from fully enjoying home facilities, thus worsening their quality of life. Advances in the field of accessible user interfaces for domotic appliances can represent a valuable way to improve the independence of these persons. An asynchronous

  2. Salapiggy: Usability Test of the Sifteo Cubes as a Game Interface for the Money Counting Game for Preschoolers

    Science.gov (United States)

    Orense, Adrian; Decena, Berlyn Anne; Feria, Rommel

    2013-01-01

    Kinesthetic learning, one of the VAK learning styles, is now also being adapted by different gaming consoles and platforms. This paper presents Salapiggy, a two-part kinesthetic educational Sifteo game that has both a tutorial on money and sorting game. It is localized in the Philippines and uses Filipino as the User Interface Language and the…

  3. Lawrence Livermore National Laboratory (LLNL) Experimental Test Site (Site 300) Salinity Evaluation and Minimization Plan for Cooling Towers and Mechanical Equipment Discharges

    Energy Technology Data Exchange (ETDEWEB)

    Daily III, W D

    2010-02-24

    This document was created to comply with the Central Valley Regional Water Quality Control Board (CVRWQCB) Waste Discharge Requirement (Order No. 98-148). This order established new requirements to assess the effect of and effort required to reduce salts in process water discharged to the subsurface. This includes the review of technical, operational, and management options available to reduce total dissolved solids (TDS) concentrations in cooling tower and mechanical equipment water discharges at Lawrence Livermore National Laboratory's (LLNL's) Experimental Test Site (Site 300) facility. It was observed that for the six cooling towers currently in operation, the total volume of groundwater used as make up water is about 27 gallons per minute and the discharge to the subsurface via percolation pits is 13 gallons per minute. The extracted groundwater has a TDS concentration of 700 mg/L. The cooling tower discharge concentrations range from 700 to 1,400 mg/L. There is also a small volume of mechanical equipment effluent being discharged to percolation pits, with a TDS range from 400 to 3,300 mg/L. The cooling towers and mechanical equipment are maintained and operated in a satisfactory manner. No major leaks were identified. Currently, there are no re-use options being employed. Several approaches known to reduce the blow down flow rate and/or TDS concentration being discharged to the percolation pits and septic systems were reviewed for technical feasibility and cost efficiency. These options range from efforts as simple as eliminating leaks to implementing advanced and innovative treatment methods. The various options considered, and their anticipated effect on water consumption, discharge volumes, and reduced concentrations are listed and compared in this report. Based on the assessment, it was recommended that there is enough variability in equipment usage, chemistry, flow rate, and discharge configurations that each discharge location at Site 300

  4. Lawrence Livermore National Laboratory (LLNL) Experimental Test Site (Site 300) Salinity Evaluation and Minimization Plan for Cooling Towers and Mechanical Equipment Discharges

    International Nuclear Information System (INIS)

    Daily, W.D. III

    2010-01-01

    This document was created to comply with the Central Valley Regional Water Quality Control Board (CVRWQCB) Waste Discharge Requirement (Order No. 98-148). This order established new requirements to assess the effect of and effort required to reduce salts in process water discharged to the subsurface. This includes the review of technical, operational, and management options available to reduce total dissolved solids (TDS) concentrations in cooling tower and mechanical equipment water discharges at Lawrence Livermore National Laboratory's (LLNL's) Experimental Test Site (Site 300) facility. It was observed that for the six cooling towers currently in operation, the total volume of groundwater used as make up water is about 27 gallons per minute and the discharge to the subsurface via percolation pits is 13 gallons per minute. The extracted groundwater has a TDS concentration of 700 mg/L. The cooling tower discharge concentrations range from 700 to 1,400 mg/L. There is also a small volume of mechanical equipment effluent being discharged to percolation pits, with a TDS range from 400 to 3,300 mg/L. The cooling towers and mechanical equipment are maintained and operated in a satisfactory manner. No major leaks were identified. Currently, there are no re-use options being employed. Several approaches known to reduce the blow down flow rate and/or TDS concentration being discharged to the percolation pits and septic systems were reviewed for technical feasibility and cost efficiency. These options range from efforts as simple as eliminating leaks to implementing advanced and innovative treatment methods. The various options considered, and their anticipated effect on water consumption, discharge volumes, and reduced concentrations are listed and compared in this report. Based on the assessment, it was recommended that there is enough variability in equipment usage, chemistry, flow rate, and discharge configurations that each discharge location at Site 300 should be

  5. High-bandwidth memory interface

    CERN Document Server

    Kim, Chulwoo; Song, Junyoung

    2014-01-01

    This book provides an overview of recent advances in memory interface design at both the architecture and circuit levels. Coverage includes signal integrity and testing, TSV interface, high-speed serial interface including equalization, ODT, pre-emphasis, wide I/O interface including crosstalk, skew cancellation, and clock generation and distribution. Trends for further bandwidth enhancement are also covered.   • Enables readers with minimal background in memory design to understand the basics of high-bandwidth memory interface design; • Presents state-of-the-art techniques for memory interface design; • Covers memory interface design at both the circuit level and system architecture level.

  6. Interface Consistency

    DEFF Research Database (Denmark)

    Staunstrup, Jørgen

    1998-01-01

    This paper proposes that Interface Consistency is an important issue for the development of modular designs. Byproviding a precise specification of component interfaces it becomes possible to check that separately developedcomponents use a common interface in a coherent matter thus avoiding a very...... significant source of design errors. Awide range of interface specifications are possible, the simplest form is a syntactical check of parameter types.However, today it is possible to do more sophisticated forms involving semantic checks....

  7. Further Validation of Simulated Dynamic Interface Testing Techniques as a Tool in the Forecasting of Air Vehicle Deck Limits

    Science.gov (United States)

    2010-01-01

    UAV Autonomy program which includes intelligent reasoning for autonomy, technologies to enhance see and avoid capabilities, object identification ...along the ship’s base recovery course (BRC). The pilot then flies toward the stern of the ship, aligning his approach path with the ship’s lineup line...quiescent point identification . CONCLUSIONS The primary goal for conducting dynamic interface analysis is to expand existing operating envelopes and

  8. Interface models

    DEFF Research Database (Denmark)

    Ravn, Anders P.; Staunstrup, Jørgen

    1994-01-01

    This paper proposes a model for specifying interfaces between concurrently executing modules of a computing system. The model does not prescribe a particular type of communication protocol and is aimed at describing interfaces between both software and hardware modules or a combination of the two....... The model describes both functional and timing properties of an interface...

  9. An approach to human-centered design of nuclear medical equipment: the system of caption of the thyroid

    International Nuclear Information System (INIS)

    Santos, Isaac J.A. Luquetti; Silva, Carlos Borges da; Santana, Marcos; Carvalho, Paulo Victor R.; Oliveira, Mauro Vitor de; Mol, Antonio Carlos Mol; Grecco, Claudio Henrique; Augusto, Silas Cordeiro

    2005-01-01

    Technology plays an important role in modern medical centers, making health care increasingly complex, relying on complex technical equipment. This technical complexity is particularly noticeable in the nuclear medicine and can increase the risks for human error. Human error has many causes such as performance shaping factors, organizational factors and user interface design. Poorly design human system interfaces of nuclear medical equipment can increase the risks for human error. If all nuclear medical equipment had been designed with good user interfaces, incidents and accidents could be reduced as well as he time required to learn how to use the equipment. Although some manufacturers of nuclear medical equipment have already integrate human factors principles in their products, there is still a need to steer the development of nuclear medical technology toward more human-centered approach. The aim of this paper is to propose a methodology that contributes to the design, development and evaluation of nuclear medical equipment and human system interface, towards a human-centered approach. This methodology includes the ergonomic approach, based on the operator activity analysis, together with human factors standards and guidelines, questionnaires and user based testing. We describe a case study in which this methodology is being applied in evaluation of the thyroid uptake system, getting essential information and data, that ill be used in development of a new system. (author)

  10. Effects of the metabotropic glutamate receptor 5 positive allosteric modulator CDPPB on rats tested with the paired associates learning task in touchscreen-equipped operant conditioning chambers.

    Science.gov (United States)

    Lins, Brittney R; Howland, John G

    2016-03-15

    Effective treatments for the cognitive symptoms of schizophrenia are critically needed. Positive allosteric modulation (PAM) of metabotropic glutamate receptor subtype 5 (mGluR5) is one strategy currently under investigation to improve these symptoms. Examining cognition using touchscreen-equipped operant chambers may increase translation between preclinical and clinical research through analogous behavioral testing paradigms in rodents and humans. We used acute CDPPB (1-30mg/kg) treatment to examine the effects of mGluR5 PAM in the touchscreen paired associates learning (PAL) task using well-trained rats with and without co-administration of acute MK-801 (0.15mg/kg). CDPPB had no consistent effects on task performance when administered alone and failed to reverse the MK-801 induced impairments at any of the examined doses. Overall, the disruptive effects of MK-801 on PAL were consistent with previous research but increasing mGluR5 signaling is not beneficial in the PAL task. Future research should test whether administration of CDPPB during PAL acquisition increases performance. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Characterization of Si3N4-Al interface after corrosion tests Caracterização da interface Si3N4-Al após testes de corrosão

    Directory of Open Access Journals (Sweden)

    C. dos Santos

    2003-12-01

    Full Text Available Silicon nitride is a covalent ceramic material of high corrosion resistance and mechanical stability at elevated temperatures. Due to these properties, its use in metallurgical processes, such as the casting of alloys, is increasing. Therefore, the characterization of the interface between Si3N4 and the casted metal is of great importance to investigate possible interactions, which might deteriorate the ceramic mould or contaminate the metal. In this work, the use of Si3N4 as crucible material for Al-casting has been studied, by investigating the corrosion attack of liquid Al at a temperature of 1150 ºC during 30 days in air. The interface was characterized by X-ray diffraction, scanning electron microscopy and energy dispersive spectroscopy. It has been found that due to superficial oxidation two oxide layers form - SiO2 on Si3N4 and Al2O3 on Al - which effectively hinder further reactions under the conditions studied, confering high corrosion resistance to the Si3N4 crucible.Nitreto de silício (Si3N4 é um material cerâmico covalente de elevada resistência à corrosão e estabilidade mecânica em temperaturas elevadas. Devido a essas propriedades, sua utilização em processos metalúrgicos, tais como em fundição de ligas metálicas, é crescente. Desta forma, a caracterização da interface entre Si3N4 e metais fundidos é de grande interesse para investigar possíveis interações as quais poderão deteriorar o material cerâmico e/ou contaminar o metal. Nesse trabalho o uso de Si3N4 como material base de cadinhos para fundição de alumínio foi estudado, pela investigação do ataque corrosivo de Al líquido a 1150 ºC durante 30 dias, ao ar. A interface foi caracterizada por difração de raios X, microscopia eletrônica de varredura e espectroscopia de energia dispersiva. É encontrado que devido à oxidação superficial dois óxidos se formam - SiO2 no Si3N4 e Al2O3 no Al - os quais evitam possíveis reações sob as condi

  12. Medical Issues: Equipment

    Science.gov (United States)

    ... Information Packets Equipment Pool Living With SMA Medical Issues Palliative Breathing Orthopedics Nutrition Equipment Daily Life At ... curesma.org > support & care > living with sma > medical issues > equipment Equipment Individuals with SMA often require a ...

  13. Semiconductor Manufacturing equipment introduction

    International Nuclear Information System (INIS)

    Im, Jong Sun

    2001-02-01

    This book deals with semiconductor manufacturing equipment. It is comprised of nine chapters, which are manufacturing process of semiconductor device, history of semiconductor manufacturing equipment, kinds and role of semiconductor manufacturing equipment, construction and method of semiconductor manufacturing equipment, introduction of various semiconductor manufacturing equipment, spots of semiconductor manufacturing, technical elements of semiconductor manufacturing equipment, road map of technology of semiconductor manufacturing equipment and semiconductor manufacturing equipment in the 21st century.

  14. The Emotiv EPOC interface paradigm in Human-Computer Interaction

    OpenAIRE

    Ancău Dorina; Roman Nicolae-Marius; Ancău Mircea

    2017-01-01

    Numerous studies have suggested the use of decoded error potentials in the brain to improve human-computer communication. Together with state-of-the-art scientific equipment, experiments have also tested instruments with more limited performance for the time being, such as Emotiv EPOC. This study presents a review of these trials and a summary of the results obtained. However, the level of these results indicates a promising prospect for using this headset as a human-computer interface for er...

  15. Demonstration of the iodine and NO/sub x/ removal systems in the Oak Ridge National Laboratory (ORNL) Integrated Equipment Test (IET) facility

    International Nuclear Information System (INIS)

    Jubin, R.T.; Lewis, B.E.

    1986-01-01

    The overall iodine removal performance of the condensers during phase-two experiments was good (i.e., very small amounts of iodine were recycled), with removal efficiency for both condensers ranging from 0.35 to 6.29%. The removal efficiency for the first condenser ranged from 0.03 to 5.78%, and the second condenser, from 0.02 to 3.42%. In all the cases studied, the overall iodine removal efficiency appeared to be smallest, with the first condenser operating near 50 0 C. While the 50 0 C operating temperature is not necessarily the optimum temperature, the data appear to indicate that the optimum is bounded by 50 and 70 0 C. Phase three of the Integrated Equipment Test dissolver off-gas (DOG) system tests verified the operation of the dual condensers and the NO/sub x/ scrubber column under a variety of operating conditions. The removal efficiencies of the condensers were higher than anticipated, generally approx.20% in these tests. The scrubber provided an NO/sub x/ effluent of approx.0.4 to 1.0% during the entire campaign, which is consistent with the acceptable NO/sub x/ levels in the off-gas to Iodox. In addition, this 0.4-to-1.0% NO/sub x/ level in the scrubber effluent confirms the BRET design decision to omit the NO/sub x/ scrubber in a system with a DOG NO/sub x/ concentration of approx.1.0%

  16. Labelling of equipment dispensers.

    Science.gov (United States)

    Gray, D C

    1993-01-01

    A new labelling system for use on medical equipment dispensers is tested. This system uses one of the objects stored in each unit of the dispenser as the 'label', by attaching it to the front of the dispenser with tape. The new system was compared to conventional written labelling by timing subjects asked to select items from two dispensers. The new system was 27% quicker than the conventional system. Images Fig. 1 PMID:8110335

  17. On-line testing of nuclear plant temperature and pressure instrumentation and other critical plant equipment. IAEA regional workshop. Working material

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-12-31

    Under European regional TC project RER/4/011, IAEA and VUJE Training centre organized a workshop on On-line Testing of Nuclear Power Plant Temperature and Pressure Instrumentation and Other Critical Plant Equipment in Trnava, Slovak Republic, from 25 to 29 May 1998. The objective of the workshop was to review the state-of-the-art in NPP instrumentation, cover typical instrumentation problems and solutions, describe technical and regulatory requirements for verifying the performance of nuclear power plant instrumentation, describe new methods developed and applied in NPPs for on-line verification and performance of instrumentation and present new techniques using existing instrumentation to identify the on-set problems in the plant electrical, mechanical and thermal hydraulic systems. Particular emphasis was placed on temperature measurements by Resistance Temperature Detectors (RTDs) and thermocouples and pressure measurements using motion-balanced and forced-balanced pressure transmitters. This proceedings includes papers presented by the invited speakers and the participants each with an abstract as wells as a summary of the Round-Table discussions Refs, figs, tabs

  18. On-line testing of nuclear plant temperature and pressure instrumentation and other critical plant equipment. IAEA regional workshop. Working material

    International Nuclear Information System (INIS)

    1998-01-01

    Under European regional TC project RER/4/011, IAEA and VUJE Training centre organized a workshop on On-line Testing of Nuclear Power Plant Temperature and Pressure Instrumentation and Other Critical Plant Equipment in Trnava, Slovak Republic, from 25 to 29 May 1998. The objective of the workshop was to review the state-of-the-art in NPP instrumentation, cover typical instrumentation problems and solutions, describe technical and regulatory requirements for verifying the performance of nuclear power plant instrumentation, describe new methods developed and applied in NPPs for on-line verification and performance of instrumentation and present new techniques using existing instrumentation to identify the on-set problems in the plant electrical, mechanical and thermal hydraulic systems. Particular emphasis was placed on temperature measurements by Resistance Temperature Detectors (RTDs) and thermocouples and pressure measurements using motion-balanced and forced-balanced pressure transmitters. This proceedings includes papers presented by the invited speakers and the participants each with an abstract as wells as a summary of the Round-Table discussions

  19. Importance of tests in nuclear facilities

    International Nuclear Information System (INIS)

    Guillemard, B.

    1985-10-01

    In nuclear facilities, safety related systems and equipments are subject, along their whole service-life, to numerous tests. This paper analyses the role of tests in the successive stages of design, construction, exploitation of a nuclear facility. It examines several aspects of test quality control: definition of needs, test planning, intrinsic quality of each test, control of interfaces (test are both the end and the starting point of many actions concerned by quality) and the application [fr

  20. Evaluation of Interface Shear Strength Properties of Geogrid Reinforced Foamed Recycled Glass Using a Large-Scale Direct Shear Testing Apparatus

    Directory of Open Access Journals (Sweden)

    Arul Arulrajah

    2015-01-01

    Full Text Available The interface shear strength properties of geogrid reinforced recycled foamed glass (FG were determined using a large-scale direct shear test (DST apparatus. Triaxial geogrid was used as a geogrid reinforcement. The geogrid increases the confinement of FG particles during shear; consequently the geogrid reinforced FG exhibits smaller vertical displacement and dilatancy ratio than FG at the same normal stress. The failure envelope of geogrid reinforced FG, at peak and critical states, coincides and yields a unique linear line possibly attributed to the crushing of FG particles and the rearrangement of crushed FG after peak shear state. The interface shear strength coefficient α is approximately constant at 0.9. This value can be used as the interface parameter for designing a reinforced embankment and mechanically stabilized earth (MSE wall when FG is used as a lightweight backfill and triaxial geogrid is used as an extensible earth reinforcement. This research will enable FG, recently assessed as suitable for lightweight backfills, to be used together with geogrids in a sustainable manner as a lightweight MSE wall. The geogrid carries tensile forces, while FG reduces bearing stresses imposed on the in situ soil. The use of geogrid reinforced FG is thus significant from engineering, economical, and environmental perspectives.

  1. Development of a general coupling interface for the fuel performance code TRANSURANUS – Tested with the reactor dynamics code DYN3D

    International Nuclear Information System (INIS)

    Holt, L.; Rohde, U.; Seidl, M.; Schubert, A.; Van Uffelen, P.; Macián-Juan, R.

    2015-01-01

    Highlights: • A general coupling interface was developed for couplings of the TRANSURANUS code. • With this new tool simplified fuel behavior models in codes can be replaced. • Applicable e.g. for several reactor types and from normal operation up to DBA. • The general coupling interface was applied to the reactor dynamics code DYN3D. • The new coupled code system DYN3D–TRANSURANUS was successfully tested for RIA. - Abstract: A general interface is presented for coupling the TRANSURANUS fuel performance code with thermal hydraulics system, sub-channel thermal hydraulics, computational fluid dynamics (CFD) or reactor dynamics codes. As first application the reactor dynamics code DYN3D was coupled at assembly level in order to describe the fuel behavior in more detail. In the coupling, DYN3D provides process time, time-dependent rod power and thermal hydraulics conditions to TRANSURANUS, which in case of the two-way coupling approach transfers parameters like fuel temperature and cladding temperature back to DYN3D. Results of the coupled code system are presented for the reactivity transient scenario, initiated by control rod ejection. More precisely, the two-way coupling approach systematically calculates higher maximum values for the node fuel enthalpy. These differences can be explained thanks to the greater detail in fuel behavior modeling. The numerical performance for DYN3D–TRANSURANUS was proved to be fast and stable. The coupled code system can therefore improve the assessment of safety criteria, at a reasonable computational cost

  2. Finite Element Method Analysis of Nanoscratch Test for the Evaluation of Interface Adhesion Strength in Cu Thin Films on Si Substrate

    Science.gov (United States)

    Sekiguchi, Atsuko; Koike, Junichi

    2008-01-01

    Mechanical processes of the nanoscratch test are investigated using a finite element analysis of Cu/Ta/SiO2/Si multilayer films. The calculated stress distribution at the moment of delamination suggests that delamination occurs in a small region of approximately 100 nm. The driving force for delamination is the stress concentration due to strain-incompatibility at the Cu/Ta interface resulting from the large plastic deformation in Cu. The degree of stress concentration is found to depend on internal variables, such as plastic deformation, residual stress, and the elastic modulus, and on the magnitude of lateral force.

  3. A software prototype development of human system interfaces for human factors engineering validation tests of SMART MCR

    International Nuclear Information System (INIS)

    Lim, Jong Tae; Han, Kwan Ho; Yang, Seung Won

    2011-02-01

    An integrated system validation test bed used for human factors engineering validation test is being developed. This study has a goal to develop a software prototype for HFE validation of SMART MCR design. To achieve these, first, some prototype specifications of the software was developed. Then software prototypes of alarm reduction logic system, Plant Protection System, ESF-CCS, Elastic Tile Alarm Indication, and EID-based HSIs were implemented as codes. Test procedures for the software prototypes were established to verify the completeness of the codes implemented. The careful software test has been done according to these test procedures, and the result were documented

  4. LabVIEW Interface for PCI-SpaceWire Interface Card

    Science.gov (United States)

    Lux, James; Loya, Frank; Bachmann, Alex

    2005-01-01

    This software provides a LabView interface to the NT drivers for the PCISpaceWire card, which is a peripheral component interface (PCI) bus interface that conforms to the IEEE-1355/ SpaceWire standard. As SpaceWire grows in popularity, the ability to use SpaceWire links within LabVIEW will be important to electronic ground support equipment vendors. In addition, there is a need for a high-level LabVIEW interface to the low-level device- driver software supplied with the card. The LabVIEW virtual instrument (VI) provides graphical interfaces to support all (1) SpaceWire link functions, including message handling and routing; (2) monitoring as a passive tap using specialized hardware; and (3) low-level access to satellite mission-control subsystem functions. The software is supplied in a zip file that contains LabVIEW VI files, which provide various functions of the PCI-SpaceWire card, as well as higher-link-level functions. The VIs are suitably named according to the matching function names in the driver manual. A number of test programs also are provided to exercise various functions.

  5. Selection of equipment for equipment qualification

    International Nuclear Information System (INIS)

    Torr, K.G.

    1989-01-01

    This report describes the methodology applied in selecting equipment in the special safety systems for equipment qualification in the CANDU 600 MW nuclear generating stations at Gentilly 2 and Point Lepreau. Included is an explanation of the selection procedure adopted and the rationale behind the criteria used in identifying the equipment. The equipment items on the list have been grouped into three priority categories as a planning aid to AECB staff for a review of the qualification status of the special safety systems

  6. Is the interface OK?

    Digital Repository Service at National Institute of Oceanography (India)

    Suresh, T.

    When a peripheral device fails, software methods can be initially resorted to before the usual hardware test procedures are used. A test program is presented here that allows various peripherals, inter-faced to a Norsk Data computer, to be tested...

  7. Organic interfaces

    NARCIS (Netherlands)

    Poelman, W.A.; Tempelman, E.

    2014-01-01

    This paper deals with the consequences for product designers resulting from the replacement of traditional interfaces by responsive materials. Part 1 presents a theoretical framework regarding a new paradigm for man-machine interfacing. Part 2 provides an analysis of the opportunities offered by new

  8. Interface Realisms

    DEFF Research Database (Denmark)

    Pold, Søren

    2005-01-01

    This article argues for seeing the interface as an important representational and aesthetic form with implications for postmodern culture and digital aesthetics. The interface emphasizes realism due in part to the desire for transparency in Human-Computer Interaction (HCI) and partly...

  9. Environmental materials and interfaces

    International Nuclear Information System (INIS)

    1991-11-01

    A workshop that explored materials and interfaces research needs relevant to national environmental concerns was conducted at Pacific Northwest Laboratory. The purposes of the workshop were to refine the scientific research directions being planned for the Materials and Interface Program in the Molecular Science Research Center (MSRC) and further define the research and user equipment to the included as part of the proposed Environmental and Molecular Science Laboratory (EMSL). Three plenary information sessions served to outline the background, objectives, and status of the MSRC and EMSL initiatives; selected specific areas with environmentally related materials; and the status of capabilities and facilities planned for the EMSL. Attention was directed to four areas where materials and interface science can have a significant impact on prevention and remediation of environmental problems: in situ detection and characterization of hazardous wastes (sensors), minimization of hazardous waste (separation membranes, ion exchange materials, catalysts), waste containment (encapsulation and barrier materials), and fundamental understanding of contaminant transport mechanisms. During all other sessions, the participants were divided into three working groups for detailed discussion and the preparation of a written report. The working groups focused on the areas of interface structure and chemistry, materials and interface stability, and materials synthesis. These recommendations and suggestions for needed research will be useful for other researchers in proposing projects and for suggesting collaborative work with MSRC researchers. 1 fig

  10. 1/12-Scale mixing interface visualization and buoyant particle release tests in support of Tank 241-SY-101 hydrogen mitigation

    Energy Technology Data Exchange (ETDEWEB)

    Eschbach, E.J.; Enderlin, C.W.

    1993-10-01

    In support of tank waste safety programs, visualization tests were performed in the 1/12-scale tank facility, using a low-viscosity simulant. The primary objective of the tests was to obtain video records of the transient jet-sludge interaction. The intent is that these videos will provide useful qualitative data for comparison with model predictions. Two tests were initially planned: mixing interface visualization (MIV) and buoyant particle release (BPR). Completion of the buoyant particle release test was set aside in order to complete additional MIV tests. Rheological measurements were made on simulant samples before testing, and the simulant was found to exhibit thixotropic behavior. Shear vane measurements were also made on an in-situ analog of the 1/12-scale tank simulant. Simulant shear strength has been observed to be time dependent. The primary objective of obtaining video records of jet-sludge interaction was satisfied, and the records yielded jet location information which may be of use in completing model comparisons. The modeling effort is not part of this task, but this report also discusses test specific instrumentation, visualization techniques, and shear vane instrumentation which would enable improved characterization of jet-sludge interaction and simulant characteristics.

  11. 1/12-Scale mixing interface visualization and buoyant particle release tests in support of Tank 241-SY-101 hydrogen mitigation

    International Nuclear Information System (INIS)

    Eschbach, E.J.; Enderlin, C.W.

    1993-10-01

    In support of tank waste safety programs, visualization tests were performed in the 1/12-scale tank facility, using a low-viscosity simulant. The primary objective of the tests was to obtain video records of the transient jet-sludge interaction. The intent is that these videos will provide useful qualitative data for comparison with model predictions. Two tests were initially planned: mixing interface visualization (MIV) and buoyant particle release (BPR). Completion of the buoyant particle release test was set aside in order to complete additional MIV tests. Rheological measurements were made on simulant samples before testing, and the simulant was found to exhibit thixotropic behavior. Shear vane measurements were also made on an in-situ analog of the 1/12-scale tank simulant. Simulant shear strength has been observed to be time dependent. The primary objective of obtaining video records of jet-sludge interaction was satisfied, and the records yielded jet location information which may be of use in completing model comparisons. The modeling effort is not part of this task, but this report also discusses test specific instrumentation, visualization techniques, and shear vane instrumentation which would enable improved characterization of jet-sludge interaction and simulant characteristics

  12. Development of a system for monitoring and diagnosis using Fuzzy logic in control valves of laboratory test equipment of Experimental Center Aramar

    International Nuclear Information System (INIS)

    Porto Junior, Almir Carlos Soares

    2014-01-01

    The question of components reliability, specifically process control valves, has become an important issue to be investigated in nuclear power plants and other areas such as refinery or offshore oil rig, considering the safety and life extension of the plant. The development of non intrusive monitoring and diagnostic method allows the identification of defects in components of the plant during normal operation. The objective of this dissertation is to present an analysis and diagnosis of control valves of a steam plant part that simulates the secondary circuit of a pressurized water reactor. This installation is part of propulsion equipment testing laboratory of the Brazilian Navy, at Ipero-SP. The methodology for design is based on graphical analysis of two parameters, the valve air pressure actuator and the displacement of the valve plug. These data are extracted by a smart positioner, part of Delta V™ Automation System. An analysis is implemented in detecting anomalies by an approach using Expert Systems by the technique of fuzzy logic. Once the basic measures of control valves are taken, it is possible to detect symptoms of failure, leakage, friction, damage, etc. The monitoring and diagnostic system has been designed in MATLAB® version 2009 th by the complement 'Fuzzy Logic Toolbox'. It is a noninvasive technique. Thus, it is possible to know what is happening with the chosen components, just analyzing the parameters of the valve. The software called ValveLink® (developed by Emerson) receives signals from hardware component (intelligent positioner) installed next to the control valve. These signals (electrical current) are transformed into information which are used input parameters: air pressure valve actuator and valve plug displacement. With the use of fuzzy logic, these parameters are interpreted. They suffer inferences by rules written by experts in valves. After these inferences, the information is processed and sent as output signals

  13. Investigation on Bond-Slip Behavior of Z-Pin Interfaces in X-Cor® Sandwich Structures Using Z-Pin Pull-Out Test

    Science.gov (United States)

    Shan, Hangying; Xiao, Jun; Chu, Qiyi

    2018-05-01

    The Z-Pin interfacial bond properties play an important role in the structural performance of X-Cor® sandwich structures. This paper presents an experimental investigation on bond-slip behavior of Z-Pin interfaces using Z-Pin pull-out test. Based on the experimental data the whole Z-Pin pull-out process consists of three stages: initial bonding, debonding and frictional sliding. Comparative experimental study on the influence of design parameters on bond-slip behavior of Z-Pin interfaces has also been performed. Numerical analyses were conducted with the ABAQUS finite element (FE) program to simulate the Z-Pins bond-slip response of the pull-out test. The Z-Pins interfacial bond-slip behavior was implemented using nonlinear spring elements characterized with the constitutive relation from experimental results. Numerical results were validated by comparison with experimental data, and reasonably good agreement was achieved between experimental and analytical pull-out force-slip curves.

  14. Development of manufacturing equipment and QC equipment for DUPIC fuel

    International Nuclear Information System (INIS)

    Yang, Myung Seung; Park, J.J.; Lee, J.W.; Kim, S.S.; Yim, S.P.; Kim, J.H.; Kim, K.H.; Na, S.H.; Kim, W.K.; Shin, J.M.; Lee, D.Y.; Cho, K.H.; Lee, Y.S.; Sohn, J.S.; Kim, M.J.

    1999-05-01

    In this study, DUPIC powder and pellet fabrication equipment, welding system, QC equipment, and fission gas treatment are developed to fabricate DUPIC fuel at IMEF M6 hot cell. The systems are improved to be suitable for remote operation and maintenance with the manipulator at hot cell. Powder and pellet fabrication equipment have been recently developed. The systems are under performance test to check remote operation and maintenance. Welding chamber and jigs are designed and developed to remotely weld DUPIC fuel rod with manipulators at hot cell. Remote quality control equipment are being tested for analysis and inspection of DUPIC fuel characteristics at hot cell. And trapping characteristics is analyzed for cesium and ruthenium released under oxidation/reduction and sintering processes. The design criteria and process flow diagram of fission gas treatment system are prepared incorporating the experimental results. The fission gas treatment system has been successfully manufactured. (Author). 33 refs., 14 tabs., 91 figs

  15. Design of EPON far-end equipment based on FTTH

    Science.gov (United States)

    Feng, Xiancheng; Yun, Xiang

    2008-12-01

    Now, most favors fiber access is mainly the EPON fiber access system. Inheriting from the low cost of Ethernet, usability and bandwidth of optical network, EPON technology is one of the best technologies in fiber access and is adopted by the carriers all over the world widely. According to the scheme analysis to FTTH fan-end equipment, hardware design of ONU is proposed in this paper. The FTTH far-end equipment software design deference modulation design concept, it divides the software designment into 5 function modules: the module of low-layer driver, the module of system management, the module of master/slave communication, and the module of main/Standby switch and the module of command line. The software flow of the host computer is also analyzed. Finally, test is made for Ethernet service performance of FTTH far-end equipment, E1 service performance and the optical path protection switching, and so on. The results of test indicates that all the items are accordance with technical request of far-end ONU equipment and possess good quality and fully reach the requirement of telecommunication level equipment. The far-end equipment of FTTH divides into several parts based on the function: the control module, the exchange module, the UNI interface module, the ONU module, the EPON interface module, the network management debugging module, the voice processing module, the circuit simulation module, the CATV module. In the downstream direction, under the protect condition, we design 2 optical modules. The system can set one group optical module working and another group optical module closure when it is initialized. When the optical fiber line is cut off, the LOS warning comes out. It will cause MUX to replace another group optical module, simultaneously will reset module 3701/3711 and will make it again test the distance, and will give the plug board MPC850 report through the GPIO port. During normal mode, the downstream optical signal is transformed into the

  16. Microprocessor interfacing

    CERN Document Server

    Vears, R E

    2014-01-01

    Microprocessor Interfacing provides the coverage of the Business and Technician Education Council level NIII unit in Microprocessor Interfacing (syllabus U86/335). Composed of seven chapters, the book explains the foundation in microprocessor interfacing techniques in hardware and software that can be used for problem identification and solving. The book focuses on the 6502, Z80, and 6800/02 microprocessor families. The technique starts with signal conditioning, filtering, and cleaning before the signal can be processed. The signal conversion, from analog to digital or vice versa, is expl

  17. Developing equipment for AGR remote visual inspection

    International Nuclear Information System (INIS)

    James, P.W.; Walton, P.J.

    1985-01-01

    The Remote Inspection Group is part of the CEGB's Generation Development and Construction Division, and has responsibility for the design, development, procurement, testing and setting to work of the equipment provided to carry out routine remote visual inspections of its AGRs. This equipment includes both the viewing devices and the necessary placement equipment. (author)

  18. Investigation of the performance of digital mammographic X-Ray equipment: Determination of noise equivalent quanta (NEQQC) and detective quantum efficiency (DQEQC) compared with the automated analysis of CDMAM test images with CDCOM and CDIC programs

    International Nuclear Information System (INIS)

    Loos, C.; Buhr, H.; Blendl, C.

    2013-01-01

    Purpose: The purpose of this study was to determine the values for noise equivalent quanta, detective quantum efficiency, modulation transfer function, noise power spectrum, and the values for the parameters for automated CDMAM test phantom analyses required to achieve satisfactory quality of digital mammograms. Materials and Methods: During the course of tests according to PAS 1054 (8 CR and 12 DR systems), test images were made with a test phantom insertion plate containing two lead edges in nearly horizontal and vertical directions. Only original data were processed with a program that was developed at the Cologne University of Applied Sciences (FH-Koeln). All equipment systems complied with the requirements regarding visual recognition of gold-plated mammo detail test objects. CDMAM test images were also evaluated using the CDIC (CUAS) and CDCOM (EUREF) programs. Results: CDMAM test images show comparable values for the parameters, precision, sensitivity and specificity. DR systems require about half the dose used for CR systems for similar results. The NEQ values achieved with the dose used for the CDMAM test images show larger scatter ranges. The MTF of the different equipment system types differ significantly from each other. Conclusion: Visual evaluation of CDMAM test images can be replaced by automated evaluation. Limiting values were determined for each parameter. Automated evaluation of CDMAM test phantom images should be used to determine the physical parameter NEQ QC . This method is much more sensitive to noise and sharpness influences and has a higher validity than diagnostic methods. Automated evaluation objectivizes testing. (orig.)

  19. Diagnostic interface problems on TFTR

    International Nuclear Information System (INIS)

    Goldfarb, S.

    1977-01-01

    Diagnostic equipment on TFTR has functional interfaces with many machine systems. Salient requirements include plasma access, environmental resistance to thermal, magnetic and radiation effects, automated data acquisition and controls, remote handling and personnel safety. Problems imposed by these requirements and the solutions being considered are described

  20. Interface Anywhere

    Data.gov (United States)

    National Aeronautics and Space Administration — Current paradigms for crew interfaces to the systems that require control are constrained by decades old technologies which require the crew to be physically near an...

  1. User interface for MAWST limit of error program

    International Nuclear Information System (INIS)

    Crain, B. Jr.

    1991-01-01

    This paper reports on a user-friendly interface which is being developed to aid in preparation of input data for the Los Alamos National Laboratory software module MAWST (Materials Accounting With Sequential Testing) used at Savannah River Site to propagate limits of error for facility material balances. The forms-based interface is being designed using traditional software project management tools and using the Ingres family of database management and application development products (products of Relational Technology, Inc.). The software will run on VAX computers (products of Digital Equipment Corporation) on which the VMS operating system and Ingres database management software are installed. Use of the interface software will reduce time required to prepare input data for calculations and also reduce errors associated with data preparation

  2. Management of the interfaces between construction and startup

    International Nuclear Information System (INIS)

    Anderson, W.R.; Beatty, D.C.

    1976-01-01

    Many papers have been presented, and many articles published on the various tasks of Nuclear Plant Design, Construction, Startup and Operations. Most of the presentations have been concerned with the complexities of the particular task being discussed. This is as it should be, since these areas are quite broad in themselves and deserve the full attention of the technology. Recently more attention is being directed to the interfaces between the classical portions of nuclear projects. The paper attempts to address just one of these areas: the interfaces between construction and startup. These interfaces have normally been addressed to the extent that engineering schedules, construction schedules, equipment deliveries and startup test schedules have been dovetailed graphically, or computerized, and periodically updated to reflect significant changes

  3. New methodology to investigate potential contaminant mass fluxes at the stream-aquifer interface by combining integral pumping tests and streambed temperatures

    International Nuclear Information System (INIS)

    Kalbus, E.; Schmidt, C.; Bayer-Raich, M.; Leschik, S.; Reinstorf, F.; Balcke, G.U.; Schirmer, M.

    2007-01-01

    The spatial pattern and magnitude of mass fluxes at the stream-aquifer interface have important implications for the fate and transport of contaminants in river basins. Integral pumping tests were performed to quantify average concentrations of chlorinated benzenes in an unconfined aquifer partially penetrated by a stream. Four pumping wells were operated simultaneously for a time period of 5 days and sampled for contaminant concentrations. Streambed temperatures were mapped at multiple depths along a 60 m long stream reach to identify the spatial patterns of groundwater discharge and to quantify water fluxes at the stream-aquifer interface. The combined interpretation of the results showed average potential contaminant mass fluxes from the aquifer to the stream of 272 μg m -2 d -1 MCB and 71 μg m -2 d -1 DCB, respectively. This methodology combines a large-scale assessment of aquifer contamination with a high-resolution survey of groundwater discharge zones to estimate contaminant mass fluxes between aquifer and stream. - We provide a new methodology to quantify the potential contaminant mass flux from an aquifer to a stream

  4. Simulator tests for further development of the nuclear power plant's man-machine interface, the control room

    International Nuclear Information System (INIS)

    Becker, G.

    1988-01-01

    Methods for registration and analysis of the behavior of operators during simulated failures are described. Operator strategies and team work are addressed, as well as technical and psychological possibilities and limits of simulation experiments. The transferability of the test experiences is discussed and further projects are sketched out. 7 figs., 10 refs

  5. Phase 1 Integrated Systems Test and Characterization Report for the 5-Megawatt Dynamometer and Controllable Grid Interface

    Energy Technology Data Exchange (ETDEWEB)

    Wallen, Robert B [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Lambert, Scott R [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Gevorgian, Vahan [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Dana, Scott [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2018-03-13

    This report details the commissioning of the 5-megawatt dynamometer at the National Wind Technology Center at the National Renewable Energy Laboratory. The purpose of these characterization tests were to verify the dynamometer's performance over the widest possible range of operating conditions, gain insight into system-level behavior, and establish confidence in measurement data.

  6. Extreme testing of undiluted e-cigarette aerosol in vitro using an Ames air-agar-interface technique.

    Science.gov (United States)

    Thorne, D; Hollings, M; Seymour, A; Adamson, J; Dalrymple, A; Ballantyne, M; Gaca, M

    2018-04-01

    There is a growing consensus that e-cigarettes hold the potential for reducing the harm associated with cigarette smoking. Recently published studies have reported in vitro testing of e-cigarettes, demonstrating reduced toxicological and biological effects. Few studies however have reported the use of e-cigarettes under extreme testing conditions. To assess the full mutagenic potential of a commercially available electronic-cigarette (Vype ePen), this study investigated the delivery of aerosol under extreme conditions, using a scaled-down 35 mm plate Ames bacterial reverse mutagenicity assay. S. typhimurium strains TA98, TA100, TA97, TA104 and E. coli WP2 uvrA pKM101 with or without metabolic activation (S9), were employed. Using a modified Vitrocell VC 10 exposure system 0, 180, 360, 540, 720 or 900 puffs of undiluted e-cigarette aerosol was generated and delivered to bacterial cultures aligned to reported human consumption data. The results demonstrate that no mutagenic activity was observed in any strain under any test condition even when exposed to 900 puffs of undiluted e-cigarette aerosols +/- S9. Positive control responses were observed in all strains +/- S9. Nicotine assessments demonstrated an increased and consistent aerosol delivery, with calculated maximum doses of ∼1 mg/mL delivery of nicotine. These data demonstrate the validity of this unique testing approach and adds further information to the growing weight of evidence that e-cigarettes offer substantially reduced exposure when compared to conventional cigarette smoke. For future in vitro assessments of next generation tobacco and nicotine products, the generation, delivery and testing of undiluted aerosols can now be considered. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  7. [Development of Hospital Equipment Maintenance Information System].

    Science.gov (United States)

    Zhou, Zhixin

    2015-11-01

    Hospital equipment maintenance information system plays an important role in improving medical treatment quality and efficiency. By requirement analysis of hospital equipment maintenance, the system function diagram is drawed. According to analysis of input and output data, tables and reports in connection with equipment maintenance process, relationships between entity and attribute is found out, and E-R diagram is drawed and relational database table is established. Software development should meet actual process requirement of maintenance and have a friendly user interface and flexible operation. The software can analyze failure cause by statistical analysis.

  8. Automation of a thermogravimetric equipment

    International Nuclear Information System (INIS)

    Mussio, L.; Castiglioni, J.; Diano, W.

    1987-01-01

    A low cost automation of some instruments by means of simple electronic circuits and a microcomputer Apple IIe. type is discussed. The electronic circuits described are: a) a position detector including phototransistors connected as differential amplifier; b) a current source that, using the error signal of the position detector, changes the current through the coil of an electromagnetic balance to restore its zero position; c) a proportional temperature controller, zero volt switching to drive a furnace to a desired temperature; d) an interface temperature regulator-microcomputer to control the temperature regulator by software; e) a multiplexer for an analog input of a commercial interface. Those circuits are applied in a thermogravimetric equipment used also for vapours adsorption. A program in block diagram form is included and is able to record change of mass, time, furnace temperature and to drive the temperature regulator in order to have the heating rates or the temperature plateaux needed for the experiment. (author) [pt

  9. The technical supervision interface

    CERN Document Server

    Sollander, P

    1998-01-01

    The Technical Control Room (TCR) is currently using 30 different applications for the remote supervision of the technical infrastructure at CERN. These applications have all been developed with the CERN made Uniform Man Machine Interface (UMMI) tools built in 1990. However, the visualization technology has evolved phenomenally since 1990, the Technical Data Server (TDS) has radically changed our control system architecture, and the standardization and the maintenance of the UMMI applications have become important issues as their number increases. The Technical Supervision Interface is intended to replace the UMMI and solve the above problems. Using a standard WWW-browser for the display, it will be inherently multi-platform and hence available for control room operators, equipment specialists and on-call personnel.

  10. Presentation of laboratory test results in patient portals: influence of interface design on risk interpretation and visual search behaviour.

    Science.gov (United States)

    Fraccaro, Paolo; Vigo, Markel; Balatsoukas, Panagiotis; van der Veer, Sabine N; Hassan, Lamiece; Williams, Richard; Wood, Grahame; Sinha, Smeeta; Buchan, Iain; Peek, Niels

    2018-02-12

    Patient portals are considered valuable instruments for self-management of long term conditions, however, there are concerns over how patients might interpret and act on the clinical information they access. We hypothesized that visual cues improve patients' abilities to correctly interpret laboratory test results presented through patient portals. We also assessed, by applying eye-tracking methods, the relationship between risk interpretation and visual search behaviour. We conducted a controlled study with 20 kidney transplant patients. Participants viewed three different graphical presentations in each of low, medium, and high risk clinical scenarios composed of results for 28 laboratory tests. After viewing each clinical scenario, patients were asked how they would have acted in real life if the results were their own, as a proxy of their risk interpretation. They could choose between: 1) Calling their doctor immediately (high interpreted risk); 2) Trying to arrange an appointment within the next 4 weeks (medium interpreted risk); 3) Waiting for the next appointment in 3 months (low interpreted risk). For each presentation, we assessed accuracy of patients' risk interpretation, and employed eye tracking to assess and compare visual search behaviour. Misinterpretation of risk was common, with 65% of participants underestimating the need for action across all presentations at least once. Participants found it particularly difficult to interpret medium risk clinical scenarios. Participants who consistently understood when action was needed showed a higher visual search efficiency, suggesting a better strategy to cope with information overload that helped them to focus on the laboratory tests most relevant to their condition. This study confirms patients' difficulties in interpreting laboratories test results, with many patients underestimating the need for action, even when abnormal values were highlighted or grouped together. Our findings raise patient safety

  11. Lifetime assessment of atomic-layer-deposited Al2O3-Parylene C bilayer coating for neural interfaces using accelerated age testing and electrochemical characterization.

    Science.gov (United States)

    Minnikanti, Saugandhika; Diao, Guoqing; Pancrazio, Joseph J; Xie, Xianzong; Rieth, Loren; Solzbacher, Florian; Peixoto, Nathalia

    2014-02-01

    The lifetime and stability of insulation are critical features for the reliable operation of an implantable neural interface device. A critical factor for an implanted insulation's performance is its barrier properties that limit access of biological fluids to the underlying device or metal electrode. Parylene C is a material that has been used in FDA-approved implantable devices. Considered a biocompatible polymer with barrier properties, it has been used as a substrate, insulation or an encapsulation for neural implant technology. Recently, it has been suggested that a bilayer coating of Parylene C on top of atomic-layer-deposited Al2O3 would provide enhanced barrier properties. Here we report a comprehensive study to examine the mean time to failure of Parylene C and Al2O3-Parylene C coated devices using accelerated lifetime testing. Samples were tested at 60°C for up to 3 months while performing electrochemical measurements to characterize the integrity of the insulation. The mean time to failure for Al2O3-Parylene C was 4.6 times longer than Parylene C coated samples. In addition, based on modeling of the data using electrical circuit equivalents, we show here that there are two main modes of failure. Our results suggest that failure of the insulating layer is due to pore formation or blistering as well as thinning of the coating over time. The enhanced barrier properties of the bilayer Al2O3-Parylene C over Parylene C makes it a promising candidate as an encapsulating neural interface. Copyright © 2013 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  12. Repartition of ultrasonic energies at the interfaces

    International Nuclear Information System (INIS)

    Deleuze, M.; Bourdarios, M.; Lepoutre, M.

    1983-06-01

    Energy repartition of ultrasonic waves at the interfaces is studied as a function of incidence angle of the acoustic beam in immersion testing. For each interface type mathematical relations give the ratio of incident energy and energy of the wave reemitted by the interface. As an example curves for the interfaces water-uranium are given [fr

  13. Human-machine interface upgrade

    International Nuclear Information System (INIS)

    Kropik, M.; Matejka, K.; Sklenka, L.; Chab, V.

    2002-01-01

    The article describes a new human-machine interface that was installed at the VR-1 training reactor. The human-machine interface upgrade was completed in the summer 2001. The interface was designed with respect to functional, ergonomic and aesthetic requirements. The interface is based on a personal computer equipped with two displays. One display enables alphanumeric communication between the reactor operator and the nuclear reactor I and C. The second display is a graphical one. It presents the status of the reactor, principal parameters (as power, period), control rods positions, course of the reactor power. Furthermore, it is possible to set parameters, to show the active core configuration, to perform reactivity calculations, etc. The software for the new human-machine interface was produced with the InTouch developing tool of the Wonder-Ware Company. It is possible to switch the language of the interface between Czech and English because of many foreign students and visitors to the reactor. Microcomputer based communication units with proper software were developed to connect the new human-machine interface with the present reactor I and C. The new human-machine interface at the VR-1 training reactor improves the comfort and safety of the reactor utilisation, facilitates experiments and training, and provides better support for foreign visitors. (orig.)

  14. Identifying nurse staffing research in Medline: development and testing of empirically derived search strategies with the PubMed interface.

    Science.gov (United States)

    Simon, Michael; Hausner, Elke; Klaus, Susan F; Dunton, Nancy E

    2010-08-23

    The identification of health services research in databases such as PubMed/Medline is a cumbersome task. This task becomes even more difficult if the field of interest involves the use of diverse methods and data sources, as is the case with nurse staffing research. This type of research investigates the association between nurse staffing parameters and nursing and patient outcomes. A comprehensively developed search strategy may help identify nurse staffing research in PubMed/Medline. A set of relevant references in PubMed/Medline was identified by means of three systematic reviews. This development set was used to detect candidate free-text and MeSH terms. The frequency of these terms was compared to a random sample from PubMed/Medline in order to identify terms specific to nurse staffing research, which were then used to develop a sensitive, precise and balanced search strategy. To determine their precision, the newly developed search strategies were tested against a) the pool of relevant references extracted from the systematic reviews, b) a reference set identified from an electronic journal screening, and c) a sample from PubMed/Medline. Finally, all newly developed strategies were compared to PubMed's Health Services Research Queries (PubMed's HSR Queries). The sensitivities of the newly developed search strategies were almost 100% in all of the three test sets applied; precision ranged from 6.1% to 32.0%. PubMed's HSR queries were less sensitive (83.3% to 88.2%) than the new search strategies. Only minor differences in precision were found (5.0% to 32.0%). As with other literature on health services research, nurse staffing studies are difficult to identify in PubMed/Medline. Depending on the purpose of the search, researchers can choose between high sensitivity and retrieval of a large number of references or high precision, i.e. and an increased risk of missing relevant references, respectively. More standardized terminology (e.g. by consistent use of the

  15. Control of hydrogen sulfide emission from geothermal power plants. Volume III. Final report: demonstration plant equipment descriptions, test plan, and operating instructions

    Energy Technology Data Exchange (ETDEWEB)

    Brown, F.C.; Harvey, W.W.; Warren, R.B.

    1977-01-01

    The elements of the final, detailed design of the demonstration plant for the copper sulfate process for the removal of hydrogen sulfide from geothermal steam are summarized. Descriptions are given of all items of equipment in sufficient detail that they can serve as purchase specifications. The process and mechanical design criteria which were used to develop the specifications, and the process descriptions and material and energy balance bases to which the design criteria were applied are included. (MHR)

  16. Playful user interfaces interfaces that invite social and physical interaction

    CERN Document Server

    2014-01-01

    The book is about user interfaces to applications that have been designed for social and physical interaction. The interfaces are ‘playful’, that is, users feel challenged to engage in social and physical interaction because that will be fun. The topics that will be present in this book are interactive playgrounds, urban games using mobiles, sensor-equipped environments for playing, child-computer interaction, tangible game interfaces, interactive tabletop technology and applications, full-body interaction, exertion games, persuasion, engagement, evaluation, and user experience. Readers of the book will not only get a survey of state-of-the-art research in these areas, but the chapters in this book will also provide a vision of the future where playful interfaces will be ubiquitous, that is, present and integrated in home, office, recreational, sports and urban environments, emphasizing that in the future in these environments game elements will be integrated and welcomed.

  17. Designing Interfaces

    CERN Document Server

    Tidwell, Jenifer

    2010-01-01

    Despite all of the UI toolkits available today, it's still not easy to design good application interfaces. This bestselling book is one of the few reliable sources to help you navigate through the maze of design options. By capturing UI best practices and reusable ideas as design patterns, Designing Interfaces provides solutions to common design problems that you can tailor to the situation at hand. This updated edition includes patterns for mobile apps and social media, as well as web applications and desktop software. Each pattern contains full-color examples and practical design advice th

  18. Interface unit

    NARCIS (Netherlands)

    Keyson, D.V.; Freudenthal, A.; De Hoogh, M.P.A.; Dekoven, E.A.M.

    2001-01-01

    The invention relates to an interface unit comprising at least a display unit for communication with a user, which is designed for being coupled with a control unit for at least one or more parameters in a living or working environment, such as the temperature setting in a house, which control unit

  19. Operational test procedure for SY tank farm replacement exhauster unit

    International Nuclear Information System (INIS)

    McClees, J.

    1995-01-01

    This operational test procedure will verify that the remaining functions not tested per WHC-SD-WM-ATP-080, or components disturbed during final installation, as well as interfaces with other tank farm equipment and remote monitoring stations are operating correctly

  20. Interface superconductivity

    Energy Technology Data Exchange (ETDEWEB)

    Gariglio, S., E-mail: stefano.gariglio@unige.ch [DQMP, Université de Genève, 24 Quai E.-Ansermet, CH-1211 Genève (Switzerland); Gabay, M. [Laboratoire de Physique des Solides, Bat 510, Université Paris-Sud 11, Centre d’Orsay, 91405 Orsay Cedex (France); Mannhart, J. [Max Planck Institute for Solid State Research, 70569 Stuttgart (Germany); Triscone, J.-M. [DQMP, Université de Genève, 24 Quai E.-Ansermet, CH-1211 Genève (Switzerland)

    2015-07-15

    Highlights: • We discuss interfacial superconductivity, a field boosted by the discovery of the superconducting interface between LaAlO. • This system allows the electric field control and the on/off switching of the superconducting state. • We compare superconductivity at the interface and in bulk doped SrTiO. • We discuss the role of the interfacially induced Rashba type spin–orbit. • We briefly discuss superconductivity in cuprates, in electrical double layer transistor field effect experiments. • Recent observations of a high T{sub c} in a monolayer of FeSe deposited on SrTiO{sub 3} are presented. - Abstract: Low dimensional superconducting systems have been the subject of numerous studies for many years. In this article, we focus our attention on interfacial superconductivity, a field that has been boosted by the discovery of superconductivity at the interface between the two band insulators LaAlO{sub 3} and SrTiO{sub 3}. We explore the properties of this amazing system that allows the electric field control and on/off switching of superconductivity. We discuss the similarities and differences between bulk doped SrTiO{sub 3} and the interface system and the possible role of the interfacially induced Rashba type spin–orbit. We also, more briefly, discuss interface superconductivity in cuprates, in electrical double layer transistor field effect experiments, and the recent observation of a high T{sub c} in a monolayer of FeSe deposited on SrTiO{sub 3}.