WorldWideScience

Sample records for energy mandatory performance

  1. An empirical comparison of voluntary and mandatory building energy performance disclosure outcomes

    International Nuclear Information System (INIS)

    Gabe, Jeremy

    2016-01-01

    In 2010, the federal Australian government mandated the disclosure of energy performance ratings in advertisements for sale or lease of large commercial office properties. Prior to 2010, participation in the rating scheme was voluntary. This study first develops a theoretical model of mandatory disclosure policy effectiveness. Then, with a dataset of all ratings since inception of the voluntary regime in 1999, it tests the expectation that initial voluntary adopters have a greater tendency towards environmental stewardship and are more likely to manage and invest in environmental performance improvements, potentially dampening the effectiveness of mandatory disclosure policy. However, multiple statistical models of certification are unable to reject the null hypothesis that there is no difference in energy efficiency outcomes between the mandatory and voluntary adopters at equivalent stages. For urban policymakers, the extrapolation of voluntary adopter performance appears to be a good – perhaps even conservative – estimation of mandatory energy performance disclosure outcomes. - Highlights: •A theoretical model of building energy disclosure policy effectiveness is proposed. •Mandatory disclosure adopters reduce consumption similar to voluntary adopters. •Mandatory building energy disclosure in Australia has been effective. •Early adopters creating a market for energy retrofits is a likely reason for success.

  2. How effective is mandatory building energy disclosure program in Australia?

    Science.gov (United States)

    Kim, S.; Lim, B. T. H.

    2018-04-01

    Mandatory green building regulations are often considered as the most effective tool to promote better energy efficiency and environmental protection. Nevertheless, its effectiveness compared to the voluntary counterpart has not been fully explored yet. In addressing this gap, this study aims to examine the environmental performance of green building stocks affected by the Australian mandatory building energy disclosure program. To this, this study analysed energy savings and carbon reduction efficiencies using the normalisation approach. The result shows that mandatory energy disclosure program did contribute to the reduction in energy usage and carbon emissions from the affected building stocks. More specifically, affected green building stocks showed a good efficiency especially in carbon reductions. The research results inform policymakers the possible improvement required for the mandatory disclosure program to increase the effectiveness towards dealing with the contemporary environmental issues aroused from the building sector, especially in energy savings perspective.

  3. Construction cost impact analysis of the U.S. Department of Energy mandatory performance standards for new federal commercial and multi-family, high-rise residential buildings

    International Nuclear Information System (INIS)

    Di Massa, F.V.; Hadley, D.L.; Halverson, M.A.

    1993-12-01

    In accordance with federal legislation, the U.S. Department of Energy (DOE) has conducted a project to demonstrate use of its Energy Conservation Voluntary Performance Standards for Commercial and Multi-Family High-Rise Residential Buildings; Mandatory for New Federal Buildings; Interim Rule (referred to in this report as DOE-1993). A key requisite of the legislation requires DOE to develop commercial building energy standards that are cost effective. During the demonstration project, DOE specifically addressed this issue by assessing the impacts of the standards on (1) construction costs, (2) builders (and especially small builders) of multi-family, high-rise buildings, and (3) the ability of low-to moderate-income persons to purchase or rent units in such buildings. This document reports on this project

  4. Mandatory portfolio disclosure, stock liquidity, and mutual fund performance

    OpenAIRE

    Agarwal, Vikas; Mullally, Kevin Andrew; Tang, Yuehua; Yang, Baozhong

    2014-01-01

    We examine the impact of mandatory portfolio disclosure by mutual funds on stock liquidity and fund performance. We develop a model of informed trading with disclosure and test its predictions using the SEC regulation in May 2004 requiring more frequent disclosure. Stocks with higher fund ownership, especially those held by more informed funds or subject to greater information asymmetry, experience larger increases in liquidity after the regulation change. More informed funds, especially thos...

  5. Australia's mandatory renewable energy target (MRET): an assessment

    International Nuclear Information System (INIS)

    Kent, Anthony; Mercer, David

    2006-01-01

    In June 2004, the Prime Minister of Australia, John Howard, released the long-awaited government blueprint for the favoured policy direction for the country's energy sector, Securing Australia's Energy Future. In part this document was a response to a review of the operation of Australia's mandatory renewable energy target (MRET), a regime that started in April 2001. MRET was put under detailed scrutiny from March 2003 onwards by a four-person panel (the Tambling Committee), appointed by the Howard coalition (conservative) government, that received 248 detailed submissions and finally released its findings to the public in January 2004. This paper presents an overview of (i) the range of opinions on MRET presented to the Tambling Inquiry; (ii) the recommendations of that Committee; (iii) the final judgement on MRET enunciated in Securing Australia's Energy Future; and (iv) the response of the States

  6. Performance Sustainability and Integrated Reporting: Empirical Evidence from Mandatory and Voluntary Adoption Contexts

    Directory of Open Access Journals (Sweden)

    Salvatore Loprevite

    2018-04-01

    Full Text Available This paper looks at the topic of regulation of integrated reporting for listed companies, with the aim of contributing to the debate on the usefulness of introducing a mandatory regime, both from the perspective of integrated performance sustainability of companies and from that of relevance of information for providers of financial capital. The study is based on empirical research carried out on a sample composed of companies operating in territories where the adoption of integrated reporting is voluntary (Europe and those operating in a country where adoption is mandatory (South Africa. The research shows that (a in voluntary regimes, levels of integrated performance achieved by companies are higher; (b mandatory regulation produces positive effects on integrated performance levels in the medium term; (c integrated performance indicators are value-relevant, though having different levels of relevance under the two regimes examined.

  7. The effect of mandatory agro-environmental policy on farm environmental performance

    OpenAIRE

    Jaraite, Jurate; Kažukauskas, Andrius

    2011-01-01

    The EU farmers are subject to mandatory cross compliance measures requiring them to meet environmental conditions to be eligible for public support. These obligations reinforce incentives for the farmers to change their behaviour towards the environment. We apply quasi-experimental methods to measure the causal relationship between cross-compliance and farm environmental performance. We find that cross compliance reduced farm fertiliser and pesticide expenditure. This result also holds for fa...

  8. Creating and Implementing a Regularized Monitoring and EnforcementSystem for China's Mandatory Standards and Energy Information Label forAppliances

    Energy Technology Data Exchange (ETDEWEB)

    Lin, Jiang

    2007-03-01

    China has developed a comprehensive program of energy efficiency standards and labels for household appliances. In 1989, China first launched its minimum energy performance standards (MEPS), which are now applied to an extensive list of products. In 1998, China launched a voluntary energy endorsement label, which has grown to cover both energy-saving and water-saving products. And, in 2005, China launched a mandatory energy information label that initially covered two products. CLASP has assisted China in developing 11 minimum energy performance standards (MEPS) for 9 products and endorsement labels for 11 products including: refrigerators; air conditioners; televisions; printers; computers; monitors; fax machines; copiers; DVD/VCD players; external power supplies; and set-top boxes. CLASP has also assisted China in the development of the mandatory energy information label. Increasingly, attention is being placed on maximum energy savings from China's standards and labeling (S&L) efforts in order to meet the recently announced goal of reducing China's energy intensity by 20 percent by 2010 with an interim objective of 4 percent in 2006. China's mandatory standards system is heavily focused on the technical requirements for efficiency performance, but historically, it has lacked administrative and personnel capacity to undertake monitoring and enforcement of these legally binding standards. Similarly, resources for monitoring and enforcement have been quite limited. As a consequence, compliance to both the mandatory standards and the mandatory energy information label is uneven with the potential and likely result of lost energy savings. Thus, a major area for improvement, which could significantly increase overall energy savings, is the creation and implementation of a regularized monitoring system for tracking the compliance to, and enforcement of, mandatory standards and the energy information label in China. CLASP has been working with the China

  9. 10 CFR 435.4 - Energy efficiency performance standard.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Energy efficiency performance standard. 435.4 Section 435.4 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR NEW FEDERAL LOW-RISE RESIDENTIAL BUILDINGS Mandatory Energy Efficiency Standards for Federal Low-Rise Residential...

  10. Poor performance of mandatory nutritional screening of in-hospital patients

    DEFF Research Database (Denmark)

    Geiker, Nina Rica Wium; Larsen, Sisse Marie Hørup; Stender, Steen

    2012-01-01

    Background & aims: Since 2006 it has been mandatory at Copenhagen University Hospital Gentofte to screen all patients for nutritional risk within 24 h of admittance. Audits conducted by department staff estimate that 70-80% of assessments are correctly executed, but the validity of this estimate ...

  11. Residential Energy Performance Metrics

    Directory of Open Access Journals (Sweden)

    Christopher Wright

    2010-06-01

    Full Text Available Techniques for residential energy monitoring are an emerging field that is currently drawing significant attention. This paper is a description of the current efforts to monitor and compare the performance of three solar powered homes built at Missouri University of Science and Technology. The homes are outfitted with an array of sensors and a data logger system to measure and record electricity production, system energy use, internal home temperature and humidity, hot water production, and exterior ambient conditions the houses are experiencing. Data is being collected to measure the performance of the houses, compare to energy modeling programs, design and develop cost effective sensor systems for energy monitoring, and produce a cost effective home control system.

  12. Energy performance assessment methodology

    Energy Technology Data Exchange (ETDEWEB)

    Platzer, W.J. [Fraunhofer Inst. for Solar Energy Systems, Freiburg (Germany)

    2006-01-15

    The energy performance of buildings are intimately connected to the energy performance of building envelopes. The better we understand the relation between the quality of the envelope and the energy consumption of the building, the better we can improve both. We have to consider not only heating but all service energies related to the human comfort in the building, such as cooling, ventilation, lighting as well. The complexity coming from this embracing approach is not to be underestimated. It is less and less possible to realted simple characteristic performance indicators of building envelopes (such as the U-value) to the overall energy performance. On the one hand much more paramters (e.g. light transmittance) come into the picture we have to assess the product quality in a multidimensional world. Secondly buildings more and more have to work on a narrow optimum: For an old, badly insulated building all solar gains are useful for a high-performance building with very good insulation and heat recovery systems in the ventilation overheating becomes more likely. Thus we have to control the solar gains, and sometimes we need high gains, sometimes low ones. And thirdly we see that the technology within the building and the user patterns and interactions as well influence the performance of a building envelope. The aim of this project within IEA Task27 was to improve our knowledge on the complex situation and also to give a principal approach how to assess the performance of the building envelope. The participants have contributed to this aim not pretending that we have reached the end. (au)

  13. A (giant) void is not mandatory to explain away dark energy with a Lemaître-Tolman model

    Science.gov (United States)

    Célérier, M.-N.; Bolejko, K.; Krasiński, A.

    2010-07-01

    Context. Lemaître-Tolman (L-T) toy models with a central observer have been used to study the effect of large scale inhomogeneities on the SN Ia dimming. Claims that a giant void is mandatory to explain away dark energy in this framework are currently dominating. Aims: Our aim is to show that L-T models exist that reproduce a few features of the ΛCDM model, but do not contain the giant cosmic void. Methods: We propose to use two sets of data - the angular diameter distance together with the redshift-space mass-density and the angular diameter distance together with the expansion rate - both defined on the past null cone as functions of the redshift. We assume that these functions are of the same form as in the ΛCDM model. Using the Mustapha-Hellaby-Ellis algorithm, we numerically transform these initial data into the usual two L-T arbitrary functions and solve the evolution equation to calculate the mass distribution in spacetime. Results: For both models, we find that the current density profile does not exhibit a giant void, but rather a giant hump. However, this hump is not directly observable, since it is in a spacelike relation to a present observer. Conclusions: The alleged existence of the giant void was a consequence of the L-T models used earlier because their generality was limited a priori by needless simplifying assumptions, like, for example, the bang-time function being constant. Instead, one can feed any mass distribution or expansion rate history on the past light cone as initial data to the L-T evolution equation. When a fully general L-T metric is used, the giant void is not implied.

  14. Advanced Performance Hydraulic Wind Energy

    Science.gov (United States)

    Jones, Jack A.; Bruce, Allan; Lam, Adrienne S.

    2013-01-01

    The Jet Propulsion Laboratory, California Institute of Technology, has developed a novel advanced hydraulic wind energy design, which has up to 23% performance improvement over conventional wind turbine and conventional hydraulic wind energy systems with 5 m/sec winds. It also has significant cost advantages with levelized costs equal to coal (after carbon tax rebate). The design is equally applicable to tidal energy systems and has passed preliminary laboratory proof-of-performance tests, as funded by the Department of Energy.

  15. Energy Performance of Buildings

    DEFF Research Database (Denmark)

    Heiselberg, Per

    2007-01-01

    "Sustainable development" has been defined best by the Brundtland Commission as "development that meets the needs of the present without compromising the ability of future generations to meet their own needs". Adequate and affordable energy supplies have been key to economic development and are c......"Sustainable development" has been defined best by the Brundtland Commission as "development that meets the needs of the present without compromising the ability of future generations to meet their own needs". Adequate and affordable energy supplies have been key to economic development...... and are central to improving social and economic well- being, and human welfare and raising living standards. Even if energy is essential for development, it is only a means to an end. The end is good health, high living standards, a sustainable economy and a clean environment. The European Climate change...... programme (ECCP) was established in June 2000 to help identify the most environmentally cost-effective measures enabling the EU to meet its target under the Kyoto Protocol, namely an 8% reduction in greenhouse gas emissions from 1990 levels by 2012. Energy use in buildings accounts for almost half of all CO...

  16. Mandatory School Uniforms.

    Science.gov (United States)

    Cohn, Carl A.

    1996-01-01

    Shortly after implementing a mandatory school uniform policy, the Long Beach (California) Public Schools can boast 99% compliance and a substantial reduction in school crime. The uniforms can't be confused with gang colors, save parents money, and help identify outsiders. A sidebar lists ingredients for a mandatory uniform policy. (MLH)

  17. Windows with improved energy performance

    DEFF Research Database (Denmark)

    Noyé, Peter Anders; Laustsen, Jacob Birck; Svendsen, Svend

    2002-01-01

    According to the Danish energy protocol, Energy 21, one of the goals with highest priority is to reduce the CO2-emission. Energy consumption for domestic heating is a major contributor to the CO2-emission; hence one of the primary efforts to reach the goal is by saving energy in the households...... performances. During the last 20 years the U-value of the glazing part of windows has been improved considerably, but the frame part has not followed the same development with respect to energy performance. Therefore an increasingly large part of the total heat loss through windows is relating to the frame...... part, for which reason, as far as energy efficiency and total economy are concerned, it has become more interesting to further develop frame structures. Traditionally, the energy performance of windows has primarily been characterised by the heat loss coefficient, U-value. However as the heat loss has...

  18. Windows with improved energy performances

    DEFF Research Database (Denmark)

    Laustsen, Jacob Birck; Svendsen, Svend

    2003-01-01

    Heat loss through windows represents a considerable part of the total heat loss from houses. However, apart from providing daylight access and view, windows offer a unique potential for solar gain to be exploited during the heating season. Until now valuation of the energy performance of windows...... has primary focused on the heat loss coefficient, U-value. However, as the U-value, especially for the glazing part, has improved considerably during the last years, the total solar energy transmittance, g-value, has become equally important to the total energy performance of windows. Improved energy...... resulted in a window with a positive net energy gain (in short the Net Gain Window), which means that it contributes to the space heating of the building. All improvements are based on existing technology and manufacturing methods. The results from this work show that the energy performances of windows can...

  19. Energy performance evaluation of AAC

    Science.gov (United States)

    Aybek, Hulya

    The U.S. building industry constitutes the largest consumer of energy (i.e., electricity, natural gas, petroleum) in the world. The building sector uses almost 41 percent of the primary energy and approximately 72 percent of the available electricity in the United States. As global energy-generating resources are being depleted at exponential rates, the amount of energy consumed and wasted cannot be ignored. Professionals concerned about the environment have placed a high priority on finding solutions that reduce energy consumption while maintaining occupant comfort. Sustainable design and the judicious combination of building materials comprise one solution to this problem. A future including sustainable energy may result from using energy simulation software to accurately estimate energy consumption and from applying building materials that achieve the potential results derived through simulation analysis. Energy-modeling tools assist professionals with making informed decisions about energy performance during the early planning phases of a design project, such as determining the most advantageous combination of building materials, choosing mechanical systems, and determining building orientation on the site. By implementing energy simulation software to estimate the effect of these factors on the energy consumption of a building, designers can make adjustments to their designs during the design phase when the effect on cost is minimal. The primary objective of this research consisted of identifying a method with which to properly select energy-efficient building materials and involved evaluating the potential of these materials to earn LEED credits when properly applied to a structure. In addition, this objective included establishing a framework that provides suggestions for improvements to currently available simulation software that enhance the viability of the estimates concerning energy efficiency and the achievements of LEED credits. The primary objective

  20. Setting effective mandatory energy efficiency standards and labelling regulations: A review of best practices in the Asia Pacific region

    International Nuclear Information System (INIS)

    Shi, Xunpeng

    2014-01-01

    Highlights: • S and L regulations are needed to materialize the various benefits of energy efficiency. • S and L regulations can appear in various formats as in the Asia–Pacific region. • Effective regime has to be clear, authoritative, open, and enforceable. • Clear policy, customisation, inclusiveness, transparency and flexibility are desirable. - Abstract: This paper attempts to inform policy makers and legislators on how to set energy efficiency standards and labelling (S and L) regulations. It draws lessons from the literature on S and L regulations in the Asia–Pacific region and from practical experience in drafting the S and L regulations for Brunei Darussalam. The paper proposes necessary components for effective S and L regulations, as follows: clear liabilities, authoritative administration, open principles for technical systems, and enforceable mechanisms. It also recommends some key issues in good practice toward effective S and L regulations, such as policy making in advance, customised legislation, inclusive and transparent legislative procedure, and flexibility in the legislation

  1. Issues - III. Renewable energies and financial issues - The organisation of a renewable energy sector: the supply in wood-fuel in Auvergne; profitable ecology: which incentive financial and tax tools in favour of renewable energies?; the mechanism of mandatory purchase of electricity production: a precarious support mechanism

    International Nuclear Information System (INIS)

    Amblard, Laurence; Taverne, Marie; Guerra, Fabien; Rouge, Sandra; Gelas, Helene

    2012-01-01

    A first article reports the results of an investigation of the organisation of wood-fuel supply in the French region of Auvergne (presentation of the supply chain analysis, use of the transaction cost theory, factors affecting organisational choices within supply chains). The second article presents and comments the various incentive financial and tax measures in favour of renewable energies (State tax incentives for companies and for individuals, local incentives, and financial incentives). The third article outlines the precarious legal character of the mechanism of mandatory purchase of electricity production, as well as the precarious will of the Government regarding this mandatory purchase

  2. Environment, energy, and economic performance

    Energy Technology Data Exchange (ETDEWEB)

    Oberndorfer, Ulrich

    2009-09-25

    This thesis analyzes the relationship between environmental regulation as well as energy market developments on the one hand, and economic performance on the other. Due to its economic effects environmental regulation is controversially disputed. The thesis shows, however, that the economic impacts of the recently adopted climate policy in Europe, namely of the implementation of the European Union Emission Trading Scheme, have been modest at most. Consistent with economic theory, the low stringency of this regulatory measure that is aimed at combating man-made climate change is identified as one important driver of this result. Moreover, results presented in this thesis also indicate the important role which the political economy plays for the design of environmental regulation in general. These mechanisms are shown to be a driver of the low stringency and, consequently, of the small economic effects during the first phase of the European Union Emission Trading Scheme. The thesis highlights the role of investment stimulation if the goal of environmental regulation is not only the protection of the environment, but also the compatibility with economic goals. This thesis also provides new insights into the role of energy market developments for the economy. In this respect, the relevance of the EU carbon market for the financial market performance of European electricity generators is shown. Besides, this thesis particularly demonstrates the paramount importance of oil market developments for the economy as a whole. It suggests that amongst all natural resources, oil is the most relevant one to the pricing of Eurozone energy stocks. It is also shown that besides oil prices, oil volatility plays an important role for stock market development. Finally, the thesis highlights the relevance of oil market developments to the overall economy, in showing that unemployment in Germany is strongly affected by oil price shocks. In this respect, it also opposes claims that the

  3. The effect of energy performance regulations on energy consumption

    NARCIS (Netherlands)

    Guerra-Santin, O.; Itard, L.

    2012-01-01

    Governments have developed energy performance regulations in order to lower energy consumption in the housing stock. Most of these regulations are based on the thermal quality of the buildings. In the Netherlands, the energy efficiency for new buildings is expressed as the EPC (energy performance

  4. Energy performance of windows based on the net energy gain

    DEFF Research Database (Denmark)

    Svendsen, Svend; Kragh, Jesper; Laustsen, Jacob Birck

    2005-01-01

    The paper presents a new method to set up energy performance requirements and energy classes for windows of all dimensions and configurations. The net energy gain of windows is the solar gain minus the heat loss integrated over the heating season. The net energy gain can be calculated for one...... be expressed as a function of two parameters representing the energy performance and two parameters representing the geometry of the window. The two energy performance parameters are the net energy gain per area of the glazing unit and the sum of the heat losses through the frame and the assembly per length...... of the frame. The two geometry numbers are the area of the glazing unit relative to the window area and the length of the frame profiles relative to the window area. Requirements and classes for the energy performance of the window can be given by assigning values to the two energy performance parameters...

  5. How to estimate realistic energy savings in Energy Performance Certificates

    DEFF Research Database (Denmark)

    Wittchen, Kim Bjarne; Altmann, Nagmeh; Berecová, Monika

    Given the fact that most MS use fixed or other kinds of default values as boundary condition input for energy performance calculations, it is not surprising that the calculated energy performance differs from the measured energy consumption. As a consequence, the calculated energy savings due...... stationary calculation tools using monthly average values. The optimum solution for energy performance certificates and calculating realistic energy savings is to have two calculations. One calculation, using default values to calculate the label itself, and one with actual input parameters for calculating...... energy performance before and after implementing energy saving measures. Actual values though, may be difficult to identify, so there is a need to make adaptations to reality easy. Even if actual values are available, there are still issues that cause calculated energy savings to differ from the obtained...

  6. Energy Savings Performance Contract Energy Sales Agreement Toolkit

    Energy Technology Data Exchange (ETDEWEB)

    None

    2017-08-14

    FEMP developed the Energy Savings Performance Contracting Energy Sales Agreement (ESPC ESA) Toolkit to provide federal agency contracting officers and other acquisition team members with information that will facilitate the timely execution of ESPC ESA projects.

  7. Mandatory IFRS adoption and executive compensation: Evidence from China

    OpenAIRE

    Qingchuan Hou; Qinglu Jin; Lanfang Wang

    2014-01-01

    This study investigates how the mandatory adoption of International Financial Reporting Standards (IFRS) affects the contractual benefits of using accounting information to determine executive compensation in China. After controlling for firm and corporate governance characteristics, we find strong evidence supporting the positive role of mandatory IFRS adoption on the accounting-based performance sensitivity of executive compensation. Subsample analysis suggests that improvements in accounti...

  8. Developing an Energy Performance Modeling Startup Kit

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2012-10-01

    In 2011, the NAHB Research Center began assessing the needs and motivations of residential remodelers regarding energy performance remodeling. This report outlines: the current remodeling industry and the role of energy efficiency; gaps and barriers to adding energy efficiency into remodeling; and support needs of professional remodelers to increase sales and projects involving improving home energy efficiency.

  9. Performance Limits of Communication with Energy Harvesting

    KAUST Repository

    Znaidi, Mohamed Ridha

    2016-01-01

    In energy harvesting communications, the transmitters have to adapt transmission to the availability of energy harvested during communication. The performance of the transmission depends on the channel conditions which vary randomly due to mobility

  10. Performance profiles of major energy producers 1994

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-02-01

    Performance Profiles of Major Energy Producers 1994 is the eighteenth annual report of the Energy Information Administration`s (EIA) Financial Reporting System (FRS). The report examines financial and operating developments in energy markets, with particular reference to the 24 major U.S. energy companies required to report annually on Form EIA-28. Financial information is reported by major lines of business, including oil and gas production, petroleum refining and marketing, other energy operations, and nonenergy businesses. Financial and operating results are presented in the context of energy market developments with a view toward identifying changing corporate strategies and measuring the performance of ongoing operations both in the United States and abroad.

  11. The European Energy Performance of Buildings Directive

    DEFF Research Database (Denmark)

    Petersen, Steffen; Hviid, Christian Anker

    This paper investigates the actual energy use for building operation with the calculated energy use according to the Danish implementation of the European Energy Performance of Buildings Directive (EPBD). This is important to various stakeholders in the building industry as the calculated energy...... performance is used for estimating investment security, operating budgets and for policy making. A case study shows that the actual and calculated energy use is practically the same in an average scenario. In the worst-case uncertainty scenario, the actual energy use is 20 % higher than the corrected...

  12. Market response to the public display of energy performance rating at property sales

    International Nuclear Information System (INIS)

    Jensen, Ole Michael; Hansen, Anders Rhiger; Kragh, Jesper

    2016-01-01

    Energy labels have generally received positive response from consumers and have moved the market for white goods and cars in the direction of more energy-efficient products. On the real estate market, it was expected that an energy label, rating the energy performance of a property based on a national energy performance certificate (EPC) might receive similar response. However, in Denmark no response to the energy performance rating was observed for 15 years. This was a surprise considering that Denmark was the first country to implement an A to G rating of the energy performance of buildings. A statistical examination of data on property sales prices and energy performance ratings was carried out. All relevant property transaction data from 2007 till 2012 were examined and they showed that energy performance ratings had an impact on property sales prices. However, before June 2010, the impact was modest, whereas after June 2010 the impact of energy performance ratings on property sales prices increased significantly as a result of an EU requirement to display the energy performance rating in connection with property sales. On this background, it was concluded that a public display of the energy performance rating is fundamental for market response. - Highlights: •Energy performance ratings of buildings have an impact on property sales prices. •A statistical examination shows that since 2010 sales prices reflect energy performance. •Mandatory display of the rating prescribed by EU Directive was decisive. •The positive market response will be an incentive for energy upgrading of the property.

  13. Commercial Buildings Energy Performance within Context

    DEFF Research Database (Denmark)

    Lazarova-Molnar, Sanja; Kjærgaard, Mikkel Baun; Shaker, Hamid Reza

    2015-01-01

    Existing commercial buildings represent a challenge in the energy efficiency domain. Energy efficiency of a building, very often equalized to a building’s performance should not be observed as a standalone issue. For commercial buildings, energy efficiency needs to be observed and assessed within...

  14. Performance profiles of major energy producers 1989

    Energy Technology Data Exchange (ETDEWEB)

    1991-01-23

    Performance Profiles of Major Energy Producers 1989 is the thirteenth annual report of the Energy Information Administration's (EIA) Financial Reporting System (FRS). The report examines financial and operating developments, with particular reference to the 23 major energy companies (the FRS companies'') required to report annually on Form EIA-28. Financial information is reported by major lines of business including oil and gas production, petroleum refining and marketing, and other energy operations. Domestic and international operations are examined separately in this report. It also traces key developments affecting the financial performance of major energy companies in 1989, as well as review of important trends.

  15. Performance profiles of major energy producers, 1991

    International Nuclear Information System (INIS)

    1992-01-01

    Performance Profiles of Major Energy Producers 1991 is the fifteenth annual report of the Energy Information Administration's (EIA) Financial Reporting System (FRS). The report examines financial and operating developments, with particular reference to the 23 major energy companies (the FRS companies) required to report annually on Form EIA-28. It also traces key developments affecting the financial performance of major energy companies in 1991, as well as reviews important trends. Financial information is reported by major lines of business including oil and gas production, petroleum refining and marketing, and other energy operations. Domestic and international operations are examined separately in this report

  16. Procedure to Measure Indoor Lighting Energy Performance

    Energy Technology Data Exchange (ETDEWEB)

    Deru, M.; Blair, N.; Torcellini, P.

    2005-10-01

    This document provides standard definitions of performance metrics and methods to determine them for the energy performance of building interior lighting systems. It can be used for existing buildings and for proposed buildings. The primary users for whom these documents are intended are building energy analysts and technicians who design, install, and operate data acquisition systems, and who analyze and report building energy performance data. Typical results from the use of this procedure are the monthly and annual energy used for lighting, energy savings from occupancy or daylighting controls, and the percent of the total building energy use that is used by the lighting system. The document is not specifically intended for retrofit applications. However, it does complement Measurement and Verification protocols that do not provide detailed performance metrics or measurement procedures.

  17. Energy policy and energy market performance: The Argentinean case

    International Nuclear Information System (INIS)

    Recalde, Marina

    2011-01-01

    In the early 1990s Argentina liberalized and privatized the energy system, trending to a total market oriented system and abandoning the use of energy policy. Since 2004, as a result of a boom in energy demand and constrains in energy supply, Argentina has gone through an energy problem mainly related to natural gas and electricity, which derived in energy shutdowns. In this frame, this study explores the role of energy policy and institutions in Argentina, with the aim of discussing whether it has been properly used to contrast the observed lack of coordination between fossil energy reserves management and the demand of fuels in power generation. The results of the analysis enhance the relevance of regulatory and control authorities, as well as the active use of long run energy policy for the energy system performance in order to avoid coordination failures between subsectors of the system. The relevance of energy consumption for the development process, and the particular characteristics of energy systems require a wide planning perspective. - Highlights: → This paper examines some aspects of the performance of the Argentinean energy system and energy policy. → There is a lack of coordination between fossil energy reserves management and electricity demand. → It is required an improvement of the regulatory framework, and an active role of the regulatory authorities. → A better planning for electricity supply and strengthening aspects related to the linking with other energy chains. → Promoting a systematic exploitation of NG and oil reserves' and increasing the share of RETs in the energy mix.

  18. Policy Pathways: Energy Performance Certification of Buildings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    Improving energy efficiency is one of the most effective measures to address energy security, climate change and economic objectives. The Policy Pathways series can help countries capture this potential by assisting with the implementation of the 25 energy efficiency policy recommendations that were published by the International Energy Agency (IEA) in 2008. This policy pathway on energy performance certification of buildings is the second in the series. It aims to provide a 'how-to' guide to policy makers and relevant stakeholders on the essential elements in implementing energy performance certification of buildings programmes. Energy performance certification of buildings is a way to rate the energy efficiency of individual buildings -- whether they be residential, commercial or public. It is a key policy instrument that can assist governments in reducing energy consumption in buildings. This policy pathway showcases experiences from countries around the world to show examples of good practice and delivers a pathway of ten critical steps to implement energy performance certification of buildings programmes.

  19. Performance profiles of major energy producers 1993

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-01-01

    Performance Profiles of Major Energy Producers 1993 is the seventeenth annual report of the Energy Information Administration`s (EIA) Financial Reporting System (FRS). The report examines financial and operating developments in energy markets, with particular reference to the 25 major US energy companies required to report annually on Form EIA-28. Financial information is reported by major liens of business, including oil and gas production, petroleum refining and marketing, other energy operations, and nonenergy businesses. Financial and operating results are presented in the context of energy market developments with a view toward identifying changing corporate strategies and measuring the performance of ongoing operations both in the US and abroad. This year`s report analyzes financial and operating developments for 1993 (Part 1: Developments in 1993) and also reviews key developments during the 20 years following the Arab Oil Embargo of 1973--1974 (Part 2: Major Energy Company Strategies Since the Arab Oil Embargo). 49 figs., 104 tabs.

  20. Performance profiles of major energy producers 1992

    International Nuclear Information System (INIS)

    1994-01-01

    Performance Profiles of Major Energy Producers 1992 is the sixteenth annual report of the Energy Information Administration's (EIA) Financial Reporting System (FRS). The report examines financial and operating developments, with particular reference to the 25 major energy companies (the FRS companies) required to report annually on Form EIA-28. Financial information is reported by major lines of business, including oil and gas production, petroleum refining and marketing, and other energy operations. Domestic and international operations are examined separately in this report. The data are presented in the context of key energy market developments with a view toward identifying changing strategies of corporate development and measuring the apparent success of current ongoing operations

  1. Development of a Mobile Application for Building Energy Prediction Using Performance Prediction Model

    Directory of Open Access Journals (Sweden)

    Yu-Ri Kim

    2016-03-01

    Full Text Available Recently, the Korean government has enforced disclosure of building energy performance, so that such information can help owners and prospective buyers to make suitable investment plans. Such a building energy performance policy of the government makes it mandatory for the building owners to obtain engineering audits and thereby evaluate the energy performance levels of their buildings. However, to calculate energy performance levels (i.e., asset rating methodology, a qualified expert needs to have access to at least the full project documentation and/or conduct an on-site inspection of the buildings. Energy performance certification costs a lot of time and money. Moreover, the database of certified buildings is still actually quite small. A need, therefore, is increasing for a simplified and user-friendly energy performance prediction tool for non-specialists. Also, a database which allows building owners and users to compare best practices is required. In this regard, the current study developed a simplified performance prediction model through experimental design, energy simulations and ANOVA (analysis of variance. Furthermore, using the new prediction model, a related mobile application was also developed.

  2. Comparing Voluntary and Mandatory Gameplay

    Directory of Open Access Journals (Sweden)

    Esther Kuindersma

    2016-09-01

    Full Text Available Gameplay is commonly considered to be a voluntary activity. Game designers generally believe that voluntary gameplay is essentially different from mandatory gameplay. Such a belief may be a challenge for serious games, as instruction is usually mandatory. The article describes the outcomes of two experiments on the impact of voluntariness on the learning effect and enjoyment of a serious game. In the first experiment freedom of choosing to play a serious game was studied, with participants who had volunteered to participate. The results suggested that, contrary to the opinion of many game designers, being required to play a serious game does not automatically take the fun out of the game. The second experiment had voluntary participants and mandatory participants, who had to participate as part of a homework assignment. The outcomes show that mandatory participants enjoyed the game as much as the voluntary participants, even if they had to play the game for a minimum required time. These studies indicate that mandatory gameplay does not reduce enjoyment and learning effect.

  3. Maintaining a Viable Energy Savings Performance Contract

    National Research Council Canada - National Science Library

    Weber, Katherine L; Huckeby, Michael A

    2005-01-01

    Substantial amounts of information are available on Energy Savings Performance Contract award requirements, measurement, and verification, but we have found very little information on the day-to-day...

  4. Incorporating Non-energy Benefits into Energy Savings Performance Contracts

    Energy Technology Data Exchange (ETDEWEB)

    Larsen, Peter; Goldman, Charles; Gilligan, Donald; Singer, Terry

    2012-06-01

    This paper evaluates the issue of non-energy benefits within the context of the U.S. energy services company (ESCO) industry?a growing industry comprised of companies that provide energy savings and other benefits to customers through the use of performance-based contracting. Recent analysis has found that ESCO projects in the public/institutional sector, especially at K-12 schools, are using performance-based contracting, at the behest of the customers, to partially -- but not fully -- offset substantial accumulated deferred maintenance needs (e.g., asbestos removal, wiring) and measures that have very long paybacks (roof replacement). This trend is affecting the traditional economic measures policymakers use to evaluate success on a benefit to cost basis. Moreover, the value of non-energy benefits which can offset some or all of the cost of the non-energy measures -- including operations and maintenance (O&M) savings, avoided capital costs, and tradable pollution emissions allowances-- are not always incorporated into a formal cost-effectiveness analysis of ESCO projects. Nonenergy benefits are clearly important to customers, but state and federal laws that govern the acceptance of these types of benefits for ESCO projects vary widely (i.e., 0-100percent of allowable savings can come from one or more non-energy categories). Clear and consistent guidance on what types of savings are recognized in Energy Savings agreements under performance contracts is necessary, particularly where customers are searching for deep energy efficiency gains in the building sector.

  5. Architectural design and energy performance; Conception architecturale et performance energetique

    Energy Technology Data Exchange (ETDEWEB)

    Beaud, Ph. [Agence de l' Environnement et de la Maitrise de l' Energie, (ADEME), 06 - Valbonne (France); Pouget, A. [Bureau Etude Thermique, 75 - Paris (France); Sesolis, B. [TRIBU, 75 - Paris (France)] [and others

    2000-07-01

    This day was organized around the energy performance of the architecture in three parts. A first time dealt with the design of new buildings and private houses. Simulation tools for the energy optimization and practice of design are discussed. The second part was devoted to the new 2000 regulation with an open discussion on the regulatory costs. The last part forecasted the evolution until 2015 taking into account the french program of fight against the greenhouse effect, the limitation of the air conditioning consumption and the definition of a quality label concerning the energy performances. (A.L.B.)

  6. Energy performance indicator report: fluid milk plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    In Canada, the dairy sector consumes significant amounts of energy and is looking for new ways of saving energy. The aim of this study, performed by the Competitive Analysis Centre Inc., was to find novel energy savings ideas for fluid milk plants. For this purpose, the energy consumption of 17 fluid milk plants, which accounts for over 50% of total Canadian output, was analyzed; first, at the plant level, and then by 8 categories at the sub-plant level in order to develop benchmarks that could be applied at both these levels. The paper provides background information on Canada's fluid milk sector and outlines the methodology used to develop and apply energy efficiency measures in the sector; the study findings are also presented. This report found that the energy consumption of the Canadian fluid milk sector could be lowered by applying the energy saving proposals developed herein.

  7. BUILDING DESIGN INFLUENCE ON THE ENERGY PERFORMANCE

    Directory of Open Access Journals (Sweden)

    Moga Ligia

    2015-05-01

    Full Text Available Energy efficient design is a high priority in the national energy strategy of European countries considering the latest requirements of the European Directive on the Energy Performance of Buildings. The residential sector is responsible for a significant quantity of energy consumptions from the total amount of consumptions on a worldwide level. In residential building most of the energy consumptions are given mainly by heating, domestic hot water and lighting. Retrofitting the existing building stock offers great opportunities for reducing global energy consumptions and greenhouse gas emissions. The first part of the paper will address the need of thermal and energy retrofit of existing buildings. The second part will provide an overview on how various variables can influence the energy performance of a building that is placed in all four climatic zones from Romania. The paper is useful for specialist and designers from the construction field in understanding that buildings behave differently from the energy point of view in different climatic regions, even if the building characteristic remain the same.

  8. Performance profiles of major energy producers, 1997

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-01-01

    The energy industry generally and petroleum and natural gas operations in particular are frequently reacting to a variety of unsettling forces. Falling oil prices, economic upswings, currency devaluations, increasingly rigorous environmental quality standards, deregulation of electricity markets, and continued advances in exploration and production technology were among the challenges and opportunities to the industry in 1997. To analyze the extent to which these and other developments have affected energy industry financial and operating performance, strategies, and industry structure, the Energy Information Administration (EIA) maintains the Financial Reporting Systems (FRS). Through Form EIA-28, major US energy companies annually report to the FRS. Financial and operating information is reported by major lines of business, including oil and gas production (upstream), petroleum refining and marketing (downstream), other energy operations, and nonenergy business. Performance Profiles of Major Producers 1997 examines the interplays of energy markets, companies` strategies, and government policies (in 1997 and in historical context) that gave rise to the results given here. The report also analyzes other key aspects of energy company financial performance as seen through the multifaceted lens provided by the FRS data and complementary data for industry overall. 41 figs., 77 tabs.

  9. Automatic Energy Schemes for High Performance Applications

    Energy Technology Data Exchange (ETDEWEB)

    Sundriyal, Vaibhav [Iowa State Univ., Ames, IA (United States)

    2013-01-01

    Although high-performance computing traditionally focuses on the efficient execution of large-scale applications, both energy and power have become critical concerns when approaching exascale. Drastic increases in the power consumption of supercomputers affect significantly their operating costs and failure rates. In modern microprocessor architectures, equipped with dynamic voltage and frequency scaling (DVFS) and CPU clock modulation (throttling), the power consumption may be controlled in software. Additionally, network interconnect, such as Infiniband, may be exploited to maximize energy savings while the application performance loss and frequency switching overheads must be carefully balanced. This work first studies two important collective communication operations, all-to-all and allgather and proposes energy saving strategies on the per-call basis. Next, it targets point-to-point communications to group them into phases and apply frequency scaling to them to save energy by exploiting the architectural and communication stalls. Finally, it proposes an automatic runtime system which combines both collective and point-to-point communications into phases, and applies throttling to them apart from DVFS to maximize energy savings. The experimental results are presented for NAS parallel benchmark problems as well as for the realistic parallel electronic structure calculations performed by the widely used quantum chemistry package GAMESS. Close to the maximum energy savings were obtained with a substantially low performance loss on the given platform.

  10. Performance profiles of major energy producers 1992

    Energy Technology Data Exchange (ETDEWEB)

    1994-01-13

    Performance Profiles of Major Energy Producers 1992 is the sixteenth annual report of the Energy Information Administration`s (EIA) Financial Reporting System (FRS). The report examines financial and operating developments, with particular reference to the 25 major energy companies (the FRS companies) required to report annually on Form EIA-28. Financial information is reported by major lines of business, including oil and gas production, petroleum refining and marketing, and other energy operations. Domestic and international operations are examined separately in this report. The data are presented in the context of key energy market developments with a view toward identifying changing strategies of corporate development and measuring the apparent success of current ongoing operations.

  11. Performance Evaluation of Wave Energy Converters

    DEFF Research Database (Denmark)

    Pecher, Arthur

    Ocean waves provide a sustainable, power-dense, predictable and widely available source of energy that could provide about 10 % of worlds energy needs. While research into waveenergy has been undertaken for decades, a significant increase in related activities has been seen in the recent years......, with more than 150 concepts currently being developed worldwide. Wave energy conversion concepts can be of many kinds, as the energy in the waves can be absorbed in many different ways. However, each concept is expected to require a thorough development process, involving different phases and prototypes....... Guidelines for the development of wave energy converters recommend the use of different prototypes, having different sizes, which have to perform tank tests or sea trials. Thisimplicates the need of different testing environment, which shifts from being controllable to uncontrollable with the development...

  12. Performance Evaluation of Wave Energy Converters

    DEFF Research Database (Denmark)

    Pecher, Arthur

    . Guidelines for the development of wave energy converters recommend the use of different prototypes, having different sizes, which have to perform tank tests or sea trials. This implicates the need of different testing environment, which shifts from being controllable to uncontrollable with the development......, with more than 150 concepts currently being developed worldwide. Wave energy conversion concepts can be of many kinds, as the energy in the waves can be absorbed in many different ways. However, each concept is expected to require a thorough development process, involving different phases and prototypes...

  13. Developing an Energy Performance Modeling Startup Kit

    Energy Technology Data Exchange (ETDEWEB)

    Wood, A.

    2012-10-01

    In 2011, the NAHB Research Center began the first part of the multi-year effort by assessing the needs and motivations of residential remodelers regarding energy performance remodeling. The scope is multifaceted - all perspectives will be sought related to remodeling firms ranging in size from small-scale, sole proprietor to national. This will allow the Research Center to gain a deeper understanding of the remodeling and energy retrofit business and the needs of contractors when offering energy upgrade services. To determine the gaps and the motivation for energy performance remodeling, the NAHB Research Center conducted (1) an initial series of focus groups with remodelers at the 2011 International Builders' Show, (2) a second series of focus groups with remodelers at the NAHB Research Center in conjunction with the NAHB Spring Board meeting in DC, and (3) quantitative market research with remodelers based on the findings from the focus groups. The goal was threefold, to: Understand the current remodeling industry and the role of energy efficiency; Identify the gaps and barriers to adding energy efficiency into remodeling; and Quantify and prioritize the support needs of professional remodelers to increase sales and projects involving improving home energy efficiency. This report outlines all three of these tasks with remodelers.

  14. Performance Analysis: Control of Hazardous Energy

    Energy Technology Data Exchange (ETDEWEB)

    De Grange, Connie E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Freeman, Jeff W. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Kerr, Christine E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2010-10-06

    LLNL experienced 26 occurrences related to the control of hazardous energy from January 1, 2008 through August 2010. These occurrences were 17% of the total number of reported occurrences during this 32-month period. The Performance Analysis and Reporting Section of the Contractor Assurance Office (CAO) routinely analyzes reported occurrences and issues looking for patterns that may indicate changes in LLNL’s performance and early indications of performance trends. It became apparent through these analyses that LLNL might have experienced a change in the control of hazardous energy and that these occurrences should be analyzed in more detail to determine if the perceived change in performance was real, whether that change is significant and if the causes of the occurrences are similar. This report documents the results of this more detailed analysis.

  15. Energy sustainability performance of the regional economy

    Directory of Open Access Journals (Sweden)

    N. I. Danilov

    2005-03-01

    Full Text Available The results of the study of the dynamics of energy intensity of gross regional product of the Sverdlovsk region for the period 1996 - 2003 years. and projections for the period up to 2015. The principal possibility of growth performance of the regional economy, without a significant increase in the consumption of primary fuel.

  16. Cost optimal levels for energy performance requirements

    DEFF Research Database (Denmark)

    Thomsen, Kirsten Engelund; Aggerholm, Søren; Kluttig-Erhorn, Heike

    This report summarises the work done within the Concerted Action EPBD from December 2010 to April 2011 in order to feed into the European Commission's proposal for a common European procedure for a Cost-Optimal methodology under the Directive on the Energy Performance of Buildings (recast) 2010/3...

  17. Raising the energy performance of historical dwellings

    NARCIS (Netherlands)

    van Krugten, L.T.F.; Hermans, L.M.C.; Havinga, L.C.; Pereira Roders, A.R.; Schellen, H.L.

    2016-01-01

    Purpose: Earlier studies assume that historical dwellings and post-war dwellings in particular, are less sustainable than modern dwellings, justifying its demolition. Over time, historical buildings have been transformed and their energy performance improved. However, there is little known on the

  18. The Business Value of Superior Energy Performance

    Energy Technology Data Exchange (ETDEWEB)

    McKane, Aimee; Scheihing, Paul; Evans, Tracy; Glatt, Sandy; Meffert, William

    2015-08-04

    Industrial facilities participating in the U.S. Department of Energy’s (US DOE) Superior Energy Performance (SEP) program are finding that it provides them with significant business value. This value starts with the implementation of ISO 50001-Energy management system standard, which provides an internationally-relevant framework for integration of energy management into an organization’s business processes. The resulting structure emphasizes effective use of available data and supports continual improvement of energy performance. International relevance is particularly important for companies with a global presence or trading interests, providing them with access to supporting ISO standards and a growing body of certified companies representing the collective knowledge of communities of practice. This paper examines the business value of SEP, a voluntary program that builds on ISO 50001, inviting industry to demonstrate an even greater commitment through third-party verification of energy performance improvement to a specified level of achievement. Information from 28 facilities that have already achieved SEP certification will illustrate key findings concerning both the value and the challenges from SEP/ISO 50001 implementation. These include the facilities’ experience with implementation, internal and external value of third-party verification of energy performance improvement; attractive payback periods and the importance of SEP tools and guidance. US DOE is working to bring the program to scale, including the Enterprise-Wide Accelerator (SEP for multiple facilities in a company), the Ratepayer-Funded Program Accelerator (supporting tools for utilities and program administrators to include SEP in their program offerings), and expansion of the program to other sectors and industry supply chains.

  19. Energy performance assessment in urban planning competitions

    International Nuclear Information System (INIS)

    Eicker, Ursula; Monien, Dirk; Duminil, Éric; Nouvel, Romain

    2015-01-01

    Highlights: • Quantification of energy efficiency in urban planning. • Analysis based on 3D (city) model. • Impact evaluation of urban form on energy demand, supply and building costs. • Primary energy balance with and without inclusion of shadowing effects. - Abstract: Many cities today are committed to increase the energy efficiency of buildings and the fraction of renewables especially in new urban developments. However, quantitative data on building energy performance as a function of urban density, building compactness and orientation, building use and supply options are rarely available during the design of new cities or early scenario analysis for existing city quarters, making it difficult for cities to effectively evaluate which concepts work today and in the future. The paper proposes a methodology to assess the energy demand and supply options as a function of the availability of geometry, building standard and use data. An automated procedure was implemented to identify each building’s geometry and volume and transfer the information to a simulation tool, which then calculates heating demand and solar energy generation on roofs and facades. The simulation includes shading calculations for each segment of the façades and roofs and thus allows a very detailed quantification of the building energy demand. By applying the methodology to a case study city quarter designed in an urban competition in Munich, it could be shown how the urban design influences the energy demand of the quarter and which fractions of renewable energy can be integrated into the roofs. While the building insulation standard and use are the is most important criteria for building energy efficiency (with an impact of more than a factor 2), the exact geometrical form, compactness and urban shading effects influences the energy demand by 10–20%. On the other hand, the detailed roof geometry and orientation influences the possible solar coverage of electricity or thermal

  20. Mandatory Class 1 Federal Areas Web Service

    Data.gov (United States)

    U.S. Environmental Protection Agency — This web service contains the following layers: Mandatory Class 1 Federal Area polygons and Mandatory Class 1 Federal Area labels in the United States. The polygon...

  1. Performance of deep geothermal energy systems

    Science.gov (United States)

    Manikonda, Nikhil

    Geothermal energy is an important source of clean and renewable energy. This project deals with the study of deep geothermal power plants for the generation of electricity. The design involves the extraction of heat from the Earth and its conversion into electricity. This is performed by allowing fluid deep into the Earth where it gets heated due to the surrounding rock. The fluid gets vaporized and returns to the surface in a heat pipe. Finally, the energy of the fluid is converted into electricity using turbine or organic rankine cycle (ORC). The main feature of the system is the employment of side channels to increase the amount of thermal energy extracted. A finite difference computer model is developed to solve the heat transport equation. The numerical model was employed to evaluate the performance of the design. The major goal was to optimize the output power as a function of parameters such as thermal diffusivity of the rock, depth of the main well, number and length of lateral channels. The sustainable lifetime of the system for a target output power of 2 MW has been calculated for deep geothermal systems with drilling depths of 8000 and 10000 meters, and a financial analysis has been performed to evaluate the economic feasibility of the system for a practical range of geothermal parameters. Results show promising an outlook for deep geothermal systems for practical applications.

  2. The energy performance contract - key towards energy efficiency in Europe?

    Directory of Open Access Journals (Sweden)

    Murafa Corina

    2017-07-01

    Full Text Available The paper focuses on the Energy Performance Contract (EPC as a business model for energy efficiency. More precisely, it examines, using two case studies, enablers and disablers – from an economic, legal and institutional/managerial perspective – for advancing this arrangement across the EU. The EU has set a 20% energy savings target by 2020 (roughly equivalent to turning off 400 power stations, with an even more ambitious target of 27% by 2030. To reach these ambitious targets, the investments needed are approximately EUR 100 bn/year across the EU (according to the European Commission. Energy efficiency is not, as fervent proponents often claim, the low hanging fruit in terms of investment efforts. Like any other sub-sector, such as transmission and distribution, it demands innovative financing instruments to ensure adequate scale-up. In the paper, I use two comparative case studies to identify and classify the disablers and enablers of Energy Performance Contracting/Energy Services Companies (ESCOs development: the European frontrunner, namely Germany, and a laggard, namely Romania. As research methodology, I use literature review, comparisons between similar government policy planning and evaluation documents, and stakeholder interviews. While academic literature on the topic (Seefeldt, 2003; Wilhelm, 2015 is developed for Germany, for Romania a critical reflection on EPC promotion policy is to be found only in industry documents (e.g.: ARPEE, 2013; Tractebel, 2015. The German success demonstrates that, contrary to the belief of Romanian stakeholders, it is not the lack of a standardized contract model that prevents EPC development, but lack of genuine commitment, drive and leadership of public officials in promoting this financing instrument. A solid communication between public authorities and private beneficiaries, and public administration capacity for impact assessment and evidence-based policy planning are two other significant

  3. An aggregated energy security performance indicator

    International Nuclear Information System (INIS)

    Martchamadol, Jutamanee; Kumar, S.

    2013-01-01

    Highlights: ► AESPI shows a country’s (or province’s) energy security status. ► AESPI considers social, economic and environmental aspects using 25 indicators. ► AESPI shows the impact of the trend of energy policies/measures. ► AESPI could be a tool for monitoring and evaluating the impact of energy policies. -- Abstract: An “Aggregated Energy Security Performance Indicator (AESPI)” has been developed by considering 25 individual indicators representing social, economy and environmental dimensions. The principle used, data required and the methodology for the development of AESPI have been detailed. AESPI requires time series data for its development and its value ranges from 0 to 10. The characteristics of AESPI have been compared with the existing indicators in terms of methodology, data requirements, analysis possible and the applications. The advantages of AESPI is that it not only assists in knowing the past energy security status of a country, but also helps in assessing the future status considering the energy policies and plans of the country, thus enabling the monitoring of the impacts of the policies.

  4. Empirical Study on Annual Energy-Saving Performance of Energy Performance Contracting in China

    Directory of Open Access Journals (Sweden)

    Hongquan Ruan

    2018-05-01

    Full Text Available A lack of trust in Energy Service Company (ESCo is the most critical factor affecting the development of Energy Performance Contracting (EPC in China, compared with other constraints. One cannot easily estimate the energy-saving performance of an EPC project. Under that condition, lack of trust may cause the Energy-Consuming Unit (ECU to suspect the energy-saving performance promised by the ESCo, thus leaving potentially profitable projects without necessary funding. Currently, specific studies taking an across-projects viewpoint on annual energy-saving performance of EPC projects in multiple subsectors, objectively and quantitatively, are lacking. This paper studies the regression relationships of annual energy-saving quantity in terms of revamping cost and the regression relationships of annual cost saving in terms of revamping cost. The regression results show that there are statistically significant correlations in the above relationships in the nine subsectors investigated. This is significant for ESCos and ECUs, because knowledge on energy-saving performance could contribute to EPC investment decisions and trust relationships between ESCos and ECUs. Then, a multiple linear regression model of revamping cost is set up to analyze its influencing factors. The model indicates that the subsector the sample belongs to, financing, registered capital of the ESCo, and contract period have significant effects on revamping cost. Thus, policy implications regarding innovation of EE promotion technology, clarifying ESCos’ exit mechanism, innovation of financing mechanism, and improving the market credit environment for promoting investment in EPC projects, are provided.

  5. Performance Limits of Communication with Energy Harvesting

    KAUST Repository

    Znaidi, Mohamed Ridha

    2016-04-01

    In energy harvesting communications, the transmitters have to adapt transmission to the availability of energy harvested during communication. The performance of the transmission depends on the channel conditions which vary randomly due to mobility and environmental changes. During this work, we consider the problem of power allocation taking into account the energy arrivals over time and the quality of channel state information (CSI) available at the transmitter, in order to maximize the throughput. Differently from previous work, the CSI at the transmitter is not perfect and may include estimation errors. We solve this problem with respect to the energy harvesting constraints. Assuming a perfect knowledge of the CSI at the receiver, we determine the optimal power policy for different models of the energy arrival process (offline and online model). Indeed, we obtain the power allocation scheme when the transmitter has either perfect CSI or no CSI. We also investigate of utmost interest the case of fading channels with imperfect CSI. Moreover, a study of the asymptotic behavior of the communication system is proposed. Specifically, we analyze of the average throughput in a system where the average recharge rate goes asymptotically to zero and when it is very high.

  6. New perspectives on community-acquired pneumonia in 388 406 patients. Results from a nationwide mandatory performance measurement programme in healthcare quality.

    Science.gov (United States)

    Ewig, S; Birkner, N; Strauss, R; Schaefer, E; Pauletzki, J; Bischoff, H; Schraeder, P; Welte, T; Hoeffken, G

    2009-12-01

    The database of the German programme for quality in healthcare including data of every hospitalised patient with community-acquired pneumonia (CAP) during a 2-year period (n = 388 406 patients in 2005 and 2006) was analysed. End points of the analysis were: (1) incidence; (2) outcome; (3) performance of the CRB-65 (C, mental confusion; R, respiratory rate >or=30/min; B, systolic blood pressure or=65 years) score in predicting death; and (4) lack of ventilatory support as a possible indicator of treatment restrictions. The CRB-65 score was calculated, resulting in three risk classes (RCs). The incidence of hospitalised CAP was 2.75 and 2.96 per 1000 inhabitants/year in 2005 and 2006, respectively, higher for males (3.21 vs 2.52), and strongly age related, with an incidence of 7.65 per 1000 inhabitants/year in patients aged >or=60 years over 2 years. Mortality (13.72% and 14.44%) was higher than reported in previous studies. The CRB-65 RCs accurately predicted death in a three-class pattern (mortality 2.40% in CRB-65 RC 1, 13.43% in CRB-65 RC 2 and 34.39% in CRB-65 RC 3). The first days after admission were consistently associated with the highest risk of death throughout all risk classes. Only a minority of patients who died had received mechanical ventilation during hospitalisation (15.74%). Hospitalised CAP basically is a condition of the elderly associated with a higher mortality than previously reported. It bears a considerable risk of early mortality, even in low risk patients. CRB-65 is a simple and powerful tool for the assessment of CAP severity. Hospitalised CAP is a frequent terminal event in chronic debilitated patients, and a limitation of treatment escalation is frequently applied.

  7. Energy Efficient Graphene Based High Performance Capacitors.

    Science.gov (United States)

    Bae, Joonwon; Kwon, Oh Seok; Lee, Chang-Soo

    2017-07-10

    Graphene (GRP) is an interesting class of nano-structured electronic materials for various cutting-edge applications. To date, extensive research activities have been performed on the investigation of diverse properties of GRP. The incorporation of this elegant material can be very lucrative in terms of practical applications in energy storage/conversion systems. Among various those systems, high performance electrochemical capacitors (ECs) have become popular due to the recent need for energy efficient and portable devices. Therefore, in this article, the application of GRP for capacitors is described succinctly. In particular, a concise summary on the previous research activities regarding GRP based capacitors is also covered extensively. It was revealed that a lot of secondary materials such as polymers and metal oxides have been introduced to improve the performance. Also, diverse devices have been combined with capacitors for better use. More importantly, recent patents related to the preparation and application of GRP based capacitors are also introduced briefly. This article can provide essential information for future study. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  8. Procedure for Measuring and Reporting Commercial Building Energy Performance

    Energy Technology Data Exchange (ETDEWEB)

    Barley, D.; Deru, M.; Pless, S.; Torcellini, P.

    2005-10-01

    This procedure is intended to provide a standard method for measuring and characterizing the energy performance of commercial buildings. The procedure determines the energy consumption, electrical energy demand, and on-site energy production in existing commercial buildings of all types. The performance metrics determined here may be compared against benchmarks to evaluate performance and verify that performance targets have been achieved.

  9. 10 CFR 433.4 - Energy efficiency performance standard.

    Science.gov (United States)

    2010-01-01

    ... 10 Energy 3 2010-01-01 2010-01-01 false Energy efficiency performance standard. 433.4 Section 433.4 Energy DEPARTMENT OF ENERGY ENERGY CONSERVATION ENERGY EFFICIENCY STANDARDS FOR THE DESIGN AND... consumption level at or better than the maximum level of energy efficiency that is life-cycle cost-effective...

  10. Comparisons of mandatory and discretionary lane changing behavior on freeways

    Directory of Open Access Journals (Sweden)

    Matthew Vechione

    2018-06-01

    Full Text Available This research performs comparative analyses on drivers’ behavior during mandatory and discretionary lane changes. We do this by examining the statistical properties of four lane changing decision variables that describe the gaps between the subject vehicle and the surrounding vehicles. Mandatory and discretionary lane changes in NGSIM’s I-80 Freeway and U.S. Highway 101 data collection sites were identified. First, for each variable at the same site, descriptive statistics for the two types of lane changes were compared, and hypothesis tests on the difference between two means were conducted. Then, for each decision variable at the same site, the observed cumulative distributions between the mandatory and discretionary lane changes were compared by means of the Kolmogorov–Smirnov test. This test was repeated for the fitted distributions of the same decision variable at the same site. The results show that, for the three decision variables associated with gaps in the target lane, the means and distributions between the two types of lane changes are not significantly different. The only variable found to have significant differences in means and distributions is the gap between the subject vehicle and the preceding vehicle in the original lane. This may be because this variable is not an important input in mandatory lane change decisions. This finding provides statistical justification for researchers to develop models with different inputs for mandatory and discretionary lane changes in driver assist systems, in autonomous vehicles, and in microscopic traffic simulation tools.

  11. Energy and architecture: improvement of energy performance in existing buildings

    Energy Technology Data Exchange (ETDEWEB)

    Haase, Matthias; Wycmans, Annemie; Solbraa, Anne; Grytli, Eir

    2011-07-01

    This book aims to give an overview of different aspects of retrofitting existing buildings. The target group is students of architecture and building engineering as well as building professionals. Eight out of ten buildings which we will inhabit in 2050 already exist. This means that a great potential for reducing our carbon footprint lies in the existing building stock. Students from NTNU have used the renovation of a 1950s school building at Linesoeya in Soer-Trondelag as a case to increase their awareness and knowledge about the challenges building professionals need to overcome to unite technical details and high user quality into good environmental performance. The students were invited by the building owners and initiators of LIPA Eco Project to contribute to its development: By retrofitting an existing building to passive house standards and combining this with energy generated on site, LIPA Eco Project aims to provide a hands-on example with regard to energy efficiency, architectural design and craftsmanship for a low carbon society. The overall goal for this project is to raise awareness regarding resource efficiency measures in architecture and particularly in existing building mass.(au)

  12. Reminder: Mandatory Computer Security Course

    CERN Multimedia

    IT Department

    2011-01-01

    Just like any other organization, CERN is permanently under attack – even right now. Consequently it's important to be vigilant about security risks, protecting CERN's reputation - and your work. The availability, integrity and confidentiality of CERN's computing services and the unhindered operation of its accelerators and experiments come down to the combined efforts of the CERN Security Team and you. In order to remain par with the attack trends, the Security Team regularly reminds CERN users about the computer security risks, and about the rules for using CERN’s computing facilities. Therefore, a new dedicated basic computer security course has been designed informing you about the “Do’s” and “Dont’s” when using CERN's computing facilities. This course is mandatory for all person owning a CERN computer account and must be followed once every three years. Users who have never done the course, or whose course needs to be renewe...

  13. New Mandatory Computer Security Course

    CERN Multimedia

    CERN Bulletin

    2010-01-01

    Just like any other organization, CERN is permanently under attack - even right now. Consequently it's important to be vigilant about security risks, protecting CERN's reputation - and your work. The availability, integrity and confidentiality of CERN's computing services and the unhindered operation of its accelerators and experiments come down to the combined efforts of the CERN Security Team and you. In order to remain par with the attack trends, the Security Team regularly reminds CERN users about the computer security risks, and about the rules for using CERN’s computing facilities. Since 2007, newcomers have to follow a dedicated basic computer security course informing them about the “Do’s” and “Dont’s” when using CERNs computing facilities. This course has recently been redesigned. It is now mandatory for all CERN members (users and staff) owning a CERN computer account and must be followed once every three years. Members who...

  14. Civil defense should be mandatory

    International Nuclear Information System (INIS)

    Kearney, C.H.

    1985-01-01

    In this paper, the author exposes myths about the effects of nuclear weapons so that the U.S. can begin the necessary task of a mandatory civil defense program. An all-out nuclear war between Russia and the United States would be the worst catastrophe in history, a tragedy so huge it is difficult to comprehend. Even so, it would be far from the end of human life on earth. The dangers from nuclear weapons have been distorted and exaggerated for varied reasons. These exaggerations have become demoralizing myths, believed by millions of Americans. The author has found that many people see no sense in talking about details of survival skills. Only after they have begun to question the truth of these myths do they become interested, under normal peacetime conditions, in acquiring nuclear war survival skills. The author examines the most harmful of the myths about nuclear war dangers, along with some of the grim facts

  15. Comparison of energy performance requirements levels

    DEFF Research Database (Denmark)

    Spiekman, Marleen; Thomsen, Kirsten Engelund; Rose, Jørgen

    This summary report provides a synthesis of the work within the EU SAVE project ASIEPI on developing a method to compare the energy performance (EP) requirement levels among the countries of Europe. Comparing EP requirement levels constitutes a major challenge. From the comparison of for instance...... the present Dutch requirement level (EPC) of 0,8 with the present Flemish level of E80, it can easily be seen that direct comparison is not possible. The conclusions and recommendations of the study are presented in part A. These constitute the most important result of the project. Part B gives an overview...... of all other project material related to that topic, which allows to easily identify the most pertinent information. Part C lists the project partners and sponsors....

  16. Job-specific mandatory medical examinations for the police force

    NARCIS (Netherlands)

    Boschman, J. S.; Hulshof, C. T. J.; Frings-Dresen, M. H. W.; Sluiter, J. K.

    2017-01-01

    Background Mandatory medical examinations (MMEs) of workers should be based on the health and safety requirements that are needed for effectively performing the relevant work. For police personnel in the Netherlands, no job-specific MME exists that takes the specific tasks and duties into account.

  17. Mandatory IFRS Reporting and Stock Price Informativeness

    NARCIS (Netherlands)

    Beuselinck, C.A.C.; Joos, P.P.M.; Khurana, I.K.; van der Meulen, S.

    2010-01-01

    In this paper, we examine whether mandatory adoption of IFRS influences the flow of firm-specific information and contributes to stock price informativeness as measured by stock return synchronicity. Using a constant sample of 1,904 mandatory IFRS adopters in 14 EU countries for the period

  18. 78 FR 20097 - Energy Savings Performance Contracts

    Science.gov (United States)

    2013-04-03

    ... procedures, scope definition, Measurement and Verification (M&V), financing procurement, and definition of... government. More than $2.71 billion has been invested in Federal energy efficiency and renewable energy... more than $7.18 billion of cumulative energy cost savings for the Federal Government. While FEMP has...

  19. Energy performance of the low-energy house in Greenland

    DEFF Research Database (Denmark)

    Kragh, Jesper; Svendsen, Svend

    2005-01-01

    by ventilation heat recovery (90% efficiency) specially designed for arctic conditions, by using thicker insulation in walls (300 mm) and roof/floor (350 mm), and by using solar hot water heating (3250 kWh/year). The building is intended to enhance sustainability in the building sector in Greenland....... energy gain, efficient ventilation system with heat recovery and solar heating. In this paper the results of a calculation of the energy consumption of low-energy house is presented. The calculation was done using the program BSim2002 [1] and a new weather test reference year based on climatic data......The object of the low-energy house in Sisimiut in Greenland was to build a house with an energy consumption less than 80 kWh/m² corresponding to half the energy frame of the coming building code. Therefore the focus in this project has been on large insulation thicknesses, windows with high net...

  20. Performance profiles of major energy producers 1996

    International Nuclear Information System (INIS)

    1998-01-01

    This publication examines developments in the operations of the major US e energy-producing companies on a corporate level, by major line of business, by major function within each line of business, and by geographic area. In 1996, 24 companies filed Form EIA-28. The analysis and data presented in this report represents the operations of the Financial Reporting System companies in the context of their worldwide operations and in the context of the major energy markets which they serve. Both energy and nonenergy developments of these companies are analyzed. Although the focus is on developments in 1996, important trends prior to that time are also featured. Sections address energy markets in 1996; key financial developments; oil and gas exploration, development, and production; downstream petroleum in 1996; coal and alternative energy; and foreign direct investment in US energy. 30 figs., 104 tabs

  1. Performance profiles of major energy producers 1996

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-01-01

    This publication examines developments in the operations of the major US e energy-producing companies on a corporate level, by major line of business, by major function within each line of business, and by geographic area. In 1996, 24 companies filed Form EIA-28. The analysis and data presented in this report represents the operations of the Financial Reporting System companies in the context of their worldwide operations and in the context of the major energy markets which they serve. Both energy and nonenergy developments of these companies are analyzed. Although the focus is on developments in 1996, important trends prior to that time are also featured. Sections address energy markets in 1996; key financial developments; oil and gas exploration, development, and production; downstream petroleum in 1996; coal and alternative energy; and foreign direct investment in US energy. 30 figs., 104 tabs.

  2. Solar energy photovoltaic technology: proficiency and performance

    International Nuclear Information System (INIS)

    2006-01-01

    Total is committed to making the best possible of the planet's fossil fuel reserves while fostering the emergence of other solutions, notably by developing effective alternatives. Total involves in photovoltaics when it founded in 1983 Total Energies, renamed Tenesol in 2005, a world leader in the design and installation of photovoltaic solar power systems. This document presents Total's activities in the domain: the global challenge of energy sources and the environment, the energy collecting by photovoltaic electricity, the silicon technology for cell production, solar panels and systems to distribute energy, research and development to secure the future. (A.L.B.)

  3. Towards measurement and verification of energy performance under the framework of the European directive for energy performance of buildings

    International Nuclear Information System (INIS)

    Burman, Esfand; Mumovic, Dejan; Kimpian, Judit

    2014-01-01

    Directive 2002/91/EC of the European Parliament and Council on the Energy Performance of Buildings has led to major developments in energy policies followed by the EU Member States. The national energy performance targets for the built environment are mostly rooted in the Building Regulations that are shaped by this Directive. Article 3 of this Directive requires a methodology to calculate energy performance of buildings under standardised operating conditions. Overwhelming evidence suggests that actual energy performance is often significantly higher than this standardised and theoretical performance. The risk is national energy saving targets may not be achieved in practice. The UK evidence for the education and office sectors is presented in this paper. A measurement and verification plan is proposed to compare actual energy performance of a building with its theoretical performance using calibrated thermal modelling. Consequently, the intended vs. actual energy performance can be established under identical operating conditions. This can help identify the shortcomings of construction process and building procurement. Once energy performance gap is determined with reasonable accuracy and root causes identified, effective measures could be adopted to remedy or offset this gap. - Highlights: • Building energy performance gap is a negative externality that must be addressed. • A method is proposed to link actual performance to building compliance calculation. • Energy performance gap is divided into procurement and operational gaps. • This framework enables policy makers to measure and address procurement gap. • Building fine-tuning by construction teams could also narrow operational gap

  4. Energy performance contracting - energy saving potential of selected energy conservation measures (ECM)

    Energy Technology Data Exchange (ETDEWEB)

    Johansson, M. (Dansk Energi Analyse A/S, Frederiksberg (Denmark)); Langkilde, G.; Olesen, Bjarne W. (Technical Univ. of Denmark, ICIEE, Kgs. Lyngby (Denmark)); Moerck, O. (Cenergia Energy Consultants, Herlev (Denmark)); Sundman, O. (DONG Energy, Copenhagen (Denmark)); Engelund Thomsen, K. (Aalborg Univ., SBi, Hoersholm (Denmark))

    2008-09-15

    This report has been developed under the research project 'Etablering af grundlag for energitjenester i Danmark' (project number: ENS-33031-0185) under the Danish research programme - EFP. The objective of this project has been to contribute to the utilisation of the large potential for energy conservations in the building sector within the public, industry and service sectors through the development of a better basis for decision making for both the Energy Service Companies (ESCOes) and the building owners. The EU directive on Energy Service Contracting points at the buildings as the area where the biggest potential market for energy services and energy efficiency improvements are. The EFP-project has two parts: (1) A Danish part and (2) participation in the international cooperation project 'Holistic Assesment Tool-Kit on Energy Efficient Retrofit Measures for Government Buildings (EnERGo)', Annex 46 under the IEA R and D program 'Energy Conservation In Buildings And Community Systems' (ECBCS). This report describes the Danish contributions to the IEA projects subtask B, which has a primary objective to develop a database of energy conservation measures (ECM) with descriptions and performance characteristics of these. (au)

  5. Energy performance contracting - energy saving potential of selected energy conservation measures (ECM)

    Energy Technology Data Exchange (ETDEWEB)

    Johansson, M [Dansk Energi Analyse A/S, Frederiksberg (Denmark); Langkilde, G; Olesen, Bjarne W [Technical Univ. of Denmark, ICIEE, Kgs. Lyngby (Denmark); Moerck, O [Cenergia Energy Consultants, Herlev (Denmark); Sundman, O [DONG Energy, Copenhagen (Denmark); Engelund Thomsen, K [Aalborg Univ., SBi, Hoersholm (Denmark)

    2008-09-15

    This report has been developed under the research project 'Etablering af grundlag for energitjenester i Danmark' (project number: ENS-33031-0185) under the Danish research programme - EFP. The objective of this project has been to contribute to the utilisation of the large potential for energy conservations in the building sector within the public, industry and service sectors through the development of a better basis for decision making for both the Energy Service Companies (ESCOes) and the building owners. The EU directive on Energy Service Contracting points at the buildings as the area where the biggest potential market for energy services and energy efficiency improvements are. The EFP-project has two parts: (1) A Danish part and (2) participation in the international cooperation project 'Holistic Assesment Tool-Kit on Energy Efficient Retrofit Measures for Government Buildings (EnERGo)', Annex 46 under the IEA R and D program 'Energy Conservation In Buildings And Community Systems' (ECBCS). This report describes the Danish contributions to the IEA projects subtask B, which has a primary objective to develop a database of energy conservation measures (ECM) with descriptions and performance characteristics of these. (au)

  6. Mandatory IFRS adoption and executive compensation: Evidence from China

    Directory of Open Access Journals (Sweden)

    Qingchuan Hou

    2014-03-01

    Full Text Available This study investigates how the mandatory adoption of International Financial Reporting Standards (IFRS affects the contractual benefits of using accounting information to determine executive compensation in China. After controlling for firm and corporate governance characteristics, we find strong evidence supporting the positive role of mandatory IFRS adoption on the accounting-based performance sensitivity of executive compensation. Subsample analysis suggests that improvements in accounting-based performance sensitivity after IFRS adoption differ across regions with various levels of institutional quality and across firms that are affected to a different extent by the adoption. Additional analysis supports the argument that the positive effects of IFRS adoption on the use of accounting performance in executive compensation are driven by the reduction in accounting conservatism associated with IFRS adoption.

  7. Estimate of Cost-Effective Potential for Minimum Efficiency Performance Standards in 13 Major World Economies Energy Savings, Environmental and Financial Impacts

    Energy Technology Data Exchange (ETDEWEB)

    Letschert, Virginie E. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Bojda, Nicholas [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Ke, Jing [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); McNeil, Michael A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-07-01

    This study analyzes the financial impacts on consumers of minimum efficiency performance standards (MEPS) for appliances that could be implemented in 13 major economies around the world. We use the Bottom-Up Energy Analysis System (BUENAS), developed at Lawrence Berkeley National Laboratory (LBNL), to analyze various appliance efficiency target levels to estimate the net present value (NPV) of policies designed to provide maximum energy savings while not penalizing consumers financially. These policies constitute what we call the “cost-effective potential” (CEP) scenario. The CEP scenario is designed to answer the question: How high can we raise the efficiency bar in mandatory programs while still saving consumers money?

  8. Models for the energy performance of low-energy houses

    DEFF Research Database (Denmark)

    Andersen, Philip Hvidthøft Delff

    of buildings, the first topic analyzed is the variation of presence of occupants. As buildings get more energy-effcient, internal loads and user-behavior increasingly influence the energy consumption. Most simulation tools use deterministic occupancy profiles to simulate internal loads. However, such occupancy......The aim of this thesis is data-driven modeling of heat dynamics of buildings. Traditionally, thermal modeling of buildings is done using simulation tools which take information about the construction, weather data, occupancy etc. as inputs and generate deterministic energy profiles of the buildings....... The approach to modeling occupants’ presence provides a flexible method where no assumptions in the application. The rest of the thesis deals with statistical modeling of heat dynamics of buildings. First, discrete-time models are applied. Discrete-time models are computationally relatively simple and provide...

  9. Mandatory Vaccinations: Precedent and Current Laws

    National Research Council Canada - National Science Library

    Welborn, Angie A

    2005-01-01

    This report discusses the history legal precedent for mandatory vaccination laws and provides a brief overview of state laws that require certain individuals or populations to be vaccinated against...

  10. Computational Fluid Dynamics and Building Energy Performance Simulation

    DEFF Research Database (Denmark)

    Nielsen, Peter V.; Tryggvason, Tryggvi

    An interconnection between a building energy performance simulation program and a Computational Fluid Dynamics program (CFD) for room air distribution will be introduced for improvement of the predictions of both the energy consumption and the indoor environment. The building energy performance...

  11. Impacts of FDI Renewable Energy Technology Spillover on China’s Energy Industry Performance

    Directory of Open Access Journals (Sweden)

    Weiwei Liu

    2016-08-01

    Full Text Available Environmental friendly renewable energy plays an indispensable role in energy industry development. Foreign direct investment (FDI in advanced renewable energy technology spillover is promising to improve technological capability and promote China’s energy industry performance growth. In this paper, the impacts of FDI renewable energy technology spillover on China’s energy industry performance are analyzed based on theoretical and empirical studies. Firstly, three hypotheses are proposed to illustrate the relationships between FDI renewable energy technology spillover and three energy industry performances including economic, environmental, and innovative performances. To verify the hypotheses, techniques including factor analysis and data envelopment analysis (DEA are employed to quantify the FDI renewable energy technology spillover and the energy industry performance of China, respectively. Furthermore, a panel data regression model is proposed to measure the impacts of FDI renewable energy technology spillover on China’s energy industry performance. Finally, energy industries of 30 different provinces in China based on the yearbook data from 2005 to 2011 are comparatively analyzed for evaluating the impacts through the empirical research. The results demonstrate that FDI renewable energy technology spillover has positive impacts on China’s energy industry performance. It can also be found that the technology spillover effects are more obvious in economic and technological developed regions. Finally, four suggestions are provided to enhance energy industry performance and promote renewable energy technology spillover in China.

  12. Comparability Effects of Mandatory IFRS Adoption

    OpenAIRE

    Stefano Cascino; Joachim Gassen

    2012-01-01

    The mandatory adoption of IFRS by many countries worldwide fuels the expectation that financial accounting information might become more comparable across countries. This expectation is opposed to an alternative view that stresses the importance of incentives in shaping accounting information. We provide early evidence on this debate by investigating the effects of mandatory IFRS adoption on the comparability of financial accounting information around the world. Using two comparability proxie...

  13. Mandatory IFRS adoption and accounting comparability

    OpenAIRE

    Cascino, Stefano; Gassen, Joachim

    2010-01-01

    The adoption of IFRS by many countries worldwide fuels the expectation that financial accounting might become more comparable across countries. This expectation is opposed to an alternative view that stresses the importance of incentives in shaping accounting information. We provide early evidence on this debate by investigating the effects of mandatory IFRS adoption on the comparability of financial accounting information around the world. Our results suggest that while mandatory adoption of...

  14. Energy Design Guidelines for High Performance Schools: Tropical Island Climates

    Energy Technology Data Exchange (ETDEWEB)

    None

    2004-11-01

    Design guidelines outline high performance principles for the new or retrofit design of K-12 schools in tropical island climates. By incorporating energy improvements into construction or renovation plans, schools can reduce energy consumption and costs.

  15. Performance profiles of major energy producers 1979

    International Nuclear Information System (INIS)

    1981-07-01

    The purpose of this report is to examine year-to-year developments in the operations of 26 major US energy companies on a corporate level and also by major line of energy business and by major functions within each line of business. The period covered is 1977 to 1979. Comparisons of income and investment flow are featured and related to functionally allocated net investment in place. The presentation seeks to identify similarities and dissimilarities in results across lines-of-business activity or by firm size

  16. Energy Design Guidelines for High Performance Schools: Tropical Island Climates

    Energy Technology Data Exchange (ETDEWEB)

    2004-11-01

    The Energy Design Guidelines for High Performance Schools--Tropical Island Climates provides school boards, administrators, and design staff with guidance to help them make informed decisions about energy and environmental issues important to school systems and communities. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school in tropical island climates. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs.

  17. Mandatory Disclosure and Operational Risk: Evidence from Hedge Fund Registration

    OpenAIRE

    Stephen Brown; William Goetzmann; Bing Liang; Christopher Schwarz

    2006-01-01

    Mandatory disclosure is a regulatory tool intended to allow market participants to assess operational risk. We examine the value of disclosure through the controversial SEC requirement, since overturned, which required major hedge funds to register as investment advisors and file Form ADV disclosures. Leverage and ownership structures suggest that lenders and equity investors were already aware of operational risk. However, operational risk does not mediate flow-performance relationships. Inv...

  18. An urban energy performance evaluation system and its computer implementation.

    Science.gov (United States)

    Wang, Lei; Yuan, Guan; Long, Ruyin; Chen, Hong

    2017-12-15

    To improve the urban environment and effectively reflect and promote urban energy performance, an urban energy performance evaluation system was constructed, thereby strengthening urban environmental management capabilities. From the perspectives of internalization and externalization, a framework of evaluation indicators and key factors that determine urban energy performance and explore the reasons for differences in performance was proposed according to established theory and previous studies. Using the improved stochastic frontier analysis method, an urban energy performance evaluation and factor analysis model was built that brings performance evaluation and factor analysis into the same stage for study. According to data obtained for the Chinese provincial capitals from 2004 to 2013, the coefficients of the evaluation indicators and key factors were calculated by the urban energy performance evaluation and factor analysis model. These coefficients were then used to compile the program file. The urban energy performance evaluation system developed in this study was designed in three parts: a database, a distributed component server, and a human-machine interface. Its functions were designed as login, addition, edit, input, calculation, analysis, comparison, inquiry, and export. On the basis of these contents, an urban energy performance evaluation system was developed using Microsoft Visual Studio .NET 2015. The system can effectively reflect the status of and any changes in urban energy performance. Beijing was considered as an example to conduct an empirical study, which further verified the applicability and convenience of this evaluation system. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. Practical performances of MPC for wave energy converters

    DEFF Research Database (Denmark)

    Ferri, Francesco; Tetu, Amelie; Hals, J.

    2016-01-01

    Maximising the efficiency of Wave Energy Converter (WEC) is one of the important tasks toward the exploitation of the wave energy resource. Along with a proper design of the device, an important way to achieve better energy performances is to improve the wave-body interaction by applying an appro...

  20. Optimal energy management of urban rail systems: Key performance indicators

    International Nuclear Information System (INIS)

    González-Gil, A.; Palacin, R.; Batty, P.

    2015-01-01

    Highlights: • An overall picture of urban rail energy use is provided. • Performance indicators are developed for urban rail system energy optimisation. • A multi-level methodology for assessing energy efficiency measures is presented. - Abstract: Urban rail systems are facing increasing pressure to minimise their energy consumption and thusly reduce their operational costs and environmental impact. However, given the complexity of such systems, this can only be effectively achieved through a holistic approach which considers the numerous interdependences between subsystems (i.e. vehicles, operations and infrastructure). Such an approach requires a comprehensive set of energy consumption-related Key Performance Indicators (KEPIs) that enable: a multilevel analysis of the actual energy performance of the system; an assessment of potential energy saving strategies; and the monitoring of the results of implemented measures. This paper proposes an original, complete list of KEPIs developed through a scientific approach validated by different stakeholders. It consists of a hierarchical list of 22 indicators divided into two levels: 10 key performance indicators, to ascertain the performance of the whole system and complete subsystems; and 12 performance indicators, to evaluate the performance of single units within subsystems, for example, a single rail vehicle or station. Additionally, the paper gives a brief insight into urban rail energy usage by providing an adequate context in which to understand the proposed KEPIs, together with a methodology describing their application when optimising the energy consumption of urban rail systems

  1. 75 FR 59261 - Mandatory Reliability Standards for the Bulk Power System; Supplemental Notice of Technical...

    Science.gov (United States)

    2010-09-27

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket Nos. RM06-16-010; RM06-16-011] Mandatory Reliability Standards for the Bulk Power System; Supplemental Notice of Technical Conference September 17, 2010. On August 19, 2010 the Federal Energy Regulatory Commission announced that a Technical...

  2. 75 FR 57764 - Mandatory Reliability Standards for the Bulk Power System; Supplemental Notice of Technical...

    Science.gov (United States)

    2010-09-22

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket Nos. RM06-16-010; RM06-16-011] Mandatory Reliability Standards for the Bulk Power System; Supplemental Notice of Technical Conference September 14, 2010. On August 19, 2010 the Federal Energy Regulatory Commission announced that a Technical...

  3. 75 FR 61478 - Mandatory Reliability Standards for the Bulk Power System; Notice Allowing Post-Technical...

    Science.gov (United States)

    2010-10-05

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket Nos. RM06-16-010; RM06-16-011] Mandatory Reliability Standards for the Bulk Power System; Notice Allowing Post-Technical Conference Comments September 24, 2010. On September 23, 2010, the Federal Energy Regulatory Commission conducted a...

  4. [Quality measurement using administrative data in mandatory quality assurance].

    Science.gov (United States)

    Heller, Günther; Szecsenyi, Joachim; Willms, Gerald; Broge, Björn

    2014-01-01

    For several years, the use of administrative data in mandatory quality measurement has been requested by several stakeholders in Germany. Main advantages of using administrative data include the reduction of documentary expenditures and the possibility to perform longitudinal quality analyses across different healthcare units. After a short introduction, a brief overview of the current use of administrative data for mandatory quality assurance as well as current developments is given, which will then be further exemplified by decubital ulcer prophylaxis. By using administrative data coding expenditures in this clinical area could be reduced by nine million data fields. At the same time the population analysed was expanded resulting in a more than tenfold increase in potentially quality-relevant events. Finally, perspectives, further developments, possibilities as well as limits of quality measurement with administrative data are discussed. Copyright © 2014. Published by Elsevier GmbH.

  5. Dataset on the energy performance of atrium type hotel buildings.

    Science.gov (United States)

    Vujosevic, Milica; Krstic-Furundzic, Aleksandra

    2018-04-01

    The data presented in this article are related to the research article entitled "The Influence of Atrium on Energy Performance of Hotel Building" (Vujosevic and Krstic-Furundzic, 2017) [1], which describes the annual energy performance of atrium type hotel building in Belgrade climate conditions, with the objective to present the impact of the atrium on the hotel building's energy demands for space heating and cooling. This dataset is made publicly available to show energy performance of selected hotel design alternatives, in order to enable extended analyzes of these data for other researchers.

  6. Sustainable Performance in Energy Harvesting - Wireless Sensor Networks

    DEFF Research Database (Denmark)

    Fafoutis, Xenofon; Di Mauro, Alessio; Dragoni, Nicola

    2013-01-01

    In this practical demo we illustrate the concept of "sustainable performance" in Energy-Harvesting Wireless Sensor Networks (EH-WSNs). In particular, for different classes of applications and under several energy harvesting scenarios, we show how it is possible to have sustainable performance when...

  7. Mandatory IFRS Reporting and Stock Price Informativeness

    OpenAIRE

    Beuselinck, C.A.C.; Joos, P.P.M.; Khurana, I.K.; van der Meulen, S.

    2010-01-01

    In this paper, we examine whether mandatory adoption of IFRS influences the flow of firm-specific information and contributes to stock price informativeness as measured by stock return synchronicity. Using a constant sample of 1,904 mandatory IFRS adopters in 14 EU countries for the period 2003-2007, we find a V-shaped pattern in synchronicity around IFRS adoption, which is consistent with IFRS disclosures revealing new firm-specific information in the adoption period (i.e., a reduction of sy...

  8. Assessing the performance of Dutch local energy companies

    International Nuclear Information System (INIS)

    Blokhuis, Erik; Advokaat, Bart; Schaefer, Wim

    2012-01-01

    According to binding European Union agreements, the Netherlands has to cover at least 14% of its total energy use with renewable energy sources by 2020. However, the share of renewable energy in the Netherlands is small and hardly increasing. In 2010, renewable energy in the Netherlands accounted for only 3.8% of the national energy use, and has decreased with 0.4% compared to 2009. A cause of the stagnating renewable energy generation in the Netherlands is the absence of a nation-wide, clear and consistent long-term policy on the introduction of renewable energy. In order to overcome the current standstill in renewable energy adoption, several Dutch municipalities take the initiative and establish Local Energy Companies (LECs). However, to date, it is unclear which LEC type performs best. This research aims to compare the performance of existing LECs on three aspects: technology, finance, and organization. Furthermore, the performance of existing LECs is compared with theoretical reference LECs, in order to estimate efficiencies and opportunities for improvements. Finally, the influence of the recent changes in the Dutch subsidy scheme on LEC performance is examined. In order to achieve these aims, the benchmark method Data Envelopment Analysis is employed. - Highlights: ► Dutch Local Energy Companies (LECs) producing heat perform best in cost efficiency. ► Technical efficiency is highest in Dutch Local Energy Companies employing wind energy. ► Theoretical assumptions concerning LEC performance are not yet achieved in practice. ► The self supply model adds to the profitability of LECs, independent from subsidies. ► Recent changes in Dutch subsidy schemes add little to LECs’ financial performance.

  9. Environmental performance evaluation of Beijing's energy use planning

    International Nuclear Information System (INIS)

    Wang Lei; Xu Linyu; Song Huimin

    2011-01-01

    In line with rapid economic development, urban energy consumption is increasing rapidly, resulting in environmental problems. After considering several methods to evaluate the environmental performance of energy use, including: energy ecological footprint, input-output analysis, emergy-exergy analysis, and multi-criteria decision-making, an environmental performance evaluation model is proposed, which combines the analytical hierarchy process, fuzzy extent analysis, and membership degree analysis. In the model, 18 sub-indicators of environmental performance from energy use planning are classified into four categories: structure of energy use and industry, technology and efficiency of energy use, environmental impacts caused by energy use, and the socio-economic benefits of energy use. Membership degree analysis is applied to each indicator. Three energy use scenarios which are, respectively, environment-friendly, technology-led, and economic policy-led are evaluated. The results show that the technology-led energy use planning is best. The sustainable energy use policies are proposed from three aspects, including optimizing the energy use and industrial structure, encouraging development of energy-saving and air pollution control technologies, and enhancing legislation on energy use management. The policies are helpful to optimize the trade-offs between economic growth and environmental protection in Beijing. - Highlights: → Our paper establishes a system of indicators according to the structure of urban energy use planning. → We have created a comprehensive environmental performance evaluation model in the research. → The model and results can serve as an important basis for decision-making to guide local government.

  10. Thermodynamic performance assessment of wind energy systems: An application

    International Nuclear Information System (INIS)

    Redha, Adel Mohammed; Dincer, Ibrahim; Gadalla, Mohamed

    2011-01-01

    In this paper, the performance of wind energy system is assessed thermodynamically, from resource and technology perspectives. The thermodynamic characteristics of wind through energy and exergy analyses are considered and both energetic and exergetic efficiencies are studied. Wind speed is affected by air temperature and pressure and has a subsequent effect on wind turbine performance based on wind reference temperature and Bernoulli's equation. VESTAS V52 wind turbine is selected for (Sharjah/UAE). Energy and exergy efficiency equations for wind energy systems are further developed for practical applications. The results show that there are noticeable differences between energy and exergy efficiencies and that exergetic efficiency reflects the right/actual performance. Finally, exergy analysis has been proven to be the right tool used in design, simulation, and performance evaluation of all renewable energy systems. -- Highlights: → In this research the performance of wind energy system is assessed thermodynamically, from resource and technology perspectives. → Energy and exergy equations for wind energy systems are further developed for practical applications. → Thermodynamic characteristics of wind turbine systems through energetic and exergetic efficiencies are evaluated from January till March 2010. → Exergy efficiency describes the system irreversibility and the minimum irreversibility exists when the wind speed reaches 11 m/s. → The power production during March was about 17% higher than the month of February and 66% higher than January.

  11. Energy performance of buildings—EPBD in Greece

    International Nuclear Information System (INIS)

    Dascalaki, E.G.; Balaras, C.A.; Gaglia, A.G.; Droutsa, K.G.; Kontoyiannidis, S.

    2012-01-01

    Transposition of the European Directive on the energy performance of buildings (EPBD) in Greece was enacted in 2008 by a national law. A follow-up regulation on the energy performance in the building sector—KENAK released in 2010, outlines the overall approach in accordance to European standards and EPBD mandates. All necessary technical specifications and detailed information for the implementation of KENAK are included in four new technical guidelines prepared in 2010, which are supported by an official national software. Issues related to the energy experts are handled by presidential decrees published in 2010; over 5400 temporary energy inspectors are already in place, while permanent accreditation is in progress. Energy performance design study of new buildings for obtaining a building permit is in place since October 2010 and issuing energy performance certificates as of January 2011. This paper presents an overview of the development and current EPBD stage of implementation in Greece, along with a first assessment of the lessons learned and experiences gained. - Highlights: ► EPBD transposition in Greece is a reality. ► KENAK is the main legislative instrument for improving building energy efficiency in Greece. ► Four new technical guidelines have been published to support KENAK. ► A national software was also prepared to support implementation of KENAK. ► Temporary accreditation of 5300 energy inspectors. ► Over 20,000 energy performance certificates issued in the first five months of implementation.

  12. Missing transverse energy performance of the CMS detector

    Energy Technology Data Exchange (ETDEWEB)

    Chatrchyan, Serguei [Yerevan Physics Inst. (Armenia); et al.

    2011-09-01

    During 2010 the LHC delivered pp collisions with a centre-of-mass energy of 7 TeV. In this paper, the results of comprehensive studies of missing transverse energy as measured by the CMS detector are presented. The results cover the measurements of the scale and resolution for missing transverse energy, and the effects of multiple pp interactions within the same bunch crossings on the scale and resolution. Anomalous measurements of missing transverse energy are studied, and algorithms for their identification are described. The performances of several reconstruction algorithms for calculating missing transverse energy are compared. An algorithm, called missing-transverse-energy significance, which estimates the compatibility of the reconstructed missing transverse energy with zero, is described, and its performance is demonstrated.

  13. 2010 energy benchmarking report performance of the Canadian office sector

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2011-04-15

    In 2009, REALpac set a target of reducing energy consumption in office buildings to 20 equivalent kilowatt-hours per square foot by 2015. Following this, REALpac launched a national energy benchmarking survey to create a baseline for building energy performance across Canada; this paper provides the results of that survey. The survey was carried out using a tool which can measure energy use in a meaningful way using building characteristics data and energy use data from utility bills. The survey was conducted on 2009 data, 261 office buildings submitted their data which were then analyzed to provide trends and a baseline. Results showed a variety and diversity of performances and a 28.7 ekWh/ft2 annual mean building energy use intensity was found. This survey demonstrated that several office building owners and managers are taking steps to monitor and minimize energy use in their buildings.

  14. Missing transverse energy performance of the CMS detector

    International Nuclear Information System (INIS)

    2011-01-01

    During 2010 the LHC delivered pp collisions with a centre-of-mass energy of 7 TeV. In this paper, the results of comprehensive studies of missing transverse energy as measured by the CMS detector are presented. The results cover the measurements of the scale and resolution for missing transverse energy, and the effects of multiple pp interactions within the same bunch crossings on the scale and resolution. Anomalous measurements of missing transverse energy are studied, and algorithms for their identification are described. The performance of several reconstruction algorithms for calculating missing transverse energy are compared. An algorithm, called missing-transverse-energy significance, which estimates the compatibility of the reconstructed missing transverse energy with zero, is described, and its performance is demonstrated.

  15. Effective energy planning for improving the enterprise’s energy performance

    Directory of Open Access Journals (Sweden)

    Păunescu Carmen

    2016-09-01

    Full Text Available The global pressing need to protect the environment, save energy and reduce greenhouse gas emissions worldwide has prompted the enterprises to implementing both individual energy saving measures and a more systematic approach to improve the overall enterprise’s energy performance. Energy management is becoming a priority as enterprises strive to reduce energy costs, conform to regulatory requirements, and improve their corporate image. As such, enterprises are encouraged to manage their energy related matters in a systematic manner and a more harmonized way, to ensure continual improvement on their energy efficiency. Despite the increasing interest in energy management standards, a gap persists between energy management literature and current implementation practices. The release of the ISO 50001 international standard was meant to help the organizations develop sound energy management systems and effective process-based energy management structures that could be recognized through third-party certification. Building on the energy management literature and energy management standards, the current paper presents the essential steps the enterprises should take to practically design a sustainable energy management system. Also, by using multiple case studies of enterprises that have implemented an ISO 50001 energy management system, it introduces a structured approach that companies can use to effectively develop their energy planning and improve energy performance. The key components of the enterprise’s energy planning are discussed, as well as practical examples of energy objectives and performance indicators from various industries are offered. The paper shows that by establishing an effective energy planning system, this will efficiently meet demands for achieving energy performance indicators and international certification.

  16. Performance of a piezoelectric energy harvester in actual rain

    International Nuclear Information System (INIS)

    Wong, Voon-Kean; Ho, Jee-Hou; Chai, Ai-Bao

    2017-01-01

    When raindrops impact on the surface of a piezoelectric beam, strain energy produced by the impinging raindrop will be converted to harvestable electrical energy by the piezoelectric layers in a cantilever beam. The novelty of this study is to investigate the performance of the harvester in actual rain and provide practical insights on implementation. The influences of rain parameters such as rain rate, rainfall depth, raindrop count, and drop size distribution (DSD) are discussed in this study. The raindrops accumulated on the surface of the piezoelectric beam will form a water layer. It is described using added mass coefficient in this study. In an actual rain experiment, a piezoelectric beam with surface area of 0.0018 m 2 is able to produce 2076 μJ of energy over a duration of 301 min. The energy generation of a raindrop impact piezoelectric energy harvester is highly dependent on the rain rate. Due to the inconsistency of the energy generation, the piezoelectric energy harvester would require an integration of suitable energy storage device for continuous operation. Nevertheless, this work shows the feasibility of harvesting raindrop energy using a piezoelectric beam. - Highlights: • The performance of a piezoelectric rain energy harvester is tested in actual rain. • The energy generation is highly dependent on the rain rate. • Practical insights on the implementation of the harvester are discussed. • A total energy of 2076 μJ is generated over a duration of 301 min.

  17. 27 CFR 4.62 - Mandatory statements.

    Science.gov (United States)

    2010-04-01

    ... OF THE TREASURY LIQUORS LABELING AND ADVERTISING OF WINE Advertising of Wine § 4.62 Mandatory... responsible for its publication or broadcast. Street number and name may be omitted in the address. (b) Class... where only one type of wine is marketed under the specific brand name advertised. (2) On consumer...

  18. Mandatory School Uniforms and Freedom of Expression

    Science.gov (United States)

    Vopat, Mark C.

    2010-01-01

    On 10 December 2007 the Akron City School Board--following the precedent set by many school systems across the United States and the world--instituted a policy of mandatory school uniforms for all students in grades K-8. The measure was met with mixed reviews. While many parents supported the measure, a small group of parents from a selective,…

  19. 76 FR 34004 - Dairy Product Mandatory Reporting

    Science.gov (United States)

    2011-06-10

    ... other year. During each visit, AMS reviews applicable sales transactions records for at least the 4 most recent weeks. In some cases, AMS may review sales records for periods of up to 2 years. AMS verifies that... products to report sales information for a mandatory dairy product reporting program. The amendment further...

  20. 77 FR 8717 - Dairy Product Mandatory Reporting

    Science.gov (United States)

    2012-02-15

    ... such entity at least once every other year. During each visit, AMS reviews applicable sales transactions records for at least the 4 most recent weeks. In some cases, AMS may review sales records for up... products to report sales information for a mandatory dairy product reporting program. The amendment further...

  1. How prosody is both mandatory and optional

    NARCIS (Netherlands)

    Cutler, A.; McQueen, J.M.; Caspers, J.; Chen, Y.; Heeren, W.; Pacilly, J.; Schiller, N.O.; Zanten, E. van

    2014-01-01

    Speech signals originate as a sequence of linguistic units selected by speakers, but these units are necessarily realised in the suprasegmental dimensions of time, frequency and amplitude. For this reason prosodic structure has been viewed as a mandatory target of language processing by both

  2. 76 FR 80903 - Mandatory Declassification Review Addresses

    Science.gov (United States)

    2011-12-27

    ... John J. Kingman Road, Fort Belvoir, VA 22060-6201. (13) Missile Defense Agency. Missile Defense Agency... DEPARTMENT OF DEFENSE Office of the Secretary Mandatory Declassification Review Addresses AGENCY: Department of Defense. ACTION: Notice. SUMMARY: Pursuant to the Information Security Oversight Office's...

  3. Attendance at NHS mandatory training sessions.

    Science.gov (United States)

    Brand, Darren

    2015-02-17

    To identify factors that affect NHS healthcare professionals' attendance at mandatory training sessions. A quantitative approach was used, with a questionnaire sent to 400 randomly selected participants. A total of 122 responses were received, providing a mix of qualitative and quantitative data. Quantitative data were analysed using statistical methods. Open-ended responses were reviewed using thematic analysis. Clinical staff value mandatory training sessions highly. They are aware of the requirement to keep practice up-to-date and ensure patient safety remains a priority. However, changes to the delivery format of mandatory training sessions are required to enable staff to participate more easily, as staff are often unable to attend. The delivery of mandatory training should move from classroom-based sessions into the clinical area to maximise participation. Delivery should be assisted by local 'experts' who are able to customise course content to meet local requirements and the requirements of different staff groups. Improved arrangements to provide staff cover, for those attending training, would enable more staff to attend training sessions.

  4. Optimal Rather than Mandatory EU Company Law

    NARCIS (Netherlands)

    Hertig, G.; McCahery, J.A.

    2006-01-01

    A significant debate rages within the EU about whether to give firms the choice to opt in or out of corporate law provisions. Both sides agree that more flexibility and adaptability of legal rules to business needs is crucial. Nevertheless, and not surprisingly, many still view EU mandatory

  5. Performance maps for the control of thermal energy storage

    DEFF Research Database (Denmark)

    Finck, Christian; Li, Rongling; Zeiler, Wim

    2017-01-01

    Predictive control in building energy systems requires the integration of the building, building system, and component dynamics. The prediction accuracy of these dynamics is crucial for practical applications. This paper introduces performance maps for the control of water tanks, phase change mat...... material tanks, and thermochemical material tanks. The results show that these performance maps can fully account for the dynamics of thermal energy storage tanks.......Predictive control in building energy systems requires the integration of the building, building system, and component dynamics. The prediction accuracy of these dynamics is crucial for practical applications. This paper introduces performance maps for the control of water tanks, phase change...

  6. Performance outcomes and unwanted side effects associated with energy drinks.

    Science.gov (United States)

    Mora-Rodriguez, Ricardo; Pallarés, Jesús G

    2014-10-01

    Energy drinks are increasingly popular among athletes and others. Advertising for these products typically features images conjuring great muscle power and endurance; however, the scientific literature provides sparse evidence for an ergogenic role of energy drinks. Although the composition of energy drinks varies, most contain caffeine; carbohydrates, amino acids, herbs, and vitamins are other typical ingredients. This report analyzes the effects of energy drink ingredients on prolonged submaximal (endurance) exercise as well as on short-term strength and power (neuromuscular performance). It also analyzes the effects of energy drink ingredients on the fluid and electrolyte deficit during prolonged exercise. In several studies, energy drinks have been found to improve endurance performance, although the effects could be attributable to the caffeine and/or carbohydrate content. In contrast, fewer studies find an ergogenic effect of energy drinks on muscle strength and power. The existing data suggest that the caffeine dose given in studies of energy drinks is insufficient to enhance neuromuscular performance. Finally, it is unclear if energy drinks are the optimal vehicle to deliver caffeine when high doses are needed to improve neuromuscular performance. © 2014 International Life Sciences Institute.

  7. Energy Performance Certification of Faculty Buildings in Spain: The gap between estimated and real energy consumption

    International Nuclear Information System (INIS)

    Herrando, María; Cambra, David; Navarro, Marcos; Cruz, Lucio de la; Millán, Gema; Zabalza, Ignacio

    2016-01-01

    Highlights: • Most of the Faculty Buildings studied are within the average of CO_2 emissions. • Academic and Research buildings have a similar simulated energy consumption. • Several restrictions found in the official Energy Performance Certification tool. • Average deviation of 30% between estimated and real energy consumption. • Electrical equipment and user behaviour notably increase the energy performance gap. - Abstract: A systematic method has been established to perform and analyse in detail the Energy Performance Certification of 21 Faculty Buildings located at the University of Zaragoza (Spain), according to the transposition of Directive 2010/31/EU. First of all, the problem background and a review of the state-of-the-art of the energy certification in buildings is outlined, regarding both the actual state of the Government regulations and the studies undertaken in several countries to assess the energy performance of different types of buildings, residential and non-residential. A summary of the causes found in other studies for the discrepancies between the estimated (by simulation) and actual energy consumption is shown which is afterwards tested and compared with the results found in the present study. Thereafter, the method followed to undertake the buildings’ Energy Performance Certification is explained, and the main results found together with the discussion are detailed, comparing actual vs. estimated energy consumption in the different case studies and proposing reasons for these deviations. The energy consumption breakdown by uses for several buildings is also analysed, and potential improvements for the simulation software are assessed.

  8. Computational Fluid Dynamics and Building Energy Performance Simulation

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm; Tryggvason, T.

    1998-01-01

    An interconnection between a building energy performance simulation program and a Computational Fluid Dynamics program (CFD) for room air distribution will be introduced for improvement of the predictions of both the energy consumption and the indoor environment. The building energy performance...... simulation program requires a detailed description of the energy flow in the air movement which can be obtained by a CFD program. The paper describes an energy consumption calculation in a large building, where the building energy simulation program is modified by CFD predictions of the flow between three...... zones connected by open areas with pressure and buoyancy driven air flow. The two programs are interconnected in an iterative procedure. The paper shows also an evaluation of the air quality in the main area of the buildings based on CFD predictions. It is shown that an interconnection between a CFD...

  9. Solar energy photovoltaic technology: proficiency and performance; L'energie solaire maitrise et performance photovoltaiques

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2006-07-01

    Total is committed to making the best possible of the planet's fossil fuel reserves while fostering the emergence of other solutions, notably by developing effective alternatives. Total involves in photovoltaics when it founded in 1983 Total Energies, renamed Tenesol in 2005, a world leader in the design and installation of photovoltaic solar power systems. This document presents Total's activities in the domain: the global challenge of energy sources and the environment, the energy collecting by photovoltaic electricity, the silicon technology for cell production, solar panels and systems to distribute energy, research and development to secure the future. (A.L.B.)

  10. Energy Performance of Buildings - The European Approach to Sustainability

    DEFF Research Database (Denmark)

    Heiselberg, Per

    2006-01-01

    This paper presents the European approach to improve sustainability in the building sector, which has a very high potential for considerable reduction of energy consumption in the coming years. By approving the Energy Performance in Buildings Directive the European Union has taken a strong...... leadership role in promoting energy efficiency in buildings in Europe, that will be the most powerful instrument developed to date for the building sector in Europe....

  11. Performance of the electron energy-loss spectrometer

    International Nuclear Information System (INIS)

    Tanaka, H.; Huebner, R.H.

    1977-01-01

    Performance characteristics of the electron energy-loss spectrometer incorporating a new high-resolution hemispherical monochromator are reported. The apparatus achieved an energy-resolution of 25 meV in the elastic scattering mode, and angular distributions of elastically scattered electrons were in excellent agreement with previous workers. Preliminary energy-loss spectra for several atmospheric gases demonstrate the excellent versatility and stable operation of the improved system. 12 references

  12. MODELING SIMULATION AND PERFORMANCE STUDY OF GRIDCONNECTED PHOTOVOLTAIC ENERGY SYSTEM

    OpenAIRE

    Nagendra K; Karthik J; Keerthi Rao C; Kumar Raja Pemmadi

    2017-01-01

    This paper presents Modeling Simulation of grid connected Photovoltaic Energy System and performance study using MATLAB/Simulink. The Photovoltaic energy system is considered in three main parts PV Model, Power conditioning System and Grid interface. The Photovoltaic Model is inter-connected with grid through full scale power electronic devices. The simulation is conducted on the PV energy system at normal temperature and at constant load by using MATLAB.

  13. Evaluating energy performance in non-domestic buildings : a review

    NARCIS (Netherlands)

    Borgstein, E.H.; Lamberts, R.; Hensen, J.L.M.

    2016-01-01

    Evaluation methods can be used to determine what constitutes good energy performance in a building. With an increasing focus on energy use of buildings worldwide, this evaluation assumes a fundamental importance. This paper provides a comprehensive review of the available methods for analysing,

  14. On the safety performance of the advanced nuclear energy systems

    International Nuclear Information System (INIS)

    Li Shounan

    1999-01-01

    Some features on the safety performances of the Advanced Nuclear Energy Systems are discussed. The advantages and some peculiar problems on the safety of Advanced Nuclear Energy Systems with subcritical nuclear reactor driven by external neutron sources are also pointed out in comparison with conventional nuclear reactors

  15. Performance of cryogenic thermoelectric generators in LNG cold energy utilization

    International Nuclear Information System (INIS)

    Sun Wei; Hu Peng; Chen Zeshao; Jia Lei

    2005-01-01

    The cold energy of liquefied natural gas (LNG) is generally wasted when the LNG is extracted for utilization. This paper proposes cryogenic thermoelectric generators to recover this cold energy. The theoretical performance of the generator has been analyzed. An analytical method and numerical method of calculation of the optimum parameters of the generator have been demonstrated

  16. Performance gaps in energy consumption : household groups and building characteristics

    NARCIS (Netherlands)

    van den Brom, P.I.; Meijer, A.; Visscher, H.J.

    2017-01-01

    The difference between actual and calculated energy is called the ‘energy-performance gap’. Possible explanations for this gap are construction mistakes, improper adjusting of equipment, excessive simplification in simulation models and occupant behaviour. Many researchers and governmental

  17. Energy consumption performance analysis of electrical mitad at ...

    African Journals Online (AJOL)

    The Injera baking electrical mitad is the most energy-consuming device in every household in Ethiopia. This research presents a detail engineering study on the energy-consumption performance of existing electrical mitad in Mekelle city. The research work considered thirty-one electrical mitad from different workshops in ...

  18. Performance and Energy Metabolism by Broiler Chickens Fed Maize ...

    African Journals Online (AJOL)

    Studies were conducted to evaluate the effect of replacing maize grain with different dietary levels of maize and millet offals on performance and energy metabolism in broiler chickens. Proximate composition and metabolizable energy (ME) values were determined. Feeding trial was also conducted to comparemaize and ...

  19. Enabling Detailed Energy Analyses via the Technology Performance Exchange: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Studer, D.; Fleming, K.; Lee, E.; Livingood, W.

    2014-08-01

    One of the key tenets to increasing adoption of energy efficiency solutions in the built environment is improving confidence in energy performance. Current industry practices make extensive use of predictive modeling, often via the use of sophisticated hourly or sub-hourly energy simulation programs, to account for site-specific parameters (e.g., climate zone, hours of operation, and space type) and arrive at a performance estimate. While such methods are highly precise, they invariably provide less than ideal accuracy due to a lack of high-quality, foundational energy performance input data. The Technology Performance Exchange was constructed to allow the transparent sharing of foundational, product-specific energy performance data, and leverages significant, external engineering efforts and a modular architecture to efficiently identify and codify the minimum information necessary to accurately predict product energy performance. This strongly-typed database resource represents a novel solution to a difficult and established problem. One of the most exciting benefits is the way in which the Technology Performance Exchange's application programming interface has been leveraged to integrate contributed foundational data into the Building Component Library. Via a series of scripts, data is automatically translated and parsed into the Building Component Library in a format that is immediately usable to the energy modeling community. This paper (1) presents a high-level overview of the project drivers and the structure of the Technology Performance Exchange; (2) offers a detailed examination of how technologies are incorporated and translated into powerful energy modeling code snippets; and (3) examines several benefits of this robust workflow.

  20. A New Model to Simulate Energy Performance of VRF Systems

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Tianzhen; Pang, Xiufeng; Schetrit, Oren; Wang, Liping; Kasahara, Shinichi; Yura, Yoshinori; Hinokuma, Ryohei

    2014-03-30

    This paper presents a new model to simulate energy performance of variable refrigerant flow (VRF) systems in heat pump operation mode (either cooling or heating is provided but not simultaneously). The main improvement of the new model is the introduction of the evaporating and condensing temperature in the indoor and outdoor unit capacity modifier functions. The independent variables in the capacity modifier functions of the existing VRF model in EnergyPlus are mainly room wet-bulb temperature and outdoor dry-bulb temperature in cooling mode and room dry-bulb temperature and outdoor wet-bulb temperature in heating mode. The new approach allows compliance with different specifications of each indoor unit so that the modeling accuracy is improved. The new VRF model was implemented in a custom version of EnergyPlus 7.2. This paper first describes the algorithm for the new VRF model, which is then used to simulate the energy performance of a VRF system in a Prototype House in California that complies with the requirements of Title 24 ? the California Building Energy Efficiency Standards. The VRF system performance is then compared with three other types of HVAC systems: the Title 24-2005 Baseline system, the traditional High Efficiency system, and the EnergyStar Heat Pump system in three typical California climates: Sunnyvale, Pasadena and Fresno. Calculated energy savings from the VRF systems are significant. The HVAC site energy savings range from 51 to 85percent, while the TDV (Time Dependent Valuation) energy savings range from 31 to 66percent compared to the Title 24 Baseline Systems across the three climates. The largest energy savings are in Fresno climate followed by Sunnyvale and Pasadena. The paper discusses various characteristics of the VRF systems contributing to the energy savings. It should be noted that these savings are calculated using the Title 24 prototype House D under standard operating conditions. Actual performance of the VRF systems for real

  1. Super Energy Savings Performance Contracts: Federal Energy Management Program (FEMP) Program Overview (revision)

    International Nuclear Information System (INIS)

    Pitchford, P.

    2001-01-01

    This four-page publication describes the U.S. Department of Energy's (DOE's) streamlined energy savings performance contracting, or ''Super ESPC,'' process, which is managed by DOE's Federal Energy Management Program (FEMP). Under a Super ESPC, a qualifying energy service company (ESCO) from the private sector pays for energy efficiency improvements or advanced renewable energy technologies (e.g., photovoltaic systems, wind turbines, or geothermal heat pumps, among others) for a facility of a government agency. The ESCO is then repaid over time from the agency's resulting energy cost savings. Delivery orders under these contracts specify the level of performance (energy savings) and the repayment schedule; the contract term can be up to 25 years, although many Super ESPCs are for about 10 years or less

  2. Measure Guideline. Energy-Efficient Window Performance and Selection

    Energy Technology Data Exchange (ETDEWEB)

    Carmody, John [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR; Haglund, Kerry [Univ. of Minnesota, St. Paul, MN (United States). NorthernSTAR

    2012-11-01

    This document provides guidelines for the selection of energy-efficient windows in new and existing residential construction in all U.S. climate zones. It includes information on window products, their attributes and performance. It provides cost/benefit information on window energy savings as well as information on non-energy benefits such as thermal comfort and reduced HVAC demands. The report also provides information on energy impacts of design decisions such as window orientation, total glazing area and shading devices and conditions. Information on resources for proper window installation is included as well.

  3. Deep Energy Retrofit Performance Metric Comparison: Eight California Case Studies

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Fisher, Jeremy [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Less, Brennan [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-06-01

    In this paper we will present the results of monitored annual energy use data from eight residential Deep Energy Retrofit (DER) case studies using a variety of performance metrics. For each home, the details of the retrofits were analyzed, diagnostic tests to characterize the home were performed and the homes were monitored for total and individual end-use energy consumption for approximately one year. Annual performance in site and source energy, as well as carbon dioxide equivalent (CO2e) emissions were determined on a per house, per person and per square foot basis to examine the sensitivity to these different metrics. All eight DERs showed consistent success in achieving substantial site energy and CO2e reductions, but some projects achieved very little, if any source energy reduction. This problem emerged in those homes that switched from natural gas to electricity for heating and hot water, resulting in energy consumption dominated by electricity use. This demonstrates the crucial importance of selecting an appropriate metric to be used in guiding retrofit decisions. Also, due to the dynamic nature of DERs, with changes in occupancy, size, layout, and comfort, several performance metrics might be necessary to understand a project’s success.

  4. Energy Performance Indicators in the Swedish Building Procurement Process

    Directory of Open Access Journals (Sweden)

    Ingrid Allard

    2017-10-01

    Full Text Available In Sweden, all new buildings need to comply with the National Board of Housing, Building and Planning’s requirement on specific purchased energy (kWh/m2. Accordingly, this indicator is often used to set design criteria in the building procurement process. However, when energy use is measured in finished buildings, the measurements often deviate significantly from the design calculations. The measured specific purchased energy does not necessarily reflect the responsibility of the building contractor, as it is influenced by the building operation, user behavior and climate. Therefore, Swedish building practitioners may prefer other indicators for setting design criteria in the building procurement process. The aim of this study was twofold: (i to understand the Swedish building practitioners’ perspectives and opinions on seven building energy performance indicators (envelope air leakage, U-values for different building parts, average U-value, specific heat loss, heat loss coefficient, specific net energy, and specific purchased energy; and (ii to understand the consequences for the energy performance of multi-family buildings of using the studied indicators to set criteria in the procurement process. The study involved a Delphi approach and simulations of a multi-family case study building. The studied indicators were discussed in terms of how they may meet the needs of the building practitioners when used to set building energy performance criteria in the procurement process.

  5. Home Performance with ENERGY STAR(R) Exchange

    Energy Technology Data Exchange (ETDEWEB)

    2003-10-01

    Handout for the Energy and Environmental Building Association's Building Solutions 2003 Conference and Expo: Chicago, Illinois, October 2003 The following summaries, provided by implementers of ''Home Performance with ENERGY STAR{reg_sign}'' around the country, are for use in the October 15 discussion during the Energy & Environmental Building Association (EEBA) Building Solutions, 2003 Conference in Chicago. The summaries and session discussions provide an overview of ''Home Performance with ENERGY STAR'', along with results and lessons learned from existing ''Home Performance'' implementers in New York, Wisconsin, Massachusetts, California, and Kansas City. Five future pilot projects set to begin in Georgia/Alabama, Idaho, Missouri, New Jersey and Texas will also be presented and discussed. Session topics will include the use of different training approaches, methods of quality assurance, and the role contractor certification plays in several of the programs. The session will conclude with a roundtable discussion of Home Performance issues by current and emerging implementers, with time for participant questions. ''Home Performance with ENERGY STAR'' uses the growing awareness and credibility of the ENERGY STAR brand to encourage and facilitate whole-house energy improvements in existing homes through self-sustaining energy efficiency programs. Whether you're a state energy official, utility program manager, contractor training professional or efficiency program implementer, you're sure to benefit from the unique presentations and networking opportunities that this session will offer.

  6. 75 FR 57669 - Mandatory Reporting of Greenhouse Gases

    Science.gov (United States)

    2010-09-22

    ... Mandatory Reporting of Greenhouse Gases AGENCY: Environmental Protection Agency (EPA). ACTION: Final rule. SUMMARY: This action amends the Final Mandatory Reporting of Greenhouse Gases Rule to require reporters... Numbers GHG greenhouse gas GHGRP Greenhouse Gas Reporting Program HCFC hydrochlorofluorocarbon HFC...

  7. How much information disclosure of building energy performance is necessary?

    International Nuclear Information System (INIS)

    Hsu, David

    2014-01-01

    Many different governments have begun to require disclosure of building energy performance, in order to allow owners and prospective buyers to incorporate this information into their investment decisions. These policies, known as disclosure or information policies, require owners to benchmark their buildings and sometimes conduct engineering audits. However, given substantial variation in the cost to disclose different types of information, it is natural to ask: how much and what kind of information about building energy performance should be disclosed, and for what purposes? To answer this question, this paper assembles and cleans a comprehensive panel dataset of New York City multifamily buildings, and analyzes its predictive power using a Bayesian multilevel regression model. Analysis of variance (ANOVA) reveals that building-level variation is the most important factor in explaining building energy use, and that there are few, if any, relationships of building systems to observed energy use. This indicates that disclosure laws requiring benchmarking data may be relatively more useful than engineering audits in explaining the observed energy performance of existing buildings. These results should inform the further development of information disclosure laws. - Highlights: • A comprehensive panel dataset of energy performance and building characteristics was assembled and cleaned. • The effectiveness of the disclosed information to predict building energy performance was tested using a regression model. • Building-level variation has a greater effect than any building characteristic or systems. • Benchmarking data alone predicts energy performance equally as well as both benchmarking and engineering audit data together, and better than audit data alone

  8. Long term energy performance analysis of Egbin thermal power ...

    African Journals Online (AJOL)

    This study is aimed at providing an energy performance analysis of Egbin thermal power plant. The plant operates on Regenerative Rankine cycle with steam as its working fluid .The model equations were formulated based on some performance parameters used in power plant analysis. The considered criteria were plant ...

  9. Is mandatory research ethics reviewing ethical?

    Science.gov (United States)

    Dyck, Murray; Allen, Gary

    2013-08-01

    Review boards responsible for vetting the ethical conduct of research have been criticised for their costliness, unreliability and inappropriate standards when evaluating some non-medical research, but the basic value of mandatory ethical review has not been questioned. When the standards that review boards use to evaluate research proposals are applied to review board practices, it is clear that review boards do not respect researchers or each other, lack merit and integrity, are not just and are not beneficent. The few benefits of mandatory ethical review come at a much greater, but mainly hidden, social cost. It is time that responsibility for the ethical conduct of research is clearly transferred to researchers, except possibly in that small proportion of cases where prospective research participants may be so intrinsically vulnerable that their well-being may need to be overseen.

  10. A libertarian case for mandatory vaccination.

    Science.gov (United States)

    Brennan, Jason

    2018-01-01

    This paper argues that mandatory, government-enforced vaccination can be justified even within a libertarian political framework. If so, this implies that the case for mandatory vaccination is very strong indeed as it can be justified even within a framework that, at first glance, loads the philosophical dice against that conclusion. I argue that people who refuse vaccinations violate the 'clean hands principle', a (in this case, enforceable) moral principle that prohibits people from participating in the collective imposition of unjust harm or risk of harm. In a libertarian framework, individuals may be forced to accept certain vaccines not because they have an enforceable duty to serve the common, and not because cost-benefit analysis recommends it, but because anti-vaxxers are wrongfully imposing undue harm upon others. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  11. Energy management in production: A novel method to develop key performance indicators for improving energy efficiency

    International Nuclear Information System (INIS)

    May, Gökan; Barletta, Ilaria; Stahl, Bojan; Taisch, Marco

    2015-01-01

    Highlights: • We propose a 7-step methodology to develop firm-tailored energy-related KPIs (e-KPIs). • We provide a practical guide for companies to identify their most important e-KPIs. • e-KPIs support identification of energy efficiency improvement areas in production. • The method employs an action plan for achieving energy saving targets. • The paper strengthens theoretical base for energy-based decision making in manufacturing. - Abstract: Measuring energy efficiency performance of equipments, processes and factories is the first step to effective energy management in production. Thus, enabled energy-related information allows the assessment of the progress of manufacturing companies toward their energy efficiency goals. In that respect, the study addresses this challenge where current industrial approaches lack the means and appropriate performance indicators to compare energy-use profiles of machines and processes, and for the comparison of their energy efficiency performance to that of competitors’. Focusing on this challenge, the main objective of the paper is to present a method which supports manufacturing companies in the development of energy-based performance indicators. For this purpose, we provide a 7-step method to develop production-tailored and energy-related key performance indicators (e-KPIs). These indicators allow the interpretation of cause-effect relationships and therefore support companies in their operative decision-making process. Consequently, the proposed method supports the identification of weaknesses and areas for energy efficiency improvements related to the management of production and operations. The study therefore aims to strengthen the theoretical base necessary to support energy-based decision making in manufacturing industries

  12. The performance of energy efficient residential building envelope systems

    Energy Technology Data Exchange (ETDEWEB)

    Proskiw, G.

    1996-08-01

    The adequacy and durability of residential building envelope systems under actual field conditions were evaluated. A building envelope offers protection from cold, heat, moisture, wind and noise. However, they are exposed to thermal, structural, and moisture stresses and their performance can degrade over time. Envelope performance was evaluated at 20 energy efficient and four conventional, detached modern homes in Winnipeg, Canada. The three complementary measurement tools were wood moisture content (WMC) of framing members, thermographic examinations, and airtightness tests. As expected, energy efficient building envelope systems performed better than the conventional systems. No evidence of envelope degradation was found in any of the energy efficient houses. The building envelopes using polyethylene air barriers performed slightly better than those which used the airtight drywall approach, although both were considered satisfactory. WMC levels were a bit lower in the polyethylene-clad house. 1 ref., 1 tab.

  13. Dynamic performance analysis of two regional Nuclear Hybrid Energy Systems

    International Nuclear Information System (INIS)

    Garcia, Humberto E.; Chen, Jun; Kim, Jong S.; Vilim, Richard B.; Binder, William R.; Bragg Sitton, Shannon M.; Boardman, Richard D.; McKellar, Michael G.; Paredis, Christiaan J.J.

    2016-01-01

    In support of more efficient utilization of clean energy generation sources, including renewable and nuclear options, HES (hybrid energy systems) can be designed and operated as FER (flexible energy resources) to meet both electrical and thermal energy needs in the electric grid and industrial sectors. These conceptual systems could effectively and economically be utilized, for example, to manage the increasing levels of dynamic variability and uncertainty introduced by VER (variable energy resources) such as renewable sources (e.g., wind, solar), distributed energy resources, demand response schemes, and modern energy demands (e.g., electric vehicles) with their ever changing usage patterns. HES typically integrate multiple energy inputs (e.g., nuclear and renewable generation) and multiple energy outputs (e.g., electricity, gasoline, fresh water) using complementary energy conversion processes. This paper reports a dynamic analysis of two realistic HES including a nuclear reactor as the main baseload heat generator and to assess the local (e.g., HES owners) and system (e.g., the electric grid) benefits attainable by their application in scenarios with multiple commodity production and high renewable penetration. It is performed for regional cases – not generic examples – based on available resources, existing infrastructure, and markets within the selected regions. This study also briefly addresses the computational capabilities developed to conduct such analyses. - Highlights: • Hybrids including renewables can operate as dispatchable flexible energy resources. • Nuclear energy can address high variability and uncertainty in energy systems. • Nuclear hybrids can reliably provide grid services over various time horizons. • Nuclear energy can provide operating reserves and grid inertia under high renewables. • Nuclear hybrids can greatly reduce GHG emissions and support grid and industry needs.

  14. Integrated energy system for a high performance building

    Science.gov (United States)

    Jaczko, Kristen

    Integrated energy systems have the potential to reduce of the energy consumption of residential buildings in Canada. These systems incorporate components to meet the building heating, cooling and domestic hot water load into a single system in order to reduce energy losses. An integrated energy system, consisting of a variable speed heat pump, cold and hot thermal storage tanks, a photovoltaic/thermal (PV/T) collector array and a battery bank, was designed for the Queen's Solar Design Team's (QSDT) test house. The system uses a radiant floor to provide space- heating and sensible cooling and a dedicated outdoor air system provides ventilation and dehumidifies the incoming fresh air. The test house, the Queen's Solar Education Centre (QSEC), and the integrated energy system were both modelled in TRNSYS. Additionally, a new TRNSYS Type was developed to model the PV/T collectors, enabling the modeling of the collection of energy from the ambient air. A parametric study was carried out in TRNSYS to investigate the effect of various parameters on the overall energy performance of the system. These parameters included the PV/T array size and the slope of the collectors, the heat pump source and load-side inlet temperature setpoints, the compressor speed control and the size of the thermal storage tanks and the battery bank. The controls of the heat pump were found to have a large impact on the performance of the integrated energy system. For example, a low evaporator setpoint improved the overall free energy ratio (FER) of the system but the heat pump performance was lowered. Reducing the heat loss of the PV/T panels was not found to have a large effect on the system performance however, as the heat pump is able to lower the inlet collector fluid temperature, thus reducing thermal losses. From the results of the sensitivity study, a recommended system model was created and this system had a predicted FER of 77.9% in Kingston, Ontario, neglecting the energy consumption of

  15. Impact of neighborhood design on energy performance and GHG emissions

    International Nuclear Information System (INIS)

    Hachem, Caroline

    2016-01-01

    Highlights: • Energy use and GHG emissions of different neighborhood designs are investigated. • Improving buildings energy performance reduces energy use and GHG emissions by 75%. • Density as isolated factor has limited effect on transport on per capita basis. • Distance to central business district impacts transport GHG emission significantly. - Abstract: This paper presents an innovative and holistic approach to the analysis of the impact of selected design parameters of a new solar community on its environmental performance, in terms of energy efficiency and carbon footprint (green-house gas (GHG) emissions). The design parameters include energy performance level of buildings, density, type of the neighborhood (mixed-use vs residential), location of the commercial center relative to residential areas and the design of the streets. Energy performance is measured as the balance between overall energy consumption for building operations (assuming an all-electric neighborhood) and electricity generation potential through integration of PV panels on available roof surfaces. Greenhouse gas emissions are those associated with building operations and transport. Results of simulations carried out on prototype neighborhoods located in the vicinity of Calgary, Alberta, Canada indicate that, while adopting high-energy efficiency measures can reduce the buildings’ impact by up to 75% in terms of energy consumption and GHG emissions, transport still has a large environmental impact. The parameters of highest impact on transport and its associated GHG emissions are the design of the neighborhood and the distance to the business center. Density, as isolated parameter, has a modest effect on the selected mode of transportation, in terms of using private or public transportation. While this study relates to a specific location and a range of design assumptions, the methodology employed can serve as a template for evaluating design alternatives of new sustainable

  16. 75 FR 66433 - Mandatory Reporting of Greenhouse Gases

    Science.gov (United States)

    2010-10-28

    ... Part II Environmental Protection Agency 40 CFR Parts 86 and 98 Mandatory Reporting of Greenhouse...; FRL-9213-5] RIN 2060-A079 Mandatory Reporting of Greenhouse Gases AGENCY: Environmental Protection... Mandatory Greenhouse Gas Reporting rule to correct certain technical and editorial errors that have been...

  17. 76 FR 73885 - Mandatory Reporting of Greenhouse Gases

    Science.gov (United States)

    2011-11-29

    ... Mandatory Reporting of Greenhouse Gases; Final Rule #0;#0;Federal Register / Vol. 76, No. 229 / Tuesday... 98 [EPA-HQ-OAR-2011-0147; FRL-9493-9] RIN 2060-AQ85 Mandatory Reporting of Greenhouse Gases AGENCY... the Mandatory Reporting of Greenhouse Gases Rule to correct certain technical and editorial errors...

  18. 75 FR 33949 - Mandatory Reporting of Greenhouse Gases

    Science.gov (United States)

    2010-06-15

    ... Part III Environmental Protection Agency 40 CFR Parts 86 and 98 Mandatory Reporting of Greenhouse...; FRL-9158-6] RIN 2060-A079 Mandatory Reporting of Greenhouse Gases AGENCY: Environmental Protection... Final Mandatory Greenhouse Gas Reporting rule (2009 Final MRR) to correct certain technical and...

  19. 75 FR 18455 - Mandatory Reporting of Greenhouse Gases

    Science.gov (United States)

    2010-04-12

    ... Mandatory Reporting of Greenhouse Gases AGENCY: Environmental Protection Agency (EPA). ACTION: Proposed rule amendment. SUMMARY: EPA is proposing to amend the Mandatory Greenhouse Gas (GHG) Reporting Rule, to require.... The Mandatory GHG Reporting Rule requires greenhouse gas emitting facilities and suppliers of fuels...

  20. 76 FR 47391 - Mandatory Reporting of Greenhouse Gases

    Science.gov (United States)

    2011-08-04

    ... Mandatory Reporting of Greenhouse Gases; Proposed Rule #0;#0;Federal Register / Vol. 76, No. 150 / Thursday...-HQ-OAR-2011-0147; FRL-9443-1] RIN 2060-AQ85 Mandatory Reporting of Greenhouse Gases AGENCY... provisions in the Mandatory Reporting of Greenhouse Gases Rule to correct certain technical and editorial...

  1. 7 CFR 59.302 - Mandatory weekly reporting for lambs.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Mandatory weekly reporting for lambs. 59.302 Section... (CONTINUED) LIVESTOCK MANDATORY REPORTING Lamb Reporting § 59.302 Mandatory weekly reporting for lambs. (a... domestic from imported market purchases: (1) The quantity of lambs purchased through a negotiated purchase...

  2. 7 CFR 59.301 - Mandatory Daily Reporting for Lambs.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Mandatory Daily Reporting for Lambs. 59.301 Section 59... (CONTINUED) LIVESTOCK MANDATORY REPORTING Lamb Reporting § 59.301 Mandatory Daily Reporting for Lambs. (a) In... prices for lambs (per hundredweight) established on that day as F.O.B. feedlot or delivered at the plant...

  3. Performance of fuel cell for energy supply of passive house

    Energy Technology Data Exchange (ETDEWEB)

    Badea, G.; Felseghi, R. A., E-mail: Raluca.FELSEGHI@insta.utcluj.ro; Mureşan, D.; Naghiu, G. [Technical University of Cluj-Napoca, Building Services Engineering Department, Bd. December 21, no. 128-130, 400600, Cluj-Napoca (Romania); Răboacă, S. M. [National R& D Institute for Cryogenic and Isotopic Technologies, str. Uzinei, no. 4, Rm. Vălcea, 240050 (Romania); Aşchilean, I. [SC ACI Cluj SA, Avenue Dorobanţilor, no. 70, 400609, Cluj-Napoca (Romania)

    2015-12-23

    Hydrogen technology and passive house represent two concepts with a remarkable role for the efficiency and decarbonisation of energy systems in the residential buildings area. Through design and functionality, the passive house can make maximum use of all available energy resources. One of the solutions to supply energy of these types of buildings is the fuel cell, using this technology integrated into a system for generating electricity from renewable primary sources, which take the function of backup power (energy reserve) to cover peak load and meteorological intermittents. In this paper is presented the results of the case study that provide an analysis of the energy, environmental and financial performances regarding energy supply of passive house by power generation systems with fuel cell fed with electrolytic hydrogen produced by harnessing renewable energy sources available. Hybrid systems have been configured and operate in various conditions of use for five differentiated locations according to the main areas of solar irradiation from the Romanian map. Global performance of hybrid systems is directly influenced by the availability of renewable primary energy sources - particular geo-climatic characteristics of the building emplacement.

  4. Renewable Energy Certificate and Perform, Achieve, Trade mechanisms to enhance the energy security for India

    International Nuclear Information System (INIS)

    Kumar, Rajesh; Agarwala, Arun

    2013-01-01

    The Renewable Energy Certificate and Perform Achieve Trade mechanisms in India are designed to target energy generation and saving, respectively, in line with Clean Development Mechanism implemented by United Nations Framework Convention on Climate Change. The Renewable Energy Certificate System is a voluntary regulation in India for renewable energy generators and is designed for effective implementation of inter-state transactions by introducing the Renewable Purchase Obligation regulation for consumers and a flexible trading platform for transactions across the country. Another initiative, the Perform Achieve Trade scheme, is an enhanced energy efficiency trading mechanism based on consumption targets that require large energy user sectors to improve efficiency by 1–2% per year. The Perform Achieve Trade programme has introduced mechanisms for the identification of industry sector, designated customer, specific energy consumption and target setting. The Perform Achieve Trade design issues are in test phase in the first cycle of the scheme which will run from 2012 to 2015. This paper discusses key design issues about boundary and target setting for Renewable Energy Certificate and Perform Achieve Trade energy saving certificate (ESCert) A data sharing and trading mechanism for Perform Achieve Trade is also proposed for review and coordination among regulator, designated consumers and traders in the market. - Highlights: ► Renewable Energy Certificate’ and ‘Perform Achieve Trade’ are energy certification programmes. ► REC and PAT programme implementation and the institutional network work are presented. ► The trading and communication network propose for possible linkage between REC, PAT and CDM. ► Independent associations in parallel with CERC and BEE are redefined for two tier review of scheme

  5. Predicting energy performance of a net-zero energy building: A statistical approach

    International Nuclear Information System (INIS)

    Kneifel, Joshua; Webb, David

    2016-01-01

    Highlights: • A regression model is applied to actual energy data from a net-zero energy building. • The model is validated through a rigorous statistical analysis. • Comparisons are made between model predictions and those of a physics-based model. • The model is a viable baseline for evaluating future models from the energy data. - Abstract: Performance-based building requirements have become more prevalent because it gives freedom in building design while still maintaining or exceeding the energy performance required by prescriptive-based requirements. In order to determine if building designs reach target energy efficiency improvements, it is necessary to estimate the energy performance of a building using predictive models and different weather conditions. Physics-based whole building energy simulation modeling is the most common approach. However, these physics-based models include underlying assumptions and require significant amounts of information in order to specify the input parameter values. An alternative approach to test the performance of a building is to develop a statistically derived predictive regression model using post-occupancy data that can accurately predict energy consumption and production based on a few common weather-based factors, thus requiring less information than simulation models. A regression model based on measured data should be able to predict energy performance of a building for a given day as long as the weather conditions are similar to those during the data collection time frame. This article uses data from the National Institute of Standards and Technology (NIST) Net-Zero Energy Residential Test Facility (NZERTF) to develop and validate a regression model to predict the energy performance of the NZERTF using two weather variables aggregated to the daily level, applies the model to estimate the energy performance of hypothetical NZERTFs located in different cities in the Mixed-Humid Climate Zone, and compares these

  6. Actual energy consumption in dwellings. The effect of energy performance regulations and occupant behaviour

    Energy Technology Data Exchange (ETDEWEB)

    Guerra Santin, O.

    2010-10-19

    Residential buildings have continuously improved in energy efficiency, partly as a consequence of the introduction of energy regulations in many countries. Although better thermal properties and systems efficiency have lowered energy consumption for space heating in recent decades, substantial differences in energy consumption in similar dwellings are still being observed. These differences in consumption are thought to be caused by differences in occupancy patterns, by quality of construction and by rebound effects. This research addresses the effect of energy performance regulations and occupant behavior on energy consumption for space and water heating in dwellings built after the introduction of the energy performance regulations in the Netherlands. The results of this research show that improving the energy efficiency of buildings alone is not enough to decrease that energy consumption. The large differences found in the use of dwellings indicate that, especially in energy efficient houses, occupant behavior provides an opportunity for further reductions in the energy consumption for space heating which could boost the efforts to conserve energy worldwide.

  7. Accelerating the energy retrofit of commercial buildings using a database of energy efficiency performance

    International Nuclear Information System (INIS)

    Lee, Sang Hoon; Hong, Tianzhen; Piette, Mary Ann; Sawaya, Geof; Chen, Yixing; Taylor-Lange, Sarah C.

    2015-01-01

    Small and medium-sized commercial buildings can be retrofitted to significantly reduce their energy use, however it is a huge challenge as owners usually lack of the expertise and resources to conduct detailed on-site energy audit to identify and evaluate cost-effective energy technologies. This study presents a DEEP (database of energy efficiency performance) that provides a direct resource for quick retrofit analysis of commercial buildings. DEEP, compiled from the results of about ten million EnergyPlus simulations, enables an easy screening of ECMs (energy conservation measures) and retrofit analysis. The simulations utilize prototype models representative of small and mid-size offices and retails in California climates. In the formulation of DEEP, large scale EnergyPlus simulations were conducted on high performance computing clusters to evaluate hundreds of individual and packaged ECMs covering envelope, lighting, heating, ventilation, air-conditioning, plug-loads, and service hot water. The architecture and simulation environment to create DEEP is flexible and can expand to cover additional building types, additional climates, and new ECMs. In this study DEEP is integrated into a web-based retrofit toolkit, the Commercial Building Energy Saver, which provides a platform for energy retrofit decision making by querying DEEP and unearthing recommended ECMs, their estimated energy savings and financial payback. - Highlights: • A DEEP (database of energy efficiency performance) supports building retrofit. • DEEP is an SQL database with pre-simulated results from 10 million EnergyPlus runs. • DEEP covers 7 building types, 6 vintages, 16 climates, and 100 energy measures. • DEEP accelerates retrofit of small commercial buildings to save energy use and cost. • DEEP can be expanded and integrated with third-party energy software tools.

  8. Mandatory reporting of greenhouse gas emissions from buildings: Stakeholders’ opinions in Hong Kong

    International Nuclear Information System (INIS)

    Lai, Joseph H.K.

    2014-01-01

    Mandatory reporting of greenhouse gas (GHG) emissions, which is intended to help combat global warming, has been increasingly implemented across the world. For buildings in Hong Kong, however, GHG reporting remains entirely voluntary even though the government has issued a set of guidelines to facilitate building owners and managers to quantify GHG emissions from buildings. Aimed at understanding stakeholders’ opinions on whether, and to what extent, the GHG reporting should be made mandatory, a study involving a questionnaire survey was carried out. Analysis of the opinions revealed that the majority supported making the reporting mandatory for office, hotel/hostel, and industrial buildings. Generally more support was received from those who were highly experienced, employees of non-government public organisations, academics/researchers, or qualified carbon/energy auditors. Their agreement on requiring reporting of activities under scopes 1 and 2 of the GHG Protocol was stronger than that for the scope 3 activities. Reporting of paper waste disposal attracted the weakest support. The reasons for not supporting the mandatory policy, including resource constraint and financial and knowledge barriers that confront the stakeholders, were identified. The findings of this study serve as reference for energy policy makers. - Highlights: • Majority supported mandatory reporting for office and hotel/hostel buildings. • More support was given for reporting of scopes 1 and 2 of the GHG Protocol. • Reporting for paper waste disposal received the weakest support. • Main hurdles were resource constraint and financial and knowledge barriers

  9. Sensitivity analysis of energy demands on performance of CCHP system

    International Nuclear Information System (INIS)

    Li, C.Z.; Shi, Y.M.; Huang, X.H.

    2008-01-01

    Sensitivity analysis of energy demands is carried out in this paper to study their influence on performance of CCHP system. Energy demand is a very important and complex factor in the optimization model of CCHP system. Average, uncertainty and historical peaks are adopted to describe energy demands. The mix-integer nonlinear programming model (MINLP) which can reflect the three aspects of energy demands is established. Numerical studies are carried out based on energy demands of a hotel and a hospital. The influence of average, uncertainty and peaks of energy demands on optimal facility scheme and economic advantages of CCHP system are investigated. The optimization results show that the optimal GT's capacity and economy of CCHP system mainly lie on the average energy demands. Sum of capacities of GB and HE is equal to historical heating demand peaks, and sum of capacities of AR and ER are equal to historical cooling demand peaks. Maximum of PG is sensitive with historical peaks of energy demands and not influenced by uncertainty of energy demands, while the corresponding influence on DH is adverse

  10. Energy performance and consumption for biogas heat pump air conditioner

    Energy Technology Data Exchange (ETDEWEB)

    Xu, Zhenjun [Architectural Engineering College, Qingdao Agricultural University, 266109 (China); Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao 266101 (China); Tianjin University, Tianjin, 300072 (China); Wu, Huaizhi; Wu, Meiling [Qingdao Institute of Bioenergy and Bioprocess Technology, Chinese Academy of Sciences, Qingdao 266101 (China); Tianjin University, Tianjin, 300072 (China)

    2010-12-15

    Biogas engine-driven heat pump air conditioner is a new-style system which includes biogas engine-driven heat pump, primary heat exchanger, second heat exchanger, sprayed room and fans, pumps, etc. In summertime, the air can be reheated by the waste heat water from the biogas engine in the system, while the air can be reheated and humidified by the waste heat water in winter. Reducing or displacing electrical heating requirements can achieve the great opportunity for significant energy savings. This paper, therefore, aims to improve the energy performance of the AC system by using the waste heat from the biogas engine. The mathematic model was used to research the BHPAC. Explicitly, we investigated the influence of various factors including the outdoor air temperature and humidity in summer and winter. Results show that the biogas engine-driven heat pump air conditioner can save more energy than the electrical power heat pump. In summer, the minimum for percentage of primary energy saving for BHPAC is over 25%. With the outdoor air dry-bulb temperature and the relative humidity rises, the saving energy percentage rises. In winter, the minimum for percentage of primary energy saving for BHPAC is 37%. The more the outdoor air relative humidity of the outdoor air decreases, the more the BHPAC saves energy. It is proved that the system which is a highly actively fully utilizing energy technology has good partial load characteristic and good effects of energy saving. (author)

  11. Hybrid Building Performance Simulation Models for Industrial Energy Efficiency Applications

    Directory of Open Access Journals (Sweden)

    Peter Smolek

    2018-06-01

    Full Text Available In the challenge of achieving environmental sustainability, industrial production plants, as large contributors to the overall energy demand of a country, are prime candidates for applying energy efficiency measures. A modelling approach using cubes is used to decompose a production facility into manageable modules. All aspects of the facility are considered, classified into the building, energy system, production and logistics. This approach leads to specific challenges for building performance simulations since all parts of the facility are highly interconnected. To meet this challenge, models for the building, thermal zones, energy converters and energy grids are presented and the interfaces to the production and logistics equipment are illustrated. The advantages and limitations of the chosen approach are discussed. In an example implementation, the feasibility of the approach and models is shown. Different scenarios are simulated to highlight the models and the results are compared.

  12. Measure Guideline: Energy-Efficient Window Performance and Selection

    Energy Technology Data Exchange (ETDEWEB)

    Carmody, J.; Haglund, K.

    2012-11-01

    This document provides guidelines for the selection of energy-efficient windows in new and existing residential construction in all US climate zones. It includes information on window products, their attributes and performance. It provides cost/benefit information on window energy savings as well as information on non-energy benefits such as thermal comfort and reduced HVAC demands. The document also provides information on energy impacts of design decisions such as window orientation, total glazing area and shading devices and conditions. Information on resources for proper window installation is included as well. This document is for builders, homeowners, designers and anyone making decisions about selecting energy efficient window. It is intended to complement other Building America information and efforts.

  13. Study on the energy performance of glazing surfaces

    Directory of Open Access Journals (Sweden)

    Ligia MOGA

    2014-12-01

    Full Text Available A proper thermal design of the building envelope represents an important factor for the energy economics. Glazing surfaces represent one of the important elements in the hygrothermal design activity of a building envelope. The window’s thermal performance has also a strong influence on the thermal performance of the opaque area of the wall. This fact imposed the research of the real interaction, of cooperation and of mutual influences of the characteristics between the two components of the wall of the building envelope, respectively the opaque and the glazing area. Optimal constructive details for the opaque and glazing area of the wall need to be properly designed in order to achieve the required thermal and energy performances imposed for new types of buildings, e.g. passive houses, zero energy buildings.

  14. [Effect of energy intake at breakfast on school performance].

    Science.gov (United States)

    Ma, G; Hu, X; Gao, S; Bai, D

    1999-09-30

    In order to examine the effect of energy intake at breakfast on school performance, 151 grade three school children from four classes of two schools were sampled for this study. Children were randomly assigned to breakfast A or B on any given day. They were provided with breakfast with either high or low energy content at school over a period of 5 successive days. The remained foods were collected and weighed. Performance tests including addition, multiplication, number checking, logic, creativity, physical endurance, visual-analogue scales were applied at the third or fourth period of courses in the morning on Tuesday through Friday during the experimental week. The teachers involved in the study were blind to the kind of treatment. No significant effect of energy intake at breakfast on these performance indicators was found in this study.

  15. Computational Analysis on Performance of Thermal Energy Storage (TES) Diffuser

    Science.gov (United States)

    Adib, M. A. H. M.; Adnan, F.; Ismail, A. R.; Kardigama, K.; Salaam, H. A.; Ahmad, Z.; Johari, N. H.; Anuar, Z.; Azmi, N. S. N.

    2012-09-01

    Application of thermal energy storage (TES) system reduces cost and energy consumption. The performance of the overall operation is affected by diffuser design. In this study, computational analysis is used to determine the thermocline thickness. Three dimensional simulations with different tank height-to-diameter ratio (HD), diffuser opening and the effect of difference number of diffuser holes are investigated. Medium HD tanks simulations with double ring octagonal diffuser show good thermocline behavior and clear distinction between warm and cold water. The result show, the best performance of thermocline thickness during 50% time charging occur in medium tank with height-to-diameter ratio of 4.0 and double ring octagonal diffuser with 48 holes (9mm opening ~ 60%) acceptable compared to diffuser with 6mm ~ 40% and 12mm ~ 80% opening. The conclusion is computational analysis method are very useful in the study on performance of thermal energy storage (TES).

  16. Computational Analysis on Performance of Thermal Energy Storage (TES) Diffuser

    International Nuclear Information System (INIS)

    Adib, M A H M; Ismail, A R; Kardigama, K; Salaam, H A; Ahmad, Z; Johari, N H; Anuar, Z; Azmi, N S N; Adnan, F

    2012-01-01

    Application of thermal energy storage (TES) system reduces cost and energy consumption. The performance of the overall operation is affected by diffuser design. In this study, computational analysis is used to determine the thermocline thickness. Three dimensional simulations with different tank height-to-diameter ratio (HD), diffuser opening and the effect of difference number of diffuser holes are investigated. Medium HD tanks simulations with double ring octagonal diffuser show good thermocline behavior and clear distinction between warm and cold water. The result show, the best performance of thermocline thickness during 50% time charging occur in medium tank with height-to-diameter ratio of 4.0 and double ring octagonal diffuser with 48 holes (9mm opening ∼ 60%) acceptable compared to diffuser with 6mm ∼ 40% and 12mm ∼ 80% opening. The conclusion is computational analysis method are very useful in the study on performance of thermal energy storage (TES).

  17. Energy Resolution Performance of the CMS Electromagnetic Calorimeter

    CERN Document Server

    Adzic, Petar; Almeida, Carlos; Almeida, Nuno; Anagnostou, Georgios; Anfreville, Marc; Anicin, Ivan; Antunovic, Zeljko; Auffray, Etiennette; Baccaro, Stefania; Baffioni, Stephanie; Barney, David; Barone, Luciano; Barrillon, Pierre; Bartoloni, Alessandro; Beauceron, Stephanie; Beaudette, Florian; Bell, Ken W; Benetta, Robert; Bercher, Michel; Berthon, Ursula; Betev, Botjo; Beuselinck, Raymond; Bhardwaj, Ashutosh; Biino, Cristina; Bimbot, Stephane; Blaha, Jan; Bloch, Philippe; Blyth, Simon; Bordalo, Paula; Bornheim, Adolf; Bourotte, Jean; Britton1, D; Brown, Robert M; Brunelière, Renaud; Busson, Philippe; Camporesi, Tiziano; Cartiglia, Nicolo; Cavallari, Francesca; Cerutti, Muriel; Chamont, David; Chang, Paoti; Chang, You-Hao; Charlot, Claude; Chatterji, Sudeep; Chen, E Augustine; Chipaux, Rémi; Choudhary, Brajesh C; Cockerill, David J A; Collard, Caroline; Combaret, Christophe; Cossutti, Fabio; Costantini, Silvia; Da Silva, J C; Dafinei, Ioan; Daskalakis, Georgios; Davatz, Giovanna; Debraine, Alain; Decotigny, David; De Min, Alberto; Deiters, Konrad; Dejardin, Marc; Della Negra, Rodolphe; Della Ricca, Giuseppe; Depasse, Pierre; Descamp, J; Dewhirst, Guy; Dhawan, Satish; Diemoz, Marcella; Dissertori, Günther; Dittmar, Michael; Djambazov, Lubomir; Dobrzynski, Ludwik; Drndarevic, Snezana; Dupanloup, Michel; Dzelalija, Mile; Ehlers, Jan; El-Mamouni, H; Peisert, Anna; Evangelou, Ioannis; Fabbro, Bernard; Faure, Jean-Louis; Fay, Jean; Ferri, Federico; Flower, Paul S; Franzoni, Giovanni; Funk, Wolfgang; Gaillac, Anne-Marie; Gargiulo, Corrado; Gascon-Shotkin, S; Geerebaert, Yannick; Gentit, François-Xavier; Ghezzi, Alessio; Gilly, Jean; Giolo-Nicollerat, Anne-Sylvie; Givernaud, Alain; Gninenko, Sergei; Go, Apollo; Godinovic, Nikola; Golubev, Nikolai; Golutvin, Igor; Gómez-Reino, Robert; Govoni, Pietro; Grahl1, J; Gras1, P; Greenhalgh, Justin; Guillaud, Jean-Paul; Haguenauer, Maurice; Hamel-de-Montechenault, G; Hansen, Magnus; Heath, Helen F; AHill, J; Hobson, Peter R; Holmes, Daniel; Holzner, André; Hou, George Wei-Shu; Ille, Bernard; Ingram, Quentin; Jain, Adarsh; Jarry, Patrick; Jauffret, C; Jha, Manoj; Karar, Akli; Kataria, Sushil Kumar; Katchanov, V A; Kennedy, Bruce W; Kloukinas, Kostas; Kokkas, Panagiotis; Korjik, M; Krasnikov, Nikolai; Krpic, Dragomir; Kyriakis, Aristotelis; Lebeau, Michel; Lecomte, Pierre; Lecoq, Paul; Lemaire, Marie-Claude; Lethuillier, Morgan; Lin, Willis; Lintern, A L; Lister, Alison; Litvin, V; Locci, Elizabeth; Lodge, Anthony B; Longo, Egidio; Loukas, Demetrios; Luckey, D; Lustermann, Werner; Lynch, Clare; MacKay, Catherine Kirsty; Malberti, Martina; Maletic, Dimitrije; Mandjavidze, Irakli; Manthos, Nikolaos; Markou, Athanasios; Mathez, Hervé; Mathieu, Antoine; Matveev, Viktor; Maurelli, Georges; Menichetti, Ezio; Meridiani, Paolo; Milenovic, Predrag; Milleret, Gérard; Miné, Philippe; Mur, Michel; Musienko, Yuri; Nardulli, Alessandro; Nash, Jordan; Neal, Homer; Nédélec, Patrick; Negri, Pietro; Nessi-Tedaldi, Francesca; Newman26, H B; Nikitenko, Alexander; Obertino, Maria Margherita; Ofierzynski, Radoslaw Adrian; Organtini, Giovanni; Paganini, Pascal; Paganoni, Marco; Papadopoulos, Ioannis; Paramatti, Riccardo; Pastrone, Nadia; Pauss, Felicitas; Poilleux, Patrick; Puljak, Ivica; Pullia, Antonino; Puzovic, Jovan; Ragazzi, Stefano; Ramos, Sergio; Rahatlou, Shahram; Rander, John; Ranjan, Kirti; Ravat, Olivier; Raymond, M; Razis, Panos A; Redaelli, Nicola; Renker, Dieter; Reucroft, Steve; Reymond, Jean-Marc; Reynaud, Michel; Reynaud, Serge; Romanteau, Thierry; Rondeaux, Françoise; Rosowsky, André; Rovelli, Chiara; Rumerio, Paolo; Rusack, Roger; Rusakov, Sergey V; Ryan, Matthew John; Rykaczewski, Hans; Sakhelashvili, Tariel; Salerno, Roberto; Santos, Marcelino; Seez, Christopher; Semeniouk, Igor; Sharif, Omar; Sharp, Peter; Shepherd-Themistocleous, Claire; Shevchenko, Sergey; Shivpuri, Ram Krishen; Sidiropoulos, Georgios; Sillou, Daniel; Singovsky, Alexander; Sirois, Yves; Sirunyan, Albert M; Smith, Brian; Smith, Vincent J; Sproston, Martin; Suter, Henry; Swain, John; Tabarelli de Fatis, Tommaso; Takahashi, Maiko; Tapper, Robert J; Tcheremoukhine, Alexandre; Teixeira, Isabel; Teixeira, Joao Paulo; Teller, Olivier; Timlin, Claire; ATriantis, F; Troshin, Sergey; Tyurin, Nikolay; Ueno, Koji; Uzunian, Andrey; Varela, Joao; Vaz-Cardoso, N; Verrecchia, Patrice; Vichoudis, Paschalis; Vigano, S; Viertel, Gert; Virdee, Tejinder; Vlassov, E; Wang, Minzu; Weinstein, Alan; Williams, Jennifer C; Yaselli, Ignacio; Zabi, Alexandre; Zamiatin, Nikolai; Zelepoukine, Serguei; Zeller, Michael E; Zhang, Lin; Zhang, Yawei; Zhu, Kejun; Zhu, Ren-Yuan

    2006-01-01

    The energy resolution performance of the CMS lead tungstate crystal electromagnetic calorimeter is presented. Measurements were made with an electron beam using a fully equipped supermodule of the calorimeter barrel. Results are given both for electrons incident on the centre of crystals and for electrons distributed uniformly over the calorimeter surface. The electron energy is reconstructed in matrices of 3 times 3 or 5 times 5 crystals centred on the crystal containing the maximum energy. Corrections for variations in the shower containment are applied in the case of uniform incidence. The resolution measured is consistent with the design goals.

  18. Check your school's energy performance

    Energy Technology Data Exchange (ETDEWEB)

    Jensen, Ole Michael [Danish Building Research Inst., Aalborg Univ. (Denmark)

    2007-07-01

    This paper presents the design of a poster presentation of a web tool for benchmarking schools. The poster will show how benchmarking makes it possible to compare the energy consumption of schools on the basis of the schools' age, type and location. In this way, the tool will draw attention to poor and good energy performance of the buildings, and in addition make key actors aware of energy-saving measures and if possible, low energy behaviour.A prototype version based on The Danish Energy Certificate Scheme introduced in 1997 is now available. This however, will be revised as soon as possible to adopt also schools labelled in agreement with a new Danish certification scheme, which is in accordance with The European Energy Performance Building Directive (EPBD). When entering the tool, the user is required to select a specific school and this school will be used for benchmarking. After this, the benchmarking can be designed at will. Heat, electricity, as well as the water consumption of the school can be objects for benchmarking. Moreover, the user can opt for several units of measurement such as kWh of heat per square meter per year, or cubic meters of water per pupil per day. The criteria for the selection of schools relevant for comparison can also be decided. Among these criteria are period of construction, number of storeys and geographical location. Finally, the tool enables the user to visualise the consequences for the school of different combinations of energy-saving measures, such as using low-energy windows and low-energy lighting.The tool is intended for energy officials, school caretakers, head teachers, teachers and even pupils. The development of the tool was financially subsidised via public service obligations. The administration and maintenance of the tool will for the next years be in the charge of the Danish Building Research Inst.

  19. Performance-based potential for residential energy efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Performance-based potential for residential energy efficiency

    2013-01-15

    Energy performance contracts (EPCs) have proven an effective mechanism for increasing energy efficiency in nearly all sectors of the economy since their introduction nearly 30 years ago. In the modern form, activities undertaken as part of an EPC are scoped and implemented by experts with specialized technical knowledge, financed by commercial lenders, and enable a facility owner to limit risk and investment of time and resources while receiving the rewards of improved energy performance. This report provides a review of the experiences of the US with EPCs and discusses the possibilities for the residential sector to utilize EPCs. Notably absent from the EPC market is the residential segment. Historically, research has shown that the residential sector varies in several key ways from markets segments where EPCs have proven successful, including: high degree of heterogeneity of energy use characteristics among and within households, comparatively small quantity of energy consumed per residence, limited access to information about energy consumption and savings potential, and market inefficiencies that constrain the value of efficiency measures. However, the combination of recent technological advances in automated metering infrastructure, flexible financing options, and the expansion of competitive wholesale electricity markets to include energy efficiency as a biddable supply-side resource present an opportunity for EPC-like efforts to successfully engage the residential sector, albeit following a different model than has been used in EPCs traditionally.(Author)

  20. Cost-optimal levels for energy performance requirements

    DEFF Research Database (Denmark)

    Thomsen, Kirsten Engelund; Aggerholm, Søren; Kluttig-Erhorn, Heike

    2011-01-01

    The CA conducted a study on experiences and challenges for setting cost optimal levels for energy performance requirements. The results were used as input by the EU Commission in their work of establishing the Regulation on a comparative methodology framework for calculating cost optimal levels...... of minimum energy performance requirements. In addition to the summary report released in August 2011, the full detailed report on this study is now also made available, just as the EC is about to publish its proposed Regulation for MS to apply in their process to update national building requirements....

  1. Energy upgrades as financial or strategic investment? Energy Star property owners and managers improving building energy performance

    International Nuclear Information System (INIS)

    Gliedt, Travis; Hoicka, Christina E.

    2015-01-01

    Highlights: • Energy Star property owners/managers view energy as strategic or financial investments. • Energy performance improvements and motivations differ by property type. • Energy projects are most often funded by internal cash reserves. • Motivations and funding sources differ by type of energy project. • Environmental sustainability is an important criterion in many energy projects. - Abstract: Due to its significant carbon footprint and cost-effectiveness for upgrades, the commercial property sector is important for climate change mitigation. Although barriers to energy system changes, such as funding, financing and information, are well recognized, Energy Star property owners and managers are successfully overcoming these barriers and instigating energy efficiency upgrades, renewable energy installations, and behavior and management programs. To examine the decision-making process that leads to energy performance improvements, a national survey of property owners and management organizations of buildings that earned an Energy Star score of 75 or higher was conducted. The extent to which energy upgrades were considered strategic investments motivated by environmental sustainability or corporate social responsibility, or financial investments motivated by payback period or return-on-investment criteria, was contingent upon the property type and type of energy project. Environmental sustainability was found to be an important motivation for energy projects in office spaces in general, but in the case of smaller office spaces was often combined with motivations for corporate social responsibility. Energy projects on education properties were motivated by financial investment. Building envelope and mechanical efficiency upgrades were considered financial investments, while renewable energy, green roofs, and water conservation technologies were considered environmental sustainability initiatives

  2. Creating high performance buildings: Lower energy, better comfort

    International Nuclear Information System (INIS)

    Brager, Gail; Arens, Edward

    2015-01-01

    Buildings play a critical role in the challenge of mitigating and adapting to climate change. It is estimated that buildings contribute 39% of the total U.S. greenhouse gas (GHG) emissions [1] primarily due to their operational energy use, and about 80% of this building energy use is for heating, cooling, ventilating, and lighting. An important premise of this paper is about the connection between energy and comfort. They are inseparable when one talks about high performance buildings. Worldwide data suggests that we are significantly overcooling buildings in the summer, resulting in increased energy use and problems with thermal comfort. In contrast, in naturally ventilated buildings without mechanical cooling, people are comfortable in much warmer temperatures due to shifting expectations and preferences as a result of occupants having a greater degree of personal control over their thermal environment; they have also become more accustomed to variable conditions that closely reflect the natural rhythms of outdoor climate patterns. This has resulted in an adaptive comfort zone that offers significant potential for encouraging naturally ventilated buildings to improve both energy use and comfort. Research on other forms for providing individualized control through low-energy personal comfort systems (desktop fans, foot warmed, and heated and cooled chairs) have also demonstrated enormous potential for improving both energy and comfort performance. Studies have demonstrated high levels of comfort with these systems while ambient temperatures ranged from 64–84°F. Energy and indoor environmental quality are inextricably linked, and must both be important goals of a high performance building

  3. Compressed Air Energy Storage System Control and Performance Assessment Using Energy Harvested Index

    Directory of Open Access Journals (Sweden)

    Hanif SedighNejad

    2014-01-01

    Full Text Available In this paper a new concept for control and performance assessment of compressed air energy storage (CAES systems in a hybrid energy system is introduced. The proposed criterion, based on the concept of energy harvest index (HEI, measures the capability of a storage system to capture renewable energy. The overall efficiency of the CAES system and optimum control and design from the technical and economic point of view is presented. A possible application of this idea is an isolated community with significant wind energy resource. A case study reveals the usefulness of the proposed criterion in design, control and implementation of a small CAES system in a hybrid power system (HPM for an isolated community. Energy harvested index and its effectiveness in increasing the wind penetration rate in the total energy production is discussed.

  4. Freedom of contract, mandatory and non-mandatory law in European contract law

    OpenAIRE

    Storme, M.

    2008-01-01

    Abstract: The purpose of this article is to reflect on the position and function of common European rules in respect of limitations to freedom of contract, and more specifically on the role of mandatory and non-mandatory rules in general. After dealing with this more generally in the first part, the article addresses in its second part the different techniques restricting freedom of contract that we find in the Principles of European Contract Law,(1) the acquis communautaire of the law of the...

  5. Long-term energy planning with uncertain environmental performance metrics

    International Nuclear Information System (INIS)

    Parkinson, Simon C.; Djilali, Ned

    2015-01-01

    Highlights: • Environmental performance uncertainty considered in a long-term energy planning model. • Application to electricity generation planning in British Columbia. • Interactions with climate change mitigation and adaptation strategy are assessed. • Performance risk-hedging impacts the technology investment strategy. • Sensitivity of results to model formulation is discussed. - Abstract: Environmental performance (EP) uncertainties span a number of energy technology options, and pose planning risk when the energy system is subject to environmental constraints. This paper presents two approaches to integrating EP uncertainty into the long-term energy planning framework. The methodologies consider stochastic EP metrics across multiple energy technology options, and produce a development strategy that hedges against the risk of exceeding environmental targets. Both methods are compared within a case study of emission-constrained electricity generation planning in British Columbia, Canada. The analysis provides important insight into model formulation and the interactions with concurrent environmental policy uncertainties. EP risk is found to be particularly important in situations where environmental constraints become increasingly stringent. Model results indicate allocation of a modest risk premium in these situations can provide valuable hedging against EP risk

  6. Assessing District Energy Systems Performance Integrated with Multiple Thermal Energy Storages

    Science.gov (United States)

    Rezaie, Behnaz

    The goal of this study is to examine various energy resources in district energy (DE) systems and then DE system performance development by means of multiple thermal energy storages (TES) application. This study sheds light on areas not yet investigated precisely in detail. Throughout the research, major components of the heat plant, energy suppliers of the DE systems, and TES characteristics are separately examined; integration of various configurations of the multiple TESs in the DE system is then analysed. In the first part of the study, various sources of energy are compared, in a consistent manner, financially and environmentally. The TES performance is then assessed from various aspects. Then, TES(s) and DE systems with several sources of energy are integrated, and are investigated as a heat process centre. The most efficient configurations of the multiple TESs integrated with the DE system are investigated. Some of the findings of this study are applied on an actual DE system. The outcomes of this study provide insight for researchers and engineers who work in this field, as well as policy makers and project managers who are decision-makers. The accomplishments of the study are original developments TESs and DE systems. As an original development the Enviro-Economic Function, to balance the economic and environmental aspects of energy resources technologies in DE systems, is developed; various configurations of multiple TESs, including series, parallel, and general grid, are developed. The developed related functions are discharge temperature and energy of the TES, and energy and exergy efficiencies of the TES. The TES charging and discharging behavior of TES instantaneously is also investigated to obtain the charging temperature, the maximum charging temperature, the charging energy flow, maximum heat flow capacity, the discharging temperature, the minimum charging temperature, the discharging energy flow, the maximum heat flow capacity, and performance

  7. Performance characteristics of aerodynamically optimum turbines for wind energy generators

    Science.gov (United States)

    Rohrbach, C.; Worobel, R.

    1975-01-01

    This paper presents a brief discussion of the aerodynamic methodology for wind energy generator turbines, an approach to the design of aerodynamically optimum wind turbines covering a broad range of design parameters, some insight on the effect on performance of nonoptimum blade shapes which may represent lower fabrication costs, the annual wind turbine energy for a family of optimum wind turbines, and areas of needed research. On the basis of the investigation, it is concluded that optimum wind turbines show high performance over a wide range of design velocity ratios; that structural requirements impose constraints on blade geometry; that variable pitch wind turbines provide excellent power regulation and that annual energy output is insensitive to design rpm and solidity of optimum wind turbines.

  8. Performance evaluation of various cryogenic energy storage systems

    International Nuclear Information System (INIS)

    Abdo, Rodrigo F.; Pedro, Hugo T.C.; Koury, Ricardo N.N.; Machado, Luiz; Coimbra, Carlos F.M.; Porto, Matheus P.

    2015-01-01

    This work compares various CES (cryogenic energy storage) systems as possible candidates to store energy from renewable sources. Mitigating solar and wind power variability and its direct effect on local grid stability are already a substantial technological bottleneck for increasing market penetration of these technologies. In this context, CES systems represent low-cost solutions for variability that can be used to set critical power ramp rates. We investigate the different thermodynamic and engineering constraints that affect the design of CES systems, presenting theoretical simulations, indicating that optimization is also needed to improve the cryogenic plant performance. - Highlights: • We assessed the performance of cryogenic energy storage systems. • We re-evaluated the Linde–Hampson cycle proposed by Chen. • We proposed the Claude and Collins cycles as alternatives for the Linde–Hampson cycle. • We concluded that Claude cycle is the best alternative for the simulated conditions.

  9. DAYLIGHTING AND ENERGY PERFORMANCE OF POST MILLENIUM CONDOMINIUMS IN SINGAPORE

    Directory of Open Access Journals (Sweden)

    Uma Maheswaran

    2007-03-01

    habitable spaces in their residence. This paper is an attempt to discuss a few examples of condominiums around the western part of Singapore as a means of discussing the emerging design trends as well as to discuss the performance aspects of the design solutions in terms of day lighting and energy consumption.

  10. Energy and Exergy Performance of three FPSO Operational Modes

    DEFF Research Database (Denmark)

    Sánchez, Yamid Alberto Carranza; Junior, Silvio de Oliveira; da Silva, Julio Augusto Mendes

    2015-01-01

    by the FPSO operator. Energy and exergy criteria have been applied to evaluate and compare the performance of components and systems of the three operational modes of the FPSO. The processing and utilities plants have been modeled and simulated by using Aspen HYSYS®. Results indicate that higher oil content...

  11. Performance of the Low-energy House in Sisimiut

    DEFF Research Database (Denmark)

    Rode, Carsten; Kragh, Jesper; Borchersen, Egil

    2009-01-01

    A low-energy house was built in Sisimiut, Greenland in 2004-05 and since its inauguration in April 2005, its performance and operation have been object of study for researchers and students. The house is characterised by a highly insulated building envelope, advanced windows and a ventilation sys...

  12. Experimental study on energy performance of clean air heat pump

    DEFF Research Database (Denmark)

    Fang, Lei; Nie, Jinzhe; Olesen, Bjarne W.

    2014-01-01

    An innovative clean air heat pump (CAHP) was designed and developed based on the air purification capacity of regenerative silica gel rotor. The clean air heat pump integrated air purification, dehumidification and cooling in one unit. A prototype of the clean air heat pump was developed...... to investigate its energy performance. Energy consumption of the prototype of CAHP was measured in laboratory at different climate conditions including mild-cold, mildhot and extremely hot and humid climates. The energy saving potential of the clean air heat pump compared to a conventional ventilation and air......-conditioning system was calculated. The experimental results showed that the clean air heat pump saved substantial amount of energy compared to the conventional system. For example, the CAHP can save up to 59% of electricity in Copenhagen, up to 40% of electricity in Milan and up to 30% of electricity in Colombo...

  13. Performance of Space Heating in a Modern Energy System

    DEFF Research Database (Denmark)

    Elmegaard, Brian

    2011-01-01

    In the paper we study the performance of a number of heat supply technologies. The background of the study is the changes in the Danish energy systems over the last three decades which have caused integration of large shares of combined heat and power (CHP), renewable fuels and wind power....... These changes mean that there is a significant integration of electricity and heat supply in the system and that several technologies may be beneficial. In particular, heat pumps are under consideration and are often considered to be renewable energy. We study how to distribute fuel and emissions to the heat...... supply. We find that heat supply is low-efficient seen from an exergy viewpoint, between 1% and 26% utilization. As exergy is a quantification of primary energy, we conclude that far better utilization of primary energy is possible. We also find that combined heat and power and domestic heat pumps...

  14. Building Performance Simulation tools for planning of energy efficiency retrofits

    DEFF Research Database (Denmark)

    Mondrup, Thomas Fænø; Karlshøj, Jan; Vestergaard, Flemming

    2014-01-01

    Designing energy efficiency retrofits for existing buildings will bring environmental, economic, social, and health benefits. However, selecting specific retrofit strategies is complex and requires careful planning. In this study, we describe a methodology for adopting Building Performance...... to energy efficiency retrofits in social housing. To generate energy savings, we focus on optimizing the building envelope. We evaluate alternative building envelope actions using procedural solar radiation and daylight simulations. In addition, we identify the digital information flow and the information...... Simulation (BPS) tools as energy and environmentally conscious decision-making aids. The methodology has been developed to screen buildings for potential improvements and to support the development of retrofit strategies. We present a case study of a Danish renovation project, implementing BPS approaches...

  15. 76 FR 64082 - Mandatory Reliability Standards for the Bulk-Power System; Notice of Staff Meeting

    Science.gov (United States)

    2011-10-17

    ... Reliability Standards for the Bulk-Power System; Notice of Staff Meeting Take notice that the Federal Energy... R1.3.10 of Commission-approved transmission planning Reliability Standard TPL-002- 0 (System... additional actions necessary to address the matter.\\3\\ \\1\\ Mandatory Reliability Standards for the Bulk-Power...

  16. Energy harvesting performance of piezoelectric ceramic and polymer nanowires.

    Science.gov (United States)

    Crossley, Sam; Kar-Narayan, Sohini

    2015-08-28

    Energy harvesting from ubiquitous ambient vibrations is attractive for autonomous small-power applications and thus considerable research is focused on piezoelectric materials as they permit direct inter-conversion of mechanical and electrical energy. Nanogenerators (NGs) based on piezoelectric nanowires are particularly attractive due to their sensitivity to small-scale vibrations and may possess superior mechanical-to-electrical conversion efficiency when compared to bulk or thin-film devices of the same material. However, candidate piezoelectric nanowires have hitherto been predominantly analyzed in terms of NG output (i.e. output voltage, output current and output power density). Surprisingly, the corresponding dynamical properties of the NG, including details of how the nanowires are mechanically driven and its impact on performance, have been largely neglected. Here we investigate all realizable NG driving contexts separately involving inertial displacement, applied stress T and applied strain S, highlighting the effect of driving mechanism and frequency on NG performance in each case. We argue that, in the majority of cases, the intrinsic high resonance frequencies of piezoelectric nanowires (∼tens of MHz) present no barrier to high levels of NG performance even at frequencies far below resonance (materials properties, for comparing piezoelectric NG performance under strain-driven and stress-driven conditions respectively. These figures of merit permit, for the first time, a general comparison of piezoelectric nanowires for NG applications that takes into account the nature of the mechanical excitation. We thus investigate the energy harvesting performance of prototypical piezoelectric ceramic and polymer nanowires. We find that even though ceramic and polymer nanowires have been found, in certain cases, to have similar energy conversion efficiencies, ceramics are more promising in strain-driven NGs while polymers are more promising for stress-driven NGs

  17. ENVIRONMENTAL SCENARIOS FOR MANDATORY BIO-FUEL BLENDING TARGETS: AN APPLICATION OF INTUITIVE LOGICS

    Directory of Open Access Journals (Sweden)

    Marco Antonio Conejero

    2010-09-01

    Full Text Available Scenarios depicting targets concerning mandatory bio-fuel blending are critical to the strategic planning of food and bio-energy production chains and their design is the purpose of this paper. Each scenario tells a story about how various elements might interact under given conditions. The method herein utilized is primarily based on Schoemaker´s (1995 and Schwartz´s (1991 earlier proposals. A six step framework is followed: i identify the focal issue; ii summarize current mandatory blending targets; iii identify the driving forces as of a macro-environmental analysis; iv validate driving forces with specialists; v rank such key forces by importance before uncertainties, building a correlation matrix; vi design the scenarios. Finally, three alternative scenarios, relative to the adoption on behalf of countries, by the year 2020, of mandatory bio-fuel blending targets, are proposed which might guide these countries’ decision makers when planning production systems.

  18. Energy-Performance as a driver for optimal production planning

    International Nuclear Information System (INIS)

    Salahi, Niloofar; Jafari, Mohsen A.

    2016-01-01

    Highlights: • A 2-dimensional Energy-Performance measure is proposed for energy aware production. • This is a novel approach integrates energy efficiency with production requirements. • This approach simultaneously incorporates machine and process related specifications. • The problem is solved as stochastic MILP with constraints addressing risk averseness. • The optimization is illustrated for 2 cases of single and serial machining operation. • Impact of various electricity pricing schemes on proposed production plan is analyzed. - Abstract: In this paper, we present energy-aware production planning using a two-dimensional “Energy-Performance” measure. With this measure, the production plan explicitly takes into account machine-level requirements, process control strategies, product types and demand patterns. The “Energy-Performance” measure is developed based on an existing concept, namely, “Specific Energy” at machine level. It is further expanded to an “Energy-Performance” profile for a production line. A production planning problem is formulated as a stochastic MILP with risk-averse constraints to account for manufacturer’s risk averseness. The objective is to attain an optimal production plan that minimizes the total loss distribution subject to system throughput targets, probabilistic risk constraints and constraints imposed by the underlying “Energy-Performance” pattern. Electricity price and demand per unit time are assumed to be stochastic. Conditional Value at Risk (CVaR) of loss distributions is used as the manufacturer’s risk measure. Both single-machine and production lines are studied for different profiles and electricity pricing schemes. It is shown that the shape of “Energy-Performance” profile can change optimal plans.

  19. MANDATORY TAKEOVER BIDS ON ROMANIAN CAPITAL MARKET

    Directory of Open Access Journals (Sweden)

    Cristian GHEORGHE

    2017-05-01

    Full Text Available The Romanian Capital Market Law (Law no 297/2004 lays down rules regarding public offers (to buy or sell of securities admitted to trading on a regulated market. Such offers are not unknown in the general framework of companies’ regulations, i.e. Company Law no 31/1990. Actually a public limited liability company (joint stock company can use a public subscriptions (offering shares for sale to raise the registered capital for incorporation of the company or to increase the company’s share capital already established. But all such operations are voluntary decisions. The founders or the shareholders of the company are those who decide to launch a public subscriptions. Capital Market Law comes with something new and at least peculiar at first sight: mandatory takeover bid, meaning a mandatory public offer made by an offeror to the holders of the securities of a company (offeree to acquire all or some of those securities. Can someone be forced to buy securities on the regulated market? The Capital Market Law responds affirmatively, but only if such takeover bid follows or has as its objective the acquisition of control of the offeree company in accordance with national law. The takeover bid remains under supervision and authorization of the national authority of the Capital Market (FSA – Financial Supervisory Authority.

  20. Energy performance of three Airtight Drywall Approach houses

    Energy Technology Data Exchange (ETDEWEB)

    Howell, D.G.; Mayhew, W.J.

    1987-03-01

    The objective of this study was to assess a new constructon technique, the Airtight Drywall Approach (ADA), as it was implemented in three test houses, and to compare the performance of these houses against three control houses typical of residential construction techniques in Alberta. The study focussed on four aspects of house performance integrity of the air barrier system, energy conservation. ventilation, and indoor air quality, and the development and demonstration of computer-based field monitoring techniques. Data were gathered through continuous computer-based measurements, regular site visits, manual measurements, homeowner interviews, and special site tests. The results of the air-leakage tests indicated that ADA is an effective method of reducing air infiltration in homes. The floor joist sealing technique used in the ADA houses was observed to deteriorate within a year of construction. It is no longer recommended. The monitoring results showed a significant reduction in energy consumption in the homes with energy conservation features. Measurements of air-borne contaminants indicated that the ADA test homes performed similar to other energy-efficient homes monitored across Canada and that pollutant levels were within accepted guidelines. 6 refs., 6 figs., 14 tabs.

  1. Methods of performing downhole operations using orbital vibrator energy sources

    Science.gov (United States)

    Cole, Jack H.; Weinberg, David M.; Wilson, Dennis R.

    2004-02-17

    Methods of performing down hole operations in a wellbore. A vibrational source is positioned within a tubular member such that an annulus is formed between the vibrational source and an interior surface of the tubular member. A fluid medium, such as high bulk modulus drilling mud, is disposed within the annulus. The vibrational source forms a fluid coupling with the tubular member through the fluid medium to transfer vibrational energy to the tubular member. The vibrational energy may be used, for example, to free a stuck tubular, consolidate a cement slurry and/or detect voids within a cement slurry prior to the curing thereof.

  2. Effect of wind energy system performance on optimal renewable energy model - an analysis

    International Nuclear Information System (INIS)

    Iniyan, S.; Jagadeesan, T.R.

    1998-01-01

    The Optimal Renewable Energy Model (OREM) has been developed to determine the optimum level of renewable energy sources utilisation in India for the year 2020-21. The model aims at minimising cost/efficiency ratio and determines the optimum allocation of different renewable energy sources for various end-uses. The extent of social acceptance level, potential limit, demand and reliability will decide the renewable energy distribution pattern and are hence used as constraints in the model. In this paper, the performance and reliability of wind energy system and its effects on OREM model has been analysed. The demonstration windfarm (4 MW) which is situated in Muppandal, a village in the southern part of India, has been selected for the study. The windfarm has 20 wind turbine machines of 200 KW capacity . The average technical availability, real availability and capacity factor have been analysed from 1991 to 1995 and they are found to be 94.1%, 76.4% and 25.5% respectively. The reliability factor of wind energy systems is found to be 0.5 at 10,000 hours. The OREM model is analysed considering the above said factors for wind energy system, solar energy system and biomass energy systems. The model selects wind energy for pumping end-use to an extent of 0.3153 x10 15 KJ. (Author)

  3. Analysis of Illinois Home Performance with ENERGY STAR® Measure Packages

    Energy Technology Data Exchange (ETDEWEB)

    Baker, J. [Partnership for Advanced Residential Retrofit (PARR), Chicago, IL (United States); Yee, S. [Partnership for Advanced Residential Retrofit (PARR), Chicago, IL (United States); Brand, L. [Partnership for Advanced Residential Retrofit (PARR), Chicago, IL (United States)

    2013-09-01

    Through the Chicagoland Single Family Housing Characterization and Retrofit Prioritization report, the Partnership for Advanced Residential Retrofit research team characterized 15 housing types in the Chicagoland region based on assessor data, utility billing history, and available data from prior energy efficiency programs. Within these 15 groups, a subset showed the greatest opportunity for energy savings based on BEopt Version 1.1 modeling of potential energy efficiency package options and the percent of the housing stock represented by each group. In this project, collected field data from a whole-home program in Illinois are utilized to compare marketplace-installed measures to the energy saving optimal packages previously developed for the 15 housing types. Housing type, conditions, energy efficiency measures installed, and retrofit cost information were collected from 19 homes that participated in the Illinois Home Performance with ENERGY STAR program in 2012, representing eight of the characterized housing groups. Two were selected for further case study analysis to provide an illustration of the differences between optimal and actually installed measures. Taken together, these homes are representative of 34.8% of the Chicagoland residential building stock. In one instance, actual installed measures closely matched optimal recommended measures.

  4. Performance of Radiant Heating Systems of Low-Energy Buildings

    Science.gov (United States)

    Sarbu, Ioan; Mirza, Matei; Crasmareanu, Emanuel

    2017-10-01

    After the introduction of plastic piping, the application of water-based radiant heating with pipes embedded in room surfaces (i.e., floors, walls, and ceilings), has significantly increased worldwide. Additionally, interest and growth in radiant heating and cooling systems have increased in recent years because they have been demonstrated to be energy efficient in comparison to all-air distribution systems. This paper briefly describes the heat distribution systems in buildings, focusing on the radiant panels (floor, wall, ceiling, and floor-ceiling). Main objective of this study is the performance investigation of different types of low-temperature heating systems with different methods. Additionally, a comparative analysis of the energy, environmental, and economic performances of floor, wall, ceiling, and floor-ceiling heating using numerical simulation with Transient Systems Simulation (TRNSYS) software is performed. This study showed that the floor-ceiling heating system has the best performance in terms of the lowest energy consumption, operation cost, CO2 emission, and the nominal boiler power. The comparison of the room operative air temperatures and the set-point operative air temperature indicates also that all radiant panel systems provide satisfactory results without significant deviations.

  5. Bike Desks in the Classroom: Energy Expenditure, Physical Health, Cognitive Performance, Brain Functioning, and Academic Performance.

    Science.gov (United States)

    Torbeyns, Tine; de Geus, Bas; Bailey, Stephen; Decroix, Lieselot; Van Cutsem, Jeroen; De Pauw, Kevin; Meeusen, Romain

    2017-06-01

    Physical activity is positively associated with physical health, cognitive performance, brain functioning and academic performance. The aim of this study is to investigate the influence of bike desks in the classroom on adolescents' energy expenditure, physical health, cognitive performance, brain functioning and academic performance. Forty-four adolescents were randomly assigned to control group (CG) or intervention group (IG). During 5 months, the IG used a bike desk for 4 class hours/week. Energy expenditure was measured during 6 consecutive days. Anthropometric parameters, aerobic fitness, academic performance, cognitive performance and brain functioning were assessed before (T0) and after (T1) the intervention. Energy expenditure of the IG was significantly higher during the class hours in which they used the bike desks relative to normal class hours. The CG had a significantly higher BMI at T1 relative to T0 while this was not significantly different for the IG. Aerobic fitness was significantly better in the IG at T1 relative to T0. No significant effects on academic performance cognitive performance and brain functioning were observed. As the implementation of bike desks in the classroom did not interfere with adolescents' academic performance, this can be seen as an effective means of reducing in-class sedentary time and improving adolescents' physical health.

  6. Calculation of the yearly energy performance of heating systems based on the European Building Energy Directive and related CEN Standards

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.; de Carli, Michele

    2011-01-01

    According to the Energy Performance of Buildings Directive (EPBD) all new European buildings (residential, commercial, industrial, etc.) must since 2006 have an energy declaration based on the calculated energy performance of the building, including heating, ventilating, cooling and lighting syst......–20% of the building energy demand. The additional loss depends on the type of heat emitter, type of control, pump and boiler. Keywords: Heating systems; CEN standards; Energy performance; Calculation methods......According to the Energy Performance of Buildings Directive (EPBD) all new European buildings (residential, commercial, industrial, etc.) must since 2006 have an energy declaration based on the calculated energy performance of the building, including heating, ventilating, cooling and lighting...... systems. This energy declaration must refer to the primary energy or CO2 emissions. The European Organization for Standardization (CEN) has prepared a series of standards for energy performance calculations for buildings and systems. This paper presents related standards for heating systems. The relevant...

  7. Energy extraction from atmospheric turbulence to improve flight vehicle performance

    Science.gov (United States)

    Patel, Chinmay Karsandas

    Small 'bird-sized' Unmanned Aerial Vehicles (UAVs) have now become practical due to technological advances in embedded electronics, miniature sensors and actuators, and propulsion systems. Birds are known to take advantage of wind currents to conserve energy and fly long distances without flapping their wings. This dissertation explores the possibility of improving the performance of small UAVs by extracting the energy available in atmospheric turbulence. An aircraft can gain energy from vertical gusts by increasing its lift in regions of updraft and reducing its lift in downdrafts - a concept that has been known for decades. Starting with a simple model of a glider flying through a sinusoidal gust, a parametric optimization approach is used to compute the minimum gust amplitude and optimal control input required for the glider to sustain flight without losing energy. For small UAVs using optimal control inputs, sinusoidal gusts with amplitude of 10--15% of the cruise speed are sufficient to keep the aircraft aloft. The method is then modified and extended to include random gusts that are representative of natural turbulence. A procedure to design optimal control laws for energy extraction from realistic gust profiles is developed using a Genetic Algorithm (GA). A feedback control law is designed to perform well over a variety of random gusts, and not be tailored for one particular gust. A small UAV flying in vertical turbulence is shown to obtain average energy savings of 35--40% with the use of a simple control law. The design procedure is also extended to determine optimal control laws for sinusoidal as well as turbulent lateral gusts. The theoretical work is complemented by experimental validation using a small autonomous UAV. The development of a lightweight autopilot and UAV platform is presented. Flight test results show that active control of the lift of an autonomous glider resulted in approximately 46% average energy savings compared to glides with fixed

  8. Caffeinated energy drinks improve volleyball performance in elite female players.

    Science.gov (United States)

    Pérez-López, Alberto; Salinero, Juan José; Abian-Vicen, Javier; Valadés, David; Lara, Beatriz; Hernandez, Cesar; Areces, Francisco; González, Cristina; Del Coso, Juan

    2015-04-01

    The objective of this study is to determine the effects of a caffeine-containing energy drink on female volleyball players' performance. Thirteen elite female volleyball players ingested 3 mg·kg of caffeine with an energy drink or the same drink without caffeine (placebo drink) in a double-blind and randomized study. Then, participants performed the following: standing spike, jumping spike, spike jump, blocking jump, squat jump, countermovement jump, manual dynamometry, and the agility t-test. A simulated volleyball game was played, videotaped, and notated afterward. In comparison to the placebo drink, the ingestion of the caffeinated energy drink increased the ball velocity in the standing spike (19.2 ± 2.1 vs 19.7 ± 1.9 m·s, P = 0.023) and in the jumping spike (17.9 ± 2.2 vs 18.8 ± 2.2 m·s, P = 0.038) and the jump height in the squat jump (28.1 ± 3.2 vs 29.4 ± 3.6 cm, P = 0.028), countermovement jump (32.0 ± 4.6 vs 33.1 ± 4.5 cm, P = 0.018), spike jump (43.3 ± 4.7 vs 44.4 ± 5.0 cm, P = 0.025), and block jump (35.2 ± 5.1 vs 36.1 ± 5.1 cm, P = 0.044). Furthermore, the caffeinated energy drink decreased the time needed to complete the agility t-test (11.1 ± 0.5 vs 10.9 ± 0.3 s, P = 0.036). During the game, the volleyball actions categorized as successful were more frequent with the caffeinated energy drink (34% ± 9% vs 45% ± 9%, P volleyball players. Increased physical performance led to improved accuracy during an actual volleyball match.

  9. Energy harvesting performance of piezoelectric ceramic and polymer nanowires

    International Nuclear Information System (INIS)

    Crossley, Sam; Kar-Narayan, Sohini

    2015-01-01

    Energy harvesting from ubiquitous ambient vibrations is attractive for autonomous small-power applications and thus considerable research is focused on piezoelectric materials as they permit direct inter-conversion of mechanical and electrical energy. Nanogenerators (NGs) based on piezoelectric nanowires are particularly attractive due to their sensitivity to small-scale vibrations and may possess superior mechanical-to-electrical conversion efficiency when compared to bulk or thin-film devices of the same material. However, candidate piezoelectric nanowires have hitherto been predominantly analyzed in terms of NG output (i.e. output voltage, output current and output power density). Surprisingly, the corresponding dynamical properties of the NG, including details of how the nanowires are mechanically driven and its impact on performance, have been largely neglected. Here we investigate all realizable NG driving contexts separately involving inertial displacement, applied stress T and applied strain S, highlighting the effect of driving mechanism and frequency on NG performance in each case. We argue that, in the majority of cases, the intrinsic high resonance frequencies of piezoelectric nanowires (∼tens of MHz) present no barrier to high levels of NG performance even at frequencies far below resonance (<1 kHz) typically characteristic of ambient vibrations. In this context, we introduce vibrational energy harvesting (VEH) coefficients η S and η T , based on intrinsic materials properties, for comparing piezoelectric NG performance under strain-driven and stress-driven conditions respectively. These figures of merit permit, for the first time, a general comparison of piezoelectric nanowires for NG applications that takes into account the nature of the mechanical excitation. We thus investigate the energy harvesting performance of prototypical piezoelectric ceramic and polymer nanowires. We find that even though ceramic and polymer nanowires have been found, in

  10. From Energy Audits to Home Performance: 30 Years of Articles in Home Energy Magazine

    Energy Technology Data Exchange (ETDEWEB)

    Meier, Alan

    2014-08-11

    Home Energy Magazine has been publishing articles about residential energy efficiency for 30 years. Its goal has been to disseminate technically reliable and neutral information to the practitioners, that is, professionals in the business of home energy efficiency. The articles, editorials, letters, and advertisements are a kind of window on the evolution of energy conservation technologies, policies, and organizations. Initially, the focus was on audits and simple retrofits, such as weatherstripping and insulation. Instrumentation was sparse sometimes limited to a ruler to measure depth of attic insulation and a blower door was exotic. CFLs were heavy, awkward bulbs which might, or might not, fit in a fixture. Saving air conditioning energy was not a priority. Solar energy was only for the most adventurous. Thirty years on, the technologies and business have moved beyond just insulating attics to the larger challenge of delivering home performance and achieving zero net energy. This shift reflects the success in reducing space heating energy and the need to create a profitable industry by providing more services. The leading edge of the residential energy services market is becoming much more sophisticated, offering both efficiency and solar systems. The challenge is to continue providing relevant and reliable information in a transformed industry and a revolutionized media landscape.

  11. Performance of two Vermont elementary school integrated energy conservation/solar energy retrofit projects

    Energy Technology Data Exchange (ETDEWEB)

    Hayes, J.W. (Marlboro College, VT); Converse, A.O.

    1980-01-01

    Two Vermont elementary school energy conservation/passive solar energy retrofit projects are described. Both masonry buildings were insulated with polystyrene on the east, north and west exterior walls. The south walls of each building were converted to Trombe walls, and, in addition, a portion of the south wall of one building was fitted with a solar greenhouse. The construction details, the predicted performance, and some actual results are reported here.

  12. White Paper: Unleashing Energy Efficiency Retrofits Through Energy Performance Contracts in China and the United States

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Price, Lynn [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Liu, Manzhi [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Meng, Lu [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Miao, Pei [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Dai, Fan [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Evans, Meredydd [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Yu, Sha [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Roshchanka, Volha [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Halverson, Mark [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2015-09-15

    Energy performance contracting (EPC) is a mechanism that uses private sector investment and expertise to deploy energy efficiency retrofits in buildings, industries, and other types of facilities. China and the United States both have large, growing EPC markets. This White Paper shares key insights on each market, including strengths and barriers inherent to these markets, compares the two markets, and sets forth options for enhancing EPC markets in each country. The White Paper concludes with recommendations structured around common goals of both countries.

  13. Energy Efficiency and Conservation Block Grant (EECBG) - Better Buildings Neighborhood Program at Greater Cincinnati Energy Alliance: Home Performance with Energy Star® and Better Buildings Performance

    Energy Technology Data Exchange (ETDEWEB)

    Holzhauser, Andy; Jones, Chris; Faust, Jeremy; Meyer, Chris; Van Divender, Lisa

    2013-12-30

    The Greater Cincinnati Energy Alliance (Energy Alliance) is a nonprofit economic development agency dedicated to helping Greater Cincinnati and Northern Kentucky communities reduce energy consumption. The Energy Alliance has launched programs to educate homeowners, commercial property owners, and nonprofit organizations about energy efficiency opportunities they can use to drive energy use reductions and financial savings, while extending significant focus to creating/retaining jobs through these programs. The mission of the Energy Alliance is based on the premise that investment in energy efficiency can lead to transformative economic development in a region. With support from seven municipalities, the Energy Alliance began operation in early 2010 and has been among the fastest growing nonprofit organizations in the Greater Cincinnati/Northern Kentucky area. The Energy Alliance offers two programs endorsed by the Department of Energy: the Home Performance with ENERGY STAR® Program for homeowners and the Better Buildings Performance Program for commercial entities. Both programs couple expert guidance, project management, and education in energy efficiency best practices with incentives and innovative energy efficiency financing to help building owners effectively invest in the energy efficiency, comfort, health, longevity, and environmental impact of their residential or commercial buildings. The Energy Alliance has raised over $23 million of public and private capital to build a robust market for energy efficiency investment. Of the $23 million, $17 million was a direct grant from the Department of Energy Better Buildings Neighborhood Program (BBNP). The organization’s investments in energy efficiency projects in the residential and commercial sector have led to well over $50 million in direct economic activity and created over 375,000 hours of labor created or retained. In addition, over 250 workers have been trained through the Building Performance Training

  14. Interim performance criteria for photovoltaic energy systems. [Glossary included

    Energy Technology Data Exchange (ETDEWEB)

    DeBlasio, R.; Forman, S.; Hogan, S.; Nuss, G.; Post, H.; Ross, R.; Schafft, H.

    1980-12-01

    This document is a response to the Photovoltaic Research, Development, and Demonstration Act of 1978 (P.L. 95-590) which required the generation of performance criteria for photovoltaic energy systems. Since the document is evolutionary and will be updated, the term interim is used. More than 50 experts in the photovoltaic field have contributed in the writing and review of the 179 performance criteria listed in this document. The performance criteria address characteristics of present-day photovoltaic systems that are of interest to manufacturers, government agencies, purchasers, and all others interested in various aspects of photovoltaic system performance and safety. The performance criteria apply to the system as a whole and to its possible subsystems: array, power conditioning, monitor and control, storage, cabling, and power distribution. They are further categorized according to the following performance attributes: electrical, thermal, mechanical/structural, safety, durability/reliability, installation/operation/maintenance, and building/site. Each criterion contains a statement of expected performance (nonprescriptive), a method of evaluation, and a commentary with further information or justification. Over 50 references for background information are also given. A glossary with definitions relevant to photovoltaic systems and a section on test methods are presented in the appendices. Twenty test methods are included to measure performance characteristics of the subsystem elements. These test methods and other parts of the document will be expanded or revised as future experience and needs dictate.

  15. Energy Performance of Hotel Buildings in Lijiang, China

    Directory of Open Access Journals (Sweden)

    Mingfang Tang

    2016-08-01

    Full Text Available The hotel industry in China has experienced rapid growth in the past ten years and made a considerable contribution to the global tourism economy. This paper focuses on the energy performance of hotel buildings in Lijiang, China. Hotel characteristics, daily operational data, and energy use data were collected by carrying out a survey of 24 hotels. The average annual energy use intensity (EUI of four-, three-, two-, and one-star rated hotels was 180.8 kWh/m2, 113.3 kWh/m2, 74.2 kWh/m2, and 70.2 kWh/m2, respectively. Electricity, as the dominant energy source, accounted for 81% of total energy consumption and was used in the operation of air conditioning, lighting, heating, etc. Pearson correlations between EUI showed that hotel star rating, number of guest rooms, room revenue, and number of workers gave a reasonably strong correlation. A regression-based benchmarking model was established to predict EUI, and a standardization process of EUI was illustrated by statistical analysis.

  16. ASPECTS REGARDING CORPORATE MANDATORY AND VOLUNTARY DISCLOSURE

    Directory of Open Access Journals (Sweden)

    Popa Adina

    2008-05-01

    Full Text Available The paper highlights theoretical aspects regarding corporate mandatory and voluntary disclosure. Since financial and business reporting are important information sources for different stakeholders, especially for publicly traded companies, the business reporting is increasingly oriented to the need of different users. In order to make rational investment decisions, users of corporate annual and interim reports require an extensive range of information. The increasing needs of the users persuade different international bodies and researchers to investigate the improvements that can be done in business reporting. The results of those studies usually were different reporting models. Because voluntary dimension of corporate disclosure involve the manifestation of free choice of the firm and its managers, we have considered as necessary to achieve a theoretical analysis of the main costs and profits of the voluntary disclosure policy.

  17. Solar Total Energy Project (STEP) Performance Analysis of High Temperature Energy Storage Subsystem

    Science.gov (United States)

    Moore, D. M.

    1984-01-01

    The 1982 milestones and lessons learned; performance in 1983; a typical day's operation; collector field performance and thermal losses; and formal testing are highlighted. An initial test that involves characterizing the high temperature storage (hts) subsystem is emphasized. The primary element is on 11,000 gallon storage tank that provides energy to the steam generator during transient solar conditions or extends operating time. Overnight, thermal losses were analyzed. The length of time the system is operated at various levels of cogeneration using stored energy is reviewed.

  18. Mandatory special or dedicated trains for radioactive materials shipments evidence shows they're not needed

    International Nuclear Information System (INIS)

    Goodman, L.S.; Garrison, R.F.; Harmon, L.H.

    1988-01-01

    The rejection of mandatory special or dedicated trains by all responsible Federal agencies for transportation of radioactive materials in shielded casks has a long history. Working with the railroads and the National Academy of Sciences, the ICC adopted standards for transporting radioactive materials in regular freight trains in the mid 1940's. The standards rested primarily on ensuring the integrity of the radioactive materials packaging. AEC, then NRC and DOT, followed the ICC lead, supplementing the licensing rules for casks with a series of performance or stress tests. At no time did these agencies require special trains or special routing for rail casks. Mandatory special trains have too many disadvantages without any proven safety benefit to be worth their high cost to the shipper. The ICC, in a series of litigated cases, found that given the strength of the casks, mandatory special trains were wasteful transportation and an unreasonable railroad practice

  19. Measuring improvement in energy efficiency of the US cement industry with the ENERGY STAR Energy Performance Indicator

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, G.; Zhang, G. [Department of Economics, Duke University, Box 90097, Durham, NC 27708 (United States)

    2013-02-15

    The lack of a system for benchmarking industrial plant energy efficiency represents a major obstacle to improving efficiency. While estimates are sometimes available for specific technologies, the efficiency of one plant versus another could only be captured by benchmarking the energy efficiency of the whole plant and not by looking at its components. This paper presents an approach used by ENERGY STAR to implement manufacturing plant energy benchmarking for the cement industry. Using plant-level data and statistical analysis, we control for factors that influence energy use that are not efficiency, per se. What remains is an estimate of the distribution of energy use that is not accounted for by these factors, i.e., intra-plant energy efficiency. By comparing two separate analyses conducted at different points in time, we can see how this distribution has changed. While aggregate data can be used to estimate an average rate of improvement in terms of total industry energy use and production, such an estimate would be misleading as it may give the impression that all plants have made the same improvements. The picture that emerges from our plant-level statistical analysis is more subtle; the most energy-intensive plants have closed or been completely replaced and poor performing plants have made efficiency gains, reducing the gap between themselves and the top performers, whom have changed only slightly. Our estimate is a 13 % change in total source energy, equivalent to an annual reduction of 5.4 billion/kg of energy-related carbon dioxide emissions.

  20. Institute for Sustained Performance, Energy, and Resilience (SuPER)

    Energy Technology Data Exchange (ETDEWEB)

    Jagode, Heike [Univ. of Tennessee, Knoxville, TN (United States); Bosilca, George [Univ. of Tennessee, Knoxville, TN (United States); Danalis, Anthony [Univ. of Tennessee, Knoxville, TN (United States); Dongarra, Jack [Univ. of Tennessee, Knoxville, TN (United States); Moore, Shirley [Univ. of Texas, El Paso, TX (United States)

    2016-11-30

    The University of Tennessee (UTK) and University of Texas at El Paso (UTEP) partnership supported the three main thrusts of the SUPER project---performance, energy, and resilience. The UTK-UTEP effort thus helped advance the main goal of SUPER, which was to ensure that DOE's computational scientists can successfully exploit the emerging generation of high performance computing (HPC) systems. This goal is being met by providing application scientists with strategies and tools to productively maximize performance, conserve energy, and attain resilience. The primary vehicle through which UTK provided performance measurement support to SUPER and the larger HPC community is the Performance Application Programming Interface (PAPI). PAPI is an ongoing project that provides a consistent interface and methodology for collecting hardware performance information from various hardware and software components, including most major CPUs, GPUs and accelerators, interconnects, I/O systems, and power interfaces, as well as virtual cloud environments. The PAPI software is widely used for performance modeling of scientific and engineering applications---for example, the HOMME (High Order Methods Modeling Environment) climate code, and the GAMESS and NWChem computational chemistry codes---on DOE supercomputers. PAPI is widely deployed as middleware for use by higher-level profiling, tracing, and sampling tools (e.g., CrayPat, HPCToolkit, Scalasca, Score-P, TAU, Vampir, PerfExpert), making it the de facto standard for hardware counter analysis. PAPI has established itself as fundamental software infrastructure in every application domain (spanning academia, government, and industry), where improving performance can be mission critical. Ultimately, as more application scientists migrate their applications to HPC platforms, they will benefit from the extended capabilities this grant brought to PAPI to analyze and optimize performance in these environments, whether they use PAPI

  1. The impact of roofing material on building energy performance

    Science.gov (United States)

    Badiee, Ali

    The last decade has seen an increase in the efficient use of energy sources such as water, electricity, and natural gas as well as a variety of roofing materials, in the heating and cooling of both residential and commercial infrastructure. Oil costs, coal and natural gas prices remain high and unstable. All of these instabilities and increased costs have resulted in higher heating and cooling costs, and engineers are making an effort to keep them under control by using energy efficient building materials. The building envelope (that which separates the indoor and outdoor environments of a building) plays a significant role in the rate of building energy consumption. An appropriate architectural design of a building envelope can considerably lower the energy consumption during hot summers and cold winters, resulting in reduced HVAC loads. Several building components (walls, roofs, fenestration, foundations, thermal insulation, external shading devices, thermal mass, etc.) make up this essential part of a building. However, thermal insulation of a building's rooftop is the most essential part of a building envelope in that it reduces the incoming "heat flux" (defined as the amount of heat transferred per unit area per unit time from or to a surface) (Sadineni et al., 2011). Moreover, more than 60% of heat transfer occurs through the roof regardless of weather, since a roof is often the building surface that receives the largest amount of solar radiation per square annually (Suman, and Srivastava, 2009). Hence, an argument can be made that the emphasis on building energy efficiency has influenced roofing manufacturing more than any other building envelope component. This research project will address roofing energy performance as the source of nearly 60% of the building heat transfer (Suman, and Srivastava, 2009). We will also rank different roofing materials in terms of their energy performance. Other parts of the building envelope such as walls, foundation

  2. Advanced Energy Retrofit Guide: Practical Ways to Improve Energy Performance, K-12 Schools (Book)

    Energy Technology Data Exchange (ETDEWEB)

    2013-12-01

    The U.S. Department of Energy developed the Advanced Energy Retrofit Guides (AERGs) to provide specific methodologies, information, and guidance to help energy managers and other stakeholders plan and execute energy efficiency improvements. Detailed technical discussion is fairly limited. Instead, we emphasize actionable information, practical methodologies, diverse case studies, and unbiased evaluations of the most promising retrofit energy efficiency measures for each building type. A series of AERGs is under development, addressing key segments of the commercial building stock. K-12 schools were selected as one of the highest priority building sectors, because schools affect the lives of most Americans. They also represent approximately 8% of the energy use and 10% of the floor area in commercial buildings nationwide. U.S. K-12 school districts spend more than $8 billion each year on energy - more than they spend on computers and textbooks combined. Most occupy older buildings that often have poor operational performance - more than 30% of schools were built before 1960. The average age of a school is about 42 years - which is nearly the expected serviceable lifespan of the building. K-12 schools offer unique opportunities for deep, cost-effective energy efficiency improvements, and this guide provides convenient and practical guidance for exploiting these opportunities in the context of public, private, and parochial schools.

  3. Energy performance certification as a signal of workplace quality

    International Nuclear Information System (INIS)

    Parkinson, Aidan; De Jong, Robert; Cooke, Alison; Guthrie, Peter

    2013-01-01

    Energy performance labelling and certification have been introduced widely to address market failures affecting the uptake of energy efficient technologies, by providing a signal to support decision making during contracting processes. The UK has recently introduced the Energy Performance Certificate (EPC) as a signal of building energy performance. The aims of this article are: to evaluate how valid EPC’s are signals of occupier satisfaction with office facilities; and to understand whether occupant attitudes towards environmental issues have affected commercial office rental values. This was achieved by surveying occupant satisfaction with their workplaces holistically using a novel multi-item rating scale which gathered 204 responses. Responses to this satisfaction scale were matched with the corresponding EPC and rental value of occupier’s workplaces. The satisfaction scale was found to be both a reliable and valid measure. The analysis found that EPC asset rating correlates significantly with occupant satisfaction with all facility attributes. Therefore, EPC ratings may be considered valid signals of overall facility satisfaction within the survey sample. Rental value was found to correlate significantly only with facility aesthetics. No evidence suggests rental value has been affected by occupants' perceptions towards the environmental impact of facilities. - Highlights: • A novel, internally consistent, and valid measure of office facility satisfaction. • EPC’s found to be a valid signal of overall facility satisfaction. • Historic rental value found to be an invalid measure of overall facility satisfaction. • No evidence suggests rental value has been affected by occupants' perceptions towards the environmental impact of facilities. • Occupants with stronger ties to landlords found to be more satisfied with office facilities

  4. Dynamic energy performance analysis: Case study for energy efficiency retrofits of hospital buildings

    International Nuclear Information System (INIS)

    Buonomano, Annamaria; Calise, Francesco; Ferruzzi, Gabriele; Palombo, Adolfo

    2014-01-01

    This paper investigates several actions for the energy refurbishment of some buildings of the University Hospital Federico II of Naples. The analysis focuses on a specific lot of 4 buildings, representative of the whole district hospital. For those structures, sustainable energy savings actions are investigated. They regard the installation of: i) roofs thermal insulation; ii) a substation climatic 3-way valve; iii) radiators thermostatic valves; iv) AHU (air handling unit) time-programmable regulation. This paper aims at presenting an investigation methodology, useful for designers and other stakeholders involved in hospital energy refurbishments, based on an integrated approach which combines dynamic energy performance simulations and experimental campaigns. In order to measure all the simulations' missing input parameters, a suitable experimental analysis, including measurements of temperature, humidity, flow rate and density of construction materials, is performed. A thermographic investigation is also performed for investigating the building envelope performance. This analysis showed that significant savings can be achieved especially by adopting radiators thermostatic valves and AHU regulations. Coherently, the installation of a 3-way valve in the substation does not determine significant additional savings when radiators thermostatic valves are already installed. For high-rise buildings, roofs insulation returns only marginal reductions of space heating and cooling demands. - Highlights: • Energy saving measures applied to the largest hospital of South Italy are analyzed. • A new approach combining dynamic simulations and measurements is implemented. • Thermography, temperature and flow measurements are performed. • High savings are achieved by adopting thermostatic valves and AHU control systems. • The simplest energy saving actions resulted to be the most profitable ones

  5. Randomized, controlled trial comparing synchronized intermittent mandatory ventilation and synchronized intermittent mandatory ventilation plus pressure support in preterm infants.

    Science.gov (United States)

    Reyes, Zenaida C; Claure, Nelson; Tauscher, Markus K; D'Ugard, Carmen; Vanbuskirk, Silvia; Bancalari, Eduardo

    2006-10-01

    Prolonged mechanical ventilation is associated with lung injury in preterm infants. In these infants, weaning from synchronized intermittent mandatory ventilation may be delayed by their inability to cope with increased respiratory loads. The addition of pressure support to synchronized intermittent mandatory ventilation can offset these loads and may facilitate weaning. The purpose of this work was to compare synchronized intermittent mandatory ventilation and synchronized intermittent mandatory ventilation plus pressure support in weaning from mechanical ventilation and the duration of supplemental oxygen dependency in preterm infants with respiratory failure. Preterm infants weighing 500 to 1000 g at birth who required mechanical ventilation during the first postnatal week were randomly assigned to synchronized intermittent mandatory ventilation or synchronized intermittent mandatory ventilation plus pressure support. In both groups, weaning followed a set protocol during the first 28 days. Outcomes were assessed during the first 28 days and until discharge or death. There were 107 infants enrolled (53 synchronized intermittent mandatory ventilation plus pressure support and 54 synchronized intermittent mandatory ventilation). Demographic and perinatal data, mortality, and morbidity did not differ between groups. During the first 28 days, infants in the synchronized intermittent mandatory ventilation plus pressure support group reached minimal ventilator settings and were extubated earlier than infants in the synchronized intermittent mandatory ventilation group. Total duration of mechanical ventilation, duration of oxygen dependency, and oxygen need at 36 weeks' postmenstrual age alone or combined with death did not differ between groups. However, infants in synchronized intermittent mandatory ventilation plus pressure support within the 700- to 1000-g birth weight strata had a shorter oxygen dependency. The results of this study suggest that the addition of

  6. Sensitivity analysis for the energy performance assessment of hybrid compressed air energy storage systems

    International Nuclear Information System (INIS)

    Briola, Stefano; Di Marco, Paolo; Gabbrielli, Roberto; Riccardi, Juri

    2017-01-01

    Highlights: •A sensitivity analysis and DOE of the complete hybrid CAES are carried out. •The influence of the storage site volume on performance indicators is negligible. •The performances increase with the decrease of the compressor outlet pressure. •The performances are correlated for each temperature increase in combustion chamber. •Hybridization of Huntorf implies a significant increase of its first law efficiency. -- Abstract: A detailed mathematical model was developed for the complete Hybrid Compressed Air Energy Storage (H-CAES) configuration with underground storage site and liquid thermal energy storage, operating with a sequence of processes (charging, holding and discharging with respective duration) in arbitrary order. A sensitivity analysis was carried out in order to calculate several performance indicators of the complete H-CAES configuration, in relation to the simultaneous change of several process parameters. The methodology “Design of Experiments” was applied to the results of the sensitivity analysis in order to calculate the main effects of each process parameter on each performance indicator. The influence of the storage site volume on each performance indicator is negligible. The reduction of the compressor group outlet pressure and of the turbine group power allows a more effective thermodynamic utilization both of the energy stored by the compressors and of the overall energy supplied to the plant. Furthermore, the former utilization is more effective by an increase of the gas temperature in the combustion chambers, whereas the latter utilization is worsened. Moreover, as case study, the existing diabatic CAES plant of Huntorf was modified by introducing a diathermic oil thermal storage. This plant is suitable to operate according to a partial hybrid configuration by the deactivation of the heat exchanger located upstream of the low pressure turbine. The thermodynamic utilization of the overall energy supplied to the plant

  7. Reducing Energy Use in Existing Homes by 30%: Learning From Home Performance with ENERGY STAR

    Energy Technology Data Exchange (ETDEWEB)

    Liaukus, C. [Building America Research Alliance (BARA), Kent, WA (United States)

    2014-12-01

    The improvement of existing homes in the United States can have a much greater impact on overall residential energy use than the construction of highly efficient new homes. There are over 130 million existing housing units in the U.S., while annually new construction represents less than two percent of the total supply (U.S. Census Bureau, 2013). Therefore, the existing housing stock presents a clear opportunity and responsibility for Building America (BA) to guide the remodeling and retrofit market toward higher performance existing homes. There are active programs designed to improve the energy performance of existing homes. Home Performance with ENERGY STAR (HPwES) is a market-rate program among them. BARA's research in this project verified that the New Jersey HPwES program is achieving savings in existing homes that meet or exceed BA's goal of 30%. Among the 17 HPwES projects with utility data included in this report, 15 have actual energy savings ranging from 24% to 46%. Further, two of the homes achieved that level of energy savings without the costly replacement of heating and cooling equipment, which indicates that less costly envelope packages could be offered to consumers unable to invest in more costly mechanical packages, potentially creating broader market impact.

  8. Is whistleblowing now mandatory? The impact of mandatory reporting law on trust relationships in health care.

    Science.gov (United States)

    Hewitt, Jayne

    2013-09-01

    Trust is vital for promoting positive health care relationships aimed at achieving positive patient outcomes. Patients, as well as the broader society, trust that health care practitioners who have been granted authority by the state to provide safe and beneficial health care are competent to do so. Recent instances where patients have been harmed as the result of treatment that fell below the accepted standard of competence have negatively impacted on trust. As the state has a responsibility to protect the public from this type of harm, legislation that mandates reporting of certain instances where the behaviour of health care professionals has fallen below the acceptable standard has been introduced. While this may have been designed to restore public trust, this article argues that it has the potential to diminish trust on the basis that mandatory reporting may be equivalent to mandatory whistleblowing.

  9. Performance of renewable energy technologies in the energy-environmental-economic continuum

    International Nuclear Information System (INIS)

    Guthrie, B.M.; Birkenheier, T.L.

    1993-01-01

    Projected cost-performance data are used to calculate the Canadian commercial potential of selected renewable energy technologies to the year 2010. Based on projected market penetration, the extent to which renewable energy can contribute to environmental initiatives is also examined. The potential for renewable energy to contribute to the Canadian electricity supply is limited neither by the state of the technology nor the extent of the resource available. Barriers to acceptance of renewables include high initial capital costs, intermittent nature of much of the energy supply, land requirements, onerous requirements for environmental assessments and licensing, and lack of government policies which consider the externalities involved in new energy supply. Environmental benefits which will drive the adoption of renewables in Canada include the sustainable nature of renewable resources, low environmental impacts, and suitability for integrated resource planning. In addition, the cost performance of renewable technologies is improving rapidly. Under base-case scenarios, at current buyback rates, only small hydro and biomass of the five renewable technologies examined has significant commercial potential in Canada. At buyback rates that reflect currently projected avoided costs plus an additional 2 cents per kWh as an environmental premium, all five renewable technologies except for photovoltaics have appreciable commercial potential achievable by 2010. The quantity of electrical energy displaced under this latter scenario is estimated at 49 TWh/y, or 7% of the projected total generation in Canada. 2 figs., 2 tabs

  10. [Why do we need mandatory communication courses for pre-registration house officers?

    DEFF Research Database (Denmark)

    Pedersen, B.D.; Faarvang, K.L.; Larsen, M.H.

    2008-01-01

    This study reports the rationale for the composition of a 3-day mandatory communication skills course for pre-registration house officers (PRHOs). In addition to communication skills, the course addresses aspects of competence related to professional performance within areas covered by the legal...

  11. Performance of passive solar and energy conserving houses in California

    Science.gov (United States)

    Mahajan, S.; Newcomb, C.; Shea, M.; Mort, D.

    1983-11-01

    This report provides a technical description of the methodology and the results of a two year effort to collect field data on the performance of passive solar and energy conserving houses in California. Sixty-three passive solar houses were visited and several hours were spent with the homeowner obtaining building details, management procedures, architectural plans, photographs, and at least a year of billing data. With this information thermal performance parameters were calculated for each of the houses. Eleven of the above sixty-three Class C sites (nine passive solar and two energy conserving houses) were instrumented and monitored using the SERI Class B methodology as a guideline. Continuous data were collected for one year using up to 18 different sensors to measure temperatures, electric power, insolation, and the status of fans, gas burners, and moveable insulation. In addition careful one time measurements were made to determine the loss coefficient, infiltration rate, and furnace efficiency. Analysis of this data giving comfort conditions maintained and energy uses for a complete heating and cooling season for each of the houses is presented.

  12. Thermal performance and heat transport in aquifer thermal energy storage

    Science.gov (United States)

    Sommer, W. T.; Doornenbal, P. J.; Drijver, B. C.; van Gaans, P. F. M.; Leusbrock, I.; Grotenhuis, J. T. C.; Rijnaarts, H. H. M.

    2014-01-01

    Aquifer thermal energy storage (ATES) is used for seasonal storage of large quantities of thermal energy. Due to the increasing demand for sustainable energy, the number of ATES systems has increased rapidly, which has raised questions on the effect of ATES systems on their surroundings as well as their thermal performance. Furthermore, the increasing density of systems generates concern regarding thermal interference between the wells of one system and between neighboring systems. An assessment is made of (1) the thermal storage performance, and (2) the heat transport around the wells of an existing ATES system in the Netherlands. Reconstruction of flow rates and injection and extraction temperatures from hourly logs of operational data from 2005 to 2012 show that the average thermal recovery is 82 % for cold storage and 68 % for heat storage. Subsurface heat transport is monitored using distributed temperature sensing. Although the measurements reveal unequal distribution of flow rate over different parts of the well screen and preferential flow due to aquifer heterogeneity, sufficient well spacing has avoided thermal interference. However, oversizing of well spacing may limit the number of systems that can be realized in an area and lower the potential of ATES.

  13. Improving the performance of jaggery making unit using solar energy

    Directory of Open Access Journals (Sweden)

    Lakshmi Pathi Jakkamputi

    2016-09-01

    Full Text Available The thermal performance of open earth pan furnace used conventionally for preparing jaggery (gur is very low. Dry bagasse is used as a fuel to produce heat in a combustion process in the open earth furnace. The energy loss due to inefficient combustion process, the energy loss through exhaust gases and other losses due to furnace wall, convection and radiation bring the thermal efficiency of open earth pan furnace to a low value. Certain quantity of energy produced in combustion process is used to sensibly heat the sugarcane juice to its evaporation temperature. Solar collectors can supply the sensible heat required to raise the sugarcane juice temperature up to its boiling point, thereby reducing the total quantity of heat required in preparing the jaggery. Solar drier can be used to supply hot air required for the combustion process to burn the bagasse in more efficient manner. This paper presents analytical calculations done to study the performance improvement of the jaggery making unit using solar collector and solar drier.

  14. EnergiTools. A methodology for performance monitoring and diagnosis

    International Nuclear Information System (INIS)

    Ancion, P.; Bastien, R.; Ringdahl, K.

    2000-01-01

    EnergiTools is a performance monitoring and diagnostic tool that combines the power of on-line process data acquisition with advanced diagnosis methodologies. Analytical models based on thermodynamic principles are combined with neural networks to validate sensor data and to estimate missing or faulty measurements. Advanced diagnostic technologies are then applied to point out potential faults and areas to be investigated further. The diagnosis methodologies are based on Bayesian belief networks. Expert knowledge is captured in the form of the fault-symptom relationships and includes historical information as the likelihood of faults and symptoms. The methodology produces the likelihood of component failure root causes using the expert knowledge base. EnergiTools is used at Ringhals nuclear power plants. It has led to the diagnosis of various performance issues. Three case studies based on this plant data and model are presented and illustrate the diagnosis support methodologies implemented in EnergiTools . In the first case, the analytical data qualification technique points out several faulty measurements. The application of a neural network for the estimation of the nuclear reactor power by interpreting several plant indicators is then illustrated. The use of the Bayesian belief networks is finally described. (author)

  15. Energy and Environmental Performance of Bioethanol from Different Lignocelluloses

    Directory of Open Access Journals (Sweden)

    Lin Luo

    2010-01-01

    Full Text Available Climate change and the wish to reduce the dependence on oil are the incentives for the development of alternative energy sources. The use of lignocellulosic biomass together with cellulosic processing technology provides opportunities to produce fuel ethanol with less competition with food and nature. Many studies on energy analysis and life cycle assessment of second-generation bioethanol have been conducted. However, due to the different methodology used and different system boundary definition, it is difficult to compare their results. To permit a direct comparison of fuel ethanol from different lignocelluloses in terms of energy use and environmental impact, seven studies conducted in our group were summarized in this paper, where the same technologies were used to convert biomass to ethanol, the same system boundaries were defined, and the same allocation procedures were followed. A complete set of environmental impacts ranging from global warming potential to toxicity aspects is used. The results provide an overview on the energy efficiency and environmental performance of using fuel ethanol derived from different feedstocks in comparison with gasoline.

  16. Simulation Study of the Energy Performance of Different Space Heating Methods in Plus-energy Housing

    DEFF Research Database (Denmark)

    Schøtt, Jacob; Andersen, Mads E.; Kazanci, Ongun Berk

    2016-01-01

    Due to a shortage of energy resources, the focus on indoor environment and energy use in buildings is increasing which sets higher standards for the performance of HVAC systems in buildings. The variety of available heating systems for both residential buildings and office buildings is therefore...... cases the heat source was a natural gas fired condensing boiler, and for the floor heating cases also an air-to-water heat pump was used to compare two heat sources. The systems were also compared in terms of auxiliary energy use for pumps and fans. The results show that the investigated floor heating...... from the low temperature heating potential since an increased floor covering requires higher average water temperatures in the floor loops and decreases the COP of the heat pump. The water-based heating systems required significantly less auxiliary energy input compared to the air-based heating system...

  17. Composite Materials for Thermal Energy Storage: Enhancing Performance through Microstructures

    Science.gov (United States)

    Ge, Zhiwei; Ye, Feng; Ding, Yulong

    2014-01-01

    Chemical incompatibility and low thermal conductivity issues of molten-salt-based thermal energy storage materials can be addressed by using microstructured composites. Using a eutectic mixture of lithium and sodium carbonates as molten salt, magnesium oxide as supporting material, and graphite as thermal conductivity enhancer, the microstructural development, chemical compatibility, thermal stability, thermal conductivity, and thermal energy storage performance of composite materials are investigated. The ceramic supporting material is essential for preventing salt leakage and hence provides a solution to the chemical incompatibility issue. The use of graphite gives a significant enhancement on the thermal conductivity of the composite. Analyses suggest that the experimentally observed microstructural development of the composite is associated with the wettability of the salt on the ceramic substrate and that on the thermal conduction enhancer. PMID:24591286

  18. Performance Analysis of a Flywheel Energy Storage System

    Directory of Open Access Journals (Sweden)

    K. Ghedamsi

    2008-06-01

    Full Text Available The flywheel energy storage systems (FESSs are suitable for improving the quality of the electric power delivered by the wind generators and to help these generators to contribute to the ancillary services. In this paper, a flywheel energy storage system associated to a grid connected variable speed wind generation (VSWG scheme using a doubly fed induction generator (DFIG is investigated. Therefore, the dynamic behavior of a wind generator, including models of the wind turbine (aerodynamic, DFIG, matrix converter, converter control (algorithm of VENTURINI and power control is studied. This paper investigates also, the control method of the FESS with a classical squirrel-cage induction machine associated to a VSWG using back-to-back AC/AC converter. Simulation results of the dynamic models of the wind generator are presented, for different operating points, to show the good performance of the proposed system.

  19. Composite materials for thermal energy storage: enhancing performance through microstructures.

    Science.gov (United States)

    Ge, Zhiwei; Ye, Feng; Ding, Yulong

    2014-05-01

    Chemical incompatibility and low thermal conductivity issues of molten-salt-based thermal energy storage materials can be addressed by using microstructured composites. Using a eutectic mixture of lithium and sodium carbonates as molten salt, magnesium oxide as supporting material, and graphite as thermal conductivity enhancer, the microstructural development, chemical compatibility, thermal stability, thermal conductivity, and thermal energy storage performance of composite materials are investigated. The ceramic supporting material is essential for preventing salt leakage and hence provides a solution to the chemical incompatibility issue. The use of graphite gives a significant enhancement on the thermal conductivity of the composite. Analyses suggest that the experimentally observed microstructural development of the composite is associated with the wettability of the salt on the ceramic substrate and that on the thermal conduction enhancer. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  20. Energy efficiency performance contracts in the school environment; Contrats de performance energetique dans le milieu scolaire

    Energy Technology Data Exchange (ETDEWEB)

    Drouin, J. [Quebec Ministere de l' Education, Ste-Foy, PQ (Canada)

    1999-12-01

    An overview of new regulations concerning the awarding of energy performance contracts by school boards in the province of Quebec is provided. The article deals with buildings belonging to boards of education that are wholly or primarily utilised for educational purposes. It provides an inventory of such buildings and statistical information about about energy consumption and energy-related costs of educational facilities during the school years 1996/1997 and 1997/1998. Regarding the new regulations, the principal change appears to be that school boards are required to award construction or building services contracts estimated to cost between $50,000 and $100,000 either by public requests for tenders, or by invitation; construction or building services contracts whose cost exceeds $100,000 must be awarded by public tender. In effect, to meet the energy efficiency criteria specified in the new regulations, school boards are obliged to call for bids on any project that contribute to the energy efficiency of school buildings whose cost is estimated to exceed $50,000. The objective of the new regulation is to encourage the consideration of energy efficiency standards by school boards, and by potential contractors. The regulations also prescribe the method of requesting bids and specifies the energy efficiency criteria bidders must meet in order to be eligible.

  1. The influence of the Energy Performance Certificate: The Dutch case

    International Nuclear Information System (INIS)

    Murphy, Lorraine

    2014-01-01

    All European Union Member States require an Energy Performance Certificate (EPC) when buildings are constructed, sold and rented. At its introduction the EPC was considered a pioneering instrument, one that would help overcome an information deficit hindering consumer interest in energy efficient dwellings. Now that the EPC has been implemented for several years it is possible to examine its impact. This research draws on data from ex-ante and ex-post assessments of the EPC in a number of countries and presents the results of a survey of Dutch private dwelling purchasers. This survey was based on two sample populations, one received an EPC during property transaction and another did not. Differences were sought between the two samples in a number of areas relating to the adoption of energy efficiency measures. Results show that many projections about the impact of the EPC have fallen short. The EPC was found to have a weak influence, especially pre-purchase. The potential of the EPC in driving energy efficiency improvement in the existing stock is doubted especially if it continues to act independent from a mix of instruments designed to tackle multiple barriers. It is argued that the energy saving potential of existing dwellings, applauded in climate change policy, will remain unexploited if it continues to be assessed subjectively by householders. - Highlights: • Results of a survey of EPC recipients and non-recipients are presented. • The influence of the EPC is analysed descriptively and statistically. • EPC is found to have a weak influence pre and post-purchase. • More sophisticated mechanisms are needed to enhance the EPC

  2. Performance of broiler chicken fed multicarbohydrases supplemented low energy diet

    Directory of Open Access Journals (Sweden)

    Kumar Govil

    2017-07-01

    Full Text Available Aim: Objective of this study was to investigate the effect of multicarbohydrases supplementation on performance of broilers fed low energy diet. Materials and Methods: A total of 75 days old chicks were selected and randomly divided into three treatments groups (T1, T2, and T3; each group contained 25 chicks distributed in five replicates of five chicks each. T1 group (positive control was offered control ration formulated as per Bureau of Indian Standards recommendations. In T2 group (negative control ration, metabolizable energy (ME was reduced by 100 kcal/kg diet. T3 group ration was same as that of T2 except that it was supplemented with multicarbohydrases (xylanase at 50 g/ton+mannanase at 50 g/ton+amylase at 40 g/ton. Feed intake and body weight of all experimental birds were recorded weekly. Metabolic trial was conducted for 3 days at the end of experiment to know the retention of nutrients. Results: Significant improvement (p<0.01 was observed in total weight gain, feed conversion efficiency, and performance index in broilers under supplementary group T3 as compared to T1 and T2 groups. Retention of crude protein and ether extract was significantly increased (p<0.05 in T3 group supplemented with multicarbohydrases as compared to other groups. Retention of dry matter, crude fiber, and nitrogen-free extract was comparable in all the three groups. Significantly highest dressed weight, eviscerated weight, and drawn weight (% of live body weight were observed in multicarbohydrases supplemented T3 group, however it was comparable in T1 and T2 groups. Conclusion: It was concluded that the supplementation of multicarbohydrases (xylanase at 50 g/ton+mannanase at 50 g/ton+amylase at 40 g/ton in low energy diet improved overall performance of broilers.

  3. High energy permanent magnets - Solutions to high performance devices

    International Nuclear Information System (INIS)

    Ma, B.M.; Willman, C.J.

    1986-01-01

    Neodymium iron boron magnets are a special class of magnets providing the highest level of performance with the least amount of material. Crucible Research Center produced the highest energy product magnet of 45 MGOe - a world record. Commercialization of this development has already taken place. Crucible Magnetics Division, located in Elizabethtown, Kentucky, is currently manufacturing and marketing six different grades of NdFeB magnets. Permanent magnets find application in motors, speakers, electron beam focusing devices for military and Star Wars. The new NdFeB magnets are of considerable interest for a wide range of applications

  4. 14 CFR 223.3 - Mandatory free transportation.

    Science.gov (United States)

    2010-01-01

    ... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Mandatory free transportation. 223.3 Section 223.3 Aeronautics and Space OFFICE OF THE SECRETARY, DEPARTMENT OF TRANSPORTATION (AVIATION PROCEEDINGS) ECONOMIC REGULATIONS FREE AND REDUCED-RATE TRANSPORTATION General Provisions § 223.3 Mandatory...

  5. 18 CFR 40.2 - Mandatory Reliability Standards.

    Science.gov (United States)

    2010-04-01

    ...-POWER SYSTEM § 40.2 Mandatory Reliability Standards. (a) Each applicable user, owner or operator of the Bulk-Power System must comply with Commission-approved Reliability Standards developed by the Electric... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Mandatory Reliability...

  6. 75 FR 48743 - Mandatory Reporting of Greenhouse Gases

    Science.gov (United States)

    2010-08-11

    ... Part II Environmental Protection Agency 40 CFR Part 98 Mandatory Reporting of Greenhouse Gases...-AQ33 Mandatory Reporting of Greenhouse Gases AGENCY: Environmental Protection Agency (EPA). ACTION... Greenhouse Gas Reporting Rule Hotline at telephone number: (877) 444-1188; or e-mail: [email protected] . To...

  7. 22 CFR 9.10 - Mandatory declassification review.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Mandatory declassification review. 9.10 Section 9.10 Foreign Relations DEPARTMENT OF STATE GENERAL SECURITY INFORMATION REGULATIONS § 9.10 Mandatory declassification review. All requests to the Department by a member of the public, a government employee, or an...

  8. 22 CFR 301.2 - Requests for mandatory declassification review.

    Science.gov (United States)

    2010-04-01

    ... 22 Foreign Relations 2 2010-04-01 2010-04-01 true Requests for mandatory declassification review. 301.2 Section 301.2 Foreign Relations PEACE CORPS PUBLIC ACCESS TO CLASSIFIED MATERIAL § 301.2 Requests for mandatory declassification review. (a) All information originally classified by the Peace...

  9. Policy Instruments to Improve Energy Performance of Existing Owner Occupied Dwellings

    Directory of Open Access Journals (Sweden)

    Lorraine Colette Murphy

    2016-11-01

    Full Text Available The aim of this thesis is to add knowledge to the role and impact of policy instruments in meeting energy performance ambition in the existing owner occupied housing stock. The focus was instruments available in the Netherlands in 2011 and 2012. These instruments represented the ‘on the ground’ efforts to meet climate change targets and many continue to do so today in the same or slightly altered forms. At international level there is a recognized need to keep global temperatures within the range of 1.5 - 2°C above pre-industrial levels (Carrington, 2016. At European level, the 2020 package contains a series of binding legislation to help the EU meet its more immediate climate and energy targets. 2020 targets include 20% reduction in greenhouse gas emission, 20% of EU energy obtained from renewable sources and 20% improvement in energy efficiency. 2020 targets for the Netherlands are a 20% reduction in greenhouse gas emissions and a 14% increase in energy generation from renewable sources (Vringer et al., 2014. A raft of policies has been produced over the last number of decades from international to local level to orientate action towards targets. At European level the Energy Performance of Buildings Directive (EPBD drives efforts at reducing energy among one of the biggest players, the building sector. By requiring a mandatory certificate at the point of sale and rent of buildings and making regulatory demands on existing buildings the EPBD upped the ante of what could be expected from the building sector, but especially the existing dwelling stock. National governments have already been tackling existing dwellings for decades propelled by the energy crisis and later by climate change policy. Information campaigns, subsidies, energy taxes, energy loans and tailored advice are among the instruments that have been available to homeowners to carry out works on their dwellings to reduce energy consumption. In recent years, the pace of efforts

  10. Advanced Energy Retrofit Guide (AERG): Practical Ways to Improve Energy Performance; Healthcare Facilities (Book)

    Energy Technology Data Exchange (ETDEWEB)

    Hendron, R.; Leach, M.; Bonnema, E.; Shekhar, D.; Pless, S.

    2013-09-01

    The Advanced Energy Retrofit Guide for Healthcare Facilities is part of a series of retrofit guides commissioned by the U.S. Department of Energy. By presenting general project planning guidance as well as detailed descriptions and financial payback metrics for the most important and relevant energy efficiency measures (EEMs), the guides provide a practical roadmap for effectively planning and implementing performance improvements in existing buildings. The Advanced Energy Retrofit Guides (AERGs) are intended to address key segments of the U.S. commercial building stock: retail stores, office buildings, K-12 schools, grocery stores, and healthcare facilities. The guides' general project planning considerations are applicable nationwide; the energy and cost savings estimates for recommended EEMs were developed based on energy simulations and cost estimates for an example hospital tailored to five distinct climate regions. These results can be extrapolated to other U.S. climate zones. Analysis is presented for individual EEMs, and for packages of recommended EEMs for two project types: existing building commissioning projects that apply low-cost and no-cost measures, and whole-building retrofits involving more capital-intensive measures.

  11. The SSG Wave Energy Converter: Performance, Status and Recent Developments

    Directory of Open Access Journals (Sweden)

    Mariano Buccino

    2012-01-01

    Full Text Available The Sea-wave Slot-cone Generator (SSG is a Wave Energy Converter based on the wave overtopping principle; it employs several reservoirs placed on top of each other, in which the energy of incoming waves is stored as potential energy. Then, the captured water runs through turbines for electricity production. The system works under a wide spectrum of different wave conditions, giving a high overall efficiency. It can be suitable for shoreline and breakwater applications and presents particular advantages, such as sharing structure costs, availability of grid connection and recirculation of water inside the harbor, as the outlet of the turbines is on the rear part of the system. Recently, plans for the SSG pilot installations are in progress at the Svaaheia site (Norway, the port of Hanstholm (Denmark and the port of Garibaldi (Oregon, USA. In the last-mentioned two projects, the Sea-wave Slot-cone Generator technology is integrated into the outer harbor breakwater and jetty reconstruction projects. In the last years extensive studies have been performed on the hydraulic and the structural response of this converter, with the aim of optimizing the design process. The investigations have been conducted by physical model tests and numerical simulations and many results have been published on both conference proceedings and journals. The main scope of this paper is reviewing the most significant findings, to provide the reader with an organic overview on the present status of knowledge.

  12. Modeling the Energy Performance of LoRaWAN.

    Science.gov (United States)

    Casals, Lluís; Mir, Bernat; Vidal, Rafael; Gomez, Carles

    2017-10-16

    LoRaWAN is a flagship Low-Power Wide Area Network (LPWAN) technology that has highly attracted much attention from the community in recent years. Many LoRaWAN end-devices, such as sensors or actuators, are expected not to be powered by the electricity grid; therefore, it is crucial to investigate the energy consumption of LoRaWAN. However, published works have only focused on this topic to a limited extent. In this paper, we present analytical models that allow the characterization of LoRaWAN end-device current consumption, lifetime and energy cost of data delivery. The models, which have been derived based on measurements on a currently prevalent LoRaWAN hardware platform, allow us to quantify the impact of relevant physical and Medium Access Control (MAC) layer LoRaWAN parameters and mechanisms, as well as Bit Error Rate (BER) and collisions, on energy performance. Among others, evaluation results show that an appropriately configured LoRaWAN end-device platform powered by a battery of 2400 mAh can achieve a 1-year lifetime while sending one message every 5 min, and an asymptotic theoretical lifetime of 6 years for infrequent communication.

  13. Modeling the Energy Performance of LoRaWAN

    Directory of Open Access Journals (Sweden)

    Lluís Casals

    2017-10-01

    Full Text Available LoRaWAN is a flagship Low-Power Wide Area Network (LPWAN technology that has highly attracted much attention from the community in recent years. Many LoRaWAN end-devices, such as sensors or actuators, are expected not to be powered by the electricity grid; therefore, it is crucial to investigate the energy consumption of LoRaWAN. However, published works have only focused on this topic to a limited extent. In this paper, we present analytical models that allow the characterization of LoRaWAN end-device current consumption, lifetime and energy cost of data delivery. The models, which have been derived based on measurements on a currently prevalent LoRaWAN hardware platform, allow us to quantify the impact of relevant physical and Medium Access Control (MAC layer LoRaWAN parameters and mechanisms, as well as Bit Error Rate (BER and collisions, on energy performance. Among others, evaluation results show that an appropriately configured LoRaWAN end-device platform powered by a battery of 2400 mAh can achieve a 1-year lifetime while sending one message every 5 min, and an asymptotic theoretical lifetime of 6 years for infrequent communication.

  14. Determinants of energy sector performance in Iraq, 2003 to 2005

    International Nuclear Information System (INIS)

    Tiedemann, K.H.

    2007-01-01

    Iraq's energy sector was rehabilitated from 2003 to 2005. The focus of rehabilitation was on restoring Iraq's electricity and oil infrastructure to pre-war production levels; delivering electricity and refined fuels for domestic consumption; and delivering electricity and oil security. This paper provided an analysis of the impact of Coalition efforts and insurgent activities on energy sector performance using time-series models. The paper presented a simple three-equation model consisting of an insurgent attack equation, an investment equation, and production function. The paper also discussed the phases of the insurgency in Iraq, with particular reference to the beginning of the insurgency; initial bombing campaign; escalation of the insurgency; and intra-Iraqi conflict. Key energy sector indicators and regression results were also presented for oil production; diesel production; gasoline production; oil exports; and production and consumption of electricity. It was concluded that expenditures by the United States on oil infrastructure appear to have been relatively efficiently spent. 16 refs., 9 tabs

  15. Are mediation clauses binding and mandatory?

    Directory of Open Access Journals (Sweden)

    Constantinescu Miruna

    2017-06-01

    Full Text Available This study analyses the legal force of mediation clauses in the common law systems and civil law systems with a main focus on the Romanian approach. First, the introductory section illustrates the paradox between the concept of binding and mandatory effect and the mediation mechanism, a voluntary manner to settle disputes. Notwithstanding, the possibility to coerce the parties to engage into a mediation, the voluntary character of the process is illustrated by the parties’ freedom to decide whether they settle or not. Second, the role of mediation clause is analysed and its advantages are briefly described. Third, the non-compliance of the prior mediation mechanism is presented, the starting point of the discussion being represented by the manner in which the parties drafted the mediation clause. A carefully drafted mediation clause, reflecting the parties’ consent, can determine a court or an arbitral tribunal to enforce such clause. Fourth, the study ends by mentioning the approach adopted by different national courts, emphasizing the Romanian legal perspective.

  16. Tehachapi Wind Energy Storage Project - Technology Performance Report #3

    Energy Technology Data Exchange (ETDEWEB)

    Pinsky, Naum [Southern California Edison, Rosemead, CA (United States); O' Neill, Lori [Southern California Edison, Rosemead, CA (United States)

    2017-03-31

    The TSP is located at SCE’s Monolith Substation in Tehachapi, California. The 8 MW, 4 hours (32 MWh) BESS is housed in a 6,300 square foot facility and 2 x 4 MW/4.5 MVA smart inverters are on a concrete pad adjacent to the BESS facility. The project will evaluate the capabilities of the BESS to improve grid performance and assist in the integration of large-scale intermittent generation, e.g., wind. Project performance was measured by 13 specific operational uses: providing voltage support and grid stabilization, decreasing transmission losses, diminishing congestion, increasing system reliability, deferring transmission investment, optimizing renewable-related transmission, providing system capacity and resources adequacy, integrating renewable energy (smoothing), shifting wind generation output, frequency regulation, spin/non-spin replacement reserves, ramp management, and energy price arbitrage. Most of the operations either shift other generation resources to meet peak load and other electricity system needs with stored electricity, or resolve grid stability and capacity concerns that result from the interconnection of intermittent generation. SCE also demonstrated the ability of lithium ion battery storage to provide nearly instantaneous maximum capacity for supply-side ramp rate control to minimize the need for fossil fuel-powered back-up generation. The project began in October, 2010 and will continue through December, 2016.

  17. Fenestration system energy performance research, implementation, and international harmonization

    Energy Technology Data Exchange (ETDEWEB)

    McGowan, Raymond F [National Fenestration Rating Council, Greenbelt, MD (United States)

    2014-12-23

    The research conducted by the NFRC and its contractors adds significantly to the understanding of several areas of investigation. NFRC enables manufacturers to rate fenestration energy performance to comply with building energy codes, participate in ENERGY STAR, and compete fairly. NFRC continuously seeks to improve its ratings and also seeks to simplify the rating process. Several research projects investigated rating improvement potential such as • Complex Product VT Rating Research • Window 6 and Therm 6 Validation Research Project • Complex Product VT Rating Research Conclusions from these research projects led to important changes and increased confidence in the existing NFRC rating process. Conclusions from the Window 6/Therm 6 project will enable window manufacturers to rate an expanded array of products and improve existing ratings. Some research lead to an improved new rating method called the Component Modeling Approach. A primary goal of the CMA was a simplification of the commercial energy rating process to increase participation and make the commercial industry more competitive and code compliant. The project below contributed towards CMA development: • Component Modeling Approach Condensation Resistance Research NFRC continues to implement the Component Modeling Approach program. The program includes the CMA software tool, CMAST, and several procedural documents to govern the certification process. This significant accomplishment was a response the commercial fenestration industry’s need for a simplification of the present NFRC energy rating method (named site built). To date, most commercial fenestration is self-rated by a variety of techniques. The CMA enables commercial fenestration manufacturers to rate according to the NFRC 100/200 as most commercial energy codes require. International Harmonization NFRC achieved significant international harmonization success by continuing its licensing agreements with the Australian Fenestration

  18. Energy efficient mechanisms for high-performance Wireless Sensor Networks

    Science.gov (United States)

    Alsaify, Baha'adnan

    2009-12-01

    Due to recent advances in microelectronics, the development of low cost, small, and energy efficient devices became possible. Those advances led to the birth of the Wireless Sensor Networks (WSNs). WSNs consist of a large set of sensor nodes equipped with communication capabilities, scattered in the area to monitor. Researchers focus on several aspects of WSNs. Such aspects include the quality of service the WSNs provide (data delivery delay, accuracy of data, etc...), the scalability of the network to contain thousands of sensor nodes (the terms node and sensor node are being used interchangeably), the robustness of the network (allowing the network to work even if a certain percentage of nodes fails), and making the energy consumption in the network as low as possible to prolong the network's lifetime. In this thesis, we present an approach that can be applied to the sensing devices that are scattered in an area for Sensor Networks. This work will use the well-known approach of using a awaking scheduling to extend the network's lifespan. We designed a scheduling algorithm that will reduce the delay's upper bound the reported data will experience, while at the same time keeps the advantages that are offered by the use of the awaking scheduling -- the energy consumption reduction which will lead to the increase in the network's lifetime. The wakeup scheduling is based on the location of the node relative to its neighbors and its distance from the Base Station (the terms Base Station and sink are being used interchangeably). We apply the proposed method to a set of simulated nodes using the "ONE Simulator". We test the performance of this approach with three other approaches -- Direct Routing technique, the well known LEACH algorithm, and a multi-parent scheduling algorithm. We demonstrate a good improvement on the network's quality of service and a reduction of the consumed energy.

  19. Technology Performance Report: Duke Energy Notrees Wind Storage Demonstration Project

    Energy Technology Data Exchange (ETDEWEB)

    Wehner, Jeff [Duke Energy Renewables, Charlotte, NC (United States); Mohler, David [Duke Energy Renewables, Charlotte, NC (United States); Gibson, Stuart [Duke Energy Renewables, Charlotte, NC (United States); Clanin, Jason [Duke Energy Renewables, Charlotte, NC (United States); Faris, Don [Duke Energy Renewables, Charlotte, NC (United States); Hooker, Kevin [Duke Energy Renewables, Charlotte, NC (United States); Rowand, Michael [Duke Energy Renewables, Charlotte, NC (United States)

    2015-11-01

    Duke Energy Renewables owns and operates the Notrees Wind Farm in west Texas’s Ector and Winkler counties. The wind farm, which was commissioned in April 2009, has a total capacity of 152.6 MW generated by 55 Vestas V82 turbines, one Vestas 1-V90 experimental turbine, and 40 GE 1.5-MW turbines. The Vestas V82 turbines have a generating capacity of 1.65 MW each, the Vestas V90 turbine has a generating capacity of 1.86 MW, and the GE turbines have a generating capacity of 1.5 MW each. The objective of the Notrees Wind Storage Demonstration Project is to validate that energy storage increases the value and practical application of intermittent wind generation and is commercially viable at utility scale. The project incorporates both new and existing technologies and techniques to evaluate the performance and potential of wind energy storage. In addition, it could serve as a model for others to adopt and replicate. Wind power resources are expected to play a significant part in reducing greenhouse gas emissions from electric power generation by 2030. However, the large variability and intermittent nature of wind presents a barrier to integrating it within electric markets, particularly when competing against conventional generation that is more reliable. In addition, wind power production often peaks at night or other times when demand and electricity prices are lowest. Energy storage systems can overcome those barriers and enable wind to become a valuable asset and equal competitor to conventional fossil fuel generation.

  20. Performance Evaluation of Lower-Energy Energy Storage Alternatives for Full-Hybrid Vehicles; NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    Gonder, J.; Cosgrove, J.; Pesaran, A.

    2014-02-11

    Automakers have been mass producing hybrid electric vehicles (HEVs) for well over a decade, and the technology has proven to be very effective at reducing per-vehicle fuel use. However, the incremental cost of HEVs such as the Toyota Prius or Ford Fusion Hybrid remains several thousand dollars higher than the cost of comparable conventional vehicles, which has limited HEV market penetration. The b b b b battery energy storage device is typically the component with the greatest contribution toward this cost increment, so significant cost reductions/performance improvements to the energy storage system (ESS) can correspondingly improve the vehicle-level cost/benefit relationship. Such an improvement would in turn lead to larger HEV market penetration and greater aggregate fuel savings. The United States Advanced Battery Consortium (USABC) and the U.S. Department of Energy (DOE) Energy Storage Program managers asked the National Renewable Energy Laboratory (NREL) to collaborate with a USABC Workgroup and analyze the trade-offs between vehicle fuel economy and reducing the decade-old minimum energy requirement for power-assist HEVs. NREL’s analysis showed that significant fuel savings could still be delivered from an ESS with much lower energy storage than the previous targets, which prompted USABC to issue a new set of lower-energy ESS (LEESS) targets that could be satisfied by a variety of technologies. With support from DOE, NREL has developed an HEV test platform for in-vehicle performance and fuel economy validation testing of the hybrid system using such LEESS devices. This presentation describes development of the vehicle test platform, and laboratory as well as in-vehicle evaluation results with alternate energy storage configurations as compared to the production battery system. The alternate energy storage technologies considered include lithium-ion capacitors -- i.e., asymmetric electrochemical energy storage devices possessing one electrode with battery

  1. What do dental students think about mandatory laptop programs?

    Science.gov (United States)

    Hendricson, William; Eisenberg, Elise; Guest, Gary; Jones, Pamela; Johnson, Lynn; Panagakos, Fotinos; McDonald, James; Cintron, Laura

    2006-05-01

    at their schools. The majority of students (63 percent) reported that the laptop and associated software were not essential for successful performance in their courses primarily because few instructors had modified their courses to take advantage of laptop capacities. Slightly more than half of the students reported their training was good or excellent, but felt that classroom-based "one size fits all" training was not effective. Less than 15 percent of the students reported that they had made substantial changes in their study habits as a consequence of the laptop program. The benefits perceived by students were primarily related to enhanced email communication with classmates and instructors and convenient access to the Internet and teachers' PowerPoint presentations. Implementation barriers included the inconvenience of carrying laptops to classes, lack of incentive to use the laptop and software because instructors did not require it, and poor quality software. Only 32 percent of students agreed that the value of the laptop and associated software was equal to the added tuition costs. Less than half of the students perceived that the laptop and software had improved the quality of their education, but more than 70 percent rated their overall experiences with laptops as "okay," "good," or "excellent." Freshmen expressed significantly more positive attitudes about the frequency of use, cost-effectiveness, educational value, and overall quality of laptops and bundled software than did upperclassmen. A significantly higher percentage of students at schools affiliated with a software vendor reported that laptops were essential in courses than students at schools with locally produced software, but students at vendor-supplied schools rated the cost-effectiveness significantly lower. Overall, students' assessment of mandatory laptop programs was mixed although freshmen provided significantly more positive responses than did upperclassmen. Incorporation of the e

  2. Performance Evaluation of Bluetooth Low Energy: A Systematic Review

    Directory of Open Access Journals (Sweden)

    Jacopo Tosi

    2017-12-01

    Full Text Available Small, compact and embedded sensors are a pervasive technology in everyday life for a wide number of applications (e.g., wearable devices, domotics, e-health systems, etc.. In this context, wireless transmission plays a key role, and among available solutions, Bluetooth Low Energy (BLE is gaining more and more popularity. BLE merges together good performance, low-energy consumption and widespread diffusion. The aim of this work is to review the main methodologies adopted to investigate BLE performance. The first part of this review is an in-depth description of the protocol, highlighting the main characteristics and implementation details. The second part reviews the state of the art on BLE characteristics and performance. In particular, we analyze throughput, maximum number of connectable sensors, power consumption, latency and maximum reachable range, with the aim to identify what are the current limits of BLE technology. The main results can be resumed as follows: throughput may theoretically reach the limit of ~230 kbps, but actual applications analyzed in this review show throughputs limited to ~100 kbps; the maximum reachable range is strictly dependent on the radio power, and it goes up to a few tens of meters; the maximum number of nodes in the network depends on connection parameters, on the network architecture and specific device characteristics, but it is usually lower than 10; power consumption and latency are largely modeled and analyzed and are strictly dependent on a huge number of parameters. Most of these characteristics are based on analytical models, but there is a need for rigorous experimental evaluations to understand the actual limits.

  3. Performance of modified greenhouse dryer with thermal energy storage

    Directory of Open Access Journals (Sweden)

    Om Prakash

    2016-11-01

    Full Text Available In this attempt, the main goal is to do annual performance, environomical analysis, energy analysis and exergy analysis of the modified greenhouse dryer (MGD operating under active mode (AM and passive mode (PM. Thermal storage is being applied on the ground of MGD. It is applied in three different ways namely barren floor, floor covered with black PVC sheet (PVC and Black Coated. Experimental study of dryers in no-load conditions reveals that floor covered with a black PVC sheet is more conducive for drying purpose than other floors. The MGD under AM is found to be more effective as compared to PM for tomato and capsicum, which are high moisture content crops. For medium moisture content crop (potato chips, both dryers show relatively similar drying performance. Crops dried inside the greenhouse dryer are found to be more nutrient than open sun dried crops. The payback period of the modified greenhouse dryer under passive mode is found to be 1.11 years. However, for the active mode of the modified greenhouse dryer is only 1.89 years. The embodied energy of the passive mode of the dryer is a 480.277 kWh and 628.73 kWh for the active mode of the dryer. The CO2 emissions per annum for passive and active mode greenhouse dryers are found to be 13.45 kg and 17.6 kg respectively. The energy payback time, carbon mitigation and carbon credit have been calculated based type of crop dried. The range of exergy efficiency is 29%–86% in MGD under PM and 30%–78% in the MGD under AM. The variation of Heat utilization factor (HUF for MGD under PM is 0.12–0.38 and 0.26–0.53 for MGD under AM. The range of co-efficient of performances (COP for MGD under PM is 0.55–0.87 and 0.58–0.73 for MGD under AM.

  4. Performance of a transmutation advanced device for sustainable energy application

    Energy Technology Data Exchange (ETDEWEB)

    Garcia, C.; Rosales, J.; Garcia, L. [Instituto Superior de Tecnologias y Ciencias Aplicadas (INSTEC), La Habana (Cuba); Perez-Navarro, A.; Escriva, A. [Universidad Politecnica de Valencia, Valencia (Spain). Inst. de Ingenieria Energetica; Abanades, A. [Universidad Politecnica de Madrid (Spain). Grupo de Modelizacion de Sistemas Termoenergeticos

    2009-07-01

    Preliminary studies have been performed to design a device for nuclear waste transmutation and hydrogen generation based on a gas cooled pebble bed accelerator driven system, TADSEA (transmutation advanced device for sustainable energy application). In previous studies we have addressed the viability of an ADS Transmutation device that uses as fuel wastes from the existing LWR power plants, encapsulated in graphite in the form of pebble beds, being cooled by helium which enables high temperatures, in the order of 1200 K, to facilitate hydrogen generation from water either by high temperature electrolysis or by thermo chemical cycles. To design this device several configurations were studied, including several reactors thickness, to achieve the desired parameters, the transmutation of nuclear waste and the production of 100 MW. of thermal power. In this paper we are presenting new studies performed on deep burn in-core fuel management strategy for LWR waste. We analyze the fuel cycle on TADSEA device based on driver and transmutation fuel that were proposed for the General Atomic design of a gas turbine-modular helium reactor. We compare the transmutation results of the three fuel management strategies, using driven and transmutation, and standard LWR spend fuel, and present several parameters that describe the neutron performance of TADSEA nuclear core as the fuel and moderator temperature reactivity coefficients and transmutation chain. (author)

  5. Performance of a transmutation advanced device for sustainable energy application

    International Nuclear Information System (INIS)

    Garcia, C.; Rosales, J.; Garcia, L.; Perez-Navarro, A.; Escriva, A.; Abanades, A.

    2009-01-01

    Preliminary studies have been performed to design a device for nuclear waste transmutation and hydrogen generation based on a gas cooled pebble bed accelerator driven system, TADSEA (transmutation advanced device for sustainable energy application). In previous studies we have addressed the viability of an ADS Transmutation device that uses as fuel wastes from the existing LWR power plants, encapsulated in graphite in the form of pebble beds, being cooled by helium which enables high temperatures, in the order of 1200 K, to facilitate hydrogen generation from water either by high temperature electrolysis or by thermo chemical cycles. To design this device several configurations were studied, including several reactors thickness, to achieve the desired parameters, the transmutation of nuclear waste and the production of 100 MW. of thermal power. In this paper we are presenting new studies performed on deep burn in-core fuel management strategy for LWR waste. We analyze the fuel cycle on TADSEA device based on driver and transmutation fuel that were proposed for the General Atomic design of a gas turbine-modular helium reactor. We compare the transmutation results of the three fuel management strategies, using driven and transmutation, and standard LWR spend fuel, and present several parameters that describe the neutron performance of TADSEA nuclear core as the fuel and moderator temperature reactivity coefficients and transmutation chain. (author)

  6. Candle Soot-Driven Performance Enhancement in Pyroelectric Energy Conversion

    Science.gov (United States)

    Azad, Puneet; Singh, V. P.; Vaish, Rahul

    2018-05-01

    We observed substantial enhancement in pyroelectric output with the help of candle soot coating on the surface of lead zirconate titanate (PZT). Candle soot of varying thicknesses was coated by directly exposing pyroelectric material to the candle flame. The open-circuit pyroelectric voltage and closed-circuit pyroelectric current were recorded while applying infrared heating across the uncoated and candle soot-coated samples for different heating and cooling cycles. In comparison to the uncoated sample, the maximum open-circuit voltage improves seven times for the candle soot-coated sample and electric current increases by eight times across a resistance of 10Å. Moreover, the harvested energy is enhanced by 50 times for candle soot-coated sample. Results indicate that candle soot coating is an effective and economic method to improve infrared sensing performance of pyroelectric materials.

  7. Power/energy use cases for high performance computing

    Energy Technology Data Exchange (ETDEWEB)

    Laros, James H. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Kelly, Suzanne M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Hammond, Steven [National Renewable Energy Lab. (NREL), Golden, CO (United States); Elmore, Ryan [National Renewable Energy Lab. (NREL), Golden, CO (United States); Munch, Kristin [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2013-12-01

    Power and Energy have been identified as a first order challenge for future extreme scale high performance computing (HPC) systems. In practice the breakthroughs will need to be provided by the hardware vendors. But to make the best use of the solutions in an HPC environment, it will likely require periodic tuning by facility operators and software components. This document describes the actions and interactions needed to maximize power resources. It strives to cover the entire operational space in which an HPC system occupies. The descriptions are presented as formal use cases, as documented in the Unified Modeling Language Specification [1]. The document is intended to provide a common understanding to the HPC community of the necessary management and control capabilities. Assuming a common understanding can be achieved, the next step will be to develop a set of Application Programing Interfaces (APIs) to which hardware vendors and software developers could utilize to steer power consumption.

  8. Energy Performance of Verandas in the Building Retrofit Process

    Directory of Open Access Journals (Sweden)

    Rossano Albatici

    2016-05-01

    Full Text Available Passive solar elements for both direct and indirect gains, are systems used to maintain a comfortable living environment while saving energy, especially in the building energy retrofit and adaptation process. Sunspaces, thermal mass and glazing area and orientation have been often used in the past to guarantee adequate indoor conditions when mechanical devices were not available. After a period of neglect, nowadays they are again considered as appropriate systems to help face environmental issues in the building sector, and both international and national legislation takes into consideration the possibility of including them in the building planning tools, also providing economic incentives. Their proper design needs dynamic simulation, often difficult to perform and time consuming. Moreover, results generally suffer from several uncertainties, so quasi steady-state procedures are often used in everyday practice with good results, but some corrections are still needed. In this paper, a comparative analysis of different solutions for the construction of verandas in an existing building is presented, following the procedure provided by the slightly modified and improved Standard EN ISO 13790:2008. Advantages and disadvantages of different configurations considering thermal insulation, windows typology and mechanical ventilation systems are discussed and a general intervention strategy is proposed. The aim is to highlight the possibility of using sunspaces in order to increase the efficiency of the existing building stock, considering ease of construction and economic viability.

  9. High performance computing in power and energy systems

    Energy Technology Data Exchange (ETDEWEB)

    Khaitan, Siddhartha Kumar [Iowa State Univ., Ames, IA (United States); Gupta, Anshul (eds.) [IBM Watson Research Center, Yorktown Heights, NY (United States)

    2013-07-01

    The twin challenge of meeting global energy demands in the face of growing economies and populations and restricting greenhouse gas emissions is one of the most daunting ones that humanity has ever faced. Smart electrical generation and distribution infrastructure will play a crucial role in meeting these challenges. We would need to develop capabilities to handle large volumes of data generated by the power system components like PMUs, DFRs and other data acquisition devices as well as by the capacity to process these data at high resolution via multi-scale and multi-period simulations, cascading and security analysis, interaction between hybrid systems (electric, transport, gas, oil, coal, etc.) and so on, to get meaningful information in real time to ensure a secure, reliable and stable power system grid. Advanced research on development and implementation of market-ready leading-edge high-speed enabling technologies and algorithms for solving real-time, dynamic, resource-critical problems will be required for dynamic security analysis targeted towards successful implementation of Smart Grid initiatives. This books aims to bring together some of the latest research developments as well as thoughts on the future research directions of the high performance computing applications in electric power systems planning, operations, security, markets, and grid integration of alternate sources of energy, etc.

  10. Realizing High-Performance Buildings; NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2015-03-02

    High-performance buildings (HPBs) are exceptional examples of both design and practice. Their energy footprints are small, and these are buildings that people want to work in because of their intelligent structure, operations, and coincident comfort. However, the operation of most buildings, even ones that are properly constructed and commissioned at the start, can deviate significantly from the original design intent over time, particularly due to control system overrides and growing plug and data center loads. With early planning for systems such as submetering and occupant engagement tools, operators can identify and remedy the problems. This guide is a primer for owners and owners’ representatives who are pursuing HPBs. It describes processes that have been successful in the planning, procurement, and operation of HPBs with exceptional energy efficiency. Much of the guidance offered results from a series of semi-structured conference calls with a technical advisory group of 15 owners and operators of prominent HPBs in the United States. The guide provides a prescription for planning, achieving, and maintaining an HPB. Although the guide focuses on the operations stage of buildings, many of the operations practices are specified during the planning stage.

  11. Electrostatic direct energy converter performance and cost scaling laws

    International Nuclear Information System (INIS)

    Hoffman, M.A.

    1977-08-01

    This study is concerned with electrostatic type direct energy converters for direct recovery of a large fraction of the plasma ion energy from fusion reactors. Simplified equations are presented for each of the important loss mechanisms in both single-stage direct converters and multistage ''Venetian Blind'' type direct converters. These equations can be used to estimate the efficiency and electric power output of the direct converter subsystem. Scaling relations for the cost of each major component in the direct converter subsystem are also given; these include the vacuum tank, direct converter modules, the DC power conditioning equipment, cryogenic vacuum pumping system and the thermal bottoming plant. The performance and cost scaling laws have been developed primarily for use in overall fusion power plant systems codes. However, to illustrate their utility, cost-effectiveness studies of two specific reference direct converter designs are presented in terms of the specific capital costs (i.e., the capital cost per unit electric power produced) for the Direct Converter Subsystem alone. Some examples of design improvements which can significantly reduce the specific capital costs of the Direct Converter Subsystem are also given

  12. Energy Efficiency: The Implementation of Minimum Energy Performance Standard (MEPS Application on Home Appliances for Residential

    Directory of Open Access Journals (Sweden)

    Rahman K.A

    2016-01-01

    Full Text Available Generally, Minimum Energy Performance Standard (MEPS has been widespread across the country especially developed country. However, most consumers do not even know about the MEPS. Without sufficient knowledge, much energy have been wasted before this. The aim of this study is to review the implementation of MEPS of Asia country and to compare electricity consumption of home appliances with star rating and without star rating. In order to fulfil the objectives of the study, the equipment must be chosen correctly and must be learned properly. The home appliances that will be used also need to be chosen so that the comparison between the appliances will be matched correctly. To understand the results, the analysis was done using graphs and table. The purpose of using graph and table is to understand the comparison between appliances more clearly. The results show that home appliances with MEPS is more efficient on energy saving rather than without MEPS. This is the evidence as a method to educate a consumer on energy saving.

  13. Securing Gender Equality through a Nexus of Energy Policy Performance and Relative Political Performance

    Science.gov (United States)

    Perkins-Ozuagiemhe, Andrea Christen

    This dissertation presents what is believed to be the first empirical study that measures the effect of increasing access to modern household energy sources upon advancing gender equality within developing countries. As a powerful and fundamental public infrastructural socio-economic building block, improved access to modern energy in developing countries delivers the necessary economic ingredient of time as a major component of household production and consumption and captures the interdependence between market and household economies. Thus, because it has been empirically proven that men and women differ in their utilization of household energy with women spending more time engaged in non-market household labor than men, improving access to modern household energy in developing countries, especially in rural areas, theoretically would disproportionately affect women's lives. Essentially, the element of "time" not only extends the day for women to use towards more economically and educationally productive activities, but also lessens the burden of domestic chores from women with technological advancements in more time-efficient household appliances and cleaner modern energy sources. This dissertation introduces gender differentiation in a model in the form of a gender relative status composite measure comparing socio-economic achievements in secondary education, life expectancy, and labor force participation rates by varying degree of demographic transition, thereby, measuring the effect of improved access to modern household energy upon overall gender equality. Fixed effects panel regressions employing a Driscoll-Kraay non-parametric covariance matrix, and estimated and interpreted adjusted predictions and marginal effects of the two-way interaction between a country's available access to residential electric power (kWh per capita) and the level of relative political performance against predicted values of gender relative status are employed. The models confirm

  14. Market response to the public display of energy performance rating at property sales

    DEFF Research Database (Denmark)

    Jensen, Ole Michael; Hansen, Anders Rhiger; Kragh, Jesper

    2016-01-01

    Energy labels have generally received positive response from consumers and have moved the market for white goods and cars in the direction of more energy-efficient products. On the real estate market, it was expected that an energy label, rating the energy performance of a property based on a nat......Energy labels have generally received positive response from consumers and have moved the market for white goods and cars in the direction of more energy-efficient products. On the real estate market, it was expected that an energy label, rating the energy performance of a property based...... on a national energy performance certificate (EPC) might receive similar response. However, in Denmark no response to the energy performance rating was observed for 15 years. This was a surprise considering that Denmark was the first country to implement an A to G rating of the energy performance of buildings...

  15. 32 CFR 2001.33 - Mandatory review for declassification.

    Science.gov (United States)

    2010-07-01

    ... information sought with a reasonable amount of effort. Requests for broad types of information, entire file... information pertains to intelligence activities, the Director of National Intelligence. (d) Intelligence information. Mandatory declassification review requests for information pertaining to intelligence sources...

  16. 25 CFR 1000.225 - Are meetings or discussions mandatory?

    Science.gov (United States)

    2010-04-01

    ... FUNDING AGREEMENTS UNDER THE TRIBAL SELF-GOVERNMENT ACT AMENDMENTS TO THE INDIAN SELF-DETERMINATION AND EDUCATION ACT Waiver of Regulations § 1000.225 Are meetings or discussions mandatory? No, a meeting with the...

  17. Mandatory certification of personal protection equipment against ionizing radiation

    International Nuclear Information System (INIS)

    Palacios, Tulio A.

    2000-01-01

    This paper analyze the regulations establishing mandatory certification of personal protection equipment, including those aim to protect against ionizing radiation due to the external irradiation and to the radioactive contamination. (author)

  18. Cost and performance of coal-based energy in Brazil

    International Nuclear Information System (INIS)

    Temchin, J.; DeLallo, M.R.

    1998-01-01

    As part of the US Department of Energy's (DOE) efforts to establish the strategic benefits of Clean Coal Technologies (CCT), there is a need to evaluate the specific market potential where coal is a viable option. One such market is Brazil, where significant growth in economic development requires innovative and reliable technologies to support the use of domestic coal. While coal is Brazil's most abundant and economic fossil energy resource, it is presently under utilized in the production of electrical power. This report presents conceptual design for pulverized coal (PC) and circulating fluidized-bed combustion (CFBC) options with resulting capital, operating and financial parameters based on Brazil application conditions. Recent PC and CFBC plant capital costs have dropped with competition in the generation market and have established a competitive position in power generation. Key issues addressed in this study include: Application of market based design approach for FBC and PC, which is competitive within the current domestic, and international power generation markets. Design, fabrication, purchase, and construction methods which reduce capital investment while maintaining equipment quality and plant availability. Impact on coast and performance from application of Brazilian coals, foreign trade and tax policies, construction logistics, and labor requirements. Nominal production values of 200 MWe and 400 MWe were selected for the CFBC power plant and 400 MWe for the PC. The 400 MWe size was chosen to be consistent with the two largest Brazilian PC units. Fluidized bed technology, with limited experience in single units over 200 MW, would consist of two 200 MWe circulating fluidized bed boilers supplying steam to one steam turbine for the 400 MWe capacity. A 200 MWe capacity unit was also developed for CFBC option to support opportunities in re-powering and where specific site or other infrastructure constraints limit production

  19. Postpercutaneous Nephrolithotomy Nephrostogram: Is It Mandatory? A Single Center Experience

    Directory of Open Access Journals (Sweden)

    Abdul Rouf Khawaja

    2014-01-01

    Full Text Available Aims and Objective. “Postpercutaneous nephrolithotomy nephrostogram” (PPNN is routinely performed in most of the centers. No published series could be found in the literature without post percutaneous nephrolithotomy nephrostogram. Hence, the aim of our study is to highlight that post percutaneous nephrolithotomy nephrostogram is not mandatory and it only adds to cost and morbidity without adding any information in the management of such patients. Methods. It was a prospective study from 2005 to 2012, conducted in our institute. It included 119 patients of renal stones who underwent percutaneous nephrolithotomy performed under the guidance of a single surgeon. Postoperative nephrostogram was not done in any of the patients. Results. Complete stone clearance was achieved in 97.5% of patients and 2.5% of patients needed two to three sessions of ESWL later on. None of the patients needed second look percutaneous nephrolithotomy or nephrostogram. Conclusion. Postpercutaneous nephrolithotomy nephrostogram increases chances of infection, inconvenience, contrast related complications, and cost, with no added advantage over plain X-ray KUB, and it should not be done as a routine investigation prior to the removal of PCN tube in patients with complete stone clearance.

  20. Progress towards the specification of embodied energy performance criteria for New Zealand buildings

    Energy Technology Data Exchange (ETDEWEB)

    Baird, G.; Alcorn, A.; Wood, P.; Storey, J. B. [Victoria Univ., Wellington (New Zealand). School of Architecture; Jaques, R. [Building Research Association of New Zealand, Inc. (New Zealand)

    1998-11-01

    Incorporation of embodied energy performance criteria into New Zealand`s recently adopted performance-based building code is discussed. The paper also describes the concept of the Building Code and its energy related clauses and standards, work done to date to update the building materials` energy coefficients, and the progress made in using an embodied energy database. The purpose, desirability and likely pitfalls of such criteria, ways of specifying minimum performance, and relationships with operating energy criteria are also reviewed.

  1. Mandatory adoption of business risk disclosure: evidence from Japanese firms

    OpenAIRE

    KIM, Hyonok; YASUDA, Yukihiro

    2016-01-01

    We take advantage of institutional changes and its characteristics in Japan to empirically examine mandatory business risk disclosure. We find that there is a negative impact on total risk from the introduction of mandatory business risk disclosure. This suggests that an increase in business risk disclosure reduces a firm's cost of capital, which is contrary to the results of previous research. However, we also find that there is a positive relationship across firms and years after inception ...

  2. What drives the comparability effect of mandatory IFRS adoption?

    OpenAIRE

    Stefano Cascino; Joachim Gassen

    2015-01-01

    We investigate the effects of mandatory IFRS adoption on the comparability of financial accounting information. Using two comparability proxies based on De Franco et al. [2011] and a comparability proxy based on the degree of information transfer, our results suggest that the overall comparability effect of mandatory IFRS adoption is marginal. We hypothesize that firm-level heterogeneity in IFRS compliance explains the limited comparability effect. To test this conjecture, we first hand-colle...

  3. Intended and unintended consequences of mandatory IFRS adoption

    OpenAIRE

    Brüggemann, Ulf; Hitz, Jörg-Markus; Sellhorn, Thorsten

    2012-01-01

    This paper discusses empirical evidence on the economic consequences of mandatory adoption of International Financial Reporting Standards (IFRS) in the European Union (EU) and provides suggestions on how future research can add to our understanding of these effects. Based on the explicitly stated objectives of the EU‟s so-called „IAS Regulation‟, we distinguish between intended and unintended consequences of mandatory IFRS adoption. Empirical research on the intended consequences generally fa...

  4. International Trade in Biotechnology Products and Strategic Mandatory Labelling

    OpenAIRE

    Jinji, Naoto

    2003-01-01

    This paper examines strategic motives to impose mandatory labelling of biotechnology products when consumers perceive these products as being of lower quality. When a foreign dominant firm produces a biotechnology product, it is shown that without mandatory labelling fringe firms, which produce a conventional product, provide voluntary labelling as long as voluntary labelling is fully credible. Information on which product is biotechnologically engineered is hence completely disclosed without...

  5. Environmental performance assessment of utility boiler energy conversion systems

    International Nuclear Information System (INIS)

    Li, Changchun; Gillum, Craig; Toupin, Kevin; Park, Young Ho; Donaldson, Burl

    2016-01-01

    Highlights: • Sustainability analyses of utility boilers are performed. • Natural gas fired boilers have the least CO_2 emissions in fossil fueled boilers. • Solar boilers rank last with an emergy yield ratio of 1.2. • Biomass boilers have the best emergy sustainability index. - Abstract: A significant amount of global electric power generation is produced from the combustion of fossil fuels. Steam boilers are one of the most important components for steam and electricity production. The objective of this paper is to establish a theoretical framework for the sustainability analysis of a utility boiler. These analyses can be used by decision-makers to diagnose and optimize the sustainability of a utility boiler. Seven utility boiler systems are analyzed using energy and embodied solar energy (emergy) principles in order to evaluate their environmental efficiencies. They include a subcritical coal fired boiler, a supercritical coal fired boiler, an oil fired boiler, a natural gas fired boiler, a concentrating solar power boiler utilizing a tower configuration, a biomass boiler, and a refuse derived fuel boiler. Their relative environmental impacts were compared. The results show that the natural gas boiler has significantly lower CO_2 emission than an equivalent coal or oil fired boiler. The refuse derived fuel boiler has about the same CO_2 emissions as the natural gas boiler. The emergy sustainability index of a utility boiler system is determined as the measure of its sustainability from an environmental perspective. Our analyses results indicate that the natural gas boiler has a relatively high emergy sustainability index compared to other fossil fuel boilers. Converting existing coal boilers to natural gas boilers is a feasible option to achieve better sustainability. The results also show that the biomass boiler has the best emergy sustainability index and it will remain a means to utilize the renewable energy within the Rankine steam cycle. Before

  6. Hierarchical Oxide Nanostructures for High Performance Energy Storage

    Data.gov (United States)

    National Aeronautics and Space Administration — Energy storage is a major concern for space technology. Many functions on spacecraft and on the International Space Station run solely on electrical energy to power...

  7. Mandatory continuing professional education in pharmacy: the Singapore experience.

    Science.gov (United States)

    Ang, Hui-Gek; Pua, Yong-Hao; Subari, Nur Azah

    2013-08-01

    Mandatory Continuing Professional Education (CPE) for the renewal of pharmacists' practising certificate was implemented in Singapore in 2008 OBJECTIVE: To study pharmacists' perceptions and attitudes about the impact of mandatory CPE in Singapore. Singapore. Internet-based questionnaire survey, conducted between May and June 2011. Pharmacists' perceptions and attitudes toward mandatory CPE and the perceived difficulty in fulfilling the CPE requirements. The overall survey response rate was 52 % (840/1,609). Of the respondents, 32 % were non-practising, 49 % were practising in patient care areas, and 19 % were practising in non-patient care areas. More than half the pharmacists agreed that mandatory CPE (1) enhanced or increased their knowledge base and skills (70 %; 95 % CI 67-73 %), (2) motivated them to continually learn (64 %; 95 % CI, 60-67 %), and (3) motivated them to reflect on their professional practice or work (58 %; 95 % CI, 54-61 %). Mandatory CPE was not perceived to enhance or increase employability. Non-practising pharmacists appeared to have the greatest difficulty meeting the CPE requirements. In general, pharmacists value mandatory CPE more for positive professional reasons than for employability reasons. The survey results may serve as useful baseline data for future studies of pharmacists' perceptions and attitudes toward CPE in Singapore.

  8. Innovative procurement frameworks for energy performance contracting in the UK public sector

    OpenAIRE

    Nolden, Colin; Sorrell, Steve; Polzin, Friedemann

    2015-01-01

    Procurement Frameworks for Energy Performance Contracting (PFEPCs) simplify the process of negotiating, developing and implementing Energy Performance Contracts (EPCs) with Energy Service Companies (ESCOs). This paper analyses their role in promoting the implementation of cost-effective energy efficiency measures in the UK public sector. Compared to conventional approaches to procuring goods and services involving detailed specifications, PFEPCs translate the challenge of upgrading, retrofitt...

  9. 48 CFR 23.205 - Energy-savings performance contracts.

    Science.gov (United States)

    2010-10-01

    ... through Efficient Energy Management, requires an agency to make maximum use of the authority provided in... capital cost to the United States Treasury. The energy service company finances the capital costs of implementing energy conservation measures and receives, in return, a contractually determined share of the cost...

  10. Renewable energy development in China: policies, practices and performance

    NARCIS (Netherlands)

    Han, Jingyi

    2009-01-01

    Energy demand in China has risen rapidly, driven by its massive economic growth. Meanwhile, the energy system in China heavily depends on fossil fuels, which causes serious problems of climate change and air pollution. China started to develop renewable energy about 30 years ago, aiming to alleviate

  11. Thermal performance and heat transport in aquifer thermal energy storage

    NARCIS (Netherlands)

    Sommer, W.T.; Doornenbal, P.J.; Drijver, B.C.; Gaans, van P.F.M.; Leusbrock, I.; Grotenhuis, J.T.C.; Rijnaarts, H.H.M.

    2014-01-01

    Aquifer thermal energy storage (ATES) is used for seasonal storage of large quantities of thermal energy. Due to the increasing demand for sustainable energy, the number of ATES systems has increased rapidly, which has raised questions on the effect of ATES systems on their surroundings as well as

  12. Evaluation of Energy Efficiency Performance of Heated Windows

    Science.gov (United States)

    Jammulamadaka, Hari Swarup

    The study about the evaluation of the performance of the heated windows was funded by the WVU Research Office as a technical assistance award at the 2014 TransTech Energy Business Development Conference to the Green Heated Glass company/project owned by Frank Dlubak. The award supports a WVU researcher to conduct a project important for commercialization. This project was awarded to the WVU Industrial Assessment Center in 2015. The current study attempted to evaluate the performance of the heated windows by developing an experimental setup to test the window at various temperatures by varying the current input to the window. The heated double pane window was installed in an insulated box. A temperature gradient was developed across the window by cooling one side of the window using gel based ice packs. The other face of the window was heated by passing current at different wattages through the window. The temperature of the inside and outside panes, current and voltage input, room and box temperature were recorded, and used to calculate the apparent R-value of the window when not being heated vs when being heated. It has been concluded from the study that the heated double pane window is more effective in reducing heat losses by as much as 50% than a non-heated double pane window, if the window temperature is maintained close to the room temperature. If the temperature of the window is much higher than the room temperature, the losses through the window appear to increase beyond that of a non-heated counterpart. The issues encountered during the current round of experiments are noted, and recommendations provided for future studies.

  13. The use of energy management and control systems to monitor the energy performance of commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Heinemeier, Kristin Elizabeth [Univ. of California, Berkeley, CA (United States). Dept. of Architecture

    1994-12-01

    Monitored data play a very important part in the implementation and evaluation of energy conservation technologies and programs. However, these data can be expensive to collect, so there is a need for lower-cost alternatives. In many situations, using the computerized Energy Management and Control Systems (EMCSs)--already installed in many buildings--to collect these commercial building performance data has advantages over more conventional methods. This method provides data without installing incremental hardware, and the large amounts of available operational data can be a very rich resource for understanding building performance. This dissertation addresses several of these issues. One specific objective is to describe a monitoring-project planning process that includes definition of objectives, constraints, resources and approaches for the monitoring. The choice of tools is an important part of this process. The dissertation goes on to demonstrate, through eight case studies, that EMCS monitoring is possible, and to identify and categorize the problems and issues that can be encountered. These issues lead to the creation, use, and testing of a set of methods for evaluation of EMCS monitoring, in the form of guidelines. Finally, EMCS monitoring is demonstrated and compared with conventional monitoring more methodically in a detailed case study.

  14. Methodology for Modeling Building Energy Performance across the Commercial Sector

    Energy Technology Data Exchange (ETDEWEB)

    Griffith, B.; Long, N.; Torcellini, P.; Judkoff, R.; Crawley, D.; Ryan, J.

    2008-03-01

    This report uses EnergyPlus simulations of each building in the 2003 Commercial Buildings Energy Consumption Survey (CBECS) to document and demonstrate bottom-up methods of modeling the entire U.S. commercial buildings sector (EIA 2006). The ability to use a whole-building simulation tool to model the entire sector is of interest because the energy models enable us to answer subsequent 'what-if' questions that involve technologies and practices related to energy. This report documents how the whole-building models were generated from the building characteristics in 2003 CBECS and compares the simulation results to the survey data for energy use.

  15. Performance Evaluation of Radiation Sensors for the Solar Energy Sector

    Directory of Open Access Journals (Sweden)

    Laurent Vuilleumier

    2017-11-01

    Full Text Available Rotating Shadowband Irradiometers (RSI and SPN1 Sunshine Pyranometers allow determining the diffuse and direct components of solar radiation without sun trackers; they can be deployed in networks for continuous field operation with modest maintenance. Their performances are evaluated here by analyzing their errors with respect to well characterized references. The analysis is based on 1‑minute data recorded over a 15‑month period at the Payerne BSRN station in Switzerland. The analysis was applied both to the whole dataset and data subsets reflecting particular conditions to allow a better understanding of how instrument performance depends on such conditions.The overall performance for measuring global horizontal irradiance (GHI is satisfactory with deviations compatible with an expanded uncertainty of ±25 Wm−2 (±10 %. For diffuse horizontal irradiance (DfHI, RSIs exhibited errors on the order of ±20 Wm−2 (±13 % with some of them being affected by small systematic negative biases on the order of −5 Wm−2 (median. SPN1s underestimate DfHI by about −10 Wm−2 (median with a relatively large range of the expanded error distribution between −45 Wm−2 and 20 Wm−2 (−35 % to 13 %. For direct normal irradiance (DNI, the extended error range for RSIs is on the order of ±40 Wm−2 (±5–6 % with some instruments presenting no bias while others are affected by median biases up to −15 Wm−2. SPN1s exhibit a relatively large median bias of 40 Wm−2, and an extended range of the error distribution between −45 Wm−2 and 125 Wm−2 (−6 % to 19 %. Typical errors on the integrated yearly energy per unit surface area are on the order of a few percent or less (< 5 % for RSI with negligible errors on DNI for some RSI instruments. SPN1 integrated errors are negligible for GHI, but on the order of −8 % for DfHI, and between 9 % and 11 % for DNI.For RSIs, GHI and DfHI errors showed

  16. [Incidence of endophthalmitis after intravitreal injection: is antibioprophylaxis mandatory?].

    Science.gov (United States)

    Ramel, J-C; Bron, A-M; Isaico, R; Meillon, C; Binquet, C; Creuzot-Garcher, C

    2014-04-01

    Endophthalmitis is the most dreaded complication after intravitreal injection. With the rise of antiangiogenics their rate is getting higher each year. The use of antibioprophylaxis is controversial. We tried to evaluate the impact of antibioprophylaxis on intravitreal injection endophthalmitis incidence. All patients who received intravitreal injections between January 2007 and October 2012 were included in this retrospective study. Until June 2012 all patients had antibiotics the days following the injection. From July 2012 the antibiotic was replaced by an antiseptic immediately after the injection. An overall number of 11,450 injections were performed. The overall rate of endophthalmitis was 6/11,450 (0.052%). The incidence of endophthalmitis in the group with antibiotics was 3/10,144 injections (0.03%), 2 were culture proven (0.02%). The incidence in the group without antibiotics was 3/1306 (0.23%). The difference was significant (P=0.024). The incidence of endophthalmitis post-intravitreal injections seems to be lower when using antibiotics. However, a prospective study is mandatory to draw more robust conclusions. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  17. Driving forces and barriers to improved energy performance of buildings: an analysis of energy performance of Swedish buildings, 2000-2006

    Energy Technology Data Exchange (ETDEWEB)

    Fuglseth, Bente Beckstroem

    2008-06-15

    The building sector is responsible for a substantial part of energy use and green house gas emissions in Europe. This report explores driving forces and barriers to improved energy performance of buildings, using the Swedish building sector as a case. The development of energy performance of buildings in Sweden from 2000 until 2006 is explored by applying a threefold understanding of energy performance of buildings: substitution from fossil fuels to renewable energy, conversion from electrical heating to thermal energy and reduction in energy demand. Three explanatory approaches are used to analyse driving forces and barriers to improved energy performance: the techno-economic approach stresses the physical aspects of infrastructure and technologies, the institutional approach emphasizes the role of institutional factors, while the regulative approach focuses on formal rules and laws. The study concludes that all factors have promoted substitution of fossil fuels with renewable energy, while they have prevented conversion from electrical heating to thermal energy and reduction in energy demand. (author). 95 refs

  18. Key aspects to perform a project on energy management

    International Nuclear Information System (INIS)

    Bachini, R.

    1993-01-01

    A general overview on elements and organisms playing a key role to launch a new industrial project is given, taking as base case an energy management project. Likewise the problematic of training personnel involved in the project is analyzed. Energy management becomes crucial in industries where energy costs represent a big portion of the whole production cost. Main aspects to be analyzed are: - Adequate production procedures to be competitive - Environment protection regarding waste management - Maximization of safety at production installations. (Author)

  19. Money for Research, Not for Energy Bills: Finding Energy and Cost Savings in High Performance Computer Facility Designs

    Energy Technology Data Exchange (ETDEWEB)

    Drewmark Communications; Sartor, Dale; Wilson, Mark

    2010-07-01

    High-performance computing facilities in the United States consume an enormous amount of electricity, cutting into research budgets and challenging public- and private-sector efforts to reduce energy consumption and meet environmental goals. However, these facilities can greatly reduce their energy demand through energy-efficient design of the facility itself. Using a case study of a facility under design, this article discusses strategies and technologies that can be used to help achieve energy reductions.

  20. Anaerobic Digestion Performance in the Energy Recovery of Kiwi Residues

    Science.gov (United States)

    Martins, Ramiro; Boaventura, Rui; Paulista, Larissa

    2017-12-01

    World production and trade of fruits generate losses in the harvest, post-harvest, handling, distribution and consumption phases, corresponding to 6.8% of total production. These residues present high potential as a substrate for the anaerobic digestion process and biogas generation. Thus, the energy valuation of the agro-industrial residues of kiwi production was evaluated by anaerobic digestion, aiming at optimizing the biogas production and its quality. Ten assays were carried out in a batch reactor (500 mL) under mesophilic conditions and varying a number of operational factors: different substrate/inoculum ratios; four distinct values for C: N ratio; inoculum from different digesters; and inoculum collected at different times of the year. The following parameters were used to control and monitor the process: pH, alkalinity, volatile fatty acids (VFA), volatile solids (VS) and chemical oxygen demand (COD). Among the tests performed, the best result obtained for the biogas production corresponded to the use of 2 g of substrate and 98 mL of inoculum of the anaerobic digester of the Wastewater Treatment Plant (WWTP) of Bragança, with addition of 150 mg of bicarbonate leading to a production of 1628 L biogas.kg-1 VS (57% methane). In relation to the biogas quality, the best result was obtained with 20 g of substrate and 380 mL of inoculum from the anaerobic digester sludge of WWTP of Ave (with addition 600 mg of sodium bicarbonate), presenting a value of 85% of CH4, with a production of 464 L biogas.kg-1 VS.

  1. Diversification and Corporate Performance: Evidence from China’s Listed Energy Companies

    Directory of Open Access Journals (Sweden)

    Qiming Li

    2016-09-01

    Full Text Available Recently, China’s energy industry has been continuously depressed due to a slowdown in its economic development. China’s energy companies have made considerable efforts to promote their corporate performance to mitigate this performance decline and to ensure the sustainable development of China’s energy industry, macro economy, society and environment. In this paper, the effects of two business strategies—industrial diversification and international diversification—on the performance of listed energy firms are empirically investigated. The empirical results show the following: (1 industrial diversification hinders corporate performance; (2 for industrially-diversified energy companies, related diversified strategies are more effective than unrelated diversified strategies; and (3 international diversification improves the performance of renewable energy firms, but hinders the performance of conventional energy firms. These results suggest that as economic conditions are not currently optimal, China’s energy companies should pay more attention to their main businesses and generate more products to satisfy market demand.

  2. Whole building energy performance anomaly detection at TU/e

    NARCIS (Netherlands)

    Hensen, J.L.M.; Bynum, J.D.

    2013-01-01

    Existing buildings account for the majority of energy consumption in the building sector. Surveys of existing buildings have found an estimated 10-20% reduction in energy consumption may be feasible. Research at the Eindhoven University of Technology (TU/e) is seeking to realize this potential in

  3. Performance Limitations in High-Energy Ion Colliders

    CERN Document Server

    Fischer, Wolfram

    2005-01-01

    High-energy ion colliders (hadron colliders operating with species other than protons) are premier research tools for nuclear physics. The collision energy and high luminosity are important design and operations considerations. However, the experiments also expect flexibility with frequent changes in the collision energy, lattice configuration, and ion species, including asymmetric collisions. For the creation, acceleration, and storage of bright intense ion beams, attention must be paid to space charge, charge exchange, and intra-beam scattering effects. The latter leads to luminosity lifetimes of only a few hours for heavy ions. Ultimately cooling at full energy is needed to overcome this effect. Currently, the Relativistic Heavy Ion Collider at BNL is the only operating high-energy ion collider. The Large Hadron Collider, under construction at CERN, will also run with heavy ions.

  4. Measuring energy security performance within China: Toward an inter-provincial prospective

    International Nuclear Information System (INIS)

    Zhang, Long; Yu, Jing; Sovacool, Benjamin K.; Ren, Jingzheng

    2017-01-01

    China has been the world's largest energy consumer and producer for many years, yet while myriad studies have investigated Chinese performance on energy metrics compared to other countries, few to none have looked internally at Chinese provinces. This paper firstly develops a five-dimensional evaluation system centered on the energy security dimensions of availability and diversity, affordability and equality, technology and efficiency, environmental sustainability, and governance and innovation. It then correlates these dimensions to 20 distinct energy security metrics that are used to assess the energy security performance of 30 Chinese provinces, divided into eight regions. Our results reveal both trends in energy policy and practice as well as provincial status of comparative energy security for the year 2013. We find, for instance, that there is no province which performs well in all five of the energy security dimensions, and that all provinces confronted threats related to energy availability and diversity. We also demonstrate that in comparative terms, the Middle Reaches of Yellow River and the Northwest were the most energy-secure, while the Middle Reaches of Yangtze River and the Northeast were least energy-secure. - Highlights: • We assessed energy security for 30 Chinese provinces across five dimensions. • Fuzzy AHP, PROMETHEE and Sensitivity Analysis are used to investigate. • Western provinces perform better performance than eastern provinces in 2013. • Energy availability and diversity is the most severe threat facing China's energy security. • Developing renewable energy will help improve China's Provincial energy security significantly.

  5. Investor Reaction to Mandatory Offers on the Warsaw Stock Exchange

    Directory of Open Access Journals (Sweden)

    Szymon Okoń

    2012-06-01

    Full Text Available The following paper aims to assess investor reaction to mandatory offers on the Warsaw Stock Exchange, which is important because knowledge about these reactions can be used to make better investment decisions. This paper highlights the importance of procedure in making a mandatory offer and its grounds in the Polish legal system. Additionally, it presents empirical research on the reactions of investors to mandatory offers on the Warsaw Stock Exchange. It has been provided that mandatory offers have a significant impact on the price of a company’s shares listed on the Warsaw Stock Exchange. Knowledge about the reactions of investors to a mandatory offer may be used when selecting securities for an investment portfolio. The findings may provide guidance in deciding whether to begin or end investment in the company, both for individual and institutional investors. The event study methodology approach used in the paper is regarded as valuable and can be the basis for further research in other areas of the capital market research, especially in the context of information efficiency.

  6. Energy Resources Performance Report, FY 1991 and FY 1992.

    Energy Technology Data Exchange (ETDEWEB)

    United States. Bonneville Power Administration.

    1993-07-01

    Once the Federal Columbia River Power System provided all the power our customers needed and surplus energy, which we sold to others. However, we planned for the time when the surplus would disappear. With our customers, we developed centralized, region-wide conservation programs to conserve energy and build the knowledge and ability to save more energy when needed. We began to look at conservation as a resource, comparing it with supply-side alternatives. Much was accomplished. In Bonneville`s service area in the 1980s, our customers acquired 300 average megawatts (aMW) of conservation savings. How? By weatherizing about 240,000 homes, by making aluminum plants, other industrial plants and commercial buildings more efficient, and also by encouraging states to adopt energy-efficient building codes. Now, our energy surplus is gone. Our customers need energy, and in a hurry. While we plan how much energy will be needed, when and by which customers, we must concurrently accelerate our efforts to acquire resources. Our 1990 Resource Program launched a strategy to do just that, starting in 1991 and 1992, with continuing activities in 1993--1995. The goals and plans of the 1990 Resource Program are still being implemented.

  7. Perspectives of energy efficient technologies penetration in the Greek domestic sector, through the analysis of Energy Performance Certificates

    International Nuclear Information System (INIS)

    Gelegenis, J.; Diakoulaki, D.; Lampropoulou, H.; Giannakidis, G.; Samarakou, M.; Plytas, N.

    2014-01-01

    The building sector in Greece presents a huge energy saving potential, the largest part of which is remaining unexploited. The recently enacted legislation for the energy performance of buildings, in combination with the financial support provided by funding programmes to low income families is expected to significantly boost the deployment of energy efficient technologies in the Greek domestic sector. The exploitation of these legal and financial instruments follows a formalised process of energy audits, resulting in buildings classification and in the submission of Energy Performance Certificates (EPCs) including suggestions to improve the dwellings' energy performance. The paper aims at an ex-ante evaluation of the market trends revealed by EPCs in Greece, in order to identify the perspectives of individual technologies and to assess the degree to which the certification procedure helps in improving the energy performance of buildings. The results indicate a strong trend towards less cost-effective technologies, revealing a sub-optimal allocation of financial resources and putting into risk the path towards the achievement of EU targets for 2020. - Highlights: • Energy Performance Certificates reveal market trends of energy efficient technologies. • SWH, replacement of windows and walls/roof insulation are most often recommended. • Other measures are controls, switch to NG; low cost measures are rarely recommended. • Cost-effectiveness is not the main factor explaining technology recommendations. • Amendment of EPC document and inspection process may enhance its effectiveness

  8. Application of Partial Safety Factorsin Building Energy Performance Assessment

    DEFF Research Database (Denmark)

    Brohus, Henrik; Heiselberg, Per; Hesselholt, A.

    2009-01-01

    is evaluated by sensitivity and uncertainty analysis to develop a significantly reduced set of stochastic input parameters. The safety factor approach provides a means of enforcing the maximum allowed energy consumption in the building code by multiplying the maximum limit by a partial safety factor to obtain......In practise many buildings show significant deviation between the predicted annual energy consumption and the actual energy consumption. One of the main reasons for the discrepancy is the difference between the assumptions made during the calculations and the actual conditions including occupants...

  9. Window Energy Rating System and Calculation of Energy Performance of Windows

    DEFF Research Database (Denmark)

    Laustsen, Jacob Birck; Svendsen, Svend

    The goal of reducing the energy consumption in buildings is the background for the introduction of an energy rating system of fenestration products in Denmark. The energy rating system requires that producers declare, among other things, the heat loss coefficient, U, and the total solar energy...... development, e.g. when the resulting effects of a reduced frame area are evaluated....

  10. Local Alternative for Energy Supply : Performance Assessment of Integrated Community Energy Systems

    NARCIS (Netherlands)

    Koirala, B.P.; Chaves Avila, J.P.; Gomez, T.; Hakvoort, R.A.; Herder, P.M.

    2016-01-01

    Integrated community energy systems (ICESs) are emerging as a modern development to re-organize local energy systems allowing simultaneous integration of distributed energy resources (DERs) and engagement of local communities. Although local energy initiatives, such as ICESs are rapidly emerging due

  11. Performance profiles of major energy producers 1995, January 1997

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-02-01

    This publication examines developments in the operations of the major U.S. energy-producing companies on a corporate level, by major line of business, by major function within each line of business, and by geographic area.

  12. Performance Study of Diagonally Segmented Piezoelectric Vibration Energy Harvester

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jae Eun [Catholic Univ. of Daegu, Daegu (Korea, Republic of)

    2013-08-15

    This study proposes a piezoelectric vibration energy harvester composed of two diagonally segmented energy harvesting units. An auxiliary structural unit is attached to the tip of a host structural unit cantilevered to a vibrating base, where the two components have beam axes in opposite directions from each other and matched short-circuit resonant frequencies. Contrary to the usual observations in two resonant frequency-matched structures, the proposed structure shows little eigenfrequency separation and yields a mode sequence change between the first two modes. These lead to maximum power generation around a specific frequency. By using commercial finite element software, it is shown that the magnitude of the output power from the proposed vibration energy harvester can be substantially improved in comparison with those from conventional cantilevered energy harvesters with the same footprint area and magnitude of a tip mass.

  13. Energy performance of Portuguese and Danish wood-burning stoves

    DEFF Research Database (Denmark)

    Carvalho, Ricardo; Jensen, Ole Michael; Tarelho, Luis A. C.

    2011-01-01

    In Europe, considerable amounts of renewable energy resources are used for residential heating with wood-burning stoves, which can cause considerable energy losses and environmental impacts. A better understanding of its operating characteristics will permit to improve the buildings energy...... carried out through the measurement of the main operating parameters: flue gas temperature and composition, combustion air flow rate, and fuel consumption rate. The results showed that the appliances emitted energy intermittently, with a mean heat flow rate into the indoors of 5 kWth, representing mean...... efficiency and indoor climate, and to reduce the emission of air pollutants to the environment. This study aimed to analyze the operating conditions of a Portuguese made stove and compare it with the most efficient Danish made stoves tested at the Technological Institute. The combustion experiments were...

  14. Contrasting the capabilities of building energy performance simulation programs

    Energy Technology Data Exchange (ETDEWEB)

    Crawley, Drury B. [US Department of Energy, Washington, DC (United States); Hand, Jon W. [University of Strathclyde, Glasgow, Scotland (United Kingdom). Energy Systems Research Unit; Kummert, Michael [University of Wisconsin-Madison (United States). Solar Energy Laboratory; Griffith, Brent T. [National Renewable Energy Laboratory, Golden, CO (United States)

    2008-04-15

    For the past 50 years, a wide variety of building energy simulation programs have been developed, enhanced and are in use throughout the building energy community. This paper is an overview of a report, which provides up-to-date comparison of the features and capabilities of twenty major building energy simulation programs. The comparison is based on information provided by the program developers in the following categories: general modeling features; zone loads; building envelope and daylighting and solar; infiltration, ventilation and multizone airflow; renewable energy systems; electrical systems and equipment; HVAC systems; HVAC equipment; environmental emissions; economic evaluation; climate data availability, results reporting; validation; and user interface, links to other programs, and availability. (author)

  15. Performance profiles of major energy producers 1995, January 1997

    International Nuclear Information System (INIS)

    1997-01-01

    This publication examines developments in the operations of the major U.S. energy-producing companies on a corporate level, by major line of business, by major function within each line of business, and by geographic area

  16. Should Lecture Recordings Be Mandated in Dental Schools? Two Viewpoints: Viewpoint 1: Lecture Recordings Should Be Mandatory in U.S. Dental Schools and Viewpoint 2: Lecture Recordings Should Not Be Mandatory in U.S. Dental Schools.

    Science.gov (United States)

    Zandona, Andrea Ferreira; Kinney, Janet; Seong, WookJin; Kumar, Vandana; Bendayan, Alexander; Hewlett, Edmond

    2016-12-01

    Transcription or recording of lectures has been in use for many years, and with the availability of high-fidelity recording, the practice is now ubiquitous in higher education. Since technology has permeated education and today's tech-savvy students have expectations for on-demand learning, dental schools are motivated to record lectures, albeit with positive and negative implications. This Point/Counterpoint article addresses the question of whether lecture recording should be mandatory in U.S. dental schools. Viewpoint 1 supports the statement that lecture recording should be mandatory. Proponents of this viewpoint argue that the benefits-notably, student satisfaction and potential for improvement in student performance-outweigh concerns. Viewpoint 2 takes the opposite position, arguing that lecture recording decreases students' classroom attendance and adversely affects the morale of educators. Additional arguments against mandatory lecture recordings involve the expense of incorporating technology that requires ongoing support.

  17. Energy Performance Certificate of building and confidence interval in assessment: An Italian case study

    International Nuclear Information System (INIS)

    Tronchin, Lamberto; Fabbri, Kristian

    2012-01-01

    The Directive 2002/91/CE introduced the Energy Performance Certificate (EPC), an energy policy tool. The aim of the EPC is to inform building buyers about the energy performance and energy costs of buildings. The EPCs represent a specific energy policy tool to orient the building sector and real-estate markets toward higher energy efficiency buildings. The effectiveness of the EPC depends on two factors: •The accuracy of energy performance evaluation made by independent experts. •The capability of the energy classification and of the scale of energy performance to control the energy index fluctuations. In this paper, the results of a case study located in Italy are shown. In this example, 162 independent technicians on energy performance of building evaluation have studied the same building. The results reveal which part of confidence intervals is dependent on software misunderstanding and that the energy classification ranges are able to tolerate the fluctuation of energy indices. The example was chosen in accordance with the legislation of the Emilia-Romagna Region on Energy Efficiency of Buildings. Following these results, some thermo-economic evaluation related to building and energy labelling are illustrated, as the EPC, which is an energy policy tool for the real-estate market and building sector to find a way to build or retrofit an energy efficiency building. - Highlights: ► Evaluation of the accuracy of energy performance of buildings in relation with the knowledge of independent experts. ► Round robin test based on 162 case studies on the confidence intervals expressed by independent experts. ► Statistical considerations between the confidence intervals expressed by independent experts and energy simulation software. ► Relation between “proper class” in energy classification of buildings and confidence intervals of independent experts.

  18. Job-specific mandatory medical examinations for the police force.

    Science.gov (United States)

    Boschman, J S; Hulshof, C T J; Frings-Dresen, M H W; Sluiter, J K

    2017-08-01

    Mandatory medical examinations (MMEs) of workers should be based on the health and safety requirements that are needed for effectively performing the relevant work. For police personnel in the Netherlands, no job-specific MME exists that takes the specific tasks and duties into account. To provide the Dutch National Police with a knowledge base for job-specific MMEs for police personnel that will lead to equitable decisions from an occupational health perspective about who can perform police duties. We used a stepwise mixed-methods approach in which we included interviews with employees and experts and a review of the national and international literature. We determined the job demands for the various police jobs, determined which were regarded as specific job demands and formulated the matching health requirements as specific as possible for each occupation. A total of 21 specific job demands were considered relevant in different police jobs. These included biomechanical, physiological, physical, emotional, psychological/cognitive and sensory job demands. We formulated both police-generic and job-specific health requirements based on the specific job demands. Two examples are presented: bike patrol and criminal investigation. Our study substantiated the need for job-specific MMEs for police personnel. We found specific job demands that differed substantially for various police jobs. The corresponding health requirements were partly police-generic, and partly job-specific. © The Author 2017. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com

  19. EVALUATION OF ENERGY PERFORMANCE USING DOE-2 ENERGY SIMULATION PROGRAM IN SINGAPORE

    Directory of Open Access Journals (Sweden)

    Po Seng Kian

    2000-01-01

    Full Text Available Recently, due to worldwide energy cost rising significantly, there has been an essential need to minimize the energy consumption. This global warning address many countries including Singapore realizing the important of energy efficiency in industries and buildings. This paper deals with analyzing the energy consumption of an 11-storey commercial building in Singapore using DOE-2 Energy Simulation Program. A study is made on the benefits derived from modifying the building envelope, space system setting, air-conditioning plant, and lighting. This encompasses a description of its quantitative impact on cooling load, energy consumption and energy saving achieved as compared with the original building. Following this, a life cycle costing is done to determine the economic benefits attained from this modification. This study shows that some alternative solutions can be achieved using energy simulation program to conserve the energy consumption.

  20. High energy-density liquid rocket fuel performance

    Science.gov (United States)

    Rapp, Douglas C.

    1990-01-01

    A fuel performance database of liquid hydrocarbons and aluminum-hydrocarbon fuels was compiled using engine parametrics from the Space Transportation Engine Program as a baseline. Propellant performance parameters are introduced. General hydrocarbon fuel performance trends are discussed with respect to hydrogen-to-carbon ratio and heat of formation. Aluminum-hydrocarbon fuel performance is discussed with respect to aluminum metal loading. Hydrocarbon and aluminum-hydrocarbon fuel performance is presented with respect to fuel density, specific impulse and propellant density specific impulse.

  1. Market performance and distributional effects on renewable energy markets

    International Nuclear Information System (INIS)

    Koutstaal, P.; Bijlsma, M.; Zwart, G.; Van Tilburg, X.; Ozdemir, O.

    2009-08-01

    A renewable obligation (RO) combined with tradable renewable energy certificates is a market-based instrument used to promote the production of electricity from renewable energy sources. A renewable obligation is an alternative for subsidies. A renewable obligation will only be an efficient instrument if certificate markets are efficient. This requires that there is no market power and no anti-competitive behaviour on the certificate market. If the current developments in Dutch renewable energy production continue, market power on a future renewable certificate market in the Netherlands will probably not be an issue, even if the RO should only rest on the retail market instead of on the whole electricity market. A renewable obligation will raise the retail price for consumers, thereby reducing consumer surplus. Simulations show that the retail electricity price increases with 30 euro per MWh to a level of 104 euro per MWh in case of a 30% renewable target. Consumer surplus is reduced with 19% compared to the baseline scenario. In contrast, a subsidy such as the Dutch SDE (Promoting Renewable Energy scheme or 'Stimulering Duurzame Energie') which is financed from the state budget has the effect to (slightly) lower the retail electricity price, thereby increasing consumer surplus. It should however be realised that the costs of the subsidy will indirectly affect electricity consumers through their tax payments.

  2. Voluntary CSR vs. mandatory CSR : the sound of employees

    OpenAIRE

    Sarna, Bhavesh

    2016-01-01

    Corporate Social Responsibility (CSR) laws are an area of exploration and there is debate over preference to voluntary CSR laws or to mandatory CSR laws. The objective is to con-duct a micro-level study to explore the employee’s preferences for mandatory CSR laws or voluntary CSR laws. There is some existing literature on this topic at the macro-level and goal is to extend and contribute to the literature about this topic by studying the pref-erence at the micro-level. A qualitative study bas...

  3. Cloud computing platform for real-time measurement and verification of energy performance

    International Nuclear Information System (INIS)

    Ke, Ming-Tsun; Yeh, Chia-Hung; Su, Cheng-Jie

    2017-01-01

    Highlights: • Application of PSO algorithm can improve the accuracy of the baseline model. • M&V cloud platform automatically calculates energy performance. • M&V cloud platform can be applied in all energy conservation measures. • Real-time operational performance can be monitored through the proposed platform. • M&V cloud platform facilitates the development of EE programs and ESCO industries. - Abstract: Nations worldwide are vigorously promoting policies to improve energy efficiency. The use of measurement and verification (M&V) procedures to quantify energy performance is an essential topic in this field. Currently, energy performance M&V is accomplished via a combination of short-term on-site measurements and engineering calculations. This requires extensive amounts of time and labor and can result in a discrepancy between actual energy savings and calculated results. In addition, the M&V period typically lasts for periods as long as several months or up to a year, the failure to immediately detect abnormal energy performance not only decreases energy performance, results in the inability to make timely correction, and misses the best opportunity to adjust or repair equipment and systems. In this study, a cloud computing platform for the real-time M&V of energy performance is developed. On this platform, particle swarm optimization and multivariate regression analysis are used to construct accurate baseline models. Instantaneous and automatic calculations of the energy performance and access to long-term, cumulative information about the energy performance are provided via a feature that allows direct uploads of the energy consumption data. Finally, the feasibility of this real-time M&V cloud platform is tested for a case study involving improvements to a cold storage system in a hypermarket. Cloud computing platform for real-time energy performance M&V is applicable to any industry and energy conservation measure. With the M&V cloud platform, real

  4. Measuring energy performance with sectoral heterogeneity: A non-parametric frontier approach

    International Nuclear Information System (INIS)

    Wang, H.; Ang, B.W.; Wang, Q.W.; Zhou, P.

    2017-01-01

    Evaluating economy-wide energy performance is an integral part of assessing the effectiveness of a country's energy efficiency policy. Non-parametric frontier approach has been widely used by researchers for such a purpose. This paper proposes an extended non-parametric frontier approach to studying economy-wide energy efficiency and productivity performances by accounting for sectoral heterogeneity. Relevant techniques in index number theory are incorporated to quantify the driving forces behind changes in the economy-wide energy productivity index. The proposed approach facilitates flexible modelling of different sectors' production processes, and helps to examine sectors' impact on the aggregate energy performance. A case study of China's economy-wide energy efficiency and productivity performances in its 11th five-year plan period (2006–2010) is presented. It is found that sectoral heterogeneities in terms of energy performance are significant in China. Meanwhile, China's economy-wide energy productivity increased slightly during the study period, mainly driven by the technical efficiency improvement. A number of other findings have also been reported. - Highlights: • We model economy-wide energy performance by considering sectoral heterogeneity. • The proposed approach can identify sectors' impact on the aggregate energy performance. • Obvious sectoral heterogeneities are identified in evaluating China's energy performance.

  5. Performance and energy efficiency in wireless self-organized networks

    Energy Technology Data Exchange (ETDEWEB)

    Gao, C.

    2009-07-01

    Self-organized packet radio networks (ad-hoc networks) and wireless sensor networks have got massive attention recently. One of critical problems in such networks is the energy efficiency, because wireless nodes are usually powered by battery. Energy efficiency design can dramatically increase the survivability and stability of wireless ad-hoc/sensor networks. In this thesis the energy efficiency has been considered at different protocol layers for wireless ad-hoc/sensor networks. The energy consumption of wireless nodes is inspected at the physical layer and MAC layer. At the network layer, some current routing protocols are compared and special attention has been paid to reactive routing protocols. A minimum hop analysis is given and according to the analysis result, a modification of AODV routing is proposed. A variation of transmit power can be also applied to clustering algorithm, which is believed to be able to control the scalability of network. Clustering a network can also improve the energy efficiency. We offer a clustering scheme based on the link state measurement and variation of transmit power of intra-cluster and inter-cluster transmission. Simulation shows that it can achieve both targets. In association with the clustering algorithm, a global synchronization scheme is proposed to increase the efficiency of clustering algorithm. The research attention has been also paid to self-organization for multi-hop cellular networks. A 2-hop 2-slot uplink proposal to infrastructure-based cellular networks. The proposed solution can significantly increase the throughput of uplink communication and reduce the energy consumption of wireless terminals. (orig.)

  6. 22 CFR 906.2 - Mandatory hearing.

    Science.gov (United States)

    2010-04-01

    ... retirement from the Service for expiration of time-in-class or based on relative performance, or (b) In any case which in the judgment of the Board can best be resolved by a hearing or presentation of oral... employee waives in writing his or her right to such hearing. ...

  7. Energy transition. A complete view on costs, performance, flexibility and prices of energies - Journal nr 11

    International Nuclear Information System (INIS)

    Boncorps, Jean-Claude; Larzilliere, Marc; Bomo, Nicole; Bruder, Michel; Buscailhon, Jean-Marie; Cappe, Daniel; DobiaS, Georges; Fregere, Jean-Pierre; Garipuy, Yves; Hougueres, Gerard; Martin, Jean-Loup; Mollard, Dominique; Moncomble, Jean-Eudes; Wiltz, Bruno; Roudier, Jacques

    2013-02-01

    This publication aims at proposing information on the issues of energy prices, of energy production costs and of energy delivery costs, and at showing their complexity while clearing up some wrong ideas about them. After an introduction on the addressed problematic, on information sources and on uncertainties, the authors give a general overview of the definitions of a cost, of a price, of primary, secondary and final energies, of user diversity and energy demand variation in time, of energy production variations in time, and present energy taxing in France and in the European Union, the CO 2 market, and energy savings in France in various sectors (transports, buildings, industry). Then, they address the various primary energies (coal, oil, natural gas, biomass, geothermal heat, thermal solar) and secondary energies (nuclear, hydroelectricity, ground-based wind energy, renewable sea energies, geothermal electricity, electricity grids, heat networks and co-generation) and discuss for each or some of them issues like: world market, costs and pricing, perspectives, resources and constraints, technologies

  8. Air Tightness and Energy Performance of an Arctic Low-Energy House

    DEFF Research Database (Denmark)

    Rode, Carsten; Vladyková, Petra; Kotol, Martin

    2010-01-01

    A low-energy house has been built in Sisimiut, Greenland, five years ago. An ambitious target was set for its low energy consumption for heating: 80 kWh/(m2∙a). But unfortunately, the house has used more energy than planned, approximately 140 kWh/(m2∙a). Although higher than anticipated, this is ...

  9. Energy Design Guidelines for High Performance Schools: Arctic and Subarctic Climates

    Energy Technology Data Exchange (ETDEWEB)

    2004-11-01

    The Energy Design Guidelines for High Performance Schools--Arctic and Subarctic Climates provides school boards, administrators, and design staff with guidance to help them make informed decisions about energy and environmental issues important to school systems and communities. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school in arctic and subarctic climates. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs.

  10. Energy key performance indicators : a european benchmark and assessment of meaningful indicators for the use of energy in large corporations

    OpenAIRE

    Friedrichs, Katja

    2013-01-01

    This study aims to identify and analyze energy key performance indicators among large European companies. Energy usage has become a very meaningful topic for both internal management as well as external stakeholders of a company. A review of current literature suggests that while environmental indicators in general have found broad attention and plenty of theories concerning good and meaningful indicators are published, no study investigating actually applied energy indicators ...

  11. Energy Consumption Performance Analysis of Electrical Mitad at ...

    African Journals Online (AJOL)

    Bheema

    The household sector in Ethiopia accounts for about 89% of the total energy ... subsequently contribute for the economic development of the country. ...... The Authors would like to thank the EnPe project (EnPe 2009-2014) of School of ...

  12. Energy performance assessment of Looe junior and infant school

    Energy Technology Data Exchange (ETDEWEB)

    Alexander, D.K.; Vaughan, N.D.; Jenkins, H.G. (Welsh School of Architecture, Cardiff (GB)); O' Sullivan, P.E. (University Coll., London (GB). Bartlett School of Architecture and Planning)

    1990-01-01

    A multi-disciplinary appraisal of a passive solar primary school in Cornwall is presented. The building was found to be energy efficient and well liked by the teaching staff. Whilst problems were noted in ventilation control and air-quality the building was considered to be a successful example of passive solar design. (author).

  13. Research of performance prediction to energy on hydraulic turbine

    International Nuclear Information System (INIS)

    Quan, H; Li, R N; Li, Q F; Han, W; Su, Q M

    2012-01-01

    Refer to the low specific speed Francis turbine blade design principle and double-suction pump structure. Then, design a horizontal double-channel hydraulic turbine Francis. Through adding different guide vane airfoil and and no guide vane airfoil on the hydraulic conductivity components to predict hydraulic turbine energy and using Fluent software to numerical simulation that the operating conditions and point. The results show that the blade pressure surface and suction surface pressure is low when the hydraulic turbine installation is added standard positive curvature of the guide vane and modified positive curvature of guide vane. Therefore, the efficiency of energy recovery is low. However, the pressure of negative curvature guide vane and symmetric guide vane added on hydraulic turbine installations is larger than that of the former ones, and it is conducive to working of runner. With the decreasing of guide vane opening, increasing of inlet angle, flow state gets significantly worse. Then, others obvious phenomena are that the reflux and horizontal flow appeared in blade pressure surface. At the same time, the vortex was formed in Leaf Road, leading to the loss of energy. Through analyzing the distribution of pressure, velocity, flow lines of over-current flow in the the back hydraulic conductivity components in above programs we can known that the hydraulic turbine installation added guide vane is more reasonable than without guide vanes, it is conducive to improve efficiency of energy conversion.

  14. Performance of Jets and Missing Transverse Energy in ATLAS

    CERN Document Server

    Schwartzman, A; The ATLAS collaboration

    2013-01-01

    After the analysis of the 2010 proton proton collision data provided by LHC, the ATLAS experiment has achieved an accuracy of the jet energy measurement between 2-4\\% for jet transverse momenta from $20$ GeV to about $2$ TeV in the pseudo-rapidity range up to $|\\eta|=4.5$. The jet energy scale uncertainty is derived from in-situ single hadron response measurements along with systematic variations in the Monte Carlo simulation. In addition, several in situ techniques exploiting transverse momentum balance are exploited. Preliminary results from the 2011 run based on an integrated luminosity of $5$ fb reducing further the uncertainties on the jet energy scale are presented. Results on the energy scale and resolution of the reconstructed missing transverse momentum (ETmis) from 2010 and 2011 collision data are also presented. The uncertainty evaluation mainly relies on events with a Z-boson. Special attention is given to the influence of the large number of interactions produced in addition to the event of inter...

  15. Advanced Energy Retrofit Guide: Practical Ways to Improve Energy Performance; Grocery Stores (Revised) (Book)

    Energy Technology Data Exchange (ETDEWEB)

    Hendron, B.

    2013-07-01

    The U.S. Department of Energy developed the Advanced Energy Retrofit Guides (AERGs) to provide specific methodologies, information, and guidance to help energy managers and other stakeholders successfully plan and execute energy efficiency improvements. Detailed technical discussion is fairly limited in these guides. Instead, we emphasize actionable information, practical methodologies, diverse case studies, and unbiased evaluations of the most promising retrofit measures for each building type. A series of AERGs is under development, addressing key segments of the commercial building stock. Grocery stores were selected as one of the highest priority sectors, because they represent one of the most energy-intensive market segments.

  16. Energy Consumption and Indoor Environment Predicted by a Combination of Computational Fluid Dynamics and Building Energy Performance Simulation

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm

    2003-01-01

    An interconnection between a building energy performance simulation program and a Computational Fluid Dynamics program (CFD) for room air distribution is introduced for improvement of the predictions of both the energy consumption and the indoor environment.The article describes a calculation...

  17. Evaluation of the Energy and Comfort Performance of a Plus-Energy House under Scandinavian Summer Conditions

    DEFF Research Database (Denmark)

    Pean, Thibault Quentin; Gennari, Luca; Kazanci, Ongun Berk

    2016-01-01

    The thermal indoor environment and the energy performance of a plus-energy house are evaluated in the present study. The study case is EMBRACE, a two-storey dwelling of 59 m2 designed to host a single family. The building includes a semi-outdoor space covered by a glazed envelope, where the therm...

  18. Using intelligent clustering techniques to classify the energy performance of school buildings

    Energy Technology Data Exchange (ETDEWEB)

    Santamouris, M.; Sfakianaki, K.; Papaglastra, M.; Pavlou, C.; Doukas, P.; Geros, V.; Assimakopoulos, M.N.; Zerefos, S. [University of Athens, Department of Physics, Division of Applied Physics, Laboratory of Meteorology, Athens (Greece); Mihalakakou, G.; Gaitani, N. [University of Ioannina, Department of Environmental and Natural Resources Management, Agrinio (Greece); Patargias, P. [University of Peloponnesus, Faculty of Human Sciences and Cultural Studies, Department of History, Kalamata (Greece); Primikiri, E. [University of Patras, Department of Architecture, Patras (Greece); Mitoula, R. [Charokopion University of Athens, Athens (Greece)

    2007-07-01

    The present paper deals with the energy performance, energy classification and rating and the global environmental quality of school buildings. A new energy classification technique based on intelligent clustering methodologies is proposed. Energy rating of school buildings provides specific information on their energy consumption and efficiency relative to the other buildings of similar nature and permits a better planning of interventions to improve its energy performance. The overall work reported in the present paper, is carried out in three phases. During the first phase energy consumption data have been collected through energy surveys performed in 320 schools in Greece. In the second phase an innovative energy rating scheme based on fuzzy clustering techniques has been developed, while in the third phase, 10 schools have been selected and detailed measurements of their energy efficiency and performance as well as of the global environmental quality have been performed using a specific experimental protocol. The proposed energy rating method has been applied while the main environmental and energy problems have been identified. The potential for energy and environmental improvements has been assessed. (author)

  19. Measuring economy-wide energy efficiency performance: A parametric frontier approach

    International Nuclear Information System (INIS)

    Zhou, P.; Ang, B.W.; Zhou, D.Q.

    2012-01-01

    This paper proposes a parametric frontier approach to estimating economy-wide energy efficiency performance from a production efficiency point of view. It uses the Shephard energy distance function to define an energy efficiency index and adopts the stochastic frontier analysis technique to estimate the index. A case study of measuring the economy-wide energy efficiency performance of a sample of OECD countries using the proposed approach is presented. It is found that the proposed parametric frontier approach has higher discriminating power in energy efficiency performance measurement compared to its nonparametric frontier counterparts.

  20. British surgeons' experiences of mandatory online workplace-based assessment.

    Science.gov (United States)

    Pereira, Erlick A C; Dean, Benjamin J F

    2009-07-01

    An online workplace-based assessment tool, the Intercollegiate Surgical Curriculum Programme (ISCP), has become mandatory for all British surgical trainees appointed since August 2007. A compulsory pound125 annual trainee fee has also been introduced to fund its running costs. The study sought to evaluate user satisfaction with the ISCP. A total of 539 users across all surgical specialties (including 122 surgeons acting as assessors) were surveyed in late 2008 by online questionnaire regarding their experiences with the ISCP. Sixty-seven percent had used the tool for at least one year. It was rated above average by only 6% for its registration process and only 11% for recording meetings and objectives. Forty-nine percent described its online assessments as poor or very poor, only 9% considering them good or very good. Seventy-nine percent rated the website's user friendliness as average or worse, as did 72% its peer-assessment tool and 61% its logbook of procedures. Seventy-six percent of respondents had carried out paper assessments due to difficulties using the website. Six percent stated that the ISCP had impacted negatively on their training opportunities, 41% reporting a negative impact overall upon their training; only 6% reported a positive impact. Ninety-four percent did not consider the trainee fee good value, only 2% believing it should be paid by the trainee. The performance of the ISCP leaves large numbers of British surgeons unsatisfied. Its assessments lack appropriate evidence of validity and its introduction has been problematic. With reducing training hours, the increased online bureaucratic burden exacerbates low morale of trainees and trainers, adversely impacting potentially upon both competency and productivity.

  1. Unintended anchors: Building rating systems and energy performance goals for U.S. buildings

    International Nuclear Information System (INIS)

    Klotz, Leidy; Mack, Daniel; Klapthor, Brent; Tunstall, Casey; Harrison, Jennilee

    2010-01-01

    In the U.S., where buildings account for 40% of energy use, commercial buildings use more energy per unit area than ever before. However, exemplary buildings demonstrate the feasibility of much better energy performance at no additional first cost. This research examines one possible explanation for this inconsistency. The aim is to investigate whether the anchoring bias, which refers to our tendency to gravitate towards a pre-defined standard regardless of its relevance, influences energy performance goals in building design. The scope examines professionals who help set energy performance goals for U.S. buildings. Prior to being asked to set an energy performance goal, these professionals were randomly directed to one of three series of questions. One series set an anchor of 90% energy reduction beyond standard practice, one set a 30% anchor, and one set no anchor. Respondents exposed to the 90% anchor, and respondents exposed to no anchor at all, set higher energy performance goals than respondents exposed to the 30% anchor. These results suggest that building rating systems that only reward incremental energy improvements may inadvertently create anchors, thereby discouraging more advanced energy performance goals and inhibiting energy performance that is technically and economically feasible.

  2. Assessing the Costs and Benefits of the Superior Energy Performance Program

    Energy Technology Data Exchange (ETDEWEB)

    Therkelsen, Peter; McKane, Aimee; Sabouini, Ridah; Evans, Tracy

    2013-07-01

    Industrial companies are seeking to manage energy consumption and costs, mitigate risks associated with energy, and introduce transparency into reports of their energy performance achievements. Forty industrial facilities are participating in the U.S. DOE supported Superior Energy Performance (SEP) program in which facilities implement an energy management system based on the ISO 50001 standard, and pursue third-party verification of their energy performance improvements. SEP certification provides industrial facilities recognition for implementing a consistent, rigorous, internationally recognized business process for continually improving energy performance and achievement of established energy performance improvement targets. This paper focuses on the business value of SEP and ISO 50001, providing an assessment of the costs and benefits associated with SEP implementation at nine SEP-certified facilities across a variety of industrial sectors. These cost-benefit analyses are part of the U.S. DOE?s contribution to the Global Superior Energy Performance (GSEP) partnership, a multi-country effort to demonstrate, using facility data, that energy management system implementation enables companies to improve their energy performance with a greater return on investment than business-as-usual (BAU) activity. To examine the business value of SEP certification, interviews were conducted with SEP-certified facilities. The costs of implementing the SEP program, including internal facility staff time, are described and a marginal payback of SEP certification has been determined. Additionally, more qualitative factors with regard to the business value and challenges related to SEP and ISO 50001 implementation are summarized.

  3. Energy-efficient houses built according to the energy performance requirements introduced in Denmark in 2006

    DEFF Research Database (Denmark)

    Tommerup, Henrik M.; Rose, Jørgen; Svendsen, Svend

    2007-01-01

    In order to meet new tighter building energy requirements introduced in Denmark in 2006 and prepare the way for future buildings with even lower energy consumption, single-family houses were built with the purpose to demonstrate that it is possible to build typical single-family houses with an en......% of the required and almost the level of typical passive houses.......In order to meet new tighter building energy requirements introduced in Denmark in 2006 and prepare the way for future buildings with even lower energy consumption, single-family houses were built with the purpose to demonstrate that it is possible to build typical single-family houses...... with an energy consumption that meets the demands without problems concerning building technology or economy. The paper gives a brief presentation of the houses and the applied energy-saving measures. The paper also presents results from measurements of the overall energy use, indoor climate and air tightness...

  4. Mandatory Rest Stops Improve Athlete Safety during Event Medical Coverage for Ultramarathons.

    Science.gov (United States)

    Joslin, Jeremy; Mularella, Joshua; Bail, Allison; Wojcik, Susan; Cooney, Derek R

    2016-02-01

    Provisions of medical direction and clinical services for ultramarathons require specific attention to heat illness. Heat stress can affect athlete performance negatively, and heat accumulation without acclimatization is associated with the development of exertional heat stroke (EHS). In order to potentially mitigate the risk of this safety concern, the Jungle Marathon (Para, Brazil) instituted mandatory rest periods during the first two days of this 7-day, staged, Brazilian ultramarathon. Race records were reviewed retrospectively to determine the number of runners that suffered an emergency medical complication related to heat stress and did not finish (DNF) the race. Review of records included three years before and three years after the institution of these mandatory rest periods. A total of 326 runners competed in the Jungle Marathon during the 2008-2013 period of study. During the pre-intervention years, a total of 46 athletes (21%) DNF the full race with 25 (54.3%) cases attributed to heat-related factors. During the post-intervention years, a total of 26 athletes (24.3%) DNF the full race with four (15.4%) cases attributed to heat-related factors. Mandatory rest stops during extreme running events in hot or tropical environments, like the Jungle Marathon, are likely to improve athlete safety and improve the heat acclimatization process.

  5. Highlighting High Performance: National Renewable Energy Laboratory's Visitors Center, Golden, Colorado

    International Nuclear Information System (INIS)

    Burgert, S.

    2001-01-01

    The National Renewable Energy Laboratory Visitors Center, also known as the Dan Schaefer Federal Building, is a high-performance building located in Golden, Colorado. The 6,400-square-foot building incorporates passive solar heating, energy-efficient lighting, an evaporative cooling system, and other technologies to minimize energy costs and environmental impact. The Visitors Center displays a variety of interactive exhibits on energy efficiency and renewable energy, and the building includes an auditorium, a public reading room, and office space

  6. Performance analysis of an integrated energy storage and energy upgrade thermochemical solid–gas sorption system for seasonal storage of solar thermal energy

    International Nuclear Information System (INIS)

    Li, Tingxian; Wang, Ruzhu; Kiplagat, Jeremiah K.; Kang, YongTae

    2013-01-01

    An innovative dual-mode thermochemical sorption energy storage method is proposed for seasonal storage of solar thermal energy with little heat losses. During the charging phase in summer, solar thermal energy is stored in form of chemical bonds resulting from thermochemical decomposition process, which enables the stored energy to be kept several months at ambient temperature. During the discharging phase in winter, the stored thermal energy is released in the form of chemical reaction heat resulting from thermochemical synthesis process. Thermodynamic analysis showed that the advanced dual-mode thermochemical sorption energy storage is an effective method for the long-term seasonal storage of solar energy. A coefficient of performance (COP h ) of 0.6 and energy density higher than 1000 kJ/kg of salt can be attained from the proposed system. During the discharging phase at low ambient temperatures, the stored thermal energy can be upgraded by use of a solid–gas thermochemical sorption heat transformer cycle. The proposed thermochemical sorption energy storage has distinct advantages over the conventional sensible heat and latent heat storage, such as higher energy storage density, little heat losses, integrated energy storage and energy upgrade, and thus it can contribute to improve the seasonal utilization of solar thermal energy. - Highlights: ► A dual-mode solid thermochemical sorption is proposed for seasonal solar thermal energy storage. ► Energy upgrade techniques into the energy storage system are integrated. ► Performance of the proposed seasonal energy storage system is evaluated. ► Energy density and COP h from the proposed system are as high as 1043 kJ/kg of salt and 0.60, respectively

  7. Home Performance with ENERGY STAR: Utility Bill Analysis on Homes Participating in Austin Energy's Program

    Energy Technology Data Exchange (ETDEWEB)

    Belzer, D.; Mosey, G.; Plympton, P.; Dagher, L.

    2007-07-01

    Home Performance with ENERGY STAR (HPwES) is a jointly managed program of the U.S. Department of Energy (DOE) and the U.S. Environmental Protection Agency (EPA). This program focuses on improving energy efficiency in existing homes via a whole-house approach to assessing and improving a home's energy performance, and helping to protect the environment. As one of HPwES's local sponsors, Austin Energy's HPwES program offers a complete home energy analysis and a list of recommendations for efficiency improvements, along with cost estimates. To determine the benefits of this program, the National Renewable Energy Laboratory (NREL) collaborated with the Pacific Northwest National Laboratory (PNNL) to conduct a statistical analysis using energy consumption data of HPwES homes provided by Austin Energy. This report provides preliminary estimates of average savings per home from the HPwES Loan Program for the period 1998 through 2006. The results from this preliminary analysis suggest that the HPwES program sponsored by Austin Energy had a very significant impact on reducing average cooling electricity for participating households. Overall, average savings were in the range of 25%-35%, and appear to be robust under various criteria for the number of households included in the analysis.

  8. A “Grammar” for assessing the performance of power-supply systems: Comparing nuclear energy to fossil energy

    International Nuclear Information System (INIS)

    Diaz-Maurin, François; Giampietro, Mario

    2013-01-01

    This article illustrates an innovative approach for the characterization and comparison of the performance of power-supply systems. The concept of ‘grammar’ forces to declare the pre-analytical decisions about: (i) semantic and formal categories used for the accounting – primary energy sources (PES), energy carriers (EC), and production factors; (ii) the set of functional and structural elements of the power-supply system included in the analysis. After having tamed the systemic ambiguity associated with energy accounting, it becomes possible to generate a double assessment referring to: (i) external constraints – the consumption of PES and the generation of waste and pollution; and (ii) internal constraints – the requirements of production factors such as human labor, power capacity, internal consumption of EC for making EC. The case study provided compares the production of EC (electricity) with “nuclear energy” and “fossil energy”. When considering internal constraints, nuclear energy requires about twice as much power capacity (5.9–9.5 kW/GWh vs. 2.6–2.9 kW/GWh) and 5–8 times more labor (570–640 h/GWh vs. 80–115 h/GWh). Things do not improve for nuclear energy when looking at external constraints – e.g. the relative scarcity of PES. This may explain the difficulties faced by nuclear energy to gain interest from investors. -- Highlights: ► A new approach to assess the performance of power-supply systems is provided. ► A biophysical analysis of the production process is based on the concept of grammar. ► A grammar is capable of handling the inherent ambiguity associated with energy. ► The performance of nuclear energy and fossil energy is compared using this grammar. ► Nuclear energy demonstrates a lower performance than fossil energy in making electricity.

  9. High Performance Healthcare Buildings: A Roadmap to Improved Energy Efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Singer, Brett C.; Tschudi, William F.

    2009-09-08

    This document presents a road map for improving the energy efficiency of hospitals and other healthcare facilities. The report compiles input from a broad array of experts in healthcare facility design and operations. The initial section lists challenges and barriers to efficiency improvements in healthcare. Opportunities are organized around the following ten themes: understanding and benchmarking energy use; best practices and training; codes and standards; improved utilization of existing HVAC designs and technology; innovation in HVAC design and technology; electrical system design; lighting; medical equipment and process loads; economic and organizational issues; and the design of next generation sustainable hospitals. Achieving energy efficiency will require a broad set of activities including research, development, deployment, demonstration, training, etc., organized around 48 specific objectives. Specific activities are prioritized in consideration of potential impact, likelihood of near- or mid-term feasibility and anticipated cost-effectiveness. This document is intended to be broad in consideration though not exhaustive. Opportunities and needs are identified and described with the goal of focusing efforts and resources.

  10. Attitude Towards Mandatory Pre-Marital HIV Testing Among ...

    African Journals Online (AJOL)

    Erah

    African Journal of Reproductive Health Mar 2010; 14(1): 83. ORIGINAL ... Males were about two times more likely to have positive attitude towards .... mental human rights of infected individuals. .... Senior Secondary School Education .... Mandatory premarital HIV test will prevent ..... the misconceptions that tend to promote.

  11. 5 CFR 9701.707 - Appeals of mandatory removal actions.

    Science.gov (United States)

    2010-01-01

    ... employee may appeal such actions to the Mandatory Removal Panel (MRP) established under § 9701.708. (b) Procedures. (1) The MRP will establish procedures for the fair, impartial, and expeditious assignment and... other matters as may be necessary to ensure the operation of the MRP. (2) The MRP will conduct a hearing...

  12. Mandatory rules and public policy in international contract law

    Czech Academy of Sciences Publication Activity Database

    Pauknerová, Monika

    -, č. 11 (2010), s. 29-43 ISSN 1612-3093 R&D Projects: GA ČR GA407/08/0188 Institutional research plan: CEZ:AV0Z70680506 Keywords : mandatory rules * public policy * Rome Convention Subject RIV: AG - Legal Sciences

  13. Breaching confidentiality: medical mandatory reporting laws in Iran.

    Science.gov (United States)

    Milanifar, Alireza; Larijani, Bagher; Paykarzadeh, Parvaneh; Ashtari, Golanna; Mehdi Akhondi, Mohammad

    2014-01-01

    Medical ethics is a realm where four important subjects of philosophy, medicine, theology and law are covered. Physicians and philosophers cooperation in this area will have great efficiency in the respective ethical rules formation. In addition to respect the autonomy of the patient, physician's obligation is to ensure that the medical intervention has benefit for the patient and the harm is minimal. There is an obvious conflict between duty of confidentiality and duty of mandatory reporting. Professional confidentiality is one of the basic components in building a constant physician-patient relationship which nowadays, beside the novelty, it is the subject of discussion. Legal obligation of confidentiality is not absolute. In physician-patient relationship, keeping patient's secrets and maintaining confidentiality is a legal and ethical duty, and disclosure of such secrets is mainly through specific statutes. Thus, there are a number of situations where breach of confidentiality is permitted in different legal systems. One of the situations where breaching confidentiality is permitted is the medical mandatory reporting to the relevant authority which is in accordance with many countries' legal systems. Some situations are considered in many countries legal systems' such as notification of births and deaths, infectious diseases, child abuse, sport and relevant events, medical errors, drug side effects and dangerous pregnancies. In this paper, we will examine and discuss medical mandatory reporting and its ethical and legal aspects in the judicial and legal system of Iran and few other countries. Finally we will suggest making Medical Mandatory Reporting Law in Iran.

  14. 15 CFR 2008.11 - Mandatory review for declassification.

    Science.gov (United States)

    2010-01-01

    ... 15 Commerce and Foreign Trade 3 2010-01-01 2010-01-01 false Mandatory review for declassification. 2008.11 Section 2008.11 Commerce and Foreign Trade Regulations Relating to Foreign Trade Agreements OFFICE OF THE UNITED STATES TRADE REPRESENTATIVE REGULATIONS TO IMPLEMENT E.O. 12065; OFFICE OF THE...

  15. Mandatory Identification Bar Checks: How Bouncers Are Doing Their Job

    Science.gov (United States)

    Monk-Turner, Elizabeth; Allen, John; Casten, John; Cowling, Catherine; Gray, Charles; Guhr, David; Hoofnagle, Kara; Huffman, Jessica; Mina, Moises; Moore, Brian

    2011-01-01

    The behavior of bouncers at on site establishments that served alcohol was observed. Our aim was to better understand how bouncers went about their job when the bar had a mandatory policy to check identification of all customers. Utilizing an ethnographic decision model, we found that bouncers were significantly more likely to card customers that…

  16. 31 CFR 50.4 - Mandatory participation in Program.

    Science.gov (United States)

    2010-07-01

    ... 31 Money and Finance: Treasury 1 2010-07-01 2010-07-01 false Mandatory participation in Program. 50.4 Section 50.4 Money and Finance: Treasury Office of the Secretary of the Treasury TERRORISM RISK... definition of an insurer under the Act is required to participate in the Program. ...

  17. 27 CFR 7.22 - Mandatory label information.

    Science.gov (United States)

    2010-04-01

    ... Beverages § 7.22 Mandatory label information. There shall be stated: (a) On the brand label: (1) Brand name... alcohol. (b) On the brand label or on a separate label (back or front): (1) In the case of imported malt... PHENYLALANINE.” (Paragraph (b)(6) approved by the Office of Management and Budget under Control No. 1512-0469...

  18. 27 CFR 4.32 - Mandatory label information.

    Science.gov (United States)

    2010-04-01

    ... Mandatory label information. (a) There shall be stated on the brand label: (1) Brand name, in accordance... the bottle. (c) There shall be stated on the brand label or on a back label a statement that the... the Office of Management and Budget under Control Number 1512-0469) [T.D. 6521, 25 FR 13835, Dec. 29...

  19. Mandatory Parent Education Programs Can Create Positive Youth Sport Experiences

    Science.gov (United States)

    Christofferson, Jennifer; Strand, Bradford

    2016-01-01

    Youth sport leaders must not ignore the influence parents have on creating a positive developmental experience for young athletes. Therefore, expectations involving parental involvement and conduct must be addressed prior to athletes' participation. This article aims to examine the importance of creating mandatory parental training programs for…

  20. 12 CFR 403.7 - Mandatory review for declassification.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Mandatory review for declassification. 403.7 Section 403.7 Banks and Banking EXPORT-IMPORT BANK OF THE UNITED STATES CLASSIFICATION, DECLASSIFICATION... effort. Requests may be addressed to the: General Counsel, Export-Import Bank of the U.S., 811 Vermont...

  1. Mandatory Use of Electronic Health Records: Overcoming Physician Resistance

    Science.gov (United States)

    Brown, Viseeta K.

    2012-01-01

    Literature supports the idea that electronic health records hold tremendous value for the healthcare system in that it increases patient safety, improves the quality of care and provides greater efficiency. The move toward mandatory implementation of electronic health records is a growing concern in the United States health care industry. The…

  2. 15 CFR 4a.7 - Mandatory review for declassification.

    Science.gov (United States)

    2010-01-01

    ... Deputy Assistant Secretary for Security, U.S. Department of Commerce, Room 1069, 14th and Constitution... under the provisions of the Department of Commerce National Security Manual, the DAS shall notify the... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false Mandatory review for declassification...

  3. Competition with mandatory labeling of genetically modified products

    NARCIS (Netherlands)

    Toolsema-Veldman, Linda

    2005-01-01

    In April 2004, the European Union adopted a new legislative framework for genetically modified (GM) organisms. This framework regulates the placing on the market of GM products, and demands these products to be labeled as such. We present a duopoly model with vertical differentiation and mandatory

  4. Mandatory Driver Training and Road Safety: The Quebec Experience.

    Science.gov (United States)

    Potvin, Louise; And Others

    1988-01-01

    1983 legislation making driver training courses mandatory for any person in Quebec seeking a first driver's license had no effect on the risk of accident or the mortality/morbidity rate for newly licensed drivers over 18. However, since 1983 more women under 18 are becoming licensed, and their risks may be increased. (Author/BJV)

  5. Which analysts benefited most from mandatory IFRS adoption in Europe?

    NARCIS (Netherlands)

    Beuselinck, Christof; Joos, Philip; Khurana, I.K.; van der Meulen, Sofie

    2017-01-01

    This study examines whether financial analysts' research structure and portfolio selection choices helped in improving relative earnings forecast accuracy around mandatory IFRS adoption in Europe. Using a sample of 68,665 one-year ahead forecasts for 1,980 publicly listed firms, we find that

  6. Mandatory or Flexible: Whither Retirement Age Policy? | Ibiwoye ...

    African Journals Online (AJOL)

    ... to flexible retirement. It also found that flexible policy will have a positive welfare effect as many employees can then take care of their extended span of dependants for a longer period and employee productivity will also be improved. Key words: Retirement, Mandatory, Flexible, Pension Plan, Extended Family System.

  7. 41 CFR 51-5.2 - Mandatory source requirement.

    Science.gov (United States)

    2010-07-01

    ... 41 Public Contracts and Property Management 1 2010-07-01 2010-07-01 true Mandatory source requirement. 51-5.2 Section 51-5.2 Public Contracts and Property Management Other Provisions Relating to... such as the Defense Logistics Agency and the General Services Administration, and certain commercial...

  8. 27 CFR 5.32 - Mandatory label information.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Mandatory label information. 5.32 Section 5.32 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF THE TREASURY LIQUORS LABELING AND ADVERTISING OF DISTILLED SPIRITS Labeling Requirements for...

  9. 78 FR 34565 - Modification of Mandatory Label Information for Wine

    Science.gov (United States)

    2013-06-10

    ... for Wine AGENCY: Alcohol and Tobacco Tax and Trade Bureau, Treasury. ACTION: Final rule; Treasury... the mandatory labeling requirements for wine. The regulatory change permits alcohol content to appear... regulatory change provides greater flexibility in wine labeling, and will conform the TTB wine labeling...

  10. 76 FR 74050 - Measured Building Energy Performance Data Taxonomy

    Science.gov (United States)

    2011-11-30

    ... developed using a ``top-down'' approach, based on a logical understanding of building performance... were developed using a ``bottom-up'' approach, by compiling and editing lists of fields from existing...

  11. Do the Czech Production Plants Measure the Performance of Energy Processes?

    Directory of Open Access Journals (Sweden)

    Zuzana Tučková

    2016-04-01

    Full Text Available The research was focused to the actual situation in Performance Measurement of the energy processes in Czech production plants. The results are back – upped by the previous researches which were aimed to performance measurement methods usage in the whole organizational structure of the plants. Although the most of big industrial companies declared using of modern Performance Measurements methods, the previous researches shown that it is not purely true. The bigger differences were found in the energy area – energy processes. The authors compared the Energy concepts of European Union (EU and Czech Republic (CZ which are very different and do not create any possibilities for manager’s clear decision in the process management strategy of energy processes in their companies. Next step included the Energy department’s analysis. The significant part of energy processes in the production plants is still not mapped, described and summarized to one methodical manual for managing and performance measurement.

  12. Modeling the Energy Performance of LoRaWAN

    OpenAIRE

    Casals, Lluís; Mir, Bernat; Vidal, Rafael; Gomez, Carles

    2017-01-01

    LoRaWAN is a flagship Low-Power Wide Area Network (LPWAN) technology that has highly attracted much attention from the community in recent years. Many LoRaWAN end-devices, such as sensors or actuators, are expected not to be powered by the electricity grid; therefore, it is crucial to investigate the energy consumption of LoRaWAN. However, published works have only focused on this topic to a limited extent. In this paper, we present analytical models that allow the characterization of LoRaWAN...

  13. Environmental Performance Report 2014. NREL (National Renewable Energy Laboratory)

    Energy Technology Data Exchange (ETDEWEB)

    Rukavina, Frank [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Myers, Lissa [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Elmore, Adrienne [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Ruckman, Kathryn [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Gray, Lori [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Margason, Laura [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Jorgensen, Lisa [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Smith, Robert [National Renewable Energy Laboratory (NREL), Golden, CO (United States); Sweeney, Robin [National Renewable Energy Laboratory (NREL), Golden, CO (United States)

    2015-08-01

    The purpose of this report is to ensure that the U.S. Department of Energy (DOE) and the public receive timely, accurate information about events that have affected or could adversely affect the health, safety, and security of the public or workers, the environment, or the operations of DOE facilities. This report meets the DOE requirements of the Annual Site Environmental Report and has been prepared in accordance with the DOE Order 231.1B Chg 1, Environment, Safety and Health Reporting.

  14. The Influence of Early Protein Energy Malnutrition on Subsequent Behavior and Intellectual Performance.

    Science.gov (United States)

    Gupta, Sarita

    1990-01-01

    Protein-energy malnutrition in early childhood, as seen in many developing countries, influences subsequent behavior and intellectual performance. These impairments are associated with further reduction in fine motor skills and academic performance. (Author)

  15. Real estate market and building energy performance: Data for a mass appraisal approach

    Directory of Open Access Journals (Sweden)

    Pietro Bonifaci

    2015-12-01

    Data are related to the analysis performed in Bonifaci and Copiello [1], about the relationship between house prices and building energy performance, that is to say, the willingness to pay in order to benefit from more efficient dwellings.

  16. Multi-site musculoskeletal pain in Swedish police: associations with discomfort from wearing mandatory equipment and prolonged sitting.

    Science.gov (United States)

    Larsen, Louise Bæk; Andersson, Elisabeth Elgmark; Tranberg, Roy; Ramstrand, Nerrolyn

    2018-05-01

    Musculoskeletal disorders are considered as a major issue affecting the health and well-being of active duty police. Discomfort from wearing mandatory equipment and sitting for long periods of time in fleet vehicles are workload factors linked to musculoskeletal disorders in police. This study aims to determine the prevalence of multi-site musculoskeletal pain among Swedish police and to explore the possible association to discomfort experience when wearing mandatory equipment and sitting for long periods in fleet vehicles. In this cross-sectional study responses from 4185 police were collected through a self-administered online survey including questions about physical work environment, mandatory equipment and musculoskeletal pain. Multi-site pain was determined through summing pain sites from four body regions. Binomial logistic regression was performed to explore the association between multi-site musculoskeletal pain: (1) discomfort from wearing mandatory equipment and (2) sitting for long periods in fleet vehicles. The prevalence of multi-site musculoskeletal pain at least 1 day per week within the previous 3 months was 41.3%. A statistically significant association between discomfort from wearing mandatory equipment and multi-site musculoskeletal pain was found; duty belt [OR 5.42 (95% CI 4.56-6.43)] as well as body armour [OR 2.69 (95% CI 2.11-3.42)]. Sitting for long periods in fleet vehicles was not significantly associated to multi-site musculoskeletal pain. Multi-site musculoskeletal pain is a considerable problem among Swedish police and modifying mandatory equipment to decrease discomfort is suggested as a potential means of decreasing the musculoskeletal pain experienced by many police officers.

  17. Energy harvesting influences electrochemical performance of microbial fuel cells

    Science.gov (United States)

    Lobo, Fernanda Leite; Wang, Xin; Ren, Zhiyong Jason

    2017-07-01

    Microbial fuel cells (MFCs) can be effective power sources for remote sensing, wastewater treatment and environmental remediation, but their performance needs significant improvement. This study systematically analyzes how active harvesting using electrical circuits increased MFC system outputs as compared to passive resistors not only in the traditional maximal power point (MPP) but also in other desired operating points such as the maximum current point (MCP) and the maximum voltage point (MVP). Results show that active harvesting in MPP increased power output by 81-375% and active harvesting in MCP increased Coulombic efficiency by 207-805% compared with resisters operated at the same points. The cyclic voltammograms revealed redox potential shifts and supported the performance data. The findings demonstrate that active harvesting is a very effective approach to improve MFC performance across different operating points.

  18. Energy-Performance-Based Design-Build Process: Strategies for Procuring High-Performance Buildings on Typical Construction Budgets: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Scheib, J.; Pless, S.; Torcellini, P.

    2014-08-01

    NREL experienced a significant increase in employees and facilities on our 327-acre main campus in Golden, Colorado over the past five years. To support this growth, researchers developed and demonstrated a new building acquisition method that successfully integrates energy efficiency requirements into the design-build requests for proposals and contracts. We piloted this energy performance based design-build process with our first new construction project in 2008. We have since replicated and evolved the process for large office buildings, a smart grid research laboratory, a supercomputer, a parking structure, and a cafeteria. Each project incorporated aggressive efficiency strategies using contractual energy use requirements in the design-build contracts, all on typical construction budgets. We have found that when energy efficiency is a core project requirement as defined at the beginning of a project, innovative design-build teams can integrate the most cost effective and high performance efficiency strategies on typical construction budgets. When the design-build contract includes measurable energy requirements and is set up to incentivize design-build teams to focus on achieving high performance in actual operations, owners can now expect their facilities to perform. As NREL completed the new construction in 2013, we have documented our best practices in training materials and a how-to guide so that other owners and owner's representatives can replicate our successes and learn from our experiences in attaining market viable, world-class energy performance in the built environment.

  19. Energy performance and energy saving of life-support systems in ...

    African Journals Online (AJOL)

    The contemporary automation systems of buildings ensure the most efficient control automation for heating, ventilation, lighting, hot water supply systems. This leads to significant increase of operation efficiency and reduction of energy costs. The integrated energy saving processes and functions are optimized depending ...

  20. Performance indices and evaluation of algorithms in building energy efficient design optimization

    International Nuclear Information System (INIS)

    Si, Binghui; Tian, Zhichao; Jin, Xing; Zhou, Xin; Tang, Peng; Shi, Xing

    2016-01-01

    Building energy efficient design optimization is an emerging technique that is increasingly being used to design buildings with better overall performance and a particular emphasis on energy efficiency. To achieve building energy efficient design optimization, algorithms are vital to generate new designs and thus drive the design optimization process. Therefore, the performance of algorithms is crucial to achieving effective energy efficient design techniques. This study evaluates algorithms used for building energy efficient design optimization. A set of performance indices, namely, stability, robustness, validity, speed, coverage, and locality, is proposed to evaluate the overall performance of algorithms. A benchmark building and a design optimization problem are also developed. Hooke–Jeeves algorithm, Multi-Objective Genetic Algorithm II, and Multi-Objective Particle Swarm Optimization algorithm are evaluated by using the proposed performance indices and benchmark design problem. Results indicate that no algorithm performs best in all six areas. Therefore, when facing an energy efficient design problem, the algorithm must be carefully selected based on the nature of the problem and the performance indices that matter the most. - Highlights: • Six indices of algorithm performance in building energy optimization are developed. • For each index, its concept is defined and the calculation formulas are proposed. • A benchmark building and benchmark energy efficient design problem are proposed. • The performance of three selected algorithms are evaluated.

  1. Corrosion performance of iron aluminides in fossil energy environments

    Energy Technology Data Exchange (ETDEWEB)

    Natesan, K. [Argonne National Lab., IL (United States). Energy Technology Div.

    1997-12-01

    Corrosion of metallic structural materials in complex gas environments of coal gasification and combustion is a potential problem. The corrosion process is dictated by concentrations of two key constituents: sulfur as H{sub 2}S or SO{sub 2} and chlorine as HCl. This paper presents a comprehensive review of the current status of the corrosion performance of alumina scales that are thermally grown on Fe-base alloys, including iron aluminides, in multicomponent gas environments of typical coal-conversion systems. Mechanisms of scale development/breakdown, performance envelopes for long-term usage of these materials, approaches to modifying the surfaces of engineering alloys by cladding or coating them with intermetallics, and in-service experience with these materials are emphasized. The results are compared with the performance of chromia-forming alloys in similar environments. The paper also discusses the available information on corrosion performance of alloys whose surfaces were enriched with Al by the electrospark deposition process or by weld overlay techniques.

  2. (JASR) Vol. 11, No. 1, 2011 PERFORMANCE AND ENERGY ...

    African Journals Online (AJOL)

    Dr Ezeachi

    Department of Animal Science, University of Benin, Benin City, Nigeria ... weights of the birds with millet offal performing better than maize offal (p<0.05). .... To acclimatize the birds to the cages and feed, a 3-day adaptation period was allowed.

  3. Building Performance Simulation for Sustainable Energy Use in Buildings

    NARCIS (Netherlands)

    Hensen, J.L.M.

    2010-01-01

    This paper aims to provide a general view of the background and current state of building performance simulation, which has the potential to deliver, directly or indirectly, substantial benefits to building stakeholders and to the environment. However the building simulation community faces many

  4. A methodology for energy performance classification of residential building stock of Hamirpur

    Directory of Open Access Journals (Sweden)

    Aniket Sharma

    2017-12-01

    Full Text Available In India, there are various codes, standards, guidelines and rating systems launched to make energy intensive and large sized buildings energy efficient whereas independent residential buildings are not covered even though they exist most in numbers of total housing stock. This paper presents a case study methodology for energy performance assessment of existing residential stock of Hamirpur that can be used to develop suitable energy efficiency regulations. The paper discusses the trend of residential development in Hamirpur followed by classification based on usage, condition, predominant material use, ownership size and number of rooms, source of lighting, assets available, number of storey and plot sizes using primary and secondary data. It results in identification of predominant materials used and other characteristics in each of urban and rural area. Further cradle to site embodied energy index of various dominant building materials and their market available alternative materials is calculated from secondary literature and by calculating transportation energy. One representative existing building is selected in each of urban and rural area and their energy performance is evaluated for material embodied energy and operational energy using simulation. Further alternatives are developed based on other dominant materials in each area and evaluated for change in embodied and operational energy. This paper identifies the energy performance of representative houses for both areas and in no way advocates the preference of one type over another. The paper demonstrates a methodology by which energy performance assessment of houses shall be done and also highlights further research.

  5. U.S. Department of Energy FY 1994 and 1995 annual performance report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    This is the Department of Energy`s first Annual Performance Report. The topics of the report include a new era for the US DOE, sustainable energy, science and technology, national security--reducing the global nuclear danger, environmental quality, economic productivity through a competitive economy and the critical success factors--assessing the way the US DOE does business.

  6. The expected performance of local energy visions in Europe : A governance perspective

    NARCIS (Netherlands)

    Van Bueren, E.M.; Dignum, M.; Steenhuisen, B.M.

    2015-01-01

    This paper offers insights into the expected performance of Sustainable Energy Action Plans (SEAPs) as a policy instrument, a local energy vision initiated by the EU and used by municipalities across Europe. How are SEAPs aiming to contribute to the process of local energy transition and how can

  7. Impact of Air Tightness on the Evaluation of Building Energy Performance in Lithuania

    Directory of Open Access Journals (Sweden)

    Jolanta Šadauskienė

    2014-08-01

    Full Text Available In order to fulfil the European Energy Performance of Buildings Directive (EPBD requirements for the reduction of energy consumption, European national requirements have been created for building envelope thermal properties and calculation methodology to determine if building energy efficiency is created. This is however not true in all methodologies. The necessity of building air tightness appears only for new A class buildings, and there are no requirements for air tightness for other building classes. Therefore, the aim of this work is to improve the methodology for the calculation of energy efficiency of buildings, while taking into account the air tightness of the buildings. In order to achieve this aim, the sum energy consumption of investigated buildings was calculated, energy efficiency classes were determined, air tightness of the buildings was measured, and reasons for insufficient air tightness were analyzed. Investigation results show that the average value of air tightness of A energy efficiency class buildings is 0.6 h−1. The results of other investigated buildings, corresponding to B and C energy efficiency classes, show insufficient air tightness (the average n50 value is 6 h−1; herewith, energy consumption for heating is higher than calculated, according to the energy efficiency methodology. This paper provides an energy performance evaluation scheme, under which performed evaluation of energy performance of buildings ensures high quality construction work, building durability, and the reliability of heat-loss calculations.

  8. Performance of Generating Plant: Managing the Changes. Part 3: Renewable energy plant: reports on wind, photovoltaics and biomas energies

    Energy Technology Data Exchange (ETDEWEB)

    Manoha, Bruno; Cohen, Martin [Electricite de France (France)

    2008-05-15

    The WEC Committee on the Performance of Generating Plant (PGP) has been collecting and analysing power plant performance statistics worldwide for more than 30 years and has produced regular reports, which include examples of advanced techniques and methods for improving power plant performance through benchmarking. A series of reports from the various working groups was issued in 2008. This reference presents the results of Working Group 3 (WG3). WG3 will promote the introduction of performance indicators for renewable energy generating plant (wind, geothermal, solar and biomass) developed by the Committee. It will also assess selected transitional technology issues and environmental factors related to non-conventional technologies. The WG3 report includes sections on Wind Energy Today, Photovoltaics Energy Today, Biomass Electricity Today and appendices.

  9. Potential for the Use of Energy Savings Performance Contracts to Reduce Energy Consumption and Provide Energy and Cost Savings in Non-Building Applications

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Charles; Green, Andrew S.; Dahle, Douglas; Barnett, John; Butler, Pat; Kerner, David

    2013-08-01

    The findings of this study indicate that potential exists in non-building applications to save energy and costs. This potential could save billions of federal dollars, reduce reliance on fossil fuels, increase energy independence and security, and reduce greenhouse gas emissions. The Federal Government has nearly twenty years of experience with achieving similar energy cost reductions, and letting the energy costs savings pay for themselves, by applying energy savings performance contracts (ESPC) inits buildings. Currently, the application of ESPCs is limited by statute to federal buildings. This study indicates that ESPCs can be a compatible and effective contracting tool for achieving savings in non-building applications.

  10. Energy Performance Improvement in the Arab Beets Arena, Company Construction Materials Cienfuegos

    International Nuclear Information System (INIS)

    Bericiarto Pérez, Frank Abel; Castro Perdomo, Nelson; López Bastida, Eduardo J.; Fuentes Díaz, Damarys

    2017-01-01

    Energy consumption over the years through the use of fossil fuels has led to the exhaustion of them, which is why large industries see energy management as an alternative to reduce their energy consumption. At present one of the most important tasks within organizations is energy efficiency due to the price of hydrocarbons, the pollution generated by them, and the need to reduce costs. The present research aims to apply the stages of energy planning in correspondence with the NC-ISO 50001: 2011 in the Construction Materials Companies, Cienfuegos. The work addresses the issues related to the Quality Management System, the Energy Management System and with it the Production Planning and Energy Planning. It performs the energy characterization of the organization and exposes the stages for energy planning. Energy planning is carried out for the UEB Áridos Arena Arimao, sand deposit E l Canal . (author)

  11. The importance of surface finish to energy performance

    Directory of Open Access Journals (Sweden)

    Smith Geoff B.

    2017-01-01

    Full Text Available Power generation in solar energy systems, thermal control in buildings and mitigation of the Urban Heat Island problem, are all sensitive to directional response to incoming radiation. The radiation absorption and emission profile also plays a crucial role in each system's response and depends strongly on surface finish. This important sensitivity needs wider recognition in materials data sheets, system modeling, plus in materials and environmental engineering. The impact of surface roughness on thermal response of natural and man-made external environments is examined. Important examples will be given of the role of surface finish within each class. Total emittance links to the way surface finish influences directional emittance E(θ. Smooth surface thermal emittance on PV module covers, many solar absorbers, some roof paints, polished concrete, and glass windows can be up to 15% different from insulator results based on fully diffuse models of the same material. Widespread evidence indicates smooth metals and low-E solar absorber surfaces cool faster, and smooth insulators slower than previously thought. Matt paint is cooler than low sheen paint under the same solar heating impacts and normal concrete cooler than polished. Emittance for water is the prime environmental example of oblique impacts as it reflects strongly at oblique incidence, which leads to a significant drop in E(θ. Ripples or waves however raise water's average emittance. A surprise in this work was the high sensitivity of total E and its angular components to roughness in the depth range of 0.1–0.8 μm, which are well under ambient thermal IR wavelengths of 3–30 μm but common in metal finishing. Parallel energy flows such as evaporation and convective cooling vary if emittance varies. Thermal image analysis can provide insights into angular radiative effects.

  12. Optimizing Performance of a Thermal Energy Storage System

    Science.gov (United States)

    Subirats Soler, Monica

    In this thesis, the problem of electricity demand shifting for the cooling needs of a large institution using a thermal energy storage (TES) tank is considered. The system is formed by electric chillers, cooling towers and a TES tank that can store energy for the cooling demand of most days, but not for the hottest ones. The goal is to supply all the cooling needed while minimizing the cost. This is done by shifting the cooling demand to night and early morning hours, when electricity is cheaper and due to lower temperatures, the chillers work more efficiently. This is all done with the help of the TES tank, that acts as a buffer storing chilled water. After a series of assumptions and simplifications, the cost function becomes convex and thus a minimum solution exists. However, from previous work only the chillers were considered, omitting the negative effect that other components of the system, such as cooling towers, had on the overall cost of operation. Using data from the operation of the power plant under real conditions, a method to model the whole system is presented in this thesis. In addition, the algorithm relied on the knowledge of an accurate prediction of the cooling demand, which obviously is not known in advance. A method to predict it starting from a forecasting of the temperature is presented. Finally, the algorithm can be easily modified to allow the imposition constraints that limit the maximum power use of chillers, during specific periods, in response to the overall needs of the micro-grid.

  13. The SSG Wave Energy Converter: Performance, Status and Recent Developments

    DEFF Research Database (Denmark)

    Vicinanza, Diego; Margheritini, Lucia; Kofoed, Jens Peter

    2012-01-01

    through turbines for electricity production. The system utilizes a wide spectrum of different wave conditions by means of multiple reservoirs, located at different levels above the still water level. Thereby, it obtains a high overall efficiency and it can be suitable for shoreline and breakwater...... applications, presenting particular advantages such as: sharing structure costs, availability of grid connection and infrastructures, recirculation of water inside the harbor, as the outlet of the turbines is on the rear part of the system. Recently, plans for the SSG pilot installation were in progress...... on wave loadings and on hydraulic performances (overtopping and reflection) in order to optimize the structure design. This paper addresses the influence of various parameters (geometry, wave characteristics) on overtopping, reflection and wave loading and it draws conclusions on performances...

  14. Energy efficiency and performance indicators of European electricity market

    Directory of Open Access Journals (Sweden)

    Constantin DUGULEANĂ

    2015-06-01

    Full Text Available The electric power system plays a vital role in the development of every country, ensuring the “fuel” which feeds its economic motor. The efficient functioning of this motor is essential for economy. The efficiency and the performances of electric power systems are reflected on the living level of population, through the money spent and the satisfaction level of their needs. The continuity of power distribution process, the good communication between the suppliers and consumers, the promptitude of interventions, the environment protection - all these are aspects characterizing the performance level of power distribution systems. The paper analyzes the evolution of quality indicators of power distribution systems both for countries’ level and for population on European market of electricity.

  15. Occupant performance and building energy consumption with different philosophies of determining acceptable thermal conditions

    DEFF Research Database (Denmark)

    Toftum, Jørn; Andersen, Rune Vinther; Jensen, Kasper Lynge

    2009-01-01

    Based on building energy and indoor environment simulations, this study uses a recently developed method relying on Bayesian Network theory to estimate and compare the consequences for occupant performance and energy consumption of applying temperature criteria set according to the adaptive model...... configurations, especially in the tropical climate, the estimated performance differed only modestly between configurations. However, energy consumption was always lower in buildings without mechanical cooling, particularly so in the tropical climate. The findings indicate that determining acceptable indoor...... thermal environments with the adaptive comfort model may result in significant energy savings and at the same time will not have large consequences for the mental performance of occupants....

  16. Development of an Online Toolkit for Measuring Commercial Building Energy Efficiency Performance -- Scoping Study

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Na

    2013-03-13

    This study analyzes the market needs for building performance evaluation tools. It identifies the existing gaps and provides a roadmap for the U.S. Department of Energy (DOE) to develop a toolkit with which to optimize energy performance of a commercial building over its life cycle.

  17. Expanding Energy Performance Contracting in china: policy solutions and market mechanisms

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Bo [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Price, Lynn [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Liu, Xu [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Meng, Lu [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Shi, Wenjing [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Evans, Meredydd [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Roshchanka, Volha [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Yu, Sha [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-07-19

    Energy performance contracting is an important market mechanism that uses energy savings to pay over time for the upfront costs of energy efficiency retrofits in buildings, industries, and other types of facilities. Through energy performance contracts (EPCs), Energy Service Companies (ESCOs) play an important role in implementing energy efficiency retrofits. Both China and the United States have large markets for EPCs and significant opportunities for growth. The Chinese government has made great efforts in promoting the country’s ESCO business and expanding its EPC markets. This paper makes a series of recommendations for China to adopt more ambitious policy measures to encourage deep energy savings projects via EPCs. These recommendations are built on initial insights from a white paper developed by researchers at the Pacific Northwest National Laboratory and the Lawrence Berkeley National Laboratory with the assistance from the ESCO Committee of China’s Energy Conservation Association (EMCA). Key recommendations are listed below.

  18. Commissioning of building HVAC systems for improvement of energy performance; Commissioning of building HVAC systems for improvement of energy performance. Teilnahme IEA-ECBCS Annex 40 (Betreiberkompetenz)

    Energy Technology Data Exchange (ETDEWEB)

    Chuard, J.-M.

    2005-06-15

    This paper takes a look at the tasks performed in Task 40 of the 'Energy Conservation in Buildings and Community Systems ECBCS' programme of the International Energy Agency IEA that is taking a look at the commissioning of building HVAC systems with the aim of improving the energy performance of such systems. Emphasis is put on the Swiss contribution to the task. This well-illustrated paper presents information on the structure of the task, time-lines and a diagram for its implementation structures. Also, the countries participating in Task 40 and their representatives are listed, and various work already published by the annex is noted. The paper places a focus on operator competence and lists points to be taken into account when carrying out work on optimising energy consumption. The various processes involved are noted and discussed. Management guidelines are presented and economical and market aspects are discussed. Finally, projects that will continue the work are noted.

  19. Commissioning of building HVAC systems for improvement of energy performance; Commissioning of building HVAC systems for improvement of energy performance. Teilnahme IEA-ECBCS Annex 40 (Betreiberkompetenz)

    Energy Technology Data Exchange (ETDEWEB)

    Chuard, J -M

    2005-06-15

    This paper takes a look at the tasks performed in Task 40 of the 'Energy Conservation in Buildings and Community Systems ECBCS' programme of the International Energy Agency IEA that is taking a look at the commissioning of building HVAC systems with the aim of improving the energy performance of such systems. Emphasis is put on the Swiss contribution to the task. This well-illustrated paper presents information on the structure of the task, time-lines and a diagram for its implementation structures. Also, the countries participating in Task 40 and their representatives are listed, and various work already published by the annex is noted. The paper places a focus on operator competence and lists points to be taken into account when carrying out work on optimising energy consumption. The various processes involved are noted and discussed. Management guidelines are presented and economical and market aspects are discussed. Finally, projects that will continue the work are noted.

  20. Solar energy system performance evaluation. Seasonal report for Wormser, Columbia, South Carolina

    Science.gov (United States)

    1980-01-01

    The Wormser Solar Energy System's operational performance from April 1979 through March 1980 was evaluated. The space heating subsystem met 42 percent of the measured space heating load and the hot water subsystem met 23 percent of the measured hot water demand. Net electrical energy savings were 4.36 million Btu's or 1277 kwh. Fossil energy savings will increase considerably if the uncontrolled solar energy input to the building is considered.

  1. A Correlated Model for Evaluating Performance and Energy of Cloud System Given System Reliability

    Directory of Open Access Journals (Sweden)

    Hongli Zhang

    2015-01-01

    Full Text Available The serious issue of energy consumption for high performance computing systems has attracted much attention. Performance and energy-saving have become important measures of a computing system. In the cloud computing environment, the systems usually allocate various resources (such as CPU, Memory, Storage, etc. on multiple virtual machines (VMs for executing tasks. Therefore, the problem of resource allocation for running VMs should have significant influence on both system performance and energy consumption. For different processor utilizations assigned to the VM, there exists the tradeoff between energy consumption and task completion time when a given task is executed by the VMs. Moreover, the hardware failure, software failure and restoration characteristics also have obvious influences on overall performance and energy. In this paper, a correlated model is built to analyze both performance and energy in the VM execution environment given the reliability restriction, and an optimization model is presented to derive the most effective solution of processor utilization for the VM. Then, the tradeoff between energy-saving and task completion time is studied and balanced when the VMs execute given tasks. Numerical examples are illustrated to build the performance-energy correlated model and evaluate the expected values of task completion time and consumed energy.

  2. Astrometric Calibration and Performance of the Dark Energy Camera

    Energy Technology Data Exchange (ETDEWEB)

    Bernstein, G. M.; Armstrong, R.; Plazas, A. A.; Walker, A. R.; Abbott, T. M. C.; Allam, S.; Bechtol, K.; Benoit-Lévy, A.; Brooks, D.; Burke, D. L.; Rosell, A. Carnero; Kind, M. Carrasco; Carretero, J.; Cunha, C. E.; Costa, L. N. da; DePoy, D. L.; Desai, S.; Diehl, H. T.; Eifler, T. F.; Fernandez, E.; Fosalba, P.; Frieman, J.; García-Bellido, J.; Gerdes, D. W.; Gruen, D.; Gruendl, R. A.; Gschwend, J.; Gutierrez, G.; Honscheid, K.; James, D. J.; Kent, S.; Krause, E.; Kuehn, K.; Kuropatkin, N.; Li, T. S.; Maia, M. A. G.; March, M.; Marshall, J. L.; Menanteau, F.; Miquel, R.; Ogando, R. L. C.; Reil, K.; Roodman, A.; Rykoff, E. S.; Sanchez, E.; Scarpine, V.; Schindler, R.; Schubnell, M.; Sevilla-Noarbe, I.; Smith, M.; Smith, R. C.; Soares-Santos, M.; Sobreira, F.; Suchyta, E.; Swanson, M. E. C.; Tarle, G.

    2017-05-30

    We characterize the variation in photometric response of the Dark Energy Camera (DECam) across its 520~Mpix science array during 4 years of operation. These variations are measured using high signal-to-noise aperture photometry of $>10^7$ stellar images in thousands of exposures of a few selected fields, with the telescope dithered to move the sources around the array. A calibration procedure based on these results brings the RMS variation in aperture magnitudes of bright stars on cloudless nights down to 2--3 mmag, with <1 mmag of correlated photometric errors for stars separated by $\\ge20$". On cloudless nights, any departures of the exposure zeropoints from a secant airmass law exceeding >1 mmag are plausibly attributable to spatial/temporal variations in aperture corrections. These variations can be inferred and corrected by measuring the fraction of stellar light in an annulus between 6" and 8" diameter. Key elements of this calibration include: correction of amplifier nonlinearities; distinguishing pixel-area variations and stray light from quantum-efficiency variations in the flat fields; field-dependent color corrections; and the use of an aperture-correction proxy. The DECam response pattern across the 2-degree field drifts over months by up to $\\pm7$ mmag, in a nearly-wavelength-independent low-order pattern. We find no fundamental barriers to pushing global photometric calibrations toward mmag accuracy.

  3. Energy Performance of Water-based and Air-based Cooling Systems in Plus-energy Housing

    DEFF Research Database (Denmark)

    Andersen, Mads E.; Schøtt, Jacob; Kazanci, Ongun Berk

    2016-01-01

    -space, and air-to-water heat pump vs. ground heat exchanger as cooling source) on the system energy performance were investigated while achieving the same thermal indoor conditions. The results show that the water-based floor cooling system performed better than the air-based cooling system in terms of energy...... energy use reductions. The coupling of radiant floor with the ground enables to obtain “free” cooling, although the brine pump power should be kept to a minimum to fully take advantage of this solution. By implementing a ground heat exchanger instead of the heat pump and use the crawl-space air as intake...... air an improvement of 37% was achieved. The cooling demand should be minimized in the design phase as a priority and then the resulting cooling load should be addressed with the most energy efficient cooling strategy. The floor cooling coupled with a ground heat exchanger was shown to be an effective...

  4. Performance assessment of a novel hybrid district energy system

    International Nuclear Information System (INIS)

    Coskun, C.; Oktay, Z.; Dincer, I.

    2012-01-01

    In this paper, a new hybrid system for improving the efficiency of geothermal district heating systems (GDHSs) is proposed. This hybrid system consists of biogas based electricity production and a water-to-water geothermal heat pump unit (GHPU), which uses the waste heat for both heating and domestic hot water purposes. Electricity generated by the biogas plant (BP) is utilized to drive the GDHS's pumps, BP systems and the heat pump units. Both the biogas reactor heating unit and the heat pump unit utilize the waste heat from the GDHS and use the system as a heat source. The feasibility of utilizing a hybrid system in order to increase the overall system (GDHS + BP + GHPU) efficiency is then investigated for possible efficiency improvements. The Edremit GDHS in Turkey, which is selected for investigation in this case study, reinjects 16.8 MW of thermal power into the river at a low temperature; namely at 40 °C. Such a temperature is ideal for mesophilic bacterial growth in the digestion process during biogas production. 1.45 MW of biogas based electricity production potential is obtainable from the waste heat output of the Edremit GDHS. The average overall system efficiencies through the utilization of this kind of hybridized system approach are increased by 7.5% energetically and 13% for exergetically. - Highlights: ► A new hybrid system is proposed for improving the efficiency of geothermal district heating systems (GDHSs). ► The average overall system efficiencies are increased by 7.5% for energy and 13% for exergy, respectively. ► Various energetic and exergetic parameters are studied.

  5. Energy Efficiency and Performance Limiting Effects in Thermo-Osmotic Energy Conversion from Low-Grade Heat.

    Science.gov (United States)

    Straub, Anthony P; Elimelech, Menachem

    2017-11-07

    Low-grade heat energy from sources below 100 °C is available in massive quantities around the world, but cannot be converted to electricity effectively using existing technologies due to variability in the heat output and the small temperature difference between the source and environment. The recently developed thermo-osmotic energy conversion (TOEC) process has the potential to harvest energy from low-grade heat sources by using a temperature difference to create a pressurized liquid flux across a membrane, which can be converted to mechanical work via a turbine. In this study, we perform the first analysis of energy efficiency and the expected performance of the TOEC technology, focusing on systems utilizing hydrophobic porous vapor-gap membranes and water as a working fluid. We begin by developing a framework to analyze realistic mass and heat transport in the process, probing the impact of various membrane parameters and system operating conditions. Our analysis reveals that an optimized system can achieve heat-to-electricity energy conversion efficiencies up to 4.1% (34% of the Carnot efficiency) with hot and cold working temperatures of 60 and 20 °C, respectively, and an operating pressure of 5 MPa (50 bar). Lower energy efficiencies, however, will occur in systems operating with high power densities (>5 W/m 2 ) and with finite-sized heat exchangers. We identify that the most important membrane properties for achieving high performance are an asymmetric pore structure, high pressure resistance, a high porosity, and a thickness of 30 to 100 μm. We also quantify the benefits in performance from utilizing deaerated water streams, strong hydrodynamic mixing in the membrane module, and high heat exchanger efficiencies. Overall, our study demonstrates the promise of full-scale TOEC systems to extract energy from low-grade heat and identifies key factors for performance optimization moving forward.

  6. Detailed energy saving performance analyses on thermal mass walls demonstrated in a zero energy house

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, L. [School of Architecture, Tianjin University, Tianjin 300072 (China); Hurt, R.; Correia, D.; Boehm, R. [Center for Energy Research, University of Nevada, Las Vegas, NV 89154 (United States)

    2009-03-15

    An insulated concrete wall system{sup 1}1 was used on exterior walls of a zero energy house. Its thermal functions were investigated using actual data in comparison to a conventional wood frame system. The internal wall temperature of massive systems changes more slowly than the conventional wall constructions, leading to a more stable indoor temperature. The Energy10 simulated equivalent R-value and DBMS of the mass walls under actual climate conditions are, respectively, 6.98 (m{sup 2} C)/W and 3.39. However, the simulated heating energy use was much lower for the massive walls while the cooling load was a little higher. Further investigation on the heat flux indicates that the heat actually is transferred inside all day and night, which results in a higher cooling energy consumption. A one-dimensional model further verified these analyses, and the calculated results are in good agreement with the actual data. We conclude that the thermal mass wall does have the ability to store heat during the daytime and release it back at night, but in desert climates with high 24-h ambient temperature and intense sunlight, more heat will be stored than can be transferred back outside at night. As a result, an increased cooling energy will be required. (author)

  7. 77 FR 1434 - Proposed Confidentiality Determinations for Data Elements Under the Mandatory Reporting of...

    Science.gov (United States)

    2012-01-10

    ... Fluorinated Gas Production....... 325120 Industrial gases manufacturing facilities. Electrical Equipment Use... Proposed Confidentiality Determinations for Data Elements Under the Mandatory Reporting of Greenhouse Gases...-proposes confidentiality determinations for the data elements under the Mandatory Greenhouse Gas Reporting...

  8. Energy Efficiency Investments in Public Facilities - Developing a Pilot Mechanism for Energy Performance Contracts (EPCs) in Russia

    Energy Technology Data Exchange (ETDEWEB)

    Evans, Meredydd; Roshchanka, Volha; Parker, Steven A.; Baranovskiy, Aleksandr

    2012-02-01

    : Russian public sector buildings tend to be very inefficient, which creates vast opportunities for savings. This report overviews the latest developments in the Russian legislation related to energy efficiency in the public sector, describes the major challenges the regulations pose, and proposes ways to overcome these challenges. Given Russia’s limited experience with energy performance contracts (EPCs), a pilot project can help test an implementation mechanism. This paper discusses how EPCs and other mechanisms can help harness energy savings opportunities in Russia in general, and thus, can be applicable to any Russian region.

  9. How not to argue against mandatory ethics review.

    Science.gov (United States)

    Hunter, David

    2013-08-01

    There is considerable controversy about the mandatory ethics review of research. This paper engages with the arguments offered by Murray Dyck and Gary Allen against mandatory review, namely, that this regulation fails to reach the standards that research ethics committees apply to research since it is harmful to the ethics of researchers, has little positive evidence base, leads to significant harms (through delaying valuable research) and distorts the nature of research. As these are commonplace arguments offered by researchers against regulation it is useful to assess their strength and the conclusion that they are taken to support, namely, that we ought to move back to a system of trust in researchers without compulsory regulation. Unfortunately, these arguments are at best weak and to some degree come into conflict in terms of supporting the desired conclusion.

  10. Influential Effects of Intrinsic-Extrinsic Incentive Factors on Management Performance in New Energy Enterprises.

    Science.gov (United States)

    Wang, Ping; Lu, Zhengnan; Sun, Jihong

    2018-02-08

    Background : New energy has become a key trend for global energy industry development. Talent plays a very critical role in the enhancement of new energy enterprise competitiveness. As a key component of talent, managers have been attracting more and more attention. The increase in job performance relies on, to a certain extent, incentive mechanism. Based on the Two-factor Theory, differences in influences and effects of different incentives on management performance have been checked in this paper from an empirical perspective. Methods : This paper selects the middle and low level managers in new energy enterprises as research samples and classifies the managers' performance into task performance, contextual performance and innovation performance. It uses manager performance questionnaires and intrinsic-extrinsic incentive factor questionnaires to investigate and study the effects and then uses Amos software to analyze the inner link between the intrinsic-extrinsic incentives and job performance. Results : Extrinsic incentives affect task performance and innovation performance positively. Intrinsic incentives impose active significant effects on task performance, contextual performance, and innovation performance. The intrinsic incentive plays a more important role than the extrinsic incentive. Conclusions : Both the intrinsic-extrinsic incentives affect manager performance positively and the intrinsic incentive plays a more important role than the extrinsic incentive. Several suggestions to management should be given based on these results.

  11. Influential Effects of Intrinsic-Extrinsic Incentive Factors on Management Performance in New Energy Enterprises

    Directory of Open Access Journals (Sweden)

    Ping Wang

    2018-02-01

    Full Text Available Background: New energy has become a key trend for global energy industry development. Talent plays a very critical role in the enhancement of new energy enterprise competitiveness. As a key component of talent, managers have been attracting more and more attention. The increase in job performance relies on, to a certain extent, incentive mechanism. Based on the Two-factor Theory, differences in influences and effects of different incentives on management performance have been checked in this paper from an empirical perspective. Methods: This paper selects the middle and low level managers in new energy enterprises as research samples and classifies the managers’ performance into task performance, contextual performance and innovation performance. It uses manager performance questionnaires and intrinsic-extrinsic incentive factor questionnaires to investigate and study the effects and then uses Amos software to analyze the inner link between the intrinsic-extrinsic incentives and job performance. Results: Extrinsic incentives affect task performance and innovation performance positively. Intrinsic incentives impose active significant effects on task performance, contextual performance, and innovation performance. The intrinsic incentive plays a more important role than the extrinsic incentive. Conclusions: Both the intrinsic-extrinsic incentives affect manager performance positively and the intrinsic incentive plays a more important role than the extrinsic incentive. Several suggestions to management should be given based on these results.

  12. Energy Efficiency Evaluation and Benchmarking of AFRL’s Condor High Performance Computer

    Science.gov (United States)

    2011-08-01

    PlayStation 3 nodes executing the HPL benchmark. When idle, the two PS3s consume 188.49 W on average. At peak HPL performance, the nodes draw an average of...AUG 2011 2. REPORT TYPE CONFERENCE PAPER (Post Print) 3. DATES COVERED (From - To) JAN 2011 – JUN 2011 4 . TITLE AND SUBTITLE ENERGY EFFICIENCY...the High Performance LINPACK (HPL) benchmark while also measuring the energy consumed to achieve such performance. Supercomputers are ranked by

  13. Data and analytics to inform energy retrofit of high performance buildings

    International Nuclear Information System (INIS)

    Hong, Tianzhen; Yang, Le; Hill, David; Feng, Wei

    2014-01-01

    Highlights: • High performance buildings can be retrofitted using measured data and analytics. • Data of energy use, systems operating and environmental conditions are needed. • An energy data model based on the ISO Standard 12655 is key for energy benchmarking. • Three types of analytics are used: energy profiling, benchmarking, and diagnostics. • The case study shows 20% of electricity can be saved by retrofit. - Abstract: Buildings consume more than one-third of the world’s primary energy. Reducing energy use in buildings with energy efficient technologies is feasible and also driven by energy policies such as energy benchmarking, disclosure, rating, and labeling in both the developed and developing countries. Current energy retrofits focus on the existing building stocks, especially older buildings, but the growing number of new high performance buildings built around the world raises a question that how these buildings perform and whether there are retrofit opportunities to further reduce their energy use. This is a new and unique problem for the building industry. Traditional energy audit or analysis methods are inadequate to look deep into the energy use of the high performance buildings. This study aims to tackle this problem with a new holistic approach powered by building performance data and analytics. First, three types of measured data are introduced, including the time series energy use, building systems operating conditions, and indoor and outdoor environmental parameters. An energy data model based on the ISO Standard 12655 is used to represent the energy use in buildings in a three-level hierarchy. Secondly, a suite of analytics were proposed to analyze energy use and to identify retrofit measures for high performance buildings. The data-driven analytics are based on monitored data at short time intervals, and cover three levels of analysis – energy profiling, benchmarking and diagnostics. Thirdly, the analytics were applied to a high

  14. Building Energy and Cost Performance: An Analysis of Thirty Melbourne Case Studies

    Directory of Open Access Journals (Sweden)

    Yu Lay Langston

    2012-11-01

    Full Text Available This study investigates the energy and cost performance of thirty recent buildings in Melbourne, Australia. Commonly, building design decisions are based on issues pertaining to construction cost, and consideration of energy performance is made only within the context of the initial project budget. Even where energy is elevated to more importance, operating energy is seen as the focus and embodied energy is nearly always ignored. For the first time, a large sample of buildings has been assembled and analyzed to improve the understanding of both energy and cost performance over their full life cycle, which formed the basis of a wider doctoral study into the inherent relationship between energy and cost. The aim of this paper is to report on typical values for embodied energy, operating energy, capital cost and operating cost per square metre for a range of building functional types investigated in this research. The conclusion is that energy and cost have quite different profiles across projects, and yet the mean GJ/m2 or cost/m2 have relatively low coefficients of variation and therefore may be useful as benchmarks of typical building performance.  

  15. The comparison of the energy performance of hotel buildings using PROMETHEE decision-making method

    Directory of Open Access Journals (Sweden)

    Vujosevic Milica L.

    2016-01-01

    Full Text Available Annual energy performance of the atrium type hotel buildings in Belgrade climate conditions are analysed in this paper. The objective is to examine the impact of the atrium on the hotel building’s energy needs for space heating and cooling, thus establishing the best design among four proposed alternatives of the hotels with atrium. The energy performance results are obtained using EnergyPlus simulation engine, taking into account Belgrade climate data and thermal comfort parameters. The selected results are compared and the hotels are ranked according to certain criteria. Decision-making process that resulted in the ranking of the proposed alternatives is conducted using PROMETHEE method and Borda model. The methodological approach in this research includes the creation of a hypothetical model of an atrium type hotel building, numerical simulation of energy performances of four design alternatives of the hotel building with an atrium, comparative analysis of the obtained results and ranking of the proposed alternatives from the building’s energy performance perspective. The main task of the analysis is to examine the influence of the atrium, with both its shape and position, on the energy performance of the hotel building. Based on the results of the research it can be to determine the most energy efficient model of the hotel building with atrium for Belgrade climate condition areas. [Projekat Ministarstva nauke Republike Srbije: Spatial, Environmental, Energy and Social aspects of the Developing Settlements and Climate Change - Mutual Impacts

  16. Characterisation of representative building typologies for social housing projects in Brazil and its energy performance

    International Nuclear Information System (INIS)

    Triana, Maria Andrea; Lamberts, Roberto; Sassi, Paola

    2015-01-01

    In Brazil the housing deficit is around 5.5 million houses. To address this need, the government created a programme called “My house, My life”. The main subsidies of the programme are for families earning up to three times the minimum wage. In order to formulate strategies for more energy efficiency buildings, it is necessary to understand the thermal and energy performance of what is being built. This article defines representative projects for typologies being built in the Brazilian social housing sector through the analysis of 108 projects considering two groups of income levels and investigates the thermal and energy performance of the representative projects in relation to the Regulation for Energy Efficiency Labelling of Residential Buildings in Brazil for two bioclimatic zones. Five representative building models were defined. Considering the most common features found on the sample, the study suggests the importance of addresing energy efficiency measures on the sector since current building techniques for social housing shows a tendency towards a low performance in relation to the thermal and energy performance criteria of the Energy Labelling especially for lower income projects. This provides a basis for future policy and allows for more in depth studies within the sector. - Highlights: • Characterisation of representative typologies built for social housing in Brazil. • More recurrent building physics characteristics considered. • Energy efficiency and thermal performance of Brazilian social housing analysed. • Regulation for Energy Efficiency Labelling of Residential Buildings in Brazil used for analysis.

  17. Does Mandatory IFRS Adoption Improve the Information Environment?

    OpenAIRE

    Horton, Joanne; Serafeim, Georgios; Serafeim, Ioanna

    2012-01-01

    More than 120 countries require or permit the use of International Financial Reporting Standards (‘IFRS’) by publicly listed companies on the basis of higher information quality and accounting comparability from IFRS application. However, the empirical evidence about these presumed benefits are often conflicting and fail to separate between information quality and comparability. In this paper we examine the effect of mandatory IFRS adoption on firms’ information environment. We find that afte...

  18. Mandatory Corporate Social Responsibility Reporting in the EU

    DEFF Research Database (Denmark)

    Szabó, Dániel Gergely

    , as well as other dedicated reporting types. The author investigates what legal framework underpins these disclosure types; to what extent these instruments mandate the disclosure of non-financial information; and if they have potential to expand their non-financial disclosure requirements. The findings...... suggest that mandatory nonfinancial reporting is less developed than expected. It further recommends more narrow and elaborate disclosure obligations to achieve higher transparency in CSR matters....

  19. Is active management of mandatory pension funds in Croatia creating value for second pillar fund members?

    Directory of Open Access Journals (Sweden)

    Petar-Pierre Matek

    2015-09-01

    Full Text Available This paper analyses Croatian mandatory pension funds’ investment returns during the 2005-2014 period using performance attribution methodology. Results from active investment management are compared to a long-term policy return. Such analysis is essential to shed light on the contribution of active portfolio management in the second pillar pension scheme. Evidence suggests that in the period analysed portfolio managers have added value through active management decisions. In addition, we determined the sources of portfolio return by breaking down active return into policy, tactical asset allocation and security selection effect.

  20. Medicine, psychiatry and euthanasia: an argument against mandatory psychiatric review.

    Science.gov (United States)

    Parker, M

    2000-04-01

    The paper critically appraises the argument that requests for active assistance to die should be subject to mandatory psychiatric assessment. The argument for mandatory psychiatric assessment is usually supported by an appeal to the need for safeguards against errors and omissions in both the diagnosis of psychiatric conditions affecting the terminally ill and the exploration of the meanings of their requests. This intuitively appealing view is challenged through a broader analysis which examines connections between medicine's traditional adherence to the moral distinction between acts and omissions and the following issues: the historical relationship between medical practice and dying, the recent development of research into treatment-withdrawal decisions, the scientific status of psychiatry, the logic of rationality and decision-making competence. The analysis reveals a number of hitherto unexamined and unacknowledged influences which would make psychiatric review of requests for assisted death a much less objective and impartial process than is assumed. Mandatory psychiatric review is an instance of the medicalisation of death and dying which could abridge the freedom of certain individuals to make decisions about their deaths.

  1. 7 CFR 59.303 - Mandatory reporting of lamb carcasses and boxed lamb.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Mandatory reporting of lamb carcasses and boxed lamb... INSPECTION ACT (CONTINUED) LIVESTOCK MANDATORY REPORTING Lamb Reporting § 59.303 Mandatory reporting of lamb carcasses and boxed lamb. (a) Daily reporting of lamb carcass transactions. The corporate officers or...

  2. 7 CFR 59.102 - Mandatory daily reporting for cows and bulls.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 3 2010-01-01 2010-01-01 false Mandatory daily reporting for cows and bulls. 59.102... (CONTINUED) LIVESTOCK MANDATORY REPORTING Cattle Reporting § 59.102 Mandatory daily reporting for cows and bulls. (a) In General. The corporate officers or officially designated representatives of each cow and...

  3. 29 CFR Appendix III to Part 1918 - The Mechanics of Conventional Cargo Gear (Non-mandatory)

    Science.gov (United States)

    2010-07-01

    ... 29 Labor 7 2010-07-01 2010-07-01 false The Mechanics of Conventional Cargo Gear (Non-mandatory.... 1918, App. III Appendix III to Part 1918—The Mechanics of Conventional Cargo Gear (Non-mandatory) Note: This appendix is non-mandatory and provides an explanation of the mechanics in the correct spotting of...

  4. Renewable energy powered membrane technology. 2. The effect of energy fluctuations on performance of a photovoltaic hybrid membrane system

    OpenAIRE

    Richards, B.S.; Capão, D.P.S.; Schäfer, Andrea

    2008-01-01

    This paper reports on the performance fluctuations during the operation of a batteryless hybrid ultrafiltration-nanofiltration/reverse osmosis (UF-NF/RO) membrane desalination system powered by photovoltaics treating brackish groundwater in outback Australia. The renewable energy powered membrane (RE-membrane) system is designed to supply clean drinking water to a remote community of about 50 inhabitants. The performance of the RE-membrane system over four different solar days is summarized u...

  5. Experimental investigation on the hydrodynamic performance of a wave energy converter

    Science.gov (United States)

    Zheng, Xiong-bo; Ma, Yong; Zhang, Liang; Jiang, Jin; Liu, Heng-xu

    2017-06-01

    Wave energy is an important type of marine renewable energy. A wave energy converter (WEC) moored with two floating bodies was developed in the present study. To analyze the dynamic performance of the WEC, an experimental device was designed and tested in a tank. The experiment focused on the factors which impact the motion and energy conversion performance of the WEC. Dynamic performance was evaluated by the relative displacements and velocities of the oscillator and carrier which served as the floating bodies of WEC. Four factors were tested, i.e. wave height, wave period, power take-off (PTO) damping, and mass ratio ( R M) of the oscillator and carrier. Experimental results show that these factors greatly affect the energy conversion performance, especially when the wave period matches R M and PTO damping. According to the results, we conclude that: (a) the maximization of the relative displacements and velocities leads to the maximization of the energy conversion efficiency; (b) the larger the wave height, the higher the energy conversion efficiency will be; (c) the relationships of energy conversion efficiency with wave period, PTO damping, and R M are nonlinear, but the maximum efficiency is obtained when these three factors are optimally matched. Experimental results demonstrated that the energy conversion efficiency reached the peak at 28.62% when the wave height was 120 mm, wave period was 1.0 s, R M was 0.21, and the PTO damping was corresponding to the resistance of 100 Ω.

  6. Building envelope influence on the annual energy performance in office buildings

    Directory of Open Access Journals (Sweden)

    Harmati Norbert L.

    2016-01-01

    Full Text Available The objective of the research is to determine the quantitative influence of building envelope on the annual heating and cooling energy demand in office buildings demonstrated on a reference office-tower building located in Novi Sad, Serbia. The investigation intended to find preferable and applicable solutions for energy performance improvement in currently inefficient office buildings. A comparative and evaluative analysis was performed among the heating energy expenses and simulated values from the multi-zone model designed in EnergyPlus engine. The research determines an improved window to wall ratio using dynamic daylight simulation and presents the influence of glazing parameters (U-value, Solar heat gain coefficient - SHGC on the annual energy performance. Findings presented window to wall ratio reduction down to 30% and point out the significance of the SHGC parameter on the overall energy performance of buildings with high internal loads. The calculation of the air-ventilation energy demand according to EN 15251 is included respectively. Results offer effective methods for energy performance improvement in temperate climate conditions.

  7. Harvested Energy Prediction Schemes for Wireless Sensor Networks: Performance Evaluation and Enhancements

    Directory of Open Access Journals (Sweden)

    Muhammad

    2017-01-01

    Full Text Available We review harvested energy prediction schemes to be used in wireless sensor networks and explore the relative merits of landmark solutions. We propose enhancements to the well-known Profile-Energy (Pro-Energy model, the so-called Improved Profile-Energy (IPro-Energy, and compare its performance with Accurate Solar Irradiance Prediction Model (ASIM, Pro-Energy, and Weather Conditioned Moving Average (WCMA. The performance metrics considered are the prediction accuracy and the execution time which measure the implementation complexity. In addition, the effectiveness of the considered models, when integrated in an energy management scheme, is also investigated in terms of the achieved throughput and the energy consumption. Both solar irradiance and wind power datasets are used for the evaluation study. Our results indicate that the proposed IPro-Energy scheme outperforms the other candidate models in terms of the prediction accuracy achieved by up to 78% for short term predictions and 50% for medium term prediction horizons. For long term predictions, its prediction accuracy is comparable to the Pro-Energy model but outperforms the other models by up to 64%. In addition, the IPro scheme is able to achieve the highest throughput when integrated in the developed energy management scheme. Finally, the ASIM scheme reports the smallest implementation complexity.

  8. Energy performance indicators of wastewater treatment: a field study with 17 Portuguese plants.

    Science.gov (United States)

    Silva, Catarina; Rosa, Maria João

    2015-01-01

    The energy costs usually represent the second largest part of the running costs of a wastewater treatment plant (WWTP). It is therefore crucial to increase the energy efficiency of these infrastructures and to implement energy management systems, where quantitative performance metrics, such as performance indicators (PIs), play a key role. This paper presents energy PIs which cover the unit energy consumption, production, net use from external sources and costs, and the results used to validate them and derive their reference values. The results of a field study with 17 Portuguese WWTPs (5-year period) were consistent with the results obtained through an international literature survey on the two key parcels of the energy balance--consumption and production. The unit energy consumption showed an overall inverse relation with the volume treated, and the reference values reflect this relation for trickling filters and for activated sludge systems (conventional, with coagulation/filtration (C/F) and with nitrification and C/F). The reference values of electrical energy production were derived from the methane generation potential (converted to electrical energy) and literature data, whereas those of energy net use were obtained by the difference between the energy consumption and production.

  9. Profiting from negawatts: Reducing absolute consumption and emissions through a performance-based energy economy

    International Nuclear Information System (INIS)

    Steinberger, Julia K.; Niel, Johan van; Bourg, Dominique

    2009-01-01

    Current energy and GHG emissions policies either focus directly on emissions or promote renewable production and the implementation of specific efficiency measures. Meanwhile, the fundamental structure of the energy market based on profits through energy throughput remains largely unchallenged. This policy oversight prevents the transition to an energy economy in which profits are based on energy services delivered at the lowest energy cost: a performance-based energy economy (PBEE). The PBEE applies the combined concepts of the performance economy and energy services to the energy sector. Energy Service Companies (ESCOs) are discussed as an example of PBEE practices. The implications for energy suppliers and consumers as well as the conditions for PBEE diffusion and consequences for technological change are also explored. The expected environmental, social and economic benefits are described. However, absolute consumption and emissions reductions may prove elusive due to the rebound effect. In order to forestall rebound-led increases, complementary policy measures likely to lead to absolute reductions are required

  10. Profiting from negawatts. Reducing absolute consumption and emissions through a performance-based energy economy

    Energy Technology Data Exchange (ETDEWEB)

    Steinberger, Julia K. [IPTEH, Quartier Sorge-Bat. Amphipole, University of Lausanne, CH-1015-Lausanne (Switzerland); Institute of Social Ecology, Klagenfurt University, Schottenfeldg. 29, A-1070 Vienna (Austria); van Niel, Johan [IPTEH, Quartier Sorge-Bat. Amphipole, University of Lausanne, CH-1015-Lausanne (Switzerland); CREIDD, University of Technology of Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes Cedex (France); Bourg, Dominique [IPTEH, Quartier Sorge-Bat. Amphipole, University of Lausanne, CH-1015-Lausanne (Switzerland)

    2009-01-15

    Current energy and GHG emissions policies either focus directly on emissions or promote renewable production and the implementation of specific efficiency measures. Meanwhile, the fundamental structure of the energy market based on profits through energy throughput remains largely unchallenged. This policy oversight prevents the transition to an energy economy in which profits are based on energy services delivered at the lowest energy cost: a performance-based energy economy (PBEE). The PBEE applies the combined concepts of the performance economy and energy services to the energy sector. Energy Service Companies (ESCOs) are discussed as an example of PBEE practices. The implications for energy suppliers and consumers as well as the conditions for PBEE diffusion and consequences for technological change are also explored. The expected environmental, social and economic benefits are described. However, absolute consumption and emissions reductions may prove elusive due to the rebound effect. In order to forestall rebound-led increases, complementary policy measures likely to lead to absolute reductions are required. (author)

  11. Profiting from negawatts: Reducing absolute consumption and emissions through a performance-based energy economy

    Energy Technology Data Exchange (ETDEWEB)

    Steinberger, Julia K. [IPTEH, Quartier Sorge-Bat. Amphipole, University of Lausanne, CH-1015-Lausanne (Switzerland); Institute of Social Ecology, Klagenfurt University, Schottenfeldg. 29, A-1070 Vienna (Austria)], E-mail: julia.steinberger@uni-klu.ac.at; Niel, Johan van [IPTEH, Quartier Sorge-Bat. Amphipole, University of Lausanne, CH-1015-Lausanne (Switzerland); CREIDD, University of Technology of Troyes, 12 rue Marie Curie, BP 2060, 10010 Troyes Cedex (France); Bourg, Dominique [IPTEH, Quartier Sorge-Bat. Amphipole, University of Lausanne, CH-1015-Lausanne (Switzerland)

    2009-01-15

    Current energy and GHG emissions policies either focus directly on emissions or promote renewable production and the implementation of specific efficiency measures. Meanwhile, the fundamental structure of the energy market based on profits through energy throughput remains largely unchallenged. This policy oversight prevents the transition to an energy economy in which profits are based on energy services delivered at the lowest energy cost: a performance-based energy economy (PBEE). The PBEE applies the combined concepts of the performance economy and energy services to the energy sector. Energy Service Companies (ESCOs) are discussed as an example of PBEE practices. The implications for energy suppliers and consumers as well as the conditions for PBEE diffusion and consequences for technological change are also explored. The expected environmental, social and economic benefits are described. However, absolute consumption and emissions reductions may prove elusive due to the rebound effect. In order to forestall rebound-led increases, complementary policy measures likely to lead to absolute reductions are required.

  12. Success factors of energy performance contracting (EPC) for sustainable building energy efficiency retrofit (BEER) of hotel buildings in China

    International Nuclear Information System (INIS)

    Xu Pengpeng; Chan, Edwin Hon-Wan; Queena Kun Qian

    2011-01-01

    Hotel building is a type of high-energy-consuming building and most existing hotel buildings need energy efficiency improvement in China. Energy performance contracting (EPC) is considered a win-win mechanism to organize building energy efficiency retrofit (BEER) project. However, EPC mechanism has been introduced into China relatively recently and many EPCs have not been successful in building energy efficiency retrofit projects. This research aims to develop a set of critical success factors (CSFs) of EPC for sustainable energy efficiency retrofit (BEER) of hotel buildings in China. Semi-structured interviews and a questionnaire survey with practitioners and other professionals were conducted. The findings reveal the relative importance of the 21 number of identified success factors. In order to explore the underlying relationship among the identified critical success factors (CSFs), factor analysis method was adopted for further investigation, which leads to grouping the 21 identified CSFs into six clusters. These are (1) project organization process, (2) EPC project financing for hotel retrofit, (3) knowledge and innovation of EPC, sustainable development (SD), and M and V, (4) implementation of sustainable development strategy, (5) contractual arrangement, and (6) external economic environment. Finally, several relevant policies were proposed to implement EPC successfully in sustainable BEER in hotel buildings. - Highlights: → EPC is a win-win mechanism to organize building energy efficiency retrofit project. → CSFs of EPC mechanism for sustainable BEER of hotel building in China are examined. → Six clusters are extracted from 21 identified CSFs based on factor analysis.

  13. The impact of energy performance certificates: A survey of German home owners

    International Nuclear Information System (INIS)

    Amecke, Hermann

    2012-01-01

    The building sector accounts for about 40% of the final energy consumption in Germany. At the same time, the sector is regarded as one of the most cost-effective options for saving CO 2 emissions. To target this potential, the European Union introduced energy performance certificates (EPC). EPCs should provide clear information about the energy performance of buildings to building purchasers, owners and tenants. This study analyses, in how far EPCs have helped purchasers of owner-occupied dwellings in Germany to incorporate energy efficiency in their purchasing decisions. The results suggest that the effectiveness of EPCs is limited. Main reasons are first, that the certificates are not helpful for understanding the financial implications of energy efficiency. Second, EPCs are not viewed for most buildings due to their legal status. Third, energy efficiency is only a minor purchasing criterion for dwelling purchases. The results of the study however also point to the potential of EPCs, as these barriers can be removed. From 2013 onwards the use of the EPC will be increased due to the new EU Energy Performance of Buildings Directive (EPBD). Changes to the design of the EPC could further increase the importance of energy performance certificates and of energy efficiency. - Highlights: ► Study examines impact of EU energy performance certificate on German housing market. ► Low impact of EPC on purchasing decisions found. ► Reasons are limitations in design, legal status, importance of energy efficiency. ► Study is relevant because of low previous coverage and because of update of directive.

  14. Capacity market design and renewable energy: Performance incentives, qualifying capacity, and demand curves

    Energy Technology Data Exchange (ETDEWEB)

    Botterud, Audun; Levin, Todd; Byers, Conleigh

    2018-01-01

    A review of capacity markets in the United States in the context of increasing levels of variable renewable energy finds substantial differences with respect to incentives for operational performance, methods to calculate qualifying capacity for variable renewable energy and energy storage, and demand curves for capacity. The review also reveals large differences in historical capacity market clearing prices. The authors conclude that electricity market design must continue to evolve to achieve cost-effective policies for resource adequacy.

  15. Republic of Korea Reduction of Financing Barriers for Energy Savings Performance Contracts

    Energy Technology Data Exchange (ETDEWEB)

    Howard, D. L.

    2005-11-01

    This paper discusses the findings developed for strengthening the role of performance contracting in improving energy efficiency in the Republic of Korea. The U.S. Environmental Protection Agency (EPA) sponsored development of this paper by the National Renewable Energy Laboratory (NREL), as a part of the Korean-U.S. Climate Technology Partnerships (CTP) program. The results and recommendations outlined in this paper together with other efforts are designed to assist other countries striving to improve their efficient use of energy.

  16. Mandatory and Self-citation; Types, Reasons, Their Benefits and Disadvantages.

    Science.gov (United States)

    Hemmat Esfe, Mohammad; Wongwises, Somchai; Asadi, Amin; Karimipour, Arash; Akbari, Mohammad

    2015-12-01

    This paper defines and discusses two important types of citations, self-citation and mandatory citation, in engineering journals. Citation can be classified in three categories: optional; semi-mandatory; and mandatory. There are some negative and positive impacts for the authors' paper and journals' reputation if mandatory citation of a paper or set of papers is requested. These effects can be different based on the recommended papers for citing in the new research. Mandatory citation has various types discussed in this paper. Self-citation and its reasons and impacts are also discussed in the present study.

  17. High energy density additives for Hybrid Fuel Rockets to Improve Performance and Enhance Safety

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose a conceptual study of prototype strained hydrocarbon molecules as high energy density additives for hybrid rocket fuels to boost the performance of these...

  18. Does energy and CO_2 emissions performance of China benefit from regional integration?

    International Nuclear Information System (INIS)

    Li, Jianglong; Lin, Boqiang

    2017-01-01

    Low energy and carbon efficiency and widespread market segmentation are two stylized facts of China's regional economies. This paper evaluates energy and CO_2 emissions performance using a newly developed non-radial directional distance function, and China's regional integration is investigated using a price approach. The study points to evidence that: (1) most provinces do not perform efficiently in terms of energy use and CO_2 emissions with performance gaps among regions becoming larger, indicating regional segmentation; (2) magnitude of regional integration has increased dramatically, while China's eastern provinces are less integrated in domestic side due to their convenience to international openness; (3) regional integration has significant and robust positive effects on energy and CO_2 emissions performance with over 70% of effects coming from artificial barriers, rather than geographical distance; (4) international openness is also beneficial for promoting energy and CO_2 emissions performance, but cannot substitute for regional integration because of China's specialization in energy-intensive manufacturing in the global economy. Based on the empirical findings, we suggest that central government should continue to encourage regional integration given that local governments have incentives to fragment because it is a way of promoting energy and CO_2 emissions performance and stimulating economy at the same time. - Highlights: • NDDF method is applied to evaluate China's regional energy and carbon performance. • Difficulties in identifying NDDF using parametric approach are discussed. • Panel data of China's regional integration using the price approach is constructed. • Local protectionism is particularly identified by filtering effects of geography. • World trade cannot substitute domestic integration for improving energy efficiency.

  19. Improvements in the energy resolution and high-count-rate performance of bismuth germanate

    International Nuclear Information System (INIS)

    Koehler, P.E.; Wender, S.A.; Kapustinsky, J.S.

    1985-01-01

    Several methods for improving the energy resolution of bismuth germanate (BGO) have been investigated. It is shown that some of these methods resulted in a substantial improvement in the energy resolution. In addition, a method to improve the performance of BGO at high counting rates has been systematically studied. The results of this study are presented and discussed

  20. Using EnergyPlus to Perform Dehumidification Analysis on Building America Homes

    Energy Technology Data Exchange (ETDEWEB)

    Fang, Xia [National Renewable Energy Lab. (NREL), Golden, CO (United States); Winkler, Jon [National Renewable Energy Lab. (NREL), Golden, CO (United States); Christensen, Dane [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2011-03-01

    This study used EnergyPlus to investigate humidity issues on a typical mid-1990s reference home, a 2006 International Energy Conservation Code home, and a high-performance home in a hot-humid climate; the study confirmed that supplemental dehumidification should be provided to maintain space relative humidity below 60% in a hot-humid climate.

  1. Development of an Enhanced Payback Function for the Superior Energy Performance Program

    Energy Technology Data Exchange (ETDEWEB)

    Therkelsen, Peter; Rao, Prakash; McKane, Aimee; Sabouni, Ridah; Sheihing, Paul

    2015-08-03

    The U.S. DOE Superior Energy Performance (SEP) program provides recognition to industrial and commercial facilities that achieve certification to the ISO 50001 energy management system standard and third party verification of energy performance improvements. Over 50 industrial facilities are participating and 28 facilities have been certified in the SEP program. These facilities find value in the robust, data driven energy performance improvement result that the SEP program delivers. Previous analysis of SEP certified facility data demonstrated the cost effectiveness of SEP and identified internal staff time to be the largest cost component related to SEP implementation and certification. This paper analyzes previously reported and newly collected data of costs and benefits associated with the implementation of an ISO 50001 and SEP certification. By disaggregating “sunk energy management system (EnMS) labor costs”, this analysis results in a more accurate and detailed understanding of the costs and benefits of SEP participation. SEP is shown to significantly improve and sustain energy performance and energy cost savings, resulting in a highly attractive return on investment. To illustrate these results, a payback function has been developed and is presented. On average facilities with annual energy spend greater than $2M can expect to implement SEP with a payback of less than 1.5 years. Finally, this paper also observes and details decreasing facility costs associated with implementing ISO 50001 and certifying to the SEP program, as the program has improved from pilot, to demonstration, to full launch.

  2. Physiological performance of plaice Pleuronectes platessa (L.): from Static to Dynamic Energy Budgets.

    NARCIS (Netherlands)

    v.d. Veer, H.; Cardoso, J.F.M.F.; Peck, M.A.; Kooijman, S.A.L.M.

    2009-01-01

    In the present study, various body size scaling relationships describing the physiological performance of plaice Pleuronectes platessa (L.) were derived using a dynamic energy budget (DEB) model and compared with allometric relationships derived from a static energy budget (SEB) model. Results

  3. Introducing mandatory standards for select household appliances in Lebanon: A cost-benefit analysis

    International Nuclear Information System (INIS)

    Ruble, Isabella; Karaki, Sami

    2013-01-01

    Lebanon's energy sector crisis leads to a lack of access to uninterrupted, basic modern electricity services that affects all sectors of the economy. Energy conservation measures are nearly inexistent yet they can potentially lead to substantial reductions in energy demand growth, environmental damages and public expenditures. This paper presents an analysis of the costs and benefits associated with the introduction of mandatory standards for energy efficiency for four different household appliances (refrigerator/freezers, AC split units, washing machines and lighting) over the period 2013–2027. Our results show potential savings in electricity consumption reaching 2054 GW h annually in 2027 as well as a reduction of subsidies paid to the public utility of 3.6 billion USD in 2027 while CO 2 emissions avoided amount to 8.9 million tons over the period of analysis. Furthermore, we propose a financially attractive refrigerator/freezer replacement program for low income households. If this program would cover all existing low-income households in 2013, the savings in electricity consumption would lead to a reduction in subsidies of 9 billion USD (NPV) over the period 2013–2027, while full funding for this program would cost the government 223.8 million USD. This program would thereby benefit consumers, the government and further economic development. - Highlights: ► We model the effect of mandatory appliance standards on electricity consumption. ► We present a refrigerator replacement program contributing to economic development. ► We show that economic efficiency favors the introduction of standards for appliances.

  4. Record completeness and data concordance in an anesthesia information management system using context-sensitive mandatory data-entry fields.

    Science.gov (United States)

    Avidan, Alexander; Weissman, Charles

    2012-03-01

    Use of an anesthesia information management system (AIMS) does not insure record completeness and data accuracy. Mandatory data-entry fields can be used to assure data completeness. However, they are not suited for data that is mandatory depending on the clinical situation (context sensitive). For example, information on equal breath sounds should be mandatory with tracheal intubation, but not with mask ventilation. It was hypothesized that employing context-sensitive mandatory data-entry fields can insure high data-completeness and accuracy while maintaining usability. A commercial off-the-shelf AIMS was enhanced using its built-in VBScript programming tool to build event-driven forms with context-sensitive mandatory data-entry fields. One year after introduction of the system, all anesthesia records were reviewed for data completeness. Data concordance, used as a proxy for accuracy, was evaluated using verifiable age-related data. Additionally, an anonymous satisfaction survey on general acceptance and usability of the AIMS was performed. During the initial 12 months of AIMS use, 12,241 (99.6%) of 12,290 anesthesia records had complete data. Concordances of entered data (weight, size of tracheal tubes, laryngoscopy blades and intravenous catheters) with patients' ages were 98.7-99.9%. The AIMS implementation was deemed successful by 98% of the anesthesiologists. Users rated the AIMS usability in general as very good and the data-entry forms in particular as comfortable. Due to the complexity and the high costs of implementation of an anesthesia information management system it was not possible to compare various system designs (for example with or without context-sensitive mandatory data entry-fields). Therefore, it is possible that a different or simpler design would have yielded the same or even better results. This refers also to the evaluation of usability, since users did not have the opportunity to work with different design approaches or even different

  5. Impact of window selection on the energy performance of residential buildings in South Korea

    International Nuclear Information System (INIS)

    Ihm, Pyeongchan; Park, Lyool; Krarti, Moncef; Seo, Donghyun

    2012-01-01

    With rapidly increasing energy consumption attributed to residential buildings in South Korea, there is a need to update requirements of the building energy code in order to improve the energy performance of buildings. This paper provides some guidelines to improve the building energy code to better select glazing types that minimize total energy use of residential buildings in Korea. In particular, detailed energy simulation analyses coupled with economical and environmental assessments are carried out to assess the thermal, economical, and environmental impacts of glazing thermal characteristics as well as window sizes associated with housing units in various representative climates within South Korea. The results of the analyses have clearly indicated that selecting glazing with low solar heat gain coefficient is highly beneficial especially for large windows and for mild climates. In particular, it is found that using any double-pane low-e glazing would provide better performance for windows in residential buildings than the clear double-pane glazing, currently required by the Korean building energy code. - Highlights: ► Results show that windows can be energy neutral for residential buildings. ► In Korea, double-pane low-e glazing would provide better energy performance. ► Double low-e clear filled with argon gas glazing is the most cost-effective.

  6. Strategic design of cost savings guarantee in energy performance contracting under uncertainty

    International Nuclear Information System (INIS)

    Deng, Qianli; Jiang, Xianglin; Cui, Qingbin; Zhang, Limao

    2015-01-01

    Highlights: • A methodology is proposed to assist Energy Service Companies to maintain competitiveness in winning bids. • Uncertainties within the energy cost savings are modeled stochastically using the Monte-Carlo simulation. • A strategic energy savings guarantee design curve is derived, where all points return as appropriate guarantees. • A campus case is presented to demonstrate the applicability for finding appropriate guaranteed savings value. - Abstract: Among the key barriers to profit in Energy Performance Contracting (EPC) are uncertainties about attaining the realized energy cost savings and potential disputes over the guaranteed cost savings. In this paper, a methodology has been proposed to assist the Energy Service Company (ESCO): (1) to evaluate the risk threshold if the guarantee has already been made, and (2) to determine the guarantee design, if the guarantee has not been made yet, that not only promises the ESCO’s profitability from EPC but also maintains its competitiveness to win the bid. Uncertainties within the energy cost savings are modeled stochastically using Monte-Carlo simulation, taking both the energy price fluctuation and the facility performance variability into account. Based on that, a strategic energy savings guarantee design curve is derived, that all the points on it would return as appropriate guarantees. Finally, a campus case is presented to demonstrate the applicability for finding the appropriate guaranteed savings value. This method is also worth popularizing in similar performance-based projects

  7. Cooling performance and energy saving of a compression-absorption refrigeration system assisted by geothermal energy

    International Nuclear Information System (INIS)

    Kairouani, L.; Nehdi, E.

    2006-01-01

    The objectives of this paper are to develop a novel combined refrigeration system, and to discuss the thermodynamic analysis of the cycle and the feasibility of its practical development. The aim of this work was to study the possibility of using geothermal energy to supply vapour absorption system cascaded with conventional compression system. Three working fluids (R717, R22, and R134a) are selected for the conventional compression system and the ammonia-water pair for the absorption system. The geothermal temperature source in the range 343-349 K supplies a generator operating at 335 K. Results show that the COP of a combined system is significantly higher than that of a single stage refrigeration system. It is found that the COP can be improved by 37-54%, compared with the conventional cycle, under the same operating conditions, that is an evaporation temperature at 263 K and a condensation temperature of 308 K. For industrial refrigeration, the proposed system constitutes an alternative solution for reducing energy consumption and greenhouse gas emissions

  8. Relational energy at work: Implications for job engagement and job performance.

    Science.gov (United States)

    Owens, Bradley P; Baker, Wayne E; Sumpter, Dana McDaniel; Cameron, Kim S

    2016-01-01

    Energy is emerging as a topic of importance to organizations, yet we have little understanding of how energy can be useful at an interpersonal level toward achieving workplace goals. We present the results of 4 studies aimed at developing, validating, and testing the relational energy construct. In Study 1, we report qualitative insights from 64 individuals about the experience and functioning of relational energy in the workplace. Study 2 draws from 3 employee samples to conduct exploratory and confirmatory factor analyses on a measure of relational energy, differentiating relational energy from related constructs. To test the predictive validity of the new relational energy scale, Study 3 comprises data from employees rating the level of relational energy they experienced during interactions with their leaders in a health services context. Results showed that relational energy employees experienced with their leaders at Time 1 predicted job engagement at Time 2 (1 month later), while controlling for the competing construct of perceived social support. Study 4 shows further differentiation of relational energy from leader-member exchange (LMX), replicates the positive relationship between relational energy (Time 1) and job engagement (Time 2), and shows that relational energy is positively associated with employee job performance (Time 3) through the mechanism of job engagement. We discuss the theoretical implications of our findings and highlight areas for future research. (c) 2016 APA, all rights reserved).

  9. Performance analysis of different ORC configurations for thermal energy and LNG cold energy hybrid power generation system

    Science.gov (United States)

    Sun, Zhixin; Wang, Feng; Wang, Shujia; Xu, Fuquan; Lin, Kui

    2017-01-01

    This paper presents a thermal energy and Liquefied natural gas (LNG) cold energy hybrid power generation system. Performances of four different Organic Rankine cycle (ORC) configurations (the basic, the regenerative, the reheat and the regenerative-reheat ORCs) are studied based on the first and the second law of thermodynamics. Dry organic fluid R245fa is selected as the typical working fluid. Parameter analysis is also conducted in this paper. The results show that regeneration could not increase the thermal efficiency of the thermal and cold energy hybrid power generation system. ORC with the reheat process could produce more specific net power output but it may also reduce the system thermal efficiency. The basic and the regenerative ORCs produce higher thermal efficiency while the regenerative-reheat ORC performs best in the exergy efficiency. A preheater is necessary for the thermal and cold energy hybrid power generation system. And due to the presence of the preheater, there will be a step change of the system performance as the turbine inlet pressure rises.

  10. Benchmarking the energy performance of office buildings: A data envelopment analysis approach

    Directory of Open Access Journals (Sweden)

    Molinos-Senante, María

    2016-12-01

    Full Text Available The achievement of energy efficiency in buildings is an important challenge facing both developed and developing countries. Very few papers have assessed the energy efficiency of office buildings using real data. To overcome this limitation, this paper proposes an energy efficiency index for buildings having a large window-to-wall ratio, and uses this index to identify the main architectural factors affecting energy performance. This paper assesses, for the first time, the energy performances of 34 office buildings in Santiago, Chile, by using data envelopment analysis. Overall energy efficiency is decomposed into two indices: the architectural energy efficiency index, and the management energy efficiency index. This decomposition is an essential step in identifying the main drivers of energy inefficiency and designing measures for improvement. Office buildings examined here have significant room for improving their energy efficiencies, saving operational costs and reducing greenhouse gas emissions. The methodology and results of this study will be of great interest to building managers and policymakers seeking to increase the sustainability of cities.

  11. An energy performance assessment for indoor environmental quality (IEQ) acceptance in air-conditioned offices

    International Nuclear Information System (INIS)

    Wong, L.T.; Mui, K.W.

    2009-01-01

    Maintaining an acceptable indoor environmental quality (IEQ) for air-conditioned office buildings consumes a considerable amount of thermal energy. This study correlates thermal energy consumption with the overall occupant acceptance of IEQ in some air-conditioned offices. An empirical expression of an IEQ index associated with thermal comfort, indoor air quality, aural and visual comfort is used to benchmark the offices. Employing input parameters obtained from the building stocks of Hong Kong, the office portfolios regarding the thermal energy consumption and the IEQ index are determined by Monte Carlo simulations. In particular, an energy-to-acceptance ratio and an energy-to-IEQ improvement ratio are proposed to measure the performance of energy consumption for the IEQ in the air-conditioned offices. The ratios give the thermal energy consumption corresponding to a desirable percentage of IEQ acceptances and to an IEQ upgrade, respectively. The results showed a non-linear increasing trend of annual thermal energy consumption for IEQ improvement at the offices of higher IEQ benchmarks. The thermal energy consumption for visual comfort and indoor air quality would also be significant in these offices. This study provides useful information that incorporates the IEQ in air-conditioned offices into the development of performance evaluation measures for thermal energy consumption.

  12. Very low energy homes in the United States: Perspectives on performance from measured data

    Energy Technology Data Exchange (ETDEWEB)

    Parker, Danny S. [Florida Solar Energy Center, 1679 Clearlake Rd., Cocoa, FL 32922 (United States)

    2009-05-15

    We present measured annual performance data from a dozen recent-vintage very low energy homes in North America. Many of the designs combine greater energy efficiency with solar electric photovoltaic power in an attempt to create Zero Energy Homes (ZEH). We also provide measured data from the first home constructed to the German Passivhaus standard in the United States. Several projects either exceeded or come very close to true net zero energy when evaluated over a year. The data indicate that very low energy use buildings can very readily be achieved in North America. Annual energy use half that or less than standard housing can be achieved for an equivalent cost of $0.10/kWh from the efficiency investment. In general, the better cost effectiveness seen from energy efficiency measures indicates that greater investment in conservation should be a prerequisite to installation of solar water heating and solar electricity in Zero Energy Homes. However, over emphasis in efficiency is also possible. This suggests that optimization tools such as BEopt and EGUSA, which characterize both renewable resource performance and that also of specific combinations of energy efficiency measures, will best guide designers to locate the most economically favorable mix to reach an energy neutral level. (author)

  13. Development of a performance-based industrial energy efficiency indicator for corn refining plants.

    Energy Technology Data Exchange (ETDEWEB)

    Boyd, G. A.; Decision and Information Sciences; USEPA

    2006-07-31

    Organizations that implement strategic energy management programs have the potential to achieve sustained energy savings if the programs are carried out properly. A key opportunity for achieving energy savings that plant managers can take is to determine an appropriate level of energy performance by comparing their plant's performance with that of similar plants in the same industry. Manufacturing facilities can set energy efficiency targets by using performance-based indicators. The U.S. Environmental Protection Agency (EPA), through its ENERGY STAR{reg_sign} program, has been developing plant energy performance indicators (EPIs) to encourage a variety of U.S. industries to use energy more efficiently. This report describes work with the corn refining industry to provide a plant-level indicator of energy efficiency for facilities that produce a variety of products--including corn starch, corn oil, animal feed, corn sweeteners, and ethanol--for the paper, food, beverage, and other industries in the United States. Consideration is given to the role that performance-based indicators play in motivating change; the steps needed to develop indicators, including interacting with an industry to secure adequate data for an indicator; and the actual application and use of an indicator when complete. How indicators are employed in the EPA's efforts to encourage industries to voluntarily improve their use of energy is discussed as well. The report describes the data and statistical methods used to construct the EPI for corn refining plants. Individual equations are presented, as are the instructions for using them in an associated Excel spreadsheet.

  14. What encourages local authorities to engage with energy performance contracting for retrofitting? Evidence from German municipalities

    International Nuclear Information System (INIS)

    Polzin, Friedemann; Flotow, Paschen von; Nolden, Colin

    2016-01-01

    Municipalities aiming at mitigating climate change by implementing new energy efficiency technologies face budgetary and capacity constraints. Outsourcing through energy service contracting could provide a solution. This paper reports results from a survey of 1298 municipalities concerning barriers to retrofitting public street lighting and the possible role of energy service contracting to overcome these barriers. Using a logistic regression analysis, the authors investigate determinants of opting for energy service contracts in the specific context of LED retrofits. Results point to an advantage of outsourcing in a financially and capacity-constrained environment, which corresponds with the main reasons for engaging in contracting: minimising investments and financial risks. However, municipalities often do not fully grasp the risks associated with retrofitting especially using a novel technology such as LED. In relation to that they underestimate the risk reduction potential of energy performance contracts (EPC). Previous experience with outsourcing increases the probability to engage in servitization although certain existing partnerships, particularly with utilities, prevent municipalities from considering energy performance contracts. Interestingly, engaging an energy consultant has a negative propensity to use energy service contracts, while pre-negotiated standardised contracts for energy performance contracts have a positive influence. - Highlights: •Barriers to retrofitting can be addressed through energy performance contracts (EPC). •Outsourcing has the potential to alleviate personnel and financial constraints. •Standardised contracts and previous experience with outsourcing facilitate use of EPC. •Engaging energy consultants has a negative influence on the willingness to adopt EPC. •Policy makers could support facilitators and standard contracts to boost EPC market.

  15. Financing Solar Energy Systems with Energy Savings Performance Contracts in the Federal Sector: Results of a Survey on Barriers

    Energy Technology Data Exchange (ETDEWEB)

    Gee, R. C.; LaPorta, C.

    1999-08-17

    This report summarizes the findings of an investigation into financing solar energy systems for the Federal sector. The objectives of the investigation were (1) to identify the barriers that impede companies from using Energy Savings Performance Contracts (ESPCs) to develop solar energy projects for Federal facilities, and (2) to clarify the impacts of Federal contracting requirements on energy service companies' use of ESPCs. Twenty-four representatives of energy service companies agreed to be interviewed. Their responses indicate that these are the primary barriers to greater use of ESPCs: the relatively long payback periods for investments in solar technologies; the length of the ESPC process; the cost of certain contractual requirements regarding wages and financing; and a lack of knowledge about the actual cost and reliability of solar systems. The report proposes a number of actions the government could take to remove these barriers, including (1) streamlining and shortening the ESPC process and (2) doing more to inform both government agencies and energy service companies about the costs and benefits of solar systems.

  16. Increasing the energy performance of cement works; Des solutions pour ameliorer la performance energetique des cimenteries

    Energy Technology Data Exchange (ETDEWEB)

    Bolliger, M.; Gallestey, E.; Crosiey, G.; Kiener, M.

    2009-07-01

    Cement works are consuming much thermal and electric energy and this affects the production cost. In the past years, much effort has been put on how to reduce this consumption and cost. Alternative fuels and raw materials have been introduced. As a result the optimization of the production process has become more sophisticated. This article describes a series of computerized tools developed by the company ABB Ltd., which were designed to improve quality assurance and productivity. They apply to the whole production process, including the rotary kiln, the pollutants' emissions in exhaust gases, the numerous ventilators and the crushers. Variable speed drives for ventilators and temperature control in the kiln are amongst the key factors. The optimizers also consider the different cement qualities to be produced in successive batches and the time-dependent electricity prices.

  17. Assessing measures of energy efficiency performance and their application in industry

    Energy Technology Data Exchange (ETDEWEB)

    Tanaka, K.

    2008-02-15

    This paper explores different measures of energy efficiency performance (hereafter referred to as 'MEEP'): absolute energy consumption, energy intensity, diffusion of specific energy-saving technology and thermal efficiency. It discusses their advantages and disadvantages and their roles within policy frameworks. MEEP may be necessary at several stages during policy design: in a developing regulatory framework; during the actual application; and in evaluation after policy implementation. Policy makers should consider the suitability of MEEP at each of these stages, based on criteria such as reliability, feasibility and verifiability. The paper considers the importance of so-called boundary definitions when measuring energy performance, and how these affect the appropriateness of country comparisons to guide policy decisions. The paper also addresses the limitations of both energy intensity and technology diffusion indicators as measures of energy efficiency performance. A case study on Japan's iron and steel industry illustrates the critical role of proper boundary definitions for a meaningful assessment of energy efficiency in industry. Depending on the boundaries set for the analysis, the energy consumption per ton of crude steel ranges from 16 to 21 GJ. Both a proper understanding of various methods to assess energy efficiency and the linkage with policy objectives and frameworks are important. Using the diffusion rates of specific energy-efficient processes is a technology-oriented approach which seeks to encourage the retrofitting or replacement of less efficient equipment. There are fewer boundary problems using diffusion rates than by calculating energy consumption. 42 refs., 15 figs., 4 tabs., 1 app.

  18. Enactment of mandatory pharmacy technician certification in Kansas.

    Science.gov (United States)

    Lucas, Amber; Massey, Lindsay; Gill, Taylor; Burger, Gregory; Little, Jeff D

    2016-02-01

    The successful enactment of mandatory pharmacy technician certification in Kansas is described. In 2004, Kansas began requiring registration of all pharmacy technicians with the state board of pharmacy. Registration identified individuals working as pharmacy technicians but did not require any specific education or certification. In September 2012, the Kansas Board of Pharmacy created a task force of key stakeholders including pharmacists from multiple areas of practice, the University of Kansas School of Pharmacy, organizational leaders from the Kansas Council of Health-System Pharmacists (KCHP) and Kansas Pharmacists Association, and professional lobbyists. The goals of this task force were to research practices of technician certification in other states and to make recommendations to the state board of pharmacy on how Kansas could accomplish mandatory technician certification. The task force outlined the steps needed to achieve legislation that could be supported by the members. These topics included the creation of a technician trainee category, grandfathering certain technicians who had been practicing for a designated period of time, state board-approved exemptions, training requirements, age and education requirements, continuing-education requirements, and pharmacist:technician ratio. The recommendations were finalized at the August 2013 Kansas Pharmacy Summit, and the proposed legislation was introduced and passed during the 2014 legislative session. KCHP members learned many valuable lessons about advocacy and the legislative process with this initiative, including building relationships, working with legislators, and working with other professional organizations. The formation of a task force led to the successful passage of a bill granting the Kansas Board of Pharmacy the authority to issue regulations regarding mandatory pharmacy technician certification. Copyright © 2016 by the American Society of Health-System Pharmacists, Inc. All rights reserved.

  19. A Model for Sustainable Building Energy Efficiency Retrofit (BEER) Using Energy Performance Contracting (EPC) Mechanism for Hotel Buildings in China

    Science.gov (United States)

    Xu, Pengpeng

    Hotel building is one of the high-energy-consuming building types, and retrofitting hotel buildings is an untapped solution to help cut carbon emissions contributing towards sustainable development. Energy Performance Contracting (EPC) has been promulgated as a market mechanism for the delivery of energy efficiency projects. EPC mechanism has been introduced into China relatively recently, and it has not been implemented successfully in building energy efficiency retrofit projects. The aim of this research is to develop a model for achieving the sustainability of Building Energy Efficiency Retrofit (BEER) in hotel buildings under the Energy Performance Contracting (EPC) mechanism. The objectives include: • To identify a set of Key Performance Indicators (KPIs) for measuring the sustainability of BEER in hotel buildings; • To identify Critical Success Factors (CSFs) under EPC mechanism that have a strong correlation with sustainable BEER project; • To develop a model explaining the relationships between the CSFs and the sustainability performance of BEER in hotel building. Literature reviews revealed the essence of sustainable BEER and EPC, which help to develop a conceptual framework for analyzing sustainable BEER under EPC mechanism in hotel buildings. 11 potential KPIs for sustainable BEER and 28 success factors of EPC were selected based on the developed framework. A questionnaire survey was conducted to ascertain the importance of selected performance indicators and success factors. Fuzzy set theory was adopted in identifying the KPIs. Six KPIs were identified from the 11 selected performance indicators. Through a questionnaire survey, out of the 28 success factors, 21 Critical Success Factors (CSFs) were also indentified. Using the factor analysis technique, the 21 identified CSFs in this study were grouped into six clusters to help explain project success of sustainable BEER. Finally, AHP/ANP approach was used in this research to develop a model to

  20. There Is More to Transparency than Meets the Eye: The Impact of Mandatory Disclosure Laws Aimed at Promoting Breastfeeding.

    Science.gov (United States)

    Lytton, Timothy D; Dennison, Barbara A; Nguyen, Trang Q; Jurkowski, Janine M

    2014-01-01

    Requiring hospitals to inform patients of clinical best practices and to disclose performance data are two common regulatory strategies for improving healthcare. Proponents of such mandatory disclosure laws--sometimes referred to as "targeted transparency "--argue that they increase patient awareness and thereby create reputational incentives for hospitals to improve their performance. Evaluation of targeted transparency typically focuses on patient responses to information and changes in hospital behavior based on reputational concerns. This standard account, however, overlooks other important ways targeted transparency can influence hospital performance. This article presents a case study of disclosure laws designed to promote breastfeeding to illustrate how targeted transparency can influence hospitals independently of its effects on patients' choice of provider or hospitals' fear of losing business. We found that mandatory disclosure laws emboldened state regulators to take a more aggressive approach to enforcement of hospital regulations, empowered nurse managers to advocate more effectively within hospitals for changes in hospital policies, and enabled nurse managers to implement verifiable performance goals for clinical staff under their supervision. These findings suggest that the study of mandatory disclosure more generally--in areas such as financial regulation, environmental protection, food labeling, and workplace safety--would benefit by analyzing not only its influence on public awareness and its reputational effects but also how regulators use transparency laws and how managers within regulated entities employ the information that the laws provide.

  1. Energy Design Guidelines for High Performance Schools: Hot and Humid Climates

    Energy Technology Data Exchange (ETDEWEB)

    2002-06-01

    School districts around the country are finding that the smart energy choices can help them save money and provide healthier, more effective learning environments. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs. These savings can be redirected to educational needs such as additional teachers, instructional materials, or new computers. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school. By incorporating these principles, you can create and exemplary building that is both energy and resource efficient.

  2. Energy Design Guidelines for High Performance Schools: Temperate and Humid Climates

    Energy Technology Data Exchange (ETDEWEB)

    2002-06-01

    School districts around the country are finding that the smart energy choices can help them save money and provide healthier, more effective learning environments. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs. These savings can be redirected to educational needs such as additional teachers, instructional materials, or new computers. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school. By incorporating these principles, you can create and exemplary building that is both energy and resource efficient.

  3. Energy Design Guidelines for High Performance Schools: Temperate and Mixed Climates

    Energy Technology Data Exchange (ETDEWEB)

    2002-06-01

    School districts around the country are finding that the smart energy choices can help them save money and provide healthier, more effective learning environments. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs. These savings can be redirected to educational needs such as additional teachers, instructional materials, or new computers. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school. By incorporating these principles, you can create and exemplary building that is both energy and resource efficient.

  4. Energy Design Guidelines for High Performance Schools: Cold and Humid Climates

    Energy Technology Data Exchange (ETDEWEB)

    2002-06-01

    School districts around the country are finding that the smart energy choices can help them save money and provide healthier, more effective learning environments. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs. These savings can be redirected to educational needs such as additional teachers, instructional materials, or new computers. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school. By incorporating these principles, you can create and exemplary building that is both energy and resource efficient.

  5. Energy Design Guidelines for High Performance Schools: Cool and Dry Climates

    Energy Technology Data Exchange (ETDEWEB)

    2002-06-01

    School districts around the country are finding that the smart energy choices can help them save money and provide healthier, more effective learning environments. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs. These savings can be redirected to educational needs such as additional teachers, instructional materials, or new computers. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school. By incorporating these principles, you can create and exemplary building that is both energy and resource efficient.

  6. Energy Design Guidelines for High Performance Schools: Hot and Dry Climates

    Energy Technology Data Exchange (ETDEWEB)

    2002-01-01

    School districts around the country are finding that smart energy choices can help them save money and provide healthier, more effective learning environments. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs. These savings can be redirected to educational needs such as additional teachers, instructional materials, or new computers. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school. By incorporating these principles, you can create an exemplary building that is both energy and resource efficient.

  7. Energy Design Guidelines for High Performance Schools: Cool and Humid Climates

    Energy Technology Data Exchange (ETDEWEB)

    2002-06-01

    School districts around the country are finding that the smart energy choices can help them save money and provide healthier, more effective learning environments. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs. These savings can be redirected to educational needs such as additional teachers, instructional materials, or new computers. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school. By incorporating these principles, you can create and exemplary building that is both energy and resource efficient.

  8. Energy Design Guidelines for High Performance Schools: Hot and Dry Climates (Revision)

    Energy Technology Data Exchange (ETDEWEB)

    2002-06-01

    School districts around the country are finding that the smart energy choices can help them save money and provide healthier, more effective learning environments. By incorporating energy improvements into their construction or renovation plans, schools can significantly reduce energy consumption and costs. These savings can be redirected to educational needs such as additional teachers, instructional materials, or new computers. These design guidelines outline high performance principles for the new or retrofit design of your K-12 school. By incorporating these principles, you can create and exemplary building that is both energy and resource efficient.

  9. Avoiding mandatory hospital nurse staffing ratios: an economic commentary.

    Science.gov (United States)

    Buerhaus, Peter I

    2009-01-01

    The imposition of mandatory hospital nurse staffing ratios is among the more visible public policy initiatives affecting the nursing profession. Although the practice is intended to address problems in hospital nurse staffing and quality of patient care, this commentary argues that staffing ratios will lead to negative consequences for nurses involving the equity, efficiency, and costs of producing nursing care in hospitals. Rather than spend time and effort attempting to regulate nurse staffing, this commentary offers alternatives strategies that are directed at fixing the problems that motivate the advocates of staffing ratios.

  10. [The effect of energy drinks on the cognitive performance of adolescents].

    Science.gov (United States)

    Wilhelm, P; van Diepen, M A C; Nieuwenhuis, L; Boulogne, T L A

    2013-01-01

    Manufacturers of energy drinks claim that their drinks can have a positive effect on cognitive performance. So far, there is little evidence that energy drinks do in fact enhance the cognitive performance of adolescents. To find out, via a series of tests, whether the manufacturers of energy drinks are justified in claiming that their drinks improve the cognitive performance of young people. In a quasi-experimental design a number of young people (aged 15-18) were divided into three groups: a control group, each of whose members drank water beforehand; a placebo group whose members drank a glass of sugar-free lemonade, and an experimental group whose members drank a currently available energy drink (Megaforce). Pencil and paper tests were administered to the members of each group in order to measure attention and concentration, learning ability, memory, verbal and numerical reasoning, numerical aptitude and vocabulary. No significant differences between groups were found that could solely be ascribed to the effect of energy drink. Given the warnings about the potential health-risks of energy drinks and the fact that no evidence was found for positive effects of energy drinks on the cognitive performance of young people, we are of the opinion that youngsters should stay away from such drinks.

  11. Numerical and experimental assessment of thermal performance of vertical energy piles: An application

    International Nuclear Information System (INIS)

    Gao Jun; Zhang Xu; Liu Jun; Li Kuishan; Yang Jie

    2008-01-01

    A district space heating and cooling system using geothermal energy from bearing piles was designed in Shanghai and will be installed in two years before 2010. This paper describes the pile-foundation heat exchangers applied in an energy pile system for an actual architectural complex in Shanghai, 30% of whose cooling/heating load was designed to be provided by a ground-source heat pump (GSHP) system using the energy piles. In situ performance tests of heat transfer are carried out to figure out the most efficient type of energy pile and to specify the design of energy pile system. Numerical investigation is also performed to confirm the test results and to demonstrate the medium temperature variations along the pipes. The averaged heat resistance and heat injection rate of different types of energy piles are calculated from the test and numerical results. The effect of pile type, medium flow rate and inlet temperature on thermal performance is separately discussed. From the viewpoint of energy efficiency and adjustability, the W-shaped underground heat exchanger with moderate medium flow rate is finally adopted for the energy pile system

  12. Performance analysis of solar energy integrated with natural-gas-to-methanol process

    International Nuclear Information System (INIS)

    Yang, Sheng; Liu, Zhiqiang; Tang, Zhiyong; Wang, Yifan; Chen, Qianqian; Sun, Yuhan

    2017-01-01

    Highlights: • Solar energy integrated with natural-gas-to-methanol process is proposed. • The two processes are modeled and simulated. • Performance analysis of the two processes are conducted. • The proposed process can cut down the greenhouse gas emission. • The proposed process can save natural gas consumption. - Abstract: Methanol is an important platform chemical. Methanol production using natural gas as raw material has short processing route and well developed equipment and technology. However, natural gas reserves are not large in China. Solar energy power generation system integrated with natural-gas-to-methanol (NGTM) process is developed, which may provide a technical routine for methanol production in the future. The solar energy power generation produces electricity for reforming unit and system consumption in solar energy integrated natural-gas-to-methanol system (SGTM). Performance analysis of conventional natural-gas-to-methanol process and solar energy integrated with natural-gas-to-methanol process are presented based on simulation results. Performance analysis was conducted considering carbon efficiency, production cost, solar energy price, natural gas price, and carbon tax. Results indicate that solar energy integrated with natural-gas-to-methanol process is able to cut down the greenhouse gas (GHG) emission. In addition, solar energy can replace natural gas as fuel. This can reduce the consumption of natural gas, which equals to 9.2% of the total consumed natural gas. However, it is not economical considering the current technology readiness level, compared with conventional natural-gas-to-methanol process.

  13. Improving the performance of a hybrid electric vehicle by utilization regenerative braking energy of vehicle

    Energy Technology Data Exchange (ETDEWEB)

    Mourad, Mohamed [Automotive and Tractors Department, Faculty of Engineering, Minia University (Egypt)

    2011-07-01

    Environmentally friendly vehicles with range and performance capabilities surpassing those of conventional ones require a careful balance among competing goals for fuel efficiency, performance and emissions. It can be recuperated the energy of deceleration case of the vehicle to reuse it to recharge the storage energy of hybrid electric vehicle and increase the state of charge of batteries under the new conditions of vehicle operating in braking phase. Hybrid electric vehicle has energy storage which allows decreasing required peak value of power from prime mover, which is the internal combustion engine. The paper investigates the relationships between the driving cycle phases and the recuperation energy to the batteries system of hybrid electric vehicle. This work describes also a methodology for integrating this type of hybrid electric vehicle in a simulation program. A design optimization framework is then used to find the best position that we can utilize the recuperation energy to recharge the storage batteries of hybrid electric vehicle.

  14. Hypersonic wave drag reduction performance of cylinders with repetitive laser energy depositions

    International Nuclear Information System (INIS)

    Fang, J; Hong, Y J; Li, Q; Huang, H

    2011-01-01

    It has been widely research that wave drag reduction on hypersonic vehicle by laser energy depositions. Using laser energy to reduce wave drag can improve vehicle performance. A second order accurate scheme based on finite-difference method and domain decomposition of structural grid is used to compute the drag performance of cylinders in a hypersonic flow of Mach number 2 at altitude of 15km with repetitive energy depositions. The effects of frequency on drag reduction are studied. The calculated results show: the recirculation zone is generated due to the interaction between bow shock over the cylinder and blast wave produced by energy deposition, and a virtual spike which is supported by an axis-symmetric recirculation, is formed in front of the cylinder. By increasing the repetitive frequency, the drag is reduced and the oscillation of the drag is decreased; however, the energy efficiency decreases by increasing the frequency.

  15. Influence of high energy β-radiation on thermoelectric performance of filled skutterudites compounds

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Jikun, E-mail: jikunchen@seas.harvard.edu [CAS Key Laboratory of Materials for Energy Conversion, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); Zha, Hao [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle & Radiation Imaging, Tsinghua University, Ministry of Education, Beijing (China); Xia, Xugui; Qiu, Pengfei; Li, Yulong [CAS Key Laboratory of Materials for Energy Conversion, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); Wang, Chuanjing; Han, Yunsheng [Nuctech Company Limited, Beijing (China); Shi, Xun; Chen, Lidong [CAS Key Laboratory of Materials for Energy Conversion, Shanghai Institute of Ceramics, Chinese Academy of Sciences, Shanghai 200050 (China); Jin, Qingxiu [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle & Radiation Imaging, Tsinghua University, Ministry of Education, Beijing (China); Chen, Huaibi, E-mail: chenhb@mail.tsinghua.edu.cn [Department of Engineering Physics, Tsinghua University, Beijing 100084 (China); Key Laboratory of Particle & Radiation Imaging, Tsinghua University, Ministry of Education, Beijing (China)

    2015-08-15

    Highlights: • Impact by MeV β-rays irradiation on skutterudite TE material was investigated. • Monte-Carlo simulation is used to simulate the deposited energy irradiations. • The high deposited energy does not change the TE performance. • The light irradiation does not show a significant impact on TE materials. - Abstract: The influence of MeV β-rays irradiation on the thermoelectric performance of n-type filled skutterudite material has been investigated using an electron accelerator. Using a Monte-Carlo simulation base on Fluka code, the deposited energy in the sample material from the irradiation is estimated, which shows a large power deposited around 50 W/mm. Nevertheless, the thermoelectric performances of the filled skutterudite samples are compared before and after irradiations. It indicates that the thermoelectric material will not be easily jeopardized by ‘light’ irradiations with energy lower than MeV range.

  16. Influence of high energy β-radiation on thermoelectric performance of filled skutterudites compounds

    International Nuclear Information System (INIS)

    Chen, Jikun; Zha, Hao; Xia, Xugui; Qiu, Pengfei; Li, Yulong; Wang, Chuanjing; Han, Yunsheng; Shi, Xun; Chen, Lidong; Jin, Qingxiu; Chen, Huaibi

    2015-01-01

    Highlights: • Impact by MeV β-rays irradiation on skutterudite TE material was investigated. • Monte-Carlo simulation is used to simulate the deposited energy irradiations. • The high deposited energy does not change the TE performance. • The light irradiation does not show a significant impact on TE materials. - Abstract: The influence of MeV β-rays irradiation on the thermoelectric performance of n-type filled skutterudite material has been investigated using an electron accelerator. Using a Monte-Carlo simulation base on Fluka code, the deposited energy in the sample material from the irradiation is estimated, which shows a large power deposited around 50 W/mm. Nevertheless, the thermoelectric performances of the filled skutterudite samples are compared before and after irradiations. It indicates that the thermoelectric material will not be easily jeopardized by ‘light’ irradiations with energy lower than MeV range

  17. Simulating the dust effect on the energy performance of photovoltaic generators based on experimental measurements

    International Nuclear Information System (INIS)

    Kaldellis, J.K.; Kapsali, M.

    2011-01-01

    One of the least analyzed side effects of atmospheric air pollution is the degradation of PV-panels' performance due to the deposition of solid particles varying in composition, size and type. In the current study, the experimental data concerning the effect of three representative air pollutants (i.e. red soil, limestone and carbonaceous fly-ash particles) on the energy performance of PV installations are analyzed. According to the results obtained, a considerable reduction of PVs' energy performance is recorded, depending strongly on particles' composition and source. Subsequently, a theoretical model has been developed in order to be used as an analytical tool for obtaining reliable results concerning the expected effect of regional air pollution on PVs' performance. Furthermore, experimental results concerning the dust effect on PVs' energy yield in an aggravated - from air pollution - urban environment are used to validate the proposed theoretical model. -- Highlights: → The effect of dust deposition on PVs energy efficiency is experimentally examined. → Based on the results, a considerable reduction of PVs energy performance is recorded. → The effect strongly depends on the dust composition and on the type of the pollutant. → A theoretical model is developed for predicting the dust deposition effect on PVs energy yield. → The model is validated on the basis of experiments conducted in urban environment.

  18. The Impact of Insulation and HVAC Degradation on Overall Building Energy Performance: A Case Study

    Directory of Open Access Journals (Sweden)

    Georgios Eleftheriadis

    2018-02-01

    Full Text Available Through monitoring of buildings, it can be proven that the performance of envelope elements and energy supply systems deteriorates with time. The results of this degradation are higher energy consumption and life cycle costs than projected in the building design phase. This paper considers the impacts of this deterioration on the whole building energy performance with the goal of improving the accuracy of long term performance calculations. To achieve that, simplified degradation equations found in literature are applied on selected envelope elements and heating system components of a single-family house in Germany. The energy performance of the building over 20 years is determined through simulations by EnergyPlus and MATLAB. The simulation results show that, depending on maintenance and primary heating system, the building can consume between 18.4% and 47.1% more primary energy over 20 years compared to a scenario in which no degradation were to occur. Thus, it can be concluded that considering performance drop with time is key in order to improve the decision-making process when designing future-proof buildings.

  19. Thermal mass impact on energy performance of a low, medium and heavy mass building in Belgrade

    Directory of Open Access Journals (Sweden)

    Anđelković Bojan V.

    2012-01-01

    Full Text Available Heavy mass materials used in building structures and architecture can significantly affect building energy performance and occupant comfort. The purpose of this study was to investigate if thermal mass can improve the internal environment of a building, resulting in lower energy requirements from the mechanical systems. The study was focused on passive building energy performance and compared annual space heating and cooling energy requirements for an office building in Belgrade with several different applications of thermal mass. A three-dimensional building model was generated to represent a typical office building. Building shape, orientation, glazing to wall ratio, envelope insulation thickness, and indoor design conditions were held constant while location and thickness of building mass (concrete was varied between cases in a series of energy simulations. The results were compared and discussed in terms of the building space heating and cooling energy and demand affected by thermal mass. The simulation results indicated that with addition of thermal mass to the building envelope and structure: 100% of all simulated cases experienced reduced annual space heating energy requirements, 67% of all simulated cases experienced reduced annual space cooling energy requirements, 83% of all simulated cases experienced reduced peak space heating demand and 50% of all simulated cases experienced reduced peak space cooling demand. The study demonstrated that there exists a potential for reducing space heating and cooling energy requirements with heavy mass construction in the analyzed climate region (Belgrade, Serbia.

  20. Cost-optimal energy performance renovation measures of educational buildings in cold climate

    International Nuclear Information System (INIS)

    Niemelä, Tuomo; Kosonen, Risto; Jokisalo, Juha

    2016-01-01

    Highlights: • The proposed national nZEB target can be cost-effectively achieved in renovations. • Energy saving potential of HVAC systems is significant compared to the building envelope. • Modern renewable energy production technologies are cost-efficient and recommendable. • Improving the indoor climate conditions in deep renovations is recommendable. • Simulation-based optimization method is efficient in building performance analyzes. - Abstract: The paper discusses cost-efficient energy performance renovation measures for typical educational buildings built in the 1960s and 1970s in cold climate regions. The study analyzes the impact of different energy renovation measures on the energy efficiency and economic viability in a Finnish case study educational building located in Lappeenranta University of Technology (LUT) campus area. The main objective of the study was to determine the cost-optimal energy performance renovation measures to meet the proposed national nearly zero-energy building (nZEB) requirements, which are defined according to the primary energy consumption of buildings. The main research method of the study was simulation-based optimization (SBO) analysis, which was used to determine the cost-optimal renovation solutions. The results of the study indicate that the minimum national energy performance requirement of new educational buildings (E_p_r_i_m_a_r_y ⩽ 170 kWh/(m"2,a)) can be cost-effectively achieved in deep renovations of educational buildings. In addition, the proposed national nZEB-targets are also well achievable, while improving the indoor climate (thermal comfort and indoor air quality) conditions significantly at the same time. Cost-effective solutions included renovation of the original ventilation system, a ground source heat pump system with relatively small dimensioning power output, new energy efficient windows and a relatively large area of PV-panels for solar-based electricity production. The results and

  1. The operational performance of “net zero energy building”: A study in China

    International Nuclear Information System (INIS)

    Zhou, Zhihua; Feng, Lei; Zhang, Shuzhen; Wang, Chendong; Chen, Guanyi; Du, Tao; Li, Yasong; Zuo, Jian

    2016-01-01

    Highlights: • Choose energy efficiency technology in office building to implement “nZEB”. • Simulate its energy consumption. • Study on the operational performance. • Optimize its running. - Abstract: There is no lack of studies on “net zero energy buildings” (“nZEB”). However, the vast majority of these studies focus on theories and simulation. The actual operational performance of “net zero energy building” during occupation has been largely overlooked by previous studies. This study aims to investigate the operational performance of net “zero energy buildings” via the case study of an office building in Tianjin, China. Using simulation, the energy consumption of the building at design phase was estimated and a solar photovoltaic (PV) system was selected. A whole year operation of the occupied building showed that energy consumption of the case building was much higher than the energy generated from the solar PV system. This was mainly due to three issues. Firstly, the equipment was different in terms of category, quantity and running time between operation and design stages, leading to considerable underestimate of energy consumption at the design stage. Secondly, the operational strategies need to be further improved in order to regulate users’ behaviors. Thirdly, the efficiency of solar PV system was substantially reduced due to poor atmospheric environment (i.e. haze weather). Therefore, during the design process of “net zero energy buildings”, it is imperative to ensure that the energy simulation accurately reflects how the building will actually operate once occupied. The research also revealed other barriers to the design and implementation of “nZEB” in China, such as extra efforts required for effective communicating the capacity of the HVAC design and systems to clients, and the increased cost of “nZEB” (e.g. solar PV system) particularly for public buildings. Finally, the solar radiation intensity of standard

  2. Achieving informed decision-making for net zero energy buildings design using building performance simulation tools

    NARCIS (Netherlands)

    Attia, S.G.; Gratia, E.; De Herde, A.; Hensen, J.L.M.

    2013-01-01

    Building performance simulation (BPS) is the basis for informed decision-making of Net Zero Energy Buildings (NZEBs) design. This paper aims to investigate the use of building performance simulation tools as a method of informing the design decision of NZEBs. The aim of this study is to evaluate the

  3. Energy Efficiency in Ethernet Passive Optical Networks (EPONs): Protocol Design and Performance Evaluation

    DEFF Research Database (Denmark)

    Yan, Ying; Dittmann, Lars

    2011-01-01

    a suitable wakeup time scheduler at the Optical Line Terminal (OLT). A generic EPON system is considered, which is composed of an OLT and several ONUs that are EMM enabled. An energy consumption optimization problem aimed at saving energy is proposed and two heuristic sleep mode scheduling policies......As concerns about energy consumption grow, the power consumption of the EPON becomes a matter of increasing importance. In respect of energy efficiency, the current standard has no management protocols aiming to reduce power consumption in EPONs. In this paper, we propose an Energy Management...... and guaranteeing the network performance at the same time. Simulation results show that an EMM-based EPON with well designed scheduling disciplines is essential to achieving significant energy saving while meeting the delay constraint....

  4. Energy and water uses and their performance explanatory indicators in hotels in Hong Kong

    International Nuclear Information System (INIS)

    Deng, S.

    2003-01-01

    This paper firstly presents a case study on analyzing the electrical load profiles recorded in a Hong Kong hotel over a period of 12 months to examine the potential energy saving opportunities (ESOs) in its building services installations. The case study is followed by a report of the survey results of energy and water use in 36 quality hotels in Hong Kong. Finally, a regression analysis where the surveyed energy and water use data were correlated to a number of hotel background or operational parameters to search for suitable energy and water use performance explanatory indicators is presented. The survey results depict a diversified energy and water use situation in Hong Kong's hotels, but the regression analysis indicates that, while some of the correlations obtained are weak, there do exist a few strong energy and water explanatory indicators. (author)

  5. Real estate market and building energy performance: Data for a mass appraisal approach.

    Science.gov (United States)

    Bonifaci, Pietro; Copiello, Sergio

    2015-12-01

    Mass appraisal is widely considered an advanced frontier in the real estate valuation field. Performing mass appraisal entails the need to get access to base information conveyed by a large amount of transactions, such as prices and property features. Due to the lack of transparency of many Italian real estate market segments, our survey has been addressed to gather data from residential property advertisements. The dataset specifically focuses on property offer prices and dwelling energy efficiency. The latter refers to the label expressed and exhibited by the energy performance certificate. Moreover, data are georeferenced with the highest possible accuracy: at the neighborhood level for a 76.8% of cases, at street or building number level for the remaining 23.2%. Data are related to the analysis performed in Bonifaci and Copiello [1], about the relationship between house prices and building energy performance, that is to say, the willingness to pay in order to benefit from more efficient dwellings.

  6. Paying for Forest Ecosystem Services: Voluntary Versus Mandatory Payments

    Science.gov (United States)

    Roesch-McNally, Gabrielle E.; Rabotyagov, Sergey S.

    2016-03-01

    The emergence of new markets for forest ecosystem services can be a compelling opportunity for market diversification for private forest landowners, while increasing the provision of public goods from private lands. However, there is limited information available on the willingness-to-pay (WTP) for specific forest ecosystem services, particularly across different ecosystem market mechanisms. We utilize survey data from Oregon and Washington households to compare marginal WTP for forest ecosystem services and the total WTP for cost-effective bundles of forest ecosystem services obtained from a typical Pacific Northwest forest across two value elicitation formats representing two different ecosystem market mechanisms: an incentive-compatible choice experiment involving mandatory tax payments and a hypothetical private provision scenario modeled as eliciting contributions to the preferred forest management alternative via a provision point mechanism with a refund. A representative household's total WTP for the average forest management program was estimated at 217.59 per household/year under a mandatory tax mechanism and 160.44 per household/per year under a voluntary, crowdfunding-style, contribution mechanism; however, these estimates are not statistically different. Marginal WTP estimates were assessed for particular forest ecosystem service attributes including water quality, carbon storage, mature forest habitat, and public recreational access. This study finds that survey respondents place significant economic value on forest ecosystem services in both elicitation formats and that the distributions of the marginal WTP are not statistically significantly different.

  7. Paying for Forest Ecosystem Services: Voluntary Versus Mandatory Payments.

    Science.gov (United States)

    Roesch-McNally, Gabrielle E; Rabotyagov, Sergey S

    2016-03-01

    The emergence of new markets for forest ecosystem services can be a compelling opportunity for market diversification for private forest landowners, while increasing the provision of public goods from private lands. However, there is limited information available on the willingness-to-pay (WTP) for specific forest ecosystem services, particularly across different ecosystem market mechanisms. We utilize survey data from Oregon and Washington households to compare marginal WTP for forest ecosystem services and the total WTP for cost-effective bundles of forest ecosystem services obtained from a typical Pacific Northwest forest across two value elicitation formats representing two different ecosystem market mechanisms: an incentive-compatible choice experiment involving mandatory tax payments and a hypothetical private provision scenario modeled as eliciting contributions to the preferred forest management alternative via a provision point mechanism with a refund. A representative household's total WTP for the average forest management program was estimated at $217.59 per household/year under a mandatory tax mechanism and $160.44 per household/per year under a voluntary, crowdfunding-style, contribution mechanism; however, these estimates are not statistically different. Marginal WTP estimates were assessed for particular forest ecosystem service attributes including water quality, carbon storage, mature forest habitat, and public recreational access. This study finds that survey respondents place significant economic value on forest ecosystem services in both elicitation formats and that the distributions of the marginal WTP are not statistically significantly different.

  8. From volatility to value: analysing and managing financial and performance risk in energy savings projects

    International Nuclear Information System (INIS)

    Mills, Evan; Kromer, Steve; Weiss, Gary; Mathew, Paul A.

    2006-01-01

    Many energy-related investments are made without a clear financial understanding of their values, risks, and volatilities. In the face of this uncertainty, the investor-such as a building owner or an energy service company-will often choose to implement only the most certain and thus limited energy-efficiency measures. Conversely, commodities traders and other sophisticated investors accustomed to evaluating investments on a value, risk, and volatility basis often overlook energy-efficiency investments because risk and volatility information are not provided. Fortunately, energy-efficiency investments easily lend themselves to such analysis using tools similar to those applied to supply side risk management. Accurate and robust analysis demands a high level of understanding of the physical aspects of energy-efficiency, which enables the translation of physical performance data into the language of investment. With a risk management analysis framework in place, the two groups-energy-efficiency experts and investment decision-makers-can exchange the information they need to expand investment in demand-side energy projects. In this article, we first present the case for financial risk analysis in energy efficiency in the buildings sector. We then describe techniques and examples of how to identify, quantify, and manage risk. Finally, we describe emerging market-based opportunities in risk management for energy efficiency

  9. Mandatory International Financial Reporting Standards Adoption and Cost of Equity Capital in Nigeria

    Directory of Open Access Journals (Sweden)

    Uwuigbe Uwalomwa

    2016-05-01

    Full Text Available This study examined the effect of mandatory International Financial Reporting Standards (IFRS adoption on the cost of equity capital on Nigerian firms and whether the cost of equity capital effect after adoption of IFRS can be moderated by Return on Equity. The study covered a sample of 11 listed companies in the industrial goods sector for the period 2011 and 2013. The data for the study was secondary data generated from the annual reports and stock market report websites. The cost of equity capital was shown as the expected return on the basic value of a share and computed based on pre and post-adoption data. Findings from the study revealed that there is a significant positive relationship between the cost of equity capital and IFRS adoption indicating that the cost of equity capital increased. The market-based performance measure failed to have significant effect on the cost of equity capital after mandatory adoption. The study recommends that policies that improve domestic savings, as a principal source of equity capital, be enacted as an increase should lead to a reduction in the cost of equity capital, interest rates and increase the appeal of equity and foreign investments.

  10. Testing of Technology Acceptance Model on Core Banking System: A Perspective on Mandatory Use

    Directory of Open Access Journals (Sweden)

    Burhan Suryo Ambodo

    2017-03-01

    Full Text Available This study aims to examine the acceptance of Core Banking System (CBS which is mandatory use software. The objects of this research are teller, customer service, and back office Branch of Bank BPD DIY Wonosari. Data were measured using Likert scale in five range value. A number of 49 data were analyzed using Partial Least Square (PLS. The results showed that ease of use had no positive effect on symbolic adoption; attitudes toward usage and perceived conformance has a positive effect on symbolic adoption, ease of use and perceived compatibility has no effect on attitudes towards usage. Usability, satisfaction and compatibility that are felt to positively affect attitude toward usage. In the information technology model that is mandatory use, it is important to note the symbolic adoption of information technology therefore the performance of the user (employee/employee can remain good. In particular for banking institutions that using CBS, it is important to improve the use of CBS, user satisfaction and CBS conformity with business processes, given the current banking business processes that are constantly expanding, there is no possibility of adjusting CBS to business processes at later.

  11. Software and DVFS Tuning for Performance and Energy-Efficiency on Intel KNL Processors

    Directory of Open Access Journals (Sweden)

    Enrico Calore

    2018-06-01

    Full Text Available Energy consumption of processors and memories is quickly becoming a limiting factor in the deployment of large computing systems. For this reason, it is important to understand the energy performance of these processors and to study strategies allowing their use in the most efficient way. In this work, we focus on the computing and energy performance of the Knights Landing Xeon Phi, the latest Intel many-core architecture processor for HPC applications. We consider the 64-core Xeon Phi 7230 and profile its performance and energy efficiency using both its on-chip MCDRAM and the off-chip DDR4 memory as the main storage for application data. As a benchmark application, we use a lattice Boltzmann code heavily optimized for this architecture and implemented using several different arrangements of the application data in memory (data-layouts, in short. We also assess the dependence of energy consumption on data-layouts, memory configurations (DDR4 or MCDRAM and the number of threads per core. We finally consider possible trade-offs between computing performance and energy efficiency, tuning the clock frequency of the processor using the Dynamic Voltage and Frequency Scaling (DVFS technique.

  12. Analysis of energy saving performance for household refrigerator with thermal storage of condenser and evaporator

    International Nuclear Information System (INIS)

    Cheng, Wen-long; Ding, Miao; Yuan, Xu-dong; Han, Bing-Chuan

    2017-01-01

    Highlights: • A novel refrigerator with both HSC and CSE is proposed. • The operational characteristics of novel refrigerator is analyzed. • The comparison of CSE, HSC and DES refrigerators is analyzed. • DES refrigerator has a largest off-time to on-time ratio of 4.3. • DES refrigerator has the best electrical energy saving performance (32%). - Abstract: The heat transfer performances of evaporators and condensers significantly affect the efficiency of household refrigerators. For enhancing heat transfer of the condensers and evaporators, a novel dual energy storage (DES) refrigerator with both heat storage condenser (HSC) and cold storage evaporator (CSE) is proposed. The performance comparison of three kinds of energy storage refrigerators: HSC refrigerator, CSE refrigerator and DES refrigerator is analyzed by establishing dynamic simulation models. According to the simulation results, the DES refrigerator combines the advantage of HSC refrigerator and CSE refrigerator, it has more balanced operational cycle and higher evaporation pressure and temperature. The DES refrigerator shows a best energy saving performance among the three energy storage refrigerators with largest off-time to on-time ratio of 4.3 and the electrical consumption saving can reach 32%, which is greater than the sum (28%) of the other two kinds of energy storage refrigerators.

  13. Balancing Energy and Performance in Dense Linear System Solvers for Hybrid ARM+GPU platforms

    Directory of Open Access Journals (Sweden)

    Juan P. Silva

    2016-04-01

    Full Text Available The high performance computing community has traditionally focused uniquely on the reduction of execution time, though in the last years, the optimization of energy consumption has become a main issue. A reduction of energy usage without a degradation of performance requires the adoption of energy-efficient hardware platforms accompanied by the development of energy-aware algorithms and computational kernels. The solution of linear systems is a key operation for many scientific and engineering problems. Its relevance has motivated an important amount of work, and consequently, it is possible to find high performance solvers for a wide variety of hardware platforms. In this work, we aim to develop a high performance and energy-efficient linear system solver. In particular, we develop two solvers for a low-power CPU-GPU platform, the NVIDIA Jetson TK1. These solvers implement the Gauss-Huard algorithm yielding an efficient usage of the target hardware as well as an efficient memory access. The experimental evaluation shows that the novel proposal reports important savings in both time and energy-consumption when compared with the state-of-the-art solvers of the platform.

  14. Performance assessment of earth pipe cooling system for low energy buildings in a subtropical climate

    International Nuclear Information System (INIS)

    Ahmed, S.F.; Khan, M.M.K.; Amanullah, M.T.O.; Rasul, M.G.; Hassan, N.M.S.

    2015-01-01

    Highlights: • Earth pipe cooling performance was investigated in a subtropical climate in Australia. • A thermal model was developed using Fluent to assess the cooling performance. • A temperature reduction of around 2 °C was found for the earth pipe cooling system. • Annual energy savings of maximum 866.54 kW (8.82%) was achieved for a 27.23 m"3 room. - Abstract: Energy consumption in heating and cooling around the world has been a major contributor to global warming. Hence, many studies have been aimed at finding new techniques to save and control energy through energy efficient measures. Most of this energy is used in residential, agricultural and commercial buildings. It is therefore important to adopt energy efficiency measures in these buildings through new technologies and novel building designs. These new building designs can be developed by employing various passive cooling systems. Earth pipe cooling is one of these which can assist to save energy without using any customary mechanical units. This paper investigates the earth pipe cooling performance in a hot humid subtropical climate of Rockhampton, Australia. A thermal model is developed using ANSYS Fluent for measuring its performance. Impacts of air velocity, air temperature, relative humidity and soil temperature on room cooling performance are also assessed. A temperature reduction of around 2 °C was found for the system. This temperature reduction contributed to an energy saving of a maximum of 866.54 kW (8.82%) per year for a 27.23 m"3 room.

  15. A SOFTWARE TOOL TO COMPARE MEASURED AND SIMULATED BUILDING ENERGY PERFORMANCE DATA

    Energy Technology Data Exchange (ETDEWEB)

    Maile, Tobias; Bazjanac, Vladimir; O' Donnell, James; Garr, Matthew

    2011-11-01

    Building energy performance is often inadequate when compared to design goals. To link design goals to actual operation one can compare measured with simulated energy performance data. Our previously developed comparison approach is the Energy Performance Comparison Methodology (EPCM), which enables the identification of performance problems based on a comparison of measured and simulated performance data. In context of this method, we developed a software tool that provides graphing and data processing capabilities of the two performance data sets. The software tool called SEE IT (Stanford Energy Efficiency Information Tool) eliminates the need for manual generation of data plots and data reformatting. SEE IT makes the generation of time series, scatter and carpet plots independent of the source of data (measured or simulated) and provides a valuable tool for comparing measurements with simulation results. SEE IT also allows assigning data points on a predefined building object hierarchy and supports different versions of simulated performance data. This paper briefly introduces the EPCM, describes the SEE IT tool and illustrates its use in the context of a building case study.

  16. Utility and performance relative to consumer product energy efficiency standards. Final technical report

    Energy Technology Data Exchange (ETDEWEB)

    Coggins, J.L.

    1979-12-14

    An investigation of the relative utility and performance of nine major household consumer products covered by the Energy Policy and Conservation Act is summarized. The objective was to define the terms utility and performance, to recommend methods for quantifying these two concepts, and to recommend an approach for dealing with utility and performance issues in the energy efficiency standards program. The definitions developed are: performance of a consumer product is the objective measure of how well, with the expected level of consumer input (following the manufacturer's instructions for installation and operation), the product does its intended job; and utility of a consumer product is a subjective measure, based on the consumer's perception, of the capability of the product to satisfy human needs. Quantification is based on test procedures and consumer survey methods which are largely already in use by industry. Utility and performance issues are important in product classification for prescribing energy efficiency standards. The recommended approach to utility and performance issues and classification is: prior to setting standards, evaluate utility and performance issues in the most quantitative way allowed by resources and schedules in order to develop classification guidelines. This approach requires no changes in existing Department of Energy test procedures.

  17. PV (photovoltaics) performance evaluation and simulation-based energy yield prediction for tropical buildings

    International Nuclear Information System (INIS)

    Saber, Esmail M.; Lee, Siew Eang; Manthapuri, Sumanth; Yi, Wang; Deb, Chirag

    2014-01-01

    Air pollution and climate change increased the importance of renewable energy resources like solar energy in the last decades. Rack-mounted PhotoVoltaics (PV) and Building Integrated PhotoVoltaics (BIPV) are the most common photovoltaic systems which convert incident solar radiation on façade or surrounding area to electricity. In this paper the performance of different solar cell types is evaluated for the tropical weather of Singapore. As a case study, on-site measured data of PV systems implemented in a zero energy building in Singapore, is analyzed. Different types of PV systems (silicon wafer and thin film) have been installed on rooftop, façade, car park shelter, railing and etc. The impact of different solar cell generations, arrays environmental conditions (no shading, dappled shading, full shading), orientation (South, North, East or West facing) and inclination (between PV module and horizontal direction) is investigated on performance of modules. In the second stage of research, the whole PV systems in the case study are simulated in EnergyPlus energy simulation software with several PV performance models including Simple, Equivalent one-diode and Sandia. The predicted results by different models are compared with measured data and the validated model is used to provide simulation-based energy yield predictions for wide ranges of scenarios. It has been concluded that orientation of low-slope rooftop PV has negligible impact on annual energy yield but in case of PV external sunshade, east façade and panel slope of 30–40° are the most suitable location and inclination. - Highlights: • Characteristics of PV systems in tropics are analyzed in depth. • The ambiguity toward amorphous panel energy yield in tropics is discussed. • Equivalent-one diode and Sandia models can fairly predict the energy yield. • A general guideline is provided to estimate the energy yield of PV systems in tropics

  18. Energy Efficient Clustering Protocol to Enhance Performance of Heterogeneous Wireless Sensor Network: EECPEP-HWSN

    Directory of Open Access Journals (Sweden)

    Santosh V. Purkar

    2018-01-01

    Full Text Available Heterogeneous wireless sensor network (HWSN fulfills the requirements of researchers in the design of real life application to resolve the issues of unattended problem. But, the main constraint faced by researchers is the energy source available with sensor nodes. To prolong the life of sensor nodes and thus HWSN, it is necessary to design energy efficient operational schemes. One of the most suitable approaches to enhance energy efficiency is the clustering scheme, which enhances the performance parameters of WSN. A novel solution proposed in this article is to design an energy efficient clustering protocol for HWSN, to enhance performance parameters by EECPEP-HWSN. The proposed protocol is designed with three level nodes namely normal, advanced, and super, respectively. In the clustering process, for selection of cluster head we consider different parameters available with sensor nodes at run time that is, initial energy, hop count, and residual energy. This protocol enhances the energy efficiency of HWSN and hence improves energy remaining in the network, stability, lifetime, and hence throughput. It has been found that the proposed protocol outperforms than existing well-known LEACH, DEEC, and SEP with about 188, 150, and 141 percent respectively.

  19. Using integrated control methodology to optimize energy performance for the guest rooms in UAE hospitality sector

    International Nuclear Information System (INIS)

    AlFaris, Fadi; Abu-Hijleh, Bassam; Abdul-Ameer, Alaa

    2016-01-01

    Highlights: • Energy efficiency in 4 and 5 star luxury hotels in the United Arab Emirates. • The normalized energy use index (EUI) ranges between 241.5 and 348.4 kWh/m"2/year for post 2003 hotels. • The normalized energy use index (EUI) ranges between 348.4 and 511.1 kWh/m"2/year for pre 2003 hotels. • Integrated HVAC and lighting control strategies can reduce total energy consumption by up to 31.5%. - Abstract: The hospitality sector is growing rapidly in the UAE and especially in Dubai. As a result, it contributes substantially in the UAE's carbon footprint. This research was conducted to measure, evaluate and increase the energy efficiency in 4 and 5 star luxury hotels in UAE. Energy benchmarking analysis was used to analyze the energy data of 19 hotel buildings to differentiate between usual and best practice of energy performance. Moreover, the normalized energy use index (EUI) kWh/m"2/year has been identified for the best, usual and poor practice hotels. It was found that the normalized EUI ranges between 241.5 kWh/m"2/year or less as a best practice to more than 361.3 kWh/m"2/year of the poor energy practice for the hotels constructed after the year of 2003. Whereas the hotels' energy data showed higher values for those constructed before 2003, as the normalized EUI varies between 348.4 kWh/m"2/year as best practice to more than 511.1 kWh/m"2/year. An integrated control strategy has been employed to improve the energy performance and assess the energy saving for the guestroom. This technique showed that the overall energy performance improvement reached to 31.5% out of entire energy consumption of the hotel including electricity and gas. This reduction resulted in 43.2% savings from the cooling system and 13.2% from the lighting system due to the installing of the integrated control system in the guestrooms.

  20. Effect of Breakfast Omission on Energy Intake and Evening Exercise Performance.

    Science.gov (United States)

    Clayton, David J; Barutcu, Asya; Machin, Claire; Stensel, David J; James, Lewis J

    2015-12-01

    Breakfast omission may reduce daily energy intake. Exercising fasted impairs performance compared with exercising after breakfast, but the effect breakfast omission has on evening exercise performance is unknown. This study assessed the effect of omitting breakfast on evening exercise performance and within-day energy intake. Ten male, habitual breakfast eaters completed two trials in a randomized, counterbalanced order. Subjects arrived at the laboratory in an overnight-fasted state and either consumed or omitted a 733 ± 46 kcal (3095 ± 195 kJ) breakfast. Ad libitum energy intake was assessed at 4.5 h (lunch) and 11 h (dinner). At 9 h, subjects completed a 30-min cycling exercise at approximately 60% VO2peak, followed by a 30-min maximal cycling performance test. Food was not permitted for subjects once they left the laboratory after dinner until 0800 h the following morning. Acylated ghrelin, GLP-1(7-36), glucose, and insulin were assessed at 0, 4.5, and 9 h. Subjective appetite sensations were recorded throughout. Energy intake was 199 ± 151 kcal greater at lunch (P daily energy intake but may impair performance later that day, even after consuming lunch.