WorldWideScience

Sample records for environmental aqueous samples

  1. Tandem Extraction/Liquid Chromatography-Mass Spectrometry Protocol for the Analysis of Acrylamide and Surfactant-related Compounds in Complex Aqueous Environmental Samples

    Science.gov (United States)

    The development of a liquid chromatography‐mass spectrometry (LC‐MS)‐based strategy for the detection and quantitation of acrylamide and surfactant‐related compounds in aqueous complex environmental samples.

  2. Quantification and size characterisation of silver nanoparticles in environmental aqueous samples and consumer products by single particle-ICPMS.

    Science.gov (United States)

    Aznar, Ramón; Barahona, Francisco; Geiss, Otmar; Ponti, Jessica; José Luis, Tadeo; Barrero-Moreno, Josefa

    2017-12-01

    Single particle-inductively coupled plasma mass spectrometry (SP-ICPMS) is a promising technique able to generate the number based-particle size distribution (PSD) of nanoparticles (NPs) in aqueous suspensions. However, SP-ICPMS analysis is not consolidated as routine-technique yet and is not typically applied to real test samples with unknown composition. This work presents a methodology to detect, quantify and characterise the number-based PSD of Ag-NPs in different environmental aqueous samples (drinking and lake waters), aqueous samples derived from migration tests and consumer products using SP-ICPMS. The procedure is built from a pragmatic view and involves the analysis of serial dilutions of the original sample until no variation in the measured size values is observed while keeping particle counts proportional to the dilution applied. After evaluation of the analytical figures of merit, the SP-ICPMS method exhibited excellent linearity (r 2 >0.999) in the range (1-25) × 10 4 particlesmL -1 for 30, 50 and 80nm nominal size Ag-NPs standards. The precision in terms of repeatability was studied according to the RSDs of the measured size and particle number concentration values and a t-test (p = 95%) at the two intermediate concentration levels was applied to determine the bias of SP-ICPMS size values compared to reference values. The method showed good repeatability and an overall acceptable bias in the studied concentration range. The experimental minimum detectable size for Ag-NPs ranged between 12 and 15nm. Additionally, results derived from direct SP-ICPMS analysis were compared to the results conducted for fractions collected by asymmetric flow-field flow fractionation and supernatant fractions after centrifugal filtration. The method has been successfully applied to determine the presence of Ag-NPs in: lake water; tap water; tap water filtered by a filter jar; seven different liquid silver-based consumer products; and migration solutions (pure water and

  3. Comparison of two thin-film microextractions for the analysis of estrogens in aqueous tea extract and environmental water samples by high performance liquid chromatography-ultraviolet detection.

    Science.gov (United States)

    Cai, Pei-Shan; Li, Dan; Chen, Jing; Xiong, Chao-Mei; Ruan, Jin-Lan

    2015-04-15

    Two thin-film microextractions (TFME), octadecylsilane (ODS)-polyacrylonitrile (PAN)-TFME and polar enhanced phase (PEP)-PAN-TFME have been proposed for the analysis of bisphenol-A, diethylstilbestrol and 17β-estradiol in aqueous tea extract and environmental water samples followed by high performance liquid chromatography-ultraviolet detection. Both thin-films were prepared by spraying. The influencing factors including pH, extraction time, desorption solvent, desorption volume, desorption time, ion strength and reusability were investigated. Under the optimal conditions, the two TFME methods are similar in terms of the analytical performance evaluated by standard addition method. The limits of detection for three estrogens in environmental water and aqueous tea extract matrix ranged from 1.3 to 1.6 and 2.8 to 7.1 ng mL(-1) by the two TFME methods, respectively. Both approaches were applied for the analysis of analytes in real aqueous tea extract and environmental water samples, presenting satisfactory recoveries ranged from 87.3% to 109.4% for the spiked samples. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. On-line speciation analysis of inorganic arsenic in complex environmental aqueous samples by pervaporation sequential injection analysis.

    Science.gov (United States)

    Boonjob, Warunya; Miró, Manuel; Kolev, Spas D

    2013-12-15

    A proof of concept of a novel pervaporation sequential injection (PSI) analysis method for automatic non-chromatographic speciation analysis of inorganic arsenic in complex aqueous samples is presented. The method is based on hydride generation of arsine followed by its on-line pervaporation-based membrane separation and CCD spectrophotometric detection. The concentrations of arsenite (As(III)) and arsenate (As(V)) are determined sequentially in a single sample zone. The leading section of the sample zone merges with a citric acid/citrate buffer solution (pH 4.5) for the selective reduction of As(III) to arsine while the trailing section of the sample zone merges with hydrochloric acid solution to allow the reduction of both As(III) and As(V) to arsine at pH lower than 1. Virtually identical analytical sensitivity is obtained for both As(III) and As(V) at this high acidity. The flow analyzer also accommodates in-line pH detector for monitoring of the acidity throughout the sample zone prior to hydride generation. Under optimal conditions the proposed PSI method is characterized by a limit of detection, linear calibration range and repeatability for As(III) of 22 μg L(-1) (3sblank level criterion), 50-1000 μg L(-1) and 3.0% at the 500 μg L(-1) level and for As(V) of 51 μg L(-1), 100-2000 μg L(-1) and 2.6% at the 500 μg L(-1) level, respectively. The method was validated with mixed As(III)/As(V) standard aqueous solutions and successfully applied to the determination of As(III) and As(V) in river water samples with elevated content of dissolved organic carbon and suspended particulate matter with no prior sample pretreatment. Excellent relative recoveries ranging from 98% to 104% were obtained for both As(III) and As(V). © 2013 Elsevier B.V. All rights reserved.

  5. A highly sensitive monoclonal antibody based biosensor for quantifying 3–5 ring polycyclic aromatic hydrocarbons (PAHs in aqueous environmental samples

    Directory of Open Access Journals (Sweden)

    Xin Li

    2016-03-01

    Full Text Available Immunoassays based on monoclonal antibodies (mAbs are highly sensitive for the detection of polycyclic aromatic hydrocarbons (PAHs and can be employed to determine concentrations in near real-time. A sensitive generic mAb against PAHs, named as 2G8, was developed by a three-step screening procedure. It exhibited nearly uniformly high sensitivity against 3-ring to 5-ring unsubstituted PAHs and their common environmental methylated PAHs, with IC50 values between 1.68 and 31 μg/L (ppb. 2G8 has been successfully applied on the KinExA Inline Biosensor system for quantifying 3–5 ring PAHs in aqueous environmental samples. PAHs were detected at a concentration as low as 0.2 μg/L. Furthermore, the analyses only required 10 min for each sample. To evaluate the accuracy of the 2G8-based biosensor, the total PAH concentrations in a series of environmental samples analyzed by biosensor and GC–MS were compared. In most cases, the results yielded a good correlation between methods. This indicates that generic antibody 2G8 based biosensor possesses significant promise for a low cost, rapid method for PAH determination in aqueous samples. Keywords: Monoclonal antibody, PAH, Pore water, Biosensor, Pyrene

  6. Comparison of the Usefulness of SPE Cartridges for the Determination of β-Blockers and β-Agonists (Basic Drugs in Environmental Aqueous Samples

    Directory of Open Access Journals (Sweden)

    Magda Caban

    2015-01-01

    Full Text Available Even though the methodology used for the determination of β-blockers and β-agonists in environmental samples is based mainly on solid-phase extraction (SPE and gas chromatography or liquid chromatography with mass spectrometric detection, the available literature data on the applied SPE procedures is rather sparse. In this paper such comparison is presented. Moreover, the usefulness of the eight SPE cartridges for the determination of five β-blockers (acebutolol, atenolol, metoprolol, nadolol, and propranolol and two β-agonists (salbutamol and terbutaline in environmental aqueous samples using GC techniques is tested. Among them, three (the trifunction sorbent Strata Screen C, the copolymers LiChrolut EN, and the functionalized copolymer Isolute ENV+ were used for the first time for this purpose. It was confirmed that polystyrene-divinylbenzene-N-vinylpyrrolidone copolymers (PS-DVB-VP, Strata-X, and Oasis HLB cartridges have a better potential than a cation-exchange sorbent for the extraction of the target drugs from environmental water samples. However, it should be stressed out that the direct application of the tested SPE conditions for the analysis of real environmental water samples is not possible, and such parameters, like volume of loading sample, appropriate solvents for washing and elution steps, and so forth, must be optimized again in order to achieve satisfactory recovery values for the target compounds.

  7. Three-dimensional printed knotted reactors enabling highly sensitive differentiation of silver nanoparticles and ions in aqueous environmental samples

    International Nuclear Information System (INIS)

    Su, Cheng-Kuan; Hsieh, Meng-Hsuan; Sun, Yuh-Chang

    2016-01-01

    Whether silver nanoparticles (AgNPs) persist or release silver ions (Ag + ) when discharged into a natural environment has remained an unresolved issue. In this study, we employed a low-cost stereolithographic three-dimensional printing (3DP) technology to fabricate the angle-defined knotted reactors (KRs) to construct a simple differentiation scheme for quantitative assessment of Ag + ions and AgNPs in municipal wastewater samples. We chose xanthan/phosphate-buffered saline as a dispersion medium for in situ stabilization of the two silver species, while also facilitating their extraction from complicated wastewater matrices. After method optimization, we measured extraction efficiencies of 54.5 and 32.3% for retaining Ag + ions and AgNPs, respectively, in the printed KR (768-turn), with detection limits (DLs) of 0.86 and 0.52 ng L −1 when determining Ag + ions and AgNPs, respectively (sample run at pH 11 without a rinse solution), and 0.86 ng L −1 when determining Ag + ions alone (sample run at pH 12 with a 1.5-mL rinse solution). The proposed scheme is tolerant of the wastewater matrix and provides more reliable differentiation between Ag + /AgNPs than does a conventional filtration method. The concept and applicability of adopting 3DP technology to renew traditional KR devices were evidently proven by means of these significantly improved analytical performance. Our analytical data suggested that the concentrations of Ag + ions and AgNPs in the tested industrial wastewater sample were both higher than those in domestic wastewater, implying that industrial activity might be a main source of environmental silver species, rather than domestic discharge from AgNP-containing products. - Highlights: • 3D printed knotted reactors are utilized to differentiate AgNPs and Ag + ions. • Xanthan/phosphate-buffered saline is used for stabilizing the two silver species. • Extraction efficiency up to 54.5% is available for retaining Ag + ion species. • The

  8. Inter-laboratory exercise on steroid estrogens in aqueous samples

    Energy Technology Data Exchange (ETDEWEB)

    Heath, E., E-mail: ester.heath@ijs.s [Department of Environmental Sciences, Jozef Stefan Institute, Jamova 39, 1000 Ljubljana (Slovenia); Kosjek, T. [Department of Environmental Sciences, Jozef Stefan Institute, Jamova 39, 1000 Ljubljana (Slovenia); Andersen, H.R.; Holten Luetzhoft, H.-C. [Department of Environmental Engineering, Technical University of Denmark, Miljoevej 113, DK-2800 Kgs. Lyngby (Denmark); Adolfson Erici, M. [Stockholm University, ITM SE-106 91 Stockholm (Sweden); Coquery, M. [Cemagref, U.R. QELY, F-69336 Lyon (France); Duering, R.-A. [Giessen University, Institute of Soil Science and Soil Conservation, Giessen (Germany); Gans, O. [Umweltbundesamt GmbH, Unit Organic Analysis, Spittelauer Laende 5, 1090 Vienna (Austria); Guignard, C. [CRP Gabriel Lippmann, EVA, 41 rue du Brill, L-4422 Belvaux (Luxembourg); Karlsson, P. [Lantmannen Analycen AB, Research and Development, Sjoehagsgatan 3 Box 905, 5319, Lidkoeping (Sweden); Manciot, F. [CAE VEOLIA ENVIRONMENT, 1 Place de Turenne, 94417 Saint Maurice Cedex (France); Moldovan, Z. [National Institute of Research and Development for Isotopic and Molecular Technology, Mass Spectrometry Department, Str. Donath 65-103, 400293 Cluj-Napoca (Romania); Patureau, D. [INRA, UR50, Laboratoire de Biotechnologie de l' Environnemet (LBE), Avenue des etangs, F-11100 Narbonne (France); Cruceru, L. [Pollution Control Department, National Research Institute for Industrial Ecology (ECOIND), Sos.Panduri 90-92, sector 5, Bucharest (Romania); Sacher, F. [DVGW-Technologiezentrum Wasser, Karlsruher Strasse 84, 76139 Karlsruhe (Germany); Ledin, A. [Department of Environmental Engineering, Technical University of Denmark, Miljoevej 113, DK-2800 Kgs. Lyngby (Denmark)

    2010-03-15

    An inter-laboratory comparison exercise was organized among European laboratories, under the aegis of EU COST Action 636: 'Xenobiotics in Urban Water Cycle'. The objective was to evaluate the performance of testing laboratories determining 'Endocrine Disrupting Compounds' (EDC) in various aqueous matrices. As the main task three steroid estrogens: 17alpha-ethinylestradiol, 17beta-estradiol and estrone were determined in four spiked aqueous matrices: tap water, river water and wastewater treatment plant influent and effluent using GC-MS and LC-MS/MS. Results were compared and discussed according to the analytical techniques applied, the accuracy and reproducibility of the analytical methods and the nature of the sample matrices. Overall, the results obtained in this inter-laboratory exercise reveal a high level of competence among the participating laboratories for the detection of steroid estrogens in water samples indicating that GC-MS as well as LC-MS/MS can equally be employed for the analysis of natural and synthetic hormones. - Herein are presented the results of the first international inter-laboratory study on determination of selected steroid hormones in environmental aqueous samples.

  9. Determination of adsorbable organic fluorine from aqueous environmental samples by adsorption to polystyrene-divinylbenzene based activated carbon and combustion ion chromatography.

    Science.gov (United States)

    Wagner, Andrea; Raue, Brigitte; Brauch, Heinz-Jürgen; Worch, Eckhard; Lange, Frank T

    2013-06-21

    liquid chromatography-electrospray tandem mass spectrometry (HPLC-(-)ESI-MS/MS). In groundwater contaminated by PFC-containing aqueous film-forming foams (AFFFs) up to 50% of the AOF could be attributed to PFC target chemicals, while in diffuse contaminated samples only <5% of the AOF could be identified by PFC analysis. Copyright © 2013 Elsevier B.V. All rights reserved.

  10. Environmental sampling technician training program

    International Nuclear Information System (INIS)

    Moreland, W.M.

    1988-01-01

    The Oak Ridge National Laboratory (ORNL) is currently involved in extensive environmental monitoring activities to characterize various active/inactive waste sites that exist at the facility. There are also considerable reporting requirements that ORNL must meet on a continuing basis in order to remain in compliance with existing permit requirements under the Resource Conservation and Recovery Act (RCRA), the Clean Air Act (CAA), and the Clean Water Act (CWA). Much of the environmental monitoring data that is used to characterize waste sites or is required in reports is obtained by environmental sampling technicians who must take samples at various locations throughout ORNL as well as other DOE installations. Because of the quality control and assurance measures included under NQA-1, ORNL has developed an Environmental Sampling Technician Training program. This presentation will describe how the Environmental Sampling Technician Training Program was developed and review the specific materials used in conducting the training

  11. Environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1996-02-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL) for the US Department of Energy (DOE). This document contains the planned 1996 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project

  12. Environmental sampling for trace analysis

    International Nuclear Information System (INIS)

    Markert, B.

    1994-01-01

    Often too little attention is given to the sampling before and after actual instrumental measurement. This leads to errors, despite increasingly sensitive analytical systems. This is one of the first books to pay proper attention to representative sampling. It offers an overview of the most common techniques used today for taking environmental samples. The techniques are clearly presented, yield accurate and reproducible results and can be used to sample -air - water - soil and sediments - plants and animals. A comprehensive handbook, this volume provides an excellent starting point for researchers in the rapidly expanding field of environmental analysis. (orig.)

  13. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1993-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). Samples are routinely collected and analyzed to determine the quality of air, surface water, ground water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. This document contains the planned schedule for routine sample collection for the Surface Environmental Surveillance Project (SESP) and Drinking Water Project, and Ground-Water Surveillance Project.

  14. Environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1997-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL)(a) for the US Department of Energy (DOE). This document contains the planned 1997 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. In addition, Section 3.0, Biota, also reflects a rotating collection schedule identifying the year a specific sample is scheduled for collection. The purpose of these monitoring projects is to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5400.1, General Environmental Protection Program, and DOE Order 5400.5, Radiation Protection of the Public and the Environment. The sampling methods will be the same as those described in the Environmental Monitoring Plan, US Department of Energy, Richland Operations Office, DOE/RL91-50, Rev. 1, US Department of Energy, Richland, Washington

  15. Environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1995-02-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the U.S. Department of Energy (DOE). This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring onsite drinking water falls outside the scope of the SESP. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control, and reporting. The ground-water sampling schedule identifies ground-water sampling .events used by PNL for environmental surveillance of the Hanford Site. Sampling is indicated as annual, semi-annual, quarterly, or monthly in the sampling schedule. Some samples are collected and analyzed as part of ground-water monitoring and characterization programs at Hanford (e.g. Resources Conservation and Recovery Act (RCRA), Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), or Operational). The number of samples planned by other programs are identified in the sampling schedule by a number in the analysis column and a project designation in the Cosample column. Well sampling events may be merged to avoid redundancy in cases where sampling is planned by both-environmental surveillance and another program

  16. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1995-02-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the U.S. Department of Energy (DOE). This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring onsite drinking water falls outside the scope of the SESP. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control, and reporting. The ground-water sampling schedule identifies ground-water sampling .events used by PNL for environmental surveillance of the Hanford Site. Sampling is indicated as annual, semi-annual, quarterly, or monthly in the sampling schedule. Some samples are collected and analyzed as part of ground-water monitoring and characterization programs at Hanford (e.g. Resources Conservation and Recovery Act (RCRA), Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), or Operational). The number of samples planned by other programs are identified in the sampling schedule by a number in the analysis column and a project designation in the Cosample column. Well sampling events may be merged to avoid redundancy in cases where sampling is planned by both-environmental surveillance and another program.

  17. Soil sampling for environmental contaminants

    International Nuclear Information System (INIS)

    2004-10-01

    The Consultants Meeting on Sampling Strategies, Sampling and Storage of Soil for Environmental Monitoring of Contaminants was organized by the International Atomic Energy Agency to evaluate methods for soil sampling in radionuclide monitoring and heavy metal surveys for identification of punctual contamination (hot particles) in large area surveys and screening experiments. A group of experts was invited by the IAEA to discuss and recommend methods for representative soil sampling for different kinds of environmental issues. The ultimate sinks for all kinds of contaminants dispersed within the natural environment through human activities are sediment and soil. Soil is a particularly difficult matrix for environmental pollution studies as it is generally composed of a multitude of geological and biological materials resulting from weathering and degradation, including particles of different sizes with varying surface and chemical properties. There are so many different soil types categorized according to their content of biological matter, from sandy soils to loam and peat soils, which make analytical characterization even more complicated. Soil sampling for environmental monitoring of pollutants, therefore, is still a matter of debate in the community of soil, environmental and analytical sciences. The scope of the consultants meeting included evaluating existing techniques with regard to their practicability, reliability and applicability to different purposes, developing strategies of representative soil sampling for cases not yet considered by current techniques and recommending validated techniques applicable to laboratories in developing Member States. This TECDOC includes a critical survey of existing approaches and their feasibility to be applied in developing countries. The report is valuable for radioanalytical laboratories in Member States. It would assist them in quality control and accreditation process

  18. Determination of non ionic surfactants (BIAS) in aqueous samples

    International Nuclear Information System (INIS)

    Capri, S.; Patrolecco, L.; Zanette, M.; Marcomini, A.

    1996-01-01

    A series of experiments were carried out to solve the inconsistencies of the regulatory semispecific method for the determination of nonionic surfactants (BIAS) in aqueous samples and to evaluate precision, accuracy and applicability concentration range. Significant improvements of the protocol IRSA E-013 were introduced and the BIAS method was recently published, in revised form, in the IRSA Handbook of Water Analysis (Method 5160)

  19. Environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1991-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for the Surface Environmental Surveillance Project (SESP) and Ground-Water Monitoring Project. The routine sampling plan for the SESP has been revised this year to reflect changing site operations and priorities. Some sampling previously performed at least annually has been reduced in frequency, and some new sampling to be performed at a less than annual frequency has been added. Therefore, the SESP schedule reflects sampling to be conducted in calendar year 1991 as well as future years. The ground-water sampling schedule is for 1991. This schedule is subject to modification during the year in response to changes in Site operation, program requirements, and the nature of the observed results. Operational limitations such as weather, mechanical failures, sample availability, etc., may also require schedule modifications. Changes will be documented in the respective project files, but this plan will not be reissued. The purpose of these monitoring projects is to evaluate levels of radioactive and nonradioactive pollutants in the Hanford evirons

  20. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1991-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for the Surface Environmental Surveillance Project (SESP) and Ground-Water Monitoring Project. The routine sampling plan for the SESP has been revised this year to reflect changing site operations and priorities. Some sampling previously performed at least annually has been reduced in frequency, and some new sampling to be performed at a less than annual frequency has been added. Therefore, the SESP schedule reflects sampling to be conducted in calendar year 1991 as well as future years. The ground-water sampling schedule is for 1991. This schedule is subject to modification during the year in response to changes in Site operation, program requirements, and the nature of the observed results. Operational limitations such as weather, mechanical failures, sample availability, etc., may also require schedule modifications. Changes will be documented in the respective project files, but this plan will not be reissued. The purpose of these monitoring projects is to evaluate levels of radioactive and nonradioactive pollutants in the Hanford evirons.

  1. Sr-90 determination in aqueous and soils samples

    International Nuclear Information System (INIS)

    Gonzalez Sintas, Maria F.; Cerchietti, Maria L.; Arguelles, Maria G.

    2009-01-01

    The main objective of this paper is to evaluate the method for Sr-90 determination in aqueous sample and soils. Area and Personal Dosimetry laboratory (DPA) determines the presence of Sr-90 by Liquid Scintillation (LSC) by applying method of the double window and corresponding adjustments. Calibration is performed by standard solutions of 90 Sr/ 90 Y, where spectral 90 Sr and 90 Y zones are optimized. The initial treatment of the liquid samples includes the concentration for evaporation, while the solid ones dissolve for microwave and acidic digestion. The separation of the analyte involves a selective chromatographic extraction. An average efficiency for 90 Sr of 77 ± 1 % was obtained; the factor a/b was 0,85 ± 0,01 and recovery of 82 ± 8 %. The resultant MAD was 0,10 Bq/L in aqueous samples and 0,10 Bq/g in solid samples. (author)

  2. Environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1994-02-01

    This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring the onsite drinking water falls outside the scope of the SESP. The Hanford Environmental Health Foundation is responsible for monitoring the nonradiological parameters as defined in the National Drinking Water Standards while PNL conducts the radiological monitoring of the onsite drinking water. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize the expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control and reporting. The ground-water sampling schedule identifies ground-water sampling events used by PNL for environmental surveillance of the Hanford Site

  3. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1994-02-01

    This document contains the planned 1994 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP), Drinking Water Project, and Ground-Water Surveillance Project. Samples are routinely collected for the SESP and analyzed to determine the quality of air, surface water, soil, sediment, wildlife, vegetation, foodstuffs, and farm products at Hanford Site and surrounding communities. The responsibility for monitoring the onsite drinking water falls outside the scope of the SESP. The Hanford Environmental Health Foundation is responsible for monitoring the nonradiological parameters as defined in the National Drinking Water Standards while PNL conducts the radiological monitoring of the onsite drinking water. PNL conducts the drinking water monitoring project concurrent with the SESP to promote efficiency and consistency, utilize the expertise developed over the years, and reduce costs associated with management, procedure development, data management, quality control and reporting. The ground-water sampling schedule identifies ground-water sampling events used by PNL for environmental surveillance of the Hanford Site.

  4. Environmental surveillance master sampling schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L E

    1992-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for the Surface Environmental Surveillance Project (SESP) and Ground-Water Monitoring Project. Samples for radiological analyses include Air-Particulate Filter, gases and vapor; Water/Columbia River, Onsite Pond, Spring, Irrigation, and Drinking; Foodstuffs/Animal Products including Whole Milk, Poultry and Eggs, and Beef; Foodstuffs/Produce including Leafy Vegetables, Vegetables, and Fruit; Foodstuffs/Farm Products including Wine, Wheat and Alfalfa; Wildlife; Soil; Vegetation; and Sediment. Direct Radiation Measurements include Terrestrial Locations, Columbia River Shoreline Locations, and Onsite Roadway, Railway and Aerial, Radiation Surveys.

  5. Automated Aqueous Sample Concentration Methods for in situ Astrobiological Instrumentation

    Science.gov (United States)

    Aubrey, A. D.; Grunthaner, F. J.

    2009-12-01

    The era of wet chemical experiments for in situ planetary science investigations is upon us, as evidenced by recent results from the surface of Mars by Phoenix’s microscopy, electrochemistry, and conductivity analyzer, MECA [1]. Studies suggest that traditional thermal volatilization methods for planetary science in situ investigations induce organic degradation during sample processing [2], an effect that is enhanced in the presence of oxidants [3]. Recent developments have trended towards adaptation of non-destructive aqueous extraction and analytical methods for future astrobiological instrumentation. Wet chemical extraction techniques under investigation include subcritical water extraction, SCWE [4], aqueous microwave assisted extraction, MAE, and organic solvent extraction [5]. Similarly, development of miniaturized analytical space flight instruments that require aqueous extracts include microfluidic capillary electrophoresis chips, μCE [6], liquid-chromatography mass-spectrometrometers, LC-MS [7], and life marker chips, LMC [8]. If organics are present on the surface of Mars, they are expected to be present at extremely low concentrations (parts-per-billion), orders of magnitude below the sensitivities of most flight instrument technologies. Therefore, it becomes necessary to develop and integrate concentration mechanisms for in situ sample processing before delivery to analytical flight instrumentation. We present preliminary results of automated solid-phase-extraction (SPE) sample purification and concentration methods for the treatment of highly saline aqueous soil extracts. These methods take advantage of the affinity of low molecular weight organic compounds with natural and synthetic scavenger materials. These interactions allow for the separation of target organic analytes from unfavorable background species (i.e. salts) during inline treatment, and a clever method for selective desorption is utilized to obtain concentrated solutions on the order

  6. Inter-laboratory exercise on steroid estrogens in aqueous samples

    DEFF Research Database (Denmark)

    Heath, E.; Kosjek, T.; Andersen, Henrik Rasmus

    2010-01-01

    matrices. As the main task three steroid estrogens. 17 alpha-ethinylestradiol, 17 beta-estradiol and estrone were determined in four spiked aqueous matrices' tap water, river water and wastewater treatment plant influent and effluent using GC-MS and LC-MS/MS Results were compared and discussed according...... to the analytical techniques applied, the accuracy and reproducibility of the analytical methods and the nature of the sample matrices. Overall, the results obtained in this inter-laboratory exercise reveal a high level of competence among the participating laboratories for the detection of steroid estrogens...

  7. Analysis of Direct Samples of Early Solar System Aqueous Fluids

    Science.gov (United States)

    Zolensky, Michael E.; Bodnar, R J.; Fedele, L.; Yurimoto,H.; Itoh, S.; Fries, M.; Steele, A.

    2012-01-01

    Over the past three decades we have become increasingly aware of the fundamental importance of water, and aqueous alteration, on primitive solar-system bodies. Some carbonaceous and ordinary chondrites have been altered by interactions with liquid water within the first 10 million years after formation of their parent asteroids. Millimeter to centimeter-sized aggregates of purple halite containing aqueous fluid inclusions were found in the matrix of two freshly-fallen brecciated H chondrite falls, Monahans (1998, hereafter simply "Monahans") (H5) and Zag (H3-6) (Zolensky et al., 1999; Whitby et al., 2000; Bogard et al., 2001) In order to understand origin and evolution of the aqueous fluids inside these inclusions we much measure the actual fluid composition, and also learn the O and H isotopic composition of the water. It has taken a decade for laboratory analytical techniques to catch up to these particular nanomole-sized aqueous samples. We have recently been successful in (1) measuring the isotopic composition of H and O in the water in a few fluid inclusions from the Zag and Monahans halite, (2) mineralogical characterization of the solid mineral phases associated with the aqueous fluids within the halite, and (3) the first minor element analyses of the fluid itself. A Cameca ims-1270 equipped with a cryo-sample-stage of Hokkaido University was specially prepared for the O and H isotopic measurements. The cryo-sample-stage (Techno. I. S. Corp.) was cooled down to c.a. -190 C using liquid nitrogen at which the aqueous fluid in inclusions was frozen. We excavated the salt crystal surfaces to expose the frozen fluids using a 15 keV Cs+ beam and measured negative secondary ions. The secondary ions from deep craters of approximately 10 m in depth emitted stably but the intensities changed gradually during measurement cycles because of shifting states of charge compensation, resulting in rather poor reproducibility of multiple measurements of standard fluid

  8. Sampling and chemical analysis in environmental samples around Nuclear Power Plants and some environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yong Woo; Han, Man Jung; Cho, Seong Won; Cho, Hong Jun; Oh, Hyeon Kyun; Lee, Jeong Min; Chang, Jae Sook [KORTIC, Taejon (Korea, Republic of)

    2002-12-15

    Twelve kinds of environmental samples such as soil, seawater, underground water, etc. around Nuclear Power Plants(NPPs) were collected. Tritium chemical analysis was tried for the samples of rain water, pine-needle, air, seawater, underground water, chinese cabbage, a grain of rice and milk sampled around NPPs, and surface seawater and rain water sampled over the country. Strontium in the soil that sere sampled at 60 point of district in Korea were analyzed. Tritium were sampled at 60 point of district in Korea were analyzed. Tritium were analyzed in 21 samples of surface seawater around the Korea peninsular that were supplied from KFRDI(National Fisheries Research and Development Institute). Sampling and chemical analysis environmental samples around Kori, Woolsung, Youngkwang, Wooljin Npps and Taeduk science town for tritium and strontium analysis was managed according to plans. Succeed to KINS after all samples were tried.

  9. Applications of Liquid-Phase Microextraction in the Sample Preparation of Environmental Solid Samples

    Directory of Open Access Journals (Sweden)

    Helena Prosen

    2014-05-01

    Full Text Available Solvent extraction remains one of the fundamental sample preparation techniques in the analysis of environmental solid samples, but organic solvents are toxic and environmentally harmful, therefore one of the possible greening directions is its miniaturization. The present review covers the relevant research from the field of application of microextraction to the sample preparation of environmental solid samples (soil, sediments, sewage sludge, dust etc. published in the last decade. Several innovative liquid-phase microextraction (LPME techniques that have emerged recently have also been applied as an aid in sample preparation of these samples: single-drop microextraction (SDME, hollow fiber-liquid phase microextraction (HF-LPME, dispersive liquid-liquid microextraction (DLLME. Besides the common organic solvents, surfactants and ionic liquids are also used. However, these techniques have to be combined with another technique to release the analytes from the solid sample into an aqueous solution. In the present review, the published methods were categorized into three groups: LPME in combination with a conventional solvent extraction; LPME in combination with an environmentally friendly extraction; LPME without previous extraction. The applicability of these approaches to the sample preparation for the determination of pollutants in solid environmental samples is discussed, with emphasis on their strengths, weak points and environmental impact.

  10. Applications of liquid-phase microextraction in the sample preparation of environmental solid samples.

    Science.gov (United States)

    Prosen, Helena

    2014-05-23

    Solvent extraction remains one of the fundamental sample preparation techniques in the analysis of environmental solid samples, but organic solvents are toxic and environmentally harmful, therefore one of the possible greening directions is its miniaturization. The present review covers the relevant research from the field of application of microextraction to the sample preparation of environmental solid samples (soil, sediments, sewage sludge, dust etc.) published in the last decade. Several innovative liquid-phase microextraction (LPME) techniques that have emerged recently have also been applied as an aid in sample preparation of these samples: single-drop microextraction (SDME), hollow fiber-liquid phase microextraction (HF-LPME), dispersive liquid-liquid microextraction (DLLME). Besides the common organic solvents, surfactants and ionic liquids are also used. However, these techniques have to be combined with another technique to release the analytes from the solid sample into an aqueous solution. In the present review, the published methods were categorized into three groups: LPME in combination with a conventional solvent extraction; LPME in combination with an environmentally friendly extraction; LPME without previous extraction. The applicability of these approaches to the sample preparation for the determination of pollutants in solid environmental samples is discussed, with emphasis on their strengths, weak points and environmental impact.

  11. Recovery of Picloram and 2,4-Dichlorophenoxyacetic Acid from Aqueous Samples by Reversed-Phase Solid-Phase Extraction

    Science.gov (United States)

    Martha J.M. Wells; Jerry L. Michael

    1987-01-01

    Extensive preparation of samples before chromatographic analysis is usually the most time-consuming process in the determination of many organic compounds in environmental matrices. In the past, removal of some organic from aqueous solution was commonly done by liquid/liquid extraction. However, the introduction of stable, covalently bonded reversed-phase sorbents now...

  12. Multi-elemental analysis of aqueous geological samples by inductively coupled plasma-optical emission spectrometry

    Science.gov (United States)

    Todorov, Todor I.; Wolf, Ruth E.; Adams, Monique

    2014-01-01

    Typically, 27 major, minor, and trace elements are determined in natural waters, acid mine drainage, extraction fluids, and leachates of geological and environmental samples by inductively coupled plasma-optical emission spectrometry (ICP-OES). At the discretion of the analyst, additional elements may be determined after suitable method modifications and performance data are established. Samples are preserved in 1–2 percent nitric acid (HNO3) at sample collection or as soon as possible after collection. The aqueous samples are aspirated into the ICP-OES discharge, where the elemental emission signals are measured simultaneously for 27 elements. Calibration is performed with a series of matrix-matched, multi-element solution standards.

  13. Assessment of environmental control technology for coal conversion aqueous wastes

    Energy Technology Data Exchange (ETDEWEB)

    Klein, J.A.; Barker, R.E.

    1978-07-01

    A hydrocarbonization process has been studied to assess environmental control technology for coal conversion wastewaters. Fifteen major wastewater streams were identified; 2 present serious environmental problems not routinely encountered in industry. These are the hydrocarbonization condensate and the ash sluicing waste from the gasifier. The hydrocarbonization product water is high in phenolics, ammonia, cyanide, thiocyanate, and other sulfur compounds. This stream will present a significant wastewater treatment problem unless the stream can be recycled internally. The gasifier-ash sluicing water will probably be similar to ash sluicing water from coal-fired power generating plants. However, the large quantity of toxic trace elements may be more easily dissolved from ash produced at the lower-temperature and reducing conditions encountered in gasification. A number of cleanup technologies relevant to the cleanup of coal conversion aqueous effluents have ben assessed for their adaptability to the specific pollutants found in coal hydrocarbonization wastewater. A summary of these processes lists the potential applicability, economics, raw material requirements, process compatibility, operating conditions, state of development, environmental problems, energy requirements, and availability of each. Indications are that almost any level of removal can be achieved if one is willing to pay the cost. The optimum amount of cleanup will require much future interaction between industry, environmental control technology developers, human and environmental effects assessors, and federal effluent regulations administrators.

  14. Diagnostic herd sensitivity using environmental samples

    DEFF Research Database (Denmark)

    Vigre, Håkan; Josefsen, Mathilde Hartmann; Seyfarth, Anne Mette

    be assessed. In this abstract we present an approach to evaluate the sensitivity of environmental samples used for herd classification. This is illustrated using results from samples for isolation of methicillin resistant Staphylococcus aureus (MRSA) in 48 pig herds that had previously been tested positive...... in the probability of isolating MRSA in the environmental samples by increasing within-herd prevalence. This relationship was strongest for dust where the sensitivity increased from 25% at 1% infected pigs, to 35% at a 25% infected pigs. The air sampling was more sensitive to detect infected herds irrespectively...

  15. Hanford Site Environmental Surveillance Master Sampling Schedule

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2002-01-16

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs. The document contains the CY 2002 schedules for the routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project.

  16. Isotope dilution analysis of environmental samples

    International Nuclear Information System (INIS)

    Tolgyessy, J.; Lesny, J.; Korenova, Z.; Klas, J.; Klehr, E.H.

    1986-01-01

    Isotope dilution analysis has been used for the determination of several trace elements - especially metals - in a variety of environmental samples, including aerosols, water, soils, biological materials and geological materials. Variations of the basic concept include classical IDA, substoichiometric IDA, and more recently, sub-superequivalence IDA. Each variation has its advantages and limitations. A periodic chart has been used to identify those elements which have been measured in environmental samples using one or more of these methods. (author)

  17. Hanford site environmental surveillance master sampling schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1998-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5400.1 open-quotes General Environmental Protection Program,close quotes and DOE Order 5400.5, open-quotes Radiation Protection of the Public and the Environment.close quotes The sampling methods are described in the Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office, DOE/RL91-50, Rev. 2, U.S. Department of Energy, Richland, Washington. This document contains the 1998 schedules for routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. Each section of this document describes the planned sampling schedule for a specific media (air, surface water, biota, soil and vegetation, sediment, and external radiation). Each section includes the sample location, sample type, and analyses to be performed on the sample. In some cases, samples are scheduled on a rotating basis and may not be planned for 1998 in which case the anticipated year for collection is provided. In addition, a map is included for each media showing sample locations

  18. Hanford Site Environmental Surveillance Master Sampling Schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    1999-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5400.1, ''General Environmental protection Program,'' and DOE Order 5400.5, ''Radiation Protection of the Public and the Environment.'' The sampling methods are described in the Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office, DOE/RL-91-50, Rev.2, U.S. Department of Energy, Richland, Washington. This document contains the CY1999 schedules for the routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. Each section includes the sampling location, sample type, and analyses to be performed on the sample. In some cases, samples are scheduled on a rotating basis and may not be collected in 1999 in which case the anticipated year for collection is provided. In addition, a map is included for each media showing approximate sampling locations

  19. Methods in environmental sampling for radionuclides

    International Nuclear Information System (INIS)

    Ragaini, R.C.

    1976-01-01

    This paper reviews methods of environmental sampling for radionuclides around operational and preoperational nuclear power plants. We examine in detail the implications of the established radiation standards and their effect on sampling procedures. Transport mechanisms of radionuclides in liquid effluent, and the deposition of airborne radionuclides onto soil and vegetation are discussed. We evaluate water- and soil-sampling procedures. The Lawrence Livermore Laboratory program of terrestrial gamma-ray surveys at preoperational nuclear power plants is described

  20. Hanford Site Environmental Surveillance Master Sampling Schedule

    International Nuclear Information System (INIS)

    Bisping, L.E.

    2000-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 5400.1, General Environmental Protection Program: and DOE Order 5400.5, Radiation Protection of the Public and the Environment. The sampling design is described in the Operations Office, Environmental Monitoring Plan, United States Department of Energy, Richland DOE/RL-91-50, Rev.2, U.S. Department of Energy, Richland, Washington. This document contains the CY 2000 schedules for the routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. Each section includes sampling locations, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis and may not be collected in 2000 in which case the anticipated year for collection is provided. In addition, a map showing approximate sampling locations is included for each media scheduled for collection

  1. Sampling for silver nanoparticles in aqueous media using a rotating disk electrode: evidence for selective sampling of silver nanoparticles in the presence of ionic silver.

    Science.gov (United States)

    Steinberg, Spencer; Hodge, Vernon; Schumacher, Brian; Sovocool, Wayne

    2017-03-01

    Amendment of a carbon paste electrode consisting of graphite and Nujol®, with a variety of organic and inorganic materials, allows direct adsorption of silver nanoparticles (AgNPs) from aqueous solution in either open or close circuit modes. The adsorbed AgNPs are detected by stripping voltammetry. Detection limits of less than 1 ppb Ag are achievable with a rotating disk system. More than one silver peak was apparent in many of the stripping voltammograms. The appearance of multiple peaks could be due to different species of silver formed upon stripping or variation in the state of aggregation or size of nanoparticles. With most of these packing materials, dissolved Ag + was also extracted from aqueous solution, but, with a packing material made with Fe(II,III) oxide nanoparticles, only AgNPs were extracted. Therefore, it is the best candidate for determination of metallic AgNPs in aqueous environmental samples without interference from Ag + .

  2. Practical reporting times for environmental samples

    International Nuclear Information System (INIS)

    Bayne, C.K.; Schmoyer, D.D.; Jenkins, R.A.

    1993-02-01

    Preanalytical holding times for environmental samples are specified because chemical and physical characteristics may change between sampling and chemical analysis. For example, the Federal Register prescribes a preanalytical holding time of 14 days for volatile organic compounds in soil stored at 4 degrees C. The American Society for Testing Materials (ASTM) uses a more technical definition that the preanalytical holding time is the day when the analyte concentration for an environmental sample falls below the lower 99% confidence interval on the analyte concentration at day zero. This study reviews various holding time definitions and suggest a new preanalytical holding time approach using acceptable error rates for measuring an environmental analyte. This practical reporting time (PRT) approach has been applied to nineteen volatile organic compounds and four explosives in three environmental soil samples. A PRT nomograph of error rates has been developed to estimate the consequences of missing a preanalytical holding time. This nomograph can be applied to a large class of analytes with concentrations that decay linearly or exponentially with time regardless of sample matrices and storage conditions

  3. Practical reporting times for environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Bayne, C.K.; Schmoyer, D.D.; Jenkins, R.A.

    1993-02-01

    Preanalytical holding times for environmental samples are specified because chemical and physical characteristics may change between sampling and chemical analysis. For example, the Federal Register prescribes a preanalytical holding time of 14 days for volatile organic compounds in soil stored at 4{degrees}C. The American Society for Testing Materials (ASTM) uses a more technical definition that the preanalytical holding time is the day when the analyte concentration for an environmental sample falls below the lower 99% confidence interval on the analyte concentration at day zero. This study reviews various holding time definitions and suggest a new preanalytical holding time approach using acceptable error rates for measuring an environmental analyte. This practical reporting time (PRT) approach has been applied to nineteen volatile organic compounds and four explosives in three environmental soil samples. A PRT nomograph of error rates has been developed to estimate the consequences of missing a preanalytical holding time. This nomograph can be applied to a large class of analytes with concentrations that decay linearly or exponentially with time regardless of sample matrices and storage conditions.

  4. Analysis procedure for americium in environmental samples

    International Nuclear Information System (INIS)

    Holloway, R.W.; Hayes, D.W.

    1982-01-01

    Several methods for the analysis of 241 Am in environmental samples were evaluated and a preferred method was selected. This method was modified and used to determine the 241 Am content in sediments, biota, and water. The advantages and limitations of the method are discussed. The method is also suitable for 244 Cm analysis

  5. RAPID DETERMINATION OF RA-226 IN ENVIRONMENTAL SAMPLES

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, S.

    2012-01-03

    A new rapid method for the determination of {sup 226}Ra in environmental samples has been developed at the Savannah River Site Environmental Lab (Aiken, SC, USA) that can be used for emergency response or routine sample analyses. The need for rapid analyses in the event of a Radiological Dispersive Device or Improvised Nuclear Device event is well-known. In addition, the recent accident at Fukushima Nuclear Power Plant in March, 2011 reinforces the need to have rapid analyses for radionuclides in environmental samples in the event of a nuclear accident. {sup 226}Ra (T1/2 = 1,620 years) is one of the most toxic of the long-lived alpha-emitters present in the environment due to its long life and its tendency to concentrate in bones, which increases the internal radiation dose of individuals. The new method to determine {sup 226}Ra in environmental samples utilizes a rapid sodium hydroxide fusion method for solid samples, calcium carbonate precipitation to preconcentrate Ra, and rapid column separation steps to remove interferences. The column separation process uses cation exchange resin to remove large amounts of calcium, Sr Resin to remove barium and Ln Resin as a final purification step to remove {sup 225}Ac and potential interferences. The purified {sup 226}Ra sample test sources are prepared using barium sulfate microprecipitation in the presence of isopropanol for counting by alpha spectrometry. The method showed good chemical recoveries and effective removal of interferences. The determination of {sup 226}Ra in environmental samples can be performed in less than 16 h for vegetation, concrete, brick, soil, and air filter samples with excellent quality for emergency or routine analyses. The sample preparation work takes less than 6 h. {sup 225}Ra (T1/2 = 14.9 day) tracer is used and the {sup 225}Ra progeny {sup 217}At is used to determine chemical yield via alpha spectrometry. The rapid fusion technique is a rugged sample digestion method that ensures that any

  6. Nuclear techniques for analysis of environmental samples

    International Nuclear Information System (INIS)

    1986-12-01

    The main purposes of this meeting were to establish the state-of-the-art in the field, to identify new research and development that is required to provide an adequate framework for analysis of environmental samples and to assess needs and possibilities for international cooperation in problem areas. This technical report was prepared on the subject based on the contributions made by the participants. A separate abstract was prepared for each of the 9 papers

  7. Strontium-90 determination in environmental samples

    International Nuclear Information System (INIS)

    Figueira, Rubens Cesar Lopes.

    1994-01-01

    The study to establish radiochemical methods for strontium-90 analysis in environmental samples, such as water, seawater, fish, marina sediment, soil and air filters is presented. The analyses were divided in the following steps: leaching of strontium-90 from fish, marine sediment, soil and air filter samples with nitric acid and hydrogen peroxide; strontium-90 preconcentration in seawater by using sodium carbonate and from other matrices sulfuric acid; magnesium separation in seawater matrix with ammonium chloride; separation of interferents elements, time to reach radioactive equilibrium between strontium-90 and yttrium-90; separation of strontium-90 from yttrium-90, by precipitation with hydroxide and conversion to oxalate, and beta counting of yttrium-90 in Geiger-Mueller detector with low background radiation and high counting efficiency. The methodology developed for strontium-90 analysis in environmental samples, presented a strontium-90 recuperation of about 90%, for water, 66% for seawater and higher than 80% for fish bones and muscles, marine sediment, soil and air filter samples. (author). 78 refs., 6 figs., 21 tabs

  8. Recent Results of the Investigation of a Microfluidic Sampling Chip and Sampling System for Hot Cell Aqueous Processing Streams

    Energy Technology Data Exchange (ETDEWEB)

    Julia Tripp; Jack Law; Tara Smith

    2013-10-01

    A Fuel Cycle Research and Development project has investigated an innovative sampling method that could evolve into the next generation sampling and analysis system for metallic elements present in aqueous processing streams. Initially sampling technologies were evaluated and microfluidics sampling chip technology was selected and tested. A conceptual design for a fully automated microcapillary-based system was completed and a robotic automated sampling system was fabricated. The mechanical and sampling operation of the completed sampling system was investigated. In addition, the production of a less expensive, mass produced sampling chip was investigated to avoid chip reuse thus increasing sampling reproducibility/accuracy. The microfluidic-based robotic sampling system’s mechanical elements were tested to ensure analytical reproducibility and the optimum robotic handling of microfluidic sampling chips.

  9. Intrepretation of work area and environmental sampling

    International Nuclear Information System (INIS)

    Ritter, P.D.; Alvarez, J.L.; Novick, V.J.

    1985-01-01

    Meaningful interpretation of widely variable airborne contamination measurements is a difficult problem. Exposure limits, action levels, etc., are rigid interpretations of inherently variable environmental or workplace conditions, and are useful for control and regulatory compliance evaluations. Such limits force actions to reduce contamination, but have limited usefulness as benchmarks for evaluating isolated or nonrepresentative measurements. This paper deals with interpretation of exposure based on nonrepresentative sampling. The use of hard limits for interpreting measurements of legal record simplifies judgment during cursory audits; more aggressive questioning of the validity of these records may effectively invalidate them in a courtroom situation

  10. Osmium in environmental samples from Northeast Sweden

    International Nuclear Information System (INIS)

    Rodushkin, Ilia; Engstroem, Emma; Soerlin, Dieke; Ponter, Christer; Baxter, Douglas C.

    2007-01-01

    Osmium (Os) concentrations and 187 Os/ 188 Os isotope abundance ratios are presented for sedimentary materials, soils, humus, plants, mushrooms, mosses and lichens collected in the vicinity of the town of Lulea, Northeast Sweden, the data for biological specimens being the first reported. Contributions from sampling and varying exposure time to the observed environmental variability were evaluated. Sedimentary materials (from both fresh and brackish water) are most elevated in radiogenic 187 Os, followed by inorganic soil horizons, mushrooms and humus. The Os isotopic compositions of plants, mosses and lichens are much less radiogenic, with mean 187 Os/ 188 Os lying within a relatively narrow 0.3-0.6 range. Significant temporal variations in Os concentrations and isotopic compositions of plant samples are attributed to integrative uptake of airborne Os with non-radiogenic composition. Measured Os concentrations in biological matrices increase in the order: small shrub leaves (blueberry and lingonberry) ≤ spruce needles ≤ mushrooms ≤ tree leaves ≤ pine needles 4 ) in the environment. Though the Os content of samples from Northeast Sweden does not differ significantly from matrix-matched international reference materials (not certified for Os) of abiotic origin, the estimates of gaseous OsO 4 concentrations are roughly an order of magnitude higher than have been reported for particle-bound Os in other studies. The pronounced spatial variations between relatively closely situated sites in mean 187 Os/ 188 Os ratios for samples of the same species (presumably with the same dominating uptake mechanism) point to the presence of different local Os sources. This study therefore demonstrates that emissions of Os from automobile catalytic converters are not the only source of contemporary environmental contamination

  11. Osmium in environmental samples from Northeast Sweden

    Energy Technology Data Exchange (ETDEWEB)

    Rodushkin, Ilia [Division of Applied Geology, Lulea University of Technology, S-971 87 Lulea (Sweden); ALS Laboratory Group, ALS Analytica AB, Aurorum 10, S-977 75 Lulea (Sweden)], E-mail: ilia.rodushkin@alsglobal.com; Engstroem, Emma [Division of Applied Geology, Lulea University of Technology, S-971 87 Lulea (Sweden); Soerlin, Dieke; Ponter, Christer; Baxter, Douglas C. [ALS Laboratory Group, ALS Analytica AB, Aurorum 10, S-977 75 Lulea (Sweden)

    2007-11-01

    Osmium (Os) concentrations and {sup 187}Os/{sup 188}Os isotope abundance ratios are presented for sedimentary materials, soils, humus, plants, mushrooms, mosses and lichens collected in the vicinity of the town of Lulea, Northeast Sweden, the data for biological specimens being the first reported. Contributions from sampling and varying exposure time to the observed environmental variability were evaluated. Sedimentary materials (from both fresh and brackish water) are most elevated in radiogenic {sup 187}Os, followed by inorganic soil horizons, mushrooms and humus. The Os isotopic compositions of plants, mosses and lichens are much less radiogenic, with mean {sup 187}Os/{sup 188}Os lying within a relatively narrow 0.3-0.6 range. Significant temporal variations in Os concentrations and isotopic compositions of plant samples are attributed to integrative uptake of airborne Os with non-radiogenic composition. Measured Os concentrations in biological matrices increase in the order: small shrub leaves (blueberry and lingonberry) {<=} spruce needles {<=} mushrooms {<=} tree leaves {<=} pine needles < mosses << lichens. The concentrations found in three different species of plant were used to provide the first estimates of gaseous osmium tetroxide (OsO{sub 4}) in the environment. Though the Os content of samples from Northeast Sweden does not differ significantly from matrix-matched international reference materials (not certified for Os) of abiotic origin, the estimates of gaseous OsO{sub 4} concentrations are roughly an order of magnitude higher than have been reported for particle-bound Os in other studies. The pronounced spatial variations between relatively closely situated sites in mean {sup 187}Os/{sup 188}Os ratios for samples of the same species (presumably with the same dominating uptake mechanism) point to the presence of different local Os sources. This study therefore demonstrates that emissions of Os from automobile catalytic converters are not the only

  12. Fallout Concentration Various Environmental Samples in Indonesia

    International Nuclear Information System (INIS)

    Sutarman

    2001-01-01

    The testing of nuclear weapons have been carried out by the advanced countries, such as United States, Russian Federation, United Kingdom, France, China, India and Pakistan, since about 1945 until 1998. Nuclear weapons tests were conducted at various locations, on and above the earth's surface or underground or on and under the ocean's surface. Nuclear explosions caused the radionuclides of fission product, such as 131 l, 89 Sr, 90 Sr, 134 Cs, 137 Cs, and 239 Pu released to the atmospheric layer. In the atmospheric layer, the long-lived radionuclides, i.e, 90 Sr dan 137 Cs will be distributed into the environment as the fallout radionuclides, and deposited in the various environmental samples (soil, water, and biota). In general, at several locations in Indonesia the 90 Sr and 137 Cs in the various environmental samples still can be detected. The data of measurement results of 90 Sr and 137 Cs concentrations were generally lower than that from some countries in the northern hemisphere. (author)

  13. Separation and Preconcentration of Trace Amounts of Nickel from Aqueous Samples

    Directory of Open Access Journals (Sweden)

    Reyhaneh Rahnama

    2018-05-01

    Full Text Available In this paper, a new method for preconcentration and measurement of trace amounts of nickel in aqueous samples by magnetic solid phase extraction (MSPE via magnetic carbon nanotubes (Mag-CNTs was developed. In order to increase selectivity, α-Furildioxime was used as chelating agent. In order to do extraction, optimum amount of ligand was added to the nickel sample and pH was set on 9, then 7 ml. of adsorbent was added and stirred for 15 minutes. After that, aqueous phase and adsorbent were separated by a strong magnet. Finally, the absorption was measured via flame atomic absorption spectrometry by analyte elution from the absorbent with an appropriate solution. Parameters affecting the extraction and preconcentration of nickel were investigated and optimized. Under optimum conditions, the calibration curve was linear in concentration range from 2.5 to 375 µg L-1 and the detection limit was 0.8 µg L-1 of nickel. The method was applied for determination of nickel in aqueous samples. The relative efficiency values of nickel measurement in aqueous samples were from 98.7% to 102.1%.  Results indicated that Mag-CNTs can be used as an effective and inexpensive absorbent for preconcentration and extraction of nickel from actual samples.

  14. Photonic Molecularly Imprinted Polymer Film for the Detection of Testosterone in Aqueous Samples

    Directory of Open Access Journals (Sweden)

    Abbas J. Kadhem

    2018-03-01

    Full Text Available The detection of testosterone in aqueous solutions is a difficult task due to the low concentration levels that are relevant in environmental and physiological samples. Current analytical methods are expensive and/or complex. To address this issue, we fabricated a molecularly imprinted polymer (MIP photonic film for the detection of testosterone in water. The films were obtained using colloidal crystals as templates for the pore morphology. Monodispersed silica particles with an average diameter 330 nm were used to obtain the colloidal crystal by vertical deposition. A solution of acrylic acid with testosterone as the imprinted template was infiltrated in the colloidal crystal and polymerized via bulk polymerization; the particles were then removed by acid etching and the testosterone eluted by a suitable solvent. The material was characterized by FTIR, swelling experiments and microscopy; MIPs were investigated by equilibrium rebinding, kinetics and reuse experiments. The results showed that the MIPs exhibited selectivity to the template, a 30-min equilibration time and stability after at least six cycles of use and regeneration. After incubation, the reflectance spectra of the films showed a shift of the Bragg diffraction peak that correlated with testosterone concentration in the 5–100 ppb range.

  15. Measurements of plutonium in environmental samples

    International Nuclear Information System (INIS)

    D'Alberti, F.; Risposi, L.

    1996-01-01

    Within the activities connected with the start up of the PETRA Laboratory (Processo per l'Estrazione di Terre Rare ed Attinidi, i.e. process for extraction of rare earths and actinides), the Radiation Protection Unit of the J.R.C.-Ispra has carried out a well planned set of experimental measurements aimed at evaluating the zero point of the isotopes of plutonium in environmental samples by alfa spectrometry. After the International Moratorium in 1963, no release of plutonium has occurred in the environment apart from the burn up of SNAP 9A satellite in April 1964. Since then the plutonium concentration in air and in fallout samples has been continuously decreasing requiring, therefore, optimization of both instrumentation and experimental measurement procedures in order to obtain better sensibilities. In this work, the experimental methodology followed at the J.R.C.-Ispra for measurements of plutonium concentration in air, deposition and soil is described and the plutonium behaviour in these samples is reported and discussed starting from 1961

  16. Separation Techniques for Quantification of Radionuclides in Environmental Samples

    Directory of Open Access Journals (Sweden)

    Dusan Galanda

    2009-01-01

    Full Text Available The reliable and quantitative measurement of radionuclides is important in order to determine environmental quality and radiation safety, and to monitor regulatory compliance. We examined soil samples from Podunajske Biskupice, near the city of Bratislava in the Slovak Republic, for the presence of several natural (238U, 232Th, 40K and anthropogenic (137Cs, 90Sr, 239Pu, 240Pu, 241Am radionuclides. The area is adjacent to a refinery and hazardous waste processing center, as well as the municipal incinerator plant, and so might possess an unusually high level of ecotoxic metals. We found that the levels of both naturally occurring and anthropogenic radionuclides fell within the expected ranges, indicating that these facilities pose no radiological threat to the local environment. During the course of our analysis, we modified existing techniques in order to allow us to handle the unusually large and complex samples that were needed to determine the levels of 239Pu, 240Pu, and 241Am activity. We also rated three commercial techniques for the separation of 90Sr from aqueous solutions and found that two of them, AnaLig Sr-01 and Empore Extraction Disks, were suitable for the quantitative and reliable separation of 90Sr, while the third, Sr-Spec Resin, was less so. The main criterion in evaluating these methods was the chemical recovery of 90Sr, which was less than we had expected. We also considered speed of separation and additional steps needed to prepare the sample for separation.

  17. Determination of ambient ethanol concentrations in aqueous environmental matrixes by two independent analyses.

    Science.gov (United States)

    Kieber, R J; Guy, A L; Roebuck, J A; Carroll, A L; Mead, R N; Jones, S B; Giubbina, F F; Campos, M L A M; Willey, J D; Avery, G B

    2013-06-18

    A new method for the determination of ethanol in aqueous environmental matrixes at nanomolar concentrations is presented and compared to an existing method that has been optimized for low-level alcohol determinations. The new analysis is based upon oxidation of ethanol by the enzyme alcohol oxidase obtained from the yeast Hansenula sp. which quantitatively produces acetaldehyde after reaction for 120 min at 40 °C and pH 9.0. The acetaldehyde reacts with 2,4-dinitrophenylhydrazine forming a hydrazone that is separated from interfering substances and quantified by high-performance liquid chromatography (HPLC) with UV detection at 370 nm. Comparison of initial acetaldehyde concentration with that after enzymatic oxidation yields the ethanol concentration with a corresponding detection limit of 10 nM. Analytical results were verified by intercomparison with a completely independent technique utilizing a solid-phase microextraction (SPME) Carboxen/PDMS SPME fiber. A 12 mL aqueous phase sample was heated at 50 °C for 10 min prior to loading onto the SPME fiber. Extraction of ethanol was performed by introducing the fiber into the headspace above a pH 4.4 buffered sample containing 30% NaCl for 20 min. Samples were agitated during heating and extraction by magnetic stirring at a rate of 750 rpm. The fiber was thermally desorbed for 1 min at 230 °C in the injection port of a gas chromatograph equipped with a flame ionization detector (FID) set at 250 °C. The resulting ethanol detection limit is 19 nM. Results of an intercomparison study between the enzymatic and SPME analyses produced a trend line with a slope of unity demonstrating that methods produced statistically equivalent ethanol concentrations in several natural waters including rainwater, fresh surface waters, and sediment pore waters.

  18. Unexpected toxicity to aquatic organisms of some aqueous bisphenol A samples treated by advanced oxidation processes.

    Science.gov (United States)

    Tišler, Tatjana; Erjavec, Boštjan; Kaplan, Renata; Şenilă, Marin; Pintar, Albin

    2015-01-01

    In this study, photocatalytic and catalytic wet-air oxidation (CWAO) processes were used to examine removal efficiency of bisphenol A from aqueous samples over several titanate nanotube-based catalysts. Unexpected toxicity of bisphenol A (BPA) samples treated by means of the CWAO process to some tested species was determined. In addition, the CWAO effluent was recycled five- or 10-fold in order to increase the number of interactions between the liquid phase and catalyst. Consequently, the inductively coupled plasma mass spectrometry (ICP-MS) analysis indicated higher concentrations of some toxic metals like chromium, nickel, molybdenum, silver, and zinc in the recycled samples in comparison to both the single-pass sample and the photocatalytically treated solution. The highest toxicity of five- and 10-fold recycled solutions in the CWAO process was observed in water fleas, which could be correlated to high concentrations of chromium, nickel, and silver detected in tested samples. The obtained results clearly demonstrated that aqueous samples treated by means of advanced oxidation processes should always be analyzed using (i) chemical analyses to assess removal of BPA and total organic carbon from treated aqueous samples, as well as (ii) a battery of aquatic organisms from different taxonomic groups to determine possible toxicity.

  19. Pre-concentration of nitrosamines from aqueous samples by SPE and MEKC

    OpenAIRE

    Sanches Filho, Pedro Jose; Zanin, Kelen Daiane; Caramão, Elina Bastos; Garcia, Ronaldo Caramão; Rios, Angel; Valcárcel, Miguel

    2003-01-01

    This paper describes the development of a methodology for solid phase extraction (SPE) and pre-concentration of nitrosamines from aqueous samples using granular activated charcoal as stationary phase. micelar electrokinetic capillary Chromatography (MEKC) was used for the separation and identification of the nitrosamines in the extracts. Using a sample with 50 µg l-1 of each nitrosamines standards (dimethylnitrosamine, DMN; diethylnitrosamine, DEN; N-nitrosopyrrolidine, NPYR; N-nitrosop...

  20. Self-attenuation of gamma rays during radioactivity concentration analysis of environmental samples

    International Nuclear Information System (INIS)

    Watson, D.; Dharmasiri, J.; Akber, R.

    2001-01-01

    Gamma spectroscopy using HPGe detector systems is a readily used technique for routine analysis of radioactivity in environmental samples. The systems are generally calibrated using standards of known radioactivity and composition. Radioactivity in environmental samples is generally distributed in the bulk of the material. When a sample of finite thickness is analysed through gamma spectroscopy, a proportion of the gamma rays emitted from the sample is either stopped or scattered from the sample material itself. These processes of self-absorption and self-attenuation depend upon the physical and elemental composition of the sample and the energy of the gamma radiation. Since environmental samples vary in composition, instrument calibration using a fixed matrix composition may not be valid for a diversity of samples. We selected and analysed five sample matrices to investigate the influence of self-absorption and self-attenuation in environmental samples. Our selection consisted of bentonite and kaolin representing clay, quartz representing silica, ash representing prepared biota, and analytical grade MnO 2 representing a co-precipitant used for extractive radioactivity from aqueous samples. Our findings show that within 5% of uncertainty the silica based standards can be used to cover the environmental samples of varying clay (silica content). The detection efficiency for ash and MnO 2 could be different particularly in the 30 - 100 keV energy range. The differences in sample behaviour can be explained on the basis of atomic number, mass number and density

  1. Environmental Sampling, Monitoring and Site Assessment Data

    Data.gov (United States)

    U.S. Environmental Protection Agency — Quality Data Asset includes all current and historical data on environmental quality with regard to the presence of radiological contamination of all kinds regulated...

  2. Speciation and detection of arsenic in aqueous samples: A review of recent progress in non-atomic spectrometric methods

    Energy Technology Data Exchange (ETDEWEB)

    Ma, Jian [State Key Laboratory of Marine Environmental Science, College of the Environment and Ecology, Xiamen University, Xiamen 361102 (China); Department of Chemistry and Biochemistry, University of Texas, 700 Planetarium Place, Arlington, TX 76019 (United States); Sengupta, Mrinal K. [Department of Chemistry and Biochemistry, University of Texas, 700 Planetarium Place, Arlington, TX 76019 (United States); Thermo Fisher Scientific, Dionex Products, 445 Lakeside Drive, Sunnyvale, CA, 94085 (United States); Yuan, Dongxing [State Key Laboratory of Marine Environmental Science, College of the Environment and Ecology, Xiamen University, Xiamen 361102 (China); Dasgupta, Purnendu K., E-mail: Dasgupta@uta.edu [Department of Chemistry and Biochemistry, University of Texas, 700 Planetarium Place, Arlington, TX 76019 (United States)

    2014-06-01

    Highlights: • Compilation of principal official documents and major review articles, including the toxicology and chemistry of As. • Review of non-atomic spectrometric methods for speciation and detection of arsenic in aqueous samples (2005–2013) of the performance of field-usable methods. - Abstract: Inorganic arsenic (As) displays extreme toxicity and is a class A human carcinogen. It is of interest to both analytical chemists and environmental scientists. Facile and sensitive determination of As and knowledge of the speciation of forms of As in aqueous samples are vitally important. Nearly every nation has relevant official regulations on permissible limits of drinking water As content. The size of the literature on As is therefore formidable. The heart of this review consists of two tables: one is a compilation of principal official documents and major review articles, including the toxicology and chemistry of As. This includes comprehensive official compendia on As speciation, sample treatment, recommended procedures for the determination of As in specific sample matrices with specific analytical instrument(s), procedures for multi-element (including As) speciation and analysis, and prior comprehensive reviews on arsenic analysis. The second table focuses on the recent literature (2005–2013, the coverage for 2013 is incomplete) on As measurement in aqueous matrices. Recent As speciation and analysis methods based on spectrometric and electrochemical methods, inductively coupled plasma-mass spectrometry, neutron activation analysis and biosensors are summarized. We have deliberately excluded atomic optical spectrometric techniques (atomic absorption, atomic fluorescence, inductively coupled plasma-optical emission spectrometry) not because they are not important (in fact the majority of arsenic determinations are possibly carried out by one of these techniques) but because these methods are sufficiently mature and little meaningful innovation has been

  3. Some analytical aspects about determination of Sr89 and Sr90 in environmental samples

    International Nuclear Information System (INIS)

    Gasco, C.; Alvarez Garcia, A.

    1988-01-01

    Some problems about determination of Sr 89 and Sr 90 in environmental samples have been studied. The main difficulties are due to the wide range in the concentration of their components and the contents of chemical and radiochemical interferent elements. The behaviour of strontium on ion exchange resin has been described by some experiments in various media: aqueous media, calcium concentration and matrix variable. The differences of alkaline-earth nitrate and carbonate solubilities have been analyzed in nitric acid. The chemical recovery in environmental samples has been determined. (Author)

  4. Prediction of aqueous and nonaqueous solubilities of chemicals with environmental interest by UNIFAC

    International Nuclear Information System (INIS)

    Kan, A.T.; Tomson, M.B.

    1995-01-01

    This paper is to investigate the accuracy and precision of predicting the aqueous and non-aqueous solubilities of a vast number of chemicals with significant environmental roles using the latest version of UNIFAC group interaction parameters. A few critical measurements to test specific UNIFAC calculations of nonaqueous solubilities are also reported. The chemicals included in the calculation have aqueous solubilities that span eleven orders of magnitude. Good agreement was observed between the UNIFAC predicted and literature reported aqueous solubilities for eleven groups of compounds. Similarly, UNIFAC successfully predicts the co-solvency of PCB in methanol/water solutions. The error between predicted and literature reported aqueous solubilities was larger for three groups of chemicals: long chain alkanes, phthalates, and chlorinated alkenes. The average absolute error in UNIFAC precision of aqueous solubilities is about 0.5 log units, but the average absolute error is only about 0.2 log units for chlorinated aromatic compounds in organic solvents. The application of UNIFAC approach to predict the fate of hydrocarbons and PCBs in soil column flushing, cosolvency and in natural gas pipeline liquids will be discussed

  5. The search for and analysis of direct samples of early Solar System aqueous fluids.

    Science.gov (United States)

    Zolensky, Michael E; Bodnar, Robert J; Yurimoto, Hisayoshi; Itoh, Shoichi; Fries, Marc; Steele, Andrew; Chan, Queenie H-S; Tsuchiyama, Akira; Kebukawa, Yoko; Ito, Motoo

    2017-05-28

    We describe the current state of the search for direct, surviving samples of early, inner Solar System fluids-fluid inclusions in meteorites. Meteoritic aqueous fluid inclusions are not rare, but they are very tiny and their characterization is at the state of the art for most analytical techniques. Meteoritic fluid inclusions offer us a unique opportunity to study early Solar System brines in the laboratory. Inclusion-by-inclusion analyses of the trapped fluids in carefully selected samples will, in the immediate future, provide us detailed information on the evolution of fluids as they interacted with anhydrous solid materials. Thus, real data can replace calculated fluid compositions in thermochemical calculations of the evolution of water and aqueous reactions in comets, asteroids, moons and the terrestrial planets.This article is part of the themed issue 'The origin, history and role of water in the evolution of the inner Solar System'. © 2017 The Author(s).

  6. Hanford Site Environmental Surveillance Master Sampling Schedule, January 2001

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2001-01-08

    This document contains the CY 2001 schedules for the routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. Each section includes sampling locations, sample types, and analyses to be performed.

  7. Environmentally persistent free radicals (EPFRs)-2. Are free hydroxyl radicals generated in aqueous solutions?

    Science.gov (United States)

    Khachatryan, Lavrent; Dellinger, Barry

    2011-11-01

    A chemical spin trap, 5,5-dimethyl-1-pyrroline-N-oxide (DMPO), in conjunction with electron paramagnetic resonance (EPR) spectroscopy was employed to measure the production of hydroxyl radical (·OH) in aqueous suspensions of 5% Cu(II)O/silica (3.9% Cu) particles containing environmentally persistent free radicals (EPFRs) of 2-monochlorophenol (2-MCP). The results indicate: (1) a significant differences in accumulated DMPO-OH adducts between EPFR containing particles and non-EPFR control samples, (2) a strong correlation between the concentration of DMPO-OH adducts and EPFRs per gram of particles, and (3) a slow, constant growth of DMPO-OH concentration over a period of days in solution containing 50 μg/mL EPFRs particles + DMPO (150 mM) + reagent balanced by 200 μL phosphate buffered (pH = 7.4) saline. However, failure to form secondary radicals using standard scavengers, such as ethanol, dimethylsulfoxide, sodium formate, and sodium azide, suggests free hydroxyl radicals may not have been generated in solution. This suggests surface-bound, rather than free, hydroxyl radicals were generated by a surface catalyzed-redox cycle involving both the EPFRs and Cu(II)O. Toxicological studies clearly indicate these bound free radicals promote various types of cardiovascular and pulmonary disease normally attributed to unbound free radicals; however, the exact chemical mechanism deserves further study in light of the implication of formation of bound, rather than free, hydroxyl radicals.

  8. Radiation Target Area Sample Environmental Chamber (RTASEC), Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Payload Systems Inc. proposes the Radiation Target Area Sample Environmental Chamber (RTASEC) as an innovative approach enabling radiobiologists to investigate the...

  9. Method for monitoring mineralization of /sup 14/C-labeled compounds in aqueous samples

    Energy Technology Data Exchange (ETDEWEB)

    Fedorak, P.M.; Foght, J.M.; Westlake, D.W.S. (Alberta Univ., Edmonton (Canada). Dept. of Microbiology)

    1982-01-01

    Previously reported laboratory methods for measuring the rate of /sup 14/CO/sub 2/ release from an aqueous sample require a series of replicate growth flasks. At chosen times, some of these are sacrificed in order to quantitate the /sup 14/CO/sub 2/ released. The method presented here requires only one culture flask containing 200 ml of sample with labeled substrate, and one control-replacement flask containing 200 ml of sterile sample with labeled substrate. At each sampling time, 1/40th of the liquid and headspace gas is removed from the modified 500 ml Erlenmeyer culture flask for /sup 14/CO/sub 2/ recovery. This method was used to study the mineralization of labeled amino acids, starch, n-hexadecane and anthracene by micro-organisms in river water, and of n-hexadecane and n-hexadecanoic acid by microorganisms in sewage effluent.

  10. Measurement of Cadmium Ion in the Presence of Metal-Binding Biopolymers in Aqueous Sample

    Directory of Open Access Journals (Sweden)

    Jian Pu

    2013-01-01

    Full Text Available In aqueous environment, water-soluble polymers are effectively used to separate free metal ions from metal-polymer complexes. The feasibilities of four different analytical techniques, cadmium ion-selective electrode, dialysis sack, chelate disk cartridge, and ultrafiltration, in distinguishing biopolymer-bound and nonbound cadmium in aqueous samples were investigated. And two different biopolymers were used, including bovine serum albumin (BSA and biopolymer solution extracted from cultivated activated sludge (ASBP. The ISE method requires relatively large amount of sample and contaminates sample during the pretreatment. After the long reaction time of dialysis, the equilibrium of cadmium in the dialysis sack would be shifted. Due to the sample nature, chelate disk cartridge could not filter within recommended time, which makes it unavailable for biopolymer use. Ultrafiltration method would not experience the difficulties mentioned above. Ultrafiltration method measuring both weakly and strongly bound cadmium was included in nominally biopolymer-cadmium complex. It had significant correlation with the Ion-selective electrode (ISE method (R2=0.989 for BSA, 0.985 for ASBP.

  11. Applications of Liquid-Phase Microextraction in the Sample Preparation of Environmental Solid Samples

    OpenAIRE

    Helena Prosen

    2014-01-01

    Solvent extraction remains one of the fundamental sample preparation techniques in the analysis of environmental solid samples, but organic solvents are toxic and environmentally harmful, therefore one of the possible greening directions is its miniaturization. The present review covers the relevant research from the field of application of microextraction to the sample preparation of environmental solid samples (soil, sediments, sewage sludge, dust etc.) published in the last decade. Several...

  12. Multi-analyte approach for the determination of ng L-1 levels of steroid hormones in unidentified aqueous samples

    International Nuclear Information System (INIS)

    Noppe, H.; Verheyden, K.; Gillis, W.; Courtheyn, D.; Vanthemsche, P.; De Brabander, H.F.

    2007-01-01

    Since the 1970s, many analytical methods for the detection of illegal growth promoters, such as thyreostats, anabolics, β-agonists and corticosteroids have been developed for a wide range of matrices of animal origin, including meat, fat, organ tissue, urine and faeces. The aim of this study was to develop an analytical method for the determination of ng L -1 levels of estrogens, gestagens, androgens (EGAs) and corticosteroids in aqueous preparations (i.e. drinking water, drinking water supplements), commercially available on the 'black' market. For this, extraction was performed with Bakerbond C 18 speedisk, a technique commonly used in environmental analysis. After fractionation, four fractions were collected using a methanol:water gradient program. Gas chromatography coupled to electron impact multiple mass spectrometry (GC-EI-MS 2 ) screening for the EGAs was carried out on the derivatized extracts. For the detection of corticosteroids, gas chromatography coupled to negative chemical ionization mass spectrometry (GC-NCI-MS) was used after oxidation of the extracts. Confirmation was done by liquid chromatography coupled to electrospray ionization multiple mass spectrometry (LC-ESI-MS 2 ). The combined use of GC and LC coupled to MS enabled the identification and quantification of anabolics and corticosteroids at the low ng L -1 level. This study demonstrated the occurrence of both androgens and corticosteroids in different commercial aqueous samples

  13. "Reactive" optical sensor for Hg2+and its application in environmental aqueous media and biological systems.

    Science.gov (United States)

    Chen, Zhi; Chen, Jiayun; Pan, Dong; Li, Hongwei; Yao, Yunhui; Lyu, Zu; Yang, Liting; Ma, Li-Jun

    2017-03-01

    A new rhodamine B-based "reactive" optical sensor (1) for Hg 2+ was synthesized. Sensor 1 shows a unique colorimetric and fluorescent "turn-on" selectivity to Hg 2+ over 14 other metal ions with a hypersensitivity (detection limits are 27.6 nM (5.5 ppb) and 6.9 nM (1.4 ppb), respectively) in neutral buffer solution. To test its applicability in the environment, sensor 1 was applied to quantify and visualize low levels of Hg 2+ in tap water and river water samples. The results indicate sensor 1 is a highly sensitive fluorescent sensor for Hg 2+ with a detection limit of 1.7 ppb in tap water and river water. Moreover, sensor 1 is a convenient visualizing sensor for low levels of Hg 2+ (0.1 ppm) in water environment (from colorless to light pink). In addition, sensor 1 shows good potential as a fluorescent visualizing sensor for Hg 2+ in fetal bovine serum and living 293T cells. The results indicate that sensor 1 shows good potential as a highly sensitive sensor for the detection of Hg 2+ in environmental and biological samples. Graphical Abstract A new rhodamine B-based "reactive" optical sensor (1) for Hg 2+ was synthesized. 1 shows a unique colorimetric and fluorescent "turn-on" selectivity to Hg 2+ over 14 other metal ions with a hypersensitivity in water environment. And it is a convenient visualizing probe for low levels of Hg 2+ in environment aqueous media, fetal bovine serum and living 293T cells.

  14. Method for analysis of polar volatile trace components in aqueous samples by gas chromatography.

    Science.gov (United States)

    Pettersson, Johan; Roeraade, Johan

    2005-05-15

    A new method has been developed for direct analysis of volatile polar trace compounds in aqueous samples by gas chromatography. Water samples are injected onto a short packed precolumn containing anhydrous lithium chloride. A capillary column is coupled in series with the prefractionation column for final separation of the analytes. The enrichment principle of the salt precolumn is reverse to the principles employed in conventional methods such as SPE or SPME in which a sorbent or adsorbent is utilized to trap or concentrate the analytes. Such methods are not efficient for highly polar compounds. In the LiCl precolumn concept, the water matrix is strongly retained on the hygroscopic salt, whereas polar as well as nonpolar volatile organic compounds show very low retention and are eluted ahead of the water. After transfer of the analytes to the capillary column, the retained bulk water is removed by backflushing the precolumn at elevated temperature. For direct injections of 120 microL of aqueous samples, the combined time for injection and preseparation is only 3.5 min. With this procedure, direct repetitive automated analyses of highly volatile polar compounds such as methanol or tetrahydrofuran can be performed, and a limit of quantification in the low parts-per-billion region utilizing a flame ionization detector is demonstrated.

  15. Trace-level mercury ion (Hg2+) analysis in aqueous sample based on solid-phase extraction followed by microfluidic immunoassay.

    Science.gov (United States)

    Date, Yasumoto; Aota, Arata; Terakado, Shingo; Sasaki, Kazuhiro; Matsumoto, Norio; Watanabe, Yoshitomo; Matsue, Tomokazu; Ohmura, Naoya

    2013-01-02

    Mercury is considered the most important heavy-metal pollutant, because of the likelihood of bioaccumulation and toxicity. Monitoring widespread ionic mercury (Hg(2+)) contamination requires high-throughput and cost-effective methods to screen large numbers of environmental samples. In this study, we developed a simple and sensitive analysis for Hg(2+) in environmental aqueous samples by combining a microfluidic immunoassay and solid-phase extraction (SPE). Using a microfluidic platform, an ultrasensitive Hg(2+) immunoassay, which yields results within only 10 min and with a lower detection limit (LOD) of 0.13 μg/L, was developed. To allow application of the developed immunoassay to actual environmental aqueous samples, we developed an ion-exchange resin (IER)-based SPE for selective Hg(2+) extraction from an ion mixture. When using optimized SPE conditions, followed by the microfluidic immunoassay, the LOD of the assay was 0.83 μg/L, which satisfied the guideline values for drinking water suggested by the United States Environmental Protection Agency (USEPA) (2 μg/L; total mercury), and the World Health Organisation (WHO) (6 μg/L; inorganic mercury). Actual water samples, including tap water, mineral water, and river water, which had been spiked with trace levels of Hg(2+), were well-analyzed by SPE, followed by microfluidic Hg(2+) immunoassay, and the results agreed with those obtained from reduction vaporizing-atomic adsorption spectroscopy.

  16. Sampling quality assurance guidance in support of EM environmental sampling and analysis activities

    International Nuclear Information System (INIS)

    1994-05-01

    This document introduces quality assurance guidance pertaining to the design and implementation of sampling procedures and processes for collecting environmental data for DOE's Office of EM (Environmental Restoration and Waste Management)

  17. DOE methods for evaluating environmental and waste management samples.

    Energy Technology Data Exchange (ETDEWEB)

    Goheen, S C; McCulloch, M; Thomas, B L; Riley, R G; Sklarew, D S; Mong, G M; Fadeff, S K [eds.; Pacific Northwest Lab., Richland, WA (United States)

    1994-04-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) provides applicable methods in use by. the US Department of Energy (DOE) laboratories for sampling and analyzing constituents of waste and environmental samples. The development of DOE Methods is supported by the Laboratory Management Division (LMD) of the DOE. This document contains chapters and methods that are proposed for use in evaluating components of DOE environmental and waste management samples. DOE Methods is a resource intended to support sampling and analytical activities that will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the US Environmental Protection Agency (EPA), or others.

  18. DOE methods for evaluating environmental and waste management samples

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K.

    1993-03-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) provides applicable methods in use by. the US Department of Energy (DOE) laboratories for sampling and analyzing constituents of waste and environmental samples. The development of DOE Methods is supported by the Laboratory Management Division (LMD) of the DOE. This document contains chapters and methods that are proposed for use in evaluating components of DOE environmental and waste management samples. DOE Methods is a resource intended to support sampling and analytical activities that will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the US Environmental Protection Agency (EPA), or others

  19. Analysis of mercury in environmental samples

    International Nuclear Information System (INIS)

    Schoester, F.S.

    1992-01-01

    The possibility to determine mercury in sub-ppm levels in biological samples has been studied through neutron activation analysis , using as standards aliquots of mercury nitrate solution, deposited on treated cellulose with thio acetamide and ammonia. Sample and standards were irradiated simultaneously in quartz ampoules during 8 hours at a flux of 5 x 10 13 n/cm 2 s and were counted in a hyper pure germanium detector after 4 weeks of decay. Corrections were made for the interference of 75 Se in the 279 keV photopeak used in the determination. The results obtained for the reference materials IAEA-H-8(horse kidney), IAEA-M A-A2(fish flesh) and IAEA-M A-A-1(cope pod homogenate) were (0.91±0.07), (0.56±0.02) and (0.17±0.02) ppm, versus certified values of (0.91±0.08), (0.47±0.02) and (0.28±0.01) ppm respectively. (EMR). 54 refs., 8 app

  20. New trends in sample preparation techniques for environmental analysis.

    Science.gov (United States)

    Ribeiro, Cláudia; Ribeiro, Ana Rita; Maia, Alexandra S; Gonçalves, Virgínia M F; Tiritan, Maria Elizabeth

    2014-01-01

    Environmental samples include a wide variety of complex matrices, with low concentrations of analytes and presence of several interferences. Sample preparation is a critical step and the main source of uncertainties in the analysis of environmental samples, and it is usually laborious, high cost, time consuming, and polluting. In this context, there is increasing interest in developing faster, cost-effective, and environmentally friendly sample preparation techniques. Recently, new methods have been developed and optimized in order to miniaturize extraction steps, to reduce solvent consumption or become solventless, and to automate systems. This review attempts to present an overview of the fundamentals, procedure, and application of the most recently developed sample preparation techniques for the extraction, cleanup, and concentration of organic pollutants from environmental samples. These techniques include: solid phase microextraction, on-line solid phase extraction, microextraction by packed sorbent, dispersive liquid-liquid microextraction, and QuEChERS (Quick, Easy, Cheap, Effective, Rugged and Safe).

  1. Organically bound tritium analysis in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Baglan, N. [CEA/DAM/DIF, Arpajon (France); Kim, S.B. [AECL, Chalk River Laboratories, Chalk River, ON (Canada); Cossonnet, C. [IRSN/PRP-ENV/STEME/LMRE, Orsay (France); Croudace, I.W.; Warwick, P.E. [GAU-Radioanalytical, University of Southampton, Southampton (United Kingdom); Fournier, M. [IRSN/DG/DMQ, Fontenay-aux-Roses (France); Galeriu, D. [IFIN-HH, Horia-Hulubei, Inst. Phys. and Nucl. Eng., Bucharest (Romania); Momoshima, N. [Kyushu University, Radioisotope Ctr., Fukuoka (Japan); Ansoborlo, E. [CEA/DEN/DRCP/CETAMA, Bagnols-sur-Ceze (France)

    2015-03-15

    Organically bound tritium (OBT) has become of increased interest within the last decade, with a focus on its behaviour and also its analysis, which are important to assess tritium distribution in the environment. In contrast, there are no certified reference materials and no standard analytical method through the international organization related to OBT. In order to resolve this issue, an OBT international working group was created in May 2012. Over 20 labs from around the world participated and submitted their results for the first intercomparison exercise results on potato (Sep 2013). The samples, specially-prepared potatoes, were provided in March 2013 to each participant. Technical information and results from this first exercise are discussed here for all the labs which have realised the five replicates necessary to allow a reliable statistical treatment. The results are encouraging as the increased number of participating labs did not degrade the observed dispersion of the results for a similar activity level. Therefore, the results do not seem to depend on the analytical procedure used. From this work an optimised procedure can start to be developed to deal with OBT analysis and will guide subsequent planned OBT trials by the international group.

  2. Ash contents of foodstuff samples in environmental radioactivity analysis

    International Nuclear Information System (INIS)

    Oikawa, Shinji; Ohta, Hiroshi; Hayano, Kazuhiko; Nonaka, Nobuhiro

    2004-01-01

    Statistical data of the ash content in various environmental samples obtained from an environmental radioactivity survey project commissioned by the Japanese government of Science and Technology Agency (at present Ministry of Education, Culture, Sports, Sciences and Technology) during the past 10 years are expressed for establishing a standard of ash content in environmental samples based on radioactivity analysis. The ash content for some kinds of environmental samples such as dietary food, milk, Japanese radish, spinach, fish, green tea and potato was reviewed in the light of statistical and stochastic viewpoints. For all of the samples reviewed in this paper, the coefficient of variation varied from 4.7% for milk to 36.3% for cabbage. Dietary food and milk samples were reviewed more than 1900 and 1400 samples, respectively. Especially, ash content of dietary food depended mainly on the dietary culture reflected on the period. However it showed an almost invariant distribution within 18.7% of coefficient of variation during the past 10 years. Pretreatment of environmental samples especially ashing processes are important from the viewpoint on environmental radioactivity analysis, which is one of the especial fields in analytical chemistry. Statistical reviewed data obtained in this paper may be useful for sample preparation. (author)

  3. Liquid Phase Micro-Extraction of Linear Alkylbenzene Sulfonate Anionic Surfactants in Aqueous Samples

    Directory of Open Access Journals (Sweden)

    Jan Åke Jönsson

    2011-10-01

    Full Text Available Hollow fiber liquid phase micro-extraction (LPME of linear alkylbenzene sulfonates (LAS from aqueous samples was studied. Ion pair extraction of C10, C11, C12 and C13 homologues was facilitated with trihexylamine as ion-pairing agent, using di-n-hexylether as solvent for the supported liquid membrane (SLM. Effects of extraction time, acceptor buffer concentration, stirring speed, sample volume, NaCl and humic acids were studied. At 10–50 µg L−1 linear R2-coefficients were 0.99 for C10 and C11 and 0.96 for C12. RSD was typically ~15%. Three observations were especially made. Firstly, LPME for these analytes was unusually slow with maximum enrichment observed after 15–24 h (depending on sample volume. Secondly, the enrichment depended on LAS sample concentration with 35–150 times enrichment below ~150 µg L−1 and 1850–4400 times enrichment at 1 mg L−1. Thirdly, lower homologues were enriched more than higher homologues at low sample concentrations, with reversed conditions at higher concentrations. These observations may be due to the fact that LAS and the amine counter ion themselves influence the mass transfer at the water-SLM interface. The observations on LPME of LAS may aid in LPME application to other compounds with surfactant properties or in surfactant enhanced membrane extraction of other compounds.

  4. Preparation of Magnetic Sorbent with Surface Modified by C18for Removal of Selected Organic Pollutants from Aqueous Samples

    Science.gov (United States)

    Kuráň, Pavel; Pilnaj, Dominik; Ciencialová, Lucie; Pšenička, Martin

    2017-12-01

    Magnetic sorbents have great potential in environmental applications due to their simple synthesis and separation in magnetic field, usability in heterogeneous systems and low toxicity. Possible syntheses, surface modifications and characteristics were described by Li et al 2013. This type of solid-phase extraction is being successfully used in various fields as health care, microbiology, biotechnologies or sample preconcentration in analytical chemistry. In this preliminary study we report on the preparation and application of magnetically separable sorbent with surface modified by C18 alkyl chain for purification of water contaminated by environmentally hazardous organic compounds. Magnetic cores were co-precipitated from Fe2+ and Fe3+ chlorides in alkalic aqueous solution. Surface of synthetized Fe3O4 was modified with SiO2 by tetraethylorthosilicate to assure physico-chemical stability. Furthermore, Fe3O4/SiO2 complex has been treated by C18 functional group, which provides good affinity towards hydrophobic substances in water. Efficiency of sorption under various conditions has been examined on benzene, toluene, ethylbenzene and xylenes (BTEX), compounds found in petroleum products which contaminate air, soil and groundwater near of store tanks. Sorption kinetics was followed by gas chromatography with mass spectrometry. The preliminary sorption kinetics data and efficiency of BTEX removal point at the possible application of prepared magnetic sorbent for BTEX removal, especially for ethylbenzene and xylenes.

  5. Predictive Sampling of Rare Conformational Events in Aqueous Solution: Designing a Generalized Orthogonal Space Tempering Method.

    Science.gov (United States)

    Lu, Chao; Li, Xubin; Wu, Dongsheng; Zheng, Lianqing; Yang, Wei

    2016-01-12

    In aqueous solution, solute conformational transitions are governed by intimate interplays of the fluctuations of solute-solute, solute-water, and water-water interactions. To promote molecular fluctuations to enhance sampling of essential conformational changes, a common strategy is to construct an expanded Hamiltonian through a series of Hamiltonian perturbations and thereby broaden the distribution of certain interactions of focus. Due to a lack of active sampling of configuration response to Hamiltonian transitions, it is challenging for common expanded Hamiltonian methods to robustly explore solvent mediated rare conformational events. The orthogonal space sampling (OSS) scheme, as exemplified by the orthogonal space random walk and orthogonal space tempering methods, provides a general framework for synchronous acceleration of slow configuration responses. To more effectively sample conformational transitions in aqueous solution, in this work, we devised a generalized orthogonal space tempering (gOST) algorithm. Specifically, in the Hamiltonian perturbation part, a solvent-accessible-surface-area-dependent term is introduced to implicitly perturb near-solute water-water fluctuations; more importantly in the orthogonal space response part, the generalized force order parameter is generalized as a two-dimension order parameter set, in which essential solute-solvent and solute-solute components are separately treated. The gOST algorithm is evaluated through a molecular dynamics simulation study on the explicitly solvated deca-alanine (Ala10) peptide. On the basis of a fully automated sampling protocol, the gOST simulation enabled repetitive folding and unfolding of the solvated peptide within a single continuous trajectory and allowed for detailed constructions of Ala10 folding/unfolding free energy surfaces. The gOST result reveals that solvent cooperative fluctuations play a pivotal role in Ala10 folding/unfolding transitions. In addition, our assessment

  6. Adsorption of diazinon from aqueous solutions onto an activated carbon sample produced in Iran

    Directory of Open Access Journals (Sweden)

    Zeynab Akbarlou

    2017-05-01

    Full Text Available Background: Considering the severe health and environmental hazards caused by the entry of diazinon toxin into water resources, its removal is very important. Given the high costs of imported adsorbents, this research attempted to evaluate, for the first time, the efficiency of Iranian activated carbon in removing diazinon from aqueous solutions. Methods: In this batch experimental study, the effects of contact time (5-90 minutes, adsorbent concentration (0.5-30 g/L, initial concentration of diazinon (5-50 mg/L, and pH (3-10 on the adsorption of diazinon onto the activated carbon were evaluated. Concentrations of diazinon were measured using a high pressure liquid chromatography (HPLC instrument. The specific surface area of the adsorbent was determined by BET and BJH methods. The experimental adsorption data was analyzed using Langmuir and Freundlich isotherm models. Pseudo first-order and pseudo second-order kinetics models were employed to determine kinetics. Moreover, data was analyzed using SPSS version 19, and Pearson correlation and analysis of variance (ANOVA tests were performed at a significance level of 0.05. Results: The optimum contact time, sorbent dose, and pH were 30 minutes, 10 g/L, and 5, respectively. The adsorbent could adsorb diazinon with a removal efficiency of 92.5% under optimum conditions (initial concentration: 20 mg/L. The experimental data was better described by the pseudo-second order kinetic and Langmuir isotherm. A maximum adsorption capacity of 71.4 mg/g was calculated by the Langmuir isotherm model. Conclusion: With respect to the high adsorption capacity of Iranian activated carbon, this sorbent can be considered an efficient adsorbent for the removal of diazinon from aqueous solutions.

  7. Experiences performed at the C:R: Saluggia of ENEA in low-level determination of plutonium in biological and environmental samples

    International Nuclear Information System (INIS)

    Spezzano, Pasquale

    1997-10-01

    This report describes some experiences performed at the Research Center Saluggia of ENEA concerning low-level determination of plutonium in biological and environmental samples, with discussions of practical analytical problems. The main characteristics and properties of plutonium with emphasis to aqueous solutions chemistry and environmental behaviour are also reported

  8. Development of novel and sensitive methods for the determination of sulfide in aqueous samples by hydrogen sulfide generation-inductively coupled plasma-atomic emission spectroscopy.

    Science.gov (United States)

    Colon, M; Todolí, J L; Hidalgo, M; Iglesias, M

    2008-02-25

    Two new, simple and accurate methods for the determination of sulfide (S(2-)) at low levels (microgL(-1)) in aqueous samples were developed. The generation of hydrogen sulfide (H(2)S) took place in a coil where sulfide reacted with hydrochloric acid. The resulting H(2)S was then introduced as a vapor into an inductively coupled plasma-atomic emission spectrometer (ICP-AES) and sulfur emission intensity was measured at 180.669nm. In comparison to when aqueous sulfide was introduced, the introduction of sulfur as H(2)S enhanced the sulfur signal emission. By setting a gas separator at the end of the reaction coil, reduced sulfur species in the form of H(2)S were removed from the water matrix, thus, interferences could be avoided. Alternatively, the gas separator was replaced by a nebulizer/spray chamber combination to introduce the sample matrix and reagents into the plasma. This methodology allowed the determination of both sulfide and sulfate in aqueous samples. For both methods the linear response was found to range from 5microgL(-1) to 25mgL(-1) of sulfide. Detection limits of 5microgL(-1) and 6microgL(-1) were obtained with and without the gas separator, respectively. These new methods were evaluated by comparison to the standard potentiometric method and were successfully applied to the analysis of reduced sulfur species in environmental waters.

  9. Aqueous extracts of Mozambican plants as alternative and environmentally safe acid-base indicators.

    Science.gov (United States)

    Macuvele, Domingos Lusitaneo Pier; Sithole, Gerre Zebedias Samo; Cesca, Karina; Macuvele, Suzana Lília Pinare; Matsinhe, Jonas Valente

    2016-06-01

    Indicators are substances that change color as the pH of the medium. Many of these substances are dyes of synthetic origin. The mulala plant (Euclea natalensis), which roots are commonly used by rural communities for their oral hygiene, and roseira (Hibiscus rosa-sinensis), an ornamental plant, are abundant in Mozambique. Currently, synthetic acid-base indicators are most commonly used but have environmental implications and, on the other hand, are expensive products, so the demand for natural indicators started. This study investigated the applicability of aqueous extracts of H. rosa-sinensis and E. natalensis as acid-base indicators. Ground on this work, the extracts can be used as acid-base indicators. On the basis of the absorption spectroscopy in both the UV-Vis region and previous studies, it was possible to preliminarily pinpoint anthocyanins and naphthoquinones as responsible for the shifting of colors depending on the pH range of aqueous extracts of H. rosa-sinensis and E. natalensis. These natural indicators are easily accessible, inexpensive, easy to extract, environmentally safe, and locally available.

  10. Aqueous two-phase extraction as a platform in the biomanufacturing industry: economical and environmental sustainability.

    Science.gov (United States)

    Rosa, P A J; Azevedo, A M; Sommerfeld, S; Bäcker, W; Aires-Barros, M R

    2011-01-01

    The biotech industry is, nowadays, facing unparalleled challenges due to the enhanced demand for biotechnology-based human therapeutic products, such as monoclonal antibodies (mAbs). This has led companies to improve substantially their upstream processes, with the yield of monoclonals increasing to titers never seen before. The downstream processes have, however, been overlooked, leading to a production bottleneck. Although chromatography remains the workhorse of most purification processes, several limitations, such as low capacity, scale-related packing problems, low chemical and proteolytic stability and resins' high cost, have arisen. Aqueous two-phase extraction (ATPE) has been successfully revisited as a valuable alternative for the capture of antibodies. One of the important remaining questions for this technology to be adopted by the biotech industries is, now, how it compares to the currently established platforms in terms of costs and environmental impact. In this report, the economical and environmental sustainability of the aqueous two-phase extraction process is evaluated and compared to the currently established protein A affinity chromatography. Accordingly, the ATPE process was shown to be considerably advantageous in terms of process economics, especially when processing high titer cell culture supernatants. This alternative process is able to purify continuously the same amount of mAbs reducing the annual operating costs from 14.4 to 8.5 million (US$/kg) when cell culture supernatants with mAb titers higher than 2.5 g/L are processed. Copyright © 2011 Elsevier Inc. All rights reserved.

  11. Gamma spectrometric analyses of environmental samples at PINSTECH

    International Nuclear Information System (INIS)

    Faruq, M.U.; Parveen, N.; Ahmed, B.; Aziz, A.

    1979-01-01

    Gamma spectrometric analyses of air and other environmental samples from PINSTECH were carried out. Air particulate samples were analyzed by a Ge(Li) detector on a computer-based multichannel analyzer. Other environmental samples were analyzed by a Na(T1) scintillation detector spectrometer and a multichannel analyzer with manual analysis. Concentration of radionuclides in the media was determined and the sources of their production were identified. Age of the fall out was estimated from the ratios of the fission products. (authors)

  12. Environmental Technology (Laboratory Analysis and Environmental Sampling) Curriculum Development Project. Final Report.

    Science.gov (United States)

    Hinojosa, Oscar V.; Guillen, Alfonso

    A project assessed the need and developed a curriculum for environmental technology (laboratory analysis and environmental sampling) in the emerging high technology centered around environmental safety and health in Texas. Initial data were collected through interviews by telephone and in person and through onsite visits. Additional data was…

  13. Radiological analyses of Marshall Islands environmental samples, 1974--1976

    International Nuclear Information System (INIS)

    Greenhouse, N.A.; Miltenberger, R.P.; Cua, F.T.

    1977-01-01

    Results are reported from the radiological analysis of environmental samples collected in the Marshall Islands during 1974 through 1976. Most of the samples were collected on or near the Bikini Atoll and included plants, soil, fish, catchment water, and sediments, with emphasis on local marine and terrestrial food items. Data are presented from γ spectral analysis and the content of 90 Sr and transuranic elements in the samples

  14. Radiological analyses of Marshall Islands environmental samples, 1974--1976

    Energy Technology Data Exchange (ETDEWEB)

    Greenhouse, N.A.; Miltenberger, R.P.; Cua, F.T.

    1977-12-12

    Results are reported from the radiological analysis of environmental samples collected in the Marshall Islands during 1974 through 1976. Most of the samples were collected on or near the Bikini Atoll and included plants, soil, fish, catchment water, and sediments, with emphasis on local marine and terrestrial food items. Data are presented from ..gamma.. spectral analysis and the content of /sup 90/Sr and transuranic elements in the samples.

  15. Forward flux sampling calculation of homogeneous nucleation rates from aqueous NaCl solutions

    Science.gov (United States)

    Jiang, Hao; Haji-Akbari, Amir; Debenedetti, Pablo G.; Panagiotopoulos, Athanassios Z.

    2018-01-01

    We used molecular dynamics simulations and the path sampling technique known as forward flux sampling to study homogeneous nucleation of NaCl crystals from supersaturated aqueous solutions at 298 K and 1 bar. Nucleation rates were obtained for a range of salt concentrations for the Joung-Cheatham NaCl force field combined with the Extended Simple Point Charge (SPC/E) water model. The calculated nucleation rates are significantly lower than the available experimental measurements. The estimates for the nucleation rates in this work do not rely on classical nucleation theory, but the pathways observed in the simulations suggest that the nucleation process is better described by classical nucleation theory than an alternative interpretation based on Ostwald's step rule, in contrast to some prior simulations of related models. In addition to the size of NaCl nucleus, we find that the crystallinity of a nascent cluster plays an important role in the nucleation process. Nuclei with high crystallinity were found to have higher growth probability and longer lifetimes, possibly because they are less exposed to hydration water.

  16. Screening of IAEA environmental samples for fissile material content

    International Nuclear Information System (INIS)

    Hembree, Doyle M. Jr.; Carter, Joel A.; Devault, Gerald L.; Whitaker, J. Michael; Glasgow, David

    2001-01-01

    Full text: Analysis of environmental samples for the International Atomic Energy Agency (IAEA) Strengthened Safeguards Systems program requires that stringent measures be taken to control contamination. To facilitate contamination control, it is extremely useful to have some estimate of the fissile content of a given sample prior to beginning sample preparation and analysis. This is particularly true for laboratories that employ clean rooms during sample preparation. A review of the analytical results for samples submitted between January 1, 1999 and September 1, 2000 revealed that the total uranium content values ranged from 0.2 to greater than 500,000 ng/sample. Poor estimates of the uranium or plutonium content in the samples have caused some of the laboratories in the IAEA Network of Analytical Laboratories (NWAL) to experience clean laboratory contamination, sample cross contamination, and non-ideal uranium spike additions. This has led to significant increases in analysis costs (e.g., recertification of clean rooms after removing contamination, and rerunning samples) and degradation in data quality. A number of methods have been proposed for screening environmental samples for fissile material content, including gamma spectrometry, x-ray fluorescence, kinetic phosphorimetry (KPA), and inductively coupled plasma-mass spectrometry (ICP-MS). Gamma spectrometry and x-ray fluorescence are suitable for screening samples with microgram or greater quantities of uranium. ICP-MS and KPA are used successfully in some DOE NWAL laboratories to screen environmental samples. A neutron activation analysis (NAA) method that offers numerous advantages over other screening techniques for environmental samples has recently been proposed. Fissile materials such as 239 Pu and 235 U can be made to undergo fission in the intense neutron field to which they are exposed during neutron activation analysis (NAA). Some of the fission products emit neutrons referred to as 'delayed

  17. Development of analytical techniques for safeguards environmental samples at JAEA

    International Nuclear Information System (INIS)

    Sakurai, Satoshi; Magara, Masaaki; Usuda, Shigekazu; Watanabe, Kazuo; Esaka, Fumitaka; Hirayama, Fumio; Lee, Chi-Gyu; Yasuda, Kenichiro; Inagawa, Jun; Suzuki, Daisuke; Iguchi, Kazunari; Kokubu, Yoko S.; Miyamoto, Yutaka; Ohzu, Akira

    2007-01-01

    JAEA has been developing, under the auspices of the Ministry of Education, Culture, Sports, Science and Technology of Japan, analytical techniques for ultra-trace amounts of nuclear materials in environmental samples in order to contribute to the strengthened safeguards system. Development of essential techniques for bulk and particle analysis, as well as screening, of the environmental swipe samples has been established as ultra-trace analytical methods of uranium and plutonium. In January 2003, JAEA was qualified, including its quality control system, as a member of the JAEA network analytical laboratories for environmental samples. Since 2004, JAEA has conducted the analysis of domestic and the IAEA samples, through which JAEA's analytical capability has been verified and improved. In parallel, advanced techniques have been developed in order to expand the applicability to the samples of various elemental composition and impurities and to improve analytical accuracy and efficiency. This paper summarizes the trace of the technical development in environmental sample analysis at JAEA, and refers to recent trends of research and development in this field. (author)

  18. Determination of technetium-99 in environmental samples: A review

    DEFF Research Database (Denmark)

    Shi, Keliang; Hou, Xiaolin; Roos, Per

    2012-01-01

    . This article summarizes and compares recently reported chemical separation procedures and measurement methods for determination of 99Tc. Due to the extremely low concentration of 99Tc in environmental samples, the sample preparation, pre-concentration, chemical separation and purification for removal...... research due to the high technetium solubility in seawater as TcO4−. A number of analytical methods, using chemical separation combined with radiometric and mass spectrometric measurement techniques, have been developed over the past decades for determination of 99Tc in different environmental samples......Due to the lack of a stable technetium isotope, and the high mobility and long half-life, 99Tc is considered to be one of the most important radionuclides in safety assessment of environmental radioactivity as well as nuclear waste management. 99Tc is also an important tracer for oceanographic...

  19. Serological and polymerase chain reaction-based analysis of aqueous humour samples in patients with AIDS and necrotizing retinitis

    NARCIS (Netherlands)

    Verbraak, F. D.; Galema, M.; van den Horn, G. H.; Bruinenberg, M.; Luyendijk, L.; Danner, S. A.; Kijlstra, A.

    1996-01-01

    To evaluate the measurement of intraocular antibody production and detection of DNA by the polymerase chain reaction (PCR) for diagnosis of the causative microorganism in patients with AIDS and necrotizing retinitis. Paired serum and aqueous humour samples obtained from 28 patients with AIDS and

  20. Sample preparation of environmental samples using benzene synthesis followed by high-performance LSC

    International Nuclear Information System (INIS)

    Filippis, S. De; Noakes, J.E.

    1991-01-01

    Liquid scintillation counting (LSC) techniques have been widely employed as the detection method for determining environmental levels of tritium and 14 C. Since anthropogenic and nonanthropogenic inputs to the environment are a concern, sampling the environment surrounding a nuclear power facility or fuel reprocessing operation requires the collection of many different sample types, including agriculture products, water, biota, aquatic life, soil, and vegetation. These sample types are not suitable for the direct detection of tritium of 14 C for liquid scintillation techniques. Each sample type must be initially prepared in order to obtain the carbon or hydrogen component of interest and present this in a chemical form that is compatible with common chemicals used in scintillation counting applications. Converting the sample of interest to chemically pure benzene as a sample preparation technique has been widely accepted for processing samples for radiocarbon age-dating applications. The synthesized benzene is composed of the carbon or hydrogen atoms from the original sample and is ideal as a solvent for LSC with excellent photo-optical properties. Benzene synthesis followed by low-background scintillation counting can be applied to the preparation and measurement of environmental samples yielding good detection sensitivities, high radionuclide counting efficiency, and shorter preparation time. The method of benzene synthesis provides a unique approach to the preparation of a wide variety of environmental sample types using similar chemistry for all samples

  1. River-induced flow dynamics in long-screen wells and impact on aqueous samples.

    Science.gov (United States)

    Vermeul, Vince R; McKinley, James P; Newcomer, Darrell R; Mackley, Robert D; Zachara, J M

    2011-01-01

    Previously published field investigations and modeling studies have demonstrated the potential for sample bias associated with vertical wellbore flow in conventional monitoring wells constructed with long-screened intervals. This article builds on the existing body of literature by (1) demonstrating the utility of continuous (i.e., hourly measurements for ∼1 month) ambient wellbore flow monitoring and (2) presenting results from a field experiment where relatively large wellbore flows (up to 4 L/min) were induced by aquifer hydrodynamics associated with a fluctuating river boundary located approximately 250 m from the test well. The observed vertical wellbore flows were strongly correlated with fluctuations in river stage, alternating between upward and downward flow throughout the monitoring period in response to changes in river stage. Continuous monitoring of ambient wellbore flows using an electromagnetic borehole flowmeter allowed these effects to be evaluated in concert with continuously monitored river-stage elevations (hourly) and aqueous uranium concentrations (daily) in a long-screen well and an adjacent multilevel well cluster. This study demonstrates that when contaminant concentrations within the aquifer vary significantly over the depth interval interrogated, river-induced vertical wellbore flow can result in variations in measured concentration that nearly encompass the full range of variation in aquifer contaminant concentration with depth. Copyright © 2010 Battelle Memorial Institute. Journal compilation © 2010 National Ground Water Association.

  2. Determination of technetium-99 in environmental samples: A review

    International Nuclear Information System (INIS)

    Shi Keliang; Hou Xiaolin; Roos, Per; Wu Wangsuo

    2012-01-01

    Highlights: ► The source term, physicochemical properties, environmental distribution and behaviour of 99 Tc are presented. ► Various sample pre-treatment and pre-concentration techniques of technetium are discussed. ► Chemical separation and purification techniques for 99 Tc in environmental samples are reviewed. ► Measurement techniques for 99 Tc in environmental level and automated analytical methods are reviewed. ► The reported analytical methods of 99 Tc are critically compared to provide overall information. - Abstract: Due to the lack of a stable technetium isotope, and the high mobility and long half-life, 99 Tc is considered to be one of the most important radionuclides in safety assessment of environmental radioactivity as well as nuclear waste management. 99 Tc is also an important tracer for oceanographic research due to the high technetium solubility in seawater as TcO 4 − . A number of analytical methods, using chemical separation combined with radiometric and mass spectrometric measurement techniques, have been developed over the past decades for determination of 99 Tc in different environmental samples. This article summarizes and compares recently reported chemical separation procedures and measurement methods for determination of 99 Tc. Due to the extremely low concentration of 99 Tc in environmental samples, the sample preparation, pre-concentration, chemical separation and purification for removal of the interferences for detection of 99 Tc are the most important issues governing the accurate determination of 99 Tc. These aspects are discussed in detail in this article. Meanwhile, the different measurement techniques for 99 Tc are also compared with respect to advantages and drawbacks. Novel automated analytical methods for rapid determination of 99 Tc using solid extraction or ion exchange chromatography for separation of 99 Tc, employing flow injection or sequential injection approaches are also discussed.

  3. Determination of uranium and its isotopic ratios in environmental samples

    International Nuclear Information System (INIS)

    Flues Szeles, M.S.M.

    1990-01-01

    A method for the determination of uranium and its isotopic ratios ( sup(235)U/ sup(238)U and sup(234U/ sup(238)U) is established in the present work. The method can be applied in environmental monitoring programs of uranium enrichment facilities. The proposed method is based on the alpha spectrometry technique which is applied after a purification of the sample by using an ionic exchange resin. The total yield achieved was (91 + 5)% with a precision of 5%, an accuracy of 8% and a lower limit of detection of 7,9 x 10 sup(-4)Bq. The uranium determination in samples containing high concentration of iron, which is an interfering element present in environmental samples, particularly in soil and sediment, was also studied. The results obtained by using artificial samples containing iron and uranium in the ratio 1000:1, were considered satisfactory. (author)

  4. Aqueous hybrid ion batteries - An environmentally friendly alternative for stationary energy storage?

    Science.gov (United States)

    Peters, Jens F.; Weil, Marcel

    2017-10-01

    Aqueous hybrid ion batteries (AHIB) are being promoted as an environmentally friendly alternative to existing stationary battery technologies. However, no quantification of their potential environmental impacts has yet been done. This paper presents a prospective life cycle assessment of an AHIB module and compares its performance with lithium-ion and sodium-ion batteries in two different stationary energy storage applications. The findings show that the claim of being an environmentally friendly technology can only be supported with some major limitations. While the AHIB uses abundant and non-toxic materials, it has a very low energy density and requires increased amounts of material for providing a given storage capacity. Per kWh of battery, results comparable to those of the alternative lithium- or sodium-ion batteries are obtained, but significantly higher impacts under global warming and ozone depletion aspects. The comparable high cycle life of the AHIB compensates this partially, requiring less battery replacements over the lifetime of the application. On the other hand, its internal inefficiencies are higher, what becomes the dominating factor when charging majorly fossil based electricity, making AHIB unattractive for this type of applications.

  5. Fluoroquinolone antibiotics in environmental waters: sample preparation and determination.

    Science.gov (United States)

    Speltini, Andrea; Sturini, Michela; Maraschi, Federica; Profumo, Antonella

    2010-04-01

    The aim of this review is to provide a general overview on the analytical methods proposed in the last decade for trace fluoroquinolone (FQ) determination in environmental waters. A large number of studies have been developed on this topic in reason of the importance of their monitoring in the studies of environmental mobility and potential degradation pathways. Every step of the analysis has been carefully considered, with a particular attention to sample preparation, in relationship with the problems involved in the analysis of real matrices. The different strategies to minimise interference from organic matter and to achieve optimal sensitivity, especially important in those samples with lower FQ concentrations, were also highlighted. Results and progress in this field have been described and critically commented. Moreover, a worldwide overview on the presence of FQs in the environmental waters has been reported.

  6. a study of predictors of environmental behaviour using us samples

    African Journals Online (AJOL)

    6. personal attributes questionnaire /PAQ/ and. 7. pollution and technology questionnaire /PTQ/. The demographic data section provided information that helped to describe the sample. The BIEA ass- essed environmental actions taken by the respond- ents during the past year, under each of five action categories, namely ...

  7. Rapid methods for measuring radionuclides in food and environmental samples

    International Nuclear Information System (INIS)

    Perkins, Richard W.

    1995-01-01

    The application of ICP/mass spectrometry for the isotopic analysis of environmental samples, the use of drum assayers for measuring radionuclides in food and a rapid procedure for the measurement of the transuranic elements and thorium, performed at the Pacific Northwest Laboratory are discussed

  8. Analytical techniques for measurement of 99Tc in environmental samples

    International Nuclear Information System (INIS)

    Anon.

    1979-01-01

    Three new methods have been developed for measuring 99 Tc in environmental samples. The most sensitive method is isotope dilution mass spectrometry, which allows measurement of about 1 x 10 -12 grams of 99 Tc. Results on analysis of five samples by this method compare very well with values obtained by a second independent method, which involves counting of beta particles from 99 Tc and internal conversion electrons from /sup 97m/Tc. A third method involving electrothermal atomic absorption has also been developed. Although this method is not as sensitive as the first two techniques, the cost per analysis is expected to be considerably less for certain types of samples

  9. Infrared characterization of environmental samples by pulsed photothermal spectroscopy

    International Nuclear Information System (INIS)

    Seidel, W.; Foerstendorf, H.; Heise, K.H.; Nicolai, R.; Schamlott, A.; Ortega, J.M.; Glotin, F.; Prazeres, R.

    2004-01-01

    Low concentration of toxic radioactive metals in environmental samples often limits the interpretation of results of infrared studies investigating the interaction processes between the metal ions and environmental compartments. For the first time, we could show that photothermal infrared spectroscopy performed with a pulsed free electron laser can provide reliable infrared spectra throughout a distinct spectral range of interest. In this model investigation, we provide vibrational absorption spectra of a rare earth metal salt dissolved in a KBr matrix and a natural calcite sample obtained by photothermal beam deflection (PTBD) technique and FT-IR (Fourier-transform infrared) spectroscopy, respectively. General agreement was found between all spectra of the different recording techniques. Spectral deviations were observed with samples containing low concentration of the rare earth metal salt indicating a lower detection limit of the photothermal method as compared to conventional FT-IR spectroscopy. (authors)

  10. Environmental monitoring master sampling schedule, January--December 1990

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, L.E.

    1990-01-01

    Environmental monitoring of the Hanford Site is conducted by the Pacific Northwest Laboratory (PNL) for the US Department of Energy (DOE). This document contains the planned schedule for routine sample collection for calendar year 1990 for the Environment Surveillance and Ground-Water Monitoring Projects. This schedule is subject to modification during the year in response to changes in Site operations, program requirements, and the nature of the observed results. Operational limitations such as weather, mechanical failures, sample availability, etc., may also require schedule modifications. Changes will be documented in the respective project files, but this plan will not be reissued. The purpose of these monitoring projects is to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs. This schedule includes ground-water sampling performed by PNL for environmental surveillance of the Hanford Site.

  11. DOE methods for evaluating environmental and waste management samples

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K.

    1994-04-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) is a resource intended to support sampling and analytical activities for the evaluation of environmental and waste management samples from U.S. Department of Energy (DOE) sites. DOE Methods is the result of extensive cooperation from all DOE analytical laboratories. All of these laboratories have contributed key information and provided technical reviews as well as significant moral support leading to the success of this document. DOE Methods is designed to encompass methods for collecting representative samples and for determining the radioisotope activity and organic and inorganic composition of a sample. These determinations will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the U.S. Environmental Protection Agency, or others. The development of DOE Methods is supported by the Laboratory Management Division of the DOE. Methods are prepared for entry into DOE Methods as chapter editors, together with DOE and other participants in this program, identify analytical and sampling method needs. Unique methods or methods consolidated from similar procedures in the DOE Procedures Database are selected for potential inclusion in this document. Initial selection is based largely on DOE needs and procedure applicability and completeness. Methods appearing in this document are one of two types. open-quotes Draftclose quotes or open-quotes Verified.close quotes. open-quotes Draftclose quotes methods that have been reviewed internally and show potential for eventual verification are included in this document, but they have not been reviewed externally, and their precision and bias may not be known. open-quotes Verifiedclose quotes methods in DOE Methods have been reviewed by volunteers from various DOE sites and private corporations

  12. Determination of strontium-90 in the environmental samples at PINSTECH

    International Nuclear Information System (INIS)

    Perveen, N.; Aziz, A.

    1979-01-01

    Strontium-90 a bone seeking radionuclide and a long lived beta emitter is one of the toxic radionuclides detected in the environment arising mainly from the fall out from nuclear detonations. Its concentration in various environmental media such as air, precipitation, surface water, vegetables and other items of diet was measured. This report describes the method of collection, treatment and radiochemical analyses of environmental samples for the determination of Sr-90. The levels of Sr-90 concentration in these media are also recorded. (authors)

  13. DOE methods for evaluating environmental and waste management samples

    Energy Technology Data Exchange (ETDEWEB)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K. [eds.

    1994-10-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) is a resource intended to support sampling and analytical activities for the evaluation of environmental and waste management samples from U.S. Department of Energy (DOE) sites. DOE Methods is the result of extensive cooperation from all DOE analytical laboratories. All of these laboratories have contributed key information and provided technical reviews as well as significant moral support leading to the success of this document. DOE Methods is designed to encompass methods for collecting representative samples and for determining the radioisotope activity and organic and inorganic composition of a sample. These determinations will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the U.S. Environmental Protection Agency, or others. The development of DOE Methods is supported by the Analytical Services Division of DOE. Unique methods or methods consolidated from similar procedures in the DOE Procedures Database are selected for potential inclusion in this document. Initial selection is based largely on DOE needs and procedure applicability and completeness. Methods appearing in this document are one of two types, {open_quotes}Draft{close_quotes} or {open_quotes}Verified{close_quotes}. {open_quotes}Draft{close_quotes} methods that have been reviewed internally and show potential for eventual verification are included in this document, but they have not been reviewed externally, and their precision and bias may not be known. {open_quotes}Verified{close_quotes} methods in DOE Methods have been reviewed by volunteers from various DOE sites and private corporations. These methods have delineated measures of precision and accuracy.

  14. DOE methods for evaluating environmental and waste management samples

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Thomas, B.L.; Riley, R.G.; Sklarew, D.S.; Mong, G.M.; Fadeff, S.K.

    1994-10-01

    DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) is a resource intended to support sampling and analytical activities for the evaluation of environmental and waste management samples from U.S. Department of Energy (DOE) sites. DOE Methods is the result of extensive cooperation from all DOE analytical laboratories. All of these laboratories have contributed key information and provided technical reviews as well as significant moral support leading to the success of this document. DOE Methods is designed to encompass methods for collecting representative samples and for determining the radioisotope activity and organic and inorganic composition of a sample. These determinations will aid in defining the type and breadth of contamination and thus determine the extent of environmental restoration or waste management actions needed, as defined by the DOE, the U.S. Environmental Protection Agency, or others. The development of DOE Methods is supported by the Analytical Services Division of DOE. Unique methods or methods consolidated from similar procedures in the DOE Procedures Database are selected for potential inclusion in this document. Initial selection is based largely on DOE needs and procedure applicability and completeness. Methods appearing in this document are one of two types, open-quotes Draftclose quotes or open-quotes Verifiedclose quotes. open-quotes Draftclose quotes methods that have been reviewed internally and show potential for eventual verification are included in this document, but they have not been reviewed externally, and their precision and bias may not be known. open-quotes Verifiedclose quotes methods in DOE Methods have been reviewed by volunteers from various DOE sites and private corporations. These methods have delineated measures of precision and accuracy

  15. Comparison of analysis techniques by liquid scintillation and Cerenkov Effect for 40K quantification in aqueous samples

    International Nuclear Information System (INIS)

    Miranda C, L.; Davila R, J. I.; Lopez del R, H.; Mireles G, F.

    2015-09-01

    In this work the counting by liquid scintillation and Cerenkov Effect to quantify 40 K in aqueous samples was used. The performance of both techniques was studied by comparing the response of three commercial liquid scintillation OptiPhase HiSafe 3, Ultima Gold Ab and OptiPhase TriSafe, the vial type and presentation conditions of the sample for counting. In liquid scintillation, the ability to form homogeneous mixtures depended on the ionic strength of the aqueous solutions. The scintillator OptiPhase HiSafe 3 showed a greater charge capacity for solutions with high ionic strength (<3.4), while the scintillator OptiSafe TriSafe no form homogeneous mixtures for solutions of ionic strength higher than 0.3. Counting efficiencies for different proportions of sample and scintillator near 100% for the scintillators OptiSafe HiSafe 3 and Ultima Gold Ab were obtained. In the counting by Cerenkov Effect, the efficiency and sensitivity depended of the vial type; polyethylene vials were more suitable for counting that the glass vials. The sample volume had not significant effect on counting efficiency, obtaining an average value of 44.8% for polyethylene vials and 37.3% for glass vials. Therefore, the liquid scintillation was more efficient and sensitive for the measurement of 40 K in aqueous solutions. (Author)

  16. Analysis of Direct Samples of Extraterrestrial, Organic-Bearing, Aqueous Fluids

    Science.gov (United States)

    Zolensky, Michael

    2016-01-01

    I will describe water we have found in 4.5 billion year old extraterrestrial salt, and the organics that are also present. We hypothesize that organics being carried through the parent body of the halite have been deposited adjacent to the fluid inclusions, where they have been preserved against any thermal metamorphism. We are making bulk compositional, carbon and hydrogen isotopic measurements of solid organic phases associated with the aqueous fluid inclusions in the meteorites. We will compare these organics with those found in chondrites and Wild-2 comet coma particles to determine whether these classes of organics had an origin within aqueous solutions.

  17. Spectrophotometric Determination of Boron in Environmental Water Samples

    International Nuclear Information System (INIS)

    San San; Khin Win Kyi; Kwaw Naing

    2002-02-01

    The present paper deals with the study on the methods for the determination of boron in the environmental water samples. The standard methods which are useful for this determination are discussed thoroughly in this work. Among the standard methods approved by American Public Health Association, the carmine method was selected for this study. Prior to the determination of boron in the water samples, the precision and accuracy of the methods of choice were examined by using standard boron solutions. The determination of Boron was carried out by using water samples, waste water from Aquaculture Research Centre, University of Yangon, the Ayeyarwady River water near Magway Myathalon Pagoda in Magway Division, ground water from Sanchaung Township, and tap water from Universities' Research Centre, University of Yangon. Analyses of these water samples were done and statistical treatment of the results was carried out. (author)

  18. Development of environmental sample analysis techniques for safeguards

    International Nuclear Information System (INIS)

    Magara, Masaaki; Hanzawa, Yukiko; Esaka, Fumitaka

    1999-01-01

    JAERI has been developing environmental sample analysis techniques for safeguards and preparing a clean chemistry laboratory with clean rooms. Methods to be developed are a bulk analysis and a particle analysis. In the bulk analysis, Inductively-Coupled Plasma Mass Spectrometer or Thermal Ionization Mass Spectrometer are used to measure nuclear materials after chemical treatment of sample. In the particle analysis, Electron Probe Micro Analyzer and Secondary Ion Mass Spectrometer are used for elemental analysis and isotopic analysis, respectively. The design of the clean chemistry laboratory has been carried out and construction will be completed by the end of March, 2001. (author)

  19. The contents of fifteen essential, trace and toxic elements in some green tea samples and in their aqueous extracts

    International Nuclear Information System (INIS)

    Memon, A.N.; Kazi, T.G.

    2002-01-01

    The content of fifteen elements such as Ca, Mg, Na, K, Mn, Zn, Co, Cu, Cr, Ni, Pd, Cd, Ba and Al were determined in Green Tea samples imported from different countries such as India, China, Kenya and Bangladesh in packets and without packets were purchased from authorized tea dealers in Peshawar. Wet ashing procedures were employed for decomposing the organic matter in the tea samples. Aqueous extract of each green tea sample was also prepared by heating with de-ionized water at 80 /sup o/C on electric heating plates. (author)

  20. Environmental sampling accounting at the Savannah River Plant

    International Nuclear Information System (INIS)

    Zeigler, C.C.; Wood, M.B.

    1978-06-01

    At the Savannah River Plant Environmental Monitoring Laboratories, a computer-based systematic accounting method was developed to ensure that all scheduled samples are collected, processed through the laboratory, and counted without delay. The system employs an IBM 360/195 computer with a magnetic tape master file, an on-line disk file, and cathode ray tube (CRT) terminals. Scheduling and accounting are accomplished by using computer-generated schedules, collection labels, and output/input cards. For each scheduled sample and analysis, a printed card is issued for collection, laboratory analysis, and counting. The cards also contain information needed by personnel performing the jobs, such as sample location, aliquot to be processed, or procedure number. Manual entries are made on the cards when each step in the process is completed. Additional pertinent data are also manually entered on the cards; e.g., entries are made explaining why a sample is not collected, the sample aliquot in the event a nonstandard aliquot is processed, field measurement results, and analytical results. These manually entered data are keypunched and read into the computer files. The computer files are audited daily, and summaries of samples not processed in pre-established normal time intervals are issued. The progress of sample analyses can also be readily determined at any time using the CRT terminal. Historic data are also maintained on magnetic tape and workload summaries are issued showing the number of samples and number of determinations per month

  1. Environmental sampling: Issues for the cut-off regime

    International Nuclear Information System (INIS)

    Fearey, B.L.

    1995-01-01

    The fissile material cut-off treaty (FMCT) initiative under the Conference on Disarmament mandate is envisioned to include certain aspects of environmental sampling and monitoring. One of the intents of this treaty is to bring certain non-NPT signatories (e.g., threshold states) under this treaty agreement along with the nuclear weapon states (NWSs). This paper provides a brief overview of some of the relevant issues that may be involved in the implementation and use of environmental monitoring for (1) verification of the cut-off regime declarations, (2) the detection of undeclared activities, and, (3) application in non-routine inspections. The intent is to provide backstopping information important for treaty negotiators. Specific issues addressed within this paper include signature sampling, differences in the proposed detection regime, potential signature integrators, specific examples and spoofing concerns. Many of these issues must be carefully considered and weighed in order to create a credibly verifiable inspection regime. Importantly, the cut-off treaty must enable nondiscriminatory implementation, while carefully assuring that nonproliferation treaty requirements are maintained (i.e., preventing unintentional release of critical weapons design information--potentially through environmental sampling and analysis)

  2. Transuranium analysis methodologies for biological and environmental samples

    International Nuclear Information System (INIS)

    Wessman, R.A.; Lee, K.D.; Curry, B.; Leventhal, L.

    1978-01-01

    Analytical procedures for the most abundant transuranium nuclides in the environment (i.e., plutonium and, to a lesser extent, americium) are available. There is a lack of procedures for doing sequential analysis for Np, Pu, Am, and Cm in environmental samples, primarily because of current emphasis on Pu and Am. Reprocessing requirements and waste disposal connected with the fuel cycle indicate that neptunium and curium must be considered in environmental radioactive assessments. Therefore it was necessary to develop procedures that determine all four of these radionuclides in the environment. The state of the art of transuranium analysis methodology as applied to environmental samples is discussed relative to different sample sources, such as soil, vegetation, air, water, and animals. Isotope-dilution analysis with 243 Am ( 239 Np) and 236 Pu or 242 Pu radionuclide tracers is used. Americium and curium are analyzed as a group, with 243 Am as the tracer. Sequential extraction procedures employing bis(2-ethyl-hexyl)orthophosphoric acid (HDEHP) were found to result in lower yields and higher Am--Cm fractionation than ion-exchange methods

  3. Development of novel and sensitive methods for the determination of sulfide in aqueous samples by hydrogen sulfide generation-inductively coupled plasma-atomic emission spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Colon, M. [Department of Chemistry, University of Girona, Campus Montilivi, 17071 Girona (Spain); Departamento de Quimica Analitica, Nutricion y Bromatologia, University of Alicante, 03080 Alicante (Spain); Todoli, J.L. [Departamento de Quimica Analitica, Nutricion y Bromatologia, University of Alicante, 03080 Alicante (Spain); Hidalgo, M. [Department of Chemistry, University of Girona, Campus Montilivi, 17071 Girona (Spain); Iglesias, M. [Department of Chemistry, University of Girona, Campus Montilivi, 17071 Girona (Spain)], E-mail: monica.iglesias@udg.es

    2008-02-25

    Two new, simple and accurate methods for the determination of sulfide (S{sup 2-}) at low levels ({mu}g L{sup -1}) in aqueous samples were developed. The generation of hydrogen sulfide (H{sub 2}S) took place in a coil where sulfide reacted with hydrochloric acid. The resulting H{sub 2}S was then introduced as a vapor into an inductively coupled plasma-atomic emission spectrometer (ICP-AES) and sulfur emission intensity was measured at 180.669 nm. In comparison to when aqueous sulfide was introduced, the introduction of sulfur as H{sub 2}S enhanced the sulfur signal emission. By setting a gas separator at the end of the reaction coil, reduced sulfur species in the form of H{sub 2}S were removed from the water matrix, thus, interferences could be avoided. Alternatively, the gas separator was replaced by a nebulizer/spray chamber combination to introduce the sample matrix and reagents into the plasma. This methodology allowed the determination of both sulfide and sulfate in aqueous samples. For both methods the linear response was found to range from 5 {mu}g L{sup -1} to 25 mg L{sup -1} of sulfide. Detection limits of 5 {mu}g L{sup -1} and 6 {mu}g L{sup -1} were obtained with and without the gas separator, respectively. These new methods were evaluated by comparison to the standard potentiometric method and were successfully applied to the analysis of reduced sulfur species in environmental waters.

  4. Cyclohexylamine as extraction solvent and chelating agent in extraction and preconcentration of some heavy metals in aqueous samples based on heat-induced homogeneous liquid-liquid extraction.

    Science.gov (United States)

    Sorouraddin, Saeed Mohammad; Farajzadeh, Mir Ali; Okhravi, Tohid

    2017-12-01

    A new sample preparation method has been developed for extraction and preconcentration of some heavy metal cations in aqueous samples using cyclohexylamine-based homogeneous liquid-liquid microextraction. In the proposed method, cyclohexylamine was used as both the complexing agent and the extraction solvent. For this purpose, cyclohexylamine at µL level was initially added into an aqueous solution containing Co(II), Ni(II), and Cu(II) ions which was placed in a glass test tube. The mixture was shaken for forming a homogeneous solution. Then sodium chloride was added to the solution. After shaking manually again, the test tube was placed in a water bath thermostated at 70°C. Due to lower solubility of cyclohexylamine at the elevated temperature, a cloudy solution was formed. The fine droplets of cyclohexylamine containing cation-cyclohexylamine complexes were collected on the top of the aqueous phase by centrifuging. The enriched analytes in the upper phase were determined by graphite furnace atomic absorption spectrometry. Several variables possibly affecting the extraction efficiency were investigated and optimized. Under the optimum conditions the calibration curves were linear in the ranges of 80-1000, 40-700, and 80-800ngL -1 for Co 2+ , Ni 2+ , and Cu 2+ , respectively. Repeatability of the proposed method, expressed as relative standard deviation, ranged from 3.3% to 5.2% (n = 6, C = 200ngL -1 ). Moreover, the obtained detection limits of the selected analytes were in the range of 15.3-37.7ngL -1 . The accuracy of the developed procedure was verified by analyzing a certified reference material, namely NRCC-SLRS4 Riverine water. Finally, the proposed method was successfully applied for the simultaneous analysis of the selected analytes in environmental water samples. Copyright © 2017 Elsevier B.V. All rights reserved.

  5. Multi-stir bar sorptive extraction for analysis of odor compounds in aqueous samples.

    Science.gov (United States)

    Ochiai, Nobuo; Sasamoto, Kikuo; Ieda, Teruyo; David, Frank; Sandra, Pat

    2013-11-08

    As reproducible coating of stir bars with more polar phases was found to be very difficult, a supporting grid was used in the development of an ethyleneglycol-modified Silicone (EG Silicone) coated stir bar. This new polar coating showed good performance for the extraction of polar solutes, but long term use also showed degradation of the coating due to friction while stirring. In order to address the lower robustness of the EG Silicone stir bar which has a much softer coating compared to a conventional polydimethylsiloxane (PDMS) stir bar, a novel SBSE procedure termed multi-SBSE ((m)SBSE) was developed. (m)SBSE consists of the robust PDMS stir bar stirring at the bottom of the vial and the EG Silicone stir bar attached on the inner side wall of the vial (a magnetic clip is used for the set-up). After extraction, the two stir bars are placed in a single glass desorption liner and are simultaneously thermally desorbed. The desorbed compounds were analyzed by thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS). Compared to conventional SBSE, (m)SBSE provides more uniform enrichment of a wide range of odor compounds in aqueous sample since both stir bars can complement each other, while eliminating the damage of the EG Silicone phase during the extraction. The robustness of the EG Silicone stir bar was dramatically increased and more than 30 extraction and desorption cycles were possible without loss in performance. The recoveries for polar solutes such as 2-acetyl pyrrole (logKow: 0.55), benzyl alcohol (logKow: 1.08), guaiacol (logKow: 1.34), and indole (logKow: 2.05) were increased by a factor of about 2-7. The (m)SBSE-TD-GC-MS method showed good linearity (r(2)>0.9913) and high sensitivity (limit of detection: 0.011-0.071 ng mL(-1)) for the test compounds spiked in water. The feasibility and benefit of the method was demonstrated with analysis of odor compounds in roasted green tea. The normalized areas obtained from (m)SBSE showed the best

  6. Reaction path sampling of the reaction between iron(II) and hydrogen peroxide in aqueous solution

    NARCIS (Netherlands)

    Ensing, B.; Baerends, E.J.

    2002-01-01

    Previously, we have studied the coordination and dissociation of hydrogen peroxide with iron(II) in aqueous solution by Car-Parrinello molecular dynamics at room temperature. We presented a few illustrative reaction events, in which the ferryl ion ([Fe(IV)O

  7. A comparison of some radionuclide contents in environmental samples

    International Nuclear Information System (INIS)

    Shiraishi, Kunio; Muramatsu, Yasuyuki; Nakajima, Toshiyuki; Yamamoto, Masayoshi; Los, I.P.; Kamarikov, I.Yu.; Buzinny, M.G.

    1992-01-01

    Global contamination by radionuclides was likely induced through the Chernobyl nuclear accident in 1986. Environmental samples such as fish, milk, total diet samples etc., collected in Kiev, in the vicinity of Chernobyl, and Mito city, Japan, were analyzed for six selected radionuclides. After samples were dry-ashed, radioactivities of Cs-137, Cs-134, K-40, Co-60, and Mn-54 were determined by gamma-ray spectroscopy with a germanium detector. Strontium-90 was determined by low-background beta-spectrometry after chemical separations by fuming nitric acid. Concentrations of radioactivities in the Kiev samples, in the vicinity of the Chernobyl, are shown below. For comparison, values obtained in Japan, including literature values, are shown in parentheses. Radioactivities in airborne dust were: Sr-90, 63 mBq/m 3 (0.001-0.1); Cs-137, 26 mBg/m 3 (0.001-1); Cs-134, 4 mBq/m 3 ; Co-60, 4 mBq/m 3 ; Mn-54, 2 mBq/m 3 . Radioactivities of milk were as follows; Sr-90, 0.25-1.2 Bq/liter (0.01-0.1); Cs-137, 6-77 Bq/liter (0.01-1); Cs-134, 2-8 Bq/liter. Radioactivities of Sr-90 and Cs-137 for fish (carp), were found to be 3-75 Bq/kg-fresh (0.76-0.98) and 46-2130 Bq/kg-fresh (<0.8), respectively. It was observed that the daily intake of Sr-90 and Cs-137 were 0.25 Bq (0.1) and 0.43 Bq (0.1) per person, respectively. Due to the small number of samples analyzed it is premature to draw a firm conclusion from this study. However, the levels of radionuclides in environmental samples were found to differ between Kiev and Mito with wide ranges depending on the samples. (author)

  8. Sampling, storage and sample preparation procedures for X ray fluorescence analysis of environmental materials

    International Nuclear Information System (INIS)

    1997-06-01

    X ray fluorescence (XRF) method is one of the most commonly used nuclear analytical technique because of its multielement and non-destructive character, speed, economy and ease of operation. From the point of view of quality assurance practices, sampling and sample preparation procedures are the most crucial steps in all analytical techniques, (including X ray fluorescence) applied for the analysis of heterogeneous materials. This technical document covers recent modes of the X ray fluorescence method and recent developments in sample preparation techniques for the analysis of environmental materials. Refs, figs, tabs

  9. Environmental sample accounting at the Savannah River Plant

    International Nuclear Information System (INIS)

    Zeigler, C.C.; Wood, M.B.

    1978-01-01

    At the Savannah River Plant Environmental Monitoring Laboratories, a computer-based systematic accounting method was developed to ensure that all scheduled samples are collected, processed through the laboratory, and counted without delay. The system employs an IBM 360/195 computer with a magnetic tape master file, an online disk file, and cathode ray tube (CRT) terminals. Scheduling and accounting are accomplished using computer-generated schedules, bottle labels, and output/ input cards. A printed card is issued for the collecting, analyzing, and counting of each scheduled sample. The card also contains information for the personnel who are to perform the work, e.g., sample location, aliquot to be processed, and procedure to be used. Manual entries are made on the card when each step in the process is completed. Additional pertinent data such as the reason a sample is not collected, the need for a nonstandard aliquot, and field measurement results are keypunched and then read into the computer files as required. The computer files are audited daily and summaries showing samples not processed in pre-established normal schedules are provided. The progress of sample analyses is readily determined at any time using the CRT terminal. Historic data are maintained on magnetic tape, and workload summaries showing the number of samples and number of determinations per month are issued. (author)

  10. Modified electrode voltammetric sensors for trace metals in environmental samples

    Directory of Open Access Journals (Sweden)

    Brett Christopher M.A.

    2000-01-01

    Full Text Available Nafion-modified mercury thin film electrodes have been investigated for the analysis of trace metals in environmental samples of waters and effluent by batch injection analysis with square wave anodic stripping voltammetry. The method, involving injection over the detector electrode of untreated samples of volume of the order of 50 microlitres has fast response, blocking and fouling of the electrode is minimum as shown by studies with surface-active components. Comparison is made between glassy carbon substrate electrodes and carbon fibre microelectrode array substrates, the latter leading to a small sensitivity enhancement. Application to analysis of river water and industrial effluent for labile zinc, cadmium, lead and copper ions is demonstrated in collected samples and after acid digestion.

  11. Air-assisted dispersive liquid-liquid microextraction based on a new hydrophobic deep eutectic solvent for the preconcentration of benzophenone-type UV filters from aqueous samples.

    Science.gov (United States)

    Ge, Dandan; Zhang, Yi; Dai, Yixiu; Yang, Shumin

    2017-12-28

    Deep eutectic solvents are considered as new and green solvents that can be widely used in analytical chemistry such as microextraction. In the present work, a new dl-menthol-based hydrophobic deep eutectic solvent was synthesized and used as extraction solvents in an air-assisted dispersive liquid-liquid microextraction method for preconcentration and extraction of benzophenone-type UV filters from aqueous samples followed by high-performance liquid chromatography with diode array detection. In an experiment, the deep eutectic solvent formed by dl-menthol and decanoic acid was added to an aqueous solution containing the UV filters, and then the mixture was sucked up and injected five times by using a glass syringe, and a cloudy state was achieved. After extraction, the solution was centrifuged and the upper phase was subjected to high-performance liquid chromatography for analysis. Various parameters such as the type and volume of the deep eutectic solvent, number of pulling, and pushing cycles, solution pH and salt concentration were investigated and optimized. Under the optimum conditions, the developed method exhibited low limits of detection and limits of quantitation, good linearity, and precision. Finally, the proposed method was successfully applied to determine the benzophenone-type filters in environmental water samples with relative recoveries of 88.8-105.9%. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. Environmental baselines by NAA of tree-ring samples

    International Nuclear Information System (INIS)

    Ricci, E.; Harris, W.F.; Reichle, D.E.

    1974-01-01

    A collaborative effort has been made between two ORNL divisions at gaining information about environmental baselines and trace contamination levels in the Oak Ridge--Knoxville area. Instrumental, absolute, multielement neutron activation is currently providing data both on pristine conditions of a century ago and on gradual atmospheric contamination by analysis of rings from trees grown in a relatively unpolluted area and in a city. Experience on absolute NAA at ORNL's High Flux NAA Laboratory is discussed in detail, as well as multielement results corresponding to years 1872-76 (Increment No. 20) to 1968-72 (Increment No. 1), for two cores, on each of two trees studied. Concentrations were determined for 13 elements simultaneously in each of 12 different samples. Results show the great potential of this technique in the determination of environmental baselines and trace contamination levels

  13. Recent results of the investigation of a micro-fluidic sampling chip and sampling system for hot cell aqueous processing streams

    Energy Technology Data Exchange (ETDEWEB)

    Tripp, J.; Smith, T.; Law, J. [Idaho National Laboratory: P.O. Box 1625, Idaho Falls, ID 83415 (United States)

    2013-07-01

    A Fuel Cycle Research and Development project has investigated an innovative sampling method that could evolve into the next generation sampling and analysis system for metallic elements present in aqueous processing streams. Initially sampling technologies were evaluated and micro-fluidic sampling chip technology was selected and tested. A conceptual design for a fully automated microcapillary-based system was completed and a robotic automated sampling system was fabricated. The mechanical and sampling operation of the completed sampling system was investigated. Different sampling volumes have been tested. It appears that the 10 μl volume has produced data that had much smaller relative standard deviations than the 2 μl volume. In addition, the production of a less expensive, mass produced sampling chip was investigated to avoid chip reuse thus increasing sampling reproducibility/accuracy. The micro-fluidic-based robotic sampling system's mechanical elements were tested to ensure analytical reproducibility and the optimum robotic handling of micro-fluidic sampling chips. (authors)

  14. Selective removal of dicamba from aqueous samples using molecularly imprinted polymer nanospheres

    Directory of Open Access Journals (Sweden)

    Tooraj Beyki

    2016-07-01

    Full Text Available For the first time, uniform molecularly imprinted polymer (MIP nanoparticles were prepared using dicamba as a template. The MIP nanoparticles were successfully synthesized by precipitation polymerization using methacrylic acid (MAA as functional monomer, trimethylolpropane trimethacrylate (TRIM as cross-linker and acetonitrile as porogen. The produced polymers were characterized by differential scanning calorimetry (DSC and their morphology was precisely examined by scanning electron microscopy (SEM. The MIP nanospheres were obtained with the average diameter of 234 nm. Batch-wise guest binding experiments were carried out to determine the removal efficiency of the produced MIP nanoparticles towards the template molecule in aqueous solutions. The MIP showed outstanding affinity toward dicamba in aqueous solution with maximum removal efficiency of 87.5% at 300 mg.L-1 of dicamba solution. The MIP exhibited higher adsorption efficiency compared with the corresponding non-imprinted polymer (NIP as well as outstanding selectivity towards dicamba relative to the template analog in an aqueous solution. Moreover, effects of pH on removal efficiency and selectivity of MIP were evaluated in detail.

  15. Rapid determination of 226Ra in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, Sherrod L.; Culligan, Brian K.

    2012-02-04

    A new rapid method for the determination of {sup 228}Ra in natural water samples has been developed at the SRNL/EBL (Savannah River National Lab/ Environmental Bioassay Laboratory) that can be used for emergency response or routine samples. While gamma spectrometry can be employed with sufficient detection limits to determine {sup 228}Ra in solid samples (via {sup 228}Ac) , radiochemical methods that employ gas flow proportional counting techniques typically provide lower MDA (Minimal Detectable Activity) levels for the determination of {sup 228}Ra in water samples. Most radiochemical methods for {sup 228}Ra collect and purify {sup 228}Ra and allow for {sup 228}Ac daughter ingrowth for ~36 hours. In this new SRNL/EBL approach, {sup 228}Ac is collected and purified from the water sample without waiting to eliminate this delay. The sample preparation requires only about 4 hours so that {sup 228}Ra assay results on water samples can be achieved in < 6 hours. The method uses a rapid calcium carbonate precipitation enhanced with a small amount of phosphate added to enhance chemical yields (typically >90%), followed by rapid cation exchange removal of calcium. Lead, bismuth, uranium, thorium and protactinium isotopes are also removed by the cation exchange separation. {sup 228}Ac is eluted from the cation resin directly onto a DGA Resin cartridge attached to the bottom of the cation column to purify {sup 228}Ac. DGA Resin also removes lead and bismuth isotopes, along with Sr isotopes and {sup 90}Y. La is used to determine {sup 228}Ac chemical yield via ICP-MS, but {sup 133}Ba can also be used instead if ICP-MS assay is not available. Unlike some older methods, no lead or strontium holdback carriers or continual readjustment of sample pH is required.

  16. Molecular Identification of Gambierdiscus and Fukuyoa (Dinophyceae from Environmental Samples

    Directory of Open Access Journals (Sweden)

    Kirsty F. Smith

    2017-08-01

    Full Text Available Ciguatera Fish Poisoning (CFP is increasing across the Pacific and the distribution of the causative dinoflagellates appears to be expanding. Subtle differences in thecal plate morphology are used to distinguish dinoflagellate species, which are difficult to determine using light microscopy. For these reasons we sought to develop a Quantitative PCR assay that would detect all species from both Gambierdiscus and Fukuyoa genera in order to rapidly screen environmental samples for potentially toxic species. Additionally, a specific assay for F. paulensis was developed as this species is of concern in New Zealand coastal waters. Using the assays we analyzed 31 samples from three locations around New Zealand and the Kingdom of Tonga. Fourteen samples in total were positive for Gambierdiscus/Fukuyoa and two samples were also positive using the F. paulensis assay. Samples from the Kermadec Islands were further characterized using high-throughput sequencing metabarcoding. The majority of reads corresponded to Gambierdiscus species with three species identified at all sites (G. australes, G. honu and G. polynesiensis. This is the first confirmed identification of G. polynesiensis, a known ciguatoxin producer, in New Zealand waters. Other known toxin-producing genera were also detected, included Alexandrium, Amphidinium, Azadinium, Dinophysis, Ostreopsis, and Prorocentrum.

  17. Rapid extraction and assay of uranium from environmental surface samples

    Energy Technology Data Exchange (ETDEWEB)

    Barrett, Christopher A.; Chouyyok, Wilaiwan; Speakman, Robert J.; Olsen, Khris B.; Addleman, Raymond Shane

    2017-10-01

    Extraction methods enabling faster removal and concentration of uranium compounds for improved trace and low-level assay are demonstrated for standard surface sampling material in support of nuclear safeguards efforts, health monitoring, and other nuclear analysis applications. A key problem with the existing surface sampling swipes is the requirement for complete digestion of sample and sampling matrix. This is a time-consuming and labour-intensive process that limits laboratory throughput, elevates costs, and increases background levels. Various extraction methods are explored for their potential to quickly and efficiently remove different chemical forms of uranium from standard surface sampling material. A combination of carbonate and peroxide solutions is shown to give the most rapid and complete form of uranyl compound extraction and dissolution. This rapid extraction process is demonstrated to be compatible with standard inductive coupled plasma mass spectrometry methods for uranium isotopic assay as well as screening techniques such as x-ray fluorescence. The general approach described has application beyond uranium to other analytes of nuclear forensic interest (e.g., rare earth elements and plutonium) as well as heavy metals for environmental and industrial hygiene monitoring.

  18. Stability of volatile organics in environmental soil samples. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Maskarinec, M.P.; Bayne, C.K.; Jenkins, R.A.; Johnson, L.H.; Holladay, S.K.

    1992-11-01

    This report focuses on data generated for the purpose of establishing the stability of 19 volatile organic compounds in environmental soil samples. The study was carried out over a 56 day (for two soils) and a 111 day (for one reference soil) time frame and took into account as many variables as possible within the constraints of budget and time. The objectives of the study were: 1) to provide a data base which could be used to provide guidance on pre-analytical holding times for regulatory purposes; and 2) to provide a basis for the evaluation of data which is generated outside of the currently allowable holding times.

  19. Stability of volatile organics in environmental soil samples

    Energy Technology Data Exchange (ETDEWEB)

    Maskarinec, M.P.; Bayne, C.K.; Jenkins, R.A.; Johnson, L.H.; Holladay, S.K.

    1992-11-01

    This report focuses on data generated for the purpose of establishing the stability of 19 volatile organic compounds in environmental soil samples. The study was carried out over a 56 day (for two soils) and a 111 day (for one reference soil) time frame and took into account as many variables as possible within the constraints of budget and time. The objectives of the study were: 1) to provide a data base which could be used to provide guidance on pre-analytical holding times for regulatory purposes; and 2) to provide a basis for the evaluation of data which is generated outside of the currently allowable holding times.

  20. Spectrophotometric determination of vanadium in environmental and biological samples

    International Nuclear Information System (INIS)

    Rekha, D.; Krishnapriya, B.; Subrahmanyam, P.; Reddyprasad, P.; Dilip Kumar, J.; Chiranjeevi, P.

    2007-01-01

    The method is based on oxidation of p-nitro aniline by vanadium (V) followed by coupling reaction with N-(1-naphthalene-1-y1)ethane-1, 2-diaminedihydrochloride (NEDA) in basic medium of pH 8 to give purple colored derivative. The derivative having an λ max 525nm is stable for 10 days. Beer's law is obeyed for vanadium (V) in the concentration range of 0.03-4.5 μg ml -1 . The proposed method was successfully applied to the analysis of vanadium in environmental and biological samples. (author)

  1. Nonactivation interaction techniques in the analysis of environmental samples

    International Nuclear Information System (INIS)

    Tolgyessy, J.

    1986-01-01

    Nonactivation interaction analytical methods are based on the interaction processes of nuclear and X-ray radiation with a sample, leading to their absorption and backscattering, to the ionization of gases or excitation of fluorescent X-ray by radiation, but not to the activation of determined elements. From the point of view of environmental analysis, the most useful nonactivation interaction techniques are X-ray fluorescence by photon or charged particle excitation, ionization of gases by nuclear radiation, elastic scattering of charged particles and backscattering of beta radiation. The significant advantage of these methods is that they are nondestructive. (author)

  2. Detection of iodine-129 in some environmental samples

    International Nuclear Information System (INIS)

    Ikeda, Nagao

    1981-01-01

    The recent accumulation of the long-lived isotope of iodine, 129 I, which is released in environment by the peaceful use of nuclear energy or nuclear test explosion is becoming important in the view point of the internal exposure by the low level radiation. The studies on the detection of determination of 129 I in environmental samples so far published are still very few. The authors tried to detect 129 I in some Japanese seaweeds and soil samples with the aid of the activation method by using the nuclear reaction of 129 I(n, #betta#) 130 I. The samples analysed in this work are tangle (Laminaria japonica) for daily food grown in Hidaka, Hokkaido and uncultivated soil collected in Tokai, Ibaraki Pref. As the #betta#-ray peak indicator for 130 I, cesium oxide and the aged radioisotope product of 131 I are also subjected to the neutron irradiation. From cesium oxide, 130 I is formed by the reaction of 133 Cs(n, α) 130 I. An aged vial of the 131 I product is expected to contain very minute amounts of 129 I which is also produced both by the fission of uranium and neutron capture reaction of tellurium followed by #betta# - -decay. The #betta#-ray spectra for the soil sample, cesium oxide and the aged 131 I vial are shown in Fig. 1. No appreciable peak was found for the seaweeds sample. In the #betta#-ray spectra for irradiated cesium oxide and the aged 131 I vial, several typical peaks for 130 I were observed. By comparing with these peaks, several small peaks which appear at around 418, 536 and 739 keV in the soil sample can be attributed to those of 130 I. The 129 I content in the soil sample is roughly estimated to be 2 x 10 - 10 Bq/g. (author)

  3. Full evaporation dynamic headspace and gas chromatography-mass spectrometry for uniform enrichment of odor compounds in aqueous samples.

    Science.gov (United States)

    Ochiai, Nobuo; Sasamoto, Kikuo; Hoffmann, Andreas; Okanoya, Kazunori

    2012-06-01

    A method for analysis of a wide range of odor compounds in aqueous samples at sub-ng mL⁻¹ to μg mL⁻¹ levels was developed by full evaporation dynamic headspace (FEDHS) and gas chromatography-mass spectrometry (GC-MS). Compared to conventional DHS and headspace solid phase microextraction (HS-SPME), FEDHS provides more uniform enrichment over the entire polarity range for odor compounds in aqueous samples. FEDHS at 80°C using 3 L of purge gas allows complete vaporization of 100 μL of an aqueous sample, and trapping and drying it in an adsorbent packed tube, while providing high recoveries (85-103%) of the 18 model odor compounds (water solubility at 25°C: log0.54-5.65 mg L⁻¹, vapor pressure at 25°C: 0.011-3.2 mm Hg) and leaving most of the low volatile matrix behind. The FEDHS-GC-MS method showed good linearity (r²>0.9909) and high sensitivity (limit of detection: 0.21-5.2 ng mL⁻¹) for the model compounds even with the scan mode in the conventional MS. The feasibility and benefit of the method was demonstrated with analyses of key odor compounds including hydrophilic and less volatile characteristics in beverages (whiskey and green tea). In a single malt whiskey sample, phenolic compounds including vanillin could be determined in the range of 0.92-5.1 μg mL⁻¹ (RSDfuraneol, indole, maltol, and pyrazine congeners) were determined in the range of 0.21-110 ng mL⁻¹ (RSD<10%, n=6). Copyright © 2012 Elsevier B.V. All rights reserved.

  4. Calculation of thermal neutron self-shielding correction factors for aqueous bulk sample prompt gamma neutron activation analysis using the MCNP code

    International Nuclear Information System (INIS)

    Nasrabadi, M.N.; Jalali, M.; Mohammadi, A.

    2007-01-01

    In this work thermal neutron self-shielding in aqueous bulk samples containing neutron absorbing materials is studied using bulk sample prompt gamma neutron activation analysis (BSPGNAA) with the MCNP code. The code was used to perform three dimensional simulations of a neutron source, neutron detector and sample of various material compositions. The MCNP model was validated against experimental measurements of the neutron flux performed using a BF 3 detector. Simulations were performed to predict thermal neutron self-shielding in aqueous bulk samples containing neutron absorbing solutes. In practice, the MCNP calculations are combined with experimental measurements of the relative thermal neutron flux over the sample's surface, with respect to a reference water sample, to derive the thermal neutron self-shielding within the sample. The proposed methodology can be used for the determination of the elemental concentration of unknown aqueous samples by BSPGNAA where knowledge of the average thermal neutron flux within the sample volume is required

  5. Determination of 241Am and 244Cm in environmental samples

    International Nuclear Information System (INIS)

    Bonino, N.O.; Grinman, A.D.R.; Serdeiro, N.H.

    1998-01-01

    The present technique describes a method to separate, purify and measure low levels of americium and curium in different environmental samples such as sediments, soils, water, vegetables, and air filters. The determination of radionuclides in theses environmental matrices have analytical problems, since a simple method doesn't exist for the purification, which is indispensable for its later measuring alpha spectrometry. The developed technique consist on taking an aliquot of the sample to analyze, to add tracer as americium 243 and curium 242, and to dissolve the matrix in a such way to have a clear solution. For the isolation of the americium and curium of the other actinides ar used as separation techniques: precipitation with Fe 3+ , anionic and cationic exchange, and extraction with a appropriate organic solvent. The purification of the americium and curium is followed by the electrodeposition habitually used. The measurement is carried out by alpha spectrometry with a detector of implanted ion. The detection limit for this techniques is of 0,002 Bq/l or 0,2 mBq in the case of filters. (author)

  6. Comparison of needle concentrator with SPME for GC determination of benzene, toluene, ethylbenzene, and xylenes in aqueous samples

    Energy Technology Data Exchange (ETDEWEB)

    Prikryl, P.; Sevcik, J. [Charles Univ., Prague (Czech Republic). Dept. of Analytical Chemistry; Kubinec, R.; Jurdakova, H.; Ostrovsky, I.; Sojak, L. [Comenius Univ., Bratislava (Slovakia). Chemical Inst.; Berezkin, V. [Russian Academy of Sciences, Moscow (Russian Federation). A.V. Topchiev Inst. of Petrochemical Synthesis

    2006-07-15

    A method of solventless extraction of volatile organic compounds from aqueous samples has been developed and validated. A new arrangement in which the internal volume of a needle capillary adsorption trap is completely filled with Porapak Q, as adsorbent material, and wet alumina, as a source of desorptive water vapor flow, is presented. The device has been used for head-space sampling of benzene, toluene, ethylbenzene, and xylenes (BTEX) from water samples and compared with solid-phase microextraction. Under the same sampling conditions the analytical characteristics of the device for the BTEX compounds are better than those of solid-phase microextraction. Limits of detection and quantification are below 0.5 {mu} g L{sup -1}. (orig.)

  7. Vancomycin-resistant enterococci (VRE) in meat and environmental samples.

    Science.gov (United States)

    Messi, Patrizia; Guerrieri, Elisa; de Niederhäusern, Simona; Sabia, Carla; Bondi, Moreno

    2006-03-15

    We investigated the spread of vancomycin-resistant enterococci (VRE) in strains from meat and environmental samples and the location of glycopeptide-resistance determinants in VanA isolates. VRE and VSE (vancomycin-sensitive enterococci) resistance patterns to six antimicrobials were also evaluated. A total of 59 meat isolates (35%) and 119 environmental isolates (26.5%) were glycopeptide resistant enterococci. In particular, 10.7% meat isolates belonged to the VanA, 8.3% to VanB and 16% to VanC phenotypes. Environmental samples presented 0.7% VanA, 14.5% VanB, and 11.4% VanC strains. Evident differences were not observed among the resistance patterns of VRE and VSE isolates. Neither an important difference was observed comparing the resistance patterns in enterococci from meat and environment. In particular a low incidence of beta-lactamic resistant strains was found, whereas high rates of resistance were observed for streptomycin (85.7% and 92.8%), kanamycin (79.7% and 96%) and gentamycin (85.1% and 91.7%). An intermediate rate of resistant bacteria emerged for erythromycin (35.1% and 10.5%). All VanA isolates independent of origin had more plasmids with different molecular weights. PCR amplification of the 732 bp fragment in plasmids from the VanA strains confirmed affiliation to the vanA gene cluster and the extrachromosomal location of the glycopeptide-resistance determinants. Our study suggests that food and environment play a potential role as reservoirs of resistance determinants, prompting the need to undertake epidemiological and molecular studies to evaluate the mobility of these genes.

  8. Uniform field loop-gap resonator and rectangular TEU02 for aqueous sample EPR at 94 GHz

    Science.gov (United States)

    Sidabras, Jason W.; Sarna, Tadeusz; Mett, Richard R.; Hyde, James S.

    2017-09-01

    In this work we present the design and implementation of two uniform-field resonators: a seven-loop-six-gap loop-gap resonator (LGR) and a rectangular TEU02 cavity resonator. Each resonator has uniform-field-producing end-sections. These resonators have been designed for electron paramagnetic resonance (EPR) of aqueous samples at 94 GHz. The LGR geometry employs low-loss Rexolite end-sections to improve the field homogeneity over a 3 mm sample region-of-interest from near-cosine distribution to 90% uniform. The LGR was designed to accommodate large degassable Polytetrafluorethylen (PTFE) tubes (0.81 mm O.D.; 0.25 mm I.D.) for aqueous samples. Additionally, field modulation slots are designed for uniform 100 kHz field modulation incident at the sample. Experiments using a point sample of lithium phthalocyanine (LiPC) were performed to measure both the uniformity of the microwave magnetic field and 100 kHz field modulation, and confirm simulations. The rectangular TEU02 cavity resonator employs over-sized end-sections with sample shielding to provide an 87% uniform field for a 0.1 × 2 × 6 mm3 sample geometry. An evanescent slotted window was designed for light access to irradiate 90% of the sample volume. A novel dual-slot iris was used to minimize microwave magnetic field perturbations and maintain cross-sectional uniformity. Practical EPR experiments using the application of light irradiated rose bengal (4,5,6,7-tetrachloro-2‧,4‧,5‧,7‧-tetraiodofluorescein) were performed in the TEU02 cavity. The implementation of these geometries providing a practical designs for uniform field resonators that continue resonator advancements towards quantitative EPR spectroscopy.

  9. Heavy-metal-induced Inhibition of Aspergillus niger nitrate reductase: Applications for Rapid Contaminant Detection in Aqueous Samples

    Energy Technology Data Exchange (ETDEWEB)

    Apel, William Arnold; Aiken, Abigail Marie; Peyton, Brent Michael; Petersen, James N.

    2003-03-01

    Enzyme inhibition assays have the potential to rapidly screen and identify heavy metals in environmental samples. Inhibition of nitrate reductase (NR) was examined as a method for detecting toxic metals. The activity of NR (EC 1.6.6.2) from Aspergillus niger was assayed as a function of metal concentration in the presence of Cd2+, Cr3+, Cr6+, Cu2+, Ni2+, Pb2+, and Zn2+. NR exhibited sensitivity to these metals at concentrations below 10 µM. Various buffers were screened for their ability to protect NR activity from metal inhibition, and 3-(N-morpholino) propanesulfonic acid (MOPS) was selected as the buffering system for the NR assays as it exhibited the least interference with metal inhibition, thus providing increased assay sensitivity. The hypothesis that chelating agents could prevent the inhibition of NR activity by metal ions was also tested. Results indicated that 10 mM ethylenediaminetetraacetic acid (EDTA) could protect NR activity from inhibition by Cr3+, Cu2+, Cd2+, Ni2+, and Zn2+ at concentrations below 100 µM, but that the EDTA had no effect on NR inhibition by Cr6+. An amount of 10 mM nitrilotriacetic acid (NTA) prevented NR inhibition by Cd2+, Cu2+, Ni2+, Pb2+, and Zn2+ at metal concentrations below 100 µM. However, 10 mM NTA was unable to protect the enzyme from inhibition by either Cr3+ or Cr6+. These results indicated that through specific metal chelation, a NR-based method for individually quantifying Cr3+ and Cr6+ species in aqueous solutions could be developed. The ability to restore activity to NR which been previously inhibited by exposure to 100 µM Pb2+, Cd2+, Zn2+, Cu2+, and Cr3+ was explored to determine whether NR activity could be recovered by EDTA additions for use in consecutive metal inhibition assays. The results showed NR activity could not be regained after exposure to Cr3+ or Cu2+, but did partially recover activity after Cd2+, Pb2+, and Zn2+ exposure.

  10. Multi-analyte approach for the determination of ng L{sup -1} levels of steroid hormones in unidentified aqueous samples

    Energy Technology Data Exchange (ETDEWEB)

    Noppe, H. [Ghent University, Faculty of Veterinary Medicine, Research group of Veterinary Public Health and Zoonoses, Laboratory of Chemical Analysis, Salisburylaan 133, B-9820 Merelbeke (Belgium)]. E-mail: Herlinde.Noppe@UGent.be; Verheyden, K. [Ghent University, Faculty of Veterinary Medicine, Research group of Veterinary Public Health and Zoonoses, Laboratory of Chemical Analysis, Salisburylaan 133, B-9820 Merelbeke (Belgium); Gillis, W. [Federal Agency for the Safety of the Food Chain, WTC III, Simon Bolivarlaan 30, B-1000 Brussels (Belgium); Courtheyn, D. [Federal Feed and Food Laboratory, Braemkasteelstraat 59, B-9050 Ghent (Belgium); Vanthemsche, P. [Federal Agency for the Safety of the Food Chain, WTC III, Simon Bolivarlaan 30, B-1000 Brussels (Belgium); De Brabander, H.F. [Ghent University, Faculty of Veterinary Medicine, Research group of Veterinary Public Health and Zoonoses, Laboratory of Chemical Analysis, Salisburylaan 133, B-9820 Merelbeke (Belgium)

    2007-03-14

    Since the 1970s, many analytical methods for the detection of illegal growth promoters, such as thyreostats, anabolics, {beta}-agonists and corticosteroids have been developed for a wide range of matrices of animal origin, including meat, fat, organ tissue, urine and faeces. The aim of this study was to develop an analytical method for the determination of ng L{sup -1} levels of estrogens, gestagens, androgens (EGAs) and corticosteroids in aqueous preparations (i.e. drinking water, drinking water supplements), commercially available on the 'black' market. For this, extraction was performed with Bakerbond C{sub 18} speedisk, a technique commonly used in environmental analysis. After fractionation, four fractions were collected using a methanol:water gradient program. Gas chromatography coupled to electron impact multiple mass spectrometry (GC-EI-MS{sup 2}) screening for the EGAs was carried out on the derivatized extracts. For the detection of corticosteroids, gas chromatography coupled to negative chemical ionization mass spectrometry (GC-NCI-MS) was used after oxidation of the extracts. Confirmation was done by liquid chromatography coupled to electrospray ionization multiple mass spectrometry (LC-ESI-MS{sup 2}). The combined use of GC and LC coupled to MS enabled the identification and quantification of anabolics and corticosteroids at the low ng L{sup -1} level. This study demonstrated the occurrence of both androgens and corticosteroids in different commercial aqueous samples.

  11. Comparison of DNA preservation methods for environmental bacterial community samples

    Science.gov (United States)

    Gray, Michael A.; Pratte, Zoe A.; Kellogg, Christina A.

    2013-01-01

    Field collections of environmental samples, for example corals, for molecular microbial analyses present distinct challenges. The lack of laboratory facilities in remote locations is common, and preservation of microbial community DNA for later study is critical. A particular challenge is keeping samples frozen in transit. Five nucleic acid preservation methods that do not require cold storage were compared for effectiveness over time and ease of use. Mixed microbial communities of known composition were created and preserved by DNAgard™, RNAlater®, DMSO–EDTA–salt (DESS), FTA® cards, and FTA Elute® cards. Automated ribosomal intergenic spacer analysis and clone libraries were used to detect specific changes in the faux communities over weeks and months of storage. A previously known bias in FTA® cards that results in lower recovery of pure cultures of Gram-positive bacteria was also detected in mixed community samples. There appears to be a uniform bias across all five preservation methods against microorganisms with high G + C DNA. Overall, the liquid-based preservatives (DNAgard™, RNAlater®, and DESS) outperformed the card-based methods. No single liquid method clearly outperformed the others, leaving method choice to be based on experimental design, field facilities, shipping constraints, and allowable cost.

  12. Aqueous Two-Phase Systems: A New Approach for the Determination of Brilliant Blue FCF in Water and Food Samples

    Directory of Open Access Journals (Sweden)

    Sabah Shiri

    2013-01-01

    Full Text Available A novel, simple, and more sensitive spectrophotometric procedure has been developed for the determination of brilliant blue FCF in water and food samples by an aqueous two-phase system (ATPS. In this method, adequate amount of polyethylene glycol/ sodium carbonate (PEG-4000/Na2CO3 was added to aqueous solution for formation of a homogeneous solution. To the mixture solution, suitable amount of Na2CO3 was added, the mixture solution was shaken until the salt was dissolved, and then it was separated into two clear phases easily and rapidly. The target analyte in the water sample was extracted into the polyethylene glycol phase. After extraction, measuring the absorbance at 634 nm was done. The effects of different parameters such as polyethylene glycol (type and concentration, pH, salt (type and amount, centrifuge time, and temperature on the ATPS of dye was investigated and optimum conditions were established. Linear calibration curves were obtained in the range of 0.25–750 ng/mL for brilliant blue FCF under optimum conditions. Detection limit based on three times the standard deviation of the blank (3Sb was 0.12 ng/mL. The relative standard deviation (RSD for 400 ng/mL was 3.14%. The method was successfully applied to the determination of brilliant blue FCF in spiked samples with satisfactory results. The relative recovery was between 96.0 and 102.2%.

  13. Radioactive kryptonates in the analysis of environmental samples

    International Nuclear Information System (INIS)

    Tolgyessy, J.

    1986-01-01

    The term ''radioactive Kryptonates'' is used for substances into which atoms or ions of the radioactive nuclide 85 Kr are incorporated. The basis of the use of radioactive Kryptonates in analytical chemistry is that during a chemical reaction the crystalline lattice of the kryptonated carrier is destroyed, the carrier consumed, and the radioactive krypton released (radio-release method). Analysis can be made with a calibration curve or by comparison with a standard. Radio-release methods with the aid of radioactive Kryptonates as analytical reagents are very useful for the analysis of environmental samples, e.g. for the determination of air pollutants (ozone, sulphur dioxide, fluorine, hydrogen fluoride, mercury); and water pollutants (oxygen, dichromate, vanadium, hydrochloric acid, sulphur dioxide). (author)

  14. Gamma-spectrometry of extended sources for analysing environmental samples

    International Nuclear Information System (INIS)

    Jarosievitz, B.

    1996-01-01

    Measurements of the environmental activity concentration by gamma spectrometers require the determination of the full-energy-peak efficiency as a function of photon energy over the detector range. This can be done by experiments or by calculation. For simple cases, experiments are straightforward, but if the decay scheme is complex, cascade effects modify detection efficiency. Also, actual detection efficiency depends on the detection geometry. All these effects are treated as corrections or modifications of the simple value cases which are especially relevant when applied to large volume of environmental samples. In this thesis calculations are made, using the GEANT MC program, for realistic experimental situations that have been performed, and these calculations are validated. The calculational and experimental results have been compared, and if it proves to be satisfactory, the results can be relied on even for cases when no direct experimental observation is possible. The general problems of gamma spectroscopy and correction problems are discussed. The two main tools, the experimental setup and the simulation program are described. A careful checking of the simulation results and the consequences are presented. (R.P.)

  15. Methods for parasitic protozoans detection in the environmental samples

    Directory of Open Access Journals (Sweden)

    Skotarczak B.

    2009-09-01

    Full Text Available The environmental route of transmission of many parasitic protozoa and their potential for producing large numbers of transmissive stages constitute persistent threats to public and veterinary health. Conventional and new immunological and molecular methods enable to assess the occurrence, prevalence, levels and sources of waterborne protozoa. Concentration, purification, and detection are the three key steps in all methods that have been approved for routine monitoring of waterborne cysts and oocysts. These steps have been optimized to such an extent that low levels of naturally occurring (oocysts of protozoan can be efficiently recovered from water. Ten years have passed since the United States Environmental Protection Agency (USEPA introduced the 1622 and 1623 methods and used them to concentrate and detect the oocysts of Cryptosporidium and cysts of Giardia in water samples. Nevertheless, the methods still need studies and improvements. Pre-PCR processing procedures have been developed and they are still improved to remove or reduce the effects of PCR inhibitors. The progress in molecular methods allows to more precise distinction of species or simultaneous detection of several parasites, however, they are still not routinely used and need standardization. Standardized methods are required to maximize public health surveillance.

  16. New quantitative detection of pathogens in heterogeneous environmental samples

    Science.gov (United States)

    Lee, Eun-Hee; Wang, Xiaofang; Mitchell, Kristi; Chae, Seon-Ha; Son, Ahjeong

    2015-04-01

    Quantum dots and magnetic beads based genomic assay (NanoGene assay) has been developed for sensitive and inhibition resistant gene quantification to achieve in-situ bacteria monitoring in environmental samples. In this study, eaeA gene of pathogenic E. coli O157:H7 was quantified. The result demonstrated the excellent sensitivity (i.e., limit of detection: 87 gene copies for dsDNA and 890 zeptomolar for ssDNA) in the presence of nonspecific microbial populations (Kim et al., 2010; 2011a). The feasibility of the developed gene quantification for non-laboratory environment usage (in-situ use) was investigated. Therefore, DNA hybridization was achieved at ambient temperature and minimum agitation, and the analysis was completed within hours. Most importantly, the NanoGene assay demonstrated the resistance to the presence of naturally occurring inhibitors (humic acids, cations) and residual reagents (surfactants, alcohols) from DNA extraction (Kim et al., 2011b). The assay was also applied to humic acids laden soils (7 types of soils with various amount of organic matters) and successfully quantified 105 to 108 CFU of E. coli O157:H7 per gram soil (R2 = 0.99). The results indicate that the presented NanoGene assay is suitable for further development as an in-situ bacteria monitoring method for working with heterogeneous environmental samples (Wang et al., 2013). Another aspect of the method is to transform the NanoGene assay into a portable device that can be used as a pathogenic bacteria detector in environment. The project consisted of the first inline fluidic components development and characterization as well as the first integration effort on a briefcase platform for the in-situ pathogen detection system (IPDS) (Mitchell et al., 2014). Our long term vision is to further miniaturize the briefcase platform implementation of the IPDS and to commercialize the handheld version of the IPDS.

  17. [DOE method for evaluating environmental and waste management samples: Revision 1, Addendum 1

    International Nuclear Information System (INIS)

    Goheen, S.C.

    1995-04-01

    The US Dapartment of Energy's (DOE's) environmental and waste management (EM) sampling and analysis activities require that large numbers of samples be analyzed for materials characterization, environmental surveillance, and site-remediation programs. The present document, DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods), is a supplemental resource for analyzing many of these samples

  18. [DOE method for evaluating environmental and waste management samples: Revision 1, Addendum 1

    Energy Technology Data Exchange (ETDEWEB)

    Goheen, S.C.

    1995-04-01

    The US Dapartment of Energy`s (DOE`s) environmental and waste management (EM) sampling and analysis activities require that large numbers of samples be analyzed for materials characterization, environmental surveillance, and site-remediation programs. The present document, DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods), is a supplemental resource for analyzing many of these samples.

  19. Determination of 228Th, 230Th, and 232Th in environmental samples from uranium mining and milling operations

    International Nuclear Information System (INIS)

    Durham, R.W.; Joshi, S.R.

    1979-01-01

    A method is described for the determination of 228 Th, 230 Th, and 232 Th in environmental samples from uranium mining and milling operations. The analytical procedure is based on the direct determination of 228 Th in the sample by high resolution γ-spectrometry followed by extraction and purification of the thorium fraction using high molecular weight amines and an anion-exchange technique, respectively, prior to α-spectrometry to determine isotopic ratios. The lowest level of detection for each thorium isotope is 0.01 pCi/g for solid samples and 20 pCi/l for aqueous samples. Replicate analyses of a typical mine waste stream gave a standard deviation of +-3% for 228 Th. Standard deviations of the 230 Th and 232 Th increased to +-11% apparently due to traces of 210 Po interfering in the α-spectrometry. (author)

  20. Nonequilibrium hollow-fiber liquid-phase microextraction with in situ derivatization for the measurement of triclosan in aqueous samples by gas chromatography-mass spectrometry.

    Science.gov (United States)

    Zhao, Ru-Song; Yuan, Jin-Peng; Li, Hai-Fang; Wang, Xu; Jiang, Ting; Lin, Jin-Ming

    2007-04-01

    Hollow-fiber liquid-phase microextraction (HF-LPME), a relatively new sample preparation technique, has attracted much interest in the field of environmental analysis. In the current study, a novel method based on hollow-fiber liquid-phase microextraction with in situ derivatization and gas chromatography-mass spectrometry for the measurement of triclosan in aqueous samples is described. Hollow-fiber liquid-phase microextraction conditions such as the type of extraction solvent, the stirring rate, the volume of derivatizing reagent, and the extraction time were investigated. When the conditions had been optimized, the linear range was found to be 0.05-100 microg l(-1) for triclosan, and the limit of detection to be 0.02 microg l(-1). Tap water and surface water samples collected from our laboratory and Wohushan reservoir, respectively, were successfully analyzed using the proposed method. The recoveries from the spiked water samples were 83.6 and 114.1%, respectively; and the relative standard deviation (RSD) at the 1.0 microg l(-1) level was 6.9%.

  1. Dioxin-like activity of environmental compounds in human blood and environmental samples

    DEFF Research Database (Denmark)

    Long, Manhai; Bonefeld-Jørgensen, Eva Cecilie

    2012-01-01

    Dioxins and dioxin-like (DL) compounds are some of the most toxic chemicals being highly persistent in the environment. The toxicological effects of dioxins are mediated via the aryl hydrocarbon receptor (AhR). Compounds of diverse structure and lipophility can bind and activate AhR. The AhR tran...... a cost-effective and integrated screening tool for measurement of the DL-activity in human, environmental and commercial samples....

  2. Laser heating of aqueous samples on a micro-optical-electro-mechanical system

    Science.gov (United States)

    Beer, Neil Reginald; Kennedy, Ian

    2013-02-05

    A system of heating a sample on a microchip includes the steps of providing a microchannel flow channel in the microchip; positioning the sample within the microchannel flow channel, providing a laser that directs a laser beam onto the sample for heating the sample; providing the microchannel flow channel with a wall section that receives the laser beam and enables the laser beam to pass through wall section of the microchannel flow channel without being appreciably heated by the laser beam; and providing a carrier fluid in the microchannel flow channel that moves the sample in the microchannel flow channel wherein the carrier fluid is not appreciably heated by the laser beam.

  3. Detection of Naegleria species in environmental samples from Peninsular Malaysia.

    Directory of Open Access Journals (Sweden)

    Init Ithoi

    Full Text Available In Malaysia, researchers and medical practitioners are unfamiliar with Naegleria infections. Thus little is known about the existence of pathogenic Naegleria fowleri, and the resultant primary amoebic meningoencephalitis (PAM is seldom included in the differential diagnosis of central nervous system infections. This study was conducted to detect the presence of Naegleria species in various environmental samples.A total of 41 Naegleria-like isolates were isolated from water and dust samples. All these isolates were subjected to PCR using two primer sets designed from the ITS1-ITS2 regions. The N. fowleri species-specific primer set failed to produce the expected amplicon. The Naegleria genus-specific primers produced amplicons of 408 bp (35, 450 bp (2, 457 bp (2 or 381 bp (2 from all 41 isolates isolated from aquatic (33 and dust (8 samples. Analysis of the sequences from 10 representative isolates revealed that amplicons with fragments 408, 450 and 457 bp showed homology with non-pathogenic Naegleria species, and 381 bp showed homology with Vahlkampfia species. These results concurred with the morphological observation that all 39 isolates which exhibited flagella were Naegleria, while 2 isolates (AC7, JN034055 and AC8, JN034056 that did not exhibit flagella were Vahlkampfia species.To date, pathogenic species of N. fowleri have not been isolated from Malaysia. All 39 isolates that produced amplicons (408, 450 and 457 bp from the genus-specific primers were identified as being similar to nonpathogenic Naegleria. Amplicon 408 bp from 5 representative isolates showed 100% and 99.7% identity to Naegleria philippinensis isolate RJTM (AM167890 and is thus believed to be the most common species in our environment. Amplicons 450 bp and 457 bp were respectively believed to be from 2 new species of Naegleria, since representative isolates showed lower homology and had a longer base pair length when compared to the reference species in the Genbank

  4. Water pollution screening by large-volume injection of aqueous samples and application to GC/MS analysis of a river Elbe sample

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, S.; Efer, J.; Engewald, W. [Leipzig Univ. (Germany). Inst. fuer Analytische Chemie

    1997-03-01

    The large-volume sampling of aqueous samples in a programmed temperature vaporizer (PTV) injector was used successfully for the target and non-target analysis of real samples. In this still rarely applied method, e.g., 1 mL of the water sample to be analyzed is slowly injected direct into the PTV. The vaporized water is eliminated through the split vent. The analytes are concentrated onto an adsorbent inside the insert and subsequently thermally desorbed. The capability of the method is demonstrated using a sample from the river Elbe. By means of coupling this method with a mass selective detector in SIM mode (target analysis) the method allows the determination of pollutants in the concentration range up to 0.01 {mu}g/L. Furthermore, PTV enrichment is an effective and time-saving method for non-target analysis in SCAN mode. In a sample from the river Elbe over 20 compounds were identified. (orig.) With 3 figs., 2 tabs.

  5. Microwave heating of aqueous samples on a micro-optical-electro-mechanical system

    Science.gov (United States)

    Beer, Neil Reginald

    2015-03-03

    Apparatus for heating a sample includes a microchip; a microchannel flow channel in the microchip, the microchannel flow channel containing the sample; a microwave source that directs microwaves onto the sample for heating the sample; a wall section of the microchannel flow channel that receives the microwaves and enables the microwaves to pass through wall section of the microchannel flow channel, the wall section the microchannel flow channel being made of a material that is not appreciably heated by the microwaves; a carrier fluid within the microchannel flow channel for moving the sample in the microchannel flow channel, the carrier fluid being made of a material that is not appreciably heated by the microwaves; wherein the microwaves pass through wall section of the microchannel flow channel and heat the sample.

  6. APPLICATION OF STIR BAR SORPTIVE EXTRACTION TO ANALYSIS OF VOLATILE AND SEMIVOLATILE ORGANIC CHEMICALS OF POTENTIAL CONCERN IN SOLIDS AND AQUEOUS SAMPLES FROM THE HANFORD SITE

    International Nuclear Information System (INIS)

    Frye, J.M.; Kunkel, J.M.

    2009-01-01

    Stir bar sorptive extraction was applied to aqueous and solid samples for the extraction and analysis of organic compounds from the Hanford chemicals of potential concern list, as identified in the vapor data quality objectives. The 222-S Laboratory analyzed these compounds from vapor samples on thermal desorption tubes as part of the Hanford Site industrial hygiene vapor sampling effort

  7. Using SPE-LC-ESI-MS/MS Analysis to Assess Disperse Dyes in Environmental Water Samples.

    Science.gov (United States)

    Zocolo, Guilherme Julião; Pilon dos Santos, Glauco; Vendemiatti, Josiane; Vacchi, Francine Inforçato; Umbuzeiro, Gisela de Aragão; Zanoni, Maria Valnice Boldrin

    2015-09-01

    We have optimized an SPE-LC-ESI-MS/MS method and used it to monitor disperse azo dyes in environmental aquatic samples. Calibration curves constructed for nine disperse dyes-Red 1, Violet 93, Blue 373, Orange 1, Orange 3, Orange 25, Yellow 3, Yellow 7 and Red 13-in aqueous solution presented good linearity between 2.0 and 100.0 ng mL(-1). The method provided limits of detection and quantification around 2.0 and 8.0 ng L(-1), respectively. For dyes at concentrations of 25.0 ng mL(-1), the intra- and interday analyses afforded relative standard deviation lower than 6 and 13%, respectively. The recovery values obtained for each target analyte in Milli-Q water, receiving waters and treated water samples spiked with the nine studied dyes at concentrations of 8.0, 25.0 and 50.0 ng L(-1) (n = 3) gave average recoveries greater than 70%, with RSD dyes Disperse Red 1, Disperse Blue 373 and Disperse Violet 93 at concentrations ranging from 84 to 3452 ng L(-1) in the treated effluent (TE), affluent and points collected upstream and downstream of the drinking water treatment plant of a textile dye industry in Brazil. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Aqueous chloride stress corrosion cracking of titanium - A comparison with environmental hydrogen embrittlement

    Science.gov (United States)

    Nelson, H. G.

    1974-01-01

    The physical characteristics of stress corrosion cracking of titanium in an aqueous chloride environment are compared with those of embrittlement of titanium by a gaseous hydrogen environment in an effort to help contribute to the understanding of the possible role of hydrogen in the complex stress corrosion cracking process. Based on previous studies, the two forms of embrittlement are shown to be similar at low hydrogen pressures (100 N/sq m) but dissimilar at higher hydrogen pressures. In an effort to quantify this comparison, tests were conducted in an aqueous chloride solution using the same material and test techniques as had previously been employed in a gaseous hydrogen environment. The results of these tests strongly support models based on hydrogen as the embrittling species in an aqueous chloride environment.

  9. Results of the Interlaboratory Exercise CNS/CIEMAT-04 Among Environmental Radioactivity Laboratories (Aqueous Solution)

    International Nuclear Information System (INIS)

    Romero Gonzalez, M. L.; Barrera Izquierdo, M.

    2004-01-01

    The document describes the outcome of the CSN/CIEMAT-04 interlaboratory test comparison among environmental radioactivity laboratories. The exercise was organised according to the ISO-43 and the ISO/IUPAC/AOAC Harmonised Protocol for the proficiency testing of analytical laboratories. Following the issue of the European Community Drinking Water Directive 98/83/EC concerning the quality of water for human consumption, the last inter-comparison exercise was organised by using a water sample, in an attempt to evaluate the performance of the laboratories analysing the required radioactivity parameters (H-3, gross alpha and beta activity and residual beta). The sample (a synthetic drinking water), was prepared at the National Laboratory for Ionising Radiation's Standards (CIEMAT), and contained the following radionuclides ''241 Am, ''239+240 Pu, ''90Sr, ''137 Cs, ''3 H y ''40 K. The results of the exercise were computed for 38 participating laboratories, and their analytical performance was assessed using the z-score approach. Robust statistics of the participant's results was applied to obtain the median and standard deviation, including suspected outliers. The exercise has revealed and homogeneous behaviour of laboratories, being statistical parameters from the results close to the reference values. A raised percentage os satisfactory laboratory performance has been obtained for gross alpha, gross beta and residual beta: 85, 97 and 87% respectively. The study has shown that participant laboratories perform radioactive determinations in drinking water samples with satisfactory quality levels. (Author) 16 refs

  10. Molecular Signatures of Methanogens in Cultures and Environmental Samples

    Science.gov (United States)

    Summons, R. E.; Embaye, T.; Jahnke, L. L.; Baumgartner, M.

    2002-12-01

    The core lipids of methanogens comprise C20 and C40 isoprenoid chains, linked through ether bonds to glycerol. Additional structural diversity is encoded into the polar head groups that are attached to the glycerol ether cores. These compounds are potentially very useful as taxonomic markers in microbial mats and other environmental samples while the nature of the hydrocarbon chains provide a means to identify methanogenic inputs to ancient sediments. The structural diversity of methanogen polar lipids is most valuable when it can be directly correlated to 16S rRNA phylogeny. On the other hand, this diversity can also leads to analytical challenges because there is no single approach that works for all structural types. While some intact methanogen lipids have been identified using mass spectrometry and NMR spectroscopy, the most common means of analysing the lipid cores involves cleavage of the ether bonds using HI and subsequent reduction of the alkyl iodides to hydrocarbons with LiAlH4. One class of methanogenic lipids, the 3?-hydroxyarchaeols, escaped detection for some years because strong acid treatments in the analysis protocols destroyed hydroxyl-containing isoprenoid chains. We have been systematically re-examining the lipids of methanogens, using milder procedures involving weak acid hydrolysis of polar head groups, derivatisation to form trimethylsilyl ethers and analysis by GC-MS. As well as archaeol, sn-2- and sn-3-hydroxyarchaeol, we have tentatively identified a dihydroxyarchaeol in several Methanococcus sp. For Methanococcus thermolithotrophicus an analysis of the total lipid extracts using BBr3 as an ether cleavage reagent followed by LiBEt3H, reduction revealed a very complex mixture consisting of phytane, phytenes, biphytane, biphytenes and a suite of related alcohols. The latter compounds were analysed by GC-MS as their trimethylsilyl ethers and found to comprise a mixture tentatively identified as phytan-N-ol and biphytan-N-ol where N= 3 or 7

  11. Determination of Ra in environmental samples by. alpha. -particle spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Hancock, G.J.; Martin, P. (Alligator Rivers Region Research Inst., Jabiru, N.T. (Australia))

    1991-01-01

    A method of determining Ra isotopes by {alpha}-particle spectrometry using {sup 225}Ra as a yield tracer has been developed. Radium is coprecipitated with lead sulphate, purified using ion exchange techniques, and electrodeposited from an aqueous/ethanol solution. The procedure can be easily completed in 1 day. Tracer recoveries are typically 80%, and the resolution obtained is typically 40 keV FWHM. (author).

  12. Capability of environmental sampling to detect undeclared cask openings

    International Nuclear Information System (INIS)

    Beckstead, L.W.; Efurd, D.W.; Hemberger, P.H.; Abhold, M.E.; Eccleston, G.W.

    1997-01-01

    The goal of this study is to determine the signatures that would allow monitors to detect diversion of nuclear fuel (by a diverter) from a storage area such as a geological repository. Due to the complexity of operations surrounding disposal of spent nuclear fuel in a geologic repository, there are several places that a diversion of fuel could take place. After the canister that contains the fuel rods is breached, the diverter would require a hot cell to process or repackage the fuel. A reference repository and possible diversion scenarios are discussed. When a canister is breached, or during reprocessing to extract nuclear weapons material (primarily Pu), several important isotopes or signatures including tritium, 85 Kr, and 129 I are released to the surrounding environment and have the potential for analysis. Estimates of release concentrations of the key signatures from the repository under a hypothetical diversion scenario are presented and discussed. Gas analysis data collected from above-ground storage casks at Idaho National Engineering and Environmental Laboratory (INEEL) Test Area North (TAN) are included and discussed in the report. In addition, LANL participated in gas sampling of one TAN cask, the Castor V/21, in July 1997. Results of xenon analysis from the cask gas sample are presented and discussed. The importance of global fallout and recent commercial reprocessing activities and their effects on repository monitoring are discussed. Monitoring and instrumental equipment for analysis of the key signature isotopes are discussed along with limits of detection. A key factor in determining if diversion activities are in progress at a repository is the timeliness of detection and analysis of the signatures. Once a clandestine operation is suspected, analytical data should be collected as quickly as possible to support any evidence of diversion

  13. Capability of environmental sampling to detect undeclared cask openings

    Energy Technology Data Exchange (ETDEWEB)

    Beckstead, L.W.; Efurd, D.W.; Hemberger, P.H.; Abhold, M.E.; Eccleston, G.W.

    1997-12-01

    The goal of this study is to determine the signatures that would allow monitors to detect diversion of nuclear fuel (by a diverter) from a storage area such as a geological repository. Due to the complexity of operations surrounding disposal of spent nuclear fuel in a geologic repository, there are several places that a diversion of fuel could take place. After the canister that contains the fuel rods is breached, the diverter would require a hot cell to process or repackage the fuel. A reference repository and possible diversion scenarios are discussed. When a canister is breached, or during reprocessing to extract nuclear weapons material (primarily Pu), several important isotopes or signatures including tritium, {sup 85}Kr, and {sup 129}I are released to the surrounding environment and have the potential for analysis. Estimates of release concentrations of the key signatures from the repository under a hypothetical diversion scenario are presented and discussed. Gas analysis data collected from above-ground storage casks at Idaho National Engineering and Environmental Laboratory (INEEL) Test Area North (TAN) are included and discussed in the report. In addition, LANL participated in gas sampling of one TAN cask, the Castor V/21, in July 1997. Results of xenon analysis from the cask gas sample are presented and discussed. The importance of global fallout and recent commercial reprocessing activities and their effects on repository monitoring are discussed. Monitoring and instrumental equipment for analysis of the key signature isotopes are discussed along with limits of detection. A key factor in determining if diversion activities are in progress at a repository is the timeliness of detection and analysis of the signatures. Once a clandestine operation is suspected, analytical data should be collected as quickly as possible to support any evidence of diversion.

  14. Aqueous sample from B-Plant, Tank 9-1. Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    Bell, K.E.

    1995-05-18

    Eight liquid samples were received from B-Plant Tank 9-1 in four lots of two samples each, for inorganic and organic analysis. This is the final report for the sampling and analysis effort; included are summary tables of the analytical and quality control data as well as all raw data. The analyses include pH, OH, inductively coupled plasma spectrography, ion chromatograph, total organic carbon, total inorganic carbon, and differential scanning calorimetry. Included are copies of the chain of custody and request for special analysis forms.

  15. A special core liner for sub-sampling of aqueous sediments

    Digital Repository Service at National Institute of Oceanography (India)

    Valsangkar, A.B.

    contamination. The sub-sampling was completed in ~30 min with the assistance of only one person (Figure 4). It was observed during the sub-sampling that no sample Figure 1. Rings/sections of 1 cm size from acrylic liner. Figure 2. Special... Nodules (S&E)’. The anonymous reviewer is thanked for helpful comments on the manuscript; Mr Pramod Pawaskar for preparing the drawings and Mahesh Mochemadkar for on-board photography during test operation. Assistance provided by Nelita Fernandes...

  16. Application of SIMS to the analysis of environmental samples

    International Nuclear Information System (INIS)

    Seyama, Haruhiko

    2003-01-01

    As an example of surface analysis of environmental samples, SIMS was applied to airborne particulates, fish otoliths (a calcareous ear-stone) and biotites (a rock-forming aluminosilicate mineral). Airborne particulates deposited on leaf surface were analyzed directly by fast atom bombardment (FAB)-SIMS using an O 2 primary neutral beam. Some metal elements, such as Pb, of aerosol origin could be detected. Local areas of a thin section of an otolith were analyzed by FAB-SIMS. Line scans and images of secondary ions revealed seasonal periodicity in Sr, Na and K concentrations in the otolith that corresponded to the annual band structure. Surface alteration of acid-treated and naturally weathered biotites was studied by SIMS depth profiling using an O - primary ion. The depth profile of the acid-treated biotite showed the formation of an altered surface layer rich in Si. In contrast a thick altered surface layer was not observed and Al was held on the surface under natural weathering

  17. Methods to maximise recovery of environmental DNA from water samples.

    Directory of Open Access Journals (Sweden)

    Rheyda Hinlo

    Full Text Available The environmental DNA (eDNA method is a detection technique that is rapidly gaining credibility as a sensitive tool useful in the surveillance and monitoring of invasive and threatened species. Because eDNA analysis often deals with small quantities of short and degraded DNA fragments, methods that maximize eDNA recovery are required to increase detectability. In this study, we performed experiments at different stages of the eDNA analysis to show which combinations of methods give the best recovery rate for eDNA. Using Oriental weatherloach (Misgurnus anguillicaudatus as a study species, we show that various combinations of DNA capture, preservation and extraction methods can significantly affect DNA yield. Filtration using cellulose nitrate filter paper preserved in ethanol or stored in a -20°C freezer and extracted with the Qiagen DNeasy kit outperformed other combinations in terms of cost and efficiency of DNA recovery. Our results support the recommendation to filter water samples within 24hours but if this is not possible, our results suggest that refrigeration may be a better option than freezing for short-term storage (i.e., 3-5 days. This information is useful in designing eDNA detection of low-density invasive or threatened species, where small variations in DNA recovery can signify the difference between detection success or failure.

  18. Environmental Assessment of Natural Radioactivity in Soil Samples

    Directory of Open Access Journals (Sweden)

    Ryuta Hazama

    2009-07-01

    Full Text Available The environmental impacts and hazards due to the unstoppable hot mud flow by the East Java ‘LUSI’ Mud Volcano are increasing since its unexpected eruption on May 29, 2006. Analysis should be undertaken, not only to examine its impact on human health and the environment, but also to explore the potential benefits of the mud flow. One may be able to tap the mud flow as a material source for brick and cement. Recently there has been great concern about the health risks associated with exposure to natural radioactivity present in soil and building materials all over the world. In this context, measurements for natural radioactive isotopes such as 238U and 232Th series, and 40K in mud samples were carried out using the HPGe (High-Purity Germanium detector to determine the re-usability of the mud. 226Ra, 232Th and 40K activity concentrations were found to be 13±1, 15±1 and 111±3 Bq/kg (1 Bq = 1 sec-1, respectively, and the corresponding activity index was found to be 0.16±0.02. These values were compared with previous data and our measured accuracy was improved by a factor of nine at the maximum. Radium equivalent activity, external and internal hazard indices, and annual effective dose equivalent were also evaluated and all were found to be within acceptable limits.

  19. Multi-elemental analysis of aqueous geochemical samples by quadrupole inductively coupled plasma-mass spectrometry (ICP-MS)

    Science.gov (United States)

    Wolf, Ruth E.; Adams, Monique

    2015-01-01

    Typically, quadrupole inductively coupled plasma-mass spectrometry (ICP-MS) is used to determine as many as 57 major, minor, and trace elements in aqueous geochemical samples, including natural surface water and groundwater, acid mine drainage water, and extracts or leachates from geological samples. The sample solution is aspirated into the inductively coupled plasma (ICP) which is an electrodeless discharge of ionized argon gas at a temperature of approximately 6,000 degrees Celsius. The elements in the sample solution are subsequently volatilized, atomized, and ionized by the ICP. The ions generated are then focused and introduced into a quadrupole mass filter which only allows one mass to reach the detector at a given moment in time. As the settings of the mass analyzer change, subsequent masses are allowed to impact the detector. Although the typical quadrupole ICP-MS system is a sequential scanning instrument (determining each mass separately), the scan speed of modern instruments is on the order of several thousand masses per second. Consequently, typical total sample analysis times of 2–3 minutes are readily achievable for up to 57 elements.

  20. In-tube extraction of volatile organic compounds from aqueous samples: an economical alternative to purge and trap enrichment.

    Science.gov (United States)

    Laaks, Jens; Jochmann, Maik A; Schilling, Beat; Schmidt, Torsten C

    2010-09-15

    A novel in-tube extraction device (ITEX 2) for headspace sampling was evaluated for GC/MS analysis of aqueous samples. Twenty compounds of regulatory and drinking water quality importance were analyzed, including halogenated hydrocarbons, BTEX compounds (benzene, toluene, ethylbenzene, xylenes), fuel oxygenates, geosmin, and 2-methylisoborneol. Five commercially available sorbent traps were compared for their compound specific extraction yield. On the basis of the results, a mixed bed trap was prepared and evaluated. The extraction parameters were optimized to yield maximum sensitivity within the time of a GC run, to avoid unnecessary downtime of the system. Method detection limits of 1-10 ng L(-1) were achieved for volatile organic compounds (VOCs), which is much lower than demands by regulatory limit values. The performance of the ITEX system is similar to that of purge and trap systems, but it requires lower sample volumes and is less prone to contamination, much simpler, more flexible, and affordable. Average relative standard deviations below 10% were achieved for all analytes, and recoveries from spiked tap water samples were between 90% and 103%, mostly. The extraction is nonexhaustive, removing a fraction of 7% to 55% of the target compounds, depending on the air-water partitioning coefficients. The method was also tested with nonsynthetic samples, including tap, pond, and reservoir water and different soft drinks.

  1. Ab Initio Molecular Dynamics Simulations of Amino Acids in Aqueous Solutions: Estimating pKa Values from Metadynamics Sampling.

    Science.gov (United States)

    Tummanapelli, Anil Kumar; Vasudevan, Sukumaran

    2015-09-17

    Changes in the protonation and deprotonation of amino acid residues in proteins play a key role in many biological processes and pathways. Here, we report calculations of the free-energy profile for the protonation-deprotonation reaction of the 20 canonical α amino acids in aqueous solutions using ab initio Car-Parrinello molecular dynamics simulations coupled with metadynamics sampling. We show here that the calculated change in free energy of the dissociation reaction provides estimates of the multiple pKa values of the amino acids that are in good agreement with experiment. We use the bond-length-dependent number of the protons coordinated to the hydroxyl oxygen of the carboxylic and the amine groups as the collective variables to explore the free-energy profiles of the Bronsted acid-base chemistry of amino acids in aqueous solutions. We ensure that the amino acid undergoing dissociation is solvated by at least three hydrations shells with all water molecules included in the simulations. The method works equally well for amino acids with neutral, acidic and basic side chains and provides estimates of the multiple pKa values with a mean relative error, with respect to experimental results, of 0.2 pKa units.

  2. Passive Dosing to Determine the Speciation of Hydrophobic Organic Chemicals in Aqueous Samples

    DEFF Research Database (Denmark)

    Birch, Heidi; Gouliarmou, V.; Lützhøft, Hans-Christian Holten

    2010-01-01

    A new analytical approach to determine the speciation of hydrophobic organic analytes is presented. The freely dissolved concentration in a sample is controlled by passive dosing from silicone (poly(dimethylsiloxane)), and the total sample concentration at equilibrium is measured. The free fraction...... is determined as the ratio between measured concentrations in pure water and sample. C-14-labeled fluoranthene served as model analyte, and total sample concentrations were easily measured by liquid scintillation counting. The method was applied to surface water, stormwater runoff, and wastewater....... In the untreated wastewater, 61% of the fluoranthene was bound to suspended solids, 28% was associated to dissolved organic matter, and 11% was freely dissolved, while in treated wastewater, the speciation was 16% bound to suspended solids, 4% bound to dissolved organic matter, and 80% freely dissolved. The free...

  3. Aqueous chloride stress corrosion cracking of titanium: A comparison with environmental hydrogen embrittlement

    Science.gov (United States)

    Nelson, H. G.

    1973-01-01

    The physical characteristics of stress corrosion cracking of titanium in an aqueous chloride environment are compared with those of embrittlement of titanium by a gaseous hydrogen environment in an effort to help contribute to the understanding of the possible role of hydrogen in the complex stress corrosion cracking process. Based on previous studies, the two forms of embrittlement are shown to be similar at low hydrogen pressures (100 N/sqm) but dissimilar at higher hydrogen pressures. In an effort to quantify this comparison, tests were conducted in an aqueous chloride solution using the same material and test techniques as had previously been employed in a gaseous hydrogen environment. The results of these tests strongly support models based on hydrogen as the embrittling species in an aqueous chloride environment. Further, it is shown that if hydrogen is the causal species, the effective hydrogen fugacity at the surface of titanium exposed to an aqueous chloride environment is equivalent to a molecular hydrogen pressure of approximately 10 N/sqm.

  4. Detection of Naegleria Species in Environmental Samples from Peninsular Malaysia

    Science.gov (United States)

    Ithoi, Init; Ahmad, Arine Fadzlun; Nissapatorn, Veeranoot; Lau, Yee Ling; Mahmud, Rohela; Mak, Joon Wah

    2011-01-01

    Background In Malaysia, researchers and medical practitioners are unfamiliar with Naegleria infections. Thus little is known about the existence of pathogenic Naegleria fowleri, and the resultant primary amoebic meningoencephalitis (PAM) is seldom included in the differential diagnosis of central nervous system infections. This study was conducted to detect the presence of Naegleria species in various environmental samples. Methods/Findings A total of 41 Naegleria-like isolates were isolated from water and dust samples. All these isolates were subjected to PCR using two primer sets designed from the ITS1-ITS2 regions. The N. fowleri species-specific primer set failed to produce the expected amplicon. The Naegleria genus-specific primers produced amplicons of 408 bp (35), 450 bp (2), 457 bp (2) or 381 bp (2) from all 41 isolates isolated from aquatic (33) and dust (8) samples. Analysis of the sequences from 10 representative isolates revealed that amplicons with fragments 408, 450 and 457 bp showed homology with non-pathogenic Naegleria species, and 381 bp showed homology with Vahlkampfia species. These results concurred with the morphological observation that all 39 isolates which exhibited flagella were Naegleria, while 2 isolates (AC7, JN034055 and AC8, JN034056) that did not exhibit flagella were Vahlkampfia species. Conclusion To date, pathogenic species of N. fowleri have not been isolated from Malaysia. All 39 isolates that produced amplicons (408, 450 and 457 bp) from the genus-specific primers were identified as being similar to nonpathogenic Naegleria. Amplicon 408 bp from 5 representative isolates showed 100% and 99.7% identity to Naegleria philippinensis isolate RJTM (AM167890) and is thus believed to be the most common species in our environment. Amplicons 450 bp and 457 bp were respectively believed to be from 2 new species of Naegleria, since representative isolates showed lower homology and had a longer base pair length when compared to the reference

  5. Characterization and survival of environmental Escherichia coli O26 isolates in ground beef and environmental samples.

    Science.gov (United States)

    Palmer, Christine E; Bratcher, Christy L; Singh, Manpreet; Wang, Luxin

    2015-04-01

    In addition to Escherichia coli O157:H7, shiga toxin-producing E. coli (STEC) O26 was added to the zero-tolerance adulterant list together with other 5 non-O157 STEC serogroups in 2012. Four farm O26 isolates were used in this study; they were obtained from a on-farm survey study conducted in Alabama. The presence of 3 major pathogenic genes (stx1, stx2, and eaeA) was determined through multiplex polymerase chain reaction (PCR). Two major pathogenic gene profiles were observed: 3 of the farm isolates contain only the eaeA gene whereas 1 farm isolate has both the eaeA and the stx1 genes. No significant difference was seen among the 4 farm isolates in the antibiotic resistance tests. To test their survival in ground beef and environmental samples, 2 inoculums were prepared and inoculated at various concentrations into samples of ground beef, bovine feces, bedding materials, and trough water. One inoculum was made of 3 farm isolates containing only the eaeA gene and another inoculum contained the isolate with both the eaeA and stx1 genes. Inoculated beef samples were stored at 4 °C for 10 d and the inoculated environmental samples were stored at ambient temperature for 30 d. Results showed that virulence gene profiles do not have an impact on O26's ability to survive in ground beef and in environment (P > 0.05). The inoculation levels, sample types as well as the storage times are the major factors that impact O26 survival (P < 0.05). © 2015 Institute of Food Technologists®

  6. Storage Effects on Sample Integrity of Environmental Surface Sampling Specimens with Bacillus anthracis Spores.

    Science.gov (United States)

    Perry, K Allison; O'Connell, Heather A; Rose, Laura J; Noble-Wang, Judith A; Arduino, Matthew J

    The effect of packaging, shipping temperatures and storage times on recovery of Bacillus anthracis . Sterne spores from swabs was investigated. Macrofoam swabs were pre-moistened, inoculated with Bacillus anthracis spores, and packaged in primary containment or secondary containment before storage at -15°C, 5°C, 21°C, or 35°C for 0-7 days. Swabs were processed according to validated Centers for Disease Control/Laboratory Response Network culture protocols, and the percent recovery relative to a reference sample (T 0 ) was determined for each variable. No differences were observed in recovery between swabs held at -15° and 5°C, (p ≥ 0.23). These two temperatures provided significantly better recovery than swabs held at 21°C or 35°C (all 7 days pooled, p ≤ 0.04). The percent recovery at 5°C was not significantly different if processed on days 1, 2 or 4, but was significantly lower on day 7 (day 2 vs. 7, 5°C, 10 2 , p=0.03). Secondary containment provided significantly better percent recovery than primary containment, regardless of storage time (5°C data, p ≤ 0.008). The integrity of environmental swab samples containing Bacillus anthracis spores shipped in secondary containment was maintained when stored at -15°C or 5°C and processed within 4 days to yield the optimum percent recovery of spores.

  7. New Lipids From Cultured Archaea and Environmental Samples

    Science.gov (United States)

    Summons, R. E.; Meyer-Dombard, D. R.; Bradley, A. S.; Hebting, Y.; Jahnke, L. L.; Embaye, T.; Orphan, V. J.

    2006-12-01

    The intact polar lipids of Archaea comprise cores with isoprenoid hydrocarbon chains with 20, 25 or 40 carbon atoms linked through ether bonds to glycerol. These cores can take the form of diethers or membrane- spanning tetraethers. Together with their wide array of polar head groups, these compounds are structurally diverse and potentially very useful as taxonomic markers for making assessments of microbial diversity independently of genomic approaches. Furthermore, the recalcitrant hydrocarbon chains of these lipids are the only really effective means to identify the presence of Archaea in ancient sedimentary environments. The advent of new LC-MS methods has enabled ready identification and quantification of intact polar lipids in cultures and environmental samples based on comparisons with appropriate standard compounds [1, 2]. However, these LC-MS analyses of intact lipids have also revealed the presence of additional compounds and it is likely that many of these represent chemical structures that are new to science. Elucidating these structures is a major analytical challenge because, generally, only minute amounts of material available for chemical characterization. In order to study these potentially new structures, one layer of information can be obtained by chemical degradation to remove and identify the polar head groups [2]. Cleavage of the ether bonds releases the hydrocarbon chains for their further characterization. One class of core lipids, the 3-hydroxyarchaeols, escaped detection for many years because strong acid treatments in the analysis protocols had destroyed hydroxyl-containing isoprenoid chains. We have now re-examined the lipids of a thermophilic methanogen, M. thermolithotrophicus, using mild procedures and avoiding strong acids. As well as the known compounds archaeol, sn-2-hydroxyarchaeol and sn-3-hydroxyarchaeol, we encountered dihydroxyarchaeol. Moreover, the hydroxylated archaeols were found to exist as a very complex mixture of

  8. Genomic Sequencing of Single Microbial Cells from Environmental Samples

    Energy Technology Data Exchange (ETDEWEB)

    Ishoey, Thomas; Woyke, Tanja; Stepanauskas, Ramunas; Novotny, Mark; Lasken, Roger S.

    2008-02-01

    Recently developed techniques allow genomic DNA sequencing from single microbial cells [Lasken RS: Single-cell genomic sequencing using multiple displacement amplification, Curr Opin Microbiol 2007, 10:510-516]. Here, we focus on research strategies for putting these methods into practice in the laboratory setting. An immediate consequence of single-cell sequencing is that it provides an alternative to culturing organisms as a prerequisite for genomic sequencing. The microgram amounts of DNA required as template are amplified from a single bacterium by a method called multiple displacement amplification (MDA) avoiding the need to grow cells. The ability to sequence DNA from individual cells will likely have an immense impact on microbiology considering the vast numbers of novel organisms, which have been inaccessible unless culture-independent methods could be used. However, special approaches have been necessary to work with amplified DNA. MDA may not recover the entire genome from the single copy present in most bacteria. Also, some sequence rearrangements can occur during the DNA amplification reaction. Over the past two years many research groups have begun to use MDA, and some practical approaches to single-cell sequencing have been developed. We review the consensus that is emerging on optimum methods, reliability of amplified template, and the proper interpretation of 'composite' genomes which result from the necessity of combining data from several single-cell MDA reactions in order to complete the assembly. Preferred laboratory methods are considered on the basis of experience at several large sequencing centers where >70% of genomes are now often recovered from single cells. Methods are reviewed for preparation of bacterial fractions from environmental samples, single-cell isolation, DNA amplification by MDA, and DNA sequencing.

  9. Development of analytical techniques for water and environmental samples (2)

    Energy Technology Data Exchange (ETDEWEB)

    Eum, Chul Hun; Jeon, Chi Wan; Jung, Kang Sup; Song, Kyung Sun; Kim, Sang Yeon [Korea Institute of Geology Mining and Materials, Taejon (Korea)

    1998-12-01

    The purpose of this study is to develop new analytical methods with good detection limit for toxic inorganic and organic compounds. The analyses of CN, organic acids, particulate materials in environmental samples have been done using several methods such as Ion Chromatography, SPE, SPME, GC/MS, GC/FID, SPLITT (split-flow thin cell fractionation) during the second year of this project. Advantage and disadvantage of several distillation method (by KS, JIS, EPA) for CN analysis in wastewater were investigated. As the results, we proposed new distillation apparatus for CN analysis, which was proved to be simpler, faster and to get better recovery than conventional apparatus. And ion chromatograph/pulsed amperometric detector (IC/PAD) system instead of colorimetry for CN detection was setup to solve matrix interference. And SPE(solid phase extraction) and SPME (solid phase micro extraction) as liquid-solid extraction technique were applied to the analysis of phenols in wastewater. Optimum experimental conditions and factors influencing analytical results were determined. From these results, It could be concluded that C{sub 18} cartridge and polystyrene-divinylbenzene disk in SPE method, polyacrylate fiber in SPME were proper solid phase adsorbent for phenol. Optimum conditions to analyze phenol derivatives simultaneously were established. Also, Continuous SPLITT (Split-flow thin cell) Fractionation (CSF) is a new preparative separation technique that is useful for fractionation of particulate and macromolecular materials. CSF is carried out in a thin ribbon-like channel equipped with two splitters at both inlet and outlet of the channel. In this work, we set up a new CSF system, and tested using polystyrene latex standard particles. And then we fractionated particles contained in air and underground water based on their sedimentation coefficients using CSF. (author). 27 refs., 13 tabs., 31 figs.

  10. Environmental remediation of heavy metal ions from aqueous solution through hydrogel adsorption: a critical review.

    Science.gov (United States)

    Muya, Francis Ntumba; Sunday, Christopher Edoze; Baker, Priscilla; Iwuoha, Emmanuel

    2016-01-01

    Heavy metal ions such as Cd(2+), Pb(2+), Cu(2+), Mg(2+), and Hg(2+) from industrial waste water constitute a major cause of pollution for ground water sources. These ions are toxic to man and aquatic life as well, and should be removed from wastewater before disposal. Various treatment technologies have been reported to remediate the potential toxic elements from aqueous media, such as adsorption, precipitation and coagulation. Most of these technologies are associated with some shortcomings, and challenges in terms of applicability, effectiveness and cost. However, adsorption techniques have the capability of effectively removing heavy metals at very low concentration (1-100 mg/L). Various adsorbents have been reported in the literature for this purpose, including, to a lesser extent, the use of hydrogel adsorbents for heavy metal removal in aqueous phase. Here, we provide an in-depth perspective on the design, application and efficiency of hydrogel systems as adsorbents.

  11. New Photochemical and Electrochemical Methods for the Degradation of Pesticides in Aqueous media. Environmental Applications

    OpenAIRE

    AARON, Jean Jacques

    2014-01-01

    The development of new electrochemical and photochemical methods for the decontamination of natural water containing significant concentrations of aromatic pesticides is described. The electrochemical method is based on the electro-Fenton process, i.e. the simultaneous reduction of O2 and Fe3+ ions. Hydroxyl (OH.) radicals are electrosynthesized in aqueous solutions, followed by complete mineralization of the initial pollutants. The photochemical methods involve either a direct pho...

  12. Fast methods for determination of antropogenic actinides and U/Th-series isotopes in aqueous samples.

    Science.gov (United States)

    Eikenberg, J; Bajo, S; Beer, H; Hitz, J; Ruethi, M; Zumsteg, I; Letessier, P

    2004-01-01

    Rapid and simple methods are applied at the PSI radioanalytical laboratory for determining anthropogenic actinides in waste and nuclear reactor waters (U, Pu, Am, Cm) as well as for analysis of naturally occurring alpha-emitters in continental river and ground water. Anion exchange chromatography followed by alpha-spectrometry as well as alpha/beta-LSC is applied for the reactor coolant waters. To avoid alpha-spectrum interference between 238Pu and 241Am at 5.5 MeV, the Pu-fraction is purified using anion exchange resin. Prior to the separation of the Pu-fraction, all actinides (U, Pu, Am, Cm) are adsorbed batch-wise under stirring onto Actinide Resin and subsequent decomposition of the reagent. The residue is then re-dissolved in a sulfate buffer solution for electrolytic deposition. In tabular water samples isotopes of Ra and Po are analyzed additionally via sorption onto manganese coated discs (Ra) and deposition on silver discs (Po). For counting times of 1 day and use of 0.1-1l sample aliquots, detection limits of a few mBql(-1) can be obtained easily.

  13. Storage Effects on Sample Integrity of Environmental Surface Sampling Specimens with Bacillus anthracis Spores

    Science.gov (United States)

    Perry, K. Allison; O’Connell, Heather A.; Rose, Laura J.; Noble-Wang, Judith A.; Arduino, Matthew J.

    2016-01-01

    The effect of packaging, shipping temperatures and storage times on recovery of Bacillus anthracis. Sterne spores from swabs was investigated. Macrofoam swabs were pre-moistened, inoculated with Bacillus anthracis spores, and packaged in primary containment or secondary containment before storage at −15°C, 5°C, 21°C, or 35°C for 0–7 days. Swabs were processed according to validated Centers for Disease Control/Laboratory Response Network culture protocols, and the percent recovery relative to a reference sample (T0) was determined for each variable. No differences were observed in recovery between swabs held at −15° and 5°C, (p ≥ 0.23). These two temperatures provided significantly better recovery than swabs held at 21°C or 35°C (all 7 days pooled, p ≤ 0.04). The percent recovery at 5°C was not significantly different if processed on days 1, 2 or 4, but was significantly lower on day 7 (day 2 vs. 7, 5°C, 102, p=0.03). Secondary containment provided significantly better percent recovery than primary containment, regardless of storage time (5°C data, p ≤ 0.008). The integrity of environmental swab samples containing Bacillus anthracis spores shipped in secondary containment was maintained when stored at −15°C or 5°C and processed within 4 days to yield the optimum percent recovery of spores. PMID:27213119

  14. k0-PGNAA of pollutants in aqueous samples using MCNP code

    Directory of Open Access Journals (Sweden)

    A. Hamid

    2014-03-01

    Full Text Available Prompt γ-neutron activation analysis (PGNAA using the k0 method by employing the 1951.1 keV γ-line of the 35Cl(n, γ36Cl thermal neutron reaction as monostandard comparator was described. The method has been applied and evaluated using the anti-Compton prompt γ-ray neutron activation analysis facility using 252Cf neutron source with a neutron flux of 6.16 · 106 n · cm-2 · s-1. A well-type HPGe detector as the main detector surrounded by NaI(Tl guard detector has been arranged to investigate the performance of the Compton suppression spectrometer using the simplified slow circuit. The properties of neutron flux were determined by MCNP code calculations. In order to determine the efficiency curve of an HPGe detector, the prompt γ-rays from chlorine were used and an exponential curve was fitted. AC-PGNAA method has been used for the determination of high neutron absorbing elements like Cd, Sm and Gd as well as 20 light and heavy elements (Na, Mg, Al, Si, P, K, Ca, Ti, V, Mn, Sc, Fe, Co, Zn, La, Rb, Cs, As and Th in standard reference materials (IAEA, Soil-7 and ten sediment samples collected from El-Manzala lake in northern part of Egypt. The reference material IAEA, Soil-7 was analyzed for data validation and good agreement between the experimental values and the certified values have been obtained.

  15. In-tube extraction for enrichment of volatile organic hydrocarbons from aqueous samples.

    Science.gov (United States)

    Jochmann, Maik A; Yuan, Xue; Schilling, Beat; Schmidt, Torsten C

    2008-02-01

    In-tube extraction (ITEX) is a novel solventless extraction technique in which a headspace syringe with a needle body filled with a sorbent (here: Tenax TA) is used. The analytes are extracted from sample headspace by dynamic extraction. The needle body is surrounded by a separate heater, which is used for thermal desorption of analytes into the injection port of a GC system. We report here for the first time the optimization and evaluation of a fully automated analytical method based on ITEX. As target analytes, 19 common groundwater contaminants such as halogenated volatiles and monoaromatic compounds have been chosen. Method related parameters such as extraction temperature, number of extraction cycles, extraction and desorption volume as well as extraction and desorption flow rates were investigated in detail. The linear dynamic range of the ITEX method ranged over six orders of magnitude between 0.028 microg/L and 1218 microg/L with linear correlation coefficients between 0.990 and 0.998 for the investigated compounds. Method detection limits for monoaromatic compounds were between 28 ng/L (ethylbenzene) and 68 ng/L (1,2,4-trimethylbenzene). For halogenated volatile organic compounds, method detection limits between 48 ng/L (chloroform) and 799 ng/L (dichloromethane) were obtained. The precision of the method with external calibration was between 3.1% (chloroform ethylbenzene) and 7.4% (1,2,3-trimethylbenzene).

  16. Determination of rhenium in environmental samples by ICP-MS

    International Nuclear Information System (INIS)

    Tagami, Keiko; Uchida, Shigeo

    2002-01-01

    A simple separation method for Re determination in rock and seawater samples by inductively coupled plasma mass spectrometry (ICP-MS) has been developed. An extraction chromatographic resin (TEVA resin, Eichrom Ind. Inc.) was employed to separate Re from sample matrices and trace elements that cause isobaric interference during ICP-MS measurements. Total average yields were 94±3% for rock and soil samples and almost 100% for water samples. The method was applied to trace-level Re determination in standard igneous rock and seawater samples. The measured Re values were 0.05 - 4.0 ng/g for the rock samples and 6.3 - 12.7 pg/mL for the seawater samples. (author)

  17. Hemimicelle capped functionalized carbon nanotubes-based nanosized solid-phase extraction of arsenic from environmental water samples

    International Nuclear Information System (INIS)

    Li Lu; Huang Yuming; Wang Yan; Wang Weidong

    2009-01-01

    The end functionalization of CNTs can introduce oxygen-containing negatively functional groups such as -COOH, -OH, or -C=O on their surface site. If cationic surfactant such as cetyltrimethylammonium chloride (CTAC) was added to the functionalized CNTs, then interactions such as hydrophobic and ionic may lead to formation of hemimicelle/admicelle aggregates on the CNTs, a new kind of adsorbents, namely, the hemimicelle capped CMMWCNTs, is obtained. The application of the hemimicelle capped carbon nanotubes-based nanosized solid-phase extraction (SPE) adsorbents in environmental analysis is reported for the first time using arsenic as model target. The effect of adsorption and desorption conditions for arsenic including the amount of surfactant, initial pH of sample solution, the ultrasonic time of sample solution, the amount of electrolyte, flow rate, eluent and its amount were investigated and optimized prior to its determination by atomic fluorescence spectrophotometry (AFS). Arsenic can be quantitatively retained on the hemimicelle capped CMMWCNTs at pH 5-6 from sample volume up to 500 mL and then eluted completely with 2 mol L -1 HNO 3 in the presence of 10 mg L -1 CTAC. The method detection limit for arsenic determination with AFS detection was 2 ng L -1 , and the relative standard deviation (RSD, n = 11) was 5.3% at the 0.5 μg L -1 level. The recoveries of arsenic in the spiked environmental water samples ranged from 94% to 104.29% with 500 mL of water sample. The proposed method has been applied successfully to the analysis of arsenic in aqueous environmental samples, which demonstrates the hemimicelle capped CMMWCNTs can be an excellent SPE adsorbents for arsenic pretreatment and enrichment from real water samples

  18. Zn(II)-concentration dependent Raman spectra in the dithizone complex on gold nanoparticle surfaces in environmental water samples

    Science.gov (United States)

    Ly, Nguyen Hoang; Joo, Sang-Woo

    2015-11-01

    After the formation of dithizone with metal ion complexes, a selective Raman detection method for the Zn2+ ions in aqueous solutions was developed by observing the intensity change of the ring mode peaks at ∼1585 cm-1 on gold nanoparticles (AuNPs). At high concentrations of Zn2+ ions, the conformation of the dithizone complex may have different orientations on AuNPs to yield the spectral changes at ca. ∼510 and ∼1585 cm-1. The concentration dependent spectra changes indicated that a detection limit would be in the submicromolar region of Zn2+ ions. The other ions of Mg2+, K+, Fe3+, Hg2+, Co2+, Fe2+, Pb2+, Cu2+, Ni2+, Cr3+, NH4+, Cd2+, Na+, Ca2+, and Mn2+ at micromolar concentrations of 1 μM did not produce such spectral changes. The detection limit based on the Raman band intensities was estimated to be as low as 500 nM of Zn2+ ion in aqueous solutions. The three real samples of tap, river, and seawater were tested under the interference of the commonly existing interfering ions. Despite the presence of highly concentrated Na, Ca, Mg, and K, our interfacial spectroscopic methodology of Zn2+ determination could be applied in the environmental water samples.

  19. A simple, reversible, colorimetric and water-soluble fluorescent chemosensor for the naked-eye detection of Cu2 + in 100% aqueous media and application to real samples

    Science.gov (United States)

    Sun, Tao; Niu, Qingfen; Li, Tianduo; Guo, Zongrang; Liu, Haixia

    2018-01-01

    A simple, reversible, colorimetric and water-soluble fluorescent chemosensor ADA for the naked-eye detection of Cu2 + was developed. Sensor ADA showed high selectivity and sensitivity toward Cu2 + in 100% aqueous media over wide pH range. Sensor ADA exhibited a red-shift in the absorption spectra from 466 to 480 nm that is accompanied by significant color change from light yellow to yellowish brown instantaneously. The Cu2 + recognition is based on the chelation-enhanced fluorescence quenching (CHEQ) effect of the paramagnetic nature. The lowest detection limit is determined to be 15.8 nM, which is much lower than the allowable level of Cu2 + in drinking water set by U.S. Environmental Protection Agency ( 20 μM) and the World Health Organization ( 30 μM). The 1:1 binding process was confirmed by fluorescence measurements, IR analysis and DFT studies. Moreover, sensor ADA was successfully applied for determination of trace level of Cu2 + with 4 reuse cycles in various water samples, which affords promising potential in ion-detection field.

  20. BAYESIAN ENTROPY FOR SPATIAL SAMPLING DESIGN OF ENVIRONMENTAL DATA

    Science.gov (United States)

    Particulate Matter (PM) has been linked to widespread public health effects, including a range of serious respiratory and cardiovascular problems, and to reduced visibility in may parts of the United States, see the Environmental Protection Agency (EPA) report (2004) and relevant...

  1. Selective Micellar Extraction of Ultratrace Levels of Uranium in Aqueous Samples by Task Specific Ionic Liquid Followed by Its Detection Employing Total Reflection X-ray Fluorescence Spectrometry.

    Science.gov (United States)

    Saha, Abhijit; Sanyal, Kaushik; Rawat, Neetika; Deb, Sadhan Bijoy; Saxena, Manoj Kumar; Tomar, Bhupendra Singh

    2017-10-03

    A task specific ionic liquid (TSIL) bearing phosphoramidate group, viz., N-propyl(diphenylphosphoramidate)trimethylammonium bis(trifluoromethanesulfonyl)imide, was synthesized and characterized by 1 H NMR, 13 C NMR, 31 P NMR, and IR spectroscopies, elemental (C H N S) analysis, and electrospray ionization mass spectrometry (ESI-MS). Using this TSIL a cloud point extraction (CPE) or micelle mediated extraction procedure was developed for preconcentration of uranium (U) in environmental aqueous samples. Total reflection X-ray fluorescence spectrometry was utilized to determine the concentration of U in the preconcentrated samples. In order to understand the mechanism of the CPE procedure, complexation study of the TSIL with U was carried out by isothermal calorimetric titration, liquid-liquid extraction, 31 P NMR and IR spectroscopies, and ESI-MS. The developed analytical technique resulted in quantitative extraction efficiency of 99.0 ± 0.5% and a preconcentration factor of 99 for U. The linear dynamic range and method detection limit of the procedure were found to be 0.1-1000 ng mL -1 and 0.02 ng mL -1 , respectively. The CPE procedure was found to tolerate a higher concentration of commonly available interfering cations and anions, especially the lanthanides. The developed analytical method was validated by determining the concentration of U in a certified reference material, viz., NIST SRM 1640a natural water, which was found to be in good agreement at a 95% confidence limit with the certified value. The method was successfully applied to the U determination in three natural water samples with ≤4% relative standard deviation (1σ).

  2. Determination of uranium in industrial and environmental samples. Vol. 4

    International Nuclear Information System (INIS)

    El-Sweify, F.H.; Shehata, M.K.; Metwally, E.M.; El-Shazly, E.A.A.; El-Naggar, H.A.

    1996-01-01

    The phosphate ores used at 'Abu zaabal fertilizer and chemical company' for the production of some chemicals and fertilizers contain detectable amounts of uranium. In this study, the content of uranium in samples of different products of fertilizers, gypsum, and phosphate ore were determined using NAA, and gamma ray spectroscopy of the irradiated samples. Another method based on measuring the natural radioactivity of 238 U series for non-irradiated samples using gamma-ray spectroscopy was also used for determine uranium content in the samples. In the NAA method, the content of U(ppm) in the samples was been computed from the photopeak activity of the lines = 106.1, 228.2, and 277.5 KeV of 239 Np induced in the irradiated samples, and the uranium standard simultaneously irradiated. the gamma-ray spectra, and the decay curves are given. In the second method the gamma-ray spectra of the natural radioactivity of the samples and uranium standard were measured. The gamma-transition of energies 295.1, 251.9 KeV for 214 Pb; 609.3, 768.4, 1120.3, 1238.1 KeV for 214 Bi were determined. The uranium 23U traces in drainage water was also determined spectrophotometrically using arsenazo-III after preconcentration of uranium from the pretreated drainage water in column packed with chelex-100 resin. The recovery was found to be 90 ± 5%. 11 figs., 3 tabs

  3. DNA extraction for streamlined metagenomics of diverse environmental samples.

    Science.gov (United States)

    Marotz, Clarisse; Amir, Amnon; Humphrey, Greg; Gaffney, James; Gogul, Grant; Knight, Rob

    2017-06-01

    A major bottleneck for metagenomic sequencing is rapid and efficient DNA extraction. Here, we compare the extraction efficiencies of three magnetic bead-based platforms (KingFisher, epMotion, and Tecan) to a standardized column-based extraction platform across a variety of sample types, including feces, oral, skin, soil, and water. Replicate sample plates were extracted and prepared for 16S rRNA gene amplicon sequencing in parallel to assess extraction bias and DNA quality. The data demonstrate that any effect of extraction method on sequencing results was small compared with the variability across samples; however, the KingFisher platform produced the largest number of high-quality reads in the shortest amount of time. Based on these results, we have identified an extraction pipeline that dramatically reduces sample processing time without sacrificing bacterial taxonomic or abundance information.

  4. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2011

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2011-01-21

    This document contains the calendar year 2011 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and the Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis. If a sample will not be collected in 2011, the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2011.

  5. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2006

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2006-01-27

    This document contains the calendar year 2006 schedules for the routine and non-routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. Each section includes sampling locations, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis and may not be collected in 2006 in which case the anticipated year for collection is provided. The project document package (PDP) for Surface Environmental Surveillance contains the milestone control log for the issuing of CY06 Environmental Surveillance Master Sampling Schedule WBS 4.2.3.21.3.03, milestone: RL00430306 (4830106-12).

  6. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2006

    International Nuclear Information System (INIS)

    Bisping, Lynn E.

    2006-01-01

    This document contains the calendar year 2006 schedules for the routine and non-routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project. Each section includes sampling locations, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis and may not be collected in 2006 in which case the anticipated year for collection is provided. The project document package (PDP) for Surface Environmental Surveillance contains the milestone control log for the issuing of CY06 Environmental Surveillance Master Sampling Schedule WBS 4.2.3.21.3.03, milestone: RL00430306 (4830106-12)

  7. The application of x-ray fluorescence and diffraction to the characterization of environmental assessment samples

    International Nuclear Information System (INIS)

    Censullo, A.C.; Briden, F.E.

    1982-01-01

    Some of the results of tests on environmental assessment samples are reported on. The utility of the J.W. Criss fundamental parameters computer program is evaluated for samples in which only one standard per element was used and where the standard matrix did not strictly resemble the unknown matrix. The environmental significance of a sample is dependent not only on its elemental composition, but also on the species or phases which the elements comprise. X-ray powder diffraction may be used to advantage for speciation. Multi-phase environmental assessment samples are amenable to XRD interpretation. Some results of the application of the Joint Committee on Power Diffraction Standards computer interpretatin of typical environmental samples are discussed. They were shown to contribute to the specification of the complex samples that are encountered in environmental assessments

  8. Magnetic hydroxyapatite nanoparticles: an efficient adsorbent for the separation and removal of nitrate and nitrite ions from environmental samples.

    Science.gov (United States)

    Ghasemi, Ensieh; Sillanpää, Mika

    2015-01-01

    A novel type of magnetic nanosorbent, hydroxyapatite-coated Fe2O3 nanoparticles was synthesized and used for the adsorption and removal of nitrite and nitrate ions from environmental samples. The properties of synthesized magnetic nanoparticles were characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, and X-ray powder diffraction. After the adsorption process, the separation of γ-Fe2O3@hydroxyapatite nanoparticles from the aqueous solution was simply achieved by applying an external magnetic field. The effects of different variables on the adsorption efficiency were studied simultaneously using an experimental design. The variables of interest were amount of magnetic hydroxyapatite nanoparticles, sample volume, pH, stirring rate, adsorption time, and temperature. The experimental parameters were optimized using a Box-Behnken design and response surface methodology after a Plackett-Burman screening design. Under the optimum conditions, the adsorption efficiencies of magnetic hydroxyapatite nanoparticles adsorbents toward NO3(-) and NO2(-) ions (100 mg/L) were in the range of 93-101%. The results revealed that the magnetic hydroxyapatite nanoparticles adsorbent could be used as a simple, efficient, and cost-effective material for the removal of nitrate and nitrite ions from environmental water and soil samples. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  9. Investigation of environmental samples by low-level gamma spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Koehler, M. [Nuclear Engineering and Analytics Rossendorf, Inc., Dresden (Germany); Niese, S. [Nuclear Engineering and Analytics Rossendorf, Inc., Dresden (Germany)

    1997-03-01

    The average sample number in our laboratory is about 200 per month (12% technical solid state, 30% geological solid state, 6% geological solid state with low mass, 12% biological, 11% water directly, 25% water after chemical separation, 4% others). In 54% of the measurements the background continuum, and though the detection limit, is determined only by the detector himself and not by the compton continuum from high energy lines in the sample. Some examples in the presented work aim to prove the advantages of gamma ray spectrometry in the underground laboratory Felsenkeller. (orig./DG)

  10. Determination of chemical form of iodine with IC-ICP-MS system and its application to the environmental samples

    International Nuclear Information System (INIS)

    Yoshida, S.; Katou, S.; Sekimoto, H.; Muramatsu, Y.

    2005-01-01

    Iodine-129 is one of the important radionuclides possibly released into the environment from nuclear weapons testing and from the nuclear facilities such as nuclear fuel reprocessing plants. Because of its long half-life (1.57 x 10 7 y), knowing its long-term behavior in the environment is a major concern. As I-129 is expected to act together with stable iodine (I-127) in the environment after long time, the biogeochemical cycling of stable iodine in the environment can be used for the reliable safety assessment of I-129. Chemical form is the one of the important factors controlling the 'iodine behavior in the environment. Iodide (I - ) and iodate (IO 3 - ) are known to be the major chemical form in the aqueous solution. However, the information on the chemical form of iodine in the environmental sample is limited because of lack of reliable analytical technique for trace level of iodine in the environment. In this study, the analytical system by using ion chromatograph (IC) followed by inductively coupled plasma mass spectrometry (ICP-MS) was developed for the separate determination of I - and IO 3 - in the aqueous solution. The IC with anion exchange column (EXCELPAK ICS-A23) was used for the separation of I - and IO 3 - with 30 mM (NH 4 ) 2 CO 3 as eluent. Separated iodine was determined with ICP-MS on line. with the detection limit 0.1 - 1 μg/L. The total iodine concentration was also measured by the direct determination with ICP-MS. The iodine in the several environmental samples such as irrigation water in paddy field was successfully determined with information of chemical form. In incubation experiment with flooded soil, the change of the chemical form of iodine in the soil solution with change of Eh was observed. Detailed data will be discussed in the presentation.

  11. Measurement of Difficult-to-Measure Radionuclides in Environmental Samples

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Mun Ja; Choi, G S; Cho, Y. H.; Jeong, K. H.; Kim, H. R.; Park, D. W.

    2010-07-15

    Analytical procedures for technetium-99 and iodine-129 radioactivity in groundwater and seaweed sampled around radioactive waste disposal site were established. Quality control procedure for the radiochemical analysis was also prepared. Radiochemical analysis for technetium-99 in 72 groundwaters sampled around disposal site from 2007 to 2009 was performed. Radioactivities of technetium-99 were below MDA. The MDAs were obtained from <0.0643 to <0.0837 Bq/L. Radiochemical analysis for iodine-129 in 72 groundwaters was also carried out. Radioactivities of iodine-129 were below MDA. The MDAs were obtained from <0.0175 to <0.0470 Bq/L. Radioactivity of iodine-129 in 12 seaweeds sampled around disposal site was measured. Radioactivity of iodine-129 in the seaweeds were below MDA. The MDAs reached from <0.153 to <1.31 Bq/kg-fresh. For the verification of the analytical procedure, our lab. participated inter-comparison performance test organized by NPL. From the result of data evaluation by NPL, our lab obtained 'In Agreement' in the analysis of technetium-99 and iodine-129 of water sample

  12. Rapid methods for strontium determination in environmental samples

    International Nuclear Information System (INIS)

    Buchtela, Karl

    1995-01-01

    The simultaneous determination of strontium-90 and strontium-89 is usually done by separation of yttrium-90 after a suitable time for the growth of yttrium-90. Investigations are of interest to try a yttrium-90 measurement without separation by observing the increase of activity of the strontium sample due to the production and decay of the daughter nuclide yttrium-90. Also it can be tried to use liquid scintillation spectroscopy to discriminate strontium-89 (1.46 MeV) from strontium-90 (0.55 MeV) immediately after the strontium precipitation. Until now all these determinations are only possible if the strontium-90 activity is not too low compared with the the strontium-89 content of the sample. Unfortunately regarding this possibility of determination but fortunately from the point of view of radiation protection immediately after a nuclear accident in most cases the activity of strontium-90 is much lower than that of strontium-89. Liquid scintillation spectroscopy does not give reliable results for low strontium-90 activity if a high strontium-89 activity is observed in a sample. The growth of yttrium-90 in a sample of strontium-89/90 will increase the total activity. After a suitable period of time this increase might be sufficiently high to provide reliable information about the strontium-90 content. Due to statistics no reliable information will be provided for samples with an excess of strontium-89. If the strontium-89 activity is 20 times higher than the strontium-90 activity, no reliable information can be obtained, if it is 5 times higher, it is possible to provide a quantitative information about the growth of yttrium-90 after 36 hours, and if twice the activity of strontium-89 compared to the strontium-90 were observed, there would be no difficulties for the simultaneous determination of both radionuclides. Dealing with the situation of high strontium-89 contribution an yttrium separation probably is unavoidable

  13. Dry Deposition of Biogenic Terpenes via Cationic Oligomerization on Environmental Aqueous Surfaces.

    Science.gov (United States)

    Enami, Shinichi; Hoffmann, Michael R; Colussi, Agustín J

    2012-11-01

    Unraveling the complex interactions between the atmosphere and the biosphere is critical for predicting climate changes. Although it is well-recognized that the large amounts of biogenic volatile organic compounds (BVOCs) emitted by plants must play important roles in this regard, current atmospheric models fail to account for their fate due to missing chemical sinks. Here, we applied online electrospray mass spectrometry to monitor aqueous microjets exposed to gaseous monoterpenes (α-pinene, β-pinene, and d-limonene) and found that these BVOCs are readily protonated (to C10H17(+)) and undergo oligomerization (to C20H33(+) and C30H49(+)) upon colliding with the surface of pH < 4 microjets. By considering that the yields of all products show inflection points at pH ≈ 3.5 and display solvent kinetic hydrogen isotope effects larger than 2, we conclude that the oligomerization process is initiated by weakly hydrated hydronium ions, H3O(+), present at the gas-water interface. Present results provide a universal mechanism for the dry deposition of unsaturated BVOCs and may account for recent observations on the uptake of terpenes in forest canopies and over grassland.

  14. The sampling and analysing methods of radionuclides used in the Nordic countries for environmental samples

    International Nuclear Information System (INIS)

    Taipale, Tarja K.

    1985-01-01

    The Radioecology Group under the Nordic Liaison Committee for Atomic Energy has considered it to be of great importance to improve the comparability of environmental radioactivity measurements in the Nordic countries, a basic requirement for co-ordinated research programmes. In case of emergency, good comparability between the results obtained will be required for mutual assistance. Therefore several intercomparison exercises have been carried out between the laboratories measuring environmental radioactivity. The exercises have proved very useful and have led to a more comprehensive and systematic survey of the environmental measurement methodology used so far by the Nordic laboratories. Furthermore it is considered necessary to make some recommendations or even to reach an agreement on how to present the results in order to make the comparison of, at least, monitoring data easier. This report is based on the answers received from the participating laboratories to a questionnaire sent by the Finnish Centre for Radiation and Nuclear Safety, Helsinki

  15. Gas chromatography/isotope ratio mass spectrometry: analysis of methanol, ethanol and acetic acid by direct injection of aqueous alcoholic and acetic acid samples.

    Science.gov (United States)

    Ai, Guomin; Sun, Tong; Dong, Xiuzhu

    2014-08-15

    Methanol, ethanol, and acetic acid are not easily extracted from aqueous samples and are susceptible to isotope fractionation in gas chromatography/isotope ratio mass spectrometry (GC/IRMS) analysis. Developing a direct dilution GC/IRMS method for aqueous samples, by adjusting the sample concentrations in common solvents to be similar to each other and using a fixed GC split ratio, is very convenient and important because any linearity effects caused by amount-dependent isotope fractionation can be avoided. The suitability of acetonitrile and acetone solvents for the GC/IRMS analysis of pure methanol, ethanol and acetic acid, and commercial liquor and vinegar samples was evaluated using n-hexane and water as control solvents. All the solvents including water were separated from the analyte on a HP-INNOWAX column and were diverted away from the combustion interface. The influence of liquor matrix on the ethanol GC/IRMS analyses was evaluated by adding pure ethanol to liquor samples. Acetonitrile and acetone gave similar δ(13) C values for pure ethanol and pure acetic acid to those obtained in water and n-hexane, and also gave similar δ(13) C values of ethanol in liquor and acetic acid in white vinegar to that obtained in water. For methanol analysis, acetonitrile and refined acetone gave similar δ(13) C values to that obtained in water, but n-hexane was not a suitable solvent. In addition, isotopic fractionation caused by solvent and solute interactions was observed. We recommend using acetonitrile for the GC/IRMS analysis of aqueous alcoholic samples, and acetone for the analysis of aqueous acetic acid samples. This direct dilution method can provide high accurate and precise GC/IRMS analysis of the relative changes in δ(13) C values of methanol, ethanol, and acetic acid. Copyright © 2014 John Wiley & Sons, Ltd.

  16. Application of acetone acetals as water scavengers and derivatization agents prior to the gas chromatographic analysis of polar residual solvents in aqueous samples.

    Science.gov (United States)

    van Boxtel, Niels; Wolfs, Kris; Van Schepdael, Ann; Adams, Erwin

    2015-12-18

    The sensitivity of gas chromatography (GC) combined with the full evaporation technique (FET) for the analysis of aqueous samples is limited due to the maximum tolerable sample volume in a headspace vial. Using an acetone acetal as water scavenger prior to FET-GC analysis proved to be a useful and versatile tool for the analysis of high boiling analytes in aqueous samples. 2,2-Dimethoxypropane (DMP) was used in this case resulting in methanol and acetone as reaction products with water. These solvents are relatively volatile and were easily removed by evaporation enabling sample enrichment leading to 10-fold improvement in sensitivity compared to the standard 10μL FET sample volumes for a selection of typical high boiling polar residual solvents in water. This could be improved even further if more sample is used. The method was applied for the determination of residual NMP in an aqueous solution of a cefotaxime analogue and proved to be considerably better than conventional static headspace (sHS) and the standard FET approach. The methodology was also applied to determine trace amounts of ethylene glycol (EG) in aqueous samples like contact lens fluids, where scavenging of the water would avoid laborious extraction prior to derivatization. During this experiment it was revealed that DMP reacts quantitatively with EG to form 2,2-dimethyl-1,3-dioxolane (2,2-DD) under the proposed reaction conditions. The relatively high volatility (bp 93°C) of 2,2-DD makes it possible to perform analysis of EG using the sHS methodology making additional derivatization reactions superfluous. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Guidance for establishment and implementation of a national sample management program in support of EM environmental sampling and analysis activities

    International Nuclear Information System (INIS)

    1994-01-01

    The role of the National Sample Management Program (NSMP) proposed by the Department of Energy's Office of Environmental Management (EM) is to be a resource for EM programs and for local Field Sample Management Programs (FSMPs). It will be a source of information on sample analysis and data collection within the DOE complex. Therefore the NSMP's primary role is to coordinate and function as a central repository for information collected from the FSMPs. An additional role of the NSMP is to monitor trends in data collected from the FSMPs over time and across sites and laboratories. Tracking these trends will allow identification of potential problems in the sampling and analysis process

  18. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2007

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2007-01-31

    This document contains the calendar year 2007 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis and may not be collected in 2007 in which case the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2007.

  19. Aqueous chemistry of chlorine: chemistry, analysis, and environmental fate of reactive oxidant species

    Energy Technology Data Exchange (ETDEWEB)

    Jolley, R.L.; Carpenter, J.H.

    1982-01-01

    This report reviews (1) the chemistry of chlorine relative to its reactions in fresh, estuarine, and marine waters and the formation of reactive oxidant species; (2) the current status of chemical analysis of reactive chlorine species and chlorine-produced oxidant species relative to analysis of low concentrations (microgram-per-liter range) and determination of accuracy and precision of methods; and (3) the environmental fate of chlorine and chlorine-produced oxidant species.

  20. Development of a laser ionization mass spectrometer for the rapid detection of aromatic hydrocarbons in aqueous samples

    Energy Technology Data Exchange (ETDEWEB)

    Oser, H.; Young, S.E.; Coggiola, J. [SRI International, Menlo Park, CA (United States). Molecular Physics Lab.; Hafer, V. [Wellesley Coll., MA (United States); Grist, G. [San Francisco State Univ., CA (United States)

    2004-09-15

    The detection of BTEX compounds in the gas phase has been examined in our laboratory through the use of jet-Resonantly Enhanced Multi-Photon Ionization Time-of-Flight Mass Spectrometry (jet-REMPI-ToF MS). These BTEX compounds, as well as chlorobenzene, are well suited for detection via this method due to spectroscopic absorption properties of the aromatic ring. However, this method utilizes a supersonic jet expansion, which is not applicable to the direct detection of BTEX compounds in water. In order to extend the REMPI-ToF approach to the detection of organics in water, a new type of inlet system must be coupled to the REMPI apparatus. By combining a membrane-based inlet system with a REMPI apparatus, the volatile organic compounds (VOCs) can be successfully introduced into the vacuum chamber without interference from the water solvent. Membrane Introduction Mass Spectrometry (MIMS) has been utilized for over 40 years, but the coupling of a membrane inlet to REMPI ToF mass spectrometry is new. A combination of MIMS and REMPI with time-of flight mass spectrometry, which allows for the direct analysis of water samples, has been developed in our laboratory. The application of ToF MS offers some advantages such as high ion transmission, robustness, and the ability to record a full mass spectrum for each laser shot. The objective of this research was the detection of trace amounts of aromatic contaminants, particularly BETX and chlorobenzene, in aqueous solutions without interference or clogging of the inlet due to the vastly greater amount of water.

  1. Investigations into the environmental conditions experienced during ambient sample transport: impact to dried blood spot sample shipments.

    Science.gov (United States)

    Bowen, Chester L; Dopson, Wesley; Kemp, Daniel C; Lewis, Mark; Lad, Rakesh; Overvold, Carol

    2011-07-01

    Prior to bioanalysis, sample transport and storage are critical considerations in any pharmacokinetic or toxicokinetic study design. Care must be taken to ensure the shipment is properly packaged and tracked to make certain it arrives at the desired, final destination in the appropriate timeframe, and that the integrity of the sample is not compromised. When dealing with biological specimens, environmental conditions may have a deleterious effect on the stability and conditions of the sample. Currently, frozen plasma or blood samples are the matrix of choice within the pharmaceutical industry for analysis within both preclinical and clinical trials. Liquid samples are shipped and received frozen and, therefore, the assumption is made that the frozen conditions are maintained throughout the entire transit process. Dried blood spot and dried matrix spot samples are becoming popular alternatives to plasma sampling in many small- and even large-molecule applications. With the implementation of dried blood spot and dried matrix spot samples, shipping and storage occurs under ambient conditions. In this article we discuss various shipping containers for these samples, illustrate the environmental extremes encountered during the shipping process, demonstrate a cost-effective method of monitoring both temperature and humidity, and discuss validation steps that may be implemented to minimize the impact of these variables on your study design.

  2. Development of counter current salting-out homogenous liquid-liquid extraction for isolation and preconcentration of some pesticides from aqueous samples.

    Science.gov (United States)

    Farajzadeh, Mir Ali; Feriduni, Behruz; Afshar Mogaddam, Mohammad Reza

    2015-07-23

    In this paper, a new version of salting-out homogenous liquid-liquid extraction based on counter current mode combined with dispersive liquid-liquid microextraction has been developed for the extraction and preconcentration of some pesticides from aqueous samples and their determination by gas chromatography-flame ionization detection. In order to perform the method, aqueous solution of the analytes containing acetonitrile and 1,2-dibromoethane is transferred into a narrow bore tube which is filled partially with NaCl. During passing the solution through the tube, fine droplets of the organic phase are produced at the interface of solution and salt which go up through the tube and form a separated layer on the aqueous phase. The collected organic phase is removed and injected into de-ionized water for more enrichment of the analytes. Under the optimum extraction conditions, the method shows broad linear ranges for the target analytes. Enrichment factors and limits of detection for the selected pesticides are obtained in the ranges of 3480-3800 and 0.1-5μgL(-1), respectively. Relative standard deviations are in the range of 2-7% (n=6, C=50 or 100μgL(-1), each analyte). Finally, some aqueous samples were successfully analyzed using the developed method. Copyright © 2015 Elsevier B.V. All rights reserved.

  3. A note on {sup 207}Bi in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Bossew, P. [European Commission, DG Joint Research Centre, Institute of Environment and Sustainability, Radioactivity Environmental Monitoring Group. Via Fermi 1, I-21020 Ispra, Vatican City State, Holy See (Italy)]. E-mail: peter.bossew@jrc.it; Lettner, H. [Institute of Physics and Biophysics, University of Salzburg, Hellbrunner Strasse 34, A-5020 Salzburg (Austria)]. E-mail: herbert.lettner@sbg.ac.at; Hubmer, A. [Institute of Physics and Biophysics, University of Salzburg, Hellbrunner Strasse 34, A-5020 Salzburg (Austria)

    2006-07-01

    Traces of the radionuclide {sup 207}Bi were identified in soil and cryoconite (glacier sediment) samples from Alpine regions of Austria. This nuclide has been produced in thermonuclear explosions mainly in the early 1960s and subsequently dispersed in the atmosphere. Activity concentrations up to 22 Bq/kg d.m. have been found. The ratio {sup 207}Bi:{sup 137}Cs(global fallout) equals (1.70 {+-} 0.12)10{sup -3}, which is in accordance with literature data. When low levels of {sup 207}Bi are assessed by gamma spectrometry, corrections must be made for a gamma line produced in the lead shield by neutron activation due to cosmic neutrons.

  4. PIXE analysis of marine environmental samples from the Pacific Ocean

    International Nuclear Information System (INIS)

    Miyake, Hiroshi; Matsuda, Yasuhiro; Shitashima, Kiminori; Tsubota, Hiroyuki.

    1990-01-01

    Aerosol samples from the western North Pacific Ocean are collected during a cruise of R/V Hakuhomaru from Japan to Hawaii and they are analyzed by PIXE (particle induced X-ray emission). Concentrations of radon daughters are measured with CR-39 track detectors mounted on the impactor to estimate the transport time of air mass from the Asian Continent. Distributions of particulate element concentrations clearly demonstrate the influence of the westerlies. Strong correlations are observed between fine sulphur concentrations and those of heavy metals such as Fe and Zn. Vertical profiles of heavy metal elements contained in marine particulates are also investigated at a trench in the Pacific Ocean and basins in the Japan Sea. Particulate element concentrations determined by PIXE agree well with those determined by chemical analysis of filtered/total water. Remarkable changes in depth profiles of particulate manganese are observed at the trench, which suggest horizontal transport of marine particulates from the trench wall. (N.K.)

  5. An environmental sampling model for combining judgment and randomly placed samples

    Energy Technology Data Exchange (ETDEWEB)

    Sego, Landon H.; Anderson, Kevin K.; Matzke, Brett D.; Sieber, Karl; Shulman, Stanley; Bennett, James; Gillen, M.; Wilson, John E.; Pulsipher, Brent A.

    2007-08-23

    In the event of the release of a lethal agent (such as anthrax) inside a building, law enforcement and public health responders take samples to identify and characterize the contamination. Sample locations may be rapidly chosen based on available incident details and professional judgment. To achieve greater confidence of whether or not a room or zone was contaminated, or to certify that detectable contamination is not present after decontamination, we consider a Bayesian model for combining the information gained from both judgment and randomly placed samples. We investigate the sensitivity of the model to the parameter inputs and make recommendations for its practical use.

  6. Measurement of actinides in environmental samples by Photo-Electron Rejecting Alpha Liquid Scintillation

    Energy Technology Data Exchange (ETDEWEB)

    Cadieux, J.R. [Westinghouse Savannah River Co., Aiken, SC (United States); Clark, S. [Savannah River Ecology Lab., Univ. of Georgia (United States); Fjeld, R.A.; Reboul, S.; Sowder, A. [Clemson Univ., SC (United States). Dept. of Environmental Systems Engineering

    1994-05-01

    This work describes the adaptation of extractive scintillation with a Photo-Electron Rejecting Alpha Liquid Scintillation (PERALS) (ORDELA, Inc.) spectrometer to the analysis of actinides in environmental samples from the Savannah River Site (SRS). Environmental quality assurance standards and actual water samples were treated by one of two methods; either a two step direct extraction, or for more complex samples, pretreatment by an extraction chromatographic separation prior to measurement of the alpha activity by PERALS.

  7. Guidance for establishment and implementation of field sample management programs in support of EM environmental sampling and analysis activities

    International Nuclear Information System (INIS)

    1994-01-01

    The role of the National Sample Management Program (NSMP) proposed by the Department of Energy's Office of Environmental Management (EM) is to be a resource for EM programs and for local Field Sample Management Programs (FSMPs). It will be a source of information on sample analysis and data collection within the DOE complex. The purpose of this document is to establish the suggested scope of the FSMP activities to be performed under each Operations Office, list the drivers under which the program will operate, define terms and list references. This guidance will apply only to EM sampling and analysis activities associated with project planning, contracting, laboratory selection, sample collection, sample transportation, laboratory analysis and data management

  8. Application of empore TM strontium rad disks to the analysis of radiostrontium in environmental water samples

    International Nuclear Information System (INIS)

    Smith, L.L.; Seely, D.C.; Shannon, R.T.

    1996-01-01

    A solid phase extraction method for analyzing radioactive strontium in surface, ground, and drinking waters is presented. Strontium is simply isolated by pulling an acidified sample aliquot through an Empore TM strontium rad disk with a vacuum, and the disk is subsequently assayed for beta activity. The method is efficient, safe, reliable, and potentially field deployable. Sample preparation and counting source preparation may be condensed into a single procedure, thereby improving efficiency and eliminating many potential sources of laboratory error. Moreover, many of the hazardous chemicals associated with traditional strontium procedures are eliminated. Samples are easily batched, and a one-liter sample may be prepared with as little as 20 min of effort. For a one-liter aqueous sample, up to 3 mg of strontium can be retained by the disks. Chemical and radiometric interferences are discussed. (orig.)

  9. Environmental sampling plan for Kwajalein Atoll Lagoon: 2017 Kwajalein sampling event

    Energy Technology Data Exchange (ETDEWEB)

    Hamilton, T. F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-07-01

    Since the early 1980s, the U.S DOE Marshall Islands Program at LLNL has provided radiological monitoring of the marine and terrestrial environment at nuclear affected atolls in the northern Marshall Islands. The fundamental aim of these studies was to identify the level and distribution of key residual fallout radionuclide in the environment, improve understanding of prevalent radiation exposure pathways, and develop predictive dose assessments for resettled and resettling atoll population groups. These data and information were essential in terms of guiding the development of effective and environmentally protective remedial measures, and promoting potential actions to improve on food safety and security.

  10. An overview of sample preparation procedures for LC-MS multiclass antibiotic determination in environmental and food samples.

    Science.gov (United States)

    Moreno-Bondi, María Cruz; Marazuela, María Dolores; Herranz, Sonia; Rodriguez, Erika

    2009-10-01

    Antibiotics are a class of pharmaceuticals that are of great interest due to the large volumes of these substances that are consumed in both human and veterinary medicine, and due to their status as the agents responsible for bacterial resistance. They can be present in foodstuffs and in environmental samples as multicomponent chemical mixtures that exhibit a wide range of mechanisms of action. Moreover, they can be transformed into different metabolites by the action of microorganisms, as well as by other physical or chemical means, resulting in mixtures with higher ecotoxicities and risks to human health than those of the individual compounds. Therefore, there is growing interest in the availability of multiclass methods for the analysis of antimicrobial mixtures in environmental and food samples at very low concentrations. Liquid chromatography (LC) has become the technique of choice for multiclass analysis, especially when coupled to mass spectrometry (LC-MS) and tandem MS (LC-MS(2)). However, due to the complexity of the matrix, in most cases an extraction step for sample clean-up and preconcentration is required before analysis in order to achieve the required sensitivities. This paper reviews the most recent developments and applications of multiclass antimicrobial determination in environmental and food matrices, emphasizing the practical aspects of sample preparation for the simultaneous extraction of antimicrobials from the selected samples. Future trends in the application of LC-MS-based techniques to multiclass antibiotic analysis are also presented.

  11. Validation of dipslides as a tool for environmental sampling in a real-life hospital setting

    DEFF Research Database (Denmark)

    Ibfelt, T; Foged, Charlotte Bernhardt Laiho; Andersen, L P

    2014-01-01

    for the dipslides and the TSA contact plate. Dipslides may be equally well suited for environmental sampling and hygiene assessment as TSA contact plates. Dipslides have some advantages, such as better sample security, easier sampling in confined spaces and longer shelf life that may speak in favour of choosing...

  12. Synthesis and Characterization of Mixed Iron-Manganese Oxide Nanoparticles and Their Application for Efficient Nickel Ion Removal from Aqueous Samples

    Science.gov (United States)

    Serra, Antonio; Monteduro, Anna Grazia; Padmanabhan, Sanosh Kunjalukkal; Licciulli, Antonio; Bonfrate, Valentina; Salvatore, Luca; Calcagnile, Lucio

    2017-01-01

    Mixed iron-manganese oxide nanoparticles, synthesized by a simple procedure, were used to remove nickel ion from aqueous solutions. Nanostructures, prepared by using different weight percents of manganese, were characterized by transmission electron microscopy, selected area diffraction, X-ray diffraction, Raman spectroscopy, and vibrating sample magnetometry. Adsorption/desorption isotherm curves demonstrated that manganese inclusions enhance the specific surface area three times and the pores volume ten times. This feature was crucial to decontaminate both aqueous samples and food extracts from nickel ion. Efficient removal of Ni2+ was highlighted by the well-known dimethylglyoxime test and by ICP-MS analysis and the possibility of regenerating the nanostructure was obtained by a washing treatment in disodium ethylenediaminetetraacetate solution. PMID:28804670

  13. Synthesis and Characterization of Mixed Iron-Manganese Oxide Nanoparticles and Their Application for Efficient Nickel Ion Removal from Aqueous Samples.

    Science.gov (United States)

    Buccolieri, Alessandro; Serra, Antonio; Maruccio, Giuseppe; Monteduro, Anna Grazia; Padmanabhan, Sanosh Kunjalukkal; Licciulli, Antonio; Bonfrate, Valentina; Salvatore, Luca; Manno, Daniela; Calcagnile, Lucio; Giancane, Gabriele

    2017-01-01

    Mixed iron-manganese oxide nanoparticles, synthesized by a simple procedure, were used to remove nickel ion from aqueous solutions. Nanostructures, prepared by using different weight percents of manganese, were characterized by transmission electron microscopy, selected area diffraction, X-ray diffraction, Raman spectroscopy, and vibrating sample magnetometry. Adsorption/desorption isotherm curves demonstrated that manganese inclusions enhance the specific surface area three times and the pores volume ten times. This feature was crucial to decontaminate both aqueous samples and food extracts from nickel ion. Efficient removal of Ni 2+ was highlighted by the well-known dimethylglyoxime test and by ICP-MS analysis and the possibility of regenerating the nanostructure was obtained by a washing treatment in disodium ethylenediaminetetraacetate solution.

  14. Synthesis and Characterization of Mixed Iron-Manganese Oxide Nanoparticles and Their Application for Efficient Nickel Ion Removal from Aqueous Samples

    Directory of Open Access Journals (Sweden)

    Alessandro Buccolieri

    2017-01-01

    Full Text Available Mixed iron-manganese oxide nanoparticles, synthesized by a simple procedure, were used to remove nickel ion from aqueous solutions. Nanostructures, prepared by using different weight percents of manganese, were characterized by transmission electron microscopy, selected area diffraction, X-ray diffraction, Raman spectroscopy, and vibrating sample magnetometry. Adsorption/desorption isotherm curves demonstrated that manganese inclusions enhance the specific surface area three times and the pores volume ten times. This feature was crucial to decontaminate both aqueous samples and food extracts from nickel ion. Efficient removal of Ni2+ was highlighted by the well-known dimethylglyoxime test and by ICP-MS analysis and the possibility of regenerating the nanostructure was obtained by a washing treatment in disodium ethylenediaminetetraacetate solution.

  15. A Simple and Selective Spectrophotometric Method for the Determination of Trace Gold in Real, Environmental, Biological, Geological and Soil Samples Using Bis (Salicylaldehyde Orthophenylenediamine

    Directory of Open Access Journals (Sweden)

    Rubina Soomro

    2008-01-01

    Full Text Available A simple high sensitive, selective, and rapid spectrophotometric method for the determination of trace gold based on the rapid reaction of gold(III with bis(salicylaldehydeorthophenylenediamine (BSOPD in aqueous and micellar media has been developed. BSOPD reacts with gold(III in slightly acidic solution to form a 1:1 brownish-yellow complex, which has an maximum absorption peak at 490 nm in both aqueous and micellar media. The most remarkable point of this method is that the molar absorptivities of the gold-BSOPD complex form in the presence of the nonionic TritonX-100 surfactant are almost a 10 times higher than the value observed in the aqueous solution, resulting in an increase in the sensitivity and selectivity of the method. The apparent molar absorptivities were found to be 2.3 × 104 L mol−1 cm−1 and 2.5 × 105 L mol−1 cm−1 in aqueous and micellar media, respectively. The reaction is instantaneous and the maximum absorbance was obtained after 10 min at 490 nm and remains constant for over 24 h at room temperature. The linear calibration graphs were obtained for 0.1 –30 mg L−1 and 0.01 –30 mg L−1 of gold(III in aqueous and surfactant media, respectively. The interference from over 50 cations, anions and complexing agents has been studied at 1 mg L−1 of Au(III; most metal ions can be tolerated in considerable amounts in aqueous micellar solutions. The Sandell’s sensitivity, the limit of detection and relative standard deviation (n = 9 were found to be 5 ng cm−2, 1 ng mL−1 and 2%, respectively in aqueous micellar solutions. Its sensitivity and selectivity are remarkably higher than that of other reagents in the literature. The proposed method was successfully used in the determination of gold in several standard reference materials (alloys and steels, environmental water samples (potable and polluted, and biological samples (blood and urine, geological, soil and complex synthetic mixtures. The results obtained agree

  16. Synthesis and Characterization of Mixed Iron-Manganese Oxide Nanoparticles and Their Application for Efficient Nickel Ion Removal from Aqueous Samples

    OpenAIRE

    Buccolieri, Alessandro; Serra, Antonio; Maruccio, Giuseppe; Monteduro, Anna Grazia; Padmanabhan, Sanosh Kunjalukkal; Licciulli, Antonio; Bonfrate, Valentina; Salvatore, Luca; Manno, Daniela; Calcagnile, Lucio; Giancane, Gabriele

    2017-01-01

    Mixed iron-manganese oxide nanoparticles, synthesized by a simple procedure, were used to remove nickel ion from aqueous solutions. Nanostructures, prepared by using different weight percents of manganese, were characterized by transmission electron microscopy, selected area diffraction, X-ray diffraction, Raman spectroscopy, and vibrating sample magnetometry. Adsorption/desorption isotherm curves demonstrated that manganese inclusions enhance the specific surface area three times and the por...

  17. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2008

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2008-01-01

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by Pacific Northwest National Laboratory for the U.S. Department of Energy. Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 450.1, "Environmental Protection Program," and DOE Order 5400.5, "Radiation Protection of the Public and the Environment." The environmental surveillance sampling design is described in the "Hanford Site Environmental Monitoring Plan, United States Department of Energy, Richland Operations Office." This document contains the calendar year 2008 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis. If a sample will not be collected in 2008, the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2008.

  18. Qualitative and quantitative analysis of environmental samples by laser-induced breakdown spectrometry

    International Nuclear Information System (INIS)

    Zorov, N B; Popov, A M; Zaytsev, S M; Labutin, T A

    2015-01-01

    The key achievements in the determination of trace amounts of components in environmental samples (soils, ores, natural waters, etc.) by laser-induced breakdown spectrometry are considered. Unique capabilities of this method make it suitable for rapid analysis of metals and alloys, glasses, polymers, objects of cultural heritage, archaeological and various environmental samples. The key advantages of the method that account for its high efficiency are demonstrated, in particular, a small amount of analyzed material, the absence of sample preparation, the possibility of local and remote analysis of either one or several elements. The use of chemometrics in laser-induced breakdown spectrometry for qualitative sample classification is described in detail. Various approaches to improving the figures of merit of quantitative analysis of environmental samples are discussed. The achieved limits of detection for most elements in geochemical samples are critically evaluated. The bibliography includes 302 references

  19. The role of data analysis in sampling design of environmental monitoring

    International Nuclear Information System (INIS)

    Shyr, L.J.; Herrera, H.; Haaker, R.

    1998-03-01

    The report is intended to address the need for data analysis in environmental sampling programs. Routine environmental sampling has been conducted at Sandia National Laboratories/New Mexico (SNL/NM) to ensure that site operations have not resulted in undue risk to the public and the environment. Over the years, large amounts of data have been accumulated. The richness of the data should be fully utilized to improve sampling design and prioritize sampling needs for a technically-sound, yet cost-effective sampling design. The report presents a methodology for analyzing environmental monitoring data and demonstrates the application by using SNL's historical monitoring data. Recommendations for sampling design modification were derived based on the results of the analyses

  20. Method validation and uncertainty evaluation of organically bound tritium analysis in environmental sample.

    Science.gov (United States)

    Huang, Yan-Jun; Zeng, Fan; Zhang, Bing; Chen, Chao-Feng; Qin, Hong-Juan; Wu, Lian-Sheng; Guo, Gui-Yin; Yang, Li-Tao; Shang-Guan, Zhi-Hong

    2014-08-01

    The analytical method for organically bound tritium (OBT) was developed in our laboratory. The optimized operating conditions and parameters were established for sample drying, special combustion, distillation, and measurement on a liquid scintillation spectrometer (LSC). Selected types of OBT samples such as rice, corn, rapeseed, fresh lettuce and pork were analyzed for method validation of recovery rate reproducibility, the minimum detection concentration, and the uncertainty for typical low level environmental sample was evaluated. The combustion water recovery rate of different dried environmental sample was kept at about 80%, the minimum detection concentration of OBT ranged from 0.61 to 0.89 Bq/kg (dry weight), depending on the hydrogen content. It showed that this method is suitable for OBT analysis of environmental sample with stable recovery rate, and the combustion water yield of a sample with weight about 40 g would provide sufficient quantity for measurement on LSC. Copyright © 2014 Elsevier Ltd. All rights reserved.

  1. Detection of pyrethroid pesticides and their environmental degradation products in duplicate diet samples

    Science.gov (United States)

    The abstract is for an oral presentation at the Asilomar Conference on Mass Spectrometry: Mass Spectrometry in Environmental Chemistry, Toxicology, and Health. It describes analytical method development and sample results for determination of pyrethroid pesticides and environme...

  2. Engineering Task Plan to Expand the Environmental Operational Envelope of Core Sampling

    International Nuclear Information System (INIS)

    BOGER, R.M.

    1999-01-01

    This Engineering Task Plan authorizes the development of an Alternative Generation and Analysis (AGA). The AGA will determine how to expand the environmental operating envelope during core sampling operations

  3. Determination of natural alpha-emitting isotopes of uranium and thorium in environmental and geological samples

    International Nuclear Information System (INIS)

    Crespo, M.T.

    1996-01-01

    It is described the complete radiochemical procedure used for the determination of uranium and thorium isotopes in environmental and geological samples by alpha spectrometry. Source preparation methods, alpha-counting and spectral analysis are also included

  4. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2010

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2010-01-08

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by Pacific Northwest National Laboratory for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford Site environs per regulatory requirements. This document contains the calendar year 2010 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and the Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis. If a sample will not be collected in 2010, the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2010.

  5. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2009

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2009-01-20

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory for the U.S. Department of Energy. Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs, as required in DOE Order 450.1 and DOE Order 5400.5. This document contains the calendar year 2009 schedule for the routine collection of samples for the Surface Environmental Surveillance Project and Drinking Water Monitoring Project. Each section includes sampling locations, sampling frequencies, sample types, and analyses to be performed. In some cases, samples are scheduled on a rotating basis. If a sample will not be collected in 2009, the anticipated year for collection is provided. Maps showing approximate sampling locations are included for media scheduled for collection in 2009.

  6. Hanford Site Environmental Surveillance Master Sampling Schedule for Calendar Year 2005

    Energy Technology Data Exchange (ETDEWEB)

    Bisping, Lynn E.

    2005-01-19

    Environmental surveillance of the Hanford Site and surrounding areas is conducted by the Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE). Sampling is conducted to evaluate levels of radioactive and nonradioactive pollutants in the Hanford environs. This document contains the calendar year 2005 schedules for the routine and non-routine collection of samples for the Surface Environmental Surveillance Project (SESP) and Drinking Water Monitoring Project.

  7. Rapid Filtration Separation-Based Sample Preparation Method for Bacillus Spores in Powdery and Environmental Matrices

    OpenAIRE

    Isabel, Sandra; Boissinot, Maurice; Charlebois, Isabelle; Fauvel, Chantal M.; Shi, Lu-E; Lévesque, Julie-Christine; Paquin, Amélie T.; Bastien, Martine; Stewart, Gale; Leblanc, Éric; Sato, Sachiko; Bergeron, Michel G.

    2012-01-01

    Authorities frequently need to analyze suspicious powders and other samples for biothreat agents in order to assess environmental safety. Numerous nucleic acid detection technologies have been developed to detect and identify biowarfare agents in a timely fashion. The extraction of microbial nucleic acids from a wide variety of powdery and environmental samples to obtain a quality level adequate for these technologies still remains a technical challenge. We aimed to develop a rapid and versat...

  8. Green Aspects of Techniques for the Determination of Currently Used Pesticides in Environmental Samples

    OpenAIRE

    Maciej Tankiewicz; Jacek Namieśnik; Jolanta Stocka; Marek Biziuk

    2011-01-01

    Pesticides are among the most dangerous environmental pollutants because of their stability, mobility and long-term effects on living organisms. Their presence in the environment is a particular danger. It is therefore crucial to monitor pesticide residues using all available analytical methods. The analysis of environmental samples for the presence of pesticides is very difficult: the processes involved in sample preparation are labor-intensive and time-consuming. To date, it has been standa...

  9. Bacillus thuringiensis var. israelensis immobilized on Chromosorb 101: A new solid phase extractant for preconcentration of heavy metal ions in environmental samples

    International Nuclear Information System (INIS)

    Mendil, Durali; Tuzen, Mustafa; Usta, Canan; Soylak, Mustafa

    2008-01-01

    Bacillus thuringiensis var. israelensis immobilized on Chromosorb 101 that is a new solid phase extractor has been presented at this work for the preconcentration and separation of cadmium(II), lead(II), manganese(II), chromium(III), nickel(II) and cobalt(II) in environmental samples. The analytical parameters including pH of aqueous solutions, sample volume, eluent types, etc. were investigated for the quantitative recoveries of the analytes. The influences of the some metal ions as concomitant were investigated. Under the optimized conditions, the detection limits by 3σ for analyte ions were in the range of 0.37-2.85 μg L -1 . The accuracy of the developed procedure was confirmed by IAEA 336 Lichen and NIST SRM 1573a Tomato leaves certified reference materials. The method was also applied successfully to the determination of analytes in microwave digested red wine, rice and canned fish samples and sea water, spring water and urine samples

  10. A LC-MS method allowing the analysis of HMX and RDX present at the picogram level in natural aqueous samples without a concentration step.

    Science.gov (United States)

    Vigneau, Olivier; Machuron-Mandard, Xavier

    2009-03-15

    The introduction of chloroform into the nebulising gas of a LC/MS electrospray interface (ESI), in a perfectly controlled way, leads to the formation of intense adducts ([M+Cl](-)) when a mobile phase containing HMX (1,3,5,7-tetranitro-1,3,5,7-tetrazacyclooctane or octogen) and RDX (1,3,5-trintro-1,3,5-triazacyclohexane or hexogen) is eluted. This LC/MS method allows the direct analysis of aqueous samples containing HMX and RDX at the pictogram level without a concentration step. The method is used to determine HMX and RDX concentrations in ground water samples from a military site.

  11. Joint sampling programme-Verification of data obtained in environmental monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Lauria, D.C. [Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear, Av. Salvador Allende s/no., CEP 22780-160, Rio de Janeiro, RJ (Brazil)], E-mail: dejanira@ird.gov.br; Martins, N.S.F.; Vasconcellos, M.L.H.; Zenaro, R.; Peres, S.S.; Pires do Rio, M.A. [Instituto de Radioprotecao e Dosimetria, Comissao Nacional de Energia Nuclear, Av. Salvador Allende s/no., CEP 22780-160, Rio de Janeiro, RJ (Brazil)

    2008-11-15

    The objective of the Environmental Radiological Monitoring Control programme carried out by the Institute of Radiation Protection and Dosimetry (IRD) in Brazil is to verify the licensee's compliance with the requirements for environmental monitoring of Brazilian facilities. The Joint Sampling Programme (JSP) is just one part of the control programme. In order to verify that the data reported by the licensees is representative and legitimate, this programme verifies sampling procedures, accuracy and precision of the data and the changes in the environmental conditions. This paper discusses the main findings of this programme that allowed IRD to optimize its available resources to control the monitoring of the eight facilities in Brazil.

  12. Solvent-assisted dispersive solid-phase extraction: A sample preparation method for trace detection of diazinon in urine and environmental water samples.

    Science.gov (United States)

    Aladaghlo, Zolfaghar; Fakhari, Alireza; Behbahani, Mohammad

    2016-09-02

    In this research, a sample preparation method termed solvent-assisted dispersive solid-phase extraction (SA-DSPE) was applied. The used sample preparation method was based on the dispersion of the sorbent into the aqueous sample to maximize the interaction surface. In this approach, the dispersion of the sorbent at a very low milligram level was received by inserting a solution of the sorbent and disperser solvent into the aqueous sample. The cloudy solution created from the dispersion of the sorbent in the bulk aqueous sample. After pre-concentration of the diazinon, the cloudy solution was centrifuged and diazinon in the sediment phase dissolved in ethanol and determined by gas chromatography-flame ionization detector. Under the optimized conditions (pH of solution=7.0, Sorbent: benzophenone, 2%, Disperser solvent: ethanol, 500μL, Centrifuge: centrifuged at 4000rpm for 3min), the method detection limit for diazinon was 0.2, 0.3, 0.3 and 0.3μgL(-1) for distilled water, lake water, waste water and urine sample, respectively. Furthermore, the pre-concentration factor was 363.8, 356.1, 360.7 and 353.38 in distilled water, waste water, lake water and urine sample, respectively. SA-DSPE was successfully used for trace monitoring of diazinon in urine, lake and waste water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Tritium concentrations in environmental water and food samples collected around the vicinity of the PNPP-1

    International Nuclear Information System (INIS)

    Garcia, T.Y.; Enriquez, S.O.; Duran, E.B.

    1986-01-01

    The natural radioactivity levels of tritium in environmental samples collected around the vicinity and more distant environment of the first Philippine Nuclear Power Plant (PNPP-1) in Bataan were assessed. The samples analyzed consisted of water samples such as seawater, freshwater, drinking water, groundwater and rainwater; and food samples such as cereals, vegetables, fruits; meat, milk fish and crustaceans. Tritium concentrations in water samples were determined by distillation and liquid scintillation counting techniques. The food samples were analyzed for tissue-free water tritium by the freezing-drying method followed by liquid scintillation counting techniques. (Auth.) 13 refs

  14. Simultaneous quantification of polar and non-polar volatile organic compounds in water samples by direct aqueous injection-gas chromatography/mass spectrometry.

    Science.gov (United States)

    Aeppli, Christoph; Berg, Michael; Hofstetter, Thomas B; Kipfer, Rolf; Schwarzenbach, René P

    2008-02-15

    A direct aqueous injection-gas chromatography/mass spectrometry (DAI-GC/MS) method for trace analysis of 24 volatile organic compounds (VOCs) in water samples is presented. The method allows for the simultaneous quantification of benzene, toluene, ethyl benzene, and xylenes (BTEX), methyl tert-butyl ether (MTBE), tert-butyl alcohol (TBA), as well as a variety of chlorinated methanes, ethanes, propane, enthenes and benzenes. Applying a liquid film polyethylene glycol or a porous layer open tubular (PLOT) divinylbenzene GC capillary column to separate the water from the VOCs, volumes of 1-10 microL aqueous sample are directly injected into the GC. No enrichment or pretreatment steps are required and sample volumes as low as 100 microL are sufficient for accurate quantification. Method detection limits determined in natural groundwater samples were between 0.07 and 2.8 microg/L and instrument detection limits of VOCs. DAI-GC/MS offers both good accuracy and precision (relative standard deviations VOC concentration measurements in a polluted aquifer. The wide range of detectable compounds and the lack of labor-intensive sample preparation illustrate that the DAI method is robust and easily applicable for the quantification of important organic groundwater contaminants.

  15. Sorption potential of alkaline treated straw and a soil for sulfonylurea herbicide removal from aqueous solutions: An environmental management strategy.

    Science.gov (United States)

    Cara, Irina-Gabriela; Rusu, Bogdan-George; Raus, Lucian; Jitareanu, Gerard

    2017-11-01

    The adsorption potential of alkaline treated straw (wheat and corn) in mixture with soil, has been investigated for the removal of sulfonylurea molecules from an aqueous solutions. The surface characteristics were investigated by scanning electron microscopy and Fourier Transform Infrared - FTIR, while the adsorbent capacity was evaluated using batch sorption tests and liquid chromatography coupled with mass spectrometry. Surface analysis of alkaline treated straw samples by scanning electron microscopy - SEM showed the increasing of the surface roughness improving their functional surface activity. An increase (337.22 mg g -1 ) of adsorption capacity of sulfonylurea molecules was obtained for all studied straw. The Langmuir isotherm model was the best model for the mathematical description of the adsorption process indicating the forming of a surface sorption monolayer with a finite number of identical sites. The kinetics of sulfonylurea herbicide followed the pseudo-second order mechanism corresponding to strong chemical interactions. The results sustained that the alkaline treated straw have biosorption characteristics, being suitable adsorbent materials. Copyright © 2017 Elsevier Ltd. All rights reserved.

  16. Report for Detection of Biothreat Agents and Environmental Samples using the LLNL Virulence Array for DHS

    Energy Technology Data Exchange (ETDEWEB)

    Jaing, Crystal [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Gardner, Shea [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); McLoughlin, Kevin [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Thissen, James [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Jackson, Paul [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2011-04-18

    The objective of this project is to provide DHS a comprehensive evaluation of the current genomic technologies including genotyping, Taqman PCR, multiple locus variable tandem repeat analysis (MLVA), microarray and high-throughput DNA sequencing in the analysis of biothreat agents from complex environmental samples. This report focuses on the design, testing and results of samples on the Virulence Array.

  17. Rapid filtration separation-based sample preparation method for Bacillus spores in powdery and environmental matrices.

    Science.gov (United States)

    Isabel, Sandra; Boissinot, Maurice; Charlebois, Isabelle; Fauvel, Chantal M; Shi, Lu-E; Lévesque, Julie-Christine; Paquin, Amélie T; Bastien, Martine; Stewart, Gale; Leblanc, Eric; Sato, Sachiko; Bergeron, Michel G

    2012-03-01

    Authorities frequently need to analyze suspicious powders and other samples for biothreat agents in order to assess environmental safety. Numerous nucleic acid detection technologies have been developed to detect and identify biowarfare agents in a timely fashion. The extraction of microbial nucleic acids from a wide variety of powdery and environmental samples to obtain a quality level adequate for these technologies still remains a technical challenge. We aimed to develop a rapid and versatile method of separating bacteria from these samples and then extracting their microbial DNA. Bacillus atrophaeus subsp. globigii was used as a simulant of Bacillus anthracis. We studied the effects of a broad variety of powdery and environmental samples on PCR detection and the steps required to alleviate their interference. With a benchmark DNA extraction procedure, 17 of the 23 samples investigated interfered with bacterial lysis and/or PCR-based detection. Therefore, we developed the dual-filter method for applied recovery of microbial particles from environmental and powdery samples (DARE). The DARE procedure allows the separation of bacteria from contaminating matrices that interfere with PCR detection. This procedure required only 2 min, while the DNA extraction process lasted 7 min, for a total of sample preparation procedure allowed the recovery of cleaned bacterial spores and relieved detection interference caused by a wide variety of samples. Our procedure was easily completed in a laboratory facility and is amenable to field application and automation.

  18. Methodology of testing environmental samples from the area surrounding radioactive waste deposits

    International Nuclear Information System (INIS)

    Kropikova, S.; Pastuchova, D.

    1979-01-01

    Methods are described of environmental sample investigation in the area surrounding radioactive waste deposits, namely monitoring ground water, surface water, sediments, water flows and catchments, vegetation and soil. Methods of sample preparation, and methods of radionuclides determination in mixtures are also discussed, as are spot activity measurement methods. (author)

  19. Geographical Information Systems (GIS) Mapping of Environmental Samples across College Campuses

    Science.gov (United States)

    Purvis-Roberts, Kathleen L.; Moeur, Harriet P.; Zanella, Andrew

    2007-01-01

    In this laboratory experiment, students take environmental samples at various locations around the college campuses, take geospatial coordinates with a global position systems (GPS) unit, and map their results on a geo-referenced campus map with geographical information systems (GIS) software. Nitrogen dioxide air pollution sampling is used as an…

  20. Fast identification of microplastics in complex environmental samples by a thermal degradation method.

    Science.gov (United States)

    Dümichen, Erik; Eisentraut, Paul; Bannick, Claus Gerhard; Barthel, Anne-Kathrin; Senz, Rainer; Braun, Ulrike

    2017-05-01

    In order to determine the relevance of microplastic particles in various environmental media, comprehensive investigations are needed. However, no analytical method exists for fast identification and quantification. At present, optical spectroscopy methods like IR and RAMAN imaging are used. Due to their time consuming procedures and uncertain extrapolation, reliable monitoring is difficult. For analyzing polymers Py-GC-MS is a standard method. However, due to a limited sample amount of about 0.5 mg it is not suited for analysis of complex sample mixtures like environmental samples. Therefore, we developed a new thermoanalytical method as a first step for identifying microplastics in environmental samples. A sample amount of about 20 mg, which assures the homogeneity of the sample, is subjected to complete thermal decomposition. The specific degradation products of the respective polymer are adsorbed on a solid-phase adsorber and subsequently analyzed by thermal desorption gas chromatography mass spectrometry. For certain identification, the specific degradation products for the respective polymer were selected first. Afterwards real environmental samples from the aquatic (three different rivers) and the terrestrial (bio gas plant) systems were screened for microplastics. Mainly polypropylene (PP), polyethylene (PE) and polystyrene (PS) were identified for the samples from the bio gas plant and PE and PS from the rivers. However, this was only the first step and quantification measurements will follow. Copyright © 2017 Elsevier Ltd. All rights reserved.

  1. Rapid determination of bacterial aminoglycoside resistance in environmental samples using membrane electrospray ionization mass spectrometry.

    Science.gov (United States)

    Fan, Liusheng; Ke, Ming; Yuan, Min; Pu, Ji; Li, Juan; Lu, Jinxing; Xu, Jianguo; Zhang, Mei; Xu, Wei

    2016-08-01

    Antibiotic resistance in pathogenic bacteria is becoming a global public health problem, such as aminoglycoside resistance encoded by the armA gene. Although many methods have been reported, rapid analysis of environmental samples is still challenging. A rapid analytical method was developed in this study to determine bacterial aminoglycoside resistance using membrane electrospray ionization mass spectrometry (MESI-MS). Precursor/product-ion pairs of ArmA unique peptides were detected with minimal sample preparation. Standard peptides were synthesized and used for developing and validating the methodology, and then the method was verified by both ArmA positive and ArmA negative simulated environmental samples. A rapid method for determination of bacterial aminoglycoside resistance was developed using MESI-MS/MS. The bacterial cultural time was optimized to 2 hours, and the precision, accuracy and recovery of this method were investigated. The peptide IHSSTNER (IR-8) unique to ArmA in simulated environmental samples can be successfully identified within 3 hours. The novel assay offered a rapid method to determine bacterial aminoglycoside resistance with high sensitivity, accuracy and precision in simulated environmental samples. This method could also be applied to identify other drug-resistance proteins in clinical/environmental samples. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

  2. Matrix effects and recovery calculations in analyses of pharmaceuticals based on the determination of β-blockers and β-agonists in environmental samples.

    Science.gov (United States)

    Caban, Magda; Migowska, Natalia; Stepnowski, Piotr; Kwiatkowski, Marek; Kumirska, Jolanta

    2012-10-05

    In recent years substantial progress has been made in analytical methods for determining pharmaceutical residues in environmental samples. Although much work has attempted to establish the influence of sample matrix complexity on results through the determination of matrix effects (ME), extraction efficiency (EE) and absolute recovery of analytes (AR), comparison of these parameters is very complicated because different authors use different methods to obtain them. Moreover, there are few literature data describing the influence of aqueous matrices (tap water and waste water) on results obtained with GC-MS methods. For these reasons, the main aims of the present study were: (1) to critically review the determination of matrix effects and recovery parameters using the two most common techniques for analyzing drugs in environmental samples: gas and liquid chromatography coupled with mass spectrometry or tandem mass spectrometry (GC-MS, GC-MS/MS and LC-MS, LC-MS/MS); (2) to postulate a uniform method for determining ME, EE and AR using GC techniques; (3) to investigate the influence of different aqueous matrices on the solid-phase extraction, derivatization and final determination of drugs using GC. β-Blockers and β-agonists, drugs commonly found in the environment, were chosen as model compounds for this investigation. The values of ME, EE and AR obtained were compared with analogous (or similar) data obtained by other researchers using LC-MS measurements. All the results confirmed that GC-MS analyses are much less sensitive to the complexity of sample matrices than LC-MS, so GC-MS measurements appear to be a very good alternative to LC-MS methods of determining pharmaceutical residues in environmental samples. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. State of the art of environmentally friendly sample preparation approaches for determination of PBDEs and metabolites in environmental and biological samples: A critical review.

    Science.gov (United States)

    Berton, Paula; Lana, Nerina B; Ríos, Juan M; García-Reyes, Juan F; Altamirano, Jorgelina C

    2016-01-28

    Green chemistry principles for developing methodologies have gained attention in analytical chemistry in recent decades. A growing number of analytical techniques have been proposed for determination of organic persistent pollutants in environmental and biological samples. In this light, the current review aims to present state-of-the-art sample preparation approaches based on green analytical principles proposed for the determination of polybrominated diphenyl ethers (PBDEs) and metabolites (OH-PBDEs and MeO-PBDEs) in environmental and biological samples. Approaches to lower the solvent consumption and accelerate the extraction, such as pressurized liquid extraction, microwave-assisted extraction, and ultrasound-assisted extraction, are discussed in this review. Special attention is paid to miniaturized sample preparation methodologies and strategies proposed to reduce organic solvent consumption. Additionally, extraction techniques based on alternative solvents (surfactants, supercritical fluids, or ionic liquids) are also commented in this work, even though these are scarcely used for determination of PBDEs. In addition to liquid-based extraction techniques, solid-based analytical techniques are also addressed. The development of greener, faster and simpler sample preparation approaches has increased in recent years (2003-2013). Among green extraction techniques, those based on the liquid phase predominate over those based on the solid phase (71% vs. 29%, respectively). For solid samples, solvent assisted extraction techniques are preferred for leaching of PBDEs, and liquid phase microextraction techniques are mostly used for liquid samples. Likewise, green characteristics of the instrumental analysis used after the extraction and clean-up steps are briefly discussed. Copyright © 2015 Elsevier B.V. All rights reserved.

  4. Radiochemical separation of actinides for their determination in environmental samples and waste products

    Energy Technology Data Exchange (ETDEWEB)

    Gleisberg, B. [Nuclear Engineering and Analytics Rossendorf, Inc. (VKTA), Dresden (Germany)

    1997-03-01

    The determination of low level activities of actinides in environmental samples and waste products makes high demands on radiochemical separation methods. Artificial and natural actinides were analyzed in samples form the surrounding areas of NPP and of uranium mines, incorporation samples, solutions containing radioactive fuel, solutions and solids resutling from the process, and in wastes. The activities are measured by {alpha}-spectrometry and {gamma}-spectrometry. (DG)

  5. Nontuberculous Mycobacteria Isolation from Clinical and Environmental Samples in Iran: Twenty Years of Surveillance

    Directory of Open Access Journals (Sweden)

    Ali Akbar Velayati

    2015-01-01

    Full Text Available Nontuberculous mycobacteria (NTM are opportunistic pathogens that are widely distributed in the environment. There is a lack of data on species distribution of these organisms from Iran. This study consists of a review of NTM articles published in Iran between the years 1992 and 2014. In this review, 20 articles and 14 case reports were identified. Among the 20 articles, 13 (65% studies focused on NTM isolates from clinical specimens, 6 (30% studies examined NTM isolates from environmental samples, and one (5% article included both clinical and environmental isolates. M. fortuitum (229/997; 23% was recorded as the most prevalent and rapid growing mycobacteria (RGM species in both clinical (28% and environmental (19% isolated samples (P < 0.05. Among slow growing mycobacteria (SGM, M. simiae (103/494; 21% demonstrated a higher frequency in clinical samples whereas in environmental samples it was M. flavescens (44/503; 9%. These data represent information from 14 provinces out of 31 provinces of Iran. No information is available in current published data on clinical or environmental NTM from the remaining 17 provinces in Iran. These results emphasize the potential importance of NTM as well as the underestimation of NTM frequency in Iran. NTM is an important clinical problem associated with significant morbidity and mortality in Iran. Continued research is needed from both clinical and environmental sources to help clinicians and researchers better understand and address NTM treatment and prevention.

  6. The analysis study of plutonium in the environmental sample by mass spectrum combined with isotopic dilution

    International Nuclear Information System (INIS)

    Han Jun; Fu Zhonghua; Mao Xingen; Meng Fanben

    2004-01-01

    The technology of the rhenium filament carbonization was used to increase the ionization efficiency in this paper. The plutonium in the environmental sample was analyzed by Mass Spectrum combined with isotope dilution. Analysis of the 239 Pu blank in the process: The analysis of 239 Pu from the chemical process was carried out in order to establish the influence of the 239 Pu introduced from the process. The analysis results were shown in Table 1 sample 1 was not gone through the process, sample 2 and sample 3 were gone through the process. It was clear that there was no influence of the 239 Pu from the process within the deviation. Results and Discussions: The environmental samples which were dealed with the chemical method were prepared the sample of mass spectrum, The atomic ratio of the 239 Pu and 242 Pu in the environmental samples was measured by Mass Spectrum. The atomic ratio in the tracer 242 Pu was 0.01476±0.00007.The results for nuclide content in environment were given in Table 2. The content of 239 Pu in the tracer was high, so the existing of 239 Pu in the environmental samples can be determined by the changing of the atomic ratio of 242 Pu to 239 Pu. It was clear that there was 239 Pu in the environmental samples except the cypress leaves-2 and the pine leaves-3 within the deviation, and the content of 239 Pu were given in Table 2. Conclusion: a. Plutonium was separated and purified from the impurity by the anion-exchange and the electrodeposition, it was possible to provide the eligible mass spectrum sample. b. The measurement of plutonium in the environmental samples was not influenced by the flow of the background in the experiment. c. As the technology of the rhenium carbonization was used to increase the ionization efficiency, the content of plutonium which was about 10 -13 g in the environmental sample could be quantitatively analyzed by Mass Spectrum combined with isotope dilution. (authors)

  7. Open focused microwave-assisted sample preparation for rapid total and mercury species determination in environmental solid samples.

    Science.gov (United States)

    Tseng, C M; Garraud, H; Amouroux, D; Donard, O F; de Diego, A

    1998-01-01

    This paper describes rapid, simple microwave-assisted leaching/ digestion procedures for total and mercury species determination in sediment samples and biomaterials. An open focused microwave system allowed the sample preparation time to be dramatically reduced to only 24 min when a power of 40-80 W was applied. Quantitative leaching of methylmercury from sediments by HNO(3) solution and complete dissolution of biomaterials by an alkaline solution, such as 25% TMAH solution, were obtained. Methylmercury compounds were kept intact without decomposition or losses by evaporation. Quantitative recoveries of total mercury were achieved with a two-step microwave attack using a combination of HNO(3) and H(2)0(2) solutions as extractant. The whole pretreatment procedure only takes 15 min, which can be further shortened by an automated robust operation with an open focused system. These analytical procedures were validated by the analysis of environmental certified reference materials. The results confirm that the open focused microwave technique is a promising tool for solid sample preparation in analytical and environmental chemistry.

  8. Determination of estrogenic mycotoxins in environmental water samples by low-toxicity dispersive liquid-liquid microextraction and liquid chromatography-tandem mass spectrometry.

    Science.gov (United States)

    Emídio, Elissandro Soares; da Silva, Claudia Pereira; de Marchi, Mary Rosa Rodrigues

    2015-04-24

    A novel, simple, rapid and eco-friendly method based on dispersive liquid-liquid microextraction using a bromosolvent was developed to determine six estrogenic mycotoxins (zearalenone, zearalanone, α-zearalanol, β-zearalanol, α-zearalenol and β-zearalenol) in water samples by liquid chromatography-electrospray ionization tandem mass spectrometry in the negative mode (LC-ESI-MS/MS). The optimal conditions for this method include the use of 100 μL bromocyclohexane as an extraction solvent (using a non-dispersion solvent), 10 mL of aqueous sample (adjusted to pH 4), a vortex extraction time of 2 min, centrifugation for 10 min at 3500 rpm and no ionic strength adjustment. The calibration function was linear and was verified by applying the Mandel fitting test with a 95% confidence level. No matrix effect was observed. According to the relative standard deviations (RSDs), the precision was better than 13% for the repeatability and intermediate precision. The average recoveries of the spiked compounds ranged from 81 to 118%. The method limits of detection (LOD) and quantification (LOQ) considering a 125-fold pre-concentration step were 4-20 and 8-40 ng L(-1), respectively. Next, the method was applied to the analysis of the environmental aqueous samples, demonstrating the presence of β-zearalanol and zearalanone in the river water samples. Copyright © 2015 Elsevier B.V. All rights reserved.

  9. Evaluation of oxidation techniques for preparing bioassay and environmental samples for liquid scintillation counting

    International Nuclear Information System (INIS)

    Miller, H.H.

    1979-10-01

    In environmental and biological monitoring for carbon-14 and tritium, the presence of color and chemical quenching agents in the samples can degrade the efficiency of liquid scintillation counting. A series of experiments was performed to evaluate the usefulness, under routine conditions, of first oxidizing the samples to improve the counting by removing the color and quenching agents. The scintillation counter was calibrated for the effects of quenching agents on its counting efficiency. Oxidizing apparatus was tested for its ability to accurately recover the 14 C and 3 H in the samples. Scintillation counting efficiences were compared for a variety of oxidized and unoxidized environmental and bioassay samples. The overall conclusion was that, for routine counting, oxidation of such samples is advantageous when they are highly quenched or in solid form

  10. Study on auto-plating process time versus recovery for polonium, Po-210 in environmental sample

    International Nuclear Information System (INIS)

    Jalal Sharib; Zaharudin Ahmad; Abdul Kadir Ishak; Norfaizal Mohamed; Ahmad Sanadi Abu Bakar; Yii Mei Wo; Kamarozaman Ishak; Siti Aminah Yusoff

    2008-08-01

    This study was carried out to evaluate time effectiveness and recovery 16 samples of 4 Kuala Muda stations during auto-plating process procedures for determination Polonium, Po 210 activity concentration in environmental sample. The study was performed using Kuala Muda sediment as sample in the same methodology. The auto-plating process runs for 4, 12, 24 and 30 hours on a silver disc for 4 samples each station, and then counted for one (1) day using an alpha spectrometry counting system. The objectives for this study is to justify on time duration for auto-plating process effecting a chemical yield of Po-209.The results showed recovery are increasing versus time and constantly at 24 hour auto-plating. Its mean, 24 hour is an optimum time for auto-plating process for determination of Polonium, Po 210 activity concentration in environmental sample. (Author)

  11. Use of immunomagnetic separation for the detection of Desulfovibrio vulgaris from environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Chakraborty, R.; Hazen, T.C.; Joyner, D.C.; Kusel, K.; Singer, M.E.; Sitte, J.; Torok, T.

    2011-04-15

    Immunomagnetic separation (IMS) has proved highly efficient for recovering microorganisms from heterogeneous samples. Current investigation targeted the separation of viable cells of the sulfate-reducing bacterium, Desulfovibrio vulgaris. Streptavidin-coupled paramagnetic beads and biotin labeled antibodies raised against surface antigens of this microorganism were used to capture D. vulgaris cells in both bioreactor grown laboratory samples and from extremely low-biomass environmental soil and subsurface drilling samples. Initial studies on detection, recovery efficiency and viability for IMS were performed with laboratory grown D. vulgaris cells using various cell densities. Efficiency of cell isolation and recovery (i.e., release of the microbial cells from the beads following separation) was followed by microscopic imaging and acridine orange direct counts (AODC). Excellent recovery efficiency encouraged the use of IMS to capture Desulfovibrio spp. cells from low-biomass environmental samples. The environmental samples were obtained from a radionuclide-contaminated site in Germany and the chromium (VI)-contaminated Hanford site, an ongoing bioremediation project of the U.S. Department of Energy. Field deployable IMS technology may greatly facilitate environmental sampling and bioremediation process monitoring and enable transcriptomics and proteomics/metabolomics-based studies directly on cells collected from the field.

  12. Tritium analysis in environmental samples around Nuclear Power Plants and nationwide surveillance of radionuclides in some environmental samples(meat and drinking water)

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Yong Woo; Han, Man Jung; Cho, Seong Won; Cho, Hong Jun; Oh, Hyeon Kyun; Lee, Jeong Min; Chang, Jae Sook [KORTIC, Taejon (Korea, Republic of)

    2001-12-15

    12 kind of environmental samples such as soil, underground water, seawater, etc. around the Nuclear Power Plants(NPP) and surface seawater around the Korea peninsula were sampled, For the samples of rain, pine-needle, air, seawater, underground water, chinese cabbage, grain of rice and milk sampled around NPP, and surface seawater and rain sampled all around country, tritium concentration was measured, The tritium concentration in the tap water and the gamma activity in the domestic and imported beef that were sampled at ward in the large city in Korea(Seoul, Pusan, Taegu, Taejun, Inchun, Kwangju) were analyzed for the meat and drinking waters. As the results of analyzing, tritium concentration in rain and tap water were very low all around country, but a little higher around the NPP than general surrounding. At the Wolsung NPP, tritium concentration was descend according to distance from the stack. Tritium activity of surface seawater around the Korea peninsula was also, very low. The measured radioactive elements in the beef is the same as the radioactive elements on the earth surface.

  13. Preparedness Procedure and Environmental Radionuclides Sampling Measurement and Monitoring in Malaysia caused from Fukushima Nuclear Accident

    International Nuclear Information System (INIS)

    Nur Azna Mahmud; Zalina Laili; Muhamat Omar

    2011-01-01

    Nuclear accident in Fukushima, Japan, had caused the release of the radioactive material into the air. Our environment might be contaminated through radioactive fallout. Thus, environmental monitoring programme was activated after the accident covering areas that might be affected. Coordination of actions was made among the relevant agencies to face the emergency situation. Sample analysis was carried out by Nuklear Malaysia on environmental samples consist of rain water, sand, flora and fauna were collected and analysed using gamma spectrometer systems. This analysis was intended to measure the activity concentration of the fission products such as I-131, Cs-134 and Cs-137. Thus, a standard procedure for measurement has been developed in order to analyse the environmental samples from this emergency case. This procedure can be used as a reference in the future when such emergency situation occurs. (author)

  14. Paraffin surfaces for culture-based detection of mycobacteria in environmental samples

    Science.gov (United States)

    Jing, Gaoshan; Eluru, Hima B.; Polaczyk, Amy; Kinkle, Brian; Oerther, Daniel B.; Papautsky, Ian

    2005-02-01

    In this paper, we describe the development of paraffin surfaces for culture-based detection of mycobacteria in environmental samples. The surfaces use the well-described paraffinophilic nature of mycobacteria to rapidly and selectively differentiate them from non-target microorganisms. New methods of depositing and patterning paraffin were developed, including using butanol or a heat gun to generate molten paraffin that was subsequently deposited by spin coating and patterned by wet and dry etching techniques. Using these techniques, 18 mm glass wafers with paraffin films of 10 70 µm were fabricated and subsequently etched to form different patterns. Prototype paraffin surfaces were experimentally tested to demonstrate the concept of rapid and selective detection of mycobacteria in environmental samples collected from a municipal sewage treatment plant. Our successful demonstration of the culture-based detection on paraffin substrates presents an alternative approach for tracking microorganisms in complex environmental samples.

  15. The association of Salmonella enterica from aquatic environmental and clinical samples in Taiwan.

    Science.gov (United States)

    Ho, Ying-Ning; Tsai, Hsin-Chi; Hsu, Bing-Mu; Chiou, Chien-Shun

    2018-05-15

    Salmonella is one of the most common pathogens of waterborne and foodborne disease-causing pathogens. In this study, we collected 172 surface water samples from Puzih River and Kaoping River between the years 2010 and 2011. Salmonella was detected in 31.7% (32/101) and 42.2% (30/71) of the samples from the two rivers, respectively. From these positive samples, 44 Salmonella isolates were obtained from these positive samples and were characterized using serotyping and pulsed-field gel electrophoresis (PFGE) genotyping. The isolates were found with 17 serovars and 32 PFGE patterns. Salmonella enterica Newport, Bareilly, Kedougou, Albany and subspecies IIIb 50:k:z were the five most common serovars in aquatic environmental Salmonella isolates. In addition, of the total clinical samples from Chiayi and Kaohsiung, 33.7% (60/178) Newport serovars were isolated. After conducting categorical analysis, we found that the serovar Newport was not uniformly distributed cross the cities. The serovar Newport was over-represented (p<0.001) among human isolates in Chiayi and Kaohsiung. To investigate the association between Salmonella isolates from aquatic environment and human samples, we compared the environmental PFGE patterns of the test samples with those of 2438 clinical isolates, obtained from 51 hospitals across the country between 2010 and 2011. Of the 32 PFGE genotypes of environmental isolates, 8 genotypes were identical to those of clinical samples. Serovar Newport isolates with PFGE patterns SNX.119 and SNX.183 obtained from Puzih River samples were also identified in human samples at a local hospital. These suggest that there is a link between environmental and human clinical Salmonella. Identification of Salmonella serovars and genotypes present in surface water provides an indication of the specific S. enterica serovars and genotypes present in humans. This is the first study to investigate the Salmonella serovars and genotypes present in aquatic environment and

  16. Trace analysis of total naphthenic acids in aqueous environmental matrices by liquid chromatography/mass spectrometry-quadrupole time of flight mass spectrometry direct injection.

    Science.gov (United States)

    Brunswick, Pamela; Shang, Dayue; van Aggelen, Graham; Hindle, Ralph; Hewitt, L Mark; Frank, Richard A; Haberl, Maxine; Kim, Marcus

    2015-07-31

    A rapid and sensitive liquid chromatography quadrupole time of flight method has been established for the determination of total naphthenic acid concentrations in aqueous samples. This is the first methodology that has been adopted for routine, high resolution, high throughput analysis of total naphthenic acids at trace levels in unprocessed samples. A calibration range from 0.02 to 1.0μgmL(-1) total Merichem naphthenic acids was validated and demonstrated excellent accuracy (97-111% recovery) and precision (1.9% RSD at 0.02μgmL(-1)). Quantitative validation was also demonstrated in a non-commercial oil sands process water (OSPW) acid extractable organics (AEOs) fraction containing a higher percentage of polycarboxylic acid isomers than the Merichem technical mix. The chromatographic method showed good calibration linearity of ≥0.999 RSQ to 0.005μgmL(-1) total naphthenic acids with a precision <3.1% RSD and a calculated detection limit of 0.0004μgmL(-1) employing Merichem technical mix reference material. The method is well suited to monitoring naturally occurring and industrially derived naphthenic acids (and other AEOs) present in surface and ground waters in the vicinity of mining developments. The advantage of the current method is its direct application to unprocessed environmental samples and to examine natural naphthenic acid isomer profiles. It is noted that where the isomer profile of samples differs from that of the reference material, results should be considered semi-quantitative due to the lack of matching isomer content. The fingerprint profile of naphthenic acids is known to be transitory during aging and the present method has the ability to adapt to monitoring of these changes in naphthenic acid content. The method's total ion scan approach allows for data previously collected to be examined retrospectively for specific analyte mass ions of interest. A list of potential naphthenic acid isomers that decrease in response with aging is proposed

  17. Analytical laboratory quality assurance guidance in support of EM environmental sampling and analysis activities

    International Nuclear Information System (INIS)

    1994-05-01

    This document introduces QA guidance pertaining to design and implementation of laboratory procedures and processes for collecting DOE Environmental Restoration and Waste Management (EM) ESAA (environmental sampling and analysis activities) data. It addresses several goals: identifying key laboratory issues and program elements to EM HQ and field office managers; providing non-prescriptive guidance; and introducing environmental data collection program elements for EM-263 assessment documents and programs. The guidance describes the implementation of laboratory QA elements within a functional QA program (development of the QA program and data quality objectives are not covered here)

  18. Dispersive Liquid-Liquid Microextraction Combined with Ultrahigh Performance Liquid Chromatography/Tandem Mass Spectrometry for Determination of Organophosphate Esters in Aqueous Samples

    Directory of Open Access Journals (Sweden)

    Haiying Luo

    2014-01-01

    Full Text Available A new technique was established to identify eight organophosphate esters (OPEs in this work. It utilised dispersive liquid-liquid microextraction in combination with ultrahigh performance liquid chromatography/tandem mass spectrometry. The type and volume of extraction solvents, dispersion agent, and amount of NaCl were optimized. The target analytes were detected in the range of 1.0–200 µg/L with correlation coefficients ranging from 0.9982 to 0.9998, and the detection limits of the analytes were ranged from 0.02 to 0.07 µg/L (S/N=3. The feasibility of this method was demonstrated by identifying OPEs in aqueous samples that exhibited spiked recoveries, which ranged between 48.7% and 58.3% for triethyl phosphate (TEP as well as between 85.9% and 113% for the other OPEs. The precision was ranged from 3.2% to 9.3% (n=6, and the interprecision was ranged from 2.6% to 12.3% (n=5. Only 2 of the 12 selected samples were tested to be positive for OPEs, and the total concentrations of OPEs in them were 1.1 and 1.6 µg/L, respectively. This method was confirmed to be simple, fast, and accurate for identifying OPEs in aqueous samples.

  19. Rapid and automated determination of plutonium and neptunium in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Qiao, J.

    2011-03-15

    This thesis presents improved analytical methods for rapid and automated determination of plutonium and neptunium in environmental samples using sequential injection (SI) based chromatography and inductively coupled plasma mass spectrometry (ICP-MS). The progress of methodology development in this work consists of 5 subjects stated as follows: 1) Development and optimization of an SI-anion exchange chromatographic method for rapid determination of plutonium in environmental samples in combination of inductively coupled plasma mass spectrometry detection (Paper II); (2) Methodology development and optimization for rapid determination of plutonium in environmental samples using SI-extraction chromatography prior to inductively coupled plasma mass spectrometry (Paper III); (3) Development of an SI-chromatographic method for simultaneous determination of plutonium and neptunium in environmental samples (Paper IV); (4) Investigation of the suitability and applicability of 242Pu as a tracer for rapid neptunium determination using anion exchange chromatography in an SI-network coupled with inductively coupled plasma mass spectrometry (Paper V); (5) Exploration of macro-porous anion exchange chromatography for rapid and simultaneous determination of plutonium and neptunium within an SI system (Paper VI). The results demonstrate that the developed methods in this study are reliable and efficient for accurate assays of trace levels of plutonium and neptunium as demanded in different situations including environmental risk monitoring and assessment, emergency preparedness and surveillance of contaminated areas. (Author)

  20. Determination of Sunset Yellow and Tartrazine in Food Samples by Combining Ionic Liquid-Based Aqueous Two-Phase System with High Performance Liquid Chromatography

    Science.gov (United States)

    Sha, Ou; Zhu, Xiashi; Feng, Yanli; Ma, Weixing

    2014-01-01

    We proposed a simple and effective method, by coupling ionic liquid-based aqueous two-phase systems (IL-ATPSs) with high performance liquid chromatography (HPLC), for the analysis of determining tartrazine and sunset yellow in food samples. Under the optimized conditions, IL-ATPSs generated an extraction efficiency of 99% for both analytes, which could then be directly analyzed by HPLC without further treatment. Calibration plots were linear in the range of 0.01–50.0 μg/mL for both Ta and SY. The limits of detection were 5.2 ng/mL for Ta and 6.9 ng/mL for SY. This method proves successful for the separation/analysis of tartrazine and sunset yellow in soft drink sample, candy sample, and instant powder drink and leads to consistent results as obtained from the Chinese national standard method. PMID:25538857

  1. Determination of Sunset Yellow and Tartrazine in Food Samples by Combining Ionic Liquid-Based Aqueous Two-Phase System with High Performance Liquid Chromatography

    Directory of Open Access Journals (Sweden)

    Ou Sha

    2014-01-01

    Full Text Available We proposed a simple and effective method, by coupling ionic liquid-based aqueous two-phase systems (IL-ATPSs with high performance liquid chromatography (HPLC, for the analysis of determining tartrazine and sunset yellow in food samples. Under the optimized conditions, IL-ATPSs generated an extraction efficiency of 99% for both analytes, which could then be directly analyzed by HPLC without further treatment. Calibration plots were linear in the range of 0.01–50.0 μg/mL for both Ta and SY. The limits of detection were 5.2 ng/mL for Ta and 6.9 ng/mL for SY. This method proves successful for the separation/analysis of tartrazine and sunset yellow in soft drink sample, candy sample, and instant powder drink and leads to consistent results as obtained from the Chinese national standard method.

  2. Determination of sunset yellow and tartrazine in food samples by combining ionic liquid-based aqueous two-phase system with high performance liquid chromatography.

    Science.gov (United States)

    Sha, Ou; Zhu, Xiashi; Feng, Yanli; Ma, Weixing

    2014-01-01

    We proposed a simple and effective method, by coupling ionic liquid-based aqueous two-phase systems (IL-ATPSs) with high performance liquid chromatography (HPLC), for the analysis of determining tartrazine and sunset yellow in food samples. Under the optimized conditions, IL-ATPSs generated an extraction efficiency of 99% for both analytes, which could then be directly analyzed by HPLC without further treatment. Calibration plots were linear in the range of 0.01-50.0 μg/mL for both Ta and SY. The limits of detection were 5.2 ng/mL for Ta and 6.9 ng/mL for SY. This method proves successful for the separation/analysis of tartrazine and sunset yellow in soft drink sample, candy sample, and instant powder drink and leads to consistent results as obtained from the Chinese national standard method.

  3. Helium-3 mass spectrometry for low-level tritium analysis of environmental samples

    International Nuclear Information System (INIS)

    Surano, K.A.; Hudson, G.B.; Failor, R.A.; Sims, J.M.; Holland, R.C.; MacLean, S.C.; Garrison, J.C.

    1991-04-01

    Helium-3 ( 3 He) mass spectrometry for the analysis of low-level tritium ( 3 H) concentrations in environmental sample matrices was compared with conventional low-level β-decay counting methods. The mass-spectrometry method compared favorably, equaling or surpassing conventional decay-counting methods with respect to most criteria. Additional research and method refinements may make 3 He mass spectrometry the method of choice for routine, low-level to very-low-level 3 H measurements in a wide variety of environmental samples in the future

  4. Semi-nested polymerase chain reaction for detection of toxigenic Vibrio cholerae from environmental water samples

    OpenAIRE

    Goel, Ajay Kumar; Bhadauria, Shweta; Kumar, Pramod; Kamboj, Dev V.; Singh, Lokendra

    2007-01-01

    A rapid and sensitive direct cell semi-nested PCR assay was developed for the detection of viable toxigenic V. cholerae in environmental water samples. The semi-nested PCR assay amplified cholera toxin (ctxA2B) gene present in the toxigenic V. cholerae. The detection sensitivity of direct cell semi-nested PCR was 2 × 103 CFU of V. cholerae whereas direct cell single-step PCR could detect 2 × 104 CFU of V. cholerae. The performance of the assay was evaluated using environmental water samples a...

  5. Environmental dependence of different colors in the CMASS sample of the SDSS DR9

    OpenAIRE

    Deng, Xin-Fa

    2014-01-01

    In this study, I investigate the environmental dependence of galaxy colors in the CMASS sample of the Sloan Digital Sky Survey Data Release 9 (SDSS DR9). To decrease the radial selection effect, I divide the CMASS sample into subsamples with a redshift binning size of 0.01 and analyze the environmental dependence of the u-r, u-g, g-r, r-i and i-z colors for these subsamples in each redshift bin. Statistical analysis shows that all the five colors weakly correlate with the local environment, w...

  6. The role of NAA in the environmental studies. Quantitative determination of heavy metals pollutant on environmental samples

    International Nuclear Information System (INIS)

    Sutisna; Yusuf, Saeful; Fisli, Adel; Rukihati; Wardhani, Sri; Th Rina M

    2003-01-01

    The neutron activation analysis technique was applied in the elemental analysis of environmental samples to solve an environmental pollution problem. We focused our study in the analysis of heavy metal which has potentially become a pollutant. The environmental samples analyzed were some water, sediment and an air particulate matter. The tap water sample was collected from five samplings points located at region of Serpong and Muria. Meanwhile the river water samples were taken from five samplings points of Ciliwung River. Eight samplings points of Cisadane river estuary located at Tanjung Burung were selected to collect sediment samples. Air particulate samples were collected from Jakarta Metropolitan and Serpong using high volume air sampler. Trace elements analyses of water samples were done using a combination of INAA and pre-concentration stage prior irradiation. All samples were irradiated at GA. Siwabessy reactor located at Serpong using a thermal neutron flux of about 10 12 n.cm -2 .sec -1 . After cooling time, the samples irradiated were counted by a high resolution HPGe detector coupled to a multichannel analyzer. The quantitative analyses have been done using a comparative method to a fresh laboratory standard and we used some standard references materials to validate our analytical result. The obtained result from the tap water analysis show that the elements of As, Cr, Co, Cd, Mn, Sb and Zn could be determine quantitatively and they have a concentration range from about 0.02 μg/L to 103.9 μg/L. The analysis result of Ciliwung river water samples show that elements of Ag, As, Co, Cu, Fe, Hg, Mn, V and Zn are present in the range of 2.4 μg/L to about 1365.8 μg/L. Meanwhile some important elements were obtained in the sediments samples taken from Cisadane River estuary such as Ce (40.4 - 63.6 mg/kg), Co (15.2 - 40.2 mg/kg), Cr (21.6 - 57.8 mg/kg), Eu (1.2 - 1.8 mg/kg), Fe (7.0 - 16.8 mg/kg), Mn (887 - 1810 mg/kg) and V (160 - 558 mg/kg). Finally the

  7. A Needed Paradigm Change for Environmental Soil Sampling at Urban Sites

    Science.gov (United States)

    Clausen, J. L.; Bednar, A. J.

    2015-12-01

    Heterogeneous distribution of solid contaminant residues in surface soils creates an unique challenge for collecting soil samples yielding representative and reproducible results. Research over the past decade involving energetic and metallic residues indicates conventional grab sampling yields unreproducible, biased, results with poor precision non-representative of site conditions. Spatially, grab sampling yields information only about the point sampled. However, risk assessment and remedial decisions are based on contaminant distribution over an area. Multiple grab samples are collected for spatial coverage with the number often based on "expert opinion". Recent research suggests new field sampling and laboratory processing procedures encompassed in the Incremental Sampling Methodology (ISM) and incorporated into United States Environmental Protection (USEPA) Method 8330B for energetics and the update to Method 3050B for metals are necessary to overcome heterogeneity issues. The ISM approach is different from conventional grab sampling due to the focus on a spatially averaged result over a decision unit (DU) obtained by the collection of many increments using a systematic random sampling approach to form a single sample. Total precision error using ISM is typically 100% are observed between field splits and laboratory replicates with conventional grab sampling. Field splitting often employed prior to laboratory sample processing resulted in poor precision and is not recommended. Milling or grinding of soil samples is necessary to reduce the total error of the sample and to obtain acceptable precision, especially in situations where the mean contaminant concentration is expected to be near the action level or other regulatory value.

  8. Determination of 90Sr in environmental samples by microwave assisted digestion - chromatographic separation

    International Nuclear Information System (INIS)

    Torres, J.M.; Llaurado, M.; Rauret, G.

    1998-01-01

    The stages involved in the determination of 90 Sr in environmental samples are: sample attack, radiochemical separation (of both 90 Sr and its progeny 90 Y) and measurement. For the determination of 90 Sr, the introduction of microwave-assisted digestion methods has improved acid attack by drastically decreasing both digestion time and the volume of acidic reagents. Recent studies describe many applications of microwave-assisted methods for the determination of inorganic and organometallic compounds in several matrices. We have recently studied the microwave-assisted digestion of soils for the 90 Sr determination. The presented work extends the application of microwaves for the 90 Sr determination to other environmental samples such as sediments, vegetation and milk. An open-focused microwave system, which accepts large samples intakes usually required for radioanalytical chemistry due to the low level content of radionuclides in environmental samples, was used. This system can handle up to 10 g of sample intake which, in many cases, is enough to have acceptable limits of detection. Different digestion procedures are optimised for each matrix studied, paying special attention to the microwave power, the time of digestion and the volume of acidic reagents. Once the sample is in solution a new separation procedure using a specific resin -Sr.Spec- is applied and the measurement is performed by liquid scintillation. The results obtained are compared with a previously optimised method based on liquid-liquid extraction of 90 Y and Cerenkov radiation measurement

  9. Measurement of I-129 in environmental samples by ICP-CRI-QMS. Possibilities and limitations

    Energy Technology Data Exchange (ETDEWEB)

    Li, K.; Vogel, E.; Kraehenbuehl, U. [Dept. of Chemistry and Biochemistry, Univ. of Bern (Switzerland)

    2009-07-01

    {sup 129}I is preconcentrated from environmental samples and its accessibility is addressed for inductively coupled plasma quadrupole mass spectrometer with collision/reaction interface (ICP-CRI-QMS). By applying oxygen as CRI gas through skimmer cone, the signal of the interfering {sup 129}Xe from the impurity of plasma gas can be eliminated while the formation of {sup 127}I{sup 1}H{sup 1}H{sup +} can be partially removed. The improved ICP-QMS can be employed for investigation of {sup 129}I in environmental samples with a {sup 129}I/{sup 127}I ratio down to 10{sup -7}. The detection capability was demonstrated by measuring {sup 129}I in seaweed samples collected around the nuclear fuel reprocessing plant at La Hague. The abundant {sup 127}I in the sample matrix causes a serious problem and degrades the detection capability of the instrument when the concentration of {sup 127}I is larger than 10{sup 5} ng/g. Even combined with a sufficient pre-concentration procedure, ICP-QMS is not considered as a suitable technique for the analysis of {sup 129}I in uncontaminated environmental samples with {sup 129}I/{sup 127}I ratio of less than 10{sup -7}. Results are presented for seaweed samples collected around La Hague. In addition, time dependant I concentrations and ratios are given for colloids and water sampled from Lake Thun. (orig.)

  10. Study of Efficiency Calibrations of HPGe Detectors for Radioactivity Measurements of Environmental Samples

    International Nuclear Information System (INIS)

    Harb, S.; Salahel Din, K.; Abbady, A.

    2009-01-01

    In this paper, we describe a method of calibrating of efficiency of a HPGe gamma-ray spectrometry of bulk environmental samples (Tea, crops, water, and soil) is a significant part of the environmental radioactivity measurements. Here we will discuss the full energy peak efficiency (FEPE) of three HPGe detectors it as a consequence, it is essential that the efficiency is determined for each set-up employed. Besides to take full advantage at gamma-ray spectrometry, a set of efficiency at several energies which covers the wide the range in energy, the large the number of radionuclides whose concentration can be determined to measure the main natural gamma-ray emitters, the efficiency should be known at least from 46.54 keV ( 210 Pb) to 1836 keV ( 88 Y). Radioactive sources were prepared from two different standards, a first mixed standard QC Y 40 containing 210 Pb, 241 Am, 109 Cd, and Co 57 , and the second QC Y 48 containing 241 Am, 109 Cd, 57 Co, 139 Ce, 113 Sn, 85 Sr, 137 Cs, 88 Y, and 60 Co is necessary in order to calculate the activity of the different radionuclides contained in a sample. In this work, we will study the efficiency calibration as a function of different parameters as:- Energy of gamma ray from 46.54 keV ( 210 Pb) to 1836 keV ( 88 Y), three different detectors A, B, and C, geometry of containers (point source, marinelli beaker, and cylindrical bottle 1 L), height of standard soil samples in bottle 250 ml, and density of standard environmental samples. These standard environmental sample must be measured before added standard solution because we will use the same environmental samples in order to consider the self absorption especially and composition in the case of volume samples.

  11. Determination of phenoxy acid herbicides frm aqueous samples by improved clean-up on polymeric precolumns at high pH.

    NARCIS (Netherlands)

    Geerdink, R.B.; van Tol-Wildenburg, S.; Niessen, W.M.A.; Brinkman, U.A.T.

    1997-01-01

    An improved procedure for the determination of phenoxy acid herbicides in environmental water samples is reported. The procedure consists in solid-phase extraction (SPE) of 60 ml water samples on a polymeric pre-column at pH 2.8, a clean-up step at high pH and subsequent desorption and ion-pair LC

  12. Recovery and identification of Pseudo-nitzschia (Bacillariophyceae) frustules from natural samples acquired using the environmental sample processor.

    Science.gov (United States)

    Bowers, Holly A; Marin, Roman; Birch, James M; Scholin, Christopher A; Doucette, Gregory J

    2016-02-01

    Many species within the diatom genus Pseudo-nitzschia are difficult to distinguish without applying molecular analytical or microscopy-based methods. DNA, antibody and lectin probes have previously been used to provide rapid and specific detection of species and strains in complex field assemblages. Recently, however, well-documented cryptic genetic diversity within the group has confounded results of DNA probe tests in particular. Moreover, the number of species descriptions within the genus continues to increase, as do insights into toxin production by both new and previously described species. Therefore, a combination of classical morphological techniques and modern molecular methodologies is needed to resolve ecophysiological traits of Pseudo-nitzschia species. Here, we present an approach to recover and identify frustules from sample collection filters used for toxin analysis onboard the Environmental Sample Processor (ESP), an in situ sample collection and analytical platform. This approach provides a new and powerful tool for correlating species presence with toxin detected remotely and in situ by the ESP, and has the potential to be applied broadly to other sampling configurations. This new technique will contribute to a better understanding of naturally occurring Pseudo-nitzschia community structure with respect to observed domoic acid outbreaks. © 2015 Phycological Society of America.

  13. Prospects for the introduction of Wide Area Monitoring Using Environmental Sampling

    International Nuclear Information System (INIS)

    Wogman, N.A.

    2013-01-01

    Nuclear proliferation signatures released to the environment must be collected and distinguished from primordial and man-made backgrounds in soils, sediments, air, and surface and underground water. The delay time between the nuclear proliferation emissions and the date of the Wide-Area Environmental Sampling (WAES) analysis will determine which radionuclides would be analyzed based upon their half-lives. Various sampling and analysis technologies have been considered here for application to a WAES. Sampling procedures and equipment discussed are aimed at aquatic, airborne particulate, gas, vegetation, sediment and/or soil, and fauna media. Specific procedures must be selected based upon the application scenario; for example, sampling in the northern latitudes under freezing conditions, sampling at the equator under tropical rain-forest conditions, sampling in the mid-latitudes under desert conditions, and sampling in the marine environment require different equipment and procedures. The paper is followed by the slides of the presentation

  14. Determination of short-lived trace elements in environmental samples by neutron activation analysis

    International Nuclear Information System (INIS)

    Wardani, S.; Sihombing, E.; Hamzah, A.; Rochidi; Hery, P.S.; Hartaman, S.; Iman, J.

    1998-01-01

    Concentration of a short-lived trace elements in environmental samples were determined by neutron activation analysis, a counting loss often occur due to the high counting rate. A Pile-Up Rejecter (PUR) electric circuit was installed in counting a short-lived trace elements by a γ-ray spectrometer in order to correct a counting loss. The samples were irradiated for 30∼60 seconds at neutron flux of 3.5 x 10 12 n.cm -2 .s -1 , then the samples cooled for 120 second and counted for 180 second using this system. The nuclides concentration in the varieties environmental samples have a difference analysis result, was more accurate and precise, which the measured result would be 30 % more higher by PUR system than the result would be counted using a conventional γ-ray spectrometry method

  15. Green Aspects of Techniques for the Determination of Currently Used Pesticides in Environmental Samples

    Science.gov (United States)

    Stocka, Jolanta; Tankiewicz, Maciej; Biziuk, Marek; Namieśnik, Jacek

    2011-01-01

    Pesticides are among the most dangerous environmental pollutants because of their stability, mobility and long-term effects on living organisms. Their presence in the environment is a particular danger. It is therefore crucial to monitor pesticide residues using all available analytical methods. The analysis of environmental samples for the presence of pesticides is very difficult: the processes involved in sample preparation are labor-intensive and time-consuming. To date, it has been standard practice to use large quantities of organic solvents in the sample preparation process; but as these solvents are themselves hazardous, solvent-less and solvent-minimized techniques are becoming popular. The application of Green Chemistry principles to sample preparation is primarily leading to the miniaturization of procedures and the use of solvent-less techniques, and these are discussed in the paper. PMID:22174632

  16. The determination of arsenic, selenium, antimony, and tin in complex environmental samples by hydride generation AAS

    International Nuclear Information System (INIS)

    Johnson, D.; Beach, C.

    1990-01-01

    Hydride generation techniques are used routinely for the determination of As, Se, Sb and Sn in water samples. Advantages include high sensitivity, simplicity, and relative freedom from interferences. Continuous-flow designs greatly reduce analysis time as well as improve precision and allow for automation. However the accurate analysis of more complex environmental samples such as industrial sludges, soil samples, river sediments, and fly ash remains difficult. Numerous contributing factors influence the accuracy of the hydride technique. Sample digestion methods and sample preparation procedures are of critical importance. The digestion must adequately solubilize the elements of interest without loss by volatilization. Sample preparation procedures that guarantee the proper analyte oxidation state and eliminate the nitric acid and inter-element interferences are needed. In this study, difficult environmental samples were analyzed for As, Se, Sb, and Sn by continuous flow hydride generation. Sample preparation methods were optimized to eliminate interferences. The results of spike recovery studies will be presented. Data from the analysis of the same samples by graphite furnace AAS will be presented for comparison of accuracy, precision, and analysis time

  17. ANALYSIS OF SULFONATES IN AQUEOUS SAMPLES BY ION-PAIR LC/ESI-MS/MS WITH IN-SOURCE CID FOR ADDUCT PEAK ELIMINATION

    Energy Technology Data Exchange (ETDEWEB)

    OUYANG,S.; VAIRAVAMURTHY,M.A.

    1999-06-13

    Determination of low-molecular-weight organic sulfonates (e.g. taurine and cysteic acid) in aqueous solutions is important in many applications of biological, environmental and pharmaceutical sciences. These compounds are difficult to be determined by commonly used reversed-phase liquid chromatographic separation combined with UV-Visible detection because of their high solubility and the lack chromophoric moieties. Here the authors report a method combining ion-pair liquid chromatography and electrospray ionization tandem mass spectrometry (IPLC/ESI-MS/MS)for determining sulfonates. The ability of low-molecular-weight sulfonates to form ion-pairs with quaternary ammonium cations in aqueous solutions allowed LC separation with a C{sub 18} column. Detection of the sulfonates was accomplished with ESI-MS that lends a universal mode of mass detection for polar, water soluble compounds. An in-source collision induced dissociation (CID) was applied to eliminate the adduct peaks in mass spectra. Characteristic marker ions showed in the second stage mass spectra lent a method for identifying sulfonates.

  18. Master schedule for CY-1984 Hanford environmental surveillance routine sampling program

    International Nuclear Information System (INIS)

    Blumer, P.J.; Price, K.R.; Eddy, P.A.; Carlile, J.M.V.

    1983-12-01

    This report provides the current schedule of data collection for the routine Hanford environmental surveillance and ground-water Monitoring Programs at the Hanford Site. The purpose is to evaluate and report the levels of radioactive and nonradioactive pollutants in the Hanford environs. The routine sampling schedule provided herein does not include samples that are planned to be collected during FY-1984 in support of special studies, special contractor support programs, or for quality control purposes

  19. Determination of artificial and natural radionuclides and others trace elements in environmental samples form Antarctica

    International Nuclear Information System (INIS)

    Schuch, L.A.; Godoy, J.M.; Nordemann, D.J.R.

    1994-01-01

    The results of the radioactive elements concentrations, determined by gamma spectrometry and the others trace elements determined by neutron activation analysis of several environmental samples (soils, marine sediments, algae mosses and lichens) in Comandante Ferraz Antartica Station are presented. The high concentrations of Cs-137 were found in lichens and mosses samples and the soils and sediments showed concentrations of natural radionuclides. (C.G.C.). 8 refs, 1 fig, 3 tabs

  20. Determination of carbon-14 environmental samples by mixing 14CO2 with a liquid scintillator

    International Nuclear Information System (INIS)

    Garcia Sanz, M.R.; Gomez, V.; Heras, M.C.; Beltran, M.A.

    1990-01-01

    A method for the determination of Carbon-14 ( 14 CO 2 ) in environmental samples has been developed. The method use the direct absorption of the carbon dioxide into Carbosorb, followed with incorporation of the mixture (Carbosorb-CO 2 ) to the liquid scintillator. The results obtained to apply this method and the benzene synthesis, usual in our laboratory, are discused and compared. The method of collection of atmospheric samples is also described. (Author)

  1. Determination of Carbon-14 in environmental samples by mixing 14CO2 with a liquid scintillator

    International Nuclear Information System (INIS)

    Garcia, M. R.; Gomez, V.; Heras, M. C.; Beltran, M. A.

    1990-01-01

    A method for the determination of Carbon-14 (14CO2) in environmental samples has been developed. The method use the direct absorption of the carbon dioxide into Carbosorb, followed with incorporation of the mixture (Carbosorb-CO2) to the liquid scintillator. The results obtained to apply this method and the benzene synthesis, usual in our laboratory, are discussed and compared. The method of collection of atmospheric samples is also described. (Author) 10 refs

  2. Method for the concentration and separation of actinides from biological and environmental samples

    Science.gov (United States)

    Horwitz, E.P.; Dietz, M.L.

    1989-05-30

    A method and apparatus for the quantitative recover of actinide values from biological and environmental sample by passing appropriately prepared samples in a mineral acid solution through a separation column of a dialkyl(phenyl)-N,N-dialylcarbamoylmethylphosphine oxide dissolved in tri-n-butyl phosphate on an inert substrate which selectively extracts the actinide values. The actinide values can be eluted either as a group or individually and their presence quantitatively detected by alpha counting. 3 figs.

  3. Systematic review and consensus guidelines for environmental sampling of Burkholderia pseudomallei.

    Science.gov (United States)

    Limmathurotsakul, Direk; Dance, David A B; Wuthiekanun, Vanaporn; Kaestli, Mirjam; Mayo, Mark; Warner, Jeffrey; Wagner, David M; Tuanyok, Apichai; Wertheim, Heiman; Yoke Cheng, Tan; Mukhopadhyay, Chiranjay; Puthucheary, Savithiri; Day, Nicholas P J; Steinmetz, Ivo; Currie, Bart J; Peacock, Sharon J

    2013-01-01

    Burkholderia pseudomallei, a Tier 1 Select Agent and the cause of melioidosis, is a Gram-negative bacillus present in the environment in many tropical countries. Defining the global pattern of B. pseudomallei distribution underpins efforts to prevent infection, and is dependent upon robust environmental sampling methodology. Our objective was to review the literature on the detection of environmental B. pseudomallei, update the risk map for melioidosis, and propose international consensus guidelines for soil sampling. An international working party (Detection of Environmental Burkholderia pseudomallei Working Party (DEBWorP)) was formed during the VIth World Melioidosis Congress in 2010. PubMed (January 1912 to December 2011) was searched using the following MeSH terms: pseudomallei or melioidosis. Bibliographies were hand-searched for secondary references. The reported geographical distribution of B. pseudomallei in the environment was mapped and categorized as definite, probable, or possible. The methodology used for detecting environmental B. pseudomallei was extracted and collated. We found that global coverage was patchy, with a lack of studies in many areas where melioidosis is suspected to occur. The sampling strategies and bacterial identification methods used were highly variable, and not all were robust. We developed consensus guidelines with the goals of reducing the probability of false-negative results, and the provision of affordable and 'low-tech' methodology that is applicable in both developed and developing countries. The proposed consensus guidelines provide the basis for the development of an accurate and comprehensive global map of environmental B. pseudomallei.

  4. Systematic review and consensus guidelines for environmental sampling of Burkholderia pseudomallei.

    Directory of Open Access Journals (Sweden)

    Direk Limmathurotsakul

    Full Text Available Burkholderia pseudomallei, a Tier 1 Select Agent and the cause of melioidosis, is a Gram-negative bacillus present in the environment in many tropical countries. Defining the global pattern of B. pseudomallei distribution underpins efforts to prevent infection, and is dependent upon robust environmental sampling methodology. Our objective was to review the literature on the detection of environmental B. pseudomallei, update the risk map for melioidosis, and propose international consensus guidelines for soil sampling.An international working party (Detection of Environmental Burkholderia pseudomallei Working Party (DEBWorP was formed during the VIth World Melioidosis Congress in 2010. PubMed (January 1912 to December 2011 was searched using the following MeSH terms: pseudomallei or melioidosis. Bibliographies were hand-searched for secondary references. The reported geographical distribution of B. pseudomallei in the environment was mapped and categorized as definite, probable, or possible. The methodology used for detecting environmental B. pseudomallei was extracted and collated. We found that global coverage was patchy, with a lack of studies in many areas where melioidosis is suspected to occur. The sampling strategies and bacterial identification methods used were highly variable, and not all were robust. We developed consensus guidelines with the goals of reducing the probability of false-negative results, and the provision of affordable and 'low-tech' methodology that is applicable in both developed and developing countries.The proposed consensus guidelines provide the basis for the development of an accurate and comprehensive global map of environmental B. pseudomallei.

  5. Analytical Methodology for the Determination of Radium Isotopes in Environmental Samples

    International Nuclear Information System (INIS)

    2010-01-01

    Reliable, comparable and 'fit for purpose' results are an essential requirement for any decision based on analytical measurements. For the analyst, the availability of tested and validated analytical procedures is an extremely important tool for production of such analytical measurements. For maximum utility, such procedures should be comprehensive, clearly formulated, and readily available to both the analyst and the customer for reference. Since 2004, the environment programme of the IAEA has included activities aimed at the development of a set of procedures for the determination of radionuclides in terrestrial environmental samples. Measurements of radium isotopes are important for radiological and environmental protection, geochemical and geochronological investigations, hydrology, etc. The suite of isotopes creates and stimulates continuing interest in the development of new methods for determination of radium in various media. In this publication, the four most routinely used analytical methods for radium determination in biological and environmental samples, i.e. alpha spectrometry, gamma spectrometry, liquid scintillation spectrometry and mass spectrometry, are reviewed

  6. Self-absorption corrections for gamma ray spectral measurements of 210Pb in environmental samples

    International Nuclear Information System (INIS)

    Miller, K.M.

    1987-01-01

    Theoretical considerations and experimental data are used to demonstrate the basic behaviour of the self-absorption effect of a sample matrix in gamma ray spectrometry, particularly as it relates to the analysis of 210 Pb in environmental media. The results indicate that it may not be appropriate to apply the commonly used self-absorption function in all cases. (orig.)

  7. Controlled dehydration of a biological sample using an alternative form of environmental SEM

    Czech Academy of Sciences Publication Activity Database

    Neděla, Vilém

    2010-01-01

    Roč. 237, č. 1 (2010), s. 7-11 ISSN 0022-2720 Institutional research plan: CEZ:AV0Z20650511 Keywords : biological sample * dehydration * environmental SEM * AQUASEM II * hydration system Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 1.872, year: 2010

  8. Reproducibility of measurement of the environmental carbon-14 samples prepared by the gel suspension method

    International Nuclear Information System (INIS)

    Ohura, Hirotaka; Wakabayashi, Genichiro; Nakamura, Kouji; Okai, Tomio; Matoba, Masaru; Kakiuchi, Hideki; Momoshima, Noriyuki; Kawamura, Hidehisa.

    1997-01-01

    Simple liquid scintillation counting technique for the assay of 14 C in the environment was developed. This technique was done by using gel suspension method, in which sample preparation is very simple and requires no special equipments. The reproducibility of this technique was considered and it was shown that the gel suspension method had enough reproducibility to monitor the environmental 14 C. (author)

  9. Fractionation of plutonium in environmental and bio-shielding concrete samples using dynamic sequential extraction

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin

    2010-01-01

    Fractionation of plutonium isotopes (238Pu, 239,240Pu) in environmental samples (i.e. soil and sediment) and bio-shielding concrete from decommissioning of nuclear reactor were carried out by dynamic sequential extraction using an on-line sequential injection (SI) system combined with a specially...... to the treatment and disposal of nuclear waste from decommissioning....

  10. Computer system for environmental sample analysis and data storage and analysis

    International Nuclear Information System (INIS)

    Brauer, F.P.; Fager, J.E.

    1976-01-01

    A mini-computer based environmental sample analysis and data storage system has been developed. The system is used for analytical data acquisition, computation, storage of analytical results, and tabulation of selected or derived results for data analysis, interpretation and reporting. This paper discussed the structure, performance and applications of the system

  11. Repurposing environmental DNA samples: Detecting the western pearlshell (Margaritifera falcata) as a proof of concept

    Science.gov (United States)

    Joseph C. Dysthe; Torrey Rodgers; Thomas W. Franklin; Kellie J. Carim; Michael K. Young; Kevin S. McKelvey; Karen E. Mock; Michael K. Schwartz

    2018-01-01

    Information on the distribution of multiple species in a common landscape is fundamental to effective conservation and management. However, distribution data are expensive to obtain and often limited to high-profile species in a system. A recently developed technique, environmental DNA (eDNA) sampling, has been shown to be more sensitive than traditional detection...

  12. Metallic speciation in environmental samples. La especiacion metalica en muestras medioambientales

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez Uria, J.E.

    1994-01-01

    A review about chemical speciation in environmental samples was developed. Starting from definition of speciation, characteristic techniques and squemes for speciation more adequate for the characterization of the several organic/inorganic metal-species was considered. Finally, the possible future tendences of speciation techniques was also considered. (Author) 27 refs.

  13. Reliable determination of 237Np in environmental solid samples using 242Pu as a potential tracer

    DEFF Research Database (Denmark)

    Qiao, Jixin; Hou, Xiaolin; Roos, Per

    2011-01-01

    onto various AG 1-type anion exchangers; suitability of 242Pu as a tracer for 237Np determination in environmental solid samples; and long-term chemical stability of tetravalent Np. Experimental results revealed that the degree of resin cross-linking has a significant influence on the separation...

  14. Electrodeposition as an alternate method for preparation of environmental samples for iodide by AMS

    International Nuclear Information System (INIS)

    Adamic, M.L.; Lister, T.E.; Dufek, E.J.; Jenson, D.D.; Olson, J.E.; Vockenhuber, C.; Watrous, M.G.

    2015-01-01

    This paper presents an evaluation of an alternate method for preparing environmental samples for 129 I analysis by accelerator mass spectrometry (AMS) at Idaho National Laboratory. The optimal sample preparation method is characterized by ease of preparation, capability of processing very small quantities of iodide, and ease of loading into a cathode. Electrodeposition of iodide on a silver wire was evaluated using these criteria. This study indicates that the electrochemically-formed silver iodide deposits produce ion currents similar to those from precipitated silver iodide for the same sample mass. Precipitated silver iodide samples are usually mixed with niobium or silver powder prior to loading in a cathode. Using electrodeposition, the silver is already mixed with the sample and can simply be picked up with tweezers, placed in the sample die, and pressed into a cathode. The major advantage of this method is that the silver wire/electrodeposited silver iodide is much easier to load into a cathode.

  15. Electrodeposition as an alternate method for preparation of environmental samples for iodide by AMS

    Energy Technology Data Exchange (ETDEWEB)

    Adamic, M.L., E-mail: Mary.Adamic@inl.gov [Idaho National Laboratory, P.O. Box 1625, Idaho Falls, ID 83402 (United States); Lister, T.E.; Dufek, E.J.; Jenson, D.D.; Olson, J.E. [Idaho National Laboratory, P.O. Box 1625, Idaho Falls, ID 83402 (United States); Vockenhuber, C. [Laboratory of Ion Beam Physics, ETH Zurich, Otto-Stern-Weg 5, 8093 Zurich (Switzerland); Watrous, M.G. [Idaho National Laboratory, P.O. Box 1625, Idaho Falls, ID 83402 (United States)

    2015-10-15

    This paper presents an evaluation of an alternate method for preparing environmental samples for {sup 129}I analysis by accelerator mass spectrometry (AMS) at Idaho National Laboratory. The optimal sample preparation method is characterized by ease of preparation, capability of processing very small quantities of iodide, and ease of loading into a cathode. Electrodeposition of iodide on a silver wire was evaluated using these criteria. This study indicates that the electrochemically-formed silver iodide deposits produce ion currents similar to those from precipitated silver iodide for the same sample mass. Precipitated silver iodide samples are usually mixed with niobium or silver powder prior to loading in a cathode. Using electrodeposition, the silver is already mixed with the sample and can simply be picked up with tweezers, placed in the sample die, and pressed into a cathode. The major advantage of this method is that the silver wire/electrodeposited silver iodide is much easier to load into a cathode.

  16. Chitosan-coated octadecyl-functionalized magnetite nanoparticles: preparation and application in extraction of trace pollutants from environmental water samples.

    Science.gov (United States)

    Zhang, Xiaole; Niu, Hongyun; Pan, Yuanyuan; Shi, Yali; Cai, Yaqi

    2010-03-15

    In the present study, chitosan-coated octadecyl-functionalized magnetite nanoparticles (Fe(3)O(4)-C(18)-chitosan MNPs) are synthesized and used as an adsorbent to extract trace analytes from environmental water samples. The magnetic nanoparticles, 20 nm in diameter, are of uniform size and have a high magnetic saturation value of 52 emu g(-1), which endue the adsorbent with a large surface area and convenience of isolation. The anionic pollutants, perfluorinated compounds (PFCs), are trapped by the octadecyl group of the interior hydrophobic layer. The positively charged chitosan polymer coating also contributes to PFC enrichment. At the same time, the coating improves the dispersibility of MNPs in aqueous solution and enhances the anti-interference ability of the adsorbent to natural organic macromolecules in complex samples by size exclusion or electrostatic repulsion. A liquid chromatography-tandem mass spectrometry system is employed in the determination of PFCs after preconcentration with the MNP adsorbent. The predominant factors affecting preconcentration are investigated and optimized. Under the selected conditions, concentration factors of 1000 are achieved by extracting the analytes from 500 mL of several environmental water samples and concentrating the eluants to 0.5 mL with a nitrogen flow. The method detection limits obtained for perfluorooctanoic acid (PFOA), perfluorooctanesulfonic acid (PFOS), perfluorononanoic acid (PFNA), perluorodecanoic acid (PFDA), perfluoroundecanoic acid (PFUnDA), perfluorododecanoic acid (PFDoDA), and perfluorotetradecanoic acid (PFTA) in Gaobeidian wastewater are 0.24, 0.093, 0.24, 0.14, 0.075, 0.24, and 0.17 ng L(-1), respectively. Recoveries of PFOA, PFOS, PFNA, PFDA, PFUnDA, PFDoDA, and PFTA are in the ranges of 88-108%, 63-112%, 79-109%, 56-107%, 66-106%, 56-106%, and 66-103% for four spiked water samples with low relative standard deviation (2-8%), which indicates good method precision. The advantages of this novel

  17. Monitoring Pb in Aqueous Samples by Using Low Density Solvent on Air-Assisted Dispersive Liquid-Liquid Microextraction Coupled with UV-Vis Spectrophotometry.

    Science.gov (United States)

    Nejad, Mina Ghasemi; Faraji, Hakim; Moghimi, Ali

    2017-04-01

    In this study, AA-DLLME combined with UV-Vis spectrophotometry was developed for pre-concentration, microextraction and determination of lead in aqueous samples. Optimization of the independent variables was carried out according to chemometric methods in three steps. According to the screening and optimization study, 86 μL of 1-undecanol (extracting solvent), 12 times syringe pumps, pH 2.0, 0.00% of salt and 0.1% DDTP (chelating agent) were chosen as the optimum independent variables for microextraction and determination of lead. Under the optimized conditions, R = 0.9994, and linearity range was 0.01-100 µg mL -1 . LOD and LOQ were 3.4 and 11.6 ng mL -1 , respectively. The method was applied for analysis of real water samples, such as tap, mineral, river and waste water.

  18. 135Cs/137Cs isotopic composition of environmental samples across Europe: Environmental transport and source term emission applications

    International Nuclear Information System (INIS)

    Snow, Mathew S.; Snyder, Darin C.

    2016-01-01

    135 Cs/ 137 Cs isotopic analyses represent an important tool for studying the fate and transport of radiocesium in the environment; in this work the 135 Cs/ 137 Cs isotopic composition in environmental samples taken from across Europe is reported. Surface soil and vegetation samples from western Russia, Ukraine, Austria, and Hungary show consistent aged thermal fission product 135 Cs/ 137 Cs isotope ratios of 0.58 ± 0.01 (age corrected to 1/1/15), with the exception of one sample of soil-moss from Hungary which shows an elevated 135 Cs/ 137 Cs ratio of 1.78 ± 0.12. With the exception of the outlier sample from Hungary, surface soil/vegetation data are in quantitative agreement with values previously reported for soils within the Chernobyl exclusion zone, suggesting that radiocesium at these locations is primarily composed of homogenous airborne deposition from Chernobyl. Seawater samples taken from the Irish Sea show 135 Cs/ 137 Cs isotope ratios of 1.22 ± 0.11 (age corrected to 1/1/15), suggesting aged thermal fission product Cs discharged from Sellafield. The differences in 135 Cs/ 137 Cs isotope ratios between Sellafield, Chernobyl, and global nuclear weapons testing fallout indicate that 135 Cs/ 137 Cs isotope ratios can be utilized to discriminate between and track radiocesium transport from different nuclear production source terms, including major emission sources in Europe. - Highlights: • 135 Cs/ 137 Cs useful for tracking anthropogenic environmental radiocesium releases. • European surface soils/vegetation have uniform ratio consistent with Chernobyl. • 135 Cs/ 137 Cs in Irish sea represents thermal fission ratio distinct from Chernobyl. • Can distinguish between major source terms in Europe based on 135 Cs/ 137 Cs.

  19. Quantitative Digital Autoradiography for Environmental Swipe Sample Prioritization: System design, Characterization, and Initial Measurements

    Energy Technology Data Exchange (ETDEWEB)

    McDonald, Benjamin S.; Zalavadia, Mital A.; Miller, Brian W.; Bliss, Mary; Olsen, Khris B.; Kasparek, Dustin M.; Clarke, Ardelia M.

    2017-07-17

    Environmental sampling and sample analyses by the International Atomic Energy Agency’s (IAEA) Network of Analytical Laboratories (NWAL) is a critical technical tool used to detect facility misuse under a Comprehensive Safeguards Agreement and to verify the absence of undeclared nuclear material activities under an Additional Protocol. Currently all environmental swipe samples (ESS) are screened using gamma spectrometry and x-ray fluorescence to estimate the amount of U and/or Pu in the ESS, to guide further analysis, and to assist in the shipment of ESS to the NWAL. Quantitative Digital Autoradiography for Environmental Samples (QDARES) is being developed to complement existing techniques through the use of a portable, real-time, high-spatial-resolution camera called the Ionizing-radiation Quantum Imaging Detector (iQID). The iQID constructs a spatial map of radionuclides within a sample or surface in real-time as charged particles (betas) and photons (gamma/x-rays) are detected and localized on an event-by-event basis. Knowledge of the location and nature of radioactive hot spots on the ESS could provide information for subsequent laboratory analysis. As a nondestructive technique, QDARES does not compromise the ESS chain of custody or subsequent laboratory analysis. In this paper we will present the system design and construction, characterization measurements with calibration sources, and initial measurements of ESS.

  20. Estimation of octanol/water partition coefficient and aqueous solubility of environmental chemicals using molecular fingerprints and machine learning methods

    Science.gov (United States)

    Octanol/water partition coefficient (logP) and aqueous solubility (logS) are two important parameters in pharmacology and toxicology studies, and experimental measurements are usually time-consuming and expensive. In the present research, novel methods are presented for the estim...

  1. A micro-fluidic sub-microliter sample introduction system for direct analysis of Chinese rice wine by inductively coupled plasma mass spectrometry using external aqueous calibration

    Science.gov (United States)

    Cheng, Heyong; Liu, Jinhua; Xu, Zigang; Yin, Xuefeng

    2012-07-01

    A microfluidic sub-microliter sample introducing system was developed for direct analysis of Chinese rice wine by inductively coupled plasma mass spectrometry (ICP-MS). It consisted of a microfluidic chip integrating variable-volume sampling channels (0.1-0.8 μL), an eight-way multi-functional valve used in flow injection analysis (FIA), a syringe pump and a peristaltic pump of the Ar ICP-MS instrument. Three solutions, i.e., 15, 40 and 100 g L- 1 glucose in 20% ethanol were used to simulate Chinese rice wine of the dry type, the semidry type and the semisweet type, each. The effects of their volume introduced into ICP-MS on the plasma stability and ICP-MS intensities were studied. The experimental results showed that neither alteration of plasma stability nor carbon deposition was observed when the sampling volume of 20% ethanol containing 100 g L- 1 glucose was downscaled to 0.8 μL. Further reducing the sampling volume to 0.4 μL, no significant difference between the intensities of multi-element standard prepared in three simulated Chinese rice wine matrices and those in aqueous solution was observed. It indicated no negative effect of Chinese rice wine matrix on the ICP-MS intensities. A sampling volume of 0.4 μL was considered to be a good compromise between sensitivity and matrix effect. The flow rate of the carrier was chosen as 20 μL min- 1 for obtaining peaks with the highest peak height within the shortest time. Based on these observations, a microflow injection (μFI) method for the direct determination of cadmium and lead in Chinese rice wine by ICP-MS using an external aqueous calibration was developed. The sample throughput was 45 h- 1 with the detection limit of 19.8 and 10.4 ng L- 1 for Cd and Pb, respectively. The contents of Cd and Pb in 10 Chinese rice wine samples were measured. The results agreed well with those determined by ICP-MS with the conventional sampling system after microwave assisted digestion. The recoveries of three Chinese

  2. Somatic Coliphage Profiles of Produce and Environmental Samples from Farms in Northern México.

    Science.gov (United States)

    Bartz, Faith E; Hodge, Domonique Watson; Heredia, Norma; de Aceituno, Anna Fabiszewski; Solís, Luisa; Jaykus, Lee-Ann; Garcia, Santos; Leon, Juan S

    2016-09-01

    Somatic coliphages were quantified in 459 produce and environmental samples from 11 farms in Northern Mexico to compare amounts of somatic coliphages among different types of fresh produce and environmental samples across the production steps on farms. Rinsates from cantaloupe melons, jalapeño peppers, tomatoes, and the hands of workers, soil, and water were collected during 2011-2012 at four successive steps on each farm, from the field before harvest through the packing facility, and assayed by FastPhage MPN Quanti-tray method. Cantaloupe farm samples contained more coliphages than jalapeño or tomato (p range virus contamination and improve food safety during fruit and vegetable production.

  3. Study of the scattering of the light in aqueous samples collagen in the presence of nanoparticles and curcuma pigment

    Science.gov (United States)

    Silva, F. M. L.; Alencar, L. D. S.; Bernardi, M. I. B.; Lima, F. W. S.; Melo, C. A. S.

    2015-06-01

    In this work we investigate the scattering of light in means turbid in the presence or not of pigment and nanoparticles. For this we initially using a sample of collagen from means turbid with and without the presence of curcuma pigments and nanoparticles. Our results show that the light scattering is more intense in the samples with nanoparticles and curcuma pigment.

  4. A Portable Immunoassay Platform for Multiplexed Detection of Biotoxins in Clinical and Environmental Samples

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Chung-Yan [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Piccini, Matthew Ernest [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Cepheid, Sunnyvale, CA (United States); Schaff, Ulrich Y. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Sandstone Diagnostics, Livermore, CA (United States); Stanker, Larry H. [US Dept. of Agriculture, Albany, CA (United States). Western Regional Research Center, Foodborne Contaminants Research Unit; Cheng, Luisa W. [US Dept. of Agriculture, Albany, CA (United States). Western Regional Research Center, Foodborne Contaminants Research Unit; Ravichandran, Easwaran [Univ. of Massachusetts, Dartmouth, MA (United States); Singh, Bal-Ram [Univ. of Massachusetts, Dartmouth, MA (United States); Sommer, Greg J. [Sandia National Lab. (SNL-CA), Livermore, CA (United States); Sandstone Diagnostics, Livermore, CA (United States); Singh, Anup K. [Sandia National Lab. (SNL-CA), Livermore, CA (United States)

    2015-01-01

    Multiple cases of attempted bioterrorism events using biotoxins have highlighted the urgent need for tools capable of rapid screening of suspect samples in the field (e.g., mailroom and public events). We present a portable microfluidic device capable of analyzing environmental (e.g., white powder), food (e.g., milk) and clinical (e.g., blood) samples for multiplexed detection of biotoxins. The device is rapid (<15-30 min sample-to-answer), sensitive (< 0.08 pg/mL detection limit for botulinum toxin), multiplexed (up to 64 parallel assays) and capable of analyzing small volume samples (< 20 μL total sample input). The immunoassay approach (SpinDx) is based on binding of toxins in a sample to antibody-laden capture particles followed by sedimentation of particles through a density-media in a microfluidic disk and quantification using a laser-induced fluorescence detector. A direct, blinded comparison with a gold standard ELISA revealed a 5-fold more sensitive detection limit for botulinum toxin while requiring 250-fold less sample volume and a 30 minute assay time with a near unity correlation. A key advantage of the technique is its compatibility with a variety of sample matrices with no additional sample preparation required. Ultrasensitive quantification has been demonstrated from direct analysis of multiple clinical, environmental and food samples, including white powder, whole blood, saliva, salad dressing, whole milk, peanut butter, half and half, honey, and canned meat. We believe that this device can met an urgent need in screening both potentially exposed people as well as suspicious samples in mail-rooms, airports, public sporting venues and emergency rooms. The general-purpose immunodiagnostics device can also find applications in screening of infectious and systemic diseases or serve as a lab device for conducting rapid immunoassays.

  5. An Optimized Method for Quantification of Pathogenic Leptospira in Environmental Water Samples.

    Science.gov (United States)

    Riediger, Irina N; Hoffmaster, Alex R; Casanovas-Massana, Arnau; Biondo, Alexander W; Ko, Albert I; Stoddard, Robyn A

    2016-01-01

    Leptospirosis is a zoonotic disease usually acquired by contact with water contaminated with urine of infected animals. However, few molecular methods have been used to monitor or quantify pathogenic Leptospira in environmental water samples. Here we optimized a DNA extraction method for the quantification of leptospires using a previously described Taqman-based qPCR method targeting lipL32, a gene unique to and highly conserved in pathogenic Leptospira. QIAamp DNA mini, MO BIO PowerWater DNA and PowerSoil DNA Isolation kits were evaluated to extract DNA from sewage, pond, river and ultrapure water samples spiked with leptospires. Performance of each kit varied with sample type. Sample processing methods were further evaluated and optimized using the PowerSoil DNA kit due to its performance on turbid water samples and reproducibility. Centrifugation speeds, water volumes and use of Escherichia coli as a carrier were compared to improve DNA recovery. All matrices showed a strong linearity in a range of concentrations from 106 to 10° leptospires/mL and lower limits of detection ranging from Leptospira in environmental waters (river, pond and sewage) which consists of the concentration of 40 mL samples by centrifugation at 15,000×g for 20 minutes at 4°C, followed by DNA extraction with the PowerSoil DNA Isolation kit. Although the method described herein needs to be validated in environmental studies, it potentially provides the opportunity for effective, timely and sensitive assessment of environmental leptospiral burden.

  6. A software for radioactivity measurement of Ra, Th and K in environmental samples

    International Nuclear Information System (INIS)

    Miao Zhengqiang; Bao Min; Chang Yongfu

    2004-01-01

    Radio nuclides of soil, rock, construction material, and almost everything around us. There is growing concern about environmental radioactivity from both scientists and public from an institutional or a common point of view. The regulation and standard on evaluating radioactivity of environmental samples have been issued recently by the authorities. We have developed special purpose Gamma spectra analysis software named ErSpec. The software can effectively process and analyze Gamma spectra measured by a NaI(T1) spectrometry, and can give a relatively precise results of radioactivity of 226 Ra, 232 Th and 40 K in environmental samples. The main functions of ErSpec include, processing and analyzing Gamma spectra, displaying some useful information for users, generating report, managing user's priority, logging user's manipulation, etc. Because environmental samples usually have low radioactivity and have complex measurement conditions, relative method is employed in ErSpec, and Channel-by-Channel Least-Squared Estimation is adopted as spectra analyzing method. The arithmetic make use of information extracted from data of hundreds of channels, then give a rather good result. In ErSpec, by using external call of MatLAB Math Lib in Visual C++, accuracy and speed of calculation and robustness of software are improved distinctly. Object-Oriented Programming Method and ActiveX techniques are also employed in software designing and coding stage. (authors)

  7. Rapid and Automated Determination of Plutonium and Neptunium in Environmental Samples

    DEFF Research Database (Denmark)

    Qiao, Jixin

    This thesis presents improved analytical methods for rapid and automated determination of plutonium and neptunium in environmental samples using sequential injection (SI) based chromatography and inductively coupled plasma mass spectrometry (ICP-MS). The progress of methodology development in thi...... environmental risk monitoring and assessment, emergency preparedness and surveillance of contaminated areas....... for rapid and simultaneous determination of plutonium and neptunium within an SI system (Paper VI). The results demonstrate that the developed methods in this study are reliable and efficient for accurate assays of trace levels of plutonium and neptunium as demanded in different situations including...

  8. Contributions for the application of a phoswich detector on the analysis of environmental samples

    International Nuclear Information System (INIS)

    Dalaqua Junior, L.

    1989-01-01

    The characteristics of a phoswich detector and the parameters of the pulse shape descrimination system are evaluated aiming the application on environmental analysis by direct low level gamma ray spectrometry. The calibration curves and adjustments for the pulse discrimination, detector resolution and homogeneity measurements are presented. Background reduction and the 210 Pb detection eficiency on evaporated sources are evaluated. The results obtained demonstrates the application potentiality on the analysis of environmental samples due to a high detection eficiency and good geometry conditions to the measurements. (author) [pt

  9. Particle transport in a He-microchip plasma atomic emission system with an ultrasonic nebulizer for aqueous sample introduction

    International Nuclear Information System (INIS)

    Oh, Joosuck; Lim, H.B.

    2008-01-01

    The transport efficiency of dried particles generated from an ultrasonic nebulizer (USN) was studied to improve the analytical performance of a lab-made, He-microchip plasma system, in which a quartz tube (∼ 1 mm i.d.) was positioned inside the central channel of a poly(dimethylsiloxane) (PDMS) polymer chip. The polymer microchip plasma has the advantages of low cost, small size, easy handling and design, and self-ignition with long stabilization (> 24 h). However, direct introduction of aqueous solution into the microplasma for the detection of metals remains problematic due to plasma instability. In addition, the much smaller size of the system can cause signal suppression due to low transport efficiency. Therefore, knowledge of particle transport efficiency in this microplasma system is required to enhance the sensitivity and stability. The weight of transported particles in the range of 0.02 to 10 mg m -3 was measured using a piezobalance with a precision of 0.4-17.8%, depending on the operating conditions. The significant effects of the USN operating conditions and the physical properties of the tubing, namely, length, inner diameter and surface characteristics, on the number of particles transported from the nebulizer to the microplasma were studied. When selected metals, such as Na, Mg and Pb, at a concentration of 5 mg L -1 were nebulized, transported particles were obtained with a mass range of 0.5-5 mg m -3 , depending on atomic weights. For application of the He-rf-microplasma, the atomic emission system was optimized by changing both the radio frequency (rf) power (60-200 W) and cooling temperature of the USN (- 12-9 deg. C). The limits of detection obtained for K, Na and Cu were 0.26, 0.22, and 0.28 mg L -1 , respectively. These results confirmed the suitable stability and sensitivity of the He-rf-PDMS microchip plasma for application as an atomization source

  10. Isolation and identification of salmonella from curry samples and its sensitivity to commercial antibiotics and aqueous extracts of Camelia sinensis (L.) and Trachyspermum ammi (L.).

    Science.gov (United States)

    Gunasegaran, Thanes; Rathinam, Xavier; Kasi, Marimuthu; Sathasivam, Kathiresan; Sreenivasan, Sasidharan; Subramaniam, Sreeramanan

    2011-08-01

    To isolate Salmonella from curry samples and to evaluate the drug sensitivity of the food-borne Salmonella and its susceptibility to specific plant extracts. Salmonella was isolated from the curry samples by standard microbiological methods and was confirmed by biochemical tests. The antibiotic susceptibility test was conducted by disc diffusion method using commercially available antibiotics such as ampicillin, tetracycline, chloramphenicol, kanamycin, and penicillin. In addition, the susceptibility of the food-borne Salmonella was also evaluated against the aqueous extracts of Camelia sinensis (L.) Theaceae (tea leaves) and the Trachyspermum ammi (L.) Apiaceae ( ajwain or omum seeds). Out of fifty curry samples, only seven samples were identified to have Salmonella contamination. The Salmonella isolates showed a significant drug resistance pattern except for kanamycin. The plant extracts showed a considerable antibacterial activity against the isolates, indicating the presence of antimicrobial principle which can be exploited after complete pharmacological investigations. The present study demonstrates the occurrence of Salmonella in the curry samples, and shows significant drug resistance against most of the commercially available antibiotics, except kanamycin. Antimicrobial effect of the plant extracts against the food-bone Salmonella suggests that dietary including medicinal herbs would be one strategy to manage food borne pathogens.

  11. Graphene-Derivatized Silica Composite as Solid-Phase Extraction Sorbent Combined with GC–MS/MS for the Determination of Polycyclic Musks in Aqueous Samples

    Directory of Open Access Journals (Sweden)

    Cheng Li

    2018-02-01

    Full Text Available Polycyclic musks (PCMs have recently received growing attention as emerging contaminants because of their bioaccumulation and potential ecotoxicological effects. Herein, an effective method for the determination of five PCMs in aqueous samples is presented. Reduced graphene oxide-derivatized silica (rGO@silica particles were prepared from graphene oxide and aminosilica microparticles and characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, and X-ray photoelectron spectroscopy. PCMs were preconcentrated using rGO@silica as the solid-phase extraction sorbent and quantified by gas chromatography–tandem mass spectrometry. Several experimental parameters, such as eluent, elution volume, sorbent amount, pH, and sample volume were optimized. The correlation coefficient (R ranged from 0.9958 to 0.9992, while the limits of detection and quantitation for the five PCMs were 0.3–0.8 ng/L and 1.1–2.1 ng/L, respectively. Satisfactory recoveries were obtained for tap water (86.6–105.9% and river water samples (82.9–107.1%, with relative standard deviations <10% under optimal conditions. The developed method was applied to analyze PCMs in tap and river water samples from Beijing, China. Galaxolide (HHCB and tonalide (AHTN were the main PCM components detected in one river water sample at concentrations of 18.7 for HHCB, and 11.7 ng/L for AHTN.

  12. A dispersive liquid--liquid microextraction methodology for copper (II) in environmental samples prior to determination using microsample injection flame atomic absorption spectrometry.

    Science.gov (United States)

    Alothman, Zeid A; Habila, Mohamed; Yilmaz, Erkan; Soylak, Mustafa

    2013-01-01

    A simple, environmentally friendly, and efficient dispersive liquid-liquid microextraction method combined with microsample injection flame atomic absorption spectrometry was developed for the separation and preconcentration of Cu(II). 2-(5-Bromo-2-pyridylazo)-5-(diethylamino)phenol (5-Br-PADAP) was used to form a hydrophobic complex of Cu(II) ions in the aqueous phase before extraction. To extract the Cu(II)-5-Br-PADAP complex from the aqueous phase to the organic phase, 2.0 mL of acetone as a disperser solvent and 200 microL of chloroform as an extraction solvent were used. The influences of important analytical parameters, such as the pH, types and volumes of the extraction and disperser solvents, amount of chelating agent, sample volume, and matrix effects, on the microextraction procedure were evaluated and optimized. Using the optimal conditions, the LOD, LOQ, preconcentration factor, and RSD were determined to be 1.4 microg/L, 4.7 microg/L, 120, and 6.5%, respectively. The accuracy of the proposed method was investigated using standard addition/recovery tests. The analysis of certified reference materials produced satisfactory analytical results. The developed method was applied for the determination of Cu in real samples.

  13. Semi-nested polymerase chain reaction for detection of toxigenic Vibrio cholerae from environmental water samples.

    Science.gov (United States)

    Goel, Ajay Kumar; Bhadauria, Shweta; Kumar, Pramod; Kamboj, Dev V; Singh, Lokendra

    2007-09-01

    A rapid and sensitive direct cell semi-nested PCR assay was developed for the detection of viable toxigenic V. cholerae in environmental water samples. The semi-nested PCR assay amplified cholera toxin (ctxA2B) gene present in the toxigenic V. cholerae. The detection sensitivity of direct cell semi-nested PCR was 2 × 10(3) CFU of V. cholerae whereas direct cell single-step PCR could detect 2 × 10(4) CFU of V. cholerae. The performance of the assay was evaluated using environmental water samples after spiking with known number of Vibrio cholerae O1. The spiked water samples were filtered through a 0.22 micrometer membrane and the bacteria retained on filters were enriched in alkaline peptone water and then used directly in the PCR assay. The semi-nested PCR procedure coupled with enrichment could detect less than 1 CFU/ml in ground water and sea water whereas 2 CFU/ml and 20 CFU/ml could be detected in pond water and tap water, respectively. The proposed method is simple, faster than the conventional detection assays and can be used for screening of drinking water or environmental water samples for the presence of toxigenic V. cholerae.

  14. Technical Note: New methodology for measuring viscosities in small volumes characteristic of environmental chamber particle samples

    Directory of Open Access Journals (Sweden)

    L. Renbaum-Wolff

    2013-01-01

    Full Text Available Herein, a method for the determination of viscosities of small sample volumes is introduced, with important implications for the viscosity determination of particle samples from environmental chambers (used to simulate atmospheric conditions. The amount of sample needed is < 1 μl, and the technique is capable of determining viscosities (η ranging between 10−3 and 103 Pascal seconds (Pa s in samples that cover a range of chemical properties and with real-time relative humidity and temperature control; hence, the technique should be well-suited for determining the viscosities, under atmospherically relevant conditions, of particles collected from environmental chambers. In this technique, supermicron particles are first deposited on an inert hydrophobic substrate. Then, insoluble beads (~1 μm in diameter are embedded in the particles. Next, a flow of gas is introduced over the particles, which generates a shear stress on the particle surfaces. The sample responds to this shear stress by generating internal circulations, which are quantified with an optical microscope by monitoring the movement of the beads. The rate of internal circulation is shown to be a function of particle viscosity but independent of the particle material for a wide range of organic and organic-water samples. A calibration curve is constructed from the experimental data that relates the rate of internal circulation to particle viscosity, and this calibration curve is successfully used to predict viscosities in multicomponent organic mixtures.

  15. A DOE manual: DOE Methods for Evaluating Environmental and Waste Management Samples

    International Nuclear Information System (INIS)

    Goheen, S.C.; McCulloch, M.; Riley, R.G.

    1994-01-01

    Waste Management inherently requires knowledge of the waste's chemical composition. The waste can often be analyzed by established methods; however, if the samples are radioactive, or are plagued by other complications, established methods may not be feasible. The US Department of Energy (DOE) has been faced with managing some waste types that are not amenable to standard or available methods, so new or modified sampling and analysis methods are required. These methods are incorporated into DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods), which is a guidance/methods document for sampling and analysis activities in support of DOE sites. It is a document generated by consensus of the DOE laboratory staff and is intended to fill the gap within existing guidance documents (e. g., the Environmental Protection Agency's (EPA's) Test Methods for Evaluating Solid Waste, SW-846), which apply to low-level or non-radioactive samples. DOE Methods fills the gap by including methods that take into account the complexities of DOE site matrices. The most recent update, distributed in October 1993, contained quality assurance (QA), quality control (QC), safety, sampling, organic analysis, inorganic analysis, and radioanalytical guidance as well as 29 methods. The next update, which will be distributed in April 1994, will contain 40 methods and will therefore have greater applicability. All new methods are either peer reviewed or labeled ''draft'' methods. Draft methods were added to speed the release of methods to field personnel

  16. Virulence Factors Detection inAspergillusIsolates from Clinical and Environmental Samples.

    Science.gov (United States)

    Raksha; Singh, Gurjeet; Urhekar, A D

    2017-07-01

    Pathogenesis of aspergillosis is dependent on various factors of the host (immune status) and virulence factors of the pathogen which could play a significant role in the pathogenesis of invasive aspergillosis. To study the virulence factors of Aspergillus species isolated from patient samples and environmental samples. This prospective and experimental study was carried out at Department of Microbiology, MGM Medical College and Hospital, Mumbai, Maharashtra, India, from July 2014 to June 2015. For detection of virulence factors of Aspergillus species, total 750 samples were included in this study (350 from patients and 400 samples from environment). Patient samples and hospital environment samples were subjected to standard methods for screening of Biofilm, Lipase, α-amylase, proteinase, haemolysin, phospholipase and pectinase. Statistical analysis was done using Chi-square test and SPSS (Version 17.0). American Type Culture Collection (ATCC) control of Aspergillus oryzae, Aspergillus niger and Aspergillus brasiliensis showed production of all virulence factors. In patient samples maximum virulence factor was produced i.e., α-amylase activity (89.74%) followed by proteinase activity (87.17%), biofilm production was (82.05%) haemolysin activity (79.48%), lipase activity (66.66%), pectinase activity and phospholipase activity (61.53%). In environment samples maximum virulence factor was produced i.e., proteinase activity (41.02%) followed by biofilm production was (38.46%), α-amylase activity (35.89%), haemolysin activity (33.33%), lipase activity (28.20%), phospholipase (25.64%) and pectinase activity (23.07%). The differences in patient and environment virulence factors were statistically significant (p-value Aspergillus species isolated from patient samples then environmental samples. This could be due to invasiveness nature of Aspergilli. Aspergillus niger was common isolates from both patient and environmental samples. Our study highlights the possible

  17. Virulence Factors Detection in Aspergillus Isolates from Clinical and Environmental Samples

    Science.gov (United States)

    Raksha; Urhekar, A.D.

    2017-01-01

    Introduction Pathogenesis of aspergillosis is dependent on various factors of the host (immune status) and virulence factors of the pathogen which could play a significant role in the pathogenesis of invasive aspergillosis. Aim To study the virulence factors of Aspergillus species isolated from patient samples and environmental samples. Materials and Methods This prospective and experimental study was carried out at Department of Microbiology, MGM Medical College and Hospital, Mumbai, Maharashtra, India, from July 2014 to June 2015. For detection of virulence factors of Aspergillus species, total 750 samples were included in this study (350 from patients and 400 samples from environment). Patient samples and hospital environment samples were subjected to standard methods for screening of Biofilm, Lipase, α–amylase, proteinase, haemolysin, phospholipase and pectinase. Statistical analysis was done using Chi-square test and SPSS (Version 17.0). Results American Type Culture Collection (ATCC) control of Aspergillus oryzae, Aspergillus niger and Aspergillus brasiliensis showed production of all virulence factors. In patient samples maximum virulence factor was produced i.e., α-amylase activity (89.74%) followed by proteinase activity (87.17%), biofilm production was (82.05%) haemolysin activity (79.48%), lipase activity (66.66%), pectinase activity and phospholipase activity (61.53%). In environment samples maximum virulence factor was produced i.e., proteinase activity (41.02%) followed by biofilm production was (38.46%), α-amylase activity (35.89%), haemolysin activity (33.33%), lipase activity (28.20%), phospholipase (25.64%) and pectinase activity (23.07%). The differences in patient and environment virulence factors were statistically significant (p-value Aspergillus species isolated from patient samples then environmental samples. This could be due to invasiveness nature of Aspergilli. Aspergillus niger was common isolates from both patient and environmental

  18. Materials and Methods for Streamlined Laboratory Analysis of Environmental Samples, FY 2016 Report

    Energy Technology Data Exchange (ETDEWEB)

    Addleman, Raymond S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Naes, Benjamin E. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McNamara, Bruce K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Olsen, Khris B. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Chouyyok, Wilaiwan [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Willingham, David G. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Spigner, Angel C. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-11-30

    The International Atomic Energy Agency (IAEA) relies upon laboratory analysis of environmental samples (typically referred to as “swipes”) collected during on-site inspections of safeguarded facilities to support the detection and deterrence of undeclared activities. Unfortunately, chemical processing and assay of the samples is slow and expensive. A rapid, effective, and simple extraction process and analysis method is needed to provide certified results with improved timeliness at reduced costs (principally in the form of reduced labor), while maintaining or improving sensitivity and efficacy. To address these safeguard needs the Pacific Northwest National Laboratory (PNNL) explored and demonstrated improved methods for environmental sample (ES) analysis. Improvements for both bulk and particle analysis were explored. To facilitate continuity and adoption, the new sampling materials and processing methods will be compatible with existing IAEA protocols for ES analysis. PNNL collaborated with Oak Ridge National Laboratory (ORNL), which performed independent validation of the new bulk analysis methods and compared performance to traditional IAEA’s Network of Analytical Laboratories (NWAL) protocol. ORNL efforts are reported separately. This report describes PNNL’s FY 2016 progress, which was focused on analytical application supporting environmental monitoring of uranium enrichment plants and nuclear fuel processing. In the future the technology could be applied to other safeguard applications and analytes related to fuel manufacturing, reprocessing, etc. PNNL’s FY 2016 efforts were broken into two tasks and a summary of progress, accomplishments and highlights are provided below. Principal progress and accomplishments on Task 1, Optimize Materials and Methods for ICP-MS Environmental Sample Analysis, are listed below. • Completed initial procedure for rapid uranium extraction from ES swipes based upon carbonate-peroxide chemistry (delivered to ORNL for

  19. Ultra-sensitive trace element analysis of environmental samples using advanced TRXRF techniques

    International Nuclear Information System (INIS)

    Schwenke, H.; Knoth, J.; Michaelis, W.

    1980-01-01

    X-ray fluorescence analysis is a widely adopted technique for measuring elemental concentrations in a variety of sample species. The particular advantages compared to other methods are simplicity in instrumentation, rapidity of measurement and the high degree of automation attainable. In trace element analysis, however, the sensitivity of conventional x-ray fluorescence analysis is often insufficient. The paper describes a new type of energy-dispersive equipment which reveals ultimate performance with respect to detection limits and which thus considerably extends the applicability of XRF analysis. The essential feature of the system is the utilization of multiple total reflection (TR) of the exciting x-ray beam from polished quartz glass surfaces. Since the refractive index is slightly smaller than 1, total reflection occurs if the radiation strikes the surface at angles of less than 5'. The grazing incident beam from a fine-structure x-ray tube is twice reflected and follows a zigzag path before it is directed to the sample prepared as a thin film on the third quartz glass surface. The direct beam and scattered radiation are eliminated by diaphragms. In this way, a further reduction of the background in the fluorescence spectrum is achieved compared to a previously published version with single reflection of the exciting beam. The performance of the instrument leads to detection limits for aqueous solutions below 10 -11 g or 0.1 ppB, respectively, for at least 20 elements

  20. Validated methodology for quantifying infestation levels of dreissenid mussels in environmental DNA (eDNA) samples.

    Science.gov (United States)

    Peñarrubia, Luis; Alcaraz, Carles; Vaate, Abraham Bij de; Sanz, Nuria; Pla, Carles; Vidal, Oriol; Viñas, Jordi

    2016-12-14

    The zebra mussel (Dreissena polymorpha Pallas, 1771) and the quagga mussel (D. rostriformis Deshayes, 1838) are successful invasive bivalves with substantial ecological and economic impacts in freshwater systems once they become established. Since their eradication is extremely difficult, their detection at an early stage is crucial to prevent spread. In this study, we optimized and validated a qPCR detection method based on the histone H2B gene to quantify combined infestation levels of zebra and quagga mussels in environmental DNA samples. Our results show specific dreissenid DNA present in filtered water samples for which microscopic diagnostic identification for larvae failed. Monitoring a large number of locations for invasive dreissenid species based on a highly specific environmental DNA qPCR assay may prove to be an essential tool for management and control plans focused on prevention of establishment of dreissenid mussels in new locations.

  1. Prevalence of L. monocytogenes in environmental samples collected in dairy plants of Sassari Province, Italy

    Directory of Open Access Journals (Sweden)

    Giovanni Terrosu

    2015-09-01

    Full Text Available Listeria (L. monocytogenes is frequently isolated from food production environment and often persists in dairy plants despite vigorous sanitation regimes. In recent years several alert notifications were sent to Rapid Alert System for Food Products system as a consequence of Listeria monocytogenes contamination of ricotta cheese. After the alert of 2012, competent authority (Local Health Unit of Sassari Province organised an environmental monitoring plan with the partnership of the Institute for Experimental Veterinary Medicine of Sardinia to verify analysis of dairy plants own-check according to Regulation (EC N° 2073/05 and further modifications. In 2014 n. 665 processing areas samples of n. 50 dairy plants of Sassari Province were examined. UNI EN ISO 11290-1:2005 for detection of L. monocytogenes was used. Non-compliance in n. 5 diary plants are observed (n. 8 positive samples. Post-non-compliance environmental sanitisation was efficient and own-check plans included appropriate corrective actions.

  2. A novel voltammetric method for the direct determination of copper in complex environmental samples.

    Science.gov (United States)

    Xia, Jianjun; Wei, Wanzhi; Hu, Yanbo; Tao, Han; Wu, Ling

    2004-07-01

    A novel voltammetry with a modified gold electrode for the direct determination of copper in environmental samples, without any pretreatment, is proposed in this paper. A porous disorganized monolayer was formed on the surface of the gold electrode by the self-assembly of mercaptoacetic acid (MAA), which could selectively permeate small molecules. Subtractive square wave anodic stripping voltammetry (SASV) was applied to determine copper, in which the underpotential deposition (UPD) of copper was used as the deposition step. The linear range was from 8 x 10(-7) to 1 x l0(-5) mol l(-1) by the modified electrode in the presence of human serum albumin, and the determination was not interfered with common metal ions. Copper in a real environmental sample was successfully detected.

  3. Specific calibration problems for gammaspectrometric measurements of low-level radioactivity in environmental samples

    Energy Technology Data Exchange (ETDEWEB)

    Arnold, D. [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany); Wershofen, H. [Physikalisch-Technische Bundesanstalt, Braunschweig (Germany)

    1997-03-01

    Gammaspectrometric measurements of low-level radioactivity in environmental samples are always done in a close source detector geometry. This geometry causes coincidence-summing effects for measurements of multi-photon emitting nuclides. The measurements of radioactivity in environmental samples are also influenced by the absorption of photons in the materials which have to be analysed. Both effects must be taken into account by correction factors with respect to an energy-specific calibration of the detector system for a given geometry and a given composition of the calibration source. The importance of these corrections is emphasized. It is the aim of the present paper to compare different experimental and theoretical methods for the determination of these correction factors published by various authors and to report about efforts to refine them. (orig.)

  4. Determination of trace benzene derivatives in aqueous samples by ultrasonic enhanced hollow fiber liquid-phase microextraction prior to gas chromatography.

    Science.gov (United States)

    Wang, Lei; Guo, Yugao; Liang, Shumei; Yang, Qingqing; Wei, Junfu

    2011-10-01

    A new method was developed for the determination of trace compounds in water samples using ultrasonic-enhanced hollow fiber liquid-phase microextraction (U-HF-LPME). The ultrasonic radiation, which produces mechanical vibration and ultrasonic cavitation, could be used for accelerating the diffusion mass transfer process. Thus, ultrasonic was introduced into the HF-LPME procedure to enhance the mass-transfer rate during the aqueous and extraction solvent phases. Experimental parameters such as the extraction solvent, the extraction time, the ultrasonic frequency and power, the extractant volume, and ionic strength of the sample were assessed and optimized. Under optimal conditions, HF-LPME was achieved within 10 min. The high enrichment factor in the range of 120-666 and a good relative recovery in the range of 97-103% were evaluated with the relative standard deviations (RSDs, n = 5) of 0.3-7.0%. The limit of detection was in the range of 0.8-3.0 µg/L. The method was applied to the analysis of groundwater, lake water, and seawater. The results showed that the method can determine trace benzene derivatives in real samples with RSD values of 1.1-4.2%. The results demonstrated that U-HF- LPME is a rapid, accurate, and effective sample preparation method, and could be successfully applied for the determination of trace compounds in analytical chemistry.

  5. Preconcentration and determination of trace metal ions from aqueous samples by newly developed gallic acid modified Amberlite XAD-16 chelating resin.

    Science.gov (United States)

    Sharma, R K; Pant, Parul

    2009-04-15

    Gallic acid was immobilized on Amberlite XAD-16 by coupling it through -N=N group. The resulting chelating resin Amberlite XAD-16 gallic acid, characterized by thermogravimetric analysis (TGA), infrared (IR) spectra and BET analysis, was used to preconcentrate Cr(III), Mn(II),Fe(III),Co(II), Ni(II) and Cu(II)ions. The resin was employed for the preconcentration of the metal ions present in river water and industrial area aqueous samples. Several parameters like effect of pH, effect of time, effect of sample volume and flow rate of sample were investigated. The sorption capacities for the resin were 216 micromol g(-1), 180 micromol g(-1), 403 micromol g(-1), 281 micromol g(-1), 250 micromol g(-1) and 344 micromol g(-1) for Cr(III), Mn(II), Fe(III), Co(II), Ni(II) and Cu(II) respectively. The preconcentration factors for Cr(III), Mn(II), Fe(III), Ni(II), Co(II) and Cu(II) were found out to be 300, 200, 400, 285.7, 300 and 400 respectively. The effect of various interfering ions was also studied. Results were validated by using standard addition method for river water sample.

  6. Modern Trends in Neutron Activation Analysis. Applications to some African Environmental Samples

    International Nuclear Information System (INIS)

    Hassan, A.M.

    2009-01-01

    This review covers the results of several published articles which deal with the modern trends in neutron activation analysis techniques using some of African research reactors for some environmental samples. The samples used have been collected from different areas in Egypt, South Africa, Ghana, Morocco, Nigeria, and Algeria. The neutron irradiation facilities and the advanced detection systems in each country are outlined. The prompt and delayed gamma-rays emitted due to neutron capture have been applied for investigation of the elemental constituents of such samples. Covered applications include exploration, mining, industrial environment, pollution of air, foodstuffs, soils and irrigation water samples. Some of the developed software programmes as well as the modern methods of data analysis are presented. The thermal and epithermal neutron activation analysis techniques have been applied for estimation of major, minor and trace elements in each material. Some of these data are presented with several comments.

  7. Aspects of cleaning environmental materials for multi-element analysis, e.g. plant samples

    International Nuclear Information System (INIS)

    Markert, B.

    1992-01-01

    Cleaning of samples is often the first step in the entire procedure of sample preparation in environmental trace element research. The question must generally be raised of whether cleaning is meaningful before chemical investigations with plant material (e.g. for the determination of transfer factors in the soil/plant system) or not (e.g. for food chain analysis in the plant/animal system). The most varied cleaning procedures for plant samples are currently available ranging from dry and wet wiping of the leaf or needle surface up to the complete removal of the cuticule with the aid of chlorofom. There is at present no standardized cleaning procedure for plant samples so that it is frequently not possible to compare analytical data from different working groups studying the same plant species. (orig.)

  8. Measurements of 222Rn and 226Ra Levels in environmental samples by using liquid scintillation counter

    International Nuclear Information System (INIS)

    Moustafa, A.S.

    2004-01-01

    The advantageous of liquid scintillation counting technique for 6 Ra determination compared with other methods are the high counting efficiency and the easier sample preparation, with no need for sample pre-concentration. In this work, liquid scintillation counting system was used to measure 222 Rn and 226 Ra levels in environmental samples. The liquid scintillation cocktail was prepared in the laboratory and was found efficient for measuring 222 Rn. Soil, sediment and TENORM samples were dried, grind, sieved and added to hydrochloric acid, in a standard scintillation vial, preloaded with the liquid scintillation cocktail. By measuring 222 Rn levels in the prepared vials, at different intervals of time after preparation, 222 Rn and 226 Ra levels were determined

  9. Improvements to sample processing and measurement to enable more widespread environmental application of tritium.

    Science.gov (United States)

    Moran, James; Alexander, Thomas; Aalseth, Craig; Back, Henning; Mace, Emily; Overman, Cory; Seifert, Allen; Freeburg, Wilcox

    2017-08-01

    Previous measurements have demonstrated the wealth of information that tritium (T) can provide on environmentally relevant processes. We present modifications to sample preparation approaches that enable T measurement by proportional counting on small sample sizes equivalent to 120mg of water and demonstrate the accuracy of these methods on a suite of standardized water samples. We identify a current quantification limit of 92.2 TU which, combined with our small sample sizes, correlates to as little as 0.00133Bq of total T activity. This enhanced method should provide the analytical flexibility needed to address persistent knowledge gaps in our understanding of both natural and artificial T behavior in the environment. Copyright © 2017. Published by Elsevier Ltd.

  10. Basic distribution free identification tests for small size samples of environmental data

    International Nuclear Information System (INIS)

    Federico, A.G.; Musmeci, F.

    1998-01-01

    Testing two or more data sets for the hypothesis that they are sampled form the same population is often required in environmental data analysis. Typically the available samples have a small number of data and often then assumption of normal distributions is not realistic. On the other hand the diffusion of the days powerful Personal Computers opens new possible opportunities based on a massive use of the CPU resources. The paper reviews the problem introducing the feasibility of two non parametric approaches based on intrinsic equi probability properties of the data samples. The first one is based on a full re sampling while the second is based on a bootstrap approach. A easy to use program is presented. A case study is given based on the Chernobyl children contamination data [it

  11. Evaluating the suitability of different environmental samples for tracing atmospheric pollution in industrial areas.

    Science.gov (United States)

    Francová, Anna; Chrastný, Vladislav; Šillerová, Hana; Vítková, Martina; Kocourková, Jana; Komárek, Michael

    2017-01-01

    Samples of lichens, snow and particulate matter (PM 10 , 24 h) are used for the source identification of air pollution in the heavily industrialized region of Ostrava, Upper Silesia, Czech Republic. An integrated approach that uses different environmental samples for metal concentration and Pb isotope analyses was applied. The broad range of isotope ratios in the samples indicates a combination of different pollution sources, the strongest among them being the metallurgical industry, bituminous coal combustion and traffic. Snow samples are proven as the most relevant indicator for tracing metal(loid)s and recent local contamination in the atmosphere. Lichens can be successfully used as tracers of the long-term activity of local and remote sources of contamination. The combination of PM 10 with snow can provide very useful information for evaluation of current pollution sources. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Methods of liquid phase microextraction for the determination of cadmium in environmental samples.

    Science.gov (United States)

    Pires Santos, Analú; das Graças Andrade Korn, Maria; Azevedo Lemos, Valfredo

    2017-08-09

    Liquid phase microextraction (LPME) has been widely used in extraction and preconcentration systems as an excellent alternative to conventional liquid phase extraction. In this work, a critical review is presented on liquid phase microextraction techniques used in the determination of cadmium in environmental samples. LPME techniques are classified into three main groups: single-drop liquid phase microextraction (SDME), hollow fiber liquid phase microextraction (HF-LPME), and dispersive liquid-liquid microextraction (DLLME). Methods involving these liquid phase microextraction techniques are described, addressing advantages and disadvantages, samples, figures of merit, and trends.

  13. A comparison of microscopic and spectroscopic identification methods for analysis of microplastics in environmental samples.

    Science.gov (United States)

    Song, Young Kyoung; Hong, Sang Hee; Jang, Mi; Han, Gi Myung; Rani, Manviri; Lee, Jongmyoung; Shim, Won Joon

    2015-04-15

    The analysis of microplastics in various environmental samples requires the identification of microplastics from natural materials. The identification technique lacks a standardized protocol. Herein, stereomicroscope and Fourier transform infrared spectroscope (FT-IR) identification methods for microplastics (microplastics were significantly (p0.05) different. Depending on the number of samples and the microplastic size range of interest, the appropriate identification method should be determined; selecting a suitable identification method for microplastics is crucial for evaluating microplastic pollution. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Environmental DNA from seawater samples correlate with trawl catches of Subarctic, deepwater fishes

    DEFF Research Database (Denmark)

    Thomsen, Philip Francis; Møller, Peter Rask; Sigsgaard, Eva Egelyng

    2016-01-01

    such as bottom trawling, and on official reporting of global catches, which can be unreliable. Thus, there is need for alternative and non-invasive techniques for qualitative and quantitative oceanic fish surveys. Here we report environmental DNA (eDNA) metabarcoding of seawater samples from continental slope...... depths in Southwest Greenland. We collected seawater samples at depths of 188-918 m and compared seawater eDNA to catch data from trawling. We used Illumina sequencing of PCR products to demonstrate that eDNA reads show equivalence to fishing catch data obtained from trawling. Twenty-six families were...

  15. High efficiency environmental sampling with UV-cured peelable coatings (aka NuGoo project)

    Energy Technology Data Exchange (ETDEWEB)

    Henzl, Vladimir [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Junghans, Sylvia Ann [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Lakis, Rollin Evan [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2017-11-21

    This report presents slides on CA Related Project (FY13-17); Environmental sampling by IAEA (not only) during CA; Decontamination gels; Cotton swipes vs. decon gel (FY15); Contamination removal study; The origins of the NuGoo; NuGoo – proof of concept; NuGoo – FY17 project ($250K); LED lamp – which one works and why; Selecting photoinitiator; Monomers and oligomers; Results.

  16. Practice and experience in traceability of radioactivity measurements of environmental samples

    International Nuclear Information System (INIS)

    Huang Zhijian

    1990-01-01

    This paper discusses some aspects on radioactivity measurement traceability and summarizes the work on quality assurance of radioactivity measurements of environmental samples in the laboratory, including transfer of standards, preparation of reference materials, and calibration of efficiency for volumse surces with Ge(Li) spectrometer. Some practical activitis regarding intercomparison of radioactivity measurements and other traceabillity-related activities are also described. Some sugestions relating to performing quality assurance are made

  17. Transgenic zebrafish reveal tissue-specific differences in estrogen signaling in response to environmental water samples

    Science.gov (United States)

    Gorelick, Daniel A.; Iwanowicz, Luke R.; Hung, Alice L.; Blazer, Vicki; Halpern, Marnie E.

    2014-01-01

    Background: Environmental endocrine disruptors (EED) are exogenous chemicals that mimic endogenous hormones, such as estrogens. Previous studies using a zebrafish transgenic reporter demonstrated that the EEDs bisphenol A and genistein preferentially activate estrogen receptors (ER) in the larval heart compared to the liver. However, it was not known whether the transgenic zebrafish reporter was sensitive enough to detect estrogens from environmental samples, whether environmental estrogens would exhibit similar tissue-specific effects as BPA and genistein or why some compounds preferentially target receptors in the heart. Methods: We tested surface water samples using a transgenic zebrafish reporter with tandem estrogen response elements driving green fluorescent protein expression (5xERE:GFP). Reporter activation was colocalized with tissue-specific expression of estrogen receptor genes by RNA in situ hybridization. Results: Selective patterns of ER activation were observed in transgenic fish exposed to river water samples from the Mid-Atlantic United States, with several samples preferentially activating receptors in embryonic and larval heart valves. We discovered that tissue-specificity in ER activation is due to differences in the expression of estrogen receptor subtypes. ERα is expressed in developing heart valves but not in the liver, whereas ERβ2 has the opposite profile. Accordingly, subtype-specific ER agonists activate the reporter in either the heart valves or the liver. Conclusion: The use of 5xERE:GFP transgenic zebrafish has revealed an unexpected tissue-specific difference in the response to environmentally relevant estrogenic compounds. Exposure to estrogenic EEDs in utero is associated with adverse health effects, with the potentially unanticipated consequence of targeting developing heart valves.

  18. Real-Time PCR for Quantification of Giardia and Cryptosporidium in Environmental Water Samples and Sewage

    OpenAIRE

    Guy, Rebecca A.; Payment, Pierre; Krull, Ulrich J.; Horgen, Paul A.

    2003-01-01

    The protozoan pathogens Giardia lamblia and Cryptosporidium parvum are major causes of waterborne enteric disease throughout the world. Improved detection methods that are very sensitive and rapid are urgently needed. This is especially the case for analysis of environmental water samples in which the densities of Giardia and Cryptosporidium are very low. Primers and TaqMan probes based on the β-giardin gene of G. lamblia and the COWP gene of C. parvum were developed and used to detect DNA co...

  19. An Optimized Method for Quantification of Pathogenic Leptospira in Environmental Water Samples

    OpenAIRE

    Riediger, Irina N.; Hoffmaster, Alex R.; Casanovas-Massana, Arnau; Biondo, Alexander W.; Ko, Albert I.; Stoddard, Robyn A.

    2016-01-01

    Leptospirosis is a zoonotic disease usually acquired by contact with water contaminated with urine of infected animals. However, few molecular methods have been used to monitor or quantify pathogenic Leptospira in environmental water samples. Here we optimized a DNA extraction method for the quantification of leptospires using a previously described Taqman-based qPCR method targeting lipL32, a gene unique to and highly conserved in pathogenic Leptospira. QIAamp DNA mini, MO BIO PowerWater DNA...

  20. A very sensitive LSC procedure to determine Ni-63 in environmental samples, steel and concrete

    International Nuclear Information System (INIS)

    Scheuerer, C.; Schupfner, R.; Schuettelkopf, H.

    1995-01-01

    This procedure to determine Ni-63 contributes to a safe and economically reasonable decommissioning of nuclear power plants. Co-60, Fe-55 and Ni-63 are the most abundant long-lived radionuclides associated with contaminated piping, hardware and concrete for a period of several decades of years after shutdown. Samples are carefully ashed leached, or dissolved by suitable mixtures of acids. The analysis starts with the absorption Ni 2+ on the chelating resin CHELEX 100. The next purification steps include an anionic exchange column and a precipitation as Ni-dimethyl-glyoxime, which is extracted into chloroform. After reextraction with sulfuric acid the solution containing Ni 2+ is mixed with a scintillation cocktail and counted in an anticoincidence shielded LSC. The decontamination factors are determined for all important artificially and naturally occurring radionuclides ranging form above 10 4 to 10 9 . The chemical yield adopts a value of (95±5)%. Up to maximum sample amounts of 0.4 g steel, 5 g concrete and about 100 g of environmental samples the detection limits are about 5 mBq per sample or 12 mBq/g steel, 1 mBq/g concrete and 0.05 mBq/g environmental sample at a counting time of 1000 minutes. (author) 16 refs.; 2 figs.; 2 tabs

  1. Evaluation of the Environmental Supports Scale with a Community Sample of Adolescents.

    Science.gov (United States)

    Risco, Cristina M; Collado, Anahi D; Reynolds, Elizabeth K; Lejuez, Carl W; MacPherson, Laura

    2016-05-01

    Environmental sources of psychosocial support have been found to modulate or protect against the development of psychopathology and risk behavior among adolescents. Capturing sources of environmental support across multiple developmental contexts requires the availability of well-validated, concise assessments-of which there are few in the existing literature. In order to address this need, the current study explored the factor structure, concurrent and convergent validity of the Environmental Supports Scale (ESS; Genetic, Social, and General Psychology Monographs, 117; 395-417, 1991) with a community sample of adolescents. An unconstrained exploratory factor analysis revealed a separate factor for home, school, and neighborhood settings. Internal consistency and test-retest reliability were evaluated for each factor. Concurrent and predictive validity analyses revealed that the ESS was associated in the expected directions across a range of constructs relevant to adolescent development including internalizing symptoms, well-being, external influences, and engagement in risk behavior. Convergent validity for the neighborhood context was established with an assessment of neighborhood environmental adversity. A brief assessment of perceived environmental support across key developmental contexts provides an important tool for research on resilience processes during adolescence and may help illuminate key protective factors and inform intervention and prevention efforts.

  2. New developments in the extraction and determination of parabens in cosmetics and environmental samples. A review

    International Nuclear Information System (INIS)

    Ocaña-González, Juan Antonio; Villar-Navarro, Mercedes; Ramos-Payán, María; Fernández-Torres, Rut; Bello-López, Miguel Angel

    2015-01-01

    Highlights: • The analysis of parabens in cosmetics and environmental samples is reviewed. • Literature in this field from 1980 to 2003 is briefly discussed. • Determination and extraction methods in the last decade are discussed in-depth. - Abstract: Parabens are a family of synthetic esters of p-hydroxibenzoic acid widely used as preservatives in cosmetics and health-care products, among other daily-use commodities. Recently, their potential endocrine disrupting effects have raised concerns about their safety and their potential effects as emerging pollutants, leading to the regulation of the presence of parabens in commercial products by national and trans-national organizations. Also, this has led to an interest in developing sensible and reliable methods for their determination in environmental samples, cosmetics and health-care products. This paper is a comprehensive up-to-date review of the literature concerning the determination of parabens in environmental samples and cosmetic and health-care products. A brief revision of the literature concerning the traditional determination of parabens (1980–2003) is included, followed by an in-depth revision of the recent developments in both measurement and extraction methods for parabens in the last years (2003–2013). Finally, possible future perspectives in this field are proposed

  3. Dielectrophoretic sample preparation for environmental monitoring of microorganisms: Soil particle removal.

    Science.gov (United States)

    Fatoyinbo, Henry O; McDonnell, Martin C; Hughes, Michael P

    2014-07-01

    Detection of pathogens from environmental samples is often hampered by sensors interacting with environmental particles such as soot, pollen, or environmental dust such as soil or clay. These particles may be of similar size to the target bacterium, preventing removal by filtration, but may non-specifically bind to sensor surfaces, fouling them and causing artefactual results. In this paper, we report the selective manipulation of soil particles using an AC electrokinetic microfluidic system. Four heterogeneous soil samples (smectic clay, kaolinitic clay, peaty loam, and sandy loam) were characterised using dielectrophoresis to identify the electrical difference to a target organism. A flow-cell device was then constructed to evaluate dielectrophoretic separation of bacteria and clay in a continous flow through mode. The average separation efficiency of the system across all soil types was found to be 68.7% with a maximal separation efficiency for kaolinitic clay at 87.6%. This represents the first attempt to separate soil particles from bacteria using dielectrophoresis and indicate that the technique shows significant promise; with appropriate system optimisation, we believe that this preliminary study represents an opportunity to develop a simple yet highly effective sample processing system.

  4. New developments in the extraction and determination of parabens in cosmetics and environmental samples. A review

    Energy Technology Data Exchange (ETDEWEB)

    Ocaña-González, Juan Antonio; Villar-Navarro, Mercedes [Department of Analytical Chemistry, Faculty of Chemistry, Universidad de Sevilla, c/Prof. García González, s/n. 41012 Seville (Spain); Ramos-Payán, María [Department of Analytical Chemistry, Faculty of Chemistry, Universidad de Sevilla, c/Prof. García González, s/n. 41012 Seville (Spain); Department of Analytical Chemistry, Lineberguer Cancer Center, The University of North Carolina at Chapel Hill, NC (United States); Fernández-Torres, Rut [Department of Analytical Chemistry, Faculty of Chemistry, Universidad de Sevilla, c/Prof. García González, s/n. 41012 Seville (Spain); Research Centre of Health and Environment (CYSMA), University of Huelva (Spain); Bello-López, Miguel Angel, E-mail: mabello@us.es [Department of Analytical Chemistry, Faculty of Chemistry, Universidad de Sevilla, c/Prof. García González, s/n. 41012 Seville (Spain)

    2015-02-09

    Highlights: • The analysis of parabens in cosmetics and environmental samples is reviewed. • Literature in this field from 1980 to 2003 is briefly discussed. • Determination and extraction methods in the last decade are discussed in-depth. - Abstract: Parabens are a family of synthetic esters of p-hydroxibenzoic acid widely used as preservatives in cosmetics and health-care products, among other daily-use commodities. Recently, their potential endocrine disrupting effects have raised concerns about their safety and their potential effects as emerging pollutants, leading to the regulation of the presence of parabens in commercial products by national and trans-national organizations. Also, this has led to an interest in developing sensible and reliable methods for their determination in environmental samples, cosmetics and health-care products. This paper is a comprehensive up-to-date review of the literature concerning the determination of parabens in environmental samples and cosmetic and health-care products. A brief revision of the literature concerning the traditional determination of parabens (1980–2003) is included, followed by an in-depth revision of the recent developments in both measurement and extraction methods for parabens in the last years (2003–2013). Finally, possible future perspectives in this field are proposed.

  5. Measurement of Biologically Available Naphthalene in Gas and Aqueous Phases by Use of a Pseudomonas putida Biosensor

    NARCIS (Netherlands)

    Werlen, C.; Jaspers, M.C.M.; Meer, J.R. van der

    2004-01-01

    Genetically constructed microbial biosensors for measuring organic pollutants are mostly applied in aqueous samples. Unfortunately, the detection limit of most biosensors is insufficient to detect pollutants at low but environmentally relevant concentrations. However, organic pollutants with low

  6. Determination of Lewisites and their hydrolysis products in aqueous and multiphase samples by in-sorbent tube butyl thiolation followed by thermal desorption-gas chromatography-full scan mass spectrometry

    NARCIS (Netherlands)

    Terzic, O.; Bartenbach, S.; de Voogt, P.

    2013-01-01

    A rapid, sensitive and robust method for determining the chemical warfare agents Lewisites and their hydrolysis products in aqueous and multiphase sample matrices has been developed as an extension of the previous work (Terzic, 2010 [32]). In the new method, the acidification of the sample and use

  7. A measurement method for atmospheric ammonia and primary amines based on aqueous sampling, OPA derivatization and HPLC analysis.

    Science.gov (United States)

    Huang, Gu; Hou, Jian; Zhou, Xianliang

    2009-08-01

    A method of precolumn derivatization HPLC with fluorescence detection has been developed for the measurement of ammonia, primary methylamine, ethylamine, propylamine, and butylamine in the atmosphere. Air samples were collected by two continuously wetted glass frit/coil samplers, one directly from ambient air for the sum of gaseous and aerosol species, and the other after an acid-coated annular denuder for the aerosol species. The collection efficiency for all analytes was found to be > or = 99% at a sampling gas flow rate of 2 L min(-1) and a scrubbing water flow rate of 0.24 mL min(-1). The collected ammonia and primary amines were derivatized with o-phthalaldehyde (OPA) and n-acetyl-cysteine (NAC) reagents in an in-line derivatization coil to form highly fluorescent sulfonatoisoindole derivatives. Detailed kinetic study showed that derivatization reactions were fast but the derivatives were not very stable. Derivatization conditions, such as reagent concentrations, derivatication medium pH, and derivatization time, were optimized to achieve maximum derivative yields for all the analytes. The derivatives were separated on a C-18 reverse-phase column using a gradient elution and detected by a fluorescence detector at an excitation wavelength of 330 nm and an emission wavelength of 471 nm. The respective lower detection limits for ammonia and for the four primary amines were 24 parts per trillion by volume (pptv) and < or = 3 pptv, with a sample time resolution of about 1 min and a sampling/ analysis time of 20 win per cycle. The analytical methodology has been applied in the field measurements; results from two case studies are presented.

  8. Salmonella isolated from individual reptiles and environmental samples from terraria in private households in Sweden.

    Science.gov (United States)

    Wikström, Veronica O; Fernström, Lise-Lotte; Melin, Lennart; Boqvist, Sofia

    2014-01-24

    This study investigates Salmonella spp. isolated from privately kept reptiles and from environmental samples such as bedding materials or water from the floor of the enclosures (terraria). It also compares isolation of Salmonella using Modified Semisolid Rappaport-Vassiliadis (MSRV) medium or selective enrichment in Rappaport-Vassiliadis-Soya (RVS) pepton broth. Cloacal swabs or swabs from the cloacal area were collected from 63 individual reptiles belonging to 14 households. All reptiles were from different terraria and from 62 of these, environmental samples were also collected. Sampling were done by the reptile owners according to written instructions and sent by mail immediately after sampling. All but three samples were analyzed within 24 h after collection. Colonies suspected for Salmonella were tested for agglutination and serotyped using the White-Kauffmann-Le Minor scheme. The relative sensitivity (se) and specificity (sp) for MSRV compared with RVS, and the agreement coefficient kappa (κ) were calculated. Salmonella was isolated from 50/63 (80%) terraria, either from the reptiles (31/63; 49%) or from bedding material (39/62; 63%). The most common subspecies was Salmonella enterica subspecies enterica followed by S. enterica subspecies diarizonae. In reptiles, the most common S. enterica subspecies enterica serovars were Java (n = 4) and Fluntern (n = 4), compared with the serovars Tennessee (n = 10) and Fluntern (n = 10) in the environmental samples. The exact same set of Salmonella subspecies and serovars were not isolated from the individual reptiles and the environmental samples from any of the households. Isolation using MSRV yielded more Salmonella isolates 61/113 (54%) than enrichment in RVS 57/125 (46%). The se was 97.9% (95% Confidence Interval 93.9-100), the sp 78.5% (95% CI 68.5-88.5) and the κ 0.74, indicating substantial agreement between the tests. Salmonella can be expected to be present in environments where reptiles are

  9. Preparation Of Deposited Sediment Sample By Casting Method For Environmental Study

    International Nuclear Information System (INIS)

    Hutabarat, Tommy; Ristin PI, Evarista

    2000-01-01

    The preparation of deposited sediment sample by c asting m ethod for environmental study has been carried out. This method comprises separation of size fraction and casting process. The deposited sediment samples were wet sieved to separate the size fraction of >500 mum, (250-500) mum, (125-250) mum and (63-125) mum and settling procedures were followed for the separation of (40-63) mum, (20-40) mum, (10-20) mum and o C, ashed at 450 o C, respectively. In the casting process of sample, it was used polyester rapid cure resin and methyl ethyl ketone peroxide (MEKP) hardener. The moulded sediment sample was poured onto caster, allow for 60 hours long. The aim of this method is to get the casted sample which can be used effectively, efficiently and to be avoided from contamination of each other samples. Before casting, samples were grinded up to be fine. The result shows that casting product is ready to be used for natural radionuclide analysis

  10. New technique to take samples from environmental surfaces using flocked nylon swabs.

    Science.gov (United States)

    Hedin, G; Rynbäck, J; Loré, B

    2010-08-01

    Environmental surfaces near infected and/or colonised patients in hospitals are commonly contaminated with potentially pathogenic micro-organisms. At present, however, there is no standardised method for taking samples from surfaces in order to perform quantitative cultures. Usually contact plates or swabs are used, but these methods may give different results. The recovery rate of traditional swabbing, e.g. cotton or rayon, is poor. With a new type of swab utilising flocked nylon, the recovery may be enhanced up to three times compared with a rayon swab. In this study, we inoculated reference strains of Staphylococcus aureus and Enterococcus hirae onto a bedside table and took samples 1h later when inocula were dry. Sequential samples were taken from the same surface. A new sampling technique using two sequential nylon swabs for each sample was validated. The efficiency of the sampling, percentage recovery of the inoculum and the variation of culture results obtained from repeated experiments are described. Enhanced efficiency and higher recovery of inoculum were demonstrated using two sequential flocked nylon swabs for sampling. Copyright 2010 The Hospital Infection Society. Published by Elsevier Ltd. All rights reserved.

  11. Vibrio parahaemolyticus Strains of Pandemic Serotypes Identified from Clinical and Environmental Samples from Jiangsu, China

    Directory of Open Access Journals (Sweden)

    Jingjiao eLi

    2016-05-01

    Full Text Available Vibrio parahaemolyticus has emerged as a major foodborne pathogen in China, Japan, Thailand and other Asian countries. In this study, 72 strains of V. parahaemolyticus were isolated from clinical and environmental samples between 2006 and 2014 in Jiangsu, China. The serotypes and six virulence genes including thermostable direct hemolysin (TDR and TDR-related hemolysin (TRH genes were assessed among the isolates. Twenty five serotypes were identified and O3:K6 was one of the dominant serotypes. The genetic diversity was assessed by multilocus sequence typing (MLST analysis, and 48 sequence types (STs were found, suggesting this V. parahaemolyticus group is widely dispersed and undergoing rapid evolution. A total of 25 strains of pandemic serotypes such as O3:K6, O5:K17 and O1:KUT were identified. It is worth noting that the pandemic serotypes were not exclusively identified from clinical samples, rather, nine strains were also isolated from environmental samples; and some of these strains harbored several virulence genes, which may render those strains pathogenicity potential. Therefore, the emergence of these environmental pandemic V. parahaemolyticus strains may poses a new threat to the public health in China. Furthermore, six novel serotypes and 34 novel STs were identified among the 72 isolates, indicating that V. parahaemolyticus were widely distributed and fast evolving in the environment in Jiangsu, China. The findings of this study provide new insight into the phylogenic relationship between V. parahaemolyticus strains of pandemic serotypes from clinical and environmental sources and enhance the MLST database; and our proposed possible O- and K- antigen evolving paths of V. parahaemolyticus may help understand how the serotypes of this dispersed bacterial population evolve.

  12. Measuring environmental change in forest ecosystems by repeated soil sampling: a North American perspective

    Science.gov (United States)

    Lawrence, Gregory B.; Fernandez, Ivan J.; Richter, Daniel D.; Ross, Donald S.; Hazlett, Paul W.; Bailey, Scott W.; Oiumet, Rock; Warby, Richard A.F.; Johnson, Arthur H.; Lin, Henry; Kaste, James M.; Lapenis, Andrew G.; Sullivan, Timothy J.

    2013-01-01

    Environmental change is monitored in North America through repeated measurements of weather, stream and river flow, air and water quality, and most recently, soil properties. Some skepticism remains, however, about whether repeated soil sampling can effectively distinguish between temporal and spatial variability, and efforts to document soil change in forest ecosystems through repeated measurements are largely nascent and uncoordinated. In eastern North America, repeated soil sampling has begun to provide valuable information on environmental problems such as air pollution. This review synthesizes the current state of the science to further the development and use of soil resampling as an integral method for recording and understanding environmental change in forested settings. The origins of soil resampling reach back to the 19th century in England and Russia. The concepts and methodologies involved in forest soil resampling are reviewed and evaluated through a discussion of how temporal and spatial variability can be addressed with a variety of sampling approaches. Key resampling studies demonstrate the type of results that can be obtained through differing approaches. Ongoing, large-scale issues such as recovery from acidification, long-term N deposition, C sequestration, effects of climate change, impacts from invasive species, and the increasing intensification of soil management all warrant the use of soil resampling as an essential tool for environmental monitoring and assessment. Furthermore, with better awareness of the value of soil resampling, studies can be designed with a long-term perspective so that information can be efficiently obtained well into the future to address problems that have not yet surfaced.

  13. Use of aqueous slurries of coal fly ash samples for the direct determination of As, Sb, and Se by hydride generation-atomic fluorescence spectrometry

    Energy Technology Data Exchange (ETDEWEB)

    Moreda-Pineiro, J.; Moscoso-Perez, C.; Lopez-Mahia, P.; Muniategui-Lorenzoa, S.; Fernandez-Fernandez, E.; Prada-Rodriguez, D. [University of La Coruna, La Coruna (Spain). Faculty of Science

    2006-01-15

    A highly sensitive and simple method was developed based on the continuous hydride generation of aqueous coal fly ash slurry samples and the direct atomic fluorescence detection of As, Sb, and Se. A 2{sup 8} x 3/64 Plackett-Burman design was used as the multivariate strategy for evaluation of the effects of several variables involved in hydride generation efficiency (HCl, NaBH{sub 4}, NaBH{sub 4} flow rate, particle size, and slurry concentration). In addition, measurement time was also considered. Slurry concentration was the significant variable for As, hydrochloric acid concentration for Sb determination; no significant variable was found for Se. Optimum values for the significant variables were selected by using univariate approaches. The precision obtained ({lt} 8.0 %) was adequate for the determination of several hydride-forming elements in coal fly ash samples. Since there was a matrix effect, the standard addition method was required. Accuracy was assessed by analyzing NIST 1633b Coal Fly Ash certified reference material. Detection limits within the range of 0.03-0.67 {mu} g g{sup -1} were achieved. The developed methods were applied to several coal fly ash samples obtained from a coal-fired power plant.

  14. Forensic source differentiation of petrogenic, pyrogenic, and biogenic hydrocarbons in Canadian oil sands environmental samples.

    Science.gov (United States)

    Wang, Zhendi; Yang, C; Parrott, J L; Frank, R A; Yang, Z; Brown, C E; Hollebone, B P; Landriault, M; Fieldhouse, B; Liu, Y; Zhang, G; Hewitt, L M

    2014-04-30

    To facilitate monitoring efforts, a forensic chemical fingerprinting methodology has been applied to characterize and differentiate pyrogenic (combustion derived) and biogenic (organism derived) hydrocarbons from petrogenic (petroleum derived) hydrocarbons in environmental samples from the Canadian oil sands region. Between 2009 and 2012, hundreds of oil sands environmental samples including water (snowmelt water, river water, and tailings pond water) and sediments (from river beds and tailings ponds) have been analyzed. These samples were taken from sites where assessments of wild fish health, invertebrate communities, toxicology and detailed chemistry are being conducted as part of the Canada-Alberta Joint Oil Sands Monitoring Plan (JOSMP). This study describes the distribution patterns and potential sources of PAHs from these integrated JOSMP study sites, and findings will be linked to responses in laboratory bioassays and in wild organisms collected from these same sites. It was determined that hydrocarbons in Athabasca River sediments and waters were most likely from four sources: (1) petrogenic heavy oil sands bitumen; (2) biogenic compounds; (3) petrogenic hydrocarbons of other lighter fuel oils; and (4) pyrogenic PAHs. PAHs and biomarkers detected in snowmelt water samples collected near mining operations imply that these materials are derived from oil sands particulates (from open pit mines, stacks and coke piles). Crown Copyright © 2014. Published by Elsevier B.V. All rights reserved.

  15. Rapid separation of plutonium in environmental samples using an anion exchange resin disk

    International Nuclear Information System (INIS)

    Miura, T.; Oikawa, S.; Kishimoto, T.; Banba, S.; Morimoto, T.

    2001-01-01

    A rapid analytical method of Pu in environmental samples by alpha-ray spectrometry and high-resolution inductively coupled plasma mass spectrometer (HR-ICP-MS) using a 3M Empore TM anion exchange resin disk for solid phase extraction has been developed. A trace amount of Pu was quantitatively adsorbed with an Empore TM anion exchange resin disk (47 mm diam.) at a flow rate of 150-200 ml/min from 8 M HNO 3 sample solution. The disk was washed with 10 ml of 8 M HNO 3 and 12 ml of 9 M HCl and then the Pu was quantitatively eluted with 15 ml of 1 M HNO 3 /0.03 M ascorbic acid solution. The time needed to separate Pu from the sample solution with the present method was about 20 minutes. The separated Pu was determined with alpha-ray spectrometry and HR-ICP-MS. The method was applied to the determination of Pu in the certified reference material (IAEA-135) and the environmental soil sample. The analytical results were almost in good agreement with the literature values. (author)

  16. Application of environmental sampling to flexible endoscope reprocessing: the importance of monitoring the rinse water.

    Science.gov (United States)

    Muscarella, Lawrence F

    2002-05-01

    The routine sampling of environmental surfaces within a healthcare facility is generally not recommended by the Centers for Disease Control and Prevention (CDC), the Association for the Advancement of Medical Instrumentation (AAMI), and several other healthcare organizations. There are a few circumstances, however, for which some organizations do recommend this practice. For instance, the CDC and the Association for Professionals in Infection Control and Epidemiology (APIC) recommend environmental sampling as clinically required during an outbreak investigation. The CDC and AAMI also recommend routine sampling of the rinse water used during hemodialyzer (but not endoscope) reprocessing. The rationale for this recommendation is based in part on reports of pyrogenic responses, patient infections, and bacteremia due to waterborne, gram-negative bacteria during hemodialysis. To determine whether the basis for this rationale might similarly apply to the rinse water used during endoscope reprocessing, the Food and Drug Administration's medical device reporting database, the endoscope reprocessing literature, and other sources were reviewed. The results of this review indicate that nosocomial outbreaks linked to endoscopes contaminated with gram-negative bacteria have been frequently reported. As a result, for several reasons, including to minimize the risk of patient infection due to gram-negative bacteria following endoscopy, this article recommends routine microbiologic sampling of the rinse water used during endoscope reprocessing.

  17. Validation of the ANSR Listeria method for detection of Listeria spp. in environmental samples.

    Science.gov (United States)

    Wendorf, Michael; Feldpausch, Emily; Pinkava, Lisa; Luplow, Karen; Hosking, Edan; Norton, Paul; Biswas, Preetha; Mozola, Mark; Rice, Jennifer

    2013-01-01

    ANSR Listeria is a new diagnostic assay for detection of Listeria spp. in sponge or swab samples taken from a variety of environmental surfaces. The method is an isothermal nucleic acid amplification assay based on the nicking enzyme amplification reaction technology. Following single-step sample enrichment for 16-24 h, the assay is completed in 40 min, requiring only simple instrumentation. In inclusivity testing, 48 of 51 Listeria strains tested positive, with only the three strains of L. grayi producing negative results. Further investigation showed that L. grayi is reactive in the ANSR assay, but its ability to grow under the selective enrichment conditions used in the method is variable. In exclusivity testing, 32 species of non-Listeria, Gram-positive bacteria all produced negative ANSR assay results. Performance of the ANSR method was compared to that of the U.S. Department of Agriculture-Food Safety and Inspection Service reference culture procedure for detection of Listeria spp. in sponge or swab samples taken from inoculated stainless steel, plastic, ceramic tile, sealed concrete, and rubber surfaces. Data were analyzed using Chi-square and probability of detection models. Only one surface, stainless steel, showed a significant difference in performance between the methods, with the ANSR method producing more positive results. Results of internal trials were supported by findings from independent laboratory testing. The ANSR Listeria method can be used as an accurate, rapid, and simple alternative to standard culture methods for detection of Listeria spp. in environmental samples.

  18. In vitro assessment of Tribulus terrestris aqueous extract and Benzoxacin fraction against Helicobacter pylori isolates from biopsy samples of Iranian patients

    Directory of Open Access Journals (Sweden)

    Mojdeh Hakemi vala

    2014-02-01

    Full Text Available Background & Objectives:  Helicobacter pylori (Hp is related to gastritis, gastric ulcer, duodenal ulcer, and mucosal carcinoma. Emergence of multidrug resistant Hp strains encouraged the researchers to find new effective drugs. Especially medicinal herbs and plants which usually shows less side effects. The aim of this study was in vitro assessment of anti Hp activity of total extract of Tribulus terrestris (T. terrestris Benzoxacin, a local Iranian medicinal plant and its fraction Benzoxacin.Methods: total aqueous extract of aerial parts of the plant was prepared and liquid extraction with petroleum ether was used to separate its components. LC/MS system proved the existence of Benzoxazine derivative in the water fraction and the third's fraction. Anti (Hp effects of total extract and its third fraction were examined by cup plate method and using standard MacFarland. 50 biopsy samples of antrum were detected from patients who were endoscopic candidates in Milad and Fayazbakhsh  hospitals of Tehran during 2011. All samples were isolated, diagnosed based on standard methods and biochemical tests and confirmed by PCR method for ureC gene, too.  Different dilutions (250, 500,750 and 1000 mg/ml of total extract were prepared. Clarythromycin (Clr E-test strips and an identified Hp OC1096 was used, simultaneously.Results: Of 50 biopsy samples, 12 Hp strains were isolated. Rapid urease test were positive in all expect one biopsy sample. Existence of ureC gene in all isolates were confirmed expect one strain by PCR. By cup plate method, resistant to concentrations of 1000 and 750mg/ml were detected in 50% of Hp isolates and 66.6% of them were resistant to concentrations 250 and 500 mg/ml .Also, 83.3% of Hp strains were resistant to Benzoxacin fraction. Clarythromycin sensitivity detected in 83% of Hp isolates, simultaneously.Conclusion: This study was done as a pilot study for in vitro evaluation of antibacterial effect of total extract of T

  19. Development of the DNAA system for screening environmental samples to measure fissile material

    International Nuclear Information System (INIS)

    Ahn, Gil Hoon; Park, Il-Jin; Kim, J.G.; Min, Gyungsik; Kim, Sunha; Chung, Yongsam

    2008-01-01

    The DNAA system made up of pneumatic transport system, neutron detector assembly, and signal processing equipment was installed in the High-flux Advanced Neutron Application Reactor (HANARO). The optimized position of the detector in the delayed neutron counting (DNC) system was evaluated at a distance 15.1 cm from center of the DNC system with 18 He-3 detectors using MCNP simulation. The system shows excellent linearity from 0.67 ng to 713 ng U-235, and reproducibility of 1.26% standard deviation for the various mass groups of U-235 samples. The DNAA system shows detection efficiency of ∼30% and U-235 detection limit of 1ng. This system can be used on a screening method to assist the environmental sample analysis and to protect the clean room from elevated levels of fissile material that might be in routine samples. (author)

  20. A micro-fluidic sub-microliter sample introduction system for direct analysis of Chinese rice wine by inductively coupled plasma mass spectrometry using external aqueous calibration

    International Nuclear Information System (INIS)

    Cheng, Heyong; Liu, Jinhua; Xu, Zigang; Yin, Xuefeng

    2012-01-01

    A microfluidic sub-microliter sample introducing system was developed for direct analysis of Chinese rice wine by inductively coupled plasma mass spectrometry (ICP-MS). It consisted of a microfluidic chip integrating variable-volume sampling channels (0.1–0.8 μL), an eight-way multi-functional valve used in flow injection analysis (FIA), a syringe pump and a peristaltic pump of the Ar ICP-MS instrument. Three solutions, i.e., 15, 40 and 100 g L −1 glucose in 20% ethanol were used to simulate Chinese rice wine of the dry type, the semidry type and the semisweet type, each. The effects of their volume introduced into ICP-MS on the plasma stability and ICP-MS intensities were studied. The experimental results showed that neither alteration of plasma stability nor carbon deposition was observed when the sampling volume of 20% ethanol containing 100 g L −1 glucose was downscaled to 0.8 μL. Further reducing the sampling volume to 0.4 μL, no significant difference between the intensities of multi-element standard prepared in three simulated Chinese rice wine matrices and those in aqueous solution was observed. It indicated no negative effect of Chinese rice wine matrix on the ICP-MS intensities. A sampling volume of 0.4 μL was considered to be a good compromise between sensitivity and matrix effect. The flow rate of the carrier was chosen as 20 μL min −1 for obtaining peaks with the highest peak height within the shortest time. Based on these observations, a microflow injection (μFI) method for the direct determination of cadmium and lead in Chinese rice wine by ICP-MS using an external aqueous calibration was developed. The sample throughput was 45 h −1 with the detection limit of 19.8 and 10.4 ng L −1 for Cd and Pb, respectively. The contents of Cd and Pb in 10 Chinese rice wine samples were measured. The results agreed well with those determined by ICP-MS with the conventional sampling system after microwave assisted digestion. The recoveries of three

  1. A micro-fluidic sub-microliter sample introduction system for direct analysis of Chinese rice wine by inductively coupled plasma mass spectrometry using external aqueous calibration

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Heyong [Institute of Microanalytical Systems, Department of Chemistry, Zhejiang University, Hangzhou, 310027 (China); College of Material Chemistry and Chemical Engineering, Hangzhou Normal University, Hangzhou, 310036 (China); Liu, Jinhua [College of Material Chemistry and Chemical Engineering, Hangzhou Normal University, Hangzhou, 310036 (China); Xu, Zigang [Institute of Analytical and Applied Chemistry, Department of Chemistry, Zhejiang University, Hangzhou, 310027 (China); Yin, Xuefeng, E-mail: yinxf@zju.edu.cn [Institute of Microanalytical Systems, Department of Chemistry, Zhejiang University, Hangzhou, 310027 (China); College of Material Chemistry and Chemical Engineering, Hangzhou Normal University, Hangzhou, 310036 (China)

    2012-07-15

    A microfluidic sub-microliter sample introducing system was developed for direct analysis of Chinese rice wine by inductively coupled plasma mass spectrometry (ICP-MS). It consisted of a microfluidic chip integrating variable-volume sampling channels (0.1-0.8 {mu}L), an eight-way multi-functional valve used in flow injection analysis (FIA), a syringe pump and a peristaltic pump of the Ar ICP-MS instrument. Three solutions, i.e., 15, 40 and 100 g L{sup -1} glucose in 20% ethanol were used to simulate Chinese rice wine of the dry type, the semidry type and the semisweet type, each. The effects of their volume introduced into ICP-MS on the plasma stability and ICP-MS intensities were studied. The experimental results showed that neither alteration of plasma stability nor carbon deposition was observed when the sampling volume of 20% ethanol containing 100 g L{sup -1} glucose was downscaled to 0.8 {mu}L. Further reducing the sampling volume to 0.4 {mu}L, no significant difference between the intensities of multi-element standard prepared in three simulated Chinese rice wine matrices and those in aqueous solution was observed. It indicated no negative effect of Chinese rice wine matrix on the ICP-MS intensities. A sampling volume of 0.4 {mu}L was considered to be a good compromise between sensitivity and matrix effect. The flow rate of the carrier was chosen as 20 {mu}L min{sup -1} for obtaining peaks with the highest peak height within the shortest time. Based on these observations, a microflow injection ({mu}FI) method for the direct determination of cadmium and lead in Chinese rice wine by ICP-MS using an external aqueous calibration was developed. The sample throughput was 45 h{sup -1} with the detection limit of 19.8 and 10.4 ng L{sup -1} for Cd and Pb, respectively. The contents of Cd and Pb in 10 Chinese rice wine samples were measured. The results agreed well with those determined by ICP-MS with the conventional sampling system after microwave assisted digestion

  2. First detection of Mycobacterium ulcerans DNA in environmental samples from South America.

    Science.gov (United States)

    Morris, Aaron; Gozlan, Rodolphe; Marion, Estelle; Marsollier, Laurent; Andreou, Demetra; Sanhueza, Daniel; Ruffine, Rolland; Couppié, Pierre; Guégan, Jean-François

    2014-01-01

    The occurrences of many environmentally-persistent and zoonotic infections are driven by ecosystem changes, which in turn are underpinned by land-use modifications that alter the governance of pathogen, biodiversity and human interactions. Our current understanding of these ecological changes on disease emergence however remains limited. Buruli ulcer is an emerging human skin disease caused by the mycobacterium, Mycobacterium ulcerans, for which the exact route of infection remains unclear. It can have a devastating impact on its human host, causing extensive necrosis of the skin and underlying tissue, often leading to permanent disability. The mycobacterium is associated with tropical aquatic environments and incidences of the disease are significantly higher on floodplains and where there is an increase of human aquatic activities. Although the disease has been previously diagnosed in South America, until now the presence of M. ulcerans DNA in the wild has only been identified in Australia where there have been significant outbreaks and in western and central regions of Africa where the disease is persistent. Here for the first time, we have identified the presence of the aetiological agent's DNA in environmental samples from South America. The DNA was positively identified using Real-time Polymerase Chain Reaction (PCR) on 163 environmental samples, taken from 23 freshwater bodies in French Guiana (Southern America), using primers for both IS2404 and for the ketoreductase-B domain of the M. ulcerans mycolactone polyketide synthase genes (KR). Five samples out of 163 were positive for both primers from three different water bodies. A further nine sites had low levels of IS2404 close to a standard CT of 35 and could potentially harbour M. ulcerans. The majority of our positive samples (8/14) came from filtered water. These results also reveal the Sinnamary River as a potential source of infection to humans.

  3. First detection of Mycobacterium ulcerans DNA in environmental samples from South America.

    Directory of Open Access Journals (Sweden)

    Aaron Morris

    Full Text Available The occurrences of many environmentally-persistent and zoonotic infections are driven by ecosystem changes, which in turn are underpinned by land-use modifications that alter the governance of pathogen, biodiversity and human interactions. Our current understanding of these ecological changes on disease emergence however remains limited. Buruli ulcer is an emerging human skin disease caused by the mycobacterium, Mycobacterium ulcerans, for which the exact route of infection remains unclear. It can have a devastating impact on its human host, causing extensive necrosis of the skin and underlying tissue, often leading to permanent disability. The mycobacterium is associated with tropical aquatic environments and incidences of the disease are significantly higher on floodplains and where there is an increase of human aquatic activities. Although the disease has been previously diagnosed in South America, until now the presence of M. ulcerans DNA in the wild has only been identified in Australia where there have been significant outbreaks and in western and central regions of Africa where the disease is persistent. Here for the first time, we have identified the presence of the aetiological agent's DNA in environmental samples from South America. The DNA was positively identified using Real-time Polymerase Chain Reaction (PCR on 163 environmental samples, taken from 23 freshwater bodies in French Guiana (Southern America, using primers for both IS2404 and for the ketoreductase-B domain of the M. ulcerans mycolactone polyketide synthase genes (KR. Five samples out of 163 were positive for both primers from three different water bodies. A further nine sites had low levels of IS2404 close to a standard CT of 35 and could potentially harbour M. ulcerans. The majority of our positive samples (8/14 came from filtered water. These results also reveal the Sinnamary River as a potential source of infection to humans.

  4. Alpha spectroscopy with ionization chamber to determine uranium and thorium in environmental samples

    International Nuclear Information System (INIS)

    Carvalho Conti, L.F. de.

    1983-01-01

    A high-resolution, parallel Frisch ionization chamber with an efficient area of 320 cm 2 was developed and applied as an alpha spectrometer. The resolution of the spectrum is approximatelly 40 KeV fwhm (full width half maximum) for 233 U point source. The spectrum is recorded by a 1024 channels pulse-height analyser. The counting gas is commercial available mixture of argon and methane. The counting efficiency for 233 U energy-window selected is in order of 42% for a calibration source placed on the cathode axis. No radial dependence of this efficiency was observed. The chamber was used for counting the activity of uranium and thorium isotopes on large area stainless steel planchets. The large area thin sources were prepared extracting the uranium and thorium isotopes from 1M HNO 3 - aqueous solution with polymeric membranes containing tri-n-octyl-phosphine oxide adhered on the surface of the 314 cm 2 planchet. The integral back-ground is typically 7 counts/min between 4 and 6 MeV. The sensitivity of the procedure used ofr 238 U is about 30 Bq/1 based on 3S of back-ground, 1 liter sample volume and 30 min counting time. (Author) [pt

  5. Molecular diversity and distribution of marine fungi across 130 European environmental samples.

    Science.gov (United States)

    Richards, Thomas A; Leonard, Guy; Mahé, Frédéric; Del Campo, Javier; Romac, Sarah; Jones, Meredith D M; Maguire, Finlay; Dunthorn, Micah; De Vargas, Colomban; Massana, Ramon; Chambouvet, Aurélie

    2015-11-22

    Environmental DNA and culture-based analyses have suggested that fungi are present in low diversity and in low abundance in many marine environments, especially in the upper water column. Here, we use a dual approach involving high-throughput diversity tag sequencing from both DNA and RNA templates and fluorescent cell counts to evaluate the diversity and relative abundance of fungi across marine samples taken from six European near-shore sites. We removed very rare fungal operational taxonomic units (OTUs) selecting only OTUs recovered from multiple samples for a detailed analysis. This approach identified a set of 71 fungal 'OTU clusters' that account for 66% of all the sequences assigned to the Fungi. Phylogenetic analyses demonstrated that this diversity includes a significant number of chytrid-like lineages that had not been previously described, indicating that the marine environment encompasses a number of zoosporic fungi that are new to taxonomic inventories. Using the sequence datasets, we identified cases where fungal OTUs were sampled across multiple geographical sites and between different sampling depths. This was especially clear in one relatively abundant and diverse phylogroup tentatively named Novel Chytrid-Like-Clade 1 (NCLC1). For comparison, a subset of the water column samples was also investigated using fluorescent microscopy to examine the abundance of eukaryotes with chitin cell walls. Comparisons of relative abundance of RNA-derived fungal tag sequences and chitin cell-wall counts demonstrate that fungi constitute a low fraction of the eukaryotic community in these water column samples. Taken together, these results demonstrate the phylogenetic position and environmental distribution of 71 lineages, improving our understanding of the diversity and abundance of fungi in marine environments. © 2015 The Authors.

  6. Quality assurance and reference material requirements and considerations for environmental sample analysis in nuclear forensics

    International Nuclear Information System (INIS)

    Swindle, D.W. Jr.; Perrin, R.E.; Goldberg, S.A.; Cappis, J.

    2002-01-01

    Full text: High-sensitivity nuclear environmental sampling and analysis techniques have been proven in their ability to verify declared nuclear activities, as well as to assist in the detection of undeclared nuclear activities and facilities. Following the Gulf War, the capability and revealing power of environmental sampling and analysis techniques to support international safeguards was demonstrated and subsequently adopted by the International Atomic Energy Agency (IAEA) as routine safeguards measures in safeguards inspections and verifications. In addition to having been proved useful in international safeguards, environmental sampling and analysis techniques have demonstrated their utility in identifying the origins of 'orphaned' nuclear material, as well as the origin of intercepted smuggled nuclear material. Today, environmental sampling and analysis techniques are now being applied in six broad areas to support nonproliferation, disarmament treaty verification, national and international nuclear security, and environmental stewardship of weapons production activities. Consequently, more and more laboratories around the world are establishing capabilities or expanding capabilities to meet these growing applications, and as such requirements for quality assurance and control are increasing. The six areas are: 1) Nuclear safeguards; 2) Nuclear forensics/illicit trafficking; 3) Ongoing monitoring and verification (OMV); 4) Comprehensive Test Ban Treaty (CTBT); 5) Weapons dismantlement/materials disposition; and 6) Research and development (R and D)/environmental stewardship/safety. Application of environmental sampling and analysis techniques and resources to illicit nuclear material trafficking, while embodying the same basic techniques and resources, does have unique requirements for sample management, handling, protocols, chain of custody, archiving, and data interpretation. These requirements are derived from needs of how data from nuclear forensics

  7. The analysis of halogenated flame retardants by GC-HRMS in environmental samples.

    Science.gov (United States)

    Kolic, Terry M; Shen, Li; Macpherson, Karen; Fayez, Laila; Gobran, Teresa; Helm, Paul A; Marvin, Chris H; Arsenault, Gilles; Reiner, Eric J

    2009-01-01

    The analytical conditions required to determine polybrominated diphenylethers (PBDEs) and a variety of other halogenated flame retardants (HFRs) by gas chromatography-high resolution mass spectrometry (HRMS) in environmental samples are reported. HRMS can be used to analyze brominated diphenylethers (BDEs), 2,2',4,4',5,5'-hexabromobiphenyl (BB-153) as well as for a number of other emerging HFRs like allyl 2,4,6-tribromophenyl ether (ATE), 2-bromoallyl 2,4,6-tribromophenyl ether (BATE), 2,3-dibromopropyl 2,4,6-tribromophenyl ether (DPTE), octabromotrimethylphenylindane (OBIND), pentabromoethylbenzene (PBEB), hexabromobenzene (HBB), 1,2-bis (2,4,6-tribromophenoxy) ethane (BTBPE), decabromodiphenylethane (DBDPE), Dechlorane Plus (DP), hexachlorocyclopentadienyl-dibromocyclooctane (HCDBCO), tetrabromoethylcyclohexane (TBECH), 1,2,5,6-tetrabromocylcooctane (TBCO), 2-ethylhexyl-2,3,4,5-tetrabromobenzoate (EHTeBB), and bis(2-ethly-1-hexyl)tetrabromophthalate (BEHTBP). The detection in environmental matrices and use of these non-BDE flame retardants is reviewed. A method for the analysis of PBDEs by isotope dilution HRMS and 16 other halogenated compounds primarily used as flame retardants is reported. A survey of selected environmental samples, which included Lake Ontario surface and tributary sediments, municipal wastewater effluent, sludge, and mussel tissues, detected PBDEs, DP, DBDPE, BTBPE, PBEB, BB-153, and HBB.

  8. Dental microwear of sympatric rodent species sampled across habitats in southern Africa: Implications for environmental influence.

    Science.gov (United States)

    Burgman, Jenny H E; Leichliter, Jennifer; Avenant, Nico L; Ungar, Peter S

    2016-03-01

    Dental microwear textures have proven to be a valuable tool for reconstructing the diets of a wide assortment of fossil vertebrates. Nevertheless, some studies have recently questioned the efficacy of this approach, suggesting that aspects of habitat unrelated to food preference, especially environmental grit load, might have a confounding effect on microwear patterning that obscures the diet signal. Here we evaluate this hypothesis by examining microwear textures of 3 extant sympatric rodent species that vary in diet breadth and are found in a variety of habitat types: Mastomys coucha, Micaelamys namaquensis and Rhabdomys pumilio. We sample each of these species from 3 distinct environmental settings in southern Africa that differ in rainfall and vegetative cover: Nama-Karoo shrublands (semi-desert) and Dry Highveld grasslands in the Free State Province of South Africa, and Afromontane (wet) grasslands in the highlands of Lesotho. While differences between habitat types are evident for some of the species, inconsistency in the pattern suggests that the microwear signal is driven by variation in foods eaten rather than grit-level per se. It is clear that, at least for species and habitats sampled in the current study, environmental grit load does not swamp diet-related microwear signatures. © 2016 International Society of Zoological Sciences, Institute of Zoology/Chinese Academy of Sciences and John Wiley & Sons Australia, Ltd.

  9. Radiochemistry methods in DOE methods for evaluating environmental and waste management samples

    International Nuclear Information System (INIS)

    Fadeff, S.K.; Goheen, S.C.

    1994-08-01

    Current standard sources of radiochemistry methods are often inappropriate for use in evaluating US Department of Energy environmental and waste management (DOE/EW) samples. Examples of current sources include EPA, ASTM, Standard Methods for the Examination of Water and Wastewater and HASL-300. Applicability of these methods is limited to specific matrices (usually water), radiation levels (usually environmental levels), and analytes (limited number). Radiochemistry methods in DOE Methods for Evaluating Environmental and Waste Management Samples (DOE Methods) attempt to fill the applicability gap that exists between standard methods and those needed for DOE/EM activities. The Radiochemistry chapter in DOE Methods includes an ''analysis and reporting'' guidance section as well as radiochemistry methods. A basis for identifying the DOE/EM radiochemistry needs is discussed. Within this needs framework, the applicability of standard methods and targeted new methods is identified. Sources of new methods (consolidated methods from DOE laboratories and submissions from individuals) and the methods review process will be discussed. The processes involved in generating consolidated methods add editing individually submitted methods will be compared. DOE Methods is a living document and continues to expand by adding various kinds of methods. Radiochemistry methods are highlighted in this paper. DOE Methods is intended to be a resource for methods applicable to DOE/EM problems. Although it is intended to support DOE, the guidance and methods are not necessarily exclusive to DOE. The document is available at no cost through the Laboratory Management Division of DOE, Office of Technology Development

  10. Solar hydrogen from an aqueous, noble-metal-free hybrid system in a continuous-flow sampling reaction system.

    Science.gov (United States)

    Li, Xiaobo; Ward, Antony J; Masters, Anthony F; Maschmeyer, Thomas

    2014-06-10

    We introduce the visible-light photocatalytic H2 evolution reaction as catalyzed by a cobaloxime/carbon nitride (C3N4) noble-metal-free hybrid photosystem by using a continuous-flow sampling reaction system. The photocatalytic H2 evolution rate is highly dependent on the structure of C3N4, in which porous C3N4 shows the best activity compared with bulk C3N4 (lamellar) and C3N4 nanosheets. When using porous C3N4, the system is neither affected by the solution pH, nor the C3N4 concentration, nor the structure of the cobaloxime complex. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  11. Automated high-volume aerosol sampling station for environmental radiation monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Toivonen, H.; Honkamaa, T.; Ilander, T.; Leppaenen, A.; Nikkinen, M.; Poellaenen, R.; Ylaetalo, S

    1998-07-01

    An automated high-volume aerosol sampling station, known as CINDERELLA.STUK, for environmental radiation monitoring has been developed by the Radiation and Nuclear Safety Authority (STUK), Finland. The sample is collected on a glass fibre filter (attached into a cassette), the airflow through the filter is 800 m{sup 3}/h at maximum. During the sampling, the filter is continuously monitored with Na(I) scintillation detectors. After the sampling, the large filter is automatically cut into 15 pieces that form a small sample and after ageing, the pile of filter pieces is moved onto an HPGe detector. These actions are performed automatically by a robot. The system is operated at a duty cycle of 1 d sampling, 1 d decay and 1 d counting. Minimum detectable concentrations of radionuclides in air are typically 1Ae10 x 10{sup -6} Bq/m{sup 3}. The station is equipped with various sensors to reveal unauthorized admittance. These sensors can be monitored remotely in real time via Internet or telephone lines. The processes and operation of the station are monitored and partly controlled by computer. The present approach fulfils the requirements of CTBTO for aerosol monitoring. The concept suits well for nuclear material safeguards, too 10 refs.

  12. Long-term survival of Cryptococcus neoformans and Cryptococcus gattii in stored environmental samples from Colombia.

    Science.gov (United States)

    Escandón, Patricia; Castañeda, Elizabeth

    2015-01-01

    Both Cryptococcus neoformans and Cryptococcus gattii have been isolated from a variety of environmental sources in Colombia. To determine the viability of C. neoformans/C. gattii isolates in stored soil samples, filtrates and bird droppings from which these yeasts were previously recovered. A total of 964 samples collected between 2003 and 2009, and kept at room temperature were processed. From them, 653 samples were from trees decaying wood, 274 from soil filtrates and 37 from bird droppings. When C. neoformans or C. gattii were recovered, the molecular type of each isolate was established by PCR fingerprinting using the single primer (GTG)5. Among the processed samples, 161 isolates were recovered. From those, 81 (50.3%) corresponded to C. gattii recovered from decaying wood of Eucalyptus spp., Corymbia ficifolia, Terminalia catappa and Ficus spp. trees, and 80 (49.7%) corresponded to C. neoformans recovered from Ficus spp. and eucalyptus trees, as well as from bird droppings. The most prevalent molecular type among the C. gattii and C. neoformans isolates was VGII and VNI, respectively. The re-isolation of C. neoformans/C. gattii from 10-year stored samples suggests that these yeasts are able to keep viable in naturally colonized samples. Copyright © 2013 Revista Iberoamericana de Micología. Published by Elsevier Espana. All rights reserved.

  13. Measurement of the tritium concentration in the fractionated distillate from environmental water samples

    International Nuclear Information System (INIS)

    Atkinson, Robert; Eddy, Teresa; Kuhne, Wendy; Jannik, Tim; Brandl, Alexander

    2014-01-01

    Standard procedures for the measurement of tritium in water samples often require distillation of an appropriate sample aliquot. This distillation process may result in a fractionation of tritiated water and regular light water due to the vapor pressure isotope effect, introducing either a bias or an additional contribution to the total tritium measurement uncertainty. The current study investigates the relative change in vapor pressure isotope effect in the course of the distillation process, distinguishing it from and extending previously published measurements. The separation factor as a quantitative measure of the vapor pressure isotope effect is found to assume values of 1.04 ± 0.036, 1.05 ± 0.026, and 1.07 ± 0.038, depending on the vigor of the boiling process during distillation of the sample. A lower heat setting in the experimental setup, and therefore a less vigorous boiling process, results in a larger value for the separation factor. For a tritium measurement in water samples where the first 5 mL are discarded, the tritium concentration could be underestimated by 4–7%. - Highlights: • Tritium measurements in environmental water samples. • Distilled samples. • Vapor pressure isotope effect. • Depending on boiling mode. • Potential underestimate of tritium activity concentration of 4–7%

  14. Storing and accessing radioactivity data in environmental samples: the resources of GEORAD

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Tadeu A. de A.; Gonzalez, Sergio de A.; Reis, Rocio G. dos; Vasconcellos, Luiza M. de H. e; Lauria, Dejanira de C., E-mail: tedsilva@ird.gov.br, E-mail: gonzalez@ird.gov.br, E-mail: rocio@ird.gov.br, E-mail: luiza@ird.gov.br, E-mail: dejanira@ird.gov.br [Isntituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2013-07-01

    A georeferenced information system of radioactivity in environmental samples, named GEORAD, was created with the goal of aggregating, storing and promoting the preservation of the data produced by Brazilian researches, and sharing with the research community a database on radioactivity in Brazil. The system provides information on concentrations of the natural series, cosmogenic and fall out radionuclides in samples of soil, water and food, among others, along with the geographical location of the samples. By this way, the location of the sample can be visualized on Brazilian map. A spreadsheet containing all the data and information about the sample can be also obtained. As a result, the database system can enable the available data to be exploited to the maximum potential for further research and allows new research on existing information. The system also provides reference information on where the data information were obtained, that enables data citation and linking data with publications to increase visibility and accessibility of data and the research itself. The GEORAD system has been continuously fed and updated, containing, currently, data from more than 2,000 samples. This paper presents the latest system updates and discusses its resources. (author)

  15. Storing and accessing radioactivity data in environmental samples: the resources of GEORAD

    International Nuclear Information System (INIS)

    Silva, Tadeu A. de A.; Gonzalez, Sergio de A.; Reis, Rocio G. dos; Vasconcellos, Luiza M. de H. e; Lauria, Dejanira de C.

    2013-01-01

    A georeferenced information system of radioactivity in environmental samples, named GEORAD, was created with the goal of aggregating, storing and promoting the preservation of the data produced by Brazilian researches, and sharing with the research community a database on radioactivity in Brazil. The system provides information on concentrations of the natural series, cosmogenic and fall out radionuclides in samples of soil, water and food, among others, along with the geographical location of the samples. By this way, the location of the sample can be visualized on Brazilian map. A spreadsheet containing all the data and information about the sample can be also obtained. As a result, the database system can enable the available data to be exploited to the maximum potential for further research and allows new research on existing information. The system also provides reference information on where the data information were obtained, that enables data citation and linking data with publications to increase visibility and accessibility of data and the research itself. The GEORAD system has been continuously fed and updated, containing, currently, data from more than 2,000 samples. This paper presents the latest system updates and discusses its resources. (author)

  16. Environmental sampling and mud sampling program of CSDP (Continental Scientific Drilling Program) core hole VC-2B, Valles Caldera, New Mexico

    Energy Technology Data Exchange (ETDEWEB)

    Meeker, K.; Goff, F.; Gardner, J.N.; Trujillo, P.E.; Counce, D.

    1990-03-01

    An environmental sampling and drilling mud sampling program was conducted during the drilling operations of Continental Scientific Drilling Program (CSDP) core hole VC-2B, Valles caldera, New Mexico. A suite of four springs and creeks in the Sulphur Springs area were monitored on a regular basis to ensure that the VC-2B drilling program was having no environmental impact on water quality. In addition, a regional survey of springs in and around the Jemez Mountains was conducted to provide background data for the environmental monitoring. A drilling mud monitoring program was conducted during the operations to help identify major fluid entries in the core hole. 32 refs., 14 figs., 7 tabs.

  17. Direct detection of Mycobacterium ulcerans in clinical specimens and environmental samples.

    Science.gov (United States)

    Lavender, Caroline J; Fyfe, Janet A M

    2013-01-01

    Mycobacterium ulcerans is a slow-growing environmental bacterium that causes a severe skin disease known as Buruli ulcer. Rapid detection of M. ulcerans in clinical specimens is essential to ensure early diagnosis and prevention of disability. This chapter describes a real-time PCR method for the direct detection of M. ulcerans from swabs, fresh tissue biopsies, and fixed tissue sections, which are the most common types of specimens used in the diagnosis of Buruli ulcer. The chapter also briefly describes methods for PCR detection of M. ulcerans in environmental samples, as reliable detection of M. ulcerans in the environment is becoming increasingly important for understanding the ecology and transmission of this important pathogen.

  18. Toward a mathematical theory of environmental monitoring: the infrequent sampling problem

    International Nuclear Information System (INIS)

    Pimentel, K.D.

    1975-06-01

    Optimal monitoring of pollutants in diffusive environmental media was studied in the contexts of the subproblems of the optimal design and management of environmental monitors for bounds on maximum allowable errors in the estimate of the monitor state or output variables. Concise problem statements were made. Continuous-time finite-dimensional normal mode models for distributed stochastic diffusive pollutant transport were developed. The resultant set of state equations was discretized in time for implementation in the Kalman Filter in the problem of optimal state estimation. The main results of this thesis concern the special class of optimal monitoring problem called the infrequent sampling problem. Extensions to systems including pollutant scavenging and systems with emission or radiation boundary conditions were made. (U.S.)

  19. Middlesex Sampling Plant environmental report for calendar year 1989, Middlesex, New Jersey

    International Nuclear Information System (INIS)

    1990-05-01

    The environmental monitoring program, which began in 1980, was continued in 1989 at the former Middlesex Sampling Plant (MSP) site, located in the Borough of Middlesex, New Jersey. The MSP site is part of the Formerly Utilized Sites Remedial Action Program (FUSRAP), a Department of Energy (DOE) program to decontaminate or otherwise control sites where residual radioactive materials remain either from the early years of the nation's atomic energy program or from commercial operations causing conditions that Congress has authorized DOE to remedy. The monitoring program at MSP measures radon concentrations in air; external gamma radiation levels; and uranium and radium concentrations in surface water, groundwater, and sediment. Additionally, several nonradiological parameters are measured in groundwater samples. To verify that the site is in compliance with the DOE radiation protection standard (100 mrem/yr) and to assess its potential effect on public health, the radiation dose was calculated for a hypothetical maximally exposed individual. This report presents the findings of the environmental monitoring program conducted in the area of the Middlesex Sampling Plant (MSP) site during calendar year 1989. 17 refs., 16 figs., 16 tabs

  20. Isolation of new Brazilian giant viruses from environmental samples using a panel of protozoa.

    Science.gov (United States)

    Dornas, Fábio P; Khalil, Jacques Y B; Pagnier, Isabelle; Raoult, Didier; Abrahão, Jônatas; La Scola, Bernard

    2015-01-01

    The Megavirales are a newly described order capable of infecting different types of eukaryotic hosts. For the most part, the natural host is unknown. Several methods have been used to detect these viruses, with large discrepancies between molecular methods and co-cultures. To isolate giant viruses, we propose the use of different species of amoeba as a cellular support. The aim of this work was to isolate new Brazilian giant viruses by comparing the protozoa Acanthamoeba castellanii, A. polyphaga, A. griffini, and Vermamoeba vermiformis (VV) as a platform for cellular isolation using environmental samples. One hundred samples were collected from 3 different areas in September 2014 in the Pampulha lagoon of Belo Horizonte city, Minas Gerais, Brazil. PCR was used to identify the isolated viruses, along with hemacolor staining, labelling fluorescence and electron microscopy. A total of 69 viruses were isolated. The highest ratio of isolation was found in A. polyphaga (46.38%) and the lowest in VV (0%). Mimiviruses were the most frequently isolated. One Marseillevirus and one Pandoravirus were also isolated. With Brazilian environmental samples, we demonstrated the high rate of lineage A mimiviruses. This work demonstrates how these viruses survive and circulate in nature as well the differences between protozoa as a platform for cellular isolation.

  1. Speciation of Cr(VI) in environmental samples in the vicinity of the ferrochrome smelter

    International Nuclear Information System (INIS)

    Sedumedi, Hilda N.; Mandiwana, Khakhathi L.; Ngobeni, Prince; Panichev, Nikolay

    2009-01-01

    The impact of ferrochrome smelter on the contamination of its environment with toxic hexavalent chromium, Cr(VI), was assessed by analyzing smelter dusts, soil, grass and tree barks. For the separation of Cr(VI) from Cr(III), solid samples were treated with 0.1 M Na 2 CO 3 and filtered through hydrophilic PDVF 0.45 μm filter prior to the determination of Cr(VI) by electrothermal atomic absorption spectrometry (ET-AAS). Ferrochrome smelter dust was found to contain significant levels of Cr(VI), viz. 43.5 μg g -1 (cyclone dust), 2710 μg g -1 (fine dust), and 7800 μg g -1 (slimes dust) which exceeded the maximum acceptable risk concentration (20 μg g -1 ). The concentration of Cr(VI) in environmental samples of grass (3.4 ± 0.2), soil (7.7 ± 0.2), and tree bark (11.8 ± 1.2) collected in the vicinity of the chrome smelter were higher as compared with the same kind of samples collected from uncontaminated area. The results of the investigation show that ferrochrome smelter is a source of environmental pollution with contamination factors of Cr(VI) ranging between 10 and 50.

  2. Speciation of Cr(VI) in environmental samples in the vicinity of the ferrochrome smelter.

    Science.gov (United States)

    Sedumedi, Hilda N; Mandiwana, Khakhathi L; Ngobeni, Prince; Panichev, Nikolay

    2009-12-30

    The impact of ferrochrome smelter on the contamination of its environment with toxic hexavalent chromium, Cr(VI), was assessed by analyzing smelter dusts, soil, grass and tree barks. For the separation of Cr(VI) from Cr(III), solid samples were treated with 0.1M Na(2)CO(3) and filtered through hydrophilic PDVF 0.45 microm filter prior to the determination of Cr(VI) by electrothermal atomic absorption spectrometry (ET-AAS). Ferrochrome smelter dust was found to contain significant levels of Cr(VI), viz. 43.5 microg g(-1) (cyclone dust), 2710 microg g(-1) (fine dust), and 7800 microg g(-1) (slimes dust) which exceeded the maximum acceptable risk concentration (20 microg g(-1)). The concentration of Cr(VI) in environmental samples of grass (3.4+/-0.2), soil (7.7+/-0.2), and tree bark (11.8+/-1.2) collected in the vicinity of the chrome smelter were higher as compared with the same kind of samples collected from uncontaminated area. The results of the investigation show that ferrochrome smelter is a source of environmental pollution with contamination factors of Cr(VI) ranging between 10 and 50.

  3. An improved method for the analysis of volatile polyfluorinated alkyl substances in environmental air samples

    Energy Technology Data Exchange (ETDEWEB)

    Jahnke, Annika; Ahrens, Lutz [Institute for Coastal Research, GKSS Research Centre, Department of Environmental Chemistry, Geesthacht (Germany); University of Lueneburg, Institute for Ecology and Environmental Chemistry, Faculty of Environmental Sciences, Lueneburg (Germany); Ebinghaus, Ralf; Temme, Christian [Institute for Coastal Research, GKSS Research Centre, Department of Environmental Chemistry, Geesthacht (Germany); Berger, Urs [Norwegian Institute for Air Research (NILU), Polar Environmental Centre, Tromsoe (Norway); Stockholm University, Department of Applied Environmental Science (ITM), Stockholm (Sweden); Barber, Jonathan L. [Lancaster University, Department of Environmental Science, Faculty of Science and Technology, Lancaster (United Kingdom)

    2007-02-15

    This article describes the optimisation and validation of an analytical method for the determination of volatile polyfluorinated alkyl substances (PFAS) in environmental air samples. Airborne fluorinated telomer alcohols (FTOHs) as well as fluorinated sulfonamides and sulfonamidoethanols (FOSAs/FOSEs) were enriched on glass-fibre filters (GFFs), polyurethane foams (PUFs) and XAD-2 resin by means of high-volume air samplers. Sensitive and selective determination was performed using gas chromatography/chemical ionisation-mass spectrometry (GC/CI-MS). Five mass-labelled internal standard (IS) compounds were applied to ensure the accuracy of the analytical results. No major blank problems were encountered. Recovery experiments were performed, showing losses of the most volatile compounds during extraction and extract concentration as well as strong signal enhancement for FOSEs due to matrix effects. Breakthrough experiments revealed losses of the most volatile FTOHs during sampling, while FOSAs/FOSEs were quantitatively retained. Both analyte losses and matrix effects could be remediated by application of adequate mass-labelled IS. Method quantification limits (MQLs) of the optimised method ranged from 0.2 to 2.5 pg/m{sup 3} for individual target compounds. As part of the method validation, an interlaboratory comparison of instrumental quantification methods was conducted. The applicability of the method was demonstrated by means of environmental air samples from an urban and a rural location in Northern Germany. (orig.)

  4. New Brazilian giant viruses isolation from environmental samples using a panel of protozoa.

    Directory of Open Access Journals (Sweden)

    Fábio Pio Dornas

    2015-10-01

    Full Text Available The Megavirales are a newly described order capable of infecting different types of eukaryotic hosts. For the most part, the natural host is unknown. Several methods have been used to detect these viruses, with large discrepancies between molecular methods and co-cultures. To isolate giant viruses, we propose the use of different species of amoeba as a cellular support. The aim of this work was to isolate new Brazilian giant viruses by comparing the protozoa Acanthamoeba castellanii, A. polyphaga, A. griffini and Vermamoeba vermiformis as a platform for cellular isolation using environmental samples. One hundred samples were collected from 3 different areas in September 2014 in the Pampulha lagoon of Belo Horizonte city, Minas Gerais, Brazil. PCR was used to identify the isolated viruses, along with hemacolor staining, labelling fluorescence and electron microscopy. A total of 69 viruses were isolated. The highest ratio of isolation was found in Acanthamoeba polyphaga (46.38% and the lowest in Vermamoeba vermiformis (0%. Mimiviruses were the most frequently isolated. One Marseillevirus and one Pandoravirus were also isolated. With Brazilian environmental samples, we demonstrated the high rate of lineage A mimiviruses. This work demonstrates how these viruses survive and circulate in nature as well the differences between protozoa as a platform for cellular isolation.

  5. Standardization of Compton suppression gamma spectrometry system for the measurement of 129I in environmental samples

    International Nuclear Information System (INIS)

    Baburajan, A.; Sudheendran, V.; Dalvi, Sushant S.; Ravi, P.M.; Tripathi, R.M.

    2014-01-01

    This paper presents the results of standardization of a Compton Suppression Gamma spectrometry system for the determination of 129 I in various environmental samples in the pathways of Air - grass - milk (thyroid) - Man. The Compton Suppression System consists of an HPGe detector surrounded by an assembly of NaI(Tl) detectors, used to reduce the contribution of scattered gamma rays in the gamma spectrum that originate within the HPGe detector. A Compton suppression system consisting of N-type HPGe detector, 50% relative efficiency having low window thickness of about 0.3μm of Boron, and NaI(TI) detector as Compton shield was commissioned at ESL, Tarapur and various performance parameters were evaluated and documented. Being a reverse electrode HPGe system with low window thickness it can be used for the detection of low energy gamma lines from 3.0 keV to >10 MeV (Ortec). Hence, it is proposed to use the system for the determination of 129 I in environmental samples. The paper deals with the standardization of the system for efficiency and Minimum Detectable Activity (MDA) for various sample geometries in the detection of low level 129 I in various pathways of its exposure

  6. Analytical methods for the endocrine disruptor compounds determination in environmental water samples.

    Science.gov (United States)

    Locatelli, Marcello; Sciascia, Francesco; Cifelli, Roberta; Malatesta, Luciano; Bruni, Pantaleone; Croce, Fausto

    2016-02-19

    The potential risk of exposure to different xenobiotics, which can modulate the endocrine system and represent a treat for the wellness of an increasing number of people, has recently drawn the attention of international environmental and health agencies. Several agents, characterized by structural diversity, may interfer with the normal endocrine functions that regulate cell growth, homeostasis and development. Substances such as pesticides, herbicides, plasticizers, metals, etc. having endocrine activity (EDCs) are used in agriculture and industry and are also used as drugs for humans and animals. A difficulty in the analytical determination of these substances is the complexity of the matrix in which they are present. In fact, the samples most frequently analyzed consist of groundwater and surface water, including influent and effluent of wastewater treatment plants and drinking water. In this review, several sample pretreatment protocols, assays and different instrumental techniques recently used in the EDCs determination have been considered. This review concludes with a paragraph in which the most recent hyphenated-instrument techniques are treated, highlighting their sensitivity and selectivity for the analyses of environmental water samples. Copyright © 2016 Elsevier B.V. All rights reserved.

  7. Highly efficient detection of paclobutrazol in environmental water and soil samples by time-resolved fluoroimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Zhenjiang, E-mail: lzj1984@ujs.edu.cn [School of the Environment and Safety Engineering, Jiangsu University, Zhenjiang 212013 (China); Wei, Xi [School of the Environment and Safety Engineering, Jiangsu University, Zhenjiang 212013 (China); The Affiliated First People' s Hospital of Jiangsu University, Zhenjiang 212002 (China); Ren, Kewei; Zhu, Gangbing; Zhang, Zhen; Wang, Jiagao; Du, Daolin [School of the Environment and Safety Engineering, Jiangsu University, Zhenjiang 212013 (China)

    2016-11-01

    A fast and ultrasensitive indirect competitive time-resolved fluoroimmunoassay (TRFIA) was developed for the analysis of paclobutrazol in environmental water and soil samples. Paclobutrazol hapten was synthesized and conjugated to bovine serum albumin (BSA) for producing polyclonal antibodies. Under optimal conditions, the 50% inhibitory concentration (IC{sub 50} value) and limit of detection (LOD, IC{sub 20} value) were 1.09 μg L{sup −} {sup 1} and 0.067 μg L{sup −} {sup 1}, respectively. The LOD of TRFIA was improved 30-fold compared to the already reported ELISA. There was almost no cross-reactivity of the antibody with the other structural analogues of triazole compounds, indicating that the antibody had high specificity. The average recoveries from spiked samples were in the range from 80.2% to 104.7% with a relative standard deviation of 1.0–9.5%. The TRFIA results for the real samples were in good agreement with that obtained by high-performance liquid chromatography analyses. The results indicate that the established TRFIA has potential application for screening paclobutrazol in environmental samples. - Highlights: • The approach to design and synthesize the PBZ hapten was more straightforward. • A rapid and ultrasensitive TRFIA was developed and applied to the screening of PBZ. • The TRFIA for real soil samples showed reliability and high correlation with HPLC. • The PBZ TRFIA showed high sensitivity, simple operation, a wide range of quantitative analyses and no radioactive hazards.

  8. Establishing adequate conditions for mercury determination in environmental samples by INAA

    International Nuclear Information System (INIS)

    Perez, Caroline; Santos, Eliane C.; Saiki, Mitiko

    2017-01-01

    Mercury (Hg) is a toxic element released into the environment mainly by anthropic activities. Consequently, the improvement for Hg determination in environmental samples is of great interest. Instrumental Neutron Activation Analysis (INAA) is considered an adequate method to determine several elements. However, Hg determination by INAA is often hampered by its volatility, which causes losses. The aim of this study was to establish adequate irradiation conditions for Hg determination in environmental samples by INAA. The following parameters were evaluated: irradiation time, container for irradiation and spectral gamma ray interferences. For the study, aliquots of certified reference materials (CRMs) and tree bark samples were irradiated together with Hg synthetic standard at the IEA-R1 nuclear research reactor. Gamma ray activities of 1 97 Hg and 203 Hg were measured in a spectrometer coupled to a HGe detector. Results obtained indicated that polyethylene capsules or envelopes can be used as container for sample irradiation and the Hg impurities in these containers were negligible. Irradiation time of one hour was adequate for Hg determination and in long irradiations of 8 h problems of spectral interference of 198 Au and 75 Se were observed. In addition, Hg loss during the irradiation of 1 h and after irradiation was not observed. Quality control of Hg results, obtained in the CRMs analyses using one hour of irradiation, indicated good precision and accuracy with |Z score| < 2. The experimental conditions established in this study were applied to tree bark samples. Detection limits for Hg of these analyses were between 0.14 and 1.9 μg g -1 . (author)

  9. Recovery efficiency and limit of detection of aerosolized Bacillus anthracis Sterne from environmental surface samples.

    Science.gov (United States)

    Estill, Cheryl Fairfield; Baron, Paul A; Beard, Jeremy K; Hein, Misty J; Larsen, Lloyd D; Rose, Laura; Schaefer, Frank W; Noble-Wang, Judith; Hodges, Lisa; Lindquist, H D Alan; Deye, Gregory J; Arduino, Matthew J

    2009-07-01

    After the 2001 anthrax incidents, surface sampling techniques for biological agents were found to be inadequately validated, especially at low surface loadings. We aerosolized Bacillus anthracis Sterne spores within a chamber to achieve very low surface loading (ca. 3, 30, and 200 CFU per 100 cm(2)). Steel and carpet coupons seeded in the chamber were sampled with swab (103 cm(2)) or wipe or vacuum (929 cm(2)) surface sampling methods and analyzed at three laboratories. Agar settle plates (60 cm(2)) were the reference for determining recovery efficiency (RE). The minimum estimated surface concentrations to achieve a 95% response rate based on probit regression were 190, 15, and 44 CFU/100 cm(2) for sampling steel surfaces and 40, 9.2, and 28 CFU/100 cm(2) for sampling carpet surfaces with swab, wipe, and vacuum methods, respectively; however, these results should be cautiously interpreted because of high observed variability. Mean REs at the highest surface loading were 5.0%, 18%, and 3.7% on steel and 12%, 23%, and 4.7% on carpet for the swab, wipe, and vacuum methods, respectively. Precision (coefficient of variation) was poor at the lower surface concentrations but improved with increasing surface concentration. The best precision was obtained with wipe samples on carpet, achieving 38% at the highest surface concentration. The wipe sampling method detected B. anthracis at lower estimated surface concentrations and had higher RE and better precision than the other methods. These results may guide investigators to more meaningfully conduct environmental sampling, quantify contamination levels, and conduct risk assessment for humans.

  10. Recovery Efficiency and Limit of Detection of Aerosolized Bacillus anthracis Sterne from Environmental Surface Samples

    Science.gov (United States)

    Estill, Cheryl Fairfield; Baron, Paul A.; Beard, Jeremy K.; Hein, Misty J.; Larsen, Lloyd D.; Rose, Laura; Schaefer, Frank W.; Noble-Wang, Judith; Hodges, Lisa; Lindquist, H. D. Alan; Deye, Gregory J.; Arduino, Matthew J.

    2009-01-01

    After the 2001 anthrax incidents, surface sampling techniques for biological agents were found to be inadequately validated, especially at low surface loadings. We aerosolized Bacillus anthracis Sterne spores within a chamber to achieve very low surface loading (ca. 3, 30, and 200 CFU per 100 cm2). Steel and carpet coupons seeded in the chamber were sampled with swab (103 cm2) or wipe or vacuum (929 cm2) surface sampling methods and analyzed at three laboratories. Agar settle plates (60 cm2) were the reference for determining recovery efficiency (RE). The minimum estimated surface concentrations to achieve a 95% response rate based on probit regression were 190, 15, and 44 CFU/100 cm2 for sampling steel surfaces and 40, 9.2, and 28 CFU/100 cm2 for sampling carpet surfaces with swab, wipe, and vacuum methods, respectively; however, these results should be cautiously interpreted because of high observed variability. Mean REs at the highest surface loading were 5.0%, 18%, and 3.7% on steel and 12%, 23%, and 4.7% on carpet for the swab, wipe, and vacuum methods, respectively. Precision (coefficient of variation) was poor at the lower surface concentrations but improved with increasing surface concentration. The best precision was obtained with wipe samples on carpet, achieving 38% at the highest surface concentration. The wipe sampling method detected B. anthracis at lower estimated surface concentrations and had higher RE and better precision than the other methods. These results may guide investigators to more meaningfully conduct environmental sampling, quantify contamination levels, and conduct risk assessment for humans. PMID:19429546

  11. Photodegradation behaviour of sethoxydim and its comercial formulation Poast®under environmentally-relevant conditions in aqueous media. Study of photoproducts and their toxicity.

    Science.gov (United States)

    Sevilla-Morán, Beatriz; Calvo, Luisa; López-Goti, Carmen; Alonso-Prados, José L; Sandín-España, Pilar

    2017-02-01

    Photolysis is an important route for the abiotic degradation of many pesticides. However, the knowledge of the photolytic behaviour of these compounds and their commercial formulations under environmentally-relevant conditions are limited. The present study investigated the importance of photochemical processes on the persistence and fate of the herbicide sethoxydim and its commercial formulation Poast ® in aqueous media. Moreover, the effect of important natural water substances (nitrate, calcium, and ferric ions) on the photolysis of the herbicide was also studied. The results showed that additives existing in the commercial formulation Poast ® accelerated the rate of photolysis of sethoxydim by a factor of 3. On the contrary, the presence of nitrate and calcium ions had no effect on the photodegradation rate while ferric ions resulted in an important decrease in the half-life of sethoxydim possibly due to the formation of a complex. Different transformation products were identified in the course of sethoxydim irradiation and the effect of experimental conditions on their concentrations was investigated. Finally, Microtox ® test revealed that aqueous solutions of sethoxydim photoproducts increased the toxicity to the bacteria Vibrio fischeri. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Metagenomic covariation along densely sampled environmental gradients in the Red Sea

    KAUST Repository

    Thompson, Luke R

    2016-07-15

    Oceanic microbial diversity covaries with physicochemical parameters. Temperature, for example, explains approximately half of global variation in surface taxonomic abundance. It is unknown, however, whether covariation patterns hold over narrower parameter gradients and spatial scales, and extending to mesopelagic depths. We collected and sequenced 45 epipelagic and mesopelagic microbial metagenomes on a meridional transect through the eastern Red Sea. We asked which environmental parameters explain the most variation in relative abundances of taxonomic groups, gene ortholog groups, and pathways—at a spatial scale of <2000 km, along narrow but well-defined latitudinal and depth-dependent gradients. We also asked how microbes are adapted to gradients and extremes in irradiance, temperature, salinity, and nutrients, examining the responses of individual gene ortholog groups to these parameters. Functional and taxonomic metrics were equally well explained (75–79%) by environmental parameters. However, only functional and not taxonomic covariation patterns were conserved when comparing with an intruding water mass with different physicochemical properties. Temperature explained the most variation in each metric, followed by nitrate, chlorophyll, phosphate, and salinity. That nitrate explained more variation than phosphate suggested nitrogen limitation, consistent with low surface N:P ratios. Covariation of gene ortholog groups with environmental parameters revealed patterns of functional adaptation to the challenging Red Sea environment: high irradiance, temperature, salinity, and low nutrients. Nutrient-acquisition gene ortholog groups were anti-correlated with concentrations of their respective nutrient species, recapturing trends previously observed across much larger distances and environmental gradients. This dataset of metagenomic covariation along densely sampled environmental gradients includes online data exploration supplements, serving as a community

  13. Real-Time PCR Method for Detection of Salmonella spp. in Environmental Samples.

    Science.gov (United States)

    Kasturi, Kuppuswamy N; Drgon, Tomas

    2017-07-15

    The methods currently used for detecting Salmonella in environmental samples require 2 days to produce results and have limited sensitivity. Here, we describe the development and validation of a real-time PCR Salmonella screening method that produces results in 18 to 24 h. Primers and probes specific to the gene invA , group D, and Salmonella enterica serovar Enteritidis organisms were designed and evaluated for inclusivity and exclusivity using a panel of 329 Salmonella isolates representing 126 serovars and 22 non- Salmonella organisms. The invA - and group D-specific sets identified all the isolates accurately. The PCR method had 100% inclusivity and detected 1 to 2 copies of Salmonella DNA per reaction. Primers specific for Salmonella -differentiating fragment 1 (Sdf-1) in conjunction with the group D set had 100% inclusivity for 32 S Enteritidis isolates and 100% exclusivity for the 297 non-Enteritidis Salmonella isolates. Single-laboratory validation performed on 1,741 environmental samples demonstrated that the PCR method detected 55% more positives than the V itek i mmuno d iagnostic a ssay s ystem (VIDAS) method. The PCR results correlated well with the culture results, and the method did not report any false-negative results. The receiver operating characteristic (ROC) analysis documented excellent agreement between the results from the culture and PCR methods (area under the curve, 0.90; 95% confidence interval of 0.76 to 1.0) confirming the validity of the PCR method. IMPORTANCE This validated PCR method detects 55% more positives for Salmonella in half the time required for the reference method, VIDAS. The validated PCR method will help to strengthen public health efforts through rapid screening of Salmonella spp. in environmental samples.

  14. A simplified method for low-level tritium measurement in the environmental water samples

    International Nuclear Information System (INIS)

    Sakuma, Yoichi; Yamanishi, Hirokuni; Ogata, Yoshimune

    2004-01-01

    Low level liquid scintillation counting took much time with a lot of doing to distill off the impurities in the sample water before mixing the sample with the liquid scintillation cocktail. In the light of it, we investigated the possibility of an alternative filtration method for sample purification. The tritium concentration in the environmental water has become very low, and the samples have to be treated by electrolysis enrichment with a liquid scintillation analyzer. Using the solid polymer electrolyte enriching device, there is no need to add neither any electrolyte nor the neutralization after the concentration. If we could replace the distillation process with the filtration, the procedure would be simplified very much. We investigated the procedure and we were able to prove that the reverse osmosis (RO) filtration was available. Moreover, in order to rationalize all through the measurement method, we examined the followings: (1) Improvement of the enriching apparatus. (2) Easier measurement of heavy water concentration using a density meter, instead of a mass spectrometer. The concentration of water samples was measured to determine the enrichment rate of tritium during the electrolysis enrichment. (author)

  15. Round-robins in the area of uranium and plutonium bulk analysis of environmental samples

    International Nuclear Information System (INIS)

    Fabien Pointurier; Williams, R.W.; LaMont, S.P.; Steiner, R.E.; Bostick, D.A.; Olsen, K.B.; Wogman, N.A.

    2013-01-01

    In the framework of a collaboration between laboratories involved in bulk U and Pu analysis of environmental samples (DIF centre of the French Commissariat a l'Energie Atomique, US National Laboratories of New Brunswick, Lawrence Livermore, Pacific Northwest, Oak Ridge, and Los Alamos), two round-robins were organised, each one consisting of the complete analysis (chemical preparation and isotope measurement) of three Quality Control samples. The samples were 10 x 10 cm cotton tissues ('swipe samples') containing low amounts of U (from ∼20 to ∼150 ng) and Pu (from ∼0.15 to ∼10 pg). Despite using different spikes, different methods of sample preparation and different analytical instrumentation, the results for U and Pu contents and isotopic compositions reported by all laboratories are globally in good agreement. All laboratories are able to measure sub-pg amounts of U and Pu isotopes with acceptable accuracy and reproducibility, even if limited discrepancies are observed affecting one or other measurement and/or laboratory. General and laboratory specific recommendations were discussed and adopted to continue to improve the accuracy and precision of the measurements. (author)

  16. Calibration of a pixe set-up used in the analysis of environmental samples

    International Nuclear Information System (INIS)

    Calvelli, G.; Ceccato, D.; Mittner, P.; Schiavuta, E.; Bisceglie, V.; Giaretta, P.

    1985-01-01

    The use of a wide and homogeneous proton beam is a very useful feature in the analysis of environmental samples. We present a precise determination of the yield Y (z) = Nx/(Q . δ) (X counts . μC/sup -1/ . μg/sup -1/ . cm/sup 2/) vs z (the atomic number), for a PIXE set-up, with a wide proton beam at 1.8 MeV and for 11≤z≤53. We give both a satisfactory fit of the Y(z)'s with simple analytic functions and a comparison with a ''theoretical''yield computed with the published cross sections

  17. Application of solid phase extraction procedures for rare earth elements determination in environmental samples.

    Science.gov (United States)

    Pyrzynska, Krystyna; Kubiak, Anna; Wysocka, Irena

    2016-07-01

    Determination of rare earth elements in environmental samples requires often pre-concentration and separation step due to a low metal content and high concentration of the interfering matrix components. A solid phase extraction technique with different kind of solid sorbents offers a high enrichment factor, rapid phase separation and the possibility of its combination with various detection techniques used either in on-line or off-line mode. The recent developments in this area published over the last five years are presented and discussed in this paper. Copyright © 2016 Elsevier B.V. All rights reserved.

  18. Optimization of {sup 210}Po estimation in environmental samples using an improved deposition unit

    Energy Technology Data Exchange (ETDEWEB)

    Dubey, Jay Singh; Sahoo, Sunil Kumar; Mohapatra, Swagatika; Lenka, Pradyumna; Patra, Aditi Chakravarty; Thakur, Virender Kumar; Ravi, Pazhayath Mana; Tripathi, Raj Mangal [Bhabha Atomic Research Centre, Trombay, Mumbai (India). Health Physics Div.

    2015-06-01

    Measurement of {sup 210}Po in environmental matrices is important due to its very high specific activity, present in every compartment of the environment due to a daughter product of uranium ({sup 238}U), accumulative and highly toxic in nature. Conventional method for {sup 210}Po estimation is by auto-deposition onto both sides of a silver disc followed by alpha spectrometry of both the sides. A new deposition unit having the facility to hold the silver disc and magnetic stirring bar has designed and fabricated for {sup 210}Po estimation in which only one side is counted. In the conventional method, the total activity is distributed to the both sides of the silver disc and more counting time is required whereas in the improved deposition unit, only one side contain all the activity so that one time counting is required with better statistical significance. The same has been observed in spike recovery and water sample assessment. The tracer recovery in the conventional method was 72%-88% and 70%-85% whereas for the new deposition the recovery is 87%-99% and 78%-94% for spike recovery study and environmental samples, respectively. Certified tracers were analysed for the assurance of the reliability of the method and the results were in good agreement with the recommended value with a relative error <20%. The MDA of the method is 1.5 mBq for the estimation of {sup 210}Po at 3σ confidence level, 86400 s. counting time and 100 ml of water sample, taking the detector efficiency and chemical yield into consideration. The results obtained from both the methods were compared statistically. χ{sup 2} test, repeatability parameters, relative bias measurement and linearity test was performed for both the methods. The % difference between the two methods in terms of linearity is 0.2%. From the χ{sup 2} test it can be concluded that the measured data by two methods falls within 99% confidence interval. The modified deposition unit enhance the statistical significance, reduce

  19. Determination of Am-241, Cm-242 and Cm-244 in environmental samples

    International Nuclear Information System (INIS)

    Afsar, M.; Schuettelkopf, H.

    1988-01-01

    An analytical procedure for the determination of Am and Cm in environmental, liquid and gaseous effluent samples was developed. It is based on extraction chromatography with subsequent anion and cation exchange to remove matrix elements and to purify Am and Cm, which are then electrode posited from an oxalate/HCl medium. The mean value of the chemical yield is about 90%. A detection limit of 7 μBq/g is achieved. The decontamination factors for important α emitters are > 10 4 . Four analyses/week can be performed by one technician. (orig./RB) [de

  20. Determination of Organophosphorous Pesticides in Environmental Water Samples Using Surface-Engineered C18 Functionalized Silica-Coated Core-Shell Magnetic Nanoparticles-Based Extraction Coupled with GC-MS/MS Analysis.

    Science.gov (United States)

    Srivastava, Neha; Kumari, Supriya; Nair, Kishore; Alam, Samsul; Raza, Syed K

    2017-05-01

    The present paper depicts a novel method based on magnetic SPE (MSPE) for the determination of organophosphorus pesticides (OPs) such as phorate, malathion, and chlorpyrifos in environmental water samples. In this study, C18 functionalized silica-coated core-shell iron oxide magnetic nanoparticles (MNPs) were used as a surface-engineered magnetic sorbent for the selective extraction of pesticides from aqueous samples, followed by GC-MS and GC-tandem MS analysis for confirmative determination of the analytes. Various important method parameters, including quantity of MNP adsorbent, volume of sample, effective time for extraction, nature of the desorbing solvent, and pH of the aqueous sample, were investigated and optimized to obtain maximum method performance. Under the optimized instrumental analysis conditions, good linearity (r2 value ≥0.994) was achieved at the concentration range of 0.5-500 μg/L. Recoveries were in the range of 79.2-96.3 and 80.4-97.5% in selective-ion monitoring and multiple reaction monitoring (MRM) modes, respectively, at the spiking concentrations of 1, 5, and 10 μg/L. MRM mode showed better sensitivity, selectivity, and low-level detection (0.5 μg/L) of analytes. The novel MSPE method is a simple, cheap, rapid, and eco-friendly method for the determination of OPs in environmental water samples.

  1. Analytical Methodologies for the Determination of Endocrine Disrupting Compounds in Biological and Environmental Samples

    Directory of Open Access Journals (Sweden)

    Zoraida Sosa-Ferrera

    2013-01-01

    Full Text Available Endocrine-disruptor compounds (EDCs can mimic natural hormones and produce adverse effects in the endocrine functions by interacting with estrogen receptors. EDCs include both natural and synthetic chemicals, such as hormones, personal care products, surfactants, and flame retardants, among others. EDCs are characterised by their ubiquitous presence at trace-level concentrations and their wide diversity. Since the discovery of the adverse effects of these pollutants on wildlife and human health, analytical methods have been developed for their qualitative and quantitative determination. In particular, mass-based analytical methods show excellent sensitivity and precision for their quantification. This paper reviews recently published analytical methodologies for the sample preparation and for the determination of these compounds in different environmental and biological matrices by liquid chromatography coupled with mass spectrometry. The various sample preparation techniques are compared and discussed. In addition, recent developments and advances in this field are presented.

  2. Improved sample preparation method for environmental plutonium analysis by ICP-SFMS and alpha-spectrometry

    International Nuclear Information System (INIS)

    Varga, Z.; Stefanka, Z.; Suranyi, G.; Vajda, N.

    2007-01-01

    A rapid and simple sample preparation method for plutonium determination in environmental samples by inductively coupled plasma sector field mass spectrometry (ICP-SFMS) and alpha-spectrometry is described. The developed procedure involves a selective CaF 2 co-precipitation for preconcentration followed by extraction chromatographic separation. The proposed method effectively eliminates the possible interferences in mass spectrometric analysis and also removes interfering radionuclides that may disturb alpha-spectrometric measurement. For 239 Pu, 240 Pu and 241 Pu limits of detection of 9.0 fg x g -1 (0.021 mBq), 1.7 fg x g -1 (0.014 mBq) and 3.1 fg x g -1 (11.9 mBq) were achieved by ICP-SFMS, respectively, and 0.02 mBq by alpha-spectrometry. Results of certified reference materials agreed well with the recommended values. (author)

  3. Dynamic flow-through approaches for metal fractionation in environmentally relevant solid samples

    DEFF Research Database (Denmark)

    Miró, Manuel; Hansen, Elo Harald; Chomchoei, Roongrat

    2005-01-01

    In the recent decades, batchwise equilibrium-based single or sequential extraction schemes have been consolidated as analytical tools for fractionation analyses to assess the ecotoxicological significance of metal ions in solid environmental samples. However, taking into account that naturally...... generations of flow-injection analysis. Special attention is also paid to a novel, robust, non-invasive approach for on-site continuous sampling of soil solutions, capitalizing on flow-through microdialysis, which presents itself as an appealing complementary approach to the conventional lysimeter experiments....... In addition, a critical comparison between the time-resolved analytical information provided by these novel dynamic extraction procedures and that of the traditional schemes is given and thoroughly discussed in the bulk of the text....

  4. The application of extraction chromatography to the determination of radionuclides in biological and environmental samples

    International Nuclear Information System (INIS)

    Testa, C.; Delle Site, A.

    1976-01-01

    The paper describe the application of extraction chromatography to the determination of several alpha and beta emitters in biological and environmental samples. Both column extraction chromatography and batch extraction process have been used to isolate the radionuclides from the samples. The effect of several parameters (extractant concentration, support granulometry, stirring time, temperature, presence of a complexing agent) on the extraction and elution has been examined. The application of redox extraction chromatography is also described. A very simple and rapid determination of the activity retained on the column can be obtained by transferring the slurry to a counting vial and by adding the scintillation liquid for a direct detection of the α or β emission. The counting efficiencies obtained with this technique are compared with those obtained with ion exchange resins. The organic polymers used for the extraction chromatography give about 100% counting efficiency. The conventional ion exchange resin cannot be used to this purpose because of their strong light absorption. (T.G.)

  5. Automated Clean Chemistry for Bulk Analysis of Environmental Swipe Samples - FY17 Year End Report

    Energy Technology Data Exchange (ETDEWEB)

    Ticknor, Brian W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Metzger, Shalina C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); McBay, Eddy H. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hexel, Cole R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Tevepaugh, Kayron N. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Bostick, Debra A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-11-30

    Sample preparation methods for mass spectrometry are being automated using commercial-off-the-shelf (COTS) equipment to shorten lengthy and costly manual chemical purification procedures. This development addresses a serious need in the International Atomic Energy Agency’s Network of Analytical Laboratories (IAEA NWAL) to increase efficiency in the Bulk Analysis of Environmental Samples for Safeguards program with a method that allows unattended, overnight operation. In collaboration with Elemental Scientific Inc., the prepFAST-MC2 was designed based on COTS equipment. It was modified for uranium/plutonium separations using renewable columns packed with Eichrom TEVA and UTEVA resins, with a chemical separation method based on the Oak Ridge National Laboratory (ORNL) NWAL chemical procedure. The newly designed prepFAST-SR has had several upgrades compared with the original prepFAST-MC2. Both systems are currently installed in the Ultra-Trace Forensics Science Center at ORNL.

  6. Atmospheric pressure gas chromatography–time-of-flight-mass spectrometry (APGC–ToF-MS) for the determination of regulated and emerging contaminants in aqueous samples after stir bar sorptive extraction (SBSE)

    International Nuclear Information System (INIS)

    Pintado-Herrera, Marina G.; González-Mazo, Eduardo; Lara-Martín, Pablo A.

    2014-01-01

    Graphical abstract: Examples of identification of target (triclosan, TCS) and non-target (tributhyl phosphate, TBP) compounds in environmental water samples by APGC–ToF-MS. Some confirmation criteria are shown (i.e. mass spectra, isotopic distribution, and accurate mass). - Highlights: • 102 regulated and emerging contaminants are simultaneously extracted by SBSE. • APGC–ToF-MS is presented as an alternative to EI for the analysis of microcontaminants. • Identification of non-target compounds in environmental matrices is also explored. - Abstract: This work presents the development, optimization and validation of a multi-residue method for the simultaneous determination of 102 contaminants, including fragrances, UV filters, repellents, endocrine disruptors, biocides, polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), and several types of pesticides in aqueous matrices. Water samples were processed using stir bar sorptive extraction (SBSE) after the optimization of several parameters: agitation time, ionic strength, presence of organic modifiers, pH, and volume of the derivatizing agent. Target compounds were extracted from the bars by liquid desorption (LD). Separation, identification and quantification of analytes were carried out by gas chromatography (GC) coupled to time-of-flight (ToF-MS) mass spectrometry. A new ionization source, atmospheric pressure gas chromatography (APGC), was tested. The optimized protocol showed acceptable recovery percentages (50–100%) and limits of detection below 1 ng L −1 for most of the compounds. Occurrence of 21 out of 102 analytes was confirmed in several environmental aquatic matrices, including seawater, sewage effluent, river water and groundwater. Non-target compounds such as organophosphorus flame retardants were also identified in real samples by accurate mass measurement of their molecular ions using GC-APGC–ToF-MS. To the best of our knowledge, this is the first time that this

  7. Atmospheric pressure gas chromatography–time-of-flight-mass spectrometry (APGC–ToF-MS) for the determination of regulated and emerging contaminants in aqueous samples after stir bar sorptive extraction (SBSE)

    Energy Technology Data Exchange (ETDEWEB)

    Pintado-Herrera, Marina G.; González-Mazo, Eduardo; Lara-Martín, Pablo A., E-mail: pablo.lara@uca.es

    2014-12-03

    Graphical abstract: Examples of identification of target (triclosan, TCS) and non-target (tributhyl phosphate, TBP) compounds in environmental water samples by APGC–ToF-MS. Some confirmation criteria are shown (i.e. mass spectra, isotopic distribution, and accurate mass). - Highlights: • 102 regulated and emerging contaminants are simultaneously extracted by SBSE. • APGC–ToF-MS is presented as an alternative to EI for the analysis of microcontaminants. • Identification of non-target compounds in environmental matrices is also explored. - Abstract: This work presents the development, optimization and validation of a multi-residue method for the simultaneous determination of 102 contaminants, including fragrances, UV filters, repellents, endocrine disruptors, biocides, polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), and several types of pesticides in aqueous matrices. Water samples were processed using stir bar sorptive extraction (SBSE) after the optimization of several parameters: agitation time, ionic strength, presence of organic modifiers, pH, and volume of the derivatizing agent. Target compounds were extracted from the bars by liquid desorption (LD). Separation, identification and quantification of analytes were carried out by gas chromatography (GC) coupled to time-of-flight (ToF-MS) mass spectrometry. A new ionization source, atmospheric pressure gas chromatography (APGC), was tested. The optimized protocol showed acceptable recovery percentages (50–100%) and limits of detection below 1 ng L{sup −1} for most of the compounds. Occurrence of 21 out of 102 analytes was confirmed in several environmental aquatic matrices, including seawater, sewage effluent, river water and groundwater. Non-target compounds such as organophosphorus flame retardants were also identified in real samples by accurate mass measurement of their molecular ions using GC-APGC–ToF-MS. To the best of our knowledge, this is the first time that this

  8. Determination of Glucocorticoids in UPLC-MS in Environmental Samples from an Occupational Setting

    Directory of Open Access Journals (Sweden)

    Enrico Oddone

    2015-01-01

    Full Text Available Occupational exposures to glucocorticoids are still a neglected issue in some work environments, including pharmaceutical plants. We developed an analytical method to quantify simultaneously 21 glucocorticoids using UPLC coupled with mass spectrometry to provide a basis to carry out environmental monitoring. Samples were taken from air, hand-washing tests, pad-tests and wipe-tests. This paper reports the contents of the analytical methodology, along with the results of this extensive environmental and personal monitoring of glucocorticoids. The method in UPLC-MS turned out to be suitable and effective for the aim of the study. Wipe-test and pad-test desorption was carried out using 50 mL syringes, a simple technique that saves time without adversely affecting analyte recovery. Results showed a widespread environmental pollution due to glucocorticoids. This is of particular concern. Evaluation of the dose absorbed by each worker and identification of a biomarker for occupational exposure will contribute to assessment and prevention of occupational exposure.

  9. Micro-TLC Approach for Fast Screening of Environmental Samples Derived from Surface and Sewage Waters.

    Science.gov (United States)

    Zarzycki, Paweł K; Slączka, Magdalena M; Włodarczyk, Elżbieta; Baran, Michał J

    2013-01-01

    In this work we demonstrated analytical capability of micro-planar (micro-TLC) technique comprising one and two-dimensional (2D) separation modes to generate fingerprints of environmental samples originated from sewage and ecosystems waters. We showed that elaborated separation and detection protocols are complementary to previously invented HPLC method based on temperature-dependent inclusion chromatography and UV-DAD detection. Presented 1D and 2D micro-TLC chromatograms of SPE (solid-phase extraction) extracts were optimized for fast and low-cost screening of water samples collected from lakes and rivers located in the area of Middle Pomerania in northern part of Poland. Moreover, we studied highly organic compounds loaded in the treated and untreated sewage waters obtained from municipal wastewater treatment plant "Jamno" near Koszalin City (Poland). Analyzed environmental samples contained number of substances characterized by polarity range from estetrol to progesterone as well as chlorophyll-related dyes previously isolated and pre-purified by simple SPE protocol involving C18 cartridges. Optimization of micro-TLC separation and quantification protocols of such samples were discussed from the practical point of view using simple separation efficiency criteria including total peaks number, log(product Δ hR F ), signal intensity and peak asymmetry. Outcomes of the presented analytical approach, especially using detection involving direct fluorescence (UV366/Vis) and phosphomolybdic acid (PMA) visualization are compared with UV-DAD HPLC-generated data reported previously. Chemometric investigation based on principal components analysis revealed that SPE extracts separated by micro-TLC and detected under fluorescence and PMA visualization modes can be used for robust sample fingerprinting even after long-term storage of the extracts (up to 4 years) at subambient temperature (-20 °C). Such approach allows characterization of wide range of sample components

  10. Identification of Stenotrophomonas maltophilia strains isolated from environmental and clinical samples: a rapid and efficient procedure.

    Science.gov (United States)

    Pinot, C; Deredjian, A; Nazaret, S; Brothier, E; Cournoyer, B; Segonds, C; Favre-Bonté, S

    2011-11-01

    Aim of the study is to identify accurately Stenotrophomonas maltophilia isolates recovered from environmental and clinical samples. Recovery of Sten. maltophilia-like isolates from soil samples using the vancomycin, imipenem, amphotericin B (VIA) selective agar medium enabled distinction of various morphotype colonies. A set of soil and clinical isolates was tested for species identification using different methods. 16S rDNA analyses showed the dark green with a blue halo morphotype to be typical Sten. maltophilia strains. The API-20NE, Vitek-2 and Biolog phenotypic analyses typically used for the identification of clinical isolates did not perform well on these soil isolates. The species-specific PCR screening targeting Sten. maltophilia 23S rDNA and the multiplex smeD/ggpS PCR, differentiating Sten. maltophilia from Stenotrophomonas rhizophila, were tested for improvement of these identification schemes. The latter multiplex PCR identified all isolates tested in this study, whatever be their origin. Isolation on VIA medium and confirmation of Sten. maltophilia species membership by smeD PCR is proposed to identify environmental and clinical isolates of Sten. maltophilia. The proposed approach enables isolation and identification of Sten. maltophilia from different environments in an easy and rapid way. This approach will be useful to accurately manage studies on the abundance and distribution of Sten. maltophilia in hospital and nonhospital environments. © 2011 The Authors. Journal of Applied Microbiology © 2011 The Society for Applied Microbiology.

  11. Proteomic tools for environmental microbiology--a roadmap from sample preparation to protein identification and quantification.

    Science.gov (United States)

    Wöhlbrand, Lars; Trautwein, Kathleen; Rabus, Ralf

    2013-10-01

    The steadily increasing amount of (meta-)genomic sequence information of diverse organisms and habitats has a strong impact on research in microbial physiology and ecology. In-depth functional understanding of metabolic processes and overall physiological adaptation to environmental changes, however, requires application of proteomics, as the context specific proteome constitutes the true functional output of a cell. Considering the enormous structural and functional diversity of proteins, only rational combinations of various analytical approaches allow a holistic view on the overall state of the cell. Within the past decade, proteomic methods became increasingly accessible to microbiologists mainly due to the robustness of analytical methods (e.g. 2DE), and affordability of mass spectrometers and their relative ease of use. This review provides an overview on the complex portfolio of state-of-the-art proteomics and highlights the basic principles of key methods, ranging from sample preparation of laboratory or environmental samples, via protein/peptide separation (gel-based or gel-free) and different types of mass spectrometric protein/peptide analyses, to protein identification and abundance determination. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  12. A new selective enrichment procedure for isolating Pasteurella multocida from avian and environmental samples

    Science.gov (United States)

    Moore, M.K.; Cicnjak-Chubbs, L.; Gates, R.J.

    1994-01-01

    A selective enrichment procedure, using two new selective media, was developed to isolate Pasteurella multocida from wild birds and environmental samples. These media were developed by testing 15 selective agents with six isolates of P. multocida from wild avian origin and seven other bacteria representing genera frequently found in environmental and avian samples. The resulting media—Pasteurella multocida selective enrichment broth and Pasteurella multocida selective agar—consisted of a blood agar medium at pH 10 containing gentamicin, potassium tellurite, and amphotericin B. Media were tested to determine: 1) selectivity when attempting isolation from pond water and avian carcasses, 2) sensitivity for detection of low numbers of P. multocida from pure and mixed cultures, 3) host range specificity of the media, and 4) performance compared with standard blood agar. With the new selective enrichment procedure, P. multocida was isolated from inoculated (60 organisms/ml) pond water 84% of the time, whereas when standard blood agar was used, the recovery rate was 0%.

  13. New developments in the extraction and determination of parabens in cosmetics and environmental samples. A review.

    Science.gov (United States)

    Ocaña-González, Juan Antonio; Villar-Navarro, Mercedes; Ramos-Payán, María; Fernández-Torres, Rut; Bello-López, Miguel Angel

    2015-02-09

    Parabens are a family of synthetic esters of p-hydroxibenzoic acid widely used as preservatives in cosmetics and health-care products, among other daily-use commodities. Recently, their potential endocrine disrupting effects have raised concerns about their safety and their potential effects as emerging pollutants, leading to the regulation of the presence of parabens in commercial products by national and trans-national organizations. Also, this has led to an interest in developing sensible and reliable methods for their determination in environmental samples, cosmetics and health-care products. This paper is a comprehensive up-to-date review of the literature concerning the determination of parabens in environmental samples and cosmetic and health-care products. A brief revision of the literature concerning the traditional determination of parabens (1980-2003) is included, followed by an in-depth revision of the recent developments in both measurement and extraction methods for parabens in the last years (2003-2013). Finally, possible future perspectives in this field are proposed. Copyright © 2014 Elsevier B.V. All rights reserved.

  14. Reliability of environmental sampling culture results using the negative binomial intraclass correlation coefficient.

    Science.gov (United States)

    Aly, Sharif S; Zhao, Jianyang; Li, Ben; Jiang, Jiming

    2014-01-01

    The Intraclass Correlation Coefficient (ICC) is commonly used to estimate the similarity between quantitative measures obtained from different sources. Overdispersed data is traditionally transformed so that linear mixed model (LMM) based ICC can be estimated. A common transformation used is the natural logarithm. The reliability of environmental sampling of fecal slurry on freestall pens has been estimated for Mycobacterium avium subsp. paratuberculosis using the natural logarithm transformed culture results. Recently, the negative binomial ICC was defined based on a generalized linear mixed model for negative binomial distributed data. The current study reports on the negative binomial ICC estimate which includes fixed effects using culture results of environmental samples. Simulations using a wide variety of inputs and negative binomial distribution parameters (r; p) showed better performance of the new negative binomial ICC compared to the ICC based on LMM even when negative binomial data was logarithm, and square root transformed. A second comparison that targeted a wider range of ICC values showed that the mean of estimated ICC closely approximated the true ICC.

  15. Environmental samples analysis by Atomic Absorption Spectrophotometry and Inductively Coupled Plasma-Optical Emission Spectroscopy

    International Nuclear Information System (INIS)

    Popescu, I.V.; Iordan, M.; Stihi, C.; Bancuta, A.; Busuioc, G.; Dima, G.; Ciupina, V.; Belc, M.; Vlaicu, Gh.; Marian, R.

    2002-01-01

    Biological samples are interesting from many aspects of environmental monitoring. By analyzing tree leaves conclusions can be drown regarding the metal loading in the growth medium. So that, starting from assumption that the pollution factors from environmental medium can modify the normal concentration of elements, we decided to control the presence of toxic elements and the deviation from normal state of elements in leaves of different trees from areas situated at different distances of pollution source. The aim of this work is to determine the elemental composition of tree leaves using Atomic Absorption Spectrophotometry (AAS) method and Inductively Coupled Plasma-Optical Emission Spectroscopy (ICP-OES) method. Using AAS spectrophotometer SHIMADZU we identified and determined the concentration of: Cd, Co, Cu, Zn, Mn, Cr, Fe, Se, Pb with an instrumental error less than 1% for most of the elements analyzed. The same samples were analyzed by ICP-OES spectrometer, BAIRD ICP2070-Sequential Plasma spectrometer. We identified and determined in leaves of different trees the concentration of Mg, Ca, and Sr with a precision less than 6%. (authors)

  16. A novel approach to bar adsorptive microextraction: Cork as extractor phase for determination of benzophenone, triclocarban and parabens in aqueous samples.

    Science.gov (United States)

    Dias, Adriana Neves; da Silva, Ana Cristine; Simão, Vanessa; Merib, Josias; Carasek, Eduardo

    2015-08-12

    This study describes the use of cork as a new coating for bar adsorptive microextraction (BAμE) and its application in determining benzophenone, triclocarban and parabens in aqueous samples by HPLC-DAD. In this study bars with 7.5 and 15 mm of length were used. The extraction and liquid desorption steps for BAμE were optimized employing multivariate and univariate procedures. The desorption time and solvent used for liquid desorption were optimized by univariate and multivariate studies, respectively. For the extraction step the sample pH was optimized by univariate experiments while the parameters extraction time and ionic strength were evaluated using the Doehlert design. The optimum extraction conditions were sample pH 5.5, NaCl concentration 25% and extraction time 90 min. Liquid desorption was carried out for 30 min with 250 μL (bar length of 15 mm) or 100 μL (bar length of 7.5 mm) of ACN:MeOH (50:50, v/v). The quantification limits varied between 1.6 and 20 μg L(-1) (bar length of 15 mm) and 0.64 and 8 μg L(-1) (bar length of 7.5 mm). The linear correlation coefficients were higher than 0.98 for both bars. The method with 7.5 mm bar length showed recovery values between 65 and 123%. The bar-to-bar reproducibility and the repeatability were lower than 13% (n = 2) and 14% (n = 3), respectively. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. [Isolation of Sporothrix pallida complex in clinical and environmental samples from Chile].

    Science.gov (United States)

    Cruz Choappa, Rodrigo M; Vieille Oyarzo, Peggy I; Carvajal Silva, Laura C

    2014-01-01

    The isolation of S. pallida complex from medical samples and home garden soil of a patient in Chile is here in reported. Fungi of the Sporothrix schenckii complex can cause various infections. In Chile, the medical and environmental isolates of these this complex are rare. The aim of this study was to identify an unusual agent in a case of onychomycosis and to detect its presence in the patient's home garden. For this purpose, clinical samples were obtained by scraping the patient's subungueal first right toe nail as well as by taking soil samples from different areas of her home garden. Species identification was performed by morphophysiology and one of the strains isolated from the patient's toe nail was sent to CBS for molecular confirmation (14.062). S. pallida complex was identified both from the patient's toe nail and samples taken from her home garden. Copyright © 2014 Asociación Argentina de Microbiología. Publicado por Elsevier España. All rights reserved.

  18. Factors associated with Salmonella presence in environmental samples and bulk tank milk from US dairies.

    Science.gov (United States)

    Ruzante, J M; Lombard, J E; Wagner, B; Fossler, C P; Karns, J S; Van Kessel, J A S; Gardner, I A

    2010-12-01

    The objective of this study was to evaluate herd characteristics and management practices associated with presence of Salmonella in the farm environment and in bulk tank milk (BTM) in US dairy herds. Herd management data, environmental culture, BTM and in-line milk filter polymerase chain reaction results for Salmonella from 260 US dairy herds surveyed during the National Animal Health Monitoring System Dairy 2007 study were analysed. Herd characteristics and management practices were screened by univariate analysis, and selected variables were used to construct a logistic regression model to identify factors associated with the presence of Salmonella in environmental samples. To identify factors associated with the occurrence of Salmonella in BTM and milk filters, a priori selected variables that were related to milking procedures were analysed univariately and a logistic regression model was constructed. The presence of Salmonella in the farm environment was associated with location of the operation in the East (OR = 4.8; CI: 1.9-11.6), not using a broadcast manure spreader (OR = 3.2; CI: 1.4-7.5), use of bovine somatotropin (BST) (OR = 2.7; CI: 1.5-5.0) and use of anionic salts (OR = 2.2; CI: 1.2-3.9). In the final multivariable model, herds with fewer than 100 cows were at decreased odds (OR = 0.3; CI: 0.1-0.7) of being culture positive for Salmonella as were herds with between 100 and 499 cows (OR = 0.4; CI: 0.2-0.8) compared with herds having 500 or more cows. The presence of culture-positive environmental samples and herd size were significantly associated with Salmonella BTM contamination. The herd-level factors identified in this study were in agreement with prior studies but also identified other potential factors that can be targeted in Salmonella control programmes. © 2010 Blackwell Verlag GmbH.

  19. Preparation of Environmental and Food Samples to Support the Heavy Metals Detection by Stripping Electrochemical

    International Nuclear Information System (INIS)

    Iswani S

    2002-01-01

    Preparation of environmental and food samples to support the heavy metals detection by stripping electrochemistry was done. The water samples taken directly from the ground water were acidified with 1 mL of HNO 3 acic suprapure was not digested, while the soils samples which have already dried in the oven at 105 o C, ware grinded and sieved through 150 μm, werte digested with HNO 3 acic suprapure in the digestion bomb at 150 o C for 3-4 hours. The mussels samples which have already freezed in the freezer were peeled, dried with N 2 liquid, grinded and dried again in the freeze drier at the pressure of ≅ 10 -2 mBar, and then were grinded again, weighted, digested with HNO 3 acic and HClO 4 suprapure in the digestion bomb at 150 o C for 3 hours. Food samples were homogenized by electric mixer, dried with freeze dried, homogenized again by using ZrO 2 ball mill, weighted, digested by HPA (high Pressure Asher). The heavy metals in the food samples solution of digestion product were detected by using Polarographic Analyzer EGandG of SWV and DPASV methods, while in the water, soils and the mussels solution were detected by using PDV 2000 and Polarograf E-505, DPASV method. The method validity were tested with SRM materials such as soil-5, soil-7, water W-4, and coppepoda. The heavy metals detection results in the water, soils, mussels, and food by electrochemical method were reported in this paper. (author)

  20. The SAMPL5 challenge for embedded-cluster integral equation theory: solvation free energies, aqueous p$K_a$, and cyclohexane–water log D

    CERN Document Server

    Tielker, Nicolas; Heil, Jochen; Kloss, Thomas; Ehrhart, Sebastian; Güssregen, Stefan; Schmidt, K. Friedemann; Kast, Stefan M.

    2016-01-01

    We predict cyclohexane–water distribution coefficients (log D7.4) for drug-like molecules taken from the SAMPL5 blind prediction challenge by the “embedded cluster reference interaction site model” (EC-RISM) integral equation theory. This task involves the coupled problem of predicting both partition coefficients (log P) of neutral species between the solvents and aqueous acidity constants (pKa) in order to account for a change of protonation states. The first issue is addressed by calibrating an EC-RISM-based model for solvation free energies derived from the “Minnesota Solvation Database” (MNSOL) for both water and cyclohexane utilizing a correction based on the partial molar volume, yielding a root mean square error (RMSE) of 2.4 kcal mol−1 for water and 0.8–0.9 kcal mol−1 for cyclohexane depending on the parametrization. The second one is treated by employing on one hand an empirical pKa model (MoKa) and, on the other hand, an EC-RISM-derived regression of published acidity constants (RMSE...

  1. Analysis of anions in aqueous samples by ion chromatography and capillary electrophoresis. A comparative study of peak modeling and validation criteria.

    Science.gov (United States)

    Tamisier-Karolak, S L; Le Potier, I; Barlet, O; Czok, M

    1999-08-13

    The object of this study is the comparison of two methods for the quantitative analysis of anions in aqueous samples: ion chromatography with conductimetric detection, and capillary zone electrophoresis with indirect photometric detection. The comparison includes modeling of experimental peaks as well as statistical validation criteria according to the recommendations of the International Conference on Harmonisation. In ion chromatography, peak shapes are Gaussian or exponentially modified Gaussian, and the number of theoretical plates calculated using the appropriate mathematical relations correspond well to those obtained from statistical moments. Peaks in capillary electrophoresis, however, do not follow the same models. A different model, treating the peaks as right angle triangles, has been studied. Equations corresponding to this model permit a good estimation of plate numbers. The statistical validation of these methods includes detection limits, linearity, accuracy and precision. Overall, ion chromatography yields better validation results than capillary electrophoresis. In the latter method the injection mode plays an important role, with voltage injection giving lower detection limits than hydrodynamic injection.

  2. Methodologies for the Extraction of Phenolic Compounds from Environmental Samples: New Approaches

    Directory of Open Access Journals (Sweden)

    Cristina Mahugo Santana

    2009-01-01

    Full Text Available Phenolic derivatives are among the most important contaminants present in the environment. These compounds are used in several industrial processes to manufacture chemicals such as pesticides, explosives, drugs and dyes. They also are used in the bleaching process of paper manufacturing. Apart from these sources, phenolic compounds have substantial applications in agriculture as herbicides, insecticides and fungicides. However, phenolic compounds are not only generated by human activity, but they are also formed naturally, e.g., during the decomposition of leaves or wood. As a result of these applications, they are found in soils and sediments and this often leads to wastewater and ground water contamination. Owing to their high toxicity and persistence in the environment, both, the US Environmental Protection Agency (EPA and the European Union have included some of them in their lists of priority pollutants. Current standard methods of phenolic compounds analysis in water samples are based on liquid–liquid extraction (LLE while Soxhlet extraction is the most used technique for isolating phenols from solid matrices. However, these techniques require extensive cleanup procedures that are time-intensive and involve expensive and hazardous organic solvents, which are undesirable for health and disposal reasons. In the last years, the use of news methodologies such as solid-phase extraction (SPE and solid-phase microextraction (SPME have increased for the extraction of phenolic compounds from liquid samples. In the case of solid samples, microwave assisted extraction (MAE is demonstrated to be an efficient technique for the extraction of these compounds. In this work we review the developed methods in the extraction and determination of phenolic derivatives in different types of environmental matrices such as water, sediments and soils. Moreover, we present the new approach in the use of micellar media coupled with SPME process for the

  3. DEP-On-Go for Simultaneous Sensing of Multiple Heavy Metals Pollutants in Environmental Samples

    Directory of Open Access Journals (Sweden)

    Madhu Biyani

    2016-12-01

    Full Text Available We describe a simple and affordable “Disposable electrode printed (DEP-On-Go” sensing platform for the rapid on-site monitoring of trace heavy metal pollutants in environmental samples for early warning by developing a mobile electrochemical device composed of palm-sized potentiostat and disposable unmodified screen-printed electrode chips. We present the analytical performance of our device for the sensitive detection of major heavy metal ions, namely, mercury, cadmium, lead, arsenic, zinc, and copper with detection limits of 1.5, 2.6, 4.0, 5.0, 14.4, and, 15.5 μg·L−1, respectively. Importantly, the utility of this device is extended to detect multiple heavy metals simultaneously with well-defined voltammograms and similar sensitivity. Finally, “DEP-On-Go” was successfully applied to detect heavy metals in real environmental samples from groundwater, tap water, house dust, soil, and industry-processed rice and noodle foods. We evaluated the efficiency of this system with a linear correlation through inductively coupled plasma mass spectrometry, and the results suggested that this system can be reliable for on-site screening purposes. On-field applications using real samples of groundwater for drinking in the northern parts of India support the easy-to-detect, low-cost (<1 USD, rapid (within 5 min, and reliable detection limit (ppb levels performance of our device for the on-site detection and monitoring of multiple heavy metals in resource-limited settings.

  4. The aqueous chemistry of oxides

    CERN Document Server

    Bunker, Bruce C

    2016-01-01

    The Aqueous Chemistry of Oxides is a comprehensive reference volume and special topics textbook that explores all of the major chemical reactions that take place between oxides and aqueous solutions. The book highlights the enormous impact that oxide-water reactions have in advanced technologies, materials science, geochemistry, and environmental science.

  5. Rapid microsphere assay for identification of cryptosporidium hominis and cryptosporidium parvum in stool and environmental samples.

    Science.gov (United States)

    Bandyopadhyay, Kakali; Kellar, Kathryn L; Moura, Iaci; Casaqui Carollo, Maria Cristina; Graczyk, Thaddeus K; Slemenda, Susan; Johnston, Stephanie P; da Silva, Alexandre J

    2007-09-01

    Cryptosporidium hominis and Cryptosporidium parvum are associated with massive disease outbreaks worldwide. Because these two species have different transmission cycles, identification of these parasites to the species level in clinical samples may provide laboratory data of crucial importance in epidemiologic investigations. To date, the most reliable way to differentiate C. hominis and C. parvum is based on DNA sequencing analysis of PCR amplicons. Although this approach is very effective for differentiation of Cryptosporidium species, it is labor-intensive and time-consuming compared with methods that do not require DNA sequencing analysis as an additional step and that have been successfully used for specific identification of a number of pathogens. In this study, we describe a novel Luminex-based assay that can differentiate C. hominis from C. parvum in a rapid and cost-effective manner. The assay was validated by testing a total of 143 DNA samples extracted from clinical specimens, environmental samples, or samples artificially spiked with Cryptosporidium oocysts. As few as 10 oocysts per 300 microl of stools could be detected with this assay. The assay format includes species-specific probes linked to carboxylated Luminex microspheres that hybridize to a Cryptosporidium microsatellite-2 region (ML-2) where C. hominis and C. parvum differ by one nucleotide substitution. The assay proved to be 100% specific when samples that had been characterized by direct fluorescent antibody test (DFA) and DNA sequencing analysis were tested. In addition, the assay was more sensitive than DFA and provided species identification, which is an advantage for epidemiologic studies.

  6. Parabens in 24 h urine samples of the German Environmental Specimen Bank from 1995 to 2012.

    Science.gov (United States)

    Moos, Rebecca K; Koch, Holger M; Angerer, Jürgen; Apel, Petra; Schröter-Kermani, Christa; Brüning, Thomas; Kolossa-Gehring, Marike

    2015-10-01

    Parabens are widely used as antimicrobial preservatives in personal care and consumer products, food and pharmaceuticals. Due to their ubiquity, humans are constantly exposed to these chemicals. We assessed exposure to nine parabens (methyl-, ethyl-, n- and iso-propyl-, n- and iso-butyl-, benzyl-, pentyl- and heptyl paraben) in the German population from 1995 to 2012 based on 660 24h urine samples from the German Environmental Specimen Bank (ESB) using on-line HPLC coupled to isotope dilution tandem mass spectrometry. The limit of quantification (LOQ) was 0.5 μg/L for all parabens. We detected methyl-, ethyl- and n-propyl paraben in 79-99% of samples, followed by n-butyl paraben in 40% of samples. We infrequently detected iso-butyl-, iso-propyl- and benzyl paraben in 24%, 4% and 1.4% of samples, respectively. Urinary concentrations were highest for methyl paraben (median 39.8 μg/L; 95th percentile 319 μg/L) followed by n-propyl paraben (4.8 μg/L; 95th percentile 74.0 μg/L) and ethyl paraben (2.1 μg/L; 95th percentile 39.1 μg/L). Women had significantly higher urinary levels for all parabens than men, except for benzyl paraben. Samples from the ESB revealed that over the investigation period of nearly 20 years urinary paraben levels remained surprisingly constant; only methyl paraben had a significant increase, for both men and women. We found strong correlations between methyl- and n-propyl paraben and between n- and iso-butyl paraben. These results indicate that parabens are used in combination and arise from common sources of exposure. Urinary excretion factors are needed to extrapolate from individual urinary concentrations to actual doses. Copyright © 2015 Elsevier GmbH. All rights reserved.

  7. Comparison of ten different DNA extraction procedures with respect to their suitability for environmental samples.

    Science.gov (United States)

    Kuhn, Ramona; Böllmann, Jörg; Krahl, Kathrin; Bryant, Isaac Mbir; Martienssen, Marion

    2017-12-01

    DNA extraction for molecular biological applications usually requires target optimized extraction procedures depending on the origin of the samples. For environmental samples, a range of different procedures has been developed. We compared the applicability and efficiency of ten selected DNA extraction methods published in recent literature using four different environmental samples namely: activated sludge from a domestic wastewater treatment plant, river sediment, anaerobic digestion sludge and nitrifying enrichment culture. We assessed the suitability of the extraction procedures based on both DNA yield and quality. DNA quantification was performed by both ultra violet (UV) spectrophotometry and fluorescence spectrophotometry after staining with PicoGreen. In our study, DNA yields based on UV measurement were overestimated in most cases while DNA yields from fluorescence measurements correlated well with the sample load on agarose gels of crude DNA. The quality of the DNA extracts was determined by gel electrophoresis of crude DNA and PCR products from 16S rDNA with the universal primer set 27f/1525r. It was observed that gel electrophoresis of crude DNA was not always suitable to evaluate DNA integrity and purity since interfering background substances (e.g. humic substances) were not visible. Therefore, we strongly recommend examining the DNA quality of both crude DNA and 16S rDNA PCR products by gel electrophoresis when a new extraction method is established. Summarizing, we found four out of ten extraction procedures being applicable to all tested samples without noticeable restrictions. The procedure G (according to the standard method 432_10401 of the Lower Saxony State Office for Consumer Protection and Food Safety) had the broadest application range over procedure J (published by Wilson, 2001). These were followed by procedures F (Singka et al., 2012) and A (Bourrain et al., 1999). All four extraction procedures delivered reliable and reproducible crude

  8. Accurate and precise Pb isotope ratio measurements in environmental samples by MC-ICP-MS

    Science.gov (United States)

    Weiss, Dominik J.; Kober, Bernd; Dolgopolova, Alla; Gallagher, Kerry; Spiro, Baruch; Le Roux, Gaël; Mason, Thomas F. D.; Kylander, Malin; Coles, Barry J.

    2004-04-01

    Analytical protocols for accurate and precise Pb isotope ratio determinations in peat, lichen, vegetable, chimney dust, and ore-bearing granites using MC-ICP-MS and their application to environmental studies are presented. Acid dissolution of various matrix types was achieved using high temperature/high pressure microwave and hot plate digestion procedures. The digests were passed through a column packed with EiChrom Sr-resin employing only hydrochloric acid and one column passage. This simplified column chemistry allowed high sample throughput. Typically, internal precisions for approximately 30 ng Pb were below 100 ppm (+/-2[sigma]) on all Pb ratios in all matrices. Thallium was employed to correct for mass discrimination effects and the achieved accuracy was below 80 ppm for all ratios. This involved an optimization procedure for the 205Tl/203Tl ratio using least square fits relative to certified NIST-SRM 981 Pb values. The long-term reproducibility (+/-2[sigma]) for the NIST-SRM 981 Pb standard over a 5-month period (35 measurements) was better than 350 ppm for all ratios. Selected ore-bearing granites were measured with TIMS and MC-ICP-MS and showed good correlation (e.g., r=0.999 for 206Pb/207Pb ratios, slope=0.996, n=13). Mass bias and signal intensities of Tl spiked into natural (after matrix separation) and in synthetic samples did not differ significantly, indicating that any residual components of the complex peat and lichen matrix did not influence mass bias correction. Environmental samples with very different matrices were analyzed during two different studies: (i) lichens, vegetables, and chimney dust around a Cu smelter in the Urals, and (ii) peat samples from an ombrotrophic bog in the Faroe Islands. The presented procedure for sample preparation, mass spectrometry, and data processing tools resulted in accurate and precise Pb isotope data that allowed the reliable differentiation and identification of Pb sources with variations as small as 0

  9. Sampling

    CERN Document Server

    Thompson, Steven K

    2012-01-01

    Praise for the Second Edition "This book has never had a competitor. It is the only book that takes a broad approach to sampling . . . any good personal statistics library should include a copy of this book." —Technometrics "Well-written . . . an excellent book on an important subject. Highly recommended." —Choice "An ideal reference for scientific researchers and other professionals who use sampling." —Zentralblatt Math Features new developments in the field combined with all aspects of obtaining, interpreting, and using sample data Sampling provides an up-to-date treat

  10. Characterisation and optimisation of a sample preparation method for the detection and quantification of atmospherically relevant carbonyl compounds in aqueous medium

    Science.gov (United States)

    Rodigast, M.; Mutzel, A.; Iinuma, Y.; Haferkorn, S.; Herrmann, H.

    2015-06-01

    Carbonyl compounds are ubiquitous in the atmosphere and either emitted primarily from anthropogenic and biogenic sources or they are produced secondarily from the oxidation of volatile organic compounds. Despite a number of studies about the quantification of carbonyl compounds a comprehensive description of optimised methods is scarce for the quantification of atmospherically relevant carbonyl compounds. The method optimisation was conducted for seven atmospherically relevant carbonyl compounds including acrolein, benzaldehyde, glyoxal, methyl glyoxal, methacrolein, methyl vinyl ketone and 2,3-butanedione. O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine hydrochloride (PFBHA) was used as derivatisation reagent and the formed oximes were detected by gas chromatography/mass spectrometry (GC/MS). With the present method quantification can be carried out for each carbonyl compound originating from fog, cloud and rain or sampled from the gas- and particle phase in water. Detection limits between 0.01 and 0.17 μmol L-1 were found, depending on carbonyl compounds. Furthermore, best results were found for the derivatisation with a PFBHA concentration of 0.43 mg mL-1 for 24 h followed by a subsequent extraction with dichloromethane for 30 min at pH = 1. The optimised method was evaluated in the present study by the OH radical initiated oxidation of 3-methylbutanone in the aqueous phase. Methyl glyoxal and 2,3-butanedione were found to be oxidation products in the samples with a yield of 2% for methyl glyoxal and 14% for 2,3-butanedione after a reaction time of 5 h.

  11. Simultaneous determination of morphine, codeine and 6-acetyl morphine in human urine and blood samples using direct aqueous derivatisation: validation and application to real cases.

    Science.gov (United States)

    Chericoni, S; Stefanelli, F; Iannella, V; Giusiani, M

    2014-02-15

    Opiates play a relevant role in forensic toxicology and their assay in urine or blood is usually performed for example in workplace drug-testing or toxicological investigation of drug impaired driving. The present work describes two new methods for detecting morphine, codeine and 6-monoacethyl morphine in human urine or blood using a single step derivatisation in aqueous phase. Propyl chloroformate is used as the dramatizing agent followed by liquid-liquid extraction and gas-chromatography-mass spectroscopy to detect the derivatives. The methods have been validated both for hydrolysed and unhydrolysed urine. For hydrolysed urine, the LOD and LOQ were 2.5ng/ml and 8.5ng/ml for codeine, and 5.2ng/ml and 15.1ng/ml for morphine, respectively. For unhydrolysed urine, the LOD and LOQ were 3.0ng/ml and 10.1ng/ml for codeine, 2.7ng/ml and 8.1ng/ml for morphine, 0.8ng/ml and 1.5ng/ml for 6-monoacetyl morphine, respectively. In blood, the LOD and LOQ were 0.44ng/ml and 1.46ng/ml for codeine, 0.29ng/ml and 0.98ng/ml for morphine, 0.15ng/ml and 0.51ng/ml for 6-monoacetyl morphine, respectively. The validated methods have been applied to 50 urine samples and 40 blood samples (both positive and negative) and they can be used in routine analyses. Copyright © 2013 Elsevier B.V. All rights reserved.

  12. The SAMPL5 challenge for embedded-cluster integral equation theory: solvation free energies, aqueous p K a, and cyclohexane-water log D

    Science.gov (United States)

    Tielker, Nicolas; Tomazic, Daniel; Heil, Jochen; Kloss, Thomas; Ehrhart, Sebastian; Güssregen, Stefan; Schmidt, K. Friedemann; Kast, Stefan M.

    2016-11-01

    We predict cyclohexane-water distribution coefficients (log D 7.4) for drug-like molecules taken from the SAMPL5 blind prediction challenge by the "embedded cluster reference interaction site model" (EC-RISM) integral equation theory. This task involves the coupled problem of predicting both partition coefficients (log P) of neutral species between the solvents and aqueous acidity constants (p K a) in order to account for a change of protonation states. The first issue is addressed by calibrating an EC-RISM-based model for solvation free energies derived from the "Minnesota Solvation Database" (MNSOL) for both water and cyclohexane utilizing a correction based on the partial molar volume, yielding a root mean square error (RMSE) of 2.4 kcal mol-1 for water and 0.8-0.9 kcal mol-1 for cyclohexane depending on the parametrization. The second one is treated by employing on one hand an empirical p K a model (MoKa) and, on the other hand, an EC-RISM-derived regression of published acidity constants (RMSE of 1.5 for a single model covering acids and bases). In total, at most 8 adjustable parameters are necessary (2-3 for each solvent and two for the p K a) for training solvation and acidity models. Applying the final models to the log D 7.4 dataset corresponds to evaluating an independent test set comprising other, composite observables, yielding, for different cyclohexane parametrizations, 2.0-2.1 for the RMSE with the first and 2.2-2.8 with the combined first and second SAMPL5 data set batches. Notably, a pure log P model (assuming neutral species only) performs statistically similarly for these particular compounds. The nature of the approximations and possible perspectives for future developments are discussed.

  13. Comparison of air-agitated liquid-liquid microextraction technique and conventional dispersive liquid-liquid micro-extraction for determination of triazole pesticides in aqueous samples by gas chromatography with flame ionization detection.

    Science.gov (United States)

    Farajzadeh, Mir Ali; Mogaddam, Mohammad Reza Afshar; Aghdam, Abdollah Abdollahi

    2013-07-26

    Two micro-extraction methods, air-agitated liquid-liquid microextraction (AALLME) and dispersive liquid-liquid microextraction (DLLME), have been compared with each other by applying them for the analysis of five triazole pesticides (penconazole, hexaconazole, diniconazole, tebuconazole and triticonazole) in aqueous samples by gas chromatography with flame ionization detection (GC-FID). In the AALLME method, which excludes any disperser solvent, much less volume of organic solvent is used. In order to form fine and dispersed organic droplets in the aqueous phase, the mixture of aqueous sample solution and extraction solvent is repeatedly aspirated and dispensed with a syringe. In the DLLME method, an appropriate mixture of extraction solvent and disperser solvent is rapidly injected by a syringe into the aqueous sample. Effect of the pertinent experimental factors on DLLME (i.e. identity and volume of the extraction and disperser solvents and ionic strength) and on AALLME (identity and volume of the extraction solvent, number of agitations, and ionic strength) were investigated. Under optimal conditions, limits of detection for the five target pesticides obtained by AALLME-GC-FID and DLLME-GC-FID ranged from 0.20 to 1.1ngmL(-1) and 1.9 to 5.9ngmL(-1), respectively. The relative standard deviations (RSDs, n=5) were in the range of 1-4% and 3-5% with the enrichment factors of 449-504 and 79-143 for AALLME-GC-FID and DLLME-GC-FID, respectively. Both of the compared methods are simple, fast, efficient, inexpensive and can be applied to the analysis of the five pesticides in different aqueous samples in which penconazole and hexaconazole were found. For spiked samples, the recoveries were in the ranges of 92-105%, and 92-104% for AALLME and DLLME, respectively. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Magnetic Study on Environmental Samples from Guadalajara Mexico for Monitoring of Atmospheric Pollution

    Science.gov (United States)

    Aguilar, B.; Cejudo, R.; Bogalo, M. F.; Rosas-Elguera, J.; Quintana, P.; Bautista, F.; Gogichaishvili, A.; Morales, J.

    2013-05-01

    Guadalajara is the second bigger city in Mexico, catalogued as critical zone because of atmospheric pollution levels. The magnetic methodology has been largely used as an alternative way to evaluate the pollution levels as well as identify the critical points in a given area. In this work, results from chemical analyses and magnetic measurements are presented in order to show the correlation between magnetic signal and the pollution level. We analyzed three kinds of environmental samples: urban soils, urban dust and leaves from ficus benjamina. Samples were taken in 30 sites distributed along a main avenue and two secondary avenues, including three points with very poor traffic influence. We determined a ferromagnetic carrier in most of samples, magnetite probably, since the Tc calculated from the thermomagnetic curves is around 580 °C. The magnetic susceptibility (Xlf) as well as the Saturation Isothermal Remanent Magnetization (SIRM) correlate well with the heavy metals content, specially Pb in urban dusts. These results allowed us to identify the most affected points, by vehicular traffic and industrial emissions. Furthermore, the values obtained for these magnetic parameters are above of those found in other studies for polluted cities in Europe and Asia.

  15. [Spina bifida occulta associated with environmental arsenic exposure in a prehispanic sample from northern Chile].

    Science.gov (United States)

    Silva-Pinto, Verónica; Arriaza, Bernardo; Standen, Vivien

    2010-04-01

    The Camarones River Valley, located in the extreme north of Chile, is characterized by high environmental arsenic levels and an arid desert. It has been inhabited by humans for the past 7,000 years. Evidence exists for chronic arsenic poisoning in both prehispanic and present populations residing in the area. Chronic arsenic exposure causes multi-systemic problems and can induce congenital malformations, in particular neural tube development defects such as spina bifida. To study the prevalence of spina bifida among prehispanic mummies of the area. One hundred and twenty prehistoric adult individuals were analyzed for evidence of spina bifda occulta of the sacrum in skeletal samples from the sites of Camarones 8, Camarones 9, Azapa 140 and Lluta 54, held in repository at the Museo Universidad de Tarapacá de Arica- San Miguel de Azapa. A diagnosis was considered positive when at least S1, S2 or S3 were affected. As controls, mummies of individuals that resided in Lluta and Azapa valley, with a low arsenic exposure, were analyzed. The frequency of spina bifida occulta among samples from the Camarones coast and Lluta and Azapa Valley were 13.5 and 2.4% respectively. Considering these were contemporaneous samples, and are believed to have had no other differences in diet or other factors, the differential exposures to arsenic could have produced the observed differences in spina bifida frequencies.

  16. A bioassay for the detection of benzimidazoles reveals their presence in a range of environmental samples

    Directory of Open Access Journals (Sweden)

    Terence S Crofts

    2014-11-01

    Full Text Available Cobamides are a family of enzyme cofactors that include vitamin B12 (cobalamin and are produced solely by prokaryotes. Structural variability in the lower axial ligand has been observed in cobamides produced by diverse organisms. Of the three classes of lower ligands, the benzimidazoles are uniquely found in cobamides, whereas the purine and phenolic bases have additional biological functions. Many organisms acquire cobamides by salvaging and remodeling cobamides or their precursors from the environment. These processes require free benzimidazoles for incorporation as lower ligands, though the presence of benzimidazoles in the environment has not been previously investigated. Here, we report a new purification method and bioassay to measure the total free benzimidazole content of samples from microbial communities and laboratory media components. The bioassay relies on the calcofluor-bright phenotype of a bluB mutant of the model cobalamin-producing bacterium Sinorhizobium meliloti. The concentrations of individual benzimidazoles in these samples were measured by liquid chromatography-tandem mass spectrometry. Several benzimidazoles were detected in subpicomolar to subnanomolar concentrations in host-associated and environmental samples. In addition, benzimidazoles were found to be common contaminants of laboratory media components. These results suggest that benzimidazoles present in the environment and in laboratory media have the potential to influence microbial metabolic activities.

  17. ENVIRONMENTAL TECHNOLOGY VERIFICATION REPORT, GROUNDWATER SAMPLING TECHNOLOGIES, GEOPROBE INC., PNEUMATIC BLADDER PUMP GW 1400 SERIES

    Science.gov (United States)

    The U.S. Environmental Protection Agency (EPA) design efficient processes for conducting has created the Environmental Technology perfofl1lance tests of innovative technologies. Verification Program (E TV) to facilitate the deployment of innovative or improved environmental techn...

  18. Atmospheric pressure gas chromatography-time-of-flight-mass spectrometry (APGC-ToF-MS) for the determination of regulated and emerging contaminants in aqueous samples after stir bar sorptive extraction (SBSE).

    Science.gov (United States)

    Pintado-Herrera, Marina G; González-Mazo, Eduardo; Lara-Martín, Pablo A

    2014-12-03

    This work presents the development, optimization and validation of a multi-residue method for the simultaneous determination of 102 contaminants, including fragrances, UV filters, repellents, endocrine disruptors, biocides, polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs), and several types of pesticides in aqueous matrices. Water samples were processed using stir bar sorptive extraction (SBSE) after the optimization of several parameters: agitation time, ionic strength, presence of organic modifiers, pH, and volume of the derivatizing agent. Target compounds were extracted from the bars by liquid desorption (LD). Separation, identification and quantification of analytes were carried out by gas chromatography (GC) coupled to time-of-flight (ToF-MS) mass spectrometry. A new ionization source, atmospheric pressure gas chromatography (APGC), was tested. The optimized protocol showed acceptable recovery percentages (50-100%) and limits of detection below 1ngL(-1) for most of the compounds. Occurrence of 21 out of 102 analytes was confirmed in several environmental aquatic matrices, including seawater, sewage effluent, river water and groundwater. Non-target compounds such as organophosphorus flame retardants were also identified in real samples by accurate mass measurement of their molecular ions using GC-APGC-ToF-MS. To the best of our knowledge, this is the first time that this technique has been applied for the analysis of contaminants in aquatic systems. By employing lower energy than the more widely used electron impact ionization (EI), AGPC provides significant advantages over EI for those substances very susceptible to high fragmentation (e.g., fragrances, pyrethroids). Copyright © 2014 Elsevier B.V. All rights reserved.

  19. Electrochemical Exfoliation of Graphite in Aqueous Sodium Halide Electrolytes toward Low Oxygen Content Graphene for Energy and Environmental Applications.

    Science.gov (United States)

    Munuera, J M; Paredes, J I; Enterría, M; Pagán, A; Villar-Rodil, S; Pereira, M F R; Martins, J I; Figueiredo, J L; Cenis, J L; Martínez-Alonso, A; Tascón, J M D

    2017-07-19

    Graphene and graphene-based materials have shown great promise in many technological applications, but their large-scale production and processing by simple and cost-effective means still constitute significant issues in the path of their widespread implementation. Here, we investigate a straightforward method for the preparation of a ready-to-use and low oxygen content graphene material that is based on electrochemical (anodic) delamination of graphite in aqueous medium with sodium halides as the electrolyte. Contrary to previous conflicting reports on the ability of halide anions to act as efficient exfoliating electrolytes in electrochemical graphene exfoliation, we show that proper choice of both graphite electrode (e.g., graphite foil) and sodium halide concentration readily leads to the generation of large quantities of single-/few-layer graphene nanosheets possessing a degree of oxidation (O/C ratio down to ∼0.06) lower than that typical of anodically exfoliated graphenes obtained with commonly used electrolytes. The halide anions are thought to play a role in mitigating the oxidation of the graphene lattice during exfoliation, which is also discussed and rationalized. The as-exfoliated graphene materials exhibited a three-dimensional morphology that was suitable for their practical use without the need to resort to any kind of postproduction processing. When tested as dye adsorbents, they outperformed many previously reported graphene-based materials (e.g., they adsorbed ∼920 mg g -1 for methyl orange) and were useful sorbents for oils and nonpolar organic solvents. Supercapacitor cells assembled directly from the as-exfoliated products delivered energy and power density values (up to 15.3 Wh kg -1 and 3220 W kg -1 , respectively) competitive with those of many other graphene-based devices but with the additional advantage of extreme simplicity of preparation.

  20. Environmental methodology. Sampling and preparing fresh water organisms. Measuring of emitting radionuclides

    International Nuclear Information System (INIS)

    Foulquier, Luc; Philippot, J.C.; Baudin-Jaulent, Yvette.

    1982-05-01

    This paper provides some initial responses to questions asked by users of radioecological documents. By using aquatic plants and fish drawn ''in situ'' the authors' results often reveal very low activity levels; they make a point of knowing how to deal with such levels, since the fundamental objective is to interpret transfer mechanisms. The establishment of the environmental level of radioactivity requires that the write-ups produced demonstrate the use of reproducible methods, and contain results for which the extent of reliability is clearly specified. Aquatic plants and fish are, among all fresh water organisms, the most interesting links in the study of artificial and natural radioactivity. By systematically using concrete examples, this work reaffirms the precautions that should be taken in a site study. Once the objective is clearly defined, the properties to give to the sampling can be specified [fr

  1. Determination of uranium isotopes in environmental samples by anion exchange in sulfuric and hydrochloric acid media.

    Science.gov (United States)

    Popov, L

    2016-09-01

    Method for determination of uranium isotopes in various environmental samples is presented. The major advantages of the method are the low cost of the analysis, high radiochemical yields and good decontamination factors from the matrix elements, natural and man-made radionuclides. The separation and purification of uranium is attained by adsorption with strong base anion exchange resin in sulfuric and hydrochloric acid media. Uranium is electrodeposited on a stainless steel disk and measured by alpha spectrometry. The analytical method has been applied for the determination of concentrations of uranium isotopes in mineral, spring and tap waters from Bulgaria. The analytical quality was checked by analyzing reference materials. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Dynamic Flow-through Methods for Metal Fractionation in Environmental Solid Samples

    DEFF Research Database (Denmark)

    Miró, Manuel; Hansen, Elo Harald; Petersen, Roongrat

    Accummulation of metal ions in different compartments of the biosphere and their possible mobilization under changing environmental conditions induce a pertubation of the ecosystem and may cause adverse health effects. Nowadays, it is widely recognized that the information on total content...... to the state-of-the-art and fundamental principles of automated, miniaturized strategies for on-line fractionation studies based on the concepts of stirring chambers, rotating coiled columns and packed microcartridges, mostly exploiting the attractive features of the first and second generations of flow...... availability; (2) Simplification of the overall procedure (from days to hours); (3) Automation of the extraction procedure and detection; (4) Minimization of risks of sample contamination; (5) Easy manipulation of reagents via Sequential Injection schemes; (6) Ability to implement a multitude of operational...

  3. Determination of rhenium in biological and environmental samples by radiochemical neutron activation analysis

    International Nuclear Information System (INIS)

    Kucera, J.; Mizera, J.; Randa, Z.; Byrne, A.R.; Lucanikova, M.

    2006-01-01

    Radiochemical neutron activation procedures using liquid-liquid extraction with tetraphenylarsonium chloride in chloroform from 1 M HCl and solid extraction with ALIQUAT 336 incorporated in a polyacrylonitrile binding matrix from 0.1 M HCl were developed for accurate determination of rhenium in biological and environmental samples at the sub-ng.g -1 level. Concentrations of Re in the range of 0.1 to 2.4 ng.g -1 were determined in several botanical reference materials (RM), while in a RM of road dust a value of approx. 10 ng.g -1 was found. Significantly elevated values of Re, up to 90 ng.g -1 , were found in seaweed (brown algae). Results for Re in the brown algae Fucus vesiculosus in which elevated 99 Tc values had previously been determined suggest possible competition between Re and Tc in the accumulation process. (author)

  4. Code Betal to calculation Alpha/Beta activities in environmental samples

    International Nuclear Information System (INIS)

    Romero, L.; Travesi, A.

    1983-01-01

    A codes, BETAL, was developed, written in FORTRAN IV, to automatize calculations and presentations of the result of the total alpha-beta activities measurements in environmental samples. This code performs the necessary calculations for transformation the activities measured in total counts, to pCi/1., bearing in mind the efficiency of the detector used and the other necessary parameters. Further more, it appraise the standard deviation of the result, and calculus the Lower limit of detection for each measurement. This code is written in iterative way by screen-operator dialogue, and asking the necessary data to perform the calculation of the activity in each case by a screen label. The code could be executed through any screen and keyboard terminal, (whose computer accepts Fortran IV) with a printer connected to the said computer. (Author) 5 refs

  5. Treatment of the recovery bias in the determination of Sr-90 in environmental samples

    International Nuclear Information System (INIS)

    AbdelFattah, A.T.

    1991-01-01

    The yttrium yields, in the determination of Sr-90 in environmental samples as obtained by several laboratories were found to be greater than 100%. To decrease this gravimetric error, a barium sulphate precipitation step followed the strontium yttrium separation, to scavenge any traces of strontium or calcium. The yttrium recovery was decreased to values lower than 100% as expected. Consequently, an increase of 5-8% in the counting efficiency of Y-90 was obtained while that of Sr-90 remained unchanged. Another bias has been met in comparing the gravimetric to the radiometric recoveries, called the recovery bias and is equal to Grav. Rec.-Rad.Rec. x 100/ Rad. Rec. For treating this recovery bias, two different procedures were used including the use of different chemical separation steps and different strontium carrier concentrations. These are the American Society for Testing and Materials (ASTM) and the Yankee Atomic Environmental Lab.(YAEL) procedures. It was found that the use of YAEL procedure with the higher strontium carrier concentration (50 mg/ml) of the ASTM leads to an acceptable recovery bias.2 fig.,1 tab

  6. Graphene-functionalized melamine sponges for microextraction of sulfonamides from food and environmental samples.

    Science.gov (United States)

    Chatzimitakos, Theodoros; Samanidou, Victoria; Stalikas, Constantine D

    2017-11-03

    The study describes the functionalization of melamine sponges with graphene and its use as an adsorbent for the microextraction of sulfonamides from food and environmental samples. The graphene-functionalized melamine sponge (GMeS) was prepared by an easy, one-step procedure, which complies with the principles of green chemistry and is proved advantageous over previously described methods. The applicability of the GMeS in extraction procedures was studied and an analytical method for the determination of sulfonamides in milk, eggs and lake water was developed and validated according to SANCO/12571/2013 guideline. The developed method was highly accurate and reproducible, while the limits of quantification were found to be relatively low (0.31-0.91μgkg -1 , 0.96-1.32μgkg -1 and 0.10-0.29μgL -1 in the case of milk, eggs and lake water respectively). Furthermore, matrix effects were absent in all cases, since the microextraction procedure serves also as a clean-up step. The low cost of synthesis, the environmentally friendly conditions, the efficiency and high extraction recoveries are some additional advantages of the proposed procedure. To the best of our knowledge, this is the first time that a GMeS is prepared in a straightforward way and used for analytical purposes. Copyright © 2017 Elsevier B.V. All rights reserved.

  7. Species and Strain-specific Typing of Cryptosporidium Parasites in Clinical and Environmental Samples

    Directory of Open Access Journals (Sweden)

    Xiao Lihua

    1998-01-01

    Full Text Available Cryptosporidiosis has recently attracted attention as an emerging waterborne and foodborne disease as well as an opportunistic infection in HIV infected individuals. The lack of genetic information, however, has resulted in confusion in the taxonomy of Cryptosporidium parasites and in the development of molecular tools for the identification and typing of oocysts in environmental samples. Phylogenetic analysis of the small subunit ribosomal RNA (SSU rRNA gene has shown that the genus Cryptosporidium is comprised of several distinct species. Our data show the presence of at least four species: C. parvum, C. muris, C. baileyi and C. serpentis (C. meleagridis, C. nasorum and C. felis were not studied. Within each species, there is some sequence variation. Thus, various genotypes (genotype 1, genotype 2, guinea pig genotype, monkey genotype and koala genotype, etc. of C. parvum differ from each other in six regions of the SSU rRNA gene. Information on polymorphism in Cryptosporidium parasites has been used in the development of species and strain-specific diagnostic tools. Use of these tools in the characterization of oocysts various samples indicates that C. parvum genotype 1 is the strain responsible for most human Cryptosporidium infections. In contrast, genotype 2 is probably the major source for environmental contamination of environment, and has been found in most oysters examined from Chesapeake Bay that serve as biologic monitors of surface water. Parasites of Cryptosporidium species other than C. parvum have not been detected in HIV+ individuals, indicating that the disease in humans is caused only by C. parvum.

  8. Evaluation of precision and accuracy of neutron activation analysis method of environmental samples analysis

    International Nuclear Information System (INIS)

    Wardani, Sri; Rina M, Th.; L, Dyah

    2000-01-01

    Evaluation of precision and accuracy of Neutron Activation Analysis (NAA) method used by P2TRR performed by analyzed the standard reference samples from the National Institute of Environmental Study of Japan (NIES-CRM No.10 (rice flour) and the National Bureau of USA (NBS-SRM 1573a (tomato leave) by NAA method. In analyze the environmental SRM No.10 by NAA method in qualitatively could identified multi elements of contents, namely: Br, Ca, Co, CI, Cs, Gd, I, K< La, Mg, Mn, Na, Pa, Sb, Sm, Sr, Ta, Th, and Zn (19 elements) for SRM 1573a; As, Br, Cr, CI, Ce, Co, Cs, Fe, Ga, Hg, K, Mn, Mg, Mo, Na, Ni, Pb, Rb, Sr, Se, Sc, Sb, Ti, and Zn, (25 elements) for CRM No.10a; Ag, As, Br, Cr, CI, Ce, Cd, Co, Cs, Eu, Fe, Ga, Hg, K, Mg, Mn, Mo, Na, Nb, Pb, Rb, Sb, Sc, Th, TI, and Zn, (26 elements) for CRM No. 10b; As, Br, Co, CI, Ce, Cd, Ga, Hg, K, Mn, Mg, Mo, Na, Nb, Pb, Rb, Sb, Se, TI, and Zn (20 elementary) for CRM No.10c. In the quantitatively analysis could determined only some element of sample contents, namely: As, Co, Cd, Mo, Mn, and Zn. From the result compared with NIES or NBS values attained with deviation of 3% ∼ 15%. Overall, the result shown that the method and facilities have a good capability, but the irradiation facility and the software of spectrometry gamma ray necessary to developing or seriously research perform

  9. Environmental Sampling FY03 Annual Report - Understanding the Movement of Mercury on the INEEL

    International Nuclear Information System (INIS)

    Michael L. Abbott

    2003-01-01

    Environmental mercury measurements were started in Fy-01 at the Idaho National Engineering Laboratory (INEEL) to monitor downwind impacts from on-going waste treatment operations at the Idaho Nuclear Technology and Engineering Center (INTEC) and to improve our scientific understanding of mercury fate and transport in this region. This document provides a summary of the sampling done in FY04. Continuous total gaseous mercury (TGM) measurements were made using a Tekran Model 2537A mercury vapor analyzer during October 2002 and from February through July 2003. The equipment was deployed in a self-contained field trailer at the Experimental Field Station (EFS) four kilometers downwind (northeast) of INTEC. Mercury surface-to-air flux measurements were made in October 2002 and from February through May 2003 to better understand the fate of the estimated 1500 kg of mercury emitted from 36 years of calciner operations at INTEC and to improve our scientific understanding of mercury environmental cycling in this region. Flux was measured using an INEEL-designed dynamic flux chamber system with a Tekran automated dual sampling (TADS) unit. Diel flux was positively correlated with solar radiation (r = 0.65), air temperature (r = 0.64), and wind speed (r = 0.38), and a general linear model for flux prediction at the INEEL was developed. Reactive gaseous mercury (RGM) was measured at EFS in July using a Tekran Model 1130 mercury speciation unit. Based on comparisons with other published data around the U.S., mercury air concentrations and surface flux rates directly downwind from INTEC were not distinguishable from remote area (non-industrial) background levels during the monitoring period

  10. Bright environmental light ameliorates deficient subjective liking in insomnia: an experience sampling study.

    Science.gov (United States)

    Te Lindert, Bart H W; Itzhacki, Jacob; van der Meijden, Wisse P; Kringelbach, Morten L; Mendoza, Jorge; Van Someren, Eus J W

    2018-02-07

    Altered comfort sensing and reduced gray matter volume in the orbitofrontal cortex of the brain in people suffering from Insomnia Disorder (ID) suggest compromised processes of motivation and hedonia. The Experience Sampling (ES) method was used to evaluate whether, in naturalistic conditions, people with ID differ from those without sleep complaints with respect to subjective wanting and liking, two major dimensions of the reward system. Since light affects brain circuits involved in affect and reward, ES was combined with ambulatory monitoring of light intensity fluctuations to evaluate their effect on subjective wanting and liking. Participants with ID (n=17, 12 females, 56.8 ± 6.5 mean ± standard deviation years of age) and matched controls without sleep complaints (n=18, 12 females, 57.0 ± 8.6 years of age) were probed by a smartphone alarm to log their subjective wanting, liking and mood nine times a day for seven days. Using an ambulatory light recorder, light intensity exposure was sampled simultaneously and averaged over the intervals between subsequent ES alarms. Mixed effect models were used to evaluate how ID and varying light intensity affected subjective assessments. The results indicated significantly lower subjective Liking and Wanting in people suffering from ID, particularly at low environmental light intensity. Wanting and liking, rather than more commonly used mood adjectives, showed an increased sensitivity to detect deficient hedonic and reward processing in insomnia during everyday life. Deficient liking may in part be rescued by exposure to bright environmental light. © Sleep Research Society 2018. Published by Oxford University Press on behalf of the Sleep Research Society. All rights reserved. For permissions, please e-mail journals.permissions@oup.com.

  11. A novel method for the determination of /sup 99/Tc in the environmental samples using ICP-MS

    International Nuclear Information System (INIS)

    Ihsanullah.

    1991-08-01

    A radiochemical procedure for the determination of /sup 99/Tc to overcome the problems of presentation of the sample for ICP-MS and the low specific radioactivity found in environmental samples is optimised. The percentage chemical yield for water and soil samples was found to be around 65 and for biological samples about 70. The limit of detection of /sup 99/Tc by ICP-MS was 0.004 ppb. (author)

  12. Sample preparation method for ICP-MS measurement of 99Tc in a large amount of environmental samples

    International Nuclear Information System (INIS)

    Kondo, M.; Seki, R.

    2002-01-01

    Sample preparation for measurement of 99 Tc in a large amount of soil and water samples by ICP-MS has been developed using 95m Tc as a yield tracer. This method is based on the conventional method for a small amount of soil samples using incineration, acid digestion, extraction chromatography (TEVA resin) and ICP-MS measurement. Preliminary concentration of Tc has been introduced by co-precipitation with ferric oxide. The matrix materials in a large amount of samples were more sufficiently removed with keeping the high recovery of Tc than previous method. The recovery of Tc was 70-80% for 100 g soil samples and 60-70% for 500 g of soil and 500 L of water samples. The detection limit of this method was evaluated as 0.054 mBq/kg in 500 g soil and 0.032 μBq/L in 500 L water. The determined value of 99 Tc in the IAEA-375 (soil sample collected near the Chernobyl Nuclear Reactor) was 0.25 ± 0.02 Bq/kg. (author)

  13. Determination of Kr-85 in environmental samples and gaseous effluents from nuclear industries using the standard method

    International Nuclear Information System (INIS)

    Heras Iniquez, M.C.; Perez Garcia, M.M.

    1983-01-01

    The determination of the Kr-85 activity in environmental samples and gaseous effluents from Spanish Nuclear Power Stations is described. The method employed has been published elsewhere. The determinations has been carried out in environmental samples token at JEN Laboratories (Madrid) and the Nuclear Power Stations, Jose Cabrera (Zorita), Garona and Vandellos. Also samples of gaseous effluents of the three plants has been analyzed. Values of the Kr-85 environmental background activity in the Almaraz Nuclear Power Stations, has been determined, before the beginning of its nuclear activity. In this paper the sampling equipment used is described and the values found of Kr-85 activity in all the samples in given. (Author) 29 refs

  14. Oak ridge national laboratory automated clean chemistry for bulk analysis of environmental swipe samples

    Energy Technology Data Exchange (ETDEWEB)

    Bostick, Debra A. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hexel, Cole R. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Ticknor, Brian W. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Tevepaugh, Kayron N. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Metzger, Shalina C. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2016-11-01

    To shorten the lengthy and costly manual chemical purification procedures, sample preparation methods for mass spectrometry are being automated using commercial-off-the-shelf (COTS) equipment. This addresses a serious need in the nuclear safeguards community to debottleneck the separation of U and Pu in environmental samples—currently performed by overburdened chemists—with a method that allows unattended, overnight operation. In collaboration with Elemental Scientific Inc., the prepFAST-MC2 was designed based on current COTS equipment that was modified for U/Pu separations utilizing Eichrom™ TEVA and UTEVA resins. Initial verification of individual columns yielded small elution volumes with consistent elution profiles and good recovery. Combined column calibration demonstrated ample separation without crosscontamination of the eluent. Automated packing and unpacking of the built-in columns initially showed >15% deviation in resin loading by weight, which can lead to inconsistent separations. Optimization of the packing and unpacking methods led to a reduction in the variability of the packed resin to less than 5% daily. The reproducibility of the automated system was tested with samples containing 30 ng U and 15 pg Pu, which were separated in a series with alternating reagent blanks. These experiments showed very good washout of both the resin and the sample from the columns as evidenced by low blank values. Analysis of the major and minor isotope ratios for U and Pu provided values well within data quality limits for the International Atomic Energy Agency. Additionally, system process blanks spiked with 233U and 244Pu tracers were separated using the automated system after it was moved outside of a clean room and yielded levels equivalent to clean room blanks, confirming that the system can produce high quality results without the need for expensive clean room infrastructure. Comparison of the amount of personnel time necessary for successful manual vs

  15. An Environmentally Benign Protocol for Aqueous Synthesis of Tetrahydrobenzo[b]Pyrans Catalyzed by Cost-Effective Ionic Liquid

    Directory of Open Access Journals (Sweden)

    Huanan Hu

    2014-04-01

    Full Text Available A mild, efficient, and environmentally benign protocol for the synthesis of tetrahydrobenzo[b]pyran derivatives in the presence of readily accessible, biodegradable, and choline hydroxide based ionic liquid as catalyst has been established. The key features of the reported methodology include good to excellent yields of desired products, simple work-up procedure and good recyclability of catalysts, which may be a practical alternative to the existing conventional processes for the preparation of 4-H pyrans to cater to the requirements of academia as well as industry.

  16. Open focused microwave-assisted sample preparation for rapid total and mercury species determination in environmental solid samples

    OpenAIRE

    Tseng, C. M.; Garraud, H.; Amouroux, D.; Donard, O. F. X.; de Diego, A.

    1998-01-01

    This paper describes rapid, simple microwave-assisted leaching/ digestion procedures for total and mercury species determination in sediment samples and biomaterials. An open focused microwave system allowed the sample preparation time to be dramatically reduced to only 24 min when a power of 40-80 W was applied. Quantitative leaching of methylmercury from sediments by HNO3 solution and complete dissolution of biomaterials by an alkaline solution, such as 25% TMAH solution, were obtained. Met...

  17. Ecological risk evaluation of sediment core samples, Lake Tortum (Erzurum, NE Turkey using environmental indices

    Directory of Open Access Journals (Sweden)

    Hakan Kaya

    2017-11-01

    Full Text Available This study aimed to determine the vertical distribution of heavy metals in a 72 cm-long core sample from Lake Tortum in order to shed light on the implications of potential ecological risks. Analysis was based on the use of environmental indices such as the Integrated Pollution Load Index (PLI and Potential Ecological Risk Index (PER. Results reveal that, except for Pb, Mn and Hg, the lowest concentrations of heavy metals occur at a core depth of between 2 cm and 20 cm for Cu, Zn, Ni, Fe, As, Cd, Cr and Al. The highest concentration was found at sampling intervals of 36 cm and 50 cm, with the exception of Pb, Mn, Hg and Ni. The PLI values from bottom to top are less than 1 while the level with the nearest value to the background value lies at a depth between 24 cm and 26 cm. The PER index results suggest a low ecological risk level for Cu, Pb, Zn, Ni, Mn, Fe, As, Cr, and Al; however, Cd and Hg constitute an ecological threat to the lake ecosystem.

  18. Colorimetric recognition of 6-benzylaminopurine in environmental samples by using thioglycolic acid functionalized silver nanoparticles

    Science.gov (United States)

    Zheng, Mingda; He, Jiang; Wang, Yingying; Wang, Chenge; Ma, Shuang; Sun, Xiaohan

    2018-03-01

    A simple and selective colorimetric sensor thioglycolic acid capped silver nanoparticles (TGA-AgNPs) was developed for the detection of 6-benzylaminopurine (6-BAP). The synthesized TGA-AgNPs were characterized by UV-vis spectroscopy, dynamic light scattering (DLS), and transmission electron microscopic (TEM) techniques. The TGA-AgNPs as a sensor for binding 6-BAP through hydrogen-bonding and π-π bonding that causes large conjugate clusters, resulting in a color change from yellow to reddish orange. The surface plasmon resonance (SPR) band of TGA-AgNPs at 397 nm is red-shifted to 510 nm, which confirms that 6-BAP induces the aggregation of TGA-AgNPs. Under the optimized conditions, a linear relationship between the absorption ratio (A510 nm/A397 nm) and 6-BAP concentration was found in the range of 4-26 μM. The detection limit of 6-BAP was 0.2 μM, which is lower than the other analytical techniques. Moreover, the proposed sensor was successfully applied for the detection of 6-BAP in environmental samples with good recoveries. The proposed assay provides a simple and cost-effective method for the analysis of 6-BAP in vegetable and water samples.

  19. Preconcentration system for cadmium and lead determination in environmental samples using polyurethane foam/Me-BTANC

    International Nuclear Information System (INIS)

    Moreira Gama, Ednilton; Silva Lima, Adriana da; Azevedo Lemos, Valfredo

    2006-01-01

    In this work, polyurethane foam (PUF) loaded with 2-(6'-methyl-2'-benzothiazolylazo)chromotropic acid (Me-BTANC) was packed in a minicolumn and it was used in an on-line preconcentration system for cadmium and lead determination. Optimum hydrodynamic and chemical conditions for metal sorption were investigated. The effects of several foreign substances on the adsorption of cadmium and lead were also reported. The enrichment factor obtained was 37 (Cd and Pb) for 180 s preconcentration time. The proposed procedures allowed the determination of metals with detection limits (3σ) of 0.80 and 3.75 μg L -1 (0.10 and 0.47 μg g -1 of solid sample) for cadmium and lead, respectively. The precision of the procedures was also calculated: 3.1 (Cd 10 μg L -1 ) and 4.4% (Pb 100 μg L -1 ). The accuracy of the procedure was checked by analysis of the certified reference materials Spinach Leaves and Fish Tissue. Cadmium and lead contents in environmental samples (black tea, spinach leaves, natural and tap water) were determined by applying the proposed procedure

  20. Impact of sample size on principal component analysis ordination of an environmental data set: effects on eigenstructure

    Directory of Open Access Journals (Sweden)

    Shaukat S. Shahid

    2016-06-01

    Full Text Available In this study, we used bootstrap simulation of a real data set to investigate the impact of sample size (N = 20, 30, 40 and 50 on the eigenvalues and eigenvectors resulting from principal component analysis (PCA. For each sample size, 100 bootstrap samples were drawn from environmental data matrix pertaining to water quality variables (p = 22 of a small data set comprising of 55 samples (stations from where water samples were collected. Because in ecology and environmental sciences the data sets are invariably small owing to high cost of collection and analysis of samples, we restricted our study to relatively small sample sizes. We focused attention on comparison of first 6 eigenvectors and first 10 eigenvalues. Data sets were compared using agglomerative cluster analysis using Ward’s method that does not require any stringent distributional assumptions.

  1. Comparison of air samples, nasal swabs, ear-skin swabs and environmental dust samples for detection of Methicillin Resistant Staphylococcus aureus (MRSA) in pig herds

    DEFF Research Database (Denmark)

    Agersø, Yvonne; Vigre, Håkan; Cavaco, Lina

    2014-01-01

    To identify a cost-effective and practical method for detection of methicillin-resistant Staphylococcus aureus (MRSA) in pig herds, the relative sensitivity of four sample types: nasal swabs, ear-skin (skin behind the ears) swabs, environmental dust swabs and air was compared. Moreover, dependency......-herd prevalence ⩾25%]. The results indicate that taking swabs of skin behind the ears (ten pools of five) was even more sensitive than taking nasal swabs (ten pools of five) at the herd level and detected significantly more positive samples. spa types t011, t034 and t4208 were observed. In conclusion, MRSA...... detection by air sampling is easy to perform, reduces costs and analytical time compared to existing methods, and is recommended for initial testing of herds. Ear-skin swab sampling may be more sensitive for MRSA detection than air sampling or nasal swab sampling....

  2. Environmental DNA from Seawater Samples Correlate with Trawl Catches of Subarctic, Deepwater Fishes.

    Directory of Open Access Journals (Sweden)

    Philip Francis Thomsen

    Full Text Available Remote polar and deepwater fish faunas are under pressure from ongoing climate change and increasing fishing effort. However, these fish communities are difficult to monitor for logistic and financial reasons. Currently, monitoring of marine fishes largely relies on invasive techniques such as bottom trawling, and on official reporting of global catches, which can be unreliable. Thus, there is need for alternative and non-invasive techniques for qualitative and quantitative oceanic fish surveys. Here we report environmental DNA (eDNA metabarcoding of seawater samples from continental slope depths in Southwest Greenland. We collected seawater samples at depths of 188-918 m and compared seawater eDNA to catch data from trawling. We used Illumina sequencing of PCR products to demonstrate that eDNA reads show equivalence to fishing catch data obtained from trawling. Twenty-six families were found with both trawling and eDNA, while three families were found only with eDNA and two families were found only with trawling. Key commercial fish species for Greenland were the most abundant species in both eDNA reads and biomass catch, and interpolation of eDNA abundances between sampling sites showed good correspondence with catch sizes. Environmental DNA sequence reads from the fish assemblages correlated with biomass and abundance data obtained from trawling. Interestingly, the Greenland shark (Somniosus microcephalus showed high abundance of eDNA reads despite only a single specimen being caught, demonstrating the relevance of the eDNA approach for large species that can probably avoid bottom trawls in most cases. Quantitative detection of marine fish using eDNA remains to be tested further to ascertain whether this technique is able to yield credible results for routine application in fisheries. Nevertheless, our study demonstrates that eDNA reads can be used as a qualitative and quantitative proxy for marine fish assemblages in deepwater oceanic

  3. Development of an analytical model for the determination of 60Co in aqueous samples by atomic absorption and gamma spectrometry techniques

    International Nuclear Information System (INIS)

    Solis A, N. A.

    2015-01-01

    The applications of the nuclear energy in industry and medicine generate radioactive wastes that must be isolated and confined in order to limit its spread in the biosphere. These types of wastes are generated in hospitals, industry, research centers and nuclear power plants (during de fuel cycle). The radioactive elements (radionuclides) cannot be destroyed by any known method, either chemical or mechanical. Its final destruction is produced by radioactive decay, which makes them stable isotopes, or nuclear transmutation being bombarded with atomic particles. Consequently, the radioactive waste management is to control the radioactive discharges and reduce to tolerable limits, eliminating of effluents and wastes the radionuclides of interest, concentrating them so they can be stored or evacuated so that later not appear in dangerous concentration in the biosphere. In Mexico, the main generators of radioactive wastes are the nuclear power plant of Laguna Verde in Veracruz, Hospitals of the public and private sector, in addition Instituto Nacional de Investigaciones Nucleares (ININ) some institutes and facilities of the UNAM and Instituto Politecnico Nacional (IPN) and industries among others. The aqueous radioactive wastes, particularly those from the nuclear power plants contain traces of cobalt-60. Currently there is no model or analytical technique for the separation of this radionuclide, so it became necessary to develop an analytical model for separation and facilitate their disposal. In this paper was shown that atomic absorption and gamma spectrometry techniques can separate the active concentration of the inactive, which is important because the total concentration can be associated through direct relationships with the wear of metal parts of the nuclear reactor, since the metal alloys of the same reactor containing a fraction of cobalt. Also this analytical and mathematical model that can be reproducible and applicable to full sets of samples and that this

  4. Online Determination of Sm, Eu and Yb in Environmental Samples by Inductively Coupled Plasma – Optical Emission Spectrometry

    Directory of Open Access Journals (Sweden)

    J. Dilip Kumar

    2007-01-01

    Full Text Available A procedure was developed for the determination of Sm, Eu and Yb in water samples by inductively coupled plasma-optical emission spectrometry (ICP-OES after preconcentration on synthesized 5-(4-pyridyl azo-8-quinolinol supported by Borassus flabellifer inflorescence (BFI. The sorbed element was subsequently eluted with 0.4 M HNO3 and the acid eluates were analyzed by ICP-OES. Under the optimal conditions, Sm, Eu and Yb in aqueous samples were concentrated 100-fold. Recoveries were obtained by the proposed method in the range of 98.6 -99.8%. This method was also applied for the analysis of spiked and natural water samples. The results provide strong evidence to support the hypothesis of an adsorption mechanism.

  5. Effervescence-assisted β-cyclodextrin/attapulgite composite for the in-syringe dispersive solid-phase extraction of pyrethroids in environmental water samples.

    Science.gov (United States)

    Yang, Xiaoling; Zhang, Panjie; Li, Xiaobing; Hu, Lu; Gao, Haixiang; Zhang, Sanbing; Zhou, Wenfeng; Lu, Runhua

    2016-06-01

    In this research, an effervescence-assisted β-cyclodextrin/attapulgite composite (β-CD/ATP) for the in-syringe dispersive solid-phase extraction (EAIS-DSPE) of pyrethroids in environmental samples was developed for the first time. A syringe was used to conduct the extraction procedure and a small amount of β-CD/ATP was dispersed into the solution with the release of carbon dioxide when the effervescent tablet components dissolved in water. Then, the sorbent was recovered using a filter membrane, and the analytes were directly eluted using acetonitrile. In the process, the β-CD/ATP sorbent resulted in an excellent extraction efficiency compared to commercially available sorbents such as C18 and HLB. Moreover, in the extraction procedure, both the β-cyclodextrin inclusion interactions (especially the hydrophobic effects) and the special structure of the ATP contributed to the efficient enrichment of pyrethroids in aqueous media. The amount of β-CD/ATP sorbent, the volume of desorption, the ratio of NaH2PO4/Na2CO3, the volume of the sample, and the pH were screened using a Plackett-Burman design. All factors affecting the procedure were optimized by applying a central composite design. Under the optimized conditions, a good repeatability (RSDs) ranging from 1.7 to 2.3, linearity (2.5-500μgL(-1)), limits of detection (LODs) (0.15-1.03μgL(-1)), and an acceptable recoveries (76.8-86.5%) were achieved. Finally, the proposed method was successfully applied for the determination of pyrethroids in environmental samples including river water, reservoir water and lake water. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Graphene based solid phase extraction combined with ultra high performance liquid chromatography-tandem mass spectrometry for carbamate pesticides analysis in environmental water samples.

    Science.gov (United States)

    Shi, Zhihong; Hu, Junda; Li, Qi; Zhang, Shulan; Liang, Yuhuan; Zhang, Hongyi

    2014-08-15

    In this paper, graphene, a new sorbent material, was synthesized and used for solid-phase extraction (SPE) of the six carbamate pesticides (pirimicarb, baygon, carbaryl, isoprocarb, baycarb and diethofencarb) in environmental water samples. The target analytes can be extracted on the graphene-packed SPE cartridge, and then eluted with acetone. The eluate was collected and dried by high purity nitrogen gas at room temperature. 1mL of 20% (v/v) acetonitrile